Cochlear microphonic broad tuning curves
NASA Astrophysics Data System (ADS)
Ayat, Mohammad; Teal, Paul D.; Searchfield, Grant D.; Razali, Najwani
2015-12-01
It is known that the cochlear microphonic voltage exhibits much broader tuning than does the basilar membrane motion. The most commonly used explanation for this is that when an electrode is inserted at a particular point inside the scala media, the microphonic potentials of neighbouring hair cells have different phases, leading to cancelation at the electrodes location. In situ recording of functioning outer hair cells (OHCs) for investigating this hypothesis is exceptionally difficult. Therefore, to investigate the discrepancy between the tuning curves of the basilar membrane and those of the cochlear microphonic, and the effect of phase cancellation of adjacent hair cells on the broadness of the cochlear microphonic tuning curves, we use an electromechanical model of the cochlea to devise an experiment. We explore the effect of adjacent hair cells (i.e., longitudinal phase cancellation) on the broadness of the cochlear microphonic tuning curves in different locations. The results of the experiment indicate that active longitudinal coupling (i.e., coupling with active adjacent outer hair cells) only slightly changes the broadness of the CM tuning curves. The results also demonstrate that there is a π phase difference between the potentials produced by the hair bundle and the soma near the place associated with the characteristic frequency based on place-frequency maps (i.e., the best place). We suggest that the transversal phase cancellation (caused by the phase difference between the hair bundle and the soma) plays a far more important role than longitudinal phase cancellation in the broadness of the cochlear microphonic tuning curves. Moreover, by increasing the modelled longitudinal resistance resulting the cochlear microphonic curves exhibiting sharper tuning. The results of the simulations suggest that the passive network of the organ of Corti determines the phase difference between the hair bundle and soma, and hence determines the sharpness of the cochlear microphonic tuning curves.
The benefits of remote microphone technology for adults with cochlear implants.
Fitzpatrick, Elizabeth M; Séguin, Christiane; Schramm, David R; Armstrong, Shelly; Chénier, Josée
2009-10-01
Cochlear implantation has become a standard practice for adults with severe to profound hearing loss who demonstrate limited benefit from hearing aids. Despite the substantial auditory benefits provided by cochlear implants, many adults experience difficulty understanding speech in noisy environments and in other challenging listening conditions such as television. Remote microphone technology may provide some benefit in these situations; however, little is known about whether these systems are effective in improving speech understanding in difficult acoustic environments for this population. This study was undertaken with adult cochlear implant recipients to assess the potential benefits of remote microphone technology. The objectives were to examine the measurable and perceived benefit of remote microphone devices during television viewing and to assess the benefits of a frequency-modulated system for speech understanding in noise. Fifteen adult unilateral cochlear implant users were fit with remote microphone devices in a clinical environment. The study used a combination of direct measurements and patient perceptions to assess speech understanding with and without remote microphone technology. The direct measures involved a within-subject repeated-measures design. Direct measures of patients' speech understanding during television viewing were collected using their cochlear implant alone and with their implant device coupled to an assistive listening device. Questionnaires were administered to document patients' perceptions of benefits during the television-listening tasks. Speech recognition tests of open-set sentences in noise with and without remote microphone technology were also administered. Participants showed improved speech understanding for television listening when using remote microphone devices coupled to their cochlear implant compared with a cochlear implant alone. This benefit was documented both when listening to news and talk show recordings. Questionnaire results also showed statistically significant differences between listening with a cochlear implant alone and listening with a remote microphone device. Participants judged that remote microphone technology provided them with better comprehension, more confidence, and greater ease of listening. Use of a frequency-modulated system coupled to a cochlear implant also showed significant improvement over a cochlear implant alone for open-set sentence recognition in +10 and +5 dB signal to noise ratios. Benefits were measured during remote microphone use in focused-listening situations in a clinical setting, for both television viewing and speech understanding in noise in the audiometric sound suite. The results suggest that adult cochlear implant users should be counseled regarding the potential for enhanced speech understanding in difficult listening environments through the use of remote microphone technology.
[Value of the study of cochlear microphonic recordings in deep and severe deafness].
Moatti, L; Busquet, D; Cotin, G
1983-01-01
A study was conducted to assess the contribution of cochlear microphonic potential recordings during electrophysiologic audiometry examinations. Amplitude of microphonic recordings were correlated with the degree of deafness, its etiology, and the prosthetic prognosis in 38 electrocochleographic examinations. Preliminary results are analyzed.
Noise alters hair-bundle mechanics at the cochlear apex
NASA Astrophysics Data System (ADS)
Strimbu, C. Elliott; Fridberger, Anders
2015-12-01
Exposure to loud sounds can lead to both permanent and short term changes in auditory sensitivity. Permanent hearing loss is often associated with gross changes in cochlear morphology including the loss of hair cells and auditory nerve fibers while the mechanisms of short term threshold shifts are much less well understood and may vary at different locations across the cochlea. Previous reports suggest that exposure to loud sounds leads to a decrease in the cochlear microphonic potential and in the stiffness of the organ of Corti. Because the cochlear microphonic reflects changes in the membrane potential of the hair cells, this suggests that hair-bundle motion should be reversibly altered following exposure to loud sounds. Using an in vitro preparation of the guinea pig temporal bone we investigate changes in the micro-mechanical response near the cochlear apex following a brief (up to 10 - 20 minutes) exposure to loud (˜ 120 dB) tones near the best frequency at this location. We use time-resolved confocal imaging to record the motion of outer hair cell bundles before and after acoustic overstimulation. We have also recorded larger-scale structural views of the organ of Corti before and after exposure to the loud sound. Conventional electrophysiological techniques are used measure the cochlear microphonic potential. As has been previously reported, following acoustic overexposure the cochlear microphonic declines in value and typically recovers on the order of 30 - 60 minutes. Hair-bundle trajectories are affected following the loud sound and typically recover on a somewhat faster time scale than the microphonic potential, although the results vary considerably across preparations. Preliminary results also suggest reversible changes in the hair cell's resting potential following the loud sound.
Jenkins, Herman A; Uhler, Kristin
2012-01-01
To compare the speech understanding abilities of cochlear implant listeners using 2 microphone technologies, the Otologics fully implantable Carina and the Cochlear Freedom microphones. Feasibility study using direct comparison of the 2 microphones, nonrandomized and nonblinded within case studies. Tertiary referral center hospital outpatient clinic. Four subjects with greater than 1 year of unilateral listening experience with the Freedom Cochlear Implant and a CNC word score higher than 40%. A Carina microphone coupled to a percutaneous plug was implanted on the ipsilateral side of the cochlear implant. Two months were allowed for healing before connecting to the Carina microphone. The percutaneous plug was connected to a body worn external processor with output leads inserted into the auxiliary port of the Freedom processor. Subjects were instructed to use each of the 2 microphones for half of their daily implant use. Aided pure tone thresholds, consonant-nucleus-consonant (CNC), Bamford-Kowel-Bench Speech in Noise test (BKN-SIN), and Abbreviated Profile of Hearing Aid Benefit. All subjects had sound perceptions using both microphones. The loudness and quality of the sound was judged to be poorer with the Carina in the first 2 subjects. The latter 2 demonstrated essential equivalence in the second two listeners, with the exception of the Abbreviated Profile of Hearing Aid Benefit reporting greater percentage of problems for the Carina in the background noise situation for subject 0011-003PP. CNC word scores were better with the Freedom than the Carina in all 4 subjects. The latter 2 showed improved speech perception abilities with the Carina, compared with the first 2. The BKB-SIN showed consistently better results with the Freedom in noise. Early observations indicate that it is potentially feasible to use the fully implanted Carina microphone with the Freedom Cochlear Implant. The authors would anticipate that outcomes would improve as more knowledge is gained in signal processing and with the fabrication of an integrated device.
Analysis of the cochlear microphonic to a low-frequency tone embedded in filtered noise
Chertoff, Mark E.; Earl, Brian R.; Diaz, Francisco J.; Sorensen, Janna L.
2012-01-01
The cochlear microphonic was recorded in response to a 733 Hz tone embedded in noise that was high-pass filtered at 25 different frequencies. The amplitude of the cochlear microphonic increased as the high-pass cutoff frequency of the noise increased. The amplitude growth for a 60 dB SPL tone was steeper and saturated sooner than that of an 80 dB SPL tone. The growth for both signal levels, however, was not entirely cumulative with plateaus occurring at about 4 and 7 mm from the apex. A phenomenological model of the electrical potential in the cochlea that included a hair cell probability function and spiral geometry of the cochlea could account for both the slope of the growth functions and the plateau regions. This suggests that with high-pass-filtered noise, the cochlear microphonic recorded at the round window comes from the electric field generated at the source directed towards the electrode and not down the longitudinal axis of the cochlea. PMID:23145616
Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.
Chung, King; McKibben, Nicholas
2011-10-01
Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before and after the pre-emphasis filter, were analyzed. Correlation coefficients between speech recognition scores and crest factors of wind noise before and after pre-emphasis filtering were also calculated. Listeners obtained higher scores using the omnidirectional than the directional microphone mode at 13.5 m/sec, but they obtained similar speech recognition scores for the two microphone modes at 4.5 m/sec. Higher correlation coefficients were obtained between speech recognition scores and crest factors of wind noise after pre-emphasis filtering rather than before filtering. Cochlear implant users would benefit from both directional and omnidirectional microphones to reduce far-field background noise and near-field wind noise. Automatic microphone switching algorithms can be more effective if the incoming signal were analyzed after pre-emphasis filters for microphone switching decisions. American Academy of Audiology.
An Electromechanical Model for the Cochlear Microphonic
NASA Astrophysics Data System (ADS)
Teal, Paul D.; Lineton, Ben; Elliott, Stephen J.
2011-11-01
The first of the many electrical signals generated in the ear, nerves and brain as a response to a sound incident on the ear is the cochlear microphonic (CM). The CM is generated by the hair cells of the cochlea, primarily the outer hairs cells. The potentials of this signal are a nonlinear filtered version of the acoustic pressure at the tympanic membrane. The CM signal has been used very little in recent years for clinical audiology and audiological research. This is because of uncertainty in interpreting the CM signal as a diagnostic measure, and also because of the difficulty of obtaining the signal, which has usually required the use of a transtympanic electrode. There are however, several potential clinical and research applications for acquisition of the CM. To promote understanding of the CM, and potential clinical application, a model is presented which can account for the generation of the cochlear microphonic signal. The model incorporates micro-mechanical and macro-mechanical aspects of previously published models of the basilar membrane and reticular lamina, as well as cochlear fluid mechanics, piezoelectric activity and capacitance of the outer hair cells. It also models the electrical coupling of signals along the scalae.
Aronoff, Justin M.; Freed, Daniel J.; Fisher, Laurel M.; Pal, Ivan; Soli, Sigfrid D.
2011-01-01
Objectives Cochlear implant microphones differ in placement, frequency response, and other characteristics such as whether they are directional. Although normal hearing individuals are often used as controls in studies examining cochlear implant users’ binaural benefits, the considerable differences across cochlear implant microphones make such comparisons potentially misleading. The goal of this study was to examine binaural benefits for speech perception in noise for normal hearing individuals using stimuli processed by head-related transfer functions (HRTFs) based on the different cochlear implant microphones. Design HRTFs were created for different cochlear implant microphones and used to test participants on the Hearing in Noise Test. Experiment 1 tested cochlear implant users and normal hearing individuals with HRTF-processed stimuli and with sound field testing to determine whether the HRTFs adequately simulated sound field testing. Experiment 2 determined the measurement error and performance-intensity function for the Hearing in Noise Test with normal hearing individuals listening to stimuli processed with the various HRTFs. Experiment 3 compared normal hearing listeners’ performance across HRTFs to determine how the HRTFs affected performance. Experiment 4 evaluated binaural benefits for normal hearing listeners using the various HRTFs, including ones that were modified to investigate the contributions of interaural time and level cues. Results The results indicated that the HRTFs adequately simulated sound field testing for the Hearing in Noise Test. They also demonstrated that the test-retest reliability and performance-intensity function were consistent across HRTFs, and that the measurement error for the test was 1.3 dB, with a change in signal-to-noise ratio of 1 dB reflecting a 10% change in intelligibility. There were significant differences in performance when using the various HRTFs, with particularly good thresholds for the HRTF based on the directional microphone when the speech and masker were spatially separated, emphasizing the importance of measuring binaural benefits separately for each HRTF. Evaluation of binaural benefits indicated that binaural squelch and spatial release from masking were found for all HRTFs and binaural summation was found for all but one HRTF, although binaural summation was less robust than the other types of binaural benefits. Additionally, the results indicated that neither interaural time nor level cues dominated binaural benefits for the normal hearing participants. Conclusions This study provides a means to measure the degree to which cochlear implant microphones affect acoustic hearing with respect to speech perception in noise. It also provides measures that can be used to evaluate the independent contributions of interaural time and level cues. These measures provide tools that can aid researchers in understanding and improving binaural benefits in acoustic hearing individuals listening via cochlear implant microphones. PMID:21412155
Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants
Azimi, Behnam; Hu, Yi; Friedland, David R.
2012-01-01
To restore hearing sensation, cochlear implants deliver electrical pulses to the auditory nerve by relying on sophisticated signal processing algorithms that convert acoustic inputs to electrical stimuli. Although individuals fitted with cochlear implants perform well in quiet, in the presence of background noise, the speech intelligibility of cochlear implant listeners is more susceptible to background noise than that of normal hearing listeners. Traditionally, to increase performance in noise, single-microphone noise reduction strategies have been used. More recently, a number of approaches have suggested that speech intelligibility in noise can be improved further by making use of two or more microphones, instead. Processing strategies based on multiple microphones can better exploit the spatial diversity of speech and noise because such strategies rely mostly on spatial information about the relative position of competing sound sources. In this article, we identify and elucidate the most significant theoretical aspects that underpin single- and multi-microphone noise reduction strategies for cochlear implants. More analytically, we focus on strategies of both types that have been shown to be promising for use in current-generation implant devices. We present data from past and more recent studies, and furthermore we outline the direction that future research in the area of noise reduction for cochlear implants could follow. PMID:22923425
Park, Steve; Guan, Xiying; Kim, Youngwan; Creighton, Francis Pete X; Wei, Eric; Kymissis, Ioannis John; Nakajima, Hideko Heidi; Olson, Elizabeth S
2018-01-01
We report the fabrication and characterization of a prototype polyvinylidene fluoride polymer-based implantable microphone for detecting sound inside gerbil and human cochleae. With the current configuration and amplification, the signal-to-noise ratios were sufficiently high for normally occurring sound pressures and frequencies (ear canal pressures >50-60 dB SPL and 0.1-10 kHz), though 10 to 20 dB poorer than for some hearing aid microphones. These results demonstrate the feasibility of the prototype devices as implantable microphones for the development of totally implantable cochlear implants. For patients, this will improve sound reception by utilizing the outer ear and will improve the use of cochlear implants.
Guan, Xiying; Kim, Youngwan; Creighton, Francis (Pete) X.; Wei, Eric; Kymissis, Ioannis(John); Nakajima, Hideko Heidi; Olson, Elizabeth S.
2018-01-01
We report the fabrication and characterization of a prototype polyvinylidene fluoride polymer-based implantable microphone for detecting sound inside gerbil and human cochleae. With the current configuration and amplification, the signal-to-noise ratios were sufficiently high for normally occurring sound pressures and frequencies (ear canal pressures >50–60 dB SPL and 0.1–10 kHz), though 10 to 20 dB poorer than for some hearing aid microphones. These results demonstrate the feasibility of the prototype devices as implantable microphones for the development of totally implantable cochlear implants. For patients, this will improve sound reception by utilizing the outer ear and will improve the use of cochlear implants. PMID:29732950
Chung, King; Nelson, Lance; Teske, Melissa
2012-09-01
The purpose of this study was to investigate whether a multichannel adaptive directional microphone and a modulation-based noise reduction algorithm could enhance cochlear implant performance in reverberant noise fields. A hearing aid was modified to output electrical signals (ePreprocessor) and a cochlear implant speech processor was modified to receive electrical signals (eProcessor). The ePreprocessor was programmed to flat frequency response and linear amplification. Cochlear implant listeners wore the ePreprocessor-eProcessor system in three reverberant noise fields: 1) one noise source with variable locations; 2) three noise sources with variable locations; and 3) eight evenly spaced noise sources from 0° to 360°. Listeners' speech recognition scores were tested when the ePreprocessor was programmed to omnidirectional microphone (OMNI), omnidirectional microphone plus noise reduction algorithm (OMNI + NR), and adaptive directional microphone plus noise reduction algorithm (ADM + NR). They were also tested with their own cochlear implant speech processor (CI_OMNI) in the three noise fields. Additionally, listeners rated overall sound quality preferences on recordings made in the noise fields. Results indicated that ADM+NR produced the highest speech recognition scores and the most preferable rating in all noise fields. Factors requiring attention in the hearing aid-cochlear implant integration process are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.
High-frequency hearing impairment assessed with cochlear microphonics.
Zhang, Ming
2012-09-01
Cochlear microphonic (CM) measurements may potentially become a supplementary approach to otoacoustic emission (OAE) measurements for assessing low-frequency cochlear functions in the clinic. The objective of this study was to investigate the measurement of CMs in subjects with high-frequency hearing loss. Currently, CMs can be measured using electrocochleography (ECochG or ECoG) techniques. Both CMs and OAEs are cochlear responses, while auditory brainstem responses (ABRs) are not. However, there are inherent limitations associated with OAE measurements such as acoustic noise, which can conceal low-frequency OAEs measured in the clinic. However, CM measurements may not have these limitations. CMs were measured in human subjects using an ear canal electrode. The CMs were compared between the high-frequency hearing loss group and the normal-hearing control group. Distortion product OAEs (DPOAEs) and audiogram were also measured. The DPOAE and audiogram measurements indicate that the subjects were correctly selected for the two groups. Low-frequency CM waveforms (CMWs) can be measured using ear canal electrodes in high-frequency hearing loss subjects. The difference in amplitudes of CMWs between the high-frequency hearing loss group and the normal-hearing group is insignificant at low frequencies but significant at high frequencies.
Helmstaedter, Victor; Lenarz, Thomas; Erfurt, Peter; Kral, Andrej; Baumhoff, Peter
2017-12-14
For the increasing number of cochlear implantations in subjects with residual hearing, hearing preservation, and thus the prevention of implantation trauma, is crucial. A method for monitoring the intracochlear position of a cochlear implant (CI) and early indication of imminent cochlear trauma would help to assist the surgeon to achieve this goal. The aim of this study was to evaluate the reliability of the different electric components recorded by an intracochlear electrocochleography (ECochG) as markers for the cochleotopic position of a CI. The measurements were made directly from the CI, combining intrasurgical diagnostics with the therapeutical use of the CI, thus, turning the CI into a "theragnostic probe." Intracochlear ECochGs were measured in 10 Dunkin Hartley guinea pigs of either sex, with normal auditory brainstem response thresholds. All subjects were fully implanted (4 to 5 mm) with a custom six contact CI. The ECochG was recorded simultaneously from all six contacts with monopolar configuration (retroauricular reference electrode). The gross ECochG signal was filtered off-line to separate three of its main components: compound action potential, cochlear microphonic, and summating potential (SP). Additionally, five cochleae were harvested and histologically processed to access the spatial position of the CI contacts. Both ECochG data and histological reconstructions of the electrode position were fitted with the Greenwood function to verify the reliability of the deduced cochleotopic position of the CI. SPs could be used as suitable markers for the frequency position of the recording electrode with an accuracy of ±1/4 octave in the functioning cochlea, verified by histology. Cochlear microphonics showed a dependency on electrode position but were less reliable as positional markers. Compound action potentials were not suitable for CI position information but were sensitive to "cochlear health" (e.g., insertion trauma). SPs directly recorded from the contacts of a CI during surgery can be used to access the intracochlear frequency position of the CI. Using SP monitoring, implantation may be stopped before penetrating functioning cochlear regions. If the technique was similarly effective in humans, it could prevent implantation trauma and increase hearing preservation during CI surgery. Diagnostic hardware and software for recording biological signals with a CI without filter limitations might be a valuable add-on to the portfolios of CI manufacturers.
Rekkedal, Ann Mette
2012-01-01
Hearing technology can play an essential part in the education of deaf and hard-of-hearing children in inclusive schools. Few studies have examined these children's experiences with this technology. This article explores factors pertaining to children's use of and attitudes toward hearing technologies, such as hearing aids, cochlear implants, teacher-worn microphones, and student-worn microphones. The study included 153 deaf and hard-of-hearing students. All students communicated orally and were in inclusive schools from grades 5-10. The results suggest that males view hearing technology more positively than do females. Having severe hearing loss also promoted positive attitudes toward hearing aids and cochlear implants, but not toward microphones. The students with positive self-descriptions tended to be more satisfied with hearing aids or cochlear implants than the students with negative self-descriptions. The main factors promoting the use of hearing aids were severe hearing loss, positive attitudes toward hearing aids, and the sound quality of hearing aids.
Wolfe, Jace; Morais, Mila; Schafer, Erin; Agrawal, Smita; Koch, Dawn
2015-05-01
Cochlear implant recipients often experience difficulty with understanding speech in the presence of noise. Cochlear implant manufacturers have developed sound processing algorithms designed to improve speech recognition in noise, and research has shown these technologies to be effective. Remote microphone technology utilizing adaptive, digital wireless radio transmission has also been shown to provide significant improvement in speech recognition in noise. There are no studies examining the potential improvement in speech recognition in noise when these two technologies are used simultaneously. The goal of this study was to evaluate the potential benefits and limitations associated with the simultaneous use of a sound processing algorithm designed to improve performance in noise (Advanced Bionics ClearVoice) and a remote microphone system that incorporates adaptive, digital wireless radio transmission (Phonak Roger). A two-by-two way repeated measures design was used to examine performance differences obtained without these technologies compared to the use of each technology separately as well as the simultaneous use of both technologies. Eleven Advanced Bionics (AB) cochlear implant recipients, ages 11 to 68 yr. AzBio sentence recognition was measured in quiet and in the presence of classroom noise ranging in level from 50 to 80 dBA in 5-dB steps. Performance was evaluated in four conditions: (1) No ClearVoice and no Roger, (2) ClearVoice enabled without the use of Roger, (3) ClearVoice disabled with Roger enabled, and (4) simultaneous use of ClearVoice and Roger. Speech recognition in quiet was better than speech recognition in noise for all conditions. Use of ClearVoice and Roger each provided significant improvement in speech recognition in noise. The best performance in noise was obtained with the simultaneous use of ClearVoice and Roger. ClearVoice and Roger technology each improves speech recognition in noise, particularly when used at the same time. Because ClearVoice does not degrade performance in quiet settings, clinicians should consider recommending ClearVoice for routine, full-time use for AB implant recipients. Roger should be used in all instances in which remote microphone technology may assist the user in understanding speech in the presence of noise. American Academy of Audiology.
He, Wenxuan; Porsov, Edward; Kemp, David; Nuttall, Alfred L.; Ren, Tianying
2012-01-01
Background It is commonly assumed that the cochlear microphonic potential (CM) recorded from the round window (RW) is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. Methodology/Principal Findings This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. Conclusions/Significance We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases. PMID:22470560
Resistance of Gerbil Auditory Function to Reversible Decrease in Cochlear Blood Flow.
El Afia, Fahd; Giraudet, Fabrice; Gilain, Laurent; Mom, Thierry; Avan, Paul
2017-01-01
The objective was to design in gerbils a model of reversible decrease in cochlear blood flow (CBF) and analyze its influence on cochlear function. In Mongolian gerbils injected with ferromagnetic microbeads, a magnet placed near the porus acusticus allowed CBF to be manipulated. The cochlear microphonic potential (CM) from the basal cochlea was monitored by a round-window electrode. In 13 of the 20 successfully injected gerbils, stable CBF reduction was obtained for 11.5 min on average. The CM was affected only when CBF fell to less than 60% of its baseline, yet remained >40% of its initial level in about 2/3 of such cases. After CBF restoration, CM recovery was fast and usually complete. Reduced CM came with a 35- to 45-dB threshold elevation of neural responses determined by compound action potentials. This method allowing reversible changes of CBF confirms the robustness of cochlear function to decreased CBF. It can be used to study whether a hypovascularized cochlea is abnormally sensitive to stress. © 2017 S. Karger AG, Basel.
Progress in Cochlear Physiology after Békésy
Guinan, John J.; Salt, Alec; Cheatham, Mary Ann
2012-01-01
In the fifty years since Békésy was awarded the Nobel Prize, cochlear physiology has blossomed. Many topics that are now current are things Békésy could not have imagined. In this review we start by describing progress in understanding the origin of cochlear gross potentials, particularly the cochlear microphonic, an area in which Békésy had extensive experience. We then review progress in areas of cochlear physiology that were mostly unknown to Békésy, including: (1) stereocilia mechano-electrical transduction, force production, and response amplification, (2) outer hair cell (OHC) somatic motility and its molecular basis in prestin, (3) cochlear amplification and related micromechanics, including the evidence that prestin is the main motor for cochlear amplification, (4) the influence of the tectorial membrane, (5) cochlear micromechanics and the mechanical drives to inner hair cell stereocilia, (6) otoacoustic emissions, and (7) olivocochlear efferents and their influence on cochlear physiology. We then return to a subject that Békésy knew well: cochlear fluids and standing currents, as well as our present understanding of energy dependence on the lateral wall of the cochlea. Finally, we touch on cochlear pathologies including noise damage and aging, with an emphasis on where the field might go in the future. PMID:22633944
Jones, Heath G; Kan, Alan; Litovsky, Ruth Y
2016-01-01
This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.
Investigating the role of radixin in modulation of stereocilia length and stiffness
NASA Astrophysics Data System (ADS)
Prasad, Sonal; Fridberger, Anders
2018-05-01
Mammalian hearing depends on deflection of stereocilia on the sensory outer hair cells of the inner ear. Previous data indicate that the stiffness of outer hair cell stereocilia are actively regulated. The molecular mechanism that regulate the deflection of stereocilia are presently less known. The aim of the study is to investigate the mechanistic pathway that underlie the stiffness modulation of outer hair cell stereocilia. Our hypothesis is that the membrane-cytoskeleton linker protein radixin, which is present at high concentration in stereocilia, could contribute to stiffness regulation. To test this hypothesis, we use the radixin blocker DX-52-1 which binds strongly and specifically to radixin. Time-resolved confocal imaging was used to visualize the sound-evoked motion of stereocilia in a semi-intact preparation of the guinea pig temporal bone. Cochlear microphonic potentials were also measured, using electrodes positioned in scala media. We found that the DX-52-1 inhibitor leads to an increase in stereocilia movements and decline in the amplitude of the cochlear microphonic potential. However, DX-52-1 caused a paradoxical increase in electromotility. These results suggest that radixin has a functionally important regulatory role in the mature inner ear.
Kirk, D L; Yates, G K
1998-01-01
Iontophoresis of 4-aminopyridine into scala media of the guinea pig cochlea caused elevation of the thresholds of the compound action potential of the auditory nerve, loss of amplitude of the extracellular cochlear microphonic response (CM), increase in the endocochlear potential (EP) and reduction in the amplitude of electrically evoked oto-acoustic emissions (EEOAEs). These changes were reversible over 10-20 min. The reciprocity of the changes in the CM and the EP was consistent with an interruption of both DC and AC currents through outer hair cells (OHCs), probably by blockade of mechano-electrical transduction (MET) channels in OHCs. Reductions in EEOAEs were consistent with the extrinsically applied generating current entering the OHC via the MET channels. Implications for the activation of OHC electromotility in vivo are discussed.
NASA Astrophysics Data System (ADS)
Yousefian Jazi, Nima
Spatial filtering and directional discrimination has been shown to be an effective pre-processing approach for noise reduction in microphone array systems. In dual-microphone hearing aids, fixed and adaptive beamforming techniques are the most common solutions for enhancing the desired speech and rejecting unwanted signals captured by the microphones. In fact, beamformers are widely utilized in systems where spatial properties of target source (usually in front of the listener) is assumed to be known. In this dissertation, some dual-microphone coherence-based speech enhancement techniques applicable to hearing aids are proposed. All proposed algorithms operate in the frequency domain and (like traditional beamforming techniques) are purely based on the spatial properties of the desired speech source and does not require any knowledge of noise statistics for calculating the noise reduction filter. This benefit gives our algorithms the ability to address adverse noise conditions, such as situations where interfering talker(s) speaks simultaneously with the target speaker. In such cases, the (adaptive) beamformers lose their effectiveness in suppressing interference, since the noise channel (reference) cannot be built and updated accordingly. This difference is the main advantage of the proposed techniques in the dissertation over traditional adaptive beamformers. Furthermore, since the suggested algorithms are independent of noise estimation, they offer significant improvement in scenarios that the power level of interfering sources are much more than that of target speech. The dissertation also shows the premise behind the proposed algorithms can be extended and employed to binaural hearing aids. The main purpose of the investigated techniques is to enhance the intelligibility level of speech, measured through subjective listening tests with normal hearing and cochlear implant listeners. However, the improvement in quality of the output speech achieved by the algorithms are also presented to show that the proposed methods can be potential candidates for future use in commercial hearing aids and cochlear implant devices.
Morawski, Krzysztof; Telischi, Fred F; Bohorquez, Jorge; Niemczyk, Kazimierz
2009-09-01
Local application of dexamethasone to the round window (RW) niche prevents cochlear damage caused by local reversible ischemia. Cochlear ischemia induced by internal auditory artery (IAA) compression/stretching is thought to cause postoperative sensory hearing loss after attempted hearing preservation removal of acoustic neuroma tumors. Dexamethasone administered to the RW niche traveling through the membrane to the cochlear fluids may prevent ischemic damage. Ten young albino rabbits were used for this study. Ischemic episodes were induced by compressing the IAA. Laser Doppler cochlear blood flow was measured using a probe positioned at the RW niche. Transtympanic electrocochleography was measured at 4, 8, and 12 kHz. In 5 test ears, dexamethasone was administered topically at the RW for approximately 50 minutes before the IAA compressions, whereas in 5 control ears, saline was applied in the same way. Each ear underwent one 10-minute IAA compression with a 60-minute postischemic period of transtympanic electrocochleography monitoring. In both control- and dexamethasone-treated ears, ischemic episodes measured by Laser Doppler cochlear blood flow were comparable. Fifty minutes after IAA decompression, in dexamethasone-pretreated ears, cochlear microphonic and compound action potential amplitudes at all test frequencies were 10 to 15% less reduced than those in control ears. Compound action potential latencies in dexamethasone-pretreated ears resulted in shorter latency delay than in control ears. The RW seems to be an efficacious route for the administration of dexamethasone into the inner ear. Dexamethasone showed a protective effect on cochlear function after local ischemia. Transtympanic electrocochleography was found to be a sufficient and effective tool in monitoring hearing.
ERIC Educational Resources Information Center
Davis, Timothy J.; Gifford, René H.
2018-01-01
Purpose: The primary purpose of this study was to derive spatial release from masking (SRM) performance-azimuth functions for bilateral cochlear implant (CI) users to provide a thorough description of SRM as a function of target/distracter spatial configuration. The secondary purpose of this study was to investigate the effect of the microphone…
Razza, Sergio; Zaccone, Monica; Meli, Aannalisa; Cristofari, Eliana
2017-12-01
Children affected by hearing loss can experience difficulties in challenging and noisy environments even when deafness is corrected by Cochlear implant (CI) devices. These patients have a selective attention deficit in multiple listening conditions. At present, the most effective ways to improve the performance of speech recognition in noise consists of providing CI processors with noise reduction algorithms and of providing patients with bilateral CIs. The aim of this study was to compare speech performances in noise, across increasing noise levels, in CI recipients using two kinds of wireless remote-microphone radio systems that use digital radio frequency transmission: the Roger Inspiro accessory and the Cochlear Wireless Mini Microphone accessory. Eleven Nucleus Cochlear CP910 CI young user subjects were studied. The signal/noise ratio, at a speech reception threshold (SRT) value of 50%, was measured in different conditions for each patient: with CI only, with the Roger or with the MiniMic accessory. The effect of the application of the SNR-noise reduction algorithm in each of these conditions was also assessed. The tests were performed with the subject positioned in front of the main speaker, at a distance of 2.5 m. Another two speakers were positioned at 3.50 m. The main speaker at 65 dB issued disyllabic words. Babble noise signal was delivered through the other speakers, with variable intensity. The use of both wireless remote microphones improved the SRT results. Both systems improved gain of speech performances. The gain was higher with the Mini Mic system (SRT = -4.76) than the Roger system (SRT = -3.01). The addition of the NR algorithm did not statistically further improve the results. There is significant improvement in speech recognition results with both wireless digital remote microphone accessories, in particular with the Mini Mic system when used with the CP910 processor. The use of a remote microphone accessory surpasses the benefit of application of NR algorithm. Copyright © 2017. Published by Elsevier B.V.
Spriet, Ann; Van Deun, Lieselot; Eftaxiadis, Kyriaky; Laneau, Johan; Moonen, Marc; van Dijk, Bas; van Wieringen, Astrid; Wouters, Jan
2007-02-01
This paper evaluates the benefit of the two-microphone adaptive beamformer BEAM in the Nucleus Freedom cochlear implant (CI) system for speech understanding in background noise by CI users. A double-blind evaluation of the two-microphone adaptive beamformer BEAM and a hardware directional microphone was carried out with five adult Nucleus CI users. The test procedure consisted of a pre- and post-test in the lab and a 2-wk trial period at home. In the pre- and post-test, the speech reception threshold (SRT) with sentences and the percentage correct phoneme scores for CVC words were measured in quiet and background noise at different signal-to-noise ratios. Performance was assessed for two different noise configurations (with a single noise source and with three noise sources) and two different noise materials (stationary speech-weighted noise and multitalker babble). During the 2-wk trial period at home, the CI users evaluated the noise reduction performance in different listening conditions by means of the SSQ questionnaire. In addition to the perceptual evaluation, the noise reduction performance of the beamformer was measured physically as a function of the direction of the noise source. Significant improvements of both the SRT in noise (average improvement of 5-16 dB) and the percentage correct phoneme scores (average improvement of 10-41%) were observed with BEAM compared to the standard hardware directional microphone. In addition, the SSQ questionnaire and subjective evaluation in controlled and real-life scenarios suggested a possible preference for the beamformer in noisy environments. The evaluation demonstrates that the adaptive noise reduction algorithm BEAM in the Nucleus Freedom CI-system may significantly increase the speech perception by cochlear implantees in noisy listening conditions. This is the first monolateral (adaptive) noise reduction strategy actually implemented in a mainstream commercial CI.
The influence of transducer operating point on distortion generation in the cochlea
NASA Astrophysics Data System (ADS)
Sirjani, Davud B.; Salt, Alec N.; Gill, Ruth M.; Hale, Shane A.
2004-03-01
Distortion generated by the cochlea can provide a valuable indicator of its functional state. In the present study, the dependence of distortion on the operating point of the cochlear transducer and its relevance to endolymph volume disturbances has been investigated. Calculations have suggested that as the operating point moves away from zero, second harmonic distortion would increase. Cochlear microphonic waveforms were analyzed to derive the cochlear transducer operating point and to quantify harmonic distortions. Changes in operating point and distortion were measured during endolymph manipulations that included 200-Hz tone exposures at 115-dB SPL, injections of artificial endolymph into scala media at 80, 200, or 400 nl/min, and treatment with furosemide given intravenously or locally into the cochlea. Results were compared with other functional changes that included action potential thresholds at 2.8 or 8 kHz, summating potential, endocochlear potential, and the 2 f1-f2 and f2-f1 acoustic emissions. The results demonstrated that volume disturbances caused changes in the operating point that resulted in predictable changes in distortion. Understanding the factors influencing operating point is important in the interpretation of distortion measurements and may lead to tests that can detect abnormal endolymph volume states.
Lohuis, P J; Börjesson, P K; Klis, S F; Smoorenburg, G F
2000-05-01
Circulating adrenal hormones affect strial function. Removal of endogenous levels of adrenal steroids by bilateral adrenalectomy (ADX) in rats causes a decrease of Na(+)/K(+)-ATPase activity in the cochlear lateral wall [Rarey et al., 1989. Arch. Otolaryngol. Head Neck Surg. 115, 817-821] and a decrease of the volume of the marginal cells in the stria vascularis [Lohuis et al., 1990. Acta Otolaryngol. (Stockh.) 110, 348-356]. To study further the effect of absence of circulating adrenocorticosteroids on cochlear function, 18 male Long Evans rats underwent either an ADX or a SHAM operation. Electrocochleography was performed 1 week after surgery for tone bursts in a frequency range of 1-16 kHz. Thereafter, the cochleas were harvested and examined histologically. No significant changes in the amplitude growth curves of the summating potential (SP), the compound action potential (CAP) and the cochlear microphonics (CM) were detected after ADX. However, visually, there appeared to be a decrease of endolymphatic volume (tentatively called imdrops). Reissner's membrane (RM) extended less into scala vestibuli in ADX animals than in SHAM-operated animals. The ratio between the length of RM and the straight distance between the medial and lateral attachment points of RM were used as an objective measure to quantify this effect in each sub-apical half turn of the cochlea. The decrease in length of RM was statistically significant. Thus, circulating adrenal hormones appear to be necessary for normal cochlear fluid homeostasis. Absence of one or more of these hormones leads to shrinkage of the scala media (imdrops). However, the absence of adrenal hormones does not affect the gross cochlear potentials. Apparently, the cochlea is capable of compensating for the absence of circulating adrenal hormones to sustain the conditions necessary for proper cochlear transduction.
Auditory Cortex Basal Activity Modulates Cochlear Responses in Chinchillas
León, Alex; Elgueda, Diego; Silva, María A.; Hamamé, Carlos M.; Delano, Paul H.
2012-01-01
Background The auditory efferent system has unique neuroanatomical pathways that connect the cerebral cortex with sensory receptor cells. Pyramidal neurons located in layers V and VI of the primary auditory cortex constitute descending projections to the thalamus, inferior colliculus, and even directly to the superior olivary complex and to the cochlear nucleus. Efferent pathways are connected to the cochlear receptor by the olivocochlear system, which innervates outer hair cells and auditory nerve fibers. The functional role of the cortico-olivocochlear efferent system remains debated. We hypothesized that auditory cortex basal activity modulates cochlear and auditory-nerve afferent responses through the efferent system. Methodology/Principal Findings Cochlear microphonics (CM), auditory-nerve compound action potentials (CAP) and auditory cortex evoked potentials (ACEP) were recorded in twenty anesthetized chinchillas, before, during and after auditory cortex deactivation by two methods: lidocaine microinjections or cortical cooling with cryoloops. Auditory cortex deactivation induced a transient reduction in ACEP amplitudes in fifteen animals (deactivation experiments) and a permanent reduction in five chinchillas (lesion experiments). We found significant changes in the amplitude of CM in both types of experiments, being the most common effect a CM decrease found in fifteen animals. Concomitantly to CM amplitude changes, we found CAP increases in seven chinchillas and CAP reductions in thirteen animals. Although ACEP amplitudes were completely recovered after ninety minutes in deactivation experiments, only partial recovery was observed in the magnitudes of cochlear responses. Conclusions/Significance These results show that blocking ongoing auditory cortex activity modulates CM and CAP responses, demonstrating that cortico-olivocochlear circuits regulate auditory nerve and cochlear responses through a basal efferent tone. The diversity of the obtained effects suggests that there are at least two functional pathways from the auditory cortex to the cochlea. PMID:22558383
Santarelli, Rosamaria; Starr, Arnold; Michalewski, Henry J; Arslan, Edoardo
2008-05-01
Transtympanic electrocochleography (ECochG) was recorded bilaterally in children and adults with auditory neuropathy (AN) to evaluate receptor and neural generators. Test stimuli were clicks from 60 to 120dB p.e. SPL. Measures obtained from eight AN subjects were compared to 16 normally hearing children. Receptor cochlear microphonics (CMs) in AN were of normal or enhanced amplitude. Neural compound action potentials (CAPs) and receptor summating potentials (SPs) were identified in five AN ears. ECochG potentials in those ears without CAPs were of negative polarity and of normal or prolonged duration. We used adaptation to rapid stimulus rates to distinguish whether the generators of the negative potentials were of neural or receptor origin. Adaptation in controls resulted in amplitude reduction of CAP twice that of SP without affecting the duration of ECochG potentials. In seven AN ears without CAP and with prolonged negative potential, adaptation was accompanied by reduction of both amplitude and duration of the negative potential to control values consistent with neural generation. In four ears without CAP and with normal duration potentials, adaptation was without effect consistent with receptor generation. In five AN ears with CAP, there was reduction in amplitude of CAP and SP as controls but with a significant decrease in response duration. Three patterns of cochlear potentials were identified in AN: (1) presence of receptor SP without CAP consistent with pre-synaptic disorder of inner hair cells; (2) presence of both SP and CAP consistent with post-synaptic disorder of proximal auditory nerve; (3) presence of prolonged neural potentials without a CAP consistent with post-synaptic disorder of nerve terminals. Cochlear potential measures may identify pre- and post-synaptic disorders of inner hair cells and auditory nerves in AN.
The auditory nerve overlapped waveform (ANOW): A new objective measure of low-frequency hearing
NASA Astrophysics Data System (ADS)
Lichtenhan, Jeffery T.; Salt, Alec N.; Guinan, John J.
2015-12-01
One of the most pressing problems today in the mechanics of hearing is to understand the mechanical motions in the apical half of the cochlea. Almost all available measurements from the cochlear apex of basilar membrane or other organ-of-Corti transverse motion have been made from ears where the health, or sensitivity, in the apical half of the cochlea was not known. A key step in understanding the mechanics of the cochlear base was to trust mechanical measurements only when objective measures from auditory-nerve compound action potentials (CAPs) showed good preparation sensitivity. However, such traditional objective measures are not adequate monitors of cochlear health in the very low-frequency regions of the apex that are accessible for mechanical measurements. To address this problem, we developed the Auditory Nerve Overlapped Waveform (ANOW) that originates from auditory nerve output in the apex. When responses from the round window to alternating low-frequency tones are averaged, the cochlear microphonic is canceled and phase-locked neural firing interleaves in time (i.e., overlaps). The result is a waveform that oscillates at twice the probe frequency. We have demonstrated that this Auditory Nerve Overlapped Waveform - called ANOW - originates from auditory nerve fibers in the cochlear apex [8], relates well to single-auditory-nerve-fiber thresholds, and can provide an objective estimate of low-frequency sensitivity [7]. Our new experiments demonstrate that ANOW is a highly sensitive indicator of apical cochlear function. During four different manipulations to the scala media along the cochlear spiral, ANOW amplitude changed when either no, or only small, changes occurred in CAP thresholds. Overall, our results demonstrate that ANOW can be used to monitor cochlear sensitivity of low-frequency regions during experiments that make apical basilar membrane motion measurements.
Baumgärtel, Regina M; Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias
2015-12-30
Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. © The Author(s) 2015.
Tan, C; Cao, Y; Hu, P
1998-09-01
Inquire into the mechanism of inner ear pathological physiology in autoimmune sensorineural hearing loss (ASHL). With the auditory electric-physiological techniques and enzyme-histochemical method, the change of inner ear hearing function and enzyme activity were observed. These animals, which threshold of auditory nerve compound active potential (CAP) and cochlear microphonic potential(CM) heightening evidently, showed that the amplitude of endolymphatic potential(EP) (include-EP) bring down in various degrees, which was related to the change of the active of Na(+)-K(+)-ATPase and SDH in vascularis stria and endolymphatic sac. The abnormality of enzymes metabolism in inner ear tissues, which following autoimmune inflammation damage, is the pathological foundation of hearing dysfunction.
The effect of BAPTA and 4AP in scala media on transduction and cochlear gain.
Sellick, P M; Robertson, D; Patuzzi, R
2006-01-01
We have injected by iontophoresis 4-amino-pyridine, a K+ channel blocker and BAPTA, (a Ca++ chelator), into scala media of the first three turns of the guinea pig cochlea. We measured the reduction in outer hair cell (OHC) receptor current, as indicated by cochlear microphonic measured in scala media evoked by a 207 Hz tone, and compared this with the elevation of the cochlear action potential (CAP) threshold. We found that in the basal turn, for frequencies between 12 and 21 kHz, CAP threshold was elevated by about 30 dB, while in the second turn, at the 3 kHz place, the maximum elevation was 15 dB. In the third turn, iontophoresis of 4AP and BAPTA reduced CM by similar amounts to that in the basal and second turn, but caused negligible elevation of CAP threshold. We conclude that the gain of the cochlear amplifier is maximal for basal turn frequencies, is halved at 3 kHz, and is reduced to close to one for frequencies below 1 kHz (no active gain). The effect of 4AP and BAPTA on neural threshold and the receptor current represented by CM may be explained by their action on OHC transduction without the involvement of IHCs.
Long term effects of BAPTA in scala media on cochlear function.
Sellick, Peter M
2007-09-01
BAPTA was iontophoresed or allowed to diffuse into the scala media of the first turn of the guinea pig cochlea via pipettes inserted through the round window and basilar membrane. Cochlear action potential (CAP) thresholds for basal turn frequencies were elevated, scala media cochlear microphonic in response to a 207Hz tone were drastically reduced and the distortion products 2f1-f2 and f2-f2 in response to primaries set at 18 and 21.6kHz were eliminated or severely reduced. The animals were recovered and the above measurements repeated between 24 and 240h after the application of BAPTA. In all animals thresholds for basal turn frequencies remained elevated, and the distortion components were severely reduced. The endolymphatic potential (EP), measured through the basilar membrane on recovery, was not significantly different from the values measured before BAPTA was applied. If the effect of BAPTA, in lowering endolymphatic Ca(2+) concentration, is restricted to the destruction of tip links, as has been shown in many other preparations, then these results suggest that this effect has permanent consequences, either because the tip links failed to regenerate or because their destruction precipitated the degeneration of OHCs. These results may have a bearing on the mechanisms behind permanent threshold shift.
Displacements of the organ of Corti by gel injections into the cochlear apex
Salt, Alec N.; Brown, Daniel J.; Hartsock, Jared J.; Plontke, Stefan K.
2009-01-01
In order to transduce sounds efficiently, the stereocilia of hair cells in the organ of Corti must be positioned optimally. Mechanical displacements, such as pressure differentials across the organ caused by endolymphatic hydrops, may impair sensitivity. Studying this phenomenon has been limited by the technical difficulty of inducing sustained displacements of stereocilia in vivo. We have found that small injections (0.5 to 2 μL) of Healon gel into the cochlear apex of guinea pigs produced sustained changes of endocochlear potential (EP), summating potential (SP) and transducer operating point (OP) in a manner consistent with a mechanically-induced position change of the organ of Corti in the basal turn. Induced changes immediately recovered when injection ceased. In addition, effects of low-frequency bias tones on EP, SP and OP were enhanced during the injection of gel and remained hypersensitive after injection ceased. This is thought to result from the viscous gel mechanically limiting pressure shunting through the helicotrema. Cochlear microphonics measured as frequency was varied showed enhancement below 100 Hz but most notably in the sub-auditory range. Sensitivity to low-frequency biasing was also enhanced in animals with surgically-induced endolymphatic hydrops, suggesting that obstruction of the perilymphatic space by hydrops could contribute to the pathophysiology of this condition. PMID:19217935
The Effects of Electromagnetic Fields on The Nervous System,
Superior Cervical Ganglia: Design of Waveguide Apparatus, and Calculation of Specific Absorption Rate; Effects of Electromagnetic Fields on Muscle ... Contraction ; Effects of Electromagnetic Fields on Auditory System: Effect of Noise Masking on Threshold of Evoked Auditory Responses, Microwave-induced Cochlear Microphonics in Guinea Pigs.
Inner ear injury caused by air intrusion to the scala vestibuli of the cochlea.
Kobayashi, T; Sakurada, T; Ohyama, K; Takasaka, M
1993-11-01
In a previous communication, we demonstrated that the introduction of air into the scala tympani of the cochlea causes a decrease of cochlear potentials; however, the change in endocochlear dc potential (EP) was mild and the decreased cochlear microphonics (CM) and compound action potentials (CAP) were, at least partially, reversible. In contrast, we have now found that air perfusion (3-60 microliters/min) in the scala vestibuli decreased cochlear potentials more drastically than that in the scala tympani. The change in the EP after air perfusion in the scala vestibuli was characterized by a decrease of the negative EP in response to anoxia. The CM drastically decreased upon the initiation of air perfusion and no recovery was observed after refilling of the perilymph. Histological examination showed collapse of Reissner's membrane in 12 out of 17 cochleas examined. The extent and frequency of the collapse increased with an increase in the amount of air perfused in the scala vestibuli. As the minimal amount of air needed to cause inner ear damage by air perfusion in the scala vestibuli is as small as 3 microliters, it is possible that the prognosis is worse in cases with fistula of the oval window compared to that of the round window area, if the pneumolabyrinth is involved in the pathophysiology of perilymphatic fistula. It is also indicated that air inflation of the middle ear is dangerous in cases with fistula in the oval window.
Wolfe, Jace; Morais Duke, Mila; Schafer, Erin; Cire, George; Menapace, Christine; O'Neill, Lori
2016-01-01
The objective of this study was to evaluate the potential improvement in word recognition in quiet and in noise obtained with use of a Bluetooth-compatible wireless hearing assistance technology (HAT) relative to the acoustic mobile telephone condition (e.g. the mobile telephone receiver held to the microphone of the sound processor). A two-way repeated measures design was used to evaluate differences in telephone word recognition obtained in quiet and in competing noise in the acoustic mobile telephone condition compared to performance obtained with use of the CI sound processor and a telephone HAT. Sixteen adult users of Nucleus cochlear implants and the Nucleus 6 sound processor were included in this study. Word recognition over the mobile telephone in quiet and in noise was significantly better with use of the wireless HAT compared to performance in the acoustic mobile telephone condition. Word recognition over the mobile telephone was better in quiet when compared to performance in noise. The results of this study indicate that use of a wireless HAT improves word recognition over the mobile telephone in quiet and in noise relative to performance in the acoustic mobile telephone condition for a group of adult cochlear implant recipients.
NASA Astrophysics Data System (ADS)
Naghibolhosseini, Maryam
Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To better assess cochlear health using OAEs, it is critical to quantify the impact of the outer and middle ear on sound transmission. The reported research introduces a noninvasive approach to estimate outer-middle ear transmission using distortion product otoacoustic emissions (DPOAEs). In addition, the role of the outer and middle ear on sound transmission was investigated by developing a physical/mathematical model, which employed fractional-order lumped elements to include the viscoelastic characteristics of biological tissues. Impedance estimations from wideband refectance measurements were used for parameter fitting of the model. The model was validated comparing its estimates of the outer-middle ear sound transmission with those given by DPOAEs. The outer-middle ear transmission by the model was defined as the sum of forward and reverse outer-middle ear transmissions. To estimate the reverse transmission by the model, the probe-microphone impedance was calculated through estimating the Thevenin-equivalent circuit of the probe-microphone. The Thevenin-equivalent circuit was calculated using measurements in a number of test cavities. Such modeling enhances our understanding of the roles of different parts of the outer and middle ear and how they work together to determine their function. In addition, the model would be potentially helpful in diagnosing pathologies of cochlear or middle ear origin.
Goldsworthy, Raymond L.; Delhorne, Lorraine A.; Desloge, Joseph G.; Braida, Louis D.
2014-01-01
This article introduces and provides an assessment of a spatial-filtering algorithm based on two closely-spaced (∼1 cm) microphones in a behind-the-ear shell. The evaluated spatial-filtering algorithm used fast (∼10 ms) temporal-spectral analysis to determine the location of incoming sounds and to enhance sounds arriving from straight ahead of the listener. Speech reception thresholds (SRTs) were measured for eight cochlear implant (CI) users using consonant and vowel materials under three processing conditions: An omni-directional response, a dipole-directional response, and the spatial-filtering algorithm. The background noise condition used three simultaneous time-reversed speech signals as interferers located at 90°, 180°, and 270°. Results indicated that the spatial-filtering algorithm can provide speech reception benefits of 5.8 to 10.7 dB SRT compared to an omni-directional response in a reverberant room with multiple noise sources. Given the observed SRT benefits, coupled with an efficient design, the proposed algorithm is promising as a CI noise-reduction solution. PMID:25096120
Dorman, Michael F; Natale, Sarah; Loiselle, Louise
2018-03-01
Sentence understanding scores for patients with cochlear implants (CIs) when tested in quiet are relatively high. However, sentence understanding scores for patients with CIs plummet with the addition of noise. To assess, for patients with CIs (MED-EL), (1) the value to speech understanding of two new, noise-reducing microphone settings and (2) the effect of the microphone settings on sound source localization. Single-subject, repeated measures design. For tests of speech understanding, repeated measures on (1) number of CIs (one, two), (2) microphone type (omni, natural, adaptive beamformer), and (3) type of noise (restaurant, cocktail party). For sound source localization, repeated measures on type of signal (low-pass [LP], high-pass [HP], broadband noise). Ten listeners, ranging in age from 48 to 83 yr (mean = 57 yr), participated in this prospective study. Speech understanding was assessed in two noise environments using monaural and bilateral CIs fit with three microphone types. Sound source localization was assessed using three microphone types. In Experiment 1, sentence understanding scores (in terms of percent words correct) were obtained in quiet and in noise. For each patient, noise was first added to the signal to drive performance off of the ceiling in the bilateral CI-omni microphone condition. The other conditions were then administered at that signal-to-noise ratio in quasi-random order. In Experiment 2, sound source localization accuracy was assessed for three signal types using a 13-loudspeaker array over a 180° arc. The dependent measure was root-mean-score error. Both the natural and adaptive microphone settings significantly improved speech understanding in the two noise environments. The magnitude of the improvement varied between 16 and 19 percentage points for tests conducted in the restaurant environment and between 19 and 36 percentage points for tests conducted in the cocktail party environment. In the restaurant and cocktail party environments, both the natural and adaptive settings, when implemented on a single CI, allowed scores that were as good as, or better, than scores in the bilateral omni test condition. Sound source localization accuracy was unaltered by either the natural or adaptive settings for LP, HP, or wideband noise stimuli. The data support the use of the natural microphone setting as a default setting. The natural setting (1) provides better speech understanding in noise than the omni setting, (2) does not impair sound source localization, and (3) retains low-frequency sensitivity to signals from the rear. Moreover, bilateral CIs equipped with adaptive beamforming technology can engender speech understanding scores in noise that fall only a little short of scores for a single CI in quiet. American Academy of Audiology
De Ceulaer, Geert; Bestel, Julie; Mülder, Hans E; Goldbeck, Felix; de Varebeke, Sebastien Pierre Janssens; Govaerts, Paul J
2016-05-01
Roger is a digital adaptive multi-channel remote microphone technology that wirelessly transmits a speaker's voice directly to a hearing instrument or cochlear implant sound processor. Frequency hopping between channels, in combination with repeated broadcast, avoids interference issues that have limited earlier generation FM systems. This study evaluated the benefit of the Roger Pen transmitter microphone in a multiple talker network (MTN) for cochlear implant users in a simulated noisy conversation setting. Twelve post-lingually deafened adult Advanced Bionics CII/HiRes 90K recipients were recruited. Subjects used a Naida CI Q70 processor with integrated Roger 17 receiver. The test environment simulated four people having a meal in a noisy restaurant, one the CI user (listener), and three companions (talkers) talking non-simultaneously in a diffuse field of multi-talker babble. Speech reception thresholds (SRTs) were determined without the Roger Pen, with one Roger Pen, and with three Roger Pens in an MTN. Using three Roger Pens in an MTN improved the SRT by 14.8 dB over using no Roger Pen, and by 13.1 dB over using a single Roger Pen (p < 0.0001). The Roger Pen in an MTN provided statistically and clinically significant improvement in speech perception in noise for Advanced Bionics cochlear implant recipients. The integrated Roger 17 receiver made it easy for users of the Naida CI Q70 processor to take advantage of the Roger system. The listening advantage and ease of use should encourage more clinicians to recommend and fit Roger in adult cochlear implant patients.
Echeverría, E L; Robles, L W
1983-02-01
Cochlear microphonic (CM) responses to acoustic transient stimuli were studied at the three more basal turns of the cochlea in the guinea pig. The responses to rarefaction and condensation pressure pulses of less than 100-mus duration were recorded using the differential electrode technique. In some animals the CM response to pure tones was recorded at the same position at which the transient response was obtained. The transient responses recorded at the three turns of the cochlea displayed a damped oscillation at a frequency consistent with the values of cutoff frequency already known for the electrode positions. Some of the responses were significantly less damped than click responses previously reported. There was a good correlation between the cutoff frequency in the frequency response curve and the frequency of oscillation in the transient response for recordings obtained at the same position in the cochlea. A nonlinear effect was observed for changes in stimulus intensity. There was a less than proportional decrease in amplitude of the initial part of the damped oscillation for a decrease of the stimulus intensity, while the late part of the response behaved almost linearly. This nonlinearity observed in the CM transient response could not be explained by a nonlinear characteristic of the sort reported in the basilar membrane of the squirrel monkey by Robles et al. [J. Acoust. Soc. Am. 59, 926-939 (1976)]; rather it seems to be a saturation nonlinearity similar to the one known for sinusoidal stimulation.
In situ Probe Microphone Measurement for Testing the Direct Acoustical Cochlear Stimulator.
Stieger, Christof; Alnufaily, Yasser H; Candreia, Claudia; Caversaccio, Marco D; Arnold, Andreas M
2017-01-01
Hypothesis: Acoustical measurements can be used for functional control of a direct acoustic cochlear stimulator (DACS). Background: The DACS is a recently released active hearing implant that works on the principle of a conventional piston prosthesis driven by the rod of an electromagnetic actuator. An inherent part of the DACS actuator is a thin titanium diaphragm that allows for movement of the stimulation rod while hermetically sealing the housing. In addition to mechanical stimulation, the actuator emits sound into the mastoid cavity because of the motion of the diaphragm. Methods: We investigated the use of the sound emission of a DACS for intra-operative testing. We measured sound emission in the external auditory canal (P EAC ) and velocity of the actuators stimulation rod (V act ) in five implanted ears of whole-head specimens. We tested the influence various positions of the loudspeaker and a probe microphone on P EAC and simulated implant malfunction in one example. Results: Sound emission of the DACS with a signal-to-noise ratio >10 dB was observed between 0.5 and 5 kHz. Simulated implant misplacement or malfunction could be detected by the absence or shift in the characteristic resonance frequency of the actuator. P EAC changed by <6 dB for variations of the microphone and loudspeaker position. Conclusion: Our data support the feasibility of acoustical measurements for in situ testing of the DACS implant in the mastoid cavity as well as for post-operative monitoring of actuator function.
Koka, Kanthaiah; Saoji, Aniket A; Attias, Joseph; Litvak, Leonid M
2017-01-01
Although, cochlear implants (CI) traditionally have been used to treat individuals with bilateral profound sensorineural hearing loss, a recent trend is to implant individuals with residual low-frequency hearing. Notably, many of these individuals demonstrate an air-bone gap (ABG) in low-frequency, pure-tone thresholds following implantation. An ABG is the difference between audiometric thresholds measured using air conduction (AC) and bone conduction (BC) stimulation. Although, behavioral AC thresholds are straightforward to assess, BC thresholds can be difficult to measure in individuals with severe-to-profound hearing loss because of vibrotactile responses to high-level, low-frequency stimulation and the potential contribution of hearing in the contralateral ear. Because of these technical barriers to measuring behavioral BC thresholds in implanted patients with residual hearing, it would be helpful to have an objective method for determining ABG. This study evaluated an innovative technique for measuring electrocochleographic (ECochG) responses using the cochlear microphonic (CM) response to assess AC and BC thresholds in implanted patients with residual hearing. Results showed high correlations between CM thresholds and behavioral audiograms for AC and BC conditions, thereby demonstrating the feasibility of using ECochG as an objective tool for quantifying ABG in CI recipients.
The effect of injection of high K+ solution into scala media.
Fukazawa, T; Ohmura, M; Yagi, N
1987-01-01
Thirty guinea pig ears were studied to investigate the effect of endolymphatic hydrops on the cochlea. High K+ solution was injected into the scala media, and cochlear microphonics (CM) and endocochlear potential (EP) were observed before, during and after the injection. The CM amplitude decreased rapidly after injection, ending in a depressed plateau value. By contrast, EP remained almost unchanged. By changing the composition of the solution it was suggested that the effect of the injection was mechanical one, rather than biochemical. In three ears, spontaneous recovery of CM was observed during a relatively long interval after the injection. The meaning of these findings for the hearing loss in Meniere's disease is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamura, K.; Maehara, N.; Terayama, K.
Segmental demyelination and axonal degeneration of motor nerves induced by lead exposure is well known in man, and animals. The effect of lead acetate exposure to man may involve the cranial nerves, since vertigo and sensory neuronal deafness have been reported among lead workers. However, there are few reports concerning the dose-effects of lead acetate both to the peripheral nerve and the cranial VII nerve with measurement of blood lead concentration. The authors investigated the effects of lead acetate to the cochlea and the VIII nerve using CM (cochlear microphonics) and AP (action potential) of the guinea pigs. The effectsmore » of lead acetate to the sciatic nerve were measured by MCV of the sciatic nerve with measurement of blood lead concentration.« less
Impact of a Moving Noise Masker on Speech Perception in Cochlear Implant Users
Weissgerber, Tobias; Rader, Tobias; Baumann, Uwe
2015-01-01
Objectives Previous studies investigating speech perception in noise have typically been conducted with static masker positions. The aim of this study was to investigate the effect of spatial separation of source and masker (spatial release from masking, SRM) in a moving masker setup and to evaluate the impact of adaptive beamforming in comparison with fixed directional microphones in cochlear implant (CI) users. Design Speech reception thresholds (SRT) were measured in S0N0 and in a moving masker setup (S0Nmove) in 12 normal hearing participants and 14 CI users (7 subjects bilateral, 7 bimodal with a hearing aid in the contralateral ear). Speech processor settings were a moderately directional microphone, a fixed beamformer, or an adaptive beamformer. The moving noise source was generated by means of wave field synthesis and was smoothly moved in a shape of a half-circle from one ear to the contralateral ear. Noise was presented in either of two conditions: continuous or modulated. Results SRTs in the S0Nmove setup were significantly improved compared to the S0N0 setup for both the normal hearing control group and the bilateral group in continuous noise, and for the control group in modulated noise. There was no effect of subject group. A significant effect of directional sensitivity was found in the S0Nmove setup. In the bilateral group, the adaptive beamformer achieved lower SRTs than the fixed beamformer setting. Adaptive beamforming improved SRT in both CI user groups substantially by about 3 dB (bimodal group) and 8 dB (bilateral group) depending on masker type. Conclusions CI users showed SRM that was comparable to normal hearing subjects. In listening situations of everyday life with spatial separation of source and masker, directional microphones significantly improved speech perception with individual improvements of up to 15 dB SNR. Users of bilateral speech processors with both directional microphones obtained the highest benefit. PMID:25970594
Salt, A N; DeMott, J E
1999-08-01
The inner ear is continually exposed to pressure fluctuations in the infrasonic frequency range (< 20 Hz) from external and internal body sources. The cochlea is generally regarded to be insensitive to such stimulation. The effects of stimulation at infrasonic frequencies (0.1 to 10 Hz) on endocochlear potential (EP) and endolymph movements in the guinea pig cochlea were studied. Stimuli were applied directly to the perilymph of scala tympani or scala vestibuli of the cochlea via a fluid-filled pipette. Stimuli, especially those near 1 Hz, elicited large EP changes which under some conditions exceeded 20 mV in amplitude and were equivalent to a cochlear microphonic (CM) response. Accompanying the electrical responses was a cyclical, longitudinal displacement of the endolymph. The amplitude and phase of the CM varied according to which perilymphatic scala the stimuli were applied to and whether a perforation was made in the opposing perilymphatic scala. Spontaneously occurring middle ear muscle contractions were also found to induce EP deflections and longitudinal endolymph movements comparable to those generated by perilymphatic injections. These findings suggest that cochlear fluid movements induced by pressure fluctuations at infrasonic frequencies could play a role in fluid homeostasis in the normal state and in fluid disturbances in pathological states.
NASA Astrophysics Data System (ADS)
Bohórquez, Jorge; Özdamar, Özcan; Morawski, Krzysztof; Telischi, Fred F.; Delgado, Rafael E.; Yavuz, Erdem
2005-06-01
A system capable of comprehensive and detailed monitoring of the cochlea and the auditory nerve during intraoperative surgery was developed. The cochlear blood flow (CBF) and the electrocochleogram (ECochGm) were recorded at the round window (RW) niche using a specially designed otic probe. The ECochGm was further processed to obtain cochlear microphonics (CM) and compound action potentials (CAP).The amplitude and phase of the CM were used to quantify the activity of outer hair cells (OHC); CAP amplitude and latency were used to describe the auditory nerve and the synaptic activity of the inner hair cells (IHC). In addition, concurrent monitoring with a second electrophysiological channel was achieved by recording compound nerve action potential (CNAP) obtained directly from the auditory nerve. Stimulation paradigms, instrumentation and signal processing methods were developed to extract and differentiate the activity of the OHC and the IHC in response to three different frequencies. Narrow band acoustical stimuli elicited CM signals indicating mainly nonlinear operation of the mechano-electrical transduction of the OHCs. Special envelope detectors were developed and applied to the ECochGm to extract the CM fundamental component and its harmonics in real time. The system was extensively validated in experimental animal surgeries by performing nerve compressions and manipulations.
Acoustic Events and “Optophonic” Cochlear Responses Induced by Pulsed Near-Infrared LASER
Maier, Hannes; Richter, Claus-Peter; Kral, Andrej
2012-01-01
Optical stimulation of neural tissue within the cochlea was described as a possible alternative to electrical stimulation. Most optical stimulation was performed with pulsed lasers operating with near-infrared (NIR) light and in thermal confinement. Under these conditions, the coexistence of laser-induced optoacoustic stimulation of the cochlea (“optophony”) has not been analyzed yet. This study demonstrates that pulsed 1850-nm laser light used for neural stimulation also results in sound pressure levels up to 62 dB peak-to-peak equivalent sound pressure level (SPL) in air. The sound field was confined to a small volume along the laser beam. In dry nitrogen, laser-induced acoustic events disappeared. Hydrophone measurements demonstrated pressure waves for laser fibers immersed in water. In hearing rats, laser-evoked signals were recorded from the cochlea without targeting neural tissue. The signals showed a two-domain response differing in amplitude and latency functions, as well as sensitivity to white-noise masking. The first component had characteristics of a cochlear microphonic potential, and the second component was characteristic for a compound action potential. The present data demonstrate that laser-evoked acoustic events can stimulate a hearing cochlea. Whenever optical stimulation is used, care must be taken to distinguish between such “optophony” and the true optoneural response. PMID:21278011
2014-01-01
This study evaluates a spatial-filtering algorithm as a method to improve speech reception for cochlear-implant (CI) users in reverberant environments with multiple noise sources. The algorithm was designed to filter sounds using phase differences between two microphones situated 1 cm apart in a behind-the-ear hearing-aid capsule. Speech reception thresholds (SRTs) were measured using a Coordinate Response Measure for six CI users in 27 listening conditions including each combination of reverberation level (T60 = 0, 270, and 540 ms), number of noise sources (1, 4, and 11), and signal-processing algorithm (omnidirectional response, dipole-directional response, and spatial-filtering algorithm). Noise sources were time-reversed speech segments randomly drawn from the Institute of Electrical and Electronics Engineers sentence recordings. Target speech and noise sources were processed using a room simulation method allowing precise control over reverberation times and sound-source locations. The spatial-filtering algorithm was found to provide improvements in SRTs on the order of 6.5 to 11.0 dB across listening conditions compared with the omnidirectional response. This result indicates that such phase-based spatial filtering can improve speech reception for CI users even in highly reverberant conditions with multiple noise sources. PMID:25330772
Aedo, Cristian; Tapia, Eduardo; Pavez, Elizabeth; Elgueda, Diego; Delano, Paul H; Robles, Luis
2015-01-01
There are two types of sensory cells in the mammalian cochlea, inner hair cells, which make synaptic contact with auditory-nerve afferent fibers, and outer hair cells that are innervated by crossed and uncrossed medial olivocochlear (MOC) efferent fibers. Contralateral acoustic stimulation activates the uncrossed efferent MOC fibers reducing cochlear neural responses, thus modifying the input to the central auditory system. The chinchilla, among all studied mammals, displays the lowest percentage of uncrossed MOC fibers raising questions about the strength and frequency distribution of the contralateral-sound effect in this species. On the other hand, MOC effects on cochlear sensitivity have been mainly studied in anesthetized animals and since the MOC-neuron activity depends on the level of anesthesia, it is important to assess the influence of anesthesia in the strength of efferent effects. Seven adult chinchillas (Chinchilla laniger) were chronically implanted with round-window electrodes in both cochleae. We compared the effect of contralateral sound in awake and anesthetized condition. Compound action potentials (CAP) and cochlear microphonics (CM) were measured in the ipsilateral cochlea in response to tones in absence and presence of contralateral sound. Control measurements performed after middle-ear muscles section in one animal discarded any possible middle-ear reflex activation. Contralateral sound produced CAP amplitude reductions in all chinchillas, with suppression effects greater by about 1-3 dB in awake than in anesthetized animals. In contrast, CM amplitude increases of up to 1.9 dB were found in only three awake chinchillas. In both conditions the strongest efferent effects were produced by contralateral tones at frequencies equal or close to those of ipsilateral tones. Contralateral CAP suppressions for 1-6 kHz ipsilateral tones corresponded to a span of uncrossed MOC fiber innervation reaching at least the central third of the chinchilla cochlea.
Effects of Stimulus Intensity on Low-Frequency Toneburst Cochlear Microphonic Waveforms.
Zhang, Ming
2013-01-02
This study investigates changes in amplitude and delays in low-frequency toneburst cochlear microphonic (CM) waveforms recorded at the ear canal in response to different stimulus intensities. Ten volunteers aged 20-30 were recruited. Low-frequency CM waveforms at 500 Hz in response to a 14-ms toneburst were recorded from an ear canal electrode using electrocochleography techniques. The data was statistically analyzed in order to confirm whether the differences were significant in the effects of stimulus intensity on the amplitudes and delays of the low-frequency CM waveforms. Electromagnetic interference artifacts can jeopardize CM measurements but such artifacts can be avoided. The CM waveforms can be recorded at the ear canal in response to a toneburst which is longer than that used in ABR measurements. The CM waveforms thus recorded are robust, and the amplitude of CM waveforms is intensity-dependent. In contrast, the delay of CM waveforms is intensity-independent, which is different from neural responses as their delay or latency is intensity-dependent. These findings may be useful for development of the application of CM measurement as a supplementary approach to otoacoustic emission (OAE) measurement in the clinic which is severely affected by background acoustic noise. The development of the application in the assessment of low-frequency cochlear function may become possible if a further series of studies can verify the feasibility, but it is not meant to be a substitute for audiometry or OAE measurements. The measurement of detection threshold of CM waveform responses using growth function approach may become possible in the clinic. The intensity-independent nature of CMs with regards to delay measurements may also become an impacting factor for differential diagnoses and for designing new research studies.
Chung, King
2012-06-01
Wind noise reduction is a topic of ongoing research and development for hearing aids and cochlear implants. The purposes of this study were to examine spectral characteristics of wind noise generated by directional (DIR) and omnidirectional (OMNI) microphones on different styles of hearing aids and to derive wind noise reduction strategies. Three digital hearing aids (BTE, ITE, and ITC) were fitted to Knowles Electronic Manikin for Acoustic Research. They were programmed to have linear amplification and matching frequency responses between the DIR and OMNI modes. Flow noise recordings were made from 0° to 360° azimuths at flow velocities of 4.5, 9.0, and 13.5 m/s in a quiet wind tunnel. Noise levels were analyzed in one-third octave bands from 100 to 8000 Hz. Comparison of wind noise revealed that DIR generally produced higher noise levels than OMNI for all hearing aids, but it could result in lower levels than OMNI at some frequencies and head angles. Wind noise reduction algorithms can be designed to detect noise levels of DIR and OMNI outputs in each frequency channel, remove the constraint to switch to OMNI in low-frequency channel(s) only, and adopt the microphone mode with lower noise levels to take advantage of the microphone differences.
Effect of current stimulus on in vivo cochlear mechanics
NASA Astrophysics Data System (ADS)
Parthasarathi, Anand A.; Grosh, Karl; Zheng, Jiefu; Nuttall, Alfred L.
2003-01-01
In this paper, the influence of direct current stimulation on the acoustic impulse response of the basilar membrane (BM) is studied. A positive current applied in the scala vestibuli relative to a ground electrode in the scala tympani is found to enhance gain and increase the best frequency at a given location on the BM. An opposite effect is found for a negative current. Also, the amplitude of low-frequency cochlear microphonic at high sound levels is found to change with the concurrent application of direct current stimulus. BM vibrations in response to pure tone acoustic excitation are found to possess harmonics whose levels relative to the fundamental increase with the application of positive current and decrease with the application of negative current. A model for outer hair cell activity that couples changes in length and stiffness to transmembrane potential is used to interpret the results of these experiments and others in the literature. The importance of the in vivo mechanical and electrical loading is emphasized. Simulation results show the somewhat paradoxical finding that for outer hair cells under tension, hyperpolarization causes shortening of the cell length due to the dominance of voltage dependent stiffness changes.
Lai, Ying-Hui; Chen, Fei; Wang, Syu-Siang; Lu, Xugang; Tsao, Yu; Lee, Chin-Hui
2017-07-01
In a cochlear implant (CI) speech processor, noise reduction (NR) is a critical component for enabling CI users to attain improved speech perception under noisy conditions. Identifying an effective NR approach has long been a key topic in CI research. Recently, a deep denoising autoencoder (DDAE) based NR approach was proposed and shown to be effective in restoring clean speech from noisy observations. It was also shown that DDAE could provide better performance than several existing NR methods in standardized objective evaluations. Following this success with normal speech, this paper further investigated the performance of DDAE-based NR to improve the intelligibility of envelope-based vocoded speech, which simulates speech signal processing in existing CI devices. We compared the performance of speech intelligibility between DDAE-based NR and conventional single-microphone NR approaches using the noise vocoder simulation. The results of both objective evaluations and listening test showed that, under the conditions of nonstationary noise distortion, DDAE-based NR yielded higher intelligibility scores than conventional NR approaches. This study confirmed that DDAE-based NR could potentially be integrated into a CI processor to provide more benefits to CI users under noisy conditions.
Imaging extracellular calcium in endolymph
NASA Astrophysics Data System (ADS)
Strimbu, C. Elliott; Fridberger, Anders
2018-05-01
Hair cell mechanoelectrical transduction and adaptation are believed to be regulated by extracellular calcium. However, the majority of experiments addressing calcium's role have been performed on reduced preparations in conditions that do not mimic those present in vivo. We used confocal microscopy and a low affinity (kd ˜11 µM) ratiometric fluorescent indicator to measure the extracellular calcium concentration in scala media in an in vitro preparation of the guinea pig cochlea. Microelectrodes were used to measure the cochlear microphonic potential during acoustic stimulation. The mean calcium concentration is significantly higher in the tectorial membrane (TM) than the surrounding endolymph, suggesting that the membrane acts as a calcium sink. We also observe calcium hot spots along the underside of the TM, near the outer hair cell bundles and near Hensens stripe close to the inner hair cell bundle. This suggests that the local calcium concentration near the hair bundles exceeds 100 µM, significantly higher than the bulk endolymph. These results were corroborated with fluorescence correlation spectroscopy using a second calcium sensitive dye, Oregon Green 488-BAPTA. Following a brief exposure to loud sound, TM calcium drops dramatically and shows recovery on a similar timescale as the microphonic potential. Our results suggest that the extracellular calcium concentration near the hair bundles is much higher than previously believed and may also serve as a partial control parameter for temporary threshold shifts.
Lefebvre, Philippe P.; Gisbert, Javier; Cuda, Domenico; Tringali, Stéphane; Deveze, Arnaud
2017-01-01
Objective To summarise treatment outcomes compared to surgical and patient variables for a multicentre recipient cohort using a fully implantable active middle ear implant for hearing impairment. To describe the authors' preferred surgical technique to determine microphone placement. Study Design Multicentre retrospective, observational survey. Setting Five tertiary referral centres. Patients Carina recipients (66 ears, 62 subjects) using the current Cochlear® Carina® System or the legacy device, the Otologics® Fully Implantable Middle Ear, with a T2 transducer. Methods Patient file review and routine clinical review. Patient outcomes assessed were satisfaction, daily use and feedback reports at the first fitting and ≥12 months after implantation. Descriptive and statistical analysis of correlations of variables and their influence on outcomes was performed. Independently reported preferred methods for microphone placement are collectively summarised. Results The average implant experience was 3.5 years. Satisfaction increased significantly over time (p < 0.05). No correlation with covariates examined was observed. Feedback significantly decreased over time, showing a significant correlation with microphone location, primary motivation, gender, age at implantation, and contralateral hearing aid use (p < 0.05). Patient satisfaction was inversely correlated with reports of system feedback (p < 0.05). The implantable microphone was most commonly on the posterior inferior mastoid line, in 42/66 (65%) cases, correlating with less likelihood for feedback and consistent with author surgical preference. Conclusion Carina recipients in this study present as satisfied consistent daily users with very few reports of persistent feedback. As microphone location is an influencing factor, a careful surgical consideration of microphone placement is required. The authors prefer a posterior inferior mastoid line position whenever possible. PMID:28052264
Feasible pickup from intact ossicular chain with floating piezoelectric microphone.
Kang, Hou-Yong; Na, Gao; Chi, Fang-Lu; Jin, Kai; Pan, Tie-Zheng; Gao, Zhen
2012-02-22
Many microphones have been developed to meet with the implantable requirement of totally implantable cochlear implant (TICI). However, a biocompatible one without destroying the intactness of the ossicular chain still remains under investigation. Such an implantable floating piezoelectric microphone (FPM) has been manufactured and shows an efficient electroacoustic performance in vitro test at our lab. We examined whether it pick up sensitively from the intact ossicular chain and postulated whether it be an optimal implantable one. Animal controlled experiment: five adult cats (eight ears) were sacrificed as the model to test the electroacoustic performance of the FPM. Three groups were studied: (1) the experiment group (on malleus): the FPM glued onto the handle of the malleus of the intact ossicular chains; (2) negative control group (in vivo): the FPM only hung into the tympanic cavity; (3) positive control group (Hy-M30): a HiFi commercial microphone placed close to the site of the experiment ear. The testing speaker played pure tones orderly ranged from 0.25 to 8.0 kHz. The FPM inside the ear and the HiFi microphone simultaneously picked up acoustic vibration which recorded as .wav files to analyze. The FPM transformed acoustic vibration sensitively and flatly as did the in vitro test across the frequencies above 2.0 kHz, whereas inefficiently below 1.0 kHz for its overloading mass. Although the HiFi microphone presented more efficiently than the FPM did, there was no significant difference at 3.0 kHz and 8.0 kHz. It is feasible to develop such an implantable FPM for future TICIs and TIHAs system on condition that the improvement of Micro Electromechanical System and piezoelectric ceramic material technology would be applied to reduce its weight and minimize its size.
[Influence of mixing ratios of a FM-system on speech understanding of CI-users].
Hey, M; Anft, D; Hocke, T; Scholz, G; Hessel, H; Begall, K
2009-05-01
At school we find two major acoustic situations: (first) the "teacher is talking" being disturbed by the pupils making noise and (second) another "pupil is talking" disturbed by other pupils. The understanding of words and sentences in hearing impaired patients with a cochlear implant (CI) in a noisy situation can be improved by using a FM system. The aim of this study is to test speech understanding depending on mixing ratios between FM input and microphone input to the speech processor in different circumstances. Speech understanding was evaluated using the adaptive Oldenburger sentence test (OLSA) in background noise. CI patients used the FM system Microlink for Freedom CIs together with a Campus transmitter (Phonak AG). 17 postlingually deafened adults were tested, using unilateral Freedom cochlear implant systems (Cochlear Ltd). A group of eight normally hearing adults was used as a control group in the same setup. We found that the median value of L (50)=1.6 dB in CI patients without a FM system is higher than the median value of L(50)=-13 dB in normally hearing subjects. The sentence recognition in CI patients with FM system increased with increasing mixing ratio. The benefit using the FM system to understand the teacher is of high advantage in any mixing ratio. The difference between the L(50) values in situations with or without a FM-system is 15 dB for the mixing ratio 3:1 (FM to microphone). If we take into account an increase of 15% per dB in the OLSA (at L(50)) in CI patients, the difference of 15 dB means a calculated advantage of 225%. The speech understanding during the second condition ("pupil is talking") however remained nearly the same in all used mixing ratios. The calculations showed no statistical difference between these situations with and without a FM system. The speaker comprehension for the two investigated listening conditions showed different results. Understanding in the "teacher is talking" situation increased with increasing mixing ratio (FM to microphone) and in the "pupil is talking" situation remained on the same level. We could not find an optimal FM setting for both listening conditions. This leads to different suggestions for different listening conditions. All patients showed an increased speech understanding in noisy environments. This result strongly encourages the use of a FM-system in a classroom.
Kirk, D L; Yates, G K
1998-09-01
Electrically evoked oto-acoustic emissions (EEOAEs) are sounds present in the ear canal when ac current is passed into the cochlea. EEOAEs are attributed to the activation of fast electromotile responses in outer hair cells (OHCs). An interesting property of EEOAEs is the phenomenon of "acoustic enhancement," where the emission amplitude is increased by moderate-level sound [D. C. Mountain and A. E. Hubbard, Hear. Res. 42, 195-202 (1989)]. In this report a form of enhancement is described which occurs with displacements of the basilar membrane toward scala vestibuli, during amplitude modulation of the EEOAE waveform by low-frequency tones. This "SV-bias enhancement" possibly consists of two components: (i) a low-level component induced by sound at levels which produce nonlinear growth of the cochlear microphonic and which may be equivalent to the "acoustic enhancement" described previously, and (ii) a high-level component which occurs at sound levels well above those which cause saturation of the cochlear microphonic. The low-level component could be explained by either an increased access of the extrinsically applied current to a membrane-based source of OHC motility, perhaps coupled with a reduction in negative feedback, or an increase in electromotile output during scala vestibuli displacements, but the origin of the high-level component is obscure.
Skinner, Liam J; Beurg, Maryline; Mitchell, Timothy J; Darrouzet, Vincent; Aran, Jean-Marie; Dulon, Didier
2004-11-01
Bacterial meningitis and chronic suppurative otitis media caused by Streptococcus pneumoniae are associated with considerable otological morbidity. Specifically, sensorineural hearing loss is a permanent sequela in a third of those who contract pneumococcal meningitis. Pneumolysin, a pneumococcal protein, has been implicated as one of the main virulence/cytotoxic factors. Its pathogenicity is intimately dependent on an ability to form transmembrane pores on binding with cholesterol in target tissues. We perfused wild-type pneumolysin, at a number of different concentrations, into the guinea pig cochlea and used electrocochleography to characterize the effects of this cytolytic exotoxin in the organ of Corti. Intracochlear perfusion of pneumolysin (10 microg/50 microl) reduced the compound action potential of the auditory nerve within seconds. The cochlear microphonics (f1=8 kHz, f2=9.68 kHz) and their distortion product (2f1-f2) were also reduced, albeit in a slightly less dramatic fashion. At lower concentrations (1 microg/50 microl), a selective and earlier effect on inner hair cells was observed. These results clearly show that significant ototoxicity ensues when sensory cells of the organ of Corti are exposed to pneumolysin (and complete cochlear death when the concentration is high enough). Toxicity is dose-dependent and appears to be site-sensitive. This may have implications for any possible future protective strategies against pneumococcal disease in the ear.
Liu, Ke; Ji, Fei; Yang, Guan; Hou, Zhaohui; Sun, Jianhe; Wang, Xiaoyu; Guo, Weiwei; Sun, Wei; Yang, Weiyan; Yang, Xiao; Yang, Shiming
2016-10-01
More than 100 genes have been associated with deafness. However, SMAD4 is rarely considered a contributor to deafness in humans, except for its well-defined role in cell differentiation and regeneration. Here, we report that a SMAD4 defect in mice can cause auditory neuropathy, which was defined as a mysterious hearing and speech perception disorder in human for which the genetic background remains unclear. Our study showed that a SMAD4 defect induces failed formation of cochlear ribbon synapse during the earlier stage of auditory development in mice. Further investigation found that there are nearly normal morphology of outer hair cells (OHCs) and post-synapse spiral ganglion nerves (SGNs) in SMAD4 conditional knockout mice (cKO); however, a preserved distortion product of otoacoustic emission (DPOAE) and cochlear microphonic (CM) still can be evoked in cKO mice. Moreover, a partial restoration of hearing detected by electric auditory brainstem response (eABR) has been obtained in the cKO mice using electrode stimuli toward auditory nerves. Additionally, the ribbon synapses in retina are not affected by this SMAD4 defect. Thus, our findings suggest that this SMAD4 defect causes auditory neuropathy via specialized disruption of cochlear ribbon synapses.
MEMS capacitive accelerometer-based middle ear microphone.
Young, Darrin J; Zurcher, Mark A; Semaan, Maroun; Megerian, Cliff A; Ko, Wen H
2012-12-01
The design, implementation, and characterization of a microelectromechanical systems (MEMS) capacitive accelerometer-based middle ear microphone are presented in this paper. The microphone is intended for middle ear hearing aids as well as future fully implantable cochlear prosthesis. Human temporal bones acoustic response characterization results are used to derive the accelerometer design requirements. The prototype accelerometer is fabricated in a commercial silicon-on-insulator (SOI) MEMS process. The sensor occupies a sensing area of 1 mm × 1 mm with a chip area of 2 mm × 2.4 mm and is interfaced with a custom-designed low-noise electronic IC chip over a flexible substrate. The packaged sensor unit occupies an area of 2.5 mm × 6.2 mm with a weight of 25 mg. The sensor unit attached to umbo can detect a sound pressure level (SPL) of 60 dB at 500 Hz, 35 dB at 2 kHz, and 57 dB at 8 kHz. An improved sound detection limit of 34-dB SPL at 150 Hz and 24-dB SPL at 500 Hz can be expected by employing start-of-the-art MEMS fabrication technology, which results in an articulation index of approximately 0.76. Further micro/nanofabrication technology advancement is needed to enhance the microphone sensitivity for improved understanding of normal conversational speech.
A MEMS Condenser Microphone-Based Intracochlear Acoustic Receiver.
Pfiffner, Flurin; Prochazka, Lukas; Peus, Dominik; Dobrev, Ivo; Dalbert, Adrian; Sim, Jae Hoon; Kesterke, Rahel; Walraevens, Joris; Harris, Francesca; Roosli, Christof; Obrist, Dominik; Huber, Alexander
2017-10-01
Intracochlear sound pressure (ICSP) measurements are limited by the small dimensions of the human inner ear and the requirements imposed by the liquid medium. A robust intracochlear acoustic receiver (ICAR) for repeated use with a simple data acquisition system that provides the required high sensitivity and small dimensions does not yet exist. The work described in this report aims to fill this gap and presents a new microelectromechanical systems (MEMS) condenser microphone (CMIC)-based ICAR concept suitable for ICSP measurements in human temporal bones. The ICAR head consisted of a passive protective diaphragm (PD) sealing the MEMS CMIC against the liquid medium, enabling insertion into the inner ear. The components of the MEMS CMIC-based ICAR were expressed by a lumped element model (LEM) and compared to the performance of successfully fabricated ICARs. Good agreement was achieved between the LEM and the measurements with different sizes of the PD. The ICSP measurements in a human cadaver temporal bone yielded data in agreement with the literature. Our results confirm that the presented MEMS CMIC-based ICAR is a promising technology for measuring ICSP in human temporal bones in the audible frequency range. A sensor for evaluation of the biomechanical hearing process by quantification of ICSP is presented. The concept has potential as an acoustic receiver in totally implantable cochlear implants.
Future technology in cochlear implants: assessing the benefit.
Briggs, Robert J S
2011-05-01
It has been over 50 years since Djourno and Eyries first attempted electric stimulation in a patient with deafness. Over this time, the Cochlear Implant (CI) has become not only remarkably successful, but increasingly complex. Although the basic components of the system still comprise an implanted receiver stimulator and electrode, externally worn speech processor, microphone, control system, and power source, there are now several alternative designs of these components with different attributes that can be variably combined to meet the needs of specific patient groups. Development by the manufacturers has been driven both by these various patient needs, and also by the desire to achieve technological superiority, or at least differentiation, ultimately in pursuit of market share. Assessment of benefit is the responsibility of clinicians. It is incumbent on both industry and clinicians to ensure appropriate, safe, and affordable introduction of new technology. For example, experience with the totally implanted cochlear implant (TIKI) has demonstrated that quality of hearing is the over-riding consideration for CI users. To date, improved hearing outcomes have been achieved by improvements in: speech processing strategies; microphone technology; pre-processing strategies; electrode placement; bilateral implantation; use of a hearing aid in the opposite ear (bimodal stimulation); and the combination of electric and acoustic stimulation in the same ear. The resulting expansion of CI candidacy, with more residual hearing, further improves the outcomes achieved. Largely facilitated by advances in electronic capability and computerization, it can be expected that these improvements will continue. However, marked variability of results still occurs and we cannot assure any individual patient of their outcome. Realistic goals for implementation of new technology include: improved hearing in noise and music perception; effective invisible hearing (no external apparatus); automated fitting; and reduction in outcome variability. This paper provides examples of relevant potential future technologies that can be applied to reach these goals. In the quest for better outcomes, future technology must deliver improved reliability and usability for both clinicians and recipients that does not compromise safety and is affordable. One of the challenges related to the introduction of new technologies is the 'classification' of CI systems and the framework under which sufficient change and increased benefit can be demonstrated to establish a claim of 'new generation CI' and hence increased reimbursement from third-party payers. Significant improvements in hearing outcomes and quality of life associated with CI design changes are difficult to measure, particularly when there is such dramatic benefit from the intervention of cochlear implantation from the individual's perspective. Manufacturers and clinicians need to be objective and undertake appropriate safety studies and long-term and multi-centre clinical trials to ensure that the introduction of new technology is both safe and effective and supported by health systems worldwide.
[Cochlear implant in children: rational, indications and cost/efficacy].
Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S
2013-06-01
A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long this advantage persists in the subsequent years. With regard to cochlear implantation in children older than 12 months the studies show better hearing and linguistic results in children implanted at earlier ages. A sensitive period under 24-36 months has been identified over which cochlear implantation is reported to be less effective in terms of improvement in speech and hearing results. With regard to clinical effectiveness of bilateral cochlear implantation, greater benefits from bilateral implants compared to monolateral ones when assessing hearing in quiet and in noise and in sound localization abilities are reported to be present in both case of simultaneous or sequential bilateral implantation. However, with regard to the delay between the surgeries in sequential bilateral implantation, although benefit is reported to be present even after very long delays, on average long delays between surgeries seems to negatively affect the outcome with the second implant. With regard to benefits after cochlear implantation in children with multiple disabilities, benefits in terms of speech perception and communication as well as in quality of the daily life are reported even if benefits are slower and lower in comparison to those generally attained by implanted children without additional disabilities. Regarding the costs/efficacy ratio, the CI is expensive, in particular because of the cost of the high technological device, long life support, but even if healthcare costs are high, the savings in terms of indirect costs and quality of life are important. The CI, in fact, has a positive impact in terms of quality of life.
Improving Speech Perception in Noise with Current Focusing in Cochlear Implant Users
Srinivasan, Arthi G.; Padilla, Monica; Shannon, Robert V.; Landsberger, David M.
2013-01-01
Cochlear implant (CI) users typically have excellent speech recognition in quiet but struggle with understanding speech in noise. It is thought that broad current spread from stimulating electrodes causes adjacent electrodes to activate overlapping populations of neurons which results in interactions across adjacent channels. Current focusing has been studied as a way to reduce spread of excitation, and therefore, reduce channel interactions. In particular, partial tripolar stimulation has been shown to reduce spread of excitation relative to monopolar stimulation. However, the crucial question is whether this benefit translates to improvements in speech perception. In this study, we compared speech perception in noise with experimental monopolar and partial tripolar speech processing strategies. The two strategies were matched in terms of number of active electrodes, microphone, filterbanks, stimulation rate and loudness (although both strategies used a lower stimulation rate than typical clinical strategies). The results of this study showed a significant improvement in speech perception in noise with partial tripolar stimulation. All subjects benefited from the current focused speech processing strategy. There was a mean improvement in speech recognition threshold of 2.7 dB in a digits in noise task and a mean improvement of 3 dB in a sentences in noise task with partial tripolar stimulation relative to monopolar stimulation. Although the experimental monopolar strategy was worse than the clinical, presumably due to different microphones, frequency allocations and stimulation rates, the experimental partial-tripolar strategy, which had the same changes, showed no acute deficit relative to the clinical. PMID:23467170
Adiloğlu, K.; Herzke, T.
2015-01-01
We present the first portable, binaural, real-time research platform compatible with Oticon Medical SP and XP generation cochlear implants. The platform consists of (a) a pair of behind-the-ear devices, each containing front and rear calibrated microphones, (b) a four-channel USB analog-to-digital converter, (c) real-time PC-based sound processing software called the Master Hearing Aid, and (d) USB-connected hardware and output coils capable of driving two implants simultaneously. The platform is capable of processing signals from the four microphones simultaneously and producing synchronized binaural cochlear implant outputs that drive two (bilaterally implanted) SP or XP implants. Both audio signal preprocessing algorithms (such as binaural beamforming) and novel binaural stimulation strategies (within the implant limitations) can be programmed by researchers. When the whole research platform is combined with Oticon Medical SP implants, interaural electrode timing can be controlled on individual electrodes to within ±1 µs and interaural electrode energy differences can be controlled to within ±2%. Hence, this new platform is particularly well suited to performing experiments related to interaural time differences in combination with interaural level differences in real-time. The platform also supports instantaneously variable stimulation rates and thereby enables investigations such as the effect of changing the stimulation rate on pitch perception. Because the processing can be changed on the fly, researchers can use this platform to study perceptual changes resulting from different processing strategies acutely. PMID:26721923
Backus, B; Adiloğlu, K; Herzke, T
2015-12-30
We present the first portable, binaural, real-time research platform compatible with Oticon Medical SP and XP generation cochlear implants. The platform consists of (a) a pair of behind-the-ear devices, each containing front and rear calibrated microphones, (b) a four-channel USB analog-to-digital converter, (c) real-time PC-based sound processing software called the Master Hearing Aid, and (d) USB-connected hardware and output coils capable of driving two implants simultaneously. The platform is capable of processing signals from the four microphones simultaneously and producing synchronized binaural cochlear implant outputs that drive two (bilaterally implanted) SP or XP implants. Both audio signal preprocessing algorithms (such as binaural beamforming) and novel binaural stimulation strategies (within the implant limitations) can be programmed by researchers. When the whole research platform is combined with Oticon Medical SP implants, interaural electrode timing can be controlled on individual electrodes to within ±1 µs and interaural electrode energy differences can be controlled to within ±2%. Hence, this new platform is particularly well suited to performing experiments related to interaural time differences in combination with interaural level differences in real-time. The platform also supports instantaneously variable stimulation rates and thereby enables investigations such as the effect of changing the stimulation rate on pitch perception. Because the processing can be changed on the fly, researchers can use this platform to study perceptual changes resulting from different processing strategies acutely. © The Author(s) 2015.
Cochlear perfusion with a viscous fluid.
Wang, Yi; Olson, Elizabeth S
2016-07-01
The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawn from basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner's membrane (RM), while in cochleae perfused with 0.125% and 0.25% HA RM was torn. Thus, the CAP threshold elevation was likely due to the broken RM, likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and then clearance of viscous fluid within the cochlea, or to a temporary position shift of the Organ of Corti. After 0.5% HA perfusion, a short latency positive peak (P0) appeared in the CAP waveform. This P0 might be due to a change in the cochlea's traveling-wave pattern, or distortion in the cochlear microphonic. Copyright © 2016 Elsevier B.V. All rights reserved.
Cochlear perfusion with a viscous fluid
Wang, Yi; Olson, Elizabeth S.
2016-01-01
The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawnfrom basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner’s membrane, while in cochleae perfused with 0.125% and 0.25% HA Reissner’s membrane (RM) was torn. Thus, the CAP threshold elevation was likely due to the broken of RM, which likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and then clearance of viscous fluid within the cochlea, or to a temporary position shift of the Organ of Corti. After 0.5% HA perfusion, a short latency positive peak (P0) appeared in the CAP wavefrom. This P0 might be due to a change in the cochlea’s traveling-wave pattern, or distortion in the cochlear microphonic. PMID:27220484
Geng, Ruishuang; Melki, Sami; Chen, Daniel H.-C.; Tian, Guilian; Furness, David; Oshima-Takago, Tomoko; Neef, Jakob; Moser, Tobias; Askew, Charles; Horwitz, Geoff; Holt, Jeffrey; Imanishi, Yoshikazu; Alagramam, Kumar N.
2012-01-01
Mutation in the clarin-1 gene results in loss of hearing and vision in humans (Usher syndrome III), but the role of clarin-1 in the sensory hair cells is unknown. Clarin-1 is predicted to be a four transmembrane domain protein similar to members of the tetraspanin family. Mice carrying null mutation in the clarin-1 (Clrn1−/−) gene show loss of hair cell function and a possible defect in ribbon synapse. We investigated the role of clarin-1 using various in vitro and in vivo approaches. We show by immunohistochemistry and patch-clamp recordings of Ca2+ currents and membrane capacitance from IHCs that clarin-1 is not essential for formation or function of ribbon synapse. However, reduced cochlear microphonic potentials, FM1-43 loading and transduction currents pointed to diminished cochlear hair bundle function in Clrn1−/− mice. Electron microscopy of cochlear hair cells revealed loss of some tall stereocilia and gaps in the v-shaped bundle, although tip-links and staircase arrangement of stereocilia were not primarily affected by Clrn1−/− mutation. Human clarin-1 protein expressed in transfected mouse cochlear hair cells localized to the bundle; however, the pathogenic variant, p.N48K, failed to localize to the bundle. The mouse model generated to study the in vivo consequence of p. N48K in clarin-1 (Clrn1N48K) supports our in vitro and Clrn1−/− mouse data and the conclusion that CLRN1 is an essential hair bundle protein. Further, the ear phenotype in the Clrn1N48K mouse suggests that it is a valuable model for ear disease in CLRN1N48K, the most prevalent Usher III mutation in North America. PMID:22787034
Geng, Ruishuang; Melki, Sami; Chen, Daniel H-C; Tian, Guilian; Furness, David N; Oshima-Takago, Tomoko; Neef, Jakob; Moser, Tobias; Askew, Charles; Horwitz, Geoff; Holt, Jeffrey R; Imanishi, Yoshikazu; Alagramam, Kumar N
2012-07-11
Mutation in the clarin-1 gene (Clrn1) results in loss of hearing and vision in humans (Usher syndrome III), but the role of clarin-1 in the sensory hair cells is unknown. Clarin-1 is predicted to be a four transmembrane domain protein similar to members of the tetraspanin family. Mice carrying null mutation in the clarin-1 gene (Clrn1(-/-)) show loss of hair cell function and a possible defect in ribbon synapse. We investigated the role of clarin-1 using various in vitro and in vivo approaches. We show by immunohistochemistry and patch-clamp recordings of Ca(2+) currents and membrane capacitance from inner hair cells that clarin-1 is not essential for formation or function of ribbon synapse. However, reduced cochlear microphonic potentials, FM1-43 [N-(3-triethylammoniumpropyl)-4-(4-(dibutylamino)styryl) pyridinium dibromide] loading, and transduction currents pointed to diminished cochlear hair bundle function in Clrn1(-/-) mice. Electron microscopy of cochlear hair cells revealed loss of some tall stereocilia and gaps in the v-shaped bundle, although tip links and staircase arrangement of stereocilia were not primarily affected by Clrn1(-/-) mutation. Human clarin-1 protein expressed in transfected mouse cochlear hair cells localized to the bundle; however, the pathogenic variant p.N48K failed to localize to the bundle. The mouse model generated to study the in vivo consequence of p.N48K in clarin-1 (Clrn1(N48K)) supports our in vitro and Clrn1(-/-) mouse data and the conclusion that CLRN1 is an essential hair bundle protein. Furthermore, the ear phenotype in the Clrn1(N48K) mouse suggests that it is a valuable model for ear disease in CLRN1(N48K), the most prevalent Usher syndrome III mutation in North America.
Hu, Ning; Du, Xiaoping; Li, Wei; West, Matthew B.; Choi, Chul-Hee; Floyd, Robert; Kopke, Richard D.
2017-01-01
Oxidative stress is considered a major cause of the structural and functional changes associated with auditory pathologies induced by exposure to acute acoustic trauma AAT). In the present study, we examined the otoprotective effects of 2,4-disulfophenyl-N-tert-butylnitrone (HPN-07), a nitrone-based free radical trap, on the physiological and cellular changes in the auditory system of chinchilla following a six-hour exposure to 4 kHz octave band noise at 105 dB SPL. HPN-07 has been shown to suppress oxidative stress in biological models of a variety of disorders. Our results show that administration of HPN-07 beginning four hours after acoustic trauma accelerated and enhanced auditory/cochlear functional recovery, as measured by auditory brainstem responses (ABR), distortion product otoacoustic emissions (DPOAE), compound action potentials (CAP), and cochlear microphonics (CM). The normally tight correlation between the endocochlear potential (EP) and evoked potentials of CAP and CM were persistently disrupted after noise trauma in untreated animals but returned to homeostatic conditions in HPN-07 treated animals. Histological analyses revealed several therapeutic advantages associated with HPN-07 treatment following AAT, including reductions in inner and outer hair cell loss; reductions in AAT-induced loss of calretinin-positive afferent nerve fibers in the spiral lamina; and reductions in fibrocyte loss within the spiral ligament. These findings support the conclusion that early intervention with HPN-07 following an AAT efficiently blocks the propagative ototoxic effects of oxidative stress, thereby preserving the homeostatic and functional integrity of the cochlea. PMID:28832600
A Series of Case Studies of Tinnitus Suppression With Mixed Background Stimuli in a Cochlear Implant
Keiner, A. J.; Walker, Kurt; Deshpande, Aniruddha K.; Witt, Shelley; Killian, Matthijs; Ji, Helena; Patrick, Jim; Dillier, Norbert; van Dijk, Pim; Lai, Wai Kong; Hansen, Marlan R.; Gantz, Bruce
2015-01-01
Purpose Background sounds provided by a wearable sound playback device were mixed with the acoustical input picked up by a cochlear implant speech processor in an attempt to suppress tinnitus. Method First, patients were allowed to listen to several sounds and to select up to 4 sounds that they thought might be effective. These stimuli were programmed to loop continuously in the wearable playback device. Second, subjects were instructed to use 1 background sound each day on the wearable device, and they sequenced the selected background sounds during a 28-day trial. Patients were instructed to go to a website at the end of each day and rate the loudness and annoyance of the tinnitus as well as the acceptability of the background sound. Patients completed the Tinnitus Primary Function Questionnaire (Tyler, Stocking, Secor, & Slattery, 2014) at the beginning of the trial. Results Results indicated that background sounds were very effective at suppressing tinnitus. There was considerable variability in sounds preferred by the subjects. Conclusion The study shows that a background sound mixed with the microphone input can be effective for suppressing tinnitus during daily use of the sound processor in selected cochlear implant users. PMID:26001407
Hunter, Lisa L; Blankenship, Chelsea M; Gunter, Rebekah G; Keefe, Douglas H; Feeney, M Patrick; Brown, David K; Baroch, Kelly
2018-05-01
Examination of cochlear and neural potentials is necessary to assess sensory and neural status in infants, especially those cared for in neonatal intensive care units (NICU) who have high rates of hyperbilirubinemia and thus are at risk for auditory neuropathy (AN). The purpose of this study was to determine whether recording parameters commonly used in click-evoked auditory brain stem response (ABR) are useful for recording cochlear microphonic (CM) and Wave I in infants at risk for AN. Specifically, we analyzed CM, summating potential (SP), and Waves I, III, and V. The overall aim was to compare latencies and amplitudes of evoked responses in infants cared for in NICUs with infants in a well-baby nursery (WBN), both of which passed newborn hearing screening. This is a prospective study in which infants who passed ABR newborn hearing screening were grouped based on their birth history (WBN and NICU). All infants had normal hearing status when tested with diagnostic ABR at about one month of age, corrected for prematurity. Thirty infants (53 ears) from the WBN [mean corrected age at test = 5.0 weeks (wks.)] and thirty-two infants (59 ears) from the NICU (mean corrected age at test = 5.7 wks.) with normal hearing were included in this study. In addition, two infants were included as comparative case studies, one that was diagnosed with AN and another case that was diagnosed with bilateral sensorineural hearing loss (SNHL). Diagnostic ABR, including click and tone-burst air- and bone-conduction stimuli were recorded. Peak Waves I, III, and V; SP; and CM latency and amplitude (peak to trough) were measured to determine if there were differences in ABR and electrocochleography (ECochG) variables between WBN and NICU infants. No significant group differences were found between WBN and NICU groups for ABR waveforms, CM, or SP, including amplitude and latency values. The majority (75%) of the NICU group had hyperbilirubinemia, but overall, they did not show evidence of effects in their ECochG or ABR responses when tested at about one-month corrected age. These data may serve as a normative sample for NICU and well infant ECochG and ABR latencies at one-month corrected age. Two infant case studies, one diagnosed with AN and another with SNHL demonstrated the complexity of using ECochG and otoacoustic emissions to assess the risk of AN in individual cases. CM and SPs can be readily measured using standard click stimuli in both well and NICU infants. Normative ranges for latency and amplitude are useful for interpreting ECochG and ABR components. Inclusion of ECochG and ABR tests in a test battery that also includes otoacoustic emission and acoustic reflex tests may provide a more refined assessment of the risks of AN and SNHL in infants. American Academy of Audiology.
Comparing Binaural Pre-processing Strategies II
Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias
2015-01-01
Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. PMID:26721921
Lopez, Esteban Alejandro; Costa, Orozimbo Alves; Ferrari, Deborah Viviane
2016-10-01
The purpose of this research note is to describe the development and technical validation of the Mobile Based Assistive Listening System (MoBALS), a free-of-charge smartphone-based remote microphone application. MoBALS Version 1.0 was developed for Android (Version 2.1 or higher) and was coded with Java using Eclipse Indigo with the Android Software Development Kit. A Wi-Fi router with background traffic and 2 affordable smartphones were used for debugging and technical validation comprising, among other things, multicasting capability, data packet loss, and battery consumption. MoBALS requires at least 2 smartphones connected to the same Wi-Fi router for signal transmission and reception. Subscriber identity module cards or Internet connections are not needed. MoBALS can be used alone or connected to a hearing aid or cochlear implant via direct audio input. Maximum data packet loss was 99.28%, and minimum battery life was 5 hr. Other relevant design specifications and their implementation are described. MoBALS performed as a remote microphone with enhanced accessibility features and avoids overhead expenses by using already-available and affordable technology. The further development and technical revalidation of MoBALS will be followed by clinical evaluation with persons with hearing impairment.
Improving speech perception in noise with current focusing in cochlear implant users.
Srinivasan, Arthi G; Padilla, Monica; Shannon, Robert V; Landsberger, David M
2013-05-01
Cochlear implant (CI) users typically have excellent speech recognition in quiet but struggle with understanding speech in noise. It is thought that broad current spread from stimulating electrodes causes adjacent electrodes to activate overlapping populations of neurons which results in interactions across adjacent channels. Current focusing has been studied as a way to reduce spread of excitation, and therefore, reduce channel interactions. In particular, partial tripolar stimulation has been shown to reduce spread of excitation relative to monopolar stimulation. However, the crucial question is whether this benefit translates to improvements in speech perception. In this study, we compared speech perception in noise with experimental monopolar and partial tripolar speech processing strategies. The two strategies were matched in terms of number of active electrodes, microphone, filterbanks, stimulation rate and loudness (although both strategies used a lower stimulation rate than typical clinical strategies). The results of this study showed a significant improvement in speech perception in noise with partial tripolar stimulation. All subjects benefited from the current focused speech processing strategy. There was a mean improvement in speech recognition threshold of 2.7 dB in a digits in noise task and a mean improvement of 3 dB in a sentences in noise task with partial tripolar stimulation relative to monopolar stimulation. Although the experimental monopolar strategy was worse than the clinical, presumably due to different microphones, frequency allocations and stimulation rates, the experimental partial-tripolar strategy, which had the same changes, showed no acute deficit relative to the clinical. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhang, Ming
2014-07-01
Compared to auditory brainstem responses (ABRs), cochlear microphonics (CMs) may be more appropriate to serve as a supplement to the test of otoacoustic emissions (OAEs). Researchers have shown that low-frequency CMs from the apical cochlea are measurable at the tympanic membrane using high-pass masking noise. Our objective is to study the effect of such noise at different intensities on low-frequency CMs recorded at the ear canal, which is not completely known. Six components were involved in this CM measurement including an ear canal electrode (1), a relatively long and low-frequency toneburst (2), and high-pass masking noise at different intensities (3). The rest components include statistical analysis based on multiple human subjects (4), curve modeling based on amplitudes of CM waveforms (CMWs) and noise intensity (5), and a technique based on electrocochleography (ECochG or ECoG) (6). Results show that low-frequency CMWs appeared clearly. The CMW amplitude decreased with an increase in noise level. It decreased first slowly, then faster, and finally slowly again. In conclusion, when masked with high-pass noise, the low-frequency CMs are measurable at the human ear canal. Such noise reduces the low-frequency CM amplitude. The reduction is noise-intensity dependent but not completely linear. The reduction may be caused by the excited basal cochlea which the low-frequency has to travel and pass through. Although not completely clear, six mechanisms related to such reduction are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.
De Ceulaer, Geert; Pascoal, David; Vanpoucke, Filiep; Govaerts, Paul J
2017-11-01
The newest Nucleus CI processor, the CP900, has two new options to improve speech-in-noise perception: (1) use of an adaptive directional microphone (SCAN mode) and (2) wireless connection to MiniMic1 and MiniMic2 wireless remote microphones. An analysis was made of the absolute and relative benefits of these technologies in a real-world mimicking test situation. Speech perception was tested using an adaptive speech-in-noise test (sentences-in-babble noise). In session A, SRTs were measured in three conditions: (1) Clinical Map, (2) SCAN and (3) MiniMic1. Each was assessed for three distances between speakers and CI recipient: 1 m, 2 m and 3 m. In session B, the benefit of the use of MiniMic2 was compared to benefit of MiniMic1 at 3 m. A group of 13 adult CP900 recipients participated. SCAN and MiniMic1 improved performance compared to the standard microphone with a median improvement in SRT of 2.7-3.9 dB for SCAN at 1 m and 3 m, respectively, and 4.7-10.9 dB for the MiniMic1. MiniMic1 improvements were significant. MiniMic2 showed an improvement in SRT of 22.2 dB compared to 10.0 dB for MiniMic1 (3 m). Digital wireless transmission systems (i.e. MiniMic) offer a statistically and clinically significant improvement in speech perception in challenging, realistic listening conditions.
Clinical Validation of a Sound Processor Upgrade in Direct Acoustic Cochlear Implant Subjects
Kludt, Eugen; D’hondt, Christiane; Lenarz, Thomas; Maier, Hannes
2017-01-01
Objective: The objectives of the investigation were to evaluate the effect of a sound processor upgrade on the speech reception threshold in noise and to collect long-term safety and efficacy data after 2½ to 5 years of device use of direct acoustic cochlear implant (DACI) recipients. Study Design: The study was designed as a mono-centric, prospective clinical trial. Setting: Tertiary referral center. Patients: Fifteen patients implanted with a direct acoustic cochlear implant. Intervention: Upgrade with a newer generation of sound processor. Main Outcome Measures: Speech recognition test in quiet and in noise, pure tone thresholds, subject-reported outcome measures. Results: The speech recognition in quiet and in noise is superior after the sound processor upgrade and stable after long-term use of the direct acoustic cochlear implant. The bone conduction thresholds did not decrease significantly after long-term high level stimulation. Conclusions: The new sound processor for the DACI system provides significant benefits for DACI users for speech recognition in both quiet and noise. Especially the noise program with the use of directional microphones (Zoom) allows DACI patients to have much less difficulty when having conversations in noisy environments. Furthermore, the study confirms that the benefits of the sound processor upgrade are available to the DACI recipients even after several years of experience with a legacy sound processor. Finally, our study demonstrates that the DACI system is a safe and effective long-term therapy. PMID:28406848
Cochlear transducer operating point adaptation.
Zou, Yuan; Zheng, Jiefu; Ren, Tianying; Nuttall, Alfred
2006-04-01
The operating point (OP) of outer hair cell (OHC) mechanotransduction can be defined as any shift away from the center position on the transduction function. It is a dc offset that can be described by percentage of the maximum transduction current or as an equivalent dc pressure in the ear canal. The change of OP can be determined from the changes of the second and third harmonics of the cochlear microphonic (CM) following a calibration of its initial value. We found that the initial OP was dependent on sound level and cochlear sensitivity. From CM generated by a lower sound level at 74 dB SPL to avoid saturation and suppression of basal turn cochlear amplification, the OHC OP was at constant 57% of the maximum transduction current (an ear canal pressure of -0.1 Pa). To perturb the OP, a constant force was applied to the bony shell of the cochlea at the 18 kHz best frequency location using a blunt probe. The force applied over the scala tympani induced an OP change as if the organ of Corti moved toward the scala vestibuli (SV) direction. During an application of the constant force, the second harmonic of the CM partially recovered toward the initial level, which could be described by two time constants. Removing the force induced recovery of the second harmonic to its normal level described by a single time constant. The force applied over the SV caused an opposite result. These data indicate an active mechanism for OHC transduction OP.
Zou, Junhuang; Zheng, Tihua; Ren, Chongyu; Askew, Charles; Liu, Xiao-Ping; Pan, Bifeng; Holt, Jeffrey R; Wang, Yong; Yang, Jun
2014-05-01
Usher syndrome type 2 (USH2) is the predominant form of USH, a leading genetic cause of combined deafness and blindness. PDZD7, a paralog of two USH causative genes, USH1C and USH2D (WHRN), was recently reported to be implicated in USH2 and non-syndromic deafness. It encodes a protein with multiple PDZ domains. To understand the biological function of PDZD7 and the pathogenic mechanism caused by PDZD7 mutations, we generated and thoroughly characterized a Pdzd7 knockout mouse model. The Pdzd7 knockout mice exhibit congenital profound deafness, as assessed by auditory brainstem response, distortion product otoacoustic emission and cochlear microphonics tests, and normal vestibular function, as assessed by their behaviors. Lack of PDZD7 leads to the disorganization of stereocilia bundles and a reduction in mechanotransduction currents and sensitivity in cochlear outer hair cells. At the molecular level, PDZD7 determines the localization of the USH2 protein complex, composed of USH2A, GPR98 and WHRN, to ankle links in developing cochlear hair cells, likely through its direct interactions with these three proteins. The localization of PDZD7 to the ankle links of cochlear hair bundles also relies on USH2 proteins. In photoreceptors of Pdzd7 knockout mice, the three USH2 proteins largely remain unchanged at the periciliary membrane complex. The electroretinogram responses of both rod and cone photoreceptors are normal in knockout mice at 1 month of age. Therefore, although the organization of the USH2 complex appears different in photoreceptors, it is clear that PDZD7 plays an essential role in organizing the USH2 complex at ankle links in developing cochlear hair cells. GenBank accession numbers: KF041446, KF041447, KF041448, KF041449, KF041450, KF041451.
Wolfe, Jace; Schafer, Erin; Parkinson, Aaron; John, Andrew; Hudson, Mary; Wheeler, Julie; Mucci, Angie
2013-01-01
The objective of this study was to compare speech recognition in quiet and in noise for cochlear implant recipients using two different types of personal frequency modulation (FM) systems (directly coupled [direct auditory input] versus induction neckloop) with each of two sound processors (Cochlear Nucleus Freedom versus Cochlear Nucleus 5). Two different experiments were conducted within this study. In both these experiments, mixing of the FM signal within the Freedom processor was implemented via the same scheme used clinically for the Freedom sound processor. In Experiment 1, the aforementioned comparisons were conducted with the Nucleus 5 programmed so that the microphone and FM signals were mixed and then the mixed signals were subjected to autosensitivity control (ASC). In Experiment 2, comparisons between the two FM systems and processors were conducted again with the Nucleus 5 programmed to provide a more complex multistage implementation of ASC during the preprocessing stage. This study was a within-subject, repeated-measures design. Subjects were recruited from the patient population at the Hearts for Hearing Foundation in Oklahoma City, OK. Fifteen subjects participated in Experiment 1, and 16 subjects participated in Experiment 2. Subjects were adults who had used either unilateral or bilateral cochlear implants for at least 1 year. In this experiment, no differences were found in speech recognition in quiet obtained with the two different FM systems or the various sound-processor conditions. With each sound processor, speech recognition in noise was better with the directly coupled direct auditory input system relative to the neckloop system. The multistage ASC processing of the Nucleus 5 sound processor provided better performance than the single-stage approach for the Nucleus 5 and the Nucleus Freedom sound processor. Speech recognition in noise is substantially affected by the type of sound processor, FM system, and implementation of ASC used by a Cochlear implant recipient.
Absence of both auditory evoked potentials and auditory percepts dependent on timing cues.
Starr, A; McPherson, D; Patterson, J; Don, M; Luxford, W; Shannon, R; Sininger, Y; Tonakawa, L; Waring, M
1991-06-01
An 11-yr-old girl had an absence of sensory components of auditory evoked potentials (brainstem, middle and long-latency) to click and tone burst stimuli that she could clearly hear. Psychoacoustic tests revealed a marked impairment of those auditory perceptions dependent on temporal cues, that is, lateralization of binaural clicks, change of binaural masked threshold with changes in signal phase, binaural beats, detection of paired monaural clicks, monaural detection of a silent gap in a sound, and monaural threshold elevation for short duration tones. In contrast, auditory functions reflecting intensity or frequency discriminations (difference limens) were only minimally impaired. Pure tone audiometry showed a moderate (50 dB) bilateral hearing loss with a disproportionate severe loss of word intelligibility. Those auditory evoked potentials that were preserved included (1) cochlear microphonics reflecting hair cell activity; (2) cortical sustained potentials reflecting processing of slowly changing signals; and (3) long-latency cognitive components (P300, processing negativity) reflecting endogenous auditory cognitive processes. Both the evoked potential and perceptual deficits are attributed to changes in temporal encoding of acoustic signals perhaps occurring at the synapse between hair cell and eighth nerve dendrites. The results from this patient are discussed in relation to previously published cases with absent auditory evoked potentials and preserved hearing.
Click- and chirp-evoked human compound action potentials
Chertoff, Mark; Lichtenhan, Jeffery; Willis, Marie
2010-01-01
In the experiments reported here, the amplitude and the latency of human compound action potentials (CAPs) evoked from a chirp stimulus are compared to those evoked from a traditional click stimulus. The chirp stimulus was created with a frequency sweep to compensate for basilar membrane traveling wave delay using the O-Chirp equations from Fobel and Dau [(2004). J. Acoust. Soc. Am. 116, 2213–2222] derived from otoacoustic emission data. Human cochlear traveling wave delay estimates were obtained from derived compound band action potentials provided by Eggermont [(1979). J. Acoust. Soc. Am. 65, 463–470]. CAPs were recorded from an electrode placed on the tympanic membrane (TM), and the acoustic signals were monitored with a probe tube microphone attached to the TM electrode. Results showed that the amplitude and latency of chirp-evoked N1 of the CAP differed from click-evoked CAPs in several regards. For the chirp-evoked CAP, the N1 amplitude was significantly larger than the click-evoked N1s. The latency-intensity function was significantly shallower for chirp-evoked CAPs as compared to click-evoked CAPs. This suggests that auditory nerve fibers respond with more unison to a chirp stimulus than to a click stimulus. PMID:21117748
NASA Astrophysics Data System (ADS)
Mistrík, Pavel; Ashmore, Jonathan
2009-02-01
We describe a large scale computational model of electrical current flow in the cochlea which is constructed by a flexible Modified Nodal Analysis algorithm to incorporate electrical components representing hair cells and the intercellular radial and longitudinal current flow. The model is used as a laboratory to study the effects of changing longitudinal gap junctional coupling, and shows the way in which cochlear microphonic spreads and tuning is affected. The process for incorporating mechanical longitudinal coupling and feedback is described. We find a difference in tuning and attenuation depending on whether longitudinal or radial couplings are altered.
Tranebjærg, Lisbeth; Strenzke, Nicola; Lindholm, Sture; Rendtorff, Nanna D; Poulsen, Hanne; Khandelia, Himanshu; Kopec, Wojciech; Lyngbye, Troels J Brünnich; Hamel, Christian; Delettre, Cecile; Bocquet, Beatrice; Bille, Michael; Owen, Hanne H; Bek, Toke; Jensen, Hanne; Østergaard, Karen; Möller, Claes; Luxon, Linda; Carr, Lucinda; Wilson, Louise; Rajput, Kaukab; Sirimanna, Tony; Harrop-Griffiths, Katherine; Rahman, Shamima; Vona, Barbara; Doll, Julia; Haaf, Thomas; Bartsch, Oliver; Rosewich, Hendrik; Moser, Tobias; Bitner-Glindzicz, Maria
2018-02-01
Cerebellar ataxia, areflexia, pes cavus, optic atrophy and sensorineural hearing impairment (CAPOS) is a rare clinically distinct syndrome caused by a single dominant missense mutation, c.2452G>A, p.Glu818Lys, in ATP1A3, encoding the neuron-specific alpha subunit of the Na+/K+-ATPase α3. Allelic mutations cause the neurological diseases rapid dystonia Parkinsonism and alternating hemiplegia of childhood, disorders which do not encompass hearing or visual impairment. We present detailed clinical phenotypic information in 18 genetically confirmed patients from 11 families (10 previously unreported) from Denmark, Sweden, UK and Germany indicating a specific type of hearing impairment-auditory neuropathy (AN). All patients were clinically suspected of CAPOS and had hearing problems. In this retrospective analysis of audiological data, we show for the first time that cochlear outer hair cell activity was preserved as shown by the presence of otoacoustic emissions and cochlear microphonic potentials, but the auditory brainstem responses were grossly abnormal, likely reflecting neural dyssynchrony. Poor speech perception was observed, especially in noise, which was beyond the hearing level obtained in the pure tone audiograms in several of the patients presented here. Molecular modelling and in vitro electrophysiological studies of the specific CAPOS mutation were performed. Heterologous expression studies of α3 with the p.Glu818Lys mutation affects sodium binding to, and release from, the sodium-specific site in the pump, the third ion-binding site. Molecular dynamics simulations confirm that the structure of the C-terminal region is affected. In conclusion, we demonstrate for the first time evidence for auditory neuropathy in CAPOS syndrome, which may reflect impaired propagation of electrical impulses along the spiral ganglion neurons. This has implications for diagnosis and patient management. Auditory neuropathy is difficult to treat with conventional hearing aids, but preliminary improvement in speech perception in some patients suggests that cochlear implantation may be effective in CAPOS patients.
Cochlear implant microphone location affects speech recognition in diffuse noise.
Kolberg, Elizabeth R; Sheffield, Sterling W; Davis, Timothy J; Sunderhaus, Linsey W; Gifford, René H
2015-01-01
Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To date, however, the effect of microphone location on speech recognition in noise has focused primarily on hearing aid users. The purpose of this study was to (1) measure physical output for the T-Mic as compared with the integrated behind-the-ear (BTE) processor mic for various source azimuths, and (2) to investigate the effect of CI processor mic location for speech recognition in semi-diffuse noise with speech originating from various source azimuths as encountered in everyday communicative environments. A repeated-measures, within-participant design was used to compare performance across listening conditions. A total of 11 adults with Advanced Bionics CIs were recruited for this study. Physical acoustic output was measured on a Knowles Experimental Mannequin for Acoustic Research (KEMAR) for the T-Mic and BTE mic, with broadband noise presented at 0 and 90° (directed toward the implant processor). In addition to physical acoustic measurements, we also assessed recognition of sentences constructed by researchers at Texas Instruments, the Massachusetts Institute of Technology, and the Stanford Research Institute (TIMIT sentences) at 60 dBA for speech source azimuths of 0, 90, and 270°. Sentences were presented in a semi-diffuse restaurant noise originating from the R-SPACE 8-loudspeaker array. Signal-to-noise ratio was determined individually to achieve approximately 50% correct in the unilateral implanted listening condition with speech at 0°. Performance was compared across the T-Mic, 50/50, and the integrated BTE processor mic. The integrated BTE mic provided approximately 5 dB attenuation from 1500-4500 Hz for signals presented at 0° as compared with 90° (directed toward the processor). The T-Mic output was essentially equivalent for sources originating from 0 and 90°. Mic location also significantly affected sentence recognition as a function of source azimuth, with the T-Mic yielding the highest performance for speech originating from 0°. These results have clinical implications for (1) future implant processor design with respect to mic location, (2) mic settings for implant recipients, and (3) execution of advanced speech testing in the clinic. American Academy of Audiology.
Leuwer, R.; Müller, J.
2005-01-01
Aim of this report is to explain the current concept of hearing restoration using hearing aids. At present the main issues of conventional hearing aids are the relative benefits of analogue versus digital devices and different strategies for the improvement of hearing in noise. Implantable hearing aids provide a better sound quality and less distortion. The lack of directional microphones is the major disadvantage of the partially implantable hearing aids commercially available. Two different clinical studies about fully implantable hearing aids have been started in 2004. One of the most-promising developments seems to be the electric-acoustic stimulation. PMID:22073051
Towards a sub 15-dBA optical micromachined microphone
Kim, Donghwan; Hall, Neal A.
2014-01-01
Micromachined microphones with grating-based optical-interferometric readout have been demonstrated previously. These microphones are similar in construction to bottom-inlet capacitive microelectromechanical-system (MEMS) microphones, with the exception that optoelectronic emitters and detectors are placed inside the microphone's front or back cavity. A potential advantage of optical microphones in designing for low noise level is the use of highly-perforated microphone backplates to enable low-damping and low thermal-mechanical noise levels. This work presents an experimental study of a microphone diaphragm and backplate designed for optical readout and low thermal-mechanical noise. The backplate is 1 mm × 1 mm and is fabricated in a 2-μm-thick epitaxial silicon layer of a silicon-on-insulator wafer and contains a diffraction grating with 4-μm pitch etched at the center. The presented system has a measured thermal-mechanical noise level equal to 22.6 dBA. Through measurement of the electrostatic frequency response and measured noise spectra, a device model for the microphone system is verified. The model is in-turn used to identify design paths towards MEMS microphones with sub 15-dBA noise floors. PMID:24815250
ATP-gamma-S shifts the operating point of outer hair cell transduction towards scala tympani.
Bobbin, Richard P; Salt, Alec N
2005-07-01
ATP receptor agonists and antagonists alter cochlear mechanics as measured by changes in distortion product otoacoustic emissions (DPOAE). Some of the effects on DPOAEs are consistent with the hypothesis that ATP affects mechano-electrical transduction and the operating point of the outer hair cells (OHCs). This hypothesis was tested by monitoring the effect of ATP-gamma-S on the operating point of the OHCs. Guinea pigs anesthetized with urethane and with sectioned middle ear muscles were used. The cochlear microphonic (CM) was recorded differentially (scala vestibuli referenced to scala tympani) across the basal turn before and after perfusion (20 min) of the perilymph compartment with artificial perilymph (AP) and ATP-gamma-S dissolved in AP. The operating point was derived from the cochlear microphonics (CM) recorded in response low frequency (200 Hz) tones at high level (106, 112 and 118 dB SPL). The analysis procedure used a Boltzmann function to simulate the CM waveform and the Boltzmann parameters were adjusted to best-fit the calculated waveform to the CM. Compared to the initial perfusion with AP, ATP-gamma-S (333 microM) enhanced peak clipping of the positive peak of the CM (that occurs during organ of Corti displacements towards scala tympani), which was in keeping with ATP-induced displacement of the transducer towards scala tympani. CM waveform analysis quantified the degree of displacement and showed that the changes were consistent with the stimulus being centered on a different region of the transducer curve. The change of operating point meant that the stimulus was applied to a region of the transducer curve where there was greater saturation of the output on excursions towards scala tympani and less saturation towards scala vestibuli. A significant degree of recovery of the operating point was observed after washing with AP. Dose response curves generated by perfusing ATP-gamma-S (333 microM) in a cumulative manner yielded an EC(50) of 19.8 microM. The ATP antagonist PPADS (0.1 mM) failed to block the effect of ATP-gamma-S on operating point, suggesting the response was due to activation of metabotropic and not ionotropic ATP receptors. Multiple perfusions of AP had no significant effect (118 and 112 dB) or moved the operating point slightly (106 dB) in the direction opposite of ATP-gamma-S. Results are consistent with an ATP-gamma-S induced transducer change comparable to a static movement of the organ of Corti or reticular lamina towards scala tympani.
Ion flow in cochlear hair cells and the regulation of hearing sensitivity.
Patuzzi, Robert
2011-10-01
This paper discusses how ion transport proteins in the hair cells of the mammalian cochlea work to produce a sensitive but stable hearing organ. The transport proteins in the inner and outer hair cells are summarized (including their current voltage characteristics), and the roles of these proteins in determining intracellular Ca(2+), membrane potential, and ultimately cochlear sensitivity are discussed. The paper also discusses the role of the Ca(2+) sequestration sacs in outer hair cells in the autoregulation of hair cell membrane potential and cochlear gain, and how the underdamped control of Ca(2+) within these sacs may produce the observed slow oscillations in cochlear sensitivity and otoacoustic emissions after cochlear perturbations, including perilymphatic perfusions and prolonged low-frequency tones. The relative insensitivity of cochlear gain to short-term changes in the endocochlear potential is also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.
Cochlear Implant Microphone Location Affects Speech Recognition in Diffuse Noise
Kolberg, Elizabeth R.; Sheffield, Sterling W.; Davis, Timothy J.; Sunderhaus, Linsey W.; Gifford, René H.
2015-01-01
Background Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To date, however, the effect of microphone location on speech recognition in noise has focused primarily on hearing aid users. Purpose The purpose of this study was to (1) measure physical output for the T-Mic as compared with the integrated behind-the-ear(BTE) processor mic for various source azimuths, and (2) to investigate the effect of CI processor mic location for speech recognition in semi-diffuse noise with speech originating from various source azimuths as encountered in everyday communicative environments. Research Design A repeated-measures, within-participant design was used to compare performance across listening conditions. Study Sample A total of 11 adults with Advanced Bionics CIs were recruited for this study. Data Collection and Analysis Physical acoustic output was measured on a Knowles Experimental Mannequin for Acoustic Research (KEMAR) for the T-Mic and BTE mic, with broadband noise presented at 0 and 90° (directed toward the implant processor). In addition to physical acoustic measurements, we also assessed recognition of sentences constructed by researchers at Texas Instruments, the Massachusetts Institute of Technology, and the Stanford Research Institute (TIMIT sentences) at 60 dBA for speech source azimuths of 0, 90, and 270°. Sentences were presented in a semi-diffuse restaurant noise originating from the R-SPACE 8-loudspeaker array. Signal-to-noise ratio was determined individually to achieve approximately 50% correct in the unilateral implanted listening condition with speech at 0°. Performance was compared across the T-Mic, 50/50, and the integrated BTE processor mic. Results The integrated BTE mic provided approximately 5 dB attenuation from 1500–4500 Hz for signals presented at 0° as compared with 90° (directed toward the processor). The T-Mic output was essentially equivalent for sources originating from 0 and 90°. Mic location also significantly affected sentence recognition as a function of source azimuth, with the T-Mic yielding the highest performance for speech originating from 0°. Conclusions These results have clinical implications for (1) future implant processor design with respect to mic location, (2) mic settings for implant recipients, and (3) execution of advanced speech testing in the clinic. PMID:25597460
Stimulation of the cochlea using green laser light
NASA Astrophysics Data System (ADS)
Wenzel, G. I.; Balster, S.; Lim, H. H.; Zhang, K.; Reich, U.; Lubatschowski, H.; Ertmer, W.; Lenarz, T.; Reuter, G.
2009-02-01
The success of conventional hearing aids and electrical cochlear implants have generally been limited to hearing in quiet situations, in part due to a lack of localized (i.e., frequency specificity) sensorineural activation and subsequent impaired speech discrimination in noise. Laser light is a source of energy that can be focused in a controlled manner and may provide more localized activation of the inner ear, the cochlea. Compound action potentials have been elicited using 2.12 µm laser pulses through activation of auditory nerve fibers (Izzo et al. 2006). Laser stimulation (813 nm) of the cochlea has shown to induce basilar membrane motion and cochlear microphonic potentials (Fridberger et al. 2006). We sought to assess if visible light (green, 532 nm, 10 ns pulses) could be used to consistently activate the cochlea. The laser parameters were selected based on our initial attempt to induce an optoacoustic effect as the energy transfer mechanism to the cochlea. Click evoked auditory brainstem responses (AABRs) were recorded preoperatively in ketamine-anesthetized guinea pigs to confirm normal hearing. The bulla and then the cochlea were exposed. Optically evoked ABRs (OABR) were recorded in response to laser stimulation with a 50 µm optical fiber (532 nm, 10 ns pulses, 500 repetitions, 10 pulses/s; Nd:YAG laser) at the round window (RW) directed towards the basilar membrane (BM). OABRs similar in morphology to acoustically evoked ABRs, except for shorter latencies, were obtained for stimulation through the RW with energy levels between 1.7-30 µJ/pulse. The OABRs increased with increasing energy level reaching a saturation level around 13-15 µJ/pulse. Furthermore the responses remained consistent across stimulation over time, including stimulation at 13 µJ/pulse for over 30 minutes, indicating minimal or no damage within the cochlea with this type of laser stimulation. Overall we have demonstrated that laser light stimulation with 532 nm has potential for a new type of auditory prosthesis that can activate the cochlea without any apparent functional damage. Further studies are needed to determine the optimal laser parameters and fiber placement locations for localized and tonotopic activation.
Benefit of the UltraZoom beamforming technology in noise in cochlear implant users.
Mosnier, Isabelle; Mathias, Nathalie; Flament, Jonathan; Amar, Dorith; Liagre-Callies, Amelie; Borel, Stephanie; Ambert-Dahan, Emmanuèle; Sterkers, Olivier; Bernardeschi, Daniele
2017-09-01
The objectives of the study were to demonstrate the audiological and subjective benefits of the adaptive UltraZoom beamforming technology available in the Naída CI Q70 sound processor, in cochlear-implanted adults upgraded from a previous generation sound processor. Thirty-four adults aged between 21 and 89 years (mean 53 ± 19) were prospectively included. Nine subjects were unilaterally implanted, 11 bilaterally and 14 were bimodal users. The mean duration of cochlear implant use was 7 years (range 5-15 years). Subjects were tested in quiet with monosyllabic words and in noise with the adaptive French Matrix test in the best-aided conditions. The test setup contained a signal source in front of the subject and three noise sources at +/-90° and 180°. The noise was presented at a fixed level of 65 dB SPL and the level of speech signal was varied to obtain the speech reception threshold (SRT). During the upgrade visit, subjects were tested with the Harmony and with the Naída CI sound processors in omnidirectional microphone configuration. After a take-home phase of 2 months, tests were repeated with the Naída CI processor with and without UltraZoom. Subjective assessment of the sound quality in daily environments was recorded using the APHAB questionnaire. No difference in performance was observed in quiet between the two processors. The Matrix test in noise was possible in the 21 subjects with the better performance. No difference was observed between the two processors for performance in noise when using the omnidirectional microphone. At the follow-up session, the median SRT with the Naída CI processor with UltraZoom was -4 dB compared to -0.45 dB without UltraZoom. The use of UltraZoom improved the median SRT by 3.6 dB (p < 0.0001, Wilcoxon paired test). When looking at the APHAB outcome, improvement was observed for speech understanding in noisy environments (p < 0.01) and in aversive situations (p < 0.05) in the group of 21 subjects who were able to perform the Matrix test in noise and for speech understanding in noise (p < 0.05) in the group of 13 subjects with the poorest performance, who were not able to perform the Matrix test in noise. The use of UltraZoom beamforming technology, available on the new sound processor Naída CI, improves speech performance in difficult and realistic noisy conditions when the cochlear implant user needs to focus on the person speaking at the front. Using the APHAB questionnaire, a subjective benefit for listening in background noise was also observed in subjects with good performance as well as in those with poor performance. This study highlighted the importance of upgrading CI recipients to new technology and to include assessment in noise and subjective feedback evaluation as part of the process.
Bertlich, Mattis; Ihler, Friedrich; Weiss, Bernhard G; Freytag, Saskia; Jakob, Mark; Strupp, Michael; Pellkofer, Hannah; Canis, Martin
2017-09-01
The potential of Fingolimod (FTY-720), a sphingosine-1-phosphate analogue, to revoke the changes in cochlear blood flow induced by tumor necrosis factor (TNF) was investigated. Impairment of cochlear blood flow has often been considered as the common final pathway of various inner ear pathologies. TNF, an ubiquitous cytokine, plays a major role in these pathologies, reducing cochlear blood flow via sphingosine-1-phosphate-signaling. Fifteen Dunkin-Hartley guinea pigs were randomly assigned to one of three groups (placebo/placebo, TNF/placebo, TNF/FTY-720). Cochlear microcirculation was quantified over 60 minutes by in vivo fluorescence microscopy before and after topical application of placebo or TNF (5 ng/ml) and after subsequent application of placebo or FTY-720 (200 μg/ml). Treatment with TNF led to a significant decrease of cochlear blood flow.Following this, application of placebo caused no significant changes while application of FTY-720 caused a significant rise in cochlear blood flow. FTY-720 is capable of reversing changes in cochlear blood flow induced by application of TNF. This makes FTY-720 a valid candidate for potential treatment of numerous inner ear pathologies.
Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez
2016-01-01
The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Long latency auditory evoked potentials in children with cochlear implants: systematic review.
Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de
2013-11-25
The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.
Verbal Working Memory in Children With Cochlear Implants
Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.
2017-01-01
Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747
Preventing Ototoxic Synergy of Prior Noise Trauma During Aminoglycoside Therapy
2015-12-01
cochlear blood flow . Hearing Research 313, 38-46 (2014). 12. Koo, J.-W. et al. Endotoxemia-mediated inflammation potentiates cochlear uptake of...event in response to a need for higher cochlear blood flow . A 3.7% dilation was adequate for a 20% increase of blood flow 10. On the contrary...summation of the two insults. We have found that prior sound exposure enhances cochlear uptake of aminoglycosides, providing a mechanistic basis for the
Kurbel, Sven; Borzan, Vladimir; Golem, Hilda; Dinjar, Kristijan
2017-02-01
Reported cochlear potential values of near 150 mV are often attributed to endolymph itself, although membrane potentials result from ion fluxes across the adjacent semipermeable membranes due to concentration gradients. Since any two fluids separated by a semipermeable membrane develop potential due to differences in solute concentrations, a proposed interpretation here is that positive potential emanates from the Reissner membrane due to small influx of sodium from perilymph to endolymph. Basolateral hair cell membranes leak potassium into the interstitial fluid and this negative potential inside hair cells further augments the electric gradient of cochlear potential. Taken together as a sum, these two potentials are near the reported values of cochlear potential. This is based on reported data for cochlear fluids used for the calculation of Nernst and Goldman potentials. The reported positive potential of Reissner membrane can be explained almost entirely by the traffic of Na+ that enters endolymph through this membrane. At the apical membrane of hair cells, acoustic stimulation modulates stereocillia permeability to potassium. Potassium concentration gradients on the apical membrane are low (the calculated Nernst value is <+3 mV), suggesting that the potassium current is not caused by the local potassium concentration gradient, but an electric field between the positive sodium generated potential on the Reissner membrane and negative inside hair cells. Potassium is forced by this overall electric field to enter hair cells when stereocilia are permeable due to mechanical bending. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.
Physiopathology of the cochlear microcirculation.
Shi, Xiaorui
2011-12-01
Normal blood supply to the cochlea is critically important for establishing the endocochlear potential and sustaining production of endolymph. Abnormal cochlear microcirculation has long been considered an etiologic factor in noise-induced hearing loss, age-related hearing loss (presbycusis), sudden hearing loss or vestibular function, and Meniere's disease. Knowledge of the mechanisms underlying the pathophysiology of cochlear microcirculation is of fundamental clinical importance. A better understanding of cochlear blood flow (CoBF) will enable more effective management of hearing disorders resulting from aberrant blood flow. This review focuses on recent discoveries and findings related to the physiopathology of the cochlear microvasculature. Published by Elsevier B.V.
Physiopathology of the Cochlear Microcirculation
Shi, Xiaorui
2011-01-01
Normal blood supply to the cochlea is critically important for establishing the endocochlear potential and sustaining production of endolymph. Abnormal cochlear microcirculation has long been considered an etiologic factor in noise-induced hearing loss, age-related hearing loss (presbycusis), sudden hearing loss or vestibular function, and Meniere's disease. Knowledge of the mechanisms underlying the pathophysiology of cochlear microcirculation is of fundamental clinical importance. A better understanding of cochlear blood flow (CoBF) will enable more effective management of hearing disorders resulting from aberrant blood flow. This review focuses on recent discoveries and findings related to the physiopathology of the cochlear microvasculature. PMID:21875658
Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 CP810 Sound Processor.
Dillier, Norbert; Lai, Wai Kong
2015-06-11
The Nucleus(®) 5 System Sound Processor (CP810, Cochlear™, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom™ Sound Processor (Cochlear™) for speech in quiet and noise for a subset of the processing options. This study compares the two processing options suggested to be used in noisy environments, Zoom and Beam, for various sound field conditions using a standardized speech in noise matrix test (Oldenburg sentences test). Nine German-speaking subjects who previously had been using the Freedom speech processor and subsequently were upgraded to the CP810 device participated in this series of additional evaluation tests. The speech reception threshold (SRT for 50% speech intelligibility in noise) was determined using sentences presented via loudspeaker at 65 dB SPL in front of the listener and noise presented either via the same loudspeaker (S0N0) or at 90 degrees at either the ear with the sound processor (S0NCI+) or the opposite unaided ear (S0NCI-). The fourth noise condition consisted of three uncorrelated noise sources placed at 90, 180 and 270 degrees. The noise level was adjusted through an adaptive procedure to yield a signal to noise ratio where 50% of the words in the sentences were correctly understood. In spatially separated speech and noise conditions both Zoom and Beam could improve the SRT significantly. For single noise sources, either ipsilateral or contralateral to the cochlear implant sound processor, average improvements with Beam of 12.9 and 7.9 dB in SRT were found. The average SRT of -8 dB for Beam in the diffuse noise condition (uncorrelated noise from both sides and back) is truly remarkable and comparable to the performance of normal hearing listeners in the same test environment. The static directivity (Zoom) option in the diffuse noise condition still provides a significant benefit of 5.9 dB in comparison with the standard omnidirectional microphone setting. These results indicate that CI recipients may improve their speech recognition in noisy environments significantly using these directional microphone-processing options.
Harris, Jill; Kamke, Marc R
2014-11-01
Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
[Protective effect of indirect activator of calcium pump on noise-induced hearing loss].
Liu, Jun; Yu, Ning; Han, Dongyi; Yang, Weiyan; Li, Xingqi
2002-12-01
To investigate the possible protective effect of phorbol-12-myristate-13-acetate (PMA), an activator of protein kinase C (PKC) and indirect activator of Ca2+ pump, on noise-induced hearing loss (NIHL). Twenty guinea pigs were divided randomly into two groups, and then perfused with artificial perilymph solutions in one group and with artificial perilymph solutions containing 3 mumol/L PMA in the other one, respectively. All animals were exposed with 100 dB SPL white noise for 2 hours. Cochlear microphonics (CM) and compound action potential (CAP) were recorded from the round window (RW) before noise exposure and 2 hours after noise exposure. There was no significant difference in CAP threshold and CM amplitude between two groups before noise exposure. A significant difference was observed in CAP threshold and CM amplitude between two groups after noise exposure. The amplitude of CM decreased and the threshold of CAP increased in both group after noise exposure, but in the PMA group the decrease of the amplitude of CM was higher while the increase of threshold of CAP lower than that in control (P < 0.05). PMA might have partly protective effect on NIHL. These findings indirectly proved that intracellular Ca2+ overload might involve in the mechanism of NIHL.
Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ
Chikar, Jennifer A.; Batts, Shelley A.; Pfingst, Bryan E.; Raphael, Yehoash
2009-01-01
Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament – labeled nerve processes within the scala tympani, and the spatial relationship between them. PMID:19428528
Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.
Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash
2009-05-15
Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.
Bilateral cochlear implantation in the ferret: A novel animal model for behavioral studies
Hartley, Douglas E.H.; Vongpaisal, Tara; Xu, Jin; Shepherd, Robert K.; King, Andrew J.; Isaiah, Amal
2010-01-01
Bilateral cochlear implantation has recently been introduced with the aim of improving both speech perception in background noise and sound localization. Although evidence suggests that binaural perception is possible with two cochlear implants, results in humans are variable. To explore potential contributing factors to these variable outcomes, we have developed a behavioral animal model of bilateral cochlear implantation in a novel species, the ferret. Although ferrets are ideally suited to psychophysical and physiological assessments of binaural hearing, cochlear implantation has not been previously described in this species. This paper describes the techniques of deafening with aminoglycoside administration, surgical implantation of an intracochlear array and chronic intracochlear electrical stimulation with monitoring for electrode integrity and efficacy of stimulation. Experiments have been presented elsewhere to show that the model can be used to study behavioral and electrophysiological measures of binaural hearing in chronically implanted animals. This paper demonstrates that cochlear implantation and chronic intracochlear electrical stimulation are both safe and effective in ferrets, opening up the possibility of using this model to study potential protective effects of bilateral cochlear implantation on the developing central auditory pathway. Since ferrets can be used to assess psychophysical and physiological aspects of hearing along with the structure of the auditory pathway in the same animals, we anticipate that this model will help develop novel neuroprosthetic therapies for use in humans. PMID:20576507
Tabuchi, Keiji; Nishimura, Bungo; Tanaka, Shuho; Hayashi, Kentaro; Hirose, Yuki; Hara, Akira
2010-06-01
A large amount of energy produced by active aerobic metabolism is necessary for the cochlea to maintain its function. This makes the cochlea vulnerable to blockade of cochlear blood flow and interruption of the oxygen supply. Although certain forms of human idiopathic sudden sensorineural hearing loss reportedly arise from ischemic injury, the pathological mechanism of cochlear ischemia-reperfusion injury has not been fully elucidated. Recent animal studies have shed light on the mechanisms of cochlear ischemia-reperfusion injury. It will help in the understanding of the pathology of cochlear ischemia-reperfusion injury to classify this injury into ischemic injury and reperfusion injury. Excitotoxicity, mainly observed during the ischemic period, aggravates the injury of primary auditory neurons. On the other hand, oxidative damage induced by hydroxyl radicals and nitric oxide enhances cochlear reperfusion injury. This article briefly summarizes the generation mechanisms of cochlear ischemia-reperfusion injury and potential therapeutic targets that could be developed for the effective management of this injury type.
Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi
2018-05-18
OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.
Schvartz-Leyzac, Kara C; Pfingst, Bryan E
2016-11-01
Electrically evoked compound action potential (ECAP) measures of peak amplitude, and amplitude-growth function (AGF) slope have been shown to reflect characteristics of cochlear health (primarily spiral ganglion density) in anesthetized cochlear-implanted guinea pigs. Likewise, the effect of increasing the interphase gap (IPG) in each of these measures also reflects SGN density in the implanted guinea pig. Based on these findings, we hypothesize that suprathreshold ECAP measures, and also how they change as the IPG is increased, have the potential to be clinically applicable in human subjects. However, further work is first needed in order to determine the characteristics of these measures in humans who use cochlear implants. The current study examined across-site patterns of suprathreshold ECAP measures in 10 bilaterally-implanted, adult cochlear implant users. Results showed that both peak amplitude and slope of the AGF varied significantly from electrode to electrode in ear-specific patterns across the subjects' electrode arrays. As expected, increasing the IPG on average increased the peak amplitude and slope. Across ears, there was a significant, negative correlation between the slope of the ECAP AGF and the duration of hearing loss. Across-site patterns of ECAP peak amplitude and AGF slopes were also compared with common ground impedance values and significant correlations were observed in some cases, depending on the subject and condition. The results of this study, coupled with previous studies in animals, suggest that it is feasible to measure the change in suprathreshold ECAP measures as the IPG increases on most electrodes. Further work is needed to investigate the relationship between these measures and cochlear implant outcomes, and determine how these measures might be used when programming a cochlear-implant processor. Published by Elsevier B.V.
ERIC Educational Resources Information Center
Bakar, Zaharah Abu; Brown, P. Margaret; Remine, Maria D.
2010-01-01
This study investigated the potential effects of cochlear implantation and age at implantation on maternal interactional sensitivity. Three groups of dyads were studied at two points over 1 year. The hearing aid (HA) group wore hearing aids throughout the study, the early cochlear implanted (ECI) group were implanted prior to 22 months of age, and…
Modeling high signal-to-noise ratio in a novel silicon MEMS microphone with comb readout
NASA Astrophysics Data System (ADS)
Manz, Johannes; Dehe, Alfons; Schrag, Gabriele
2017-05-01
Strong competition within the consumer market urges the companies to constantly improve the quality of their devices. For silicon microphones excellent sound quality is the key feature in this respect which means that improving the signal-to-noise ratio (SNR), being strongly correlated with the sound quality is a major task to fulfill the growing demands of the market. MEMS microphones with conventional capacitive readout suffer from noise caused by viscous damping losses arising from perforations in the backplate [1]. Therefore, we conceived a novel microphone design based on capacitive read-out via comb structures, which is supposed to show a reduction in fluidic damping compared to conventional MEMS microphones. In order to evaluate the potential of the proposed design, we developed a fully energy-coupled, modular system-level model taking into account the mechanical motion, the slide film damping between the comb fingers, the acoustic impact of the package and the capacitive read-out. All submodels are physically based scaling with all relevant design parameters. We carried out noise analyses and due to the modular and physics-based character of the model, were able to discriminate the noise contributions of different parts of the microphone. This enables us to identify design variants of this concept which exhibit a SNR of up to 73 dB (A). This is superior to conventional and at least comparable to high-performance variants of the current state-of-the art MEMS microphones [2].
Novel Methods for Sensing Acoustical Emissions From the Knee for Wearable Joint Health Assessment.
Teague, Caitlin N; Hersek, Sinan; Toreyin, Hakan; Millard-Stafford, Mindy L; Jones, Michael L; Kogler, Geza F; Sawka, Michael N; Inan, Omer T
2016-08-01
We present the framework for wearable joint rehabilitation assessment following musculoskeletal injury. We propose a multimodal sensing (i.e., contact based and airborne measurement of joint acoustic emission) system for at-home monitoring. We used three types of microphones-electret, MEMS, and piezoelectric film microphones-to obtain joint sounds in healthy collegiate athletes during unloaded flexion/extension, and we evaluated the robustness of each microphone's measurements via: 1) signal quality and 2) within-day consistency. First, air microphones acquired higher quality signals than contact microphones (signal-to-noise-and-interference ratio of 11.7 and 12.4 dB for electret and MEMS, respectively, versus 8.4 dB for piezoelectric). Furthermore, air microphones measured similar acoustic signatures on the skin and 5 cm off the skin (∼4.5× smaller amplitude). Second, the main acoustic event during repetitive motions occurred at consistent joint angles (intra-class correlation coefficient ICC(1, 1) = 0.94 and ICC(1, k) = 0.99). Additionally, we found that this angular location was similar between right and left legs, with asymmetry observed in only a few individuals. We recommend using air microphones for wearable joint sound sensing; for practical implementation of contact microphones in a wearable device, interface noise must be reduced. Importantly, we show that airborne signals can be measured consistently and that healthy left and right knees often produce a similar pattern in acoustic emissions. These proposed methods have the potential for enabling knee joint acoustics measurement outside the clinic/lab and permitting long-term monitoring of knee health for patients rehabilitating an acute knee joint injury.
Improving the accuracy of smart devices to measure noise exposure.
Roberts, Benjamin; Kardous, Chucri; Neitzel, Richard
2016-11-01
Occupational noise exposure is one of the most frequent hazards present in the workplace; up to 22 million workers have potentially hazardous noise exposures in the U.S. As a result, noise-induced hearing loss is one of the most common occupational injuries in the U.S. Workers in manufacturing, construction, and the military are at the highest risk for hearing loss. Despite the large number of people exposed to high levels of noise at work, many occupations have not been adequately evaluated for noise exposure. The objective of this experiment was to investigate whether or not iOS smartphones and other smart devices (Apple iPhones and iPods) could be used as reliable instruments to measure noise exposures. For this experiment three different types of microphones were tested with a single model of iPod and three generations of iPhones: the internal microphones on the device, a low-end lapel microphone, and a high-end lapel microphone marketed as being compliant with the International Electrotechnical Commission's (IEC) standard for a Class 2-microphone. All possible combinations of microphones and noise measurement applications were tested in a controlled environment using several different levels of pink noise ranging from 60-100 dBA. Results were compared to simultaneous measurements made using a Type 1 sound level measurement system. Analysis of variance and Tukey's honest significant difference (HSD) test were used to determine if the results differed by microphone or noise measurement application. Levels measured with external microphones combined with certain noise measurement applications did not differ significantly from levels measured with the Type 1 sound measurement system. Results showed that it may be possible to use iOS smartphones and smart devices, with specific combinations of measurement applications and calibrated external microphones, to collect reliable, occupational noise exposure data under certain conditions and within the limitations of the device. Further research is needed to determine how these devices compare to traditional noise dosimeter under real-world conditions.
NASA Astrophysics Data System (ADS)
Abiy, Lidet; Telischi, Fred; Parel, Jean-Marie A.; Manns, Fabrice; Saettele, Ralph; Morawski, Krzysztof; Ozdamar, Ozcan; Borgos, John; Delgado, Rafael; Miskiel, Edward; Yavuz, Erdem
2003-06-01
The aim of this project is the development of a microsurgical laser Doppler (LD) probe that simultaneously monitors blood flow and Electrocochleography (ECochG) from the round window of the ear. The device will prevent neurosensory hearing loss during acoustic neuroma surgery by preventing damage to the internal auditory nerve and to the cochlear blood flow supply. A commercially available 0.5 mm diameter Laser-Doppler velocimetry probe (LaserFlo, Vasamedics) was modified to integrate an ECochG electrode. A tube for suction and irrigation was incorporated into a sheath of the probe shaft, to facilitate cleaning of the round window (RW) and allow drug delivery to the round window membrane. The prototype microprobe was calibrated on a single vessel model and tested in vivo in a rabbit model. Preliminary results indicate that the microprobe was able to measure changes in cochlear blood flow (CBF) and ECochG potentials from the round window of rabbits in vivo. The microprobe is suitable for monitoring cochlear blood flow and auditory cochlear potentials during human surgery.
Music mixing preferences of cochlear implant recipients: a pilot study.
Buyens, Wim; van Dijk, Bas; Moonen, Marc; Wouters, Jan
2014-05-01
Music perception and appraisal are generally poor in cochlear implant recipients. Simple musical structures, lyrics that are easy to follow, and clear rhythm/beat have been reported among the top factors to enhance music enjoyment. The present study investigated the preference for modified relative instrument levels in music with normal-hearing and cochlear implant subjects. In experiment 1, test subjects were given a mixing console and multi-track recordings to determine their most enjoyable audio mix. In experiment 2, a preference rating experiment based on the preferred relative level settings in experiment 1 was performed. Experiment 1 was performed with four postlingually deafened cochlear implant subjects, experiment 2 with ten normal-hearing and ten cochlear implant subjects. A significant difference in preference rating was found between normal-hearing and cochlear implant subjects. The latter preferred an audio mix with larger vocals-to-instruments ratio. In addition, given an audio mix with clear vocals and attenuated instruments, cochlear implant subjects preferred the bass/drum track to be louder than the other instrument tracks. The original audio mix in real-world music might not be suitable for cochlear implant recipients. Modifying the relative instrument level settings potentially improves music enjoyment.
Bertlich, Mattis; Ihler, Friedrich; Freytag, Saskia; Weiss, Bernhard G; Strupp, Michael; Canis, Martin
2015-01-01
Betahistine is a histamine-like drug that is considered beneficial in Ménière's disease by increasing cochlear blood flow. Acting as an agonist at the histamine H1-receptor and as an inverse agonist at the H3-receptor, these receptors as well as the adrenergic α2-receptor were investigated for betahistine effects on cochlear blood flow. A total of 54 Dunkin-Hartley guinea pigs were randomly assigned to one of nine groups treated with a selection of H1-, H3- or α2-selective agonists and antagonists together with betahistine. Cochlear blood flow and mean arterial pressure were recorded for 3 min before and 15 min after infusion. Blockage of the H3- or α2-receptors caused a suppression of betahistine-mediated typical changes in cochlear blood flow or blood pressure. Activation of H3-receptors caused a drop in cochlear blood flow and blood pressure. H1-receptors showed no involvement in betahistine-mediated changes of cochlear blood flow. Betahistine most likely affects cochlear blood flow through histaminergic H3-heteroreceptors. © 2015 S. Karger AG, Basel.
Stanford Center for Military Photomedicine
2014-09-08
cochlear implants after blast injury. A.2. WOUND HEALING. We have used several in vivo and in vitro models of wound healing to study the basic cell and...clinical information we will obtain has the potential to fundamentally alter the diagnosis and treatment of human cochlear pathology. Our microscope...of live guinea pigs, and have shown that FME can resolve cochlear structures in live subjects in a manner far superior to that of any other existing
Evaluation of Jet Fuel and Noise-Induced Hearing Loss in Rats (Rattus norvegicus)
2014-05-13
product otoacoustic emissions (DPOAE) and compound action potential (CAP) testing of the cochlear nerve. Inner ear hair cell loss was also not affected...conclusion by revealing that exposure to JP-8 combined with noise may result in the loss of pre-neural cochlear sensitivity as shown by suppression of...distortion product otoacoustic emissions (DPOAE) and depletion of cochlear sensory cells as evidenced by cytocochleograms that plot the percentage of
Ricketts, Todd A; Picou, Erin M
2013-09-01
This study aimed to evaluate the potential utility of asymmetrical and symmetrical directional hearing aid fittings for school-age children in simulated classroom environments. This study also aimed to evaluate speech recognition performance of children with normal hearing in the same listening environments. Two groups of school-age children 11 to 17 years of age participated in this study. Twenty participants had normal hearing, and 29 participants had sensorineural hearing loss. Participants with hearing loss were fitted with behind-the-ear hearing aids with clinically appropriate venting and were tested in 3 hearing aid configurations: bilateral omnidirectional, bilateral directional, and asymmetrical directional microphones. Speech recognition testing was completed in each microphone configuration in 3 environments: Talker-Front, Talker-Back, and Question-Answer situations. During testing, the location of the speech signal changed, but participants were always seated in a noisy, moderately reverberant classroom-like room. For all conditions, results revealed expected effects of directional microphones on speech recognition performance. When the signal of interest was in front of the listener, bilateral directional microphone was best, and when the signal of interest was behind the listener, bilateral omnidirectional microphone was best. Performance with asymmetric directional microphones was between the 2 symmetrical conditions. The magnitudes of directional benefits and decrements were not significantly correlated. In comparison with their peers with normal hearing, children with hearing loss performed similarly to their peers with normal hearing when fitted with directional microphones and the speech was from the front. In contrast, children with normal hearing still outperformed children with hearing loss if the speech originated from behind, even when the children were fitted with the optimal hearing aid microphone mode for the situation. Bilateral directional microphones can be effective in improving speech recognition performance for children in the classroom, as long as child is facing the talker of interest. Bilateral directional microphones, however, can impair performance if the signal originates from behind a listener. However, these data suggest that the magnitude of decrement is not predictable from an individual's benefit. The results re-emphasize the importance of appropriate switching between microphone modes so children can take full advantage of directional benefits without being hurt by directional decrements. An asymmetric fitting limits decrements, but does not lead to maximum speech recognition scores when compared with the optimal symmetrical fitting. Therefore, the asymmetric mode may not be the best option as a default fitting for children in a classroom environment. While directional microphones improve performance for children with hearing loss, their performance in most conditions continues to be impaired relative to their normal-hearing peers, particularly when the signals of interest originate from behind or from an unpredictable location.
Ye, Rui; Liu, Jun; Jia, Zhiying; Wang, Hongyang; Wang, YongAn; Sun, Wei; Wu, Xuan; Zhao, Zhifei; Niu, Baolong; Li, Xingqi; Dai, Guanghai; Li, Jianxiong
2016-06-13
BACKGROUND There is increasing evidence that adenosine triphosphate (ATP), a well-known neurotransmitter and neuromodulator in the central nervous system, plays an important role as an extracellular chemical messenger in the cochlea. MATERIAL AND METHODS Using a whole-cell recording technique, we studied the effects of ATP on isolated Hensen's cells, which are supporting cells in the cochlea, to determine if they are involved in the transduction of ions with hair cells. RESULTS ATP (0.1-10 µM) reduced the potassium current (IK+) in the majority of the recorded Hensen's cells (21 out of 25 cells). An inward current was also induced by high concentrations of ATP (100 µM to 10 mM), which was reversibly blocked by 100 µM suramin (a purinergic antagonist) and blocked by nifedipine (an L-type calcium channel blocker). After the cochleas were perfused with artificial perilymph solutions containing nifedipine and exposed to noise, the amplitude increase in the compound action potential (CAP) threshold and the reduction in cochlear microphonics was lower than when they were exposed to noise alone. CONCLUSIONS Our results suggest that ATP can block IK+ channels at a low concentration and induce an inward Ca2+ current at high concentrations, which is reversed by purinergic receptors. Nifedipine may have a partially protective effect on noise-induced hearing loss (NIHL).
Ethical considerations in resource allocation in a cochlear implant program.
Westerberg, Brian D; Pijl, Sipke; McDonald, Michael
2008-04-01
To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.
Remote programming of cochlear implants: a telecommunications model.
McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S
2010-09-01
Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.
Using Evoked Potentials to Match Interaural Electrode Pairs with Bilateral Cochlear Implants
Delgutte, Bertrand
2007-01-01
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency–channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable. PMID:17225976
Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants.
Smith, Zachary M; Delgutte, Bertrand
2007-03-01
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency-channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable.
Ross, Astin M.; Rahmani, Sahar; Prieskorn, Diane M.; Dishman, Acacia F; Miller, Josef M.; Lahann, Joerg; Altschuler, Richard A.
2016-01-01
Delivery of pharmaceuticals to the cochleae of patients with auditory dysfunction could potentially have many benefits from enhancing auditory nerve survival to protecting remaining sensory cells and their neuronal connections. Treatment would require platforms to enable drug delivery directly to the cochlea and increase the potential efficacy of intervention. Cochlear implant recipients are a specific patient subset that could benefit from local drug delivery as more candidates have residual hearing; and since residual hearing directly contributes to post-implantation hearing outcomes, it requires protection from implant insertion-induced trauma. This study assessed the feasibility of utilizing microparticles for drug delivery into cochlear fluids, testing persistence, distribution, biocompatibility, and drug release characteristics. To allow for delivery of multiple therapeutics, particles were composed of two distinct compartments; one containing polylactide-co-glycolide (PLGA), and one composed of acetal-modified dextran and PLGA. Following in vivo infusion, image analysis revealed microparticle persistence in the cochlea for at least 7 days post-infusion, primarily in the first and second turns. The majority of subjects maintained or had only slight elevation in auditory brainstem response thresholds at 7 days post-infusion compared to pre-infusion baselines. There was only minor to limited loss of cochlear hair cells and negligible immune response based on CD45+ immunolabling. When Piribedil-loaded microparticles were infused, Piribedil was detectable within the cochlear fluids at 7 days post-infusion. These results indicate that segmented microparticles are relatively inert, can persist, release their contents, and be functionally and biologically compatible with cochlear function and therefore are promising vehicles for cochlear drug delivery. PMID:26841263
Healy, Eric W; Yoho, Sarah E
2016-08-01
A primary complaint of hearing-impaired individuals involves poor speech understanding when background noise is present. Hearing aids and cochlear implants often allow good speech understanding in quiet backgrounds. But hearing-impaired individuals are highly noise intolerant, and existing devices are not very effective at combating background noise. As a result, speech understanding in noise is often quite poor. In accord with the significance of the problem, considerable effort has been expended toward understanding and remedying this issue. Fortunately, our understanding of the underlying issues is reasonably good. In sharp contrast, effective solutions have remained elusive. One solution that seems promising involves a single-microphone machine-learning algorithm to extract speech from background noise. Data from our group indicate that the algorithm is capable of producing vast increases in speech understanding by hearing-impaired individuals. This paper will first provide an overview of the speech-in-noise problem and outline why hearing-impaired individuals are so noise intolerant. An overview of our approach to solving this problem will follow.
Intrinsic regenerative potential of murine cochlear supporting cells.
Sinkkonen, Saku T; Chai, Renjie; Jan, Taha A; Hartman, Byron H; Laske, Roman D; Gahlen, Felix; Sinkkonen, Wera; Cheng, Alan G; Oshima, Kazuo; Heller, Stefan
2011-01-01
The lack of cochlear regenerative potential is the main cause for the permanence of hearing loss. Albeit quiescent in vivo, dissociated non-sensory cells from the neonatal cochlea proliferate and show ability to generate hair cell-like cells in vitro. Only a few non-sensory cell-derived colonies, however, give rise to hair cell-like cells, suggesting that sensory progenitor cells are a subpopulation of proliferating non-sensory cells. Here we purify from the neonatal mouse cochlea four different non-sensory cell populations by fluorescence-activated cell sorting (FACS). All four populations displayed proliferative potential, but only lesser epithelial ridge and supporting cells robustly gave rise to hair cell marker-positive cells. These results suggest that cochlear supporting cells and cells of the lesser epithelial ridge show robust potential to de-differentiate into prosensory cells that proliferate and undergo differentiation in similar fashion to native prosensory cells of the developing inner ear.
Real-time spectrum estimation–based dual-channel speech-enhancement algorithm for cochlear implant
2012-01-01
Background Improvement of the cochlear implant (CI) front-end signal acquisition is needed to increase speech recognition in noisy environments. To suppress the directional noise, we introduce a speech-enhancement algorithm based on microphone array beamforming and spectral estimation. The experimental results indicate that this method is robust to directional mobile noise and strongly enhances the desired speech, thereby improving the performance of CI devices in a noisy environment. Methods The spectrum estimation and the array beamforming methods were combined to suppress the ambient noise. The directivity coefficient was estimated in the noise-only intervals, and was updated to fit for the mobile noise. Results The proposed algorithm was realized in the CI speech strategy. For actual parameters, we use Maxflat filter to obtain fractional sampling points and cepstrum method to differentiate the desired speech frame and the noise frame. The broadband adjustment coefficients were added to compensate the energy loss in the low frequency band. Discussions The approximation of the directivity coefficient is tested and the errors are discussed. We also analyze the algorithm constraint for noise estimation and distortion in CI processing. The performance of the proposed algorithm is analyzed and further be compared with other prevalent methods. Conclusions The hardware platform was constructed for the experiments. The speech-enhancement results showed that our algorithm can suppresses the non-stationary noise with high SNR. Excellent performance of the proposed algorithm was obtained in the speech enhancement experiments and mobile testing. And signal distortion results indicate that this algorithm is robust with high SNR improvement and low speech distortion. PMID:23006896
Martins, Kelly Vasconcelos Chaves; Gil, Daniela
2017-01-01
Introduction The registry of the component P1 of the cortical auditory evoked potential has been widely used to analyze the behavior of auditory pathways in response to cochlear implant stimulation. Objective To determine the influence of aural rehabilitation in the parameters of latency and amplitude of the P1 cortical auditory evoked potential component elicited by simple auditory stimuli (tone burst) and complex stimuli (speech) in children with cochlear implants. Method The study included six individuals of both genders aged 5 to 10 years old who have been cochlear implant users for at least 12 months, and who attended auditory rehabilitation with an aural rehabilitation therapy approach. Participants were submitted to research of the cortical auditory evoked potential at the beginning of the study and after 3 months of aural rehabilitation. To elicit the responses, simple stimuli (tone burst) and complex stimuli (speech) were used and presented in free field at 70 dB HL. The results were statistically analyzed, and both evaluations were compared. Results There was no significant difference between the type of eliciting stimulus of the cortical auditory evoked potential for the latency and the amplitude of P1. There was a statistically significant difference in the P1 latency between the evaluations for both stimuli, with reduction of the latency in the second evaluation after 3 months of auditory rehabilitation. There was no statistically significant difference regarding the amplitude of P1 under the two types of stimuli or in the two evaluations. Conclusion A decrease in latency of the P1 component elicited by both simple and complex stimuli was observed within a three-month interval in children with cochlear implant undergoing aural rehabilitation. PMID:29018498
Simultaneous Communication Supports Learning in Noise by Cochlear Implant Users
Blom, Helen C.; Marschark, Marc; Machmer, Elizabeth
2017-01-01
Objectives This study sought to evaluate the potential of using spoken language and signing together (simultaneous communication, SimCom, sign-supported speech) as a means of improving speech recognition, comprehension, and learning by cochlear implant users in noisy contexts. Methods Forty eight college students who were active cochlear implant users, watched videos of three short presentations, the text versions of which were standardized at the 8th grade reading level. One passage was presented in spoken language only, one was presented in spoken language with multi-talker babble background noise, and one was presented via simultaneous communication with the same background noise. Following each passage, participants responded to 10 (standardized) open-ended questions designed to assess comprehension. Indicators of participants’ spoken language and sign language skills were obtained via self-reports and objective assessments. Results When spoken materials were accompanied by signs, scores were significantly higher than when materials were spoken in noise without signs. Participants’ receptive spoken language skills significantly predicted scores in all three conditions; neither their receptive sign skills nor age of implantation predicted performance. Discussion Students who are cochlear implant users typically rely solely on spoken language in the classroom. The present results, however, suggest that there are potential benefits of simultaneous communication for such learners in noisy settings. For those cochlear implant users who know sign language, the redundancy of speech and signs potentially can offset the reduced fidelity of spoken language in noise. Conclusion Accompanying spoken language with signs can benefit learners who are cochlear implant users in noisy situations such as classroom settings. Factors associated with such benefits, such as receptive skills in signed and spoken modalities, classroom acoustics, and material difficulty need to be empirically examined. PMID:28010675
Acute hyperfibrinogenemia impairs cochlear blood flow and hearing function in guinea pigs in vivo.
Ihler, Fritz; Strieth, Sebastian; Pieri, Nicos; Göhring, Peter; Canis, Martin
2012-03-01
Impairment of microcirculation is a possible cause of sudden sensorineural hearing loss (SSNHL). Fibrinogen is known as a risk factor for both microvascular dysfunction and SSNHL. Therefore, the aim of this study was to investigate the effect of elevated serum levels of fibrinogen on cochlear blood flow and hearing function in vivo. One group of guinea pigs received two consecutive injections of 100 mg fibrinogen while a control group received equimolar doses of albumin. Measurements of cochlear microcirculation by intravital microscopy and of hearing thresholds by auditory brainstem response (ABR) recordings were carried out before, after first and after second injection. Ten healthy guinea pigs were randomly assigned to a treatment group or a control group of five animals each. Serum fibrinogen levels were elevated after the first and second injections of fibrinogen compared to basal values and control group respectively. Increasing levels of fibrinogen were paralleled by decreasing cochlear blood flow as well as increasing hearing thresholds. Hearing threshold correlated negatively with cochlear blood flow. The effect of microcirculatory impairment on hearing function could be explained by a malfunction of the cochlear amplifier. Further investigation is needed to quantify cochlear potentials under elevated serum fibrinogen levels.
Optimization of programming parameters in children with the advanced bionics cochlear implant.
Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L
2012-05-01
Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal-to-noise ratio). Outcomes were analyzed using a paired t-test and a mixed-model repeated measures analysis of variance (ANOVA). T-levels set 10 CUs below "soft" resulted in significantly lower detection thresholds for all six Ling sounds and FM tones at 250, 1000, 3000, 4000, and 6000 Hz. When comparing programs differing by IDR and sensitivity, a 50 dB IDR with a 0 sensitivity setting showed significantly poorer thresholds for low frequency FM tones and voiced Ling sounds. Analysis of group mean scores for CNC words in quiet or HINT-C sentences in noise indicated no significant differences across IDR/sensitivity settings. Individual data, however, showed significant differences between IDR/sensitivity programs in noise; the optimal program differed across participants. In pediatric recipients of the Advanced Bionics cochlear implant device, manually setting T-levels with ascending loudness judgments should be considered when possible or when low-level sounds are inaudible. Study findings confirm the need to determine program settings on an individual basis as well as the importance of speech recognition verification measures in both quiet and noise. Clinical guidelines are suggested for selection of programming parameters in both young and older children. American Academy of Audiology.
Lai, Ying-Hui; Tsao, Yu; Lu, Xugang; Chen, Fei; Su, Yu-Ting; Chen, Kuang-Chao; Chen, Yu-Hsuan; Chen, Li-Ching; Po-Hung Li, Lieber; Lee, Chin-Hui
2018-01-20
We investigate the clinical effectiveness of a novel deep learning-based noise reduction (NR) approach under noisy conditions with challenging noise types at low signal to noise ratio (SNR) levels for Mandarin-speaking cochlear implant (CI) recipients. The deep learning-based NR approach used in this study consists of two modules: noise classifier (NC) and deep denoising autoencoder (DDAE), thus termed (NC + DDAE). In a series of comprehensive experiments, we conduct qualitative and quantitative analyses on the NC module and the overall NC + DDAE approach. Moreover, we evaluate the speech recognition performance of the NC + DDAE NR and classical single-microphone NR approaches for Mandarin-speaking CI recipients under different noisy conditions. The testing set contains Mandarin sentences corrupted by two types of maskers, two-talker babble noise, and a construction jackhammer noise, at 0 and 5 dB SNR levels. Two conventional NR techniques and the proposed deep learning-based approach are used to process the noisy utterances. We qualitatively compare the NR approaches by the amplitude envelope and spectrogram plots of the processed utterances. Quantitative objective measures include (1) normalized covariance measure to test the intelligibility of the utterances processed by each of the NR approaches; and (2) speech recognition tests conducted by nine Mandarin-speaking CI recipients. These nine CI recipients use their own clinical speech processors during testing. The experimental results of objective evaluation and listening test indicate that under challenging listening conditions, the proposed NC + DDAE NR approach yields higher intelligibility scores than the two compared classical NR techniques, under both matched and mismatched training-testing conditions. When compared to the two well-known conventional NR techniques under challenging listening condition, the proposed NC + DDAE NR approach has superior noise suppression capabilities and gives less distortion for the key speech envelope information, thus, improving speech recognition more effectively for Mandarin CI recipients. The results suggest that the proposed deep learning-based NR approach can potentially be integrated into existing CI signal processors to overcome the degradation of speech perception caused by noise.
Sharma, Anu; Campbell, Julia; Cardon, Garrett
2015-02-01
Cortical development is dependent on extrinsic stimulation. As such, sensory deprivation, as in congenital deafness, can dramatically alter functional connectivity and growth in the auditory system. Cochlear implants ameliorate deprivation-induced delays in maturation by directly stimulating the central nervous system, and thereby restoring auditory input. The scenario in which hearing is lost due to deafness and then reestablished via a cochlear implant provides a window into the development of the central auditory system. Converging evidence from electrophysiologic and brain imaging studies of deaf animals and children fitted with cochlear implants has allowed us to elucidate the details of the time course for auditory cortical maturation under conditions of deprivation. Here, we review how the P1 cortical auditory evoked potential (CAEP) provides useful insight into sensitive period cut-offs for development of the primary auditory cortex in deaf children fitted with cochlear implants. Additionally, we present new data on similar sensitive period dynamics in higher-order auditory cortices, as measured by the N1 CAEP in cochlear implant recipients. Furthermore, cortical re-organization, secondary to sensory deprivation, may take the form of compensatory cross-modal plasticity. We provide new case-study evidence that cross-modal re-organization, in which intact sensory modalities (i.e., vision and somatosensation) recruit cortical regions associated with deficient sensory modalities (i.e., auditory) in cochlear implanted children may influence their behavioral outcomes with the implant. Improvements in our understanding of developmental neuroplasticity in the auditory system should lead to harnessing central auditory plasticity for superior clinical technique. Copyright © 2014 Elsevier B.V. All rights reserved.
Microphones and Educational Media.
ERIC Educational Resources Information Center
Page, Marilyn
This paper describes the types of microphones that are available for use in media production. Definitions of 16 words and phrases used to describe microphones are followed by detailed descriptions of the two kinds of microphones as classified by mode of operation, i.e., velocity, or ribbon microphones, and pressure operated microphones, which…
Chang, Hao; Telang, Ravindra S; Sreebhavan, Sreevalsan; Tingle, Malcolm; Thorne, Peter R; Vlajkovic, Srdjan M
2017-01-01
Noise-induced hearing loss (NIHL) is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A 1 adenosine receptor agonist adenosine amine congener (ADAC) has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous) administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise.
Sreebhavan, Sreevalsan; Thorne, Peter R.
2017-01-01
Noise-induced hearing loss (NIHL) is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A1 adenosine receptor agonist adenosine amine congener (ADAC) has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous) administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise. PMID:28194422
Ototoxicity of salicylate, nonsteroidal antiinflammatory drugs, and quinine.
Jung, T T; Rhee, C K; Lee, C S; Park, Y S; Choi, D C
1993-10-01
Salicylates and most NSAIDS in high doses cause mild to moderate temporary hearing loss, either flat or greater in the high frequencies. Hearing loss is accompanied by tinnitus and suprathreshold changes. Salicylates may or may not exacerbate hearing loss and cochlear damage induced by noise. The mechanism of salicylate ototoxicity seems to be multifactorial. Morphologic studies suggest that no permanent cochlear damage occurs with salicylate ototoxicity. Electrophysiologic, morphologic, and in vitro data conclusively demonstrate that salicylate affects outer hair cells. In addition, salicylates appear to decrease cochlear blood flow. Salicylates and NSAIDs inhibit PG-forming cyclooxygenase, and recent studies suggest that abnormal levels of arachidonic acid metabolites consisting of decreased PGs and increased LTs may mediate salicylate ototoxicity. As with salicylate, quinine ototoxicity appears to be multifactorial in origin. The mechanism includes vasoconstriction and decreases in cochlear blood flow, as measured by laser Doppler flowmetry, motion photographic studies, and histologic studies. Reversible alterations of outer hair cells also appear to play an important role, as demonstrated by histology, electron microscopy, isolated hair cell studies, and cochlear potential evaluations. Unlike with salicylate, however, the role of prostaglandins in quinine ototoxicity has not been clearly demonstrated. Also, one of quinine's principal actions, antagonism of calcium-dependent potassium channels, has yet to be investigated for its potential role in ototoxicity.
NASA Astrophysics Data System (ADS)
Kuenzig, Thomas; Dehé, Alfons; Krumbein, Ulrich; Schrag, Gabriele
2018-05-01
Maxing out the technological limits in order to satisfy the customers’ demands and obtain the best performance of micro-devices and-systems is a challenge of today’s manufacturers. Dedicated system simulation is key to investigate the potential of device and system concepts in order to identify the best design w.r.t. the given requirements. We present a tailored, physics-based system-level modeling approach combining lumped with distributed models that provides detailed insight into the device and system operation at low computational expense. The resulting transparent, scalable (i.e. reusable) and modularly composed models explicitly contain the physical dependency on all relevant parameters, thus being well suited for dedicated investigation and optimization of MEMS devices and systems. This is demonstrated for an industrial capacitive silicon microphone. The performance of such microphones is determined by distributed effects like viscous damping and inhomogeneous capacitance variation across the membrane as well as by system-level phenomena like package-induced acoustic effects and the impact of the electronic circuitry for biasing and read-out. The here presented model covers all relevant figures of merit and, thus, enables to evaluate the optimization potential of silicon microphones towards high fidelity applications. This work was carried out at the Technical University of Munich, Chair for Physics of Electrotechnology. Thomas Kuenzig is now with Infineon Technologies AG, Neubiberg.
Simultaneous Communication and Cochlear Implants in the Classroom?
ERIC Educational Resources Information Center
Blom, Helen C.; Marschark, Marc
2015-01-01
This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users indicated that the student participants learned…
Relational Learning in Children with Deafness and Cochlear Implants
ERIC Educational Resources Information Center
Almeida-Verdu, Ana Claudia; Huziwara, Edson M.; de Souza, Deisy G.; de Rose, Julio C.; Bevilacqua, Maria Cecilia; Lopes, Jair, Jr.; Alves, Cristiane O.; McIlvane, William J.
2008-01-01
This four-experiment series sought to evaluate the potential of children with neurosensory deafness and cochlear implants to exhibit auditory-visual and visual-visual stimulus equivalence relations within a matching-to-sample format. Twelve children who became deaf prior to acquiring language (prelingual) and four who became deaf afterwards…
2010-08-01
are credited. Funding: Fleet Industrial Supply Center (FISC). Grant# N00244-08-1-0025. The funding flows from the Chief of Naval Operations...34, 35, 36 and 37). Middle Ear Function McCormick [22] studied hearing in the bottlenose dolphin (Tursiops truncatus) by measuring cochlear potentials...tympanic ligament attenuated the cochlear potentials by 18 dB with respect to the level obtained during preliminary tests, whereas removing the
Francis, Howard W; Pulsifer, Margaret B; Chinnici, Jill; Nutt, Robert; Venick, Holly S; Yeagle, Jennifer D; Niparko, John K
2004-05-01
This study explored factors associated with speech recognition outcomes in postmeningitic deafness (PMD). The results of cochlear implantation may vary in children with PMD because of sequelae that extend beyond the auditory periphery. To determine which factors might be most determinative of outcome of cochlear implantation in children with PMD. Retrospective chart review. A referral center for pediatric cochlear implantation and rehabilitation. Thirty children with cochlear implants who were deafened by meningitis were matched with subjects who were deafened by other causes based on the age at diagnosis, age at cochlear implantation, age at which hearing aids were first used, and method of communication used at home or in the classroom. Speech perception performance within the first 2 years after cochlear implantation and its relationship with presurgical cognitive measures and medical history. There was no difference in the overall cognitive or postoperative speech perception performance between the children with PMD and those deafened by other causes. The presence of postmeningitic hydrocephalus, however, posed greater challenges to the rehabilitation process, as indicated by significantly smaller gains in speech perception and a predilection for behavioral problems. By comparison, cochlear scarring and incomplete electrode insertion had no impact on speech perception results. Although the results demonstrated no significant delay in cognitive or speech perception performance in the PMD group, central nervous system residua, when present, can impede the acquisition of speech perception with a cochlear implant. Central effects associated with PMD may thus impact language learning potential; cognitive and behavioral therapy should be considered in rehabilitative planning and in establishing expectations of outcome.
Cochlear implantation for single-sided deafness and tinnitus suppression.
Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George
To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.
Chertoff, Mark E.; Earl, Brian R.; Diaz, Francisco J.; Sorensen, Janna L.; Thomas, Megan L. A.; Kamerer, Aryn M.; Peppi, Marcello
2014-01-01
The electrical signal recorded at the round window was used to estimate the location of missing outer hair cells. The cochlear response was recorded to a low frequency tone embedded in high-pass filtered noise conditions. Cochlear damage was created by either overexposure to frequency-specific tones or laser light. In animals with continuous damage along the partition, the amplitude of the cochlear response increased as the high-pass cutoff frequency increased, eventually reaching a plateau. The cochlear distance at the onset of the plateau correlated with the anatomical onset of outer hair cell loss. A mathematical model replicated the physiologic data but was limited to cases with continuous hair cell loss in the middle and basal turns. The neural contribution to the cochlear response was determined by recording the response before and after application of Ouabain. Application of Ouabain eliminated or reduced auditory neural activity from approximately two turns of the cochlea. The amplitude of the cochlear response was reduced for moderate signal levels with a limited effect at higher levels, indicating that the cochlear response was dominated by outer hair cell currents at high signal levels and neural potentials at low to moderate signal levels. PMID:25190395
Patel, Tirth R; Shahin, Antoine J; Bhat, Jyoti; Welling, D Bradley; Moberly, Aaron C
2016-10-01
We describe a novel use of cortical auditory evoked potentials in the preoperative workup to determine ear candidacy for cochlear implantation. A 71-year-old male was evaluated who had a long-deafened right ear, had never worn a hearing aid in that ear, and relied heavily on use of a left-sided hearing aid. Electroencephalographic testing was performed using free field auditory stimulation of each ear independently with pure tones at 1000 and 2000 Hz at approximately 10 dB above pure-tone thresholds for each frequency and for each ear. Mature cortical potentials were identified through auditory stimulation of the long-deafened ear. The patient underwent successful implantation of that ear. He experienced progressively improving aided pure-tone thresholds and binaural speech recognition benefit (AzBio score of 74%). Findings suggest that use of cortical auditory evoked potentials may serve a preoperative role in ear selection prior to cochlear implantation. © The Author(s) 2016.
Optimization of Microphone Locations for Acoustic Liner Impedance Eduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.; June, J. C.
2015-01-01
Two impedance eduction methods are explored for use with data acquired in the NASA Langley Grazing Flow Impedance Tube. The first is an indirect method based on the convected Helmholtz equation, and the second is a direct method based on the Kumaresan and Tufts algorithm. Synthesized no-flow data, with random jitter to represent measurement error, are used to evaluate a number of possible microphone locations. Statistical approaches are used to evaluate the suitability of each set of microphone locations. Given the computational resources required, small sample statistics are employed for the indirect method. Since the direct method is much less computationally intensive, a Monte Carlo approach is employed to gather its statistics. A comparison of results achieved with full and reduced sets of microphone locations is used to determine which sets of microphone locations are acceptable. For the indirect method, each array that includes microphones in all three regions (upstream and downstream hard wall sections, and liner test section) provides acceptable results, even when as few as eight microphones are employed. The best arrays employ microphones well away from the leading and trailing edges of the liner. The direct method is constrained to use microphones opposite the liner. Although a number of arrays are acceptable, the optimum set employs 14 microphones positioned well away from the leading and trailing edges of the liner. The selected sets of microphone locations are also evaluated with data measured for ceramic tubular and perforate-over-honeycomb liners at three flow conditions (Mach 0.0, 0.3, and 0.5). They compare favorably with results attained using all 53 microphone locations. Although different optimum microphone locations are selected for the two impedance eduction methods, there is significant overlap. Thus, the union of these two microphone arrays is preferred, as it supports usage of both methods. This array contains 3 microphones in the upstream hard wall section, 14 microphones opposite the liner, and 3 microphones in the downstream hard wall section.
Park, Edward; Amoodi, Hosam; Kuthubutheen, Jafri; Chen, Joseph M; Nedzelski, Julian M; Lin, Vincent Y W
2015-05-28
Cochlear implantation has become a mainstream treatment option for patients with severe to profound sensorineural hearing loss. During cochlear implant, there are key surgical steps which are influenced by anatomical variations between each patient. The aim of this study is to determine if there are potential predictors of difficulties that may be encountered during the cortical mastoidectomy, facial recess approach and round window access in cochlear implant surgery based upon pre-operative temporal bone CT scan. Fifty seven patients undergoing unilateral cochlear implantation were analyzed. Difficulty with 1) cortical mastoidectomy, 2) facial recess approach, and 3) round window access were scored intra-operatively by the surgeon in a blinded fashion (1 = "easy", 2 = "moderate", 3 = "difficult"). Pre-operative temporal bone CT scans were analyzed for 1) degree of mastoid aeration; 2) location of the sigmoid sinus; 3) height of the tegmen; 4) the presence of air cells in the facial recess, and 5) degree of round window bony overhang. Poor mastoid aeration and lower tegmen position, but not the location of sigmoid sinus, are associated with greater difficulty with the cortical mastoidectomy. Presence of an air cell around the facial nerve was predictive of easier facial recess access. However, the degree of round window bony overhang was not predictive of difficulty associated with round window access. Certain parameters on the pre-operative temporal bone CT scan may be useful in predicting potential difficulties encountered during the key steps involved in cochlear implant surgery.
ERIC Educational Resources Information Center
Cherney, James L.
1999-01-01
Examines the potential benefits and limitations of cyborg politics. Explores depictions of cyborgs in science fiction stories and examines the deaf culture's arguments in the cochlear-implant debate. Investigates the current viability of cyborg politics as a mode of advocacy for people with disabilities. (SC)
Changing Realities in the Classroom for Hearing-Impaired Children with Cochlear Implant
ERIC Educational Resources Information Center
Vermeulen, Anneke; De Raeve, Leo; Langereis, Margreet; Snik, Ad
2012-01-01
Auditory perception with cochlear implants (CIs) enables the majority of deaf children with normal learning potential to develop (near) age-appropriate spoken language. As a consequence, a large proportion of children now attend mainstream education from an early stage. The acoustical environment in kindergartens and schools, however, might be…
Corticofugal modulation of peripheral auditory responses
Terreros, Gonzalo; Delano, Paul H.
2015-01-01
The auditory efferent system originates in the auditory cortex and projects to the medial geniculate body (MGB), inferior colliculus (IC), cochlear nucleus (CN) and superior olivary complex (SOC) reaching the cochlea through olivocochlear (OC) fibers. This unique neuronal network is organized in several afferent-efferent feedback loops including: the (i) colliculo-thalamic-cortico-collicular; (ii) cortico-(collicular)-OC; and (iii) cortico-(collicular)-CN pathways. Recent experiments demonstrate that blocking ongoing auditory-cortex activity with pharmacological and physical methods modulates the amplitude of cochlear potentials. In addition, auditory-cortex microstimulation independently modulates cochlear sensitivity and the strength of the OC reflex. In this mini-review, anatomical and physiological evidence supporting the presence of a functional efferent network from the auditory cortex to the cochlear receptor is presented. Special emphasis is given to the corticofugal effects on initial auditory processing, that is, on CN, auditory nerve and cochlear responses. A working model of three parallel pathways from the auditory cortex to the cochlea and auditory nerve is proposed. PMID:26483647
NASA Astrophysics Data System (ADS)
Dumoulin, Romain
Despite the fact that noise-induced hearing loss remains the number one occupational disease in developed countries, individual noise exposure levels are still rarely known and infrequently tracked. Indeed, efforts to standardize noise exposure levels present disadvantages such as costly instrumentation and difficulties associated with on site implementation. Given their advanced technical capabilities and widespread daily usage, mobile phones could be used to measure noise levels and make noise monitoring more accessible. However, the use of mobile phones for measuring noise exposure is currently limited due to the lack of formal procedures for their calibration and challenges regarding the measurement procedure. Our research investigated the calibration of mobile phone-based solutions for measuring noise exposure using a mobile phone's built-in microphones and wearable external microphones. The proposed calibration approach integrated corrections that took into account microphone placement error. The corrections were of two types: frequency-dependent, using a digital filter and noise level-dependent, based on the difference between the C-weighted noise level minus A-weighted noise level of the noise measured by the phone. The electro-acoustical limitations and measurement calibration procedure of the mobile phone were investigated. The study also sought to quantify the effect of noise exposure characteristics on the accuracy of calibrated mobile phone measurements. Measurements were carried out in reverberant and semi-anechoic chambers with several mobiles phone units of the same model, two types of external devices (an earpiece and a headset with an in-line microphone) and an acoustical test fixture (ATF). The proposed calibration approach significantly improved the accuracy of the noise level measurements in diffuse and free fields, with better results in the diffuse field and with ATF positions causing little or no acoustic shadowing. Several sources of errors and uncertainties were identified including the errors associated with the inter-unit-variability, the presence of signal saturation and the microphone placement relative to the source and the wearer. The results of the investigations and validation measurements led to recommendations regarding the measurement procedure including the use of external microphones having lower sensitivity and provided the basis for a standardized and unique factory default calibration method intended for implementation in any mobile phone. A user-defined adjustment was proposed to minimize the errors associated with calibration and the acoustical field. Mobile phones implementing the proposed laboratory calibration and used with external microphones showed great potential as noise exposure instruments. Combined with their potential as training and prevention tools, the expansion of their use could significantly help reduce the risks of noise-induced hearing loss.
High sensitivity capacitive MEMS microphone with spring supported diaphragm
NASA Astrophysics Data System (ADS)
Mohamad, Norizan; Iovenitti, Pio; Vinay, Thurai
2007-12-01
Capacitive microphones (condenser microphones) work on a principle of variable capacitance and voltage by the movement of its electrically charged diaphragm and back plate in response to sound pressure. There has been considerable research carried out to increase the sensing performance of microphones while reducing their size to cater for various modern applications such as mobile communication and hearing aid devices. This paper reviews the development and current performance of several condenser MEMS microphone designs, and introduces a microphone with spring supported diaphragm to further improve condenser microphone performance. The numerical analysis using Coventor FEM software shows that this new microphone design has a higher mechanical sensitivity compared to the existing edge clamped flat diaphragm condenser MEMS microphone. The spring supported diaphragm is shown to have a flat frequency response up to 7 kHz and more stable under the variations of the diaphragm residual stress. The microphone is designed to be easily fabricated using the existing silicon fabrication technology and the stability against the residual stress increases its reproducibility.
Mandalà, Marco; Colletti, Liliana; Colletti, Giacomo; Colletti, Vittorio
2014-12-01
To compare the outcomes (auditory threshold and open-set speech perception at 48-month follow-up) of a new near-field monitoring procedure, electrical compound action potential, on positioning the auditory brainstem implant electrode array on the surface of the cochlear nuclei versus the traditional far-field electrical auditory brainstem response. Retrospective study. Tertiary referral center. Among the 202 patients with auditory brainstem implants fitted and monitored with electrical auditory brainstem response during implant fitting, 9 also underwent electrical compound action potential recording. These subjects were matched retrospectively with a control group of 9 patients in whom only the electrical auditory brainstem response was recorded. Electrical compound action potentials were obtained using a cotton-wick recording electrode located near the surface of the cochlear nuclei and on several cranial nerves. Significantly lower potential thresholds were observed with the recording electrode located on the cochlear nuclei surface compared with the electrical auditory brainstem response (104.4 ± 32.5 vs 158.9 ± 24.2, P = .0030). Electrical brainstem response and compound action potentials identified effects on the neighboring cranial nerves on 3.2 ± 2.4 and 7.8 ± 3.2 electrodes, respectively (P = .0034). Open-set speech perception outcomes at 48-month follow-up had improved significantly in the near- versus far-field recording groups (78.9% versus 56.7%; P = .0051). Electrical compound action potentials during auditory brainstem implantation significantly improved the definition of the potential threshold and the number of auditory and extra-auditory waves generated. It led to the best coupling between the electrode array and cochlear nuclei, significantly improving the overall open-set speech perception. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.
Cochlear implants and spoken language processing abilities: review and assessment of the literature.
Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T
2010-01-01
Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.
Chen, Hanchi; Abhayapala, Thushara D; Zhang, Wen
2015-11-01
Soundfield analysis based on spherical harmonic decomposition has been widely used in various applications; however, a drawback is the three-dimensional geometry of the microphone arrays. In this paper, a method to design two-dimensional planar microphone arrays that are capable of capturing three-dimensional (3D) spatial soundfields is proposed. Through the utilization of both omni-directional and first order microphones, the proposed microphone array is capable of measuring soundfield components that are undetectable to conventional planar omni-directional microphone arrays, thus providing the same functionality as 3D arrays designed for the same purpose. Simulations show that the accuracy of the planar microphone array is comparable to traditional spherical microphone arrays. Due to its compact shape, the proposed microphone array greatly increases the feasibility of 3D soundfield analysis techniques in real-world applications.
Background noise levels measured in the NASA Lewis 9- by 15-foot low-speed wind tunnel
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Dittmar, James H.; Hall, David G.; Kee-Bowling, Bonnie
1994-01-01
The acoustic capability of the NASA Lewis 9 by 15 Foot Low Speed Wind Tunnel has been significantly improved by reducing the background noise levels measured by in-flow microphones. This was accomplished by incorporating streamlined microphone holders having a profile developed by researchers at the NASA Ames Research Center. These new holders were fabricated for fixed mounting on the tunnel wall and for an axially traversing microphone probe which was mounted to the tunnel floor. Measured in-flow noise levels in the tunnel test section were reduced by about 10 dB with the new microphone holders compared with those measured with the older, less refined microphone holders. Wake interference patterns between fixed wall microphones were measured and resulted in preferred placement patterns for these microphones to minimize these effects. Acoustic data from a model turbofan operating in the tunnel test section showed that results for the fixed and translating microphones were equivalent for common azimuthal angles, suggesting that the translating microphone probe, with its significantly greater angular resolution, is preferred for sideline noise measurements. Fixed microphones can provide a local check on the traversing microphone data quality, and record acoustic performance at other azimuthal angles.
Speech intelligibility in noise using throat and acoustic microphones.
Acker-Mills, Barbara E; Houtsma, Adrianus J M; Ahroon, William A
2006-01-01
Helicopter cockpits are very noisy and this noise must be reduced for effective communication. The standard U.S. Army aviation helmet is equipped with a noise-canceling acoustic microphone, but some ambient noise still is transmitted. Throat microphones are not sensitive to air molecule vibrations and thus, transmittal of ambient noise is reduced. It is possible that throat microphones could enhance speech communication in helicopters, but speech intelligibility with the devices must first be assessed. In the current study, speech intelligibility of signals generated by an acoustic microphone, a throat microphone, and by the combined output of the two microphones was assessed using the Modified Rhyme Test (MRT). Stimulus words were recorded in a reverberant chamber with ambient broadband noise intensity at 90 and 106 dBA. Listeners completed the MRT task in the same settings, thus simulating the typical environment of a rotary-wing aircraft. Results show that speech intelligibility is significantly worse for the throat microphone (average percent correct = 55.97) than for the acoustic microphone (average percent correct = 69.70), particularly for the higher noise level. In addition, no benefit is gained by simultaneously using both microphones. A follow-up experiment evaluated different consonants using the Diagnostic Rhyme Test and replicated the MRT results. The current results show that intelligibility using throat microphones is poorer than with the use of boom microphones in noisy and in quiet environments. Therefore, throat microphones are not recommended for use in any situation where fast and accurate speech intelligibility is essential.
Eckhard, A; Löwenheim, H
2014-06-01
Sound transduction in the cochlea critically depends on the circulation of potassium ions (K(+)) along so-called "K(+) recycling routes" between the endolymph and perilymph. These K(+) currents generate high ionic and osmotic gradients, which potentially impair the excitability of sensory hair cells and threaten cell survival in the entire cochlear duct. Molecular water channels-aquaporins (AQP)-are expressed in all cochlear supporting cells along the K(+) recycling routes; however, their significance for osmotic equilibration in cochlear duct cells is unknown. The diffusive and osmotic water permeabilies of Reissner's membrane, the organ of Corti and the entire cochlear duct epithelium were determined. Expression of the potassium channel Kir4.1 and the water channel AQP4 in the cochlear duct was investigated by immunohistochemistry. The calculated water permeability values indicate the extent of AQP-facilitated water flux across the cochlear duct epithelium. Immunohistochemically, Kir4.1 and AQP4 were found to colocalize in distinct membrane domains of supporting cells along the K(+)-recycling routes. These observations suggest the presence of a rapid AQP-mediated water exchange between the endolymph, the cells of the cochlear duct and the perilymph. The subcellular colocalization of Kir4.1 and AQP4 in epithelial supporting cells indicates functional coupling of potassium and water flow in the cochlea. Finally, this offers an explanation for the hearing impairment observed in individuals with mutations in the AQP4 gene.
Probst, Frank J.; Corrigan, Rebecca R.; del Gaudio, Daniela; Salinger, Andrew P.; Lorenzo, Isabel; Gao, Simon S.; Chiu, Ilene; Xia, Anping
2013-01-01
The study of mouse hearing impairment mutants has led to the identification of a number of human hearing impairment genes and has greatly furthered our understanding of the physiology of hearing. The novel mouse mutant neurological/sensory 5 (nse5) demonstrates a significantly reduced or absent startle response to sound and is therefore a potential murine model of human hearing impairment. Genetic analysis of 500 intercross progeny localized the mutant locus to a 524 kilobase (kb) interval on mouse chromosome 15. A missense mutation in a highly-conserved amino acid was found in the asparagine-linked glycosylation 10B gene (Alg10b), which is within the critical interval for the nse5 mutation. A 20.4 kb transgene containing a wildtype copy of the Alg10b gene rescued the mutant phenotype in nse5/nse5 homozygous animals, confirming that the mutation in Alg10b is responsible for the nse5/nse5 mutant phenotype. Homozygous nse5/nse5 mutants had abnormal auditory brainstem responses (ABRs), distortion product otoacoustic emissions (DPOAEs), and cochlear microphonics (CMs). Endocochlear potentials (EPs), on the other hand, were normal. ABRs and DPOAEs also confirmed the rescue of the mutant nse5/nse5 phenotype by the wildtype Alg10b transgene. These results suggested a defect in the outer hair cells of mutant animals, which was confirmed by histologic analysis. This is the first report of mutation in a gene involved in the asparagine (N)-linked glycosylation pathway causing nonsyndromic hearing impairment, and it suggests that the hearing apparatus, and the outer hair cells in particular, are exquisitely sensitive to perturbations of the N-linked glycosylation pathway. PMID:24303013
Cerebellar interaction with the acoustic reflex.
Jastreboff, P J
1981-01-01
The involvement of the cerebellar vermis in the acoustic reflex was analyzed in 12 cats, decerebrated or in pentobarbital anesthesia. Anatomical data suggested the existence of a connection of lobules VIII with the ventral cochlear nucleus. Single cell recording and evoked potential techniques demonstrated the existence of the acoustic projection to lobulus VIII. Electrical stimulation of this area changed the tension of the middle ear muscle and caused evoked potential responses in the caudal part of the ventral cochlear nucleus. Electrical stimulation of the motor nucleus of the facial nerve evoked a slow wave in the recording taken from the surrounding of the cochlear round window. A hypothesis is proposed which postulates the involvement of the acoustic reflex in space localization of acoustic stimuli and the action of cerebellar vermis in order to assure the stability and plasticity of the acoustic reflex arc.
Graham, Christine E.; Basappa, Johnvesly; Turcan, Sevin; Vetter, Douglas E.
2011-01-01
A key requirement for encoding the auditory environment is the ability to dynamically alter cochlear sensitivity. However, merely attaining a steady state of maximal sensitivity is not a viable solution since the sensory cells and ganglion cells of the cochlea are prone to damage following exposure to loud sound. Most often, such damage is via initial metabolic insult that can lead to cellular death. Thus, establishing the highest sensitivity must be balanced with protection against cellular metabolic damage that can lead to loss of hair cells and ganglion cells, resulting in loss of frequency representation. While feedback mechanisms are known to exist in the cochlea that alter sensitivity, they respond only after stimulus encoding, allowing potentially damaging sounds to impact the inner ear at times coincident with increased sensitivity. Thus, questions remain concerning the endogenous signaling systems involved in dynamic modulation of cochlear sensitivity and protection against metabolic stress. Understanding endogenous signaling systems involved in cochlear protection may lead to new strategies and therapies for prevention of cochlear damage and consequent hearing loss. We have recently discovered a novel cochlear signaling system that is molecularly equivalent to the classic hypothalamic-pituitary-adrenal (HPA) axis. This cochlear HPA-equivalent system functions to balance auditory sensitivity and susceptibility to noise-induced hearing loss, and also protects against cellular metabolic insults resulting from exposures to ototoxic drugs. We review the anatomy, physiology, and cellular signaling of this system, and compare it to similar signaling in other organs/tissues of the body. PMID:21909974
Calibration of High Frequency MEMS Microphones
NASA Technical Reports Server (NTRS)
Shams, Qamar A.; Humphreys, William M.; Bartram, Scott M.; Zuckewar, Allan J.
2007-01-01
Understanding and controlling aircraft noise is one of the major research topics of the NASA Fundamental Aeronautics Program. One of the measurement technologies used to acquire noise data is the microphone directional array (DA). Traditional direction array hardware, consisting of commercially available condenser microphones and preamplifiers can be too expensive and their installation in hard-walled wind tunnel test sections too complicated. An emerging micro-machining technology coupled with the latest cutting edge technologies for smaller and faster systems have opened the way for development of MEMS microphones. The MEMS microphone devices are available in the market but suffer from certain important shortcomings. Based on early experiments with array prototypes, it has been found that both the bandwidth and the sound pressure level dynamic range of the microphones should be increased significantly to improve the performance and flexibility of the overall array. Thus, in collaboration with an outside MEMS design vendor, NASA Langley modified commercially available MEMS microphone as shown in Figure 1 to meet the new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Over the years, several methods have been used for microphone calibration. Some of the common methods of microphone calibration are Coupler (Reciprocity, Substitution, and Simultaneous), Pistonphone, Electrostatic actuator, and Free-field calibration (Reciprocity, Substitution, and Simultaneous). Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones for wideband frequency ranges; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size. Hence a substitution-based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone.
A combined microphone and camera calibration technique with application to acoustic imaging.
Legg, Mathew; Bradley, Stuart
2013-10-01
We present a calibration technique for an acoustic imaging microphone array, combined with a digital camera. Computer vision and acoustic time of arrival data are used to obtain microphone coordinates in the camera reference frame. Our new method allows acoustic maps to be plotted onto the camera images without the need for additional camera alignment or calibration. Microphones and cameras may be placed in an ad-hoc arrangement and, after calibration, the coordinates of the microphones are known in the reference frame of a camera in the array. No prior knowledge of microphone positions, inter-microphone spacings, or air temperature is required. This technique is applied to a spherical microphone array and a mean difference of 3 mm was obtained between the coordinates obtained with this calibration technique and those measured using a precision mechanical method.
Posatskiy, A O; Chau, T
2012-04-01
Mechanomyography (MMG) is an important kinesiological tool and potential communication pathway for individuals with disabilities. However, MMG is highly susceptible to contamination by motion artifact due to limb movement. A better understanding of the nature of this contamination and its effects on different sensing methods is required to inform robust MMG sensor design. Therefore, in this study, we recorded MMG from the extensor carpi ulnaris of six able-bodied participants using three different co-located condenser microphone and accelerometer pairings. Contractions at 30% MVC were recorded with and without a shaker-induced single-frequency forearm motion artifact delivered via a custom test rig. Using a signal-to-signal-plus-noise-ratio and the adaptive Neyman curve-based statistic, we found that microphone-derived MMG spectra were significantly less influenced by motion artifact than corresponding accelerometer-derived spectra (p⩽0.05). However, non-vanishing motion artifact harmonics were present in both spectra, suggesting that simple bandpass filtering may not remove artifact influences permeating into typical MMG bands of interest. Our results suggest that condenser microphones are preferred for MMG recordings when the mitigation of motion artifact effects is important. Copyright © 2011. Published by Elsevier Ltd.
Theoretical and experimental study of a fiber optic microphone
NASA Technical Reports Server (NTRS)
Hu, Andong; Cuomo, Frank W.; Zuckerwar, Allan J.
1992-01-01
Modifications to condenser microphone theory yield new expressions for the membrane deflections at its center, which provide the basic theory for the fiber optic microphone. The theoretical analysis for the membrane amplitude and the phase response of the fiber optic microphone is given in detail in terms of its basic geometrical quantities. A relevant extension to the original concepts of the optical microphone includes the addition of a backplate with holes similar in design to present condenser microphone technology. This approach generates improved damping characteristics and extended frequency response that were not previously considered. The construction and testing of the improved optical fiber microphone provide experimental data that are in good agreement with the theoretical analysis.
Gillespie, Lisa N; Zanin, Mark P; Shepherd, Robert K
2015-01-28
The cochlear implant provides auditory cues to profoundly deaf patients by electrically stimulating the primary auditory neurons (ANs) of the cochlea. However, ANs degenerate in deafness; the preservation of a robust AN target population, in combination with advances in cochlear implant technology, may provide improved hearing outcomes for cochlear implant patients. The exogenous delivery of neurotrophins such as brain-derived neurotrophic factor (BDNF) and neurotrophin-3 is well known to support AN survival in deafness, and cell-based therapies provide a potential clinically viable option for delivering neurotrophins into the deaf cochlea. This study utilized cells that were genetically modified to express BDNF and encapsulated in alginate microspheres, and investigated AN survival in the deaf guinea pig following (a) cell-based neurotrophin treatment in conjunction with chronic electrical stimulation from a cochlear implant, and (b) long-term cell-based neurotrophin delivery. In comparison to deafened controls, there was significantly greater AN survival following the cell-based neurotrophin treatment, and there were ongoing survival effects for at least six months. In addition, functional benefits were observed following cell-based neurotrophin treatment and chronic electrical stimulation, with a statistically significant decrease in electrically evoked auditory brainstem response thresholds observed during the experimental period. This study demonstrates that cell-based therapies, in conjunction with a cochlear implant, shows potential as a clinically transferable means of providing neurotrophin treatment to support AN survival in deafness. This technology also has the potential to deliver other therapeutic agents, and to be used in conjunction with other biomedical devices for the treatment of a variety of neurodegenerative conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
Benefits of the fiber optic versus the electret microphone in voice amplification.
Kyriakou, Kyriaki; Fisher, Hélène R
2013-01-01
Voice disorders that result in reduced loudness may cause difficulty in communicating, socializing and participating in occupational activities. Amplification is often recommended in order to facilitate functional communication, reduce vocal load and avoid developing maladaptive compensatory behaviours. The most common microphone used with amplification systems is the electret microphone. One alternate form of microphone is the fiber optic microphone. To examine the benefits of the fiber optic (1190S) versus the electret (M04) microphone as measured by objective and subjective parameters in the amplification of a patient's voice with reduced loudness caused by neurological and/or respiratory-based problems. Eighteen patients with vocal fold paralysis, Parkinson's disease and/or chronic obstructive pulmonary disease (COPD) participated in the study. The study contained a measurement of intensity, amplitude perturbation and signal-to-noise ratio during a sustained vowel production and a measurement of intensity during conversation with the use of the two microphones simultaneously. It also included the completion of a questionnaire indicating the patient's satisfaction with each microphone. The fiber optic (1190S) microphone had better objective acoustic performance (i.e. lower amplitude perturbation, higher signal-to-noise ratio and higher intensity) than the electret (M04) microphone. It also had better patient subjective satisfaction (i.e. less conspicuousness, more voice clarity, less acoustic feedback, more loudness and more utilization) than the electret microphone. Patients with neurological and/or respiratory-based voice problems may more confidently and frequently use the fiber optic microphone to communicate, socialize and participate in occupational activities more easily. Speech-language pathologists may more confidently use or recommend the fiber optic microphone with amplification systems. © 2012 Royal College of Speech and Language Therapists.
Crukley, Jeffery; Scollie, Susan D
2014-03-01
The purpose of this study was to determine the effects of hearing instruments set to Desired Sensation Level version 5 (DSL v5) hearing instrument prescription algorithm targets and equipped with directional microphones and digital noise reduction (DNR) on children's sentence recognition in noise performance and loudness perception in a classroom environment. Ten children (ages 8-17 years) with stable, congenital sensorineural hearing losses participated in the study. Participants were fitted bilaterally with behind-the-ear hearing instruments set to DSL v5 prescriptive targets. Sentence recognition in noise was evaluated using the Bamford-Kowal-Bench Speech in Noise Test (Niquette et al., 2003). Loudness perception was evaluated using a modified version of the Contour Test of Loudness Perception (Cox, Alexander, Taylor, & Gray, 1997). Children's sentence recognition in noise performance was significantly better when using directional microphones alone or in combination with DNR than when using omnidirectional microphones alone or in combination with DNR. Children's loudness ratings for sounds above 72 dB SPL were lowest when fitted with the DSL v5 Noise prescription combined with directional microphones. DNR use showed no effect on loudness ratings. Use of the DSL v5 Noise prescription with a directional microphone improved sentence recognition in noise performance and reduced loudness perception ratings for loud sounds relative to a typical clinical reference fitting with the DSL v5 Quiet prescription with no digital signal processing features enabled. Potential clinical strategies are discussed.
Valente, Michael; Mispagel, Karen M; Tchorz, Juergen; Fabry, David
2006-06-01
Differences in performance between omnidirectional and directional microphones were evaluated between two loudspeaker conditions (single loudspeaker at 180 degrees; diffuse using eight loudspeakers set 45 degrees apart) and two types of noise (steady-state HINT noise; R-Space restaurant noise). Twenty-five participants were fit bilaterally with Phonak Perseo hearing aids using the manufacturer's recommended procedure. After wearing the hearing aids for one week, the parameters were fine-tuned based on subjective comments. Four weeks later, differences in performance between omnidirectional and directional microphones were assessed using HINT sentences presented at 0 degrees with the two types of background noise held constant at 65 dBA and under the two loudspeaker conditions. Results revealed significant differences in Reception Thresholds for Sentences (RTS in dB) where directional performance was significantly better than omnidirectional. Performance in the 180 degrees condition was significantly better than the diffuse condition, and performance was significantly better using the HINT noise in comparison to the R-Space restaurant noise. In addition, results revealed that within each loudspeaker array, performance was significantly better for the directional microphone. Looking across loudspeaker arrays, however, significant differences were not present in omnidirectional performance, but directional performance was significantly better in the 180 degrees condition when compared to the diffuse condition. These findings are discussed in terms of results reported in the past and counseling patients on the potential advantages of directional microphones as the listening situation and type of noise changes.
Truck acoustic data analyzer system
Haynes, Howard D.; Akerman, Alfred; Ayers, Curtis W.
2006-07-04
A passive vehicle acoustic data analyzer system having at least one microphone disposed in the acoustic field of a moving vehicle and a computer in electronic communication the microphone(s). The computer detects and measures the frequency shift in the acoustic signature emitted by the vehicle as it approaches and passes the microphone(s). The acoustic signature of a truck driving by a microphone can provide enough information to estimate the truck speed in miles-per-hour (mph), engine speed in rotations-per-minute (RPM), turbocharger speed in RPM, and vehicle weight.
Li, Wei; Torres, David; Díaz, Ramón; Wang, Zhengjun; Wu, Changsheng; Wang, Chuan; Lin Wang, Zhong; Sepúlveda, Nelson
2017-05-16
Ferroelectret nanogenerators were recently introduced as a promising alternative technology for harvesting kinetic energy. Here we report the device's intrinsic properties that allow for the bidirectional conversion of energy between electrical and mechanical domains; thus extending its potential use in wearable electronics beyond the power generation realm. This electromechanical coupling, combined with their flexibility and thin film-like form, bestows dual-functional transducing capabilities to the device that are used in this work to demonstrate its use as a thin, wearable and self-powered loudspeaker or microphone patch. To determine the device's performance and applicability, sound pressure level is characterized in both space and frequency domains for three different configurations. The confirmed device's high performance is further validated through its integration in three different systems: a music-playing flag, a sound recording film and a flexible microphone for security applications.
NASA Astrophysics Data System (ADS)
Li, Wei; Torres, David; Díaz, Ramón; Wang, Zhengjun; Wu, Changsheng; Wang, Chuan; Lin Wang, Zhong; Sepúlveda, Nelson
2017-05-01
Ferroelectret nanogenerators were recently introduced as a promising alternative technology for harvesting kinetic energy. Here we report the device's intrinsic properties that allow for the bidirectional conversion of energy between electrical and mechanical domains; thus extending its potential use in wearable electronics beyond the power generation realm. This electromechanical coupling, combined with their flexibility and thin film-like form, bestows dual-functional transducing capabilities to the device that are used in this work to demonstrate its use as a thin, wearable and self-powered loudspeaker or microphone patch. To determine the device's performance and applicability, sound pressure level is characterized in both space and frequency domains for three different configurations. The confirmed device's high performance is further validated through its integration in three different systems: a music-playing flag, a sound recording film and a flexible microphone for security applications.
Li, Wei; Torres, David; Díaz, Ramón; Wang, Zhengjun; Wu, Changsheng; Wang, Chuan; Lin Wang, Zhong; Sepúlveda, Nelson
2017-01-01
Ferroelectret nanogenerators were recently introduced as a promising alternative technology for harvesting kinetic energy. Here we report the device's intrinsic properties that allow for the bidirectional conversion of energy between electrical and mechanical domains; thus extending its potential use in wearable electronics beyond the power generation realm. This electromechanical coupling, combined with their flexibility and thin film-like form, bestows dual-functional transducing capabilities to the device that are used in this work to demonstrate its use as a thin, wearable and self-powered loudspeaker or microphone patch. To determine the device's performance and applicability, sound pressure level is characterized in both space and frequency domains for three different configurations. The confirmed device's high performance is further validated through its integration in three different systems: a music-playing flag, a sound recording film and a flexible microphone for security applications. PMID:28508862
Tinnitus and Sleep Difficulties After Cochlear Implantation.
Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T
To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p < 0.001). Self-reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p < 0.001). The prevalence of sleep difficulties was not related to tinnitus persistence (p = 0.28) or the extent to which tinnitus was distressing (p = 0.55). The lack of association between tinnitus persistence and sleep difficulties is compatible with the notion that tinnitus is suppressed in implant users primarily during active electrical stimulation and may return when the implant is switched off at night time. This explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention where the primary aim is to alleviate sleep difficulties.
de Vos, Johan J; Biesheuvel, Jan Dirk; Briaire, Jeroen J; Boot, Pieter S; van Gendt, Margriet J; Dekkers, Olaf M; Fiocco, Marta; Frijns, Johan H M
The electrically evoked compound action potential (eCAP) is widely used in the clinic as an objective measure to assess cochlear implant functionality. During the past decade, there has been increasing interest in applying eCAPs for fitting of cochlear implants. Several studies have shown that eCAP-based fitting can potentially replace time-consuming behavioral fitting procedures, especially in young children. However, a closer look to all available literature revealed that there is no clear consensus on the validity of this fitting procedure. This study evaluated the validity of eCAP-based fitting of cochlear implant recipients based on a systematic review of the recent literature. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses were used to search the PubMed, Web of Science, and Cochrane Library databases. The term "eCAP" was combined with "cochlear implants," "thresholds," and "levels," in addition to a range of related terms. Finally, 32 studies met the inclusion criteria. These studies were evaluated on the risk of bias and, when possible, compared by meta-analysis. Almost all assessed studies suffered from some form of risk of bias. Twenty-nine of the studies based their conclusion on a group correlation instead of individual subject correlations (analytical bias); 14 studies were unclear about randomization or blinding (outcome assessment bias); 9 studies provided no clear description of the populations used, for example, prelingually or postlingually implanted subjects (selection bias); and 4 studies had a high rate of loss (>10%) for patients or electrodes (attrition bias). Meta-analysis of these studies revealed a weak pooled correlation between eCAP thresholds and both behavioral T- and C-levels (r = 0.58 and r = 0.61, respectively). This review shows that the majority of the assessed studies suffered from substantial shortcomings in study design and statistical analysis. Meta-analysis showed that there is only weak evidence to support the use of eCAP data for cochlear implant fitting purposes; eCAP thresholds are an equally weak predictor for both T- and C-levels. Based on this review, it can be concluded that research on eCAP-based fitting needs a profound reflection on study design and analysis to draw well-grounded conclusions about the validity of eCAP-based fitting of cochlear implant recipients.
ERIC Educational Resources Information Center
Leigh, Irene W.; Maxwell-McCaw, Deborah; Bat-Chava, Yael; Christiansen, John B.
2009-01-01
The number of children who have received cochlear implants (CIs) has increased dramatically in the past two decades. In view of potential concerns about their psychosocial adjustment, our aim was to assess the effect of implants on the adolescents' psychosocial functioning among a group of 57 deaf adolescents with and without CIs, using published…
Design and development of second order MEMS sound pressure gradient sensor
NASA Astrophysics Data System (ADS)
Albahri, Shehab
The design and development of a second order MEMS sound pressure gradient sensor is presented in this dissertation. Inspired by the directional hearing ability of the parasitoid fly, Ormia ochracea, a novel first order directional microphone that mimics the mechanical structure of the fly's ears and detects the sound pressure gradient has been developed. While the first order directional microphones can be very beneficial in a large number of applications, there is great potential for remarkable improvements in performance through the use of second order systems. The second order directional microphone is able to provide a theoretical improvement in Sound to Noise ratio (SNR) of 9.5dB, compared to the first-order system that has its maximum SNR of 6dB. Although second order microphone is more sensitive to sound angle of incidence, the nature of the design and fabrication process imposes different factors that could lead to deterioration in its performance. The first Ormia ochracea second order directional microphone was designed in 2004 and fabricated in 2006 at Binghamton University. The results of the tested parts indicate that the Ormia ochracea second order directional microphone performs mostly as an Omni directional microphone. In this work, the previous design is reexamined and analyzed to explain the unexpected results. A more sophisticated tool implementing a finite element package ANSYS is used to examine the previous design response. This new tool is used to study different factors that used to be ignored in the previous design, mainly; response mismatch and fabrication uncertainty. A continuous model using Hamilton's principle is introduced to verify the results using the new method. Both models agree well, and propose a new way for optimizing the second order directional microphone using geometrical manipulation. In this work we also introduce a new fabrication process flow to increase the fabrication yield. The newly suggested method uses the shell layered analysis method in ANSYS. The developed models simulate the fabricated chips at different stages; with the stress at each layer is introduced using thermal loading. The results indicate a new fabrication process flow to increase the rigidity of the composite layers, and countering the deformation caused by the high stress in the thermal oxide layer.
NASA Technical Reports Server (NTRS)
Radcliffe, Eliott (Inventor); Naguib, Ahmed (Inventor); Humphreys, Jr., William M. (Inventor)
2014-01-01
A feedback-controlled microphone includes a microphone body and a membrane operatively connected to the body. The membrane is configured to be initially deflected by acoustic pressure such that the initial deflection is characterized by a frequency response. The microphone also includes a sensor configured to detect the frequency response of the initial deflection and generate an output voltage indicative thereof. The microphone additionally includes a compensator in electric communication with the sensor and configured to establish a regulated voltage in response to the output voltage. Furthermore, the microphone includes an actuator in electric communication with the compensator, wherein the actuator is configured to secondarily deflect the membrane in opposition to the initial deflection such that the frequency response is adjusted. An acoustic beam forming microphone array including a plurality of the above feedback-controlled microphones is also disclosed.
Colletti, Vittorio; Mandalà, Marco; Manganotti, Paolo; Ramat, Stefano; Sacchetto, Luca; Colletti, Liliana
2011-07-01
The rapid spread of devices generating electromagnetic fields (EMF) has raised concerns as to the possible effects of this technology on humans. The auditory system is the neural organ most frequently and directly exposed to electromagnetic activity owing to the daily use of mobile phones. In recent publications, a possible correlation between mobile phone usage and central nervous system tumours has been detected. Very recently a deterioration in otoacoustic emissions and in the auditory middle latency responses after intensive and long-term magnetic field exposure in humans has been demonstrated. To determine with objective observations if exposure to mobile phone EMF affects acoustically evoked cochlear nerve compound action potentials, seven patients suffering from Ménière's disease and undergoing retrosigmoid vestibular neurectomy were exposed to the effects of mobile phone placed over the craniotomy for 5 min. All patients showed a substantial decrease in amplitude and a significant increase in latency of cochlear nerve compound action potentials during the 5 min of exposure to EMF. These changes lasted for a period of around 5 min after exposure. The possibility that EMF can produce relatively long-lasting effects on cochlear nerve conduction is discussed and analysed in light of contrasting previous literature obtained under non-surgical conditions. Limitations of this novel approach, including the effects of the anaesthetics, craniotomy and surgical procedure, are presented in detail.
Joly, Charles-Alexandre; Péan, Vincent; Hermann, Ruben; Seldran, Fabien; Thai-Van, Hung; Truy, Eric
2017-10-01
The cochlear implant (CI) fitting level prediction accuracy of electrically-evoked compound action potential (ECAP) should be enhanced by the addition of demographic data in models. No accurate automated fitting of CI based on ECAP has yet been proposed. We recorded ECAP in 45 adults who had been using MED-EL CIs for more than 11 months and collected the most comfortable loudness level (MCL) used for CI fitting (prog-MCL), perception thresholds (meas-THR), and MCL (meas-MCL) measured with the stimulation used for ECAP recording. Linear mixed models taking into account cochlear site factors were computed to explain prog-MCL, meas-MCL, and meas-THR. Cochlear region and ECAP threshold were predictors of the three levels. In addition, significant predictors were the ECAP amplitude for the prog-MCL and the duration of deafness for the prog-MCL and the meas-THR. Estimations were more accurate for the meas-THR, then the meas-MCL, and finally the prog-MCL. These results show that 1) ECAP thresholds are more closely related to perception threshold than to comfort level, 2) predictions are more accurate when the inter-subject and cochlear regions variations are considered, and 3) differences between the stimulations used for ECAP recording and for CI fitting make it difficult to accurately predict the prog-MCL from the ECAP recording. Predicted prog-MCL could be used as bases for fitting but should be used with care to avoid any uncomfortable or painful stimulation.
On the ability of consumer electronics microphones for environmental noise monitoring.
Van Renterghem, Timothy; Thomas, Pieter; Dominguez, Frederico; Dauwe, Samuel; Touhafi, Abdellah; Dhoedt, Bart; Botteldooren, Dick
2011-03-01
The massive production of microphones for consumer electronics, and the shift from dedicated processing hardware to PC-based systems, opens the way to build affordable, extensive noise measurement networks. Applications include e.g. noise limit and urban soundscape monitoring, and validation of calculated noise maps. Microphones are the critical components of such a network. Therefore, in a first step, some basic characteristics of 8 microphones, distributed over a wide range of price classes, were measured in a standardized way in an anechoic chamber. In a next step, a thorough evaluation was made of the ability of these microphones to be used for environmental noise monitoring. This was done during a continuous, half-year lasting outdoor experiment, characterized by a wide variety of meteorological conditions. While some microphones failed during the course of this test, it was shown that it is possible to identify cheap microphones that highly correlate to the reference microphone during the full test period. When the deviations are expressed in total A-weighted (road traffic) noise levels, values of less than 1 dBA are obtained, in excess to the deviation amongst reference microphones themselves.
Design and Evaluation of a Personal Digital Assistant-based Research Platform for Cochlear Implants
Ali, Hussnain; Lobo, Arthur P.; Loizou, Philipos C.
2014-01-01
This paper discusses the design, development, features, and clinical evaluation of a personal digital assistant (PDA)-based platform for cochlear implant research. This highly versatile and portable research platform allows researchers to design and perform complex experiments with cochlear implants manufactured by Cochlear Corporation with great ease and flexibility. The research platform includes a portable processor for implementing and evaluating novel speech processing algorithms, a stimulator unit which can be used for electrical stimulation and neurophysio-logic studies with animals, and a recording unit for collecting electroencephalogram/evoked potentials from human subjects. The design of the platform for real time and offline stimulation modes is discussed for electric-only and electric plus acoustic stimulation followed by results from an acute study with implant users for speech intelligibility in quiet and noisy conditions. The results are comparable with users’ clinical processor and very promising for undertaking chronic studies. PMID:23674422
Vestibulo-ocular and vestibulospinal function before and after cochlear implant surgery
NASA Technical Reports Server (NTRS)
Black, F. O.; Lilly, D. J.; Peterka, R. J.; Fowler, L. P.; Simmons, F. B.
1987-01-01
Vestibular function in cochlear implant candidates varies from normal to total absence of function. In patients with intact vestibular function preoperatively, invasion of the otic capsule places residual vestibular function at risk. Speech-processing strategies that result in large amplitude electrical transients or strategies that employ high amplitude broad frequency carrier signals have the potential for disrupting vestibular function. Five patients were tested with and without electrical stimulation via cochlear electrodes. Two patients experienced subjective vestibular effects that were quickly resolved. No long-term vestibular effects were noted for the two types of second generation cochlear implants evaluated. Histopathological findings from another patient, who had electrically generated vestibular reflex responses to intramodiolar electrodes, indicated that responses elicited were a function of several variables including electrode location, stimulus intensity, stimulus amplitude, and stimulus frequency. Differential auditory, vestibulocolic, and vestibulospinal reflexes were demonstrated from the same electrode as a function of stimulus amplitude, frequency, and duration.
Boyd, Paul J
2006-12-01
The principal task in the programming of a cochlear implant (CI) speech processor is the setting of the electrical dynamic range (output) for each electrode, to ensure that a comfortable loudness percept is obtained for a range of input levels. This typically involves separate psychophysical measurement of electrical threshold ([theta] e) and upper tolerance levels using short current bursts generated by the fitting software. Anecdotal clinical experience and some experimental studies suggest that the measurement of [theta]e is relatively unimportant and that the setting of upper tolerance limits is more critical for processor programming. The present study aims to test this hypothesis and examines in detail how acoustic thresholds and speech recognition are affected by setting of the lower limit of the output ("Programming threshold" or "PT") to understand better the influence of this parameter and how it interacts with certain other programming parameters. Test programs (maps) were generated with PT set to artificially high and low values and tested on users of the MED-EL COMBI 40+ CI system. Acoustic thresholds and speech recognition scores (sentence tests) were measured for each of the test maps. Acoustic thresholds were also measured using maps with a range of output compression functions ("maplaws"). In addition, subjective reports were recorded regarding the presence of "background threshold stimulation" which is occasionally reported by CI users if PT is set to relatively high values when using the CIS strategy. Manipulation of PT was found to have very little effect. Setting PT to minimum produced a mean 5 dB (S.D. = 6.25) increase in acoustic thresholds, relative to thresholds with PT set normally, and had no statistically significant effect on speech recognition scores on a sentence test. On the other hand, maplaw setting was found to have a significant effect on acoustic thresholds (raised as maplaw is made more linear), which provides some theoretical explanation as to why PT has little effect when using the default maplaw of c = 500. Subjective reports of background threshold stimulation showed that most users could perceive a relatively loud auditory percept, in the absence of microphone input, when PT was set to double the behaviorally measured electrical thresholds ([theta]e), but that this produced little intrusion when microphone input was present. The results of these investigations have direct clinical relevance, showing that setting of PT is indeed relatively unimportant in terms of speech discrimination, but that it is worth ensuring that PT is not set excessively high, as this can produce distracting background stimulation. Indeed, it may even be set to minimum values without deleterious effect.
Bergin, M J; Bird, P A; Vlajkovic, S M; Thorne, P R
2015-12-01
Permanent high frequency (>4 kHz) sensorineural hearing loss following middle ear surgery occurs in up to 25% of patients. The aetiology of this loss is poorly understood and may involve transmission of supra-physiological forces down the ossicular chain to the cochlea. Investigating the mechanisms of this injury using animal models is challenging, as evaluating cochlear function with evoked potentials is confounded when ossicular manipulation disrupts the normal air conduction (AC) pathway. Bone conduction (BC) using clinical bone vibrators in small animals is limited by poor transducer output at high frequencies sensitive to trauma. The objectives of the present study were firstly to evaluate a novel high frequency bone conduction transducer with evoked auditory potentials in a guinea pig model, and secondly to use this model to investigate the impact of middle ear surgical manipulation on cochlear function. We modified a magnetostrictive device as a high frequency BC transducer and evaluated its performance by comparison with a calibrated AC transducer at frequencies up to 32 kHz using the auditory brainstem response (ABR), compound action potential (CAP) and summating potential (SP). To mimic a middle ear traumatising stimulus, a rotating bur was brought in to contact with the incudomalleal complex and the effect on evoked cochlear potentials was observed. BC-evoked potentials followed the same input-output function pattern as AC potentials for all ABR frequencies. Deterioration in CAP and SP thresholds was observed after ossicular manipulation. It is possible to use high frequency BC to evoke responses from the injury sensitive basal region of the cochlea and so not rely on AC with the potential confounder of conductive hearing loss. Ongoing research explores how these findings evolve over time, and ways in which injury may be reduced and the cochlea protected during middle ear surgery. Copyright © 2015 Elsevier B.V. All rights reserved.
Music training improves pitch perception in prelingually deafened children with cochlear implants.
Chen, Joshua Kuang-Chao; Chuang, Ann Yi Chiun; McMahon, Catherine; Hsieh, Jen-Chuen; Tung, Tao-Hsin; Li, Lieber Po-Hung
2010-04-01
The comparatively poor music appreciation in patients with cochlear implants might be ascribed to an inadequate exposure to music; however, the effect of training on music perception in prelingually deafened children with cochlear implants remains unknown. This study aimed to investigate whether previous musical education improves pitch perception ability in these children. Twenty-seven children with congenital/prelingual deafness of profound degree were studied. Test stimuli consisted of 2 sequential piano tones, ranging from C (256 Hz) to B (495 Hz). Children were asked to identify the pitch relationship between the 2 tones (same, higher, or lower). Effects of musical training duration, pitch-interval size, current age, age of implantation, gender, and type of cochlear implant on accuracy of pitch perception were evaluated. The duration of musical training positively correlated with the correct rate of pitch perception. Pitch perception performance was better in children who had a cochlear implant and were older than 6 years than in those who were aged < or =6 years (ie, preschool). Effect of pitch-interval size was insignificant on pitch perception, and there was no correlation between pitch perception and the age of implantation, gender, or type of cochlear implant. Musical training seems to improve pitch perception ability in prelingually deafened children with a cochlear implant. Auditory plasticity might play an important role in such enhancement. This suggests that incorporation of a structured training program on music perception early in life and as part of the postoperative rehabilitation program for prelingually deafened children with cochlear implants would be beneficial. A longitudinal study is needed to show whether improvement of music performance in these children is measurable by use of auditory evoked potentials.
Optimization of Acoustic Pressure Measurements for Impedance Eduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.; Nark, D. M.
2007-01-01
As noise constraints become increasingly stringent, there is continued emphasis on the development of improved acoustic liner concepts to reduce the amount of fan noise radiated to communities surrounding airports. As a result, multiple analytical prediction tools and experimental rigs have been developed by industry and academia to support liner evaluation. NASA Langley has also placed considerable effort in this area over the last three decades. More recently, a finite element code (Q3D) based on a quasi-3D implementation of the convected Helmholtz equation has been combined with measured data acquired in the Langley Grazing Incidence Tube (GIT) to reduce liner impedance in the presence of grazing flow. A new Curved Duct Test Rig (CDTR) has also been developed to allow evaluation of liners in the presence of grazing flow and controlled, higher-order modes, with straight and curved waveguides. Upgraded versions of each of these two test rigs are expected to begin operation by early 2008. The Grazing Flow Impedance Tube (GFIT) will replace the GIT, and additional capabilities will be incorporated into the CDTR. The current investigation uses the Q3D finite element code to evaluate some of the key capabilities of these two test rigs. First, the Q3D code is used to evaluate the microphone distribution designed for the GFIT. Liners ranging in length from 51 to 610 mm are investigated to determine whether acceptable impedance eduction can be achieved with microphones placed on the wall opposite the liner. This analysis indicates the best results are achieved for liner lengths of at least 203 mm. Next, the effects of moving this GFIT microphone array to the wall adjacent to the liner are evaluated, and acceptable results are achieved if the microphones are placed off the centerline. Finally, the code is used to investigate potential microphone placements in the CDTR rigid wall adjacent to the wall containing an acoustic liner, to determine if sufficient fidelity can be achieved with 32 microphones available for this purpose. Initial results indicate 32 microphones can provide acceptable measurements to support impedance eduction with this test rig.
Heeringa, Amarins N.; Stefanescu, Roxana A.; Raphael, Yehoash; Shore, Susan E.
2015-01-01
Vesicular glutamate transporters 1 and 2 (VGLUT1 and VGLUT2) have distinct distributions in the cochlear nucleus that correspond to the sources of the labeled terminals. VGLUT1 is mainly associated with terminals of auditory nerve fibers, whereas VGLUT2 is mainly associated with glutamatergic terminals deriving from other sources that project to the cochlear nucleus (CN), including somatosensory and vestibular terminals. Previous studies in guinea pig have shown that cochlear damage results in a decrease of VGLUT1-labeled puncta and an increase in VGLUT2-labeled puncta. This indicates cross-modal compensation that is of potential importance in somatic tinnitus. To examine whether this effect is consistent across species and to provide a background for future studies, using transgenesis, the current study examines VGLUT expression profiles upon cochlear insult by intracochlear kanamycin injections in the mouse. Intracochlear kanamycin injections abolished ipsilateral ABR responses in all animals and reduced ipsilateral spiral ganglion neuron densities in animals that were sacrificed after four weeks, but not in animals that were sacrificed after three weeks. In all unilaterally deafened animals, VGLUT1 density was decreased in CN regions that receive auditory nerve fiber terminals, i.e. in the deep layer of the dorsal cochlear nucleus (DCN), in the interstitial region where the auditory nerve enters the CN, and in the magnocellular region of the antero- and posteroventral CN. In contrast, density of VGLUT2 expression was upregulated in the fusiform cell layer of the DCN and in the granule cell lamina, which are known to receive somatosensory and vestibular terminals. These results show that a cochlear insult induces cross-modal compensation in the cochlear nucleus of the mouse, confirming previous findings in guinea pig, and that these changes are not dependent on the occurrence of spiral ganglion neuron degeneration. PMID:26705736
Heeringa, A N; Stefanescu, R A; Raphael, Y; Shore, S E
2016-02-19
Vesicular glutamate transporters 1 and 2 (VGLUT1 and VGLUT2) have distinct distributions in the cochlear nucleus that correspond to sources of the labeled terminals. VGLUT1 is mainly associated with terminals of auditory nerve fibers, whereas VGLUT2 is mainly associated with glutamatergic terminals deriving from other sources that project to the cochlear nucleus (CN), including somatosensory and vestibular terminals. Previous studies in guinea pig have shown that cochlear damage results in a decrease of VGLUT1-labeled puncta and an increase in VGLUT2-labeled puncta. This indicates cross-modal compensation that is of potential importance in somatic tinnitus. To examine whether this effect is consistent across species and to provide a background for future studies, using transgenesis, the current study examines VGLUT expression profiles upon cochlear insult by intracochlear kanamycin injections in the mouse. Intracochlear kanamycin injections abolished ipsilateral ABR responses in all animals and reduced ipsilateral spiral ganglion neuron densities in animals that were sacrificed after four weeks, but not in animals that were sacrificed after three weeks. In all unilaterally deafened animals, VGLUT1 density was decreased in CN regions that receive auditory nerve fiber terminals, i.e., in the deep layer of the dorsal cochlear nucleus (DCN), in the interstitial region where the auditory nerve enters the CN, and in the magnocellular region of the antero- and posteroventral CN. In contrast, density of VGLUT2 expression was upregulated in the fusiform cell layer of the DCN and in the granule cell lamina, which are known to receive somatosensory and vestibular terminals. These results show that a cochlear insult induces cross-modal compensation in the cochlear nucleus of the mouse, confirming previous findings in guinea pig, and that these changes are not dependent on the occurrence of spiral ganglion neuron degeneration. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.
Should children who use cochlear implants wear hearing aids in the opposite ear?
Ching, T Y; Psarros, C; Hill, M; Dillon, H; Incerti, P
2001-10-01
The aim of this study was to investigate 1) whether a hearing aid needs to be adjusted differently depending on whether a child wears a cochlear implant or another hearing aid in the contralateral ear; 2) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural interference; and 3) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural benefits in speech perception, localization, and communicative functioning in real life. Sixteen children participated in this study. All children used a Nucleus 22 or Nucleus 24 cochlear implant system programmed with the SPEAK strategy in one ear. The hearing aid amplification requirements in the nonimplanted ear of these children were determined using two procedures. A paired comparison technique was used to identify the frequency response that was best for speech intelligibility in quiet, and a loudness balancing technique was used to match the loudness of speech in the ear with a hearing aid to that with a cochlear implant. Eleven of the 16 children participated in the investigation of binaural effects. Performance in speech perception, localization, and communicative functioning was assessed under four aided conditions: cochlear implant with hearing aid as worn, cochlear implant alone, hearing aid alone, and cochlear implant with hearing aid adjusted according to individual requirements. Fifteen of the 16 children whose amplification requirements were determined preferred a hearing aid frequency response that was within +/-6 dB/octave of the NAL-RP prescription. On average, the children required 6 dB more gain than prescribed to balance the loudness of the implanted ear for a speech signal presented at 65 dB SPL. For all 11 children whose performance was evaluated for investigating binaural effects, there was no indication of significantly poorer performance under bilaterally aided conditions compared with unilaterally aided conditions. On average, there were significant benefits in speech perception, localization, and aural/oral function when the children used cochlear implants with adjusted hearing aids than when they used cochlear implants alone. All individuals showed benefits in at least one of the measures. Hearing aids for children who also use cochlear implants can be selected using the NAL-RP prescription. Adjustment of hearing aid gain to match loudness in the implanted ear can facilitate integration of signals from both ears, leading to better speech perception. Given that there are binaural advantages from using cochlear implants with hearing aids in opposite ears, clinicians should advise parents and other professionals about these potential advantages, and facilitate bilateral amplification by adjusting hearing aids after stable cochlear implant MAPs are established.
Winn, Matthew B; Won, Jong Ho; Moon, Il Joon
This study was conducted to measure auditory perception by cochlear implant users in the spectral and temporal domains, using tests of either categorization (using speech-based cues) or discrimination (using conventional psychoacoustic tests). The authors hypothesized that traditional nonlinguistic tests assessing spectral and temporal auditory resolution would correspond to speech-based measures assessing specific aspects of phonetic categorization assumed to depend on spectral and temporal auditory resolution. The authors further hypothesized that speech-based categorization performance would ultimately be a superior predictor of speech recognition performance, because of the fundamental nature of speech recognition as categorization. Nineteen cochlear implant listeners and 10 listeners with normal hearing participated in a suite of tasks that included spectral ripple discrimination, temporal modulation detection, and syllable categorization, which was split into a spectral cue-based task (targeting the /ba/-/da/ contrast) and a timing cue-based task (targeting the /b/-/p/ and /d/-/t/ contrasts). Speech sounds were manipulated to contain specific spectral or temporal modulations (formant transitions or voice onset time, respectively) that could be categorized. Categorization responses were quantified using logistic regression to assess perceptual sensitivity to acoustic phonetic cues. Word recognition testing was also conducted for cochlear implant listeners. Cochlear implant users were generally less successful at utilizing both spectral and temporal cues for categorization compared with listeners with normal hearing. For the cochlear implant listener group, spectral ripple discrimination was significantly correlated with the categorization of formant transitions; both were correlated with better word recognition. Temporal modulation detection using 100- and 10-Hz-modulated noise was not correlated either with the cochlear implant subjects' categorization of voice onset time or with word recognition. Word recognition was correlated more closely with categorization of the controlled speech cues than with performance on the psychophysical discrimination tasks. When evaluating people with cochlear implants, controlled speech-based stimuli are feasible to use in tests of auditory cue categorization, to complement traditional measures of auditory discrimination. Stimuli based on specific speech cues correspond to counterpart nonlinguistic measures of discrimination, but potentially show better correspondence with speech perception more generally. The ubiquity of the spectral (formant transition) and temporal (voice onset time) stimulus dimensions across languages highlights the potential to use this testing approach even in cases where English is not the native language.
NASA Technical Reports Server (NTRS)
Pickett, G. F.; Wells, R. A.; Love, R. A.
1977-01-01
A computer user's manual describing the operation and the essential features of the microphone location program is presented. The Microphone Location Program determines microphone locations that ensure accurate and stable results from the equation system used to calculate modal structures. As part of the computational procedure for the Microphone Location Program, a first-order measure of the stability of the equation system was indicated by a matrix 'conditioning' number.
Ruscetta, Melissa N; Palmer, Catherine V; Durrant, John D; Grayhack, Judith; Ryan, Carey
2007-10-01
The chief complaint of individuals with hearing impairment is difficulty hearing in noise, with directional microphones emerging as the most capable remediation. Our purpose was to determine the impact of directional microphones on localization disability and concurrent handicap. Fifty-seven individuals participated unaided and then in groups of 19, using omni-directional microphones, directional-microphones, or toggle-switch equipped amplification. The outcome measure was a localization disabilities and handicaps questionnaire. Comparisons between the unaided group versus the aided groups, and the directional-microphone groups versus the other two aided groups revealed no significant differences. None of the microphone schemes either increased or decreased self-perceived localization disability or handicap. Objective measures of localization ability are warranted and if significance is noted, clinicians should caution patients when moving in their environment. If no significant objective differences exist, in light of the subjective findings in this investigation concern over decreases in quality of life and safety with directional microphones need not be considered.
Practical considerations for a second-order directional hearing aid microphone system
NASA Astrophysics Data System (ADS)
Thompson, Stephen C.
2003-04-01
First-order directional microphone systems for hearing aids have been available for several years. Such a system uses two microphones and has a theoretical maximum free-field directivity index (DI) of 6.0 dB. A second-order microphone system using three microphones could provide a theoretical increase in free-field DI to 9.5 dB. These theoretical maximum DI values assume that the microphones have exactly matched sensitivities at all frequencies of interest. In practice, the individual microphones in the hearing aid always have slightly different sensitivities. For the small microphone separation necessary to fit in a hearing aid, these sensitivity matching errors degrade the directivity from the theoretical values, especially at low frequencies. This paper shows that, for first-order systems the directivity degradation due to sensitivity errors is relatively small. However, for second-order systems with practical microphone sensitivity matching specifications, the directivity degradation below 1 kHz is not tolerable. A hybrid order directive system is proposed that uses first-order processing at low frequencies and second-order directive processing at higher frequencies. This hybrid system is suggested as an alternative that could provide improved directivity index in the frequency regions that are important to speech intelligibility.
Wagner, Randall P.; Guthrie, William F.
2015-01-01
The devices calibrated most frequently by the acoustical measurement services at the National Institute of Standards and Technology (NIST) over the 50-year period from 1963 to 20121 were one-inch condenser microphones of three specific standard types: LS1Pn, LS1Po, and WS1P. Due to its long history of providing calibrations of such microphones to customers, NIST is in a unique position to analyze data concerning the long-term stability of these devices. This long history has enabled NIST to acquire and aggregate a substantial amount of repeat calibration data for a large number of microphones that belong to various other standards and calibration laboratories. In addition to determining microphone sensitivities at the time of calibration, it is important to have confidence that the microphones do not typically undergo significant drift as compared to the calibration uncertainty during the periods between calibrations. For each of the three microphone types, an average drift rate and approximate 95 % confidence interval were computed by two different statistical methods, and the results from the two methods were found to differ insignificantly in each case. These results apply to typical microphones of these types that are used in a suitable environment and handled with care. The average drift rate for Type LS1Pn microphones was −0.004 dB/year to 0.003 dB/year. The average drift rate for Type LS1Po microphones was −0.016 dB/year to 0.008 dB/year. The average drift rate for Type WS1P microphones was −0.004 dB/year to 0.018 dB/year. For each of these microphone types, the average drift rate is not significantly different from zero. This result is consistent with the performance expected of condenser microphones designed for use as transfer standards. In addition, the values that bound the confidence intervals are well within the limits specified for long-term stability in international standards. Even though these results show very good long-term stability historically for these microphone types, it is expected that periodic calibrations will always be done to track the calibration history of individual microphones and check for anomalies indicative of shifts in sensitivity. PMID:26958445
Hossain, Waheeda A; Antic, Srdjan D; Yang, Yang; Rasband, Matthew N; Morest, D Kent
2005-07-20
The origin of the action potential in the cochlea has been a long-standing puzzle. Because voltage-dependent Na+ (Nav) channels are essential for action potential generation, we investigated the detailed distribution of Nav1.6 and Nav1.2 in the cochlear ganglion, cochlear nerve, and organ of Corti, including the type I and type II ganglion cells. In most type I ganglion cells, Nav1.6 was present at the first nodes flanking the myelinated bipolar cell body and at subsequent nodes of Ranvier. In the other ganglion cells, including type II, Nav1.6 clustered in the initial segments of both of the axons that flank the unmyelinated bipolar ganglion cell bodies. In the organ of Corti, Nav1.6 was localized in the short segments of the afferent axons and their sensory endings beneath each inner hair cell. Surprisingly, the outer spiral fibers and their sensory endings were well labeled beneath the outer hair cells over their entire trajectory. In contrast, Nav1.2 in the organ of Corti was localized to the unmyelinated efferent axons and their endings on the inner and outer hair cells. We present a computational model illustrating the potential role of the Nav channel distribution described here. In the deaf mutant quivering mouse, the localization of Nav1.6 was disrupted in the sensory epithelium and ganglion. Together, these results suggest that distinct Nav channels generate and regenerate action potentials at multiple sites along the cochlear ganglion cells and nerve fibers, including the afferent endings, ganglionic initial segments, and nodes of Ranvier.
Hidden Hearing Injury: The Emerging Science and Military Relevance of Cochlear Synaptopathy.
Tepe, Victoria; Smalt, Christopher; Nelson, Jeremy; Quatieri, Thomas; Pitts, Kenneth
2017-09-01
The phenomenon recently described as "hidden hearing loss" was the subject of a meeting co-hosted by the Department of Defense Hearing Center of Excellence and MIT Lincoln Laboratory to consider the potential relevance of noise-related synaptopathic injury to military settings and performance, service-related injury scenarios, and military medical priorities. Participants included approximately 50 researchers and subject matter experts from academic, federal, and military laboratories. Here we present a synthesis of discussion topics and concerns, as well as specific research objectives identified to develop militarily relevant knowledge. We consider findings from studies to date that have demonstrated cochlear synaptopathy and neurodegenerative processes apparently linked to noise exposure in animal models. We explore the potential relevance of these findings to the prediction and prevention of military hearing injuries, and to comorbid injuries in the neurological domain. Noise-induced cochlear synaptopathic injury is not detected by conventional audiometric assessment of threshold sensitivity. Animal studies suggest there may be a generous window of opportunity for intervention to mitigate or prevent cochlear neurodegenerative processes, e.g., by administration of neurotrophins or antioxidants. However, it is not yet known if the mechanisms that underlie "hidden hearing loss" also occur in human beings or, if so, how to identify them early, and how and when to intervene. Neurological injuries resulting from noise exposures via the auditory system have potentially significant implications for military Service Member performance, long-term Veteran health, and noise exposure standards. Mediated via auditory pathways, such injuries have possible relationship to clinical impairments including speech perception, and may be a largely overlooked contributor to cognitive symptoms associated with other military service-related injuries such as blast exposure and brain trauma. The potential health and performance consequences of noise-induced cochlear synaptopathic injury are easily overlooked, especially if it is assumed that hearing threshold sensitivity loss is the major concern. There should be a renewed impetus to further characterize and model synaptopathic mechanisms of auditory injury; study its potential impact on human auditory function, cognition, and performance metrics of military relevance; and develop solutions for auditory protection (including noise dosimetry) and treatment if appropriate following noise or blast exposure in military scenarios. We identify specific problems, solution objectives, and research objectives. Recommended research calls for a multidisciplinary approach to address cochlear nerve synaptopathy, central (brain) dysfunction, noise exposure measurement and metrics, and clinical assessment. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Intracellular studies of hair cells in the mammalian cochlea.
Russell, I J; Sellick, P M
1978-01-01
1. Intracellular recordings were made from inner hair cells in the first turn of the guinea-pig cochlea, the recording sites being confirmed by the injection of Procion yellow dye and subsequent histology. 2. The receptor potential, in response to a pure tone burst, consisted of an AC response which followed the wave form of the stimulus and was analogous to the extracellularly recorded cochlear microphonic and a depolarizating DC response which followed the envelope of the tone burst and was analogous to the extracellularly recorded summating potential. 3. The DC response was broadly tuned at high sound pressure having a maximal amplitude of 27 mV at a sound pressure level of ca. 100 db; however the bandwidth of the response was reduced at lower sound pressure level. Isoamplitude curves for the DC response were indistinguishable from the threshold curves for auditory nerve fibres. 4. The AC response was tuned in a similar fashion to the DC response except that it was attenuated at 6-9 db/octave with respect to the DC response. It is suggested that this difference was due to the effect of membrane capacitance and resistance on the AC response. In contrast the extracellularly recorded AC component was not subject to this attenuation. 5. The total resistance and capacitance in three cells were found to be 46-61 Momega and 7.8-15.8 muF respectively. 6. Intracellular resistance changes were measured during sound stimulation, the resistance change being proportional to the DC receptor potential, indicating constant current flow through the hair cell. The current varied between 0.37 and 0.81 nA between cells. The time constant for seven cells was found to lie between 0.31 and 0.76 msec. 7. A map of the basilar membrane showing position of hair cells against characteristic frequency corresponded to the cut-off frequencies of the basilar membrane mechanical measurements and the innervation sites of spiral ganglion cells. PMID:731538
Wu, T; Dai, M; Shi, X R; Jiang, Z G; Nuttall, A L
2011-07-01
The cochlear lateral wall generates the endocochlear potential (EP), which creates a driving force for the hair cell transduction current and is essential for normal hearing. Blood flow at the cochlear lateral wall is critically important for maintaining the EP. The vulnerability of the EP to hypoxia suggests that the blood flow in the cochlear lateral wall is dynamically and precisely regulated to meet the changing metabolic needs of the cochlear lateral wall. It has been reported that ATP, an important extracellular signaling molecule, plays an essential role in regulating cochlear blood flow. However, the cellular mechanism underlying ATP-induced regional blood flow changes has not been investigated. In the current study, we demonstrate that 1) the P2X4 receptor is expressed in endothelial cells (ECs) of spiral ligament (SL) capillaries. 2) ATP elicits a characteristic current through P2X4 on ECs in a dose-dependent manner (EC(50) = 0.16 mM). The ATP current has a reversal potential at ∼0 mV; is inhibited by 5-(3-bromophenyl)-1,3-dihydro-2H-benzofuro[3,2-e]-1,4-diazepin-2-one (5-BDBD), LaCl(3), pyridoxal phosphate-6-azo(benzene-2,4-disulfonic acid) tetrasodium salt hydrate (PPADS), and extracellular acidosis; and is less sensitive to α,β-methyleneadenosine 5'-triphosphate (α,β-MeATP) and 2'- and 3'-O-(4-benzoyl-benzoyl) adenosine 5'-triphosphate (BzATP). 3) ATP elicits a transient increase of intracellular Ca(2+) in ECs. 4) In accordance with the above in vitro findings, perilymphatic ATP (1 mM) caused dilation in SL capillaries in vivo by 11.5%. N(ω)-nitro-l-arginine methyl ester hydrochloride (l-NAME), a nonselective inhibitor of nitric oxide synthase, or 5-BDBD, the specific P2X4 inhibitor, significantly blocked the dilation. These findings support our hypothesis that extracellular ATP regulates cochlear lateral blood flow through P2X4 activation in ECs.
Musical experience sharpens human cochlear tuning.
Bidelman, Gavin M; Nelms, Caitlin; Bhagat, Shaum P
2016-05-01
The mammalian cochlea functions as a filter bank that performs a spectral, Fourier-like decomposition on the acoustic signal. While tuning can be compromised (e.g., broadened with hearing impairment), whether or not human cochlear frequency resolution can be sharpened through experiential factors (e.g., training or learning) has not yet been established. Previous studies have demonstrated sharper psychophysical tuning curves in trained musicians compared to nonmusicians, implying superior peripheral tuning. However, these findings are based on perceptual masking paradigms, and reflect engagement of the entire auditory system rather than cochlear tuning, per se. Here, by directly mapping physiological tuning curves from stimulus frequency otoacoustic emissions (SFOAEs)-cochlear emitted sounds-we show that estimates of human cochlear tuning in a high-frequency cochlear region (4 kHz) is further sharpened (by a factor of 1.5×) in musicians and improves with the number of years of their auditory training. These findings were corroborated by measurements of psychophysical tuning curves (PTCs) derived via simultaneous masking, which similarly showed sharper tuning in musicians. Comparisons between SFOAE and PTCs revealed closer correspondence between physiological and behavioral curves in musicians, indicating that tuning is also more consistent between different levels of auditory processing in trained ears. Our findings demonstrate an experience-dependent enhancement in the resolving power of the cochlear sensory epithelium and the spectral resolution of human hearing and provide a peripheral account for the auditory perceptual benefits observed in musicians. Both local and feedback (e.g., medial olivocochlear efferent) mechanisms are discussed as potential mechanisms for experience-dependent tuning. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Shuzhi; Cai, Qunfeng; Bard, Jonathan; Jamison, Jennifer; Wang, Jianmin; Yang, Weiping; Hu, Bo Hua
2015-12-01
Individual variation in the susceptibility of the auditory system to acoustic overstimulation has been well-documented at both the functional and structural levels. However, the molecular mechanism responsible for this variation is unclear. The current investigation was designed to examine the variation patterns of cochlear gene expression using RNA-seq data and to identify the genes with expression variation that increased following acoustic trauma. This study revealed that the constitutive expressions of cochlear genes displayed diverse levels of gene-specific variation. These variation patterns were altered by acoustic trauma; approximately one-third of the examined genes displayed marked increases in their expression variation. Bioinformatics analyses revealed that the genes that exhibited increased variation were functionally related to cell death, biomolecule metabolism, and membrane function. In contrast, the stable genes were primarily related to basic cellular processes, including protein and macromolecular syntheses and transport. There was no functional overlap between the stable and variable genes. Importantly, we demonstrated that glutamate metabolism is related to the variation in the functional response of the cochlea to acoustic overstimulation. Taken together, the results indicate that our analyses of the individual variations in transcriptome changes of cochlear genes provide important information for the identification of genes that potentially contribute to the generation of individual variation in cochlear responses to acoustic overstimulation. Copyright © 2015 Elsevier B.V. All rights reserved.
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and post-implant language development and executive function. Method Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (FES) and an inventory of executive function (BRIEF/BRIEF-P). Children’s receptive vocabulary (PPVT-4) and global language skills (PLS-4/CELF-4) were also evaluated. Results The family environments of children with cochlear implants differed from those of normal-hearing children, but not in clinically significant ways. Language development and executive function were found to be atypical, but not uncharacteristic of this clinical population. Families with higher levels of self-reported control had children with smaller vocabularies. Families reporting a higher emphasis on achievement had children with fewer executive function and working memory problems. Finally, families reporting a higher emphasis on organization had children with fewer problems related to inhibition. Conclusions Some of the variability in cochlear implantation outcomes that have protracted periods of development is related to family environment. Because family environment can be modified and enhanced by therapy or education, these preliminary findings hold promise for future work in helping families to create robust language-learning environments that can maximize their child’s potential with a cochlear implant. PMID:22232387
Questioning cochlear amplification
NASA Astrophysics Data System (ADS)
van der Heijden, Marcel; Versteegh, Corstiaen P. C.
2015-12-01
Thirty years ago it was hypothesized that motile processes inject mechanical energy into cochlear traveling waves. This mechanical amplification, alternatively described as negative damping, is invoked to explain both the sensitivity and the nonlinear compression of cochlear responses. There is a recent trend to present cochlear amplification as an established fact, even though the evidence is at most circumstantial and several thorny problems have remained unresolved. We analyze several of these issues, and present new basilar membrane recordings that allowed us to quantify cochlear energy flow. Specifically, we address the following questions: (1) Does auditory sensitivity require narrowband amplification? (2) Has the "RC problem" (lowpass filtering of outer hair cell receptor potential) been resolved? (3) Can OHC motility improve auditory sensitivity? (4) Is there a net power gain between neighboring locations on the basilar membrane? The analyses indicate that mechanical amplification in the cochlea is neither necessary nor useful, and that realizing it by known forms of motility would reduce sensitivity rather than enhance it. Finally, our experimental data show that the peaking of the traveling wave is realized by focusing the acoustic energy rather than amplifying it. (Abbreviations. BM: basilar membrane; CF: characteristic frequency; IHC: inner hair cell; ME: middle ear; MT; mechanotransducer; OHC: outer hair cell; SPL: sound pressure level.)
Evidence-based guidelines for recommending cochlear implantation for postlingually deafened adults.
Leigh, Jaime R; Moran, Michelle; Hollow, Rodney; Dowell, Richard C
2016-01-01
Adult selection criteria for cochlear implantation have been developed based on analysis of the post-operative performance of a large group of postlingually deafened adults. Original criteria published in 2004 were reviewed and amended to reflect outcomes currently being achieved by implant recipients. Retrospective review of 12-month post-operative speech perception performance of adults implanted at the Eye and Ear Hospital, Melbourne, Australia. A total of 382 postlingually deafened adults, using a Freedom, Nucleus 5, or CI422 Slim Straight cochlear implant were used to create a comparative set of data. Revised guidelines suggest that adults with postlingual hearing loss can now be considered cochlear implant candidates if they obtain scores of up to 55% for open-set phonemes in quiet in the ear to be implanted. Functional benefit may vary depending on the recipients' contralateral hearing. This study supports the provision of cochlear implants to candidates with significant residual hearing when at least one ear meets the criterion outlined above. Patient-specific counseling is required to ensure the potential to benefit predicted by the current model is acceptable to the individual patient and their family. Counseling regarding functional benefit must take into consideration hearing in the contralateral ear.
Chronic lead exposure induces cochlear oxidative stress and potentiates noise-induced hearing loss.
Jamesdaniel, Samson; Rosati, Rita; Westrick, Judy; Ruden, Douglas M
2018-08-01
Acquired hearing loss is caused by complex interactions of multiple environmental risk factors, such as elevated levels of lead and noise, which are prevalent in urban communities. This study delineates the mechanism underlying lead-induced auditory dysfunction and its potential interaction with noise exposure. Young-adult C57BL/6 mice were exposed to: 1) control conditions; 2) 2 mM lead acetate in drinking water for 28 days; 3) 90 dB broadband noise 2 h/day for two weeks; and 4) both lead and noise. Blood lead levels were measured by inductively coupled plasma mass spectrometry analysis (ICP-MS) lead-induced cochlear oxidative stress signaling was assessed using targeted gene arrays, and the hearing thresholds were assessed by recording auditory brainstem responses. Chronic lead exposure downregulated cochlear Sod1, Gpx1, and Gstk1, which encode critical antioxidant enzymes, and upregulated ApoE, Hspa1a, Ercc2, Prnp, Ccl5, and Sqstm1, which are indicative of cellular apoptosis. Isolated exposure to lead or noise induced 8-12 dB and 11-25 dB shifts in hearing thresholds, respectively. Combined exposure induced 18-30 dB shifts, which was significantly higher than that observed with isolated exposures. This study suggests that chronic exposure to lead induces cochlear oxidative stress and potentiates noise-induced hearing impairment, possibly through parallel pathways. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Adenosine and the Auditory System
Vlajkovic, Srdjan M; Housley, Gary D; Thorne, Peter R
2009-01-01
Adenosine is a signalling molecule that modulates cellular activity in the central nervous system and peripheral organs via four G protein-coupled receptors designated A1, A2A, A2B, and A3. This review surveys the literature on the role of adenosine in auditory function, particularly cochlear function and its protection from oxidative stress. The specific tissue distribution of adenosine receptors in the mammalian cochlea implicates adenosine signalling in sensory transduction and auditory neurotransmission although functional studies have demonstrated that adenosine stimulates cochlear blood flow, but does not alter the resting and sound-evoked auditory potentials. An interest in a potential otoprotective role for adenosine has recently evolved, fuelled by the capacity of A1 adenosine receptors to prevent cochlear injury caused by acoustic trauma and ototoxic drugs. The balance between A1 and A2A receptors is conceived as critical for cochlear response to oxidative stress, which is an underlying mechanism of the most common inner ear pathologies (e.g. noise-induced and age-related hearing loss, drug ototoxicity). Enzymes involved in adenosine metabolism, adenosine kinase and adenosine deaminase, are also emerging as attractive targets for controlling oxidative stress in the cochlea. Other possible targets include ectonucleotidases that generate adenosine from extracellular ATP, and nucleoside transporters, which regulate adenosine concentrations on both sides of the plasma membrane. Developments of selective adenosine receptor agonists and antagonists that can cross the blood-cochlea barrier are bolstering efforts to develop therapeutic interventions aimed at ameliorating cochlear injury. Manipulations of the adenosine signalling system thus hold significant promise in the therapeutic management of oxidative stress in the cochlea. PMID:20190966
Mulders, W.H.A.M.; Ding, D.; Salvi, R.; Robertson, D.
2011-01-01
Acoustic trauma caused by exposure to a very loud sound increases spontaneous activity in central auditory structures such as the inferior colliculus. This hyperactivity has been suggested as a neural substrate for tinnitus, a phantom hearing sensation. In previous studies we have described a tentative link between the frequency region of hearing impairment and the corresponding tonotopic regions in the inferior colliculus showing hyperactivity. In this study we further investigated the relationship between cochlear compound action potential threshold loss, cochlear outer and inner hair cell loss and central hyperactivity in inferior colliculus of guinea pigs. Two weeks after a 10 kHz pure tone acoustic trauma, a tight relationship was demonstrated between the frequency region of compound action potential threshold loss and frequency regions in the inferior colliculus showing hyperactivity. Extending the duration of the acoustic trauma from 1 to 2 h did not result in significant increases in final cochlear threshold loss, but did result in a further increase of spontaneous firing rates in the inferior colliculus. Interestingly, hair cell loss was not present in the frequency regions where elevated cochlear thresholds and central hyperactivity were measured, suggesting that subtle changes in hair cell or primary afferent neural function are sufficient for central hyperactivity to be triggered and maintained. PMID:21491427
Response Identification in the Extremely Low Frequency Region of an Electret Condenser Microphone
Jeng, Yih-Nen; Yang, Tzung-Ming; Lee, Shang-Yin
2011-01-01
This study shows that a small electret condenser microphone connected to a notebook or a personal computer (PC) has a prominent response in the extremely low frequency region in a specific environment. It confines most acoustic waves within a tiny air cell as follows. The air cell is constructed by drilling a small hole in a digital versatile disk (DVD) plate. A small speaker and an electret condenser microphone are attached to the two sides of the hole. Thus, the acoustic energy emitted by the speaker and reaching the microphone is strong enough to actuate the diaphragm of the latter. The experiments showed that, once small air leakages are allowed on the margin of the speaker, the microphone captured the signal in the range of 0.5 to 20 Hz. Moreover, by removing the plastic cover of the microphone and attaching the microphone head to the vibration surface, the low frequency signal can be effectively captured too. Two examples are included to show the convenience of applying the microphone to pick up the low frequency vibration information of practical systems. PMID:22346594
Response identification in the extremely low frequency region of an electret condenser microphone.
Jeng, Yih-Nen; Yang, Tzung-Ming; Lee, Shang-Yin
2011-01-01
This study shows that a small electret condenser microphone connected to a notebook or a personal computer (PC) has a prominent response in the extremely low frequency region in a specific environment. It confines most acoustic waves within a tiny air cell as follows. The air cell is constructed by drilling a small hole in a digital versatile disk (DVD) plate. A small speaker and an electret condenser microphone are attached to the two sides of the hole. Thus, the acoustic energy emitted by the speaker and reaching the microphone is strong enough to actuate the diaphragm of the latter. The experiments showed that, once small air leakages are allowed on the margin of the speaker, the microphone captured the signal in the range of 0.5 to 20 Hz. Moreover, by removing the plastic cover of the microphone and attaching the microphone head to the vibration surface, the low frequency signal can be effectively captured too. Two examples are included to show the convenience of applying the microphone to pick up the low frequency vibration information of practical systems.
[An implantable microphone for electronic hearing aids].
Leysieffer, H; Müller, G; Zenner, H P
1997-10-01
Fully implantable hearing aids and cochlea implants of the future require an implantable microphone. A hermetically sealed implantable microphone based on the idea of a microphone implanted in the posterior wall of the auditory canal, as suggested by Ohno et al. in 1988, is presented. Through consistent technological and clinical design optimization, it was possible to achieve a membrane diameter of only 4.5 mm (as opposed to 8 mm in the Japanese system) and a significant volume reduction of nearly 50%. The microphone weights only 0.4 g. In spite of this miniaturization, the performance characteristics of the microphone equal those of the Japanese model or are superior. The sound-pressure transfer function shows a very small ripple and the bandwidth amounts to approximately 10 kHz. Because of its high tuning and high no-load resonance frequency, the microphone is mostly insensitive to post-operational changes to the loading mass on the microphone membrane initiated by the covering skin of the auditory canal. The sound-pressure transfer factor at 1000 Hz is approximately 1.5 mV/Pa. Using different manufacturing technologies, this value can be increased in the range of 6-8 dB with a corresponding reduction in bandwidth. Due to the small mass, the microphone is highly insensitive to environmental mechanical disturbances. The module is made of pure titanium and is hermetically sealed according to Mil-Std 883 D. Full metal encapsulation and additional internal electronic components protect the microphone well against environmental electromagnetic influences (EMC).
NASA Astrophysics Data System (ADS)
Ganji, Bahram Azizollah; Sedaghat, Sedighe Babaei; Roncaglia, Alberto; Belsito, Luca; Ansari, Reza
2018-01-01
This paper presents design, modeling, and fabrication of a crab-shape microphone using silicon-on-isolator (SOI) wafer. SOI wafer is used to prevent the additional deposition of sacrificial and diaphragm layers. The holes have been made on diaphragm to prevent back plate etching. Dry etching is used for removing the sacrificial layer, because wet etching causes adhesion between the diaphragm and the back plate. Crab legs around the perforated diaphragm allow for improving the microphone performance and reducing the mechanical stiffness and air damping of the microphone. In this structure, the supply voltage is decreased due to the uniform deflection of the diaphragm due to the designed low-K (spring constant) structure. An analytical model of the structure for description of microphone behavior is presented. The proposed method for estimating the basic parameters of the microphone is based on the calculation of the spring constant using the energy method. The microphone is fabricated using only one mask to pattern the crab-shape diaphragm, resulting in a low-cost and easy fabrication process. The diaphragm size is 0.3 mm×0.3 mm, which is smaller than the conventional microelectromechanical systems capacitive microphone. The results show that the analytical equations have a good agreement with measurement results. The device has the pull-in voltage of 14.3 V, a resonant frequency of 90 kHz, an open-circuit sensitivity of 1.33 mV/Pa under bias voltage of 5 V. Comparing with previous works, this microphone has several advantages: SOI wafer decreases the fabrication process steps, the microphone is smaller than the previous works, and crab-shape diaphragm improves the microphone performances.
Phase Calibration of Microphones by Measurement in the Free-field
NASA Technical Reports Server (NTRS)
Shams, Qamar A.; Bartram, Scott M.; Humphreys, William M.; Zuckewar, Allan J.
2006-01-01
Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.
Genetic analysis of vertebrate sensory hair cell mechanosensation: the zebrafish circler mutants.
Nicolson, T; Rüsch, A; Friedrich, R W; Granato, M; Ruppersberg, J P; Nüsslein-Volhard, C
1998-02-01
The molecular basis of sensory hair cell mechanotransduction is largely unknown. In order to identify genes that are essential for mechanosensory hair cell function, we characterized a group of recently isolated zebrafish motility mutants. These mutants are defective in balance and swim in circles but have no obvious morphological defects. We examined the mutants using calcium imaging of acoustic-vibrational and tactile escape responses, high resolution microscopy of sensory neuroepithelia in live larvae, and recordings of extracellular hair cell potentials (microphonics). Based on the analyses, we have identified several classes of genes. Mutations in sputnik and mariner affect hair bundle integrity. Mutant astronaut and cosmonaut hair cells have relatively normal microphonics and thus appear to affect events downstream of mechanotransduction. Mutant orbiter, mercury, and gemini larvae have normal hair cell morphology and yet do not respond to acoustic-vibrational stimuli. The microphonics of lateral line hair cells of orbiter, mercury, and gemini larvae are absent or strongly reduced. Therefore, these genes may encode components of the transduction apparatus.
ERIC Educational Resources Information Center
Janota, Claus P.; Janota, Jeanette Olach
1991-01-01
Various candidate microphones were evaluated for acoustic coupling of hearing aids to a telephone receiver. Results from testing by 9 hearing-impaired adults found comparable listening performance with a pressure gradient microphone at a 10 decibel higher level of interfering noise than with a normal pressure-sensitive microphone. (Author/PB)
Methods for Room Acoustic Analysis and Synthesis using a Monopole-Dipole Microphone Array
NASA Technical Reports Server (NTRS)
Abel, J. S.; Begault, Durand R.; Null, Cynthia H. (Technical Monitor)
1998-01-01
In recent work, a microphone array consisting of an omnidirectional microphone and colocated dipole microphones having orthogonally aligned dipole axes was used to examine the directional nature of a room impulse response. The arrival of significant reflections was indicated by peaks in the power of the omnidirectional microphone response; reflection direction of arrival was revealed by comparing zero-lag crosscorrelations between the omnidirectional response and the dipole responses to the omnidirectional response power to estimate arrival direction cosines with respect to the dipole axes.
Vasta, Robert; Crandell, Ian; Millican, Anthony; House, Leanna; Smith, Eric
2017-10-13
Microphone sensor systems provide information that may be used for a variety of applications. Such systems generate large amounts of data. One concern is with microphone failure and unusual values that may be generated as part of the information collection process. This paper describes methods and a MATLAB graphical interface that provides rapid evaluation of microphone performance and identifies irregularities. The approach and interface are described. An application to a microphone array used in a wind tunnel is used to illustrate the methodology.
NASA Technical Reports Server (NTRS)
Zuckerwar, A. J. (Inventor)
1979-01-01
Pressure fluctuations in air or other gases in an area of elevated temperature are measured using a condenser microphone located in the area of elevated temperature and electronics for processing changes in the microphone capacitance located outside the area the area and connected to the microphone by means of high-temperature cable assembly. The microphone includes apparatus for decreasing the undesirable change in microphone sensitivity at high temperatures. The high temperature cable assembly operates as a half-wavelength transmission line in an AM carrier system and maintains a large temperature gradient between the two ends of the cable assembly. The processing electronics utilizes a voltage controlled oscillator for automatic tuning thereby increasing the sensitivity of the measuring apparatus.
Quantifying Errors in Jet Noise Research Due to Microphone Support Reflection
NASA Technical Reports Server (NTRS)
Nallasamy, Nambi; Bridges, James
2002-01-01
The reflection coefficient of a microphone support structure used insist noise testing is documented through tests performed in the anechoic AeroAcoustic Propulsion Laboratory. The tests involve the acquisition of acoustic data from a microphone mounted in the support structure while noise is generated from a known broadband source. The ratio of reflected signal amplitude to the original signal amplitude is determined by performing an auto-correlation function on the data. The documentation of the reflection coefficients is one component of the validation of jet noise data acquired using the given microphone support structure. Finally. two forms of acoustic material were applied to the microphone support structure to determine their effectiveness in reducing reflections which give rise to bias errors in the microphone measurements.
Speaker normalization for chinese vowel recognition in cochlear implants.
Luo, Xin; Fu, Qian-Jie
2005-07-01
Because of the limited spectra-temporal resolution associated with cochlear implants, implant patients often have greater difficulty with multitalker speech recognition. The present study investigated whether multitalker speech recognition can be improved by applying speaker normalization techniques to cochlear implant speech processing. Multitalker Chinese vowel recognition was tested with normal-hearing Chinese-speaking subjects listening to a 4-channel cochlear implant simulation, with and without speaker normalization. For each subject, speaker normalization was referenced to the speaker that produced the best recognition performance under conditions without speaker normalization. To match the remaining speakers to this "optimal" output pattern, the overall frequency range of the analysis filter bank was adjusted for each speaker according to the ratio of the mean third formant frequency values between the specific speaker and the reference speaker. Results showed that speaker normalization provided a small but significant improvement in subjects' overall recognition performance. After speaker normalization, subjects' patterns of recognition performance across speakers changed, demonstrating the potential for speaker-dependent effects with the proposed normalization technique.
NASA Astrophysics Data System (ADS)
Gurbani, Saumya S.; Wilkening, Paul; Zhao, Mingtao; Gonenc, Berk; Cheon, Gyeong Woo; Iordachita, Iulian I.; Chien, Wade; Taylor, Russell H.; Niparko, John K.; Kang, Jin U.
2014-05-01
Cochlear implantation offers the potential to restore sensitive hearing in patients with severe to profound deafness. However, surgical placement of the electrode array within the cochlea can produce trauma to sensorineural components, particularly if the initial turn of the cochlea is not successfully navigated as the array is advanced. In this work, we present a robot-mounted common-path swept-source optical coherence tomography endoscopic platform for three-dimensional (3-D) optical coherence tomography (OCT) registration and preoperative surgical planning for cochlear implant surgery. The platform is composed of a common-path 600-μm diameter fiber optic rotary probe attached to a five degrees of freedom robot capable of 1 μm precision movement. The system is tested on a dry fixed ex vivo human temporal bone, and we demonstrate the feasibility of a 3-D OCT registration of the cochlea to accurately describe the spatial and angular profiles of the canal formed by the scala tympani into the first cochlear turn.
Surgical evaluation of candidates for cochlear implants
NASA Technical Reports Server (NTRS)
Black, F. O.; Lilly, D. J.; Fowler, L. P.; Stypulkowski, P. H.
1987-01-01
The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.
Development and evaluation of the Nurotron 26-electrode cochlear implant system.
Zeng, Fan-Gang; Rebscher, Stephen J; Fu, Qian-Jie; Chen, Hongbin; Sun, Xiaoan; Yin, Li; Ping, Lichuan; Feng, Haihong; Yang, Shiming; Gong, Shusheng; Yang, Beibei; Kang, Hou-Yong; Gao, Na; Chi, Fanglu
2015-04-01
Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled
The impact of the microphone position on the frequency analysis of snoring sounds.
Herzog, Michael; Kühnel, Thomas; Bremert, Thomas; Herzog, Beatrice; Hosemann, Werner; Kaftan, Holger
2009-08-01
Frequency analysis of snoring sounds has been reported as a diagnostic tool to differentiate between different sources of snoring. Several studies have been published presenting diverging results of the frequency analyses of snoring sounds. Depending on the position of the used microphones, the results of the frequency analysis of snoring sounds vary. The present study investigated the influence of different microphone positions on the outcome of the frequency analysis of snoring sounds. Nocturnal snoring was recorded simultaneously at six positions (air-coupled: 30 cm middle, 100 cm middle, 30 cm lateral to both sides of the patients' head; body contact: neck and parasternal) in five patients. The used microphones had a flat frequency response and a similar frequency range (10/40 Hz-18 kHz). Frequency analysis was performed by fast Fourier transformation and frequency bands as well as peak intensities (Peaks 1-5) were detected. Air-coupled microphones presented a wider frequency range (60 Hz-10 kHz) compared to contact microphones. The contact microphone at cervical position presented a cut off at frequencies above 300 Hz, whereas the contact microphone at parasternal position revealed a cut off above 100 Hz. On an exemplary base, the study demonstrates that frequencies above 1,000 Hz do appear in complex snoring patterns, and it is emphasised that high frequencies are imported for the interpretation of snoring sounds with respect to the identification of the source of snoring. Contact microphones might be used in screening devices, but for a natural analysis of snoring sounds the use of air-coupled microphones is indispensable.
49 CFR 325.77 - Computation of open site requirements-nonstandard sites.
Code of Federal Regulations, 2010 CFR
2010-10-01
... microphone target point is other than 50 feet (15.2 m), the test site must be an open site within a radius... microphone target point. (b) Plan view diagrams of nonstandard test sites are shown in Figures 3 and 4... (18.3 m) distance between the microphone location point and the microphone target point. (See § 325.79...
49 CFR 325.77 - Computation of open site requirements-nonstandard sites.
Code of Federal Regulations, 2011 CFR
2011-10-01
... microphone target point is other than 50 feet (15.2 m), the test site must be an open site within a radius... microphone target point. (b) Plan view diagrams of nonstandard test sites are shown in Figures 3 and 4... (18.3 m) distance between the microphone location point and the microphone target point. (See § 325.79...
NASA Technical Reports Server (NTRS)
Cicon, D. E.; Sofrin, T. G.
1995-01-01
This report describes a procedure for enhancing the use of the basic rotating microphone system so as to determine the forward propagating mode components of the acoustic field in the inlet duct at the microphone plane in order to predict more accurate far-field radiation patterns. In addition, a modification was developed to obtain, from the same microphone readings, the forward acoustic modes generated at the fan face, which is generally some distance downstream of the microphone plane. Both these procedures employ computer-simulated calibrations of sound propagation in the inlet duct, based upon the current radiation code. These enhancement procedures were applied to previously obtained rotating microphone data for the 17-inch ADP fan. The forward mode components at the microphone plane were obtained and were used to compute corresponding far-field directivities. The second main task of the program involved finding the forward wave modes generated at the fan face in terms of the same total radial mode structure measured at the microphone plane. To obtain satisfactory results with the ADP geometry it was necessary to limit consideration to the propagating modes. Sensitivity studies were also conducted to establish guidelines for use in other fan configurations.
Technological, biological, and acoustical constraints to music perception in cochlear implant users.
Limb, Charles J; Roy, Alexis T
2014-02-01
Despite advances in technology, the ability to perceive music remains limited for many cochlear implant users. This paper reviews the technological, biological, and acoustical constraints that make music an especially challenging stimulus for cochlear implant users, while highlighting recent research efforts to overcome these shortcomings. The limitations of cochlear implant devices, which have been optimized for speech comprehension, become evident when applied to music, particularly with regards to inadequate spectral, fine-temporal, and dynamic range representation. Beyond the impoverished information transmitted by the device itself, both peripheral and central auditory nervous system deficits are seen in the presence of sensorineural hearing loss, such as auditory nerve degeneration and abnormal auditory cortex activation. These technological and biological constraints to effective music perception are further compounded by the complexity of the acoustical features of music itself that require the perceptual integration of varying rhythmic, melodic, harmonic, and timbral elements of sound. Cochlear implant users not only have difficulty perceiving spectral components individually (leading to fundamental disruptions in perception of pitch, melody, and harmony) but also display deficits with higher perceptual integration tasks required for music perception, such as auditory stream segregation. Despite these current limitations, focused musical training programs, new assessment methods, and improvements in the representation and transmission of the complex acoustical features of music through technological innovation offer the potential for significant advancements in cochlear implant-mediated music perception. Copyright © 2013 Elsevier B.V. All rights reserved.
Song, Mee Hyun; Bae, Mi Ran; Kim, Hee Nam; Lee, Won-Sang; Yang, Won Sun; Choi, Jae Young
2010-08-01
Cochlear implantation in patients with narrow internal auditory canal (IAC) can result in variable outcomes; however, preoperative evaluations have limitations in accurately predicting outcomes. In this study, we analyzed the outcomes of cochlear implantation in patients with narrow IAC and correlated the intracochlear electrically evoked auditory brainstem response (EABR) findings to postoperative performance to determine the prognostic significance of intracochlear EABR. Retrospective case series at a tertiary hospital. Thirteen profoundly deaf patients with narrow IAC who received cochlear implantation from 2002 to 2008 were included in this study. Postoperative performance was evaluated after at least 12 months of follow-up, and postoperative intracochlear EABR was measured to determine its correlation with outcome. The clinical significance of electrically evoked compound action potential (ECAP) was also analyzed. Patients with narrow IAC showed postoperative auditory performances ranging from CAP 0 to 4 after cochlear implantation. Intracochlear EABR measured postoperatively demonstrated prognostic value in the prediction of long-term outcomes, whereas ECAP measurements failed to show a significant correlation with outcome. Consistent with the advantages of intracochlear EABR over extracochlear EABR, this study demonstrates that intracochlear EABR has prognostic significance in predicting long-term outcomes in patients with narrow IAC. Intracochlear EABR measured either intraoperatively or in the early postoperative period may play an important role in deciding whether to continue with auditory rehabilitation using a cochlear implant or to switch to an auditory brainstem implant so as not to miss the optimal timing for language development.
A dynamic multi-channel speech enhancement system for distributed microphones in a car environment
NASA Astrophysics Data System (ADS)
Matheja, Timo; Buck, Markus; Fingscheidt, Tim
2013-12-01
Supporting multiple active speakers in automotive hands-free or speech dialog applications is an interesting issue not least due to comfort reasons. Therefore, a multi-channel system for enhancement of speech signals captured by distributed distant microphones in a car environment is presented. Each of the potential speakers in the car has a dedicated directional microphone close to his position that captures the corresponding speech signal. The aim of the resulting overall system is twofold: On the one hand, a combination of an arbitrary pre-defined subset of speakers' signals can be performed, e.g., to create an output signal in a hands-free telephone conference call for a far-end communication partner. On the other hand, annoying cross-talk components from interfering sound sources occurring in multiple different mixed output signals are to be eliminated, motivated by the possibility of other hands-free applications being active in parallel. The system includes several signal processing stages. A dedicated signal processing block for interfering speaker cancellation attenuates the cross-talk components of undesired speech. Further signal enhancement comprises the reduction of residual cross-talk and background noise. Subsequently, a dynamic signal combination stage merges the processed single-microphone signals to obtain appropriate mixed signals at the system output that may be passed to applications such as telephony or a speech dialog system. Based on signal power ratios between the particular microphone signals, an appropriate speaker activity detection and therewith a robust control mechanism of the whole system is presented. The proposed system may be dynamically configured and has been evaluated for a car setup with four speakers sitting in the car cabin disturbed in various noise conditions.
Sub-Surface Windscreen for Outdoor Measurement of Infrasound
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor)
2014-01-01
A windscreen is configured for measuring outdoor infrasonic sound. The windscreen includes a container and a microphone. The container defines a chamber. The microphone is disposed in the chamber and can be operatively supported by the floor. The microphone is configured for detecting infrasonic sound. The container is advantageously formed from material that exhibits an acoustic impedance of between 0 and approximately 3150 times the acoustic impedance of air. A reflector plate may be disposed in the container. The reflector plate operatively can support the microphone and provides a doubling effect of infrasonic pressure at the microphone.
NASA Astrophysics Data System (ADS)
Dehé, Alfons
2017-06-01
After decades of research and more than ten years of successful production in very high volumes Silicon MEMS microphones are mature and unbeatable in form factor and robustness. Audio applications such as video, noise cancellation and speech recognition are key differentiators in smart phones. Microphones with low self-noise enable those functions. Backplate-free microphones enter the signal to noise ratios above 70dB(A). This talk will describe state of the art MEMS technology of Infineon Technologies. An outlook on future technologies such as the comb sensor microphone will be given.
Modification of otoacoustic emissions following ear-level exposure to MP3 player music.
Bhagat, Shaum P; Davis, Anne M
2008-12-01
The purpose of this study was to examine if a pre-determined exposure level and duration of MP3 player music would result in significant changes in cochlear function when measured with audiometric and physiological methods. Distortion-product otoacoustic emissions (DPOAEs), synchronized spontaneous otoacoustic emissions (SSOAEs), and hearing thresholds were measured in 20 normal-hearing adults before and after a 30-minute MP3 player music exposure. DPOAEs were acquired with 65/45 dB SPL primary tones (f(2)=0.842-7.996 kHz) with a frequency resolution of 8 points/octave. A probe microphone system recorded ear-canal music levels and was used to equalize levels at approximately 85 dBC across individuals during the music presentation. Comparison of pre- and post-exposure measurements revealed no significant differences in hearing thresholds, but DPOAE levels in half-octave bands centered from 1.4-6.0 kHz were significantly reduced following the music exposure. Post-exposure shifts in SSOAE frequency and level were highly variable in individuals identified with SSOAEs. The results for the exposure conditions explored in this study indicate that changes in otoacoustic emissions may precede the development of music-induced hearing threshold shifts.
Analog Binaural Circuits for Detecting and Locating Leaks
NASA Technical Reports Server (NTRS)
Hartley, Frank T.
2003-01-01
Very-large-scale integrated (VLSI) analog binaural signal-processing circuits have been proposed for use in detecting and locating leaks that emit noise in the ultrasonic frequency range. These circuits would be designed to function even in the presence of intense lower-frequency background noise that could include sounds associated with flow and pumping. Each of the proposed circuits would include the approximate electronic equivalent of a right and a left cochlea plus correlator circuits. A pair of transducers (microphones or accelerometers), corresponding to right and left ears, would provide the inputs to their respective cochleas from different locations (e.g., from different positions along a pipe). The correlation circuits plus some additional external circuits would determine the difference between the times of arrival of a common leak sound at the two transducers. Then the distance along the pipe from either transducer to the leak could be estimated from the time difference and the speed of sound along the pipe. If three or more pairs of transducers and cochlear/correlator circuits were available and could suitably be positioned, it should be possible to locate a leak in three dimensions by use of sound propagating through air.
Mechanoelectrical transduction of adult outer hair cells studied in a gerbil hemicochlea.
He, David Z Z; Jia, Shuping; Dallos, Peter
2004-06-17
Sensory receptor cells of the mammalian cochlea are morphologically and functionally dichotomized. Inner hair cells transmit auditory information to the brain, whereas outer hair cells (OHC) amplify the mechanical signal, which is then transduced by inner hair cells. Amplification by OHCs is probably mediated by their somatic motility in a mechanical feedback process. OHC motility in vivo is thought to be driven by the cell's receptor potential. The first steps towards the generation of the receptor potential are the deflection of the stereociliary bundle, and the subsequent flow of transducer current through the mechanosensitive transducer channels located at their tips. Quantitative relations between transducer currents and basilar membrane displacements are lacking, as well as their variation along the cochlear length. To address this, we simultaneously recorded OHC transducer currents (or receptor potentials) and basilar membrane motion in an excised and bisected cochlea, the hemicochlea. This preparation permits recordings from adult OHCs at various cochlear locations while the basilar membrane is mechanically stimulated. Furthermore, the stereocilia are deflected by the same means of stimulation as in vivo. Here we show that asymmetrical transducer currents and receptor potentials are significantly larger than previously thought, they possess a highly restricted dynamic range and strongly depend on cochlear location.
2013-04-01
Assessment of Operational Progress of NASA Langley Developed Windshield and Microphone for Infrasound by W.C. Kirkpatrick Alberts, II...Windshield and Microphone for Infrasound W.C. Kirkpatrick Alberts, II, Stephen M. Tenney, and John M. Noble Sensors and Electron Devices Directorate...2013 4. TITLE AND SUBTITLE Assessment of Operational Progress of NASA Langley Developed Windshield and Microphone for Infrasound 5a. CONTRACT
Mei, Ling; Chen, Jin; Zong, Liang; Zhu, Yan; Liang, Chun; Jones, Raleigh O; Zhao, Hong-Bo
2017-12-01
Digenic Connexin26 (Cx26, GJB2) and Cx30 (GJB6) heterozygous mutations are the second most frequent cause of recessive deafness in humans. However, the underlying deafness mechanism remains unclear. In this study, we created different double Cx26 and Cx30 heterozygous (Cx26 +/- /Cx30 +/- ) mouse models to investigate the underlying pathological changes and deafness mechanism. We found that double Cx26 +/- /Cx30 +/- heterozygous mice had hearing loss. Endocochlear potential (EP), which is a driving force for hair cells producing auditory receptor current, was reduced. However, unlike Cx26 homozygous knockout (Cx26 -/- ) mice, the cochlea in Cx26 +/- /Cx30 +/- mice displayed normal development and had no apparent hair cell degeneration. Gap junctions (GJs) in the cochlea form two independent networks: the epithelial cell GJ network in the organ of Corti and the connective tissue GJ network in the cochlear lateral wall. We further found that double heterozygous deletion of Cx26 and Cx30 in the epithelial cells did not reduce EP and had normal hearing, suggesting that Cx26 +/- /Cx30 +/- may mainly impair gap junctional functions in the cochlear lateral wall and lead to EP reduction and hearing loss. Most of Cx26 and Cx30 in the cochlear lateral wall co-expressed in the same gap junctional plaques. Moreover, sole Cx26 +/- or Cx30 +/- heterozygous mice had no hearing loss. These data further suggest that digenic Cx26 and Cx30 mutations may impair heterozygous coupling of Cx26 and Cx30 in the cochlear lateral wall to reduce EP, thereby leading to hearing loss. Copyright © 2017 Elsevier Inc. All rights reserved.
Systematic review of compound action potentials as predictors for cochlear implant performance.
van Eijl, Ruben H M; Buitenhuis, Patrick J; Stegeman, Inge; Klis, Sjaak F L; Grolman, Wilko
2017-02-01
The variability in speech perception between cochlear implant users is thought to result from the degeneration of the auditory nerve. Degeneration of the auditory nerve, histologically assessed, correlates with electrophysiologically acquired measures, such as electrically evoked compound action potentials (eCAPs) in experimental animals. To predict degeneration of the auditory nerve in humans, where histology is impossible, this paper reviews the correlation between speech perception and eCAP recordings in cochlear implant patients. PubMed and Embase. We performed a systematic search for articles containing the following major themes: cochlear implants, evoked potentials, and speech perception. Two investigators independently conducted title-abstract screening, full-text screening, and critical appraisal. Data were extracted from the remaining articles. Twenty-five of 1,429 identified articles described a correlation between speech perception and eCAP attributes. Due to study heterogeneity, a meta-analysis was not feasible, and studies were descriptively analyzed. Several studies investigating presence of the eCAP, recovery time constant, slope of the amplitude growth function, and spatial selectivity showed significant correlations with speech perception. In contrast, neural adaptation, eCAP threshold, and change with varying interphase gap did not significantly correlate with speech perception in any of the identified studies. Significant correlations between speech perception and parameters obtained through eCAP recordings have been documented in literature; however, reporting was ambiguous. There is insufficient evidence for eCAPs as a predictive factor for speech perception. More research is needed to further investigate this relation. Laryngoscope, 2016 127:476-487, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Uloza, Virgilijus; Padervinskis, Evaldas; Uloziene, Ingrida; Saferis, Viktoras; Verikas, Antanas
2015-09-01
The aim of the present study was to evaluate the reliability of the measurements of acoustic voice parameters obtained simultaneously using oral and contact (throat) microphones and to investigate utility of combined use of these microphones for voice categorization. Voice samples of sustained vowel /a/ obtained from 157 subjects (105 healthy and 52 pathological voices) were recorded in a soundproof booth simultaneously through two microphones: oral AKG Perception 220 microphone (AKG Acoustics, Vienna, Austria) and contact (throat) Triumph PC microphone (Clearer Communications, Inc, Burnaby, Canada) placed on the lamina of thyroid cartilage. Acoustic voice signal data were measured for fundamental frequency, percent of jitter and shimmer, normalized noise energy, signal-to-noise ratio, and harmonic-to-noise ratio using Dr. Speech software (Tiger Electronics, Seattle, WA). The correlations of acoustic voice parameters in vocal performance were statistically significant and strong (r = 0.71-1.0) for the entire functional measurements obtained for the two microphones. When classifying into healthy-pathological voice classes, the oral-shimmer revealed the correct classification rate (CCR) of 75.2% and the throat-jitter revealed CCR of 70.7%. However, combination of both throat and oral microphones allowed identifying a set of three voice parameters: throat-signal-to-noise ratio, oral-shimmer, and oral-normalized noise energy, which provided the CCR of 80.3%. The measurements of acoustic voice parameters using a combination of oral and throat microphones showed to be reliable in clinical settings and demonstrated high CCRs when distinguishing the healthy and pathological voice patient groups. Our study validates the suitability of the throat microphone signal for the task of automatic voice analysis for the purpose of voice screening. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
American School Band Directors Association, Newark, OH.
The guide, one in a series of committee reports relating to school band performance, organization, and equipment needs, examines the relationship between microphones and tape recordings. The guide is presented in nine sections. Section I identifies types of microphones (carbon, crystal and ceramic, dynamic, condenser, and ribbon). Section II…
Chung, King; Mongeau, Luc; McKibben, Nicholas
2009-04-01
Wind noise can be a significant problem for hearing instrument users. This study examined the polar characteristics of flow noise at outputs of two behind-the-ear digital hearing aids, and a microphone mounted on the surface of a cylinder at flow velocities ranging from a gentle breeze (4.5 m/s) to a strong gale (22.5 m/s) . The hearing aids were programed in an anechoic chamber, and tested in a quiet wind tunnel for flow noise recordings. Flow noise levels were estimated by normalizing the overall gain of the hearing aids to 0 dB. The results indicated that the two hearing aids had similar flow noise characteristics: The noise level was generally the lowest when the microphone faced upstream, higher when the microphone faced downstream, and the highest for frontal and rearward incidence angles. Directional microphones often generated higher flow noise level than omnidirectional microphones but they could reduce far-field background noise, resulting in a lower ambient noise level than omnidirectional microphones. Data for the academic microphone- on-cylinder configuration suggested that both turbulence and flow impingement might have contributed to the generation of flow noise in the hearing aids. Clinical and engineering design applications are discussed.
Barrera-Figueroa, Salvador; Rasmussen, Knud; Jacobsen, Finn
2009-10-01
Typically, numerical calculations of the pressure, free-field, and random-incidence response of a condenser microphone are carried out on the basis of an assumed displacement distribution of the diaphragm of the microphone; the conventional assumption is that the displacement follows a Bessel function. This assumption is probably valid at frequencies below the resonance frequency. However, at higher frequencies the movement of the membrane is heavily coupled with the damping of the air film between membrane and backplate and with resonances in the back chamber of the microphone. A solution to this problem is to measure the velocity distribution of the membrane by means of a non-contact method, such as laser vibrometry. The measured velocity distribution can be used together with a numerical formulation such as the boundary element method for estimating the microphone response and other parameters, e.g., the acoustic center. In this work, such a hybrid method is presented and examined. The velocity distributions of a number of condenser microphones have been determined using a laser vibrometer, and these measured velocity distributions have been used for estimating microphone responses and other parameters. The agreement with experimental data is generally good. The method can be used as an alternative for validating the parameters of the microphones determined by classical calibration techniques.
Chung, King
2004-01-01
This review discusses the challenges in hearing aid design and fitting and the recent developments in advanced signal processing technologies to meet these challenges. The first part of the review discusses the basic concepts and the building blocks of digital signal processing algorithms, namely, the signal detection and analysis unit, the decision rules, and the time constants involved in the execution of the decision. In addition, mechanisms and the differences in the implementation of various strategies used to reduce the negative effects of noise are discussed. These technologies include the microphone technologies that take advantage of the spatial differences between speech and noise and the noise reduction algorithms that take advantage of the spectral difference and temporal separation between speech and noise. The specific technologies discussed in this paper include first-order directional microphones, adaptive directional microphones, second-order directional microphones, microphone matching algorithms, array microphones, multichannel adaptive noise reduction algorithms, and synchrony detection noise reduction algorithms. Verification data for these technologies, if available, are also summarized. PMID:15678225
The Effect of Microphone Type on Acoustical Measures of Synthesized Vowels.
Kisenwether, Jessica Sofranko; Sataloff, Robert T
2015-09-01
The purpose of this study was to compare microphones of different directionality, transducer type, and cost, with attention to their effects on acoustical measurements of period perturbation, amplitude perturbation, and noise using synthesized sustained vowel samples. This was a repeated measures design. Synthesized sustained vowel stimuli (with known acoustic characteristics and systematic changes in jitter, shimmer, and noise-to-harmonics ratio) were recorded by a variety of dynamic and condenser microphones. Files were then analyzed for mean fundamental frequency (fo), fo standard deviation, absolute jitter, shimmer in dB, peak-to-peak amplitude variation, and noise-to-harmonics ratio. Acoustical measures following recording were compared with the synthesized, known acoustical measures before recording. Although informal analyses showed some differences among microphones, and analyses of variance showed that type of microphone is a significant predictor, t-tests revealed that none of the microphones generated different means compared with the generated acoustical measures. In this sample, microphone type, directionality, and cost did not have a significant effect on the validity of acoustic measures. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
ZnO thin film piezoelectric micromachined microphone with symmetric composite vibrating diaphragm
NASA Astrophysics Data System (ADS)
Li, Junhong; Wang, Chenghao; Ren, Wei; Ma, Jun
2017-05-01
Residual stress is an important factor affecting the sensitivity of piezoelectric micromachined microphone. A symmetric composite vibrating diaphragm was adopted in the micro electro mechanical systems piezoelectric microphone to decrease the residual stress and improve the sensitivity of microphone in this paper. The ZnO film was selected as piezoelectric materials of microphone for its higher piezoelectric coefficient d 31 and lower relative dielectric constant. The thickness optimization of piezoelectric film on square diaphragm is difficult to be fulfilled by analytic method. To optimize the thickness of ZnO films, the stress distribution in ZnO film was analyzed by finite element method and the average stress in different thickness of ZnO films was given. The ZnO films deposited using dc magnetron sputtering exhibits a densely packed structure with columnar crystallites preferentially oriented along (002) plane. The diaphragm of microphone fabricated by micromachining techniques is flat and no wrinkling at corners, and the sensitivity of microphone is higher than 1 mV Pa-1. These results indicate the diaphragm has lower residual stress.
Cochlear implant users move in time to the beat of drum music.
Phillips-Silver, Jessica; Toiviainen, Petri; Gosselin, Nathalie; Turgeon, Christine; Lepore, Franco; Peretz, Isabelle
2015-03-01
Cochlear implant users show a profile of residual, yet poorly understood, musical abilities. An ability that has received little to no attention in this population is entrainment to a musical beat. We show for the first time that a heterogeneous group of cochlear implant users is able to find the beat and move their bodies in time to Latin Merengue music, especially when the music is presented in unpitched drum tones. These findings not only reveal a hidden capacity for feeling musical rhythm through the body in the deaf and hearing impaired population, but illuminate promising avenues for designing early childhood musical training that can engage implanted children in social musical activities with benefits potentially extending to non-musical domains. Copyright © 2015 Elsevier B.V. All rights reserved.
Moore, Brian C J
2003-03-01
To review how the properties of sounds are "coded" in the normal auditory system and to discuss the extent to which cochlear implants can and do represent these codes. Data are taken from published studies of the response of the cochlea and auditory nerve to simple and complex stimuli, in both the normal and the electrically stimulated ear. REVIEW CONTENT: The review describes: 1) the coding in the normal auditory system of overall level (which partly determines perceived loudness), spectral shape (which partly determines perceived timbre and the identity of speech sounds), periodicity (which partly determines pitch), and sound location; 2) the role of the active mechanism in the cochlea, and particularly the fast-acting compression associated with that mechanism; 3) the neural response patterns evoked by cochlear implants; and 4) how the response patterns evoked by implants differ from those observed in the normal auditory system in response to sound. A series of specific issues is then discussed, including: 1) how to compensate for the loss of cochlear compression; 2) the effective number of independent channels in a normal ear and in cochlear implantees; 3) the importance of independence of responses across neurons; 4) the stochastic nature of normal neural responses; 5) the possible role of across-channel coincidence detection; and 6) potential benefits of binaural implantation. Current cochlear implants do not adequately reproduce several aspects of the neural coding of sound in the normal auditory system. Improved electrode arrays and coding systems may lead to improved coding and, it is hoped, to better performance.
Athalye, Sheetal; Archbold, Sue; Mulla, Imran; Lutman, Mark; Nikolopoulous, Thomas
2015-09-01
The objective of this survey was to explore the perceptions of implant users/carers and professionals across the UK about current and future cochlear implant service delivery and the challenges. Data were collected via an online questionnaire consisting of totally 22 questions. The questionnaire contained both open- and close-ended questions. Totally, seven hundred and forty-eight responses were received. In spite of the wide range of respondents, there was a broad consensus of opinion across groups. The majority of participants were satisfied with the service they currently receive, but wanted some changes. They reported their current experience of implant services to be mainly driven by decisions made by the implant team. For the future, they preferred the service to be mainly driven by decisions made jointly by the team and the user and/or parent/carer. The majority of participants wanted the cochlear implant services to be integrated into local audiology and other services such as education. Restrictions on number of candidates funded and political decisions and issues were seen as major challenges. Qualitative analysis of the open-ended responses supported the questionnaire responses. This research highlighted the benefits and limitations of the current cochlear implant service delivery as well as the potential implications for the long term. While respondents were generally happy with the current cochlear implant service provision, they expressed some concerns about the long-term sustainability and management, wanting integration into the local services, and more involvement of parents and users in decisions.
Auditory maturation in premature infants: a potential pitfall for early cochlear implantation.
Hof, Janny R; Stokroos, Robert J; Wix, Eduard; Chenault, Mickey; Gelders, Els; Brokx, Jan
2013-08-01
To describe spontaneous hearing improvement in the first years of life of a number of preterm neonates relative to cochlear implant candidacy. Retrospective case study. Hearing levels of 14 preterm neonates (mean gestational age at birth = 29 weeks) referred after newborn hearing screening were evaluated. Initial hearing thresholds ranged from 40 to 105 dBHL (mean = 85 dBHL). Hearing level improved to normal levels for four neonates and to moderate levels for five, whereas for five neonates, no improvement in hearing thresholds was observed and cochlear implantation was recommended. Three of the four neonates in whom the hearing improved to normal levels were born prior to 28 weeks gestational age. Hearing improvement was mainly observed prior to a gestational age of 80 weeks. Delayed maturation of an immature auditory pathway might be an important reason for referral after newborn hearing screening in premature infants. Caution is advised regarding early cochlear implantation in preterm born infants. Audiological follow-ups until at least 80 weeks gestational age are therefore recommended. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S
2006-05-01
X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.
Optical coherence tomography as a guide for cochlear implant surgery?
NASA Astrophysics Data System (ADS)
Just, T.; Lankenau, E.; Hüttmann, G.; Pau, H. W.
2008-02-01
To assess the potential use of optical coherence tomography (OCT) in cochlear implant surgery, OCT was applied in human temporal bones before cochleostomy. The question was whether OCT might provide information about the cochlear topography, especially about the site of the scala tympani. OCT was carried out on human temporal bone preparations, in which the cochleostomy was performed leaving the membranous labyrinth and the fluid-filled inner ear intact. A specially equipped operating microscope with integrated OCT prototype was used. Spectral-domain (SD)-OCT was used for all investigations. On all scans, OCT supplied information about inner ear structures, such as scala tympani, scala vestibuli while the membranous labyrinth was still intact. In the fresh temporal bone the scala media, basilar membrane and the Reissner's membrane were identified. This OCT study clearly documents the possibility to identify inner ear structures, especially the scala tympani without opening its enveloping membranes. These findings may have an impact on cochlear implant surgery, especially as an orientation guide to localize the scala tympani precisely before opening the fluid filled inner ear.
Kendrick, Paul; von Hünerbein, Sabine; Cox, Trevor J
2016-07-01
Microphone wind noise can corrupt outdoor recordings even when wind shields are used. When monitoring wind turbine noise, microphone wind noise is almost inevitable because measurements cannot be made in still conditions. The effect of microphone wind noise on two amplitude modulation (AM) metrics is quantified in a simulation, showing that even at low wind speeds of 2.5 m/s errors of over 4 dBA can result. As microphone wind noise is intermittent, a wind noise detection algorithm is used to automatically find uncorrupted sections of the recording, and so recover the true AM metrics to within ±2/±0.5 dBA.
Fiber optic microphone with large dynamic range based on bi-fiber Fabry-Perot cavity
NASA Astrophysics Data System (ADS)
Cheng, Jin; Lu, Dan-feng; Gao, Ran; Qi, Zhi-mei
2017-10-01
In this paper, we report a fiber optic microphone with a large dynamic range. The probe of microphone consists of bi-fiber Fabry-Perot cavity architecture. The wavelength of the working laser is about 1552.05nm. At this wavelength, the interference spectroscopies of these two fiber Fabry-Perot cavities have a quadrature shift. So the outputs of these two fiber Fabry-Perot sensors are orthogonal signal. By using orthogonal signal demodulation method, this microphone can output a signal of acoustic wave. Due to no relationship between output signal and the linear region on interference spectroscopy, the microphones have a large maximum acoustic pressure above 125dB.
Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies
Busi, Micol; Rosignoli, Monica; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Martini, Alessandro
2015-01-01
Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a negative prognostic factor that is made worse by the concomitant presence of cochlear malformations. Common cavity and stenosis of the internal auditory canal (less than 2 mm) are negative prognostic factors even if brain lesions are absent. PMID:26236732
Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies.
Busi, Micol; Rosignoli, Monica; Castiglione, Alessandro; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Granieri, Enrico; Martini, Alessandro
2015-01-01
Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a negative prognostic factor that is made worse by the concomitant presence of cochlear malformations. Common cavity and stenosis of the internal auditory canal (less than 2 mm) are negative prognostic factors even if brain lesions are absent.
Cochlear Implantation in Older Adults
Lin, Frank R.; Chien, Wade W.; Li, Lingsheng; Niparko, John K.; Francis, Howard W.
2012-01-01
Cochlear implants allow individuals with severe-to-profound hearing loss access to sound and spoken language. The number of older adults in the United States who are potential candidates for cochlear implantation is approximately 150,000 and will continue to increase with the aging of the population. Should cochlear implantation (CI) be routinely recommended for these older adults, and do these individuals benefit from CI? We reviewed our 12 year experience with cochlear implantation in adults ≥60 years (n = 445) at Johns Hopkins to investigate the impact of CI on speech understanding and to identify factors associated with speech performance. Complete data on speech outcomes at baseline and 1 year post-CI were available for 83 individuals. Our results demonstrate that cochlear implantation in adults ≥60 years consistently improved speech understanding scores with a mean increase of 60. 0% (S. D. 24. 1) on HINT sentences in quiet . The magnitude of the gain in speech scores was negatively associated with age at implantation such that for every increasing year of age at CI the gain in speech scores was 1. 3 percentage points less (95% CI: 0. 6 – 1. 9) after adjusting for age at hearing loss onset. Conversely, individuals with higher pre-CI speech scores (HINT scores between 40–60%) had significantly greater post-CI speech scores by a mean of 10. 0 percentage points (95% CI: 0. 4 – 19. 6) than those with lower pre-CI speech scores (HINT <40%) after adjusting for age at CI and age at hearing loss onset. These results suggest that older adult CI candidates who are younger at implantation and with higher preoperative speech scores obtain the highest speech understanding scores after cochlear implantation with possible implications for current Medicare policy. Finally, we provide an extended discussion of the epidemiology and impact of hearing loss in older adults. Future research of CI in older adults should expand beyond simple speech outcomes to take into account the broad cognitive, social, and physical functioning outcomes that are likely detrimentally impacted by hearing loss and may be mitigated by cochlear implantation. PMID:22932787
Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego
2014-03-01
To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.
A speech processing study using an acoustic model of a multiple-channel cochlear implant
NASA Astrophysics Data System (ADS)
Xu, Ying
1998-10-01
A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and channel numbers were not beneficial. Manipulations of stimulation rate and number of activated channels did not appreciably affect consonant recognition. These results suggest that overall speech performance may improve by appropriately increasing stimulation rate and number of activated channels. Future revision of this acoustic model is necessary to provide more accurate amplitude representation of speech.
50 years of progress in microphone arrays for speech processing
NASA Astrophysics Data System (ADS)
Elko, Gary W.; Frisk, George V.
2004-10-01
In the early 1980s, Jim Flanagan had a dream of covering the walls of a room with microphones. He occasionally referred to this concept as acoustic wallpaper. Being a new graduate in the field of acoustics and signal processing, it was fortunate that Bell Labs was looking for someone to investigate this area of microphone arrays for telecommunication. The job interview was exciting, with all of the big names in speech signal processing and acoustics sitting in the audience, many of whom were the authors of books and articles that were seminal contributions to the fields of acoustics and signal processing. If there ever was an opportunity of a lifetime, this was it. Fortunately, some of the work had already begun, and Sessler and West had already laid the groundwork for directional electret microphones. This talk will describe some of the very early work done at Bell Labs on microphone arrays and reflect on some of the many systems, from large 400-element arrays, to small two-microphone arrays. These microphone array systems were built under Jim Flanagan's leadership in an attempt to realize his vision of seamless hands-free speech communication between people and the communication of people with machines.
Multi-criteria anomaly detection in urban noise sensor networks.
Dauwe, Samuel; Oldoni, Damiano; De Baets, Bernard; Van Renterghem, Timothy; Botteldooren, Dick; Dhoedt, Bart
2014-01-01
The growing concern of citizens about the quality of their living environment and the emergence of low-cost microphones and data acquisition systems triggered the deployment of numerous noise monitoring networks spread over large geographical areas. Due to the local character of noise pollution in an urban environment, a dense measurement network is needed in order to accurately assess the spatial and temporal variations. The use of consumer grade microphones in this context appears to be very cost-efficient compared to the use of measurement microphones. However, the lower reliability of these sensing units requires a strong quality control of the measured data. To automatically validate sensor (microphone) data, prior to their use in further processing, a multi-criteria measurement quality assessment model for detecting anomalies such as microphone breakdowns, drifts and critical outliers was developed. Each of the criteria results in a quality score between 0 and 1. An ordered weighted average (OWA) operator combines these individual scores into a global quality score. The model is validated on datasets acquired from a real-world, extensive noise monitoring network consisting of more than 50 microphones. Over a period of more than a year, the proposed approach successfully detected several microphone faults and anomalies.
Mens, Lucas H M
2011-01-01
To test speech understanding in noise using array microphones integrated in an eyeglass device and to test if microphones placed anteriorly at the temple provide better directivity than above the pinna. Sentences were presented from the front and uncorrelated noise from 45, 135, 225 and 315°. Fifteen hearing impaired participants with a significant speech discrimination loss were included, as well as 5 normal hearing listeners. The device (Varibel) improved speech understanding in noise compared to most conventional directional devices with a directional benefit of 5.3 dB in the asymmetric fit mode, which was not significantly different from the bilateral fully directional mode (6.3 dB). Anterior microphones outperformed microphones at a conventional position above the pinna by 2.6 dB. By integrating microphones in an eyeglass frame, a long array can be used resulting in a higher directionality index and improved speech understanding in noise. An asymmetric fit did not significantly reduce performance and can be considered to increase acceptance and environmental awareness. Directional microphones at the temple seemed to profit more from the head shadow than above the pinna, better suppressing noise from behind the listener.
Hodgetts, William; Scott, Dylan; Maas, Patrick; Westover, Lindsey
2018-03-23
To determine if a newly-designed, forehead-mounted surface microphone would yield equivalent estimates of audibility when compared to audibility measured with a skull simulator for adult bone conduction users. Data was analyzed using a within subjects, repeated measures design. There were two different sensors (skull simulator and surface microphone) measuring the same hearing aid programmed to the same settings for all subjects. We were looking for equivalent results. Twenty-one adult percutaneous bone conduction users (12 females and 9 males) were recruited for this study. Mean age was 54.32 years with a standard deviation of 14.51 years. Nineteen of the subjects had conductive/mixed hearing loss and two had single-sided deafness. To define audibility, we needed to establish two things: (1) in situ-level thresholds at each audiometric frequency in force (skull simulator) and in sound pressure level (SPL; surface microphone). Next, we measured the responses of the preprogrammed test device in force on the skull simulator and in SPL on the surface mic in response to pink noise at three input levels: 55, 65, and 75 dB SPL. The skull simulator responses were converted to real head force responses by means of an individual real head to coupler difference transform. Subtracting the real head force level thresholds from the real head force output of the test aid yielded the audibility for each audiometric frequency for the skull simulator. Subtracting the SPL thresholds from the surface microphone from the SPL output of the test aid yielded the audibility for each audiometric frequency for the surface microphone. The surface microphone was removed and retested to establish the test-retest reliability of the tool. We ran a 2 (sensor) × 3 (input level) × 10 (frequency) mixed analysis of variance to determine if there were any significant main effects and interactions. There was a significant three-way interaction, so we proceeded to explore our planned comparisons. There were 90 planned comparisons of interest, three at each frequency (3 × 10) for the three input levels (30 × 3). Therefore, to minimize a type 1 error associated with multiple comparisons, we adjusted alpha using the Holm-Bonferroni method. There were five comparisons that yielded significant differences between the skull simulator and surface microphone (test and retest) in the estimation of audibility. However, the mean difference in these effects was small at 3.3 dB. Both sensors yielded equivalent results for the majority of comparisons. Models of bone conduction devices that have intact skin cannot be measured with the skull simulator. This study is the first to present and evaluate a new tool for bone conduction verification. The surface microphone is capable of yielding equivalent audibility measurements as the skull simulator for percutaneous bone conduction users at multiple input levels. This device holds potential for measuring other bone conduction devices (Sentio, BoneBridge, Attract, Soft headband devices) that do not have a percutaneous implant.
On the stability and compressive nonlinearity of a physiologically based model of the cochlea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nankali, Amir; Grosh, Karl; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
Hearing relies on a series of coupled electrical, acoustical (fluidic) and mechanical interactions inside the cochlea that enable sound processing. A positive feedback mechanism within the cochlea, called the cochlear amplifier, provides amplitude and frequency selectivity in the mammalian auditory system. The cochlear amplifier and stability are studied using a nonlinear, micromechanical model of the Organ of Corti (OoC) coupled to the electrical potentials in the cochlear ducts. It is observed that the mechano-electrical transduction (MET) sensitivity and somatic motility of the outer hair cell (OHC), control the cochlear stability. Increasing MET sensitivity beyond a critical value, while electromechanical couplingmore » coefficient is within a specific range, causes instability. We show that instability in this model is generated through a supercritical Hopf bifurcation. A reduced order model of the system is approximated and it is shown that the tectorial membrane (TM) transverse mode effect on the dynamics is significant while the radial mode can be simplified from the equations. The cochlear amplifier in this model exhibits good agreement with the experimental data. A comprehensive 3-dimensional model based on the cross sectional model is simulated and the results are compared. It is indicated that the global model qualitatively inherits some characteristics of the local model, but the longitudinal coupling along the cochlea shifts the stability boundary (i.e., Hopf bifurcation point) and enhances stability.« less
Two-photon microscopy allows imaging and characterization of cochlear microvasculature in vivo.
Ihler, Friedrich; Bertlich, Mattis; Weiss, Bernhard; Dietzel, Steffen; Canis, Martin
2015-01-01
Impairment of cochlear blood flow has been discussed as factor in the pathophysiology of various inner ear disorders. However, the microscopic study of cochlear microcirculation is limited due to small scale and anatomical constraints. Here, two-photon fluorescence microscopy is applied to visualize cochlear microvessels. Guinea pigs were injected with Fluorescein isothiocyanate- or Texas red-dextrane as plasma marker. Intravital microscopy was performed in four animals and explanted cochleae from four animals were studied. The vascular architecture of the cochlea was visualized up to a depth of 90.0±22.7 μm. Imaging yielded a mean contrast-to-noise ratio (CNR) of 3.3±1.7. Mean diameter in vivo was 16.5±6.0 μm for arterioles and 8.0±2.4 μm for capillaries. In explanted cochleae, the diameter of radiating arterioles and capillaries was measured with 12.2±1.6 μm and 6.6±1.0 μm, respectively. The difference between capillaries and arterioles was statistically significant in both experimental setups (P<0.001 and P=0.022, two-way ANOVA). Measured vessel diameters in vivo and ex vivo were in agreement with published data. We conclude that two-photon fluorescence microscopy allows the investigation of cochlear microvessels and is potentially a valuable tool for inner ear research.
Use of a Parabolic Microphone to Detect Hidden Subjects in Search and Rescue.
Bowditch, Nathaniel L; Searing, Stanley K; Thomas, Jeffrey A; Thompson, Peggy K; Tubis, Jacqueline N; Bowditch, Sylvia P
2018-03-01
This study compares a parabolic microphone to unaided hearing in detecting and comprehending hidden callers at ranges of 322 to 2510 m. Eight subjects were placed 322 to 2510 m away from a central listening point. The subjects were concealed, and their calling volume was calibrated. In random order, subjects were asked to call the name of a state for 5 minutes. Listeners with parabolic microphones and others with unaided hearing recorded the direction of the call (detection) and name of the state (comprehension). The parabolic microphone was superior to unaided hearing in both detecting subjects and comprehending their calls, with an effect size (Cohen's d) of 1.58 for detection and 1.55 for comprehension. For each of the 8 hidden subjects, there were 24 detection attempts with the parabolic microphone and 54 to 60 attempts by unaided listeners. At the longer distances (1529-2510 m), the parabolic microphone was better at detecting callers (83% vs 51%; P<0.00001 by χ 2 ) and comprehension (57% vs 12%; P<0.00001). At the shorter distances (322-1190 m), the parabolic microphone offered advantages in detection (100% vs 83%; P=0.000023) and comprehension (86% vs 51%; P<0.00001), although not as pronounced as at the longer distances. Use of a 66-cm (26-inch) parabolic microphone significantly improved detection and comprehension of hidden calling subjects at distances between 322 and 2510 m when compared with unaided hearing. This study supports the use of a parabolic microphone in search and rescue to locate responsive subjects in favorable weather and terrain. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Effects of sustained release dexamethasone hydrogels in hearing preservation cochlear implantation.
Honeder, Clemens; Zhu, Chengjing; Schöpper, Hanna; Gausterer, Julia Clara; Walter, Manuel; Landegger, Lukas David; Saidov, Nodir; Riss, Dominik; Plasenzotti, Roberto; Gabor, Franz; Arnoldner, Christoph
2016-11-01
It has been shown that glucocorticoids reduce the hearing threshold shifts associated with cochlear implantation. Previous studies evaluated the administration of glucocorticoids immediately before surgery or the repeated pre- or perioperative systemic application of glucocorticoids. The aim of this study was to evaluate the effects of a sustained release dexamethasone hydrogel in hearing preservation cochlear implantation. To address this issue, a guinea pig model of cochlear implantation was used. 30 normal hearing pigmented guinea pigs were randomized into a group receiving a single dose of a dexamethasone/poloxamer407 hydrogel one day prior to surgery, a second group receiving the hydrogel seven days prior to surgery and a control group. A silicone cochlear implant electrode designed for the use in guinea pigs was inserted to a depth of 5 mm through a cochleostomy. Compound action potentials of the auditory nerve (frequency range 0.5-32 kHz) were measured preoperatively, directly postoperatively and on postoperative days 3, 7, 14, 21 and 28. Following the last audiometry, temporal bones were harvested and histologically evaluated. Dexamethasone hydrogel application one day prior to surgery resulted in significantly reduced hearing threshold shifts at low, middle and high frequencies measured at postoperative day 28 (p < 0.05). Application of the hydrogel seven days prior to surgery did not show such an effect. Dexamethasone application one day prior to surgery resulted in increased outer hair cell counts in the cochlear apex and in reduced spiral ganglion cell counts in the basal and middle turn of the cochlea, a finding that was associated with a higher rate of electrode translocation in this group. In this study, we were able to demonstrate functional benefits of a single preoperative intratympanic application of a sustained release dexamethasone hydrogel in a guinea pig model of cochlear implantation. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
High-temperature fiber-optic lever microphone
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J.; Cuomo, Frank W.; Nguyen, Trung D.; Rizzi, Stephen A.; Clevenson, Sherman A.
1995-01-01
The design and construction of a fiber-optic lever microphone, capable of operating continuously at temperatures up to 538 C (1000 F) are described. The design is based on the theoretical sensitivities of each of the microphone system components, namely, a cartridge containing a stretched membrane, an optical fiber probe, and an optoelectronic amplifier. Laboratory calibrations include the pistonphone sensitivity and harmonic distortion at ambient temperature, and frequency response, background noise, and optical power transmission at both ambient and elevated temperatures. A field test in the Thermal Acoustic Fatigue Apparatus at Langley Research Center, in which the microphone was subjected to overall sound-pressure levels in the range of 130-160 dB and at temperatures from ambient to 538 C, revealed good agreement with a standard probe microphone.
A directional microphone array for acoustic studies of wind tunnel models
NASA Technical Reports Server (NTRS)
Soderman, P. T.; Noble, S. C.
1974-01-01
An end-fire microphone array that utilizes a digital time delay system has been designed and evaluated for measuring noise in wind tunnels. The directional response of both a four- and eight-element linear array of microphones has enabled substantial rejection of background noise and reverberations in the NASA Ames 40- by 80-foot wind tunnel. In addition, it is estimated that four- and eight-element arrays reject 6 and 9 dB, respectively, of microphone wind noise, as compared with a conventional omnidirectional microphone with nose cone. Array response to two types of jet engine models in the wind tunnel is presented. Comparisons of array response to loudspeakers in the wind tunnel and in free field are made.
New Criteria of Indication and Selection of Patients to Cochlear Implant
Sampaio, André L. L.; Araújo, Mercêdes F. S.; Oliveira, Carlos A. C. P.
2011-01-01
Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant. PMID:22013448
Background noise in piezoresistive, electret condenser, and ceramic microphones.
Zuckerwar, Allan J; Kuhn, Theodore R; Serbyn, Roman M
2003-06-01
Background noise studies have been extended from air condenser microphones to piezoresistive, electret condenser, and ceramic microphones. Theoretical models of the respective noise sources within each microphone are developed and are used to derive analytical expressions for the noise power spectral density for each type. Several additional noise sources for the piezoresistive and electret microphones, beyond what had previously been considered, were applied to the models and were found to contribute significantly to the total noise power spectral density. Experimental background noise measurements were taken using an upgraded acoustic isolation vessel and data acquisition system, and the results were compared to the theoretically obtained expressions. The models were found to yield power spectral densities consistent with the experimental results. The measurements reveal that the 1/f noise coefficient is strongly correlated with the diaphragm damping resistance, irrespective of the detection technology, i.e., air condenser, piezoresistive, etc. This conclusion has profound implications upon the expected 1/f noise component of micromachined (MEMS) microphones.
The Effects of Linear Microphone Array Changes on Computed Sound Exposure Level Footprints
NASA Technical Reports Server (NTRS)
Mueller, Arnold W.; Wilson, Mark R.
1997-01-01
Airport land planning commissions often are faced with determining how much area around an airport is affected by the sound exposure levels (SELS) associated with helicopter operations. This paper presents a study of the effects changing the size and composition of a microphone array has on the computed SEL contour (ground footprint) areas used by such commissions. Descent flight acoustic data measured by a fifteen microphone array were reprocessed for five different combinations of microphones within this array. This resulted in data for six different arrays for which SEL contours were computed. The fifteen microphone array was defined as the 'baseline' array since it contained the greatest amount of data. The computations used a newly developed technique, the Acoustic Re-propagation Technique (ART), which uses parts of the NASA noise prediction program ROTONET. After the areas of the SEL contours were calculated the differences between the areas were determined. The area differences for the six arrays are presented that show a five and a three microphone array (with spacing typical of that required by the FAA FAR Part 36 noise certification procedure) compare well with the fifteen microphone array. All data were obtained from a database resulting from a joint project conducted by NASA and U.S. Army researchers at Langley and Ames Research Centers. A brief description of the joint project test design, microphone array set-up, and data reduction methodology associated with the database are discussed.
A low-cost acoustic permeameter
NASA Astrophysics Data System (ADS)
Drake, Stephen A.; Selker, John S.; Higgins, Chad W.
2017-04-01
Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, are fraught with sampling errors, and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. In this paper, we validate acoustically derived permeability of homogenous, reticulated foam samples by comparison with results derived using a standard flow-through permeameter. Acoustic permeameter elements were designed for use in snow, but the measurement methods are not snow-specific. The electronic components - consisting of a signal generator, amplifier, speaker, microphone, and oscilloscope - are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating, but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz, but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10-7 to 3 × 10-9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.
Salt, A N; Gill, R M; Hartsock, J J
2015-06-01
Understanding how drugs are distributed in perilymph following local applications is important as local drug therapies are increasingly used to treat disorders of the inner ear. The potential contribution of cerebrospinal fluid (CSF) entry to perilymph homeostasis has been controversial for over half a century, largely due to artifactual contamination of collected perilymph samples with CSF. Measures of perilymph flow and of drug distribution following round window niche applications have both suggested a slow, apically directed flow occurs along scala tympani (ST) in the normal, sealed cochlea. In the present study, we have used fluorescein isothiocyanate-dextran as a marker to study perilymph kinetics in guinea pigs. Dextran is lost from perilymph more slowly than other substances so far quantified. Dextran solutions were injected from pipettes sealed into the lateral semicircular canal (SCC), the cochlear apex, or the basal turn of ST. After varying delays, sequential perilymph samples were taken from the cochlear apex or lateral SCC, allowing dextran distribution along the perilymphatic spaces to be quantified. Variability was low and findings were consistent with the injection procedure driving volume flow towards the cochlear aqueduct, and with volume flow during perilymph sampling driven by CSF entry at the aqueduct. The decline of dextran with time in the period between injection and sampling was consistent with both a slow volume influx of CSF (~30 nL/min) entering the basal turn of ST at the cochlear aqueduct and a CSF-perilymph exchange driven by pressure-driven fluid oscillation across the cochlear aqueduct. Sample data also allowed contributions of other processes, such as communications with adjacent compartments, to be quantified. The study demonstrates that drug kinetics in the basal turn of ST is complex and is influenced by a considerable number of interacting processes.
Intracochlear Scala Media Pressure Measurement: Implications for Models of Cochlear Mechanics.
Kale, Sushrut S; Olson, Elizabeth S
2015-12-15
Models of the active cochlea build upon the underlying passive mechanics. Passive cochlear mechanics is based on physical and geometrical properties of the cochlea and the fluid-tissue interaction between the cochlear partition and the surrounding fluid. Although the fluid-tissue interaction between the basilar membrane and the fluid in scala tympani (ST) has been explored in both active and passive cochleae, there was no experimental data on the fluid-tissue interaction on the scala media (SM) side of the partition. To this aim, we measured sound-evoked intracochlear pressure in SM close to the partition using micropressure sensors. All the SM pressure data are from passive cochleae, likely because the SM cochleostomy led to loss of endocochlear potential. Thus, these experiments are studies of passive cochlear mechanics. SM pressure close to the tissue showed a pattern of peaks and notches, which could be explained as an interaction between fast and slow (i.e., traveling wave) pressure modes. In several animals SM and ST pressure were measured in the same cochlea. Similar to previous studies, ST-pressure was dominated by a slow, traveling wave mode at stimulus frequencies in the vicinity of the best frequency of the measurement location, and by a fast mode above best frequency. Antisymmetric pressure between SM and ST supported the classic single-partition cochlear models, or a dual-partition model with tight coupling between partitions. From the SM and ST pressure we calculated slow and fast modes, and from active ST pressure we extrapolated the passive findings to the active case. The passive slow mode estimated from SM and ST data was low-pass in nature, as predicted by cochlear models. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Intracochlear Scala Media Pressure Measurement: Implications for Models of Cochlear Mechanics
Kale, Sushrut S.; Olson, Elizabeth S.
2015-01-01
Models of the active cochlea build upon the underlying passive mechanics. Passive cochlear mechanics is based on physical and geometrical properties of the cochlea and the fluid-tissue interaction between the cochlear partition and the surrounding fluid. Although the fluid-tissue interaction between the basilar membrane and the fluid in scala tympani (ST) has been explored in both active and passive cochleae, there was no experimental data on the fluid-tissue interaction on the scala media (SM) side of the partition. To this aim, we measured sound-evoked intracochlear pressure in SM close to the partition using micropressure sensors. All the SM pressure data are from passive cochleae, likely because the SM cochleostomy led to loss of endocochlear potential. Thus, these experiments are studies of passive cochlear mechanics. SM pressure close to the tissue showed a pattern of peaks and notches, which could be explained as an interaction between fast and slow (i.e., traveling wave) pressure modes. In several animals SM and ST pressure were measured in the same cochlea. Similar to previous studies, ST-pressure was dominated by a slow, traveling wave mode at stimulus frequencies in the vicinity of the best frequency of the measurement location, and by a fast mode above best frequency. Antisymmetric pressure between SM and ST supported the classic single-partition cochlear models, or a dual-partition model with tight coupling between partitions. From the SM and ST pressure we calculated slow and fast modes, and from active ST pressure we extrapolated the passive findings to the active case. The passive slow mode estimated from SM and ST data was low-pass in nature, as predicted by cochlear models. PMID:26682824
Cozma, Romică Sebastian; Dima-Cozma, Lucia Corina; Rădulescu, Luminiţa Mihaela; Hera, Maria Cristina; Mârţu, Cristian; Olariu, Raluca; Cobzeanu, Bogdan Mihail; Bitere, Oana Roxana; Cobzeanu, Mihail Dan
2018-01-01
Patients with hearing loss who underwent cochlear implantation can present symptomatic or asymptomatic vestibular damages earlier or later after the surgery. The vestibular permanent lesions could be acute, produced by surgical trauma or could be progressive due to local morphological changes made by the presence of the portelectrode in the inner ear (fibrosis related, ossification, basilar membrane distortion, endolymphatic hydrops). Besides histopathological findings in inner ear of cochlear implanted patients, the vestibular permanent damages could be found by assessment of clinical vestibular status. This study reports the sensorial vestibular functional findings for adults in cochlear implanted ears related to the electrode insertion type (cochleostomy or round window approach) and comparing to non-implanted deaf ears. A total of 20 adult patients with 32 cochlear implanted ears (12 patients with binaural cochlear implant and eight with monoaural) were selected for postoperatory vestibular examination by cervical and ocular vestibular myogenic potentials and vestibular caloric tests. The same tests were made for a control group of 22 non-implanted deaf ears. Functional testing results were reported related to the electrode insertion approach. For the cochleostomy group, we found different deficits: in 40% for saccular function, 44% for utricular function, and 12% horizontal canal dysfunction. In round window group, the deficit was present in 14.29% for saccular function, 28.57% for utricular function, and 28.58% for horizontal canal. In 46.88% of implanted ears, the vestibular function was completely preserved on all tested sensors. In conclusion, the vestibular functional status after inner ear surgery presents sensorial damages in 53.12% ears compare with the vestibular dysfunction existing in 50% of deaf non-operated ears. Round window insertion allows for better conservation of the vestibular function.
Pneumococcal meningitis: development of a new animal model
Wei, Benjamin P.C.; Shepherd, Robert K.; Robins-Browne, Roy M.; Clark, Graeme M.; O’Leary, Stephen J.
2007-01-01
Hypothesis The rat is a suitable animal to establish a model for the study of pneumococcal meningitis post cochlear implantation Background There has been an increase in the number of cases of cochlear implant-related meningitis. The most common organism identified was Streptococcus pneumoniae. Whether cochlear implantation increases the risk of pneumococcal meningitis in healthy subjects without other risk factors remains to be determined. Previous animal studies do not focus on the pathogenesis and risk of pneumococcal meningitis post implantation and are based on relatively small animal numbers, making it difficult to assess the cause and effect relationship. There is, therefore, a need to develop a new animal model allowing direct examination of the pathogenesis of meningitis in the presence of a cochlear implant. Methods Eighteen non-implanted rats were infected with 1× 106 and 1 × 108 colony forming units (CFU) of a clinical isolate of S. pneumoniae via three different inoculation routes (middle ear, inner ear and intraperitoneal) to examine for evidence of meningitis over 24 hours. Six implanted rats were infected with the highest amount of bacteria possible for each route of inoculation (4 × 1010 CFU intraperitoneal, 3 × 108CFU middle ear, 1 × 106 CFU inner ear) to examine for evidence of meningitis with the presence of an implant. Histological pattern of cochlear infections for each of the three different inoculating routes were examined. Results Pneumococcal meningitis was evident in all 6 implanted animals for each of the three different routes of inoculation. Once in the inner ear, bacteria were found to enter the central nervous system either via the cochlear aqueduct or canaliculi perforantes of osseous spiral lamina, reaching the perineural and perivascular space then the internal acoustic meatus. The rate, extent and pattern of infection within the cochleae depended on the route of inoculation. Finally, there was no evidence of pneumococcal meningitis observed in 18 non-implanted rats inoculated at a lower concentration of S. pneumoniae when observed for 24 hours post-inoculation. Conclusion Meningitis in implanted rats following inoculation with a clinical isolate of S. pneumoniae is possible via all three potential routes of infection via the upper respiratory tract. The lack of meningitis observed in the 18 non-implanted rats suggests longer post-inoculation monitoring periods are required to ensure whether or not meningitis will develop. Based on this work we have developed a new animal model that will allow quantitative risk assessment of meningitis post cochlear implantation, and the assessment of the efficacy of potential interventional strategies in future studies. PMID:16936571
Microphone Phenomena Observed with EFL Students.
ERIC Educational Resources Information Center
Wilcox, Wilma B.
This study investigated changes in the speech patterns of Japanese college students in an intensive English language course when using a microphone, focusing in part on possible links to "karaoke" activities common in Japan, in which participants sing along with music using a microphone. The researcher first observed several karaoke…
Noise Attenuation Performance Assessment of the Joint Helmet Mounted Cueing System (JHMCS)
2010-08-01
Flash Drive (CFD) memory (Figure 9) and Sound Professionals SP-TFB-2 Miniature Binaural Microphones with the Sound Professionals SP-SPSB-1 Slim-line...flight noise. Sound Professionals binaural microphones were placed to record both internal and external sounds. One microphone was attached to the
A high-temperature wideband pressure transducer
NASA Technical Reports Server (NTRS)
Zuckerwar, A. J.
1975-01-01
Progress in the development of a pressure transducer for measurement of the pressure fluctuations in the high temperature environment of a jet exhaust is reported. A condenser microphone carrier system was adapted to meet the specifications. A theoretical analysis is presented which describes the operation of the condenser microphone in terms of geometry, materials, and other physical properties. The analysis was used as the basis for design of a prototype high temperature microphone. The feasibility of connecting the microphone to a converter over a high temperature cable operating as a half-wavelength transmission line was also examined.
Infrasonic Stethoscope for Monitoring Physiological Processes
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)
2018-01-01
An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.
Infrasonic Stethoscope for Monitoring Physiological Processes
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)
2016-01-01
An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.
Noise Robust Speech Recognition Applied to Voice-Driven Wheelchair
NASA Astrophysics Data System (ADS)
Sasou, Akira; Kojima, Hiroaki
2009-12-01
Conventional voice-driven wheelchairs usually employ headset microphones that are capable of achieving sufficient recognition accuracy, even in the presence of surrounding noise. However, such interfaces require users to wear sensors such as a headset microphone, which can be an impediment, especially for the hand disabled. Conversely, it is also well known that the speech recognition accuracy drastically degrades when the microphone is placed far from the user. In this paper, we develop a noise robust speech recognition system for a voice-driven wheelchair. This system can achieve almost the same recognition accuracy as the headset microphone without wearing sensors. We verified the effectiveness of our system in experiments in different environments, and confirmed that our system can achieve almost the same recognition accuracy as the headset microphone without wearing sensors.
Design of a hydrophone for an Ocean World lander
NASA Astrophysics Data System (ADS)
Smith, Heather D.; Duncan, Andrew G.
2017-10-01
For this presentation we describe the science return, and design of a microphone on- board a Europa lander mission. In addition to the E/PO benefit of a hydrophone to listen to the Europa Ocean, a microphone also provides scientific data on the properties of the subsurface ocean.A hydrophone is a small light-weight instrument that could be used to achieve two of the three Europa Lander mission anticipated science goals of: 1) Asses the habitability (particularly through quantitative compositional measurements of Europa via in situ techniques uniquely available to a landed mission. And 2) Characterize surface properties at the scale of the lander to support future exploration, including the local geologic context.Acoustic properties of the ocean would lead to a better understanding of the water density, currents, seafloor topography and other physical properties of the ocean as well as lead to an understanding of the salinity of the ocean. Sound from water movement (tidal movement, currents, subsurface out-gassing, ocean homogeneity (clines), sub-surface morphology, and biological sounds.The engineering design of the hydrophone instrument will be designed to fit within a portion of the resource allocation of the current best estimates of the Europa lander payload (26.6 Kg, 24,900 cm3, 2,500 W-hrs and 2700 Mbits). The hydrophone package will be designed to ensure planetary protection is maintained and will function under the cur- rent Europa lander mission operations scenario of a two-year cruise phase, and 30-day surface operational phase on Europa.Although the microphone could be used on the surface, it is designed to be lowered into the subsurface ocean. As such, planetary protection (forward contamination) is a primary challenge for a subsurface microphone/ camera. The preliminary design is based on the Navy COTS optical microphone.Reference: Pappalardo, R. T., et al. "Science potential from a Europa lander." Astrobiology 13.8 (2013): 740-773.
Yuldashev, Petr; Karzova, Maria; Khokhlova, Vera; Ollivier, Sébastien; Blanc-Benon, Philippe
2015-06-01
A Mach-Zehnder interferometer is used to measure spherically diverging N-waves in homogeneous air. An electrical spark source is used to generate high-amplitude (1800 Pa at 15 cm from the source) and short duration (50 μs) N-waves. Pressure waveforms are reconstructed from optical phase signals using an Abel-type inversion. It is shown that the interferometric method allows one to reach 0.4 μs of time resolution, which is 6 times better than the time resolution of a 1/8-in. condenser microphone (2.5 μs). Numerical modeling is used to validate the waveform reconstruction method. The waveform reconstruction method provides an error of less than 2% with respect to amplitude in the given experimental conditions. Optical measurement is used as a reference to calibrate a 1/8-in. condenser microphone. The frequency response function of the microphone is obtained by comparing the spectra of the waveforms resulting from optical and acoustical measurements. The optically measured pressure waveforms filtered with the microphone frequency response are in good agreement with the microphone output voltage. Therefore, an optical measurement method based on the Mach-Zehnder interferometer is a reliable tool to accurately characterize evolution of weak shock waves in air and to calibrate broadband acoustical microphones.
A three-microphone acoustic reflection technique using transmitted acoustic waves in the airway.
Fujimoto, Yuki; Huang, Jyongsu; Fukunaga, Toshiharu; Kato, Ryo; Higashino, Mari; Shinomiya, Shohei; Kitadate, Shoko; Takahara, Yutaka; Yamaya, Atsuyo; Saito, Masatoshi; Kobayashi, Makoto; Kojima, Koji; Oikawa, Taku; Nakagawa, Ken; Tsuchihara, Katsuma; Iguchi, Masaharu; Takahashi, Masakatsu; Mizuno, Shiro; Osanai, Kazuhiro; Toga, Hirohisa
2013-10-15
The acoustic reflection technique noninvasively measures airway cross-sectional area vs. distance functions and uses a wave tube with a constant cross-sectional area to separate incidental and reflected waves introduced into the mouth or nostril. The accuracy of estimated cross-sectional areas gets worse in the deeper distances due to the nature of marching algorithms, i.e., errors of the estimated areas in the closer distances accumulate to those in the further distances. Here we present a new technique of acoustic reflection from measuring transmitted acoustic waves in the airway with three microphones and without employing a wave tube. Using miniaturized microphones mounted on a catheter, we estimated reflection coefficients among the microphones and separated incidental and reflected waves. A model study showed that the estimated cross-sectional area vs. distance function was coincident with the conventional two-microphone method, and it did not change with altered cross-sectional areas at the microphone position, although the estimated cross-sectional areas are relative values to that at the microphone position. The pharyngeal cross-sectional areas including retropalatal and retroglossal regions and the closing site during sleep was visualized in patients with obstructive sleep apnea. The method can be applicable to larger or smaller bronchi to evaluate the airspace and function in these localized airways.
Factors influencing individual variation in perceptual directional microphone benefit.
Keidser, Gitte; Dillon, Harvey; Convery, Elizabeth; Mejia, Jorge
2013-01-01
Large variations in perceptual directional microphone benefit, which far exceed the variation expected from physical performance measures of directional microphones, have been reported in the literature. The cause for the individual variation has not been systematically investigated. To determine the factors that are responsible for the individual variation in reported perceptual directional benefit. A correlational study. Physical performance measures of the directional microphones obtained after they had been fitted to individuals, cognitive abilities of individuals, and measurement errors were related to perceptual directional benefit scores. Fifty-nine hearing-impaired adults with varied degrees of hearing loss participated in the study. All participants were bilaterally fitted with a Motion behind-the-ear device (500 M, 501 SX, or 501 P) from Siemens according to the National Acoustic Laboratories' non-linear prescription, version two (NAL-NL2). Using the Bamford-Kowal-Bench (BKB) sentences, the perceptual directional benefit was obtained as the difference in speech reception threshold measured in babble noise (SRTn) with the devices in directional (fixed hypercardioid) and in omnidirectional mode. The SRTn measurements were repeated three times with each microphone mode. Physical performance measures of the directional microphone included the angle of the microphone ports to loudspeaker axis, the frequency range dominated by amplified sound, the in situ signal-to-noise ratio (SNR), and the in situ three-dimensional, articulation-index weighted directivity index (3D AI-DI). The cognitive tests included auditory selective attention, speed of processing, and working memory. Intraparticipant variation on the repeated SRTn's and the interparticipant variation on the average SRTn were used to determine the effect of measurement error. A multiple regression analysis was used to determine the effect of other factors. Measurement errors explained 52% of the variation in perceptual directional microphone benefit (95% confidence interval [CI]: 34-78%), while another 37% of variation was explained primarily by the physical performance of the directional microphones after they were fitted to individuals. The most contributing factor was the in situ 3D AI-DI measured across the low frequencies. Repeated SRTn measurements are needed to obtain a reliable indication of the perceptual directional benefit in an individual. Further, to obtain optimum benefit from directional microphones, the effectiveness of the microphones should be maximized across the low frequencies. American Academy of Audiology.
Arrays of Miniature Microphones for Aeroacoustic Testing
NASA Technical Reports Server (NTRS)
Shams, Qamar A.; Humphreys, William M.; Sealey, Bradley S.; Bartram, Scott M.; Zuckewar, Allan J.; Comeaux, Toby; Adams, James K.
2007-01-01
A phased-array system comprised of custom-made and commercially available microelectromechanical system (MEMS) silicon microphones and custom ancillary hardware has been developed for use in aeroacoustic testing in hard-walled and acoustically treated wind tunnels. Recent advances in the areas of multi-channel signal processing and beam forming have driven the construction of phased arrays containing ever-greater numbers of microphones. Traditional obstacles to this trend have been posed by (1) the high costs of conventional condenser microphones, associated cabling, and support electronics and (2) the difficulty of mounting conventional microphones in the precise locations required for high-density arrays. The present development overcomes these obstacles. One of the hallmarks of the new system is a series of fabricated platforms on which multiple microphones can be mounted. These mounting platforms, consisting of flexible polyimide circuit-board material (see left side of figure), include all the necessary microphone power and signal interconnects. A single bus line connects all microphones to a common power supply, while the signal lines terminate in one or more data buses on the sides of the circuit board. To minimize cross talk between array channels, ground lines are interposed as shields between all the data bus signal lines. The MEMS microphones are electrically connected to the boards via solder pads that are built into the printed wiring. These flexible circuit boards share many characteristics with their traditional rigid counterparts, but can be manufactured much thinner, as small as 0.1 millimeter, and much lighter with boards weighing as much as 75 percent less than traditional rigid ones. For a typical hard-walled wind-tunnel installation, the flexible printed-circuit board is bonded to the tunnel wall and covered with a face sheet that contains precise cutouts for the microphones. Once the face sheet is mounted, a smooth surface is established over the entire array due to the flush mounting of all microphones (see right side of figure). The face sheet is made from a continuous glass-woven-fabric base impregnated with an epoxy resin binder. This material offers a combination of high mechanical strength and low dielectric loss, making it suitable for withstanding the harsh test section environment present in many wind tunnels, while at the same time protecting the underlying polyimide board. Customized signal-conditioning hardware consisting of line drivers and antialiasing filters are coupled with the array. The line drivers are constructed using low-supply-current, high-gain-bandwidth operational amplifiers designed to transmit the microphone signals several dozen feet from the array to external acquisition hardware. The anti-alias filters consist of individual Chebyshev low-pass filters (one for each microphone channel) housed on small printed-circuit boards mounted on one or more motherboards. The mother/daughter board design results in a modular system, which is easy to debug and service and which enables the filter characteristics to be changed by swapping daughter boards with ones containing different filter parameters. The filter outputs are passed to commercially- available acquisition hardware to digitize and store the conditioned microphone signals. Wind-tunnel testing of the new MEMS microphone polyimide mounting system shows that the array performance is comparable to that of traditional arrays, but with significantly less cost of construction.
Swept-sine noise-induced damage as a hearing loss model for preclinical assays
Sanz, Lorena; Murillo-Cuesta, Silvia; Cobo, Pedro; Cediel-Algovia, Rafael; Contreras, Julio; Rivera, Teresa; Varela-Nieto, Isabel; Avendaño, Carlos
2015-01-01
Mouse models are key tools for studying cochlear alterations in noise-induced hearing loss (NIHL) and for evaluating new therapies. Stimuli used to induce deafness in mice are usually white and octave band noises that include very low frequencies, considering the large mouse auditory range. We designed different sound stimuli, enriched in frequencies up to 20 kHz (“violet” noises) to examine their impact on hearing thresholds and cochlear cytoarchitecture after short exposure. In addition, we developed a cytocochleogram to quantitatively assess the ensuing structural degeneration and its functional correlation. Finally, we used this mouse model and cochleogram procedure to evaluate the potential therapeutic effect of transforming growth factor β1 (TGF-β1) inhibitors P17 and P144 on NIHL. CBA mice were exposed to violet swept-sine noise (VS) with different frequency ranges (2–20 or 9–13 kHz) and levels (105 or 120 dB SPL) for 30 min. Mice were evaluated by auditory brainstem response (ABR) and otoacoustic emission tests prior to and 2, 14 and 28 days after noise exposure. Cochlear pathology was assessed with gross histology; hair cell number was estimated by a stereological counting method. Our results indicate that functional and morphological changes induced by VS depend on the sound level and frequency composition. Partial hearing recovery followed the exposure to 105 dB SPL, whereas permanent cochlear damage resulted from the exposure to 120 dB SPL. Exposure to 9–13 kHz noise caused an auditory threshold shift (TS) in those frequencies that correlated with hair cell loss in the corresponding areas of the cochlea that were spotted on the cytocochleogram. In summary, we present mouse models of NIHL, which depending on the sound properties of the noise, cause different degrees of cochlear damage, and could therefore be used to study molecules which are potential players in hearing loss protection and repair. PMID:25762930
The Benefit of Remote Microphones Using Four Wireless Protocols.
Rodemerk, Krishna S; Galster, Jason A
2015-09-01
Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearing aids. As a result, commercial remote microphone systems use a variety of different protocols for wireless audio transmission. It is not known how these systems compare, with regard to adult speech recognition in noise. The primary goal of this investigation was to determine the speech recognition benefits of four different commercially available remote microphone systems, each with a different wireless audio transmission protocol. A repeated-measures design was used in this study. Sixteen adults, ages 52 to 81 yr, with mild to severe sensorineural hearing loss participated in this study. Participants were fit with three different sets of bilateral hearing aids and four commercially available remote microphone systems (FM, 900 MHz, 2.4 GHz, and Bluetooth(®) paired with near-field magnetic induction). Speech recognition scores were measured by an adaptive version of the Hearing in Noise Test (HINT). The participants were seated both 6 and 12' away from the talker loudspeaker. Participants repeated HINT sentences with and without hearing aids and with four commercially available remote microphone systems in both seated positions with and without contributions from the hearing aid or environmental microphone (24 total conditions). The HINT SNR-50, or the signal-to-noise ratio required for correct repetition of 50% of the sentences, was recorded for all conditions. A one-way repeated measures analysis of variance was used to determine statistical significance of microphone condition. The results of this study revealed that use of the remote microphone systems statistically improved speech recognition in noise relative to unaided and hearing aid-only conditions across all four wireless transmission protocols at 6 and 12' away from the talker. Participants showed a significant improvement in speech recognition in noise when comparing four remote microphone systems with different wireless transmission methods to hearing aids alone. American Academy of Audiology.
Kohlberg, Gavriel D; Mancuso, Dean M; Chari, Divya A; Lalwani, Anil K
2015-01-01
Enjoyment of music remains an elusive goal following cochlear implantation. We test the hypothesis that reengineering music to reduce its complexity can enhance the listening experience for the cochlear implant (CI) listener. Normal hearing (NH) adults (N = 16) and CI listeners (N = 9) evaluated a piece of country music on three enjoyment modalities: pleasantness, musicality, and naturalness. Participants listened to the original version along with 20 modified, less complex, versions created by including subsets of the musical instruments from the original song. NH participants listened to the segments both with and without CI simulation processing. Compared to the original song, modified versions containing only 1-3 instruments were less enjoyable to the NH listeners but more enjoyable to the CI listeners and the NH listeners with CI simulation. Excluding vocals and including rhythmic instruments improved enjoyment for NH listeners with CI simulation but made no difference for CI listeners. Reengineering a piece of music to reduce its complexity has the potential to enhance music enjoyment for the cochlear implantee. Thus, in addition to improvements in software and hardware, engineering music specifically for the CI listener may be an alternative means to enhance their listening experience.
Target structures in the cochlea for infrared neural stimulation (INS)
NASA Astrophysics Data System (ADS)
Young, Hunter; Tan, Xiaodong; Richter, Claus-Peter
2014-03-01
Spatial selective infrared neural stimulation has potential to improve neural prostheses, including cochlear implants. The heating of a confined target volume depolarizes the cell membrane and results in an action potential. Tissue heating may also result in the generation of a stress relaxation wave causing mechanical stimulation of hair cells in the cochlea, creating an optoacoustic response. Data are presented that quantify the effect of an acoustical stimulus (noise masker) on the response obtained with INS in normal hearing, and chronic deaf animals. While in normal hearing animals an acoustic masker can reduce the response to INS, in chronic deaf animals this effect has not been detected. The responses to INS remain stable following the different degrees of cochlear damage.
Assessment of a directional microphone array for hearing-impaired listeners.
Soede, W; Bilsen, F A; Berkhout, A J
1993-08-01
Hearing-impaired listeners often have great difficulty understanding speech in surroundings with background noise or reverberation. Based on array techniques, two microphone prototypes (broadside and endfire) have been developed with strongly directional characteristics [Soede et al., "Development of a new directional hearing instrument based on array technology," J. Acoust. Soc. Am. 94, 785-798 (1993)]. Physical measurements show that the arrays attenuate reverberant sound by 6 dB (free-field) and can improve the signal-to-noise ratio by 7 dB in a diffuse noise field (measured with a KEMAR manikin). For the clinical assessment of these microphones an experimental setup was made in a sound-insulated listening room with one loudspeaker in front of the listener simulating the partner in a discussion and eight loudspeakers placed on the edges of a cube producing a diffuse background noise. The hearing-impaired subject wearing his own (familiar) hearing aid is placed in the center of the cube. The speech-reception threshold in noise for simple Dutch sentences was determined with a normal single omnidirectional microphone and with one of the microphone arrays. The results of monaural listening tests with hearing impaired subjects show that in comparison with an omnidirectional hearing-aid microphone the broadside and endfire microphone array gives a mean improvement of the speech reception threshold in noise of 7.0 dB (26 subjects) and 6.8 dB (27 subjects), respectively. Binaural listening with two endfire microphone arrays gives a binaural improvement which is comparable to the binaural improvement obtained by listening with two normal ears or two conventional hearing aids.
ERIC Educational Resources Information Center
Clark, Catherine; Scott, Larry
This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…
49 CFR 325.33 - Site characteristics; highway operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... includes a portion of, a traveled lane of a public highway. A microphone target point shall be established on the centerline of the traveled lane of the highway, and a microphone location point shall be... microphone target point and on a line that is perpendicular to the centerline of the traveled lane of the...
Directional Microphone Hearing Aids in School Environments: Working toward Optimization
ERIC Educational Resources Information Center
Ricketts, Todd A.; Picou, Erin M.; Galster, Jason
2017-01-01
Purpose: The hearing aid microphone setting (omnidirectional or directional) can be selected manually or automatically. This study examined the percentage of time the microphone setting selected using each method was judged to provide the best signalto-noise ratio (SNR) for the talkers of interest in school environments. Method: A total of 26…
A high-temperature wideband pressure transducer
NASA Technical Reports Server (NTRS)
Zuckerwar, A. J.
1976-01-01
The problem of operating a condenser microphone as a terminal element of a half wavelength transmission line was dealt with; the environment in which the microphone operates necessitates a 25 foot separation from its supporting electronics. A theoretical analysis of the microphone-cable system, substantiated by laboratory tests, provided criteria to optimize system gain.
NASA Technical Reports Server (NTRS)
Sheplak, Mark (Inventor); Nishida, Toshikaza (Inventor); Humphreys, William M. (Inventor); Arnold, David P. (Inventor)
2006-01-01
Embodiments of the present invention described and shown in the specification aid drawings include a combination responsive to an acoustic wave that can be utilized as a dynamic pressure sensor. In one embodiment of the present invention, the combination has a substrate having a first surface and an opposite second surface, a microphone positioned on the first surface of the substrate and having an input and a first output and a second output, wherein the input receives a biased voltage, and the microphone generates an output signal responsive to the acoustic wave between the first output and the second output. The combination further has an amplifier positioned on the first surface of the substrate and having a first input and a second input and an output, wherein the first input of the amplifier is electrically coupled to the first output of the microphone and the second input of the amplifier is electrically coupled to the second output of the microphone for receiving the output sinual from the microphone. The amplifier is spaced from the microphone with a separation smaller than 0.5 mm.
Technique for measurement of characteristic impedance and propagation constant for porous materials
NASA Astrophysics Data System (ADS)
Jung, Ki Won; Atchley, Anthony A.
2005-09-01
Knowledge of acoustic properties such as characteristic impedance and complex propagation constant is useful to characterize the acoustic behaviors of porous materials. Song and Bolton's four-microphone method [J. Acoust. Soc. Am. 107, 1131-1152 (2000)] is one of the most widely employed techniques. In this method two microphones are used to determine the complex pressure amplitudes for each side of a sample. Muehleisen and Beamer [J. Acoust. Soc. Am. 117, 536-544 (2005)] improved upon a four-microphone method by interchanging microphones to reduce errors due to uncertainties in microphone response. In this paper, a multiple microphone technique is investigated to reconstruct the pressure field inside an impedance tube. Measurements of the acoustic properties of a material having square cross-section pores is used to check the validity of the technique. The values of characteristic impedance and complex propagation constant extracted from the reconstruction agree well with predicted values. Furthermore, this technique is used in investigating the acoustic properties of reticulated vitreous carbon (RVC) in the range of 250-1100 Hz.
Position-dependent patterning of spontaneous action potentials in immature cochlear inner hair cells
Johnson, Stuart L.; Eckrich, Tobias; Kuhn, Stephanie; Zampini, Valeria; Franz, Christoph; Ranatunga, Kishani M.; Roberts, Terri P.; Masetto, Sergio; Knipper, Marlies; Kros, Corné J.; Marcotti, Walter
2011-01-01
Spontaneous action potential activity is crucial for mammalian sensory system development. In the auditory system, patterned firing activity has been observed in immature spiral ganglion cells and brain-stem neurons and is likely to depend on cochlear inner hair cell (IHC) action potentials. It remains uncertain whether spiking activity is intrinsic to developing IHCs and whether it shows patterning. We found that action potentials are intrinsically generated by immature IHCs of altricial rodents and that apical IHCs exhibit bursting activity as opposed to more sustained firing in basal cells. We show that the efferent neurotransmitter ACh, by fine-tuning the IHC’s resting membrane potential (Vm), is crucial for the bursting pattern in apical cells. Endogenous extracellular ATP also contributes to the Vm of apical and basal IHCs by activating SK2 channels. We hypothesize that the difference in firing pattern along the cochlea instructs the tonotopic differentiation of IHCs and auditory pathway. PMID:21572434
Johnson, Stuart L; Eckrich, Tobias; Kuhn, Stephanie; Zampini, Valeria; Franz, Christoph; Ranatunga, Kishani M; Roberts, Terri P; Masetto, Sergio; Knipper, Marlies; Kros, Corné J; Marcotti, Walter
2011-06-01
Spontaneous action potential activity is crucial for mammalian sensory system development. In the auditory system, patterned firing activity has been observed in immature spiral ganglion and brain-stem neurons and is likely to depend on cochlear inner hair cell (IHC) action potentials. It remains uncertain whether spiking activity is intrinsic to developing IHCs and whether it shows patterning. We found that action potentials were intrinsically generated by immature IHCs of altricial rodents and that apical IHCs showed bursting activity as opposed to more sustained firing in basal cells. We show that the efferent neurotransmitter acetylcholine fine-tunes the IHC's resting membrane potential (V(m)), and as such is crucial for the bursting pattern in apical cells. Endogenous extracellular ATP also contributes to the V(m) of apical and basal IHCs by triggering small-conductance Ca(2+)-activated K(+) (SK2) channels. We propose that the difference in firing pattern along the cochlea instructs the tonotopic differentiation of IHCs and auditory pathway.
Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.
Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S
A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not observed for adults. An additional finding was that SMRT score was negatively correlated with age for adults with implants. Results from this study suggest that basic psychophysical capabilities of early implanted children and postlingually implanted adults differ when assessed in the sound field using their personal implant processors. Because spectral resolution does not improve with age for early implanted children, it seems likely that the sparse representation of the signal provided by a cochlear implant limits spectral resolution development. These results are supported by the finding that postlingually implanted adults, whose auditory systems matured before the onset of hearing loss, perform significantly better than early implanted children on the spectral resolution test.
Carraro, Mattia; Almishaal, Ali; Hillas, Elaine; Firpo, Matthew; Park, Albert; Harrison, Robert V
2017-04-01
Cytomegalovirus (CMV) infection is one of the most common causes of congenital hearing loss in children. We have used a murine model of CMV infection to reveal functional and structural cochlear pathogenesis. The cerebral cortex of Balb/c mice (Mus musculus) was inoculated with 2000 pfu (plaque forming units) of murine CMV on postnatal day 3. At 6 weeks of age, cochlear function was monitored using auditory brainstem response (ABR) and distortion product otoacoustic emission (DPOAE) measures. Histological assessment of cochlear vasculature using a corrosion cast technique was made at 8 weeks. Vascular casts of mCMV-damaged cochleas, and those of untreated control animals, were examined using scanning electron microscopy. We find very large variations in the degree of vascular damage in animals given identical viral injections (2000 pfu). The primary lesion caused by CMV infection is to the stria vascularis and to the adjacent spiral limbus capillary network. Capillary beds of the spiral ligament are generally less affected. The initial vascular damage is found in the mid-apical turn and appears to progress to more basal cochlear regions. After viral migration to the inner ear, the stria vascularis is the primary affected structure. We suggest that initial auditory threshold losses may relate to the poor development or maintenance of the endocochlear potential caused by strial dysfunction. Our increased understanding of the pathogenesis of CMV-related hearing loss is important for defining methods for early detection and treatment.
Kreft, Heather A.
2014-01-01
Under normal conditions, human speech is remarkably robust to degradation by noise and other distortions. However, people with hearing loss, including those with cochlear implants, often experience great difficulty in understanding speech in noisy environments. Recent work with normal-hearing listeners has shown that the amplitude fluctuations inherent in noise contribute strongly to the masking of speech. In contrast, this study shows that speech perception via a cochlear implant is unaffected by the inherent temporal fluctuations of noise. This qualitative difference between acoustic and electric auditory perception does not seem to be due to differences in underlying temporal acuity but can instead be explained by the poorer spectral resolution of cochlear implants, relative to the normally functioning ear, which leads to an effective smoothing of the inherent temporal-envelope fluctuations of noise. The outcome suggests an unexpected trade-off between the detrimental effects of poorer spectral resolution and the beneficial effects of a smoother noise temporal envelope. This trade-off provides an explanation for the long-standing puzzle of why strong correlations between speech understanding and spectral resolution have remained elusive. The results also provide a potential explanation for why cochlear-implant users and hearing-impaired listeners exhibit reduced or absent masking release when large and relatively slow temporal fluctuations are introduced in noise maskers. The multitone maskers used here may provide an effective new diagnostic tool for assessing functional hearing loss and reduced spectral resolution. PMID:25315376
Wolfe, Jace; Morais, Mila; Schafer, Erin
2016-02-01
The goals of the present investigation were (1) to evaluate recognition of recorded speech presented over a mobile telephone for a group of adult bimodal cochlear implant users, and (2) to measure the potential benefits of wireless hearing assistance technology (HAT) for mobile telephone speech recognition using bimodal stimulation (i.e., a cochlear implant in one ear and a hearing aid on the other ear). A three-by-two-way repeated measures design was used to evaluate mobile telephone sentence-recognition performance differences obtained in quiet and in noise with and without the wireless HAT accessory coupled to the hearing aid alone, CI sound processor alone, and in the bimodal condition. Outpatient cochlear implant clinic. Sixteen bimodal users with Nucleus 24, Freedom, CI512, or CI422 cochlear implants participated in this study. Performance was measured with and without the use of a wireless HAT for the telephone used with the hearing aid alone, CI alone, and bimodal condition. CNC word recognition in quiet and in noise with and without the use of a wireless HAT telephone accessory in the hearing aid alone, CI alone, and bimodal conditions. Results suggested that the bimodal condition gave significantly better speech recognition on the mobile telephone with the wireless HAT. A wireless HAT for the mobile telephone provides bimodal users with significant improvement in word recognition in quiet and in noise over the mobile telephone.
Hoshiba, Kotaro; Washizaki, Kai; Wakabayashi, Mizuho; Ishiki, Takahiro; Bando, Yoshiaki; Gabriel, Daniel; Nakadai, Kazuhiro; Okuno, Hiroshi G.
2017-01-01
In search and rescue activities, unmanned aerial vehicles (UAV) should exploit sound information to compensate for poor visual information. This paper describes the design and implementation of a UAV-embedded microphone array system for sound source localization in outdoor environments. Four critical development problems included water-resistance of the microphone array, efficiency in assembling, reliability of wireless communication, and sufficiency of visualization tools for operators. To solve these problems, we developed a spherical microphone array system (SMAS) consisting of a microphone array, a stable wireless network communication system, and intuitive visualization tools. The performance of SMAS was evaluated with simulated data and a demonstration in the field. Results confirmed that the SMAS provides highly accurate localization, water resistance, prompt assembly, stable wireless communication, and intuitive information for observers and operators. PMID:29099790
Hoshiba, Kotaro; Washizaki, Kai; Wakabayashi, Mizuho; Ishiki, Takahiro; Kumon, Makoto; Bando, Yoshiaki; Gabriel, Daniel; Nakadai, Kazuhiro; Okuno, Hiroshi G
2017-11-03
In search and rescue activities, unmanned aerial vehicles (UAV) should exploit sound information to compensate for poor visual information. This paper describes the design and implementation of a UAV-embedded microphone array system for sound source localization in outdoor environments. Four critical development problems included water-resistance of the microphone array, efficiency in assembling, reliability of wireless communication, and sufficiency of visualization tools for operators. To solve these problems, we developed a spherical microphone array system (SMAS) consisting of a microphone array, a stable wireless network communication system, and intuitive visualization tools. The performance of SMAS was evaluated with simulated data and a demonstration in the field. Results confirmed that the SMAS provides highly accurate localization, water resistance, prompt assembly, stable wireless communication, and intuitive information for observers and operators.
Sound source tracking device for telematic spatial sound field reproduction
NASA Astrophysics Data System (ADS)
Cardenas, Bruno
This research describes an algorithm that localizes sound sources for use in telematic applications. The localization algorithm is based on amplitude differences between various channels of a microphone array of directional shotgun microphones. The amplitude differences will be used to locate multiple performers and reproduce their voices, which were recorded at close distance with lavalier microphones, spatially corrected using a loudspeaker rendering system. In order to track multiple sound sources in parallel the information gained from the lavalier microphones will be utilized to estimate the signal-to-noise ratio between each performer and the concurrent performers.
NASA Astrophysics Data System (ADS)
Bicen, Baris
Measuring acoustic pressure gradients is critical in many applications such as directional microphones for hearing aids and sound intensity probes. This measurement is especially challenging with decreasing microphone size, which reduces the sensitivity due to small spacing between the pressure ports. Novel, micromachined biomimetic microphone diaphragms are shown to provide high sensitivity to pressure gradients on one side of the diaphragm with low thermal mechanical noise. These structures have a dominant mode shape with see-saw like motion in the audio band, responding to pressure gradients as well as spurious higher order modes sensitive to pressure. In this dissertation, integration of a diffraction based optical detection method with these novel diaphragm structures to implement a low noise optical pressure gradient microphone is described and experimental characterization results are presented, showing 36 dBA noise level with 1mm port spacing, nearly an order of magnitude better than the current gradient microphones. The optical detection scheme also provides electrostatic actuation capability from both sides of the diaphragm separately which can be used for active force feedback. A 4-port electromechanical equivalent circuit model of this microphone with optical readout is developed to predict the overall response of the device to different acoustic and electrostatic excitations. The model includes the damping due to complex motion of air around the microphone diaphragm, and it calculates the detected optical signal on each side of the diaphragm as a combination of two separate dominant vibration modes. This equivalent circuit model is verified by experiments and used to predict the microphone response with different force feedback schemes. Single sided force feedback is used for active damping to improve the linearity and the frequency response of the microphone. Furthermore, it is shown that using two sided force feedback one can significantly suppress or enhance the desired vibration modes of the diaphragm. This approach provides an electronic means to tailor the directional response of the microphones, with significant implications in device performance for various applications. As an example, the use of this device as a particle velocity sensor for sound intensity and sound power measurements is investigated. Without force feedback, the gradient microphone provides accurate particle velocity measurement for frequencies below 2 kHz, after which the pressure response of the second order mode becomes significant. With two-sided force feedback, the calculations show that this upper frequency limit may be increased to 10 kHz. This improves the pressure residual intensity index by more than 15 dB in the 50 Hz--10 kHz range, matching the Class I requirements of IEC 1043 standards for intensity probes without any need for multiple spacers.
Signal processing for the profoundly deaf.
Boothyroyd, A
1990-01-01
Profound deafness, defined here as a hearing loss in excess of 90 dB, is characterized by high thresholds, reduced hearing range in the intensity and frequency domains, and poor resolution in the frequency and time domains. The high thresholds call for hearing aids with unusually high gains or remote microphones that can be placed close to the signal source. The former option creates acoustic feedback problems for which digital signal processing may yet offer solutions. The latter option calls for carrier wave technology that is already available. The reduced frequency and intensity ranges would appear to call for frequency and/or amplitude compression. It might also be argued, however, that any attempts to compress the acoustic signal into the limited hearing range of the profoundly deaf will be counterproductive because of poor frequency and time resolution, especially when the signal is present in noise. In experiments with a 2-channel compression system, only 1 of 9 subjects showed an improvement of perception with the introduction of fast-release (20 ms) compression. The other 8 experienced no benefit or a slight deterioration of performance. These results support the concept of providing the profoundly deaf with simpler, rather than more complex, patterns, perhaps through the use of feature extraction hearing aids. Data from users of cochlear implants already employing feature extraction techniques also support this concept.
A circuit for detection of interaural time differences in the nucleus laminaris of turtles.
Willis, Katie L; Carr, Catherine E
2017-11-15
The physiological hearing range of turtles is approximately 50-1000 Hz, as determined by cochlear microphonics ( Wever and Vernon, 1956a). These low frequencies can constrain sound localization, particularly in red-eared slider turtles, which are freshwater turtles with small heads and isolated middle ears. To determine if these turtles were sensitive to interaural time differences (ITDs), we investigated the connections and physiology of their auditory brainstem nuclei. Tract tracing experiments showed that cranial nerve VIII bifurcated to terminate in the first-order nucleus magnocellularis (NM) and nucleus angularis (NA), and the NM projected bilaterally to the nucleus laminaris (NL). As the NL received inputs from each side, we developed an isolated head preparation to examine responses to binaural auditory stimulation. Magnocellularis and laminaris units responded to frequencies from 100 to 600 Hz, and phase-locked reliably to the auditory stimulus. Responses from the NL were binaural, and sensitive to ITD. Measures of characteristic delay revealed best ITDs around ±200 μs, and NL neurons typically had characteristic phases close to 0, consistent with binaural excitation. Thus, turtles encode ITDs within their physiological range, and their auditory brainstem nuclei have similar connections and cell types to other reptiles. © 2017. Published by The Company of Biologists Ltd.
[Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].
Zhang, Daoxcing; Zhang, Yankun
2006-02-01
Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.
What Does Music Sound Like for a Cochlear Implant User?
Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J
2017-09-01
Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-07
..., including the use of automated collection techniques or other forms of information technology, and (e) ways... Stations (Including Wireless Microphones). Form No.: N/A. Type of Review: Revision of a currently approved... wireless microphones and provide them a home in the core TV spectrum, where many wireless microphones are...
Uloza, Virgilijus; Padervinskis, Evaldas; Vegiene, Aurelija; Pribuisiene, Ruta; Saferis, Viktoras; Vaiciukynas, Evaldas; Gelzinis, Adas; Verikas, Antanas
2015-11-01
The objective of this study is to evaluate the reliability of acoustic voice parameters obtained using smart phone (SP) microphones and investigate the utility of use of SP voice recordings for voice screening. Voice samples of sustained vowel/a/obtained from 118 subjects (34 normal and 84 pathological voices) were recorded simultaneously through two microphones: oral AKG Perception 220 microphone and SP Samsung Galaxy Note3 microphone. Acoustic voice signal data were measured for fundamental frequency, jitter and shimmer, normalized noise energy (NNE), signal to noise ratio and harmonic to noise ratio using Dr. Speech software. Discriminant analysis-based Correct Classification Rate (CCR) and Random Forest Classifier (RFC) based Equal Error Rate (EER) were used to evaluate the feasibility of acoustic voice parameters classifying normal and pathological voice classes. Lithuanian version of Glottal Function Index (LT_GFI) questionnaire was utilized for self-assessment of the severity of voice disorder. The correlations of acoustic voice parameters obtained with two types of microphones were statistically significant and strong (r = 0.73-1.0) for the entire measurements. When classifying into normal/pathological voice classes, the Oral-NNE revealed the CCR of 73.7% and the pair of SP-NNE and SP-shimmer parameters revealed CCR of 79.5%. However, fusion of the results obtained from SP voice recordings and GFI data provided the CCR of 84.60% and RFC revealed the EER of 7.9%, respectively. In conclusion, measurements of acoustic voice parameters using SP microphone were shown to be reliable in clinical settings demonstrating high CCR and low EER when distinguishing normal and pathological voice classes, and validated the suitability of the SP microphone signal for the task of automatic voice analysis and screening.
Response to a pure tone in a nonlinear mechanical-electrical-acoustical model of the cochlea.
Meaud, Julien; Grosh, Karl
2012-03-21
In this article, a nonlinear mathematical model is developed based on the physiology of the cochlea of the guinea pig. The three-dimensional intracochlear fluid dynamics are coupled to a micromechanical model of the organ of Corti and to electrical potentials in the cochlear ducts and outer hair cells (OHC). OHC somatic electromotility is modeled by linearized piezoelectric relations whereas the OHC hair-bundle mechanoelectrical transduction current is modeled as a nonlinear function of the hair-bundle deflection. The steady-state response of the cochlea to a single tone is simulated in the frequency domain using an alternating frequency time scheme. Compressive nonlinearity, harmonic distortion, and DC shift on the basilar membrane (BM), tectorial membrane (TM), and OHC potentials are predicted using a single set of parameters. The predictions of the model are verified by comparing simulations to available in vivo experimental data for basal cochlear mechanics. In particular, the model predicts more amplification on the reticular lamina (RL) side of the cochlear partition than on the BM, which replicates recent measurements. Moreover, small harmonic distortion and DC shifts are predicted on the BM, whereas more significant harmonic distortion and DC shifts are predicted in the RL and TM displacements and in the OHC potentials. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.
System for determining aerodynamic imbalance
NASA Technical Reports Server (NTRS)
Churchill, Gary B. (Inventor); Cheung, Benny K. (Inventor)
1994-01-01
A system is provided for determining tracking error in a propeller or rotor driven aircraft by determining differences in the aerodynamic loading on the propeller or rotor blades of the aircraft. The system includes a microphone disposed relative to the blades during the rotation thereof so as to receive separate pressure pulses produced by each of the blades during the passage thereof by the microphone. A low pass filter filters the output signal produced by the microphone, the low pass filter having an upper cut-off frequency set below the frequency at which the blades pass by the microphone. A sensor produces an output signal after each complete revolution of the blades, and a recording display device displays the outputs of the low pass filter and sensor so as to enable evaluation of the relative magnitudes of the pressure pulses produced by passage of the blades by the microphone during each complete revolution of the blades.
Localization of sound sources in a room with one microphone
NASA Astrophysics Data System (ADS)
Peić Tukuljac, Helena; Lissek, Hervé; Vandergheynst, Pierre
2017-08-01
Estimation of the location of sound sources is usually done using microphone arrays. Such settings provide an environment where we know the difference between the received signals among different microphones in the terms of phase or attenuation, which enables localization of the sound sources. In our solution we exploit the properties of the room transfer function in order to localize a sound source inside a room with only one microphone. The shape of the room and the position of the microphone are assumed to be known. The design guidelines and limitations of the sensing matrix are given. Implementation is based on the sparsity in the terms of voxels in a room that are occupied by a source. What is especially interesting about our solution is that we provide localization of the sound sources not only in the horizontal plane, but in the terms of the 3D coordinates inside the room.
Optimization of a fiber optic flexible disk microphone
NASA Astrophysics Data System (ADS)
Zhang, Gang; Yu, Benli; Wang, Hui; Liu, Fei; Peng, Jun; Wu, Xuqiang
2011-11-01
An optimized design of a fiber optic flexible disk microphone is presented and verified experimentally. The phase sensitivity of optical fiber microphone (both the ideal model with a simply supported disk (SSD) and the model with a clamped disk (CLD)) is analyzed by utilizing theory of plates and shells. The results show that the microphones have an optimum length of the sensing arm when inner radius of the fiber coils, radius and Poisson's radio of the flexible disk have been determined. Under a typical condition depicted in this paper, an optimum phase sensitivity for SSD model of 27.72 rad/Pa (-91.14 dB re 1 rad/μPa) and an optimum phase sensitivity for CLD model of 3.18 rad/Pa (-109.95 dB re 1 rad/μPa), can be achieved in theory. Several sample microphones are fabricated and tested. The experimental results are basically consistent with the theoretical analysis.
In vivo evaluation of mastication noise reduction for dual channel implantable microphone.
Woo, SeongTak; Jung, EuiSung; Lim, HyungGyu; Lee, Jang Woo; Seong, Ki Woong; Won, Chul Ho; Kim, Myoung Nam; Cho, Jin Ho; Lee, Jyung Hyun
2014-01-01
Input for fully implantable hearing devices (FIHDs) is provided by an implantable microphone under the skin of the temporal bone. However, the implanted microphone can be affected when the FIHDs user chews. In this paper, a dual implantable microphone was designed that can filter out the noise from mastication. For the in vivo experiment, a fabricated microphone was implanted in a rabbit. Pure-tone sounds of 1 kHz through a standard speaker were applied to the rabbit, which was given food simultaneously. To evaluate noise reduction, the measured signals were processed using a MATLAB program based adaptive filter. To verify the proposed method, the correlation coefficients and signal to-noise ratio before and after signal processing were calculated. By comparing the results, signal-to-noise ratio and correlation coefficients are enhanced by 6.07dB and 0.529 respectively.
Effect of cochlear nerve electrocautery on the adult cochlear nucleus.
Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A
2015-04-01
Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.
High temperature sensor/microphone development for active noise control
NASA Technical Reports Server (NTRS)
Shrout, Thomas R.
1993-01-01
The industrial and scientific communities have shown genuine interest in electronic systems which can operate at high temperatures, among which are sensors to monitor noise, vibration, and acoustic emissions. Acoustic sensing can be accomplished by a wide variety of commercially available devices, including: simple piezoelectric sensors, accelerometers, strain gauges, proximity sensors, and fiber optics. Of the several sensing mechanisms investigated, piezoelectrics were found to be the most prevalent, because of their simplicity of design and application and, because of their high sensitivity over broad ranges of frequencies and temperature. Numerous piezoelectric materials are used in acoustic sensors today; but maximum use temperatures are imposed by their transition temperatures (T(sub c)) and by their resistivity. Lithium niobate, in single crystal form, has the highest operating temperature of any commercially available material, 650 C; but that is not high enough for future requirements. Only two piezoelectric materials show potential for use at 1000 C; AlN thin film reported to be piezoactive at 1150 C, and perovskite layer structure (PLS) materials, which possess among the highest T(sub c) (greater than 1500 C) reported for ferroelectrics. A ceramic PLS composition was chosen. The solid solution composition, 80% strontium niobate (SN) and 20% strontium tantalate (STa), with a T(sub c) approximately 1160 C, was hot forged, a process which concurrently sinters and renders the plate-like grains into a highly oriented configuration to enhance piezo properties. Poled samples of this composition showed coupling (k33) approximately 6 and piezoelectric strain constant (d33) approximately 3. Piezoactivity was seen at 1125 C, the highest temperature measurement reported for a ferroelectric ceramic. The high temperature piezoelectric responses of this, and similar PLS materials, opens the possibility of their use in electronic devices operating at temperatures up to 1000 C. Concurrent with the materials study was an effort to define issues involved in the development of a microphone capable of operation at temperatures up to 1000 C; important since microphones capable of operation above 260 C are not generally available. The distinguishing feature of a microphone is its diaphragm which receives sound from the atmosphere: whereas, most other acoustic sensors receive sound through the solid structure on which they are installed. In order to gain an understanding of the potential problems involved in designing and testing a high temperature microphone, a prototype was constructed using a commercially available lithium niobate piezoelectric element in a stainless steel structure. The prototype showed excellent frequency response at room temperature, and responded to acoustic stimulation at 670 C, above which temperature the voltage output rapidly diminished because of decreased resistivity in the element. Samples of the PLS material were also evaluated in a simulated microphone configuration, but their voltage output was found to be a few mV compared to the 10 output of the prototype.
Undersafe: Monitoring safety parameters in touristic mines and caves
NASA Astrophysics Data System (ADS)
Parcerisa, David; Sanmiquel, Lluís; Alfonso, Pura; Oliva, Josep
2014-05-01
Tourism is a key sector of the European economy, generating more than 5% of the EU GPD (Gross Domestic Product). Usually, underground touristic sites receive non-expert visitors; nevertheless these activities are poorly regulated or completely deregulated. Nowadays, safety is provided by underground expert professionals whom proceed to regular inspections and by basic safety infrastructures. Even with these measures, some potential personal and environmental dangers are always present and cannot be totally avoided. Therefore, there is a clear need of a new technological product for safety and environmental continuous monitoring of tourist underground attractions. So, the aim of the Undersafe project is to provide underground attractions with a novel and specifically tailored monitoring system, easy to use and maintain. One of the goals of the Undersafe project is to develop a rock falling detection based on a set of cost limited vibration sensors. Based on the technical needs, but with cost constraints, different types of potential sensors are considered: Underground microphone: It is placed in the surface or in the underground. It is based on the consideration that the impact of the stone generates a ground impact vibration which can be understood as a "noise" that is received by a microphone capsule. Airborne sound sensing microphone: It similarly applies to underground use of the microphones, but now the microphone is tested as for its traditional use (I.e. air sound detection). In such case, the microphone detects the environmental noise produced by the impact of the stone falling onto the ground, which will include the impact sound of the stone. Geophone: It is the de facto standard for ground vibrations. Although this technology was initially discarded due to its high cost, recently, low cost geophones have appeared in the market that allows its use inside the underground attractions. Accelerometers: These, can have enough sensibility to act as vibration sensors. Although the costs of the most sensible ones are out of the limits needed for our purposes, but some non-expensive accelerometers will be tested in real environment. All these systems have been tested and it can be concluded that results have been positive for the following technologies: piezoelectric, Electret (airborne and underground) and geophone. On the contrary, accelerometer and movement sensor provided negative results. The most sensible sensor that we have found is Electret that, in turn, is the most sensitive one to out of ground environmental noise (relevant in order to discard surface vibrations effect). All sensors can provide detections in a range of 15m. Low cost rock falling detectors, in cercles of 30 m of diameter are feasible. Also detection for longer distances, up to 80 meters, is feasible, but not advisable for low-cost application. Aknowledgements: Undersafe is an European project under the auspices of the EU 7h Framework Program. EDMA Innovation S.L. deeply contributed to the development of this study.
Hsiao, Feilin; Gfeller, Kate
2013-01-01
This review of literature presents a systematic analysis of the capabilities and limitations of cochlear implant recipients regarding music perception. Specifically, it a) analyzes individual components of music (e.g., rhythm, timbre, and pitch) as they interface with the technical characteristics of cochlear implants and the perceptual abilities of cochlear implant recipients; and b) describes accommodations for music instruction that support successful participation of children with cochlear implants. This article consolidates research studies from various disciplines (audiology, hearing science, speech-language pathology, cochlear implants, and music therapy) to provide practical recommendations for educators in fostering the musical growth of children with cochlear implants. PMID:23469365
Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.
Hassanzadeh, S
2012-10-01
This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.
Cochlear implant revision surgeries in children.
Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo
2018-02-16
The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Parental expectations and outcomes of pediatric cochlear implantation.
Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D
2009-10-01
Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... microphones and other low power auxiliary stations capable of operating in the core TV bands. 15.216 Section... wireless microphones and other low power auxiliary stations capable of operating in the core TV bands. (a... capable of operating in the core TV bands (channels 2-51, excluding channel 37) is subject to the...
Carbon granule probe microphone for leak detection. [recovery boilers
NASA Technical Reports Server (NTRS)
Parthasarathy, S. P. (Inventor)
1985-01-01
A microphone which is not subject to corrosion is provided by employing carbon granules to sense sound waves. The granules are packed into a ceramic tube and no diaphragm is used. A pair of electrodes is located in the tube adjacent the carbon granules and are coupled to a sensing circuit. Sound waves cause pressure changes on the carbon granules which results in a change in resistance in the electrical path between the electrodes. This change in resistance is detected by the sensing circuit. The microphone is suitable for use as a leak detection probe in recovery boilers, where it provides reliable operation without corrosion problems associated with conventional microphones.
Sound-field measurement with moving microphones
Katzberg, Fabrice; Mazur, Radoslaw; Maass, Marco; Koch, Philipp; Mertins, Alfred
2017-01-01
Closed-room scenarios are characterized by reverberation, which decreases the performance of applications such as hands-free teleconferencing and multichannel sound reproduction. However, exact knowledge of the sound field inside a volume of interest enables the compensation of room effects and allows for a performance improvement within a wide range of applications. The sampling of sound fields involves the measurement of spatially dependent room impulse responses, where the Nyquist-Shannon sampling theorem applies in the temporal and spatial domains. The spatial measurement often requires a huge number of sampling points and entails other difficulties, such as the need for exact calibration of a large number of microphones. In this paper, a method for measuring sound fields using moving microphones is presented. The number of microphones is customizable, allowing for a tradeoff between hardware effort and measurement time. The goal is to reconstruct room impulse responses on a regular grid from data acquired with microphones between grid positions, in general. For this, the sound field at equidistant positions is related to the measurements taken along the microphone trajectories via spatial interpolation. The benefits of using perfect sequences for excitation, a multigrid recovery, and the prospects for reconstruction by compressed sensing are presented. PMID:28599533
Tran, Phuong K; Letowski, Tomasz R; McBride, Maranda E
2013-06-01
Speech signals can be converted into electrical audio signals using either conventional air conduction (AC) microphone or a contact bone conduction (BC) microphone. The goal of this study was to investigate the effects of the location of a BC microphone on the intensity and frequency spectrum of the recorded speech. Twelve locations, 11 on the talker's head and 1 on the collar bone, were investigated. The speech sounds were three vowels (/u/, /a/, /i/) and two consonants (/m/, /∫/). The sounds were produced by 12 talkers. Each sound was recorded simultaneously with two BC microphones and an AC microphone. Analyzed spectral data showed that the BC recordings made at the forehead of the talker were the most similar to the AC recordings, whereas the collar bone recordings were most different. Comparison of the spectral data with speech intelligibility data collected in another study revealed a strong negative relationship between BC speech intelligibility and the degree of deviation of the BC speech spectrum from the AC spectrum. In addition, the head locations that resulted in the highest speech intelligibility were associated with the lowest output signals among all tested locations. Implications of these findings for BC communication are discussed.
Spatial channel interactions in cochlear implants
NASA Astrophysics Data System (ADS)
Tang, Qing; Benítez, Raul; Zeng, Fan-Gang
2011-08-01
The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal side. In contrast, the evoked compound action potential and perceptual channel interaction data showed much greater individual variability. It is likely that actual reduction in neural and higher level interactions, instead of simple sharpening of the electric current field, would be the key to predicting and hopefully improving the variable cochlear implant performance. The present results are obtained with auditory prostheses but can be applied to other neural prostheses, in which independent spatial channels, rather than a high stimulation rate, are critical to their performance.
Clinical application of neurotrophic factors: the potential for primary auditory neuron protection
Gillespie, Lisa N.; Shepherd, Robert K.
2007-01-01
Sensorineural hearing loss, as a result of damage to or destruction of the sensory epithelia within the cochlea, is a common cause of deafness. The subsequent degeneration of the neural elements within the inner ear may impinge upon the efficacy of the cochlear implant. Experimental studies have demonstrated that neurotrophic factors can prevent this degeneration in animal models of deafness, and can even provide functional benefits. Neurotrophic factor therapy may, therefore, provide similar protective effects in humans, resulting in improved speech perception outcomes among cochlear implant patients. There are, however, numerous issues pertaining to delivery techniques and treatment regimes which need to be addressed prior to any clinical application. This review considers these issues in view of the potential therapeutic application of neurotrophic factors within the auditory system. PMID:16262651
Bidirectional synaptic plasticity in the cerebellum-like mammalian dorsal cochlear nucleus
NASA Astrophysics Data System (ADS)
Fujino, Kiyohiro; Oertel, Donata
2003-01-01
The dorsal cochlear nucleus integrates acoustic with multimodal sensory inputs from widespread areas of the brain. Multimodal inputs are brought to spiny dendrites of fusiform and cartwheel cells in the molecular layer by parallel fibers through synapses that are subject to long-term potentiation and long-term depression. Acoustic cues are brought to smooth dendrites of fusiform cells in the deep layer by auditory nerve fibers through synapses that do not show plasticity. Plasticity requires Ca2+-induced Ca2+ release; its sensitivity to antagonists of N-methyl-D-aspartate and metabotropic glutamate receptors differs in fusiform and cartwheel cells.
Lichtenhan, J T; Hartsock, J; Dornhoffer, J R; Donovan, K M; Salt, A N
2016-11-01
Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. Copyright © 2016 Elsevier B.V. All rights reserved.
Lichtenhan, JT; Hartsock, J; Dornhoffer, JR; Donovan, KM; Salt, AN
2016-01-01
Background Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. New method Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Results Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Conclusions Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. PMID:27506463
Serotonin projection patterns to the cochlear nucleus.
Thompson, A M; Thompson, G C
2001-07-13
The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the dorsal cochlear nucleus, we concluded that the serotoninergic projection pattern to the cochlear nucleus is divergent and non-specific. Double-labeled fiber segments were also present, but sparse, in the superior olive, localized mainly in periolivary regions; this indicated that the divergence of dorsal and median raphe neurons that extends throughout regions of the cochlear nucleus also extended well beyond the cochlear nucleus to include at least the superior olivary complex as well.
Experience in cochlear reimplantation. Descriptive study of a 20-year period.
Gutiérrez-Salazar, Andrés; Cop, Constanze; Osorio-Acosta, Ángel; Borkoski-Barreiro, Silvia; Falcón-González, Juan C; Ramos-Macías, Ángel
2015-01-01
The cochlear implant is a surgical procedure that has increased substantially, because the paediatric population is diagnosed and implanted early and because there are increased potential indications. This device has the inherent risk of failure in performance, as dies any active medical device, which is the most common cause of implant removal. Our goal was to understand what the causes that produced removal in our series were, and confirm if these conformed to reality as reviewed in the literature. This was a retrospective, descriptive, observational study of 859 cochlear implant surgeries carried out between October 1991 and May 2011. The causes of implant removal were classified according to the European Consensus Statement on Cochlear Implant Failures and Explantations. The reimplantation rate was 6.16% (n=51). The most common reason for removal was technical device failure (45.5%), followed by infection/rejection (23.6%) and upgrade (12.7%). Less common causes: there were 3 cases (5.6%) of electrode misplacement, 2 cases (3.6%) of labyrinthine ossification, 2 (3.6%) as a result of head trauma, 2 (3.6%) from need for nuclear magnetic resonance imaging and 1 case (1.8%) from psychiatric illness. Cochlear reimplantation is a safe procedure, with a low complication rate. In our centre, it reaches an overall rate of 6.16%. Technical device failure remains the most common cause of this procedure, although there is a significant percentage of reimplantation for device update. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
VASS, Z.; DAI, C. F.; STEYGER, P. S.; JANCSÓ, G.; TRUNE, D. R.; NUTTALL, A. L.
2014-01-01
Evidence suggests that capsaicin-sensitive substance P (SP)-containing trigeminal ganglion neurons innervate the spiral modiolar artery (SMA), radiating arterioles, and the stria vascularis of the cochlea. Antidromic electrical or chemical stimulation of trigeminal sensory nerves results in neurogenic plasma extravasation in inner ear tissues. The primary aim of this study was to reveal the possible morphological basis of cochlear vascular changes mediated by capsaicin-sensitive sensory nerves. Therefore, the distribution of SP and capsaicin receptor (transient receptor potential vanilloid type 1—TRPV1) was investigated by double immunolabeling to demonstrate the anatomical relationships between the cochlear and vertebro-basilar blood vessels and the trigeminal sensory fiber system. Extensive TRPV1 and SP expression and co-localization were observed in axons within the adventitial layer of the basilar artery, the anterior inferior cerebellar artery, the SMA, and the radiating arterioles of the cochlea. There appears to be a functional relationship between the trigeminal ganglion and the cochlear blood vessels since electrical stimulation of the trigeminal ganglion induced significant plasma extravasation from the SMA and the radiating arterioles. The findings suggest that stimulation of paravascular afferent nerves may result in permeability changes in the basilar and cochlear vascular bed and may contribute to the mechanisms of vertebro-basilar type of headache through the release of SP and stimulation of TPVR1, respectively. We propose that vertigo, tinnitus, and hearing deficits associated with migraine may arise from perturbations of capsaicin-sensitive trigeminal sensory ganglion neurons projecting to the cochlea. PMID:15026132
Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Tsuji, Robinson Koji; Bento, Ricardo Ferreira; de Carvalho, Ana Claudia Martinho; Matas, Carla Gentile
2015-01-01
The purpose of this study was to longitudinally assess the behavioral and electrophysiological hearing changes of a girl inserted in a CI program, who had bilateral profound sensorineural hearing loss and underwent surgery of cochlear implantation with electrode activation at 21 months of age. She was evaluated using the P1 component of Long Latency Auditory Evoked Potential (LLAEP); speech perception tests of the Glendonald Auditory Screening Procedure (GASP); Infant Toddler Meaningful Auditory Integration Scale (IT-MAIS); and Meaningful Use of Speech Scales (MUSS). The study was conducted prior to activation and after three, nine, and 18 months of cochlear implant activation. The results of the LLAEP were compared with data from a hearing child matched by gender and chronological age. The results of the LLAEP of the child with cochlear implant showed gradual decrease in latency of the P1 component after auditory stimulation (172 ms–134 ms). In the GASP, IT-MAIS, and MUSS, gradual development of listening skills and oral language was observed. The values of the LLAEP of the hearing child were expected for chronological age (132 ms–128 ms). The use of different clinical instruments allow a better understanding of the auditory habilitation and rehabilitation process via CI. PMID:26881163
A surgical approach appropriate for targeted cochlear gene therapy in the mouse.
Jero, J; Tseng, C J; Mhatre, A N; Lalwani, A K
2001-01-01
Therapeutic manipulations of the mammalian cochlea, including cochlear gene transfer, have been predominantly studied using the guinea pig as the experimental model. With the significant developments in mouse genomics and the availability of mutant strains of mice with well-characterized hearing loss, the mouse justifiably will be the preferred animal model for therapeutic manipulations. However, the potential advantages of the mouse model have not been fully realized due to the surgical difficulty of accessing its small cochlea. This study describes a ventral approach, instead of the routinely used postauricular approach in other rodents, for accessing the mouse middle and inner ear, and its application in cochlear gene transfer. This ventral approach enabled rapid and direct delivery of liposome-transgene complex to the mouse inner ear while avoiding blood loss, facial nerve morbidity, and mortality. Transgene expression at 3 days was detected in Reissner's membrane, spiral limbus, spiral ligament, and spiral ganglion cells, in a pattern similar to that previously described in the guinea pig. The successful access and delivery of material to the mouse cochlea and the replication of gene expression seen in the guinea pig demonstrated in this study should promote the use of the mouse in future studies investigating targeted cochlear therapy.
Development of micro-electromechanical system (MEMS) cochlear biomodel
NASA Astrophysics Data System (ADS)
Ngelayang, Thailis Bounya Anak; Latif, Rhonira
2015-05-01
Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.
VEMP recording by binaural simultaneous stimulation in subjects with vestibulo-cochlear disorders.
Murofushi, Toshihisa; Takai, Yoshinari; Iwasaki, Shinichi; Matsuzaki, Masaki
2005-10-01
To reduce the testing time of vestibular evoked myogenic potentials (VEMP) and the physical efforts of subjects, we studied if VEMP recording by binaural simultaneous stimulation in patients with vestibulo-cochlear disorders can be applicable as a screening test. Twenty-eight patients with vestibulo-cochlear disorders (12 men and 16 women, 22 to 77 years of age) were enrolled in this study. Patients were presented with binaural or monaural click (95 dBnHL) stimulation to record VEMPs. Their VEMP responses to binaural simultaneous stimulation were compared with those of monaural individual stimulation. Twenty-six of the 28 patients (93%) showed the same results in binaural simultaneous stimulation as in monaural individual stimulation. Amplitudes of p13-n23 to binaural simultaneous stimulation showed significant correlation to those of monaural individual stimulation ( r =0.774, P <0.0001 t -test). Peak latencies of p13 and n23 of binaural simultaneous stimulation also showed significant correlation to those of monaural individual stimulation (p13: r =0.684, P <0.0001 t -test, n23: r =0.657, P <0.0001 t -test). The binaural simultaneous stimulation method for VEMP recording is applicable for patients with vestibulo-cochlear disorders as a screening test in the clinic.
Kohlberg, Gavriel D.; Mancuso, Dean M.; Chari, Divya A.; Lalwani, Anil K.
2015-01-01
Objective. Enjoyment of music remains an elusive goal following cochlear implantation. We test the hypothesis that reengineering music to reduce its complexity can enhance the listening experience for the cochlear implant (CI) listener. Methods. Normal hearing (NH) adults (N = 16) and CI listeners (N = 9) evaluated a piece of country music on three enjoyment modalities: pleasantness, musicality, and naturalness. Participants listened to the original version along with 20 modified, less complex, versions created by including subsets of the musical instruments from the original song. NH participants listened to the segments both with and without CI simulation processing. Results. Compared to the original song, modified versions containing only 1–3 instruments were less enjoyable to the NH listeners but more enjoyable to the CI listeners and the NH listeners with CI simulation. Excluding vocals and including rhythmic instruments improved enjoyment for NH listeners with CI simulation but made no difference for CI listeners. Conclusions. Reengineering a piece of music to reduce its complexity has the potential to enhance music enjoyment for the cochlear implantee. Thus, in addition to improvements in software and hardware, engineering music specifically for the CI listener may be an alternative means to enhance their listening experience. PMID:26543322
Development of micro-electromechanical system (MEMS) cochlear biomodel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ngelayang, Thailis Bounya Anak; Latif, Rhonira
Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. Inmore » this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.« less
Rosowski, John J; Bowers, Peter; Nakajima, Hideko H
2018-03-01
While most models of cochlear function assume the presence of only two windows into the mammalian cochlea (the oval and round windows), a position that is generally supported by several lines of data, there is evidence for additional sound paths into and out of the inner ear in normal mammals. In this report we review the existing evidence for and against the 'two-window' hypothesis. We then determine how existing data and inner-ear anatomy restrict transmission of sound through these additional sound pathways in cat by utilizing a well-tested model of the cat inner ear, together with anatomical descriptions of the cat cochlear and vestibular aqueducts (potential additional windows to the cochlea). We conclude: (1) The existing data place limits on the size of the cochlear and vestibular aqueducts in cat and are consistent with small volume-velocities through these ducts during ossicular stimulation of the cochlea, (2) the predicted volume velocities produced by aqueducts with diameters half the size of the bony diameters match the functional data within ±10 dB, and (3) these additional volume velocity paths contribute to the inner ear's response to non-acoustic stimulation and conductive pathology. Copyright © 2017 Elsevier B.V. All rights reserved.
Gaudrain, Etienne; Carlyon, Robert P
2013-01-01
Previous studies have suggested that cochlear implant users may have particular difficulties exploiting opportunities to glimpse clear segments of a target speech signal in the presence of a fluctuating masker. Although it has been proposed that this difficulty is associated with a deficit in linking the glimpsed segments across time, the details of this mechanism are yet to be explained. The present study introduces a method called Zebra-speech developed to investigate the relative contribution of simultaneous and sequential segregation mechanisms in concurrent speech perception, using a noise-band vocoder to simulate cochlear implants. One experiment showed that the saliency of the difference between the target and the masker is a key factor for Zebra-speech perception, as it is for sequential segregation. Furthermore, forward masking played little or no role, confirming that intelligibility was not limited by energetic masking but by across-time linkage abilities. In another experiment, a binaural cue was used to distinguish the target and the masker. It showed that the relative contribution of simultaneous and sequential segregation depended on the spectral resolution, with listeners relying more on sequential segregation when the spectral resolution was reduced. The potential of Zebra-speech as a segregation enhancement strategy for cochlear implants is discussed.
Gaudrain, Etienne; Carlyon, Robert P.
2013-01-01
Previous studies have suggested that cochlear implant users may have particular difficulties exploiting opportunities to glimpse clear segments of a target speech signal in the presence of a fluctuating masker. Although it has been proposed that this difficulty is associated with a deficit in linking the glimpsed segments across time, the details of this mechanism are yet to be explained. The present study introduces a method called Zebra-speech developed to investigate the relative contribution of simultaneous and sequential segregation mechanisms in concurrent speech perception, using a noise-band vocoder to simulate cochlear implants. One experiment showed that the saliency of the difference between the target and the masker is a key factor for Zebra-speech perception, as it is for sequential segregation. Furthermore, forward masking played little or no role, confirming that intelligibility was not limited by energetic masking but by across-time linkage abilities. In another experiment, a binaural cue was used to distinguish target and masker. It showed that the relative contribution of simultaneous and sequential segregation depended on the spectral resolution, with listeners relying more on sequential segregation when the spectral resolution was reduced. The potential of Zebra-speech as a segregation enhancement strategy for cochlear implants is discussed. PMID:23297922
Cochlear implantation in patients with bilateral cochlear trauma.
Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar
2010-01-01
Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.
Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn
2015-01-01
In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227
Improvement in cochlear flow with Pycnogenol® in patients with tinnitus: a pilot evaluation.
Grossi, M G; Belcaro, G; Cesarone, M R; Dugall, M; Hosoi, M; Cacchio, M; Ippolito, E; Bavera, P
2010-06-01
The aim of this preliminary evaluation was to study the efficacy of Pycnogenol in improving cochlear flow in patients with mild-to-moderate tinnitus present for at least two weeks (without vertigo or important hearing loss), possibly associated with cochlear hypo-perfusion. Patients with mild-to-moderate, idiopatic, monolateral tinnitus present for at least 2 weeks were included; no vertigo or important hearing loss had been found in a specific examination. The origin of tinnitus had been sudden (hours or days). Fifty-eight patients used Pycnogenol: 24 used 150 mg/day (group A; mean age 43.2+/-4.3) and 34 patients 100 mg/day (group B: mean age 42.4+/-3.8). Controls included 24 patients (mean age 42.3+/-4.5). The groups were comparable for their clinical problem and age and sex. The average duration of treatment was 34.3+/-3.1 days. No side effects were observed and no drop-outs occurred. The variations in cochlear flow velocity (in cm/s at the cochlear artery), at inclusion and after four weeks of treatment indicated that flow velocity at the level of the affected ear was significantly lower (both the diastolic and systolic components; P<0.05) in comparison with the other ear. The treatment favored an improvement in systolic (P<0.05) and diastolic flow velocity (P<0.05) in the two treatment groups A+B. The increase in flow velocity was very limited and not significant in controls. These results suggest that in selected patients with tinnitus and altered perfusion, Pycnogenol is effective in a short period of time in relieving tinnitus symptoms by improving cochlear blood flow. The effect is more pronounced with higher Pycnogenol dosage. More studies should be planned to better evaluate the pathology and potential applications of Pycnogenol in a larger number of patients who are currently without a real therapeutic solution.
Ultra-low-noise preamplifier for condenser microphones.
Starecki, Tomasz
2010-12-01
The paper presents the design of a low-noise preamplifier dedicated for condenser measurement microphones used in high sensitivity applications, in which amplifier noise is the main factor limiting sensitivity of the measurements. In measurement microphone preamplifiers, the dominant source of noise at lower frequencies is the bias resistance of the input stage. In the presented solution, resistors were connected to the input stage by means of switches. The switches are opened during measurements, which disconnects the resistors from the input stage and results in noise reduction. Closing the switches allows for fast charging of the microphone capacitance. At low frequencies the noise of the designed preamplifier is a few times lower in comparison to similar, commercially available instruments.
A four-element end-fire microphone array for acoustic measurements in wind tunnels
NASA Technical Reports Server (NTRS)
Soderman, P. T.; Noble, S. C.
1974-01-01
A prototype four-element end-fire microphone array was designed and built for evaluation as a directional acoustic receiver for use in large wind tunnels. The microphone signals were digitized, time delayed, summed, and reconverted to analog form in such a way as to create a directional response with the main lobe along the array axis. The measured array directivity agrees with theoretical predictions confirming the circuit design of the electronic control module. The array with 0.15 m (0.5 ft) microphone spacing rejected reverberations and background noise in the Ames 40- by 80-foot wind tunnel by 5 to 12 db for frequencies above 400 Hz.
Ma, R Y; Li, W; Jiang, X J
2016-12-01
Objective: To investigate the correlation between the site of prelingual cochlear stimulation and its effect on electrically evoked compound action potentials. Method: Recordings of auditory nerve responses were conducted in 32 prelingual subjects to demonstrate the feasibility of ECAP recordings using the nerve response telemetry(NRT) feature of the Nucleus CI24R(CA) system software. These recordings were then analyzed based on the site of cochlear stimulation defined as basal, middle and apical to determine if the amplitude, threshold and slope of the amplitude growth function and the refractory time differs depending on the region of stimulation. Result: Findings of our prelingual children showed significant differences in the ECAP recordings depending on the stimulation site. Comparing the apical with the basal region, on average higher amplitudes, lower thresholds and steeper slopes of the amplitude growth function hadbeen observed. The refractory time showed an overall dependence on cochlear region; however post-hoc tests showed no significant effect between individual regions. Conclusion: Obtaining ECAP recordings is also possible in the most apical region of the cochlea. However, differences can be observed depending on the region of the cochlea stimulated. Specifically, significant higher ECAP amplitude, lower thresholds and steeper amplitude growth function slopes have been observed in the apical region. These differences between prelingual children and adults could be explained by the location of the stimulating electrode with respect to the neural tissue in the cochlea, a higher density, or an increased neural survival rate of neural tissue in the apex. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
Digital Signal Processing in Acoustics--Part 2.
ERIC Educational Resources Information Center
Davies, H.; McNeill, D. J.
1986-01-01
Reviews the potential of a data acquisition system for illustrating the nature and significance of ideas in digital signal processing. Focuses on the fast Fourier transform and the utility of its two-channel format, emphasizing cross-correlation and its two-microphone technique of acoustic intensity measurement. Includes programing format. (ML)
DeVries, Lindsay; Scheperle, Rachel; Bierer, Julie Arenberg
2016-06-01
Variability in speech perception scores among cochlear implant listeners may largely reflect the variable efficacy of implant electrodes to convey stimulus information to the auditory nerve. In the present study, three metrics were applied to assess the quality of the electrode-neuron interface of individual cochlear implant channels: the electrically evoked compound action potential (ECAP), the estimation of electrode position using computerized tomography (CT), and behavioral thresholds using focused stimulation. The primary motivation of this approach is to evaluate the ECAP as a site-specific measure of the electrode-neuron interface in the context of two peripheral factors that likely contribute to degraded perception: large electrode-to-modiolus distance and reduced neural density. Ten unilaterally implanted adults with Advanced Bionics HiRes90k devices participated. ECAPs were elicited with monopolar stimulation within a forward-masking paradigm to construct channel interaction functions (CIF), behavioral thresholds were obtained with quadrupolar (sQP) stimulation, and data from imaging provided estimates of electrode-to-modiolus distance and scalar location (scala tympani (ST), intermediate, or scala vestibuli (SV)) for each electrode. The width of the ECAP CIF was positively correlated with electrode-to-modiolus distance; both of these measures were also influenced by scalar position. The ECAP peak amplitude was negatively correlated with behavioral thresholds. Moreover, subjects with low behavioral thresholds and large ECAP amplitudes, averaged across electrodes, tended to have higher speech perception scores. These results suggest a potential clinical role for the ECAP in the objective assessment of individual cochlear implant channels, with the potential to improve speech perception outcomes.
Glassman, E Katelyn; Hughes, Michelle L
2013-01-01
Current cochlear implants (CIs) have telemetry capabilities for measuring the electrically evoked compound action potential (ECAP). Neural Response Telemetry (Cochlear) and Neural Response Imaging (Advanced Bionics [AB]) can measure ECAP responses across a range of stimulus levels to obtain an amplitude growth function. Software-specific algorithms automatically mark the leading negative peak, N1, and the following positive peak/plateau, P2, and apply linear regression to estimate ECAP threshold. Alternatively, clinicians may apply expert judgments to modify the peak markers placed by the software algorithms, or use visual detection to identify the lowest level yielding a measurable ECAP response. The goals of this study were to: (1) assess the variability between human and computer decisions for (a) marking N1 and P2 and (b) determining linear-regression threshold (LRT) and visual-detection threshold (VDT); and (2) compare LRT and VDT methods within and across human- and computer-decision methods. ECAP amplitude-growth functions were measured for three electrodes in each of 20 ears (10 Cochlear Nucleus® 24RE/CI512, and 10 AB CII/90K). LRT, defined as the current level yielding an ECAP with zero amplitude, was calculated for both computer- (C-LRT) and human-picked peaks (H-LRT). VDT, defined as the lowest level resulting in a measurable ECAP response, was also calculated for both computer- (C-VDT) and human-picked peaks (H-VDT). Because Neural Response Imaging assigns peak markers to all waveforms but does not include waveforms with amplitudes less than 20 μV in its regression calculation, C-VDT for AB subjects was defined as the lowest current level yielding an amplitude of 20 μV or more. Overall, there were significant correlations between human and computer decisions for peak-marker placement, LRT, and VDT for both manufacturers (r = 0.78-1.00, p < 0.001). For Cochlear devices, LRT and VDT correlated equally well for both computer- and human-picked peaks (r = 0.98-0.99, p < 0.001), which likely reflects the well-defined Neural Response Telemetry algorithm and the lower noise floor in the 24RE and CI512 devices. For AB devices, correlations between LRT and VDT for both peak-picker methods were weaker than for Cochlear devices (r = 0.69-0.85, p < 0.001), which likely reflect the higher noise floor of the system. Disagreement between computer and human decisions regarding the presence of an ECAP response occurred for 5 % of traces for Cochlear devices and 2.1 % of traces for AB devices. Results indicate that human and computer peak-picking methods can be used with similar accuracy for both Cochlear and AB devices. Either C-VDT or C-LRT can be used with equal confidence for Cochlear 24RE and CI512 recipients because both methods are strongly correlated with human decisions. However, for AB devices, greater variability exists between different threshold-determination methods. This finding should be considered in the context of using ECAP measures to assist with programming CIs.
Free-field Calibration of the Pressure Sensitivity of Microphones at Frequencies up to 80 kHz
NASA Technical Reports Server (NTRS)
Herring, G. C.; Zuckerwar, Allan J.; Elbing, Brian R.
2006-01-01
A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the non-uniformity of the sound field and, as applied here, uses a 1/2 -inch air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that often plague FF measurements. Calibrations were performed on 1/4-inch FF air-condenser, electret, and micro-electromechanical systems (MEMS) microphones in an anechoic chamber. The accuracy of this FF method is estimated by comparing the pressure sensitivity of an air-condenser microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration and is typically 0.3 dB (95% confidence), over the range 2-80 kHz.
Contribution of crosstalk to the uncertainty of electrostatic actuator calibrations.
Shams, Qamar A; Soto, Hector L; Zuckerwar, Allan J
2009-09-01
Crosstalk in electrostatic actuator calibrations is defined as the ratio of the microphone response to the actuator excitation voltage at a given frequency with the actuator polarization voltage turned off to the response, at the excitation frequency, with the polarization voltage turned on. It consequently contributes to the uncertainty of electrostatic actuator calibrations. Two sources of crosstalk are analyzed: the first attributed to the stray capacitance between the actuator electrode and the microphone backplate, and the second to the ground resistance appearing as a common element in the actuator excitation and microphone input loops. Measurements conducted on 1/4, 1/2, and 1 in. air condenser microphones reveal that the crosstalk has no frequency dependence up to the membrane resonance frequency and that the level of crosstalk lies at about -60 dB for all three microphones-conclusions that are consistent with theory. The measurements support the stray capacitance model. The contribution of crosstalk to the measurement standard uncertainty of an electrostatic actuator calibration is therewith 0.01 dB.
Unvoiced Speech Recognition Using Tissue-Conductive Acoustic Sensor
NASA Astrophysics Data System (ADS)
Heracleous, Panikos; Kaino, Tomomi; Saruwatari, Hiroshi; Shikano, Kiyohiro
2006-12-01
We present the use of stethoscope and silicon NAM (nonaudible murmur) microphones in automatic speech recognition. NAM microphones are special acoustic sensors, which are attached behind the talker's ear and can capture not only normal (audible) speech, but also very quietly uttered speech (nonaudible murmur). As a result, NAM microphones can be applied in automatic speech recognition systems when privacy is desired in human-machine communication. Moreover, NAM microphones show robustness against noise and they might be used in special systems (speech recognition, speech transform, etc.) for sound-impaired people. Using adaptation techniques and a small amount of training data, we achieved for a 20 k dictation task a[InlineEquation not available: see fulltext.] word accuracy for nonaudible murmur recognition in a clean environment. In this paper, we also investigate nonaudible murmur recognition in noisy environments and the effect of the Lombard reflex on nonaudible murmur recognition. We also propose three methods to integrate audible speech and nonaudible murmur recognition using a stethoscope NAM microphone with very promising results.
Spatial acoustic radiation of respiratory sounds for sleep evaluation.
Shabtai, Noam R; Zigel, Yaniv
2017-09-01
Body posture has an effect on sleeping quality and breathing disorders and therefore it is important to be recognized for the completion of the sleep evaluation process. Since humans have a directional acoustic radiation pattern, it is hypothesized that microphone arrays can be used to recognize different body postures, which is highly practical for sleep evaluation applications that already measure respiratory sounds using distant microphones. Furthermore, body posture may have an effect on distant microphone measurement; hence, the measurement can be compensated if the body posture is correctly recognized. A spherical harmonics decomposition approach to the spatial acoustic radiation is presented, assuming an array of eight microphones in a medium-sized audiology booth. The spatial sampling and reconstruction of the radiation pattern is discussed, and a final setup for the microphone array is recommended. A case study is shown using recorded segments of snoring and breathing sounds of three human subjects in three body postures in a silent but not anechoic audiology booth.
Radiation impedance of condenser microphones and their diffuse-field responses.
Barrera-Figueroa, Salvador; Rasmussen, Knud; Jacobsen, Finn
2010-04-01
The relation between the diffuse-field response and the radiation impedance of a microphone has been investigated. Such a relation can be derived from classical theory. The practical measurement of the radiation impedance requires (a) measuring the volume velocity of the membrane of the microphone and (b) measuring the pressure on the membrane of the microphone. The first measurement is carried out by means of laser vibrometry. The second measurement cannot be implemented in practice. However, the pressure on the membrane can be calculated numerically by means of the boundary element method. In this way, a hybrid estimate of the radiation impedance is obtained. The resulting estimate of the diffuse-field response is compared with experimental estimates of the diffuse-field response determined using reciprocity and the random-incidence method. The different estimates are in good agreement at frequencies below the resonance frequency of the microphone. Although the method may not be of great practical utility, it provides a useful validation of the estimates obtained by other means.
An analytical-numerical method for determining the mechanical response of a condenser microphone
Homentcovschi, Dorel; Miles, Ronald N.
2011-01-01
The paper is based on determining the reaction pressure on the diaphragm of a condenser microphone by integrating numerically the frequency domain Stokes system describing the velocity and the pressure in the air domain beneath the diaphragm. Afterwards, the membrane displacement can be obtained analytically or numerically. The method is general and can be applied to any geometry of the backplate holes, slits, and backchamber. As examples, the method is applied to the Bruel & Kjaer (B&K) 4134 1/2-inch microphone determining the mechanical sensitivity and the mechano-thermal noise for a domain of frequencies and also the displacement field of the membrane for two specified frequencies. These elements compare well with the measured values published in the literature. Also a new design, completely micromachined (including the backvolume) of the B&K micro-electro-mechanical systems (MEM) 1/4-inch measurement microphone is proposed. It is shown that its mechanical performances are very similar to those of the B&K MEMS measurement microphone. PMID:22225026
An analytical-numerical method for determining the mechanical response of a condenser microphone.
Homentcovschi, Dorel; Miles, Ronald N
2011-12-01
The paper is based on determining the reaction pressure on the diaphragm of a condenser microphone by integrating numerically the frequency domain Stokes system describing the velocity and the pressure in the air domain beneath the diaphragm. Afterwards, the membrane displacement can be obtained analytically or numerically. The method is general and can be applied to any geometry of the backplate holes, slits, and backchamber. As examples, the method is applied to the Bruel & Kjaer (B&K) 4134 1/2-inch microphone determining the mechanical sensitivity and the mechano-thermal noise for a domain of frequencies and also the displacement field of the membrane for two specified frequencies. These elements compare well with the measured values published in the literature. Also a new design, completely micromachined (including the backvolume) of the B&K micro-electro-mechanical systems (MEM) 1/4-inch measurement microphone is proposed. It is shown that its mechanical performances are very similar to those of the B&K MEMS measurement microphone. © 2011 Acoustical Society of America
Adaptive Wiener filtering for improved acquisition of distortion product otoacoustic emissions.
Ozdamar, O; Delgado, R E; Rahman, S; Lopez, C
1998-01-01
An innovative acoustic noise canceling method using adaptive Wiener filtering (AWF) was developed for improved acquisition of distortion product otoacoustic emissions (DPOAEs). The system used one microphone placed in the test ear for the primary signal. Noise reference signals were obtained from three different sources: (a) pre-stimulus response from the test ear microphone, (b) post-stimulus response from a microphone placed near the head of the subject and (c) post-stimulus response obtained from a microphone placed in the subject's nontest ear. In order to improve spectral estimation, block averaging of a different number of single sweep responses was used. DPOAE data were obtained from 11 ears of healthy newborns in a well-baby nursery of a hospital under typical noise conditions. Simultaneously obtained recordings from all three microphones were digitized, stored and processed off-line to evaluate the effects of AWF with respect to DPOAE detection and signal-to-noise ratio (SNR) improvement. Results show that compared to standard DPOAE processing, AWF improved signal detection and improved SNR.
Development of an automated speech recognition interface for personal emergency response systems
Hamill, Melinda; Young, Vicky; Boger, Jennifer; Mihailidis, Alex
2009-01-01
Background Demands on long-term-care facilities are predicted to increase at an unprecedented rate as the baby boomer generation reaches retirement age. Aging-in-place (i.e. aging at home) is the desire of most seniors and is also a good option to reduce the burden on an over-stretched long-term-care system. Personal Emergency Response Systems (PERSs) help enable older adults to age-in-place by providing them with immediate access to emergency assistance. Traditionally they operate with push-button activators that connect the occupant via speaker-phone to a live emergency call-centre operator. If occupants do not wear the push button or cannot access the button, then the system is useless in the event of a fall or emergency. Additionally, a false alarm or failure to check-in at a regular interval will trigger a connection to a live operator, which can be unwanted and intrusive to the occupant. This paper describes the development and testing of an automated, hands-free, dialogue-based PERS prototype. Methods The prototype system was built using a ceiling mounted microphone array, an open-source automatic speech recognition engine, and a 'yes' and 'no' response dialog modelled after an existing call-centre protocol. Testing compared a single microphone versus a microphone array with nine adults in both noisy and quiet conditions. Dialogue testing was completed with four adults. Results and discussion The microphone array demonstrated improvement over the single microphone. In all cases, dialog testing resulted in the system reaching the correct decision about the kind of assistance the user was requesting. Further testing is required with elderly voices and under different noise conditions to ensure the appropriateness of the technology. Future developments include integration of the system with an emergency detection method as well as communication enhancement using features such as barge-in capability. Conclusion The use of an automated dialog-based PERS has the potential to provide users with more autonomy in decisions regarding their own health and more privacy in their own home. PMID:19583876
Current understanding of auditory neuropathy.
Boo, Nem-Yun
2008-12-01
Auditory neuropathy is defined by the presence of normal evoked otoacoustic emissions (OAE) and absent or abnormal auditory brainstem responses (ABR). The sites of lesion could be at the cochlear inner hair cells, spiral ganglion cells of the cochlea, synapse between the inner hair cells and auditory nerve, or the auditory nerve itself. Genetic, infectious or neonatal/perinatal insults are the 3 most commonly identified underlying causes. Children usually present with delay in speech and language development while adult patients present with hearing loss and disproportionately poor speech discrimination for the degree of hearing loss. Although cochlear implant is the treatment of choice, current evidence show that it benefits only those patients with endocochlear lesions, but not those with cochlear nerve deficiency or central nervous system disorders. As auditory neuropathy is a disorder with potential long-term impact on a child's development, early hearing screen using both OAE and ABR should be carried out on all newborns and infants to allow early detection and intervention.
A nonlinear cochlear model with the outer hair cell piezoelectric activity
NASA Astrophysics Data System (ADS)
Jiang, Xiaoai; Grosh, Karl
2003-10-01
In this paper we present a simple cochlear model which captures the most important aspect of nonlinearity in the cochlea-the nonlinearity caused by the piezoelectric-like activity of outer hair cells and the variable conductance of the outer hair cell stereocilia. A one-dimensional long-wave model is built to simulate the dynamic response of the fluid-loaded basilar membrane. The basilar membrane is simulated as isolated linear oscillators along the cochlear length, and its motion is coupled with the fluid pressure and the nonlinear force produced by the outer hair cells. As the basilar membrane moves, the fluid shears stereocilia, and the resulting ion flow changes the transmembrane potential of the outer hair cells and subsequently their length, leading to further movement of the basilar membrane. The piezoelectric-like activity of the outer hair cell is simulated by a current source, and stereocilia motion is modeled as a varying conductance that changes as the basilar membrane moves. A solution in the time domain will be presented. [Work supported by NIH.
TRPC1 is required for survival and proliferation of cochlear spiral ganglion stem/progenitor cells.
Chen, Hsin-Chien; Wang, Chih-Hung; Shih, Cheng-Ping; Chueh, Sheau-Huei; Liu, Shu-Fan; Chen, Hang-Kang; Lin, Yi-Chun
2015-12-01
The present studies were designed to test the hypothesis that canonical transient receptor potential channel 1 (TRPC1) is required for the proliferation of cochlear spiral ganglion stem/progenitor cells (SPCs). TRPC1 were detected and evaluated in postnatal day 1 CBA/CaJ mice pups derived-cochlear spiral ganglion SPCs by reverse transcription-polymerase chain reaction, Western blot, immunocytochemistry, and calcium imaging. The cell viability and proliferation of the spiral ganglion SPCs following si-RNA mediated knockdown of TRPC1 or addition of TRPC channel blocker SKF9635 were compared to controls. In spiral ganglion SPCs, TRPC1 was found to be the most abundantly expressed TRPC subunit and shown to contribute to store-operated calcium entry. Silencing of TRPC1 or addition of TRPC channel blockers significantly decreased the rate of cell proliferation. The results suggest that TRPC1 might serve as an essential molecule in regulating the proliferation of spiral ganglion SPCs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Cannabinoids, cannabinoid receptors and tinnitus.
Smith, Paul F; Zheng, Yiwen
2016-02-01
One hypothesis suggests that tinnitus is a form of sensory epilepsy, arising partly from neuronal hyperactivity in auditory regions of the brain such as the cochlear nucleus and inferior colliculus. Although there is currently no effective drug treatment for tinnitus, anti-epileptic drugs are used in some cases as a potential treatment option. There is increasing evidence to suggest that cannabinoid drugs, i.e. cannabinoid receptor agonists, can also have anti-epileptic effects, at least in some cases and in some parts of the brain. It has been reported that cannabinoid CB1 receptors and the endogenous cannabinoid, 2-arachidonylglycerol (2-AG), are expressed in the cochlear nucleus and that they are involved in the regulation of plasticity. This review explores the question of whether cannabinoid receptor agonists are likely to be pro- or anti-epileptic in the cochlear nucleus and therefore whether cannabinoids and Cannabis itself are likely to make tinnitus better or worse. Copyright © 2015 Elsevier B.V. All rights reserved.
A transmission-line model of back-cavity dynamics for in-plane pressure-differential microphones.
Kim, Donghwan; Kuntzman, Michael L; Hall, Neal A
2014-11-01
Pressure-differential microphones inspired by the hearing mechanism of a special parasitoid fly have been described previously. The designs employ a beam structure that rotates about two pivots over an enclosed back volume. The back volume is only partially enclosed due to open slits around the perimeter of the beam. The open slits enable incoming sound waves to affect the pressure profile in the microphone's back volume. The goal of this work is to study the net moment applied to pressure-differential microphones by an incoming sound wave, which in-turn requires modeling the acoustic pressure distribution within the back volume. A lumped-element distributed transmission-line model of the back volume is introduced for this purpose. It is discovered that the net applied moment follows a low-pass filter behavior such that, at frequencies below a corner frequency depending on geometrical parameters of the design, the applied moment is unaffected by the open slits. This is in contrast to the high-pass filter behavior introduced by barometric pressure vents in conventional omnidirectional microphones. The model accurately predicts observed curvature in the frequency response of a prototype pressure-differential microphone 2 mm × 1 mm × 0.5 mm in size and employing piezoelectric readout.
Vacuum-isolation vessel and method for measurement of thermal noise in microphones
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Ngo, Kim Chi T. (Inventor)
1992-01-01
The vacuum isolation vessel and method in accordance with the present invention are used to accurately measure thermal noise in microphones. The apparatus and method could be used in a microphone calibration facility or any facility used for testing microphones. Thermal noise is measured to determine the minimum detectable sound pressure by the microphone. Conventional isolation apparatus and methods have been unable to provide an acoustically quiet and substantially vibration free environment for accurately measuring thermal noise. In the present invention, an isolation vessel assembly comprises a vacuum sealed outer vessel, a vacuum sealed inner vessel, and an interior suspension assembly coupled between the outer and inner vessels for suspending the inner vessel within the outer vessel. A noise measurement system records thermal noise data from the isolation vessel assembly. A vacuum system creates a vacuum between an internal surface of the outer vessel and an external surface of the inner vessel. The present invention thus provides an acoustically quiet environment due to the vacuum created between the inner and outer vessels and a substantially vibration free environment due to the suspension assembly suspending the inner vessel within the outer vessel. The thermal noise in the microphone, effectively isolated according to the invention, can be accurately measured.
Ranjbar, Parivash; Stenström, Ingeborg
2013-01-01
Monitor is a portable vibrotactile aid to improve the ability of people with severe hearing impairment or deafblindness to detect, identify, and recognize the direction of sound-producing events. It transforms and adapts sounds to the frequency sensitivity range of the skin. The aid was evaluated in the field. Four females (44-54 years) with Usher Syndrome I (three with tunnel vision and one with only light perception) tested the aid at home and in traffic in three different field studies: without Monitor, with Monitor with an omnidirectional microphone, and with Monitor with a directional microphone. The tests were video-documented, and the two field studies with Monitor were initiated after five weeks of training. The detection scores with omnidirectional and directional microphones were 100% for three participants and above 57% for one, both in their home and traffic environments. In the home environment the identification scores with the omnidirectional microphone were 70%-97% and 58%-95% with the directional microphone. The corresponding values in traffic were 29%-100% and 65%-100%, respectively. Their direction perception was improved to some extent by both microphones. Monitor improved the ability of people with deafblindness to detect, identify, and recognize the direction of events producing sounds.
Recording high quality speech during tagged cine-MRI studies using a fiber optic microphone.
NessAiver, Moriel S; Stone, Maureen; Parthasarathy, Vijay; Kahana, Yuvi; Paritsky, Alexander; Paritsky, Alex
2006-01-01
To investigate the feasibility of obtaining high quality speech recordings during cine imaging of tongue movement using a fiber optic microphone. A Complementary Spatial Modulation of Magnetization (C-SPAMM) tagged cine sequence triggered by an electrocardiogram (ECG) simulator was used to image a volunteer while speaking the syllable pairs /a/-/u/, /i/-/u/, and the words "golly" and "Tamil" in sync with the imaging sequence. A noise-canceling, optical microphone was fastened approximately 1-2 inches above the mouth of the volunteer. The microphone was attached via optical fiber to a laptop computer, where the speech was sampled at 44.1 kHz. A reference recording of gradient activity with no speech was subtracted from target recordings. Good quality speech was discernible above the background gradient sound using the fiber optic microphone without reference subtraction. The audio waveform of gradient activity was extremely stable and reproducible. Subtraction of the reference gradient recording further reduced gradient noise by roughly 21 dB, resulting in exceptionally high quality speech waveforms. It is possible to obtain high quality speech recordings using an optical microphone even during exceptionally loud cine imaging sequences. This opens up the possibility of more elaborate MRI studies of speech including spectral analysis of the speech signal in all types of MRI.
Mistrík, Pavel; Mullaley, Chris; Mammano, Fabio; Ashmore, Jonathan
2009-03-06
The mammalian inner ear uses its sensory hair cells to detect and amplify incoming sound. It is unclear whether cochlear amplification arises uniquely from a voltage-dependent mechanism (electromotility) associated with outer hair cells (OHCs) or whether other mechanisms are necessary, for the voltage response of OHCs is apparently attenuated excessively by the membrane electrical filter. The cochlea contains many thousands of hair cells organized in extensive arrays, embedded in an electrically coupled system of supporting cells. We have therefore constructed a multi-element, large-scale computational model of cochlear sound transduction to study the underlying potassium (K+) recirculation. We have included experimentally determined parameters of cochlear macromechanics, which govern sound transduction, and data on hair cells' electrical parameters including tonotopical variation in the membrane conductance of OHCs. In agreement with the experiment, the model predicts an exponential decay of extracellular longitudinal K+ current spread. In contrast to the predictions from isolated cells, it also predicts low attenuation of the OHC transmembrane receptor potential (-5 dB per decade) in the 0.2-30 kHz range. This suggests that OHC electromotility could be driven by the transmembrane potential. Furthermore, the OHC electromotility could serve as a single amplification mechanism over the entire hearing range.
Cochlear implant in Hong Kong Cantonese.
Tang, S O; Luk, W S; Lau, C C; So, K W; Wong, C M; Yiu, M L; Kwok, C L
1990-11-01
Cochlear implant surgery was performed in four Cantonese-speaking postlingually deaf Chinese adults, using the House/3M single channel device. This article outlines the methodology, including preoperative assessment and postoperative rehabilitation; and explains the necessary modifications in speech and audiologic work-up in Cantonese-speaking patients. Salient features of Cantonese phonetics, especially its tonal characteristics, are described. The findings of the study are presented. The results of the cochlear implant would suggest a performance superior to that of the hearing aid. Furthermore, the cochlear implant is able to detect tonal cues. This quality of the cochlear implant may prove to be a valuable asset to a tonal language-speaking cochlear implantee.
Dai, Min; Nuttall, Alfred; Yang, Yue; Shi, Xiaorui
2009-08-01
Pericytes, mural cells located on microvessels, are considered to play an important role in the formation of the vasculature and the regulation of local blood flow in some organs. Little is known about the physiology of cochlear pericytes. In order to investigate the function of cochlear pericytes, we developed a method to visualize cochlear pericytes using diaminofluorescein-2 diacetate (DAF-2DA) and intravital fluorescence microscopy. This method can permit the study of the effect of vasoactive agents on pericytes under the in vivo and normal physiological condition. The specificity of the labeling method was verified by the immunofluorescence labeling of pericyte maker proteins such as desmin, neural proteoglycan (NG2), and thymocyte differentiation antigen 1 (Thy-1). Superfused K(+) and Ca(2+) to the cochlear lateral wall resulted in localized constriction of capillaries at pericyte locations both in vivo and in vitro, while there was no obvious change in cochlear capillary diameters with application of the adrenergic neurotransmitter noradrenaline. The method could be an effective way to visualize cochlear pericytes and microvessels and study lateral wall vascular physiology. Moreover, we demonstrate for the first time that cochlear pericytes have contractility, which may be important for regulation of cochlear blood flow.
Performance Analysis of a Cost-Effective Electret Condenser Microphone Directional Array
NASA Technical Reports Server (NTRS)
Humphreys, William M., Jr.; Gerhold, Carl H.; Zuckerwar, Allan J.; Herring, Gregory C.; Bartram, Scott M.
2003-01-01
Microphone directional array technology continues to be a critical part of the overall instrumentation suite for experimental aeroacoustics. Unfortunately, high sensor cost remains one of the limiting factors in the construction of very high-density arrays (i.e., arrays containing several hundred channels or more) which could be used to implement advanced beamforming algorithms. In an effort to reduce the implementation cost of such arrays, the authors have undertaken a systematic performance analysis of a prototype 35-microphone array populated with commercial electret condenser microphones. An ensemble of microphones coupling commercially available electret cartridges with passive signal conditioning circuitry was fabricated for use with the Langley Large Aperture Directional Array (LADA). A performance analysis consisting of three phases was then performed: (1) characterize the acoustic response of the microphones via laboratory testing and calibration, (2) evaluate the beamforming capability of the electret-based LADA using a series of independently controlled point sources in an anechoic environment, and (3) demonstrate the utility of an electret-based directional array in a real-world application, in this case a cold flow jet operating at high subsonic velocities. The results of the investigation revealed a microphone frequency response suitable for directional array use over a range of 250 Hz - 40 kHz, a successful beamforming evaluation using the electret-populated LADA to measure simple point sources at frequencies up to 20 kHz, and a successful demonstration using the array to measure noise generated by the cold flow jet. This paper presents an overview of the tests conducted along with sample data obtained from those tests.
Staisloff, Hannah E; Lee, Daniel H; Aronoff, Justin M
2016-07-01
For bilateral cochlear implant users, the left and right arrays are typically not physically aligned, resulting in a degradation of binaural fusion, which can be detrimental to binaural abilities. Perceptually aligning the two arrays can be accomplished by disabling electrodes in one ear that do not have a perceptually corresponding electrode in the other side. However, disabling electrodes at the edges of the array will cause compression of the input frequency range into a smaller cochlear extent, which may result in reduced spectral resolution. An alternative approach to overcome this mismatch would be to only align one edge of the array. By aligning either only the apical or basal end of the arrays, fewer electrodes would be disabled, potentially causing less reduction in spectral resolution. The goal of this study was to determine the relative effect of aligning either the basal or apical end of the electrode with regards to binaural fusion. A vocoder was used to simulate cochlear implant listening conditions in normal hearing listeners. Speech signals were vocoded such that the two ears were either predominantly aligned at only the basal or apical end of the simulated arrays. The experiment was then repeated with a spectrally inverted vocoder to determine whether the detrimental effects on fusion were related to the spectral-temporal characteristics of the stimuli or the location in the cochlea where the misalignment occurred. In Experiment 1, aligning the basal portion of the simulated arrays led to significantly less binaural fusion than aligning the apical portions of the simulated array. However, when the input was spectrally inverted, aligning the apical portion of the simulated array led to significantly less binaural fusion than aligning the basal portions of the simulated arrays. These results suggest that, for speech, with its predominantly low frequency spectral-temporal modulations, it is more important to perceptually align the apical portion of the array to better preserve binaural fusion. By partially aligning these arrays, cochlear implant users could potentially increase their ability to fuse speech sounds presented to the two ears while maximizing spectral resolution. Copyright © 2016 Elsevier B.V. All rights reserved.
Cochlear implants: system design, integration, and evaluation.
Zeng, Fan-Gang; Rebscher, Stephen; Harrison, William; Sun, Xiaoan; Feng, Haihong
2008-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
Sound-direction identification with bilateral cochlear implants.
Neuman, Arlene C; Haravon, Anita; Sislian, Nicole; Waltzman, Susan B
2007-02-01
The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. Eight adults who were bilateral users of Nucleus 24 Contour devices participated in the study. All had received implants in both ears in a single surgery. Sound-direction identification was measured in a large classroom by using a nine-loudspeaker array. Localization was tested in three listening conditions (bilateral cochlear implants, left cochlear implant, and right cochlear implant), using two different stimuli (a speech stimulus and pink noise bursts) in a repeated-measures design. Sound-direction identification accuracy was significantly better when using two implants than when using a single implant. The mean root-mean-square error was 29 degrees for the bilateral condition, 54 degrees for the left cochlear implant, and 46.5 degrees for the right cochlear implant condition. Unilateral accuracy was similar for right cochlear implant and left cochlear implant performance. Sound-direction identification performance was similar for speech and pink noise stimuli. The data obtained in this study add to the growing body of evidence that sound-direction identification with bilateral cochlear implants is better than with a single implant. The similarity in localization performance obtained with the speech and pink noise supports the use of either stimulus for measuring sound-direction identification.
Ozone Prevents Cochlear Damage From Ischemia-Reperfusion Injury in Guinea Pigs.
Onal, Merih; Elsurer, Cagdas; Selimoglu, Nebil; Yilmaz, Mustafa; Erdogan, Ender; Bengi Celik, Jale; Kal, Oznur; Onal, Ozkan
2017-08-01
The cochlea is an end organ, which is metabolically dependent on a nutrient and oxygen supply to maintain its normal physiological function. Cochlear ischemia and reperfusion (IR) injury is considered one of the most important causes of human idiopathic sudden sensorineural hearing loss. The aim of the present study was to study the efficacy of ozone therapy against cochlear damage caused by IR injury and to investigate the potential clinical use of this treatment for sudden deafness. Twenty-eight guinea pigs were randomized into four groups. The sham group (S) (n = 7) was administered physiological saline intraperitoneally (i.p.) for 7 days. The ozone group (O) (n = 7) was administered 1 mg/kg of ozone i.p. for 7 days. In the IR + O group (n = 7), 1 mg/kg of ozone was administered i.p. for 7 days before IR injury. On the eighth day, the IR + O group was subjected to cochlear ischemia for 15 min by occluding the bilateral vertebral artery and vein with a nontraumatic clamp and then reperfusion for 2 h. The IR group was subjected to cochlear IR injury. After the IR procedure, the guinea pigs were sacrificed on the same day. In a general histological evaluation, cochlear and spiral ganglionic tissues were examined with a light microscope, and apoptotic cells were counted by terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining. The apoptotic index (AI) was then calculated. Blood samples were sent for analyses of superoxide dismutase (SOD), glutathione peroxidase (GSH-Px), catalase, malondialdehyde (MDA), the total oxidant score (TOS), and total antioxidant capacity (TAC). Data were evaluated statistically using the Kruskal-Wallis test. The AI was highest in the IR group. The AI of the IR + O group was lower than that of the IR group. The biochemical antioxidant parameters SOD and GSH-Px and the TAC values were highest in the O group and lowest in the IR group. The MDA level and TOS were highest in the IR group and lowest in the O group. Controlled ozone administration stimulated endogenous antioxidant defense systems, thereby helping the body to combat IR injury. Although this study revealed a statistically significant decrease in cochlear IR damage following ozone therapy, further studies will be necessary to explain the protective mechanisms of ozone therapy in cochlear IR injury. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Fly-ear inspired acoustic sensors for gunshot localization
NASA Astrophysics Data System (ADS)
Liu, Haijun; Currano, Luke; Gee, Danny; Yang, Benjamin; Yu, Miao
2009-05-01
The supersensitive ears of the parasitoid fly Ormia ochracea have inspired researchers to develop bio-inspired directional microphone for sound localization. Although the fly ear is optimized for localizing the narrow-band calling song of crickets at 5 kHz, experiments and simulation have shown that it can amplify directional cues for a wide frequency range. In this article, a theoretical investigation is presented to study the use of fly-ear inspired directional microphones for gunshot localization. Using an equivalent 2-DOF model of the fly ear, the time responses of the fly ear structure to a typical shock wave are obtained and the associated time delay is estimated by using cross-correlation. Both near-field and far-field scenarios are considered. The simulation shows that the fly ear can greatly amplify the time delay by ~20 times, which indicates that with an interaural distance of only 1.2 mm the fly ear is able to generate a time delay comparable to that obtained by a conventional microphone pair with a separation as large as 24 mm. Since the parameters of the fly ear structure can also be tuned for muzzle blast and other impulse stimulus, fly-ear inspired acoustic sensors offers great potential for developing portable gunshot localization systems.
Morgenstern, Hai; Rafaely, Boaz; Zotter, Franz
2015-11-01
Spatial attributes of room acoustics have been widely studied using microphone and loudspeaker arrays. However, systems that combine both arrays, referred to as multiple-input multiple-output (MIMO) systems, have only been studied to a limited degree in this context. These systems can potentially provide a powerful tool for room acoustics analysis due to the ability to simultaneously control both arrays. This paper offers a theoretical framework for the spatial analysis of enclosed sound fields using a MIMO system comprising spherical loudspeaker and microphone arrays. A system transfer function is formulated in matrix form for free-field conditions, and its properties are studied using tools from linear algebra. The system is shown to have unit-rank, regardless of the array types, and its singular vectors are related to the directions of arrival and radiation at the microphone and loudspeaker arrays, respectively. The formulation is then generalized to apply to rooms, using an image source method. In this case, the rank of the system is related to the number of significant reflections. The paper ends with simulation studies, which support the developed theory, and with an extensive reflection analysis of a room impulse response, using the platform of a MIMO system.
Luo, Xin; Fu, Qian-Jie; Galvin, John J.
2007-01-01
The present study investigated the ability of normal-hearing listeners and cochlear implant users to recognize vocal emotions. Sentences were produced by 1 male and 1 female talker according to 5 target emotions: angry, anxious, happy, sad, and neutral. Overall amplitude differences between the stimuli were either preserved or normalized. In experiment 1, vocal emotion recognition was measured in normal-hearing and cochlear implant listeners; cochlear implant subjects were tested using their clinically assigned processors. When overall amplitude cues were preserved, normal-hearing listeners achieved near-perfect performance, whereas listeners with cochlear implant recognized less than half of the target emotions. Removing the overall amplitude cues significantly worsened mean normal-hearing and cochlear implant performance. In experiment 2, vocal emotion recognition was measured in listeners with cochlear implant as a function of the number of channels (from 1 to 8) and envelope filter cutoff frequency (50 vs 400 Hz) in experimental speech processors. In experiment 3, vocal emotion recognition was measured in normal-hearing listeners as a function of the number of channels (from 1 to 16) and envelope filter cutoff frequency (50 vs 500 Hz) in acoustic cochlear implant simulations. Results from experiments 2 and 3 showed that both cochlear implant and normal-hearing performance significantly improved as the number of channels or the envelope filter cutoff frequency was increased. The results suggest that spectral, temporal, and overall amplitude cues each contribute to vocal emotion recognition. The poorer cochlear implant performance is most likely attributable to the lack of salient pitch cues and the limited functional spectral resolution. PMID:18003871
Wireless microphone communication system telephonics P/N 484D000-1
NASA Technical Reports Server (NTRS)
1980-01-01
The wireless microphone is a lightweight, portable, wireless voice communications device for use by the crew of the space shuttle orbiter. The wireless microphone allows the crew to have normal hands-free voice communication while they are performing various mission activities. The unit is designed to transmit at 455 or 500 kilohertz and employs narrow band FM modulation. Two orthogonally placed antennas are used to insure good reception at the receiver.
Dynamically Reconfigurable Microphone Arrays
2011-05-01
from a number of different positions. In the second tests, the 2 wireless microphones were combined with a rigid binaural array on top of the b21r...Static + 2 Wireless Using only a standard computer sound card, a robot is limited to binaural inputs. Even when using wireless microphones, the audio...34 in HRI, Arlington, VA, 2007, pp. 113-120. [6] M. Heckmann, T. Rodemann, F. Joublin, C. Goerick, and B. Scholling, "Auditory Inspired Binaural
[Emotional response to music by postlingually-deafened adult cochlear implant users].
Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo
2012-10-01
To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.
The cochlear size of bats and rodents derived from MRI images and histology.
Hsiao, Chun Jen; Jen, Philip Hung-Sun; Wu, Chung Hsin
2015-05-27
From the evolutionary perspective, the ear of each animal species is built for effective processing of the biologically relevant signals used for communication and acoustically guided orientation. Because the sound pulses used by echolocating bats for orientation and rodents for communication are quite different, the basic design of the mammalian auditory system commonly shared by echolocating bats must be specialized in some manner to effectively process their species-specific sounds. The present study examines the difference in the cochlea of these animal species using MRI images and histological techniques. We report here that, although all these animal species share a similar cochlear structure, they vary in their cochlear size and turns. Bats using constant frequency-frequency-modulated pulses (CF-FM bats) and frequency-modulated pulses (FM bats) for echolocation have a larger cochlear size and more cochlear turns than rodents (mice and rats). However, CF-FM bats have the largest cochlear size and most cochlear turns. This difference in cochlear size and turns of these animal species is discussed in relation to their biologically relevant sounds and acoustic behavior.
Guideline on cochlear implants.
Manrique, Manuel; Ramos, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo, Elisa; Lassaleta, Luis; Sanchez-Cuadrado, Isabel; Espinosa, Juan Manuel; Batuecas, Ángel; Cenjor, Carlos; Lavilla, María José; Núñez, Faustino; Cavalle, Laura; Huarte, Alicia
2018-03-26
In the last decade numerous hospitals have started to work with patients who are candidates for a cochlear implant (CI) and there have been numerous and relevant advances in the treatment of sensorineural hearing loss that extended the indications for cochlear implants. To provide a guideline on cochlear implants to specialists in otorhinolaryngology, other medical specialities, health authorities and society in general. The Scientific Committees of Otology, Otoneurology and Audiology from the Spanish Society of Otolaryngology and Head and Neck Surgery (SEORL-CCC), in a coordinated and agreed way, performed a review of the current state of CI based on the existing regulations and in the scientific publications referenced in the bibliography of the document drafted. The clinical guideline on cochlear implants provides information on: a) Definition and description of Cochlear Implant; b) Indications for cochlear implants; c) Organizational requirements for a cochlear implant programme. A clinical guideline on cochlear implants has been developed by a Committee of Experts of the SEORL-CCC, to help and guide all the health professionals involved in this field of CI in decision-making to treathearing impairment. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.
Effect of shorter pulse duration in cochlear neural activation with an 810-nm near-infrared laser.
Wang, Jingxuan; Tian, Lan; Lu, Jianren; Xia, Ming; Wei, Ying
2017-02-01
Optical neural stimulation in the cochlea has been presented as an alternative technique to the electrical stimulation due to its potential in spatially selectivity enhancement. So far, few studies have selected the near-infrared (NIR) laser in cochlear neural stimulation and limited optical parameter space has been examined. This paper focused on investigating the optical parameter effect on NIR stimulation of auditory neurons, especially under shorter pulse durations. The spiral ganglion neurons in the cochlea of deafened guinea pigs were stimulated with a pulsed 810-nm NIR laser in vivo. The laser radiation was delivered by an optical fiber and irradiated towards the modiolus. Optically evoked auditory brainstem responses (OABRs) with various optical parameters were recorded and investigated. The OABRs could be elicited with the cochlear deafened animals by using the 810-nm laser in a wide pulse duration ranged from 20 to 1000 μs. Results showed that the OABR intensity increased along with the increasing laser radiant exposure of limited range at each specific pulse duration. In addition, for the pulse durations from 20 to 300 μs, the OABR intensity increased monotonically along with the pulse duration broadening. While for pulse durations above 300 μs, the OABR intensity basically kept stable with the increasing pulse duration. The 810-nm NIR laser could be an effective stimulus in evoking the cochlear neuron response. Our experimental data provided evidence to optimize the pulse duration range, and the results suggested that the pulse durations from 20 to 300 μs could be the optimized range in cochlear neural activation with the 810-nm-wavelength laser.
Glavaski-Joksimovic, Aleksandra; Thonabulsombat, Charoensri; Wendt, Malin; Eriksson, Mikael; Palmgren, Björn; Jonsson, Anna; Olivius, Petri
2008-03-01
The poor regeneration capability of the mammalian hearing organ has initiated different approaches to enhance its functionality after injury. To evaluate a potential neuronal repair paradigm in the inner ear and cochlear nerve we have previously used embryonic neuronal tissue and stem cells for implantation in vivo and in vitro. At present, we have used in vitro techniques to study the survival and differentiation of Sox1-green fluorescent protein (GFP) mouse embryonic stem (ES) cells as a monoculture or as a coculture with rat auditory brainstem slices. For the coculture, 300 microm-thick brainstem slices encompassing the cochlear nucleus and cochlear nerve were prepared from postnatal SD rats. The slices were propagated using the membrane interface method and the cochlear nuclei were prelabeled with DiI. After some days in culture a suspension of Sox1 cells was deposited next to the brainstem slice. Following deposition Sox1 cells migrated toward the brainstem and onto the cochlear nucleus. GFP was not detectable in undifferentiated ES cells but became evident during neural differentiation. Up to 2 weeks after transplantation the cocultures were fixed. The undifferentiated cells were evaluated with antibodies against progenitor cells whereas the differentiated cells were determined with neuronal and glial markers. The morphological and immunohistochemical data indicated that Sox1 cells in monoculture differentiated into a higher percentage of glial cells than neurons. However, when a coculture was used a significantly lower percentage of Sox1 cells differentiated into glial cells. The results demonstrate that a coculture of Sox1 cells and auditory brainstem present a useful model to study stem cell differentiation.
A novel perfusion-based method for cochlear implant electrode insertion.
Kale, Sushrut; Cervantes, Vanessa M; Wu, Mailing R; Pisano, Dominic V; Sheth, Nakul; Olson, Elizabeth S
2014-08-01
A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal turn. In the present study we report on the development of a new method to assist CI electrode insertion. The design objectives are (1) an automated and standardized insertion technique across patients with (2) more apical insertion than is possible by the contemporary methods, while (3) minimizing insertion trauma. The method relies on a viscous fluid flow through the cochlea to carry the electrode array with it. A small cochleostomy (∼100-150 um in diameter) is made in scala vestibuli (SV) and the round window (RW) membrane is opened. A flow of diluted Sodium Hyaluronate (also known as Hyaluronic Acid, (HA)) is set up from the RW to the SV opening using a perfusion pump that sets up a unidirectional flow. Once the flow is established an implant is dropped into the ongoing flow. Here we present a proof-of-concept study where we used this technique to insert silicone implants all the way to the cochlear apex in rats and gerbils. In light-microscopic histology, the implantation occurred without cochlear trauma. To further assess the ototoxicity of the HA perfusion, we measured compound action potential (CAP) thresholds following the perfusion of HA, and found that the CAP thresholds were substantially elevated. Thus, at this point the method is promising, and requires further development to become clinically viable. Copyright © 2014 Elsevier B.V. All rights reserved.
Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier
2015-02-01
Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.
Cochlear implants in children implanted in Jordan: A parental overview.
Alkhamra, Rana A
2015-07-01
Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (p<0.05). Despite the general satisfaction from the information quantity and quality prior to cochlear implant, parents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.
In vivo imaging of mammalian cochlear blood flow using fluorescence microendoscopy.
Monfared, Ashkan; Blevins, Nikolas H; Cheung, Eunice L M; Jung, Juergen C; Popelka, Gerald; Schnitzer, Mark J
2006-02-01
We sought to develop techniques for visualizing cochlear blood flow in live mammalian subjects using fluorescence microendoscopy. Inner ear microcirculation appears to be intimately involved in cochlear function. Blood velocity measurements suggest that intense sounds can alter cochlear blood flow. Disruption of cochlear blood flow may be a significant cause of hearing impairment, including sudden sensorineural hearing loss. However, inability to image cochlear blood flow in a nondestructive manner has limited investigation of the role of inner ear microcirculation in hearing function. Present techniques for imaging cochlear microcirculation using intravital light microscopy involve extensive perturbations to cochlear structure, precluding application in human patients. The few previous endoscopy studies of the cochlea have suffered from optical resolution insufficient for visualizing cochlear microvasculature. Fluorescence microendoscopy is an emerging minimally invasive imaging modality that provides micron-scale resolution in tissues inaccessible to light microscopy. In this article, we describe the use of fluorescence microendoscopy in live guinea pigs to image capillary blood flow and movements of individual red blood cells within the basal turn of the cochlea. We anesthetized eight adult guinea pigs and accessed the inner ear through the mastoid bulla. After intravenous injection of fluorescein dye, we made a limited cochleostomy and introduced a compound doublet gradient refractive index endoscope probe 1 mm in diameter into the inner ear. We then imaged cochlear blood flow within individual vessels in an epifluorescence configuration using one-photon fluorescence microendoscopy. We observed single red blood cells passing through individual capillaries in several cochlear structures, including the round window membrane, spiral ligament, osseous spiral lamina, and basilar membrane. Blood flow velocities within inner ear capillaries varied widely, with observed speeds reaching up to approximately 500 microm/s. Fluorescence microendoscopy permits visualization of cochlear microcirculation with micron-scale optical resolution and determination of blood flow velocities through analysis of video sequences.
Guianvarc'h, Cécile; Gavioso, Roberto M; Benedetto, Giuliana; Pitre, Laurent; Bruneau, Michel
2009-07-01
Condenser microphones are more commonly used and have been extensively modeled and characterized in air at ambient temperature and static pressure. However, several applications of interest for metrology and physical acoustics require to use these transducers in significantly different environmental conditions. Particularly, the extremely accurate determination of the speed of sound in monoatomic gases, which is pursued for a determination of the Boltzmann constant k by an acoustic method, entails the use of condenser microphones mounted within a spherical cavity, over a wide range of static pressures, at the temperature of the triple point of water (273.16 K). To further increase the accuracy achievable in this application, the microphone frequency response and its acoustic input impedance need to be precisely determined over the same static pressure and temperature range. Few previous works examined the influence of static pressure, temperature, and gas composition on the microphone's sensitivity. In this work, the results of relative calibrations of 1/4 in. condenser microphones obtained using an electrostatic actuator technique are presented. The calibrations are performed in pure helium and argon gas at temperatures near 273 K and in the pressure range between 10 and 600 kPa. These experimental results are compared with the predictions of a realistic model available in the literature, finding a remarkable good agreement. The model provides an estimate of the acoustic impedance of 1/4 in. condenser microphones as a function of frequency and static pressure and is used to calculate the corresponding frequency perturbations induced on the normal modes of a spherical cavity when this is filled with helium or argon gas.
Uncovering Spatial Variation in Acoustic Environments Using Sound Mapping.
Job, Jacob R; Myers, Kyle; Naghshineh, Koorosh; Gill, Sharon A
2016-01-01
Animals select and use habitats based on environmental features relevant to their ecology and behavior. For animals that use acoustic communication, the sound environment itself may be a critical feature, yet acoustic characteristics are not commonly measured when describing habitats and as a result, how habitats vary acoustically over space and time is poorly known. Such considerations are timely, given worldwide increases in anthropogenic noise combined with rapidly accumulating evidence that noise hampers the ability of animals to detect and interpret natural sounds. Here, we used microphone arrays to record the sound environment in three terrestrial habitats (forest, prairie, and urban) under ambient conditions and during experimental noise introductions. We mapped sound pressure levels (SPLs) over spatial scales relevant to diverse taxa to explore spatial variation in acoustic habitats and to evaluate the number of microphones needed within arrays to capture this variation under both ambient and noisy conditions. Even at small spatial scales and over relatively short time spans, SPLs varied considerably, especially in forest and urban habitats, suggesting that quantifying and mapping acoustic features could improve habitat descriptions. Subset maps based on input from 4, 8, 12 and 16 microphones differed slightly (< 2 dBA/pixel) from those based on full arrays of 24 microphones under ambient conditions across habitats. Map differences were more pronounced with noise introductions, particularly in forests; maps made from only 4-microphones differed more (> 4 dBA/pixel) from full maps than the remaining subset maps, but maps with input from eight microphones resulted in smaller differences. Thus, acoustic environments varied over small spatial scales and variation could be mapped with input from 4-8 microphones. Mapping sound in different environments will improve understanding of acoustic environments and allow us to explore the influence of spatial variation in sound on animal ecology and behavior.
The capture and recreation of 3D auditory scenes
NASA Astrophysics Data System (ADS)
Li, Zhiyun
The main goal of this research is to develop the theory and implement practical tools (in both software and hardware) for the capture and recreation of 3D auditory scenes. Our research is expected to have applications in virtual reality, telepresence, film, music, video games, auditory user interfaces, and sound-based surveillance. The first part of our research is concerned with sound capture via a spherical microphone array. The advantage of this array is that it can be steered into any 3D directions digitally with the same beampattern. We develop design methodologies to achieve flexible microphone layouts, optimal beampattern approximation and robustness constraint. We also design novel hemispherical and circular microphone array layouts for more spatially constrained auditory scenes. Using the captured audio, we then propose a unified and simple approach for recreating them by exploring the reciprocity principle that is satisfied between the two processes. Our approach makes the system easy to build, and practical. Using this approach, we can capture the 3D sound field by a spherical microphone array and recreate it using a spherical loudspeaker array, and ensure that the recreated sound field matches the recorded field up to a high order of spherical harmonics. For some regular or semi-regular microphone layouts, we design an efficient parallel implementation of the multi-directional spherical beamformer by using the rotational symmetries of the beampattern and of the spherical microphone array. This can be implemented in either software or hardware and easily adapted for other regular or semi-regular layouts of microphones. In addition, we extend this approach for headphone-based system. Design examples and simulation results are presented to verify our algorithms. Prototypes are built and tested in real-world auditory scenes.
Traversing Microphone Track Installed in NASA Lewis' Aero-Acoustic Propulsion Laboratory Dome
NASA Technical Reports Server (NTRS)
Bauman, Steven W.; Perusek, Gail P.
1999-01-01
The Aero-Acoustic Propulsion Laboratory is an acoustically treated, 65-ft-tall dome located at the NASA Lewis Research Center. Inside this laboratory is the Nozzle Acoustic Test Rig (NATR), which is used in support of Advanced Subsonics Technology (AST) and High Speed Research (HSR) to test engine exhaust nozzles for thrust and acoustic performance under simulated takeoff conditions. Acoustic measurements had been gathered by a far-field array of microphones located along the dome wall and 10-ft above the floor. Recently, it became desirable to collect acoustic data for engine certifications (as specified by the Federal Aviation Administration (FAA)) that would simulate the noise of an aircraft taking off as heard from an offset ground location. Since nozzles for the High-Speed Civil Transport have straight sides that cause their noise signature to vary radially, an additional plane of acoustic measurement was required. Desired was an arched array of 24 microphones, equally spaced from the nozzle and each other, in a 25 off-vertical plane. The various research requirements made this a challenging task. The microphones needed to be aimed at the nozzle accurately and held firmly in place during testing, but it was also essential that they be easily and routinely lowered to the floor for calibration and servicing. Once serviced, the microphones would have to be returned to their previous location near the ceiling. In addition, there could be no structure could between the microphones and the nozzle, and any structure near the microphones would have to be designed to minimize noise reflections. After many concepts were considered, a single arched truss structure was selected that would be permanently affixed to the dome ceiling and to one end of the dome floor.
Bruel and Kjaer 4944 Microphone Grid Frequency Response Function System Identification
NASA Technical Reports Server (NTRS)
Bennett, Reginald; Lee, Erik
2010-01-01
Br el & Kjaer (B&K) 4944B pressure field microphone was judiciously selected to measure acoustic environments, 400Hz 50kHz, in close proximity of the nozzle during multiple firings of solid propellant rocket motors. It is well known that protective grids can affect the frequency response of microphones. B&K recommends operation of the B&K 4944B without a protective grid when recording measurements above 10 to 15 kHz.
Mennill, Daniel J.; Burt, John M.; Fristrup, Kurt M.; Vehrencamp, Sandra L.
2008-01-01
A field test was conducted on the accuracy of an eight-microphone acoustic location system designed to triangulate the position of duetting rufous-and-white wrens (Thryothorus rufalbus) in Costa Rica’s humid evergreen forest. Eight microphones were set up in the breeding territories of twenty pairs of wrens, with an average inter-microphone distance of 75.2±2.6 m. The array of microphones was used to record antiphonal duets broadcast through stereo loudspeakers. The positions of the loudspeakers were then estimated by evaluating the delay with which the eight microphones recorded the broadcast sounds. Position estimates were compared to coordinates surveyed with a global-positioning system (GPS). The acoustic location system estimated the position of loudspeakers with an error of 2.82±0.26 m and calculated the distance between the “male” and “female” loudspeakers with an error of 2.12±0.42 m. Given the large range of distances between duetting birds, this relatively low level of error demonstrates that the acoustic location system is a useful tool for studying avian duets. Location error was influenced partly by the difficulties inherent in collecting high accuracy GPS coordinates of microphone positions underneath a lush tropical canopy, and partly by the complicating influence of irregular topography and thick vegetation on sound transmission. PMID:16708941
Colletti, V; Fiorino, F G
1993-11-01
To facilitate identification and preservation of the auditory nerve during cerebello-pontine angle surgery, bipolar recording of cochlear nerve compound action potentials (CNAPs) was performed. Two silver wires insulated with teflon up to the exposed ends were utilized as electrodes. They were twisted together, the distance between the two tips being 1 mm or less. Rarefaction polarity clicks (31/s) ranging from the psychoacoustical threshold to 120 dB pe SPL were used as stimuli. The investigation was performed in three groups of patients. The first group consisted of 9 patients submitted to vestibular neurectomy and 4 patients operated on by microvascular decompression of the eighth nerve. The second group comprised 8 patients with acoustic tumors smaller than 2 mm and serviceable hearing. Postoperative audiometric results in the subjects in the second group were compared with those obtained in well-matched homogeneous controls consisting of patients with acoustic neuroma operated on without the aid of CNAP recording. Bipolar recording from the eighth nerve was extremely selective, a good response being obtained only when positioning the electrode on the cochlear portion of the eighth nerve. During removal of the acoustic neuroma, repeated bipolar probing of the tumor and eighth nerve facilitated the task of distinguishing the cochlear nerve from other nervous structures and from the tumor, and contributed to preserving hearing in most patients.
Chen, Joshua Kuang-Chao; Chuang, Ann Yi-Chiun; McMahon, Catherine; Tung, Tao-Hsin; Li, Lieber Po-Hung
2014-09-01
Bimodal stimulation (BMS) has been shown to be beneficial for the performance of pitch ranking in postlingually deafened adults. However, the contribution of nonimplanted ears to pitch perception with respect to duration of hearing aid (HAs) use for prelingually cochlear implantees remained unclear. This study aimed to investigate whether experiences/duration of HAs use in the nonimplanted ear improved pitch perception ability in this population of subjects. Twenty-nine children with congenital/prelingual deafness of profound degree were studied. Test stimuli consisted of 2 sequential piano tones, ranging from C (256 Hz) to B (495 Hz). Children were asked to identify the pitch relationship between the 2 tones (i.e., same, higher, or lower). Duration of HAs use was the major factor related to the correct rate for pitch perception. Overall correct rate for pitch perception (O) could be best predicted by duration of HAs use (DuA) (O = 0.561XDuA, r = 0. 315, p = 0.002). Experiences of HAs use appear to improve pitch perception ability in prelingually cochlear implantees. This suggests that incorporation of HAs use early in life and through the postoperative rehabilitation program for prelingually deafened children with cochlear implants would be beneficial, although an association does not guarantee causality. A longitudinal study is needed to show whether improvement of music performance with duration of HAs use in these children is measurable using auditory evoked potentials.
Issues concerning international comparison of free-field calibrations of acoustical standards
NASA Astrophysics Data System (ADS)
Nedzelnitsky, Victor
2002-11-01
Primary free-field calibrations of laboratory standard microphones by the reciprocity method establish these microphones as reference standard devices for calibrating working standard microphones, other measuring microphones, and practical instruments such as sound level meters and personal sound exposure meters (noise dosimeters). These primary, secondary, and other calibrations are indispensable to the support of regulatory requirements, standards, and product characterization and quality control procedures important for industry, commerce, health, and safety. International Electrotechnical Commission (IEC) Technical Committee 29 Electroacoustics produces international documentary standards, including standards for primary and secondary free-field calibration and measurement procedures and their critically important application to practical instruments. This paper addresses some issues concerning calibrations, standards activities, and the international key comparison of primary free-field calibrations of IEC-type LS2 laboratory standard microphones that is being planned by the Consultative Committee for Acoustics, Ultrasound, and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM). This comparison will include free-field calibrations by the reciprocity method at participating major national metrology laboratories throughout the world.
Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.
Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan
2011-01-01
With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Real time aircraft fly-over noise discrimination
NASA Astrophysics Data System (ADS)
Genescà, M.; Romeu, J.; Pàmies, T.; Sánchez, A.
2009-06-01
A method for measuring aircraft noise time history with automatic elimination of simultaneous urban noise is presented in this paper. A 3 m-long 12-microphone sparse array has been proven to give good performance in a wide range of urban placements. Nowadays, urban placements have to be avoided because their background noise has a great influence on the measurements made by sound level meters or single microphones. Because of the small device size and low number of microphones (that make it so easy to set up), the resolution of the device is not high enough to provide a clean aircraft noise time history by only applying frequency domain beamforming to the spatial cross-correlations of the microphones' signals. Therefore, a new step to the processing algorithm has been added to eliminate this handicap.
Extreme Low Frequency Acoustic Measurement System
NASA Technical Reports Server (NTRS)
Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)
2017-01-01
The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.
Lumped-parameters equivalent circuit for condenser microphones modeling.
Esteves, Josué; Rufer, Libor; Ekeom, Didace; Basrour, Skandar
2017-10-01
This work presents a lumped parameters equivalent model of condenser microphone based on analogies between acoustic, mechanical, fluidic, and electrical domains. Parameters of the model were determined mainly through analytical relations and/or finite element method (FEM) simulations. Special attention was paid to the air gap modeling and to the use of proper boundary condition. Corresponding lumped-parameters were obtained as results of FEM simulations. Because of its simplicity, the model allows a fast simulation and is readily usable for microphone design. This work shows the validation of the equivalent circuit on three real cases of capacitive microphones, including both traditional and Micro-Electro-Mechanical Systems structures. In all cases, it has been demonstrated that the sensitivity and other related data obtained from the equivalent circuit are in very good agreement with available measurement data.
Extreme low frequency acoustic measurement system
NASA Technical Reports Server (NTRS)
Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)
2013-01-01
The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.
Auditory effects of aircraft noise on people living near an airport.
Chen, T J; Chen, S S; Hsieh, P Y; Chiang, H C
1997-01-01
Two groups of randomly chosen individuals who lived in two communities located different distances from the airport were studied. We monitored audiometry and brainstem auditory-evoked potentials to evaluate cochlear and retrocochlear functions in the individuals studied. The results of audiometry measurements indicated that hearing ability was reduced significantly in individuals who lived near the airport and who were exposed frequently to aircraft noise. Values of pure-tone average, high pure-tone average, and threshold at 4 kHz were all higher in individuals who lived near the airport, compared with those who lived farther away. With respect to brainstem auditory-evoked potentials, latencies between the two groups were not consistently different; however, the abnormality rate of such potentials was significantly higher in volunteers who lived near the airport, compared with less-exposed counterparts. In addition, a positive correlation was found between brainstem auditory-evoked potential latency and behavioral hearing threshold of high-frequency tone in exposed volunteers. We not only confirmed that damage to the peripheral cochlear organs occurred in individuals exposed frequently to aircraft noise, but we demonstrated involvement of the central auditory pathway.
Keefe, Douglas H.; Schairer, Kim S.
2011-01-01
An insert ear-canal probe including sound source and microphone can deliver a calibrated sound power level to the ear. The aural power absorbed is proportional to the product of mean-squared forward pressure, ear-canal area, and absorbance, in which the sound field is represented using forward (reverse) waves traveling toward (away from) the eardrum. Forward pressure is composed of incident pressure and its multiple internal reflections between eardrum and probe. Based on a database of measurements in normal-hearing adults from 0.22 to 8 kHz, the transfer-function level of forward relative to incident pressure is boosted below 0.7 kHz and within 4 dB above. The level of forward relative to total pressure is maximal close to 4 kHz with wide variability across ears. A spectrally flat incident-pressure level across frequency produces a nearly flat absorbed power level, in contrast to 19 dB changes in pressure level. Calibrating an ear-canal sound source based on absorbed power may be useful in audiological and research applications. Specifying the tip-to-tail level difference of the suppression tuning curve of stimulus frequency otoacoustic emissions in terms of absorbed power reveals increased cochlear gain at 8 kHz relative to the level difference measured using total pressure. PMID:21361437
Pinyon, Jeremy L; Tadros, Sherif F; Froud, Kristina E; Y Wong, Ann C; Tompson, Isabella T; Crawford, Edward N; Ko, Myungseo; Morris, Renée; Klugmann, Matthias; Housley, Gary D
2014-04-23
The cochlear implant is the most successful bionic prosthesis and has transformed the lives of people with profound hearing loss. However, the performance of the "bionic ear" is still largely constrained by the neural interface itself. Current spread inherent to broad monopolar stimulation of the spiral ganglion neuron somata obviates the intrinsic tonotopic mapping of the cochlear nerve. We show in the guinea pig that neurotrophin gene therapy integrated into the cochlear implant improves its performance by stimulating spiral ganglion neurite regeneration. We used the cochlear implant electrode array for novel "close-field" electroporation to transduce mesenchymal cells lining the cochlear perilymphatic canals with a naked complementary DNA gene construct driving expression of brain-derived neurotrophic factor (BDNF) and a green fluorescent protein (GFP) reporter. The focusing of electric fields by particular cochlear implant electrode configurations led to surprisingly efficient gene delivery to adjacent mesenchymal cells. The resulting BDNF expression stimulated regeneration of spiral ganglion neurites, which had atrophied 2 weeks after ototoxic treatment, in a bilateral sensorineural deafness model. In this model, delivery of a control GFP-only vector failed to restore neuron structure, with atrophied neurons indistinguishable from unimplanted cochleae. With BDNF therapy, the regenerated spiral ganglion neurites extended close to the cochlear implant electrodes, with localized ectopic branching. This neural remodeling enabled bipolar stimulation via the cochlear implant array, with low stimulus thresholds and expanded dynamic range of the cochlear nerve, determined via electrically evoked auditory brainstem responses. This development may broadly improve neural interfaces and extend molecular medicine applications.
Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M
2012-06-01
The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
[The development of musicality in children after cochlear implantation].
Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing
2014-08-01
The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (P<0.05). The mean scores of musicality also showed significant improvements with time for control group (P<0.05). There were no significant differences in mean scores between CI group and control group at 1, 3, 6, 9, 12 months of hearing age by rank sum test (P>0.05). Significant difference was noted between the two groups at 24 months (P<0.05). The musicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.
Cochlear Implants:System Design, Integration and Evaluation
Rebscher, Stephen; Harrison, William V.; Sun, Xiaoan; Feng, Haihong
2009-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120,000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues from design and specifications to integration and evaluation. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants. PMID:19946565
Li, Xu; Mao, Xiao-Bo; Hei, Ren-Yi; Zhang, Zhi-Bin; Wen, Li-Ting; Zhang, Peng-Zhi; Qiu, Jian-Hua; Qiao, Li
2011-01-01
A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL). The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2)S) has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2)S in cochlear blood flow regulation and noise protection. The gene and protein expression of the H(2)S synthetase cystathionine-γ-lyase (CSE) in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP), NaHS or DL-propargylglycine (PPG) were locally administered. Local sodium hydrosulfide (NaHS) significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR), cochlear scanning electron microscope (SEM) and outer hair cell (OHC) count. The highest percentage of OHC loss occurred in the PPG group. Our results suggest that H(2)S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.
Cochlear Patency After Transmastoid Labyrinthectomy for Ménière's Syndrome.
Sargent, Eric W; Liao, Eric; Gonda, Roger L
2016-08-01
Labyrinthectomy is considered the "gold standard" in the treatment of intractable vertigo attacks because of Ménière's Disease (MD) but sacrifices all residual hearing. Interest in auditory rehabilitation has lead to cochlear implantation in some patients. Concern remains that the cochlear lumen may fill with tissue or bone after surgery. This study sought to determine the incidence of obliteration of the cochlea after transmastoid labyrinthectomy. Retrospective observational study. Tertiary referral center. Eighteen patients with intractable vertigo from MD who underwent surgery. Transmastoid labyrinthectomy between 2008 and 2013. Cochleas were imaged with unenhanced, heavily T2-weighted magnetic resonance imaging (MRI). Presence of symmetrical cochlear fluid signals on MRI. There was no loss of fluid signal in the cochleas of operated ear compared with the contralateral, unoperated ear in any subject an average of 3 years (standard deviation [SD]: 1.2) after surgery. Five of 18 patients had the vestibule blocked with bone wax at the time of surgery. Blocking the vestibule with bone wax did not change the cochlear fluid signal. The risk of cochlear obstruction after labyrinthectomy for MD is very low. The significance of this finding is that patients with MD who undergo labyrinthectomy will likely remain candidates for cochlear implantation in the labyrinthectomized ear long after surgery if this becomes needed. Immediate cochlear implantation or placement of a cochlear lumen keeper during labyrinthectomy for MD is probably not necessary.
A central factor in pure tone auditory fatigue.
DOT National Transportation Integrated Search
1963-09-01
A long accumulation of psychophysical and physiological evidence indicates that auditory fatigue has its locus of effect in the cochlea; transfer studies with negative or questionable results, and studies of cochlear chemistry and potentials with pos...
Masking of infrared neural stimulation (INS) in hearing and deaf guinea pigs
NASA Astrophysics Data System (ADS)
Kadakia, Sama; Young, Hunter; Richter, Claus-Peter
2013-03-01
Spatial selective infrared neural stimulation has potential to improve neural prostheses, including cochlear implants. The heating of a confined target volume depolarizes the cell membrane and results in an action potential. Tissue heating may also results in thermal damage or the generation of a stress relaxation wave. Stress relaxation waves may result in a direct mechanical stimulation of remaining hair cells in the cochlea, so called optophony. Data are presented that quantify the effect of an acoustical stimulus (noise masker) on the response obtained with INS in normal hearing, acutely deafened, and chronic deaf animals. While in normal hearing animals an acoustic masker can reduce the response to INS, in acutely deafened animals the masking effect is reduced, and in chronic deaf animals this effect has not been detected. The responses to INS remain stable following the different degrees of cochlear damage.
Bertlich, Mattis; Ihler, Fritz; Sharaf, Kariem; Weiss, Bernhard G; Strupp, Michael; Canis, Martin
2014-10-01
Betahistine is a histamine-like drug that is used in the treatment of Ménière's disease. It is commonly believed that betahistine increases cochlear blood flow and thus decreases the endolymphatic hydrops that is the cause of Ménière's. Despite common clinical use, there is little understanding of the kinetics or effects of its metabolites. This study investigated the effect of the betahistine metabolites aminoethylpyridine, hydroxyethylpyridine, and pyridylacetic acid on cochlear microcirculation. Guinea pigs were randomly assigned to one of the groups: placebo, betahistine, or equimolar amounts of aminoethylpyridine, hydroxyethylpyridine, or pyridylacetic acid. Cochlear blood flow and mean arterial pressure were recorded for three minutes before and 15 minutes after treatment. Thirty Dunkin-Hartley guinea pigs assigned to one of five groups with six guinea pigs per group. Betahistine, aminoethylpyridine, and hydroxyethylpyridine caused a significant increase in cochlear blood flow in comparison to placebo. The effect seen under aminoethylpyridin was greatest. The group treated with pyridylacetic acid showed no significant effect on cochlear blood flow. Aminoethylpyridine and hydroxyethylpyridine are, like betahistine, able to increase cochlear blood flow significantly. The effect of aminoethylpyridine was greatest. Pyridylacetic acid had no effect on cochlear microcirculation.
[Cochlear implantation in patients with Waardenburg syndrome type II].
Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian
2010-05-01
To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.
[Cochlear implantation through the middle fossa approach].
Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M
2001-01-01
The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.
United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.
Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark
2013-11-01
Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.
Musical ear syndrome in adult cochlear implant patients.
Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W
2013-09-01
Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.
Large endolymphatic potentials from low-frequency and infrasonic tones in the guinea pig.
Salt, Alec N; Lichtenhan, Jeffery T; Gill, Ruth M; Hartsock, Jared J
2013-03-01
Responses of the ear to low-frequency and infrasonic sounds have not been extensively studied. Understanding how the ear responds to low frequencies is increasingly important as environmental infrasounds are becoming more pervasive from sources such as wind turbines. This study shows endolymphatic potentials in the third cochlear turn from acoustic infrasound (5 Hz) are larger than from tones in the audible range (e.g., 50 and 500 Hz), in some cases with peak-to-peak amplitude greater than 20 mV. These large potentials were suppressed by higher-frequency tones and were rapidly abolished by perilymphatic injection of KCl at the cochlear apex, demonstrating their third-turn origins. Endolymphatic iso-potentials from 5 to 500 Hz were enhanced relative to perilymphatic potentials as frequency was lowered. Probe and infrasonic bias tones were used to study the origin of the enhanced potentials. Potentials were best explained as a saturating response summed with a sinusoidal voltage (Vo), that was phase delayed by an average of 60° relative to the biasing effects of the infrasound. Vo is thought to arise indirectly from hair cell activity, such as from strial potential changes caused by sustained current changes through the hair cells in each half cycle of the infrasound.
Wake Vortex Detection: Phased Microphone vs. Linear Infrasonic Array
NASA Technical Reports Server (NTRS)
Shams, Qamar A.; Zuckerwar, Allan J.; Sullivan, Nicholas T.; Knight, Howard K.
2014-01-01
Sensor technologies can make a significant impact on the detection of aircraft-generated vortices in an air space of interest, typically in the approach or departure corridor. Current state-of-the art sensor technologies do not provide three-dimensional measurements needed for an operational system or even for wake vortex modeling to advance the understanding of vortex behavior. Most wake vortex sensor systems used today have been developed only for research applications and lack the reliability needed for continuous operation. The main challenges for the development of an operational sensor system are reliability, all-weather operation, and spatial coverage. Such a sensor has been sought for a period of last forty years. Acoustic sensors were first proposed and tested by National Oceanic and Atmospheric Administration (NOAA) early in 1970s for tracking wake vortices but these acoustic sensors suffered from high levels of ambient noise. Over a period of the last fifteen years, there has been renewed interest in studying noise generated by aircraft wake vortices, both numerically and experimentally. The German Aerospace Center (DLR) was the first to propose the application of a phased microphone array for the investigation of the noise sources of wake vortices. The concept was first demonstrated at Berlins Airport Schoenefeld in 2000. A second test was conducted in Tarbes, France, in 2002, where phased microphone arrays were applied to study the wake vortex noise of an Airbus 340. Similarly, microphone phased arrays and other opto-acoustic microphones were evaluated in a field test at the Denver International Airport in 2003. For the Tarbes and Denver tests, the wake trajectories of phased microphone arrays and lidar were compared as these were installed side by side. Due to a built-in pressure equalization vent these microphones were not suitable for capturing acoustic noise below 20 Hz. Our group at NASA Langley Research Center developed and installed an infrasonic array at the Newport News-Williamsburg International Airport early in the year 2013. A pattern of pressure burst, high-coherence intervals, and diminishing-coherence intervals was observed for all takeoff and landing events without exception. The results of a phased microphone vs. linear infrasonic array comparison will be presented.
Importance of cochlear health for implant function.
Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A
2015-04-01
Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled
The influence of cochlear shape on low-frequency hearing.
Manoussaki, Daphne; Chadwick, Richard S; Ketten, Darlene R; Arruda, Julie; Dimitriadis, Emilios K; O'Malley, Jen T
2008-04-22
The conventional theory about the snail shell shape of the mammalian cochlea is that it evolved essentially and perhaps solely to conserve space inside the skull. Recently, a theory proposed that the spiral's graded curvature enhances the cochlea's mechanical response to low frequencies. This article provides a multispecies analysis of cochlear shape to test this theory and demonstrates that the ratio of the radii of curvature from the outermost and innermost turns of the cochlear spiral is a significant cochlear feature that correlates strongly with low-frequency hearing limits. The ratio, which is a measure of curvature gradient, is a reflection of the ability of cochlear curvature to focus acoustic energy at the outer wall of the cochlear canal as the wave propagates toward the apex of the cochlea.
Dynamic tire pressure sensor for measuring ground vibration.
Wang, Qi; McDaniel, James Gregory; Wang, Ming L
2012-11-07
This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.
Dynamic Tire Pressure Sensor for Measuring Ground Vibration
Wang, Qi; McDaniel, James Gregory; Wang, Ming L.
2012-01-01
This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application. PMID:23202206
Duke, Mila Morais; Wolfe, Jace; Schafer, Erin
2016-05-01
Cochlear implant (CI) recipients often experience difficulty understanding speech in noise and speech that originates from a distance. Many CI recipients also experience difficulty understanding speech originating from a television. Use of hearing assistance technology (HAT) may improve speech recognition in noise and for signals that originate from more than a few feet from the listener; however, there are no published studies evaluating the potential benefits of a wireless HAT designed to deliver audio signals from a television directly to a CI sound processor. The objective of this study was to compare speech recognition in quiet and in noise of CI recipients with the use of their CI alone and with the use of their CI and a wireless HAT (Cochlear Wireless TV Streamer). A two-way repeated measures design was used to evaluate performance differences obtained in quiet and in competing noise (65 dBA) with the CI sound processor alone and with the sound processor coupled to the Cochlear Wireless TV Streamer. Sixteen users of Cochlear Nucleus 24 Freedom, CI512, and CI422 implants were included in the study. Participants were evaluated in four conditions including use of the sound processor alone and use of the sound processor with the wireless streamer in quiet and in the presence of competing noise at 65 dBA. Speech recognition was evaluated in each condition with two full lists of Computer-Assisted Speech Perception Testing and Training Sentence-Level Test sentences presented from a light-emitting diode television. Speech recognition in noise was significantly better with use of the wireless streamer compared to participants' performance with their CI sound processor alone. There was also a nonsignificant trend toward better performance in quiet with use of the TV Streamer. Performance was significantly poorer when evaluated in noise compared to performance in quiet when the TV Streamer was not used. Use of the Cochlear Wireless TV Streamer designed to stream audio from a television directly to a CI sound processor provides better speech recognition in quiet and in noise when compared to performance obtained with use of the CI sound processor alone. American Academy of Audiology.
Working memory in Farsi-speaking children with normal development and cochlear implant.
Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre
2014-04-01
Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p < 0.001). The children's age at implantation was negatively correlated with all tasks (p < 0.001). In contrast, duration of usage of cochlear implant set was positively correlated with all tasks (p < 0.001). The comparison of working memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p < 0.05). These results implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Cuomo, Frank W. (Inventor); Robbins, William E. (Inventor); Hopson, Purnell, Jr. (Inventor)
1992-01-01
A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a backplate for damping membrane motion. The backplate further provides a means for on-line calibration of the microphone.
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Cuomo, Frank W. (Inventor); Robbins, William E. (Inventor)
1993-01-01
A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a back plate for damping membrane motion. The back plate further provides a means for on-line calibration of the microphone.
Pilot study on the use of data mining to identify cochlear implant candidates.
Grisel, Jedidiah J; Schafer, Erin; Lam, Anne; Griffin, Terry
2018-05-01
The goal of this pilot study was to determine the clinical utility of data-mining software that screens for cochlear implant (CI) candidacy. The Auditory Implant Initiative developed a software module that screens for CI candidates via integration with a software system (Noah 4) that serves as a depository for hearing test data. To identify candidates, patient audiograms from one practice were exported into the screening module. Candidates were tracked to determine if any eventually underwent implantation. After loading 4836 audiograms from the Noah 4 system, the screening module identified 558 potential CI candidates. After reviewing the data for the potential candidates, 117 were targeted and invited to an educational event. Following the event, a total of six candidates were evaluated, and two were implanted. This objective approach to identifying candidates has the potential to address the gross underutilization of CIs by removing any bias or lack of knowledge regarding the management of severe to profound sensorineural hearing loss with CIs. The screening module was an effective tool for identifying potential CI candidates at one ENT practice. On a larger scale, the screening module has the potential to impact thousands of CI candidates worldwide.
A Background Noise Reduction Technique Using Adaptive Noise Cancellation for Microphone Arrays
NASA Technical Reports Server (NTRS)
Spalt, Taylor B.; Fuller, Christopher R.; Brooks, Thomas F.; Humphreys, William M., Jr.; Brooks, Thomas F.
2011-01-01
Background noise in wind tunnel environments poses a challenge to acoustic measurements due to possible low or negative Signal to Noise Ratios (SNRs) present in the testing environment. This paper overviews the application of time domain Adaptive Noise Cancellation (ANC) to microphone array signals with an intended application of background noise reduction in wind tunnels. An experiment was conducted to simulate background noise from a wind tunnel circuit measured by an out-of-flow microphone array in the tunnel test section. A reference microphone was used to acquire a background noise signal which interfered with the desired primary noise source signal at the array. The technique s efficacy was investigated using frequency spectra from the array microphones, array beamforming of the point source region, and subsequent deconvolution using the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm. Comparisons were made with the conventional techniques for improving SNR of spectral and Cross-Spectral Matrix subtraction. The method was seen to recover the primary signal level in SNRs as low as -29 dB and outperform the conventional methods. A second processing approach using the center array microphone as the noise reference was investigated for more general applicability of the ANC technique. It outperformed the conventional methods at the -29 dB SNR but yielded less accurate results when coherence over the array dropped. This approach could possibly improve conventional testing methodology but must be investigated further under more realistic testing conditions.
The Measurement of Unsteady Surface Pressure Using a Remote Microphone Probe.
Guan, Yaoyi; Berntsen, Carl R; Bilka, Michael J; Morris, Scott C
2016-12-03
Microphones are widely applied to measure pressure fluctuations at the walls of solid bodies immersed in turbulent flows. Turbulent motions with various characteristic length scales can result in pressure fluctuations over a wide frequency range. This property of turbulence requires sensing devices to have sufficient sensitivity over a wide range of frequencies. Furthermore, the small characteristic length scales of turbulent structures require small sensing areas and the ability to place the sensors in very close proximity to each other. The complex geometries of the solid bodies, often including large surface curvatures or discontinuities, require the probe to have the ability to be set up in very limited spaces. The development of a remote microphone probe, which is inexpensive, consistent, and repeatable, is described in the present communication. It allows for the measurement of pressure fluctuations with high spatial resolution and dynamic response over a wide range of frequencies. The probe is small enough to be placed within the interior of typical wind tunnel models. The remote microphone probe includes a small, rigid, and hollow tube that penetrates the model surface to form the sensing area. This tube is connected to a standard microphone, at some distance away from the surface, using a "T" junction. An experimental method is introduced to determine the dynamic response of the remote microphone probe. In addition, an analytical method for determining the dynamic response is described. The analytical method can be applied in the design stage to determine the dimensions and properties of the RMP components.
An experimental investigation of flow-induced oscillations of the Bruel and Kjaer in-flow microphone
NASA Technical Reports Server (NTRS)
Fields, Richard S., Jr.
1995-01-01
One source contributing to wind tunnel background noise is microphone self-noise. An experiment was conducted to investigate the flow-induced acoustic oscillations of Bruel & Kjaer (B&K) in-flow microphones. The results strongly suggest the B&K microphone cavity behaves more like an open cavity. Their cavity acoustic oscillations are likely caused by strong interactions between the cavity shear layer and the cavity trailing edge. But the results also suggest that cavity shear layer oscillations could be coupled with cavity acoustic resonance to generate tones. Detailed flow velocity measurements over the cavity screen have shown inflection points in the mean velocity profiles and high disturbance and spectral intensities in the vicinity of the cavity trailing edge. These results are the evidence for strong interactions between cavity shear layer oscillations and the cavity trailing edge. They also suggest that beside acoustic signals, the microphone inside the cavity has likely recorded hydrodynamic pressure oscillations, too. The results also suggest that the forebody shape does not have a direct effect on cavity oscillations. For the FITE (Flow Induced Tone Eliminator) microphone, it is probably the forebody length and the resulting boundary layer turbulence that have made it work. Turbulence might have thickened the boundary layer at the separation point, weakened the shear layer vortices, or lifted them to miss impinging on the cavity trailing edge. In addition, the study shows that the cavity screen can modulate the oscillation frequency but not the cavity acoustic oscillation mechanisms.
The Semicircular Canal Microphonic
NASA Technical Reports Server (NTRS)
Rabbitt, R. D.; Boyle, R.; Highstein, S. M.; Dalton, Bonnie P. (Technical Monitor)
2002-01-01
Present experiments were designed to quantify the alternating current (AC) component of the semicircular canal microphonic for angular motion stimulation as a function of stimulus frequency and amplitude. The oyster toadfish, Opsanus tau, was used as the experimental model. Calibrated mechanical indentation of the horizontal canal duct was used as a stimulus to generate hair-cell and afferent responses reproducing those present during head rotation. Sensitivity to polarization of the endolymph DC voltage re: perilymph was also investigated. Modulation of endolymph voltage was recorded using conventional glass electrodes and lock-in amplification over the frequency range 0.2-80 Hz. Access to the endolymph for inserting voltage recording and current passing electrodes was obtained by sectioning the anterior canal at its apex and isolating the cut ends in air. For sinusoidal stimulation below approx.10 Hz, the horizontal semicircular canal AC microphonic was nearly independent of stimulus frequency and equal to approximately 4 microV per micron indent (equivalent to approx. 1 microV per deg/s). A saturating nonlinearity decreasing the microphonic gain was present for stimuli exceeding approx.3 micron indent (approx. 12 deg/s angular velocity). The phase was not sensitive to the saturating nonlinearity. The microphonic exhibited a resonance near 30Hz consistent with basolateral current hair cell resonance observed previously in voltage-clamp records from semicircular canal hair cells. The magnitude and phase of the microphonic exhibited sensitivity to endolymphatic polarization consistent with electro-chemical reversal of hair cell transduction currents.
Chang, David T; Ko, Alvin B; Murray, Gail S; Arnold, James E; Megerian, Cliff A
2010-07-01
(1) To analyze if socioeconomic status influences access to cochlear implantation in an environment with adequate Medicaid reimbursement. (2) To determine the impact of socioeconomic status on outcomes after unilateral cochlear implantation. Retrospective cohort study. University Hospitals Case Medical Center and Rainbow Babies and Children's Hospital (tertiary referral center), Cleveland, Ohio. Pediatric patients (age range, newborn to 18 years) who received unilateral cochlear implantation during the period 1996 to 2008. Access to cochlear implantation after referral to a cochlear implant center, postoperative complications, compliance with follow-up appointments, and access to sequential bilateral cochlear implantation. A total of 133 pediatric patients were included in this study; 64 were Medicaid-insured patients and 69 were privately insured patients. There was no statistical difference in the odds of initial cochlear implantation, age at referral, or age at implantation between the 2 groups. The odds of prelingual Medicaid-insured patients receiving sequential bilateral cochlear implantation was less than half that of the privately insured group (odds ratio [OR], 0.43; P = .03). The odds of complications in Medicaid-insured children were almost 5-fold greater than the odds for privately insured children (OR, 4.6; P = .03). There were 10 complications in 51 Medicaid-insured patients (19.6%) as opposed to 3 in 61 privately insured patients (4.9%). Medicaid-insured patients missed substantially more follow-up appointments overall (35% vs 23%) and more consecutive visits (1.9 vs 1.1) compared with privately insured patients. In an environment with adequate Medicaid reimbursement, eligible children have equal access to cochlear implantation, regardless of socioeconomic background. However, lower socioeconomic background is associated with higher rates of postoperative complications, worse follow-up compliance, and lower rates of sequential bilateral implantation, observed herein in Medicaid-insured patients. These findings present opportunities for cochlear implant centers to create programs to address such downstream disparities.
Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon
2018-05-18
Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Dong, Wei; Olson, Elizabeth S
2010-03-01
Distortion product otoacoustic emissions (DPOAEs) originate in cochlear nonlinearity and emerge into the ear canal as an apparent sum of emission types, one of which (generator) travels directly out and the other (reflector) travels out following linear reflection. The present study explores intracochlear sources of DPOAEs via simultaneous ear canal and intracochlear pressure measurements in gerbils. A locally damaged cochlea was produced with reduced local intracochlear nonlinearity and significant elevation of the compound action potential thresholds at frequencies represented within the damaged region. In the DPOAE the comparison of healthy to locally damaged cochleae showed the following: (1) In the broad frequency region corresponding to the locally damaged best frequency, DPOAEs evoked by wider f(2)/f(1) stimuli decreased, consistent with the reduction in local nonlinearity. (2) DPOAEs evoked by narrow f(2)/f(1) stimuli often had a bimodal change, decreasing in a lower frequency band and increasing in a band just adjacent and higher, and the DPOAE phase-vs-frequency slope steepened. These changes confirm the complex nature of the DPOAE.
Todt, Ingo; Basta, Dietmar; Ernst, Arne
2008-01-01
To investigate the impact of different cochleostomy techniques on vestibular receptor integrity and vertigo after cochlear implantation. Retrospective cohort study. A total of 62 patients (17 to 84 years of age) underwent implantation via an anterior or round window insertion approach. Two groups of cochlear implant patients were compared with respect to their pre- and postoperative vestibular function and the occurrence of postoperative vertigo. The data were related to the different cochleostomy techniques. The patients were tested by a questionnaire (dizziness handicap inventory, DIH), caloric irrigation (vestibulo-ocular reflex, VOR) for the function of the lateral SCC and by vestibular evoked myogenic potential (VEMP) recordings for saccular function. Significant differences of postoperative VEMP responses (50% vs 13%) and electromystagmography (ENG) results (42.9% vs 9.4%) were found with respect to the 2 different insertion techniques. The number of patients with vertigo after the surgery as evidenced by DHI (23% vs 12.5%) was significantly different. The used round window approach for electrode insertion should be preferred to decrease the risk of loss of vestibular function and the occurrence of vertigo.
ZHANG, CELIA; SUN, WEI; LI, JI; XIONG, BINBIN; FRYE, MITCHELL D.; DING, DALIAN; SALVI, RICHARD; KIM, MI-JUNG; SOMEYA, SHINICHI; HU, BO HUA
2017-01-01
Sestrin 2 (SESN2) is a stress-inducible protein that protects tissues from oxidative stress and delays the aging process. However, its role in maintaining the functional and structural integrity of the cochlea is largely unknown. Here, we report the expression of SESN2 protein in the sensory epithelium, particularly in hair cells. Using C57BL/6J mice, a mouse model of age-related cochlear degeneration, we observed a significant age-related reduction in SESN2 expression in cochlear tissues that was associated with early onset hearing loss and accelerated age-related sensory cell degeneration that progressed from the base toward the apex of the cochlea. Hair cell death occurred by caspase-8 mediated apoptosis. Compared to C57BL/6J control mice, Sesn2 KO mice displayed enhanced expression of proinflammatory genes and activation of basilar membrane macrophages, suggesting that loss of SESN2 function provokes the immune response. Together, these results suggest that Sesn2 plays an important role in cochlear homeostasis and immune responses to stress. PMID:28818524
Mens, Lucas H. M.
2007-01-01
During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to monitor the proper functioning of the implanted electronics and electrode contacts. Telemetry can also support the clinical management in young children and difficult cases where neural unresponsiveness is suspected. This article will review recent advances in the telemetry of the electrically evoked compound action potential that have made these measurements simple and routine procedures in most cases. The distribution of the electrical stimulus itself sampled by “electrical field imaging” reveals general patterns of current flow in the normal cochlea and gross abnormalities in individual patients; models have been developed to derive more subtle insights from an individual electrical field imaging. Finally, some thoughts are given to the extended application of telemetry, for example, in monitoring the neural responses or in combination with other treatments of the deaf ear. PMID:17709572
Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.
Cuda, D; Murri, A; Succo, G
2013-04-01
We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.
Moein, Narges; Khoddami, Seyyedeh Maryam; Shahbodaghi, Mohammad Rahim
2017-10-01
Cochlear implant prosthesis facilitates spoken language development and speech comprehension in children with severe-profound hearing loss. However, this prosthesis is limited in encoding information about fundamental frequency and pitch that are essentially for recognition of speech prosody. The purpose of the present study is to investigate the perception and production of intonation in cochlear implant children and comparison with normal hearing children. This study carried out on 25 cochlear implanted children and 50 children with normal hearing. First, using 10 action pictures statements and questions sentences were extracted. Fundamental frequency and pitch changes were identified using Praat software. Then, these sentences were judged by 7 adult listeners. In second stage 20 sentences were played for child and he/she determined whether it was in a question form or statement one. Performance of cochlear implanted children in perception and production of intonation was significantly lower than children with normal hearing. The difference between fundamental frequency and pitch changes in cochlear implanted children and children with normal hearing was significant (P < 0/05). Cochlear implanted children performance in perception and production of intonation has significant correlation with child's age surgery and duration of prosthesis use (P < 0/05). The findings of the current study show that cochlear prostheses have limited application in facilitating the perception and production of intonation in cochlear implanted children. It should be noted that the child's age at the surgery and duration of prosthesis's use is important in reduction of this limitation. According to these findings, speech and language pathologists should consider intervention of intonation in treatment program of cochlear implanted children. Copyright © 2017 Elsevier B.V. All rights reserved.
Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J
2017-06-01
Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve. © 2017 by American Journal of Neuroradiology.
DIY Soundcard Based Temperature Logging System. Part I: Design
ERIC Educational Resources Information Center
Nunn, John
2016-01-01
This paper aims to enable schools to make their own low-cost temperature logging instrument and to learn something about its calibration in the process. This paper describes how a thermistor can be integrated into a simple potential divider circuit which is powered with the sound output of a computer and monitored by the microphone input. The…
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
Response Properties of Cochlear Nucleus Neurons in Monkeys
Roth, G. Linn; Recio, A.
2009-01-01
Much of what is known about how the cochlear nuclei participate in mammalian hearing comes from studies of non-primate mammalian species. To determine to what extent the cochlear nuclei of primates resemble those of other mammalian orders, we have recorded responses to sound in three primate species: marmosets, Cynomolgus macaques, and squirrel monkeys. These recordings show that the same types of temporal firing patterns are found in primates that have been described in other mammals. Responses to tones of neurons in the ventral cochlear nucleus have similar tuning, latencies, post-stimulus time and interspike interval histograms as those recorded in non-primate cochlear nucleus neurons. In the dorsal cochlear nucleus, too, responses were similar. From these results it is evident that insights gained from non-primate studies can be applied to the peripheral auditory system of primates. PMID:19531377
Monshizadeh, Leila; Vameghi, Roshanak; Sajedi, Firoozeh; Yadegari, Fariba; Hashemi, Seyed Basir; Kirchem, Petra; Kasbi, Fatemeh
2018-04-01
A cochlear implant is a device that helps hearing-impaired children by transmitting sound signals to the brain and helping them improve their speech, language, and social interaction. Although various studies have investigated the different aspects of speech perception and language acquisition in cochlear-implanted children, little is known about their social skills, particularly Persian-speaking cochlear-implanted children. Considering the growing number of cochlear implants being performed in Iran and the increasing importance of developing near-normal social skills as one of the ultimate goals of cochlear implantation, this study was performed to compare the social interaction between Iranian cochlear-implanted children who have undergone rehabilitation (auditory verbal therapy) after surgery and normal-hearing children. This descriptive-analytical study compared the social interaction level of 30 children with normal hearing and 30 with cochlear implants who were conveniently selected. The Raven test was administered to the both groups to ensure normal intelligence quotient. The social interaction status of both groups was evaluated using the Vineland Adaptive Behavior Scale, and statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 21. After controlling age as a covariate variable, no significant difference was observed between the social interaction scores of both the groups (p > 0.05). In addition, social interaction had no correlation with sex in either group. Cochlear implantation followed by auditory verbal rehabilitation helps children with sensorineural hearing loss to have normal social interactions, regardless of their sex.
Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.
Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo
2017-09-01
to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.
Preliminary evaluation of a novel bone-conduction device for single-sided deafness.
Popelka, Gerald R; Derebery, Jennifer; Blevins, Nikolas H; Murray, Michael; Moore, Brian C J; Sweetow, Robert W; Wu, Ben; Katsis, Mina
2010-04-01
A new intraoral bone-conduction device has advantages over existing bone-conduction devices for reducing the auditory deficits associated with single-sided deafness (SSD). Existing bone-conduction devices effectively mitigate auditory deficits from single-sided deafness but have suboptimal microphone locations, limited frequency range, and/or require invasive surgery. A new device has been designed to improve microphone placement (in the ear canal of the deaf ear), provide a wider frequency range, and eliminate surgery by delivering bone-conduction signals to the teeth via a removable oral appliance. Forces applied by the oral appliance were compared with forces typically experienced by the teeth from normal functions such as mastication or from other appliances. Tooth surface changes were measured on extracted teeth, and transducer temperature was measured under typical use conditions. Dynamic operating range, including gain, bandwidth, and maximum output limits, were determined from uncomfortable loudness levels and vibrotactile thresholds, and speech recognition scores were measured using normal-hearing subjects. Auditory performance in noise (Hearing in Noise Test) was measured in a limited sample of SSD subjects. Overall comfort, ease of insertion, and removal and visibility of the oral appliance in comparison with traditional hearing aids were measured using a rating scale. The oral appliance produces forces that are far below those experienced by the teeth from normal functions or conventional dental appliances. The bone-conduction signal level can be adjusted to prevent tactile perception yet provide sufficient gain and output at frequencies from 250 to 12,000 Hz. The device does not damage tooth surfaces nor produce heat, can be inserted and removed easily, and is as comfortable to wear as traditional hearing aids. The new microphone location has advantages for reducing the auditory deficits caused by SSD, including the potential to provide spatial cues introduced by reflections from the pinna, compared with microphone locations for existing devices. A new approach for SSD has been proposed that optimizes microphone location and delivers sound by bone conduction through a removable oral appliance. Measures in the laboratory using normal-hearing subjects indicate that the device provides useful gain and output for SSD patients, is comfortable, does not seem to have detrimental effects on oral function or oral health, and has several advantages over existing devices. Specifically, microphone placement is optimized for reducing the auditory deficit caused by SSD, frequency bandwidth is much greater, and the system does not require surgical placement. Auditory performance in a small sample of SSD subjects indicated a substantial advantage compared with not wearing the device. Future studies will involve performance measures on SSD patients wearing the device for longer periods.
NASA Technical Reports Server (NTRS)
Greenwood, Eric II; Schmitz, Fredric H.
2009-01-01
A new method of separating the contributions of helicopter main and tail rotor noise sources is presented, making use of ground-based acoustic measurements. The method employs time-domain de-Dopplerization to transform the acoustic pressure time-history data collected from an array of ground-based microphones to the equivalent time-history signals observed by an array of virtual inflight microphones traveling with the helicopter. The now-stationary signals observed by the virtual microphones are then periodically averaged with the main and tail rotor once per revolution triggers. The averaging process suppresses noise which is not periodic with the respective rotor, allowing for the separation of main and tail rotor pressure time-histories. The averaged measurements are then interpolated across the range of directivity angles captured by the microphone array in order to generate separate acoustic hemispheres for the main and tail rotor noise sources. The new method is successfully applied to ground-based microphone measurements of a Bell 206B3 helicopter and demonstrates the strong directivity characteristics of harmonic noise radiation from both the main and tail rotors of that helicopter.
Assessment of ground effects on the propagation of aircraft noise: The T-38A flight experiment
NASA Technical Reports Server (NTRS)
Willshire, W. L., Jr.
1980-01-01
A flight experiment was conducted to investigate air to ground propagation of sound at gazing angles of incidence. A turbojet powered airplane was flown at altitudes ranging from 10 to 160 m over a 20-microphone array positioned over grass and concrete. The dependence of ground effects on frequency, incidence angle, and slant range was determined using two analysis methods. In one method, a microphone close to the flight path is compared to down range microphones. In the other method, comparisons are made between two microphones which were equidistant from the flight path but positioned over the two surfaces. In both methods, source directivity angle was the criterion by which portions of the microphone signals were compared. The ground effects were largest in the frequency range of 200 to 400 Hz and were found to be dependent on incidence angle and slant range. Ground effects measured for angles of incidence greater than 10 deg to 15 deg were near zero. Measured attenuation increased with increasing slant range for slant ranges less than 750 m. Theoretical predictions were found to be in good agreement with the major details of the measured results.
Zuckerwar, Allan J; Herring, G C; Elbing, Brian R
2006-01-01
A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that can plague FF measurements. Calibrations were performed on 1/4-in. FF air-condenser, electret, and microelectromechanical systems (MEMS) microphones in an anechoic chamber. The uncertainty of this FF method is estimated by comparing the pressure sensitivity of an air-condenser FF microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration. The root-mean-square difference is found to be +/- 0.3 dB over the range 1-80 kHz, and the combined standard uncertainty of the FF method, including other significant contributions, is +/- 0.41 dB.
Evaluation of a scale-model experiment to investigate long-range acoustic propagation
NASA Technical Reports Server (NTRS)
Parrott, Tony L.; Mcaninch, Gerry L.; Carlberg, Ingrid A.
1987-01-01
Tests were conducted to evaluate the feasibility of using a scale-model experiment situated in an anechoic facility to investigate long-range sound propagation over ground terrain. For a nominal scale factor of 100:1, attenuations along a linear array of six microphones colinear with a continuous-wave type of sound source were measured over a wavelength range from 10 to 160 for a nominal test frequency of 10 kHz. Most tests were made for a hard model surface (plywood), but limited tests were also made for a soft model surface (plywood with felt). For grazing-incidence propagation over the hard surface, measured and predicted attenuation trends were consistent for microphone locations out to between 40 and 80 wavelengths. Beyond 80 wavelengths, significant variability was observed that was caused by disturbances in the propagation medium. Also, there was evidence of extraneous propagation-path contributions to data irregularities at more remote microphones. Sensitivity studies for the hard-surface and microphone indicated a 2.5 dB change in the relative excess attenuation for a systematic error in source and microphone elevations on the order of 1 mm. For the soft-surface model, no comparable sensitivity was found.
Advanced flow noise reducing acoustic sensor arrays
NASA Astrophysics Data System (ADS)
Fine, Kevin; Drzymkowski, Mark; Cleckler, Jay
2009-05-01
SARA, Inc. has developed microphone arrays that are as effective at reducing flow noise as foam windscreens and sufficiently rugged for tough battlefield environments. These flow noise reducing (FNR) sensors have a metal body and are flat and conformally mounted so they can be attached to the roofs of land vehicles and are resistant to scrapes from branches. Flow noise at low Mach numbers is created by turbulent eddies moving with the fluid flow and inducing pressure variations on microphones. Our FNR sensors average the pressure over the diameter (~20 cm) of their apertures, reducing the noise created by all but the very largest eddies. This is in contrast to the acoustic wave which has negligible variation over the aperture at the frequencies of interest (f less or equal than 400 Hz). We have also post-processed the signals to further reduce the flow noise. Two microphones separated along the flow direction exhibit highly correlated noise. The time shift of the correlation corresponds to the time for the eddies in the flow to travel between the microphones. We have created linear microphone arrays parallel to the flow and have reduced flow noise as much as 10 to 15 dB by subtracting time-shifted signals.
Talker Localization Based on Interference between Transmitted and Reflected Audible Sound
NASA Astrophysics Data System (ADS)
Nakayama, Masato; Nakasako, Noboru; Shinohara, Toshihiro; Uebo, Tetsuji
In many engineering fields, distance to targets is very important. General distance measurement method uses a time delay between transmitted and reflected waves, but it is difficult to estimate the short distance. On the other hand, the method using phase interference to measure the short distance has been known in the field of microwave radar. Therefore, we have proposed the distance estimation method based on interference between transmitted and reflected audible sound, which can measure the distance between microphone and target with one microphone and one loudspeaker. In this paper, we propose talker localization method based on distance estimation using phase interference. We expand the distance estimation method using phase interference into two microphones (microphone array) in order to estimate talker position. The proposed method can estimate talker position by measuring the distance and direction between target and microphone array. In addition, talker's speech is regarded as a noise in the proposed method. Therefore, we also propose combination of the proposed method and CSP (Cross-power Spectrum Phase analysis) method which is one of the DOA (Direction Of Arrival) estimation methods. We evaluated the performance of talker localization in real environments. The experimental result shows the effectiveness of the proposed method.
Keidser, Gitte; Rohrseitz, Kristin; Dillon, Harvey; Hamacher, Volkmar; Carter, Lyndal; Rass, Uwe; Convery, Elizabeth
2006-10-01
This study examined the effect that signal processing strategies used in modern hearing aids, such as multi-channel WDRC, noise reduction, and directional microphones have on interaural difference cues and horizontal localization performance relative to linear, time-invariant amplification. Twelve participants were bilaterally fitted with BTE devices. Horizontal localization testing using a 360 degrees loudspeaker array and broadband pulsed pink noise was performed two weeks, and two months, post-fitting. The effect of noise reduction was measured with a constant noise present at 80 degrees azimuth. Data were analysed independently in the left/right and front/back dimension and showed that of the three signal processing strategies, directional microphones had the most significant effect on horizontal localization performance and over time. Specifically, a cardioid microphone could decrease front/back errors over time, whereas left/right errors increased when different microphones were fitted to left and right ears. Front/back confusions were generally prominent. Objective measurements of interaural differences on KEMAR explained significant shifts in left/right errors. In conclusion, there is scope for improving the sense of localization in hearing aid users.
New Perspectives on Assessing Amplification Effects
Souza, Pamela E.; Tremblay, Kelly L.
2006-01-01
Clinicians have long been aware of the range of performance variability with hearing aids. Despite improvements in technology, there remain many instances of well-selected and appropriately fitted hearing aids whereby the user reports minimal improvement in speech understanding. This review presents a multistage framework for understanding how a hearing aid affects performance. Six stages are considered: (1) acoustic content of the signal, (2) modification of the signal by the hearing aid, (3) interaction between sound at the output of the hearing aid and the listener's ear, (4) integrity of the auditory system, (5) coding of available acoustic cues by the listener's auditory system, and (6) correct identification of the speech sound. Within this framework, this review describes methodology and research on 2 new assessment techniques: acoustic analysis of speech measured at the output of the hearing aid and auditory evoked potentials recorded while the listener wears hearing aids. Acoustic analysis topics include the relationship between conventional probe microphone tests and probe microphone measurements using speech, appropriate procedures for such tests, and assessment of signal-processing effects on speech acoustics and recognition. Auditory evoked potential topics include an overview of physiologic measures of speech processing and the effect of hearing loss and hearing aids on cortical auditory evoked potential measurements in response to speech. Finally, the clinical utility of these procedures is discussed. PMID:16959734
Use of suprathreshold stochastic resonance in cochlear implant coding
NASA Astrophysics Data System (ADS)
Allingham, David; Stocks, Nigel G.; Morse, Robert P.
2003-05-01
In this article we discuss the possible use of a novel form of stochastic resonance, termed suprathreshold stochastic resonance (SSR), to improve signal encoding/transmission in cochlear implants. A model, based on the leaky-integrate-and-fire (LIF) neuron, has been developed from physiological data and use to model information flow in a population of cochlear nerve fibers. It is demonstrated that information flow can, in principle, be enhanced by the SSR effect. Furthermore, SSR was found to enhance information transmission for signal parameters that are commonly encountered in cochlear implants. This, therefore, gives hope that SSR may be implemented in cochlear implants to improve speech comprehension.
Noise measurements of turboprop airplanes at different overflight elevations
NASA Technical Reports Server (NTRS)
Mueller, K.
1990-01-01
In order to establish criteria for the regulation of propfan aircraft engine noise emissions, measurement tests of overhead flights of a METRO-3 and a FOKKER-50 aircraft were performed. The decibel levels captured by the ground car microphone are tabulated according to the height of the microphone from the ground as the recording vehicle followed the aircraft through the test flight patterns. Microphone heights of 1.5 and 10 meters from the ground are recorded and correlated to the flight altitudes of the aircraft, which ranged from 5182-6401 meters.
Round-window delivery of neurotrophin 3 regenerates cochlear synapses after acoustic overexposure.
Suzuki, Jun; Corfas, Gabriel; Liberman, M Charles
2016-04-25
In acquired sensorineural hearing loss, such as that produced by noise or aging, there can be massive loss of the synaptic connections between cochlear sensory cells and primary sensory neurons, without loss of the sensory cells themselves. Because the cell bodies and central projections of these cochlear neurons survive for months to years, there is a long therapeutic window in which to re-establish functional connections and improve hearing ability. Here we show in noise-exposed mice that local delivery of neurotrophin-3 (NT-3) to the round window niche, 24 hours after an exposure that causes an immediate loss of up to 50% loss of synapses in the cochlear basal region, can regenerate pre- and post-synaptic elements at the hair cell / cochlear nerve interface. This synaptic regeneration, as documented by confocal microscopy of immunostained cochlear sensory epithelia, was coupled with a corresponding functional recovery, as seen in the suprathreshold amplitude of auditory brainstem response Wave 1. Cochlear delivery of neurotrophins in humans is likely achievable as an office procedure via transtympanic injection, making our results highly significant in a translational context.
Micromachined microphone array on a chip for turbulent boundary layer measurements
NASA Astrophysics Data System (ADS)
Krause, Joshua Steven
A surface micromachined microphone array on a single chip has been successfully designed, fabricated, characterized, and tested for aeroacoustic purposes. The microphone was designed to have venting through the diaphragm, 64 elements (8x8) on the chip, and used a capacitive transduction scheme. The microphone was fabricated using the MEMSCAP PolyMUMPs process (a foundry polysilicon surface micromachining process) along with facilities at Tufts Micro and Nano Fabrication Facility (TMNF) where a Parylene-C passivation layer deposition and release of the microstructures were performed. The devices are packaged with low profile interconnects, presenting a maximum of 100 mum of surface topology. The design of an individual microphone was completed through the use of a lumped element model (LEM) to determine the theoretical performance of the microphone. Off-chip electronics were created to allow the microphone array outputs to be redirected to one of two channels, allowing dynamic reconfiguration of the effective transducer shape in software and provide 80 dB off isolation. The characterization was completed through the use of laser Doppler vibrometry (LDV), acoustic plane wave tube and free-field calibration, and electrical noise floor testing in a Faraday cage. Measured microphone sensitivity is 0.15 mV/Pa for an individual microphone and 8.7 mV/Pa for the entire array, in close agreement with model predictions. The microphones and electronics operate over the 200--40 000 Hz band. The dynamic range extends from 60 dB SPL in a 1 Hz band to greater than 150 dB SPL. Element variability was +/-0.05 mV/Pa in sensitivity with an array yield of 95%. Wind tunnel testing at flow rates of up to 205.8 m/s indicates that the devices continue to operate in flow without damage, and can be successfully reconfigured on the fly. Care has been taken to systematically remove contaminating signals (acoustic, vibration, and noise floor) from the wind tunnel data to determine actual turbulent pressure fluctuations beneath the turbulent boundary layer to an uncertainty level of 1 dB. Analysis of measured boundary layer pressure spectra at six flow rates from 34.3 m/s to 205.8 m/s indicate single point wall spectral measurements in close agreement to the empirical models of Goody, Chase-Howe, and Efimtsov above Mach 0.4. The MEMS data more closely resembles the magnitude of the Efimtsov model at higher frequencies (25% higher above 3 kHz for the Mach 0.6 case); however, the shape of the spectral model is closer to the model of Goody (50% lower for the Mach 0.6 case for all frequencies). The Chase-Howe model does fall directly on the MEMS data starting at 6 kHz, but has a sharper slope and does not resemble the data at below 6 kHz.
Stochastic information transfer from cochlear implant electrodes to auditory nerve fibers
NASA Astrophysics Data System (ADS)
Gao, Xiao; Grayden, David B.; McDonnell, Mark D.
2014-08-01
Cochlear implants, also called bionic ears, are implanted neural prostheses that can restore lost human hearing function by direct electrical stimulation of auditory nerve fibers. Previously, an information-theoretic framework for numerically estimating the optimal number of electrodes in cochlear implants has been devised. This approach relies on a model of stochastic action potential generation and a discrete memoryless channel model of the interface between the array of electrodes and the auditory nerve fibers. Using these models, the stochastic information transfer from cochlear implant electrodes to auditory nerve fibers is estimated from the mutual information between channel inputs (the locations of electrodes) and channel outputs (the set of electrode-activated nerve fibers). Here we describe a revised model of the channel output in the framework that avoids the side effects caused by an "ambiguity state" in the original model and also makes fewer assumptions about perceptual processing in the brain. A detailed comparison of how different assumptions on fibers and current spread modes impact on the information transfer in the original model and in the revised model is presented. We also mathematically derive an upper bound on the mutual information in the revised model, which becomes tighter as the number of electrodes increases. We found that the revised model leads to a significantly larger maximum mutual information and corresponding number of electrodes compared with the original model and conclude that the assumptions made in this part of the modeling framework are crucial to the model's overall utility.
Hamerschmidt, Rogério; Schuch, Luiz Henrique; Rezende, Rodrigo Kopp; Wiemes, Gislaine Richter Minhoto; Oliveira, Adriana Kosma Pires de; Mocellin, Marcos
2012-01-01
There are two techniques for cochlear implant (CI) electrode placement: cochleostomy and the round window (RW) approach. This study aims to compare neural response telemetry (NRT) results immediately after surgery to check for possible differences on auditory nerve stimulation between these two techniques. This is a prospective cross-sectional study. Twenty-three patients were enrolled. Six patients underwent surgery by cochleostomy and 17 had it through the RW approach. Mean charge units (MCU) for high frequency sounds: patients submitted to the RW approach had a mean value of 190.4 (± 29.2) while cochleostomy patients averaged 187.8 (± 32.7); p = 0.71. MCU for mid frequency sounds: patients submitted to the RW approach had a mean value of 192.5 (± 22) while cochleostomy patients averaged 178.5 (± 18.5); p = 0.23. MCU for low frequency sounds: patients submitted to the RW approach had a mean value of 183.3 (± 25) while cochleostomy patients averaged 163.8 (± 19.3); p = 0.19. This study showed no differences in the action potential of the distal portion of the auditory nerve in patients with multichannel cochlear implants submitted to surgery by cochleostomy or through the RW approach, using the implant itself to generate stimuli and record responses. Both techniques equally stimulate the cochlear nerve. Therefore, the choice of approach can be made based on the surgeon's own preference and experience.
Differential distribution of adenosine receptors in rat cochlea.
Vlajkovic, Srdjan M; Abi, Shukri; Wang, Carol J H; Housley, Gary D; Thorne, Peter R
2007-06-01
Adenosine is a constitutive cell metabolite that can be released from cells via specific bi-directional transporters and is an end-point for nucleotide hydrolysis. In the extracellular space, adenosine becomes a signalling molecule for P1 (adenosine) receptors that modulate physiological responses in a wide range of mammalian tissues. Whereas adenosine signalling has been implicated in the regulation of cochlear blood flow and in cochlear protection from oxidative damage, the potential roles for adenosine signalling in the modulation of sound transduction and auditory neurotransmission have not been established. We have characterised the expression and distribution of adenosine receptors in the rat cochlea. mRNA transcripts for all four subtypes of adenosine receptors (A(1), A(2A), A(2B) and A(3)) were detected in dissected cochlear tissue by using reverse transcription/polymerase chain reaction analysis. The protein distribution for the A(1), A(2A) and A(3) receptor subtypes was identified by immunoperoxidase histochemistry and confocal immunofluorescence labelling. These receptors were differentially expressed in the organ of Corti, spiral ganglion neurones, lateral wall tissues and cochlear blood vessels. The distribution of adenosine receptors in sensory and neural tissues and in the vasculature coincided with other elements of purinergic signalling (P2X and P2Y receptors, ectonucleotidases), consistent with the integrative regulation of many physiological processes in the cochlea by extracellular nucleotides and nucleosides. Our study provides a framework for further investigation of adenosine signalling in the inner ear, including putative roles in oxidative stress responses.
Probabilistic Tractography of the Cranial Nerves in Vestibular Schwannoma.
Zolal, Amir; Juratli, Tareq A; Podlesek, Dino; Rieger, Bernhard; Kitzler, Hagen H; Linn, Jennifer; Schackert, Gabriele; Sobottka, Stephan B
2017-11-01
Multiple recent studies have reported on diffusion tensor-based fiber tracking of cranial nerves in vestibular schwannoma, with conflicting results as to the accuracy of the method and the occurrence of cochlear nerve depiction. Probabilistic nontensor-based tractography might offer advantages in terms of better extraction of directional information from the underlying data in cranial nerves, which are of subvoxel size. Twenty-one patients with large vestibular schwannomas were recruited. The probabilistic tracking was run preoperatively and the position of the potential depictions of the facial and cochlear nerves was estimated postoperatively by 3 independent observers in a blinded fashion. The true position of the nerve was determined intraoperatively by the surgeon. Thereafter, the imaging-based estimated position was compared with the intraoperatively determined position. Tumor size, cystic appearance, and postoperative House-Brackmann score were analyzed with regard to the accuracy of the depiction of the nerves. The probabilistic tracking showed a connection that correlated to the position of the facial nerve in 81% of the cases and to the position of the cochlear nerve in 33% of the cases. Altogether, the resulting depiction did not correspond to the intraoperative position of any of the nerves in 3 cases. In a majority of cases, the position of the facial nerve, but not of the cochlear nerve, could be estimated by evaluation of the probabilistic tracking results. However, false depictions not corresponding to any nerve do occur and cannot be discerned as such from the image only. Copyright © 2017 Elsevier Inc. All rights reserved.
Auditory Midbrain Implant: Research and Development Towards a Second Clinical Trial
Lim, Hubert H.; Lenarz, Thomas
2015-01-01
The cochlear implant is considered one of the most successful neural prostheses to date, which was made possible by visionaries who continued to develop the cochlear implant through multiple technological and clinical challenges. However, patients without a functional auditory nerve or implantable cochlea cannot benefit from a cochlear implant. The focus of the paper is to review the development and translation of a new type of central auditory prosthesis for this group of patients, which is known as the auditory midbrain implant (AMI) and is designed for electrical stimulation within the inferior colliculus. The rationale and results for the first AMI clinical study using a multi-site single-shank array will be presented initially. Although the AMI has achieved encouraging results in terms of safety and improvements in lip-reading capabilities and environmental awareness, it has not yet provided sufficient speech perception. Animal and human data will then be presented to show that a two-shank AMI array can potentially improve hearing performance by targeting specific neurons of the inferior colliculus. Modifications to the AMI array design, stimulation strategy, and surgical approach have been made that are expected to improve hearing performance in the patients implanted with a two-shank array in an upcoming clinical trial funded by the National Institutes of Health. Positive outcomes from this clinical trial will motivate new efforts and developments toward improving central auditory prostheses for those who cannot sufficiently benefit from cochlear implants. PMID:25613994
Prevention of Noise Damage to Cochlear Synapses
2015-10-01
AWARD NUMBER: W81XWH-14-1-0494 TITLE: Prevention of Noise Damage to Cochlear Synapses PRINCIPAL INVESTIGATOR: Steven Green CONTRACTING...to Cochlear Synapses 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-1-0494 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Steven Green 5d. PROJECT...ABSTRACT Noise-induced synaptopathy is the result of excitotoxic trauma to cochlear synapses due to glutamate released from the hair cells. Excitotoxic
49 CFR 325.7 - Allowable noise levels.
Code of Federal Regulations, 2010 CFR
2010-10-01
... distance between the microphone location point and the microphone target point is— 31 ft ( 9.5m) or more... is based on motor carrier noise emission requirements specified in 40 CFR 202.20 and 40 CFR 202.21...
Scala vestibuli cochlear implantation in patients with partially ossified cochleas.
Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari
2002-11-01
Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.
Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.
Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric
2015-09-01
Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.
Spiral Form of the Human Cochlea Results from Spatial Constraints.
Pietsch, M; Aguirre Dávila, L; Erfurt, P; Avci, E; Lenarz, T; Kral, A
2017-08-08
The human inner ear has an intricate spiral shape often compared to shells of mollusks, particularly to the nautilus shell. It has inspired many functional hearing theories. The reasons for this complex geometry remain unresolved. We digitized 138 human cochleae at microscopic resolution and observed an astonishing interindividual variability in the shape. A 3D analytical cochlear model was developed that fits the analyzed data with high precision. The cochlear geometry neither matched a proposed function, namely sound focusing similar to a whispering gallery, nor did it have the form of a nautilus. Instead, the innate cochlear blueprint and its actual ontogenetic variants were determined by spatial constraints and resulted from an efficient packing of the cochlear duct within the petrous bone. The analytical model predicts well the individual 3D cochlear geometry from few clinical measures and represents a clinical tool for an individualized approach to neurosensory restoration with cochlear implants.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management. PMID:15247993
The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.
Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2016-01-01
Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.
The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome
Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2016-01-01
Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome. PMID:27376080
Characterizing acoustic shocks in high-performance jet aircraft flyover noise.
Reichman, Brent O; Gee, Kent L; Neilsen, Tracianne B; Downing, J Micah; James, Michael M; Wall, Alan T; McInerny, Sally Anne
2018-03-01
Acoustic shocks have been previously documented in high-amplitude jet noise, including both the near and far fields of military jet aircraft. However, previous investigations into the nature and formation of shocks have historically concentrated on stationary, ground run-up measurements, and previous attempts to connect full-scale ground run-up and flyover measurements have omitted the effect of nonlinear propagation. This paper shows evidence for nonlinear propagation and the presence of acoustic shocks in acoustical measurements of F-35 flyover operations. Pressure waveforms, derivatives, and statistics indicate nonlinear propagation, and the resulting shock formation is significant at high engine powers. Variations due to microphone size, microphone height, and sampling rate are considered, and recommendations for future measurements are made. Metrics indicating nonlinear propagation are shown to be influenced by changes in sampling rate and microphone size, and exhibit less variation due to microphone height.
Electronic filters, hearing aids and methods
NASA Technical Reports Server (NTRS)
Engebretson, A. Maynard (Inventor)
1995-01-01
An electronic filter for an electroacoustic system. The system has a microphone for generating an electrical output from external sounds and an electrically driven transducer for emitting sound. Some of the sound emitted by the transducer returns to the microphone means to add a feedback contribution to its electrical output. The electronic filter includes a first circuit for electronic processing of the electrical output of the microphone to produce a first signal. An adaptive filter, interconnected with the first circuit, performs electronic processing of the first signal to produce an adaptive output to the first circuit to substantially offset the feedback contribution in the electrical output of the microphone, and the adaptive filter includes means for adapting only in response to polarities of signals supplied to and from the first circuit. Other electronic filters for hearing aids, public address systems and other electroacoustic systems, as well as such systems and methods of operating them are also disclosed.
Electronic filters, hearing aids and methods
NASA Technical Reports Server (NTRS)
Engebretson, A. Maynard (Inventor); O'Connell, Michael P. (Inventor); Zheng, Baohua (Inventor)
1991-01-01
An electronic filter for an electroacoustic system. The system has a microphone for generating an electrical output from external sounds and an electrically driven transducer for emitting sound. Some of the sound emitted by the transducer returns to the microphone means to add a feedback contribution to its electical output. The electronic filter includes a first circuit for electronic processing of the electrical output of the microphone to produce a filtered signal. An adaptive filter, interconnected with the first circuit, performs electronic processing of the filtered signal to produce an adaptive output to the first circuit to substantially offset the feedback contribution in the electrical output of the microphone, and the adaptive filter includes means for adapting only in response to polarities of signals supplied to and from the first circuit. Other electronic filters for hearing aids, public address systems and other electroacoustic systems, as well as such systems, and methods of operating them are also disclosed.
Huang, Chien-Hsin; Lee, Chien-Hsing; Hsieh, Tsung-Min; Tsao, Li-Chi; Wu, Shaoyi; Liou, Jhyy-Cheng; Wang, Ming-Yi; Chen, Li-Che; Yip, Ming-Chuen; Fang, Weileun
2011-01-01
This study reports a CMOS-MEMS condenser microphone implemented using the standard thin film stacking of 0.35 μm UMC CMOS 3.3/5.0 V logic process, and followed by post-CMOS micromachining steps without introducing any special materials. The corrugated diaphragm for the microphone is designed and implemented using the metal layer to reduce the influence of thin film residual stresses. Moreover, a silicon substrate is employed to increase the stiffness of the back-plate. Measurements show the sensitivity of microphone is −42 ± 3 dBV/Pa at 1 kHz (the reference sound-level is 94 dB) under 6 V pumping voltage, the frequency response is 100 Hz–10 kHz, and the S/N ratio >55 dB. It also has low power consumption of less than 200 μA, and low distortion of less than 1% (referred to 100 dB). PMID:22163953
Deconvolution Methods and Systems for the Mapping of Acoustic Sources from Phased Microphone Arrays
NASA Technical Reports Server (NTRS)
Humphreys, Jr., William M. (Inventor); Brooks, Thomas F. (Inventor)
2012-01-01
Mapping coherent/incoherent acoustic sources as determined from a phased microphone array. A linear configuration of equations and unknowns are formed by accounting for a reciprocal influence of one or more cross-beamforming characteristics thereof at varying grid locations among the plurality of grid locations. An equation derived from the linear configuration of equations and unknowns can then be iteratively determined. The equation can be attained by the solution requirement of a constraint equivalent to the physical assumption that the coherent sources have only in phase coherence. The size of the problem may then be reduced using zoning methods. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with a phased microphone array (microphones arranged in an optimized grid pattern including a plurality of grid locations) in order to compile an output presentation thereof, thereby removing beamforming characteristics from the resulting output presentation.
Non-Intrusive Sensor for In-Situ Measurement of Recession Rate of Ablative and Eroding Materials
NASA Technical Reports Server (NTRS)
Papadopoulos, George (Inventor); Tiliakos, Nicholas (Inventor); Thomson, Clint (Inventor); Benel, Gabriel (Inventor)
2014-01-01
A non-intrusive sensor for in-situ measurement of recession rate of heat shield ablatives. An ultrasonic wave source is carried in the housing. A microphone is also carried in the housing, for collecting the reflected ultrasonic waves from an interface surface of the ablative material. A time phasing control circuit is also included for time-phasing the ultrasonic wave source so that the waves reflected from the interface surface of the ablative material focus on the microphone, to maximize the acoustic pressure detected by the microphone and to mitigate acoustic velocity variation effects through the material through a de-coupling process that involves a software algorithm. A software circuit for computing the location off of which the ultrasonic waves scattered to focus back at the microphone is also included, so that the recession rate of the heat shield ablative may be monitored in real-time through the scan-focus approach.
Deconvolution methods and systems for the mapping of acoustic sources from phased microphone arrays
NASA Technical Reports Server (NTRS)
Brooks, Thomas F. (Inventor); Humphreys, Jr., William M. (Inventor)
2010-01-01
A method and system for mapping acoustic sources determined from a phased microphone array. A plurality of microphones are arranged in an optimized grid pattern including a plurality of grid locations thereof. A linear configuration of N equations and N unknowns can be formed by accounting for a reciprocal influence of one or more beamforming characteristics thereof at varying grid locations among the plurality of grid locations. A full-rank equation derived from the linear configuration of N equations and N unknowns can then be iteratively determined. A full-rank can be attained by the solution requirement of the positivity constraint equivalent to the physical assumption of statically independent noise sources at each N location. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with the phased microphone array in order to compile an output presentation thereof, thereby removing the beamforming characteristics from the resulting output presentation.
Acoustic Location of Lightning Using Interferometric Techniques
NASA Astrophysics Data System (ADS)
Erives, H.; Arechiga, R. O.; Stock, M.; Lapierre, J. L.; Edens, H. E.; Stringer, A.; Rison, W.; Thomas, R. J.
2013-12-01
Acoustic arrays have been used to accurately locate thunder sources in lightning flashes. The acoustic arrays located around the Magdalena mountains of central New Mexico produce locations which compare quite well with source locations provided by the New Mexico Tech Lightning Mapping Array. These arrays utilize 3 outer microphones surrounding a 4th microphone located at the center, The location is computed by band-passing the signal to remove noise, and then computing the cross correlating the outer 3 microphones with respect the center reference microphone. While this method works very well, it works best on signals with high signal to noise ratios; weaker signals are not as well located. Therefore, methods are being explored to improve the location accuracy and detection efficiency of the acoustic location systems. The signal received by acoustic arrays is strikingly similar to th signal received by radio frequency interferometers. Both acoustic location systems and radio frequency interferometers make coherent measurements of a signal arriving at a number of closely spaced antennas. And both acoustic and interferometric systems then correlate these signals between pairs of receivers to determine the direction to the source of the received signal. The primary difference between the two systems is the velocity of propagation of the emission, which is much slower for sound. Therefore, the same frequency based techniques that have been used quite successfully with radio interferometers should be applicable to acoustic based measurements as well. The results presented here are comparisons between the location results obtained with current cross correlation method and techniques developed for radio frequency interferometers applied to acoustic signals. The data were obtained during the summer 2013 storm season using multiple arrays sensitive to both infrasonic frequency and audio frequency acoustic emissions from lightning. Preliminary results show that interferometric techniques have good potential for improving the lightning location accuracy and detection efficiency of acoustic arrays.
Banakis Hartl, Renee M; Mattingly, Jameson K; Greene, Nathaniel T; Jenkins, Herman A; Cass, Stephen P; Tollin, Daniel J
2016-10-01
A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative ABG remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative ABG. Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with previous literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable after electrode placement. Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity.
Spatial selectivity and binaural responses in the inferior colliculus of the great horned owl.
Volman, S F; Konishi, M
1989-09-01
In this study we have investigated the processing of auditory cues for sound localization in the great horned owl (Bubo virginianus). Previous studies have shown that the barn owl, whose ears are asymmetrically oriented in the vertical plane, has a 2-dimensional, topographic representation of auditory space in the external division of the inferior colliculus (ICx). As in the barn owl, the great horned owl's ICx is anatomically distinct and projects to the optic tectum. Neurons in ICx respond over only a small range of azimuths (mean = 32 degrees), and azimuth is topographically mapped. In contrast to the barn owl, the great horned owl has bilaterally symmetrical ears and its receptive fields are not restricted in elevation. The binaural cues available for sound localization were measured both with cochlear microphonic recordings and with a microphone attached to a probe tube in the auditory canal. Interaural time disparity (ITD) varied monotonically with azimuth. Interaural intensity differences (IID) also changed with azimuth, but the largest IIDs were less than 15 dB, and the variation was not monotonic. Neither ITD nor IID varied systematically with changes in the vertical position of a sound source. We used dichotic stimulation to determine the sensitivity of ICx neurons to these binaural cues. Best ITD of ICx units was topographically mapped and strongly correlated with receptive-field azimuth. The width of ITD tuning curves, measured at 50% of the maximum response, averaged 72 microseconds. All ICx neurons responded only to binaural stimulation and had nonmonotonic IID tuning curves. Best IID was weakly, but significantly, correlated with best ITD (r = 0.39, p less than 0.05). The IID tuning curves, however, were broad (mean 50% width = 24 dB), and 67% of the units had best IIDs within 5 dB of 0 dB IID. ITD tuning was sensitive to variations in IID in the direction opposite to that expected for time-intensity trading, but the magnitude of this effect was only 1.5 microseconds/dB IID. We conclude that, in the great horned owl, the spatial selectivity of ICx neurons arises primarily from their ITD tuning. Except for the absence of elevation selectivity and the narrow range of best IIDs, ICx in the great horned owl appears to be organized much the same as in the barn owl.