Sample records for coding svc extension

  1. Video traffic characteristics of modern encoding standards: H.264/AVC with SVC and MVC extensions and H.265/HEVC.

    PubMed

    Seeling, Patrick; Reisslein, Martin

    2014-01-01

    Video encoding for multimedia services over communication networks has significantly advanced in recent years with the development of the highly efficient and flexible H.264/AVC video coding standard and its SVC extension. The emerging H.265/HEVC video coding standard as well as 3D video coding further advance video coding for multimedia communications. This paper first gives an overview of these new video coding standards and then examines their implications for multimedia communications by studying the traffic characteristics of long videos encoded with the new coding standards. We review video coding advances from MPEG-2 and MPEG-4 Part 2 to H.264/AVC and its SVC and MVC extensions as well as H.265/HEVC. For single-layer (nonscalable) video, we compare H.265/HEVC and H.264/AVC in terms of video traffic and statistical multiplexing characteristics. Our study is the first to examine the H.265/HEVC traffic variability for long videos. We also illustrate the video traffic characteristics and statistical multiplexing of scalable video encoded with the SVC extension of H.264/AVC as well as 3D video encoded with the MVC extension of H.264/AVC.

  2. Video Traffic Characteristics of Modern Encoding Standards: H.264/AVC with SVC and MVC Extensions and H.265/HEVC

    PubMed Central

    2014-01-01

    Video encoding for multimedia services over communication networks has significantly advanced in recent years with the development of the highly efficient and flexible H.264/AVC video coding standard and its SVC extension. The emerging H.265/HEVC video coding standard as well as 3D video coding further advance video coding for multimedia communications. This paper first gives an overview of these new video coding standards and then examines their implications for multimedia communications by studying the traffic characteristics of long videos encoded with the new coding standards. We review video coding advances from MPEG-2 and MPEG-4 Part 2 to H.264/AVC and its SVC and MVC extensions as well as H.265/HEVC. For single-layer (nonscalable) video, we compare H.265/HEVC and H.264/AVC in terms of video traffic and statistical multiplexing characteristics. Our study is the first to examine the H.265/HEVC traffic variability for long videos. We also illustrate the video traffic characteristics and statistical multiplexing of scalable video encoded with the SVC extension of H.264/AVC as well as 3D video encoded with the MVC extension of H.264/AVC. PMID:24701145

  3. Optimized bit extraction using distortion modeling in the scalable extension of H.264/AVC.

    PubMed

    Maani, Ehsan; Katsaggelos, Aggelos K

    2009-09-01

    The newly adopted scalable extension of H.264/AVC video coding standard (SVC) demonstrates significant improvements in coding efficiency in addition to an increased degree of supported scalability relative to the scalable profiles of prior video coding standards. Due to the complicated hierarchical prediction structure of the SVC and the concept of key pictures, content-aware rate adaptation of SVC bit streams to intermediate bit rates is a nontrivial task. The concept of quality layers has been introduced in the design of the SVC to allow for fast content-aware prioritized rate adaptation. However, existing quality layer assignment methods are suboptimal and do not consider all network abstraction layer (NAL) units from different layers for the optimization. In this paper, we first propose a technique to accurately and efficiently estimate the quality degradation resulting from discarding an arbitrary number of NAL units from multiple layers of a bitstream by properly taking drift into account. Then, we utilize this distortion estimation technique to assign quality layers to NAL units for a more efficient extraction. Experimental results show that a significant gain can be achieved by the proposed scheme.

  4. Real-time video streaming using H.264 scalable video coding (SVC) in multihomed mobile networks: a testbed approach

    NASA Astrophysics Data System (ADS)

    Nightingale, James; Wang, Qi; Grecos, Christos

    2011-03-01

    Users of the next generation wireless paradigm known as multihomed mobile networks expect satisfactory quality of service (QoS) when accessing streamed multimedia content. The recent H.264 Scalable Video Coding (SVC) extension to the Advanced Video Coding standard (AVC), offers the facility to adapt real-time video streams in response to the dynamic conditions of multiple network paths encountered in multihomed wireless mobile networks. Nevertheless, preexisting streaming algorithms were mainly proposed for AVC delivery over multipath wired networks and were evaluated by software simulation. This paper introduces a practical, hardware-based testbed upon which we implement and evaluate real-time H.264 SVC streaming algorithms in a realistic multihomed wireless mobile networks environment. We propose an optimised streaming algorithm with multi-fold technical contributions. Firstly, we extended the AVC packet prioritisation schemes to reflect the three-dimensional granularity of SVC. Secondly, we designed a mechanism for evaluating the effects of different streamer 'read ahead window' sizes on real-time performance. Thirdly, we took account of the previously unconsidered path switching and mobile networks tunnelling overheads encountered in real-world deployments. Finally, we implemented a path condition monitoring and reporting scheme to facilitate the intelligent path switching. The proposed system has been experimentally shown to offer a significant improvement in PSNR of the received stream compared with representative existing algorithms.

  5. SCTP as scalable video coding transport

    NASA Astrophysics Data System (ADS)

    Ortiz, Jordi; Graciá, Eduardo Martínez; Skarmeta, Antonio F.

    2013-12-01

    This study presents an evaluation of the Stream Transmission Control Protocol (SCTP) for the transport of the scalable video codec (SVC), proposed by MPEG as an extension to H.264/AVC. Both technologies fit together properly. On the one hand, SVC permits to split easily the bitstream into substreams carrying different video layers, each with different importance for the reconstruction of the complete video sequence at the receiver end. On the other hand, SCTP includes features, such as the multi-streaming and multi-homing capabilities, that permit to transport robustly and efficiently the SVC layers. Several transmission strategies supported on baseline SCTP and its concurrent multipath transfer (CMT) extension are compared with the classical solutions based on the Transmission Control Protocol (TCP) and the Realtime Transmission Protocol (RTP). Using ns-2 simulations, it is shown that CMT-SCTP outperforms TCP and RTP in error-prone networking environments. The comparison is established according to several performance measurements, including delay, throughput, packet loss, and peak signal-to-noise ratio of the received video.

  6. Dynamic full-scalability conversion in scalable video coding

    NASA Astrophysics Data System (ADS)

    Lee, Dong Su; Bae, Tae Meon; Thang, Truong Cong; Ro, Yong Man

    2007-02-01

    For outstanding coding efficiency with scalability functions, SVC (Scalable Video Coding) is being standardized. SVC can support spatial, temporal and SNR scalability and these scalabilities are useful to provide a smooth video streaming service even in a time varying network such as a mobile environment. But current SVC is insufficient to support dynamic video conversion with scalability, thereby the adaptation of bitrate to meet a fluctuating network condition is limited. In this paper, we propose dynamic full-scalability conversion methods for QoS adaptive video streaming in SVC. To accomplish full scalability dynamic conversion, we develop corresponding bitstream extraction, encoding and decoding schemes. At the encoder, we insert the IDR NAL periodically to solve the problems of spatial scalability conversion. At the extractor, we analyze the SVC bitstream to get the information which enable dynamic extraction. Real time extraction is achieved by using this information. Finally, we develop the decoder so that it can manage the changing scalability. Experimental results showed that dynamic full-scalability conversion was verified and it was necessary for time varying network condition.

  7. Integer-Linear-Programing Optimization in Scalable Video Multicast with Adaptive Modulation and Coding in Wireless Networks

    PubMed Central

    Lee, Chaewoo

    2014-01-01

    The advancement in wideband wireless network supports real time services such as IPTV and live video streaming. However, because of the sharing nature of the wireless medium, efficient resource allocation has been studied to achieve a high level of acceptability and proliferation of wireless multimedia. Scalable video coding (SVC) with adaptive modulation and coding (AMC) provides an excellent solution for wireless video streaming. By assigning different modulation and coding schemes (MCSs) to video layers, SVC can provide good video quality to users in good channel conditions and also basic video quality to users in bad channel conditions. For optimal resource allocation, a key issue in applying SVC in the wireless multicast service is how to assign MCSs and the time resources to each SVC layer in the heterogeneous channel condition. We formulate this problem with integer linear programming (ILP) and provide numerical results to show the performance under 802.16 m environment. The result shows that our methodology enhances the overall system throughput compared to an existing algorithm. PMID:25276862

  8. Prediction of chemical biodegradability using support vector classifier optimized with differential evolution.

    PubMed

    Cao, Qi; Leung, K M

    2014-09-22

    Reliable computer models for the prediction of chemical biodegradability from molecular descriptors and fingerprints are very important for making health and environmental decisions. Coupling of the differential evolution (DE) algorithm with the support vector classifier (SVC) in order to optimize the main parameters of the classifier resulted in an improved classifier called the DE-SVC, which is introduced in this paper for use in chemical biodegradability studies. The DE-SVC was applied to predict the biodegradation of chemicals on the basis of extensive sample data sets and known structural features of molecules. Our optimization experiments showed that DE can efficiently find the proper parameters of the SVC. The resulting classifier possesses strong robustness and reliability compared with grid search, genetic algorithm, and particle swarm optimization methods. The classification experiments conducted here showed that the DE-SVC exhibits better classification performance than models previously used for such studies. It is a more effective and efficient prediction model for chemical biodegradability.

  9. Superior Vena Cava as Gateway to Heart: Metastatic Breast Carcinoma Causing Ball in a Loop Metastasis to Right Atrium.

    PubMed

    Sandhu, Harpreet Singh; Mahendrakar, Sampath Kumar Mahadevappa; Ladhani, Sulaiman Sadruddin; Khan, Azizullah Hafizullah; Loya, Yunus Shafi

    2017-07-01

    Breast carcinoma is the most common invasive cancer in women worldwide. It metastasizes commonly to bone, lungs, regional lymph nodes and brain. Cardiac metastasis of lung and breast cancers is a known but rare complication of advanced disease with tumour metastasising to pericardium via the locoregional lymphatic system. Here we present a case of 59-year-old female presenting with right upper limb oedema, facial puffiness and features of Superior Vena Cava (SVC) syndrome 15 years after mastectomy and adjuvant chemotherapy, radiotherapy for carcinoma of the right breast. Further evaluation revealed extensive thrombus invading the right internal jugular vein, subclavian vein, SVC with intraluminal extension into right atrium causing ball in a loop obstruction at tricuspid valve. Whole body Positron emission tomography scan confirmed the diagnosis of extensive metastatic disease and patient was managed on palliative therapy. Haematogenous spread and intraluminal growth of metastatic deposits from breast carcinoma 15 years ago is rare and clinical presentation as SVC obstruction has not been reported in our review of literature.

  10. Design of an H.264/SVC resilient watermarking scheme

    NASA Astrophysics Data System (ADS)

    Van Caenegem, Robrecht; Dooms, Ann; Barbarien, Joeri; Schelkens, Peter

    2010-01-01

    The rapid dissemination of media technologies has lead to an increase of unauthorized copying and distribution of digital media. Digital watermarking, i.e. embedding information in the multimedia signal in a robust and imperceptible manner, can tackle this problem. Recently, there has been a huge growth in the number of different terminals and connections that can be used to consume multimedia. To tackle the resulting distribution challenges, scalable coding is often employed. Scalable coding allows the adaptation of a single bit-stream to varying terminal and transmission characteristics. As a result of this evolution, watermarking techniques that are robust against scalable compression become essential in order to control illegal copying. In this paper, a watermarking technique resilient against scalable video compression using the state-of-the-art H.264/SVC codec is therefore proposed and evaluated.

  11. Bandwidth auction for SVC streaming in dynamic multi-overlay

    NASA Astrophysics Data System (ADS)

    Xiong, Yanting; Zou, Junni; Xiong, Hongkai

    2010-07-01

    In this paper, we study the optimal bandwidth allocation for scalable video coding (SVC) streaming in multiple overlays. We model the whole bandwidth request and distribution process as a set of decentralized auction games between the competing peers. For the upstream peer, a bandwidth allocation mechanism is introduced to maximize the aggregate revenue. For the downstream peer, a dynamic bidding strategy is proposed. It achieves maximum utility and efficient resource usage by collaborating with a content-aware layer dropping/adding strategy. Also, the convergence of the proposed auction games is theoretically proved. Experimental results show that the auction strategies can adapt to dynamic join of competing peers and video layers.

  12. Apply network coding for H.264/SVC multicasting

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Kuo, C.-C. Jay

    2008-08-01

    In a packet erasure network environment, video streaming benefits from error control in two ways to achieve graceful degradation. The first approach is application-level (or the link-level) forward error-correction (FEC) to provide erasure protection. The second error control approach is error concealment at the decoder end to compensate lost packets. A large amount of research work has been done in the above two areas. More recently, network coding (NC) techniques have been proposed for efficient data multicast over networks. It was shown in our previous work that multicast video streaming benefits from NC for its throughput improvement. An algebraic model is given to analyze the performance in this work. By exploiting the linear combination of video packets along nodes in a network and the SVC video format, the system achieves path diversity automatically and enables efficient video delivery to heterogeneous receivers in packet erasure channels. The application of network coding can protect video packets against the erasure network environment. However, the rank defficiency problem of random linear network coding makes the error concealment inefficiently. It is shown by computer simulation that the proposed NC video multicast scheme enables heterogenous receiving according to their capacity constraints. But it needs special designing to improve the video transmission performance when applying network coding.

  13. Downhill oesophageal variceal bleeding: A rare complication in Behçet's disease-related superior vena cava syndrome.

    PubMed

    Ennaifer, Rym; B'chir Hamzaoui, Saloua; Larbi, Thara; Romdhane, Hayfa; Abdallah, Maya; Bel Hadj, Najet; M'rad, Sander

    2015-03-01

    Behçet's disease (BD) is a multisystemic disorder that involves vessels of all sizes. Superior vena cava (SVC) thrombosis is a rare complication that can lead to the development of various collateral pathways. A 31-year-old man presented with SVC syndrome. He had a history of recurrent genital aphthosis. Computed tomography revealed extensive thrombosis of the right internal jugular, axillary, and subclavian veins with collateral circulation. The patient was diagnosed with BD, and he was started on anticoagulation and immunosuppressive therapy. One week later, he presented with haematemesis. Upper gastrointestinal endoscopy disclosed varices in the upper third of the oesophagus with stigmata of recent bleeding. Portal hypertension was ruled out. Anticoagulation therapy was discontinued. He was discharged on immunosuppressive therapy. Bleeding from downhill oesophageal varices should be suspected in any patient presenting with upper gastrointestinal bleeding and a history of SVC syndrome due to BD. Copyright © 2015 Arab Journal of Gastroenterology. Published by Elsevier B.V. All rights reserved.

  14. Evaluation of in-network adaptation of scalable high efficiency video coding (SHVC) in mobile environments

    NASA Astrophysics Data System (ADS)

    Nightingale, James; Wang, Qi; Grecos, Christos; Goma, Sergio

    2014-02-01

    High Efficiency Video Coding (HEVC), the latest video compression standard (also known as H.265), can deliver video streams of comparable quality to the current H.264 Advanced Video Coding (H.264/AVC) standard with a 50% reduction in bandwidth. Research into SHVC, the scalable extension to the HEVC standard, is still in its infancy. One important area for investigation is whether, given the greater compression ratio of HEVC (and SHVC), the loss of packets containing video content will have a greater impact on the quality of delivered video than is the case with H.264/AVC or its scalable extension H.264/SVC. In this work we empirically evaluate the layer-based, in-network adaptation of video streams encoded using SHVC in situations where dynamically changing bandwidths and datagram loss ratios require the real-time adaptation of video streams. Through the use of extensive experimentation, we establish a comprehensive set of benchmarks for SHVC-based highdefinition video streaming in loss prone network environments such as those commonly found in mobile networks. Among other results, we highlight that packet losses of only 1% can lead to a substantial reduction in PSNR of over 3dB and error propagation in over 130 pictures following the one in which the loss occurred. This work would be one of the earliest studies in this cutting-edge area that reports benchmark evaluation results for the effects of datagram loss on SHVC picture quality and offers empirical and analytical insights into SHVC adaptation to lossy, mobile networking conditions.

  15. Fast bi-directional prediction selection in H.264/MPEG-4 AVC temporal scalable video coding.

    PubMed

    Lin, Hung-Chih; Hang, Hsueh-Ming; Peng, Wen-Hsiao

    2011-12-01

    In this paper, we propose a fast algorithm that efficiently selects the temporal prediction type for the dyadic hierarchical-B prediction structure in the H.264/MPEG-4 temporal scalable video coding (SVC). We make use of the strong correlations in prediction type inheritance to eliminate the superfluous computations for the bi-directional (BI) prediction in the finer partitions, 16×8/8×16/8×8 , by referring to the best temporal prediction type of 16 × 16. In addition, we carefully examine the relationship in motion bit-rate costs and distortions between the BI and the uni-directional temporal prediction types. As a result, we construct a set of adaptive thresholds to remove the unnecessary BI calculations. Moreover, for the block partitions smaller than 8 × 8, either the forward prediction (FW) or the backward prediction (BW) is skipped based upon the information of their 8 × 8 partitions. Hence, the proposed schemes can efficiently reduce the extensive computational burden in calculating the BI prediction. As compared to the JSVM 9.11 software, our method saves the encoding time from 48% to 67% for a large variety of test videos over a wide range of coding bit-rates and has only a minor coding performance loss. © 2011 IEEE

  16. A “Train-Track” Technique in Anatomic Reconstruction of SVC Bifurcation Complicated by Cardiac Tamponade: An Introspection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karuppasamy, Karunakaravel, E-mail: karuppk@ccf.org; Al-Natour, Mohammed, E-mail: mnatour85@msn.com; Gurajala, Ram Kishore, E-mail: gurajar@ccf.org

    This report describes a stenting technique used to anatomically reconstruct superior vena cava (SVC) bifurcation in a patient with benign SVC syndrome. After recanalizing the SVC bifurcation, we exchanged two 0.035-in. wires for two 0.018-in. wires, deployed the SVC stent over these two wires (“train-track” technique), and stented each innominate vein over one wire. However, our decisions to recanalize both innominate veins, use the “buddy-wire” technique for SVC dilation, and dilate the SVC to 16 mm before stent deployment likely contributed to SVC tear, which was managed by resuscitation, SVC stent placement, and pericardial drainage. Here, we describe the steps ofmore » the train-track technique, which can be adopted to reconstruct other bifurcations; we also discuss the controversial aspects of this case.« less

  17. Defibrillation efficacy of different electrode placements in a human thorax model.

    PubMed

    de Jongh, A L; Entcheva, E G; Replogle, J A; Booker, R S; Kenknight, B H; Claydon, F J

    1999-01-01

    The objective of this study was to measure the defibrillation threshold (DFT) associated with different electrode placements using a three-dimensional anatomically realistic finite element model of the human thorax. Coil electrodes (Endotak DSP, model 125, Guidant/CPI) were placed in the RV apex along the lateral wall (RV), withdrawn 10 mm away from the RV apex along the lateral wall (RVprox), in the RV apex along the anterior septum (RVseptal), and in the SVC. An active pulse generator (can) was placed in the subcutaneous prepectoral space. Five electrode configurations were studied: RV-->SVC, RVprox-->SVC, RVSEPTAL-->SVC, RV-->Can, and RV-->SVC + Can. DFTs are defined as the energy required to produce a potential gradient of at least 5 V/cm in 95% of the ventricular myocardium. DFTs for RV-->SVC, RVprox-->SVC, RVseptal-->SVC, RV-->Can, and RV-->SVC + Can were 10, 16, 7, 9, and 6 J, respectively. The DFTs measured at each configuration fell within one standard deviation of the mean DFTs reported in clinical studies using the Endotak leads. The relative changes in DFT among electrode configurations also compared favorably. This computer model allows measurements of DFT or other defibrillation parameters with several different electrode configurations saving time and cost of clinical studies.

  18. The difference between slow and forced vital capacity increases with increasing body mass index: a paradoxical difference in low and normal body mass indices.

    PubMed

    Fortis, Spyridon; Corazalla, Edward O; Wang, Qi; Kim, Hyun J

    2015-01-01

    Obesity reduces FVC, the most commonly used measurement of vital capacity (VC) and slow VC (SVC). It is unknown whether the difference between SVC and FVC is constant in different body mass indices (BMIs). We hypothesized that the difference between SVC and FVC increases as a function of BMI. We retrospectively reviewed pulmonary function tests (PFTs) that included spirometry and plethysmography and were performed in adults from January 2013 to August 2013. A total of 1,805 PFTs were enrolled. The non-parametric Wilcoxon signed-rank test was used to compare FVC with SVC, and to compare FEV1/FVC with FEV1/SVC ratio. Spearman correlation analysis was used to determine whether BMI has an effect on the discordance between FVC and SVC. Finally, we used the McNemar test for paired binary data to compare the prevalence rate of obstruction when using different measurements of VC. In individuals with BMI < 25 kg/m(2) and no evidence of obstruction in the PFTs, FVC was larger than SVC (P = .03), whereas in overweight and obese individuals, SVC was significantly larger than FVC. The difference between SVC and FVC was positively correlated with BMI (P < .001). One hundred thirty-one patients had a normal FEV1/FVC but low FEV1/SVC ratio. Fifty of these 131 individuals also had a normal FVC; the majority of them (46 of 50) had the PFTs for investigation of respiratory symptoms and had BMI > 25 kg/m(2) (42 of 50). Our results indicate that FVC is larger than SVC in patients with low and normal BMI and no evidence of obstruction in the PFTs, whereas FVC is smaller than SVC in overweight and obese individual. Our findings add to the existing literature that use of FEV1/FVC may lead to underdiagnosis of obstructive airway disease in overweight and obese individuals. Copyright © 2015 by Daedalus Enterprises.

  19. Improving P2P live-content delivery using SVC

    NASA Astrophysics Data System (ADS)

    Schierl, T.; Sánchez, Y.; Hellge, C.; Wiegand, T.

    2010-07-01

    P2P content delivery techniques for video transmission have become of high interest in the last years. With the involvement of client into the delivery process, P2P approaches can significantly reduce the load and cost on servers, especially for popular services. However, previous studies have already pointed out the unreliability of P2P-based live streaming approaches due to peer churn, where peers may ungracefully leave the P2P infrastructure, typically an overlay networks. Peers ungracefully leaving the system cause connection losses in the overlay, which require repair operations. During such repair operations, which typically take a few roundtrip times, no data is received from the lost connection. While taking low delay for fast-channel tune-in into account as a key feature for broadcast-like streaming applications, the P2P live streaming approach can only rely on a certain media pre-buffer during such repair operations. In this paper, multi-tree based Application Layer Multicast as a P2P overlay technique for live streaming is considered. The use of Flow Forwarding (FF), a.k.a. Retransmission, or Forward Error Correction (FEC) in combination with Scalable video Coding (SVC) for concealment during overlay repair operations is shown. Furthermore the benefits of using SVC over the use of AVC single layer transmission are presented.

  20. Managing central venous obstruction in cystic fibrosis recipients--lung transplant considerations.

    PubMed

    Otani, Shinji; Westall, Glen P; Levvey, Bronwyn J; Marasco, Silvana; Lyon, Stuart; Snell, Gregory I

    2015-03-01

    The superior vena cava (SVC) syndrome in cystic fibrosis (CF) patients is rare, but presents unique challenges in the peri-transplant period. We reviewed our experience of SVC syndrome in CF recipients undergoing lung transplantation. This is a retrospective case series from a single center chart-review. SVC obstruction is defined by clinically significant stenosis or obstruction of the SVC as detected by contrast studies. We identified SVC obstruction in seven post-transplant cases and one pre-transplant case. All eight patients had previous or current history of indwelling central venous catheters. Three recipients experienced operative complications. Five of the seven recipients suffered at least one episode of post-operative SVC obstruction or bleeding despite prophylactic anticoagulation. At a median follow-up of 29 months, six of the seven patients transplanted are well. Strategies are available to minimize the risks of intra/peri-operative acute life-threatening SVC obstruction in CF patients. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  1. Assessing consumption of bioactive micro-particles by filter-feeding Asian carp

    USGS Publications Warehouse

    Jensen, Nathan R.; Amberg, Jon J.; Luoma, James A.; Walleser, Liza R.; Gaikowski, Mark P.

    2012-01-01

    Silver carp Hypophthalmichthys molitrix (SVC) and bighead carp H. nobilis (BHC) have impacted waters in the US since their escape. Current chemical controls for aquatic nuisance species are non-selective. Development of a bioactive micro-particle that exploits filter-feeding habits of SVC or BHC could result in a new control tool. It is not fully understood if SVC or BHC will consume bioactive micro-particles. Two discrete trials were performed to: 1) evaluate if SVC and BHC consume the candidate micro-particle formulation; 2) determine what size they consume; 3) establish methods to evaluate consumption of filter-feeders for future experiments. Both SVC and BHC were exposed to small (50-100 μm) and large (150-200 μm) micro-particles in two 24-h trials. Particles in water were counted electronically and manually (microscopy). Particles on gill rakers were counted manually and intestinal tracts inspected for the presence of micro-particles. In Trial 1, both manual and electronic count data confirmed reductions of both size particles; SVC appeared to remove more small particles than large; more BHC consumed particles; SVC had fewer overall particles in their gill rakers than BHC. In Trial 2, electronic counts confirmed reductions of both size particles; both SVC and BHC consumed particles, yet more SVC consumed micro-particles compared to BHC. Of the fish that ate micro-particles, SVC consumed more than BHC. It is recommended to use multiple metrics to assess consumption of candidate micro-particles by filter-feeders when attempting to distinguish differential particle consumption. This study has implications for developing micro-particles for species-specific delivery of bioactive controls to help fisheries, provides some methods for further experiments with bioactive micro-particles, and may also have applications in aquaculture.

  2. Bias and Stability of Single Variable Classifiers for Feature Ranking and Selection

    PubMed Central

    Fakhraei, Shobeir; Soltanian-Zadeh, Hamid; Fotouhi, Farshad

    2014-01-01

    Feature rankings are often used for supervised dimension reduction especially when discriminating power of each feature is of interest, dimensionality of dataset is extremely high, or computational power is limited to perform more complicated methods. In practice, it is recommended to start dimension reduction via simple methods such as feature rankings before applying more complex approaches. Single Variable Classifier (SVC) ranking is a feature ranking based on the predictive performance of a classifier built using only a single feature. While benefiting from capabilities of classifiers, this ranking method is not as computationally intensive as wrappers. In this paper, we report the results of an extensive study on the bias and stability of such feature ranking method. We study whether the classifiers influence the SVC rankings or the discriminative power of features themselves has a dominant impact on the final rankings. We show the common intuition of using the same classifier for feature ranking and final classification does not always result in the best prediction performance. We then study if heterogeneous classifiers ensemble approaches provide more unbiased rankings and if they improve final classification performance. Furthermore, we calculate an empirical prediction performance loss for using the same classifier in SVC feature ranking and final classification from the optimal choices. PMID:25177107

  3. Bias and Stability of Single Variable Classifiers for Feature Ranking and Selection.

    PubMed

    Fakhraei, Shobeir; Soltanian-Zadeh, Hamid; Fotouhi, Farshad

    2014-11-01

    Feature rankings are often used for supervised dimension reduction especially when discriminating power of each feature is of interest, dimensionality of dataset is extremely high, or computational power is limited to perform more complicated methods. In practice, it is recommended to start dimension reduction via simple methods such as feature rankings before applying more complex approaches. Single Variable Classifier (SVC) ranking is a feature ranking based on the predictive performance of a classifier built using only a single feature. While benefiting from capabilities of classifiers, this ranking method is not as computationally intensive as wrappers. In this paper, we report the results of an extensive study on the bias and stability of such feature ranking method. We study whether the classifiers influence the SVC rankings or the discriminative power of features themselves has a dominant impact on the final rankings. We show the common intuition of using the same classifier for feature ranking and final classification does not always result in the best prediction performance. We then study if heterogeneous classifiers ensemble approaches provide more unbiased rankings and if they improve final classification performance. Furthermore, we calculate an empirical prediction performance loss for using the same classifier in SVC feature ranking and final classification from the optimal choices.

  4. CMMI for Services (CMMI-SVC) Overview Presentation

    DTIC Science & Technology

    2008-10-01

    processes 5 CMMI for Services (CMMI-SVC) Overview Forrester, 2008 © 2008 Carnegie Mellon University Why is the CMMI-SVC needed? Service providers...Project Management (IPM) • Project Monitoring and Control (PMC) • Project Planning (PP) • Requirements Management (REQM) • Risk Management (RSKM...contact, and your resume reflecting 5 or more years of service experience to cmmi- svc-app@sei.cmu.edu . 2. Fill out the sponsorship form here: http

  5. Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM

    PubMed Central

    Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi

    2017-01-01

    Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027

  6. The perfusion index derived from a pulse oximeter for predicting low superior vena cava flow in very low birth weight infants.

    PubMed

    Takahashi, S; Kakiuchi, S; Nanba, Y; Tsukamoto, K; Nakamura, T; Ito, Y

    2010-04-01

    Superior vena cava (SVC) flow is used as an index for evaluating systemic blood flow in neonates. Thus far, several reports have shown that low SVC flow is a risk factor for intraventricular hemorrhage (IVH) in the preterm infant. Therefore, it is likely to be a useful index in the management of the preterm infant. The perfusion index (PI) derived from a pulse oximeter is a marker that allows noninvasive and continuous monitoring of peripheral perfusion. The objective of this paper was to determine the accuracy of the PI for detecting low SVC flow in very low birth weight infants born before 32 weeks of gestation. We studied the correlation between PI and SVC flow 0 to 72 h after birth in very low birth weight infants born before 32 weeks of gestation. The best cut-off value for low SVC flow was calculated from the respective receiver-operating characteristic curves. A positive correlation was found between the PI and SVC flow (r=0.509, P<0.001). The best cut-off value for the PI to detect low SVC flow was 0.44 (sensitivity 87.5%, specificity 86.3%, positive predictive value 38.9%, negative predictive value 98.6%). This study found that the PI was associated with SVC flow, and it was a useful index for detecting low SVC flow in very low birth weight infants born before 32 weeks of gestation. Therefore, use of the PI should be evaluated in the cardiovascular management of the preterm infant.

  7. Diagnostics of Loss of Coolant Accidents Using SVC and GMDH Models

    NASA Astrophysics Data System (ADS)

    Lee, Sung Han; No, Young Gyu; Na, Man Gyun; Ahn, Kwang-Il; Park, Soo-Yong

    2011-02-01

    As a means of effectively managing severe accidents at nuclear power plants, it is important to identify and diagnose accident initiating events within a short time interval after the accidents by observing the major measured signals. The main objective of this study was to diagnose loss of coolant accidents (LOCAs) using artificial intelligence techniques, such as SVC (support vector classification) and GMDH (group method of data handling). In this study, the methodologies of SVC and GMDH models were utilized to discover the break location and estimate the break size of the LOCA, respectively. The 300 accident simulation data (based on MAAP4) were used to develop the SVC and GMDH models, and the 33 test data sets were used to independently confirm whether or not the SVC and GMDH models work well. The measured signals from the reactor coolant system, steam generators, and containment at a nuclear power plant were used as inputs to the models, and the 60 sec time-integrated values of the input signals were used as inputs into the SVC and GMDH models. The simulation results confirmed that the proposed SVC model can identify the break location and the proposed GMDH models can estimate the break size accurately. In addition, even if the measurement errors exist and safety systems actuate, the proposed SVC and GMDH models can discover the break locations without a misclassification and accurately estimate the break size.

  8. Endovascular recanalization of a port catheter-associated superior vena cava syndrome.

    PubMed

    Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter

    2015-01-01

    Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.

  9. Bleeding 'downhill' esophageal varices associated with benign superior vena cava obstruction: case report and literature review.

    PubMed

    Loudin, Michael; Anderson, Sharon; Schlansky, Barry

    2016-10-24

    Proximal or 'downhill' esophageal varices are a rare cause of upper gastrointestinal hemorrhage. Unlike the much more common distal esophageal varices, which are most commonly a result of portal hypertension, downhill esophageal varices result from vascular obstruction of the superior vena cava (SVC). While SVC obstruction is most commonly secondary to malignant causes, our review of the literature suggests that benign causes of SVC obstruction are the most common cause actual bleeding from downhill varices. Given the alternative pathophysiology of downhill varices, they require a unique approach to management. Variceal band ligation may be used to temporize acute variceal bleeding, and should be applied on the proximal end of the varix. Relief of the underlying SVC obstruction is the cornerstone of definitive treatment of downhill varices. A young woman with a benign superior vena cava stenosis due to a tunneled internal jugular vein dialysis catheter presented with hematemesis and melena. Urgent upper endoscopy revealed multiple 'downhill' esophageal varices with stigmata of recent hemorrhage. As there was no active bleeding, no endoscopic intervention was performed. CT angiography demonstrated stenosis of the SVC surrounding the distal tip of her indwelling hemodialysis catheter. The patient underwent balloon angioplasty of the stenotic SVC segment with resolution of her bleeding and clinical stabilization. Downhill esophageal varices are a distinct entity from the more common distal esophageal varices. Endoscopic therapies have a role in temporizing active variceal bleeding, but relief of the underlying SVC obstruction is the cornerstone of treatment and should be pursued as rapidly as possible. It is unknown why benign, as opposed to malignant, causes of SVC obstruction result in bleeding from downhill varices at such a high rate, despite being a less common etiology of SVC obstruction.

  10. Public Evaluation of a Community College.

    ERIC Educational Resources Information Center

    Garner, W. Harold; Shapton, Karen

    A marketing study was conducted in the Sauk Valley College (SVC) Illinois district. This public comprehensive community college conducted a survey to determine public perceptions of the scope and quality of its programs; extent of public involvement with SVC; prospective market for SVC; and primary information sources used by the public concerning…

  11. 9 CFR 93.901 - General restrictions; exceptions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... cultures of SVC virus, preserved SVC virus viral RNA or DNA, tissue samples containing viable SVC virus, or... live fish, fertilized eggs, and gametes are handled as follows: (1) They are maintained under... with paragraph (b)(4) of this section as adequate to prevent the spread within the United States of any...

  12. 9 CFR 93.901 - General restrictions; exceptions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... cultures of SVC virus, preserved SVC virus viral RNA or DNA, tissue samples containing viable SVC virus, or... live fish, fertilized eggs, and gametes are handled as follows: (1) They are maintained under... with paragraph (b)(4) of this section as adequate to prevent the spread within the United States of any...

  13. 9 CFR 93.901 - General restrictions; exceptions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... cultures of SVC virus, preserved SVC virus viral RNA or DNA, tissue samples containing viable SVC virus, or... live fish, fertilized eggs, and gametes are handled as follows: (1) They are maintained under... with paragraph (b)(4) of this section as adequate to prevent the spread within the United States of any...

  14. 9 CFR 93.901 - General restrictions; exceptions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... cultures of SVC virus, preserved SVC virus viral RNA or DNA, tissue samples containing viable SVC virus, or... live fish, fertilized eggs, and gametes are handled as follows: (1) They are maintained under... with paragraph (b)(4) of this section as adequate to prevent the spread within the United States of any...

  15. 9 CFR 93.901 - General restrictions; exceptions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... cultures of SVC virus, preserved SVC virus viral RNA or DNA, tissue samples containing viable SVC virus, or... live fish, fertilized eggs, and gametes are handled as follows: (1) They are maintained under... with paragraph (b)(4) of this section as adequate to prevent the spread within the United States of any...

  16. Spring viraemia of carp (SVC) in the UK: the road to freedom.

    PubMed

    Taylor, N G H; Peeler, E J; Denham, K L; Crane, C N; Thrush, M A; Dixon, P F; Stone, D M; Way, K; Oidtmann, B C

    2013-08-01

    Spring viraemia of carp (SVC) is a disease of international importance that predominantly affects cyprinid fish and can cause significant mortality. In the United Kingdom (UK), SVC was first detected in 1977 with further cases occurring in fisheries, farms, wholesale and retail establishments throughout England and Wales (but not Scotland, where few cyprinid populations exist, nor Northern Ireland where SVC has never been detected) over the subsequent 30 years. Following a control and eradication programme for the disease initiated in 2005, the UK was recognised free of the disease in 2010. This study compiles historic records of SVC cases in England and Wales with a view to understanding its routes of introduction and spread, and assessing the effectiveness of the control and eradication programme in order to improve contingency plans to prevent and control future disease incursions in the cyprinid fish sectors. Between 1977 and 2010 the presence of SVC was confirmed on 108 occasions, with 65 of the cases occurring in sport fisheries and the majority of the remainder occurring in the ornamental fish sector. The study found that throughout the history of SVC in the UK, though cases were widely distributed, their occurrence was sporadic and the virus did not become endemic. All evidence indicates that SVC was not able to persist under UK environmental conditions, suggesting that the majority of cases were a result of new introductions to the UK as opposed to within-country spread. The control and eradication programme adopted in 2005 was highly effective and two years after its implementation cases of SVC ceased. Given the non-persistent nature of the pathogen the most important aspect of the control programme focused on preventing re-introduction of the virus to the UK. Despite the effectiveness of these controls against SVC, this approach is likely to be less effective against more persistent pathogens such as koi herpesvirus, which are likely to require more stringent measures to prevent within-country spread. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  17. Classification of diesel pool refinery streams through near infrared spectroscopy and support vector machines using C-SVC and ν-SVC.

    PubMed

    Alves, Julio Cesar L; Henriques, Claudete B; Poppi, Ronei J

    2014-01-03

    The use of near infrared (NIR) spectroscopy combined with chemometric methods have been widely used in petroleum and petrochemical industry and provides suitable methods for process control and quality control. The algorithm support vector machines (SVM) has demonstrated to be a powerful chemometric tool for development of classification models due to its ability to nonlinear modeling and with high generalization capability and these characteristics can be especially important for treating near infrared (NIR) spectroscopy data of complex mixtures such as petroleum refinery streams. In this work, a study on the performance of the support vector machines algorithm for classification was carried out, using C-SVC and ν-SVC, applied to near infrared (NIR) spectroscopy data of different types of streams that make up the diesel pool in a petroleum refinery: light gas oil, heavy gas oil, hydrotreated diesel, kerosene, heavy naphtha and external diesel. In addition to these six streams, the diesel final blend produced in the refinery was added to complete the data set. C-SVC and ν-SVC classification models with 2, 4, 6 and 7 classes were developed for comparison between its results and also for comparison with the soft independent modeling of class analogy (SIMCA) models results. It is demonstrated the superior performance of SVC models especially using ν-SVC for development of classification models for 6 and 7 classes leading to an improvement of sensitivity on validation sample sets of 24% and 15%, respectively, when compared to SIMCA models, providing better identification of chemical compositions of different diesel pool refinery streams. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Rapid guiding catheter swapping for management of rupture during percutaneous venoplasty for idiopathic occlusion of superior vena cava.

    PubMed

    Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay

    2015-04-01

    Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.

  19. Correlation between Forced Vital Capacity and Slow Vital Capacity for the assessment of respiratory involvement in Amyotrophic Lateral Sclerosis: a prospective study.

    PubMed

    Pinto, Susana; de Carvalho, Mamede

    2017-02-01

    Slow vital capacity (SVC) and forced vital capacity (FVC) are the most frequent used tests evaluating respiratory function in amyotrophic lateral sclerosis (ALS). No previous study has determined their interchangeability. To evaluate SVC-FVC correlation in ALS. Consecutive definite/probable ALS and primary lateral sclerosis (PLS) patients (2000-2014) in whom respiratory tests were performed at baseline/4-6months later were included. All were evaluated with revised ALS functional rating scale, the ALSFRS respiratory (R-subscore) and bulbar subscores, SVC, FVC, maximal inspiratory (MIP) and expiratory (MEP) pressures. SVC-FVC correlation was analysed by Pearson product-moment correlation test. Paired t-test compared baseline/follow-up values. Multilinear regression analysis modelled the relationship between tested variables. We included 592 ALS (332 men, mean onset age 62.6 ± 11.8 years, mean disease duration 15.4 ± 15 months) and 19 PLS (11 men, median age 54 years, median disease duration 5.5 years) patients. SVC and FVC predicted values decreased 2.15%/month and 2.08%/month, respectively. FVC and SVC were strongly correlated. Both were strongly correlated with MIP and MEP and moderately correlated with R-subscore for the all population and spinal-onset patients, but weakly correlated for bulbar-onset patients. FVC and SVC were strongly correlated and declined similarly. This correlation was preserved in bulbar-onset ALS and in spastic PLS patients.

  20. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.

    PubMed

    Charbonneau, Hélène; Riu, Béatrice; Faron, Matthieu; Mari, Arnaud; Kurrek, Matt M; Ruiz, Jean; Geeraerts, Thomas; Fourcade, Olivier; Genestal, Michèle; Silva, Stein

    2014-09-05

    Echocardiographic indices based on respiratory variations of superior and inferior vena cavae diameters (ΔSVC and ΔIVC, respectively) have been proposed as predictors of fluid responsiveness in mechanically ventilated patients, but they have never been compared simultaneously in the same patient sample. The aim of this study was to compare the predictive value of these echocardiographic indices when concomitantly recorded in mechanically ventilated septic patients. Septic shock patients requiring hemodynamic monitoring were prospectively enrolled over a 1-year period in a mixed medical surgical ICU of a university teaching hospital (Toulouse, France). All patients were mechanically ventilated. Predictive indices were obtained by transesophageal and transthoracic echocardiography and were calculated as follows: (Dmax - Dmin)/Dmax for ΔSVC and (Dmax - Dmin)/Dmin for ΔIVC, where Dmax and Dmin are the maximal and minimal diameters of SVC and IVC. Measurements were performed at baseline and after a 7-ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in cardiac index ≥15%) and nonresponders (increase in cardiac index <15%). Among 44 included patients, 26 (59%) patients were responders (R). ΔSVC was significantly more accurate than ΔIVC in predicting fluid responsiveness. The areas under the receiver operating characteristic curves for ΔSVC and ΔIVC regarding assessment of fluid responsiveness were significantly different (0.74 (95% confidence interval (CI): 0.59 to 0.88) and 0.43 (95% CI: 0.25 to 0.61), respectively (P = 0.012)). No significant correlation between ΔSVC and ΔIVC was found (r = 0.005, P = 0.98). The best threshold values for discriminating R from NR was 29% for ΔSVC, with 54% sensitivity and 89% specificity, and 21% for ΔIVC, with 38% sensitivity and 61% specificity. ΔSVC was better than ΔIVC in predicting fluid responsiveness in our cohort. It is worth noting that the sensitivity and specificity values of ΔSVC and ΔIVC for predicting fluid responsiveness were lower than those reported in the literature, highlighting the limits of using these indices in a heterogeneous sample of medical and surgical septic patients.

  1. A simulator tool set for evaluating HEVC/SHVC streaming

    NASA Astrophysics Data System (ADS)

    Al Hadhrami, Tawfik; Nightingale, James; Wang, Qi; Grecos, Christos; Kehtarnavaz, Nasser

    2015-02-01

    Video streaming and other multimedia applications account for an ever increasing proportion of all network traffic. The recent adoption of High Efficiency Video Coding (HEVC) as the H.265 standard provides many opportunities for new and improved services multimedia services and applications in the consumer domain. Since the delivery of version one of H.265, the Joint Collaborative Team on Video Coding have been working towards standardisation of a scalable extension (SHVC) to the H.265 standard and a series of range extensions and new profiles. As these enhancements are added to the standard the range of potential applications and research opportunities will expend. For example the use of video is also growing rapidly in other sectors such as safety, security, defence and health with real-time high quality video transmission playing an important role in areas like critical infrastructure monitoring and disaster management. Each of which may benefit from the application of enhanced HEVC/H.265 and SHVC capabilities. The majority of existing research into HEVC/H.265 transmission has focussed on the consumer domain addressing issues such as broadcast transmission and delivery to mobile devices with the lack of freely available tools widely cited as an obstacle to conducting this type of research. In this paper we present a toolset which facilitates the transmission and evaluation of HEVC/H.265 and SHVC encoded video on the popular open source NCTUns simulator. Our toolset provides researchers with a modular, easy to use platform for evaluating video transmission and adaptation proposals on large scale wired, wireless and hybrid architectures. The toolset consists of pre-processing, transmission, SHVC adaptation and post-processing tools to gather and analyse statistics. It has been implemented using HM15 and SHM5, the latest versions of the HEVC and SHVC reference software implementations to ensure that currently adopted proposals for scalable and range extensions to the standard can be investigated. We demonstrate the effectiveness and usability of our toolset by evaluating SHVC streaming and adaptation to meet terminal constraints and network conditions in a range of wired, wireless, and large scale wireless mesh network scenarios, each of which is designed to simulate a realistic environment. Our results are compared to those for H264/SVC, the scalable extension to the existing H.264/AVC advanced video coding standard.

  2. Experience from the 1st Year running a Massive High Quality Videoconferencing Service for the LHC

    NASA Astrophysics Data System (ADS)

    Fernandes, Joao; Baron, Thomas; Bompastor, Bruno

    2014-06-01

    In the last few years, we have witnessed an explosion of visual collaboration initiatives in the industry. Several advances in video services and also in their underlying infrastructure are currently improving the way people collaborate globally. These advances are creating new usage paradigms: any device in any network can be used to collaborate, in most cases with an overall high quality. To keep apace with this technology progression, the CERN IT Department launched a service based on the Vidyo product. This new service architecture introduces Adaptive Video Layering, which dynamically optimizes the video for each endpoint by leveraging the H.264 Scalable Video Coding (SVC)-based compression technology. It combines intelligent AV routing techniques with the flexibility of H.264 SVC video compression, in order to achieve resilient video collaboration over the Internet, 3G and WiFi. We present an overview of the results that have been achieved after this major change. In particular, the first year of operation of the CERN Vidyo service will be described in terms of performance and scale: The service became part of the daily activity of the LHC collaborations, reaching a monthly usage of more than 3200 meetings with a peak of 750 simultaneous connections. We also present some key features such as the integration with CERN Indico. LHC users can now join a Vidyo meeting either from their personal computer or a CERN videoconference room simply from an Indico event page, with the ease of a single click. The roadmap for future improvements, service extensions and core infrastructure tendencies such as cloud based services and virtualization of system components will also be discussed. Vidyo's strengths allowed us to build a universal service (it is accessible from PCs, but also videoconference rooms, traditional phones, tablets and smartphones), developed with 3 key ideas in mind: ease of use, full integration and high quality.

  3. Vascular anatomy in children with univentricular hearts regarding transcatheter bidirectional Glenn anastomosis.

    PubMed

    Sizarov, Aleksander; Raimondi, Francesca; Bonnet, Damien; Boudjemline, Younes

    2017-04-01

    Transcatheter stent-secured Glenn anastomosis, aiming to reduce the invasiveness of palliation in patients with univentricular heart defects, has been reported in large experimental animals. The advent of biodegradable stents and tissue-engineered vascular grafts will make this procedure a reality in human patients. However, the relationship between the superior vena cava (SVC) and the right pulmonary artery (RPA) is different in humans. To characterise vascular anatomy in children with univentricular hearts, regarding technical aspects and device design for this procedure. Retrospective analysis of 35 thoracic computed tomography angiograms at a mean age of 18.1±22.4 months. Two types of arrangement between the SVC and the RPA were identified: anatomy convenient for immediate wire passage and stent deployment between the two vessels (60%); and pattern of early RPA branching, requiring the perforation wire to traverse the intervascular space to avoid entrance into the upper RPA branch (40%). In patients with the convenient vascular arrangement, the vessels were nearly perpendicular, having immediate contact, with the posterior SVC aspect partially "wrapping" the adjacent RPA in most patients. In patients with early RPA branching, the mean shortest SVC-to-central RPA distance was 4.3±2.7mm. For the total population, the mean length of proximal SVC that allowed stent deployment without covering the brachiocephalic vein was 15.6±5.1mm. A trumpet-shaped covered stent in a craniocaudal orientation reaching from the SVC into the prebranching RPA seems most suitable for achieving bidirectional Glenn anastomosis percutaneously in humans. However, the short length of the proximal SVC and the presence of early RPA branching pose challenges for optimal design of the dedicated device. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. A Concentration-Dependent Insulin Immobilization Behavior of Alkyl-Modified Silica Vesicles: The Impact of Alkyl Chain Length.

    PubMed

    Zhang, Jun; Zhang, Long; Lei, Chang; Huang, Xiaodan; Yang, Yannan; Yu, Chengzhong

    2018-05-01

    The insulin immobilization behaviors of silica vesicles (SV) before and after modification with hydrophobic alkyl -C 8 and -C 18 groups have been studied and correlated to the grafted alkyl chain length. In order to minimize the influence from the other structural parameters, monolayered -C 8 or -C 18 groups are grafted onto SV with controlled density. The insulin immobilization capacity of SV is dependent on the initial insulin concentrations (IIC). At high IIC (2.6-3.0 mg/mL), the trend of insulin immobilization capacity of SV is SV-OH > SV-C 8 > SV-C 18 , which is determined mainly by the surface area of SV. At medium IIC (0.6-1.9 mg/mL), the trend changes to SV-C 8 ≥ SV-C 18 > SV-OH as both the surface area and alkyl chain length contribute to the insulin immobilization. At an extremely low IIC, the hydrophobic-hydrophobic interaction between the alkyl group and insulin molecules plays the most significant role. Consequently, SV-C 18 with longer alkyl groups and the highest hydrophobicity show the best insulin enrichment performance compared to SV-C 8 and SV-OH, as evidenced by an insulin detection limit of 0.001 ng/mL in phosphate buffered saline (PBS) and 0.05 ng/mL in artficial urine determined by mass spectrometry (MS).

  5. Intra- and Inter-rater Agreement of Superior Vena Cava Flow and Right Ventricular Outflow Measurements in Late Preterm and Term Neonates.

    PubMed

    Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike

    2018-02-24

    To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.

  6. Analysis of SVC’s Impact on Out-of-step Oscillation Based on Direct Method Considering Admittance Effect

    NASA Astrophysics Data System (ADS)

    He, Jing-bo; Ding, Jian; Feng, Li; Ren, Jian-wen; Tang, Wei; Yang, Cheng; Wang, Jing-jin; Song, Yun-ting

    2017-05-01

    The widely employment of power electronic equipment in modern power system, may affect grid structure and system operation because of their diverse dynamic characteristics. In this paper, the impact of the static var compensators (SVC) on out-of-step oscillation is investigated based on the equal area criterion by considering SVC’s admittance effect. Firstly, the variation pattern of bus voltage which is connected to SVC is concluded. Then the derivation of equation considering the admittance effect is given, which explains the ability of SVC to suppress out-of-step oscillation. SVC’s impact on migration of out-of-step oscillation centre (OSOC) is discussed based on the expression of OSOC’s electrical location. Moreover, the influence of SVC’s response speed and capacity on its effect are presented by qualitative analysis. Finally, simulations on a two-end equivalent test system are carried out to verify the correctness of the theoretical analysis. It is found that the capacity and a response speed of SVC have significant effect on the out-of-step oscillation, while SVC have no d istinct influence on location of OSOC.

  7. Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu

    Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less

  8. Comparison of tricuspid inflow and superior vena caval Doppler velocities in acute simulated hypovolemia: new non-invasive indices for evaluating right ventricular preload.

    PubMed

    Liu, Jie; Cao, Tie-Sheng; Yuan, Li-Jun; Duan, Yun-You; Yang, Yi-Lin

    2006-05-16

    Assessment of cardiac preload is important for clinical management of some emergencies related to hypovolemia. Effects of acute simulated hypovolemia on Doppler blood flow velocity indices of tricuspid valve (TV) and superior vena cava (SVC) were investigated in order to find sensitive Doppler indices for predicting right ventricular preload. Doppler flow patterns of SVC and TV in 12 healthy young men were examined by transthoracic echocardiography (TTE) during graded lower body negative pressure (LBNP) of up to -60 mm Hg which simulated acute hypovolemia. Peak velocities of all waves and their related ratios (SVC S/D and tricuspid E/A) were measured, calculated and statistically analyzed. Except for the velocity of tricuspid A wave, velocities of all waves and their related ratios declined during volume decentralization. Of all indices measured, the peak velocities of S wave and AR wave in SVC correlated most strongly with levels of LBNP (r = -0.744 and -0.771, p < 0.001). The S and AR velocities are of good values in assessing right ventricular preload. Monitoring SVC flow may provide a relatively noninvasive means to assess direct changes in right ventricular preload.

  9. Neutropenia is independently associated with sub-therapeutic serum concentration of vancomycin.

    PubMed

    Choi, Min Hyuk; Choe, Yeon Hwa; Lee, Sang-Guk; Jeong, Seok Hoon; Kim, Jeong-Ho

    2017-02-01

    We aimed to identify the impact of the presence of neutropenia on serum vancomycin concentration (SVC). A retrospective study was conducted from January 2005 to December 2015. The study population was comprised of adult patients who were performed serum concentration of vancomycin. Patients with renal failure or using non-conventional dosages of vancomycin were excluded. A total of 1307 adult patients were included in this study, of whom 163 (12.4%) were neutropenic. Patients with neutropenia presented significantly lower SVCs than non-neutropenic patients (P<0.0001). Multiple linear regressions showed significant association between neutropenia and trough SVC (beta coefficients, -2.351; P=0.004). Multiple logistic regression analysis also revealed a significant association between sub-therapeutic vancomycin concentrations (trough SVC values<10mg/l) and neutropenia (odds ratio, 1.75, P=0.029) CONCLUSIONS: The presence of neutropenia is significantly associated with low SVC, even after adjusting for other variables. Therefore, neutropenic patients had a higher risk of sub-therapeutic SVC compared with non-neutropenic patients. We recommended that vancomycin therapy should be monitored with TDM-guided optimization of dosage and intervals, especially in neutropenic patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sofue, Keitaro, E-mail: keitarosofue@yahoo.co.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp

    A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.

  11. CMMI (registered trademark) for Services (CMMI-SVC) Overview for Workshop

    DTIC Science & Technology

    2008-08-01

    is from “DoD throws light on how it buys services [GCN 2006].” GAO data is from GAO report GAO-07-20. 5 CMMI for Services (CMMI-SVC) Forrester...Service Addition PAs 3 5 1 22 % of CMMI-DEV PAs are reused; % of Corporate Investments are potentially r usable! CMMI-DEV CMMI-ACQ CMMI-SVC 77...Service Modifications: •  21 amplification in 7 PAs •  5 added references •  1 modified PA (REQM) •  1 specific goal •  2 specific practices

  12. Voltage stability index based optimal placement of static VAR compensator and sizing using Cuckoo search algorithm

    NASA Astrophysics Data System (ADS)

    Venkateswara Rao, B.; Kumar, G. V. Nagesh; Chowdary, D. Deepak; Bharathi, M. Aruna; Patra, Stutee

    2017-07-01

    This paper furnish the new Metaheuristic algorithm called Cuckoo Search Algorithm (CSA) for solving optimal power flow (OPF) problem with minimization of real power generation cost. The CSA is found to be the most efficient algorithm for solving single objective optimal power flow problems. The CSA performance is tested on IEEE 57 bus test system with real power generation cost minimization as objective function. Static VAR Compensator (SVC) is one of the best shunt connected device in the Flexible Alternating Current Transmission System (FACTS) family. It has capable of controlling the voltage magnitudes of buses by injecting the reactive power to system. In this paper SVC is integrated in CSA based Optimal Power Flow to optimize the real power generation cost. SVC is used to improve the voltage profile of the system. CSA gives better results as compared to genetic algorithm (GA) in both without and with SVC conditions.

  13. Evaluation of serial urine viral cultures for the diagnosis of cytomegalovirus infection in neonates and infants.

    PubMed

    Chisholm, Karen M; Aziz, Natali; McDowell, Michal; Guo, Frances P; Srinivas, Nivedita; Benitz, William E; Norton, Mary E; Gutierrez, Kathleen; Folkins, Ann K; Pinsky, Benjamin A

    2014-01-01

    Cytomegalovirus (CMV) is the most common cause of congenital infection worldwide. Urine viral culture is the standard for CMV diagnosis in neonates and infants. The objectives of this study were to compare the performance of serial paired rapid shell vial cultures (SVC) and routine viral cultures (RVC), and to determine the optimal number of cultures needed to detect positive cases. From 2001 to 2011, all paired CMV SVC and RVC performed on neonates and infants less than 100 days of age were recorded. Testing episodes were defined as sets of cultures performed within 7 days of one another. A total of 1264 neonates and infants underwent 1478 testing episodes; 68 (5.4%) had at least one episode with a positive CMV culture. In episodes where CMV was detected before day 21 of life, the first specimen was positive in 100% (16/16) of cases. When testing occurred after 21 days of life, the first specimen was positive in 82.7% (43/52) of cases, requiring three cultures to reach 100% detection. The SVC was more prone to assay failure than RVC. Overall, when RVC was compared to SVC, there was 86.0% positive agreement and 99.9% negative agreement. In conclusion, three serial urine samples are necessary for detection of CMV in specimens collected between day of life 22 and 99, while one sample may be sufficient on or before day of life 21. Though SVC was more sensitive than RVC, the risk of SVC failure supports the use of multimodality testing to optimize detection.

  14. The second virial coefficient of bounded Mie potentials

    NASA Astrophysics Data System (ADS)

    Heyes, D. M.; Pereira de Vasconcelos, T.

    2017-12-01

    The second virial coefficient (SVC) of bounded generalizations of the Mie m:n potential ϕ (r ) =λ [1 /(aq+rq ) m /q-1 /(aq+rq ) n /q ] , where λ, a, q, m, and n are constants (a ≥ 0), is explored. The particle separation distance is r. This potential could be used as an effective interaction between polymeric dispersed colloidal particles of various degrees of interpenetrability. The SVC is negative for all temperatures for a, greater than a critical value, ac, which coincides with the range of a, where the system is thermodynamically unstable. The Boyle temperature and the temperature at which the SVC is a maximum diverge to +∞ as a → ac from below. Various series expansion expressions for the SVC are derived following on from those derived for the Mie potential itself (i.e., a = 0) in the study of Heyes et al. [J. Chem. Phys. 145, 084505 (2016)]. Formulas based on an expansion of the exponential in the Mayer function definition of the SVC are formally convergent, but pose numerical problems for the useful range of a < 1. High temperature expansion (HTE) formulas extending those in the previous publication are derived, which in contrast converge rapidly for the full a range. The HTE formulas derived in this work could be useful in guiding the choice of nucleation and growth experimental conditions for dispersed soft polymeric particles. Inter alia, the SVC of the inverse power special case of the Bounded Mie potential, i .e ., ϕ (r ) =1 /(aq+rq ) m /q, are also derived.

  15. Human aortic allograft: an excellent conduit choice for superior vena cava reconstruction

    PubMed Central

    2014-01-01

    Superior vena cava (SVC) reconstruction is occasionally required in the treatment of benign and malignant conditions. We report a patient with symptomatic SVC obstruction secondary to mediastinal fibrosis successfully reconstructed with an aortic allograft. PMID:24428914

  16. Superior Vena Cava Stent Migration into the Pulmonary Artery Causing Fatal Pulmonary Infarction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, Girija, E-mail: gijanandm@hotmail.com; Lewanski, Conrad R.; Cowman, Steven A.

    2011-02-15

    Migration of superior vena cava (SVC) stents is a well-recognised complication of their deployment, and numerous strategies exist for their retrieval. To our knowledge, only three cases of migration of an SVC stent to the pulmonary vasculature have previously been reported. None of these patients developed complications that resulted in death. We report a case of SVC stent migration to the pulmonary vasculature with delayed pulmonary artery thrombosis and death from pulmonary infarction. We conclude that early retrieval of migrated stents should be performed to decrease the risk of serious complications.

  17. Application of Static Var Compensator (SVC) With PI Controller for Grid Integration of Wind Farm Using Harmony Search

    NASA Astrophysics Data System (ADS)

    Keshta, H. E.; Ali, A. A.; Saied, E. M.; Bendary, F. M.

    2016-10-01

    Large-scale integration of wind turbine generators (WTGs) may have significant impacts on power system operation with respect to system frequency and bus voltages. This paper studies the effect of Static Var Compensator (SVC) connected to wind energy conversion system (WECS) on voltage profile and the power generated from the induction generator (IG) in wind farm. Also paper presents, a dynamic reactive power compensation using Static Var Compensator (SVC) at the a point of interconnection of wind farm while static compensation (Fixed Capacitor Bank) is unable to prevent voltage collapse. Moreover, this paper shows that using advanced optimization techniques based on artificial intelligence (AI) such as Harmony Search Algorithm (HS) and Self-Adaptive Global Harmony Search Algorithm (SGHS) instead of a Conventional Control Method to tune the parameters of PI controller for SVC and pitch angle. Also paper illustrates that the performance of the system with controllers based on AI is improved under different operating conditions. MATLAB/Simulink based simulation is utilized to demonstrate the application of SVC in wind farm integration. It is also carried out to investigate the enhancement in performance of the WECS achieved with a PI Controller tuned by Harmony Search Algorithm as compared to a Conventional Control Method.

  18. Estimating the potential refolding yield of recombinant proteins expressed as inclusion bodies.

    PubMed

    Ho, Jason G S; Middelberg, Anton P J

    2004-09-05

    Recombinant protein production in bacteria is efficient except that insoluble inclusion bodies form when some gene sequences are expressed. Such proteins must undergo renaturation, which is an inefficient process due to protein aggregation on dilution from concentrated denaturant. In this study, the protein-protein interactions of eight distinct inclusion-body proteins are quantified, in different solution conditions, by measurement of protein second virial coefficients (SVCs). Protein solubility is shown to decrease as the SVC is reduced (i.e., as protein interactions become more attractive). Plots of SVC versus denaturant concentration demonstrate two clear groupings of proteins: a more aggregative group and a group having higher SVC and better solubility. A correlation of the measured SVC with protein molecular weight and hydropathicity, that is able to predict which group each of the eight proteins falls into, is presented. The inclusion of additives known to inhibit aggregation during renaturation improves solubility and increases the SVC of both protein groups. Furthermore, an estimate of maximum refolding yield (or solubility) using high-performance liquid chromatography was obtained for each protein tested, under different environmental conditions, enabling a relationship between "yield" and SVC to be demonstrated. Combined, the results enable an approximate estimation of the maximum refolding yield that is attainable for each of the eight proteins examined, under a selected chemical environment. Although the correlations must be tested with a far larger set of protein sequences, this work represents a significant move beyond empirical approaches for optimizing renaturation conditions. The approach moves toward the ideal of predicting maximum refolding yield using simple bioinformatic metrics that can be estimated from the gene sequence. Such a capability could potentially "screen," in silico, those sequences suitable for expression in bacteria from those that must be expressed in more complex hosts.

  19. Prospective Evaluation of Electromyography-Guided Phrenic Nerve Monitoring During Superior Vena Cava Isolation to Anticipate Phrenic Nerve Injury.

    PubMed

    Miyazaki, Shinsuke; Ichihara, Noboru; Nakamura, Hiroaki; Taniguchi, Hiroshi; Hachiya, Hitoshi; Araki, Makoto; Takagi, Takamitsu; Iwasawa, Jin; Kuroi, Akio; Hirao, Kenzo; Iesaka, Yoshito

    2016-04-01

    Right phrenic nerve injury (PNI) is a major concern during superior vena cava (SVC) isolation due to the anatomical close proximity. The functional and histological severity of PNI parallels the degree of the reduction in the compound motor action potential (CMAP) amplitude. This study aimed to evaluate the feasibility of monitoring CMAPs during SVC isolation to anticipate PNI during atrial fibrillation (AF) ablation. Thirty-nine paroxysmal AF patients were prospectively enrolled. Radiofrequency energy was delivered point-by-point for 30 seconds with 20 W until eliminating all SVC potentials after the pulmonary vein isolation. Right diaphragmatic CMAPs were obtained from modified surface electrodes by pacing from the right subclavian vein. Radiofrequency applications were applied without fluoroscopy under CMAP monitoring at sites with phrenic nerve capture by high output pacing. Electrical SVC isolation was successfully achieved with a mean of 9.4 ± 3.3 applications in all patients. In 3 (7.5%) patients, the SVC was isolated without radiofrequency delivery at phrenic nerve capture sites. Among a total of 346 applications in the remaining 36 patients, 71 (20.5%) were delivered while monitoring CMAPs. In 1 (1.4%) application, the RF application was interrupted due to a decrease in the CMAP amplitude. However, no PNI was detected on fluoroscopy, and the decreased amplitude recovered spontaneously. The remaining 70 (98.6%) applications exhibited no significant changes in the CMAP amplitude throughout the applications (from 1.01 ± 0.47 to 0.98 ± 0.45 mV, P = 0.383). Stable right diaphragmatic CMAPs could be obtained, and monitoring CMAPs might be useful for anticipating right PNI during SVC isolation. © 2016 Wiley Periodicals, Inc.

  20. Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Eric; Fenaughty, Karen; Parker, Danny

    Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies among regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

  1. Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Eric; Fenaughty, Karen; Parker, Danny

    Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies amongst regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

  2. Plasmonic enhancement of a silicon-vacancy center in a nanodiamond crystal

    NASA Astrophysics Data System (ADS)

    Meng, Xiang; Liu, Shang; Dadap, Jerry I.; Osgood, Richard M.

    2017-06-01

    This work reports a rigorous and comprehensive three-dimensional electromagnetic computation to investigate and design photoluminescence enhancement from a single silicon-vacancy center (SVC) in a nanodiamond crystal embedded in various metallic nanoantennae, each having a different geometry. The study demonstrates how each antenna design enhances the photoluminescence of SVCs in diamond. In particular, our report discusses how the 2D or 3D curvature of the nanoantenna and the control of the local environment of the SVC can lead to significant field enhancement of its optical field. Our calculated optimal photoluminescence for each design enhances the emission intensity by 15 -300 × that of a single SVC without antenna. The enhancement mechanisms are investigated using four representative structures that can be fabricated under feasible and realistic growth conditions, i.e., spherical-, nanorod-, nanodisk-dimer, and bow-tie nanoantennae. These results demonstrate a method for rationally designing arbitrary metallic nanoantenna/emitter assemblies to achieve optimal SVC photoluminescence.

  3. Association of Microcirculation, Macrocirculation, and Severity of Illness in Septic Shock: A Prospective Observational Study to Identify Microcirculatory Targets Potentially Suitable for Guidance of Hemodynamic Therapy.

    PubMed

    Sturm, Timo; Leiblein, Julia; Schneider-Lindner, Verena; Kirschning, Thomas; Thiel, Manfred

    2018-04-01

    Clinically unapparent microcirculatory impairment is common and has a negative impact on septic shock, but specific therapy is not established so far. This prospective observational study aimed at identifying candidate parameters for microcirculatory-guided hemodynamic therapy. ClinicalTrials.gov : NCT01530932. Microcirculatory flow and postcapillary venous oxygen saturation were detected during vaso-occlusive testing (VOT) on days 1 (T0), 2 (T24), and 4 (T72) in 20 patients with septic shock at a surgical intensive care unit using a laser Doppler spectrophotometry system (O2C). Reperfusional maximal venous capillary oxygen saturation (SvcO 2 max) showed negative correlations with Simplified Acute Physiology Score II (SAPSII)/Sequential Organ Failure Assessment (SOFA) score, norepinephrine dosage, and lactate concentration and showed positive correlations with cardiac index (CI). At T24 and T72, SvcO 2 max was also inversely linked to fluid balance. With respect to any predictive value, SvcO 2 max and CI determined on day 1 (T0) were negatively correlated with SAPS II/SOFA on day 4 (T72). Moreover, SvcO 2 max measured on day 1 or day 2 was negatively correlated with cumulated fluid balance on day 4 ( r= -.472, P < .05 and r = -.829, P < .001). By contrast, CI neither on day 1 nor on day 2 was correlated with cumulated fluid balance on day 4 ( r = -.343, P = .17 and r = -.365, P = .15). In patients with septic shock, microcirculatory reserve as assessed by SvcO 2 max following VOT was impaired and negatively correlated with severity of illness and fluid balance. In contrast to CI, SvcO 2 max determined on day 1 or day 2 was significantly negatively correlated with cumulative fluid balance on day 4. Therefore, early microcirculatory measurement of SvcO 2 max might be superior to CI in guidance of sepsis therapy to avoid fluid overload. This has to be addressed in future clinical studies.

  4. Surgical repair of an unusual type of supra-cardiac total anomalous pulmonary venous connection to the superior vena cava.

    PubMed

    Perri, Gianluigi; Filippelli, Sergio; Kirk, Richard; Hasan, Asif; Griselli, Massimo

    2012-05-01

    Anomalies of the pulmonary venous drainage vary widely in their anatomic spectrum and clinical presentation. We describe an unusual case of supra-cardiac total anomalous pulmonary venous connection (TAPVC), where the pulmonary veins drained directly in the posterior aspect of proximal right superior vena cava (SVC) through separate ostia. The veins were re-routed with a patch to the left atrium via the secundum atrial septal defect (ASD). The continuity between distal SVC and right atrium was re-established by re-implanting the SVC to the right atrial appendage (Warden Procedure). © 2012 Wiley Periodicals, Inc.

  5. Association Between Decline in Slow Vital Capacity and Respiratory Insufficiency, Use of Assisted Ventilation, Tracheostomy, or Death in Patients With Amyotrophic Lateral Sclerosis

    PubMed Central

    Meng, Lisa; Kulke, Sarah F.; Rudnicki, Stacy A.; Wolff, Andrew A.; Bozik, Michael E.; Malik, Fady I.; Shefner, Jeremy M.

    2017-01-01

    Importance The prognostic value of slow vital capacity (SVC) in relation to respiratory function decline and disease progression in patients with amyotrophic lateral sclerosis (ALS) is not well understood. Objective To investigate the rate of decline in percentage predicted SVC and its association with respiratory-related clinical events and mortality in patients with ALS. Design, Setting, and Participants This retrospective study included 893 placebo-treated patients from 2 large clinical trials (EMPOWER and BENEFIT-ALS, conducted from March 28, 2011, to November 1, 2012, and from October 23, 2012, to March 21, 2014, respectively) and an ALS trial database (PRO-ACT, containing studies completed between 1990 and 2010) to investigate the rate of decline in SVC. Data from the EMPOWER trial (which enrolled adults with possible, probable, or definite ALS; symptom onset within 24 months before screening; and upright SVC at least 65% of predicted value for age, height, and sex) were used to assess the relationship of SVC to respiratory-related clinical events; 456 patients randomized to placebo were used in this analysis. The 2 clinical trials included patients from North America, Australia, and Europe. Main Outcomes and Measures Clinical events included the earlier of time to death or time to decline in the Amyotrophic Lateral Sclerosis Functional Rating Scale–Revised (ALSFRS-R) respiratory subdomain, time to onset of respiratory insufficiency, time to tracheostomy, and all-cause mortality. Results Among 893 placebo-treated patients with ALS, the mean (SD) patient age was 56.7 (11.2) years, and the mean (SD) SVC was 90.5% (17.1%) at baseline; 65.5% (585 of 893) were male, and 20.5% (183 of 893) had bulbar-onset ALS. In EMPOWER, average decline of SVC from baseline through 1.5-year follow-up was −2.7 percentage points per month. Steeper declines were found in patients older than 65 years (−3.6 percentage points per month [P = .005 vs <50 years and P = .007 vs 50-65 years) and in patients with an ALSFRS-R total score of 39 or less at baseline (−3.1 percentage points per month [P < .001 vs >39]). When the rate of decline of SVC was slower by 1.5 percentage points per month in the first 6 months, risk reductions for events after 6 months were 19% for decline in the ALSFRS-R respiratory subdomain or death after 6 months, 22% for first onset of respiratory insufficiency or death after 6 months, 23% for first occurrence of tracheostomy or death after 6 months, and 23% for death at any time after 6 months (P < .001 for all). Conclusions and Relevance The rate of decline in SVC is associated with meaningful clinical events in ALS, including respiratory failure, tracheostomy, or death, suggesting that it is an important indicator of clinical progression. PMID:29181534

  6. Observations of Subvisible Cirrus Clouds and Gravity Waves at the Tropical Tropopause

    NASA Technical Reports Server (NTRS)

    Pfister, Leonhard; Browell, E. V.; Hipskind, R. Stephen (Technical Monitor)

    1998-01-01

    Thin, subvisible cirrus (SVC) clouds at the tropical tropopause have been observed by a number of methods in a variety of observational programs, including in situ sampling and aircraft and space-based lidar. Modeling studies suggest that these clouds play an important role in dehydrating tropospheric air as it enters the stratosphere. This is because particles large enough to have significant fall speeds can form under the conditions of slow cooling that are implied by the large horizontal extent of the SVC sheets. The IR radiation that these clouds absorb, and the upward vertical motion this implies, also makes them candidates for a tropical troposphere-to-stratosphere mass transfer mechanism. They may also play a role in the earth's radiation budget. These sheets were observed on five flights during the Tropical Ozone Transport Experiment (TOTE) by the NASA Langley DIAL lidar aboard NASA's DC-8 research aircraft operating during December 1995 and February 1996 south of Hawaii. The relationship of the SVC's observed during TOTE to convection was not a simple one. One class of SVC's are within 1000 km of the persistent strong convection near 15S (the SPCZ). Trajectory analyses indicated that the SVC air masses have in fact passed through the SPCZ within a few days of observation. These clouds are very close to the tropopause, with maximum potential temperatures not much higher than 370K, consistent with in situ water and total water measurements near the tropopause made during the Stratosphere Troposphere Exchange Project in January 1987 at Darwin, Australia. A second class of SVC's are not immediately downstream of convection. These clouds tend to be higher, reaching potential temperatures of 390K or more. Trajectory analyses indicate that the air in these SVC's originates either in the equatorial western Pacific or along the subtropical jet. In any case, the warm temperatures the SVC air masses encounter just prior to the observation time along the back trajectory imply that the clouds cannot be residual particles from cirrus blowoff, but must form locally as the air move upward and equatorward south of Hawaii. Since all the parcels have encountered colder temperatures than those at the time of observation early in their history, subsynoptic scale temperatures colder than the analysis temperatures appear to be required to explain the formation of ice particles. In fact, the sloping shapes of the SVC's do suggest that they are gravity or inertia-gravity waves. In situ meteorological measurements made by the ER-2 within a day of the DC-8 remote lidar observations show a gravity wave structure near the equator with an estimated period of about 30 hours. This is sufficiently long to allow large particles to form and fall out (thus allowing dehydration). Other ER-2 flights south of Hawaii at other times of year show gravity and inertia-gravity waves with a poleward wavenumber component and significant (5 degrees peak to peak) temperature perturbation.

  7. 9 CFR 53.10 - Claims not allowed.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... destruction of fish due to infectious salmon anemia (ISA) unless the claimants have agreed in writing to... water and are free of wild carp and any other SVC-susceptible species; and (iii) Prevented the migration of wild carp and any other wild SVC-susceptible species into their farming establishment. (Approved...

  8. 9 CFR 53.10 - Claims not allowed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... destruction of fish due to infectious salmon anemia (ISA) unless the claimants have agreed in writing to... water and are free of wild carp and any other SVC-susceptible species; and (iii) Prevented the migration of wild carp and any other wild SVC-susceptible species into their farming establishment. (Approved...

  9. 9 CFR 53.10 - Claims not allowed.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... destruction of fish due to infectious salmon anemia (ISA) unless the claimants have agreed in writing to... water and are free of wild carp and any other SVC-susceptible species; and (iii) Prevented the migration of wild carp and any other wild SVC-susceptible species into their farming establishment. (Approved...

  10. 9 CFR 53.10 - Claims not allowed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... destruction of fish due to infectious salmon anemia (ISA) unless the claimants have agreed in writing to... water and are free of wild carp and any other SVC-susceptible species; and (iii) Prevented the migration of wild carp and any other wild SVC-susceptible species into their farming establishment. (Approved...

  11. 9 CFR 53.10 - Claims not allowed.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... destruction of fish due to infectious salmon anemia (ISA) unless the claimants have agreed in writing to... water and are free of wild carp and any other SVC-susceptible species; and (iii) Prevented the migration of wild carp and any other wild SVC-susceptible species into their farming establishment. (Approved...

  12. Low-complexity transcoding algorithm from H.264/AVC to SVC using data mining

    NASA Astrophysics Data System (ADS)

    Garrido-Cantos, Rosario; De Cock, Jan; Martínez, Jose Luis; Van Leuven, Sebastian; Cuenca, Pedro; Garrido, Antonio

    2013-12-01

    Nowadays, networks and terminals with diverse characteristics of bandwidth and capabilities coexist. To ensure a good quality of experience, this diverse environment demands adaptability of the video stream. In general, video contents are compressed to save storage capacity and to reduce the bandwidth required for its transmission. Therefore, if these compressed video streams were compressed using scalable video coding schemes, they would be able to adapt to those heterogeneous networks and a wide range of terminals. Since the majority of the multimedia contents are compressed using H.264/AVC, they cannot benefit from that scalability. This paper proposes a low-complexity algorithm to convert an H.264/AVC bitstream without scalability to scalable bitstreams with temporal scalability in baseline and main profiles by accelerating the mode decision task of the scalable video coding encoding stage using machine learning tools. The results show that when our technique is applied, the complexity is reduced by 87% while maintaining coding efficiency.

  13. 9 CFR 93.903 - Import permits for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., fertilized eggs, and gametes. 93.903 Section 93.903 Animals and Animal Products ANIMAL AND PLANT HEALTH... General Provisions for Svc-Regulated Fish Species § 93.903 Import permits for live fish, fertilized eggs, and gametes. (a) Live fish, fertilized eggs, or gametes of SVC-susceptible species imported into the...

  14. 9 CFR 93.903 - Import permits for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., fertilized eggs, and gametes. 93.903 Section 93.903 Animals and Animal Products ANIMAL AND PLANT HEALTH... General Provisions for Svc-Regulated Fish Species § 93.903 Import permits for live fish, fertilized eggs, and gametes. (a) Live fish, fertilized eggs, or gametes of SVC-susceptible species imported into the...

  15. Application of support vector machines for copper potential mapping in Kerman region, Iran

    NASA Astrophysics Data System (ADS)

    Shabankareh, Mahdi; Hezarkhani, Ardeshir

    2017-04-01

    The first step in systematic exploration studies is mineral potential mapping, which involves classification of the study area to favorable and unfavorable parts. Support vector machines (SVM) are designed for supervised classification based on statistical learning theory. This method named support vector classification (SVC). This paper describes SVC model, which combine exploration data in the regional-scale for copper potential mapping in Kerman copper bearing belt in south of Iran. Data layers or evidential maps were in six datasets namely lithology, tectonic, airborne geophysics, ferric alteration, hydroxide alteration and geochemistry. The SVC modeling result selected 2220 pixels as favorable zones, approximately 25 percent of the study area. Besides, 66 out of 86 copper indices, approximately 78.6% of all, were located in favorable zones. Other main goal of this study was to determine how each input affects favorable output. For this purpose, the histogram of each normalized input data to its favorable output was drawn. The histograms of each input dataset for favorable output showed that each information layer had a certain pattern. These patterns of SVC results could be considered as regional copper exploration characteristics.

  16. Comparison of superior vena caval and inferior vena caval access using a radioisotope technique during normal perfusion and cardiopulmonary resuscitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dalsey, W.C.; Barsan, W.G.; Joyce, S.M.

    1984-10-01

    Recent studies of thoracic pressure changes during external cardiopulmonary resuscitation (CPR) suggest that there may be a significant difference in the rate of delivery of intravenous drugs when they are administered through the extrathoracic inferior vena cava (IVC) rather than the intrathoracic superior vena cava (SVC). Comparison of delivery of a radionuclide given using superior and inferior vena caval access sites was made during normal blood flow and during CPR. Mean times from injection to peak emission count in each ventricle were determined. There were no significant differences between mean peak times for SVC or IVC routes during normal flowmore » or CPR. When peak times were corrected for variations in cardiac output, there were no significant differences between IVC and SVC peak times during normal flow. During CPR, however, mean left ventricular peak time, when corrected for cardiac output, was significantly shorter (P less than .05) when the SVC route was used. The mean time for the counts to reach half the ventricular peak was statistically shorter (P less than .05) in both ventricles with the SVC route during the low flow of CPR. This suggests that during CPR, increased drug dispersion may occur when drugs are infused by the IVC route and thus may modify the anticipated effect of the drug bolus. These results suggest that during CPR, both the cardiac output and the choice of venous access are important variables for drug delivery.« less

  17. The assisted bidirectional Glenn: a novel surgical approach for first-stage single-ventricle heart palliation.

    PubMed

    Esmaily-Moghadam, Mahdi; Hsia, Tain-Yen; Marsden, Alison L

    2015-03-01

    Outcomes after a modified Blalock-Taussig shunt (mBTS) in neonates with single-ventricle physiology remain unsatisfactory. However, initial palliation with a superior cavopulmonary connection, such as a bidirectional Glenn (BDG), is discouraged, owing to potential for inadequate pulmonary blood flow (PBF). We tested the feasibility of a novel surgical approach, adopting the engineering concept of an ejector pump, whereby the flow in the BDG is "assisted" by injection of a high-energy flow stream from the systemic circulation. Realistic 3-dimensional models of the neonatal mBTS and BDG circulations were created. The "assisted" bidirectional Glenn (ABG) consisted of a shunt between the right innominate artery and the superior vena cava (SVC), with a 1.5-mm clip near the SVC anastomosis to create a Venturi effect. The 3 models were coupled to a validated hydraulic circulation model, and 2 pulmonary vascular resistance (PVR) values (7 and 2.3 Wood units) were simulated. The ABG provided the highest systemic oxygen saturation and oxygen delivery at both PVR levels. In addition to achieving higher PBF than the BDG, the ABG produced a lower single-ventricular workload than mBTS. SVC pressure was highest in the ABG model (ABG: 15; Glenn: 11; mBTS: 3 mm Hg; PVR = 7 Wood units), but at low PVR, the SVC pressure was significantly lower (ABG: 8; Glenn: 6; mBTS: <3 mm Hg). Adopting the principle of an ejector pump, with additional flow directed into the SVC in a BDG, the ABG appears to increase PBF with a modest increase in SVC and pulmonary arterial pressure. Although multiscale modeling results demonstrate the conceptual feasibility of the ABG circulation, further technical refinement and investigations are necessary, especially in an appropriate animal model. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Ultrasound confirmation of central venous catheter position via a right supraclavicular fossa view using a microconvex probe: an observational pilot study.

    PubMed

    Kim, Se-Chan; Heinze, Ingo; Schmiedel, Alexandra; Baumgarten, Georg; Knuefermann, Pascal; Hoeft, Andreas; Weber, Stefan

    2015-01-01

    Visualisation of a central venous catheter (CVC) with ultrasound is restricted to the internal jugular vein (IJV). CVC tip position is confirmed by chest radiography, intracardiac ECG or transoesophageal/transthoracic echocardiography (TEE/TTE). We explored the feasibility, safety and accuracy of a right supraclavicular view for visualisation of the lower superior vena cava (SVC) and the right pulmonary artery (RPA) as an ultrasound landmark for real-time ultrasound-guided CVC tip positioning via the right IJV. Ultrasound was then compared with chest radiography. An observational pilot study. Bonn, University Hospital, Germany. From July to October 2012. Fifty-one patients scheduled for elective surgery. Reasons for exclusion were emergency procedure, thrombosis or small IJV lumen and mechanical obstacle to guidewire advancement. In 48 patients, CVC insertion via the right IJV and progress of the guidewire into the lower SVC were continuously guided by an ultrasound transducer in the right supraclavicular fossa. CVC tip position in lower SVC and tip-to-carina distance were assessed with chest radiography as a reference method and additionally with TEE in cardiothoracic patients. Insertion depth was compared with intracardiac ECG and body-height formula. The guidewire tip was seen in the SVC of all patients. In four patients, the tip was not visible in proximity of the RPA. Chest radiography and TEE confirmed CVC tip position in the lower SVC (zone A). Bland-Altman analysis revealed an average of difference of 1.6 cm for ultrasound versus ECG (95% limit of agreement -2 to 5 cm) and an average of difference of 1 cm for ultrasound versus body-height formula (95% limit of agreement -2 to 4 cm). Ultrasound via a right supraclavicular view is a feasible, well tolerated and accurate approach and should be further explored. Chest radiography confirmed CVC position in the lower SVC.

  19. A prospective comparison of phakic collamer lenses and wavefront-optimized laser-assisted in situ keratomileusis for correction of myopia

    PubMed Central

    Parkhurst, Gregory D

    2016-01-01

    Purpose The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS) in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK). Patients and methods This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL) and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles. Results Preoperative mean spherical equivalent was −6.10 D in the ICL group and −6.04 D in the LASIK group (P=0.863). Three months postoperatively, super vision acuity (SVa), super vision acuity with (low-luminance) goggles (SVaG), super vision contrast (SVc), and super vision contrast with (low luminance) goggles (SVcG) significantly improved in the ICL and LASIK groups (P<0.001). Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =−0.134, LASIK =−0.085; P=0.032). Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024). Mean improvement in SVa at 3 months was comparable in both groups (P=0.154). Conclusion Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction. PMID:27418804

  20. A prospective comparison of phakic collamer lenses and wavefront-optimized laser-assisted in situ keratomileusis for correction of myopia.

    PubMed

    Parkhurst, Gregory D

    2016-01-01

    The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS) in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK). This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL) and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles. Preoperative mean spherical equivalent was -6.10 D in the ICL group and -6.04 D in the LASIK group (P=0.863). Three months postoperatively, super vision acuity (SVa), super vision acuity with (low-luminance) goggles (SVaG), super vision contrast (SVc), and super vision contrast with (low luminance) goggles (SVcG) significantly improved in the ICL and LASIK groups (P<0.001). Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =-0.134, LASIK =-0.085; P=0.032). Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024). Mean improvement in SVa at 3 months was comparable in both groups (P=0.154). Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction.

  1. Voter Participation in a Community College Referendum.

    ERIC Educational Resources Information Center

    Garner, W. Harold; Shapton, Karen

    Between 1983 and 1984, tax referenda for Sauk Valley College (SVC) were on the ballot three times. Research conducted before and after the tax referendum failed to pass in November 1983 provided the basis for strategy enhancement that brought SVC closer to its goal in March 1984 and finally to the achievement of the goal in November. In October…

  2. The genetic tale of a recovering lion population (Panthera leo) in the Savé Valley region (Zimbabwe): A better understanding of the history and managing the future

    PubMed Central

    Groom, Rosemary J.; Khuzwayo, Joy; Jansen van Vuuren, Bettine

    2018-01-01

    The rapid decline of the African lion (Panthera leo) has raised conservation concerns. In the Savé Valley Conservancy (SVC), in the Lowveld of Zimbabwe, lions were presumably reduced to approximately 5 to 10 individuals. After ten lions were reintroduced in 2005, the population has recovered to over 200 lions in 2016. Although the increase of lions in the SVC seems promising, a question remains whether the population is genetically viable, considering their small founding population. In this study, we document the genetic diversity in the SVC lion population using both mitochondrial and nuclear genetic markers, and compare our results to literature from other lion populations across Africa. We also tested whether genetic diversity is spatially structured between lion populations residing on several reserves in the Lowveld of Zimbabwe. A total of 42 lions were genotyped successfully for 11 microsatellite loci. We confirmed that the loss of allelic richness (probably resulting from genetic drift and small number of founders) has resulted in low genetic diversity and inbreeding. The SVC lion population was also found to be genetically differentiated from surrounding population, as a result of genetic drift and restricted natural dispersal due to anthropogenic barriers. From a conservation perspective, it is important to avoid further loss of genetic variability in the SVC lion population and maintain evolutionary potential required for future survival. Genetic restoration through the introduction of unrelated individuals is recommended, as this will increase genetic heterozygosity and improve survival and reproductive fitness in populations. PMID:29415031

  3. The genetic tale of a recovering lion population (Panthera leo) in the Savé Valley region (Zimbabwe): A better understanding of the history and managing the future.

    PubMed

    Tensen, Laura; Groom, Rosemary J; Khuzwayo, Joy; Jansen van Vuuren, Bettine

    2018-01-01

    The rapid decline of the African lion (Panthera leo) has raised conservation concerns. In the Savé Valley Conservancy (SVC), in the Lowveld of Zimbabwe, lions were presumably reduced to approximately 5 to 10 individuals. After ten lions were reintroduced in 2005, the population has recovered to over 200 lions in 2016. Although the increase of lions in the SVC seems promising, a question remains whether the population is genetically viable, considering their small founding population. In this study, we document the genetic diversity in the SVC lion population using both mitochondrial and nuclear genetic markers, and compare our results to literature from other lion populations across Africa. We also tested whether genetic diversity is spatially structured between lion populations residing on several reserves in the Lowveld of Zimbabwe. A total of 42 lions were genotyped successfully for 11 microsatellite loci. We confirmed that the loss of allelic richness (probably resulting from genetic drift and small number of founders) has resulted in low genetic diversity and inbreeding. The SVC lion population was also found to be genetically differentiated from surrounding population, as a result of genetic drift and restricted natural dispersal due to anthropogenic barriers. From a conservation perspective, it is important to avoid further loss of genetic variability in the SVC lion population and maintain evolutionary potential required for future survival. Genetic restoration through the introduction of unrelated individuals is recommended, as this will increase genetic heterozygosity and improve survival and reproductive fitness in populations.

  4. Outcomes of video-assisted thoracoscopic surgery for transvenous lead extraction.

    PubMed

    Dai, Mingyan; Joyce, David L; Blackmon, Shanda; Friedman, M P H Paul A; Espinosa, Raul; Osborn, Michael J; Huang, Congxin; Cha, Yong-Mei

    2018-06-02

    To evaluate the outcomes of video-assisted thoracoscopic surgery (VATS) during transvenous lead extractions (TLEs). Ninety-one high-risk patients who underwent TLE in the operating room from January 1, 2015, through March 31, 2017, were included in the study. Of these, 9 patients underwent VATS during TLE. Their clinical characteristics, indications for lead extraction, and complications associated with TLE in the 9 patients who had VATS were compared with those for the 82 patients who did not have VATS. The mean (SD) age of the study patients was 61 (17) years (64.8% were male). The lead dwell time, number of leads extracted, and clinical comorbidities were similar between the two groups. Superior vena cava (SVC) tear occurred in 2 of the 9 patients in VATS group and in 1 of the 82 in the non-VATS group (22.2% vs 1.2%, P = .03). Of the 2 patients in the VATS group who had SVC tears, in 1 the tear was visualized immediately and there was no hemodynamic compromise. In the other patient, the SVC tear was within the pericardium; the blood pressure recovered quickly after sternotomy and repair. Both patients had complete lead extraction and survived hospitalization. The patient in the non-VATS group who had an SVC tear had a successful repair but died of postoperative complications. Utilization of VATS to facilitate TLE is beneficial for early recognition of SVC tear and timely surgical repair in select high-risk patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Gateway to Healthcare Careers for Vulnerable Students: A New Approach to the Teaching of Anatomy and Physiology

    ERIC Educational Resources Information Center

    DeCiccio, Albert; Kenny, Tammy; Lippacher, Linda; Flanary, Barry

    2011-01-01

    At Southern Vermont College (SVC) and at the nation's other colleges and universities, Anatomy and Physiology I (A&PI) is the gateway course into healthcare careers. Disturbingly, at SVC and elsewhere, many first-year students interested in healthcare careers do not succeed in this course. They withdraw from the course or the institution, or…

  6. The Student Voice Collaborative: An Effort to Systematize Student Participation in School and District Improvement

    ERIC Educational Resources Information Center

    Sussman, Ari

    2015-01-01

    This chapter recounts the first 3 years of the Student Voice Collaborative (SVC) in New York City, a district supported student leadership initiative that engages high school aged youth in school reform work at school and district levels. Based on his experiences developing and running the SVC, the author identifies nine design and implementation…

  7. Profiles of digestive enzymes of two competing planktivores, silver carp and gizzard shad, differ

    USGS Publications Warehouse

    Amberg, Jon J.; Jensen, Nathan R.; Erickson, Richard A.; Sauey, Blake W.; Jackson, Craig

    2018-01-01

    Typically, studies in digestive physiology in fish focus on a few enzymes and provide insight into the specific processes of the enzyme in a targeted species. Comparative studies assessing a wide number of digestive enzymes on fishes that compete for food resources are lacking, especially in the context of an introduced species. It is generally thought that the invasive silver carp (SVC; Hypophthalmichthys molitrix) directly compete for food resources with the native gizzard shad (GZS; Dorosoma cepedianum) in waters where they coexist. We compared 19 digestive enzymes between SVC and GZS throughout a year and in two rivers in the Midwestern United States: Illinois River and Wabash River. All digestive enzymes analyzed were detected in both SVC and GZS in both rivers. However, the profiles of the digestive enzymes varied by species. Alkaline phosphatase, valine arylamidase, acid phosphatase, naphthol-AS-BI-phosphohydrolase and N-acetyl-β-glucosaminidase were all much higher in SVC than in GZS. Differences between digestive enzyme profiles were also observed between rivers and months. This study demonstrates the utility of using an ecological approach to compare physiological features in fishes.

  8. NMR Study of the New Magnetic Superconductor CaK(Fe 0:951Ni0:049) 4As 4: Microscopic Coexistence of Hedgehog Spin-vortex Crystal and Superconductivity

    DOE PAGES

    Ding, Q. P.; Meier, W. R.; Bohmer, A. E.; ...

    2017-12-29

    Coexistence of a new-type antiferromagnetic (AFM) state, the so-called hedgehog spin-vortex crystal (SVC), and superconductivity (SC) is evidenced by 75As nuclear magnetic resonance study on single-crystalline CaK(Fe 0:951Ni0:049) 4As 4. The hedgehog SVC order is clearly demonstrated by the direct observation of the internal magnetic induction along the c axis at the As1 site (close to K) and a zero net internal magnetic induction at the As2 site (close to Ca) below an AFM ordering temperature T N ~ 52 K. The nuclear spin-lattice relaxation rate 1/T 1 shows a distinct decrease below T c ~ 10 K, providing alsomore » unambiguous evidence for the microscopic coexistence. Furthermore, based on the analysis of the 1/T 1 data, the hedgehog SVC-type spin correlations are found to be enhanced below T ~ 150 K in the paramagnetic state. Furthermore, these results indicate the hedgehog SVC-type spin correlations play an important role for the appearance of SC in the new magnetic superconductor.« less

  9. Patency of cavopulmonary connection studied by single phase electron beam computed tomography.

    PubMed

    Choi, Byoung Wook; Park, Young Hwan; Lee, Jong Kyun; Kim, Dong Joon; Kim, Min Jung; Choe, Kyu Ok

    2003-10-01

    The shunt patency and anatomic alteration of central PA after cavopulmonary connection was assessed by one phase electron-beam computed tomography (EBCT) METHODS: Thirteen patients that received a bi-directional cavo-pulmonary shunt (BCPS, n = 7) or total cavo-pulmonary connection (TCPC, n = 6) were included. The patency of the shunt and the anatomy of intra-pericardial PA were evaluated by EBCT, and compared by angiography and echocardiography. EBCT accurately evaluated shunt patency and the anatomy of the intra-pericardial PA, except for the incorrect diagnosis of SVC-PA shunt patency and peripheral pulmonary stenosis in two TCPC patients. Both of these patients had bilateral SVC and received either bilateral BCPS or ligation of the left SVC respectively. The baffle between the IVC and PA was partly opacified through a fenestration of the baffle, but was not opacified in two patients without fenestration. EBCT accurately evaluated shunt patency and the anatomy of central PA, however, the accuracy was limited in two cases with bilateral SVC. The opacification of the intra-atrial baffle was insufficient in TCPC cases. Multi-phase CT angiography may overcome this limitation in this patient subset.

  10. Studies of material and process compatibility in developing compact silicon vapor chambers

    NASA Astrophysics Data System (ADS)

    Cai, Qingjun; Bhunia, Avijit; Tsai, Chialun; Kendig, Martin W.; DeNatale, Jeffrey F.

    2013-06-01

    The performance and long-term reliability of a silicon vapor chamber (SVC) developed for thermal management of high-power electronics critically depend on compatibility of the component materials. A hermetically sealed SVC presented in this paper is composed of bulk silicon, glass-frit as a bonding agent, lead/tin solder as an interface sealant and a copper charging tube. These materials, in the presence of a water/vapor environment, may chemically react and release noncondensable gas (NCG), which can weaken structural strength and degrade the heat transfer performance with time. The present work reports detailed studies on chemical compatibility of the components and potential solutions to avoid the resulting thermal performance degradation. Silicon surface oxidation and purification of operating liquid are necessary steps to reduce performance degradation in the transient period. A lead-based solder with its low reflow temperature is found to be electrochemically stable in water/vapor environment. High glazing temperature solidifies molecular bonding in glass-frit and mitigates PbO precipitation. Numerous liquid flushes guarantee removal of chemical residual after the charging tube is soldered to SVC. With these improvements on the SVC material and process compatibility, high effective thermal conductivity and steady heat transfer performance are obtained.

  11. NMR Study of the New Magnetic Superconductor CaK(Fe 0:951Ni0:049) 4As 4: Microscopic Coexistence of Hedgehog Spin-vortex Crystal and Superconductivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Q. P.; Meier, W. R.; Bohmer, A. E.

    Coexistence of a new-type antiferromagnetic (AFM) state, the so-called hedgehog spin-vortex crystal (SVC), and superconductivity (SC) is evidenced by 75As nuclear magnetic resonance study on single-crystalline CaK(Fe 0:951Ni0:049) 4As 4. The hedgehog SVC order is clearly demonstrated by the direct observation of the internal magnetic induction along the c axis at the As1 site (close to K) and a zero net internal magnetic induction at the As2 site (close to Ca) below an AFM ordering temperature T N ~ 52 K. The nuclear spin-lattice relaxation rate 1/T 1 shows a distinct decrease below T c ~ 10 K, providing alsomore » unambiguous evidence for the microscopic coexistence. Furthermore, based on the analysis of the 1/T 1 data, the hedgehog SVC-type spin correlations are found to be enhanced below T ~ 150 K in the paramagnetic state. Furthermore, these results indicate the hedgehog SVC-type spin correlations play an important role for the appearance of SC in the new magnetic superconductor.« less

  12. Vital capacity and COPD: the Swedish CArdioPulmonary bioImage Study (SCAPIS).

    PubMed

    Torén, Kjell; Olin, Anna-Carin; Lindberg, Anne; Vikgren, Jenny; Schiöler, Linus; Brandberg, John; Johnsson, Åse; Engström, Gunnar; Persson, H Lennart; Sköld, Magnus; Hedner, Jan; Lindberg, Eva; Malinovschi, Andrei; Piitulainen, Eeva; Wollmer, Per; Rosengren, Annika; Janson, Christer; Blomberg, Anders; Bergström, Göran

    2016-01-01

    Spirometric diagnosis of chronic obstructive pulmonary disease (COPD) is based on the ratio of forced expiratory volume in 1 second (FEV1)/vital capacity (VC), either as a fixed value <0.7 or below the lower limit of normal (LLN). Forced vital capacity (FVC) is a proxy for VC. The first aim was to compare the use of FVC and VC, assessed as the highest value of FVC or slow vital capacity (SVC), when assessing the FEV1/VC ratio in a general population setting. The second aim was to evaluate the characteristics of subjects with COPD who obtained a higher SVC than FVC. Subjects (n=1,050) aged 50-64 years were investigated with FEV1, FVC, and SVC after bronchodilation. Global Initiative for Chronic Obstructive Lung Disease (GOLD) COPDFVC was defined as FEV1/FVC <0.7, GOLDCOPDVC as FEV1/VC <0.7 using the maximum value of FVC or SVC, LLNCOPDFVC as FEV1/FVC below the LLN, and LLNCOPDVC as FEV1/VC below the LLN using the maximum value of FVC or SVC. Prevalence of GOLDCOPDFVC was 10.0% (95% confidence interval [CI] 8.2-12.0) and the prevalence of LLNCOPDFVC was 9.5% (95% CI 7.8-11.4). When estimates were based on VC, the prevalence became higher; 16.4% (95% CI 14.3-18.9) and 15.6% (95% CI 13.5-17.9) for GOLDCOPDVC and LLNCOPDVC, respectively. The group of additional subjects classified as having COPD based on VC, had lower FEV1, more wheeze and higher residual volume compared to subjects without any COPD. The prevalence of COPD was significantly higher when the ratio FEV1/VC was calculated using the highest value of SVC or FVC compared with using FVC only. Subjects classified as having COPD when using the VC concept were more obstructive and with indications of air trapping. Hence, the use of only FVC when assessing airflow limitation may result in a considerable under diagnosis of subjects with mild COPD.

  13. Accuracy of Intravenous Electrocardiography Confirmation of Peripherally Inserted Central Catheter for Parenteral Nutrition.

    PubMed

    Mundi, Manpreet S; Edakkanambeth Varayil, Jithinraj; McMahon, Megan T; Okano, Akiko; Vallumsetla, Nishanth; Bonnes, Sara L; Andrews, James C; Hurt, Ryan T

    2016-04-01

    Parenteral nutrition (PN) is a life-saving therapy for patients with intestinal failure. Safe delivery of hyperosmotic solution requires a central venous catheter (CVC) with tip in the lower superior vena cava (SVC) or at the SVC-right atrium (RA) junction. To reduce cost and delay in use of CVC, new techniques such as intravascular electrocardiogram (ECG) are being used for tip confirmation in place of chest x-ray (CXR). The present study assessed for accuracy of ECG confirmation in home PN (HPN). Records for all patients consulted for HPN from December 17, 2014, to June 16, 2015, were reviewed for patient demographics, diagnosis leading to HPN initiation, and ECG and CXR confirmation. CXRs were subsequently reviewed by a radiologist to reassess location of the CVC tip and identify those that should be adjusted. Seventy-three patients were eligible, and after assessment for research authorization and postplacement CXR, 17 patients (30% male) with an age of 54 ± 14 years were reviewed. In all patients, postplacement intravascular ECG reading stated tip in the SVC. However, based on CXR, the location of the catheter tip was satisfactory (low SVC or SVC-RA junction) in 10 of 17 patients (59%). Due to the high osmolality of PN, CVC tip location is of paramount importance. After radiology review of CXR, we noted that 7 of 17 (41%) peripherally inserted central catheter lines were in an unsatisfactory position despite ECG confirmation. With current data available, intravenous ECG confirmation should not be used as the sole source of tip confirmation in patients receiving HPN. © 2016 American Society for Parenteral and Enteral Nutrition.

  14. Superior vena cava syndrome with central venous catheter for chemotherapy treated successfully with fibrinolysis.

    PubMed

    Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R

    2007-03-01

    Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.

  15. The Use of HepRep in GLAST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perl, Joseph

    2003-07-10

    HepRep is a generic, hierarchical format for description of graphics representables that can be augmented by physics information and relational properties. It was developed for high energy physics event display applications and is especially suited to client/server or component frameworks. The GLAST experiment, an international effort led by NASA for a gamma-ray telescope to launch in 2006, chose HepRep to provide a flexible, extensible and maintainable framework for their event display without tying their users to any one graphics application. To support HepRep in their GUADI infrastructure, GLAST developed a HepRep filler and builder architecture. The architecture hides the detailsmore » of XML and CORBA in a set of base and helper classes allowing physics experts to focus on what data they want to represent. GLAST has two GAUDI services: HepRepSvc, which registers HepRep fillers in a global registry and allows the HepRep to be exported to XML, and CorbaSvc, which allows the HepRep to be published through a CORBA interface and which allows the client application to feed commands back to GAUDI (such as start next event, or run some GAUDI algorithm). GLAST's HepRep solution gives users a choice of client applications, WIRED (written in Java) or FRED (written in C++ and Ruby), and leaves them free to move to any future HepRep-compliant event display.« less

  16. 2014 Survivor Experience Survey: Report on Preliminary Results. Fiscal Year 2014, Quarter 4

    DTIC Science & Technology

    2014-12-01

    contact with the survivor, nor an ability to “track” or determine the survivor’s identity. The challenge , given the limitations noted above, was...was done primarily through SARCs, with additional support from UVAs/VAs and Special Victims’ Legal Counsels/Victims’ Legal Counsels (SVC/ VLC ). These...and SVC/ VLC to recruit their assistance in notifying eligible survivors about the survey effort and steps to obtain a ticket number without requiring

  17. Southern Vermont College (SVC) and Wheelock College (WC): 2010 Urban and Rural Healthcare Academy Program (HAP) for College Progress and Workforce Development

    ERIC Educational Resources Information Center

    DeCiccio, Albert C.

    2010-01-01

    (Purpose) This is a report about the Urban and Rural Healthcare Academy Pilot Program (HAP) that launched at Southern Vermont College (SVC) and Wheelock College (WC) in summer 2010. HAP enabled 18 vulnerable high school students to learn about how to progress to college, how to transition when they arrive on a college campus, and how to prepare…

  18. Characteristics of the road and surrounding environment in metropolitan shopping strips: association with the frequency and severity of single-vehicle crashes.

    PubMed

    Stephan, Karen L; Newstead, Stuart V

    2014-01-01

    Modeling crash risk in urban areas is more complicated than in rural areas due to the complexity of the environment and the difficulty obtaining data to fully characterize the road and surrounding environment. Knowledge of factors that impact crash risk and severity in urban areas can be used for countermeasure development and the design of risk assessment tools for practitioners. This research aimed to identify the characteristics of the road and roadside, surrounding environment, and sociodemographic factors associated with single-vehicle crash (SVC) frequency and severity in complex urban environments, namely, strip shopping center road segments. A comprehensive evidence-based list of data required for measuring the influence of the road, roadside, and other factors on crash risk was developed. The data included a broader range of factors than those traditionally considered in accident prediction models. One hundred and forty-two strip shopping segments located on arterial roads in metropolitan Melbourne, Australia, were identified. Police-reported casualty data were used to determine how many SVC occurred on the segments between 2005 and 2009. Data describing segment characteristics were collected from a diverse range of sources; for example, administrative government databases (traffic volume, speed limit, pavement condition, sociodemographic data, liquor licensing), detailed maps, on-line image sources, and digital images of arterial roads collected for the Victorian state road authority. Regression models for count data were used to identify factors associated with SVC frequency. Logistic regression was used to determine factors associated with serious and fatal outcomes. One hundred and seventy SVC occurred on the 142 selected road segments during the 5-year study period. A range of factors including traffic exposure, road cross section (curves, presence of median), road type, requirement for sharing the road with other vehicle types (trams and bicycles), roadside poles, and local amenities were associated with SVC frequency. A different set of risk factors was associated with the odds of a crash leading to a severe outcome: segment length, road cross section (curves, carriageway width), pavement condition, local amenities and vehicle, and driver factors. The presence of curves was the only factor associated with both SVC frequency and severity. A range of risk factors were associated with SVC frequency and severity in complex urban areas (metropolitan shopping strips), including traditionally studied characteristics such as traffic density and road design but also less commonly studied characteristics such as local amenities. Future behavioral research is needed to further investigate how and why these factors change the risk and severity of crashes before effective countermeasures can be developed.

  19. Application of an Adaptive Control Grid Interpolation Technique to Morphological Vascular Reconstruction: A Component of a Comprehensive Surgical Planning and Evaluation Tool

    DTIC Science & Technology

    2001-10-25

    a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV

  20. Preferential cephalic redistribution of left ventricular cardiac output during therapeutic hypothermia for perinatal hypoxic-ischemic encephalopathy.

    PubMed

    Hochwald, Ori; Jabr, Mohammad; Osiovich, Horacio; Miller, Steven P; McNamara, Patrick J; Lavoie, Pascal M

    2014-05-01

    To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3-4. LVCO was markedly reduced (mean ± SD 126 ± 38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88 ± 27 mL/kg/min) such that SVC flow represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 ± 13 vs 123 ± 17 beats/min; P < .001) compared with immediately postwarming in the context of myocardial dysfunction. Neonates with brain injury on magnetic resonance imaging had higher SVC flow prerewarming, compared with newborns without brain injury (P = .013). Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to-cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chibamore » needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.« less

  2. Comparison of right atrial pressure and central venous pressures measured at various anatomical locations in children.

    PubMed

    Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang

    2005-01-01

    To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.

  3. Risk Factors for Intracardiac Thrombosis in the Right Atrium and Superior Vena Cava in Critically Ill Neonates who Required the Installation of a Central Venous Catheter.

    PubMed

    Ulloa-Ricardez, Alfredo; Romero-Espinoza, Lizett; Estrada-Loza, María de Jesús; González-Cabello, Héctor Jaime; Núñez-Enríquez, Juan Carlos

    2016-08-01

    Central venous catheter (CVC) installation is essential for the treatment of critically ill neonates; however, it is associated with the development of neonatal intracardiac thrombosis, which is a complication that is associated with a poor prognosis. We aimed to identify specific risk factors for the development of intracardiac thrombosis in the right atrium (RA) and superior vena cava (SVC) related to the use of CVC in critically ill neonates. A case-control study was conducted at the tertiary referral neonatal intensive care unit of the Pediatric Hospital Siglo XXI in Mexico City, Mexico from 2008 to 2013. The included cases (n = 43) were de novo patients with intracardiac thrombosis in the RA and SVC diagnosed by echocardiography. The controls (n = 43) were neonates without intracardiac thrombosis or thrombosis at other sites. A logistic regression analysis was conducted, and odds ratios (ORs) and 95% confidence intervals (95% CIs) were calculated. The independent risk factors for intracardiac thrombosis in the RA and SVC were the surgical cut-down insertion technique (OR = 2.98; 95% CI: 1.18-9.10), a maternal history of gestational diabetes/diabetes mellitus (OR = 10.64; 95% CI: 1.13-121.41), Staphylococcus epidermidis infection (OR = 7.09; 95% CI: 1.09-45.92), and CVC placement in the SVC (OR = 5.77; 95% CI: 1.10-30.18). This study allowed us to identify several contributing factors to the development of intracardiac thrombosis in the RA and SVC related to the installation of a CVC in a subgroup of critically ill neonates. Multicenter and well-designed studies with a larger number of patients could help validate our findings and/or identify other risk factors that were not identified in the present study. Copyright © 2015. Published by Elsevier B.V.

  4. Hypocalcemic stimulation and nonselective venous sampling for localizing parathyroid adenomas: work in progress.

    PubMed

    Doppman, J L; Skarulis, M C; Chang, R; Alexander, H R; Bartlett, D; Libutti, S K; Marx, S J; Spiegel, A M

    1998-07-01

    To evaluate whether the release of parathyroid hormone (PTH) from parathyroid tumors during selective parathyroid arteriography can help localize the tumors. In 20 patients (six men, 14 women; age range, 24-72 years) with parathyroid tumors undergoing parathyroid arteriography after failed surgery, serial measurements of PTH were obtained during selective arteriography with nonionic contrast material. PTH levels were measured in the superior vena cava (SVC) before and at varying times from 20 to 120 seconds after arteriography. A 1.4-fold increase in the PTH level of the postarteriographic SVC samples enabled correct prediction of the site of adenoma in 13 of the 20 patients (65%). Of nine patients with positive arteriograms, eight had positive results of postarteriographic sampling. Of 11 patients with negative arteriograms, five had positive results of postarteriographic sampling. Sampling the SVC for PTH gradients after selective parathyroid arteriography correctly indicated the site of the adenoma in 13 of 20 patients (65%).

  5. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less

  6. The use of portable video media vs standard verbal communication in the urological consent process: a multicentre, randomised controlled, crossover trial.

    PubMed

    Winter, Matthew; Kam, Jonathan; Nalavenkata, Sunny; Hardy, Ellen; Handmer, Marcus; Ainsworth, Hannah; Lee, Wai Gin; Louie-Johnsun, Mark

    2016-11-01

    To determine if portable video media (PVM) improves patient's knowledge and satisfaction acquired during the consent process for cystoscopy and insertion of a ureteric stent compared to standard verbal communication (SVC), as informed consent is a crucial component of patient care and PVM is an emerging technology that may help improve the consent process. In this multi-centre randomised controlled crossover trial, patients requiring cystoscopy and stent insertion were recruited from two major teaching hospitals in Australia over a 15-month period (July 2014-December 2015). Patient information delivery was via PVM and SVC. The PVM consisted of an audio-visual presentation with cartoon animation presented on an iPad. Patient satisfaction was assessed using the validated Client Satisfaction Questionnaire 8 (CSQ-8; maximum score 32) and knowledge was tested using a true/false questionnaire (maximum score 28). Questionnaires were completed after first intervention and after crossover. Scores were analysed using the independent samples t-test and Wilcoxon signed-rank test for the crossover analysis. In all, 88 patients were recruited. A significant 3.1 point (15.5%) increase in understanding was demonstrable favouring the use of PVM (P < 0.001). There was no difference in patient satisfaction between the groups as judged by the CSQ-8. A significant 3.6 point (17.8%) increase in knowledge score was seen when the SVC group were crossed over to the PVM arm. A total of 80.7% of patients preferred PVM and 19.3% preferred SVC. Limitations include the lack of a validated questionnaire to test knowledge acquired from the interventions. This study demonstrates patients' preference towards PVM in the urological consent process of cystoscopy and ureteric stent insertion. PVM improves patient's understanding compared with SVC and is a more effective means of content delivery to patients in terms of overall preference and knowledge gained during the consent process. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  7. Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans.

    PubMed

    Neuzil, Petr; Reddy, Vivek Y; Merkely, Bela; Geller, Laszlo; Molnar, Levente; Bednarek, Jacek; Bartus, Krzysztof; Richey, Mark; Bsee, T J Ransbury; Sanders, William E

    2014-02-01

    A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). The intravascular defibrillator has DFTs similar to those of commercially available ICDs. Published by Heart Rhythm Society on behalf of Heart Rhythm Society.

  8. Right Site, Wrong Route - Cannulating the Left Internal Jugular Vein.

    PubMed

    Paik, Peter; Arukala, Sanjay K; Sule, Anupam A

    2018-01-09

    Central venous catheters are placed in approximately five million patients annually in the US. The preferred site of insertion is one with fewer risks and easier access. Although the right internal jugular vein is preferred, on occasion, the left internal jugular may have to be accessed. A patient was admitted for septic shock, cerebrovascular accident, and non-ST-segment elevation myocardial infarction. A central venous line was needed for antibiotic and vasopressor administration. Due to trauma from a fall to the right side and previously failed catheterization attempts at the left subclavian and femoral veins, the left internal jugular vein was accessed. On chest radiography for confirmation, the left internal jugular central venous catheter was seen projecting down the left paraspinal region. It did not take the expected course across the midline toward the right and into the superior vena cava (SVC). A review of a computed tomography (CT) scan of the chest with contrast done on a prior admission revealed a duplicated SVC on the left side that had not been reported in the original CT scan interpretation. A left-sided SVC is present in approximately 0.3% to 0.5% of the population, with 90% of these draining into the coronary sinus. During placements of central venous lines and pacemakers, irritation of the coronary sinus may result in hypotension, arrhythmia, myocardial ischemia, or cardiac arrest. A widened mediastinum can be an indication of a duplicated SVC. When attempting a left internal jugular vein central venous catheter placement, it is important to be aware of venous anomalies in order to prevent complications.

  9. Relationship between lung function and grip strength in older hospitalized patients: a pilot study

    PubMed Central

    Holmes, Sarah J; Allen, Stephen C; Roberts, Helen C

    2017-01-01

    Objective Older people with reduced respiratory muscle strength may be misclassified as having COPD on the basis of spirometric results. We aimed to evaluate the relationship between lung function and grip strength in older hospitalized patients without known airways disease. Methods Patients in acute medical wards were recruited who were aged ≥70 years; no history, symptoms, or signs of respiratory disease; Mini Mental State Examination ≥24; willing and able to consent to participate; and able to perform hand grip and forced spirometry. Data including lung function (forced expiratory volume in 1 second [FEV1], forced vital capacity [FVC], FEV1/FVC, peak expiratory flow rate [PEFR], and slow vital capacity [SVC]), grip strength, age, weight, and height were recorded. Data were analyzed using descriptive statistics and linear regression unadjusted and adjusted (for age, height, and weight). Results A total of 50 patients (20 men) were recruited. Stronger grip strength in men was significantly associated with greater FEV1, but this was attenuated by adjustment for age, height, and weight. Significant positive associations were found in women between grip strength and both PEFR and SVC, both of which remained robust to adjustment. Conclusion The association between grip strength and PEFR and SVC may reflect stronger patients generating higher intrathoracic pressure at the start of spirometry and pushing harder against thoracic cage recoil at end-expiration. Conversely, patients with weaker grip strength had lower PEFR and SVC. These patients may be misclassified as having COPD on the basis of spirometric results. PMID:28458532

  10. Single-Coil Defibrillator Leads Yield Satisfactory Defibrillation Safety Margin in Hypertrophic Cardiomyopathy.

    PubMed

    Okamura, Hideo; Friedman, Paul A; Inoue, Yuko; Noda, Takashi; Aiba, Takeshi; Yasuda, Satoshi; Ogawa, Hisao; Kamakura, Shiro; Kusano, Kengo; Espinosa, Raul E

    2016-09-23

    Single-coil defibrillator leads have gained favor because of their potential ease of extraction. However, a high defibrillation threshold remains a concern in patients with hypertrophic cardiomyopathy (HCM), and in many cases, dual-coil leads have been used for this patient group. There is little data on using single-coil leads for HCM patients. We evaluated 20 patients with HCM who received an implantable cardioverter-defibrillator (ICD) on the left side in combination with a dual-coil lead. Two sets of defibrillation tests were performed in each patient, one with the superior vena cava (SVC) coil "on" and one with the SVC coil "off". ICDs were programmed to deliver 25 joules (J) for the first attempt followed by maximum energy (35 J or 40 J). Shock impedance and shock pulse width at 25 J in each setting as well as the results of the shock were analyzed. All 25-J shocks in both settings successfully terminated ventricular fibrillation. However, shock impedance and pulse width increased substantially with the SVC coil programmed "off" compared with "on" (66.4±6.1 ohm and 14.0±1.3 ms "off" vs. 41.9±5.0 ohm and 9.3±0.8 ms "on", P<0.0001 respectively). Biphasic 25-J shocks with the SVC coil 'off' successfully terminated ventricular fibrillation in HCM patients, indicating a satisfactory safety margin for 35-J devices. Single-coil leads appear appropriate for left-sided implantation in this patient group. (Circ J 2016; 80: 2199-2203).

  11. Hedgehog spin-vortex crystal stabilized in a hole-doped iron-based superconductor

    DOE PAGES

    Meier, William R.; Ding, Qing-Ping; Kreyssig, Andreas; ...

    2018-02-09

    Magnetism is widely considered to be a key ingredient of unconventional superconductivity. In contrast to cuprate high-temperature superconductors, antiferromagnetism in most Fe-based superconductors (FeSCs) is characterized by a pair of magnetic propagation vectors, (π,0) and (0,π). Consequently, three different types of magnetic order are possible. Of these, only stripe-type spin-density wave (SSDW) and spin-charge-density wave (SCDW) orders have been observed. A realization of the proposed spin-vortex crystal (SVC) order is noticeably absent. We report a magnetic phase consistent with the hedgehog variation of SVC order in Ni-doped and Co-doped CaKFe 4As 4 based on thermodynamic, transport, structural and local magneticmore » probes combined with symmetry analysis. The exotic SVC phase is stabilized by the reduced symmetry of the CaKFe 4As 4 structure. Thus, our results suggest that the possible magnetic ground states in FeSCs have very similar energies, providing an enlarged configuration space for magnetic fluctuations to promote high-temperature superconductivity.« less

  12. Hedgehog spin-vortex crystal stabilized in a hole-doped iron-based superconductor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, William R.; Ding, Qing-Ping; Kreyssig, Andreas

    Magnetism is widely considered to be a key ingredient of unconventional superconductivity. In contrast to cuprate high-temperature superconductors, antiferromagnetism in most Fe-based superconductors (FeSCs) is characterized by a pair of magnetic propagation vectors, (π,0) and (0,π). Consequently, three different types of magnetic order are possible. Of these, only stripe-type spin-density wave (SSDW) and spin-charge-density wave (SCDW) orders have been observed. A realization of the proposed spin-vortex crystal (SVC) order is noticeably absent. We report a magnetic phase consistent with the hedgehog variation of SVC order in Ni-doped and Co-doped CaKFe 4As 4 based on thermodynamic, transport, structural and local magneticmore » probes combined with symmetry analysis. The exotic SVC phase is stabilized by the reduced symmetry of the CaKFe 4As 4 structure. Thus, our results suggest that the possible magnetic ground states in FeSCs have very similar energies, providing an enlarged configuration space for magnetic fluctuations to promote high-temperature superconductivity.« less

  13. Anatomic bifurcated reconstruction of chronic bilateral innominate-superior vena cava occlusion using the Y-stenting technique.

    PubMed

    Amin, Parth; Sharafuddin, Mel J; Laurich, Chad; Nicholson, Rachael M; Sun, Raphael C; Roh, Simon; Kresowik, Timothy F; Sharp, William J

    2012-02-01

    This article presents the case of a 42-year-old man who presented with superior vena cava (SVC) syndrome due to fibrosing mediastinitis with multiple failed attempts at recanalization. We initially treated him with unilateral sharp needle recanalization of the right innominate vein into the SVC stump followed by stenting. Although his symptoms improved immediately, they did not completely resolve. Six months later, he returned with worsening symptoms, and venography revealed in-stent restenosis. The patient requested simultaneous treatment on the left side. The right stent was dilated, and a 3-cm-long occlusion of the left innominate vein was recanalized, again using sharp needle technique, homing into the struts of the right-sided stent. Following fenestration of the stent, a second stent was deployed from the left side into the SVC, and the two Y limbs were sequentially dilated to allow a true bifurcation anatomy (figure). The patient had complete resolution of his symptoms and continues to do well 6 months later. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  14. Effect of excess pore pressure on the long runout of debris flows over low gradient channels: A case study of the Dongyuege debris flow in Nu River, China

    NASA Astrophysics Data System (ADS)

    Zhou, Zhen-Hua; Ren, Zhe; Wang, Kun; Yang, Kui; Tang, Yong-Jun; Tian, Lin; Xu, Ze-Min

    2018-05-01

    Debris flows with long reaches are one of the major natural hazards to human life and property on alluvial fans, as shown by the debris flow that occurred in the Dongyuege (DYG) Gully in August 18, 2010, and caused 96 deaths. The travel distance and the runout distance of the DYG large-scale tragic debris flow were 11 km and 9 km, respectively. In particular, the runout distance over the low gradient channel (channel slope < 5°) upstream of the depositional fan apex reached up to 3.3 km. The build-up and maintenance of excess pore pressure in the debris-flow mass might have played a crucial role in the persistence and long runout of the bouldery viscous debris flow. Experiments to measure pore pressure and pore water escape have been carried out by reconstituting the debris flow bodies with the DYG debris flow deposit. The slurrying of the debris is governed by solid volumetric concentration (SVC), and the difference between the lower SVC limit and the upper SVC limit can be defined as debris flow index (Id). Peak value (Kp) and rate of dissipation (R) of relative excess pore pressure are dependent on SVC. Further, the SVC that gives the lowest rate of dissipation is regarded as the optimum SVC (Cvo). The dissipation response of excess pore pressure can be characterized by the R value under Cvo at a given moment (i.e., 0.5 h, 1 h or 2 h later after peak time). The results reveal that a relatively high level of excess pore pressure developed within the DYG debris-flow mass and had a strong persistence capability. Further research shows that the development, peak value and dissipation of excess pore pressure in a mixture of sediment and water are related to the maximum grain size (MGS), gradation and mineralogy of clay-size particles of the sediment. The layer-lattice silicates in clay particles can be the typical clay minerals, including kaolinite, montmorillonite and illite, and also the unrepresentative clay minerals such as muscovite and chlorite. Moreover, small woody debris can also contribute to the slurrying of sediments and maintenance of debris flows in well vegetated mountainous areas and the boulders suspended in debris flows can elevate excess pore pressure and extend debris-flow mobility. The parameters, including Id, Kp, R and etc., are affected by the intrinsic properties of debris. They, therefore, can reflect the slurrying susceptibility of sediments, and can also be applied to the research on the occurrence mechanisms and risk assessment of other debris flows.

  15. Identification of temporal variations in mental workload using locally-linear-embedding-based EEG feature reduction and support-vector-machine-based clustering and classification techniques.

    PubMed

    Yin, Zhong; Zhang, Jianhua

    2014-07-01

    Identifying the abnormal changes of mental workload (MWL) over time is quite crucial for preventing the accidents due to cognitive overload and inattention of human operators in safety-critical human-machine systems. It is known that various neuroimaging technologies can be used to identify the MWL variations. In order to classify MWL into a few discrete levels using representative MWL indicators and small-sized training samples, a novel EEG-based approach by combining locally linear embedding (LLE), support vector clustering (SVC) and support vector data description (SVDD) techniques is proposed and evaluated by using the experimentally measured data. The MWL indicators from different cortical regions are first elicited by using the LLE technique. Then, the SVC approach is used to find the clusters of these MWL indicators and thereby to detect MWL variations. It is shown that the clusters can be interpreted as the binary class MWL. Furthermore, a trained binary SVDD classifier is shown to be capable of detecting slight variations of those indicators. By combining the two schemes, a SVC-SVDD framework is proposed, where the clear-cut (smaller) cluster is detected by SVC first and then a subsequent SVDD model is utilized to divide the overlapped (larger) cluster into two classes. Finally, three-class MWL levels (low, normal and high) can be identified automatically. The experimental data analysis results are compared with those of several existing methods. It has been demonstrated that the proposed framework can lead to acceptable computational accuracy and has the advantages of both unsupervised and supervised training strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Fluoroscopy of spontaneous breathing is more sensitive than phrenic nerve stimulation for detection of right phrenic nerve injury during cryoballoon ablation of atrial fibrillation.

    PubMed

    Linhart, Markus; Nielson, Annika; Andrié, René P; Mittmann-Braun, Erica L; Stöckigt, Florian; Kreuz, Jens; Nickenig, Georg; Schrickel, Jan W; Lickfett, Lars M

    2014-08-01

    Right phrenic nerve palsy (PNP) is a typical complication of cryoballoon ablation of the right-sided pulmonary veins (PVs). Phrenic nerve function can be monitored by palpating the abdomen during phrenic nerve pacing from the superior vena cava (SVC pacing) or by fluoroscopy of spontaneous breathing. We sought to compare the sensitivity of these 2 techniques during cryoballoon ablation for detection of PNP. A total of 133 patients undergoing cryoballoon ablation were monitored with both SVC pacing and fluoroscopy of spontaneous breathing during ablation of the right superior PV. PNP occurred in 27/133 patients (20.0%). Most patients (89%) had spontaneous recovery of phrenic nerve function at the end of the procedure or on the following day. Three patients were discharged with persistent PNP. All PNP were detected first by fluoroscopic observation of diaphragm movement during spontaneous breathing, while diaphragm could still be stimulated by SVC pacing. In patients with no recovery until discharge, PNP occurred at a significantly earlier time (86 ± 34 seconds vs. 296 ± 159 seconds, P < 0.001). No recovery occurred in 2/4 patients who were ablated with a 23 mm cryoballoon as opposed to 1/23 patients with a 28 mm cryoballoon (P = 0.049). Fluoroscopic assessment of diaphragm movement during spontaneous breathing is more sensitive for detection PNP as compared to SVC pacing. PNP as assessed by fluoroscopy is frequent (20.0%) and carries a high rate of recovery (89%) until discharge. Early onset of PNP and use of 23 mm cryoballoon are associated with PNP persisting beyond hospital discharge. © 2014 Wiley Periodicals, Inc.

  17. Evaluation of blood flow distribution asymmetry and vascular geometry in patients with Fontan circulation using 4-D flow MRI

    PubMed Central

    Jarvis, Kelly; Schnell, Susanne; Barker, Alex J.; Garcia, Julio; Lorenz, Ramona; Rose, Michael; Chowdhary, Varun; Carr, James; Robinson, Joshua D.; Rigsby, Cynthia K.; Markl, Michael

    2016-01-01

    Background Asymmetrical caval to pulmonary blood flow is suspected to cause complications in patients with Fontan circulation. The aim of this study was to test the feasibility of 4-D flow MRI for characterizing the relationship between 3-D blood flow distribution and vascular geometry. Objective We hypothesized that both flow distribution and geometry can be calculated with low interobserver variability and will detect a direct relationship between flow distribution and Fontan geometry. Materials and methods Four-dimensional flow MRI was acquired in 10 Fontan patients (age: 16±4 years [mean ± standard deviation; range 9–21 years]). The Fontan connection was isolated by 3-D segmentation to evaluate flow distribution from the inferior vena cava (IVC) and superior vena cava (SVC) to the left and right pulmonary arteries (LPA, RPA) and to characterize geometry (cross-sectional area, caval offset, vessel angle). Results Flow distribution results indicated SVC flow tended toward the RPA while IVC flow was more evenly distributed (SVC to RPA: 78%±28 [9–100], IVC to LPA: 54%±28 [4–98]). There was a significant relationship between pulmonary artery cross-sectional area and flow distribution (IVC to RPA: R2=0.50, P=0.02; SVC to LPA: R2=0.81, P=0.0004). Good agreement was found between observers and for flow distribution when compared to net flow values. Conclusion Four-dimensional (4-D) flow MRI was able to detect relationships between flow distribution and vessel geometry. Future studies are warranted to investigate the potential of patient specific hemodynamic analysis to improve diagnostic capability. PMID:27350377

  18. Vertebral Uptake of Tc-99m Macroaggregated Albumin (MAA) with SPECT/CT Occurring in Superior Vena Cava Obstruction.

    PubMed

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma

    2016-09-01

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  19. Gas chimney detection based on improving the performance of combined multilayer perceptron and support vector classifier

    NASA Astrophysics Data System (ADS)

    Hashemi, H.; Tax, D. M. J.; Duin, R. P. W.; Javaherian, A.; de Groot, P.

    2008-11-01

    Seismic object detection is a relatively new field in which 3-D bodies are visualized and spatial relationships between objects of different origins are studied in order to extract geologic information. In this paper, we propose a method for finding an optimal classifier with the help of a statistical feature ranking technique and combining different classifiers. The method, which has general applicability, is demonstrated here on a gas chimney detection problem. First, we evaluate a set of input seismic attributes extracted at locations labeled by a human expert using regularized discriminant analysis (RDA). In order to find the RDA score for each seismic attribute, forward and backward search strategies are used. Subsequently, two non-linear classifiers: multilayer perceptron (MLP) and support vector classifier (SVC) are run on the ranked seismic attributes. Finally, to capitalize on the intrinsic differences between both classifiers, the MLP and SVC results are combined using logical rules of maximum, minimum and mean. The proposed method optimizes the ranked feature space size and yields the lowest classification error in the final combined result. We will show that the logical minimum reveals gas chimneys that exhibit both the softness of MLP and the resolution of SVC classifiers.

  20. A Case of Multiple Cardiovascular and Tracheal Anomalies Presented with Wolff-Parkinson-White Syndrome in a Middle-aged Adult.

    PubMed

    Shi, Hyejin; Sohn, Sungmin; Wang, SungHo; Park, Sungrock; Lee, SangKi; Kim, Song Yi; Jeong, Sun Young; Kim, Changhwan

    2017-12-01

    Congenital cardiovascular anomalies, such as dextrocardia, persistent left superior vena cava (SVC), and pulmonary artery (PA) sling, are rare disorders. These congenital anomalies can occur alone, or coincide with other congenital malformations. In the majority of cases, congenital anomalies are detected early in life by certain signs and symptoms. A 56-year-old man with no previous medical history was admitted due to recurrent wide QRS complex tachycardia with hemodynamic collapse. A chest radiograph showed dextrocardia. After synchronized cardioversion, an electrocardiogram revealed Wolff-Parkinson-White (WPW) syndrome. Persistent left SVC, PA sling, and right tracheal bronchus were also detected by a chest computed tomography (CT) scan. He was diagnosed with paroxysmal supraventricular tachycardia (PSVT) associated with WPW syndrome, and underwent radiofrequency ablation. We reported the first case of situs solitus dextrocardia coexisting with persistent left SVC, PA sling and right tracheal bronchus presented with WPW and PSVT in a middle-aged adult. In patients with a cardiovascular anomaly, clinicians should consider thorough evaluation of possibly combined cardiovascular and airway malformations and cardiac dysrhythmia. © 2017 The Korean Academy of Medical Sciences.

  1. Isolation of a rhabdovirus during outbreaks of disease in cyprinid fish species at fishery sites in England.

    PubMed

    Way, K; Bark, S J; Longshaw, C B; Denham, K L; Dixon, P F; Feist, S W; Gardiner, R; Gubbins, M J; Le Deuff, R M; Martin, P D; Stone, D M; Taylor, G R

    2003-12-03

    A virus was isolated during disease outbreaks in bream Abramis brama, tench Tinca tinca, roach Rutilis rutilis and crucian carp Carassius carassius populations at 6 fishery sites in England in 1999. Mortalities at the sites were primarily among recently introduced fish and the predominant fish species affected was bream. The bream stocked at 5 of the 6 English fishery sites were found to have originated from the River Bann, Northern Ireland. Most fish presented few consistent external signs of disease but some exhibited clinical signs similar to those of spring viraemia of carp (SVC), with extensive skin haemorrhages, ulceration on the flanks and internal signs including ascites and petechial haemorrhages. The most prominent histopathological changes were hepatocellular necrosis, interstitial nephritis and splenitis. The virus induced a cytopathic effect in tissue cultures (Epithelioma papulosum cyprini [EPC] cells) at 20 degrees C and produced moderate signals in an enzyme immunoassay (EIA) for the detection of SVC virus. The virus showed a close serological relationship to pike fry rhabdovirus in both EIA and serum neutralisation assays and to a rhabdovirus isolated during a disease outbreak in a bream population in the River Bann in 1998. A high degree of sequence similarity (> or = 99.5% nucleotide identity) was observed between the English isolates and those from the River Bann. Experimental infection of juvenile bream, tench and carp with EPC cell-grown rhabdovirus by bath and intraperitoneal injection resulted in a 40% mortality of bream in the injection group only. The virus was re-isolated from pooled kidney, liver and spleen tissue samples from moribund bream. The field observations together with the experimental results indicate that this rhabdovirus is of low virulence but may have the potential to cause significant mortality in fishes under stress.

  2. Bidirectional Glenn on cardiopulmonary bypass: A comparison of three techniques.

    PubMed

    Talwar, Sachin; Kumar, Manikala Vinod; Nehra, Ashima; Malhotra Kapoor, Poonam; Makhija, Neeti; Sreenivas, Vishnubhatla; Choudhary, Shiv Kumar; Airan, Balram

    2017-05-01

    To analyze the intraoperative and early results of the bidirectional Glenn (BDG) procedure performed on cardiopulmonary bypass (CPB) using three different techniques. Between September 2013 and June 2015, 75 consecutive patients (mean age 42 ± 34.4 months) undergoing BDG were randomly assigned to either technique I: open anastomosis or technique II: superior vena cava (SVC) cannulation or technique III: intermittent SVC clamping. We monitored the cerebral near infrared spectrophotometry (NIRS), SVC pressure, CPB time, intensive care unit (ICU) stay, and neurocognitive function. Patients in technique III had abnormal lower NIRS values during the procedure (57 ± 7.4) compared to techniques I and II (64 ± 7.5 and 61 ± 8.0, P = 0.01). Postoperative SVC pressure in technique III was higher than other two groups (17.6 ± 3.7 mmHg vs. 14.2 ± 3.5 mmHg and 15.3 ± 2.0 mmHg in techniques I and II, respectively = 0.0008). CPB time was highest in technique II (44 ± 18 min) compared to techniques I and III (29 ± 14 min and 38 ± 16 min, P = 0.006), respectively. ICU stay was longer in technique III (30 ± 15 h) compared to the other two techniques (22 ± 8.5 h and 27 ± 8.3 h in techniques I and II, respectively = 0.04). No patient experienced significant neurocognitive dysfunction. All techniques of BDG provided acceptable results. The open technique was faster and its use in smaller children merits consideration. The technique of intermittent clamping should be used as a last resort. © 2017 Wiley Periodicals, Inc.

  3. Dual role of cerebral blood flow in regional brain temperature control in the healthy newborn infant.

    PubMed

    Iwata, Sachiko; Tachtsidis, Ilias; Takashima, Sachio; Matsuishi, Toyojiro; Robertson, Nicola J; Iwata, Osuke

    2014-10-01

    Small shifts in brain temperature after hypoxia-ischaemia affect cell viability. The main determinants of brain temperature are cerebral metabolism, which contributes to local heat production, and brain perfusion, which removes heat. However, few studies have addressed the effect of cerebral metabolism and perfusion on regional brain temperature in human neonates because of the lack of non-invasive cot-side monitors. This study aimed (i) to determine non-invasive monitoring tools of cerebral metabolism and perfusion by combining near-infrared spectroscopy and echocardiography, and (ii) to investigate the dependence of brain temperature on cerebral metabolism and perfusion in unsedated newborn infants. Thirty-two healthy newborn infants were recruited. They were studied with cerebral near-infrared spectroscopy, echocardiography, and a zero-heat flux tissue thermometer. A surrogate of cerebral blood flow (CBF) was measured using superior vena cava flow adjusted for cerebral volume (rSVC flow). The tissue oxygenation index, fractional oxygen extraction (FOE), and the cerebral metabolic rate of oxygen relative to rSVC flow (CMRO₂ index) were also estimated. A greater rSVC flow was positively associated with higher brain temperatures, particularly for superficial structures. The CMRO₂ index and rSVC flow were positively coupled. However, brain temperature was independent of FOE and the CMRO₂ index. A cooler ambient temperature was associated with a greater temperature gradient between the scalp surface and the body core. Cerebral oxygen metabolism and perfusion were monitored in newborn infants without using tracers. In these healthy newborn infants, cerebral perfusion and ambient temperature were significant independent variables of brain temperature. CBF has primarily been associated with heat removal from the brain. However, our results suggest that CBF is likely to deliver heat specifically to the superficial brain. Further studies are required to assess the effect of cerebral metabolism and perfusion on regional brain temperature in low-cardiac output conditions, fever, and with therapeutic hypothermia. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Blanche, Alain F.; Pautas, Eric; Gouin, Isabelle

    Purpose. To evaluate routine use of access sites in the arm for percutaneous caval filter placement (PCFP) in elderly patients. Neck arthritis, patient anxiety, access site thrombosis or fecal/urinary incontinence complicating jugular or femoral access may require alternative access sites in this population. Methods. Access via the right arm was chosen for PCFP (VenaTech LP). The indication for PCFP was deep vein thrombosis, a history of pulmonary embolism, and a contraindication to anticoagulant therapy. Ultrasound-guided puncture was performed after diameter measurement of the arm veins (O{sub AV}). The filter was inserted with standard imaging procedures. Procedural difficulty was graded andmore » compared with O{sub AV} and the angle from the arm vein to the superior vena cava ({alpha}{sub AV/SVC}). Results. Over 2 years, 16 patients (14 women, 2 men) with an average age of 90 years (range 79-97 years) were included in the study. The average O{sub AV} value of the basilic or brachial veins was 4.2 mm (range 3.0-5.1 mm). The minimal O{sub AV} for successful access was determined after the first 15 patients. No hematoma occurred at the puncture sites. The average {alpha}{sub AV/SVC} value was 62 deg. (range 29 deg. - 90 deg.). Arm access was possible in 12 of 16 patients (75%) with O{sub AV} {>=} 3.5 mm and {alpha}{sub AV/SVC} {>=} 29 deg. Every procedure via the arm was graded 'easy' by the operator, regardless of angulation values. Femoral access was used in one case due to the impossibility of traversing the heart (patient no. 2), and jugular access was used in 3 of 16 (19%) patients due to puncture failure (patient no. 4), small O{sub AV} (3 mm) (patient no. 6), and stenosis of the distal right subclavian vein (patient no.16), respectively. Conclusion. PCFP via the arm can be routinely accomplished in patients older than 75 years, provided O{sub AV} {>=} 3.5 mm, and {alpha}{sub AV/SVC} {>=} 200119 d.« less

  5. The relationship between BNP, NTproBNP and echocardiographic measurements of systemic blood flow in very preterm infants.

    PubMed

    König, K; Guy, K J; Walsh, G; Drew, S M; Watkins, A; Barfield, C P

    2014-04-01

    Preterm infants are at risk of circulatory compromise following birth. Functional neonatal echocardiography including superior vena cava (SVC) flow is increasingly used in neonatal medicine, and low SVC flow has been associated with adverse outcome. However, echocardiography is not readily available in many neonatal units and B-type natriuretic peptides (BNPs) may be useful in guiding further cardiovascular assessment. This study investigated the relationship between BNP, N-terminal pro-BNP (NTproBNP) and echocardiographic measurements of systemic blood flow in very preterm infants. This is a prospective observational study. Sixty preterm infants <32 weeks gestational age were included after the treating neonatologist had requested an echocardiogram for suspected cardiovascular compromise. BNP and NTproBNP were sampled just before the echocardiogram. Echocardiographic examination included fractional shortening (FS), SVC flow, left and right ventricular output (LVO and RVO). Statistical analysis included simple linear regression of BNP and NTproBNP with echocardiographic measures and multiple regression including potential confounding variables. Mean (s.d.) gestational age at birth was 27(5) (2(1)) weeks, median (interquartile range, IQR) birth weight was 995 (845 to 1175) grams. Neither BNP nor NTproBNP correlated with SVC flow (BNP 95% confidence interval (CI) -0.0014 to 0.013, P=0.12; NTproBNP 95% CI -0.00069 to 0.01, P=0.085); LVO (BNP 95% CI -0.00078 to 0.0072, P=0.11; NTproBNP 95% CI -0.0034 to 0.0034, P=0.99); RVO (BNP 95% CI -0.00066 to 0.0058, P=0.12; NTproBNP 95% CI -0.0012 to 0.0044, P=0.25); or FS (BNP 95% CI -0.053 to 0.051, P=0.96; NTproBNP 95% CI -0.061 to 0.019, P=0.3). Multivariate linear regression did not significantly alter results. In this cohort of very preterm infants, BNP and NTproBNP did not correlate with echocardiographic measurements of systemic blood flow within the first 72 h of life.

  6. Experimental Investigation for Fault Diagnosis Based on a Hybrid Approach Using Wavelet Packet and Support Vector Classification

    PubMed Central

    Li, Pengfei; Jiang, Yongying; Xiang, Jiawei

    2014-01-01

    To deal with the difficulty to obtain a large number of fault samples under the practical condition for mechanical fault diagnosis, a hybrid method that combined wavelet packet decomposition and support vector classification (SVC) is proposed. The wavelet packet is employed to decompose the vibration signal to obtain the energy ratio in each frequency band. Taking energy ratios as feature vectors, the pattern recognition results are obtained by the SVC. The rolling bearing and gear fault diagnostic results of the typical experimental platform show that the present approach is robust to noise and has higher classification accuracy and, thus, provides a better way to diagnose mechanical faults under the condition of small fault samples. PMID:24688361

  7. Preferential cephalic redistribution of left ventricular cardiac output during therapeutic hypothermia for perinatal hypoxic-ischemic encephalopathy

    PubMed Central

    Hochwald, Ori; Jabr, Mohammed; Osiovich, Horacio; Miller, Steven P.; McNamara, Patrick J.; Lavoie, Pascal M.

    2015-01-01

    Objective To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Study design Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had a cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3–4. Results LVCO was markedly reduced (mean+/−SD: 126+/−38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88+/− 27 mL/kg/min) such that it represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 +/− 13 BPM versus 123 +/− 17 BPM; p<0.001) compared to immediately post-warming, in the context of myocardial dysfunction. Neonates with documented brain injury on MRI showed higher SVC flow pre-rewarming, compared to newborns without brain injury (p=0.013). Conclusion Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. PMID:24582011

  8. A rational design for hepatitis B virus X protein refolding and bioprocess development guided by second virial coefficient studies.

    PubMed

    Basu, Anindya; Chen, Wei Ning; Leong, Susanna Su Jan

    2011-04-01

    The hepatitis B virus X (HBx) protein is well known for its role in hepatitis B virus infection that often leads to hepatocellular carcinoma. Despite the clinical importance of HBx, there is little progress in anti-HBx drug development strategies due to shortage of HBx from native sources. Consistent expression of HBx as insoluble inclusion bodies within various expression systems has largely hindered HBx manufacturing via economical biosynthesis routes. Confronted by this roadblock, this study aims to quantitatively understand HBx protein behaviour in solution that will guide the rational development of a refolding-based bioprocess for HBx production. Second virial coefficient (SVC) measurements were employed to study the effects of varying physicochemical parameters on HBx intermolecular protein interaction. The SVC results suggest that covalent HBx aggregates play a key role in protein destabilisation during refolding. The use of an SVC-optimised refolding environment yielded bioactive and soluble HBx proteins from the denatured-reduced inclusion body state. This study provides new knowledge on HBx solubility behaviour in vitro, which is important in structure-function elucidation behaviour of this hydrophobic protein. Importantly, a rational refolding-based Escherichia coli bioprocess that can deliver purified and soluble HBx at large scale is successfully developed, which opens the way for rapid preparation of soluble HBx for further clinical and characterisation studies.

  9. Pathogenesis of spring viremia of carp virus in emerald shiner Notropis atherinoides Rafinesque, fathead minnow Pimephales promelas Rafinesque and white sucker Catostomus commersonii (Lacepede).

    PubMed

    Misk, E; Garver, K; Nagy, E; Isaac, S; Tubbs, L; Huber, P; Al-Hussinee, L; Lumsden, J S

    2016-06-01

    Spring viremia of carp (SVC) is a reportable disease to the World Organization of Animal Health (OIE) as it is known to cause significant international economic impact. In Canada, the first and only isolation of SVC virus (SVCV) was in 2006, from common carp Cyprinus carpio L., at Hamilton Harbour, Lake Ontario. The susceptibility of fathead minnow Pimephales promelas Rafinesque, emerald shiner Notropis atherinoides Rafinesque and white sucker Catostomus commersonii (Lacepede) to intraperitoneal injection of the Canadian isolate (HHOcarp06) was evaluated using experimental infection, virus isolation, quantitative reverse transcription polymerase chain reaction (qRT-PCR), histopathology and immunohistochemistry (IHC). Emerald shiner and fathead minnow were most susceptible with 43 and 53% cumulative mortality, respectively, compared with koi at 33%. Quantitative RT-PCR demonstrated that koi had high viral loads throughout the experiment. At 34 days post-infection, SVCV was detected from sampled emerald shiner and white sucker in very low titre and was not detected from fathead minnow. Koi, fathead minnow and emerald shiner had gross lesions typical of SVC disease. The histopathological picture was mostly dominated by necrotic changes in kidney, spleen, liver, pancreas and intestine. IHC further confirmed SVCV infection, and staining was largely correlated with histological lesions. © 2015 John Wiley & Sons Ltd.

  10. Evaluation of a central venous catheter tip placement for superior vena cava–subclavian central venous catheterization using a premeasured length

    PubMed Central

    Kwon, Hyun-Jung; Jeong, Young-Il; Jun, In-Gu; Moon, Young-Jin; Lee, Yu-Mi

    2018-01-01

    Abstract Subclavian central venous catheterization is a common procedure for which misplacement of the central venous catheter (CVC) is a frequent complication that can potentially be fatal. The carina is located in the mid-zone of the superior vena cava (SVC) and is considered a reliable landmark for CVC placement in chest radiographs. The C-length, defined as the distance from the edge of the right transverse process of the first thoracic spine to the carina, can be measured in posteroanterior chest radiographs using a picture archiving and communication system. To evaluate the placement of the tip of the CVC in subclavian central venous catheterizations using the C-length, we reviewed the medical records and chest radiographs of 122 adult patients in whom CVC catheterization was performed (from January 2012 to December 2014) via the right subclavian vein using the C-length. The tips of all subclavian CVCs were placed in the SVC using the C-length. No subclavian CVC entered the right atrium. Tip placement was not affected by demographic characteristics such as age, sex, height, weight, and body mass index. The evidence indicates that the C-length on chest radiographs can be used to determine the available insertion length and place the right subclavian CVC tip into the SVC. PMID:29480861

  11. Network-aware scalable video monitoring system for emergency situations with operator-managed fidelity control

    NASA Astrophysics Data System (ADS)

    Al Hadhrami, Tawfik; Nightingale, James M.; Wang, Qi; Grecos, Christos

    2014-05-01

    In emergency situations, the ability to remotely monitor unfolding events using high-quality video feeds will significantly improve the incident commander's understanding of the situation and thereby aids effective decision making. This paper presents a novel, adaptive video monitoring system for emergency situations where the normal communications network infrastructure has been severely impaired or is no longer operational. The proposed scheme, operating over a rapidly deployable wireless mesh network, supports real-time video feeds between first responders, forward operating bases and primary command and control centers. Video feeds captured on portable devices carried by first responders and by static visual sensors are encoded in H.264/SVC, the scalable extension to H.264/AVC, allowing efficient, standard-based temporal, spatial, and quality scalability of the video. A three-tier video delivery system is proposed, which balances the need to avoid overuse of mesh nodes with the operational requirements of the emergency management team. In the first tier, the video feeds are delivered at a low spatial and temporal resolution employing only the base layer of the H.264/SVC video stream. Routing in this mode is designed to employ all nodes across the entire mesh network. In the second tier, whenever operational considerations require that commanders or operators focus on a particular video feed, a `fidelity control' mechanism at the monitoring station sends control messages to the routing and scheduling agents in the mesh network, which increase the quality of the received picture using SNR scalability while conserving bandwidth by maintaining a low frame rate. In this mode, routing decisions are based on reliable packet delivery with the most reliable routes being used to deliver the base and lower enhancement layers; as fidelity is increased and more scalable layers are transmitted they will be assigned to routes in descending order of reliability. The third tier of video delivery transmits a high-quality video stream including all available scalable layers using the most reliable routes through the mesh network ensuring the highest possible video quality. The proposed scheme is implemented in a proven simulator, and the performance of the proposed system is numerically evaluated through extensive simulations. We further present an in-depth analysis of the proposed solutions and potential approaches towards supporting high-quality visual communications in such a demanding context.

  12. Portable Video Media Versus Standard Verbal Communication in Surgical Information Delivery to Nurses: A Prospective Multicenter, Randomized Controlled Crossover Trial.

    PubMed

    Kam, Jonathan; Ainsworth, Hannah; Handmer, Marcus; Louie-Johnsun, Mark; Winter, Matthew

    2016-10-01

    Continuing education of health professionals is important for delivery of quality health care. Surgical nurses are often required to understand surgical procedures. Nurses need to be aware of the expected outcomes and recognize potential complications of such procedures during their daily work. Traditional educational methods, such as conferences and tutorials or informal education at the bedside, have many drawbacks for delivery of this information in a universal, standardized, and timely manner. The rapid uptake of portable media devices makes portable video media (PVM) a potential alternative to current educational methods. To compare PVM to standard verbal communication (SVC) for surgical information delivery and educational training for nurses and evaluate its impact on knowledge acquisition and participant satisfaction. Prospective, multicenter, randomized controlled crossover trial. Two hospitals: Gosford District Hospital and Wyong Hospital. Seventy-two nursing staff (36 at each site). Information delivery via PVM--7-minute video compared to information delivered via SVC. Knowledge acquisition was measured by a 32-point questionnaire, and satisfaction with the method of education delivery was measured using the validated Client Satisfaction Questionnaire (CSQ-8). Knowledge acquisition was higher via PVM compared to SVC 25.9 (95% confidence interval [CI] 25.2-26.6) versus 24.3 (95% CI 23.5-25.1), p = .004. Participant satisfaction was higher with PVM 29.5 (95% CI 28.3-30.7) versus 26.5 (95% CI 25.1-27.9), p = .003. Following information delivery via SVC, participants had a 6% increase in knowledge scores, 24.3 (95% CI 23.5-25.1) versus 25.7 (95% CI 24.9-26.5) p = .001, and a 13% increase in satisfaction scores, 26.5 (95% CI 25.1-27.9) versus 29.9 (95% CI 28.8-31.0) p < .001, when they crossed-over to information delivery via PVM. PVM provides a novel method for providing education to nurses that improves knowledge retention and satisfaction with the educational process. © 2016 Sigma Theta Tau International.

  13. SVC obstruction

    MedlinePlus

    The goal of treatment is to relieve the blockage. Diuretics (water pills) or steroids (anti-inflammtory drugs) may be used to temporarily relieve swelling . Other treatment options may include radiation or chemotherapy to shrink the tumor, or surgery to ...

  14. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  15. Outcome and management of pacemaker-induced superior vena cava syndrome.

    PubMed

    Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei

    2014-11-01

    We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.

  16. A multi-camera system for real-time pose estimation

    NASA Astrophysics Data System (ADS)

    Savakis, Andreas; Erhard, Matthew; Schimmel, James; Hnatow, Justin

    2007-04-01

    This paper presents a multi-camera system that performs face detection and pose estimation in real-time and may be used for intelligent computing within a visual sensor network for surveillance or human-computer interaction. The system consists of a Scene View Camera (SVC), which operates at a fixed zoom level, and an Object View Camera (OVC), which continuously adjusts its zoom level to match objects of interest. The SVC is set to survey the whole filed of view. Once a region has been identified by the SVC as a potential object of interest, e.g. a face, the OVC zooms in to locate specific features. In this system, face candidate regions are selected based on skin color and face detection is accomplished using a Support Vector Machine classifier. The locations of the eyes and mouth are detected inside the face region using neural network feature detectors. Pose estimation is performed based on a geometrical model, where the head is modeled as a spherical object that rotates upon the vertical axis. The triangle formed by the mouth and eyes defines a vertical plane that intersects the head sphere. By projecting the eyes-mouth triangle onto a two dimensional viewing plane, equations were obtained that describe the change in its angles as the yaw pose angle increases. These equations are then combined and used for efficient pose estimation. The system achieves real-time performance for live video input. Testing results assessing system performance are presented for both still images and video.

  17. 77 FR 4557 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    .... Applicants: Entergy Nuclear Generation Company, Entergy Nuclear Power Marketing, LLC, Entergy Nuclear Vermont... IFA and Svc Agmt with FPL Energy Green Power Wind, LLC to be effective 1/21/2012. Filed Date: 1/20/12...

  18. Comparison between Indirect Immunofluorescence Assay and Shell Vial Culture for Detection of Mumps Virus from Clinical Samples

    PubMed Central

    Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita

    2003-01-01

    We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158

  19. Complement factor H is expressed in adipose tissue in association with insulin resistance.

    PubMed

    Moreno-Navarrete, José María; Martínez-Barricarte, Rubén; Catalán, Victoria; Sabater, Mònica; Gómez-Ambrosi, Javier; Ortega, Francisco José; Ricart, Wifredo; Blüher, Mathias; Frühbeck, Gema; Rodríguez de Cordoba, Santiago; Fernández-Real, José Manuel

    2010-01-01

    Activation of the alternative pathway of the complement system, in which factor H (fH; complement fH [CFH]) is a key regulatory component, has been suggested as a link between obesity and metabolic disorders. Our objective was to study the associations between circulating and adipose tissue gene expressions of CFH and complement factor B (fB; CFB) with obesity and insulin resistance. Circulating fH and fB were determined by enzyme-linked immunosorbent assay in 398 subjects. CFH and CFB gene expressions were evaluated in 76 adipose tissue samples, in isolated adipocytes, and in stromovascular cells (SVC) (n = 13). The effects of weight loss and rosiglitazone were investigated in independent cohorts. Both circulating fH and fB were associated positively with BMI, waist circumference, triglycerides, and inflammatory parameters and negatively with insulin sensitivity and HDL cholesterol. For the first time, CFH gene expression was detected in human adipose tissue (significantly increased in subcutaneous compared with omental fat). CFH gene expression in omental fat was significantly associated with insulin resistance. In contrast, CFB gene expression was significantly increased in omental fat but also in association with fasting glucose and triglycerides. The SVC fraction was responsible for these differences, although isolated adipocytes also expressed fB and fH at low levels. Both weight loss and rosiglitazone led to significantly decreased circulating fB and fH levels. Increased circulating fH and fB concentrations in subjects with altered glucose tolerance could reflect increased SVC-induced activation of the alternative pathway of complement in omental adipose tissue linked to insulin resistance and metabolic disturbances.

  20. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less

  1. 9 CFR 93.904 - Health certificate for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... that are imported from any region of the world must be accompanied by a health certificate issued by a... viral assays by the competent authority. (3) SVC-susceptible fish populations in the region or...

  2. Comparison of Covered Versus Uncovered Stents for Benign Superior Vena Cava (SVC) Obstruction.

    PubMed

    Haddad, Mustafa M; Simmons, Benjamin; McPhail, Ian R; Kalra, Manju; Neisen, Melissa J; Johnson, Matthew P; Stockland, Andrew H; Andrews, James C; Misra, Sanjay; Bjarnason, Haraldur

    2018-05-01

    To identify whether long-term symptom relief and stent patency vary with the use of covered versus uncovered stents for the treatment of benign SVC obstruction. We retrospectively identified all patients with benign SVC syndrome treated to stent placement between January 2003 and December 2015 (n = 59). Only cases with both clinical and imaging follow-up were included (n = 47). In 33 (70%) of the patients, the obstruction was due to a central line or pacemaker wires, and in 14 (30%), the cause was fibrosing mediastinitis. Covered stents were placed in 17 (36%) of the patients, and 30 (64%) patients had an uncovered stent. Clinical and treatment outcomes, complications, and the percent stenosis of each stent were evaluated. Technical success was achieved in all cases at first attempt. Average clinical and imaging follow-up in years was 2.7 (range 0.1-11.1) (covered) and 1.7 (range 0.2-10.5) (uncovered), respectively. There was a significant difference (p = 0.044) in the number of patients who reported a return of symptoms between the covered (5/17 or 29.4%) and uncovered (18/30 or 60%) groups. There was also a significant difference (p = < 0.001) in the mean percent stenosis after stent placement between the covered [17.9% (range 0-100) ± 26.2] and uncovered [48.3% (range 6.8-100) ± 33.5] groups. No significant difference (p = 0.227) was found in the time (days) between the date of the procedure and the date of clinical follow-up where a return of symptoms was reported [covered: 426.6 (range 28-1554) ± 633.9 and uncovered 778.1 (range 23-3851) ± 1066.8]. One patient in the uncovered group had non-endovascular surgical intervention (innominate to right atrial bypass), while none in the covered group required surgical intervention. One major complication (SIR grade C) occurred that consisted of a pericardial hemorrhagic effusion after angioplasty that required covered stent placement. There were no procedure-related deaths. Both covered and uncovered stents can be used for treating benign SVC syndrome. Covered stents, however, may be a more effective option at providing symptom relief and maintaining stent patency if validated by further studies.

  3. Large thoracic tumor without superior vena cava syndrome.

    PubMed

    Garmpis, Nikolaos; Damaskos, Christos; Patelis, Nikolaos; Dimitroulis, Dimitrios; Spartalis, Eleftherios; Tomos, Ioannis; Garmpi, Anna; Spartalis, Michael; Antoniou, Efstathios A; Kontzoglou, Konstantinos; Tomos, Periklis

    2017-04-10

    A 62 year-old male with long-standing smoking history presented with hemoptysis. Plain chest x-ray showed abnormal findings proximate to the right pulmonary hilum. Bronchoscopy revealed a fragile exophytic tumor of the right wall of the lower third of the trachea, infiltrating the right main bronchus (75% stenosis) and the right upper lobar bronchus (near total occlusion). Contrast-enhanced chest CT demonstrated a 7.2x4.9 cm tumor contiguous to the above-mentioned structures, mediastinal lymph node pathology, and a vessel coursing inferiorly to the left of the aortic arch and anterior to the left hilum. Despite the tumor constricting the right superior vena cava, no signs of superior vena cava syndrome were present. In this case, the patient does not present with Superior Vena Cava (SVC) syndrome, as expected due to the constriction of the (right) SVC caused by the tumor, since head and neck veins drain through the Persistent Left Superior Vena Cava (PLSVC). PLSVC is the most common thoracic venous anomaly with an incidence of 0.3% to 0.5% of the general population and it is a congenital anomaly caused by the failure of the left anterior cardinal vein to regress and to consequently form the ligament of Marshall during fetal development. It is associated with absence of the left brachiocephalic vein and in 10 to 20% of cases the right SVC is absent. Two potential draining points of the PLSVC have been previously reported. In the majority of cases PLSVC drains directly into the coronary sinus, but less frequently it drains into the left atrium or the left superior pulmonary vein. In cases where the PLSVC drains into the coronary sinus, congenital heart defects are rare. The patient usually remains asymptomatic and PLSVC is an incidental finding during radiographic imaging or medical procedures. When the PLSVC drains into the left atrium or the left superior pulmonary vein, a right-to-left shunt is formed; a condition usually asymptomatic. In some reported cases this PLSVC variant presents with persistent, unexplained hypoxia or cyanosis and embolisation causing recurrent transient ischemic attacks and/or cerebral abscesses. This PLSVC variant is more often associated with absence of the right SVC and congenital heart abnormalities.

  4. Secular variation between 5 and 10c CE in Japan: remeasurements of 2000 samples collected between 1960-70's from Sueki earthenware kilns in Osaka.

    NASA Astrophysics Data System (ADS)

    Shibuya, H.; Mochizuki, N.; Hatakeyama, T.

    2015-12-01

    In Japan, archeomagnetic measurements are vigorously developed for years, though it is not well known to paleomagnetism community in english. One of the works is massive archeomagnetic study of Suemura kiln group carried out in Osaka University in 1960's to early 70's. More than 500 kilns were excavated in Sakai city and vicinities, Osaka Prefecture, Japan. The kiln group is called as Suemura Kilns, and are for Sueki earthenware of 5c to 10c CE. About 300 kilns were sampled and most of the samples were measured at the time, and the results are reported in e.g. Hirooka (1971) and Shibuya (1980). However, the results have significant scatter in direction, which may be due to the limitation of old astatic magnetometer measurements and handwriting graphic determination of magnetic direction, and/or the lack of demagnetization. We recently inherited many of those samples and remeasured them with spinner magnetometer applying alternation field demagnetization (afd). The magnetizations are generally very stable, as usual as other archeomagnetic samples, and afd does not change the magnetic direction mostly. However, significant number of sites show large scatter in magnetic directions, which might be due to the wrong identification of kiln floor or disturbance at the time of collapsing or excavation. Taking kilns of α95<4o, we recovered 131 paleomagnetic directions. Although third of them are dated by pottery shape chronology, the range of each pottery style is not precisely known and the relation of the baked floor and the potteries excavated around kilns are not always clear. The carbon dating of those kilns are very scares. Thus we first try to draw secular variation curve in declination-inclination plot. With the rough ages of those kilns, it is pretty easy to draw the SVC. It is also numerically determined taking the distance of each direction from nearest point in SVC and the velocity change of the SVC as penalty function, within a couple of degrees in the error. The the age of each point is assigned to satisfy the archeological ages. This precise SVC in the far east will improve understanding the geomagnetic variations, as well as application to the archeological dating.

  5. Extensions under development for the HEVC standard

    NASA Astrophysics Data System (ADS)

    Sullivan, Gary J.

    2013-09-01

    This paper discusses standardization activities for extending the capabilities of the High Efficiency Video Coding (HEVC) standard - the first edition of which was completed in early 2013. These near-term extensions are focused on three areas: range extensions (such as enhanced chroma formats, monochrome video, and increased bit depth), bitstream scalability extensions for spatial and fidelity scalability, and 3D video extensions (including stereoscopic/multi-view coding, and probably also depth map coding and combinations thereof). Standardization extensions on each of these topics will be completed by mid-2014, and further work beyond that timeframe is also discussed.

  6. Volcanic stratigraphy and geochemistry of the Soufrière Volcanic Centre, Saint Lucia with implications for volcanic hazards

    NASA Astrophysics Data System (ADS)

    Lindsay, Jan M.; Trumbull, Robert B.; Schmitt, Axel K.; Stockli, Daniel F.; Shane, Phil A.; Howe, Tracy M.

    2013-05-01

    The Soufrière Volcanic Complex (SVC), Saint Lucia, represents one of the largest silicic centres in the Lesser Antilles arc. It comprises extensive pumiceous pyroclastic flow deposits, lava flows as well as Peléan-style domes and dome collapse block-and-ash-flow deposits. These deposits occur within and around the Qualibou Depression, a ~ 10-km diameter wide sector collapse structure. To date, vent locations for SVC pyroclastic deposits and their relationship to the sector collapse have been unclear because of limited stratigraphic correlation and few radiometric ages. In this study we reconstruct the geologic history of the SVC in light of new and recently published (U-Th)/He, U-Th and U-Pb zircon chronostratigraphic data, aided by mineralogical and geochemical correlation. Compositionally, SVC deposits are monotonous medium-K, calc-alkaline rocks with 61.6 to 67.7 wt.% SiO2 and display similar trace element abundances. Combined U-Th and (U-Th)/He zircon dating together with 14C ages and mineral fingerprinting reveals significant explosive eruptions at 640, 515, 265, 104, 60 and 40 ka (producing deposits previously grouped together as the "Choiseul" unit) and at 20 ka (Belfond unit). The mineralogically and geochemically distinct Belfond unit is a large, valley-filling pumiceous pyroclastic flow deposit distributed to the north, northeast, south and southeast of the Qualibou Depression that was probably deposited during a single plinian eruption. The unit previously referred to as ‘Choiseul tuff' is much less well defined. The typical Choiseul unit comprises a series of yellowish-white, crystal-poor, non-welded pumiceous pyroclastic deposits cropping out to the north and southeast of the Qualibou depression; however its age is poorly constrained. A number of other units previously mapped as Choiseul can be distinguished based on age, and in some cases mineral and whole rock chemistry. Pyroclastic deposits at Micoud (640 ± 19 ka), Bellevue (264 ± 8 ka), Anse John (104 ± 4 ka) and La Pointe (59.8 ± 2.1 ka), Anse Noir and Piaye were all previously grouped with or associated with the Choiseul tuff (all uncertainties 1σ). We suggest that these units represent individual periods of activity spanning a range of ages, whereas Choiseul pumice at the type locality has yielded a (U-Th)/He zircon age of 515 ± 19 ka. Their overall geochemical and mineralogical similarities with the Choiseul at the type locality suggest that they might have all originated from the same centre. Morne Tabac (532 ± 21 ka) is a dome truncated by the depression escarpment, whereas Morne Bonin (273 ± 15 ka), Gros Piton and Petit Piton (71 ± 3 ka and 109 ± 4 ka, resp.), Belfond (13.6 ± 0.4 ka) and Terre Blanche (15.3 ± 0.4 ka) are domes within the Qualibou Depression. Belfond and Terre Blanche have whole rock geochemistry and mineral assemblages similar to the Belfond pyroclastic flow deposit, thus possibly representing late-erupted degassed portions of the magma that produced the Belfond pyroclastics. The geochemical characteristics and similar zircon age distributions of the silicic lava domes and pyroclastics of the SVC suggest that these share a common magma source beneath the Qualibou depression. The distribution of the pyroclastic flows and the wide range in their eruption ages makes it unlikely that these were erupted during caldera-forming activity, and we instead invoke a series of smaller-volume explosive eruptions from the area of the current depression, the earliest of which occurred from a large proto-Qualibou edifice that subsequently underwent sector collapse. Activity from this proto-Qualibou centre may have ceased sometime between 38 and 59 ka ago, it therefore seems unlikely given our present understanding that there will be another eruption from the southern central highland region. However, the young dome-forming activity in the Qualibou depression may have occurred in or close to the Holocene, and there have been dome collapse events and explosion craters formed since then. A new dome eruption or renewed activity at a dome within the depression, growing in the style of the ongoing Soufrière Hills lava dome on the nearby island of Montserrat, is possible; as is a future plinian eruption from this area. Such an eruption would not only have a devastating impact on Saint Lucia, but would also have significant regional and global impacts.

  7. Compression performance of HEVC and its format range and screen content coding extensions

    NASA Astrophysics Data System (ADS)

    Li, Bin; Xu, Jizheng; Sullivan, Gary J.

    2015-09-01

    This paper presents a comparison-based test of the objective compression performance of the High Efficiency Video Coding (HEVC) standard, its format range extensions (RExt), and its draft screen content coding extensions (SCC). The current dominant standard, H.264/MPEG-4 AVC, is used as an anchor reference in the comparison. The conditions used for the comparison tests were designed to reflect relevant application scenarios and to enable a fair comparison to the maximum extent feasible - i.e., using comparable quantization settings, reference frame buffering, intra refresh periods, rate-distortion optimization decision processing, etc. It is noted that such PSNR-based objective comparisons generally provide more conservative estimates of HEVC benefit than are found in subjective studies. The experimental results show that, when compared with H.264/MPEG-4 AVC, HEVC version 1 provides a bit rate savings for equal PSNR of about 23% for all-intra coding, 34% for random access coding, and 38% for low-delay coding. This is consistent with prior studies and the general characterization that HEVC can provide about a bit rate savings of about 50% for equal subjective quality for most applications. The HEVC format range extensions provide a similar bit rate savings of about 13-25% for all-intra coding, 28-33% for random access coding, and 32-38% for low-delay coding at different bit rate ranges. For lossy coding of screen content, the HEVC screen content coding extensions achieve a bit rate savings of about 66%, 63%, and 61% for all-intra coding, random access coding, and low-delay coding, respectively. For lossless coding, the corresponding bit rate savings are about 40%, 33%, and 32%, respectively.

  8. Complement Factor H Is Expressed in Adipose Tissue in Association With Insulin Resistance

    PubMed Central

    Moreno-Navarrete, José María; Martínez-Barricarte, Rubén; Catalán, Victoria; Sabater, Mònica; Gómez-Ambrosi, Javier; Ortega, Francisco José; Ricart, Wifredo; Blüher, Mathias; Frühbeck, Gema; Rodríguez de Cordoba, Santiago; Fernández-Real, José Manuel

    2010-01-01

    OBJECTIVE Activation of the alternative pathway of the complement system, in which factor H (fH; complement fH [CFH]) is a key regulatory component, has been suggested as a link between obesity and metabolic disorders. Our objective was to study the associations between circulating and adipose tissue gene expressions of CFH and complement factor B (fB; CFB) with obesity and insulin resistance. RESEARCH DESIGN AND METHODS Circulating fH and fB were determined by enzyme-linked immunosorbent assay in 398 subjects. CFH and CFB gene expressions were evaluated in 76 adipose tissue samples, in isolated adipocytes, and in stromovascular cells (SVC) (n = 13). The effects of weight loss and rosiglitazone were investigated in independent cohorts. RESULTS Both circulating fH and fB were associated positively with BMI, waist circumference, triglycerides, and inflammatory parameters and negatively with insulin sensitivity and HDL cholesterol. For the first time, CFH gene expression was detected in human adipose tissue (significantly increased in subcutaneous compared with omental fat). CFH gene expression in omental fat was significantly associated with insulin resistance. In contrast, CFB gene expression was significantly increased in omental fat but also in association with fasting glucose and triglycerides. The SVC fraction was responsible for these differences, although isolated adipocytes also expressed fB and fH at low levels. Both weight loss and rosiglitazone led to significantly decreased circulating fB and fH levels. CONCLUSIONS Increased circulating fH and fB concentrations in subjects with altered glucose tolerance could reflect increased SVC-induced activation of the alternative pathway of complement in omental adipose tissue linked to insulin resistance and metabolic disturbances. PMID:19833879

  9. Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation.

    PubMed

    Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A

    2015-06-01

    The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P < 0.001). Venous pressure waveforms were obtained in all patients and attenuation of the waveform was always observed prior to onset of phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  10. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach.

    PubMed

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-12-01

    To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17-73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections.

  11. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach

    PubMed Central

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-01-01

    Objective: To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. Methods: 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17–73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. Results: In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Conclusions: Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections. PMID:12433899

  12. Effects of Anxiety and Depression on Arterial Elasticity of Subjects With Suboptimal Physical Health.

    PubMed

    Sun, Ningling; Xi, Yang; Zhu, Zhiming; Yin, Huijun; Tao, Qiushan; Wang, Hongyi; Wang, Luyan; Ma, Zhiyi; Chen, Yuanyuan; Yao, Dan

    2015-10-01

    The authors investigated the effects of suboptimal health status (SHS; high-normal blood pressure, blood glucose, and blood lipids) on arterial elasticity in subjects with or without anxiety or depression. Suboptimal physical health status and anxiety or depression increase the risk of cardiovascular diseases. This was a cross-sectional, observational, multicenter study. Among 1520 subjects who underwent physical examination between May 2009 and December 2012 in Beijing and Chongqing, China, 955 were included. All subjects completed anxiety and depression questionnaires. Systemic vascular compliance (SVC), systemic vascular resistance, and brachial artery distensibility (BAD) were measured during arterial elasticity evaluation. Of 955 participants, 633 were classified as having SHS and 322 were classified as healthy. Systemic vascular compliance and BAD were worse in SHS subjects than in healthy subjects (SVC: 1.23 ± 0.22 vs 1.29 ± 0.25 mL/mm Hg; BAD: 6.26 ± 1.32 vs 6.61 ± 1.24%/mm Hg, respectively; both P < 0.05). Of 955 subjects, 37.7% and 43.9% had anxiety and depression, respectively. Systemic vascular compliance and BAD in SHS subjects with concomitant anxiety or depression were significantly lower than in SHS subjects without anxiety or depression (SVC: 1.22 ± 0.23 vs 1.23 ± 0.20 mL/mm Hg; BAD: 6.10 ± 1.36 vs 6.33 ± 1.20 %/mm Hg, respectively; both P < 0.05) and even lower than in healthy subjects. Though anxiety and depression had less impact on arterial elasticity in a healthy population, they may be involved in pathogenesis of vascular damage in the population with SHS. © 2015 Wiley Periodicals, Inc.

  13. A Method for Constructing a New Extensible Nomenclature for Clinical Coding Practices in Sub-Saharan Africa.

    PubMed

    Van Laere, Sven; Nyssen, Marc; Verbeke, Frank

    2017-01-01

    Clinical coding is a requirement to provide valuable data for billing, epidemiology and health care resource allocation. In sub-Saharan Africa, we observe a growing awareness of the need for coding of clinical data, not only in health insurances, but also in governments and the hospitals. Presently, coding systems in sub-Saharan Africa are often used for billing purposes. In this paper we consider the use of a nomenclature to also have a clinical impact. Often coding systems are assumed to be complex and too extensive to be used in daily practice. Here, we present a method for constructing a new nomenclature based on existing coding systems by considering a minimal subset in the sub-Saharan region. Evaluation of completeness will be done nationally using the requirements of national registries. The nomenclature requires an extension character for dealing with codes that have to be used for multiple registries. Hospitals will benefit most by using this extension character.

  14. Performance optimization of a hybrid micro-grid based on double-loop MPPT and SVC-MERS

    NASA Astrophysics Data System (ADS)

    Wei, Yewen; Hou, Xilun; Zhang, Xiang; Xiong, Shengnan; Peng, Fei

    2018-02-01

    With ever-increasing concerns on environmental pollution and energy shortage, the development of renewable resource has attracted a lot of attention. This paper first reviews both the wind and photovoltaic (PV) generation techniques and approaches of micro-grid voltage control. Then, a novel islanded micro-grid, which consists of wind & PV generation and hybrid-energy storage device, is built for application to remote and isolated areas. For the PV power generation branch, a double- maximum power point tracking (MPPT) technique is developed to trace the sunlight and regulate the tilt angle of PV panels. For wind-power generation branch, squirrel cage induction generator (SCIG) is used as its simple structure, robustness and less cost. In order to stabilize the output voltage of SCIGs, a new Static Var Compensator named magnetic energy recovery switch (SVC-MERS) is applied. Finally, experimental results confirm that both of the proposed methods can improve the efficiency of PV power generation and voltage stability of the micro-grid, respectively.

  15. Treatment of Superior Vena Cava (SVC) Syndrome and Inferior Vena Cava (IVC) Thrombosis in a Patient with Colorectal Cancer: Combination of SVC Stenting and IVC Filter Placement to Palliate Symptoms and Pave the Way for Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauter, Alexander; Triller, Juergen; Schmidt, Felix

    Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less

  16. Automated implantable cardioverter defibrillator lead infection in a patient with previous superior vena cava thrombosis.

    PubMed

    Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave

    2015-11-04

    We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.

  17. Subjective evaluation of H.265/HEVC based dynamic adaptive video streaming over HTTP (HEVC-DASH)

    NASA Astrophysics Data System (ADS)

    Irondi, Iheanyi; Wang, Qi; Grecos, Christos

    2015-02-01

    The Dynamic Adaptive Streaming over HTTP (DASH) standard is becoming increasingly popular for real-time adaptive HTTP streaming of internet video in response to unstable network conditions. Integration of DASH streaming techniques with the new H.265/HEVC video coding standard is a promising area of research. The performance of HEVC-DASH systems has been previously evaluated by a few researchers using objective metrics, however subjective evaluation would provide a better measure of the user's Quality of Experience (QoE) and overall performance of the system. This paper presents a subjective evaluation of an HEVC-DASH system implemented in a hardware testbed. Previous studies in this area have focused on using the current H.264/AVC (Advanced Video Coding) or H.264/SVC (Scalable Video Coding) codecs and moreover, there has been no established standard test procedure for the subjective evaluation of DASH adaptive streaming. In this paper, we define a test plan for HEVC-DASH with a carefully justified data set employing longer video sequences that would be sufficient to demonstrate the bitrate switching operations in response to various network condition patterns. We evaluate the end user's real-time QoE online by investigating the perceived impact of delay, different packet loss rates, fluctuating bandwidth, and the perceived quality of using different DASH video stream segment sizes on a video streaming session using different video sequences. The Mean Opinion Score (MOS) results give an insight into the performance of the system and expectation of the users. The results from this study show the impact of different network impairments and different video segments on users' QoE and further analysis and study may help in optimizing system performance.

  18. Breaking the Code: The Creative Use of QR Codes to Market Extension Events

    ERIC Educational Resources Information Center

    Hill, Paul; Mills, Rebecca; Peterson, GaeLynn; Smith, Janet

    2013-01-01

    The use of smartphones has drastically increased in recent years, heralding an explosion in the use of QR codes. The black and white square barcodes that link the physical and digital world are everywhere. These simple codes can provide many opportunities to connect people in the physical world with many of Extension online resources. The…

  19. Implication of Spectral Characteristic of Chlorite Based on Spectrums SWIR in Nuri Deposit of Tibet

    NASA Astrophysics Data System (ADS)

    Huang, Z.

    2017-12-01

    This contribution reports the spectral characterization of chlorite in Nuri deposit of Tibet. Nuri Cu polymetallic deposit locates in south rim of Eastern of Gangdise in Tibet. It is presented for large metallogenic scale and special mineralized combination. The study area is underlain extensively by lower Cretaceous rocks of Bima Formation, upper Cretaceous to Paleogene Danshiting Formation and the Quaternary Aeolian Sand. Intrusive bodies, which mainly are quartz diorite, granodiorite, monzonitic granitite, moyite, granite porphyry and so on, feature growth gigantic composite granitic batholith. Distribution of Chlorite is very significant for range and degree of influence of hydrothermal alteration in magmatic hydrothermal deposit. From measuring the spectral of rock and mineral using SVC portable spectrograph, it derived consequence of exists some main altered mineral chlorite. The spectra of chlorite show the absorption features at 1390, 2000, 2250, 2340nm which reflect either O-H stretching vibrations and/or Fe-OH and Mg-OH bending vibrations. Chlorite with Mg-rich shows a strong band at 2324 with a shoulder at 2245nm. The iron-rich chlorite has two absorption features which occur at 2356 and 2256nm. From 110 samples containing chlorite which measured in situ using SVC portable spectrometer, the secondary characteristic absorption wavelengths of chlorite were extracted using TSG software and the diagnosis absorption characteristic of chlorite near 2250nm wavelength is from 2232 to 2266nm. According to the absorption characteristics wavelength position near 2250nm, the samples containing chlorite divided into four categories, i.e. Mg-chlorite whose wavelength less than 2245nm, MgFe-chlorite whose wavelength between 2245 and 2250nm, FeMg-chlorite whose wavelength between 2250 and 2258nm, and Fe-chlorite whose wavelength greater than 2258nm. And then chemical composition of chlorite is analyzed by electron probe with JXA-8230 device which shows that the Fe and AlVI content of chlorite increase or Mg ion content decrease should cause the absorption wavelength of chlorite to shift to long wavelength. The result is very important meaning for mineral prospecting.

  20. 77 FR 30002 - Primary Power, LLC v. PJM Interconnection, LLC; Notice of Complaint

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-21

    ... Respondent) for the Respondent's failure to designate the Complainant to construct, own, and finance two static VAR compensator (``SVC'') projects sponsored by the Complainant that have been included in the PJM Regional Transmission Expansion Plan. The Complainant requests that the Commission grant emergency, interim...

  1. 78 FR 13760 - Proposed Collection of Information: Application Form for U.S. Department of the Treasury Stored...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... U.S. Department of the Treasury Stored Value Card (SVC) Program AGENCY: Financial Management Service, Fiscal Service, Treasury. ACTION: Notice and request for comments. SUMMARY: The Financial Management... written comments to Financial Management Service, Records and Information Management Branch, Room 135...

  2. 9 CFR 93.907-93.909 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false [Reserved] 93.907-93.909 Section 93.907-93.909 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... FOR MEANS OF CONVEYANCE AND SHIPPING CONTAINERS Aquatic Animal Species General Provisions for Svc...

  3. 9 CFR 93.907-93.909 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false [Reserved] 93.907-93.909 Section 93.907-93.909 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... FOR MEANS OF CONVEYANCE AND SHIPPING CONTAINERS Aquatic Animal Species General Provisions for Svc...

  4. NATO/CCMS Pilot Study Evaluation of Demonstrated and ...

    EPA Pesticide Factsheets

    ... "! n'nKiliHli.in Svc lln: "SiU"vlfini^ii-r^.i?i"'-ii.rhl KuiKxIi^iiii'ii P'ri'i-l,^:-. wvl|i-.|| ;IT II -:IK Ill1:l|!|i llli'lu'-l! l| tf lur '.'1 M'|XA MI,-||II'I,| H ... |-|..HAOu<- |i.| l||l \\\\Vf ...

  5. 77 FR 31642 - Hawker Beech Craft Defense Company, LLC, Also Known As Hawker Beechcraft Corporation, Also Known...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-29

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,901] Hawker Beech Craft Defense Company, LLC, Also Known As Hawker Beechcraft Corporation, Also Known As Hawker Beechcraft International SVC, Also Known As Rapid Surplus Parts, Also Known As Hawker Beechcraft Svcs, Also Known As Travel...

  6. 9 CFR 93.903 - Import permits for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Import permits for live fish... ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN ANIMAL, BIRD, AND... General Provisions for Svc-Regulated Fish Species § 93.903 Import permits for live fish, fertilized eggs...

  7. 9 CFR 93.904 - Health certificate for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Health certificate for live fish... ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN ANIMAL, BIRD, AND... General Provisions for Svc-Regulated Fish Species § 93.904 Health certificate for live fish, fertilized...

  8. 9 CFR 93.903 - Import permits for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Import permits for live fish... ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN ANIMAL, BIRD, AND... General Provisions for Svc-Regulated Fish Species § 93.903 Import permits for live fish, fertilized eggs...

  9. 9 CFR 93.903 - Import permits for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Import permits for live fish... ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN ANIMAL, BIRD, AND... General Provisions for Svc-Regulated Fish Species § 93.903 Import permits for live fish, fertilized eggs...

  10. 75 FR 62424 - EDS, an HP Company (Re-Branded as HP-Enterprise Services) Including On-Site Workers From: Abel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-08

    ... Floyd and Company, Trinity Government SYS a Private Co, Verizon Network Integration Corp, Vision... Provider Inc., Teksystems, The Experts Inc., TM Floyd and Company, Trinity Government SYS a Private Co... Compuware Corp Comsys Information Technology SVC, Diversified Systems Inc., E- Corn LLC, Farrington...

  11. 9 CFR 93.904 - Health certificate for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., fertilized eggs, and gametes. 93.904 Section 93.904 Animals and Animal Products ANIMAL AND PLANT HEALTH... eggs, and gametes. (a) General. All live fish, fertilized eggs, and gametes of SVC-susceptible species... from the date of issuance. The health certificate for the live fish, fertilized eggs, or gametes must...

  12. 9 CFR 93.906 - Inspection at the port of entry.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Inspection at the port of entry. 93.906 Section 93.906 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT...; REQUIREMENTS FOR MEANS OF CONVEYANCE AND SHIPPING CONTAINERS Aquatic Animal Species General Provisions for Svc...

  13. 9 CFR 93.906 - Inspection at the port of entry.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Inspection at the port of entry. 93.906 Section 93.906 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT...; REQUIREMENTS FOR MEANS OF CONVEYANCE AND SHIPPING CONTAINERS Aquatic Animal Species General Provisions for Svc...

  14. Exo- and endocytotic trafficking of SCAMP2.

    PubMed

    Toyooka, Kiminori; Matsuoka, Ken

    2009-12-01

    Exo- and endocytotic membrane trafficking is an essential process for transport of secretory proteins, extracellular glycans, transporters and lipids in plant cells. Using secretory carrier membrane protein 2 (SCAMP2) as a marker for secretory vesicles and tobacco BY-2 cells as a model system, we recently demonstrated that SCAMP2 positive structures containing secretory materials are transported from the Golgi apparatus to the plasma membrane (PM) and/or cell plate. This structure is consisted with clustered vesicles and was thus named the secretory vesicle cluster (SVC). Here, we have utilized the reversible photoswitching fluorescent protein Dronpa1 to trace the movement of SCAMP2 on the PM and cell plate. Activated SCAMP2-Dronpa fluorescence on the PM and cell plate moved into the BY-2 cells within several minutes, but did not spread around PM. This is consistent with recycling of SCAMP2 among endomembrane compartments such as the TGN, PM and cell plate. The relationship between SVC-mediated trafficking and exo- and endocytosis of plant cells is discussed taking into account this new data and knowledge provided by recent reports.

  15. Secure transport and adaptation of MC-EZBC video utilizing H.264-based transport protocols☆

    PubMed Central

    Hellwagner, Hermann; Hofbauer, Heinz; Kuschnig, Robert; Stütz, Thomas; Uhl, Andreas

    2012-01-01

    Universal Multimedia Access (UMA) calls for solutions where content is created once and subsequently adapted to given requirements. With regard to UMA and scalability, which is required often due to a wide variety of end clients, the best suited codecs are wavelet based (like the MC-EZBC) due to their inherent high number of scaling options. However, most transport technologies for delivering videos to end clients are targeted toward the H.264/AVC standard or, if scalability is required, the H.264/SVC. In this paper we will introduce a mapping of the MC-EZBC bitstream to existing H.264/SVC based streaming and scaling protocols. This enables the use of highly scalable wavelet based codecs on the one hand and the utilization of already existing network technologies without accruing high implementation costs on the other hand. Furthermore, we will evaluate different scaling options in order to choose the best option for given requirements. Additionally, we will evaluate different encryption options based on transport and bitstream encryption for use cases where digital rights management is required. PMID:26869746

  16. Mediastinal germ cell tumour causing superior vena cava tumour thrombosis.

    PubMed

    Karanth, Suman S; Vaid, Ashok K; Batra, Sandeep; Sharma, Devender

    2015-03-25

    We report a rare case of a 35-year-old man who presented with a 1-week history of retrosternal chest pain of moderate intensity. A positron emission tomography CT (PET-CT) showed a large fluorodeoxy-glucose (FDG)-avid heterogeneously enhancing necrotic mass in the anterosuperior mediastinum with a focal FDG-avid thrombosis of the superior vena cava (SVC) suggestive of tumour thrombus and vascular invasion. α-Fetoprotein levels were raised (5690 IU/L). Image guided biopsy of the mediastinal mass was suggestive of non-seminomatous germ cell tumour (NSGCT). The patient received four cycles of BEP (bleomycin, etoposide and cisplatin) along with therapeutic anticoagulation with low-molecular-weight heparin. Follow-up whole body PET-CT revealed complete resolution of mediastinal mass and SVC tumour thrombosis. The documentation of FDG-PET-avid tumour thrombus resolving with chemotherapy supports the concept of circulating tumour cells being important not only in common solid tumours such as breast and colon cancer but also in relatively less common tumours such as NSGCT. The detection of circulating tumour cells could help deploy aggressive regimens upfront. 2015 BMJ Publishing Group Ltd.

  17. A Novel Unsupervised Adaptive Learning Method for Long-Term Electromyography (EMG) Pattern Recognition

    PubMed Central

    Huang, Qi; Yang, Dapeng; Jiang, Li; Zhang, Huajie; Liu, Hong; Kotani, Kiyoshi

    2017-01-01

    Performance degradation will be caused by a variety of interfering factors for pattern recognition-based myoelectric control methods in the long term. This paper proposes an adaptive learning method with low computational cost to mitigate the effect in unsupervised adaptive learning scenarios. We presents a particle adaptive classifier (PAC), by constructing a particle adaptive learning strategy and universal incremental least square support vector classifier (LS-SVC). We compared PAC performance with incremental support vector classifier (ISVC) and non-adapting SVC (NSVC) in a long-term pattern recognition task in both unsupervised and supervised adaptive learning scenarios. Retraining time cost and recognition accuracy were compared by validating the classification performance on both simulated and realistic long-term EMG data. The classification results of realistic long-term EMG data showed that the PAC significantly decreased the performance degradation in unsupervised adaptive learning scenarios compared with NSVC (9.03% ± 2.23%, p < 0.05) and ISVC (13.38% ± 2.62%, p = 0.001), and reduced the retraining time cost compared with ISVC (2 ms per updating cycle vs. 50 ms per updating cycle). PMID:28608824

  18. TLBO based Voltage Stable Environment Friendly Economic Dispatch Considering Real and Reactive Power Constraints

    NASA Astrophysics Data System (ADS)

    Verma, H. K.; Mafidar, P.

    2013-09-01

    In view of growing concern towards environment, power system engineers are forced to generate quality green energy. Hence the economic dispatch (ED) aims at the power generation to meet the load demand at minimum fuel cost with environmental and voltage constraints along with essential constraints on real and reactive power. The emission control which reduces the negative impact on environment is achieved by including the additional constraints in ED problem. Presently, the power system mostly operates near its stability limits, therefore with increased demand the system faces voltage problem. The bus voltages are brought within limit in the present work by placement of static var compensator (SVC) at weak bus which is identified from bus participation factor. The optimal size of SVC is determined by univariate search method. This paper presents the use of Teaching Learning based Optimization (TLBO) algorithm for voltage stable environment friendly ED problem with real and reactive power constraints. The computational effectiveness of TLBO is established through test results over particle swarm optimization (PSO) and Big Bang-Big Crunch (BB-BC) algorithms for the ED problem.

  19. Authentication Based on Pole-zero Models of Signature Velocity

    PubMed Central

    Rashidi, Saeid; Fallah, Ali; Towhidkhah, Farzad

    2013-01-01

    With the increase of communication and financial transaction through internet, on-line signature verification is an accepted biometric technology for access control and plays a significant role in authenticity and authorization in modernized society. Therefore, fast and precise algorithms for the signature verification are very attractive. The goal of this paper is modeling of velocity signal that pattern and properties is stable for persons. With using pole-zero models based on discrete cosine transform, precise method is proposed for modeling and then features is founded from strokes. With using linear, parzen window and support vector machine classifiers, the signature verification technique was tested with a large number of authentic and forgery signatures and has demonstrated the good potential of this technique. The signatures are collected from three different database include a proprietary database, the SVC2004 and the Sabanci University signature database benchmark databases. Experimental results based on Persian, SVC2004 and SUSIG databases show that our method achieves an equal error rate of 5.91%, 5.62% and 3.91% in the skilled forgeries, respectively. PMID:24696797

  20. A Novel Unsupervised Adaptive Learning Method for Long-Term Electromyography (EMG) Pattern Recognition.

    PubMed

    Huang, Qi; Yang, Dapeng; Jiang, Li; Zhang, Huajie; Liu, Hong; Kotani, Kiyoshi

    2017-06-13

    Performance degradation will be caused by a variety of interfering factors for pattern recognition-based myoelectric control methods in the long term. This paper proposes an adaptive learning method with low computational cost to mitigate the effect in unsupervised adaptive learning scenarios. We presents a particle adaptive classifier (PAC), by constructing a particle adaptive learning strategy and universal incremental least square support vector classifier (LS-SVC). We compared PAC performance with incremental support vector classifier (ISVC) and non-adapting SVC (NSVC) in a long-term pattern recognition task in both unsupervised and supervised adaptive learning scenarios. Retraining time cost and recognition accuracy were compared by validating the classification performance on both simulated and realistic long-term EMG data. The classification results of realistic long-term EMG data showed that the PAC significantly decreased the performance degradation in unsupervised adaptive learning scenarios compared with NSVC (9.03% ± 2.23%, p < 0.05) and ISVC (13.38% ± 2.62%, p = 0.001), and reduced the retraining time cost compared with ISVC (2 ms per updating cycle vs. 50 ms per updating cycle).

  1. Application of polynomial control to design a robust oscillation-damping controller in a multimachine power system.

    PubMed

    Hasanvand, Hamed; Mozafari, Babak; Arvan, Mohammad R; Amraee, Turaj

    2015-11-01

    This paper addresses the application of a static Var compensator (SVC) to improve the damping of interarea oscillations. Optimal location and size of SVC are defined using bifurcation and modal analysis to satisfy its primary application. Furthermore, the best-input signal for damping controller is selected using Hankel singular values and right half plane-zeros. The proposed approach is aimed to design a robust PI controller based on interval plants and Kharitonov's theorem. The objective here is to determine the stability region to attain robust stability, the desired phase margin, gain margin, and bandwidth. The intersection of the resulting stability regions yields the set of kp-ki parameters. In addition, optimal multiobjective design of PI controller using particle swarm optimization (PSO) algorithm is presented. The effectiveness of the suggested controllers in damping of local and interarea oscillation modes of a multimachine power system, over a wide range of loading conditions and system configurations, is confirmed through eigenvalue analysis and nonlinear time domain simulation. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  2. New vision in fractional radiofrequency technology with switching, vacuum and cooling.

    PubMed

    Elman, Monica; Gauthier, Nelly; Belenky, Inna

    2015-04-01

    Since the introduction of fractional technology, various systems were launched to the market. The first generation of fractional RF systems created epidermal ablation with coagulative/necrosis of the dermis with sufficient clinical outcomes, but with some limitations. The aim of this study was to evaluate the efficacy and safety of SVC technology, based on the principle of separate biological responses. Fifty-two patients were treated for 3-6 sessions using fractional RF handpiece and eight patients received combination treatments with non-invasive RF handpiece. All volunteers showed notable to significant improvement in the photoageing symptoms, without any significant complications or adverse events. Due to its wide spectrum of parameters, the SVC technology can promote different biological responses. Owing to the "Switching" technology, the control of energy depth penetration enables delivery of the necessary thermal dose to the targeted skin layer. In addition, this novel technology includes the "Vacuum" and "Cooling" mechanisms, each contributing to the safety of the treatment. The Smart Heat function reduces the necessary energy levels and thereby reduces the pain level and risks for side effects.

  3. The H.264/AVC advanced video coding standard: overview and introduction to the fidelity range extensions

    NASA Astrophysics Data System (ADS)

    Sullivan, Gary J.; Topiwala, Pankaj N.; Luthra, Ajay

    2004-11-01

    H.264/MPEG-4 AVC is the latest international video coding standard. It was jointly developed by the Video Coding Experts Group (VCEG) of the ITU-T and the Moving Picture Experts Group (MPEG) of ISO/IEC. It uses state-of-the-art coding tools and provides enhanced coding efficiency for a wide range of applications, including video telephony, video conferencing, TV, storage (DVD and/or hard disk based, especially high-definition DVD), streaming video, digital video authoring, digital cinema, and many others. The work on a new set of extensions to this standard has recently been completed. These extensions, known as the Fidelity Range Extensions (FRExt), provide a number of enhanced capabilities relative to the base specification as approved in the Spring of 2003. In this paper, an overview of this standard is provided, including the highlights of the capabilities of the new FRExt features. Some comparisons with the existing MPEG-2 and MPEG-4 Part 2 standards are also provided.

  4. Message Into Medium: An Extension of the Dual Coding Hypothesis.

    ERIC Educational Resources Information Center

    Simpson, Timothy J.

    This paper examines the dual coding hypothesis, a model of the coding of visual and textual information, from the perspective of a mass media professional, such as a teacher, interested in accurately presenting both visual and textual material to a mass audience (i.e., students). It offers an extension to the theory, based upon the various skill…

  5. Video Coaching as an Efficient Teaching Method for Surgical Residents-A Randomized Controlled Trial.

    PubMed

    Soucisse, Mikael L; Boulva, Kerianne; Sideris, Lucas; Drolet, Pierre; Morin, Michel; Dubé, Pierre

    As surgical training is evolving and operative exposure is decreasing, new, effective, and experiential learning methods are needed to ensure surgical competency and patient safety. Video coaching is an emerging concept in surgery that needs further investigation. In this randomized controlled trial conducted at a single teaching hospital, participating residents were filmed performing a side-to-side intestinal anastomosis on cadaveric dog bowel for baseline assessment. The Surgical Video Coaching (SVC) group then participated in a one-on-one video playback coaching and debriefing session with a surgeon, during which constructive feedback was given. The control group went on with their normal clinical duties without coaching or debriefing. All participants were filmed making a second intestinal anastomosis. This was compared to their first anastomosis using a 7-category-validated technical skill global rating scale, the Objective Structured Assessment of Technical Skills. A single independent surgeon who did not participate in coaching or debriefing to the SVC group reviewed all videos. A satisfaction survey was then sent to the residents in the coaching group. Department of Surgery, HôpitalMaisonneuve-Rosemont, tertiary teaching hospital affiliated to the University of Montreal, Canada. General surgery residents from University of Montreal were recruited to take part in this trial. A total of 28 residents were randomized and completed the study. After intervention, the SVC group (n = 14) significantly increased their Objective Structured Assessment of Technical Skills score (mean of differences 3.36, [1.09-5.63], p = 0.007) when compared to the control group (n = 14) (mean of differences 0.29, p = 0.759). All residents agreed or strongly agreed that video coaching was a time-efficient teaching method. Video coaching is an effective and efficient teaching intervention to improve surgical residents' technical skills. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  6. Transoesophageal echocardiographic evaluation of central venous catheter positioning using Peres' formula or a radiological landmark-based approach: a prospective randomized single-centre study.

    PubMed

    Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P

    2017-02-01

    The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Endovascular stent-based revascularization of malignant superior vena cava syndrome with concomitant implantation of a port device using a dual venous approach.

    PubMed

    Anton, Susanne; Oechtering, T; Stahlberg, E; Jacob, F; Kleemann, M; Barkhausen, J; Goltz, J P

    2018-06-01

    The aim of this paper is to evaluate the safety and efficacy of endovascular revascularization of malignant superior vena cava syndrome (SVCS) and simultaneous implantation of a totally implantable venous access port (TIVAP) using a dual venous approach. Retrospectively, 31 patients (mean age 67 ± 8 years) with malignant CVO who had undergone revascularization by implantation of a self-expanding stent into the superior vena cava (SVC) (Sinus XL®, OptiMed, Germany; n = 11 [Group1] and Protégé ™ EverFlex, Covidien, Ireland; n = 20 [Group 2]) via a transfemoral access were identified. Simultaneously, percutaneous access via a subclavian vein was used to (a) probe the lesion from above, (b) facilitate a through-and-through maneuver, and (c) implant a TIVAP. Primary endpoints with regard to the SVC syndrome were technical (residual stenosis < 30%) and clinical (relief of symptoms) success; with regard to TIVAP implantation technical success was defined as positioning of the functional catheter within the SVC. Secondary endpoints were complications as well as stent and TIVAP patency. Technical and clinical success rate were 100% for revascularization of the SVS and 100% for implantation of the TIVAP. One access site hematoma (minor complication, day 2) and one port-catheter-associated sepsis (major complication, day 18) were identified. Mean catheter days were 313 ± 370 days. Mean imaging follow-up was 184 ± 172 days. Estimated patency rates at 3, 6, and 12 months were 100% in Group 1 and 84, 84, and 56% in Group 2 (p = 0.338). Stent-based revascularization of malignant SVCS with concomitant implantation of a port device using a dual venous approach appears to be safe and effective.

  8. Additional extensions to the NASCAP computer code, volume 1

    NASA Technical Reports Server (NTRS)

    Mandell, M. J.; Katz, I.; Stannard, P. R.

    1981-01-01

    Extensions and revisions to a computer code that comprehensively analyzes problems of spacecraft charging (NASCAP) are documented. Using a fully three dimensional approach, it can accurately predict spacecraft potentials under a variety of conditions. Among the extensions are a multiple electron/ion gun test tank capability, and the ability to model anisotropic and time dependent space environments. Also documented are a greatly extended MATCHG program and the preliminary version of NASCAP/LEO. The interactive MATCHG code was developed into an extremely powerful tool for the study of material-environment interactions. The NASCAP/LEO, a three dimensional code to study current collection under conditions of high voltages and short Debye lengths, was distributed for preliminary testing.

  9. Minerva: Cylindrical coordinate extension for Athena

    NASA Astrophysics Data System (ADS)

    Skinner, M. Aaron; Ostriker, Eve C.

    2013-02-01

    Minerva is a cylindrical coordinate extension of the Athena astrophysical MHD code of Stone, Gardiner, Teuben, and Hawley. The extension follows the approach of Athena's original developers and has been designed to alter the existing Cartesian-coordinates code as minimally and transparently as possible. The numerical equations in cylindrical coordinates are formulated to maintain consistency with constrained transport (CT), a central feature of the Athena algorithm, while making use of previously implemented code modules such as the Riemann solvers. Angular momentum transport, which is critical in astrophysical disk systems dominated by rotation, is treated carefully.

  10. 9 CFR 93.902 - Ports designated for the importation of live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... of live fish, fertilized eggs, and gametes. 93.902 Section 93.902 Animals and Animal Products ANIMAL... importation of live fish, fertilized eggs, and gametes. (a) The following ports are designated as ports of entry for live fish, fertilized eggs, and gametes of SVC-susceptible species imported under this subpart...

  11. Alterations in Upper Extremity Motor Function in Soldiers during Acute High Altitude Exposure,

    DTIC Science & Technology

    1988-03-01

    sensitive or controversial items. a°. Encl ALLEN CYMERIAN, Ph.D. c, ARD . SGRD-UEZ ( ) - THRU Chief, Admin Svc Br FROM Commander DATE A p odk CMT 2 TO ak 2...Function orientation and familiarization with all the tests and procedures. Prior to actual sea-level collections , each subject underwent two UEMA

  12. 9 CFR 93.902 - Ports designated for the importation of live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of live fish, fertilized eggs, and gametes. 93.902 Section 93.902 Animals and Animal Products ANIMAL... (INCLUDING POULTRY) AND ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN... Animal Species General Provisions for Svc-Regulated Fish Species § 93.902 Ports designated for the...

  13. 9 CFR 93.902 - Ports designated for the importation of live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of live fish, fertilized eggs, and gametes. 93.902 Section 93.902 Animals and Animal Products ANIMAL... (INCLUDING POULTRY) AND ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN... Animal Species General Provisions for Svc-Regulated Fish Species § 93.902 Ports designated for the...

  14. 9 CFR 93.902 - Ports designated for the importation of live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of live fish, fertilized eggs, and gametes. 93.902 Section 93.902 Animals and Animal Products ANIMAL... (INCLUDING POULTRY) AND ANIMAL PRODUCTS IMPORTATION OF CERTAIN ANIMALS, BIRDS, FISH, AND POULTRY, AND CERTAIN... Animal Species General Provisions for Svc-Regulated Fish Species § 93.902 Ports designated for the...

  15. 9 CFR 93.902 - Ports designated for the importation of live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of live fish, fertilized eggs, and gametes. 93.902 Section 93.902 Animals and Animal Products ANIMAL... importation of live fish, fertilized eggs, and gametes. (a) The following ports are designated as ports of entry for live fish, fertilized eggs, and gametes of SVC-susceptible species imported under this subpart...

  16. Spring viremia of carp

    USGS Publications Warehouse

    Ahne, W.; Bjorklund, H.V.; Essbauer, S.; Fijan, N.; Kurath, G.; Winton, J.R.

    2002-01-01

    pring viremia of carp (SVC) is an important disease affecting cyprinids, mainly common carp Cyprinus carpio. The disease is widespread in European carp culture, where it causes significant morbidity and mortality. Designated a notifiable disease by the Office International des Epizooties, SVC is caused by a rhabdovirus, spring viremia of carp virus (SVCV). Affected fish show destruction of tissues in the kidney, spleen and liver, leading to hemorrhage, loss of water-salt balance and impairment of immune response. High mortality occurs at water temperatures of 10 to 17°C, typically in spring. At higher temperatures, infected carp develop humoral antibodies that can neutralize the spread of virus and such carp are protected against re-infection by solid immunity. The virus is shed mostly with the feces and urine of clinically infected fish and by carriers. Waterborne transmission is believed to be the primary route of infection, but bloodsucking parasites like leeches and the carp louse may serve as mechanical vectors of SVCV. The genome of SVCV is composed of a single molecule of linear, negative-sense, single-stranded RNA containing 5 genes in the order 3¹-NPMGL-5¹ coding for the viral nucleoprotein, phosphoprotein, matrix protein, glycoprotein, and polymerase, respectively. Polyacrylamide gel electrophoresis of the viral proteins, and sequence homologies between the genes and gene junctions of SVCV and vesicular stomatitis viruses, have led to the placement of the virus as a tentative member of the genus Vesiculovirus in the family Rhabdoviridae. These methods also revealed that SVCV is not related to fish rhabdoviruses of the genus Novirhabdovirus. In vitro replication of SVCV takes place in the cytoplasm of cultured cells of fish, bird and mammalian origin at temperatures of 4 to 31°C, with an optimum of about 20°C. Spring viremia of carp can be diagnosed by clinical signs, isolation of virus in cell culture and molecular methods. Antibodies directed against SVCV react with the homologous virus in serum neutralization, immunofluorescence, immunoperoxidase, or enzyme-linked immunosorbent assays, but they cross-react to various degrees with the pike fry rhabdovirus (PFR), suggesting the 2 viruses are closely related. However, SVCV and PFR can be distinguished by certain serological tests and molecular methods such as the ribonuclease protection assay.

  17. Extension, validation and application of the NASCAP code

    NASA Technical Reports Server (NTRS)

    Katz, I.; Cassidy, J. J., III; Mandell, M. J.; Schnuelle, G. W.; Steen, P. G.; Parks, D. E.; Rotenberg, M.; Alexander, J. H.

    1979-01-01

    Numerous extensions were made in the NASCAP code. They fall into three categories: a greater range of definable objects, a more sophisticated computational model, and simplified code structure and usage. An important validation of NASCAP was performed using a new two dimensional computer code (TWOD). An interactive code (MATCHG) was written to compare material parameter inputs with charging results. The first major application of NASCAP was performed on the SCATHA satellite. Shadowing and charging calculation were completed. NASCAP was installed at the Air Force Geophysics Laboratory, where researchers plan to use it to interpret SCATHA data.

  18. Verification testing of the compression performance of the HEVC screen content coding extensions

    NASA Astrophysics Data System (ADS)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  19. Clinical Investigation Program Annual Progress Report.

    DTIC Science & Technology

    1985-09-30

    027 78/114 In Vitro Effect of Minoxidil on Collagen Produc- tion by Normal and Scleroderma Fibroblasts (C) (PR...effect of minoxidil on collagen production Dy normal and scleroderma fibroblasts. Previously titled: The use of minoxidil in treating progressive...Svc: (tO) Assoc Investigators: (11) Key Words: scleroderma, minoxidil Thomas P. O’Barr PhD, DAC fibroblasts, collagen Ellen Swanson MS, DAC Don

  20. 76 FR 53162 - Acceptance of Public Submissions Regarding the Study of Stable Value Contracts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-25

    ... the risk of a run on a SVF? To the extent that SVC providers use value-at-risk (``VaR'') models, do such VaR models adequately assess the risk of loss resulting from such events or other possible but extremely unlikely events? Do other loss models more adequately assess the risk of loss, such as the...

  1. 9 CFR 93.905 - Declaration and other documents for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Animal Species General Provisions for Svc-Regulated Fish Species § 93.905 Declaration and other documents... entry, the name and address of the importer, the name and address of the broker, the origin of the live fish, fertilized eggs, or gametes, the number, species, and the purpose of the importation, the name of...

  2. 9 CFR 93.905 - Declaration and other documents for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Animal Species General Provisions for Svc-Regulated Fish Species § 93.905 Declaration and other documents... entry, the name and address of the importer, the name and address of the broker, the origin of the live fish, fertilized eggs, or gametes, the number, species, and the purpose of the importation, the name of...

  3. 9 CFR 93.905 - Declaration and other documents for live fish, fertilized eggs, and gametes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Animal Species General Provisions for Svc-Regulated Fish Species § 93.905 Declaration and other documents... entry, the name and address of the importer, the name and address of the broker, the origin of the live fish, fertilized eggs, or gametes, the number, species, and the purpose of the importation, the name of...

  4. Tele-Proximity: Tele-Community of Inquiry Model. Facial Cues for Social, Cognitive, and Teacher Presence in Distance Education

    ERIC Educational Resources Information Center

    Themeli, Chryssa; Bougia, Anna

    2016-01-01

    Distance education is expanding in all continents, and the use of video has dominated internet. Synchronous Video Communication (SVC) has not been an option thoroughly investigated and practitioners, who use and design synchronous learning scenarios, are in urgent need of guidance. Distant learners face many barriers, and as a result, they drop…

  5. Changing Our Selves, Our Schools, and Our School System: Students Take on the New York City Quality Review Process

    ERIC Educational Resources Information Center

    Parkham, Shamika; McBroom, Aravis

    2015-01-01

    In this chapter, two student members of the Student Voice Collaborative (SVC) describe their experiences as "Student Shadows" during the annual Quality Review process, used throughout the New York Department of Education to evaluate how well schools are organized to support student achievement. They chronicle how this experience enhanced…

  6. Spatial and spectral analysis of corneal epithelium injury using hyperspectral images

    NASA Astrophysics Data System (ADS)

    Md Noor, Siti Salwa; Michael, Kaleena; Marshall, Stephen; Ren, Jinchang

    2017-12-01

    Eye assessment is essential in preventing blindness. Currently, the existing methods to assess corneal epithelium injury are complex and require expert knowledge. Hence, we have introduced a non-invasive technique using hyperspectral imaging (HSI) and an image analysis algorithm of corneal epithelium injury. Three groups of images were compared and analyzed, namely healthy eyes, injured eyes, and injured eyes with stain. Dimensionality reduction using principal component analysis (PCA) was applied to reduce massive data and redundancies. The first 10 principal components (PCs) were selected for further processing. The mean vector of 10 PCs with 45 pairs of all combinations was computed and sent to two classifiers. A quadratic Bayes normal classifier (QDC) and a support vector classifier (SVC) were used in this study to discriminate the eleven eyes into three groups. As a result, the combined classifier of QDC and SVC showed optimal performance with 2D PCA features (2DPCA-QDSVC) and was utilized to classify normal and abnormal tissues, using color image segmentation. The result was compared with human segmentation. The outcome showed that the proposed algorithm produced extremely promising results to assist the clinician in quantifying a cornea injury.

  7. Scalable Heuristics for Planning, Placement and Sizing of Flexible AC Transmission System Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frolov, Vladmir; Backhaus, Scott N.; Chertkov, Michael

    Aiming to relieve transmission grid congestion and improve or extend feasibility domain of the operations, we build optimization heuristics, generalizing standard AC Optimal Power Flow (OPF), for placement and sizing of Flexible Alternating Current Transmission System (FACTS) devices of the Series Compensation (SC) and Static VAR Compensation (SVC) type. One use of these devices is in resolving the case when the AC OPF solution does not exist because of congestion. Another application is developing a long-term investment strategy for placement and sizing of the SC and SVC devices to reduce operational cost and improve power system operation. SC and SVCmore » devices are represented by modification of the transmission line inductances and reactive power nodal corrections respectively. We find one placement and sizing of FACTs devices for multiple scenarios and optimal settings for each scenario simultaneously. Our solution of the nonlinear and nonconvex generalized AC-OPF consists of building a convergent sequence of convex optimizations containing only linear constraints and shows good computational scaling to larger systems. The approach is illustrated on single- and multi-scenario examples of the Matpower case-30 model.« less

  8. Spatial-Temporal Synchrophasor Data Characterization and Analytics in Smart Grid Fault Detection, Identification, and Impact Causal Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Huaiguang; Dai, Xiaoxiao; Gao, David Wenzhong

    An approach of big data characterization for smart grids (SGs) and its applications in fault detection, identification, and causal impact analysis is proposed in this paper, which aims to provide substantial data volume reduction while keeping comprehensive information from synchrophasor measurements in spatial and temporal domains. Especially, based on secondary voltage control (SVC) and local SG observation algorithm, a two-layer dynamic optimal synchrophasor measurement devices selection algorithm (OSMDSA) is proposed to determine SVC zones, their corresponding pilot buses, and the optimal synchrophasor measurement devices. Combining the two-layer dynamic OSMDSA and matching pursuit decomposition, the synchrophasor data is completely characterized inmore » the spatial-temporal domain. To demonstrate the effectiveness of the proposed characterization approach, SG situational awareness is investigated based on hidden Markov model based fault detection and identification using the spatial-temporal characteristics generated from the reduced data. To identify the major impact buses, the weighted Granger causality for SGs is proposed to investigate the causal relationship of buses during system disturbance. The IEEE 39-bus system and IEEE 118-bus system are employed to validate and evaluate the proposed approach.« less

  9. A simple method to accurately position Port-A-Cath without the aid of intraoperative fluoroscopy or other localizing devices.

    PubMed

    Horng, Huann-Cheng; Yuan, Chiou-Chung; Chao, Kuan-Chong; Cheng, Ming-Huei; Wang, Peng-Hui

    2007-06-01

    To evaluate the efficacy and acceptability of the Port-A-Cath (PAC) insertion method with (conventional group as II) and without (modified group as I) the aid of intraoperative fluoroscopy or other localizing devices. A total of 158 women with various kinds of gynecological cancers warranting PAC insertion (n = 86 in group I and n = 72 in group II, respectively) were evaluated. Data for analyses included patient age, main disease, dislocation site, surgical time, complications, and catheter outcome. There was no statistical difference between the two groups in terms of age, main disease, complications, and the experiencing of patent catheters. However, appropriate positioning (100% in group I, and 82% in group II) in the superior vena cava (SVC) showed statistical differences between the two groups (P = 0.001). In addition, the surgical time in group I was statistically shorter than that in group II (P < 0.001). The modified method for inserting the PAC offered the following benefits: including avoiding X-ray exposure for both the operator and the patient, defining the appropriate position in the SVC, and less surgical time. (c) 2007 Wiley-Liss, Inc.

  10. Initial applications of the non-Maxwellian extension of the full-wave TORIC v.5 code in the mid/high harmonic and minority heating regimes

    NASA Astrophysics Data System (ADS)

    Bertelli, N.; Valeo, E. J.; Phillips, C. K.

    2015-11-01

    A non Maxwellian extension of the full wave TORIC v.5 code in the mid/high harmonic and minority heating regimes has been revisited. In both regimes the treatment of the non-Maxwellian ions is needed in order to improve the analysis of combined fast wave (FW) and neutral beam injection (NBI) heated discharges in the current fusion devices. Additionally, this extension is also needed in time-dependent analysis where the combined heating experiments are generally considered. Initial numerical cases with thermal ions and with a non-Maxwellian ions are presented for both regimes. The simulations are then compared with results from the AORSA code, which has already been extended to include non-Maxwellian ions. First attempts to apply this extension in a self-consistent way with the NUBEAM module, which is included in the TRANSP code, are also discussed. Work supported by US DOE Contracts # DE-FC02-01ER54648 and DE-AC02-09CH11466.

  11. Management of end-stage central venous access in children referred for possible small bowel transplantation.

    PubMed

    Rodrigues, A F; van Mourik, I D M; Sharif, K; Barron, D J; de Giovanni, J V; Bennett, J; Bromley, P; Protheroe, S; John, P; de Ville de Goyet, J; Beath, S V

    2006-04-01

    The 3-year survival after small bowel transplantation (SBTx) has improved to between 73% and 88%. Impaired venous access for parenteral nutrition can be an indication for SBTx in children with chronic intestinal failure. To report our experience in management of children with extreme end-stage venous access. The study consisted of 6 children (all boys), median age of assessment 27 months (range, 13-52 months), diagnosed with total intestinal aganglionosis (1), protracted diarrhea (1), and short bowel syndrome (4), of which gastroschisis (2) and malrotation with midgut volvulus (2) were the causes. All had a documented history of more than 10 central venous catheter insertions previously. All had venograms, and 1 child additionally had a magnetic resonance angiogram to evaluate venous access. Five of 6 presented with thrombosis of the superior vena cava (SVC) and/or inferior vena cava. Venous access was reestablished as follows: transhepatic venous catheters (5), direct intra-atrial catheter via midline sternotomy (4), azygous venous catheters (2), dilatation of left subclavian vein after passage of a guide wire and then placing a catheter to reach the right atrium (1), radiological recanalization of the SVC and placement of a central venous catheter in situ (1), and direct puncture of SVC stump(1). Complications included serous pleural effusion after direct intra-atrial line insertion, which resolved after chest drain insertion (1), displacement of transhepatic catheter needing repositioning (2), and SVC stent narrowing requiring repeated balloon dilatation. Four children with permanent intestinal failure on assessment were offered SBTx, 3 of which were transplanted and were established on full enteral nutrition; the family of 1 child declined the procedure. In the remaining 2 children in whom bowel adaptation was still a possibility, attempts were made to provide adequate central venous access as feeds and drug manipulations were undertaken. One of them received liver and SBTx nearly 3 years after presenting with end-stage central venous access, because attempts to achieve independence from parenteral nutrition had failed. The other child died immediately after a transhepatic venous catheter placement, possibly from a nutritional depletion syndrome as no physical cause of death was found. Direct intra-atrial catheters in transplanted children proved to be adequate for the management of uncomplicated transplantation, although the usual infusion protocol had to be modified considerably, and the lack of access would have been critical if massive blood transfusion had been required during the transplant procedure. It was possible to reestablish central venous access in all cases. However, this was time consuming and difficult to assemble a skilled team consisting of one of more: surgeon, cardiologist, interventional radiologist, and transplant anesthetist. Small bowel transplantation is easier and safer with adequate central venous access, and we advocate liaison with an SBTx center at an early stage.

  12. A progressive data compression scheme based upon adaptive transform coding: Mixture block coding of natural images

    NASA Technical Reports Server (NTRS)

    Rost, Martin C.; Sayood, Khalid

    1991-01-01

    A method for efficiently coding natural images using a vector-quantized variable-blocksized transform source coder is presented. The method, mixture block coding (MBC), incorporates variable-rate coding by using a mixture of discrete cosine transform (DCT) source coders. Which coders are selected to code any given image region is made through a threshold driven distortion criterion. In this paper, MBC is used in two different applications. The base method is concerned with single-pass low-rate image data compression. The second is a natural extension of the base method which allows for low-rate progressive transmission (PT). Since the base method adapts easily to progressive coding, it offers the aesthetic advantage of progressive coding without incorporating extensive channel overhead. Image compression rates of approximately 0.5 bit/pel are demonstrated for both monochrome and color images.

  13. GLSENS: A Generalized Extension of LSENS Including Global Reactions and Added Sensitivity Analysis for the Perfectly Stirred Reactor

    NASA Technical Reports Server (NTRS)

    Bittker, David A.

    1996-01-01

    A generalized version of the NASA Lewis general kinetics code, LSENS, is described. The new code allows the use of global reactions as well as molecular processes in a chemical mechanism. The code also incorporates the capability of performing sensitivity analysis calculations for a perfectly stirred reactor rapidly and conveniently at the same time that the main kinetics calculations are being done. The GLSENS code has been extensively tested and has been found to be accurate and efficient. Nine example problems are presented and complete user instructions are given for the new capabilities. This report is to be used in conjunction with the documentation for the original LSENS code.

  14. Annual Research Progress Report. Fiscal Year 1989. Volume 2

    DTIC Science & Technology

    1989-10-01

    Date : 4 --- ---- Date of Periodic Review - -- Results Objective(s): i) Develop a conscious, tethered or lightly sedated , nonhuman primate model...Approach: All animal studies will be conducted at Incarnate Word College Division of Nursing and the Sciences. All procedures will be done as outlined...Gary Zarr, LTC, AN Academy of Health Sciences Dept/Svc Associate Investigators: Dpartment of Nursing Jeff Serogrham, LTC, AN Key Words: Accumulative

  15. CMMI for Services (SVC): The Strategic Landscape for Service

    DTIC Science & Technology

    2012-01-01

    processes. • Many existing models are designed for specific services or industries . • Other existing models do not provide a clear improvement path...Production, such as engineering and manufacturing Disciplines and industries , such as education, health care, insurance, utilities, and hospitality...as a Service ―More and more major businesses and industries are being run on software and delivered as online services—from movies to agriculture

  16. Clinical Investigation Program Report.

    DTIC Science & Technology

    1983-10-01

    metastatic to liver. (0) H-83-63. Double-blind, randomized parallel comparison of two different dosage regimens of naproxen sodium in patients with...different dosage regimens of naproxen sodium in patients with bone pain due to m etastatic cancer. Start Date: May 83 Est Comp Date: Indefinite Principal...Investigator: Facility: LTC D Gandara, MD LAMC CPT R Mansour, MD D ept/Svc: Associate Investigators: Hematology-Oncology Key Words: naproxen sodium

  17. Bilateral Breast Enlargement: An Unusual Presentation of Superior Vena Cava Obstruction in a Hemodialysis Patient with Fibrosing Mediastinitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goo, Dong Erk, E-mail: degoo@hosp.sch.ac.kr; Kim, Yong Jae; Choi, Deuk Lin

    2011-02-15

    A 67-year-old woman with end-stage renal disease presented with profound edema of both breasts. The presence of a patent hemodialysis basilic transposition fistula and superior vena cava obstruction (SVC), due to fibrosing mediastinitis, was demonstrated by the use of fistulography. Endovascular treatment with a balloon and stent caused immediate resolution of the breast edema.

  18. Optimizing 18F-FDG PET/CT Imaging of Vessel Wall Inflammation –The Impact of 18F-FDG Circulation Time, Injected Dose, Uptake Parameters, and Fasting Blood Glucose Levels

    PubMed Central

    Bucerius, Jan; Mani, Venkatesh; Moncrieff, Colin; Machac, Josef; Fuster, Valentin; Farkouh, Michael E.; Tawakol, Ahmed; Rudd, James H. F.; Fayad, Zahi A.

    2014-01-01

    Purpose 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is increasingly used for imaging of vessel wall inflammation. However, limited data is available regarding the impact of methodological variables, i. e. patient’s pre-scan fasting glucose, the FDG circulation time, the injected FDG dose, and of different FDG uptake parameters, in vascular FDG-PET imaging. Methods 195 patients underwent vascular FDG-PET/CT of the aorta and the carotids. Arterial standard uptake values (meanSUVmax) as well as target-to-background-ratios (meanTBRmax) and the FDG blood pool activity in the superior vein cava (SVC) and the jugular veins (JV) were quantified. Vascular FDG uptake classified according to tertiles of patient’s pre-scan fasting glucose levels, the FDG circulation time, and the injected FDG dose was compared using ANOVA. Multivariate regression analyses were performed to identify the potential impact of all variables described on the arterial and blood pool FDG uptake. Results Tertile analyses revealed FDG circulation times of about 2.5 h and prescan glucose levels of less than 7.0 mmol/l showing favorable relations between the arterial and blood pool FDG uptake. FDG circulation times showed negative associations with the aortic meanSUVmax values as well as SVC- and JV FDG blood pool activity but a positive correlation with the aortic- and carotid meanTBRmax values. Pre-scan glucose was negatively associated with aortic- and carotid meanTBRmax and carotid meanSUVmax values, but correlated positively with the SVC blood pool uptake. Injected FDG dose failed to show any significant association with the vascular FDG uptake. Conclusion FDG circulation times and pre-scan blood glucose levels significantly impact FDG uptake within the aortic and carotid wall and may bias the results of image interpretation in patients undergoing vascular FDG-PET/CT. FDG dose injected was less critical. Therefore, circulation times of about 2.5 h and pre-scan glucose levels less than 7.0 mmol/l should be preferred in this setting. PMID:24271038

  19. Short-Term Effect of Autogenic Drainage on Ventilation Inhomogeneity in Adult Subjects With Stable Non-Cystic Fibrosis Bronchiectasis.

    PubMed

    Poncin, William; Reychler, Grégory; Leeuwerck, Noémie; Bauwens, Nathalie; Aubriot, Anne-Sophie; Nader, Candice; Liistro, Giuseppe; Gohy, Sophie

    2017-05-01

    Lung clearance index (LCI), a measure of ventilation inhomogeneity derived from a multiple-breath washout test, is a promising tool for assessing airway function in patients with non-cystic fibrosis bronchiectasis. However, it is unknown whether ventilation inhomogeneity could improve after successful elimination of excessive secretions within bronchiectasis. The objective of this work was to assess the short-term effects of lung secretion clearance using the autogenic drainage technique on standard lung function tests and LCI in subjects with non-cystic fibrosis bronchiectasis. Nitrogen-based multiple-breath washout, spirometry, and body plethysmography tests were performed 30 min before autogenic drainage in adults with stable non-cystic fibrosis bronchiectasis. The autogenic drainage session was followed by a 5-min break, after which the tests were repeated in the same order. Sputum expectorated during autogenic drainage was quantified as dry weight and correlated with change between post- and pre-measurements (Δ). Paired t test or Wilcoxon signed-rank tests were used to compare pre- and post-autogenic drainage measurement outcomes. A P value of ≤.05 was considered as statistically significant. Twenty-four subjects were studied (18 females, median age [range]: 65 [21-81] y). Mean ± SD LCI significantly improved after autogenic drainage (10.88 ± 2.62 vs 10.53 ± 2.35, P = .042). However, only 20% of subjects with mucus hyperproduction during autogenic drainage had a ΔLCI that exceeded measurement variability. The percent of predicted slow vital capacity (SVC%) also slightly improved (88.7 ± 19.3% vs 90 ± 19.1%, P = .02). ΔLCI was inversely related to dry sputum weight (r = -.48, P = .02) and ΔSVC% (r = -.64, P = .001). ΔSVC% also correlated with dry sputum weight (r = 0.46, P = .02). In adults with non-cystic fibrosis bronchiectasis and mucus hypersecretion, autogenic drainage improved ventilation inhomogeneity. LCI change may be the result of the maximum recruited lung volume and the amount of cleared mucus secretion. (ClinicalTrials.gov registration NCT02411981.). Copyright © 2017 by Daedalus Enterprises.

  20. Extensions and improvements on XTRAN3S

    NASA Technical Reports Server (NTRS)

    Borland, C. J.

    1989-01-01

    Improvements to the XTRAN3S computer program are summarized. Work on this code, for steady and unsteady aerodynamic and aeroelastic analysis in the transonic flow regime has concentrated on the following areas: (1) Maintenance of the XTRAN3S code, including correction of errors, enhancement of operational capability, and installation on the Cray X-MP system; (2) Extension of the vectorization concepts in XTRAN3S to include additional areas of the code for improved execution speed; (3) Modification of the XTRAN3S algorithm for improved numerical stability for swept, tapered wing cases and improved computational efficiency; and (4) Extension of the wing-only version of XTRAN3S to include pylon and nacelle or external store capability.

  1. Single Center Experience with the AngioVac Aspiration System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salsamendi, Jason, E-mail: jsalsamendi@med.miami.edu; Doshi, Mehul, E-mail: mdoshi@med.miami.edu; Bhatia, Shivank, E-mail: sbhatia1@med.miami.edu

    2015-08-15

    PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and themore » patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.« less

  2. 78 FR 5244 - Proposed Collection; Comment Request for Regulation Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-24

    ...: REG-106511-00. Abstract: Section 6075(a) of the Internal Revenue Code (the Code) requires the executor...; however, except in the case of executors who are abroad, no such extension may be for more than 6 months. Executors currently request an extension of time to file Form 706 by filing Form 4768, ``Application for...

  3. Nassi-Schneiderman Diagram in HTML Based on AML

    ERIC Educational Resources Information Center

    Menyhárt, László

    2013-01-01

    In an earlier work I defined an extension of XML called Algorithm Markup Language (AML) for easy and understandable coding in an IDE which supports XML editing (e.g. NetBeans). The AML extension contains annotations and native language (English or Hungarian) tag names used when coding our algorithm. This paper presents a drawing tool with which…

  4. Marine Search, Rescue and Emergency Preparedness Study.

    DTIC Science & Technology

    1975-09-01

    Stampede, Boca, and Prosser Creek Reservoirs:) U. S. Forest Svc - Troy Kurth, Recreation Officer ,, erville District, Clair Engle and Lewiston Reservoirs: U...COE - Olin M. Taylor, Jr., Resource Mgr. IDAHO Central Snake Projects Office: B/R - Robert J. Brown, Superintendent INDIAN Carlyle Lake: COE - Wayne L...department U/W: U. S. Coast Guard HOSPITAL Tahoe Forest Hosp., Truckee 587-3541 (18 mi.) WEAVERVILLE DISTRICT, CLAIR ENGLE AND LEWISTON RESERVOIRS U.S

  5. 2015 QuickCompass of Sexual Assault Prevention and Response-Related Responders (QSAPR): Tabulation of Responses

    DTIC Science & Technology

    2016-03-17

    protective order (CPO)? ......................................... 66  j.  Making a Special Victims’ Counsel/Victims’ Legal Counsel (SVC/ VLC ) available...Related Responders DMDC vii i.  Special Victims’ Counsels/Victims’ Legal Counsels (SVCs/ VLCs ) ........ 81  j.  Healthcare providers...often have you faced the following barriers or challenges in implementing the elements of the DoD Sexual Assault Prevention Strategy

  6. Distributed Common Ground System-Navy Increment 2 (DCGS-N Inc 2)

    DTIC Science & Technology

    2016-03-01

    15 minutes Enter and be Managed in the Network: Reference SvcV-7, Consolidated Afloat Networks and Enterprise Services ( CANES ) CDD, DCGS-N Inc 2...Red, White , Gray Data and Tracks to Command and Control System. Continuous Stream from SCI Common Intelligence Picture to General Service (GENSER...AIS - Automatic Information System AOC - Air Operations Command CANES - Consolidated Afloat Networks and Enterprise Services CID - Center for

  7. Ballistic Testing of Australian Bisalloy Steel for Armor Applications

    DTIC Science & Technology

    2007-06-01

    CLASSIFICATION OF: 19a. NAME OF RESPONSIBLE PERSON Dwight D. Showalter a . REPORT UNCLASSIFIED b. ABSTRACT UNCLASSIFIED c . THIS PAGE UNCLASSIFIED 17...WASHINGTON PA 15301 A ND 2 SOUTHWEST RSCH INST C ANDERSON J WALKER 6220 CULEB SAN ANTONIO TX 7 DEPT OF APPL MECH & SVC R011 S NEMAT...Ballistic Testing of Australian Bisalloy Steel for Armor Applications by Dwight D. Showalter, William A . Gooch, Matt S. Burkins, Victoria

  8. Shape Optimization of the Assisted Bi-directional Glenn surgery for stage-1 single ventricle palliation

    NASA Astrophysics Data System (ADS)

    Verma, Aekaansh; Shang, Jessica; Esmaily-Moghadam, Mahdi; Wong, Kwai; Marsden, Alison

    2016-11-01

    Babies born with a single functional ventricle typically undergo three open-heart surgeries starting as neonates. The first of these stages (BT shunt or Norwood) has the highest mortality rates of the three, approaching 30%. Proceeding directly to a stage-2 Glenn surgery has historically demonstrated inadequate pulmonary flow (PF) & high mortality. Recently, the Assisted Bi-directional Glenn (ABG) was proposed as a promising means to achieve a stable physiology by assisting the PF via an 'ejector pump' from the systemic circulation. We present preliminary parametrization and optimization results for the ABG geometry, with the goal of increasing PF. To limit excessive pressure increases in the Superior Vena Cava (SVC), the SVC pressure is included as a constraint. We use 3-D finite element flow simulations coupled with a single ventricle lumped parameter network to evaluate PF & the pressure constraint. We employ a derivative free optimization method- the Surrogate Management Framework, in conjunction with the OpenDIEL framework to simulate multiple simultaneous evaluations. Results show that nozzle diameter is the most important design parameter affecting ABG performance. The application of these results to patient specific situations will be discussed. This work was supported by an NSF CAREER award (OCI1150184) and by the XSEDE National Computing Resource.

  9. Experimental measurements of energy augmentation for mechanical circulatory assistance in a patient-specific Fontan model.

    PubMed

    Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L

    2014-09-01

    A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. A Field Portable Hyperspectral Goniometer for Coastal Characterization

    NASA Technical Reports Server (NTRS)

    Bachmann, Charles M.; Gray, Deric; Abelev, Andrei; Philpot, William; Fusina, Robert A.; Musser, Joseph A.; Vermillion, Michael; Doctor, Katarina; White, Maurice; Georgiev, Georgi

    2012-01-01

    During an airborne multi-sensor remote sensing experiment at the Virginia Coast Reserve (VCR) Long Term Ecological Research (LTER) site in June 2011 (VCR '11), first measurements were taken with the new NRL Goniometer for Outdoor Portable Hyperspectral Earth Reflectance (GOPHER). GOPHER measures the angular distribution of hyperspectral reflectance. GOPHER was constructed for NRL by Spectra Vista Corporation (SVC) and the University of Lethbridge through a capital equipment purchase in 2010. The GOPHER spectrometer is an SVC HR -1024, which measures hyperspectral reflectance over the range from 350 -2500 nm, the visible, near infrared, and short-wave infrared. During measurements, the spectrometer travels along a zenith quarter -arc track that can rotate in azimuth, allowing for measurement of the bi-directional reflectance distribution function (BRDF) over the whole hemisphere. The zenith arc has a radius of approximately 2m, and the spectrometer scan pattern can be programmed on the fly during calibration and validation efforts. The spectrometer and zenith arc assembly can be raised and lowered along a mast to allow for measurement of uneven terrain or vegetation canopies of moderate height. Hydraulics on the chassis allow for leveling of the instrument in the field. At just over 400 lbs, GOPHER is a field portable instrument and can be transformed into a compact trailer assembly for movement over long distances in the field.

  11. NSEG, a segmented mission analysis program for low and high speed aircraft. Volume 1: Theoretical development

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Rozendaal, H. L.

    1977-01-01

    A rapid mission analysis code based on the use of approximate flight path equations of motion is presented. Equation form varies with the segment type, for example, accelerations, climbs, cruises, descents, and decelerations. Realistic and detailed characteristics were specified in tabular form. The code also contains extensive flight envelope performance mapping capabilities. Approximate take off and landing analyses were performed. At high speeds, centrifugal lift effects were accounted for. Extensive turbojet and ramjet engine scaling procedures were incorporated in the code.

  12. Focus Group Research on the Implications of Adopting the Unified English Braille Code

    ERIC Educational Resources Information Center

    Wetzel, Robin; Knowlton, Marie

    2006-01-01

    Five focus groups explored concerns about adopting the Unified English Braille Code. The consensus was that while the proposed changes to the literary braille code would be minor, those to the mathematics braille code would be much more extensive. The participants emphasized that "any code that reduces the number of individuals who can access…

  13. NGEE Arctic Canopy Spectral Reflectance, Barrow, Alaska, 2014-2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shawn Serbin; Wil Lieberman-Cribbin; Kim Ely

    Measurements of full-spectrum (i.e. 350-2500nm) canopy spectral reflectance of Arctic plant species within the BEO, Barrow, Alaska. Spectra were collected using an Spectra Vista Corporation (SVC) HR-2014i and Spectral Evolution (SE) PSR+ instrument mounted on a tripod or monopod together with a Spectralon white plate to calibrate each measurement under variable illumination conditions. Data were collected in Barrow, Alaska during the 2014 to 2016 period.

  14. The Copula and Subject Complement Construction in English and Its Equivalents in Finnish. Contrastive Papers: Jyvaskyla Contrastive Studies, 4. Reports from the Department of English, No. 4.

    ERIC Educational Resources Information Center

    Hamalainen, Eila

    This paper discusses subject-verb-complement (SVC) clauses and their renderings in English and Finnish. Comparisons are made on the level of surface structure and with regard to equivalence in the sense of one construction being an optimum translation of the other. The definition of congruence, i.e., formal similarity and equal number of…

  15. To Determine the Impact of OPMS on the Development of Commanders.

    DTIC Science & Technology

    1982-04-19

    and training policies are designed to promote the development of leadership , managerial, and technical skills.5 In spite of the foregoing, there is...corps into commanders and staff, with the in- evitable consequence of each group convinced the other does not under- stand its problems . Further, the...developing leadership skills needed to effec- tively command troops* Caterory Label Combat Arms Combat Support Combat Svc Spt Strongly agree/agree 65% 58

  16. Effect of yoga practices on pulmonary function tests including transfer factor of lung for carbon monoxide (TLCO) in asthma patients.

    PubMed

    Singh, Savita; Soni, Ritu; Singh, K P; Tandon, O P

    2012-01-01

    Prana is the energy, when the self-energizing force embraces the body with extension and expansion and control, it is pranayama. It may affect the milieu at the bronchioles and the alveoli particularly at the alveolo-capillary membrane to facilitate diffusion and transport of gases. It may also increase oxygenation at tissue level. Aim of our study is to compare pulmonary functions and diffusion capacity in patients of bronchial asthma before and after yogic intervention of 2 months. Sixty stable asthmatic-patients were randomized into two groups i.e group 1 (Yoga training group) and group 2 (control group). Each group included thirty patients. Lung functions were recorded on all patients at baseline, and then after two months. Group 1 subjects showed a statistically significant improvement (P<0.001) in Transfer factor of the lung for carbon monoxide (TLCO), forced vital capacity (FVC), forced expiratory volume in 1st sec (FEV1), peak expiratory flow rate (PEFR), maximum voluntary ventilation (MVV) and slow vital capacity (SVC) after yoga practice. Quality of life also increased significantly. It was concluded that pranayama & yoga breathing and stretching postures are used to increase respiratory stamina, relax the chest muscles, expand the lungs, raise energy levels, and calm the body.

  17. Improvements to the nuclear model code GNASH for cross section calculations at higher energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, P.G.; Chadwick, M.B.

    1994-05-01

    The nuclear model code GNASH, which in the past has been used predominantly for incident particle energies below 20 MeV, has been modified extensively for calculations at higher energies. The model extensions and improvements are described in this paper, and their significance is illustrated by comparing calculations with experimental data for incident energies up to 160 MeV.

  18. NSEG: A segmented mission analysis program for low and high speed aircraft. Volume 2: Program users manual

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Rozendaal, H. L.

    1977-01-01

    A rapid mission analysis code based on the use of approximate flight path equations of motion is described. Equation form varies with the segment type, for example, accelerations, climbs, cruises, descents, and decelerations. Realistic and detailed vehicle characteristics are specified in tabular form. In addition to its mission performance calculation capabilities, the code also contains extensive flight envelop performance mapping capabilities. Approximate take off and landing analyses can be performed. At high speeds, centrifugal lift effects are taken into account. Extensive turbojet and ramjet engine scaling procedures are incorporated in the code.

  19. Using Machine Learning and Natural Language Processing Algorithms to Automate the Evaluation of Clinical Decision Support in Electronic Medical Record Systems.

    PubMed

    Szlosek, Donald A; Ferrett, Jonathan

    2016-01-01

    As the number of clinical decision support systems (CDSSs) incorporated into electronic medical records (EMRs) increases, so does the need to evaluate their effectiveness. The use of medical record review and similar manual methods for evaluating decision rules is laborious and inefficient. The authors use machine learning and Natural Language Processing (NLP) algorithms to accurately evaluate a clinical decision support rule through an EMR system, and they compare it against manual evaluation. Modeled after the EMR system EPIC at Maine Medical Center, we developed a dummy data set containing physician notes in free text for 3,621 artificial patients records undergoing a head computed tomography (CT) scan for mild traumatic brain injury after the incorporation of an electronic best practice approach. We validated the accuracy of the Best Practice Advisories (BPA) using three machine learning algorithms-C-Support Vector Classification (SVC), Decision Tree Classifier (DecisionTreeClassifier), k-nearest neighbors classifier (KNeighborsClassifier)-by comparing their accuracy for adjudicating the occurrence of a mild traumatic brain injury against manual review. We then used the best of the three algorithms to evaluate the effectiveness of the BPA, and we compared the algorithm's evaluation of the BPA to that of manual review. The electronic best practice approach was found to have a sensitivity of 98.8 percent (96.83-100.0), specificity of 10.3 percent, PPV = 7.3 percent, and NPV = 99.2 percent when reviewed manually by abstractors. Though all the machine learning algorithms were observed to have a high level of prediction, the SVC displayed the highest with a sensitivity 93.33 percent (92.49-98.84), specificity of 97.62 percent (96.53-98.38), PPV = 50.00, NPV = 99.83. The SVC algorithm was observed to have a sensitivity of 97.9 percent (94.7-99.86), specificity 10.30 percent, PPV 7.25 percent, and NPV 99.2 percent for evaluating the best practice approach, after accounting for 17 cases (0.66 percent) where the patient records had to be reviewed manually due to the NPL systems inability to capture the proper diagnosis. CDSSs incorporated into EMRs can be evaluated in an automatic fashion by using NLP and machine learning techniques.

  20. Lower-extremity isokinetic strength profiling in professional rugby league and rugby union.

    PubMed

    Brown, Scott R; Brughelli, Matt; Griffiths, Peter C; Cronin, John B

    2014-03-01

    While several studies have documented isokinetic knee strength in junior and senior rugby league players, investigations of isokinetic knee and hip strength in professional rugby union players are limited. The purpose of this study was to provide lower-extremity strength profiles and compare isokinetic knee and hip strength of professional rugby league and rugby union players. 32 professional rugby league and 25 professional rugby union players. Cross-sectional analysis. Isokinetic dynamometry was used to evaluate peak torque and strength ratios of the dominant and nondominant legs during seated knee-extension/ flexion and supine hip-extension/flexion actions at 60°/s. Forwards from both codes were taller and heavier and had a higher body-mass index than the backs of each code. Rugby union forwards produced significantly (P < .05) greater peak torque during knee flexion in the dominant and nondominant legs (ES = 1.81 and 2.02) compared with rugby league forwards. Rugby league backs produced significantly greater hip-extension peak torque in the dominant and nondominant legs (ES = 0.83 and 0.77) compared with rugby union backs. There were no significant differences in hamstring-to-quadriceps ratios between code, position, or leg. Rugby union forwards and backs produced significantly greater knee-flexion-to-hip-extension ratios in the dominant and nondominant legs (ES = 1.49-2.26) than rugby union players. It seems that the joint torque profiles of players from rugby league and union codes differ, which may be attributed to the different demands of each code.

  1. The JPEG XT suite of standards: status and future plans

    NASA Astrophysics Data System (ADS)

    Richter, Thomas; Bruylants, Tim; Schelkens, Peter; Ebrahimi, Touradj

    2015-09-01

    The JPEG standard has known an enormous market adoption. Daily, billions of pictures are created, stored and exchanged in this format. The JPEG committee acknowledges this success and spends continued efforts in maintaining and expanding the standard specifications. JPEG XT is a standardization effort targeting the extension of the JPEG features by enabling support for high dynamic range imaging, lossless and near-lossless coding, and alpha channel coding, while also guaranteeing backward and forward compatibility with the JPEG legacy format. This paper gives an overview of the current status of the JPEG XT standards suite. It discusses the JPEG legacy specification, and details how higher dynamic range support is facilitated both for integer and floating-point color representations. The paper shows how JPEG XT's support for lossless and near-lossless coding of low and high dynamic range images is achieved in combination with backward compatibility to JPEG legacy. In addition, the extensible boxed-based JPEG XT file format on which all following and future extensions of JPEG will be based is introduced. This paper also details how the lossy and lossless representations of alpha channels are supported to allow coding transparency information and arbitrarily shaped images. Finally, we conclude by giving prospects on upcoming JPEG standardization initiative JPEG Privacy & Security, and a number of other possible extensions in JPEG XT.

  2. Standard interface files and procedures for reactor physics codes, version III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, B.M.

    Standards and procedures for promoting the exchange of reactor physics codes are updated to Version-III status. Standards covering program structure, interface files, file handling subroutines, and card input format are included. The implementation status of the standards in codes and the extension of the standards to new code areas are summarized. (15 references) (auth)

  3. Dollar Summary of Federal Supply Classification and Service Category by Company, FY83, Part 5 (N065-W059).

    DTIC Science & Technology

    1983-01-01

    BLDGS 1,269 PHILLIPS SWAGER ASSOCIATES ILLINOIS ARMY A/E CONSTRUCTION /ADMIN 9 SVC BLDGS 174 QUINLIVIAN PIERIK KRAUSE ROBSON JV NEW YORK NAVY A/E...CONSTRUCTION /AIRFIELD & MSL FAC RANCORN WILDMAN & KRAUSE VIRGINIA NAVY A/E CONSTRUCTION /AIRFIELD & MSL FAC REED ALONZO B MASS ARMY A/E CONSTRUCTION...ARCHITECT/ENGINEER - GENERAL CONTRACTOR TOTAL OUADRA ENGINEERING INC ALASKA OCE ARCHITECT/ENGINEER - GENERAL QUINLIVAN PIERIK & KRAUSE MASS ARMY ARCHITECT

  4. A Cost-Comparison Study Using Actual CHAMPUS Formulas to Price Wilford Hall Medical Center’s FY 1993 Inpatient Workload to Determine Whether CHAMPUS is the More Cost-Effective Health Care Delivery System.

    DTIC Science & Technology

    1994-05-01

    PODIATRY AECA HAND SURGERY 3UB MED SVC MIL PER REC ACT TOTAL 0.00 558.00 558. 00 0.00 0.00 64.00 400.00 "袎.00 1022.00 ABIA PLASTIC...ABHA PEDIATRIC SURGERY ABHP PEDIATRIC SURGERY PART ABH SUBTOTAL ABIA PLASTIC SURGERY ABI SUBTOTAL ABKA UROLOGY _ ABK SUBTOTAL AA ORGAN

  5. Department of Clinical Investigation Annual Research Progress Report, Fiscal Year 1984. Volume 2,

    DTIC Science & Technology

    1984-10-01

    Brooke Army Medical Center Dept/Svc Associate Investigators: Department of Pediatrics Key Words: Ewing ’s sarcoma Accumulative MEDCASE Eat Accumulative...Modality Therapy for Disseminated Soft Tissue 289 Sarcomas , Phase III. (0) SWOG 8025 Combination Chemotherapy for Chronic Lymphocytic Leukemia. 290 *(C...Metastatic Islet Cell 318 Carcinoma, Phase I1. (0) SWOG 8209 A Study of AZQ in Soft Tissue and Bony Sarcomas , Phase 1I. 319 (C) SWOG 8210 A Comparison

  6. Ada (Trade Name) Bibliography. Volume 2.

    DTIC Science & Technology

    1984-03-01

    for every journal. The publisher information V,.0 appears if the document is a textbook. N % Xle r , , % 1= &-6 Ada Bibliography Volume 11 9 3. DOCUMENT...THE ADA LkNGUAGE SYSTEM PROJECT RAKITIN. STEVEN R . 6TH INT’L CONF ON SOFTWARE ENGINEERING: POSTER SESSION, PP. 49-50. 09/16/82 This paper discusses...VALIDATION AVAILABLE FROM: NATL.TECHNCL INF.SVC.5285 PORT ROYAL RD,SPRINGFIELD.VA SPONSORS: U.S.ARMY,COMMUNICATIONS R & D COMND, FT.MONMOUTH, NJ DOCUMENT

  7. Sharp Central Venous Recanalization by Means of a TIPS Needle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Honnef, Dagmar, E-mail: honnef@rad.rwth-aachen.de; Wingen, Markus; Guenther, Rolf W.

    The purpose of this study was to perform an alternative technique for recanalization of a chronic occlusion of the left brachiocephalic vein that could not be traversed with a guidewire. Restoration of a completely thrombosed left brachiocephalic vein was attempted in a 76-year-old male hemodialysis patient with massive upper inflow obstruction, massive edema of the face, neck, shoulder, and arm, and occlusion of the stented right brachiocephalic vein/superior vena cava. Vessel negotiation with several guidewires and multipurpose catheters proved unsuccessful. The procedure was also non-viable using a long, 21G puncture needle. Puncture of the superior vena cava (SVC) at themore » distal circumference of the stent in the right brachiocephalic vein/superior vena cava, however, was feasible with a transjugular intrahepatic portosystemic shunt (TIPS) set under biplanar fluoroscopy using the distal end of the right brachiocephalic vein as a target, followed by balloon dilatation and partial extraction of thrombotic material of the left brachiocephalic vein with a wire basket. Finally, two overlapping stents were deployed to avoid early re-occlusion. Venography demonstrated complete vessel patency with free contrast media flow via the stents into the SVC, which was reconfirmed in follow-up examinations. Immediate clinical improvement was observed. Venous vascular recanalization of chronic venous occlusion by means of a TIPS needle is feasible as a last resort under certain precautions.« less

  8. Warm storage for arc magmas

    NASA Astrophysics Data System (ADS)

    Barboni, Mélanie; Boehnke, Patrick; Schmitt, Axel K.; Harrison, T. Mark; Shane, Phil; Bouvier, Anne-Sophie; Baumgartner, Lukas

    2016-12-01

    Felsic magmatic systems represent the vast majority of volcanic activity that poses a threat to human life. The tempo and magnitude of these eruptions depends on the physical conditions under which magmas are retained within the crust. Recently the case has been made that volcanic reservoirs are rarely molten and only capable of eruption for durations as brief as 1,000 years following magma recharge. If the “cold storage” model is generally applicable, then geophysical detection of melt beneath volcanoes is likely a sign of imminent eruption. However, some arc volcanic centers have been active for tens of thousands of years and show evidence for the continual presence of melt. To address this seeming paradox, zircon geochronology and geochemistry from both the frozen lava and the cogenetic enclaves they host from the Soufrière Volcanic Center (SVC), a long-lived volcanic complex in the Lesser Antilles arc, were integrated to track the preeruptive thermal and chemical history of the magma reservoir. Our results show that the SVC reservoir was likely eruptible for periods of several tens of thousands of years or more with punctuated eruptions during these periods. These conclusions are consistent with results from other arc volcanic reservoirs and suggest that arc magmas are generally stored warm. Thus, the presence of intracrustal melt alone is insufficient as an indicator of imminent eruption, but instead represents the normal state of magma storage underneath dormant volcanoes.

  9. Radiofrequency wire for the recanalization of central vein occlusions that have failed conventional endovascular techniques.

    PubMed

    Guimaraes, Marcelo; Schonholz, Claudio; Hannegan, Christopher; Anderson, Michael Bret; Shi, June; Selby, Bayne

    2012-08-01

    To report the technique and acute technical results associated with the PowerWire Radiofrequency (RF) Guidewire used to recanalize central vein occlusions (CVOs) after the failure of conventional endovascular techniques. A retrospective study was conducted from January 2008 to December 2011, which identified all patients with CVOs who underwent treatment with a novel RF guide wire. Forty-two symptomatic patients (with swollen arm or superior vena cava [SVC] syndrome) underwent RF wire recanalization of 43 CVOs, which were then implanted with stents. The distribution of CVOs in central veins was as follows: six subclavian, 29 brachiocephalic, and eight SVC. All patients had a history of central venous catheter placement. Patients were monitored with regular clinical evaluations and central venography after treatment. All 42 patients had successful recanalization of CVOs facilitated by the RF wire technique. There was one complication, which was not directly related to the RF wire: one case of cardiac tamponade attributed to balloon angioplasty after stent placement. Forty of 42 patients (95.2%) had patent stents and were asymptomatic at 6 and 9 months after treatment. The present results suggest that the RF wire technique is a safe and efficient alternative in the recanalization of symptomatic and chronic CVOs when conventional endovascular techniques have failed. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  10. Surgical management of anomalous pulmonary venous connection to the superior vena cava - early results

    PubMed Central

    Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.

    2013-01-01

    Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880

  11. Warm storage for arc magmas.

    PubMed

    Barboni, Mélanie; Boehnke, Patrick; Schmitt, Axel K; Harrison, T Mark; Shane, Phil; Bouvier, Anne-Sophie; Baumgartner, Lukas

    2016-12-06

    Felsic magmatic systems represent the vast majority of volcanic activity that poses a threat to human life. The tempo and magnitude of these eruptions depends on the physical conditions under which magmas are retained within the crust. Recently the case has been made that volcanic reservoirs are rarely molten and only capable of eruption for durations as brief as 1,000 years following magma recharge. If the "cold storage" model is generally applicable, then geophysical detection of melt beneath volcanoes is likely a sign of imminent eruption. However, some arc volcanic centers have been active for tens of thousands of years and show evidence for the continual presence of melt. To address this seeming paradox, zircon geochronology and geochemistry from both the frozen lava and the cogenetic enclaves they host from the Soufrière Volcanic Center (SVC), a long-lived volcanic complex in the Lesser Antilles arc, were integrated to track the preeruptive thermal and chemical history of the magma reservoir. Our results show that the SVC reservoir was likely eruptible for periods of several tens of thousands of years or more with punctuated eruptions during these periods. These conclusions are consistent with results from other arc volcanic reservoirs and suggest that arc magmas are generally stored warm. Thus, the presence of intracrustal melt alone is insufficient as an indicator of imminent eruption, but instead represents the normal state of magma storage underneath dormant volcanoes.

  12. Warm storage for arc magmas

    PubMed Central

    Barboni, Mélanie; Schmitt, Axel K.; Harrison, T. Mark; Shane, Phil; Bouvier, Anne-Sophie; Baumgartner, Lukas

    2016-01-01

    Felsic magmatic systems represent the vast majority of volcanic activity that poses a threat to human life. The tempo and magnitude of these eruptions depends on the physical conditions under which magmas are retained within the crust. Recently the case has been made that volcanic reservoirs are rarely molten and only capable of eruption for durations as brief as 1,000 years following magma recharge. If the “cold storage” model is generally applicable, then geophysical detection of melt beneath volcanoes is likely a sign of imminent eruption. However, some arc volcanic centers have been active for tens of thousands of years and show evidence for the continual presence of melt. To address this seeming paradox, zircon geochronology and geochemistry from both the frozen lava and the cogenetic enclaves they host from the Soufrière Volcanic Center (SVC), a long-lived volcanic complex in the Lesser Antilles arc, were integrated to track the preeruptive thermal and chemical history of the magma reservoir. Our results show that the SVC reservoir was likely eruptible for periods of several tens of thousands of years or more with punctuated eruptions during these periods. These conclusions are consistent with results from other arc volcanic reservoirs and suggest that arc magmas are generally stored warm. Thus, the presence of intracrustal melt alone is insufficient as an indicator of imminent eruption, but instead represents the normal state of magma storage underneath dormant volcanoes. PMID:27799558

  13. Software Model Checking of ARINC-653 Flight Code with MCP

    NASA Technical Reports Server (NTRS)

    Thompson, Sarah J.; Brat, Guillaume; Venet, Arnaud

    2010-01-01

    The ARINC-653 standard defines a common interface for Integrated Modular Avionics (IMA) code. In particular, ARINC-653 Part 1 specifies a process- and partition-management API that is analogous to POSIX threads, but with certain extensions and restrictions intended to support the implementation of high reliability flight code. MCP is a software model checker, developed at NASA Ames, that provides capabilities for model checking C and C++ source code. In this paper, we present recent work aimed at implementing extensions to MCP that support ARINC-653, and we discuss the challenges and opportunities that consequentially arise. Providing support for ARINC-653 s time and space partitioning is nontrivial, though there are implicit benefits for partial order reduction possible as a consequence of the API s strict interprocess communication policy.

  14. New features in the design code Tlie

    NASA Astrophysics Data System (ADS)

    van Zeijts, Johannes

    1993-12-01

    We present features recently installed in the arbitrary-order accelerator design code Tlie. The code uses the MAD input language, and implements programmable extensions modeled after the C language that make it a powerful tool in a wide range of applications: from basic beamline design to high precision-high order design and even control room applications. The basic quantities important in accelerator design are easily accessible from inside the control language. Entities like parameters in elements (strength, current), transfer maps (either in Taylor series or in Lie algebraic form), lines, and beams (either as sets of particles or as distributions) are among the type of variables available. These variables can be set, used as arguments in subroutines, or just typed out. The code is easily extensible with new datatypes.

  15. A validation of LTRAN2 with high frequency extensions by comparisons with experimental measurements of unsteady transonic flows

    NASA Technical Reports Server (NTRS)

    Hessenius, K. A.; Goorjian, P. M.

    1981-01-01

    A high frequency extension of the unsteady, transonic code LTRAN2 was created and is evaluated by comparisons with experimental results. The experimental test case is a NACA 64A010 airfoil in pitching motion at a Mach number of 0.8 over a range of reduced frequencies. Comparisons indicate that the modified code is an improvement of the original LTRAN2 and provides closer agreement with experimental lift and moment coefficients. A discussion of the code modifications, which involve the addition of high frequency terms of the boundary conditions of the numerical algorithm, is included.

  16. Building code compliance and enforcement: The experience of San Francisco's residential energy conservation ordinance and California's building standards for new construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    1990-11-01

    As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing to construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. 12 refs., 5 tabs.« less

  17. Building Code Compliance and Enforcement: The Experience of SanFrancisco's Residential Energy Conservation Ordinanace and California'sBuildign Standards for New Construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    1990-11-01

    As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. Because statewide codes are enforced by local officials, these problems may increase over time as energy standards change and become more complex and as other standards (eg, health and safety codes) remain a higher priority. The California Energy Commission realizes that code enforcement by itself is insufficient and expects that additional educational and technical assistance efforts (eg, manuals, training programs, and toll-free telephone lines) will ameliorate these problems.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later.

  19. Scouts Out! The Development of Reconnaissance Units in Modern Armies

    DTIC Science & Technology

    2008-01-01

    Waffen -SS im Zweiten Weltkrieg 1939–1945, Band 2: Die Landstreitkräfte. Nrn. 1-5 (Osnabrück, GE: Biblio Verlag, 1973), 175. As an exception to light...tracks.37 Later in the war, the Waffen SS developed into a major armored component of the German Armed Forces. Waffen SS divisions, including their...was the Waffen SS, a component of the German land forces in World War II) svc service T tng training TOE table of

  20. Data compression for satellite images

    NASA Technical Reports Server (NTRS)

    Chen, P. H.; Wintz, P. A.

    1976-01-01

    An efficient data compression system is presented for satellite pictures and two grey level pictures derived from satellite pictures. The compression techniques take advantages of the correlation between adjacent picture elements. Several source coding methods are investigated. Double delta coding is presented and shown to be the most efficient. Both predictive differential quantizing technique and double delta coding can be significantly improved by applying a background skipping technique. An extension code is constructed. This code requires very little storage space and operates efficiently. Simulation results are presented for various coding schemes and source codes.

  1. Friendly Extensible Transfer Tool Beta Version

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, William P.; Gutierrez, Kenneth M.; McRee, Susan R.

    2016-04-15

    Often data transfer software is designed to meet specific requirements or apply to specific environments. Frequently, this requires source code integration for added functionality. An extensible data transfer framework is needed to more easily incorporate new capabilities, in modular fashion. Using FrETT framework, functionality may be incorporated (in many cases without need of source code) to handle new platform capabilities: I/O methods (e.g., platform specific data access), network transport methods, data processing (e.g., data compression.).

  2. Entropy-Based Bounds On Redundancies Of Huffman Codes

    NASA Technical Reports Server (NTRS)

    Smyth, Padhraic J.

    1992-01-01

    Report presents extension of theory of redundancy of binary prefix code of Huffman type which includes derivation of variety of bounds expressed in terms of entropy of source and size of alphabet. Recent developments yielded bounds on redundancy of Huffman code in terms of probabilities of various components in source alphabet. In practice, redundancies of optimal prefix codes often closer to 0 than to 1.

  3. Flexible Generation of Kalman Filter Code

    NASA Technical Reports Server (NTRS)

    Richardson, Julian; Wilson, Edward

    2006-01-01

    Domain-specific program synthesis can automatically generate high quality code in complex domains from succinct specifications, but the range of programs which can be generated by a given synthesis system is typically narrow. Obtaining code which falls outside this narrow scope necessitates either 1) extension of the code generator, which is usually very expensive, or 2) manual modification of the generated code, which is often difficult and which must be redone whenever changes are made to the program specification. In this paper, we describe adaptations and extensions of the AUTOFILTER Kalman filter synthesis system which greatly extend the range of programs which can be generated. Users augment the input specification with a specification of code fragments and how those fragments should interleave with or replace parts of the synthesized filter. This allows users to generate a much wider range of programs without their needing to modify the synthesis system or edit generated code. We demonstrate the usefulness of the approach by applying it to the synthesis of a complex state estimator which combines code from several Kalman filters with user-specified code. The work described in this paper allows the complex design decisions necessary for real-world applications to be reflected in the synthesized code. When executed on simulated input data, the generated state estimator was found to produce comparable estimates to those produced by a handcoded estimator

  4. Multiple Neuropeptide-Coding Genes Involved in Planarian Pharynx Extension.

    PubMed

    Shimoyama, Seira; Inoue, Takeshi; Kashima, Makoto; Agata, Kiyokazu

    2016-06-01

    Planarian feeding behavior involves three steps: moving toward food, extending the pharynx from their planarian's ventral side after arriving at the food, and ingesting the food through the pharynx. Although pharynx extension is a remarkable behavior, it remains unknown what neuronal cell types are involved in its regulation. To identify neurons involved in regulating pharynx extension, we quantitatively analyzed pharynx extension and sought to identify these neurons by RNA interference (RNAi) and in situ hybridization. This assay, when performed using planarians with amputation of various body parts, clearly showed that the head portion is indispensable for inducing pharynx extension. We thus tested the effects of knockdown of brain neurons such as serotonergic, GABAergic, and dopaminergic neurons by RNAi, but did not observe any effects on pharynx extension behavior. However, animals with RNAi of the Prohormone Convertase 2 (PC2, a neuropeptide processing enzyme) gene did not perform the pharynx extension behavior, suggesting the possible involvement of neuropeptide(s in the regulation of pharynx extension. We screened 24 neuropeptide-coding genes, analyzed their functions by RNAi using the pharynx extension assay system, and identified at least five neuropeptide genes involved in pharynx extension. These was expressed in different cells or neurons, and some of them were expressed in the brain, suggesting complex regulation of planarian feeding behavior by the nervous system.

  5. 78 FR 59265 - FD&C Yellow No. 5; Exemption From the Requirement of a Tolerance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... (NAICS code 112). Food manufacturing (NAICS code 311). Pesticide manufacturing (NAICS code 32532). B. How.... 5 is a FDA permanently listed color additive used in food, drugs and cosmetics, including drugs and cosmetics for the eye area. FDA's color additive evaluation included the consideration of an extensive set...

  6. Modernization and optimization of a legacy open-source CFD code for high-performance computing architectures

    NASA Astrophysics Data System (ADS)

    Gel, Aytekin; Hu, Jonathan; Ould-Ahmed-Vall, ElMoustapha; Kalinkin, Alexander A.

    2017-02-01

    Legacy codes remain a crucial element of today's simulation-based engineering ecosystem due to the extensive validation process and investment in such software. The rapid evolution of high-performance computing architectures necessitates the modernization of these codes. One approach to modernization is a complete overhaul of the code. However, this could require extensive investments, such as rewriting in modern languages, new data constructs, etc., which will necessitate systematic verification and validation to re-establish the credibility of the computational models. The current study advocates using a more incremental approach and is a culmination of several modernization efforts of the legacy code MFIX, which is an open-source computational fluid dynamics code that has evolved over several decades, widely used in multiphase flows and still being developed by the National Energy Technology Laboratory. Two different modernization approaches,'bottom-up' and 'top-down', are illustrated. Preliminary results show up to 8.5x improvement at the selected kernel level with the first approach, and up to 50% improvement in total simulated time with the latter were achieved for the demonstration cases and target HPC systems employed.

  7. Various mechanisms and clinical phenotypes in electrical short circuits of high-voltage devices: report of four cases and review of the literature.

    PubMed

    Tsurugi, Takuo; Matsui, Shogo; Nakajima, Hiroshi; Nishii, Nobuhiro; Honda, Toshihiro; Kaneko, Yoshiaki

    2015-06-01

    An electrical short circuit is a rare complication in a high-voltage implantable cardioverter-defibrillator (ICD). However, the inability of an ICD to deliver appropriate shock therapy can be life-threatening. During the last 2 years, four cases of serious complications related to an electrical short circuit have been reported in Japan. A spark due to an electrical short circuit resulted in the failure of an ICD shock to terminate ventricular tachycardia and total damage to the ICD generator in three of four cases. Two of the four patients died from an electrical short circuit between the right ventricle and superior vena cava (SVC) leads. The others had audible sounds from the ICD generator site and were diagnosed with a lead-to-can abrasion, which was manifested by the arc mark on the surface of the can. It is still difficult to predict the occurrence of an electrical short circuit in current ICD systems. To reduce the probability of an electrical short circuit, we suggest the following: (i) avoid lead stress at ICD implantation, (ii) select a single-coil lead instead of a dual-coil lead, or (iii) use a unique algorithm which automatically disconnect can or SVC lead from shock deliver circuit when excessive current was detected. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  8. The mid-sternal length, a practical anatomical landmark for optimal positioning of long-term central venous catheters

    PubMed Central

    Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah

    2013-01-01

    Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941

  9. Anatomy of the patent foramen ovale for the interventionalist.

    PubMed

    McKenzie, Jeff A; Edwards, William D; Hagler, Donald J

    2009-05-01

    Patent foramen ovale (PFO) is an interatrial communication whose management is controversial. Several manufacturers have submitted protocols for Food and Drug Administration (FDA) approval of their PFO closure device. The purpose of this study was to define anatomy relevant to percutaneous PFO closure, validate the clinical observation that most PFOs contain little tissue rim at the aorta, comment on proposed closure guidelines, and to discuss approaches to PFO closure. From the Mayo Clinic Tissue Registry, five normal hearts with PFO were selected from each sex from the first 10 decades of life (n = 100). Measurements (mm) included PFO length, diameter, and distance from FO-superior vena cava (SVC) and FO-aortic annulus (AoAn). Patient age, weight, and height were obtained from autopsy reports, and body surface area (BSA) was calculated. PFO length and diameter increased with age (P = 0.029 and 0.001, respectively), and FO-SVC and FO-AoAn increased with BSA (P

  10. Study of computerized spirometric parameters of traffic police personnel of Saurashtra region, Gujarat, India.

    PubMed

    Makwana, Amit H; Solanki, Jayesh D; Gokhale, Pradnya A; Mehta, Hemant B; Shah, Chinmay J; Gadhavi, Bhakti P

    2015-01-01

    Air pollution due to road traffic is a serious health hazard and air quality crisis in cities is mainly due to vehicular emission. Thus the persons who are continuously exposed are at an increased risk. The study was carried out to evaluate the extent of impairment in lung function in traffic police personnel compared to matched unexposed control group. A cross-sectional study was conducted to measure the spirometric parameters of 100 traffic police personnel, aged 20-55 years, working in Saurashtra region, as compared to matched control group, consisting of 100 unexposed males. Measurement of lung volumes and capacities was done with SPIROEXCEL. The statistical analysis was carried out with Graph pad instat 3. Traffic police personnel had significantly declined forced vital capacity (FVC), forced expiratory volume in one second (FEV 1), slow vital capacity (SVC) and maximum voluntary ventilation (MVV) when compared with predictive normal values, which is probably due to exposure to vehicular exhaust. Comparison of test values between groups showed significantly reduced FVC, MVV and increased FEV1/FVC ratio and insignificantly declined FEV1 and SVC in cases as compared to controls. Traffic personnel with longer duration of exposure showed significantly reduced lung functions than those with shorter duration. Smokers showed lower test values as compared to non-smokers with significance only in unexposed group. The effect of pollution by vehicular exhausts may be responsible for these pulmonary function impairments and traffic police personnel should be offered personal protective or preventive measures.

  11. Collisional tests and an extension of the TEMPEST continuum gyrokinetic code

    NASA Astrophysics Data System (ADS)

    Cohen, R. H.; Dorr, M.; Hittinger, J.; Kerbel, G.; Nevins, W. M.; Rognlien, T.; Xiong, Z.; Xu, X. Q.

    2006-04-01

    An important requirement of a kinetic code for edge plasmas is the ability to accurately treat the effect of colllisions over a broad range of collisionalities. To test the interaction of collisions and parallel streaming, TEMPEST has been compared with published analytic and numerical (Monte Carlo, bounce-averaged Fokker-Planck) results for endloss of particles confined by combined electrostatic and magnetic wells. Good agreement is found over a wide range of collisionality, confining potential and mirror ratio, and the required velocity space resolution is modest. We also describe progress toward extension of (4-dimensional) TEMPEST into a ``kinetic edge transport code'' (a kinetic counterpart of UEDGE). The extension includes averaging of the gyrokinetic equations over fast timescales and approximating the averaged quadratic terms by diffusion terms which respect the boundaries of inaccessable regions in phase space. F. Najmabadi, R.W. Conn and R.H. Cohen, Nucl. Fusion 24, 75 (1984); T.D. Rognlien and T.A. Cutler, Nucl. Fusion 20, 1003 (1980).

  12. N-body simulation for self-gravitating collisional systems with a new SIMD instruction set extension to the x86 architecture, Advanced Vector eXtensions

    NASA Astrophysics Data System (ADS)

    Tanikawa, Ataru; Yoshikawa, Kohji; Okamoto, Takashi; Nitadori, Keigo

    2012-02-01

    We present a high-performance N-body code for self-gravitating collisional systems accelerated with the aid of a new SIMD instruction set extension of the x86 architecture: Advanced Vector eXtensions (AVX), an enhanced version of the Streaming SIMD Extensions (SSE). With one processor core of Intel Core i7-2600 processor (8 MB cache and 3.40 GHz) based on Sandy Bridge micro-architecture, we implemented a fourth-order Hermite scheme with individual timestep scheme ( Makino and Aarseth, 1992), and achieved the performance of ˜20 giga floating point number operations per second (GFLOPS) for double-precision accuracy, which is two times and five times higher than that of the previously developed code implemented with the SSE instructions ( Nitadori et al., 2006b), and that of a code implemented without any explicit use of SIMD instructions with the same processor core, respectively. We have parallelized the code by using so-called NINJA scheme ( Nitadori et al., 2006a), and achieved ˜90 GFLOPS for a system containing more than N = 8192 particles with 8 MPI processes on four cores. We expect to achieve about 10 tera FLOPS (TFLOPS) for a self-gravitating collisional system with N ˜ 10 5 on massively parallel systems with at most 800 cores with Sandy Bridge micro-architecture. This performance will be comparable to that of Graphic Processing Unit (GPU) cluster systems, such as the one with about 200 Tesla C1070 GPUs ( Spurzem et al., 2010). This paper offers an alternative to collisional N-body simulations with GRAPEs and GPUs.

  13. Research on Automatic Programming

    DTIC Science & Technology

    1975-12-31

    Sequential processes, deadlocks, and semaphore primitives , Ph.D. Thesis, Harvard University, November 1974; Center for Research in Computing...verified. 13 Code generated to effect the synchronization makes use of the ECL control extension facility (Prenner’s CI, see [Prenner]). The... semaphore operations [Dijkstra] is being developed. Initial results for this code generator are very encouraging; in many cases generated code is

  14. A glacier runoff extension to the Precipitation Runoff Modeling System

    Treesearch

    A. E. Van Beusekom; R. J. Viger

    2016-01-01

    A module to simulate glacier runoff, PRMSglacier, was added to PRMS (Precipitation Runoff Modeling System), a distributed-parameter, physical-process hydrological simulation code. The extension does not require extensive on-glacier measurements or computational expense but still relies on physical principles over empirical relations as much as is feasible while...

  15. Vectorization of a classical trajectory code on a floating point systems, Inc. Model 164 attached processor.

    PubMed

    Kraus, Wayne A; Wagner, Albert F

    1986-04-01

    A triatomic classical trajectory code has been modified by extensive vectorization of the algorithms to achieve much improved performance on an FPS 164 attached processor. Extensive timings on both the FPS 164 and a VAX 11/780 with floating point accelerator are presented as a function of the number of trajectories simultaneously run. The timing tests involve a potential energy surface of the LEPS variety and trajectories with 1000 time steps. The results indicate that vectorization results in timing improvements on both the VAX and the FPS. For larger numbers of trajectories run simultaneously, up to a factor of 25 improvement in speed occurs between VAX and FPS vectorized code. Copyright © 1986 John Wiley & Sons, Inc.

  16. Support of Multidimensional Parallelism in the OpenMP Programming Model

    NASA Technical Reports Server (NTRS)

    Jin, Hao-Qiang; Jost, Gabriele

    2003-01-01

    OpenMP is the current standard for shared-memory programming. While providing ease of parallel programming, the OpenMP programming model also has limitations which often effect the scalability of applications. Examples for these limitations are work distribution and point-to-point synchronization among threads. We propose extensions to the OpenMP programming model which allow the user to easily distribute the work in multiple dimensions and synchronize the workflow among the threads. The proposed extensions include four new constructs and the associated runtime library. They do not require changes to the source code and can be implemented based on the existing OpenMP standard. We illustrate the concept in a prototype translator and test with benchmark codes and a cloud modeling code.

  17. A Network Coding Based Hybrid ARQ Protocol for Underwater Acoustic Sensor Networks

    PubMed Central

    Wang, Hao; Wang, Shilian; Zhang, Eryang; Zou, Jianbin

    2016-01-01

    Underwater Acoustic Sensor Networks (UASNs) have attracted increasing interest in recent years due to their extensive commercial and military applications. However, the harsh underwater channel causes many challenges for the design of reliable underwater data transport protocol. In this paper, we propose an energy efficient data transport protocol based on network coding and hybrid automatic repeat request (NCHARQ) to ensure reliability, efficiency and availability in UASNs. Moreover, an adaptive window length estimation algorithm is designed to optimize the throughput and energy consumption tradeoff. The algorithm can adaptively change the code rate and can be insensitive to the environment change. Extensive simulations and analysis show that NCHARQ significantly reduces energy consumption with short end-to-end delay. PMID:27618044

  18. NSEG: A segmented mission analysis program for low and high speed aircraft. Volume 3: Demonstration problems

    NASA Technical Reports Server (NTRS)

    Hague, D. S.; Rozendaal, H. L.

    1977-01-01

    Program NSEG is a rapid mission analysis code based on the use of approximate flight path equations of motion. Equation form varies with the segment type, for example, accelerations, climbs, cruises, descents, and decelerations. Realistic and detailed vehicle characteristics are specified in tabular form. In addition to its mission performance calculation capabilities, the code also contains extensive flight envelope performance mapping capabilities. For example, rate-of-climb, turn rates, and energy maneuverability parameter values may be mapped in the Mach-altitude plane. Approximate take off and landing analyses are also performed. At high speeds, centrifugal lift effects are accounted for. Extensive turbojet and ramjet engine scaling procedures are incorporated in the code.

  19. Kernel PLS-SVC for Linear and Nonlinear Discrimination

    NASA Technical Reports Server (NTRS)

    Rosipal, Roman; Trejo, Leonard J.; Matthews, Bryan

    2003-01-01

    A new methodology for discrimination is proposed. This is based on kernel orthonormalized partial least squares (PLS) dimensionality reduction of the original data space followed by support vector machines for classification. Close connection of orthonormalized PLS and Fisher's approach to linear discrimination or equivalently with canonical correlation analysis is described. This gives preference to use orthonormalized PLS over principal component analysis. Good behavior of the proposed method is demonstrated on 13 different benchmark data sets and on the real world problem of the classification finger movement periods versus non-movement periods based on electroencephalogram.

  20. Extension of a System Level Tool for Component Level Analysis

    NASA Technical Reports Server (NTRS)

    Majumdar, Alok; Schallhorn, Paul

    2002-01-01

    This paper presents an extension of a numerical algorithm for network flow analysis code to perform multi-dimensional flow calculation. The one dimensional momentum equation in network flow analysis code has been extended to include momentum transport due to shear stress and transverse component of velocity. Both laminar and turbulent flows are considered. Turbulence is represented by Prandtl's mixing length hypothesis. Three classical examples (Poiseuille flow, Couette flow and shear driven flow in a rectangular cavity) are presented as benchmark for the verification of the numerical scheme.

  1. Extension of a System Level Tool for Component Level Analysis

    NASA Technical Reports Server (NTRS)

    Majumdar, Alok; Schallhorn, Paul; McConnaughey, Paul K. (Technical Monitor)

    2001-01-01

    This paper presents an extension of a numerical algorithm for network flow analysis code to perform multi-dimensional flow calculation. The one dimensional momentum equation in network flow analysis code has been extended to include momentum transport due to shear stress and transverse component of velocity. Both laminar and turbulent flows are considered. Turbulence is represented by Prandtl's mixing length hypothesis. Three classical examples (Poiseuille flow, Couette flow, and shear driven flow in a rectangular cavity) are presented as benchmark for the verification of the numerical scheme.

  2. Runtime Detection of C-Style Errors in UPC Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pirkelbauer, P; Liao, C; Panas, T

    2011-09-29

    Unified Parallel C (UPC) extends the C programming language (ISO C 99) with explicit parallel programming support for the partitioned global address space (PGAS), which provides a global memory space with localized partitions to each thread. Like its ancestor C, UPC is a low-level language that emphasizes code efficiency over safety. The absence of dynamic (and static) safety checks allows programmer oversights and software flaws that can be hard to spot. In this paper, we present an extension of a dynamic analysis tool, ROSE-Code Instrumentation and Runtime Monitor (ROSECIRM), for UPC to help programmers find C-style errors involving the globalmore » address space. Built on top of the ROSE source-to-source compiler infrastructure, the tool instruments source files with code that monitors operations and keeps track of changes to the system state. The resulting code is linked to a runtime monitor that observes the program execution and finds software defects. We describe the extensions to ROSE-CIRM that were necessary to support UPC. We discuss complications that arise from parallel code and our solutions. We test ROSE-CIRM against a runtime error detection test suite, and present performance results obtained from running error-free codes. ROSE-CIRM is released as part of the ROSE compiler under a BSD-style open source license.« less

  3. Modernization and optimization of a legacy open-source CFD code for high-performance computing architectures

    DOE PAGES

    Gel, Aytekin; Hu, Jonathan; Ould-Ahmed-Vall, ElMoustapha; ...

    2017-03-20

    Legacy codes remain a crucial element of today's simulation-based engineering ecosystem due to the extensive validation process and investment in such software. The rapid evolution of high-performance computing architectures necessitates the modernization of these codes. One approach to modernization is a complete overhaul of the code. However, this could require extensive investments, such as rewriting in modern languages, new data constructs, etc., which will necessitate systematic verification and validation to re-establish the credibility of the computational models. The current study advocates using a more incremental approach and is a culmination of several modernization efforts of the legacy code MFIX, whichmore » is an open-source computational fluid dynamics code that has evolved over several decades, widely used in multiphase flows and still being developed by the National Energy Technology Laboratory. Two different modernization approaches,‘bottom-up’ and ‘top-down’, are illustrated. Here, preliminary results show up to 8.5x improvement at the selected kernel level with the first approach, and up to 50% improvement in total simulated time with the latter were achieved for the demonstration cases and target HPC systems employed.« less

  4. Modernization and optimization of a legacy open-source CFD code for high-performance computing architectures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gel, Aytekin; Hu, Jonathan; Ould-Ahmed-Vall, ElMoustapha

    Legacy codes remain a crucial element of today's simulation-based engineering ecosystem due to the extensive validation process and investment in such software. The rapid evolution of high-performance computing architectures necessitates the modernization of these codes. One approach to modernization is a complete overhaul of the code. However, this could require extensive investments, such as rewriting in modern languages, new data constructs, etc., which will necessitate systematic verification and validation to re-establish the credibility of the computational models. The current study advocates using a more incremental approach and is a culmination of several modernization efforts of the legacy code MFIX, whichmore » is an open-source computational fluid dynamics code that has evolved over several decades, widely used in multiphase flows and still being developed by the National Energy Technology Laboratory. Two different modernization approaches,‘bottom-up’ and ‘top-down’, are illustrated. Here, preliminary results show up to 8.5x improvement at the selected kernel level with the first approach, and up to 50% improvement in total simulated time with the latter were achieved for the demonstration cases and target HPC systems employed.« less

  5. Java Source Code Analysis for API Migration to Embedded Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winter, Victor; McCoy, James A.; Guerrero, Jonathan

    Embedded systems form an integral part of our technological infrastructure and oftentimes play a complex and critical role within larger systems. From the perspective of reliability, security, and safety, strong arguments can be made favoring the use of Java over C in such systems. In part, this argument is based on the assumption that suitable subsets of Java’s APIs and extension libraries are available to embedded software developers. In practice, a number of Java-based embedded processors do not support the full features of the JVM. For such processors, source code migration is a mechanism by which key abstractions offered bymore » APIs and extension libraries can made available to embedded software developers. The analysis required for Java source code-level library migration is based on the ability to correctly resolve element references to their corresponding element declarations. A key challenge in this setting is how to perform analysis for incomplete source-code bases (e.g., subsets of libraries) from which types and packages have been omitted. This article formalizes an approach that can be used to extend code bases targeted for migration in such a manner that the threats associated the analysis of incomplete code bases are eliminated.« less

  6. Implementation issues in source coding

    NASA Technical Reports Server (NTRS)

    Sayood, Khalid; Chen, Yun-Chung; Hadenfeldt, A. C.

    1989-01-01

    An edge preserving image coding scheme which can be operated in both a lossy and a lossless manner was developed. The technique is an extension of the lossless encoding algorithm developed for the Mars observer spectral data. It can also be viewed as a modification of the DPCM algorithm. A packet video simulator was also developed from an existing modified packet network simulator. The coding scheme for this system is a modification of the mixture block coding (MBC) scheme described in the last report. Coding algorithms for packet video were also investigated.

  7. A high temperature fatigue life prediction computer code based on the total strain version of StrainRange Partitioning (SRP)

    NASA Technical Reports Server (NTRS)

    Mcgaw, Michael A.; Saltsman, James F.

    1993-01-01

    A recently developed high-temperature fatigue life prediction computer code is presented and an example of its usage given. The code discussed is based on the Total Strain version of Strainrange Partitioning (TS-SRP). Included in this code are procedures for characterizing the creep-fatigue durability behavior of an alloy according to TS-SRP guidelines and predicting cyclic life for complex cycle types for both isothermal and thermomechanical conditions. A reasonably extensive materials properties database is included with the code.

  8. An Extension to the Constructivist Coding Hypothesis as a Learning Model for Selective Feedback when the Base Rate Is High

    ERIC Educational Resources Information Center

    Ghaffarzadegan, Navid; Stewart, Thomas R.

    2011-01-01

    Elwin, Juslin, Olsson, and Enkvist (2007) and Henriksson, Elwin, and Juslin (2010) offered the constructivist coding hypothesis to describe how people code the outcomes of their decisions when availability of feedback is conditional on the decision. They provided empirical evidence only for the 0.5 base rate condition. This commentary argues that…

  9. Development and application of structural dynamics analysis capabilities

    NASA Technical Reports Server (NTRS)

    Heinemann, Klaus W.; Hozaki, Shig

    1994-01-01

    Extensive research activities were performed in the area of multidisciplinary modeling and simulation of aerospace vehicles that are relevant to NASA Dryden Flight Research Facility. The efforts involved theoretical development, computer coding, and debugging of the STARS code. New solution procedures were developed in such areas as structures, CFD, and graphics, among others. Furthermore, systems-oriented codes were developed for rendering the code truly multidisciplinary and rather automated in nature. Also, work was performed in pre- and post-processing of engineering analysis data.

  10. New features and applications of PRESTO, a computer code for the performance of regenerative, superheated steam turbine cycles

    NASA Technical Reports Server (NTRS)

    Choo, Y. K.; Staiger, P. J.

    1982-01-01

    The code was designed to analyze performance at valves-wide-open design flow. The code can model conventional steam cycles as well as cycles that include such special features as process steam extraction and induction and feedwater heating by external heat sources. Convenience features and extensions to the special features were incorporated into the PRESTO code. The features are described, and detailed examples illustrating the use of both the original and the special features are given.

  11. Neural Decoder for Topological Codes

    NASA Astrophysics Data System (ADS)

    Torlai, Giacomo; Melko, Roger G.

    2017-07-01

    We present an algorithm for error correction in topological codes that exploits modern machine learning techniques. Our decoder is constructed from a stochastic neural network called a Boltzmann machine, of the type extensively used in deep learning. We provide a general prescription for the training of the network and a decoding strategy that is applicable to a wide variety of stabilizer codes with very little specialization. We demonstrate the neural decoder numerically on the well-known two-dimensional toric code with phase-flip errors.

  12. Additional extensions to the NASCAP computer code, volume 2

    NASA Technical Reports Server (NTRS)

    Stannard, P. R.; Katz, I.; Mandell, M. J.

    1982-01-01

    Particular attention is given to comparison of the actural response of the SCATHA (Spacecraft Charging AT High Altitudes) P78-2 satellite with theoretical (NASCAP) predictions. Extensive comparisons for a variety of environmental conditions confirm the validity of the NASCAP model. A summary of the capabilities and range of validity of NASCAP is presented, with extensive reference to previously published applications. It is shown that NASCAP is capable of providing quantitatively accurate results when the object and environment are adequately represented and fall within the range of conditions for which NASCAP was intended. Three dimensional electric field affects play an important role in determining the potential of dielectric surfaces and electrically isolated conducting surfaces, particularly in the presence of artificially imposed high voltages. A theory for such phenomena is presented and applied to the active control experiments carried out in SCATHA, as well as other space and laboratory experiments. Finally, some preliminary work toward modeling large spacecraft in polar Earth orbit is presented. An initial physical model is presented including charge emission. A simple code based upon the model is described along with code test results.

  13. 78 FR 23548 - Extension of Public Comment Period for the Draft Environmental Impact Statement for U.S. Navy F...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-19

    ... period ends on April 22, 2013. This notice announces an extension of the public comment period until May.... SUPPLEMENTARY INFORMATION: This notice announces an extension of the public comment period until May 7, 2013. Comments may be submitted in writing to Naval Facilities Engineering Command Southwest, Attn: Code EV21.AK...

  14. Peroperative electrocardiographic control of catheter tip position during implantation of femoral venous ports.

    PubMed

    Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis

    2015-01-01

    Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.

  15. Non-canonical Wnt signaling enhances differentiation of Sca1+/c-kit+ adipose-derived murine stromal vascular cells into spontaneously beating cardiac myocytes.

    PubMed

    Palpant, Nathan J; Yasuda, So-ichiro; MacDougald, Ormond; Metzger, Joseph M

    2007-09-01

    Recent reports have described a stem cell population termed stromal vascular cells (SVCs) derived from the stromal vascular fraction of adipose tissue, which are capable of intrinsic differentiation into spontaneously beating cardiomyocytes in vitro. The objective of this study was to further define the cardiac lineage differentiation potential of SVCs in vitro and to establish methods for enriching SVC-derived beating cardiac myocytes. SVCs were isolated from the stromal vascular fraction of murine adipose tissue. Cells were cultured in methylcellulose-based murine stem cell media. Analysis of SVC-derived beating myocytes included Western blot and calcium imaging. Enrichment of acutely isolated SVCs was carried out using antibody-tagged magnetic nanoparticles, and pharmacologic manipulation of Wnt and cytokine signaling. Under initial media conditions, spontaneously beating SVCs expressed both cardiac developmental and adult protein isoforms. Functionally, this specialized population can spontaneously contract and pace under field stimulation and shows the presence of coordinated calcium transients. Importantly, this study provides evidence for two independent mechanisms of enriching the cardiac differentiation of SVCs. First, this study shows that differentiation of SVCs into cardiac myocytes is augmented by non-canonical Wnt agonists, canonical Wnt antagonists, and cytokines. Second, SVCs capable of cardiac lineage differentiation can be enriched by selection for stem cell-specific membrane markers Sca1 and c-kit. Adipose-derived SVCs are a unique population of stem cells that show evidence of cardiac lineage development making them a potential source for stem cell-based cardiac regeneration studies.

  16. Evaluating MRI based vascular wall motion as a biomarker of Fontan hemodynamic performance

    NASA Astrophysics Data System (ADS)

    Menon, Prahlad G.; Hong, Haifa

    2015-03-01

    The Fontan procedure for single-ventricle heart disease involves creation of pathways to divert venous blood from the superior & inferior venacavae (SVC, IVC) directly into the pulmonary arteries (PA), bypassing the right ventricle. For optimal surgical outcomes, venous flow energy loss in the resulting vascular construction must be minimized and ensuring close to equal flow distribution from the Fontan conduit connecting IVC to the left & right PA is paramount. This requires patient-specific hemodynamic evaluation using computational fluid dynamics (CFD) simulations which are often time and resource intensive, limiting applicability for real-time patient management in the clinic. In this study, we report preliminary efforts at identifying a new non-invasive imaging based surrogate for CFD simulated hemodynamics. We establish correlations between computed hemodynamic criteria from CFD modeling and cumulative wall displacement characteristics of the Fontan conduit quantified from cine cardiovascular MRI segmentations over time (i.e. 20 cardiac phases gated from the start of ventricular systole), in 5 unique Fontan surgical connections. To focus our attention on diameter variations while discounting side-to-side swaying motion of the Fontan conduit, the difference between its instantaneous regional expansion and inward contraction (averaged across the conduit) was computed and analyzed. Maximum Fontan conduit-average expansion over the cardiac cycle correlated with the anatomy-specific diametric offset between the axis of the IVC and SVC (r2=0.13, p=0.55) - a known factor correlated with Fontan energy loss and IVC-to-PA flow distribution. Investigation in a larger study cohort is needed to establish stronger statistical correlations.

  17. Non-canonical Wnt Signaling Enhances differentiation of Sca1+/c-kit+ Adipose-derived Murine Stromal Vascular Cells into Spontaneously Beating Cardiac Myocytes

    PubMed Central

    Palpant, Nathan J.; Yasuda, So-ichiro; MacDougald, Ormond; Metzger, Joseph M.

    2007-01-01

    Recent reports have described a stem cell population termed stromal vascular cells (SVCs) derived from the stromal vascular fraction of adipose tissue, which are capable of intrinsic differentiation into spontaneously beating cardiomyocytes in vitro. The objective of this study was to further define the cardiac lineage differentiation potential of SVCs in vitro and to derive methods for enriching SVC-derived beating cardiac myocytes. SVCs were isolated from the stromal vascular fraction of murine adipose tissue. Cells were cultured in methylcellulose-based murine stem cell media. Analysis of SVC-derived beating myocytes included Western blot, and calcium imaging. Enrichment of acutely isolated SVCs was carried out using antibody tagged magnetic nanoparticles, and pharmacologic manipulation of Wnt and cytokine signaling. Under initial media conditions, spontaneously beating SVCs expressed both cardiac developmental and adult protein isoforms. Functionally, this specialized population can spontaneously contract and pace under field stimulation, and shows the presence of coordinated calcium transients. Importantly, this study provides evidence for two independent mechanisms of enriching the cardiac differentiation of SVCs. First, this study shows that differentiation of SVCs into cardiac myocytes is augmented by non-canonical Wnt agonists, canonical Wnt antagonists, and cytokines. Second, SVCs capable of cardiac lineage differentiation can be enriched by selection for stem cell-specific membrane markers Sca1 and c-kit. Adipose-derived SVCs are a unique population of stem cells that show evidence of cardiac lineage development making them a potential source for stem cell-based cardiac regeneration studies. PMID:17706246

  18. Radiative transfer code SHARM-3D for radiance simulations over a non-Lambertian nonhomogeneous surface: intercomparison study.

    PubMed

    Lyapustin, Alexei

    2002-09-20

    Results of an extensive validation study of the new radiative transfer code SHARM-3D are described. The code is designed for modeling of unpolarized monochromatic radiative transfer in the visible and near-IR spectra in the laterally uniform atmosphere over an arbitrarily inhomogeneous anisotropic surface. The surface boundary condition is periodic. The algorithm is based on an exact solution derived with the Green's function method. Several parameterizations were introduced into the algorithm to achieve superior performance. As a result, SHARM-3D is 2-3 orders of magnitude faster than the rigorous code SHDOM. It can model radiances over large surface scenes for a number of incidence-view geometries simultaneously. Extensive comparisons against SHDOM indicate that SHARM-3D has an average accuracy of better than 1%, which along with the high speed of calculations makes it a unique tool for remote-sensing applications in land surface and related atmospheric radiation studies.

  19. Radiative Transfer Code SHARM-3D for Radiance Simulations over a non-Lambertian Nonhomogeneous Surface: Intercomparison Study

    NASA Astrophysics Data System (ADS)

    Lyapustin, Alexei

    2002-09-01

    Results of an extensive validation study of the new radiative transfer code SHARM-3D are described. The code is designed for modeling of unpolarized monochromatic radiative transfer in the visible and near-IR spectra in the laterally uniform atmosphere over an arbitrarily inhomogeneous anisotropic surface. The surface boundary condition is periodic. The algorithm is based on an exact solution derived with the Green ’s function method. Several parameterizations were introduced into the algorithm to achieve superior performance. As a result, SHARM-3D is 2 -3 orders of magnitude faster than the rigorous code SHDOM. It can model radiances over large surface scenes for a number of incidence-view geometries simultaneously. Extensive comparisons against SHDOM indicate that SHARM-3D has an average accuracy of better than 1%, which along with the high speed of calculations makes it a unique tool for remote-sensing applications in land surface and related atmospheric radiation studies.

  20. The Particle Accelerator Simulation Code PyORBIT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorlov, Timofey V; Holmes, Jeffrey A; Cousineau, Sarah M

    2015-01-01

    The particle accelerator simulation code PyORBIT is presented. The structure, implementation, history, parallel and simulation capabilities, and future development of the code are discussed. The PyORBIT code is a new implementation and extension of algorithms of the original ORBIT code that was developed for the Spallation Neutron Source accelerator at the Oak Ridge National Laboratory. The PyORBIT code has a two level structure. The upper level uses the Python programming language to control the flow of intensive calculations performed by the lower level code implemented in the C++ language. The parallel capabilities are based on MPI communications. The PyORBIT ismore » an open source code accessible to the public through the Google Open Source Projects Hosting service.« less

  1. Trace-shortened Reed-Solomon codes

    NASA Technical Reports Server (NTRS)

    Mceliece, R. J.; Solomon, G.

    1994-01-01

    Reed-Solomon (RS) codes have been part of standard NASA telecommunications systems for many years. RS codes are character-oriented error-correcting codes, and their principal use in space applications has been as outer codes in concatenated coding systems. However, for a given character size, say m bits, RS codes are limited to a length of, at most, 2(exp m). It is known in theory that longer character-oriented codes would be superior to RS codes in concatenation applications, but until recently no practical class of 'long' character-oriented codes had been discovered. In 1992, however, Solomon discovered an extensive class of such codes, which are now called trace-shortened Reed-Solomon (TSRS) codes. In this article, we will continue the study of TSRS codes. Our main result is a formula for the dimension of any TSRS code, as a function of its error-correcting power. Using this formula, we will give several examples of TSRS codes, some of which look very promising as candidate outer codes in high-performance coded telecommunications systems.

  2. A Deterministic Transport Code for Space Environment Electrons

    NASA Technical Reports Server (NTRS)

    Nealy, John E.; Chang, C. K.; Norman, Ryan B.; Blattnig, Steve R.; Badavi, Francis F.; Adamczyk, Anne M.

    2010-01-01

    A deterministic computational procedure has been developed to describe transport of space environment electrons in various shield media. This code is an upgrade and extension of an earlier electron code. Whereas the former code was formulated on the basis of parametric functions derived from limited laboratory data, the present code utilizes well established theoretical representations to describe the relevant interactions and transport processes. The shield material specification has been made more general, as have the pertinent cross sections. A combined mean free path and average trajectory approach has been used in the transport formalism. Comparisons with Monte Carlo calculations are presented.

  3. Finite element analysis of inviscid subsonic boattail flow

    NASA Technical Reports Server (NTRS)

    Chima, R. V.; Gerhart, P. M.

    1981-01-01

    A finite element code for analysis of inviscid subsonic flows over arbitrary nonlifting planar or axisymmetric bodies is described. The code solves a novel primitive variable formulation of the coupled irrotationality and compressible continuity equations. Results for flow over a cylinder, a sphere, and a NACA 0012 airfoil verify the code. Computed subcritical flows over an axisymmetric boattailed afterbody compare well with finite difference results and experimental data. Interative coupling with an integral turbulent boundary layer code shows strong viscous effects on the inviscid flow. Improvements in code efficiency and extensions to transonic flows are discussed.

  4. Enhanced 2/3 four-ary modulation code using soft-decision Viterbi decoding for four-level holographic data storage systems

    NASA Astrophysics Data System (ADS)

    Kong, Gyuyeol; Choi, Sooyong

    2017-09-01

    An enhanced 2/3 four-ary modulation code using soft-decision Viterbi decoding is proposed for four-level holographic data storage systems. While the previous four-ary modulation codes focus on preventing maximum two-dimensional intersymbol interference patterns, the proposed four-ary modulation code aims at maximizing the coding gains for better bit error rate performances. For achieving significant coding gains from the four-ary modulation codes, we design a new 2/3 four-ary modulation code in order to enlarge the free distance on the trellis through extensive simulation. The free distance of the proposed four-ary modulation code is extended from 1.21 to 2.04 compared with that of the conventional four-ary modulation code. The simulation result shows that the proposed four-ary modulation code has more than 1 dB gains compared with the conventional four-ary modulation code.

  5. Algorithm and code development for unsteady three-dimensional Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Obayashi, Shigeru

    1994-01-01

    Aeroelastic tests require extensive cost and risk. An aeroelastic wind-tunnel experiment is an order of magnitude more expensive than a parallel experiment involving only aerodynamics. By complementing the wind-tunnel experiments with numerical simulations, the overall cost of the development of aircraft can be considerably reduced. In order to accurately compute aeroelastic phenomenon it is necessary to solve the unsteady Euler/Navier-Stokes equations simultaneously with the structural equations of motion. These equations accurately describe the flow phenomena for aeroelastic applications. At ARC a code, ENSAERO, is being developed for computing the unsteady aerodynamics and aeroelasticity of aircraft, and it solves the Euler/Navier-Stokes equations. The purpose of this cooperative agreement was to enhance ENSAERO in both algorithm and geometric capabilities. During the last five years, the algorithms of the code have been enhanced extensively by using high-resolution upwind algorithms and efficient implicit solvers. The zonal capability of the code has been extended from a one-to-one grid interface to a mismatching unsteady zonal interface. The geometric capability of the code has been extended from a single oscillating wing case to a full-span wing-body configuration with oscillating control surfaces. Each time a new capability was added, a proper validation case was simulated, and the capability of the code was demonstrated.

  6. Nonambipolar Transport and Torque in Perturbed Equilibria

    NASA Astrophysics Data System (ADS)

    Logan, N. C.; Park, J.-K.; Wang, Z. R.; Berkery, J. W.; Kim, K.; Menard, J. E.

    2013-10-01

    A new Perturbed Equilibrium Nonambipolar Transport (PENT) code has been developed to calculate the neoclassical toroidal torque from radial current composed of both passing and trapped particles in perturbed equilibria. This presentation outlines the physics approach used in the development of the PENT code, with emphasis on the effects of retaining general aspect-ratio geometric effects. First, nonambipolar transport coefficients and corresponding neoclassical toroidal viscous (NTV) torque in perturbed equilibria are re-derived from the first order gyro-drift-kinetic equation in the ``combined-NTV'' PENT formalism. The equivalence of NTV torque and change in potential energy due to kinetic effects [J-K. Park, Phys. Plas., 2011] is then used to showcase computational challenges shared between PENT and stability codes MISK and MARS-K. Extensive comparisons to a reduced model, which makes numerous large aspect ratio approximations, are used throughout to emphasize geometry dependent physics such as pitch angle resonances. These applications make extensive use of the PENT code's native interfacing with the Ideal Perturbed Equilibrium Code (IPEC), and the combination of these codes is a key step towards an iterative solver for self-consistent perturbed equilibrium torque. Supported by US DOE contract #DE-AC02-09CH11466 and the DOE Office of Science Graduate Fellowship administered by the Oak Ridge Institute for Science & Education under contract #DE-AC05-06OR23100.

  7. HEPMath 1.4: A mathematica package for semi-automatic computations in high energy physics

    NASA Astrophysics Data System (ADS)

    Wiebusch, Martin

    2015-10-01

    This article introduces the Mathematica package HEPMath which provides a number of utilities and algorithms for High Energy Physics computations in Mathematica. Its functionality is similar to packages like FormCalc or FeynCalc, but it takes a more complete and extensible approach to implementing common High Energy Physics notations in the Mathematica language, in particular those related to tensors and index contractions. It also provides a more flexible method for the generation of numerical code which is based on new features for C code generation in Mathematica. In particular it can automatically generate Python extension modules which make the compiled functions callable from Python, thus eliminating the need to write any code in a low-level language like C or Fortran. It also contains seamless interfaces to LHAPDF, FeynArts, and LoopTools.

  8. 77 FR 16022 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-19

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Agency Information Collection Extension AGENCY: Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy... Renewable Energy. [FR Doc. 2012-6546 Filed 3-16-12; 8:45 am] BILLING CODE 6450-01-P ...

  9. 76 FR 37372 - Notice of Proposed Withdrawal Extension and Notification of a Public Meeting; Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-27

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [61510-8451-0000; MTM 80092] Notice of Proposed Withdrawal Extension and Notification of a Public Meeting; Montana AGENCY: Bureau of Land...; 8:45 am] BILLING CODE 4310-55-P ...

  10. Progressive Dictionary Learning with Hierarchical Predictive Structure for Scalable Video Coding.

    PubMed

    Dai, Wenrui; Shen, Yangmei; Xiong, Hongkai; Jiang, Xiaoqian; Zou, Junni; Taubman, David

    2017-04-12

    Dictionary learning has emerged as a promising alternative to the conventional hybrid coding framework. However, the rigid structure of sequential training and prediction degrades its performance in scalable video coding. This paper proposes a progressive dictionary learning framework with hierarchical predictive structure for scalable video coding, especially in low bitrate region. For pyramidal layers, sparse representation based on spatio-temporal dictionary is adopted to improve the coding efficiency of enhancement layers (ELs) with a guarantee of reconstruction performance. The overcomplete dictionary is trained to adaptively capture local structures along motion trajectories as well as exploit the correlations between neighboring layers of resolutions. Furthermore, progressive dictionary learning is developed to enable the scalability in temporal domain and restrict the error propagation in a close-loop predictor. Under the hierarchical predictive structure, online learning is leveraged to guarantee the training and prediction performance with an improved convergence rate. To accommodate with the stateof- the-art scalable extension of H.264/AVC and latest HEVC, standardized codec cores are utilized to encode the base and enhancement layers. Experimental results show that the proposed method outperforms the latest SHVC and HEVC simulcast over extensive test sequences with various resolutions.

  11. Digital Coding and the Self-Proving Message

    ERIC Educational Resources Information Center

    Dettering, Richard

    1971-01-01

    Author suggests that digital Communication", which relies on arbitrary coding elements, like the phones of speech," overshadows the importance of the analogic symbolism people use more extensively than realized. Non-verbal messages can be more convincing than verbal and can be used to predict patterns of future behavior. (Author/PD)

  12. SVC obstruction and stridor relieved by nasogastric tube insertion

    PubMed Central

    Molena, Emma J.; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-01-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. PMID:26933001

  13. Lightweight computational steering of very large scale molecular dynamics simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beazley, D.M.; Lomdahl, P.S.

    1996-09-01

    We present a computational steering approach for controlling, analyzing, and visualizing very large scale molecular dynamics simulations involving tens to hundreds of millions of atoms. Our approach relies on extensible scripting languages and an easy to use tool for building extensions and modules. The system is extremely easy to modify, works with existing C code, is memory efficient, and can be used from inexpensive workstations and networks. We demonstrate how we have used this system to manipulate data from production MD simulations involving as many as 104 million atoms running on the CM-5 and Cray T3D. We also show howmore » this approach can be used to build systems that integrate common scripting languages (including Tcl/Tk, Perl, and Python), simulation code, user extensions, and commercial data analysis packages.« less

  14. 75 FR 15693 - Extension of Web-Based TRICARE Assistance Program Demonstration Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary Extension of Web-Based TRICARE Assistance Program Demonstration Project AGENCY: Department of Defense (DoD). ACTION: Notice of a Web-Based TRICARE Assistance... States Code, Section 1092, entitled Web-Based TRICARE Assistance Program. This demonstration was...

  15. Extensions and Adjuncts to the BRL-COMGEOM Program

    DTIC Science & Technology

    1974-08-01

    m MAGIC Code, GIFT Code, Computer Simulation, Target Description, Geometric Modeling Techniques, Vulnerability Analysis 20...Arbitrary Quadric Surf ace.. 0Oo „<>. 7 III. BRITL: A GEOMETRY PREPROCESSOR PROGRAM FOR INPUT TO THE GIFT SYSTEM „ 0 18 A. Introduction <, „. ° 18 B...the BRL- GIFT code. The tasks completed under this contract and described in the report are: Ao The addition to the list of available body types

  16. Coding conventions and principles for a National Land-Change Modeling Framework

    USGS Publications Warehouse

    Donato, David I.

    2017-07-14

    This report establishes specific rules for writing computer source code for use with the National Land-Change Modeling Framework (NLCMF). These specific rules consist of conventions and principles for writing code primarily in the C and C++ programming languages. Collectively, these coding conventions and coding principles create an NLCMF programming style. In addition to detailed naming conventions, this report provides general coding conventions and principles intended to facilitate the development of high-performance software implemented with code that is extensible, flexible, and interoperable. Conventions for developing modular code are explained in general terms and also enabled and demonstrated through the appended templates for C++ base source-code and header files. The NLCMF limited-extern approach to module structure, code inclusion, and cross-module access to data is both explained in the text and then illustrated through the module templates. Advice on the use of global variables is provided.

  17. Low-density parity-check codes for volume holographic memory systems.

    PubMed

    Pishro-Nik, Hossein; Rahnavard, Nazanin; Ha, Jeongseok; Fekri, Faramarz; Adibi, Ali

    2003-02-10

    We investigate the application of low-density parity-check (LDPC) codes in volume holographic memory (VHM) systems. We show that a carefully designed irregular LDPC code has a very good performance in VHM systems. We optimize high-rate LDPC codes for the nonuniform error pattern in holographic memories to reduce the bit error rate extensively. The prior knowledge of noise distribution is used for designing as well as decoding the LDPC codes. We show that these codes have a superior performance to that of Reed-Solomon (RS) codes and regular LDPC counterparts. Our simulation shows that we can increase the maximum storage capacity of holographic memories by more than 50 percent if we use irregular LDPC codes with soft-decision decoding instead of conventionally employed RS codes with hard-decision decoding. The performance of these LDPC codes is close to the information theoretic capacity.

  18. Application of Chimera Navier-Stokes Code for High Speed Flows

    NASA Technical Reports Server (NTRS)

    Ajmani, Kumud

    1997-01-01

    The primary task for this year was performed in support of the "Trailblazer" project. The purpose of the task was to perform an extensive CFD study of the shock boundary-layer interaction between the engine-diverters and the primary body surfaces of the Trailblazer vehicle. Information gathered from this study would be used to determine the effectiveness of the diverters in preventing the boundary-layer coming off of the vehicle forebody from entering the main engines. The PEGSUS code was used to define the "holes" and "boundaries" for each grid. Two sets of CFD calculations were performed.Extensive post-processing of the results was performed.

  19. Confined Turbulent Swirling Recirculating Flow Predictions. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Abujelala, M. T.

    1984-01-01

    Turbulent swirling flow, the STARPIC computer code, turbulence modeling of turbulent flows, the k-xi turbulence model and extensions, turbulence parameters deduction from swirling confined flow measurements, extension of the k-xi to confined swirling recirculating flows, and general predictions for confined turbulent swirling flow are discussed.

  20. 78 FR 73915 - Notice of Request for Extension of Currently Approved Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-09

    ..., Enterprise Information Security & Policy. [FR Doc. 2013-29218 Filed 12-6-13; 8:45 am] BILLING CODE 8120-08-P ... TENNESSEE VALLEY AUTHORITY Notice of Request for Extension of Currently Approved Information... Currently Approved Information Collection. SUMMARY: The information collection described below will be...

  1. 75 FR 63856 - Public Land Order No. 7753; Extension of Public Land Order No. 7464; Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMTL06000-L14300000.ET0000; MTM 89170] Public Land Order No. 7753; Extension of Public Land Order No. 7464; Montana AGENCY: Bureau of Land...:45 am] BILLING CODE 4310-DN-P ...

  2. Extensive Air Showers in the Classroom

    ERIC Educational Resources Information Center

    Badala, A.; Blanco, F.; La Rocca, P.; Pappalardo, G. S.; Pulvirenti, A.; Riggi, F.

    2007-01-01

    The basic properties of extensive air showers of particles produced in the interaction of a high-energy primary cosmic ray in the Earth's atmosphere are discussed in the context of educational cosmic ray projects involving undergraduate students and high-school teams. Simulation results produced by an air shower development code were made…

  3. For Whom Is a Picture Worth a Thousand Words? Extensions of a Dual-Coding Theory of Multimedia Learning.

    ERIC Educational Resources Information Center

    Mayer, Richard E.; Sims, Valerie K.

    1994-01-01

    In 2 experiments, 162 high- and low-spatial ability students viewed a computer-generated animation and heard a concurrent or successive explanation. The concurrent group generated more creative solutions to transfer problems and demonstrated a contiguity effect consistent with dual-coding theory. (SLD)

  4. VS30 – A site-characterization parameter for use in building Codes, simplified earthquake resistant design, GMPEs, and ShakeMaps

    USGS Publications Warehouse

    Borcherdt, Roger D.

    2012-01-01

    VS30, defined as the average seismic shear-wave velocity from the surface to a depth of 30 meters, has found wide-spread use as a parameter to characterize site response for simplified earthquake resistant design as implemented in building codes worldwide. VS30 , as initially introduced by the author for the US 1994 NEHRP Building Code, provides unambiguous definitions of site classes and site coefficients for site-dependent response spectra based on correlations derived from extensive borehole logging and comparative ground-motion measurement programs in California. Subsequent use of VS30 for development of strong ground motion prediction equations (GMPEs) and measurement of extensive sets of VS borehole data have confirmed the previous empirical correlations and established correlations of SVS30 with VSZ at other depths. These correlations provide closed form expressions to predict S30 V at a large number of additional sites and further justify S30 V as a parameter to characterize site response for simplified building codes, GMPEs, ShakeMap, and seismic hazard mapping.

  5. Parallel CARLOS-3D code development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Putnam, J.M.; Kotulski, J.D.

    1996-02-01

    CARLOS-3D is a three-dimensional scattering code which was developed under the sponsorship of the Electromagnetic Code Consortium, and is currently used by over 80 aerospace companies and government agencies. The code has been extensively validated and runs on both serial workstations and parallel super computers such as the Intel Paragon. CARLOS-3D is a three-dimensional surface integral equation scattering code based on a Galerkin method of moments formulation employing Rao- Wilton-Glisson roof-top basis for triangular faceted surfaces. Fully arbitrary 3D geometries composed of multiple conducting and homogeneous bulk dielectric materials can be modeled. This presentation describes some of the extensions tomore » the CARLOS-3D code, and how the operator structure of the code facilitated these improvements. Body of revolution (BOR) and two-dimensional geometries were incorporated by simply including new input routines, and the appropriate Galerkin matrix operator routines. Some additional modifications were required in the combined field integral equation matrix generation routine due to the symmetric nature of the BOR and 2D operators. Quadrilateral patched surfaces with linear roof-top basis functions were also implemented in the same manner. Quadrilateral facets and triangular facets can be used in combination to more efficiently model geometries with both large smooth surfaces and surfaces with fine detail such as gaps and cracks. Since the parallel implementation in CARLOS-3D is at high level, these changes were independent of the computer platform being used. This approach minimizes code maintenance, while providing capabilities with little additional effort. Results are presented showing the performance and accuracy of the code for some large scattering problems. Comparisons between triangular faceted and quadrilateral faceted geometry representations will be shown for some complex scatterers.« less

  6. Error suppression via complementary gauge choices in Reed-Muller codes

    NASA Astrophysics Data System (ADS)

    Chamberland, Christopher; Jochym-O'Connor, Tomas

    2017-09-01

    Concatenation of two quantum error-correcting codes with complementary sets of transversal gates can provide a means toward universal fault-tolerant quantum computation. We first show that it is generally preferable to choose the inner code with the higher pseudo-threshold to achieve lower logical failure rates. We then explore the threshold properties of a wide range of concatenation schemes. Notably, we demonstrate that the concatenation of complementary sets of Reed-Muller codes can increase the code capacity threshold under depolarizing noise when compared to extensions of previously proposed concatenation models. We also analyze the properties of logical errors under circuit-level noise, showing that smaller codes perform better for all sampled physical error rates. Our work provides new insights into the performance of universal concatenated quantum codes for both code capacity and circuit-level noise.

  7. Mode-dependent templates and scan order for H.264/AVC-based intra lossless coding.

    PubMed

    Gu, Zhouye; Lin, Weisi; Lee, Bu-Sung; Lau, Chiew Tong; Sun, Ming-Ting

    2012-09-01

    In H.264/advanced video coding (AVC), lossless coding and lossy coding share the same entropy coding module. However, the entropy coders in the H.264/AVC standard were original designed for lossy video coding and do not yield adequate performance for lossless video coding. In this paper, we analyze the problem with the current lossless coding scheme and propose a mode-dependent template (MD-template) based method for intra lossless coding. By exploring the statistical redundancy of the prediction residual in the H.264/AVC intra prediction modes, more zero coefficients are generated. By designing a new scan order for each MD-template, the scanned coefficients sequence fits the H.264/AVC entropy coders better. A fast implementation algorithm is also designed. With little computation increase, experimental results confirm that the proposed fast algorithm achieves about 7.2% bit saving compared with the current H.264/AVC fidelity range extensions high profile.

  8. SYMTRAN - A Time-dependent Symmetric Tandem Mirror Transport Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, D; Fowler, T

    2004-06-15

    A time-dependent version of the steady-state radial transport model in symmetric tandem mirrors in Ref. [1] has been coded up and first tests performed. Our code, named SYMTRAN, is an adaptation of the earlier SPHERE code for spheromaks, now modified for tandem mirror physics. Motivated by Post's new concept of kinetic stabilization of symmetric mirrors, it is an extension of the earlier TAMRAC rate-equation code omitting radial transport [2], which successfully accounted for experimental results in TMX. The SYMTRAN code differs from the earlier tandem mirror radial transport code TMT in that our code is focused on axisymmetric tandem mirrorsmore » and classical diffusion, whereas TMT emphasized non-ambipolar transport in TMX and MFTF-B due to yin-yang plugs and non-symmetric transitions between the plugs and axisymmetric center cell. Both codes exhibit interesting but different non-linear behavior.« less

  9. Real-Time MRI-Guided Cardiac Cryo-Ablation: A Feasibility Study.

    PubMed

    Kholmovski, Eugene G; Coulombe, Nicolas; Silvernagel, Joshua; Angel, Nathan; Parker, Dennis; Macleod, Rob; Marrouche, Nassir; Ranjan, Ravi

    2016-05-01

    MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system. Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner. The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination. This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage. © 2016 Wiley Periodicals, Inc.

  10. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study.

    PubMed

    Seed, Mike; van Amerom, Joshua F P; Yoo, Shi-Joon; Al Nafisi, Bahiyah; Grosse-Wortmann, Lars; Jaeggi, Edgar; Jansz, Michael S; Macgowan, Christopher K

    2012-11-26

    We present the first phase contrast (PC) cardiovascular magnetic resonance (CMR) measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG). A validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30-39 weeks). Flow was measured in the major fetal vessels and indexed to the fetal weight. There was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96). Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO) 540 ± 101, main pulmonary artery (MPA) 327 ± 68, ascending aorta (AAo) 198 ± 38, superior vena cava (SVC) 147 ± 46, ductus arteriosus (DA) 220 ± 39,pulmonary blood flow (PBF) 106 ± 59,descending aorta (DAo) 273 ± 85, umbilical vein (UV) 160 ± 62, foramen ovale (FO)107 ± 54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60 ± 4, AAo37 ± 4, SVC 28 ± 7, DA 41 ± 8, PBF 19 ± 10, DAo50 ± 12, UV 30 ± 9, FO 21 ± 12. This study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.

  11. Effects of Occupational Noise Exposure on 24-Hour Ambulatory Vascular Properties in Male Workers

    PubMed Central

    Chang, Ta-Yuan; Su, Ta-Chen; Lin, Shou-Yu; Jain, Ruei-Man; Chan, Chang-Chuan

    2007-01-01

    Background Epidemiologic studies have demonstrated that occupational noise exposure is associated with hypertension, but the related mechanism in vascular structural changes is unclear. Objective This panel study aimed to investigate effects of occupational noise exposure on ambulatory vascular structural properties in male workers. Methods We recruited 20 volunteers and divided them into a high-noise–exposure group of 15 and a low-noise–exposure group of 5 based on environmental noise measurement in an automobile manufacturing company. We determined individual noise exposure and measured personal ambulatory vascular property parameters simultaneously during 24 hr. Linear mixed-effects regression models were used to estimate transient and sustained effects of noise exposure on vascular parameters by adjusting some confounders collected from self-administrated questionnaires and health checkups. Results The high-noise–exposed (85 ± 8 dBA) workers had significantly higher systemic vascular resistance (SVR) than the low-noise–exposed workers (59 ± 4 dBA) during work and sleep periods. Contrarily, low-noise–exposed workers had significantly higher brachial artery compliance (BAC), brachial artery distensibility (BAD), and systemic vascular compliance (SVC; marginal, p = 0.07) than high-noise–exposed workers during off-duty periods. We also found that high-noise–exposed workers had significantly lower BAC (1.38 ± 0.55 %mL/mmHg) and BAD (1.29 ± 0.51 %/mmHg), as well as lower SVC (0.24 ± 0.10 mL/L/mmHg), but higher SVR (1.93 ± 0.67 mL/L/min) compared with low-noise–exposed workers over a 24-hr period. Conclusions Our findings suggest that in automobile workers, occupational noise exposure may have sustained, not transient, effects on vascular properties and also enhances the development of hypertension. PMID:18008000

  12. Strict sequential catheter ablation strategy targeting the pulmonary veins and superior vena cava for persistent atrial fibrillation.

    PubMed

    Yoshiga, Yasuhiro; Shimizu, Akihiko; Ueyama, Takeshi; Ono, Makoto; Fukuda, Masakazu; Fumimoto, Tomoko; Ishiguchi, Hironori; Omuro, Takuya; Kobayashi, Shigeki; Yano, Masafumi

    2018-08-01

    An effective catheter ablation strategy, beyond pulmonary vein isolation (PVI), for persistent atrial fibrillation (AF) is necessary. Pulmonary vein (PV)-reconduction also causes recurrent atrial tachyarrhythmias. The effect of the PVI and additional effect of a superior vena cava (SVC) isolation (SVCI) was strictly evaluated. Seventy consecutive patients with persistent AF who underwent a strict sequential ablation strategy targeting the PVs and SVC were included in this study. The initial ablation strategy was a circumferential PVI. A segmental SVCI was only applied as a repeat procedure when patients demonstrated no PV-reconduction. After the initial procedure, persistent AF was suppressed in 39 of 70 (55.7%) patients during a median follow-up of 32 months. After multiple procedures, persistent AF was suppressed in 46 (65.7%) and 52 (74.3%) patients after receiving the PVI alone and PVI plus SVCI strategies, respectively. In 6 of 15 (40.0%) patients with persistent AF resistant to PVI, persistent AF was suppressed. The persistent AF duration independently predicted persistent AF recurrences after multiple PVI alone procedures [HR: 1.012 (95% confidence interval: 1.006-1.018); p<0.001] and PVI plus SVCI strategies [HR: 1.018 (95% confidence interval: 1.011-1.025); p<0.001]. A receiver-operating-characteristic analysis for recurrent persistent AF indicated an optimal cut-off value of 20 and 32 months for the persistent AF duration using the PVI alone and PVI plus SVCI strategies, respectively. The outcomes of the PVI plus SVCI strategy were favorable for patients with shorter persistent AF durations. The initial SVCI had the additional effect of maintaining sinus rhythm in some patients with persistent AF resistant to PVI. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  13. Habitat complexity and fish size affect the detection of Indo-Pacific lionfish on invaded coral reefs

    NASA Astrophysics Data System (ADS)

    Green, S. J.; Tamburello, N.; Miller, S. E.; Akins, J. L.; Côté, I. M.

    2013-06-01

    A standard approach to improving the accuracy of reef fish population estimates derived from underwater visual censuses (UVCs) is the application of species-specific correction factors, which assumes that a species' detectability is constant under all conditions. To test this assumption, we quantified detection rates for invasive Indo-Pacific lionfish ( Pterois volitans and P. miles), which are now a primary threat to coral reef conservation throughout the Caribbean. Estimates of lionfish population density and distribution, which are essential for managing the invasion, are currently obtained through standard UVCs. Using two conventional UVC methods, the belt transect and stationary visual census (SVC), we assessed how lionfish detection rates vary with lionfish body size and habitat complexity (measured as rugosity) on invaded continuous and patch reefs off Cape Eleuthera, the Bahamas. Belt transect and SVC surveys performed equally poorly, with both methods failing to detect the presence of lionfish in >50 % of surveys where thorough, lionfish-focussed searches yielded one or more individuals. Conventional methods underestimated lionfish biomass by ~200 %. Crucially, detection rate varied significantly with both lionfish size and reef rugosity, indicating that the application of a single correction factor across habitats and stages of invasion is unlikely to accurately characterize local populations. Applying variable correction factors that account for site-specific lionfish size and rugosity to conventional survey data increased estimates of lionfish biomass, but these remained significantly lower than actual biomass. To increase the accuracy and reliability of estimates of lionfish density and distribution, monitoring programs should use detailed area searches rather than standard visual survey methods. Our study highlights the importance of accounting for sources of spatial and temporal variation in detection to increase the accuracy of survey data from coral reef systems.

  14. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    PubMed

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  15. Laboratory Simulations and Spectral Analyses of Space Weathering of Non-Ice Materials on Ocean Worlds

    NASA Astrophysics Data System (ADS)

    Wing, B. R.; Shusterman, M. L.; Irvin, B. L.; Hibbitts, C.

    2016-12-01

    Airless solar system bodies are subjected to bombardment by high-energy particles from the solar wind and for Galilean satellites, from the Jovian magnetosphere. These keV-MeV electrons and ions damage the upper microns of the exposed surface, resulting in physical, chemical, and spectral alterations that may confound interpretations of mineralogical properties. We conducted experiments simulating space weathering by energetic electrons for characterizing the spectral effects from the UV through the mid-IR; wavelengths commonly used to determine compositions of airless bodies. We bombarded analog non-ice materials with 40 keV electrons under high vacuum conditions for a period of 48-96 hours at a fluence of 80 μA. Spectral measurements were obtained at UV, VIS-SWIR, and NIR-MIR ranges from 0.14-5.0 μm using a McPherson 302 monochrometer, an SVC fiber-fed point spectrometer, and a Bruker Vertex 70 FTIR, respectively. The monochrometer and FTIR measurements were obtained before, during, and after irradiation, while the sample was under vacuum at 1e-7 torr. SVC measurements were obtained in a separate apparatus under an N2-purged environment before and after irradiation. The experiments were conducted to develop a better understanding of how exposure to particulate bombardment may affect the spectral features of airless bodies and subsequent interpretation of composition. Our results characterize the spectral nature of radiation-induced color centers, or Farbe-centers, that are active in the NUV-VIS-NIR wavelength range and inactive in the SWIR-MIR wavelength range. We confirmed the discoloration is due to the formation of F-centers rather than trace contamination such as iron, by analyzing samples under scanning electron microscope and X-ray spectrometer.

  16. Bidirectional superior cavopulmonary anastomosis with or without cardiopulmonary bypass: A randomized study.

    PubMed

    Talwar, Sachin; Gupta, Anish; Nehra, Ashima; Makhija, Neeti; Kapoor, Poonam Malhotra; Sreenivas, Vishnubhatla; Choudhary, Shiv Kumar; Airan, Balram

    2017-06-01

    This study aims to compare the bidirectional superior cavopulmonary anastomosis (BDG) with or without cardiopulmonary bypass (CPB). 100 patients undergoing BDG were randomized into two groups: Off-CPB or on-CPB groups. All patients underwent near-infrared spectrophotometry (NIRS) and bispectral index (BIS) monitoring and pre- and postoperative serum 100 beta protein measurements (Sβ100) and neuro-cognitive evaluation. Postoperative intensive care unit (ICU) parameters were also studied. The median age of patients in the on-CPB and off-CPB group were 42 and 48 months, respectively (p = 0.11). Median weights in the on-CPB group and off-CPB group were 13.5 (5-50) kg and 15 (7-36) kg, respectively (p = 0.927). There was a significant rise in superior vena cava (SVC) pressure on SVC clamping in the off-CPB group (23.12 ± 6.84 vs 2.98 ± 2.22 mmHg) on-CPB group (p < 0.001). There was a significant fall in NIRS and BIS values from baseline in the off-CPB group during the anastomosis but there was no statistically significant change in serum Sβ100from pre-clamp to post-clamp in either group. Inotropic support, duration of ventilation, ICU stay, and hospital stay were significantly less in the off-CPB group (p < 0.001). Assessment of Social Adaptive Functioning revealed no adverse sequelae. There were significant cost savings if surgery was performed off-CPB (p < 0.001). Off CPB-BDG is an economical and safe procedure. Duration of inotropic and mechanical ventilatory support, ICU, and hospital stay is significantly less. We did not observe any early adverse neurologic sequelae in patients undergoing off-CPB BDG. © 2017 Wiley Periodicals, Inc.

  17. Virtual reality lead extraction as a method for training new physicians: a pilot study.

    PubMed

    Maytin, Melanie; Daily, Thomas P; Carillo, Roger G

    2015-03-01

    It is estimated that the demand for transvenous lead extraction (TLE) has reached an annual extraction rate of nearly 24,000 patients worldwide. Despite technologic advances, TLE still has the potential for significant morbidity and mortality. Complication rates with TLE directly parallel operator experience. However, obtaining adequate training during and postfellowship can be difficult. Given the potential for catastrophic complications and the steep learning curve (up to 300 cases) associated with this procedure, we sought to validate a virtual reality (VR) lead extraction simulator as an innovative training and evaluation tool for physicians new to TLE. We randomized eight electrophysiology fellows to VR simulator versus conventional training. We compared procedural skill competency between the groups using simulator competency, tactile measurements, markers of proficiency and attitudes, and cognitive abilities battery. Practical skills and simulator complications differed significantly between the VR simulator and conventional training groups. The VR simulator group executed patient preparation and procedure performance better than the conventional group (P < 0.01). All four fellows randomized to conventional training experienced a simulator complication (two superior vena cava [SVC] tears, three right ventricle [RV] avulsions) versus one fellow in the VR simulator group (one SVC tear) (P = 0.02). Tactile measurements revealed a trend toward excess pushing versus pulling forces among the conventionally trained group. The time for lead removal was also significantly higher in the conventional training group (12.46 minutes vs 5.54 minutes, P = 0.02). There was no significant difference in baseline or posttraining cognitive ability. We contend that the implementation of alternative training tools such as a VR simulation model will improve physician training and allow for an innovative pathway to assess the achievement of competency. ©2014 Wiley Periodicals, Inc.

  18. Postoperative Structural Brain Changes and Cognitive Dysfunction in Patients with Breast Cancer.

    PubMed

    Sato, Chiho; Sekiguchi, Atsushi; Kawai, Masaaki; Kotozaki, Yuka; Nouchi, Rui; Tada, Hiroshi; Takeuchi, Hikaru; Ishida, Takanori; Taki, Yasuyuki; Kawashima, Ryuta; Ohuchi, Noriaki

    2015-01-01

    The primary purpose of this study was to clarify the influence of the early response to surgery on brain structure and cognitive function in patients with breast cancer. It was hypothesized that the structure of the thalamus would change during the early response after surgery due to the effects of anesthesia and would represent one aspect of an intermediate phenotype of postoperative cognitive dysfunction (POCD). We examined 32 postmenopausal females with breast cancer and 20 age-matched controls. We assessed their cognitive function (attention, memory, and executive function), and performed brain structural MRI 1.5 ± 0.5 days before and 5.6 ± 1.2 days after surgery. We found a significant interaction between regional grey matter volume (rGMV) in the thalamus (P < 0.05, familywise error (FWE), small volume correction (SVC)) and one attention domain subtest (P = 0.001, Bonferroni correction) after surgery in the patient group compared with the control group. Furthermore, the changes in attention were significantly associated with sevoflurane anesthetic dose (r2 = 0.247, β = ‒0.471, P = 0.032) and marginally associated with rGMV changes in the thalamus (P = 0.07, FWE, SVC) in the Pt group. Our findings suggest that alterations in brain structure, particularly in the thalamus, may occur shortly after surgery and may be associated with attentional dysfunction. This early postoperative response to anesthesia may represent an intermediate phenotype of POCD. It was assumed that patients experiencing other risk factors of POCD, such as the severity of surgery, the occurrence of complications, and pre-existing cognitive impairments, would develop clinical POCD with broad and multiple types of cognitive dysfunction.

  19. Using hidden Markov models and observed evolution to annotate viral genomes.

    PubMed

    McCauley, Stephen; Hein, Jotun

    2006-06-01

    ssRNA (single stranded) viral genomes are generally constrained in length and utilize overlapping reading frames to maximally exploit the coding potential within the genome length restrictions. This overlapping coding phenomenon leads to complex evolutionary constraints operating on the genome. In regions which code for more than one protein, silent mutations in one reading frame generally have a protein coding effect in another. To maximize coding flexibility in all reading frames, overlapping regions are often compositionally biased towards amino acids which are 6-fold degenerate with respect to the 64 codon alphabet. Previous methodologies have used this fact in an ad hoc manner to look for overlapping genes by motif matching. In this paper differentiated nucleotide compositional patterns in overlapping regions are incorporated into a probabilistic hidden Markov model (HMM) framework which is used to annotate ssRNA viral genomes. This work focuses on single sequence annotation and applies an HMM framework to ssRNA viral annotation. A description of how the HMM is parameterized, whilst annotating within a missing data framework is given. A Phylogenetic HMM (Phylo-HMM) extension, as applied to 14 aligned HIV2 sequences is also presented. This evolutionary extension serves as an illustration of the potential of the Phylo-HMM framework for ssRNA viral genomic annotation. The single sequence annotation procedure (SSA) is applied to 14 different strains of the HIV2 virus. Further results on alternative ssRNA viral genomes are presented to illustrate more generally the performance of the method. The results of the SSA method are encouraging however there is still room for improvement, and since there is overwhelming evidence to indicate that comparative methods can improve coding sequence (CDS) annotation, the SSA method is extended to a Phylo-HMM to incorporate evolutionary information. The Phylo-HMM extension is applied to the same set of 14 HIV2 sequences which are pre-aligned. The performance improvement that results from including the evolutionary information in the analysis is illustrated.

  20. A Three-Dimensional Eulerian Code for Simulation of High-Speed Multimaterial Interactions

    DTIC Science & Technology

    2011-08-01

    PDE -based extension. The extension process is done on only the host cells on a particular processor. After extension the parallel communication is...condensation shocks, explosive debris transport, detonation in heterogeneous media and so on. In these flows complex interactions occur between the...A.22] and ijΩ is the spin tensor. The Jaumann derivative is used to ensure objectivity of the stress tensor with respect to rotation

  1. Extension of applicable neutron energy of DARWIN up to 1 GeV.

    PubMed

    Satoh, D; Sato, T; Endo, A; Matsufuji, N; Takada, M

    2007-01-01

    The radiation-dose monitor, DARWIN, needs a set of response functions of the liquid organic scintillator to assess a neutron dose. SCINFUL-QMD is a Monte Carlo based computer code to evaluate the response functions. In order to improve the accuracy of the code, a new light-output function based on the experimental data was developed for the production and transport of protons deuterons, tritons, (3)He nuclei and alpha particles, and incorporated into the code. The applicable energy of DARWIN was extended to 1 GeV using the response functions calculated by the modified SCINFUL-QMD code.

  2. An Introduction to the Extensible Markup Language (XML).

    ERIC Educational Resources Information Center

    Bryan, Martin

    1998-01-01

    Describes Extensible Markup Language (XML), a subset of the Standard Generalized Markup Language (SGML) that is designed to make it easy to interchange structured documents over the Internet. Topics include Document Type Definition (DTD), components of XML, the use of XML, text and non-text elements, and uses for XML-coded files. (LRW)

  3. 76 FR 9358 - Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-17

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [MTM 067221] Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; Montana AGENCY: Bureau of Land Management, Interior. ACTION.... Cynthia Staszak, Chief, Branch of Land Resources. [FR Doc. 2011-3617 Filed 2-16-11; 8:45 am] BILLING CODE...

  4. Workshop report - A validation study of Navier-Stokes codes for transverse injection into a Mach 2 flow

    NASA Technical Reports Server (NTRS)

    Eklund, Dean R.; Northam, G. B.; Mcdaniel, J. C.; Smith, Cliff

    1992-01-01

    A CFD (Computational Fluid Dynamics) competition was held at the Third Scramjet Combustor Modeling Workshop to assess the current state-of-the-art in CFD codes for the analysis of scramjet combustors. Solutions from six three-dimensional Navier-Stokes codes were compared for the case of staged injection of air behind a step into a Mach 2 flow. This case was investigated experimentally at the University of Virginia and extensive in-stream data was obtained. Code-to-code comparisons have been made with regard to both accuracy and efficiency. The turbulence models employed in the solutions are believed to be a major source of discrepancy between the six solutions.

  5. Interleaved concatenated codes: new perspectives on approaching the Shannon limit.

    PubMed

    Viterbi, A J; Viterbi, A M; Sindhushayana, N T

    1997-09-02

    The last few years have witnessed a significant decrease in the gap between the Shannon channel capacity limit and what is practically achievable. Progress has resulted from novel extensions of previously known coding techniques involving interleaved concatenated codes. A considerable body of simulation results is now available, supported by an important but limited theoretical basis. This paper presents a computational technique which further ties simulation results to the known theory and reveals a considerable reduction in the complexity required to approach the Shannon limit.

  6. Fully-Implicit Navier-Stokes (FIN-S)

    NASA Technical Reports Server (NTRS)

    Kirk, Benjamin S.

    2010-01-01

    FIN-S is a SUPG finite element code for flow problems under active development at NASA Lyndon B. Johnson Space Center and within PECOS: a) The code is built on top of the libMesh parallel, adaptive finite element library. b) The initial implementation of the code targeted supersonic/hypersonic laminar calorically perfect gas flows & conjugate heat transfer. c) Initial extension to thermochemical nonequilibrium about 9 months ago. d) The technologies in FIN-S have been enhanced through a strongly collaborative research effort with Sandia National Labs.

  7. A TDM link with channel coding and digital voice.

    NASA Technical Reports Server (NTRS)

    Jones, M. W.; Tu, K.; Harton, P. L.

    1972-01-01

    The features of a TDM (time-division multiplexed) link model are described. A PCM telemetry sequence was coded for error correction and multiplexed with a digitized voice channel. An all-digital implementation of a variable-slope delta modulation algorithm was used to digitize the voice channel. The results of extensive testing are reported. The measured coding gain and the system performance over a Gaussian channel are compared with theoretical predictions and computer simulations. Word intelligibility scores are reported as a measure of voice channel performance.

  8. TRASANA. Force Stratification System User Handbook.

    DTIC Science & Technology

    1977-09-01

    n - 4 u m W CL a 0-C C COCOc:11 7 k., 0 =. t.4 c-Ac( ~ lqa . U~ ~~~~~ p. c A? W 0=0 ’. 0 a - 0 - EO U=ON~.S4’ o S .0 p. . 0 0 0 ’ ft 0 LO Cl O.CCL. . k...ADGRU, USAF Institute of Technology I Chief, ADGRU, US Naval War College 1 Chief, US Elm, USAF Air-Ground Operations School 1 USA Rep, USMC Educ Cen...Marine Corps Dev and Educ Command I USA Rep, Comb Svc Spt Prog School, Atlantic I Commandant, USA Element, School of Music 1 Liaison Offices/Officers

  9. Blinatumomab and Pembrolizumab

    PubMed Central

    Tabor, Emily E.; Waddell, J. Aubrey; Solimando, Dominic A.

    2015-01-01

    The complexity of cancer chemotherapy requires pharmacists be familiar with the complicated regimens and highly toxic agents used. This column reviews various issues related to preparation, dispensing, and administration of antineoplastic therapy, and the agents, both commercially available and investigational, used to treat malignant diseases. Questions or suggestions for topics should be addressed to Dominic A. Solimando, Jr, President, Oncology Pharmacy Services, Inc., 4201 Wilson Blvd #110-545, Arlington, VA 22203, e-mail: OncRxSvc@comcast.net; or J. Aubrey Waddell, Professor, University of Tennessee College of Pharmacy; Oncology Pharmacist, Pharmacy Department, Blount Memorial Hospital, 907 E. Lamar Alexander Parkway, Maryville, TN 37804, e-mail: waddfour@charter.net. PMID:26448656

  10. Drug Monographs: Avelumab and Ribociclib.

    PubMed

    Waddell, J Aubrey; Solimando, Dominic A

    2017-07-01

    The complexity of cancer chemotherapy requires pharmacists be familiar with the complicated regimens and highly toxic agents used. This column reviews various issues related to preparation, dispensing, and administration of antineoplastic therapy, and the agents, both commercially available and investigational, used to treat malignant diseases. Questions or suggestions for topics should be addressed to Dominic A. Solimando, Jr, President, Oncology Pharmacy Services, Inc, 4201 Wilson Blvd #110-545, Arlington, VA 22203, email: OncRxSvc@comcast.net; or J. Aubrey Waddell, Professor, University of Tennessee College of Pharmacy; Oncology Pharmacist, Pharmacy Department, Blount Memorial Hospital, 907 E. Lamar Alexander Parkway, Maryville, TN 37804, e-mail: waddfour@charter.net.

  11. Drug Monographs: Ixazomib and Necitumumab.

    PubMed

    Lawson, Fern E; Waddell, J Aubrey; Solimando, Dominic A

    2016-05-01

    The complexity of cancer chemotherapy requires pharmacists be familiar with the complicated regimens and highly toxic agents used. This column reviews various issues related to preparation, dispensing, and administration of antineoplastic therapy, and the agents, both commercially available and investigational, used to treat malignant diseases. Questions or suggestions for topics should be addressed to Dominic A. Solimando, Jr, President, Oncology Pharmacy Services, Inc., 4201 Wilson Blvd #110-545, Arlington, VA 22203, e-mail: OncRxSvc@comcast.net; or J. Aubrey Waddell, Professor, University of Tennessee College of Pharmacy; Oncology Pharmacist, Pharmacy Department, Blount Memorial Hospital, 907 E. Lamar Alexander Parkway, Maryville, TN 37804, e-mail: waddfour@charter.net.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xiaohu; Shi, Di; Wang, Zhiwei

    Shunt FACTS devices, such as, a Static Var Compensator (SVC), are capable of providing local reactive power compensation. They are widely used in the network to reduce the real power loss and improve the voltage profile. This paper proposes a planning model based on mixed integer conic programming (MICP) to optimally allocate SVCs in the transmission network considering load uncertainty. The load uncertainties are represented by a number of scenarios. Reformulation and linearization techniques are utilized to transform the original non-convex model into a convex second order cone programming (SOCP) model. Numerical case studies based on the IEEE 30-bus systemmore » demonstrate the effectiveness of the proposed planning model.« less

  13. Coding response to a case-mix measurement system based on multiple diagnoses.

    PubMed

    Preyra, Colin

    2004-08-01

    To examine the hospital coding response to a payment model using a case-mix measurement system based on multiple diagnoses and the resulting impact on a hospital cost model. Financial, clinical, and supplementary data for all Ontario short stay hospitals from years 1997 to 2002. Disaggregated trends in hospital case-mix growth are examined for five years following the adoption of an inpatient classification system making extensive use of combinations of secondary diagnoses. Hospital case mix is decomposed into base and complexity components. The longitudinal effects of coding variation on a standard hospital payment model are examined in terms of payment accuracy and impact on adjustment factors. Introduction of the refined case-mix system provided incentives for hospitals to increase reporting of secondary diagnoses and resulted in growth in highest complexity cases that were not matched by increased resource use over time. Despite a pronounced coding response on the part of hospitals, the increase in measured complexity and case mix did not reduce the unexplained variation in hospital unit cost nor did it reduce the reliance on the teaching adjustment factor, a potential proxy for case mix. The main implication was changes in the size and distribution of predicted hospital operating costs. Jurisdictions introducing extensive refinements to standard diagnostic related group (DRG)-type payment systems should consider the effects of induced changes to hospital coding practices. Assessing model performance should include analysis of the robustness of classification systems to hospital-level variation in coding practices. Unanticipated coding effects imply that case-mix models hypothesized to perform well ex ante may not meet expectations ex post.

  14. The Mitochondrial Cytochrome Oxidase Subunit I Gene Occurs on a Minichromosome with Extensive Heteroplasmy in Two Species of Chewing Lice, Geomydoecus aurei and Thomomydoecus minor

    PubMed Central

    Pietan, Lucas L.; Spradling, Theresa A.

    2016-01-01

    In animals, mitochondrial DNA (mtDNA) typically occurs as a single circular chromosome with 13 protein-coding genes and 22 tRNA genes. The various species of lice examined previously, however, have shown mitochondrial genome rearrangements with a range of chromosome sizes and numbers. Our research demonstrates that the mitochondrial genomes of two species of chewing lice found on pocket gophers, Geomydoecus aurei and Thomomydoecus minor, are fragmented with the 1,536 base-pair (bp) cytochrome-oxidase subunit I (cox1) gene occurring as the only protein-coding gene on a 1,916–1,964 bp minicircular chromosome in the two species, respectively. The cox1 gene of T. minor begins with an atypical start codon, while that of G. aurei does not. Components of the non-protein coding sequence of G. aurei and T. minor include a tRNA (isoleucine) gene, inverted repeat sequences consistent with origins of replication, and an additional non-coding region that is smaller than the non-coding sequence of other lice with such fragmented mitochondrial genomes. Sequences of cox1 minichromosome clones for each species reveal extensive length and sequence heteroplasmy in both coding and noncoding regions. The highly variable non-gene regions of G. aurei and T. minor have little sequence similarity with one another except for a 19-bp region of phylogenetically conserved sequence with unknown function. PMID:27589589

  15. 76 FR 13435 - Agency Information Collection Activities: Extension of a Previously Approved Collection; Comments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... DEPARTMENT OF JUSTICE [OMB Number 1103-0094] Agency Information Collection Activities: Extension... public comment until May 10, 2011. This process is conducted in accordance with 5 CFR 1320.10. If you.... Department of Justice. [FR Doc. 2011-5678 Filed 3-10-11; 8:45 am] BILLING CODE 4410-AT-P ...

  16. 75 FR 11079 - Extension of Public Comment Period for Water Quality Standards for the State of Florida's Lakes...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-10

    ... Extension of Public Comment Period for Water Quality Standards for the State of Florida's Lakes and Flowing... comment period. SUMMARY: On January 14, 2010, EPA signed a proposed rule entitled ``Water Quality.... Mail to: Water Docket, U.S. Environmental Protection Agency, Mail code: 2822T, 1200 Pennsylvania Avenue...

  17. XML Style Guide

    DTIC Science & Technology

    2015-07-01

    Acronyms ASCII American Standard Code for Information Interchange DAU data acquisition unit DDML data display markup language IHAL...Transfer Standard URI uniform resource identifier W3C World Wide Web Consortium XML extensible markup language XSD XML schema definition XML Style...Style Guide, RCC 125-15, July 2015 1 Introduction The next generation of telemetry systems will rely heavily on extensible markup language (XML

  18. 76 FR 31977 - Public Land Order No. 7768; Extension of Public Land Order No. 6861; Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMTB01000-L14300000.ET0000; MTM 79264] Public Land Order No. 7768; Extension of Public Land Order No. 6861; Montana AGENCY: Bureau of Land... and Minerals Management. [FR Doc. 2011-13720 Filed 6-1-11; 8:45 am] BILLING CODE P ...

  19. 76 FR 41516 - Notice of Proposed Withdrawal Extension and Notification of a Public Meeting; Montana; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-14

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [61510-8451-0000; MTM 80092] Notice of Proposed Withdrawal Extension and Notification of a Public Meeting; Montana; Correction AGENCY: Bureau of... Staszak, Chief, Branch of Land Resources. [FR Doc. 2011-17716 Filed 7-13-11; 8:45 am] BILLING CODE 4310-55...

  20. 75 FR 55604 - Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; Montana

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-13

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [LLMTM01000-L14300000.ET0000; MTM 79264] Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; Montana AGENCY: Bureau of... Miller, Acting Chief, Branch of Land Resources. [FR Doc. 2010-22740 Filed 9-10-10; 8:45 am] BILLING CODE...

  1. Progressive video coding for noisy channels

    NASA Astrophysics Data System (ADS)

    Kim, Beong-Jo; Xiong, Zixiang; Pearlman, William A.

    1998-10-01

    We extend the work of Sherwood and Zeger to progressive video coding for noisy channels. By utilizing a 3D extension of the set partitioning in hierarchical trees (SPIHT) algorithm, we cascade the resulting 3D SPIHT video coder with a rate-compatible punctured convolutional channel coder for transmission of video over a binary symmetric channel. Progressive coding is achieved by increasing the target rate of the 3D embedded SPIHT video coder as the channel condition improves. The performance of our proposed coding system is acceptable at low transmission rate and bad channel conditions. Its low complexity makes it suitable for emerging applications such as video over wireless channels.

  2. Finite difference time domain electromagnetic scattering from frequency-dependent lossy materials

    NASA Technical Reports Server (NTRS)

    Luebbers, Raymond J.; Beggs, John H.

    1991-01-01

    Four different FDTD computer codes and companion Radar Cross Section (RCS) conversion codes on magnetic media are submitted. A single three dimensional dispersive FDTD code for both dispersive dielectric and magnetic materials was developed, along with a user's manual. The extension of FDTD to more complicated materials was made. The code is efficient and is capable of modeling interesting radar targets using a modest computer workstation platform. RCS results for two different plate geometries are reported. The FDTD method was also extended to computing far zone time domain results in two dimensions. Also the capability to model nonlinear materials was incorporated into FDTD and validated.

  3. AN EXTENSION OF THE ATHENA++ CODE FRAMEWORK FOR GRMHD BASED ON ADVANCED RIEMANN SOLVERS AND STAGGERED-MESH CONSTRAINED TRANSPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Christopher J.; Stone, James M.; Gammie, Charles F.

    2016-08-01

    We present a new general relativistic magnetohydrodynamics (GRMHD) code integrated into the Athena++ framework. Improving upon the techniques used in most GRMHD codes, ours allows the use of advanced, less diffusive Riemann solvers, in particular HLLC and HLLD. We also employ a staggered-mesh constrained transport algorithm suited for curvilinear coordinate systems in order to maintain the divergence-free constraint of the magnetic field. Our code is designed to work with arbitrary stationary spacetimes in one, two, or three dimensions, and we demonstrate its reliability through a number of tests. We also report on its promising performance and scalability.

  4. Definite Integrals, Some Involving Residue Theory Evaluated by Maple Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, Kimiko o

    2010-01-01

    The calculus of residue is applied to evaluate certain integrals in the range (-{infinity} to {infinity}) using the Maple symbolic code. These integrals are of the form {integral}{sub -{infinity}}{sup {infinity}} cos(x)/[(x{sup 2} + a{sup 2})(x{sup 2} + b{sup 2}) (x{sup 2} + c{sup 2})]dx and similar extensions. The Maple code is also applied to expressions in maximum likelihood estimator moments when sampling from the negative binomial distribution. In general the Maple code approach to the integrals gives correct answers to specified decimal places, but the symbolic result may be extremely long and complex.

  5. Not All Order Memory Is Equal: Test Demands Reveal Dissociations in Memory for Sequence Information

    ERIC Educational Resources Information Center

    Jonker, Tanya R.; MacLeod, Colin M.

    2017-01-01

    Remembering the order of a sequence of events is a fundamental feature of episodic memory. Indeed, a number of formal models represent temporal context as part of the memory system, and memory for order has been researched extensively. Yet, the nature of the code(s) underlying sequence memory is still relatively unknown. Across 4 experiments that…

  6. 77 FR 69897 - Comment Request for Information Collection for Occupational Code Assignment, Extension Without...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    ....onetcenter.org/ombclearance.html . DATES: Written comments must be submitted to the office listed in the... information in the O*NET Web sites including O*NET OnLine ( http://online.onetcenter.org ), My Next Move ( www.MyNextMove.gov ) and My Next Move for Veterans ( www.MyNextMove.org/vets ) O*NET Code Connector ( www...

  7. Picture data compression coder using subband/transform coding with a Lempel-Ziv-based coder

    NASA Technical Reports Server (NTRS)

    Glover, Daniel R. (Inventor)

    1995-01-01

    Digital data coders/decoders are used extensively in video transmission. A digitally encoded video signal is separated into subbands. Separating the video into subbands allows transmission at low data rates. Once the data is separated into these subbands it can be coded and then decoded by statistical coders such as the Lempel-Ziv based coder.

  8. A three-dimensional code for muon propagation through the rock: MUSIC

    NASA Astrophysics Data System (ADS)

    Antonioli, P.; Ghetti, C.; Korolkova, E. V.; Kudryavtsev, V. A.; Sartorelli, G.

    1997-10-01

    We present a new three-dimensional Monte-Carlo code MUSIC (MUon SImulation Code) for muon propagation through the rock. All processes of muon interaction with matter with high energy loss (including the knock-on electron production) are treated as stochastic processes. The angular deviation and lateral displacement of muons due to multiple scattering, as well as bremsstrahlung, pair production and inelastic scattering are taken into account. The code has been applied to obtain the energy distribution and angular and lateral deviations of single muons at different depths underground. The muon multiplicity distributions obtained with MUSIC and CORSIKA (Extensive Air Shower simulation code) are also presented. We discuss the systematic uncertainties of the results due to different muon bremsstrahlung cross-sections.

  9. The Julia programming language: the future of scientific computing

    NASA Astrophysics Data System (ADS)

    Gibson, John

    2017-11-01

    Julia is an innovative new open-source programming language for high-level, high-performance numerical computing. Julia combines the general-purpose breadth and extensibility of Python, the ease-of-use and numeric focus of Matlab, the speed of C and Fortran, and the metaprogramming power of Lisp. Julia uses type inference and just-in-time compilation to compile high-level user code to machine code on the fly. A rich set of numeric types and extensive numerical libraries are built-in. As a result, Julia is competitive with Matlab for interactive graphical exploration and with C and Fortran for high-performance computing. This talk interactively demonstrates Julia's numerical features and benchmarks Julia against C, C++, Fortran, Matlab, and Python on a spectral time-stepping algorithm for a 1d nonlinear partial differential equation. The Julia code is nearly as compact as Matlab and nearly as fast as Fortran. This material is based upon work supported by the National Science Foundation under Grant No. 1554149.

  10. Improvement of Mishchenko's T-matrix code for absorbing particles.

    PubMed

    Moroz, Alexander

    2005-06-10

    The use of Gaussian elimination with backsubstitution for matrix inversion in scattering theories is discussed. Within the framework of the T-matrix method (the state-of-the-art code by Mishchenko is freely available at http://www.giss.nasa.gov/-crmim), it is shown that the domain of applicability of Mishchenko's FORTRAN 77 (F77) code can be substantially expanded in the direction of strongly absorbing particles where the current code fails to converge. Such an extension is especially important if the code is to be used in nanoplasmonic or nanophotonic applications involving metallic particles. At the same time, convergence can also be achieved for large nonabsorbing particles, in which case the non-Numerical Algorithms Group option of Mishchenko's code diverges. Computer F77 implementation of Mishchenko's code supplemented with Gaussian elimination with backsubstitution is freely available at http://www.wave-scattering.com.

  11. Genetic Code Analysis Toolkit: A novel tool to explore the coding properties of the genetic code and DNA sequences

    NASA Astrophysics Data System (ADS)

    Kraljić, K.; Strüngmann, L.; Fimmel, E.; Gumbel, M.

    2018-01-01

    The genetic code is degenerated and it is assumed that redundancy provides error detection and correction mechanisms in the translation process. However, the biological meaning of the code's structure is still under current research. This paper presents a Genetic Code Analysis Toolkit (GCAT) which provides workflows and algorithms for the analysis of the structure of nucleotide sequences. In particular, sets or sequences of codons can be transformed and tested for circularity, comma-freeness, dichotomic partitions and others. GCAT comes with a fertile editor custom-built to work with the genetic code and a batch mode for multi-sequence processing. With the ability to read FASTA files or load sequences from GenBank, the tool can be used for the mathematical and statistical analysis of existing sequence data. GCAT is Java-based and provides a plug-in concept for extensibility. Availability: Open source Homepage:http://www.gcat.bio/

  12. The maximum vector-angular margin classifier and its fast training on large datasets using a core vector machine.

    PubMed

    Hu, Wenjun; Chung, Fu-Lai; Wang, Shitong

    2012-03-01

    Although pattern classification has been extensively studied in the past decades, how to effectively solve the corresponding training on large datasets is a problem that still requires particular attention. Many kernelized classification methods, such as SVM and SVDD, can be formulated as the corresponding quadratic programming (QP) problems, but computing the associated kernel matrices requires O(n2)(or even up to O(n3)) computational complexity, where n is the size of the training patterns, which heavily limits the applicability of these methods for large datasets. In this paper, a new classification method called the maximum vector-angular margin classifier (MAMC) is first proposed based on the vector-angular margin to find an optimal vector c in the pattern feature space, and all the testing patterns can be classified in terms of the maximum vector-angular margin ρ, between the vector c and all the training data points. Accordingly, it is proved that the kernelized MAMC can be equivalently formulated as the kernelized Minimum Enclosing Ball (MEB), which leads to a distinctive merit of MAMC, i.e., it has the flexibility of controlling the sum of support vectors like v-SVC and may be extended to a maximum vector-angular margin core vector machine (MAMCVM) by connecting the core vector machine (CVM) method with MAMC such that the corresponding fast training on large datasets can be effectively achieved. Experimental results on artificial and real datasets are provided to validate the power of the proposed methods. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Extending R packages to support 64-bit compiled code: An illustration with spam64 and GIMMS NDVI3g data

    NASA Astrophysics Data System (ADS)

    Gerber, Florian; Mösinger, Kaspar; Furrer, Reinhard

    2017-07-01

    Software packages for spatial data often implement a hybrid approach of interpreted and compiled programming languages. The compiled parts are usually written in C, C++, or Fortran, and are efficient in terms of computational speed and memory usage. Conversely, the interpreted part serves as a convenient user-interface and calls the compiled code for computationally demanding operations. The price paid for the user friendliness of the interpreted component is-besides performance-the limited access to low level and optimized code. An example of such a restriction is the 64-bit vector support of the widely used statistical language R. On the R side, users do not need to change existing code and may not even notice the extension. On the other hand, interfacing 64-bit compiled code efficiently is challenging. Since many R packages for spatial data could benefit from 64-bit vectors, we investigate strategies to efficiently pass 64-bit vectors to compiled languages. More precisely, we show how to simply extend existing R packages using the foreign function interface to seamlessly support 64-bit vectors. This extension is shown with the sparse matrix algebra R package spam. The new capabilities are illustrated with an example of GIMMS NDVI3g data featuring a parametric modeling approach for a non-stationary covariance matrix.

  14. Interleaved concatenated codes: New perspectives on approaching the Shannon limit

    PubMed Central

    Viterbi, A. J.; Viterbi, A. M.; Sindhushayana, N. T.

    1997-01-01

    The last few years have witnessed a significant decrease in the gap between the Shannon channel capacity limit and what is practically achievable. Progress has resulted from novel extensions of previously known coding techniques involving interleaved concatenated codes. A considerable body of simulation results is now available, supported by an important but limited theoretical basis. This paper presents a computational technique which further ties simulation results to the known theory and reveals a considerable reduction in the complexity required to approach the Shannon limit. PMID:11038568

  15. Towards a Framework for Generating Tests to Satisfy Complex Code Coverage in Java Pathfinder

    NASA Technical Reports Server (NTRS)

    Staats, Matt

    2009-01-01

    We present work on a prototype tool based on the JavaPathfinder (JPF) model checker for automatically generating tests satisfying the MC/DC code coverage criterion. Using the Eclipse IDE, developers and testers can quickly instrument Java source code with JPF annotations covering all MC/DC coverage obligations, and JPF can then be used to automatically generate tests that satisfy these obligations. The prototype extension to JPF enables various tasks useful in automatic test generation to be performed, such as test suite reduction and execution of generated tests.

  16. Improvements and applications of COBRA-TF for stand-alone and coupled LWR safety analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avramova, M.; Cuervo, D.; Ivanov, K.

    2006-07-01

    The advanced thermal-hydraulic subchannel code COBRA-TF has been recently improved and applied for stand-alone and coupled LWR core calculations at the Pennsylvania State Univ. in cooperation with AREVA NP GmbH (Germany)) and the Technical Univ. of Madrid. To enable COBRA-TF for academic and industrial applications including safety margins evaluations and LWR core design analyses, the code programming, numerics, and basic models were revised and substantially improved. The code has undergone through an extensive validation, verification, and qualification program. (authors)

  17. An extensible circuit QED architecture for quantum computation

    NASA Astrophysics Data System (ADS)

    Dicarlo, Leo

    Realizing a logical qubit robust to single errors in its constituent physical elements is an immediate challenge for quantum information processing platforms. A longer-term challenge will be achieving quantum fault tolerance, i.e., improving logical qubit resilience by increasing redundancy in the underlying quantum error correction code (QEC). In QuTech, we target these challenges in collaboration with industrial and academic partners. I will present the circuit QED quantum hardware, room-temperature control electronics, and software components of the complete architecture. I will show the extensibility of each component to the Surface-17 and -49 circuits needed to reach the objectives with surface-code QEC, and provide an overview of latest developments. Research funded by IARPA and Intel Corporation.

  18. Aeroacoustic Codes for Rotor Harmonic and BVI Noise. CAMRAD.Mod1/HIRES: Methodology and Users' Manual

    NASA Technical Reports Server (NTRS)

    Boyd, D. Douglas, Jr.; Brooks, Thomas F.; Burley, Casey L.; Jolly, J. Ralph, Jr.

    1998-01-01

    This document details the methodology and use of the CAMRAD.Mod1/HIRES codes, which were developed at NASA Langley Research Center for the prediction of helicopter harmonic and Blade-Vortex Interaction (BVI) noise. CANMAD.Mod1 is a substantially modified version of the performance/trim/wake code CANMAD. High resolution blade loading is determined in post-processing by HIRES and an associated indicial aerodynamics code. Extensive capabilities of importance to noise prediction accuracy are documented, including a new multi-core tip vortex roll-up wake model, higher harmonic and individual blade control, tunnel and fuselage correction input, diagnostic blade motion input, and interfaces for acoustic and CFD aerodynamics codes. Modifications and new code capabilities are documented with examples. A users' job preparation guide and listings of variables and namelists are given.

  19. Combustion chamber analysis code

    NASA Technical Reports Server (NTRS)

    Przekwas, A. J.; Lai, Y. G.; Krishnan, A.; Avva, R. K.; Giridharan, M. G.

    1993-01-01

    A three-dimensional, time dependent, Favre averaged, finite volume Navier-Stokes code has been developed to model compressible and incompressible flows (with and without chemical reactions) in liquid rocket engines. The code has a non-staggered formulation with generalized body-fitted-coordinates (BFC) capability. Higher order differencing methodologies such as MUSCL and Osher-Chakravarthy schemes are available. Turbulent flows can be modeled using any of the five turbulent models present in the code. A two-phase, two-liquid, Lagrangian spray model has been incorporated into the code. Chemical equilibrium and finite rate reaction models are available to model chemically reacting flows. The discrete ordinate method is used to model effects of thermal radiation. The code has been validated extensively against benchmark experimental data and has been applied to model flows in several propulsion system components of the SSME and the STME.

  20. Integrated Composite Analyzer (ICAN): Users and programmers manual

    NASA Technical Reports Server (NTRS)

    Murthy, P. L. N.; Chamis, C. C.

    1986-01-01

    The use of and relevant equations programmed in a computer code designed to carry out a comprehensive linear analysis of multilayered fiber composites is described. The analysis contains the essential features required to effectively design structural components made from fiber composites. The inputs to the code are constituent material properties, factors reflecting the fabrication process, and composite geometry. The code performs micromechanics, macromechanics, and laminate analysis, including the hygrothermal response of fiber composites. The code outputs are the various ply and composite properties, composite structural response, and composite stress analysis results with details on failure. The code is in Fortran IV and can be used efficiently as a package in complex structural analysis programs. The input-output format is described extensively through the use of a sample problem. The program listing is also included. The code manual consists of two parts.

  1. Thermodynamic Analysis of the Combustion of Metallic Materials

    NASA Technical Reports Server (NTRS)

    Wilson, D. Bruce; Stoltzfus, Joel M.

    2000-01-01

    Two types of computer codes are available to assist in the thermodynamic analysis of metallic materials combustion. One type of code calculates phase equilibrium data and is represented by CALPHAD. The other type of code calculates chemical reaction by the Gordon-McBride code. The first has seen significant application for alloy-phase diagrams, but only recently has it been considered for oxidation systems. The Gordon-McBride code has been applied to the combustion of metallic materials. Both codes are limited by their treatment of non-ideal solutions and the fact they are limited to treating volatile and gaseous species as ideal. This paper examines the significance of these limitations for combustion of metallic materials. In addition, the applicability of linear-free energy relationships for solid-phase oxidation and their possible extension to liquid-phase systems is examined.

  2. Automatic Multilevel Parallelization Using OpenMP

    NASA Technical Reports Server (NTRS)

    Jin, Hao-Qiang; Jost, Gabriele; Yan, Jerry; Ayguade, Eduard; Gonzalez, Marc; Martorell, Xavier; Biegel, Bryan (Technical Monitor)

    2002-01-01

    In this paper we describe the extension of the CAPO parallelization support tool to support multilevel parallelism based on OpenMP directives. CAPO generates OpenMP directives with extensions supported by the NanosCompiler to allow for directive nesting and definition of thread groups. We report first results for several benchmark codes and one full application that have been parallelized using our system.

  3. 76 FR 5564 - Grant of Interim Extension of the Term of U.S. Patent No. 4,971,802; MIFAMURTIDE

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-01

    ... DEPARTMENT OF COMMERCE Patent and Trademark Office [Docket No. PTO-P-2011-0001] Grant of Interim... Office, Commerce. ACTION: Notice of interim patent term extension. SUMMARY: The United States Patent and... States Patent and Trademark Office. [FR Doc. 2011-2088 Filed 1-31-11; 8:45 am] BILLING CODE 3510-16-P ...

  4. Coding Response to a Case-Mix Measurement System Based on Multiple Diagnoses

    PubMed Central

    Preyra, Colin

    2004-01-01

    Objective To examine the hospital coding response to a payment model using a case-mix measurement system based on multiple diagnoses and the resulting impact on a hospital cost model. Data Sources Financial, clinical, and supplementary data for all Ontario short stay hospitals from years 1997 to 2002. Study Design Disaggregated trends in hospital case-mix growth are examined for five years following the adoption of an inpatient classification system making extensive use of combinations of secondary diagnoses. Hospital case mix is decomposed into base and complexity components. The longitudinal effects of coding variation on a standard hospital payment model are examined in terms of payment accuracy and impact on adjustment factors. Principal Findings Introduction of the refined case-mix system provided incentives for hospitals to increase reporting of secondary diagnoses and resulted in growth in highest complexity cases that were not matched by increased resource use over time. Despite a pronounced coding response on the part of hospitals, the increase in measured complexity and case mix did not reduce the unexplained variation in hospital unit cost nor did it reduce the reliance on the teaching adjustment factor, a potential proxy for case mix. The main implication was changes in the size and distribution of predicted hospital operating costs. Conclusions Jurisdictions introducing extensive refinements to standard diagnostic related group (DRG)-type payment systems should consider the effects of induced changes to hospital coding practices. Assessing model performance should include analysis of the robustness of classification systems to hospital-level variation in coding practices. Unanticipated coding effects imply that case-mix models hypothesized to perform well ex ante may not meet expectations ex post. PMID:15230940

  5. MIADS2 ... an alphanumeric map information assembly and display system for a large computer

    Treesearch

    Elliot L. Amidon

    1966-01-01

    A major improvement and extension of the Map Information Assembly and Display System (MIADS) developed in 1964 is described. Basic principles remain unchanged, but the computer programs have been expanded and rewritten for a large computer, in Fortran IV and MAP languages. The code system is extended from 99 integers to about 2,200 alphanumeric 2-character codes. Hand-...

  6. Tectonic control and mass-wasting processes along S. Vicente Canyon (SW Iberia): evidences from multibeam bathymetry and seismic reflection data

    NASA Astrophysics Data System (ADS)

    Valadares, V.; Roque, C.; Terrinha, P.

    2009-04-01

    The S. Vicente Canyon is located in the Gulf of Cadiz (GoC), in the Northwest Atlantic Ocean, offshore SW Iberia. The GoC is located between the Straits of Gibraltar (5°W) and the Gorringe Bank (12°W) and 34°N and 38°N. It is situated in a complex geodynamic setting at the Eastern tip of the Azores-Gibraltar fracture zone, part of the convergent plate boundary between Northwest Africa and Southwest Eurasia. There are several evidences for active tectonics, moderate seismic activity and some events of high magnitude for earthquakes and tsunamis (like the 1755 and 1969 events). The canyon lies between two of the most prominent faults in the GoC: the Marquês de Pombal and the Horseshoe thrust faults. Since the 1990's nineteen multibeam swath bathymetry surveys were carried out in the Gulf of Cadiz and a compilation of the data was produced adding up to more than 180.000km2. This 100m cellsize compilation allowed a detailed analysis of the seafloor of the GoC including the South and Western Portuguese margins and is in the junction point between these two margins that the S. Vicente Canyon (SVC) is located. The bathymetry data here presented is derived from the MATESPRO survey from 2004, the first large multibeam swath bathymetry survey in the area. The canyon has a general staircase-like shape with the upper and lower parts trending NE-SW and the middle sector with an NNE-SSW direction. The SVC head lies very close to the shore, at depths shallower than 70m and runs towards the Horseshoe Abyssal Plain (HAP) at around 4900m depth. It extends for more than 120km (larger than any other submarine canyon on the GoC) and can reach up to 20 km in width. The walls are steep and frequently affected by mass wasting scars and also strongly incised by minor contributories valleys. A major kink is present where the canyon diverts about 60° from its upper course, as well as several minor ones and some knickpoints are also identifiable across its entire track. Across its length the morphology changes: the SE side is the steepest for the upper and deepest parts, whilst for the intermediate sector the NW wall is steeper. Its head has an amphitheater shape due to the pattern defined by its minor contributories as a result of slumps and slides and therefore appears to be retreating upslope in the direction of the shore. Reflectivity imagery derived from the multibeam probe shows high reflectance throughout the whole of the S. Vicente Canyon thalweg indicating that the canyon and its sedimentary transport are active in present times. The HAP also shows a relatively high backscatter response, probably related to the abundant turbidite deposits whose coarse sedimentary load was partially carried by the SVC. Inspection of several multichannel seismic profiles revealed that the two major structures that are more closely located to the canyon present a polyphase and complex history. The Marquês de Pombal Thrust (MPT), located to the NW of the SVC, reveals an extensional activity during continental break-up in the Mesozoic. The compressive episodes started in the Eocene/Oligocene (and extended until present times) and were followed by other compressive events, the more relevant ones in the Late Miocene. The Horseshoe Thrust Fault, located SE of the deepest section of the canyon, revealed no major extensional events and shows a compressional history somewhat similar to the previously described MPT. These events and the compressive history is related with the relative movement between Africa and Iberia and the tectonic plate boundary convergence. The compressive episodes and fault activity during the Miocene have led to the uplift of this sector of the margin, causing major erosion onshore, redistributing sediments and leading to the submarine incision and canyon formation after the Miocene, more precisely in Lower Pliocene times.

  7. A comparison between implicit and hybrid methods for the calculation of steady and unsteady inlet flows

    NASA Technical Reports Server (NTRS)

    Coakley, T. J.; Hsieh, T.

    1985-01-01

    Numerical simulation of steady and unsteady transonic diffuser flows using two different computer codes are discussed and compared with experimental data. The codes solve the Reynolds-averaged, compressible, Navier-Stokes equations using various turbulence models. One of the codes has been applied extensively to diffuser flows and uses the hybrid method of MacCormack. This code is relatively inefficient numerically. The second code, which was developed more recently, is fully implicit and is relatively efficient numerically. Simulations of steady flows using the implicit code are shown to be in good agreement with simulations using the hybrid code. Both simulations are in good agreement with experimental results. Simulations of unsteady flows using the two codes are in good qualitative agreement with each other, although the quantitative agreement is not as good as in the steady flow cases. The implicit code is shown to be eight times faster than the hybrid code for unsteady flow calculations and up to 32 times faster for steady flow calculations. Results of calculations using alternative turbulence models are also discussed.

  8. The Development of the World Anti-Doping Code.

    PubMed

    Young, Richard

    2017-01-01

    This chapter addresses both the development and substance of the World Anti-Doping Code, which came into effect in 2003, as well as the subsequent Code amendments, which came into effect in 2009 and 2015. Through an extensive process of stakeholder input and collaboration, the World Anti-Doping Code has transformed the hodgepodge of inconsistent and competing pre-2003 anti-doping rules into a harmonized and effective approach to anti-doping. The Code, as amended, is now widely recognized worldwide as the gold standard in anti-doping. The World Anti-Doping Code originally went into effect on January 1, 2004. The first amendments to the Code went into effect on January 1, 2009, and the second amendments on January 1, 2015. The Code and the related international standards are the product of a long and collaborative process designed to make the fight against doping more effective through the adoption and implementation of worldwide harmonized rules and best practices. © 2017 S. Karger AG, Basel.

  9. MKHITAR GOSH'S MEDIEVAL LAW CODE AND ITS IMPLICATIONS FOR ARMENIAN COMMUNITIES ABROAD.

    PubMed

    Davtyan, Susanna; Khachatryan, Mikayel; Johrian, Ara; Ghazaryan, Karen

    2014-07-01

    The Law Book of the medieval Armenian legal and economic thought is an exceptional work that encompasses valuable information of the Armenian nation's domestic life. Mkhitar Gosh was considered to be one of the most outstanding figures and lawyers (lawmakers) of all times. Armenian Law Code after Mkhitar Gosh is writhed at 12 century. One of the primary sources for the law code was Armenian customary law. This Code became moral code for guiding for hall Armenians over the world because of high moral spirit reflecting Armenian mentality. This article presents the brief history of extension of legal rules setting out in the Law Code. The Law Code was established and widely used not only in Armenia but also in a number of Armenian communities abroad (Russian, Poland, Georgia, Latvia, India etc.). Law Code was accepted by all Armenians. Moreover, it served for the development of legislation for a number of civilized European and Asian countries.

  10. Development of V/STOL methodology based on a higher order panel method

    NASA Technical Reports Server (NTRS)

    Bhateley, I. C.; Howell, G. A.; Mann, H. W.

    1983-01-01

    The development of a computational technique to predict the complex flowfields of V/STOL aircraft was initiated in which a number of modules and a potential flow aerodynamic code were combined in a comprehensive computer program. The modules were developed in a building-block approach to assist the user in preparing the geometric input and to compute parameters needed to simulate certain flow phenomena that cannot be handled directly within a potential flow code. The PAN AIR aerodynamic code, which is higher order panel method, forms the nucleus of this program. PAN AIR's extensive capability for allowing generalized boundary conditions allows the modules to interact with the aerodynamic code through the input and output files, thereby requiring no changes to the basic code and easy replacement of updated modules.

  11. Digital barcodes of suspension array using laser induced breakdown spectroscopy

    PubMed Central

    He, Qinghua; Liu, Yixi; He, Yonghong; Zhu, Liang; Zhang, Yilong; Shen, Zhiyuan

    2016-01-01

    We show a coding method of suspension array based on the laser induced breakdown spectroscopy (LIBS), which promotes the barcodes from analog to digital. As the foundation of digital optical barcodes, nanocrystals encoded microspheres are prepared with self-assembly encapsulation method. We confirm that digital multiplexing of LIBS-based coding method becomes feasible since the microsphere can be coded with direct read-out data of wavelengths, and the method can avoid fluorescence signal crosstalk between barcodes and analyte tags, which lead to overall advantages in accuracy and stability to current fluorescent multicolor coding method. This demonstration increases the capability of multiplexed detection and accurate filtrating, expanding more extensive applications of suspension array in life science. PMID:27808270

  12. Layered Wyner-Ziv video coding.

    PubMed

    Xu, Qian; Xiong, Zixiang

    2006-12-01

    Following recent theoretical works on successive Wyner-Ziv coding (WZC), we propose a practical layered Wyner-Ziv video coder using the DCT, nested scalar quantization, and irregular LDPC code based Slepian-Wolf coding (or lossless source coding with side information at the decoder). Our main novelty is to use the base layer of a standard scalable video coder (e.g., MPEG-4/H.26L FGS or H.263+) as the decoder side information and perform layered WZC for quality enhancement. Similar to FGS coding, there is no performance difference between layered and monolithic WZC when the enhancement bitstream is generated in our proposed coder. Using an H.26L coded version as the base layer, experiments indicate that WZC gives slightly worse performance than FGS coding when the channel (for both the base and enhancement layers) is noiseless. However, when the channel is noisy, extensive simulations of video transmission over wireless networks conforming to the CDMA2000 1X standard show that H.26L base layer coding plus Wyner-Ziv enhancement layer coding are more robust against channel errors than H.26L FGS coding. These results demonstrate that layered Wyner-Ziv video coding is a promising new technique for video streaming over wireless networks.

  13. A new code for Galileo

    NASA Technical Reports Server (NTRS)

    Dolinar, S.

    1988-01-01

    Over the past six to eight years, an extensive research effort was conducted to investigate advanced coding techniques which promised to yield more coding gain than is available with current NASA standard codes. The delay in Galileo's launch due to the temporary suspension of the shuttle program provided the Galileo project with an opportunity to evaluate the possibility of including some version of the advanced codes as a mission enhancement option. A study was initiated last summer to determine if substantial coding gain was feasible for Galileo and, is so, to recommend a suitable experimental code for use as a switchable alternative to the current NASA-standard code. The Galileo experimental code study resulted in the selection of a code with constant length 15 and rate 1/4. The code parameters were chosen to optimize performance within cost and risk constraints consistent with retrofitting the new code into the existing Galileo system design and launch schedule. The particular code was recommended after a very limited search among good codes with the chosen parameters. It will theoretically yield about 1.5 dB enhancement under idealizing assumptions relative to the current NASA-standard code at Galileo's desired bit error rates. This ideal predicted gain includes enough cushion to meet the project's target of at least 1 dB enhancement under real, non-ideal conditions.

  14. Fluid-solid interaction: benchmarking of an external coupling of ANSYS with CFX for cardiovascular applications.

    PubMed

    Hose, D R; Lawford, P V; Narracott, A J; Penrose, J M T; Jones, I P

    2003-01-01

    Fluid-solid interaction is a primary feature of cardiovascular flows. There is increasing interest in the numerical solution of these systems as the extensive computational resource required for such studies becomes available. One form of coupling is an external weak coupling of separate solid and fluid mechanics codes. Information about the stress tensor and displacement vector at the wetted boundary is passed between the codes, and an iterative scheme is employed to move towards convergence of these parameters at each time step. This approach has the attraction that separate codes with the most extensive functionality for each of the separate phases can be selected, which might be important in the context of the complex rheology and contact mechanics that often feature in cardiovascular systems. Penrose and Staples describe a weak coupling of CFX for computational fluid mechanics to ANSYS for solid mechanics, based on a simple Jacobi iteration scheme. It is important to validate the coupled numerical solutions. An extensive analytical study of flow in elastic-walled tubes was carried out by Womersley in the late 1950s. This paper describes the performance of the coupling software for the straight elastic-walled tube, and compares the results with Womersley's analytical solutions. It also presents preliminary results demonstrating the application of the coupled software in the context of a stented vessel.

  15. The Clawpack Community of Codes

    NASA Astrophysics Data System (ADS)

    Mandli, K. T.; LeVeque, R. J.; Ketcheson, D.; Ahmadia, A. J.

    2014-12-01

    Clawpack, the Conservation Laws Package, has long been one of the standards for solving hyperbolic conservation laws but over the years has extended well beyond this role. Today a community of open-source codes have been developed that address a multitude of different needs including non-conservative balance laws, high-order accurate methods, and parallelism while remaining extensible and easy to use, largely by the judicious use of Python and the original Fortran codes that it wraps. This talk will present some of the recent developments in projects under the Clawpack umbrella, notably the GeoClaw and PyClaw projects. GeoClaw was originally developed as a tool for simulating tsunamis using adaptive mesh refinement but has since encompassed a large number of other geophysically relevant flows including storm surge and debris-flows. PyClaw originated as a Python version of the original Clawpack algorithms but has since been both a testing ground for new algorithmic advances in the Clawpack framework but also an easily extensible framework for solving hyperbolic balance laws. Some of these extensions include the addition of WENO high-order methods, massively parallel capabilities, and adaptive mesh refinement technologies, made possible largely by the flexibility of the Python language and community libraries such as NumPy and PETSc. Because of the tight integration with Python tecnologies, both packages have benefited also from the focus on reproducibility in the Python community, notably IPython notebooks.

  16. The InSAR Scientific Computing Environment

    NASA Technical Reports Server (NTRS)

    Rosen, Paul A.; Gurrola, Eric; Sacco, Gian Franco; Zebker, Howard

    2012-01-01

    We have developed a flexible and extensible Interferometric SAR (InSAR) Scientific Computing Environment (ISCE) for geodetic image processing. ISCE was designed from the ground up as a geophysics community tool for generating stacks of interferograms that lend themselves to various forms of time-series analysis, with attention paid to accuracy, extensibility, and modularity. The framework is python-based, with code elements rigorously componentized by separating input/output operations from the processing engines. This allows greater flexibility and extensibility in the data models, and creates algorithmic code that is less susceptible to unnecessary modification when new data types and sensors are available. In addition, the components support provenance and checkpointing to facilitate reprocessing and algorithm exploration. The algorithms, based on legacy processing codes, have been adapted to assume a common reference track approach for all images acquired from nearby orbits, simplifying and systematizing the geometry for time-series analysis. The framework is designed to easily allow user contributions, and is distributed for free use by researchers. ISCE can process data from the ALOS, ERS, EnviSAT, Cosmo-SkyMed, RadarSAT-1, RadarSAT-2, and TerraSAR-X platforms, starting from Level-0 or Level 1 as provided from the data source, and going as far as Level 3 geocoded deformation products. With its flexible design, it can be extended with raw/meta data parsers to enable it to work with radar data from other platforms

  17. Final Environmental Assessment: Renovation of Child Development Centers Buildings 3904 and 5510 at Tinker Air Force Base, Oklahoma

    DTIC Science & Technology

    2009-08-28

    tmpatn lo tl•• 110 vcor • oodplatn n f uld 0 ol r-.a~ 1�~1 co.bl• Altem.nr v • ONPA) INO pul• ·( Is i•l¥’·1~ 1 1•1 ’""’th’ 1110 dt&U CJ\\ po.d...34Fire~" three or more times. The l!earest fire al11rm pull stat{()n will be acuvated by the nearest employee wh.ile OtheJ$ in the room begin Lo ...assemble children for evacuztion (Yeung Infant. Infant. and Pretoodler rooms will use wireeled evacuation devices). Supersedes SV~C Ols 215-5,9, and lO

  18. Aerothermodynamic Analysis of a Coanda/Refraction Jet Engine Test Facility

    DTIC Science & Technology

    1988-12-01

    characterS pet Iret. Temmeature frge Opealional 50 to t04V (t0 to 40*C) Storage - 20 to 140*P -30 to SVC). Power source The Mirrcintrr trenes In ewer from...approximately 322 K (I 18 F) [Ref. 8]. The analytical temperature of 325 K (122 F) compared quite favorably with the 322 K approximation. An exit...8.4735-32 6.1675-32 4.075S-02 2.5050-02, 1.0385-02 8.2675-03 0.731E-04 6.3130E-34 Iv- 10 1.729 E0C 1.0CCS- Si 6.6200-02 1.8590-02- 2.327E-02 1.1245-02

  19. SVC obstruction and stridor relieved by nasogastric tube insertion.

    PubMed

    Molena, Emma J; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-03-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2016.

  20. Practical moral codes in the transgenic organism debate.

    PubMed

    Cooley, D R; Goreham, Gary; Youngs, George A

    2004-01-01

    In one study funded by the United States Department of Agriculture, people from North Dakota were interviewed to discover which moral principles they use in evaluating the morality of transgenic organisms and their introduction into markets. It was found that although the moral codes the human subjects employed were very similar, their views on transgenics were vastly different. In this paper, the codes that were used by the respondents are developed, compared to that of the academically composed Belmont Report, and then modified to create the more practical Common Moral Code. At the end, it is shown that the Common Moral Code has inherent inconsistency flaws that might be resolvable, but would require extensive work on the definition of terms and principles. However, the effort is worthwhile, especially if it results in a common moral code that all those involved in the debate are willing to use in negotiating a resolution to their differences.

  1. Subjective evaluation of next-generation video compression algorithms: a case study

    NASA Astrophysics Data System (ADS)

    De Simone, Francesca; Goldmann, Lutz; Lee, Jong-Seok; Ebrahimi, Touradj; Baroncini, Vittorio

    2010-08-01

    This paper describes the details and the results of the subjective quality evaluation performed at EPFL, as a contribution to the effort of the Joint Collaborative Team on Video Coding (JCT-VC) for the definition of the next-generation video coding standard. The performance of 27 coding technologies have been evaluated with respect to two H.264/MPEG-4 AVC anchors, considering high definition (HD) test material. The test campaign involved a total of 494 naive observers and took place over a period of four weeks. While similar tests have been conducted as part of the standardization process of previous video coding technologies, the test campaign described in this paper is by far the most extensive in the history of video coding standardization. The obtained subjective quality scores show high consistency and support an accurate comparison of the performance of the different coding solutions.

  2. On the validation of a code and a turbulence model appropriate to circulation control airfoils

    NASA Technical Reports Server (NTRS)

    Viegas, J. R.; Rubesin, M. W.; Maccormack, R. W.

    1988-01-01

    A computer code for calculating flow about a circulation control airfoil within a wind tunnel test section has been developed. This code is being validated for eventual use as an aid to design such airfoils. The concept of code validation being used is explained. The initial stages of the process have been accomplished. The present code has been applied to a low-subsonic, 2-D flow about a circulation control airfoil for which extensive data exist. Two basic turbulence models and variants thereof have been successfully introduced into the algorithm, the Baldwin-Lomax algebraic and the Jones-Launder two-equation models of turbulence. The variants include adding a history of the jet development for the algebraic model and adding streamwise curvature effects for both models. Numerical difficulties and difficulties in the validation process are discussed. Turbulence model and code improvements to proceed with the validation process are also discussed.

  3. An object oriented extension to CLIPS

    NASA Technical Reports Server (NTRS)

    Sobkowicz, Clifford

    1990-01-01

    A presentation of software sub-system developed to augment C Language Production Systems (CLIPS) with facilities for object oriented Knowledge representation. Functions are provided to define classes, instantiate objects, access attributes, and assert object related facts. This extension is implemented via the CLIPS user function interface and does not require modification of any CLIPS code. It does rely on internal CLIPS functions for memory management and symbol representation.

  4. GDA (Geologic Data Assistant), an ArcPad extension for geologic mapping: code, prerequisites, and instructions

    USGS Publications Warehouse

    ,

    2006-01-01

    GDA (Geologic Data Assistant) is an extension to ArcPad, a mobile mapping software program by Environmental Systems Research Institute (ESRI) designed to run on personal digital assistant (PDA) computers. GDA and ArcPad allow a PDA to replace the paper notebook and field map traditionally used for geologic mapping. GDA allows easy collection of field data.

  5. Design space exploration of high throughput finite field multipliers for channel coding on Xilinx FPGAs

    NASA Astrophysics Data System (ADS)

    de Schryver, C.; Weithoffer, S.; Wasenmüller, U.; Wehn, N.

    2012-09-01

    Channel coding is a standard technique in all wireless communication systems. In addition to the typically employed methods like convolutional coding, turbo coding or low density parity check (LDPC) coding, algebraic codes are used in many cases. For example, outer BCH coding is applied in the DVB-S2 standard for satellite TV broadcasting. A key operation for BCH and the related Reed-Solomon codes are multiplications in finite fields (Galois Fields), where extension fields of prime fields are used. A lot of architectures for multiplications in finite fields have been published over the last decades. This paper examines four different multiplier architectures in detail that offer the potential for very high throughputs. We investigate the implementation performance of these multipliers on FPGA technology in the context of channel coding. We study the efficiency of the multipliers with respect to area, frequency and throughput, as well as configurability and scalability. The implementation data of the fully verified circuits are provided for a Xilinx Virtex-4 device after place and route.

  6. Statistical Analysis of CFD Solutions from the Third AIAA Drag Prediction Workshop

    NASA Technical Reports Server (NTRS)

    Morrison, Joseph H.; Hemsch, Michael J.

    2007-01-01

    The first AIAA Drag Prediction Workshop, held in June 2001, evaluated the results from an extensive N-version test of a collection of Reynolds-Averaged Navier-Stokes CFD codes. The code-to-code scatter was more than an order of magnitude larger than desired for design and experimental validation of cruise conditions for a subsonic transport configuration. The second AIAA Drag Prediction Workshop, held in June 2003, emphasized the determination of installed pylon-nacelle drag increments and grid refinement studies. The code-to-code scatter was significantly reduced compared to the first DPW, but still larger than desired. However, grid refinement studies showed no significant improvement in code-to-code scatter with increasing grid refinement. The third Drag Prediction Workshop focused on the determination of installed side-of-body fairing drag increments and grid refinement studies for clean attached flow on wing alone configurations and for separated flow on the DLR-F6 subsonic transport model. This work evaluated the effect of grid refinement on the code-to-code scatter for the clean attached flow test cases and the separated flow test cases.

  7. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Moses, Haifa

    2016-01-01

    Speech alarms have been used extensively in aviation and included in International Building Codes (IBC) and National Fire Protection Association's (NFPA) Life Safety Code. However, they have not been implemented on space vehicles. Previous studies conducted at NASA JSC showed that speech alarms lead to faster identification and higher accuracy. This research evaluated updated speech and tone alerts in a laboratory environment and in the Human Exploration Research Analog (HERA) in a realistic setup.

  8. Extending Mondrian Memory Protection

    DTIC Science & Technology

    2010-11-01

    a kernel semaphore is locked or unlocked. In addition, we extended the system call interface to receive notifications about user-land locking...operations (such as calls to the mutex and semaphore code provided by the C library). By patching the dynamically loadable GLibC5, we are able to test... semaphores , and spinlocks. RTO-MP-IST-091 10- 9 Extending Mondrian Memory Protection to loading extension plugins. This prevents any untrusted code

  9. Unsteady transonic viscous-inviscid interaction using Euler and boundary-layer equations

    NASA Technical Reports Server (NTRS)

    Pirzadeh, Shahyar; Whitfield, Dave

    1989-01-01

    The Euler code is used extensively for computation of transonic unsteady aerodynamics. The boundary layer code solves the 3-D, compressible, unsteady, mean flow kinetic energy integral boundary layer equations in the direct mode. Inviscid-viscous coupling is handled using porosity boundary conditions. Some of the advantages and disadvantages of using the Euler and boundary layer equations for investigating unsteady viscous-inviscid interaction is examined.

  10. Study of coherent synchrotron radiation effects by means of a new simulation code based on the non-linear extension of the operator splitting method

    NASA Astrophysics Data System (ADS)

    Dattoli, G.; Migliorati, M.; Schiavi, A.

    2007-05-01

    The coherent synchrotron radiation (CSR) is one of the main problems limiting the performance of high-intensity electron accelerators. The complexity of the physical mechanisms underlying the onset of instabilities due to CSR demands for accurate descriptions, capable of including the large number of features of an actual accelerating device. A code devoted to the analysis of these types of problems should be fast and reliable, conditions that are usually hardly achieved at the same time. In the past, codes based on Lie algebraic techniques have been very efficient to treat transport problems in accelerators. The extension of these methods to the non-linear case is ideally suited to treat CSR instability problems. We report on the development of a numerical code, based on the solution of the Vlasov equation, with the inclusion of non-linear contribution due to wake field effects. The proposed solution method exploits an algebraic technique that uses the exponential operators. We show that the integration procedure is capable of reproducing the onset of instability and the effects associated with bunching mechanisms leading to the growth of the instability itself. In addition, considerations on the threshold of the instability are also developed.

  11. Development of an LSI maximum-likelihood convolutional decoder for advanced forward error correction capability on the NASA 30/20 GHz program

    NASA Technical Reports Server (NTRS)

    Clark, R. T.; Mccallister, R. D.

    1982-01-01

    The particular coding option identified as providing the best level of coding gain performance in an LSI-efficient implementation was the optimal constraint length five, rate one-half convolutional code. To determine the specific set of design parameters which optimally matches this decoder to the LSI constraints, a breadboard MCD (maximum-likelihood convolutional decoder) was fabricated and used to generate detailed performance trade-off data. The extensive performance testing data gathered during this design tradeoff study are summarized, and the functional and physical MCD chip characteristics are presented.

  12. Rapid Assessment of Agility for Conceptual Design Synthesis

    NASA Technical Reports Server (NTRS)

    Biezad, Daniel J.

    1996-01-01

    This project consists of designing and implementing a real-time graphical interface for a workstation-based flight simulator. It is capable of creating a three-dimensional out-the-window scene of the aircraft's flying environment, with extensive information about the aircraft's state displayed in the form of a heads-up-display (HUD) overlay. The code, written in the C programming language, makes calls to Silicon Graphics' Graphics Library (GL) to draw the graphics primitives. Included in this report is a detailed description of the capabilities of the code, including graphical examples, as well as a printout of the code itself

  13. Fast H.264/AVC FRExt intra coding using belief propagation.

    PubMed

    Milani, Simone

    2011-01-01

    In the H.264/AVC FRExt coder, the coding performance of Intra coding significantly overcomes the previous still image coding standards, like JPEG2000, thanks to a massive use of spatial prediction. Unfortunately, the adoption of an extensive set of predictors induces a significant increase of the computational complexity required by the rate-distortion optimization routine. The paper presents a complexity reduction strategy that aims at reducing the computational load of the Intra coding with a small loss in the compression performance. The proposed algorithm relies on selecting a reduced set of prediction modes according to their probabilities, which are estimated adopting a belief-propagation procedure. Experimental results show that the proposed method permits saving up to 60 % of the coding time required by an exhaustive rate-distortion optimization method with a negligible loss in performance. Moreover, it permits an accurate control of the computational complexity unlike other methods where the computational complexity depends upon the coded sequence.

  14. Tiltrotor Aeroacoustic Code (TRAC) Prediction Assessment and Initial Comparisons with Tram Test Data

    NASA Technical Reports Server (NTRS)

    Burley, Casey L.; Brooks, Thomas F.; Charles, Bruce D.; McCluer, Megan

    1999-01-01

    A prediction sensitivity assessment to inputs and blade modeling is presented for the TiltRotor Aeroacoustic Code (TRAC). For this study, the non-CFD prediction system option in TRAC is used. Here, the comprehensive rotorcraft code, CAMRAD.Mod1, coupled with the high-resolution sectional loads code HIRES, predicts unsteady blade loads to be used in the noise prediction code WOPWOP. The sensitivity of the predicted blade motions, blade airloads, wake geometry, and acoustics is examined with respect to rotor rpm, blade twist and chord, and to blade dynamic modeling. To accomplish this assessment, an interim input-deck for the TRAM test model and an input-deck for a reference test model are utilized in both rigid and elastic modes. Both of these test models are regarded as near scale models of the V-22 proprotor (tiltrotor). With basic TRAC sensitivities established, initial TRAC predictions are compared to results of an extensive test of an isolated model proprotor. The test was that of the TiltRotor Aeroacoustic Model (TRAM) conducted in the Duits-Nederlandse Windtunnel (DNW). Predictions are compared to measured noise for the proprotor operating over an extensive range of conditions. The variation of predictions demonstrates the great care that must be taken in defining the blade motion. However, even with this variability, the predictions using the different blade modeling successfully capture (bracket) the levels and trends of the noise for conditions ranging from descent to ascent.

  15. Tiltrotor Aeroacoustic Code (TRAC) Prediction Assessment and Initial Comparisons With TRAM Test Data

    NASA Technical Reports Server (NTRS)

    Burley, Casey L.; Brooks, Thomas F.; Charles, Bruce D.; McCluer, Megan

    1999-01-01

    A prediction sensitivity assessment to inputs and blade modeling is presented for the TiltRotor Aeroacoustic Code (TRAC). For this study, the non-CFD prediction system option in TRAC is used. Here, the comprehensive rotorcraft code, CAMRAD.Mod 1, coupled with the high-resolution sectional loads code HIRES, predicts unsteady blade loads to be used in the noise prediction code WOPWOP. The sensitivity of the predicted blade motions, blade airloads, wake geometry, and acoustics is examined with respect to rotor rpm, blade twist and chord, and to blade dynamic modeling. To accomplish this assessment. an interim input-deck for the TRAM test model and an input-deck for a reference test model are utilized in both rigid and elastic modes. Both of these test models are regarded as near scale models of the V-22 proprotor (tiltrotor). With basic TRAC sensitivities established, initial TRAC predictions are compared to results of an extensive test of an isolated model proprotor. The test was that of the TiltRotor Aeroacoustic Model (TRAM) conducted in the Duits-Nederlandse Windtunnel (DNW). Predictions are compared to measured noise for the proprotor operating over an extensive range of conditions. The variation of predictions demonstrates the great care that must be taken in defining the blade motion. However, even with this variability, the predictions using the different blade modeling successfully capture (bracket) the levels and trends of the noise for conditions ranging from descent to ascent.

  16. Summary of papers on current and anticipated uses of thermal-hydraulic codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caruso, R.

    1997-07-01

    The author reviews a range of recent papers which discuss possible uses and future development needs for thermal/hydraulic codes in the nuclear industry. From this review, eight common recommendations are extracted. They are: improve the user interface so that more people can use the code, so that models are easier and less expensive to prepare and maintain, and so that the results are scrutable; design the code so that it can easily be coupled to other codes, such as core physics, containment, fission product behaviour during severe accidents; improve the numerical methods to make the code more robust and especiallymore » faster running, particularly for low pressure transients; ensure that future code development includes assessment of code uncertainties as integral part of code verification and validation; provide extensive user guidelines or structure the code so that the `user effect` is minimized; include the capability to model multiple fluids (gas and liquid phase); design the code in a modular fashion so that new models can be added easily; provide the ability to include detailed or simplified component models; build on work previously done with other codes (RETRAN, RELAP, TRAC, CATHARE) and other code validation efforts (CSAU, CSNI SET and IET matrices).« less

  17. Development of an Aeroelastic Code Based on an Euler/Navier-Stokes Aerodynamic Solver

    NASA Technical Reports Server (NTRS)

    Bakhle, Milind A.; Srivastava, Rakesh; Keith, Theo G., Jr.; Stefko, George L.; Janus, Mark J.

    1996-01-01

    This paper describes the development of an aeroelastic code (TURBO-AE) based on an Euler/Navier-Stokes unsteady aerodynamic analysis. A brief review of the relevant research in the area of propulsion aeroelasticity is presented. The paper briefly describes the original Euler/Navier-Stokes code (TURBO) and then details the development of the aeroelastic extensions. The aeroelastic formulation is described. The modeling of the dynamics of the blade using a modal approach is detailed, along with the grid deformation approach used to model the elastic deformation of the blade. The work-per-cycle approach used to evaluate aeroelastic stability is described. Representative results used to verify the code are presented. The paper concludes with an evaluation of the development thus far, and some plans for further development and validation of the TURBO-AE code.

  18. Nasal versus oronasal raised volume forced expirations in infants – A real physiologic challenge

    PubMed Central

    Morris, Mohy G.

    2012-01-01

    Summary Raised volume rapid thoracoabdominal compression (RTC) generates forced expiration (FE) in infants typically from an airway opening pressure of 30 cm H2O (V30). We hypothesized that the higher nasal than pulmonary airway resistance limits forced expiratory flows (FEF%) during (nasal) FEn, which an opened mouth, (oronasal) FEo, would resolve. Measurements were performed during a brief post-hyperventilation apnea on twelve healthy infants aged 6.9–104 weeks. In two infants, forced expiratory (FEFV) flow volume (FV) curves were generated using a facemask that covered the nose and a closed mouth, then again with a larger mask with the mouth opened. In other infants (n=10), the mouth closed spontaneously during FE. Oronasal passive expiration from V30 generated either the inspiratory capacity (IC) or by activating RTC before end-expiration, the slow vital capacity (jSVC). Peak flow (PF), FEF25, FEF50, FEF25–75, FEV0.4 and FEV0.5 were lower via FEn than FEo (p<0.05), but the ratio of expired volume at PF and forced vital capacity (FVC) as percent was higher (p<0.05). FEF75, FEF85, FEF90, FVC as well as the applied jacket pressures were not different (p>0.05). FEFV curves generated via FEo exhibited higher PF than FV curves of IC (p< 0.05); PF of those produced via FEn were not different from FV curves of IC (p> 0.05) but lower than those of jSVC (p< 0.05). In conclusion, the higher nasal than pulmonary airways resistance unequivocally affects the FEFV curves by consistently reducing PF and decreases mid-expiratory flows. A monitored slightly opened mouth and a gentle anterior jaw thrust are physiologically integral for raised volume RTC in order to maximize the oral and minimize nasal airways contribution to FE so that flow limitation would be in the pulmonary not nasal airways. PMID:22328241

  19. SU-E-J-100: The Combination of Deformable Image Registration and Regions-Of-Interest Mapping Technique to Accomplish Accurate Dose Calculation On Cone Beam Computed Tomography for Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, B-T; Lu, J-Y

    Purpose: We introduce a new method combined with the deformable image registration (DIR) and regions-of-interest mapping (ROIM) technique to accurately calculate dose on daily CBCT for esophageal cancer. Methods: Patients suffered from esophageal cancer were enrolled in the study. Prescription was set to 66 Gy/30 F and 54 Gy/30 F to the primary tumor (PTV66) and subclinical disease (PTV54) . Planning CT (pCT) were segmented into 8 substructures in terms of their differences in physical density, such as gross target volume (GTV), venae cava superior (SVC), aorta, heart, spinal cord, lung, muscle and bones. The pCT and its substructures weremore » transferred to the MIM software to readout their mean HU values. Afterwards, a deformable planning CT to daily KV-CBCT image registration method was then utilized to acquire a new structure set on CBCT. The newly generated structures on CBCT were then transferred back to the treatment planning system (TPS) and its HU information were overridden manually with mean HU values obtained from pCT. Finally, the treatment plan was projected onto the CBCT images with the same beam arrangements and monitor units (MUs) to accomplish dose calculation. Planning target volume (PTV) and organs at risk (OARs) from both of the pCT and CBCT were compared to evaluate the dose calculation accuracy. Results: It was found that the dose distribution in the CBCT showed little differences compared to the pCT, regardless of whether PTV or OARs were concerned. Specifically, dose variation in GTV, PTV54, PTV66, SVC, lung and heart were within 0.1%. The maximum dose variation was presented in the spinal cord, which was up to 2.7% dose difference. Conclusion: The proposed method combined with DIR and ROIM technique to accurately calculate dose distribution on CBCT for esophageal cancer is feasible.« less

  20. A pharmaco-metabolomics approach in a clinical trial of ALS: Identification of predictive markers of progression.

    PubMed

    Blasco, Hélène; Patin, Franck; Descat, Amandine; Garçon, Guillaume; Corcia, Philippe; Gelé, Patrick; Lenglet, Timothée; Bede, Peter; Meininger, Vincent; Devos, David; Gossens, Jean François; Pradat, Pierre-François

    2018-01-01

    There is an urgent and unmet need for accurate biomarkers in Amyotrophic Lateral Sclerosis. A pharmaco-metabolomics study was conducted using plasma samples from the TRO19622 (olesoxime) trial to assess the link between early metabolomic profiles and clinical outcomes. Patients included in this trial were randomized into either Group O receiving olesoxime (n = 38) or Group P receiving placebo (n = 36). The metabolomic profile was assessed at time-point one (V1) and 12 months (V12) after the initiation of the treatment. High performance liquid chromatography coupled with tandem mass spectrometry was used to quantify 188 metabolites (Biocrates® commercial kit). Multivariate analysis based on machine learning approaches (i.e. Biosigner algorithm) was performed. Metabolomic profiles at V1 and V12 and changes in metabolomic profiles between V1 and V12 accurately discriminated between Groups O and P (p<5×10-6), and identified glycine, kynurenine and citrulline/arginine as the best predictors of group membership. Changes in metabolomic profiles were closely linked to clinical progression, and correlated with glutamine levels in Group P and amino acids, lipids and spermidine levels in Group O. Multivariate models accurately predicted disease progression and highlighted the discriminant role of sphingomyelins (SM C22:3, SM C24:1, SM OH C22:2, SM C16:1). To predict SVC from SM C24:1 in group O and SVC from SM OH C22:2 and SM C16:1 in group P+O, we noted a median sensitivity between 67% and 100%, a specificity between 66.7 and 71.4%, a positive predictive value between 66 and 75% and a negative predictive value between 70% and 100% in the test sets. This proof-of-concept study demonstrates that the metabolomics has a role in evaluating the biological effect of an investigational drug and may be a candidate biomarker as a secondary outcome measure in clinical trials.

  1. Vertically acquired hepatitis C virus infection: Correlates of transmission and disease progression.

    PubMed

    Tovo, Pier-Angelo; Calitri, Carmelina; Scolfaro, Carlo; Gabiano, Clara; Garazzino, Silvia

    2016-01-28

    The worldwide prevalence of hepatitis C virus (HCV) infection in children is 0.05%-0.4% in developed countries and 2%-5% in resource-limited settings, where inadequately tested blood products or un-sterile medical injections still remain important routes of infection. After the screening of blood donors, mother-to-child transmission (MTCT) of HCV has become the leading cause of pediatric infection, at a rate of 5%. Maternal HIV co-infection is a significant risk factor for MTCT and anti-HIV therapy during pregnancy seemingly can reduce the transmission rate of both viruses. Conversely, a high maternal viral load is an important, but not preventable risk factor, because at present no anti-HCV treatment can be administered to pregnant women to block viral replication. Caution is needed in adopting obstetric procedures, such as amniocentesis or internal fetal monitoring, that can favor fetal exposure to HCV contaminated maternal blood, though evidence is lacking on the real risk of single obstetric practices. Mode of delivery and type of feeding do not represent significant risk factors for MTCT. Therefore, there is no reason to offer elective caesarean section or discourage breast-feeding to HCV infected parturients. Information on the natural history of vertical HCV infection is limited. The primary infection is asymptomatic in infants. At least one quarter of infected children shows a spontaneous viral clearance (SVC) that usually occurs within 6 years of life. IL-28B polymorphims and genotype 3 infection have been associated with greater chances of SVC. In general, HCV progression is mild or moderate in children with chronic infection who grow regularly, though cases with marked liver fibrosis or hepatic failure have been described. Non-organ specific autoantibodies and cryoglobulins are frequently found in children with chronic infection, but autoimmune diseases or HCV associated extrahepatic manifestations are rare.

  2. Origin and ablation of the adenosine triphosphate induced atrial fibrillation after circumferential pulmonary vein isolation: effects on procedural success rate.

    PubMed

    Zhang, Jinlin; Tang, Cheng; Zhang, Yonghua; Su, X I

    2014-04-01

    Adenosine triphosphate (ATP) has been used to provoke dormant pulmonary vein (PV) conduction after circumferential PV isolation (CPVI). However, there have been no systematic studies examining the incidence and the mechanism of ATP-induced atrial fibrillation (AF) following CPVI in paroxysmal AF. In this study, we explore the mechanism of ATP-induced AF and assess the feasibility of eliminating this response by additional radiofrequency (RF) ablation. A total of 300 consecutive patients with paroxysmal AF underwent CPVI. After all PVs were isolated, intravenous ATP (40 mg) was administered during an intravenous isoproterenol (ISP) infusion (5 μg/min). AF was reproducibly induced by ATP in 39 patients. Non-PV foci were confirmed and located in 29 of these patients at the onset of AF, including 27 foci in the superior vena cava (SVC), 1 focus in the crista terminalis, and 1 focus near the antrum of the PV. In all these cases, ATP-induced AF was eliminated after the non-PV foci were successfully ablated. For the other 10 patients, the foci triggering AF could not be confirmed or located due to the transient effect of ATP, thus no further ablation was performed. After a mean follow-up period of 18.7 ± 6.4 (8-24) months, the success rate in the ATP-induced AF group was not significantly different compared with the conventional treatment group who did not exhibit ATP-induced AF (76.9% vs 67.3%; P = 0.25). But in the subgroup of which the ATP-induced AF could be eliminated by additional RF ablation, the success rate was significantly higher than the non-ATP inducible group (86.2% vs 67.3%; P = 0.04). A large proportion of the ATP-induced AF post CPVI were initiated by rapid firing in the SVC. Eliminating this response by additional ablation may have an influence on clinical results of paroxysmal AF ablation. © 2014 Wiley Periodicals, Inc.

  3. Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome.

    PubMed

    Aquilano, Giulia; Galletti, Silvia; Aceti, Arianna; Vitali, Francesca; Faldella, Giacomo

    2014-06-21

    Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. To assess changes in central blood flow in infants with respiratory distress syndrome (RDS) during bi-level CPAP support. A prospective study was performed in a cohort of 18 Very-Low-Birth-Weight Infants who were put on nasal CPAP support (4-5 cmH2O) because they developed RDS within the first 24-72 hours of life. Each subject was switched to bi-level CPAP support (Phigh 8 cmH2O, Plow 4-5 cmH2O, Thigh 0.5-0.6 seconds, 20 breaths/min) for an hour. An echocardiographic study and a capillary gas analysis were performed before and after the change of respiratory support. No differences between n-CPAP and bi-level CPAP in left ventricular output (LVO, 222.17 ± 81.4 vs 211.4 ± 75.3 ml/kg/min), right ventricular output (RVO, 287.8 ± 96 vs 283.4 ± 87.4 ml/kg/min) and superior vena cava flow (SVC, 135.38 ± 47.8 vs 137.48 ± 46.6 ml/kg/min) were observed. The hemodynamic characteristics of the ductus arteriosus were similar. A significant decrease in pCO2 levels after bi-level CPAP ventilation was observed; pCO2 variations did not correlate with modifications of central blood flow (LVO: ρ=0.11, p=0,657; RVO: ρ=-0.307, p=0.216; SVC: ρ=-0.13, p=0.197). Central blood flow doesn't change during bi-level CPAP support, which could become a hemodinamically safe tool for the treatment of RDS in preterm infants.

  4. [Prevalence of stenosis and thrombosis of central veins in hemodialysis after a tunneled jugular catheter].

    PubMed

    Jean, G; Vanel, T; Chazot, C; Charra, B; Terrat, J C; Hurot, J M

    2001-01-01

    Central venous stenosis (ST) and thrombosis (TB) related to catheter (KT) had been reported mostly for the subclavian vein. We performed a systematic cavographic study to evaluate the prevalence of these complications in 51 hemodialysis patients with present or previous history of tunneled internal jugular catheter. Each of them had used one or several KT (1.8 +/- 1.4 KT) for a mean 28 +/- 26 month cumulative time (i.e. 43,584 days total exposure time). Fifty percent of the KT were PermCath Quinton and 50% were Twincath (uncuffed) or CS 100 (cuffed) Medcomp. Twenty-seven had no ST (53%, group I), 24 had one or several significant ST (47%, group II) of superior Vena Cava (SVC, n = 4), inferior Vena Cava (IVC, n = 1), Brachio-cephalic Vein (BCV, n = 5) and subclavian vein (SC, n = 10), or a TB of SVC (n = 1), IVC (n = 3), BCV (n = 3), SC (n = 2). This accounts for an incidence of 0.55 ST or TB/1000 patient-days. Five of the twelve subclavian ST and TB had no history of previous subclavian catheter. Comparison between the two groups showed no differences according to age, time on dialysis, diabetes, hematocrit, CRP, cumulative time with catheter, catheter-related infections, type of catheter and anticoagulant treatment. IVC catheter tip's position is an important risk factor for TB and ST (4/6). Twelve group II patients had ST or TB-related symptoms, with a functional AV fistula in 9 cases. Eleven patients underwent repeated percutaneous angioplasty with 4 additional Wallstents and in 2 cases an AV fistula need to be closed. Central venous ST and TB after a jugular KT is extremely frequent, mostly without any symptoms. Consequences on peripheral or central vascular access, cost and poor long-term patency rate of angioplasty are of major importance. These results incite us to further reduce the catheter use in dialysis patients.

  5. Cord milking versus immediate clamping in preterm infants: a randomised controlled trial.

    PubMed

    El-Naggar, Walid; Simpson, David; Hussain, Arif; Armson, Anthony; Dodds, Linda; Warren, Andrew; Whyte, Robin; McMillan, Douglas

    2018-06-14

    To investigate whether umbilical cord milking (UCM) at birth improves systemic blood flow and short-term outcomes, as compared with immediate cord clamping (ICC). Randomised clinical trial. Single tertiary care centre. Infants born to eligible women presenting in preterm labour between 24 and 31 weeks' gestation. UCM three times at birth or ICC. Primary outcome included systemic blood flow as represented by echo-derived superior vena cava(SVC) flow at 4-6 hours after birth. The echocardiographer and interpreter were blinded to the randomisation. Secondary outcomes included cardiac output, neonatal morbidities and mortality. Analysis was by intention to treat. A total of 73 infants were randomised (37 to UCM and 36 to ICC). Mean (SD) gestational age was 27 (2) weeks and mean (SD) birth weight was 1040 (283) g. Haemoglobin on admission was higher in the UCM than in the ICC group (16.1 vs 15.0 g/L), p=0.049 (mean difference 1.1, 95% CI 0.003 to 2.2). No statistically significant differences were found between groups in SVC flow at 4-6 hours (88.9±37.8 and 107.3±60.1 mL/kg/min), p=0.13 (mean difference -18.4, 95% CI -41.7 to 5.0 mL/kg/min) or at 10-12 hours of age (102.5±41.8 and 90.6±28.4 mL/kg/min), p=0.17 (mean difference 12.0, 95% CI -4.7 to 28.7 mL/kg/min), cardiac output or neonatal morbidities. Cord milking was not shown to improve functional cardiac outcomes, neonatal morbidity or mortality. More research is needed before routine cord milking can be recommended for very preterm infants. NCT01487187. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Change in working characteristics of the steam turbine metal with operating time of more than 330000 hours

    NASA Astrophysics Data System (ADS)

    Gladshteyn, V. I.; Troitskiy, A. I.

    2017-01-01

    Research of a metal of the stop valve case (SVC) of the K-300-23.5 LMZ turbine (steel grade 15Kh1M1FL), destroyed after operation for 331000 hours, is performed. It's chemical composition and properties are determined as follows: a short-term mechanical tensile stress at 20°C and at elevated temperature, critical temperature, fragility, critical crack opening at elevated temperature, and long-term strength. Furthermore, nature of the microstructure, packing density of carbide particles and their size, and chemical composition of carbide sediment are estimated. A manifestation of metal properties for the main case components by comparison with a forecast of the respective characteristics made for the operating time of 331000 hours is tested. Property-time relationships are built for the forecast using statistical treatment of the test results for the samples cut out from more than 300 parts. Representativeness of the research results is proved: the statistical treatment of their differences are within the range of ±5%. It has been found that, after 150000 hours of operation, only the tensile strength insignificantly depends on the operating time at 20°C, whereas indicators of strength at elevated temperature significantly reduce, depending on the operating time. A brittle-to-ductile transition temperature (BDTT) raises, a critical notch opening changes in a complicated way, a long-term strength reduces. It has been found empirically that the limit of a long-term strength of the SVC metal at 540°C and the operating time of 105 hours is almost 1.6 times less than the required value in the as-delivered state. It is possible to evaluate a service life of the operating valves with the operating time of more than 330000 hours with respect to the long-term strength of the metal taking into account the actual temperature and stress. Guidelines for the control of similar parts are provided.

  7. Team Software Development for Aerothermodynamic and Aerodynamic Analysis and Design

    NASA Technical Reports Server (NTRS)

    Alexandrov, N.; Atkins, H. L.; Bibb, K. L.; Biedron, R. T.; Carpenter, M. H.; Gnoffo, P. A.; Hammond, D. P.; Jones, W. T.; Kleb, W. L.; Lee-Rausch, E. M.

    2003-01-01

    A collaborative approach to software development is described. The approach employs the agile development techniques: project retrospectives, Scrum status meetings, and elements of Extreme Programming to efficiently develop a cohesive and extensible software suite. The software product under development is a fluid dynamics simulator for performing aerodynamic and aerothermodynamic analysis and design. The functionality of the software product is achieved both through the merging, with substantial rewrite, of separate legacy codes and the authorship of new routines. Examples of rapid implementation of new functionality demonstrate the benefits obtained with this agile software development process. The appendix contains a discussion of coding issues encountered while porting legacy Fortran 77 code to Fortran 95, software design principles, and a Fortran 95 coding standard.

  8. Computational Nuclear Physics and Post Hartree-Fock Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lietz, Justin; Sam, Novario; Hjorth-Jensen, M.

    We present a computational approach to infinite nuclear matter employing Hartree-Fock theory, many-body perturbation theory and coupled cluster theory. These lectures are closely linked with those of chapters 9, 10 and 11 and serve as input for the correlation functions employed in Monte Carlo calculations in chapter 9, the in-medium similarity renormalization group theory of dense fermionic systems of chapter 10 and the Green's function approach in chapter 11. We provide extensive code examples and benchmark calculations, allowing thereby an eventual reader to start writing her/his own codes. We start with an object-oriented serial code and end with discussions onmore » strategies for porting the code to present and planned high-performance computing facilities.« less

  9. \\Space: A new code to estimate \\temp, \\logg, and elemental abundances

    NASA Astrophysics Data System (ADS)

    Boeche, C.

    2016-09-01

    \\Space is a FORTRAN95 code that derives stellar parameters and elemental abundances from stellar spectra. To derive these parameters, \\Space does not measure equivalent widths of lines nor it uses templates of synthetic spectra, but it employs a new method based on a library of General Curve-Of-Growths. To date \\Space works on the wavelength range 5212-6860 Å and 8400-8921 Å, and at the spectral resolution R=2000-20000. Extensions of these limits are possible. \\Space is a highly automated code suitable for application to large spectroscopic surveys. A web front end to this service is publicly available at http://dc.g-vo.org/SP_ACE together with the library and the binary code.

  10. Analysis of view synthesis prediction architectures in modern coding standards

    NASA Astrophysics Data System (ADS)

    Tian, Dong; Zou, Feng; Lee, Chris; Vetro, Anthony; Sun, Huifang

    2013-09-01

    Depth-based 3D formats are currently being developed as extensions to both AVC and HEVC standards. The availability of depth information facilitates the generation of intermediate views for advanced 3D applications and displays, and also enables more efficient coding of the multiview input data through view synthesis prediction techniques. This paper outlines several approaches that have been explored to realize view synthesis prediction in modern video coding standards such as AVC and HEVC. The benefits and drawbacks of various architectures are analyzed in terms of performance, complexity, and other design considerations. It is hence concluded that block-based VSP prediction for multiview video signals provides attractive coding gains with comparable complexity as traditional motion/disparity compensation.

  11. Axon-Sorting Multifunctional Nerve Guides: Accelerating Restoration of Nerve Function

    DTIC Science & Technology

    2014-10-01

    factor (singly & in selected combinations) in the organotypic model system for preferential sensory or motor axon extension. Use confocal microscopy to...track axon extension of labeled sensory or motor neurons from spinal cord slices (motor) or dorsal root ganglia ( DRG ) (sensory). 20 Thy1-YFP mice...RESEARCH ACCOMPLISHMENTS: • Established a system of color-coded mixed nerve tracking using GFP and RFP expressing motor and sensory neurons (Figure 1

  12. Automatic Multilevel Parallelization Using OpenMP

    NASA Technical Reports Server (NTRS)

    Jin, Hao-Qiang; Jost, Gabriele; Yan, Jerry; Ayguade, Eduard; Gonzalez, Marc; Martorell, Xavier; Biegel, Bryan (Technical Monitor)

    2002-01-01

    In this paper we describe the extension of the CAPO (CAPtools (Computer Aided Parallelization Toolkit) OpenMP) parallelization support tool to support multilevel parallelism based on OpenMP directives. CAPO generates OpenMP directives with extensions supported by the NanosCompiler to allow for directive nesting and definition of thread groups. We report some results for several benchmark codes and one full application that have been parallelized using our system.

  13. Applying a Service-Oriented Architecture to Operational Flight Program Development

    DTIC Science & Technology

    2007-09-01

    using two Java 2 Enterprise Edition (J2EE) Web servers. The weapon models were accessed using a SUN Microsystems Java Web Services Development Pack...Oriented Architectures 22 CROSSTALK The Journal of Defense Software Engineering September 2007 tion, and Spring/ Hibernate to provide the data access...tion since a major coding effort was avoided. The majority of the effort was tweaking pre-existing Java source code and editing of eXtensible Markup

  14. The chemical basis for the origin of the genetic code and the process of protein synthesis

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The principles upon which the process of protein synthesis and the genetic code were established are elucidated. Extensive work on nuclear magnetic resonance studies of both monomermonomer and monoamino acid polynucleotide interactions is included. A new method of general utility for studying any amino acid interacting with any polynucleotide was developed. This system involves the use of methyl esters of amino acids interacting with polynucleotides.

  15. LeRC-HT: NASA Lewis Research Center General Multiblock Navier-Stokes Heat Transfer Code Developed

    NASA Technical Reports Server (NTRS)

    Heidmann, James D.; Gaugler, Raymond E.

    1999-01-01

    For the last several years, LeRC-HT, a three-dimensional computational fluid dynamics (CFD) computer code for analyzing gas turbine flow and convective heat transfer, has been evolving at the NASA Lewis Research Center. The code is unique in its ability to give a highly detailed representation of the flow field very close to solid surfaces. This is necessary for an accurate representation of fluid heat transfer and viscous shear stresses. The code has been used extensively for both internal cooling passage flows and hot gas path flows--including detailed film cooling calculations, complex tip-clearance gap flows, and heat transfer. In its current form, this code has a multiblock grid capability and has been validated for a number of turbine configurations. The code has been developed and used primarily as a research tool (at least 35 technical papers have been published relative to the code and its application), but it should be useful for detailed design analysis. We now plan to make this code available to selected users for further evaluation.

  16. Recent research in network problems with applications

    NASA Technical Reports Server (NTRS)

    Thompson, G. L.

    1980-01-01

    The capabilities of network codes and their extensions are surveyed in regard to specially structured integer programming problems which are solved by using the solutions of a series of ordinary network problems.

  17. Design and implementation of a scene-dependent dynamically selfadaptable wavefront coding imaging system

    NASA Astrophysics Data System (ADS)

    Carles, Guillem; Ferran, Carme; Carnicer, Artur; Bosch, Salvador

    2012-01-01

    A computational imaging system based on wavefront coding is presented. Wavefront coding provides an extension of the depth-of-field at the expense of a slight reduction of image quality. This trade-off results from the amount of coding used. By using spatial light modulators, a flexible coding is achieved which permits it to be increased or decreased as needed. In this paper a computational method is proposed for evaluating the output of a wavefront coding imaging system equipped with a spatial light modulator, with the aim of thus making it possible to implement the most suitable coding strength for a given scene. This is achieved in an unsupervised manner, thus the whole system acts as a dynamically selfadaptable imaging system. The program presented here controls the spatial light modulator and the camera, and also processes the images in a synchronised way in order to implement the dynamic system in real time. A prototype of the system was implemented in the laboratory and illustrative examples of the performance are reported in this paper. Program summaryProgram title: DynWFC (Dynamic WaveFront Coding) Catalogue identifier: AEKC_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEKC_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 10 483 No. of bytes in distributed program, including test data, etc.: 2 437 713 Distribution format: tar.gz Programming language: Labview 8.5 and NI Vision and MinGW C Compiler Computer: Tested on PC Intel ® Pentium ® Operating system: Tested on Windows XP Classification: 18 Nature of problem: The program implements an enhanced wavefront coding imaging system able to adapt the degree of coding to the requirements of a specific scene. The program controls the acquisition by a camera, the display of a spatial light modulator and the image processing operations synchronously. The spatial light modulator is used to implement the phase mask with flexibility given the trade-off between depth-of-field extension and image quality achieved. The action of the program is to evaluate the depth-of-field requirements of the specific scene and subsequently control the coding established by the spatial light modulator, in real time.

  18. Box codes of lengths 48 and 72

    NASA Technical Reports Server (NTRS)

    Solomon, G.; Jin, Y.

    1993-01-01

    A self-dual code length 48, dimension 24, with Hamming distance essentially equal to 12 is constructed here. There are only six code words of weight eight. All the other code words have weights that are multiples of four and have a minimum weight equal to 12. This code may be encoded systematically and arises from a strict binary representation of the (8,4;5) Reed-Solomon (RS) code over GF (64). The code may be considered as six interrelated (8,7;2) codes. The Mattson-Solomon representation of the cyclic decomposition of these codes and their parity sums are used to detect an odd number of errors in any of the six codes. These may then be used in a correction algorithm for hard or soft decision decoding. A (72,36;15) box code was constructed from a (63,35;8) cyclic code. The theoretical justification is presented herein. A second (72,36;15) code is constructed from an inner (63,27;16) Bose Chaudhuri Hocquenghem (BCH) code and expanded to length 72 using box code algorithms for extension. This code was simulated and verified to have a minimum distance of 15 with even weight words congruent to zero modulo four. The decoding for hard and soft decision is still more complex than the first code constructed above. Finally, an (8,4;5) RS code over GF (512) in the binary representation of the (72,36;15) box code gives rise to a (72,36;16*) code with nine words of weight eight, and all the rest have weights greater than or equal to 16.

  19. A 3D-CFD code for accurate prediction of fluid flows and fluid forces in seals

    NASA Technical Reports Server (NTRS)

    Athavale, M. M.; Przekwas, A. J.; Hendricks, R. C.

    1994-01-01

    Current and future turbomachinery requires advanced seal configurations to control leakage, inhibit mixing of incompatible fluids and to control the rotodynamic response. In recognition of a deficiency in the existing predictive methodology for seals, a seven year effort was established in 1990 by NASA's Office of Aeronautics Exploration and Technology, under the Earth-to-Orbit Propulsion program, to develop validated Computational Fluid Dynamics (CFD) concepts, codes and analyses for seals. The effort will provide NASA and the U.S. Aerospace Industry with advanced CFD scientific codes and industrial codes for analyzing and designing turbomachinery seals. An advanced 3D CFD cylindrical seal code has been developed, incorporating state-of-the-art computational methodology for flow analysis in straight, tapered and stepped seals. Relevant computational features of the code include: stationary/rotating coordinates, cylindrical and general Body Fitted Coordinates (BFC) systems, high order differencing schemes, colocated variable arrangement, advanced turbulence models, incompressible/compressible flows, and moving grids. This paper presents the current status of code development, code demonstration for predicting rotordynamic coefficients, numerical parametric study of entrance loss coefficients for generic annular seals, and plans for code extensions to labyrinth, damping, and other seal configurations.

  20. Synthesizing Certified Code

    NASA Technical Reports Server (NTRS)

    Whalen, Michael; Schumann, Johann; Fischer, Bernd

    2002-01-01

    Code certification is a lightweight approach to demonstrate software quality on a formal level. Its basic idea is to require producers to provide formal proofs that their code satisfies certain quality properties. These proofs serve as certificates which can be checked independently. Since code certification uses the same underlying technology as program verification, it also requires many detailed annotations (e.g., loop invariants) to make the proofs possible. However, manually adding theses annotations to the code is time-consuming and error-prone. We address this problem by combining code certification with automatic program synthesis. We propose an approach to generate simultaneously, from a high-level specification, code and all annotations required to certify generated code. Here, we describe a certification extension of AUTOBAYES, a synthesis tool which automatically generates complex data analysis programs from compact specifications. AUTOBAYES contains sufficient high-level domain knowledge to generate detailed annotations. This allows us to use a general-purpose verification condition generator to produce a set of proof obligations in first-order logic. The obligations are then discharged using the automated theorem E-SETHEO. We demonstrate our approach by certifying operator safety for a generated iterative data classification program without manual annotation of the code.

  1. Collaborative Software Development in Support of Fast Adaptive AeroSpace Tools (FAAST)

    NASA Technical Reports Server (NTRS)

    Kleb, William L.; Nielsen, Eric J.; Gnoffo, Peter A.; Park, Michael A.; Wood, William A.

    2003-01-01

    A collaborative software development approach is described. The software product is an adaptation of proven computational capabilities combined with new capabilities to form the Agency's next generation aerothermodynamic and aerodynamic analysis and design tools. To efficiently produce a cohesive, robust, and extensible software suite, the approach uses agile software development techniques; specifically, project retrospectives, the Scrum status meeting format, and a subset of Extreme Programming's coding practices are employed. Examples are provided which demonstrate the substantial benefits derived from employing these practices. Also included is a discussion of issues encountered when porting legacy Fortran 77 code to Fortran 95 and a Fortran 95 coding standard.

  2. Coding, Constant Comparisons, and Core Categories: A Worked Example for Novice Constructivist Grounded Theorists.

    PubMed

    Giles, Tracey M; de Lacey, Sheryl; Muir-Cochrane, Eimear

    2016-01-01

    Grounded theory method has been described extensively in the literature. Yet, the varying processes portrayed can be confusing for novice grounded theorists. This article provides a worked example of the data analysis phase of a constructivist grounded theory study that examined family presence during resuscitation in acute health care settings. Core grounded theory methods are exemplified, including initial and focused coding, constant comparative analysis, memo writing, theoretical sampling, and theoretical saturation. The article traces the construction of the core category "Conditional Permission" from initial and focused codes, subcategories, and properties, through to its position in the final substantive grounded theory.

  3. Perceptually-Based Adaptive JPEG Coding

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Rosenholtz, Ruth; Null, Cynthia H. (Technical Monitor)

    1996-01-01

    An extension to the JPEG standard (ISO/IEC DIS 10918-3) allows spatial adaptive coding of still images. As with baseline JPEG coding, one quantization matrix applies to an entire image channel, but in addition the user may specify a multiplier for each 8 x 8 block, which multiplies the quantization matrix, yielding the new matrix for the block. MPEG 1 and 2 use much the same scheme, except there the multiplier changes only on macroblock boundaries. We propose a method for perceptual optimization of the set of multipliers. We compute the perceptual error for each block based upon DCT quantization error adjusted according to contrast sensitivity, light adaptation, and contrast masking, and pick the set of multipliers which yield maximally flat perceptual error over the blocks of the image. We investigate the bitrate savings due to this adaptive coding scheme and the relative importance of the different sorts of masking on adaptive coding.

  4. Competitive region orientation code for palmprint verification and identification

    NASA Astrophysics Data System (ADS)

    Tang, Wenliang

    2015-11-01

    Orientation features of the palmprint have been widely investigated in coding-based palmprint-recognition methods. Conventional orientation-based coding methods usually used discrete filters to extract the orientation feature of palmprint. However, in real operations, the orientations of the filter usually are not consistent with the lines of the palmprint. We thus propose a competitive region orientation-based coding method. Furthermore, an effective weighted balance scheme is proposed to improve the accuracy of the extracted region orientation. Compared with conventional methods, the region orientation of the palmprint extracted using the proposed method can precisely and robustly describe the orientation feature of the palmprint. Extensive experiments on the baseline PolyU and multispectral palmprint databases are performed and the results show that the proposed method achieves a promising performance in comparison to conventional state-of-the-art orientation-based coding methods in both palmprint verification and identification.

  5. 5D Tempest simulations of kinetic edge turbulence

    NASA Astrophysics Data System (ADS)

    Xu, X. Q.; Xiong, Z.; Cohen, B. I.; Cohen, R. H.; Dorr, M. R.; Hittinger, J. A.; Kerbel, G. D.; Nevins, W. M.; Rognlien, T. D.; Umansky, M. V.; Qin, H.

    2006-10-01

    Results are presented from the development and application of TEMPEST, a nonlinear five dimensional (3d2v) gyrokinetic continuum code. The simulation results and theoretical analysis include studies of H-mode edge plasma neoclassical transport and turbulence in real divertor geometry and its relationship to plasma flow generation with zero external momentum input, including the important orbit-squeezing effect due to the large electric field flow-shear in the edge. In order to extend the code to 5D, we have formulated a set of fully nonlinear electrostatic gyrokinetic equations and a fully nonlinear gyrokinetic Poisson's equation which is valid for both neoclassical and turbulence simulations. Our 5D gyrokinetic code is built on 4D version of Tempest neoclassical code with extension to a fifth dimension in binormal direction. The code is able to simulate either a full torus or a toroidal segment. Progress on performing 5D turbulence simulations will be reported.

  6. Method for coding low entrophy data

    NASA Technical Reports Server (NTRS)

    Yeh, Pen-Shu (Inventor)

    1995-01-01

    A method of lossless data compression for efficient coding of an electronic signal of information sources of very low information rate is disclosed. In this method, S represents a non-negative source symbol set, (s(sub 0), s(sub 1), s(sub 2), ..., s(sub N-1)) of N symbols with s(sub i) = i. The difference between binary digital data is mapped into symbol set S. Consecutive symbols in symbol set S are then paired into a new symbol set Gamma which defines a non-negative symbol set containing the symbols (gamma(sub m)) obtained as the extension of the original symbol set S. These pairs are then mapped into a comma code which is defined as a coding scheme in which every codeword is terminated with the same comma pattern, such as a 1. This allows a direct coding and decoding of the n-bit positive integer digital data differences without the use of codebooks.

  7. US Army Armor Reference Data in Three Volumes. Volume II. Nondivisional Organizations.

    DTIC Science & Technology

    1981-01-01

    SQuat 1r) R 2 SGI IB20 (Team Ldr) R I SP4 19GIO (Loader/Gnr) P I SP5 19G20 (St Gunner) P 1 t,5 19G20 (Sr Gunner) P I SP4 IICII ()Carrrr Dv) P 2 SP4 11810...Sergeant 2 SP4 Mat Storage Sp 1 SIC Platoon SOT1 SPC Food Svc SGT 1 SP4 Supply Con & Acct Cik 1 SP4 Lt Veh DriverI SFC Motor Sergeant I SP4 Subsistence...PLATOON Ho-.-- Loader Scoop Type 2-1/2 CU YD .Platoon Leader Tank Fabric Fuel 10,000-Gal. 1 SPC Platoon SC? 1 PFlC Reports Clerk 0lRadio Set N/VRC-46

  8. SKIRT: The design of a suite of input models for Monte Carlo radiative transfer simulations

    NASA Astrophysics Data System (ADS)

    Baes, M.; Camps, P.

    2015-09-01

    The Monte Carlo method is the most popular technique to perform radiative transfer simulations in a general 3D geometry. The algorithms behind and acceleration techniques for Monte Carlo radiative transfer are discussed extensively in the literature, and many different Monte Carlo codes are publicly available. On the contrary, the design of a suite of components that can be used for the distribution of sources and sinks in radiative transfer codes has received very little attention. The availability of such models, with different degrees of complexity, has many benefits. For example, they can serve as toy models to test new physical ingredients, or as parameterised models for inverse radiative transfer fitting. For 3D Monte Carlo codes, this requires algorithms to efficiently generate random positions from 3D density distributions. We describe the design of a flexible suite of components for the Monte Carlo radiative transfer code SKIRT. The design is based on a combination of basic building blocks (which can be either analytical toy models or numerical models defined on grids or a set of particles) and the extensive use of decorators that combine and alter these building blocks to more complex structures. For a number of decorators, e.g. those that add spiral structure or clumpiness, we provide a detailed description of the algorithms that can be used to generate random positions. Advantages of this decorator-based design include code transparency, the avoidance of code duplication, and an increase in code maintainability. Moreover, since decorators can be chained without problems, very complex models can easily be constructed out of simple building blocks. Finally, based on a number of test simulations, we demonstrate that our design using customised random position generators is superior to a simpler design based on a generic black-box random position generator.

  9. Additional extensions to the NASCAP computer code, volume 3

    NASA Technical Reports Server (NTRS)

    Mandell, M. J.; Cooke, D. L.

    1981-01-01

    The ION computer code is designed to calculate charge exchange ion densities, electric potentials, plasma temperatures, and current densities external to a neutralized ion engine in R-Z geometry. The present version assumes the beam ion current and density to be known and specified, and the neutralizing electrons to originate from a hot-wire ring surrounding the beam orifice. The plasma is treated as being resistive, with an electron relaxation time comparable to the plasma frequency. Together with the thermal and electrical boundary conditions described below and other straightforward engine parameters, these assumptions suffice to determine the required quantities. The ION code, written in ASCII FORTRAN for UNIVAC 1100 series computers, is designed to be run interactively, although it can also be run in batch mode. The input is free-format, and the output is mainly graphical, using the machine-independent graphics developed for the NASCAP code. The executive routine calls the code's major subroutines in user-specified order, and the code allows great latitude for restart and parameter change.

  10. The Athena Astrophysical MHD Code in Cylindrical Geometry

    NASA Astrophysics Data System (ADS)

    Skinner, M. A.; Ostriker, E. C.

    2011-10-01

    We have developed a method for implementing cylindrical coordinates in the Athena MHD code (Skinner & Ostriker 2010). The extension has been designed to alter the existing Cartesian-coordinates code (Stone et al. 2008) as minimally and transparently as possible. The numerical equations in cylindrical coordinates are formulated to maintain consistency with constrained transport, a central feature of the Athena algorithm, while making use of previously implemented code modules such as the eigensystems and Riemann solvers. Angular-momentum transport, which is critical in astrophysical disk systems dominated by rotation, is treated carefully. We describe modifications for cylindrical coordinates of the higher-order spatial reconstruction and characteristic evolution steps as well as the finite-volume and constrained transport updates. Finally, we have developed a test suite of standard and novel problems in one-, two-, and three-dimensions designed to validate our algorithms and implementation and to be of use to other code developers. The code is suitable for use in a wide variety of astrophysical applications and is freely available for download on the web.

  11. Extension of analog network coding in wireless information exchange

    NASA Astrophysics Data System (ADS)

    Chen, Cheng; Huang, Jiaqing

    2012-01-01

    Ever since the concept of analog network coding(ANC) was put forward by S.Katti, much attention has been focused on how to utilize analog network coding to take advantage of wireless interference, which used to be considered generally harmful, to improve throughput performance. Previously, only the case of two nodes that need to exchange information has been fully discussed while the issue of extending analog network coding to more than three nodes remains undeveloped. In this paper, we propose a practical transmission scheme to extend analog network coding to more than two nodes that need to exchange information among themselves. We start with the case of three nodes that need to exchange information and demonstrate that through utilizing our algorithm, the throughput can achieve 33% and 20% increase compared with that of traditional transmission scheduling and digital network coding, respectively. Then, we generalize the algorithm so that it can fit for occasions with any number of nodes. We also discuss some technical issues and throughput analysis as well as the bit error rate.

  12. TOPLHA and ALOHA: comparison between Lower Hybrid wave coupling codes

    NASA Astrophysics Data System (ADS)

    Meneghini, Orso; Hillairet, J.; Goniche, M.; Bilato, R.; Voyer, D.; Parker, R.

    2008-11-01

    TOPLHA and ALOHA are wave coupling simulation tools for LH antennas. Both codes are able to account for realistic 3D antenna geometries and use a 1D plasma model. In the framework of a collaboration between MIT and CEA laboratories, the two codes have been extensively compared. In TOPLHA the EM problem is self consistently formulated by means of a set of multiple coupled integral equations having as domain the triangles of the meshed antenna surface. TOPLHA currently uses the FELHS code for modeling the plasma response. ALOHA instead uses a mode matching approach and its own plasma model. Comparisons have been done for several plasma scenarios on different antenna designs: an array of independent waveguides, a multi-junction antenna and a passive/active multi-junction antenna. When simulating the same geometry and plasma conditions the two codes compare remarkably well both for the reflection coefficients and for the launched spectra. The different approach of the two codes to solve the same problem strengthens the confidence in the final results.

  13. Experience with code-switching modulates the use of grammatical gender during sentence processing

    PubMed Central

    Valdés Kroff, Jorge R.; Dussias, Paola E.; Gerfen, Chip; Perrotti, Lauren; Bajo, M. Teresa

    2016-01-01

    Using code-switching as a tool to illustrate how language experience modulates comprehension, the visual world paradigm was employed to examine the extent to which gender-marked Spanish determiners facilitate upcoming target nouns in a group of Spanish-English bilingual code-switchers. The first experiment tested target Spanish nouns embedded in a carrier phrase (Experiment 1b) and included a control Spanish monolingual group (Experiment 1a). The second set of experiments included critical trials in which participants heard code-switches from Spanish determiners into English nouns (e.g., la house) either in a fixed carrier phrase (Experiment 2a) or in variable and complex sentences (Experiment 2b). Across the experiments, bilinguals revealed an asymmetric gender effect in processing, showing facilitation only for feminine target items. These results reflect the asymmetric use of gender in the production of code-switched speech. The extension of the asymmetric effect into Spanish (Experiment 1b) underscores the permeability between language modes in bilingual code-switchers. PMID:28663771

  14. Network perturbation by recurrent regulatory variants in cancer

    PubMed Central

    Cho, Ara; Lee, Insuk; Choi, Jung Kyoon

    2017-01-01

    Cancer driving genes have been identified as recurrently affected by variants that alter protein-coding sequences. However, a majority of cancer variants arise in noncoding regions, and some of them are thought to play a critical role through transcriptional perturbation. Here we identified putative transcriptional driver genes based on combinatorial variant recurrence in cis-regulatory regions. The identified genes showed high connectivity in the cancer type-specific transcription regulatory network, with high outdegree and many downstream genes, highlighting their causative role during tumorigenesis. In the protein interactome, the identified transcriptional drivers were not as highly connected as coding driver genes but appeared to form a network module centered on the coding drivers. The coding and regulatory variants associated via these interactions between the coding and transcriptional drivers showed exclusive and complementary occurrence patterns across tumor samples. Transcriptional cancer drivers may act through an extensive perturbation of the regulatory network and by altering protein network modules through interactions with coding driver genes. PMID:28333928

  15. Sparse coding for flexible, robust 3D facial-expression synthesis.

    PubMed

    Lin, Yuxu; Song, Mingli; Quynh, Dao Thi Phuong; He, Ying; Chen, Chun

    2012-01-01

    Computer animation researchers have been extensively investigating 3D facial-expression synthesis for decades. However, flexible, robust production of realistic 3D facial expressions is still technically challenging. A proposed modeling framework applies sparse coding to synthesize 3D expressive faces, using specified coefficients or expression examples. It also robustly recovers facial expressions from noisy and incomplete data. This approach can synthesize higher-quality expressions in less time than the state-of-the-art techniques.

  16. Nodal network generator for CAVE3

    NASA Technical Reports Server (NTRS)

    Palmieri, J. V.; Rathjen, K. A.

    1982-01-01

    A new extension of CAVE3 code was developed that automates the creation of a finite difference math model in digital form ready for input to the CAVE3 code. The new software, Nodal Network Generator, is broken into two segments. One segment generates the model geometry using a Tektronix Tablet Digitizer and the other generates the actual finite difference model and allows for graphic verification using Tektronix 4014 Graphic Scope. Use of the Nodal Network Generator is described.

  17. Small non-coding RNAs in streptomycetes.

    PubMed

    Heueis, Nona; Vockenhuber, Michael-Paul; Suess, Beatrix

    2014-01-01

    Streptomycetes are Gram-positive, GC-rich, soil dwelling bacteria, occurring ubiquitary throughout nature. They undergo extensive morphological changes from spores to filamentous mycelia and produce a plethora of secondary metabolites. Owing to their complex life cycle, streptomycetes require efficient regulatory machinery for the control of gene expression. Therefore, they possess a large diversity of regulators. Within this review we summarize the current knowledge about the importance of small non-coding RNA for the control of gene expression in these organisms.

  18. Bilayer Protograph Codes for Half-Duplex Relay Channels

    NASA Technical Reports Server (NTRS)

    Divsalar, Dariush; VanNguyen, Thuy; Nosratinia, Aria

    2013-01-01

    Direct to Earth return links are limited by the size and power of lander devices. A standard alternative is provided by a two-hops return link: a proximity link (from lander to orbiter relay) and a deep-space link (from orbiter relay to Earth). Although direct to Earth return links are limited by the size and power of lander devices, using an additional link and a proposed coding for relay channels, one can obtain a more reliable signal. Although significant progress has been made in the relay coding problem, existing codes must be painstakingly optimized to match to a single set of channel conditions, many of them do not offer easy encoding, and most of them do not have structured design. A high-performing LDPC (low-density parity-check) code for the relay channel addresses simultaneously two important issues: a code structure that allows low encoding complexity, and a flexible rate-compatible code that allows matching to various channel conditions. Most of the previous high-performance LDPC codes for the relay channel are tightly optimized for a given channel quality, and are not easily adapted without extensive re-optimization for various channel conditions. This code for the relay channel combines structured design and easy encoding with rate compatibility to allow adaptation to the three links involved in the relay channel, and furthermore offers very good performance. The proposed code is constructed by synthesizing a bilayer structure with a pro to graph. In addition to the contribution to relay encoding, an improved family of protograph codes was produced for the point-to-point AWGN (additive white Gaussian noise) channel whose high-rate members enjoy thresholds that are within 0.07 dB of capacity. These LDPC relay codes address three important issues in an integrative manner: low encoding complexity, modular structure allowing for easy design, and rate compatibility so that the code can be easily matched to a variety of channel conditions without extensive re-optimization. The main problem of half-duplex relay coding can be reduced to the simultaneous design of two codes at two rates and two SNRs (signal-to-noise ratios), such that one is a subset of the other. This problem can be addressed by forceful optimization, but a clever method of addressing this problem is via the bilayer lengthened (BL) LDPC structure. This method uses a bilayer Tanner graph to make the two codes while using a concept of "parity forwarding" with subsequent successive decoding that removes the need to directly address the issue of uneven SNRs among the symbols of a given codeword. This method is attractive in that it addresses some of the main issues in the design of relay codes, but it does not by itself give rise to highly structured codes with simple encoding, nor does it give rate-compatible codes. The main contribution of this work is to construct a class of codes that simultaneously possess a bilayer parity- forwarding mechanism, while also benefiting from the properties of protograph codes having an easy encoding, a modular design, and being a rate-compatible code.

  19. The Limits of Coding with Joint Constraints on Detected and Undetected Error Rates

    NASA Technical Reports Server (NTRS)

    Dolinar, Sam; Andrews, Kenneth; Pollara, Fabrizio; Divsalar, Dariush

    2008-01-01

    We develop a remarkably tight upper bound on the performance of a parameterized family of bounded angle maximum-likelihood (BA-ML) incomplete decoders. The new bound for this class of incomplete decoders is calculated from the code's weight enumerator, and is an extension of Poltyrev-type bounds developed for complete ML decoders. This bound can also be applied to bound the average performance of random code ensembles in terms of an ensemble average weight enumerator. We also formulate conditions defining a parameterized family of optimal incomplete decoders, defined to minimize both the total codeword error probability and the undetected error probability for any fixed capability of the decoder to detect errors. We illustrate the gap between optimal and BA-ML incomplete decoding via simulation of a small code.

  20. Making extreme computations possible with virtual machines

    NASA Astrophysics Data System (ADS)

    Reuter, J.; Chokoufe Nejad, B.; Ohl, T.

    2016-10-01

    State-of-the-art algorithms generate scattering amplitudes for high-energy physics at leading order for high-multiplicity processes as compiled code (in Fortran, C or C++). For complicated processes the size of these libraries can become tremendous (many GiB). We show that amplitudes can be translated to byte-code instructions, which even reduce the size by one order of magnitude. The byte-code is interpreted by a Virtual Machine with runtimes comparable to compiled code and a better scaling with additional legs. We study the properties of this algorithm, as an extension of the Optimizing Matrix Element Generator (O'Mega). The bytecode matrix elements are available as alternative input for the event generator WHIZARD. The bytecode interpreter can be implemented very compactly, which will help with a future implementation on massively parallel GPUs.

  1. Some issues and subtleties in numerical simulation of X-ray FEL's

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fawley, William M.

    Part of the overall design effort for x-ray FEL's such as the LCLS and TESLA projects has involved extensive use of particle simulation codes to predict their output performance and underlying sensitivity to various input parameters (e.g. electron beam emittance). This paper discusses some of the numerical issues that must be addressed by simulation codes in this regime. We first give a brief overview of the standard approximations and simulation methods adopted by time-dependent(i.e. polychromatic) codes such as GINGER, GENESIS, and FAST3D, including the effects of temporal discretization and the resultant limited spectral bandpass,and then discuss the accuracies and inaccuraciesmore » of these codes in predicting incoherent spontaneous emission (i.e. the extremely low gain regime).« less

  2. 26 CFR 157.6161-1 - Extension of time for paying tax.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MISCELLANEOUS EXCISE TAXES (CONTINUED) EXCISE TAX ON STRUCTURED SETTLEMENT FACTORING TRANSACTIONS Procedure and... Factoring Transactions) of the Internal Revenue Code and shown or required to be shown on any return. The...

  3. A Comprehensive Validation Approach Using The RAVEN Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alfonsi, Andrea; Rabiti, Cristian; Cogliati, Joshua J

    2015-06-01

    The RAVEN computer code , developed at the Idaho National Laboratory, is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is a multi-purpose probabilistic and uncertainty quantification platform, capable to communicate with any system code. A natural extension of the RAVEN capabilities is the imple- mentation of an integrated validation methodology, involving several different metrics, that represent an evolution of the methods currently used in the field. The state-of-art vali- dation approaches use neither exploration of the input space through sampling strategies, nor a comprehensive variety of metrics neededmore » to interpret the code responses, with respect experimental data. The RAVEN code allows to address both these lacks. In the following sections, the employed methodology, and its application to the newer developed thermal-hydraulic code RELAP-7, is reported.The validation approach has been applied on an integral effect experiment, representing natu- ral circulation, based on the activities performed by EG&G Idaho. Four different experiment configurations have been considered and nodalized.« less

  4. Glenn-HT: The NASA Glenn Research Center General Multi-Block Navier-Stokes Heat Transfer Code

    NASA Technical Reports Server (NTRS)

    Gaugler, Raymond E.; Lee, Chi-Miag (Technical Monitor)

    2001-01-01

    For the last several years, Glenn-HT, a three-dimensional (3D) Computational Fluid Dynamics (CFD) computer code for the analysis of gas turbine flow and convective heat transfer has been evolving at the NASA Glenn Research Center. The code is unique in the ability to give a highly detailed representation of the flow field very close to solid surfaces in order to get accurate representation of fluid heat transfer and viscous shear stresses. The code has been validated and used extensively for both internal cooling passage flow and for hot gas path flows, including detailed film cooling calculations and complex tip clearance gap flow and heat transfer. In its current form, this code has a multiblock grid capability and has been validated for a number of turbine configurations. The code has been developed and used primarily as a research tool, but it can be useful for detailed design analysis. In this paper, the code is described and examples of its validation and use for complex flow calculations are presented, emphasizing the applicability to turbomachinery for space launch vehicle propulsion systems.

  5. Glenn-HT: The NASA Glenn Research Center General Multi-Block Navier-Stokes Heat Transfer Code

    NASA Technical Reports Server (NTRS)

    Gaugfer, Raymond E.

    2002-01-01

    For the last several years, Glenn-HT, a three-dimensional (3D) Computational Fluid Dynamics (CFD) computer code for the analysis of gas turbine flow and convective heat transfer has been evolving at the NASA Glenn Research Center. The code is unique in the ability to give a highly detailed representation of the flow field very close to solid surfaces in order to get accurate representation of fluid heat transfer and viscous shear stresses. The code has been validated and used extensively for both internal cooling passage flow and for hot gas path flows, including detailed film cooling calculations and complex tip clearance gap flow and heat transfer. In its current form, this code has a multiblock grid capability and has been validated for a number of turbine configurations. The code has been developed and used primarily as a research tool, but it can be useful for detailed design analysis. In this presentation, the code is described and examples of its validation and use for complex flow calculations are presented, emphasizing the applicability to turbomachinery.

  6. Glenn-HT: The NASA Glenn Research Center General Multi-Block Navier Stokes Heat Transfer Code

    NASA Technical Reports Server (NTRS)

    Gaugler, Raymond E.

    2002-01-01

    For the last several years, Glenn-HT, a three-dimensional (3D) Computational Fluid Dynamics (CFD) computer code for the analysis of gas turbine flow and convective heat transfer has been evolving at the NASA Glenn Research Center. The code is unique in the ability to give a highly detailed representation of the flow field very close to solid surfaces in order to get accurate representation of fluid beat transfer and viscous shear stresses. The code has been validated and used extensively for both internal cooling passage flow and for hot gas path flows, including detailed film cooling calculations and complex tip clearance gap flow and heat transfer. In its current form, this code has a multiblock grid capability and has been validated for a number of turbine configurations. The code has been developed and used primarily as a research tool, but it can be useful for detailed design analysis. In this presentation, the code is described and examples of its validation and use for complex flow calculations are presented, emphasizing the applicability to turbomachinery.

  7. Statistical Analysis of the AIAA Drag Prediction Workshop CFD Solutions

    NASA Technical Reports Server (NTRS)

    Morrison, Joseph H.; Hemsch, Michael J.

    2007-01-01

    The first AIAA Drag Prediction Workshop (DPW), held in June 2001, evaluated the results from an extensive N-version test of a collection of Reynolds-Averaged Navier-Stokes CFD codes. The code-to-code scatter was more than an order of magnitude larger than desired for design and experimental validation of cruise conditions for a subsonic transport configuration. The second AIAA Drag Prediction Workshop, held in June 2003, emphasized the determination of installed pylon-nacelle drag increments and grid refinement studies. The code-to-code scatter was significantly reduced compared to the first DPW, but still larger than desired. However, grid refinement studies showed no significant improvement in code-to-code scatter with increasing grid refinement. The third AIAA Drag Prediction Workshop, held in June 2006, focused on the determination of installed side-of-body fairing drag increments and grid refinement studies for clean attached flow on wing alone configurations and for separated flow on the DLR-F6 subsonic transport model. This report compares the transonic cruise prediction results of the second and third workshops using statistical analysis.

  8. An extension of the coevolution theory of the origin of the genetic code

    PubMed Central

    Di Giulio, Massimo

    2008-01-01

    Background The coevolution theory of the origin of the genetic code suggests that the genetic code is an imprint of the biosynthetic relationships between amino acids. However, this theory does not seem to attribute a role to the biosynthetic relationships between the earliest amino acids that evolved along the pathways of energetic metabolism. As a result, the coevolution theory is unable to clearly define the very earliest phases of genetic code origin. In order to remove this difficulty, I here suggest an extension of the coevolution theory that attributes a crucial role to the first amino acids that evolved along these biosynthetic pathways and to their biosynthetic relationships, even when defined by the non-amino acid molecules that are their precursors. Results It is re-observed that the first amino acids to evolve along these biosynthetic pathways are predominantly those codified by codons of the type GNN, and this observation is found to be statistically significant. Furthermore, the close biosynthetic relationships between the sibling amino acids Ala-Ser, Ser-Gly, Asp-Glu, and Ala-Val are not random in the genetic code table and reinforce the hypothesis that the biosynthetic relationships between these six amino acids played a crucial role in defining the very earliest phases of genetic code origin. Conclusion All this leads to the hypothesis that there existed a code, GNS, reflecting the biosynthetic relationships between these six amino acids which, as it defines the very earliest phases of genetic code origin, removes the main difficulty of the coevolution theory. Furthermore, it is here discussed how this code might have naturally led to the code codifying only for the domains of the codons of precursor amino acids, as predicted by the coevolution theory. Finally, the hypothesis here suggested also removes other problems of the coevolution theory, such as the existence for certain pairs of amino acids with an unclear biosynthetic relationship between the precursor and product amino acids and the collocation of Ala between the amino acids Val and Leu belonging to the pyruvate biosynthetic family, which the coevolution theory considered as belonging to different biosyntheses. Reviewers This article was reviewed by Rob Knight, Paul Higgs (nominated by Laura Landweber), and Eugene Koonin. PMID:18775066

  9. CESAR: A Code for Nuclear Fuel and Waste Characterisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vidal, J.M.; Grouiller, J.P.; Launay, A.

    2006-07-01

    CESAR (Simplified Evolution Code Applied to Reprocessing) is a depletion code developed through a joint program between CEA and COGEMA. In the late 1980's, the first use of this code dealt with nuclear measurement at the Laboratories of the La Hague reprocessing plant. The use of CESAR was then extended to characterizations of all entrance materials and for characterisation, via tracer, of all produced waste. The code can distinguish more than 100 heavy nuclides, 200 fission products and 100 activation products, and it can characterise both the fuel and the structural material of the fuel. CESAR can also make depletionmore » calculations from 3 months to 1 million years of cooling time. Between 2003-2005, the 5. version of the code was developed. The modifications were related to the harmonisation of the code's nuclear data with the JEF2.2 nuclear data file. This paper describes the code and explains the extensive use of this code at the La Hague reprocessing plant and also for prospective studies. The second part focuses on the modifications of the latest version, and describes the application field and the qualification of the code. Many companies and the IAEA use CESAR today. CESAR offers a Graphical User Interface, which is very user-friendly. (authors)« less

  10. A generalized one-dimensional computer code for turbomachinery cooling passage flow calculations

    NASA Technical Reports Server (NTRS)

    Kumar, Ganesh N.; Roelke, Richard J.; Meitner, Peter L.

    1989-01-01

    A generalized one-dimensional computer code for analyzing the flow and heat transfer in the turbomachinery cooling passages was developed. This code is capable of handling rotating cooling passages with turbulators, 180 degree turns, pin fins, finned passages, by-pass flows, tip cap impingement flows, and flow branching. The code is an extension of a one-dimensional code developed by P. Meitner. In the subject code, correlations for both heat transfer coefficient and pressure loss computations were developed to model each of the above mentioned type of coolant passages. The code has the capability of independently computing the friction factor and heat transfer coefficient on each side of a rectangular passage. Either the mass flow at the inlet to the channel or the exit plane pressure can be specified. For a specified inlet total temperature, inlet total pressure, and exit static pressure, the code computers the flow rates through the main branch and the subbranches, flow through tip cap for impingement cooling, in addition to computing the coolant pressure, temperature, and heat transfer coefficient distribution in each coolant flow branch. Predictions from the subject code for both nonrotating and rotating passages agree well with experimental data. The code was used to analyze the cooling passage of a research cooled radial rotor.

  11. Extending the Coyote emulator to dark energy models with standard w {sub 0}- w {sub a} parametrization of the equation of state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casarini, L.; Bonometto, S.A.; Tessarotto, E.

    2016-08-01

    We discuss an extension of the Coyote emulator to predict non-linear matter power spectra of dark energy (DE) models with a scale factor dependent equation of state of the form w = w {sub 0}+(1- a ) w {sub a} . The extension is based on the mapping rule between non-linear spectra of DE models with constant equation of state and those with time varying one originally introduced in ref. [40]. Using a series of N-body simulations we show that the spectral equivalence is accurate to sub-percent level across the same range of modes and redshift covered by the Coyotemore » suite. Thus, the extended emulator provides a very efficient and accurate tool to predict non-linear power spectra for DE models with w {sub 0}- w {sub a} parametrization. According to the same criteria we have developed a numerical code that we have implemented in a dedicated module for the CAMB code, that can be used in combination with the Coyote Emulator in likelihood analyses of non-linear matter power spectrum measurements. All codes can be found at https://github.com/luciano-casarini/pkequal.« less

  12. Infrastructure for Rapid Development of Java GUI Programs

    NASA Technical Reports Server (NTRS)

    Jones, Jeremy; Hostetter, Carl F.; Wheeler, Philip

    2006-01-01

    The Java Application Shell (JAS) is a software framework that accelerates the development of Java graphical-user-interface (GUI) application programs by enabling the reuse of common, proven GUI elements, as distinguished from writing custom code for GUI elements. JAS is a software infrastructure upon which Java interactive application programs and graphical user interfaces (GUIs) for those programs can be built as sets of plug-ins. JAS provides an application- programming interface that is extensible by application-specific plugins that describe and encapsulate both specifications of a GUI and application-specific functionality tied to the specified GUI elements. The desired GUI elements are specified in Extensible Markup Language (XML) descriptions instead of in compiled code. JAS reads and interprets these descriptions, then creates and configures a corresponding GUI from a standard set of generic, reusable GUI elements. These elements are then attached (again, according to the XML descriptions) to application-specific compiled code and scripts. An application program constructed by use of JAS as its core can be extended by writing new plug-ins and replacing existing plug-ins. Thus, JAS solves many problems that Java programmers generally solve anew for each project, thereby reducing development and testing time.

  13. Early MIMD experience on the CRAY X-MP

    NASA Astrophysics Data System (ADS)

    Rhoades, Clifford E.; Stevens, K. G.

    1985-07-01

    This paper describes some early experience with converting four physics simulation programs to the CRAY X-MP, a current Multiple Instruction, Multiple Data (MIMD) computer consisting of two processors each with an architecture similar to that of the CRAY-1. As a multi-processor, the CRAY X-MP together with the high speed Solid-state Storage Device (SSD) in an ideal machine upon which to study MIMD algorithms for solving the equations of mathematical physics because it is fast enough to run real problems. The computer programs used in this study are all FORTRAN versions of original production codes. They range in sophistication from a one-dimensional numerical simulation of collisionless plasma to a two-dimensional hydrodynamics code with heat flow to a couple of three-dimensional fluid dynamics codes with varying degrees of viscous modeling. Early research with a dual processor configuration has shown speed-ups ranging from 1.55 to 1.98. It has been observed that a few simple extensions to FORTRAN allow a typical programmer to achieve a remarkable level of efficiency. These extensions involve the concept of memory local to a concurrent subprogram and memory common to all concurrent subprograms.

  14. Multiframe video coding for improved performance over wireless channels.

    PubMed

    Budagavi, M; Gibson, J D

    2001-01-01

    We propose and evaluate a multi-frame extension to block motion compensation (BMC) coding of videoconferencing-type video signals for wireless channels. The multi-frame BMC (MF-BMC) coder makes use of the redundancy that exists across multiple frames in typical videoconferencing sequences to achieve additional compression over that obtained by using the single frame BMC (SF-BMC) approach, such as in the base-level H.263 codec. The MF-BMC approach also has an inherent ability of overcoming some transmission errors and is thus more robust when compared to the SF-BMC approach. We model the error propagation process in MF-BMC coding as a multiple Markov chain and use Markov chain analysis to infer that the use of multiple frames in motion compensation increases robustness. The Markov chain analysis is also used to devise a simple scheme which randomizes the selection of the frame (amongst the multiple previous frames) used in BMC to achieve additional robustness. The MF-BMC coders proposed are a multi-frame extension of the base level H.263 coder and are found to be more robust than the base level H.263 coder when subjected to simulated errors commonly encountered on wireless channels.

  15. Programming with BIG data in R: Scaling analytics from one to thousands of nodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, Drew; Chen, Wei -Chen; Matheson, Michael A.

    Here, we present a tutorial overview showing how one can achieve scalable performance with R. We do so by utilizing several package extensions, including those from the pbdR project. These packages consist of high performance, high-level interfaces to and extensions of MPI, PBLAS, ScaLAPACK, I/O libraries, profiling libraries, and more. While these libraries shine brightest on large distributed platforms, they also work rather well on small clusters and often, surprisingly, even on a laptop with only two cores. Our tutorial begins with recommendations on how to get more performance out of your R code before considering parallel implementations. Because Rmore » is a high-level language, a function can have a deep hierarchy of operations. For big data, this can easily lead to inefficiency. Profiling is an important tool to understand the performance of an R code for both serial and parallel improvements.« less

  16. Gene encoding the human. beta. -hexosaminidase. beta. chain: Extensive homology of intron placement in the. alpha. - and. beta. -chain genes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Proia, R.L.

    1988-03-01

    Lysosomal {beta}-hexosaminidase is composed of two structurally similar chains, {alpha} and {beta}, that are the products of different genes. Mutations in either gene causing {beta}-hexosaminidase deficiency result in the lysosomal storage disease GM2-gangliosidosis. To enable the investigation of the molecular lesions in this disorder and to study the evolutionary relationship between the {alpha} and {beta} chains, the {beta}-chain gene was isolated, and its organization was characterized. The {beta}-chain coding region is divided into 14 exons distributed over {approx}40 kilobases of DNA. Comparison with the {alpha}-chain gene revealed that 12 of the 13 introns interrupt the coding regions at homologous positions.more » This extensive sharing of intron placement demonstrates that the {alpha} and {beta} chains evolved by way of the duplication of a common ancestor.« less

  17. Extension of the SIESTA MHD equilibrium code to free-plasma-boundary problems

    DOE PAGES

    Peraza-Rodriguez, Hugo; Reynolds-Barredo, J. M.; Sanchez, Raul; ...

    2017-08-28

    Here, SIESTA is a recently developed MHD equilibrium code designed to perform fast and accurate calculations of ideal MHD equilibria for three-dimensional magnetic configurations. Since SIESTA does not assume closed magnetic surfaces, the solution can exhibit magnetic islands and stochastic regions. In its original implementation SIESTA addressed only fixed-boundary problems. That is, the shape of the plasma edge, assumed to be a magnetic surface, was kept fixed as the solution iteratively converges to equilibrium. This condition somewhat restricts the possible applications of SIESTA. In this paper we discuss an extension that will enable SIESTA to address free-plasma-boundary problems, opening upmore » the possibility of investigating problems in which the plasma boundary is perturbed either externally or internally. As an illustration, SIESTA is applied to a configuration of the W7-X stellarator.« less

  18. Extension of the SIESTA MHD equilibrium code to free-plasma-boundary problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peraza-Rodriguez, Hugo; Reynolds-Barredo, J. M.; Sanchez, Raul

    Here, SIESTA is a recently developed MHD equilibrium code designed to perform fast and accurate calculations of ideal MHD equilibria for three-dimensional magnetic configurations. Since SIESTA does not assume closed magnetic surfaces, the solution can exhibit magnetic islands and stochastic regions. In its original implementation SIESTA addressed only fixed-boundary problems. That is, the shape of the plasma edge, assumed to be a magnetic surface, was kept fixed as the solution iteratively converges to equilibrium. This condition somewhat restricts the possible applications of SIESTA. In this paper we discuss an extension that will enable SIESTA to address free-plasma-boundary problems, opening upmore » the possibility of investigating problems in which the plasma boundary is perturbed either externally or internally. As an illustration, SIESTA is applied to a configuration of the W7-X stellarator.« less

  19. Programming with BIG data in R: Scaling analytics from one to thousands of nodes

    DOE PAGES

    Schmidt, Drew; Chen, Wei -Chen; Matheson, Michael A.; ...

    2016-11-09

    Here, we present a tutorial overview showing how one can achieve scalable performance with R. We do so by utilizing several package extensions, including those from the pbdR project. These packages consist of high performance, high-level interfaces to and extensions of MPI, PBLAS, ScaLAPACK, I/O libraries, profiling libraries, and more. While these libraries shine brightest on large distributed platforms, they also work rather well on small clusters and often, surprisingly, even on a laptop with only two cores. Our tutorial begins with recommendations on how to get more performance out of your R code before considering parallel implementations. Because Rmore » is a high-level language, a function can have a deep hierarchy of operations. For big data, this can easily lead to inefficiency. Profiling is an important tool to understand the performance of an R code for both serial and parallel improvements.« less

  20. F-16XL-2 Supersonic Laminar Flow Control Flight Test Experiment

    NASA Technical Reports Server (NTRS)

    Anders, Scott G.; Fischer, Michael C.

    1999-01-01

    The F-16XL-2 Supersonic Laminar Flow Control Flight Test Experiment was part of the NASA High-Speed Research Program. The goal of the experiment was to demonstrate extensive laminar flow, to validate computational fluid dynamics (CFD) codes and design methodology, and to establish laminar flow control design criteria. Topics include the flight test hardware and design, airplane modification, the pressure and suction distributions achieved, the laminar flow achieved, and the data analysis and code correlation.

  1. New developments of the CARTE thermochemical code: A two-phase equation of state for nanocarbons

    NASA Astrophysics Data System (ADS)

    Dubois, Vincent; Pineau, Nicolas

    2016-01-01

    We developed a new equation of state (EOS) for nanocarbons in the thermodynamic range of high explosives detonation products (up to 50 GPa and 4000 K). This EOS was fitted to an extensive database of thermodynamic properties computed by molecular dynamics simulations of nanodiamonds and nano-onions with the LCBOPII potential. We reproduced the detonation properties of a variety of high explosives with the CARTE thermochemical code, including carbon-poor and carbon-rich explosives, with excellent accuracy.

  2. An interactive HTML ocean nowcast GUI based on Perl and JavaScript

    NASA Astrophysics Data System (ADS)

    Sakalaukus, Peter J.; Fox, Daniel N.; Louise Perkins, A.; Smedstad, Lucy F.

    1999-02-01

    We describe the use of Hyper Text Markup Language (HTML), JavaScript code, and Perl I/O to create and validate forms in an Internet-based graphical user interface (GUI) for the Naval Research Laboratory (NRL) Ocean models and Assimilation Demonstration System (NOMADS). The resulting nowcast system can be operated from any compatible browser across the Internet, for although the GUI was prepared in a Netscape browser, it used no Netscape extensions. Code available at: http://www.iamg.org/CGEditor/index.htm

  3. Additional application of the NASCAP code. Volume 1: NASCAP extension

    NASA Technical Reports Server (NTRS)

    Katz, I.; Cassidy, J. J.; Mandell, M. J.; Parks, D. E.; Schnuelle, G. W.; Stannard, P. R.; Steen, P. G.

    1981-01-01

    The NASCAP computer program comprehensively analyzes problems of spacecraft charging. Using a fully three dimensional approach, it can accurately predict spacecraft potentials under a variety of conditions. Several changes were made to NASCAP, and a new code, NASCAP/LEO, was developed. In addition, detailed studies of several spacecraft-environmental interactions and of the SCATHA spacecraft were performed. The NASCAP/LEO program handles situations of relatively short Debye length encountered by large space structures or by any satellite in low earth orbit (LEO).

  4. Time-Reversal Based Range Extension Technique for Ultra-Wideband (UWB) Sensors and Applications in Tactical Communications and Networking

    DTIC Science & Technology

    2007-07-16

    issue to find a proper acquisition strategy and to optimize the algorithm. So far a two-stage acquisition algorithm based on the optical orthogonal...vol.5, May 11-15, 2003, pp. 3530-3534. [23] M. Weisenhorn and W. Hirt, "Robust noncoherent receiver exploiting UWB channel properties," in Proc. IEEE...PRF) and data rate, are programmable. I Depending on the propagation environments, either the Barker code or the optical orthogonal codes (OOC) [53

  5. Recent Improvements in the FDNS CFD Code and its Associated Process

    NASA Technical Reports Server (NTRS)

    West, Jeff S.; Dorney, Suzanne M.; Turner, Jim (Technical Monitor)

    2002-01-01

    This viewgraph presentation gives an overview on recent improvements in the Finite Difference Navier Stokes (FDNS) computational fluid dynamics (CFD) code and its associated process. The development of a utility, PreViewer, has essentially eliminated the creeping of simple human error into the FDNS Solution process. Extension of PreViewer to encapsulate the Domain Decompression process has made practical the routine use of parallel processing. The combination of CVS source control and ATS consistency validation significantly increases the efficiency of the CFD process.

  6. Digital visual communications using a Perceptual Components Architecture

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    1991-01-01

    The next era of space exploration will generate extraordinary volumes of image data, and management of this image data is beyond current technical capabilities. We propose a strategy for coding visual information that exploits the known properties of early human vision. This Perceptual Components Architecture codes images and image sequences in terms of discrete samples from limited bands of color, spatial frequency, orientation, and temporal frequency. This spatiotemporal pyramid offers efficiency (low bit rate), variable resolution, device independence, error-tolerance, and extensibility.

  7. DataRocket: Interactive Visualisation of Data Structures

    NASA Astrophysics Data System (ADS)

    Parkes, Steve; Ramsay, Craig

    2010-08-01

    CodeRocket is a software engineering tool that provides cognitive support to the software engineer for reasoning about a method or procedure and for documenting the resulting code [1]. DataRocket is a software engineering tool designed to support visualisation and reasoning about program data structures. DataRocket is part of the CodeRocket family of software tools developed by Rapid Quality Systems [2] a spin-out company from the Space Technology Centre at the University of Dundee. CodeRocket and DataRocket integrate seamlessly with existing architectural design and coding tools and provide extensive documentation with little or no effort on behalf of the software engineer. Comprehensive, abstract, detailed design documentation is available early on in a project so that it can be used for design reviews with project managers and non expert stakeholders. Code and documentation remain fully synchronised even when changes are implemented in the code without reference to the existing documentation. At the end of a project the press of a button suffices to produce the detailed design document. Existing legacy code can be easily imported into CodeRocket and DataRocket to reverse engineer detailed design documentation making legacy code more manageable and adding substantially to its value. This paper introduces CodeRocket. It then explains the rationale for DataRocket and describes the key features of this new tool. Finally the major benefits of DataRocket for different stakeholders are considered.

  8. A glacier runoff extension to the Precipitation Runoff Modeling System

    USGS Publications Warehouse

    Van Beusekom, Ashley E.; Viger, Roland

    2016-01-01

    A module to simulate glacier runoff, PRMSglacier, was added to PRMS (Precipitation Runoff Modeling System), a distributed-parameter, physical-process hydrological simulation code. The extension does not require extensive on-glacier measurements or computational expense but still relies on physical principles over empirical relations as much as is feasible while maintaining model usability. PRMSglacier is validated on two basins in Alaska, Wolverine, and Gulkana Glacier basin, which have been studied since 1966 and have a substantial amount of data with which to test model performance over a long period of time covering a wide range of climatic and hydrologic conditions. When error in field measurements is considered, the Nash-Sutcliffe efficiencies of streamflow are 0.87 and 0.86, the absolute bias fractions of the winter mass balance simulations are 0.10 and 0.08, and the absolute bias fractions of the summer mass balances are 0.01 and 0.03, all computed over 42 years for the Wolverine and Gulkana Glacier basins, respectively. Without taking into account measurement error, the values are still within the range achieved by the more computationally expensive codes tested over shorter time periods.

  9. fast_protein_cluster: parallel and optimized clustering of large-scale protein modeling data.

    PubMed

    Hung, Ling-Hong; Samudrala, Ram

    2014-06-15

    fast_protein_cluster is a fast, parallel and memory efficient package used to cluster 60 000 sets of protein models (with up to 550 000 models per set) generated by the Nutritious Rice for the World project. fast_protein_cluster is an optimized and extensible toolkit that supports Root Mean Square Deviation after optimal superposition (RMSD) and Template Modeling score (TM-score) as metrics. RMSD calculations using a laptop CPU are 60× faster than qcprot and 3× faster than current graphics processing unit (GPU) implementations. New GPU code further increases the speed of RMSD and TM-score calculations. fast_protein_cluster provides novel k-means and hierarchical clustering methods that are up to 250× and 2000× faster, respectively, than Clusco, and identify significantly more accurate models than Spicker and Clusco. fast_protein_cluster is written in C++ using OpenMP for multi-threading support. Custom streaming Single Instruction Multiple Data (SIMD) extensions and advanced vector extension intrinsics code accelerate CPU calculations, and OpenCL kernels support AMD and Nvidia GPUs. fast_protein_cluster is available under the M.I.T. license. (http://software.compbio.washington.edu/fast_protein_cluster) © The Author 2014. Published by Oxford University Press.

  10. Verification and Validation Strategy for LWRS Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carl M. Stoots; Richard R. Schultz; Hans D. Gougar

    2012-09-01

    One intension of the Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is to create advanced computational tools for safety assessment that enable more accurate representation of a nuclear power plant safety margin. These tools are to be used to study the unique issues posed by lifetime extension and relicensing of the existing operating fleet of nuclear power plants well beyond their first license extension period. The extent to which new computational models / codes such as RELAP-7 can be used for reactor licensing / relicensing activities depends mainly upon the thoroughness with which they have been verifiedmore » and validated (V&V). This document outlines the LWRS program strategy by which RELAP-7 code V&V planning is to be accomplished. From the perspective of developing and applying thermal-hydraulic and reactivity-specific models to reactor systems, the US Nuclear Regulatory Commission (NRC) Regulatory Guide 1.203 gives key guidance to numeric model developers and those tasked with the validation of numeric models. By creating Regulatory Guide 1.203 the NRC defined a framework for development, assessment, and approval of transient and accident analysis methods. As a result, this methodology is very relevant and is recommended as the path forward for RELAP-7 V&V. However, the unique issues posed by lifetime extension will require considerations in addition to those addressed in Regulatory Guide 1.203. Some of these include prioritization of which plants / designs should be studied first, coupling modern supporting experiments to the stringent needs of new high fidelity models / codes, and scaling of aging effects.« less

  11. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    PubMed

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  12. A plug-in to Eclipse for VHDL source codes: functionalities

    NASA Astrophysics Data System (ADS)

    Niton, B.; Poźniak, K. T.; Romaniuk, R. S.

    The paper presents an original application, written by authors, which supports writing and edition of source codes in VHDL language. It is a step towards fully automatic, augmented code writing for photonic and electronic systems, also systems based on FPGA and/or DSP processors. An implementation is described, based on VEditor. VEditor is a free license program. Thus, the work presented in this paper supplements and extends this free license. The introduction characterizes shortly available tools on the market which serve for aiding the design processes of electronic systems in VHDL. Particular attention was put on plug-ins to the Eclipse environment and Emacs program. There are presented detailed properties of the written plug-in such as: programming extension conception, and the results of the activities of formatter, re-factorizer, code hider, and other new additions to the VEditor program.

  13. Solving free-plasma-boundary problems with the SIESTA MHD code

    NASA Astrophysics Data System (ADS)

    Sanchez, R.; Peraza-Rodriguez, H.; Reynolds-Barredo, J. M.; Tribaldos, V.; Geiger, J.; Hirshman, S. P.; Cianciosa, M.

    2017-10-01

    SIESTA is a recently developed MHD equilibrium code designed to perform fast and accurate calculations of ideal MHD equilibria for 3D magnetic configurations. It is an iterative code that uses the solution obtained by the VMEC code to provide a background coordinate system and an initial guess of the solution. The final solution that SIESTA finds can exhibit magnetic islands and stochastic regions. In its original implementation, SIESTA addressed only fixed-boundary problems. This fixed boundary condition somewhat restricts its possible applications. In this contribution we describe a recent extension of SIESTA that enables it to address free-plasma-boundary situations, opening up the possibility of investigating problems with SIESTA in which the plasma boundary is perturbed either externally or internally. As an illustration, the extended version of SIESTA is applied to a configuration of the W7-X stellarator.

  14. Review and Implementation of the Emerging CCSDS Recommended Standard for Multispectral and Hyperspectral Lossless Image Coding

    NASA Technical Reports Server (NTRS)

    Sanchez, Jose Enrique; Auge, Estanislau; Santalo, Josep; Blanes, Ian; Serra-Sagrista, Joan; Kiely, Aaron

    2011-01-01

    A new standard for image coding is being developed by the MHDC working group of the CCSDS, targeting onboard compression of multi- and hyper-spectral imagery captured by aircraft and satellites. The proposed standard is based on the "Fast Lossless" adaptive linear predictive compressor, and is adapted to better overcome issues of onboard scenarios. In this paper, we present a review of the state of the art in this field, and provide an experimental comparison of the coding performance of the emerging standard in relation to other state-of-the-art coding techniques. Our own independent implementation of the MHDC Recommended Standard, as well as of some of the other techniques, has been used to provide extensive results over the vast corpus of test images from the CCSDS-MHDC.

  15. Experiences with Cray multi-tasking

    NASA Technical Reports Server (NTRS)

    Miya, E. N.

    1985-01-01

    The issues involved in modifying an existing code for multitasking is explored. They include Cray extensions to FORTRAN, an examination of the application code under study, designing workable modifications, specific code modifications to the VAX and Cray versions, performance, and efficiency results. The finished product is a faster, fully synchronous, parallel version of the original program. A production program is partitioned by hand to run on two CPUs. Loop splitting multitasks three key subroutines. Simply dividing subroutine data and control structure down the middle of a subroutine is not safe. Simple division produces results that are inconsistent with uniprocessor runs. The safest way to partition the code is to transfer one block of loops at a time and check the results of each on a test case. Other issues include debugging and performance. Task startup and maintenance (e.g., synchronization) are potentially expensive.

  16. A nonlocal electron conduction model for multidimensional radiation hydrodynamics codes

    NASA Astrophysics Data System (ADS)

    Schurtz, G. P.; Nicolaï, Ph. D.; Busquet, M.

    2000-10-01

    Numerical simulation of laser driven Inertial Confinement Fusion (ICF) related experiments require the use of large multidimensional hydro codes. Though these codes include detailed physics for numerous phenomena, they deal poorly with electron conduction, which is the leading energy transport mechanism of these systems. Electron heat flow is known, since the work of Luciani, Mora, and Virmont (LMV) [Phys. Rev. Lett. 51, 1664 (1983)], to be a nonlocal process, which the local Spitzer-Harm theory, even flux limited, is unable to account for. The present work aims at extending the original formula of LMV to two or three dimensions of space. This multidimensional extension leads to an equivalent transport equation suitable for easy implementation in a two-dimensional radiation-hydrodynamic code. Simulations are presented and compared to Fokker-Planck simulations in one and two dimensions of space.

  17. Learning Short Binary Codes for Large-scale Image Retrieval.

    PubMed

    Liu, Li; Yu, Mengyang; Shao, Ling

    2017-03-01

    Large-scale visual information retrieval has become an active research area in this big data era. Recently, hashing/binary coding algorithms prove to be effective for scalable retrieval applications. Most existing hashing methods require relatively long binary codes (i.e., over hundreds of bits, sometimes even thousands of bits) to achieve reasonable retrieval accuracies. However, for some realistic and unique applications, such as on wearable or mobile devices, only short binary codes can be used for efficient image retrieval due to the limitation of computational resources or bandwidth on these devices. In this paper, we propose a novel unsupervised hashing approach called min-cost ranking (MCR) specifically for learning powerful short binary codes (i.e., usually the code length shorter than 100 b) for scalable image retrieval tasks. By exploring the discriminative ability of each dimension of data, MCR can generate one bit binary code for each dimension and simultaneously rank the discriminative separability of each bit according to the proposed cost function. Only top-ranked bits with minimum cost-values are then selected and grouped together to compose the final salient binary codes. Extensive experimental results on large-scale retrieval demonstrate that MCR can achieve comparative performance as the state-of-the-art hashing algorithms but with significantly shorter codes, leading to much faster large-scale retrieval.

  18. Maclisp extensions

    NASA Technical Reports Server (NTRS)

    Bawden, A.; Burke, G. S.; Hoffman, C. W.

    1981-01-01

    A common subset of selected facilities available in Maclisp and its derivatives (PDP-10 and Multics Maclisp, Lisp Machine Lisp (Zetalisp), and NIL) is decribed. The object is to add in writing code which can run compatibly in more than one of these environments.

  19. 77 FR 30972 - Certain Polybrominated Diphenylethers; Significant New Use Rule and Test Rule; Extension of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-24

    ... technical information contact: Catherine Roman, Chemical Control Division, Office of Pollution Prevention... Safety and Pollution Prevention. [FR Doc. 2012-12625 Filed 5-23-12; 8:45 am] BILLING CODE 6560-50-P ...

  20. Promoting the Adoption of Radon-Resistant New Construction Codes: Kane County, Illinois

    EPA Pesticide Factsheets

    As a member of the Manhattan City Council and the Kansas State Radon Extension Program, Bruce Snead was in an excellent position to champion the adoption of radon-resistant new construction (RRNC) in Manhattan, Kansas.

Top