Sample records for coagulation

  1. A new approach using coagulation rate constant for evaluation of turbidity removal

    NASA Astrophysics Data System (ADS)

    Al-Sameraiy, Mukheled

    2017-06-01

    Coagulation-flocculation-sedimentation processes for treating three levels of bentonite synthetic turbid water using date seeds (DS) and alum (A) coagulants were investigated in the previous research work. In the current research, the same experimental results were used to adopt a new approach on a basis of using coagulation rate constant as an investigating parameter to identify optimum doses of these coagulants. Moreover, the performance of these coagulants to meet (WHO) turbidity standard was assessed by introducing a new evaluating criterion in terms of critical coagulation rate constant (kc). Coagulation rate constants (k2) were mathematically calculated in second order form of coagulation process for each coagulant. The maximum (k2) values corresponded to doses, which were obviously to be considered as optimum doses. The proposed criterion to assess the performance of coagulation process of these coagulants was based on the mathematical representation of (WHO) turbidity guidelines in second order form of coagulation process stated that (k2) for each coagulant should be ≥ (kc) for each level of synthetic turbid water. For all tested turbid water, DS coagulant could not satisfy it. While, A coagulant could satisfy it. The results obtained in the present research are exactly in agreement with the previous published results in terms of finding optimum doses for each coagulant and assessing their performances. On the whole, it is recommended considering coagulation rate constant to be a new approach as an indicator for investigating optimum doses and critical coagulation rate constant to be a new evaluating criterion to assess coagulants' performance.

  2. Application of alum and chickpea (cicer arietinum) in removing color from leachate

    NASA Astrophysics Data System (ADS)

    Zin, N. S. M.; Awang, N. H.; Akbar, N. A.

    2018-04-01

    Dual coagulant has the potential to improve the coagulation process. In leachate treatment coagulation/flocculation can be used as a main treatment method or as a polishing/tertiary treatment step. Application of natural coagulant as coagulant aids able to increase the formation of floc and the removal ability of the coagulation process. This study was focusing on the ability of dual coagulants made from chemical coagulant (Alum) and natural coagulant (Cicer Arietinum (CA)) in removing colour from leachate. Jar test was carried out to investigate the effect of dose and pH on the removal ability of the dual coagulant. The optimum pH and dose for dual coagulant were obtained at pH 6.0 with dose of Alum at 4 g/L and dose of CA at 0.6 g/L with 94% removal of colour. While the optimum removal of colour for single Alum (4 g/L) and single CA (1.4 g/L) were recorded as 88% and 22%, respectively. The removals obtained using single natural and chemical coagulants were not as good as those obtained by dual coagulant. Thus, addition of CA as a coagulant aid for alum, able to increase the removal of color from leachate and has the potential to be applied as a treatment method for leachate.

  3. Moringa oleifera-mediated coagulation of textile wastewater and its biodegradation using novel consortium-BBA grown on agricultural waste substratum.

    PubMed

    Bedekar, Priyanka A; Bhalkar, Bhumika N; Patil, Swapnil M; Govindwar, Sanjay P

    2016-10-01

    Generation of secondary sludge is a major concern of textile dye removal by coagulation process. Combinatorial coagulation-biodegradation treatment system has been found efficient in degradation of coagulated textile dye sludge. Moringa oleifera seed powder (700 mg L -1 ) was able to coagulate textile dyestuff from real textile wastewater with 98 % color removal. Novel consortium-BBA was found to decolorize coagulated dye sludge. Parameters that significantly affect coagulation process were optimized using response surface methodology. The bench-scale stirred tank reactor (50-L capacity) designed with optimized parameters for coagulation process could efficiently remove 98, 89, 78, and 67 % of American Dye Manufacturer's Institute (ADMI) in four repetitive cycles, respectively. Solid-state fermentation composting reactor designed to treat coagulated dye sludge showed 96 % removal of dye within 10 days. Coagulation of dyes from textile wastewater and degradation of coagulated dye sludge were confirmed by Fourier transform infrared spectroscopy (FTIR) analysis. Cell morphology assay, comet assay, and phytotoxicity confirmed the formation of less toxic products after coagulation and degradation mechanism.

  4. An updated concept of coagulation with clinical implications.

    PubMed

    Romney, Gregory; Glick, Michael

    2009-05-01

    Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.

  5. Simple and rapid methods for purification and characterization of active coagulants from the seeds of Vigna unguiculata and Parkinsonia aculeata.

    PubMed

    Marobhe, N J; Dalhammar, G; Gunaratna, K R

    2007-06-01

    The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.

  6. [Coagulation and adsorption on treating the Yellow River and the impact on chlorine decay during chlorination process].

    PubMed

    Zhan, Xiao; Gao, Bao-yu; Liu, Bin; Xu, Chun-hua; Yue, Qin-yan

    2010-05-01

    Two types of inorganic polymer coagulants, polyferric chloride (PFC) and polyaluminum chloride (PAC), were chosen to treat the Yellow River water. Different dosages were investigated in order to investigate the turbidity, UV24, DOC and permanganate index removal efficiency and their coagulation mechanisms based on the Zeta potentials. The natural organic matter removal by the combination of coagulation and adsorption with powder activated carbon were analyzed based on different coagulant and adsorbent dosages and dosing orders. The effects of combination of coagulation and adsorption on the residual chlorine decay were analyzed. The results showed that the two coagulants had high turbidity removal efficiency ( > 90%). The UV254, DOC, permanganate index removal efficiency were 29.2%, 26.1% and 27.9% respectively for PAC coagulation and were 32.3%, 23.3% and 32.9% respectively for PFC. Electric neutralization played an important role in the PAC coagulation process while both adsorption bridging and electric neutralization performed when PFC was used. The removal percentage of organic matter increased with the increase coagulant and adsorbent. The adsorption after coagulation process gave the better UV254 and DOC removal efficiency than the coagulation after adsorption. The UV254 and DOC removal efficiency were 95.2% and 99.9% for PAC coagulation after adsorption and were 90.1% and 99.9% for PFC coagulation first. But adding powder activated carbon can improve floc settlement performance and maintained persistent disinfection effect.

  7. Overview of the coagulation system.

    PubMed

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-09-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  8. Overview of the coagulation system

    PubMed Central

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-01-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ‘coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same. PMID:25535411

  9. Coagulation behavior and floc characteristics of a novel composite poly-ferric aluminum chloride-polydimethyl diallylammonium chloride coagulant with different OH/(Fe3+ + Al3+) molar ratios.

    PubMed

    Sun, Cuizhen; Qiu, Jinwei; Zhang, Zhibin; Marhaba, Taha F; Zhang, Yanhao

    2016-10-01

    In this paper, flocculating performance and mechanisms of a new composite coagulant, poly-ferric aluminum chloride-polydimethyl diallylammonium chloride (PFAC-PD) with different OH - /(Fe 3+ + Al 3+ ) molar ratios, were investigated for humic acid (HA)-kaolin synthetic wastewater treatment. The impact of OH - /(Fe 3+ + Al 3+ ) molar ratios on the removal efficiencies of turbidity and dissolved organic carbon, specific UV absorbance, coagulation mechanisms and dynamics was explored during the coagulation process using composite coagulants. The coagulation experimental results revealed that the composite coagulants with lower OH - /(Fe 3+ + Al 3+ ) molar ratio exhibited better coagulation efficiency. When OH - /(Fe 3+ + Al 3+ ) molar ratio of the composite coagulant was 1.5, adsorption-bridging played a dominant role in coagulating HA-kaolin synthetic wastewater. The floc growth rate and floc size, increased with increasing OH - /(Fe 3+ + Al 3+ ) molar ratio and the highest peak height of the size distribution was obtained by PFAC-PD with OH - /(Fe 3+ + Al 3+ ) = 1.5. Also, the composite coagulants with higher OH - /(Fe 3+ + Al 3+ ) molar ratio formed more compact flocs, as reflected by the higher fractal dimension value. The flocs coagulated by PFAC-PD with basicity value of 1.0 gave strong strength and good recoverability.

  10. Administration of tissue plasminogen activator without coagulation results in a Chinese population.

    PubMed

    Qin, Xiaoming; Zhao, Songyao; Yin, Liujie; Dou, Hailing; Chen, Jie; Wang, Yifan; Li, Mingzhe; Chen, Ruifang; Fu, Jing; Liu, Wei; Liu, Xin; Yang, Gaiqing; Wang, Runqing; Jia, Xinzhou; Bu, Shufang; Ma, Dongpu; Wang, Baoyu; Li, Shize

    2018-03-01

    Routine coagulation test before intravenous tissue plasminogen activator (tPA) use increases the door to needle time (DNT). We sought to evaluate the safety of tPA use without coagulation results and its impact on prognosis. In our stroke registry, tPA was delivered with coagulation results from December 2015 to April 2016 and without coagulation results from May 2016 to December 2016. Differences of demographics, clinical characteristic, and prognosis between these two groups were analyzed. In addition, logistic regression analysis was conducted to identify predictors for DNT of over 60 min. A total of 201 stroke patients were included in the final analysis. Of these, 81 patients received tPA with coagulation results and 120 patients without coagulation results. Only one (0.8%) patient with abnormal coagulation results met the exclusion criteria of tPA use in patients without coagulation results. The difference of DNT between groups with (mean, 61.7 min) and without (mean, 41.9 min) coagulation results was significant (P = 0.00). The group without coagulation results had a higher rate of favorable 90-day outcome (74.2 vs 70.4%) and lower rates of symptomatic intracranial hemorrhage/nonintracranial hemorrhage (4.9 and 22.2% vs 1.7 and 19.2%) than the group with coagulation results did; these differences were not statistically significant. In multivariate analysis, only tPA use with coagulation results was the predictor for DNT of over 60 min (P = 0.0030, OR = 2.44, 95% CI 1.28-4.65). The present study suggests that tPA could be delivered safely without coagulation results in patients without suspected coagulopathy, and avoiding coagulation tests reduces significantly the DNT interval.

  11. Comparison of single-step and two-step purified coagulants from Moringa oleifera seed for turbidity and DOC removal.

    PubMed

    Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J

    2010-08-01

    The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.

  12. Intraoperative Changes in Blood Coagulation and Thrombelastographic Monitoring in Liver Transplantation

    PubMed Central

    Kang, Yoo Goo; Martin, Douglas J.; Marquez, Jose; Lewis, Jessica H.; Bontempo, Franklin A.; Shaw, Byers W.; Starzl, Thomas E.; Winter, Peter M.

    2010-01-01

    The blood coagulation system of 66 consecutive patients undergoing consecutive liver transplantations was monitored by thrombelastograph and analytic coagulation profile. A poor preoperative coagulation state, decrease in levels of coagulation factors, progressive fibrinolysis, and whole blood clot lysis were observed during the preanhepatic and anhepatic stages of surgery. A further general decrease in coagulation factors and platelets, activation of fibrinolysis, and abrupt decrease in levels of factors V and VIII occurred before and with reperfusion of the homograft. Recovery of blood coagulability began 30–60 min after reperfusion of the graft liver, and coagulability had returned toward baseline values 2 hr after reperfusion. A positive correlation was shown between the variables of thrombelastography and those of the coagulation profile. Thrombelastography was shown to be a reliable and rapid monitoring system. Its use was associated with a 33% reduction of blood and fluid infusion volume, whereas blood coagulability was maintained without an increase in the number of blood product donors. PMID:3896028

  13. Blood coagulation status of small-for-dates and postmature infants.

    PubMed Central

    Perlman, M; Dvilansky, A

    1975-01-01

    In a prospective study of blood coagulation status in small-for-dates and postmature infants there was often evidence of intravascular coagulation. Abnormal coagulation findings correlated with the degree of growth retardation and with the degree of postmaturity. Macroscopical placental infarction and neonatal polycythaemia were associated with coagulation abnormalities; asphyxia, however, was not. Intravascular coagulation may be an additional hazard to small-for-dates and postmature infants. PMID:1170815

  14. Preparation and Evaluation of Titanium-Based Xerogel as a Promising Coagulant for Water/Wastewater Treatment.

    PubMed

    Wang, Xiaomeng; Li, Minghui; Song, Xiaojie; Chen, Zhihao; Wu, Bingdang; Zhang, Shujuan

    2016-09-06

    The nontoxicity of titanium (Ti) and the potential to produce valuable photocatalysts from the final coagulated sludge constitute the main advantages of Ti-based coagulants over conventional ones. However, the low effluent pH and the too-fast hydrolysis limit the wide application of Ti-salt coagulants. Prehydrolysis, to some extent, is helpful to improve the coagulation performance of Ti-salt coagulants. However, the prehydrolyzed polytitanium chloride (PTC) still suffers from narrow applicable dose/pH range. A novel and efficient Ti-based coagulant, denoted as titanium xerogel coagulant (TXC), was successfully prepared by the sol-gel method with TiCl4 as the precursor and acetylacetone as a modifying agent. Compared with TiCl4, a PTC, and a commercial polyferric sulfate, the resulting TXC possessed a larger floc size, better settling property, and wider applicable coagulant dose/pH range. Moreover, the effluent pH after TXC coagulation was not significantly reduced, avoiding the corrosion problem sometimes caused by the low effluent pH. TXC exhibited good coagulation performance for several real wastewaters, especially for the wastewaters of low turbidity. These results demonstrate that gelation was a more effective strategy than prehydrolysis to overcome the inherent weaknesses of Ti salts as a type of promising coagulants.

  15. Assessing blood coagulation status with laser speckle rheology

    PubMed Central

    Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2014-01-01

    We have developed and investigated a novel optical approach, Laser Speckle Rheology (LSR), to evaluate a patient’s coagulation status by measuring the viscoelastic properties of blood during coagulation. In LSR, a blood sample is illuminated with laser light and temporal speckle intensity fluctuations are measured using a high-speed CMOS camera. During blood coagulation, changes in the viscoelastic properties of the clot restrict Brownian displacements of light scattering centers within the sample, altering the rate of speckle intensity fluctuations. As a result, blood coagulation status can be measured by relating the time scale of speckle intensity fluctuations with clinically relevant coagulation metrics including clotting time and fibrinogen content. Our results report a close correlation between coagulation metrics measured using LSR and conventional coagulation results of activated partial thromboplastin time, prothrombin time and functional fibrinogen levels, creating the unique opportunity to evaluate a patient’s coagulation status in real-time at the point of care. PMID:24688816

  16. Real-Time Electrical Impedimetric Monitoring of Blood Coagulation Process under Temperature and Hematocrit Variations Conducted in a Microfluidic Chip

    PubMed Central

    Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming

    2013-01-01

    Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099

  17. Applying the cell-based coagulation model in the management of critical bleeding.

    PubMed

    Ho, K M; Pavey, W

    2017-03-01

    The cell-based coagulation model was proposed 15 years ago, yet has not been applied commonly in the management of critical bleeding. Nevertheless, this alternative model may better explain the physiological basis of current coagulation management during critical bleeding. In this article we describe the limitations of the traditional coagulation protein cascade and standard coagulation tests, and explain the potential advantages of applying the cell-based model in current coagulation management strategies. The cell-based coagulation model builds on the traditional coagulation model and explains many recent clinical observations and research findings related to critical bleeding unexplained by the traditional model, including the encouraging results of using empirical 1:1:1 fresh frozen plasma:platelets:red blood cells transfusion strategy, and the use of viscoelastic and platelet function tests in patients with critical bleeding. From a practical perspective, applying the cell-based coagulation model also explains why new direct oral anticoagulants are effective systemic anticoagulants even without affecting activated partial thromboplastin time or the International Normalized Ratio in a dose-related fashion. The cell-based coagulation model represents the most cohesive scientific framework on which we can understand and manage coagulation during critical bleeding.

  18. Comparison of Moringa stenopetala seed extract as a clean coagulant with Alum and Moringa stenopetala-Alum hybrid coagulant to remove direct dye from Textile Wastewater.

    PubMed

    Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein

    2016-08-01

    In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.

  19. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.

    PubMed

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-03-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.

  20. Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair

    NASA Astrophysics Data System (ADS)

    Zhao, Ming

    Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.

  1. Coagulation monitoring based on blood elastic measurement using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2017-02-01

    Blood coagulation monitoring is important to diagnose hematological diseases and cardiovascular diseases and to predict the risk of bleeding and excessive clotting. In this study, we developed a system to dynamically monitor blood coagulation and quantitatively determine the coagulation function by blood elastic measurement. When blood forms a clot from a liquid, ultrasonic force induces a shear wave, which is detected by optical coherence tomography (OCT). The coagulation of porcine whole blood recalcified by calcium chloride is assessed using the metrics of reaction time, clot formation kinetics and maximum shear modulus. The OCE system can noninvasively monitor the blood coagulation and quantitatively determine the coagulation function.

  2. Blood coagulation profiling in patients using optical thromboelastography (OTEG) (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tripathi, Markandey M.; Tshikudi, Diane M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2016-02-01

    Impaired blood coagulation is often associated with increased postoperative mortality and morbidity in cardiovascular patients. The capability for blood coagulation profiling rapidly at the bedside will enable the timely detection of coagulation defects and open the opportunity for tailoring therapy to correct specific coagulation deficits Optical Thromboelastography (OTEG), is an optical approach to quantify blood coagulation status within minutes using a few drops of whole blood. The goal of the current study is to evaluate the diagnostic accuracy of OTEG for rapid coagulation profiling in patients. In OTEG, temporal laser speckle intensity fluctuations from a drop of clotting blood are measured using a CMOS camera. To quantify coagulation status, the speckle intensity autocorrelation function is measured, the mean square displacement of scattering particles is extracted, and viscoelastic modulus (G), during coagulation is measured via the generalized Stokes-Einstein relation. By quantifying time-resolved changes in G, the coagulation parameters, reaction time (R), clot progression time (K), clot progression rate (Angle), and maximum clot strength (MA) are derived. In this study, the above coagulation parameters were measured using OTEG in 269 patients and compared with standard mechanical Thromboelastography (TEG). Our results showed a strong correlation between OTEG and TEG measurements for all parameters: R-time (R=0.80, p<0.001), clotting time (R=0.78, p<0.001), Angle (R=0.58, p<0.001), and MA (R=0.60, p<0.001). These results demonstrate the unique capability of OTEG for rapid quantification of blood coagulation status to potentially improve clinical capability for identifying impaired coagulation in cardiovascular patients at the point of care.

  3. Particle counter as a tool to control pre-hydrolyzed coagulant dosing and rapid filtration efficiency in a conventional treatment system.

    PubMed

    Gumińska, Jolanta; Kłos, Marcin

    2015-01-01

    Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.

  4. Chemical coagulation of combined sewer overflow: heavy metal removal and treatment optimization.

    PubMed

    El Samrani, A G; Lartiges, B S; Villiéras, F

    2008-02-01

    The coagulation of combined sewer overflow (CSO) was investigated by jar-testing with two commercial coagulants, a ferric chloride solution (CLARFER) and a polyaluminium chloride (WAC HB). CSO samples were collected as a function of time during various wet-weather events from the inlet of Boudonville retention basin, Nancy, France. Jar-tests showed that an efficient turbidity removal can be achieved with both coagulants, though lower optimum dosages and higher re-stabilization concentrations were obtained with the aluminum-based coagulant. Optimum turbidity removal also yielded effective heavy metal elimination. However, the evolution with coagulant dosage of Cu, Zn, Pb, Cr, soluble and suspended solids contents followed various patterns. The removal behaviors can be explained by a selective aggregation of heavy metal carriers present in CSO and a specific interaction between hydrolyzed coagulant species and soluble metals. Stoichiometric relationships were established between optimal coagulant concentration, range of optimal dosing, and CSO conductivity, thus providing useful guidelines to adjust the coagulant demand during the course of CSO events.

  5. Solid colloidal optical wavelength filter

    DOEpatents

    Alvarez, Joseph L.

    1992-01-01

    A solid colloidal optical wavelength filter includes a suspension of spheal particles dispersed in a coagulable medium such as a setting plastic. The filter is formed by suspending spherical particles in a coagulable medium; agitating the particles and coagulable medium to produce an emulsion of particles suspended in the coagulable medium; and allowing the coagulable medium and suspended emulsion of particles to cool.

  6. Application of Cox model in coagulation function in patients with primary liver cancer.

    PubMed

    Guo, Xuan; Chen, Mingwei; Ding, Li; Zhao, Shan; Wang, Yuefei; Kang, Qinjiong; Liu, Yi

    2011-01-01

    To analyze the distribution of coagulation parameters in patients with primary liver cancer; explore the relationship between clinical staging, survival, and coagulation parameters by using Coxproportional hazard model; and provide a parameter for clinical management and prognosis. Coagulation parameters were evaluated in 228 patients with primary liver cancer, 52 patients with common liver disease, and 52 normal healthy controls. The relationship between primary livercancer staging and coagulation parameters wasanalyzed. Follow-up examinations were performed. The Cox proportional hazard model was used to analyze the relationship between coagulationparameters and survival. The changes in the coagulation parameters in patients with primary liver cancer were significantly different from those in normal controls. The effect of the disease on coagulation function became more obvious as the severity of liver cancer increased (p<0.05). The levels of D-dimer, fibrinogen degradation products (FDP), fibrinogen (FIB), and platelets (PLT) were negatively correlated with the long-term survival of patients with advanced liver cancer. The stages of primary liver cancer are associated with coagulation parameters. Coagulation parameters are related to survival and risk factors. Monitoring of coagulation parameters may help ensure better surveillance and treatment for liver cancer patients.

  7. Monopolar soft-mode coagulation using hemostatic forceps for peptic ulcer bleeding.

    PubMed

    Yamasaki, Yasushi; Takenaka, Ryuta; Nunoue, Tomokazu; Kono, Yoshiyasu; Takemoto, Koji; Taira, Akihiko; Tsugeno, Hirofumi; Fujiki, Shigeatsu

    2014-01-01

    Upper gastrointestinal hemorrhage from bleeding peptic ulcer is sometimes difficult to treat by conventional endoscopic methods. Recently, monopolar electrocoagulation using a soft-coagulation system and hemostatic forceps (soft coagulation) has been used to prevent bleeding during endoscopic submucosal dissection. The aim of this study was to assess the safety and efficacy of soft coagulation in the treatment of bleeding peptic ulcer. A total of 39 patients with peptic ulcers were treated using soft coagulation at our hospital between January 2005 and March 2010. Emergency treatment employed an ERBE soft-mode coagulation system using hemostatic forceps. Second-look endoscopy was performed to evaluate the efficacy of prior therapy. Initial hemostasis was defined as accomplished by soft coagulation, with or without other endoscopic therapy prior to soft coagulation. The rate of initial hemostasis, rebleeding, and ultimate hemostasis were retrospectively analyzed. The study subjects were 31 men and 8 women with a mean age of 68.3±13.7 years, with 29 gastric ulcers and 10 duodenal ulcers. Initial hemostasis was achieved in 37 patients (95%). During follow-up, bleeding recurred in two patients, who were retreated with soft coagulation. The monopolar soft coagulation is feasible and safe for treating bleeding peptic ulcers.

  8. Direct observation on the Brownian coagulation of PSL particles through optical microscope in the regime near critical coagulation concentration (CCC).

    PubMed

    Fukasawa, Tomonori; Adachi, Yasuhisa

    2010-04-15

    Microscopic monitoring of floc structure, floc size distribution and the rate of coagulation was carried out for Brownian coagulation of PSL particles. Experiments were designed for the condition of salt concentration that is slightly below critical coagulation concentration (CCC). The density of the solvent was controlled by using deuterium oxide (D(2)O) to avoid sedimentation. Results are summarized as follows: (i) Near CCC, floc restructuring from the beginning stage of coagulation was evidenced, i.e., the ratio of linear triplet is found to be remarkably reduced as compared with the result obtained for the case of rapid coagulation which was implemented under sufficiently high salt concentration. (ii) The increase of fractal dimension from 1.8 in the case of rapid coagulation to 2.2 was confirmed by the analysis of mass balance using size distribution of flocs. This increment resulted in the decrease of effective excluded volume of flocs. (iii) The rate of coagulation was constant until later stage. This result contrasts to the result of rapid coagulation [T. Fukasawa, Y. Adachi, J. Colloid Interface Sci. 304 (2006) 115]. 2010 Elsevier Inc. All rights reserved.

  9. In Vitro Assessment of Nanoparticle Effects on Blood Coagulation.

    PubMed

    Potter, Timothy M; Rodriguez, Jamie C; Neun, Barry W; Ilinskaya, Anna N; Cedrone, Edward; Dobrovolskaia, Marina A

    2018-01-01

    Blood clotting is a complex process which involves both cellular and biochemical components. The key cellular players in the blood clotting process are thrombocytes or platelets. Other cells, including leukocytes and endothelial cells, contribute to clotting by expressing the so-called pro-coagulant activity (PCA) complex on their surface. The biochemical component of blood clotting is represented by the plasma coagulation cascade, which includes plasma proteins also known as coagulation factors. The coordinated interaction between platelets, leukocytes, endothelial cells, and plasma coagulation factors is necessary for maintaining hemostasis and for preventing excessive bleeding. Undesirable activation of all or some of these components may lead to pathological blood coagulation and life-threatening conditions such as consumptive coagulopathy or disseminated intravascular coagulation (DIC). In contrast, unintended inhibition of the coagulation pathways may lead to hemorrhage. Thrombogenicity is the property of a test material to induce blood coagulation by affecting one or more elements of the clotting process. Anticoagulant activity refers to the property of a test material to inhibit coagulation. The tendency to cause platelet aggregation, perturb plasma coagulation, and induce leukocyte PCA can serve as an in vitro measure of a nanomaterial's likelihood to be pro- or anticoagulant in vivo. This chapter describes three procedures for in vitro analyses of platelet aggregation, plasma coagulation time, and activation of leukocyte PCA. Platelet aggregation and plasma coagulation procedures have been described earlier. The revision here includes updated details about nanoparticle sample preparation, selection of nanoparticle concentration for the in vitro study, and updated details about assay controls. The chapter is expanded to describe a method for the leukocyte PCA analysis and case studies demonstrating the performance of these in vitro assays.

  10. In situ coagulation versus pre-coagulation for gravity-driven membrane bioreactor during decentralized sewage treatment: Permeability stabilization, fouling layer formation and biological activity.

    PubMed

    Ding, An; Wang, Jinlong; Lin, Dachao; Tang, Xiaobin; Cheng, Xiaoxiang; Li, Guibai; Ren, Nanqi; Liang, Heng

    2017-12-01

    Gravity-driven membrane filtration systems are promising for decentralized sewage treatment due to their low energy consumption and low maintenance. However, the low stable permeability/flux is currently limiting their wider application. With the ultimate goal of increasing permeability, the aim of this study was to evaluate the effect of coagulation (in situ coagulation and pre-coagulation) on the performance of a gravity-driven membrane bioreactor (GDMBR) during treatment of synthetic sewage. Results show that in situ coagulation significantly increased permeability (more than two-fold); however, no stabilization of permeability occurred over the whole operation, when non-coagulated and pre-coagulated reactors were compared. The high permeability observed was attributed to the accumulated aluminium floc in the reactor, which prevented formation of fluorescent microbial metabolites (aromatic and tryptophan proteins, as well as fulvic acids), and further avoided membrane pore blocking. In addition, the surface porosity of the fouling layer was improved (from 11.2% to 32.4% for non-coagulated and in situ coagulated reactors). The unstable permeability was possibly associated with lower biological processes within the fouling layer. These might include lower adenosine triphosphate (ATP) content and lower fluorescent metabolites from the extracellular polymeric substances (EPS) caused by the accumulated Al (compared with the control). On the other hand, pre-coagulation improved the level of stable permeability compared with the control (80 versus 40 L/m 2 h bar), mainly because pre-coagulation decreased the EPS content and also maintained high ATP content of the fouling layer. In addition, both coagulation processes reduced the total filtration resistance, mainly the hydraulically reversible resistance and cake layer resistance, which could lower the cleaning frequency. Overall, coagulation could greatly increase the removal efficiency and improve the GDMBR permeability, which would make the process suitable for decentralized wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Influence of vegetable coagulant and ripening time on the lipolytic and sensory profile of cheeses made with raw goat milk from Canary breeds.

    PubMed

    Rincón, Arturo A; Pino, Verónica; Fresno, María R; Jiménez-Abizanda, Ana I; Álvarez, Sergio; Ayala, Juan H; Afonso, Ana M

    2017-04-01

    Free fatty acids and sensory profiles were obtained for cheeses made with raw goat milk and vegetable coagulant, derived from the cardoon flower ( Cynara cardunculus), at different ripening times (7 and 20 days). A solid-liquid phase extraction method followed by solid-phase extraction and gas chromatography was used. Profiles were also obtained with cheeses made with commercial coagulant, traditional kid rennet paste, and mixture coagulant (vegetable coagulant-kid rennet). The use of vegetable coagulant and vegetable coagulant-kid rennet is common in traditional Protected Designation of Origin cheeses such as " Queso Flor de Guía" and " Queso Media Flor de Guía" (Spain). Contents of short-chain free fatty acids (7.5-22.5 mmol·kg -1 ), medium-chain free fatty acids (0.4-3.7 mmol·kg -1 ), and long-chain free fatty acids (0.2-2.1 mmol·kg -1 ) varied depending on the coagulant type and the ripening time. Vegetable coagulant cheeses present odour intensity and flavour intensity much higher than commercial coagulant cheeses in the sensory analysis for cheeses obtained with seven days of ripening, but the values decrease when increasing the ripening time. Multivariate analysis allowed us to differentiate cheese samples according to the ripening time when using lipolytic profile and according to the coagulant type using the sensory profile.

  12. Decolorization and COD reduction of dyeing wastewater from a cotton textile mill using thermolysis and coagulation.

    PubMed

    Kumar, Pradeep; Prasad, B; Mishra, I M; Chand, Shri

    2008-05-01

    The decolorization and reduction of COD of dyeing wastewater from a cotton textile mill was conducted using catalytic thermal treatment (thermolysis) accompanied with/without coagulation. Thermolysis in presence of a homogeneous copper sulphate catalyst was found to be the most effective in comparison to other catalysts (FeCl(3), FeSO(4), CuO, ZnO and PAC) used. A maximum reduction of chemical oxygen demand (COD) and color of dyeing wastewater of 66.85% and 71.4%, respectively, was observed with a catalyst concentration of 5 kg/m(3) at pH 8. Commercial alum was found most effective coagulant among various coagulants (aluminum potassium sulphate, PAC, FeCl(3) and FeSO(4)) tested during coagulation operations, resulting in 58.57% COD and 74% color reduction at pH 4 and coagulant dose of 5 kg/m(3). Coagulation of the clear fluid (supernatant) obtained after treatment by thermolysis at the conditions previously used resulted in an overall reduction of 89.91% COD and 94.4% color at pH 4 and a coagulant dose of 2 kg/m(3). The application of thermolysis followed by coagulation, thus, is the most effective treatment method in removing nearly 90% COD and 95% color at a lower dose of coagulant (2 kg/m(3)). The sludge thus produced would contain lower inorganic mass coagulant and, therefore, less amount of inorganic sludge.

  13. Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system.

    PubMed

    Wang, Yili; Guo, Jinlong; Tang, Hongxiao

    2002-01-01

    Factors of pretreatment coagulation/flocculation units were studied using raw water of low temperature and low turbidity. Aluminum sulfate (AS) and selected polyaluminium chlorides (PACls) were all effective in the DAF process when used under favorable conditions of coagulant addition, coagulation, flocculation and flotation units. Compared with the AS coagulant, PACls, at lower dosage, could give the same effective performance even with shorter coagulation/flocculation time or lower recycle ratio during the treatment of cold water. This is attributed to the higher-charged polymeric Al species, and the lower hydrophilic and more compact flocculated flocs of PACl coagulant. Based on results of pilot experiments, the goal of FRD system can be achieved by combining a DAF heterocoagulation reactor with PACl coagulant (F), an efficient flocculation reactor (R), as well as an economical auto-dosing system (D).

  14. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  15. Competition of coagulation sink and source rate: New particle formation in the Pearl River Delta of China

    NASA Astrophysics Data System (ADS)

    Gong, Youguo; Hu, Min; Cheng, Yafang; Su, Hang; Yue, Dingli; Liu, Feng; Wiedensohler, A.; Wang, Zhibin; Kalesse, H.; Liu, Shang; Wu, Zhijun; Xiao, Kaitao; Mi, Puchun; Zhang, Yuanhang

    The coagulation sink and its role in new particle formation are investigated based on data obtained during the PRIDE-PRD2004 campaign at Xinken of Pearl River Delta, China. Analysis of size distributions and mode contributions of the coagulation sink show that the observed higher load of accumulation mode particles impose a significant effect on the coagulation sink and result in higher coagulation sinks at Xinken despite of the lower total particle number compared with other areas. Hence it is concluded that the higher coagulation sink may depress the occurrence frequency of new particle formation events. The strategies targeting at controlling accumulation mode particles may have influences on the frequency of new particle formation events at this area. The factors affecting the coagulation sink are evaluated. The relatively lower ambient relative humidities may weaken the coagulation sink and facilitate the occurrence of new particle formation events during noontime, while the surmise of nucleation and growth involving organic matter may imply an actually higher coagulation sink than expected. These factors have a significant influence on the ultimate fate of the newly formed nuclei and new particle formation. A comparison of event and non-event days indicates that the coagulation sink is not the only decisive factor affecting new particle formation, other factors including the precursor vapors and photochemical activity are none the less important either. Competition of coagulation sink and high source rate leads to the occurrence of new particle formation events at Xinken.

  16. Imaging of blood plasma coagulation at supported lipid membranes.

    PubMed

    Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia

    2011-12-15

    The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Coagulation of Dust Particles in Argon Plasma of RF Discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankelevich, Yu. A.; Olevanov, M. A.; Pal, A. F.

    2008-09-07

    The experiments on coagulation of poly-disperse particles with various size distributions injected into the argon plasma of the magnetron radio-frequency discharge are discussed. The experiments were carried out under the conditions similar to those using dusty plasma for technology applications. Within the created theory the threshold behavior of the coagulation process was explained for the first time, the estimation of the critical particle size for onset of a fast coagulation was made, and the analytical calculation of the coagulation rate of dust particles was performed. The proposed coagulation mechanism makes it possible to describe the typical features of coagulation processesmore » observed in experiments and to explain the effects of attraction and coalescence of highly negatively charged microns size particles.« less

  18. Coagulant recovery and reuse for drinking water treatment.

    PubMed

    Keeley, James; Jarvis, Peter; Smith, Andrea D; Judd, Simon J

    2016-01-01

    Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgin coagulant treatment performance. This study examines the individual and successive separation performance of several novel and existing ferric coagulant recovery purification technologies to attain virgin coagulant purity levels. The new suggested approach of alkali extraction of dissolved organic compounds (DOC) from waterworks sludge prior to acidic solubilisation of ferric coagulants provided the same 14:1 selectivity ratio (874 mg/L Fe vs. 61 mg/L DOC) to the more established size separation using ultrafiltration (1285 mg/L Fe vs. 91 mg/L DOC). Cation exchange Donnan membranes were also examined: while highly selective (2555 mg/L Fe vs. 29 mg/L DOC, 88:1 selectivity), the low pH of the recovered ferric solution impaired subsequent treatment performance. The application of powdered activated carbon (PAC) to ultrafiltration or alkali pre-treated sludge, dosed at 80 mg/mg DOC, reduced recovered ferric DOC contamination to <1 mg/L but in practice, this option would incur significant costs. The treatment performance of the purified recovered coagulants was compared to that of virgin reagent with reference to key water quality parameters. Several PAC-polished recovered coagulants provided the same or improved DOC and turbidity removal as virgin coagulant, as well as demonstrating the potential to reduce disinfection byproducts and regulated metals to levels comparable to that attained from virgin material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Coagulation dynamics of a blood sample by multiple scattering analysis

    NASA Astrophysics Data System (ADS)

    Faivre, Magalie; Peltié, Philippe; Planat-Chrétien, Anne; Cosnier, Marie-Line; Cubizolles, Myriam; Nougier, Christophe; Négrier, Claude; Pouteau, Patrick

    2011-05-01

    We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.

  20. Application of low-mixing energy input for the coagulation process.

    PubMed

    Vadasarukkai, Yamuna S; Gagnon, Graham A

    2015-11-01

    Rapid-mixing tanks with mechanical mixers are a common design used in treatment plants. Yet, the role of such rapid-mixing systems on the effectiveness of the coagulation performance is unclear. This study looked at optimizing the direct energy used in the coagulation process for removal of natural dissolved organic matter (DOM). The role of coagulation mixing intensity (G-value) on total organic carbon (TOC) and turbidity removal was examined for the water types with high organic content, with a specific ultraviolet absorbance (SUVA) of at least 2-2.5 units of m(-1) of absorbance per mg/L. A standard jar test using ferric sulfate coagulant was performed to optimize the chemical condition in coagulation for removal of dissolved organics as well as particles. The jar test analysis at an acidic pH (4.5 ± 0.3) required an iron dose <0.3 mM to arrive at an optimal coagulant concentration and resulted in above 75% of TOC removal. The influence of coagulation mixing on TOC and turbidity removal was evaluated at G varying from 0 to 1500 s(-1) at the optimized coagulant dose and pH conditions for enhanced coagulation. In this study, a combined effective removal of TOC and turbidity was achieved at a low-mixing intensity range of 110 s(-1) < G < 450 s(-1). Coagulation operated at G greater than 450 s(-1) showed negligible improvement in TOC removal. Minimizing energy consumption in enhanced coagulation is feasible at the proposed mixing intensity range (i.e., 110 s(-1) < G < 450 s(-1)), without sacrificing the effectiveness of DOM removal by coagulation. These findings represent an opportunity for energy savings for the water industry without sacrificing quality. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Treatment of waste water by coagulation and flocculation using biomaterials

    NASA Astrophysics Data System (ADS)

    Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh

    2017-11-01

    The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.

  2. Analysis and optimization of coagulation and flocculation process

    NASA Astrophysics Data System (ADS)

    Saritha, V.; Srinivas, N.; Srikanth Vuppala, N. V.

    2017-03-01

    Natural coagulants have been the focus of research of many investigators through the last decade owing to the problems caused by the chemical coagulants. Optimization of process parameters is vital for the effectiveness of coagulation process. In the present study optimization of parameters like pH, dose of coagulant and mixing speed were studied using natural coagulants sago and chitin in comparison with alum. Jar test apparatus was used to perform the coagulation. The results showed that the removal of turbidity was up to 99 % by both alum and chitin at lower doses of coagulant, i.e., 0.1-0.3 g/L, whereas sago has shown a reduction of 70-100 % at doses of 0.1 and 0.2 g/L. The optimum conditions observed for sago were 6 and 7 whereas chitin was stable at all pH ranges, lower coagulant doses, i.e., 0.1-0.3 g/L and mixing speed—rapid mixing at 100 rpm for 10 min and slow mixing 20 rpm for 20 min. Hence, it can be concluded that sago and chitin can be used for treating water even with large seasonal variation in turbidity.

  3. Polyferric sulphate: preparation, characterisation and application in coagulation experiments.

    PubMed

    Zouboulis, A I; Moussas, P A; Vasilakou, F

    2008-07-15

    The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.

  4. A new inorganic-organic composite coagulant, consisting of polyferric sulphate (PFS) and polyacrylamide (PAA).

    PubMed

    Moussas, P A; Zouboulis, A I

    2009-08-01

    Currently, research is focused on the synthesis of new composite coagulants, which are constituted of both inorganic and organic materials. In this paper, the development of relevant reagents was investigated, by combining the inorganic pre-polymerised iron-based coagulant Polyferric Sulphate (PFS) with an organic, non-ionic polymer (Polyacrylamide, PAA) under different PAA/Fe (mg/l) and OH/Fe molar ratios. Moreover, the new reagents were characterised in terms of typical properties, stability and morphological analysis (XRD, FTIR, SEM). Their coagulation performance, when treating low or high turbid kaolin-humic acid suspensions, was also investigated, whereas the applied coagulation mechanisms were discussed by using the Photometric Dispersion Analysis (PDA) analysis. The results show that the new coagulation reagents present improved properties, including increased effective polymer species concentration, and they exhibit very good stability. The respective tests using PDA confirmed that the predominant coagulation mechanism of PFS-PAA is the bridge formation mechanism. Coagulation experiments in low or high turbid kaolin-humic acid suspensions reveal that the novel composite reagent PFS-PAA exhibits better coagulation performance, when compared with simple PFS, in terms of zeta-potential reduction, turbidity and organic matter removal and residual iron concentration.

  5. New models of hemostasis.

    PubMed

    McMichael, Maureen

    2012-05-01

    Hemostasis is an essential protective mechanism that depends on a delicate balance of procoagulant and anticoagulant processes. The waterfall/cascade models of coagulation are useful for understanding several essential steps of coagulation in vitro. These have resulted in the creation of the plasma-based tests used commonly and the ability to identify deficiencies in the extrinsic, intrinsic, and common pathways of coagulation. The model was also essential in elucidating the role of several of the inhibitors of coagulation and is currently used to demonstrate coagulation as it occurs in plasma in a static environment that is devoid of endothelial interactions. The intrinsic pathway originally described by these models does not appear to be essential for in vivo hemostasis but may play a role in pathologic thrombosis. The waterfall/cascade models' lack of cellular elements sets the stage for the cell-based model of coagulation. The cell-based model of blood coagulation, which includes the varied, complicated network of factors necessary for appropriate in vivo coagulation to occur, was the next step in the evolution of our understanding of coagulation. Recently, researchers have focused on real-time, in vivo models of hemostasis and this research reveals unexpected phenomena. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Nanoparticle coagulation in fractionally charged and charge fluctuating dusty plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nunomura, Shota; Kondo, Michio; Shiratani, Masaharu

    2008-08-15

    The kinetics of nanoparticle coagulation has been studied in fractionally charged and charge fluctuating dusty plasmas. The coagulation occurs when the mutual collision frequency among nanoparticles exceeds their charging and decharging/neutralization frequency. Interestingly, the coagulation is suppressed while a fraction (several percent) of nanoparticles are negatively charged in a plasma, in which stochastic charging plays an important role. A model is developed to predict a phase diagram of the coagulation and its suppression.

  7. Comparison of inclined plate sedimentation and dissolved air flotation for the minimisation of subsequent nitrogenous disinfection by-product formation.

    PubMed

    Chu, Wen-Hai; Gao, Nai-Yun; Templeton, Michael R; Yin, Da-Qiang

    2011-04-01

    The formation of disinfection by-products (DBPs), including both nitrogenous disinfection by-products (N-DBPs) and carbonaceous disinfection by-products (C-DBPs), was investigated upon chlorination of water samples following two treatment processes: (i) coagulation-inclined plate sedimentation (IPS)-filtration and (ii) coagulation-dissolved air flotation (DAF)-filtration. The removal of algae, dissolved organic nitrogen (DON), dissolved organic carbon (DOC) and UV(254) by coagulation-DAF-filtration was superior to coagulation-IPS-filtration. On average, 53%, 53% and 31% of DOC, DON and UV(254) were removed by coagulation-DAF-filtration process, which were higher than 47%, 31% and 27% of that by coagulation-IPS-filtration process. Additionally, coagulation-IPS-filtration performed less well at removing the low molecular weight organics than coagulation-DAF-filtration process. The concentrations of chloroform, dichloroacetamide (DCAcAm) and dichloroacetonitrile (DCAN) formed during chlorination after coagulation-DAF-filtration reached their maximum values of 13, 1.5 and 4.7μgL(-1), respectively, and were lower than those after coagulation-IPS-filtration with the maximum detected levels of 17, 2.9 and 6.3μgL(-1). However, the trichloronitromethane (TCNM) concentration after the two processes was similar, suggesting that DON may have less of a contribution to TCNM formation than DCAcAm and DCAN. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. 21 CFR 878.4400 - Electrosurgical cutting and coagulation device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrosurgical cutting and coagulation device and....4400 Electrosurgical cutting and coagulation device and accessories. (a) Identification. An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control...

  9. [The implantation of bipolar coagulation to remove endometriosis foci].

    PubMed

    Sobkiewicz, S; Palatyński, A; Salata, I

    2001-05-01

    The paper compares the results of bipolar coagulation bey means of ERBE ICC 300 diatermy coagulator and WISAP endocoagulator. The results of both types of coagulation were assessed with reference to the changes occurring on peritoneum ligamenti sacro-uterini, Douglas pouch and ovary. The best results of endometriosis foci coagulation were obtained with bipolar ball at 20-30 W; no side effects or feelings of malaise were observed in patients just after the operation or over a longer period of convalescence.

  10. 21 CFR 864.5425 - Multipurpose system for in vitro coagulation studies.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Multipurpose system for in vitro coagulation... Hematology Devices § 864.5425 Multipurpose system for in vitro coagulation studies. (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated...

  11. 21 CFR 864.5425 - Multipurpose system for in vitro coagulation studies.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Multipurpose system for in vitro coagulation... Hematology Devices § 864.5425 Multipurpose system for in vitro coagulation studies. (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated...

  12. Application of response surface methodology (RSM) for optimizing coagulation process of paper recycling wastewater using Ocimum basilicum.

    PubMed

    Mosaddeghi, Mohammad Reza; Pajoum Shariati, Farshid; Vaziri Yazdi, Seyed Ali; Nabi Bidhendi, Gholamreza

    2018-06-21

    The wastewater produced in a pulp and paper industry is one of the most polluted industrial wastewaters, and therefore its treatment requires complex processes. One of the simple and feasible processes in pulp and paper wastewater treatment is coagulation and flocculation. Overusing a chemical coagulant can produce a large volume of sludge and increase costs and health concerns. Therefore, the use of natural and plant-based coagulants has been recently attracted the attention of researchers. One of the advantages of using Ocimum basilicum as a coagulant is a reduction in the amount of chemical coagulant required. In this study, the effect of basil mucilage has been investigated as a plant-based coagulant together with alum for treatment of paper recycling wastewater. Response surface methodology (RSM) was used to optimize the process of chemical coagulation based on a central composite rotatable design (CCRD). Quadratic models for colour reduction and TSS removal with coefficients of determination of R 2 >96 were obtained using the analysis of variance. Under optimal conditions, removal efficiencies of colour and total suspended solids (TSS) were 85% and 82%, respectively.

  13. The Organophosphate Paraoxon and Its Antidote Obidoxime Inhibit Thrombin Activity and Affect Coagulation In Vitro

    PubMed Central

    Golderman, Valery; Shavit-Stein, Efrat; Tamarin, Ilia; Rosman, Yossi; Shrot, Shai; Rosenberg, Nurit

    2016-01-01

    Organophosphates (OPs) are potentially able to affect serine proteases by reacting with their active site. The potential effects of OPs on coagulation factors such as thrombin and on coagulation tests have been only partially characterized and potential interactions with OPs antidotes such as oximes and muscarinic blockers have not been addressed. In the current study, we investigated the in vitro interactions between coagulation, thrombin, the OP paraoxon, and its antidotes obidoxime and atropine. The effects of these substances on thrombin activity were measured in a fluorescent substrate and on coagulation by standard tests. Both paraoxon and obidoxime but not atropine significantly inhibited thrombin activity, and prolonged prothrombin time, thrombin time, and partial thromboplastin time. When paraoxon and obidoxime were combined, a significant synergistic effect was found on both thrombin activity and coagulation tests. In conclusion, paraoxon and obidoxime affect thrombin activity and consequently alter the function of the coagulation system. Similar interactions may be clinically relevant for coagulation pathways in the blood and possibly in the brain. PMID:27689805

  14. A natural coagulant protein from Moringa oleifera: isolation, characterization, and potential use for water treatment

    NASA Astrophysics Data System (ADS)

    Choudhary, Manisha; Neogi, Sudarsan

    2017-10-01

    In developing countries pond water is still widely used for drinking and household purposes, which develops higher turbidity during rainy seasons and requires a large amount of chemical coagulants, and this leads to high cost of treatment. To mitigate this, it is important to find an economical and natural coagulant to treat turbid water. The present study is focused on using a plant based component as a natural coagulant that is sustainable and environment-friendly. This work focuses on the extraction, isolation and purification of a natural coagulant from seed kernels of Moringa oleifera to enhance its turbidity removal efficiency. The determination of themolecular weight of the purified proteins was done using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The active coagulant proteins were isolated using 30-60% and 60-80% saturation of ammonium sulfate. It was observed that proteins with molecular weight less than 36 kDa have superior coagulation activity. Turbidity removal efficiency of these active coagulant proteins was compared with alum. The possibility of using Moringa oleifera seeds as a natural antimicrobial agent was also investigated.

  15. Enhanced coagulation for improving coagulation performance and reducing residual aluminum combining polyaluminum chloride with diatomite.

    PubMed

    Hu, Wenchao; Wu, Chunde

    2016-01-01

    The feasibility of using enhanced coagulation, which combined polyaluminum chloride (PAC) with diatomite for improving coagulation performance and reducing the residual aluminum (Al), was discussed. The effects of PAC and diatomite dosage on the coagulation performance and residual Al were mainly investigated. Results demonstrated that the removal efficiencies of turbidity, dissolved organic carbon (DOC), and UV254 were significantly improved by the enhanced coagulation, compared with PAC coagulation alone. Meaningfully, the five forms of residual Al (total Al (TAl), total dissolved Al (TDAl), dissolved organic Al (DOAl), dissolved monomeric Al (DMAl), and dissolved organic monomeric Al (DOMAl)) all had different degrees of reduction in the presence of diatomite and achieved the lowest concentrations (0.185, 0.06, 0.053, 0.014, and 0 mg L(-1), respectively) at a PAC dose of 15 mg L(-1) and diatomite dose of 40 mg L(-1). In addition, when PAC was used as coagulant, the majority of residual Al existed in dissolved form (about 31.14-70.16%), and the content of DOMAl was small in the DMAl.

  16. Lowering Low-Density Lipoprotein Particles in Plasma Using Dextran Sulphate Co-Precipitates Procoagulant Extracellular Vesicles.

    PubMed

    Wang, Jiong-Wei; Zhang, Ya-Nan; Sze, Siu Kwan; van de Weg, Sander M; Vernooij, Flora; Schoneveld, Arjan H; Tan, Sock-Hwee; Versteeg, Henri H; Timmers, Leo; Lam, Carolyn S P; de Kleijn, Dominique P V

    2017-12-29

    Plasma extracellular vesicles (EVs) are lipid membrane vesicles involved in several biological processes including coagulation. Both coagulation and lipid metabolism are strongly associated with cardiovascular events. Lowering very-low- and low-density lipoprotein ((V)LDL) particles via dextran sulphate LDL apheresis also removes coagulation proteins. It remains unknown, however, how coagulation proteins are removed in apheresis. We hypothesize that plasma EVs that contain high levels of coagulation proteins are concomitantly removed with (V)LDL particles by dextran sulphate apheresis. For this, we precipitated (V)LDL particles from human plasma with dextran sulphate and analyzed the abundance of coagulation proteins and EVs in the precipitate. Coagulation pathway proteins, as demonstrated by proteomics and a bead-based immunoassay, were over-represented in the (V)LDL precipitate. In this precipitate, both bilayer EVs and monolayer (V)LDL particles were observed by electron microscopy. Separation of EVs from (V)LDL particles using density gradient centrifugation revealed that almost all coagulation proteins were present in the EVs and not in the (V)LDL particles. These EVs also showed a strong procoagulant activity. Our study suggests that dextran sulphate used in LDL apheresis may remove procoagulant EVs concomitantly with (V)LDL particles, leading to a loss of coagulation proteins from the blood.

  17. Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review.

    PubMed

    Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko

    2018-01-01

    Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Tissue Factor Coagulant Activity is Regulated by the Plasma Membrane Microenvironment.

    PubMed

    Yu, Yuanjie; Böing, Anita N; Hau, Chi M; Hajji, Najat; Ruf, Wolfram; Sturk, Auguste; Nieuwland, Rienk

    2018-06-01

     Tissue factor (TF) can be present in a non-coagulant and coagulant form. Whether the coagulant activity is affected by the plasma membrane microenvironment is unexplored.  This article studies the presence and coagulant activity of human TF in plasma membrane micro-domains.  Plasma membranes were isolated from human MIA PaCa2 cells, MDA-MB-231 cells and human vascular smooth muscle cells by Percoll gradient ultracentrifugation after cell disruption. Plasma membranes were fractionated by OptiPrep gradient ultracentrifugation, and the presence of TF, flotillin, caveolin, clathrin, protein disulphide isomerase (PDI), TF pathway inhibitor (TFPI) and phosphatidylserine (PS) were determined.  Plasma membranes contain two detergent-resistant membrane (DRM) compartments differing in density and biochemical composition. High-density DRMs (DRM-H) have a density ( ρ ) of 1.15 to 1.20 g/mL and contain clathrin, whereas low-density DRMs (DRM-L) have a density between 1.09 and 1.13 g/mL and do not contain clathrin. Both DRMs contain TF, flotillin and caveolin. PDI is detectable in DRM-H, TFPI is not detectable in either DMR-H or DRM-L and PS is detectable in DRM-L. The DRM-H-associated TF (> 95% of the TF antigen) lacks detectable coagulant activity, whereas the DRM-L-associated TF triggers coagulation. This coagulant activity is inhibited by lactadherin and thus PS-dependent, but seemed insensitive to 16F16, an inhibitor of PDI.  Non-coagulant and coagulant TF are present within different types of DRMs in the plasma membrane, and the composition of these DRMs may affect the TF coagulant activity. Schattauer GmbH Stuttgart.

  19. Influence of a constant and variable magnetic field on the coagulation of human blood in vitro and in vivo

    NASA Technical Reports Server (NTRS)

    Degen, I. L.; Plaksenko, V. Y.

    1974-01-01

    The influence of constant and varying magnetic fields on the coagulation of the blood was studied in experiments performed in vitro and vivo. In the in vitro tests it was found that a constant magnetic field with a strength of 100 or 200 oersteds influences the coagulation of the blood, retarding it in some cases and speeding up the coagulation time in others. In the in vivo studies, both retarding and accelerating effects were likewise observed with respect to the coagulation of the blood, but the nature of the change was a function of the background. A normalizing effect of the magnetic field on the coagulation of the blood was observed.

  20. Dust coagulation. [in interstellar medium observed in stellar envelopes and planetary disks

    NASA Technical Reports Server (NTRS)

    Chokshi, Arati; Tielens, A. G. G. M.; Hollenbach, D.

    1993-01-01

    The microphysics of coagulation between two, colliding, smooth, spherical grains in the elastic limit is investigated, and the criteria for sticking as a function of particle sizes, collision velocities, elastic properties, and binding energy are calculated. Critical relative velocities for coagulation were evaluated as a function of grain sizes for solicate, icy, and carbonaceous grains. It is concluded that efficient coagulation requires coverage of grain cores by an icy grain mantle. In this case, coagulation leads to only a doubling of the mass of a large grain within a dense core lifetime. It is concluded that coagulation can have a dramatic effect on the visible and, particularly, the UV portion of the extinction curve in dense clouds and on their IR spectrum.

  1. Measurement of Blood Coagulation Factor Synthesis in Cultures of Human Hepatocytes.

    PubMed

    Heinz, Stefan; Braspenning, Joris

    2015-01-01

    An important function of the liver is the synthesis and secretion of blood coagulation factors. Within the liver, hepatocytes are involved in the synthesis of most blood coagulation factors, such as fibrinogen, prothrombin, factor V, VII, IX, X, XI, XII, as well as protein C and S, and antithrombin, whereas liver sinusoidal endothelial cells produce factor VIII and von Willebrand factor. Here, we describe methods for the detection and quantification of most blood coagulation factors in hepatocytes in vitro. Hepatocyte cultures indeed provide a valuable tool to study blood coagulation factors. In addition, the generation and expansion of hepatocytes or hepatocyte-like cells may be used in future for cell-based therapies of liver diseases, including blood coagulation factor deficiencies.

  2. A Novel Role for Pro-Coagulant Microvesicles in the Early Host Defense against Streptococcus pyogenes

    PubMed Central

    Oehmcke, Sonja; Westman, Johannes; Malmström, Johan; Mörgelin, Matthias; Olin, Anders I.; Kreikemeyer, Bernd; Herwald, Heiko

    2013-01-01

    Previous studies have shown that stimulation of whole blood or peripheral blood mononuclear cells with bacterial virulence factors results in the sequestration of pro-coagulant microvesicles (MVs). These particles explore their clotting activity via the extrinsic and intrinsic pathway of coagulation; however, their pathophysiological role in infectious diseases remains enigmatic. Here we describe that the interaction of pro-coagulant MVs with bacteria of the species Streptococcus pyogenes is part of the early immune response to the invading pathogen. As shown by negative staining electron microscopy and clotting assays, pro-coagulant MVs bind in the presence of plasma to the bacterial surface. Fibrinogen was identified as a linker that, through binding to the M1 protein of S. pyogenes, allows the opsonization of the bacteria by MVs. Surface plasmon resonance analysis revealed a strong interaction between pro-coagulant MVs and fibrinogen with a KD value in the nanomolar range. When performing a mass-spectrometry-based strategy to determine the protein quantity, a significant up-regulation of the fibrinogen-binding integrins CD18 and CD11b on pro-coagulant MVs was recorded. Finally we show that plasma clots induced by pro-coagulant MVs are able to prevent bacterial dissemination and possess antimicrobial activity. These findings were confirmed by in vivo experiments, as local treatment with pro-coagulant MVs dampens bacterial spreading to other organs and improved survival in an invasive streptococcal mouse model of infection. Taken together, our data implicate that pro-coagulant MVs play an important role in the early response of the innate immune system in infectious diseases. PMID:23935504

  3. Two distinct forms of Factor VIII coagulant protein in human plasma. Cleavage by thrombin, and differences in coagulant activity and association with von Willebrand factor.

    PubMed Central

    Weinstein, M J; Chute, L E

    1984-01-01

    We have characterized Factor VIII coagulant protein, present in normal human plasma, that reacts with a specific human 125I-labeled anti-human VIII:C antigen Fab antibody fragment. Two major Factor VIII coagulant antigen populations were present. The first, approximately 85% of the total antigen, was bound to von Willebrand factor and when tested in a standard one-stage assay had Factor VIII coagulant activity. The second antigenic population, eluting near fibrinogen when plasma was gel filtered, was not bound to von Willebrand protein, did not have Factor VIII coagulant activity unless activated, but did block anti-VIII:C Fab neutralization of clotting activity. The two antigenic populations were separable by cryoprecipitation and agarose gel electrophoresis. Although the two antigenic populations differed in their Factor VIII coagulant activity and in their binding to von Willebrand factor, the principal member of both populations is of mol wt 2.4 X 10(5). Both antigens, when proteolyzed by thrombin, were quickly converted to a 1 X 10(5)-mol wt form in association with the appearance of VIII:C activity. The 1 X 10(5)-mol wt antigen was further slowly degraded to an 8 X 10(4)-mol wt form while Factor VIII coagulant activity declined. These results demonstrate the presence of an inactive Factor VIII coagulant protein in plasma, not associated with von Willebrand factor, that can react with thrombin to yield Factor VIII coagulant activity. Images PMID:6421875

  4. Trihalomethanes (THMs) precursor fractions removal by coagulation and adsorption for bio-treated municipal wastewater: Molecular weight, hydrophobicity/hydrophily and fluorescence.

    PubMed

    Han, Qi; Yan, Han; Zhang, Feng; Xue, Nan; Wang, Yan; Chu, Yongbao; Gao, Baoyu

    2015-10-30

    Due to concerns over health risk of disinfection byproducts (DBPs), removal of trihalomethanes (THMs) precursor from bio-treated wastewater by coagulation and adsorption was investigated in this study. Ultrafiltration (UF) membranes and nonionic resins were applied to fractionate THMs precursor into various molecular weight (MW) fractions and hydrophobic/hydrophilic fractions. Characteristics of coagulated water and adsorbed water were evaluated by the three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy. Results showed that coagulation and adsorption were suitable for removing different hydrophobic/hydrophilic and fluorescent fractions. Coagulation decreased THMs concentration in hydrophobic acids (HoA) fraction from 59 μg/L to 39 μg/L, while the lowest THMs concentration (9 μg/L) in hydrophilic substances (HiS) fraction was obtained in adsorbed water. However, both coagulation and adsorption were ineffective for removing fractions with MW<5 kDa. Although coagulation and adsorption processes could reduce THMs formation, some specific THMs formation potential (STHMFP) in residual dissolved organic matter (DOM) fractions increased in this study. Hydrophobic acid and hydrophilic fractions increased after coagulation treatment, and low MW and hydrophobic fractions increased after adsorption treatment. In addition, active carbon adsorbed more organic matter than coagulant, but brominated disinfection byproducts (Br-DBPs) in adsorbed water turned to the major THMs species after chlorination. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode

    PubMed Central

    Dai, Hongya; Chen, Fei; Yan, Sijing; Ding, Xiaoya; Ma, Dazhao; Wen, Jing; Xu, Die; Zou, Jianzhong

    2017-01-01

    Background The aim of this study was to investigate the feasibility of the application of high-intensity focused ultrasound (HIFU) hat-type ablation mode in in vitro and in vivo models, and to compare the ablation effects of different parameter combinations. Material/Methods HIFU hat-type ablation was performed in isolated bovine liver tissue and in the liver tissue in living rabbits, and the coagulative necrosis for different parameter combinations (plane angles and irradiation order) was investigated. We also analyzed and compared the ablation effects of traditional ablation and hat-type ablation modes. Coagulative necrosis morphology was detected with TTC staining, and the coagulative necrosis volume and energy efficiency factor (EEF) were calculated and compared. Results Coagulative necrosis was observed in all the ablated groups, and the coagulative necrosis volume was much larger than the irradiation area. The coagulative necrosis induced by the hat-type ablation was more regular and controllable than the traditional ablation. The angles between the ablation planes determined the coagulative necrosis morphology, but did not affect the coagulative necrosis volume. Moreover, the irradiation order significantly influenced the coagulative necrosis. Importantly, under certain conditions, hat-type ablation achieved higher efficiency compared with the traditional ablation mode. Conclusions Compared with the traditional ablation mode, HIFU hat-type ablation effectively shortened the irradiation time, reduced the over-accumulation of energy, and increased the HIFU ablation efficiency. PMID:28699626

  6. In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode.

    PubMed

    Dai, Hongya; Chen, Fei; Yan, Sijing; Ding, Xiaoya; Ma, Dazhao; Wen, Jing; Xu, Die; Zou, Jianzhong

    2017-07-12

    BACKGROUND The aim of this study was to investigate the feasibility of the application of high-intensity focused ultrasound (HIFU) hat-type ablation mode in in vitro and in vivo models, and to compare the ablation effects of different parameter combinations. MATERIAL AND METHODS HIFU hat-type ablation was performed in isolated bovine liver tissue and in the liver tissue in living rabbits, and the coagulative necrosis for different parameter combinations (plane angles and irradiation order) was investigated. We also analyzed and compared the ablation effects of traditional ablation and hat-type ablation modes. Coagulative necrosis morphology was detected with TTC staining, and the coagulative necrosis volume and energy efficiency factor (EEF) were calculated and compared. RESULTS Coagulative necrosis was observed in all the ablated groups, and the coagulative necrosis volume was much larger than the irradiation area. The coagulative necrosis induced by the hat-type ablation was more regular and controllable than the traditional ablation. The angles between the ablation planes determined the coagulative necrosis morphology, but did not affect the coagulative necrosis volume. Moreover, the irradiation order significantly influenced the coagulative necrosis. Importantly, under certain conditions, hat-type ablation achieved higher efficiency compared with the traditional ablation mode. CONCLUSIONS Compared with the traditional ablation mode, HIFU hat-type ablation effectively shortened the irradiation time, reduced the over-accumulation of energy, and increased the HIFU ablation efficiency.

  7. ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation

    PubMed Central

    Chen, Da; Zhang, Zhen; Ma, Jilong; Wang, Wei

    2017-01-01

    Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately −217 kHz/cP between the liquid viscosity and the frequency of the resonator. The downshift of the resonant frequency and the viscosity change during the blood coagulation were correlated to monitor the coagulation process. The sigmoidal trend was observed in the frequency response for the blood samples activated by thromboplastin and calcium ions. The coagulation kinetics involving sequential phases of steady reaction, growth and saturation were revealed through the time-dependent frequency profiles. The enzymatic cascade time, the coagulation rate, the coagulation time and the clot degree were provided by fitting the time-frequency curves. The prothrombin times were compared with the results measured by a standard coagulometer and show a good correlation. Thanks to the excellent potential of integration, miniaturization and the availability of direct digital signals, the film bulk acoustic resonator has promising application for both clinical and personal use coagulation testing technologies. PMID:28467374

  8. Improving the Efficiency of Natural Raw Water Pretreatment at Thermal Power Stations

    NASA Astrophysics Data System (ADS)

    Dremicheva, E. S.

    2018-02-01

    In the treatment of make-up water for thermal power stations (TPS) and heat networks, raw water from surface water bodies is used. It contains organic and mineral pollutants in the form of particulates or colloids. Coagulation and flocculation are reagent methods for removing these pollutants from water. Chemicals are used to assist in the formation of large structured flakes that are removed easily from water. The Kuibyshev water reservoir was selected as the object of investigation. Basic physical and chemical properties of the raw water are presented. The application of various coagulating agents, their mixtures in different proportions, and flocculating agents for clarifying the Volga water was examined. The required dose of a coagulant or flocculant was determined based on test coagulation of the treated water. Aluminum sulfate and iron (III) chloride were used a coagulant, and Praestol 2500 (nonionic) as a flocculant. A method of enhancement of coagulation and flocculation by injecting air into the treated water is examined. The results of experimental investigation of the effect of water treatment method on water quality indices, such as alkalinity, pH, iron content, suspended material content, and permanganate value, are presented. It is demonstrated that joint use of ironand aluminum containing coagulation agents brings the coagulation conditions closer to the optimum ones. Aeration does not affect the coagulation process. The methods for supplying air to a clarifier are proposed for practical implementation.

  9. Effectiveness and mechanism of potassium ferrate(VI) preoxidation for algae removal by coagulation.

    PubMed

    Ma, Jun; Liu, Wei

    2002-02-01

    Jar tests were conducted to evaluate the effectiveness of potassium ferrate preoxidation on algae removal by coagulation. Laboratory studies demonstrated that pretreatment with potassium ferrate obviously enhanced the algae removal by coagulation with alum [Al2(SO4)3 . 18H2O]. Algae removal efficiency increased remarkably when the water was pretreated with ferrate. A very short time of preoxidation was enough to achieve substantial algae removal efficiency, and the effectiveness was further increased at a prolonged pretreatment time. Pretreatment with ferrate resulted in a reduction of alum dosage required to cause an efficient coagulation for algae removal. The obvious impact of cell architecture by potassium ferrate was found through scanning electron microscopy. Upon oxidation with ferrate. the cells were inactivated and some intracellular and extracelluar components were released into the water, which may be helpful to the coagulation by their bridging effect. Efficient removal of algae by potassium ferrate preoxidation is believed to be a consequence of several process mechanisms. Ferrate preoxidation inactivated algae, induced the formation of coagulant aid, which are the cellular components secreted by algal cells. The coagulation was also improved by increasing particle concentration in water, because of the formation of the intermediate forms of precipitant iron species during preoxidation. In addition, it was also observed that ferrate preoxidation caused algae agglomerate formation before the addition of coagulant, the subsequent application of alum resulted in further coagulation.

  10. [Effect of ferrate preoxidation on coagulation of Songhua River].

    PubMed

    Li, Chun-juan; Ma, Jun; Liang, Tao

    2008-06-01

    The preoxidation of polluted surface water with ferrate was conducted with respect to its impact on the following coagulation. It can be seen that UV254-absorbance, turbidity and TOC substantially decreased by 36.7%, 80.2%, 31.1%, respectively, after coagulation, without ferrate preoxidation, and by 63.3%, 89.6%, 37.0%, respectively, after coagulation, with ferrate preoxidation. It is noted that NH4+-N concentration is increased by 17% after coagulation with ferrate. This phenomenon can be explained by the fact that organics containing nitrogen in raw water were partly oxidized to inorganic nitrogen by ferrate preoxidation. After coagulation, AOC and AOC/TOC are increased from 998 microg x L(-1) to 1241 microg x L(-1), from 28.4% to 38.7%, respectively, by ferrate preoxidation. AOC-P17/AOC after coagulation is up to 83% with ferrate preoxidation. These suggest that preoxidation with ferrate promoted the biodegradation of organics with substantial increases of AOC, AOC/TOC. The results indicate that the concentration of organics with relative molecular mass (Mr) of 10000-100000 and less than 500 were substantially increased after the raw water was coagulated with ferrate preoxidation, which suggested that some high molecular weight organic substances were broken into smaller ones during ferrate preoxidation. After coagulation, organics of less than Mr = 500 in TOC are increased up to 65.0% with preoxidation from 38.9% without ferrate preoxidation. These oxidation products are biodegradable.

  11. Demonstration of the Coagulation and Diffusion of Homemade Slime Prepared under Acidic Conditions without Borate

    ERIC Educational Resources Information Center

    Isokawa, Naho; Fueda, Kazuki; Miyagawa, Korin; Kanno, Kenichi

    2015-01-01

    Poly(vinyl alcohol) (PVA) precipitates in many kinds of aqueous salt solutions. While sodium sulfate, a coagulant for PVA fiber, precipitates PVA to yield a white rigid gel, coagulation of PVA with aluminum sulfate, a coagulant for water treatment, yields a slime-like viscoelastic fluid. One type of homemade slime is prepared under basic…

  12. Nanoparticles and the blood coagulation system. Part II: safety concerns

    PubMed Central

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2014-01-01

    Nanoparticle interactions with the blood coagulation system can be beneficial or adverse depending on the intended use of a nanomaterial. Nanoparticles can be engineered to be procoagulant or to carry coagulation-initiating factors to treat certain disorders. Likewise, they can be designed to be anticoagulant or to carry anticoagulant drugs to intervene in other pathological conditions in which coagulation is a concern. An overview of the coagulation system was given and a discussion of a desirable interface between this system and engineered nanomaterials was assessed in part I, which was published in the May 2013 issue of Nanomedicine. Unwanted pro- and anti-coagulant properties of nanoparticles represent significant concerns in the field of nanomedicine, and often hamper the development and transition into the clinic of many promising engineered nanocarriers. This part will focus on the undesirable effects of engineered nanomaterials on the blood coagulation system. We will discuss the relationship between the physicochemical properties of nanoparticles (e.g., size, charge and hydrophobicity) that determine their negative effects on the blood coagulation system in order to understand how manipulation of these properties can help to overcome unwanted side effects. PMID:23730696

  13. [Study on the kinetics of organo-clay removing red tide organisms].

    PubMed

    Wu, Ping; Yu, Zhi-ming

    2007-07-01

    The kinetics of red tide organisms (Heterosigma akashiwo and Scrippsiella trochoidea) coagulation with clays modified by dialkyl-polyoxyethenyl quaternary ammonium compound (DPQAC) was studied using spectrophotometer and fluorometry, and the effects of different kinds and concentrations of clays, the second component DPQAC added in clays and pH on the coagulation rate were examined. When using spectrophotometer, the coagulation kinetics of red tide organism coagulation with organo-clays is well fit for the bimolecular reaction model; while using fluorometry, it is fit for the hyperbola model much better. Moreover, the results also prove that using fluorometry can avoid the great change of permeance efficiency caused by clays' sedimentation when using spectrophotometer, which has availably avoided the influence of clays' sedimentation and reflected the essential of algal coagulation and sedimentation well and truly. The results of two studying methods show that the coagulation rate is more rapid in the system of kaolin than in that of bentonite; increasing the concentration of clays and DPQAC and increasing pH all can accelerate coagulation, and among those increasing the concentration of DPQAC is the most efficient way of increasing the removal efficiency and coagulation rate.

  14. Enhanced algae removal by Ti-based coagulant: comparison with conventional Al- and Fe-based coagulants.

    PubMed

    Xu, Jie; Zhao, Yanxia; Gao, Baoyu; Zhao, Qian

    2018-05-01

    The water eutrophication caused by cyanobacteria seasonally proliferates, which is a hot potato to be resolved for water treatment plants. This study firstly investigated coagulation performance of titanium tetrachloride (TiCl 4 ) for Microcystis aeruginosa synthetic water treatment. Results show complete algal cell removal by TiCl 4 coagulation without damage to cell membrane integrity even under harsh conditions; 60 mg/L TiCl 4 was effective in removing the microcystins up to 85%. Furthermore, besides having stronger UV 254 removal capability and the higher removal of fluorescent substances over Al- and Fe-based coagulants, TiCl 4 coagulant required more compact coagulation and sedimentation tanks due to its significantly improved floc growth and sedimentation speed. Meanwhile, its' short hydraulic retention time avoided algal cell breakage and subsequent algal organic matter release. Microcystin concentrations were kept at a low level during sludge storage period, indicating that the TiCl 4 flocs could prevent algal cells from natural lysis. To facilitate water recycling without secondary contamination, the algae-containing sludge after TiCl 4 coagulation ought to be disposed within 12 days at 20 °C and 8 days at 35 °C.

  15. Performance optimization of coagulant/flocculant in the treatment of wastewater from a beverage industry.

    PubMed

    Amuda, O S; Amoo, I A; Ajayi, O O

    2006-02-28

    This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.

  16. Reciprocal coupling of coagulation and innate immunity via neutrophil serine proteases.

    PubMed

    Massberg, Steffen; Grahl, Lenka; von Bruehl, Marie-Luise; Manukyan, Davit; Pfeiler, Susanne; Goosmann, Christian; Brinkmann, Volker; Lorenz, Michael; Bidzhekov, Kiril; Khandagale, Avinash B; Konrad, Ildiko; Kennerknecht, Elisabeth; Reges, Katja; Holdenrieder, Stefan; Braun, Siegmund; Reinhardt, Christoph; Spannagl, Michael; Preissner, Klaus T; Engelmann, Bernd

    2010-08-01

    Blood neutrophils provide the first line of defense against pathogens but have also been implicated in thrombotic processes. This dual function of neutrophils could reflect an evolutionarily conserved association between blood coagulation and antimicrobial defense, although the molecular determinants and in vivo significance of this association remain unclear. Here we show that major microbicidal effectors of neutrophils, the serine proteases neutrophil elastase and cathepsin G, together with externalized nucleosomes, promote coagulation and intravascular thrombus growth in vivo. The serine proteases and extracellular nucleosomes enhance tissue factor- and factor XII-dependent coagulation in a process involving local proteolysis of the coagulation suppressor tissue factor pathway inhibitor. During systemic infection, activation of coagulation fosters compartmentalization of bacteria in liver microvessels and reduces bacterial invasion into tissue. In the absence of a pathogen challenge, neutrophil-derived serine proteases and nucleosomes can contribute to large-vessel thrombosis, the main trigger of myocardial infarction and stroke. The ability of coagulation to suppress pathogen dissemination indicates that microvessel thrombosis represents a physiological tool of host defense.

  17. Interplay between coagulation and vascular inflammation in sickle cell disease

    PubMed Central

    Sparkenbaugh, Erica; Pawlinski, Rafal

    2013-01-01

    Sickle cell disease is the most common inherited hematologic disorder that leads to the irreversible damage of multiple organs. Although sickling of red blood cells and vaso-occlusion are central to the pathophysiology of sickle cell disease the importance of hemolytic anemia and vasculopathy has been recently recognized. Hypercoagulation state is another prominent feature of sickle cell disease and is mediated by activation of both intrinsic and extrinsic coagulation pathways. Growing evidence demonstrates that coagulation may not only contribute to the thrombotic complications, but also to vascular inflammation associated with this disease. This article summarizes the role of vascular inflammation and coagulation activation, discusses potential mechanisms responsible for activation of coagulation and reviews recent data demonstrating the crosstalk between coagulation and vascular inflammation in sickle cell disease. PMID:23593937

  18. Retardation effect of different alcohols on the cement coagulation in polycarboxylate- and naphthalene-based cement admixtures

    NASA Astrophysics Data System (ADS)

    Huang, S. M.; Zhou, F. L.

    2017-12-01

    Alcohol has great potential to delay the coagulation of cement. The effects of alcohol on paste fluidity and normal consistency coagulation time have been studied for polycarboxylate superplasticizer and naphthene cement admixture. Seven alcohols were combined with polycarboxylate superplasticizer and naphthene at a concentration of 0.01-0.09%, respectively, including n-propanol, methanol, sorbitol, ethylene glycol, glycerol, ethanol, and mannitol. The fluidity and normal consistency coagulation time of each cement admixture were measured. The performance of both polycarboxylate superplasticizer and naphthene cement admixtures were compared to develop cement admixture with delayed coagulation.

  19. Distinct composition of bovine milk from Jersey and Holstein-Friesian cows with good, poor, or noncoagulation properties as reflected in protein genetic variants and isoforms.

    PubMed

    Jensen, H B; Poulsen, N A; Andersen, K K; Hammershøj, M; Poulsen, H D; Larsen, L B

    2012-12-01

    The objective of this study was to examine variation in overall milk, protein, and mineral composition of bovine milk in relation to rennet-induced coagulation, with the aim of elucidating the underlying causes of milk with impaired coagulation abilities. On the basis of an initial screening of 892 milk samples from 42 herds with Danish Jersey and Holstein-Friesian cows, a subset of 102 samples was selected to represent milk with good, poor, or noncoagulating properties (i.e., samples that within each breed represented the most extremes in regard to coagulation properties). Milk with good coagulation characteristics was defined as milk forming a strong coagulum based on oscillatory rheology, as indicated by high values for maximum coagulum strength (G'(max)) and curd firming rate (CFR) and a short rennet coagulation time. Poorly coagulating milk formed a weak coagulum, with a low G'(max) and CFR and a long rennet coagulation time. Noncoagulating milk was defined as milk that failed to form a coagulum, having G'(max) and CFR values of zero at measurements taken within 1h after addition of rennet. For both breeds, a lower content of total protein, total casein (CN) and κ-CN, and lower levels of minerals (Ca, P, Mg) were identified in poorly coagulating and noncoagulating milk in comparison with milk with good coagulation properties. Liquid chromatography/electrospray ionization-mass spectrometry revealed the presence of a great variety of genetic variants of the major milk proteins, namely, α(S1)-CN (variants B and C), α(S2)-CN (A), β-CN (A(1), A(2), B, I, and F), κ-CN (A, B, and E), α-lactalbumin (B), and β-lactoglobulin (A, B, and C). In poorly coagulating and noncoagulating milk samples of both breeds, the predominant composite genotype of α(S1)-, β-, and κ-CN was BB-A(2)A(2)-AA, which confirmed a genetic contribution to impaired milk coagulation. Interestingly, subtle variations in posttranslational modification of CN were observed between the coagulation classes in both breeds. Poorly coagulating and noncoagulating milk contained a lower fraction of the least phosphorylated α(S1)-CN form, α(S1)-CN 8P, relative to total α(S1)-CN, along with a lower fraction of glycosylated κ-CN relative to total κ-CN. Thus, apparent variation was observed in the milk and protein composition, in the genetic makeup of the major milk proteins, and in the posttranslational modification level of CN between milk samples with either good or impaired coagulation ability, whereas the composition of poorly coagulating and noncoagulating milk was similar. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. Coagulation Factor Tests

    MedlinePlus

    ... your coagulation factors. Coagulation factors are known by Roman numerals (I, II VIII, etc.) or by name ( ... need this test if you have a family history of bleeding disorders. Most bleeding disorders are inherited . ...

  1. Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.

    PubMed

    Clasen, Stephan; Schmidt, Diethard; Boss, Andreas; Dietz, Klaus; Kröber, Stefan M; Claussen, Claus D; Pereira, Philippe L

    2006-03-01

    To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were placed in a triangular array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted, and the goodness of fit was assessed by using r(2). Coagulation volume, short-axis diameter, and ablation time were dependent on power output and applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter, 8.4 cm; ablation time, 193 min) was induced with a power output of 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, short-axis diameter, and ablation time were 66 cm(3), 4.5 cm, and 19 min, respectively; at 3 cm (100 W), 90 cm(3), 5.2 cm, and 22 min, respectively; at 4 cm (100 W), 132 cm(3), 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm(3), 4.2 cm, and 9 min, respectively; at 3 cm (125 W), 73 cm(3), 4.9 cm, and 12 min, respectively; and at 4 cm (125 W), 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 cm (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation, and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation. Copyright RSNA, 2006.

  2. Optimum coagulant forecasting by modeling jar test experiments using ANNs

    NASA Astrophysics Data System (ADS)

    Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina

    2018-01-01

    Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests but also to predict a proper dosage for coagulant amounts and to project the quality of the output water under real conditions.

  3. Comparison of coagulation pretreatment of produced water from natural gas well by polyaluminium chloride and polyferric sulphate coagulants.

    PubMed

    Zhai, Jun; Huang, Zejin; Rahaman, Md Hasibur; Li, Yue; Mei, Longyue; Ma, Hongpu; Hu, Xuebin; Xiao, Haiwen; Luo, Zhiyong; Wang, Kunping

    2017-05-01

    This study aimed to optimise coagulation pretreatment of the produced water (PW) collected from a natural gas field. Two coagulants, polyferric sulphate (PFS) and polyaluminium chloride (PACl), were applied separately for the organics, suspended solids (SS), and colour removal. Treatment performance at different coagulant dosages, initial pH values, stirring patterns, and the addition of cationic polyacrylamide (PAM) was investigated in jar tests. The optimal coagulation conditions were dosage of PACl 25 g/L or PFS 20 g/L with that of PAM 30 mg/L, initial pH of 11, and fast mixing of 1.5 min (for PACl) or 2 min (for PFS) at 250 rpm followed by slow mixing of 15 min at 50 rpm for both coagulants. PACl performed better than PFS to remove chemical oxygen demand (COD), total organic carbon (TOC), SS, and colour, and achieved a removal efficiency of 90.1%, 89.4%, 99.0%, and 99.9%, respectively, under the optimal condition; while PFS efficiency was 86.1%, 86.1%, 99.0%, and 98.2%, respectively. However, oil removal was higher in PFS coagulation compared to PACl and showed 98.9% and 95.3%, respectively. Biodegradability, ratio of the biological oxygen demand (five-day) (BOD 5 )/COD, of the PW after pretreatment increased from 0.08 to 0.32 for PFS and 0.43 for PACl. Zeta potential (Z-potential) analysis at the optimum coagulant dosage of PACl and PFS suggests that charge neutralisation was the predominant mechanism during coagulation. Better efficiency was observed at higher pH. The addition of PAM and starring pattern had a minor influence on the removal performance of both coagulants. The results suggest that PACl or PFS can be applied for the pretreatment of PW, which can provide substantial removal of carbon, oil, and colour, a necessary first step for subsequent main treatment units such as chemical oxidation or biological treatment.

  4. Adherence and Coagulation Assays in Dabigatran-treated Patients With Atrial Fibrillation

    ClinicalTrials.gov

    2017-09-12

    Atrial Fibrillation; Medication Adherence; Blood Coagulation Tests; Anticoagulants; Circulating, Hemorrhagic Disorder; Drug Effect; Drug Use; Drug Toxicity; Drug Intolerance; Blood Clot; Blood Coagulation Disorder; Laboratory Problem; Bleeding; Thrombosis

  5. A novel protein mixture containing vegetable proteins renders enteral nutrition products non-coagulating after in vitro gastric digestion.

    PubMed

    van den Braak, Claudia C M; Klebach, Marianne; Abrahamse, Evan; Minor, Marcel; Hofman, Zandrie; Knol, Jan; Ludwig, Thomas

    2013-10-01

    Non-coagulation of protein from enteral nutrition (EN) in the stomach is considered to improve gastric emptying and may result in reduced upper gastrointestinal complications such as reflux and aspiration pneumonia. For the development of a new EN protein mixture with reduced gastric coagulation, the coagulating properties of individual proteins, a novel blend of four proteins (P4 protein blend) and commercial EN products were investigated. A semi-dynamic, computer controlled setup was developed to mimic gastric digestion. The coagulation behaviour of 150 ml protein solutions and EN products was investigated. These were heat-treated calcium caseinate, sodium caseinate, whey, soy and pea protein, and the P4 protein blend comprising of the latter four (all solutions 6% w/v protein), four new enteral nutrition product varieties (New Nutrison® .0 or 1.5 kcal/ml, with and without MultiFibre MF6™) based on the P4 protein blend and two other commercially available casein dominant EN products (T1 and T2). Calcium caseinate and sodium caseinate yielded a total wet coagulate of 43.5 ± 0.7 g and 52.7 ± 6.2 g, respectively. Whey, soy, pea and the P4 protein blend did not produce any measurable coagulate. T1 and T2 resulted in a total wet coagulate of 37.5 ± 0.8 g and 57.3 ± 0.8 g, respectively, while all new EN product varieties based on the P4 protein blend did not produce any measurable coagulate. The P4 protein blend renders EN product varieties non-coagulating after in vitro gastric digestion. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  6. Electromagnetic induction sensor for dynamic testing of coagulation process.

    PubMed

    Wang, Zhe; Yu, Yuanhua; Yu, Zhanjiang; Chen, Qimeng

    2018-03-01

    With the increasing demand for coagulation POCT for patients in the surgery department or the ICU, rapid coagulation testing techniques and methods have drawn widespread attention from scholars and businessmen. This paper proposes the use of electromagnetic induction sensor probe for detection of dynamic process causing changes in the blood viscosity and density before and after coagulation based on the damped vibration principle, in order to evaluate the coagulation status. Utilizing the dynamic principle, the differential equation of vibration system comprising elastic support and electromagnetic induction device is established through sensor dynamic modeling. The structural parameters of elastic support are optimized, and the circular sheet spring is designed. Furthermore, harmonic response analysis and vibration fatigue coupling analysis are performed on the elastic support of the sensor by considering the natural frequency of the system, and the electromagnetic induction sensor testing device is set up. Using the device and coagulation reagent, the standard curve for coagulation POCT is plotted, and the blood sample application in clinical patients is established, which are methodologically compared with the imported POCT coagulation analyzer. The results show that the sensor designed in this paper has a first-order natural frequency of 11.368 Hz, which can withstand 5.295 × 10 2 million times of compressions and rebounds. Its correlation with the results of SONOCLOT analyzer reaches 0.996, and the reproducibility 0.002. The electromagnetic induction coagulation testing sensor designed has good elasticity and anti-fatigue, which can meet the accuracy requirement of clinical detection. This study provides the core technology for developing the electromagnetic induction POCT instrument for dynamic testing of coagulation process.

  7. Prediction of coagulation and flocculation processes using ANN models and fuzzy regression.

    PubMed

    Zangooei, Hossein; Delnavaz, Mohammad; Asadollahfardi, Gholamreza

    2016-09-01

    Coagulation and flocculation are two main processes used to integrate colloidal particles into larger particles and are two main stages of primary water treatment. Coagulation and flocculation processes are only needed when colloidal particles are a significant part of the total suspended solid fraction. Our objective was to predict turbidity of water after the coagulation and flocculation process while other parameters such as types and concentrations of coagulants, pH, and influent turbidity of raw water were known. We used a multilayer perceptron (MLP), a radial basis function (RBF) of artificial neural networks (ANNs) and various kinds of fuzzy regression analysis to predict turbidity after the coagulation and flocculation processes. The coagulant used in the pilot plant, which was located in water treatment plant, was poly aluminum chloride. We used existing data, including the type and concentrations of coagulant, pH and influent turbidity, of the raw water because these types of data were available from the pilot plant for simulation and data was collected by the Tehran water authority. The results indicated that ANNs had more ability in simulating the coagulation and flocculation process and predicting turbidity removal with different experimental data than did the fuzzy regression analysis, and may have the ability to reduce the number of jar tests, which are time-consuming and expensive. The MLP neural network proved to be the best network compared to the RBF neural network and fuzzy regression analysis in this study. The MLP neural network can predict the effluent turbidity of the coagulation and the flocculation process with a coefficient of determination (R 2 ) of 0.96 and root mean square error of 0.0106.

  8. Performance and characterization of a new tannin-based coagulant

    NASA Astrophysics Data System (ADS)

    Beltrán-Heredia, J.; Sánchez-Martín, J.; Gómez-Muñoz, C.

    2012-09-01

    Diethanolamine and formaldehyde were employed to cationize tannins from black wattle. This novel coagulant called CDF was functionally characterized in removing sodium dodecylbenzene sulfonate (anionic surfactant) and Palatine Fast Black WAN (azoic dye). Refined tannin-derived commercial coagulants exhibited similar efficiency, while CDF presented higher coagulant ability than alum, a usual coagulant agent. Low doses of CDF (ca. 100 mg L-1) were able to remove more than 70 % of surfactant and more than 85 % of dye (initial pollutant concentration of ca. 100 mg L-1) and it presented no temperature affection and worked at a relatively wide pH range. Surfactant and dye removal responded to the classical coagulant-and-adsorption models, such as Frumkin-Fowler-Guggenheim or Gu and Zhu in the case of surfactant, and Langmuir and Freundlich in the case of dye.

  9. Irregular echogenic foci representing coagulation necrosis: a useful but perhaps under-recognized EUS echo feature of malignant lymph node invasion.

    PubMed

    Bhutani, Manoop S; Saftoiu, Adrian; Chaya, Charles; Gupta, Parantap; Markowitz, Avi B; Willis, Maurice; Kessel, Ivan; Sharma, Gulshan; Zwischenberger, Joseph B

    2009-06-01

    Coagulation necrosis has been described in malignant lymph nodes. Our aim was to determine if coagulation necrosis in mediastinal lymph nodes imaged by EUS could be used as a useful echo feature for predicting malignant invasion. Patients with known or suspected lung cancer who had undergone mediastinal lymph node staging by EUS. Tertiary Care university hospital. An expert endosonographer blinded to the final diagnosis, reviewed the archived digital EUS images of lymph nodes prior to being sampled by FNA. LNs positive for malignancy by FNA were included. The benign group included lymph node images with either negative EUS-FNA or lymph nodes imaged by EUS but not subjected to EUS-FNA, with surgical correlation of their benign nature. 24 patients were included. 8 patients were found to have coagulation necrosis. 7/8 patients had positive result for malignancy by EUS-FNA. One patient determined to have coagulation necrosis had a non-malignant diagnosis indicating a false positive result. 16 patients had no coagulation necrosis. In 6 patients with no coagulation necrosis, the final diagnosis was malignant and in the remaining 10 cases, the final diagnosis was benign. For coagulation necrosis as an echo feature for malignant invasion, sensitivity was 54%, specificity was 91%, positive predictive value was 88%, negative predictive value was 63% and accuracy was 71%. Coagulation necrosis is a useful echo feature for mediastinal lymph node staging by EUS.

  10. Protein corona changes mediated by surface modification of amorphous silica nanoparticles suppress acute toxicity and activation of intrinsic coagulation cascade in mice

    NASA Astrophysics Data System (ADS)

    Yoshida, Tokuyuki; Yoshioka, Yasuo; Morishita, Yuki; Aoyama, Michihiko; Tochigi, Saeko; Hirai, Toshiro; Tanaka, Kota; Nagano, Kazuya; Kamada, Haruhiko; Tsunoda, Shin-ichi; Nabeshi, Hiromi; Yoshikawa, Tomoaki; Higashisaka, Kazuma; Tsutsumi, Yasuo

    2015-06-01

    Recently, nanomaterial-mediated biological effects have been shown to be governed by the interaction of nanomaterials with some kinds of proteins in biological fluids, and the physical characteristics of the nanomaterials determine the extent and type of their interactions with proteins. Here, we examined the relationships between the surface properties of amorphous silica nanoparticles with diameters of 70 nm (nSP70), their interactions with some proteins in biological fluids, and their toxicity in mice after intravenous administration. The surface modification of nSP70 with amino groups (nSP70-N) prevented acute lethality and abnormal activation of the coagulation cascade found in the nSP70-treated group of mice. Since our previous study showed that coagulation factor XII played a role in the nSP70-mediated abnormal activation of the coagulation cascade, we examined the interaction of nSP70 and nSP70-N with coagulation factor XII. Coagulation factor XII bonded to the surface of nSP70 to a greater extent than that observed for nSP70-N, and consequently more activation of coagulation factor XII was observed for nSP70 than for nSP70-N. Collectively, our results suggest that controlling the interaction of nSP70 with blood coagulation factor XII by modifying the surface properties would help to inhibit the nSP70-mediated abnormal activation of the blood coagulation cascade.

  11. RBC Storage Effect on Coagulation, Microparticles and Microchimerism in Critically Ill Patients

    DTIC Science & Technology

    2015-03-01

    Award Number: W81XWH-11-2-0028 TITLE: “RBC Storage Effect on Coagulation, Microparticles and Microchimerism in Critically Ill Patients...27 DEC 2010 - 26 DEC 2015 – 4. TITLE AND SUBTITLE "“RBC Storage Effect on Coagulation, Microparticles and 5a. CONTRACT NUMBER Microchimerism in...15. SUBJECT TERMS RBC storage age; microchimerism; critically ill patients; coagulation; microparticles 16. SECURITY CLASSIFICATION OF: U 17

  12. Hepatic dysfunction contributes to coagulation disturbances in patients undergoing whole body hyperthermia by use of extracorporeal circulation.

    PubMed

    Worel, Nina; Knöbl, Paul; Karanikas, Georgios; Fuchs, Eva-Maria; Bojic, Andja; Brodowicz, Thomas; Jilma, Petra; Zielinski, Christoph C; Köstler, Wolfgang J; Locker, Gottfried J

    2014-09-01

    This phase I study was performed to evaluate coagulation alterations during extracorporeal circulation (ECC) induced whole body hyperthermia (WBHT) in 12 patients with advanced soft tissue sarcomas. To distinguish between effects of normothermic ECC and ECC-WBHT, blood samples were drawn at different time points: at baseline, after 30 min on normothermic ECC, at the end of the heating period, and 24 h and 7 days thereafter. Standard coagulation tests, coagulation factors, thrombelastography,platelets and reticulated platelets, liver enzymes, and scintigraphic platelet imaging were performed. Normothermic ECC resulted in coagulation alterations most likely due to systemic anticoagulation. Induction of hyperthermia caused thrombocytopenia, increased fibrin degradation products,prolonged clotting times, alteration in coagulation factors, and increased liver enzymes. The majority of these effects was most pronounced 24 h after ECC-WBHT. In addition, late liver sequestration of platelets was demonstrated in scintigraphic imaging at that time point. Temporal correlation between hemostatic alterations and elevation in liver enzymes leads to the assumption that liver impairment might play a crucial role in coagulation disturbances observed during ECC-WBHT and thereafter, thus strongly supported by liver sequestration of platelets.Therefore a close monitoring of hepatic derived coagulation alterations in patients undergoing extracorporeal whole body hypothermia is warranted.

  13. Opposite effects of Agrimonia pilosa Ledeb aqueous extracts on blood coagulation function

    PubMed Central

    Yuan, Wufeng; Jiang, Lei; Wang, Huan

    2017-01-01

    Background Agrimonia pilosa Ledeb (APL) has showed anticoagulant and antithrombotic activities in some studies, whereas its actual effects on blood coagulation are still unclear. This study was designed to observe the in vitro effects of APL aqueous extracts on blood coagulation, as well as to investigate the underlying mechanisms. Methods Studies were divided into four groups: 0, 4, 20, and 80 g/L of APL aqueous extracts mixed with plasma or whole blood samples. Clotting time of whole blood, plasma coagulation tests, activities of plasma coagulation factors, plasma calcium ion, platelet aggregation test, and platelet fibrinogen receptor as well as the blood viscosity were measured. Results It was observed that the APL aqueous extracts in 4 g/L significantly prolonged the whole blood clotting time and activated partial thromboplastin time, shortened prothrombin time, decreased activities of coagulation factor VIII, IX and XI, and levels of platelet aggregation and fibrinogen receptor expression. However, coagulation factor VII activity, and blood viscosity were increased after the extracts treatment. And the effects of APL extracts were in a concentration-dependent manner (0–80 g/L). Conclusions The results suggest that APL aqueous extracts have a total anticoagulant activity, whereas they exhibit opposite effects of greater anticoagulant activity than pro-coagulant activity. PMID:28480193

  14. Economic aspects of intraoperative coagulation management targeting higher fibrinogen concentrations during major craniosynostosis surgery.

    PubMed

    Haas, Thorsten; Spielmann, Nelly; Restin, Tanja; Schmidt, Alexander R; Schmugge, Markus; Cushing, Melissa M

    2016-01-01

    Results of a previously published study demonstrated a significant decrease in transfusion requirements and calculated blood loss for pediatric major craniosynostosis surgery, if a ROTEM(®) FIBTEM trigger of <13 mm (early substitution group) was applied as compared to a trigger of <8 mm (conventional group). The aim of this study was a posthoc analysis of the costs for this coagulation management. The total volume as well as the number of units or bags for all transfused blood products and coagulation factors were recorded for each case. The number of laboratory and point-of-care coagulation tests was also analyzed. Total blood product costs were calculated according to the local prices per unit. The total cost for all transfused/administered blood products/coagulation factors per patient was a median of 1023EUR (IQR 850EUR-1058EUR) in the early substitution group as compared to a median of 910EUR (IQR 719EUR-1351EUR) in the conventional group (P = 0.81). No difference in the number of coagulation tests performed was observed. In this study, the use of a higher fibrinogen trigger was not linked to a significant increase in total costs for transfused blood products and coagulation factors, and may offer an economically equivalent approach to coagulation management. © 2015 John Wiley & Sons Ltd.

  15. Characteristics of flocs formed by polymer-only coagulation in water treatment and their impacts on the performance of downstream membrane separation.

    PubMed

    Maeng, Sung Kyu; Timmes, Thomas C; Kim, Hyun-Chul

    2017-10-01

    Two different quaternary amine polymers were examined as primary coagulants for the removal of natural organic matter (NOM) and concurrent production of flocs favorable for downstream membrane separation. The primary issue explored was the relationship between various coagulation conditions on the floc characteristics and the subsequent performance of microfiltration when filtering coagulated NOM. The size distribution and morphological properties of flocs formed through the coagulation of NOM were characterized and the effects of polymer type and dose on these characteristics were also examined. Coagulation of NOM using polydiallyldimethyl-ammonium chloride (pDADMAC) produced looser and less settleable flocs compared to dosing the equivalent amount of epichlorohydrin/dimethylamine (epi/DMA). This was associated with the formation of a relatively denser cake layer on the top of the membrane for the filtration of NOM coagulated with epi/DMA. The charge neutralization coagulation condition with the polymers removed almost all of the fouling tendency that had occurred when filtering raw NOM. The median diameter and the fractal dimension of the flocs produced increased as the zeta potential approached zero, which resulted in the formation of a cake layer that was easily removed from the surface of the membrane.

  16. Coagulant Recovery from Water Treatment Residuals: A Review of Applicable Technologies

    PubMed Central

    Keeley, J.; Jarvis, P.; Judd, S. J.

    2014-01-01

    Conventional water treatment consumes large quantities of coagulant and produces even greater volumes of sludge. Coagulant recovery (CR) presents an opportunity to reduce both the sludge quantities and the costs they incur, by regenerating and purifying coagulant before reuse. Recovery and purification must satisfy stringent potable regulations for harmful contaminants, while remaining competitive with commercial coagulants. These challenges have restricted uptake and lead research towards lower-gain, lower-risk alternatives. This review documents the context in which CR must be considered, before comparing the relative efficacies and bottlenecks of potential technologies, expediting identification of the major knowledge gaps and future research requirements. PMID:26064036

  17. Coagulation cascade and complement system in systemic lupus erythematosus

    PubMed Central

    Liang, Yan; Xie, Shang-Bo; Wu, Chang-Hao; Hu, Yuan; Zhang, Qin; Li, Si; Fan, Yin-Guang; Leng, Rui-Xue; Pan, Hai-Feng; Xiong, Hua-Bao; Ye, Dong-Qing

    2018-01-01

    This study was conducted to (1) characterize coagulation cascade and complement system in systemic lupus erythematosus (SLE); (2) evaluate the associations between coagulation cascade, complement system, inflammatory response and SLE disease severity; (3) test the diagnostic value of a combination of D-dimer and C4 for lupus activity. Transcriptomics, proteomics and metabolomics were performed in 24 SLE patients and 24 healthy controls. The levels of ten coagulations, seven complements and three cytokines were measured in 112 SLE patients. Clinical data were collected from 2025 SLE patients. The analysis of multi-omics data revealed the common links for the components of coagulation cascade and complement system. The results of ELISA showed coagulation cascade and complement system had an interaction effect on SLE disease severity, this effect was pronounced among patients with excess inflammation. The analysis of clinical data revealed a combination of D-dimer and C4 provided good diagnostic performance for lupus activity. This study suggested that coagulation cascade and complement system become ‘partners in crime’, contributing to SLE disease severity and identified the diagnostic value of D-dimer combined with C4for lupus activity. PMID:29599912

  18. Removal of total suspended solid by natural coagulant derived from cassava peel waste

    NASA Astrophysics Data System (ADS)

    Mohd-Asharuddin, S.; Othman, N.; Mohd-Zin, N. S.; Tajarudin, H. A.

    2018-04-01

    The present study was aimed to investigate the performance of starch derived from cassava peel waste as primary coagulant and coagulant aid. Comparable study was also conducted using commercially used aluminium sulfate (alum) as primary coagulant. A series of Jar tests were performed using raw water from Sembrong Barat water treatment plant. It was observed that coagulation test using cassava peel starch (CPS) alone had unappreciable removing ability. However, it was found that combination of alum-CPS successfully achieve up to 90.48% of total suspended solid (TSS) removal under optimized working conditions (pH 9, 7.5mg/L : 100 mg/L of alum : CPS dosage, rapid mixing of 200 rpm for 1 minute; 100 rpm for 2 minutes, slow mixing of 25 rpm for 30 minutes and 30 minutes settling time). This remarks the reduction in alum dosage up to 50% compared to coagulation test using alum alone. Therefore this finding suggesting that CPS can be considered as potential source of sustainable and effective coagulant aid for water treatment especially in developing countries.

  19. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    PubMed

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (< 2 mg/L)--high alkalinity water. Other water samples with higher TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  20. Activation of blood coagulation in cancer: implications for tumour progression

    PubMed Central

    Lima, Luize G.; Monteiro, Robson Q.

    2013-01-01

    Several studies have suggested a role for blood coagulation proteins in tumour progression. Herein, we discuss (1) the activation of the blood clotting cascade in the tumour microenvironment and its impact on primary tumour growth; (2) the intravascular activation of blood coagulation and its impact on tumour metastasis and cancer-associated thrombosis; and (3) antitumour therapies that target blood-coagulation-associated proteins. Expression levels of the clotting initiator protein TF (tissue factor) have been correlated with tumour cell aggressiveness. Simultaneous TF expression and PS (phosphatidylserine) exposure by tumour cells promote the extravascular activation of blood coagulation. The generation of blood coagulation enzymes in the tumour microenvironment may trigger the activation of PARs (protease-activated receptors). In particular, PAR1 and PAR2 have been associated with many aspects of tumour biology. The procoagulant activity of circulating tumour cells favours metastasis, whereas the release of TF-bearing MVs (microvesicles) into the circulation has been correlated with cancer-associated thrombosis. Given the role of coagulation proteins in tumour progression, it has been proposed that they could be targets for the development of new antitumour therapies. PMID:23889169

  1. A simple purification and activity assay of the coagulant protein from Moringa oleifera seed.

    PubMed

    Ghebremichael, Kebreab A; Gunaratna, K R; Henriksson, Hongbin; Brumer, Harry; Dalhammar, Gunnel

    2005-06-01

    Use of extracts from Moringa oleifera (MO) is of great interest for low-cost water treatment. This paper discusses water and salt extraction of a coagulant protein from the seed, purification using ion exchange, its chemical characteristics, coagulation and antimicrobial properties. The coagulant from both extracts is a cationic protein with pI greater than 9.6 and molecular mass less than 6.5 kDa. Mass spectrometric analysis of the purified water extract indicated that it contained at least four homologous proteins, based on MS/MS peptide sequence data. The protein is thermoresistant and remained active after 5h heat treatment at 95 degrees C. The coagulant protein showed both flocculating and antibacterial effects of 1.1--4 log reduction. With samples of high turbidity, the MO extract showed similar coagulation activity as alum. Cecropin A and MO extract were found to have similar flocculation effects for clay and microorganisms. Simple methods for both the purification and assay of MO coagulating proteins are presented, which are necessary for large-scale water treatment applications.

  2. A small amount can make a difference: a prospective human study of the paradoxical coagulation characteristics of hemothorax.

    PubMed

    Smith, W Zachary; Harrison, Hannah B; Salhanick, Marc A; Higgins, Russell A; Ortiz, Alfonso; Olson, John D; Schwacha, Martin G; Harrison, Chantal R; Aydelotte, Jayson D; Stewart, Ronald M; Dent, Daniel L

    2013-12-01

    The evacuated hemothorax has been poorly described because it varies with time, it has been found to be incoagulable, and its potential effect on the coagulation cascade during autotransfusion is largely unknown. This is a prospective descriptive study of adult patients with traumatic chest injury necessitating tube thoracostomy. Pleural and venous samples were analyzed for coagulation, hematology, and electrolytes at 1 to 4 hours after drainage. Pleural samples were also analyzed for their effect on the coagulation cascade via mixing studies. Thirty-four subjects were enrolled with a traumatic hemothorax. The following measured coagulation factors were significantly depleted compared with venous blood: international normalized ratio (>9 vs 1.1) (P < .001) and activated partial thromboplastin time (aPTT) (>180 vs 24.5 seconds) (P < .001). Mixing studies showed a dose-dependent increase in coagulation dilutions through 1:8 (P < .05). An evacuated hemothorax does not vary in composition significantly with time and is incoagulable alone. Mixing studies with hemothorax plasma increased coagulation, raising safety concerns. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Influential factors of formation kinetics of flocs produced by water treatment coagulants.

    PubMed

    Wu, Chunde; Wang, Lin; Hu, Bing; Ye, Jian

    2013-05-01

    The growth rate and size of floc formation is of great importance in water treatment especially in coagulation process. The floc formation kinetics and the coagulation efficiency of synthetic water were investigated by using an on-line continuous optical photometric dispersion analyze and the analysis of water quality. Experimental conditions such as alum dosage, pH value for coagulation, stirring intensity and initial turbidity were extensively examined. The photometric dispersion analyze results showed that coagulation of kaolin suspensions with two coagulants (alum and polyaluminium chloride) could be taken as a two-phase process: slow and rapid growth periods. Operating conditions with higher coagulant doses, appropriate pH and average shear rate might be particularly advantageous. The rate of overall floc growth was mainly determined by a combination of hydraulic and water quality conditions such as pH and turbidity. The measurement of zeta potential indicates that polyaluminium chloride exhibited higher charge-neutralizing ability than alum and achieved lower turbidities than alum for equivalent Al dosages. Under the same operating conditions, the alum showed a higher grow rate, but with smaller floc size.

  4. Colloids removal from water resources using natural coagulant: Acacia auriculiformis

    NASA Astrophysics Data System (ADS)

    Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.

    2017-09-01

    All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.

  5. Coagulation disorders in dogs with hepatic disease.

    PubMed

    Prins, M; Schellens, C J M M; van Leeuwen, M W; Rothuizen, J; Teske, E

    2010-08-01

    Liver disease has been associated with abnormalities in haemostasis. In this study, coagulation times, platelet counts, platelet activity parameters, activities of individual coagulation factors, D-dimers, antithrombin (AT) and protein C activity were measured in 42 dogs with histologically confirmed liver disease. Outcome was correlated with histological diagnosis. One or more coagulation abnormalities were present in 57% of dogs with hepatic disease. Activated partial thromboplastin time was significantly prolonged in dogs with chronic hepatitis (CH), with or without cirrhosis. Mean platelet numbers, AT and factor IX activity were significantly lower in dogs with CH plus cirrhosis, compared to dogs with other hepatopathies. D-dimers were not significantly increased in any group. Only three dogs, all with different histological diagnoses, satisfied the criteria for disseminated intravascular coagulation (DIC). Haemostatic abnormalities were primarily seen in dogs with cirrhosis and this may be due to reduced synthesis rather than increased consumption of coagulation factors. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  6. Application of a combined process of moving-bed biofilm reactor (MBBR) and chemical coagulation for dyeing wastewater treatment.

    PubMed

    Shin, D H; Shin, W S; Kim, Y H; Han, Myung Ho; Choi, S J

    2006-01-01

    A combined process consisted of a Moving-Bed Biofilm Reactor (MBBR) and chemical coagulation was investigated for textile wastewater treatment. The pilot scale MBBR system is composed of three MBBRs (anaerobic, aerobic-1 and aerobic-2 in series), each reactor was filled with 20% (v/v) of polyurethane-activated carbon (PU-AC) carrier for biological treatment followed by chemical coagulation with FeCl2. ln the MBBR process, 85% of COD and 70% of color (influent COD = 807.5 mg/L and color = 3,400 PtCo unit) were removed using relatively low MLSS concentration and short hydraulic retention time (HRT = 44 hr). The biologically treated dyeing wastewater was subjected to chemical coagulation. After coagulation with FeCl2, 95% of COD and 97% of color were removed overall. The combined process of MBBR and chemical coagulation has promising potential for dyeing wastewater treatment.

  7. Performance of ultrafiltration membrane process combined with coagulation/sedimentation.

    PubMed

    Jang, N Y; Watanabe, Y; Minegishi, S

    2005-01-01

    Effects of coagulation/sedimentation as a pre-treatment on the dead-end ultrafiltration (UF) membrane process were studied in terms of membrane fouling and removal efficiency of natural dissolved organic matter, using Chitose River water. Two types of experiment were carried out. One was a bench scale membrane filtration with jar-test and the other was membrane filtration pilot plant combined with the Jet Mixed Separator (JMS) as a pre-coagulation/sedimentation unit. In the bench scale experiment, the effects of coagulant dosage, pH and membrane operating pressure on the membrane fouling and removal efficiency of natural dissolved organic matter were investigated. In the pilot plant experiment, we also investigated the effect of pre-coagulation/sedimentation on the membrane fouling and the removal efficiency of natural dissolved organic matter. Coagulation/sedimentation prior to membrane filtration process controlled the membrane fouling and increased the removal efficiency of natural dissolved organic matter.

  8. Development of a magnetic coagulant based on Moringa oleifera seed extract for water treatment.

    PubMed

    Santos, Tássia R T; Silva, Marcela F; Nishi, Leticia; Vieira, Angélica M S; Fagundes-Klen, Márcia R; Andrade, Murilo B; Vieira, Marcelo F; Bergamasco, Rosângela

    2016-04-01

    In this work, to evaluate the effectiveness of the coagulation/flocculation using a natural coagulant, using Moringa oleifera Lam functionalized with magnetic iron oxide nanoparticles, producing flakes that are attracted by an external magnetic field, thereby allowing a fast settling and separation of the clarified liquid, is proposed. The removal efficiency of the parameters, apparent color, turbidity, and compounds with UV254nm absorption, was evaluated. The magnetic functionalized M. oleifera Lam coagulant could effectively remove 90 % of turbidity, 85 % of apparent color, and 50 % for the compounds with absorption at UV254nm, in surface waters under the influence of an external magnetic field within 30 min. It was found that the coagulation/flocculation treatment using magnetic functionalized M. oleifera Lam coagulant was able to reduce the values of the physico-chemical parameters evaluated with reduced settling time.

  9. Characterisation of medical-waste sterilisation-plant wastewater and a preliminary study of coagulation-flocculation treatment options.

    PubMed

    Ozkan, O; Mihçiokur, H; Azgin, S T; Ozdemir, O

    2010-01-01

    Wastewater from a medical-waste sterilisation plant (MWSP) contains unique pollutants and requires on-site treatment to prevent contamination of the municipal sewage system and receiving water bodies. Therefore, to meet the prescribed discharge standards and comply with the legal regulations, pre-treatment must be applied to MWSP wastewater. In this study, the capabilities of coagulation-flocculation processes were investigated for MWSP wastewater treatment. Processes using ferric chloride, ferrous sulfate and aluminium sulfate as coagulants were characterised. During the coagulation experiments, seven different coagulant dosages and four different pH values were evaluated to determine the optimum coagulant dosage and pH value. The highest removal efficiency of chemical oxygen demand (COD) was obtained using 300 mg/L of ferric chloride at pH 10. A COD removal of about 60% as well as considerable reductions in the amounts of suspended solids, nitrogen and phosphorus were realised.

  10. The occurrence of noncoagulating milk and the association of bovine milk coagulation properties with genetic variants of the caseins in 3 Scandinavian dairy breeds.

    PubMed

    Poulsen, N A; Bertelsen, H P; Jensen, H B; Gustavsson, F; Glantz, M; Månsson, H Lindmark; Andrén, A; Paulsson, M; Bendixen, C; Buitenhuis, A J; Larsen, L B

    2013-08-01

    Substantial variation in milk coagulation properties has been observed among dairy cows. Consequently, raw milk from individual cows and breeds exhibits distinct coagulation capacities that potentially affect the technological properties and milk processing into cheese. This variation is largely influenced by protein composition, which is in turn affected by underlying genetic polymorphisms in the major milk proteins. In this study, we conducted a large screening on 3 major Scandinavian breeds to resolve the variation in milk coagulation traits and the frequency of milk with impaired coagulation properties (noncoagulation). In total, individual coagulation properties were measured on morning milk collected from 1,299 Danish Holstein (DH), Danish Jersey (DJ), and Swedish Red (SR) cows. The 3 breeds demonstrated notable interbreed differences in coagulation properties, with DJ cows exhibiting superior coagulation compared with the other 2 breeds. In addition, milk samples from 2% of DH and 16% of SR cows were classified as noncoagulating. Furthermore, the cows were genotyped for major genetic variants in the αS1- (CSN1S1), β- (CSN2), and κ-casein (CSN3) genes, revealing distinct differences in variant frequencies among breeds. Allele I of CSN2, which had not formerly been screened in such a high number of cows in these Scandinavian breeds, showed a frequency around 7% in DH and DJ, but was not detected in SR. Genetic polymorphisms were significantly associated with curd firming rate and rennet coagulation time. Thus, CSN1S1 C, CSN2 B, and CSN3 B positively affected milk coagulation, whereas CSN2 A(2), in particular, had a negative effect. In addition to the influence of individual casein genes, the effects of CSN1S1-CSN2-CSN3 composite genotypes were also examined, and revealed strong associations in all breeds, which more or less reflected the single gene results. Overall, milk coagulation is under the influence of additive genetic variation. Optimal milk for future cheese production can be ensured by monitoring the frequency of unfavorable variants and thus preventing an increase in the number of cows producing milk with impaired coagulation. Selective breeding for variants associated with superior milk coagulation can potentially increase raw milk quality and cheese yield in all 3 Scandinavian breeds. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Removal of inorganic mercury and methylmercury from surface waters following coagulation of dissolved organic matter with metal-based salts

    USGS Publications Warehouse

    Henneberry, Y.K.; Kraus, T.E.C.; Fleck, J.A.; Krabbenhoft, D.P.; Bachand, P.M.; Horwath, W.R.

    2011-01-01

    The presence of inorganic mercury (IHg) and methylmercury (MeHg) in surface waters is a health concern worldwide. This study assessed the removal potential use of metal-based coagulants as a means to remove both dissolved IHg and MeHg from natural waters and provides information regarding the importance of Hg associations with the dissolved organic matter (DOM) fraction and metal hydroxides. Previous research indicated coagulants were not effective at removing Hg from solution; however these studies used high concentrations of Hg and did not reflect naturally occurring concentrations of Hg. In this study, water collected from an agricultural drain in the Sacramento-San Joaquin Delta was filtered to isolate the dissolved organic matter (DOM) fraction. The DOM was then treated with a range of coagulant doses to determine the efficacy of removing all forms of Hg from solution. Three industrial-grade coagulants were tested: ferric chloride, ferric sulfate, and polyaluminum chloride. Coagulation removed up to 85% of DOM from solution. In the absence of DOM, all three coagulants released IHg into solution, however in the presence of DOM the coagulants removed up to 97% of IHg and 80% of MeHg. Results suggest that the removal of Hg is mediated by DOM-coagulant interactions. There was a preferential association of IHg with the more aromatic, higher molecular weight fraction of DOM but no such relationship was found for MeHg. This study offers new fundamental insights regarding large-scale removal of Hg at environmentally relevant regarding large-scale removal of Hg at environmentally relevant concentrations.

  12. Coagulation chemistries for silica removal from cooling tower water.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants deliveredmore » promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.« less

  13. Improved perfusion system for bipolar radiofrequency ablation of liver: preliminary findings from a computer modeling study.

    PubMed

    Berjano, Enrique J; Burdío, Fernando; Navarro, Ana C; Burdío, José M; Güemes, Antonio; Aldana, Oscar; Ros, Paloma; Sousa, Ramón; Lozano, Ricardo; Tejero, Eloy; de Gregorio, Miguel A

    2006-10-01

    Current systems for radiofrequency ablation of liver tumors are unable to consistently treat tumors larger than 3 cm in diameter with a single electrode in a single application. One of the strategies for enlarging coagulation zone dimensions is to infuse saline solutions into the tissue through the active electrodes. Nevertheless, the uncontrolled and undirected diffusion of boiling saline into the tissue has been associated with irregular coagulation zones and severe complications, mainly due to reflux of saline along the electrode path. In order to improve the perfusion bipolar ablation method, we hypothesized that the creation of small monopolar coagulation zones adjacent to the bipolar electrodes and previous to the saline infusion would create preferential paths for the saline to concentrate on the targeted coagulation zone. Firstly, we conducted ex vivo experiments in order to characterize the monopolar coagulation zones. We observed that they are practically impermeable to the infused saline. On the basis of this finding, we built theoretical models and conducted computer simulations to assess the feasibility of our hypothesis. Temperature distributions during bipolar ablations with and without previous monopolar coagulation zones were obtained. The results showed that in the case of monopolar coagulation zones the temperature of the tissue took longer to reach 100 degrees C. Since this temperature value is related to rise of impedance, and the time necessary for this process is directly related to the volume of the coagulation zone, our results suggest that monopolar sealing would allow larger coagulation zones to be created. Future experimental studies should confirm this benefit.

  14. Emergent self-similarity of cluster coagulation

    NASA Astrophysics Data System (ADS)

    Pushkin, Dmtiri O.

    A wide variety of nonequilibrium processes, such as coagulation of colloidal particles, aggregation of bacteria into colonies, coalescence of rain drops, bond formation between polymerization sites, and formation of planetesimals, fall under the rubric of cluster coagulation. We predict emergence of self-similar behavior in such systems when they are 'forced' by an external source of the smallest particles. The corresponding self-similar coagulation spectra prove to be power laws. Starting from the classical Smoluchowski coagulation equation, we identify the conditions required for emergence of self-similarity and show that the power-law exponent value for a particular coagulation mechanism depends on the homogeneity index of the corresponding coagulation kernel only. Next, we consider the current wave of mergers of large American banks as an 'unorthodox' application of coagulation theory. We predict that the bank size distribution has propensity to become a power law, and verify our prediction in a statistical study of the available economical data. We conclude this chapter by discussing economically significant phenomenon of capital condensation and predicting emergence of power-law distributions in other economical and social data. Finally, we turn to apparent semblance between cluster coagulation and turbulence and conclude that it is not accidental: both of these processes are instances of nonlinear cascades. This class of processes also includes river network formation models, certain force-chain models in granular mechanics, fragmentation due to collisional cascades, percolation, and growing random networks. We characterize a particular cascade by three indicies and show that the resulting power-law spectrum exponent depends on the indicies values only. The ensuing algebraic formula is remarkable for its simplicity.

  15. Retrospective analysis of the incidence of epidural haematoma in patients with epidural catheters and abnormal coagulation parameters.

    PubMed

    Gulur, P; Tsui, B; Pathak, R; Koury, K M; Lee, H

    2015-05-01

    Epidural haematoma is a rare but potentially catastrophic complication associated with epidural catheterization. The times of insertion and removal of epidural catheters are high-risk periods for epidural haematoma formation, especially with abnormal coagulation parameters. There is a lack of data on the incidence of epidural haematoma in patients with abnormal coagulation parameters. A retrospective analysis was undertaken from 2002 to 2009 on patients with an epidural catheter. Queries were performed on the coagulation parameters for the dates of placement and removal of the catheters and on all documented epidural haematoma cases. During the study period, 11 600 epidural catheters were placed. In the setting of abnormal coagulation parameters, 278 (2.4%) epidural catheters were placed and 351 (3%) were removed. Two epidural haematomas occurred; both patients had epidural catheters and spinal drains placed for vascular procedures with abnormal coagulation parameters after operatation. The haematomas occurred after removal of the catheters. Based on our study, the incidence of epidural haematoma in patients with abnormal coagulation parameters is 1 in 315 patients, with the lower limit of the 95% confidence interval at 87 and the upper limit at 2597. The risk of epidural haematoma is clearly elevated with abnormal coagulation parameters. Our data suggest that as the incidence of epidural haematoma with neuraxial access in patients with abnormal coagulation is not 100%, individual risk-benefit evaluations are warranted. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Short communication: Prediction of milk coagulation and acidity traits in Mediterranean buffalo milk using Fourier-transform mid-infrared spectroscopy.

    PubMed

    Manuelian, C L; Visentin, G; Boselli, C; Giangolini, G; Cassandro, M; De Marchi, M

    2017-09-01

    Milk coagulation and acidity traits are important factors to inform the cheesemaking process. Those traits have been deeply studied in bovine milk, whereas scarce information is available for buffalo milk. However, the dairy industry is interested in a method to determine milk coagulation and acidity features quickly and in a cost-effective manner, which could be provided by Fourier-transform mid-infrared (FT-MIR) spectroscopy. The aim of this study was to evaluate the potential of FT-MIR to predict coagulation and acidity traits of Mediterranean buffalo milk. A total of 654 records from 36 herds located in central Italy with information on milk yield, somatic cell score, milk chemical composition, milk acidity [pH, titratable acidity (TA)], and milk coagulation properties (rennet coagulation time, curd firming time, and curd firmness) were available for statistical analysis. Reference measures of milk acidity and coagulation properties were matched with milk spectral information, and FT-MIR prediction models were built using partial least squares regression. The data set was divided into a calibration set (75%) and a validation set (25%). The capacity of FT-MIR spectroscopy to correctly classify milk samples based on their renneting ability was evaluated by a canonical discriminant analysis. Average values for milk coagulation traits were 13.32 min, 3.24 min, and 39.27 mm for rennet coagulation time, curd firming time, and curd firmness, respectively. Milk acidity traits averaged 6.66 (pH) and 7.22 Soxhlet-Henkel degrees/100 mL (TA). All milk coagulation and acidity traits, except for pH, had high variability (17 to 46%). Prediction models of coagulation traits were moderately to scarcely accurate, whereas the coefficients of determination of external validation were 0.76 and 0.66 for pH and TA, respectively. Canonical discriminant analysis indicated that information on milk coagulating ability is present in the MIR spectra, and the model correctly classified as noncoagulating the 91.57 and 67.86% of milk samples in the calibration and validation sets, respectively. In conclusion, our results can be relevant to the dairy industry to classify buffalo milk samples before processing. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. New lab-made coagulant based on Schinopsis balansae tannin extract: synthesis optimization and preliminary tests on refractory water pollutants

    NASA Astrophysics Data System (ADS)

    Sánchez-Martín, J.; Beltrán-Heredia, J.; Coco-Rivero, B.

    2014-09-01

    Quebracho colorado tannin extract was used as a coagulant raw material for water and wastewater treatment. The chemical synthesis follows a Mannich reaction mechanism and provides a fully working coagulant that can remove several pollutants from water. This paper addresses the optimization of such synthesis and confirms the feasibility of the coagulant by testing it in a preliminary screening for the elimination of dyes and detergents. The optimum combination of reagents was 6.81 g of diethanolamine (DEA) and 2.78 g of formaldehyde (F) per g of tannin extract. So obtained coagulant was succesfully tested on the removal of 9 dyes and 8 detergents.

  18. Review of Coagulation Technology for Removal of Arsenic: Case of Chile

    PubMed Central

    2006-01-01

    Coagulation technology has been used since 1970 in northern Chile for removing arsenic from drinking-water. This experience suggests that coagulation is an effective technology for the removal of arsenic. It is currently possible to reduce arsenic from 400 μg/L to 10 μg/L at a rate of 500 L/sec, assuming pH, oxidizing and coagulation agents are strictly controlled. The Chilean experience with the removal of arsenic demonstrates that the water matrix dictates the selection of the arsenic-removal process. This paper presents a summary of the process, concepts, and operational considerations for the use of coagulation technology for removal of arsenic in Chile. PMID:17366767

  19. Effect of Hemodilution on Coagulation and Recombinant Factor VIIa Efficacy in Human Blood In Vitro

    DTIC Science & Technology

    2011-11-01

    thrombasthenia.12 In trauma, when a blood vessel is injured, tissue factor on subendothelial pericytes is exposed and binds to endogenous FVII ...a more complex effect on coagulation than simply dilution of any single coagulation factor like FVII or fibrinogen (Fig. 1). It is interesting to note...ORIGINAL ARTICLE Effect of Hemodilution on Coagulation and Recombinant Factor VIIa Efficacy in Human Blood In Vitro Daniel N. Darlington, PhD, Angel

  20. Different Recovery Profiles of Coagulation Factors, Thrombin Generation, and Coagulation Function After Hemorrhagic Shock in Pigs

    DTIC Science & Technology

    2012-06-06

    Different recovery profiles of coagulation factors, thrombin generation, and coagulation function after hemorrhagic shock in pigs Wenjun Z. Martini ...Defense. Address for reprints: Wenjun Z. Martini , PhD, The US Army Institute of Surgical Research, 3698 Chambers Pass, Ft. Sam Houston, San Antonio, TX...control number 1. REPORT DATE 01 SEP 2015 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Different recovery profiles of

  1. Comparative thermometric coagulation studies of plasmas from normal outbred Swiss Webster mice and persons.

    PubMed

    Tsang, V C; Wyatt, C R; Damian, R T

    1979-06-01

    The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.

  2. Charging and coagulation of radioactive and nonradioactive particles in the atmosphere

    DOE PAGES

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios; ...

    2016-01-01

    Charging and coagulation influence one another and impact the particle charge and size distributions in the atmosphere. However, few investigations to date have focused on the coagulation kinetics of atmospheric particles accumulating charge. This study presents three approaches to include mutual effects of charging and coagulation on the microphysical evolution of atmospheric particles such as radioactive particles. The first approach employs ion balance, charge balance, and a bivariate population balance model (PBM) to comprehensively calculate both charge accumulation and coagulation rates of particles. The second approach involves a much simpler description of charging, and uses a monovariate PBM and subsequentmore » effects of charge on particle coagulation. The third approach is further simplified assuming that particles instantaneously reach their steady-state charge distributions. It is found that compared to the other two approaches, the first approach can accurately predict time-dependent changes in the size and charge distributions of particles over a wide size range covering from the free molecule to continuum regimes. The other two approaches can reliably predict both charge accumulation and coagulation rates for particles larger than about 0.04 micrometers and atmospherically relevant conditions. These approaches are applied to investigate coagulation kinetics of particles accumulating charge in a radioactive neutralizer, the urban atmosphere, and an atmospheric system containing radioactive particles. Limitations of the approaches are discussed.« less

  3. Removal of algal blooms from freshwater by the coagulation-magnetic separation method.

    PubMed

    Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck

    2013-01-01

    This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.

  4. Use of combined coagulation-adsorption process as pretreatment of landfill leachate

    PubMed Central

    2013-01-01

    Landfill leachate is an important pollution factor resulting from municipal landfill sites. Physical and chemical processes are the better option for pretreatment or full treatment of landfill leachate. This article presents a combination of pre-treatment method (coagulation and adsorption) for leachate collected from municipal solid waste open dumping site. Physico chemical characteristics of stabilized and fresh leachate were examined. Coagulation process was examined by using alum and ferric chloride. A low cost adsorbent, fly ash was used for adsorption studies. Coagulation studies were carried out for fresh and stabilized leachate. Adsorption studies have been conducted for alum pre-treated stabilized leachate. Effect of coagulant dose, adsorbent dose, pH and contact time were carried out. The effective optimum coagulant dosages were 0.6 g/L and 0.7 g/L for alum and ferric chloride respectively for stabilized leachate and incase of fresh leachate 0.8 g/L and 0.6 g/L for alum and ferric chloride respectively. For the alum pretreated stabilized leachate, the maximum COD removal is 28% using fly ash adsorbent with equilibrium time of 210 min and optimum dose of 6 g/L. Overall COD removal efficiency of 82% was obtained by coagulation using alum and adsorption using fly ash for stabilized leachate. The results obtained showed that combined coagulation and adsorption process can be used effectively for stabilized leachate treatment. PMID:23517661

  5. Efficacy of hemostasis for epidural venous plexus and safety for neural structure using soft coagulation system in spinal surgery: a laboratory investigation using a porcine model.

    PubMed

    Nishida, Kotaro; Kakutani, Kenichiro; Maeno, Koichiro; Takada, Toru; Yurube, Takashi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2013-10-01

    A laboratory investigation using porcine model. To clarify the effectiveness of the soft coagulation system for stopping bleeding from the epidural vein using different outputs and the safety in terms of tissue damage including spinal cord injury. Problems associated with coagulation using an electrosurgical device, such as carbonization of tissue or adhesion to the electrode, have been highlighted. So called "soft coagulation" has been developed to solve these problems. Its' utility as well as the safety of the neural structure in spine surgery has never been reported. A total of 3 animals and 45 spinal segments were used. Total laminectomy was performed to expose the dural tube and epidural venous plexus. Stable bleeding was induced by a 22 G needle puncture. Soft coagulation monopolar output (SCM), soft coagulation bipolar output (SCB), and conventional bipolar output (CB) were used as the coagulators. Valid hemostasis was defined as macroscopically complete bleeding stoppage by coagulation within 3 minutes. The neurological assessment was evaluated by somatosensory evoked potential. Histologic analysis was performed to determine the area of thermal damage. Valid hemostasis ratio was 75.0% of SCM group, 68.8% of SCB group, and 30.8% of CB group. Somatosensory evoked potential monitoring revealed that spinal cord injury was observed in 4 lesions (25%) of the SCM group. Neither bipolar groups (SCB and CB) showed any changes in waveform pattern. Histologic analysis revealed that severe thermal damages were observed in the epidural space of the SCM group. The usefulness of soft coagulation is revealed in terms of bleeding stoppage from epidural vessels and reduced soft-tissue damage compared with the conventional electric device. However, assessing the potential risk of severe neural tissue damage including spinal cord injury, a bipolar soft coagulation is strongly recommended for use in spine surgery.

  6. Role of tissue factor and protease-activated receptors in a mouse model of endotoxemia.

    PubMed

    Pawlinski, Rafal; Pedersen, Brian; Schabbauer, Gernot; Tencati, Michael; Holscher, Todd; Boisvert, William; Andrade-Gordon, Patricia; Frank, Rolf Dario; Mackman, Nigel

    2004-02-15

    Sepsis is associated with a systemic activation of coagulation and an excessive inflammatory response. Anticoagulants have been shown to inhibit both coagulation and inflammation in sepsis. In this study, we used both genetic and pharmacologic approaches to analyze the role of tissue factor and protease-activated receptors in coagulation and inflammation in a mouse endotoxemia model. We used mice expressing low levels of the procoagulant molecule, tissue factor (TF), to analyze the effects of TF deficiency either in all tissues or selectively in hematopoietic cells. Low TF mice had reduced coagulation, inflammation, and mortality compared with control mice. Similarly, a deficiency of TF expression by hematopoietic cells reduced lipopolysaccharide (LPS)-induced coagulation, inflammation, and mortality. Inhibition of the down-stream coagulation protease, thrombin, reduced fibrin deposition and prolonged survival without affecting inflammation. Deficiency of either protease activated receptor-1 (PAR-1) or protease activated receptor-2 (PAR-2) alone did not affect inflammation or survival. However, a combination of thrombin inhibition and PAR-2 deficiency reduced inflammation and mortality. These data demonstrate that hematopoietic cells are the major pathologic site of TF expression during endotoxemia and suggest that multiple protease-activated receptors mediate crosstalk between coagulation and inflammation.

  7. Causes and consequences of coagulation activation in sepsis: an evolutionary medicine perspective.

    PubMed

    Fiusa, Maiara Marx Luz; Carvalho-Filho, Marco Antonio; Annichino-Bizzacchi, Joyce M; De Paula, Erich V

    2015-05-06

    Coagulation and innate immunity have been linked together for at least 450 million years of evolution. Sepsis, one of the world's leading causes of death, is probably the condition in which this evolutionary link is more evident. However, the biological and the clinical relevance of this association have only recently gained the attention of the scientific community. During sepsis, the host response to a pathogen is invariably associated with coagulation activation. For several years, coagulation activation has been solely regarded as a mechanism of tissue damage, a concept that led to several clinical trials of anticoagulant agents for sepsis. More recently, this paradigm has been challenged by the failure of these clinical trials, and by a growing bulk of evidence supporting the concept that coagulation activation is beneficial for pathogen clearance. In this article we discuss recent basic and clinical data that point to a more balanced view of the detrimental and beneficial consequences of coagulation activation in sepsis. Reappraisal of the association between coagulation and immune activation from an evolutionary medicine perspective offers a unique opportunity to gain new insights about the pathogenesis of sepsis, paving the way to more successful approaches in both basic and clinical research in this field.

  8. A Pontential Agriculture Waste Material as Coagulant Aid: Cassava Peel

    NASA Astrophysics Data System (ADS)

    Othman, N.; Abd-Rahim, N.-S.; Tuan-Besar, S.-N.-F.; Mohd-Asharuddin, S.; Kumar, V.

    2018-02-01

    All A large amount of cassava peel waste is generated annually by small and medium scale industries. This has led to a new policy of complete utilization of raw materials so that there will be little or no residue left that could pose pollution problems. Conversion of these by-products into a material that poses an ability to remove toxic pollutant would increase the market value and ultimately benefits the producers. This study investigated the characteristics of cassava peel as a coagulant aid material and optimization process using the cassava peel was explored through coagulation and flocculation. This research had highlighted that the Cassava peels contain sugars in the form of polysaccharides such as starch and holocellulose. The FTIR results revealed that amino acids containing abundant of carboxyl, hydroxyl and amino groups which has significant capabilities in removing pollutants. Whereas analysis by XRF spectrometry indicated that the CP samples contain Fe2O3 and Al2O3 which might contribute to its coagulation ability. The optimum condition allowed Cassava peel and alum removed high turbidity up to 90. This natural coagulant from cassava peel is found to be an alternative coagulant aid to reduce the usage of chemical coagulants

  9. Effects of storage conditions of Moringa oleifera seeds on its performance in coagulation.

    PubMed

    Katayon, S; Noor, M J Megat Mohd; Asma, M; Ghani, L A Abdul; Thamer, A M; Azni, I; Ahmad, J; Khor, B C; Suleyman, A M

    2006-09-01

    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.

  10. Toward understanding the efficacy and mechanism of Opuntia spp. as a natural coagulant for potential application in water treatment.

    PubMed

    Miller, Sarah M; Fugate, Ezekiel J; Craver, Vinka Oyanedel; Smith, James A; Zimmerman, Julie B

    2008-06-15

    Historically, there is evidence to suggest that communities in the developing world have used plant-based materials as one strategy for purifying drinking water. In this study, the coagulant properties of Opuntia spp., a species of cactus, are quantitatively evaluated for the first time. Opuntia spp. was evaluated for turbidity removal from synthetic water samples, and steps were made toward elucidating the underlying coagulation mechanism. In model turbid water using kaolin clay particles at pH 10, Opuntia spp. reduced turbidity by 98% for a range of initial turbidities. This is similar to the observed coagulation activities previously described for Moringa oleifera, a widely studied natural coagulant. Although it has been reported that Moringa oleifera predominantly operates through charge neutralization, comparison of zeta potential measurements and transmission electron microscopy images of flocs formed by Opuntia spp. suggest that these natural coagulants operate through different mechanisms. It is suggested that Opuntia spp. operates predominantly through a bridging coagulation mechanism. Once optimized, application of these readily available plants as a part of point-of-use water treatment technology may offer a practical, inexpensive, and appropriate solution for producing potable water in some developing communities.

  11. Effects of low temperature on coagulation of kaolinite suspensions.

    PubMed

    Xiao, Feng; Ma, Jun; Yi, Peng; Huang, Ju-Chang Howard

    2008-06-01

    In this study, coagulation of kaolinite suspensions at low temperatures is compared with that at an ambient temperature of 22 degrees C, and the process is examined with regard to the coagulation rate (CR) and chemical aspects of coagulation. Experiments using a photometric dispersion analyzer (PDA) show that coagulation of kaolinite suspensions can be taken as a two-phase process. Low temperature greatly reduces the CR of the first phase but not that of the second one. On the other hand, results show that low temperature did not serve to impede the hydrolysis of aluminum [Al(III)] within 1 min of alum addition. The measurements of electrophoretic mobility (EM) indicate that destabilization of kaolinite particles by hydrolyzed Al species was not hindered by low temperature within 1 min of alum addition. Slow coagulation at low temperature is due to the lowered CR but not the altered chemistry aspect of Al(III). Furthermore, the change in settled turbidity after 20-min flocculation as a function of coagulant dosage was more severe in the cold because of the low CR. Elongating floc-growth time, as observed, was able to counterbalance the retarded CR at low temperature and improve turbidity removal efficiency.

  12. Characteristics of BPA removal from water by PACl-Al13 in coagulation process.

    PubMed

    Xiaoying, Ma; Guangming, Zeng; Chang, Zhang; Zisong, Wang; Jian, Yu; Jianbing, Li; Guohe, Huang; Hongliang, Liu

    2009-09-15

    This paper discussed the coagulation characteristics of BPA with polyaluminum chloride (PACl-Al(13)) as coagulant, examined the impact of coagulation pH, PACl-Al(13) dosage, TOC (total organic carbon) and turbidity on BPA removal, and analyzed the possible dominant mechanisms in water coagulation process. Formation and performance of flocs during coagulation processes were monitored using photometric dispersion analyzer (PDA). When the concentration of humic acid matters and turbidity was low in the solution, the experimental results showed that the removal of BPA experienced increase and subsequently decrease with the PACl-Al(13) dosage increasing. The optimal PACl-Al(13) dosage was found at BPA/PACl-Al(13)=1:2.6(M/M) under our experiment conditions. Results show that the maximum BPA removal efficiency occurred at pH 9.0 due to the adsorption by Al(13) aggregates onto BPA rather than charge neutralization mechanism by polynuclear aluminous salts in the solution. The humic acid matters and kaolin in the solution have significant effect on BPA removal with PACl-Al(13) in the coagulation. The BPA removal will be weakened at high humic matters. The removal rate of BPA increased and subsequently decreased with the turbidity increasing.

  13. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry.

    PubMed

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Lee, Seungmin; Murata, Aya; Omori, Shinji; Uchiyama, Hidetoshi; Inoue, Yoshinori; Kudo, Toshifumi; Toyofuku, Takahiro; Nagasawa, Masayuki; Uchimura, Isao; Nakamura, Tomomasa; Muneta, Takeshi

    2017-01-01

    In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability.

  14. Effect of circulating tissue factor on hypercoagulability in type 2 diabetes mellitus studied by rheometry and dielectric blood coagulometry.

    PubMed

    Uchimura, Isao; Kaibara, Makoto; Nagasawa, Masayuki; Hayashi, Yoshihito

    2016-01-01

    Hypercoagulability in type 2 diabetes mellitus (T2DM) patients increases their risk of cardiovascular diseases. The aim of this work was to investigate the hypercoagulation mechanism in T2DM patients in terms of circulating tissue factor (TF). Whole blood coagulation tests by damped oscillation rheometry and dielectric blood coagulometry (DBCM) were performed. The average coagulation time was significantly shorter for T2DM patients than for healthy controls. In vitro addition of either anti-TF or anti-activated factor VII (FVIIa) antibody to hypercoagulable blood samples prolonged coagulation times for one group of patients, while coagulation times remained short for another group. The levels of circulating TF were estimated in the former group by measuring the coagulation times for blood samples from healthy subjects with addition of various concentrations of TF and comparing them with the coagulation times for the group. The results indicated that the levels of circulating TF were on the order of subpicomolar at most. Circulating TF is at least partially responsible for a hypercoagulable group of T2DM patients, while an abnormality in the intrinsic coagulation pathway probably occurs in the other group.

  15. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry

    PubMed Central

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Lee, Seungmin; Murata, Aya; Omori, Shinji; Uchiyama, Hidetoshi; Inoue, Yoshinori; Kudo, Toshifumi; Toyofuku, Takahiro; Nagasawa, Masayuki; Uchimura, Isao; Nakamura, Tomomasa; Muneta, Takeshi

    2017-01-01

    Background: In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. Objective: The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Methods: Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Results: Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Conclusions: Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability. PMID:28800301

  16. Sizes of particles formed during municipal wastewater treatment.

    PubMed

    Lech, Smoczynski; Marta, Kosobucka; Michal, Smoczynski; Harsha, Ratnaweera; Krystyna, Pieczulis-Smoczynska

    2017-02-01

    Volumetric diameters Dv and specific surface area SpS of sludge particles formed during chemical coagulation and electrocoagulation of sewage were determined. The obtained aggregate-flocs differed substantially in both Dv and SpS values. The differences in Dv and SpS values of the analyzed particles were interpreted based on theoretical models for expanding aggregates. The most uniform particles were formed under exposure to: (a) optimal and maximal doses of PIX, (b) optimal doses of PAX, (c) maximal doses of the Al electro-coagulant. The lowest PIX dose produced the least uniform particles. Sludge aggregates-particles produced under exposure to minimal doses of PIX and the Al electro-coagulant were characterized by the lowest SpS values. Sludge particles coagulated by PAX and the particles formed at higher doses of PIX and the Al electro-coagulant had higher SpS values. The particles formed at all doses of the applied coagulants and electro-coagulants were generally classified into two size ranges: the main range and the secondary range. Most particles belonged to the main size range. An increase in the percentage of colloidal hydroxide particles in sewage sludge increased SpS.

  17. Integration of coagulation and adsorption for removal of N-nitrosodimethylamine (NDMA) precursors from biologically treated municipal wastewater.

    PubMed

    Wang, Miaomiao; Meng, Yingjie; Ma, Defang; Wang, Yan; Li, Fengli; Xu, Xing; Xia, Chufan; Gao, Baoyu

    2017-05-01

    This study investigated the N-nitrosodimethylamine (NDMA) formation potential of various dissolved organic matter (DOM) fractions in biologically treated municipal wastewater by UF fractionation, XAD-8 resin adsorption isolation, and excitation and emission matrix (EEM) fluorescence spectroscopy. Removal of various NDMA precursor fractions was also analyzed to evaluate the efficiency of traditional water treatment processes (coagulation, adsorption, and coagulation-adsorption). Results showed that NDMA were mainly formed by low molecular weight (MW) fractions (<30 kDa) and hydrophilic fractions (HiS) in biologically treated municipal wastewater. Integrated coagulation-adsorption treatments showed the highest reduction capacity for NDMA formation potential (57%), followed by isolated adsorption treatment (50%) and isolated coagulation treatment (28%). The powdered activated carbon (PAC) adsorption process could reduce the high MW precursors (>30 kDa) by 48%, which was higher than other treatments. In contrast, the highest uptake (66%) of low MW precursors (<30 kDa) was achieved by the coagulation-adsorption process. All treatments preferentially removed the hydrophobic acids (HoA) fraction compared to other fractions. Coagulation could remove more fulvic acid-like substances and adsorption could remove more microbial by-products and aromatic proteins.

  18. [Influencing factors and mechanism of arsenic removal during the aluminum coagulation process].

    PubMed

    Chen, Gui-Xia; Hu, Cheng-Zhi; Zhu, Ling-Feng; Tong, Hua-Qing

    2013-04-01

    Aluminum coagulants are widely used in arsenic (As) removal during the drinking water treatment process. Aluminium chloride (AlCl3) and polyaluminium chloride (PACl) which contains high content of Al13 were used as coagulants. The effects of aluminum species, pH, humic acid (HA) and coexisting anions on arsenic removal were investigated. Results showed that AlCl3 and PACl were almost ineffective in As(II) removal while the As(V) removal efficiency reached almost 100%. pH was an important influencing factor on the arsenic removal efficiency, because pH influenced the distribution of aluminum species during the coagulation process. The efficiency of arsenic removal by aluminum coagulants was positively correlated with the content of Al13 species. HA and some coexisting anions showed negative impact on arsenic removal because of the competitive adsorption. The negative influence of HA was more pronounced at low coagulant dosages. PO4(3-) and F(-) showed marked influence during arsenic removal, but there was no obvious influence when SiO3(2-), CO3(2-) and SO4(2-) coexisted. The present study would be helpful to direct arsenic removal by enhanced coagulation during the drinking water treatment.

  19. A novel suction/coagulation integrated probe for achieving better hemostasis: development and clinical use.

    PubMed

    Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu

    2018-06-01

    Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.

  20. Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.

    PubMed

    Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao

    2006-01-01

    The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.

  1. An in vitro analysis of the effect of acidosis on coagulation in chronic disease states - a thromboelastograph study.

    PubMed

    White, Hayden; Bird, Robert; Sosnowski, Kellie; Jones, Mark

    2016-06-01

    Thrombosis is a complication of many chronic illnesses. Chronic obstructive pulmonary disease (COPD) and diabetes mellitus are common medical conditions frequently associated with a hypercoagulable state. Acidaemia has been shown to reduce coagulation. COPD and diabetes mellitus during acute deterioration can present with a severe acidaemia. The impact of this acidaemia on coagulation is poorly studied. Patients presenting with a diagnosis of diabetic ketoacidosis or type II respiratory failure from COPD and a pH of less than 7.2 were included in our study. A coagulation screen and a thromboelastograph (TEG) were performed on admission and 24 hours later. The mean pH on admission was 7.07 and mean base excess was -16.3. The activated partial thromboplastin time was associated with pH change but remained within the normal range (26-41 s). All other coagulation and TEG parameters failed to show evidence of association (p>0.05). In the two models of non-haemorrhagic acidosis investigated, coagulation was not altered by the changes in pH. More work is needed to understand the complex relationship between factors affecting coagulation in individual disease processes. © 2016 Royal College of Physicians.

  2. Method of removing arsenic and other anionic contaminants from contaminated water using enhanced coagulation

    DOEpatents

    Teter, David M.; Brady, Patrick V.; Krumhansl, James L.; Khandaker, Nadim R.

    2006-11-21

    An improved water decontamination process comprising contacting water containing anionic contaminants with an enhanced coagulant to form an enhanced floc, which more efficiently binds anionic species (e.g., arsenate, arsenite, chromate, fluoride, selenate, and borate, and combinations thereof) predominantly through the formation of surface complexes. The enhanced coagulant comprises a trivalent metal cation coagulant (e.g., ferric chloride or aluminum sulfate) mixed with a divalent metal cation modifier (e.g., copper sulfate or zinc sulfate).

  3. Implementation of a microcontroller-based semi-automatic coagulator.

    PubMed

    Chan, K; Kirumira, A; Elkateeb, A

    2001-01-01

    The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.

  4. Coagulation behavior of humic acid in aqueous solutions containing Cs+, Sr2+ and Eu3+: DLS, EEM and MD simulations.

    PubMed

    Tan, Liqiang; Tan, Xiaoli; Mei, Huiyang; Ai, Yuejie; Sun, Lu; Zhao, Guixia; Hayat, Tasawar; Alsaedi, Ahmed; Chen, Changlun; Wang, Xiangke

    2018-05-01

    The coagulation behaviors of humic acid (HA) with Cs + (10-500 mM), Sr 2+ (0.8-10.0 mM) and Eu 3+ (0.01-1.0 mM) at different pH values (2.8, 7.1 and 10.0) were acquired through a dynamic light scattering (DLS) technique combined with spectroscopic analysis and molecular dynamic (MD) simulations. The coagulation rate and the average hydrodynamic diameter () increased significantly as the concentration of nuclides increased. could be scaled to time t as ∝ t a at higher Sr 2+ concentrations, which shows that HA coagulation is consistent with the diffusion-limited colloid aggregation (DLCA) model. Trivalent Eu 3+ induced HA coagulation at a much lower concentration than bivalent Sr 2+ and monovalent Cs + . The coagulation value ratio of Sr 2+ and Eu 3+ to Cs + is almost proportional to Z -6 , indicating that the HA coagulation process is generally consistent with the Schulze-Hardy rule. Spectroscopic analysis indicated that the complexation between nuclides and carboxylic/phenolic groups of HA molecules played important roles in the coagulation of HA. MD modelling suggested that Sr 2+ and Eu 3+ ions increased the coagulation process through the formation of intra- or inter-molecular bridges between negatively charged HA molecules, whereas for Cs + , no inter-molecular bridges were formed. This work offers new insight into the interactions between HA and radionuclides and provides a prediction for the roles of HA in the transportation and elimination of radionuclides in severely polluted environments. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Physical and oxidative removal of organics during Fenton treatment of mature municipal landfill leachate.

    PubMed

    Deng, Yang

    2007-07-19

    Municipal landfill leachate, especially mature leachate, may disrupt the performance of moderately-sized municipal activated sludge wastewater treatment plants, and likewise tend to be recalcitrant to biological pretreatment. Recently, Fenton methods have been investigated for chemical treatment or pre-treatment of mature leachate. In this paper, the results of laboratory tests to determine the roles of oxidation and coagulation in reducing the organic content of mature leachate during Fenton treatment are presented. The efficiencies of chemical oxygen demand (COD) oxidation and coagulation were tested, and the ratio of COD removal by oxidation to that by coagulation was assessed, under various operating conditions. Low initial pH, appropriate relative and absolute Fenton reagent dosages, aeration, and stepwise addition of reagents increased COD removal by oxidation and the importance of oxidation relative to coagulation. Simultaneous aeration and stepwise reagent addition allowed comparable treatment without initial acidification pH, due to the generation of acidic organic intermediates and the continuous input of CO2. On the other hand, high COD oxidation efficiency and low ferrous dosage inhibited COD removal by coagulation. At significantly high oxidation efficiency, overall COD reduction decrease slightly due to low coagulation efficiency. Under the most favorable conditions (initial pH 3, molar ratio [H(2)O(2)]/[Fe2+]=3, [H2O2]=240 mM, and six dosing steps), 61% of the initial COD was removed, and the ratio of COD removal oxidation to coagulation was 0.75. Results highlighted the synergistic roles of oxidation and coagulation in Fenton treatment of mature leachate, and the role of oxidation in controlling the efficiency of removal of COD by coagulation.

  6. Probe measurements and numerical model predictions of evolving size distributions in premixed flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Filippo, A.; Sgro, L.A.; Lanzuolo, G.

    2009-09-15

    Particle size distributions (PSDs), measured with a dilution probe and a Differential Mobility Analyzer (DMA), and numerical predictions of these PSDs, based on a model that includes only coagulation or alternatively inception and coagulation, are compared to investigate particle growth processes and possible sampling artifacts in the post-flame region of a C/O = 0.65 premixed laminar ethylene-air flame. Inputs to the numerical model are the PSD measured early in the flame (the initial condition for the aerosol population) and the temperature profile measured along the flame's axial centerline. The measured PSDs are initially unimodal, with a modal mobility diameter ofmore » 2.2 nm, and become bimodal later in the post-flame region. The smaller mode is best predicted with a size-dependent coagulation model, which allows some fraction of the smallest particles to escape collisions without resulting in coalescence or coagulation through the size-dependent coagulation efficiency ({gamma}{sub SD}). Instead, when {gamma} = 1 and the coagulation rate is equal to the collision rate for all particles regardless of their size, the coagulation model significantly under predicts the number concentration of both modes and over predicts the size of the largest particles in the distribution compared to the measured size distributions at various heights above the burner. The coagulation ({gamma}{sub SD}) model alone is unable to reproduce well the larger particle mode (mode II). Combining persistent nucleation with size-dependent coagulation brings the predicted PSDs to within experimental error of the measurements, which seems to suggest that surface growth processes are relatively insignificant in these flames. Shifting measured PSDs a few mm closer to the burner surface, generally adopted to correct for probe perturbations, does not produce a better matching between the experimental and the numerical results. (author)« less

  7. Influence of micellar calcium and phosphorus on rennet coagulation properties of cows milk.

    PubMed

    Malacarne, Massimo; Franceschi, Piero; Formaggioni, Paolo; Sandri, Sandro; Mariani, Primo; Summer, Andrea

    2014-05-01

    The main requirement for milk processed in most cheese typologies is its rennet coagulation ability. Despite the increasing number of studies, the causes for abnormal coagulation of milk are not fully understood. The aim of this study was to ascertain relationships between milk characteristics and its rennet coagulation ability, focusing on the influence of calcium (Ca) and phosphorus (P). Ca and P are essential constituents of the micelles. Micellar P can be present as part of colloidal calcium phosphate (inorganic-P) or covalently bound to caseins as phosphate groups (casein-P). Eighty one herd milk samples (SCC<400 000 cell/ml) were classified as Optimal (8), Suboptimal (39) Poor (29) and Non-coagulating milk (5), according to their rennet coagulation parameters as assessed by lactodynamographic test. Samples were analysed for their chemical composition (basic composition, protein fractions, minerals and salt equilibria), physicochemical parameters (pH and titratable acidity) and rheological properties. Optimal milk was characterised by the highest contents of major constituents, protein fractions and minerals, lowest content of chloride and highest values of titratable acidity. Non-coagulating milk was characterised by the highest values of pH and the lowest of titratable acidity. At micellar level, Optimal milk showed the highest values of colloidal Ca, casein-P and colloidal Mg (g/100 g casein), while Non-coagulating milk showed the lowest values. Interestingly, there was no statistical difference regarding the content of colloidal inorganic-P (g/100 g casein) between Optimal and Non-coagulating milks. Overall, high mineralisation of the micelle (expressed as g inorganic-P/100 g casein) positively affect its rennetability. However, excessive mineralisation could lead to a reduction of the phosphate groups (g casein-P/100 g casein) available for curd formation.

  8. Improvement of the coagulation/flocculation process using a combination of Moringa oleifera lam with anionic polymer in water treatment.

    PubMed

    Bongiovani, Milene Carvalho; Camacho, Franciele Pereira; Nishi, Letícia; Coldebella, Priscila Ferri; Valverde, Karina Cardoso; Vieira, Angélica Marquetotti Salcedo; Bergamasco, Rosângela

    2014-01-01

    The objective of this study is to investigate the impacts of anionic polymer as a flocculant aid on the coagulation/flocculation performance with a saline solution of Moringa oleifera as a coagulant to provide larger flocs and decrease the time sedimentation. For the tests, raw water was used from Pirapó River Basin (Maringá, Paraná, Brazil). Optimization of coagulation/flocculation tests was initially performed in a jar-test with a dosage of M. oleifera Lam (crude extract--MO, oil-extracted with ethanol--MO (et) and hexane--MO (hex) 1% m/v) as the coagulant that ranged from 10 to 60 mg L(-1) and of the anionic polymer 0.1% as a flocculant aid with a dosage that ranged from 0 to 0.4 mg L(-1). The parameters analysed were colour, turbidity and compounds with absorption in UV254nm. In view of the statistical analysis results, MO (hex) with a dosage of 30 mg L(-1) was chosen as a coagulant for the next tests of coagulation/flocculation. When anionic polymer was used alone (0.0 mg L(-1) of MO (hex)), parameters were not removed and there was no generation of heavy flocs as compared with the combination of MO (hex) with the anionic polymer. Statistical analysis showed that MO (hex) obtained the highest removals of the parameters analysed in lower dosages and no significant increase in parameters removal was observed when the polymer dosage was increased. The efficacy of the coagulant +/- anionic polymer was optimal when 30mg L(-1) of MO (hex) was used as a coagulant and 0.1 mg L(-1) of the anionic polymer was used as a flocculant aid, decreasing the time sedimentation from 1 h to 15 min.

  9. Proposal of the Coagulation Score as a Predictor for Short-Term and Long-Term Outcomes of Patients with Resectable Gastric Cancer.

    PubMed

    Kanda, Mitsuro; Tanaka, Chie; Kobayashi, Daisuke; Mizuno, Akira; Tanaka, Yuri; Takami, Hideki; Iwata, Naoki; Hayashi, Masamichi; Niwa, Yukiko; Yamada, Suguru; Fujii, Tsutomu; Sugimoto, Hiroyuki; Murotani, Kenta; Fujiwara, Michitaka; Kodera, Yasuhiro

    2017-02-01

    Systemic hemostasis and thrombosis activation has been implicated in tumor progression and metastasis. This study aimed to investigate the use of coagulation factors as a novel prediction method for postoperative outcomes after curative gastrectomy in patients with stage II/III gastric cancer (GC). Overall, 126 patients with stage II/III GC who underwent gastrectomy between May 2003 and February 2016 were eligible for inclusion in the study. We retrospectively evaluated the predictive value of preoperative platelet count and plasma fibrinogen and d-dimer levels, and coagulation score (0: fibrinogen and d-dimer both below upper limits; 1: either fibrinogen or d-dimer over upper limits; 2: both fibrinogen and d-dimer over upper limits) for short- and long-term outcomes. Postoperative complications were significantly more frequent in patients with elevated preoperative d-dimer levels compared with those with normal d-dimer levels (26 vs. 10 %; p = 0.032). The prevalence of postoperative complications showed a stepwise increase in proportion to the coagulation score. Patients with a coagulation score of 2 had significantly larger tumors (p = 0.013) and significantly greater intraoperative blood loss (p = 0.004) than those who scored 0 or 1. Coagulation score showed the highest values distinguished high-risk patients in overall and disease-free survival, and a coagulation score of 2 was an independent prognostic factor for recurrence. Patients with a coagulation score of 2 experienced a significantly higher prevalence of liver metastasis as an initial recurrence than those who scored 0 or 1 (p = 0.019). The coagulation score is a simple and promising predictor for postoperative complications and recurrence after gastrectomy in stage II/III GC patients.

  10. MR Coagulation: A Novel Minimally Invasive Approach to Aneurysm Repair.

    PubMed

    Cohen, Ouri; Zhao, Ming; Nevo, Erez; Ackerman, Jerome L

    2017-11-01

    To demonstrate a proof of concept of magnetic resonance (MR) coagulation, in which MR imaging scanner-induced radiofrequency (RF) heating at the end of an intracatheter long wire heats and coagulates a protein solution to effect a vascular repair by embolization. MR coagulation was simulated by finite-element modeling of electromagnetic fields and specific absorption rate (SAR) in a phantom. A glass phantom consisting of a spherical cavity joined to the side of a tube was incorporated into a flow system to simulate an aneurysm and flowing blood with velocities of 0-1.7 mL/s. A double-lumen catheter containing the wire and fiberoptic temperature sensor in 1 lumen was passed through the flow system into the aneurysm, and 9 cm 3 of protein solution was injected into the aneurysm through the second lumen. The distal end of the wire was laid on the patient table as an antenna to couple RF from the body coil or was connected to a separate tuned RF pickup coil. A high RF duty-cycle turbo spin-echo pulse sequence excited the wire such that RF energy deposited at the tip of the wire coagulated the protein solution, embolizing the aneurysm. The protein coagulation temperature of 60°C was reached in the aneurysm in ∼12 seconds, yielding a coagulated mass that largely filled the aneurysm. The heating rate was controlled by adjusting pulse-sequence parameters. MR coagulation has the potential to embolize vascular defects by coagulating a protein solution delivered by catheter using MR imaging scanner-induced RF heating of an intracatheter wire. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  11. Surgical energy device using steam jet for robotic assisted surgery.

    PubMed

    Yoshiki, Hitoshi; Tadano, Kotaro; Ban, Daisuke; Ohuchi, Katsuhiro; Tanabe, Minoru; Kawashima, Kenji

    2015-01-01

    In robotic assisted surgery, the carbonization and the adherence of coagulated tissues caused by surgical energy devices are problems. We propose a surgical energy device using a steam jet to solve the problems. The device applies a steam jet and performs coagulation and hemostasis. The exposed tissue is heated quickly with latent heat of the steam. The carbonization and the adherence of the tissue can be avoided. We prototyped a steam jet coagulator to prove the concept. The coagulator was mounted on the laparoscopic surgical robot. The effectiveness of the coagulation and hemostasis using steam was confirmed by the in vitro experiment on the chicken's liver and the in vivo experiments on the pig's spleen under the robotic assisted laparoscopic environment.

  12. Metals in airpollution particles decrease whole blood coagulation time

    EPA Science Inventory

    The mechanism underlying the pro-coagulative effect of air pollution particle exposure is not known. We tested the postulate that 1) the soluble fraction ofan air pollution particle can affect whole blood coagulation time and 2) metals included in the soluble fraction are respons...

  13. Comparison of the level of residual coagulant activity in different cheese varieties.

    PubMed

    Bansal, Nidhi; Fox, Patrick F; McSweeney, Paul L H

    2009-08-01

    The coagulant retained in cheese curd is a major contributor to proteolysis during ripening. The objective of this study was to quantify residual coagulant in 9 cheese varieties by measuring its activity on a synthetic heptapeptide (Pro-Thr-Glu-Phe-[NO2-Phe]-Arg-Leu) assayed using reversed-phase HPLC. The level of residual coagulant activity was highest in Camembert cheese, probably due to its low pH at whey drainage and the high moisture content of the cheese, followed in order by Feta=Port du Salut=Cheddar>Gouda>Emmental=Parmigiano Reggiano=low-moisture part-skim Mozzarella=Mozzarella di Bufala Campana. The high cooking temperature (50-54 degrees C) used during the manufacture of Emmental and Parmigiano Reggiano cheeses and the cooking and stretching step in hot water during the manufacture of Mozzarella cheese may be the reasons for the lowest residual coagulant activity in these cheeses. The level of residual coagulant activity was higher in Feta cheese made from milk concentrated by ultrafiltration than in conventional Feta.

  14. Dataset on the cost estimation for spent filter backwash water (SFBW) treatment.

    PubMed

    Ebrahimi, Afshin; Mahdavi, Mokhtar; Pirsaheb, Meghdad; Alimohammadi, Fariborz; Mahvi, Amir Hossein

    2017-12-01

    The dataset presented in this article are related to the research article entitled "Hybrid coagulation-UF processes for spent filter backwash water treatment: a comparison studies for PAFCl and FeCl 3 as a pre-treatment" (Ebrahimi et al., 2017) [1]. This article reports the cost estimation for treating produced spent filter backwash water (SFBW) during water treatment in Isfahan- Iran by various methods including primary sedimentation, coagulation & flocculation, second clarification, ultra filtration (UF) and recirculation of settled SFBW to water treatment plant (WTP) entrance. Coagulation conducted by PAFCl and FeCl 3 as pre polymerized and traditional coagulants. Cost estimation showed that contrary to expectations, the recirculation of settled SFBW to WTP entrance is more expensive than other method and it costs about $ 37,814,817.6. Versus the cheapest option related to separate primary sedimentation, coagulation & flocculation in WTP. This option cost about $ 4,757,200 and $ 950,213 when FeCl3 and PAFCl used as coagulant, respectively.

  15. Effect of high pressures on the enzymatic activity of commercial milk protein coagulants

    NASA Astrophysics Data System (ADS)

    Wiśniewska, Krystyna; Reps, Arnold; Jankowska, Agnieszka

    2014-04-01

    This study was aimed at determining the effect of high pressures in the range of 100-1000 MPa/15 min, applied in 100 MPa increments, on the coagulating and proteolytic activity of commercial coagulants produced with genetic engineering methods: Maxiren, Chymogen, Chymax and of a natural rennin preparation, Hala. The coagulating activity of Hala preparation differed compared with the other preparations, due to greater resistance to high pressures, especially in the range of 500-600 MPa. The preparations produced with genetic engineering methods lost their capability for milk protein coagulation by 500 MPa. Pressurization at 200 MPa contributed to their reduced capability for casein macroproteolysis. In contrast, an increase in Chymax, Chymogen, Maxiren and Hala preparations' hydrolytic capability for the macroproteolysis of isoelectric casein was observed upon pressure treatment at 100 and 400 MPa and for microproteolysis after pressure treatment at 200 MPa. Storage (48 h/5°C) of the pressurized preparations had an insignificant effect on their coagulating and proteolytic activities.

  16. Studies on the treatment of surface water using rajma seeds

    NASA Astrophysics Data System (ADS)

    Merlin, S. Babitha; Abirami, M.; Kumar, R. Suresh

    2018-03-01

    Indiscriminate disposal of wastewater with suspended solids have led to higher amount of pollution to the natural water bodies. Turbidity removal becomes an essential part in the water treatment when surface water is used for drinking purpose, this can be achieved by means of coagulation process. Coagulation process is the dosing of a coagulant in water, resulting in the destabilization of negatively charged particles. Commercial coagulants which were widely used can synthesize by-products in turn may pollute the environment and deteriorate the ecosystem at a slow rate. So, now-a-days natural coagulants are used as a potential substitute because it's biodegradable, ecofriendly and non-toxic. In this study, the turbid surface water samples were treated using powdered seeds of Rajma (natural coagulant) followed by variations in dosage, settling time and pH were also studied. From the results obtained, it was found that the Rajma seeds powder achieved 48.80% efficiency for 0.5 g/l of optimum dose at pH 6 for 20 min settling time respectively.

  17. How Frequency of Electrosurgical Current and Electrode Size Affect the Depth of Electrocoagulation.

    PubMed

    Taheri, Arash; Mansoori, Parisa; Bahrami, Naeim; Alinia, Hossein; Watkins, Casey E; Feldman, Steven R

    2016-02-01

    Many factors affect the depth of electrocoagulation. To evaluate the effect of current frequency and electrode size on the depth of electrocoagulation. In this in vitro study, 4 cylindrical electrodes (2, 2.3, 3, and 4 mm) were used to apply 3 electrosurgical currents (0.4, 1.5, and 3 MHz) to bovine liver. Each electrode was placed at different points on the surface of the liver, and energy at various levels and frequencies was delivered to the tissue. Subsequently, cross-sections of the liver were analyzed. Coagulation started at the periphery of the electrode-tissue contact area. With higher energy levels, coagulation spreads to involve the remainder of the contact area. Neither the frequency nor the electrode size had any effect on this coagulation pattern. The frequency of the current also did not show any relation with depth of coagulation; however, there was a direct correlation between the size of the electrode and the depth of coagulation. Larger-tip electrodes provided deeper coagulation compared with finer-tip electrodes.

  18. Fate of nanoparticles during alum and ferric coagulation monitored using single particle ICP-MS.

    PubMed

    Donovan, Ariel R; Adams, Craig D; Ma, Yinfa; Stephan, Chady; Eichholz, Todd; Shi, Honglan

    2018-03-01

    In this study, aluminum sulfate, ferric sulfate, ferric chloride, and poly(diallyldimethylammonium chloride) (pDADMAC) coagulation removal of citrate-stabilized silver and gold nanoparticles (NPs) and uncoated titanium dioxide, cerium dioxide, and zinc oxide NPs was investigated using a single particle (SP) ICP-MS direct monitoring technique. Zone 2 (charge neutralization) coagulation was performed in river water and more commonly used Zone 4 (sweep floc) coagulation was performed in both river and lake water with environmentally relevant concentrations of selected NPs added. SP-ICP-MS was used to detect NP and dissolved species, characterize the size distribution, and quantify particle concentration as well as dissolved species before and after treatments. Other parameters including pH, dissolved organic carbon, turbidity, and UV 254 absorbance were monitored to characterize treatment efficiency. Charge neutralization (Zone 2) coagulation resulted in 48-85% removal of citrate-stabilized NPs and 90-99% removal of uncoated NPs from river water. Sweep floc (Zone 4) coagulation in river water resulted in 36-94% removal of citrate-stabilized NPs and 91-99% removal of uncoated NPs both with and without polymer addition. Zone 4 coagulation conditions in lake water resulted in 77-98% removal of citrate-stabilized NPs and 59-96% removal of uncoated NPs without polymer. These results indicate that NP removal depends on NP surface and stability, the nature of the source water, and the coagulant type and approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Anti-Coagulant and Anti-Thrombotic Properties of Blacklip Abalone (Haliotis rubra): In Vitro and Animal Studies.

    PubMed

    Suleria, Hafiz Ansar Rasul; Masci, Paul P; Zhao, Kong-Nan; Addepalli, Rama; Chen, Wei; Osborne, Simone A; Gobe, Glenda C

    2017-08-04

    Sulphated polysaccharides with anti-thrombotic and anti-coagulant activities have been found in various marine biota. In this study, a previously characterised anti-thrombotic and anti-coagulant extract from blacklip abalone was fractionated by anion exchange chromatography (AEC), pooled (on a sulphated polysaccharide basis) and administered to Wistar rats via oral gavage (N = 8) for assessment as an oral therapeutic. To ensure that the preparation had anti-coagulant activity prior to oral administration, it was assessed in rat blood by thromboelastography (TEG) significantly increasing reaction (R) time (or time until clot formation). Following in vitro confirmation of anti-coagulant activity, 40 mg of the preparation was orally administered to rats with blood samples collected at 2, 4, and 6 h post-gavage. Assessment of all blood samples by TEG showed some prolongation of R time from 355 to 380 s after 4 h. Dosing of the post-gavage blood samples with the abalone preparation to confirm anti-thrombotic activity in vitro revealed residual anti-coagulant activity, further suggesting that oral administration did increase anti-coagulant potential in the collected blood but that bioavailability was low. Assessment of tissues and haematological parameters showed no obvious harmful effects of the abalone preparation in animals. In summary, even though oral administration of fractionated and pooled blacklip abalone extract to rats delayed clotting after 4 h, bioavailability of the preparation appeared to be low and may be more appropriate for intravenous administration as an anti-thrombotic or anti-coagulant therapeutic.

  20. Chemical coagulation-based processes for trace organic contaminant removal: current state and future potential.

    PubMed

    Alexander, Jonathan T; Hai, Faisal I; Al-Aboud, Turki M

    2012-11-30

    Trace organic contaminants have become an increasing cause of concern for governments and water authorities as they attempt to respond to the potential challenges posed by climate change by implementing sustainable water cycle management practices. The augmentation of potable water supplies through indirect potable water reuse is one such method currently being employed. Given the uncertainty surrounding the potential human health impacts of prolonged ingestion of trace organic contaminants, it is vital that effective and sustainable treatment methods are utilized. The purpose of this article is to provide a comprehensive literature review of the performance of the chemical coagulation process in removing trace organic contaminants from water. This study evaluated the removal data collated from recent research relating to various trace organic contaminants during the coagulation process. It was observed that there is limited research data relating to the removal of trace organic contaminants using coagulation. The findings of this study suggest that there is a gap in the current research investigating the potential of new types of coagulants and exploring coagulation-based hybrid processes to remove trace organic contaminants from water. The data analysed in this study regarding removal efficiency suggests that, even for the significantly hydrophobic compounds, hydrophobicity is not the sole factor governing removal of trace organic contaminants by coagulation. This has important implications in that the usual practice of screening coagulants based on turbidity (suspended solid) removal proves inadequate in the case of trace organic contaminant removal. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Genotoxicity testing of cooked cured meat pigment (CCMP) and meat emulsion coagulates prepared with CCMP.

    PubMed

    Stevanović, M; Cadez, P; Zlender, B; Filipic, M

    2000-07-01

    The preformed cooked cured meat pigment (CCMP) synthesized directly from bovine red blood cells or through a hemin intermediate was found to be a viable colorant for application to comminuted pork as a nitrite substitute. However the genotoxicity of CCMP and meat emulsion coagulates prepared with CCMP has not been evaluated. Therefore the objectives of this work were to investigate genotoxicity of CCMP and the influence of CCMP addition on genotoxicity and the content of residual nitrite in model meat emulsion coagulates. Meat emulsions were prepared from white (musculus longissimus dorsi) and red (musculus quadriceps femoris) pork muscles with two different amounts of synthesized pigment CCMP. Comparatively, emulsions with fixed addition of nitrite salt and emulsions without any addition for color development were made. Genotoxicity of CCMP and meat emulsion coagulates was tested with the SOS/umu test and the Ames test. Neither CCMP nor meat emulsion coagulates prepared with CCMP or nitrite salt were genotoxic in the SOS/umu test. In the Ames test using Salmonella Typhimurium strains TA98 and TA100 samples of coagulates prepared with CCMP and with nitrite showed weak mutagenic activity in Salmonella Typhimurium strain TA100 but only in the absence of the metabolic activation, while CCMP was not mutagenic. Coagulates prepared with CCMP contained significantly less residual nitrite than coagulates prepared with nitrite salt. These results indicate that from the human health standpoint the substitution of nitrite salt with CCMP would be highly recommendable.

  2. Uniqueness of Mass-Conserving Self-similar Solutions to Smoluchowski's Coagulation Equation with Inverse Power Law Kernels

    NASA Astrophysics Data System (ADS)

    Laurençot, Philippe

    2018-03-01

    Uniqueness of mass-conserving self-similar solutions to Smoluchowski's coagulation equation is shown when the coagulation kernel K is given by K(x,x_*)=2(x x_*)^{-α } , (x,x_*)\\in (0,∞)^2 , for some α >0.

  3. 40 CFR 141.134 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... byproduct precursors and enhanced coagulation or enhanced softening. Systems must report the information... quarterly for TOC under the requirements of § 141.132(d) and required to meet the enhanced coagulation or... compliance with the enhanced coagulation or enhanced softening percent removal requirements in § 141.135(b...

  4. 40 CFR 141.134 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... byproduct precursors and enhanced coagulation or enhanced softening. Systems must report the information... quarterly for TOC under the requirements of § 141.132(d) and required to meet the enhanced coagulation or... compliance with the enhanced coagulation or enhanced softening percent removal requirements in § 141.135(b...

  5. 40 CFR 141.134 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... byproduct precursors and enhanced coagulation or enhanced softening. Systems must report the information... quarterly for TOC under the requirements of § 141.132(d) and required to meet the enhanced coagulation or... compliance with the enhanced coagulation or enhanced softening percent removal requirements in § 141.135(b...

  6. Coagulation pretreatment for ultrafiltration of deinking effluents containing flexographic inks

    Treesearch

    Bruno Chabot; Gopal A. Krishnagopalan; Said Abubakr

    1999-01-01

    This study was carried out to determine the potential of coagulation pretreatment with organic or inorganic coagulants to improve ultrafiltration performance during processing of wash deinking effluents containing flexographic inks. Wash filtrate effluents generated from mixtures of old flexographic and offset newspapers and old magazines were pretreated with a...

  7. Coagulation of dust grains in the plasma of an RF discharge in argon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankelevich, Yu. A.; Olevanov, M. A.; Pal', A. F.

    2009-03-15

    Results are presented from experimental studies of coagulation of dust grains of different sizes injected into a low-temperature plasma of an RF discharge in argon. A theoretical model describing the formation of dust clusters in a low-temperature plasma is developed and applied to interpret the results of experiments on the coagulation of dust grains having large negative charges. The grain size at which coagulation under the given plasma conditions is possible is estimated using the developed theory. The theoretical results are compared with the experimental data.

  8. Theories of blood coagulation.

    PubMed

    Riddel, James P; Aouizerat, Bradley E; Miaskowski, Christine; Lillicrap, David P

    2007-01-01

    Although the concept of the coagulation cascade represented a significant advance in the understanding of coagulation and served for many years as a useful model, more recent clinical and experimental observations demonstrate that the cascade/waterfall hypothesis does not fully and completely reflect the events of hemostasis in vivo. The goal of this article is to review the evolution of the theories of coagulation and their proposed models to serve as a tool when reviewing the research and practice literature that was published in the context of these different theories over time.

  9. Changes in the human blood coagulating system during prolonged hypokinesia

    NASA Technical Reports Server (NTRS)

    Filatova, L. M.; Anashkin, O. D.

    1978-01-01

    Changes in the coagulating system of the blood were studied in six subjects during prolonged hypokinesia. Thrombogenic properties of the blood rose in all cases on the 8th day. These changes are explained by stress reaction due to unusual conditions for a healthy person. Changes in the blood coagulating system in the group subjected to physical exercise and without it ran a practically parallel course. Apparently physical exercise is insufficient to prevent such changes that appear in the coagulating system of the blood during prolonged hypokinesia.

  10. Determining the efficiency of subjecting finely dispersed emulsions to physical coagulation in a packed layer under turbulent conditions

    NASA Astrophysics Data System (ADS)

    Laptev, A. G.; Basharov, M. M.; Farakhova, A. I.

    2013-09-01

    The process through which small droplets contained in emulsions are physically coagulated on the surface of random packing elements is considered. The theory of turbulent migration of a finely dispersed phase is used for determining the coagulation efficiency. Expressions for calculating coagulation efficiency and turbulent transfer rate are obtained by applying models of a turbulent boundary layer. An example of calculating the enlargement of water droplets in hydrocarbon medium represented by a wide fraction of light hydrocarbons (also known as natural gas liquid) is given. The process flowchart of a system for removing petroleum products from effluent waters discharged from the Kazan TETs-1 cogeneration station is considered. Replacement of the mechanical filter by a thin-layer settler with a coagulator is proposed.

  11. A preliminary study of continuous milk coagulation using Cynara cardunculus flower extract and calf rennet immobilized on magnetic particles.

    PubMed

    Liburdi, Katia; Emiliani Spinelli, Sara; Benucci, Ilaria; Lombardelli, Claudio; Esti, Marco

    2018-01-15

    The aim of this study was to develop a bioreactor design for continuous milk coagulation using a biocatalyst composed of immobilized animal and vegetable rennet on aminated magnetic particles, which has been proven to be an appropriate carrier for enzyme immobilization. Calf and vegetable (Cynara cardunculus) rennets were covalently immobilized on CLEA® magnetic supports and the immobilization procedure was optimized in batch mode, by evaluating protein loading, caseinolytic activity and the coagulation properties of skim milk powder and cow's milk. Subsequently the optimal temperature of immobilized coagulant was defined and a technically-friendly enzyme bioreactor was developed in order to carry out a continuous milk coagulation process with the aim of producing soft cheese. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Near-infrared fiber delivery systems for interstitial photothermal therapy

    NASA Astrophysics Data System (ADS)

    Slatkine, Michael; Mead, Douglass S.; Konwitz, Eli; Rosenberg, Zvi

    1995-05-01

    Interstitial photothermal coagulation has long been recognized as a potential important, minimally invasive modality for treating a variety of pathologic conditions. We present two different technologies for interstitial photothermal coagulation of tissue with infrared lasers: An optical fiber with a radially symmetric diffusing tip for deep coagulation, and a flat bare fiber for the coagulation of thin and long lesions by longitudinally moving the fiber while lasing in concert. Urology and Gynecology Fibers: The fibers are 600 microns diameter with 20 - 40 mm frosted distal tips protected by a smooth transparent cover. When used with a Neodymium:YAG (Nd:YAG) laser, the active fiber surface diffuses optical radiation in a radial pattern, delivering up to 40 W power, and thus providing consistent and uniform interstitial photothermal therapy. Coagulation depth ranges from 4 to 15 mm. Animal studies in the United States and clinical studies in Europe have demonstrated the feasibility of using these fibers to treat benign prostatic hyperplasia and endometrial coagulation. Rhinology Fiber: The fiber is an 800 micron diameter flat fiber operated at 8 W power level while being interstitially pushed and pulled along its axis. A long and thin coagulated zone is produced. The fiber is routinely used for the shrinking of hypertrophic turbinates without surrounding and bone mucusal damage in ambulatory environments.

  13. Monitoring and treatment of coagulation abnormalities in burn patients. an international survey on current practices

    PubMed Central

    Lavrentieva, A.; Depetris, N.; Kaimakamis, E.; Berardino, M.; Stella, M.

    2016-01-01

    Summary The magnitude of coagulation abnormalities, and the definition and treatment of coagulopathy in burn patients are inadequately understood and continue to be discussed in the literature. We aimed to analyse physicians’ views on monitoring and treating coagulation abnormalities in burn patients. A total of 350 questionnaires were distributed electronically to burn ICU physicians. Participation was voluntary and anonymous. Responses were analysed electronically and comparisons were made according to the region of the ICU or the specialty of the physician. Of the 350 questionnaires distributed, 55 (15.7%) were returned. The majority of burn specialists consider sepsis-induced coagulopathy to be the most frequent coagulopathy in burn patients, and 74.5% declare that they do not use any specific definition/scoring system in their department to detect coagulopathy. The majority of specialists (70.8%) use standard coagulation tests. The most frequent indications for plasma transfusion are massive bleeding (32.8%) and Disseminated Intravascular Coagulation syndrome treatment (20%). The main specific factors reported in our study are cryoprecipitate (23.2%) and fibrinogen concentrate (18.9%). 21.1% of respondents state that they do not use any specific coagulation factor substitution in burn patients. Specific coagulation factor substitution is not a routine practice. The low response rate precludes the generalization of our results. PMID:28149244

  14. Coagulation management in trauma-associated coagulopathy: allogenic blood products versus coagulation factor concentrates in trauma care.

    PubMed

    Klages, Matthias; Zacharowski, Kai; Weber, Christian Friedrich

    2016-04-01

    Coagulation management by transfusion of allogenic blood products and coagulation factors are competing concepts in current trauma care. Rapid and adequate therapy of trauma-associated coagulopathy is crucial to survival of severely injured patients. Standard coagulation tests such as prothrombin time and activated partial thromboplastin time are commonly used, but these tests are inappropriate for monitoring and guiding therapy in trauma patients. Coagulation factor-based treatment showed promising results, but randomized trials have not yet been performed. In addition, viscoelastic tests are needed to guide therapy, although there is in fact limited evidence for these in tests in trauma care. Regarding transfusion therapy with allogenic blood products, plasma transfusion has been associated with improved survival in trauma patients following massive transfusion. In contrast, patients not requiring massive transfusion seem to be at risk for suffering complications with increasing volumes of plasma transfused. The collective of trauma patients is heterogeneous. Despite the lack of evidence, there are strong arguments for individualized patient treatment with coagulation factors for some indications and to abstain from the use of fresh frozen plasma. In patients with severe trauma and major bleeding, plasma, platelets, and red blood cells should be considered to be administered at a ratio of 1 : 1 : 1.

  15. Multipurpose HTS Coagulation Analysis: Assay Development and Assessment of Coagulopathic Snake Venoms

    PubMed Central

    Still, Kristina B. M.; Nandlal, Randjana S. S.; Slagboom, Julien; Somsen, Govert W.; Kool, Jeroen

    2017-01-01

    Coagulation assays currently employed are often low throughput, require specialized equipment and/or require large blood/plasma samples. This study describes the development, optimization and early application of a generic low-volume and high-throughput screening (HTS) assay for coagulation activity. The assay is a time-course spectrophotometric measurement which kinetically measures the clotting profile of bovine or human plasma incubated with Ca2+ and a test compound. The HTS assay can be a valuable new tool for coagulation diagnostics in hospitals, for research in coagulation disorders, for drug discovery and for venom research. A major effect following envenomation by many venomous snakes is perturbation of blood coagulation caused by haemotoxic compounds present in the venom. These compounds, such as anticoagulants, are potential leads in drug discovery for cardiovascular diseases. The assay was implemented in an integrated analytical approach consisting of reversed-phase liquid chromatography (LC) for separation of crude venom components in combination with parallel post-column coagulation screening and mass spectrometry (MS). The approach was applied for the rapid assessment and identification of profiles of haemotoxic compounds in snake venoms. Procoagulant and anticoagulant activities were correlated with accurate masses from the parallel MS measurements, facilitating the detection of peptides showing strong anticoagulant activity. PMID:29186818

  16. Biological and analytical variations of 16 parameters related to coagulation screening tests and the activity of coagulation factors.

    PubMed

    Chen, Qian; Shou, Weiling; Wu, Wei; Guo, Ye; Zhang, Yujuan; Huang, Chunmei; Cui, Wei

    2015-04-01

    To accurately estimate longitudinal changes in individuals, it is important to take into consideration the biological variability of the measurement. The few studies available on the biological variations of coagulation parameters are mostly outdated. We confirmed the published results using modern, fully automated methods. Furthermore, we added data for additional coagulation parameters. At 8:00 am, 12:00 pm, and 4:00 pm on days 1, 3, and 5, venous blood was collected from 31 healthy volunteers. A total of 16 parameters related to coagulation screening tests as well as the activity of coagulation factors were analyzed; these included prothrombin time, fibrinogen (Fbg), activated partial thromboplastin time, thrombin time, international normalized ratio, prothrombin time activity, activated partial thromboplastin time ratio, fibrin(-ogen) degradation products, as well as the activity of factor II, factor V, factor VII, factor VIII, factor IX, and factor X. All intraindividual coefficients of variation (CVI) values for the parameters of the screening tests (except Fbg) were less than 5%. Conversely, the CVI values for the activity of coagulation factors were all greater than 5%. In addition, we calculated the reference change value to determine whether a significant difference exists between two test results from the same individual. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. [Combined use of active chlorine and coagulants for drinking water purification and disinfection].

    PubMed

    Rakhmanin, Iu A; Zholdakova, Z I; Poliakova, E E; Kir'ianova, L F; Miasnikov, I N; Tul'skaia, E A; Artemova, T Z; Ivanova, L V; Dmitrieva, R A; Doskina, T V

    2004-01-01

    The authors made an experimental study of the efficiency of water purification procedures based on the combined use of active chlorine and coagulants and hygienically evaluated the procedures. The study included the evaluation of water disinfection with various coagulants and active chlorine; the investigation of the processes of production of deleterious organic chlorine compounds; the assessment of the quality of water after its treatment. The coagulants representing aluminum polyoxychloride: RAX-10 (AQUA-AURATE 10) and RAX-18 (AQUA-AURATE 18), and aluminum sulfate, technically pure grade were tested. The treatment of river water with the coagulants RAX-10 and RAX-18, followed by precipitation, filtration, and chlorination under laboratory conditions, was shown to result in water disinfection to the levels complying with the requirements described in SanPiN 2.1.4.1074-01. RAX-18 showed the best disinfecting activity against total and heat-tolerant coliform bacteria, but also to the highly chlorine-resistant microrganisms--the spores of sulfite-reducing Clostridia, phages, and viruses. Since the coagulants have an increased sorptive capacity relative to humus and other organic substances, substitution of primary chlorination for coagulant treatment may induce a reduction in the risk of formation of oncogenically and mutagenically hazardous chlorinated hydrocarbons.

  18. Effect of circulating tissue factor on hypercoagulability in type 2 diabetes mellitus studied by rheometry and dielectric blood coagulometry

    PubMed Central

    Uchimura, Isao; Kaibara, Makoto; Nagasawa, Masayuki; Hayashi, Yoshihito

    2016-01-01

    Background: Hypercoagulability in type 2 diabetes mellitus (T2DM) patients increases their risk of cardiovascular diseases. Objective: The aim of this work was to investigate the hypercoagulation mechanism in T2DM patients in terms of circulating tissue factor (TF). Methods: Whole blood coagulation tests by damped oscillation rheometry and dielectric blood coagulometry (DBCM) were performed. Results: The average coagulation time was significantly shorter for T2DM patients than for healthy controls. In vitro addition of either anti-TF or anti-activated factor VII (FVIIa) antibody to hypercoagulable blood samples prolonged coagulation times for one group of patients, while coagulation times remained short for another group. The levels of circulating TF were estimated in the former group by measuring the coagulation times for blood samples from healthy subjects with addition of various concentrations of TF and comparing them with the coagulation times for the group. The results indicated that the levels of circulating TF were on the order of subpicomolar at most. Conclusions: Circulating TF is at least partially responsible for a hypercoagulable group of T2DM patients, while an abnormality in the intrinsic coagulation pathway probably occurs in the other group. PMID:27858671

  19. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode.

    PubMed

    Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju

    2015-11-16

    Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.

  20. The impact of pre-oxidation with potassium permanganate on cyanobacterial organic matter removal by coagulation.

    PubMed

    Naceradska, Jana; Pivokonsky, Martin; Pivokonska, Lenka; Baresova, Magdalena; Henderson, Rita K; Zamyadi, Arash; Janda, Vaclav

    2017-05-01

    The study investigates the effect of permanganate pre-oxidation on the coagulation of peptides/proteins of Microcystis aeruginosa which comprise a major proportion of the organic matter during cyanobacterial bloom decay. Four different permanganate dosages (0.1, 0.2, 0.4 and 0.6 mg KMnO 4 mg -1 DOC) were applied prior to coagulation by ferric sulphate. Moreover, changes in sample characteristics, such as UV 254 , DOC content and molecular weight distribution, after pre-oxidation were monitored. The results showed that permanganate pre-oxidation led to a reduction in coagulant dose, increased organic matter removals by coagulation (by 5-12% depending on permanganate dose), microcystin removal (with reductions of 91-96%) and a shift of the optimum pH range from 4.3 to 6 without to 5.5-7.3 with pre-oxidation. Degradation of organic matter into inorganic carbon and adsorption of organic matter onto hydrous MnO 2 are suggested as the main processes responsible for coagulation improvement. Moreover, permanganate prevented the formation of Fe-peptide/protein complexes that inhibit coagulation at pH about 6.2 without pre-oxidation. The study showed that carefully optimized dosing of permanganate improves cyanobacterial peptide/protein removal, with the benefit of microcystin elimination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode

    NASA Astrophysics Data System (ADS)

    Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju

    2015-11-01

    Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.

  2. Accelerating population balance-Monte Carlo simulation for coagulation dynamics from the Markov jump model, stochastic algorithm and GPU parallel computing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Zuwei; Zhao, Haibo, E-mail: klinsmannzhb@163.com; Zheng, Chuguang

    2015-01-15

    This paper proposes a comprehensive framework for accelerating population balance-Monte Carlo (PBMC) simulation of particle coagulation dynamics. By combining Markov jump model, weighted majorant kernel and GPU (graphics processing unit) parallel computing, a significant gain in computational efficiency is achieved. The Markov jump model constructs a coagulation-rule matrix of differentially-weighted simulation particles, so as to capture the time evolution of particle size distribution with low statistical noise over the full size range and as far as possible to reduce the number of time loopings. Here three coagulation rules are highlighted and it is found that constructing appropriate coagulation rule providesmore » a route to attain the compromise between accuracy and cost of PBMC methods. Further, in order to avoid double looping over all simulation particles when considering the two-particle events (typically, particle coagulation), the weighted majorant kernel is introduced to estimate the maximum coagulation rates being used for acceptance–rejection processes by single-looping over all particles, and meanwhile the mean time-step of coagulation event is estimated by summing the coagulation kernels of rejected and accepted particle pairs. The computational load of these fast differentially-weighted PBMC simulations (based on the Markov jump model) is reduced greatly to be proportional to the number of simulation particles in a zero-dimensional system (single cell). Finally, for a spatially inhomogeneous multi-dimensional (multi-cell) simulation, the proposed fast PBMC is performed in each cell, and multiple cells are parallel processed by multi-cores on a GPU that can implement the massively threaded data-parallel tasks to obtain remarkable speedup ratio (comparing with CPU computation, the speedup ratio of GPU parallel computing is as high as 200 in a case of 100 cells with 10 000 simulation particles per cell). These accelerating approaches of PBMC are demonstrated in a physically realistic Brownian coagulation case. The computational accuracy is validated with benchmark solution of discrete-sectional method. The simulation results show that the comprehensive approach can attain very favorable improvement in cost without sacrificing computational accuracy.« less

  3. No effect of isolated long-term supine immobilization or profound prolonged hypoxia on blood coagulation.

    PubMed

    Venemans-Jellema, A; Schreijer, A J M; Le Cessie, S; Emmerich, J; Rosendaal, F R; Cannegieter, S C

    2014-06-01

    Long-distance air travel is associated with an increased risk of venous thrombosis. The most obvious factor that can explain air travel-related thrombosis is prolonged seated immobilization. In addition, hypobaric hypoxia has been shown to affect coagulation, and the lowered atmospheric pressures present in the cabin during the flight may therefore play an etiologic role. Because immobilization and hypoxic conditions are usually present simultaneously in airplanes or hypobaric chambers, their separate effects on the coagulation system or on thrombosis risk have not been studied extensively. To investigate the separate effects of long-term immobilization and profound prolonged hypoxia on blood coagulation. We performed two studies in collaboration with European Space Agency/European Space Research and Technology Centre. In the first study, 24 healthy, non-smoking, adult women underwent 60 days of -6° head-down bed rest. In the second study, we took blood samples from 25 healthy men who participated during their stay in the Concordia station in Antarctica, where, due to the atmospheric conditions, continuous severe hypobaric hypoxia is present. In both studies, we measured markers of blood coagulation at baseline and at several time points during the exposures. We observed no increase in coagulation markers during immobilization or in the hypobaric environment, compared with baseline measurements. Our results indicate that neither immobilization nor hypoxia per se affects blood coagulation. These results implicate that a combination of risk factors is necessary to induce the coagulation system during air travel. © 2014 International Society on Thrombosis and Haemostasis.

  4. Using the Electronic Medical Record to Reduce Unnecessary Ordering of Coagulation Studies for Patients with Chest Pain

    PubMed Central

    Hinson, Jeremiah S.; Mistry, Binoy; Hsieh, Yu-Hsiang; Risko, Nicholas; Scordino, David; Paziana, Karolina; Peterson, Susan; Omron, Rodney

    2017-01-01

    Introduction Our goal was to reduce ordering of coagulation studies in the emergency department (ED) that have no added value for patients presenting with chest pain. We hypothesized this could be achieved via implementation of a stopgap measure in the electronic medical record (EMR). Methods We used a pre and post quasi-experimental study design to evaluate the impact of an EMR-based intervention on coagulation study ordering for patients with chest pain. A simple interactive prompt was incorporated into the EMR of our ED that required clinicians to indicate whether patients were on anticoagulation therapy prior to completion of orders for coagulation studies. Coagulation order frequency was measured via detailed review of randomly sampled encounters during two-month periods before and after intervention. We classified existing orders as clinically indicated or non-value added. Order frequencies were calculated as percentages, and we assessed differences between groups by chi-square analysis. Results Pre-intervention, 73.8% (76/103) of patients with chest pain had coagulation studies ordered, of which 67.1% (51/76) were non-value added. Post-intervention, 38.5% (40/104) of patients with chest pain had coagulation studies ordered, of which 60% (24/40) were non-value added. There was an absolute reduction of 35.3% (95% confidence interval [CI]: 22.7%, 48.0%) in the total ordering of coagulation studies and 26.4% (95% CI: 13.8%, 39.0%) in non-value added order placement. Conclusion Simple EMR-based interactive prompts can serve as effective deterrents to indiscriminate ordering of diagnostic studies. PMID:28210363

  5. Using the Electronic Medical Record to Reduce Unnecessary Ordering of Coagulation Studies for Patients with Chest Pain.

    PubMed

    Hinson, Jeremiah S; Mistry, Binoy; Hsieh, Yu-Hsiang; Risko, Nicholas; Scordino, David; Paziana, Karolina; Peterson, Susan; Omron, Rodney

    2017-02-01

    Our goal was to reduce ordering of coagulation studies in the emergency department (ED) that have no added value for patients presenting with chest pain. We hypothesized this could be achieved via implementation of a stopgap measure in the electronic medical record (EMR). We used a pre and post quasi-experimental study design to evaluate the impact of an EMR-based intervention on coagulation study ordering for patients with chest pain. A simple interactive prompt was incorporated into the EMR of our ED that required clinicians to indicate whether patients were on anticoagulation therapy prior to completion of orders for coagulation studies. Coagulation order frequency was measured via detailed review of randomly sampled encounters during two-month periods before and after intervention. We classified existing orders as clinically indicated or non-value added. Order frequencies were calculated as percentages, and we assessed differences between groups by chi-square analysis. Pre-intervention, 73.8% (76/103) of patients with chest pain had coagulation studies ordered, of which 67.1% (51/76) were non-value added. Post-intervention, 38.5% (40/104) of patients with chest pain had coagulation studies ordered, of which 60% (24/40) were non-value added. There was an absolute reduction of 35.3% (95% confidence interval [CI]: 22.7%, 48.0%) in the total ordering of coagulation studies and 26.4% (95% CI: 13.8%, 39.0%) in non-value added order placement. Simple EMR-based interactive prompts can serve as effective deterrents to indiscriminate ordering of diagnostic studies.

  6. Matriptase activation connects tissue factor-dependent coagulation initiation to epithelial proteolysis and signaling.

    PubMed

    Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric

    2016-06-23

    The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation.

  7. Coagulation is more affected by quick than slow bleeding in patients with massive blood loss.

    PubMed

    Zhao, Juan; Yang, Dejuan; Zheng, Dongyou

    2017-03-01

    Profuse blood loss affects blood coagulation to various degrees. However, whether bleeding speed affects coagulation remains uncertain. This study aimed to evaluate the effect of bleeding speed on coagulation function. A total of 141 patients in the Department of Thoracic Surgery of our hospital were evaluated between January 2007 and February 2014. There are two groups of patients, those who received decortication for chronic encapsulated empyema were called the slow-bleeding group, and those who received thoracoscopic upper lobectomy were called the fast bleeding group; each group was further subdivided into three: group A, 1000 ml ≤ bleeding amount < 1500 ml; group B, 1500 ml ≤ bleeding amount < 1700 ml; group C, 1700 ml ≤ bleeding amount < 2000 ml. Then, coagulation function was assessed in all patients before and during surgery and at 1, 2, and 24 h after surgery, measuring prothrombin time, activated partial thromboplastin time (APTT), fibrinogen, blood pressure, hematocrit, hemoglobin, and platelets. Bleeding duration was overtly longer in the slow-bleeding group than that in quick bleeding individuals (2.3 ± 0.25 h vs. 0.41 ± 0.13 h, P < 0.001). Fibrinogen, hematocrit, hemoglobin, and platelets strikingly decreased, whereas prothrombin time and APTT values significantly increased with bleeding amounts in both quick and slow-bleeding groups. Interestingly, compared with slow-bleeding patients, coagulation indices at each time point and bleeding amounts had significant differences in the quick bleeding group.Increased consumption of coagulation factors in quick bleeding may have greater impact on coagulation function.

  8. Anti-Coagulant and Anti-Thrombotic Properties of Blacklip Abalone (Haliotis rubra): In Vitro and Animal Studies

    PubMed Central

    Masci, Paul P.; Zhao, Kong-Nan; Addepalli, Rama; Chen, Wei; Osborne, Simone A.; Gobe, Glenda C.

    2017-01-01

    Sulphated polysaccharides with anti-thrombotic and anti-coagulant activities have been found in various marine biota. In this study, a previously characterised anti-thrombotic and anti-coagulant extract from blacklip abalone was fractionated by anion exchange chromatography (AEC), pooled (on a sulphated polysaccharide basis) and administered to Wistar rats via oral gavage (N = 8) for assessment as an oral therapeutic. To ensure that the preparation had anti-coagulant activity prior to oral administration, it was assessed in rat blood by thromboelastography (TEG) significantly increasing reaction (R) time (or time until clot formation). Following in vitro confirmation of anti-coagulant activity, 40 mg of the preparation was orally administered to rats with blood samples collected at 2, 4, and 6 h post-gavage. Assessment of all blood samples by TEG showed some prolongation of R time from 355 to 380 s after 4 h. Dosing of the post-gavage blood samples with the abalone preparation to confirm anti-thrombotic activity in vitro revealed residual anti-coagulant activity, further suggesting that oral administration did increase anti-coagulant potential in the collected blood but that bioavailability was low. Assessment of tissues and haematological parameters showed no obvious harmful effects of the abalone preparation in animals. In summary, even though oral administration of fractionated and pooled blacklip abalone extract to rats delayed clotting after 4 h, bioavailability of the preparation appeared to be low and may be more appropriate for intravenous administration as an anti-thrombotic or anti-coagulant therapeutic. PMID:28777290

  9. Effect of adsorbent addition on floc formation and clarification.

    PubMed

    Younker, Jessica M; Walsh, Margaret E

    2016-07-01

    Adding adsorbent into the coagulation process is an emerging treatment solution for targeting hard-to-remove dissolved organic compounds from both drinking water and industrial wastewater. The impact of adding powdered activated carbon (PAC) or organoclay (OC) adsorbents with ferric chloride (FeCl3) coagulant was investigated in terms of potential changes to the coagulated flocs formed with respect to size, structure, and breakage and regrowth properties. The ability of dissolved air flotation (DAF) and sedimentation (SED) clarification processes to remove hybrid adsorbent-coagulant flocs was also evaluated through clarified water quality analysis of samples collected in bench-scale jar test experiments. The jar tests were conducted using both a synthetic fresh water and oily wastewater test water spiked with dissolved aromatic compounds phenol and naphthalene. Results of the study demonstrated that addition of adsorbent reduced the median coagulated floc size by up to 50% but did not affect floc strength or regrowth potential after application of high shear. Experimental results in fresh water demonstrated that sedimentation was more effective than DAF for clarification of both FeCl3-PAC and FeCl3-OC floc aggregates. However, experimental tests performed on the synthetic oily wastewater showed that coagulant-adsorbent floc aggregates were effectively removed with both DAF and sedimentation treatment, with lower residual turbidity achieved in clarified water samples than with coagulation treatment alone. Addition of OC or PAC into the coagulation process resulted in removals of over half, or nearly all of the dissolved aromatics, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. The effectiveness of coagulation for water reclamation from a wastewater treatment plant that has a long hydraulic and sludge retention times: A case study.

    PubMed

    Cui, Xiaochun; Zhou, Dandan; Fan, Wei; Huo, Mingxin; Crittenden, John C; Yu, Zhisen; Ju, Pengfei; Wang, Yang

    2016-08-01

    Coagulation is a feasible process to reclaim municipal wastewater, however, the role of coagulation in removing effluent organic matter (EfOM) from underutilized wastewater treatment plants (WWTPs) has not been fully explored. We identified the characteristics of the EfOM from a typical underutilized WWTP (i.e., the ratio of actual capacity to design capacity is 50%-70%), and investigated the performance of coagulation on suspended solids (SS) and dissolved organic matter (DOM) removal. The effluent could even satisfy the highest national standard of China (Class 1 A) for WWTP effluent, as evaluated by the traditional parameters such as SS and chemical oxygen demand (COD). However, the DOM in the EfOM we studied contained considerable biomass-associated products (BAPs), which were dominated by proteins with a molecular weight of approximately 150 kDa. In addition, protein also dominated the DOM after coagulation. Fulvic acid and humic-like acid organics were poorly removed by either AlCl3 or polyaluminum chloride (PAC) coagulation, even with a dosage as high as 24 mg Al L(-1). Biodegradability was very poor, as the ratio of biological oxygen demand (BOD5) to COD was less than 0.17. After coagulation the typical BAPs, protein and polysaccharide, remained as high as 1.6 mg L(-1) and 1.2 mg L(-1) respectively. In this study we found coagulation was ineffective for removal of recalcitrant BAPs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Membrane fouling control and enhanced removal of pharmaceuticals and personal care products by coagulation-MBR.

    PubMed

    Park, Junwon; Yamashita, Naoyuki; Tanaka, Hiroaki

    2018-04-01

    We investigated the effects of the addition of two coagulants-polyaluminium chloride (PACl) and chitosan-into the membrane bioreactor (MBR) process on membrane fouling and the removal of pharmaceuticals and personal care products (PPCPs). Their addition at optimized dosages improved the permeability of the membrane by reducing the concentration of soluble microbial products in mixed liquor, the content of inorganic elements, and irreversible fouling of the membrane surface. During long-term operation, the addition of PACl increased removal efficiencies of tetracycline, mefenamic acid, atenolol, furosemide, ketoprofen, and diclofenac by 17-23%. The comparative evaluation using mass balance calculations between coagulation-MBR (with PACl addition) and control-MBR (without PACl addition) showed that enhanced biodegradability played a key role in improving removal efficiencies of some PPCPs in coagulation-MBR. Coagulation-MBR also had higher oxygen uptake rates and specific nitrification rates of microorganisms. Overall, our findings suggest that the combination of MBR with coagulation reduced membrane fouling, lengthening operation period of the membrane, and improved the removal of some PPCPs as a result of enhanced biodegradability. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Bacteroidaceae in Thromboembolic Disease: Effects of Cell Wall Components on Blood Coagulation In Vivo and In Vitro

    PubMed Central

    Bjornson, H. S.; Hill, E. O.

    1973-01-01

    The effects of Bacteroides sp., Fusobacterium mortiferum, Bacteroides fragilis, and Sphaerophorus necrophorus on various parameters of blood coagulation in vivo and in vitro were determined and compared to the coagulation effects of Escherichia coli and Salmonella minnesota, wild type and R595. Intravenous injection of washed cells, culture filtrate, lipopolysaccharide, or lipid A of the anaerobic gram-negative microorganisms into mice resulted in acceleration of coagulation. Lipopolysaccharide and lipid A of the anaerobic microorganisms had no apparent effect on circulating platelets in mice or rabbits and did not cause aggregation of human platelets in vitro. Washed cells, lipopolysaccharide, and lipid A of Bacteroides sp. and F. mortiferum also significantly accelerated the clotting time of recalcified platelet poor normal human plasma and C6-deficient rabbit plasma. Lipid A, but not lipopolysaccharide, of E. coli and washed cells of S. minnesota R595 accelerated coagulation by a similar mechanism. These results indicated that Bacteroides sp. and F. mortiferum can accelerate blood coagulation in vivo and in vitro by a mechanism which does not involve platelets or terminal components of complement. PMID:4594118

  13. Micro- and mesoscopic process interactions in protein coagulation

    NASA Astrophysics Data System (ADS)

    San Biagio, P. L.; Martorana, V.; Emanuele, A.; Vaiana, S. M.; Manno, M.; Bulone, D.; Palma-Vittorelli, M. B.; Palma, M. U.

    2000-04-01

    It has recently been recognized that pathological protein coagulation is responsible for lethal pathologies as diverse as amyloidosis, Alzheimer and TSE. Understanding the coagulation mechanisms is therefore stirring great interest. In previous studies we have shown that on profoundly different systems coagulation is the result of a strong interaction between two processes on different length scales (mesoscopic and microscopic). Here we report experiments on bovine serum albumin (BSA) showing that the overall mechanism is the result of at least 3 distinct and strongly intertwined processes, on both length scales: molecular conformational changes, solution demixing and intermolecular crosslinking. This mechanism involves the statistical mechanics of protein-solvent interaction, its relation to the protein's landscape of configurational free energy and to the solution's thermodynamic stability, and its relation to the topological problem of crosslink-percolation, responsible for coagulation.

  14. Life-threatening urethral hemorrhage after placement of a Foley catheter in a patient with uroseptic disseminated intravascular coagulation due to chronic urinary retention induced by untreated benign prostatic hyperplasia.

    PubMed

    Ikegami, Yukihiro; Yoshida, Keisuke; Imaizumi, Tsuyoshi; Isosu, Tsuyoshi; Kurosawa, Shin; Murakawa, Masahiro

    2016-10-01

    A 77-year-old man with severe septic disseminated intravascular coagulation following urinary infection was transported to our hospital. He had developed urinary retention induced by untreated prostatic hyperplasia. Immediate drainage with a Foley catheter was successfully carried out, but the hematuria progressed to life-threatening hemorrhage. Complete hemostasis was impossible by surgical treatment because the tissue around the prostatic urethra was very fragile and hemorrhagic. Organized treatments (continuous hemodiafiltration combined with polymyxin-B immobilized fiber column hemoperfusion and systemic treatment with antibiotics and coagulation factors) were commenced soon after the operation. The patient eventually recovered from the septic disseminated intravascular coagulation. This case report illustrates the risk of placement of Foley catheters in patients with severe septic disseminated intravascular coagulation.

  15. Genetic Factors Influencing Coagulation Factor XIII B-Subunit Contribute to Risk of Ischemic Stroke.

    PubMed

    Hanscombe, Ken B; Traylor, Matthew; Hysi, Pirro G; Bevan, Stephen; Dichgans, Martin; Rothwell, Peter M; Worrall, Bradford B; Seshadri, Sudha; Sudlow, Cathie; Williams, Frances M K; Markus, Hugh S; Lewis, Cathryn M

    2015-08-01

    Abnormal coagulation has been implicated in the pathogenesis of ischemic stroke, but how this association is mediated and whether it differs between ischemic stroke subtypes is unknown. We determined the shared genetic risk between 14 coagulation factors and ischemic stroke and its subtypes. Using genome-wide association study results for 14 coagulation factors from the population-based TwinsUK sample (N≈2000 for each factor), meta-analysis results from the METASTROKE consortium ischemic stroke genome-wide association study (12 389 cases, 62 004 controls), and genotype data for 9520 individuals from the WTCCC2 ischemic stroke study (3548 cases, 5972 controls-the largest METASTROKE subsample), we explored shared genetic risk for coagulation and stroke. We performed three analyses: (1) a test for excess concordance (or discordance) in single nucleotide polymorphism effect direction across coagulation and stroke, (2) an estimation of the joint effect of multiple coagulation-associated single nucleotide polymorphisms in stroke, and (3) an evaluation of common genetic risk between coagulation and stroke. One coagulation factor, factor XIII subunit B (FXIIIB), showed consistent effects in the concordance analysis, the estimation of polygenic risk, and the validation with genotype data, with associations specific to the cardioembolic stroke subtype. Effect directions for FXIIIB-associated single nucleotide polymorphisms were significantly discordant with cardioembolic disease (smallest P=5.7×10(-04)); the joint effect of FXIIIB-associated single nucleotide polymorphisms was significantly predictive of ischemic stroke (smallest P=1.8×10(-04)) and the cardioembolic subtype (smallest P=1.7×10(-04)). We found substantial negative genetic covariation between FXIIIB and ischemic stroke (rG=-0.71, P=0.01) and the cardioembolic subtype (rG=-0.80, P=0.03). Genetic markers associated with low FXIIIB levels increase risk of ischemic stroke cardioembolic subtype. © 2015 The Authors.

  16. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients

    PubMed Central

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-01-01

    Abstract Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests. Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed. The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values. Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients. PMID:27311005

  17. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients.

    PubMed

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-06-01

    Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests.Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed.The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values.Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients.

  18. Removal of Arsenic from Drinking Water by Adsorption and Coagulation

    NASA Astrophysics Data System (ADS)

    Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.

    2013-12-01

    Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment, Arsenic, Adsorption, Coagulation, Drinking Water, Bangladesh

  19. Performance of alum and assorted coagulants in turbidity removal of muddy water

    NASA Astrophysics Data System (ADS)

    Malik, Qasim H.

    2018-03-01

    Coagulation is a primary and cost effective process in water treatment plants. Under optimum conditions, not only it effectively removes turbidity but also results in reduced sludge volume and subsequently minimizes sludge management costs. Highly turbid water from streams, canals, rivers and rain run offs was run through jar test for turbidity removal. The brown water with 250NTU turbidity when coagulated with alum and assorted coagulants proved that maximum turbidity removal was witnessed using alum dose of 0.25 g/l at ph 6 with a sedimentation time of 30 min.

  20. Dust coagulation in ISM

    NASA Technical Reports Server (NTRS)

    Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David

    1989-01-01

    Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.

  1. Coagulation abnormalities in pediatric and adult patients after sclerotherapy or embolization of vascular anomalies.

    PubMed

    Mason, K P; Neufeld, E J; Karian, V E; Zurakowski, D; Koka, B V; Burrows, P E

    2001-12-01

    The purpose of our study was to examine the coagulation status in patients with vascular anomalies who had undergone sclerotherapy or embolization. Ours was a prospective pilot study of 29 patients who had undergone sclerotherapy or embolization of large vascular anomalies. Fibrinogen, platelet, and d-dimer levels and prothrombin time were obtained before, immediately after, and on the day after the procedure. Five patients with venous malformations had positive d-dimer levels before the procedure. A subgroup analysis revealed a relationship between the type of agent used and the change in coagulation status. Specifically, a positive relationship was found between the use of dehydrated alcohol or sodium tetradecyl sulfate and a disruption in coagulation profiles as evidenced by a decrease in platelets and fibrinogen, an increase in prothrombin time, and a conversion from negative to positive d-dimers. In contrast, sclerotherapy or embolization with cyanoacrylic, polyvinyl alcohol foam particles, or platinum microcoils was not associated with coagulation disturbances. The coagulation disturbances that occur in response to dehydrated alcohol or sodium tetradecyl sulfate sclerotherapy or embolization could compromise the patient's clotting ability. Patients who receive dehydrated alcohol or sodium tetradecyl sulfate during a preoperative sclerotherapy or embolization may experience coagulation disturbances that could increase the risk of bleeding, thrombosis, or hematoma. This patient population may benefit from the use of glue, foam, or coils as a substitute for dehydrated alcohol or sodium tetradecyl sulfate.

  2. Removal and transformation of effluent organic matter (EfOM) in biotreated textile wastewater by GAC/O3 pre-oxidation and enhanced coagulation.

    PubMed

    Qian, Feiyue; Sun, Xianbo; Liu, Yongdi; Xu, Hongyong

    2013-01-01

    GAC/O3 (ozonation in the presence of granular activated carbon) combined with enhanced coagulation was employed to process biotreated textile wastewater for possible reuse. The doses of ozone, GAC and coagulant were the variables studied for optimization. The effects of different treatment processes on effluent organic matter (EfOM) characteristics, including biodegradability, hydrophobic and hydrophilic nature, and apparent molecular weight (AMW) distribution were also investigated. Compared with ozonation, GAC/O3 not only presented a higher pre-oxidation efficiency, but also improved the treatability of hydrophobic and high molecular weight compounds by enhanced coagulation. After treatment by GAC/O3 pre-oxidation (0.6 mg O3 x mg(-1) COD and 20 g x L(-1) GAC) and enhanced coagulation (25 mg x L(-1) Al3+ at pH 5.5), the removal efficiencies of chemical oxygen demand (COD), dissolved organic carbon (DOC) and colour were higher than those for coagulation alone by 17.3%, 12.0% and 25.6%, respectively. Residual organic matter consisted mainly of hydrophobic acids and hydrophilic compounds of AMW < 1 kDa, which were colourless and of limited biological availability. The combination of GAC/O3 and enhanced coagulation was proved to be a simple and effective treatment strategy for removing EfOM from biotreated textile wastewater.

  3. Evaluation of Optical Coherence Tomography for the Measurement of the Effects of Activators and Anticoagulants on the Blood Coagulation In Vitro

    PubMed Central

    Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-01-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d1/e) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening. PMID:23392340

  4. Evaluation of optical coherence tomography for the measurement of the effects of activators and anticoagulants on the blood coagulation in vitro.

    PubMed

    Xu, Xiangqun; Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-08-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d(1/e)) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening.

  5. C-1s NEXAFS spectroscopy reveals chemical fractionation of humic acid by cation-induced coagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christl,I.; Kretzschmar, R.

    2007-01-01

    The influence of cation-induced coagulation on the chemical composition of dissolved and coagulated fractions of humic acid was investigated in batch coagulation experiments for additions of aluminum at pH 4 and 5, iron at pH 4, and calcium and lead at pH 6. The partitioning of organic carbon and metals was determined by analyzing total organic carbon and total metal contents of the dissolved phase. Both the dissolved and the coagulated humic acid fractions were characterized using synchrotron scanning transmission X-ray microscopy (STXM) and C-1s near-edge X-ray absorption fine structure (NEXAFS) spectroscopy. Intensities of {pi}* transitions of carboxyl carbon andmore » {sigma}* transitions of alkyl, O-alkyl, and carboxyl carbon decreased with increasing metal concentration for the dissolved humic acid fractions. This decrease was accompanied by an increase of the respective intensities in the coagulated fraction as shown for lead. Intensities of aromatic and phenolic carbon were affected to a larger extent only by aluminum and iron additions. The changes observed in the C-1s NEXAFS spectra coincided with an increasing removal of organic carbon from the dissolved phase with increasing total metal concentrations. We conclude that humic acid was chemically fractionated by cation-induced coagulation, which preferentially removed functional groups involved in metal-cation binding from solution.« less

  6. Alterations in Blood Coagulation and Viscosity Among Young Male Cigarette Smokers of Al-Jouf Region in Saudi Arabia.

    PubMed

    Almarshad, Hassan A; Hassan, Fathelrahman M

    2016-05-01

    Hemorheology, a measure of rheological properties of blood, is often correlated with cerebral blood flow and cardiac output; an increased blood viscosity may increase the risk of thrombosis or thromboembolic events. Previous studies have reported a large variation in hemorheological properties of blood among smokers. This prompted us to conduct coagulation experiments to evaluate the effect of cigarette smoking on hematological parameters, like cell counts, and coagulation parameters among young males in Al-Jouf region, Saudi Arabia. The hematological and coagulation parameters were used to relate the changes in viscosity and coagulation to smoking. A total of 321 male participants (126 nonsmokers and 195 smokers) were enrolled into the study as randomized sample. Complete blood count was measured by hematology analyzer, and coagulation tests were performed by coagulation analyzer. Thettest analysis was performed to compare the relationships of variables between the 2 groups. The results confirmed that smoking alters some hematology parameters leading to significant deterioration in blood flow properties. Smoking also increased the hematocrit (HCT), whole blood viscosity (WBV), and plasma viscosity (PV) but decreased the international normalized ratio (INR). The decrease in INR was found to be associated with the increase in WBV, PV, and HCT. Further investigations are necessary to assess the reversibility of such changes in cessation of smoking or other elements of influence. © The Author(s) 2014.

  7. Does whole blood coagulation analysis reflect developmental haemostasis?

    PubMed

    Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette

    2017-04-01

    : Developmental haemostasis has been well documented over the last 3 decades and age-dependent reference ranges have been reported for a number of plasmatic coagulation parameters. With the increasing use of whole blood point-of-care tests like rotational thromboelastometry (ROTEM) and platelet function tests, an evaluation of age-dependent changes is warranted for these tests as well. We obtained blood samples from 149 children, aged 1 day to 5.9 years, and analysed conventional plasmatic coagulation tests, including activated partial prothrombin time, prothrombin time, and fibrinogen (functional). Whole blood samples were analysed using ROTEM to assess overall coagulation capacity and Multiplate analyzer to evaluate platelet aggregation. Age-dependent changes were analysed for all variables. We found age-dependent differences in all conventional coagulation tests (all P values < 0.05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P < 0.03). Despite marked differences in mean platelet aggregation between age groups, data did not reach statistical significance. Citrate-anticoagulated blood showed significantly reduced platelet aggregation compared with blood anticoagulated with heparin or hirudin (all P values < 0.003). We confirmed previous developmental changes in conventional plasmatic coagulation test. However, these age-dependent changes were not displayed in whole blood monitoring using ROTEM or Multiplate analyzer. Type of anticoagulant had a significant influence on platelet aggregation across all age groups.

  8. Dust Coagulation in Protoplanetary Accretion Disks

    NASA Technical Reports Server (NTRS)

    Schmitt, W.; Henning, Th.; Mucha, R.

    1996-01-01

    The time evolution of dust particles in circumstellar disk-like structures around protostars and young stellar objects is discussed. In particular, we consider the coagulation of grains due to collisional aggregation. The coagulation of the particles is calculated by solving numerically the non-linear Smoluchowski equation. The different physical processes leading to relative velocities between the grains are investigated. The relative velocities may be induced by Brownian motion, turbulence and drift motion. Starting from different regimes which can be identified during the grain growth we also discuss the evolution of dust opacities. These opacities are important for both the derivation of the circumstellar dust mass from submillimeter/millimeter continuum observations and the dynamical behavior of the disks. We present results of our numerical studies of the coagulation of dust grains in a turbulent protoplanetary accretion disk described by a time-dependent one-dimensional (radial) alpha-model. For several periods and disk radii, mass distributions of coagulated grains have been calculated. From these mass spectra, we determined the corresponding Rosseland mean dust opacities. The influence of grain opacity changes due to dust coagulation on the dynamical evolution of a protostellar disk is considered. Significant changes in the thermal structure of the protoplanetary nebula are observed. A 'gap' in the accretion disk forms at the very frontier of the coagulation, i.e., behind the sublimation boundary in the region between 1 and 5 AU.

  9. Positive Feedback Loops for Factor V and Factor VII Activation Supply Sensitivity to Local Surface Tissue Factor Density During Blood Coagulation

    PubMed Central

    Balandina, A.N.; Shibeko, A.M.; Kireev, D.A.; Novikova, A.A.; Shmirev, I.I.; Panteleev, M.A.; Ataullakhanov, F.I.

    2011-01-01

    Blood coagulation is triggered not only by surface tissue factor (TF) density but also by surface TF distribution. We investigated recognition of surface TF distribution patterns during blood coagulation and identified the underlying molecular mechanisms. For these investigations, we employed 1), an in vitro reaction-diffusion experimental model of coagulation; and 2), numerical simulations using a mathematical model of coagulation in a three-dimensional space. When TF was uniformly immobilized over the activating surface, the clotting initiation time in normal plasma increased from 4 min to >120 min, with a decrease in TF density from 100 to 0.7 pmol/m2. In contrast, surface-immobilized fibroblasts initiated clotting within 3–7 min, independently of fibroblast quantity and despite a change in average surface TF density from 0.5 to 130 pmol/m2. Experiments using factor V-, VII-, and VIII-deficient plasma and computer simulations demonstrated that different responses to these two TF distributions are caused by two positive feedback loops in the blood coagulation network: activation of the TF–VII complex by factor Xa, and activation of factor V by thrombin. This finding suggests a new role for these reactions: to supply sensitivity to local TF density during blood coagulation. PMID:22004734

  10. TREATMENT OF LANDFILL LEACHATE BY COUPLING COAGULATION-FLOCCULATION OR OZONATION TO GRANULAR ACTIVATED CARBON ADSORPTION.

    PubMed

    Oloibiri, Violet; Ufomba, Innocent; Chys, Michael; Audenaert, Wim; Demeestere, Kristof; Van Hulle, Stijn W H

    2015-01-01

    A major concern for landfilling facilities is the treatment of their leachate. To optimize organic matter removal from this leachate, the combination of two or more techniques is preferred in order to meet stringent effluent standards. In our study, coagulation-flocculation and ozonation are compared as pre- treatment steps for stabilized landfill leachate prior to granular activated carbon (GAC) adsorption. The efficiency of the pre treatment techniques is evaluated using COD and UVA254 measurements. For coagulation- flocculation, different chemicals are compared and optimal dosages are determined. After this, iron (III) chloride is selected for subsequent adsorption studies due to its high percentage of COD and UVA254 removal and good sludge settle-ability. Our finding show that ozonation as a single treatment is effective in reducing COD in landfill leachate by 66% compared to coagulation flocculation (33%). Meanwhile, coagulation performs better in UVA254 reduction than ozonation. Subsequent GAC adsorption of ozonated effluent, coagulated effluent and untreated leachate resulted in 77%, 53% and 8% total COD removal respectively (after 6 bed volumes). The effect of the pre-treatment techniques on GAC adsorption properties is evaluated experimentally and mathematically using Thomas and Yoon-Nelson models. Mathematical modelling of the experimental GAC adsorption data shows that ozonation increases the adsorption capacity and break through time with a factor of 2.5 compared to coagulation-flocculation.

  11. Cation-induced coagulation of aquatic plant-derived dissolved organic matter: Investigation by EEM-PARAFAC and FT-IR spectroscopy

    USDA-ARS?s Scientific Manuscript database

    Interaction and coagulation of plant-derived dissolved organic matter (DOM) by metal cations are important biogeochemical processes of organic matter in lake systems. Thus, coagulation and fractionation of plant-derived DOM by di- and tri-valent Ca, Al, and Fe ions were investigated. Metal ion-induc...

  12. Complement Activation Alters Platelet Function

    DTIC Science & Technology

    2015-12-01

    haemostatic and coagulation properties of platelets. 15. SUBJECT TERMS Platelets, Complement, Trauma, Tissue Damage 16. SECURITY CLASSIFICATION... coagulation , there is mounting evidence that they may also be important in the development and progression of inflammatory processes (Coppinger et al...receptor-ligand interactions and/or through exposure to cytokines including IL-6, other acute-phase reactants, and pro- coagulant factors such as thrombin

  13. An advanced pretreatment strategy involving hydrodynamic and acoustic cavitation along with alum coagulation for the mineralization and biodegradability enhancement of tannery waste effluent.

    PubMed

    Saxena, Shivendu; Rajoriya, Sunil; Saharan, Virendra Kumar; George, Suja

    2018-06-01

    In the present study, coagulation followed by cavitation was studied as a pretreatment tool for tannery waste effluent (TWE) with the aim of reducing its COD, TOC, TSS etc. and enhancing its biodegradability to make it suitable for anaerobic digestion. Initially, coagulation was applied to TWE using alum as a coagulant. The residual pH of treated effluent was found to be around pH of 4.5 where maximum COD and TSS reduction was achieved. In order to enhance the efficiency of pretreatment process, coagulated tannery waste effluent (CTWE) was further subjected to hydrodynamic cavitation (HC) and ultrasonication (US). In case of HC, effect of process parameters such as inlet pressure and dilution on the treatment of CTWE was initially investigated. Lower operating pressure (5 bar) was more favorable for the treatment of CTWE using HC in order to enhance the biodegradability index (BI) from 0.14 to 0.57 in 120 min. The CTWE samples when subjected to 50% dilution, HC pretreatment exhibited higher percentage and quantum reduction in TOC and COD. On the other hand, pretreatment of TWE using coagulation followed by US demonstrated that BI of effluent was enhanced from 0.10 to 0.41 in 150 min. Energy efficiency evaluation for all processes at their optimized conditions was done based on the actual amount of COD reduced per unit energy delivered to the system. Coagulation followed by HC for the pretreatment of TWE was found to be six times more energy efficient as compared to coagulation followed by US. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Polymorphisms of the factor VII gene associated with the low activities of vitamin K-dependent coagulation factors in one-month-old infants.

    PubMed

    Ito, Koichi; Goto, Kenji; Sugiura, Tokio; Muramatsu, Kanji; Ando, Toshihiro; Maniwa, Hiroko; Yokoyama, Takao; Sugiyama, Kohachiro; Togari, Hajime

    2007-01-01

    Despite administration of vitamin K (VK), some infants show lower activity of VK-dependent coagulation factors and they could develop intracranial hemorrhage. For preventing VK deficiency bleeding (VKDB) in infants, oral administration of VK and a screening test for VK deficiency are carried out in Japan. For the screening, the total activity of VK-dependent coagulation factors is measured using a commercial product, Normotest. This study was undertaken to clarify the importance of the following genetic and environmental factors on the coagulation status in one-month-old infants: two polymorphisms in the factor VII gene, -323P0/10 (a 10-bp insertion in the promoter region at position -323) and R353Q (the replacement of arginine [R] with glutamine [Q] at residue 353) and sex, age, gestational age, birth weight, and feeding regimen. Two hundred Japanese infants (34.6 +/- 4.0 days old) were screened for VK-dependent coagulation activity with Normotest and were genotyped for the two polymorphisms. Among the subjects screened, 18 infants (9%) carried the P10 allele and 26 (13%) carried the R353Q allele. Multiple regression analysis showed that the 10-bp inserted (P10) allele or the Q allele was associated with the lower coagulation activities. The coagulation activities for the R/Q genotype were significantly lower than those for the R/R genotype and those for the P0/P10 genotype were significantly lower than those for the P0/P0 genotype. Therefore, infants who carry the P10 allele or the Q allele show lower activity of VK-dependent coagulation factors. These infants may have a higher risk of VKDB manifestation.

  15. Influence of NaCl Concentrations on Coagulation, Temperature, and Electrical Conductivity Using a Perfusion Radiofrequency Ablation System: An Ex Vivo Experimental Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aube, Christophe, E-mail: ChAube@chu-angers.fr; Schmidt, Diethard; Brieger, Jens

    2007-02-15

    Purpose. To determine, by means of an ex vivo study, the effect of different NaCl concentrations on the extent of coagulation obtained during radiofrequency (RF) ablation performed using a digitally controlled perfusion device. Method. Twenty-eight RF ablations were performed with 40 W for 10 min using continuous NaCl infusion in fresh excised bovine liver. For perfusion, NaCl concentrations ranging from 0 (demineralized water) to 25% were used. Temperature, the amount of energy, and the dimensions of thermal-induced white coagulation were assessed for each ablation. These parameters were compared using the nonparametric Mann-Whitney test. Correlations were calculated according to the Spearmanmore » test. Results. RF ablation performed with 0.9% to 25% concentrations of NaCl produced a mean volume of coagulation of 30.7 {+-} 3.8 cm{sup 3}, with a mean short-axis diameter of 3.6 {+-} 0.2 cm. The mean amount of energy was 21,895 {+-} 1,674 W and the mean temperature was 85.4 {+-} 12.8 deg. C. Volume of coagulation, short-axis diameter, and amount of energy did not differ significantly among NaCl concentrations (p > 0.5). A correlation was found between the NaCl concentration and the short-axis diameter of coagulation (r = 0.64) and between the NaCl concentration and the mean temperature (r = 0.67), but not between the NaCl concentration and volume of coagulation. Conclusion. In an ex vivo model, continuous perfusion with high NaCl concentrations does not significantly improve the volume of thermal-induced coagulation. This may be because the use of a low-power generator cannot sufficiently exploit the potential advantage of better tissue conductivity provided by NaCl perfusion.« less

  16. [Coagulation factor VII levels in uremic patients and theirs influence factors].

    PubMed

    Fang, Jun; Xia, Ling-Hui; Wei, Wen-Ning; Song, Shan-Jun

    2004-12-01

    This study was aimed to investigate coagulation factor VII level in uremic patients with chronic renal failure and to explore theirs influence factors. The plasma levels of coagulation factor VII were detected in 30 uremic patients with chronic renal failure before and after hemodialysis for 1 month, the factor VII activity (FVII:C) was determined by one-stage coagulation method, while activated factor VII (FVIIa) was measured by one-stage coagulation method using recombinant soluble tissue factor, and factor VII antigen was detected by ELISA. The results showed that: (1) The FVIIa, FVII:C and FVIIAg levels in chronic uremic patients before hemodialysis were 4.00 +/- 0.86 microg/L, (148.5 +/- 40.4)% and (99.8 +/- 21.1)% respectively, which were significantly increased, as compared with healthy controls [2.77 +/- 1.02 microg/L, (113.1 +/- 33.0)% and (73.7 +/- 18.3)% respectively, P < 0.05]. (2) After hemodialysis the FVIIa, FVII:C and FVIIAg levels in uremic patients significantly enhanced to 5.56 +/- 1.45 microg/L, (200.8 +/- 68.7)% and (124.1 +/- 19.3)% respectively (P < 0.05). (3) The abnormal increase of coagulation factor VII was positively correlated with levels of blood uria nitrogen and serum creatinine before hemodialysis but not after hemodialysis. It is concluded that the enhanced levels of coagulation factor VII in chronic uremic patients suggested abnormal activated state, herperactivity and elevated production of factor VII which correlated with renal functional injury. The abnormality of factor VII in uremia may be aggravated by hemodialysis. Coagulation factor (FVII) may be a risk factor for cardiovascular events in uremic patients who especially had been accepted long-term hemodialysis.

  17. Hi-tech of the prostate: interstitial laser coagulation of benign prostatic hypertrophy

    NASA Astrophysics Data System (ADS)

    Muschter, Rolf; Hofstetter, Alfons G.; Hessel, Stefan F. F.; Keiditsch, Ernst; Rothenberger, Karl-Heinz; Schneede, Peter; Frank, Klaus H.

    1992-06-01

    We report on the new technique of interstitial laser coagulation of the prostate (ILCP) in the treatment of benign prostatic hyperplasia (BPH). Basic experiments by use of a Nd:YAG laser in combination with a newly designed fiber tip homogeneously distributing the laser irradiation have been performed in potato, muscle, liver, and surgically removed human BPH-tissue to determine the volume of coagulation. The coagulation zone surrounding the probe was well defined and homogeneous. The size was dependent on laser power and irradiation time. Carbonization was never present except in darker tissues irradiated with high energy. Volume and time resolved measurements correlated well with the size of coagulation. 10 W and 5 minutes, for example, resulted in a coagulation zone of 17 X 15 mm. Comparable results have been seen in in-vivo experiments in surgically exposed canine prostates. Specimen for macroscopic and microscopic examination were taken immediately after treatment and after 5 and 35 days. The well demarked coagulation necrosis of the early stage resulted in cystic degeneration and fibrosis in the later stages. This was combined with shrinkage and reduction in volume. The urothelium of the urethra, the external sphincter and the rectum showed no damage. Until now, 15 patients suffering from obstructive symptoms due to BPH have been treated with interstitial laser coagulation. The probes were inserted from the perineum into the center of each lateral lobe of the prostate by transrectal ultrasound guidance, while the median lobe was treated by urethroscopic guidance, while the median lobe was treated by urethroscopic control. Dependent on the size of the prostate irradiation, time was 5 to 10 minutes per lobe at a power setting of 5 to 10 W.

  18. Contact Activation of Blood Plasma and Factor XII by Ion-exchange Resins

    PubMed Central

    Yeh, Chyi-Huey Josh; Dimachkie, Ziad O.; Golas, Avantika; Cheng, Alice; Parhi, Purnendu; Vogler, Erwin A.

    2011-01-01

    Sepharose ion-exchange particles bearing strong Lewis acid/base functional groups (sulfopropyl, carboxymethyl, quarternary ammonium, dimethyl aminoethyl, and iminodiacetic acid) exhibiting high plasma protein adsorbent capacities are shown to be more efficient activators of blood factor XII in neat-buffer solution than either hydrophilic clean-glass particles or hydrophobic octyl sepharose particles ( FXII→surfaceactivatorFXIIa; a.k.a autoactivation, where FXII is the zymogen and FXIIa is a procoagulant protease). In sharp contrast to the clean-glass standard of comparison, ion-exchange activators are shown to be inefficient activators of blood plasma coagulation. These contrasting activation properties are proposed to be due to the moderating effect of plasma-protein adsorption on plasma coagulation. Efficient adsorption of blood plasma proteins unrelated to the coagulation cascade impedes FXII contacts with ion-exchange particles immersed in plasma, reducing autoactivation, and causing sluggish plasma coagulation. By contrast, plasma proteins do not adsorb to hydrophilic clean glass and efficient autoactivation leads directly to efficient activation of plasma coagulation. It is also shown that competitive-protein adsorption can displace FXIIa adsorbed to the surface of ion-exchange resins. As a consequence of highly-efficient autoactivation and FXIIa displacement by plasma proteins, ion-exchange particles are slightly more efficient activators of plasma coagulation than hydrophobic octyl sepharose particles that do not bear strong Lewis acid/base surface functionalities but to which plasma proteins adsorb efficiently. Plasma proteins thus play a dual role in moderating contact activation of the plasma coagulation cascade. The principal role is impeding FXII contact with activating surfaces but this same effect can displace FXIIa from an activating surface into solution where the protease can potentiate subsequent steps of the plasma coagulation cascade. PMID:21982294

  19. Economic evaluation of a randomized controlled trial of pharmacist-supervized patient self-testing of warfarin therapy.

    PubMed

    Gallagher, J; Mc Carthy, S; Woods, N; Ryan, F; O' Shea, S; Byrne, S

    2015-02-01

    The increase in numbers of patients requiring oral anti-coagulation testing in outpatient clinics has focused attention on alternative flexible systems of anti-coagulation management. One option is pharmacist led patient self-testing (PST) of international normalised ratio (INR) levels. PST has demonstrated improvements in anti-coagulation control, but its cost-effectiveness is inconclusive. This study reports the first cost-effectiveness evaluation of a randomized controlled trial of an automated direct-to-patient expert system, enabling remote and effective management of patients on oral anti-coagulation therapy. We conducted an economic evaluation alongside a randomised controlled trial investigating a pharmacist led PST method. The primary outcome was to determine the cost effectiveness of PST in comparison with usual care (management in a hospital based anti-coagulation clinic). Long term anti-coagulation patients were recruited to a 6 month cross over study between PST and routine care in an anti-coagulation clinic. Economic evaluation was from the healthcare payer perspective. On a per patient basis over a 6 month period, PST resulted in an incremental cost of €59.08 in comparison with routine care. Patients achieved a significantly higher time in therapeutic range (TTR) during the PST arm in comparison with routine care, (72 ± 19.7% vs. 59 ± 13.5%). Overall cost of managing a patient through pharmacist supervised PST for a 6 month period is €226.45. Additional analysis of strategies from a societal perspective indicated that PST was the dominant strategy. Pharmacist led patient self-testing is a viable method of management. It provides significant increases in anti-coagulation control for a minimal increase in cost. © 2014 John Wiley & Sons Ltd.

  20. Reduction of DOM fractions and their trihalomethane formation potential in surface river water by in-line coagulation with ceramic membrane filtration.

    PubMed

    Rakruam, Pharkphum; Wattanachira, Suraphong

    2014-03-01

    This research was aimed at investigating the reduction of DOM fractions and their trihalomethane formation potential (THMFP) by in-line coagulation with 0.1 μm ceramic membrane filtration. The combination of ceramic membrane filtration with a coagulation process is an alternative technology which can be applied to enhance conventional coagulation processes in the field of water treatment and drinking water production. The Ping River water (high turbidity water) was selected as the raw surface water because it is currently the main raw water source for water supply production in the urban and rural areas of Chiang Mai Province. From the investigation, the results showed that the highest percent reductions of DOC, UV-254, and THMFP (47.6%, 71.0%, and 67.4%, respectively) were achieved from in-line coagulation with ceramic membrane filtration at polyaluminum chloride dosage 40 mg/L. Resin adsorption techniques were employed to characterize the DOM in raw surface water and filtered water. The results showed that the use of a ceramic membrane with in-line coagulation was able to most efficiently reduce the hydrophobic fraction (HPOA) (68.5%), which was then followed by the hydrophilic fraction (HPIA) (49.3%). The greater mass DOC reduction of these two fractions provided the highest THMFP reductions (55.1% and 37.2%, respectively). Furthermore, the in-line coagulation with ceramic membrane filtration was able to reduce the hydrophobic (HPOB) fraction which is characterized by high reactivity toward THM formation. The percent reduction of mass DOC and THMFP of HPOB by in-line coagulation with ceramic membrane filtration was 45.9% and 48.0%, respectively. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  1. Use of Ceramic Membranes in a Membrane Filtration Supported by Coagulation for the Treatment of Dairy Wastewater.

    PubMed

    Zielińska, Magdalena; Galik, Maciej

    2017-01-01

    A membrane filtration system was used to remove organic compounds, suspended solids, colour and turbidity from anaerobically treated dairy wastewater. Direct microfiltration (MF), ultrafiltration (UF), MF-UF and a combination of UF with coagulation using two conventional coagulants were investigated. The installation with ceramic membranes was operated at a pressure of 0.15 MPa (MF) and 0.3 MPa (UF). COD removal was 89 ± 2% in MF, 95 ± 1% in UF and 99% in MF-UF. Apart from size exclusion, removal was also the result of adsorption of organics on the membrane; 3-18% of COD removal was attributed to adsorption. In all these membrane systems, colour removal was 96-98%. Coagulation removed 63-72% of COD at all coagulant doses. In combination with UF, 96-97% of COD was removed. The use of coagulants was ineffective for colour removal; further treatment by UF resulted in above 98% removal. Because of complete rejection of suspended solids, turbidity removal exceeded 99% under all conditions. The use of increased coagulant doses did not have an effect on total efficiency of pollutant removal and on the permeate flux. Coagulation pre-treatment enhanced the performance of filtration only by lengthening the filtration cycle by about 12% as compared to direct UF. Not only was pollutant removal highest in MF-UF, but also the average permeate flux was about 80% higher in this two-stage system than in direct UF. This study shows that the most effective strategy to mitigate membrane fouling is the use of MF as a pre-treatment preceding UF.

  2. Influence of fat replacement by inulin on rheological properties, kinetics of rennet milk coagulation, and syneresis of milk gels.

    PubMed

    Arango, O; Trujillo, A J; Castillo, M

    2013-04-01

    The objective of this study was to evaluate the effect of inulin as a fat replacer on the rheological properties, coagulation kinetics, and syneresis of milk gels. A randomized factorial design, replicated 3 times, with 3 inulin concentrations (0, 3, and 6%), 2 levels of fat (<0.2 and 1.5%), and 3 coagulation temperatures (27, 32, and 37°C) was used. The coagulation process was monitored using near-infrared spectrometry, small amplitude oscillatory rheometry, and visual coagulation indexes. The syneresis was evaluated by volumetric methods. Inulin addition increased the rates of aggregation and curd firming reactions in the casein gels. The observed effect, which was more evident on the aggregation reaction, depended on the concentration of inulin and the coagulation temperature. Addition of 6% inulin reduced the clotting time by approximately 26% and the time at which the gel reached a storage modulus equal to 30 Pa by approximately 36%. The optical parameter R'max, defined as the maximum value of change in light backscatter profile/change in time (where R' = dR/dt), was used to calculate an approximation of the temperature coefficients (Q10) for milk coagulation. Increasing fat concentration induced a consistent increase in all the optical, rheological, and visual parameters studied, although the observed trend was not statistically significant. The addition of inulin at a level of 6% produced a reduction in syneresis and increased the curd yield by approximately 30%. It was concluded that the addition of inulin affects the kinetics of milk coagulation and the cutting time and, therefore, the use of inline sensors such as near-infrared spectrometry may be necessary for optimal process control. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Coagulation Imbalance and Neurocognitive Functioning in Older HIV+ Adults on Suppressive Antiretroviral Therapy

    PubMed Central

    Montoya, Jessica l.; Iudicello, Jennifer; Oppenheim, Hannah A.; Fazeli, Pariya l.; Potter, Michael; MA, Qing; Mills, Paul J.; Ellis, Ronald J.; Grant, Igor; Letendre, Scott l.; Moore, David J.

    2017-01-01

    Objectives To compare plasma biomarkers of coagulation between HIV-infected individuals and HIV-uninfected controls and to assess the impact of disturbances in coagulation on neurocognitive functioning in HIV. Design Cross-sectional study of 66 antiretroviral therapy-treated virally suppressed HIV-infected and 34 HIV-uninfected older (≥50 years of age) adults. Methods Participants completed standardized neurobehavioral and neuromedical assessments. Neurocognitive functioning was evaluated using a well-validated comprehensive neuropsychological battery. Plasma biomarkers associated with procoagulation (fibrinogen, p-selectin, tissue factor, and von Willebrand factor), anticoagulation (antithrombin, protein C, and thrombomodulin), fibrinolysis (d-dimer, plasminogen activator inhibitor-1, and plasminogen) were collected. Multivariable linear regression was used to test the interaction of HIV and coagulation on neurocognitive functioning. Results Most participants were male (78.0%) and non-Hispanic white (73.0%) with a mean age of 57.8 years. Among HIV-infected participants, mean estimated duration of HIV infection was 19.4 years and median current CD4+ cell count was 654 cells/mm3. Levels of soluble biomarkers of procoagulation, anticoagulation, and fibrinolysis were comparable between the HIV serostatus groups. Coagulation and HIV had an interacting effect on neurocognitive functioning, such that greater coagulation imbalance was associated with poorer neurocognitive functioning among the HIV-infected participants. The moderating effect of coagulation on neurocognition was driven by procoagulant but not anticoagulant or fibrinolytic biomarkers. Conclusions Elevated levels of procoagulants may exert a particularly detrimental effect on neurocognitive functioning among older HIV-infected persons. A better understanding of the specific role of coagulation in the etiology of HIV-associated neurocognitive disorders may lead to treatments aimed at reducing coagulopathy, thereby improving neurocognitive outcomes. PMID:28099190

  4. Coagulation imbalance and neurocognitive functioning in older HIV-positive adults on suppressive antiretroviral therapy.

    PubMed

    Montoya, Jessica L; Iudicello, Jennifer; Oppenheim, Hannah A; Fazeli, Pariya L; Potter, Michael; Ma, Qing; Mills, Paul J; Ellis, Ronald J; Grant, Igor; Letendre, Scott L; Moore, David J

    2017-03-27

    The aim of this study was to compare plasma biomarkers of coagulation between HIV-infected individuals and HIV-uninfected controls and to assess the impact of disturbances in coagulation on neurocognitive functioning in HIV. A cross-sectional study of 66 antiretroviral therapy treated, virally suppressed, HIV-infected and 34 HIV-uninfected older (≥50 years of age) adults. Participants completed standardized neurobehavioral and neuromedical assessments. Neurocognitive functioning was evaluated using a well validated comprehensive neuropsychological battery. Plasma biomarkers associated with procoagulation (fibrinogen, p-selectin, tissue factor and von Willebrand factor), anticoagulation (antithrombin, protein C and thrombomodulin), fibrinolysis (d-dimer, plasminogen activator inhibitor-1 and plasminogen) were collected. Multivariable linear regression was used to test the interaction of HIV and coagulation on neurocognitive functioning. Most participants were male (78.0%) and non-Hispanic white (73.0%) with a mean age of 57.8 years. Among HIV-infected participants, mean estimated duration of HIV infection was 19.4 years and median current CD4 cell count was 654 cells/μl. Levels of soluble biomarkers of procoagulation, anticoagulation and fibrinolysis were comparable between the HIV serostatus groups. Coagulation and HIV had an interacting effect on neurocognitive functioning, such that greater coagulation imbalance was associated with poorer neurocognitive functioning among the HIV-infected participants. The moderating effect of coagulation on neurocognition was driven by procoagulant but not anticoagulant or fibrinolytic biomarkers. Elevated levels of procoagulants may exert a particularly detrimental effect on neurocognitive functioning among older HIV-infected persons. A better understanding of the specific role of coagulation in the cause of HIV-associated neurocognitive disorders may lead to treatments aimed at reducing coagulopathy, thereby improving neurocognitive outcomes.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than thosemore » without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.« less

  6. Interpretation of coagulation test results using a web-based reporting system.

    PubMed

    Quesada, Andres E; Jabcuga, Christine E; Nguyen, Alex; Wahed, Amer; Nedelcu, Elena; Nguyen, Andy N D

    2014-01-01

    Web-based synoptic reporting has been successfully integrated into diverse fields of pathology, improving efficiency and reducing typographic errors. Coagulation is a challenging field for practicing pathologists and pathologists-in-training alike. To develop a Web-based program that can expedite the generation of a individualized interpretive report for a variety of coagulation tests. We developed a Web-based synoptic reporting system composed of 119 coagulation report templates and 38 thromboelastography (TEG) report templates covering a wide range of findings. Our institution implemented this reporting system in July 2011; it is currently used by pathology residents and attending pathologists. Feedback from the users of these reports have been overwhelmingly positive. Surveys note the time saved and reduced errors. Our easily accessible, user-friendly, Web-based synoptic reporting system for coagulation is a valuable asset to our laboratory services. Copyright© by the American Society for Clinical Pathology (ASCP).

  7. Dataset on the spent filter backwash water treatment by sedimentation, coagulation and ultra filtration.

    PubMed

    Mahdavi, Mokhtar; Ebrahimi, Afshin; Azarpira, Hossein; Tashauoei, Hamid Reza; Mahvi, Amir Hossein

    2017-12-01

    During operation of most water treatment plants, spent filter backwash water (SFBW) is generated, which accounts about 2-10% of the total plant production. By increasing world population and water shortage in many countries, SFBW can be used as a permanent water source until the water treatment plant is working. This data article reports the practical method being used for water reuse from SFBW through different method including pre-sedimentation, coagulation and flocculation, second clarification, ultra filtration (UF) and returned settled SFBW to the beginning of water treatment plant (WTP). Also, two coagulants of polyaluminum ferric chloride (PAFCl) and ferric chloride (FeCl 3 ) were investigated with respect to their performance on treated SFBW quality. Samples were collected from Isfahan's WTP in Iran during spring and summer season. The acquired data indicated that drinkable water can be produced form SFBW by applying hybrid coagulation-UF process (especially when PAFCl used as coagulant).

  8. Neonatal Plasma Transfusion: An Evidence-Based Review.

    PubMed

    Keir, Amy K; Stanworth, Simon J

    2016-10-01

    Several clinical scenarios for plasma transfusion are repeatedly identified in audits, including treatment of bleeding in association with laboratory evidence of coagulopathy, correction of disseminated intravascular coagulation, prevention of intraventricular hemorrhage, management of critically ill neonates (eg, during sepsis or as a volume expander), or correction of markers of prolonged coagulation in the absence of bleeding. The findings of at least one national audit of transfusion practice indicated that almost half of plasma transfusions are given to neonates with abnormal coagulation values with no evidence of active bleeding, despite the limited evidence base to support the effectiveness of this practice. Plasma transfusions to neonates should be considered in the clinical context of bleeding (eg, vitamin K dependent), disseminated intravascular coagulation, and very rare inherited deficiencies of coagulation factors. There seems to be no role for prophylactic plasma to prevent intraventricular hemorrhage or for use as a volume expander. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Pretreatment of palm oil mill effluent (POME) using Moringa oleifera seeds as natural coagulant.

    PubMed

    Bhatia, Subhash; Othman, Zalina; Ahmad, Abdul Latif

    2007-06-25

    Moringa oleifera seeds, an environmental friendly and natural coagulant are reported for the pretreatment of palm oil mill effluent (POME). In coagulation-flocculation process, the M. oleifera seeds after oil extraction (MOAE) are an effective coagulant with the removal of 95% suspended solids and 52.2% reduction in the chemical oxygen demand (COD). The combination of MOAE with flocculant (NALCO 7751), the suspended solids removal increased to 99.3% and COD reduction was 52.5%. The coagulation-flocculation process at the temperature of 30 degrees C resulted in better suspended solids removal and COD reduction compared to the temperature of 40, 55 and 70 degrees C. The MOAE combined with flocculant (NALCO 7751) reduced the sludge volume index (SVI) to 210mL/g with higher recovery of dry mass of sludge (87.25%) and water (50.3%).

  10. Acute Coagulopathy of Trauma in the Rat

    DTIC Science & Technology

    2013-01-01

    coagulation and include prothrombin complex con- centrate, recombinant activated FVII , tranexamic acid, and fibrinogen (13, 14). The degree of coagulopathy...extrinsic pathway using tissue factor to initiate coagulation as would be expected following tissue injury. Cytochalasin D (inhibit platelet function in...chalasin D. ! Angle was elevated, and clotting time was shortened, suggesting that coagulation factors were activated and adequate to support thrombin

  11. On coagulation mechanisms of charged nanoparticles produced by combustion of hydrocarbon and metallized fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savel'ev, A. M.; Starik, A. M.

    2009-02-15

    The contributions of van der Waals, Coulomb, and polarization interactions between nanometersized particles to the particle coagulation rate in both free-molecular and continuum regimes are analyzed for particle charges of various magnitudes and signs. Analytical expressions are obtained for the coagulation rate constant between particles whose interaction in the free-molecular regime is described by a singular potential. It is shown that van der Waals and polarization forces significantly increase the coagulation rate between a neutral and a charged particle (by a factor of up to 10) and can even suppress the Coulomb repulsion between like-charged particles of widely different sizes.

  12. Coagulation tests show significant differences in patients with breast cancer.

    PubMed

    Tas, Faruk; Kilic, Leyla; Duranyildiz, Derya

    2014-06-01

    Activated coagulation and fibrinolytic system in cancer patients is associated with tumor stroma formation and metastasis in different cancer types. The aim of this study is to explore the correlation of blood coagulation assays for various clinicopathologic factors in breast cancer patients. A total of 123 female breast cancer patients were enrolled into the study. All the patients were treatment naïve. Pretreatment blood coagulation tests including PT, APTT, PTA, INR, D-dimer, fibrinogen levels, and platelet counts were evaluated. Median age of diagnosis was 51 years old (range 26-82). Twenty-two percent of the group consisted of metastatic breast cancer patients. The plasma level of all coagulation tests revealed statistically significant difference between patient and control group except for PT (p<0.001 for all variables except for PT; p=0.08). Elderly age (>50 years) was associated with higher D-dimer levels (p=0.003). Metastatic patients exhibited significantly higher D-dimer values when compared with early breast cancer patients (p=0.049). Advanced tumor stage (T3 and T4) was associated with higher INR (p=0.05) and lower PTA (p=0.025). In conclusion, coagulation tests show significant differences in patients with breast cancer.

  13. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.

    PubMed

    Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan

    2017-05-15

    Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1μl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R 2 =0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    PubMed

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  15. Isolation and characterization of coagulant extracted from Moringa oleifera seed by salt solution.

    PubMed

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-02-01

    It is known that M. oleifera contains a natural coagulant in the seeds. In our previous research, the method using salt water to extract the active coagulation component from M. oleifera seeds was developed and compared with the conventional method using water. In this research, the active coagulation component was purified from a NaCl solution crude extract of Moringa oleifera seeds. The active component was isolated and purified from the crude extract through a sequence of steps that included salting-out by dialysis, removal of lipids and carbohydrates by homogenization with acetone, and anion exchange. Specific coagulation activity of the active material increased up to 34 times more than the crude extract after the ion exchange. The active component was not the same as that of water extract. The molecular weight was about 3000 Da. The Lowry method and the phenol-sulfuric acid method indicated that the active component was neither protein nor polysaccharide. The optimum pH of the purified active component for coagulation of turbidity was pH 8 and above. Different from the conventional water extracts, the active component can be used for waters with low turbidity without increase in the dissolved organic carbon concentration.

  16. Principles of dielectric blood coagulometry as a comprehensive coagulation test.

    PubMed

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Nagasawa, Masayuki

    2015-10-06

    Dielectric blood coagulometry (DBCM) is intended to support hemostasis management by providing comprehensive information on blood coagulation from automated, time-dependent measurements of whole blood dielectric spectra. We discuss the relationship between the series of blood coagulation reactions, especially the aggregation and deformation of erythrocytes, and the dielectric response with the help of clot structure electron microscope observations. Dielectric response to the spontaneous coagulation after recalcification presented three distinct phases that correspond to (P1) rouleau formation before the onset of clotting, (P2) erythrocyte aggregation and reconstitution of aggregates accompanying early fibrin formation, and (P3) erythrocyte shape transformation and/or structure changes within aggregates after the stable fibrin network is formed and platelet contraction occurs. Disappearance of the second phase was observed upon addition of tissue factor and ellagic acid for activation of extrinsic and intrinsic pathways, respectively, which is attributable to accelerated thrombin generation. A series of control experiments revealed that the amplitude and/or quickness of dielectric response reflect platelet function, fibrin polymerization, fibrinolysis activity, and heparin activity. Therefore, DBCM sensitively measures blood coagulation via erythrocytes aggregation and shape changes and their impact on the dielectric permittivity, making possible the development of the battery of assays needed for comprehensive coagulation testing.

  17. Mercury, monomethyl mercury, and dissolved organic carbon concentrations in surface water entering and exiting constructed wetlands treated with metal-based coagulants, Twitchell Island, California

    USGS Publications Warehouse

    Stumpner, Elizabeth B.; Kraus, Tamara E.C.; Fleck, Jacob A.; Hansen, Angela M.; Bachand, Sandra M.; Horwath, William R.; DeWild, John F.; Krabbenhoft, David P.; Bachand, Philip A.M.

    2015-09-02

    Following coagulation, but prior to passage through the wetland cells, coagulation treatments transferred dissolved mercury and carbon to the particulate fraction relative to untreated source water: at the wetland cell inlets, the coagulation treatments decreased concentrations of filtered total mercury by 59–76 percent, filtered monomethyl mercury by 40–70 percent, and dissolved organic carbon by 65–86 percent. Passage through the wetland cells decreased the particulate fraction of mercury in wetland cells that received coagulant-treated water. Changes in total mercury, monomethyl mercury, and dissolved organic carbon concentrations resulting from wetland passage varied both by treatment and season. Despite increased monomethyl mercury in the filtered fraction during wetland passage between March and August, the coagulation-wetland systems generally decreased total mercury (filtered plus particulate) and monomethyl mercury (filtered plus particulate) concentrations relative to source water. Coagulation—either alone or in association with constructed wetlands—could be an effective way to decrease concentrations of mercury and dissolved organic carbon in surface water as well as the bioavailability of mercury in the Sacramento–San Joaquin Delta.

  18. Establishment of reference values for various coagulation tests in healthy Florida manatees (Trichechus manatus latirostris) and evaluation of coagulation in debilitated manatees during rehabilitation.

    PubMed

    Gerlach, Trevor J; Bandt, Carsten; Conner, Bobbi; Ball, Ray L

    2015-11-01

    To establish reference ranges for coagulation parameters in healthy Florida manatees (Trichechus manatus latirostris) and compare results with those for debilitated manatees undergoing treatment at a rehabilitation facility. Prospective study. 29 healthy manatees and 45 debilitated manatees with various diseases. Manatees considered healthy on the basis of results of physical examination, CBC, and serum biochemical analysis underwent coagulation testing including measurement of prothrombin time, partial thromboplastin time, D-dimer concentration, platelet count, and fibrinogen concentration to establish reference ranges. For comparison, a group of manatees undergoing rehabilitation was also tested, and the results were compared. Thromboelastography was also performed on some animals. Values for D-dimer concentration were significantly higher in debilitated versus healthy animals. There was no significant difference for prothrombin time, partial thromboplastin time, platelet count, or fibrinogen concentration between groups. Thromboelastography was performed on 8 healthy animals. Reference ranges were established for various tests of coagulation that may assist clinicians during the initial evaluation and rehabilitation of Florida manatees. Future research to evaluate the effect of specific disease processes on the coagulation cascade is recommended.

  19. Coagulation removal of humic acid-stabilized carbon nanotubes from water by PACl: influences of hydraulic condition and water chemistry.

    PubMed

    Ma, Si; Liu, Changli; Yang, Kun; Lin, Daohui

    2012-11-15

    Discharged carbon nanotubes (CNTs) can adsorb the widely-distributed humic acid (HA) in aquatic environments and thus be stabilized. HA-stabilized CNTs can find their way into and challenge the potable water treatment system. This study investigated the efficiency of coagulation and sedimentation techniques in the removal of the HA-stabilized multi-walled carbon nanotubes (MWCNTs) using polyaluminum chloride (PACl) as a coagulant, with a focus on the effects of hydraulic conditions and water chemistry. Stirring speeds in the mixing and reacting stages were gradually changed to examine the effect of the hydraulic conditions on the removal rate. The stirring speed in the reacting stage affected floc formation and thereby had a greater impact on the removal rate than the stirring speed in the mixing stage. Water chemistry factors such as pH and ionic strength had a significant effect on the stability of MWCNT suspension and the removal efficiency. Low pH (4-7) was favorable for saving the coagulant and maintaining high removal efficiency. High ionic strength facilitated the destabilization of the HA-stabilized MWCNTs and thereby lowered the required PACl dosage for the coagulation. However, excessively high ionic strength (higher than the critical coagulation concentration) decreased the maximum removal rate, probably by inhibiting ionic activity of PACl hydrolyzate in water. These results are expected to shed light on the potential improvement of coagulation removal of aqueous stabilized MWCNTs in water treatment systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Application of Fe(II)/peroxymonosulfate for improving ultrafiltration membrane performance in surface water treatment: Comparison with coagulation and ozonation.

    PubMed

    Cheng, Xiaoxiang; Liang, Heng; Ding, An; Zhu, Xuewu; Tang, Xiaobin; Gan, Zhendong; Xing, Jiajian; Wu, Daoji; Li, Guibai

    2017-11-01

    Coagulation and ozonation have been widely used as pretreatments for ultrafiltration (UF) membrane in drinking water treatment. While beneficial, coagulation or ozonation alone is unable to both efficiently control membrane fouling and product water quality in many cases. Thus, in this study an emerging alternative of ferrous iron/peroxymonosulfate (Fe(II)/PMS), which can act as both an oxidant and a coagulant was employed prior to UF for treatment of natural surface water, and compared with conventional coagulation and ozonation. The results showed that the Fe(II)/PMS-UF system exhibited the best performance for dissolved organic carbon removal, likely due to the dual functions of coagulation and oxidation in the single process. The fluorescent and UV-absorbing organic components were more susceptible to ozonation than Fe(II)/PMS treatment. Fe(II)/PMS and ozonation pretreatments significantly increased the removal efficiency of atrazine, p-chloronitrobenzene and sulfamethazine by 12-76% and 50-94%, respectively, whereas coagulation exerted a minor influence. The Fe(II)/PMS pretreatment also showed the best performance for the reduction of both reversible and irreversible membrane fouling, and the performance was hardly affected by membrane pore size and surface hydrophobicity. In addition, the characterization of hydraulic irreversible organic foulants confirmed its effectiveness. These results demonstrate the potential advantages of applying Fe(II)/PMS as a pretreatment for UF to simultaneously control membrane fouling and improve the permeate quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Algal removal from cyanobacteria-rich waters by preoxidation-assisted coagulation-flotation: Effect of algogenic organic matter release on algal removal and trihalomethane formation.

    PubMed

    Lin, Jr-Lin; Hua, Lap-Cuong; Hung, Shih Kai; Huang, Chihpin

    2018-01-01

    The cyanobacteria-bloom in raw waters frequently causes an unpredictable chemical dosing of preoxidation and coagulation for an effective removal of algal cells in water treatment plants. This study investigated the effects of preoxidation with NaOCl and ClO 2 on the coagulation-flotation effectiveness in the removal of two commonly blooming cyanobacteria species, Microcystis aeruginosa (MA) and Cylindrospermopsis raciborskii (CR), and their corresponding trihalomethane (THM) formation potential. The results showed that dual dosing with NaOCl plus ClO 2 was more effective in enhancing the deformation of cyanobacterial cells compared to single dosing with NaOCl, especially for CR-rich water. Both preoxidation approaches for CR-rich water effectively reduced the CR cell count with less remained dissolved organic carbon (DOC), which benefited subsequent coagulation-flotation. However, preoxidation led to an adverse release of algogenic organic matter (AOM) in the case of MA-rich water. The release of AOM resulted in a poor removal in MA cells and a large amount of THM formation after oxidation-assisted coagulation-flotation process. The reduction in THM formation potential of CR-rich waters is responsible for effective algae and DOC removal by alum coagulation. It is concluded that the species-specific characteristic of cyanobacteria and their AOM released during chlorination significantly influences the performance of coagulation-flotation for AOM removal and corresponding THM formation. Copyright © 2017. Published by Elsevier B.V.

  2. Comparison of infrared coagulation and rubber band ligation for first and second degree haemorrhoids: a randomised prospective clinical trial.

    PubMed Central

    Templeton, J L; Spence, R A; Kennedy, T L; Parks, T G; Mackenzie, G; Hanna, W A

    1983-01-01

    One hundred and thirty seven previously untreated out-patients with first and second degree haemorrhoids were allocated at random to treatment by infrared coagulation (n=66) or rubber band ligation (n=71). Complete follow up was obtained in 122 patients (60 who had undergone infrared coagulation (group 1), and 62 rubber band ligation (group 2)) at periods from three months to one year after completion of treatment. Infrared coagulation produced a satisfactory outcome in 51 patients (85%): 34 were rendered asymptomatic and 17 improved. Rubber band ligation produced a satisfactory outcome in 57 patients (92%): 33 were rendered asymptomatic and 24 improved. Both methods were equally effective in first and second degree haemorrhoids. The incidence of side effects, particularly discomfort, during and after treatment was significantly higher in those treated by rubber band ligation (p less than 0.001). This appeared to be an appreciable deterrent to future patient compliance. The number of patients losing more than 24 hours from work was higher after rubber band ligation than after infrared coagulation. The number of treatments necessary to cure symptoms did not differ significantly between the two methods. Infrared coagulation was significantly faster than rubber band ligation (p less than 0.001). Infrared coagulation is a simple, fast, and effective outpatient method for the treatment of first and second degree haemorrhoids with fewer troublesome side effects and higher patient acceptability than rubber band ligation. PMID:6404471

  3. [Effects on phenol removal in the process of enhanced coagulation by manganese dioxide formed in situ].

    PubMed

    Zhang, Li-Zhu; Chen, Xiao-Dong; Ma, Jun; Yu, Min; Li, Xin

    2011-10-01

    Phenol was selected as a model compound. Factors, such as Ca2+, tannic acid, dose of kaolinite, dose of manganese dioxide formed in situ and pH, were invested on phenol removal in the process of enhanced coagulation by manganese dioxide formed in situ. Results showed that the addition of Ca2+ is beneficial for phenol removal. In the range of Ca2+ varied from 0 to 1.0 mmol x L(-1), the efficiency of phenol removal was enhanced more than 10%. Tannic acid can enhance phenol removal significantly when they are coexisted in water. As tannic acid was added to 10 mg x L(-1), phenol removal can be increased about 30% and 50% in the process of coagulation by AlCl3 and enhanced coagulation by manganese dioxide formed in situ, respectively. The dose of coagulant can be reduced in the process of enhanced coagulation with the addition of manganese dioxide formed in situ. The point of 1 mg x L(-1) manganese dioxide formed in situ linked with 30 mg x L(-1) AlCl3 can have the same phenol removal efficiency as the addition of 50 mg x L(-1) AlCl3. In the range of pH varied from 5 to 9, phenol can be removed with the high efficiency in the process of enhanced coagulation by manganese dioxide formed in situ. While under the strong acid condition and strong basic condition, phenol has lower removal efficiency.

  4. Untangling the complexity of blood coagulation network: use of computational modelling in pharmacology and diagnostics.

    PubMed

    Shibeko, Alexey M; Panteleev, Mikhail A

    2016-05-01

    Blood coagulation is a complex biochemical network that plays critical roles in haemostasis (a physiological process that stops bleeding on injury) and thrombosis (pathological vessel occlusion). Both up- and down-regulation of coagulation remain a major challenge for modern medicine, with the ultimate goal to correct haemostasis without causing thrombosis and vice versa. Mathematical/computational modelling is potentially an important tool for understanding blood coagulation disorders and their treatment. It can save a huge amount of time and resources, and provide a valuable alternative or supplement when clinical studies are limited, or not ethical, or technically impossible. This article reviews contemporary state of the art in the modelling of blood coagulation for practical purposes: to reveal the molecular basis of a disease, to understand mechanisms of drug action, to predict pharmacodynamics and drug-drug interactions, to suggest potential drug targets or to improve quality of diagnostics. Different model types and designs used for this are discussed. Functional mechanisms of procoagulant bypassing agents and investigations of coagulation inhibitors were the two particularly popular applications of computational modelling that gave non-trivial results. Yet, like any other tool, modelling has its limitations, mainly determined by insufficient knowledge of the system, uncertainty and unreliability of complex models. We show how to some extent this can be overcome and discuss what can be expected from the mathematical modelling of coagulation in not-so-far future. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  5. Coagulation and ablation patterns of high-intensity focused ultrasound on a tissue-mimicking phantom and cadaveric skin.

    PubMed

    Kim, Hee-Jin; Kim, Han Gu; Zheng, Zhenlong; Park, Hyoun Jun; Yoon, Jeung Hyun; Oh, Wook; Lee, Cheol Woo; Cho, Sung Bin

    2015-12-01

    High-intensity focused ultrasound (HIFU) can be applied noninvasively to create focused zones of tissue coagulation on various skin layers. We performed a comparative study of HIFU, evaluating patterns of focused tissue coagulation and ablation upon application thereof. A tissue-mimicking (TM) phantom was prepared with bovine serum albumin and polyacrylamide hydrogel to evaluate the geometric patterns of HIFU-induced thermal injury zones (TIZs) for five different HIFU devices. Additionally, for each device, we investigated histologic patterns of HIFU-induced coagulation and ablation in serial sections of cadaveric skin of the face and neck. All HIFU devices generated remarkable TIZs in the TM phantom, with different geometric values of coagulation for each device. Most of the TIZs seemed to be separated into two or more tiny parts. In cadaveric skin, characteristic patterns of HIFU-induced ablation and coagulation were noted along the mid to lower dermis at the focal penetration depth of 3 mm and along subcutaneous fat to the superficial musculoaponeurotic system or the platysma muscle of the neck at 4.5 mm. Additionally, remarkable pre-focal areas of tissue coagulation were observed in the upper and mid dermis at the focal penetration depth of 3 mm and mid to lower dermis at 4.5 mm. For five HIFU devices, we outlined various patterns of HIFU-induced TIZ formation along pre-focal, focal, and post-focal areas of TM phantom and cadaveric skin of the face and neck.

  6. Effect of the colloids gelatin and HES 130/0.4 on blood coagulation in cardiac surgery patients: a randomized controlled trial.

    PubMed

    Kimenai, D M; Bastianen, G W; Daane, C R; Megens-Bastiaanse, C M; van der Meer, N J M; Scohy, T V; Gerritse, B M

    2013-11-01

    The choice of the prime solution for cardiopulmonary bypass can play an important role in limiting the effect on blood coagulation, but it is still unclear what the effect of colloids on blood coagulation is. The aim of this study was to investigate the effect of synthetic colloids on blood loss and blood coagulation in patients after on-pump coronary artery bypass graft (CABG) procedures. Sixty elective, on-pump CABG patients were randomly assigned to receive the prime solutions lactated Ringer's solution combined with hydroxyethyl starch 130/0.4 (HES, 6% Volulyte, Fresenius Kabi Nederland BV, Zeist, the Netherlands) (HES group) or gelatin (Gelofusin(®), B Braun Melsung AG, Melsungen, Germany) (Gelo group). Blood loss was assessed using post-operative chest tube output; secondary endpoints were number of blood component transfusions, routine coagulation test values and rotation thromboelastometry values (Rotem(®) delta, Pentapharm GmbH, Munich, Germany). Total post-operative chest tube output was 500 ± 420 ml in the HES group versus 465 ± 390 ml in the Gelo group (p = 0.48). No significant differences were observed in any of the routine coagulation tests values, thromboelastometry parameters or number of blood component transfusions between the groups. In this randomized, controlled trial of adults after on-pump CABG procedures, there was no significant difference in blood loss or blood coagulation between the HES group and the Gelo group.

  7. The influence of excipients commonly used in freeze drying on whole blood coagulation dynamics assessed by rotational thromboelastometry.

    PubMed

    Erber, Matthias; Lee, Geoffrey

    2015-09-01

    Lyophilized reagents are used on a daily basis in coagulation diagnostics. They often contain a number of excipients in addition to the active compound. Some of these excipients may, however, influence coagulation dynamics. Besides from plasmatic coagulation bulking agents may influence platelet properties. We therefore studied the influence of a variety of bulking agents (glycine, mannitol, sucrose and trehalose) as well as a surfactant (Tween® 80) on whole blood coagulation using thromboelastometry (ROTEM®) and platelet function analysis (ROTEM® platelet). Both disaccharides as well as Tween® 80 did not influence whole blood coagulation in the concentration range investigated. The addition of glycine and mannitol solutions to the ROTEM® measurement leads to an impaired clot formation as well as overall clot strength while clotting initiation remained barely influenced. Hypertonic glycine and mannitol solutions exhibit different clot formation impairment when correlated to their osmolar concentration and compared to equally osmolar NaCl-solutions. The effect of glycine was assigned to fibrin formation impairment identified with the FIBTEM assay. Platelet function analysis revealed that hypertonic glycine solutions do not alter platelet function but hypertonic mannitol and NaCl solutions do. While the influence observed for glycine may be due to fibrinogen precipitation, the mechanism of mannitol appears to be more complex as platelet function as well as fibrin-based clot formation are influenced. This study therefore demonstrates the necessity to check for coagulation impairment due to compounds contained in lyophilized reagents.

  8. Adaptive force sonorheometry for assessment of whole blood coagulation.

    PubMed

    Mauldin, F William; Viola, Francesco; Hamer, Theresa C; Ahmed, Eman M; Crawford, Shawna B; Haverstick, Doris M; Lawrence, Michael B; Walker, William F

    2010-05-02

    Viscoelastic diagnostics that monitor the hemostatic function of whole blood (WB), such as thromboelastography, have been developed with demonstrated clinical utility. By measuring the cumulative effects of all components of hemostasis, viscoelastic diagnostics have circumvented many of the challenges associated with more common tests of blood coagulation. We describe a new technology, called sonorheometry, that adaptively applies acoustic radiation force to assess coagulation function in WB. The repeatability (precision) of coagulation parameters was assessed using citrated WB samples. A reference range of coagulation parameters, along with corresponding measurements from prothrombin time (PT) and partial thromboplastin time (PTT), were obtained from WB samples of 20 healthy volunteers. In another study, sonorheometry monitored anticoagulation with heparin (0-5 IU/ml) and reversal from varied dosages of protamine (0-10 IU/ml) in heparinized WB (2 IU/ml). Sonorheometry exhibited low CVs for parameters: clot initiation time (TC1), <7%; clot stabilization time (TC2), <6.5%; and clotting angle (theta), <3.5%. Good correlation was observed between clotting times, TC1 and TC2, and PTT (r=0.65 and 0.74 respectively; n=18). Linearity to heparin dosage was observed with average linearity r>0.98 for all coagulation parameters. We observed maximum reversal of heparin anticoagulation at protamine to heparin ratios of 1.4:1 from TC1 (P=0.6) and 1.2:1 from theta (P=0.55). Sonorheometry is a non-contact method for precise assessment of WB coagulation. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Physiological levels of blood coagulation factors IX and X control coagulation kinetics in an in vitro model of circulating tissue factor

    NASA Astrophysics Data System (ADS)

    Tormoen, Garth W.; Khader, Ayesha; Gruber, András; McCarty, Owen J. T.

    2013-06-01

    Thrombosis significantly contributes to cancer morbidity and mortality. The mechanism behind thrombosis in cancer may be circulating tissue factor (TF), as levels of circulating TF are associated with thrombosis. However, circulating TF antigen level alone has failed to predict thrombosis in patients with cancer. We hypothesize that coagulation factor levels regulate the kinetics of circulating TF-induced thrombosis. Coagulation kinetics were measured as a function of individual coagulation factor levels and TF particle concentration. Clotting times increased when pooled plasma was mixed at or above a ratio of 4:6 with PBS. Clotting times increased when pooled plasma was mixed at or above a ratio of 8:2 with factor VII-depleted plasma, 7:3 with factor IX- or factor X-depleted plasmas, or 2:8 with factor II-, V- or VIII-depleted plasmas. Addition of coagulation factors VII, X, IX, V and II to depleted plasmas shortened clotting and enzyme initiation times, and increased enzyme generation rates in a concentration-dependent manner. Only additions of factors IX and X from low-normal to high-normal levels shortened clotting times and increased enzyme generation rates. Our results demonstrate that coagulation kinetics for TF particles are controlled by factor IX and X levels within the normal physiological range. We hypothesize that individual patient factor IX and X levels may be prognostic for susceptibility to circulating TF-induced thrombosis.

  10. Effects of oversulfated and fucosylated chondroitin sulfates on coagulation. Challenges for the study of anticoagulant polysaccharides.

    PubMed

    Fonseca, Roberto J C; Oliveira, Stephan-Nicollas M C G; Pomin, Vitor H; Mecawi, André S; Araujo, Iracema G; Mourão, Paulo A S

    2010-05-01

    We report the effects of a chemically oversulfated chondroitin sulfate and a naturally fucosylated chondroitin sulfate on the coagulation system. The former has been recently identified as a contaminant of heparin preparations and the latter has been proposed as an alternative anticoagulant. The mechanism of action of these polymers on coagulation is complex and target different components of the coagulation system. They have serpin-independent anticoagulant activity, which preponderates in plasma. They also have serpin-dependent anticoagulant activity but differ significantly in the target coagulation protease and preferential serpin. Their anticoagulant effects differ even more markedly when tested as inhibitors of coagulation proteases using plasma as a source of serpins. It is possible that the difference is due to the high availability of fucosylated chondroitin sulfate whereas oversulfated chondroitin sulfate has strong unspecific binding to plasma protein and low availability for the binding to serpins. When tested using a venous thrombosis experimental model, oversulfated chondroitin sulfate is less potent as an antithrombotic agent than fucosylated chondroitin sulfate. These highly sulfated chondroitin sulfates activate factor XII in in vitro assays, based on kallikrein release. However, only fucosylated chondroitin sulfate induces hypotension when intravenously injected into rats. In conclusion, the complexity of the regulatory mechanisms involved in the action of highly sulfated polysaccharides in coagulation requires their analysis by a combination of in vitro and in vivo assays. Our results are relevant due to the urgent need for new anticoagulant drugs or alternative sources of heparin.

  11. A comparative study of coagulation, granular- and powdered-activated carbon for the removal of perfluorooctane sulfonate and perfluorooctanoate in drinking water treatment.

    PubMed

    Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah

    2015-01-01

    Perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) are persistent organic pollutants in the environment and their occurrence causes toxicological effects on humans. We examined different conventional coagulant treatments such as alum, ferric chloride and polyaluminium chloride in removing these compounds. These were then compared with a natural coagulant (Moringa oleifera). We also investigated the powdered-activated carbon (PAC) and granular-activated carbon (GAC) for removing these compounds. At an initial dose of 5 mg/L, polyaluminium chloride led to a higher reduction of PFOS/PFOA compared with alum which in turn was higher than ferric. The removal efficiency increased with the increase in coagulant dose and decrease in pH. M. oleifera was very effective in reducing PFOS and PFOA than conventional coagulants, with a reduction efficiencies of 65% and 72%, respectively, at a dose of 30 mg/L. Both PAC and GAC were very effective in reducing these compounds than coagulations. PAC led to a higher reduction in PFOS and PFOA than GAC due to its greater surface area and shorter internal diffusion distances. The addition of PAC (10 min contact time) with coagulation (at 5 mg/L dosage) significantly increased the removal efficiency, and the maximum removal efficiency was for M. oleifera with 98% and 94% for PFOS and PFOA, respectively. The reduction efficiency of PFOS/PFOA was reduced with the increase in dissolved organic concentration due to the adsorption competition between organic molecules and PFOS/PFOA.

  12. Blocking of platelets or intrinsic coagulation pathway-driven thrombosis does not prevent cerebral infarctions induced by photothrombosis.

    PubMed

    Kleinschnitz, Christoph; Braeuninger, Stefan; Pham, Mirko; Austinat, Madeleine; Nölte, Ingo; Renné, Thomas; Nieswandt, Bernhard; Bendszus, Martin; Stoll, Guido

    2008-04-01

    Models of photochemically-induced thrombosis are widely used in cerebrovascular research. Photothrombotic brain infarctions can be induced by systemic application of photosensitizing dyes followed by focal illumination of the cerebral cortex. Although the ensuing activation of platelets is well established, their contribution for thrombosis and tissue damage has not formally been proved. Infarction to the cerebral cortex was induced in mice by Rose Bengal and a cold light source. To assess the functional role of platelets, animals were platelet-depleted by anti-GPIbalpha antibodies or treated with GPIIb/IIIa-blocking F(ab)(2) fragments. The significance of the plasmatic coagulation cascade was determined by using blood coagulation factor XII (FXII)-deficient mice or heparin. Infarct development and infarct volumes were determined by serial MRI and conventional and electron microscopy. There was no difference in development and final size of photothrombotic infarctions in mice with impaired platelet function. Moreover, deficiency of FXII, which initiates the intrinsic pathway of coagulation and is essential for thrombus formation, or blockade of FXa, the key protease during the waterfall cascade of plasmatic coagulation, by heparin likewise did not affect lesion development. Our data demonstrate that platelet activation, factor XII-driven thrombus formation, and plasmatic coagulation pathways downstream of FX are not a prerequisite for ensuing tissue damage in models of photothrombotic vessel injury indicating that other pathomechanisms are involved. We suggest that this widely used model does not depend on platelet- or plasmatic coagulation-derived thrombosis.

  13. Measurement of the coagulation dynamics of bovine liver using the modified microscopic Beer-Lambert law.

    PubMed

    Terenji, Albert; Willmann, Stefan; Osterholz, Jens; Hering, Peter; Schwarzmaier, Hans-Joachim

    2005-06-01

    During heating, the optical properties of biological tissues change with the coagulation state. In this study, we propose a technique, which uses these changes to monitor the coagulation process during laser-induced interstitial thermotherapy (LITT). Untreated and coagulated (water bath, temperatures between 35 degrees C and 90 degrees C for 20 minutes.) samples of bovine liver tissue were examined using a Nd:YAG (lambda = 1064 nm) frequency-domain reflectance spectrometer. We determined the time integrated intensities (I(DC)) and the phase shifts (Phi) of the photon density waves after migration through the tissue. From these measured quantities, the time of flight (TOF) of the photons and the absorption coefficients of the samples were derived using the modified microscopic Beer-Lambert law. The absorption coefficients of the liver samples decreased significantly with the temperature in the range between 50 degrees C and 70 degrees C. At the same time, the TOF of the investigated photos was found increased indicating an increased scattering. The coagulation dynamics could be well described using the Arrhenius formalism with the activation energy of 106 kJ/mol and the frequency factor of 1.59 x 10(13)/second. Frequency-domain reflectance spectroscopy in combination with the modified microscopic Beer-Lambert (MBL) is suitable to measure heat induced changes in the absorption and scattering properties of bovine liver in vitro. The technique may be used to monitor the coagulation dynamics during local thermo-coagulation in vivo. Copyright 2005 Wiley-Liss, Inc.

  14. Activation of coagulation and endothelium with concurrent impairment of anticoagulant mechanisms in patients with typhoid fever.

    PubMed

    de Jong, Hanna K; Parry, Chris M; van der Vaart, Thomas W; Kager, Liesbeth M; van den Ende, Stannie J; Maude, Rapeephan R; Wijedoru, Lalith; Ghose, Aniruddha; Hassan, Mohammed U; Hossain, Mohammed A; Dondorp, Arjan M; Baker, Steve; Faiz, M Abul; Meijers, Joost C M; Wiersinga, W Joost

    2018-05-07

    Typhoid fever caused by Salmonella Typhi remains a major burden worldwide. Gastrointestinal bleeding can be seen in up to 10 percent of patients and may be fatal. The coagulopathy, which may be the driver of this severe complication in patients with typhoid fever, however is ill defined. The aim of this study was to evaluate the activation of coagulation, anticoagulation, and fibrinolysis in patients with acute typhoid fever. Parameters of coagulation and fibrinolysis were measured in 28 hospitalized patients with culture-confirmed or PCR-confirmed typhoid fever and compared to 38 age- and sex-matched healthy volunteers. Patients demonstrated activation of the coagulation system, as reflected by elevated in vitro thrombin generation and high plasma levels of fibrinogen, D-dimer and prothrombin fragment F1 + 2 in concert with consumption of coagulation factors resulting in a prolonged prothrombin-time and activated-partial-thromboplastin-time. Concurrently, the anticoagulant proteins, protein C and antithrombin, were significantly lower in comparison to healthy controls. Patients also demonstrated evidence of activation and inhibition of fibrinolysis and a marked activation of endothelial cells. The extent of coagulation activation was associated with the course of the disease, repeated testing during convalescence showed a return toward normal values. Activation of coagulation is an important clinical feature of typhoid fever and is associated with severity of disease. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. ANFIS-based modelling for coagulant dosage in drinking water treatment plant: a case study.

    PubMed

    Heddam, Salim; Bermad, Abdelmalek; Dechemi, Noureddine

    2012-04-01

    Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.

  16. Normal Coagulation

    DTIC Science & Technology

    2014-09-04

    LO TTIN G with vitamin K antagonist...confidential until formal publication.6 F CHAPTER 34 Normal Coagulation 531 SE C T IO N 7 B LEED IN G A N D C LO TTIN G Table 34-1 Procoagulant...formal publication.8 F CHAPTER 34 Normal Coagulation 533 SE C T IO N 7 B LEED IN G A N D C LO TTIN G Figure 34-4 Vitamin K–dependent com-

  17. Tail Behaviour of Self-Similar Profiles with Infinite Mass for Smoluchowski's Coagulation Equation

    NASA Astrophysics Data System (ADS)

    Throm, Sebastian

    2018-03-01

    In this article, we consider self-similar profiles to Smoluchowski's coagulation equation for which we derive the precise asymptotic behaviour at infinity. More precisely, we look at so-called fat-tailed profiles which decay algebraically and as a consequence have infinite total mass. The results only require mild assumptions on the coagulation kernel and thus cover a large class of rate kernels.

  18. [Abnormality of blood coagulation indexes in patients with de novo acute leukemia and its clinical significance].

    PubMed

    Xiao, Fang-Fang; Hu, Kai-Xun; Guo, Mei; Qiao, Jian-Hui; Sun, Qi-Yun; Ai, Hui-Sheng; Yu, Chang-Lin

    2013-04-01

    To explore hemorrhage risk and the clinical significance of abnormal change of prothrombin time (PT), activated partial thromboplastin time (APTT), plasma fibrinogen (FIB), plasma thrombin time (TT) and d-dimer (D-D) in de novo acute leukemia (except for APL), the different bleeding manifestations of 114 cases of de novo acute leukemia with different coagulation indexes were analyzed retrospectively. The correlation between these blood coagulation indexes and the possible correlative clinical characteristics were analysed, including age, sex, type of acute leukemia, initial white blood cell(WBC) and platelet(Plt) count, the proportion of blast cells in bone marrow and cytogenetic abnormality of patients at diagnosis. The results indicated that the incidence of abnormal blood coagulation was as high as 78.1% for de novo AL patients. These patients with 5 normal blood coagulation indexes may have mild bleeding manifestation, but the more abnormal indexes, the more severe bleeding. Both PT and D-D were sensitive indexes for diagnosis of level II bleeding. Incidence of abnormal blood coagulation significantly correlates with the proportion of blast cells in bone marrow (χ(2) = 4.184, OR = 1.021, P < 0.05) and more with D-D (P < 0.01), while age, sex, type of AL, WBC count, Plt count and abnormality of cytogenetics did not correlate with abnormal blood coagulation. It is concluded that the coagulation and fibrinolysis are abnormal in most patients with de novo acute leukemia. More abnormal indexes indicate more severe bleeding, and both PT and D-D are sensitive indexes for diagnosis of level II bleeding. Higher proportion of blast cells in bone marrow predicts higher incidence of abnormal blood clotting. Acute leukemia with elderly age, high white blood cell count and adverse cytogenetics do not predict severer abnormal blood clotting. Detection of PT, APTT, TT, FIB, and D-D may help to judge whether the patients are in a state of hypercoagulability or disseminated intravenous coagulation, which will provide experiment evidences for early intervention and medication.

  19. Investigation of enteric adenovirus and poliovirus removal by coagulation processes and suitability of bacteriophages MS2 and φX174 as surrogates for those viruses.

    PubMed

    Shirasaki, N; Matsushita, T; Matsui, Y; Marubayashi, T; Murai, K

    2016-09-01

    We evaluated the removal of enteric adenovirus (AdV) type 40 and poliovirus (PV) type 1 by coagulation, using water samples from 13 water sources for drinking water treatment plants in Japan. The behaviors of two widely accepted enteric virus surrogates, bacteriophages MS2 and φX174, were compared with the behaviors of AdV and PV. Coagulation with polyaluminum chloride (PACl, basicity 1.5) removed AdV and PV from virus-spiked source waters: the infectious AdV and PV removal ratios evaluated by means of a plaque-forming-unit method were 0.1-1.4-log10 and 0.5-2.4-log10, respectively. A nonsulfated high-basicity PACl (basicity 2.1) removed infectious AdV and PV more efficiently than did other commercially available PACls (basicity 1.5-2.1), alum, and ferric chloride. The MS2 removal ratios tended to be larger than those of AdV and PV, partly because of differences in the hydrophobicities of the virus particles and the sensitivity of the virus to the virucidal activity of PACl; the differences in removal ratios were not due to differences in the surface charges of the virus particles. MS2, which was more hydrophobic than the other viruses, was inactivated during coagulation with PACl. Therefore, MS2 does not appear to be an appropriate surrogate for AdV and PV during coagulation. In contrast, because φX174, like AdV and PV, was not inactivated during coagulation, and because the hydrophobicity of φX174 was similar to or somewhat lower than the hydrophobicities of AdV and PV, the φX174 removal ratios tended to be similar to or somewhat smaller than those of the enteric viruses. Therefore, φX174 is a potential conservative surrogate for AdV and PV during coagulation. In summary, the surface hydrophobicity of virus particles and the sensitivity of the virus to the virucidal activity of the coagulant are probably important determinants of the efficiency of virus removal during coagulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Performance of titanium salts compared to conventional FeCl3 for the removal of algal organic matter (AOM) in synthetic seawater: Coagulation performance, organic fraction removal and floc characteristics.

    PubMed

    Chekli, L; Corjon, E; Tabatabai, S A A; Naidu, G; Tamburic, B; Park, S H; Shon, H K

    2017-10-01

    During algal bloom periods, operation of seawater reverse osmosis (SWRO) pretreatment processes (e.g. ultrafiltration (UF)) has been hindered due to the high concentration of algal cells and algal organic matter (AOM). The present study evaluated for the first time the performance of titanium salts (i.e. titanium tetrachloride (TiCl 4 ) and polytitanium tetrachloride (PTC)) for the removal of AOM in seawater and results were compared with the conventional FeCl 3 coagulant. Previous studies already demonstrated that titanium salts not only provide a cost-effective alternative to conventional coagulants by producing a valuable by-product but also minimise the environmental impact of sludge production. Results from this study showed that both TiCl 4 and PTC achieved better performance than FeCl 3 in terms of turbidity, UV 254 and dissolved organic carbon (DOC) removal at similar coagulant dose. Liquid chromatography - organic carbon detection (LC-OCD) was used to determine the removal of AOM compounds based on their molecular weight (MW). This investigation revealed that both humic substances and low MW organics were preferentially removed (i.e. up to 93% removal) while all three coagulants showed poorer performance for the removal of high MW biopolymers (i.e. less than 50% removal). The detailed characterization of flocs indicated that both titanium coagulants can grow faster, reach larger size and present a more compact structure, which is highly advantageous for the design of smaller and more compact mixing and sedimentation tanks. Both titanium coagulants also presented a higher ability to withstand shear force, which was related to the higher amount of DOC adsorbed with the aggregated flocs. Finally, TiCl 4 had a better recovery after breakage suggesting that charge neutralization may be the dominant mechanism for this coagulant, while the lower recovery of both PTC and FeCl 3 indicated that sweep flocculation is also a contributing mechanism for the coagulation of AOM. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. [Coagulation Monitoring and Bleeding Management in Cardiac Surgery].

    PubMed

    Bein, Berthold; Schiewe, Robert

    2018-05-01

    The transfusion of allogeneic blood products is associated with increased morbidity and mortality. An impaired hemostasis is frequently found in patients undergoing cardiac surgery and may in turn cause bleeding and transfusions. A goal directed coagulation management addressing the often complex coagulation disorders needs sophisticated diagnostics. This may improve both patients' outcome and costs. Recent data suggest that coagulation management based on a rational algorithm is more effective than traditional therapy based on conventional laboratory variables such as PT and INR. Platelet inhibitors, cumarins, direct oral anticoagulants and heparin need different diagnostic and therapeutic approaches. An algorithm specifically developed for use during cardiac surgery is presented. Georg Thieme Verlag KG Stuttgart · New York.

  2. Study on Coagulant Dosing Control System of Micro Vortex Water Treatment

    NASA Astrophysics Data System (ADS)

    Fengping, Hu; Qi, Fan; Wenjie, Hu; Xizhen, He; Hongling, Dai

    2018-03-01

    In view of the characteristics of nonlinearity, large time delay and multi disturbance in the process of coagulant dosing in water treatment, it is difficult to control the dosage of coagulant. According to the four indexes of raw water quality parameters (raw water flow, turbidity, pH value) and turbidity of sedimentation tank, the micro vortex coagulation dosing control model is constructed based on BP neural network and GA. The forecast results of BP neural network model are ideal, and after the optimization of GA, the prediction accuracy of the model is partly improved. The prediction error of the optimized network is ±0.5 mg/L, and has a better performance than non-optimized network.

  3. Advances in radio frequency tumor ablation therapy: technical considerations, strategies for increasing coagulation necrosis volume, and preliminary clinical results

    NASA Astrophysics Data System (ADS)

    Goldberg, S. Nahum; Gazelle, G. Scott

    1998-04-01

    Radiofrequency (RF) tumor ablation has been demonstrated as a reliable method for creating thermally induced coagulation necrosis using either a percutaneous approach with image- guidance or direct surgical application of thin electrodes into treated tissues. Early clinical trials with this technology have studied the treatment of hepatic, cerebral, and bony malignancies. The extent of coagulation necrosis induced with conventional monopolar radiofrequency electrodes is dependent on overall energy deposition, the duration of RF application, and RF electrode tip length and gauge. This article will discuss these technical considerations with the goal of defining optimal parameters for RF ablation. Strategies to further increase induced coagulation necrosis including: multiprobe and bipolar arrays, and internally-cooled RF electrodes, with or without pulsed-RF or cluster technique will be presented. The development and laboratory results for many of these radiofrequency techniques, initial clinical results, and potential biophysical limitations to RF induced coagulation, such as perfusion mediated tissue cooling (vascular flow) will likewise be discussed.

  4. Coagulant from Leucaena leucocephala for Chromium Removal

    NASA Astrophysics Data System (ADS)

    Razak, N. H. Abd; Khairuddin, N.; Ismail, K. N.; Musa, M.

    2018-05-01

    This research investigated the effectiveness of leucaena leucocephala as a natural coagulant for chromium removal. Leucaena leucocephala is a permanent non-climbing shrub tree which is wild and abundant in Malaysia and commonly known as petai belalang. Coagulation experiment using jar test were performed where the effect of coagulant dosage and pH were examined. The parameters investigated were suspended solid (SS), chemical oxygen demand (COD), biological oxygen demand (BOD), turbidity and chromium content. The optimum of leucaena leucocephala coagulant dosage for removal of suspended solid, turbidity, COD, BOD and Chromium is at range 400-600 mg/L which yielded 45, 31.4, 38.5, 27.5 and 4.05% removal respectively. While the optimum pH is at pH 2-4 (acidic) which give 33.3, 26.8, 33.75, 31.4 and 14.06% removal of suspended solid, COD, BOD, turbidity and chromium content respectively. It is concluded that the leucaena leucocephala showed tremendous potential for chromium removal.

  5. Effects of endogenous small molecular compounds on the rheological properties, texture and microstructure of soymilk coagulum: Removal of phytate using ultrafiltration.

    PubMed

    Wang, Ruican; Guo, Shuntang

    2016-11-15

    This study aims to clarify the roles played by endogenous small molecular components in soymilk coagulation process and the properties of gels. Soymilk samples with decreasing levels of small molecules were prepared by ultrafiltration, to reduce the amount of phytate and salts. CaSO4-induced coagulation process was analyzed using rheological methods. Results showed that removal of free small molecules decreased the activation energy of protein coagulation, resulting in accelerated reaction and increased gel strength. However, too fast a reaction led to the drop in storage modulus (G'). Microscopic observation suggested that accelerated coagulation generated a coarse and non-uniform gel network with large pores. This network could not hold much water, leading to serious syneresis. Endogenous small molecules in soymilk were vital in the fine gel structure. Coagulation rate could be controlled by adjusting the amount of small molecules to obtain tofu products with the optimal texture. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Reduction of Turbidity of Water Using Locally Available Natural Coagulants

    PubMed Central

    Asrafuzzaman, Md.; Fakhruddin, A. N. M.; Hossain, Md. Alamgir

    2011-01-01

    Turbidity imparts a great problem in water treatment. Moringa oleifera, Cicer arietinum, and Dolichos lablab were used as locally available natural coagulants in this study to reduce turbidity of synthetic water. The tests were carried out, using artificial turbid water with conventional jar test apparatus. Optimum mixing intensity and duration were determined. After dosing water-soluble extracts of Moringa oleifera, Cicer arietinum, and Dolichos lablab reduced turbidity to 5.9, 3.9, and 11.1 nephelometric turbidity unit (NTU), respectively, from 100 NTU and 5, 3.3, and 9.5, NTU, respectively, after dosing and filtration. Natural coagulants worked better with high, turbid, water compare to medium, or low, turbid, water. Highest turbidity reduction efficiency (95.89%) was found with Cicer arietinum. About 89 to 96% total coliform reduction were also found with natural coagulant treatment of turbid water. Using locally available natural coagulants, suitable, easier, and environment friendly options for water treatment were observed. PMID:23724307

  7. Modeling intracavitary heating of the uterus by means of a balloon catheter

    NASA Astrophysics Data System (ADS)

    Olsrud, Johan; Friberg, Britt; Rioseco, Juan; Ahlgren, Mats; Persson, Bertil R. R.

    1999-01-01

    Balloon thermal endometrial destruction (TED) is a recently developed method to treat heavy menstrual bleeding (menorrhagia). Numerical simulations of this treatment by use of the finite element method were performed. The mechanical deformation and the resulting stress distribution when a balloon catheter is expanded within the uterine cavity was estimated from structural analysis. Thermal analysis was then performed to estimate the depth of tissue coagulation (temperature > 55 degree(s)C) in the uterus during TED. The estimated depth of coagulation, after 30 min heating with an intracavity temperature of 75 degree(s)C, was approximately 9 mm when blood flow was disregarded. With uniform normal blood flow, the depth of coagulation decreased to 3 - 4 mm. Simulations with varying intracavity temperatures and blood flow rates showed that both parameters should be of major importance to the depth of coagulation. The influence of blood flow was less when the pressure due to the balloon was also considered (5 - 6 mm coagulation depth with normal blood flow).

  8. Multiple roles of the coagulation protease cascade during virus infection.

    PubMed

    Antoniak, Silvio; Mackman, Nigel

    2014-04-24

    The coagulation cascade is activated during viral infections. This response may be part of the host defense system to limit spread of the pathogen. However, excessive activation of the coagulation cascade can be deleterious. In fact, inhibition of the tissue factor/factor VIIa complex reduced mortality in a monkey model of Ebola hemorrhagic fever. Other studies showed that incorporation of tissue factor into the envelope of herpes simplex virus increases infection of endothelial cells and mice. Furthermore, binding of factor X to adenovirus serotype 5 enhances infection of hepatocytes but also increases the activation of the innate immune response to the virus. Coagulation proteases activate protease-activated receptors (PARs). Interestingly, we and others found that PAR1 and PAR2 modulate the immune response to viral infection. For instance, PAR1 positively regulates TLR3-dependent expression of the antiviral protein interferon β, whereas PAR2 negatively regulates expression during coxsackievirus group B infection. These studies indicate that the coagulation cascade plays multiple roles during viral infections.

  9. Single session treatment for bleeding hemorrhoids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinstein, S.J.; Rypins, E.B.; Houck, J.

    1987-12-01

    Fifty consecutive outpatients with bleeding internal hemorrhoids were prospectively treated with a single application of rubber band ligation or infrared coagulation. Complete follow-up observation was obtained in 48 patients (23 underwent rubber band ligation and 25 underwent infrared coagulation). At one month after treatment, 22 patients who underwent rubber band ligation and 16 who underwent infrared coagulation, were symptomatically improved (p less than 0.05). At six months, 15 patients who had undergone rubber band ligation and ten who had infrared coagulation treatment, remained improved (p less than 0.05). There was no statistical difference in the discomfort experienced by either groupmore » during or after the procedure as determined by a self-assessment scale. Two patients who underwent rubber band ligation experienced complications--a thrombosed external hemorrhoid developed in one patient and another had delayed rectal bleeding. Although associated with occasional complications after treatment, rubber band ligation is more effective than in infrared coagulation for single session treatment of bleeding internal hemorrhoids.« less

  10. Blood coagulation factor XII drives adaptive immunity during neuroinflammation via CD87-mediated modulation of dendritic cells

    PubMed Central

    Göbel, Kerstin; Pankratz, Susann; Asaridou, Chloi-Magdalini; Herrmann, Alexander M.; Bittner, Stefan; Merker, Monika; Ruck, Tobias; Glumm, Sarah; Langhauser, Friederike; Kraft, Peter; Krug, Thorsten F.; Breuer, Johanna; Herold, Martin; Gross, Catharina C.; Beckmann, Denise; Korb-Pap, Adelheid; Schuhmann, Michael K.; Kuerten, Stefanie; Mitroulis, Ioannis; Ruppert, Clemens; Nolte, Marc W.; Panousis, Con; Klotz, Luisa; Kehrel, Beate; Korn, Thomas; Langer, Harald F.; Pap, Thomas; Nieswandt, Bernhard; Wiendl, Heinz; Chavakis, Triantafyllos; Kleinschnitz, Christoph; Meuth, Sven G.

    2016-01-01

    Aberrant immune responses represent the underlying cause of central nervous system (CNS) autoimmunity, including multiple sclerosis (MS). Recent evidence implicated the crosstalk between coagulation and immunity in CNS autoimmunity. Here we identify coagulation factor XII (FXII), the initiator of the intrinsic coagulation cascade and the kallikrein–kinin system, as a specific immune cell modulator. High levels of FXII activity are present in the plasma of MS patients during relapse. Deficiency or pharmacologic blockade of FXII renders mice less susceptible to experimental autoimmune encephalomyelitis (a model of MS) and is accompanied by reduced numbers of interleukin-17A-producing T cells. Immune activation by FXII is mediated by dendritic cells in a CD87-dependent manner and involves alterations in intracellular cyclic AMP formation. Our study demonstrates that a member of the plasmatic coagulation cascade is a key mediator of autoimmunity. FXII inhibition may provide a strategy to combat MS and other immune-related disorders. PMID:27188843

  11. Hibiscus rosa- sinensis leaf extract as coagulant aid in leachate treatment

    NASA Astrophysics Data System (ADS)

    Awang, Nik Azimatolakma; Aziz, Hamidi Abdul

    2012-12-01

    Hibiscus rosa- sinensis is a biodegradable material that has remained untested for flocculating properties. The objective of this study is to examine the efficiency of coagulation-flocculation processes for the removal of color, iron (Fe3+), suspended solids, turbidity and ammonia nitrogen(NH3-N), from landfill leachate using 4,000 mg/L alum in conjunction with H. rosa- sinensis leaf extract (HBaqs). Hydroxyl (O-H) and (carboxyl) C=O functional groups along the HBaqs chain help to indulge flocculating efficiency of HBaqs via bridging. The experiments confirm the positive coagulation properties of HBaqs. The Fe3+ removal rate using 4,000 mg/L alum as sole coagulant was approximately 60 %, and increased to 100 % when 4,000 mg/L alum was mixed with 500 mg/L HBaqs. By mixing, 4,000 mg/L alum with 100-500 mg/L HBaqs, 72 % of SS was removed as compared with only 45 % reduction using 4,000 mg/L alum as sole coagulant.

  12. The application of bioflocculant for the removal of humic acids from stabilized landfill leachates.

    PubMed

    Zouboulis, Anastasios I; Chai, Xiao-Li; Katsoyiannis, Ioannis A

    2004-01-01

    The evaluation of bioflocculant, in comparison with traditional inorganic coagulants, for the removal of humic acids from landfill leachates stabilized by biological treatment, was performed using conventional jar-test coagulation experiments. The optimized conditions (pH and coagulant dosage) were identified for the treatment of synthetic solutions as well as for biologically pre-treated landfill leachates. It was found that the application of bioflocculant was quite efficient in the removal of humic acids from synthetic solutions as well as in the reduction of COD content from real landfill leachates. The optimal pH value was found to be between 7 and 7.5, while a 20 mg/l bioflocculant dosage was sufficient in providing more than 85% humic acid removal. The results were comparable with those obtained by the application of conventional coagulants such as alum or polyaluminum chloride; therefore, bioflocculant can be considered as a viable alternative in the treatment of landfill leachates applying coagulation.

  13. Effect of magnetic bracelets on the coagulation and anticoagulation systems of the blood of patients with hypertension

    NASA Technical Reports Server (NTRS)

    Bublis, V. V.; Zabrodina, L. V.; Platonova, A. T.; Meyerova, Y. A.

    1974-01-01

    The data which have been obtained on the influence of magnetic bracelets on the coagulation and anticoagulation systems of the blood indicate that the wearing of magnetic bracelets results in a decrease in the coagulation activity of the blood and an increase in the activity of the anticoagulation system. These changes must be viewed as favorable for patients with cardiovascular pathology.

  14. Combined effects of coagulation and adsorption on ultrafiltration membrane fouling control and subsequent disinfection in drinking water treatment.

    PubMed

    Xing, Jiajian; Liang, Heng; Cheng, Xiaoxiang; Yang, Haiyan; Xu, Daliang; Gan, Zhendong; Luo, Xinsheng; Zhu, Xuewu; Li, Guibai

    2018-06-02

    This study investigated the combined effects of coagulation and powdered activated carbon (PAC) adsorption on ultrafiltration (UF) membrane fouling control and subsequent disinfection efficiency through filtration performance, dissolved organic carbon (DOC) removal, fluorescence excitation-emission matrix (EEM) spectroscopy, and disinfectant curve. The fouling behavior of UF membrane was comprehensively analyzed especially in terms of pollutant removal and fouling reversibility to understand the mechanism of fouling accumulation and disinfectant dose reduction. Pre-coagulation with or without adsorption both achieved remarkable effect of fouling mitigation and disinfection dose reduction. The two pretreatments were effective in total fouling control and pre-coagulation combined with PAC adsorption even decreased hydraulically irreversible fouling notably. Besides, pre-coagulation decreased residual disinfectant decline due to the removal of hydrophobic components of natural organic matters (NOM). Pre-coagulation combined with adsorption had a synergistic effect on further disinfectant decline rate reduction and decreased total disinfectant consumption due to additional removal of hydrophilic NOM by PAC adsorption. The disinfectant demand was further reduced after membrane. These results show that membrane fouling and disinfectant dose can be reduced in UF coupled with pretreatment, which could lead to the avoidance of excessive operation cost disinfectant dose for drinking water supply.

  15. Effects of alum coagulation on speciation and distribution of trihalomethanes (THMs) and haloacetic acids (HAAs).

    PubMed

    Gang, Dianchen; Clevenger, Thomas E; Banerji, Shankha K

    2005-01-01

    The impacts of alum coagulation on the distribution of disinfection by-products (DBPs), trihalomethanes (THMs), and haloacetic acids (HAAs) were evaluated under controlled chlorination conditions using four surface waters. Among the nine HAAs found in waters, dihaloacetic acids (X2AAs) have been found to be the dominant species in all of the raw and alum treated waters. Alum coagulation tends to remove more monohaloacetic acids (XAAs) and trihaloacetic acids (X3AAs) precursors than that of dihaloacetic acids (X2AAs). Alum coagulation treated water had a lower HAA9/TTHM ratio compared with that of the raw water. The increase of THM bromine incorporation factors (BIFalpha) value of alum treated water was statistically significant in comparison with the raw water. On average, BIFalpha increased by 54% after the alum coagulation process in these four different waters. This indicated that THM speciations shifted in favor of the more brominated compounds. However, alum coagulation treatment process had less effect on HAA bromi ne incorporation factors (BIFbeta)than it did on BIFalpha. Bromine incorporation factor (BIF) values decreased with time in the THM and HAA formation processes, especially within the first 10 h of the reaction time. This suggested that brominated THMs or HAAs formed faster than the chlorinated species in the initial period.

  16. Clay-catalyzed reactions of coagulant polymers during water chlorination

    USGS Publications Warehouse

    Lee, J.-F.; Liao, P.-M.; Lee, C.-K.; Chao, H.-P.; Peng, C.-L.; Chiou, C.T.

    2004-01-01

    The influence of suspended clay/solid particles on organic-coagulant reactions during water chlorination was investigated by analyses of total product formation potential (TPFP) and disinfection by-product (DBP) distribution as a function of exchanged clay cation, coagulant organic polymer, and reaction time. Montmorillonite clays appeared to act as a catalytic center where the reaction between adsorbed polymer and disinfectant (chlorine) was mediated closely by the exchanged clay cation. The transition-metal cations in clays catalyzed more effectively than other cations the reactions between a coagulant polymer and chlorine, forming a large number of volatile DBPs. The relative catalytic effects of clays/solids followed the order Ti-Mont > Fe-Mont > Cu-Mont > Mn-Mont > Ca-Mont > Na-Mont > quartz > talc. The effects of coagulant polymers on TPFP follow the order nonionic polymer > anionic polymer > cationic polymer. The catalytic role of the clay cation was further confirmed by the observed inhibition in DBP formation when strong chelating agents (o-phenanthroline and ethylenediamine) were added to the clay suspension. Moreover, in the presence of clays, total DBPs increased appreciably when either the reaction time or the amount of the added clay or coagulant polymer increased. For volatile DBPs, the formation of halogenated methanes was usually time-dependent, with chloroform and dichloromethane showing the greatest dependence. ?? 2003 Elsevier Inc. All rights reserved.

  17. Changes in pre- and post-donation platelet function in plateletpheresis donors.

    PubMed

    Zhou, Q; Yu, X; Cai, Y; Liu, L

    2017-11-01

    This study aimed to investigate the changes of platelet (PLT) function and coagulation time before and after plateletpheresis donation. The healthy donors were divided into four groups according to the annual number of plateletpheresis donation: 20 times group, 15 times group, 10 times group and 5 times group. The healthy non-blood donors were selected as controls. The donation interval was 14 days. The blood samples were collected before plateletpheresis donation and after 30min, 7 d, and 14 d of donation for determination of coagulation time, PLT function, plasma protein, serum iron and blood routine change. After 30min of plateletpheresis donation, the PLT function decreased and the coagulation time was prolonged. However, PLT function recovered to the pre-collection after 7 d of plateletpheresis donation and coagulation time recovered to the pre-collection after 14 d of plateletpheresis donation. Additionally, there was no difference regarding blood coagulation time and PLT function among blood donors and controls. The plasma protein and serum iron levels in 20 times and 15 times groups were within the normal reference range. The frequency of plateletpheresis donation will not affect PLT function, coagulation time, plasma protein and serum iron in donors. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Effect of fibrinogen on blood coagulation detected by optical coherence tomography.

    PubMed

    Xu, Xiangqun; Teng, Xiangshuai

    2015-05-21

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d1/e) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0-8 g L(-1)); and 2) native plasma with commercial Fbg added (0-8 g L(-1)). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels.

  19. Coagulation Management in Jersey Calves: An ex vivo Study.

    PubMed

    Gröning, Sabine; Maas, Judith; van Geul, Svenja; Rossaint, Rolf; Steinseifer, Ulrich; Grottke, Oliver

    2017-01-01

    Jersey calves are frequently used as an experimental animal model for in vivo testing of cardiac assist devices or orthopedic implants. In this ex vivo study, we analyzed the coagulation system of the Jersey calves and the potential of human-based coagulation management to circumvent perioperative bleeding complications during surgery. Experimental Procedure: Blood from 7 Jersey calves was subjected to standard laboratory tests and thromboelastometry analysis. An ex vivo model of dilutional coagulopathy was used to study the effects of fibrinogen or prothrombin complex concentrate supplementation. Fibrinolysis was induced with tissue plasminogen activator to identify potential therapeutic strategies involving tranexamic acid or aprotinin. Furthermore, anticoagulation strategies were evaluated by incubating the blood samples with dabigatran or rivaroxaban. Baseline values for thromboelastometry and standard laboratory parameters, including prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin III, and D-dimers, were established. Fifty percent diluted blood showed a statistically significant impairment of hemostasis. The parameters significantly improved after the administration of fibrinogen or prothrombin complex concentrate. Tranexamic acid and aprotinin ameliorated tissue plasminogen activator-induced fibrinolysis. Both dabigatran and rivaroxaban significantly prolonged the coagulation parameters. In this ex vivo study, coagulation factors, factor concentrate, antifibrinolytic reagents, and anticoagulants regularly used in the clinic positively impacted coagulation parameters in Jersey calf blood. © 2017 S. Karger AG, Basel.

  20. Selection of the surface water treatment technology - a full-scale technological investigation.

    PubMed

    Pruss, Alina

    2015-01-01

    A technological investigation was carried out over a period of 2 years to evaluate surface water treatment technology. The study was performed in Poland, in three stages. From November 2011 to July 2012, for the first stage, flow tests with a capacity of 0.1-1.5 m³/h were performed simultaneously in three types of technical installations differing by coagulation modules. The outcome of the first stage was the choice of the technology for further investigation. The second stage was performed between September 2012 and March 2013 on a full-scale water treatment plant. Three large technical installations, operated in parallel, were analysed: coagulation with sludge flotation, micro-sand ballasted coagulation with sedimentation, coagulation with sedimentation and sludge recirculation. The capacity of the installations ranged from 10 to 40 m³/h. The third stage was also performed in a full-scale water treatment plant and was aimed at optimising the selected technology. This article presents the results of the second stage of the full-scale investigation. The critical treatment process, for the analysed water, was the coagulation in an acidic environment (6.5 < pH < 7.0) carried out in a system with rapid mixing, a flocculation chamber, preliminary separation of coagulation products, and removal of residual suspended solids through filtration.

  1. A survey of coagulation laboratory practices and satisfaction ratings of member laboratories of the Thailand National External Quality Assessment Scheme for blood coagulation.

    PubMed

    Chuntarut, A; Tientadakul, P; Wongkrajang, P

    2016-06-01

    The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.

  2. Coagulation profiles of healthy Andalusian donkeys are different than those of healthy horses.

    PubMed

    Mendoza, F J; Perez-Ecija, R A; Monreal, L; Estepa, J C

    2011-01-01

    Coagulation disorders are frequently diagnosed, especially in hospitalized equidae, and result in increased morbidity and mortality. However, hemostatic reference intervals have not been established for donkeys yet. To determine whether the most common coagulation parameters used in equine practice are different between healthy donkeys and horses. Thirty-eight healthy donkeys and 29 healthy horses. Blood samples were collected to assess both coagulation and fibrinolytic systems by determination of platelet count, fibrinogen concentration, clotting times (prothrombin time [PT] and activated partial thromboplastin time [aPTT]), fibrin degradation products (FDP) and D-Dimer concentrations. PT and aPTT in donkeys were significantly (P < .05) shorter than those of horses. In contrast, FDP and D-Dimer concentrations were significantly (P < .05) higher in donkeys than in horses. The coagulation parameters most commonly determined in equine practice are different in donkeys compared with horses. Thus, the use of normal reference ranges reported previously for healthy horses in donkeys might lead to a misdiagnosis of coagulopathy in healthy donkeys, and unnecessary treatments in sick donkeys. This is the first report of normal coagulation profile results in donkeys, and further studies are warranted to elucidate the physiological mechanisms of the differences observed between donkeys and horses. Copyright © 2011 by the American College of Veterinary Internal Medicine.

  3. HEPATIC FUNCTION AFTER GENETICALLY-ENGINEERED PIG LIVER TRANSPLANTATION IN BABOONS

    PubMed Central

    Ekser, Burcin; Echeverri, Gabriel J.; Hassett, Andrea Cortese; Yazer, Mark H.; Long, Cassandra; Meyer, Michael; Ezzelarab, Mohamed; Lin, Chih Che; Hara, Hidetaka; van der Windt, Dirk J.; Dons, Eefje M.; Phelps, Carol; Ayares, David; Cooper, David K.C.; Gridelli, Bruno

    2010-01-01

    Background If ‘bridging’ to allotransplantation is to be achieved by a pig liver xenograft, adequate hepatic function needs to be assured. Methods We have studied hepatic function in baboons after transplantation of livers from α1,3-galactosyltransferase gene-knockout (GTKO,n=1) or GTKO pigs transgenic for CD46 (GTKO/CD46,n=5). Monitoring was by liver function tests and coagulation parameters. Pig-specific proteins in the baboon serum/plasma were identified by Western blot. In 4 baboons, coagulation factors were measured. The results were compared with values from healthy humans, baboons, and pigs. Results Recipient baboons died or were euthanized after 4-7 days following internal bleeding associated with profound thrombocytopenia. However, parameters of liver function, including coagulation, remained in the near-normal range, except for some cholestasis. Western blot demonstrated that pig proteins (albumin, fibrinogen, haptoglobin, plasminogen) were produced by the liver from day 1. Production of several pig coagulation factors was confirmed. Conclusions After the transplantation of genetically-engineered pig livers into baboons (1) many parameters of hepatic function, including coagulation, were normal or near-normal; (2) there was evidence for production of pig proteins, including coagulation factors, and (3) these appeared to function adequately in baboons, though inter-species compatibility of such proteins remains to be confirmed. PMID:20606605

  4. Potential of the Moringa oleifera saline extract for the treatment of dairy wastewater: application of the response surface methodology.

    PubMed

    Formentini-Schmitt, Dalila Maria; Fagundes-Klen, Márcia Regina; Veit, Márcia Teresinha; Palácio, Soraya Moreno; Trigueros, Daniela Estelita Goes; Bergamasco, Rosangela; Mateus, Gustavo Affonso Pisano

    2018-03-02

    In this work, the coagulation/flocculation/sedimentation treatment of dairy wastewater samples was investigated through serial factorial designs utilizing the saline extract obtained from Moringa oleifera (Moringa) as a coagulant. The sedimentation time (ST), pH, Moringa coagulant (MC) dose and concentration of CaCl 2 have been evaluated through the response surface methodology in order to obtain the ideal turbidity removal (TR) conditions. The empirical quadratic model, in conjunction with the desirability function, demonstrated that it is possible to obtain TRs of 98.35% using a coagulant dose, concentration of CaCl 2 and pH of 280 mg L -1 , 0.8 mol L -1 and 9, respectively. The saline extract from Moringa presented its best efficiency at an alkaline pH, which influenced the reduction of the ST to a value of 25 min. It was verified that the increase in the solubility of the proteins in the Moringa stimulated the reduction of the coagulant content in the reaction medium, and it is related to the use of calcium chloride as an extracting agent of these proteins. The MC proved to be an excellent alternative for the dairy wastewater treatment, compared to the traditional coagulants.

  5. Microcystis aeruginosa-laden water treatment using enhanced coagulation by persulfate/Fe(II), ozone and permanganate: Comparison of the simultaneous and successive oxidant dosing strategy.

    PubMed

    Liu, Bin; Qu, Fangshu; Chen, Wei; Liang, Heng; Wang, Tianyu; Cheng, Xiaoxiang; Yu, Huarong; Li, Guibai; Van der Bruggen, Bart

    2017-11-15

    In this study, the application of enhanced coagulation with persulfate/Fe(II), permanganate and ozone for Microcystis-laden water treatment was investigated. Two oxidant dosage strategies were compared in terms of the organic removal performance: a simultaneous dosing strategy (SiDS) and a successive dosing strategy (SuDS). To optimize the oxidant species, oxidant doses and oxidant dosage strategy, the zeta potential, floc size and dimension fraction, potassium release and organic removal efficiency during the coagulation of algae-laden water were systematically investigated and comprehensively discussed. Ozonation causes most severe cell lysis and reduces organic removal efficiency because it releases intracellular organics. Moreover, ozonation can cause the release of odor compounds such as 2-methylisoborneol (2-MIB) and geosmin (GSM). With increasing doses, the performance of pollutant removal by coagulation enhanced by persulfate/Fe(II) or permanganate did not noticeably improve, which suggests that a low dosage of persulfate/Fe(II) and permanganate is the optimal strategy to enhance coagulation of Microcystis-laden water. The SiDS performs better than the SuDS because more Microcystis cell lysis occurs and less DOC is removed when oxidants are added before the coagulants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Removal of Suspended Solids in Anaerobically Digested Slurries of Livestock and Poultry Manure by Coagulation Using Different Dosages of Polyaluminum Chloride

    NASA Astrophysics Data System (ADS)

    Li, P.; Zhang, C. J.; Zhao, T. K.; Zhong, H.

    2017-01-01

    In this study, anaerobically digested slurries of livestock and poultry manure were pretreated by coagulation-sedimentation using an inorganic polymer coagulant, polyaluminum chloride (PAC). The effect of different PAC dosages on suspended solids (SS) removal and pH in the biogas slurries was assessed to provide reference values for reducing the organic load of biogas slurry in the coagulation-sedimentation process and explore the feasibility of reducing the difficulty in subsequent utilization or processing of biogas slurry. The results showed that for the pig slurry containing approximately 5000 mg/L SS, the removal rate of SS reached up to 81.6% with the coagulant dosage of 0.28 g/L PAC. For the chicken slurry containing approximately 2600 mg/L SS, the removal rate of SS was 30.2% with the coagulant dosage of 0.33 g/L PAC. The removal rate of SS in both slurries of livestock and poultry manure exhibited a downward trend with high PAC dosage. Therefore, there is a need to control the PAC dosage in practical use. The pH changed little in the two types of biogas slurries after treatment with different PAC dosages and both were in line with the standard values specified in the “Standards for Irrigation Water Quality”.

  7. Confinement regulates complex biochemical networks: initiation of blood clotting by "diffusion acting".

    PubMed

    Shen, Feng; Pompano, Rebecca R; Kastrup, Christian J; Ismagilov, Rustem F

    2009-10-21

    This study shows that environmental confinement strongly affects the activation of nonlinear reaction networks, such as blood coagulation (clotting), by small quantities of activators. Blood coagulation is sensitive to the local concentration of soluble activators, initiating only when the activators surpass a threshold concentration, and therefore is regulated by mass transport phenomena such as flow and diffusion. Here, diffusion was limited by decreasing the size of microfluidic chambers, and it was found that microparticles carrying either the classical stimulus, tissue factor, or a bacterial stimulus, Bacillus cereus, initiated coagulation of human platelet-poor plasma only when confined. A simple analytical argument and numerical model were used to describe the mechanism for this phenomenon: confinement causes diffusible activators to accumulate locally and surpass the threshold concentration. To interpret the results, a dimensionless confinement number, Cn, was used to describe whether a stimulus was confined, and a Damköhler number, Da(2), was used to describe whether a subthreshold stimulus could initiate coagulation. In the context of initiation of coagulation by bacteria, this mechanism can be thought of as "diffusion acting", which is distinct from "diffusion sensing". The ability of confinement and diffusion acting to change the outcome of coagulation suggests that confinement should also regulate other biological "on" and "off" processes that are controlled by thresholds.

  8. The Loss of Homeostasis in Hemostasis: New Approaches in Treating and Understanding Acute Disseminated Intravascular Coagulation in Critically Ill Patients*

    PubMed Central

    Abrams, Charles S.

    2012-01-01

    Abstract Disseminated intravascular coagulation (DIC) profoundly increases the morbidity and mortality of patients who have sepsis. Both laboratory and clinical research advanced the understanding of the biology and pathophysiology of DIC. This, in turn, gave rise to improved therapies and patient outcomes. Beginning with a stimulus causing disruption of vascular integrity, cytokines and chemokines cause activation of systemic coagulation and inflammation. Seemingly paradoxically, the interplay between coagulation and inflammation also inhibits endogenous anticoagulants, fibrinolytics, and antiinflammatory pathways. The earliest documented and best‐studied microbial cause of DIC is the lipopolysaccharide endotoxin of Gram‐negative bacteria. Extensive microvascular thrombi emerge in the systemic vasculature due to dysregulation of coagulation. The result of this unrestrained, widespread small vessel thromboses multiorgan system failure. Consumption of platelets and coagulation factors during this process can lead to an elevated risk of hemorrhage. The management of these patients with simultaneous hemorrhage and thrombosis is complex and challenging. Definitive treatment of DIC, and attenuation of end‐organ damage, requires control of the inciting cause. Currently, activated protein C is the only approved therapy in the United States for sepsis complicated by DIC. Further research is needed in this area to improve clinical outcomes for patients with sepsis. Clin Trans Sci 2012; Volume 5: 85–92 PMID:22376264

  9. Removal of arsenic and iron removal from drinking water using coagulation and biological treatment.

    PubMed

    Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah

    2016-02-01

    Effects of biological activated carbon (BAC), biological aerated filter (BAF), alum coagulation and Moringa oleifera coagulation were investigated to remove iron and arsenic contaminants from drinking water. At an initial dose of 5 mg/L, the removal efficiency for arsenic and iron was 63% and 58% respectively using alum, and 47% and 41% respectively using Moringa oleifera. The removal of both contaminants increased with the increase in coagulant dose and decrease in pH. Biological processes were more effective in removing these contaminants than coagulation. Compared to BAF, BAC gave greater removal of both arsenic and iron, removing 85% and 74%, respectively. Longer contact time for both processes could reduce the greater concentration of arsenic and iron contaminants. The addition of coagulation (at 5 mg/L dosage) and a biological process (with 15 or 60 min contact time) could significantly increase removal efficiency, and the maximum removal was observed for the combination of alum and BAC treatment (60 min contact time), with 100% and 98.56% for arsenic and iron respectively. The reduction efficiency of arsenic and iron reduced with the increase in the concentration of dissolved organics in the feedwater due to the adsorption competition between organic molecules and heavy metals.

  10. Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios

    Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less

  11. Coagulation effectiveness of graphene oxide for the removal of turbidity from raw surface water.

    PubMed

    Aboubaraka, Abdelmeguid E; Aboelfetoh, Eman F; Ebeid, El-Zeiny M

    2017-08-01

    This study presents the performance of graphene oxide (GO) as a coagulant in turbidity removal from naturally and artificially turbid raw surface water. GO is considered an excellent alternative to alum, the more common coagulant used in water treatment processes, to reduce the environmental release of aluminum. Effects of GO dosage, pH, and temperature on its coagulation ability were studied to determine the ideal turbidity removal conditions. The turbidity removal was ≥95% for all levels of turbid raw surface water (20, 100, and 200 NTU) at optimum conditions. The role of alkalinity in inducing turbidity removal by GO coagulation was much more pronounced upon using raw surface water samples compared with that using artificially turbid deionized water samples. Moreover, GO demonstrated high-performance removal of biological contaminants such as algae, heterotrophic bacteria, and fecal coliform bacteria by 99.0%, 98.8% and 96.0%, respectively, at a dosage of 40 mg/L. Concerning the possible environmental release of GO into the treated water following filtration process, there was no residual GO in a wide range of pH values. The outcomes of the study highlight the excellent coagulation performance of GO for the removal of turbidity and biological contaminants from raw surface water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Removal of acetaminophen and naproxen by combined coagulation and adsorption using biochar: influence of combined sewer overflow components.

    PubMed

    Jung, Chanil; Oh, Jeill; Yoon, Yeomin

    2015-07-01

    The combined coagulation and adsorption of targeted acetaminophen and naproxen using activated biochar and aluminum sulfate were studied under various synthetic "combined sewer overflow" (CSO) conditions. The biochar demonstrated better adsorption performance for both acetaminophen and naproxen (removal, 94.1 and 97.7%, respectively) than that of commercially available powdered activated carbon (removal, 81.6 and 94.1%, respectively) due to superior carbonaceous structure and surface properties examined by nuclear magnetic resonance analysis. The adsorption of naproxen was more favorable, occupying active adsorption sites on the adsorbents by naproxen due to its higher adsorption affinity compared to acetaminophen. Three classified CSO components (i.e., representing hydrophobic organics, hydrophilic organics, and inorganics) played different roles in the adsorption of both adsorbates, resulted in inhibition by humic acid complexation or metal ligands and negative electrostatic repulsion under adsorption and coagulation combined system. Adsorption alone with biochar was determined to be the most effective adsorptive condition for the removal of both acetaminophen and naproxen under various CSO conditions, while both coagulation alone and combined adsorption and coagulation failed to remove the acetaminophen and naproxen adequately due to an increase in ionic strength in the presence of spiked aluminum species derived from the coagulant.

  13. Elastic scattering spectroscopy of coagulated brain tissues

    NASA Astrophysics Data System (ADS)

    Ateş, Filiz; Tabakoğlu, Haşim Özgür; Bozkulak, Özgüncem; Canpolat, Murat; Gülsoy, Murat

    2006-02-01

    The goal of this study was to differentiate the parts of lamb brain according to elastic scattering spectroscopy and detect the optical alterations due to coagulation. Cells and tissues are not uniform and have complex structures and shapes. They can be referred to as scattering particles. The process of scattering depends on the light wavelength and on the scattering medium properties; especially on the size and the density of the medium. When elastic scattering spectroscopy (ESS) is employed, the morphological alterations of tissues can be detected using spectral measurements of the elastic scattered light over a wide range of wavelengths. In this study firstly, the slopes of ESS spectra were used to differentiate the parts of lamb brains (brainstem, cerebellum, gray matter, white matter) in vitro in the range of 450 - 750 nm. Secondly, tissues were coagulated at different temperatures (45, 60, and 80 °C) and ESS spectra were taken from native and coagulated tissues. It was observed that as the coagulation temperature increased, the slope of the elastic scattering spectra decreased. Thus, optical properties of tissues were changed with respect to the change in nuclear to cytoplasmic ratio due to the water loss. Results showed that the slopes of ESS spectra in the visible range revealed valuable information about the morphological changes caused by coagulation.

  14. Incorporating radioactive decay into charging and coagulation of multicomponent radioactive aerosols

    DOE PAGES

    Kim, Yong-ha; Yiacoumi, Sotira; Nenes, Athanasios; ...

    2017-09-29

    Compositional changes by the decay of radionuclides in radioactive aerosols can influence their charging state, coagulation frequency and size distribution throughout their atmospheric lifetime. The importance of such effects is unknown as they have not been considered in microphysical and global radioactivity transport studies to date. Here, we explore the effects of compositional changes on the charging efficiency and coagulation rates of aerosols using a set of kinetic equations that couple all relevant processes (decay, charging and coagulation) and their evolution over time. Compared to a coupled aggregation-tracer model for the prediction of the radioactive composition of particulates undergoing coagulation,more » our kinetic approach can provide similar results using much less central processing unit time. Altogether with other considerations, our approach is computational efficient enough to allow implementation in 3D atmospheric transport models. The decay of radionuclides and the production of decay products within radioactive aerosols may significantly affect the aerosol charging rates, and either hinder or promote the coagulation of multicomponent radioactive aerosols. Our results suggest that radiological phenomena occurring within radioactive aerosols, as well as subsequent effects on aerosol microphysics, should be considered in regional and global models to more accurately predict radioactivity transport in the atmosphere in case of a nuclear plant accident.« less

  15. A parametric comparative study of electrocoagulation and coagulation using ultrafine quartz suspensions.

    PubMed

    Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde

    2009-11-15

    This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.

  16. Oxidation and coagulation of humic substances by potassium ferrate.

    PubMed

    Graham, N J D; Khoi, T T; Jiang, J-Q

    2010-01-01

    Ferrate (FeO₄²⁻) is believed to have a dual role in water treatment, both as oxidant and coagulant. Few studies have considered the coagulation effect in detail, mainly because of the difficulty of separating the oxidation and coagulation effects. This paper summarises some preliminary results from laboratory-based experiments that are investigating the coagulation reaction dynamically via a PDA instrument, between ferrate and humic acid (HA) at different doses and pH values, and comparing the observations with the use of ferric chloride. The PDA output gives a comparative measure of the rate of floc growth and the magnitude of floc formation. The results of the tests show some significant differences in the pattern of behaviour between ferrate and ferric chloride. At pH 5 the chemical dose range (as Fe) corresponding to HA coagulation was much broader for ferrate than ferric chloride, and the optimal Fe dose was greater. Ferrate oxidation appears to increase the hydrophilic and electronegative nature of the HA leading to an extended region of charge neutralisation. A consequence of the ferrate oxidation is that the extent of HA removal was slightly lower ( approximately 5%) than with ferric chloride. At pH 7, in the sweep flocculation domain, ferrate achieved much greater floc formation than ferric chloride, but a substantially lower degree of HA removal.

  17. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment.

    PubMed

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Günther, Rolf W; Mahnken, Andreas H

    2010-08-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 +/- 1.1 mm (5 W), 6.0 +/- 2.0 mm (10 W) and 5.2 +/- 0.51 mm (20 W) in liver and 5.0 +/- 0.7 mm (5 W), 6.6 +/- 0.9 (10 W) and 6.0 +/- 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 +/- 4.6 mm (10 W) in liver and 6.0 +/- 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 +/- 4.4 mm in kidney and 11.1 +/- 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy.

  18. Thymoquinone Modulates Blood Coagulation in Vitro via Its Effects on Inflammatory and Coagulation Pathways

    PubMed Central

    Muralidharan-Chari, Vandhana; Kim, Jaehan; Abuawad, Ahlam; Naeem, Mubeena; Cui, Huadong; Mousa, Shaker A.

    2016-01-01

    Thymoquinone (THQ) is a major component of black seeds. Given that both THQ and black seeds exhibit anti-cancer and anti-inflammatory activities, we hypothesized that THQ will affect cancer-associated thrombosis (CAT), which is primarily triggered by tissue factor (TF) and inflammation. The effect of both black seed-extracted and purchased (“pure”) THQ on normal blood coagulation was tested with in vitro thromboelastography (TEG) and activated partial thromboplastin time (aPTT) coagulation assays. The effect of pure THQ on CAT was tested with aPTT assay using pancreatic cancer cell lines that are either positive or negative for TF, and with TEG assay using lipopolysaccharide as an inflammatory trigger. Additionally, the direct effect of THQ on the inactivation of factors IIa and Xa was assessed. Since TNF-α facilitates crosstalk between inflammation and thrombosis by triggering the NF-κB pathway, we tested THQ’s ability to interfere with this communication with a luciferase assay. Both extracted and pure THQ had minimal effects on normal blood coagulation. Pure THQ reversed CAT initiated by both TF and inflammation to basal levels (p < 0.001). Mechanistically, while THQ had minimal to no effect on factor IIa and Xa inactivation, it strongly reduced the effects of TNF-α on NF-κB elements (p < 0.001). THQ has a minimal effect on basal coagulation and can reverse CAT in vitro, possibly by interfering with the crosstalk between inflammation and coagulation. This study suggests the utility of THQ as a preventative anticoagulant and/or as a supplement to existing chemotherapies and anticoagulant therapies. PMID:27043539

  19. Comparison of 808, 980, and 1075nm lasers for noninvasive thermal coagulation of the canine vas deferens, ex vivo

    NASA Astrophysics Data System (ADS)

    Cilip, Christopher M.; Schweinsberger, Gino R.; Fried, Nathaniel M.

    2011-03-01

    Successful noninvasive laser coagulation of the canine vas deferens, in vivo, has been previously reported. However, the therapeutic window for treatment is relatively narrow. This study determines the dependence of vas thermal coagulation on laser wavelength for development of a noninvasive laser vasectomy procedure. Noninvasive laser coagulation of canine vas tissue, ex vivo, was performed using three commonly available near-infrared laser wavelengths: 808, 980, and 1075 nm. Each laser delivered an average power of 9.2 W, 500-ms pulse duration, pulse rate of 1.0-Hz, and 3.2-mm diameter laser spot, synchronized with cryogen spray cooling of the scrotal skin surface for a total treatment time of 60 s. Vas burst pressures were measured to determine strength of vas closure and compared to previously reported ejaculation pressures. Gross inspection of vas and scrotal skin was also performed immediately after the procedure as an indicator of thermal coagulation and skin burns. The 1075 nm laser produced the highest vas burst pressures (288 +/- 28 mmHg), significantly greater than previously reported ejaculation pressures (136 +/- 29 mmHg). The 808 nm wavelength produced insufficient vas burst pressures of 141 +/- 61 mmHg, and minor scrotal skin burns were observed in at least one case. The 980 nm wavelength was unable to produce thermal coagulation of the vas, with low burst pressures (89 +/- 58 mmHg) and severe scrotal skin burns. The 1075 nm wavelength was the only near-IR wavelength that consistently thermally coagulated the vas with a strong degree of closure and without any scrotal skin burns.

  20. Impact of organic polyelectrolytes on coagulation of source-separated black water.

    PubMed

    Kozminykh, Pavlo; Heistad, Arve; Ratnaweera, Harsha C; Todt, Daniel

    2016-01-01

    Household wastewater is originated from common people's activities and has a potential harmful impact on the environment if discharged directly without proper treatment. Toilet wastewater or black water (BW) contains urine, faeces, toilet paper and flushing water and it contains the majority of pollutants obtained from a single household. In this study, the focus was on BW treatment using chemical methods. The main goal of current research was to define the possibility and applicability of conventional coagulants and flocculants in direct chemical treatment of vacuum-collected BW to remove particles, organic matter and phosphorous. After the definition of dosing ranges, based on the equivalent doses in conventional municipal and industrial wastewater treatment data, aluminium and iron coagulants, organic polyelectrolytes (polymers with anionic, neutral and cationic charge with different molecular weights) and their various combinations were tested using the well-known jar-test laboratory method to study aggregation and solid-liquid separation processes in raw BW. The most important process parameter during the coagulation was pH level, dependent on the type and doses of metal salts. Some side processes were found to occur while using iron-based coagulants. Dosing of either single coagulants or single polymers did not give satisfactory results, while a combination of aluminium salts and cationic polymers showed high removal rates in total suspended solids, total chemical oxygen demand and ortho-phosphates, reaching 97.8%, 92% and 98.6%, respectively, with the optimal doses of chemicals. Cationic polymers with the lowest molecular weight and highest charge density were the most efficient in combination with aluminium coagulants.

  1. Evaluation of the treatment of reverse osmosis concentrates from municipal wastewater reclamation by coagulation and granular activated carbon adsorption.

    PubMed

    Sun, Ying-Xue; Yang, Zhe; Ye, Tao; Shi, Na; Tian, Yuan

    2016-07-01

    Reverse osmosis concentrate (ROC) from municipal wastewater reclamation reverse osmosis (mWRRO) contains elevated concentrations of contaminants which pose potential risks to aquatic environment. The treatment of ROC from an mWRRO using granular activated carbon (GAC) combined pretreatment of coagulation was optimized and evaluated. Among the three coagulants tested, ferric chloride (FeCl3) presented relatively higher DOC removal efficiency than polyaluminium chloride and lime at the same dosage and coagulation conditions. The removal efficiency of DOC, genotoxicity, and antiestrogenic activity concentration of the ROC could achieve 16.9, 18.9, and 39.7 %, respectively, by FeCl3 coagulation (with FeCl3 dosage of 180.22 mg/L), which can hardly reduce UV254 and genotoxicity normalized by DOC of the DOM with MW <5 kDa. However, the post-GAC adsorption column (with filtration velocity of 5.7 m/h, breakthrough point adsorption capacity of 0.22 mg DOC/g GAC) exhibited excellent removal efficiency on the dominant DOM fraction of MW <5 kDa in the ROC. The removal efficiency of DOC, UV254, and TDS in the ROC was up to 91.8, 96, and 76.5 %, respectively, by the FeCl3 coagulation and post-GAC adsorption. Also, the DOM with both genotoxicity and antiestrogenic activity were completely eliminated by the GAC adsorption. The results suggest that GAC adsorption combined pretreatment of FeCl3 coagulation as an efficient method to control organics, genotoxicity, and antiestrogenic activity in the ROC from mWRRO system.

  2. Anxiety and depression in patients three months after myocardial infarction: Association with markers of coagulation and the relevance of age.

    PubMed

    Geiser, Franziska; Urbach, Anne Sarah; Harbrecht, Ursula; Conrad, Rupert; Pötzsch, Bernd; Amann, Nele; Kiesewetter, Katharina; Sieke, Alexandra; Wolffs, Kyra; Skowasch, Dirk

    2017-08-01

    Anxiety and depression are associated with an activation of coagulation and an impairment of fibrinolysis, which may contribute to the increased cardiovascular risk associated with the two disorders. However, very few studies have examined the impact of psychological distress on coagulation factors in coronary artery disease patients. The aim of this study was to assess the correlation between anxiety/depression and factors of coagulation and fibrinolysis in patients who had suffered an acute MI three months prior. In 148 patients, anxiety and depression were assessed by the Hospital Anxiety and Depression Scale (HADS) shortly after MI and three months later. At the second time of assessment, plasma levels of fibrinogen, factor VII, factor VIII, von Willebrand factor, prothrombin-fragment 1 and 2, tissue-plasminogen-activator, plasminogen activator inhibitor-1, D-dimer, and homocysteine were measured. In 32% of the patients, elevated levels of anxiety and depression were found three months after a MI. Multiple regression analyses showed that coagulation and fibrinolysis markers were not significantly associated with HADS anxiety and depression scores. We found that age, gender, BMI, and smoking status were significant predictors for haemostasis factors. A higher age was associated with a higher coagulability but lower anxiety levels. We measured parameters of coagulation and fibrinolysis in patients three months after MI and found no predictive value of HADS anxiety and depression scores shortly after MI or at the time of blood sampling. The effects of age on the relationship between anxiety and haemostasis should be further investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Endoscopic hemostasis for peptic ulcer bleeding: systematic review and meta-analyses of randomized controlled trials.

    PubMed

    Baracat, Felipe; Moura, Eduardo; Bernardo, Wanderley; Pu, Leonardo Zorron; Mendonça, Ernesto; Moura, Diogo; Baracat, Renato; Ide, Edson

    2016-06-01

    Peptic ulcer represents the most common cause of upper gastrointestinal bleeding. Endoscopic therapy can reduce the risks of rebleeding, continued bleeding, need for surgery, and mortality. The objective of this review is to compare the different modalities of endoscopic therapy. Studies were identified by searching electronic databases MEDLINE, Embase, Cochrane, LILACS, DARE, and CINAHL. We selected randomized clinical trials that assessed contemporary endoscopic hemostatic techniques. The outcomes evaluated were: initial hemostasis, rebleeding rate, need for surgery, and mortality. The possibility of publication bias was evaluated by funnel plots. An additional analysis was made, including only the higher-quality trials. Twenty-eight trials involving 2988 patients were evaluated. Injection therapy alone was inferior to injection therapy with hemoclip and with thermal coagulation when evaluating rebleeding and the need for emergency surgery. Hemoclip was superior to injection therapy in terms of rebleeding; there were no statistically significant differences between hemoclip alone and hemoclip with injection therapy. There was considerable heterogeneity in the comparisons between hemoclip and thermal coagulation. There were no statistically significant differences between thermal coagulation and injection therapy, though their combination was superior, in terms of rebleeding, to thermal coagulation alone. Injection therapy should not be used alone. Hemoclip is superior to injection therapy, and combining hemoclip with an injectate does not improve hemostatic efficacy above hemoclip alone. Thermal coagulation has similar efficacy as injection therapy; combining these appears to be superior to thermal coagulation alone. Therefore, we recommend the application of hemoclips or the combined use of injection therapy with thermal coagulation for the treatment of peptic ulcer bleeding.

  4. Partial nephrectomy using radiofrequency incremental bipolar generator with multi electrode probe: experimental study in bench pig kidneys

    PubMed Central

    2014-01-01

    Background The aim of this research project was the realization of an incremental bipolar radiofrequency generator with inline 4-electrode probe for partial renal resection without clamping of the vessels. Methods The experimentation was carried out across two phases: the preliminary realization of a specific generator and an inline multielectrode probe for open surgery (Phase 1); system testing on 27 bench kidneys for a total of 47 partial resection (Phase 2). The parameters evaluated were: power level, generator automatisms, parenchymal coagulation times, needle caliber, thickness of the coagulated tissue “slice”, charring, ergonomy, feasibility of the application of “bolster” stitches. Results The analysis of the results referred to the homogeneity and thickness of coagulation, energy supply times with reference to the power level and caliber of the needles. The optimal results were obtained by using needles of 1.5 mm caliber at power level 5, and with coagulation times of 54 seconds for the first insertion and 30 seconds for the second. Conclusions The experimentation demonstrated that the apparatus, consisting of a generator named “LaparoNewPro” and fitted with a dedicated probe for open surgery, is able to carry out a coagulation of the line of resection of the renal parenchyma in a homogeneous manner, in short times, without tissue charring, and with the possibility of stitching both on coagulated tissue and the caliceal system. The generator automatism based on the flow of the current supplied by each electrode is reliable, and the cessation of energy supply coincides with optimal coagulation. PMID:24410789

  5. Analysis of aggregation of platelets in thrombosis

    NASA Astrophysics Data System (ADS)

    Ahuja, Suresh

    Platelets are key players in thrombus formation by first rolling over collagen bound von Willebrand factor followed by formation of a stable interaction with collagen. The first adhered platelets bind additional platelets until the whole injury is sealed off by a platelet aggregate. The coagulation system stabilizes the formed platelet plug by creating a tight fibrin network, and then wound contraction takes place because of morphological changes in platelets. Coagulation takes place by platelet activation and aggregation mainly through fibrinogen polymerization into fibrin fibers. The process includes multiple factors, such as thrombin, plasmin, and local shear-rate which regulate and control the process. Coagulation can be divided into two pathways: the intrinsic pathway and the extrinsic pathway. The intrinsic pathway is initiated by the exposure of a negatively charged. It is able to activate factor XII, using a complex reaction that includes prekallikrein and high-molecular-weight kininogen as cofactors.. Thrombin is the final enzyme that is needed to convert fibrinogen into fibrin. The extrinsic pathway starts with the exposure of tissue factor to the circulating blood, which is the major initiator of coagulation. There are several feedback loops that reinforce the coagulation cascade, resulting in large amounts of thrombin. It is dependent on the presence of pro-coagulant surfaces of cells expressing negatively charged phospholipids--which include phosphatidylserine (PS)--on their outer membrane. PS-bearing surfaces are able to increase the efficiency of the reactions by concentrating and co-localizing coagulation factors.. Aggregation of platelets are analyzed and compared to adhesion of platelet to erythrocyte and to endothelial cells. This abstract is replacing MAR16-2015-020003.

  6. [Endothelial microparticles (EMP) in physiology and pathology].

    PubMed

    Sierko, Ewa; Sokół, Monika; Wojtukiewicz, Marek Z

    2015-08-18

    Endothelial microparticles (EMP) are released from endothelial cells (ECs) in the process of activation and/or apoptosis. They harbor adhesive molecules, enzymes, receptors and cytoplasmic structures and express a wide range of various constitutive antigens, typical for ECs, at their surface. Under physiological conditions the concentration of EMP in the blood is clinically insignificant. However, it was reported that under pathological conditions EMP concentration in the blood might slightly increase and contribute to blood coagulation, angiogenesis and inflammation. It has been shown that EMP directly and indirectly contribute to the activation of blood coagulation. Endothelial microparticles directly participate in blood coagulation through their surface tissue factor (TF) - a major initiator of blood coagulation. Furthermore, EMP exhibit procoagulant potential via expression of negatively charged phospholipids at their surface, which may promote assembly of coagulation enzymes (TF/VII, tenases and prothrombinase complexes), leading to thrombus formation. In addition, they provide a binding surface for coagulation factors: IXa, VIII, Va and IIa. Moreover, it is possible that EMP transfer TF from TF-bearing EMP to activated platelets and monocytes by binding them through adhesion molecules. Also, EMP express von Willebrand factor, which may facilitate platelet aggregation. Apart from their procoagulant properties, it was demonstrated that EMP may express adhesive molecules and metalloproteinases (MMP-2, MMP-9) at their surface and release growth factors, which may contribute to angiogenesis. Additionally, surface presence of C3 and C4 - components of the classical pathway - suggests pro-inflammatory properties of these structures. This article contains a summary of available data on the biology and pathophysiology of endothelial microparticles and their potential role in blood coagulation, angiogenesis and inflammation.

  7. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation.

    PubMed

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua; Gao, Fei; Zou, Ru-hai; Zhang, Tian-qi

    2016-04-01

    To compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model. 30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups. Temperature-time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm(3)) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm(3), P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times. HAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.

  8. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion: A case report.

    PubMed

    Kim, Ji Hong; Kang, Min Ho; Seong, Mincheol; Cho, Heeyoon; Shin, Yong Un

    2018-04-01

    Non-arteritic anterior ischemic optic neuropathy (NAION) is characterized by sudden, painless visual loss and optic disc edema. NAION occurs mainly in the presence of cardiovascular disease and hypercoagulability, mainly in patients over 50 years of age. We experienced a case of NAION associated with central retinal vein occlusion (CRVO) in a young man with no underlying disease. A 46-year-old man was referred to our clinic following a sudden loss of vision in his right eye. The patient exhibited no underlying disease and reported no ongoing medication. Significant visual loss and visual disturbance of the right eye were observed. The pupil of the right eye was enlarged and an afferent pupillary defect was observed. On fundus examination, retinal hemorrhage was observed in the peripheral retina; macular edema was observed in optical coherence tomography analysis. However, optic disc edema was not evident. No abnormal findings were found in routine blood tests for hypercoagulability. After 3 days of steroid intravenous injection, macular edema disappeared and visual acuity was improved, but optic disc edema began to appear. One week later, optic disc edema was evident and visual acuity was significantly reduced; thus, the patient was diagnosed with NAION. In fluorescein angiography, peripheral retinal ischemia was observed, suggesting that CRVO was complicated. Blood tests, including analysis of coagulation factors, were performed again, showing that coagulation factors IX and XI were increased. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion. Systemic steroids were administered. One month later, optic disc edema and retinal hemorrhage gradually diminished and eventually disappeared; however, visual acuity did not recover. In young patients without underlying disease, cases of NAION require careful screening for coagulation disorders. Even if there is no abnormality in the test for routine coagulation status, it may be necessary to confirm a coagulation defect through an additional coagulation factor assay.

  9. The effect of corn trypsin inhibitor and inhibiting antibodies for FXIa and FXIIa on coagulation of plasma and whole blood.

    PubMed

    Hansson, K M; Nielsen, S; Elg, M; Deinum, J

    2014-10-01

    Corn trypsin inhibitor (CTI), an inhibitor of FXIIa, is used to prevent plasma coagulation by contact activation, to specifically investigate tissue factor (TF)-initiated coagulation. In the present work the specificity of CTI for factor (F) XIIa is questioned. In the commercial available plasma coagulation assays CTI was found to double activated partial thromboplastin time (APTT) at a plasma concentration of 7.3 ± 1.5 μm CTI (assay concentration 2.4 μm). No effect was found on the prothrombin time (PT) when high TF concentrations were used. Also, with specific antibodies for FXIIa and for FXIa only APTT was found to be extended but not PT. With specific enzyme assays using chromogenic substrates CTI was shown to be a strong inhibitor of FXIIa and a competitive inhibitor of FXIa with Ki  = 8.1 ± 0.3 μm, without effect on the coagulation factors FVIIa, FIXa, FXa and thrombin. In thrombin generation and coagulation (free oscillation rheometry, FOR) assays, initiated with low TF concentrations, no effect of CTI (plasma concentrations of 4.4 and 13.6 μm CTI, 25 resp. 100 mg L(-1) in blood) was found with ≥ 1 pm TF. At ≤ 0.1 pm TF in the FOR whole blood assay the coagulation time (CT) concentration dependently increased while the plasma CT became longer than the observation time. To avoid inhibition of FXIa and the thrombin feedback loop we recommend that for coagulation assays the concentration of CTI in blood should be below 20 mg L(-1) (1.6 μm) and in plasma below 3 μm. © 2014 International Society on Thrombosis and Haemostasis.

  10. Determination of dabigatran, rivaroxaban and apixaban by ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) and coagulation assays for therapy monitoring of novel direct oral anticoagulants.

    PubMed

    Schmitz, E M H; Boonen, K; van den Heuvel, D J A; van Dongen, J L J; Schellings, M W M; Emmen, J M A; van der Graaf, F; Brunsveld, L; van de Kerkhof, D

    2014-10-01

    Three novel direct oral anticoagulants (DOACs) have recently been registered by the Food and Drug Administration and European Medicines Agency Commission: dabigatran, rivaroxaban, and apixaban. To quantify DOACs in plasma, various dedicated coagulation assays have been developed. To develop and validate a reference ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) method and to evaluate the analytical performance of several coagulation assays for quantification of dabigatran, rivaroxaban, and apixaban. The developed UPLC-MS/MS method was validated by determination of precision, accuracy, specificity, matrix effects, lower limits of detection, carry-over, recovery, stability, and robustness. The following coagulation assays were evaluated for accuracy and precision: laboratory-developed (LD) diluted thrombin time (dTT), Hemoclot dTT, Pefakit PiCT, ECA, Liquid anti-Xa, Biophen Heparin (LRT), and Biophen DiXal anti-Xa. Agreement between the various coagulation assays and UPLC-MS/MS was determined with random samples from patients using dabigatran or rivaroxaban. The UPLC-MS/MS method was shown to be accurate, precise, sensitive, stable, and robust. The dabigatran coagulation assay showing the best precision, accuracy and agreement with the UPLC-MS/MS method was the LD dTT test. For rivaroxaban, the anti-factor Xa assays were superior to the PiCT-Xa assay with regard to precision, accuracy, and agreement with the reference method. For apixaban, the Liquid anti-Xa assay was superior to the PiCT-Xa assay. Statistically significant differences were observed between the various coagulation assays as compared with the UPLC-MS/MS reference method. It is currently unknown whether these differences are clinically relevant. When DOACs are quantified with coagulation assays, comparison with a reference method as part of proficiency testing is therefore pivotal. © 2014 International Society on Thrombosis and Haemostasis.

  11. Quasi-static acoustic tweezing thromboelastometry.

    PubMed

    Holt, R G; Luo, D; Gruver, N; Khismatullin, D B

    2017-07-01

    Essentials Blood coagulation measurement during contact with an artificial surface leads to unreliable data. Acoustic tweezing thromboelastometry is a novel non-contact method for coagulation monitoring. This method detects differences in the blood coagulation state within 10 min. Coagulation data were obtained using a much smaller sample volume (4 μL) than currently used. Background Thromboelastography is widely used as a tool to assess the coagulation status of critical care patients. It allows observation of changes in material properties of whole blood, beginning with early stages of clot formation and ending with clot lysis. However, the contact activation of the coagulation cascade at surfaces of thromboelastographic systems leads to inherent variability and unreliability in predicting bleeding or thrombosis risks. Objectives To develop acoustic tweezing thromboelastometry as a non-contact method for perioperative assessment of blood coagulation. Methods Acoustic tweezing is used to levitate microliter drops of biopolymer and human blood samples. By quasi-statically changing the acoustic pressure we control the sample drop location and deformation. Sample size, deformation and location are determined by digital imaging at each pressure. Results Simple Newtonian liquid solutions maintain a constant, reversible location vs. deformation curve. In contrast, the location/deformation curves for gelatin, alginate, whole blood and blood plasma uniquely change as the samples solidify. Increasing elasticity causes the sample to deform less, leading to steeper stress/strain curves. By extracting a linear regime slope, we show that whole blood or blood plasma exhibits a unique slope profile as it begins to clot. By exposing blood samples to pro- or antithrombotic agents, the slope profile changes, allowing detection of hyper- or hypocoagulable states. Conclusions We demonstrate that quasi-static acoustic tweezing can yield information about clotting onset, maturation and strength. The advantages of small sample size, non-contact and rapid measurement make this technique desirable for real-time monitoring of blood coagulation. © 2017 International Society on Thrombosis and Haemostasis.

  12. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.

    PubMed

    Birschmann, Ingvild; Dittrich, Marcus; Eller, Thomas; Wiegmann, Bettina; Reininger, Armin J; Budde, Ulrich; Strüber, Martin

    2014-01-01

    Thromboembolic and bleeding events in patients with a left ventricular assist device (LVAD) are still a major cause of complications. Therefore, the balance between anti-coagulant and pro-coagulant factors needs to be tightly controlled. The principle hypothesis of this study is that different pump designs may have an effect on hemolysis and activation of the coagulation system. Referring to this, the HeartMate II (HMII; Thoratec Corp, Pleasanton, CA) and the HeartWare HVAD (HeartWare International Inc, Framingham, MA) were investigated. For 20 patients with LVAD support (n = 10 each), plasma coagulation, full blood count, and clinical chemistry parameters were measured. Platelet function was monitored using platelet aggregometry, platelet function analyzer-100 system ( Siemens, Marburg, Germany), vasodilator-stimulated phosphoprotein phosphorylation assay, immature platelet fraction, platelet-derived microparticles, and von Willebrand diagnostic. Acquired von Willebrand syndrome could be detected in all patients. Signs of hemolysis, as measured by lactate dehydrogenase levels (mean, 470 U/liter HMII, 250 U/liter HVAD; p < 0.001), were more pronounced in the HMII patients. In contrast, D-dimer analysis indicated a significantly higher activation of the coagulation system in HVAD patients (mean, 0.94 mg/liter HMII, 2.01 mg/liter HVAD; p < 0.01). The efficacy of anti-platelet therapy using clopidogrel was not sufficient in more than 50% of the patients. Our results support the finding that all patients with rotary blood pumps suffered from von Willebrand syndrome. In addition, a distinct footprint of effects on hemolysis and the coagulation system can be attributed to different devices. As a consequence, the individual status of the coagulation system needs to be controlled in long-term patients. © 2013 Published by International Society for the Heart and Lung Transplantation on behalf of International Society for Heart and Lung Transplantation.

  13. A data-driven approach for the study of coagulation phenomena in waste lubricant oils and its relevance in alkaline regeneration treatments.

    PubMed

    Pinheiro, C T; Ascensão, V R; Reis, M S; Quina, M J; Gando-Ferreira, L M

    2017-12-01

    Coagulation phenomena can occur in certain types of waste lubricant oils (WLO) during regeneration processes involving alkaline treatments, causing plant shutdowns. In this context, this study addresses the nature of the compounds responsible for the coagulation phenomena after the alkaline treatment. For such, an empirical test was developed to assess the coagulation behaviour of WLO, consisting in the addition of KOH to the WLO followed by heating under stirring conditions. This test was performed on 133 samples and four coagulation classes were identified: A; B1; B2 and C. Moreover, a physicochemical characterization of WLO was carried out regarding viscosity at 40°C, saponification number (SN), total acid number (TAN), surface tension, water content, elemental analysis and functional groups (FTIR). 56 samples of fresh lubricant oils for different applications were also characterized and their properties assessed and compared. Multivariate methods were applied to WLO to discriminate among coagulation classes based on FTIR spectra. It was found that coagulation classes A and B1 exhibit statistically similar patterns for all properties determined. Spectral discriminating analysis did not reveal discriminant peaks for class B1 samples, and the presence of specific additives was pointed as the possible factor underlying the increase in viscosity in this oils. Class B2 presents the absence of additives and oxidation products as differentiating features. In addition, B2 samples showed lower TAN SN, and lower concentration of some elements. Lubricants from gear or hydraulic applications can give rise to this class of WLO. Oils of Class C are mainly composed by synthetic ester type base oils, which hamper regeneration processes using alkaline pretreatments. In future studies, WLO type A and B1 can be classified as a single class. The coagulation phenomena classification becomes A - negative, B - precipitate formation and C - positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. [The use of thrombelastography in evaluation of coagulation in females with physiological or pathological gravidity].

    PubMed

    Polák, F; Lips, M; Bedrichová, H; Kríz, P; Parízek, A

    2007-01-01

    During gravidity changes in coagulation develop, however different norms for pregnant women and prevailing population are rarely used. Pathological gravidity can be accompanied with more significant coagulopathies. Thrombelastography is more and more frequently used for evaluation of coagulation parameters of pregnant women. The aim of the study was to compare thrombelastographic coagulation parameters in females with physiological or pathological gravidity and with norms for prevailing population. 60 women in the 3rd trimester of physiological gravidity (group ZDRAVE) and 50 women with pathological gravidity (women with preeclampsia or with a dead fetus, group PATOL) were examined. Both groups were of the comparable age. Average values of studied parameters in the group ZDRAVE were found at the level of "procoagulation" limits for prevailing population. In the group PATOL, average values were even more "procoagulative", however, differences to the ZDRAVE group were nor significant: time r 4.7 (SD 1.7) vs. 4.4 (SD 2.0) p = 0.461 (norm for prevailing population 4-8 min), time to 1.5 (0.5) vs. 1.3 (0.4) p = 0.030 (norm 1-4 min), angle alpha 69.6 (5.5) vs. 71.0 (7.7) p = 0.324 (norm 47-74 degrees), maximal amplitude 71.3 (4.5) vs. 73.1 (4.7) p = 0.079 (norm 55-73 mm), coagulation index 2.7 (1.8) vs. 3.2 (1.8) p = 0.219 (norm (-3)-(+3)). In the group PATOL higher variability than in the group ZDRAVE was found. On the basis of the group ZDRAVE selection percentiles, new norms of thrombelastographic coagulation parameters for pregnant women were elaborated. Coagulation during pregnancy differs significantly from that of prevailing population. That is why the new thrombelastographic norms for pregnant women are submitted. Coagulation changes in pathological pregnancies are more difficult to anticipate than in healthy gestations.

  15. Investigating the characteristic strength of flocs formed from crude and purified Hibiscus extracts in water treatment.

    PubMed

    Jones, Alfred Ndahi; Bridgeman, John

    2016-10-15

    The growth, breakage and re-growth of flocs formed using crude and purified seed extracts of Okra (OK), Sabdariffa (SB) and Kenaf (KE) as coagulants and coagulant aids was assessed. The results showed floc size increased from 300 μm when aluminium sulphate (AS) was used as a coagulant to between 696 μm and 722 μm with the addition of 50 mg/l of OK, KE and SB crude samples as coagulant aids. Similarly, an increase in floc size was observed when each of the purified proteins was used as coagulant aid at doses of between 0.123 and 0.74 mg/l. The largest floc sizes of 741 μm, 460 μm and 571 μm were obtained with a 0.123 mg/l dose of purified Okra protein (POP), purified Sabdariffa (PSP) and purified Kenaf (PKP) respectively. Further coagulant aid addition from 0.123 to 0.74 mg/l resulted in a decrease in floc size and strength in POP and PSP. However, an increase in floc strength and reduced d50 size was observed in PKP at a dose of 0.74 mg/l. Flocs produced when using purified and crude extract samples as coagulant aids exhibited high recovery factors and strength. However, flocs exhibited greater recovery post-breakage when the extracts were used as a primary coagulant. It was observed that the combination of purified proteins and AS improved floc size, strength and recovery factors. Therefore, the applications of Hibiscus seeds in either crude or purified form increases floc growth, strength, recoverability and can also reduce the cost associated with the import of AS in developing countries. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  16. Microalgae removal with Moringa oleifera.

    PubMed

    Barrado-Moreno, M M; Beltran-Heredia, J; Martín-Gallardo, J

    2016-02-01

    Moringa oleifera seed extract was tested for algae (Chlorella, Microcystis, Oocystis and Scenedesmus) removal by Jar-test technique. This coagulant can be used in drinking water treatment. Jar-test has been carried out in order to evaluate the efficiency of this natural coagulant agent inside real surface water matrix. The influence of variables has been studied in this process, including operating parameters such as coagulant dosage, initial algae concentration, pH, agitation time and water matrix. Removal capacity is verified for water with high contamination of algae while the process is not affected by the pH and water matrix. Coagulation process may be modelling through Langmuir and Freundlich adsorption hypothesis, so acceptable r2 coefficients are obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Infrared coagulation: a new treatment for hemorrhoids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leicester, R.J.; Nicholls, R.J.; Mann, C.V.

    Many methods, which have effectively reduced the number of patients requiring hospital admission, have been described for the outpatient treatment of hemorrhoids. However, complications have been reported, and the methods are often associated with unpleasant side effects. In 1977 Neiger et al. described a new method that used infrared coagulation, which produced minimal side effects. The authors have conducted a prospective, randomized trial to evaluate infrared coagulation compared with more traditional methods of treatment. The authors' results show that it may be more effective than injection sclerotherapy in treating non-prolapsing hemorrhoids and that it compares favorably with rubber band ligationmore » in most prolapsing hemorrhoids. No complications occurred, and significantly fewer patients experienced pain after infrared coagulation (P . less than 0.001).« less

  18. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua, E-mail: huangjh@sysucc.org.cn

    ObjectiveTo compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model.Materials and Methods30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy,more » deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.ResultsTemperature–time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm{sup 3}) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm{sup 3}, P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.ConclusionsHAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.« less

  19. Coagulation Testing in Acute Ischemic Stroke Patients Taking Non-Vitamin K Antagonist Oral Anticoagulants.

    PubMed

    Purrucker, Jan C; Haas, Kirsten; Rizos, Timolaos; Khan, Shujah; Poli, Sven; Kraft, Peter; Kleinschnitz, Christoph; Dziewas, Rainer; Binder, Andreas; Palm, Frederick; Jander, Sebastian; Soda, Hassan; Heuschmann, Peter U; Veltkamp, Roland

    2017-01-01

    In patients who present with acute ischemic stroke while on treatment with non-vitamin K antagonist oral anticoagulants (NOACs), coagulation testing is necessary to confirm the eligibility for thrombolytic therapy. We evaluated the current use of coagulation testing in routine clinical practice in patients who were on NOAC treatment at the time of acute ischemic stroke. Prospective multicenter observational RASUNOA registry (Registry of Acute Stroke Under New Oral Anticoagulants; February 2012-2015). Results of locally performed nonspecific (international normalized ratio, activated partial thromboplastin time, and thrombin time) and specific (antifactor Xa tests, hemoclot assay) coagulation tests were documented. The implications of test results for thrombolysis decision-making were explored. In the 290 patients enrolled, nonspecific coagulation tests were performed in ≥95% and specific coagulation tests in 26.9% of patients. Normal values of activated partial thromboplastin time and international normalized ratio did not reliably rule out peak drug levels at the time of the diagnostic tests (false-negative rates 11%-44% [95% confidence interval 1%-69%]). Twelve percent of patients apparently failed to take the prescribed NOAC prior to the acute event. Only 5.7% (9/159) of patients in the 4.5-hour time window received thrombolysis, and NOAC treatment was documented as main reason for not administering thrombolysis in 52.7% (79/150) of patients. NOAC treatment currently poses a significant barrier to thrombolysis in ischemic stroke. Because nonspecific coagulation test results within normal range have a high false-negative rate for detection of relevant drug concentrations, rapid drug-specific tests for thrombolysis decision-making should be established. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01850797. © 2016 American Heart Association, Inc.

  20. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    PubMed

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  1. Coagulation indices in very preterm infants from cord blood and postnatal samples.

    PubMed

    Neary, E; McCallion, N; Kevane, B; Cotter, M; Egan, K; Regan, I; Kirkham, C; Mooney, C; Coulter-Smith, S; Ní Áinle, F

    2015-11-01

    Very premature infants are at high risk of bleeding complications; however, few data exist on ranges for standard coagulation tests. The primary objective of this study was to measure standard plasma coagulation tests and thrombin generation in very premature infants compared with term infants. The secondary objective was to evaluate whether an association existed between coagulation indices and intraventricular hemorrhage (IVH). Cord and peripheral blood of neonates < 30 weeks gestational age (GA) was drawn at birth, on days 1 and 3 and fortnightly until 30 weeks corrected gestational age. Prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen and coagulation factor levels were measured and tissue factor-stimulated thrombin generation was characterized. Control plasma was obtained from cord blood of term neonates. One hundred and sixteen infants were recruited. Median (range) GA was 27.7 (23.7-29.9) weeks and mean (SD) birth weight was 1020 (255) g. Median (5th-95th percentile) day 1 PT, APTT and fibrinogen were 17.5 (12.7-26.6) s, 78.7 (48.7-134.3) s and 1.4 (0.72-3.8) g L(-1) , respectively. No difference in endogenous thrombin potential between preterm and term plasma was observed, where samples were available. Levels of coagulation factors II, VII, IX and X, protein C, protein S and antithrombin were reduced in preterm compared with term plasma. Day 1 APTT and PT were not associated with IVH. In the largest cross-sectional study to date of very preterm infants, typical ranges for standard coagulation tests were determined. Despite long clotting times, thrombin generation was observed to be similar in very preterm and term infants. © 2015 International Society on Thrombosis and Haemostasis.

  2. Coagulation changes during lower body negative pressure and blood loss in humans.

    PubMed

    van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J

    2015-11-01

    We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, -15, -30, and -45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to -45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (-0.42 ± 0.96 during LBNP vs. -2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL. Copyright © 2015 the American Physiological Society.

  3. Synergistic effect of a factor Xa inhibitor, TAK-442, and antiplatelet agents on whole blood coagulation and arterial thrombosis in rats.

    PubMed

    Konishi, Noriko; Hiroe, Katsuhiko; Kawamura, Masaki

    2010-08-01

    Activated platelets facilitate blood coagulation by providing factor V and a procoagulant surface for prothrombinase. Here, we investigated the potential synergy of a potent factor Xa/prothrombinase inhibitor, TAK-442, plus aspirin or clopidogrel in preventing arterial thrombosis and whole blood coagulation. Thrombus formation was initiated by FeCl(3)-induced rat carotid injury. Bleeding time was evaluated with the rat tail transection model. Whole blood coagulation was assessed by thromboelastographic examination (TEG) for which blood obtained from control, aspirin-, or clopidogrel-treated rats was transferred to a TEG analyzer containing, collagen or adenosine diphosphate (ADP), and TAK-442 or vehicle. TAK-442 (3mg/kg, po), aspirin (100mg/kg, po) or clopidogrel (3mg/kg, po) alone had no significant effect on thrombus formation, whereas the combination of TAK-442 with aspirin and clopidogrel remarkably prolonged the time to thrombus formation without additional significant prolongation of bleeding time. TEG demonstrated that the onset of collagen-induced blood coagulation were slightly longer in aspirin-treated rats than control; however, when the blood from aspirin-treated rats was subsequently treated in vitro with 100 nM TAK-442, the onset of clotting was significantly prolonged. In contrast, only marginal prolongation was observed with TAK-442 treatment of blood from control animals. The onset time of ADP-induced blood coagulation was slightly longer in clopidogrel-treated rats compared with control, and it was further extended by TAK-442 treatment. These results demonstrate that blood coagulation can be markedly delayed by the addition of TAK-442 to antiplatelets treatment which could contribute to synergistic antithrombotic efficacy in these settings. (c) 2010 Elsevier Ltd. All rights reserved.

  4. Upregulation of the coagulation factor VII gene during glucose deprivation is mediated by activating transcription factor 4.

    PubMed

    Cronin, Katherine R; Mangan, Thomas P; Carew, Josephine A

    2012-01-01

    Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/- SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/-15% to 188+/-27% and 100+/-8.8% to 176.3+/-17.3% respectively, p<0.001) at 24 hr of treatment. The integrated stress response was induced, as indicated by upregulation of transcription factor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress.

  5. Honey Bee Venom (Apis mellifera) Contains Anticoagulation Factors and Increases the Blood-clotting Time.

    PubMed

    Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi

    2015-12-01

    Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro.

  6. [The blood coagulation system and microcirculatory disorders in ixodid tick-borne borreliosis caused by Borrelia miyamotoi].

    PubMed

    Platonov, A E; Sarksyan, D S; Karan, L S; Shipulin, G A; Gordygina, E V; Malinin, O V; Maleev, V V

    2015-01-01

    To study blood coagulation and microcirculatory disorders as a possible cause of transient dysfunctions of organs (the kidney, liver, heart, lung, etc.) in patients with ixodid tick-borne borreliosis caused by Borrelia miyamotoi (Bmt). SUBJECTS AND METHODS; Twenty-four patients with Lyme disease (LD) and 28 Bmt patients treated at Izhevsk City Hospital (Udmurtia) were examined in the study. Platelet counts and the presence of D-dimers were determined; activated partial thromboplastin time, prothrombin time, thrombin time, fibrinogen and antithrombin III levels, and Factor XIIa-dependent fibrin clot lysis time were measured. Slit lamp microscopy of the conjunctiva was. also carried out. Results. Platelet counts'were less than 150,000 per pL of blood in 43% of the Bmt patients. All the Bmt patients had at least one abnormal coagulation parameter of the eight ones that were tested; 64% of them had marked coagulation disorders with three or more abnormal laboratory findings. In contrast, all the eight parameters were normal in 71% of the LD patients. The other seven LD patients had only one or two abnormal coagulation parameters (p < 0.001 in comparison with Bmt patients). Microscopic examination of eye capillary blood flow revealed pathological findings that included aggregates of erythrocytes and obstructed and/or sinuous capillaries in 22 (79%) of the Bmt patients, but none of the LD patients. A total of 14 Bmt patients had both coagulation and microcirculatory abnormalities. Eleven of them also had transient signs of organ dysfunction. As far as Borrelia secrete no known toxins, we hypothesized that uncovered disorders of blood coagulation and microcirculation in Bmt patients may contribute to organ dysfunction.

  7. Minimizing residual aluminum concentration in treated water by tailoring properties of polyaluminum coagulants.

    PubMed

    Kimura, Masaoki; Matsui, Yoshihiko; Kondo, Kenta; Ishikawa, Tairyo B; Matsushita, Taku; Shirasaki, Nobutaka

    2013-04-15

    Aluminum coagulants are widely used in water treatment plants to remove turbidity and dissolved substances. However, because high aluminum concentrations in treated water are associated with increased turbidity and because aluminum exerts undeniable human health effects, its concentration should be controlled in water treatment plants, especially in plants that use aluminum coagulants. In this study, the effect of polyaluminum chloride (PACl) coagulant characteristics on dissolved residual aluminum concentrations after coagulation and filtration was investigated. The dissolved residual aluminum concentrations at a given coagulation pH differed among the PACls tested. Very-high-basicity PACl yielded low dissolved residual aluminum concentrations and higher natural organic matter (NOM) removal. The low residual aluminum concentrations were related to the low content of monomeric aluminum (Ala) in the PACl. Polymeric (Alb)/colloidal (Alc) ratio in PACl did not greatly influence residual aluminum concentration. The presence of sulfate in PACl contributed to lower residual aluminum concentration only when coagulation was performed at around pH 6.5 or lower. At a wide pH range (6.5-8.5), residual aluminum concentrations <0.02 mg/L were attained by tailoring PACl properties (Ala percentage ≤0.5%, basicity ≥85%). The dissolved residual aluminum concentrations did not increase with increasing the dosage of high-basicity PACl, but did increase with increasing the dosage of normal-basicity PACl. We inferred that increasing the basicity of PACl afforded lower dissolved residual aluminum concentrations partly because the high-basicity PACls could have a small percentage of Ala, which tends to form soluble aluminum-NOM complexes with molecular weights of 100 kDa-0.45 μm. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Improvement of coagulation laboratory practice in Thailand: the first-year experience of the national external quality assessment scheme for blood coagulation.

    PubMed

    Tientadakul, Panutsaya; Opartkiattikul, Nisarat; Wongtiraporn, Wanida

    2009-01-01

    In Thailand until 2005 there had been no external quality assessment scheme at the national level for blood coagulation tests. Only a few laboratories had an external quality assessment for these tests. In the year 2005, the Thailand National External Quality Assessment Scheme for Blood Coagulation was founded. To describe the establishment of the Thailand National External Quality Assessment Scheme for Blood Coagulation (including problems encountered and solutions), its progression and expansion, and the improvement of coagulation laboratory practice in Thailand during 2 trial surveys and 4 formal surveys conducted in the first 1 1/2 years. Between 2005 and 2006, the external quality assessment samples for prothrombin time/international normalized ratio and activated partial thromboplastin time were distributed to the participants as well as the instructions and suggestions for the improvement of laboratory practice. From the data collected, the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time was calculated for each survey. The number of participants increased during the first 1 1/2 years that the surveys were conducted, from 109 to 127. Survey data demonstrate an improvement in response rate and an increase in the number of laboratories that determine their own reference ranges and repeat this for every change of reagent lot, using the appropriate anticoagulant. The increased precision of tests is indicated by the decrease of the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time. Examples of individual laboratory improvement through feedback are also described. The improvement of coagulation laboratory practice both through the instructions provided and liaison with participants was observed during the course of this scheme.

  9. Histology assessment of bipolar coagulation and argon plasma coagulation on digestive tract

    PubMed Central

    Garrido, Teresa; Baba, Elisa R; Wodak, Stephanie; Sakai, Paulo; Cecconello, Ivan; Maluf-Filho, Fauze

    2014-01-01

    AIM: To analyze the effect of bipolar electrocoagulation and argon plasma coagulation on fresh specimens of gastrointestinal tract. METHODS: An experimental evaluation was performed at Hospital das Clinicas of the University of São Paulo, on 31 fresh surgical specimens using argon plasma coagulation and bipolar electrocoagulation at different time intervals. The depth of tissue damage was histopathologically analyzed by single senior pathologist unaware of the coagulation method and power setting applied. To analyze the results, the mucosa was divided in superficial mucosa (epithelial layer of the esophagus and superficial portion of the glandular layer of the stomach and colon) intermediate mucosa (until the lamina propria of the esophagus and until the bottom of the glandular layer of the stomach and colon) and muscularis mucosa. Necrosis involvement of the layers was compared in several combinations of power and time interval. RESULTS: Involvement of the intermediate mucosa of the stomach and of the muscularis mucosa of the three organs was more frequent when higher amounts of energy were used with argon plasma. In the esophagus and in the colon, injury of the intermediate mucosa was frequent, even when small amounts of energy were used. The use of bipolar electrocoagulation resulted in more frequent involvement of the intermediate mucosa and of the muscularis mucosa of the esophagus and of the colon when higher amounts of energy were used. In the stomach, these involvements were rare. The risk of injury of the muscularis propria was significant only in the colon when argon plasma coagulation was employed. CONCLUSION: Tissue damage after argon plasma coagulation is deeper than bipolar electrocoagulation. Both of them depend on the amount of energy used. PMID:25031789

  10. Honey Bee Venom (Apis mellifera) Contains Anticoagulation Factors and Increases the Blood-clotting Time

    PubMed Central

    Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi

    2015-01-01

    Objectives: Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Methods: Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Results: Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. Conclusion: BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro. PMID:26998384

  11. Upregulation of the Coagulation Factor VII Gene during Glucose Deprivation Is Mediated by Activating Transcription Factor 4

    PubMed Central

    Cronin, Katherine R.; Mangan, Thomas P.; Carew, Josephine A.

    2012-01-01

    Background Constitutive production of blood coagulation proteins by hepatocytes is necessary for hemostasis. Stressful conditions trigger adaptive cellular responses and delay processing of most proteins, potentially affecting plasma levels of proteins secreted exclusively by hepatocytes. We examined the effect of glucose deprivation on expression of coagulation proteins by the human hepatoma cell line, HepG2. Methodology/Principal Findings Expression of coagulation factor VII, which is required for initiation of blood coagulation, was elevated by glucose deprivation, while expression of other coagulation proteins decreased. Realtime PCR and ELISA demonstrated that the relative percentage expression +/− SD of steady-state F7 mRNA and secreted factor VII antigen were significantly increased (from 100+/−15% to 188+/−27% and 100+/−8.8% to 176.3+/−17.3% respectively, p<0.001) at 24 hr of treatment. The integrated stress response was induced, as indicated by upregulation of transcription factor ATF4 and of additional stress-responsive genes. Small interfering RNAs directed against ATF4 potently reduced basal F7 expression, and prevented F7 upregulation by glucose deprivation. The response of the endogenous F7 gene was replicated in reporter gene assays, which further indicated that ATF4 effects were mediated via interaction with an amino acid response element in the F7 promoter. Conclusions/Significance Our data indicated that glucose deprivation enhanced F7 expression in a mechanism reliant on prior ATF4 upregulation primarily due to increased transcription from the ATF4 gene. Of five coagulation protein genes examined, only F7 was upregulated, suggesting that its functions may be important in a systemic response to glucose deprivation stress. PMID:22848420

  12. [Investigation on the impact of hot temperature methods of the tissue dissection and coagulation on parenchymatous organs in experiment].

    PubMed

    Sukhin, I A; Khudets'kyĭ, I Iu; Kachan, S H; Bilylovets', O M

    2013-01-01

    There are adduced the results of experimental operations on mongrel rabbits with dissection and coagulation of the liver and the spleen, using highly temperature coagulation apparatuses of various kinds. There was established, that while application of various highly temperature technologies a typical process occurs, consisting of the heat spreading inside the organ. The temperature raising grade depends on the method and duration of the impact.

  13. Plasmodium falciparum cerebral malaria complicated by disseminated intravascular coagulation and symmetrical peripheral gangrene: case report and review.

    PubMed

    Liechti, M E; Zumsteg, V; Hatz, C F R; Herren, T

    2003-09-01

    The case of a 56-year-old female tourist who survived cerebral Plasmodium falciparum malaria with disseminated intravascular coagulation and symmetrical peripheral gangrene, ultimately requiring amputation of her left-sided fingertips and toes, is reported. While symmetrical peripheral gangrene has been described rarely in Asian, African, and American patients with Plasmodium falciparum malaria and disseminated intravascular coagulation, no such case has been reported in travelers returning from endemic areas.

  14. Multiple response optimization of the coagulation process for upgrading the quality of effluent from municipal wastewater treatment plant

    NASA Astrophysics Data System (ADS)

    Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J.; Sheng, Guo-Ping

    2016-05-01

    To meet the high quality standard of receiving water, the coagulation process using polyferric chloride (PFC) was used to further improve the water quality of effluent from wastewater treatment plants. Uniform design (UD) coupled with response surface methodology (RSM) was adopted to assess the effects of the main influence factors: coagulant dosage, pH and basicity, on the removal of total organic carbon (TOC), NH4+-N and PO43--P. A desirability function approach was used to effectively optimize the coagulation process for the comprehensive removal of TOC, NH4+-N and PO43--P to upgrade the effluent quality in practical application. The optimized operating conditions were: dosage 28 mg/L, pH 8.5 and basicity 0.001. The corresponding removal efficiencies for TOC, NH4+-N and PO43--P were 77.2%, 94.6% and 20.8%, respectively. More importantly, the effluent quality could upgrade to surface water Class V of China through coagulation under optimal region. In addition, grey relational analysis (GRA) prioritized these three factors as: pH > basicity > dosage (for TOC), basicity > dosage > pH (for NH4+-N), pH > dosage > basicity (for PO43--P), which would help identify the most important factor to control the treatment efficiency of various effluent quality indexes by PFC coagulation.

  15. Coagulation factor Xa drives tumor cells into apoptosis through BH3-only protein Bim up-regulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borensztajn, Keren S.; Bijlsma, Maarten F.; Groot, Angelique P.

    2007-07-15

    Coagulation Factor (F)Xa is a serine protease that plays a crucial role during blood coagulation by converting prothrombin into active thrombin. Recently, however, it emerged that besides this role in coagulation, FXa induces intracellular signaling leading to different cellular effects. Here, we show that coagulation factor (F)Xa drives tumor cells of epithelial origin, but not endothelial cells or monocytes, into apoptosis, whereas it even enhances fibroblast survival. FXa signals through the protease activated receptor (PAR)-1 to activate extracellular-signal regulated kinase (ERK) 1/2 and p38. This activation is associated with phosphorylation of the transcription factor CREB, and in tumor cells withmore » up-regulation of the BH3-only pro-apoptotic protein Bim, leading to caspase-3 cleavage, the main hallmark of apoptosis. Transfection of tumor cells with dominant negative forms of CREB or siRNA for either PAR-1, Bim, ERK1 and/or p38 inhibited the pro-apoptotic effect of FXa. In fibroblasts, FXa-induced PAR-1 activation leads to down-regulation of Bim and pre-treatment with PAR-1 or Bim siRNA abolishes proliferation. We thus provide evidence that beyond its role in blood coagulation, FXa plays a key role in cellular processes in which Bim is the central player in determining cell survival.« less

  16. Coagulation-flocculation mechanisms in wastewater treatment plants through zeta potential measurements.

    PubMed

    López-Maldonado, E A; Oropeza-Guzman, M T; Jurado-Baizaval, J L; Ochoa-Terán, A

    2014-08-30

    Based on the polyelectrolyte-contaminant physical and chemical interactions at the molecular level, this article analyzed and discussed the coagulation-flocculation and chemical precipitation processes in order to improve their efficiency. Bench experiments indicate that water pH, polyelectrolyte (PE) dosing strategy and cationic polyelectrolyte addition are key parameters for the stability of metal-PE complexes. The coagulation-flocculation mechanism is proposed based on zeta potential (ζ) measurement as the criteria to define the electrostatic interaction between pollutants and coagulant-flocculant agents. Polyelectrolyte and wastewater dispersions are exposed to an electrophoretic effect to determine ζ. Finally, zeta potential values are compared at pH 9, suggesting the optimum coagulant dose at 162mg/L polydadmac and 67mg/L of flocculant, since a complete removal of TSS and turbidity is achieved. Based on the concentration of heavy metals (0.931mg/L Sn, 0.7mg/L Fe and 0.63mg/L Pb), treated water met the Mexican maximum permissible limits. In addition, the treated water has 45mg O2/L chemical oxygen demand (COD) and 45mg C/L total organic carbon (TOC). The coagulation-flocculation mechanism is proposed taking into account both: zeta potential (ζ)-pH measurement and chemical affinity, as the criteria to define the electrostatic and chemical interaction between pollutants and polyelectrolytes. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Development and Implementation of a Coagulation Factor Testing Method Utilizing Autoverification in a High-volume Clinical Reference Laboratory Environment

    PubMed Central

    Riley, Paul W.; Gallea, Benoit; Valcour, Andre

    2017-01-01

    Background: Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. Methods: The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Results: Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. Conclusions: To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process. PMID:28706751

  18. Development and Implementation of a Coagulation Factor Testing Method Utilizing Autoverification in a High-volume Clinical Reference Laboratory Environment.

    PubMed

    Riley, Paul W; Gallea, Benoit; Valcour, Andre

    2017-01-01

    Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process.

  19. Confinement Regulates Complex Biochemical Networks: Initiation of Blood Clotting by “Diffusion Acting”

    PubMed Central

    Shen, Feng; Pompano, Rebecca R.; Kastrup, Christian J.; Ismagilov, Rustem F.

    2009-01-01

    Abstract This study shows that environmental confinement strongly affects the activation of nonlinear reaction networks, such as blood coagulation (clotting), by small quantities of activators. Blood coagulation is sensitive to the local concentration of soluble activators, initiating only when the activators surpass a threshold concentration, and therefore is regulated by mass transport phenomena such as flow and diffusion. Here, diffusion was limited by decreasing the size of microfluidic chambers, and it was found that microparticles carrying either the classical stimulus, tissue factor, or a bacterial stimulus, Bacillus cereus, initiated coagulation of human platelet-poor plasma only when confined. A simple analytical argument and numerical model were used to describe the mechanism for this phenomenon: confinement causes diffusible activators to accumulate locally and surpass the threshold concentration. To interpret the results, a dimensionless confinement number, Cn, was used to describe whether a stimulus was confined, and a Damköhler number, Da2, was used to describe whether a subthreshold stimulus could initiate coagulation. In the context of initiation of coagulation by bacteria, this mechanism can be thought of as “diffusion acting”, which is distinct from “diffusion sensing”. The ability of confinement and diffusion acting to change the outcome of coagulation suggests that confinement should also regulate other biological “on” and “off” processes that are controlled by thresholds. PMID:19843446

  20. Enzymatically oxidized phospholipids restore thrombin generation in coagulation factor deficiencies.

    PubMed

    Slatter, David A; Percy, Charles L; Allen-Redpath, Keith; Gajsiewicz, Joshua M; Brooks, Nick J; Clayton, Aled; Tyrrell, Victoria J; Rosas, Marcela; Lauder, Sarah N; Watson, Andrew; Dul, Maria; Garcia-Diaz, Yoel; Aldrovandi, Maceler; Heurich, Meike; Hall, Judith; Morrissey, James H; Lacroix-Desmazes, Sebastien; Delignat, Sandrine; Jenkins, P Vincent; Collins, Peter W; O'Donnell, Valerie B

    2018-03-22

    Hemostatic defects are treated using coagulation factors; however, clot formation also requires a procoagulant phospholipid (PL) surface. Here, we show that innate immune cell-derived enzymatically oxidized phospholipids (eoxPL) termed hydroxyeicosatetraenoic acid-phospholipids (HETE-PLs) restore hemostasis in human and murine conditions of pathological bleeding. HETE-PLs abolished blood loss in murine hemophilia A and enhanced coagulation in factor VIII- (FVIII-), FIX-, and FX-deficient human plasma . HETE-PLs were decreased in platelets from patients after cardiopulmonary bypass (CPB). To explore molecular mechanisms, the ability of eoxPL to stimulate individual isolated coagulation factor/cofactor complexes was tested in vitro. Extrinsic tenase (FVIIa/tissue factor [TF]), intrinsic tenase (FVIIIa/FIXa), and prothrombinase (FVa/FXa) all were enhanced by both HETE-PEs and HETE-PCs, suggesting a common mechanism involving the fatty acid moiety. In plasma, 9-, 15-, and 12-HETE-PLs were more effective than 5-, 11-, or 8-HETE-PLs, indicating positional isomer specificity. Coagulation was enhanced at lower lipid/factor ratios, consistent with a more concentrated area for protein binding. Surface plasmon resonance confirmed binding of FII and FX to HETE-PEs. HETE-PEs increased membrane curvature and thickness, but not surface charge or homogeneity, possibly suggesting increased accessibility to cations/factors. In summary, innate immune-derived eoxPL enhance calcium-dependent coagulation factor function, and their potential utility in bleeding disorders is proposed.

  1. Enzymatically oxidized phospholipids restore thrombin generation in coagulation factor deficiencies

    PubMed Central

    Slatter, David A.; Percy, Charles L.; Allen-Redpath, Keith; Gajsiewicz, Joshua M.; Brooks, Nick J.; Tyrrell, Victoria J.; Lauder, Sarah N.; Watson, Andrew; Dul, Maria; Garcia-Diaz, Yoel; Aldrovandi, Maceler; Heurich, Meike; Hall, Judith; Lacroix-Desmazes, Sebastien; Delignat, Sandrine; Jenkins, P. Vincent; Collins, Peter W.; O’Donnell, Valerie B.

    2018-01-01

    Hemostatic defects are treated using coagulation factors; however, clot formation also requires a procoagulant phospholipid (PL) surface. Here, we show that innate immune cell–derived enzymatically oxidized phospholipids (eoxPL) termed hydroxyeicosatetraenoic acid–phospholipids (HETE-PLs) restore hemostasis in human and murine conditions of pathological bleeding. HETE-PLs abolished blood loss in murine hemophilia A and enhanced coagulation in factor VIII- (FVIII-), FIX-, and FX-deficient human plasma . HETE-PLs were decreased in platelets from patients after cardiopulmonary bypass (CPB). To explore molecular mechanisms, the ability of eoxPL to stimulate individual isolated coagulation factor/cofactor complexes was tested in vitro. Extrinsic tenase (FVIIa/tissue factor [TF]), intrinsic tenase (FVIIIa/FIXa), and prothrombinase (FVa/FXa) all were enhanced by both HETE-PEs and HETE-PCs, suggesting a common mechanism involving the fatty acid moiety. In plasma, 9-, 15-, and 12-HETE-PLs were more effective than 5-, 11-, or 8-HETE-PLs, indicating positional isomer specificity. Coagulation was enhanced at lower lipid/factor ratios, consistent with a more concentrated area for protein binding. Surface plasmon resonance confirmed binding of FII and FX to HETE-PEs. HETE-PEs increased membrane curvature and thickness, but not surface charge or homogeneity, possibly suggesting increased accessibility to cations/factors. In summary, innate immune-derived eoxPL enhance calcium-dependent coagulation factor function, and their potential utility in bleeding disorders is proposed. PMID:29563336

  2. Assessing the application and downstream effects of pulsed mode ultrasound as a pre-treatment for alum coagulation.

    PubMed

    Al-Juboori, Raed A; Aravinthan, Vasantha; Yusaf, Talal; Bowtell, Leslie

    2016-07-01

    The application of pulsed mode ultrasound (PMU) as a pre-treatment for alum coagulation was investigated at various alum dosages and pH levels. The effects of the treatments on turbidity and dissolved organic carbon (DOC) removal and residual Al were evaluated. Response surface methodology (RSM) was utilized to optimize the operating conditions of the applied treatments. The results showed that PMU pre-treatment increased turbidity and DOC removal percentages from maximum of 96.6% and 43% to 98.8% and 52%, respectively. It also helped decrease the minimum residual Al from 0.100 to 0.094 ppm. The multiple response optimization was carried out using the desirability function. A desirability value of >0.97 estimated respective turbidity removal, DOC removal and Al residual of 89.24%, 45.66% and ∼ 0.1 ppm for coagulation (control) and 90.61%, >55% and ∼ 0 for coagulation preceded by PMU. These figures were validated via confirmatory experiments. PMU pre-treatment increased total coliform removal from 80% to >98% and decreased trihalomethane formation potential (THMFP) from 250 to 200 ppb CH3Cl. Additionally, PMU application prior to coagulation improved the settleability of sludge due to the degassing effects. The results of this study confirms that PMU pre-treatment can significantly improve coagulation performance. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Improving primary treatment of urban wastewater with lime-induced coagulation.

    PubMed

    Marani, Dario; Ramadori, Roberto; Braguglia, Camilla Maria

    2004-01-01

    The enhancement of primary treatment efficiency through the coagulation process may yield several advantages, including lower aeration energy in the subsequent biological unit and higher recovery of biogas from sludge digestion. In this work sewage coagulation with lime was studied at pilot plant level, using degritted sewage from the city of Rome. The work aimed at optimising the operating conditions (coagulant dosage or treatment pH, and mixing conditions in the coagulation and flocculation tanks), in order to maximise the efficiency of suspended Chemical Oxygen Demand (COD) removal and to minimise sludge production. Lime dosage optimisation resulted in an optimal treatment pH of 9. Lime addition up to pH 9 may increase COD removal rate in the primary treatment from typical 30-35% of plain sedimentation up to 55-70%. Within the velocity gradients experimented in this work (314-795 s(-1) for the coagulation tank and 13-46 s(-1) for the flocculation tank), mixing conditions did not significantly affect the lime-enhanced process, which seems to be controlled by slow lime dissolution. Sludge produced in the lime-enhanced process settled and compacted easily, inducing an average 36% decrease in sludge volume with respect to plain settling. However excess sludge was produced, which was not accounted for by the amount of suspended solids removed. This is probably due to incomplete dissolution of lime, which may be partially incorporated in the sludge.

  4. Investigating the effect of hardness cations on coagulation: The aspect of neutralisation through Al(III)-dissolved organic matter (DOM) binding.

    PubMed

    Zhou, Yuxuan; Yan, Mingquan; Liu, Ruiping; Wang, Dongsheng; Qu, Jiuhui

    2017-05-15

    Hardness cations are ubiquitous and abundant in source water, while the effect of hardness on the performance of coagulation for dissolved organic matter (DOM) removal in water treatment remains unclear due to the limitation of methods that can characterise the subtle interactions between DOM, coagulant and hardness cations. This work quantified the competition between coagulant Al 3+ and hardness cations to bind onto DOM using absorbance spectroscopy acquired at different Al 3+ concentrations in the absence and presence of Ca 2+ or Mg 2+ . The results indicate that, in the presence of either Mg 2+ or Ca 2+ , an increasing depression of the binding of Al 3+ -DOM could be observed in the differential spectra of DOM with the increasing of Mg 2+ or Ca 2+ at a level of 10, 100 and 1000 μM, with the observation being more significant at higher pH from 6.5 to 8.5. The results of zeta potentials of DOM indicate that the competition of hardness cations results in the negative DOM being less efficiently neutralised by Al 3+ . This study demonstrates that the removal of DOM by coagulation would significantly deteriorate with the presence of hardness cations, which would compete with coagulant Al 3+ to neutralise the unsaturated sites in DOM. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Using quartz sand to enhance the removal efficiency of M. aeruginosa by inorganic coagulant and achieve satisfactory settling efficiency.

    PubMed

    Pei, Haiyan; Jin, Yan; Xu, Hangzhou; Ma, Chunxia; Sun, Jiongming; Li, Hongmin

    2017-10-19

    In this study, low-cost and non-polluting quartz sand was respectively mixed with AlCl 3 , FeCl 3 and PAFC to synergistically remove Microcystis aeruginosa. Results showed that quartz sand could markedly increase the algae removal efficiency and decrease the coagulant doses. The increase of removal efficiency with AlCl 3 and FeCl 3 was only due to the enhancement of floc density by the quartz sand. However, the removal efficiency with PAFC was increased not only by the enhanced floc density, but also by the enlarged floc size. Flocs from 50 mg/L sand addition were larger than that with other sand doses, which was on account of the appropriate enhancement of collision efficiency at this dose. After coagulation, the extracellular organic matter (EOM) and microcystins (MCs) in system with quartz sand was remarkably reduced. That's because quartz sand can enhance the coagulation so as to improve capping the EOM and MCs in flocs during coagulation process. Owing to 200 mg/L quartz sand could damage the cell's membrane during coagulation proces, algal cells in the system lysed two days earlier than with 50 mg/L sand during flocs storage. In addition, cells with PAFC incurred relatively moderate cellular oxidative damage and could remain intact for longer time.

  6. Short communication: Effects of pregnancy on milk yield, composition traits, and coagulation properties of Holstein cows.

    PubMed

    Penasa, M; De Marchi, M; Cassandro, M

    2016-06-01

    The aim of this study was to investigate the effect of pregnancy stage on milk yield, composition traits, and milk coagulation properties in Italian Holstein cattle. The data set included 25,729 records from 3,995 first-parity cows calving between August 2010 and August 2013 in 167 herds. The traits analyzed were milk yield (kg/d), fat (%), protein (%), casein (%), and lactose (%) contents, pH, somatic cell score, rennet coagulation time (min), and curd firmness (mm). To better understand the effect of gestation on the aforementioned traits, each record was assigned to one of the following classes of pregnancy stage: (1) nonpregnant, (2) pregnant from 1 to 120d, (3) pregnant from 121 to 210d, and (4) pregnant from 211 to 310d. Gestation stage significantly influenced all studied traits with the exception of somatic cell score. Milk production decreased and milk quality improved from the fourth month of pregnancy onward. For all traits, nonpregnant cows performed very similarly to cows in the first period of gestation. Rennet coagulation time and curd firmness were influenced by pregnancy stage, especially in the last weeks of gestation when milk had better coagulation characteristics; this information should be accounted for to adjust test-day records in genetic evaluation of milk coagulation properties. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. 21 CFR 864.7750 - Prothrombin time test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the detection of possible clotting factor deficiencies in the extrinsic coagulation pathway, which involves the reaction between coagulation factors III and VII, and to monitor patients receiving coumarin...

  8. Red blood cells aggregability measurement of coagulating blood in extracorporeal circulation system with multiple-frequency electrical impedance spectroscopy.

    PubMed

    Li, Jianping; Sapkota, Achyut; Kikuchi, Daisuke; Sakota, Daisuke; Maruyama, Osamu; Takei, Masahiro

    2018-07-30

    Red blood cells (RBCs) aggregability A G of coagulating blood in extracorporeal circulation system has been investigated under the condition of pulsatile flow. Relaxation frequency f c from the multiple-frequency electrical impedance spectroscopy is utilized to obtain RBCs aggregability A G . Compared with other methods, the proposed multiple-frequency electrical impedance method is much easier to obtain non-invasive measurement with high speed and good penetrability performance in biology tissues. Experimental results show that, RBCs aggregability A G in coagulating blood falls down with the thrombus formation while that in non-coagulation blood almost keeps the same value, which has a great agreement with the activated clotting time (ACT) fibrinogen concertation (F bg ) tests. Modified Hanai formula is proposed to quantitatively analyze the influence of RBCs aggregation on multiple-frequency electrical impedance measurement. The reduction of RBCs aggregability A G is associated with blood coagulation reaction, which indicates the feasibility of the high speed, compact and cheap on-line thrombus measurement biosensors in extracorporeal circulation systems. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Characterization of micro-flocs of NOM coagulated by PACl, alum and polysilicate-iron in terms of molecular weight and floc size.

    PubMed

    Fusheng, Li; Akira, Yuasa; Yuka, Ando

    2008-01-01

    Micro-flocs of NOM coagulated by polyaluminium chloride (PACl), alum and polysilicate-iron (PSI) were characterized by flocs size, HPSEC-based molecular weight and the captured content of coagulants-based aluminium and iron. Changes in floc composition with respect to the mass ratios of captured NOM to Al and Fe were examined. Lowering water pH to optimum levels was found to be capable of removing small NOM constituents that are generally difficult to be precipitated at neutral pH levels. For PACl and PSI, the distribution of micro flocs (0.1-5.0 microm) reached steady stage after rapid mixing for 30 seconds, with NOM being found existent within the non-coagulated fraction (d<0.1 microm) and the coagulated fraction with floc sizes above 5.0 microm (d >5.0 microm). For alum, however, the existence of NOM inside intermediate floc fractions of d = 0.1-1.0 microm, 1.0-3.0microm and 3.0-5.0 microm was confirmed.

  10. Treatment of melanoidin wastewater by anaerobic digestion and coagulation.

    PubMed

    Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe

    2015-01-01

    Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.

  11. Composite wastewater treatment by aerated electrocoagulation and modified peroxi-coagulation processes.

    PubMed

    Kumar, Abhijeet; Nidheesh, P V; Suresh Kumar, M

    2018-08-01

    Treatment of composite wastewater generating from the industrial estates is a great challenge. The present study examines the applicability of aerated electrocoagulation and modified peroxi-coagulation processes for removing color and COD from composite wastewater. Iron plates were used as anodes and cathodes in both electrochemical processes and experiments were carried out in a working volume of 2 L. Aeration enhanced the efficiency of electrocoagulation process significantly. More than 50% of COD and 60% of color were removed after 1 h of electrocoagulation process operated at pH 3 and applied voltage of 1 V. Efficiency of the modified peroxi-coagulation process was significantly higher than that of aerated electrocoagulation. COD and color removal efficiencies of the modified peroxi-coagulation process were found as 77.7% and 97%, respectively after 1 h of electrolysis operated at 1 V, solution pH 3 and 50 mM hydrogen peroxide addition. This improved efficiency of modified peroxi-coagulation compared to aerated electrocoagulation is mainly due to the attack of in-situ generated hydroxyl radicals. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    PubMed Central

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-01-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen. PMID:27090437

  13. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-04-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen.

  14. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler.

    PubMed

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E; Boudoux, Caroline

    2015-04-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett's esophagus.

  15. Valorization of Waste Obtained from Oil Extraction in Moringa Oleifera Seeds: Coagulation of Reactive Dyes in Textile Effluents.

    PubMed

    Vilaseca, Mercè; López-Grimau, Víctor; Gutiérrez-Bouzán, Carmen

    2014-09-12

    Moringa oleifera seeds contain about 40% of highly valued oil due to its wide range of applications, from nutritional issues to cosmetics or biodiesel production. The extraction of Moringa oil generates a waste (65%-75% of seeds weight) which contains a water soluble protein able to be used either in drinking water clarification or wastewater treatment. In this paper, the waste of Moringa oleifera extraction was used as coagulant to remove five reactive dyes from synthetic textile effluents. This waste constitutes a natural coagulant which was demonstrated to be effective for the treatment of industrial reactive dyestuff effluents, characterized by alkaline pH, high NaCl content and hydrolyzed dyes. The coagulation yield increased at high NaCl concentration, whereas the pH did not show any significant effect on dye removal. Moringa oleifera showed better results for dye removal than the conventional treatment of coagulation-flocculation with FeCl₃ and polyelectrolyte. Treated water can be reused in new dyeing processes of cotton fabrics with high quality results.

  16. [Effect of UV Light Radiation on the Coagulation of Chlorella and Its Mechanism].

    PubMed

    Wang, Wen-dong; Zhang, Ke; Xu, Hong-bin; Liu, Guo-qi

    2016-01-15

    Considering algae were difficult to be effectively removed in conventional water treatment process, UV radiation was used to enhance the coagulation of algae in this study. The results showed that with the increase of radiation time, the removal rates of both algae and turbidity experienced a decrease after an increase, and reached their maximum values at 50 min. When the dosage of PAC was 5 mg x L(-1), the removal rates of algae and turbidity of the radiated sample were 20.1% and 18% higher than the blank sample, respectively. When pH ranged from 6 to 9, the coagulation efficiency varied little. At pH 8 and with a radiation time of 50 min, the removal rates of algae and turbidity reached 93.5% and 90.6%, respectively. Meanwhile, the Zeta potential reached the maximum, and the algae generated extracellular organic matter, which favored the subsequent coagulation. After radiated for 60 min, the algal cells was destroyed, leading to a release of intracellular organic matter into the solution. Accordingly, the Zeta potential decreased, which had a negative effect on the subsequent coagulation process.

  17. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler

    PubMed Central

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline

    2015-01-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett’s esophagus. PMID:25909013

  18. Differential roles of tissue factor and phosphatidylserine in activation of coagulation.

    PubMed

    Spronk, Henri M H; ten Cate, Hugo; van der Meijden, Paola E J

    2014-05-01

    It has been suggested that the main physiological trigger of coagulation, tissue factor, possesses limited procoagulant activity and occurs in an inactive or so-called encrypted state. For the conversion of encrypted into decrypted tissue factor with sufficient procoagulant activity, four distinct models have been proposed: 1; dimer formation, 2; lipid rafts, 3; disulfide bonds, and 4; phosphatidylserine exposure. Pro and cons can be given for each of these mechanisms of tissue factor encryption/decryption, however, it seems most likely that two or more mechanisms act together in activating the procoagulant activity. The exposure of phosphatidylserine in the outer layer of cell membranes supports coagulation through enhanced formation of the tenase (factors IXa, VIIIa and X) and prothrombinase (factors Xa, Va and prothrombin) complexes. The proposed role for phosphatidylserine in decryption of tissue factor could contribute to the correct orientation of the tissue factor - factor VII complex. Overall, the contribution of both tissue factor and phosphatidylserine to coagulation seems distinct with tissue factor being the physiological activator and phosphatidylserine the driving force of propagation of coagulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. [Pilot study on pentavalent arsenic removal by coagulation and the strengthening effect of flocs recycling].

    PubMed

    Yao, Juan-Juan; Gao, Nai-Yun; Xia, Sheng-Ji; Chen, Bei-Bei

    2009-06-15

    The pilot and bench scale studies on pentavalent arsenic removal by coagulation and the strengthening effect of flocs recycling were performed. The results show that above 95% As (V) in the raw water exists in the form of dissolved As (V). Furthermore, the removal efficiencies of dissolved arsenic and total arsenic by mixing, first flocculation, second flocculation, sedimentation, filtration units were 87.92%, 6.18%, 2.38%, 1.55%, 1.23% and 1.10%, 1.83%, 2.20%, 86.42%, 7.38% respectively. Therefore, conversion rate of dissolved As(V) into particulate As(V) and the settlement performance of flocs were strongly dependent on the coagulation effect, which determined the As(V) removal efficiency in the whole system. Flocs have a strong adsorption capacity for As(V) and the adsorption obeys a second order reaction kinetics and well fits the modified Freundlich model. Flocs recycling can obviously promoted the As(V) removal by enhanced coagulation and reduce the dosage of coagulant with recycling point set at rapid mixed site and recycling ratio at 50%.

  20. Removal of boron (B) from waste liquors.

    PubMed

    Jiang, J Q; Xu, Y; Simon, J; Quill, K; Shettle, K

    2006-01-01

    This paper explores the use of electrocoagulation to remove boron from waste effluent in comparison with alum coagulation. In treating model test wastes, greater boron removals were achieved with electrocoagulation at low doses than conventional alum coagulation when reaction was undertaken for the same conditions (pH 8.5, and initial boron concentration was 500 mg/L). Al electrocoagulation can achieve good boron removal performance (68.3%) at a dose of 2.1 (as molar ratio of Al:B, and for current density of 62.1 A/m2), while alum coagulation can only achieve the maximum boron removal of 56% at a dose of 2.4. Also, Al electrocoagulation can remove 15-20% more boron than alum coagulation for the same dose compared in the treatment of both model test wastes and industry effluent. The estimation of running costs shows that to achieve 75% boron removal from industry waste effluent, i.e. removing 150 g of boron from 1 m3 of effluent, electrocoagulation was 6.2 times cheaper than alum coagulation. The economic advantage of electrocoagulation in the treatment of boron-containing waste effluent is thus significant.

  1. Coagulation-Fenton coupled treatment for ecotoxicity reduction in highly polluted industrial wastewater.

    PubMed

    Perdigón-Melón, J A; Carbajo, J B; Petre, A L; Rosal, R; García-Calvo, E

    2010-09-15

    A coupled coagulation-Fenton process was applied for the treatment of cosmetic industry effluents. In a first step, FeSO(4) was used as coagulant and the non-precipitated Fe(2+) remaining in dissolution was used as catalyst in the further Fenton process. In the coagulation process a huge decrease in total organic carbon (TOC) was achieved, but the high concentration of phenol derivatives was not diminished. The decrease in TOC in the coagulation step significantly reduces the amount of H(2)O(2) required in the Fenton process for phenol depletion. The coupled process, using a H(2)O(2) dose of only 2 g l(-1), reduced TOC and total phenol to values lower than 40 and 0.10 mg l(-1), respectively. The short reaction period (less than 15 min) in TOC and phenol degradation bodes well for improving treatment in a continuous regime. The combination of both processes significantly reduced the ecotoxicity of raw effluent and markedly increased its biodegradability, thus allowing easier treatment by the conventional biological units in conventional sewage treatment plants (STPs). Copyright 2010 Elsevier B.V. All rights reserved.

  2. Valorization of Waste Obtained from Oil Extraction in Moringa Oleifera Seeds: Coagulation of Reactive Dyes in Textile Effluents

    PubMed Central

    Vilaseca, Mercè; López-Grimau, Víctor; Gutiérrez-Bouzán, Carmen

    2014-01-01

    Moringa oleifera seeds contain about 40% of highly valued oil due to its wide range of applications, from nutritional issues to cosmetics or biodiesel production. The extraction of Moringa oil generates a waste (65%–75% of seeds weight) which contains a water soluble protein able to be used either in drinking water clarification or wastewater treatment. In this paper, the waste of Moringa oleifera extraction was used as coagulant to remove five reactive dyes from synthetic textile effluents. This waste constitutes a natural coagulant which was demonstrated to be effective for the treatment of industrial reactive dyestuff effluents, characterized by alkaline pH, high NaCl content and hydrolyzed dyes. The coagulation yield increased at high NaCl concentration, whereas the pH did not show any significant effect on dye removal. Moringa oleifera showed better results for dye removal than the conventional treatment of coagulation-flocculation with FeCl3 and polyelectrolyte. Treated water can be reused in new dyeing processes of cotton fabrics with high quality results. PMID:28788199

  3. A scaling theory for number-flux distributions generated during steady-state coagulation and settling and application to particles in Lake Zurich, Switzerland.

    PubMed

    Boehm, Alexandria B

    2002-10-15

    In this study, we extend the established scaling theory for cluster size distributions generated during unsteady coagulation to number-flux distributions that arise during steady-state coagulation and settling in an unmixed water mass. The scaling theory predicts self-similar number-flux distributions and power-law decay of total number flux with depth. The shape of the number-flux distributions and the power-law exponent describing the decay of the total number flux are shown to depend on the homogeneity and small i/j limit of the coagulation kernel and the exponent kappa, which describes the variation in settling velocity with cluster volume. Particle field measurements from Lake Zurich, collected by U. Weilenmann and co-workers (Limnol. Oceanogr.34, 1 (1989)), are used to illustrate how the scaling predictions can be applied to a natural system. This effort indicates that within the mid-depth region of Lake Zurich, clusters of the same size preferentially interact and large clusters react with one another more quickly than small ones, indicative of clusters coagulating in a reaction-limited regime.

  4. Optimization of coagulation-flocculation treatment on paper-recycling wastewater: Application of response surface methodology.

    PubMed

    Birjandi, Noushin; Younesi, Habibollah; Bahramifar, Nader; Ghafari, Shahin; Zinatizadeh, Ali Akbar; Sethupathi, Sumathi

    2013-01-01

    The application of coagulation-flocculation (CF) process for treating the paper-recycling wastewater in jar-test experiment was employed. The purpose of the study was aimed to examine the efficiency of alum and poly aluminum chloride (PACl) in combination with a cationic polyacrylamide (C-PAM) in removal of chemical oxygen demand (COD) and turbidity from paper-recycling wastewater. Optimization of CF process were performed by varying independent parameters (coagulants dosage, flocculants dosage, initial COD and pH) using a central composite design (CCD) under response surface methodology (RSM). Maximum set required 4.5 as pH, 40 mg/L coagulants dosage and 4.5 mg/L flocculants dosage at which gave 92% reduction of turbidity, 97% of COD removal and SVI 80 mL/g. The best coagulant and flocculants were alum and chemfloc 3876 at dose of 41 and 7.52 mg/L, respectively, correspondingly at pH of 6.85. These conditions gave 91.30% COD and 95.82% turbidity removals and 12 mL/g SVI.

  5. Comparison between coagulation-flocculation and ozone-flotation for Scenedesmus microalgal biomolecule recovery and nutrient removal from wastewater in a high-rate algal pond.

    PubMed

    Oliveira, Gislayne Alves; Carissimi, Elvis; Monje-Ramírez, Ignacio; Velasquez-Orta, Sharon B; Rodrigues, Rafael Teixeira; Ledesma, María Teresa Orta

    2018-07-01

    The removal of nutrients by Scenedesmus sp. in a high-rate algal pond, and subsequent algal separation by coagulation-flocculation or flotation with ozone to recover biomolecules, were evaluated. Cultivation of Scenedesmus sp. in wastewater resulted in complete NH 3 -H removal, plus 93% total nitrogen and 61% orthophosphate removals. Ozone-flotation obtained better water quality results than coagulation-flocculation for most parameters (NH 3 -N, NTK, nitrate and nitrite) except orthophosphate. Ozone-flotation, also produced the highest recovery of lipids, carbohydrates and proteins which were 0.32 ± 0.03, 0.33 ± 0.025 and 0.58 ± 0.014 mg/mg of biomass, respectively. In contrast, there was a low lipid extraction of 0.21 mg of lipids/mg of biomass and 0.12-0.23 mg of protein/mg of biomass in the coagulation-flocculation process. In terms of biomolecule recovery and water quality, ozone showed better results than coagulation-flocculation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Removal of disinfection by-product precursors by coagulation and an innovative suspended ion exchange process.

    PubMed

    Metcalfe, David; Rockey, Chris; Jefferson, Bruce; Judd, Simon; Jarvis, Peter

    2015-12-15

    This investigation aimed to compare the disinfection by-product formation potentials (DBPFPs) of three UK surface waters (1 upland reservoir and 2 lowland rivers) with differing characteristics treated by (a) a full scale conventional process and (b) pilot scale processes using a novel suspended ion exchange (SIX) process and inline coagulation (ILCA) followed by ceramic membrane filtration (CMF). Liquid chromatography-organic carbon detection analysis highlighted clear differences between the organic fractions removed by coagulation and suspended ion exchange. Pretreatments which combined SIX and coagulation resulted in significant reductions in dissolved organic carbon (DOC), UV absorbance (UVA), trihalomethane and haloacetic acid formation potential (THMFP, HAAFP), in comparison with the SIX or coagulation process alone. Further experiments showed that in addition to greater overall DOC removal, the processes also reduced the concentration of brominated DBPs and selectively removed organic compounds with high DBPFP. The SIX/ILCA/CMF process resulted in additional removals of DOC, UVA, THMFP, HAAFP and brominated DBPs of 50, 62, 62, 62% and 47% respectively compared with conventional treatment. Copyright © 2015. Published by Elsevier Ltd.

  7. Bladder perforation owing to a unipolar coagulating device.

    PubMed

    Pakter, J; Budnick, L D

    1981-09-15

    A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.

  8. Mannose-binding lectin and its associated proteases (MASPs) mediate coagulation and its deficiency is a risk factor in developing complications from infection, including disseminated intravascular coagulation

    PubMed Central

    Takahashi, Kazue; Chang, Wei-Chuan; Takahashi, Minoru; Pavlov, Vasile; Ishida, Yumi; La Bonte, Laura; Shi, Lei; Fujita, Teizo; Stahl, Gregory L.; Van Cott, Elizabeth M.

    2010-01-01

    The first line of host defense is the innate immune system that includes coagulation factors and pattern recognition molecules, one of which is mannose-binding lectin (MBL). Previous studies have demonstrated that MBL deficiency increases susceptibility to infection. Several mechanisms are associated with increased susceptibility to infection, including reduced opsonophagocytic killing and reduced lectin complement pathway activation. In this study, we demonstrate that MBL and MBL-associated serine protease (MASP)-1/3 together mediate coagulation factor-like activities, including thrombin-like activity. MBL and/or MASP-1/3 deficient hosts demonstrate in vivo evidence that MBL and MASP-1/3 are involved with hemostasis following injury. Staphylococcus aureus infected MBL null mice developed disseminated intravascular coagulation (DIC), which was associated with elevated blood IL-6 levels (but not TNF-α and multi-organ inflammatory responses). Infected MBL null mice also develop liver injury. These findings suggest that MBL deficiency may manifest into DIC and organ failure during infectious diseases. PMID:20399528

  9. The Impact of Potassium Manganate (VII) on the Effectiveness of Coagulation in the Removal of Iron and Manganese from Groundwater with an Increased Content of Organic Substances

    NASA Astrophysics Data System (ADS)

    Krupińska, Izabela

    2017-12-01

    The article presents the results of studies concerning the impact of the method of Fe(II) ion oxidisation (dissolved oxygen and potassium manganate (VII)) on the effectiveness of coagulation in the removal of iron and manganese from groundwater with an increased content of organic substances. The efficiencies of two coagulants were compared: aluminium sulphate (VI) and polyaluminium chloride (Flokor 1.2A). Among the used methods of iron (II) oxidisation, the best effects have been achieved by potassium manganate (VII) because one of the oxidation products was manganese oxide (IV) precipitating from water. Better results in purifying the water were obtained with the use of a prehydrolysed coagulant Flokor 1.2 A than aluminium sulphate (VI).

  10. Multifrequency acoustics as a probe of mesoscopic blood coagulation dynamics

    NASA Astrophysics Data System (ADS)

    Ganesan, Adarsh; Rajendran, Gokulnath; Ercole, Ari; Seshia, Ashwin

    2016-08-01

    Coagulation is a complex enzymatic polymerisation cascade. Disordered coagulation is common in medicine and may be life-threatening yet clinical assays are typically bulky and/or provide an incomplete picture of clot mechanical evolution. We present the adaptation of an in-plane acoustic wave device: quartz crystal microbalance with dissipation at multiple harmonics to determine the time-evolution of mesoscale mechanical properties of clot formation in vitro. This approach is sensitive to changes in surface and bulk clot structure in various models of induced coagulopathy. Furthermore, we are able to show that clot formation at surfaces has different kinetics and mechanical strength to that in the bulk, which may have implications for the design of bioprosthetic materials. The "Multifrequency acoustics" approach thus enables unique capability to portray biological processes concerning blood coagulation.

  11. Dielectric coagulometry: a new approach to estimate venous thrombosis risk.

    PubMed

    Hayashi, Yoshihito; Katsumoto, Yoichi; Omori, Shinji; Yasuda, Akio; Asami, Koji; Kaibara, Makoto; Uchimura, Isao

    2010-12-01

    We present dielectric coagulometry as a new technique to estimate the risk of venous thrombosis by measuring the permittivity change associated with the blood coagulation process. The method was first tested for a simple system of animal erythrocytes suspended in fibrinogen solution, where the coagulation rate was controlled by changing the amount of thrombin added to the suspension. Second, the method was applied to a more realistic system of human whole blood, and the inherent coagulation process was monitored without artificial acceleration by a coagulation initiator. The time dependence of the permittivity at a frequency around 1 MHz showed a distinct peak at a time that corresponds to the clotting time. Our theoretical modeling revealed that the evolution of heterogeneity and the sedimentation in the system cause the peak of the permittivity.

  12. Synthesis of Phosphatidylserine and Its Stereoisomers: Their Role in Activation of Blood Coagulation.

    PubMed

    Mallik, Suman; Prasad, Ramesh; Bhattacharya, Anindita; Sen, Prosenjit

    2018-05-10

    Natural phosphatidylserine (PS), which contains two chiral centers, enhances blood coagulation. However, the process by which PS enhanced blood coagulation is not completely understood. An efficient and flexible synthetic route has been developed to synthesize all of the possible stereoisomers of PS. In this study, we examined the role of PS chiral centers in modulating the activity of the tissue factor (TF)-factor VIIa coagulation initiation complex. Full length TF was relipidated with phosphatidylcholine, and the synthesized PS isomers were individually used to estimate the procoagulant activity of the TF-FVIIa complex via a FXa generation assay. The results revealed that the initiation complex activity was stereoselective and had increased sensitivity to the configuration of the PS glycerol backbone due to optimal protein-lipid interactions.

  13. Optimization of composite coagulant made from polyferric chloride and tapioca starch in landfill leachate treatment

    NASA Astrophysics Data System (ADS)

    Shaylinda, M. Z. N.; Hamidi, A. A.; Mohd, N. A.; Ariffin, A.; Irvan, D.; Hazreek, Z. A. M.; Nizam, Z. M.

    2018-04-01

    In this research, the performance of polyferric chloride and tapioca flour as composite coagulants for partially stabilized leachate was investigated. Response surface methodology (RSM) was used to optimize the coagulation and flocculation process of partially stabilized leachate. Central composite design a standard design tool in RSM was applied to evaluate the interactions and effects of dose and pH. Dose 0.2 g/L Fe and pH 4.71 were the optimum value suggested by RSM. Experimental test based on the optimum condition, resulted in 95.9%, 94.6% and 50.4% of SS, color and COD removals, respectively. The percentage difference recorded between experimental and model responses was <5%. Therefore, it can be concluded that RSM was an appropriate optimization tool for coagulation and flocculation process.

  14. Surgical Coagulator With Carbon Dioxide Laser For Gynecology

    NASA Astrophysics Data System (ADS)

    Wolinski, Wieslaw; Kazmirowski, Antoni; Korobowicz, Witold; Olborski, Zbigniew

    1987-10-01

    The technical data and parameters of the CO2 surgical laser for gynecology are given. Coagulator was designed and constructed in Institute of Microelectronics and Optoelectronics Warsaw Technical University.

  15. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  16. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  17. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  18. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  19. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  20. Development of Polymeric Films with Piezoelectrical Properties from Polypeptides; Low, Odd Nylons; or Polyureas.

    DTIC Science & Technology

    1987-09-01

    coagulants selected for this investigation included benzene, carbon tetrachloride, ethyl acetate, isopropanol, and toluene. The nylon 3 solution was cast...nylon 3 dope when benzene or carbon tetrachloride was used as the coagulant, but a film rapidly formed when isopropanol was used as the coagulant...anhydride was removed at reduced pressure, and the product was distilled (bp 85 to 88 °C, 3 mm). A small amount of sodium bicarbonate was added to the

  1. The use of aluminum oxychlorides to coagulate water having high content of organic impurities and low alkalinity

    NASA Astrophysics Data System (ADS)

    Evsyutin, A. V.; Boglovskii, A. V.

    2007-07-01

    Results from laboratory investigations and industrial tests of the coagulation of source water at the Pskov district power station are presented. It is shown that the source water may not be alkalified if it is treated with aluminum oxychlorides. As a result, the clarified water becomes less corrosive and a lower salt load is placed on water treatment plants as compared with the case when aluminum sulfate is used for coagulation.

  2. Fibrinopeptide A blood test

    MedlinePlus

    ... problems with blood clotting such as disseminated intravascular coagulation ( DIC ). Certain types of leukemia are associated with ... be a sign of: Cellulitis DIC (disseminated intravascular coagulation) Leukemia at the time of diagnosis, during early ...

  3. The immediate and late effects of thyroid hormone (triiodothyronine) on murine coagulation gene transcription.

    PubMed

    Salloum-Asfar, Salam; Boelen, Anita; Reitsma, Pieter H; van Vlijmen, Bart J M

    2015-01-01

    Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine (T3) and thyroxine (T4) production. Under these conditions, the impact of exogenous T3 on plasma coagulation, and hepatic and vessel-wall-associated coagulation gene transcription was studied in a short- (4 hours) and long-term (14 days) setting. Comparing euthyroid conditions (normal mice), with hypothyroidism (conditions of a shortage of thyroid hormone) and those with replacement by incremental doses of T3, dosages of 0 and 0.5 μg T3/mouse/day were selected to study the impact of T3 on coagulation gene transcription. Under these conditions, a single injection of T3 injection increased strongly hepatic transcript levels of the well-characterized T3-responsive genes deiodinase type 1 (Dio1) and Spot14 within 4 hours. This coincided with significantly reduced mRNA levels of Fgg, Serpinc1, Proc, Proz, and Serpin10, and the reduction of the latter three persisted upon daily treatment with T3 for 14 days. Prolonged T3 treatment induced a significant down-regulation in factor (F) 2, F9 and F10 transcript levels, while F11 and F12 levels increased. Activity levels in plasma largely paralleled these mRNA changes. Thbd transcript levels in the lung (vessel-wall-associated coagulation) were significantly up-regulated after a single T3 injection, and persisted upon prolonged T3 exposure. Two-week T3 administration also resulted in increased Vwf and Tfpi mRNA levels, whereas Tf levels decreased. These data showed that T3 has specific effects on coagulation, with Fgg, Serpinc1, Proc, Proz, Serpin10 and Thbd responding rapidly, making these likely direct thyroid hormone receptor targets. F2, F9, F10, F11, F12, Vwf, Tf and Tfpi are late responding genes and probably indirectly modulated by T3.

  4. Genetic parameters for milk coagulation properties in Estonian Holstein cows.

    PubMed

    Vallas, M; Bovenhuis, H; Kaart, T; Pärna, K; Kiiman, H; Pärna, E

    2010-08-01

    The objective of this study was to estimate heritabilities and repeatabilities for milk coagulation traits [milk coagulation time (RCT) and curd firmness (E(30))] and genetic and phenotypic correlations between milk yield and composition traits (milk fat percentage and protein percentage, urea, somatic cell count, pH) in first-lactation Estonian Holstein dairy cattle. A total of 17,577 test-day records from 4,191 Estonian Holstein cows in 73 herds across the country were collected during routine milk recordings. Measurements of RCT and E(30) determined with the Optigraph (Ysebaert, Frepillon, France) are based on an optical signal in the near-infrared region. The cows had at least 3 measurements taken during the period from April 2005 to January 2009. Data were analyzed using a repeatability animal model. There was substantial variation in milk coagulation traits with a coefficient of variation of 27% for E(30) and 9% for the log-transformed RCT. The percentage of variation explained by herd was 3% for E(30) and 4% for RCT, suggesting that milk coagulation traits are not strongly affected by herd conditions (e.g., feeding). Heritability was 0.28 for RCT and 0.41 for E(30), and repeatability estimates were 0.45 and 0.50, respectively. Genetic correlation between both milk coagulation traits was negligible, suggesting that RCT and E(30) have genetically different foundations. Milk coagulation time had a moderately high positive genetic (0.69) and phenotypic (0.61) correlation with milk pH indicating that a high pH is related to a less favorable RCT. Curd firmness had a moderate positive genetic (0.48) and phenotypic (0.45) correlation with the protein percentage. Therefore, a high protein percentage is associated with favorable curd firmness. All reported genetic parameters were statistically significantly different from zero. Additional univariate random regression analysis for milk coagulation traits yielded slightly higher average heritabilities of 0.38 and 0.47 for RCT and E(30) compared with the heritabilities of the repeatability model. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Coagulation parameters in copperhead compared to other Crotalinae envenomation: secondary analysis of the F(ab')2 versus Fab antivenom trial.

    PubMed

    Gerardo, Charles J; Vissoci, Joao R Nickenig; Brown, Michael W J; Bush, Sean P

    2017-02-01

    Coagulation derangements in copperhead envenomation are considered less severe than other crotaline envenomations, resulting in recommendations to limit both coagulation testing and antivenom treatment. A prospective, blinded, multicenter, randomized clinical trial comparing the effectiveness of F(ab') 2 versus Fab antivenom in crotaline envenomation patients was completed in 2011. We determined the difference between coagulation parameters in copperhead compared to other crotaline envenomations. We performed a post hoc analysis comparing the coagulation parameters (platelets and fibrinogen) prospectively obtained in the aforementioned trial. All the patients received antivenom in one of three treatment arms [F(ab') 2 with maintenance, F(ab') 2 with placebo maintenance, or Fab with maintenance]. Coagulation parameters were measured at pretreatment baseline, during acute hospitalization, day 5, day 8, and day 15 post-envenomation. Mean platelet count and fibrinogen levels for the copperhead and other crotaline groups were compared. The platelet and fibrinogen point estimates with distribution are presented graphically over time. 122 patients were enrolled in the study. There were 22 patients with copperhead envenomation, 93 with other crotaline envenomations, and 7 that could not be definitively determined. The mean age was 42 (SD 20) years. There was a minor pretreatment difference in mean baseline platelet count between the copperhead group (246 × 109/L 95% CI 215, 277) compared to other crotaline envenomation patients (184 × 109/L 95% CI 167, 202). There was a modest pretreatment difference in mean fibrinogen level between copperhead patients (345 mg/dL 95% CI 277, 415) and other crotaline patients (261mg/dL 95% CI 241, 281). Pretreatment coagulation parameter means were normal and converged post treatment. On average, copperhead envenomations have less severe initial coagulation derangements. However, in mild envenomations, differences in laboratory values are minimal and there is substantial variation in individual patients regardless of species. Species alone should not be used to determine the need for laboratory testing or treatment in crotaline snakebite.

  6. Comprehensive reuse of drinking water treatment residuals in coagulation and adsorption processes.

    PubMed

    Jung, Kyung-Won; Hwang, Min-Jin; Park, Dae-Seon; Ahn, Kyu-Hong

    2016-10-01

    While drinking water treatment residuals (DWTRs) inevitably lead to serious problems due to their huge amount of generation and limitation of landfill sites, their unique properties of containing Al or Fe contents make it possible to reuse them as a beneficial material for coagulant recovery and adsorbent. Hence, in the present study, to comprehensively handle and recycle DWTRs, coagulant recovery from DWTRs and reuse of coagulant recovered residuals (CRs) were investigated. In the first step, coagulant recovery from DWTRs was conducted using response surface methodology (RSM) for statistical optimization of independent variables (pH, solid content, and reaction time) on response variable (Al recovery). As a result, a highly acceptable Al recovery of 97.5 ± 0.4% was recorded, which corresponds to 99.5% of the predicted Al recovery. Comparison study of recovered and commercial coagulant from textile wastewater treatment indicated that recovered coagulant has reasonable potential for use in wastewater treatment, in which the performance efficiencies were 68.5 ± 2.1% COD, 97.2 ± 1.9% turbidity, and 64.3 ± 1.0% color removals at 50 mg Al/L. Subsequently, in a similar manner, RSM was also applied to optimize coagulation conditions (Al dosage, initial pH, and reaction time) for the maximization of real cotton textile wastewater treatment in terms of COD, turbidity, and color removal. Overall performance revealed that the initial pH had a remarkable effect on the removal performance compared to the effects of other independent variables. This is mainly due to the transformation of metal species form with increasing or decreasing pH conditions. Finally, a feasibility test of CRs as adsorbent for phosphate adsorption from aqueous solution was conducted. Adsorption equilibrium of phosphate at different temperatures (10-30 °C) and initial levels of pH (3-11) indicated that the main mechanisms of phosphate adsorption onto CRs are endothermic and chemical precipitation; the surfaces are energetically heterogeneous for adsorbing phosphate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. What Is Disseminated Intravascular Coagulation?

    MedlinePlus

    ... leading to DIC. These diseases and conditions include: Sepsis (an infection in the bloodstream) Surgery and trauma ... intravascular coagulation (DIC). These diseases and conditions include: Sepsis (an infection in the bloodstream) Surgery and trauma ...

  8. Genetics Home Reference: prekallikrein deficiency

    MedlinePlus

    ... a role in a process called the intrinsic coagulation pathway (also called the contact activation pathway). This ... functional plasma kallikrein, which likely impairs the intrinsic coagulation pathway. Researchers suggest that this lack (deficiency) of ...

  9. Study of coagulation processes of selected humic acids under copper ions influence*

    NASA Astrophysics Data System (ADS)

    Boguta, Patrycja; Sokolowska, Zofia

    2013-04-01

    Humic acids have limited sorption capacity and big dose of metal or other mineral component which can be sorbed on humic acids, can cause saturation of negative, surface charge of humic acids leading to destabilization of dissolved humic acids compounds. Destabilisation can be observed as coagulation and floculation proces of humic acids. However there are a lot of mechanisms which causing precipitation of humic acids. Thereby, in order to full description of coagulation process, different methods should be applied. Ordinarily, humic acids coagulation is studied by measurement of absorbance, transmittance or carbon loss in solution. Meanwhile, very significant information is also variation of metal content in soil solution and information whether metal goes to precipitate together with humic acids or stays in dissolved form in solution. So, that, from one side, processes of stronger accumulation of metal can lead to soil degradation and micronutrient deficiency for plants. However, there is also possibility to stay metal in solution in toxic and bioavailable form for plants. Main aim of this paper was to study coagulation process of different humic acids extracted from mucking peats under copper ions influence at adjusted pH to 5. In order to this, four peaty-muck soils were taken from selected places in east part of Poland (meadows and river valleys). These soils differed by humification degree, secondary transformation, density and pH. At next step, humic acids were extracted from soils using sodium hydroxide (NaOH) extractant. After exact purification by washing with HF-HCl mixture and water, humic acids were liofilized. Solutions of humic acids were prepared at concentration 40 mg/dm3 with addition of different amount of copper ions to obtain final concentration of Cu(II) ranged from 0-40mg/dm3. After 24 hours solutions were investigated using measurements of absorbance at 470nm (UV-VIS spectrometer Jasco V-530), measurements of organic carbon in solution (carbon analyzer: Multi NC2000, Analityk Jena) and measurements of copper content in solution (atomic absorption spectrometer: Contraa300, Analityk Jena). On the base of obtained results initial and end point of coagulation was determined for each of humic acids. Results showed that coagulation points differed for different humic acids and it was probably depended on sorption possibilities. Coagulation points determined from UV-VIS measurements overlapped with points from carbon measurement. Loss of carbon during coagulation was almost total but loss of copper in solution during humic acid coagulation was much smaller and did not cover exactly points of carbon precipitation. So that, coagulation of humic acids under copper influence could resulted from both bonding of metal by functional groups and creating complexes and also from increasing ionic strength. Important is that organic carbon went to insoluble form and copper stayed in movable compounds. Such studies and conclusions coming from them, can be very important from ecological side. *This work was partly supported by the National Science Centre in Poland, grant No. UMO-2011/03/N/NZ9/04239.

  10. Mathematical Modeling of Intravascular Blood Coagulation under Wall Shear Stress

    PubMed Central

    Rukhlenko, Oleksii S.; Dudchenko, Olga A.; Zlobina, Ksenia E.; Guria, Georgy Th.

    2015-01-01

    Increased shear stress such as observed at local stenosis may cause drastic changes in the permeability of the vessel wall to procoagulants and thus initiate intravascular blood coagulation. In this paper we suggest a mathematical model to investigate how shear stress-induced permeability influences the thrombogenic potential of atherosclerotic plaques. Numerical analysis of the model reveals the existence of two hydrodynamic thresholds for activation of blood coagulation in the system and unveils typical scenarios of thrombus formation. The dependence of blood coagulation development on the intensity of blood flow, as well as on geometrical parameters of atherosclerotic plaque is described. Relevant parametric diagrams are drawn. The results suggest a previously unrecognized role of relatively small plaques (resulting in less than 50% of the lumen area reduction) in atherothrombosis and have important implications for the existing stenting guidelines. PMID:26222505

  11. IgMk paraprotein from gammopathy patient can bind to cardiolipin and interfere with coagulation assay: a case report.

    PubMed

    Wu, Xin-Yao; Yin, Yu-Feng; Teng, Jia-Lin; Zhang, Li-Wei; Yang, Cheng-de

    2017-06-23

    The monoclonal gammopathies are a group of plasma-cell proliferative disorders characterized by the secretion of monoclonal immunoglobulin (M protein or paraprotein). Some rare cases have revealed the specific affinity of paraprotein as autoantibody. Here we report a patient with monoclonal gammopathy of undetermined significance (MGUS) accompanied by a remarkable increase of anticardiolipin antibody (aCL) and an extensively decreased coagulation factor activity, however, without any clinical signs of antiphospholipid syndrome (APS) and bleeding. Our further investigation indicated that IgMκ paraprotein of this patient possessed an antibody activity against phospholipids so as to bind to cardiolipin and interfere with coagulation assay in vitro. This case might be indicative that an abnormality of coagulation tests, disturbed by IgMκ paraprotein, does not predict a risk of bleeding in this patient.

  12. Antithrombin, an Important Inhibitor in Blood Clots.

    PubMed

    Zhu, Ying; Cong, Qing-Wei; Liu, Yue; Wan, Chun-Ling; Yu, Tao; He, Guang; He, Lin; Cai, Lei; Chou, Kuo-Chen

    2016-01-01

    Blood coagulation is healthy and lifesaving because it can stop bleeding. It can, however, be a troublemaker as well, causing serious medical problems including heart attack and stroke. Body has complex blood coagulation cascade to modulate the blood clots. In the environment of plasma, the blood coagulation cascade is regulated by antithrombin, which is deemed one of the most important serine protease inhibitors. It inhibits thrombin; it can inhibit factors IXa and Xa as well. Interestingly, its inhibitory ability will be significantly increased with the existence of heparin. In this minireview paper, we are to summarize the structural features of antithrombin, as well as its heparin binding modes and anti-coagulation mechanisms, in hopes that the discussion and analysis presented in this paper can stimulate new strategies to find more effective approaches or compounds to modulate the antithrombin.

  13. Reexamining the functions of zinc sulfate as a selective depressant in differential sulfide flotation--the role of coagulation.

    PubMed

    Cao, Mingli; Liu, Qi

    2006-09-15

    Zinc sulfate is a well-known selective depressant for zinc sulfide minerals such as sphalerite during the flotation of complex Cu-Pb-Zn sulfide ores. It deactivates sphalerite flotation by substituting the activating metal ions, and depresses sphalerite flotation by forming hydrophilic coatings of zinc hydroxyl species on sphalerite surfaces. However, we recently observed that zinc sulfate could also induce coagulation of fine sphalerite particles and such coagulation significantly reduced the mechanical entrainment of the fine sphalerite. Therefore, it seems that the effectiveness of zinc sulfate as a selective sphalerite depressant is not only due to its ability to make mineral surface hydrophilic, which reduces genuine flotation, but also due to its ability to coagulate the mineral, which reduces mechanical entrainment. Zinc sulfate is a "dual function" selective flotation depressant.

  14. The use of the Kelor Seeds (Moringa oleifera) as alternative coagulant in waste delivery process of textile industrial waste

    NASA Astrophysics Data System (ADS)

    Rambe, AM; Pandia, S.; Ginting, MHS; Tambun, R.; Haryanto, B.

    2018-02-01

    This research is to know the influence of moringa seed as coagulant, pH of liquid waste textile industry (jeans wash), size of moringa seed particles to decrease of turbidity percentage. Measurements were made to Total Suspended Solid, Color Rate and Chemical Oxygen Demand for wastewater textile industry by coagulation - flocculation method. Variables of this study were conducted on dosage of moringa, with particle size 212 mesh. The results showed that moringa seeds as coagulant dose optimum is 1250 mg/L for the textile industry wastewater at pH 7.8. Moringa seed powder is about 212 mesh with a dose of 1250 mg/L can lower the turbidity of 77.77%, Total Suspended Solid amounted to 83.69% and Chemical Oxygen Demand amounted to 75.86%.

  15. Wetlands receiving water treated with coagulants improve water quality by removing dissolved organic carbon and disinfection byproduct precursors.

    PubMed

    Hansen, Angela M; Kraus, Tamara E C; Bachand, Sandra M; Horwath, William R; Bachand, Philip A M

    2018-05-01

    Constructed wetlands are used worldwide to improve water quality while also providing critical wetland habitat. However, wetlands have the potential to negatively impact drinking water quality by exporting dissolved organic carbon (DOC) that upon disinfection can form disinfection byproducts (DBPs) like trihalomethanes (THMs) and haloacetic acids (HAAs). We used a replicated field-scale study located on organic rich soils in California's Sacramento-San Joaquin Delta to test whether constructed flow-through wetlands which receive water high in DOC that is treated with either iron- or aluminum-based coagulants can improve water quality with respect to DBP formation. Coagulation alone removed DOC (66-77%) and THM (67-70%) precursors, and was even more effective at removing HAA precursors (77-90%). Passage of water through the wetlands increased DOC concentrations (1.5-7.5mgL -1 ), particularly during the warmer summer months, thereby reversing some of the benefits from coagulant addition. Despite this addition, water exiting the wetlands treated with coagulants had lower DOC and DBP precursor concentrations relative to untreated source water. Benefits of the coagulation-wetland systems were greatest during the winter months (approx. 50-70% reduction in DOC and DBP precursor concentrations) when inflow water DOC concentrations were higher and wetland DOC production was lower. Optical properties suggest DOC in this system is predominantly comprised of high molecular weight, aromatic compounds, likely derived from degraded peat soils. Published by Elsevier B.V.

  16. Structural bioinformatics: methods, concepts and applications to blood coagulation proteins.

    PubMed

    Villoutreix, Bruno O

    2002-06-01

    Structural and theoretical analyses of proteins are central to the understanding of complex molecular mechanisms and are fundamental to the drug discovery process. Computational techniques yield useful insights into an ever-wider range of biomolecular systems. Protein three-dimensional structures and molecular functions can be predicted in some circumstances, while experimental structures can be analyzed in depth via such computational approaches. Non-covalent binding of biomolecules can be understood by considering structural, thermodynamic and kinetic issues, and theoretical simulations of such events can be attempted. The central role of electrostatic interactions with regard to protein function, structure and stability has been investigated and some electrostatic properties can be modeled theoretically. Computer methods thus help to prioritize, design, analyze and rationalize biochemical experiments. Cardiovascular diseases and associated blood coagulation disorders are leading causes of death worldwide. Blood coagulation involves more than 30 proteins that interact specifically with various degrees of affinity. Many of these molecules can also bind transiently to phospholipid surfaces. Numerous point mutations in the genes of coagulation proteins and regulators have been identified. Understanding the coagulation cascade, its regulation and the impact of mutations is required for the development of new therapies and diagnostic tools. In this review, we describe concepts and methods pertaining to the field of structural bioinformatics. We provide examples of applications of these approaches to blood coagulation proteins and show that such studies can give insights about molecular mechanisms contributing to cardiovascular disease susceptibility.

  17. Mature landfill leachate treatment by coagulation/flocculation combined with Fenton and solar photo-Fenton processes.

    PubMed

    Amor, Carlos; De Torres-Socías, Estefanía; Peres, José A; Maldonado, Manuel I; Oller, Isabel; Malato, Sixto; Lucas, Marco S

    2015-04-09

    This work reports the treatment of a mature landfill leachate through the application of chemical-based treatment processes in order to achieve the discharge legal limits into natural water courses. Firstly, the effect of coagulation/flocculation with different chemicals was studied, evaluating the role of different initial pH and chemicals concentration. Afterwards, the efficiency of two different advanced oxidation processes for leachate remediation was assessed. Fenton and solar photo-Fenton processes were applied alone and in combination with a coagulation/flocculation pre-treatment. This physicochemical conditioning step, with 2 g L(-1) of FeCl3 · 6H2O at pH 5, allowed removing 63% of COD, 80% of turbidity and 74% of total polyphenols. Combining the coagulation/flocculation pre-treatment with Fenton reagent, it was possible to reach 89% of COD removal in 96 h. Moreover, coagulation/flocculation combined with solar photo-Fenton revealed higher DOC (75%) reductions than single solar photo-Fenton (54%). In the combined treatment (coagulation/flocculation and solar photo-Fenton), it was reached a DOC reduction of 50% after the chemical oxidation, with 110 kJ L(-1) of accumulated UV energy and a H2O2 consumption of 116 mM. Toxicity and biodegradability assays were performed to evaluate possible variations along the oxidation processes. After the combined treatment, the leachate under study presented non-toxicity but biodegradability increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Effect of coagulation on treatment of municipal wastewater reverse osmosis concentrate by UVC/H2O2.

    PubMed

    Umar, Muhammad; Roddick, Felicity; Fan, Linhua

    2014-02-15

    Disposal of reverse osmosis concentrate (ROC) is a growing concern due to potential health and ecological risks. Alum coagulation was investigated as pre-treatment for the UVC/H2O2 treatment of two high salinity ROC samples (ROC A and B) of comparable organic and inorganic content. Coagulation removed a greater fraction of the organic content for ROC B (29%) than ROC A (16%) which correlated well with the reductions of colour and A254. Although the total reductions after 60 min UVC/H2O2 treatment with and without coagulation were comparable, large differences in the trends of reduction were observed which were attributed to the different nature of the organic content (humic-like) of the samples as indicated by the LC-OCD analyses and different initial (5% and 16%) biodegradability. Coagulation and UVC/H2O2 treatment preferentially removed humic-like compounds which resulted in low reaction rates after UVC/H2O2 treatment of the coagulated samples. The improvement in biodegradability was greater (2-3-fold) during UVC/H2O2 treatment of the pre-treated samples than without pre-treatment. The target DOC residual (≤ 15 mg/L) was obtained after 30 and 20 min irradiation of pre-treated ROC A and ROC B with downstream biological treatment, corresponding to reductions of 55% and 62%, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Coagulation management in patients undergoing neurosurgical procedures.

    PubMed

    Robba, Chiara; Bertuetti, Rita; Rasulo, Frank; Bertuccio, Alessando; Matta, Basil

    2017-10-01

    Management of coagulation in neurosurgical procedures is challenging. In this contest, it is imperative to avoid further intracranial bleeding. Perioperative bleeding can be associated with a number of factors, including anticoagulant drugs and coagulation status but is also linked to the characteristic and the site of the intracranial disorder. The aim of this review will be to focus primarily on the new evidence regarding the management of coagulation in patients undergoing craniotomy for neurosurgical procedures. Antihemostatic and anticoagulant drugs have shown to be associated with perioperative bleeding. On the other hand, an increased risk of venous thromboembolism and hypercoagulative state after elective and emergency neurosurgery, in particular after brain tumor surgery, has been described in several patients. To balance the risk between thrombosis and bleeding, it is important to be familiar with the perioperative changes in coagulation and with the recent management guidelines for anticoagulated patients undergoing neurosurgical procedures, in particular for those taking new direct anticoagulants. We have considered the current clinical trials and literature regarding both safety and efficacy of deep venous thrombosis prophylaxis in the neurosurgical population. These were mainly trials concerning both elective surgical and intensive care patients with a poor grade intracranial bleed or multiple traumas with an associated severe traumatic brain injury (TBI). Coagulation management remains a major issue in patients undergoing neurosurgical procedures. However, in this field of research, literature quality is poor and further studies are necessary to identify the best strategies to minimize risks in this group of patients.

  20. Enhanced Coagulation-Flocculation Performance of Iron-Based Coagulants: Effects of PO4 3- and SiO3 2- Modifiers

    PubMed Central

    Teng, Houkai; Wang, Yili; Zhang, Yuxin; Zhao, Chuanliang; Liao, Yong

    2015-01-01

    PO4 3- and SiO3 2- are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants—polyferric phosphoric sulfate (PFPS), polysilicon ferric sulfate (PFSS), and polyferric sulfate (PFS) were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) and Scanning electron microscope (SEM). Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4 3- and SiO3 2-. Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond. PMID:26339902

  1. Plasmodium falciparum-infected erythrocytes induce Tissue Factor expression in endothelial cells and support the assembly of multimolecular coagulation complexes

    PubMed Central

    Francischetti, Ivo MB; Seydel, Karl B; Monteiro, Robson Q; Whitten, Richard O; Erexson, Cindy R; Noronha, Almério LL; Ostera, Graciela R.; Kamiza, Steve B; Molyneux, Malcolm E; Ward, Jerrold M; Taylor, Terrie E

    2010-01-01

    Summary Background Plasmodium falciparum malaria infects 300–500 million people every year causing 1–2 million deaths annually. Evidence of a coagulation disorder, activation of endothelial cells (EC) and increase in inflammatory cytokines are often present in malaria. Objectives We have asked whether parasitized red blood cells (pRBC) interaction with EC induces Tissue Factor expression in vitro and in vivo. The potential of phosphatidylserine-containing pRBC to support the assembly of blood coagulation complexes was also investigated. Results We demonstrate that mature forms of pRBC induce functional expression of tissue factor (TF) by endothelial cells (EC) in vitro with productive assembly of the extrinsic Xnase complex and initiation of the coagulation cascade. Late stage pRBC also support the prothrombinase and intrinsic Xnase complex formation in vitro, and may function as activated platelets in the amplification phase of the blood coagulation. Notably, postmortem brain sections obtained from P. falciparum-infected children who died from Cerebral Malaria and other causes display a consistent staining for TF in the EC. Conclusions These findings place TF expression by endothelium and the amplification of the coagulation cascade by pRBC and/or activated platelets as potentially critical steps in the pathogenesis of malaria. Furthermore, it may allow investigators to test other therapeutic alternatives targeting TF or modulators of EC function in the treatment of malaria and/or its complications. PMID:17002660

  2. Coagulation activation in autoimmune bullous diseases

    PubMed Central

    Marzano, A V; Tedeschi, A; Spinelli, D; Fanoni, D; Crosti, C; Cugno, M

    2009-01-01

    The main autoimmune blistering skin disorders are pemphigus vulgaris (PV) and bullous pemphigoid (BP). They differ in the inflammatory infiltrate, which is more intense in BP. Inflammation is known to activate coagulation in several disorders. Local and systemic activation of coagulation was evaluated in BP and PV. We studied 20 BP patients (10 active and 10 remittent), 23 PV patients (13 active and 10 remittent) and 10 healthy subjects. The coagulation markers prothrombin fragment F1+2 and D-dimer were measured by enzyme-immunoassays in plasma. The presence of tissue factor (TF), the main initiator of blood coagulation, was evaluated immunohistochemically in skin specimens from 10 patients with active PV, 10 patients with active BP and 10 controls. Plasma F1+2 and D-dimer levels were significantly high in active BP (P = 0·001), whereas in active PV the levels were normal. During remission, F1+2 and D-dimer plasma levels were normal in both BP and PV. TF immunoreactivity was found in active BP but neither in active PV nor in normal skin. TF reactivity scores were higher in active BP than in controls or active PV (P = 0·0001). No difference in TF scores was found between active PV and controls. BP is associated with coagulation activation, which is lacking in PV. This suggests that BP but not PV patients have an increased thrombotic risk. The observation that thrombotic complications occur more frequently in BP than in PV further supports this view. PMID:19737228

  3. Multifocal electroretinographical changes in monkeys with experimental ocular hypertension: a longitudinal study.

    PubMed

    Kremers, Jan; Doelemeyer, Arno; Polska, Elzbieta A; Moret, Fabrice; Lambert, Christian; Lambrou, George N

    2008-07-01

    To study the time course of changes in the multifocal electroretinograms (mfERG) in monkeys with experimental ocular hypertension (OHT). The mfERGs were recorded in 12 eyes out of 6 monkeys. Two baseline measurements were used to quantify the reproducibility, the inter-ocular and the inter-individual variability of the ERG signals. Thereafter, the trabeculum of one eye of each animal was laser-coagulated in one to three sessions to induce OHT. ERG measurements were repeated regularly in a period of 18 months and the changes in ERG waveforms were quantified. All animals displayed OHT (between 20 and 50 mmHg) in the laser-coagulated eyes. An ERG change was defined as the sum of differences during the first 90 ms between the laser-coagulated eye and the same eye before laser coagulation and between the laser-coagulated eye and the non-treated fellow eye. Three animals displayed significant changes for nearly all retinal areas and all stimulus conditions. The three remaining animals displayed significant changes only in one comparison, indicating very mild changes. The data indicate that a high stimulus contrast is more sensitive to detect changes, probably because of a better signal-to-noise ratio. Moreover, the comparisons with the fellow eye are more sensitive to detect changes than comparisons with the measurements before laser-coagulation. OHT does not always lead to ERG changes. Comparisons with fellow eyes using high contrast stimuli are more sensitive to detect changes related to OHT.

  4. Quality of oral anticoagulation with phenprocoumon in regular medical care and its potential for improvement in a telemedicine-based coagulation service--results from the prospective, multi-center, observational cohort study thrombEVAL.

    PubMed

    Prochaska, Jürgen H; Göbel, Sebastian; Keller, Karsten; Coldewey, Meike; Ullmann, Alexander; Lamparter, Heidrun; Jünger, Claus; Al-Bayati, Zaid; Baer, Christina; Walter, Ulrich; Bickel, Christoph; ten Cate, Hugo; Münzel, Thomas; Wild, Philipp S

    2015-01-23

    The majority of studies on quality of oral anticoagulation (OAC) therapy with vitamin K-antagonists are performed with short-acting warfarin. Data on long-acting phenprocoumon, which is frequently used in Europe for OAC therapy and is considered to enable more stable therapy adjustment, are scarce. In this study, we aimed to assess quality of OAC therapy with phenprocoumon in regular medical care and to evaluate its potential for optimization in a telemedicine-based coagulation service. In the prospective observational cohort study program thrombEVAL we investigated 2,011 patients from regular medical care in a multi-center cohort study and 760 patients from a telemedicine-based coagulation service in a single-center cohort study. Data were obtained from self-reported data, computer-assisted personal interviews, and laboratory measurements according to standard operating procedures with detailed quality control. Time in therapeutic range (TTR) was calculated by linear interpolation method to assess quality of OAC therapy. Study monitoring was carried out by an independent institution. Overall, 15,377 treatment years and 48,955 international normalized ratio (INR) measurements were analyzed. Quality of anticoagulation, as measured by median TTR, was 66.3% (interquartile range (IQR) 47.8/81.9) in regular medical care and 75.5% (IQR 64.2/84.4) in the coagulation service (P <0.001). Stable anticoagulation control within therapeutic range was achieved in 63.8% of patients in regular medical care with TTR at 72.1% (IQR 58.3/84.7) as compared to 96.4% of patients in the coagulation service with TTR at 76.2% [(IQR 65.6/84.7); P = 0.001)]. Prospective follow-up of coagulation service patients with pretreatment in regular medical care showed an improvement of the TTR from 66.2% (IQR 49.0/83.6) to 74.5% (IQR 62.9/84.2; P <0.0001) in the coagulation service. Treatment in the coagulation service contributed to an optimization of the profile of time outside therapeutic range, a 2.2-fold increase of stabile INR adjustment and a significant decrease in TTR variability by 36% (P <0.001). Quality of anticoagulation with phenprocoumon was comparably high in this real-world sample of regular medical care. Treatment in a telemedicine-based coagulation service substantially improved quality of OAC therapy with regard to TTR level, frequency of stable anticoagulation control, and TTR variability. ClinicalTrials.gov, unique identifier NCT01809015, March 8, 2013.

  5. Turbulent coagulation of particles smaller than the length scales of turbulence and equilibrium sorption of phenanthrene to clay: Implications for pollutant transport in the estuarine water column

    NASA Astrophysics Data System (ADS)

    Brunk, Brett Kenneth

    1997-11-01

    Pollutant and particle transport in estuaries is affected by a multitude of physical, chemical and biological processes. In this research the importance of equilibrium sorption and turbulent coagulation were studied. Sorption in estuaries was modeled using phenanthrene, bacterial extracellular polymer and kaolinite clay as surrogates for a hydrophobic organic pollutant, dissolved organic matter and inorganic suspended sediment, respectively. Experiments over a range of estuarine salinities showed that ionic strength had the largest effect on the extent of sorption, while the effect of extracellular polymer coatings on the mineral surfaces was insignificant. Further calculations using typical estuarine suspended sediment concentrations indicated that equilibrium sorption could not fully account for the solid/solution phase distribution of hydrophobic organic compounds in the estuarine water column. For particles that are small compared to the length scales of turbulence, the rate of coagulation is related to the dynamics of the smallest turbulent eddies since they have the highest shear rate. Experimental and theoretical effort focused on determining the coagulation rate of spherical particles in isotropic turbulence. A pair diffusion approximation valid for rapidly fluctuating flows was used to calculate the rate of coagulation in a randomly varying isotropic linear flow field. Dynamic simulations of particle coagulation in Gaussian turbulence were computed over a range of representative values of particle-particle interactions (i.e, hydrodynamic interactions and van der Waals attraction) and total strain (i.e., the product of the strain rate and its time scale). The computed coagulation rates for isotropic turbulence differed from analytical approximations valid at large and small total strain. As expected, particle interactions were found to be significant. Experimental measurements of coagulation in grid-generated turbulence were obtained by measuring the loss of singlet particles from an initially monodisperse suspension as a function of turbulence intensity. Model predictions based on the particle Hamaker constant and spatial distribution of turbulence in the reactor agreed well with the experiments without the use of any fitting parameters. The close agreement of simulations and observations indicate the numerical model has successfully captured the relevant physics that governs the aggregation of colloidal particles in turbulent flows. This work is the first successful description of turbulent coagulation. Given the ubiquity of turbulent suspensions in engineered and natural systems, the ability to quantitatively describe particle behavior under these conditions is expected to have considerable utility.

  6. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    PubMed

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  7. Hybrid coagulation-UF processes for spent filter backwash water treatment: a comparison studies for PAFCl and FeCl3 as a pre-treatment.

    PubMed

    Ebrahimi, Afshin; Amin, Mohammad Mehdi; Pourzamani, Hamidreza; Hajizadeh, Yaghoub; Mahvi, Amir Hossein; Mahdavi, Mokhtar; Rad, Mohammad Hassan Rabie

    2017-08-01

    In this study, the reclamation of clean water from spent filter backwash water (SFBW) was investigated through pilot-scale experiments. The pilot plant consisted of pre-sedimentation, coagulation, flocculation, clarification, and ultrafiltration (UF). Two coagulants of PAFCl and FeCl 3 were investigated with respect to their performance on treated SFBW quality and UF membrane fouling. At the optimum dose of PAFCl and FeCl 3 turbidity removal of 99.6 and 99.4% was attained, respectively. PAFCl resulted in an optimum UV 254 , TOC, and DOC removal of 80, 83.6, and 72.7%, respectively, and FeCl 3 caused the removal of those parameters by 76.7, 80.9, and 65.9%, respectively. PAFCl removed hydrophilic and transphilic constituent better than FeCl 3 , but FeCl 3 had, to some extent, higher affinities to a hydrophobic fraction. It was concluded that PAFCl showed a better coagulation performance in most cases and caused a lower membrane fouling rate compared to FeCl 3 . Finally, the treated SFBW with both coagulant-UF systems met the drinking water standards.

  8. Interaction between Paracoccidioides brasiliensis conidia and the coagulation system: involvement of fibrinogen

    PubMed Central

    Tamayo, Diana; Hernández, Orville; Muñoz-Cadavid, Cesar; Cano, Luz Elena; González, Angel

    2013-01-01

    The infectious process starts with an initial contact between pathogen and host. We have previously demonstrated that Paracoccidioides brasiliensis conidia interact with plasma proteins including fibrinogen, which is considered the major component of the coagulation system. In this study, we evaluated the in vitro capacity of P. brasiliensis conidia to aggregate with plasma proteins and compounds involved in the coagulation system. We assessed the aggregation of P. brasiliensis conidia after incubation with human serum or plasma in the presence or absence of anticoagulants, extracellular matrix (ECM) proteins, metabolic and protein inhibitors, monosaccharides and other compounds. Additionally, prothrombin and partial thromboplastin times were determined after the interaction of P. brasiliensis conidia with human plasma. ECM proteins, monosaccharides and human plasma significantly induced P. brasiliensis conidial aggregation; however, anticoagulants and metabolic and protein inhibitors diminished the aggregation process. The extrinsic coagulation pathway was not affected by the interaction between P. brasiliensis conidia and plasma proteins, while the intrinsic pathway was markedly altered. These results indicate that P. brasiliensis conidia interact with proteins involved in the coagulation system. This interaction may play an important role in the initial inflammatory response, as well as fungal disease progression caused by P. brasiliensis dissemination. PMID:23827999

  9. Prospective, randomized trial comparing diathermy excision and diathermy coagulation for symptomatic, prolapsed hemorrhoids.

    PubMed

    Quah, H M; Seow-Choen, F

    2004-03-01

    This study was designed to compare diathermy excision and diathermy coagulation in the treatment of symptomatic prolapsed piles. Forty-five consecutive patients were randomly assigned to diathermy excision hemorrhoidectomy (Group A, n = 25) and diathermy coagulation (Group B, n = 20) under general anesthesia. The median duration of surgery was ten minutes for both groups. There was no statistical difference in the severity of postoperative pain at rest between the two groups, but Group A patients felt less pain during defecation on the third postoperative day (median, 5 (interquartile range, 3-7) vs. 8 (4-9); P = 0.04) and on the sixth postoperative day (median, 5 (interquartile range, 2-6) vs. 9 (5-10); P = 0.02). There was, however, no statistical difference in postoperative oral analgesics use and patients' satisfaction scores between the two groups. Complication rates were similar except that diathermy coagulation tended to leave some residual skin components of external hemorrhoid especially in very large prolapsed piles. Group A patients resumed work earlier (mean, 12 (range, 4-20) vs. 17 (11-21) days); however, this was not statistically significant ( P = 0.1). Diathermy coagulation of hemorrhoids is a simple technique and may be considered in suitable cases.

  10. Influence of the Mixing Energy Consumption Affecting Coagulation and Floc Aggregation.

    PubMed

    Vadasarukkai, Yamuna S; Gagnon, Graham A

    2017-03-21

    The operational significance of energy-intensive rapid mixing processes remains unaddressed in coagulation and flocculation of insoluble precipitates (flocs), which play an important role in the removal of impurities from drinking water supplies. In this study, the influence of rapid mixing and associated mixing energy on floc aggregation was examined for a surface water source characterized by a high fraction of aquatic humic matter. Infrared spectral analyses showed that the colloidal complexes resulting from ligand exchange between iron and dissolved natural organic matter (DOM) were not substantially influenced by the mixing energy input. This signified that DOM removal by coagulation can be achieved at lower mixing intensity, thereby reducing energy consumption. In contrast, macroscopic investigations showed the coagulation mixing energy affected floc size distributions during the slow mixing stage in flocculation and, to some extent, their settling characteristics. The results from analysis of floc properties clearly showed that more mixing energy was expended than necessary in coagulation, which is typically designed at a high mixing intensity range of 600-1000 s -1 in treatment plants. The key findings from this study have practical implications to water utilities to strategically meet water quality goals while reducing energy demands.

  11. Edible bird’s nest attenuates procoagulation effects of high-fat diet in rats

    PubMed Central

    Yida, Zhang; Imam, Mustapha Umar; Ismail, Maznah; Ismail, Norsharina; Hou, Zhiping

    2015-01-01

    Edible bird’s nest (EBN) is popular in Asia, and has long been used traditionally as a supplement. There are, however, limited evidence-based studies on its efficacy. EBN has been reported to improve dyslipidemia, which is closely linked to hypercoagulation states. In the present study, the effects of EBN on high-fat diet- (HFD-) induced coagulation in rats were evaluated. Rats were fed for 12 weeks with HFD alone or in combination with simvastatin or EBN. Food intake was estimated, and weight measurements were made during the experimental period. After sacrifice, serum oxidized low-density lipoprotein (oxLDL), adiponectin, leptin, von willibrand factor, prostacyclin, thromboxane and lipid profile, and whole blood coagulation indices (bleeding time, prothrombin time, activated partial thromboplastin time, red blood count count, and platelet count) were estimated. Furthermore, hepatic expression of coagulation-related genes was evaluated using multiplex polymerase chain reaction. The results indicated that EBN could attenuate HFD-induced hypercholesterolemia and coagulation similar to simvastatin, partly through transcriptional regulation of coagulation-related genes. The results suggested that EBN has the potential for lowering the risk of cardiovascular disease-related hypercoagulation due to hypercholesterolemia. PMID:26251574

  12. Haem-assisted dityrosine-cross-linking of fibrinogen under non-thermal plasma exposure: one important mechanism of facilitated blood coagulation

    PubMed Central

    Ke, Zhigang; Huang, Qing

    2016-01-01

    Although blood coagulation facilitated by non-thermal plasma has been reported several years ago, the insight to the involved mechanisms is still rather limited. In this work, we report our discovery of a new mechanism for the haem-promoted blood-coagulation caused by non-thermal plasma treatment. The reason for the haem role is due to that its oxidized form, namely, hematin, can promote the dityrosine cross-linking of fibrinogen, the most important coagulation protein, to form a membrane-like layer on the surface of the treated blood with plasma exposure. Both haem and non-thermal-plasma generated hydrogen peroxide are requisite for the cross-linking process. We confirmed that fibrinogen can coordinate with the haem iron to form a protein-haem complex which shows pseudo-peroxidase activity, and in the presence of hydrogen peroxide, the complex can induce the dityrosine formation between fibrinogen molecules, leading to the fibrin network necessary for the blood coagulation. Understanding of such an underlying mechanism can be useful to guide more efficient application of non-thermal plasma in the management of hemostasis, thrombosis and etc. PMID:27229173

  13. Evaluation of plant-based natural coagulants for municipal wastewater treatment.

    PubMed

    Maurya, Sandhya; Daverey, Achlesh

    2018-01-01

    In this study, four plant-based natural coagulants (banana peel powder, banana stem juice, papaya seed powder and neem leaf powder) were evaluated for the removal of turbidity, chemical oxygen demand (COD) and total suspended solids (TSS) from municipal wastewater. The experiments were conducted at room temperature without adjusting the initial pH. The maximum turbidity removal was observed with banana peel powder (59.6%) at 0.4 g/L of dosage. Papaya seed powder and banana stem juice were the most effective for TSS removal (66.66%) and COD removal (66.67%), respectively. Significant linear relationships between turbidity and TSS ( R 2  = 0.67-0.88) and turbidity removals and COD removals ( R 2  = 0.68-0.8) were observed. Interestingly, all the natural coagulants tested in the study did not change the pH of the wastewater, which is an added advantage. FTIR analysis of banana peels revealed that functional groups such as carboxylic acid, hydroxyl and aliphatic amines might be responsible for promoting the coagulation-flocculation by neutralizing the charge on impurities in water. Overall, the results suggest the potential of low-cost natural coagulants in municipal wastewater treatment.

  14. Treatment of cooling tower blowdown water containing silica, calcium and magnesium by electrocoagulation.

    PubMed

    Liao, Z; Gu, Z; Schulz, M C; Davis, J R; Baygents, J C; Farrell, J

    2009-01-01

    This research investigated the effectiveness of electrocoagulation using iron and aluminium electrodes for treating cooling tower blowdown (CTB) waters containing dissolved silica (Si(OH)(4)), Ca(2 + ) and Mg(2 + ). The removal of each target species was measured as a function of the coagulant dose in simulated CTB waters with initial pH values of 5, 7, and 9. Experiments were also performed to investigate the effect of antiscaling compounds and coagulation aids on hardness ion removal. Both iron and aluminum electrodes were effective at removing dissolved silica. For coagulant doses < or =3 mM, silica removal was a linear function of the coagulant dose, with 0.4 to 0.5 moles of silica removed per mole of iron or aluminium. Iron electrodes were only 30% as effective at removing Ca(2 + ) and Mg(2 + ) as compared to silica. There was no measurable removal of hardness ions by aluminium electrodes in the absence of organic additives. Phosphonate based antiscaling compounds were uniformly effective at increasing the removal of Ca(2 + ) and Mg(2 + ) by both iron and aluminium electrodes. Cationic and amphoteric polymers used as coagulation aids were also effective at increasing hardness ion removal.

  15. Complement component 5 promotes lethal thrombosis

    PubMed Central

    Mizuno, Tomohiro; Yoshioka, Kengo; Mizuno, Masashi; Shimizu, Mie; Nagano, Fumihiko; Okuda, Tomoyuki; Tsuboi, Naotake; Maruyama, Shoichi; Nagamatsu, Tadashi; Imai, Masaki

    2017-01-01

    Extracellular histones promote platelet aggregation and thrombosis; this is followed by induction of coagulation disorder, which results in exhaustion of coagulation factors. Complement component 5 (C5) is known to be associated with platelet aggregation and coagulation system activation. To date, the pathological mechanism underlying liver injury has remained unclear. Here, we investigated whether C5 promotes liver injury associated with histone-induced lethal thrombosis. C5-sufficient and C5-deficient mice received single tail vein injections of purified, unfractionated histones obtained from calf thymus (45–75 μg/g). Subsequently, the mice were monitored for survival for up to 72 h. Based on the survival data, the 45 μg/g dose was used for analysis of blood cell count, liver function, blood coagulation ability, and promotion of platelet aggregation and platelet/leukocyte aggregate (PLA) production by extracellular histones. C5-deficient mice were protected from lethal thrombosis and had milder thrombocytopenia, consumptive coagulopathy, and liver injury with embolism and lower PLA production than C5-sufficient mice. These results indicate that C5 is associated with coagulation disorders, PLA production, and embolism-induced liver injury. In conclusion, C5 promotes liver injury associated with histone-induced lethal thrombosis. PMID:28205538

  16. The clouds of Venus. II - An investigation of the influence of coagulation on the observed droplet size distribution

    NASA Technical Reports Server (NTRS)

    Rossow, W. B.

    1977-01-01

    An approximate numerical technique is used to investigate the influence of coagulation, sedimentation and turbulent motions on the observed droplet size distribution in the upper layers of the Venus clouds. If the cloud mass mixing ratio is less than 0.000001 at 250 K or the eddy diffusivity throughout the cloud is greater than 1,000,000 sq cm per sec, then coagulation is unimportant. In this case, the observed droplet size distribution is the initial size distribution produced by the condensation of the droplets. It is found that all cloud models with droplet formation near the cloud top (e.g., a photochemical model) must produce the observed droplet size distribution by condensation without subsequent modification by coagulation. However, neither meteoritic or surface dust can supply sufficient nucleating particles to account for the observed droplet number density. If the cloud droplets are formed near the cloud bottom, the observed droplet size distribution can be produced solely by the interaction of coagulation and dynamics; all information about the initial size distribution is lost. If droplet formation occurs near the cloud bottom, the lower atmosphere of Venus is oxidizing rather than reducing.

  17. In vitro anti-thrombotic and anti-coagulant properties of blacklip abalone (Haliotis rubra) viscera hydrolysate.

    PubMed

    Suleria, Hafiz Ansar Rasul; Masci, Paul P; Addepalli, Rama; Chen, Wei; Gobe, Glenda C; Osborne, Simone A

    2017-07-01

    Abalone viscera contain sulphated polysaccharides with anti-thrombotic and anti-coagulant activities. In this study, a hydrolysate was prepared from blacklip abalone (Haliotis rubra) viscera using papain and bromelain and fractionated using ion exchange and size exclusion chromatography. Hydrolysates and fractions were investigated for in vitro thrombin inhibition mediated through heparin cofactor II (HCII) as well as anti-coagulant activity in plasma and whole blood. On the basis of sulphated polysaccharide concentration, the hydrolysate inhibited thrombin through HCII with an inhibitor concentration at 50% (IC50) of 16.5 μg/mL compared with 2.1 μg/mL for standard heparin. Fractionation concentrated HCII-mediated thrombin inhibition down to an IC50 of 1.8 μg/mL and improved anti-coagulant activities by significantly delaying clotting time. This study confirmed the presence of anti-thrombotic and anti-coagulant molecules in blacklip abalone viscera and demonstrated that these activities can be enriched with a simple chromatography regime. Blacklip abalone viscera warrant further investigation as a source of nutraceutical or functional food ingredients. Graphical abstract Schematic showing preparation of bioactive extracts and fractions from blacklip abalone.

  18. Soluble Proteins Form Film by the Treatment of Low Temperature Plasma

    NASA Astrophysics Data System (ADS)

    Ikehara, Sanae; Sakakita, Hajime; Ishikawa, Kenji; Akimoto, Yoshihiro; Nakanishi, Hayao; Shimizu, Nobuyuki; Hori, Masaru; Ikehara, Yuzuru

    2015-09-01

    It has been pointed out that low temperature plasma in atmosphere was feasible to use for hemostasis without heat injury. Indeed, earlier studies demonstrated that low temperature plasma played an important role to stimulate platelets to aggregate and turned on the proteolytic activities of coagulation factors, resulting in the acceleration of the natural blood coagulation process. On the other hands, our developed equips could immediately form clots upon the contact with plasma flair, while the histological appearance was different from natural coagulation. Based on these findings in formed clots, we sought to determine if plasma flair supplied by our devices was capable of forming film using a series of soluble proteins Following plasma treatment, films were formed from bovine serum albumin, and the other plasma proteins at physiological concentration. Analysis of trans-electron microscope demonstrated that plasma treatment generated small protein particles and made them fuse to be larger aggregations The combined results demonstrated that plasma are capable of aggregating soluble proteins and that platelets and coagulation factors are not necessary for plasma induced blood coagulation. Supported in part by Grants-in-Aid for Scientific Research on Priority Area (21590454, 24590498, and 24108006 to Y. I.).

  19. Host defense peptides of thrombin modulate inflammation and coagulation in endotoxin-mediated shock and Pseudomonas aeruginosa sepsis.

    PubMed

    Kalle, Martina; Papareddy, Praveen; Kasetty, Gopinath; Mörgelin, Matthias; van der Plas, Mariena J A; Rydengård, Victoria; Malmsten, Martin; Albiger, Barbara; Schmidtchen, Artur

    2012-01-01

    Gram-negative sepsis is accompanied by a disproportionate innate immune response and excessive coagulation mainly induced by endotoxins released from bacteria. Due to rising antibiotic resistance and current lack of other effective treatments there is an urgent need for new therapies. We here present a new treatment concept for sepsis and endotoxin-mediated shock, based on host defense peptides from the C-terminal part of human thrombin, found to have a broad and inhibitory effect on multiple sepsis pathologies. Thus, the peptides abrogate pro-inflammatory cytokine responses to endotoxin in vitro and in vivo. Furthermore, they interfere with coagulation by modulating contact activation and tissue factor-mediated clotting in vitro, leading to normalization of coagulation responses in vivo, a previously unknown function of host defense peptides. In a mouse model of Pseudomonas aeruginosa sepsis, the peptide GKY25, while mediating a modest antimicrobial effect, significantly inhibited the pro-inflammatory response, decreased fibrin deposition and leakage in the lungs, as well as reduced mortality. Taken together, the capacity of such thrombin-derived peptides to simultaneously modulate bacterial levels, pro-inflammatory responses, and coagulation, renders them attractive therapeutic candidates for the treatment of invasive infections and sepsis.

  20. Evaluation of carbofuran-mediated toxicity against human lymphocytes and red blood cells in simulated wastewater degraded by coagulation-flocculation.

    PubMed

    Saini, Roli; Kumar, Pradeep; Hira, Sumit Kumar; Manna, Partha Pratim

    2017-06-01

    Coagulation-flocculation in water treatment has been relied upon aluminum (Al) and iron (Fe) salts for treatment of contaminants present in source waters containing dissolved organic compounds. However, water quality deteriorates day by day which makes it urgent to improve the standards of the treatment procedure. Coagulation-flocculation-sedimentation performance of ferric chloride and alum was comparatively investigated for carbofuran treatment in simulated wastewater. Coagulation trails were performed in a jar test at several pH levels and coagulant doses to determine reduction efficiencies of carbofuran degradation and chemical oxygen demand (COD). Effect of carbofuran on proliferation, viability, and direct cytotoxicity was performed using human neuroblastoma cells U-87. Direct toxicity of carbofuran on human mononuclear cells and red blood cells (RBC) was also analyzed. Carbofuran and its derivatives were found to be relatively safe at low concentration (2-5 μM). However, at slightly higher concentration (8 μM), a moderate loss in viability and proliferative potential was observed. Taken together, these results suggest that carbofuran appears to be safe at moderate or low concentration with respect to viability of normal human lymphocytes and RBC.

  1. Experimental investigation and modeling of dissolved organic carbon removal by coagulation from seawater.

    PubMed

    Jeong, Sanghyun; Sathasivan, Arumugam; Kastl, George; Shim, Wang Geun; Vigneswaran, Saravanamuthu

    2014-01-01

    Coagulation removes colloidal matters and dissolved organic carbon (DOC) which can cause irreversible membrane fouling. However, how DOC is removed by coagulant is not well-known. Jar test was used to study the removal of hydrophobic and hydrophilic DOC fractions at various doses (0.5-8.0 mg-Fe(+3) L(-1)) of ferric chloride (FeCl3) and pH (5.0-9.0). Natural organic matter (NOM) in seawater and treated seawater were fractionated by liquid chromatography-organic carbon detector (LC-OCD). Compared to surface water, the removal of DOC in seawater by coagulation was remarkably different. Majority of DOC could be easily removed with very low coagulant dose (<5.0 mg-Fe(+3) L(-1)) and the removal efficiency did not vary with pH, but the DOC composition in treated water had significantly changed. Hydrophobic fraction (HB) was better removed at high pH while hydrophilic fraction (HF) was better removed at low pH. A modified model of Kastl et al. (2004) which assumed that the removal occurred by adsorption of un-dissociated compounds onto ferric hydroxide was formulated and successfully validated against the jar test data. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    PubMed

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  3. Cosmetic wastewater treatment by coagulation and advanced oxidation processes.

    PubMed

    Naumczyk, Jeremi; Bogacki, Jan; Marcinowski, Piotr; Kowalik, Paweł

    2014-01-01

    In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well - COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, 'OH radical scavengers' in the wastewater.

  4. Supplemental oxygen: ensuring its safe delivery during facial surgery.

    PubMed

    Reyes, R J; Smith, A A; Mascaro, J R; Windle, B H

    1995-04-01

    Electrosurgical coagulation in the presence of blow-by oxygen is a potential source of fire in facial surgery. A case report of a patient sustaining partial-thickness facial burns secondary to such a flash fire is presented. A fiberglass facial model is then used to study the variables involved in providing supplemental oxygen when an electrosurgical unit is employed. Oxygen flow, oxygen delivery systems, distance from the oxygen source, and coagulation current levels were varied. A nasal cannula and an adapted suction tubing provided the oxygen delivery systems on the model. Both the "displaced" nasal cannula and the adapted suction tubing ignited at a minimum coagulation level of 30 W, an oxygen flow of 2 liters/minute, and a linear distance of 5 cm from the oxygen source. The properly placed nasal cannula did not ignite at any combination of oxygen flow, coagulation current level, or distance from the oxygen source. Facial cutaneous surgery in patients provided supplemental oxygen should be practiced with caution when an electrosurgical unit is used for coagulation. The oxygen delivery systems adapted for use are hazardous and should not be used until their safety has been demonstrated.

  5. Analysis of radiation parameters to control the effects of Nd:YAG laser surgery on gastric malignancies

    NASA Astrophysics Data System (ADS)

    Pelayo-Fernández, M. L.; Fanjul-Vélez, F.; Salas-García, I.; Hernández-González, A.; Arce-Diego, J. L.

    2015-07-01

    Endoscopic laser surgery provides an advantageous alternative to Argon Plasma Coagulation, endoscopic tweezers or electro-ablation in gastroenterology that facilitates a selective ablation of stomach tumors with an additional hemostatic effect in the surrounding tissue. This coagulation effect can also be employed for the treatment of gastric ulcers. It is mandatory to control the laser parameters regardless of the desired effect, either cancerous tissue ablation or coagulation to prevent ulcerous bleeding, in order to avoid stomach wall perforation or an insufficient therapeutic outcome. Dosimetric models constitute an attractive tool to determine the proper light dose in order to offer a customized therapy planning that optimizes the treatment results. In this work, a model for Nd:YAG laser surgery is applied to predict both the coagulation zone in gastric ulcers and the removal in adenocarcinomas under different laser setups. Results show clear differences in the effective zone of the gastric malignancy affected by both coagulation and ablation. Therefore the current model could be employed in the clinical practice to plan the optimal laser beam parameters to treat a certain type of pathologic stomach tissue with variable morphology and without risk of perforation or undertreated parts.

  6. 40 CFR 141.715 - Microbial toolbox options for meeting Cryptosporidium treatment requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... criteria are in § 141.716(b). Pre Filtration Toolbox Options (3) Presedimentation basin with coagulation 0... separate granular media filtration stage if treatment train includes coagulation prior to first filter...

  7. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  8. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  9. 40 CFR 141.715 - Microbial toolbox options for meeting Cryptosporidium treatment requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... criteria are in § 141.716(b). Pre Filtration Toolbox Options (3) Presedimentation basin with coagulation 0... separate granular media filtration stage if treatment train includes coagulation prior to first filter...

  10. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  11. The Mechanisms of Coagulation.

    ERIC Educational Resources Information Center

    Kurtz, Richard; Jesty, Jolyon

    1994-01-01

    Several topics such as heart disease, strokes, biochemical reactions, blood components, and genetics can be related to blood clotting. Introduces a simple, safe and inexpensive hands-on demonstration using bovine (cattle) blood plasma of normal and abnormal coagulation. (ZWH)

  12. 40 CFR 141.64 - Maximum contaminant levels for disinfection byproducts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening or GAC10... Haloacetic acids (five) (HAA5) Enhanced coagulation or enhanced softening, plus GAC10; or nanofiltration with...

  13. CLARIFICATION OF POTOMAC RIVER WATER WITH CATIONIC POLYELECTROLYTES

    DTIC Science & Technology

    of normal amounts of chlorine, act effectively as a sole coagulant. It can replace a conventional metal salt in a system comprised of a solids-contact upflow type coagulation basin and a pressure- diatomite filter.

  14. Bullous pyoderma gangrenosum complicated by disseminated intravascular coagulation with subsequent myelodysplastic syndrome (chronic myelomonocytic leukemia).

    PubMed

    Rogalski, Christina; Paasch, Uwe; Glander, Hans-Jürgen; Haustein, Uwe-Frithjof

    2003-01-01

    A 33-year-old woman developed a bullous PG precursing a chronic myelomonocytic leukemia (CMML) complicated by life-threatening, disseminated, intravascular coagulation after administration of systemic corticosteroids in combination with immunosuppressant and antibiotic agents. Although the association between PG and leukemia, as well as the coincidence of disseminated intravascular coagulation (DIC) and leukemia, is well known, a premonitoring effect of PG in combination with DIC preceding the diagnosis of chronic myelomonocytic leukemia in the same patient has not been reported recently.

  15. Vitamin K: from coagulation to calcification.

    PubMed

    Paakkari, Ilari

    Vitamin K is not only essential for the synthesis of coagulation factors in the liver, but it also strengthens the bones and prevents calcification of the arteries. These effects are mediated through the same mechanism, i.e. carboxylation of Gla target proteins. The discovery of novel Gla proteins that are not associated with blood coagulation or calcium metabolism indicates that vitamin K has additional effects in the pancreas and the central nervous system, for example. As dietary supplements, vitamin K1 of plant origin and vitamins K2 of bacterial origin may exert different effects.

  16. Surface-mediated molecular events in material-induced blood-plasma coagulation

    NASA Astrophysics Data System (ADS)

    Chatterjee, Kaushik

    Coagulation and thrombosis persist as major impediments associated with the use of blood-contacting medical devices. We are investigating the molecular mechanism underlying material-induced blood-plasma coagulation focusing on the role of the surface as a step towards prospective development of improved hemocompatible biomaterials. A classic observation in hematology is that blood/blood-plasma in contact with clean glass surface clots faster than when in contact with many plastic surfaces. The traditional biochemical theory explaining the underlying molecular mechanism suggests that hydrophilic surfaces, like that of glass, are specific activators of the coagulation cascade because of the negatively-charged groups on the surface. Hydrophobic surfaces are poor procoagulants or essentially "benign" because they lack anionic groups. Further, these negatively-charged surfaces are believed to not only activate blood factor XII (FXII), the key protein in contact activation, but also play a cofactor role in the amplification and propagation reactions that ultimately lead to clot formation. In sharp contrast to the traditional theory, our investigations indicate a need for a paradigm shift in the proposed sequence of contact activation events to incorporate the role of protein adsorption at the material surfaces. These studies have lead to the central hypothesis for this work proposing that protein adsorption to hydrophobic surfaces attenuates the contact activation reactions so that poorly-adsorbent hydrophilic surfaces appear to be stronger procoagulants relative to hydrophobic surfaces. Our preliminary studies measuring the plasma coagulation response of activated FXII (FXIIa) on different model surfaces suggested that the material did not play a cofactor role in the processing of this enzyme dose through the coagulation pathway. Therefore, we focused our efforts on studying the mechanism of initial production of enzyme at the procoagulant surface. Calculations for the amounts of FXIIa generated at material surfaces in plasma using a mathematical model for measured coagulation responses indicate that the relative contributions of the individual pathways of enzyme generation are similar at both hydrophilic and hydrophobic surfaces, only the amounts of enzyme generated scale with surface energy and area of the activating surface. Further, from direct measurement of enzyme activation at test surfaces we observed that contact activation reactions are not specific to negatively-charged hydrophilic surfaces. Rather, the molecular interactions are attenuated at hydrophobic surfaces due to protein adsorption so that poorly-adsorbent hydrophilic surfaces exhibit an apparent specificity for contact activation reactions. Preliminary studies were preformed to assay the plasma coagulation response to low-fouling surfaces prepared by either grafting poly(ethylene glycol) chains or using zwitterions. Results indicate that poly(ethylene glycol)-modified surfaces are significantly weaker procoagulants than surfaces containing zwitterions underscoring a need to specifically evaluate the coagulation response despite similarities in observed protein adsorption to both surfaces. In summary, our studies demonstrate a need to incorporate protein-adsorption competition at procoagulant surfaces into the mechanism of contact activation to account for the observed moderation of FXII activation by blood proteins unrelated to the plasma coagulation cascade.

  17. Pretreatment of algae-laden and manganese-containing waters by oxidation-assisted coagulation: Effects of oxidation on algal cell viability and manganese precipitation.

    PubMed

    Lin, Jr-Lin; Hua, Lap-Cuong; Wu, Yuting; Huang, Chihpin

    2016-02-01

    Preoxidation is manipulated to improve performance of algae and soluble manganese (Mn) removal by coagulation-sedimentation for water treatment plants (WTPs) when large amount of soluble Mn presents in algae-laden waters. This study aimed to investigate the effects of preoxidation on the performance of coagulation-sedimentation for the simultaneous removal of algae and soluble Mn, including ionic and complexed Mn. NaOCl, ClO2, and KMnO4 were used to pretreat such algae-laden and Mn containing waters. The variation of algal cell viability, residual cell counts, and concentrations of Mn species prior to and after coagulation-sedimentation step were investigated. Results show that NaOCl dosing was effective in reducing the viability of algae, but precipitated little Mn. ClO2 dosing had a strongest ability to lower algae viability and oxidize ionic and complexed soluble Mn, where KMnO4 dosing oxidized ionic and complexed Mn instead of reducing the viability of cells. Preoxidation by NaOCl only improved the algae removal by sedimentation, whereas most of soluble Mn still remained. On the other hand, ClO2 preoxidation substantially improved the performance of coagulation-sedimentation for simultaneous removal of algae and soluble Mn. Furthermore, KMnO4 preoxidation did improve the removal of algae by sedimentation, but left significant residual Mn in the supernatant. Images from FlowCAM showed changes in aspect ratio (AR) and transparency of algae-Mn flocs during oxidation-assisted coagulation, and indicates that an effective oxidation can improve the removal of most compact algae-Mn flocs by sedimentation. It suggests that an effective preoxidation for reducing algal cell viability and the concentration of soluble Mn is a crucial step for upgrading the performance of coagulation-sedimentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Onset of Coagulation Function Recovery Is Delayed in Severely Injured Trauma Patients with Venous Thromboembolism.

    PubMed

    McCully, Belinda H; Connelly, Christopher R; Fair, Kelly A; Holcomb, John B; Fox, Erin E; Wade, Charles E; Bulger, Eileen M; Schreiber, Martin A

    2017-07-01

    Altered coagulation function after trauma can contribute to development of venous thromboembolism (VTE). Severe trauma impairs coagulation function, but the trajectory for recovery is not known. We hypothesized that enhanced, early recovery of coagulation function increases VTE risk in severely injured trauma patients. Secondary analysis was performed on data from the Pragmatic Randomized Optimal Platelet and Plasma Ratio (PROPPR) trial, excluding patients who died within 24 hours or were on pre-injury anticoagulants. Patient characteristics, adverse outcomes, and parameters of platelet function and coagulation (thromboelastography) were compared from admission to 72 hours between VTE (n = 83) and non-VTE (n = 475) patients. A p value < 0.05 indicates significance. Despite similar patient demographics, VTE patients exhibited hypercoagulable thromboelastography parameters and enhanced platelet function at admission (p < 0.05). Both groups exhibited hypocoagulable thromboelastography parameters, platelet dysfunction, and suppressed clot lysis (low clot lysis at 30 minutes) 2 hours after admission (p < 0.05). The VTE patients exhibited delayed coagulation recovery (a significant change compared with 2 hours) of K-value (48 vs 24 hours), α-angle (no recovery), maximum amplitude (24 vs 12 hours), and clot lysis at 30 minutes (48 vs 12 hours). Platelet function recovery mediated by arachidonic acid (72 vs 4 hours), ADP (72 vs 12 hours), and collagen (48 vs 12 hours) was delayed in VTE patients. The VTE patients had lower mortality (4% vs 13%; p < 0.05), but fewer hospital-free days (0 days [interquartile range 0 to 8 days] vs 10 days [interquartile range 0 to 20 days]; p < 0.05) and higher complication rates (p < 0.05). Recovery from platelet dysfunction and coagulopathy after severe trauma were delayed in VTE patients. Suppressed clot lysis and compensatory mechanisms associated with altered coagulation that can potentiate VTE formation require additional investigation. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of the suitability of a plant virus, pepper mild mottle virus, as a surrogate of human enteric viruses for assessment of the efficacy of coagulation-rapid sand filtration to remove those viruses.

    PubMed

    Shirasaki, N; Matsushita, T; Matsui, Y; Yamashita, R

    2018-02-01

    Here, we evaluated the removal of three representative human enteric viruses - adenovirus (AdV) type 40, coxsackievirus (CV) B5, and hepatitis A virus (HAV) IB - and one surrogate of human caliciviruses - murine norovirus (MNV) type 1 - by coagulation-rapid sand filtration, using water samples from eight water sources for drinking water treatment plants in Japan. The removal ratios of a plant virus (pepper mild mottle virus; PMMoV) and two bacteriophages (MS2 and φX174) were compared with the removal ratios of human enteric viruses to assess the suitability of PMMoV, MS2, and φX174 as surrogates for human enteric viruses. The removal ratios of AdV, CV, HAV, and MNV, evaluated via the real-time polymerase chain reaction (PCR) method, were 0.8-2.5-log 10 when commercially available polyaluminum chloride (PACl, basicity 1.5) and virgin silica sand were used as the coagulant and filter medium, respectively. The type of coagulant affected the virus removal efficiency, but the age of silica sand used in the rapid sand filtration did not. Coagulation-rapid sand filtration with non-sulfated, high-basicity PACls (basicity 2.1 or 2.5) removed viruses more efficiently than the other aluminum-based coagulants. The removal ratios of MS2 were sometimes higher than those of the three human enteric viruses and MNV, whereas the removal ratios of φX174 tended to be smaller than those of the three human enteric viruses and MNV. In contrast, the removal ratios of PMMoV were similar to and strongly correlated with those of the three human enteric viruses and MNV. Thus, PMMoV appears to be a suitable surrogate for human enteric viruses for the assessment of the efficacy of coagulation-rapid sand filtration to remove viruses. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The first report on coagulation and phospholipase A2 activities of Persian Gulf lionfish, Pterois russelli, an Iranian venomous fish.

    PubMed

    Memar, Bahareh; Jamili, Shahla; Shahbazzadeh, Delavar; Bagheri, Kamran Pooshang

    2016-04-01

    Pterois russelli is a venomous fish belonging to scorpionidae family. Regarding to high significance value for tracing potential therapeutic molecules and special agents from venomous marine creatures, the present study was aimed to characterization of the Persian Gulf lionfish venom. Proteolytic, phospholipase, hemolytic, coagulation, edematogenic and dermonecrotic activities were determined for extracted venom. The LD50 of P. russelli venom was determined by intravenous injection in white Balb/c mice. Phospholipase A2 activity was recorded at 20 μg of total venom. Coagulation activity on human plasma was shown by Prothrombin Time (PT) and activated Partial Thromboplastin Time (APTT) assays and coagulation visualized after 7 and 14 s respectively for 60 μg of crude venom. LD50 was calculated as 10.5 mg/kg. SDS-PAGE revealed the presence of major and minor protein bands between 6 and 205 kDa. Different amounts of crude venom ranged from 1.87 to 30 μg showed proteolytic activity on casein. The highest edematic activity was detected at 20 μg. Our findings showed that the edematic activity was dose dependent and persisted for 48 h after injection. The crude venom did not induce dermonecrotic activity on rabbit skin and showed no hemolytic activity on human, mouse and rabbit erythrocytes. This is the first report for phospholipase A2 and coagulation activity in venomous fish and venomous marine animals respectively. Proteolytic activity of P. russelli venom is in accordance with the other genara of scorpionidae family. According to venom activity on intrinsic and extrinsic coagulation pathways, lionfish venom would be contained an interesting pharmaceutical agent. This study is pending to further characterization of phospholipase A2, coagulation, and protease activities and also in vivo activity on animal model of surface and internal bleeding. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Radiofrequency thermal ablation in canine femur: evaluation of coagulation necrosis reproducibility and MRI-histopathologic correlation.

    PubMed

    Lee, Jeong Min; Choi, Seong Hong; Park, Hee Seon; Lee, Min Woo; Han, Chang Jin; Choi, Joon-il; Choi, Ja-Young; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    2005-09-01

    Our purposes were to determine whether a single application of radiofrequency energy to normal bone can create coagulation necrosis reproducibly and to assess the accuracy of MRI at revealing the extent of radiofrequency-induced thermal bone injury. Using a 200-W generator and a 17-gauge cooled-tip electrode, a total of 11 radiofrequency ablations were performed under fluoroscopic guidance in the distal femurs of seven dogs. Radiofrequency was applied in standard monopolar mode at 100 W for 10 min. During radiofrequency ablation, the changes in impedance and currents were recorded. MRI, including unenhanced T1- and T2-weighted images and contrast-enhanced fat-suppressed T1-weighted images, was performed to evaluate ablation regions. Six dogs were killed on day 4 after MRI and one dog on day 7. In all animals, radiofrequency ablation created a well-defined coagulation necrosis and no significant complications were noted. The mean long-axis diameter and the mean short-axis diameter of the coagulation zones produced were 45.9 +/- 5.5 mm and 17.7 +/- 2.7 mm, respectively. At gross examination, thermal ablation regions appeared as a central, light-brown area with a dark-brown peripheral hemorrhagic zone, which was surrounded by a pale-yellow rim. On MRI, the ablated areas showed multilayered zones with signal intensities that differed from normal marrow on unenhanced images and a perfusion defect on contrast-enhanced T1-weighted images. The maximum difference between lesion sizes on MR images, established by measuring macroscopic coagulation necrosis, was 3 mm. The correlation between the diameter of coagulation necrosis and lesion size at MRI was strong, with correlation coefficients ranging from 0.89 for unenhanced T1-weighted images and 0.97 for unenhanced T2-weighted images to 0.98 for contrast-enhanced T1-weighted images (p < 0.05). Radiofrequency ablation created well-defined coagulation necrosis in a reproducible manner, and MRI accurately determined the extent of the radiofrequency-induced thermal bone injury.

  2. [Removal of DON in micro-polluted raw water by coagulation and adsorption using activated carbon].

    PubMed

    Liu, Bing; Yu, Guo-Zhong; Gu, Li; Zhao, Cheng-Mei; Li, Qing-Fei; Zhai, Hui-Min

    2013-04-01

    Dissolved organic nitrogen as a precursor of new type nitrogenous disinfection by-products in drinking water attracted gradually the attention of scholars all over the world. In order to explore the mechanism of DON removal in micro-polluted raw water by coagulation and adsorption, water quality parameters, such as DON, DOC, NH4(+) -N, UV254, pH and dissolved oxygen, were determined in raw water and the molecular weight distribution of the DON and DOC was investigated. The variations in DON, DOC and UV254 in the coagulation and adsorption tests were investigated, and the changes of DON in raw water were characterized using three-dimensional fluorescence spectroscopy. The results showed that DON, DOC and UV254 were 1.28 mg x L(-1), 8.56 mg x L(-1), 0.16 cm(-1), and DOC/DON and SUVA were 6.69 mg x mg(-1), 1.87 m(-1) x (mg x L(-1))(-1) in raw water, respectively. The molecular weight distribution of the DON in raw water showed a bimodal distribution. The small molecular weight (< 6 000) fractions accounted for a high proportion of 68% and the large (> 20 000) fractions accounted for about 22%. The removal of DON, DOC and UV254 was about 20%, 26% and 70%, respectively, in the coagulation test and the dosage of coagulant was 10 mg x L(-1). The removal of DON, DOC and UV254 was about 60%, 35% and 100%, respectively, in the adsorption test and the dosage of activated carbon was 1.0 g. In the combination of coagulation and adsorption, the removal of DON and DOC reached approximately 82% and 64%, respectively. 3DEEM revealed that the variation of DON in the coagulation and adsorption tests depended intimately on tryptophan protein-like substances, aromatic protein-like substances and fulvic acid-like substances.

  3. [Comparison of shaft temperature related treatment efficacy between "air-cooled" microwave coagulation and traditional microwave coagulation].

    PubMed

    Zheng, Yun; Li, Jin-Qing; Chen, Min-Shan; Zhang, Yao-Jun; Zhang, Ya-Qi

    2004-11-01

    The application and development of traditional percutaneous microwave coagulation therapy (PMCT) has been limited by high shaft temperature. The "air-cooled" PMCT is the newest advancement. This study was to compare shaft temperature related treatment efficacy between "air-cooled" PMCT and traditional PMCT. Two pigs underwent traditional PMCT, and "air-cooled" PMCT at 80 W for 10 min separately. Skin injury, surface temperature of guide-needle, charring tissue sticking to the shaft, and lesion shape in 2 pigs were compared. Five patients with liver tumor received traditional PMCT, and 8 patients with liver tumor received "air-cooled" PMCT. Feeling of pain, skin injury, charring tissue sticking to the shaft, local therapeutic efficacy, and recurrence of these 2 groups of patients were compared. In the pig underwent traditional PMCT, surface temperature of guide-needle reached 119-160 Centigrade; skin burn around puncture points was serious; charring tissue stuck to the front of electrodes; a trail sign was observed in coagulated lesion. In the pig underwent "air-cooled" PMCT, surface temperature of guide-needle was 28.8-39.9 Centigrade; no skin injury was found around puncture points; no charring tissue stuck to the front of electrodes; no obvious trail sign was observed in coagulated lesion. In 5 patients received traditional PMCT, 3 had skin injury; 2 had charring tissue stuck to the front of electrode; all felt moderate or serious epigastric pain lasted for 1-8 weeks; 4 had complete coagulation; 1 had local recurrence. In 8 patients received "air-cooled" PMCT, no one had skin injury, and charring tissue stuck to "air-cooled" electrode; 4 felt slight epigastric pain within 1 week; all had complete coagulation; no local recurrence was found. The technique of "air-cooled" electrode may decrease temperature of shaft safely and reliably, and eliminate side effects arose from high temperature of shaft. Treatment efficacy of "air-cooled" PMCT is better than that of traditional PMCT.

  4. Using Chitosan/CHPATC as coagulant to remove color and turbidity of industrial wastewater: Optimization through RSM design.

    PubMed

    Momeni, Meysam Mohammad; Kahforoushan, Davood; Abbasi, Farhang; Ghanbarian, Saeid

    2018-04-01

    One of the most important solid-liquid separation processes is coagulation and flocculation that is extensively used in the primary treatment of industrial wastewater. The biopolymers, because of biodegradable properties and low cost have been used as coagulants. In this study, chitosan as a natural coagulant of choice, was modified by (3-chloro 2-hydroxypropyl)trimethylammonium chloride and was used to remove the color and turbidity of industrial wastewater. To evaluate the effect of pH, settling time, the initial turbidity of wastewater, the amount of coagulant, and the concentration of dye (Melanoidin) were chosen to study their effects on removal of wastewater color and turbidity. The experiments were done in a batch system by using a jar test. To achieve the optimum conditions for the removal of color and turbidity, the response surface methodology (RSM) experimental design method was used. The results obtained from experiments showed that the optimum conditions for the removal of color were as: pH = 3, concentration of dye = 1000 mg/L, settling time = 78.93 min, and dose of coagulant = 3 g/L. The maximum color removal in these conditions was predicted 82.78% by the RSM model. The optimal conditions for the removal of turbidity of the waste water were as: pH = 5.66, initial turbidity = 60 NTU, settling time = 105 min, and amount of coagulant = 3 g/L. The maximum turbidity removal in these circumstances was predicted 94.19% by the model. The experimental results obtained in optimum conditions for removal of color and turbidity were 76.20% and 90.14%, respectively, indicating the high accuracy of the prediction model. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. 21 CFR 172.824 - Sodium mono- and dimethyl naphthalene sulfonates.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intended for use in potable water systems to reduce hardness and aid in sedimentation and coagulation by raising the pH for the efficient utilization of other coagulation materials. (2) As an anticaking agent in...

  6. 21 CFR 172.824 - Sodium mono- and dimethyl naphthalene sulfonates.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intended for use in potable water systems to reduce hardness and aid in sedimentation and coagulation by raising the pH for the efficient utilization of other coagulation materials. (2) As an anticaking agent in...

  7. The Intrinsic Pathway of Coagulation as a Target for Antithrombotic Therapy

    PubMed Central

    Wheeler, Allison P.; Gailani, David

    2016-01-01

    Plasma coagulation in the activated partial thromboplastin time assay is initiated by sequential activation of coagulation factors XII, XI and IX – the classical intrinsic pathway of coagulation. It is well recognized that this series of proteolytic reactions is not an accurate model for hemostasis in vivo, as factor XII deficiency does not cause abnormal bleeding, and fXI deficiency causes a relatively mild propensity to bleed excessively with injury. Despite their limited roles in hemostasis, there is mounting evidence that fXI and fXII contribute to thrombosis, and that inhibiting them can produce an antithrombotic effect with a relatively small effect on hemostasis. In this chapter the contributions of components of the intrinsic pathway to thrombosis in animal models and humans are discussed, and results of early clinical trials of drugs targeting factors IX, XI and XII are presented. PMID:27637310

  8. Effects of Acute Stress on Thrombosis.

    PubMed

    Bentur, Ohad S; Sarig, Galit; Brenner, Benjamin; Jacob, Giris

    2018-06-18

    Stress, the nonspecific response to any demand for change, is an adaptive response of the human body to various stimulants. As such, stress-induced hypercoagulation may represent an adaptive response to bleeding. Numerous epidemiological studies have revealed that a correlation exists between stress and thrombotic risk and biochemically, links of the relationship between psychological stress and coagulation pathways have been made. The stress reaction is coupled with neurohormonal changes mediated mainly by the sympathetic neural system and the hypothalamic-pituitary-adrenal axis. Singling out the specific pathways affecting coagulation in this complex response is hampered by many confounders. The mediators of the stress reaction (neurotransmitters and hormones) can directly affect platelets and the coagulation cascade and indirectly affect hemostasis via changes in hemodynamics. In this review, the authors will delineate the distinct neurobiological mechanisms that govern the effects of stress on coagulation, and report their recent findings. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. A review on palm oil mill biogas plant wastewater treatment using coagulation-ozonation

    NASA Astrophysics Data System (ADS)

    Dexter, Z. D.; Joseph, C. G.; Zahrim, A. Y.

    2016-06-01

    Palm oil mill effluent (POME) generated from the palm oil industry is highly polluted and requires urgent attention for treatment due to its high organic content. Biogas plant containing anaerobic digester is capable to treat the high organic content of the POME while generating valuable biogas at the same time. This green energy from POME is environmental-friendly but the wastewater produced is still highly polluted and blackish in colour. Therefore a novel concept of combining coagulation with ozonation treatment is proposed to treat pollution of this nature. Several parameters should be taken under consideration in order to ensure the effectiveness of the hybrid treatment including ozone dosage, ozone contact time, pH of the water or wastewater, coagulant dosage, and mixing and settling time. This review paper will elucidate the importance of hybrid coagulation-ozonation treatment in producing a clear treated wastewater which is known as the main challenge in palm oil industry

  10. Coagulation Abnormalities of Sickle Cell Disease: Relationship with Clinical Outcomes and the Effect of Disease Modifying Therapies

    PubMed Central

    Noubouossie, Denis; Key, Nigel S.; Ataga, Kenneth I.

    2015-01-01

    Sickle cell disease (SCD) is a hypercoagulable state. Patients exhibit increased platelet activation, high plasma levels of markers of thrombin generation, depletion of natural anticoagulant proteins, abnormal activation of the fibrinolytic system, and increased tissue factor expression, even in the non-crisis “steady state.” Furthermore, SCD is characterized by an increased risk of thrombotic complications. The pathogenesis of coagulation activation in SCD appears to be multi-factorial, with contributions from ischemia-reperfusion injury and inflammation, hemolysis and nitric oxide deficiency, and increased sickle RBC phosphatidylserine expression. Recent studies in animal models suggest that activation of coagulation may contribute to the pathogenesis of SCD, but the data on the contribution of coagulation and platelet activation to SCD-related complications in humans are limited. Clinical trials of new generations of anticoagulants and antiplatelet agents, using a variety of clinical endpoints are warranted. PMID:26776344

  11. Structural characterization of coagulant Moringa oleifera Lectin and its effect on hemostatic parameters.

    PubMed

    Luz, Luciana de Andrade; Silva, Mariana Cristina Cabral; Ferreira, Rodrigo da Silva; Santana, Lucimeire Aparecida; Silva-Lucca, Rosemeire Aparecida; Mentele, Reinhard; Oliva, Maria Luiza Vilela; Paiva, Patricia Maria Guedes; Coelho, Luana Cassandra Breitenbach Barroso

    2013-07-01

    Lectins are carbohydrate recognition proteins. cMoL, a coagulant Moringa oleifera Lectin, was isolated from seeds of the plant. Structural studies revealed a heat-stable and pH resistant protein with 101 amino acids, 11.67 theoretical pI and 81% similarity with a M. oleifera flocculent protein. Secondary structure content was estimated as 46% α-helix, 12% β-sheets, 17% β-turns and 25% unordered structures belonging to the α/β tertiary structure class. cMoL significantly prolonged the time required for blood coagulation, activated partial thromboplastin (aPTT) and prothrombin times (PT), but was not so effective in prolonging aPTT in asialofetuin presence. cMoL acted as an anticoagulant protein on in vitro blood coagulation parameters and at least on aPTT, the lectin interacted through the carbohydrate recognition domain. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Radio-frequency lesioning in brain tissue with coagulation-dependent thermal conductivity: modelling, simulation and analysis of parameter influence and interaction.

    PubMed

    Johansson, Johannes D; Eriksson, Ola; Wren, Joakim; Loyd, Dan; Wårdell, Karin

    2006-09-01

    Radio-frequency brain lesioning is a method for reducing e.g. symptoms of movement disorders. A small electrode is used to thermally coagulate malfunctioning tissue. Influence on lesion size from thermal and electric conductivity of the tissue, microvascular perfusion and preset electrode temperature was investigated using a finite-element model. Perfusion was modelled as an increased thermal conductivity in non-coagulated tissue. The parameters were analysed using a 2(4)-factorial design (n=16) and quadratic regression analysis (n=47). Increased thermal conductivity of the tissue increased lesion volume, while increased perfusion decreased it since coagulation creates a thermally insulating layer due to the cessation of blood perfusion. These effects were strengthened with increased preset temperature. The electric conductivity had negligible effect. Simulations were found realistic compared to in vivo experimental lesions.

  13. The use of Moringa Oleifera Seed Powder as Coagulant to Improve the Quality of Wastewater and Ground Water

    NASA Astrophysics Data System (ADS)

    Hendrawati; Rani Yuliastri, Indra; Nurhasni; Rohaeti, Eti; Effendi, Hefni; Darusman, Latifah K.

    2016-01-01

    Wastewater and ground water treatment are mostly using Polyaluminum Chloride (PAC), a synthetic coagulant, which possess health risk and require expensive cost. This research was carried out to observe the effect of Moringa oleifera seed as natural coagulant to replace synthetic coagulant. M. oleifera reduced 98.6% turbidity of wastewater, 10.8% of its conductivity, 11.7% of its BOD and removed its metal contents (Cd, Cr, Mn). When applied to ground water, M. oleifera removed the turbidity of ground water as much as 97.5%, while reduced the conductivity and BOD of ground water 53.4% and 18%, respectively. The use of M. oleifera also reduced total number of coliform. The advantage of using M. oleifera is that it does not reduce pH as PAC, hence does not require further treatment to adjust pH of the treated water.

  14. Enzymatic lipid oxidation by eosinophils propagates coagulation, hemostasis, and thrombotic disease

    PubMed Central

    Uderhardt, Stefan; Ackermann, Jochen A.; Fillep, Tobias; Hammond, Victoria J.; Willeit, Johann; Stark, Konstantin; Rossaint, Jan; Schubert, Irene; Mielenz, Dirk; Dietel, Barbara; Raaz-Schrauder, Dorette; Ay, Cihan; Thaler, Johannes; Heim, Christian; Collins, Peter W.; Schabbauer, Gernot; Mackman, Nigel; Voehringer, David; Nadler, Jerry L.; Lee, James J.; Massberg, Steffen; Rauh, Manfred; O’Donnell, Valerie B.

    2017-01-01

    Blood coagulation is essential for physiological hemostasis but simultaneously contributes to thrombotic disease. However, molecular and cellular events controlling initiation and propagation of coagulation are still incompletely understood. In this study, we demonstrate an unexpected role of eosinophils during plasmatic coagulation, hemostasis, and thrombosis. Using a large-scale epidemiological approach, we identified eosinophil cationic protein as an independent and predictive risk factor for thrombotic events in humans. Concurrent experiments showed that eosinophils contributed to intravascular thrombosis by exhibiting a strong endogenous thrombin-generation capacity that relied on the enzymatic generation and active provision of a procoagulant phospholipid surface enriched in 12/15-lipoxygenase–derived hydroxyeicosatetraenoic acid–phosphatidylethanolamines. Our findings reveal a previously unrecognized role of eosinophils and enzymatic lipid oxidation as regulatory elements that facilitate both hemostasis and thrombosis in response to vascular injury, thus identifying promising new targets for the treatment of thrombotic disease. PMID:28566277

  15. Integrated process for the removal of emulsified oils from effluents in the steel industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benito, J.M.; Rios, G.; Gutierrez, B.

    1999-11-01

    Emulsified oils contained in aqueous effluents from cold-rolling mills of the steel industry can be effectively removed via an integrated process consisting of a coagulation/flocculation stage followed by ultrafiltration of the resulting aqueous phase. The effects of CaCl{sub 2}, NaOH, and lime on the stability of different industrial effluents were studied in the coagulation experiments. The flocculants tested were inorganic prehydrolyzed aluminum salts and quaternary polyamines. Ultrafiltration of the aqueous phase from the coagulation/flocculation stage was carried out in a stirred cell using Amicon PM30 and XM300 organic membranes. Permeate fluxes were measured for industrial effluents to which the indicatedmore » coagulants and flocculants had been added. Oil concentrations in the permeate were 75% lower than the limits established by all European Union countries. Complete regeneration of the membrane was accomplished with an aqueous solution of a commercial detergent.« less

  16. Effect of a continuous regimen of contraceptive combination of ethinylestradiol and drospirenone on lipid, carbohydrate and coagulation profiles.

    PubMed

    Machado, Rogério Bonassi; de Melo, Nilson Roberto; Maia, Hugo; Cruz, Achilles Machado

    2010-02-01

    The objective of this study was to evaluate the effects of a contraceptive pill containing ethinylestradiol (30 mcg) and drospirenone (3 mg) in a continuous regimen on lipid, carbohydrate and coagulation parameters. This open, prospective, randomized study included 78 participants (mean age 27.8 years) who were randomized into two groups to use the pill continuously for 168 days or for six 28-day cycles with a 7-day hormone-free interval between cycles. Markers of lipid, carbohydrate and coagulation profiles were measured prior to initiation and after the 6 months of pill use. No statistically significant differences were found between the two contraceptive regimens with respect to carbohydrate or lipid profiles or in the parameters related to coagulation. The contraceptive combination of ethinylestradiol and drospirenone used in a continuous regimen was associated with metabolic alterations similar to those found during the traditional cyclic regimen of oral contraceptive use.

  17. Characterization and removal of natural organic matter from slow sand filter effluent followed by alum coagulation

    NASA Astrophysics Data System (ADS)

    Hidayah, Euis Nurul; Chou, Yung-Chen; Yeh, Hsuan-Hsien

    2018-03-01

    Characterization and removal of natural organic matter, which is contained in the effluent of slow sand filters, was observed by alum coagulation under various dosages. In addition to non-purgedable dissolved organic carbon (NPDOC), trihalomethanes formation potential (THMFP) and haloacetic acid formation potential (HAAFP) measurement, high-performance size-exclusion chromatography (HPSEC) with ultraviolet/visible and dissolved organic carbon (DOC) detectors was used to characterize the various organic fractions contained in the water before and after coagulation. The results show that alum coagulation could effectively remove hydrophobic aromatic, which forms mainly humic substances. The reduction in THMFP was found to be higher than that of NPDOC and HAAFP under specific alum dosage, and the former was also found to be proportional to the corresponding reduction in the area of hydrophobic aromatic fraction, mostly humic subtances, as obtained from HPSEC chromatogram with peak-fitting.

  18. Role of plasma kallikrein in diabetes and metabolism.

    PubMed

    Feener, E P; Zhou, Q; Fickweiler, W

    2013-09-01

    Plasma kallikrein (PK) is a serine protease generated from plasma prekallikrein, an abundant circulating zymogen expressed by the Klkb1 gene. The physiological actions of PK have been primarily attributed to its production of bradykinin and activation of coagulation factor XII, which promotes inflammation and the intrinsic coagulation pathway. Recent genetic, molecular, and pharmacological studies of PK have provided further insight into its role in physiology and disease. Genetic analyses have revealed common Klkb1 variants that are association with blood metabolite levels, hypertension, and coagulation. Characterisation of animal models with Klkb1 deficiency and PK inhibition have demonstrated effects on inflammation, vascular function, blood pressure regulation, thrombosis, haemostasis, and metabolism. These reports have also identified a host of PK substrates and interactions, which suggest an expanded physiological role for this protease beyond the bradykinin system and coagulation. The review summarises the mechanisms that contribute to PK activation and its emerging role in diabetes and metabolism.

  19. The effect of exercise on coagulation and fibrinolysis factors in patients with peripheral arterial disease.

    PubMed

    Patelis, Nikolaos; Karaolanis, Georgios; Kouvelos, Georgios N; Hart, Collin; Metheiken, Sean

    2016-09-01

    Peripheral arterial disease is a widely prevalent atherosclerotic occlusive disorder. Symptoms commence with exercise-induced pain in the lower extremities, known as claudication. Despite the fact that exercise has been shown to improve fibrinolytic profile some patients, the effect of exercise on coagulation and fibrinolysis cascades in claudicants has not been comprehensively defined. Literature search in English language yielded 13 studies of exercise on claudicants, including 420 patients. Claudicants tend to have a higher coagulation activity at rest compared to healthy individuals, a trend that persists even after exercise. Post-exercise coagulation activity of claudicants is increased when compared to their respective baseline levels, but it is so in a non-consistent manner. From the available data, it has been suggested that claudicants have a functional and effective fibrinolytic mechanism in place, operating continuously at a relatively higher activity level compared to healthy individuals. Fibrinolysis seems to be activated by exercise; a positive outcome with a prolonged effect as shown by a few of the studies. A final conclusion whether coagulation or fibrinolysis activity is affected mostly by exercise type and intensity in claudicants could not be answered. All conclusions regarding the effect of exercise on the coagulation and fibrinolysis mechanisms should be taken under cautious consideration, due to the limited number of studies, the small number of patients and the different exercise strategies employed in each study. Further randomized studies with similar exercise protocols could provide safer conclusions in the future. © 2016 by the Society for Experimental Biology and Medicine.

  20. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing: Interactions among coagulant and flocculant concentrations and pH value.

    PubMed

    Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R

    2009-11-01

    Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.

  1. Coagulation phenotypes in septic shock as evaluated by calibrated automated thrombography.

    PubMed

    Perrin, Julien; Charron, Cyril; François, Jean-Hugues; Cramer-Bordé, Elisabeth; Lévy, Bruno; Borgel, Delphine; Vieillard-Baron, Antoine

    2015-01-01

    Sepsis induces alterations of coagulation suggesting both hypercoagulable or hypocoagulable features. The result of their combination remains unknown, making it difficult to predict whether one prevails over the other. Thrombin generation tests (TGTs) stand as an interesting tool to establish an integrative phenotype of coagulation. It has been reported that septic patients display a hypocoagulable trait using TGT. However, protein C (PC) system response was not evaluated. We aimed at describing the thrombin generation profile in patients with septic shock under conditions that are sensitive to PC system to evaluate the net results of coagulation abnormalities and to determine whether hypercoagulable or hypocoagulable traits coexist within a given individual. Thrombin generation was studied in plasma from patients presenting with septic shock at diagnosis and 6 h after a conventional therapeutic management using calibrated automated thrombography with or without thrombomodulin (TM) addition. Patients exhibit clear alterations of TGT that present as both consumption-related hypocoagulability (evidenced without TM addition) but also hypercoagulability by decreased sensitivity to the PC system evidenced with TM addition. No difference could be demonstrated between survivors and nonsurvivors at Day 28, but patients who do not respond to therapeutics at 6 h seem to be more hypercoagulable. More importantly, if our results evidence heterogeneity between patients, we show that alterations of coagulation result in an equilibrium in the majority of patients, thus suggesting "normocoagulability"; but, in the presence of a biological imbalance between baseline thrombin generation and sensitivity to TM, the global effect mostly tends toward hypercoagulability. Thus, TGT may help identify distinct biological coagulation phenotypes in the complex alterations induced by sepsis.

  2. Biomaterials trigger endothelial cell activation when co-incubated with human whole blood.

    PubMed

    Herklotz, Manuela; Hanke, Jasmin; Hänsel, Stefanie; Drichel, Juliane; Marx, Monique; Maitz, Manfred F; Werner, Carsten

    2016-10-01

    Endothelial cell activation resulting from biomaterial contact or biomaterial-induced blood activation may in turn also affect hemostasis and inflammatory processes in the blood. Current in vitro hemocompatibility assays typically ignore these modulating effects of the endothelium. This study describes a co-incubation system of human whole blood, biomaterial and endothelial cells (ECs) that was developed to overcome this limitation. First, human endothelial cells were characterized in terms of their expression of coagulation- and inflammation-relevant markers in response to various activators. Subsequently, their capacity to regulate hemostasis as well as complement and granulocyte activation was monitored in a hemocompatibility assay. After blood contact, quiescent ECs exhibited anticoagulant and anti-inflammatory properties. When they were co-incubated with surfaces exhibiting pro-coagulant or pro-inflammatory characteristics, the ECs down-regulated coagulation but not complement or leukocyte activation. Analysis of intracellular levels of the endothelial activation markers E-selectin and tissue factor showed that co-incubation with model surfaces and blood significantly increased the activation state of ECs. Finally, the coagulation- and inflammation-modulating properties of the ECs were tested after blood/biomaterial exposure. Pre-activation of ECs by biomaterials in the blood induced a pro-coagulant and pro-inflammatory state of the ECs, wherein the pro-coagulant response was higher for biomaterial/blood pre-activated ECs than for TNF-α-pre-activated cells. This work provides evidence that biomaterials, even without directly contacting the endothelium, affect the endothelial activation state with and have consequences for plasmatic and cellular reactions in the blood. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Simultaneous removal of ammonia and N-nitrosamine precursors from high ammonia water by zeolite and powdered activated carbon.

    PubMed

    Xue, Runmiao; Donovan, Ariel; Zhang, Haiting; Ma, Yinfa; Adams, Craig; Yang, John; Hua, Bin; Inniss, Enos; Eichholz, Todd; Shi, Honglan

    2018-02-01

    When adding sufficient chlorine to achieve breakpoint chlorination to source water containing high concentration of ammonia during drinking water treatment, high concentrations of disinfection by-products (DBPs) may form. If N-nitrosamine precursors are present, highly toxic N-nitrosamines, primarily N-nitrosodimethylamine (NDMA), may also form. Removing their precursors before disinfection should be a more effective way to minimize these DBPs formation. In this study, zeolites and activated carbon were examined for ammonia and N-nitrosamine precursor removal when incorporated into drinking water treatment processes. The test results indicate that Mordenite zeolite can remove ammonia and five of seven N-nitrosamine precursors efficiently by single step adsorption test. The practical applicability was evaluated by simulation of typical drinking water treatment processes using six-gang stirring system. The Mordenite zeolite was applied at the steps of lime softening, alum coagulation, and alum coagulation with powdered activated carbon (PAC) sorption. While the lime softening process resulted in poor zeolite performance, alum coagulation did not impact ammonia and N-nitrosamine precursor removal. During alum coagulation, more than 67% ammonia and 70%-100% N-nitrosamine precursors were removed by Mordenite zeolite (except 3-(dimethylaminomethyl)indole (DMAI) and 4-dimethylaminoantipyrine (DMAP)). PAC effectively removed DMAI and DMAP when added during alum coagulation. A combination of the zeolite and PAC selected efficiently removed ammonia and all tested seven N-nitrosamine precursors (dimethylamine (DMA), ethylmethylamine (EMA), diethylamine (DEA), dipropylamine (DPA), trimethylamine (TMA), DMAP, and DMAI) during the alum coagulation process. Copyright © 2017. Published by Elsevier B.V.

  4. Blood coagulation screening using a paper-based microfluidic lateral flow device.

    PubMed

    Li, H; Han, D; Pauletti, G M; Steckl, A J

    2014-10-21

    A simple approach to the evaluation of blood coagulation using a microfluidic paper-based lateral flow assay (LFA) device for point-of-care (POC) and self-monitoring screening is reported. The device utilizes whole blood, without the need for prior separation of plasma from red blood cells (RBC). Experiments were performed using animal (rabbit) blood treated with trisodium citrate to prevent coagulation. CaCl2 solutions of varying concentrations are added to citrated blood, producing Ca(2+) ions to re-establish the coagulation cascade and mimic different blood coagulation abilities in vitro. Blood samples are dispensed into a paper-based LFA device consisting of sample pad, analytical membrane and wicking pad. The porous nature of the cellulose membrane separates the aqueous plasma component from the large blood cells. Since the viscosity of blood changes with its coagulation ability, the distance RBCs travel in the membrane in a given time can be related to the blood clotting time. The distance of the RBC front is found to decrease linearly with increasing CaCl2 concentration, with a travel rate decreasing from 3.25 mm min(-1) for no added CaCl2 to 2.2 mm min(-1) for 500 mM solution. Compared to conventional plasma clotting analyzers, the LFA device is much simpler and it provides a significantly larger linear range of measurement. Using the red colour of RBCs as a visible marker, this approach can be utilized to produce a simple and clear indicator of whether the blood condition is within the appropriate range for the patient's condition.

  5. Could light meal jeopardize laboratory coagulation tests?

    PubMed

    Lima-Oliveira, Gabriel; Salvagno, Gian Luca; Lippi, Giuseppe; Danese, Elisa; Gelati, Matteo; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2014-01-01

    Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests. A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV). A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104-117) and 111 (107-120) vs. 109 (102-118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9-34.8) vs. 34.1 (32.2-35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV. A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.

  6. Equiosmolar Solutions of Hypertonic Saline and Mannitol Do Not Impair Blood Coagulation During Elective Intracranial Surgery.

    PubMed

    Hernández-Palazón, Joaquín; Fuentes-García, Diego; Doménech-Asensi, Paloma; Piqueras-Pérez, Claudio; Falcón-Araña, Luis; Burguillos-López, Sebastián

    2017-01-01

    The authors investigated the effect of equiosmolar, equivolemic solutions of 3% hypertonic saline (HS) and 20% mannitol on blood coagulation assessed by rotational thromboelastometry (ROTEM) and standard coagulation tests during elective craniotomy. In a prospective, randomized, double-blind trial, 40 patients undergoing elective craniotomy were randomized to receive 5 mL/kg of either 20% mannitol or 3% HS for intraoperative brain relaxation. Fibrinogen, activated partial thromboplastin time, prothrombin time, hemoglobin, hematocrit, and platelet count were simultaneously measured intraoperatively with ROTEM for EXTEM, INTEM, and FIBTEM analysis. ROTEM parameters were: clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), and α-angle. No significant differences between groups were found in ROTEM variables CT, CFT, MCF, α-angle (EXTEM and INTEM), and MCF (FIBTEM) nor standard coagulation tests. ROTEM parameters did not show changes after administration of hyperosmolar solutions relating to basal values, except for an increase of CFT EXTEM (118±28 vs. 128±26 s) and decrease of CT INTEM (160±18 vs. 148±15 s) with values within normal range. Significant decreases from baseline levels were observed for hematocrit (-7%), platelet count (-10%), and fibrinogen (-13%) after HS infusion, and hematocrit (-9%), platelet count (-13%), and fibrinogen (-9%) after mannitol infusion, but remaining normal. The use of 5 mL/kg of equiosmolar solutions of 3% HS and 20% mannitol applied to reach a brain relaxation during elective craniotomy does not induce coagulation impairment as evidenced by ROTEM and standard coagulation tests.

  7. Spectroscopy of reactive species produced by low-energy atmospheric-pressure plasma on conductive target material surface

    NASA Astrophysics Data System (ADS)

    Yamada, Hiromasa; Sakakita, Hajime; Kato, Susumu; Kim, Jaeho; Kiyama, Satoru; Fujiwara, Masanori; Itagaki, Hirotomo; Okazaki, Toshiya; Ikehara, Sanae; Nakanishi, Hayao; Shimizu, Nobuyuki; Ikehara, Yuzuru

    2016-10-01

    A method for blood coagulation using low-energy atmospheric-pressure plasma (LEAPP) is confirmed as an alternative procedure to reduce tissue damage caused by heat. Blood coagulation using LEAPP behaves differently depending on working gas species; helium is more effective than argon in promoting fast coagulation. To analyse the difference in reactive species produced by helium and argon plasma, spectroscopic measurements were conducted without and with a target material. To compare emissions, blood coagulation experiments using LEAPP for both plasmas were performed under almost identical conditions. Although many kinds of reactive species such as hydroxyl radicals and excited nitrogen molecules were observed with similar intensity in both plasmas, intensities of nitrogen ion molecules and nitric oxide molecules were extremely strong in the helium plasma. It is considered that nitrogen ion molecules were mainly produced by penning ionization by helium metastable. Near the target, a significant increase in the emissions of reactive species is observed. There is a possibility that electron acceleration was induced in a local electric field formed on the surface. However, in argon plasma, emissions from nitrogen ion were not measured even near the target surface. These differences between the two plasmas may be producing the difference in blood coagulation behaviour. To control the surrounding gas of the plasma, a gas-component-controllable chamber was assembled. Filling the chamber with O2/He or N2/He gas mixtures selectively produces either reactive oxygen species or reactive nitrogen species. Through selective treatments, this chamber would be useful in studying the effects of specific reactive species on blood coagulation.

  8. The effect of cooling on coagulation and haemostasis: should "Ice" be part of treatment of acute haemarthrosis in haemophilia?

    PubMed

    Forsyth, A L; Zourikian, N; Valentino, L A; Rivard, G E

    2012-11-01

    Repeated haemarthroses and the consequences of blood in the joint contribute to blood induced joint disease (BIJD) in people with haemophilia (PWH). Prevention of bleeding, through medical management, is the standard of care in developed countries, but is not universally available due to financial and other barriers. Ice application, as part of R.I.C.E. (Rest, Ice, Compression, Elevation) or alone, is commonly recommended as an adjunct treatment to decrease bleeding, pain, tissue metabolism, oedema, and inflammation. This article will review evidence regarding local cooling by commonly used ice application methods, to decrease the temperature of the skin and intra-articular (IA) joint space and the resultant effects on haemostasis and coagulation. The general literature was reviewed for articles in English describing temperatures achievable in the skin and IA space using clinically relevant ice protocols, and the effect of cooling on haemostasis and coagulation. The literature demonstrates that typical methods of ice application can cool both the skin and IA space. Published, general literature studies have also consistently demonstrated that experimental cooling of blood and/or tissue, both in vitro and in vivo in humans and in animal models, can significantly impair coagulation and prolong bleeding. In PWH with acute haemarthrosis, ice application has potential to increase haemorrhage morbidity by further impairing coagulation and haemostasis. Ice has not been shown to improve overall outcome, stop bleeding nor swelling from haemarthrosis. Although ice can help manage acute, haemarthrosis-related pain, there are other available interventions that will not impair coagulation and haemostasis. © 2012 Blackwell Publishing Ltd.

  9. Reduced plasma levels of coagulation factors in relation to prostate cancer.

    PubMed

    Beecken, Wolf-Dietrich; Bentas, Wassilios; Engels, Knut; Glienke, Wolfgang; Urbschat, Anja; Jonas, Dietger; Binder, Jochen; Scharrer, Inge

    2002-10-01

    Prostate cancer has historically been associated with coagulation abnormalities. This study was undertaken to investigate the prevalence of abnormalities of coagulation factors in patients with prostate cancer before and after radical prostatectomy (RP). Because coagulation factors have been shown to be involved in tumor angiogenesis, the vascular density of the prostate tumors was assessed. Plasma of 40 consecutive patients with histologically proven prostate cancer was investigated pre-RP and post-RP. The antigen level for antithrombin, plasminogen activator inhibitor-1, and heparin cofactor-II, and the plasma activity of antithrombin and plasminogen were determined by using immunologic and chromogenic assays. The values of these assays were compared with a group of 28 male, age-matched patients without any evidence of cancer and 18 patients with orthopedic interventions preoperatively and postoperatively. The vascular density of the prostate tumors was assessed by staining paraffin sections with an antibody to CD34. The median plasma antigen levels and/or activities of the investigated factors were below normal in the prostate cancer patients before RP. Furthermore, coagulation factors were significantly lower than in the age-matched control group and patients before and after orthopedic surgery. In prostate cancer patients, the median values of all investigated factors went up to normal levels within 2 weeks after RP, whereas postsurgical levels in orthopedic patients remained stable. No correlations to tumor parameters have been observed. We assume that the reduction of these coagulation factors is a principle concept in prostate cancer that needs further investigation. Copyright 2002 Wiley-Liss, Inc.

  10. Endovascular treatment of chronic cerebro spinal venous insufficiency in patients with multiple sclerosis modifies circulating markers of endothelial dysfunction and coagulation activation: a prospective study.

    PubMed

    Napolitano, Mariasanta; Bruno, Aldo; Mastrangelo, Diego; De Vizia, Marcella; Bernardo, Benedetto; Rosa, Buonagura; De Lucia, Domenico

    2014-10-01

    We performed a monocentric observational prospective study to evaluate coagulation activation and endothelial dysfunction parameters in patients with multiple sclerosis undergoing endovascular treatment for cerebro-spinal-venous insufficiency. Between February 2011 and July 2012, 144 endovascular procedures in 110 patients with multiple sclerosis and chronical cerebro-spinal venous insufficiency were performed and they were prospectively analyzed. Each patient was included in the study according to previously published criteria, assessed by the investigators before enrollment. Endothelial dysfunction and coagulation activation parameters were determined before the procedure and during follow-up at 1, 3, 6, 9, 12, 15 and 18 months after treatment, respectively. After the endovascular procedure, patients were treated with standard therapies, with the addition of mesoglycan. Fifty-five percent of patients experienced a favorable outcome of multiple sclerosis within 1 month after treatment, 25% regressed in the following 3 months, 24.9% did not experience any benefit. In only 0.1% patients, acute recurrence was observed and it was treated with high-dose immunosuppressive therapy. No major complications were observed. Coagulation activation and endothelial dysfunction parameters were shown to be reduced at 1 month and stable up to 12-month follow-up, and they were furthermore associated with a good clinical outcome. Endovascular procedures performed by a qualified staff are well tolerated; they can be associated with other currently adopted treatments. Correlations between inflammation, coagulation activation and neurodegenerative disorders are here supported by the observed variations in plasma levels of markers of coagulation activation and endothelial dysfunction.

  11. Detection of tissue coagulation by decorrelation of ultrasonic echo signals in cavitation-enhanced high-intensity focused ultrasound treatment.

    PubMed

    Yoshizawa, Shin; Matsuura, Keiko; Takagi, Ryo; Yamamoto, Mariko; Umemura, Shin-Ichiro

    2016-01-01

    A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.

  12. Normal Hemostatic Profiles and Coagulation Factors in Healthy Free-Living Florida Manatees ( Trichechus manatus latirostris).

    PubMed

    Barratclough, Ashley; Floyd, Ruth Francis; Conner, Bobbi; Reep, Roger; Ball, Ray; Stacy, Nicole

    2016-10-01

    Hemostatic disorders presumptively play an important role in the pathophysiology of several important disease conditions in the Florida manatee ( Trichechus manatus latirostris). Prior to pursuing such clinical implications, it is essential to establish normal hemostatic profiles in clinically healthy animals. During annual health assessments of free-living manatees organized by the US Geological Survey, blood samples were collected from 12 healthy animals from the Atlantic coast and 28 from the Gulf of Mexico coast of Florida, with body lengths of 210-324 cm. The following analyses were performed on citrated plasma: prothrombin (PT), partial thromboplastin time (PTT), and concentrations of fibrinogen, D-dimers, and coagulation factors VII, VIII, IX, X, XI, and XII. Compared to other mammalian species, manatees had short PT (9.2±1.5 s) and PTT (10.7±0.5 s), fibrinogen was 369±78.7 mg/dL, antithrombin III was 132±11%, and D-dimer was 142±122 ng/mL. Baseline concentrations for the listed coagulation factors were established. When comparing coagulation factors between locations, Atlantic coast manatees had significantly higher factors VIII, IX, and X than did Gulf Coast manatees. This finding may reflect differences in water salinity, diet, or genetics. There were no differences in coagulation factors when among sexes and sizes. These baselines for hemostatic profiles and coagulation factors in healthy free-living manatees lay the foundation for diagnosis and future research of hemostatic disorders and contribute to understanding their role in the pathophysiology of manatees affected by various diseases.

  13. CRYPTOSPORIDIUM INACTIVATION AND REMOVAL RESEARCH

    EPA Science Inventory

    Bench- and pilot-scale tests were performed to assess the ability of conventional treatment, ozonation and chlorine dioxide to remove and inactivate Cryptosporidium oocysts. The impacts of coagulant type, coagulant dose, raw water quality, filter loading rates and filter media w...

  14. 21 CFR 172.824 - Sodium mono- and dimethyl naphthalene sulfonates.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... systems to reduce hardness and aid in sedimentation and coagulation by raising the pH for the efficient utilization of other coagulation materials. (2) As an anticaking agent in sodium nitrite at a level not in...

  15. CARDIOVASCULAR AND BLOOD COAGULATION EFFECTS OF PULMONARY ZINC EXPOSURE

    EPA Science Inventory

    Cardiovascular damage induced by pulmonary exposure to environmental chemicals can result from direct action or, secondarily, from pulmonary injury. We have developed a rat model of pulmonary exposure to zinc to demonstrate cardiac, coagulative, and fibrinolytic alterations. Mal...

  16. Comparison of functional aspects of the coagulation cascade in human and sea turtle plasmas.

    PubMed

    Soslau, Gerald; Wallace, Bryan; Vicente, Catherine; Goldenberg, Seth J; Tupis, Todd; Spotila, James; George, Robert; Paladino, Frank; Whitaker, Brent; Violetta, Gary; Piedra, Rotney

    2004-08-01

    Functional hemostatic pathways are critical for the survival of all vertebrates and have been evolving for more than 400 million years. The overwhelming majority of studies of hemostasis in vertebrates have focused on mammals with very sparse attention paid to reptiles. There have been virtually no studies of the coagulation pathway in sea turtles whose ancestors date back to the Jurassic period. Sea turtles are often exposed to rapidly altered environmental conditions during diving periods. This may reduce their blood pH during prolonged hypoxic dives. This report demonstrates that five species of turtles possess only one branch of the mammalian coagulation pathway, the extrinsic pathway. Mixing studies of turtle plasmas with human factor-deficient plasmas indicate that the intrinsic pathway factors VIII and IX are present in turtle plasma. These two factors may play a significant role in supporting the extrinsic pathway by feedback loops. The intrinsic factors, XI and XII are not detected which would account for the inability of reagents to induce coagulation via the intrinsic pathway in vitro. The analysis of two turtle factors, factor II (prothrombin) and factor X, demonstrates that they are antigenically/functionally similar to the corresponding human factors. The turtle coagulation pathway responds differentially to both pH and temperature relative to each turtle species and relative to human samples. The coagulation time (prothrombin time) increases as the temperature decreases between 37 and 15 degrees C. The increased time follows a linear relationship, with similar slopes for loggerhead, Kemps ridley and hawksbill turtles as well as for human samples. Leatherback turtle samples show a dramatic nonlinear increased time below 23 degrees C, and green turtle sample responses were similar but less dramatic. All samples also showed increased prothrombin times as the pH decreased from 7.8 to 6.4, except for three turtle species. The prothrombin times decreased, to varying extents, in a linear fashion relative to reduced pH with the rate of change greatest in leatherbacks>green>loggerhead turtles. All studies were conducted with reagents developed for human samples which would impact on the quantitative results with the turtle samples, but are not likely to alter the qualitative results. These comparative studies of the coagulation pathway in sea turtles and humans could enhance our knowledge of structure/function relationships and evolution of coagulation factors.

  17. Coagulation profile of Sudanese children with homozygous sickle cell disease and the effect of treatment with omega-3 fatty acid on the coagulation parameters.

    PubMed

    Awoda, Shiekh; Daak, Ahmed A; Husain, Nazik Elmalaika; Ghebremeskel, Kebreab; Elbashir, Mustafa I

    2017-01-01

    It has been reported that patients with SCD do have an abnormal coagulation profile. Coagulopathy is thought to be one of the key factors that contribute to the vaso-occlusive crisis that characterises sickle cell disease (SCD). In this study, we investigated whether Sudanese sickle cell patients have an abnormal coagulation profile. In addition, the effect of treatment with either omega-3 fatty acids or hydroxyurea on coagulation profile was assessed. Homozygous SCD patients untreated ( n  = 52), omega-3 treated ( n  = 44), hydroxyurea (HU) treated ( n  = 8) and healthy (HbAA) controls ( n  = 52) matched for age (4-20 years), gender and socioeconomic status were enrolled. Patients on omega-3 fatty acids, according to age, received one to four capsules containing 277.8 mg DHA and 39.0 mg eicosapentnoic. Patients on Hydroxyurea were in on dosage more than 20 mg/kg/day. The steady state levels of the coagulation parameters and the effect of the treatments with either HU or omega-3 fatty acids on markers of coagulation were investigated. Compared to the healthy controls, treated and untreated HbSS patients had lower hemoglobin, plasma Protein C, proteins S and higher white blood cell count (WBC), platelets count (PLTs) and plasma D-dimer levels,( p  < 0.05). In comparison to untreated HbSS, treatment with neither omega-3 nor HU had effect on the WBC, plasma proteins C and S, ( p  > 0.05). HU treated group had a lower PLTs count compared to HbSS untreated group ( p  < 0.5). The prothrombin and activated partial thromboplastin times and international normalized ratio (INR) of untreated patients are significantly higher than n-3 treated, HU-treated patients and health controls, ( p  < 0.05). Patients treated with omega-3 had lowered D-dimer levels in comparison to HU-treated and untreated HbSS patients, ( p  < 0.001). This study provides evidence that Sudanes patients have abnormal coagulation profile and treatment with either HU or omega-3 fatty acids might partially ameliorate SCD-associated chronic coagulopathic state.

  18. A quantitative systems pharmacology model of blood coagulation network describes in vivo biomarker changes in non-bleeding subjects.

    PubMed

    Lee, D; Nayak, S; Martin, S W; Heatherington, A C; Vicini, P; Hua, F

    2016-12-01

    Essentials Baseline coagulation activity can be detected in non-bleeding state by in vivo biomarker levels. A detailed mathematical model of coagulation was developed to describe the non-bleeding state. Optimized model described in vivo biomarkers with recombinant activated factor VII treatment. Sensitivity analysis predicted prothrombin fragment 1 + 2 and D-dimer are regulated differently. Background Prothrombin fragment 1 + 2 (F 1 + 2 ), thrombin-antithrombin III complex (TAT) and D-dimer can be detected in plasma from non-bleeding hemostatically normal subjects or hemophilic patients. They are often used as safety or pharmacodynamic biomarkers for hemostatis-modulating therapies in the clinic, and provide insights into in vivo coagulation activity. Objectives To develop a quantitative systems pharmacology (QSP) model of the blood coagulation network to describe in vivo biomarkers, including F 1 + 2 , TAT, and D-dimer, under non-bleeding conditions. Methods The QSP model included intrinsic and extrinsic coagulation pathways, platelet activation state-dependent kinetics, and a two-compartment pharmacokinetics model for recombinant activated factor VII (rFVIIa). Literature data on F 1 + 2 and D-dimer at baseline and changes with rFVIIa treatment were used for parameter optimization. Multiparametric sensitivity analysis (MPSA) was used to understand key proteins that regulate F 1 + 2 , TAT and D-dimer levels. Results The model was able to describe tissue factor (TF)-dependent baseline levels of F 1 + 2 , TAT and D-dimer in a non-bleeding state, and their increases in hemostatically normal subjects and hemophilic patients treated with different doses of rFVIIa. The amount of TF required is predicted to be very low in a non-bleeding state. The model also predicts that these biomarker levels will be similar in hemostatically normal subjects and hemophilic patients. MPSA revealed that F 1 + 2 and TAT levels are highly correlated, and that D-dimer is more sensitive to the perturbation of coagulation protein concentrations. Conclusions A QSP model for non-bleeding baseline coagulation activity was established with data from clinically relevant in vivo biomarkers at baseline and changes in response to rFVIIa treatment. This model will provide future mechanistic insights into this system. © 2016 International Society on Thrombosis and Haemostasis.

  19. Formation of planetesimals

    NASA Technical Reports Server (NTRS)

    Weidenschilling, Stuart J.

    1991-01-01

    Formation of planetesimals is discussed. The following subject areas are covered: (1) nebular structure; (2) aerodynamics of the solid bodies in the nebula; (3) problems with gravitational instability; (4) particle growth by coagulation; properties of fractal aggregates; and (5) coagulation and settling of fractal aggregates.

  20. The use of smoke acid as an alternative coagulating agent for natural rubber sheets' production.

    PubMed

    Ferreira, Vanda S; Rêgo, Ione N C; Pastore, Floriano; Mandai, Mariana M; Mendes, Leonardo S; Santos, Karin A M; Rubim, Joel C; Suarez, Paulo A Z

    2005-03-01

    A comparative study of rubber sheets obtained using formic, acetic, and smoke acid as coagulants is shown for latex obtained from native Amazonian trees and also from commercial cultivated trees. The evaluation of both processes of coagulation was carried out by spectroscopic and physical-chemical analysis, showing no differences in the rubber sheets obtained. This new method of rubber sheet preparation was introduced into Amazonian rainforest rubber tapper communities, which are actually producing in large scale. The physical-mechanical properties were similar among a large sheets made by different rubber tapper communities using this new method.

  1. Organic polyelectrolytes in water treatment.

    PubMed

    Bolto, Brian; Gregory, John

    2007-06-01

    The use of polymers in the production of drinking water is reviewed, with emphasis on the nature of the impurities to be removed, the mechanisms of coagulation and flocculation, and the types of polymers commonly available. There is a focus on polymers for primary coagulation, their use as coagulant aids, in the recycling of filter backwash waters, and in sludge thickening. Practicalities of polymer use are discussed, with particular attention to polymer toxicity, and the presence of residual polymer in the final drinking water. The questions of polymer degradation and the formation of disinfection by-products are also addressed.

  2. A comparative analysis of selected wastewater pretreatment processes in food industry

    NASA Astrophysics Data System (ADS)

    Jaszczyszyn, Katarzyna; Góra, Wojciech; Dymaczewski, Zbysław; Borowiak, Robert

    2018-02-01

    The article presents a comparative analysis of the classical coagulation with the iron sulphate and adsorption on bentonite for the pretreatment of wastewater in the food industry. As a result of the studies, chemical oxygen demand (COD) and total nitrogen (TN) reduction were found to be comparable in both technologies, and a 29% higher total phosphorus removal efficiency by the coagulation was observed. After the coagulation and adsorption processes, a significant difference between mineral and organic fraction in the sludge was found (49% and 51% for bentonite and 28% and 72% for iron sulphate, respectively).

  3. [Chemotherapy in combination with laser coagulation or interstitial hyperthermia--effective combined therapy for disseminated skin melanoma].

    PubMed

    Akimov, M A; Gel'fond, M L; Gershanovich, M L; Barchuk, A S

    2003-01-01

    Thirty-eight patients with disseminated skin melanoma received chemotherapy in conjunction with laser coagulation or interstitial hyperthermia of intra- or subcutaneous metastases. Use of combination therapy was followed by a rise to 37% in total response and 16%--complete regression, respectively. Most effectiveness was attained when the dacarbazine + cisplatin + BCNU + tamoxifen regime was employed. In this group of 16 patients (46%), total response was 56% and, what is most significant, 31% in complete regression. In all cases of apparent response, polychemotherapy was administered both before and after laser coagulation or interstitial hyperthermia.

  4. Magnetic cellulose-derivative structures

    DOEpatents

    Walsh, M.A.; Morris, R.S.

    1986-09-16

    Structures to serve as selective magnetic sorbents are formed by dissolving a cellulose derivative such as cellulose triacetate in a solvent containing magnetic particles. The resulting solution is sprayed as a fine mist into a chamber containing a liquid coagulant such as n-hexane in which the cellulose derivative is insoluble but in which the coagulant is soluble or miscible. On contact with the coagulant, the mist forms free-flowing porous magnetic microspheric structures. These structures act as containers for the ion-selective or organic-selective sorption agent of choice. Some sorption agents can be incorporated during the manufacture of the structure. 3 figs.

  5. Magnetic cellulose-derivative structures

    DOEpatents

    Walsh, Myles A.; Morris, Robert S.

    1986-09-16

    Structures to serve as selective magnetic sorbents are formed by dissolving a cellulose derivative such as cellulose triacetate in a solvent containing magnetic particles. The resulting solution is sprayed as a fine mist into a chamber containing a liquid coagulant such as n-hexane in which the cellulose derivative is insoluble but in which the coagulant is soluble or miscible. On contact with the coagulant, the mist forms free-flowing porous magnetic microspheric structures. These structures act as containers for the ion-selective or organic-selective sorption agent of choice. Some sorbtion agents can be incorporated during the manufacture of the structure.

  6. Competitive adsorption of PPCP and humic substances by carbon nanotube membranes: Effects of coagulation and PPCP properties.

    PubMed

    Wang, Yifei; Yang, Qing; Dong, Junqing; Huang, Haiou

    2018-04-01

    Natural organic matter (NOM) and pharmaceuticals and personal care products (PPCP) are known to compete for adsorption sites on carbon nanotubes (CNT), resulting in decreasing PPCP adsorption onto CNT. In this study, four types of PPCP, as such acetaminophen (AAP), caffeine (CAF), triclosan (TCS), and carbendazim (CBD) were used to investigate the effects of PPCP properties and NOM coagulation on the competitive adsorption of PPCP and NOM. Coagulation preferentially removed HS from a natural surface water, thereby increasing adsorption of AAP, CAF, TCS and CBD by 19%, 13%, 17% and 11%, respectively. Similar trends were obtained with synthetic natural waters, for which the adsorption of AAP, CAF, TCS, and CBD increased by 29%, 7%, 44% and 69%, respectively, as humic acid (HA) concentration decreased from 10mgL -1 to 0mgL -1 . Furthermore, PPCP properties also affected their competition with NOM for adsorption by CNT membranes Because CAF existed in cationic form at pH ranging from 7 to 8.3, its adsorption was less affected by the presence/coagulation of NOM than AAP, CBD, and TCS. Based upon these findings, coagulation has the potential to be integrated with CNT adsorption for the removal of PPCP compounds during advanced drinking water treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Low-level lasers: their role in the mechanisms of the stimulation of the reparative processes

    NASA Astrophysics Data System (ADS)

    Yeliseenko, Vladimir I.

    1994-08-01

    The transformation of light energy into thermal energy with extremely high temperatures, the evaporation of interstitial and intracellular fluids, and the cytoplasmic proteins coagulation are the most important factors in the mechanism of high-power lasers effect on biological tissues. A set of dystrophic disorders develops in tissues as a result, up to the coagulative necrosis, which lays in the basis of the laser thermal crust at incised edges. With CO2 laser the damage is evident from the first cell layers. Its size is in the linear correlation with exposure time. The Nd:YAG and argon lasers' light penetrates the superficial cell layers without damage practically and realizes in deeper well vascularized tissue layers, the submucous layer of the gastrointestinal hollow organs, in particular. It depends on the closeness of the irradiation spectrum of absorption of hemoglobin and result in blood coagulation in the vascular lumine with formation of the `coagulative laser thrombi.' That explains a wide use of laser irradiation in urgent endoscopy for arresting acute gastrointestinal hemorrhages. For these reasons Nd:YAG laser `contact scalpel' technique with sapphire tips is used for incisions on parenchymatous organs with simultaneous blood coagulation in vessels lumina with good hemostasis and holestasis (hepatobiliar surgery), and for pancreas and thyroid surgery, in gynecology and other surgical areas.

  8. Critical assessment of chitosan as coagulant to remove cyanobacteria.

    PubMed

    Lürling, Miquel; Noyma, Natalia Pessoa; de Magalhães, Leonardo; Miranda, Marcela; Mucci, Maíra; van Oosterhout, Frank; Huszar, Vera L M; Marinho, Marcelo Manzi

    2017-06-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial blooms, as well as high alkalinity may hamper the coagulation of chitosan and thus impair its ability to effectively remove positively buoyant cyanobacteria from the water column. The underlying mechanism is likely a shielding of the protonated groups by anions. Inasmuch as there are many chitosan formulations, thorough testing of each chitosan prior to its application is essential. Results obtained in glass tubes were similar to those from standard jar tests demonstrating that glass tube tests can be used for testing effects of coagulants and ballasts in cyanobacteria removal whilst allowing far more replicates. There was no relation between zeta potential and precipitated cyanobacteria. Given the well-known antibacterial activity of chitosan and recent findings of anti-cyanobacterial effects, pre-application tests are needed to decipher if chitosan may cause cell leakage of cyanotoxins. Efficiency- and side-effect testing are crucial for water managers to determine if the selected approach can be used in tailor-made interventions to control cyanobacterial blooms and to mitigate eutrophication. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Blood coagulation using High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Nguyen, Phuc V.; Oh, Junghwan; Kang, Hyun Wook

    2014-03-01

    High Intensity Focused Ultrasound (HIFU) technology provides a feasible method of achieving thermal coagulation during surgical procedures. One of the potential clinical benefits of HIFU can induce immediate hemostasis without suturing. The objective of this study was to investigate the efficiency of a HIFU system for blood coagulation on severe vascular injury. ngHIFU treatment was implemented immediately after bleeding in artery. The ultrasound probe was made of piezoelectric material, generating a central frequency of 2.0 MHz as well as an ellipsoidal focal spot of 2 mm in lateral dimension and 10 mm in axial dimension. Acoustic coagulation was employed on a perfused chicken artery model in vitro. A surgical incision (1 to 2 mm long) was made with a scapel on the arterial wall, and heparinized autologous blood was made to leak out from the incision with a syringe pump. A total of 5 femoral artery incisions was treated with the HIFU beam. The intensity of 4500 W/cm2 at the focus was applied for all treatments. Complete hemostasis was achieved in all treatments, along with the treatment times of 25 to 50 seconds. The estimated intraoperative blood loss was from 2 to 5 mL. The proposed HIFU system may provide an effective method for immediate blood coagulation for arteries and veins in clinical applications.

  10. Restoration of water environment contaminated by radioactive cesium released from Fukushima Daiichi NPP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeshita, K.; Takahashi, H.; Jinbo, Y.

    2013-07-01

    In the Fukushima Daiichi NPP Accident, large amounts of volatile radioactive nuclides, such as {sup 131}I, {sup 134}Cs and {sup 137}Cs, were released to the atmosphere and huge areas surrounding the nuclear site were contaminated by the radioactive fallout. In this study, a combined process with a hydrothermal process and a coagulation settling process was proposed for the separation of radioactive Cs from contaminated soil and sewage sludge. The coagulation settling operation uses Prussian Blue (Ferric ferrocyanide) and an inorganic coagulant. The recovery of Cs from sewage sludge sampled at Fukushima city (100.000 Bq/kg) and soil at a nearby villagemore » (55.000 Bq/kg), was tested. About 96% of Cs in the sewage sludge was removed successfully by combining simple hydrothermal decomposition and coagulation settling. However, Cs in the soil was not removed sufficiently by the combined process (Cs removal is only 56%). The hydrothermal decomposition with blasting was carried out. The Cs removal from the soil was increased to 85%. When these operations were repeated twice, the Cs recovery was over 90%. The combined process with hydrothermal blasting and coagulation settling is applicable to the removal of Cs from highly contaminated soil.« less

  11. A method for the inline measurement of milk gel firmness using an optical sensor.

    PubMed

    Arango, O; Castillo, M

    2018-05-01

    At present, selection of cutting time during cheesemaking is made based on subjective methods, which has effects on product homogeneity and has prevented complete automation of cheesemaking. In this work, a new method for inline monitoring of curd firmness is presented. The method consisted of developing a model that correlates the backscatter ratio of near infrared light during milk coagulation with the rheological storage modulus. The model was developed through a factorial design with 2 factors: protein concentration (3.4 and 5.1%) and coagulation temperature (30 and 40°C). Each treatment was replicated 3 times; the model was calibrated with the first replicate and validated using the remaining 2 replicates. The coagulation process was simultaneously monitored using an optical sensor and small-amplitude oscillatory rheology. The model was calibrated and successfully validated at the different protein concentrations and coagulation temperatures studied, predicting the evolution of storage modulus during milk coagulation with coefficient of determination values >0.998 and standard error of prediction values <3.4 Pa. The results demonstrated that the proposed method allows inline monitoring of curd firming in cheesemaking and cutting the curd at a proper firmness to each type of cheese. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Restoration of tensile strength in bark samples of Ficus benjamina due to coagulation of latex during fast self-healing of fissures

    PubMed Central

    Bauer, Georg; Speck, Thomas

    2012-01-01

    Background and Aims The functions of plant latex have been discussed for a long time. Today, many studies support a defence mechanism as being its main function. A role as a self-healing mechanism was never attributed to the coagulation of latex. In this study we quantified the contribution of the coagulation of Ficus benjamina (weeping fig) latex to a restoration of the mechanical properties of the bark after external lesions. Methods Tensile tests of F. benjamina bark were conducted either immediately after injury or at various latency times after injury. Key Results A significant increase in the tensile strength of bark samples until 30 min after injury was found, and this effect could be attributed to the coagulation of plant latex alone. The tensile strength remains nearly constant until several hours or days after injury. Then, very probably due to other mechanisms such as cell growth and cell proliferation, the tensile strength begins to increase slightly again. Conclusions The coagulation of latex seals lesions and serves as a quick and effective pre-step of subsequent, more effective, long-lasting self-healing mechanisms such as cell growth and proliferation. Thus, a fast self-healing effect can be included in the list of functions of plant latex. PMID:22207613

  13. Restoration of tensile strength in bark samples of Ficus benjamina due to coagulation of latex during fast self-healing of fissures.

    PubMed

    Bauer, Georg; Speck, Thomas

    2012-03-01

    The functions of plant latex have been discussed for a long time. Today, many studies support a defence mechanism as being its main function. A role as a self-healing mechanism was never attributed to the coagulation of latex. In this study we quantified the contribution of the coagulation of Ficus benjamina (weeping fig) latex to a restoration of the mechanical properties of the bark after external lesions. Tensile tests of F. benjamina bark were conducted either immediately after injury or at various latency times after injury. A significant increase in the tensile strength of bark samples until 30 min after injury was found, and this effect could be attributed to the coagulation of plant latex alone. The tensile strength remains nearly constant until several hours or days after injury. Then, very probably due to other mechanisms such as cell growth and cell proliferation, the tensile strength begins to increase slightly again. The coagulation of latex seals lesions and serves as a quick and effective pre-step of subsequent, more effective, long-lasting self-healing mechanisms such as cell growth and proliferation. Thus, a fast self-healing effect can be included in the list of functions of plant latex.

  14. Experimental dosing of wetlands with coagulants removes mercury from surface water and decreases mercury bioaccumulation in fish

    USGS Publications Warehouse

    Ackerman, Joshua T.; Kraus, Tamara E.C.; Fleck, Jacob A.; Krabbenhoft, David P.; Horwarth, William R.; Bachand, Sandra M.; Herzog, Mark; Hartman, Christopher; Bachand, Philip A.M.

    2015-01-01

    Mercury pollution is widespread globally, and strategies for managing mercury contamination in aquatic environments are necessary. We tested whether coagulation with metal-based salts could remove mercury from wetland surface waters and decrease mercury bioaccumulation in fish. In a complete randomized block design, we constructed nine experimental wetlands in California’s Sacramento–San Joaquin Delta, stocked them with mosquitofish (Gambusia affinis), and then continuously applied agricultural drainage water that was either untreated (control), or treated with polyaluminum chloride or ferric sulfate coagulants. Total mercury and methylmercury concentrations in surface waters were decreased by 62% and 63% in polyaluminum chloride treated wetlands and 50% and 76% in ferric sulfate treated wetlands compared to control wetlands. Specifically, following coagulation, mercury was transferred from the filtered fraction of water into the particulate fraction of water which then settled within the wetland. Mosquitofish mercury concentrations were decreased by 35% in ferric sulfate treated wetlands compared to control wetlands. There was no reduction in mosquitofish mercury concentrations within the polyaluminum chloride treated wetlands, which may have been caused by production of bioavailable methylmercury within those wetlands. Coagulation may be an effective management strategy for reducing mercury contamination within wetlands, but further studies should explore potential effects on wetland ecosystems.

  15. Size-Resolved Ultrafine Particle Deposition and Brownian Coagulation from Gasoline Vehicle Exhaust in an Environmental Test Chamber.

    PubMed

    Zhao, Yu; Wang, Fang; Zhao, Jianing

    2015-10-20

    Size-resolved deposition rates and Brownian coagulation of particles between 20 and 900 nm (mobility diameter) were estimated in a well-mixed environmental chamber from a gasoline vehicle exhaust with a total peak particle concentration of 10(5)-10(6) particles/cm(3) at 12.24-25.22 °C. A deposition theory with modified friction velocity and coagulation model was also employed to predict particle concentration decay. Initially during particle decay, approximately 85% or more of the particles had diameters of <100 nm. Particle deposition rates with standard deviations were highly dependent on particle size ranges, and varied from 0.012 ± 0.003 to 0.48 ± 0.02 h(-1). In the experiment, the friction velocity obtained was in the range 1.5-2.5 cm/s. The most explainable fractal dimension and Hamaker constant in coagulation model were 2.5-3 and 20 kT, respectively, and the contribution from coagulation dominated the total particle decay during the first 1 h of decay. It is considered that the modified friction velocity and best fitted fractal dimension and Hamaker constants could be further used to analyze gasoline vehicle exhaust particle dynamics and assess human exposure to vehicle particle pollutants in urban areas, tunnels, and underground parking lots.

  16. The role of leukotoxin (9,10-epoxy-12-octadecenoate) in the genesis of coagulation abnormalities.

    PubMed

    Sugiyama, S; Hayakawa, M; Hanaki, Y; Hieda, N; Asai, J; Ozawa, T

    1988-01-01

    This study was designed to clarify whether or not leukotoxin (9, 10-epoxy-12-octadecenoate), which is biosynthesized by neutrophils, might be involved in the genesis of coagulating abnormalities. Twelve dogs were divided into 2 groups. In the test group (n = 6), 100 mumol/kg of leukotoxin was injected intravenously, and in the control group (n = 6), 100 mumol/kg of linoleate was injected. In each group, a series of blood samples were collected and used for coagulation studies. After the end of the experimental period, a histological study was performed on organs removed from the dogs. In the leukotoxin group, fibrin and fibrinogen degradation products (FDP) was increased time-dependently. Fibrinogen was decreased, and prothrombin time and activated partial thromboplastin time were prolonged in parallel with the increase in FDP. A decrease in number of platelets was also observed. Intravascular coagulation was observed in sections of lung. These data were compatible with a diagnosis of disseminated intravascular coagulation (DIC). No significant changes in these parameters were observed in the linoleate group. Leukotoxin has been confirmed to show antifungal and antibacterial activity, and its production might be a defensive response to infection. Over-production of leukotoxin associated with severe infection might therefore account for infection-induced DIC.

  17. Research of combined adsorption-coagulation process in treating petroleum refinery effluent.

    PubMed

    Wang, Bing; Shui, Yiyu; Ren, Hongyang; He, Min

    2017-02-01

    The petroleum refinery industry generates a significant amount of wastewater that contains a high level of organic matter, which calls for effective and costly treatments. In this research, the effectiveness of the petroleum refinery effluent (PRE) treatment with physicochemical process of combined adsorption and coagulation was evaluated. The effects of initial pH, hydraulic condition , and combined sequence of treatment process, different treating reagent types and dosages on the chemical oxygen demand (COD) removal were investigated. Additionally, the elimination efficiency of pollutant wastewater was monitored by gas chromatography-mass spectrometry (GC-MS), and Fourier transformed infrared (FT-IR) spectrophotometer was adopted to describe the structure of the wastewater. Wooden activated carbon was chosen as adsorbent at the dosage of 10 g/L as a primary treatment, and 1500 mg/L polymeric magnesium ferric sulfate was used in coagulation. Results showed that adsorption and subsequent coagulation displayed the best performance when initial pH was 9 at shear rates (G) of G1 = 65 s -1 and G2 = 20 s -1 , which reached maximal removal rate of COD and total organic carbon GC-MS testing result revealed that adsorption was effective in phenols and iso-alkanes removal, whereas coagulation was good at removing esters and n-alkanes.

  18. The fibrinogen/CRP ratio as a new parameter for the diagnosis of disseminated intravascular coagulation in patients with HELLP syndrome and as a predictive factor for neonatal outcome.

    PubMed

    Windsperger, Karin; Lehner, Rainer

    2013-02-01

    The aim of this study was to determine if the fibrinogen/C-reactive protein (CRP) ratio could be used in obstetrics as a predictor for a disseminated intravascular coagulation. One hundred eleven patients with hemolysis, elevated liver enzymes, and low platelet count syndrome at the Department of Obstetrics and Fetomaternal Medicine (General Hospital, Vienna, Austria) were selected and divided into 2 groups (overt disseminated intravascular coagulation, no overt disseminated intravascular coagulation). The classical parameters and the fibrinogen/CRP ratio were compared. The analysis was carried out using IBM SPSS statistical package (SPSS, Inc, Cary, NC). The fibrinogen/CRP ratio showed significant differences. The receiver-operating characteristic analysis showed for the ratio (area under the curve, 0.74) significantly better discriminative power than for fibrinogen (area under curve, 0.59). The odds ratio for the fibrinogen/CRP ratio was 7.04. Finally, significant correlations between the ratio and the neonatal outcome were found. We suggest the implementation of the fibrinogen/CRP ratio within patients with hemolysis, elevated liver enzymes, and low platelet count syndrome as a diagnostic and prognostic factor for the occurrence of disseminated intravascular coagulation. Copyright © 2013 Mosby, Inc. All rights reserved.

  19. Polyaluminium chloride as an alternative to alum for the direct filtration of drinking water.

    PubMed

    Zarchi, Idit; Friedler, Eran; Rebhun, Menahem

    2013-01-01

    The efficiency of various polyaluminium chloride coagulants (PACls) was compared to the efficiency of aluminium sulfate (alum) in the coagulation-flocculation process preceding direct filtration in drinking water treatment. The comparative study consisted of two separate yet complementary series of experiments: the first series included short (5-7 h) and long (24 h) filter runs conducted at a pilot filtration plant equipped with large filter columns that simulated full-scale filters. Partially treated surface water from the Sea of Galilee, characterized by very low turbidity (-1 NTU), was used. In the second series of experiments, speciation of aluminium in situ was investigated using the ferron assay method. Results from the pilot-scale study indicate that most PACls were as or more efficient a coagulant as alum for direct filtration of surface water without requiring acid addition for pH adjustment and subsequent base addition for re-stabilizing the water. Consequently, cost analysis of the chemicals needed for the process showed that treatment with PACl would be significantly less costly than treatment with alum. The aluminium speciation experiments revealed that the performance of the coagulant is more influenced by the species present during the coagulation process than those present in the original reagents.

  20. Coagulation efficiency and flocs characteristics of recycling sludge during treatment of low temperature and micro-polluted water.

    PubMed

    Zhou, Zhiwei; Yang, Yanling; Li, Xing; Gao, Wei; Liang, Heng; Li, Guibai

    2012-01-01

    Drinking water treatment sludge, characterized as accumulated suspended solids and organic and inorganic matter, is produced in large quantities during the coagulation process. The proper disposal, regeneration or reuse of sludge is, therefore, a significant environmental issue. Reused sludge at low temperatures is an alternative method to enhance traditional coagulation efficiency. In the present study, the recycling mass of mixed sludge and properties of raw water (such as pH and turbidity) were systematically investigated to optimize coagulation efficiency. We determined that the appropriate dosage of mixed sludge was 60 mL/L, effective initial turbidity ranges were below 45.0 NTU, and optimal pH for DOMs and turbidity removal was 6.5-7.0 and 8.0, respectively. Furthermore, by comparing the flocs characteristics with and without recycling sludge, we found that floc structures with sludge were more irregular with average size growth to 64.7 microm from 48.1 microm. Recycling sludge was a feasible and successful method for enhancing pollutants removal, and the more irregular flocs structure after recycling might be caused by breakage of reused flocs and incorporation of powdered activated carbon into larger flocs structure. Applied during the coagulation process, recycling sludge could be significant for the treatment of low temperature and micro-polluted source water.

Top