Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.
Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre
2017-09-01
It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.
Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.
Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric
2015-09-01
Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.
Sequential Bilateral Cochlear Implantation in a Patient with Bilateral Meniere’s Disease
Holden, Laura K.; Neely, J. Gail; Gotter, Brenda D.; Mispagel, Karen M.; Firszt, Jill B.
2012-01-01
This case study describes a 45 year old female with bilateral, profound sensorineural hearing loss due to Meniere’s disease. She received her first cochlear implant in the right ear in 2008 and the second cochlear implant in the left ear in 2010. The case study examines the enhancement to speech recognition, particularly in noise, provided by bilateral cochlear implants. Speech recognition tests were administered prior to obtaining the second implant and at a number of test intervals following activation of the second device. Speech recognition in quiet and noise as well as localization abilities were assessed in several conditions to determine bilateral benefit and performance differences between ears. The results of the speech recognition testing indicated a substantial improvement in the patient’s ability to understand speech in noise and her ability to localize sound when using bilateral cochlear implants compared to using a unilateral implant or an implant and a hearing aid. In addition, the patient reported considerable improvement in her ability to communicate in daily life when using bilateral implants versus a unilateral implant. This case suggests that cochlear implantation is a viable option for patients who have lost their hearing to Meniere’s disease even when a number of medical treatments and surgical interventions have been performed to control vertigo. In the case presented, bilateral cochlear implantation was necessary for this patient to communicate successfully at home and at work. PMID:22463939
Physiopathology of the cochlear microcirculation.
Shi, Xiaorui
2011-12-01
Normal blood supply to the cochlea is critically important for establishing the endocochlear potential and sustaining production of endolymph. Abnormal cochlear microcirculation has long been considered an etiologic factor in noise-induced hearing loss, age-related hearing loss (presbycusis), sudden hearing loss or vestibular function, and Meniere's disease. Knowledge of the mechanisms underlying the pathophysiology of cochlear microcirculation is of fundamental clinical importance. A better understanding of cochlear blood flow (CoBF) will enable more effective management of hearing disorders resulting from aberrant blood flow. This review focuses on recent discoveries and findings related to the physiopathology of the cochlear microvasculature. Published by Elsevier B.V.
Physiopathology of the Cochlear Microcirculation
Shi, Xiaorui
2011-01-01
Normal blood supply to the cochlea is critically important for establishing the endocochlear potential and sustaining production of endolymph. Abnormal cochlear microcirculation has long been considered an etiologic factor in noise-induced hearing loss, age-related hearing loss (presbycusis), sudden hearing loss or vestibular function, and Meniere's disease. Knowledge of the mechanisms underlying the pathophysiology of cochlear microcirculation is of fundamental clinical importance. A better understanding of cochlear blood flow (CoBF) will enable more effective management of hearing disorders resulting from aberrant blood flow. This review focuses on recent discoveries and findings related to the physiopathology of the cochlear microvasculature. PMID:21875658
Cochlear Implantation in Siblings With Refsum's Disease.
Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana
2017-08-01
Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.
The Association between Cardiovascular Disease and Cochlear Function in Older Adults
ERIC Educational Resources Information Center
Torre, Peter, III; Cruickshanks, Karen J.; Klein, Barbara E.K.; Klein, Ronald; Nondahl, David M.
2005-01-01
The purpose of this research was to evaluate the relation between self-reported cardiovascular disease (CVD) and cochlear function in older adults. The Epidemiology of Hearing Loss Study (EHLS) is an ongoing population-based study of hearing loss and its risk factors in Beaver Dam, Wisconsin. As part of the EHLS questionnaire, participants were…
A new disease: pregnancy-induced sudden sensorineural hearing loss?
Hou, Zhi-Qiang; Wang, Qiu-Ju
2011-07-01
Sudden sensorineural hearing loss (SSNHL) may occur during pregnancy, but its prevalence is very low. It is conjectured that SSNHL is closely related to the changes in the cardiovascular system, hematological system, endocrine system, and/or some other systems due to pregnancy. These changes possibly evoke disorders of cochlear circulation or cochlear fluid homeostasis leading to SSNHL. Two SSNHL cases were observed in our clinic, and their clinical features were analyzed. In one patient the SSNHL was likely to be related to the disturbance of cochlear fluid homestasis and in the other it might be induced by some disorders in cochlear circulation. Based on their distinct clinic profiles, we defined a new disease, called "pregnancy-induced sudden sensorineural hearing loss," similar to the definition of "pregnancy-induced hypertension." This study also deepened our understanding of the etiology of SSNHL.
Luzzi, R; Belcaro, G; Hu, S; Dugall, M; Hosoi, M; Cacchio, M; Ippolito, E; Corsi, M
2014-06-01
The aim of this supplement registry was to evaluate the efficacy of the Pycnogenol® in improving cochlear flow and symptoms in a 6-month follow-up for patients with Meniere's disease (MD), tinnitus and cochlear hypoperfusion. Main signs/symptoms were considered: Spontaneous vertigo, positional vertigo, hearing loss, tinnitus, pressure in the ear, unsteady gait, associated clinical problems, alterations in daily life. All subjects were managed with the best available management (BM); one group used the supplement Pycnogenol (150 mg/day). Cochlear flow and tinnitus were also evaluated. Out of 120 patients incuded in the registry, 55 used Pycnogenol and 52 (controls) were managed only with BM. There was a more significant improvement in all registry items at 3 and 6 months in the Pycnogenol group (P<0.05). The number of lost working days was lower in the Pycnogenol group. At 3 months, 45.4% of subjects using Pycnogenol were completely asymptomatic in comparison with 23.07% of controls. At 6 months 87.3% of the Pycnogenol subjects were asymptomatic compared with 34.6% of controls. Cochlear flow velocity was significantly better (higher flow, higher diastolic component) in the Pycnogenol group (P<0.05). The subjective tinnitus scale decreased in both groups (P<0.05); the decrease was more significant in Pycnogenol subjects (P<0.05) at 3 and 6 months. Symptoms of Meniere's disease, flow at cochlear level and tinnitus improved in Pycnogenol subjects in comparison with best management.
Scala vestibuli cochlear implantation in patients with partially ossified cochleas.
Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari
2002-11-01
Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.
Bertlich, Mattis; Ihler, Fritz; Sharaf, Kariem; Weiss, Bernhard G; Strupp, Michael; Canis, Martin
2014-10-01
Betahistine is a histamine-like drug that is used in the treatment of Ménière's disease. It is commonly believed that betahistine increases cochlear blood flow and thus decreases the endolymphatic hydrops that is the cause of Ménière's. Despite common clinical use, there is little understanding of the kinetics or effects of its metabolites. This study investigated the effect of the betahistine metabolites aminoethylpyridine, hydroxyethylpyridine, and pyridylacetic acid on cochlear microcirculation. Guinea pigs were randomly assigned to one of the groups: placebo, betahistine, or equimolar amounts of aminoethylpyridine, hydroxyethylpyridine, or pyridylacetic acid. Cochlear blood flow and mean arterial pressure were recorded for three minutes before and 15 minutes after treatment. Thirty Dunkin-Hartley guinea pigs assigned to one of five groups with six guinea pigs per group. Betahistine, aminoethylpyridine, and hydroxyethylpyridine caused a significant increase in cochlear blood flow in comparison to placebo. The effect seen under aminoethylpyridin was greatest. The group treated with pyridylacetic acid showed no significant effect on cochlear blood flow. Aminoethylpyridine and hydroxyethylpyridine are, like betahistine, able to increase cochlear blood flow significantly. The effect of aminoethylpyridine was greatest. Pyridylacetic acid had no effect on cochlear microcirculation.
Bertlich, Mattis; Ihler, Friedrich; Freytag, Saskia; Weiss, Bernhard G; Strupp, Michael; Canis, Martin
2015-01-01
Betahistine is a histamine-like drug that is considered beneficial in Ménière's disease by increasing cochlear blood flow. Acting as an agonist at the histamine H1-receptor and as an inverse agonist at the H3-receptor, these receptors as well as the adrenergic α2-receptor were investigated for betahistine effects on cochlear blood flow. A total of 54 Dunkin-Hartley guinea pigs were randomly assigned to one of nine groups treated with a selection of H1-, H3- or α2-selective agonists and antagonists together with betahistine. Cochlear blood flow and mean arterial pressure were recorded for 3 min before and 15 min after infusion. Blockage of the H3- or α2-receptors caused a suppression of betahistine-mediated typical changes in cochlear blood flow or blood pressure. Activation of H3-receptors caused a drop in cochlear blood flow and blood pressure. H1-receptors showed no involvement in betahistine-mediated changes of cochlear blood flow. Betahistine most likely affects cochlear blood flow through histaminergic H3-heteroreceptors. © 2015 S. Karger AG, Basel.
Ihler, Fritz; Bertlich, Mattis; Sharaf, Kariem; Strieth, Sebastian; Strupp, Michael; Canis, Martin
2012-01-01
Betahistine is a histamine H(1)-receptor agonist and H(3)-receptor antagonist that is administered to treat Menière's disease. Despite widespread use, its pharmacological mode of action has not been entirely elucidated. This study investigated the effect of betahistine on guinea pigs at dosages corresponding to clinically used doses for cochlear microcirculation. Thirty healthy Dunkin-Hartley guinea pigs were randomly assigned to five groups to receive betahistine dihydrochloride in a dose of 1,000 mg/kg b. w. (milligram per kilogram body weight), 0.100 mg/kg b. w., 0.010 mg/kg b. w., 0.001 mg/kg b. w. in NaCl 0.9% or NaCl 0.9% alone as placebo. Cochlear blood flow and mean arterial pressure were continuously monitored by intravital fluorescence microscopy and invasive blood pressure measurements 3 minutes before and 15 minutes after administration of betahistine. When betahistine was administered in a dose of 1.000 mg/kg b. w. cochlear blood flow was increased to a peak value of 1.340 arbitrary units (SD: 0.246; range: 0.933-1.546 arb. units) compared to baseline (p<0.05; Two Way Repeated Measures ANOVA/Bonferroni t-test). The lowest dosage of 0.001 mg/kg b. w. betahistine or NaCl 0.9% had the same effect as placebo. Nonlinear regression revealed that there was a sigmoid correlation between increase in blood flow and dosages. Betahistine has a dose-dependent effect on the increase of blood flow in cochlear capillaries. The effects of the dosage range of betahistine on cochlear microcirculation corresponded well to clinically used single dosages to treat Menière's disease. Our data suggest that the improved effects of higher doses of betahistine in the treatment of Menière's disease might be due to a corresponding increase of cochlear blood flow.
Ihler, Fritz; Bertlich, Mattis; Sharaf, Kariem; Strieth, Sebastian
2012-01-01
Objective Betahistine is a histamine H1-receptor agonist and H3-receptor antagonist that is administered to treat Menière’s disease. Despite widespread use, its pharmacological mode of action has not been entirely elucidated. This study investigated the effect of betahistine on guinea pigs at dosages corresponding to clinically used doses for cochlear microcirculation. Methods Thirty healthy Dunkin-Hartley guinea pigs were randomly assigned to five groups to receive betahistine dihydrochloride in a dose of 1,000 mg/kg b. w. (milligram per kilogram body weight), 0.100 mg/kg b. w., 0.010 mg/kg b. w., 0.001 mg/kg b. w. in NaCl 0.9% or NaCl 0.9% alone as placebo. Cochlear blood flow and mean arterial pressure were continuously monitored by intravital fluorescence microscopy and invasive blood pressure measurements 3 minutes before and 15 minutes after administration of betahistine. Results When betahistine was administered in a dose of 1.000 mg/kg b. w. cochlear blood flow was increased to a peak value of 1.340 arbitrary units (SD: 0.246; range: 0.933–1.546 arb. units) compared to baseline (p<0.05; Two Way Repeated Measures ANOVA/Bonferroni t-test). The lowest dosage of 0.001 mg/kg b. w. betahistine or NaCl 0.9% had the same effect as placebo. Nonlinear regression revealed that there was a sigmoid correlation between increase in blood flow and dosages. Conclusions Betahistine has a dose-dependent effect on the increase of blood flow in cochlear capillaries. The effects of the dosage range of betahistine on cochlear microcirculation corresponded well to clinically used single dosages to treat Menière’s disease. Our data suggest that the improved effects of higher doses of betahistine in the treatment of Menière’s disease might be due to a corresponding increase of cochlear blood flow. PMID:22745706
Uysal, İsmail Önder; Kaya, Ali; Güven, Ahmet Sami; Altuntaş, Emine Elif; Müderris, Suphi
2011-06-01
The aim of this study was to investigate cochlear involvement in child patients with Crimean-Congo hemorrhagic fever (CCHF) disease. Twenty-eight CCHF disease patients (56 ears) and 26 sex- and age-matched healthy control subjects (52 ears) were included in the study. Pure-tone audiometry at frequencies 0.25, 0.5, 1, 2, 4, and 6 kHz, immittance measures including tympanometry and acoustic reflex testing, and transient evoked otoacoustic emission (TEOAE) testing were performed in the patients and controls. The proportion with a result of 'fail' for the TEOAE test in the CCHF patients was not statistically significant from the control group (p>0.05). CCHF disease does not impair cochlear function in children. The clinical course of CCHF among children seems to be milder than in adults. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Li, Xu; Mao, Xiao-Bo; Hei, Ren-Yi; Zhang, Zhi-Bin; Wen, Li-Ting; Zhang, Peng-Zhi; Qiu, Jian-Hua; Qiao, Li
2011-01-01
A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL). The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2)S) has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2)S in cochlear blood flow regulation and noise protection. The gene and protein expression of the H(2)S synthetase cystathionine-γ-lyase (CSE) in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP), NaHS or DL-propargylglycine (PPG) were locally administered. Local sodium hydrosulfide (NaHS) significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR), cochlear scanning electron microscope (SEM) and outer hair cell (OHC) count. The highest percentage of OHC loss occurred in the PPG group. Our results suggest that H(2)S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.
Cochlear Patency After Transmastoid Labyrinthectomy for Ménière's Syndrome.
Sargent, Eric W; Liao, Eric; Gonda, Roger L
2016-08-01
Labyrinthectomy is considered the "gold standard" in the treatment of intractable vertigo attacks because of Ménière's Disease (MD) but sacrifices all residual hearing. Interest in auditory rehabilitation has lead to cochlear implantation in some patients. Concern remains that the cochlear lumen may fill with tissue or bone after surgery. This study sought to determine the incidence of obliteration of the cochlea after transmastoid labyrinthectomy. Retrospective observational study. Tertiary referral center. Eighteen patients with intractable vertigo from MD who underwent surgery. Transmastoid labyrinthectomy between 2008 and 2013. Cochleas were imaged with unenhanced, heavily T2-weighted magnetic resonance imaging (MRI). Presence of symmetrical cochlear fluid signals on MRI. There was no loss of fluid signal in the cochleas of operated ear compared with the contralateral, unoperated ear in any subject an average of 3 years (standard deviation [SD]: 1.2) after surgery. Five of 18 patients had the vestibule blocked with bone wax at the time of surgery. Blocking the vestibule with bone wax did not change the cochlear fluid signal. The risk of cochlear obstruction after labyrinthectomy for MD is very low. The significance of this finding is that patients with MD who undergo labyrinthectomy will likely remain candidates for cochlear implantation in the labyrinthectomized ear long after surgery if this becomes needed. Immediate cochlear implantation or placement of a cochlear lumen keeper during labyrinthectomy for MD is probably not necessary.
Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.
Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr
2017-01-01
Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.
Multichannel cochlear implantation in the scala vestibuli.
Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas
2006-08-01
Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.
Innovative pharmaceutical approaches for the management of inner ear disorders.
Musazzi, Umberto M; Franzé, Silvia; Cilurzo, Francesco
2018-04-01
The sense of hearing is essential for permitting human beings to interact with the environment, and its dysfunctions can strongly impact on the quality of life. In this context, the cochlea plays a fundamental role in the transformation of the airborne sound waves into electrical signals, which can be processed by the brain. However, several diseases and external stimuli (e.g., noise, drugs) can damage the sensorineural structures of cochlea, inducing progressive hearing dysfunctions until deafness. In clinical practice, the current pharmacological approaches to treat cochlear diseases are based on the almost exclusive use of systemic steroids. In the last decades, the efficacy of novel therapeutic molecules has been proven, taking advantage from a better comprehension of the pathological mechanisms underlying many cochlear diseases. In addition, the feasibility of intratympanic administration of drugs also permitted to overcome the pharmacokinetic limitations of the systemic drug administration, opening new frontiers in drug delivery to cochlea. Several innovative drug delivery systems, such as in situ gelling systems or nanocarriers, were designed, and their efficacy has been proven in vitro and in vivo in cochlear models. The current review aims to describe the art of state in the cochlear drug delivery, highlighting lights and shadows and discussing the most critical aspects still pending in the field.
Lane, John I; Witte, Robert J; Driscoll, Colin L W; Shallop, Jon K; Beatty, Charles W; Primak, Andrew N
2007-08-01
To use the improved resolution available with 64-slice multidetector computed tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal turn. Sixty-four-slice MDCT examinations of the temporal bones were retrospectively reviewed in 17 patients. Twenty-three implants were evaluated. Tertiary referral facility. All patients with previous cochlear implantation evaluated at our center between January 2004 and March 2006 were offered a computed tomographic examination as part of the study. In addition, preoperative computed tomographic examinations in patients being evaluated for a second bilateral device were included. Sixty-four-slice MDCT examination of the temporal bones. Localization of the electrode array within the basal turn from multiplanar reconstructions of the cochlea. Twenty-three implants were imaged in 17 patients. We were able to localize the electrode array within the scala tympani within the basal turn in 10 implants. In 3 implants, the electrode array was localized to the scala vestibuli. Migration of the electrode array from scala tympani to scala vestibuli was observed in three implants. Of the 7 implants in which localization of the electrode array was indeterminate, all had disease entities that obscured the definition of the normal cochlear anatomy. Sixty-four-slice MDCT with multiplanar reconstructions of the postoperative cochlea after cochlear implantation allows for accurate localization of the electrode array within the basal turn where normal cochlear anatomy is not obscured by the underlying disease process. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes.
Piribedil affects dopamine turnover in cochleas stimulated by white noise.
Gil-Loyzaga, P; Vicente-Torres, M A; Fernández-Mateos, P; Arce, A; Esquifino, A
1994-09-01
The presence of dopamine (DA) within the cochlea has been previously reported, indicating that its turnover increases under noise stimulation. In the present report, piribedil, a dopaminergic D2 agonist, was used in order to provide evidence of the activity of D2 receptors in the turnover of DA under noise stimulation. Long-Evans rats were intraperitoneally injected with distilled water or with a solution of piribedil one hour previously to either noise or silence exposure. Noise stimulation was performed in an anechoic chamber at 70, 90 or 110 dB SPL for one hour. The animals were then sacrificed and the cochlear contents of DA and its metabolites dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) were quantified by HPLC with electrochemical detection. The administration of piribedil to animals kept in silence did not modify the cochlear DA, DOPAC and HVA content. Noise stimulation resulted in a decrease of the cochlear DA content and an increase of the cochlear DOPAC and HVA contents in vehicle treated animals. The administration of piribedil resulted in a blockade of this noise induced cochlear DA turnover. These results suggest that piribedil stimulates cochlear D2 receptors controlling the cochlear DA release. Piribedil action on D2 receptors could explain the improvement observed in some cochleo-vestibular diseases signs after piribedil treatment.
Wang, Jenny R; Yuen, Heng W; Shipp, David B; Stewart, Suzanne; Lin, Vincent Y W; Chen, Joseph M; Nedzelski, Julian M
2010-12-01
Evaluate the characteristics and outcomes of patients with autoimmune inner ear disease (AIED) who have undergone cochlear implantation (CI) and compare post-CI performance in AIED to matched controls. Retrospective case control study. Study cohort was comprised of 25 adult implantees (AIED [n = 18], Cogan syndrome [n = 7]). The AIED group was defined by rapidly progressive bilateral sensorineural hearing loss leading to unusable hearing within weeks to months. Patients with Cogan syndrome, the archetypal inner ear autoimmune disease, were also examined and used for within-cohort comparison. Clinical and operative records were reviewed. Post-CI performance was assessed using open-set sentence tests. Age- and sex-matched individuals deafened by other postlingual causes were used as controls. Of 25 patients, 24 had uneventful, full electrode insertions. One AIED patient had partial insertion due to cochlear ossification and did not achieve open-set speech perception post-CI. Mean open-set sentence scores for study patients with uneventful insertions were 92.8%, 97.3%, and 96.4% at 6 months, 1 year, and ≥ 2 years, respectively. Compared to matched controls, patients deafened by autoimmune causes had significantly higher post-CI performance at all postoperative test intervals (P < .05). There was no significant difference in postimplantation performance between Cogan syndrome and AIED patients. To our knowledge this was the largest study of cochlear implantation in AIED and Cogan syndrome patients. In our experience, both groups generally attained high levels of post-CI speech perception and performed above average. Cochlear ossification affecting implantation in Cogan syndrome patients was not observed in our series, contrary to some reports.
Cochlear implant challenges encountered in tuberculous otitis media.
Chen, Cheng-Fang; Liu, Zhao-Hui; Xie, Jing; Ma, Xiao-Bo; Li, Yi; Gong, Shu-Sheng
2012-05-01
Tuberculous otitis media (TOM) is rare in ENT department, and is frequently misdiagnosed as otitis media. Thus early systemic treatment is very important for TOM. We reported a case report with TOM to highlight development of the disease and difficulties in clinical treatment in late stage of TOM. Implantation of ossified and eroded cochlea poses many unique challenges to both the surgeon and programming team. With thorough preparation and complete knowledge about characters of specific issues, implantation would be performed successfully, and patients with ossified cochlear could benefit from cochlear implantation. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.
Hear ye? Hear ye! Successful auditory aging.
Gates, G A; Rees, T S
1997-01-01
Age-related hearing loss (presbycusis) is a multifactorial process that affects nearly all people in their senior years. Most cases are due to a loss of cochlear hair cell function and are well mediated by communication courtesy and modern amplification technology. Severe hearing loss is generally due to cochlear problems or age-related diseases and may require speech reading, assistive listening devices, and cochlear implants, depending on the degree of loss. Presbycusis may seriously impair communication and contribute to isolation, depression, and possibly dementia. Accurate diagnosis and prompt remediation are widely available but are frequently underused. Geriatric health care and well-being is enhanced by the detection and remediation of communication disorders. PMID:9348755
Eftekharian, Ali; Mahani, Mozhgan Hosseinerezai
2015-09-01
To share our experience in cochlear implanted patients with Jervell and Lange-Nielsen syndrome (JLNS), to review the literature results and to disclose precautions which have to be taken dealing with these patients. Electrocardiograms (ECG) of 503 children with congenital bilateral profound hearing loss which were cochlear implanted in cochlear implant center of a tertiary hospital were evaluated for long QT syndrome. Clinical reports of the patients with JLNS were evaluated and a review of literature performed. The prevalence of disease was 0.79% (four cases) in our center which is in the range of literature reports (0-2.6%). None of our patients had a history of syncopal attack. Two patients (50%) were born from parents with consanguineous marriage. Considering all precautions their cochlear implant surgeries were done uneventfully. A review of the literature has identified sixteen reports on cochlear implantation in a total of 38 children with JLNS. Similar to our cases none of the authors reported cardiac events during device switch-on. Nine available reports about the outcome of cochlear implantation in these patients indicated good auditory outcome. It is recommended that all congenitally deaf patients have an ECG taken as a part of the evaluation. As auditory stimuli is reported to be a specific trigger, it is prudent to activate the processor with continuous heart monitoring even though there is no reported cardiac event during device switch-on. Cochlear implantation can be performed relatively safely in these patients if necessary precautions have been taken appropriately and their auditory outcome is good. Triggers of the cardiac events should be avoided throughout their life. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Translabyrinthine vestibular neurectomy and simultaneous cochlear implant for Ménière's disease.
Canzi, Pietro; Manfrin, Marco; Perotti, Marco; Aprile, Federico; Quaglieri, Silvia; Rebecchi, Elisabetta; Locatelli, Giulia; Benazzo, Marco
2017-01-01
Surgical management of Ménière's disease (MD) is recommended in case of medical and intratympanic treatment failures. Translabyrinthine vestibular nerve section has been considered the gold standard for denervation procedures in order to control vertigo attacks, although at the cost of sacrificing residual hearing. To the best of our knowledge, no work has been published with regard to a group of patients submitted to translabyrinthine vestibular neurectomy and simultaneous cochlear implant for MD. The aim of the present study was to assess the effectiveness of translabyrinthine vestibular nerve section and simultaneous cochlear implant in a prospective study. All adult patients (over 18 years of age) with a diagnosis of intractable unilateral definite MD and useless residual hearing function were enrolled after medical and intratympanic treatment failures. Pre- and postoperative otoneurological evaluation concerned: frequency of vertigo attacks, head impulse test and caloric testing, pure tone average and speech perception audiometry in quiet conditions, tinnitus handicap inventory test, functional level scale and rate of vertigo control, dizziness handicap inventory test, and MD patient-oriented severity index. At least 6 months of follow-up were needed to be enrolled in the study. Four patients were included in the study. Translabyrinthine vestibular nerve section and simultaneous cochlear implant seemed to considerably improve the disabling effects of MD, achieving a good control of vestibular symptoms (mean pre/postoperative vertigo attacks per month: 16.5/0), resolving hearing loss (mean pre/postoperative pure tone average in the affected ear: 86.2/32.5 dB), improving the tinnitus (mean pre/postoperative tinnitus handicap inventory test: 77.2/6), and finally increasing the overall quality-of-life parameters. In our preliminary report, translabyrinthine vestibular nerve section and simultaneous cochlear implant showed encouraging results in order to definitively control both vestibular and cochlear symptoms during the same therapeutic procedure.
Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.
Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J
2012-08-01
Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.
Cochlear dysfunction in hyperuricemia: otoacoustic emission analysis.
Hamed, Sherifa A; El-Attar, Amal M
2010-01-01
The objective of this study is to provide evidence that primary hyperuricemia is associated with cochlear dysfunction as other metabolic diseases that interfere with cell metabolism. Cochlear function was evaluated in 25 subjects with asymptomatic hyperuricemia using routine diagnostic audiometry along with transient evoked and distortion product otoacoustic emissions (TEOAE and DPOAE, respectively). To support the notion that vascular compromise was a significant underlying factor for such cochlear dysfunction, we assessed vascular anatomical and functional states through measuring the common carotid artery intima-media thickness and flow velocity of the basal intracranial vessels. Compared with control subjects, reduced response levels of TEOAEs (P < .01) and amplitudes of DPOAEs (P < .001) were detected at higher frequencies. The reduced DPOAE levels at 5 kHz and TEOAEs at 4 kHz correlated significantly with uric acid (P < .05; P < .01), patients' age (P < .06; P < .05), duration since diagnosis of hyperuricemia (P < .05; P < .001), common carotid artery intima-media thickness (P < .05), mean flow velocities of middle cerebral arteries (P < .05), and vertebral arteries (P < .01). Multivariate analysis showed that the abnormalities at higher frequencies were significantly correlated with the duration and degree of hyperuricemia. These data suggest that subclinical changes in cochlear function are associated with hyperuricemia. They support the usefulness of otoacoustic emissions in early detection of cochlear dysfunction. It is possible that hyperuricemia could be accompanied by increased stiffness and/or compromise of blood supply of the outer hair cells, which will impair their electromotile response. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Ciuman, Raphael R
2009-01-01
There exist 3 communication routes between the intracranial space and the inner ear, the vestibular aqueduct, the cochlear aqueduct, and the internal auditory canal. They possess a key role in inner ear pressure regulation and fluid homeostasis and are related to inner ear diseases. Relevant literature was reviewed, and the current knowledge of the anatomy, physiologic importance, and relations to inner ear diseases were described. Pathologic communication routes such as semicircular canal dehiscence syndrome were highlighted as well. Abnormalities in all 3 communication routes may predispose or be the cause of distinct inner ear pathologic condition and involved in other cochlear and vestibular syndromes, in which their role is not completely clear. The increasing knowledge of the underlying mechanisms encourages promising approaches for possible intervention in the future.
Derks, Laura S M; Wegner, Inge; Smit, Adriana L; Thomeer, Hans G X M; Topsakal, Vedat; Grolman, Wilko
2016-01-01
Introduction Cochlear implantation is an increasingly common procedure in the treatment of severe to profound sensorineural hearing loss (SNHL) in children and adults. It is often performed as a day-case procedure. The major drive towards day-case surgery has been from a logistical, economical and societal perspective, but we also speculate that the patient's quality of life (QoL) is at least equal to inpatient surgery if not increased as a result of rapid discharge and rehabilitation. Even though cochlear implantation seems well suited to a day-case approach and this even seems to be common practice in some countries, evidence is scarce and of low quality to guide us towards the preferred treatment option. Methods and analysis A single-centre, non-blinded, randomised, controlled trial was designed to (primarily) investigate the effect on general QoL of day-case cochlear implantation compared to inpatient cochlear implantation and (secondarily) the effect of both methods on (subjective) hearing improvement, disease-specific QoL, tinnitus, vertigo and cost-effectiveness. 30 adult patients with severe to profound bilateral postlingual SNHL who are eligible for unilateral cochlear implantation will be randomly assigned to either the day-case or inpatient treatment group. The outcome measures will be assessed using auditory evaluations, questionnaires (preoperatively, at 1-week, 3-week, 3-month and 1-year follow-up) and costs diaries (weekly during the first month postoperatively, after which once in a month until 1-year follow-up). Preoperative and postoperative outcomes will be compared. The difference in costs and benefit will be represented using the incremental cost utility/effectiveness ratio. The analyses will be carried out on an intention-to-treat basis. Ethics and dissemination This research protocol was approved by the Institutional Review Board of the UMC Utrecht (NL45590.041.13; V.5, November 2015). The trial results will be disseminated through peer-reviewed medical journals and presented at scientific conferences. Trial registration number NTR4464; Pre-results. PMID:27697874
Evaluation of cochlear involvement by distortion product otoacoustic emission in Behçet's disease.
Dagli, Muharrem; Eryilmaz, Adil; Tanrikulu, Salih; Aydin, Acar; Gonul, Muzeyyen; Gul, Ulker; Gocer, Celil
2008-09-01
The aim of this study was to investigate cochlear involvement in patients with Behçet's disease. Twenty-six Behçet's disease patients (52 ears) and 24 sex and age-matched healthy control subjects (48 ears) were included in the study. Pure-tone audiometry at frequencies 250, 500, 1000, 2000, 4000, 6000 Hz, immittance measures including tympanometry and acoustic reflex testing and DPOAE (distortion product otoacoustic emission) testing were performed in the patients and controls. A sensorineural hearing loss was found in eight patients (30.7%) as it was bilateral in five and unilateral in three patients. Although no typical audiometric configuration was found, one patient had a flat type audiogram, and the others had a high frequency hearing loss. The DPOAE responses of the patients and controls were significantly different in all frequencies (p<0.05). These results indicate that cochlea is affected by damage of outer hair cells in Behçet's disease.
... heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or are on dialysis (you ... Diagnose abnormal growths in the chest Evaluate blood flow Show lymph nodes and blood vessels Show the ...
Hepatocyte nuclear factor-4 alpha in noise-induced cochlear neuropathy.
Groth, Jane Bjerg; Kao, Shyan-Yuan; Briët, Martijn C; Stankovic, Konstantina M
2016-12-01
Noise-induced hearing loss (NIHL) is a problem of profound clinical significance and growing magnitude. Alarmingly, even moderate noise levels, previously assumed to cause only temporary shifts in auditory thresholds ("temporary" NIHL), are now known to cause cochlear synaptopathy and subsequent neuropathy. To uncover molecular mechanisms of this neuropathy, a network analysis of genes reported to have significantly altered expression after temporary threshold shift-inducing noise exposure was performed. The transcription factor Hepatocyte Nuclear Factor-4 alpha (HNF4α), which had not previously been studied in the context of cochlear response to noise, was identified as a hub of a top-ranking network. Hnf4α expression and localization using quantitative RT-PCR and in situ hybridization, respectively, were described in adolescent and adult mice exposed to neuropathic noise levels in adolescence. Isoforms α3 and α12 in the cochlea were also identified. At every age examined, Hnf4α mRNA expression in the cochlear apex was similar to expression in the base. Hnf4α expression was evident in select cochlear cells, including spiral ganglion neurons (SGNs) and hair cells, and was significantly upregulated from 6 to 70 weeks of age, especially in SGNs. This age-related Hnf4α upregulation was inhibited by neuropathic noise exposure in adolescence. Hnf4α silencing with shRNA transfection into auditory neuroblast cells (VOT-33) reduced cell viability, as measured with the MTT assay, suggesting that Hnf4α may be involved in SGN survival. Our results motivate future studies of HNF4α in cochlear pathophysiology, especially because HNF4α mutations and polymorphisms are associated with human diseases that may include hearing loss. © 2016 Wiley Periodicals, Inc. Develop Neurobiol 76: 1374-1386, 2016. © 2016 Wiley Periodicals, Inc.
The effect of topically administered latanoprost on the cochlear blood flow and hearing.
Jang, Chul Ho; Cho, Yong Beom; Choi, Cheol Hee; Um, Jae-Young; Wang, Pa-Chun; Pak, Sok Cheon
2013-06-01
The application of intratympanic latanoprost (PGF2α analog) has been recently used to alleviate vertigo, disequilibrium and to improve hearing in Meniere's disease patients. However, there is no known report on the effect of topically applied latanoprost on hearing and cochlear hemodynamic parameters including cochlear blood flow (CBF) and vascular conductance. Our goal was to assess the influence of topically applied latanoprost on cochlear blood flow (CBF) and hearing. Twenty male Sprague-Dawley rats were randomly divided into the group A, 50 μl of latanoprost (1 ml containing 50 μg, n=10) and group B, 100 μl (1 ml containing 50 μg, n=10). Topical application of latanoprost was performed at the right side, and the left side was applied with phosphate buffered saline (PBS) as a negative control. Five rats at each group were used to measure cochlear blood flow (CBF). And the others at each group were used for hearing test by auditory brainstem response (ABR). After physiological examination, bullas were extracted. The changes of cochlear hair cells were observed by performing the field emission-scanning electron microscopy (FE-SEM). The CBF of both groups was found to be decreased compared to the PBS applied left side. Significant decrement of CBF was observed in group B compared to the group A. Significant elevation of hearing threshold at high frequencies was observed in both groups compared to the PBS applied group. However, inner and outer hair cells were intact. Topically administered latanoprost decreased the CBF and impaired hearing. Based on our findings, additional studies are required to evaluate the side effects of intratympanic latanoprost before its use in clinical practice. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
... aneurysm clips Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not ... test may be used to look at: Blood flow in the abdomen Blood vessels in the abdomen ...
... heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not ... that remains after surgery or chemotherapy Show blood flow through the breast area Guide a biopsy (not ...
Racemic alkaloids from the fungus Ganoderma cochlear.
Wang, Xin-Long; Dou, Man; Luo, Qi; Cheng, Li-Zhi; Yan, Yong-Ming; Li, Rong-Tao; Cheng, Yong-Xian
2017-01-01
Seven pairs of new alkaloid enantiomers, ganocochlearines C-I (1, 3-8), and three pairs of known alkaloids were isolated from the fruiting bodies of Ganoderma cochlear. The chemical structures of new compounds were elucidated on the basis of 1D and 2D NMR data. The absolute configurations of compounds 1, 3-10 were assigned by ECD calculations. Biological activities of these isolates against renal fibrosis were accessed in rat normal or diseased renal interstitial fibroblast cells. Importantly, the plausible biosynthetic pathway for this class of alkaloids was originally proposed. Copyright © 2016 Elsevier B.V. All rights reserved.
... the test, tell your provider if you have: Artificial heart valves Brain aneurysm clips Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not ... artificial joints Vascular stents Worked with sheet metal in ...
Generation of induced neurons by direct reprogramming in the mammalian cochlea.
Nishimura, K; Weichert, R M; Liu, W; Davis, R L; Dabdoub, A
2014-09-05
Primary auditory neurons (ANs) in the mammalian cochlea play a critical role in hearing as they transmit auditory information in the form of electrical signals from mechanosensory cochlear hair cells in the inner ear to the brainstem. Their progressive degeneration is associated with disease conditions, excessive noise exposure and aging. Replacement of ANs, which lack the ability to regenerate spontaneously, would have a significant impact on research and advancement in cochlear implants in addition to the amelioration of hearing impairment. The aim of this study was to induce a neuronal phenotype in endogenous non-neural cells in the cochlea, which is the essential organ of hearing. Overexpression of a neurogenic basic helix-loop-helix transcription factor, Ascl1, in the cochlear non-sensory epithelial cells induced neurons at high efficiency at embryonic, postnatal and juvenile stages. Moreover, induced neurons showed typical properties of neuron morphology, gene expression and electrophysiology. Our data indicate that Ascl1 alone or Ascl1 and NeuroD1 is sufficient to reprogram cochlear non-sensory epithelial cells into functional neurons. Generation of neurons from non-neural cells in the cochlea is an important step for the regeneration of ANs in the mature mammalian cochlea. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Cochlear Implant Using Neural Prosthetics
NASA Astrophysics Data System (ADS)
Gupta, Shweta; Singh, Shashi kumar; Dubey, Pratik Kumar
2012-10-01
This research is based on neural prosthetic device. The oldest and most widely used of these electrical, and often computerized, devices is the cochlear implant, which has provided hearing to thousands of congenitally deaf people in this country. Recently, the use of the cochlear implant is expanding to the elderly, who frequently suffer major hearing loss. More cutting edge are artificial retinas, which are helping dozens of blind people see, and ìsmartî artificial arms and legs that amputees can maneuver by thoughts alone, and that feel more like real limbs.Research, which curiosity led to explore frog legs dancing during thunderstorms, a snail shapedorgan in the inner ear, and how various eye cells react to light, have fostered an understanding of how to ìtalkî to the nervous system. That understanding combined with the miniaturization of electronics and enhanced computer processing has enabled prosthetic devices that often can bridge the gap in nerve signaling that is caused by disease or injury.
Anaesthesia Management in a Patient with Waardenburg Syndrome and Review of the Literature.
Peker, Kevser; Ergil, Julide; Öztürk, İbrahim
2015-10-01
Waardenburg syndrome is a rare autosomal dominant disease that may cause hearing loss, pigmentary abnormalities, neurocristopathy and partial albinism. Incidence is estimated as 2%-3% among the cases of congenital deafness and 1/42,000 of the general population. Children with Waardenburg syndrome usually require anaesthesia for the cochlear implant operation in early age. The features of the syndrome that may bear importance for anaesthetic management are laryngomalacia, multiple muscle contractures, limited neck movements, cyanotic cardiopathy and electrolyte imbalance. Patients with Waardenburg syndrome stand for difficult airway. We aimed to report anaesthetic management of a child with Waardenburg syndrome who underwent surgery for cochlear implantation.
New Criteria of Indication and Selection of Patients to Cochlear Implant
Sampaio, André L. L.; Araújo, Mercêdes F. S.; Oliveira, Carlos A. C. P.
2011-01-01
Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant. PMID:22013448
... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...
... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...
... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...
Hirt, B; Penkova, Z H; Eckhard, A; Liu, W; Rask-Andersen, H; Müller, M; Löwenheim, H
2010-07-28
Aquaporins are membrane water channel proteins that have also been identified in the cochlea. Auditory function critically depends on the homeostasis of the cochlear fluids perilymph and endolymph. In particular, the ion and water regulation of the endolymph is essential for sensory transduction. Within the cochlear duct the lateral wall epithelium has been proposed to secrete endolymph by an aquaporin-mediated flow of water across its epithelial tight junction barrier. This study identifies interspecies differences in the cellular distribution of aquaporin 5 (AQP5) in the cochlear lateral wall of mice, rats, gerbils and guinea pigs. In addition the cellular expression pattern of AQP5 is described in the human cochlea. Developmental changes in rats demonstrate longitudinal and radial gradients along the cochlear duct. During early postnatal development a pancochlear expression is detected. However a regression to the apical quadrant and limitation to outer sulcus cells (OSCs) is observed in the adult. This developmental loss of AQP5 expression in the basal cochlear segments coincides with a morphological loss of contact between OSCs and the endolymph. At the subcellular level, AQP5 exhibits polarized expression in the apical plasma membrane of the OSCs. Complementary, the basolateral membrane in the root processes of the OSCs exhibits AQP4 expression. This differential localization of AQP5 and AQP4 in the apical and basolateral membranes of the same epithelial cell type suggests a direct aquaporin-mediated transcellular water shunt between the perilymph and endolymph in the OSCs of the cochlear lateral wall. In the human cochlea these findings may have pathophysiological implications attributed to a dysfunctional water regulation by AQP5 such as endolymphatic hydrops (i.e. in Meniere's disease) or sensorineural hearing loss (i.e. in Sjögren's syndrome). Copyright (c) 2010 IBRO. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Clark, Catherine; Scott, Larry
This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…
Colletti, Vittorio; Mandalà, Marco; Manganotti, Paolo; Ramat, Stefano; Sacchetto, Luca; Colletti, Liliana
2011-07-01
The rapid spread of devices generating electromagnetic fields (EMF) has raised concerns as to the possible effects of this technology on humans. The auditory system is the neural organ most frequently and directly exposed to electromagnetic activity owing to the daily use of mobile phones. In recent publications, a possible correlation between mobile phone usage and central nervous system tumours has been detected. Very recently a deterioration in otoacoustic emissions and in the auditory middle latency responses after intensive and long-term magnetic field exposure in humans has been demonstrated. To determine with objective observations if exposure to mobile phone EMF affects acoustically evoked cochlear nerve compound action potentials, seven patients suffering from Ménière's disease and undergoing retrosigmoid vestibular neurectomy were exposed to the effects of mobile phone placed over the craniotomy for 5 min. All patients showed a substantial decrease in amplitude and a significant increase in latency of cochlear nerve compound action potentials during the 5 min of exposure to EMF. These changes lasted for a period of around 5 min after exposure. The possibility that EMF can produce relatively long-lasting effects on cochlear nerve conduction is discussed and analysed in light of contrasting previous literature obtained under non-surgical conditions. Limitations of this novel approach, including the effects of the anaesthetics, craniotomy and surgical procedure, are presented in detail.
Anaesthesia Management in a Patient with Waardenburg Syndrome and Review of the Literature
Peker, Kevser; Ergil, Julide; Öztürk, İbrahim
2015-01-01
Waardenburg syndrome is a rare autosomal dominant disease that may cause hearing loss, pigmentary abnormalities, neurocristopathy and partial albinism. Incidence is estimated as 2%–3% among the cases of congenital deafness and 1/42,000 of the general population. Children with Waardenburg syndrome usually require anaesthesia for the cochlear implant operation in early age. The features of the syndrome that may bear importance for anaesthetic management are laryngomalacia, multiple muscle contractures, limited neck movements, cyanotic cardiopathy and electrolyte imbalance. Patients with Waardenburg syndrome stand for difficult airway. We aimed to report anaesthetic management of a child with Waardenburg syndrome who underwent surgery for cochlear implantation. PMID:27366529
[Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].
Zhang, Daoxcing; Zhang, Yankun
2006-02-01
Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.
What Does Music Sound Like for a Cochlear Implant User?
Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J
2017-09-01
Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.
Progress in Cochlear Physiology after Békésy
Guinan, John J.; Salt, Alec; Cheatham, Mary Ann
2012-01-01
In the fifty years since Békésy was awarded the Nobel Prize, cochlear physiology has blossomed. Many topics that are now current are things Békésy could not have imagined. In this review we start by describing progress in understanding the origin of cochlear gross potentials, particularly the cochlear microphonic, an area in which Békésy had extensive experience. We then review progress in areas of cochlear physiology that were mostly unknown to Békésy, including: (1) stereocilia mechano-electrical transduction, force production, and response amplification, (2) outer hair cell (OHC) somatic motility and its molecular basis in prestin, (3) cochlear amplification and related micromechanics, including the evidence that prestin is the main motor for cochlear amplification, (4) the influence of the tectorial membrane, (5) cochlear micromechanics and the mechanical drives to inner hair cell stereocilia, (6) otoacoustic emissions, and (7) olivocochlear efferents and their influence on cochlear physiology. We then return to a subject that Békésy knew well: cochlear fluids and standing currents, as well as our present understanding of energy dependence on the lateral wall of the cochlea. Finally, we touch on cochlear pathologies including noise damage and aging, with an emphasis on where the field might go in the future. PMID:22633944
Effect of cochlear nerve electrocautery on the adult cochlear nucleus.
Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A
2015-04-01
Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.
Hsiao, Feilin; Gfeller, Kate
2013-01-01
This review of literature presents a systematic analysis of the capabilities and limitations of cochlear implant recipients regarding music perception. Specifically, it a) analyzes individual components of music (e.g., rhythm, timbre, and pitch) as they interface with the technical characteristics of cochlear implants and the perceptual abilities of cochlear implant recipients; and b) describes accommodations for music instruction that support successful participation of children with cochlear implants. This article consolidates research studies from various disciplines (audiology, hearing science, speech-language pathology, cochlear implants, and music therapy) to provide practical recommendations for educators in fostering the musical growth of children with cochlear implants. PMID:23469365
Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.
Hassanzadeh, S
2012-10-01
This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.
Cochlear implant revision surgeries in children.
Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo
2018-02-16
The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Parental expectations and outcomes of pediatric cochlear implantation.
Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D
2009-10-01
Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.
Lichtenhan, J T; Hartsock, J; Dornhoffer, J R; Donovan, K M; Salt, A N
2016-11-01
Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. Copyright © 2016 Elsevier B.V. All rights reserved.
Lichtenhan, JT; Hartsock, J; Dornhoffer, JR; Donovan, KM; Salt, AN
2016-01-01
Background Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. New method Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Results Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Conclusions Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. PMID:27506463
Serotonin projection patterns to the cochlear nucleus.
Thompson, A M; Thompson, G C
2001-07-13
The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the dorsal cochlear nucleus, we concluded that the serotoninergic projection pattern to the cochlear nucleus is divergent and non-specific. Double-labeled fiber segments were also present, but sparse, in the superior olive, localized mainly in periolivary regions; this indicated that the divergence of dorsal and median raphe neurons that extends throughout regions of the cochlear nucleus also extended well beyond the cochlear nucleus to include at least the superior olivary complex as well.
Cochlear implantation in patients with bilateral cochlear trauma.
Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar
2010-01-01
Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.
Phase contrast imaging of cochlear soft tissue.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, S.; Hwang, M.; Rau, C.
A noninvasive technique to image soft tissue could expedite diagnosis and disease management in the auditory system. We propose inline phase contrast imaging with hard X-rays as a novel method that overcomes the limitations of conventional absorption radiography for imaging soft tissue. In this study, phase contrast imaging of mouse cochleae was performed at the Argonne National Laboratory Advanced Photon Source. The phase contrast tomographic reconstructions show soft tissue structures of the cochlea, including the inner pillar cells, the inner spiral sulcus, the tectorial membrane, the basilar membrane, and the Reissner's membrane. The results suggest that phase contrast X-ray imagingmore » and tomographic techniques hold promise to noninvasively image cochlear structures at an unprecedented cellular level.« less
In vivo observation of dynamic perilymph formation using 4.7 T MRI with gadolinium as a tracer.
Zou, Jing; Pyykkö, Ilmari; Counter, S Allen; Klason, Tomas; Bretlau, Poul; Bjelke, Börje
2003-10-01
To investigate the pharmacokinetics of gadolinium in the perilymphatic fluid spaces of the cochlea in vivo using high-resolution MRI to obtain information concerning perilymph formation. A Bruker Biospec Avance 47/40 experimental MRI system with a magnetic field strength of 4.7 T was used. Anesthetized pigmented guinea pigs were injected with the contrast agent Gd-diethylenetriaminepentaacetic acid-bismethylamide and placed in the magnet. The signal intensity of Gd in the tissues was used as a biomarker for dynamic changes in the perilymphatic fluid. The most rapid uptake of Gd in the perilymphatic fluid spaces occurred in the lower part of the modiolus, followed by the second turn of the scala tympani. Within the scala tympani, the distribution of Gd in the basal turn was significantly lower than that in the other turns. Destruction of the cochlear aqueduct was followed by an increase in Gd uptake in the perilymph instead of a reduction. These findings offer further evidence that the pervasive perilymphatic fluid derives from the cochlear blood supply via the cochlear glomeruli, which are in close proximity to the scala tympani within the modiolus, and the capillary in the spiral ligament. Cerebrospinal fluid communicates with perilymph via the cochlear aqueduct but is not the main source of perilymph. These findings are of relevance to the treatment of inner ear diseases, as well as to our understanding of the flow and source of perilymphatic fluid.
The role of intracochlear drug delivery devices in the management of inner ear disease.
Ayoob, Andrew M; Borenstein, Jeffrey T
2015-03-01
Diseases of the inner ear include those of the auditory and vestibular systems, and frequently result in disabling hearing loss or vertigo. Despite a rapidly expanding pipeline of potential cochlear therapeutics, the inner ear remains a challenging organ for targeted drug delivery, and new technologies are required to deliver these therapies in a safe and efficacious manner. In addition to traditional approaches for direct inner ear drug delivery, novel microfluidics-based systems are under development, promising improved control over pharmacokinetics over longer periods of delivery, ultimately with application towards hair cell regeneration in humans. Advances in the development of intracochlear drug delivery systems are reviewed, including passive systems, active microfluidic technologies and cochlear prosthesis-mediated delivery. This article provides a description of novel delivery systems and their potential future clinical applications in treating inner ear disease. Recent progresses in microfluidics and miniaturization technologies are enabling the development of wearable and ultimately implantable drug delivery microsystems. Progress in this field is being spurred by the convergence of advances in molecular biology, microfluidic flow control systems and models for drug transport in the inner ear. These advances will herald a new generation of devices, with near-term applications in preclinical models, and ultimately with human clinical use for a range of diseases of the inner ear.
Cochlear implant in Hong Kong Cantonese.
Tang, S O; Luk, W S; Lau, C C; So, K W; Wong, C M; Yiu, M L; Kwok, C L
1990-11-01
Cochlear implant surgery was performed in four Cantonese-speaking postlingually deaf Chinese adults, using the House/3M single channel device. This article outlines the methodology, including preoperative assessment and postoperative rehabilitation; and explains the necessary modifications in speech and audiologic work-up in Cantonese-speaking patients. Salient features of Cantonese phonetics, especially its tonal characteristics, are described. The findings of the study are presented. The results of the cochlear implant would suggest a performance superior to that of the hearing aid. Furthermore, the cochlear implant is able to detect tonal cues. This quality of the cochlear implant may prove to be a valuable asset to a tonal language-speaking cochlear implantee.
Dai, Min; Nuttall, Alfred; Yang, Yue; Shi, Xiaorui
2009-08-01
Pericytes, mural cells located on microvessels, are considered to play an important role in the formation of the vasculature and the regulation of local blood flow in some organs. Little is known about the physiology of cochlear pericytes. In order to investigate the function of cochlear pericytes, we developed a method to visualize cochlear pericytes using diaminofluorescein-2 diacetate (DAF-2DA) and intravital fluorescence microscopy. This method can permit the study of the effect of vasoactive agents on pericytes under the in vivo and normal physiological condition. The specificity of the labeling method was verified by the immunofluorescence labeling of pericyte maker proteins such as desmin, neural proteoglycan (NG2), and thymocyte differentiation antigen 1 (Thy-1). Superfused K(+) and Ca(2+) to the cochlear lateral wall resulted in localized constriction of capillaries at pericyte locations both in vivo and in vitro, while there was no obvious change in cochlear capillary diameters with application of the adrenergic neurotransmitter noradrenaline. The method could be an effective way to visualize cochlear pericytes and microvessels and study lateral wall vascular physiology. Moreover, we demonstrate for the first time that cochlear pericytes have contractility, which may be important for regulation of cochlear blood flow.
Cochlear implants: system design, integration, and evaluation.
Zeng, Fan-Gang; Rebscher, Stephen; Harrison, William; Sun, Xiaoan; Feng, Haihong
2008-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
Sound-direction identification with bilateral cochlear implants.
Neuman, Arlene C; Haravon, Anita; Sislian, Nicole; Waltzman, Susan B
2007-02-01
The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. Eight adults who were bilateral users of Nucleus 24 Contour devices participated in the study. All had received implants in both ears in a single surgery. Sound-direction identification was measured in a large classroom by using a nine-loudspeaker array. Localization was tested in three listening conditions (bilateral cochlear implants, left cochlear implant, and right cochlear implant), using two different stimuli (a speech stimulus and pink noise bursts) in a repeated-measures design. Sound-direction identification accuracy was significantly better when using two implants than when using a single implant. The mean root-mean-square error was 29 degrees for the bilateral condition, 54 degrees for the left cochlear implant, and 46.5 degrees for the right cochlear implant condition. Unilateral accuracy was similar for right cochlear implant and left cochlear implant performance. Sound-direction identification performance was similar for speech and pink noise stimuli. The data obtained in this study add to the growing body of evidence that sound-direction identification with bilateral cochlear implants is better than with a single implant. The similarity in localization performance obtained with the speech and pink noise supports the use of either stimulus for measuring sound-direction identification.
Luo, Xin; Fu, Qian-Jie; Galvin, John J.
2007-01-01
The present study investigated the ability of normal-hearing listeners and cochlear implant users to recognize vocal emotions. Sentences were produced by 1 male and 1 female talker according to 5 target emotions: angry, anxious, happy, sad, and neutral. Overall amplitude differences between the stimuli were either preserved or normalized. In experiment 1, vocal emotion recognition was measured in normal-hearing and cochlear implant listeners; cochlear implant subjects were tested using their clinically assigned processors. When overall amplitude cues were preserved, normal-hearing listeners achieved near-perfect performance, whereas listeners with cochlear implant recognized less than half of the target emotions. Removing the overall amplitude cues significantly worsened mean normal-hearing and cochlear implant performance. In experiment 2, vocal emotion recognition was measured in listeners with cochlear implant as a function of the number of channels (from 1 to 8) and envelope filter cutoff frequency (50 vs 400 Hz) in experimental speech processors. In experiment 3, vocal emotion recognition was measured in normal-hearing listeners as a function of the number of channels (from 1 to 16) and envelope filter cutoff frequency (50 vs 500 Hz) in acoustic cochlear implant simulations. Results from experiments 2 and 3 showed that both cochlear implant and normal-hearing performance significantly improved as the number of channels or the envelope filter cutoff frequency was increased. The results suggest that spectral, temporal, and overall amplitude cues each contribute to vocal emotion recognition. The poorer cochlear implant performance is most likely attributable to the lack of salient pitch cues and the limited functional spectral resolution. PMID:18003871
Beneficial auditory and cognitive effects of auditory brainstem implantation in children.
Colletti, Liliana
2007-09-01
This preliminary study demonstrates the development of hearing ability and shows that there is a significant improvement in some cognitive parameters related to selective visual/spatial attention and to fluid or multisensory reasoning, in children fitted with auditory brainstem implantation (ABI). The improvement in cognitive paramenters is due to several factors, among which there is certainly, as demonstrated in the literature on a cochlear implants (CIs), the activation of the auditory sensory canal, which was previously absent. The findings of the present study indicate that children with cochlear or cochlear nerve abnormalities with associated cognitive deficits should not be excluded from ABI implantation. The indications for ABI have been extended over the last 10 years to adults with non-tumoral (NT) cochlear or cochlear nerve abnormalities that cannot benefit from CI. We demonstrated that the ABI with surface electrodes may provide sufficient stimulation of the central auditory system in adults for open set speech recognition. These favourable results motivated us to extend ABI indications to children with profound hearing loss who were not candidates for a CI. This study investigated the performances of young deaf children undergoing ABI, in terms of their auditory perceptual development and their non-verbal cognitive abilities. In our department from 2000 to 2006, 24 children aged 14 months to 16 years received an ABI for different tumour and non-tumour diseases. Two children had NF2 tumours. Eighteen children had bilateral cochlear nerve aplasia. In this group, nine children had associated cochlear malformations, two had unilateral facial nerve agenesia and two had combined microtia, aural atresia and middle ear malformations. Four of these children had previously been fitted elsewhere with a CI with no auditory results. One child had bilateral incomplete cochlear partition (type II); one child, who had previously been fitted unsuccessfully elsewhere with a CI, had auditory neuropathy; one child showed total cochlear ossification bilaterally due to meningitis; and one child had profound hearing loss with cochlear fractures after a head injury. Twelve of these children had multiple associated psychomotor handicaps. The retrosigmoid approach was used in all children. Intraoperative electrical auditory brainstem responses (EABRs) and postoperative EABRs and electrical middle latency responses (EMLRs) were performed. Perceptual auditory abilities were evaluated with the Evaluation of Auditory Responses to Speech (EARS) battery - the Listening Progress Profile (LIP), the Meaningful Auditory Integration Scale (MAIS), the Meaningful Use of Speech Scale (MUSS) - and the Category of Auditory Performance (CAP). Cognitive evaluation was performed on seven children using the Leiter International Performance Scale - Revised (LIPS-R) test with the following subtests: Figure ground, Form completion, Sequential order and Repeated pattern. No postoperative complications were observed. All children consistently used their devices for >75% of waking hours and had environmental sound awareness and utterance of words and simple sentences. Their CAP scores ranged from 1 to 7 (average =4); with MAIS they scored 2-97.5% (average =38%); MUSS scores ranged from 5 to 100% (average =49%) and LIP scores from 5 to 100% (average =45%). Owing to associated disabilities, 12 children were given other therapies (e.g. physical therapy and counselling) in addition to speech and aural rehabilitation therapy. Scores for two of the four subtests of LIPS-R in this study increased significantly during the first year of auditory brainstem implant use in all seven children selected for cognitive evaluation.
Research on Hearing and Balance--Current and Future Developments.
ERIC Educational Resources Information Center
Snow, James B., Jr.
1997-01-01
This article reviews current research that has located disease genes causing hearing impairments, discovered the ability of sensory cells of the inner ear to regenerate, developed vaccines to prevent otitis media, developed programmable hearing aids, improved cochlear implants, and demonstrated the positive effects of physical therapy with balance…
Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ
Chikar, Jennifer A.; Batts, Shelley A.; Pfingst, Bryan E.; Raphael, Yehoash
2009-01-01
Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament – labeled nerve processes within the scala tympani, and the spatial relationship between them. PMID:19428528
Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.
Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash
2009-05-15
Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.
[Emotional response to music by postlingually-deafened adult cochlear implant users].
Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo
2012-10-01
To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.
The cochlear size of bats and rodents derived from MRI images and histology.
Hsiao, Chun Jen; Jen, Philip Hung-Sun; Wu, Chung Hsin
2015-05-27
From the evolutionary perspective, the ear of each animal species is built for effective processing of the biologically relevant signals used for communication and acoustically guided orientation. Because the sound pulses used by echolocating bats for orientation and rodents for communication are quite different, the basic design of the mammalian auditory system commonly shared by echolocating bats must be specialized in some manner to effectively process their species-specific sounds. The present study examines the difference in the cochlea of these animal species using MRI images and histological techniques. We report here that, although all these animal species share a similar cochlear structure, they vary in their cochlear size and turns. Bats using constant frequency-frequency-modulated pulses (CF-FM bats) and frequency-modulated pulses (FM bats) for echolocation have a larger cochlear size and more cochlear turns than rodents (mice and rats). However, CF-FM bats have the largest cochlear size and most cochlear turns. This difference in cochlear size and turns of these animal species is discussed in relation to their biologically relevant sounds and acoustic behavior.
Guideline on cochlear implants.
Manrique, Manuel; Ramos, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo, Elisa; Lassaleta, Luis; Sanchez-Cuadrado, Isabel; Espinosa, Juan Manuel; Batuecas, Ángel; Cenjor, Carlos; Lavilla, María José; Núñez, Faustino; Cavalle, Laura; Huarte, Alicia
2018-03-26
In the last decade numerous hospitals have started to work with patients who are candidates for a cochlear implant (CI) and there have been numerous and relevant advances in the treatment of sensorineural hearing loss that extended the indications for cochlear implants. To provide a guideline on cochlear implants to specialists in otorhinolaryngology, other medical specialities, health authorities and society in general. The Scientific Committees of Otology, Otoneurology and Audiology from the Spanish Society of Otolaryngology and Head and Neck Surgery (SEORL-CCC), in a coordinated and agreed way, performed a review of the current state of CI based on the existing regulations and in the scientific publications referenced in the bibliography of the document drafted. The clinical guideline on cochlear implants provides information on: a) Definition and description of Cochlear Implant; b) Indications for cochlear implants; c) Organizational requirements for a cochlear implant programme. A clinical guideline on cochlear implants has been developed by a Committee of Experts of the SEORL-CCC, to help and guide all the health professionals involved in this field of CI in decision-making to treathearing impairment. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.
Cochlear implants in children implanted in Jordan: A parental overview.
Alkhamra, Rana A
2015-07-01
Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (p<0.05). Despite the general satisfaction from the information quantity and quality prior to cochlear implant, parents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.
In vivo imaging of mammalian cochlear blood flow using fluorescence microendoscopy.
Monfared, Ashkan; Blevins, Nikolas H; Cheung, Eunice L M; Jung, Juergen C; Popelka, Gerald; Schnitzer, Mark J
2006-02-01
We sought to develop techniques for visualizing cochlear blood flow in live mammalian subjects using fluorescence microendoscopy. Inner ear microcirculation appears to be intimately involved in cochlear function. Blood velocity measurements suggest that intense sounds can alter cochlear blood flow. Disruption of cochlear blood flow may be a significant cause of hearing impairment, including sudden sensorineural hearing loss. However, inability to image cochlear blood flow in a nondestructive manner has limited investigation of the role of inner ear microcirculation in hearing function. Present techniques for imaging cochlear microcirculation using intravital light microscopy involve extensive perturbations to cochlear structure, precluding application in human patients. The few previous endoscopy studies of the cochlea have suffered from optical resolution insufficient for visualizing cochlear microvasculature. Fluorescence microendoscopy is an emerging minimally invasive imaging modality that provides micron-scale resolution in tissues inaccessible to light microscopy. In this article, we describe the use of fluorescence microendoscopy in live guinea pigs to image capillary blood flow and movements of individual red blood cells within the basal turn of the cochlea. We anesthetized eight adult guinea pigs and accessed the inner ear through the mastoid bulla. After intravenous injection of fluorescein dye, we made a limited cochleostomy and introduced a compound doublet gradient refractive index endoscope probe 1 mm in diameter into the inner ear. We then imaged cochlear blood flow within individual vessels in an epifluorescence configuration using one-photon fluorescence microendoscopy. We observed single red blood cells passing through individual capillaries in several cochlear structures, including the round window membrane, spiral ligament, osseous spiral lamina, and basilar membrane. Blood flow velocities within inner ear capillaries varied widely, with observed speeds reaching up to approximately 500 microm/s. Fluorescence microendoscopy permits visualization of cochlear microcirculation with micron-scale optical resolution and determination of blood flow velocities through analysis of video sequences.
Eckhard, A; Müller, M; Salt, A; Smolders, J; Rask-Andersen, H; Löwenheim, H
2014-10-01
The cochlear duct epithelium (CDE) constitutes a tight barrier that effectively separates the inner ear fluids, endolymph and perilymph, thereby maintaining distinct ionic and osmotic gradients that are essential for auditory function. However, in vivo experiments have demonstrated that the CDE allows for rapid water exchange between fluid compartments. The molecular mechanism governing water permeation across the CDE remains elusive. We computationally determined the diffusional (PD) and osmotic (Pf) water permeability coefficients for the mammalian CDE based on in silico simulations of cochlear water dynamics integrating previously derived in vivo experimental data on fluid flow with expression sites of molecular water channels (aquaporins, AQPs). The PD of the entire CDE (PD = 8.18 × 10(-5) cm s(-1)) and its individual partitions including Reissner's membrane (PD = 12.06 × 10(-5) cm s(-1)) and the organ of Corti (PD = 10.2 × 10(-5) cm s(-1)) were similar to other epithelia with AQP-facilitated water permeation. The Pf of the CDE (Pf = 6.15 × 10(-4) cm s(-1)) was also in the range of other epithelia while an exceptionally high Pf was determined for an epithelial subdomain of outer sulcus cells in the cochlear apex co-expressing AQP4 and AQP5 (OSCs; Pf = 156.90 × 10(-3) cm s(-1)). The Pf/PD ratios of the CDE (Pf/PD = 7.52) and OSCs (Pf/PD = 242.02) indicate an aqueous pore-facilitated water exchange and reveal a high-transfer region or "water shunt" in the cochlear apex. This "water shunt" explains experimentally determined phenomena of endolymphatic longitudinal flow towards the cochlear apex. The water permeability coefficients of the CDE emphasise the physiological and pathophysiological relevance of water dynamics in the cochlea in particular for endolymphatic hydrops and Ménière's disease.
Matrix Metalloproteinase Dysregulation in the Stria Vascularis of Mice with Alport Syndrome
Gratton, Michael Anne; Rao, Velidi H.; Meehan, Daniel T.; Askew, Charles; Cosgrove, Dominic
2005-01-01
Alport syndrome results from mutations in genes encoding collagen α3(IV), α4(IV), or α5(IV) and is characterized by progressive glomerular disease associated with a high-frequency sensorineural hearing loss. Earlier studies of a gene knockout mouse model for Alport syndrome noted thickening of strial capillary basement membranes in the cochlea, suggesting that the stria vascularis is the primary site of cochlear pathogenesis. Here we combine a novel cochlear microdissection technique with molecular analyses to illustrate significant quantitative alterations in strial expression of mRNAs encoding matrix metalloproteinases-2, -9, -12, and -14. Gelatin zymography of extracts from the stria vascularis confirmed these findings. Treatment of Alport mice with a small molecule inhibitor of these matrix metalloproteinases exacerbated strial capillary basement membrane thickening, demonstrating that alterations in basement membrane metabolism result in matrix accumulation in the strial capillary basement membranes. This is the first demonstration of true quantitative analysis of specific mRNAs for matrix metalloproteinases in a cochlear microcompartment. Further, these data suggest that the altered basement membrane composition in Alport stria influences the expression of genes involved in basement membrane metabolism. PMID:15855646
Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.
Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan
2011-01-01
With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Liu, Yingpeng; Wang, Guopeng; Shen, Anmin; Wang, Jianting; Chen, Pei; Li, Zeweng; Gong, Shusheng
2007-08-01
To purify P0 protein from guinea pig's inner ear by preparative SDS-PAGE and study the possible role it may play in the etiology of autoimmune inner ear disease. A mixture of membraneous proteins of inner ear was separated by preparative SDS-PAGE. The corresponding band at 30kd was cut and electrically eluted. The protein collected was identified by analytical SDS-PAGE and Western blot assay. A group of 20 guinea pigs were immunized with P0 protein emulsified in complete Freund's adjuvant, another 10 guinea pigs were immunized with complete Freund 's adjuvant only as control. The guinea pigs' hearing thresholds, serum IgG level and morphological changes in the inner ear were investigated. The distribution of P0 protein in the cochlear was detected by immunohistochemical technique. The purity of the protein was demonstrated by a single band at the 30 kD site in SDS-PAGE, which was identified as P0 protein by western blot analysis assay. About 17.5% P0-immunized guinea pigs showed increased hearing thresholds, elevated IgG level (F =6.48, P <0. 01), as well as a decreased number of spiral ganglion cells and inflammatory cell infiltration in the cochlear nerve region. The P0 protein is distributed in the cochlear nerve and spiral ganglion only. P0 protein from guinea pig's inner ear can be successfully purified by preparative SDS-PAGE and an animal model of experimental autoimmune inner ear disease induced by P0 protein is successfully established.
Pinyon, Jeremy L; Tadros, Sherif F; Froud, Kristina E; Y Wong, Ann C; Tompson, Isabella T; Crawford, Edward N; Ko, Myungseo; Morris, Renée; Klugmann, Matthias; Housley, Gary D
2014-04-23
The cochlear implant is the most successful bionic prosthesis and has transformed the lives of people with profound hearing loss. However, the performance of the "bionic ear" is still largely constrained by the neural interface itself. Current spread inherent to broad monopolar stimulation of the spiral ganglion neuron somata obviates the intrinsic tonotopic mapping of the cochlear nerve. We show in the guinea pig that neurotrophin gene therapy integrated into the cochlear implant improves its performance by stimulating spiral ganglion neurite regeneration. We used the cochlear implant electrode array for novel "close-field" electroporation to transduce mesenchymal cells lining the cochlear perilymphatic canals with a naked complementary DNA gene construct driving expression of brain-derived neurotrophic factor (BDNF) and a green fluorescent protein (GFP) reporter. The focusing of electric fields by particular cochlear implant electrode configurations led to surprisingly efficient gene delivery to adjacent mesenchymal cells. The resulting BDNF expression stimulated regeneration of spiral ganglion neurites, which had atrophied 2 weeks after ototoxic treatment, in a bilateral sensorineural deafness model. In this model, delivery of a control GFP-only vector failed to restore neuron structure, with atrophied neurons indistinguishable from unimplanted cochleae. With BDNF therapy, the regenerated spiral ganglion neurites extended close to the cochlear implant electrodes, with localized ectopic branching. This neural remodeling enabled bipolar stimulation via the cochlear implant array, with low stimulus thresholds and expanded dynamic range of the cochlear nerve, determined via electrically evoked auditory brainstem responses. This development may broadly improve neural interfaces and extend molecular medicine applications.
Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M
2012-06-01
The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
[The development of musicality in children after cochlear implantation].
Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing
2014-08-01
The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (P<0.05). The mean scores of musicality also showed significant improvements with time for control group (P<0.05). There were no significant differences in mean scores between CI group and control group at 1, 3, 6, 9, 12 months of hearing age by rank sum test (P>0.05). Significant difference was noted between the two groups at 24 months (P<0.05). The musicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.
Cochlear Implants:System Design, Integration and Evaluation
Rebscher, Stephen; Harrison, William V.; Sun, Xiaoan; Feng, Haihong
2009-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120,000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues from design and specifications to integration and evaluation. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants. PMID:19946565
Remote programming of cochlear implants: a telecommunications model.
McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S
2010-09-01
Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.
Music mixing preferences of cochlear implant recipients: a pilot study.
Buyens, Wim; van Dijk, Bas; Moonen, Marc; Wouters, Jan
2014-05-01
Music perception and appraisal are generally poor in cochlear implant recipients. Simple musical structures, lyrics that are easy to follow, and clear rhythm/beat have been reported among the top factors to enhance music enjoyment. The present study investigated the preference for modified relative instrument levels in music with normal-hearing and cochlear implant subjects. In experiment 1, test subjects were given a mixing console and multi-track recordings to determine their most enjoyable audio mix. In experiment 2, a preference rating experiment based on the preferred relative level settings in experiment 1 was performed. Experiment 1 was performed with four postlingually deafened cochlear implant subjects, experiment 2 with ten normal-hearing and ten cochlear implant subjects. A significant difference in preference rating was found between normal-hearing and cochlear implant subjects. The latter preferred an audio mix with larger vocals-to-instruments ratio. In addition, given an audio mix with clear vocals and attenuated instruments, cochlear implant subjects preferred the bass/drum track to be louder than the other instrument tracks. The original audio mix in real-world music might not be suitable for cochlear implant recipients. Modifying the relative instrument level settings potentially improves music enjoyment.
Bertlich, Mattis; Ihler, Friedrich; Weiss, Bernhard G; Freytag, Saskia; Jakob, Mark; Strupp, Michael; Pellkofer, Hannah; Canis, Martin
2017-09-01
The potential of Fingolimod (FTY-720), a sphingosine-1-phosphate analogue, to revoke the changes in cochlear blood flow induced by tumor necrosis factor (TNF) was investigated. Impairment of cochlear blood flow has often been considered as the common final pathway of various inner ear pathologies. TNF, an ubiquitous cytokine, plays a major role in these pathologies, reducing cochlear blood flow via sphingosine-1-phosphate-signaling. Fifteen Dunkin-Hartley guinea pigs were randomly assigned to one of three groups (placebo/placebo, TNF/placebo, TNF/FTY-720). Cochlear microcirculation was quantified over 60 minutes by in vivo fluorescence microscopy before and after topical application of placebo or TNF (5 ng/ml) and after subsequent application of placebo or FTY-720 (200 μg/ml). Treatment with TNF led to a significant decrease of cochlear blood flow.Following this, application of placebo caused no significant changes while application of FTY-720 caused a significant rise in cochlear blood flow. FTY-720 is capable of reversing changes in cochlear blood flow induced by application of TNF. This makes FTY-720 a valid candidate for potential treatment of numerous inner ear pathologies.
[Cochlear implantation in patients with Waardenburg syndrome type II].
Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian
2010-05-01
To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.
[Cochlear implantation through the middle fossa approach].
Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M
2001-01-01
The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.
United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.
Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark
2013-11-01
Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.
Tabuchi, Keiji; Nishimura, Bungo; Tanaka, Shuho; Hayashi, Kentaro; Hirose, Yuki; Hara, Akira
2010-06-01
A large amount of energy produced by active aerobic metabolism is necessary for the cochlea to maintain its function. This makes the cochlea vulnerable to blockade of cochlear blood flow and interruption of the oxygen supply. Although certain forms of human idiopathic sudden sensorineural hearing loss reportedly arise from ischemic injury, the pathological mechanism of cochlear ischemia-reperfusion injury has not been fully elucidated. Recent animal studies have shed light on the mechanisms of cochlear ischemia-reperfusion injury. It will help in the understanding of the pathology of cochlear ischemia-reperfusion injury to classify this injury into ischemic injury and reperfusion injury. Excitotoxicity, mainly observed during the ischemic period, aggravates the injury of primary auditory neurons. On the other hand, oxidative damage induced by hydroxyl radicals and nitric oxide enhances cochlear reperfusion injury. This article briefly summarizes the generation mechanisms of cochlear ischemia-reperfusion injury and potential therapeutic targets that could be developed for the effective management of this injury type.
Musical ear syndrome in adult cochlear implant patients.
Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W
2013-09-01
Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.
Importance of cochlear health for implant function.
Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A
2015-04-01
Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled
The influence of cochlear shape on low-frequency hearing.
Manoussaki, Daphne; Chadwick, Richard S; Ketten, Darlene R; Arruda, Julie; Dimitriadis, Emilios K; O'Malley, Jen T
2008-04-22
The conventional theory about the snail shell shape of the mammalian cochlea is that it evolved essentially and perhaps solely to conserve space inside the skull. Recently, a theory proposed that the spiral's graded curvature enhances the cochlea's mechanical response to low frequencies. This article provides a multispecies analysis of cochlear shape to test this theory and demonstrates that the ratio of the radii of curvature from the outermost and innermost turns of the cochlear spiral is a significant cochlear feature that correlates strongly with low-frequency hearing limits. The ratio, which is a measure of curvature gradient, is a reflection of the ability of cochlear curvature to focus acoustic energy at the outer wall of the cochlear canal as the wave propagates toward the apex of the cochlea.
Zaslavskiĭ, A Iu; Sapozhnikov, Ia M; Markarov, G S; Gelis, Iu S
1995-01-01
To enhance effectiveness of magnetotherapy in the treatment of otic diseases the authors propose to use impulse low-frequency electromagnetic field in combination with constant magnetic field. ELEMAGS equipment based on the above principles is introduced to treat cochlear neuritis and neurosensory hypoacusis in children.
Working memory in Farsi-speaking children with normal development and cochlear implant.
Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre
2014-04-01
Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p < 0.001). The children's age at implantation was negatively correlated with all tasks (p < 0.001). In contrast, duration of usage of cochlear implant set was positively correlated with all tasks (p < 0.001). The comparison of working memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p < 0.05). These results implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Chang, David T; Ko, Alvin B; Murray, Gail S; Arnold, James E; Megerian, Cliff A
2010-07-01
(1) To analyze if socioeconomic status influences access to cochlear implantation in an environment with adequate Medicaid reimbursement. (2) To determine the impact of socioeconomic status on outcomes after unilateral cochlear implantation. Retrospective cohort study. University Hospitals Case Medical Center and Rainbow Babies and Children's Hospital (tertiary referral center), Cleveland, Ohio. Pediatric patients (age range, newborn to 18 years) who received unilateral cochlear implantation during the period 1996 to 2008. Access to cochlear implantation after referral to a cochlear implant center, postoperative complications, compliance with follow-up appointments, and access to sequential bilateral cochlear implantation. A total of 133 pediatric patients were included in this study; 64 were Medicaid-insured patients and 69 were privately insured patients. There was no statistical difference in the odds of initial cochlear implantation, age at referral, or age at implantation between the 2 groups. The odds of prelingual Medicaid-insured patients receiving sequential bilateral cochlear implantation was less than half that of the privately insured group (odds ratio [OR], 0.43; P = .03). The odds of complications in Medicaid-insured children were almost 5-fold greater than the odds for privately insured children (OR, 4.6; P = .03). There were 10 complications in 51 Medicaid-insured patients (19.6%) as opposed to 3 in 61 privately insured patients (4.9%). Medicaid-insured patients missed substantially more follow-up appointments overall (35% vs 23%) and more consecutive visits (1.9 vs 1.1) compared with privately insured patients. In an environment with adequate Medicaid reimbursement, eligible children have equal access to cochlear implantation, regardless of socioeconomic background. However, lower socioeconomic background is associated with higher rates of postoperative complications, worse follow-up compliance, and lower rates of sequential bilateral implantation, observed herein in Medicaid-insured patients. These findings present opportunities for cochlear implant centers to create programs to address such downstream disparities.
Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon
2018-05-18
Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Moein, Narges; Khoddami, Seyyedeh Maryam; Shahbodaghi, Mohammad Rahim
2017-10-01
Cochlear implant prosthesis facilitates spoken language development and speech comprehension in children with severe-profound hearing loss. However, this prosthesis is limited in encoding information about fundamental frequency and pitch that are essentially for recognition of speech prosody. The purpose of the present study is to investigate the perception and production of intonation in cochlear implant children and comparison with normal hearing children. This study carried out on 25 cochlear implanted children and 50 children with normal hearing. First, using 10 action pictures statements and questions sentences were extracted. Fundamental frequency and pitch changes were identified using Praat software. Then, these sentences were judged by 7 adult listeners. In second stage 20 sentences were played for child and he/she determined whether it was in a question form or statement one. Performance of cochlear implanted children in perception and production of intonation was significantly lower than children with normal hearing. The difference between fundamental frequency and pitch changes in cochlear implanted children and children with normal hearing was significant (P < 0/05). Cochlear implanted children performance in perception and production of intonation has significant correlation with child's age surgery and duration of prosthesis use (P < 0/05). The findings of the current study show that cochlear prostheses have limited application in facilitating the perception and production of intonation in cochlear implanted children. It should be noted that the child's age at the surgery and duration of prosthesis's use is important in reduction of this limitation. According to these findings, speech and language pathologists should consider intervention of intonation in treatment program of cochlear implanted children. Copyright © 2017 Elsevier B.V. All rights reserved.
Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J
2017-06-01
Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve. © 2017 by American Journal of Neuroradiology.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
Response Properties of Cochlear Nucleus Neurons in Monkeys
Roth, G. Linn; Recio, A.
2009-01-01
Much of what is known about how the cochlear nuclei participate in mammalian hearing comes from studies of non-primate mammalian species. To determine to what extent the cochlear nuclei of primates resemble those of other mammalian orders, we have recorded responses to sound in three primate species: marmosets, Cynomolgus macaques, and squirrel monkeys. These recordings show that the same types of temporal firing patterns are found in primates that have been described in other mammals. Responses to tones of neurons in the ventral cochlear nucleus have similar tuning, latencies, post-stimulus time and interspike interval histograms as those recorded in non-primate cochlear nucleus neurons. In the dorsal cochlear nucleus, too, responses were similar. From these results it is evident that insights gained from non-primate studies can be applied to the peripheral auditory system of primates. PMID:19531377
Monshizadeh, Leila; Vameghi, Roshanak; Sajedi, Firoozeh; Yadegari, Fariba; Hashemi, Seyed Basir; Kirchem, Petra; Kasbi, Fatemeh
2018-04-01
A cochlear implant is a device that helps hearing-impaired children by transmitting sound signals to the brain and helping them improve their speech, language, and social interaction. Although various studies have investigated the different aspects of speech perception and language acquisition in cochlear-implanted children, little is known about their social skills, particularly Persian-speaking cochlear-implanted children. Considering the growing number of cochlear implants being performed in Iran and the increasing importance of developing near-normal social skills as one of the ultimate goals of cochlear implantation, this study was performed to compare the social interaction between Iranian cochlear-implanted children who have undergone rehabilitation (auditory verbal therapy) after surgery and normal-hearing children. This descriptive-analytical study compared the social interaction level of 30 children with normal hearing and 30 with cochlear implants who were conveniently selected. The Raven test was administered to the both groups to ensure normal intelligence quotient. The social interaction status of both groups was evaluated using the Vineland Adaptive Behavior Scale, and statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 21. After controlling age as a covariate variable, no significant difference was observed between the social interaction scores of both the groups (p > 0.05). In addition, social interaction had no correlation with sex in either group. Cochlear implantation followed by auditory verbal rehabilitation helps children with sensorineural hearing loss to have normal social interactions, regardless of their sex.
Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.
Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo
2017-09-01
to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.
Use of suprathreshold stochastic resonance in cochlear implant coding
NASA Astrophysics Data System (ADS)
Allingham, David; Stocks, Nigel G.; Morse, Robert P.
2003-05-01
In this article we discuss the possible use of a novel form of stochastic resonance, termed suprathreshold stochastic resonance (SSR), to improve signal encoding/transmission in cochlear implants. A model, based on the leaky-integrate-and-fire (LIF) neuron, has been developed from physiological data and use to model information flow in a population of cochlear nerve fibers. It is demonstrated that information flow can, in principle, be enhanced by the SSR effect. Furthermore, SSR was found to enhance information transmission for signal parameters that are commonly encountered in cochlear implants. This, therefore, gives hope that SSR may be implemented in cochlear implants to improve speech comprehension.
Round-window delivery of neurotrophin 3 regenerates cochlear synapses after acoustic overexposure.
Suzuki, Jun; Corfas, Gabriel; Liberman, M Charles
2016-04-25
In acquired sensorineural hearing loss, such as that produced by noise or aging, there can be massive loss of the synaptic connections between cochlear sensory cells and primary sensory neurons, without loss of the sensory cells themselves. Because the cell bodies and central projections of these cochlear neurons survive for months to years, there is a long therapeutic window in which to re-establish functional connections and improve hearing ability. Here we show in noise-exposed mice that local delivery of neurotrophin-3 (NT-3) to the round window niche, 24 hours after an exposure that causes an immediate loss of up to 50% loss of synapses in the cochlear basal region, can regenerate pre- and post-synaptic elements at the hair cell / cochlear nerve interface. This synaptic regeneration, as documented by confocal microscopy of immunostained cochlear sensory epithelia, was coupled with a corresponding functional recovery, as seen in the suprathreshold amplitude of auditory brainstem response Wave 1. Cochlear delivery of neurotrophins in humans is likely achievable as an office procedure via transtympanic injection, making our results highly significant in a translational context.
Prevention of Noise Damage to Cochlear Synapses
2015-10-01
AWARD NUMBER: W81XWH-14-1-0494 TITLE: Prevention of Noise Damage to Cochlear Synapses PRINCIPAL INVESTIGATOR: Steven Green CONTRACTING...to Cochlear Synapses 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-1-0494 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Steven Green 5d. PROJECT...ABSTRACT Noise-induced synaptopathy is the result of excitotoxic trauma to cochlear synapses due to glutamate released from the hair cells. Excitotoxic
Preventing Ototoxic Synergy of Prior Noise Trauma During Aminoglycoside Therapy
2015-12-01
cochlear blood flow . Hearing Research 313, 38-46 (2014). 12. Koo, J.-W. et al. Endotoxemia-mediated inflammation potentiates cochlear uptake of...event in response to a need for higher cochlear blood flow . A 3.7% dilation was adequate for a 20% increase of blood flow 10. On the contrary...summation of the two insults. We have found that prior sound exposure enhances cochlear uptake of aminoglycosides, providing a mechanistic basis for the
Spiral Form of the Human Cochlea Results from Spatial Constraints.
Pietsch, M; Aguirre Dávila, L; Erfurt, P; Avci, E; Lenarz, T; Kral, A
2017-08-08
The human inner ear has an intricate spiral shape often compared to shells of mollusks, particularly to the nautilus shell. It has inspired many functional hearing theories. The reasons for this complex geometry remain unresolved. We digitized 138 human cochleae at microscopic resolution and observed an astonishing interindividual variability in the shape. A 3D analytical cochlear model was developed that fits the analyzed data with high precision. The cochlear geometry neither matched a proposed function, namely sound focusing similar to a whispering gallery, nor did it have the form of a nautilus. Instead, the innate cochlear blueprint and its actual ontogenetic variants were determined by spatial constraints and resulted from an efficient packing of the cochlear duct within the petrous bone. The analytical model predicts well the individual 3D cochlear geometry from few clinical measures and represents a clinical tool for an individualized approach to neurosensory restoration with cochlear implants.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management. PMID:15247993
Ion flow in cochlear hair cells and the regulation of hearing sensitivity.
Patuzzi, Robert
2011-10-01
This paper discusses how ion transport proteins in the hair cells of the mammalian cochlea work to produce a sensitive but stable hearing organ. The transport proteins in the inner and outer hair cells are summarized (including their current voltage characteristics), and the roles of these proteins in determining intracellular Ca(2+), membrane potential, and ultimately cochlear sensitivity are discussed. The paper also discusses the role of the Ca(2+) sequestration sacs in outer hair cells in the autoregulation of hair cell membrane potential and cochlear gain, and how the underdamped control of Ca(2+) within these sacs may produce the observed slow oscillations in cochlear sensitivity and otoacoustic emissions after cochlear perturbations, including perilymphatic perfusions and prolonged low-frequency tones. The relative insensitivity of cochlear gain to short-term changes in the endocochlear potential is also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.
The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.
Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2016-01-01
Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.
The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome
Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2016-01-01
Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome. PMID:27376080
Should children who use cochlear implants wear hearing aids in the opposite ear?
Ching, T Y; Psarros, C; Hill, M; Dillon, H; Incerti, P
2001-10-01
The aim of this study was to investigate 1) whether a hearing aid needs to be adjusted differently depending on whether a child wears a cochlear implant or another hearing aid in the contralateral ear; 2) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural interference; and 3) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural benefits in speech perception, localization, and communicative functioning in real life. Sixteen children participated in this study. All children used a Nucleus 22 or Nucleus 24 cochlear implant system programmed with the SPEAK strategy in one ear. The hearing aid amplification requirements in the nonimplanted ear of these children were determined using two procedures. A paired comparison technique was used to identify the frequency response that was best for speech intelligibility in quiet, and a loudness balancing technique was used to match the loudness of speech in the ear with a hearing aid to that with a cochlear implant. Eleven of the 16 children participated in the investigation of binaural effects. Performance in speech perception, localization, and communicative functioning was assessed under four aided conditions: cochlear implant with hearing aid as worn, cochlear implant alone, hearing aid alone, and cochlear implant with hearing aid adjusted according to individual requirements. Fifteen of the 16 children whose amplification requirements were determined preferred a hearing aid frequency response that was within +/-6 dB/octave of the NAL-RP prescription. On average, the children required 6 dB more gain than prescribed to balance the loudness of the implanted ear for a speech signal presented at 65 dB SPL. For all 11 children whose performance was evaluated for investigating binaural effects, there was no indication of significantly poorer performance under bilaterally aided conditions compared with unilaterally aided conditions. On average, there were significant benefits in speech perception, localization, and aural/oral function when the children used cochlear implants with adjusted hearing aids than when they used cochlear implants alone. All individuals showed benefits in at least one of the measures. Hearing aids for children who also use cochlear implants can be selected using the NAL-RP prescription. Adjustment of hearing aid gain to match loudness in the implanted ear can facilitate integration of signals from both ears, leading to better speech perception. Given that there are binaural advantages from using cochlear implants with hearing aids in opposite ears, clinicians should advise parents and other professionals about these potential advantages, and facilitate bilateral amplification by adjusting hearing aids after stable cochlear implant MAPs are established.
Francis, Howard W; Pulsifer, Margaret B; Chinnici, Jill; Nutt, Robert; Venick, Holly S; Yeagle, Jennifer D; Niparko, John K
2004-05-01
This study explored factors associated with speech recognition outcomes in postmeningitic deafness (PMD). The results of cochlear implantation may vary in children with PMD because of sequelae that extend beyond the auditory periphery. To determine which factors might be most determinative of outcome of cochlear implantation in children with PMD. Retrospective chart review. A referral center for pediatric cochlear implantation and rehabilitation. Thirty children with cochlear implants who were deafened by meningitis were matched with subjects who were deafened by other causes based on the age at diagnosis, age at cochlear implantation, age at which hearing aids were first used, and method of communication used at home or in the classroom. Speech perception performance within the first 2 years after cochlear implantation and its relationship with presurgical cognitive measures and medical history. There was no difference in the overall cognitive or postoperative speech perception performance between the children with PMD and those deafened by other causes. The presence of postmeningitic hydrocephalus, however, posed greater challenges to the rehabilitation process, as indicated by significantly smaller gains in speech perception and a predilection for behavioral problems. By comparison, cochlear scarring and incomplete electrode insertion had no impact on speech perception results. Although the results demonstrated no significant delay in cognitive or speech perception performance in the PMD group, central nervous system residua, when present, can impede the acquisition of speech perception with a cochlear implant. Central effects associated with PMD may thus impact language learning potential; cognitive and behavioral therapy should be considered in rehabilitative planning and in establishing expectations of outcome.
Banakis Hartl, Renee M; Mattingly, Jameson K; Greene, Nathaniel T; Jenkins, Herman A; Cass, Stephen P; Tollin, Daniel J
2016-10-01
A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative ABG remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative ABG. Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with previous literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable after electrode placement. Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity.
Gimñenez, F; Carbonell, R; Pérez, F; Lozano, I
1994-01-01
Reporting one case of this condition type-2 with heterochromia iridis and cochlear deafness. The AA. review the syndrome's components and it nomenclature as well. They discuss about the convenience of including this deviation in the chapter of "diseases of the embryonic neural crest". The specific place of the gene responsibly in the chromosome-2 and the possibilities of genetic counselling are considered.
Inner ear changes in mucopolysaccharidosis type I/Hurler syndrome.
Kariya, Shin; Schachern, Patricia A; Nishizaki, Kazunori; Paparella, Michael M; Cureoglu, Sebahattin
2012-10-01
Mucopolysaccharidosis type I/Hurler syndrome is an autosomal recessive disease caused by a deficiency of α-L-iduronidase activity. Recurrent middle ear infections and hearing loss are common complications in Hurler syndrome. Although sensorineural and conductive components occur, the mechanism of sensorineural hearing loss has not been determined. The purpose of this study is to evaluate the quantitative inner ear histopathology of the temporal bones of patients with Hurler syndrome. Eleven temporal bones from 6 patients with Hurler syndrome were examined. Age-matched healthy control samples consisted of 14 temporal bones from 7 cases. Temporal bones were serially sectioned in the horizontal plane and stained with hematoxylin and eosin. The number of spiral ganglion cells, loss of cochlear hair cells, area of stria vascularis, and cell density of spiral ligament were evaluated using light microscopy. There was no significant difference between Hurler syndrome and healthy controls in the number of spiral ganglion cells, area of stria vascularis, or cell density of spiral ligament. The number of cochlear hair cells in Hurler syndrome was significantly decreased compared with healthy controls. Auditory pathophysiology in the central nerve system in Hurler syndrome remains unknown; however, decreased cochlear hair cells may be one of the important factors for the sensorineural component of hearing loss.
Orendorz-Fraczkowska, Krystyna; Jaworska, Marzena; Gawron, Wojciech; Badowski, Roman; Nadolska, Beata
2007-01-01
Symptoms encompassing sensorineural hearing loss, tinnitus and vertigo occur in many diseases of various origin. The diagnostics in such cases is especially difficult and often requires interdisciplinary cooperation. Despite of that many cases remain unexplained. The two cases with above mentioned symptoms (52 year-old woman and 46 year-old man) with differentiated clinical course were presented. The woman for one year experienced left sided, extreme tinnitus with paroxysmal vertigo and dizziness. The man with sudden monolateral hearing loss and tinnitus that disappeared after corticosteroid therapy, complained about recurrence of fluctuating hearing loss and tinnitus accompanied by chronic instability. The diagnostics of hearing and balance organs was performed (pure tone audiometry, impedance audiometry, DPOAE, ABR, ENG) complemented with computed tomography and Nuclear Resonance. Female patient presented bilateral mild sensorineural hearing loss, more intensive on the left side, male patient right sided sensorineural hearing loss in the frequencies from 250 to 1500 Hz. The elongation of some peak values in ABR test (with bilaterally proper otoacoustic emissions) as well as partial canal paresis on the hearing loss side suggested primary diagnosis of neoplasmatic process. It was an indication to perform radiological diagnostics. The radiologic findings revealed the contact of vestibulo-cochlear nerve with the loop of cerebellar inferior anterior artery within the internal acoustic canal. The course of the disease and diagnostic tests do not provide characteristic data that let diagnose neuro-vascular conflict. One has to be aware of such possibility in patients with intensive vertigo and dizziness that do not improve after treatment when other causes do not justify the symptoms.
Cochlear implants in Waardenburg syndrome.
Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig
2006-07-01
Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.
Surgical Management of the Pediatric Cochlear Implant Patient.
ERIC Educational Resources Information Center
Cohen, Seth M.; Haynes, David S.
2003-01-01
This article discusses the surgical management of children receiving cochlear implants. It identifies preoperative considerations to select patients likely to benefit, contraindications, some new surgical techniques, complications, special considerations (otitis media, meningitis, head growth, inner ear malformations, and cochlear obstruction).…
Dunn, Camille C.; Perreau, Ann; Gantz, Bruce; Tyler, Richard
2009-01-01
Background Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. Purpose The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech in noise test with spatially-separate noise sources. Research Design Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all eleven subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Conclusion Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise. PMID:20085199
Dunn, Camille C; Perreau, Ann; Gantz, Bruce; Tyler, Richard S
2010-01-01
Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech-in-noise test with spatially separate noise sources. Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all 11 subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise.
Quantitative polarized light microscopy of unstained mammalian cochlear sections
NASA Astrophysics Data System (ADS)
Kalwani, Neil M.; Ong, Cheng Ai; Lysaght, Andrew C.; Haward, Simon J.; McKinley, Gareth H.; Stankovic, Konstantina M.
2013-02-01
Hearing loss is the most common sensory deficit in the world, and most frequently it originates in the inner ear. Yet, the inner ear has been difficult to access for diagnosis because of its small size, delicate nature, complex three-dimensional anatomy, and encasement in the densest bone in the body. Evolving optical methods are promising to afford cellular diagnosis of pathologic changes in the inner ear. To appropriately interpret results from these emerging technologies, it is important to characterize optical properties of cochlear tissues. Here, we focus on that characterization using quantitative polarized light microscopy (qPLM) applied to unstained cochlear sections of the mouse, a common animal model of human hearing loss. We find that the most birefringent cochlear materials are collagen fibrils and myelin. Retardance of the otic capsule, the spiral ligament, and the basilar membrane are substantially higher than that of other cochlear structures. Retardance of the spiral ligament and the basilar membrane decrease from the cochlear base to the apex, compared with the more uniform retardance of other structures. The intricate structural details revealed by qPLM of unstained cochlear sections ex vivo strongly motivate future application of polarization-sensitive optical coherence tomography to human cochlea in vivo.
Quantitative polarized light microscopy of unstained mammalian cochlear sections
Kalwani, Neil M.; Ong, Cheng Ai; Lysaght, Andrew C.; Haward, Simon J.; McKinley, Gareth H.
2013-01-01
Abstract. Hearing loss is the most common sensory deficit in the world, and most frequently it originates in the inner ear. Yet, the inner ear has been difficult to access for diagnosis because of its small size, delicate nature, complex three-dimensional anatomy, and encasement in the densest bone in the body. Evolving optical methods are promising to afford cellular diagnosis of pathologic changes in the inner ear. To appropriately interpret results from these emerging technologies, it is important to characterize optical properties of cochlear tissues. Here, we focus on that characterization using quantitative polarized light microscopy (qPLM) applied to unstained cochlear sections of the mouse, a common animal model of human hearing loss. We find that the most birefringent cochlear materials are collagen fibrils and myelin. Retardance of the otic capsule, the spiral ligament, and the basilar membrane are substantially higher than that of other cochlear structures. Retardance of the spiral ligament and the basilar membrane decrease from the cochlear base to the apex, compared with the more uniform retardance of other structures. The intricate structural details revealed by qPLM of unstained cochlear sections ex vivo strongly motivate future application of polarization-sensitive optical coherence tomography to human cochlea in vivo. PMID:23407909
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jae Ho; Pradhan, Jonu; Maskey, Dhiraj
Research highlights: {yields} Glutamate co-transmission is enhanced in kanamycin-treated rats. {yields} VGLUT3 expression is increased in kanamycin-treated rats. {yields} GlyR expression is decreased in kanamycin-treated rats. {yields} GlyR, VGLUT3 expression patterns are asymmetric in unilaterally cochlear ablated rat. -- Abstract: Cochlear dependency of glutamate co-transmission at the medial nucleus of the trapezoid body (MNTB) - the lateral superior olive (LSO) synapses was investigated using developing rats treated with high dose kanamycin. Rats were treated with kanamycin from postnatal day (P) 3 to P8. A scanning electron microscopic study on P9 demonstrated partial cochlear hair cell damage. A whole cell voltagemore » clamp experiment demonstrated the increased glutamatergic portion of postsynaptic currents (PSCs) elicited by MNTB stimulation in P9-P11 kanamycin-treated rats. The enhanced VGLUT3 immunoreactivities (IRs) in kanamycin-treated rats and asymmetric VGLUT3 IRs in the LSO of unilaterally cochlear ablated rats supported the electrophysiologic data. Taken together, it is concluded that glutamate co-transmission is cochlear-dependent and enhanced glutamate co-transmission in kanamycin-treated rats is induced by partial cochlear damage.« less
Acute hyperfibrinogenemia impairs cochlear blood flow and hearing function in guinea pigs in vivo.
Ihler, Fritz; Strieth, Sebastian; Pieri, Nicos; Göhring, Peter; Canis, Martin
2012-03-01
Impairment of microcirculation is a possible cause of sudden sensorineural hearing loss (SSNHL). Fibrinogen is known as a risk factor for both microvascular dysfunction and SSNHL. Therefore, the aim of this study was to investigate the effect of elevated serum levels of fibrinogen on cochlear blood flow and hearing function in vivo. One group of guinea pigs received two consecutive injections of 100 mg fibrinogen while a control group received equimolar doses of albumin. Measurements of cochlear microcirculation by intravital microscopy and of hearing thresholds by auditory brainstem response (ABR) recordings were carried out before, after first and after second injection. Ten healthy guinea pigs were randomly assigned to a treatment group or a control group of five animals each. Serum fibrinogen levels were elevated after the first and second injections of fibrinogen compared to basal values and control group respectively. Increasing levels of fibrinogen were paralleled by decreasing cochlear blood flow as well as increasing hearing thresholds. Hearing threshold correlated negatively with cochlear blood flow. The effect of microcirculatory impairment on hearing function could be explained by a malfunction of the cochlear amplifier. Further investigation is needed to quantify cochlear potentials under elevated serum fibrinogen levels.
Arnold, W; Bredberg, G; Gstöttner, W; Helms, J; Hildmann, H; Kiratzidis, T; Müller, J; Ramsden, R T; Roland, P; Walterspiel, J N
2002-01-01
Pneumococcal otogenic meningitis is a rare postsurgical complication that can develop following stapedectomy or after cochlear implantation. The bacterial infection can be fatal in some instances. A recent increase in the incidence of otogenic meningitis among cochlear implant wearers is of concern. The majority of meningitis cases are associated with a 2-component electrode manufactured by one cochlear implant company. The device with the added 'positioner' component has been withdrawn from the market (FDA Public Health Web Notification: Cochlear Implant Recipients may be at Greater Risk for Meningitis, Updated: August 29, 2002, www.fda.gov/cdrh/safety/cochlear.html). Not all cases have been subsequent to otitis media and symptoms have developed from less than 24 h up to a few years after implantation. The purpose of this paper is to review and discuss the pathogenesis, pathology/bacteriology and to elaborate on some clinical features of otogenic meningitis in implanted children and adults. Essential aspects of surgery, electrode design, and cochleostomy seal are discussed. Conclusions are drawn from the available data and recommendations are made for good practice in cochlear implantation and follow-up. Copyright 2002 S. Karger AG, Basel
The development of the Nucleus Freedom Cochlear implant system.
Patrick, James F; Busby, Peter A; Gibson, Peter J
2006-12-01
Cochlear Limited (Cochlear) released the fourth-generation cochlear implant system, Nucleus Freedom, in 2005. Freedom is based on 25 years of experience in cochlear implant research and development and incorporates advances in medicine, implantable materials, electronic technology, and sound coding. This article presents the development of Cochlear's implant systems, with an overview of the first 3 generations, and details of the Freedom system: the CI24RE receiver-stimulator, the Contour Advance electrode, the modular Freedom processor, the available speech coding strategies, the input processing options of Smart Sound to improve the signal before coding as electrical signals, and the programming software. Preliminary results from multicenter studies with the Freedom system are reported, demonstrating better levels of performance compared with the previous systems. The final section presents the most recent implant reliability data, with the early findings at 18 months showing improved reliability of the Freedom implant compared with the earlier Nucleus 3 System. Also reported are some of the findings of Cochlear's collaborative research programs to improve recipient outcomes. Included are studies showing the benefits from bilateral implants, electroacoustic stimulation using an ipsilateral and/or contralateral hearing aid, advanced speech coding, and streamlined speech processor programming.
Benito-González, Fernando; Benito, Jose; Sánchez, Luis Alberto Guardado; Estevez Alonso, Santiago; Muñoz Herrera, Angel; Batuecas-Caletrio, Angel
2014-09-01
The objective was to report the effectiveness of salvage treatment in soft tissue infection around cochlear implants with an absorbable gentamicin collagen sheet and a periosteum and skin rotation flaps. Three patients with cochlear implant and persistent surrounding soft tissue infection are included. All of them underwent antibiotic treatment prior to surgery without any response. In this study preoperative and postoperative audiograms were practiced. Surgical excision of infectious skin and a periosteum and skin rotation flaps were performed. The cochlear implant was refixed in the temporal bone and a gentamicin-impregnated collagen sheet was located covering the cochlear implant. headings In all patients with soft tissue infection around the cochlear implant, infection was completely resolved. It was not necessary to remove the device in any case. The use of an absorbable gentamicin-impregnated collagen sheet is not described for the management of soft tissue complications in pediatric cochlear implant patients. The local application of high concentrations of antibiotic administered by this sheet may be effective against resistant bacteria and, in conjunction with surgery, may resolve this type of complications.
Cochlear Implantation after Bilateral Transverse Temporal Bone Fractures
Shin, Jong-Heon; Park, SooChan; Baek, Sam-Hyun
2008-01-01
Patients deafened by a severe head injury are rarely encountered. We report a case of a 65-yr-old man with bilateral transverse temporal bone fractures due to head injury. He underwent cochlear implant and achieved a satisfactory auditory rehabilitation. Imaging studies of temporal bone before performing a cochlear implantation provide important information on a patient with bilateral temporal bone fractures. Cochlear implantations with careful planning in such a patient may be a very effective method for aural rehabilitation. PMID:19434252
Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn
2016-11-01
This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Banakis Hartl, Renee M.; Mattingly, Jameson K.; Greene, Nathaniel T.; Jenkins, Herman A.; Cass, Stephen P.; Tollin, Daniel J.
2016-01-01
Hypothesis A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Background Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative air-bone gap remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative air-bone gap. Methods Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Results Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with prior literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable following electrode placement. Conclusion Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity. PMID:27579835
Potts, Lisa G; Skinner, Margaret W; Litovsky, Ruth A; Strube, Michael J; Kuk, Francis
2009-06-01
The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. One option for bilateral stimulation is the use of a cochlear implant in one ear and a hearing aid in the opposite nonimplanted ear (bimodal hearing). This study evaluated the effect of wearing a cochlear implant in one ear and a digital hearing aid in the opposite ear on speech recognition and localization. A repeated-measures correlational study was completed. Nineteen adult Cochlear Nucleus 24 implant recipients participated in the study. The participants were fit with a Widex Senso Vita 38 hearing aid to achieve maximum audibility and comfort within their dynamic range. Soundfield thresholds, loudness growth, speech recognition, localization, and subjective questionnaires were obtained six-eight weeks after the hearing aid fitting. Testing was completed in three conditions: hearing aid only, cochlear implant only, and cochlear implant and hearing aid (bimodal). All tests were repeated four weeks after the first test session. Repeated-measures analysis of variance was used to analyze the data. Significant effects were further examined using pairwise comparison of means or in the case of continuous moderators, regression analyses. The speech-recognition and localization tasks were unique, in that a speech stimulus presented from a variety of roaming azimuths (140 degree loudspeaker array) was used. Performance in the bimodal condition was significantly better for speech recognition and localization compared to the cochlear implant-only and hearing aid-only conditions. Performance was also different between these conditions when the location (i.e., side of the loudspeaker array that presented the word) was analyzed. In the bimodal condition, the speech-recognition and localization tasks were equal regardless of which side of the loudspeaker array presented the word, while performance was significantly poorer for the monaural conditions (hearing aid only and cochlear implant only) when the words were presented on the side with no stimulation. Binaural loudness summation of 1-3 dB was seen in soundfield thresholds and loudness growth in the bimodal condition. Measures of the audibility of sound with the hearing aid, including unaided thresholds, soundfield thresholds, and the Speech Intelligibility Index, were significant moderators of speech recognition and localization. Based on the questionnaire responses, participants showed a strong preference for bimodal stimulation. These findings suggest that a well-fit digital hearing aid worn in conjunction with a cochlear implant is beneficial to speech recognition and localization. The dynamic test procedures used in this study illustrate the importance of bilateral hearing for locating, identifying, and switching attention between multiple speakers. It is recommended that unilateral cochlear implant recipients, with measurable unaided hearing thresholds, be fit with a hearing aid.
ERIC Educational Resources Information Center
Ben-Itzhak, D.; Most, T.; Weisel, A.
2005-01-01
The present study examined the relationships between teachers' and communication clinicians' self-reported knowledge on cochlear implants and their expectations of CIs. The authors also explored these professionals' views regarding the child's communication mode, educational setting, and social options following cochlear implantation. The…
The Relationship between Cochlear Implants and Deaf Identity
ERIC Educational Resources Information Center
Chapman, Madeline; Dammeyer, Jesper
2017-01-01
The degree to which individuals with cochlear implants (CIs) experience communication difficulties has implications for social participation and identity development. However, few studies have examined the relationship between cochlear implantation, identity, and social participation. Using data from a Danish national survey of deaf adults, the…
Riggs, G H; Schweitzer, L
1994-01-01
Various studies have suggested that glycoconjugates may influence connectivity and lamination in the developing central nervous system and may function as barriers to neuritic extension. It has been proposed that the peanut agglutinin lectin labels a glycoconjugate subserving a barrier function. We chose to investigate the distribution of this peanut-agglutinin-labelled glycoconjugate in the dorsal cochlear nucleus of the developing hamster since the development of the dorsal cochlear nucleus is well characterised and its axons obey laminar boundaries. The distribution of peanut agglutinin label throughout the cochlear nucleus delineated zones that cochlear axons fail to invade. In the dorsal cochlear nucleus, laminar differences were reduced on postnatal d 13 and virtually disappearing by postnatal d 23. Label in the molecular layer dissipated as axons and dendrites grew into this layer. These patterns of peanut agglutinin binding correspond to axonal ingrowth and are consistent with a barrier function for glycoconjugates in the molecular layer. Images Fig. 1 Fig. 2 Fig. 4 PMID:7961144
Modulation of Mcl-1 expression reduces age-related cochlear degeneration
Yang, Wei Ping; Xu, Yang; Guo, Wei Wei; Liu, Hui Zhan; Hu, Bo Hua
2013-01-01
Mcl-1 is an anti-apoptotic member of the Bcl-2 family that modulates apoptosis-related signaling pathways and promotes cell survival. We have previously demonstrated a reduction of Mcl-1 expression in aging cochleae. To investigate whether restoring Mcl-1 expression would reduce aging-related cochlear degeneration, we developed a rat model of Mcl-1 overexpression. A plasmid encoding human Mcl-1/enhanced green fluorescent protein was applied to the round window of the cochlea. This in vivo treatment transfected both the sensory and supporting cells of the cochlear sensory epithelium and enhanced Mcl-1 expression at both the mRNA and the protein level. The upregulation of Mcl-1 expression reduced the progression of age-related cochlear dysfunction and sensory cell death. Furthermore, the transfection of Mcl-1 exerted its protective effect by suppressing cochlear apoptosis at the mitochondrial level. This study demonstrates that the genetic modulation of Mcl-1 expression reduces the progression of age-related cochlear degeneration. PMID:23790646
Gain and frequency tuning within the mouse cochlear apex
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oghalai, John S.; Raphael, Patrick D.; Gao, Simon
Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided bymore » basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.« less
Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T
2011-10-01
Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America
Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.
2011-01-01
Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363
Sudden Bilateral Sensorineural Hearing Loss Following Postpartum Hemorrhage: A Case Report
Mirzaeian, Sara; Ayati, Sedigheh; Maleki, Asieh
2017-01-01
The prevalence of bilateral sudden sensorineural hearing loss (SSNHL) is less than 5% and the etiology of most cases is unknown. Due to many structural and functional similarities between the kidney and inner ear, many conditions, diseases, and drugs have both renal and cochlear effects and toxicities. There are several reports of SSNHL in patients with CRF, uraemic patient, hemodialysis treatment, and ARF. Here, we report a rare manifestation of SSNHL following severe postpartum hemorrhage that has simultaneous renal failure and cochlear impairment. The patient was a 22-year-old primigravida woman with term pregnancy who after delivery and episiotomy hematoma and postpartum hemorrhage subsequently suffered from kidney failure, oliguria, and SSNHL that occurred after 3 days of delivery. In conditions such as severe postpartum bleeding leading to acute renal involvement, the possibility of simultaneous involvement of cochlea due to hypoxia or received drugs should be considered. PMID:28761208
International classification of reliability for implanted cochlear implant receiver stimulators.
Battmer, Rolf-Dieter; Backous, Douglas D; Balkany, Thomas J; Briggs, Robert J S; Gantz, Bruce J; van Hasselt, Andrew; Kim, Chong Sun; Kubo, Takeshi; Lenarz, Thomas; Pillsbury, Harold C; O'Donoghue, Gerard M
2010-10-01
To design an international standard to be used when reporting reliability of the implanted components of cochlear implant systems to appropriate governmental authorities, cochlear implant (CI) centers, and for journal editors in evaluating manuscripts involving cochlear implant reliability. The International Consensus Group for Cochlear Implant Reliability Reporting was assembled to unify ongoing efforts in the United States, Europe, Asia, and Australia to create a consistent and comprehensive classification system for the implanted components of CI systems across manufacturers. All members of the consensus group are from tertiary referral cochlear implant centers. None. A clinically relevant classification scheme adapted from principles of ISO standard 5841-2:2000 originally designed for reporting reliability of cardiac pacemakers, pulse generators, or leads. Standard definitions for device failure, survival time, clinical benefit, reduced clinical benefit, and specification were generated. Time intervals for reporting back to implant centers for devices tested to be "out of specification," categorization of explanted devices, the method of cumulative survival reporting, and content of reliability reports to be issued by manufacturers was agreed upon by all members. The methodology for calculating Cumulative survival was adapted from ISO standard 5841-2:2000. The International Consensus Group on Cochlear Implant Device Reliability Reporting recommends compliance to this new standard in reporting reliability of implanted CI components by all manufacturers of CIs and the adoption of this standard as a minimal reporting guideline for editors of journals publishing cochlear implant research results.
Dai, Chuanfu; Zhao, Zeqi; Zhang, Duo; Lei, Guanxiong
2018-01-01
Background The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. Material/Methods The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. Results Spectral ripple discrimination thresholds did not correlate with age (r=−0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). Conclusions In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China. PMID:29806954
Dai, Chuanfu; Zhao, Zeqi; Shen, Weidong; Zhang, Duo; Lei, Guanxiong; Qiao, Yuehua; Yang, Shiming
2018-05-28
BACKGROUND The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. MATERIAL AND METHODS The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. RESULTS Spectral ripple discrimination thresholds did not correlate with age (r=-0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). CONCLUSIONS In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China.
The Modified Rambo Transcanal Approach for Cochlear Implantation in CHARGE Syndrome.
Wick, Cameron C; Moore, Amy M; Killeen, Daniel E; Isaacson, Brandon
2017-10-01
CHARGE syndrome is associated with a variety of temporal bone anomalies and deafness. The lack of surgical landmarks and facial nerve irregularities make cochlear implantation in this population a challenging endeavor. This study aims to describe a safe and efficacious transcanal approach for cochlear implantation that obviates the need to perform a mastoidectomy and facial recess. Three children with profound hearing loss secondary to CHARGE syndrome. Transcanal cochlear implantation with closure of the ear canal via a modified Rambo meatoplasty. Retrospective chart review of temporal bone anomalies associated with CHARGE syndrome, technical nuances of this transcanal approach, and cochlear implant outcomes. The mean patient age was 2.5 years (range 1.5-3.8 yr). Two were male and two were left ears. All patients had a hypoplastic mastoid, semicircular canal aplasia, and had some degree of cochlear dysplasia. A full cochlear implant insertion was achieved in all cases, even in the presence of grossly abnormal middle ear and facial nerve anatomy. There were no intraoperative or postoperative complications. The mean follow-up was 12.4 months (range, 3.9-25.2 mo). All three patients use their device daily. Their guardians report improved vocalization and environmental awareness. The modified Rambo transcanal approach provides a safe corridor for cochlear implantation in patients with CHARGE syndrome. This approach minimizes the anatomical variations associated with the syndrome and may reduce the risk of electrode extrusion. Implant outcomes in this patient population remain highly variable based on the patient's global cognitive capacity.
Early Vocabulary Development in Children with Bilateral Cochlear Implants
ERIC Educational Resources Information Center
Välimaa, Taina; Kunnari, Sari; Laukkanen-Nevala, Päivi; Lonka, Eila
2018-01-01
Background: Children with unilateral cochlear implants (CIs) may have delayed vocabulary development for an extended period after implantation. Bilateral cochlear implantation is reported to be associated with improved sound localization and enhanced speech perception in noise. This study proposed that bilateral implantation might also promote…
Deafblind People's Experiences of Cochlear Implantation
ERIC Educational Resources Information Center
Soper, Janet
2006-01-01
Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…
The benefits of remote microphone technology for adults with cochlear implants.
Fitzpatrick, Elizabeth M; Séguin, Christiane; Schramm, David R; Armstrong, Shelly; Chénier, Josée
2009-10-01
Cochlear implantation has become a standard practice for adults with severe to profound hearing loss who demonstrate limited benefit from hearing aids. Despite the substantial auditory benefits provided by cochlear implants, many adults experience difficulty understanding speech in noisy environments and in other challenging listening conditions such as television. Remote microphone technology may provide some benefit in these situations; however, little is known about whether these systems are effective in improving speech understanding in difficult acoustic environments for this population. This study was undertaken with adult cochlear implant recipients to assess the potential benefits of remote microphone technology. The objectives were to examine the measurable and perceived benefit of remote microphone devices during television viewing and to assess the benefits of a frequency-modulated system for speech understanding in noise. Fifteen adult unilateral cochlear implant users were fit with remote microphone devices in a clinical environment. The study used a combination of direct measurements and patient perceptions to assess speech understanding with and without remote microphone technology. The direct measures involved a within-subject repeated-measures design. Direct measures of patients' speech understanding during television viewing were collected using their cochlear implant alone and with their implant device coupled to an assistive listening device. Questionnaires were administered to document patients' perceptions of benefits during the television-listening tasks. Speech recognition tests of open-set sentences in noise with and without remote microphone technology were also administered. Participants showed improved speech understanding for television listening when using remote microphone devices coupled to their cochlear implant compared with a cochlear implant alone. This benefit was documented both when listening to news and talk show recordings. Questionnaire results also showed statistically significant differences between listening with a cochlear implant alone and listening with a remote microphone device. Participants judged that remote microphone technology provided them with better comprehension, more confidence, and greater ease of listening. Use of a frequency-modulated system coupled to a cochlear implant also showed significant improvement over a cochlear implant alone for open-set sentence recognition in +10 and +5 dB signal to noise ratios. Benefits were measured during remote microphone use in focused-listening situations in a clinical setting, for both television viewing and speech understanding in noise in the audiometric sound suite. The results suggest that adult cochlear implant users should be counseled regarding the potential for enhanced speech understanding in difficult listening environments through the use of remote microphone technology.
Melodic contour identification by cochlear implant listeners.
Galvin, John J; Fu, Qian-Jie; Nogaki, Geraldine
2007-06-01
While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task could be used to quantify cochlear implant users' ability to recognize musical melodies and whether MCI performance could be improved with moderate auditory training. The present study also compared MCI performance with familiar melody identification (FMI) performance, with and without MCI training. For the MCI task, test stimuli were melodic contours composed of 5 notes of equal duration whose frequencies corresponded to musical intervals. The interval between successive notes in each contour was varied between 1 and 5 semitones; the "root note" of the contours was also varied (A3, A4, and A5). Nine distinct musical patterns were generated for each interval and root note condition, resulting in a total of 135 musical contours. The identification of these melodic contours was measured in 11 cochlear implant users. FMI was also evaluated in the same subjects; recognition of 12 familiar melodies was tested with and without rhythm cues. MCI was also trained in 6 subjects, using custom software and melodic contours presented in a different frequency range from that used for testing. Results showed that MCI recognition performance was highly variable among cochlear implant users, ranging from 14% to 91% correct. For most subjects, MCI performance improved as the number of semitones between successive notes was increased; performance was slightly lower for the A3 root note condition. Mean FMI performance was 58% correct when rhythm cues were preserved and 29% correct when rhythm cues were removed. Statistical analyses revealed no significant correlation between MCI performance and FMI performance (with or without rhythmic cues). However, MCI performance was significantly correlated with vowel recognition performance; FMI performance was not correlated with cochlear implant subjects' phoneme recognition performance. Preliminary results also showed that the MCI training improved all subjects' MCI performance; the improved MCI performance also generalized to improved FMI performance. Preliminary data indicate that the closed-set MCI task is a viable approach toward quantifying an important component of cochlear implant users' music perception. The improvement in MCI performance and generalization to FMI performance with training suggests that MCI training may be useful for improving cochlear implant users' music perception and appreciation; such training may be necessary to properly evaluate patient performance, as acute measures may underestimate the amount of musical information transmitted by the cochlear implant device and received by cochlear implant listeners.
Negotiating Reassurance: Parents' Narratives on Follow-Up after Cochlear Implantation
ERIC Educational Resources Information Center
Bruin, Marieke; Ohna, Stein Erik
2015-01-01
This study presents an analysis of parental experiences on follow-up after cochlear implantation. Data were constructed in semi-structured, individual interviews with the parents of 14 children who use cochlear implants. Drawing on narrative analysis, the study explores parental responses to insecurity concerning children's learning and…
Concept Learning and Heuristic Classification in Weak-Theory Domains
1990-03-01
age and noise-induced cochlear age..gt.60 noise-induced cochlear air(mild) age-induced cochlear history(noise) norma ]_ear speechpoor)acousticneuroma...Annual review of computer science. Machine Learning, 4, 1990. (to appear). [18] R.T. Duran . Concept learning with incomplete data sets. Master’s thesis
Challenges in Optimizing Oral Communication in Children with Cochlear Implants.
ERIC Educational Resources Information Center
Ertmer, David J.
2002-01-01
This article introduces a forum that provides information for assisting speech-language pathologists and audiologists in fulfilling their professional responsibilities in a variety of settings to children with hearing impairments who have cochlear implants. A preview of the following articles on services for children with cochlear implants is…
Agile Development of Advanced Prototypes
2014-11-01
prostheses: retinal implants, cochlear implants, and neuroprosthetics (EEG controlled artificial limbs); an interactive, virtual experience...demonstrations allowing users to experience, from a patient’s perspective life with three different prostheses: retinal implants, cochlear implants...three experiences were researched and developed. The applications are interactive demonstrations of retinal implants, cochlear implants, and
Voice emotion perception and production in cochlear implant users.
Jiam, N T; Caldwell, M; Deroche, M L; Chatterjee, M; Limb, C J
2017-09-01
Voice emotion is a fundamental component of human social interaction and social development. Unfortunately, cochlear implant users are often forced to interface with highly degraded prosodic cues as a result of device constraints in extraction, processing, and transmission. As such, individuals with cochlear implants frequently demonstrate significant difficulty in recognizing voice emotions in comparison to their normal hearing counterparts. Cochlear implant-mediated perception and production of voice emotion is an important but relatively understudied area of research. However, a rich understanding of the voice emotion auditory processing offers opportunities to improve upon CI biomedical design and to develop training programs benefiting CI performance. In this review, we will address the issues, current literature, and future directions for improved voice emotion processing in cochlear implant users. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluating cochlear implant trauma to the scala vestibuli.
Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W
2005-04-01
Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.
Cochlear implantation for single-sided deafness and tinnitus suppression.
Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George
To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.
Greaver, Laura; Eskridge, Hannah; Teagle, Holly F B
2017-06-13
The purpose of this clinical report is to present case studies of children who are nontraditional candidates for cochlear implantation because they have significant residual hearing in 1 ear and to describe outcomes and considerations for their audiological management and habilitation. Case information is presented for 5 children with profound hearing loss in 1 ear and normal or mild-to-moderate hearing loss in the opposite ear and who have undergone unilateral cochlear implantation. Pre- and postoperative assessments were performed per typical clinic routines with modifications described. Postimplant habilitation was customized for each recipient using a combination of traditional methods, newer technologies, and commercial materials. The 5 children included in this report are consistent users of their cochlear implants and demonstrate speech recognition in the implanted ear when isolated from the better hearing ear. Candidacy criteria for cochlear implantation are evolving. Children with single-sided deafness or asymmetric hearing loss who have traditionally not been considered candidates for cochlear implantation should be evaluated on a case-by-case basis. Audiological management of these recipients is not vastly different compared with children who are traditional cochlear implant recipients. Assessment and habilitation techniques must be modified to isolate the implanted ear to obtain accurate results and to provide meaningful therapeutic intervention.
Spatiotemporal expression of Ezh2 in the developing mouse cochlear sensory epithelium.
Chen, Yan; Li, Wenyan; Li, Wen; Chai, Renjie; Li, Huawei
2016-09-01
The enhancer of zeste 2 polycomb repressive complex 2 subunit (Ezh2) is a histone-lysine Nmethyltransferase enzyme that participates in DNA methylation. Ezh2 has also been reported to play crucial roles in stem cell proliferation and differentiation. However, the detailed expression profile of Ezh2 during mouse cochlear development has not been investigated. Here, we examined the spatiotemporal expression of Ezh2 in the cochlea during embryonic and postnatal development. Ezh2 expression began to be observed in the whole otocyst nuclei at embryonic day 9.5 (E9.5). At E12.5, Ezh2 was expressed in the nuclei of the cochlear prosensory epithelium. At E13.5 and E15.5, Ezh2 was expressed from the apical to the basal turns in the nuclei of the differentiating cochlear epithelium. At postnatal day (P) 0 and 7, the Ezh2 expression was located in the nuclei of the cochlear epithelium in all three turns and could be clearly seen in outer and inner hair cells, supporting cells, the stria vascularis, and spiral ganglion cells. Ezh2 continued to be expressed in the cochlear epithelium of adult mice. Our results provide the basic Ezh2 expression pattern and might be useful for further investigating the detailed role of Ezh2 during cochlear development.
Chertoff, Mark E.; Earl, Brian R.; Diaz, Francisco J.; Sorensen, Janna L.; Thomas, Megan L. A.; Kamerer, Aryn M.; Peppi, Marcello
2014-01-01
The electrical signal recorded at the round window was used to estimate the location of missing outer hair cells. The cochlear response was recorded to a low frequency tone embedded in high-pass filtered noise conditions. Cochlear damage was created by either overexposure to frequency-specific tones or laser light. In animals with continuous damage along the partition, the amplitude of the cochlear response increased as the high-pass cutoff frequency increased, eventually reaching a plateau. The cochlear distance at the onset of the plateau correlated with the anatomical onset of outer hair cell loss. A mathematical model replicated the physiologic data but was limited to cases with continuous hair cell loss in the middle and basal turns. The neural contribution to the cochlear response was determined by recording the response before and after application of Ouabain. Application of Ouabain eliminated or reduced auditory neural activity from approximately two turns of the cochlea. The amplitude of the cochlear response was reduced for moderate signal levels with a limited effect at higher levels, indicating that the cochlear response was dominated by outer hair cell currents at high signal levels and neural potentials at low to moderate signal levels. PMID:25190395
Teissier, N; Doehring, I; Noel-Petroff, N; Elmaleh-Bergès, M; Viala, P; François, M; Faye, A; Van Den Abbeele, T; Lorrot, M
2013-06-01
Bacterial meningitis (BM) is the primary etiology of acquired sensorineural hearing loss (SNHL) in children and may compromise language development. Since the 1990 s, cochlear implants (CIs) have become part of the management of children with profound SNHL with encouraging results. The aim of this study was to analyze the audiophonological performance of children before and after cochlear implantation for SNHL following bacterial meningitis. Retrospective study of all children fitted with CIs for bilateral severe to profound SNHL after bacterial meningitis in the Robert-Debré pediatric ENT department between August 1990 and March 2009. Audiophonological performance was assessed using the APCEI profile. Of the 283 children receiving implants during that period, 16 children (6%; 6 boys, 10 girls) underwent CI implantation after bacterial meningitis (Streptococcus pneumoniae in 8 cases, Neisseria meningitidis in 2 cases, and Haemophilus influenzae in 4 cases). The mean time from meningitis to SNHL was 8.3 months (median, 1.5 months; range, 1 day to 13 years). The mean time from meningitis to cochlear implantation was 2 years and 3 months (median, 7 months; range, 1 month to 13 years 3 months). Twelve children (75%) presented partial cochlear and/or vestibular ossification on presurgical CT scan. Three children received bilateral implants. Thirteen children (81%) developed early SNHL in the first 3 months, whereas 3 children developed SNHL more than 10 months after meningitis. As for the benefits of cochlear implantation, 11 children presented near to normal intelligibility and optimal use of their cochlear implant; 5 children presented partial benefits due to neurological sequelae (1), a long delay before implantation (1), technical problems (2), or a social problem in relation to low socioeconomic status (1). After bacterial meningitis, audiological evaluation must be made carefully during the first 3 months to detect early SNHL, but SNHL may also develop several years later. In case of profound SNHL and a modified signal of the labyrinth on the MRI, cochlear implantation must be performed without delay before cochlear and/or vestibular ossification. Cochlear implantation is an effective technique with good long-term audiologic results. The coexistence of neurological lesions may compromise the results, but it should not contraindicate a cochlear implantation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Meyer, Ted A; Frisch, Stefan A; Pisoni, David B; Miyamoto, Richard T; Svirsky, Mario A
2003-07-01
Do cochlear implants provide enough information to allow adult cochlear implant users to understand words in ways that are similar to listeners with acoustic hearing? Can we use a computational model to gain insight into the underlying mechanisms used by cochlear implant users to recognize spoken words? The Neighborhood Activation Model has been shown to be a reasonable model of word recognition for listeners with normal hearing. The Neighborhood Activation Model assumes that words are recognized in relation to other similar-sounding words in a listener's lexicon. The probability of correctly identifying a word is based on the phoneme perception probabilities from a listener's closed-set consonant and vowel confusion matrices modified by the relative frequency of occurrence of the target word compared with similar-sounding words (neighbors). Common words with few similar-sounding neighbors are more likely to be selected as responses than less common words with many similar-sounding neighbors. Recent studies have shown that several of the assumptions of the Neighborhood Activation Model also hold true for cochlear implant users. Closed-set consonant and vowel confusion matrices were obtained from 26 postlingually deafened adults who use cochlear implants. Confusion matrices were used to represent input errors to the Neighborhood Activation Model. Responses to the different stimuli were then generated by the Neighborhood Activation Model after incorporating the frequency of occurrence counts of the stimuli and their neighbors. Model outputs were compared with obtained performance measures on the Consonant-Vowel Nucleus-Consonant word test. Information transmission analysis was used to assess whether the Neighborhood Activation Model was able to successfully generate and predict word and individual phoneme recognition by cochlear implant users. The Neighborhood Activation Model predicted Consonant-Vowel Nucleus-Consonant test words at levels similar to those correctly identified by the cochlear implant users. The Neighborhood Activation Model also predicted phoneme feature information well. The results obtained suggest that the Neighborhood Activation Model provides a reasonable explanation of word recognition by postlingually deafened adults after cochlear implantation. It appears that multichannel cochlear implants give cochlear implant users access to their mental lexicons in a manner that is similar to listeners with acoustic hearing. The lexical properties of the test stimuli used to assess performance are important to spoken-word recognition and should be included in further models of the word recognition process.
Potts, Lisa G.; Skinner, Margaret W.; Litovsky, Ruth A.; Strube, Michael J; Kuk, Francis
2010-01-01
Background The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. One option for bilateral stimulation is the use of a cochlear implant in one ear and a hearing aid in the opposite nonimplanted ear (bimodal hearing). Purpose This study evaluated the effect of wearing a cochlear implant in one ear and a digital hearing aid in the opposite ear on speech recognition and localization. Research Design A repeated-measures correlational study was completed. Study Sample Nineteen adult Cochlear Nucleus 24 implant recipients participated in the study. Intervention The participants were fit with a Widex Senso Vita 38 hearing aid to achieve maximum audibility and comfort within their dynamic range. Data Collection and Analysis Soundfield thresholds, loudness growth, speech recognition, localization, and subjective questionnaires were obtained six–eight weeks after the hearing aid fitting. Testing was completed in three conditions: hearing aid only, cochlear implant only, and cochlear implant and hearing aid (bimodal). All tests were repeated four weeks after the first test session. Repeated-measures analysis of variance was used to analyze the data. Significant effects were further examined using pairwise comparison of means or in the case of continuous moderators, regression analyses. The speech-recognition and localization tasks were unique, in that a speech stimulus presented from a variety of roaming azimuths (140 degree loudspeaker array) was used. Results Performance in the bimodal condition was significantly better for speech recognition and localization compared to the cochlear implant–only and hearing aid–only conditions. Performance was also different between these conditions when the location (i.e., side of the loudspeaker array that presented the word) was analyzed. In the bimodal condition, the speech-recognition and localization tasks were equal regardless of which side of the loudspeaker array presented the word, while performance was significantly poorer for the monaural conditions (hearing aid only and cochlear implant only) when the words were presented on the side with no stimulation. Binaural loudness summation of 1–3 dB was seen in soundfield thresholds and loudness growth in the bimodal condition. Measures of the audibility of sound with the hearing aid, including unaided thresholds, soundfield thresholds, and the Speech Intelligibility Index, were significant moderators of speech recognition and localization. Based on the questionnaire responses, participants showed a strong preference for bimodal stimulation. Conclusions These findings suggest that a well-fit digital hearing aid worn in conjunction with a cochlear implant is beneficial to speech recognition and localization. The dynamic test procedures used in this study illustrate the importance of bilateral hearing for locating, identifying, and switching attention between multiple speakers. It is recommended that unilateral cochlear implant recipients, with measurable unaided hearing thresholds, be fit with a hearing aid. PMID:19594084
Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi
2018-05-18
OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.
Bush, Matthew L.; Burton, Mary; Loan, Ashley; Shinn, Jennifer B.
2013-01-01
Objective The purpose of this study was to examine the timing of early intervention diagnostic and therapeutic services in cochlear implant recipients from rural and urban areas. Study design Retrospective case series review Setting Tertiary referral center Patients Cochlear implant recipients from a single comprehensive hearing institute born with severe congenital sensorineural hearing loss were examined. Timing of diagnostic and therapeutic services was examined. Intervention(s) Diagnosis, amplification, and eventual cochlear implantation for all patients in the study Main outcome measure(s) Time points of definitive diagnosis, amplification, and cochlear implantation for children from urban and rural regions were examined. Correlation analysis of distance to testing center and timing of services was also assessed. Results 40 children born with congenital hearing loss were included in the study and were diagnosed at a median age of 13 weeks after birth. Children from rural regions obtained amplification at a median age of 47.7 weeks after birth, while urban children were amplified at 26 weeks after birth. Cochlear implantation was performed at a median age of 182 weeks after birth in those from rural areas and at 104 weeks after birth in urban-dwelling patients. A linear relationship was identified between distance to the implant center and timing of hearing aid amplification (r=0.5, p=0.033) and cochlear implantation (r=0.5, p=0.016). Conclusions Children residing outside of metro areas may be at higher risk of delayed rehabilitative services and cochlear implantation than those residing in urban areas that may be closer in proximity to tertiary care centers. PMID:24136305
Graham, Christine E.; Basappa, Johnvesly; Turcan, Sevin; Vetter, Douglas E.
2011-01-01
A key requirement for encoding the auditory environment is the ability to dynamically alter cochlear sensitivity. However, merely attaining a steady state of maximal sensitivity is not a viable solution since the sensory cells and ganglion cells of the cochlea are prone to damage following exposure to loud sound. Most often, such damage is via initial metabolic insult that can lead to cellular death. Thus, establishing the highest sensitivity must be balanced with protection against cellular metabolic damage that can lead to loss of hair cells and ganglion cells, resulting in loss of frequency representation. While feedback mechanisms are known to exist in the cochlea that alter sensitivity, they respond only after stimulus encoding, allowing potentially damaging sounds to impact the inner ear at times coincident with increased sensitivity. Thus, questions remain concerning the endogenous signaling systems involved in dynamic modulation of cochlear sensitivity and protection against metabolic stress. Understanding endogenous signaling systems involved in cochlear protection may lead to new strategies and therapies for prevention of cochlear damage and consequent hearing loss. We have recently discovered a novel cochlear signaling system that is molecularly equivalent to the classic hypothalamic-pituitary-adrenal (HPA) axis. This cochlear HPA-equivalent system functions to balance auditory sensitivity and susceptibility to noise-induced hearing loss, and also protects against cellular metabolic insults resulting from exposures to ototoxic drugs. We review the anatomy, physiology, and cellular signaling of this system, and compare it to similar signaling in other organs/tissues of the body. PMID:21909974
Morawski, Krzysztof; Telischi, Fred F; Bohorquez, Jorge; Niemczyk, Kazimierz
2009-09-01
Local application of dexamethasone to the round window (RW) niche prevents cochlear damage caused by local reversible ischemia. Cochlear ischemia induced by internal auditory artery (IAA) compression/stretching is thought to cause postoperative sensory hearing loss after attempted hearing preservation removal of acoustic neuroma tumors. Dexamethasone administered to the RW niche traveling through the membrane to the cochlear fluids may prevent ischemic damage. Ten young albino rabbits were used for this study. Ischemic episodes were induced by compressing the IAA. Laser Doppler cochlear blood flow was measured using a probe positioned at the RW niche. Transtympanic electrocochleography was measured at 4, 8, and 12 kHz. In 5 test ears, dexamethasone was administered topically at the RW for approximately 50 minutes before the IAA compressions, whereas in 5 control ears, saline was applied in the same way. Each ear underwent one 10-minute IAA compression with a 60-minute postischemic period of transtympanic electrocochleography monitoring. In both control- and dexamethasone-treated ears, ischemic episodes measured by Laser Doppler cochlear blood flow were comparable. Fifty minutes after IAA decompression, in dexamethasone-pretreated ears, cochlear microphonic and compound action potential amplitudes at all test frequencies were 10 to 15% less reduced than those in control ears. Compound action potential latencies in dexamethasone-pretreated ears resulted in shorter latency delay than in control ears. The RW seems to be an efficacious route for the administration of dexamethasone into the inner ear. Dexamethasone showed a protective effect on cochlear function after local ischemia. Transtympanic electrocochleography was found to be a sufficient and effective tool in monitoring hearing.
Quality-of-life benefit from cochlear implantation in the elderly.
Vermeire, Katrien; Brokx, Jan P L; Wuyts, Floris L; Cochet, Ellen; Hofkens, Anouk; Van de Heyning, Paul H
2005-03-01
To compare the audiologic results of geriatric patients receiving cochlear implants with younger age groups and to evaluate the quality of life after cochlear implantation in the geriatric population by means of validated quality-of-life questionnaires. Cross-sectional study involving 89 postlingually deafened cochlear implant subjects. Tertiary referral center. A total of 89 postlingually deafened patients were included in the study, among which were 25 patients who were aged 70 years or older. All patients received a cochlear implant. Subjects were implanted with either the Laura, Nucleus 24, or Med-el Combi 40+ cochlear implant systems implementing the SPEAK, ACE, CIS, or CIS+ coding strategies. Speech recognition was determined by means of phonetically balanced monosyllabic word lists. The Hearing Handicap Inventory for Adults, the Glasgow Benefit Inventory, and the scale for the prediction of hearing disability in sensorineural hearing loss were used to quantify the quality of life. Mean audiologic performance for the three groups increased significantly after implantation (p < 0.001). Postoperative audiologic performance of the geriatric population led to useful hearing, but these scores were significantly lower than for the younger age groups (p = 0.002). However, the quality-of-life outcomes for the geriatric group were similar to those of the younger age groups (p = 0.411 for the Hearing Handicap Inventory for Adults; p = 0.886 for the Glasgow Benefit Inventory). The results of this study prove that cochlear implantation in the elderly provides improvements in quality of life and speech understanding, similar to those for younger adult cochlear implant recipients.
Vecchiato, G; Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Di Francesco, G; Vitiello, S; Colosimo, A; Babiloni, Fabio
2012-01-01
Interestingly, the international debate about the quality of music fruition for cochlear implanted users does not take into account the hypothesis that bilateral users could perceive music in a more pleasant way with respect to monolateral users. In this scenario, the aim of the present study was to investigate if cerebral signs of pleasantness during music perception in healthy child are similar to those observed in monolateral and in bilateral cochlear implanted users. In fact, previous observations in literature on healthy subjects have indicated that variations of the frontal EEG alpha activity are correlated with the perceived pleasantness of the sensory stimulation received (approach-withdrawal theory). In particular, here we described differences between cortical activities estimated in the alpha frequency band for a healthy child and in patients having a monolateral or a bilateral cochlear implant during the fruition of a musical cartoon. The results of the present analysis showed that the alpha EEG asymmetry patterns observed in a healthy child and that of a bilateral cochlear implanted patient are congruent with the approach-withdrawal theory. Conversely, the scalp topographic distribution of EEG power spectra in the alpha band resulting from the monolateral cochlear user presents a different EEG pattern from the normal and bilateral implanted patients. Such differences could be explained at the light of the approach-withdrawal theory. In fact, the present findings support the hypothesis that a monolateral cochlear implanted user could perceive the music in a less pleasant way when compared to a healthy subject or to a bilateral cochlear user.
Goh, Terence; Bird, Philip; Pearson, John; Mustard, Jill
2016-01-01
The purpose of this study is to observe the education and vocational achievements and social participation of cochlear implant recipients as they graduate from a paediatric cochlear implant programme and identify any significant associations that might exist. This study identified 56 patients from the Southern Cochlear Implant Programme (SCIP) who received cochlear implants before the age of 19 (paediatric) and are now over the age of 19 (adult). A questionnaire investigated their education, employment, and identity with the hearing and deaf communities. Also included were the satisfaction with life scale and Hearing Participation Scale (HPS). Subjects ranged in age from 19 to 32. Twenty-six patients responded to the questionnaire, including one non-user. Twenty identified strongly or very strongly with the hearing community. There was weak evidence of a linear association between strong identity with the hearing community and a higher HPS score. No other statistically significant associations were detected. Interestingly, 12 out of 26 participants found employment through family. Positive outcome trends in education and employment were seen in this study although no statistical significance was achieved. There is a strong bias for those who use their cochlear implants regularly, and there are no data available for those who do not use their cochlear implants for comparison as only one non-user completed the survey, despite efforts to include this group. This study shows that there is perceived benefit in implantation for patients who use it regularly but further research is needed with a more diverse group of cochlear implant recipients.
Pediatric Cochlear Implants: An Overview of the Alternatives in Education and Rehabilitation.
ERIC Educational Resources Information Center
Barnes, Judith M., Ed.; And Others
This collection of 10 papers is intended as a resource book integrating information on pediatric cochlear implants for educators, parents, implant teams, and rehabilitation specialists. The papers focus on the importance of providing an oral educational environment to maximize cochlear implant success. An introduction notes controversies in the…
Realization of Complex Onsets by Pediatric Users of Cochlear Implants
ERIC Educational Resources Information Center
Chin, Steven B.
2006-01-01
This study examined variations in English complex onset realizations by children who use cochlear implants. Data consisted of 227 productions of two-segment onset clusters from 12 children. In general, onset cluster realizations of children with cochlear implants did not differ markedly from those reported for children with normal hearing: null…
ERIC Educational Resources Information Center
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose: To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and postimplant language development and executive function. Method: Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (Family Environment Scale-Fourth…
Taxonomic Knowledge of Children with and without Cochlear Implants
ERIC Educational Resources Information Center
Lund, Emily; Dinsmoor, Jessica
2016-01-01
Purpose: The purpose of this study was to compare the taxonomic vocabulary knowledge and organization of children with cochlear implants to (a) children with normal hearing matched for age, and (b) children matched for vocabulary development. Method: Ten children with cochlear implants, 10 age-matched children with normal hearing, and 10…
Children with Cochlear Implants in Australia: Educational Settings, Supports, and Outcomes
ERIC Educational Resources Information Center
Punch, Renee; Hyde, Merv
2010-01-01
This Australian study examined the communication, academic, and social outcomes of pediatric cochlear implantation from the perspectives of teachers working with children with cochlear implants. The children were aged from 1 to 18 years and attended a range of educational settings in early intervention, primary, and secondary schooling. One…
Cochlear Implants in Children with Hearing Loss: Maternal Expectations and Impact on the Family
ERIC Educational Resources Information Center
Zaidman-Zait, Anat; Most, Tova
2005-01-01
To facilitate evaluations of cochlear implant candidates and to promote (re)habilitation efficacy and collaboration with families, this study examined the expectations of 35 mothers with typical hearing and their beliefs and difficulties related to their child's hearing loss and current or future cochlear implantation. Questionnaires measured…
ERIC Educational Resources Information Center
Geers, Ann E.; Nicholas, Johanna; Tobey, Emily; Davidson, Lisa
2016-01-01
Purpose: The purpose of the present investigation is to differentiate children using cochlear implants (CIs) who did or did not achieve age-appropriate language scores by mid-elementary grades and to identify risk factors for persistent language delay following early cochlear implantation. Materials and Method: Children receiving unilateral CIs at…
Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet
ERIC Educational Resources Information Center
Searls, J. Matt, Comp.
2010-01-01
Cochlear implants (CIs) are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of individuals with significant permanent hearing loss. Cochlear implants may not be suitable for everyone. They are designed to provide…
Verbal Working Memory in Children with Cochlear Implants
ERIC Educational Resources Information Center
Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.
2017-01-01
Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…
Emotion Understanding in Deaf Children with a Cochlear Implant
ERIC Educational Resources Information Center
Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.
2013-01-01
It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…
Evaluating the Feasibility of Using Remote Technology for Cochlear Implants
ERIC Educational Resources Information Center
Goehring, Jenny L.; Hughes, Michelle L.; Baudhuin, Jacquelyn L.
2012-01-01
The use of remote technology to provide cochlear implant services has gained popularity in recent years. This article contains a review of research evaluating the feasibility of remote service delivery for recipients of cochlear implants. To date, published studies have determined that speech-processor programming levels and other objective tests…
Scala tympani cochleostomy I: results of a survey.
Adunka, Oliver F; Buchman, Craig A
2007-12-01
To assess current surgical techniques for scala tympani cochlear implantation among North American surgeons. A survey was distributed to all cochlear implant surgeons participating in the 2006 William House Cochlear Implant Study Group in Toronto, Canada. Participants were asked to anonymously identify their routine surgical practices. Images of trans-facial recess approaches to the round window and cochlear promontory were used in a multiple-choice fashion to assess the surgeon's typical exposure and cochleostomy location. Returned questionnaires were electronically processed and evaluated. Fifty-five (75%) of 73 returned surveys had adequate data validity and availability. Landmark identification and preferred cochleostomy locations varied greatly. About 20% of surgeons selected cochleostomy locations superior to the round window membrane. Cochleostomy size and location appeared to be influenced by surgical experience and whether or not the round window overhang was drilled off. This survey clearly documents marked variations in surgical techniques for scala tympani cochlear implantation. Future studies should more clearly define the surgical anatomy of this region for appropriate placement of a scala tympani cochleostomy. These findings may ultimately have an impact on hearing and neural preservation cochlear implant surgeries.
Amraei, K; Amirsalari, S; Ajalloueyan, M
2017-01-01
Hearing impairment is a common type of sensory loss in children. Studies indicate that children with hearing impairment are deficient in social, cognitive and communication skills. This study compared the intelligence quotients of first- and second-generation deaf children with cochlear implants. This research is causal-comparative. All 15 deaf children investigated had deaf parents and were selected from Baqiyatallah Cochlear Implant Center. The 15 children with cochlear implants were paired with similar children with hearing parents using purposive sampling. The findings show that the Hotelling trace of multivariate analysis of variance (F = 6.78, p < 0.01, η P 2 = 0.73) was significant. The tests of between-subjects effects for second-generation children was significantly higher than for first-generation children for all intelligence scales except knowledge. It can be assumed that second-generation children joined their family in the use of sign language as the primary experience before a cochlear implant. The use of sign language before cochlear implants is recommended. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Music activities and responses of young cochlear implant recipients.
van Besouw, Rachel M; Grasmeder, Mary L; Hamilton, Mary E; Baumann, Sarah E
2011-05-01
The development of auditory receptive skills and spoken language is often delayed in children who use cochlear implants, which may affect their appreciation of and responses to music. This in turn may be interpreted as disinterest in music. A questionnaire was developed to determine whether differences in exposure and responses to music exist between young cochlear implant recipients and their normally hearing peers. The questionnaire was developed by a multidisciplinary team and distributed to parents of preschool children with normal hearing and to parents of preschool children who had been implanted at least one year prior. The cochlear implant group comprised 23 children and was gender and age matched (within ±2 months) to a group of children with normal hearing. Young cochlear implant recipients receive similar exposure to audiovisual music media, parental singing and musical instruments at home. However, the data suggest that they receive less exposure to children's music presented without visual stimuli. Parents also reported less sophisticated responses to music for this group. The findings of this study have important implications concerning the provision of age-appropriate music habilitation materials and activities for young cochlear implant recipients.
Monstrey, Jolijn; Deeks, John M.; Macherey, Olivier
2014-01-01
Objective To evaluate a speech-processing strategy in which the lowest frequency channel is conveyed using an asymmetric pulse shape and “phantom stimulation”, where current is injected into one intra-cochlear electrode and where the return current is shared between an intra-cochlear and an extra-cochlear electrode. This strategy is expected to provide more selective excitation of the cochlear apex, compared to a standard strategy where the lowest-frequency channel is conveyed by symmetric pulses in monopolar mode. In both strategies all other channels were conveyed by monopolar stimulation. Design Within-subjects comparison between the two strategies. Four experiments: (1) discrimination between the strategies, controlling for loudness differences, (2) consonant identification, (3) recognition of lowpass-filtered sentences in quiet, (4) sentence recognition in the presence of a competing speaker. Study sample Eight users of the Advanced Bionics CII/Hi-Res 90k cochlear implant. Results Listeners could easily discriminate between the two strategies but no consistent differences in performance were observed. Conclusions The proposed method does not improve speech perception, at least in the short term. PMID:25358027
Carlyon, Robert P; Monstrey, Jolijn; Deeks, John M; Macherey, Olivier
2014-12-01
To evaluate a speech-processing strategy in which the lowest frequency channel is conveyed using an asymmetric pulse shape and "phantom stimulation", where current is injected into one intra-cochlear electrode and where the return current is shared between an intra-cochlear and an extra-cochlear electrode. This strategy is expected to provide more selective excitation of the cochlear apex, compared to a standard strategy where the lowest-frequency channel is conveyed by symmetric pulses in monopolar mode. In both strategies all other channels were conveyed by monopolar stimulation. Within-subjects comparison between the two strategies. Four experiments: (1) discrimination between the strategies, controlling for loudness differences, (2) consonant identification, (3) recognition of lowpass-filtered sentences in quiet, (4) sentence recognition in the presence of a competing speaker. Eight users of the Advanced Bionics CII/Hi-Res 90k cochlear implant. Listeners could easily discriminate between the two strategies but no consistent differences in performance were observed. The proposed method does not improve speech perception, at least in the short term.
Xiong, Hao; Pang, Jiaqi; Yang, Haidi; Dai, Min; Liu, Yimin; Ou, Yongkang; Huang, Qiuhong; Chen, Suijun; Zhang, Zhigang; Xu, Yaodong; Lai, Lan; Zheng, Yiqing
2015-04-01
The molecular mechanisms underlying age-related hearing loss are not fully understood, and currently, there is no treatment for this disorder. MicroRNAs have recently been reported to be increasingly associated with age-related diseases and are emerging as promising therapeutic targets. In this study, miR-34a/Sirtuin 1 (SIRT1)/p53 signaling was examined in cochlear hair cells during aging. MiR-34a, p53 acetylation, and apoptosis increased in the cochlea of C57BL/6 mice with aging, whereas an age-related decrease in SIRT1 was observed. In the inner ear HEI-OC1 cell line, miR-34a overexpression inhibited SIRT1, leading to an increase in p53 acetylation and apoptosis. Moreover, miR-34a knockdown increased SIRT1 expression and diminished p53 acetylation, and apoptosis. Additionally, resveratrol, an activator of SIRT1, significantly rescued miR-34a overexpression-induced HEI-OC1 cell death and significantly reduced hearing threshold shifts and hair cell loss in C57BL/6 mice after a 2-month administration. Our results support a link between age-related cochlear hair cell apoptosis and miR-34a/SIRT1/p53 signaling, which may serve as a potential target for age-related hearing loss treatment. Copyright © 2015 Elsevier Inc. All rights reserved.
Brain Network Regional Synchrony Analysis in Deafness
Xu, Lei; Liang, Mao-Jin
2018-01-01
Deafness, the most common auditory disease, has greatly affected people for a long time. The major treatment for deafness is cochlear implantation (CI). However, till today, there is still a lack of objective and precise indicator serving as evaluation of the effectiveness of the cochlear implantation. The goal of this EEG-based study is to effectively distinguish CI children from those prelingual deafened children without cochlear implantation. The proposed method is based on the functional connectivity analysis, which focuses on the brain network regional synchrony. Specifically, we compute the functional connectivity between each channel pair first. Then, we quantify the brain network synchrony among regions of interests (ROIs), where both intraregional synchrony and interregional synchrony are computed. And finally the synchrony values are concatenated to form the feature vector for the SVM classifier. What is more, we develop a new ROI partition method of 128-channel EEG recording system. That is, both the existing ROI partition method and the proposed ROI partition method are used in the experiments. Compared with the existing EEG signal classification methods, our proposed method has achieved significant improvements as large as 87.20% and 86.30% when the existing ROI partition method and the proposed ROI partition method are used, respectively. It further demonstrates that the new ROI partition method is comparable to the existing ROI partition method. PMID:29854776
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipsey, Ian
In his talk, Shipsey will discuss the cochlear implant, the first device to successfully allow the profoundly deaf to regain some sense of hearing. A cochlear implant is a small electronic apparatus. Unlike a normal hearing aid, which amplifies sound, a cochlear implant is surgically implanted behind the ear where it converts sound waves into electrical impulses. These implants have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. Shipsey will discuss the physiology of natural hearing from the perspective of a physicist. He willmore » also touch on the function of cochlear implants in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. Finally, Shipsey will address the social implications of cochlear implantation and the future outlook for auditory prostheses.« less
Liu, Yuying; Dong, Ruijuan; Li, Yuling; Xu, Tianqiu; Li, Yongxin; Chen, Xueqing; Gong, Shusheng
2014-12-01
To evaluate the auditory and speech abilities in children with auditory neuropathy spectrum disorder (ANSD) after cochlear implantation (CI) and determine the role of age at implantation. Ten children participated in this retrospective case series study. All children had evidence of ANSD. All subjects had no cochlear nerve deficiency on magnetic resonance imaging and had used the cochlear implants for a period of 12-84 months. We divided our children into two groups: children who underwent implantation before 24 months of age and children who underwent implantation after 24 months of age. Their auditory and speech abilities were evaluated using the following: behavioral audiometry, the Categories of Auditory Performance (CAP), the Meaningful Auditory Integration Scale (MAIS), the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), the Standard-Chinese version of the Monosyllabic Lexical Neighborhood Test (LNT), the Multisyllabic Lexical Neighborhood Test (MLNT), the Speech Intelligibility Rating (SIR) and the Meaningful Use of Speech Scale (MUSS). All children showed progress in their auditory and language abilities. The 4-frequency average hearing level (HL) (500Hz, 1000Hz, 2000Hz and 4000Hz) of aided hearing thresholds ranged from 17.5 to 57.5dB HL. All children developed time-related auditory perception and speech skills. Scores of children with ANSD who received cochlear implants before 24 months tended to be better than those of children who received cochlear implants after 24 months. Seven children completed the Mandarin Lexical Neighborhood Test. Approximately half of the children showed improved open-set speech recognition. Cochlear implantation is helpful for children with ANSD and may be a good optional treatment for many ANSD children. In addition, children with ANSD fitted with cochlear implants before 24 months tended to acquire auditory and speech skills better than children fitted with cochlear implants after 24 months. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.
Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko
2017-01-01
There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total suppression of tinnitus compared with their unilateral situation. While bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent) tinnitus was also reported. Dutch Trial Register NTR1722.
Tian, Yanjing; Zhou, Huifang; Zhang, Jing; Yang, Dong; Xu, Yi; Guo, Yuxi
2012-10-01
To compare the effect of rehabilitation of prelingual deaf children who used a cochlear implant (CI) in one ear and a hearing aids in the opposite ear while the hearing level of the opposite ears are different. Hearing ability, language ability and learning ability was included in the content. The aim of this research is to investigate better style of rehabilitation, and to offer the best help to the prelingual deaf children. Accord ing to the hearing level of the ear opposite to the one wearing a cochlear implant and whether the opposite ear wear a hearing aid or not, 30 prelingual deaf children were divided into three groups, including cochlear implant with opposite severe hearing loss and hearing aid ear (CI+SHA), cochlear implant with opposite profound hearing loss and hearing aid ear (CI+PHA), cochlear implant only (CI). The effect of rehabilitation was assessed in six different times (3,6,9,12,15 and 18 months after the cochlear implants and hearing aids began to work). The longer time the rehabilitation spends, the better the hearing ability,language ability and the learning ability were. The hearing ability of CI+SHA was better than those of CI+PHA (P<0.05) and CI (P<0.05). The language ability and learning ability of CI-SHA was nearly equal to those of the other two groups. The prelingual deaf children should take much more time on rehabilitation. The effect of rehabilitation for prelingual deaf children who used cochlear implant in one ear and hearing aid in the other depend on the residual hearing level of the other ear. If a prelingual deaf children still has any residual hearing level in the ear opposite to the cochlear implant ear, it is better for him/her to wear a hearing aid in the ear.
Heeringa, Amarins N.; Stefanescu, Roxana A.; Raphael, Yehoash; Shore, Susan E.
2015-01-01
Vesicular glutamate transporters 1 and 2 (VGLUT1 and VGLUT2) have distinct distributions in the cochlear nucleus that correspond to the sources of the labeled terminals. VGLUT1 is mainly associated with terminals of auditory nerve fibers, whereas VGLUT2 is mainly associated with glutamatergic terminals deriving from other sources that project to the cochlear nucleus (CN), including somatosensory and vestibular terminals. Previous studies in guinea pig have shown that cochlear damage results in a decrease of VGLUT1-labeled puncta and an increase in VGLUT2-labeled puncta. This indicates cross-modal compensation that is of potential importance in somatic tinnitus. To examine whether this effect is consistent across species and to provide a background for future studies, using transgenesis, the current study examines VGLUT expression profiles upon cochlear insult by intracochlear kanamycin injections in the mouse. Intracochlear kanamycin injections abolished ipsilateral ABR responses in all animals and reduced ipsilateral spiral ganglion neuron densities in animals that were sacrificed after four weeks, but not in animals that were sacrificed after three weeks. In all unilaterally deafened animals, VGLUT1 density was decreased in CN regions that receive auditory nerve fiber terminals, i.e. in the deep layer of the dorsal cochlear nucleus (DCN), in the interstitial region where the auditory nerve enters the CN, and in the magnocellular region of the antero- and posteroventral CN. In contrast, density of VGLUT2 expression was upregulated in the fusiform cell layer of the DCN and in the granule cell lamina, which are known to receive somatosensory and vestibular terminals. These results show that a cochlear insult induces cross-modal compensation in the cochlear nucleus of the mouse, confirming previous findings in guinea pig, and that these changes are not dependent on the occurrence of spiral ganglion neuron degeneration. PMID:26705736
Heeringa, A N; Stefanescu, R A; Raphael, Y; Shore, S E
2016-02-19
Vesicular glutamate transporters 1 and 2 (VGLUT1 and VGLUT2) have distinct distributions in the cochlear nucleus that correspond to sources of the labeled terminals. VGLUT1 is mainly associated with terminals of auditory nerve fibers, whereas VGLUT2 is mainly associated with glutamatergic terminals deriving from other sources that project to the cochlear nucleus (CN), including somatosensory and vestibular terminals. Previous studies in guinea pig have shown that cochlear damage results in a decrease of VGLUT1-labeled puncta and an increase in VGLUT2-labeled puncta. This indicates cross-modal compensation that is of potential importance in somatic tinnitus. To examine whether this effect is consistent across species and to provide a background for future studies, using transgenesis, the current study examines VGLUT expression profiles upon cochlear insult by intracochlear kanamycin injections in the mouse. Intracochlear kanamycin injections abolished ipsilateral ABR responses in all animals and reduced ipsilateral spiral ganglion neuron densities in animals that were sacrificed after four weeks, but not in animals that were sacrificed after three weeks. In all unilaterally deafened animals, VGLUT1 density was decreased in CN regions that receive auditory nerve fiber terminals, i.e., in the deep layer of the dorsal cochlear nucleus (DCN), in the interstitial region where the auditory nerve enters the CN, and in the magnocellular region of the antero- and posteroventral CN. In contrast, density of VGLUT2 expression was upregulated in the fusiform cell layer of the DCN and in the granule cell lamina, which are known to receive somatosensory and vestibular terminals. These results show that a cochlear insult induces cross-modal compensation in the cochlear nucleus of the mouse, confirming previous findings in guinea pig, and that these changes are not dependent on the occurrence of spiral ganglion neuron degeneration. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.
Bringing Hearing to the Deaf--Cochlear Implants: a Technical and Personal Account
NASA Astrophysics Data System (ADS)
Shipsey, Ian
2006-04-01
Cochlear implants are the first device to successfully restore neural function. They have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. In this talk the physiology of natural hearing will be reviewed from the perspective of a physicist, and the function of cochlear implants will be described in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. The social implications of cochlear implantation and the future outlook for auditory prostheses will also be discussed.
Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.
Chung, King; McKibben, Nicholas
2011-10-01
Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before and after the pre-emphasis filter, were analyzed. Correlation coefficients between speech recognition scores and crest factors of wind noise before and after pre-emphasis filtering were also calculated. Listeners obtained higher scores using the omnidirectional than the directional microphone mode at 13.5 m/sec, but they obtained similar speech recognition scores for the two microphone modes at 4.5 m/sec. Higher correlation coefficients were obtained between speech recognition scores and crest factors of wind noise after pre-emphasis filtering rather than before filtering. Cochlear implant users would benefit from both directional and omnidirectional microphones to reduce far-field background noise and near-field wind noise. Automatic microphone switching algorithms can be more effective if the incoming signal were analyzed after pre-emphasis filters for microphone switching decisions. American Academy of Audiology.
Exploring the Language and Literacy Outcomes of Pediatric Cochlear Implant Users
Spencer, Linda J.; Barker, Brittan A.; Tomblin, J. Bruce
2011-01-01
Objective The principal goal of this study was to investigate the relationship between language and literacy (i.e., reading and writing) skills in pediatric cochlear implant users. A peripheral objective was to identify the children's skills that were in need of remediation and subsequently to provide suggestions for remedial programming. It was predicted that the robust language skills often associated with children who have cochlear implant experience would facilitate the development of literacy skills. It was further proposed that the language and literacy skills of pediatric cochlear implant users would approximate the language and literacy skills of children with normal hearing. Design Sixteen pediatric cochlear implant users' language and literacy skills were evaluated and then compared with a reference group of 16 age-matched, normal-hearing children. All 32 participants were educated in mainstream classes within the public school system in the Midwest. The “Sentence Formulation” and “Concepts and Directions” subtests of the Clinical Evaluation of Language Fundamentals-3 test were used to evaluate receptive and expressive language skills. Reading comprehension was evaluated with the “Paragraph Comprehension” subtest of the Woodcock Reading Mastery Test. Performance measures for the writing analyses included productivity, complexity and grammaticality measures. Results Children with cochlear implants performed within 1 SD of the normal-hearing, age-matched children on measures of language comprehension, reading comprehension and writing accuracy. However, the children with cochlear implants performed significantly poorer than the children with normal hearing on the expressive “Sentence Formulation” subtest. The cochlear implant users also produced fewer words on the written narrative task than did the normal-hearing children, although there was not a significant difference between groups with respect to total words per clause. Furthermore there was a strong correlation between language performance and reading performance, as well as language performance and total words produced on the written performance measure for the children using cochlear implants. Conclusions The results of this study suggest that the language skills of pediatric cochlear implant users are related to and correlated with the development of literacy skills within these children. Consequently, the performance of the cochlear implant users, on various language and literacy measures, compared favorably to an age-matched group of children with normal hearing. There were significant differences in the ability of the cochlear implant users to correctly utilize grammatical structures such as conjunctions and correct verb forms when they were required to formulate written and oral sentences. Given this information, it would be appropriate for their educational or remedial language programs to emphasize the use and development of these structures. PMID:12799546
Cochlear implants and ex vivo BDNF gene therapy protect spiral ganglion neurons.
Rejali, Darius; Lee, Valerie A; Abrashkin, Karen A; Humayun, Nousheen; Swiderski, Donald L; Raphael, Yehoash
2007-06-01
Spiral ganglion neurons often degenerate in the deaf ear, compromising the function of cochlear implants. Cochlear implant function can be improved by good preservation of the spiral ganglion neurons, which are the target of electrical stimulation by the implant. Brain derived neurotrophic factor (BDNF) has previously been shown to enhance spiral ganglion survival in experimentally deafened ears. Providing enhanced levels of BDNF in human ears may be accomplished by one of several different methods. The goal of these experiments was to test a modified design of the cochlear implant electrode that includes a coating of fibroblast cells transduced by a viral vector with a BDNF gene insert. To accomplish this type of ex vivo gene transfer, we transduced guinea pig fibroblasts with an adenovirus with a BDNF gene cassette insert, and determined that these cells secreted BDNF. We then attached BDNF-secreting cells to the cochlear implant electrode via an agarose gel, and implanted the electrode in the scala tympani. We determined that the BDNF expressing electrodes were able to preserve significantly more spiral ganglion neurons in the basal turns of the cochlea after 48 days of implantation when compared to control electrodes. This protective effect decreased in the higher cochlear turns. The data demonstrate the feasibility of combining cochlear implant therapy with ex vivo gene transfer for enhancing spiral ganglion neuron survival.
Is there a best side for cochlear implants in post-lingual patients?
Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo
2017-07-29
Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Cochlear implants and medical tourism.
McKinnon, Brian J; Bhatt, Nishant
2010-09-01
To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.
Eckhard, A; Löwenheim, H
2014-06-01
Sound transduction in the cochlea critically depends on the circulation of potassium ions (K(+)) along so-called "K(+) recycling routes" between the endolymph and perilymph. These K(+) currents generate high ionic and osmotic gradients, which potentially impair the excitability of sensory hair cells and threaten cell survival in the entire cochlear duct. Molecular water channels-aquaporins (AQP)-are expressed in all cochlear supporting cells along the K(+) recycling routes; however, their significance for osmotic equilibration in cochlear duct cells is unknown. The diffusive and osmotic water permeabilies of Reissner's membrane, the organ of Corti and the entire cochlear duct epithelium were determined. Expression of the potassium channel Kir4.1 and the water channel AQP4 in the cochlear duct was investigated by immunohistochemistry. The calculated water permeability values indicate the extent of AQP-facilitated water flux across the cochlear duct epithelium. Immunohistochemically, Kir4.1 and AQP4 were found to colocalize in distinct membrane domains of supporting cells along the K(+)-recycling routes. These observations suggest the presence of a rapid AQP-mediated water exchange between the endolymph, the cells of the cochlear duct and the perilymph. The subcellular colocalization of Kir4.1 and AQP4 in epithelial supporting cells indicates functional coupling of potassium and water flow in the cochlea. Finally, this offers an explanation for the hearing impairment observed in individuals with mutations in the AQP4 gene.
Bilateral cochlear implantation in the ferret: A novel animal model for behavioral studies
Hartley, Douglas E.H.; Vongpaisal, Tara; Xu, Jin; Shepherd, Robert K.; King, Andrew J.; Isaiah, Amal
2010-01-01
Bilateral cochlear implantation has recently been introduced with the aim of improving both speech perception in background noise and sound localization. Although evidence suggests that binaural perception is possible with two cochlear implants, results in humans are variable. To explore potential contributing factors to these variable outcomes, we have developed a behavioral animal model of bilateral cochlear implantation in a novel species, the ferret. Although ferrets are ideally suited to psychophysical and physiological assessments of binaural hearing, cochlear implantation has not been previously described in this species. This paper describes the techniques of deafening with aminoglycoside administration, surgical implantation of an intracochlear array and chronic intracochlear electrical stimulation with monitoring for electrode integrity and efficacy of stimulation. Experiments have been presented elsewhere to show that the model can be used to study behavioral and electrophysiological measures of binaural hearing in chronically implanted animals. This paper demonstrates that cochlear implantation and chronic intracochlear electrical stimulation are both safe and effective in ferrets, opening up the possibility of using this model to study potential protective effects of bilateral cochlear implantation on the developing central auditory pathway. Since ferrets can be used to assess psychophysical and physiological aspects of hearing along with the structure of the auditory pathway in the same animals, we anticipate that this model will help develop novel neuroprosthetic therapies for use in humans. PMID:20576507
Powell, Harry R F; Birman, Catherine S
2015-01-01
The aim of this study was to assess if large vestibular aqueduct syndrome (LVAS), with the increase in perilymphatic pressure, affects impedance changes over time with different types of Cochlear(®) implant electrode arrays Contour, Straight, and CI 422. To report speech perception outcomes for these cochlear implant recipients. Retrospective case review of impedance levels and categories of auditory performance. Impedance data were collected at switch on, 1 month, 3, 6, 12, and 24 months after cochlear implantation and compared with control (non-LVAS cochlear implant recipient) data for each array type. Forty-seven patients with exclusive LVAS and no other vestibulocochlear abnormalities or other identifiable cause of deafness were eligible for inclusion in the study. In LVAS patients, there was a significant difference in impedance between the three types of device (P < 0.0001). Time since switch on was associated with a decrease in impedance for all three devices (P < 0.0001). The mean impedance reduced between switch on and 1 month and remained relatively constant thereafter. Sound variation with softening of sounds was seen in four CI 422 (Straight Research Array) recipients due to ongoing fluctuations in electrode compliance. For all three array types, there was no significant difference in the mean impedance between the LVAS patients and controls over the first 12 months. In keeping with previous studies cochlear implant recipients with LVAS hear very well through the cochlear implant.
Johannesen, Peter T.; Pérez-González, Patricia; Kalluri, Sridhar; Blanco, José L.
2016-01-01
The aim of this study was to assess the relative importance of cochlear mechanical dysfunction, temporal processing deficits, and age on the ability of hearing-impaired listeners to understand speech in noisy backgrounds. Sixty-eight listeners took part in the study. They were provided with linear, frequency-specific amplification to compensate for their audiometric losses, and intelligibility was assessed for speech-shaped noise (SSN) and a time-reversed two-talker masker (R2TM). Behavioral estimates of cochlear gain loss and residual compression were available from a previous study and were used as indicators of cochlear mechanical dysfunction. Temporal processing abilities were assessed using frequency modulation detection thresholds. Age, audiometric thresholds, and the difference between audiometric threshold and cochlear gain loss were also included in the analyses. Stepwise multiple linear regression models were used to assess the relative importance of the various factors for intelligibility. Results showed that (a) cochlear gain loss was unrelated to intelligibility, (b) residual cochlear compression was related to intelligibility in SSN but not in a R2TM, (c) temporal processing was strongly related to intelligibility in a R2TM and much less so in SSN, and (d) age per se impaired intelligibility. In summary, all factors affected intelligibility, but their relative importance varied across maskers. PMID:27604779
Parents' Views on Changing Communication after Cochlear Implantation
ERIC Educational Resources Information Center
Watson, Linda M.; Hardie, Tim; Archbold, Sue M.; Wheeler, Alexandra
2008-01-01
We sent questionnaires to families of all 288 children who had received cochlear implants at one center in the United Kingdom at least 5 years previously. Thus, it was a large, unselected group. We received 142 replies and 119 indicated that the child and family had changed their communication approach following cochlear implantation. In 113 cases…
Changes in Speech Production in an Early Deafened Adult with a Cochlear Implant
ERIC Educational Resources Information Center
Wong, Patrick C. M.
2007-01-01
Background and Aims: The current study is a first investigation reporting the speech production characteristics of an early deafened adult cochlear implant user after a course of speech-language treatment. Methods and Procedures: The participant is culturally deaf and received the cochlear implant when she was 43 years old. A 24-week ABCABC…
The Self-Regulation of a Child with Cochlear Implants within a School Environment
ERIC Educational Resources Information Center
Patton, Kristin L.
2013-01-01
The purpose of this qualitative research, which utilized a narrative design strategy, was to describe the process of self-regulation of a child who has bilateral cochlear implants within the social environment of school. The study investigated the use of self-regulatory strategies by the cochlear implant recipient. It also examined how the child…
ERIC Educational Resources Information Center
Bertram, Bodo
2004-01-01
In recent years, parents of children with hearing loss and various additional disabilities have shown increasing interest in cochlear implants. This article describes how the program in Hanover, Germany is attempting to respond to this interest. It discusses the selection process for children who receive cochlear implants who have multiple…
Spelling in Written Stories by School-Age Children with Cochlear Implants
ERIC Educational Resources Information Center
Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel
2016-01-01
This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…
de Kleijn, Jasper L; van Kalmthout, Ludwike W M; van der Vossen, Martijn J B; Vonck, Bernard M D; Topsakal, Vedat; Bruijnzeel, Hanneke
2018-05-24
Although current guidelines recommend cochlear implantation only for children with profound hearing impairment (HI) (>90 decibel [dB] hearing level [HL]), studies show that children with severe hearing impairment (>70-90 dB HL) could also benefit from cochlear implantation. To perform a systematic review to identify audiologic thresholds (in dB HL) that could serve as an audiologic candidacy criterion for pediatric cochlear implantation using 4 domains of speech and language development as independent outcome measures (speech production, speech perception, receptive language, and auditory performance). PubMed and Embase databases were searched up to June 28, 2017, to identify studies comparing speech and language development between children who were profoundly deaf using cochlear implants and children with severe hearing loss using hearing aids, because no studies are available directly comparing children with severe HI in both groups. If cochlear implant users with profound HI score better on speech and language tests than those with severe HI who use hearing aids, this outcome could support adjusting cochlear implantation candidacy criteria to lower audiologic thresholds. Literature search, screening, and article selection were performed using a predefined strategy. Article screening was executed independently by 4 authors in 2 pairs; consensus on article inclusion was reached by discussion between these 4 authors. This study is reported according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Title and abstract screening of 2822 articles resulted in selection of 130 articles for full-text review. Twenty-one studies were selected for critical appraisal, resulting in selection of 10 articles for data extraction. Two studies formulated audiologic thresholds (in dB HLs) at which children could qualify for cochlear implantation: (1) at 4-frequency pure-tone average (PTA) thresholds of 80 dB HL or greater based on speech perception and auditory performance subtests and (2) at PTA thresholds of 88 and 96 dB HL based on a speech perception subtest. In 8 of the 18 outcome measures, children with profound HI using cochlear implants performed similarly to children with severe HI using hearing aids. Better performance of cochlear implant users was shown with a picture-naming test and a speech perception in noise test. Owing to large heterogeneity in study population and selected tests, it was not possible to conduct a meta-analysis. Studies indicate that lower audiologic thresholds (≥80 dB HL) than are advised in current national and manufacturer guidelines would be appropriate as audiologic candidacy criteria for pediatric cochlear implantation.
Meyer, Ted A.; Frisch, Stefan A.; Pisoni, David B.; Miyamoto, Richard T.; Svirsky, Mario A.
2012-01-01
Hypotheses Do cochlear implants provide enough information to allow adult cochlear implant users to understand words in ways that are similar to listeners with acoustic hearing? Can we use a computational model to gain insight into the underlying mechanisms used by cochlear implant users to recognize spoken words? Background The Neighborhood Activation Model has been shown to be a reasonable model of word recognition for listeners with normal hearing. The Neighborhood Activation Model assumes that words are recognized in relation to other similar-sounding words in a listener’s lexicon. The probability of correctly identifying a word is based on the phoneme perception probabilities from a listener’s closed-set consonant and vowel confusion matrices modified by the relative frequency of occurrence of the target word compared with similar-sounding words (neighbors). Common words with few similar-sounding neighbors are more likely to be selected as responses than less common words with many similar-sounding neighbors. Recent studies have shown that several of the assumptions of the Neighborhood Activation Model also hold true for cochlear implant users. Methods Closed-set consonant and vowel confusion matrices were obtained from 26 postlingually deafened adults who use cochlear implants. Confusion matrices were used to represent input errors to the Neighborhood Activation Model. Responses to the different stimuli were then generated by the Neighborhood Activation Model after incorporating the frequency of occurrence counts of the stimuli and their neighbors. Model outputs were compared with obtained performance measures on the Consonant-Vowel Nucleus-Consonant word test. Information transmission analysis was used to assess whether the Neighborhood Activation Model was able to successfully generate and predict word and individual phoneme recognition by cochlear implant users. Results The Neighborhood Activation Model predicted Consonant-Vowel Nucleus-Consonant test words at levels similar to those correctly identified by the cochlear implant users. The Neighborhood Activation Model also predicted phoneme feature information well. Conclusion The results obtained suggest that the Neighborhood Activation Model provides a reasonable explanation of word recognition by postlingually deafened adults after cochlear implantation. It appears that multichannel cochlear implants give cochlear implant users access to their mental lexicons in a manner that is similar to listeners with acoustic hearing. The lexical properties of the test stimuli used to assess performance are important to spoken-word recognition and should be included in further models of the word recognition process. PMID:12851554
Evaluation on health-related quality of life in deaf children with cochlear implant in China.
Liu, Hong; Liu, Hong-Xiang; Kang, Hou-Yong; Gu, Zheng; Hong, Su-Ling
2016-09-01
Previous studies have shown that deaf children benefit considerably from cochlear implants. These improvements are found in areas such as speech perception, speech production, and audiology-verbal performance. Despite the increasing prevalence of cochlear implants in China, few studies have reported on health-related quality of life in children with cochlear implants. The main objective of this study was to explore health-related quality of life on children with cochlear implants in South-west China. A retrospective observational study of 213 CI users in Southwest China between 2010 and 2013. Participants were 213 individuals with bilateral severe-to-profound hearing loss who wore unilateral cochlear implants. The Nijmegen Cochlear Implant Questionnaire and Health Utility Index Mark III were used pre-implantation and 1 year post-implantation. Additionally, 1-year postoperative scores for Mandarin speech perception were compared with preoperative scores. Health-related quality of life improved post-operation with scores on the Nijmegen Cochlear Implant Questionnaire improving significantly in all subdomains, and the Health Utility Index 3 showing a significant improvement in the utility score and the subdomains of ''hearing," ''speech," and "emotion". Additionally, a significant improvement in speech recognition scores was found. No significant correlation was found between increased in quality of life and speech perception scores. Health-related quality of life and speech recognition in prelingual deaf children significantly improved post-operation. The lack of correlation between quality of life and speech perception suggests that when evaluating performance post-implantation in prelingual deaf children and adolescents, measures of both speech perception and quality of life should be used. Copyright © 2016. Published by Elsevier Ireland Ltd.
Hey, Constanze; Shaaban, Mohamed S; Elabd, Amr M; Hassan, Hebatallah H M; Gruber-Rouh, Tatjana; Kaltenbach, Benjamin; Harth, Marc; Ackermann, Hanns; Stöver, Timo; Vogl, Thomas J; Nour-Eldin, Nour-Eldin A
2017-01-01
Objective: To test using the facial nerve as a reference for assessment of the cochlear nerve size in patients with acquired long-standing sensorineural hearing loss (SNHL) using MRI multiplanar reconstruction. Methods: The study was retrospectively performed on 86 patients. Group 1 (study group, n = 53) with bilateral long-standing SNHL. Group 2 (control group, n = 33) without hearing loss. The nerve size was measured by drawing a region of interest around the cross-sectional circumference of the nerve in multiplanar reconstruction images. Results: No significant correlation was noted between the cochlear nerve and facial nerve size, and the patient's age, gender and weight (p > 0.05). In Group 1, the mean ratio of the cochlear to facial nerve size was 0.99 ± 0.30 (range: 0.52–1.86) and 1.12 ± 0.35 (range: 0.34–2.3) for the right and left sides, respectively. In Group 2, it was 1.18 ± 0.23 (range: 0.78–1.71) and 1.25 ± 0.25 (range: 0.85–1.94) for the right and left sides, respectively. The cochlear nerve size was statistically (p = 0.0004) smaller in Group 1 than in Group 2. Conclusion: The cochlear nerve size and the cochlear to facial nerve size ratio are significantly smaller in patients with acquired long-standing SNHL. Advances in knowledge: The facial nerve can be used as a reference for assessment of the cochlear nerve in patients with acquired long-standing SNHL. PMID:28368665
Cochlear microphonic broad tuning curves
NASA Astrophysics Data System (ADS)
Ayat, Mohammad; Teal, Paul D.; Searchfield, Grant D.; Razali, Najwani
2015-12-01
It is known that the cochlear microphonic voltage exhibits much broader tuning than does the basilar membrane motion. The most commonly used explanation for this is that when an electrode is inserted at a particular point inside the scala media, the microphonic potentials of neighbouring hair cells have different phases, leading to cancelation at the electrodes location. In situ recording of functioning outer hair cells (OHCs) for investigating this hypothesis is exceptionally difficult. Therefore, to investigate the discrepancy between the tuning curves of the basilar membrane and those of the cochlear microphonic, and the effect of phase cancellation of adjacent hair cells on the broadness of the cochlear microphonic tuning curves, we use an electromechanical model of the cochlea to devise an experiment. We explore the effect of adjacent hair cells (i.e., longitudinal phase cancellation) on the broadness of the cochlear microphonic tuning curves in different locations. The results of the experiment indicate that active longitudinal coupling (i.e., coupling with active adjacent outer hair cells) only slightly changes the broadness of the CM tuning curves. The results also demonstrate that there is a π phase difference between the potentials produced by the hair bundle and the soma near the place associated with the characteristic frequency based on place-frequency maps (i.e., the best place). We suggest that the transversal phase cancellation (caused by the phase difference between the hair bundle and the soma) plays a far more important role than longitudinal phase cancellation in the broadness of the cochlear microphonic tuning curves. Moreover, by increasing the modelled longitudinal resistance resulting the cochlear microphonic curves exhibiting sharper tuning. The results of the simulations suggest that the passive network of the organ of Corti determines the phase difference between the hair bundle and soma, and hence determines the sharpness of the cochlear microphonic tuning curves.
The auditory nerve overlapped waveform (ANOW): A new objective measure of low-frequency hearing
NASA Astrophysics Data System (ADS)
Lichtenhan, Jeffery T.; Salt, Alec N.; Guinan, John J.
2015-12-01
One of the most pressing problems today in the mechanics of hearing is to understand the mechanical motions in the apical half of the cochlea. Almost all available measurements from the cochlear apex of basilar membrane or other organ-of-Corti transverse motion have been made from ears where the health, or sensitivity, in the apical half of the cochlea was not known. A key step in understanding the mechanics of the cochlear base was to trust mechanical measurements only when objective measures from auditory-nerve compound action potentials (CAPs) showed good preparation sensitivity. However, such traditional objective measures are not adequate monitors of cochlear health in the very low-frequency regions of the apex that are accessible for mechanical measurements. To address this problem, we developed the Auditory Nerve Overlapped Waveform (ANOW) that originates from auditory nerve output in the apex. When responses from the round window to alternating low-frequency tones are averaged, the cochlear microphonic is canceled and phase-locked neural firing interleaves in time (i.e., overlaps). The result is a waveform that oscillates at twice the probe frequency. We have demonstrated that this Auditory Nerve Overlapped Waveform - called ANOW - originates from auditory nerve fibers in the cochlear apex [8], relates well to single-auditory-nerve-fiber thresholds, and can provide an objective estimate of low-frequency sensitivity [7]. Our new experiments demonstrate that ANOW is a highly sensitive indicator of apical cochlear function. During four different manipulations to the scala media along the cochlear spiral, ANOW amplitude changed when either no, or only small, changes occurred in CAP thresholds. Overall, our results demonstrate that ANOW can be used to monitor cochlear sensitivity of low-frequency regions during experiments that make apical basilar membrane motion measurements.
Cochlear implantation in autistic children with profound sensorineural hearing loss.
Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz
2016-11-19
Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Music training improves pitch perception in prelingually deafened children with cochlear implants.
Chen, Joshua Kuang-Chao; Chuang, Ann Yi Chiun; McMahon, Catherine; Hsieh, Jen-Chuen; Tung, Tao-Hsin; Li, Lieber Po-Hung
2010-04-01
The comparatively poor music appreciation in patients with cochlear implants might be ascribed to an inadequate exposure to music; however, the effect of training on music perception in prelingually deafened children with cochlear implants remains unknown. This study aimed to investigate whether previous musical education improves pitch perception ability in these children. Twenty-seven children with congenital/prelingual deafness of profound degree were studied. Test stimuli consisted of 2 sequential piano tones, ranging from C (256 Hz) to B (495 Hz). Children were asked to identify the pitch relationship between the 2 tones (same, higher, or lower). Effects of musical training duration, pitch-interval size, current age, age of implantation, gender, and type of cochlear implant on accuracy of pitch perception were evaluated. The duration of musical training positively correlated with the correct rate of pitch perception. Pitch perception performance was better in children who had a cochlear implant and were older than 6 years than in those who were aged < or =6 years (ie, preschool). Effect of pitch-interval size was insignificant on pitch perception, and there was no correlation between pitch perception and the age of implantation, gender, or type of cochlear implant. Musical training seems to improve pitch perception ability in prelingually deafened children with a cochlear implant. Auditory plasticity might play an important role in such enhancement. This suggests that incorporation of a structured training program on music perception early in life and as part of the postoperative rehabilitation program for prelingually deafened children with cochlear implants would be beneficial. A longitudinal study is needed to show whether improvement of music performance in these children is measurable by use of auditory evoked potentials.
Auditory Speech Perception Development in Relation to Patient's Age with Cochlear Implant
Ciscare, Grace Kelly Seixas; Mantello, Erika Barioni; Fortunato-Queiroz, Carla Aparecida Urzedo; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa dos
2017-01-01
Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1. PMID:28680487
Auditory Mechanics of the Tectorial Membrane and the Cochlear Spiral
Gavara, Núria; Manoussaki, Daphne; Chadwick, Richard S.
2012-01-01
Purpose of review This review is timely and relevant since new experimental and theoretical findings suggest that cochlear mechanics from the nanoscale to the macroscale are affected by mechanical properties of the tectorial membrane and the spiral shape. Recent findings Main tectorial membrane themes covered are i) composition and morphology, ii) nanoscale mechanical interactions with the outer hair cell bundle, iii) macroscale longitudinal coupling, iv) fluid interaction with inner hair cell bundles, v) macroscale dynamics and waves. Main cochlear spiral themes are macroscale low-frequency energy focusing and microscale organ of Corti shear gain. Implications Findings from new experimental and theoretical models reveal exquisite sensitivity of cochlear mechanical performance to tectorial membrane structural organization, mechanics, and its positioning with respect to hair bundles. The cochlear spiral geometry is a major determinant of low frequency hearing. Suggestions are made for future research directions. PMID:21785353
[Pre-operation evaluation and intra-operation management of cochlear implantation].
Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning
2004-10-01
To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.
Yanov, Yu K; Kuzovkov, V E; Lilenko, A S; Kostevich, I V; Sugarova, S B; Amonov, A Sh
The mode of the introduction of the active electrode of a cochlear implant into the cochlea remains a key issue as far as cochlear implantation is concerned. Especially much attention has recently been given to the relationship between the anatomical features of the basal region of the cochlea (the so-called 'fish hook') and the possibility to approach it. We have undertaken the attempt to optimize the approach to the tympanic canal (scala tympanica) of the cochlea with a view to reducing to a minimum the risk of an injury to the cochlear structures in the course of cochlear implantation. A total of 35 cadaveric temporal bones were examined to measure the fine structures of the hook region and evaluate the risk of their damages associated with various approaches to the tympanic canal.
Congenitally deafblind children and cochlear implants: effects on communication.
Dammeyer, Jesper
2009-01-01
There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2 years of age. Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about CI in their deafblind children. Benefits of CI in this cohort of children included improved attention and emotional response as well as greater use of objects in interaction with adults. The best overall outcome of CI is not spoken language but better communication.
Disorders of cochlear blood flow.
Nakashima, Tsutomu; Naganawa, Shinji; Sone, Michihiko; Tominaga, Mitsuo; Hayashi, Hideo; Yamamoto, Hiroshi; Liu, Xiuli; Nuttall, Alfred L
2003-09-01
The cochlea is principally supplied from the inner ear artery (labyrinthine artery), which is usually a branch of the anterior inferior cerebellar artery. Cochlear blood flow is a function of cochlear perfusion pressure, which is calculated as the difference between mean arterial blood pressure and inner ear fluid pressure. Many otologic disorders such as noise-induced hearing loss, endolymphatic hydrops and presbycusis are suspected of being related to alterations in cochlear blood flow. However, the human cochlea is not easily accessible for investigation because this delicate sensory organ is hidden deep in the temporal bone. In patients with sensorineural hearing loss, magnetic resonance imaging, laser-Doppler flowmetry and ultrasonography have been used to investigate the status of cochlear blood flow. There have been many reports of hearing loss that were considered to be caused by blood flow disturbance in the cochlea. However, direct evidence of blood flow disturbance in the cochlea is still lacking in most of the cases.
Language, Mental State Vocabulary, and False Belief Understanding in Children with Cochlear Implants
ERIC Educational Resources Information Center
Peters, Kimberly; Remmel, Ethan; Richards, Debra
2009-01-01
Purpose: This study examined false belief understanding and its predictors in school-age children who are deaf with cochlear implants and who use spoken language. Method: False belief understanding was measured through an explanation-of-action task in 30 children between the ages of 3 and 12 years who used cochlear implants. Children told a…
Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era
ERIC Educational Resources Information Center
Valente, Joseph Michael
2011-01-01
The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…
ERIC Educational Resources Information Center
National Institutes of Health (DHHS), Bethesda, MD.
This paper reports the results of a Consensus Development Conference on Cochlear Implants sponsored by the National Institutes of Health to improve the hearing of children and adults with hearing impairments. The following questions are addressed: (1) Who is a suitable candidate for a cochlear implant? (2) What are the advantages and disadvantages…
Auditory Environment across the Life Span of Cochlear Implant Users: Insights from Data Logging
ERIC Educational Resources Information Center
Busch, Tobias; Vanpoucke, Filiep; van Wieringen, Astrid
2017-01-01
Purpose: We describe the natural auditory environment of people with cochlear implants (CIs), how it changes across the life span, and how it varies between individuals. Method: We performed a retrospective cross-sectional analysis of Cochlear Nucleus 6 CI sound-processor data logs. The logs were obtained from 1,501 people with CIs (ages 0-96…
Congenitally Deafblind Children and Cochlear Implants: Effects on Communication
ERIC Educational Resources Information Center
Dammeyer, Jesper
2009-01-01
There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…
ERIC Educational Resources Information Center
Zaidman-Zait, Anat; Jamieson, Janet R.
2004-01-01
The present study has three purposes: (a) to determine who disseminates information on cochlear implants on the Web; (b) to describe a representative sample of Web sites that disseminate information on cochlear implants, with a focus on the content topics and their relevance to parents of deaf children; and (c) to discuss the practical issues of…
Benefit of Wearing a Hearing Aid on the Unimplanted Ear in Adult Users of a Cochlear Implant
ERIC Educational Resources Information Center
Dunn, Camille C.; Tyler, Richard S.; Witt, Shelley A.
2005-01-01
The purpose of this investigation was to document performance of participants wearing a cochlear implant and hearing aid in opposite ears on speech-perception and localization tests. Twelve individuals who wore a cochlear implant and a hearing aid on contralateral ears were tested on their abilities to understand words in quiet and sentences in…
ERIC Educational Resources Information Center
Reeder, Ruth M.; Firszt, Jill B.; Cadieux, Jamie H.; Strube, Michael J.
2017-01-01
Purpose: Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization…
Educational Interpreters: Meeting the Communication Needs of Children with Cochlear Implants
ERIC Educational Resources Information Center
Melton, Julie; Higbee, Renee
2013-01-01
Since the early 1990s, when the U.S. Food and Drug Administration approved cochlear implants for deaf and hard of hearing children, the number of children who have cochlear implants has increased in mainstream settings. Recent research suggests that these students, like their deaf and hard of hearing peers without implants who use sign language,…
Prevention and management of cochlear implant infections.
Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D
2011-11-01
Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramamoorthy, Sripriya; Zhang, Yuan; Jacques, Steven
In this study, we have developed a phase-sensitive Fourier-domain optical coherence tomography system to simultaneously measure the in vivo inner ear vibrations in the hook area and second turn of the mouse cochlea. This technical development will enable measurement of intra-cochlear distortion products at ideal locations such as the distortion product generation site and reflection site. This information is necessary to un-mix the complex mixture of intra-cochlear waves comprising the DPOAE and thus leads to the non-invasive identification of the local region of cochlear damage.
Use of Neural Response Telemetry for Pediatric Cochlear Implants: Current Practice.
Almosnino, Galit; Anne, Samantha; Schwartz, Seth R
2018-06-01
Evaluate usage trends of neural response telemetry (NRT) in cochlear implant centers across the nation and assess reported benefits of intraoperative NRT for pediatric cochlear implant recipients. Survey. All US cochlear implant centers (n = 110). A 15-question multiple-choice survey was distributed electronically to all centers. The survey captured demographic information of all centers, practice patterns surrounding the use of NRT, and the extent to which intraoperative NRT is of benefit. Thirty-two invited participants (29%) completed the survey. A majority of participants reported practicing in an academic center (66%), followed by a hospital setting (19%) and private practice (16%). Seventy-two percent of survey participants reported using NRT for pediatric cochlear implant recipients. Sixty-three percent felt it improved the ability to program at initial activation, and 50% of participants felt that NRT improves satisfaction at initial activation. This study suggests that a majority of surgeons use intraoperative NRT for pediatric cochlear implantation as an additional measure to ensure appropriate electrode placement and improve device activation. Larger studies are needed to better establish the relationship between intraoperative NRT and postoperative outcomes and justify the additional costs associated with intraoperative NRT.
Topics in Modeling of Cochlear Dynamics: Computation, Response and Stability Analysis
NASA Astrophysics Data System (ADS)
Filo, Maurice G.
This thesis touches upon several topics in cochlear modeling. Throughout the literature, mathematical models of the cochlea vary according to the degree of biological realism to be incorporated. This thesis casts the cochlear model as a continuous space-time dynamical system using operator language. This framework encompasses a wider class of cochlear models and makes the dynamics more transparent and easier to analyze before applying any numerical method to discretize space. In fact, several numerical methods are investigated to study the computational efficiency of the finite dimensional realizations in space. Furthermore, we study the effects of the active gain perturbations on the stability of the linearized dynamics. The stability analysis is used to explain possible mechanisms underlying spontaneous otoacoustic emissions and tinnitus. Dynamic Mode Decomposition (DMD) is introduced as a useful tool to analyze the response of nonlinear cochlear models. Cochlear response features are illustrated using DMD which has the advantage of explicitly revealing the spatial modes of vibrations occurring in the Basilar Membrane (BM). Finally, we address the dynamic estimation problem of BM vibrations using Extended Kalman Filters (EKF). Due to the limitations of noninvasive sensing schemes, such algorithms are inevitable to estimate the dynamic behavior of a living cochlea.
Voice gender identification by cochlear implant users: The role of spectral and temporal resolution
NASA Astrophysics Data System (ADS)
Fu, Qian-Jie; Chinchilla, Sherol; Nogaki, Geraldine; Galvin, John J.
2005-09-01
The present study explored the relative contributions of spectral and temporal information to voice gender identification by cochlear implant users and normal-hearing subjects. Cochlear implant listeners were tested using their everyday speech processors, while normal-hearing subjects were tested under speech processing conditions that simulated various degrees of spectral resolution, temporal resolution, and spectral mismatch. Voice gender identification was tested for two talker sets. In Talker Set 1, the mean fundamental frequency values of the male and female talkers differed by 100 Hz while in Talker Set 2, the mean values differed by 10 Hz. Cochlear implant listeners achieved higher levels of performance with Talker Set 1, while performance was significantly reduced for Talker Set 2. For normal-hearing listeners, performance was significantly affected by the spectral resolution, for both Talker Sets. With matched speech, temporal cues contributed to voice gender identification only for Talker Set 1 while spectral mismatch significantly reduced performance for both Talker Sets. The performance of cochlear implant listeners was similar to that of normal-hearing subjects listening to 4-8 spectral channels. The results suggest that, because of the reduced spectral resolution, cochlear implant patients may attend strongly to periodicity cues to distinguish voice gender.
Verbal Working Memory in Children With Cochlear Implants
Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.
2017-01-01
Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747
Punch, Renée; Hyde, Merv
2011-01-01
Psychosocial factors, including socioemotional well-being, peer relationships, and social inclusion with hearing and deaf peers, are increasingly becoming a focus of research investigating children with cochlear implants. The study reported here extends the largely quantitative findings of previous research through a qualitative analysis of interviews with parents, teachers, and pediatric cochlear implant users themselves in three eastern states of Australia. We interviewed 24 parents, 15 teachers, and 11 children and adolescents. The findings displayed commonalities across the three groups of participants, indicating positive experiences around the children's psychosocial development with their cochlear implants, but also ongoing difficulties communicating in groups of people and problems related to social skills. Some children had little contact with other deaf children (with or without cochlear implants) despite parents and teachers perceiving such contact beneficial. Children attending schools where there were other deaf children valued friendships with both deaf and hearing peers. Adolescence was a particularly difficult time for some as they struggled with feelings of self-consciousness about their deafness and external cochlear implant equipment and worries around friendships, dating, and their future place in the world. Recommendations for practice and further research are made.
Auditory Speech Perception Tests in Relation to the Coding Strategy in Cochlear Implant.
Bazon, Aline Cristine; Mantello, Erika Barioni; Gonçales, Alina Sanches; Isaac, Myriam de Lima; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa
2016-07-01
The objective of the evaluation of auditory perception of cochlear implant users is to determine how the acoustic signal is processed, leading to the recognition and understanding of sound. To investigate the differences in the process of auditory speech perception in individuals with postlingual hearing loss wearing a cochlear implant, using two different speech coding strategies, and to analyze speech perception and handicap perception in relation to the strategy used. This study is prospective cross-sectional cohort study of a descriptive character. We selected ten cochlear implant users that were characterized by hearing threshold by the application of speech perception tests and of the Hearing Handicap Inventory for Adults. There was no significant difference when comparing the variables subject age, age at acquisition of hearing loss, etiology, time of hearing deprivation, time of cochlear implant use and mean hearing threshold with the cochlear implant with the shift in speech coding strategy. There was no relationship between lack of handicap perception and improvement in speech perception in both speech coding strategies used. There was no significant difference between the strategies evaluated and no relation was observed between them and the variables studied.
Effects of a Word-Learning Training on Children With Cochlear Implants
Lund, Emily
2014-01-01
Preschool children with hearing loss who use cochlear implants demonstrate vocabulary delays when compared to their peers without hearing loss. These delays may be a result of deficient word-learning abilities; children with cochlear implants perform more poorly on rapid word-learning tasks than children with normal hearing. This study explored the malleability of rapid word learning of preschoolers with cochlear implants by evaluating the effects of a word-learning training on rapid word learning. A single-subject, multiple probe design across participants measured the impact of the training on children’s rapid word-learning performance. Participants included 5 preschool children with cochlear implants who had an expressive lexicon of less than 150 words. An investigator guided children to identify, repeat, and learn about unknown sets of words in 2-weekly sessions across 10 weeks. The probe measure, a rapid word-learning task with a different set of words than those taught during training, was collected in the baseline, training, and maintenance conditions. All participants improved their receptive rapid word-learning performance in the training condition. The functional relation indicates that the receptive rapid word-learning performance of children with cochlear implants is malleable. PMID:23981321
The cochlear implant as a tinnitus treatment.
Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio
2013-01-01
Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Cochlear implants and spoken language processing abilities: review and assessment of the literature.
Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T
2010-01-01
Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.
Lin, Yung-Song
2009-03-01
Cochlear implantation via the scala vestibuli is a viable approach in those with ossification in the scala tympani. With extended cochlear implant experience, there is no significant difference in the mapping parameters and auditory performance between those implanted via scala vestibuli and via scala tympani. To assess the clinical outcomes of cochlear implantation via scala vestibuli. In a cohort follow-up study, 11 prelingually deafened children who received cochlear implantation between age 3 and 10 years through the scala vestibuli served as participants. The mapping parameters (i.e. comfortable level (C), threshold level (T), dynamic range) and auditory performance of each participant were evaluated following initial cochlear implant stimulation, then at 3 month intervals for 2 years, then semi-annually. The follow-up period lasted for 9 years 9 months on average, with a minimum of 8 years 3 months. The clinical results of the mapping parameters and auditory performance of children implanted via the scala vestibuli were comparative to those who were implanted via the scala tympani. No balance problem was reported by any of these patients. One child exhibited residual low frequency hearing after implantation.
Current Research with Cochlear Implants at Arizona State University
Dorman, Michael F.; Spahr, Anthony; Gifford, Rene H.; Cook, Sarah; Zhang, Ting; Loiselle, Louise; Yost, William; Cardy, Lara; Whittingham, JoAnne; Schramm, David
2013-01-01
In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic listening environments, (3) accounting for the benefit provided to bimodal patients by low-frequency acoustic stimulation, (4) assessing localization by bilateral hearing aid patients and the implications of that work for hearing preservation patients, and (5) studying heart rate variability as a possible measure for quantifying the stress of listening via an implant. The long-term goals of the laboratory are to improve the performance of patients fit with cochlear implants and to understand the mechanisms, physiological or electronic, that underlie changes in performance. We began our work with cochlear implant patients in the mid-1980s and received our first grant from the National Institutes of Health (NIH) for work with implanted patients in 1989. Since that date our work with cochlear implant patients has been funded continuously by the NIH. In this report we describe some of the research currently being conducted in our laboratory. PMID:22668760
3D optical coherence tomography image registration for guiding cochlear implant insertion
NASA Astrophysics Data System (ADS)
Cheon, Gyeong-Woo; Jeong, Hyun-Woo; Chalasani, Preetham; Chien, Wade W.; Iordachita, Iulian; Taylor, Russell; Niparko, John; Kang, Jin U.
2014-03-01
In cochlear implant surgery, an electrode array is inserted into the cochlear canal to restore hearing to a person who is profoundly deaf or significantly hearing impaired. One critical part of the procedure is the insertion of the electrode array, which looks like a thin wire, into the cochlear canal. Although X-ray or computed tomography (CT) could be used as a reference to evaluate the pathway of the whole electrode array, there is no way to depict the intra-cochlear canal and basal turn intra-operatively to help guide insertion of the electrode array. Optical coherent tomography (OCT) is a highly effective way of visualizing internal structures of cochlea. Swept source OCT (SSOCT) having center wavelength of 1.3 micron and 2D Galvonometer mirrors was used to achieve 7-mm depth 3-D imaging. Graphics processing unit (GPU), OpenGL, C++ and C# were integrated for real-time volumetric rendering simultaneously. The 3D volume images taken by the OCT system were assembled and registered which could be used to guide a cochlear implant. We performed a feasibility study using both dry and wet temporal bones and the result is presented.
The importance of electrically evoked stapedial reflex in cochlear implant.
Andrade, Kelly Cristina Lira de; Leal, Mariana de Carvalho; Muniz, Lilian Ferreira; Menezes, Pedro de Lemos; Albuquerque, Katia Maria Gomes de; Carnaúba, Aline Tenório Lins
2014-01-01
The most important stage in fitting a cochlear implant is the identification of its dynamic range. The use of objective measures, in particular the electrically elicited stapedius reflex, may provide suitable assistence for initial fitting of cochlear implant, especially in children or adult with multiple disorders, because they provide specific values that serve as the basis of early cochlear implant programming. Verify through a review the use of the electrically elicited stapedius reflex threshold during the activation and mapping process of cochlear implant. Bibliographical search on the Pubmed and Bireme plataforms, and also on Medline, LILACS and SciELO databases, with standard searches until September 2012, using specific keywords. For the selection and evaluation of scientific studies found in the search, criterias have been established, considering the following aspects: author, year/location, grade of recommendation/level of evidence, purpose, sample, age, mean age in years, evaluative testing, results and conclusion. Among 7,304 articles found, 7,080 were excluded from the title, 152 from the abstract, 17 from the article reading, 43 were repeated and 12 were selected for the study. The electrically elicited stapedius reflex may support when programming the cochlear implant, especially in patients with inconsistent responses.
The relationship between loudness intensity functions and the click-ABR wave V latency.
Serpanos, Y C; O'Malley, H; Gravel, J S
1997-10-01
To assess the relationship of loudness growth and the click-evoked auditory brain stem response (ABR) wave V latency-intensity function (LIF) in listeners with normal hearing or cochlear hearing loss. The effect of hearing loss configuration on the intensity functions was also examined. Behavioral and electrophysiological intensity functions were obtained using click stimuli of comparable intensities in listeners with normal hearing (Group I; n = 10), and cochlear hearing loss of flat (Group II; n = 10) or sloping (Group III; n = 10) configurations. Individual intensity functions were obtained from measures of loudness growth using the psychophysical methods of absolute magnitude estimation and production of loudness (geometrically averaged to provide the measured loudness function), and from the wave V latency measures of the ABR. Slope analyses for the behavioral and electrophysiological intensity functions were separately performed by group. The loudness growth functions for the groups with cochlear hearing loss approximated the normal function at high intensities, with overall slope values consistent with those reported from previous psychophysical research. The ABR wave V LIF for the group with a flat configuration of cochlear hearing loss approximated the normal function at high intensities, and was displaced parallel to the normal function for the group with sloping configuration. The relationship between the behavioral and electrophysiological intensity functions was examined at individual intensities across the range of the functions for each subject. A significant relationship was obtained between loudness and the ABR wave V LIFs for the groups with normal hearing and flat configuration of cochlear hearing loss; the association was not significant (p = 0.10) for the group with a sloping configuration of cochlear hearing loss. The results of this study established a relationship between loudness and the ABR wave V latency for listeners with normal hearing, and flat cochlear hearing loss. In listeners with a sloping configuration of cochlear hearing loss, the relationship was not significant. This suggests that the click-evoked ABR may be used to estimate loudness growth at least for individuals with normal hearing and those with a flat configuration of cochlear hearing loss. Predictive equations were derived to estimate loudness growth for these groups. The use of frequency-specific stimuli may provide more precise information on the nature of the relationship between loudness growth and the ABR wave V latency, particularly for listeners with sloping configurations of cochlear hearing loss.
[Applied anatomy of scala tympani inlet related to cochlear implantation].
Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping
2012-06-01
To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.
Harris, Jill; Kamke, Marc R
2014-11-01
Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Electrical resistivity measurements in the mammalian cochlea after neural degeneration.
Micco, Alan G; Richter, Claus-Peter
2006-08-01
In the present series of experiments, the effect of neural degeneration on the cochlear structure electrical resistivities was evaluated to test if it alters the current flow in the cochlea and if increased current levels are needed to stimulate the impaired cochlea. In cochlear implants, frequency information is encoded in part by stimulating discrete populations of spiral ganglion cells along the cochlea. However, electrical properties of the cochlear structures result in shunting of the current away from the auditory neurons. This consumes energy, makes cochlear implants less efficient, and drastically reduces battery life. Models of the electrically stimulated cochlea serve to make predictions on current paths using modified and improved cochlear implant electrodes. However, one of the model's shortcomings is that most of the values for tissue impedances are not direct measurements. They are derived from bulk impedance measurements, which are fitted to lumped-element models. The four-electrode reflection-coefficient technique was used to measure resistivities in the gerbil cochlea. In vivo and in vitro (the hemicochlea) models were used. Measurements were made in normal and in deafened animals. Cochlear damage was induced by neomycin injection into the animals' middle ears. Neural degeneration was allowed to occur over 2 months before performing the measurements in the deafened animals. The resistivity values in deafened animals were smaller than in the normal-hearing animals, thus altering the current flow within the cochlea. Resistivity changes and subsequent changes in current path should be considered in future designs of cochlear implants.
Zwolan, Teresa A; O'Sullivan, Mary Beth; Fink, Nancy E; Niparko, John K
2008-02-01
To evaluate mapping characteristics of children with cochlear implants who are enrolled in the Childhood Development After Cochlear Implantation (CDACI) multicenter study. Longitudinal evaluation during 24 months of speech processor maps of children with cochlear implants prospectively enrolled in the study. Six tertiary referral centers. One hundred eighty-eight children enrolled in the CDACI study who were 5 years old or younger at the time of enrollment. Of these children, 184 received unilateral implants, and 4 received simultaneous bilateral implants. Children attended regular mapping sessions at their implant clinic as part of the study protocol. Maps were examined for each subject at 4 different time intervals: at device activation and 6, 12, and 24 months postactivation. Mean C/M levels (in charge per phase) were compared for 4 different time intervals, for 3 different devices, for 6 different implant centers, and for children with normal and abnormal cochleae. All 3 types of implant devices demonstrate significant increases in C/M levels between device activation and the 24-month appointment. Significant differences in mean C/M levels were noted between devices. Children with cochlear anomalies demonstrate significantly greater C/M levels than children with normal cochleae. The CDACI study has enabled us to evaluate the mapping characteristics of pediatric patients who use 3 different devices and were implanted at a variety of implant centers. Analysis of such data enables us to better understand the mapping characteristics of children with cochlear implants.
Geng, Ruishuang; Melki, Sami; Chen, Daniel H.-C.; Tian, Guilian; Furness, David; Oshima-Takago, Tomoko; Neef, Jakob; Moser, Tobias; Askew, Charles; Horwitz, Geoff; Holt, Jeffrey; Imanishi, Yoshikazu; Alagramam, Kumar N.
2012-01-01
Mutation in the clarin-1 gene results in loss of hearing and vision in humans (Usher syndrome III), but the role of clarin-1 in the sensory hair cells is unknown. Clarin-1 is predicted to be a four transmembrane domain protein similar to members of the tetraspanin family. Mice carrying null mutation in the clarin-1 (Clrn1−/−) gene show loss of hair cell function and a possible defect in ribbon synapse. We investigated the role of clarin-1 using various in vitro and in vivo approaches. We show by immunohistochemistry and patch-clamp recordings of Ca2+ currents and membrane capacitance from IHCs that clarin-1 is not essential for formation or function of ribbon synapse. However, reduced cochlear microphonic potentials, FM1-43 loading and transduction currents pointed to diminished cochlear hair bundle function in Clrn1−/− mice. Electron microscopy of cochlear hair cells revealed loss of some tall stereocilia and gaps in the v-shaped bundle, although tip-links and staircase arrangement of stereocilia were not primarily affected by Clrn1−/− mutation. Human clarin-1 protein expressed in transfected mouse cochlear hair cells localized to the bundle; however, the pathogenic variant, p.N48K, failed to localize to the bundle. The mouse model generated to study the in vivo consequence of p. N48K in clarin-1 (Clrn1N48K) supports our in vitro and Clrn1−/− mouse data and the conclusion that CLRN1 is an essential hair bundle protein. Further, the ear phenotype in the Clrn1N48K mouse suggests that it is a valuable model for ear disease in CLRN1N48K, the most prevalent Usher III mutation in North America. PMID:22787034
Geng, Ruishuang; Melki, Sami; Chen, Daniel H-C; Tian, Guilian; Furness, David N; Oshima-Takago, Tomoko; Neef, Jakob; Moser, Tobias; Askew, Charles; Horwitz, Geoff; Holt, Jeffrey R; Imanishi, Yoshikazu; Alagramam, Kumar N
2012-07-11
Mutation in the clarin-1 gene (Clrn1) results in loss of hearing and vision in humans (Usher syndrome III), but the role of clarin-1 in the sensory hair cells is unknown. Clarin-1 is predicted to be a four transmembrane domain protein similar to members of the tetraspanin family. Mice carrying null mutation in the clarin-1 gene (Clrn1(-/-)) show loss of hair cell function and a possible defect in ribbon synapse. We investigated the role of clarin-1 using various in vitro and in vivo approaches. We show by immunohistochemistry and patch-clamp recordings of Ca(2+) currents and membrane capacitance from inner hair cells that clarin-1 is not essential for formation or function of ribbon synapse. However, reduced cochlear microphonic potentials, FM1-43 [N-(3-triethylammoniumpropyl)-4-(4-(dibutylamino)styryl) pyridinium dibromide] loading, and transduction currents pointed to diminished cochlear hair bundle function in Clrn1(-/-) mice. Electron microscopy of cochlear hair cells revealed loss of some tall stereocilia and gaps in the v-shaped bundle, although tip links and staircase arrangement of stereocilia were not primarily affected by Clrn1(-/-) mutation. Human clarin-1 protein expressed in transfected mouse cochlear hair cells localized to the bundle; however, the pathogenic variant p.N48K failed to localize to the bundle. The mouse model generated to study the in vivo consequence of p.N48K in clarin-1 (Clrn1(N48K)) supports our in vitro and Clrn1(-/-) mouse data and the conclusion that CLRN1 is an essential hair bundle protein. Furthermore, the ear phenotype in the Clrn1(N48K) mouse suggests that it is a valuable model for ear disease in CLRN1(N48K), the most prevalent Usher syndrome III mutation in North America.
ERIC Educational Resources Information Center
Mok, Mansze; Grayden, David; Dowell, Richard C.; Lawrence, David
2006-01-01
This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between…
ERIC Educational Resources Information Center
Clark, Catherine
2010-01-01
This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…
ERIC Educational Resources Information Center
Bakar, Zaharah Abu; Brown, P. Margaret; Remine, Maria D.
2010-01-01
This study investigated the potential effects of cochlear implantation and age at implantation on maternal interactional sensitivity. Three groups of dyads were studied at two points over 1 year. The hearing aid (HA) group wore hearing aids throughout the study, the early cochlear implanted (ECI) group were implanted prior to 22 months of age, and…
Inner ear involvement in Behçet's disease.
Süslü, Ahmet Emre; Polat, Mualla; Köybaşi, Serap; Biçer, Yusuf Ozgür; Funda, Yasemin Ongun; Parlak, Ali Haydar
2010-06-01
To assess cochlear involvement and hearing loss in patients with Behçet's disease (BD). Forty-two patients with BD and 24 sex and age matched healthy subjects were included in the study. pure-tone audiometry including high frequencies (250-16000Hz) and DPOAE were performed to all participants. Results of the audiological evaluation were compared and correlation between the audiologic status and clinical manifestations of the BD were investigated. Bilateral sensorineural hearing loss was detected in 27 (64.3%) patients. Hearing thresholds were found to be higher in patients with BD at all of the frequencies except at 500Hz when compared to control group (p<0.05). The difference in the hearing levels tend to increase in high frequencies. Compared with control group, distortion products and SNR of the BD patients were lower in all of the tested frequencies (p<0.05) which indicates weaker outer hair cell motility. There was no correlation between the clinical manifestations and the audiological parameters. Even having hearing levels within normal limits in speech frequencies, increased hearing thresholds in high frequencies and decreased signal-noise ratios (SNR) in distortion product otoacoustic emission (DPOAE) indicate a cochlear involvement in patients with BD. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Werfel, Krystal L; Hendricks, Alison Eisel
2016-01-01
Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits in language and literacy skills; however, the relation between chronic fatigue and language and literacy skills for children with cochlear implants is unclear. The purpose of this study was to explore subjective ratings of chronic fatigue by children with cochlear implants and their parents, as well as the relation between chronic fatigue and language and literacy skills in this population. Nineteen children with cochlear implants in grades 3 to 6 and one of their parents separately completed a subjective chronic fatigue scale, on which they rated how much the child experienced physical, sleep/rest, and cognitive fatigue over the past month. In addition, children completed an assessment battery that included measures of speech perception, oral language, word reading, and spelling. Children and parents reported different levels of chronic child physical and sleep/rest fatigue. In both cases, parents reported significantly less fatigue than did children. Children and parents did not report different levels of chronic child cognitive fatigue. Child report of physical fatigue was related to speech perception, language, reading, and spelling. Child report of sleep/rest and cognitive fatigue was related to speech perception and language but not to reading or spelling. Parent report of child fatigue was not related to children's language and literacy skills. Taken as a whole, results suggested that parents under-estimate the fatigue experienced by children with cochlear implants. Child report of physical fatigue was robustly related to language and literacy skills. Children with cochlear implants are likely more accurate at reporting physical fatigue than cognitive fatigue. Clinical practice should take fatigue into account when developing treatment plans for children with cochlear implants, and research should continue to develop a comprehensive model of fatigue in children with cochlear implants.
Paul, Brandon T; Waheed, Sajal; Bruce, Ian C; Roberts, Larry E
2017-11-01
Noise exposure and aging can damage cochlear synapses required for suprathreshold listening, even when cochlear structures needed for hearing at threshold remain unaffected. To control for effects of aging, behavioral amplitude modulation (AM) detection and subcortical envelope following responses (EFRs) to AM tones in 25 age-restricted (18-19 years) participants with normal thresholds, but different self-reported noise exposure histories were studied. Participants with more noise exposure had smaller EFRs and tended to have poorer AM detection than less-exposed individuals. Simulations of the EFR using a well-established cochlear model were consistent with more synaptopathy in participants reporting greater noise exposure.
Is the Cochlear Amplifier a Fluid Pump?
NASA Astrophysics Data System (ADS)
Karavitaki, K. D.; Mountain, D. C.
2003-02-01
We have visualized and quantified the effects of electrically evoked motility of outer hair cells (OHCs) within the organ of Corti using an excised cochlear preparation. We found that OHC motility induces oscillatory fluid flow in the tunnel of Corti (TC) and this flow is present at physiologically relevant frequencies. We also show, using a simple one-dimensional hydromechanical model of the TC, that a fluid wave within the tunnel can travel without significant attenuation for distances larger than the wavelength of the cochlear traveling wave. These results in combination with a recent hypothesis that fluid flow within the tunnel is necessary for cochlear amplification suggest that the function of the OHCs is to act as a fluid pump.
Imaging cochlear soft tissue displacement with coherent x-rays
NASA Astrophysics Data System (ADS)
Rau, Christoph; Richter, Claus-Peter
2015-10-01
At present, imaging of cochlear mechanics at mid-cochlear turns has not been accomplished. Although challenging, this appears possible with partially coherent hard x-rays. The present study shows results from stroboscopic x-ray imaging of a test object at audio frequencies. The vibration amplitudes were quantified. In a different set of experiments, an intact and calcified gerbil temporal bone was used to determine displacements of the reticular lamina, tectorial membrane, and Reissner’s membrane with the Lucas and Kanade video flow algorithm. The experiments validated high frequency x-ray imaging and imaging in a calcified cochlea. The present work is key for future imaging of cochlear micromechanics at a high spatial resolution.
NASA Astrophysics Data System (ADS)
Verhulst, Sarah; Shera, Christopher A.
2015-12-01
Forward and reverse cochlear latency and its relation to the frequency tuning of the auditory filters can be assessed using tone bursts (TBs). Otoacoustic emissions (TBOAEs) estimate the cochlear roundtrip time, while auditory brainstem responses (ABRs) to the same stimuli aim at measuring the auditory filter buildup time. Latency ratios are generally close to two and controversy exists about the relationship of this ratio to cochlear mechanics. We explored why the two methods provide different estimates of filter buildup time, and ratios with large inter-subject variability, using a time-domain model for OAEs and ABRs. We compared latencies for twenty models, in which all parameters but the cochlear irregularities responsible for reflection-source OAEs were identical, and found that TBOAE latencies were much more variable than ABR latencies. Multiple reflection-sources generated within the evoking stimulus bandwidth were found to shape the TBOAE envelope and complicate the interpretation of TBOAE latency and TBOAE/ABR ratios in terms of auditory filter tuning.
Long latency auditory evoked potentials in children with cochlear implants: systematic review.
Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de
2013-11-25
The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.
Corticofugal modulation of peripheral auditory responses
Terreros, Gonzalo; Delano, Paul H.
2015-01-01
The auditory efferent system originates in the auditory cortex and projects to the medial geniculate body (MGB), inferior colliculus (IC), cochlear nucleus (CN) and superior olivary complex (SOC) reaching the cochlea through olivocochlear (OC) fibers. This unique neuronal network is organized in several afferent-efferent feedback loops including: the (i) colliculo-thalamic-cortico-collicular; (ii) cortico-(collicular)-OC; and (iii) cortico-(collicular)-CN pathways. Recent experiments demonstrate that blocking ongoing auditory-cortex activity with pharmacological and physical methods modulates the amplitude of cochlear potentials. In addition, auditory-cortex microstimulation independently modulates cochlear sensitivity and the strength of the OC reflex. In this mini-review, anatomical and physiological evidence supporting the presence of a functional efferent network from the auditory cortex to the cochlear receptor is presented. Special emphasis is given to the corticofugal effects on initial auditory processing, that is, on CN, auditory nerve and cochlear responses. A working model of three parallel pathways from the auditory cortex to the cochlea and auditory nerve is proposed. PMID:26483647
Müller, Joachim
2005-01-01
Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field. The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies. The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits. PMID:22073052
Müller, Joachim
2005-01-01
Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field.The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies.The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits.
A software tool for analyzing multichannel cochlear implant signals.
Lai, Wai Kong; Bögli, Hans; Dillier, Norbert
2003-10-01
A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.
A phone-assistive device based on Bluetooth technology for cochlear implant users.
Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F
2003-09-01
Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.
Kim, Y R; Yoo, M H; Lee, J Y; Yang, C J; Park, J W; Kang, B C; Kang, W S; Ahn, J H; Chung, J W; Park, H J
2018-05-29
Incidence of facial nerve stimulation (FNS) was 2.8% (32 out of 1151) and higher in ears with cochlear anomaly (6.4%, 25 out of 391) than without cochlear anomaly (0.9%, 7 out of 760). FNS occurred at various current levels and locations of electrodes by different mechanisms related to incomplete insertion of electrodes, cochleo-facial dehiscence, and types of cochlear anomalies. FNS at apical electrodes related to cochleo-facial dehiscence with low current levels, and FNS at basal electrodes with high current levels and partial insertion of electrodes. FNS at most electrodes with high current levels was the most common type in patients with a common cavity or narrowing of the bony cochlear nerve canal. Understanding the mechanisms of FNS might provide insight for preventing FNS when performing CI surgeries. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Cochlear implantation in Waardenburg syndrome: The Indian scenario.
Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani
2010-10-01
Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.
Libyan cochlear implant programme: achievements, difficulties, and future goals
Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya
2011-01-01
Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies. PMID:21694783
Libyan cochlear implant programme: achievements, difficulties, and future goals.
Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya
2011-01-01
Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.
Non-ototoxic local delivery of bisphosphonate to the mammalian cochlea
Kang, Woo Seok; Sun, Shuting; Nguyen, Kim; Kashemirov, Boris; McKenna, Charles E.; Hacking, S. Adam; Quesnel, Alicia M.; Sewell, William F.; McKenna, Michael J.; Jung, David H.
2015-01-01
Hypothesis Local delivery of bisphosphonates results in superior localization of these compounds for the treatment of cochlear otosclerosis, without ototoxicity. Background Otosclerosis is a common disorder of abnormal bone remodeling within the human otic capsule. It is a frequent cause of conductive hearing loss from stapes fixation. Large lesions that penetrate the cochlear endosteum and injure the spiral ligament result in sensorineural hearing loss. Nitrogen-containing bisphosphonates (e.g., zoledronate) are potent inhibitors of bone remodeling with proven efficacy in the treatment of metabolic bone diseases, including otosclerosis. Local delivery to the cochlea may allow for improved drug targeting, higher local concentrations, and the avoidance of systemic complications. In this study, we utilize a fluorescently labeled bisphosphonate compound (6-FAM-ZOL) to determine drug localization and concentration within the otic capsule. Various methods for delivery are compared. Ototoxicity is evaluated by ABR and DPOAEs. Methods 6-FAM-ZOL was administered to guinea pigs via intraperitoneal injection, placement of alginate beads onto the round window membrane (RWM), or microfluidic pump infusion via a cochleostomy. Hearing was evaluated. Specimens were embedded into resin blocks, ground to a mid-modiolar section, and quantitatively imaged using fluorescence microscopy. Results There was a dose-dependent increase in fluorescent signal following systemic 6-FAM-ZOL treatment. Local delivery via the RWM or a cochleostomy increased delivery efficiency. No significant ototoxicity was observed following either systemic or local 6-FAM-ZOL delivery. Conclusions These findings establish important pre-clinical parameters for the treatment of cochlear otosclerosis in humans. PMID:25996080
Effect of Bluetooth headset and mobile phone electromagnetic fields on the human auditory nerve.
Mandalà, Marco; Colletti, Vittorio; Sacchetto, Luca; Manganotti, Paolo; Ramat, Stefano; Marcocci, Alessandro; Colletti, Liliana
2014-01-01
The possibility that long-term mobile phone use increases the incidence of astrocytoma, glioma and acoustic neuroma has been investigated in several studies. Recently, our group showed that direct exposure (in a surgical setting) to cell phone electromagnetic fields (EMFs) induces deterioration of auditory evoked cochlear nerve compound action potential (CNAP) in humans. To verify whether the use of Bluetooth devices reduces these effects, we conducted the present study with the same experimental protocol. Randomized trial. Twelve patients underwent retrosigmoid vestibular neurectomy to treat definite unilateral Ménière's disease while being monitored with acoustically evoked CNAPs to assess direct mobile phone exposure or alternatively the EMF effects of Bluetooth headsets. We found no short-term effects of Bluetooth EMFs on the auditory nervous structures, whereas direct mobile phone EMF exposure confirmed a significant decrease in CNAPs amplitude and an increase in latency in all subjects. The outcomes of the present study show that, contrary to the finding that the latency and amplitude of CNAPs are very sensitive to EMFs produced by the tested mobile phone, the EMFs produced by a common Bluetooth device do not induce any significant change in cochlear nerve activity. The conditions of exposure, therefore, differ from those of everyday life, in which various biological tissues may reduce the EMF affecting the cochlear nerve. Nevertheless, these novel findings may have important safety implications. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Auditory Spatial Perception: Auditory Localization
2012-05-01
cochlear nucleus, TB – trapezoid body, SOC – superior olivary complex, LL – lateral lemniscus, IC – inferior colliculus. Adapted from Aharonson and...Figure 5. Auditory pathways in the central nervous system. LE – left ear, RE – right ear, AN – auditory nerve, CN – cochlear nucleus, TB...fibers leaving the left and right inner ear connect directly to the synaptic inputs of the cochlear nucleus (CN) on the same (ipsilateral) side of
Low Level Chemical Toxicity: Relevance to Chemical Agent Defense
2005-07-01
elevation in stress hormones in the blood serum. Electron microscropy indicated no damage to cochlear tissues of the ear (not shown). At the...neural activity occurring primarily in the cochlear nucleus of the brainstem auditory pathway. Peak II is usually the last major peak to disappear...IV). Peak II is generally the strongest peak and is regarded as a putative indicator of neural activity occurring primarily in the cochlear nucleus
Sex Difference in Susceptibility and Resistance to Noise-Induced Hearing Loss in Chinchillas
2000-10-01
Estradiol assays Blood samples were collected from deeply anesthetized chinchillas prior to cochlear histology. The blood samples were centrifuged to...pattern of hearing loss and cochlear damage for male and female chinchillas Gender differences have been reported in susceptibility to NIHL, both...Given the results of physiological testing (IC-EVPs and CDPs), the results of cochlear histology were somewhat surprising (see McFadden et al., 1999
Di Stadio, Arianna; Colangeli, Roberta; Dipietro, Laura; Martini, Alessandro; Parrino, Daniela; Nardello, Ennio; D'Avella, Domenico; Zanoletti, Elisabetta
2018-05-01
The use of surgical cochlear nerve decompression is controversial. This study aimed at investigating the safety and validity of microsurgical decompression via an endoscope-assisted retrosigmoid approach to treat tinnitus in patients with neurovascular compression of the cochlear nerve. Three patients with disabling tinnitus resulting from a loop in the internal auditory canal were evaluated with magnetic resonance imaging and tests of pure tone auditory, tinnitus, and auditory brain response (ABR) to identify the features of the cochlear nerve involvement. We observed a loop with a caliber greater than 0.8 mm in all patients. Patients were treated via an endoscope-assisted retrosigmoid microsurgical decompression. After surgery, none of the patients reported short-term or long-term complications. After surgery, tinnitus resolved immediately in 2 patients, whereas in the other patient symptoms persisted although they improved; in all patients, hearing was preserved and ABR improved. Microsurgical decompression via endoscope-assisted retrosigmoid approach is a promising, safe, and valid procedure for treating tinnitus caused by cochlear nerve compression. This procedure should be considered in patients with disabling tinnitus who have altered ABR and a loop that has a caliber greater than 0.8 mm and is in contact with the cochlear nerve. Copyright © 2018 Elsevier Inc. All rights reserved.
Inner-ear sound pressures near the base of the cochlea in chinchilla: Further investigation
Ravicz, Michael E.; Rosowski, John J.
2013-01-01
The middle-ear pressure gain GMEP, the ratio of sound pressure in the cochlear vestibule PV to sound pressure at the tympanic membrane PTM, is a descriptor of middle-ear sound transfer and the cochlear input for a given stimulus in the ear canal. GMEP and the cochlear partition differential pressure near the cochlear base ΔPCP, which determines the stimulus for cochlear partition motion and has been linked to hearing ability, were computed from simultaneous measurements of PV, PTM, and the sound pressure in scala tympani near the round window PST in chinchilla. GMEP magnitude was approximately 30 dB between 0.1 and 10 kHz and decreased sharply above 20 kHz, which is not consistent with an ideal transformer or a lossless transmission line. The GMEP phase was consistent with a roughly 50-μs delay between PV and PTM. GMEP was little affected by the inner-ear modifications necessary to measure PST. GMEP is a good predictor of ΔPCP at low and moderate frequencies where PV ⪢ PST but overestimates ΔPCP above a few kilohertz where PV ≈ PST. The ratio of PST to PV provides insight into the distribution of sound pressure within the cochlear scalae. PMID:23556590
Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants
Azimi, Behnam; Hu, Yi; Friedland, David R.
2012-01-01
To restore hearing sensation, cochlear implants deliver electrical pulses to the auditory nerve by relying on sophisticated signal processing algorithms that convert acoustic inputs to electrical stimuli. Although individuals fitted with cochlear implants perform well in quiet, in the presence of background noise, the speech intelligibility of cochlear implant listeners is more susceptible to background noise than that of normal hearing listeners. Traditionally, to increase performance in noise, single-microphone noise reduction strategies have been used. More recently, a number of approaches have suggested that speech intelligibility in noise can be improved further by making use of two or more microphones, instead. Processing strategies based on multiple microphones can better exploit the spatial diversity of speech and noise because such strategies rely mostly on spatial information about the relative position of competing sound sources. In this article, we identify and elucidate the most significant theoretical aspects that underpin single- and multi-microphone noise reduction strategies for cochlear implants. More analytically, we focus on strategies of both types that have been shown to be promising for use in current-generation implant devices. We present data from past and more recent studies, and furthermore we outline the direction that future research in the area of noise reduction for cochlear implants could follow. PMID:22923425
Arpornchayanon, Warangkana; Canis, Martin; Ihler, Friedrich; Settevendemie, Claudia; Strieth, Sebastian
2013-08-01
Exposure to loud noise can impair cochlear microcirculation and cause noise-induced hearing loss (NIHL). TNF-α signaling has been shown to be activated in NIHL and to control spiral modiolar artery vasoconstriction that regulates cochlear microcirculation. It was the aim of this experimental study to analyse the effects of the TNF-α inhibitor etanercept on cochlear microcirculation and hearing threshold shift in NIHL in vivo. After assessment of normacusis using ABR, loud noise (106 dB SPL, 30 minutes) was applied on both ears in guinea pigs. Etanercept was administered systemically after loud noise exposure while control animals received a saline solution. In vivo fluorescence microscopy of strial capillaries was performed after surgical exposure of the cochlea for microcirculatory analysis. ABR measurements were derived from the contralateral ear. Guinea pigs (n = 6, per group). Compared to controls, cochlear blood flow in strial capillary segments was significantly increased in etanercept-treated animals. Additionally, hearing threshold was preserved in animals receiving the TNF-α inhibitor in contrast to a significant threshold raising in controls. TNF-α inhibition using etanercept improves cochlear microcirculation and protects hearing levels after loud noise exposure and appears as a promising treatment strategy for human NIHL.
Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D
2016-02-01
To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.
Mandal, Joyanta Chandra; Kumar, Suman; Roy, Sumit
2016-12-01
The main goal of this study was to obtain auditory comprehension skills of native Hindi speaking children with cochlear implant and typically developing children across the age of 3-7 years and compare the scores between two groups. A total of sixty Hindi speaking participants were selected for the study. They were divided into two groups- Group-A consisted of thirty children with normal hearing and Group-B thirty children using cochlear implants. To assess the auditory comprehension skills, Test of auditory comprehension in Hindi (TACH) was used. The participant was required to point to one of three pictures which would best correspond to the stimulus presented. Correct answers were scored as 1 and incorrect answers as 0. TACH was administered on for both groups. Independent t-test was applied and it was found that auditory comprehension scores of children using cochlear implant were significantly poorer than the score of children with normal hearing for all three subtests. Pearson's correlation coefficient revealed poor correlation between the scores of children with normal hearing and children using cochlear implant. The results of this study suggest that children using cochlear implant have poor auditory comprehension skills than children with normal hearing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.
Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan
2015-02-01
To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.
Cochlear implanted pupils in Scottish schools: 4-year school attainment data (2000-2004).
Thoutenhoofd, Ernst
2006-01-01
The Achievements of Deaf Pupils in Scotland (ADPS) project has been tracking the educational attainment of deaf pupils in Scotland's schools since 2000. At the time of writing, the database contains records for 1,752 deaf pupils (2000-2005). Here 4-year aggregate educational attainment data are reported for a subset of 152 school-aged deaf pupils with cochlear implants notified to the ADPS database between June 2000 and June 2004. The data describe primary and secondary school results in reading, writing, and math for this subgroup, as well as placement and communication characteristics. The educational attainment of the group of deaf pupils with cochlear implants is clearly marked when the deaf pupil population is disaggregated for hearing loss, achieving comparatively higher average attainment in both 5-14 Curriculum National Tests (Mathematics in particular) and Standard Grades. Therefore the gap in performance relative to the national population data is reduced for those deaf pupils, although it still widens at higher levels of achievement for the National Tests. Although most pupils with cochlear implants are placed in the mainstream, there is no pattern of migration toward mainstream schools. Some deaf pupils with cochlear implants moved out of mainstream to other types of placement, and this has implications for health-economic cost-utility assessments of cochlear implantation that favor mainstream education by drawing upon the relative cost of different placement types. These findings suggest that the ADPS program of research can contribute school outcome data as valuable real-life outcome measures in wider assessments of the benefit of cochlear implants to deaf children and deaf young people.
Musical experience sharpens human cochlear tuning.
Bidelman, Gavin M; Nelms, Caitlin; Bhagat, Shaum P
2016-05-01
The mammalian cochlea functions as a filter bank that performs a spectral, Fourier-like decomposition on the acoustic signal. While tuning can be compromised (e.g., broadened with hearing impairment), whether or not human cochlear frequency resolution can be sharpened through experiential factors (e.g., training or learning) has not yet been established. Previous studies have demonstrated sharper psychophysical tuning curves in trained musicians compared to nonmusicians, implying superior peripheral tuning. However, these findings are based on perceptual masking paradigms, and reflect engagement of the entire auditory system rather than cochlear tuning, per se. Here, by directly mapping physiological tuning curves from stimulus frequency otoacoustic emissions (SFOAEs)-cochlear emitted sounds-we show that estimates of human cochlear tuning in a high-frequency cochlear region (4 kHz) is further sharpened (by a factor of 1.5×) in musicians and improves with the number of years of their auditory training. These findings were corroborated by measurements of psychophysical tuning curves (PTCs) derived via simultaneous masking, which similarly showed sharper tuning in musicians. Comparisons between SFOAE and PTCs revealed closer correspondence between physiological and behavioral curves in musicians, indicating that tuning is also more consistent between different levels of auditory processing in trained ears. Our findings demonstrate an experience-dependent enhancement in the resolving power of the cochlear sensory epithelium and the spectral resolution of human hearing and provide a peripheral account for the auditory perceptual benefits observed in musicians. Both local and feedback (e.g., medial olivocochlear efferent) mechanisms are discussed as potential mechanisms for experience-dependent tuning. Copyright © 2016 Elsevier B.V. All rights reserved.
Using Evoked Potentials to Match Interaural Electrode Pairs with Bilateral Cochlear Implants
Delgutte, Bertrand
2007-01-01
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency–channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable. PMID:17225976
Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants.
Smith, Zachary M; Delgutte, Bertrand
2007-03-01
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency-channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable.
Prenzler, Nils K; Salcher, Rolf; Timm, Max; Gaertner, Lutz; Lenarz, Thomas; Warnecke, Athanasia
2018-05-14
Suppression of foreign body reaction, improvement of electrode-nerve interaction, and preservation of residual hearing are essential research topics in cochlear implantation. Intracochlear pharmaco- or cell-based therapies can open new horizons in this field. Local drug delivery strategies are desirable as higher local concentrations of agents can be realized and side effects can be minimized compared to systemic administrations. When administered locally at accessible, basal parts of the cochlea, drugs reach apical regions later and in much lower concentrations due to poor diffusion patterns in cochlear fluids. Therefore, new devices are needed to warrant rapid distribution of agents into all parts of the cochlea. Five patients received a deep intracochlear injection of triamcinolone with a specifically designed cochlear catheter during cochlear implantation right before inserting a cochlear implant electrode. As a measure for formation of fibrous tissue around the electrode, electrical impedances were measured in the operation room and over 4 months thereafter. No adverse events were observed peri- and postoperatively. The handling of the device was easy. Severe damage to the microstructure of the cochlea was excluded as far as possible by cone beam computed tomography and vestibular testing. A delayed rise of the impedances was seen in the catheter group compared to controls over all regions of the cochlea. A statistical significance, however, was only obtained at the midregion of the cochlea. Consequently, the cochlear catheter is a safe and feasible device for local drug delivery of pharmaceutical agents into deeper regions of the cochlea.
Dietz, Mathias; Hohmann, Volker; Jürgens, Tim
2015-01-01
For normal-hearing listeners, speech intelligibility improves if speech and noise are spatially separated. While this spatial release from masking has already been quantified in normal-hearing listeners in many studies, it is less clear how spatial release from masking changes in cochlear implant listeners with and without access to low-frequency acoustic hearing. Spatial release from masking depends on differences in access to speech cues due to hearing status and hearing device. To investigate the influence of these factors on speech intelligibility, the present study measured speech reception thresholds in spatially separated speech and noise for 10 different listener types. A vocoder was used to simulate cochlear implant processing and low-frequency filtering was used to simulate residual low-frequency hearing. These forms of processing were combined to simulate cochlear implant listening, listening based on low-frequency residual hearing, and combinations thereof. Simulated cochlear implant users with additional low-frequency acoustic hearing showed better speech intelligibility in noise than simulated cochlear implant users without acoustic hearing and had access to more spatial speech cues (e.g., higher binaural squelch). Cochlear implant listener types showed higher spatial release from masking with bilateral access to low-frequency acoustic hearing than without. A binaural speech intelligibility model with normal binaural processing showed overall good agreement with measured speech reception thresholds, spatial release from masking, and spatial speech cues. This indicates that differences in speech cues available to listener types are sufficient to explain the changes of spatial release from masking across these simulated listener types. PMID:26721918
Gwon, Tae Mok; Min, Kyou Sik; Kim, Jin Ho; Oh, Seung Ha; Lee, Ho Sun; Park, Min-Hyun; Kim, Sung June
2015-04-01
An atraumatic cochlear electrode array has become indispensable to high-performance cochlear implants such as electric acoustic stimulation (EAS), wherein the preservation of residual hearing is significant. For an atraumatic implantation, we propose and demonstrate a new improved design of a cochlear electrode array based on liquid crystal polymer (LCP), which can be fabricated by precise batch processes and a thermal lamination process, in contrast to conventional wire-based cochlear electrode arrays. Using a thin-film process of LCP-film-mounted silicon wafer and thermal press lamination, we devise a multi-layered structure with variable layers of LCP films to achieve a sufficient degree of basal rigidity and a flexible tip. A peripheral blind via and self-aligned silicone elastomer molding process can reduce the width of the array. Measuring the insertion and extraction forces in a human scala tympani model, we investigate five human temporal bone insertion trials and record electrically evoked auditory brainstem responses (EABR) acutely in a guinea pig model. The diameters of the finalized electrode arrays are 0.3 mm (tip) and 0.75 mm (base). The insertion force with a displacement of 8 mm from a round window and the maximum extraction force are 2.4 mN and 34.0 mN, respectively. The electrode arrays can be inserted from 360° to 630° without trauma at the basal turn. The EABR data confirm the efficacy of the array. A new design of LCP-based cochlear electrode array for atraumatic implantation is fabricated. Verification indicates that foretells the development of an atraumatic cochlear electrode array and clinical implant.
Ross, Astin M.; Rahmani, Sahar; Prieskorn, Diane M.; Dishman, Acacia F; Miller, Josef M.; Lahann, Joerg; Altschuler, Richard A.
2016-01-01
Delivery of pharmaceuticals to the cochleae of patients with auditory dysfunction could potentially have many benefits from enhancing auditory nerve survival to protecting remaining sensory cells and their neuronal connections. Treatment would require platforms to enable drug delivery directly to the cochlea and increase the potential efficacy of intervention. Cochlear implant recipients are a specific patient subset that could benefit from local drug delivery as more candidates have residual hearing; and since residual hearing directly contributes to post-implantation hearing outcomes, it requires protection from implant insertion-induced trauma. This study assessed the feasibility of utilizing microparticles for drug delivery into cochlear fluids, testing persistence, distribution, biocompatibility, and drug release characteristics. To allow for delivery of multiple therapeutics, particles were composed of two distinct compartments; one containing polylactide-co-glycolide (PLGA), and one composed of acetal-modified dextran and PLGA. Following in vivo infusion, image analysis revealed microparticle persistence in the cochlea for at least 7 days post-infusion, primarily in the first and second turns. The majority of subjects maintained or had only slight elevation in auditory brainstem response thresholds at 7 days post-infusion compared to pre-infusion baselines. There was only minor to limited loss of cochlear hair cells and negligible immune response based on CD45+ immunolabling. When Piribedil-loaded microparticles were infused, Piribedil was detectable within the cochlear fluids at 7 days post-infusion. These results indicate that segmented microparticles are relatively inert, can persist, release their contents, and be functionally and biologically compatible with cochlear function and therefore are promising vehicles for cochlear drug delivery. PMID:26841263
Prevention and management of vascular complications in middle ear and cochlear implant surgery.
Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo
2017-11-01
The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.
Wang, Ping; Li, Haonan; Yu, Shuyuan; Jin, Peng; Hassan, Abdurahman; Du, Bo
2017-08-24
This study aimed to elucidate the protective effect of minocycline against streptomycin-induced damage of cochlear hair cells and its mechanism. Cochlear membranes were isolated from newborn Wistar rats and randomly divided into control, 500μmol/L streptomycin, 100μmol/L minocycline, and streptomycin and minocycline treatment groups. Hair cell survival was analyzed by detecting the expression of 3-nitrotyrosine (3-NT) in cochlear hair cells by immunofluorescence and an enzyme-linked immunosorbent assay. Expression of 3-NT and inducible nitric oxide synthase (iNOS), and poly (ADP-Ribose) polymerase (PARP) and caspase-3 activation were evaluated by western blotting. The results demonstrated hair cell loss at 24h after streptomycin treatment. No change was found in supporting cells of the cochleae. Minocycline pretreatment improved hair cell survival and significantly reduced the expression of iNOS and 3-NT in cochlear tissues compared with the streptomycin treatment group. PARP and caspase-3 activation was increased in the streptomycin treatment group compared with the control group, and pretreatment with minocycline decreased cleaved PARP and activated caspase-3 expression. Minocycline protected cochlear hair cells from injury caused by streptomycin in vitro. The mechanism underlying the protective effect may be associated with the inhibition of excessive formation of nitric oxide, reduction of the nitration stress reaction, and inhibition of PARP and caspase-3 activation in cochlear hair cells. Combined minocycline therapy can be applied to patients requiring streptomycin treatment. Copyright © 2017. Published by Elsevier B.V.
Plontke, Stefan K; Kösling, Sabrina; Rahne, Torsten
2018-03-01
To describe the technique for surgical tumor removal, cochlear implant (CI) electrode placement and reconstruction of the surgical defect in patients with intracochlear schwannomas. Retrospective case review. Tertiary referral center. Ten patients (five men, five women, mean age 48 ± 12 yr) with profound or severe to profound hearing loss due to intralabyrinthine schwannomas with intracochlear location. Surgical tumor removal through extended round window approach, partial or subtotal cochleoectomy with or without labyrinthectomy and reconstruction of the surgical defect with cartilage, perichondrium or temporal muscle fascia, and bone pâté. Eight patients received a cochlear implant in the same procedure. Retrospective evaluation of clinical outcome including safety aspects (adverse events) and audiological performance at early follow up in cases of cochlear implantation. The tumor was successfully removed in all cases without macroscopic (operation microscope and endoscope) tumor remnants in the bony labyrinth apart from one case with initial transmodiolar growth. One patient needed revision surgery for labyrinthine fistula. At short-term follow up (3-month post-surgery), good hearing results with the cochlear implant were obtained in all but one patient with a word recognition score of 100% for numbers, and 64 ± 14% for monosyllables (at 65 dB SPL in quiet). Surgical tumor removal and cochlear implantation is a promising treatment strategy in the management of intralabyrinthine schwannoma with intracochlear location, further extending the indication range for cochlear implantation. It is, however, of importance to observe the long-term outcome in these patients and to address challenges like follow up with magnetic resonance imaging.
Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.
Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O
2013-06-01
To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is <90°, there is no demagnetisation; if the bi/b0 angle is >90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.
Distortion products in auditory fMRI research: Measurements and solutions.
Norman-Haignere, Sam; McDermott, Josh H
2016-04-01
Nonlinearities in the cochlea can introduce audio frequencies that are not present in the sound signal entering the ear. Known as distortion products (DPs), these added frequencies complicate the interpretation of auditory experiments. Sound production systems also introduce distortion via nonlinearities, a particular concern for fMRI research because the Sensimetrics earphones widely used for sound presentation are less linear than most high-end audio devices (due to design constraints). Here we describe the acoustic and neural effects of cochlear and earphone distortion in the context of fMRI studies of pitch perception, and discuss how their effects can be minimized with appropriate stimuli and masking noise. The amplitude of cochlear and Sensimetrics earphone DPs were measured for a large collection of harmonic stimuli to assess effects of level, frequency, and waveform amplitude. Cochlear DP amplitudes were highly sensitive to the absolute frequency of the DP, and were most prominent at frequencies below 300 Hz. Cochlear DPs could thus be effectively masked by low-frequency noise, as expected. Earphone DP amplitudes, in contrast, were highly sensitive to both stimulus and DP frequency (due to prominent resonances in the earphone's transfer function), and their levels grew more rapidly with increasing stimulus level than did cochlear DP amplitudes. As a result, earphone DP amplitudes often exceeded those of cochlear DPs. Using fMRI, we found that earphone DPs had a substantial effect on the response of pitch-sensitive cortical regions. In contrast, cochlear DPs had a small effect on cortical fMRI responses that did not reach statistical significance, consistent with their lower amplitudes. Based on these findings, we designed a set of pitch stimuli optimized for identifying pitch-responsive brain regions using fMRI. These stimuli robustly drive pitch-responsive brain regions while producing minimal cochlear and earphone distortion, and will hopefully aid fMRI researchers in avoiding distortion confounds. Copyright © 2016 Elsevier Inc. All rights reserved.
Spoken language development in children following cochlear implantation.
Niparko, John K; Tobey, Emily A; Thal, Donna J; Eisenberg, Laurie S; Wang, Nae-Yuh; Quittner, Alexandra L; Fink, Nancy E
2010-04-21
Cochlear implantation is a surgical alternative to traditional amplification (hearing aids) that can facilitate spoken language development in young children with severe to profound sensorineural hearing loss (SNHL). To prospectively assess spoken language acquisition following cochlear implantation in young children. Prospective, longitudinal, and multidimensional assessment of spoken language development over a 3-year period in children who underwent cochlear implantation before 5 years of age (n = 188) from 6 US centers and hearing children of similar ages (n = 97) from 2 preschools recruited between November 2002 and December 2004. Follow-up completed between November 2005 and May 2008. Performance on measures of spoken language comprehension and expression (Reynell Developmental Language Scales). Children undergoing cochlear implantation showed greater improvement in spoken language performance (10.4; 95% confidence interval [CI], 9.6-11.2 points per year in comprehension; 8.4; 95% CI, 7.8-9.0 in expression) than would be predicted by their preimplantation baseline scores (5.4; 95% CI, 4.1-6.7, comprehension; 5.8; 95% CI, 4.6-7.0, expression), although mean scores were not restored to age-appropriate levels after 3 years. Younger age at cochlear implantation was associated with significantly steeper rate increases in comprehension (1.1; 95% CI, 0.5-1.7 points per year younger) and expression (1.0; 95% CI, 0.6-1.5 points per year younger). Similarly, each 1-year shorter history of hearing deficit was associated with steeper rate increases in comprehension (0.8; 95% CI, 0.2-1.2 points per year shorter) and expression (0.6; 95% CI, 0.2-1.0 points per year shorter). In multivariable analyses, greater residual hearing prior to cochlear implantation, higher ratings of parent-child interactions, and higher socioeconomic status were associated with greater rates of improvement in comprehension and expression. The use of cochlear implants in young children was associated with better spoken language learning than would be predicted from their preimplantation scores.
Distortion Products in Auditory fMRI Research: Measurements and Solutions
Norman-Haignere, Sam; McDermott, Josh H.
2016-01-01
Nonlinearities in the cochlea can introduce audio frequencies that are not present in the sound signal entering the ear. Known as distortion products (DPs), these added frequencies complicate the interpretation of auditory experiments. Sound production systems also introduce distortion via nonlinearities, a particular concern for fMRI research because the Sensimetrics earphones widely used for sound presentation are less linear than most high-end audio devices (due to design constraints). Here we describe the acoustic and neural effects of cochlear and earphone distortion in the context of fMRI studies of pitch perception, and discuss how their effects can be minimized with appropriate stimuli and masking noise. The amplitude of cochlear and Sensimetrics earphone DPs were measured for a large collection of harmonic stimuli to assess effects of level, frequency, and waveform amplitude. Cochlear DP amplitudes were highly sensitive to the absolute frequency of the DP, and were most prominent at frequencies below 300 Hz. Cochlear DPs could thus be effectively masked by low-frequency noise, as expected. Earphone DP amplitudes, in contrast, were highly sensitive to both stimulus and DP frequency (due to prominent resonances in the earphone’s transfer function), and their levels grew more rapidly with increasing stimulus level than did cochlear DP amplitudes. As a result, earphone DP amplitudes often exceeded those of cochlear DPs. Using fMRI, we found that earphone DPs had a substantial effect on the response of pitch-sensitive cortical regions. In contrast, cochlear DPs had a small effect on cortical fMRI responses that did not reach statistical significance, consistent with their lower amplitudes. Based on these findings, we designed a set of pitch stimuli optimized for identifying pitch-responsive brain regions using fMRI. These stimuli robustly drive pitch-responsive brain regions while producing minimal cochlear and earphone distortion, and will hopefully aid fMRI researchers in avoiding distortion confounds. PMID:26827809
Experiences from Auditory Brainstem Implantation (ABIs) in four paediatric patients.
Lundin, Karin; Stillesjö, Fredrik; Nyberg, Gunnar; Rask-Andersen, Helge
2016-01-01
Indications for auditory brainstem implants (ABIs) have been widened from patients with neurofibromatosis type 2 (NF2) to paediatric patients with congenital cochlear malformations, cochlear nerve hypoplasia/aplasia, or cochlear ossification after meningitis. We present four ABI surgeries performed in children at Uppsala University Hospital in Sweden since 2009. Three children were implanted with implants from Cochlear Ltd. (Lane Cove, Australia) and one child with an implant from MedEl GMBH (Innsbruck, Austria). A boy with Goldenhar syndrome was implanted with a Cochlear Nucleus ABI24M at age 2 years (patient 1). Another boy with CHARGE syndrome was implanted with a Cochlear Nucleus ABI541 at age 2.5 years (patient 2). Another boy with post-ossification meningitis was implanted with a Cochlear Nucleus ABI24M at age 4 years (patient 3). A girl with cochlear aplasia was implanted with a MedEl Synchrony ABI at age 3 years (patient 4). In patients 1, 2, and 3, the trans-labyrinthine approach was used, and in patient 4 the retro-sigmoid approach was used. Three of the four children benefited from their ABIs and use it full time. Two of the full time users had categories of auditory performance (CAP) score of 4 at their last follow up visit (6 and 2.5 years postoperative) which means they can discriminate consistently any combination of two of Ling's sounds. One child has not been fully evaluated yet, but is a full time user and had CAP 2 (responds to speech sounds) after 3 months of ABI use. No severe side or unpleasant stimulation effects have been observed so far. There was one case of immediate electrode migration and one case of implant device failure after 6.5 years. ABI should be considered as an option in the rehabilitation of children with similar diagnoses.
Cochlear implantation in adults with asymmetric hearing loss.
Firszt, Jill B; Holden, Laura K; Reeder, Ruth M; Cowdrey, Lisa; King, Sarah
2012-01-01
Bilateral severe to profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the nonimplanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe to profound hearing loss in one ear and a more moderate hearing loss in the other ear (i.e., asymmetric hearing) are not typically considered candidates for cochlear implantation. Amplification in the poorer ear is often unsuccessful because of limited benefit, restricting the patient to unilateral listening from the better ear alone. The purpose of this study was to determine whether patients with asymmetric hearing loss could benefit from cochlear implantation in the poorer ear with continued use of a hearing aid in the better ear. Ten adults with asymmetric hearing between ears participated. In the poorer ear, all participants met cochlear implant candidacy guidelines; seven had postlingual onset, and three had pre/perilingual onset of severe to profound hearing loss. All had open-set speech recognition in the better-hearing ear. Assessment measures included word and sentence recognition in quiet, sentence recognition in fixed noise (four-talker babble) and in diffuse restaurant noise using an adaptive procedure, localization of word stimuli, and a hearing handicap scale. Participants were evaluated preimplant with hearing aids and postimplant with the implant alone, the hearing aid alone in the better ear, and bimodally (the implant and hearing aid in combination). Postlingual participants were evaluated at 6 mo postimplant, and pre/perilingual participants were evaluated at 6 and 12 mo postimplant. Data analysis compared the following results: (1) the poorer-hearing ear preimplant (with hearing aid) and postimplant (with cochlear implant); (2) the device(s) used for everyday listening pre- and postimplant; and (3) the hearing aid-alone and bimodal listening conditions postimplant. The postlingual participants showed significant improvements in speech recognition after 6 mo cochlear implant use in the poorer ear. Five postlingual participants had a bimodal advantage over the hearing aid-alone condition on at least one test measure. On average, the postlingual participants had significantly improved localization with bimodal input compared with the hearing aid-alone. Only one pre/perilingual participant had open-set speech recognition with the cochlear implant. This participant had better hearing than the other two pre/perilingual participants in both the poorer and better ear. Localization abilities were not significantly different between the bimodal and hearing aid-alone conditions for the pre/perilingual participants. Mean hearing handicap ratings improved postimplant for all participants indicating perceived benefit in everyday life with the addition of the cochlear implant. Patients with asymmetric hearing loss who are not typical cochlear implant candidates can benefit from using a cochlear implant in the poorer ear with continued use of a hearing aid in the better ear. For this group of 10, the 7 postlingually deafened participants showed greater benefits with the cochlear implant than the pre/perilingual participants; however, further study is needed to determine maximum benefit for those with early onset of hearing loss.
Cochlear Implantation in Adults with Asymmetric Hearing Loss
Firszt, Jill B.; Holden, Laura K.; Reeder, Ruth M.; Cowdrey, Lisa; King, Sarah
2012-01-01
Objective Bilateral severe-to-profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the non-implanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe-to-profound hearing loss in one ear and a more moderate hearing loss in the other ear (i.e., asymmetric hearing) are not typically considered candidates for cochlear implantation. Amplification in the poorer ear is often unsuccessful due to limited benefit, restricting the patient to unilateral listening from the better ear alone. The purpose of this study was to determine if patients with asymmetric hearing loss could benefit from cochlear implantation in the poorer ear with continued use of a hearing aid in the better ear. Design Ten adults with asymmetric hearing between ears participated. In the poorer ear, all participants met cochlear implant candidacy guidelines; seven had postlingual onset and three had pre/perilingual onset of severe-to-profound hearing loss. All had open-set speech recognition in the better hearing ear. Assessment measures included word and sentence recognition in quiet, sentence recognition in fixed noise (four-talker babble) and in diffuse restaurant noise using an adaptive procedure, localization of word stimuli and a hearing handicap scale. Participants were evaluated pre-implant with hearing aids and post-implant with the implant alone, the hearing aid alone in the better ear and bimodally (the implant and hearing aid in combination). Postlingual participants were evaluated at six months post-implant and pre/perilingual participants were evaluated at six and 12 months post-implant. Data analysis compared results 1) of the poorer hearing ear pre-implant (with hearing aid) and post-implant (with cochlear implant), 2) with the device(s) used for everyday listening pre- and post-implant and, 3) between the hearing aid-alone and bimodal listening conditions post-implant. Results The postlingual participants showed significant improvements in speech recognition after six months cochlear implant use in the poorer ear. Five postlingual participants had a bimodal advantage over the hearing aid-alone condition on at least one test measure. On average, the postlingual participants had significantly improved localization with bimodal input compared to the hearing aid-alone. Only one pre/perilingual participant had open-set speech recognition with the cochlear implant. This participant had better hearing than the other two pre/perilingual participants in both the poorer and better ear. Localization abilities were not significantly different between the bimodal and hearing aid-alone conditions for the pre/perilingual participants. Mean hearing handicap ratings improved post-implant for all participants indicating perceived benefit in everyday life with the addition of the cochlear implant. Conclusions Patients with asymmetric hearing loss who are not typical cochlear implant candidates can benefit from using a cochlear implant in the poorer ear with continued use of a hearing aid in the better ear. For this group of ten, the seven postlingually deafened participants showed greater benefits with the cochlear implant than the pre/perilingual participants; however, further study is needed to determine maximum benefit for those with early onset of hearing loss. PMID:22441359
Gifford, René H; Revit, Lawrence J
2010-01-01
Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise. Most speech perception measures in the clinical setting, however, do not provide a close approximation to real-world listening environments. To assess speech perception for adult cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE) array in order to determine whether commercially available preprocessing strategies and/or external accessories yield improved sentence recognition in noise. Single-subject, repeated-measures design with two groups of participants: Advanced Bionics and Cochlear Corporation recipients. Thirty-four subjects, ranging in age from 18 to 90 yr (mean 54.5 yr), participated in this prospective study. Fourteen subjects were Advanced Bionics recipients, and 20 subjects were Cochlear Corporation recipients. Speech reception thresholds (SRTs) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the subjects' preferred listening programs as well as with the addition of either Beam preprocessing (Cochlear Corporation) or the T-Mic accessory option (Advanced Bionics). In Experiment 1, adaptive SRTs with the Hearing in Noise Test sentences were obtained for all 34 subjects. For Cochlear Corporation recipients, SRTs were obtained with their preferred everyday listening program as well as with the addition of Focus preprocessing. For Advanced Bionics recipients, SRTs were obtained with the integrated behind-the-ear (BTE) mic as well as with the T-Mic. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the preprocessing strategy or external accessory in reducing the SRT in noise. In addition, a standard t-test was run to evaluate effectiveness across manufacturer for improving the SRT in noise. In Experiment 2, 16 of the 20 Cochlear Corporation subjects were reassessed obtaining an SRT in noise using the manufacturer-suggested "Everyday," "Noise," and "Focus" preprocessing strategies. A repeated-measures ANOVA was employed to assess the effects of preprocessing. The primary findings were (i) both Noise and Focus preprocessing strategies (Cochlear Corporation) significantly improved the SRT in noise as compared to Everyday preprocessing, (ii) the T-Mic accessory option (Advanced Bionics) significantly improved the SRT as compared to the BTE mic, and (iii) Focus preprocessing and the T-Mic resulted in similar degrees of improvement that were not found to be significantly different from one another. Options available in current cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise with both Cochlear Corporation and Advanced Bionics systems. For Cochlear Corporation recipients, Focus preprocessing yields the best speech-recognition performance in a complex listening environment; however, it is recommended that Noise preprocessing be used as the new default for everyday listening environments to avoid the need for switching programs throughout the day. For Advanced Bionics recipients, the T-Mic offers significantly improved performance in noise and is recommended for everyday use in all listening environments. American Academy of Audiology.
Improving speech perception in noise for children with cochlear implants.
Gifford, René H; Olund, Amy P; Dejong, Melissa
2011-10-01
Current cochlear implant recipients are achieving increasingly higher levels of speech recognition; however, the presence of background noise continues to significantly degrade speech understanding for even the best performers. Newer generation Nucleus cochlear implant sound processors can be programmed with SmartSound strategies that have been shown to improve speech understanding in noise for adult cochlear implant recipients. The applicability of these strategies for use in children, however, is not fully understood nor widely accepted. To assess speech perception for pediatric cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether Nucleus sound processor SmartSound strategies yield improved sentence recognition in noise for children who learn language through the implant. Single subject, repeated measures design. Twenty-two experimental subjects with cochlear implants (mean age 11.1 yr) and 25 control subjects with normal hearing (mean age 9.6 yr) participated in this prospective study. Speech reception thresholds (SRT) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the experimental subjects' everyday program incorporating Adaptive Dynamic Range Optimization (ADRO) as well as with the addition of Autosensitivity control (ASC). Adaptive SRTs with the Hearing In Noise Test (HINT) sentences were obtained for all 22 experimental subjects, and performance-in percent correct-was assessed in a fixed +6 dB SNR (signal-to-noise ratio) for a six-subject subset. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the SmartSound setting on the SRT in noise. The primary findings mirrored those reported previously with adult cochlear implant recipients in that the addition of ASC to ADRO significantly improved speech recognition in noise for pediatric cochlear implant recipients. The mean degree of improvement in the SRT with the addition of ASC to ADRO was 3.5 dB for a mean SRT of 10.9 dB SNR. Thus, despite the fact that these children have acquired auditory/oral speech and language through the use of their cochlear implant(s) equipped with ADRO, the addition of ASC significantly improved their ability to recognize speech in high levels of diffuse background noise. The mean SRT for the control subjects with normal hearing was 0.0 dB SNR. Given that the mean SRT for the experimental group was 10.9 dB SNR, despite the improvements in performance observed with the addition of ASC, cochlear implants still do not completely overcome the speech perception deficit encountered in noisy environments accompanying the diagnosis of severe-to-profound hearing loss. SmartSound strategies currently available in latest generation Nucleus cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise for pediatric cochlear implant recipients. Despite the reluctance of pediatric audiologists to utilize SmartSound settings for regular use, the results of the current study support the addition of ASC to ADRO for everyday listening environments to improve speech perception in a child's typical everyday program. American Academy of Audiology.
Alternating Current Delivered into the Scala Media Alters Sound Pressure at the Eardrum
NASA Astrophysics Data System (ADS)
Hubbard, Allyn E.; Mountain, David C.
1983-11-01
Alternating current delivered into the scala media of the gerbil cochlea modulates the amplitude of a test tone measured near the eardrum. Variations in the electromechanical effect with acoustic stimulus parameters and observed physiological vulnerability suggest that cochlear hair cells are the biophysical origin of the process. Cochlear hair cells have traditionally been thought of as passive receptor cells, but they may play an active role in cochlear micromechanics.
Investigation of Notch Signaling during Spontaneous Regeneration of Cochlear Hair Cells
2016-10-01
AWARD NUMBER: W81XWH-15-1-0475 TITLE: Investigation of Notch Signaling during Spontaneous Regeneration of Cochlear Hair Cells PRINCIPAL...Sep 2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Investigation of Notch Signaling during Spontaneous Regeneration of Cochlear Hair Cells 5b...inherent to military settings. These noise exposures damage and kill sensory hair cells (HCs) found in the cochlea of the inner ear, resulting in permanent
2015-06-01
K.C. and Hu, B.H. 2006. The role of oxidative stress in noise-induced hearing loss. Ear Hear 27(1): 1-19. Hillerdal, M. 1987. Cochlear blood flow ...Larsen, H.C., Angelborg, C. and Slepecky, N. 1984. Determination of the regional cochlear blood flow in the rat cochlea using non-radioactive...24-Hour JP-8 Exposure using a Cochlear Cell Model and Cellular Pathway Modulation
Stanford Center for Military Photomedicine
2014-09-08
cochlear implants after blast injury. A.2. WOUND HEALING. We have used several in vivo and in vitro models of wound healing to study the basic cell and...clinical information we will obtain has the potential to fundamentally alter the diagnosis and treatment of human cochlear pathology. Our microscope...of live guinea pigs, and have shown that FME can resolve cochlear structures in live subjects in a manner far superior to that of any other existing
Evaluation of Jet Fuel and Noise-Induced Hearing Loss in Rats (Rattus norvegicus)
2014-05-13
product otoacoustic emissions (DPOAE) and compound action potential (CAP) testing of the cochlear nerve. Inner ear hair cell loss was also not affected...conclusion by revealing that exposure to JP-8 combined with noise may result in the loss of pre-neural cochlear sensitivity as shown by suppression of...distortion product otoacoustic emissions (DPOAE) and depletion of cochlear sensory cells as evidenced by cytocochleograms that plot the percentage of
2016-07-05
occlusion of the anterior inferior cerebellar artery (AICA) and downstream vessels leading to cochlear hypoxia (18-24). Relevant to this work, PAN has...macaques showed moderate lymphoplasmacytic to chronic-active perivascular inflammation of the inner ear adjacent to the cochlear nerve The...inflammation occasionally surrounded smaller branches of the cochlear nerve, resembling pathological changes seen in humans diagnosed with PAN (Fig. 3B-E) (21
Cochlear Implantation in the Very Young Child: Issues Unique to the Under-1 Population
Cosetti, Maura; Roland, J. Thomas
2010-01-01
Since the advent of cochlear implantation, candidacy criteria have slowly broadened to include increasingly younger patients. Spurred by evidence demonstrating both perioperative safety and significantly increased speech and language benefit with early auditory intervention, children younger than 12 months of age are now being successfully implanted at many centers. This review highlights the unique challenges involved in cochlear implantation in the very young child, specifically diagnosis and certainty of testing, anesthetic risk, surgical technique, intraoperative testing and postoperative programming, long-term safety, development of receptive and expressive language, and outcomes of speech perception. Overall, the current body of literature indicates that cochlear implantation prior to 1 year of age is both safe and efficacious. PMID:20483813
Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P
2018-03-01
Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p < 0.001). There was strong agreement between standard manual testing and remote automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR120 177.0 μV, SD 11.57; p value < 0.001). These preliminary data demonstrate that intraoperative cochlear implant device testing using a remote automated system is feasible. This system may be useful for cochlear implant programs with limited audiology support or for programs looking to streamline intraoperative device testing protocols. Future studies with larger patient enrollment are required to validate these promising, but preliminary, findings.
... tinnitus in a significant number of study volunteers. Cochlear implants are sometimes used in people who have tinnitus along with severe hearing loss. A cochlear implant bypasses the damaged portion of the inner ...
Developmental Effects of Family Environment on Outcomes in Pediatric Cochlear Implant Recipients
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.
2012-01-01
Objective To examine and compare the family environment of preschool- and school-age children with cochlear implants and assess its influence on children’s executive function and spoken language skills. Study Design Retrospective between-subjects design. Setting Outpatient research laboratory. Patients Prelingually deaf children with cochlear implants and no additional disabilities, and their families. Intervention(s) Cochlear implantation and speech-language therapy. Main Outcome Measures Parents completed the Family Environment Scale and the Behavior Rating Inventory of Executive Function (or the preschool version). Children were tested using the Peabody Picture Vocabulary Test-4 and either the Preschool Language Scales-4 or the Clinical Evaluation of Language Fundamentals–4. Results The family environments of children with cochlear implants differed from normative data obtained from hearing children, but average scores were within one standard deviation of norms on all subscales. Families of school-age children reported higher levels of control than those of preschool-age children. Preschool-age children had fewer problems with emotional control when families reported higher levels of support and lower levels of conflict. School-age children had fewer problems with inhibition but more problems with shifting of attention when families reported lower levels of conflict. School-age children’s receptive vocabularies were enhanced by families with lower levels of control and higher levels of organization. Conclusions Family environment and its relation to language skills and executive function development differed across the age groups in this sample of children with cochlear implants. Because family dynamics is one developmental/environmental factor that can be altered with therapy and education, the present results have important clinical implications for family-based interventions for deaf children with cochlear implants. PMID:23151776
Development and evaluation of the Nurotron 26-electrode cochlear implant system.
Zeng, Fan-Gang; Rebscher, Stephen J; Fu, Qian-Jie; Chen, Hongbin; Sun, Xiaoan; Yin, Li; Ping, Lichuan; Feng, Haihong; Yang, Shiming; Gong, Shusheng; Yang, Beibei; Kang, Hou-Yong; Gao, Na; Chi, Fanglu
2015-04-01
Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled
Schvartz-Leyzac, Kara C; Pfingst, Bryan E
2016-11-01
Electrically evoked compound action potential (ECAP) measures of peak amplitude, and amplitude-growth function (AGF) slope have been shown to reflect characteristics of cochlear health (primarily spiral ganglion density) in anesthetized cochlear-implanted guinea pigs. Likewise, the effect of increasing the interphase gap (IPG) in each of these measures also reflects SGN density in the implanted guinea pig. Based on these findings, we hypothesize that suprathreshold ECAP measures, and also how they change as the IPG is increased, have the potential to be clinically applicable in human subjects. However, further work is first needed in order to determine the characteristics of these measures in humans who use cochlear implants. The current study examined across-site patterns of suprathreshold ECAP measures in 10 bilaterally-implanted, adult cochlear implant users. Results showed that both peak amplitude and slope of the AGF varied significantly from electrode to electrode in ear-specific patterns across the subjects' electrode arrays. As expected, increasing the IPG on average increased the peak amplitude and slope. Across ears, there was a significant, negative correlation between the slope of the ECAP AGF and the duration of hearing loss. Across-site patterns of ECAP peak amplitude and AGF slopes were also compared with common ground impedance values and significant correlations were observed in some cases, depending on the subject and condition. The results of this study, coupled with previous studies in animals, suggest that it is feasible to measure the change in suprathreshold ECAP measures as the IPG increases on most electrodes. Further work is needed to investigate the relationship between these measures and cochlear implant outcomes, and determine how these measures might be used when programming a cochlear-implant processor. Published by Elsevier B.V.
Hashemi, Sayed Basir; Rajaeefard, Abdolreza; Norouzpour, Hasan; Tabatabaee, Hamid Reza; Monshizadeh, Leila
2013-03-01
Hearing loss is the most common sensorineural deficiency in human beings. Cochlear implantation is introduced worldwide to treat the severe to profound sensorineural hearing loss, and can result in both speech comprehension and production. The present study aims to determine the effect of cochlear implantation on the improvement of the auditory performance in 2-7 years old children. The present follow-up study is a kind of cohort study which was conducted on 98 children between 2-7 years old who had referred to Fars Cochlear Implantation Center. The patients' information was gathered from their profiles both before and after the operation. The auditory performance score was obtained in 3 stages; 6 months, 1 year, and 2 years after the cochlear implantation through the Cap test. The data was analyzed using the nonparametric Friedman test as well as Mann-Withney, Kruskal-Wallis, and Spearman's Ranks Correlation coefficients. The mean and the median of the auditory performance score of the children who had undergone the cochlear implantation revealed a significant improvement from 6 months to 1 year, and 2 years after the implantation. It showed a significant statistical association between implantation age, type of hearing loss, regular reference, and the length of being present in the rehabilitation program with the auditory performance. It showed no significant association between sex, mother's level of education, being monolingual or bilingual, and family size with the auditory performance. This study revealed that the type of hearing loss, Presence in the rehabilitation program, and the age of cochlear implantation can be major prognostic factors of the response to the treatment, then the country's health policy makers and health planners must executively take into account the infants' hearing screening program during the first 6 month of age.
Auditory Cortex Basal Activity Modulates Cochlear Responses in Chinchillas
León, Alex; Elgueda, Diego; Silva, María A.; Hamamé, Carlos M.; Delano, Paul H.
2012-01-01
Background The auditory efferent system has unique neuroanatomical pathways that connect the cerebral cortex with sensory receptor cells. Pyramidal neurons located in layers V and VI of the primary auditory cortex constitute descending projections to the thalamus, inferior colliculus, and even directly to the superior olivary complex and to the cochlear nucleus. Efferent pathways are connected to the cochlear receptor by the olivocochlear system, which innervates outer hair cells and auditory nerve fibers. The functional role of the cortico-olivocochlear efferent system remains debated. We hypothesized that auditory cortex basal activity modulates cochlear and auditory-nerve afferent responses through the efferent system. Methodology/Principal Findings Cochlear microphonics (CM), auditory-nerve compound action potentials (CAP) and auditory cortex evoked potentials (ACEP) were recorded in twenty anesthetized chinchillas, before, during and after auditory cortex deactivation by two methods: lidocaine microinjections or cortical cooling with cryoloops. Auditory cortex deactivation induced a transient reduction in ACEP amplitudes in fifteen animals (deactivation experiments) and a permanent reduction in five chinchillas (lesion experiments). We found significant changes in the amplitude of CM in both types of experiments, being the most common effect a CM decrease found in fifteen animals. Concomitantly to CM amplitude changes, we found CAP increases in seven chinchillas and CAP reductions in thirteen animals. Although ACEP amplitudes were completely recovered after ninety minutes in deactivation experiments, only partial recovery was observed in the magnitudes of cochlear responses. Conclusions/Significance These results show that blocking ongoing auditory cortex activity modulates CM and CAP responses, demonstrating that cortico-olivocochlear circuits regulate auditory nerve and cochlear responses through a basal efferent tone. The diversity of the obtained effects suggests that there are at least two functional pathways from the auditory cortex to the cochlea. PMID:22558383
Noise alters hair-bundle mechanics at the cochlear apex
NASA Astrophysics Data System (ADS)
Strimbu, C. Elliott; Fridberger, Anders
2015-12-01
Exposure to loud sounds can lead to both permanent and short term changes in auditory sensitivity. Permanent hearing loss is often associated with gross changes in cochlear morphology including the loss of hair cells and auditory nerve fibers while the mechanisms of short term threshold shifts are much less well understood and may vary at different locations across the cochlea. Previous reports suggest that exposure to loud sounds leads to a decrease in the cochlear microphonic potential and in the stiffness of the organ of Corti. Because the cochlear microphonic reflects changes in the membrane potential of the hair cells, this suggests that hair-bundle motion should be reversibly altered following exposure to loud sounds. Using an in vitro preparation of the guinea pig temporal bone we investigate changes in the micro-mechanical response near the cochlear apex following a brief (up to 10 - 20 minutes) exposure to loud (˜ 120 dB) tones near the best frequency at this location. We use time-resolved confocal imaging to record the motion of outer hair cell bundles before and after acoustic overstimulation. We have also recorded larger-scale structural views of the organ of Corti before and after exposure to the loud sound. Conventional electrophysiological techniques are used measure the cochlear microphonic potential. As has been previously reported, following acoustic overexposure the cochlear microphonic declines in value and typically recovers on the order of 30 - 60 minutes. Hair-bundle trajectories are affected following the loud sound and typically recover on a somewhat faster time scale than the microphonic potential, although the results vary considerably across preparations. Preliminary results also suggest reversible changes in the hair cell's resting potential following the loud sound.
Chang, Andrew; Eastwood, Hayden; Sly, David; James, David; Richardson, Rachael; O'Leary, Stephen
2009-09-01
To protect hearing in an experimental model of cochlear implantation by the application of dexamethasone to the round window prior to surgery. The present study examined the dosage and timing relationships required to optimise the hearing protection. Dexamethasone or saline (control) was absorbed into a pledget of the carboxymethylcellulose and hyaluronic acid and applied to the round window of the guinea pig prior to cochlear implantation. The treatment groups were 2% w/v dexamethasone for 30, 60 and 120min; 20% dexamethasone applied for 30min. Auditory sensitivity was determined pre-operatively, and at 1 week after surgery, with pure-tone auditory brainstem response audiometry (2-32kHz). Cochlear implantation was performed via a cochleostomy drilled into the basal turn of the cochlea, into which a miniature cochlear implant dummy electrode was inserted using soft-surgery techniques. ABR thresholds were elevated after cochlear implantation, maximally at 32kHz and to a lesser extent at lower frequencies. Thresholds were less elevated after dexamethasone treatment, and the hearing protection improved when 2% dexamethasone was applied to the round window for longer periods of time prior to implantation. The time that dexamethasone need be applied to achieve hearing protection could be reduced by increasing the concentration of steroid, with a 20% application for 30min achieving similar levels of protection to a 60min application of 2% dexamethasone. Hearing protection is improved by increasing the time that dexamethasone is applied to the round window prior to cochlear implantation, and the waiting time can be reduced by increasing the steroid concentration. These results suggest that the diffusion dexamethasone through the cochlea is the prime determinant of the extent of hearing protection.
Távora-Vieira, Dayse; Marino, Roberta; Acharya, Aanand; Rajan, Gunesh P
2015-03-01
This study aimed to determine the impact of cochlear implantation on speech understanding in noise, subjective perception of hearing, and tinnitus perception of adult patients with unilateral severe to profound hearing loss and to investigate whether duration of deafness and age at implantation would influence the outcomes. In addition, this article describes the auditory training protocol used for unilaterally deaf patients. This is a prospective study of subjects undergoing cochlear implantation for unilateral deafness with or without associated tinnitus. Speech perception in noise was tested using the Bamford-Kowal-Bench speech-in-noise test presented at 65 dB SPL. The Speech, Spatial, and Qualities of Hearing Scale and the Abbreviated Profile of Hearing Aid Benefit were used to evaluate the subjective perception of hearing with a cochlear implant and quality of life. Tinnitus disturbance was measured using the Tinnitus Reaction Questionnaire. Data were collected before cochlear implantation and 3, 6, 12, and 24 months after implantation. Twenty-eight postlingual unilaterally deaf adults with or without tinnitus were implanted. There was a significant improvement in speech perception in noise across time in all spatial configurations. There was an overall significant improvement on the subjective perception of hearing and quality of life. Tinnitus disturbance reduced significantly across time. Age at implantation and duration of deafness did not influence the outcomes significantly. Cochlear implantation provided significant improvement in speech understanding in challenging situations, subjective perception of hearing performance, and quality of life. Cochlear implantation also resulted in reduced tinnitus disturbance. Age at implantation and duration of deafness did not seem to influence the outcomes.
Psarros, Colleen; Love, Sarah
2016-01-01
Newborn hearing screening has led to the early diagnosis of hearing loss in neonates and early device fitting is common, based primarily on electrophysiologic and radiologic information, with some supplementary behavioral measures. Such early fitting of hearing devices, in particular cochlear implants (CIs), has been beneficial to the majority of children implanted under the age of 12 months who meet the cochlear implant candidacy criteria. Comorbidities are common in children with hearing loss, although they may not be evident in neonates and may not emerge until later in infants. Evidence suggests that the child's outcomes are strongly influenced by a range of environmental factors including emotional and social support from the immediate and extended family. Consequently, such factors are important in service planning and service delivery for babies and children receiving CIs. The World Health Organization's International Classification of Functioning, Health and Disability (ICF) can provide a framework to facilitate the holistic management of pediatric cochlear implant recipients. The ICF also can be used to map the progress of recipients over time to highlight emerging issues that require intervention. This article will discuss our preliminary use of the ICF to establish clinical practice; develop advocacy skills among clients and their families; identify eligibility for services such as support in educational settings; enable access to modes of service delivery such as telepractice; provide a conceptual framework for policy and program development for pediatric cochlear implant recipients (i.e., in both disability and health services); and, most importantly, establish a clear pathway for the longitudinal management of the cochlear implant in a child's future. It is anticipated that this model will be applied to other populations receiving cochlear implants through our program. PMID:27489404
Sharma, Anu; Campbell, Julia; Cardon, Garrett
2015-02-01
Cortical development is dependent on extrinsic stimulation. As such, sensory deprivation, as in congenital deafness, can dramatically alter functional connectivity and growth in the auditory system. Cochlear implants ameliorate deprivation-induced delays in maturation by directly stimulating the central nervous system, and thereby restoring auditory input. The scenario in which hearing is lost due to deafness and then reestablished via a cochlear implant provides a window into the development of the central auditory system. Converging evidence from electrophysiologic and brain imaging studies of deaf animals and children fitted with cochlear implants has allowed us to elucidate the details of the time course for auditory cortical maturation under conditions of deprivation. Here, we review how the P1 cortical auditory evoked potential (CAEP) provides useful insight into sensitive period cut-offs for development of the primary auditory cortex in deaf children fitted with cochlear implants. Additionally, we present new data on similar sensitive period dynamics in higher-order auditory cortices, as measured by the N1 CAEP in cochlear implant recipients. Furthermore, cortical re-organization, secondary to sensory deprivation, may take the form of compensatory cross-modal plasticity. We provide new case-study evidence that cross-modal re-organization, in which intact sensory modalities (i.e., vision and somatosensation) recruit cortical regions associated with deficient sensory modalities (i.e., auditory) in cochlear implanted children may influence their behavioral outcomes with the implant. Improvements in our understanding of developmental neuroplasticity in the auditory system should lead to harnessing central auditory plasticity for superior clinical technique. Copyright © 2014 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Nicholas, Johanna Grant; Geers, Ann E.
2007-01-01
Purpose: The authors examined the benefits of younger cochlear implantation, longer cochlear implant use, and greater pre-implant aided hearing to spoken language at 3.5 and 4.5 years of age. Method: Language samples were obtained at ages 3.5 and 4.5 years from 76 children who received an implant by their 3rd birthday. Hierarchical linear modeling…
Biomechanical Modeling and Measurement of Blast Injury and Hearing Protection Mechanisms
2015-10-01
12 software into Workbench V. 15 in CFX/ANSYS; 2) building the geometry of the ear model with ossicular chain and cochlear load in CFX; 3...the ear canal to middle ear. The model consists of the ear canal, TM, middle ear ossicles and suspensory ligaments, middle ear cavity, and cochlear ...the TM, ossicles, and ligaments/muscle tendons with the cochlear load applied on the stapes footplate. 17 Fig. 21. Time-history plots of
Scarbel, Lucie; Beautemps, Denis; Schwartz, Jean-Luc; Sato, Marc
2017-07-01
Speech communication can be viewed as an interactive process involving a functional coupling between sensory and motor systems. One striking example comes from phonetic convergence, when speakers automatically tend to mimic their interlocutor's speech during communicative interaction. The goal of this study was to investigate sensory-motor linkage in speech production in postlingually deaf cochlear implanted participants and normal hearing elderly adults through phonetic convergence and imitation. To this aim, two vowel production tasks, with or without instruction to imitate an acoustic vowel, were proposed to three groups of young adults with normal hearing, elderly adults with normal hearing and post-lingually deaf cochlear-implanted patients. Measure of the deviation of each participant's f 0 from their own mean f 0 was measured to evaluate the ability to converge to each acoustic target. showed that cochlear-implanted participants have the ability to converge to an acoustic target, both intentionally and unintentionally, albeit with a lower degree than young and elderly participants with normal hearing. By providing evidence for phonetic convergence and speech imitation, these results suggest that, as in young adults, perceptuo-motor relationships are efficient in elderly adults with normal hearing and that cochlear-implanted adults recovered significant perceptuo-motor abilities following cochlear implantation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Leybaert, Jacqueline; LaSasso, Carol J.
2010-01-01
Nearly 300 million people worldwide have moderate to profound hearing loss. Hearing impairment, if not adequately managed, has strong socioeconomic and affective impact on individuals. Cochlear implants have become the most effective vehicle for helping profoundly deaf children and adults to understand spoken language, to be sensitive to environmental sounds, and, to some extent, to listen to music. The auditory information delivered by the cochlear implant remains non-optimal for speech perception because it delivers a spectrally degraded signal and lacks some of the fine temporal acoustic structure. In this article, we discuss research revealing the multimodal nature of speech perception in normally-hearing individuals, with important inter-subject variability in the weighting of auditory or visual information. We also discuss how audio-visual training, via Cued Speech, can improve speech perception in cochlear implantees, particularly in noisy contexts. Cued Speech is a system that makes use of visual information from speechreading combined with hand shapes positioned in different places around the face in order to deliver completely unambiguous information about the syllables and the phonemes of spoken language. We support our view that exposure to Cued Speech before or after the implantation could be important in the aural rehabilitation process of cochlear implantees. We describe five lines of research that are converging to support the view that Cued Speech can enhance speech perception in individuals with cochlear implants. PMID:20724357
Chang, Pamara F
2017-08-01
To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.
Ou, Henry; Cleary, Patricia; Sie, Kathleen
2010-10-01
To demonstrate the use of a state-maintained database (CHILD Profile) to monitor immunization status of pediatric cochlear implant recipients, and to assess compliance with current vaccination recommendations for cochlear implant users managed at Seattle Children's Hospital. Cross-sectional study. Tertiary academic pediatric hospital. Subjects were 260 patients with cochlear implants managed at Seattle Children's Hospital between July 1, 1995, and May 1, 2008. Patients were stratified by age groups (0-2 years, 2-5 years, 5-10 years, > 10 years). Using a statewide children's immunization registry (CHILD Profile), subjects were assessed with regard to their immunization status for Haemophilus influenzae type B vaccination (HiB), 7-valent pneumococcal conjugate vaccination (PCV-7), and 23-valent pneumococcal polysaccharide vaccine (PPV-23). Two hundred twenty-five of 260 subjects (87%) were registered in CHILD Profile; 126 of 225 (56%) were up to date with CDC recommendations for patients with cochlear implants. PPV-23 was the vaccination most likely to be incomplete. Age was predictive of immunization status only with HiB vaccination. A statewide immunization registry can be used to monitor the immunization status of cochlear implant recipients. Subjects were significantly more likely to be incomplete for PPV-23 than for either PCV-7 or HiB vaccinations. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.
Noise-induced cochlear synaptopathy: Past findings and future studies.
Kobel, Megan; Le Prell, Colleen G; Liu, Jennifer; Hawks, John W; Bao, Jianxin
2017-06-01
For decades, we have presumed the death of hair cells and spiral ganglion neurons are the main cause of hearing loss and difficulties understanding speech in noise, but new findings suggest synapse loss may be the key contributor. Specifically, recent preclinical studies suggest that the synapses between inner hair cells and spiral ganglion neurons with low spontaneous rates and high thresholds are the most vulnerable subcellular structures, with respect to insults during aging and noise exposure. This cochlear synaptopathy can be "hidden" because this synaptic loss can occur without permanent hearing threshold shifts. This new discovery of synaptic loss opens doors to new research directions. Here, we review a number of recent studies and make suggestions in two critical future research directions. First, based on solid evidence of cochlear synaptopathy in animal models, it is time to apply molecular approaches to identify the underlying molecular mechanisms; improved understanding is necessary for developing rational, effective therapies against this cochlear synaptopathy. Second, in human studies, the data supporting cochlear synaptopathy are indirect although rapid progress has been made. To fully identify changes in function that are directly related this hidden synaptic damage, we argue that a battery of tests including both electrophysiological and behavior tests should be combined for diagnosis of "hidden hearing loss" in clinical studies. This new approach may provide a direct link between cochlear synaptopathy and perceptual difficulties. Copyright © 2016 Elsevier B.V. All rights reserved.
Cysneiros, Helena Renata Silva; Leal, Mariana de Carvalho; Lucena, Jonia Alves; Muniz, Lilian Ferreira
To conduct a systematic review of the scientific literature studying the relationship between vocal production and auditory perception in cochlear implant users. This is an integrative systematic review. The plattforms/databases Bireme, SciELO, Cochrane, Scopus and Web of Science were consulted and the descriptors used were voice, cochlear implant and auditory perception. Original papers published in English, French, Spanish or Portuguese involving the study of vocal production and auditory perception in cochlear implant users were selected and there was no restriction about year of publication of the articles. The studies selected were analyzed according to the author, location, year and publication of the article, as well as for their sample size, type of vocal production and auditory perception assessment and for its major findings and recommendation grade/level of scientific evidence. The results suggest the existence of positive relationship between vocal production and auditory perception in cochlear implant users, and indicate that the deployment time has a positive influence in this relationship. None of the selected studies were rated at level 1 of scientific evidence or grade A of recommendation, which is related to the methodological approach that can go with this subject matter. There is great lack of publications relating auditory perception and speech production in cochlear implant users. This gap is even greater when it comes to the adult population.
Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez
2016-01-01
The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Birman, Catherine S; Elliott, Elizabeth J; Gibson, William P R
2012-10-01
To determine the prevalence of additional disabilities in a pediatric cochlear population, to identify medical and radiologic conditions associated with additional disabilities, and to identify the effect of additional disabilities on speech perception and language at 12 months postoperatively. Retrospective case review. Tertiary referral center and cochlear implant program. Records were reviewed for children 0 to 16 years old inclusive, who had cochlear implant-related operations over a 12-month period. Diagnostic and rehabilitative. Additional disabilities prevalence; medical history and radiologic abnormalities; and the effect on Categories of Auditory Performance (CAP) score at 12 months postoperatively. Eighty-eight children having 96 operations were identified. The overall prevalence of additional disabilities (including developmental delay, cerebral palsy, visual impairment, autism and attention deficit disorder) was 33%. The main conditions associated with additional disabilities were syndromes and chromosomal abnormalities (87%), jaundice (86%), prematurity (62%), cytomegalovirus (60%), and inner ear abnormalities including cochlea nerve hypoplasia or aplasia (75%) and semicircular canal anomalies (56%). At 12 months postoperatively, almost all (96%) of the children without additional disabilities had a CAP score of 5 or greater (speech), compared with 52% of children with additional disabilities. Children with developmental delay had a median CAP score of 4, at 12 months compared with 6 for those without developmental delay. Additional disabilities are prevalent in approximately a third of pediatric cochlear implant patients. Additional disabilities significantly affect the outcomes of cochlear implants.
Yang, Shuzhi; Cai, Qunfeng; Bard, Jonathan; Jamison, Jennifer; Wang, Jianmin; Yang, Weiping; Hu, Bo Hua
2015-12-01
Individual variation in the susceptibility of the auditory system to acoustic overstimulation has been well-documented at both the functional and structural levels. However, the molecular mechanism responsible for this variation is unclear. The current investigation was designed to examine the variation patterns of cochlear gene expression using RNA-seq data and to identify the genes with expression variation that increased following acoustic trauma. This study revealed that the constitutive expressions of cochlear genes displayed diverse levels of gene-specific variation. These variation patterns were altered by acoustic trauma; approximately one-third of the examined genes displayed marked increases in their expression variation. Bioinformatics analyses revealed that the genes that exhibited increased variation were functionally related to cell death, biomolecule metabolism, and membrane function. In contrast, the stable genes were primarily related to basic cellular processes, including protein and macromolecular syntheses and transport. There was no functional overlap between the stable and variable genes. Importantly, we demonstrated that glutamate metabolism is related to the variation in the functional response of the cochlea to acoustic overstimulation. Taken together, the results indicate that our analyses of the individual variations in transcriptome changes of cochlear genes provide important information for the identification of genes that potentially contribute to the generation of individual variation in cochlear responses to acoustic overstimulation. Copyright © 2015 Elsevier B.V. All rights reserved.
Hashemi, Seyed Basir; Monshizadeh, Leila
2012-06-01
Before the introduction of cochlear implant (CI) in 1980, hearing aids were the only means by which profoundly deaf children had access to auditory stimuli. Nowadays, CI is firmly established as effective option in speech and language rehabilitation of deaf children, but much of the literature regarding outcomes for children after CI are focused on development of speech and less is known about language acquisition. So, the main aim of this study is the evaluation of verbal intelligence quotient (IQ) of cochlear implanted children in comparison with normal children. 30 cochlear implanted and 30 normal hearing children with similar socio-economic level at the same age were compared by a revised version (in Persian) of WISC test (Wechsler, 1991). Then the data were analyzed through SPSS software 16. In spite of the fact that cochlear implanted children did well in different parameters of WISC test, the average scores of this group was less than normal hearing children. But in similarities (one of the parameters of WISC test) 2 group's performance was approximately the same. CI plays an important role in development of verbal IQ and language acquisition of deaf children. Different researches indicate that most of the cochlear implanted children show less language delay during the time. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and post-implant language development and executive function. Method Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (FES) and an inventory of executive function (BRIEF/BRIEF-P). Children’s receptive vocabulary (PPVT-4) and global language skills (PLS-4/CELF-4) were also evaluated. Results The family environments of children with cochlear implants differed from those of normal-hearing children, but not in clinically significant ways. Language development and executive function were found to be atypical, but not uncharacteristic of this clinical population. Families with higher levels of self-reported control had children with smaller vocabularies. Families reporting a higher emphasis on achievement had children with fewer executive function and working memory problems. Finally, families reporting a higher emphasis on organization had children with fewer problems related to inhibition. Conclusions Some of the variability in cochlear implantation outcomes that have protracted periods of development is related to family environment. Because family environment can be modified and enhanced by therapy or education, these preliminary findings hold promise for future work in helping families to create robust language-learning environments that can maximize their child’s potential with a cochlear implant. PMID:22232387
Ihler, Friedrich; Sharaf, Kariem; Bertlich, Mattis; Strieth, Sebastian; Reichel, Christoph A; Berghaus, Alexander; Canis, Martin
2013-07-01
Tumor necrosis factor alpha (TNF-alpha) is a mediator of inflammation and microcirculation in the cochlea. This study aimed to quantify the effect of a local increase of TNF-alpha and study the effect of its interaction with etanercept on cochlear microcirculation. Cochlear lateral wall vessels were exposed surgically and assessed by intravital microscopy in guinea pigs in vivo. First, 24 animals were randomly distributed into 4 groups of 6 each. Exposed vessels were superfused repeatedly either with 1 of 3 different concentrations of TNF-alpha (5.0, 0.5, and 0.05 ng/mL) or with placebo (0.9% saline solution). Second, 12 animals were randomly distributed into 2 groups of 6 each. Vessels were pretreated with etanercept (1.0 microg/ mL) or placebo (0.9% saline solution), and then treated by repeated superfusion with TNF-alpha (5.0 ng/mL). TNF-alpha was shown to be effective in decreasing cochlear blood flow at a dose of 5.0 ng/mL (p < 0.01, analysis of variance on ranks). Lower concentrations or placebo treatment did not lead to significant changes. After pretreatment with etanercept, TNF-alpha at a dose of 5.0 ng/mL no longer led to a change in cochlear blood flow. The decreasing effect that TNF-alpha has on cochlear blood flow is dose-dependent. Etanercept abrogates this effect.
Chung, King; Nelson, Lance; Teske, Melissa
2012-09-01
The purpose of this study was to investigate whether a multichannel adaptive directional microphone and a modulation-based noise reduction algorithm could enhance cochlear implant performance in reverberant noise fields. A hearing aid was modified to output electrical signals (ePreprocessor) and a cochlear implant speech processor was modified to receive electrical signals (eProcessor). The ePreprocessor was programmed to flat frequency response and linear amplification. Cochlear implant listeners wore the ePreprocessor-eProcessor system in three reverberant noise fields: 1) one noise source with variable locations; 2) three noise sources with variable locations; and 3) eight evenly spaced noise sources from 0° to 360°. Listeners' speech recognition scores were tested when the ePreprocessor was programmed to omnidirectional microphone (OMNI), omnidirectional microphone plus noise reduction algorithm (OMNI + NR), and adaptive directional microphone plus noise reduction algorithm (ADM + NR). They were also tested with their own cochlear implant speech processor (CI_OMNI) in the three noise fields. Additionally, listeners rated overall sound quality preferences on recordings made in the noise fields. Results indicated that ADM+NR produced the highest speech recognition scores and the most preferable rating in all noise fields. Factors requiring attention in the hearing aid-cochlear implant integration process are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.
Yoon, Yong-Jin; Steele, Charles R; Puria, Sunil
2011-01-05
The high sensitivity and wide bandwidth of mammalian hearing are thought to derive from an active process involving the somatic and hair-bundle motility of the thousands of outer hair cells uniquely found in mammalian cochleae. To better understand this, a biophysical three-dimensional cochlear fluid model was developed for gerbil, chinchilla, cat, and human, featuring an active "push-pull" cochlear amplifier mechanism based on the cytoarchitecture of the organ of Corti and using the time-averaged Lagrangian method. Cochlear responses are simulated and compared with in vivo physiological measurements for the basilar membrane (BM) velocity, V(BM), frequency tuning of the BM vibration, and Q₁₀ values representing the sharpness of the cochlear tuning curves. The V(BM) simulation results for gerbil and chinchilla are consistent with in vivo cochlea measurements. Simulated mechanical tuning curves based on maintaining a constant V(BM) value agree with neural-tuning threshold measurements better than those based on a constant displacement value, which implies that the inner hair cells are more sensitive to V(BM) than to BM displacement. The Q₁₀ values of the V(BM) tuning curve agree well with those of cochlear neurons across species, and appear to be related in part to the width of the basilar membrane. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Outcomes and special considerations of cochlear implantation in waardenburg syndrome.
Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke
2011-08-01
The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.
Profound hearing loss associated with hydrocodone/acetaminophen abuse.
Friedman, R A; House, J W; Luxford, W M; Gherini, S; Mills, D
2000-03-01
To describe profound hearing loss associated with hydrocodone overuse and the successful rehabilitation of these patients with cochlear implantation. Retrospective review. A tertiary otologic referral center. Twelve patients with rapidly progressive hearing loss and a concurrent history of hydrocodone overuse. Comprehensive medical histories, physical findings, audiometric tests, and, in those patients undergoing cochlear implantation, postimplantation performance data were reviewed. Clinical characteristics of hydrocodone-related hearing loss and open set word and sentence performance in those patients undergoing cochlear implantation. Hydrocodone overuse was associated with rapidly progressive sensorineural hearing loss in 12 patients. In four patients the initial presentation was unilateral, and two of the patients experienced vestibular symptoms. None of the 12 patients experienced improved thresholds after high-dose prednisone. Seven of the eight patients undergoing cochlear implantation have demonstrated early success with their devices. Hydrocodone is frequently prescribed in combination with acetaminophen for the relief of pain and has a side effects profile similar to other medications in its class. Although not described previously, overuse or abuse can be associated with a rapidly progressive sensorineural hearing loss. These patients can be successfully rehabilitated with cochlear implantation.
Karim, M R; Atoji, Y
2016-02-01
Glutamate is a principal excitatory neurotransmitter in the auditory system. Our previous studies revealed localization of glutamate receptor mRNAs in the pigeon cochlear nuclei, suggesting the existence of glutamatergic input from the auditory nerve to the brainstem. This study demonstrated localization of mRNAs for vesicular glutamate transporter 2 (vGluT2) and ionotropic glutamate receptors (AMPA, kainate and NMDA) in the auditory ganglion (AG) and cochlear nuclei (magnocellular, angular and laminar nuclei). VGluT2 mRNA was intensely expressed in AG and intensely or moderately in the cochlear nuclei. The AG and cochlear nuclei showed intense-to-moderate mRNA signals for GluA2, GluA3, GluA4, GluK4 and GluN1. These results suggest that the pigeon AG neurons receives glutamatergic input from hair cells and in turn projects to the magnocellular and angular nuclei. Glutamate may play a pivotal role in the excitatory synapse transmission in the peripheral auditory pathway of birds. © 2015 Blackwell Verlag GmbH.
Challenges in Improving Cochlear Implant Performance and Accessibility.
Zeng, Fan-Gang
2017-08-01
Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.
Resistance of Gerbil Auditory Function to Reversible Decrease in Cochlear Blood Flow.
El Afia, Fahd; Giraudet, Fabrice; Gilain, Laurent; Mom, Thierry; Avan, Paul
2017-01-01
The objective was to design in gerbils a model of reversible decrease in cochlear blood flow (CBF) and analyze its influence on cochlear function. In Mongolian gerbils injected with ferromagnetic microbeads, a magnet placed near the porus acusticus allowed CBF to be manipulated. The cochlear microphonic potential (CM) from the basal cochlea was monitored by a round-window electrode. In 13 of the 20 successfully injected gerbils, stable CBF reduction was obtained for 11.5 min on average. The CM was affected only when CBF fell to less than 60% of its baseline, yet remained >40% of its initial level in about 2/3 of such cases. After CBF restoration, CM recovery was fast and usually complete. Reduced CM came with a 35- to 45-dB threshold elevation of neural responses determined by compound action potentials. This method allowing reversible changes of CBF confirms the robustness of cochlear function to decreased CBF. It can be used to study whether a hypovascularized cochlea is abnormally sensitive to stress. © 2017 S. Karger AG, Basel.
Blood flow to the promontory in cochlear otosclerosis.
Nakashima, T; Sone, M; Fujii, H; Teranishi, M; Yamamoto, H; Otake, H; Sugiura, M; Naganawa, S
2006-04-01
To investigate Schwartze sign with measurements of blood flow to the promontory in patients with cochlear otosclerosis. Prospective clinical study. Tertiary referral centre. Five patients with cochlear otosclerosis and five control subjects. Significant decalcification around the cochlea was observed by computed tomography (CT) in patients with cochlear otosclerosis. However, no recognizable lesion was observed at the oval window in two patients. One patient had mixed hearing loss and four patients had sensorineural hearing loss without an air-bone gap. The relationship between CT findings and the presence or absence of Schwartze sign was investigated. Blood flow to the promontory was measured through the tympanic membrane using laser speckle flowgraphy and laser Doppler flowmetry. The Schwartze sign correlated significantly with otosclerotic lesions invading the promontory. Patients with otosclerosis exhibited elevated and pulsating blood flow to the promontory with the Schwartze sign. Computed tomography demonstrated that cochlear otosclerosis can exist without the oval window lesion. Schwartze sign can be used as a sign of the otosclerotic invasion to the promontory. The reddening of the Schwartze sign is likely due to increased blood flow.
NASA Astrophysics Data System (ADS)
Abiy, Lidet; Telischi, Fred; Parel, Jean-Marie A.; Manns, Fabrice; Saettele, Ralph; Morawski, Krzysztof; Ozdamar, Ozcan; Borgos, John; Delgado, Rafael; Miskiel, Edward; Yavuz, Erdem
2003-06-01
The aim of this project is the development of a microsurgical laser Doppler (LD) probe that simultaneously monitors blood flow and Electrocochleography (ECochG) from the round window of the ear. The device will prevent neurosensory hearing loss during acoustic neuroma surgery by preventing damage to the internal auditory nerve and to the cochlear blood flow supply. A commercially available 0.5 mm diameter Laser-Doppler velocimetry probe (LaserFlo, Vasamedics) was modified to integrate an ECochG electrode. A tube for suction and irrigation was incorporated into a sheath of the probe shaft, to facilitate cleaning of the round window (RW) and allow drug delivery to the round window membrane. The prototype microprobe was calibrated on a single vessel model and tested in vivo in a rabbit model. Preliminary results indicate that the microprobe was able to measure changes in cochlear blood flow (CBF) and ECochG potentials from the round window of rabbits in vivo. The microprobe is suitable for monitoring cochlear blood flow and auditory cochlear potentials during human surgery.
NASA Astrophysics Data System (ADS)
Yoon, Y.; Kim, N.; Puria, S.; Steele, C. R.
2009-02-01
In this work, basilar membrane velocity (VBM), scala tympani intracochlear pressure (PST), and cochlear input impedances (Zc) for gerbil and chinchilla are implemented using a three-dimensional hydro-dynamic cochlear model using 1) time-averaged Lagrangian, 2) push-pull mechanism in active case, and 3) the complex anatomy of cochlear scalae by micro computed tomography (μCT) scanning and 3-D reconstructions of gerbil and chinchilla temporal bones. The objective of this work is to compare the calculations and the physiological measurements of gerbil and chinchilla cochlear such as VBM (Ren and Nuttall [1]), PST (Olson [2]), and ZC (Decraemer et al. [3], Songer and Rosowski [4], Ruggero et al. [5]) with present model. A WKB asymptotic method combined with Fourier series expansions is used to provide an efficient simulation. VBM and PST simulation results for the gerbil cochlea show good agreement both in the magnitude and the phase for the physiological measurements without larger phase excursion. ZC simulation from the gerbil and chinchilla model show reasonably good agreement with measurement.
Modeling and segmentation of intra-cochlear anatomy in conventional CT
NASA Astrophysics Data System (ADS)
Noble, Jack H.; Rutherford, Robert B.; Labadie, Robert F.; Majdani, Omid; Dawant, Benoit M.
2010-03-01
Cochlear implant surgery is a procedure performed to treat profound hearing loss. Since the cochlea is not visible in surgery, the physician uses anatomical landmarks to estimate the pose of the cochlea. Research has indicated that implanting the electrode in a particular cavity of the cochlea, the scala tympani, results in better hearing restoration. The success of the scala tympani implantation is largely dependent on the point of entry and angle of electrode insertion. Errors can occur due to the imprecise nature of landmark-based, manual navigation as well as inter-patient variations between scala tympani and the anatomical landmarks. In this work, we use point distribution models of the intra-cochlear anatomy to study the inter-patient variations between the cochlea and the typical anatomic landmarks, and we implement an active shape model technique to automatically localize intra-cochlear anatomy in conventional CT images, where intra-cochlear structures are not visible. This fully automatic segmentation could aid the surgeon to choose the point of entry and angle of approach to maximize the likelihood of scala tympani insertion, resulting in more substantial hearing restoration.
NASA Astrophysics Data System (ADS)
Ramamoorthy, Sripriya; Zhang, Yuan; Petrie, Tracy; Fridberger, Anders; Ren, Tianying; Wang, Ruikang; Jacques, Steven L.; Nuttall, Alfred L.
2016-02-01
Sound processing in the inner ear involves separation of the constituent frequencies along the length of the cochlea. Frequencies relevant to human speech (100 to 500 Hz) are processed in the apex region. Among mammals, the guinea pig cochlear apex processes similar frequencies and is thus relevant for the study of speech processing in the cochlea. However, the requirement for extensive surgery has challenged the optical accessibility of this area to investigate cochlear processing of signals without significant intrusion. A simple method is developed to provide optical access to the guinea pig cochlear apex in two directions with minimal surgery. Furthermore, all prior vibration measurements in the guinea pig apex involved opening an observation hole in the otic capsule, which has been questioned on the basis of the resulting changes to cochlear hydrodynamics. Here, this limitation is overcome by measuring the vibrations through the unopened otic capsule using phase-sensitive Fourier domain optical coherence tomography. The optically and surgically advanced method described here lays the foundation to perform minimally invasive investigation of speech-related signal processing in the cochlea.
Audiologic features of Norrie disease.
Halpin, Chris; Owen, Grace; Gutiérrez-Espeleta, Gustavo A; Sims, Katherine; Rehm, Heidi L
2005-07-01
Norrie disease is an X-linked recessive disorder in which patients are born blind and develop sensory hearing loss in adolescence. The hearing loss associated with Norrie disease has been shown in a genetically altered knockout mouse to involve dysfunction of the stria vascularis; most other structures are preserved until the later stages of the disease. The objective of this study was to characterize the audiologic phenotype of Norrie disease for comparison with the pathophysiologic mechanism. The design combined two series of clinical audiologic evaluations, with special attention to speech intelligibility. The audiologic results for 12 affected individuals and 10 carriers show that patients with Norrie disease retain high speech intelligibility scores even when the threshold loss is severe. The cochlear mechanism-- failure of the stria vascularis-- accounts for some of the higher values in the wide distribution of speech scores in cases with similar pure tone audiograms.
... newsroom@entnet.org . A cochlear implant is an electronic device that restores partial hearing to individuals with ... An internal component that consists of a small electronic device that is surgically implanted under the skin ...
Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.
Alsanosi, A A
2015-09-01
To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.
Gifford, René H.; Revit, Lawrence J.
2014-01-01
Background Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise. Most speech perception measures in the clinical setting, however, do not provide a close approximation to real-world listening environments. Purpose To assess speech perception for adult cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether commercially available preprocessing strategies and/or external accessories yield improved sentence recognition in noise. Research Design Single-subject, repeated-measures design with two groups of participants: Advanced Bionics and Cochlear Corporation recipients. Study Sample Thirty-four subjects, ranging in age from 18 to 90 yr (mean 54.5 yr), participated in this prospective study. Fourteen subjects were Advanced Bionics recipients, and 20 subjects were Cochlear Corporation recipients. Intervention Speech reception thresholds (SRTs) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the subjects’ preferred listening programs as well as with the addition of either Beam™ preprocessing (Cochlear Corporation) or the T-Mic® accessory option (Advanced Bionics). Data Collection and Analysis In Experiment 1, adaptive SRTs with the Hearing in Noise Test sentences were obtained for all 34 subjects. For Cochlear Corporation recipients, SRTs were obtained with their preferred everyday listening program as well as with the addition of Focus preprocessing. For Advanced Bionics recipients, SRTs were obtained with the integrated behind-the-ear (BTE) mic as well as with the T-Mic. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the preprocessing strategy or external accessory in reducing the SRT in noise. In addition, a standard t-test was run to evaluate effectiveness across manufacturer for improving the SRT in noise. In Experiment 2, 16 of the 20 Cochlear Corporation subjects were reassessed obtaining an SRT in noise using the manufacturer-suggested “Everyday,” “Noise,” and “Focus” preprocessing strategies. A repeated-measures ANOVA was employed to assess the effects of preprocessing. Results The primary findings were (i) both Noise and Focus preprocessing strategies (Cochlear Corporation) significantly improved the SRT in noise as compared to Everyday preprocessing, (ii) the T-Mic accessory option (Advanced Bionics) significantly improved the SRT as compared to the BTE mic, and (iii) Focus preprocessing and the T-Mic resulted in similar degrees of improvement that were not found to be significantly different from one another. Conclusion Options available in current cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise with both Cochlear Corporation and Advanced Bionics systems. For Cochlear Corporation recipients, Focus preprocessing yields the best speech-recognition performance in a complex listening environment; however, it is recommended that Noise preprocessing be used as the new default for everyday listening environments to avoid the need for switching programs throughout the day. For Advanced Bionics recipients, the T-Mic offers significantly improved performance in noise and is recommended for everyday use in all listening environments. PMID:20807480
Parametric model of the scala tympani for haptic-rendered cochlear implantation.
Todd, Catherine; Naghdy, Fazel
2005-01-01
A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.
Music Therapy for Preschool Cochlear Implant Recipients
Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya
2010-01-01
This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691
2014-01-01
2013b), increase expression of deafness genes (Valiyaveettil et al., 2012), and alter cochlear blood flow (Chen et al., 2013b), as well as result in...Intense noise exposure has been shown to reduce partial oxygen pressure and cochlear blood flow (Scheibe et al., 1992, 1993, Lamm and Arnold, 1999...found in the cochlear microvasculature and spiral ganglia (Gosepath, 1997; Franz, 1996) and has been shown to maintain cerebral blood flow and blood
Some considerations concerning cochlear implantation in IFACF-ORL
Hainarosie, M; Zainea, V; Serban, S; Georgescu, MG; Hainarosie, R; Marinescu, A; Georgescu, G
2014-01-01
The article analyzes the patients who have received a cochlear implant at “Prof. Dr. Dorin Hociota” Institute of Phonoaudiology and Functional ENT Surgery, Bucharest, over a period of 13 years, from the beginning of this program in the year 2000. It presents the types of devices used, the particularities of the patients, the surgical techniques and the outcome, critically analyzing the complications encountered. The authors’ comments on the selection of patient protocol, surgical intraoperative challenges and cochlear implant technologies and capabilities are presented. PMID:25870683
Öztürk, Erkan; Doruk, Can; Orhan, Kadir Serkan; Çelik, Mehmet; Polat, Beldan; Güldiken, Yahya
2017-06-01
Cochlear implants are mechanical devices used for patients with severe sensory-neural hearing loss, which has an inner magnet. It is proven that 1.5 Tesla magnetic resonance imaging (MRI) scanners are safe to use in patients with cochlear implant. In our patient, the authors aim to introduce a rare complication caused after a 1.5 Tesla MRI scanning and the management of this situation; the reversion of the magnet of the implant without displacement and significance of surgery in management.
Benefits and Risks of Cochlear Implants
... The cochlear implant stimulates the nerves directly with electrical currents. Although this stimulation appears to be safe, the long term effect of these electrical currents on the nerves is unknown. May not ...
Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies
Busi, Micol; Rosignoli, Monica; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Martini, Alessandro
2015-01-01
Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a negative prognostic factor that is made worse by the concomitant presence of cochlear malformations. Common cavity and stenosis of the internal auditory canal (less than 2 mm) are negative prognostic factors even if brain lesions are absent. PMID:26236732
Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies.
Busi, Micol; Rosignoli, Monica; Castiglione, Alessandro; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Granieri, Enrico; Martini, Alessandro
2015-01-01
Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a negative prognostic factor that is made worse by the concomitant presence of cochlear malformations. Common cavity and stenosis of the internal auditory canal (less than 2 mm) are negative prognostic factors even if brain lesions are absent.
Cochlear Implantation in Older Adults
Lin, Frank R.; Chien, Wade W.; Li, Lingsheng; Niparko, John K.; Francis, Howard W.
2012-01-01
Cochlear implants allow individuals with severe-to-profound hearing loss access to sound and spoken language. The number of older adults in the United States who are potential candidates for cochlear implantation is approximately 150,000 and will continue to increase with the aging of the population. Should cochlear implantation (CI) be routinely recommended for these older adults, and do these individuals benefit from CI? We reviewed our 12 year experience with cochlear implantation in adults ≥60 years (n = 445) at Johns Hopkins to investigate the impact of CI on speech understanding and to identify factors associated with speech performance. Complete data on speech outcomes at baseline and 1 year post-CI were available for 83 individuals. Our results demonstrate that cochlear implantation in adults ≥60 years consistently improved speech understanding scores with a mean increase of 60. 0% (S. D. 24. 1) on HINT sentences in quiet . The magnitude of the gain in speech scores was negatively associated with age at implantation such that for every increasing year of age at CI the gain in speech scores was 1. 3 percentage points less (95% CI: 0. 6 – 1. 9) after adjusting for age at hearing loss onset. Conversely, individuals with higher pre-CI speech scores (HINT scores between 40–60%) had significantly greater post-CI speech scores by a mean of 10. 0 percentage points (95% CI: 0. 4 – 19. 6) than those with lower pre-CI speech scores (HINT <40%) after adjusting for age at CI and age at hearing loss onset. These results suggest that older adult CI candidates who are younger at implantation and with higher preoperative speech scores obtain the highest speech understanding scores after cochlear implantation with possible implications for current Medicare policy. Finally, we provide an extended discussion of the epidemiology and impact of hearing loss in older adults. Future research of CI in older adults should expand beyond simple speech outcomes to take into account the broad cognitive, social, and physical functioning outcomes that are likely detrimentally impacted by hearing loss and may be mitigated by cochlear implantation. PMID:22932787
Auditory cortical responses in patients with cochlear implants
Burdo, S; Razza, S; Di Berardino, F; Tognola, G
2006-01-01
Summary Currently, the most commonly used electrophysiological tests for cochlear implant evaluation are Averaged Electrical Voltages (AEV), Electrical Advisory Brainstem Responses (EABR) and Neural Response Telemetry (NRT). The present paper focuses on the study of acoustic auditory cortical responses, or slow vertex responses, which are not widely used due to the difficulty in recording, especially in young children. Aims of this study were validation of slow vertex responses and their possible applications in monitoring postimplant results, particularly restoration of hearing and auditory maturation. In practice, the use of tone-bursts, also through hearing aids or cochlear implants, as in slow vertex responses, allows many more frequencies to be investigated and louder intensities to be reached than with other tests based on a click as stimulus. Study design focused on latencies of N1 and P2 slow vertex response peaks in cochlear implants. The study population comprised 45 implant recipients (aged 2 to 70 years), divided into 5 different homogeneous groups according to chronological age, age at onset of deafness, and age at implantation. For each subject, slow vertex responses and free-field auditory responses (PTAS) were recorded for tone-bursts at 500 and 2000 Hz before cochlear implant surgery (using hearing aid amplification) and during scheduled sessions at 3rd and 12th month after implant activation. Results showed that N1 and P2 latencies decreased in all groups starting from 3rd through 12th month after activation. Subjects implanted before school age or at least before age 8 yrs showed the widest latency changes. All subjects showed a reduction in the gap between subjective thresholds (obtained with free field auditory responses) and objective thresholds (obtained with slow vertex responses), obtained in presurgery stage and after cochlear implant. In conclusion, a natural evolution of neurophysiological cortical activities of the auditory pathway, over time, was found especially in young children with prelingual deafness and implanted in preschool age. Cochlear implantation appears to provide hearing restoration, demonstrated by the sharp reduction of the gap between subjective free field auditory responses and slow vertex responses threshold obtained with hearing aids vs. cochlear implant. PMID:16886849
Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego
2014-03-01
To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.
Sanderson, Georgina; Ariyaratne, Thathya V; Wyss, Josephine; Looi, Valerie
2014-01-01
Currently, there is a paucity of data concerning the long-term outcomes, educational placement and quality of life of children implanted with hearing devices from large and representative samples of the population. To address this concern, a large, prospective, multicentre, multinational patient-outcomes registry for paediatric recipients of implantable hearing devices was developed. The benefits of this registry, its approach and methodology are described. The Cochlear(™) Paediatric Implanted Recipient Observational Study (Cochlear P-IROS) is a prospective international patient-outcomes registry for children who are implanted in routine clinical practice with one or more hearing devices. The study aims to collect data on patient comorbidities, device use, auditory performance, quality of life and health-related utilities, across different types of implantable hearing devices from a range of manufacturers. Patients will be evaluated with a set of standardised and non-standardised questionnaires prior to initial device activation (baseline) and at six-monthly follow-up intervals up to 24 months and annually thereafter. The Cochlear P-IROS utilises a secure web interface to administer electronic case report forms to clinicians and families of implanted children. The web interface is currently available in five languages: English, Japanese, Korean, Mandarin and Russian. The interface also provides printable versions of the case report forms translated into 22 local languages for collection of data prior to entry online; additional languages may be added, as required. Participation in the Cochlear P-IROS registry is investigator-driven and voluntary. To date, the Cochlear P-IROS has recruited implant clinics across Australia, China, India, Indonesia, Turkey and Vietnam. The registry also aims to recruit multiple clinics in Cuba, Israel, Japan, Malaysia, Singapore, South Africa, South Korea and Russia. The use of a registry such as the Cochlear P-IROS will generate valuable data to support research interests of academics and clinicians around the globe. The data generated will be relevant for a wide range of stakeholders including regulators, payers, providers, policy makers, patients and their families, each with a different perspective for the acceptance and adoption of implantable hearing devices for the treatment of hearing loss.
A speech processing study using an acoustic model of a multiple-channel cochlear implant
NASA Astrophysics Data System (ADS)
Xu, Ying
1998-10-01
A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and channel numbers were not beneficial. Manipulations of stimulation rate and number of activated channels did not appreciably affect consonant recognition. These results suggest that overall speech performance may improve by appropriately increasing stimulation rate and number of activated channels. Future revision of this acoustic model is necessary to provide more accurate amplitude representation of speech.
NASA Astrophysics Data System (ADS)
Liu, Tzu-Chi; Wu, Hau-Tieng; Chen, Ya-Hui; Chen, Ya-Han; Fang, Te-Yung; Wang, Pa-Chun; Liu, Yi-Wen
2018-05-01
The presence of click-evoked (CE) otoacoustic emissions (OAEs) has been clinically accepted as an indicator of normal cochlear processing of sounds. For treatment and diagnostic purposes, however, clinicians do not typically pay attention to the detailed spectrum and waveform of CEOAEs. A possible reason is due to the lack of noise-robust signal processing tools to estimate physiologically meaningful time-frequency properties of CEOAEs, such as the latency of spectral components. In this on-going study, we applied a modern tool called concentration of frequency and time (ConceFT, [1]) to analyze CEOAE waveforms. Randomly combined orthogonal functions are used as windowing functions for time-frequency analysis. The resulting spectrograms are subject to nonlinear time-frequency reassignment so as to enhance the concentration of time-varying sinusoidal components. The results after reassignment could be further averaged across the random choice of windows. CEOAE waveforms are acquired by a linear averaging paradigm, and longitudinal data are currently being collected from patients with Ménière's disease (MD) and a control group of normal hearing subjects. When CEOAE is present, the ConceFT plots show traces of decreasing but fluctuating instantaneous frequency against time. For comparison purposes, same processing methods are also applied to analyze CEOAE data from cochlear mechanics simulation.
Lee, Jong Joo; Jang, Jeong Hun; Choo, Oak-Sung; Lim, Hye Jin; Choung, Yun-Hoon
2018-01-01
Steroids have been widely used to treat inner-ear diseases such as sudden sensorineural hearing loss, tinnitus, and Meniere's disease. They can be given via either systemic or intratympanic (IT) injection. The purpose of the present study was to explore differences in intracochlear steroid distribution by the administration method employed (systemic vs. IT injection). Animal study. Twenty-three Sprague-Dawley rats were given fluorescein isothiocyanate-labeled dexamethasone (FITC-DEX) three times (on successive days) via intraperitoneal (IP) or IT injection. Cochlear uptake of FITC-DEX was evaluated via immunohistochemistry and flow cytometry at 6 hours, and 3 and 7 days after the final injection. FITC-DEX uptake was evident in spiral ganglion cells (SGs), the organ of Corti (OC), and the lateral walls (LWs), the basal turns of which were stained relatively prominently in both groups. Animals receiving IP injections exhibited higher FITC-DEX uptakes by the SGs and OC, whereas IT injection triggered higher-level FITC-DEX accumulation by the OC and LWs. Flow cytometry revealed that intracochlear FITC-DEX uptake by IT-injected animals was higher and more prolonged than in animals subjected to IP injections. We thus describe differences in cochlear steroid distributions after systemic and IT injections. This finding could help our understanding of the pharmacokinetics of steroids in the cochlea. NA. Laryngoscope, 128:189-194, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
..., including cochlear implants, deep brain stimulators, hydrocephalus shunts, spinal cord stimulators, and... pediatric populations, including cochlear implants, deep brain stimulators, hydrocephalus shunts, spinal...
Changes in the inner ear structures in cystic fibrosis patients.
Pauna, Henrique F; Monsanto, Rafael C; Kurata, Natsuko; Paparella, Michael M; Cureoglu, Sebahattin
2017-01-01
Although prolonged use of antibiotics is very common in cystic fibrosis (CF) patients, no studies have assessed the changes in both cochlear and peripheral vestibular systems in this population. We used human temporal bones to analyze the density of vestibular dark, transitional, and hair cells in specimens from CF patients who were exposed to several types of antibiotics, as compared with specimens from an age-matched control group with no history of ear disease or antibiotic use. Additionally, we analyzed the changes in the elements of the cochlea (hair cells, spiral ganglion neurons, and the area of the stria vascularis). Data was gathered using differential interference contrast microscopy and light microscopy. In the CF group, 83% of patients were exposed to some ototoxic drugs, such as aminoglycosides. As compared with the control group, the density of both type I and type II vestibular hair cells was significantly lower in all structures analyzed; the number of dark cells was significantly lower in the lateral and posterior semicircular canals. We noted a trend toward a lower number of both inner and outer cochlear hair cells at all turns of the cochlea. The number of spiral ganglion neurons in Rosenthal's canal at the apical turn of the cochlea was significantly lower; furthermore, the area of the stria vascularis at the apical turn of the cochlea was significantly smaller. Deterioration of cochlear and vestibular structures in CF patients might be related to their exposure to ototoxic antibiotics. Well-designed case-control studies are necessary to rule out the effect of CF itself. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Changes in the Inner Ear Structures in Cystic Fibrosis Patients
Pauna, Henrique F.; Monsanto, Rafael C.; Kurata, Natsuko; Paparella, Michael M.; Cureoglu, Sebahattin
2016-01-01
Objective Although prolonged use of antibiotics is very common in cystic fibrosis (CF) patients, no studies have assessed the changes in both cochlear and peripheral vestibular systems in this population. Methods We used human temporal bones to analyze the density of vestibular dark, transitional, and hair cells in specimens from CF patients who were exposed to several types of antibiotics, as compared with specimens from an age-matched control group with no history of ear disease or antibiotic use. Additionally, we analyzed the changes in the elements of the cochlea (hair cells, spiral ganglion neurons, and the area of the stria vascularis). Data was gathered using differential interference contrast microscopy and light microscopy. Results In the CF group, 83% of patients were exposed to some ototoxic drugs, such as aminoglycosides. As compared with the control group, the density of both type I and type II vestibular hair cells was significantly lower in all structures analyzed; the number of dark cells was significantly lower in the lateral and posterior semicircular canals. We noted a trend toward a lower number of both inner and outer cochlear hair cells at all turns of the cochlea. The number of spiral ganglion neurons in Rosenthal’s canal at the apical turn of the cochlea was significantly lower; furthermore, the area of the stria vascularis at the apical turn of the cochlea was significantly smaller. Conclusions Deterioration of cochlear and vestibular structures in CF patients might be related to their exposure to ototoxic antibiotics. Well-designed case-control studies are necessary to rule out the effect of CF itself. PMID:28012509
Wingard, Jeffrey C.; Zhao, Hong-Bo
2015-01-01
Hearing loss due to mutations in the connexin gene family, which encodes gap junctional proteins, is a common form of hereditary deafness. In particular, connexin 26 (Cx26, GJB2) mutations are responsible for ~50% of non-syndromic hearing loss, which is the highest incidence of genetic disease. In the clinic, Cx26 mutations cause various auditory phenotypes ranging from profound congenital deafness at birth to mild, progressive hearing loss in late childhood. Recent experiments demonstrate that congenital deafness mainly results from cochlear developmental disorders rather than hair cell degeneration and endocochlear potential reduction, while late-onset hearing loss results from reduction of active cochlear amplification, even though cochlear hair cells have no connexin expression. However, there is no apparent, demonstrable relationship between specific changes in connexin (channel) functions and the phenotypes of mutation-induced hearing loss. Moreover, new experiments further demonstrate that the hypothesized K+-recycling disruption is not a principal deafness mechanism for connexin deficiency induced hearing loss. Cx30 (GJB6), Cx29 (GJC3), Cx31 (GJB3), and Cx43 (GJA1) mutations can also cause hearing loss with distinct pathological changes in the cochlea. These new studies provide invaluable information about deafness mechanisms underlying connexin mutation-induced hearing loss and also provide important information for developing new protective and therapeutic strategies for this common deafness. However, the detailed cellular mechanisms underlying these pathological changes remain unclear. Also, little is known about specific mutation-induced pathological changes in vivo and little information is available for humans. Such further studies are urgently required. PMID:26074771
Cochlear Implants (For Parents)
... nerve, and send it to the brain. The cochlear implant package is made up of: a receiver-stimulator that contains all of the electronic circuits that control the flow of electrical pulses into the ear an antenna ...
Are There Treatments That Can Help Me?
... tinnitus in a significant number of study volunteers. Cochlear implants are sometimes used in people who have tinnitus along with severe hearing loss. A cochlear implant bypasses the damaged portion of the inner ...
Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C
2000-01-01
Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel
Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.
Musser, Alexander B; Golub, Justin S; Samy, Ravi N; Phero, James C
2016-01-01
To report a rare case of cerebrospinal fluid gusher and subsequent seizure immediately after cochlear implant electrode insertion. After the cochlear implant electrode was inserted, brisk flow of 10 mL of cerebrospinal fluid was seen. The electrode was promptly inserted and the leak was additionally sealed with fascia. Seconds later, the patient had a tonic-clonic seizure lasting 30 seconds. Two additional episodes occurred during the case. Her postoperative course was uneventful with no subsequent seizures. The device has been successfully activated. Intervention & Technique: Postoperative imaging showed correct intracochlear placement of the electrode as well as an incidental enlarged vestibular aqueduct. Neurology consultation including electroencephalogram was unremarkable. To our knowledge, this is the first report of a seizure temporally associated with cochlear implant electrode insertion. The significance and possible casual relationship between these two events is discussed.
The early days of the multi channel cochlear implant: efforts and achievement in France.
Chouard, C H
2015-04-01
On September 10th 2013, the clinical medical research Lasker award winners were rewarded for their work on multichannel cochlear implant. It has been my pleasure to see that such a major topic had caught the attention of the Members of the Jury for this prestigious award. That is why I accepted an invitation to participate in a special issue of Hearing Research devoted to the three winners. Here I highlight four scientific contributions made by the French team in late 1970s and early 1980s to modern multichannel cochlear implant development. 1) Chouard and MacLeod plotted an approximate frequency map of the whole length of the human cochlea, including its "hidden face" corresponding to speech frequencies. Moreover MacLeod suggested a sequential display of electrical stimulation as a function of each electrode, a precursor to today's electrodogram and interleaved stimulation. 2) Chouard performed total cochlear implantation in a deaf adult male with 8 electrically independent electrodes that were evenly distributed along the cochlea. 3) Chouard and MacLeod described in a patent detailed sound signal processing for a functional multichannel cochlear implant and reported speech discrimination without help of lip reading in some totally deafened patients. 4) Chouard experimentally demonstrated in the guinea pig the advantage of early cochlear implantation in treating profound neonatal deafness. This article is part of a Special Issue entitled
Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.
Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter
2004-07-01
A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.
Cejas, Ivette; Hoffman, Michael F; Quittner, Alexandra L
2015-01-01
The number of children with hearing loss with additional disabilities receiving cochlear implantation has increased dramatically over the past decade. However, little is known about their auditory and speech and language development following implantation. The purpose of this review is to evaluate the effects of cochlear implantation on the most common genetic and developmental disorders in children with hearing loss. Benefits of cochlear implantation for children with autism spectrum disorder, developmental delay, CHARGE syndrome, cerebral palsy, learning disorders, Usher syndrome, Waardenburg syndrome, and attention deficit/hyperactivity disorder are reviewed. Our review indicates that children with hearing loss and additional disabilities benefit from cochlear implantation, especially when implanted early. Thus, early interventions seem as important for these children as for deaf children without additional disabilities. Comparisons of outcomes across these disabilities indicate that children with little to no cognitive impairment (eg, Waardenburg sydrome, attention deficit hyperactivity disorder) have better outcomes than those with greater deficits in intellectual functioning (eg, autism, CHARGE syndrome). In addition, parents of children with hearing loss and additional disabilities report higher levels of parenting stress and greater child behavior problems than those without comorbid diagnoses. However, these parents are as sensitive when interacting with their children as parents with typically developing children using cochlear implantation. Given these results, it is critical to evaluate these children's developmental milestones to provide early implantation and intervention, appropriately counsel families regarding realistic expectations for the implant, and facilitate family adaptation.
Cejas, Ivette; Hoffman, Michael F; Quittner, Alexandra L
2015-01-01
The number of children with hearing loss with additional disabilities receiving cochlear implantation has increased dramatically over the past decade. However, little is known about their auditory and speech and language development following implantation. The purpose of this review is to evaluate the effects of cochlear implantation on the most common genetic and developmental disorders in children with hearing loss. Benefits of cochlear implantation for children with autism spectrum disorder, developmental delay, CHARGE syndrome, cerebral palsy, learning disorders, Usher syndrome, Waardenburg syndrome, and attention deficit/hyperactivity disorder are reviewed. Our review indicates that children with hearing loss and additional disabilities benefit from cochlear implantation, especially when implanted early. Thus, early interventions seem as important for these children as for deaf children without additional disabilities. Comparisons of outcomes across these disabilities indicate that children with little to no cognitive impairment (eg, Waardenburg sydrome, attention deficit hyperactivity disorder) have better outcomes than those with greater deficits in intellectual functioning (eg, autism, CHARGE syndrome). In addition, parents of children with hearing loss and additional disabilities report higher levels of parenting stress and greater child behavior problems than those without comorbid diagnoses. However, these parents are as sensitive when interacting with their children as parents with typically developing children using cochlear implantation. Given these results, it is critical to evaluate these children’s developmental milestones to provide early implantation and intervention, appropriately counsel families regarding realistic expectations for the implant, and facilitate family adaptation. PMID:29388595
Speech Intelligibility and Prosody Production in Children with Cochlear Implants
Chin, Steven B.; Bergeson, Tonya R.; Phan, Jennifer
2012-01-01
Objectives The purpose of the current study was to examine the relation between speech intelligibility and prosody production in children who use cochlear implants. Methods The Beginner's Intelligibility Test (BIT) and Prosodic Utterance Production (PUP) task were administered to 15 children who use cochlear implants and 10 children with normal hearing. Adult listeners with normal hearing judged the intelligibility of the words in the BIT sentences, identified the PUP sentences as one of four grammatical or emotional moods (i.e., declarative, interrogative, happy, or sad), and rated the PUP sentences according to how well they thought the child conveyed the designated mood. Results Percent correct scores were higher for intelligibility than for prosody and higher for children with normal hearing than for children with cochlear implants. Declarative sentences were most readily identified and received the highest ratings by adult listeners; interrogative sentences were least readily identified and received the lowest ratings. Correlations between intelligibility and all mood identification and rating scores except declarative were not significant. Discussion The findings suggest that the development of speech intelligibility progresses ahead of prosody in both children with cochlear implants and children with normal hearing; however, children with normal hearing still perform better than children with cochlear implants on measures of intelligibility and prosody even after accounting for hearing age. Problems with interrogative intonation may be related to more general restrictions on rising intonation, and the correlation results indicate that intelligibility and sentence intonation may be relatively dissociated at these ages. PMID:22717120
Kumar, Joish Upendra; Kavitha, Y
2017-02-01
With the use of various surgical techniques, types of implants, the preoperative assessment of cochlear dimensions is becoming increasingly relevant prior to cochlear implantation. High resolution CISS protocol MRI gives a better assessment of membranous cochlea, cochlear nerve, and membranous labyrinth. Curved Multiplanar Reconstruction (MPR) algorithm provides better images that can be used for measuring dimensions of membranous cochlea. To ascertain the value of curved multiplanar reconstruction algorithm in high resolution 3-Dimensional T2 Weighted Gradient Echo Constructive Interference Steady State (3D T2W GRE CISS) imaging for accurate morphometry of membranous cochlea. Fourteen children underwent MRI for inner ear assessment. High resolution 3D T2W GRE CISS sequence was used to obtain images of cochlea. Curved MPR reconstruction algorithm was used to virtually uncoil the membranous cochlea on the volume images and cochlear measurements were done. Virtually uncoiled images of membranous cochlea of appropriate resolution were obtained from the volume data obtained from the high resolution 3D T2W GRE CISS images, after using curved MPR reconstruction algorithm mean membranous cochlear length in the children was 27.52 mm. Maximum apical turn diameter of membranous cochlea was 1.13 mm, mid turn diameter was 1.38 mm, basal turn diameter was 1.81 mm. Curved MPR reconstruction algorithm applied to CISS protocol images facilitates in getting appropriate quality images of membranous cochlea for accurate measurements.
Guerra-Jiménez, Gloria; Viera Artiles, Jaime; Mateos, Mar; González Aguado, Rocío; Falcón González, Juan Carlos; Borkoski Barreiro, Silvia; Ramos Macías, Angel
2013-01-01
Some studies suggest that simultaneous or sequential cochlear implantation in a short period of time offers additional benefits. There is controversy regarding the existence of an age limit after which a second implantation offers less benefit for the acquisition of communication skills. The objectives of this study were to confirm that sequential cochlear implantation offers benefits compared to unilateral implantation and to study whether, at 12 years of age, there are significant differences regarding the age at the time of the second implantation. Descriptive and observational study of a population of 12-year-old children carrying cochlear implants (n=69). A liminal pure tone audiometry and an open-field verbal discrimination test (disyllables, common phrases in an open context, with and without noise) were conducted to evaluate audiological benefits. Verbal discrimination results were better among patients who had been implanted before the age of 2 years, although the differences were not statistically significant (P>.5). Children who had received bilateral cochlear implants before the age of 2 years and with a period less than 4 years between both implants presented better verbal discrimination percentages (P<.05). In our sample, early cochlear implantation with a short period between both implants provided significant benefits regarding intelligibility. There seem to be a specific age and interimplant period, after which the auditory benefit on the first implant becomes reduced. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Assessment of Appalachian region pediatric hearing healthcare disparities and delays.
Bush, Matthew L; Osetinsky, Mariel; Shinn, Jennifer B; Gal, Thomas J; Ding, Xiuhua; Fardo, David W; Schoenberg, Nancy
2014-07-01
The purpose of this study was to examine the timing of diagnostic and therapeutic services in cochlear implant recipients from a rural Appalachian region with healthcare disparity. Retrospective analysis. Cochlear implant recipients from a tertiary referral center born with severe congenital sensorineural hearing loss were examined. Rural status and Appalachian status of their county of origin were recorded. A log-rank test was used to examine differences in the distributions of time to definitive diagnosis of hearing loss, initial amplification fitting, and cochlear implantation in these children. Correlation analysis of the rural status of each county and the timing of services was assessed. A total of 53 children born with congenital hearing loss were included in the study (36 from rural counties and 17 from urban/suburban counties). The distribution of weeks after birth to diagnosis (P=.006), amplification (P=.030), and cochlear implantation (P=.002) was delayed in rural children compared with urban children. An analysis factoring in the effect of implementation of mandatory infant hearing screening in 2000 demonstrated a similar delay in rural children for weeks to diagnosis (P=.028), amplification (P=.087), and cochlear implantation (P<.0001). Children with severe hearing loss in very rural areas, such as Appalachia, may have significant delays in diagnostic and rehabilitative services. Further investigation is warranted to assess causative factors in delays of cochlear implantation and to develop interventions to promote timely diagnosis and care. 3b. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Sampath Kumar, Raghunandhan; Kameswaran, Mohan
2018-06-01
The overall prevalence of deafness in India is 0.2%, but the prevalence in the southern state of Tamil Nadu is much higher (around 0.6%) because of consanguinity. Especially in India, establishing cochlear implantation as a treatment modality for hearing loss has been a daunting task, but in the last decade, the cochlear implantation program has emerged as an unqualified success in many states, with over 20 000 cochlear implantations done till date. Several states are sponsoring free implants to children under the age of 6 years and below poverty line. Nearly 3000 cochlear implantations have been performed in Tamil Nadu under the Chief Minister's Comprehensive Health Insurance Scheme, with the goal to have a 'deafness free Tamil Nadu' by 2025. This scheme covers nearly 40 million people in rural areas. Valuable lessons have been learnt from this social experiment. One of the cornerstones of this scheme is the method to deliver habilitation via satellite centers in rural areas at the doorstep of the patient. The outcomes in peripheral centers were found to be statistically similar to those in the main center and correlated well with duration of habilitation. Opening up satellite centers for habilitation across the state of Tamil Nadu has greatly helped to improve the attendance and outcomes. The Indian model has been hugely successful and has helped start similar cochlear implantation programs in neighboring countries such as Nepal, Sri Lanka and Bangladesh.
Escorihuela García, Vicente; Pitarch Ribas, María Ignacia; Llópez Carratalá, Ignacio; Latorre Monteagudo, Emilia; Morant Ventura, Antonio; Marco Algarra, Jaime
2016-01-01
The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localization and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducted a statistical comparison of both groups in the audiometry, IT-Mais, Nottingham, LittlEars scales and verbal tests. No significant differences in hearing thresholds and questionnaires between unilateral and bilateral implantation were detected in either the first or second year. Verbal tests do show statistically significant differences: children with bilateral cochlear implant obtain 100% recognition of disyllabic and phrases within 2-3 years after implantation whilst children with one implant do not obtain those results at 5 years after surgery. No differences between simultaneous and sequential bilateral implantation were detected. We emphasize the importance of ensuring good early audiological screening, to carry out an early and bilateral cochlear implantation with the consequent development of audio-language skills similar to normal hearing children. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Commissural axons of the mouse cochlear nucleus.
Brown, M Christian; Drottar, Marie; Benson, Thane E; Darrow, Keith
2013-05-01
The axons of commissural neurons that project from one cochlear nucleus to the other were studied after labeling with anterograde tracer. Injections were made into the dorsal subdivision of the cochlear nucleus in order to restrict labeling only to the group of commissural neurons that gave off collaterals to, or were located in, this subdivision. The number of labeled commissural axons in each injection was correlated with the number of labeled radiate multipolar neurons, suggesting radiate neurons as the predominant origin of the axons. The radiate commissural axons are thick and myelinated, and they exit the dorsal acoustic stria of the injected cochlear nucleus to cross the brainstem in the dorsal half, near the crossing position of the olivocochlear bundle. They enter the opposite cochlear nucleus via the dorsal and ventral acoustic stria and at its medial border. Reconstructions of single axons demonstrate that terminations are mostly in the core and typically within a single subdivision of the cochlear nucleus. Extents of termination range from narrow to broad along both the dorsoventral (i.e., tonotopic) and the rostrocaudal dimensions. In the electron microscope, labeled swellings form synapses that are symmetric (in that there is little postsynaptic density), a characteristic of inhibitory synapses. Our labeled axons do not appear to include excitatory commissural axons that end in edge regions of the nucleus. Radiate commissural axons could mediate the broadband inhibition observed in responses to contralateral sound, and they may balance input from the two ears with a quick time course. Copyright © 2012 Wiley Periodicals, Inc.
Commissural Axons of the Mouse Cochlear Nucleus
Brown, M. Christian; Drottar, Marie; Benson, Thane E.; Darrow, Keith
2012-01-01
The axons of commissural neurons that project from one cochlear nucleus to the other were studied after labeling with anterograde tracer. Injections were made into the dorsal subdivision of the cochlear nucleus in order to restrict labeling only to the group of commissural neurons that gave off collaterals to, or were located in, this subdivision. The number of labeled commissural axons in each injection was correlated with the number of labeled radiate multipolar neurons, suggesting radiate neurons as the predominant origin of the axons. The radiate commissural axons are thick and myelinated, and they exit the dorsal acoustic stria of the injected cochlear nucleus to cross the brainstem in the dorsal half, near the crossing position of the olivocochlear bundle. They enter the opposite cochlear nucleus via the dorsal and ventral acoustic stria and at its medial border. Reconstructions of single axons demonstrate that terminations are mostly in the core and typically within a single subdivision of the cochlear nucleus. Extents of termination range from narrow to broad along both the dorso-ventral (i.e. tonotopic) and rostro-caudal dimensions. In the electron microscope, labeled swellings form synapses that are symmetric (in that there is little postsynaptic density), a characteristic of inhibitory synapses. Our labeled axons do not appear to include excitatory commissural axons that end in edge regions of the nucleus. Radiate commissural axons could mediate the broad-band inhibition observed in responses to contralateral sound, and they may balance input from the two ears on a quick time course. PMID:23124982
NASA Astrophysics Data System (ADS)
Ravicz, Michael E.; Cho, Nam-Hyun; Maftoon, Nima; Puria, Sunil
2018-05-01
Recent developments in Optical Coherence Tomography (OCT) allow measurements of cochlear motions through the bony cochlear wall without holes at spatial resolutions approaching about 10 µm. Measurements to date have been made with custom OCT systems with long development times. We present measurements made with a commercial OCT system driven by custom software (VibOCT) that facilitates near real-time frequency response measurements. The 905-nm wavelength laser and high-speed (100 kHz) camera provide higher axial resolution (3 µm in air) and temporal resolution than previous studies and a sub-nanometer noise floor in air. We gathered anatomical images of the gerbil cochlear apex in vivo at higher resolution than available previously, sufficient to resolve individual outer hair cells, pillar cells, tunnel of Corti and inner sulcus regions. Images from the 3rd apical turn show a bulging of Reissners membrane in vivo that flattened post-mortem with a concomitant reduction in the distance between the Henson cell border and the stria vascularis wall. Vibrometry of the organ of Corti shows a low-pass characteristic in-vivo and post-mortem with a traveling wave-like phase delay similar to a recent study rather than the sharp tuning seen more basally. This system can provide valuable information on cochlear function, which is also useful for the development of detailed cochlear models of the passive and active gerbil apex.
Modelling the effect of round window stiffness on residual hearing after cochlear implantation.
Elliott, Stephen J; Ni, Guangjian; Verschuur, Carl A
2016-11-01
Preservation of residual hearing after cochlear implantation is now considered an important goal of surgery. However, studies indicate an average post-operative hearing loss of around 20 dB at low frequencies. One factor which may contribute to post-operative hearing loss, but which has received little attention in the literature to date, is the increased stiffness of the round window, due to the physical presence of the cochlear implant, and to its subsequent thickening or to bone growth around it. A finite element model was used to estimate that there is approximately a 100-fold increase in the round window stiffness due to a cochlear implant passing through it. A lumped element model was then developed to study the effects of this change in stiffness on the acoustic response of the cochlea. As the round window stiffness increases, the effects of the cochlear and vestibular aqueducts become more important. An increase of round window stiffness by a factor of 10 is predicted to have little effect on residual hearing, but increasing this stiffness by a factor of 100 reduces the acoustic sensitivity of the cochlea by about 20 dB, below 1 kHz, in reasonable agreement with the observed loss in residual hearing after implantation. It is also shown that the effect of this stiffening could be reduced by incorporating a small gas bubble within the cochlear implant. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Hixon, Brian; Chan, Stephen; Adkins, Margaret; Shinn, Jennifer B.; Bush, Matthew L.
2016-01-01
Objective The purpose of this study is to compare the timing and impact of hearing healthcare of rural and urban adults with severe hearing loss who use cochlear implants (CI). Study Design Cross-sectional questionnaire study Setting Tertiary referral center Patients Adult cochlear implant recipients. Main Outcome Measures Data collected included county of residence, socioeconomic information, impact of hearing loss on education/employment, and timing of hearing loss treatment. The benefits obtained from cochlear implantation were also evaluated. Results There were 91 participants (32 from urban counties, 26 from moderately rural counties, and 33 for extremely rural counties). Rural participants have a longer commute time to the CI center (p<0.001), lower income (p<0.001) and higher percentage of Medicaid coverage (p=0.004). Compared with urban-metro participants, rural participants with gradually progressive hearing loss had a greater time interval from the onset of hearing loss to obtaining hearing aid amplification (10 years versus 5 years, p=0.04). There was also a greater time interval from onset of hearing loss to the time of cochlear implantation in rural participants (p=0.04). Reported job loss was higher in rural participants than in urban participants (p=0.05). Both groups reported comparable benefit from cochlear implantation. Conclusions Rural CI recipients differ from urban residents in socioeconomic characteristics and may be delayed in timely treatment of hearing loss. Further efforts to expand access to hearing healthcare services may benefit rural adult patients. PMID:27636389
Hixon, Brian; Chan, Stephen; Adkins, Margaret; Shinn, Jennifer B; Bush, Matthew L
2016-10-01
The purpose of this study is to compare the timing and impact of hearing healthcare of rural and urban adults with severe hearing loss who use cochlear implants (CI). Cross-sectional questionnaire study. Tertiary referral center. Adult cochlear implant recipients. Data collected included county of residence, socioeconomic information, impact of hearing loss on education/employment, and timing of hearing loss treatment. The benefits obtained from cochlear implantation were also evaluated. There were 91 participants (32 from urban counties, 26 from moderately rural counties, and 33 for extremely rural counties). Rural participants have a longer commute time to the CI center (p < 0.001), lower income (p < 0.001), and higher percentage of Medicaid coverage (p = 0.004). Compared with urban-metro participants, rural participants with gradually progressive hearing loss had a greater time interval from the onset of hearing loss to obtaining hearing aid amplification (10 yr versus 5 yr, p = 0.04). There was also a greater time interval from onset of hearing loss to the time of cochlear implantation in rural participants (p = 0.04). Reported job loss was higher in rural participants than in urban participants (p = 0.05). Both groups reported comparable benefit from cochlear implantation. Rural CI recipients differ from urban residents in socioeconomic characteristics and may be delayed in timely treatment of hearing loss. Further efforts to expand access to hearing healthcare services may benefit rural adult patients.
Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.
Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi
2012-01-01
Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.
Technological, biological, and acoustical constraints to music perception in cochlear implant users.
Limb, Charles J; Roy, Alexis T
2014-02-01
Despite advances in technology, the ability to perceive music remains limited for many cochlear implant users. This paper reviews the technological, biological, and acoustical constraints that make music an especially challenging stimulus for cochlear implant users, while highlighting recent research efforts to overcome these shortcomings. The limitations of cochlear implant devices, which have been optimized for speech comprehension, become evident when applied to music, particularly with regards to inadequate spectral, fine-temporal, and dynamic range representation. Beyond the impoverished information transmitted by the device itself, both peripheral and central auditory nervous system deficits are seen in the presence of sensorineural hearing loss, such as auditory nerve degeneration and abnormal auditory cortex activation. These technological and biological constraints to effective music perception are further compounded by the complexity of the acoustical features of music itself that require the perceptual integration of varying rhythmic, melodic, harmonic, and timbral elements of sound. Cochlear implant users not only have difficulty perceiving spectral components individually (leading to fundamental disruptions in perception of pitch, melody, and harmony) but also display deficits with higher perceptual integration tasks required for music perception, such as auditory stream segregation. Despite these current limitations, focused musical training programs, new assessment methods, and improvements in the representation and transmission of the complex acoustical features of music through technological innovation offer the potential for significant advancements in cochlear implant-mediated music perception. Copyright © 2013 Elsevier B.V. All rights reserved.
Wired to freedom: Life science, public politics, and the case of Cochlear Implantation.
Jepsen, Kim Sune; Bertilsson, T Margareta
2017-02-01
Cochlear Implantation is now regarded as the most successful medical technology. It carries promises to provide deaf/hearing impaired individuals with a technological sense of hearing and an access to participate on a more equal level in social life. In this article, we explore the adoption of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being "wired to freedom" that involves new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as "wired to freedom," we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear Implantation. As our empirical observations are largely based in the Scandinavian countries (notably Denmark), we also provide some reflections on the character of the technology-friendly Scandinavian welfare states and the unintended consequences that may follow in the wake of rapid technology implementation of life science in society.
Intracochlear pressure measurements in scala media inform models of cochlear mechanics
NASA Astrophysics Data System (ADS)
Kale, Sushrut; Olson, Elizabeth S.
2015-12-01
In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.
Cochlear Implantation, Enhancements, Transhumanism and Posthumanism: Some Human Questions.
Lee, Joseph
2016-02-01
Biomedical engineering technologies such as brain-machine interfaces and neuroprosthetics are advancements which assist human beings in varied ways. There are exciting yet speculative visions of how the neurosciences and bioengineering may influence human nature. However, these could be preparing a possible pathway towards an enhanced and even posthuman future. This article seeks to investigate several ethical themes and wider questions of enhancement, transhumanism and posthumanism. Four themes of interest are: autonomy, identity, futures, and community. Three larger questions can be asked: will everyone be enhanced? Will we be "human" if we are not, one day, transhuman? Should we be enhanced or not? The article proceeds by concentrating on a widespread and sometimes controversial application: the cochlear implant, an auditory prosthesis implanted into Deaf patients. Cochlear implantation and its reception in both the deaf and hearing communities have a distinctive moral discourse, which can offer surprising insights. The paper begins with several points about the enhancement of human beings, transhumanism's reach beyond the human, and posthuman aspirations. Next it focuses on cochlear implants on two sides. Firstly, a shorter consideration of what technologies may do to humans in a transhumanist world. Secondly, a deeper analysis of cochlear implantation's unique socio-political movement, its ethical explanations and cultural experiences linked with pediatric cochlear implantation-and how those wary of being thrust towards posthumanism could marshal such ideas by analogy. As transhumanism approaches, the issues and questions merit continuing intense analysis.
Kashio, Akinori; Sakamoto, Takashi; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2015-01-01
To predict round window niche (RWN) visibility using high-resolution computed tomography (HRCT). Case series with chart review. Academic tertiary care center. We retrospectively reviewed 70 cochlear implant ears that underwent presurgical axial HRCT with a surgical video recorder. The visibility of the RWN was classified into three types: 17 as invisible or nearly invisible, 22 as partially visible, and 31 as fully visible. Next, we measured the following three radiologic parameters: 1) the angle of the external auditory canal (EAC) relative to the cochlear basal turn, 2) the width of the facial recess, and 3) the relative location of the facial nerve (FN) to the cochlear basal turn. These were compared with the RWN visibility. Subsequently, to predict the RWN visibility, a line was created parallel to the EAC line and along the anterior lateral FN. The location of the line relative to the round window membrane was compared with the RWN view. In cases that had poor RWN visibility, the angle of the posterior canal wall portion of the EAC relative to the cochlear basal turn was significantly smaller and the location of the FN to the cochlear basal turn was closer. The location of the prediction line to the round window membrane highly predicted the RWN view during the surgery. The RWN visibility and the preoperative HRCT findings showed a high correlation. Drawing the prediction line is a simple and useful way for preoperatively predicting the RWN visibility in cochlear implant surgery.
Systemic immunity influences hearing preservation in cochlear implantation.
Souter, Melanie; Eastwood, Hayden; Marovic, Paul; Kel, Gordana; Wongprasartsuk, Sarin; Ryan, Allen F; O'Leary, Stephen John
2012-06-01
To determine whether a systemic immune response influences hearing thresholds and tissue response after cochlear implantation of hearing guinea pigs. Guinea pigs were inoculated with sterile antigen (Keyhole limpet hemocyanin) 3 weeks before cochlear implantation. Pure-tone auditory brainstem response thresholds were performed before implantation and 1 and 4 weeks later. Dexamethasone phosphate 20% was adsorbed onto a hyaluronic acid carboxymethylcellulose sponge and was applied to the round window for 30 minutes before electrode insertion. Normal saline was used for controls. Cochlear histology was performed at 4 weeks after implantation to assess the tissue response to implantation. To control for the effect of keyhole limpet hemocyanin priming, a group of unprimed animals underwent cochlear implantation with a saline-soaked pledget applied to the round window. Keyhole limpet hemocyanin priming had no significant detrimental effect on thresholds without implantation. Thresholds were elevated after implantation across all frequencies tested (2-32 kHz) in primed animals but only at higher frequencies (4-32 kHz) in unprimed controls. In primed animals, dexamethasone treatment significantly reduced threshold shifts at 2 and 8 kHz. Keyhole limpet hemocyanin led to the more frequent observation of lymphocytes in the tissue response to the implant. Systemic immune activation at the time of cochlear implantation broadened the range of frequencies experiencing elevated thresholds after implantation. Local dexamethasone provides partial protection against this hearing loss, but the degree and extent of protection are less compared to previous studies with unprimed animals.
Song, Mee Hyun; Bae, Mi Ran; Kim, Hee Nam; Lee, Won-Sang; Yang, Won Sun; Choi, Jae Young
2010-08-01
Cochlear implantation in patients with narrow internal auditory canal (IAC) can result in variable outcomes; however, preoperative evaluations have limitations in accurately predicting outcomes. In this study, we analyzed the outcomes of cochlear implantation in patients with narrow IAC and correlated the intracochlear electrically evoked auditory brainstem response (EABR) findings to postoperative performance to determine the prognostic significance of intracochlear EABR. Retrospective case series at a tertiary hospital. Thirteen profoundly deaf patients with narrow IAC who received cochlear implantation from 2002 to 2008 were included in this study. Postoperative performance was evaluated after at least 12 months of follow-up, and postoperative intracochlear EABR was measured to determine its correlation with outcome. The clinical significance of electrically evoked compound action potential (ECAP) was also analyzed. Patients with narrow IAC showed postoperative auditory performances ranging from CAP 0 to 4 after cochlear implantation. Intracochlear EABR measured postoperatively demonstrated prognostic value in the prediction of long-term outcomes, whereas ECAP measurements failed to show a significant correlation with outcome. Consistent with the advantages of intracochlear EABR over extracochlear EABR, this study demonstrates that intracochlear EABR has prognostic significance in predicting long-term outcomes in patients with narrow IAC. Intracochlear EABR measured either intraoperatively or in the early postoperative period may play an important role in deciding whether to continue with auditory rehabilitation using a cochlear implant or to switch to an auditory brainstem implant so as not to miss the optimal timing for language development.
Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.
Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S
A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not observed for adults. An additional finding was that SMRT score was negatively correlated with age for adults with implants. Results from this study suggest that basic psychophysical capabilities of early implanted children and postlingually implanted adults differ when assessed in the sound field using their personal implant processors. Because spectral resolution does not improve with age for early implanted children, it seems likely that the sparse representation of the signal provided by a cochlear implant limits spectral resolution development. These results are supported by the finding that postlingually implanted adults, whose auditory systems matured before the onset of hearing loss, perform significantly better than early implanted children on the spectral resolution test.
[DPOAE in tinnitus patients with cochlear hearing loss considering hyperacusis and misophonia].
Sztuka, Aleksandra; Pośpiech, Lucyna; Gawron, Wojciech; Dudek, Krzysztof
2006-01-01
The most probable place generating tinnitus in auditory pathway are outer hair cells (OHC) inside cochlea. To asses their activity otoacoustic emission is used. The goal of the investigation was estimation the features of otoemission DPOAE in groups with tinnitus patients with cochlear hearing loss, estimation of diagnostic value of DPOAE parameters for analysis of function of the cochlea in investigated patients emphasizing DPOAE parameters most useful in localizing tinnitus generators and estimation of hypothetic influence of hyperacusis and misophony on parameters of DPOAE in tinnitus patients with cochlear hearing loss. The material of the study were 42 tinnitus patients with cochlear hearing loss. In the control group there were 21 patients without tinnitus with the same type of hearing loss. Then tinnitus patients were divided into three subgroups--with hyperacusis, misophony and without both of them, based on audiologic findings. after taking view on tinnitus and physical examination in all the patients pure tone and impedance audiometry, supratreshold tests, ABR and audiometric average and discomfort level were evaluated. Then otoemission DPOAE was measured in three procedures. First the amplitudes of two points per octave were assessed, in second--"fine structure" method-- 16-20 points per octave (f2/f1 = 1.2, L1 = L2 = 70 dB). Third procedure included recording of growth rate function in three series for input tones of value f2 = 2002, 4004, 6006 Hz (f2/f1= 1.22) and levels L1=L2, growing by degrees of 5dB in each series. DPOAE amplitudes in recording of 2 points per octave and fine structure method are very valuable parameters for estimation of cochlear function in tinnitus patients with cochlear hearing loss. Decreasing of DPOAE amplitudes in patients with cochlear hearing loss and tinnitus suggests significant role of OHC pathology, unbalanced by IHC injury in generation of tinnitus in patients with hearing loss of cochlear localization. DPOAE fine structure provides us the additional information about DPOAE amplitude recorded in two points per octave, spreading the amount of frequencies f2, where differences are noticed in comparison of two groups--tinnitus patients and control. Function growth rate cannot be the only parameter in estimation of DPOAE in tinnitus patients with cochlear hearing loss, also including subjects with hyperacusis and misophony. Hyperacusis has important influence on DPOAE amplitude, increases essentially amplitude of DPOAE in the examined group of tinnitus patients.
Kang, Robert; Nimmons, Grace Liu; Drennan, Ward; Longnion, Jeff; Ruffin, Chad; Nie, Kaibao; Won, Jong Ho; Worman, Tina; Yueh, Bevan; Rubinstein, Jay
2009-08-01
Assessment of cochlear implant outcomes centers around speech discrimination. Despite dramatic improvements in speech perception, music perception remains a challenge for most cochlear implant users. No standardized test exists to quantify music perception in a clinically practical manner. This study presents the University of Washington Clinical Assessment of Music Perception (CAMP) test as a reliable and valid music perception test for English-speaking, adult cochlear implant users. Forty-two cochlear implant subjects were recruited from the University of Washington Medical Center cochlear implant program and referred by two implant manufacturers. Ten normal-hearing volunteers were drawn from the University of Washington Medical Center and associated campuses. A computer-driven, self-administered test was developed to examine three specific aspects of music perception: pitch direction discrimination, melody recognition, and timbre recognition. The pitch subtest used an adaptive procedure to determine just-noticeable differences for complex tone pitch direction discrimination within the range of 1 to 12 semitones. The melody and timbre subtests assessed recognition of 12 commonly known melodies played with complex tones in an isochronous manner and eight musical instruments playing an identical five-note sequence, respectively. Testing was repeated for cochlear implant subjects to evaluate test-retest reliability. Normal-hearing volunteers were also tested to demonstrate differences in performance in the two populations. For cochlear implant subjects, pitch direction discrimination just-noticeable differences ranged from 1 to 8.0 semitones (Mean = 3.0, SD = 2.3). Melody and timbre recognition ranged from 0 to 94.4% correct (mean = 25.1, SD = 22.2) and 20.8 to 87.5% (mean = 45.3, SD = 16.2), respectively. Each subtest significantly correlated at least moderately with both Consonant-Nucleus-Consonant (CNC) word recognition scores and spondee recognition thresholds in steady state noise and two-talker babble. Intraclass coefficients demonstrating test-retest correlations for pitch, melody, and timbre were 0.85, 0.92, and 0.69, respectively. Normal-hearing volunteers had a mean pitch direction discrimination threshold of 1.0 semitone, the smallest interval tested, and mean melody and timbre recognition scores of 87.5 and 94.2%, respectively. The CAMP test discriminates a wide range of music perceptual ability in cochlear implant users. Moderate correlations were seen between music test results and both Consonant-Nucleus-Consonant word recognition scores and spondee recognition thresholds in background noise. Test-retest reliability was moderate to strong. The CAMP test provides a reliable and valid metric for a clinically practical, standardized evaluation of music perception in adult cochlear implant users.
Liu, Yi-Wen; Neely, Stephen T.
2013-01-01
This paper presents the results of simulating the acoustic suppression of distortion-product otoacoustic emissions (DPOAEs) from a computer model of cochlear mechanics. A tone suppressor was introduced, causing the DPOAE level to decrease, and the decrement was plotted against an increasing suppressor level. Suppression threshold was estimated from the resulting suppression growth functions (SGFs), and suppression tuning curves (STCs) were obtained by plotting the suppression threshold as a function of suppressor frequency. Results show that the slope of SGFs is generally higher for low-frequency suppressors than high-frequency suppressors, resembling those obtained from normal hearing human ears. By comparing responses of normal (100%) vs reduced (50%) outer-hair-cell sensitivities, the model predicts that the tip-to-tail difference of the STCs correlates well with that of intra-cochlear iso-displacement tuning curves. The correlation is poorer, however, between the sharpness of the STCs and that of the intra-cochlear tuning curves. These results agree qualitatively with what was recently reported from normal-hearing and hearing-impaired human subjects, and examination of intra-cochlear model responses can provide the needed insight regarding the interpretation of DPOAE STCs obtained in individual ears. PMID:23363112
Salicylate enables cochlear arachidonic-acid-sensitive NMDA receptor responses.
Ruel, Jérôme; Chabbert, Christian; Nouvian, Régis; Bendris, Rim; Eybalin, Michel; Leger, Claude Louis; Bourien, Jérôme; Mersel, Marcel; Puel, Jean-Luc
2008-07-16
Currently, many millions of people treated for various ailments receive high doses of salicylate. Consequently, understanding the mechanisms by which salicylate induces tinnitus is an important issue for the research community. Behavioral testing in rats have shown that tinnitus induced by salicylate or mefenamate (both cyclooxygenase blockers) are mediated by cochlear NMDA receptors. Here we report that the synapses between the sensory inner hair cells and the dendrites of the cochlear spiral ganglion neurons express NMDA receptors. Patch-clamp recordings and two-photon calcium imaging demonstrated that salicylate and arachidonate (a substrate of cyclooxygenase) enabled the calcium flux and the neural excitatory effects of NMDA on cochlear spiral ganglion neurons. Salicylate also increased the arachidonate content of the whole cochlea in vivo. Single-unit recordings of auditory nerve fibers in adult guinea pig confirmed the neural excitatory effect of salicylate and the blockade of this effect by NMDA antagonist. These results suggest that salicylate inhibits cochlear cyclooxygenase, which increased levels of arachidonate. The increased levels of arachidonate then act on NMDA receptors to enable NMDA responses to glutamate that inner hair cells spontaneously release. This new pharmacological profile of salicylate provides a molecular mechanism for the generation of tinnitus at the periphery of the auditory system.
Speaker recognition with temporal cues in acoustic and electric hearing
NASA Astrophysics Data System (ADS)
Vongphoe, Michael; Zeng, Fan-Gang
2005-08-01
Natural spoken language processing includes not only speech recognition but also identification of the speaker's gender, age, emotional, and social status. Our purpose in this study is to evaluate whether temporal cues are sufficient to support both speech and speaker recognition. Ten cochlear-implant and six normal-hearing subjects were presented with vowel tokens spoken by three men, three women, two boys, and two girls. In one condition, the subject was asked to recognize the vowel. In the other condition, the subject was asked to identify the speaker. Extensive training was provided for the speaker recognition task. Normal-hearing subjects achieved nearly perfect performance in both tasks. Cochlear-implant subjects achieved good performance in vowel recognition but poor performance in speaker recognition. The level of the cochlear implant performance was functionally equivalent to normal performance with eight spectral bands for vowel recognition but only to one band for speaker recognition. These results show a disassociation between speech and speaker recognition with primarily temporal cues, highlighting the limitation of current speech processing strategies in cochlear implants. Several methods, including explicit encoding of fundamental frequency and frequency modulation, are proposed to improve speaker recognition for current cochlear implant users.
Questioning cochlear amplification
NASA Astrophysics Data System (ADS)
van der Heijden, Marcel; Versteegh, Corstiaen P. C.
2015-12-01
Thirty years ago it was hypothesized that motile processes inject mechanical energy into cochlear traveling waves. This mechanical amplification, alternatively described as negative damping, is invoked to explain both the sensitivity and the nonlinear compression of cochlear responses. There is a recent trend to present cochlear amplification as an established fact, even though the evidence is at most circumstantial and several thorny problems have remained unresolved. We analyze several of these issues, and present new basilar membrane recordings that allowed us to quantify cochlear energy flow. Specifically, we address the following questions: (1) Does auditory sensitivity require narrowband amplification? (2) Has the "RC problem" (lowpass filtering of outer hair cell receptor potential) been resolved? (3) Can OHC motility improve auditory sensitivity? (4) Is there a net power gain between neighboring locations on the basilar membrane? The analyses indicate that mechanical amplification in the cochlea is neither necessary nor useful, and that realizing it by known forms of motility would reduce sensitivity rather than enhance it. Finally, our experimental data show that the peaking of the traveling wave is realized by focusing the acoustic energy rather than amplifying it. (Abbreviations. BM: basilar membrane; CF: characteristic frequency; IHC: inner hair cell; ME: middle ear; MT; mechanotransducer; OHC: outer hair cell; SPL: sound pressure level.)
Doppler optical coherence microscopy and tomography applied to inner ear mechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Page, Scott; Freeman, Dennis M.; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts
While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometermore » motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.« less
Wang, Sheng-zhi; Ibrahim, Leena A.; Kim, Young J.; Gibson, Daniel A.; Leung, Haiwen C.; Yuan, Wei; Zhang, Ke K.; Tao, Huizhong W.
2013-01-01
During the development of periphery auditory circuits, spiral ganglion neurons (SGNs) extend their neurites to innervate cochlear hair cells (HCs) with their soma aggregated into a cluster spatially segregated from the cochlear sensory epithelium. The molecular mechanisms underlying this spatial patterning remain unclear. In this study, in situ hybridization in the mouse cochlea suggests that Slit2 and its receptor, Robo1/2, exhibit apparently complementary expression patterns in the spiral ganglion and its nearby region, the spiral limbus. In Slit2 and Robo1/2 mutants, the spatial restriction of SGNs was disrupted. Mispositioned SGNs were found to scatter in the space between the cochlear epithelium and the main body of spiral ganglion, and the neurites of mispositioned SGNs were misrouted and failed to innervate HCs. Furthermore, in Robo1/2 mutants, SGNs were displaced toward the cochlear epithelium as an entirety. Examination of different embryonic stages in the mutants revealed that the mispositioning of SGNs was due to a progressive displacement to ectopic locations after their initial normal settlement at an earlier stage. Our results suggest that Slit/Robo signaling imposes a restriction force on SGNs to ensure their precise positioning for correct SGN-HC innervations. PMID:23884932
Coupling Active Hair Bundle Mechanics, Fast Adaptation, and Somatic Motility in a Cochlear Model
Meaud, Julien; Grosh, Karl
2011-01-01
One of the central questions in the biophysics of the mammalian cochlea is determining the contributions of the two active processes, prestin-based somatic motility and hair bundle (HB) motility, to cochlear amplification. HB force generation is linked to fast adaptation of the transduction current via a calcium-dependent process and somatic force generation is driven by the depolarization caused by the transduction current. In this article, we construct a global mechanical-electrical-acoustical mathematical model of the cochlea based on a three-dimensional fluid representation. The global cochlear model is coupled to linearizations of nonlinear somatic motility and HB activity as well as to the micromechanics of the passive structural and electrical elements of the cochlea. We find that the active HB force alone is not sufficient to power high frequency cochlear amplification. However, somatic motility can overcome resistor-capacitor filtering by the basolateral membrane and deliver sufficient mechanical energy for amplification at basal locations. The results suggest a new theory for high frequency active cochlear mechanics, in which fast adaptation controls the transduction channel sensitivity and thereby the magnitude of the energy delivered by somatic motility. PMID:21641302
Coupling active hair bundle mechanics, fast adaptation, and somatic motility in a cochlear model.
Meaud, Julien; Grosh, Karl
2011-06-08
One of the central questions in the biophysics of the mammalian cochlea is determining the contributions of the two active processes, prestin-based somatic motility and hair bundle (HB) motility, to cochlear amplification. HB force generation is linked to fast adaptation of the transduction current via a calcium-dependent process and somatic force generation is driven by the depolarization caused by the transduction current. In this article, we construct a global mechanical-electrical-acoustical mathematical model of the cochlea based on a three-dimensional fluid representation. The global cochlear model is coupled to linearizations of nonlinear somatic motility and HB activity as well as to the micromechanics of the passive structural and electrical elements of the cochlea. We find that the active HB force alone is not sufficient to power high frequency cochlear amplification. However, somatic motility can overcome resistor-capacitor filtering by the basolateral membrane and deliver sufficient mechanical energy for amplification at basal locations. The results suggest a new theory for high frequency active cochlear mechanics, in which fast adaptation controls the transduction channel sensitivity and thereby the magnitude of the energy delivered by somatic motility. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Using Flanagan's phase vocoder to improve cochlear implant performance
NASA Astrophysics Data System (ADS)
Zeng, Fan-Gang
2004-10-01
The cochlear implant has restored partial hearing to more than 100
De Raeve, Leo; Wouters, Annelies
2013-03-01
Belgium, and especially the northern region called Flanders, has been a center of expertise in cochlear implants and early hearing screening for many years. Some of their surgeons and engineers were pioneers in the development of cochlear implants and in 1998 Flanders was the first region in Europe to implement a universal hearing screening program for all neonates. The Belgian National Institute for Health and Disability Insurance has reimbursed cochlear implants in children and adults since 1994 and bilateral implantation in children under the age of 12 years since February 2010. These deaf children, screened and implanted early, achieve higher auditory, speech and language outcomes and increasing numbers are going to regular schools using fewer interpreters. In 2010, 93% of severe-to-profound deaf preschool children in Flanders had received cochlear implants and 25% had bilateral implants. Although on average twice as many adults as children are implanted a year in Belgium, we have less research data available from this adult population. Also very little is published about the growth curves and minimal rehabilitation requirements (intensity, duration etc.) after implantation for both children and adults. So, there still remain many challenges for the future.
Supporting skill acquisition in cochlear implant surgery through virtual reality simulation.
Copson, Bridget; Wijewickrema, Sudanthi; Zhou, Yun; Piromchai, Patorn; Briggs, Robert; Bailey, James; Kennedy, Gregor; O'Leary, Stephen
2017-03-01
To evaluate the effectiveness of a virtual reality (VR) temporal bone simulator in training cochlear implant surgery. We compared the performance of 12 otolaryngology registrars conducting simulated cochlear implant surgery before (pre-test) and after (post-tests) receiving training on a VR temporal bone surgery simulator with automated performance feedback. The post-test tasks were two temporal bones, one that was a mirror image of the temporal bone used as a pre-test and the other, a novel temporal bone. Participant performances were assessed by an otologist with a validated cochlear implant competency assessment tool. Structural damage was derived from an automatically generated simulator metric and compared between time points. Wilcoxon signed-rank test showed that there was a significant improvement with a large effect size in the total performance scores between the pre-test (PT) and both the first and second post-tests (PT1, PT2) (PT-PT1: P = 0.007, r = 0.78, PT-PT2: P = 0.005, r = 0.82). The results of the study indicate that VR simulation with automated guidance can effectively be used to train surgeons in training complex temporal bone surgeries such as cochlear implantation.
Mandarin Chinese Tone Identification in Cochlear Implants: Predictions from Acoustic Models
Morton, Kenneth D.; Torrione, Peter A.; Throckmorton, Chandra S.; Collins, Leslie M.
2015-01-01
It has been established that current cochlear implants do not supply adequate spectral information for perception of tonal languages. Comprehension of a tonal language, such as Mandarin Chinese, requires recognition of lexical tones. New strategies of cochlear stimulation such as variable stimulation rate and current steering may provide the means of delivering more spectral information and thus may provide the auditory fine structure required for tone recognition. Several cochlear implant signal processing strategies are examined in this study, the continuous interleaved sampling (CIS) algorithm, the frequency amplitude modulation encoding (FAME) algorithm, and the multiple carrier frequency algorithm (MCFA). These strategies provide different types and amounts of spectral information. Pattern recognition techniques can be applied to data from Mandarin Chinese tone recognition tasks using acoustic models as a means of testing the abilities of these algorithms to transmit the changes in fundamental frequency indicative of the four lexical tones. The ability of processed Mandarin Chinese tones to be correctly classified may predict trends in the effectiveness of different signal processing algorithms in cochlear implants. The proposed techniques can predict trends in performance of the signal processing techniques in quiet conditions but fail to do so in noise. PMID:18706497
Evidence-based guidelines for recommending cochlear implantation for postlingually deafened adults.
Leigh, Jaime R; Moran, Michelle; Hollow, Rodney; Dowell, Richard C
2016-01-01
Adult selection criteria for cochlear implantation have been developed based on analysis of the post-operative performance of a large group of postlingually deafened adults. Original criteria published in 2004 were reviewed and amended to reflect outcomes currently being achieved by implant recipients. Retrospective review of 12-month post-operative speech perception performance of adults implanted at the Eye and Ear Hospital, Melbourne, Australia. A total of 382 postlingually deafened adults, using a Freedom, Nucleus 5, or CI422 Slim Straight cochlear implant were used to create a comparative set of data. Revised guidelines suggest that adults with postlingual hearing loss can now be considered cochlear implant candidates if they obtain scores of up to 55% for open-set phonemes in quiet in the ear to be implanted. Functional benefit may vary depending on the recipients' contralateral hearing. This study supports the provision of cochlear implants to candidates with significant residual hearing when at least one ear meets the criterion outlined above. Patient-specific counseling is required to ensure the potential to benefit predicted by the current model is acceptable to the individual patient and their family. Counseling regarding functional benefit must take into consideration hearing in the contralateral ear.
Dislocation of cochlear implant magnet as a complication following MRI.
Murtojärvi, Sarita; Salonen, Jaakko
According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.
Bilateral and unilateral cochlear implant users compared on speech perception in noise.
Dunn, Camille C; Noble, William; Tyler, Richard S; Kordus, Monika; Gantz, Bruce J; Ji, Haihong
2010-04-01
Compare speech performance in noise with matched bilateral cochlear implant (CICI) and unilateral cochlear implant (CI only) users. Thirty CICI and 30 CI-only subjects were tested on a battery of speech perception tests in noise that use an eight-loudspeaker array. On average, CICI subject's performance with speech in noise was significantly better than the CI-only subjects. The CICI group showed significantly better performance on speech perception in noise compared with the CI-only subjects, supporting the hypothesis that CICI is more beneficial than CI only.
Consequences of Location-Dependent Organ of Corti Micro-Mechanics
Liu, Yanju; Gracewski, Sheryl M.; Nam, Jong-Hoon
2015-01-01
The cochlea performs frequency analysis and amplification of sounds. The graded stiffness of the basilar membrane along the cochlear length underlies the frequency-location relationship of the mammalian cochlea. The somatic motility of outer hair cell is central for cochlear amplification. Despite two to three orders of magnitude change in the basilar membrane stiffness, the force capacity of the outer hair cell’s somatic motility, is nearly invariant over the cochlear length. It is puzzling how actuators with a constant force capacity can operate under such a wide stiffness range. We hypothesize that the organ of Corti sets the mechanical conditions so that the outer hair cell’s somatic motility effectively interacts with the media of traveling waves—the basilar membrane and the tectorial membrane. To test this hypothesis, a computational model of the gerbil cochlea was developed that incorporates organ of Corti structural mechanics, cochlear fluid dynamics, and hair cell electro-physiology. The model simulations showed that the micro-mechanical responses of the organ of Corti are different along the cochlear length. For example, the top surface of the organ of Corti vibrated more than the bottom surface at the basal (high frequency) location, but the amplitude ratio was reversed at the apical (low frequency) location. Unlike the basilar membrane stiffness varying by a factor of 1700 along the cochlear length, the stiffness of the organ of Corti complex felt by the outer hair cell remained between 1.5 and 0.4 times the outer hair cell stiffness. The Y-shaped structure in the organ of Corti formed by outer hair cell, Deiters cell and its phalange was the primary determinant of the elastic reactance imposed on the outer hair cells. The stiffness and geometry of the Deiters cell and its phalange affected cochlear amplification differently depending on the location. PMID:26317521
Ortmann, Magdalene; Zwitserlood, Pienie; Knief, Arne; Baare, Johanna; Brinkheetker, Stephanie; am Zehnhoff-Dinnesen, Antoinette; Dobel, Christian
2017-01-01
Cochlear implants provide individuals who are deaf with access to speech. Although substantial advancements have been made by novel technologies, there still is high variability in language development during childhood, depending on adaptation and neural plasticity. These factors have often been investigated in the auditory domain, with the mismatch negativity as an index for sensory and phonological processing. Several studies have demonstrated that the MMN is an electrophysiological correlate for hearing improvement with cochlear implants. In this study, two groups of cochlear implant users, both with very good basic hearing abilities but with non-overlapping speech performance (very good or very poor speech performance), were matched according to device experience and age at implantation. We tested the perception of phonemes in the context of specific other phonemes from which they were very hard to discriminate (e.g., the vowels in /bu/ vs. /bo/). The most difficult pair was individually determined for each participant. Using behavioral measures, both cochlear implants groups performed worse than matched controls, and the good performers performed better than the poor performers. Cochlear implant groups and controls did not differ during time intervals typically used for the mismatch negativity, but earlier: source analyses revealed increased activity in the region of the right supramarginal gyrus (220–260 ms) in good performers. Poor performers showed increased activity in the left occipital cortex (220–290 ms), which may be an index for cross-modal perception. The time course and the neural generators differ from data from our earlier studies, in which the same phonemes were assessed in an easy-to-discriminate context. The results demonstrate that the groups used different language processing strategies, depending on the success of language development and the particular language context. Overall, our data emphasize the role of neural plasticity and use of adaptive strategies for successful language development with cochlear implants. PMID:28056017
Effects of sustained release dexamethasone hydrogels in hearing preservation cochlear implantation.
Honeder, Clemens; Zhu, Chengjing; Schöpper, Hanna; Gausterer, Julia Clara; Walter, Manuel; Landegger, Lukas David; Saidov, Nodir; Riss, Dominik; Plasenzotti, Roberto; Gabor, Franz; Arnoldner, Christoph
2016-11-01
It has been shown that glucocorticoids reduce the hearing threshold shifts associated with cochlear implantation. Previous studies evaluated the administration of glucocorticoids immediately before surgery or the repeated pre- or perioperative systemic application of glucocorticoids. The aim of this study was to evaluate the effects of a sustained release dexamethasone hydrogel in hearing preservation cochlear implantation. To address this issue, a guinea pig model of cochlear implantation was used. 30 normal hearing pigmented guinea pigs were randomized into a group receiving a single dose of a dexamethasone/poloxamer407 hydrogel one day prior to surgery, a second group receiving the hydrogel seven days prior to surgery and a control group. A silicone cochlear implant electrode designed for the use in guinea pigs was inserted to a depth of 5 mm through a cochleostomy. Compound action potentials of the auditory nerve (frequency range 0.5-32 kHz) were measured preoperatively, directly postoperatively and on postoperative days 3, 7, 14, 21 and 28. Following the last audiometry, temporal bones were harvested and histologically evaluated. Dexamethasone hydrogel application one day prior to surgery resulted in significantly reduced hearing threshold shifts at low, middle and high frequencies measured at postoperative day 28 (p < 0.05). Application of the hydrogel seven days prior to surgery did not show such an effect. Dexamethasone application one day prior to surgery resulted in increased outer hair cell counts in the cochlear apex and in reduced spiral ganglion cell counts in the basal and middle turn of the cochlea, a finding that was associated with a higher rate of electrode translocation in this group. In this study, we were able to demonstrate functional benefits of a single preoperative intratympanic application of a sustained release dexamethasone hydrogel in a guinea pig model of cochlear implantation. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
American parent perspectives on quality of life in pediatric cochlear implant recipients.
Kumar, Roshini; Warner-Czyz, Andrea; Silver, Cheryl H; Loy, Betty; Tobey, Emily
2015-01-01
Cochlear implantation influences not only communication but also psychosocial outcomes in children with severe to profound hearing loss. Focusing on issues specific to cochlear implantation (e.g., self-reliance, social relations, education, effects of implantation, and supporting the child) may provide a more accurate and relative view of functional status of pediatric cochlear implant (CI) recipients. The present study analyzes parental perspectives of CI-specific health-related quality of life (HRQoL) in children with CIs to determine (a) if parents differentially rate their child's quality of life according to psychosocial domain (e.g., communication, self-reliance, education); (b) if associations exist between quality of life domains specific to cochlear implantation in pediatric implant recipients; and (c) if demographic variables (i.e., chronologic age, age at cochlear implantation, duration of device experience) mediate parent ratings of quality of life in pediatric CI recipients. Parents of 33 children with CIs (mean age, 9.85 years; mean age of CI activation, 2.47 years; mean device experience, 7.47 years) completed a validated condition-specific questionnaire, Children With Cochlear Implants: Parental Perspectives. Parents positively rated most HRQoL domains, although education and effects of implantation received significantly less positive ratings (p < 0.01). Three domains (communication, self-reliance, and well-being) significantly correlated with at least 5 other domains, suggesting that positivity in one domain co-occurs with positivity in other domains. Demographic variables (chronologic age, CI activation age, and duration of CI use) did not correlate significantly with psychosocial outcomes; rather, parents reported positive HRQoL and successful functional use of CI across demographic variables. Parents of children and adolescents with CIs rate overall HRQoL positively across psychosocial domains. Significantly less positive ratings of education and effects of implantation may result from limited access to CI-related accommodations and varying parent expectations, warranting further exploration to maximize psychosocial and performance outcomes in pediatric CI users.
A cochlear implant fabricated using a bulk silicon-surface micromachining process
NASA Astrophysics Data System (ADS)
Bell, Tracy Elizabeth
1999-11-01
This dissertation presents the design and fabrication of two generations of a silicon microelectrode array for use in a cochlear implant. A cochlear implant is a device that is inserted into the inner ear and uses electrical stimulation to provide sound sensations to the profoundly deaf. The first-generation silicon cochlear implant is a passive device fabricated using silicon microprobe technology developed at the University of Michigan. It contains twenty-two iridium oxide (IrO) stimulating sites that are 250 mum in diameter and spaced at 750 mum intervals. In-vivo recordings were made in guinea pig auditory cortex in response to electrical stimulation with this device, verifying its ability to electrically evoke an auditory response. Auditory thresholds as low as 78 muA were recorded. The second-generation implant is a thirty-two site, four-channel device with on-chip CMOS site-selection circuitry and integrated position sensing. It was fabricated using a novel bulk silicon surface micromachining process which was developed as a part of this dissertation work. While the use of semiconductor technology offers many advantages in fabricating cochlear implants over the methods currently used, it was felt that even further advantages could be gained by developing a new micromachining process which would allow circuitry to be distributed along the full length of the cochlear implant substrate. The new process uses electropolishing of an n+ bulk silicon sacrificial layer to undercut and release n- epitaxial silicon structures from the wafer. An extremely abrupt etch-stop between the n+ and n- silicon is obtained, with no electropolishing taking place in the n-type silicon that is doped lower than 1 x 1017 cm-3 in concentration. Lateral electropolishing rates of up to 50 mum/min were measured using this technique, allowing one millimeter-wide structures to be fully undercut in as little as 10 minutes. The new micromachining process was integrated with a standard p-well CMOS integrated circuit process to fabricate the second-generation active silicon cochlear implants.
Design and Evaluation of a Personal Digital Assistant-based Research Platform for Cochlear Implants
Ali, Hussnain; Lobo, Arthur P.; Loizou, Philipos C.
2014-01-01
This paper discusses the design, development, features, and clinical evaluation of a personal digital assistant (PDA)-based platform for cochlear implant research. This highly versatile and portable research platform allows researchers to design and perform complex experiments with cochlear implants manufactured by Cochlear Corporation with great ease and flexibility. The research platform includes a portable processor for implementing and evaluating novel speech processing algorithms, a stimulator unit which can be used for electrical stimulation and neurophysio-logic studies with animals, and a recording unit for collecting electroencephalogram/evoked potentials from human subjects. The design of the platform for real time and offline stimulation modes is discussed for electric-only and electric plus acoustic stimulation followed by results from an acute study with implant users for speech intelligibility in quiet and noisy conditions. The results are comparable with users’ clinical processor and very promising for undertaking chronic studies. PMID:23674422
Patients reported outcome post-cochlear implantation: how severe is their dizziness?
Zawawi, Faisal; Alobaid, Faisal; Leroux, Tony; Zeitouni, Anthony G
2014-01-01
The reported prevalence of vestibular dysfunction after cochlear implantation (CI) is varies between different scientific papers. The aim of this study is to determine the reported post-implantation outcome in terms of dizziness, and to measure its impact on quality of life using the Dizziness handicap inventory (DHI). This was a prospective questionnaire based study of postoperative cochlear implant patients. The questionnaire assessed the type and onset of dizziness in addition to the DHI. 122 patients were recruited in this study, which is the largest sample size in the literature reported so far. Dizziness was evident in 45.9% of the population post-CI and in 27% pre-CI. The commonest subtype of the dizziness was unsteadiness followed by lightheadedness. The dizziness was mild in most of the patients. Although mild, dizziness is a common complaint post-cochlear implantation. An understanding of symptoms helps counsel patients preoperatively.
Ultrasound Produces Extensive Brain Activation via a Cochlear Pathway.
Guo, Hongsun; Hamilton, Mark; Offutt, Sarah J; Gloeckner, Cory D; Li, Tianqi; Kim, Yohan; Legon, Wynn; Alford, Jamu K; Lim, Hubert H
2018-06-06
Ultrasound (US) can noninvasively activate intact brain circuits, making it a promising neuromodulation technique. However, little is known about the underlying mechanism. Here, we apply transcranial US and perform brain mapping studies in guinea pigs using extracellular electrophysiology. We find that US elicits extensive activation across cortical and subcortical brain regions. However, transection of the auditory nerves or removal of cochlear fluids eliminates the US-induced activity, revealing an indirect auditory mechanism for US neural activation. Our findings indicate that US activates the ascending auditory system through a cochlear pathway, which can activate other non-auditory regions through cross-modal projections. This cochlear pathway mechanism challenges the idea that US can directly activate neurons in the intact brain, suggesting that future US stimulation studies will need to control for this effect to reach reliable conclusions. Copyright © 2018 Elsevier Inc. All rights reserved.
A cochlear-bone wave can yield a hearing sensation as well as otoacoustic emission
Tchumatchenko, Tatjana; Reichenbach, Tobias
2014-01-01
A hearing sensation arises when the elastic basilar membrane inside the cochlea vibrates. The basilar membrane is typically set into motion through airborne sound that displaces the middle ear and induces a pressure difference across the membrane. A second, alternative pathway exists, however: stimulation of the cochlear bone vibrates the basilar membrane as well. This pathway, referred to as bone conduction, is increasingly used in headphones that bypass the ear canal and the middle ear. Furthermore, otoacoustic emissions, sounds generated inside the cochlea and emitted therefrom, may not involve the usual wave on the basilar membrane, suggesting that additional cochlear structures are involved in their propagation. Here we describe a novel propagation mode within the cochlea that emerges through deformation of the cochlear bone. Through a mathematical and computational approach we demonstrate that this propagation mode can explain bone conduction as well as numerous properties of otoacoustic emissions. PMID:24954736
King, EB; Hartsock, JJ; O'Leary, SJ; Salt, AN
2013-01-01
Locally-applied drugs can protect residual hearing following cochlear implantation. The influence of cochlear implantation on drug levels in scala tympani (ST) after round window application was investigated in guinea pigs using the marker trimethylphenlyammonium (TMPA) measured in real-time with TMPA-selective microelectrodes. TMPA concentration in the upper basal turn of ST rapidly increased during implantation and then declined due to cerebrospinal fluid entering ST at the cochlear aqueduct and exiting at the cochleostomy. The TMPA increase was found to be caused by the cochleostomy drilling, if the burr tip partially entered ST. TMPA distribution in the second turn was less affected by implantation procedures. These findings show that basal turn drug levels may be changed during implantation and the changes may need to be considered in the interpretation of therapeutic effects of drugs in conjunction with implantation. PMID:24008355
Cochlear pathology in chronic suppurative otitis media.
Walby, A P; Barrera, A; Schuknecht, H F
1983-01-01
Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.
Richardson, G P; Forge, A; Kros, C J; Marcotti, W; Becker, D; Williams, D S; Thorpe, J; Fleming, J; Brown, S D; Steel, K P
1999-11-28
Myosin VIIA is expressed by sensory hair cells in the inner ear and proximal tubule cells in the kidney, the two primary targets of aminoglycoside antibiotics. Using cochlear cultures prepared from early postnatal Myo7a6J mice with a missense mutation in the head region of the myosin VIIA molecule we show that this myosin is required for aminoglycoside accumulation in cochlear hair cells. Hair cells in homozygous mutant Myo7a6J cochlear cultures have disorganized hair bundles, but are otherwise morphologically normal and transduce. However, and in contrast to hair cells from heterozygous Myo7a6J cultures, the homozygous Myo7a6J hair cells do not accumulate [3H]gentamicin and do not exhibit an ototoxic response on exposure to aminoglycoside. Possible roles for myosin VIIA in the process of aminoglycoside accumulation are discussed.
Vestibulo-ocular and vestibulospinal function before and after cochlear implant surgery
NASA Technical Reports Server (NTRS)
Black, F. O.; Lilly, D. J.; Peterka, R. J.; Fowler, L. P.; Simmons, F. B.
1987-01-01
Vestibular function in cochlear implant candidates varies from normal to total absence of function. In patients with intact vestibular function preoperatively, invasion of the otic capsule places residual vestibular function at risk. Speech-processing strategies that result in large amplitude electrical transients or strategies that employ high amplitude broad frequency carrier signals have the potential for disrupting vestibular function. Five patients were tested with and without electrical stimulation via cochlear electrodes. Two patients experienced subjective vestibular effects that were quickly resolved. No long-term vestibular effects were noted for the two types of second generation cochlear implants evaluated. Histopathological findings from another patient, who had electrically generated vestibular reflex responses to intramodiolar electrodes, indicated that responses elicited were a function of several variables including electrode location, stimulus intensity, stimulus amplitude, and stimulus frequency. Differential auditory, vestibulocolic, and vestibulospinal reflexes were demonstrated from the same electrode as a function of stimulus amplitude, frequency, and duration.
Giesemann, Anja M; Raab, Peter; Lyutenski, Stefan; Dettmer, Sabine; Bültmann, Eva; Frömke, Cornelia; Lenarz, Thomas; Lanfermann, Heinrich; Goetz, Friedrich
2014-03-01
Magnetic resonance imaging of the temporal bone has an important role in decision making with regard to cochlea implantation, especially in children with cochlear nerve deficiency. The purpose of this study was to evaluate the usefulness of the combination of an advanced high-resolution T2-weighted sequence with a surface coil in a 3-Tesla magnetic resonance imaging scanner in cases of suspected cochlear nerve aplasia. Prospective study. Seven patients with cochlear nerve hypoplasia or aplasia were prospectively examined using a high-resolution three-dimensional variable flip-angle turbo spin-echo sequence using a surface coil, and the images were compared with the same sequence in standard resolution using a standard head coil. Three neuroradiologists evaluated the magnetic resonance images independently, rating the visibility of the nerves in diagnosing hypoplasia or aplasia. Eight ears in seven patients with hypoplasia or aplasia of the cochlear nerve were examined. The average age was 2.7 years (range, 9 months-5 years). Seven ears had accompanying malformations. The inter-rater reliability in diagnosing hypoplasia or aplasia was greater using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence (fixed-marginal kappa: 0.64) than with the same sequence in lower resolution (fixed-marginal kappa: 0.06). Examining cases of suspected cochlear nerve aplasia using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence in combination with a surface coil shows significant improvement over standard methods. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Huang, B Y; Roche, J P; Buchman, C A; Castillo, M
2010-11-01
Cranial abnormalities, including CND, are common in children with ANSD. The purpose of this study was to assess whether CND is associated with brain or inner ear abnormalities in a cohort of children with ANSD. Two neuroradiologists retrospectively reviewed cranial MR imaging examinations in 103 children with ANSD. Brain, cochlear nerve, and temporal bone abnormalities were described and tabulated. Findings were stratified on the basis of the presence and laterality of CND, and differences in the presence of associated inner ear or intracranial abnormalities were assessed by using 2-tailed Fisher exact tests. CND was identified in 33.0% of children and 26.9% of ears with ANSD. Significantly more patients with bilateral CND had intracranial abnormalities than those with unilateral CND (60.0% versus 15.8%; P = .012). Forty percent of patients with bilateral CND, 0% of patients with unilateral CND, and 10.1% of those without CND demonstrated hindbrain malformations. Patients with bilateral CND were more likely to demonstrate hindbrain malformations than patients with normal nerves (P = .01) or unilateral CND (P = .004). Labyrinthine abnormalities were significantly more common in patients with bilateral CND than in those without CND (P ≤ .001). Cochlear anomalies were more common in patients with bilateral versus unilateral CND (P = .01). IAC and cochlear aperture stenosis were more common in those with unilateral and bilateral CND than those without CND (both P < .001). Cochlear and hindbrain abnormalities are significantly more common among patients with ANSD with bilateral CND compared with those with at least 1 intact cochlear nerve.
Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W
2015-05-20
During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.
Trudel, Mathieu; Côté, Mathieu; Philippon, Daniel; Simonyan, David; Villemure-Poliquin, Noémie; Bussières, Richard
2018-07-01
To compare scala vestibuli versus scala tympani cochlear implantation in terms of postoperative auditory performances and programming parameters in patients with severe scala tympani ossification. Retrospective case-control study. Tertiary referral center. One hundred three pediatric and adult patients who underwent cochlear implant surgery between 2000 and 2016. Three groups were formed: a scala vestibuli group, a scala tympani with ossification group, and a scala tympani without ossification group. Patients were matched based on their age, sex, duration of deafness, and side of implantation (ratio of 1:2:2). Postoperative evaluation of auditory performances and programming parameters following intensive functional rehabilitation program completion. Multimedia adaptive test (MAT), hearing in noise test (HINT SNR +10 dB, HINT SNR +5 dB, and HINT SNR +0 dB), impedances, neural response telemetry thresholds (NRT), neural response imaging thresholds (NRI), comfortable levels (C-levels), and threshold levels (T-levels) were compared between groups. Twenty-one patients underwent scala vestibuli cochlear implantation: 19 adults and two children. Auditory performances were similar between groups, although sentence recognition in a noisy environment was slightly higher in the scala vestibuli group. Impedance values were also higher in the scala vestibuli group, but all other programming parameters were similar between groups. We present the largest series of patients with scala vestibuli cochlear implantation. This approach provides at least comparable auditory performances without having any deleterious effects on programming parameters. This viable and useful insertion route might be the primary surgical alternative when facing partial cochlear ossification.
Xiao, Hanqiong; Li, Wei; Ma, Ruixia; Gong, Zhengpeng; Shi, Haibo; Li, Huawei; Chen, Bing; Jiang, Ye; Dai, Chunfu
2015-06-01
To describe tne regional different factors which impact on early cochlear implantation in prelingual deaf children between eastern and western regions of China. The charts of 113 children who received the cochlear implantation after 24 months old were reviewed and analyzed. Forty-five of them came from the eastern region (Jiangsu, Zhejiang or Shanghai) while 68 of them came from the western region (Ningxia or Guizhou). Parental interviews were conducted to collect information regarding the factors that impact on early cochlear implantation. Result:Based on the univariate logistic regression analysis, the odds ratio (OR) value of universal newborn hearing screening (UNHS) was 5. 481, which indicated the correlation of UNHS with early cochlear implantation is significant. There was statistical difference between the 2 groups (P<0. 01). For the financial burden, the OR value was 3. 521(strong correlation) and there was statistical difference between the 2 groups (P<0. 01). For the communication barriers and community location, the OR value was 0. 566 and 1. 128 respectively, and there was no statistical difference between the 2 groups (P>0. 05). The multivariate analysis indicated that the UNHS and financial burden are statistically different between the eastern and western regions (P=0. 00 and 0. 040 respectively). The UNHS and financial burden are statistically different between the eastern reinforced in the western region. In addition, the government and society should provide powerful policy and more financial support in the western region of China. The innovation of management system is also helpful to the early cochlear implantation.
Moore, Brian C J
2003-03-01
To review how the properties of sounds are "coded" in the normal auditory system and to discuss the extent to which cochlear implants can and do represent these codes. Data are taken from published studies of the response of the cochlea and auditory nerve to simple and complex stimuli, in both the normal and the electrically stimulated ear. REVIEW CONTENT: The review describes: 1) the coding in the normal auditory system of overall level (which partly determines perceived loudness), spectral shape (which partly determines perceived timbre and the identity of speech sounds), periodicity (which partly determines pitch), and sound location; 2) the role of the active mechanism in the cochlea, and particularly the fast-acting compression associated with that mechanism; 3) the neural response patterns evoked by cochlear implants; and 4) how the response patterns evoked by implants differ from those observed in the normal auditory system in response to sound. A series of specific issues is then discussed, including: 1) how to compensate for the loss of cochlear compression; 2) the effective number of independent channels in a normal ear and in cochlear implantees; 3) the importance of independence of responses across neurons; 4) the stochastic nature of normal neural responses; 5) the possible role of across-channel coincidence detection; and 6) potential benefits of binaural implantation. Current cochlear implants do not adequately reproduce several aspects of the neural coding of sound in the normal auditory system. Improved electrode arrays and coding systems may lead to improved coding and, it is hoped, to better performance.
Zong, Liang; Chen, Jin; Zhu, Yan; Zhao, Hong-Bo
2017-07-22
Mutations of Connexin 26 (Cx26, GJB2), which is a predominant gap junction isoform in the cochlea, can induce high incidence of nonsyndromic hearing loss. We previously found that targeted-deletion of Cx26 in supporting Deiters cells and outer pillar cells in the cochlea can influence outer hair cell (OHC) electromotility and reduce active cochlear amplification leading to hearing loss, even though there are no gap junction connexin expressions in the auditory sensory hair cells. Here, we further report that hearing loss and the reduction of active amplification in the Cx26 targeted-deletion mice are progressive and different at high and low frequency regions, first occurring in the high frequency region and then progressively extending to the middle and low frequency regions with mouse age increased. The speed of hearing loss extending was fast in the basal high frequency region and slow in the apical low frequency region, showing a logarithmic function with mouse age. Before postnatal day 25, there were no significant hearing loss and the reduction of active cochlear amplification in the low frequency region. Hearing loss and the reduction of active cochlear amplification also had frequency difference, severe and large in the high frequency regions. These new data indicate that the effect of gap junction on active cochlear amplification is progressive, but, consistent with our previous report, exists in both high and low frequency regions in adulthood. These new data also suggest that cochlear gap junctions may have an important role in age-related hearing loss. Copyright © 2017 Elsevier Inc. All rights reserved.
Bruijnzeel, Hanneke; Bezdjian, Aren; Lesinski-Schiedat, Anke; Illg, Angelika; Tzifa, Konstance; Monteiro, Luisa; Volpe, Antonio Della; Grolman, Wilko; Topsakal, Vedat
2017-11-01
International guidelines indicate that children with profound hearing loss should receive a cochlear implant (CI) soon after diagnosis in order to optimize speech and language rehabilitation. Although prompt rehabilitation is encouraged by current guidelines, delays in cochlear implantation are still present. This study investigated whether European countries establish timely pediatric CI care based on epidemiological, commercial, and clinical data. An estimation of the number of pediatric CI candidates in European countries was performed and compared to epidemiological (Euro-CIU), commercial (Cochlear ® ), and clinical (institutional) age-at-implantation data. The ages at implantation of pediatric patients in eight countries (the Netherlands, Belgium, Germany, the United Kingdom, France, Turkey, Portugal, and Italy) between 2005 and 2015 were evaluated. From 2010 onwards, over 30% of the pediatric CI candidates were implanted before 24 months of age. Northern European institutions implanted children on average around 12 months of age, whereas southern European institutions implanted children after 18 months of age. The Netherlands and Germany implanted earliest (between 6 and 11 months). Implemented newborn hearing screening programs and reimbursement rates of CIs vary greatly within Europe due to local, social, financial, and political differences. However, internationally accepted recommendations are applicable to this heterogeneous European CI practice. Although consensus on early pediatric cochlear implantation exists, this study identified marked delays in European care. Regardless of the great heterogeneity in European practice, reasons for latency should be identified on a national level and possibilities to prevent avoidable future implantation delays should be explored to provide national recommendations.
Athalye, Sheetal; Archbold, Sue; Mulla, Imran; Lutman, Mark; Nikolopoulous, Thomas
2015-09-01
The objective of this survey was to explore the perceptions of implant users/carers and professionals across the UK about current and future cochlear implant service delivery and the challenges. Data were collected via an online questionnaire consisting of totally 22 questions. The questionnaire contained both open- and close-ended questions. Totally, seven hundred and forty-eight responses were received. In spite of the wide range of respondents, there was a broad consensus of opinion across groups. The majority of participants were satisfied with the service they currently receive, but wanted some changes. They reported their current experience of implant services to be mainly driven by decisions made by the implant team. For the future, they preferred the service to be mainly driven by decisions made jointly by the team and the user and/or parent/carer. The majority of participants wanted the cochlear implant services to be integrated into local audiology and other services such as education. Restrictions on number of candidates funded and political decisions and issues were seen as major challenges. Qualitative analysis of the open-ended responses supported the questionnaire responses. This research highlighted the benefits and limitations of the current cochlear implant service delivery as well as the potential implications for the long term. While respondents were generally happy with the current cochlear implant service provision, they expressed some concerns about the long-term sustainability and management, wanting integration into the local services, and more involvement of parents and users in decisions.
Vibration of the organ of Corti within the cochlear apex in mice
Gao, Simon S.; Wang, Rosalie; Raphael, Patrick D.; Moayedi, Yalda; Groves, Andrew K.; Zuo, Jian; Applegate, Brian E.
2014-01-01
The tonotopic map of the mammalian cochlea is commonly thought to be determined by the passive mechanical properties of the basilar membrane. The other tissues and cells that make up the organ of Corti also have passive mechanical properties; however, their roles are less well understood. In addition, active forces produced by outer hair cells (OHCs) enhance the vibration of the basilar membrane, termed cochlear amplification. Here, we studied how these biomechanical components interact using optical coherence tomography, which permits vibratory measurements within tissue. We measured not only classical basilar membrane tuning curves, but also vibratory responses from the rest of the organ of Corti within the mouse cochlear apex in vivo. As expected, basilar membrane tuning was sharp in live mice and broad in dead mice. Interestingly, the vibratory response of the region lateral to the OHCs, the “lateral compartment,” demonstrated frequency-dependent phase differences relative to the basilar membrane. This was sharply tuned in both live and dead mice. We then measured basilar membrane and lateral compartment vibration in transgenic mice with targeted alterations in cochlear mechanics. Prestin499/499, Prestin−/−, and TectaC1509G/C1509G mice demonstrated no cochlear amplification but maintained the lateral compartment phase difference. In contrast, SfswapTg/Tg mice maintained cochlear amplification but did not demonstrate the lateral compartment phase difference. These data indicate that the organ of Corti has complex micromechanical vibratory characteristics, with passive, yet sharply tuned, vibratory characteristics associated with the supporting cells. These characteristics may tune OHC force generation to produce the sharp frequency selectivity of mammalian hearing. PMID:24920025
Park, Edward; Amoodi, Hosam; Kuthubutheen, Jafri; Chen, Joseph M; Nedzelski, Julian M; Lin, Vincent Y W
2015-05-28
Cochlear implantation has become a mainstream treatment option for patients with severe to profound sensorineural hearing loss. During cochlear implant, there are key surgical steps which are influenced by anatomical variations between each patient. The aim of this study is to determine if there are potential predictors of difficulties that may be encountered during the cortical mastoidectomy, facial recess approach and round window access in cochlear implant surgery based upon pre-operative temporal bone CT scan. Fifty seven patients undergoing unilateral cochlear implantation were analyzed. Difficulty with 1) cortical mastoidectomy, 2) facial recess approach, and 3) round window access were scored intra-operatively by the surgeon in a blinded fashion (1 = "easy", 2 = "moderate", 3 = "difficult"). Pre-operative temporal bone CT scans were analyzed for 1) degree of mastoid aeration; 2) location of the sigmoid sinus; 3) height of the tegmen; 4) the presence of air cells in the facial recess, and 5) degree of round window bony overhang. Poor mastoid aeration and lower tegmen position, but not the location of sigmoid sinus, are associated with greater difficulty with the cortical mastoidectomy. Presence of an air cell around the facial nerve was predictive of easier facial recess access. However, the degree of round window bony overhang was not predictive of difficulty associated with round window access. Certain parameters on the pre-operative temporal bone CT scan may be useful in predicting potential difficulties encountered during the key steps involved in cochlear implant surgery.
Cochlear implant performance in children deafened by congenital cytomegalovirus-A systematic review.
Kraaijenga, V J C; Van Houwelingen, F; Van der Horst, S F; Visscher, J; Huisman, J M L; Hollman, E J; Stegeman, I; Smit, A L
2018-05-16
Congenital cytomegalovirus (cCMV) infection is a major cause of sensorineural hearing loss in children. The objective of this systematic review was to compare performance in paediatric cochlear implant users with SNHL caused by cCMV compared to non-cCMV implantees. Systematic review SEARCH STRATEGY: PubMed, EMBASE and the Cochrane databases were searched from inception up to 15 May 2017 for children, cochlear implant, performance and their synonyms. Titles, abstracts and full texts were screened for eligibility. Directness of evidence and risk of bias were assessed. From the included studies, study characteristics and outcome data (speech perception, speech production, receptive language and auditory performance of cCMV groups and non-cCMV groups) were extracted. A total of 5280 unique articles were screened of which 28 were eligible for critical appraisal. After critical appraisal, 12 studies remained for data extraction. Seven of 12 studies showed worse performance after cochlear implantation in cCMV children compared to non-cCMV children. Worse performance in cCMV children was attributed to cCMV-related comorbidities in six of these studies. Available data on asymptomatic cCMV children compared to non-cCMV children did not reveal an unfavourable effect on cochlear implant performance. The available evidence reveals that cCMV children often have worse cochlear implant performance compared to non-cCMV children, which can be attributed to cCMV related comorbidities. We urge physicians to take into account the cCMV related comorbidities in the counselling of paediatric CI users deafened by cCMV. © 2018 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.
Xie, Joanna; Pak, Kwang; Evans, Amaretta; Kamgar-Parsi, Andy; Fausti, Stephen; Mullen, Lina; Ryan, Allen Frederic
2013-01-01
The electrodes of a cochlear implant are located far from the surviving neurons of the spiral ganglion, which results in decreased precision of neural activation compared to the normal ear. If the neurons could be induced to extend neurites toward the implant, it might be possible to stimulate more discrete subpopulations of neurons, and to increase the resolution of the device. However, a major barrier to neurite growth toward a cochlear implant is the fluid filling the scala tympani, which separates the neurons from the electrodes. The goal of this study was to evaluate the growth of cochlear neurites in three-dimensional extracellular matrix molecule gels, and to increase biocompatibility by using fibroblasts stably transfected to produce neurotrophin-3 and brain-derived neurotrophic factor. Spiral ganglion explants from neonatal rats were evaluated in cultures. They were exposed to soluble neurotrophins, cells transfected to secrete neurotrophins, and/or collagen gels. We found that cochlear neurites grew readily on collagen surfaces and in three-dimensional collagen gels. Co-culture with cells producing neurotrophin-3 resulted in increased numbers of neurites, and neurites that were longer than when explants were cultured with control fibroblasts stably transfected with green fluorescent protein. Brain-derived neurotrophic factor-producing cells resulted in a more dramatic increase in the number of neurites, but there was no significant effect on neurite length. It is suggested that extracellular matrix molecule gels and cells transfected to produce neurotrophins offer an opportunity to attract spiral ganglion neurites toward a cochlear implant. PMID:24459465
Bertlich, Mattis; Ihler, Friedrich; Weiss, Bernhard G; Freytag, Saskia; Strupp, Michael; Canis, Martin
2017-12-01
The aim of this work was to evaluate the effect of tumor necrosis factor (TNF) and its neutralization with etanercept on the capability of cochlear pericytes to alter capillary diameter in the stria vascularis. Twelve Dunkin-Hartley guinea pigs were randomly assigned to one of three groups. Each group was treated either with placebo and then placebo, TNF and then placebo, or TNF and then etanercept. Cochlear pericytes were visualized using diaminofluorescein-2-diacetate and intravasal blood flow by fluorescein-dextrane. Vessel diameter at sites of pericyte somas and downstream controls were quantified by specialized software. Values were obtained before treatment, after first treatment with tumor necrosis factor or placebo and after second treatment with etanercept or placebo. Overall, 199 pericytes in 12 animals were visualized. After initial treatment with TNF, a significant decrease in vessel diameter at sites of pericyte somas (3.6 ±4.3%, n = 141) compared with placebo and downstream controls was observed. After initial treatment with TNF, the application of etanercept caused a significant increase (3.3 ±5.5%, n = 59) in vessel diameter at the sites of pericyte somata compared with placebo and downstream controls. We have been able to show that cochlear pericytes are capable of reducing capillary diameter after exposition to TNF. Moreover, the reduction in capillary diameter observed after the application of TNF is revertible after neutralization of tumor necrosis factor by the application of etanercept. It seems that contraction of cochlear pericytes contributes to the regulation of cochlear blood flow.
Hyaluronic acid enhances gene delivery into the cochlea.
Shibata, Seiji B; Cortez, Sarah R; Wiler, James A; Swiderski, Donald L; Raphael, Yehoash
2012-03-01
Cochlear gene therapy can be a new avenue for the treatment of severe hearing loss by inducing regeneration or phenotypic rescue. One necessary step to establish this therapy is the development of a safe and feasible inoculation surgery, ideally without drilling the bony cochlear wall. The round window membrane (RWM) is accessible in the middle-ear space, but viral vectors placed on this membrane do not readily cross the membrane to the cochlear tissues. In an attempt to enhance permeability of the RWM, we applied hyaluronic acid (HA), a nontoxic and biodegradable reagent, onto the RWM of guinea pigs, prior to delivering an adenovirus carrying enhanced green fluorescent protein (eGFP) reporter gene (Ad-eGFP) at the same site. We examined distribution of eGFP in the cochlea 1 week after treatment, comparing delivery of the vector via the RWM, with or without HA, to delivery by a cochleostomy into the perilymph. We found that cochlear tissue treated with HA-assisted delivery of Ad-eGFP demonstrated wider expression of transgenes in cochlear cells than did tissue treated by cochleostomy injection. HA-assisted vector delivery facilitated expression in cells lining the scala media, which are less accessible and not transduced after perilymphatic injection. We assessed auditory function by measuring auditory brainstem responses and determined that thresholds were significantly better in the ears treated with HA-assisted Ad-eGFP placement on the RWM as compared with cochleostomy. Together, these data demonstrate that HA-assisted delivery of viral vectors provides an atraumatic and clinically feasible method to introduce transgenes into cochlear cells, thereby enhancing both research methods and future clinical application.
Miyagawa, Maiko; Nishio, Shin-Ya; Usami, Shin-Ichi
2016-01-01
Objective: Cochlear implantation is the most important treatment currently available for profound sensorineural hearing loss. The aim of this study was to investigate the etiology of hearing loss in patients with cochlear implantation, and to compare outcomes. Methods: Japanese hearing loss patients who received cochlear implants (CIs) or electric acoustic stimulation (EAS) in Shinshu University hospital (n = 173, prelingual onset: 92, postlingual onset: 81) participated in this study. Invader assay followed by the targeted exon-sequencing of 63 deafness genes using Massively parallel DNA sequencing (MPS) was applied. For prelingual patients, additional imaging examination, cCMV screening, and pediatric examination were performed for precise diagnosis. Results: Genetic screening successfully identified the causative mutation in 60% of patients with prelingual onset hearing loss and in 36% of those with postlingual hearing loss. Differences in the kinds of genes identified were observed between the two groups. Although there were marked variations in the outcome of cochlear implantation, patients with specific deafness gene mutations showed relatively good results. Conclusion: The present study showed genetic etiology is a major cause of hearing loss in CI/EAS patients. Patients possessing mutations in a number of deafness genes known to be expressed within inner ear have achieved satisfactory auditory performance, suggesting that the identification of the genetic background facilitates the prediction of post-CI performance. MPS is a powerful tool for the identification of causative deafness genes in patients receiving cochlear implantation. Therefore, determination of the involved region inside/outside of the cochlea by identification of the responsible gene is essential. PMID:26756145
Audiological outcomes of cochlear implantation in Waardenburg Syndrome.
Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira
2013-07-01
The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.
Landsberger, David M.; Vermeire, Katrien; Claes, Annes; Van Rompaey, Vincent; Van de Heyning, Paul
2015-01-01
Objectives Although it has been previously shown that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. We hypothesized that although temporal coding may provide useable information at any cochlear location, low rates of stimulation might provide better sound quality in apical regions that are more likely to encode temporal information in the normal ear. In the present study, sound qualities of single electrode pulse trains were scaled to provide insight into the combined effects of cochlear location and stimulation rate on sound quality. Design Ten long term users of MED-EL cochlear implants with 31 mm electrode arrays (Standard or FLEXSOFT) were asked to scale the sound quality of single electrode pulse trains in terms of how “Clean”, “Noisy”, “High”, and “Annoying” they sounded. Pulse trains were presented on most electrodes between 1 and 12 representing the entire range of the long electrode array at stimulation rates of 100, 150, 200, 400, or 1500 pulses per second. Results While high rates of stimulation are scaled as having a “Clean” sound quality across the entire array, only the most apical electrodes (typically 1 through 3) were considered “Clean” at low rates. Low rates on electrodes 6 through 12 were not rated as “Clean” while the low rate quality of electrodes 4 and 5 were typically in between. Scaling of “Noisy” responses provided an approximately inverse pattern as “Clean” responses. “High” responses show the trade-off between rate and place of stimulation on pitch. Because “High” responses did not correlate with “Clean” responses, subjects were not rating sound quality based on pitch. Conclusions If explicit temporal coding is to be provided in a cochlear implant, it is likely to sound better when provided apically. Additionally, the finding that low rates sound clean only at apical places of stimulation is consistent with previous findings that a change in rate of stimulation corresponds to an equivalent change in perceived pitch at apical locations. Collectively, the data strongly suggests that temporal coding with a cochlear implant is optimally provided by electrodes placed well into the second cochlear turn. PMID:26583480
Winn, Matthew B; Won, Jong Ho; Moon, Il Joon
This study was conducted to measure auditory perception by cochlear implant users in the spectral and temporal domains, using tests of either categorization (using speech-based cues) or discrimination (using conventional psychoacoustic tests). The authors hypothesized that traditional nonlinguistic tests assessing spectral and temporal auditory resolution would correspond to speech-based measures assessing specific aspects of phonetic categorization assumed to depend on spectral and temporal auditory resolution. The authors further hypothesized that speech-based categorization performance would ultimately be a superior predictor of speech recognition performance, because of the fundamental nature of speech recognition as categorization. Nineteen cochlear implant listeners and 10 listeners with normal hearing participated in a suite of tasks that included spectral ripple discrimination, temporal modulation detection, and syllable categorization, which was split into a spectral cue-based task (targeting the /ba/-/da/ contrast) and a timing cue-based task (targeting the /b/-/p/ and /d/-/t/ contrasts). Speech sounds were manipulated to contain specific spectral or temporal modulations (formant transitions or voice onset time, respectively) that could be categorized. Categorization responses were quantified using logistic regression to assess perceptual sensitivity to acoustic phonetic cues. Word recognition testing was also conducted for cochlear implant listeners. Cochlear implant users were generally less successful at utilizing both spectral and temporal cues for categorization compared with listeners with normal hearing. For the cochlear implant listener group, spectral ripple discrimination was significantly correlated with the categorization of formant transitions; both were correlated with better word recognition. Temporal modulation detection using 100- and 10-Hz-modulated noise was not correlated either with the cochlear implant subjects' categorization of voice onset time or with word recognition. Word recognition was correlated more closely with categorization of the controlled speech cues than with performance on the psychophysical discrimination tasks. When evaluating people with cochlear implants, controlled speech-based stimuli are feasible to use in tests of auditory cue categorization, to complement traditional measures of auditory discrimination. Stimuli based on specific speech cues correspond to counterpart nonlinguistic measures of discrimination, but potentially show better correspondence with speech perception more generally. The ubiquity of the spectral (formant transition) and temporal (voice onset time) stimulus dimensions across languages highlights the potential to use this testing approach even in cases where English is not the native language.
Helmstaedter, Victor; Lenarz, Thomas; Erfurt, Peter; Kral, Andrej; Baumhoff, Peter
2017-12-14
For the increasing number of cochlear implantations in subjects with residual hearing, hearing preservation, and thus the prevention of implantation trauma, is crucial. A method for monitoring the intracochlear position of a cochlear implant (CI) and early indication of imminent cochlear trauma would help to assist the surgeon to achieve this goal. The aim of this study was to evaluate the reliability of the different electric components recorded by an intracochlear electrocochleography (ECochG) as markers for the cochleotopic position of a CI. The measurements were made directly from the CI, combining intrasurgical diagnostics with the therapeutical use of the CI, thus, turning the CI into a "theragnostic probe." Intracochlear ECochGs were measured in 10 Dunkin Hartley guinea pigs of either sex, with normal auditory brainstem response thresholds. All subjects were fully implanted (4 to 5 mm) with a custom six contact CI. The ECochG was recorded simultaneously from all six contacts with monopolar configuration (retroauricular reference electrode). The gross ECochG signal was filtered off-line to separate three of its main components: compound action potential, cochlear microphonic, and summating potential (SP). Additionally, five cochleae were harvested and histologically processed to access the spatial position of the CI contacts. Both ECochG data and histological reconstructions of the electrode position were fitted with the Greenwood function to verify the reliability of the deduced cochleotopic position of the CI. SPs could be used as suitable markers for the frequency position of the recording electrode with an accuracy of ±1/4 octave in the functioning cochlea, verified by histology. Cochlear microphonics showed a dependency on electrode position but were less reliable as positional markers. Compound action potentials were not suitable for CI position information but were sensitive to "cochlear health" (e.g., insertion trauma). SPs directly recorded from the contacts of a CI during surgery can be used to access the intracochlear frequency position of the CI. Using SP monitoring, implantation may be stopped before penetrating functioning cochlear regions. If the technique was similarly effective in humans, it could prevent implantation trauma and increase hearing preservation during CI surgery. Diagnostic hardware and software for recording biological signals with a CI without filter limitations might be a valuable add-on to the portfolios of CI manufacturers.
Manzoor, Nauman F; Wick, Cameron C; Wahba, Marian; Gupta, Amit; Piper, Robin; Murray, Gail S; Otteson, Todd; Megerian, Cliff A; Semaan, Maroun T
2016-02-01
To analyze audiometric outcomes after bilateral cochlear implantation in patients with isolated enlarged vestibular aqueduct (EVA) syndrome and associated incomplete partition (IP) malformations. Secondary objective was to analyze rate of cerebrospinal fluid (CSF) gusher in patients with IP-EVA spectrum deformities and compare this with the existing literature. Retrospective chart review. Thirty-two patients with EVA syndrome who received unilateral or bilateral cochlear implants between June 1999 and January 2014 were identified in the University Hospitals Case Medical Center cochlear implant database. Isolated EVA (IEVA) and Incomplete Partition Type II (IP-II) malformations were identified by reviewing high-resolution computed tomography (HRCT) imaging. Demographic information, age at implantation, surgical details, postimplantation audiometric data including speech reception thresholds (SRT), word, and sentence scores were reviewed and analyzed. Intra- and postoperative complications were analyzed as well and compared with the literature. Seventeen patients (32 implanted ears) had pediatric cochlear implantation for EVA-associated hearing loss. Data from 16 controls (32 implanted ears) were used to compare audiometric and speech outcomes of EVA cohort. Mean age at implantation was 6.8 years for EVA cohort and 6.0 years for controls. There was no statistically significant difference in long-term postoperative SRT, monaurally aided word scores, and binaurally tested word scores between pediatric EVA group and controls. The EVA patients had a long-term mean sentence score of 85.92%. A subset of EVA patients implanted at mean age of 3.18 years (n = 15 ears) had similar audiometric outcomes to another control group with Connexin 26 mutations (n = 20 ears) implanted at a similar age. Further subset analysis revealed no significant differences in age at implantation, SRT, and word scores in patients with IEVA and IP-II malformation. There was no significant association between size of vestibular aqueduct and age at implantation. There was no CSF gusher or other intra- or postoperative complications reported in our series. Bilateral sequential cochlear implantation can be performed safely in patients with EVA. Audiometric outcomes are excellent and comparable to pediatric cochlear implant patients with no malformations. CSF gusher rates can be minimized by trans-round window approach. Further long-term studies are needed to identify differences within IP-EVA spectrum deformities, audiometric outcomes, and proportions of EVA patients who will need cochlear implantation for hearing rehabilitation.
Hudson, V E; Elniel, A; Ughratdar, I; Zebian, B; Selway, R; Lin, J P
2017-01-01
Cochlear implants for sensorineural deafness in children is one of the most successful neuromodulation techniques known to relieve early chronic neurodisability, improving activity and participation. In 2012 there were 324,000 recipients of cochlear implants globally. To compare cochlear implant (CI) neuromodulation with deep brain stimulation (DBS) for dystonia in childhood and explore relations between age and duration of symptoms at implantation and outcome. Comparison of published annual UK CI figures for 1985-2009 with a retrospective cohort of the first 9 years of DBS for dystonia in children at a single-site Functional Neurosurgery unit from 2006 to 14. From 2006 to 14, DBS neuromodulation of childhood dystonia increased by a factor of 3.8 to a total of 126 cases over the first 9 years, similar to the growth in cochlear implants which increased by a factor of 4.1 over a similar period in the 1980s rising to 527 children in 2009. The CI saw a dramatic shift in practice from implantation at >5 years of age at the start of the programme towards earlier implantation by the mid-1990s. Best language results were seen for implantation <5 years of age and duration of cochlear neuromodulation >4 years, hence implantation <1 year of age, indicating that severely deaf, pre-lingual children could benefit from cochlear neuromodulation if implanted early. Similar to initial CI use, the majority of children receiving DBS for dystonia in the first 9 years were 5-15 years of age, when the proportion of life lived with dystonia exceeds 90% thus limiting benefits. Early DBS neuromodulation for acquired motor disorders should be explored to maximise the benefits of dystonia reduction in a period of maximal developmental plasticity before the onset of disability. Learning from cochlear implantation, DBS can become an accepted management option in children under the age of 5 years who have a reduced proportion of life lived with dystonia, and not viewed as a last resort reserved for only the most severe cases where benefits may be at their most limited. Copyright © 2016 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Progressive Susac syndrome with bilateral visual loss and disability.
Entezari, Morteza; Karimi, Saeed; Feizi, Mohammadali
2016-09-01
Susac syndrome (SS) is a rare retinal-cochlear-cerebral disease with an unclear etiology. A 35-year-old man presented with sudden painless vision loss in the right eye and 2 months later in the left eye with hemiparesis, behavioral changes, and hearing loss. Ophthalmic examinations revealed multiple branch retinal artery occlusions (BRAOs) in both eyes. Brain magnetic resonance imaging showed inflammatory changes with multiple "punched-out" lesions in the corpus callosum which confirmed the diagnosis of SS. Despite intravenous and oral corticosteroid therapy, the disease progressed with the development of new BRAOs, low vision in both eyes, and disability. Prompt diagnosis and early treatment may save the vision and even patient's life.
Fukushima, Kunihiro; Kawasaki, Akihiro; Nagayasu, Rie; Kunisue, Kazuya; Maeda, Yukihide; Kariya, Shin; Kataoka, Yuko; Nishizaki, Kazunori
2008-06-01
Learning disability combined with hearing impairment (LDHI) is a poor prognostic factor for the language development of hearing impaired children after educational intervention. A typical example of a child with LDHI and effective interventions provided by cochlear implants are presented in this report. A case of congenital cytomegaloviral infection that showed dysgraphia as well as profound deafness was reported and an underlying visual processing problem diagnosed in the present case caused the patient's dysgraphia. The dysgraphia could be circumvented by the use of auditory memory fairly established by a cochlear implant.
Bilateral and Unilateral Cochlear Implant Users Compared on Speech Perception in Noise
Dunn, Camille C.; Noble, William; Tyler, Richard S.; Kordus, Monika; Gantz, Bruce J.; Ji, Haihong
2009-01-01
Objective Compare speech performance in noise with matched bilateral (CICI) and unilateral (CI-Only) cochlear implant users. Design Thirty CICI and 30 CI-Only subjects were tested on a battery of speech perception tests in noise that utilize an 8-loudspeaker array. Results On average, CICI subject's performance with speech in noise was significantly better than the CI-Only subjects. Conclusion The CICI group showed significantly better performance on speech perception in noise compared to the CI-Only subjects, supporting the hypothesis that bilateral cochlear implantation is more beneficial than unilateral implantation. PMID:19858720
Spoken language skills and educational placement in Finnish children with cochlear implants.
Lonka, Eila; Hasan, Marja; Komulainen, Erkki
2011-01-01
This study reports the demographics, and the auditory and spoken language development as well as educational settings, for a total of 164 Finnish children with cochlear implants. Two questionnaires were employed: the first, concerning day care and educational placement, was filled in by professionals for rehabilitation guidance, and the second, evaluating language development (categories of auditory performance, spoken language skills, and main mode of communication), by speech and language therapists in audiology departments. Nearly half of the children were enrolled in normal kindergartens and 43% of school-aged children in mainstream schools. Categories of auditory performance were observed to grow in relation to age at cochlear implantation (p < 0.001) as well as in relation to proportional hearing age (p < 0.001). The composite scores for language development moved to more diversified ones in relation to increasing age at cochlear implantation and proportional hearing age (p < 0.001). Children without additional disorders outperformed those with additional disorders. The results indicate that the most favorable age for cochlear implantation could be earlier than 2. Compared to other children, spoken language evaluation scores of those with additional disabilities were significantly lower; however, these children showed gradual improvements in their auditory perception and language scores. Copyright © 2011 S. Karger AG, Basel.
Ihler, Friedrich; Pelz, Sabrina; Coors, Melanie; Matthias, Christoph; Canis, Martin
2014-11-01
Cochlear implantation trauma causes both macroscopic and inflammatory trauma. The aim of the present study was to evaluate the effectiveness of the TNF-alpha inhibitor etanercept applied after cochlear implantation trauma on the preservation of acoustic hearing. Guinea pigs were randomly assigned to three groups receiving cochlear implantation trauma by cochleostomy. In one group, the site was sealed by bone cement with no further treatment. A second group was additionally implanted with an osmotic minipump delivering artificial perilymph into the scala tympani for seven days. In the third group, etanercept 1 mg/ml was added to artificial perilymph. Hearing was assessed by auditory brainstem responses at 2, 4, 6, and 8 kHz prior to and after surgery and on days 3, 5, 7, 14, 28. Fifteen healthy guinea pigs. The trauma led to threshold shifts from 50.3 dB ± 16.3 dB to 68.0 dB ± 19.3 dB. Hearing thresholds were significantly lower in etanercept-treated animals compared to controls on day 28 at 8 kHz and from day 3 onwards at 4 and 2 kHz (p < 0.01; two-way RM ANOVA / Bonferroni t-test). The application of etanercept led to preservation of acoustic hearing after cochlear implantation trauma.
Olivetto, E; Simoni, E; Guaran, V; Astolfi, L; Martini, A
2015-09-01
Hearing loss may be genetic, associated with aging or exposure to noise or ototoxic substances. Its aetiology can be attributed to vascular injury, trauma, tumours, infections or autoimmune response. All these factors could be related to alterations in cochlear microcirculation resulting in hypoxia, which in turn may damage cochlear hair cells and neurons, leading to deafness. Hypoxia could underlie the aetiology of deafness, but very few data about it are presently available. The aim of this work is to develop animal models of hypoxia and ischemia suitable for study of cochlear vascular damage, characterizing them by electrophysiology and gene/protein expression analyses. The effects of hypoxia in infarction were mimicked in rat by partial permanent occlusion of the left coronary artery, and those of ischemia in thrombosis by complete temporary carotid occlusion. In our models both hypoxia and ischemia caused a small but significant hearing loss, localized at the cochlear apex. A slight induction of the coagulation cascade and of oxidative stress pathways was detected as cell survival mechanism, and cell damages were found on the cuticular plate of outer hair cells only after carotid ischemia. Based on these data, the two developed models appear suitable for in vivo studies of cochlear vascular damage. Copyright © 2015 Elsevier B.V. All rights reserved.
Quittner, Alexandra L; Cejas, Ivette; Wang, Nae-Yuh; Niparko, John K; Barker, David H
2016-01-01
In the largest, longitudinal study of young, deaf children before and three years after cochlear implantation, we compared symbolic play and novel noun learning to age-matched hearing peers. Participants were 180 children from six cochlear implant centers and 96 hearing children. Symbolic play was measured during five minutes of videotaped, structured solitary play. Play was coded as "symbolic" if the child used substitution (e.g., a wooden block as a bed). Novel noun learning was measured in 10 trials using a novel object and a distractor. Cochlear implant vs. normal hearing children were delayed in their use of symbolic play, however, those implanted before vs. after age two performed significantly better. Children with cochlear implants were also delayed in novel noun learning (median delay 1.54 years), with minimal evidence of catch-up growth. Quality of parent-child interactions was positively related to performance on the novel noun learning, but not symbolic play task. Early implantation was beneficial for both achievement of symbolic play and novel noun learning. Further, maternal sensitivity and linguistic stimulation by parents positively affected noun learning skills, although children with cochlear implants still lagged in comparison to hearing peers.
Interaction of tinnitus suppression and hearing ability after cochlear implantation.
Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming
2017-10-01
To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p < .001). The study suggests six-month CI activation can be effective for suppressing tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.
The Role of Organ of Corti Mass in Passive Cochlear Tuning
de La Rochefoucauld, Ombeline; Olson, Elizabeth S.
2007-01-01
The mechanism for passive cochlear tuning remains unsettled. Early models considered the organ of Corti complex (OCC) as a succession of spring-mass resonators. Later, traveling wave models showed that passive tuning could arise through the interaction of cochlear fluid mass and OCC stiffness without local resonators. However, including enough OCC mass to produce local resonance enhanced the tuning by slowing and thereby growing the traveling wave as it approached its resonant segment. To decide whether the OCC mass plays a role in tuning, the frequency variation of the wavenumber of the cochlear traveling wave was measured (in vivo, passive cochleae) and compared to theoretical predictions. The experimental wavenumber was found by taking the phase difference of basilar membrane motion between two longitudinally spaced locations and dividing by the distance between them. The theoretical wavenumber was a solution of the dispersion relation of a three-dimensional cochlear model with OCC mass and stiffness as the free parameters. The experimental data were only well fit by a model that included OCC mass. However, as the measurement position moved from a best-frequency place of 40 to 12 kHz, the role of mass was diminished. The notion of local resonance seems to only apply in the very high-frequency region of the cochlea. PMID:17905841
A mathematical model of vowel identification by users of cochlear implants
Sagi, Elad; Meyer, Ted A.; Kaiser, Adam R.; Teoh, Su Wooi; Svirsky, Mario A.
2010-01-01
A simple mathematical model is presented that predicts vowel identification by cochlear implant users based on these listeners’ resolving power for the mean locations of first, second, and∕or third formant energies along the implanted electrode array. This psychophysically based model provides hypotheses about the mechanism cochlear implant users employ to encode and process the input auditory signal to extract information relevant for identifying steady-state vowels. Using one free parameter, the model predicts most of the patterns of vowel confusions made by users of different cochlear implant devices and stimulation strategies, and who show widely different levels of speech perception (from near chance to near perfect). Furthermore, the model can predict results from the literature, such as Skinner, et al. [(1995). Ann. Otol. Rhinol. Laryngol. 104, 307–311] frequency mapping study, and the general trend in the vowel results of Zeng and Galvin’s [(1999). Ear Hear. 20, 60–74] studies of output electrical dynamic range reduction. The implementation of the model presented here is specific to vowel identification by cochlear implant users, but the framework of the model is more general. Computational models such as the one presented here can be useful for advancing knowledge about speech perception in hearing impaired populations, and for providing a guide for clinical research and clinical practice. PMID:20136228
Skarzynski, Henryk; Lorens, Artur; Kruszynska, Marika; Obrycka, Anita; Pastuszak, Dorota; Skarzynski, Piotr Henryk
2017-07-01
Cochlear implants improve the hearing abilities of individuals with unilateral hearing loss and no tinnitus. The benefit is no different from that seen in patients with unilateral hearing loss and incapacitating tinnitus. To evaluate hearing outcomes after cochlear implantation in individuals with unilateral hearing loss and no tinnitus and compare them to those obtained in a similar group who had incapacitating tinnitus. Six cases who did not experience tinnitus before operation and 15 subjects with pre-operative tinnitus were evaluated with a structured interview, a monosyllabic word test under difficult listening situations, a sound localization test, and an APHAB (abbreviated profile of hearing aid benefit) questionnaire. All subjects used their cochlear implant more than 8 hours a day, 7 days a week. In 'no tinnitus' patients, mean benefit of cochlear implantation was 19% for quiet speech, 15% for speech in noise (with the same signal-to-noise ratio in the implanted and non-implanted ear), and 16% for a more favourable signal-to-noise ratio at the implanted ear. Sound localization error improved by an average of 19°. The global score of APHAB improved by 16%. The benefits across all evaluations did not differ significantly between the 'no tinnitus' and 'tinnitus' groups.
Examining the communication skills of a young cochlear implant pioneer.
Connor, Carol McDonald
2006-01-01
The purpose of this longitudinal case study was to closely examine one deaf child's experience with a cochlear implant and his speech, language, and communication skills from kindergarten through middle and high school using both developmental and sociocultural frameworks. The target child was one of the first children to receive a cochlear implant in the United States in 1988, when he was 5 years of age. The developmental analysis revealed that prior to receiving a cochlear implant the child demonstrated profound delays in speech and language skill development. His speech and language skills grew slowly during the first 3-4 years following implantation, very rapidly from about 5 through 7 years postimplantation, then slowed to rates that were highly similar to same-age peers with normal hearing. The sociocultural analysis revealed that the child's communicative competence improved; that he used sign language but use of sign language decreased as his oral communication skills improved; that as his oral communication skills improved, the adults talked and directed the topic of conversation less frequently; and that topics became less concrete and more personal over time. The results of this study indicate that we may learn more about how to support children who use cochlear implants by examining what they are saying as well as how they are saying it.
Cochlear partition tuning within the 2nd apical turn of the intact gerbil cochlea
NASA Astrophysics Data System (ADS)
Dong, Wei; Xia, Anping; Puria, Sunil; Applegate, Brian E.; Oghalai, John S.
2018-05-01
Our understanding of cochlear amplification has been mainly informed by observations of the high-frequency basal region. Results from the few existing in vivo studies from the low-frequency apical region have suggested that cochlear amplification may be more broadly tuned and not as nonlinear as in the base. The current study explored micromechanics via sound evoked vibrations of the cochlear partition, including the organ of Corti (OoC), the basilar membrane (BM) and the tectorial membrane (TM), within the 2nd apical turn, corresponding to the 2.5 kHz best frequency region, of the gerbil cochlea using volumetric optical coherence tomography vibrometry (VOCTV), imaged non-invasively through the otic capsule bone in vivo. Sound induced radial displacements below 4 kHz showed similarities and differences to the well-established BM transverse responses at high-frequency basal region. Responses showed broader tuning, but similar gains at the best frequency and similar phase accumulation. The distinct difference found was the presence of compressive nonlinear growth with SPL below the best frequency down to 0.1 kHz observed at the outer hair cell (OHC) and reticular laminar (RL) locations but not in the BM or inner hair cell regions. These relative motions provide further insight on how OHC somatic forces are distributed within the cochlear partition.
Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation
Schurzig, Daniel; Labadie, Robert F.; Hussong, Andreas; Rau, Thomas S.; Webster, Robert J.
2012-01-01
The quality of hearing restored to a deaf patient by a cochlear implant in hearing preservation cochlear implant surgery (and possibly also in routine cochlear implant surgery) is believed to depend on preserving delicate cochlear membranes while accurately inserting an electrode array deep into the spiral cochlea. Membrane rupture forces, and possibly, other indicators of suboptimal placement, are below the threshold detectable by human hands, motivating a force sensing insertion tool. Furthermore, recent studies have shown significant variability in manual insertion forces and velocities that may explain some instances of imperfect placement. Toward addressing this, an automated insertion tool was recently developed by Hussong et al. By following the same insertion tool concept, in this paper, we present mechanical enhancements that improve the surgeon’s interface with the device and make it smaller and lighter. We also present electomechanical design of new components enabling integrated force sensing. The tool is designed to be sufficiently compact and light that it can be mounted to a microstereotactic frame for accurate image-guided preinsertion positioning. The new integrated force sensing system is capable of resolving forces as small as 0.005 N, and we provide experimental illustration of using forces to detect errors in electrode insertion. PMID:23482414
The mechanical waveform of the basilar membrane. IV. Tone and noise stimuli
NASA Astrophysics Data System (ADS)
de Boer, Egbert; Nuttall, Alfred L.
2002-02-01
Analysis of mechanical cochlear responses to wide bands of random noise clarifies many effects of cochlear nonlinearity. The previous paper [de Boer and Nuttall, J. Acoust. Soc. Am. 107, 1497-1507 (2000)] illustrates how closely results of computations in a nonlinear cochlear model agree with responses from physiological experiments. In the present paper results for tone stimuli are reported. It was found that the measured frequency response for pure tones differs little from the frequency response associated with a noise signal. For strong stimuli, well into the nonlinear region, tones have to be presented at a specific level with respect to the noise for this to be true. In this report the nonlinear cochlear model originally developed for noise analysis was modified to accommodate pure tones. For this purpose the efficiency with which outer hair cells modify the basilar-membrane response was made into a function of cochlear location based on local excitation. For each experiment, the modified model is able to account for the experimental findings, within 1 or 2 dB. Therefore, the model explains why the type of filtering that tones undergo in the cochlea is essentially the same as that for noise signals (provided the tones are presented at the appropriate level).
Qi, Beier; Liu, Bo; Liu, Sha; Liu, Haihong; Dong, Ruijuan; Zhang, Ning; Gong, Shusheng
2011-05-01
To study the effect of cochlear electrode coverage and different insertion region on speech recognition, especially tone perception of cochlear implant users whose native language is Mandarin Chinese. Setting seven test conditions by fitting software. All conditions were created by switching on/off respective channels in order to simulate different insertion position. Then Mandarin CI users received 4 Speech tests, including Vowel Identification test, Consonant Identification test, Tone Identification test-male speaker, Mandarin HINT test (SRS) in quiet and noise. To all test conditions: the average score of vowel identification was significantly different, from 56% to 91% (Rank sum test, P < 0.05). The average score of consonant identification was significantly different, from 72% to 85% (ANOVNA, P < 0.05). The average score of Tone identification was not significantly different (ANOVNA, P > 0.05). However the more channels activated, the higher scores obtained, from 68% to 81%. This study shows that there is a correlation between insertion depth and speech recognition. Because all parts of the basement membrane can help CI users to improve their speech recognition ability, it is very important to enhance verbal communication ability and social interaction ability of CI users by increasing insertion depth and actively stimulating the top region of cochlear.
Differential Effects of AAV.BDNF and AAV.Ntf3 in the Deafened Adult Guinea Pig Ear
Budenz, Cameron L.; Wong, Hiu Tung; Swiderski, Donald L.; Shibata, Seiji B.; Pfingst, Bryan E.; Raphael, Yehoash
2015-01-01
Cochlear hair cell loss results in secondary regression of peripheral auditory fibers (PAFs) and loss of spiral ganglion neurons (SGNs). The performance of cochlear implants (CI) in rehabilitating hearing depends on survival of SGNs. Here we compare the effects of adeno-associated virus vectors with neurotrophin gene inserts, AAV.BDNF and AAV.Ntf3, on guinea pig ears deafened systemically (kanamycin and furosemide) or locally (neomycin). AAV.BDNF or AAV.Ntf3 was delivered to the guinea pig cochlea one week following deafening and ears were assessed morphologically 3 months later. At that time, neurotrophins levels were not significantly elevated in the cochlear fluids, even though in vitro and shorter term in vivo experiments demonstrate robust elevation of neurotrophins with these viral vectors. Nevertheless, animals receiving these vectors exhibited considerable re-growth of PAFs in the basilar membrane area. In systemically deafened animals there was a negative correlation between the presence of differentiated supporting cells and PAFs, suggesting that supporting cells influence the outcome of neurotrophin over-expression aimed at enhancing the cochlear neural substrate. Counts of SGN in Rosenthal's canal indicate that BDNF was more effective than NT-3 in preserving SGNs. The results demonstrate that a transient elevation in neurotrophin levels can sustain the cochlear neural substrate in the long term. PMID:25726967
Zhao, Jing; Sun, Jianjun; Liu, Yang
2012-10-01
Disturbances of microcirculation and hemorheological changes in the inner ear are the results of noise-induced hearing loss (NIHL). Both the disturbances of microcirculation and hemorheological changes are the etiologies of NIHL development, but they are also the results. Although previous reports that inhalation of high concentration of CO(2) may increase cochlear blood flow (CoBF), the effects of carbogen on the cochlear microcirculation and NIHL remain unclear. Changes induced by noise, carbogen and pure oxygen within the cochlear lateral wall microvasculature and in hearing thresholds were observed in guinea pigs using intravital microscopy and the auditory brainstem response. At the same time, arterial oxygen saturation and morphologic changes of cochlear hair cells were observed. Carbogen inhalation increased vessel diameters and blood flow velocities. Hearing thresholds elevation in the carbogen group was smaller than those in the control and oxygen group (p <0.05). Carbogen inhalation produced a trend toward less threshold shift after noise exposure, which reached statistical significance after day 3 (p <0.01). Respiratory acidosis was not found in our study. The segmented basal membranes of Corti in three groups indicated that no losses or discorders of hair cells were found. Carbogen inhalation can preserve hearing in animal models after acute acoustic trauma. Copyright © 2012 IMSS. All rights reserved.
The effect of round window reinforcement on human hearing
NASA Astrophysics Data System (ADS)
Guan, Xiying; Cheng, Y. Song; Galaiya, Deepa; Nakajima, Hideko H.
2018-05-01
The compliant round window (RW) allows volume velocity to flow within the incompressible fluid of the cochlea as the oval window vibrates during sound stimulation. Recently, surgically stiffened RW is emerging as a treatment for various conditions such as superior canal dehiscence and hyperacusis. However, we lack the basic understanding of how reinforcing the RW affects sound transmission in the ear. The aim of this study is to clarify the effect of RW reinforcement on hearing. To study the effect of RW reinforcement with tissue and adhesive, we measured intracochlear pressures in scala vestibuli (Psv) and scala tympani (Pst) at the cochlear base together with stapes velocity in response to sound at the ear canal. The cochlear input drive (Pdiff = Psv - Pst, an estimate of hearing) was determined before and after RW reinforcement in a fresh human cadaveric ear. Results show that increasing the RW stiffness by reinforcement can affect the cochlear input drive in unexpected ways. Below 200 Hz, RW reinforcement resulted in reduced stapes motion, however an increase in cochlear drive, consistent with increase in hearing. At 200-1000 Hz, the hearing and stapes motion both were slightly decreased. Reinforcing the RW had no effect above 1 kHz. To understand the cochlear mechanical effects of RW reinforcement, we used a lumped-element model that simulated our findings.
Chang, Hao; Telang, Ravindra S; Sreebhavan, Sreevalsan; Tingle, Malcolm; Thorne, Peter R; Vlajkovic, Srdjan M
2017-01-01
Noise-induced hearing loss (NIHL) is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A 1 adenosine receptor agonist adenosine amine congener (ADAC) has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous) administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise.
Blood flow-independent accumulation of cisplatin in the guinea pig cochlea.
Miettinen, S; Laurell, G; Andersson, A; Johansson, R; Laurikainen, E
1997-01-01
Considerable interindividual variability in the ototoxic effect of cisplatin has become the unpredictable dose-limiting factor in its use as curative as well as palliative therapy. The drug accumulates in highly vascular areas in the cochlea, causing dose-related hair cell loss. The purpose of this study was to assess blood flow-dependent aspects of cisplatin absorption in the cochlea in order to better understand factors that may influence cisplatin-induced ototoxicity. The effect of reduced cochlear blood flow on the ototoxic action of cisplatin was studied in guinea pigs. Before cisplatin administration the cochlear vasculature in each animal was unilaterally pre-constricted, by the application of 2% epinephrine to the round window. A 20-30% reduction in cochlear blood flow, assessed by laser Doppler flowmetry, was maintained before and after intravenous infusion of 0.1% cisplatin. Cisplatin infusion affected cochlear blood flow but not vessel conductivity. The cochlear blood flow decrease, maintained by local epinephrine application to the round window during cisplatin infusion, did not alter the cisplatin-induced hearing loss. In addition, the concentration of free cisplatin in scala tympani perilymph did not differ between epinephrine-treated and non-treated ears. Our results indicate that cisplatin transport into the cochlea is not an energy-dependent process in the lateral wall vasculature.
Sreebhavan, Sreevalsan; Thorne, Peter R.
2017-01-01
Noise-induced hearing loss (NIHL) is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A1 adenosine receptor agonist adenosine amine congener (ADAC) has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous) administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise. PMID:28194422
Ototoxicity of salicylate, nonsteroidal antiinflammatory drugs, and quinine.
Jung, T T; Rhee, C K; Lee, C S; Park, Y S; Choi, D C
1993-10-01
Salicylates and most NSAIDS in high doses cause mild to moderate temporary hearing loss, either flat or greater in the high frequencies. Hearing loss is accompanied by tinnitus and suprathreshold changes. Salicylates may or may not exacerbate hearing loss and cochlear damage induced by noise. The mechanism of salicylate ototoxicity seems to be multifactorial. Morphologic studies suggest that no permanent cochlear damage occurs with salicylate ototoxicity. Electrophysiologic, morphologic, and in vitro data conclusively demonstrate that salicylate affects outer hair cells. In addition, salicylates appear to decrease cochlear blood flow. Salicylates and NSAIDs inhibit PG-forming cyclooxygenase, and recent studies suggest that abnormal levels of arachidonic acid metabolites consisting of decreased PGs and increased LTs may mediate salicylate ototoxicity. As with salicylate, quinine ototoxicity appears to be multifactorial in origin. The mechanism includes vasoconstriction and decreases in cochlear blood flow, as measured by laser Doppler flowmetry, motion photographic studies, and histologic studies. Reversible alterations of outer hair cells also appear to play an important role, as demonstrated by histology, electron microscopy, isolated hair cell studies, and cochlear potential evaluations. Unlike with salicylate, however, the role of prostaglandins in quinine ototoxicity has not been clearly demonstrated. Also, one of quinine's principal actions, antagonism of calcium-dependent potassium channels, has yet to be investigated for its potential role in ototoxicity.
Ear asymmetries in middle-ear, cochlear, and brainstem responses in human infants
Keefe, Douglas H.; Gorga, Michael P.; Jesteadt, Walt; Smith, Lynette M.
2008-01-01
In 2004, Sininger and Cone-Wesson examined asymmetries in the signal-to-noise ratio (SNR) of otoacoustic emissions (OAE) in infants, reporting that distortion-product (DP)OAE SNR was larger in the left ear, whereas transient-evoked (TE)OAE SNR was larger in the right. They proposed that cochlear and brainstem asymmetries facilitate development of brain-hemispheric specialization for sound processing. Similarly, in 2006 Sininger and Cone-Wesson described ear asymmetries mainly favoring the right ear in infant auditory brainstem responses (ABRs). The present study analyzed 2640 infant responses to further explore these effects. Ear differences in OAE SNR, signal, and noise were evaluated separately and across frequencies (1.5, 2, 3, and 4 kHz), and ABR asymmetries were compared with cochlear asymmetries. Analyses of ear-canal reflectance and admittance showed that asymmetries in middle-ear functioning did not explain cochlear and brainstem asymmetries. Current results are consistent with earlier studies showing right-ear dominance for TEOAE and ABR. Noise levels were higher in the right ear for OAEs and ABRs, causing ear asymmetries in SNR to differ from those in signal level. No left-ear dominance for DPOAE signal was observed. These results do not support a theory that ear asymmetries in cochlear processing mimic hemispheric brain specialization for auditory processing. PMID:18345839
Productivity of lexical categories in French-speaking children with cochlear implants.
Le Normand, M-T; Ouellet, C; Cohen, H
2003-11-01
The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.
Jin, Yong-Ming; Godfrey, Donald A; Sun, Yizhe
2005-07-01
Using microdissection and quantitative microassay, choline acetyltransferase (ChAT) activity was mapped in the cochlear nucleus (CN) and in the source nuclei of the olivocochlear bundle, the lateral superior olive and ventral nucleus of the trapezoid body. In control rats, gradients of ChAT activity were found within the major subdivisions of the CN and in the lateral superior olive. These gradients correlated with the known tonotopic organizations, with higher activities corresponding to locations representing higher sound frequencies. No gradient was found in the ventral nucleus of the trapezoid body. In rats surviving 7 days or 1 or 2 months after cochlear ablation, ChAT activity was increased 1 month after ablation in the anteroventral CN by 30-50% in most parts of the lesion-side and by 40% in the contralateral ventromedial part. ChAT activity in the lesion-side posteroventral CN was increased by approximately 40-50% at all survival times. Little change was found in the dorsal CN. Decreases of ChAT activity were also found ipsilaterally in the lateral superior olive and bilaterally in the ventral nucleus of the trapezoid body. Our results suggest that cholinergic neurons are involved in plasticity within the CN and superior olive following cochlear lesions. Copyright 2005 Wiley-Liss, Inc.
Shah, Parth V; Kozin, Elliott D; Kaplan, Alyson B; Lee, Daniel J
2016-01-01
The auditory brainstem implant (ABI) is a neuroprosthetic device that provides sound sensations to individuals with profound hearing loss who are not candidates for a cochlear implant (CI) because of anatomic constraints. Herein we describe the ABI for family physicians. PubMed was searched to identify articles relevant to the ABI, as well as articles that contain outcomes data for pediatric patients (age <18 years) who have undergone ABI surgery. The ABI was originally developed for patients with neurofibromatosis type 2 (NF2) who become deaf from bilateral vestibular schwannomas. Over the past decade, indications for an ABI have expanded to adult patients without tumors (without NF2) who cannot receive a CI and children with no cochlea or cochlear nerve. Outcomes among NF2 ABI users are modest compared to cochlear implant patients, but recent studies from Europe suggest that some non-tumor adult and pediatric ABI users achieve speech perception. The ABI is a reasonable surgical option for children with profound hearing loss due to severe cochlear or cochlear nerve deformities. Continued prospective data collection from several clinical trials in the U.S. will provide greater understanding on long term outcomes that focus on speech intelligibility. © Copyright 2016 by the American Board of Family Medicine.
Quittner, Alexandra L.; Cejas, Ivette; Wang, Nae-Yuh; Niparko, John K.; Barker, David H.
2016-01-01
In the largest, longitudinal study of young, deaf children before and three years after cochlear implantation, we compared symbolic play and novel noun learning to age-matched hearing peers. Participants were 180 children from six cochlear implant centers and 96 hearing children. Symbolic play was measured during five minutes of videotaped, structured solitary play. Play was coded as "symbolic" if the child used substitution (e.g., a wooden block as a bed). Novel noun learning was measured in 10 trials using a novel object and a distractor. Cochlear implant vs. normal hearing children were delayed in their use of symbolic play, however, those implanted before vs. after age two performed significantly better. Children with cochlear implants were also delayed in novel noun learning (median delay 1.54 years), with minimal evidence of catch-up growth. Quality of parent-child interactions was positively related to performance on the novel noun learning, but not symbolic play task. Early implantation was beneficial for both achievement of symbolic play and novel noun learning. Further, maternal sensitivity and linguistic stimulation by parents positively affected noun learning skills, although children with cochlear implants still lagged in comparison to hearing peers. PMID:27228032
Vocal singing by prelingually-deafened children with cochlear implants.
Xu, Li; Zhou, Ning; Chen, Xiuwu; Li, Yongxin; Schultz, Heather M; Zhao, Xiaoyan; Han, Demin
2009-09-01
The coarse pitch information in cochlear implants might hinder the development of singing in prelingually-deafened pediatric users. In the present study, seven prelingually-deafened children with cochlear implants (5.4-12.3 years old) sang one song that was the most familiar to him or her. The control group consisted of 14 normal-hearing children (4.1-8.0 years old). The fundamental frequencies (F0) of each note in the recorded songs were extracted. The following five metrics were computed based on the reference music scores: (1) F0 contour direction of the adjacent notes, (2) F0 compression ratio of the entire song, (3) mean deviation of the normalized F0 across the notes, (4) mean deviation of the pitch intervals, and (5) standard deviation of the note duration differences. Children with cochlear implants showed significantly poorer performance in the pitch-based assessments than the normal-hearing children. No significant differences were seen between the two groups in the rhythm-based measure. Prelingually-deafened children with cochlear implants have significant deficits in singing due to their inability to manipulate pitch in the correct directions and to produce accurate pitch height. Future studies with a large sample size are warranted in order to account for the large variability in singing performance.
Effect of cochlear implantation on middle ear function: A three-month prospective study.
Wasson, Joseph D; Campbell, Luke; Chambers, Scott; Hampson, Amy; Briggs, Robert J S; O'Leary, Stephen J
2018-05-01
To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. Prospective cohort study. Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. 4. Laryngoscope, 128:1207-1212, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Measurement of cochlear length using the 'A' value for cochlea basal diameter: A feasibility study.
Deep, Nicholas L; Howard, Brittany E; Holbert, Sarah O; Hoxworth, Joseph M; Barrs, David M
2017-07-01
To determine whether the cochlea basal diameter (A value) measurement can be consistently and precisely obtained from high-resolution temporal bone imaging for use in cochlear length estimation. A feasibility study at a tertiary referral center was performed using the temporal bone CTs of 40 consecutive patients. The distance from the round window to the lateral wall was measured for each cochlea by two independent reviewers, a neuroradiologist and an otolaryngologist. The interrater reliability was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Forty patients (19 males, 21 females) for a total of 80 cochleae were included. Interrater reliability on the same ear had a high level of agreement by both the ICC and the Bland-Altman plot. ICCs were 0.90 (95% CI: 0.82, 0.94) for the left ear and 0.96 (95% CI: 0.92, 0.98) for the right ear. Bland-Altman plot confirmed interrater reliability with all 96% of measurements falling within the 95% limits of agreement. Measurement between the round window and lateral cochlear wall can be consistently and reliably obtained from high-resolution temporal bone CT scans. Thus, it is feasible to utilize this method to estimate the cochlear length of patients undergoing cochlear implantation.
Aronoff, Justin M.; Freed, Daniel J.; Fisher, Laurel M.; Pal, Ivan; Soli, Sigfrid D.
2011-01-01
Objectives Cochlear implant microphones differ in placement, frequency response, and other characteristics such as whether they are directional. Although normal hearing individuals are often used as controls in studies examining cochlear implant users’ binaural benefits, the considerable differences across cochlear implant microphones make such comparisons potentially misleading. The goal of this study was to examine binaural benefits for speech perception in noise for normal hearing individuals using stimuli processed by head-related transfer functions (HRTFs) based on the different cochlear implant microphones. Design HRTFs were created for different cochlear implant microphones and used to test participants on the Hearing in Noise Test. Experiment 1 tested cochlear implant users and normal hearing individuals with HRTF-processed stimuli and with sound field testing to determine whether the HRTFs adequately simulated sound field testing. Experiment 2 determined the measurement error and performance-intensity function for the Hearing in Noise Test with normal hearing individuals listening to stimuli processed with the various HRTFs. Experiment 3 compared normal hearing listeners’ performance across HRTFs to determine how the HRTFs affected performance. Experiment 4 evaluated binaural benefits for normal hearing listeners using the various HRTFs, including ones that were modified to investigate the contributions of interaural time and level cues. Results The results indicated that the HRTFs adequately simulated sound field testing for the Hearing in Noise Test. They also demonstrated that the test-retest reliability and performance-intensity function were consistent across HRTFs, and that the measurement error for the test was 1.3 dB, with a change in signal-to-noise ratio of 1 dB reflecting a 10% change in intelligibility. There were significant differences in performance when using the various HRTFs, with particularly good thresholds for the HRTF based on the directional microphone when the speech and masker were spatially separated, emphasizing the importance of measuring binaural benefits separately for each HRTF. Evaluation of binaural benefits indicated that binaural squelch and spatial release from masking were found for all HRTFs and binaural summation was found for all but one HRTF, although binaural summation was less robust than the other types of binaural benefits. Additionally, the results indicated that neither interaural time nor level cues dominated binaural benefits for the normal hearing participants. Conclusions This study provides a means to measure the degree to which cochlear implant microphones affect acoustic hearing with respect to speech perception in noise. It also provides measures that can be used to evaluate the independent contributions of interaural time and level cues. These measures provide tools that can aid researchers in understanding and improving binaural benefits in acoustic hearing individuals listening via cochlear implant microphones. PMID:21412155
Use of Vaccines to Prevent Meningitis in Persons with Cochlear Implants
... candidates for cochlear implants. CDC also recommends pneumococcal polysaccharide vaccine (PPSV23) for people 2 years and older ... pneumococcal conjugate (PCV13) (Prevnar 13®) 23-valent pneumococcal polysaccharide (PPSV23) (Pneumovax®) Haemophilus influenzae type b conjugate (Hib) ( ...
[Hearing and balance in metabolic bone diseases].
Zatoński, Tomasz; Temporale, Hanna; Krecicki, Tomasz
2012-03-01
There are reports that hearing loss is one of the clinical manifestations of metabolic bone diseases. Demineralization can lead to a reduction in ossicular mass. Paget's disease can reveal loss of mineral density of the cochlear bone. Ear bone remodeling in osteoporosis is similar to the changes in otosclerosis. Moreover, osteoporosis, osteogenesis imperfecta and otosclerosis have a similar genetic mechanism. According to some researchers osteopenia and osteoporosis may well be associated with idiopathic benign positional vertigo (BPV). Dysfunction of the organ of hearing and balance in patients with renal insufficiency may be due to disturbances in calcium phosphate balance and renal osteodystrophy in the course of the disease. Proving the presence of hearing loss in patients with metabolic bone diseases may lead to determining the new indications for bone densitometry in some patients with hearing impairment. Furthermore, audiological examination in patients with osteoporosis may be important because of the impact of hearing loss on prognosis for patients with metabolic bone diseases.
Encoding and decoding amplitude-modulated cochlear implant stimuli—a point process analysis
Shea-Brown, Eric; Rubinstein, Jay T.
2010-01-01
Cochlear implant speech processors stimulate the auditory nerve by delivering amplitude-modulated electrical pulse trains to intracochlear electrodes. Studying how auditory nerve cells encode modulation information is of fundamental importance, therefore, to understanding cochlear implant function and improving speech perception in cochlear implant users. In this paper, we analyze simulated responses of the auditory nerve to amplitude-modulated cochlear implant stimuli using a point process model. First, we quantify the information encoded in the spike trains by testing an ideal observer’s ability to detect amplitude modulation in a two-alternative forced-choice task. We vary the amount of information available to the observer to probe how spike timing and averaged firing rate encode modulation. Second, we construct a neural decoding method that predicts several qualitative trends observed in psychophysical tests of amplitude modulation detection in cochlear implant listeners. We find that modulation information is primarily available in the sequence of spike times. The performance of an ideal observer, however, is inconsistent with observed trends in psychophysical data. Using a neural decoding method that jitters spike times to degrade its temporal resolution and then computes a common measure of phase locking from spike trains of a heterogeneous population of model nerve cells, we predict the correct qualitative dependence of modulation detection thresholds on modulation frequency and stimulus level. The decoder does not predict the observed loss of modulation sensitivity at high carrier pulse rates, but this framework can be applied to future models that better represent auditory nerve responses to high carrier pulse rate stimuli. The supplemental material of this article contains the article’s data in an active, re-usable format. PMID:20177761
Implications of Minimizing Trauma During Conventional Cochlear Implantation
Carlson, Matthew L.; Driscoll, Colin L. W.; Gifford, René H.; Service, Geoffrey J.; Tombers, Nicole M.; Hughes-Borst, Becky J.; Neff, Brian A.; Beatty, Charles W.
2014-01-01
Objective To describe the relationship between implantation-associated trauma and postoperative speech perception scores among adult and pediatric patients undergoing cochlear implantation using conventional length electrodes and minimally traumatic surgical techniques. Study Design Retrospective chart review (2002–2010). Setting Tertiary academic referral center. Patients All subjects with significant preoperative low-frequency hearing (≤70 dB HL at 250 Hz) who underwent cochlear implantation with a newer generation implant electrode (Nucleus Contour Advance, Advanced Bionics HR90K [1J and Helix], and Med El Sonata standard H array) were reviewed. Intervention(s) Preimplant and postimplant audiometric thresholds and speech recognition scores were recorded using the electronic medical record. Main Outcome Measure(s) Postimplantation pure tone threshold shifts were used as a surrogate measure for extent of intracochlear injury and correlated with postoperative speech perception scores. Results Between 2002 and 2010, 703 cochlear implant (CI) operations were performed. Data from 126 implants were included in the analysis. The mean preoperative low-frequency pure-tone average was 55.4 dB HL. Hearing preservation was observed in 55% of patients. Patients with hearing preservation were found to have significantly higher postoperative speech perception performance in the cochlear implantation-only condition than those who lost all residual hearing. Conclusion Conservation of acoustic hearing after conventional length cochlear implantation is unpredictable but remains a realistic goal. The combination of improved technology and refined surgical technique may allow for conservation of some residual hearing in more than 50% of patients. Germane to the conventional length CI recipient with substantial hearing loss, minimizing trauma allows for improved speech perception in the electric condition. These findings support the use of minimally traumatic techniques in all CI recipients, even those destined for electric-only stimulation. PMID:21659922
Lohuis, P J; Börjesson, P K; Klis, S F; Smoorenburg, G F
2000-05-01
Circulating adrenal hormones affect strial function. Removal of endogenous levels of adrenal steroids by bilateral adrenalectomy (ADX) in rats causes a decrease of Na(+)/K(+)-ATPase activity in the cochlear lateral wall [Rarey et al., 1989. Arch. Otolaryngol. Head Neck Surg. 115, 817-821] and a decrease of the volume of the marginal cells in the stria vascularis [Lohuis et al., 1990. Acta Otolaryngol. (Stockh.) 110, 348-356]. To study further the effect of absence of circulating adrenocorticosteroids on cochlear function, 18 male Long Evans rats underwent either an ADX or a SHAM operation. Electrocochleography was performed 1 week after surgery for tone bursts in a frequency range of 1-16 kHz. Thereafter, the cochleas were harvested and examined histologically. No significant changes in the amplitude growth curves of the summating potential (SP), the compound action potential (CAP) and the cochlear microphonics (CM) were detected after ADX. However, visually, there appeared to be a decrease of endolymphatic volume (tentatively called imdrops). Reissner's membrane (RM) extended less into scala vestibuli in ADX animals than in SHAM-operated animals. The ratio between the length of RM and the straight distance between the medial and lateral attachment points of RM were used as an objective measure to quantify this effect in each sub-apical half turn of the cochlea. The decrease in length of RM was statistically significant. Thus, circulating adrenal hormones appear to be necessary for normal cochlear fluid homeostasis. Absence of one or more of these hormones leads to shrinkage of the scala media (imdrops). However, the absence of adrenal hormones does not affect the gross cochlear potentials. Apparently, the cochlea is capable of compensating for the absence of circulating adrenal hormones to sustain the conditions necessary for proper cochlear transduction.
The Development of Auditory Perception in Children Following Auditory Brainstem Implantation
Colletti, Liliana; Shannon, Robert V.; Colletti, Vittorio
2014-01-01
Auditory brainstem implants (ABI) can provide useful auditory perception and language development in deaf children who are not able to use a cochlear implant (CI). We prospectively followed-up a consecutive group of 64 deaf children up to 12 years following ABI implantation. The etiology of deafness in these children was: cochlear nerve aplasia in 49, auditory neuropathy in 1, cochlear malformations in 8, bilateral cochlear post-meningitic ossification in 3, NF2 in 2, and bilateral cochlear fractures due to a head injury in 1. Thirty five children had other congenital non-auditory disabilities. Twenty two children had previous CIs with no benefit. Fifty eight children were fitted with the Cochlear 24 ABI device and six with the MedEl ABI device and all children followed the same rehabilitation program. Auditory perceptual abilities were evaluated on the Categories of Auditory Performance (CAP) scale. No child was lost to follow-up and there were no exclusions from the study. All children showed significant improvement in auditory perception with implant experience. Seven children (11%) were able to achieve the highest score on the CAP test; they were able to converse on the telephone within 3 years of implantation. Twenty children (31.3%) achieved open set speech recognition (CAP score of 5 or greater) and 30 (46.9%) achieved a CAP level of 4 or greater. Of the 29 children without non-auditory disabilities, 18 (62%) achieved a CAP score of 5 or greater with the ABI. All children showed continued improvements in auditory skills over time. The long-term results of ABI implantation reveal significant auditory benefit in most children, and open set auditory recognition in many. PMID:25377987
Padilla, Monica; Landsberger, David M
2016-03-01
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.
Padilla, Monica; Landsberger, David M.
2016-01-01
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. PMID:26778546
The Impact of Cochlear Implant in the Oral Language of Children with Congenital Deafness.
Ramos, Daniela; Jorge, João Xavier; Teixeira, António; Ribeiro, Carlos; Paiva, António
2015-01-01
Children with severe to profound sensorineural deafness can acquire vocabulary and syntactic structures to communicate by oral language, after cochlear implant. Identify the linguistic skills of children with cochlear implant. Eighteen children of both gender, between 9 and 10 years, with congenital bilateral deafness, using cochlear implant, were studied. The evaluation instrument used was Observation Chart of Language-School Level. The results were compared with standard of normal-hearing children with the same hearing age. The scores registered in the linguistics structures studied, comparing implanted children and standard, was: phonology, 29.44 ± 8.4 vs. 29.68 ± 5.90, p = 0.91; semantics, 18.55 ± 8.89 vs. 19.20 ± 4.85, p = 0.76; morpho-syntax 21.89 ± 12.85 vs. 26.35 ± 10.36, p = 0.159. Regarding the tests of semantics, there was no significant difference. Concerning the tests of morpho-syntactic structure, the difference was significant in the derivation of words, 2.83 ± 2.81 vs. 4.65 ± 1.64, p = 0.014. In the phonology, a significant difference was found comparing implanted children and standard, in the discrimination of pseudo words, 6.6 ± 2.8 vs. 8.37 ± 2.32, p = 0.023. However, in syllabic segmentation, implanted children had a mean score 8.56 ± 1.6 significantly higher than standard, 5.9 ± 1.58, p < 0.001. The similarity of the scores obtained by children with cochlear implants with the standard, in the language components studied confirms that cochlear implant promotes the development of oral verbal language in children with congenital deafness. Implanted children had acquired language skills similar to normal-hearing children with the same hearing age.
Barriers to pediatric cochlear implantation: A parental survey.
Yang, Charles Q; Reilly, Brian K; Preciado, Diego A
2018-01-01
This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.
Rowe, David; Chambers, Scott; Hampson, Amy; Eastwood, Hayden; Campbell, Luke; O'Leary, Stephen
2016-03-01
Cochlear implant recipients show improved speech perception and music appreciation when residual acoustic hearing is combined with the cochlear implant. However, up to one third of patients lose their pre-operative residual hearing weeks to months after implantation, for reasons that are not well understood. This study tested whether this "delayed" hearing loss was influenced by the route of electrode array insertion and/or position of the electrode array within scala tympani in a guinea pig model of cochlear implantation. Five treatment groups were monitored over 12 weeks: (1) round window implant; (2) round window incised with no implant; (3) cochleostomy with medially-oriented implant; (4) cochleostomy with laterally-oriented implant; and (5) cochleostomy with no implant. Hearing was measured at selected time points by the auditory brainstem response. Cochlear condition was assessed histologically, with cochleae three-dimensionally reconstructed to plot electrode paths and estimate tissue response. Electrode array trajectories matched their intended paths. Arrays inserted via the round window were situated nearer to the basilar membrane and organ of Corti over the majority of their intrascalar path compared with arrays inserted via cochleostomy. Round window interventions exhibited delayed, low frequency hearing loss that was not seen after cochleostomy. This hearing loss appeared unrelated to the extent of tissue reaction or injury within scala tympani, although round window insertion was histologically the most traumatic mode of implantation. We speculate that delayed hearing loss was related not to the electrode position as postulated, but rather to the muscle graft used to seal the round window post-intervention, by altering cochlear mechanics via round window fibrosis. Copyright © 2015 Elsevier B.V. All rights reserved.