Biomass cogeneration: A business assessment
NASA Astrophysics Data System (ADS)
Skelton, J. C.
1981-11-01
The biomass cogeneration was reviewed. The business assessment is based in part on discussions with key officials from firms that have adopted biomass cogeneration systems and from organizations such as utilities, state and federal agencies, and banks directly involved in a biomass cogeneration project. The guide is organized into five chapters: biomass cogeneration systems, biomass cogeneration business considerations, biomass cogeneration economics, biomass cogeneration project planning, and case studies.
Advanced Cogeneration Technology Economic Optimization Study (ACTEOS)
NASA Technical Reports Server (NTRS)
Nanda, P.; Ansu, Y.; Manuel, E. H., Jr.; Price, W. G., Jr.
1980-01-01
The advanced cogeneration technology economic optimization study (ACTEOS) was undertaken to extend the results of the cogeneration technology alternatives study (CTAS). Cost comparisons were made between designs involving advanced cogeneration technologies and designs involving either conventional cogeneration technologies or not involving cogeneration. For the specific equipment cost and fuel price assumptions made, it was found that: (1) coal based cogeneration systems offered appreciable cost savings over the no cogeneration case, while systems using coal derived liquids offered no costs savings; and (2) the advanced cogeneration systems provided somewhat larger cost savings than the conventional systems. Among the issues considered in the study included: (1) temporal variations in steam and electric demands; (2) requirements for reliability/standby capacity; (3) availability of discrete equipment sizes; (4) regional variations in fuel and electricity prices; (5) off design system performance; and (6) separate demand and energy charges for purchased electricity.
Cogeneration: A Campus Option? A Cogeneration Manual for Colleges and Universities.
ERIC Educational Resources Information Center
Goble, Robert Lloyd; Goble, Wendy Coleman
Guidelines for colleges who may want to implement cogeneration on their campuses are presented. Cogeneration has been defined as "the simultaneous production of electric power and other forms of useful energy--such as heat or process steam--from the same facility." The history of cogeneration, current and future technologies, and…
Small-scale biomass fueled cogeneration systems - A guidebook for general audiences
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiltsee, G.
1993-12-01
What is cogeneration and how does it reduce costs? Cogeneration is the production of power -- and useful heat -- from the same fuel. In a typical biomass-fueled cogeneration plant, a steam turbine drives a generator, producing electricity. The plant uses steam from the turbine for heating, drying, or other uses. The benefits of cogeneration can mostly easily be seen through actual samples. For example, cogeneration fits well with the operation of sawmills. Sawmills can produce more steam from their waste wood than they need for drying lumber. Wood waste is a disposal problem unless the sawmill converts it tomore » energy. The case studies in Section 8 illustrate some pluses and minuses of cogeneration. The electricity from the cogeneration plant can do more than meet the in-house requirements of the mill or manufacturing plant. PURPA -- the Public Utilities Regulatory Policies Act of 1978 -- allows a cogenerator to sell power to a utility and make money on the excess power it produces. It requires the utility to buy the power at a fair price -- the utility`s {open_quotes}avoided cost.{close_quotes} This can help make operation of a cogeneration plant practical.« less
Advanced cogeneration research study: Executive summary
NASA Technical Reports Server (NTRS)
Bluhm, S. A.; Moore, N.; Rosenberg, L.; Slonski, M.
1983-01-01
This study provides a broad based overview of selected areas relevant to the development of a comprehensive Southern California Edison (SCE) advanced cogeneration project. The areas studied are: (1) Cogeneration potential in the SCE service territory; (2) Advanced cogeneration technologies; and (3) Existing cogeneration computer models. An estimated 3700 MW sub E could potentially be generated from existing industries in the Southern California Edison service territory using cogeneration technology. Of this total, current technology could provide 2600 MW sub E and advanced technology could provide 1100 MW sub E. The manufacturing sector (SIC Codes 20-39) was found to have the highest average potential for current cogeneration technology. The mining sector (SIC Codes 10-14) was found to have the highest potential for advanced technology.
Cogeneration computer model assessment: Advanced cogeneration research study
NASA Technical Reports Server (NTRS)
Rosenberg, L.
1983-01-01
Cogeneration computer simulation models to recommend the most desirable models or their components for use by the Southern California Edison Company (SCE) in evaluating potential cogeneration projects was assessed. Existing cogeneration modeling capabilities are described, preferred models are identified, and an approach to the development of a code which will best satisfy SCE requirements is recommended. Five models (CELCAP, COGEN 2, CPA, DEUS, and OASIS) are recommended for further consideration.
Initial Feasibility Report on Decentralized Small Cogeneration for Navy Shore Bases.
1984-02-01
PURPA ), they generally had stand-alone generating capacity sufficient to meet all the electrical needs of the building A’’ ".w...electric utilties since the enactment of PURPA . An example of a recent small cogeneration application uses the 60-kW Thermo Electron cogeneration...utilities are naturally not enthusias- tic about cogeneration. However, PURPA was enacted to ensure that cogenerators receive just, reasonable, and
Analysis of long-time operation of micro-cogeneration unit with fuel cell
NASA Astrophysics Data System (ADS)
Patsch, Marek; Čaja, Alexander
2015-05-01
Micro-cogeneration is cogeneration with small performance, with maximal electric power up to 50 kWe. On the present, there are available small micro-cogeneration units with small electric performance, about 1 kWe, which are usable also in single family houses or flats. These micro-cogeneration units operate on principle of conventional combustion engine, Stirling engine, steam engine or fuel cell. Micro-cogeneration units with fuel cells are new progressive developing type of units for single family houses. Fuel cell is electrochemical device which by oxidation-reduction reaction turn directly chemical energy of fuel to electric power, secondary products are pure water and thermal energy. The aim of paper is measuring and evaluation of operation parameters of micro-cogeneration unit with fuel cell which uses natural gas as a fuel.
Survey of cogeneration: Advanced cogeneration research study
NASA Technical Reports Server (NTRS)
Slonski, M. L.
1983-01-01
The consumption of electricity, natural gas, or fuel oil was surveyed. The potential electricity that could be generated in the SCE service territory using cogeneration technology was estimated. It was found that an estimated 3700 MWe could potentially be generated in Southern California using cogenerated technology. It is suggested that current technology could provide 2600 MWe and advanced technology could provide 1100 MWe. Approximately 1600 MWt is considered not feasible to produce electricity with either current or advanced cogeneration technology.
77 FR 13593 - PowerSmith Cogeneration Project, LP; Notice of Request for Waiver
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-07
...] PowerSmith Cogeneration Project, LP; Notice of Request for Waiver Take notice that on February 27, 2012... CFR 292.205(c), PowerSmith Cogeneration Project, LP (PowerSmith) filed a Request for Waiver, for... Regulations for the topping- cycle cogeneration facility owned and operated by PowerSmith located in Oklahoma...
New developments in cogeneration: opening remarks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shuster, C.N.
1982-06-01
Cogeneration is defined as Total energy, that is, multiple use of a single source of energy. Dual utilization of radiation in an ancient bath in Pompeii is perhaps the earliest such use. Because of PURPA in 1978 development of small power production facilities and cogeneration is encouraged. A map shows the projected cogeneration facilities across the country in 1995.
NASA Technical Reports Server (NTRS)
Nainiger, J. J.; Burns, R. K.; Easley, A. J.
1982-01-01
A performance and operational economics analysis is presented for an integrated-gasifier, combined-cycle (IGCC) system to meet the steam and baseload electrical requirements. The effect of time variations in steam and electrial requirements is included. The amount and timing of electricity purchases from sales to the electric utility are determined. The resulting expenses for purchased electricity and revenues from electricity sales are estimated by using an assumed utility rate structure model. Cogeneration results for a range of potential IGCC cogeneration system sizes are compared with the fuel consumption and costs of natural gas and electricity to meet requirements without cogeneration. The results indicate that an IGCC cogeneration system could save about 10 percent of the total fuel energy presently required to supply steam and electrical requirements without cogeneration. Also for the assumed future fuel and electricity prices, an annual operating cost savings of 21 percent to 26 percent could be achieved with such a cogeneration system. An analysis of the effects of electricity price, fuel price, and system availability indicates that the IGCC cogeneration system has a good potential for economical operation over a wide range in these assumptions.
An assessment of advanced technology for industrial cogeneration
NASA Technical Reports Server (NTRS)
Moore, N.
1983-01-01
The potential of advanced fuel utilization and energy conversion technologies to enhance the outlook for the increased use of industrial cogeneration was assessed. The attributes of advanced cogeneration systems that served as the basis for the assessment included their fuel flexibility and potential for low emissions, efficiency of fuel or energy utilization, capital equipment and operating costs, and state of technological development. Over thirty advanced cogeneration systems were evaluated. These cogeneration system options were based on Rankine cycle, gas turbine engine, reciprocating engine, Stirling engine, and fuel cell energy conversion systems. The alternatives for fuel utilization included atmospheric and pressurized fluidized bed combustors, gasifiers, conventional combustion systems, alternative energy sources, and waste heat recovery. Two advanced cogeneration systems with mid-term (3 to 5 year) potential were found to offer low emissions, multi-fuel capability, and a low cost of producing electricity. Both advanced cogeneration systems are based on conventional gas turbine engine/exhaust heat recovery technology; however, they incorporate advanced fuel utilization systems.
Advanced cogeneration research study. Survey of cogeneration potential
NASA Technical Reports Server (NTRS)
Slonski, M. L.
1983-01-01
Fifty-five facilities that consumed substantial amounts of electricity, natural gas, or fuel oil were surveyed by telephone in 1983. The primary objective of the survey was to estimate the potential electricity that could be generated in the SCE service territory using cogeneration technology. An estimated 3667 MW sub e could potentially be generated using cogenerated technology. Of this total, current technology could provide 2569 MW sub p and advanced technology could provide 1098 MW sub e. Approximately 1611 MW sub t was considered not feasible to produce electricity with either current or advanced cogeneration technology.
Solar Cogeneration of Electricity and Hot Water at DoD Installations
2014-06-01
EW-201248) Solar Cogeneration of Electricity and Hot Water at DoD Installations June 2014 This report was prepared under contract to the...2014 ESTCP COST AND PERFORMANCE REPORT Solar Cogeneration of Electricity and Hot Water at DoD Installations W912HQ-12-C-0053 EW-201248Ratson...demonstrate an innovative hybrid electric/thermal solar cogeneration system, document performance and cost advantages, and develop financing models and
Solar Cogeneration of Electricity and Hot Water at DoD Installations
2014-05-01
the cogeneration system displaces more energy (the impact is not 4-5X because the GHG intensity factors for offsetting electricity generation and...FINAL REPORT Solar Cogeneration of Electricity and Hot Water at DoD Installations ESTCP Project EW-201248 MAY 2014 Ratson Morad... Cogeneration of Electricity and Hot Water at DoD Installations 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d
Feasibility of a small central cogenerated energy facility: Energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. N.
1982-10-01
The thermal economic feasibility of a small cogenerated energy facility designed to serve several industries in the Stockyards area was investigated. Cogeneration options included two dual fuel diesels and two gas turbines, all with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired boiler cases, also low sulphur coal and municipal refuse. For coal and refuse, the option of steam only without cogeneration was also assessed. The fired boiler cogeneration systems employed back pressure steam turbines. The refuse fired cases utilized electrical capacities, 8500 to 52,400 lbm/hr and 0 to 9.9 MW (e), respectively. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which was displaced was sold to Commonwealth Edison Company under PURPA (Public Utility Regulatory Policies Act). The facility was operated by a mutually owned corporation formed by the cogenerated power users.
The performance of residential micro-cogeneration coupled with thermal and electrical storage
NASA Astrophysics Data System (ADS)
Kopf, John
Over 80% of residential secondary energy consumption in Canada and Ontario is used for space and water heating. The peak electricity demands resulting from residential energy consumption increase the reliance on fossil-fuel generation stations. Distributed energy resources can help to decrease the reliance on central generation stations. Presently, distributed energy resources such as solar photovoltaic, wind and bio-mass generation are subsidized in Ontario. Micro-cogeneration is an emerging technology that can be implemented as a distributed energy resource within residential or commercial buildings. Micro-cogeneration has the potential to reduce a building's energy consumption by simultaneously generating thermal and electrical power on-site. The coupling of a micro-cogeneration device with electrical storage can improve the system's ability to reduce peak electricity demands. The performance potential of micro-cogeneration devices has yet to be fully realized. This research addresses the performance of a residential micro-cogeneration device and it's ability to meet peak occupant electrical loads when coupled with electrical storage. An integrated building energy model was developed of a residential micro-cogeneration system: the house, the micro-cogeneration device, all balance of plant and space heating components, a thermal storage device, an electrical storage device, as well as the occupant electrical and hot water demands. This model simulated the performance of a micro-cogeneration device coupled to an electrical storage system within a Canadian household. A customized controller was created in ESP-r to examine the impact of various system control strategies. The economic performance of the system was assessed from the perspective of a local energy distribution company and an end-user under hypothetical electricity export purchase price scenarios. It was found that with certain control strategies the micro-cogeneration system was able to improve the economic performance for both the end user and local distribution company.
AN ASSESSMENT OF CENTRAL-STATION CONGENERATION SYSTEMS FOR INDUSTRIAL COMPLEXES
This report assesses the potential for cogeneration system development based on an analysis of the economic, environmental, energy efficiency and social aspects of such systems. The cogeneration system is an application of the principle of cogeneration in which utility-sized powe...
18 CFR 292.304 - Rates for purchases.
Code of Federal Regulations, 2011 CFR
2011-04-01
... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small... discriminate against qualifying cogeneration and small power production facilities. (2) Nothing in this subpart... costs. (1) For purposes of this paragraph, “new capacity” means any purchase from capacity of a...
18 CFR 292.304 - Rates for purchases.
Code of Federal Regulations, 2013 CFR
2013-04-01
... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small... discriminate against qualifying cogeneration and small power production facilities. (2) Nothing in this subpart... costs. (1) For purposes of this paragraph, “new capacity” means any purchase from capacity of a...
18 CFR 292.304 - Rates for purchases.
Code of Federal Regulations, 2014 CFR
2014-04-01
... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small... discriminate against qualifying cogeneration and small power production facilities. (2) Nothing in this subpart... costs. (1) For purposes of this paragraph, “new capacity” means any purchase from capacity of a...
18 CFR 292.304 - Rates for purchases.
Code of Federal Regulations, 2012 CFR
2012-04-01
... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small... discriminate against qualifying cogeneration and small power production facilities. (2) Nothing in this subpart... costs. (1) For purposes of this paragraph, “new capacity” means any purchase from capacity of a...
NASA Technical Reports Server (NTRS)
Manvi, R.
1981-01-01
To assist DOE in establishing research and development funding priorities in the area of advanced energy conversion technoloy, researchers at the Jet Propulsion Laboratory studied those specific factors within various regions of the country that may influence cogeneration with advanced energy conversion systems. Regional characteristics of advanced technology cogeneration possibilities are discussed, with primary emphasis given to coal derived fuels. Factors considered for the study were regional industry concentration, purchased fuel and electricity prices, environmental constraints, and other data of interest to industrial cogeneration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil-or other fuel.... Total energy input means, with regard to a cogeneration unit, total energy of all forms supplied to the cogeneration unit, excluding energy produced by the cogeneration unit itself. Each form of energy supplied...
Code of Federal Regulations, 2010 CFR
2010-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil-or other fuel.... Total energy input means, with regard to a cogeneration unit, total energy of all forms supplied to the cogeneration unit, excluding energy produced by the cogeneration unit itself. Each form of energy supplied...
40 CFR 60.24 - Emission standards and compliance schedules.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fossil-or other fuel-fired combustion device used to produce heat and to transfer heat to recirculating... cogeneration unit, total energy of all forms supplied to the cogeneration unit, excluding energy produced by the cogeneration unit itself. Each form of energy supplied shall be measured by the lower heating...
40 CFR 60.24 - Emission standards and compliance schedules.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fossil-or other fuel-fired combustion device used to produce heat and to transfer heat to recirculating... cogeneration unit, total energy of all forms supplied to the cogeneration unit, excluding energy produced by the cogeneration unit itself. Each form of energy supplied shall be measured by the lower heating...
18 CFR 292.309 - Termination of obligation to purchase from qualifying facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small Power Production Facilities Under Section 210 of the Public... into a new contract or obligation to purchase electric energy from a qualifying cogeneration facility...
18 CFR 292.309 - Termination of obligation to purchase from qualifying facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small Power Production Facilities Under Section 210 of the Public... into a new contract or obligation to purchase electric energy from a qualifying cogeneration facility...
18 CFR 292.309 - Termination of obligation to purchase from qualifying facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small Power Production Facilities Under Section 210 of the Public... into a new contract or obligation to purchase electric energy from a qualifying cogeneration facility...
18 CFR 292.309 - Termination of obligation to purchase from qualifying facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small Power Production Facilities Under Section 210 of the Public... into a new contract or obligation to purchase electric energy from a qualifying cogeneration facility...
18 CFR 292.309 - Termination of obligation to purchase from qualifying facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small Power Production Facilities Under Section 210 of the Public... into a new contract or obligation to purchase electric energy from a qualifying cogeneration facility...
Prospects for constructing cogeneration stations equipped with back-pressure steam turbines
NASA Astrophysics Data System (ADS)
Ivanovskii, A. A.; Kultyshev, A. Yu.; Stepanov, M. Yu.
2014-12-01
The possibilities of using back-pressure cogeneration turbines developed on the basis of serially produced ones are considered together with the thermal process circuits in which such turbines are applied. Design versions and advantages of cogeneration stations in which the proposed process circuits are implemented are described.
Potential for cogeneration of heat and electricity in California industry, phase 1
NASA Technical Reports Server (NTRS)
Davis, H. S.; Gurfield, R. M.; Moretti, V. C.; Slonski, M. L.
1978-01-01
Information collected during an industrial survey of 12 selected plants was organized into four categories: technical, economic, environmental, and institutional. The technical aspects of industrial cogeneration are examined on a site-specific basis. The site-specific economics, environmental constraints, and institutional barriers that impact industrial cogeneration will be further investigated.
Feasibility of a medium-size central cogenerated energy facility, energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. W.
1982-09-01
The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.
Decision making for best cogeneration power integration into a grid
NASA Astrophysics Data System (ADS)
Al Asmar, Joseph; Zakhia, Nadim; Kouta, Raed; Wack, Maxime
2016-07-01
Cogeneration systems are known to be efficient power systems for their ability to reduce pollution. Their integration into a grid requires simultaneous consideration of the economic and environmental challenges. Thus, an optimal cogeneration power are adopted to face such challenges. This work presents a novelty in selectinga suitable solution using heuristic optimization method. Its aim is to optimize the cogeneration capacity to be installed according to the economic and environmental concerns. This novelty is based on the sensitivity and data analysis method, namely, Multiple Linear Regression (MLR). This later establishes a compromise between power, economy, and pollution, which leads to find asuitable cogeneration power, and further, to be integrated into a grid. The data exploited were the results of the Genetic Algorithm (GA) multi-objective optimization. Moreover, the impact of the utility's subsidy on the selected power is shown.
Rates for backup service under PURPA when the supplying utility has excess generating capacity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Under PURPA, cogenerators are entitled to receive backup service. It is often said that tariffs for backup service should reflect the low probability that an unscheduled outage will occur during system peak. This memorandum concludes that probabilistic analysis of contribution to coincident peak demand is not relevant under PURPA during periods in which a utility system is experiencing generating capacity surpluses, and that in such situations, backup rates should be designed so that should the customer insist on installing a cogeneration system, that the customer's contribution to fixed costs remains constant. The reason for this is to assure that prospectivemore » cogenerators receive appropriate pricing signals in their assessment of proposed cogeneration projects, and should they decide to install cogeneration facilities requiring backup service, to hold the remaining customers on the system harmless.« less
NASA Technical Reports Server (NTRS)
Nainiger, J. J.; Abbott, J. M.; Burns, R. K.
1981-01-01
In the cogeneration technology alternatives study (CTAS) a number of advanced coal fired systems were examined and systems using a integrated coal gasifier IGCC or a fluid bed combustor AFB were found to yield attractive cogeneration results in industrial cogeneration applications. A range of site requirements and cogeneration sizing strategies using ground rules based on CTAS were used in comparing an IGCC and an AFB. The effect of time variations in site requirements and the sensitivity to fuel and electricity price assumptions are examined. The economic alternatives of industrial or utility ownership are also considered. The results indicate that the IGCC system has potentially higher fuel and emission savings and could be an attractive option for utility ownership. The AFB steam turbine system has a potentially higher return on investment and could be attractive assuming industrial ownership.
Exergy analysis and simulation of a 30MW cogeneration cycle
NASA Astrophysics Data System (ADS)
Dev, Nikhil; Samsher; Kachhwaha, S. S.; Attri, Rajesh
2013-06-01
Cogeneration cycle is an efficient mean to recover the waste heat from the flue gases coming out of gas turbine. With the help of computer simulation, design parameters may be selected for the best performance of cogeneration cycle. In the present work a program is executed in software EES on the basis of mathematical modelling described in paper to study cogeneration cycle performance for different parameters. Results obtained are compared with the results available in literature and are found in good agreement with them. Real gas and water properties are inbuilt in the software. Results show that enthalpy of air entering the combustion chamber is higher than that of the flue gases at combustion chamber outlet. For different operative conditions, energy and exergy efficiencies follow similar trends; although, exergy efficiency values are always lower than the corresponding energy efficiency ones. From the results it is found that turbine outlet temperature (TIT) of 524°C is uniquely suited to efficient cogeneration cycle because it enables the transfer of heat from exhaust gas to the steam cycle to take place over a minimal temperature difference. This temperature range results in the maximum thermodynamic availability while operating with highest temperature and highest efficiency cogeneration cycle. Effect of cycle pressure ratio (CR), inlet air temperature (IAT) and water pressure at heat recovery steam generator (HRSG) inlet on the 30MW cogeneration cycle is also studied.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-29
... ``biomass'' was added so that cogeneration units could exclude biomass energy input in efficiency... the cogeneration unit definition to exclude energy input from biomass. At 326 IAC 24-1-2 (8), 326 IAC... ``Biomass'' in Reference to ``Cogeneration Unit'' H. The State's Complete CAIR Regulations I. NO X Reduction...
Advanced technology cogeneration system conceptual design study: Closed cycle gas turbines
NASA Technical Reports Server (NTRS)
Mock, E. A. T.; Daudet, H. C.
1983-01-01
The results of a three task study performed for the Department of Energy under the direction of the NASA Lewis Research Center are documented. The thermal and electrical energy requirements of three specific industrial plants were surveyed and cost records for the energies consumed were compiled. Preliminary coal fired atmospheric fluidized bed heated closed cycle gas turbine and steam turbine cogeneration system designs were developed for each industrial plant. Preliminary cost and return-on-equity values were calculated and the results compared. The best of the three sites was selected for more detailed design and evaluation of both closed cycle gas turbine and steam turbine cogeneration systems during Task II. Task III involved characterizing the industrial sector electrical and thermal loads for the 48 contiguous states, applying a family of closed cycle gas turbine and steam turbine cogeneration systems to these loads, and conducting a market penetration analysis of the closed cycle gas turbine cogeneration system.
Cogeneration systems and processes for treating hydrocarbon containing formations
Vinegar, Harold J [Bellaire, TX; Fowler, Thomas David [Houston, TX; Karanikas, John Michael [Houston, TX
2009-12-29
A system for treating a hydrocarbon containing formation includes a steam and electricity cogeneration facility. At least one injection well is located in a first portion of the formation. The injection well provides steam from the steam and electricity cogeneration facility to the first portion of the formation. At least one production well is located in the first portion of the formation. The production well in the first portion produces first hydrocarbons. At least one electrical heater is located in a second portion of the formation. At least one of the electrical heaters is powered by electricity from the steam and electricity cogeneration facility. At least one production well is located in the second portion of the formation. The production well in the second portion produces second hydrocarbons. The steam and electricity cogeneration facility uses the first hydrocarbons and/or the second hydrocarbons to generate electricity.
Aeroderivitive gas turbine-based cogeneration systems take off in airports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cull, R.
1993-06-01
Examples of airports are given that currently, or will in the future, rely on cogeneration to meet their power needs. Each of these cogeneration plants is located on the airport grounds, and each employs a GE aeroderivative gas turbine. These projects demonstrate the power range and versatility of gas turbines, since different size units are used for each application. 2 figs.
Thermionic cogeneration burner design
NASA Astrophysics Data System (ADS)
Miskolczy, G.; Goodale, D.; Moffat, A. L.; Morgan, D. T.
Since thermionic converters receive heat at very high temperatures (approximately 1800 K) and reject heat at moderately high temperatures (approximately 800 K), they are useful for cogeneration applications involving high temperature processes. The electric power from thermionic converters is produced as a high amperage, low-voltage direct current. An ideal cogeneration application would be to utilize the reject heat at the collector temperature and the electricity without power conditioning. A cogeneration application in the edible oil industry fulfills both of these requirements since both direct heat and hydrogen gas are required in the hydrogenation of the oils. In this application, the low-voltage direct current would be used in a hydrogen electrolyzer.
Analysis of carbon dioxide emission of gas fuelled cogeneration plant
NASA Astrophysics Data System (ADS)
Nordin, Adzuieen; Amin, M.; Majid, A.
2013-12-01
Gas turbines are widely used for power generation. In cogeneration system, the gas turbine generates electricity and the exhaust heat from the gas turbine is used to generate steam or chilled water. Besides enhancing the efficiency of the system, the process assists in reducing the emission of CO2 to the environment. This study analyzes the amount of CO2 emission by Universiti Teknologi Petronas gas fuelled cogeneration system using energy balance equations. The results indicate that the cogeneration system reduces the CO2 emission to the environment by 60%. This finding could encourage the power plant owners to install heat recovery systems to their respective plants.
Coal fired air turbine cogeneration
NASA Astrophysics Data System (ADS)
Foster-Pegg, R. W.
Fuel options and generator configurations for installation of cogenerator equipment are reviewed, noting that the use of oil or gas may be precluded by cost or legislation within the lifetime of any cogeneration equipment yet to be installed. A coal fueled air turbine cogenerator plant is described, which uses external combustion in a limestone bed at atmospheric pressure and in which air tubes are sunk to gain heat for a gas turbine. The limestone in the 26 MW unit absorbs sulfur from the coal, and can be replaced by other sorbents depending on types of coal available and stringency of local environmental regulations. Low temperature combustion reduces NOx formation and release of alkali salts and corrosion. The air heat is exhausted through a heat recovery boiler to produce process steam, then can be refed into the combustion chamber to satisfy preheat requirements. All parts of the cogenerator are designed to withstand full combustion temperature (1500 F) in the event of air flow stoppage. Costs are compared with those of a coal fired boiler and purchased power, and it is shown that the increased capital requirements for cogenerator apparatus will yield a 2.8 year payback. Detailed flow charts, diagrams and costs schedules are included.
Optimal Real-time Dispatch for Integrated Energy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Firestone, Ryan Michael
This report describes the development and application of a dispatch optimization algorithm for integrated energy systems (IES) comprised of on-site cogeneration of heat and electricity, energy storage devices, and demand response opportunities. This work is intended to aid commercial and industrial sites in making use of modern computing power and optimization algorithms to make informed, near-optimal decisions under significant uncertainty and complex objective functions. The optimization algorithm uses a finite set of randomly generated future scenarios to approximate the true, stochastic future; constraints are included that prevent solutions to this approximate problem from deviating from solutions to the actual problem.more » The algorithm is then expressed as a mixed integer linear program, to which a powerful commercial solver is applied. A case study of United States Postal Service Processing and Distribution Centers (P&DC) in four cities and under three different electricity tariff structures is conducted to (1) determine the added value of optimal control to a cogeneration system over current, heuristic control strategies; (2) determine the value of limited electric load curtailment opportunities, with and without cogeneration; and (3) determine the trade-off between least-cost and least-carbon operations of a cogeneration system. Key results for the P&DC sites studied include (1) in locations where the average electricity and natural gas prices suggest a marginally profitable cogeneration system, optimal control can add up to 67% to the value of the cogeneration system; optimal control adds less value in locations where cogeneration is more clearly profitable; (2) optimal control under real-time pricing is (a) more complicated than under typical time-of-use tariffs and (b) at times necessary to make cogeneration economic at all; (3) limited electric load curtailment opportunities can be more valuable as a compliment to the cogeneration system than alone; and (4) most of the trade-off between least-cost and least-carbon IES is determined during the system design stage; for the IES system considered, there is little difference between least-cost control and least-carbon control.« less
2011-05-01
Energy and water security/ independence; sustain leadership • Compliance and environmental stewardship (cannot impact training mission...reduction, with efforts underway and cogeneration opportunities 18.3% of energy consumed by facilities is produced or procured from renewable...payback timeframes of ɠ years on existing cogeneration plant and ɛ years on new cogeneration plant Renewable Energy • In FY2010, approximately 6.2% of
Industrial Cogeneration--What it is, How it Works, Its Potential.
1980-04-29
plant . Therefore, where industrial cogenerated electricity replaces central power- plant generated electricity, fewer emissions should be pro- duced...States Utilities Company plant located in the center of a petrochem - ical complex near Baton Rouge, Louisiana. Since 1929 the plant has produced steam and...utility emissions . Furthermore, since many existing utility plants burn oil, cogeneration might also lead to greater oil use than would otherwise be the
Air Force Third Party Financing Management Guide.
1984-05-01
lhe Public Utility Regulatory Policies Act of 1978 ( PURPA ) a l,s qualifying cogenerators to sell their power back to the utilities al the utilities...Conditions favorable to the sale of cogenerated or independrt~y produced power created by the Public Utility Regulatory Policies Act ( PURPA ) of 1978; o...electrical energy. The Public Utility Regulatory Policies Act of 1978 ( PURPA ) allows qualifying cogenerators to sell their powcr back to the
Cogeneration feasibility: Otis Elevator Company and Polychrome Corporation. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-05-01
The purpose of this study was to assess the feasibility of cogeneration at Otis Elevator Company and Polychrome Corporation located in Westchester County, New York. Each plant and its associated thermal and electrical load is reviewed. Three basic cycles for the cogeneration are investigated: power only, power generation with waste heat recovery, and combined cycle. Each case was assessed economically, beginning with a screening method to suggest those configurations most likely to be implemented and continuing through an assessment of the regulatory environment for cogeneration and an analysis of rate structures for buy back power, displaced power, and supplementing service.more » It is concluded that: for a plant designed to supply the combined loads of the two corporations, interconnection costs coupled to the coincidence of load result in unfavorable economics; for separate cogeneration plants, owned and operated by each individual corporation, energy consumption patterns and the current regulatory environment, in particular the existing and proposed cogeneration system rate structures, do not permit viable economics for the proposed plants; but if the proposed cycle were owned and operated by a new entity (neither Otis/Polychrome nor the utility), an economic scheme with marginal financial benefits can be developed and may be worthy of further study. (LEW)« less
Economics of Third-Party Central Heating Plants to Supply the Army
1992-01-01
Third-Party Gas-Fired Boiler Economics 52 APPENDIX C: Third-Party Gas Turbine Cogeneration Economics ( PURPA ) 58 APPENDIX D: Government Gas Turbine...Turbine Cogeneration Economics (Installation and PURPA Purchase) 76 APPENDIX G: Checklist for Identifying Optimal Third-Party Projects and Bidders 82...of scale 37 4 Relative costs of thermal energy from third-party cogeneration plants (@ 4C/kWh PURPA payment) 38 5 Comparison of life-cycle costs for
Cogeneration deferral rate and preemption under PURPA: a legal note
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spiewak, S.
The Public Utility Regulatory Policies Act (PURPA) is designed to benefit the ratepayer by using utility facilities as efficiently as possible. It does not ask states to encourage cogeneration or small power projects at the expense of utility efficiency. A legal analysis of the wording of PURPA shows that a deferral rate designed to retain customers who would otherwise turn to cogeneration or independent power supplies is legally consistent with PURPA's intent.
Potential for cogeneration of heat and electricity in California industry, phase 2
NASA Technical Reports Server (NTRS)
Davis, H. S.; Edelson, E.; Kashani, A. K.; Slonski, M. L.
1979-01-01
The nontechnical issues of industrial cogeneration for 12 California firms were analyzed under three categories of institutional settings: (1) industrial ownership without firm sales of power; (2) industrial ownership with firm sales of power; and (3) utility or third party ownership. Institutional issues were analyzed from the independent viewpoints of the primary parties of interest: the industrial firms, the electric utilities and the California Public utilities Commission. Air quality regulations and the agencies responsible for their promulgation were examined, and a life cycle costing model was used to evaluate the economic merits of representative conceptual cogeneration systems at these sites. Specific recommendations were made for mitigating measures and regulatory action relevant to industrial cogeneration in California.
Feasibility study for retrofitting biogas cogeneration systems to district heating in South Korea.
Chung, Mo; Park, Hwa-Choon
2015-08-01
A feasibility study was performed to assess the technical and economic merits of retrofitting biogas-based cogeneration systems to district heating networks. Three district heating plants were selected as candidates for accommodating heat recovery from nearby waste treatment stations, where a massive amount of biogas can be produced on a regular basis. The scenario involves constructing cogeneration systems in each waste treatment station and producing electricity and heat. The amounts of biogas production for each station are estimated based on the monthly treatment capacities surveyed over the most recent years. Heat produced by the cogeneration system is first consumed on site by the waste treatment system to keep the operating temperature at a proper level. If surplus heat is available, it will be transported to the nearest district heating plant. The year-round operation of the cogeneration system was simulated to estimate the electricity and heat production. We considered cost associated with the installation of the cogeneration system and piping as initial investments. Profits from selling electricity and recovering heat are counted as income, while costs associated with buying biogas are expenses. Simple payback periods of 2-10 years were projected under the current economic conditions of South Korea. We found that most of the proposed scenarios can contribute to both energy savings and environmental protection. © The Author(s) 2015.
NASA Astrophysics Data System (ADS)
Beausoleil-Morrison, Ian; Lombardi, Kathleen
The concurrent production of heat and electricity within residential buildings using solid-oxide fuel cell (SOFC) micro-cogeneration devices has the potential to reduce primary energy consumption, greenhouse gas emissions, and air pollutants. A realistic assessment of this emerging technology requires the accurate simulation of the thermal and electrical production of SOFC micro-cogeneration devices concurrent with the simulation of the building, its occupants, and coupled plant components. The calibration of such a model using empirical data gathered from experiments conducted with a 2.8 kW AC SOFC micro-cogeneration device is demonstrated. The experimental configuration, types of instrumentation employed, and the operating scenarios examined are treated. The propagation of measurement uncertainty into the derived quantities that are necessary for model calibration are demonstrated by focusing upon the SOFC micro-cogeneration system's gas-to-water heat exchanger. The calibration coefficients necessary to accurately simulate the thermal and electrical performance of this prototype device are presented and the types of analyses enabled to study the potential of the technology are demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deshaye, Joyce; Bloomquist, R.Gordon
1992-12-01
This guidebook focuses on cogeneration development. It is one of a series of four guidebooks recently prepared to introduce the energy developer to the federal, state and local agencies that regulate energy facilities in Idaho, Montana, Oregon, and Washington (the Bonneville Power Administration Service Territory). It was prepared specifically to help cogeneration developers obtain the permits, licenses and approvals necessary to construct and operate a cogeneration facility. The regulations, agencies and policies described herein are subject to change. Changes are likely to occur whenever energy or a project becomes a political issue, a state legislature meets, a preexisting popular ormore » valuable land use is thought threatened, elected and appointed officials change, and new directions are imposed on states and local governments by the federal government. Accordingly, cogeneration developers should verify and continuously monitor the status of laws and rules that might affect their plans. Developers are cautioned that the regulations described herein may only be a starting point on the road to obtaining all the necessary permits.« less
NASA Astrophysics Data System (ADS)
Asmar, Joseph Al; Lahoud, Chawki; Brouche, Marwan
2018-05-01
Cogeneration and trigeneration systems can contribute to the reduction of primary energy consumption and greenhouse gas emissions in residential and tertiary sectors, by reducing fossil fuels demand and grid losses with respect to conventional systems. The cogeneration systems are characterized by a very high energy efficiency (80 to 90%) as well as a less polluting aspect compared to the conventional energy production. The integration of these systems into the energy network must simultaneously take into account their economic and environmental challenges. In this paper, a decision-making strategy will be introduced and is divided into two parts. The first one is a strategy based on a multi-objective optimization tool with data analysis and the second part is based on an optimization algorithm. The power dispatching of the Lebanese electricity grid is then simulated and considered as a case study in order to prove the compatibility of the cogeneration power calculated by our decision-making technique. In addition, the thermal energy produced by the cogeneration systems which capacity is selected by our technique shows compatibility with the thermal demand for district heating.
NASA Technical Reports Server (NTRS)
Moretti, V. C.; Davis, H. S.; Slonski, M. L.
1978-01-01
In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass
NASA Astrophysics Data System (ADS)
Shchinnikov, P. A.; Tomilov, V. G.; Sinelnikov, D. S.
2017-01-01
The article considers some aspects of the research methodology of micro heat power plants based on internal combustion engines with air cooling and cogeneration based on energy balance equations and the laws of heat transfer. The research is conducted for such a setup based on the Hitachi internal combustion engine with 2.4 kW capacity. It has shown the efficiency of cogeneration use in the form of useful heat flow from air, cooling the cylinder head, with its further heating by utilizing the heat of flue gases in an additional plate heat exchanger. It has been shown that the cogeneration can save fuel costs 3-10 times compared with heat guns, depending on the duration of the setup use.
NASA Astrophysics Data System (ADS)
Oke, Shinichiro; Kemmoku, Yoshishige; Takikawa, Hirofumi; Sakakibara, Tateki
The reduction effect of life cycle CO2 emission is examined in case of introducing a PV/solar heat/cogeneration system into public welfare facilities(hotel and hospital). Life cycle CO2 emission is calculated as the sum of that when operating and that when manufacturing equipments. The system is operated with the dynamic programming method, into which hourly data of electric and heat loads, solar insolation, and atmospheric temperature during a year are input. The proposed system is compared with a conventional system and a cogeneration system. The life cycle CO2 emission of the PV/solar heat/cogeneration system is lower than that of the conventional system by 20% in hotel and by 14% in hospital.
A negotiation methodology and its application to cogeneration planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, S.M.; Liu, C.C.; Luu, S.
Power system planning has become a complex process in utilities today. This paper presents a methodology for integrated planning with multiple objectives. The methodology uses a graphical representation (Goal-Decision Network) to capture the planning knowledge. The planning process is viewed as a negotiation process that applies three negotiation operators to search for beneficial decisions in a GDN. Also, the negotiation framework is applied to the problem of planning for cogeneration interconnection. The simulation results are presented to illustrate the cogeneration planning process.
AFB/open cycle gas turbine conceptual design study
NASA Technical Reports Server (NTRS)
Dickinson, T. W.; Tashjian, R.
1983-01-01
Applications of coal fired atmospheric fluidized bed gas turbine systems in industrial cogeneration are identified. Based on site-specific conceptual designs, the potential benefits of the AFB/gas turbine system were compared with an atmospheric fluidized design steam boiler/steam turbine system. The application of these cogeneration systems at four industrial plant sites is reviewed. A performance and benefit analysis was made along with a study of the representativeness of the sites both in regard to their own industry and compared to industry as a whole. A site was selected for the conceptual design, which included detailed site definition, AFB/gas turbine and AFB/steam turbine cogeneration system designs, detailed cost estimates, and comparative performance and benefit analysis. Market and benefit analyses identified the potential market penetration for the cogeneration technologies and quantified the potential benefits.
AFB/open cycle gas turbine conceptual design study
NASA Astrophysics Data System (ADS)
Dickinson, T. W.; Tashjian, R.
1983-09-01
Applications of coal fired atmospheric fluidized bed gas turbine systems in industrial cogeneration are identified. Based on site-specific conceptual designs, the potential benefits of the AFB/gas turbine system were compared with an atmospheric fluidized design steam boiler/steam turbine system. The application of these cogeneration systems at four industrial plant sites is reviewed. A performance and benefit analysis was made along with a study of the representativeness of the sites both in regard to their own industry and compared to industry as a whole. A site was selected for the conceptual design, which included detailed site definition, AFB/gas turbine and AFB/steam turbine cogeneration system designs, detailed cost estimates, and comparative performance and benefit analysis. Market and benefit analyses identified the potential market penetration for the cogeneration technologies and quantified the potential benefits.
Efficiency Assessment of Support Mechanisms for Wood-Fired Cogeneration Development in Estonia
NASA Astrophysics Data System (ADS)
Volkova, Anna; Siirde, Andres
2010-01-01
There are various support mechanisms for wood-fired cogeneration plants, which include both support for cogeneration development and stimulation for increasing consumption of renewable energy sources. The efficiency of these mechanisms is analysed in the paper. Overview of cogeneration development in Estonia is given with the focus on wood-fired cogeneration. Legislation acts and amendments, related to cogeneration support schemes, were described. For evaluating the efficiency of support mechanisms an indicator - fuel cost factor was defined. This indicator includes the costs related to the chosen fuel influence on the final electricity generation costs without any support mechanisms. The wood fuel cost factors were compared with the fuel cost factors for peat and oil shale. For calculating the fuel cost factors, various data sources were used. The fuel prices data were based on the average cost of fuels in Estonia for the period from 2000 till 2008. The data about operating and maintenance costs, related to the fuel type in the case of comparing wood fuel and oil shale fuel were taken from the CHP Balti and Eesti reports. The data about operating and maintenance costs used for peat and wood fuel comparison were taken from the Tallinn Elektrijaam reports. As a result, the diagrams were built for comparing wood and its competitive fuels. The decision boundary lines were constructed on the diagram for the situation, when no support was provided for wood fuels and for the situations, when various support mechanisms were provided during the last 12 years.
Utility involvement in cogeneration and small power production since PURPA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hallaron, S.A.
One of the objectives of PURPA was more efficient energy production through cogeneration and the use of renewable resources. Under PURPA regulations, cogeneration and small power-producing plants may file for qualifying status to receive benefits allowed by the National Energy Act. There has been a steady increase in the number of qualifying facilities (QFs) and some electric utilities have increased ownership of small power-producing facilities as well as electric purchases from QFs. QFs are not only exempt from federal and state utility regulations under PURPA, but they also may be eligible for an exemption from the provisions of the Fuelmore » Use Act of 1978 which prohibits or limits use of oil and natural gas in power plants and other major fuel-burning installations. To obtain QF status under PURPA, small power-producing facilities are limited to a capacity of 80 MW or less and must use some combination of biomass, waste, geothermal, or other renewable resource as the primary energy source. Cogenerators are not limited in size or fuel. The purchase of electricity from cogenerators and small power producers can be an attractive alternative for utilities in meeting future demands.« less
40 CFR 60.2030 - Who implements and enforces this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... qualifying small power production facility or cogeneration facility under § 60.2020(e) or (f) is combusting... qualifying small power production facility or cogeneration facility under § 60.2020(e) or (f) is combusting...
Micro-cogeneration units based on Stirling engine for heating and their real operation
NASA Astrophysics Data System (ADS)
Čierny, Jaroslav; Patsch, Marek
2014-08-01
This article was deal with micro-cogeneration units based on Stirling engine. We watched problematic of real working Stirling engine. The article also contain hookup of unit constructed at University of Zilina.
NASA Technical Reports Server (NTRS)
Sagerman, G. D.; Barna, G. J.; Burns, R. K.
1979-01-01
An overview of the organization and methodology of the Cogeneration Technology Alternatives Study is presented. The objectives of the study were to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the future and to assess the advantages of advanced technology systems compared to those systems commercially available today. Advanced systems studied include steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics. Steam turbines, open cycle gas turbines, combined cycles, and diesel engines were also analyzed in versions typical of today's commercially available technology to provide a base against which to measure the advanced systems. Cogeneration applications in the major energy consuming manufacturing industries were considered. Results of the study in terms of plant level energy savings, annual energy cost savings and economic attractiveness are presented for the various energy conversion systems considered.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
Computer generated data on the performance of the cogeneration energy conversion system are presented. Performance parameters included fuel consumption and savings, capital costs, economics, and emissions of residual fired process boilers.
77 FR 29999 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-21
.... Applicants: Lowell Cogeneration Company Limited Partnership, Power City Partners, L.P. Description... Lowell Cogeneration Company Limited Partnership, et al. Filed Date: 5/10/12. Accession Number: 20120510... rate filings: Docket Numbers: ER12-1742-001. Applicants: International Transmission Company...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oland, CB
Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributedmore » Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that only produce steam or hot water for process applications. By using fuel energy for both power and heat production, CHP systems can be very energy efficient and have the potential to produce electricity below the price charged by the local power provider. Another important incentive for applying cogeneration technology is to reduce or eliminate dependency on the electrical grid. For some industrial processes, the consequences of losing power for even a short period of time are unacceptable. The primary objective of the guide is to present information needed to evaluate the viability of cogeneration for new or existing industrial, commercial, and institutional (ICI) boiler installations and to make informed CHP equipment selection decisions. Information presented is meant to help boiler owners and operators understand the potential benefits derived from implementing a CHP project and recognize opportunities for successful application of cogeneration technology. Topics covered in the guide follow: (1) an overview of cogeneration technology with discussions about benefits of applying cogeneration technology and barriers to implementing cogeneration technology; (2) applicable federal regulations and permitting issues; (3) descriptions of prime movers commonly used in CHP applications, including discussions about design characteristics, heat-recovery options and equipment, fuels and emissions, efficiency, maintenance, availability, and capital cost; (4) electrical generators and electrical interconnection equipment; (5) cooling and dehumidification equipment; (6) thermodynamic cycle options and configurations; (7) steps for evaluating the technical and economic feasibility of applying cogeneration technology; and (8) information sources.« less
76 FR 44319 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-25
.... Applicants: Dartmouth Power Associates Limited Partnership, Camden Plant Holding, LLC, Pedricktown Cogeneration Company LP, Elmwood Park Power LLC, Newark Bay Cogeneration Partnership, L.P, York Generation Company LLC, Bayonne Plant Holding, LLC. Description: Application for the Authorization for Disposition of...
18 CFR 292.306 - Interconnection costs.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Interconnection costs... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small Power Production Facilities Under Section 210 of the Public Utility Regulatory Policies Act of 1978...
18 CFR 292.304 - Rates for purchases.
Code of Federal Regulations, 2010 CFR
2010-04-01
... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small... reasonable to the electric consumer of the electric utility and in the public interest; and (ii) Not... requires any electric utility to pay more than the avoided costs for purchases. (b) Relationship to avoided...
NASA Technical Reports Server (NTRS)
1980-01-01
Data and information established for heat sources balance of plant items, thermal energy storage, and heat pumps are presented. Design case descriptions are given along with projected performance values. Capital cost estimates for representative cogeneration plants are also presented.
77 FR 58365 - Commission Information Collection Activities (FERC-912); Comment Request; Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
... collection, FERC-912, Cogeneration and Small Power Production, PURPA Section 210(m) Regulations for...-0873. SUPPLEMENTARY INFORMATION: Title: FERC-912, Cogeneration and Small Power Production, PURPA... the Public Utility Regulatory Policies Act of 1978 (PURPA) by adding subsection ``(m)'' that provides...
NASA Astrophysics Data System (ADS)
Kubasco, A. J.
1991-07-01
The objective of Gas Engine Heat Recovery Unit was to design, fabricate, and test an efficient, compact, and corrosion resistant heat recovery unit (HRU) for use on exhaust of natural gas-fired reciprocating engine-generator sets in the 50-500 kW range. The HRU would be a core component of a factory pre-packaged cogeneration system designed around component optimization, reliability, and efficiency. The HRU uses finned high alloy, stainless steel tubing wound into a compact helical coil heat exchanger. The corrosion resistance of the tubing allows more heat to be taken from the exhaust gas without fear of the effects of acid condensation. One HRU is currently installed in a cogeneration system at the Henry Ford Hospital Complex in Dearborn, Michigan. A second unit underwent successful endurance testing for 850 hours. The plan was to commercialize the HRU through its incorporation into a Caterpillar pre-packaged cogeneration system. Caterpillar is not proceeding with the concept at this time because of a downturn in the small size cogeneration market.
Code of Federal Regulations, 2010 CFR
2010-04-01
....310 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE PUBLIC UTILITY REGULATORY POLICIES ACT OF 1978 REGULATIONS UNDER SECTIONS... PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying Cogeneration and Small...
18 CFR 292.204 - Criteria for qualifying small power production facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Criteria for qualifying small power production facilities. 292.204 Section 292.204 Conservation of Power and Water Resources... OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small...
18 CFR 292.204 - Criteria for qualifying small power production facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Criteria for qualifying small power production facilities. 292.204 Section 292.204 Conservation of Power and Water Resources... OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small...
18 CFR 292.204 - Criteria for qualifying small power production facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Criteria for qualifying small power production facilities. 292.204 Section 292.204 Conservation of Power and Water Resources... OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... standard. For any topping-cycle cogeneration facility, the useful thermal energy output of the facility... thermal energy output, during the 12-month period beginning with the date the facility first produces... total energy input of natural gas and oil to the facility; or (B) If the useful thermal energy output is...
Cogenerating a Competency-based HRM Degree: A Model and Some Lessons from Experience.
ERIC Educational Resources Information Center
Wooten, Kevin C.; Elden, Max
2001-01-01
A competency-based degree program in human resource management was co-generated by six groups of stakeholders who synthesized competency models using group decision support software. The program focuses on core human resource processes, general business management, strategic decision making and problem solving, change management, and personal…
SUNY Contracts for Cogeneration.
ERIC Educational Resources Information Center
Freeman, Laurie
1996-01-01
The State University of New York-Stony Brook forged a public-private partnership to fund a new plan for cogeneration, a two-step process that uses one fuel source--natural gas--to make two forms of energy. The agreement is designed to free the university from the need to make ongoing capital investment in its utility infrastructure. (MLF)
1985-11-01
Public Utilities Regulatory Policies Act ( PURPA ) criteria for classification as a "Qualifying Facility" (QF). 11. Visual effect of intermittent...the public utility of electric power produced by the cogenerator. The operating standard of PURPA requires that a new QF must produce at least 5% of
Code of Federal Regulations, 2014 CFR
2014-04-01
... PRODUCTION AND COGENERATION Exemption of Qualifying Small Power Production Facilities and Cogeneration... small power production facility with a power production capacity over 30 megawatts if such facility produces electric energy solely by the use of biomass as a primary energy source. (b) Exemption from the...
Code of Federal Regulations, 2012 CFR
2012-04-01
... PRODUCTION AND COGENERATION Exemption of Qualifying Small Power Production Facilities and Cogeneration... small power production facility with a power production capacity over 30 megawatts if such facility produces electric energy solely by the use of biomass as a primary energy source. (b) Exemption from the...
Code of Federal Regulations, 2013 CFR
2013-04-01
... PRODUCTION AND COGENERATION Exemption of Qualifying Small Power Production Facilities and Cogeneration... small power production facility with a power production capacity over 30 megawatts if such facility produces electric energy solely by the use of biomass as a primary energy source. (b) Exemption from the...
NASA Technical Reports Server (NTRS)
Sagerman, G. D.; Barna, G. J.; Burns, R. K.
1979-01-01
The Cogeneration Technology Alternatives Study (CTAS), a program undertaken to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the 1985-2000 time period, is described, and preliminary results are presented. Two cogeneration options are included in the analysis: a topping application, in which fuel is input to the energy conversion system which generates electricity and waste heat from the conversion system is used to provide heat to the process, and a bottoming application, in which fuel is burned to provide high temperature process heat and waste heat from the process is used as thermal input to the energy conversion system which generates energy. Steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics are examined. Expected plant level energy savings, annual energy cost savings, and other results of the economic analysis are given, and the sensitivity of these results to the assumptions concerning fuel prices, price of purchased electricity and the potential effects of regional energy use characteristics is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leibler, J.; Luxton, R.; Ostberg, P.
This article describes the first major privatization effort to be completed at John F. Kennedy International Airport. The airport owner and operator, the Port Authority of New York and New Jersey, decided to seek private sector involvement in a capital-intensive project to expand and upgrade the airport`s heating and air conditioning facilities and construct a new cogeneration plant. Kennedy International Airport Cogeneration (KIAC) Partners, a partnership between Gas Energy Incorporated of New York and Community Energy Alternatives of New Jersey, was selected to develop an energy center to supply electricity and hot and chilled water to meet the airport`s growingmore » energy demand. Construction of a 110 MW cogeneration plant, 7,000 tons of chilled water equipment, and 30,000 feet of hot water delivery piping started immediately. JFK Airport`s critical international position called for this substantial project to be developed almost invisibly; no interruption in heating and air conditioning service and no interference in the airport`s active operations could be tolerated. Commercial operation was achieved in February 1995.« less
NASA Astrophysics Data System (ADS)
Lung, Chienru; Miyake, Shota; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi; Momose, Toshinari; Hayakawa, Hideki
For the past few years, a hybrid generation system including solar panel and gas cogeneration is being used for residential houses. Solar panels can generate electronic power at daytime; meanwhile, it cannot generate electronic power at night time. But the power consumption of residential houses usually peaks in the evening. The gas engine cogeneration system can generate electronic power without such a restriction, and it also can generate heat power to warm up house or to produce hot water. In this paper, we propose the solar panel and gas engine co-generation hybrid system with an energy storage device that is combined by dc bus. If a black out occurs, the system still can supply electronic power for special house loads. We propose the control scheme for the system which are related with the charging level of the energy storage device, the voltage of the utility grid which can be applied both grid connected and stand alone operation. Finally, we carried out some experiments to demonstrate the system operation and calculation for loss estimation.
Cogeneration Technology Alternatives Study (CTAS) Volume 5: Analytical approach and results
NASA Technical Reports Server (NTRS)
1980-01-01
Data and information in the area of advanced energy conversion systems for industrial cogeneration applications in the 1985 to 2000 time period are provided. Six current and thirty-six advanced energy conversion systems were defined and combined with appropriate balance of plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a framework for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. Various cogeneration strategies were analyzed and both topping and bottoming (using industrial by-product heat) applications were included. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Typically fuel energy savings of 10 to 25 percent were predicted compared to traditional on site furnaces and utility electricity. Gas turbines and combined cycles indicated high overall annual cost savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal derived fuels, or coal with advanced fluid bed combustion or on site gasification systems.
Dahiya, Shikha; Sarkar, Omprakash; Swamy, Y V; Venkata Mohan, S
2015-04-01
Fermentation experiments were designed to elucidate the functional role of the redox microenvironment on volatile fatty acid (VFA, short chain carboxylic acid) production and co-generation of biohydrogen (H2). Higher VFA productivity was observed at pH 10 operation (6.3g/l) followed by pH 9, pH 6, pH 5, pH 7, pH 8 and pH 11 (3.5 g/l). High degree of acidification, good system buffering capacity along with co-generation of higher H2 production from food waste was also noticed at alkaline condition. Experiments illustrated the role of initial pH on carboxylic acids synthesis. Alkaline redox conditions assist solubilization of carbohydrates, protein and fats and also suppress the growth of methanogens. Among the carboxylic acids, acetate fraction was higher at alkaline condition than corresponding neutral or acidic operations. Integrated process of VFA production from waste with co-generation of H2 can be considered as a green and sustainable platform for value-addition. Copyright © 2015 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-04-01
... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... 201 AND 210 OF THE PUBLIC UTILITY REGULATORY POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small Power Production Facilities § 292.208 Special...
Code of Federal Regulations, 2011 CFR
2011-04-01
... for hydroelectric small power production facilities located at a new dam or diversion. 292.208 Section... 201 AND 210 OF THE PUBLIC UTILITY REGULATORY POLICIES ACT OF 1978 WITH REGARD TO SMALL POWER PRODUCTION AND COGENERATION Qualifying Cogeneration and Small Power Production Facilities § 292.208 Special...
Congeneration feasibility: Otis Elevator Company and Polychrome Corporation. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, H.
1982-05-01
This report summarizes an investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY. Existing electrical- and steam-producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return-on-investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, thismore » detailed study provides valuable insight into the types of problems encountered when considering cogeneration feasibility.« less
NASA Astrophysics Data System (ADS)
Aronson, K. E.; Brodov, Yu. M.; Novoselov, V. B.
2012-12-01
Generalized results from the work on developing elements of a comprehensive system for monitoring technical state of the equipment of cogeneration turbines are presented. The parameters of the electrohydraulic turbine control system are considered together with a number of problems concerned with assessing the state of condensers and delivery water heaters.
NASA Astrophysics Data System (ADS)
Cioccolanti, L.; Arteconi, A.; Bartolini, C. M.; Polonara, F.
2017-11-01
Nowadays the thermal energy demand in the industrial sector is usually satisfied by means of fire tube boilers while electricity is supplied from the grid. Alternatively cogeneration units could be adopted for thermal and electrical energy self-production, whilst installing boilers only as back-up units. However, even when cogeneration is profitable, it is not widespread because industries are usually unwilling to accept cogeneration plants for reliability and high investment costs issues. In this work a system aimed at overcoming the above mentioned market difficulties is proposed. It consists of an innovative coupling of a combined heat and power unit with a modified fire tube boiler. In particular, a CFD analysis was carried out by the authors in order to address the most critical aspects related with the coupling of the two systems. More precisely, the following aspects were evaluated in detail: (i) pressure losses of the exhausts going from the prime mover to the boiler due to the sudden cross-section area variations; (ii) thermal power recoverable from the exhausts in the tubes of the boiler; (iii) dependence of the system on the final users’ specification.
CO2 Reduction Effect of the Utilization of Waste Heat and Solar Heat in City Gas System
NASA Astrophysics Data System (ADS)
Okamura, Tomohito; Matsuhashi, Ryuji; Yoshida, Yoshikuni; Hasegawa, Hideo; Ishitani, Hisashi
We evaluate total energy consumption and CO2 emissions in the phase of the city gas utilization system from obtaining raw materials to consuming the product. First, we develop a simulation model which calculates CO2 emissions for monthly and hourly demands of electricity, heats for air conditioning and hot-water in a typical hospital. Under the given standard capacity and operating time of CGS, energy consumption in the equipments is calculated in detail considering the partial load efficiency and the control by the temperature of exhaust heat. Then, we explored the optimal size and operation of city gas system that minimizes the life cycle CO2 emissions or total cost. The cost-effectiveness is compared between conventional co-generation, solar heat system, and hybrid co-generation utilizing solar heat. We formulate a problem of mixed integer programming that includes integral parameters that express the state of system devices such as on/off of switches. As a result of optimization, the hybrid co-generation can reduce annual CO2 emissions by forty-three percent compared with the system without co-generation. Sensitivity for the scale of CGS on CO2 reduction and cost is also analyzed.
Conceptual design study of a coal gasification combined-cycle powerplant for industrial cogeneration
NASA Astrophysics Data System (ADS)
Bloomfield, H. S.; Nelson, S. G.; Straight, H. F.; Subramaniam, T. K.; Winklepleck, R. G.
1981-03-01
A conceptual design study was conducted to assess technical feasibility, environmental characteristics, and economics of coal gasification. The feasibility of a coal gasification combined cycle cogeneration powerplant was examined in response to energy needs and to national policy aimed at decreasing dependence on oil and natural gas. The powerplant provides the steam heating and baseload electrical requirements while serving as a prototype for industrial cogeneration and a modular building block for utility applications. The following topics are discussed: (1) screening of candidate gasification, sulfur removal and power conversion components; (2) definition of a reference system; (3) quantification of plant emissions and waste streams; (4) estimates of capital and operating costs; and (5) a procurement and construction schedule. It is concluded that the proposed powerplant is technically feasible and environmentally superior.
Development of Residential SOFC Cogeneration System
NASA Astrophysics Data System (ADS)
Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki
2011-06-01
Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.
Conceptual design study of a coal gasification combined-cycle powerplant for industrial cogeneration
NASA Technical Reports Server (NTRS)
Bloomfield, H. S.; Nelson, S. G.; Straight, H. F.; Subramaniam, T. K.; Winklepleck, R. G.
1981-01-01
A conceptual design study was conducted to assess technical feasibility, environmental characteristics, and economics of coal gasification. The feasibility of a coal gasification combined cycle cogeneration powerplant was examined in response to energy needs and to national policy aimed at decreasing dependence on oil and natural gas. The powerplant provides the steam heating and baseload electrical requirements while serving as a prototype for industrial cogeneration and a modular building block for utility applications. The following topics are discussed: (1) screening of candidate gasification, sulfur removal and power conversion components; (2) definition of a reference system; (3) quantification of plant emissions and waste streams; (4) estimates of capital and operating costs; and (5) a procurement and construction schedule. It is concluded that the proposed powerplant is technically feasible and environmentally superior.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pals, C.M.
1998-12-31
A liberal arts college in Los Angeles was plagued by inefficient use of low-pressure (LP) steam produced by its two 150 kWe cogeneration units. Poor integration of the LP cogen system into the college`s existing high-pressure (HP) steam boiler plant led to under-utilization of cogenerated steam during the non-space-heating season. Six years of inefficient operation was estimated to have cost the college $750,000 in lost utility and maintenance savings. To improve steam-plant operations, the college`s facilities management staff implemented a plan to convert HP steam loads to LP, replace HP steam boilers with LP equipment, and improve the use ofmore » cogenerated steam through the installation of a hot water thermal energy storage (TES) system. A study was commissioned that identified the plant`s peak winter steam requirements and the typical steam profile for the non-space-heating season. Data from this work helped draw two conclusions: (1) converting HP steam loads to LP would boost demand for cogenerated steam, and (2) a hot water thermal energy storage (TES) system could further utilize a portion of remaining excess cogen steam for the manufacture and storage of the kitchen`s domestic water for use during peak steam demand periods. Combined, these two measures were estimated to improve utilization of cogenerated LP steam by 11,000 pounds (5,000 kg) per day and reduce boiler fuel consumption by 40,000 therms (4,220,000 MJ) each season. In addition to this work, a major plant renovation project was completed, which included the replacement of a 60-year-old, 280 bhp (2,747 kW) HP steam boiler, with two new LP boilers. Conversion to LP and the start-up of the hot water TES was completed in May 1997. During the first year of operation, after the improvement, boiler gas savings exceeded 52,000 therms (5,486,000 MJ). Maintenance savings of $100,000 were also accrued by eliminating licensed HP boiler operators. All construction work described to improve energy efficiency and rehabilitate the steam plant cost $687,000 and is on track to produce a simple payback of 5.5 years. Overall, this paper demonstrates the energy and cost inefficiencies that may result if the opportunities to use waste heat from cogeneration systems are incorrectly identified.« less
NASA Astrophysics Data System (ADS)
Dubey, M.; Chandra, H.; Kumar, Anil
2016-02-01
A thermal modelling for the performance evaluation of gas turbine cogeneration system with reheat is presented in this paper. The Joule-Brayton cogeneration reheat cycle is based on the total useful energy rate (TUER) has been optimised and the efficiency at the maximum TUER is determined. The variation of maximum dimensionless TUER and efficiency at maximum TUER with respect to cycle temperature ratio have also been analysed. From the results, it has been found that the dimensionless maximum TUER and the corresponding thermal efficiency decrease with the increase in power to heat ratio. The result also shows that the inclusion of reheat significantly improves the overall performance of the cycle. From the thermodynamic performance point of view, this methodology may be quite useful in the selection and comparison of combined energy production systems.
Competition and Cooperation of Distributed Generation and Power System
NASA Astrophysics Data System (ADS)
Miyake, Masatoshi; Nanahara, Toshiya
Advances in distributed generation technologies together with the deregulation of an electric power industry can lead to a massive introduction of distributed generation. Since most of distributed generation will be interconnected to a power system, coordination and competition between distributed generators and large-scale power sources would be a vital issue in realizing a more desirable energy system in the future. This paper analyzes competitions between electric utilities and cogenerators from the viewpoints of economic and energy efficiency based on the simulation results on an energy system including a cogeneration system. First, we examine best response correspondence of an electric utility and a cogenerator with a noncooperative game approach: we obtain a Nash equilibrium point. Secondly, we examine the optimum strategy that attains the highest social surplus and the highest energy efficiency through global optimization.
System effects of primary energy reduction connected with operation of the CHP plants
NASA Astrophysics Data System (ADS)
Ziębik, Andrzej; Gładysz, Paweł
2017-06-01
The paper is devoted to explication of one of the advantages of heat and electricity cogeneration, rarely considered in technical literature. Usually attention is paid to the fact that heat losses of the heat distribution network are less severe in the case of cogeneration of heat in comparison with its separate production. But this conclusion is also true in other cases when the internal consumption of heat is significant. In this paper it has been proved in the case of two examples concerning trigeneration technology with an absorption chiller cooperating with a combined heat and power (CHP) plant and CHP plant integrated with amine post-combustion CO2 processing unit. In both considered cases it might be said that thanks to cogeneration we have to do with less severe consequences of significant demand of heat for internal purposes.
Space Heating Load Estimation Procedure for CHP Systems sizing
NASA Astrophysics Data System (ADS)
Vocale, P.; Pagliarini, G.; Rainieri, S.
2015-11-01
Due to its environmental and energy benefits, the Combined Heat and Power (CHP) represents certainly an important measure to improve energy efficiency of buildings. Since the energy performance of the CHP systems strongly depends on the fraction of the useful cogenerated heat (i.e. the cogenerated heat that is actually used to meet building thermal demand), in building applications of CHP, it is necessary to know the space heating and cooling loads profile to optimise the system efficiency. When the heating load profile is unknown or difficult to calculate with a sufficient accuracy, as may occur for existing buildings, it can be estimated from the cumulated energy uses by adopting the loads estimation procedure (h-LEP). With the aim to evaluate the useful fraction of the cogenerated heat for different operating conditions in terms of buildings characteristics, weather data and system capacity, the h-LEP is here implemented with a single climate variable: the hourly average dry- bulb temperature. The proposed procedure have been validated resorting to the TRNSYS simulation tool. The results, obtained by considering a building for hospital use, reveal that the useful fraction of the cogenerated heat can be estimated with an average accuracy of ± 3%, within the range of operative conditions considered in the present study.
Reconstruction of cogeneration plants equipped with LMZ R-50-130 steam turbines
NASA Astrophysics Data System (ADS)
Ermolaev, V. V.; Gudkov, N. N.; Shklyar, A. I.; Dudin, N. N.; Adamson, D. A.; Babiev, A. N.; Koshelev, S. A.; Solov'ev, A. K.; Miroshnichenko, S. A.
2009-04-01
The problems of how to use backpressure turbines underloaded for objective reasons at industrial cogeneration plants (CPs) are analyzed. The means of modernization of R-50-130 turbines implemented by the Teploenergoservis group of companies, which make it possible to meet the changed requirements for power and heat supply from a CP equipped with R-50-130 turbines and to increase productivity of CP fixed assets, are described.
Cogeneration Technology Alternatives Study (CTAS). Volume 1: Summary
NASA Technical Reports Server (NTRS)
Barna, G. J.; Burns, R. K.; Sagerman, G. D.
1980-01-01
Various advanced energy conversion systems that can use coal or coal-derived fuels for industrial cogeneration applications were compared to provide information needed by DOE to establish research and development funding priorities for advanced-technology systems that could significantly advance the use of coal or coal-derived fuels in industrial cogeneration. Steam turbines, diesel engines, open-cycle gas turbines, combined cycles, closed-cycle gas turbines, Stirling engines, phosphoric acid fuel cells, molten carbonate fuel cells, and thermionics were studied with technology advancements appropriate for the 1985-2000 time period. The various advanced systems were compared and evaluated for wide diversity of representative industrial plants on the basis of fuel energy savings, annual energy cost savings, emissions savings, and rate of return on investment as compared with purchasing electricity from a utility and providing process heat with an on-site boiler. Also included in the comparisons and evaluations are results extrapolated to the national level.
Cogeneration Technology Alternatives Study (CTAS). Volume 2: Comparison and evaluation of results
NASA Technical Reports Server (NTRS)
1984-01-01
CTAS compared and evaluated various advanced energy conversion systems that can use coal or coal-derived fuels for industrial cogeneration applications. The principal aim of the study was to provide information needed by DOE to establish research and development (R&D) funding priorities for advanced-technology systems that could significantly advance the use of coal or coal-derived fuels in industrial cogeneration. Steam turbines, diesel engines, open-cycle gas turbines, combined cycles, closed-cycle gas turbines, Stirling engines, phosphoric acid fuel cells, molten carbonate fuel cells, and thermionics were studied with technology advancements appropriate for the 1985-2000 time period. The various advanced systems were compared and evaluated for a wide diversity of representative industrial plants on the basis of fuel energy savings, annual energy cost savings, emissions savings, and rate of return on investment (ROI) as compared with purchasing electricity from a utility and providing process heat with an on-site boiler.
Proceedings of the third annual Nevada energy forum and exposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-01-01
This book presents the papers given at a forum on energy conservation. The papers include subjects on the following topics: third party financing; heat recovery and indirect evaporative cooling; computer literacy; practical power factor survey methodology; the measured energy performance of buildings; casino cogeneration; employees and energy conservation; daylighting; infrared heating; peak shaving and cogeneration. These subjects were orientated toward the management, purchasing and engineering professions and coincided with the forum goal of promoting energy conservation literacy.
HOMER: The Micropower Optimization Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2004-03-01
HOMER, the micropower optimization model, helps users to design micropower systems for off-grid and grid-connected power applications. HOMER models micropower systems with one or more power sources including wind turbines, photovoltaics, biomass power, hydropower, cogeneration, diesel engines, cogeneration, batteries, fuel cells, and electrolyzers. Users can explore a range of design questions such as which technologies are most effective, what size should components be, how project economics are affected by changes in loads or costs, and is the renewable resource adequate.
An assessment of the industrial cogeneration market for parabolic dish systems
NASA Technical Reports Server (NTRS)
Doane, J. W.
1981-01-01
The value analysis technique used is straightforward. Maximum allowable life-cycle system cost for the cogeneration system is determined as the sum of the present value of fuels displaced plus the present value of revenues from exported power. Each conventional fuel displaced is described by a unit cost in the first year, a uniform annual consumption rate, and a uniform annual escalation rate for unit cost. Exported energy flows are treated the same as displaced energy.
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE 2000). Volume Four
2000-01-13
Significantly Varying Demand of Heat and Power 1347 D. Hein and K. Kwanka T2. Thermodynamic Analysis and Sensitivity Studies on Braysson cycle Using...to Volumes 1-4 T. Cycle Analysis 1346 CHENG CYCLE COGENERATION FOR A SIGNIFICANTLY VARYING DEMAND OF HEAT AND POWER Dietmar Hein, Klaus Kwanka...significantly varying demand of heat and power a Cheng Cycle gas turbine cogeneration plant was installed. By injecting steam, produced by the heat
Layouts of trigeneration plants for centralized power supply
NASA Astrophysics Data System (ADS)
Klimenko, A. V.; Agababov, V. S.; Il'ina, I. P.; Rozhnatovskii, V. D.; Burmakina, A. V.
2016-06-01
One of the possible and, under certain conditions, sufficiently effective methods for reducing consumption of fuel and energy resources is the development of plants for combined generation of different kinds of energy. In the power industry of Russia, the facilities have become widespread in which the cogeneration technology, i.e., simultaneous generation of electric energy and heat, is implemented. Such facilities can use different plants, viz., gas- and steam-turbine plants and gas-reciprocating units. Cogeneration power supply can be further developed by simultaneously supplying the users not only with electricity and heat but also with cold. Such a technology is referred to as trigeneration. To produce electricity and heat, trigeneration plants can use the same facilities that are used in cogeneration, namely, gas-turbine plants, steam-turbine plants, and gas-reciprocating units. Cold can be produced in trigeneration plants using thermotransformers of various kinds, such as vaporcompression thermotransformers, air thermotransformers, and absorption thermotransformers, that operate as chilling machines. The thermotransformers can also be used in the trigeneration plants to generate heat. The main advantage of trigeneration plants based on gas-turbine plants or gas-reciprocating units over cogeneration plants is the increased thermodynamic power supply efficiency owing to utilization of the waste-gas heat not only in winter but also in summer. In the steam-turbine-based trigeneration plants equipped with absorption thermotransformers, the enhancement of the thermodynamic power supply efficiency is determined by the increase in the heat extraction load during the nonheating season. The article presents calculated results that demonstrate higher thermodynamic efficiency of a gas-turbine-based plant with an absorption thermotransformer that operates in the trigeneration mode compared with a cogeneration gas-turbine plant. The structural arrangements of trigeneration plants designed to supply electricity, heat, and cold to the users are shown and the principles of their operation are described. The article presents results of qualitative analysis of different engineering solutions applied to select one combination of power- and heat-generating equipment and thermotransformers or another.
Petropower energia project under way in Chile promises refiner better economics at lower cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-31
Construction of the Republic of Chile`s first public/private industrial partnership project is well under way. Ground was broken for the $232-million Petropower Energia Limitada project early this year, shortly after the final contract between the parties - Foster Wheeler Power Systems, Inc. (FWPS); Petrox S.A. Refineria de Petroleo and Empresa Nacional del Petroleo (ENAP) - was signed. The Petropower project, located adjacent to Petrox`s 84,000-b/d refinery in Talcahuano, represents the first project ever to combine petroleum coking technology with cogeneration technology in a single project financing. Petropower is 85% owned by FWPS, 7.5% by ENAP, the Chilean national oil companymore » and parent of Petrox S.A. When completed in mid-1998, the Petropower project will enable Petrox to refine heavier crudes and enhance the refinery`s flexibility and economics. The project will consist of a delayed coking facility (a 12,000-b/d delayed coking unit and a 7,000-b/d hydrotreating plant) and a 67-MW (59 MW net) cogeneration plant. The coke produced will fuel a Foster Wheeler proprietary-design circulating fluidized-bed (CFB) boiler which will generate all the high-pressure steam and electric power needs of the Petrox refinery. This unit will be the first circulating fluidized-bed boiler to be built in Latin America. The cogeneration facility, using limestone as a reagent and equipped with a baghouse, will control SO{sub x} emissions from combustion of the green coke fuel and easily meet all Chilean environmental standards. Moreover, by constructing the cogeneration facility, Petrox will not have to proceed with capital improvements to existing facilities to ensure a reliable source of steam and electricity, resulting in substantial savings for Petrox. The cogeneration plant provides a permanent {open_quotes}disposal{close_quotes} for all coke produced by the delayed coker, thereby solving any future problems of unwanted or excess coke.« less
Power generation using sugar cane bagasse: A heat recovery analysis
NASA Astrophysics Data System (ADS)
Seguro, Jean Vittorio
The sugar industry is facing the need to improve its performance by increasing efficiency and developing profitable by-products. An important possibility is the production of electrical power for sale. Co-generation has been practiced in the sugar industry for a long time in a very inefficient way with the main purpose of getting rid of the bagasse. The goal of this research was to develop a software tool that could be used to improve the way that bagasse is used to generate power. Special focus was given to the heat recovery components of the co-generation plant (economizer, air pre-heater and bagasse dryer) to determine if one, or a combination, of them led to a more efficient co-generation cycle. An extensive review of the state of the art of power generation in the sugar industry was conducted and is summarized in this dissertation. Based on this models were developed. After testing the models and comparing the results with the data collected from the literature, a software application that integrated all these models was developed to simulate the complete co-generation plant. Seven different cycles, three different pressures, and sixty-eight distributions of the flue gas through the heat recovery components can be simulated. The software includes an economic analysis tool that can help the designer determine the economic feasibility of different options. Results from running the simulation are presented that demonstrate its effectiveness in evaluating and comparing the different heat recovery components and power generation cycles. These results indicate that the economizer is the most beneficial option for heat recovery and that the use of waste heat in a bagasse dryer is the least desirable option. Quantitative comparisons of several possible cycle options with the widely-used traditional back-pressure turbine cycle are given. These indicate that a double extraction condensing cycle is best for co-generation purposes. Power generation gains between 40 and 100% are predicted for some cycles with the addition of optimum heat recovery systems.
The potential for industrial cogeneration development by 1990
NASA Astrophysics Data System (ADS)
1981-07-01
The cogeneration study focused on five industries that constitute three quarters of industrial steam demand: pulp and paper, chemicals, petroleum refining, steel, and food processing. These industries use almost one fifth of the total energy consumed in the United States. The analysis reflected the investment and regulatory concerns in the United States. The analysis reflected the investment used by industrial and utility managers. Phone discussions were held with approximately 70 companies to verify and augment the process and energy use data for the five industries.
Regional hospital improves efficiency with co-generation retrofit.
Knutson, D; Anderson, L
1999-11-01
Feasibility analysis of the co-generation retrofit of the Red Deer Regional Hospital pointed to a reasonable payback of capital cost and increased efficiency in operation of the facility. Budget restrictions nearly stopped the project from proceeding. Innovative construction procedures proposed by the Facility Management Group, in particular, Mr Keith Metcalfe, Director of Maintenance, allowed a worthwhile project to reach successful completion. We feel that this model can perhaps be used by similar facilities in the future to achieve their energy efficiency goals.
NASA Astrophysics Data System (ADS)
Khomenok, L. A.
2007-09-01
Problems related to efficient afterburning of fuel in the medium of gas-turbine unit exhaust gases, as well as new design arrangements of gas-jet burners used in the chambers for afterburning fuel in heat-recovery boilers at cogeneration stations equipped with combined-cycle plants, are considered. Results obtained from comparative experimental investigations of different gas-jet flame stabilizers at a test facility are presented, and the advantages of jet-ejector stabilizers are demonstrated.
NASA Astrophysics Data System (ADS)
Huzvar, Jozef; Kapjor, Andrej
2011-06-01
This article deals with combined production of heat and electricity for small premises, such as households, where energy consumption is around few kilowatts. This proposal of micro co-generation unit uses as a heat source an automatic burner for combustion of wood pellets. Construction of an equipment for the heat transport can be designed using different basic ways of heat transfer. Electricity is produced by the two-stroke steam engine and the generator.
Puerto Rico`s EcoElectrica LNG/power project marks a project financing first
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lammers, R.; Taylor, S.
1998-02-23
On Dec. 15, 1997, Enron International and Kenetech Energy Services achieved financial close on the $670 million EcoElectrica liquefied natural gas terminal and cogeneration project proposed for Puerto Rico. The project involves construction of a liquefied natural gas terminal, cogeneration plant, and desalination unit on the southern coast of Puerto Rico, in the Penuelas/Guayanilla area. EcoElectrica will include a 500-mw, combined-cycle cogeneration power plant fueled mainly by LNG imported from the 400 MMcfd Atlantic LNG project on the island of Trinidad. Achieving financial close on a project of this size is always a time-consuming matter and one with a numbermore » of challenges. These challenges were increased by the unique nature of both the project and its financing--no project financing had ever before been completed that combined an LNG terminal and power plant. The paper discusses the project, financing details and challenges, key investment considerations, and integrated project prospects.« less
Combined-cycle plant built in record time
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
This article reports that this low-cost cogeneration plant meets residential community`s environmental concerns with noise minimization, emissions control, and zero wastewater discharge. Supplying electricity to the local utility and steam to two hosts, the Auburndale cogeneration facility embodies the ``reference plant`` design approach developed by Westinghouse Power Generation (WPG), Orlando, Fla. With this approach customers meet their particular needs by choosing from a standard package of plant equipment and design options. Main goals of the concept are reduced construction time efficient and reliable power generation, minimal operating staff, and low cost. WPG built the plant on a turnkey basis formore » Auburndale Power Partners Limited Partnership (APP). APP is a partially owned subsidiary of Mission Energy, a California-based international developer and operator of independent-power facilities. The cogeneration facility supplies 150 MW of electric power to Florida Power Corp and exports 120,000 lb/hr of steam to Florida Distillers Co and Coca-Cola Foods.« less
Bravo, L; Ferrer, I
2011-01-01
Life Cycle Assessment was used to evaluate environmental impacts associated to a full-scale wastewater treatment plant (WWTP) in Barcelona Metropolitan Area, with a treatment capacity of 2 million population equivalent, focussing on energy aspects and resources consumption. The wastewater line includes conventional pre-treatment, primary settler, activated sludge with nitrogen removal, and tertiary treatment; and the sludge line consists of thickening, anaerobic digestion, cogeneration, dewatering and thermal drying. Real site data were preferably included in the inventory. Environmental impacts of the resulting impact categories were determined by the CLM 2 baseline method. According to the results, the combustion of natural gas in the cogeneration engine is responsible for the main impact on Climate Change and Depletion of Abiotic Resources, while the combustion of biogas in the cogeneration unit accounts for a minor part. The results suggest that the environmental performance of the WWTP would be enhanced by increasing biogas production through improved anaerobic digestion of sewage sludge.
Microturbine and Thermoelectric Generator Combined System: A Case Study.
Miozzo, Alvise; Boldrini, Stefano; Ferrario, Alberto; Fabrizio, Monica
2017-03-01
Waste heat recovery is one of the suitable industrial applications of thermoelectrics. Thermoelectric generators (TEG) are used, commonly, only for low-mid size power generation systems. The low efficiency of thermoelectric modules generally does not encourage their combination with high power and temperature sources, such as gas turbines. Nevertheless, the particular features of thermoelectric technology (no moving parts, scalability, reliability, low maintenance costs) are attractive for many applications. In this work, the feasibility of the integration of a TE generator into a cogeneration system is evaluated. The cogeneration system consists of a microturbine and heat exchangers for the production of electrical and thermal energy. The aim is to improve electric power generation by using TE modules and the “free” thermal energy supplied by the cogeneration system, through the exhaust pipe of the microturbine. Three different solutions for waste heat recovery from the exhausts gas are evaluated, from the fluid dynamics and heat transfer point of view, to find out a suitable design strategy for a combined power generation system.
NASA Astrophysics Data System (ADS)
Delucia, M.; Bronconi, R.; Carnevale, E.
1994-04-01
Gas turbine air cooling systems serve to raise performance to peak power levels during the hot months when high atmospheric temperatures cause reductions in net power output. This work describes the technical and economic advantages of providing a compressor inlet air cooling system to increase the gas turbine's power rating and reduce its heat rate. The pros and cons of state-of-the-art cooling technologies, i.e., absorption and compression refrigeration, with and without thermal energy storage, were examined in order to select the most suitable cooling solution. Heavy-duty gas turbine cogeneration systems with and without absorption units were modeled, as well as various industrial sectors, i.e., paper and pulp, pharmaceuticals, food processing, textiles, tanning, and building materials. The ambient temperature variations were modeled so the effects of climate could be accounted for in the simulation. The results validated the advantages of gas turbine cogeneration with absorption air cooling as compared to other systems without air cooling.
NASA Astrophysics Data System (ADS)
Shahzad, Muhammad Wakil; Ng, Kim Choon; Thu, Kyaw
2016-06-01
Power and desalination cogeneration plants are common in many water scared courtiers. Designers and planners for cogeneration face tough challenges in deciding the options:- Is it better to operate a power plant (PP) with the reverse osmosis (i.e., PP+RO) or the thermally-driven multi-effect distillation/multi-stage flashed (PP+MED/MSF) methods. From literature, the RO methods are known to be energy efficient whilst the MED/MSF are known to have excellent thermodynamic synergies as only low pressure and temperature steam are used. Not with-standing the challenges of severe feed seawater of the Gulf, such as the frequent harmful algae blooms (HABs) and high silt contents, this presentation presents a quantitative analyses using the exergy and energetic approaches in evaluating the performances of a real cogeneration plant that was recently proposed in the eastern part of Saudi Arabia. We demonstrate that the process choice of PP+RO versus PP+MED depends on the inherent efficiencies of individual process method which is closely related to innovative process design. In this connection, a method of primary fuel cost apportionment for a co-generation plant with a MED desalination is presented. We show that an energy approach, that captures the quality of expanding steam, is a better method over the conventional work output (energetic) and the energy method seems to be over-penalizing a thermally-driven MED by as much as 22% in the operating cost of water.
Evaluation of the environmental sustainability of different waste-to-energy plant configurations.
Lombardi, Lidia; Carnevale, Ennio A
2018-03-01
Residual municipal solid waste (MSW) has an average lower heating value higher than 10GJ/Mg in the EU, and can be recovered in modern Waste-to-Energy (WtE) plants, producing combined heat and power (CHP) and reaching high levels of energy recovery. CHP is pinpointed as the best technique for energy recovery from waste. However, in some cases, heat recovery is not technically feasible - due to the absence of a thermal user (industrial plant or district heating) in the vicinity of the WtE plant - and power production remains the sole possibility. In these cases, there are some challenges involved in increasing the energy performance as much as possible. High energy recovery efficiency values are very important for the environmental sustainability of WtE plants. The more electricity and heat is produced, the better the saving of natural resources that can be achieved. Within this frame, the aim of this work is to carry out an environmental assessment, through Life Cycle Assessment, of an MSW WtE plant, considering different sizes and operated in different ways, from power production only to full cogeneration. The main assumption is that the electric conversion efficiency increases as the plant size increases, introducing technical improvements thanks to the economies of scale. Impact assessment results were calculated using ReCiPe 2008 methods. The climate change indicator is positive when the WtE plant is operated in power production only mode, with values decreasing for the increasing size. Values for the climate change are negative when cogeneration is applied, requiring increasing cogeneration ratios for decreasing size. Similarly, the fossil fuel depletion indicator benefits from increase of both the plant size and the cogeneration rate, but it is always negative, meaning that the residual MSW burning with energy recovery always provides a saving of fossil primary energy. Other indicator values are in general negative and are also beneficially affected by increasing the plant size, but they worsen when increasing the cogeneration rate. The remaining indicators - i.e. human toxicity and terrestrial ecotoxicity - always have positive values, which decrease for increasing plant size and increase as the cogeneration rate increases. However, the local context should be evaluated carefully with reference to the type of electricity which is substituted and in view of a future massive production of renewable electricity, because conclusions change accordingly. Finally, it was evaluated that the inclusion of bottom ash recovery - instead of landfilling - can significantly improve the values of several impact assessment indicators. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kone, Diakalia
The present study aimed at assessing the environmental benefits of power management practices based on cogeneration in the particular industrial sector of hospitals and healthcare. Cogeneration power systems, also known as "Combined Heat and Power" (CHP) or Cogen, supply on-site electricity and heat from a single fuel source (natural gas in general). While the efficiency of conventional plants to produce power and heat separately is limited to about 30%, the efficiency of a CHP plant is close to 80% and can reach up to 90% in some applications (Borbely et Kreider, 2001). One of the distinctive features of hospitals is their continuous demand for both type of energy (electricity and heat), which makes them good candidate for cogeneration. However, in North America at the present time, less than 5% of hospitals run on CHP. Most are being supplied with electricity by conventional power plants, run by specialized companies, and use on-site boiler(s) to generate heat. Energy spending can reach up to 3% of an hospital's annual operational budget. There are also environmental impacts related to current energy supply and use in hospitals. For instance, the burning of fossil fuels releases greenhouse gases (GHG), which contribute to human health problems and climate change. The first objective of the study was to outline the main benefits and challenges faced by hospitals that aim at becoming their own energy co-generator, in comparison to having power and heat produced separately. Our second objective was to assess prospectively (proactively) the environmental impacts of a cogeneration plant that is being planned, but not yet operated, in a Canadian hospital. The methodology was based on literature reviews and on a case study, namely that of The Moncton Hospital (TMH)/L'Hopital de Moncton, Moncton, New Brunswick, Canada. This hospital is considered a large hospital with 375 beds and a major and expanding ambulatory care service. It is also in the process of developing a 1.06 MW cogeneration plant, to be run on natural gas, to meet about 30% of the facility's current demand for electricity and heat. In order to anticipate the environmental consequences of this CHP project, an environmental impact assessment (EIA) was conducted, according to the principles that apply in New Brunswick (Regulation 87-83 on EIA). A literature review was conducted and a matrix approach (matrix of impacts) was used to identify and assess the anticipated environmental impacts. The study showed that multiple stakeholders in the healthcare sector can reap benefits of CHP deployment. Facility owners can reduce energy costs and increase power reliability to enhance operations' continuity, during normal and extraordinary times (e.g., natural disasters). For instance, when hurricanes Katrina and Rita struck the United States in 2005, hospitals running with CHP were able to provide secure electricity supplies for emergency facilities and shelters. CHP also has environmental benefits related to its distinctively high efficiency. But its deployment in the healthcare sector also provides challenges, mainly due to the fact that power production is not a core activity for an hospital. These challenges can be overcome, however, as shown by numerous success stories in hospitals worldwide; specialised resources are available to help hospitals switch to CHP. This study underlines some of the steps a hospital can take toward this aim. EIA of The Moncton Hospital CHP project suggests that, globally, the environmental impacts of CHP are reduced compared to the traditional production of electricity and heat separately. Cogeneration utilizes fewer resources (fuel) and therefore releases fewer GHG and other pollutants. However, quantifying the emissions avoided is challenging. Also, the environmental benefits of CHP may be less obvious when compared to a centralised nuclear or hydraulic power production, which emits less GHG than power plants operating on coal or fuel oil. The study also indicates that other conditions are required to increase the environmental gains that can be expected from CHP deployment in the hospital sector. These conditions include the use of renewable fuel sources (biomass), the development of well-structured frameworks (e.g., efficient environmental management systems) to coordinate and leverage environmental stewardship initiatives within hospitals, and the development of energy partnerships (e.g., municipal heat networks). A broad, eco-systemic vision, like the one of industrial ecology, would help strengthen the ecological benefits of cogeneration in the hospital and health care sector. Key Words Heat and power cogeneration, hospitals, benefits/challenges, environment, society, environmental impact assessment, Canada, sustainable development, industrial ecology.
Benefits of advanced technology in industrial cogeneration
NASA Technical Reports Server (NTRS)
Barna, G. J.; Burns, R. K.
1979-01-01
This broad study is aimed at identifying the most attractive advanced energy conversion systems for industrial cogeneration for the 1985 to 2000 time period and assessing the advantages of advanced technology systems compared to using today's commercially available technology. Energy conversion systems being studied include those using steam turbines, open cycle gas turbines, combined cycles, diesel engines, Stirling engines, closed cycle gas turbines, phosphoric acid and molten carbonate fuel cells and thermionics. Specific cases using today's commercially available technology are being included to serve as a baseline for assessing the advantages of advanced technology.
Pressurized fluidized bed offers promising route to cogeneration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-03-01
STAL-LAVAL has been monitoring the development of pressurized fluidized-bed combustion (PFBC) technology and has decided to apply it as a way to burn coal and satisfy the important criteria of efficiency, low cost, environmental acceptability, low investment cost, and the capacity to use a wide range of coal qualities. The present status of PFBC and co-generation technology is reviewed and examples of industrial as well as utiltiy applications are cited. A successful commercialization of PFBC could contribute to the success of coal-utilization policies. (DCK)
NASA Technical Reports Server (NTRS)
Meyer, C. F.
1980-01-01
The technical and economic feasibility of incorporating thermal energy storage components into the proposed Twin Cities District heating project was evaluated. The technical status of the project is reviewed and conceptual designs of district heating systems with and without thermal energy storage were compared in terms of estimated capital requirements, fuel consumption, delivered energy cost, and environmental aspects. The thermal energy storage system is based on cogeneration and the storage of heat in aquifers.
Sustainable Water and Energy in Gaza Strip
NASA Astrophysics Data System (ADS)
Hamdan, L.; Zarei, M.; Chianelli, R.; Gardner, E.
2007-12-01
Shortage of fresh water is a common problem in different areas of the world including the Middle East. Desalination of seawater and brackish water is the cheapest way to obtain fresh water in many regions. This research focuses on the situation in Gaza Strip where there is a severe shortage in the energy and water supply. The depletion of fresh water supplies and lack of wastewater treatments result in environmental problems. A solar powered cogeneration plant producing water and energy is proposed to be a suitable solution for Gaza Strip. Solar energy, using Concentrating Solar thermal Power (CSP) technologies, is used to produce electricity by a steam cycle power plant. Then the steam is directed to a desalination plant where it is used to heat the seawater to obtain freshwater. The main objective of this research is to outline a solution for the water problems in Gaza Strip, which includes a cogeneration (power and water) solar powered plant. The research includes four specific objectives: 1- an environmental and economic comparison between solar and fossil fuel energies; 2- technical details for the cogeneration plant; 3- cost and funding, 4- the benefits.
Analysis of greenhouse gas emissions from 10 biogas plants within the agricultural sector.
Liebetrau, J; Reinelt, T; Clemens, J; Hafermann, C; Friehe, J; Weiland, P
2013-01-01
With the increasing number of biogas plants in Germany the necessity for an exact determination of the actual effect on the greenhouse gas emissions related to the energy production gains importance. Hitherto the life cycle assessments have been based on estimations of emissions of biogas plants. The lack of actual emission evaluations has been addressed within a project from which the selected results are presented here. The data presented here have been obtained during a survey in which 10 biogas plants were analysed within two measurement periods each. As the major methane emission sources the open storage of digestates ranging from 0.22 to 11.2% of the methane utilized and the exhaust of the co-generation units ranging from 0.40 to 3.28% have been identified. Relevant ammonia emissions have been detected from the open digestate storage. The main source of nitrous oxide emissions was the co-generation unit. Regarding the potential of measures to reduce emissions it is highly recommended to focus on the digestate storage and the exhaust of the co-generation.
Cogeneration Technology Alternatives Study (CTAS). Volume 5: Cogeneration systems results
NASA Technical Reports Server (NTRS)
Gerlaugh, H. E.; Hall, E. W.; Brown, D. H.; Priestley, R. R.; Knightly, W. F.
1980-01-01
The use of various advanced energy conversion systems is examined and compared with each other and with current technology systems for savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. The methodology and results of matching the cogeneration energy conversion systems to approximately 50 industrial processes are described. Results include fuel energy saved, levelized annual energy cost saved, return on investment, and operational factors relative to the noncogeneration base cases.
Waste-to-Energy Cogeneration Project, Centennial Park
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Clay; Mandon, Jim; DeGiulio, Thomas
The Waste-to-Energy Cogeneration Project at Centennial Park has allowed methane from the closed Centennial landfill to export excess power into the the local utility’s electric grid for resale. This project is part of a greater brownfield reclamation project to the benefit of the residents of Munster and the general public. Installation of a gas-to-electric generator and waste-heat conversion unit take methane byproduct and convert it into electricity at the rate of about 103,500 Mwh/year for resale to the local utility. The sale of the electricity will be used to reduce operating budgets by covering the expenses for streetlights and utilitymore » bills. The benefits of such a project are not simply financial. Munster’s Waste-to Energy Cogeneration Project at Centennial Park will reduce the community’s carbon footprint in an amount equivalent to removing 1,100 cars from our roads, conserving enough electricity to power 720 homes, planting 1,200 acres of trees, or recycling 2,000 tons of waste instead of sending it to a landfill.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenda, W.; Shrivastava, V.K.
A Definitional Mission team evaluated the prospects of the US Trade and Development Program (TDP) funding a feasibility study that would assist the Government of Kenya in developing power cogeneration plants in three Kenyan sugar factories and possibly two more that are now in the planning stage or construction. The major Kenyan sugar producing region around Kisumu, on Lake Victoria has climatic conditions that permit cane growing operations ideally suitable for cogeneration of power in sugar factories. The total potentially available capacity from the proposed rehabilitation of the three mills will be approximately 25.15 MW, or 5.7 percent of totalmore » electricity production.« less
Borax spends $30M for cogeneration system. [US Borax and Chemical Corp
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barber, J.
1982-09-20
A $30 million natural-gas-fired turbine power plant will provide all the electricity and steam needed at the US Borax and Chemical Corp. plant in Los Angeles. The cogeneration facility will come on line in 1984, and will pay for itself in about five years. The plant will use only half the 46 megawatts produced, the 22 megawatt surplus being sold to Southern California Edison Co. on a 20-year contract at a price pegged to the utility's avoided costs. Natural gas consumption at the plant will remain about the same. (DCK)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gleason, T.C.J.
1992-06-01
The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.
Cogeneration Technology Alternatives Study (CTAS). Volume 2: Analytical approach
NASA Technical Reports Server (NTRS)
Gerlaugh, H. E.; Hall, E. W.; Brown, D. H.; Priestley, R. R.; Knightly, W. F.
1980-01-01
The use of various advanced energy conversion systems were compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. The ground rules established by NASA and assumptions made by the General Electric Company in performing this cogeneration technology alternatives study are presented. The analytical methodology employed is described in detail and is illustrated with numerical examples together with a description of the computer program used in calculating over 7000 energy conversion system-industrial process applications. For Vol. 1, see 80N24797.
Dwivedi, Puneet; Khanna, Madhu
2014-01-01
Woody feedstocks will play a critical role in meeting the demand for biomass-based energy products in the US. We developed an integrated model using comparable system boundaries and common set of assumptions to ascertain unit cost and greenhouse gas (GHG) intensity of electricity and ethanol derived from slash pine (Pinus elliottii) at the production and consumption levels by considering existing automobile technologies. We also calculated abatement cost of greenhouse gas (GHG) emissions with respect to comparable energy products derived from fossil fuels. The production cost of electricity derived using wood chips was at least cheaper by 1 ¢ MJ−1 over electricity derived from wood pellets. The production cost of ethanol without any income from cogenerated electricity was costlier by about 0.7 ¢ MJ−1 than ethanol with income from cogenerated electricity. The production cost of electricity derived from wood chips was cheaper by at least 0.7 ¢ MJ−1 than the energy equivalent cost of ethanol produced in presence of cogenerated electricity. The cost of using ethanol as a fuel in a flex-fuel vehicle was at least higher by 6 ¢ km−1 than a comparable electric vehicle. The GHG intensity of per km distance traveled in a flex-fuel vehicle was greater or lower than an electric vehicle running on electricity derived from wood chips depending on presence and absence of GHG credits related with co-generated electricity. A carbon tax of at least $7 Mg CO2e−1 and $30 Mg CO2e−1 is needed to promote wood-based electricity and ethanol production in the US, respectively. The range of abatement cost of GHG emissions is significantly dependent on the harvest age and selected baseline especially for electricity generation. PMID:24937461
Efficient Use of Cogeneration and Fuel Diversification
NASA Astrophysics Data System (ADS)
Kunickis, M.; Balodis, M.; Sarma, U.; Cers, A.; Linkevics, O.
2015-12-01
Energy policy of the European Community is implemented by setting various goals in directives and developing support mechanisms to achieve them. However, very often these policies and legislation come into contradiction with each other, for example Directive 2009/28/EC on the promotion of the use of energy from renewable sources and Directive 2012/27/EU on energy efficiency, repealing Directive 2004/8/EC on the promotion of cogeneration based on a useful heat demand. In this paper, the authors attempt to assess the potential conflicts between policy political objectives to increase the share of high-efficiency co-generation and renewable energy sources (RES), based on the example of Riga district heating system (DHS). If a new heat source using biomass is built on the right bank of Riga DHS to increase the share of RES, the society could overpay for additional heat production capacities, such as a decrease in the loading of existing generating units, thereby contributing to an inefficient use of existing capacity. As a result, the following negative consequences may arise: 1) a decrease in primary energy savings (PES) from high-efficiency cogeneration in Riga DHS, 2) an increase in greenhouse gas (GHG) emissions in the Baltic region, 3) the worsening security situation of electricity supply in the Latvian power system, 4) an increase in the electricity market price in the Lithuanian and Latvian price areas of Nord Pool power exchange. Within the framework of the research, calculations of PES and GHG emission volumes have been performed for the existing situation and for the situation with heat source, using biomass. The effect of construction of biomass heat source on power capacity balances and Nord Pool electricity prices has been evaluated.
Dwivedi, Puneet; Khanna, Madhu
2014-01-01
Woody feedstocks will play a critical role in meeting the demand for biomass-based energy products in the US. We developed an integrated model using comparable system boundaries and common set of assumptions to ascertain unit cost and greenhouse gas (GHG) intensity of electricity and ethanol derived from slash pine (Pinus elliottii) at the production and consumption levels by considering existing automobile technologies. We also calculated abatement cost of greenhouse gas (GHG) emissions with respect to comparable energy products derived from fossil fuels. The production cost of electricity derived using wood chips was at least cheaper by 1 ¢ MJ-1 over electricity derived from wood pellets. The production cost of ethanol without any income from cogenerated electricity was costlier by about 0.7 ¢ MJ-1 than ethanol with income from cogenerated electricity. The production cost of electricity derived from wood chips was cheaper by at least 0.7 ¢ MJ-1 than the energy equivalent cost of ethanol produced in presence of cogenerated electricity. The cost of using ethanol as a fuel in a flex-fuel vehicle was at least higher by 6 ¢ km-1 than a comparable electric vehicle. The GHG intensity of per km distance traveled in a flex-fuel vehicle was greater or lower than an electric vehicle running on electricity derived from wood chips depending on presence and absence of GHG credits related with co-generated electricity. A carbon tax of at least $7 Mg CO2e-1 and $30 Mg CO2e-1 is needed to promote wood-based electricity and ethanol production in the US, respectively. The range of abatement cost of GHG emissions is significantly dependent on the harvest age and selected baseline especially for electricity generation.
Congeneration feasibility: Otis Elavator Company and Polychrome Corporation
NASA Astrophysics Data System (ADS)
Fox, H.
1982-05-01
An investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY is discussed. Existing electrical and steam producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return on investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, this detailed study provides valuable insights.
Cogeneration technology alternatives study. Volume 6: Computer data
NASA Technical Reports Server (NTRS)
1980-01-01
The potential technical capabilities of energy conversion systems in the 1985 - 2000 time period were defined with emphasis on systems using coal, coal-derived fuels or alternate fuels. Industrial process data developed for the large energy consuming industries serve as a framework for the cogeneration applications. Ground rules for the study were established and other necessary equipment (balance-of-plant) was defined. This combination of technical information, energy conversion system data ground rules, industrial process information and balance-of-plant characteristics was analyzed to evaluate energy consumption, capital and operating costs and emissions. Data in the form of computer printouts developed for 3000 energy conversion system-industrial process combinations are presented.
The T-100-12.8 family of cogeneration steam turbines: Yesterday, today, and tomorrow
NASA Astrophysics Data System (ADS)
Valamin, A. E.; Kultyshev, A. Yu.; Shibaev, T. L.; Sakhnin, Yu. A.; Stepanov, M. Yu.
2013-08-01
The T-100-12.8 turbine and its versions, a type of cogeneration steam turbines that is among best known, unique, and most widely used ones in Russia and abroad, are considered. A list of turbine design versions and quantities in which they were produced, their technical and economic indicators, design features, schematic solutions used in different design versions, and a list of solutions available in a comprehensive portfolio offered for modernizing type T-100-12.8 turbines are presented. Information about amounts in which turbines of the last version are supplied currently and supposed to be supplied soon is given.
Bronx Zoo cogeneration project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivet, P.H.
The New York Zoological Society commenced feasibility studies for a proposed cogeneration and district heating system for the Bronz Zoo in spring 1982. Early studies focused on evaluating the Zoo's energy loads, infrastructure, and energy delivery and financing systems. The Zoological Society and New York City joined in the decision to support the construction of a system which would serve not only the Bronx Zoo but also five nearby City-funded installations, including the adjacent New York Botanical Garden. Since the submission of that study, the project has been modified in scope, scaling back to a generating capacity designed to servemore » only the Bronz Zoo.« less
CELCAP: A Computer Model for Cogeneration System Analysis
NASA Technical Reports Server (NTRS)
1985-01-01
A description of the CELCAP cogeneration analysis program is presented. A detailed description of the methodology used by the Naval Civil Engineering Laboratory in developing the CELCAP code and the procedures for analyzing cogeneration systems for a given user are given. The four engines modeled in CELCAP are: gas turbine with exhaust heat boiler, diesel engine with waste heat boiler, single automatic-extraction steam turbine, and back-pressure steam turbine. Both the design point and part-load performances are taken into account in the engine models. The load model describes how the hourly electric and steam demand of the user is represented by 24 hourly profiles. The economic model describes how the annual and life-cycle operating costs that include the costs of fuel, purchased electricity, and operation and maintenance of engines and boilers are calculated. The CELCAP code structure and principal functions of the code are described to how the various components of the code are related to each other. Three examples of the application of the CELCAP code are given to illustrate the versatility of the code. The examples shown represent cases of system selection, system modification, and system optimization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanvick, T.W.
The Logan Generating Plant (formerly Keystone Cogeneration Project) is a 230 MW (gross) pulverized coal cogeneration facility located on the Delaware River in Logan Township, New Jersey, off Route 130. Owned and operated by U.S. Generating Company, the plant was built by Bechtel Corporation, which provided engineering, procurement, construction, and startup services. Power from the plant is furnished to Atlantic Electric, and approximately 50,000 pounds of process steam per hour is provided to Monsanto`s adjacent facility. U.S. Generating Company is committed to operating plants with close attention to the environment and has developed a specific Environmental Mission Statement. This papermore » addresses some of the key environmental features at the Logan Generating Plant.« less
Assessment of steam-injected gas turbine systems and their potential application
NASA Technical Reports Server (NTRS)
Stochl, R. J.
1982-01-01
Results were arrived at by utilizing and expanding on information presented in the literature. The results were analyzed and compared with those for simple gas turbine and combined cycles for both utility power generation and industrial cogeneration applications. The efficiency and specific power of simple gas turbine cycles can be increased as much as 30 and 50 percent, respectively, by the injection of steam into the combustor. Steam-injected gas turbines appear to be economically competitive with both simple gas turbine and combined cycles for small, clean-fuel-fired utility power generation and industrial cogeneration applications. For large powerplants with integrated coal gasifiers, the economic advantages appear to be marginal.
Coal gasifier cogeneration powerplant project
NASA Technical Reports Server (NTRS)
Shure, L. I.; Bloomfield, H. S.
1980-01-01
Industrial cogeneration and utility pr systems were analyzed and a conceptual design study was conducted to evaluate the economic feasibility of a coal gasifier power plant for NASA Lewis Research Center. Site location, plant size, and electric power demand were considered in criteria developed for screening and selecting candidates that could use a wide variety of coals, including that from Ohio. A fluidized bed gasifier concept was chosen as the baseline design and key components of the powerplant were technically assessed. No barriers to environmental acceptability are foreseen. If funded, the powerplant will not only meet the needs of the research center, but will reduce the commercial risk for utilities and industries by fully verifying and demonstrating the technology, thus accelerating commercialization.
Simulation of diurnal thermal energy storage systems: Preliminary results
NASA Astrophysics Data System (ADS)
Katipamula, S.; Somasundaram, S.; Williams, H. R.
1994-12-01
This report describes the results of a simulation of thermal energy storage (TES) integrated with a simple-cycle gas turbine cogeneration system. Integrating TES with cogeneration can serve the electrical and thermal loads independently while firing all fuel in the gas turbine. The detailed engineering and economic feasibility of diurnal TES systems integrated with cogeneration systems has been described in two previous PNL reports. The objective of this study was to lay the ground work for optimization of the TES system designs using a simulation tool called TRNSYS (TRaNsient SYstem Simulation). TRNSYS is a transient simulation program with a sequential-modular structure developed at the Solar Energy Laboratory, University of Wisconsin-Madison. The two TES systems selected for the base-case simulations were: (1) a one-tank storage model to represent the oil/rock TES system; and (2) a two-tank storage model to represent the molten nitrate salt TES system. Results of the study clearly indicate that an engineering optimization of the TES system using TRNSYS is possible. The one-tank stratified oil/rock storage model described here is a good starting point for parametric studies of a TES system. Further developments to the TRNSYS library of available models (economizer, evaporator, gas turbine, etc.) are recommended so that the phase-change processes is accurately treated.
Cogeneration technology alternatives study. Volume 1: Summary report
NASA Technical Reports Server (NTRS)
1980-01-01
Data and information in the area of advanced energy conversion systems for industrial congeneration applications in the 1985-2000 time period was studied. Six current and thirty-one advanced energy conversion systems were defined and combined with appropriate balance-of-plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a framework for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. Various cogeneration strategies were analyzed and both topping and bottoming (using industrial by-product heat) applications were included. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Typically fuel energy savings of 10 to 25 percent were predicted compared to traditional on-site furnaces and utility electricity. With the variety of industrial requirements, each advanced technology had attractive applications. Overall, fuel cells indicated the greatest fuel energy savings and emission reductions. Gas turbines and combined cycles indicated high overall annual cost savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal-derived fuels, or coal with advanced fluid bed combustion or on-site gasification systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Purpose of this study is to examine the results of FERG and state efforts to encourage the development of cogeneration and small power production under Title II of the Public Utility Regualtory Policies Act of 1978 (PURPA) in the years since the statute was enacted. The frame of reference specified by DOE for use in this study includes both the original purposes of the legislation as set forth in PURPA and the current overall energy policy goal which is to ''foster an adequate supply of energy at reasonable costs.'' This review of PURPA implementation efforts is designed to assess themore » results to date in terms of achieving the stated goals of the statute (including ''to encourage cogeneration and small power production''), identify perceived areas of conflict between federal and state efforts to maximize development of qualifying facilities (QFs) and current Administration concerns for achieving greater levels of economic efficiency in electric power supply, briefly examine the nature of such conflicts, with reference to specific cases wherever possible, and suggest possible means of conforming government efforts to encourage QF development with the economic efficiency objectives underlying national energy policy.« less
High-power microwave production by gyroharmonic conversion and co-generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaPointe, M.A.; Yoder, R.B.; Wang, M.
1997-03-01
An rf accelerator that adds significant gyration energy to a relativistic electron beam, and mechanisms for extracting coherent radiation from the beam, are described. The accelerator is a cyclotron autoresonance accelerator (CARA), underlying theory and experimental tests of which are reviewed. The measurements illustrate the utility of CARA in preparing beams for high harmonic gyro interactions. Examples of preparation of gyrating axis-encircling beams of {approximately}400kV, 25 A with 1{lt}a{lt}2 using a 2.856 GHz CARA are discussed. Generation of MW-level harmonic power emanating from a beam prepared in CARA into an output cavity structure is predicted by theory. First measurements ofmore » intense superradiant 2nd through 6th harmonic emission from a CARA beam are described. Gyroharmonic conversion (GHC) at MW power levels into an appropriate resonator can be anticipated, in view of the results described here. Another radiation mechanism, closely related to GHC, is also described. This mechanism, dubbed {open_quotes}co-generation,{close_quotes} is based on the fact that the lowest TE{sub sm} mode in a cylindrical waveguide at frequency sw with group velocity nearly identical to group velocity for the TE{sub 11} mode at frequency w is that with s=7, m=2. This allows coherent radiation to be generated at the 7th harmonic co-existent with CARA and in the self-same rf structure. Conditions are found where co-generation of 7th harmonic power at 20 GHz is possible with overall efficiency greater than 80{percent}. It is shown that operation of a cw co-generator can take place without need of a power supply for the gun. Efficiency for a multi-MW 20 GHz co-generator is predicted to be high enough to compete with other sources, even after taking into account the finite efficiency of the rf driver required for CARA. {copyright} {ital 1997 American Institute of Physics.}« less
Lombardi, Lidia; Mendecka, Barbara; Carnevale, Ennio
2018-06-15
The separate collection of Used Cooking Oil (UCO) is gaining popularity through several countries in Europe. An appropriate management of UCO waste stream leads to substantial benefits. In this study, we analyse two different possibilities of UCO energy reuse: the direct feed to a reciprocating internal combustion engine (ICE) for cogeneration purpose, and the processing to generate biodiesel. Concerning biodiesel production, we analyse four among conventional and innovative technologies, characterised by different type and amount of used chemicals, heat and electricity consumptions and yields. We perform a systematic evaluation of environmental benefits and drawbacks by applying life cycle assessment (LCA) analysis to compare the alternatives. For the impact assessment, two methods are selected: the Global Warming Potential (GWP) and Cumulative Exergy Consumption (CExC). Results related only to the processing phases (i.e. not including yet the avoided effects) show that the recovery of UCO in cogeneration plant has in general lower values in terms of environmental impacts than its employment in biodiesel production. When products and co-products substitution are included, the savings obtained by the substitution of conventional diesel production, in the biodiesel cases, are significantly higher than the avoided effects for electricity and heat in the cogeneration case. In particular, by using the UCO in the biodiesel production processes, the savings vary from 41.6 to 54.6 GJ ex per tUCO, and from 2270 to 2860 kg CO 2eq per tUCO for CExC and GWP, respectively. A particular focus is put on sensitivity and uncertainty analyses. Overall, high uncertainty of final results for process impacts is observed, especially for the supercritical methanol process. Low uncertainty values are evaluated for the avoided effects. Including the uncertain character of the impacts, cogeneration scenario and NaOH catalysed process of biodiesel production result to be the most suitable solutions from the process impacts and avoided effects perspective. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of a thermal scheme for a cogeneration combined-cycle unit with an SVBR-100 reactor
NASA Astrophysics Data System (ADS)
Kasilov, V. F.; Dudolin, A. A.; Krasheninnikov, S. M.
2017-02-01
At present, the prospects for development of district heating that can increase the effectiveness of nuclear power stations (NPS), cut down their payback period, and improve protection of the environment against harmful emissions are being examined in the nuclear power industry of Russia. It is noted that the efficiency of nuclear cogeneration power stations (NCPS) is drastically affected by the expenses for heat networks and heat losses during transportation of a heat carrier through them, since NPSs are usually located far away from urban area boundaries as required for radiation safety of the population. The prospects for using cogeneration power units with small or medium power reactors at NPSs, including combined-cycle units and their performance indices, are described. The developed thermal scheme of a cogeneration combined-cycle unit (CCU) with an SBVR-100 nuclear reactor (NCCU) is presented. This NCCU should use a GE 6FA gasturbine unit (GTU) and a steam-turbine unit (STU) with a two-stage district heating plant. Saturated steam from the nuclear reactor is superheated in a heat-recovery steam generator (HRSG) to 560-580°C so that a separator-superheater can be excluded from the thermal cycle of the turbine unit. In addition, supplemental fuel firing in HRSG is examined. NCCU effectiveness indices are given as a function of the ambient air temperature. Results of calculations of the thermal cycle performance under condensing operating conditions indicate that the gross electric efficiency η el NCCU gr of = 48% and N el NCCU gr = 345 MW can be achieved. This efficiency is at maximum for NCCU with an SVBR-100 reactor. The conclusion is made that the cost of NCCU installed kW should be estimated, and the issue associated with NCCUs siting with reference to urban area boundaries must be solved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tao, Greg, G.; Virkar, Anil, V.; Bandopadhyay, Sukumar
2009-06-30
Developing safe, reliable, cost-effective, and efficient hydrogen-electricity co-generation systems is an important step in the quest for national energy security and minimized reliance on foreign oil. This project aimed to, through materials research, develop a cost-effective advanced technology cogenerating hydrogen and electricity directly from distributed natural gas and/or coal-derived fuels. This advanced technology was built upon a novel hybrid module composed of solid-oxide fuel-assisted electrolysis cells (SOFECs) and solid-oxide fuel cells (SOFCs), both of which were in planar, anode-supported designs. A SOFEC is an electrochemical device, in which an oxidizable fuel and steam are fed to the anode and cathode,more » respectively. Steam on the cathode is split into oxygen ions that are transported through an oxygen ion-conducting electrolyte (i.e. YSZ) to oxidize the anode fuel. The dissociated hydrogen and residual steam are exhausted from the SOFEC cathode and then separated by condensation of the steam to produce pure hydrogen. The rationale was that in such an approach fuel provides a chemical potential replacing the external power conventionally used to drive electrolysis cells (i.e. solid oxide electrolysis cells). A SOFC is similar to the SOFEC by replacing cathode steam with air for power generation. To fulfill the cogeneration objective, a hybrid module comprising reversible SOFEC stacks and SOFC stacks was designed that planar SOFECs and SOFCs were manifolded in such a way that the anodes of both the SOFCs and the SOFECs were fed the same fuel, (i.e. natural gas or coal-derived fuel). Hydrogen was produced by SOFECs and electricity was generated by SOFCs within the same hybrid system. A stand-alone 5 kW system comprising three SOFEC-SOFC hybrid modules and three dedicated SOFC stacks, balance-of-plant components (including a tailgas-fired steam generator and tailgas-fired process heaters), and electronic controls was designed, though an overall integrated system assembly was not completed because of limited resources. An inexpensive metallic interconnects fabrication process was developed in-house. BOP components were fabricated and evaluated under the forecasted operating conditions. Proof-of-concept demonstration of cogenerating hydrogen and electricity was performed, and demonstrated SOFEC operational stability over 360 hours with no significant degradation. Cost analysis was performed for providing an economic assessment of the cost of hydrogen production using the targeted hybrid technology, and for guiding future research and development.« less
NASA Astrophysics Data System (ADS)
Siler-Evans, Kyle
There is growing interest in reducing the environmental and human-health impacts resulting from electricity generation. Renewable energy, energy efficiency, and energy conservation are all commonly suggested solutions. Such interventions may provide health and environmental benefits by displacing emissions from conventional power plants. However, the generation mix varies considerably from region to region and emissions vary by the type and age of a generator. Thus, the benefits of an intervention will depend on the specific generators that are displaced, which vary depending on the timing and location of the intervention. Marginal emissions factors (MEFs) give a consistent measure of the avoided emissions per megawatt-hour of displaced electricity, which can be used to evaluate the change in emissions resulting from a variety of interventions. This thesis presents the first systematic calculation of MEFs for the U.S. electricity system. Using regressions of hourly generation and emissions data from 2006 through 2011, I estimate regional MEFs for CO2, NO x, and SO2, as well as the share of marginal generation from coal-, gas-, and oil-fired generators. This work highlights significant regional differences in the emissions benefits of displacing a unit of electricity: compared to the West, displacing one megawatt-hour of electricity in the Midwest is expected to avoid roughly 70% more CO2, 12 times more SO 2, and 3 times more NOx emissions. I go on to explore regional variations in the performance of wind turbines and solar panels, where performance is measured relative to three objectives: energy production, avoided CO2 emissions, and avoided health and environmental damages from criteria pollutants. For 22 regions of the United States, I use regressions of historic emissions and generation data to estimate marginal impact factors, a measure of the avoided health and environmental damages per megawatt-hour of displaced electricity. Marginal impact factors are used to evaluate the effects of an additional wind turbine or solar panel in the U.S. electricity system. I find that the most attractive sites for renewables depend strongly on one's objective. A solar panel in Iowa displaces 20% more CO2 emissions than a panel in Arizona, though energy production from the Iowa panel is 25% less. Similarly, despite a modest wind resource, a wind turbine in West Virginia is expected to displace 7 times more health and environmental damages than a wind turbine in Oklahoma. Finally, I shift focus and explore the economics of small-scale cogeneration, which has long been recognized as a more efficient alternative to central-station power. Although the benefits of distributed cogeneration are widely cited, adoption has been slow in the U.S. Adoption could be encouraged by making cogeneration more economically attractive, either by increasing the expected returns or decreasing the risks of such investments. I present a case study of a 300-kilowatt cogeneration unit and evaluate the expected returns from: demand response, capacity markets, regulation markets, accelerated depreciation, a price on CO2 emissions, and net metering. In addition, I explore the effectiveness of feed-in tariffs at mitigating the energy-price risks to cogeneration projects.
Role of fuel cells in industrial cogeneration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Camara, E.H.
Work at the Institute of Gas Technology on fuel cell technology for commercial application has focused on phosphoric acid (PAFC), molten carbonate (MCFC), and solid oxide (SOFC) fuel cells. The author describes the status of the three technologies, and concludes that the MCFC in particular can efficiently supply energy in industrial cogeneration applications. The four largest industrial markets are primary metals, chemicals, food, and wood products, which collectively represent a potential market of 1000 to 1500 MEe annual additions. At $700 to $900/kW, fuel cells can successfully compete with other advanced systems. An increase in research and development support wouldmore » be in the best interest of industry and the nation. 1 reference, 5 figures, 5 tables.« less
ERIC Educational Resources Information Center
Hirsch, Thomas E., III; Shapiro, Robert F.
1986-01-01
Large institutional energy users can reduce energy costs by constructing and operating steam and electricity cogeneration facilities and purchasing their own gas at lower prices rather than relying on local distributors. (MSE)
Code of Federal Regulations, 2010 CFR
2010-01-01
... systems, building load simulation models, statistical regression analysis, or some combination of these..., excluding any cogeneration process for other than a federally owned building or buildings or other federally...
Feasibility analysis for biomass cogeneration at the Fort Apache Timber Company
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whittier, J.; Hasse, S.; Tomberlin, G.
1996-12-31
The Fort Apache Timber Company (FATCO) is a wholly-owned tribal enterprise of the White Mountain Apache Tribe (WMAT). WMAT officials are concerned about fuel buildup on the forest floor and the potential for catastrophic forests fires. Cogeneration is viewed as one means to effectively utilize biomass from the forest to reduce the chance of forest fires. FATCO presently spends approximately $1.6 million per year for electricity service from Navopache Electric Cooperative, Inc. for three sites. Peak demand is approximately 3.9 MW and the annual load factor is slightly under 50 percent. The blended cost of electricity is approximately $0.089 /more » kWh at the main mill. Biomass resources for fuel purposes may be obtained both from mill operations and from the forest operations. For many years FATCO has burned its wood residues to supply steam for dry kilns. It is estimated that a total of 125,778 bone dry tons (bdt) per year are available for fuel. A twenty year economic analysis model was used to evaluate the cogeneration potential. The model performs annual cash flow calculations to arrive at three measures of economic vitality: (1) Net Present Value (NPV), (2) levelized cost per kWh, and (3) Year 2 Return on Investment (ROI). Results of the analysis are positive for several scenarios.« less
Tempest gas turbine extends EGT product line
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chellini, R.
With the introduction of the 7.8 MW (mechanical output) Tempest gas turbine, ECT has extended the company`s line of its small industrial turbines. The new Tempest machine, featuring a 7.5 MW electric output and a 33% thermal efficiency, ranks above the company`s single-shaft Typhoon gas turbine, rated 3.2 and 4.9 MW, and the 6.3 MW Tornado gas turbine. All three machines are well-suited for use in combined heat and power (CHP) plants, as demonstrated by the fact that close to 50% of the 150 Typhoon units sold are for CHP applications. This experience has induced EGT, of Lincoln, England, tomore » announce the introduction of the new gas turbine prior to completion of the testing program. The present single-shaft machine is expected to be used mainly for industrial trial cogeneration. This market segment, covering the needs of paper mills, hospitals, chemical plants, ceramic industry, etc., is a typical local market. Cogeneration plants are engineered according to local needs and have to be assisted by local organizations. For this reason, to efficiently cover the world market, EGT has selected a number of associates that will receive from Lincoln completely engineered machine packages and will engineer the cogeneration system according to custom requirements. These partners will also assist the customer and dispose locally of the spares required for maintenance operations.« less
1170 MW/sub t/ HTGR steamer cogeneration plant: design and cost study
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
A conceptual design and cost study is presented for intermediate size high temperature gas-cooled reactor (HTGR) for industrial energy applications performed by United Engineers and Constructors Inc., (UE and C) and The General Atomic Company (GAC). The study is part of a program at ORNL and has the objective to provide support in the evaluation of the technical and economic feasibility of a single unit 1170 MW/sub t/ HTGR steam cycle cogeneration plant (referred to as the Steamer plant) for the production of industrial process energy. Inherent in the achievement of this objective, it was essential to perform a numbermore » of basic tasks such as the development of plant concept, capital cost estimate, project schedule and annual operation and maintenance (O and M) cost.« less
The predictive protective control of the heat exchanger
NASA Astrophysics Data System (ADS)
Nevriva, Pavel; Filipova, Blanka; Vilimec, Ladislav
2016-06-01
The paper deals with the predictive control applied to flexible cogeneration energy system FES. FES was designed and developed by the VITKOVICE POWER ENGINEERING joint-stock company and represents a new solution of decentralized cogeneration energy sources. In FES, the heating medium is flue gas generated by combustion of a solid fuel. The heated medium is power gas, which is a gas mixture of air and water steam. Power gas is superheated in the main heat exchanger and led to gas turbines. To protect the main heat exchanger against damage by overheating, the novel predictive protective control based on the mathematical model of exchanger was developed. The paper describes the principle, the design and the simulation of the predictive protective method applied to main heat exchanger of FES.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothkopf, M.H.; Kahn, E.P.; Teisberg, T.J.
The Public Utilities Regulatory Act (PURPA) requires there to be procedures for electric utilities to buy electric power from qualifying cogenerators and small power producers (QFs) at rates up to ''avoided cost.'' This has led to price-posting procedures at prices calculated as the utility's marginal cost. Unexpectedly large sales at these prices and slow adjustment to falling energy cost are partially responsible for payments to QFs in excess of the utility's true avoided cost. Using competitive bidding instead of posted prices has been proposed as a way to avoid this outcome. This report reviews bidding theory and explores four issuesmore » that arise in deisigning auction systems for the purchase of power from QFs under PURPA. 77 refs., 6 figs., 15 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Public Utilities Regulatory Act (PURPA) requires there to be procedures for electric utilities to buy electric power from qualifying cogenerators and small power producers (QFs) at rates up to ''avoided cost''. This has led to price-posting procedures at prices calculated as the utility's marginal cost. Unexpectedly large sales at these prices and slow adjustment to falling energy cost are partially responsible for payments to QFs in excess of the utility's true avoided cost. Using competitive bidding instead of posted prices has been proposed as a way to avoid this outcome. This report reviews bidding theory and explores four issuesmore » that arise in designing auction systems for the purchase of power from QFs under PURPA.« less
77 FR 43585 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
...: LAFOURCHE SUGARS, LLC. Description: Form 556--Notice of Self-Certification for Qualifying Cogeneration Facility Status of LAFOURCHE SUGARS, LLC. Filed Date: 7/17/12. Accession Number: 20120717-5137. Comments...
Study on the Effect of a Cogeneration System Capacity on its CO2 Emissions
NASA Astrophysics Data System (ADS)
Fonseca, J. G. S., Jr.; Asano, Hitoshi; Fujii, Terushige; Hirasawa, Shigeki
With the global warming problem aggravating and subsequent implementation of the Kyoto Protocol, CO2 emissions are becoming an important factor when verifying the usability of cogeneration systems. Considering this, the purpose of this work is to study the effect of the capacity of a cogeneration system on its CO2 emissions under two kinds of operation strategies: one focused on exergetic efficiency and another on running cost. The system meets the demand pattern typical of a hospital in Japan, operating during one year with an average heat-to-power ratio of 1.3. The main equipments of the cogeneration system are: a gas turbine with waste heat boiler, a main boiler and an auxiliary steam turbine. Each of these equipments was characterized with partial load models, and the turbine efficiencies at full load changed according to the system capacity. Still, it was assumed that eventual surplus of electricity generated could be sold. The main results showed that for any of the capacities simulated, an exergetic efficiency-focused operational strategy always resulted in higher CO2 emissions reduction when compared to the running cost-focused strategy. Furthermore, the amount of reduction in emissions decreased when the system capacity decreased, reaching a value of 1.6% when the system capacity was 33% of the maximum electricity demand with a heat-to-power ratio of 4.1. When the system operated focused on running cost, the economic savings increased with the capacity and reached 42% for a system capacity of 80% of maximum electricity demand and with a heat-to-power ratio of 2.3. In such conditions however, there was an increase in emissions of 8.5%. Still for the same capacity, an exergetic efficiency operation strategy presented the best balance between cost and emissions, generating economic savings of 29% with a decrease in CO2 emissions of 7.1%. The results found showed the importance of an exergy-focused operational strategy and also indicated that lower capacities resulted in lesser gains of both CO2 emissions and running cost reduction.
HOMER® Energy Modeling Software 2003
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2003-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
HOMER® Energy Modeling Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2000-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
EPA and DOJ announced a Clean Air Act settlement with Minnesota Power, an ALLETE company based in Duluth, that will cover its three coal-fired power plants and one biomass-and-coal-fired steam and electricity cogeneration plan
Case study of McCormick place cogeneration project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Overstreet, E.L.
1994-12-31
In the authors business of providing district energy services, competition is the key to his being able to have a positive impact on the environment, business stability, and economic activity. In the district energy industry, the competitive options are for property owners to continue to self generate energy to meet their needs, purchase energy from a company that utilizes electricity during off-peak hours to produce chilled water or take advantage of a total solution of purchasing tri-generation energy from Trigen-Peoples District Energy Company. Tri-generation is an innovative technology which involves the simultaneous production of steam, chilled water, and electricity. Themore » McCormick Place cogeneration project calls for producing steam and chilled water (co-) for use by the Metropolitan Pier and Exposition Authority (MPEA). The plant will produce electricity (tri-) to run the production equipment.« less
Thermophotovoltaic systems for civilian and industrial applications in Japan
NASA Astrophysics Data System (ADS)
Yugami, Hiroo; Sasa, Hiromi; Yamaguchi, Masafumi
2003-05-01
The potential market for thermophotovoltaic (TPV) applications has been studied for civilian and industrial sectors in Japan. Comparing the performance of gas engines or turbines, as well as the underdeveloped power generation technologies such as fuel cells or chemical batteries, we have discussed the feasible application field of TPV systems to compete with those power generations. From the point of view of applicability for TPV systems in Japan, portable generators, co-generation systems and solar power plants are selected for our system analysis. The cost and performance targets of TPV systems for co-generation are also discussed by assuming a typical daily profile of electricity and hot water demands in Japanese homes. A progress report on the recent TPV research activities is given as well as a feasibility study concerning such TPV systems in Japan.
Moorhead district heating, phase 2
NASA Astrophysics Data System (ADS)
Sundberg, R. E.
1981-01-01
The feasibility of developing a demonstration cogeneration hot water district heating system was studied. The district heating system would use coal and cogenerated heat from the Moorhead power plant to heat the water that would be distributed through underground pipes to customers or their space and domestic water heating needs, serving a substantial portion of the commercial and institutional loads as well as single and multiple family residences near the distribution lines. The technical feasibility effort considered the distribution network, retrofit of the power plant, and conversion of heating systems in customers' buildings to use hot water from the system. The system would be developed over six years. The economic analysis consisted of a market assessment and development of business plans for construction and operation of the system. Rate design methodology, institutional issues, development risk, and the proposal for implementation are discussed.
NASA Astrophysics Data System (ADS)
Sahu, S. K.; Ohara, T.; Beig, G.; Kurokawa, J.; Nagashima, T.
2015-09-01
In the recent past, the emerging India economy is highly dependent on conventional as well as renewable energy to deal with energy security. Keeping the potential of biomass and its plentiful availability, the Indian government has been encouraging various industrial sectors to generate their own energy from it. The Indian sugar industry has adopted and made impressive growth in bagasse (a renewable biomass, i.e. left after sugercane is crushed) based cogeneration power to fulfil their energy need, as well as to export a big chunk of energy to grid power. Like fossil fuel, bagasse combustion also generates various critical pollutants. This article provides the first ever estimation, current status and overview of magnitude of air pollutant emissions from rapidly growing bagasse based cogeneration technology in Indian sugar mills. The estimated emission from the world’s second largest sugar industry in India for particulate matter, NOX, SO2, CO and CO2 is estimated to be 444 ± 225 Gg yr-1, 188 ± 95 Gg yr-1, 43 ± 22 Gg yr-1, 463 ± 240 Gg yr-1 and 47.4 ± 9 Tg yr-1, respectively in 2014. The studies also analyze and identify potential hot spot regions across the country and explore the possible further potential growth for this sector. This first ever estimation not only improves the existing national emission inventory, but is also useful in chemical transport modeling studies, as well as for policy makers.
Relation of peer effects and school climate to substance use among Asian American adolescents.
Ryabov, Igor
2015-07-01
Using a nationally representative, longitudinal sample of Asian American late adolescents/young adults (ages 18-26), this article investigates the link between peer effects, school climate, on the one hand, and substance use, which includes tobacco, alcohol, and other illicit mood altering substance. The sample (N = 1585) is drawn from the National Longitudinal Study of Adolescent Health (Waves I and III). The study is set to empirically test premises of generational, social capital and stage-environment fit theories. The exploratory variables include individual-level (immigrant generation status, ethnic origin, co-ethnic and co-generational peers - peers from the same immigrant generation) as well as school-level measures (average school socio-economic status and school climate). Multilevel modeling (logistic and negative binomial regression) was used to estimate substance use. Results indicate that preference for co-generational friends is inversely associated with frequency of cannabis and other illicit drug use and preference for co-ethnic peers is inversely associated with other illicit drug use. We also find that school climate is a strong and negative predictor of frequency of cannabis and other illicit drug use as well as of heavy episodic drinking. In terms of policy, these findings suggest that Asian American students should benefit from co-ethnic and co-generational peer networks in schools and, above all, from improving school climate. Copyright © 2015 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.
Economically dispatching cogeneration facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, E.
Economic dispatching has been used by utilities to meet the energy demands of their customers for decades. The objective was to first load those units which cost the least to run and slowly increase the loading of more expensive units as the incremental energy price increased. Although this concept worked well for utility based systems where incremental costs rose with peak demand, the independent power producers(IPPs) and the power purchase agreements (PPAs) have drastically changed this notion. Most PPAs structured for the IPP environment have negotiated rates which remain the same during peak periods and base their electrical generation onmore » specific process steam requirements. They also must maintain the required production balance of process steam and electrical load in order to qualify as a Public Utility Regulatory Policies Act (PURPA) facility. Consequently, economically dispatching Cogeneration facilities becomes an exercise in adhering to contractual guidelines while operating the equipment in the most efficient manner possible for the given condition. How then is it possible to dispatch a Cogeneration facility that maintains the electrical load demand of JFK Airport while satisfying all of its heating and cooling needs? Contractually, Kennedy International Airport Cogen (KIAC) has specific obligations concerning electrical and thermal energy exported to JFK Airport. The facility`s impressive array of heating and cooling apparatuses together with the newly installed cogen fulfilled the airport`s needs by utilizing an endless combination of new and previously installed equipment. Moreover, in order to economically operate the plant a well structured operating curriculum was necessary.« less
NASA Astrophysics Data System (ADS)
Lockwood, Timothy A.
Federal legislative changes in 2006 no longer entitle cogeneration project financings by law to receive the benefit of a power purchase agreement underwritten by an investment-grade investor-owned utility. Consequently, this research explored the need for a new market-risk model for future cogeneration and combined heat and power (CHP) project financing. CHP project investment represents a potentially enormous energy efficiency benefit through its application by reducing fossil fuel use up to 55% when compared to traditional energy generation, and concurrently eliminates constituent air emissions up to 50%, including global warming gases. As a supplemental approach to a comprehensive technical analysis, a quantitative multivariate modeling was also used to test the statistical validity and reliability of host facility energy demand and CHP supply ratios in predicting the economic performance of CHP project financing. The resulting analytical models, although not statistically reliable at this time, suggest a radically simplified CHP design method for future profitable CHP investments using four easily attainable energy ratios. This design method shows that financially successful CHP adoption occurs when the average system heat-to-power-ratio supply is less than or equal to the average host-convertible-energy-ratio, and when the average nominally-rated capacity is less than average host facility-load-factor demands. New CHP investments can play a role in solving the world-wide problem of accommodating growing energy demand while preserving our precious and irreplaceable air quality for future generations.
HOMER® Energy Modeling Software V2.63
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2003-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
HOMER® Energy Modeling Software V2.64
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2003-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
HOMER® Energy Modeling Software V2.65
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2008-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
HOMER® Energy Modeling Software V2.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2003-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
HOMER® Energy Modeling Software V2.19
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2008-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
HOMER® Energy Modeling Software V2.67
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambert, Tom
2008-12-31
The HOMER® energy modeling software is a tool for designing and analyzing hybrid power systems, which contain a mix of conventional generators, cogeneration, wind turbines, solar photovoltaic, hydropower, batteries, fuel cells, hydropower, biomass and other inputs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polimeros, G.
1981-01-01
Design criteria for central plants that facilitate energy conversion, utilization, and conservation, an evaluation of project alternatives and an examination of systems and their functions to achieve optimum overall design in the generation of heating, cooling, and electricity are presented.
Operating results of a KU30 diesel cogeneration plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shioda, Kiyoshi; Kakinuma, Takashi; Nishido, Takashi
1995-11-01
Diesel cogeneration plants provide high generation ratios, the ability to operate on heavy fuel oil, small space requirements, short delivery terms and easy starting and stopping. The Mitsubishi type KU30 diesel engine is well-suited for meeting the demands of these applications. The KU30 engine (bore 300 x stroke 380 mm) covers an output range from 3500 to 5000 kW at 720 or 750 r/min. Performance results show that total power failures have completely disappeared, thanks to improvements in stable power supply and the reliability of the power source. They also show that the rate of private power generation has accountedmore » for more than 90% of total power consumption in the plant, and that the unit cost of electric power could be reduced by three yen (per kilowatt hour) compared with that of purchased power. This paper describes the design and operating results from a typical plant.« less
Quintero, Julián A; Moncada, Jonathan; Cardona, Carlos A
2013-07-01
In this study a techno-economic analysis of the production of bioethanol from four lignocellusic (Sugarcane bagasse, Coffee cut-stems, Rice Husk, and Empty Fruit Bunches) residues is presented for the Colombian case. The ethanol production was evaluated using Aspen Plus and Aspen Process Economic Analyzer carrying out the simulation and the economic evaluation, respectively. Simulations included the composition of lignocellulosic residues, which was determined experimentally. It was found that empty fruit bunches presents the highest ethanol yield from a dry basis point of view (313.83 L/t), while rice husk produced less ethanol (250.56 L/t). The ethanol production cost was assessed for the standalone ethanol plant and the ethanol plant coupled with a cogeneration system. Moreover, ethanol production cost using EFB was the lowest with (0.49 US$/L) and without (0.58 US$/L) cogeneration scheme. Copyright © 2013 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-08
...The Department of Commerce is conducting an administrative review of the countervailing duty order on citric acid and certain citrate salts from the People's Republic of China for the period September 19, 2008, through December 31, 2009. We preliminarily find that RZBC Co., Ltd. (``RZBC Co.''); RZBC Import & Export Co., Ltd. (``RZBC I&E''); RZBC (Juxian) Co., Ltd. (``RZBC Juxian''); and RZBC Group Co., Ltd. (``RZBC Group'') (collectively, ``RZBC''), and Yixing Union Biochemical Co., Ltd. (``Yixing Union Co.) and Yixing Union Cogeneration Co., Ltd. (``Cogeneration'') (collectively, ``Yixing Union'') received countervailable subsidies during the period of review. If these preliminary results are adopted in our final results of this review, we will instruct U.S. Customs and Border Protection to assess countervailing duties as detailed in the ``Preliminary Results of Review'' section of this notice. Interested parties are invited to comment on these preliminary results.
Dual comb generation from a mode-locked fiber laser with orthogonally polarized interlaced pulses.
Akosman, Ahmet E; Sander, Michelle Y
2017-08-07
Ultra-high precision dual-comb spectroscopy traditionally requires two mode-locked, fully stabilized lasers with complex feedback electronics. We present a novel mode-locked operation regime in a thulium-holmium co-doped fiber laser, a frequency-halved state with orthogonally polarized interlaced pulses, for dual comb generation from a single source. In a linear fiber laser cavity, an ultrafast pulse train composed of co-generated, equal intensity and orthogonally polarized consecutive pulses at half of the fundamental repetition rate is demonstrated based on vector solitons. Upon optical interference of the orthogonally polarized pulse trains, two stable microwave RF beat combs are formed, effectively down-converting the optical properties into the microwave regime. These co-generated, dual polarization interlaced pulse trains, from one all-fiber laser configuration with common mode suppression, thus provide an attractive compact source for dual-comb spectroscopy, optical metrology and polarization entanglement measurements.
Commissioning and Performance Analysis of WhisperGen Stirling Engine
NASA Astrophysics Data System (ADS)
Pradip, Prashant Kaliram
Stirling engine based cogeneration systems have potential to reduce energy consumption and greenhouse gas emission, due to their high cogeneration efficiency and emission control due to steady external combustion. To date, most studies on this unit have focused on performance based on both experimentation and computer models, and lack experimental data for diversified operating ranges. This thesis starts with the commissioning of a WhisperGen Stirling engine with components and instrumentation to evaluate power and thermal performance of the system. Next, a parametric study on primary engine variables, including air, diesel, and coolant flowrate and temperature were carried out to further understand their effect on engine power and efficiency. Then, this trend was validated with the thermodynamic model developed for the energy analysis of a Stirling cycle. Finally, the energy balance of the Stirling engine was compared without and with heat recovery from the engine block and the combustion chamber exhaust.
Klickitat Cogeneration Project : Final Environmental Assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
United States. Bonneville Power Administration; Klickitat Energy Partners
1994-09-01
To meet BPA`s contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA`s proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2)more » impacts to fisheries, wildlife resources, air quality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not required and BPA is issuing this FONSI (Finding of No Significant Impact).« less
NASA Technical Reports Server (NTRS)
1982-01-01
The essential elements of the cogeneration system configuration to be captured were the displacement of thermal energy by collection and use of the Brayton exhaust stream, and the sale back to the utility of any electricity production in excess of on-site requirements. In contrast to simply dumping these energy flows, their use or sale obviously serves, by itself, to increase gross value of the solar thermal energy system. Net allowable cost of the parabolic dish modules may or may not be increased, however. A consideration is that the waste heat capture and delivery subsystems are not free. This study does not address the incremental cost of adding waste heat capture, transport, and conversion (to steam, if necessary). It does compute a value for the thermal energy thereby displaced. This value can serve as a first-round input to any detailed economic evaluation of waste heat recovery.
CSP cogeneration of electricity and desalinated water at the Pentakomo field facility
NASA Astrophysics Data System (ADS)
Papanicolas, C. N.; Bonanos, A. M.; Georgiou, M. C.; Guillen, E.; Jarraud, N.; Marakkos, C.; Montenon, A.; Stiliaris, E.; Tsioli, E.; Tzamtzis, G.; Votyakov, E. V.
2016-05-01
The Cyprus Institute's Pentakomo Field Facility (PFF) is a major infrastructure for research, development and testing of technologies relating to concentrated solar power (CSP) and solar seawater desalination. It is located at the south coast of Cyprus near the sea and its environmental conditions are fully monitored. It provides a test facility specializing in the development of CSP systems suitable for island and coastal environments with particular emphasis on small units (<25 MWth) endowed with substantial storage, suitable for use in isolation or distributed in small power grids. The first major experiment to take place at the PFF concerns the development of a pilot/experimental facility for the co-generation of electricity and desalinated seawater from CSP. Specifically, the experimental plant consists of a heliostat-central receiver system for solar harvesting, thermal energy storage in molten salts followed by a Rankine cycle for electricity production and a multiple-effect distillation (MED) unit for desalination.
Cogeneration steam turbines from Siemens: New solutions
NASA Astrophysics Data System (ADS)
Kasilov, V. F.; Kholodkov, S. V.
2017-03-01
The Enhanced Platform system intended for the design and manufacture of Siemens AG turbines is presented. It combines organizational and production measures allowing the production of various types of steam-turbine units with a power of up to 250 MWel from standard components. The Enhanced Platform designs feature higher efficiency, improved reliability, better flexibility, longer overhaul intervals, and lower production costs. The design features of SST-700 and SST-900 steam turbines are outlined. The SST-700 turbine is used in backpressure steam-turbine units (STU) or as a high-pressure cylinder in a two-cylinder condensing turbine with steam reheat. The design of an SST-700 single-cylinder turbine with a casing without horizontal split featuring better flexibility of the turbine unit is presented. An SST-900 turbine can be used as a combined IP and LP cylinder (IPLPC) in steam-turbine or combined-cycle power units with steam reheat. The arrangements of a turbine unit based on a combination of SST-700 and SST-900 turbines or SST-500 and SST-800 turbines are presented. Examples of this combination include, respectively, PGU-410 combinedcycle units (CCU) with a condensing turbine and PGU-420 CCUs with a cogeneration turbine. The main equipment items of a PGU-410 CCU comprise an SGT5-4000F gas-turbine unit (GTU) and STU consisting of SST-700 and SST-900RH steam turbines. The steam-turbine section of a PGU-420 cogeneration power unit has a single-shaft turbine unit with two SST-800 turbines and one SST-500 turbine giving a power output of N el. STU = 150 MW under condensing conditions.
LIFE CYCLE ASSESSMENT OF ELECTRICITY GENERATION ALTERNATIVES
This presentation summarizes various electricity and electricity/steam cogeneration alternatives. Among these alternatives, are fossil fuel and biomass power generation plants. These plants have different designs due to the need in fossil fuel (coal) plants to include process u...
CHP, also known as cogeneration, is the simultaneous production of electricity and heat from a single fuel source. Read more about recommendations for designing, implementing, and evaluating combined heat and power.
18 CFR 292.308 - Standards for operating reliability.
Code of Federal Regulations, 2010 CFR
2010-04-01
... reliability. 292.308 Section 292.308 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying... may establish reasonable standards to ensure system safety and reliability of interconnected...
Energy Conservation: Three Projects That Worked.
ERIC Educational Resources Information Center
American School and University, 1981
1981-01-01
Compact design and insulation cut energy use at a junior high school in Rexon (New Brunswick). Loma Linda University in California has reduced consumption of natural gas by installing cogeneration equipment. Morningside College in Sioux City (Iowa) has replaced deteriorating windows. (Author/MLF)
75 FR 23753 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-04
... Numbers: QF10-13-000. Applicants: Cornell University. Description: Self Certification of Cogeneration Facility Cornell University (NY). Filed Date: 10/08/2009. Accession Number: 20091008-5041. Comment Date... Applicable. Docket Numbers: QF10-431-000. Applicants: Oregon State University. Description: Self...
Low NOx combustion using cogenerated oxygen and nitrogen streams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayashi, Hisashi; Bool, Lawrence E; Snyder, William J
Combustion of hydrocarbon fuel is achieved with less formation of NOx by feeding the fuel into a slightly oxygen-enriched atmosphere, and separating air into oxygen-rich and nitrogen-rich streams which are fed separately into the combustion device.
77 FR 54907 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric rate filings: Docket Numbers: ER10-2601-001; ER10-2605-003. Applicants: Power Resources, Ltd., Yuma Cogeneration Associates. Description: Notification of...
Higher Education Facilities: The SmartGrid Earns a Doctorate in Economics
ERIC Educational Resources Information Center
Tysseling, John C.; Zibelman, Audrey; Freifeld, Allen
2011-01-01
Most higher education facilities have already accomplished some measure of a "microgrid" investment with building control systems (BCS), energy management systems (EMS), and advanced metering infrastructure (AMI) installations. Available energy production facilities may include boilers, chillers, cogeneration, thermal storage, electrical…
Concept of turbines for ultrasupercritical, supercritical, and subcritical steam conditions
NASA Astrophysics Data System (ADS)
Mikhailov, V. E.; Khomenok, L. A.; Pichugin, I. I.; Kovalev, I. A.; Bozhko, V. V.; Vladimirskii, O. A.; Zaitsev, I. V.; Kachuriner, Yu. Ya.; Nosovitskii, I. A.; Orlik, V. G.
2017-11-01
The article describes the design features of condensing turbines for ultrasupercritical initial steam conditions (USSC) and large-capacity cogeneration turbines for super- and subcritical steam conditions having increased steam extractions for district heating purposes. For improving the efficiency and reliability indicators of USSC turbines, it is proposed to use forced cooling of the head high-temperature thermally stressed parts of the high- and intermediate-pressure rotors, reaction-type blades of the high-pressure cylinder (HPC) and at least the first stages of the intermediate-pressure cylinder (IPC), the double-wall HPC casing with narrow flanges of its horizontal joints, a rigid HPC rotor, an extended system of regenerative steam extractions without using extractions from the HPC flow path, and the low-pressure cylinder's inner casing moving in accordance with the IPC thermal expansions. For cogeneration turbines, it is proposed to shift the upper district heating extraction (or its significant part) to the feedwater pump turbine, which will make it possible to improve the turbine plant efficiency and arrange both district heating extractions in the IPC. In addition, in the case of using a disengaging coupling or precision conical bolts in the coupling, this solution will make it possible to disconnect the LPC in shifting the turbine to operate in the cogeneration mode. The article points out the need to intensify turbine development efforts with the use of modern methods for improving their efficiency and reliability involving, in particular, the use of relatively short 3D blades, last stages fitted with longer rotor blades, evaporation techniques for removing moisture in the last-stage diaphragm, and LPC rotor blades with radial grooves on their leading edges.
Feasibility Evaluation of an On-site Generator Network by the Cooperative Game Theory
NASA Astrophysics Data System (ADS)
Komiyama, Ryoichi; Hayashi, Taketo; Fujii, Yasumasa; Yamaji, Kenji
On-site generator, such as CGS (cogeneration system), is allegedly considered to be an effective end-use energy system in order to accomplish primary energy conservation, CO2 emission mitigation and system cost reduction, which characteristics eventually improve the whole performance of an existing energy system for the future. Considering the drawback of installing an end-use CGS into the customer with small or middle scale floor space, however, it is difficult to achieve those distinctive features because the thermal-electricity ratio of CGS does not always be in agreement with that of customer energy demand. In order to overcome that matching deficiency, it is hence better to organize an on-site generator network based on mutual electricity and heating transmission. But focusing on some cogenerators underlying their behaviors on maximizing their own profits, this on-site network, which situation corresponds to a grand coalition, is not necessarily established because of each cogenerator’s motivation to form a partial coalition and acquire its own profit as much as possible. In this paper, we attempt to analyze the optimal operation of an on-site generator network and identify by applying the nucleolus of the cooperative game theory the optimal benefit allocation strategy in order for the cogenerators to construct the network. Regarding the installation site of this network, the center of Tokyo area is assumed, which locational information includes floor space and so forth through a GIS (geographic information system) database. The results from the nucleolus suggest that all districts should impartially obtain the benefit from organizing network for the purpose of jointly attaining the system total cost reduction.
Clark, Malcolm W; Despland, Laure M; Lake, Neal J; Yee, Lachlan H; Anstoetz, Manuela; Arif, Elisabeth; Parr, Jeffery F; Doumit, Philip
2017-04-01
Sugarcane bagasse ash re-utilisation has been advocated as a silica-rich feed for zeolites, pozzolans in cements and concretes, and geopolymers. However, many papers report variable success with the incorporation of such materials in these products as the ash can be inconsistent in nature. Therefore, understanding what variables affect the ash quality in real mills and understanding the processes to characterise ashes is critical in predicting successful ash waste utilisation. This paper investigated sugarcane bagasse ash from three sugar mills (Northern NSW, Australia) where two are used for the co-generation of electricity. Data shows that the burn temperatures of the bagasse in the high-efficiency co-generation boilers are much higher than those reported at the temperature measuring points. Silica polymorph transitions indicate the high burn temperatures of ≈1550 °C, produces ash dominated α -quartz rather than expected α-cristobilite and amorphous silica; although α-cristobilite, and amorphous silica are present. Furthermore, burn temperatures must be ≤1700 °C, because of the absence of lechatelierite where silica fusing and globulisation dominates. Consequently, silica-mineralogy changes deactivate the bagasse ash by reducing silica solubility, thus making bagasse ash utilisation in synthetic zeolites, geopolymers, or a pozzolanic material in mortars and concretes more difficult. For the ashes investigated, use as a filler material in cements and concrete has the greatest potential. Reported mill boiler temperatures discrepancies and the physical characteristics of the ash, highlight the importance of accurate temperature monitoring at the combustion seat if bagasse ash quality is to be prioritised to ensure a usable final ash product.
78 FR 16848 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-19
... that the Commission received the following electric corporate filings: Docket Numbers: EC13-80-000... the Commission received the following electric rate filings: Docket Numbers: ER13-915-000. Applicants... Engineering. Description: Form 556--Notice of self-certification of qualifying cogeneration facility status of...
The U.S. EPA's Office of Research and Development operates the Environmental Technology Verification (ETV) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. Congress funds ETV in response to the belief ...
76 FR 44898 - Texas Eastern Transmission, LP; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-27
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-508-000] Texas Eastern... lateral line transportation service to the Grays Ferry Cogeneration Partnership (Grays Ferry) and..., the anticipated date for the Commission staff's issuance of the final environmental impact statement...
Code of Federal Regulations, 2011 CFR
2011-04-01
... Definitions. For purposes of this subpart: (a) Biomass means any organic material not derived from fossil.... (c) Cogeneration facility means equipment used to produce electric energy and forms of useful thermal... all forms supplied from external sources; (k) Natural gas means either natural gas unmixed, or any...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2014 CFR
2014-04-01
... Definitions. For purposes of this subpart: (a) Biomass means any organic material not derived from fossil.... (c) Cogeneration facility means equipment used to produce electric energy and forms of useful thermal... all forms supplied from external sources; (k) Natural gas means either natural gas unmixed, or any...
Code of Federal Regulations, 2010 CFR
2010-04-01
... Definitions. For purposes of this subpart: (a) Biomass means any organic material not derived from fossil.... (c) Cogeneration facility means equipment used to produce electric energy and forms of useful thermal... all forms supplied from external sources; (k) Natural gas means either natural gas unmixed, or any...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Definitions. For purposes of this subpart: (a) Biomass means any organic material not derived from fossil.... (c) Cogeneration facility means equipment used to produce electric energy and forms of useful thermal... all forms supplied from external sources; (k) Natural gas means either natural gas unmixed, or any...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2013 CFR
2013-04-01
... Definitions. For purposes of this subpart: (a) Biomass means any organic material not derived from fossil.... (c) Cogeneration facility means equipment used to produce electric energy and forms of useful thermal... all forms supplied from external sources; (k) Natural gas means either natural gas unmixed, or any...
76 FR 27035 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
... Power Resources Management, LLC, GDF SUEZ Energy Marketing NA, Inc., Hopewell Cogeneration Limited... & Company, Power Receivable Finance, LLC. Description: Land Acquisition Report of J. Aron & Company and Power Receivable Finance, LLC under LA11-1. Filed Date: 05/02/2011. Accession Number: 20110502-5534...
75 FR 7466 - Commission Information Collection Activities (FERC-912 1
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-19
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. IC09-912-001] Commission Information Collection Activities (FERC-912 \\1\\), Supplemental Notice February 3, 2010. AGENCY: Federal Energy Regulatory Commission. \\1\\ FERC-912 (``Cogeneration and Small Power Production, PURPA Section 210(m...
Large-scale Eucalyptus energy farms and power cogeneration
Robert C. Noroña
1983-01-01
A thorough evaluation of all factors possibly affecting a large-scale planting of eucalyptus is foremost in determining the cost effectiveness of the planned operation. Seven basic areas of concern must be analyzed:1. Species Selection 2. Site Preparation 3. Planting 4. Weed Control 5....
18 CFR 292.311 - Reinstatement of obligation to purchase.
Code of Federal Regulations, 2010 CFR
2010-04-01
... electric energy, a qualifying cogeneration facility, a qualifying small power production facility, a State... utility's obligation to purchase electric energy under this section. Such application shall set forth the... application reinstating the electric utility's obligation to purchase electric energy under this section if...
18 CFR 292.311 - Reinstatement of obligation to purchase.
Code of Federal Regulations, 2011 CFR
2011-04-01
... electric energy, a qualifying cogeneration facility, a qualifying small power production facility, a State... utility's obligation to purchase electric energy under this section. Such application shall set forth the... application reinstating the electric utility's obligation to purchase electric energy under this section if...
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, Yury N.
The co-generation nuclear power plant (CNPP) producing electricity and district heating heat is planned to be constructed in Archangelsk Region of Russia. Following the 'Letter of Intent' signed by Governor of Archangelsk region and by Minister of the Russian Federation for atomic energy the feasibility study of the Project has been done. The NPP will be based on the four co-generation nuclear power units with the Russian VK-300 SBWR. The innovative passive VK-300 reactor facility has been designed on the basis of well-established nuclear technologies, proven major components, the operating experience of the prototype VK-50 reactor in RIAR, Dimitrovgrad, andmore » the experience in designing such reactors as SBWR (GE) and SWR-1000 (Siemens). The CNPP's total power is planned to be 1000 MW(e) and district-heating heat production capacity 1600 Gcal/h. A detailed description of the results of the feasibility study is presented in the report. The results of the feasibility study have shown that the Archangelsk CGNP is feasible in terms of engineering, economics and production. (authors)« less
NASA Astrophysics Data System (ADS)
Ferreira, Ana C. M.; Teixeira, Senhorinha F. C. F.; Silva, Rui G.; Silva, Ângela M.
2018-04-01
Cogeneration allows the optimal use of the primary energy sources and significant reductions in carbon emissions. Its use has great potential for applications in the residential sector. This study aims to develop a methodology for thermal-economic optimisation of small-scale micro-gas turbine for cogeneration purposes, able to fulfil domestic energy needs with a thermal power out of 125 kW. A constrained non-linear optimisation model was built. The objective function is the maximisation of the annual worth from the combined heat and power, representing the balance between the annual incomes and the expenditures subject to physical and economic constraints. A genetic algorithm coded in the java programming language was developed. An optimal micro-gas turbine able to produce 103.5 kW of electrical power with a positive annual profit (i.e. 11,925 €/year) was disclosed. The investment can be recovered in 4 years and 9 months, which is less than half of system lifetime expectancy.
Lobato, L C S; Chernicharo, C A L; Pujatti, F J P; Martins, O M; Melo, G C B; Recio, A A R
2013-01-01
A small unit of cogeneration of energy and heat was tested at the Centre for Research and Training on Sanitation UFMG/COPASA - CePTS, located at the Arrudas Sewage Treatment Plant, in Belo Horizonte, Minas Gerais, Brazil. The unit consisted of an engine power generator adapted to run on biogas, a thermal dryer prototype and other peripherals (compressor, biogas storage tank, air blower, etc.). The heat from engine power generator exhaust gases was directed towards the thermal dryer prototype to dry the sludge and disinfect it. The results showed that the experimental apparatus is self-sufficient in electricity, even producing a surplus, available for other uses. The tests of drying and disinfection of sludge lasted 7 h, leading to an increase in solids content from 4 to 8% (50% reduction in sludge volume). Although the drying of sludge was not possible (only thickening was achieved), the disinfection process proved very effective, enabling the complete inactivation of helminth eggs.
Influence of System Operation Method on CO2 Emissions of PV/Solar Heat/Cogeneration System
NASA Astrophysics Data System (ADS)
Oke, Shinichiro; Kemmoku, Yoshishige; Takikawa, Hirofumi; Sakakibara, Tateki
A PV/solar heat/cogeneration system is assumed to be installed in a hotel. The system is operated with various operation methods: CO2 minimum operation, fees minimum operation, seasonal operation, daytime operation and heat demand following operation. Of these five operations, the former two are virtual operations that are operated with the dynamic programming method, and the latter three are actual operations. Computer simulation is implemented using hourly data of solar radiation intensity, atmospheric temperature, electric, cooling, heating and hot water supply demands for one year, and the life-cycle CO2 emission and the total cost are calculated for every operations. The calculation results show that the virtual two and the actual three operations reduce the life-cycle CO2 emission by 21% and 13% compared with the conventional system, respectively. In regard to both the CO2 emission and the cost, there is no significant difference between the virtual two operation methods or among actual three operation methods.
Becker, Adilson M; Yu, Kevin; Stadler, Lauren B; Smith, Adam L
2017-01-01
Food waste is increasingly viewed as a resource that should be diverted from landfills. This study used life cycle assessment to compare co-management of food waste and domestic wastewater using anaerobic membrane bioreactor (AnMBR) against conventional activated sludge (CAS) and high rate activated sludge (HRAS) with three disposal options for food waste: landfilling (LF), anaerobic digestion (AD), and composting (CP). Based on the net energy balance (NEB), AnMBR and HRAS/AD were the most attractive scenarios due to cogeneration of produced biogas. However, cogeneration negatively impacted carcinogenics, non-carcinogenics, and ozone depletion, illustrating unavoidable tradeoffs between energy recovery from biogas and environmental impacts. Fugitive emissions of methane severely increased global warming impacts of all scenarios except HRAS/AD with AnMBR particularly affected by effluent dissolved methane emissions. AnMBR was also most sensitive to food waste diversion participation, with 40% diversion necessary to achieve a positive NEB at the current state of development. Copyright © 2016 Elsevier Ltd. All rights reserved.
Analysis on Operating Parameter Design to Steam Methane Reforming in Heat Application RDE
NASA Astrophysics Data System (ADS)
Dibyo, Sukmanto; Sunaryo, Geni Rina; Bakhri, Syaiful; Zuhair; Irianto, Ign. Djoko
2018-02-01
The high temperature reactor has been developed with various power capacities and can produce electricity and heat application. One of heat application is used for hydrogen production. Most hydrogen production occurs by steam reforming that operated at high temperature. This study aims to analyze the feasibility of heat application design of RDE reactor in the steam methane reforming for hydrogen production using the ChemCAD software. The outlet temperature of cogeneration heat exchanger is analyzed to be applied as a feed of steam reformer. Furthermore, the additional heater and calculating amount of fuel usage are described. Results show that at a low mass flow rate of feed, its can produce a temperature up to 480°C. To achieve the temperature of steam methane reforming of 850°C the additional fired heater was required. By the fired heater, an amount of fuel usage is required depending on the Reformer feed temperature produced from the heat exchanger of the cogeneration system.
NASA Astrophysics Data System (ADS)
Grigor'ev, S. A.; Grigor'ev, A. S.; Kuleshov, N. V.; Fateev, V. N.; Kuleshov, V. N.
2015-02-01
The layout of a combined heat and power (cogeneration) plant based on renewable energy sources (RESs) and hydrogen electrochemical systems for the accumulation of energy via the direct and inverse conversion of the electrical energy from RESs into the chemical energy of hydrogen with the storage of the latter is described. Some efficient technical solutions on the use of electrochemical hydrogen systems in power engineering for the storage of energy with a cyclic energy conversion efficiency of more than 40% are proposed. It is shown that the storage of energy in the form of hydrogen is environmentally safe and considerably surpasses traditional accumulator batteries by its capacitance characteristics, being especially topical in the prolonged absence of energy supply from RESs, e.g., under the conditions of polar night and breathless weather. To provide the required heat consumption of an object during the peak period, it is proposed to burn some hydrogen in a boiler house.
Survey on the possibility of introducing new energy to regional development plans
NASA Astrophysics Data System (ADS)
1988-03-01
This report covers nationwide large-scale resort plans and at the same time studies the possibility of introducing new energy systems, mainly cogeneration, and their effects. Japanese industrial structure is rapidly moving toward information and service areas, and the development of resorts has become very active. With the increase of resort demands, much is expected of resort development as a means of regional promotion. Special features of energy consumption in resort facilities are that annual demand is large, that energy consumption fluctuates greatly, and that energy supply cost is high. These features are especially conspicuous in smaller facilities. Most suited for resort lodging facilities is a co-generation system, especially a diesel engine system. This system is expected to conserve energy; but to promote this system, it is necessary to revise the preferential tax treatment and Fire Service Act to meet the actual circumstances, and to develop a highly reliable system that can be operated unattended. An economical system in view of overall costs is also essential.
Origins, characteristics, controls, and economic viabilities of deep- basin gas resources
Price, L.C.
1995-01-01
Dry-gas deposits (methane ???95% of the hydrocarbon (HC) gases) are thought to originate from in-reservoir thermal cracking of oil and C2+ HC gases to methane. However, because methanes from Anadarko Basin dry-gas deposits do not carry the isotopic signature characteristics of C15+ HC destruction, an origin of these methanes from this process is considered improbable. Instead, the isotopic signature of these methanes suggests that they were cogenerated with C15+ HC's. Only a limited resource of deep-basin gas deposits may be expected by the accepted model for the origin of dry-gas deposits because of a limited number of deep-basin oil deposits originally available to be thermally converted to dry gas. However, by the models of this paper (inefficient source-rock oil and gas expulsion, closed fluid systems in petroleum-basin depocenters, and most dry-gas methane cogenerated with C15+ HC's), very large, previously unrecognized, unconventional, deep-basin gas resources are expected. -from Author
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The goals of this study were to explore the magnitude of potential fuel savings (or increased fuel consumption) under different possible combinations of Qualifying Facilities generation and utility displacement, and to identify those combinations which might result in a net increase in fuel consumption. In exploring the impact of cogeneration net heat rate on net savings (or increase) in fuel consumption, the study also addressed the extent to which cogenerator efficiency affects the overall fuel use impact of Public Utility Regulatory Policies Act (PURPA) implementation. This research thus seeks to identify possible scenarios in which PURPA implementation may not resultmore » in the conversation of fossil fuels, and to define possible situations in which the FERC's efficiency standard may lead to energy-inefficient Qualifying Facility development. 9 refs., 6 figs., 6 tabs.« less
Cogeneration Technology Alternatives Study (CTAS). Volume 4: Energy conversion systems
NASA Technical Reports Server (NTRS)
Brown, D. H.; Gerlaugh, H. E.; Priestley, R. R.
1980-01-01
Industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed-cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum-based residual and distillate liquid fuels, and low Btu gas obtained through the on-site gasification of coal. An attempt was made to use consistent assumptions and a consistent set of ground rules specified by NASA for determining performance and cost. The advanced and commercially available cogeneration energy conversion systems studied in CTAS are fined together with their performance, capital costs, and the research and developments required to bring them to this level of performance.
Bechara, Rami; Gomez, Adrien; Saint-Antonin, Valérie; Schweitzer, Jean-Marc; Maréchal, François
2016-08-01
The application of methodologies for the optimal design of integrated processes has seen increased interest in literature. This article builds on previous works and applies a systematic methodology to an integrated first and second generation ethanol production plant with power cogeneration. The methodology breaks into process simulation, heat integration, thermo-economic evaluation, exergy efficiency vs. capital costs, multi-variable, evolutionary optimization, and process selection via profitability maximization. Optimization generated Pareto solutions with exergy efficiency ranging between 39.2% and 44.4% and capital costs from 210M$ to 390M$. The Net Present Value was positive for only two scenarios and for low efficiency, low hydrolysis points. The minimum cellulosic ethanol selling price was sought to obtain a maximum NPV of zero for high efficiency, high hydrolysis alternatives. The obtained optimal configuration presented maximum exergy efficiency, hydrolyzed bagasse fraction, capital costs and ethanol production rate, and minimum cooling water consumption and power production rate. Copyright © 2016 Elsevier Ltd. All rights reserved.
Thermal performance of a prototype plate heat exchanger with minichannels under boiling conditions
NASA Astrophysics Data System (ADS)
Wajs, J.; Mikielewicz, D.; Fornalik-Wajs, E.
2016-09-01
To solve the problem and to meet the requirements of customers in the field of high heat fluxes transfer in compact units, a new design of plate heat exchanger with minichannels (minichannels PHE) was proposed. The aim was to construct a compact heat exchanger of high effectiveness for the purpose of household cogeneration ORC system. In this paper the experimental analysis of an assembled prototype of such compact heat exchanger was described. The attention was paid to its thermal performance and the heat transfer coefficients under the boiling conditions. Water and ethanol were chosen as working fluids. The maximal value of transferred heat flux was about 84 kW/m2, while of the overall heat transfer coefficient was about 4000 W/(m2K). Estimated values of heat transfer coefficient on the ethanol (boiling) side reached the level of 7500 W/(m2K). The results are promising in the light of future applications, for example in cogeneration ORC systems, however further systematic investigations are necessary.
Smart grid integration of small-scale trigeneration systems
NASA Astrophysics Data System (ADS)
Vacheva, Gergana; Kanchev, Hristiyan; Hinov, Nikolay
2017-12-01
This paper presents a study on the possibilities for implementation of local heating, air-conditioning and electricity generation (trigeneration) as distributed energy resource in the Smart Grid. By the means of microturbine-based generators and absorption chillers buildings are able to meet partially or entirely their electrical load curve or even supply power to the grid by following their heating and air-conditioning daily schedule. The principles of small-scale cooling, heating and power generation systems are presented at first, then the thermal calculations of an example building are performed: the heat losses due to thermal conductivity and the estimated daily heating and air-conditioning load curves. By considering daily power consumption curves and weather data for several winter and summer days, the heating/air-conditioning schedule is estimated and the available electrical energy from a microturbine-based cogeneration system is estimated. Simulation results confirm the potential of using cogeneration and trigeneration systems for local distributed electricity generation and grid support in the daily peaks of power consumption.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuels consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
A 400-kWe high-efficiency steam turbine for industrial cogeneration
NASA Technical Reports Server (NTRS)
Leibowitz, H. M.
1982-01-01
An advanced state-of-the-art steam turbine-generator developed to serve as the power conversion subsystem for the Department of Energy's Sandia National Laboratories' Solar Total-Energy Project (STEP) is described. The turbine-generator, which is designed to provide 400-kW of net electrical power, represents the largest turbine-generator built specifically for commercial solar-powered cogeneration. The controls for the turbine-generator incorporate a multiple, partial-arc entry to provide efficient off-design performance, as well as an extraction control scheme to permit extraction flow regulation while maintaining 110-spsig pressure. Normal turbine operation is achieved while synchronized to a local utility and in a stand-alone mode. In both cases, the turbine-generator features automatic load control as well as remote start-up and shutdown capability. Tests totaling 200 hours were conducted to confirm the integrity of the turbine's mechanical structure and control function. Performance tests resulted in a measured inlet throttle flow of 8,450 pounds per hour, which was near design conditions.
77 FR 47049 - Commission Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
... collection FERC-914 (Cogeneration and Small Power Production--Tariff Filings) to the Office of Management and... statement]; (2) ensuring that these facilities are using their thermal output in a productive and beneficial... Annual Burden\\3\\: The Commission estimates the total Public Reporting Burden for this information...
Code of Federal Regulations, 2014 CFR
2014-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2012 CFR
2012-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2014 CFR
2014-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2014 CFR
2014-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2013 CFR
2013-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
78 FR 67354 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-12
.... Description: Simon Solar, LLC submits Supplement Record in Pending Filing to be effective 10/1/2013. Filed.... Applicants: All Dams Generation, LLC, Arlington Valley Solar Energy II, LLC, Bluegrass Generation Company, L.L.C., Calhoun Power Company, LLC, Centinela Solar Energy, LLC, Cherokee County Cogeneration Partners...
Developing the Music Pre-Service Teacher through International Service Learning
ERIC Educational Resources Information Center
Power, Anne
2013-01-01
Service learning in tertiary education is about partnerships between higher education institutions and communities, as co-generators of knowledge. Arts programs in service learning engage what Rendon (2009) calls "sentipensante" (sensing/thinking) pedagogy, in which critical examinations of ways of thinking and doing sit alongside…
76 FR 70715 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... Wind, LLC, Pedricktown Cogeneration Company LP, ReEnergy Sterling CT Limited Partnership, Bayonne Plant.... Applicants: Golden Winds Holding, LLC. Description: Golden Winds Holding, LLC Application for Approval under Section 203 of the Federal Power Act and Request for Expedited Action. Filed Date: 11/04/2011. Accession...
26 CFR 1.141-7 - Special rules for output facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... nameplate capacity or the equivalent (or where there is no nameplate capacity or the equivalent, its maximum capacity), which is not reduced for reserves, maintenance or other unutilized capacity. (ii) Transmission and other output facilities—(A) In general. For transmission, distribution, cogeneration, and other...
26 CFR 1.141-7 - Special rules for output facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... nameplate capacity or the equivalent (or where there is no nameplate capacity or the equivalent, its maximum capacity), which is not reduced for reserves, maintenance or other unutilized capacity. (ii) Transmission and other output facilities—(A) In general. For transmission, distribution, cogeneration, and other...
26 CFR 1.141-7 - Special rules for output facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... nameplate capacity or the equivalent (or where there is no nameplate capacity or the equivalent, its maximum capacity), which is not reduced for reserves, maintenance or other unutilized capacity. (ii) Transmission and other output facilities—(A) In general. For transmission, distribution, cogeneration, and other...
26 CFR 1.141-7 - Special rules for output facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... nameplate capacity or the equivalent (or where there is no nameplate capacity or the equivalent, its maximum capacity), which is not reduced for reserves, maintenance or other unutilized capacity. (ii) Transmission and other output facilities—(A) In general. For transmission, distribution, cogeneration, and other...
26 CFR 1.141-7 - Special rules for output facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... nameplate capacity or the equivalent (or where there is no nameplate capacity or the equivalent, its maximum capacity), which is not reduced for reserves, maintenance or other unutilized capacity. (ii) Transmission and other output facilities—(A) In general. For transmission, distribution, cogeneration, and other...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-11
... electric energy from qualifying cogeneration facilities and qualifying small power production facilities... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission 18 CFR Part 376 [Docket No. RM10-28-000... Activation of Continuity of Operations Plan Issued August 5, 2010. AGENCY: Federal Energy Regulatory...
Peer-Mediated Reading and Writing in a Digital, Multimodal Environment
ERIC Educational Resources Information Center
Fitzgerald, Miranda S.; Palincsar, Annemarie Sullivan
2017-01-01
The goals for engaging students in peer learning range from positioning students as knowledgeable others to promoting social-emotional learning goals to providing contexts in which students can articulate and compare their thinking to supporting opportunities to cogenerate solutions to complex problems. There are a number of complexities…
40 CFR 63.7575 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... having the primary purpose of recovering thermal energy in the form of steam or hot water. Controlled... the energy assessment. Electric utility steam generating unit (EGU) means a fossil fuel-fired... for sale. A fossil fuel-fired unit that cogenerates steam and electricity and supplies more than one...
40 CFR 63.7575 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... having the primary purpose of recovering thermal energy in the form of steam or hot water. Controlled... the energy assessment. Electric utility steam generating unit (EGU) means a fossil fuel-fired... for sale. A fossil fuel-fired unit that cogenerates steam and electricity and supplies more than one...
The report summarizes the key technical results of a joint demonstration project between the U.S. Environmental Protection Agency and the Taiwan Environmental Protection Administration. The project demonstrated that coal reburning can be used to reduce nitrogen oxides (NOX) emiss...
77 FR 71186 - Commission Information Collection Activities (FERC-912); Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-29
... submitting the information collection FERC-912, Cogeneration and Small Power Production, PURPA Section 210(m... Production, PURPA Section 210(m) Regulations for Termination or Reinstatement of Obligation to Purchase or... Section 210 of the Public Utility Regulatory Policies Act of 1978 (PURPA) by adding subsection ``(m...
78 FR 16487 - Commission Information Collection Activities (FERC-556); Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
... Policies Act of 1978 (PURPA).\\1\\ FERC is authorized to encourage cogeneration and small power production... power production facilities which use other wastes and renewable resources. PURPA, encourages the... order to obtain qualifying status; the PURPA benefits which are available to QFs to encourage small...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
... Regulatory Policies Act of 1978 (PURPA).\\1\\ FERC is authorized to encourage cogeneration and small power... power production facilities which use other wastes and renewable resources. PURPA, encourages the... order to obtain qualifying status; The PURPA benefits which are available to QFs to encourage small...
78 FR 43198 - Watson Cogeneration Company; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-19
....214). Protests will be considered by the Commission in determining the appropriate action to be taken... must file a notice of intervention or motion to intervene, as appropriate. Such notices, motions, or... serve motions to intervene or protests on persons other than the Applicant. The Commission encourages...
Energy efficient industrial technology in Europe: A compendium
NASA Astrophysics Data System (ADS)
Fassbender, A. G.; McGee, M. J.
1982-05-01
Energy efficient industrial technologies currently in use in Europe are described. Gas-fired equipment in West Germany, France, and the United Kingdom is emphasized. Some of these technologies are unique and some are currently available in the United States. Load management, cogeneration, heat recovery, and various industrial processes are discussed.
77 FR 1064 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-09
... SCE-TA-High Desert LLC Antelope Power Plant Project to be effective 12/30/2011. Filed Date: 12/29/11... Market Power Analysis of Northern Indiana Public Service Company. Filed Date: 12/28/11. Accession Number..., Duke Energy Indiana, Inc., St. Paul Cogeneration, LLC. Description: Updated market power analysis of...
This presentation will report on work underway to inventory facilities currently utilizing biogas from anaerobic digestion and speak with practitioners to learn: techniques for preparing residuals for digestion, methods to use for cleaning biogas (e.g., of siloxane), and how gas...
Creep of Hi-Nicalon S Ceramic Fiber Tows at Elevated Temperature in Air and in Steam
2012-03-22
temperature and environmental effects is a critical factor in development of composites with load carrying capacity and environmental durability...applications, including aircraft jet engines, gas turbines for electrical power/steam cogeneration , as well as nuclear power plant components. It is
Code of Federal Regulations, 2014 CFR
2014-01-01
... and natural gas savings. Average Annual Utilization of Oil and Natural Gas for Electricity Generation by State [BTU's per KWHR sold] State name Oil/gas savings Btu/kWh Alabama 33 Arizona 802 Arkansas 1... Virginia 126 Wisconsin 72 Wyoming 75 Data are based upon 1987 oil, natural gas and electricity statistics...
Code of Federal Regulations, 2012 CFR
2012-01-01
... and natural gas savings. Average Annual Utilization of Oil and Natural Gas for Electricity Generation by State [BTU's per KWHR sold] State name Oil/gas savings Btu/kWh Alabama 33 Arizona 802 Arkansas 1... Virginia 126 Wisconsin 72 Wyoming 75 Data are based upon 1987 oil, natural gas and electricity statistics...
Code of Federal Regulations, 2011 CFR
2011-01-01
... and natural gas savings. Average Annual Utilization of Oil and Natural Gas for Electricity Generation by State [BTU's per KWHR sold] State name Oil/gas savings Btu/kWh Alabama 33 Arizona 802 Arkansas 1... Virginia 126 Wisconsin 72 Wyoming 75 Data are based upon 1987 oil, natural gas and electricity statistics...
Code of Federal Regulations, 2013 CFR
2013-01-01
... and natural gas savings. Average Annual Utilization of Oil and Natural Gas for Electricity Generation by State [BTU's per KWHR sold] State name Oil/gas savings Btu/kWh Alabama 33 Arizona 802 Arkansas 1... Virginia 126 Wisconsin 72 Wyoming 75 Data are based upon 1987 oil, natural gas and electricity statistics...
2016-12-01
Incinerator with Cogeneration. Source: Taylor (2016). 2. Anaerobic Digestion Anaerobic digestion uses a fermentation process to produce methane from...ANAEROBIC DIGESTION Anaerobic digestion uses a fermentation process to produce methane from organic waste inputs, resulting in a biogas that is then
40 CFR 420.11 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... breeze. (b) The term by-product cokemaking means operations in which coal is heated in the absence of air to produce metallurgical coke (furnace coke and foundry coke), and the recovery of by-products... foundry coke) without recovery of by-products. Does not include co-generation facilities located at non...
77 FR 74652 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-17
...-1521-001; ER12-1522-001; ER12- 1626-001; ER10-2605-004. Applicants: Agua Caliente Solar, LLC, Alta Wind VII, LLC, Alta Wind IX, LLC, Topaz Solar Farms LLC, Yuma Cogeneration Associates. Description...: Midwest Independent Transmission System Operator, Inc. Description: SA 2431 Glacial Ridge Wind-GRE...
The immediate goal is a system based on the integration of the suite of modules developed solar thermal, biogas, ORC, absorption-chiller) that can be assembled together to create systems tailored to the unique demands of individual communities and climates, optimized for effic...
78 FR 44943 - EcoEléctrica, L.P.; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-25
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP13-516-000] EcoEl[eacute... existing liquefied natural gas (LNG) terminal and cogeneration facility site in Pe[ntilde]uelas, Puerto... environmental impact statement (FEIS) or EA for this proposal. The filing of the EA in the Commission's public...
Geothermal Cogeneration: Iceland's Nesjavellir Power Plant
ERIC Educational Resources Information Center
Rosen, Edward M.
2008-01-01
Energy use in Iceland (population 283,000) is higher per capita than in any other country in the world. Some 53.2% of the energy is geothermal, which supplies electricity as well as heated water to swimming pools, fish farms, snow melting, greenhouses, and space heating. The Nesjavellir Power Plant is a major geothermal facility, supplying both…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-16
... facilities. List of Subjects in 18 CFR Part 292 Electric power, Electric power plants, Electric utilities... to Form, Procedures and Criteria for Certification of Qualifying Facility Status for a Small Power... small power production or cogeneration facility. DATES: August 16, 2011. FOR FURTHER INFORMATION CONTACT...
76 FR 65715 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-24
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric rate filings: Docket Numbers: ER10-3246-001; ER11-2044-003; ER11-3876-002; ER10- 2605-001. Applicants: MidAmerican Energy Company, Cordova Energy Company, LLC, PacifiCorp, Yuma Cogeneration...
Code of Federal Regulations, 2013 CFR
2013-07-01
... an unaffected unit under § 72.6(b)(4) of this chapter for 1995 or 1996 under the Acid Rain Program...(b)(4) of this chapter for 1997 or 1998 under the Acid Rain Program. (C) For units commencing... the Acid Rain Program for any year. (2)(i) For units other than cogeneration units— (A) For units...
Code of Federal Regulations, 2014 CFR
2014-07-01
... an unaffected unit under § 72.6(b)(4) of this chapter for 1995 or 1996 under the Acid Rain Program...(b)(4) of this chapter for 1997 or 1998 under the Acid Rain Program. (C) For units commencing... the Acid Rain Program for any year. (2)(i) For units other than cogeneration units— (A) For units...
Code of Federal Regulations, 2011 CFR
2011-07-01
... an unaffected unit under § 72.6(b)(4) of this chapter for 1995 or 1996 under the Acid Rain Program...(b)(4) of this chapter for 1997 or 1998 under the Acid Rain Program. (C) For units commencing... the Acid Rain Program for any year. (2)(i) For units other than cogeneration units— (A) For units...
Code of Federal Regulations, 2012 CFR
2012-07-01
... an unaffected unit under § 72.6(b)(4) of this chapter for 1995 or 1996 under the Acid Rain Program...(b)(4) of this chapter for 1997 or 1998 under the Acid Rain Program. (C) For units commencing... the Acid Rain Program for any year. (2)(i) For units other than cogeneration units— (A) For units...
Code of Federal Regulations, 2010 CFR
2010-07-01
... an unaffected unit under § 72.6(b)(4) of this chapter for 1995 or 1996 under the Acid Rain Program...(b)(4) of this chapter for 1997 or 1998 under the Acid Rain Program. (C) For units commencing... the Acid Rain Program for any year. (2)(i) For units other than cogeneration units— (A) For units...
ERIC Educational Resources Information Center
Siry, Christina A.; Zawatski, Elizabeth
2011-01-01
Using critical ethnography guided by cultural sociology, this paper examines the role of "co" in teacher education; coresearching, coteaching, and cogenerating dialogue. The authors are a pre-service teacher and a college instructor, and through our multiple perspectives and positionings, we explore how collaboration served to dismantle…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-11
... cogeneration and combined cycle modes, currently comprised of combustion turbine, diesel and steam turbine... natural gas and oil based fuels. The facility is interconnected with NSTAR Electric Company, and sells excess electric power output that is not consumed by the facility's institutional and commercial...
Heat exchanger design for hot air ericsson-brayton piston engine
NASA Astrophysics Data System (ADS)
Ďurčanský, P.; Lenhard, R.; Jandačka, J.
2014-03-01
One of the solutions without negative consequences for the increasing energy consumption in the world may be use of alternative energy sources in micro-cogeneration. Currently it is looking for different solutions and there are many possible ways. Cogeneration is known for long time and is widely used. But the installations are often large and the installed output is more suitable for cities or industry companies. When we will speak about decentralization, the small machines have to be used. The article deals with the principle of hot-air engines, their use in combined heat and electricity production from biomass and with heat exchangers as primary energy transforming element. In the article is hot air engine presented as a heat engine that allows the conversion of heat into mechanical energy while heat supply can be external. In the contribution are compared cycles of hot-air engine. Then are compared suitable heat exchangers for use with hot air Ericsson-Brayton engine. In the final part is proposal of heat exchanger for use in closed Ericsson-Brayton cycle.
Cogenerating and pre-annihilating dark matter by a new gauge interaction in a unified model
Barr, S. M.; Scherrer, Robert J.
2016-05-31
Here, grand unified theories based on large groups (with rank ≥ 6) are a natural context for dark matter models. They contain Standard-Model-singlet fermions that could be dark matter candidates, and can contain new non-abelian interactions whose sphalerons convert baryons, leptons, and dark matter into each other, ''cogenerating" a dark matter asymmetry comparable to the baryon asymmetry. In this paper it is shown that the same non-abelian interactions can ''pre-annihilate" the symmetric component of heavy dark matter particles χ, which then decay late into light stable dark matter particles ζ that inherit their asymmetry. We derive cosmological constraints on themore » parameters of such models. The mass of χ must be < 3000 TeV and their decays must happen when 2 × 10 –7 < T dec/mχ < 10 –4. It is shown that such decays can come from d=5 operators with coefficients of order 1/MGUT or 1/M Pℓ. We present a simple realization of our model based on the group SU(7).« less
Bio-mass utilization in high pressure cogeneration boiler
NASA Astrophysics Data System (ADS)
Koundinya, Sandeep; Maria Ambrose Raj, Y.; Sreeram, K.; Divakar Shetty A., S.
2017-07-01
Coal is widely used all over the world in almost all power plants. The dependence on coal has increased enormously as the demand for electricity has reached its peak. Coal being a non-renewable source is depleting fast. We being the engineers, it's our duty to conserve the natural resources and optimize the coal consumption. In this project, we have tried to optimize the bio-mass utilization in high pressure cogeneration boiler. The project was carried in Seshasayee Paper and Boards Limited, erode related to Boiler No:10 operating at steam pressure of 105 kscg and temperature of 510°C. Available bio-mass fuels in and around the mill premises are bagasse, bagasse pith, cane trash and chipper dust. In this project, we have found out the coal equivalent replacement by the above bio-mass fuel(s) to facilitate deciding on the optimized quantity of coal that can be replaced by biomass without modifying the existing design of the plant. The dominant fuel (coal) which could be displaced with the substitute biomass fuel had been individually (biomass) analyzed.
Gas-engine-based, low-emission cogeneration units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chellini, R.
1994-04-01
Continental Energy Systems (CES) of Westmalle, Belgium, has been specializing, since its foundation in 1983, in the supply of cogeneration packages in the 50-300 KW power range. CES activity is mainly concentrated in the transformation of Valmet, Scania, Iveco and MAN diesel engines into spark-ignited engines capable of running on natural gas, CNG, LPG, biogas, landfill gas, etc. In the upper power range they also package Waukesha gas engines supplied from the Dutch plant of the American engine manufacturer. The new closed-loop combustion control system allows engines in the naturally-aspirated or turbocharged configuration with catalytic converters to operate well belowmore » Euro 2 limits. In fact, these engines already comply with 1995 CARB (California Air Resources Board) emission limits and with those that will become mandatory in Europe with the 1996 step. The new system still makes use of conventional components for metering and mixing functions, but these are considered as three separate devices; the electronic control unit, the oxygen sensor and an actuator enabling closed loop air/fuel ratio control. 4 figs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-31
Over the next four years, the Progetto Energia project will be building several cogeneration plants to help satisfy the increasing demands of Italy`s industrial users and the country`s demand for electrical power. Located at six different sites within Italy, these combined-cycle cogeneration plants will supply a total of 500 MW of electricity and 100 tons/hr of process steam to Italian industries and residences. To ensure project success, a dynamic model of the 50-MW base unit was developed. The goal established for the model was to predict the dynamic behavior of the complex thermodynamic system in order to assess equipment performancemore » and control system effectiveness for normal operation and, more importantly, abrupt load changes. In addition to fulfilling its goals, the dynamic study guided modifications to controller logic that significantly improved steam drum pressure control and bypassed steam desuperheating performance simulations of normal and abrupt transient events allowed engineers to define optimum controller gain coefficients. The dynamic study will undoubtedly reduce the associated plant start-up costs and contribute to a smooth commercial plant acceptance. As a result of the work, the control system has already been through its check-out and performance evaluation, usually performed during the plant start-up phase. Field engineers will directly benefit from this effort to identify and resolve control system {open_quotes}bugs{close_quotes} before the equipment reaches the field. High thermal efficiency, rapid dispatch and high plant availability were key reasons why the natural gas combined-cycle plant was chosen. Other favorable attributes of the combined-cycle plant contributing to the decision were: Minimal environmental impact; a simple and effective process and control philosophy to result in safe and easy plant operation; a choice of technologies and equipment proven in a large number of applications.« less
Simulation model of stratified thermal energy storage tank using finite difference method
NASA Astrophysics Data System (ADS)
Waluyo, Joko
2016-06-01
Stratified TES tank is normally used in the cogeneration plant. The stratified TES tanks are simple, low cost, and equal or superior in thermal performance. The advantage of TES tank is that it enables shifting of energy usage from off-peak demand for on-peak demand requirement. To increase energy utilization in a stratified TES tank, it is required to build a simulation model which capable to simulate the charging phenomenon in the stratified TES tank precisely. This paper is aimed to develop a novel model in addressing the aforementioned problem. The model incorporated chiller into the charging of stratified TES tank system in a closed system. The model was developed in one-dimensional type involve with heat transfer aspect. The model covers the main factors affect to degradation of temperature distribution namely conduction through the tank wall, conduction between cool and warm water, mixing effect on the initial flow of the charging as well as heat loss to surrounding. The simulation model is developed based on finite difference method utilizing buffer concept theory and solved in explicit method. Validation of the simulation model is carried out using observed data obtained from operating stratified TES tank in cogeneration plant. The temperature distribution of the model capable of representing S-curve pattern as well as simulating decreased charging temperature after reaching full condition. The coefficient of determination values between the observed data and model obtained higher than 0.88. Meaning that the model has capability in simulating the charging phenomenon in the stratified TES tank. The model is not only capable of generating temperature distribution but also can be enhanced for representing transient condition during the charging of stratified TES tank. This successful model can be addressed for solving the limitation temperature occurs in charging of the stratified TES tank with the absorption chiller. Further, the stratified TES tank can be charged with the cooling energy of absorption chiller that utilizes from waste heat from gas turbine of the cogeneration plant.
78 FR 31916 - Yuma Cogeneration Associates; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-28
... protest this filing must file in accordance with Rules 211 and 214 of the Commission's Rules of Practice.... Any person wishing to become a party must file a notice of intervention or motion to intervene, as... Internet access who will eFile a document and/or be listed as a contact for an intervenor must create and...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
18 CFR 292.205 - Criteria for qualifying cogeneration facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... useful thermal energy output of the facility must be no less than 5 percent of the total energy output... the facility plus one-half the useful thermal energy output, during the 12-month period beginning with... (B) If the useful thermal energy output is less than 15 percent of the total energy output of the...
76 FR 44900 - Notice of Effectiveness of Exempt Wholesale; Generator Status
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-27
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Effectiveness of Exempt Wholesale; Generator Status July 13, 2011. Yuba City Cogeneration Docket Nos. EG11-74-000 Partners, LP. Dempsey Ridge Wind Farm, LLC. EG11-75-000 Howard Wind LLC EG11-76-000 Highland North LLC EG11-77-000 KES...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Georgia 45 Idaho 0 Illinois 250 Indiana 53 Iowa 147 Kansas 686 Kentucky 34 Louisiana 4,189 Maine 2,560... Nebraska 139 Nevada 761 New Hampshire 2,695 New Jersey 1,894 New Mexico 1,528 New York 4,219 North Carolina 49 North Dakota 47 Ohio 36 Oklahoma 5,180 Oregon 0 Pennsylvania 771 Rhode Island 1,800 South Carolina...
1985-04-02
sothat oilconsumptior ASME Boiler and Pressure Vessel Code . can be measured. Hot water boiler plants with out- U1I Shell-and-tube type exchangers are...slopes possible to VIII of the ASME Boiler and Pressure Vessel Code . prevent rain or melting snow from penetrating into (2? Water will flow through the
ERIC Educational Resources Information Center
Seakins, Amy; Dillon, Justin
2013-01-01
The primacy of the research question in designing studies affords an opportunity for enhancing collaborations between researchers and "practitioners". This paper describes the use of a modified Delphi technique to co-generate research questions for a collaborative research study co-funded by a university and a natural history museum.…
USDA-ARS?s Scientific Manuscript database
Biochar (BC) is a product of thermochemical conversion of biomass via pyrolysis, together with gas (syngas), liquid (bio-oil), and heat. Fast pyrolysis is a promising process for bio-oil generation, which leaves 10-30% of the original biomass as char. When applied to soils, BC may increase soil C s...
User Data Package (UDP) for Packaged Cogeneration Systems (PCS)
1990-05-01
Standards for PURPA Compliance ............ ...................... 10 1.3 Selected Commercial, Institutional, and Multi-unit Technically Feasible...percent. The Federal Energy Regulatory Commission (FERC), in accordance with Section 201 of the Public Utility Regulatory Policies Act ( PURPA ) of 1978...percent of the time the engine was running, or if 57 percent of the recovered engine heat were stored. Additional requirements for PURPA efficiency that
NASA Astrophysics Data System (ADS)
1980-10-01
Specifications are given for the shipping, marking, inspection, testing, and start up of equipment to be used in a proposed wood fuel cogeneration system in Maine. Couplings, mechanical drives, electric motors, spare parts, coatings, assembling, and materials handling and packaging are covered. Both OSHA and noise control regulations are included along with the ASME code.
System for the co-production of electricity and hydrogen
Pham, Ai Quoc; Anderson, Brian Lee
2007-10-02
Described herein is a system for the co-generation of hydrogen gas and electricity, wherein the proportion of hydrogen to electricity can be adjusted from 0% to 100%. The system integrates fuel cell technology for power generation with fuel-assisted steam-electrolysis. A hydrocarbon fuel, a reformed hydrocarbon fuel, or a partially reformed hydrocarbon fuel can be fed into the system.
The dynamic simulation of the Progetto Energia combined cycle power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giglio, R.; Cerabolini, M.; Pisacane, F.
1996-12-31
Over the next four years, the Progetto Energia project is building several cogeneration plants to satisfy the increasing demands of Italy`s industrial complex and the country`s demand for electrical power. Located at six different sites within Italy`s borders these Combined Cycle Cogeneration Plants will supply a total of 500 MW of electricity and 100 tons/hr of process steam to Italian industries and residences. To ensure project success, a dynamic model of the 50 MW base unit was developed. The goal established for the model was to predict the dynamic behavior of the complex thermodynamic system in order to assess equipmentmore » performance and control system effectiveness for normal operation and, more importantly, abrupt load changes. In addition to fulfilling its goals, the dynamic study guided modifications to controller logic that significantly improved steam drum pressure control and bypassed steam de-superheating performance. Simulations of normal and abrupt transient events allowed engineers to define optimum controller gain coefficients. The paper discusses the Combined Cycle plant configuration, its operating modes and control system, the dynamic model representation, the simulation results and project benefits.« less
Preliminary design studies on a nuclear seawater desalination system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wibisono, A. F.; Jung, Y. H.; Choi, J.
2012-07-01
Seawater desalination is one of the most promising technologies to provide fresh water especially in the arid region. The most used technology in seawater desalination are thermal desalination (MSF and MED) and membrane desalination (RO). Some developments have been done in the area of coupling the desalination plant with a nuclear reactor to reduce the cost of energy required in thermal desalination. The coupling a nuclear reactor to a desalination plant can be done either by using the co-generation or by using dedicated heat from a nuclear system. The comparison of the co-generation nuclear reactor with desalination plant, dedicated nuclearmore » heat system, and fossil fueled system will be discussed in this paper using economical assessment with IAEA DEEP software. A newly designed nuclear system dedicated for the seawater desalination will also be suggested by KAIST (Korea Advanced Inst. of Science and Technology) research team and described in detail within this paper. The suggested reactor system is using gas cooled type reactor and in this preliminary study the scope of design will be limited to comparison of two cases in different operating temperature ranges. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carney, M.V.
The Logan Generating Plant is a $500 million, 202-megawatt (MW), pulverized-coal cogeneration facility. Its electricity output - enough for 270,000 homes - is sold to Atlantic Electric. It also supplies all of the steam (up to 50,000 pounds per hour) to a nearby Monsanto facility. The plant went into commercial service in September 1994. Currently, the facility employs 62 people. In addition to becoming an active, long-term employer in Logan Township, the plant will help stimulate the local economy for years to come as a consumer of goods and services. In addition, local and state revenues from the Logan plantmore » provide a much needed economic boost. Cogeneration, which is the production of electric power and thermal energy (heat) from a single energy source, provides efficiency benefits in fuel consumption, capital investment and operating costs. Electricity and process steam from the Logan plant helps Monsanto control its energy costs, thus helping it remain competitive. The Logan Generating Plant plays an important role in the economic development of southern New Jersey by providing clean, dependable and competitively priced electricity to Atlantic Electric for resale to its utility customers. The environmental and economic benefits of the facility are discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCollom, M.
1979-01-01
A comprehensive review of a wide range of alternatives to the proposed action, the commercial demonstration of an industrial cogenerating facility fired with wood fuels is provided. An extensive effort has been devoted to the evaluation of all reasonable alternatives to this project. A number of possible actions were also briefly considered, but, for various reasons, they were found not to be appropriate at present for a commercial-scale demonstration of an alternative energy source. The critical characteristics of the wood-fueled commercial demonstration project at Westbrook are considered to be: industrial cogeneration of power; the production of 510,000 pounds per hourmore » of industrial process steam; the production of approximately twenty-five megawatts of electric generating capacity, some of which would be available to a public utility in southern Maine; and the consumption of 2,000 tons of wood fuel per day. Each of the alternatives examined in this appendix offers a different option for one or several of the characteristics of the project listed above. As a whole, the appendix describes the range of possible actions that the US Department of Energy and its contractors have considered.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mariano, García; Daniel, Prats; Arturo, Trapote, E-mail: atj@ua.es
2015-12-21
The siloxanes present in the biogas produced during anaerobic digestion damage the mechanism of cogeneration equipment and, consequently, negatively affect the energy valorization process. For this reason, the detection and elimination of these silicon-derived chemical compounds are a priority in the management of cogeneration facilities. In this regard, the objectives of this paper are, firstly, to characterize the siloxanes in the biogas and, secondly, to qualitatively evaluate the influence of the dose of iron chloride on its elimination. The research was performed at the Rincón de León Wastewater Treatment Plant (Alicante, Spain). The outflow biogas of the digesters and ofmore » the pressurized gasometers was sampled and analyzed. The results obtained made it possible to demonstrate, firstly, the absence of linear siloxanes and that, of the cyclic siloxanes, the predominant type was decamethylcyclopentasiloxane, and, secondly, that the addition of iron chloride in the digesters significantly reduces the siloxane content in the biogas. Additionally, it was demonstrated that the process of compression of the biogas, with the elimination of condensates, also produces significant reductions in the concentration of siloxanes in the biogas.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, J.A.
1989-01-01
The one year internship required for partial fulfillment of the Doctor of Engineering Degree was completed at the Governor's Energy Management Center in Austin, Texas. The intern worked for the State Agencies Department of the Energy Management Center. The intern was involved in a variety of projects, but the primary projects requiring the greatest time were the involvement with the design reviews for energy efficiency of new prisons being constructed in Texas, conducting energy management audits at 18 major state universities, and the technical and administrative assistance to the State Cogeneration Council. Other project involvement included managing the preliminary engineeringmore » design of the cogeneration facility at Austin State Hospital, responsibility for applying for a $1.4 million dollar crude oil refund on the behalf of all state agencies in Texas, and assisting in the planning and coordination of the $48 million Revolving Loan Program for the state of Texas. The internship taught many things about management and communications. The experience also provided a better understanding of how the state and federal government operate. The greatest contribution of the internship experience was the improvement of the intern's written and oral communication skills.« less
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
Various advanced energy conversion systems (ECS) are compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidates which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on-site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented for coal fired process boilers. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented.
NASA Astrophysics Data System (ADS)
Kato, Takeyoshi; Minagata, Atsushi; Suzuoki, Yasuo
This paper discusses the influence of mass installation of a home co-generation system (H-CGS) using a polymer electrolyte fuel cell (PEFC) on the voltage profile of power distribution system in residential area. The influence of H-CGS is compared with that of photovoltaic power generation systems (PV systems). The operation pattern of H-CGS is assumed based on the electricity and hot-water demand observed in 10 households for a year. The main results are as follows. With the clustered H-CGS, the voltage of each bus is higher by about 1-3% compared with the conventional system without any distributed generators. Because H-CGS tends to increase the output during the early evening, H-CGS contributes to recover the voltage drop during the early evening, resulting in smaller voltage variation of distribution system throughout a day. Because of small rated power output about 1kW, the influence on voltage profile by the clustered H-CGS is smaller than that by the clustered PV systems. The highest voltage during the day time is not so high as compared with the distribution system with the clustered PV systems, even if the reverse power flow from H-CGS is allowed.
ABB's advanced steam turbine program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chellini, R.
Demand for industrial steam turbines for combined-cycle applications and cogeneration plants has influenced turbine manufacturers to standardize their machines to reduce delivery time and cost. ABB, also a supplier of turnkey plants, manufactures steam turbines in Finspong, Sweden, at the former ASEA Stal facilities and in Nuernberg, Germany, at the former AEG facilities. The companies have joined forces, setting up the advanced Steam Turbine Program (ATP) that, once completed, will cover a power range from two to 100 MW. The company decided to use two criteria as a starting point, the high efficiency design of the Swedish turbines and themore » high reliability of the German machines. Thus, the main task was combining the two designs in standard machines that could be assembled quickly into predefined packages to meet specific needs of combined-cycle and cogeneration plants specified by customers. In carrying out this project, emphasis was put on cost reduction as one of the main goals. The first results of the ATP program, presented by ABB Turbinen Nuernberg, is the range of 2-30 MW turbines covered by two frame sizes comprising standard components supporting the thermodynamic module. An important feature is the standardization of the speed reduction gearbox.« less
Computational tool for simulation of power and refrigeration cycles
NASA Astrophysics Data System (ADS)
Córdoba Tuta, E.; Reyes Orozco, M.
2016-07-01
Small improvement in thermal efficiency of power cycles brings huge cost savings in the production of electricity, for that reason have a tool for simulation of power cycles allows modeling the optimal changes for a best performance. There is also a big boom in research Organic Rankine Cycle (ORC), which aims to get electricity at low power through cogeneration, in which the working fluid is usually a refrigerant. A tool to design the elements of an ORC cycle and the selection of the working fluid would be helpful, because sources of heat from cogeneration are very different and in each case would be a custom design. In this work the development of a multiplatform software for the simulation of power cycles and refrigeration, which was implemented in the C ++ language and includes a graphical interface which was developed using multiplatform environment Qt and runs on operating systems Windows and Linux. The tool allows the design of custom power cycles, selection the type of fluid (thermodynamic properties are calculated through CoolProp library), calculate the plant efficiency, identify the fractions of flow in each branch and finally generates a report very educational in pdf format via the LaTeX tool.
Cogeneration Technology Alternatives Study (CTAS). Volume 3: Industrial processes
NASA Technical Reports Server (NTRS)
Palmer, W. B.; Gerlaugh, H. E.; Priestley, R. R.
1980-01-01
Cogenerating electric power and process heat in single energy conversion systems rather than separately in utility plants and in process boilers is examined in terms of cost savings. The use of various advanced energy conversion systems are examined and compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the target energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. An attempt was made to use consistent assumptions and a consistent set of ground rules specified by NASA for determining performance and cost. Data and narrative descriptions of the industrial processes are given.
All-regime combined-cycle plant: Engineering solutions
NASA Astrophysics Data System (ADS)
Berezinets, P. A.; Tumanovskii, G. G.; Tereshina, G. E.; Krylova, I. N.; Markina, V. N.; Migun, E. N.
2016-12-01
The development of distributed power generation systems as a supplement to the centralized unified power grid increases the operational stability and efficiency of the entire power generation industry and improves the power supply to consumers. An all-regime cogeneration combined-cycle plant with a power of 20-25 mW (PGU-20/25T) and an electrical efficiency above 50% has been developed at the All-Russia Thermal Engineering Institute (ATEI) as a distributed power generation object. The PGU-20/25T two-circuit cogeneration plant provides a wide electrical and thermal power adjustment range and the absence of the mutual effect of electrical and thermal power output regimes at controlled frequency and power in a unified or isolated grid. The PGU-20/25T combined-cycle plant incorporates a gas-turbine unit (GTU) with a power of 16 MW, a heat recovery boiler (HRB) with two burners (before the boiler and the last heating stage), and a cogeneration steam turbine with a power of 6/9 MW. The PGU-20/25T plant has a maximum electrical power of 22 MW and an efficiency of 50.8% in the heat recovery regime and a maximum thermal power output of 16.3 MW (14 Gcal/h) in the cogeneration regime. The use of burners can increase the electrical power to 25 MW in the steam condensation regime at an efficiency of 49% and the maximum thermal power output to 29.5 MW (25.4 Gcal/h). When the steam turbine is shut down, the thermal power output can grow to 32.6 MW (28 Gcal/h). The innovative equipment, which was specially developed for PGU-20/25T, improves the reliability of this plant and simplifies its operation. Among this equipment are microflame burners in the heat recovery boiler, a vacuum system based on liquid-ring pumps, and a vacuum deaerator. To enable the application of PGU-20/25T in water-stressed regions, an air condenser preventing the heat-transfer tubes from the risk of covering with ice during operation in frost air has been developed. The vacuum system eliminates the need for an extraneous source of steam for the startup of the PGU-20/25T plant. The vacuum deaerator provides prestartup deaeration and the filling of the entire condensate feed pipeline with deaerated water and also enables the maintenance of the water temperature before the boiler at a level of no lower than 60°C and the oxygen content at a level of no higher than 10 μg/L during operation under load. The microflame burners in the heat recovery boiler enable the independent adjustment of the electrical power and the thermal power output from the PGU-20/25T plant. All the innovative equipment has been tested on experimental prototypes.
Defense Energy Support Center Fact Book FY 2007
2008-03-21
3 M 21 years Fort Monmouth, NJ Lighting Upgrade, HVAC Renovation , UESC Implementation, GHP, Cogeneration System Site Preparation/Feasibility Ameresco...behalf of Navy Installations in the Sicily, Sardinia and Campania regions of Italy . Awards were made to two companies, ENEL Energia and Energia y...funded $333 million for SRM projects to maintain and renovate military Services owned fuels facilities worldwide . This amount was nearly double the
Potential availability of diesel waste heat at Echo Deep Space Station (DSS 12)
NASA Technical Reports Server (NTRS)
Hughes, R. D.
1982-01-01
Energy consumption at the Goldstone Echo Deep Space Station (DSS 12) is predicted and quantified for a future station configuration which will involve implementation of proposed energy conservation modifications. Cogeneration by the utilization of diesel waste-heat to satisfy site heating and cooling requirements of the station is discussed. Scenarios involving expanded use of on-site diesel generators are presented.
Study of a Wind Energy Conversion System in New Hampshire.
1981-08-01
Federal Jurisdiction Prior to PURPA ........ . 91 2) State Jurisdiction Prior to PURPA .... ....... 93 3) The Contemplated Effect of PURPA on the FERC’s...Jurisdictional Powers ..... ...... 94 (a) Definitions and Concepts of PURPA ... .. 95 (b) Analysis of Wheeling and Interconnection . 96 (i) FPA 9 210...Regarding Certain Interconnection and Wheeling ...... .. ........ 97 (c) PURPA § 210, Cogeneration and Small Power Production ...... ... ... .. 98 b
User Data Package (UDP) for Packaged Cogeneration Systems (PCS)
1990-05-01
4 1.2 Operating Efficiency Standards for PURPA Compliance ......... ..................... 10 1.3 Selected Commercial, Institutional, and Multi...or 81 percent. The Federal Energy Regulatory Commission (FERC), in accordance with Section 201 of the Public Utility Regulatory Policies Act ( PURPA ...least 57 percent of the time the engine was running, or if 57 percent of the recovered engine heat were stored. Additional requirements for PURPA
Electric Power: Contemporary Issues and the Federal Role in Oversight and Regulation.
1981-12-21
Regulatory Commission NRECA National Rural Electric Cooperative Asso- ciation PURPA Public Utility Regulatory Policies Act of 1978 REA Rural...energy efficiency standards for certain products and processes, and sets standards for solar energy and conservation in Federal buildings. PURPA --the...conservation, efficient use of facilities and resources, and equitable rates to electric consumers. PURPA also (1) encourages the use of cogeneration and
Distributed Power Systems for Sustainable Energy
2012-10-01
capital investment in state-of- the-art cogeneration technologies, renewable sources, energy storage, and interconnection hardware and software. It is...8 capacity may not be well suited to support building or campus-scale microgrids. This is because new thermal and electrical energy storage devices...constraints, as well as the site location, weather, and consumption patterns. These factors change over the life of the energy microgrid. • Tradeoffs
2010-03-22
formaldehyde, acetaldehyde, methanol and other HAP from lean bum engines (Included in Addendum F). TABLE 2 Cogeneration Emission Factors ...material which includes recycling of material where feasible. Local landfills have the capacity to accept the amount of waste generated. The contractor...past, present, and reasonably foreseeable future actions. Cumulative impacts can result from individually minor but collectively significant factors
Athanassiou, Christos G; Kavallieratos, Nickolas G; Campbell, James F
2017-04-01
In trapping programs prior capture of individuals of the same or different species may influence subsequent attractiveness of the trap. To evaluate this process with stored-product insects, the effect of the presence of dead or alive adults in traps on the behavioral responses of six stored-product insect species, Tribolium confusum Jacquelin du Val, T. castaneum (Herbst) (Coleoptera: Tenebrionidae), Sitophilus oryzae (L.), S. granarius (L.) (Coleoptera: Curculionidae), Oryzaephilus surinamensis (L.) and O. mercator (Fauvel) (Coleoptera: Silvanidae), was studied in choice tests under laboratory conditions. Two series of tests were carried out. In the first series, the choice was between either alive or dead adults of same species and blank (no adults). Overall, dead adults had the strongest influence, increasing the response of S. oryzae, S. granarius, O. surinamensis, and O. mercator and decreasing the response of the two Tribolium species. Presence of alive adults generally did not result in a response different from blank, except for T. castaneum and O. surinamensis that had a reduced response. In the second series of tests, the choice was between alive or dead individuals of the species vs. alive or dead individuals of its relative cogeneric species. For choices between alive individuals, S. oryzae, S. granarius, and O. surinamensis showed a preference for alive individuals of the same species vs. the cogeneric species, and for all the other species there was no preference. For choices between dead individuals, T. castaneum exhibited a preference for individuals of the same species, while S. oryzae, S. granarius, and O. mercator showed a preference for individuals of the cogeneric species, and all other combinations did exhibit a preference. Our results suggest that traps containing alive and dead individuals of the same and other species can seriously affect the response and capture of additional insects. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Treating nahcolite containing formations and saline zones
Vinegar, Harold J
2013-06-11
A method for treating a nahcolite containing subsurface formation includes removing water from a saline zone in or near the formation. The removed water is heated using a steam and electricity cogeneration facility. The heated water is provided to the nahcolite containing formation. A fluid is produced from the nahcolite containing formation. The fluid includes at least some dissolved nahcolite. At least some of the fluid is provided to the saline zone.
Meeting the Energy-Climate Challenge
2010-04-21
e.g., cogeneration , wind, some biofuels incl waste-to- energy . • The “win-win” approaches will not be enough. Adequate mitigation will...Meeting the Energy ‐Climate Challenge John P. Holdren Science and Technology Advisor to President Obama and Director...DATE 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Meeting the Energy -Climate Challenge 5a. CONTRACT
Evaluation of Improvements to Brayton Cycle Performance.
1986-05-29
cogeneration systems. They are International Power Technology (IPT), Palo Alto, California and Mechanical Technology, Inc. (MTI), Latham, New York [13]. IPT...constant (10) For a constant Reynold’s number and dimensions, the friction factor will be constant. The relationship for friction of internal ...equation for the friction factor of internal turbulent flow is expressed as Ap -friction =f(Re) - constant. (12) pV 2 Applying Equation (11), Equation (12
1980-06-01
43 3000 TYPICAL MID-1978 COSTS, all overhead included 2000- Type of System: Double alkali flue gas desulfurization plus baghouse particulate removal...Figures 5, 6, and 8 also provide cost estimating data for oil- and natural gas -fired steam turbine systems. Figure 5 shows the steam- generating station of...to the ownership and operation of the system. For systems burning oil or natural gas , fuel will typically constitute 65-90% of the total life cycle
Proceedings: Second Annual Pacific Northwest Alternative and Renewable Energy Resources Conference.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1980-01-01
Papers presented at the conference are published in this volume. The purpose of the conference was to solicit regional cooperation in the promoting of near-term development of such alternative and renewable energy resources in the Pacific Northwest as: cogeneration; biomass; wind; small hydro; solar end-use applications; and geothermal direct heat utilization. Separate abstracts of selected papers were prepared for inclusion in the Energy Data Base.
Creep of Hi-Nicalon S Fiber Tows at Elevated Temperature in Air and in Steam
2013-03-01
materials”[28]. Materials have always been a limiting factor in the advancements of technology. The ever increasing demand for aerospace vehicles that are...matrix composites are designed to have load-carrying capacity at high temperatures in extreme environments. Ceramic matrix composites are prime...engines, gas turbines for electrical power/steam cogeneration , as well as nuclear power plant components. It is recognized that the structural
Power generating system and method utilizing hydropyrolysis
Tolman, R.
1986-12-30
A vapor transmission cycle is described which burns a slurry of coal and water with some of the air from the gas turbine compressor, cools and cleans the resulting low-Btu fuel gas, burns the clean fuel gas with the remaining air from the compressor, and extracts the available energy in the gas turbine. The cycle lends itself to combined-cycle cogeneration for the production of steam, absorption cooling, and electric power.
Cogeneration Technology Alternatives Study (CTAS). Volume 1: Summary report
NASA Technical Reports Server (NTRS)
Gerlaugh, H. E.; Hall, E. W.; Brown, D. H.; Priestley, R. R.; Knightly, W. F.
1980-01-01
Large savings can be made in industry by cogenerating electric power and process heat in single energy conversion systems rather than separately in utility plants and in process boilers. About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidates which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed-cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum-based residual and distillate liquid fuels, and low Btu gas obtained through the on-site gasification of coal. An attempt was made to use consistent assumptions and a consistent set of ground rules for determining performance and cost in individual plants and on a national level. It was found that: (1) atmospheric and pressurized fluidized bed steam turbine systems were the most attractive of the direct coal-fired systems; and (2) open-cycle gas turbines with heat recovery steam generators and combined-cycles with NO(x) emission reduction and moderately increased firing temperatures were the most attractive of the coal-derived liquid-fired systems.
Electricity Cogenerator from Hydrogen and Biogas
NASA Astrophysics Data System (ADS)
Pinate, W.; Chinnasa, P.; Dangphonthong, D.
2017-09-01
This research studied about electricity cogenerator from Hydrogen and Biogas and the factors that cause that effecting Hydrogen from Aluminium which was a cylindrical feature. By using a catalyst was NaOH and CaO, it was reacted in distilled water with percentage of Aluminium: the catalyst (NaOH and CaO) and brought to mix with Biogas afterwards, that have been led to electricity from generator 1 kilowatt. The research outcomes were concentration of solutions that caused amount and percent of maximum Hydrogen was to at 10 % wt and 64.73 % which rate of flowing of constant gas 0.56 litter/minute as temperature 97 degree Celsius. After that led Hydrogen was mixed by Biogas next, conducted to electricity from generator and levelled the voltage of generator at 220 Volt. There after the measure of electricity current and found electricity charge would be constant at 3.1 Ampere. And rate of Biogas flowing and Hydrogen, the result was the generator used Biogas rate of flowing was highest 9 litter/minute and the lowest 7.5 litter/minute, which had rate of flowing around 8.2 litter/minute. Total Biogas was used around 493.2 litter or about 0.493 m3 and Hydrogen had rate of flowing was highest 2.5 litter/minute.
Thermally-enhanced oil recovery method and apparatus
Stahl, Charles R.; Gibson, Michael A.; Knudsen, Christian W.
1987-01-01
A thermally-enhanced oil recovery method and apparatus for exploiting deep well reservoirs utilizes electric downhole steam generators to provide supplemental heat to generate high quality steam from hot pressurized water which is heated at the surface. A downhole electric heater placed within a well bore for local heating of the pressurized liquid water into steam is powered by electricity from the above-ground gas turbine-driven electric generators fueled by any clean fuel such as natural gas, distillate or some crude oils, or may come from the field being stimulated. Heat recovered from the turbine exhaust is used to provide the hot pressurized water. Electrical power may be cogenerated and sold to an electric utility to provide immediate cash flow and improved economics. During the cogeneration period (no electrical power to some or all of the downhole units), the oil field can continue to be stimulated by injecting hot pressurized water, which will flash into lower quality steam at reservoir conditions. The heater includes electrical heating elements supplied with three-phase alternating current or direct current. The injection fluid flows through the heater elements to generate high quality steam to exit at the bottom of the heater assembly into the reservoir. The injection tube is closed at the bottom and has radial orifices for expanding the injection fluid to reservoir pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raflo, D.
1994-07-01
Allison has been on its own since December 1, when General Motors Corporation sold its former Allison Gas Turbine Division to Clayton, Dubilier & Rice Inc, a private New York investment firm, and a group of senior Allison managers for $318 million. Allison engine Company`s current product line includes large engines, small aircraft engines, and industrial engines. Over 140,000 engines have been produced since 1915, giving Allison a large stake in world leaderhsip. With strong cogeneration markets already established in Europe and Japan, Allison`s industrial engines are being positioned to compete in emerging markets in China, Indonesia and the Sovietmore » Union. Cogeneration market potential in the US improves despite the current popularity with abundant, low-cost natural gas because of the South Coast Air Control Management District`s push for reduced emissions. The new 7000-shp KB7 industrial engine is the latest addition to the 501K engine family, and adds increased power (by 1700 shp), with a boost compressor to the current core compressor increasing air flow, along with a new low-loss exhaust system. Allison`s new AE series of turboprop (AE 2100) and turbofan (AE 3007) engines, with engine cores derived from the T406 design, have been selected to power regional airliners. 2 figs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Lisa; Lekov, Alex; McKane, Aimee
2010-08-20
This case study enhances the understanding of open automated demand response opportunities in municipal wastewater treatment facilities. The report summarizes the findings of a 100 day submetering project at the San Luis Rey Wastewater Treatment Plant, a municipal wastewater treatment facility in Oceanside, California. The report reveals that key energy-intensive equipment such as pumps and centrifuges can be targeted for large load reductions. Demand response tests on the effluent pumps resulted a 300 kW load reduction and tests on centrifuges resulted in a 40 kW load reduction. Although tests on the facility?s blowers resulted in peak period load reductions ofmore » 78 kW sharp, short-lived increases in the turbidity of the wastewater effluent were experienced within 24 hours of the test. The results of these tests, which were conducted on blowers without variable speed drive capability, would not be acceptable and warrant further study. This study finds that wastewater treatment facilities have significant open automated demand response potential. However, limiting factors to implementing demand response are the reaction of effluent turbidity to reduced aeration load, along with the cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities.« less
NASA Technical Reports Server (NTRS)
1980-01-01
Six current and thirty-six advanced energy conversion systems were defined and combined with appropriate balance of plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a frame work for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Fuel energy savings of 10 to 25 percent were predicted compared to traditional on site furnaces and utility electricity. With the variety of industrial requirements, each advanced technology had attractive applications. Fuel cells indicated the greatest fuel energy savings and emission reductions. Gas turbines and combined cycles indicated high overall annual savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal derived fuels, or coal with advanced fluid bed combustion or on site gasifications. Data and information for both current and advanced energy conversion technology are presented. Schematic and physical descriptions, performance data, equipment cost estimates, and predicted emissions are included. Technical developments which are needed to achieve commercialization in the 1985-2000 period are identified.
Life-Cycle Evaluation of Domestic Energy Systems
NASA Astrophysics Data System (ADS)
Bando, Shigeru; Hihara, Eiji
Among the growing number of environmental issues, the global warming due to the increasing emission of greenhouse gases, such as carbon dioxide CO2, is the most serious one. In order to reduce CO2 emissions in energy use, it is necessary to reduce primary energy consumption, and to replace energy sources with alternatives that emit less CO2.One option of such ideas is to replace fossil gas for water heating with electricity generated by nuclear power, hydraulic power, and other methods with low CO2 emission. It is also important to use energy efficiently and to reduce waste heat. Co-generation system is one of the applications to be able to use waste heat from a generator as much as possible. The CO2 heat pump water heaters, the polymer electrolyte fuel cells, and the micro gas turbines have high potential for domestic energy systems. In the present study, the life-cycle cost, the life-cycle consumption of primary energy and the life-cycle emission of CO2 of these domestic energy systems are compare. The result shows that the CO2 heat pump water heaters have an ability to reduce CO2 emission by 10%, and the co-generation systems also have another ability to reduce primary energy consumption by 20%.
Load research manual. Volume 3: Load research for advanced technologies
NASA Astrophysics Data System (ADS)
1980-11-01
Technical guidelines for electric utility load research are presented. Special attention is given to issues raised by the load reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. Special load research procedures are presented for solar, wind, and cogeneration technologies.
Analysis of Operational Data: A Proof of Concept for Assessing Electrical Infrastructure Impact
2015-11-01
cogeneration, solar, wind , geothermal, etc.) or by prime mover (i.e., steam turbine , water turbine , gas turbine , etc.). Power plants are typically...and Time SDR Sensor Data Record TRADOC U.S. Army Training and Doctrine Command UTC Coordinated Universal Time VCM VIIRS Cloud Mask VIIRS Visible...power, and other natural sources (water or wind ). The generating facilities or power plants can run by fuel (e.g., fossil fuel, hydroelectric, nuclear
Megawatt Fuel Cell Systems Analysis.
1983-02-01
conversion process must be removed from the system. This heat can be rejected to air or water or recovered for cogeneration applications. The possible...powerplants are significantly lower than existing standards (Figure 2-2). External water is not required for fuel processing or powerplant cooling; only fuel...and air need to be available at the powerplant site. This lack oY’ reliance on external water supply is valuable in areas where water is scarce or
Roll-on perfume compositions containing polyoxybutylene-polyoxyethylene copolymers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmolka, I.R.
1987-05-26
This patent describes a liquid roll-on composition containing, in weight percent based upon the total composition weight, from 5 percent to 15 percent of a perfume oil, from 25 percent to 40 percent of a volatile alcohol, from 10 percent to 60 percent water, and from 10 percent to 30 percent of a nonionic polyether surfactant. The improvement comprises employing as the nonionic polyether surfactant a cogeneric polyoxybutylene-polyoxyethylene block copolymer.
2007-03-01
was calculated using 60 sequential ( ) ’Y t s . 9 As shown by the shaded boxes in Table 2, the price of crude oil was more volatile than the price of...producing liquid fuels alone. [Bajura] Modern plant designs often include a cogeneration lineup that is designed to resell excess electricity to the
Department of Defense Strategic Sustainability Performance Plan
2010-08-26
Evaluating and Prioritizing the Use of Resources A. Evaluating Return on Investment B. Factors in Acquisition and Procurement Decisions C... capacity . Convoy of Fuel and Other Supplies, Afghanistan • A final challenge is grid vulnerability. DoD’s reliance on a fragile commercial grid to...10 percent of the energy consumed by the Department came from renewable sources when thermal sources were included, such as cogeneration and
2011-06-23
contract; information required to be in the offeror’s proposal; and factors and significant subfactors, and their relative importance, which will...development and testing, alternative fuels, alternative fuel sources, and small-scale cogeneration . 1. On-Board Vehicle Power The purpose of the On...savings of 20 percent, greater heating and cooling capacity , and provision of full 30 kilowatts of electrical power output in all environments
OIT Times Newsletter: Volume 3, Number 1, Winter 2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sousa, L.
The Winter 2000 edition of the OIT Times newsletter, a quarterly publication produced by the Office of Industrial Technologies, highlights the 1999 start-up projects, announces the OIT solicitation schedule for FY2000, and features the success of the Ohio diecasting showcase. One of the quarterly highlights was Secretary Richardson's presentation of a Certificate of Partnership to Malden Mills CEO Aaron Feuerstein at the dedication of the plant's new, advanced cogeneration system.
5. 7 MW Tornados for Dunn Paper mill power CHP plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffs, E.
The first commercial installation in the United States of Ruston's high efficiency Tornado gas turbine is now fully operational at the Dunn Paper Company's Port Huron, Michigan paper mill where they make special light weight papers for packaging and business forms. It's a cogeneration installation powered by three Tornados and two waste heat recovery boilers which provide the mill with all of its electricity and process steam requirements - at high overall thermal efficiency.
1985-11-01
arranged to maximize thermal output; - Plant will meet PURPA criteria for recognition as a "Qualifying Facility" (QF). 7587A 2 - GFC emissions will be...10. Plant must meet Public Utilities Regulatory Policies Act ( PURPA ) criteria for classification as a "Qualifying Facility" (QF). 11. Visual effect...assessments. 3 The Public Utilities Regulatory Policies Act ( PURPA ) which is administered by the Federal Energy Regulatory Commission (FERC), governs how a
Navy-New Hampshire Wind Energy Program.
1979-11-01
Hampshire 156 3.2.2.6.4 Legal/Institutional Barriers 157 3.2.2.6.4.1 Public Utilities Regulatory Policy Act ( PURPA ) 157 3.2.2.6.4.2 State of New...Regulatory Policy Act ( PURPA ) The greatest potential barrier to the introduction of wind turbine machines for the generation of electronic power is the...from qualified cogenerators at just and reasonable rates. Two of the provisions of PURPA are especially relc ant to the introduction of wind turbine
Economic Analysis of Coal-Fired Cogeneration Plants for Air Force Bases
1990-10-01
control . However, the existing stoker boilers at Griffiss AFB use lime scrubbers for flue gas desulfurization . The following input parameters were used to...boiler plant was newly installed in 1985 and is in excellent condition. Spray dryer scrubbers are used for flue gas desulfurization . 32 5.3.2 Heating Fuel...for stoker boilers in the previous heating plant studies, 1 ,3 and for sites that require flue gas desulfurization , an efficiency of 80% was used
Towards a Net Zero Building Cluster Energy Systems Analysis for a Brigade Combat Team Complex
2010-05-01
of technologies, like cogeneration or combined heat and power, waste heat recovery, biomass, geother- mal energy, solar heating (and cooling), and...peaks of individual buildings; thus the needed gen- eration and back-up capacity is smaller. To develop the community energy concept, energy models...overall thermal energy system, a hydraulic flow model (Figure 5) should be used to analyze critical capacities and flows in the system. This material is
Accumulation and subsequent utilization of waste heat
NASA Astrophysics Data System (ADS)
Koloničný, Jan; Richter, Aleš; Pavloková, Petra
2016-06-01
This article aims to introduce a special way of heat accumulation and primary operating characteristics. It is the unique way in which the waste heat from flue gas of biogas cogeneration station is stored in the system of storage tanks, into the heat transfer oil. Heat is subsequently transformed into water, from which is generated the low-pressure steam. Steam, at the time of peak electricity needs, spins the special designed turbine generator and produces electrical energy.
Lubrication contributes to improved landfill cogeneration plant operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-10-01
The Prince George`s county, Maryland, cogeneration plant consists of three lean-burn, 12-cylinder, Waukesha 5790GL turbocharged gas engines, each powering an 850 kW Kato generator. Four Waukesha F1197G engines run gas compressors that draw and compress gas from the landfill, pumping an average of 28000 m{sup 3}/day at 6.2 bar from 29 wells. Landfill gas is 50% methane, 30% carbon dioxide, 10% nitrogen and 10% other gas constituents. These other gas constituents consist of 160 chemical compounds, many of which are very destructive to engines and other equipment. Probably the worst of these are the total organic halide expressed as chloridemore » (TOH/CL), formed from the decomposition of household cleaning preparations and other materials containing chlorides. Landfill gas also contains an abundance of water, which combines not only with the TOH/CLs but with oxides of nitrogen, which are by-products of the combustion process, to form acids. To handle the highly contaminated landfill gas, the Waukesha Engine Division and people from Curtis Engine and Equipment modified the equipment and maintenance practices. One of the first changes was in lubrication. Curtis switched from a standard gas engine oil to Mobile Pegasus 446 oil, an SAE 40 oil that has a total base number (TBN) of 9.5, because of its extended acid-neutralizing capabilities.« less
Lin, Fu; Leyffer, Sven; Munson, Todd
2016-04-12
We study a two-stage mixed-integer linear program (MILP) with more than 1 million binary variables in the second stage. We develop a two-level approach by constructing a semi-coarse model that coarsens with respect to variables and a coarse model that coarsens with respect to both variables and constraints. We coarsen binary variables by selecting a small number of prespecified on/off profiles. We aggregate constraints by partitioning them into groups and taking convex combination over each group. With an appropriate choice of coarsened profiles, the semi-coarse model is guaranteed to find a feasible solution of the original problem and hence providesmore » an upper bound on the optimal solution. We show that solving a sequence of coarse models converges to the same upper bound with proven finite steps. This is achieved by adding violated constraints to coarse models until all constraints in the semi-coarse model are satisfied. We demonstrate the effectiveness of our approach in cogeneration for buildings. Here, the coarsened models allow us to obtain good approximate solutions at a fraction of the time required by solving the original problem. Extensive numerical experiments show that the two-level approach scales to large problems that are beyond the capacity of state-of-the-art commercial MILP solvers.« less
NASA Astrophysics Data System (ADS)
Li, W. S.; Lu, D. S.; Luo, J. L.; Chuang, K. T.
A proton exchange membrane fuel cell for chemicals and energy co-generation was set up with hydrocarbons ethane, propane and butane as fuels, and the electrochemical performance of the cell was studied by using linear potential sweep, alternating current impedance and gas chromatography. The cell performance can be improved to a great extent by increasing the platinum load in the catalyst, by treating the membrane with phosphoric acid and by elevating temperature. The improvement of cell performance by the increase of platinum load is ascribed to the increase of reaction sites for hydrocarbon oxidation, that by phosphoric acid treatment to the increase of proton conductivity in Nafion membrane, and that by elevating temperature to the improvement in thermodynamic as well as kinetic aspects. Only a small fraction of the hydrocarbon is converted to carbon dioxide in this cell during its power generation. The current efficiency is 5% for the conversion of ethane to carbon dioxide in the ethane/oxygen fuel cell with 20% carbon-supported platinum as catalyst and phosphoric acid-treated membrane as proton exchange membrane at 0.2 V, 80 °C and ambient pressure. The reaction activity of hydrocarbons at the anode is in the order of propane, butane and ethane. The possible chemicals produced from the cell were hydrocarbons with more than six carbons, which are inactive at the anode under cell conditions.
Consonni, S; Giugliano, M; Grosso, M
2005-01-01
This two-part paper assesses four strategies for energy recovery from municipal solid waste (MSW) by dedicated waste-to-energy (WTE) plants generating electricity through a steam cycle. The feedstock is the residue after materials recovery (MR), assumed to be 35% by weight of the collected MSW. In strategy 1, the MR residue is fed directly to a grate combustor. In strategy 2, the MR residue is first subjected to light mechanical treatment. In strategies 3 and 4, the MR residue is converted into RDF, which is combusted in a fluidized bed combustor. To examine the relevance of scale, we considered a small waste management system (WMS) serving 200,000 people and a large WMS serving 1,200,000 people. A variation of strategy 1 shows the potential of cogeneration with district heating. The assessment is carried out by a Life Cycle Analysis where the electricity generated by the WTE plant displaces electricity generated by fossil fuel-fired steam plants. Part A focuses on mass and energy balances, while Part B focuses on emissions and costs. Results show that treating the MR residue ahead of the WTE plant reduces energy recovery. The largest energy savings are achieved by combusting the MR residue "as is" in large scale plants; with cogeneration, primary energy savings can reach 2.5% of total societal energy use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Fu; Leyffer, Sven; Munson, Todd
We study a two-stage mixed-integer linear program (MILP) with more than 1 million binary variables in the second stage. We develop a two-level approach by constructing a semi-coarse model that coarsens with respect to variables and a coarse model that coarsens with respect to both variables and constraints. We coarsen binary variables by selecting a small number of prespecified on/off profiles. We aggregate constraints by partitioning them into groups and taking convex combination over each group. With an appropriate choice of coarsened profiles, the semi-coarse model is guaranteed to find a feasible solution of the original problem and hence providesmore » an upper bound on the optimal solution. We show that solving a sequence of coarse models converges to the same upper bound with proven finite steps. This is achieved by adding violated constraints to coarse models until all constraints in the semi-coarse model are satisfied. We demonstrate the effectiveness of our approach in cogeneration for buildings. Here, the coarsened models allow us to obtain good approximate solutions at a fraction of the time required by solving the original problem. Extensive numerical experiments show that the two-level approach scales to large problems that are beyond the capacity of state-of-the-art commercial MILP solvers.« less
Thermophotovoltaic potential applications for civilian and industrial use in Japan
NASA Astrophysics Data System (ADS)
Yamaguchi, Hiromi; Yamaguchi, Masafumi
1999-03-01
Investigative research on potential market for TPV power sources in Japan has been focused on how TPV can contribute to energy conservation and environmental protection and harmony. The application needs for TPV were surveyed in comparison with conventional engine or turbine generators and developing power generation technologies such as fuel cells or chemical batteries, etc. The investigation on the performance of commercial generators shows that regarding system efficiency, TPV can compete with conventional generators in the output power class of tens of kW. According to the sales for small scale generators in Japan, most of the generators below 10 kW class are utilized mainly for construction, communication, leisure, and that 10-100 kW class generators are for cogeneration in small buildings. Waste heat recovery in dispersed furnaces is another potential application of compact TPV cells. Exhaust heat from small scale incinerators and industrial furnaces is undesirable to be recorded into electricity due to excessive heat loss of the smaller steam turbine generators. Solar powered TPV is also of our concern as a natural energy use. From the viewpoint of applicability for TPV, portable generators cogeneration systems, and solar power plants were selected for our system consideration. Intermediate report on the feasibility study concerning such TPV systems is given as well as the review of the current status of competing power generation technologies in Japan.
Micro-cogen AMTEC systems for residential and transportation opportunities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mital, R.; Rasmussen, J.R.; Hunt, T.
1998-07-01
This paper describes the design and anticipated performance of high efficiency AMTEC systems suitable for natural gas fired micro-cogeneration for residential and transportation applications. AMTEC systems have a relatively flat efficiency curve from a few tens of watts to several kilowatts. This unique quality of AMTEC makes it well suited for micro-cogen as opposed to other technologies, such as internal combustion (IC) engines, which lose efficiency at low power levels. AMTEC also offers additional advantages of high efficiency, high reliability, low noise and low emissions. Combustion heated AMTEC cogeneration systems can also be used in trucks and trailers to keepmore » the diesel engines and cabs warm, provide electrical power for charging the battery and maintain power to the electrical systems during stand down periods. A market study indicates that residential micro-cogen units should have a design generating capacity between 0.5--2 kW. AMTEC systems producing 500 W net electric power have been designed and are presently being built. A 350 W prototype unit is being manufactured for a European firm as a trial unit for central heat and power from a home furnace. Modular one kilowatt units are also being designed that will allow combination into multi-kilowatt systems. The results of feasibility studies focused on price/Watt, efficiency, noise, emission, vibrations, expected lifetime and maintenance cost are also presented in this paper.« less
Load research manual. Volume 3. Load research for advanced technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandenburg, L.; Clarkson, G.; Grund, Jr., C.
1980-11-01
This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.
Georgetown Cogeneration Project as a Minor Source
This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The study was funded by the U.S. Trade and Development Agency on behalf of Kenya's Ministry of Agriculture. The purpose of the report is to determine the economic, technical, and financial viability of implementing bagasse based cogeneration projects in Kenya. The study is divided into the following sections: (1) Executive Summary, (2) Terms of Reference, (3) Bagasse Fuel for Generation, (4) The Electrical Power Situation in Kenya, (5) Export Electricity Potential from Nyando Sugar Belt, (6) Export Potential from Proposed New Sugar Factories; (7) Financial, (8) Project Financing, (9) Demonstration Project.
Application of sorption heat pumps for increasing of new power sources efficiency
NASA Astrophysics Data System (ADS)
Vasiliev, L.; Filatova, O.; Tsitovich, A.
2010-07-01
In the 21st century the way to increase the efficiency of new sources of energy is directly related with extended exploration of renewable energy. This modern tendency ensures the fuel economy needs to be realized with nature protection. The increasing of new power sources efficiency (cogeneration, trigeneration systems, fuel cells, photovoltaic systems) can be performed by application of solid sorption heat pumps, regrigerators, heat and cold accumulators, heat transformers, natural gas and hydrogen storage systems and efficient heat exchangers.
Pine State Power Cogeneration Project and International Paper Company
This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasten, P.R.; Rittenhouse, P.L.; Bartine, D.E.
1983-06-01
During 1982 the High-Temperature Gas-Cooled Reactor (HTGR) Technology Program at Oak Ridge National Laboratory (ORNL) continued to develop experimental data required for the design and licensing of cogeneration HTGRs. The program involves fuels and materials development (including metals, graphite, ceramic, and concrete materials), HTGR chemistry studies, structural component development and testing, reactor physics and shielding studies, performance testing of the reactor core support structure, and HTGR application and evaluation studies.
1985-07-01
and Operation 132 6.7.5 Safety 135 6.7.6 System Control Description 136 6.7.6.1 Coal Gasification 136 6.7.6.2 Gas Cooling, Cleaning and Compression...the hydrogen content. The gas is then desulfurized and heated before final polishing and feeding to the fuel cell. Receiving compressed fuel gas and...4 CO Shift 1 Stretford Desulfurizer 3 Gas Compressors 3 Material Handling(3) 3 Subtotal 39 Scheduled Shutdown 14 Total Annual Shutdown 53
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smalley, A.M.; Saleh, F.M.S.; Fontenot, M.
1984-08-01
Baseline data relevant to air quality are presented. The following are also included: geology and resource assessment, design well prospects in southwestern Louisiana, water quality monitoring, chemical analysis subsidence, microseismicity, geopressure-geothermal subsidence modeling, models of compaction and subsidence, sampling handling and preparation, brine chemistry, wetland resources, socioeconomic characteristics, impacts on wetlands, salinity, toxic metals, non-metal toxicants, temperature, subsidence, and socioeconomic impacts. (MHR)
1985-06-01
production; - Plant will meet PURPA criteria for recognition as a "Qualifying Facility" (QF). - Plant design allows for sale of byproducts, decreasing...export to the HCP be the minimum necessary to meet PURPA requirements and the remaining steam be used to produce electric power. Since the fuel cell...Policies Act ( PURPA ) criteria to be classified as a "Qualifying Facility" (QF). 14. Plant site conditions are as summarized in Table 2-1. I 9I I I IL
Influence of bio-additives on combustion of liquid fuels
NASA Astrophysics Data System (ADS)
Patsch, Marek; Durčanský, Peter
2016-06-01
In this contribution there are analyses of the course of the pressure curves, which were measured in the diesel engine MD UR IV, which is often used in cogeneration units. The results of the analyses confront the properties and quality of fuels. The measuring was realized with a constant rotation speed of the engine and by using different fuels. The fuels were pure diesel fuels and diesel fuel with bio-additives of hydrogenate RO (rape oil), FAME, and bioethanol.
Off-design analysis of a gas turbine powerplant augmented by steam injection using various fuels
NASA Technical Reports Server (NTRS)
Stochl, R. J.
1980-01-01
Results are compared using coal derived low and intermediate heating valve fuel gases and a conventional distillate. The results indicate that steam injection provides substantial increases in both power and efficiency within the available compressor surge margin. The results also indicate that these performance gains are relatively insensitive as to the type of fuel. Also, in a cogeneration application, steam injection could provide some degree of flexibility by varying the split between power and process steam.
Alternative Energy for Defense Conference
2011-10-26
Actuated Cooling and Cogeneration Systems Beginning TRL 3/4; End Goal TRL 5 METRICS: COP 0.7, 45 kg/ton US Army CERDEC Applications Portable Power NOW...Provided Power – Not Gov’t owned/operated, commercial grade, capacities vary • Rules of thumb: – 3 kW/person/day (bases with 5 to 3,500 population) – 4 kW...provide CONTINUOUS RATED POWER at these conditions: – 0.8 power factor (pf), lagging – Ambient temperatures up to 52°C (125°F) [-3% for each
Conservation and Renewable Energy Program: Bibliography, 1988 edition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaughan, K.H.
The 831 references covering the period 1980 through Feb. 1988, are arranged under the following: analysis and evaluation, building equipment, building thermal envelope systems and materials, community systems and cogeneration, residential conservation service, retrofit, advanced heat engine ceramics, alternative fuels, microemulsion fuels, industrial chemical heat pumps, materials for waste heat utilization, energy conversion and utilization materials, tribology, emergency energy conservation,inventions, electric energy systems, thermal storage, biofuels production, biotechnology, solar technology, geothermal, and continuous chromatography in multicomponent separations. An author index is included.
Energy alternative for industry: the high-temperature gas-cooled reactor steamer
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMain, A.T. Jr.; Blok, F.J.
1978-04-01
Large industrial complexes are faced with new requirements that will lead to a transition from such fluid fuels as natural gas and oil to such solid fuels as coal and uranium for supply of industrial energy. Power plants using these latter fuels will be of moderate size (800 to 1200 MW(thermal)) and will generally have the capability of co-generating electric power and process steam. A study has been made regarding use of the 840-MW(thermal) Fort St. Vrain high-temperature gas-cooled reactor (HTGR) design for industrial applications. The initial conceptual design (referred to as the HTGR Steamer) is substantially simplified relative tomore » Fort St. Vrain in that outlet helium and steam temperatures are lower and the reheat section is deleted from the steam generators. The Steamer has four independent steam generating loops producing a total of 277 kg/s (2.2 x 10/sup 6/ lb/h) of prime steam at 4.5 MPa/672 K (650 psia/750/sup 0/F). The unit co-generates 46 MW(electric) and provides process steam at 8.31 MPa/762 K(1200 psia/912/sup 0/F). The basic configuration and much of the equipment are retained from the Fort St. Vrain design. The system has inherent safety features important for industrial applications. These and other features indicate that the HTGR Steamer is an industrial energy option deserving additional evaluation. Subsequent work will focus on parallel design optimization and application studies.« less
Evaluation of solar sludge drying alternatives by costs and area requirements.
Kurt, Mayıs; Aksoy, Ayşegül; Sanin, F Dilek
2015-10-01
Thermal drying is a common method to reach above 90% dry solids content (DS) in sludge. However, thermal drying requires high amount of energy and can be expensive. A greenhouse solar dryer (GSD) can be a cost-effective substitute if the drying performance, which is typically 70% DS, can be increased by additional heat. In this study feasibility of GSD supported with solar panels is evaluated as an alternative to thermal dryers to reach 90% DS. Evaluations are based on capital and O&M costs as well as area requirements for 37 wastewater treatment plants (WWTPs) with various sludge production rates. Costs for the supported GSD system are compared to that of conventional and co-generation thermal dryers. To calculate the optimal costs associated with the drying system, an optimization model was developed in which area limitation was a constraint. Results showed that total cost was minimum when the DS in the GSD (DS(m,i)) was equal to the maximum attainable value (70% DS). On average, 58% of the total cost and 38% of total required area were associated with the GSD. Variations in costs for 37 WWTPs were due to differences in initial DS (DS(i,i)) and sludge production rates, indicating the importance of dewatering to lower drying costs. For large plants, GSD supported with solar panels provided savings in total costs especially in long term when compared to conventional and co-generation thermal dryers. Copyright © 2015 Elsevier Ltd. All rights reserved.
Occupational carbon monoxide poisoning in Washington State, 2000-2005.
Reeb-Whitaker, Carolyn K; Bonauto, David K; Whittaker, Stephen G; Adams, Darrin
2010-10-01
Washington State workers' compensation data can be used to guide prevention efforts focused on occupational carbon monoxide (CO) poisoning. Between 2000 and 2005, a total of 345 individual claims comprising 221 different exposure incidents were identified for the 6-year time period. The construction industry had 43 (20%) CO incidents, followed by wholesale trade with 32 (15%), and agriculture with 27 (12%) incidents. Fuel-powered forklifts caused 29% of all incidents, while autos/trucks/buses were responsible for 26%. The number of forklift incidents in fruit packing and cold storage companies declined significantly from 1994 through 2007 (Spearman's rho = 0.6659, p < 0.01). While this study used multiple medical records from workers' compensation claims to identify CO poisoning, a surveillance system that lacks extensive medical records may rely principally on carboxyhemoglobin (COHb) tests. This study demonstrated that 71% of the identified workers' compensation claims had associated COHb tests. The recurrence and timing of CO poisoning as well as control of the CO-generating source were determined. Approximately 8% of all work sites had recurring CO poisoning incidents. Two percent experienced a recurrent incident within 16 days of the initial incident, and 6% experienced a recurrent incident between 16 days and 3 years after the initial incident. Sixty-seven percent of claimants exposed to CO were not in direct control of the CO-generating source; this has implications for CO prevention and underscores the need for all employees to be trained on CO hazards.
Commercial sector solid oxide fuel cell business assessment. Interim report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schafer, P.
Estimates for the commercial potential of solid oxide fuel cells (SOFCs) from the year 2001 to 2015 is 4 billion MWh. Their quiet operation, low cost, efficiency, and small size could make SOFCs ideal power sources for commercial customers. To better understand the market, this study had three main objectives: (1) identify the extent of the commercial market potential; (2) describe the most likely commercial segments and locations for SOFCs to be competitive; and, (3) determine the most appropriate product sizes. To profile commercial sectors by energy use, investigators conducted a market segmentation analysis. They classified markets within sectors asmore » cogeneration and electric-only applications. Investigators then performed a market analysis to estimate the cost competitiveness of SOFC energy production by state, segment, and operating mode (cogeneration or electric-only). To determine which locations and sectors would be competitive with current utility retail rates, they used the cost per kWh of electrical energy produced by SOFC technology. Study results indicated that three sizes of SOFCs would meet most market capacity requirements: 20, 100, and 250 kW. The largest number of potential SOFC building applications fell into these sectors: education, health care, food service, and skilled nursing. In terms of competitive building applications, California, New York, Illinois, Texas, and Michigan were the top states. The potential market for SOFCs, however, could be much smaller if the pressures of deregulation decrease commercial retail rates or if the rates themselves increase more slowly than expected.« less
Blumthaler, Ingrid; Oberst, Ulrich
2012-03-01
Control design belongs to the most important and difficult tasks of control engineering and has therefore been treated by many prominent researchers and in many textbooks, the systems being generally described by their transfer matrices or by Rosenbrock equations and more recently also as behaviors. Our approach to controller design uses, in addition to the ideas of our predecessors on coprime factorizations of transfer matrices and on the parametrization of stabilizing compensators, a new mathematical technique which enables simpler design and also new theorems in spite of the many outstanding results of the literature: (1) We use an injective cogenerator signal module ℱ over the polynomial algebra [Formula: see text] (F an infinite field), a saturated multiplicatively closed set T of stable polynomials and its quotient ring [Formula: see text] of stable rational functions. This enables the simultaneous treatment of continuous and discrete systems and of all notions of stability, called T-stability. We investigate stabilizing control design by output feedback of input/output (IO) behaviors and study the full feedback IO behavior, especially its autonomous part and not only its transfer matrix. (2) The new technique is characterized by the permanent application of the injective cogenerator quotient signal module [Formula: see text] and of quotient behaviors [Formula: see text] of [Formula: see text]-behaviors B. (3) For the control tasks of tracking, disturbance rejection, model matching, and decoupling and not necessarily proper plants we derive necessary and sufficient conditions for the existence of proper stabilizing compensators with proper and stable closed loop behaviors, parametrize all such compensators as IO behaviors and not only their transfer matrices and give new algorithms for their construction. Moreover we solve the problem of pole placement or spectral assignability for the complete feedback behavior. The properness of the full feedback behavior ensures the absence of impulsive solutions in the continuous case, and that of the compensator enables its realization by Kalman state space equations or elementary building blocks. We note that every behavior admits an IO decomposition with proper transfer matrix, but that most of these decompositions do not have this property, and therefore we do not assume the properness of the plant. (4) The new technique can also be applied to more general control interconnections according to Willems, in particular to two-parameter feedback compensators and to the recent tracking framework of Fiaz/Takaba/Trentelman. In contrast to these authors, however, we pay special attention to the properness of all constructed transfer matrices which requires more subtle algorithms.
NASA Astrophysics Data System (ADS)
Valamin, A. E.; Kultyshev, A. Yu.; Shibaev, T. L.; Gol'dberg, A. A.; Sakhnin, Yu. A.; Stepanov, M. Yu.; Bilan, V. N.; Kadkina, I. V.
2016-11-01
The selection of a cogeneration steam turbine unit (STU) for the reconstruction of power units with a T-250/300-23.5 turbine is substantiated by the example of power unit no. 9 at the cogeneration power station no. 22 (TETs-22) of Mosenergo Company. Series T-250 steam turbines have been developed for combined heat and power generation. A total of 31 turbines were manufactured. By the end of 2015, the total operation time of prototype power units with the T-250/300-23.5 turbine exceeded 290000 hours. Considering the expiry of the service life, the decision was made that the reconstruction of the power unit at st. no. 9 of TETs-22 should be the first priority. The main issues that arose in developing this project—the customer's requirements and the request for the reconstruction, the view on certain problems of Ural Turbine Works (UTZ) as the manufacturer of the main power unit equipment, and the opinions of other project parties—are examined. The decisions were made with account taken of the experience in operation of all Series T-250 turbines and the results of long-term discussions of pressing problems at scientific and technical councils, meetings, and negotiations. For the new power unit, the following parameters have been set: a live steam pressure of 23.5 MPa and live steam/reheat temperature of 565/565°C. Considering that the boiler equipment will be upgraded, the live steam flow is increased up to 1030 t/h. The reconstruction activities involving the replacement of the existing turbine with a new one will yield a service life of 250000 hours for turbine parts exposed to a temperature of 450°C or higher and 200000 hours for pipeline components. Hence, the decision has been made to reuse the arrangement of the existing turbine: a four-cylinder turbine unit comprising a high-pressure cylinder (HPC), two intermediate pressure cylinders (IPC-1 & 2), and a low-pressure cylinder (LPC). The flow path in the new turbine will have active blading in LPC and IPC-1. The information is also presented on the use of the existing foundations, the fact that the overall dimensions of the turbine unit compartment are not changed, the selection of the new turbine type, and the solutions adopted on the basis of this information as to LPC blading, steam admission type, issues associated with thermal displacements, etc.
Microinstallations Based on Renewable Energy Sources in the Construction Sector
NASA Astrophysics Data System (ADS)
Kurzak, Lucjan
2017-10-01
The focus of this paper is on the status and prognoses of the use of microinstallations based on renewable energy sources to supply heat and power. The technologies that have been important in Europe and Poland for microgeneration of electricity include photovoltaic systems, micro wind turbines and co-generation systems. Solar collectors, heat pumps and biomass have also been used to generate heat. Microinstallations for renewable energy sources represent the initial point and the foundation for the development of micro networks, intelligent networks and the whole prosumer energy sector.
Georgetown Cogeneration Project as a Minor Source
This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Policy and Guidance Database available at www2.epa.gov/title-v-operating-permits/title-v-operating-permit-policy-and-guidance-document-index. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
Advanced energy system program
NASA Astrophysics Data System (ADS)
Trester, K.
1989-02-01
The objectives of the program are to design, develop and demonstrate a natural-gas-fueled, highly recuperated, 50 kW Brayton-cycle cogeneration system for commercial, institutional, and multifamily residential applications. Marketing studies have shown that this Advanced Energy System (AES), with its many unique and cost-effective features, has the potential to offer significant reductions in annual electrical and thermal energy costs to the consumer. Specific advantages of the system that result in low cost of ownership are high electrical efficiency (30 percent, HHV), low maintenance, high reliability and long life (20 years).
Cogeneration technology alternatives study. Volume 2: Industrial process characteristics
NASA Technical Reports Server (NTRS)
1980-01-01
Information and data for 26 industrial processes are presented. The following information is given for each process: (1) a description of the process including the annual energy consumption and product production and plant capacity; (2) the energy requirements of the process for each unit of production and the detailed data concerning electrical energy requirements and also hot water, steam, and direct fired thermal requirements; (3) anticipated trends affecting energy requirements with new process or production technologies; and (4) representative plant data including capacity and projected requirements through the year 2000.
This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
The `advanced DIR-MCFC development' project, an overview
NASA Astrophysics Data System (ADS)
Kortbeek, P. J.; Ottervanger, R.
An overview is given of the approach and mid-term status of the joint European `Advanced DIR-MCFC Development' project, in which BCN, BG plc, GDF, ECN, Stork, Schelde and Sydkraft co-operate. Hospitals are identified as an attractive initial market for cogeneration direct internal reforming-molten carbonate fuel cell (DIR-MCFC) systems in the size of 400 kWe. Innovative system and stack design concepts are being developed for this application. The `SMARTER' system, based on DIR stacks, combines high electric efficiency and a wide operational window with optimal system simplicity and low cost.
Solar Total Energy Project (STEP) Performance Analysis of High Temperature Energy Storage Subsystem
NASA Technical Reports Server (NTRS)
Moore, D. M.
1984-01-01
The 1982 milestones and lessons learned; performance in 1983; a typical day's operation; collector field performance and thermal losses; and formal testing are highlighted. An initial test that involves characterizing the high temperature storage (hts) subsystem is emphasized. The primary element is on 11,000 gallon storage tank that provides energy to the steam generator during transient solar conditions or extends operating time. Overnight, thermal losses were analyzed. The length of time the system is operated at various levels of cogeneration using stored energy is reviewed.
This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
2013-05-15
rates, but conservatively, two weeks to several months), firm delivery contracts (which are based on the capacity of the transmission pipelines and...gas is not guaranteed as it is not part of the capacity planning process). 0 20 40 60 80 100 120 0 2 4 6 8 10 12 D ur at io n of st or ag e su pp...military installations. For example, Tinker AFB, Robins AFB, and MCAGCC Twentynine Palms all have natural gas-fired generation or cogeneration on site
2005-01-01
graphite flakes for infrared obscuration are being deployed for training scenarios. The effect of this combination on avian species was unknown. Our...Hematological response was normal and no toxic effects in eryth- rocytes or leukocytes were found. White blood cell counts, spleen weights, and incidence of...5 List of Figures and Tables Figures 1. Exposure system used for testing the effects of fog oil and graphite flake aerosols on avian health
Could the Extended Phenotype Extend to the Cellular and Subcellular Levels in Insect-Induced Galls?
Carneiro, Renê Gonçalves da Silva; Pacheco, Priscilla; Isaias, Rosy Mary dos Santos
2015-01-01
Neo-ontogenesis of plant galls involves redifferentiation of host plant tissues to express new phenotypes, when new cell properties are established via structural-functional remodeling. Herein, Psidium cattleianum leaves and Nothotrioza cattleiani galls are analyzed by developmental anatomy, cytometry and immunocytochemistry of cell walls. We address hypothesis-driven questions concerning the organogenesis of globoid galls in the association of P. cattleianum - N. cattleianum, and P. myrtoides - N. myrtoidis. These double co-generic systems represent good models for comparing final gall shapes and cell lineages functionalities under the perspective of convergent plant-dependent or divergent insect-induced characteristics. Gall induction, and growth and development are similar in both galls, but homologous cell lineages exhibit divergent degrees of cell hypertrophy and directions of elongation. Median cortical cells in P. cattleianum galls hypertrophy the most, while in P. myrtoides galls there is a centrifugal gradient of cell hypertrophy. Cortical cells in P. cattleianum galls tend to anisotropy, while P. myrtoidis galls have isotropically hypertrophied cells. Immunocytochemistry evidences the chemical identity and functional traits of cell lineages: epidermal cells walls have homogalacturonans (HGAs) and galactans, which confer rigidity to sites of enhanced cell division; oil gland cell walls have arabinogalactan proteins (AGPs) that help avoiding cell death; and parenchyma cell walls have HGAs, galactans and arabinans, which confer porosity. Variations in such chemical identities are related to specific sites of hypertrophy. Even though the double co-generic models have the same macroscopic phenotype, the globoid morphotype, current analyses indicate that the extended phenotype of N. cattleiani is substantiated by cellular and subcellular specificities. PMID:26053863
Co-generating synthetic parts toward a self-replicating system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jun; Haas, Wilhelm; Jackson, Kirsten
To build replicating systems with new functions, the engineering of existing biological machineries requires a sensible strategy. Protein synthesis Using Recombinant Elements (PURE) system consists of the desired components for transcription, translation, aminoacylation and energy regeneration. PURE, might be the basis for a radically alterable, lifelike system after optimization. Here, we regenerated 54 E. coli ribosomal (r-) proteins individually from DNA templates in the PURE system. We show that using stable isotope labeling with amino acids, mass spectrometry based quantitative proteomics could detect 26 of the 33 50S and 20 of the 21 30S subunit r-proteins when co-expressed in batchmore » format PURE system. By optimizing DNA template concentrations and adapting a miniaturized Fluid Array Device with optimized feeding solution, we were able to cogenerate and detect at least 29 of the 33 50S and all of the 21 30S subunit r-proteins in one pot. The boost on yield of a single r-protein in co-expression pool varied from ~1.5 to 5-fold compared to the batch mode, with up to ~ 2.4 µM yield for a single r-protein. Reconstituted ribosomes under physiological condition from PURE system synthesized 30S r-proteins and native 16S rRNA showed ~13% activity of native 70S ribosomes, which increased to 21% when supplemented with GroEL/ES. As a result, this work also points to what is still needed to obtain self-replicating synthetic ribosomes in-situ in the PURE system.« less
Co-generating synthetic parts toward a self-replicating system
Li, Jun; Haas, Wilhelm; Jackson, Kirsten; ...
2017-03-23
To build replicating systems with new functions, the engineering of existing biological machineries requires a sensible strategy. Protein synthesis Using Recombinant Elements (PURE) system consists of the desired components for transcription, translation, aminoacylation and energy regeneration. PURE, might be the basis for a radically alterable, lifelike system after optimization. Here, we regenerated 54 E. coli ribosomal (r-) proteins individually from DNA templates in the PURE system. We show that using stable isotope labeling with amino acids, mass spectrometry based quantitative proteomics could detect 26 of the 33 50S and 20 of the 21 30S subunit r-proteins when co-expressed in batchmore » format PURE system. By optimizing DNA template concentrations and adapting a miniaturized Fluid Array Device with optimized feeding solution, we were able to cogenerate and detect at least 29 of the 33 50S and all of the 21 30S subunit r-proteins in one pot. The boost on yield of a single r-protein in co-expression pool varied from ~1.5 to 5-fold compared to the batch mode, with up to ~ 2.4 µM yield for a single r-protein. Reconstituted ribosomes under physiological condition from PURE system synthesized 30S r-proteins and native 16S rRNA showed ~13% activity of native 70S ribosomes, which increased to 21% when supplemented with GroEL/ES. As a result, this work also points to what is still needed to obtain self-replicating synthetic ribosomes in-situ in the PURE system.« less
NASA Astrophysics Data System (ADS)
McNeese, L. E.
1981-01-01
Increased utilization of coal and other fossil fuel alternatives as sources of clean energy is reported. The following topics are discussed: coal conversion development, chemical research and development, materials technology, component development and process evaluation studies, technical support to major liquefaction projects, process analysis and engineering evaluations, fossil energy environmental analysis, flue gas desulfurization, solid waste disposal, coal preparation waste utilization, plant control development, atmospheric fluidized bed coal combustor for cogeneration, TVA FBC demonstration plant program technical support, PFBC systems analysis, fossil fuel applications assessments, performance assurance system support for fossil energy projects, international energy technology assessment, and general equilibrium models of liquid and gaseous fuel supplies.
The Evaluation of Feasibility of Thermal Energy Storage System at Riga TPP-2
NASA Astrophysics Data System (ADS)
Ivanova, P.; Linkevics, O.; Cers, A.
2015-12-01
The installation of thermal energy storage system (TES) provides the optimisation of energy source, energy security supply, power plant operation and energy production flexibility. The aim of the present research is to evaluate the feasibility of thermal energy system installation at Riga TPP-2. The six modes were investigated: four for non-heating periods and two for heating periods. Different research methods were used: data statistic processing, data analysis, analogy, forecasting, financial method and correlation and regression method. In the end, the best mode was chosen - the increase of cogeneration unit efficiency during the summer.
Fuel cell power plant economic and operational considerations
NASA Technical Reports Server (NTRS)
Lance, J. R.
1984-01-01
Fuel cell power plants intended for electric utility and cogeneration applications are now in the design and construction stage. This paper describes economic and operational considerations being used in the development and design of plants utilizing air cooled phosphoric acid fuel cells. Fuel cell power plants have some unique characteristics relative to other types of power plants. As a result it was necessary to develop specific definitions of the fuel cell power plant characteristics in order to perform cost of electricity calculations. This paper describes these characteristics and describes the economic analyses used in the Westinghouse fuel cell power plant program.
NASA Astrophysics Data System (ADS)
Chinery, G. T.; Wood, J. M.
1985-08-01
This paper describes the Tennessee Valley Authority's (TVA) current photovoltaic (PV) activities. These include four roof-mounted 4 kWp residential arrays (which are also Southeast Residential Station field sites) and two 5-6 kWp commercial sites, all grid connected with no battery storage. Also included are approximately 30 kWp of non-grid-connected remote sites with storage (remote lighting, weather stations, etc.). Monitoring results from the two 'online' residential systems are presented. Finally, TVA's future PV plans are discussed, both with respect to interfacing with a multitude of residential and commercial cogenerators and with regard to possible TVA PV central station plans.
This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
Proceedings of the Alternate Energy Systems Seminar
NASA Technical Reports Server (NTRS)
1978-01-01
The Alternative Energy Systems Seminar was held on March 30, 1978, and was sponsored jointly be the Southwest District Office of the U.S. Department of Energy and JPL. The seminar was an experiment in information exchange with the aim of presenting, in a single day, status and prospects for a number of advanced energy systems to a diverse, largely nontechnical audience, and to solicit post-seminar responses from that audience as to the seminar's usefulness. The major systems presented are: (1) Solar Photovoltaic; (2) Geothermal; (3) Cogeneration Power; (4) Solar Thermal; (5) Solar Heating and Cooling; (6) Wind Energy; and (7) Systems Considerations.
Klein, Gerwin; Andronick, June; Keller, Gabriele; Matichuk, Daniel; Murray, Toby; O'Connor, Liam
2017-10-13
We present recent work on building and scaling trustworthy systems with formal, machine-checkable proof from the ground up, including the operating system kernel, at the level of binary machine code. We first give a brief overview of the seL4 microkernel verification and how it can be used to build verified systems. We then show two complementary techniques for scaling these methods to larger systems: proof engineering, to estimate verification effort; and code/proof co-generation, for scalable development of provably trustworthy applications.This article is part of the themed issue 'Verified trustworthy software systems'. © 2017 The Author(s).
How gas cools (or, apples can fall up)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-01-01
This primer on gas cooling systems explains the basics of heat exchange within a refrigeration system, the principle of reverse-cycle refrigeration, and how a gas-engine-driven heat pump can provide cooling, additional winter heating capacity, and hot water year-round. Gas cooling equipment available or under development include natural gas chillers, engine-driven chillers, and absorption chillers. In cogeneration systems, heat recovered from an engine's exhaust and coolant may be used in an absorption chiller to provide air-conditioning. Gas desiccant cooling systems may be used in buildings and businesses that are sensitive to high humidity levels.
Israel Electric joins oil shale power plant project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1986-12-01
The Israel Electric Corporation has purchased a 25% share in PAMA (Energy Resources Development, Ltd). PAMA is planning to build a 7 1/2 megawatt shale-fired demonstration plant at Mishor Rotem in Israel. The demonstration cogeneration plant is being designed to produce 42 tons/hours of steam for use in nearby phosphate plants, and also produce electricity. Construction of the demonstration plant is expected to begin in early 1987 and be completed within 2 years. It will be based on fluidized bed technology. Successful operation of the demo plant could then lead to a 50 to 100 megawatt or larger commercial plant.
This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
NASA Technical Reports Server (NTRS)
Liu, Gao-Lian
1991-01-01
Advances in inverse design and optimization theory in engineering fields in China are presented. Two original approaches, the image-space approach and the variational approach, are discussed in terms of turbomachine aerodynamic inverse design. Other areas of research in turbomachine aerodynamic inverse design include the improved mean-streamline (stream surface) method and optimization theory based on optimal control. Among the additional engineering fields discussed are the following: the inverse problem of heat conduction, free-surface flow, variational cogeneration of optimal grid and flow field, and optimal meshing theory of gears.
Citizen Science: Participatory Monitoring of Water Resources Management in Mustang District, Nepal
NASA Astrophysics Data System (ADS)
Regmi, S.; Bhusal, J.; Gurung, P.; Ochoa-Tocachi, B. F.; Buytaert, W.
2016-12-01
Abstract The Mustang region of the Himalayas has unique geographical and climatic features. This region is characterized by a cold-arid climate with total annual precipitation of less than 300mm. Agriculture and livestock grazing lands are the major ecosystem services, which support directly the livelihoods of local populations yet, are strongly determined by low water availability. As a result, optimizing water resources management is paramount to support local development, but this is severely complicated by the lack of information about water availability. This problem is further aggravated by increasing pressure on the social, physical and climatic environments. In order to support the management of scarce water in irrigation and domestic uses, stream flow and precipitation monitoring networks were established using a participatory approach under the principle of citizen science. Data collection, and the following interpretation and application of the co-generated knowledge relies on local users, whereas the establishment of the system, knowledge co-generation, and development of application tools particularly is part of a collaboration of members of the general public with professional scientists. We show how the resulting data enable local users to quantify the water balance in the area and reduce the uncertainty associated to data-scarcity, which leads to the generation of useable information about water availability for irrigation, livestock grazing, and domestic demand. We contrast the current scenario of water use, under different conditions of natural variability and environmental change, with an optimized water management strategy generated and agreed with local users. This approach contributes to an optimal use of water, to an improvement in ecosystem services supporting to livelihood development and economic progress of local populations. Key words: ecosystem services, climate change, water balance, knowledge generation, irrigation
Saptio-temporal complementarity of wind and solar power in India
NASA Astrophysics Data System (ADS)
Lolla, Savita; Baidya Roy, Somnath; Chowdhury, Sourangshu
2015-04-01
Wind and solar power are likely to be a part of the solution to the climate change problem. That is why they feature prominently in the energy policies of all industrial economies including India. One of the major hindrances that is preventing an explosive growth of wind and solar energy is the issue of intermittency. This is a major problem because in a rapidly moving economy, energy production must match the patterns of energy demand. Moreover, sudden increase and decrease in energy supply may destabilize the power grids leading to disruptions in power supply. In this work we explore if the patterns of variability in wind and solar energy availability can offset each other so that a constant supply can be guaranteed. As a first step, this work focuses on seasonal-scale variability for each of the 5 regional power transmission grids in India. Communication within each grid is better than communication between grids. Hence, it is assumed that the grids can switch sources relatively easily. Wind and solar resources are estimated using the MERRA Reanalysis data for the 1979-2013 period. Solar resources are calculated with a 20% conversion efficiency. Wind resources are estimated using a 2 MW turbine power curve. Total resources are obtained by optimizing location and number of wind/solar energy farms. Preliminary results show that the southern and western grids are more appropriate for cogeneration than the other grids. Many studies on wind-solar cogeneration have focused on temporal complementarity at local scale. However, this is one of the first studies to explore spatial complementarity over regional scales. This project may help accelerate renewable energy penetration in India by identifying regional grid(s) where the renewable energy intermittency problem can be minimized.
NASA Astrophysics Data System (ADS)
Prinsloo, Gerro; Dobson, Robert; Brent, Alan; Mammoli, Andrea
2016-05-01
Concentrating solar power co-generation systems have been identified as potential stand-alone solar energy supply solutions in remote rural energy applications. This study describes the modelling and synthesis of a combined heat and power Stirling CSP system in order to evaluate its potential performance in small off-grid rural village applications in Africa. This Stirling micro-Combined Heat and Power (micro-CHP) system has a 1 kW electric capacity, with 3 kW of thermal generation capacity which is produced as waste heat recovered from the solar power generation process. As part of the development of an intelligent microgrid control and distribution solution, the Trinum micro-CHP system and other co-generation systems are systematically being modelled on the TRNSYS simulation platform. This paper describes the modelling and simulation of the Trinum micro-CHP configuration on TRNSYS as part of the process to develop the control automation solution for the smart rural microgrid in which the Trinum will serve as a solar powerpack. The results present simulated performance outputs for the Trinum micro-CHP system for a number of remote rural locations in Africa computed from real-time TRNSYS solar irradiation and weather data (yearly, monthly, daily) for the relevant locations. The focus of this paper is on the parametric modelling of the Trinum Stirling micro-CHP system, with specific reference to this system as a TRNSYS functional block in the microgrid simulation. The model is used to forecast the solar energy harvesting potential of the Trinum micro-CHP unit at a number of remote rural sites in Africa.
Soviet steam generator technology: fossil fuel and nuclear power plants. [Glossary included
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosengaus, J.
1987-01-01
In the Soviet Union, particular operational requirements, coupled with a centralized planning system adopted in the 1920s, have led to a current technology which differs in significant ways from its counterparts elsewhere in the would and particularly in the United States. However, the monograph has a broader value in that it traces the development of steam generators in response to the industrial requirements of a major nation dealing with the global energy situation. Specifically, it shows how Soviet steam generator technology evolved as a result of changing industrial requirements, fuel availability, and national fuel utilization policy. The monograph begins withmore » a brief technical introduction focusing on steam-turbine power plants, and includes a discussion of the Soviet Union's regional power supply (GRES) networks and heat and power plant (TETs) systems. TETs may be described as large central co-generating stations which, in addition to electricity, provide heat in the form of steam and hot water. Plants of this type are a common feature of the USSR today. The adoption of these cogeneration units as a matter of national policy has had a central influence on Soviet steam generator technology which can be traced throughout the monograph. The six chapters contain: a short history of steam generators in the USSR; steam generator design and manufacture in the USSR; boiler and furnace assemblies for fossil fuel-fired power stations; auxiliary components; steam generators in nuclear power plants; and the current status of the Soviet steam generator industry. Chapters have been abstracted separately. A glossary is included containing abbreviations and acronyms of USSR organizations. 26 references.« less
Designing for knowledge: bridging socio-hydrological monitoring and beyond
NASA Astrophysics Data System (ADS)
Mao, F.; Clark, J.; Buytaert, W.; Ochoa-Tocachi, B. F.; Hannah, D. M.
2016-12-01
Many methods and applications have been developed to research socio-hydrological systems, such as participatory monitoring, environmental big data processing and sensor network data transmission. However, these data-centred activities are insufficient to guarantee successful knowledge co-generation, decision making or governance. This research suggests a shift of attentions in designing socio-hydrological monitoring tools, from designing for data to designing for knowledge (DfK). Compared to the former strategy, DfK has at least three features as follows. (1) Why monitor? DfK demands the data produced by the newly introduced monitoring application to have potentials to generate socio-hydrological knowledge that supports decision making or management. It means that when designing a monitoring tool, we should not only answer how to collect data, but also questions such as how to best use the collected data in the form of knowledge. (2) What is the role of monitoring? DfK admits that the socio-hydrological data and knowledge generated by monitoring is just one of many kinds to support decision making and management. It means that the importance of monitoring and scientific evidence should not be overestimated, and knowledge cogeneration and synthesis should be considered in advance in the monitoring design process. (3) Who participate? DfK implies a wider engagement of stakeholders, which is not restricted between volunteers as data collectors and providers, and scientist and researcher communities as main data users. It requires a broader consideration of users, including not only data collectors, processors and interpreters, but also local and indigenous knowledge providers, and decision makers who use the knowledge and data. In summary, this research proposes a knowledge-centred strategy in designing participatory socio-hydrological monitoring tools, in order to make monitoring more useful and effective.
Design of stationary PEFC system configurations to meet heat and power demands
NASA Astrophysics Data System (ADS)
Wallmark, Cecilia; Alvfors, Per
This paper presents heat and power efficiencies of a modeled PEFC system and the methods used to create the system configuration. The paper also includes an example of a simulated fuel cell system supplying a building in Sweden with heat and power. The main method used to create an applicable fuel cell system configuration is pinch technology. This technology is used to evaluate and design a heat exchanger network for a PEFC system working under stationary conditions, in order to find a solution with high heat utilization. The heat exchanger network in the system connecting the reformer, the burner, gas cleaning, hot-water storage and the PEFC stack will affect the heat transferred to the hot-water storage and thereby the heating of the building. The fuel, natural gas, is reformed to a hydrogen-rich gas within a slightly pressurized system. The fuel processor investigated is steam reforming, followed by high- and low-temperature shift reactors and preferential oxidation. The system is connected to the electrical grid for backup and peak demands and to a hot-water storage to meet the varying heat demand for the building. The procedure for designing the fuel cell system installation as co-generation system is described, and the system is simulated for a specific building in Sweden during 1 year. The results show that the fuel cell system in combination with a burner and hot-water storage could supply the building with the required heat without exceeding any of the given limitations. The designed co-generation system will provide the building with most of its power requirements and would further generate income by sale of electricity to the power grid.
NASA Astrophysics Data System (ADS)
Dubrovskii, V. G.; Zubov, A. P.; Koshelev, S. A.
2018-06-01
Presently, when the structure of energy consumption by industrial enterprises is being changed, many type PT turbine units operate with limitations imposed on their operating conditions, while type R backpressure turbines are often shut down for a long time or even removed from operation. Thus, the problem of using steam previously intended for process needs combined with the loading of the main equipment and additional generation of power and heat becomes urgent for many power stations. Three main ways for solving this problem are examined in this paper. Potential alternatives for retrofitting of cogeneration power stations (TETS) with types PT and R turbines are discussed. Each alternative solves a specific problem brought about by the actual operating conditions of a turbine at a specific TETs. The results of retrofitting of PT-80-130 turbines with an increase in the throughput capacity of the intermediate pressure cylinder (IPC) and R-50-130 turbines with installation of an additional low-pressure cylinder (LPC) are presented. The experience in operation of the retrofitted R-50-130 turbine with an unconventional arrangement where an additional LPC is installed upstream the high-pressure cylinder (HPC) rather than between the generator and HPC is also described. The experience in the upgrading of TETs with installation of bottom steam turbines driven by steam from a process steam extraction that is not demanded for is presented. Depending on the conditions at a specific TETs, a bottom steam turbine can be installed on a new foundation or in the compartment of a dismounted turbine with the use of serviceable auxiliary and heat-exchange equipment.
Opportunities for Automated Demand Response in California Wastewater Treatment Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aghajanzadeh, Arian; Wray, Craig; McKane, Aimee
Previous research over a period of six years has identified wastewater treatment facilities as good candidates for demand response (DR), automated demand response (Auto-DR), and Energy Efficiency (EE) measures. This report summarizes that work, including the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy used and demand, as well as details of the wastewater treatment process. It also discusses control systems and automated demand response opportunities. Furthermore, this report summarizes the DR potential of three wastewater treatment facilities. In particular, Lawrence Berkeley National Laboratory (LBNL) has collected data at these facilities from control systems, submetered processmore » equipment, utility electricity demand records, and governmental weather stations. The collected data were then used to generate a summary of wastewater power demand, factors affecting that demand, and demand response capabilities. These case studies show that facilities that have implemented energy efficiency measures and that have centralized control systems are well suited to shed or shift electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. In summary, municipal wastewater treatment energy demand in California is large, and energy-intensive equipment offers significant potential for automated demand response. In particular, large load reductions were achieved by targeting effluent pumps and centrifuges. One of the limiting factors to implementing demand response is the reaction of effluent turbidity to reduced aeration at an earlier stage of the process. Another limiting factor is that cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities, limit a facility’s potential to participate in other DR activities.« less
Fixed solar concentrator-collector-satelite receiver and co-generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1985-01-01
An insolation and micro wave receiver fixedly installed in alignment with the suns azimuth and within the look angle of a satellite, and comprised of holographic windows recorded according to time related to the suns position as zone plates to concentrate infrared light into a Rankine cycle power generating receiver and to columnate ultraviolet light onto a photo voltaic power generating plane, utilizing a micro wave dish as the substrate support of photo voltaic cells and as a condenser of the Rankine cycle operating an induction generator synchronous with an external alternating current power system, and with the photo voltaicmore » power synchronized therewith by commutation.« less
Research on Thermodynamic Parameters of a Micro-Turbine for Standalone Cogeneration
NASA Astrophysics Data System (ADS)
Chekardovskiy, M. N.; Chekardovskiy, S. M.; Chekardovskaya, I. A.; Mihajlenko, A. I.
2016-10-01
In order to advance the heating and hot water systems in the Russian Federation we need to address the problem of introducing new sources of heat and electric energy. The paper overviews the relationship between the reliability, efficiency and diagnostic maintenance of the GMTU, the studies of rated and operating conditions of the GMTU, the development and improvement of methods for calculating rated and operating thermodynamic and diagnostic parameter of the unit. This resulted in developing a passport of thermodynamic parameters that can be compared to the parameters of the same units when they operate for the purpose of diagnosing their state.
Exploring classroom life through cogenerative dialogues
NASA Astrophysics Data System (ADS)
Higgins, Joanna; Bonne, Linda
2014-03-01
In response to Shady's reflection on his experience as a teacher-researcher in which he explored different cogen structures, we consider fluid participant configurations using cogens as a research method to provide insights into classroom life. Our cogens illuminated the role of symbolic, cultural and social capital in student-teacher alignments that changed across different classroom situations. In Shady's study, as well as our own, respectful student-teacher relationships that involved the teacher and students first establishing common social capital, enabled the teacher to "be in with" the students, and vice versa. We raise questions about how the structure of cogens might affect the nature of the dialogue that is cogenerated.
Energy recovery with turboexpander processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holm, J.
1985-07-01
Although the primary function of turboexpanders has been to provide efficient, low-temperature refrigeration, the energy thus extracted has also been an important additional feature. Today, turboexpanders are proven reliable and used widely in the following applications discussed in this article: industrial gases; natural gas (NG) processing; production of liquefied natural gas (LNG); flashing hydrocarbon liquids; NG pressure letdown energy recovery; oilfield cogeneration; and recovery of energy from waste heat. Turboexpander applications for energy conservation resulted because available turboexpanders have the required high-performance capabilities and reliability. At the same time, the development of these energy conservation practices and processes helped furthermore » improve turboexpanders.« less
Gyroharmonic conversion experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirshfield, J. L.; LaPointe, M. A.; Yale University, New Haven, Connecticut 06511
1999-05-07
Generation of high power microwaves has been observed in experiments where a 250-350 kV, 20-30 A electron beam accelerated in a cyclotron autoresonance accelerator (CARA) passes through a cavity tuned gyroharmonic) and at 8.6 GHz (3rd harmonic) will be described. Theory indicates that high conversion efficiency can be obtained for a high quality beam injected into CARA, and when mode competition can be controlled. Comparisons will be made between the experiments and theory. Planned 7th harmonic experiments will also be described, in which phase matching between the TE-72 mode at 20 GHz, and the TE-11 mode at 2.86 GHz, allowsmore » efficient 20 GHz co-generation within the CARA waveguide itself.« less
Environmentally conscious alternative energy production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kutz, M.
This fourth volume of the series describes and compares the environmental and economic impacts of renewable and conventional power generation technologies. Chapter heading are: Economic comparisons of power generation technologies (Todd Nemec); Solar energy applications (Jan F. Kreider); Fuel cells (Matthew W. Mench); Geothermal resources and technology: an introduction (Peter D. Blair); Wind power generation (Todd Nemec); Cogeneration (Jerald Caton); Hydrogen energy (Elias K. Stefanakos, Yogi Goswami, S.S. Srinivasan, and J.T. Wolan); Clean power generation from coal (Prabir Basu and James Butler); and Using waste heat from power plants (Herbert A. Ingley). The chapter on clean coal power generation frommore » coal has been abstracted separately on the Coal Abstracts database. 2 apps.« less
Competitive position of natural gas: industrial baking. Topical report, December 1986-January 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minsker, B.S.; Salama, S.Y.
To quantify the competitive position of natural gas in industrial baking, market profiles were developed to define current technologies (single lap, tunnel, and Lanham ovens are predominant) and to characterize the applications and use of each technology in industrial baking. Important cost and performance parameters were identified and validated through interviews with industry representatives. Two areas of research that could improve technologies' effectiveness are advanced burner controls activated based on oven load that could reduce product loss, the largest coast associated with the oven, and cogeneration, which could penetrate the baking market if the high capital costs associated with existingmore » equipment could be reduced.« less
Isolated Operation at Hachinohe Micro-Grid Project
NASA Astrophysics Data System (ADS)
Takano, Tomihiro; Kojima, Yasuhiro; Temma, Koji; Simomura, Masaru
To meet the global warming, renewable energy sources like wind, solar and biomass generations are dramatically increasing. Cogeneration systems are also ever-growing to save consumers' energy costs among factories, buildings and homes where lots of thermal loads are expected. According to these dispersed generators growth, their negative impacts to commercial power systems quality become non-negligible, because their unstable output causes network voltage and frequency fluctuation. Micro-grid technology comes to the front to solve the problem and many demonstrative field tests are now going all over the world. This paper presents the control paradigm and its application to Hachinohe micro-gird project, especially focusing on the power quality at isolated operation on which strict condition is imposed.
Integrated gasifier combined cycle polygeneration system to produce liquid hydrogen
NASA Technical Reports Server (NTRS)
Burns, R. K.; Staiger, P. J.; Donovan, R. M.
1982-01-01
An integrated gasifier combined cycle (IGCC) system which simultaneously produces electricity, process steam, and liquid hydrogen was evaluated and compared to IGCC systems which cogenerate electricity and process steam. A number of IGCC plants, all employing a 15 MWe has turbine and producing from 0 to 20 tons per day of liquid hydrogen and from 0 to 20 MWt of process steam were considered. The annual revenue required to own and operate such plants was estimated to be significantly lower than the potential market value of the products. The results indicate a significant potential economic benefit to configuring IGCC systems to produce a clean fuel in addition to electricity and process steam in relatively small industrial applications.
NASA Technical Reports Server (NTRS)
Habib-Agahi, H.
1981-01-01
Market assessment, refined with analysis disaggregated from a national level to the regional level and to specific market applications, resulted in more accurate and detailed market estimates. The development of an integrated set of computer simulations, coupled with refined market data, allowed progress in the ability to evaluate the worth of solar thermal parabolic dish systems. In-depth analyses of both electric and thermal market applications of these systems are described. The following market assessment studies were undertaken: (1) regional analysis of the near term market for parabolic dish systems; (2) potential early market estimate for electric applications; (3) potential early market estimate for industrial process heat/cogeneration applications; and (4) selection of thermal and electric application case studies for fiscal year 1981.
NASA Astrophysics Data System (ADS)
Giaconia, Alberto; Montagnino, Fabio; Paredes, Filippo; Donato, Filippo; Caputo, Giampaolo; Mazzei, Domenico
2017-06-01
CSP technologies can be applied for distributed energy production, on small-medium plants (on the 1 MW scale), to satisfy the needs of local communities, buildings and districts. In this perspective, reliable, low-cost, and flexible small/medium multi-generative CSP plants should be developed. Four pilot plants have been built in four Mediterranean countries (Cyprus, Egypt, Jordan, and Italy) to demonstrate the approach. In this paper, the plant built in Italy is presented, with specific innovations applied in the linear Fresnel collector design and the Thermal Energy Storage (TES) system, based on a single the use of molten salts but specifically tailored for small scale plants.
Huntingtin gene evolution in Chordata and its peculiar features in the ascidian Ciona genus
Gissi, Carmela; Pesole, Graziano; Cattaneo, Elena; Tartari, Marzia
2006-01-01
Background To gain insight into the evolutionary features of the huntingtin (htt) gene in Chordata, we have sequenced and characterized the full-length htt mRNA in the ascidian Ciona intestinalis, a basal chordate emerging as new invertebrate model organism. Moreover, taking advantage of the availability of genomic and EST sequences, the htt gene structure of a number of chordate species, including the cogeneric ascidian Ciona savignyi, and the vertebrates Xenopus and Gallus was reconstructed. Results The C. intestinalis htt transcript exhibits some peculiar features, such as spliced leader trans-splicing in the 98 nt-long 5' untranslated region (UTR), an alternative splicing in the coding region, eight alternative polyadenylation sites, and no similarities of both 5' and 3'UTRs compared to homologs of the cogeneric C. savignyi. The predicted protein is 2946 amino acids long, shorter than its vertebrate homologs, and lacks the polyQ and the polyP stretches found in the the N-terminal regions of mammalian homologs. The exon-intron organization of the htt gene is almost identical among vertebrates, and significantly conserved between Ciona and vertebrates, allowing us to hypothesize an ancestral chordate gene consisting of at least 40 coding exons. Conclusion During chordate diversification, events of gain/loss, sliding, phase changes, and expansion of introns occurred in both vertebrate and ascidian lineages predominantly in the 5'-half of the htt gene, where there is also evidence of lineage-specific evolutionary dynamics in vertebrates. On the contrary, the 3'-half of the gene is highly conserved in all chordates at the level of both gene structure and protein sequence. Between the two Ciona species, a fast evolutionary rate and/or an early divergence time is suggested by the absence of significant similarity between UTRs, protein divergence comparable to that observed between mammals and fishes, and different distribution of repetitive elements. PMID:17092333
Rinaldi, Caterina; Masoni, Paolo; Salvati, Fabio; Tolve, Pietro
2015-07-01
Automotive Shredder Residue (ASR) is a problematic waste material remaining after shredding and recovery processes of end-of-life vehicles (ELVs). Its heterogeneous grain size and composition make difficult its recovery or disposal. Although ASR accounts for approximately 20% to 25% of the weight of an ELV, the European Union (EU)'s ELV Directive (2000/53/EC) requires that by 2015 a minimum 95% of the weight of an ELV must be reused or recovered, including a 10% weight energy recovery. The quantity of ASR is relevant: Approximately 2.4 million tons are generated in the EU each year and most of it is sent to landfills. This article describes a life cycle model of the "TEKNE-Fluff" process designed to make beneficial use of ASR that is based on the results of an experimental pilot plant for pyro-gasification, combustion, cogeneration, and emissions treatment of ASR. The goal of the research was the application of life cycle assessment (LCA) methodology to identify the environmental hot spots of the "TEKNE system" and use scenario analysis to check solutions to improve its environmental profile, supporting the design and industrialization process. The LCA was conducted based on data modeled from the experimental campaign. Moreover, different scenarios on shares of electricity and thermal energy produced by the cogeneration system and alternative treatment processes for the waste produced by the technology were compared. Despite the limitation of the research (results based on scaling up experimental data by modeling), impact assessment results are promising and sufficiently robust, as shown by Monte Carlo analysis. The TEKNE technology may become an interesting solution for the problem of ASR management: Besides representing an alternative to landfill disposal, the energy produced could avoid significant impacts on fossil resources depletion (a plant of 40,000 tons/y capacity could produce ∼ 147,000 GJ/yr, covering the annual need of ∼ 13,500 households). © 2015 SETAC.
Low NO[sub x], cogeneration process and system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bell, R.D.
1993-07-06
A process is described for low NO[sub x] cogeneration to produce electricity and useful heat, which comprises: providing fuel and oxygen to an internal combustion engine connected to drive an electric generator, to thereby generate electricity; recovering from said engine an exhaust stream including elevated NO[sub x] levels and combined oxygen; adding to said exhaust stream sufficient fuel to create a fuel-rich mixture, the quantity of fuel being sufficient to react with the available oxygen and reduce the NO[sub x], in said exhaust stream; providing said fuel-enriched exhaust stream to a thermal reactor and reacting therein said fuel, NO[sub x]more » and available oxygen, to provide a heated oxygen-depleted stream; cooling said oxygen-depleted stream by passing same through a first heat exchanger; adding conversion oxygen to said cooled stream from said heat exchanger, and passing the cooled oxygen-augmented stream over a first catalyst bed operated at a temperature of about 750 to 1,250 F under overall reducing conditions, the quantity of conversion oxygen added being in stoichiometric excess of the amount of NO[sub x], but less than the amount of combustibles; whereby the NO[sub x] is first oxidized to NO[sub 2], and then the NO[sub 2] is reduced by the excess combustibles; cooling said stream from said first catalyst bed to a temperature of about 450 to 650 F by passing said stream through a second heat exchanger; adding air to the resulting cooled stream to produce a further cooled stream at a temperature of about 400 to 600 F, and having a stoichiometric excess of oxygen; and passing said stream having said stoichiometric excess of oxygen over an oxidizing catalyst bed at said temperature of 400 to 600 F to oxidize remaining excess combustibles, to thereby provide an effluent stream having environmentally safe characteristics.« less
NASA Astrophysics Data System (ADS)
Braun, Robert Joseph
The advent of maturing fuel cell technologies presents an opportunity to achieve significant improvements in energy conversion efficiencies at many scales; thereby, simultaneously extending our finite resources and reducing "harmful" energy-related emissions to levels well below that of near-future regulatory standards. However, before realization of the advantages of fuel cells can take place, systems-level design issues regarding their application must be addressed. Using modeling and simulation, the present work offers optimal system design and operation strategies for stationary solid oxide fuel cell systems applied to single-family detached dwellings. A one-dimensional, steady-state finite-difference model of a solid oxide fuel cell (SOFC) is generated and verified against other mathematical SOFC models in the literature. Fuel cell system balance-of-plant components and costs are also modeled and used to provide an estimate of system capital and life cycle costs. The models are used to evaluate optimal cell-stack power output, the impact of cell operating and design parameters, fuel type, thermal energy recovery, system process design, and operating strategy on overall system energetic and economic performance. Optimal cell design voltage, fuel utilization, and operating temperature parameters are found using minimization of the life cycle costs. System design evaluations reveal that hydrogen-fueled SOFC systems demonstrate lower system efficiencies than methane-fueled systems. The use of recycled cell exhaust gases in process design in the stack periphery are found to produce the highest system electric and cogeneration efficiencies while achieving the lowest capital costs. Annual simulations reveal that efficiencies of 45% electric (LHV basis), 85% cogenerative, and simple economic paybacks of 5--8 years are feasible for 1--2 kW SOFC systems in residential-scale applications. Design guidelines that offer additional suggestions related to fuel cell-stack sizing and operating strategy (base-load or load-following and cogeneration or electric-only) are also presented.
Bellini, Marco; Bevilacqua, Manuela; Filippi, Jonathan; Lavacchi, Alessandro; Marchionni, Andrea; Miller, Hamish A; Oberhauser, Werner; Vizza, Francesco; Annen, Samuel P; Grützmacher, H
2014-09-01
Organometallic fuel cells catalyze the selective electrooxidation of renewable diols, simultaneously providing high power densities and chemicals of industrial importance. It is shown that the unique organometallic complex [Rh(OTf)(trop2NH)(PPh3)] employed as molecular active site in an anode of an OMFC selectively oxidizes a number of renewable diols, such as ethylene glycol , 1,2-propanediol (1,2-P), 1,3-propanediol (1,3-P), and 1,4-butanediol (1,4-B) to their corresponding mono-carboxylates. The electrochemical performance of this molecular catalyst is discussed, with the aim to achieve cogeneration of electricity and valuable chemicals in a highly selective electrooxidation from diol precursors. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Total cost of 46-Mw Borax cogen system put at $30M
DOE Office of Scientific and Technical Information (OSTI.GOV)
de Biasi, V.
1983-03-01
The cogeneration system, designed around a W-251B gas turbine power plant exhausting into a Deltak waste heat boiler to produce ''free'' process steam from the gas turbine exhaust, is discussed. The design includes water injection for NO/sub x/ control, self-cleaning inlet air filters, evaporative coolers, supercharger, and supplementary firing of the waste heat boiler. Once the system is operational Borax will be able to generate all of the electricity needed for on-site operations and a large share of process steam needs--plus still have 22-23 Mw surplus electric power to sell, so that the installation should pay for itself in lessmore » than 5 years of service.« less
Thermoelectric Energy Conversion: Future Directions and Technology Development Needs
NASA Technical Reports Server (NTRS)
Fleurial, Jean-Pierre
2007-01-01
This viewgraph presentation reviews the process of thermoelectric energy conversion along with key technology needs and challenges. The topics include: 1) The Case for Thermoelectrics; 2) Advances in Thermoelectrics: Investment Needed; 3) Current U.S. Investment (FY07); 4) Increasing Thermoelectric Materials Conversion Efficiency Key Science Needs and Challenges; 5) Developing Advanced TE Components & Systems Key Technology Needs and Challenges; 6) Thermoelectrics; 7) 200W Class Lightweight Portable Thermoelectric Generator; 8) Hybrid Absorption Cooling/TE Power Cogeneration System; 9) Major Opportunities in Energy Industry; 10) Automobile Waste Heat Recovery; 11) Thermoelectrics at JPL; 12) Recent Advances at JPL in Thermoelectric Converter Component Technologies; 13) Thermoelectrics Background on Power Generation and Cooling Operational Modes; 14) Thermoelectric Power Generation; and 15) Thermoelectric Cooling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Speaking before the FERC during the Spring, 1987 PURPA Hearings, Dr. Thomas A.V. Cassel, president of the Philadelphia, Pennsylvania-based Reading Energy Group, testified on the role PURPA has played in the development of the nation's solid fuel resource. Reading's Energy Group has in excess of $150 million of cogeneration assets under construction. These projects represent more than 65 MW and are fired by solid fuels which, prior to PURPA's enactment, were considered to be valueless waste and were overlooked by the electric utility industry. These plants will burn lignite and culm. Because of PURPA, culm will soon be eliminated asmore » an eyesore and source of river pollution, and, at the same time, will help revitalize depressed mining areas.« less
NASA Astrophysics Data System (ADS)
1982-05-01
The technical and economic feasibility of producing motor fuel alcohol from corn in a 100 million gallon per year plant to be constructed in Myrtle Grove, Louisiana is evaluated. The evaluation includes a detailed process design using proven technology, a capital cost estimate for the plant, a detailed analysis of the annual operating cost, a market study, a socioeconomic, environmental, health and safety analysis, and a complete financial analysis. Several other considerations for production of ethanol were evaluated including: cogeneration and fuel to be used in firing the boilers; single by-products vs. multiple by-products; and use of boiler flue gas for by-product drying.
Task 6 -- Advanced turbine systems program conceptual design and product development
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-01-10
The Allison Engine Company has completed the Task 6 Conceptual Design and Analysis of Phase 2 of the Advanced Turbine System (ATS) contract. At the heart of Allison`s system is an advanced simple cycle gas turbine engine. This engine will incorporate components that ensure the program goals are met. Allison plans to commercialize the ATS demonstrator and market a family of engines incorporating this technology. This family of engines, ranging from 4.9 MW to 12 MW, will be suitable for use in all industrial engine applications, including electric power generation, mechanical drive, and marine propulsion. In the field of electricmore » power generation, the engines will be used for base load, standby, cogeneration, and distributed generation applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rametta, A.J.; Shinn, R.A.
1985-08-01
Pennsylvania entered into third-party financing for energy conservation projects because the state has too many competing priorities to fully invest in all the energy savings potential that public buildings represent. Conservation, fuel conversion, and cogeneration opportunities could reduce the state's $100 million energy bill by $20-30 million, and the state felt it could not continue to defer this savings potential. The authors describe the practical experience Pennsylvania gained in the process as well as the criteria and results of ranking state facilities as potential candidates. They identify the key features of the contractor selection process, and emphasize the need formore » competitive bidding and the advisability of a two-phase approach for larger buildings.« less
A natural-gas fuel processor for a residential fuel cell system
NASA Astrophysics Data System (ADS)
Adachi, H.; Ahmed, S.; Lee, S. H. D.; Papadias, D.; Ahluwalia, R. K.; Bendert, J. C.; Kanner, S. A.; Yamazaki, Y.
A system model was used to develop an autothermal reforming fuel processor to meet the targets of 80% efficiency (higher heating value) and start-up energy consumption of less than 500 kJ when operated as part of a 1-kWe natural-gas fueled fuel cell system for cogeneration of heat and power. The key catalytic reactors of the fuel processor - namely the autothermal reformer, a two-stage water gas shift reactor and a preferential oxidation reactor - were configured and tested in a breadboard apparatus. Experimental results demonstrated a reformate containing ∼48% hydrogen (on a dry basis and with pure methane as fuel) and less than 5 ppm CO. The effects of steam-to-carbon and part load operations were explored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thumann, A.
This book presents the detailed guidance on how to effectively purchase deregulated energy, based on first-hand reports from many of the nation`s most knowledgeable experts. It is designed to provide the kind of practical advice needed by professionals who are responsible for making energy purchasing decisions. The book gives a ten-step program to guide building owners in purchasing decision making, a state-by-state retail competition update, and guidelines for buying electricity and natural gas over the worldwide web. Other topics include contract renegotiation strategies, an assessment of power pools, the role of aggregators in the energy market, real time pricing issues,more » where cogeneration fits within today`s marketplace, and lessons learned from deregulation experiences in Scandinavia and England.« less
Study on Improving Partial Load by Connecting Geo-thermal Heat Pump System to Fuel Cell Network
NASA Astrophysics Data System (ADS)
Obara, Shinya; Kudo, Kazuhiko
Hydrogen piping, the electric power line, and exhaust heat recovery piping of the distributed fuel cells are connected with network, and operational planning is carried out. Reduction of the efficiency in partial load is improved by operation of the geo-thermal heat pump linked to the fuel cell network. The energy demand pattern of the individual houses in Sapporo was introduced. And the analysis method aiming at minimization of the fuel rate by the genetic algorithm was described. The fuel cell network system of an analysis example assumed connecting the fuel cell co-generation of five houses. When geo-thermal heat pump was introduced into fuel cell network system stated in this paper, fuel consumption was reduced 6% rather than the conventional method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreutz, Thomas G; Ogden, Joan M
2000-07-01
In the final report, we present results from a technical and economic assessment of residential scale PEM fuel cell power systems. The objectives of our study are to conceptually design an inexpensive, small-scale PEMFC-based stationary power system that converts natural gas to both electricity and heat, and then to analyze the prospective performance and economics of various system configurations. We developed computer models for residential scale PEMFC cogeneration systems to compare various system designs (e.g., steam reforming vs. partial oxidation, compressed vs. atmospheric pressure, etc.) and determine the most technically and economically attractive system configurations at various scales (e.g., singlemore » family, residential, multi-dwelling, neighborhood).« less
Assessment of industrial applications for fuel cell cogeneration systems
NASA Technical Reports Server (NTRS)
Stickles, R. P.; Oneill, J. K.; Smith, E. H.
1978-01-01
The fuel cell energy systems are designed with and without a utility connection for emergency back-up power. Sale of electricity to the utility during periods of low plant demand is not considered. For each of the three industrial applications, conceptual designs were also developed for conventional utility systems relying on purchased electric power and fossil-fired boilers for steam/hot water. The capital investment for each energy system is estimated. Annual operating costs are also determined for each system. These cost estimates are converted to levelized annual costs by applying appropriate economic factors. The breakeven electricity price that would make fuel cell systems competitive with the conventional systems is plotted as a function of naphtha price. The sensitivity of the breakeven point to capital investment and coal price is also evaluated.
Gyroharmonic conversion experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirshfield, J.L.; LaPointe, M.A.; Ganguly, A.K.
1999-05-01
Generation of high power microwaves has been observed in experiments where a 250{endash}350 kV, 20{endash}30 A electron beam accelerated in a cyclotron autoresonance accelerator (CARA) passes through a cavity tuned gyroharmonic) and at 8.6 GHz (3rd harmonic) will be described. Theory indicates that high conversion efficiency can be obtained for a high quality beam injected into CARA, and when mode competition can be controlled. Comparisons will be made between the experiments and theory. Planned 7th harmonic experiments will also be described, in which phase matching between the TE-72 mode at 20 GHz, and the TE-11 mode at 2.86 GHz, allowsmore » efficient 20 GHz co-generation within the CARA waveguide itself. {copyright} {ital 1999 American Institute of Physics.}« less
NASA Astrophysics Data System (ADS)
Laptev, A. G.; Basharov, M. M.; Farakhova, A. I.
2013-09-01
The process through which small droplets contained in emulsions are physically coagulated on the surface of random packing elements is considered. The theory of turbulent migration of a finely dispersed phase is used for determining the coagulation efficiency. Expressions for calculating coagulation efficiency and turbulent transfer rate are obtained by applying models of a turbulent boundary layer. An example of calculating the enlargement of water droplets in hydrocarbon medium represented by a wide fraction of light hydrocarbons (also known as natural gas liquid) is given. The process flowchart of a system for removing petroleum products from effluent waters discharged from the Kazan TETs-1 cogeneration station is considered. Replacement of the mechanical filter by a thin-layer settler with a coagulator is proposed.
NASA Astrophysics Data System (ADS)
Vivekananda, S.; Raghunath, P.; Bhanuprakash, K.; Srinivas, R.; Trikoupis, Moschoula A.; Terlouw, Johan K.
2000-12-01
Electron ionization of rhodanine yields iminothiosulfine ions H- N C- S- Srad + , 1brad + , which readily communicate with the higher energy cyclic isomer H- N CS2rad + , 1arad + . CBS-QB3 and G AUSSIAN-2 model chemistries predict that one electron reduction reverses the stability order but that the (singlet) neutrals remain connected via a negligible energy barrier. Neutralization-reionization (NR) experiments demonstrate that singlet 1a and its heterocumulene isomer 1b are stable species in the gas-phase. However, the co-generated triplet species readily dissociate into 3S2rad + + HNC. Confirmatory experimental evidence comes from charge reversal (CR) and NR experiments on the cyclic anion H- N CS2rad - , 1arad - .
Advanced batteries for load-leveling - The utility perspective on system integration
NASA Astrophysics Data System (ADS)
Delmonaco, J. L.; Lewis, P. A.; Roman, H. T.; Zemkoski, J.
1982-09-01
Rechargeable battery systems for applications as utility load-leveling units, particularly in urban areas, are discussed. Particular attention is given to advanced lead-acid, zinc-halogen, sodium-sulfer, and lithium-iron sulfide battery systems, noting that battery charging can proceed at light load hours and requires no fuel on-site. Each battery site will have a master site controller and related subsystems necessary for ensuring grid-quality power output from the batteries and charging when feasible. The actual interconnection with the grid is envisioned as similar to transmission, subtransmission, or distribution systems similar to cogeneration or wind-derived energy interconnections. Analyses are presented of factors influencing the planning economics, impacts on existing grids through solid-state converters, and operational and maintenance considerations. Finally, research directions towards large scale battery implementation are outlined.
Reformation of PURPA contracts: Strategies for success in power marketing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scalzo, P.J.
With the passage of the Energy Policy Act of 1992, real competition entered into the world of electric utilities. A slide presentations is given on reformation of Public Utility Regulatory Policies Act (PURPA) Contracts for success in power marketing strategies. Two ways to compete: Be the least cost provider or add value and `sell hard`. The PURPA vision was to increase efficiency in power generation, utilize renewable or waste fuels, and bolster the independent producers. Cogenerators and small power producers qualified. Utility planners predicted, avoided cost, utility loads, and oil and gas prices to increase. However, avoided costs, and oilmore » and gase prices declined. Two scenarios are discussed for contract reformation: Contract buyouts, and renegotiation of contracts. Options for for dealing with existing fuel agreements are presented.« less
Data on development of new energy technologies
NASA Astrophysics Data System (ADS)
1994-03-01
The paper compiles data on the trend of development of new energy technologies into a book. By category, renewable energy is solar energy, wind power generation, geothermal power generation, ocean energy, and biomass. As a category of fuel form conversion, cited are coal liquefaction/gasification, coal gasification combined cycle power generation, and natural gas liquefaction/decarbonization. The other categories are cogeneration by fuel cell and ceramic gas turbine, district heat supply system, power load leveling technology, transportation-use substitution-fuel vehicle, and others (Stirling engine, superconducting power generator, etc.). The data are systematically compiled on essential principles, transition of introduction, objectives of introduction, status of production, cost, development schedule, performance, etc. The paper also deals with the related legislation system, developmental organizations, and a menu for power companies' buying surplus power.
Advancement of Double Effect Absorption Cycle by Input of Low Temperature Waste Heat
NASA Astrophysics Data System (ADS)
Kojima, Hiroshi; Edera, Masaru; Nakamura, Makoto; Oka, Masahiro; Akisawa, Atsushi; Kashiwagi, Takao
Energy conservation is becoming important for global environmental protection. New simple techniques of more efficient1y using the waste heat of gas co-generation systems for refrigerationare required. In first report, a new method of using the low temperature waste heat for refrigeration was proposed, and the basic characteristics of the promising methods of recovering waste heat were c1arified. In this report, the more detailed simulation model of the series flow type double effect absorption refrigerator with auxiliary heat exchanger was constructed and the static characteristics were investigated. Then experiments on this advanced absorption refrigerator were carried out, and the results of the calculation and experiments were compared and discussed. Moreover, the betterment of the simulation model of this advanced absorption refrigerator was carried out.
NASA Astrophysics Data System (ADS)
Viola, J.; Aceros, C.
2016-07-01
Smart Grids are a technology that can be used to implement a sustainable energy scheme of a country. Therefore, this paper proposes the development of a prospective analysis of Smart Grids as a tool to ensure energetic security in Colombia in 2050. Using LEAP software, a base scenario for Colombian energy demand has developed according to current policies, with a time horizon from 2012 to 2050. The energy analysis is based on three scenarios, taking into account the impact of cogeneration in the residential and industrial sector using renewable energy and the power quality indicators. The results show that the implementation of Smart Grids generate energy savings and increasing the coverage of the national electricity system, ensuring energetic security of the country by 2050.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-07-01
The module presents an overview of regulations applicable to generators of hazardous waste. It defines the terms `generator` and `co-generator,` and lists the three classes of generators, outlines the different generation and accumulation limits, and provides specific regulatory and CFR citations. It defines episodic generation and explains the use of EPA identification numbers and manifests. It outlines the accumulation standards, defines `empty tank` and `start time` for waste accumulation purposes, and identifies regulations pertaining to accumulation in tanks, containers, containment buildings, and on drip pads. It defines `satellite accumulation` and provides applicable federal register citations. It cites the CFR sectionmore » covering recordkeeping and reporting requirements for generators. It explains how to obtain copies of notification forms and manifests.« less
H[sub 2]/Cl[sub 2] fuel cells for power and HCl production - chemical cogeneration
Gelb, A.H.
1991-08-20
A fuel cell for the electrolytic production of hydrogen chloride and the generation of electric energy from hydrogen and chlorine gas is disclosed. In typical application, the fuel cell operates from the hydrogen and chlorine gas generated by a chlorine electrolysis generator. The hydrogen chloride output is used to maintain acidity in the anode compartment of the electrolysis cells, and the electric energy provided from the fuel cell is used to power a portion of the electrolysis cells in the chlorine generator or for other chlorine generator electric demands. The fuel cell itself is typically formed by a passage for the flow of hydrogen chloride or hydrogen chloride and sodium chloride electrolyte between anode and cathode gas diffusion electrodes. 3 figures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marshall, D.K.
1996-12-31
Electricity production from biomass fuel has been hailed in recent years as an environmentally acceptable energy source that delivers on its promise of economically viable renewable energy. A Wall Street Journal article from three years ago proclaimed wood to be {open_quotes}moving ahead of costly solar panels and wind turbines as the leading renewable energy alternative to air-fouling fossils fuels and scary nuclear plants.{close_quotes} Biomass fuel largely means wood; about 90% of biomass generated electricity comes from burning waste wood, the remainder from agricultural wastes. Biomass power now faces an uncertain future. The maturing of the cogeneration and independent power plantmore » market, restructuring of the electric industry, and technological advances with power equipment firing other fuels have placed biomass power in a competitive disadvantage with other power sources.« less
NASA Astrophysics Data System (ADS)
Ramadan, Omar Barka Ab
A novel low NOx conical wire-mesh duct burner was designed, built and tested in the present research. This thesis documents the design process and the in-depth evaluation of this novel duct burner for the development of a more efficient micro-cogeneration unit. This duct burner provides the thermal energy necessary to raise the microturbine exhaust gases temperature to increase the heat recovery capability. The duct burner implements both lean-premixed and surface combustion techniques to achieve low NOx and CO emissions. The design of the duct burner was supported by a qualitative flow visualization study for the duct burner premixer to provide insight into the premixer flow field (mixing process). Different premixer geometries were used to control the homogeneity of the fuel-oxidant mixture at the exit of the duct burner premixer. Laser sheet illumination (LSI) technique was used to capture images of the mixing process, for each configuration studied. A quasi-quantitative analysis technique was developed to rank the different premixer geometries in terms of mixing effectiveness. The premixer geometries that provided better mixing were selected and used for the combustion tests. The full-scale gas-fired duct burner was installed in the exhaust duct of a micro-cogeneration unit for the evaluation. Three wire-mesh burners with different pressure drops were used. Each burner has a conical shape made from FeCrAL alloy mat and was designed based on a heat release per unit area of 2500 kW/m2 and a total heat release of 240kW at 100 percent excess air. The local momentum of the gaseous mixture introduced through the wire-mesh was adjusted so that the flame stabilized outside the burner mesh (surface combustion). Cold flow tests (i.e., the duct burner was off, but the microturbine was running) were conducted to measure the effect of different duct burner geometrical parameters on flow split between the combustion zone and the bypass channel, and on pressure drop across the duct burner. A considerable amount of detailed parametric experimental data was collected to investigate the performance characteristics of the duct burner. The variables studied (firing rate, mass flow ratio, conical burner pressure drop, blockage ratio, conical burner shield length, premixer geometry and inlet conditions) were all found to play an important role on emissions (NOx and CO), overall duct burner pressure drop and flame stability. The range of firing rates at which surface combustion was maintained for the duct burner was defined by direct observation of the burner surface and monitoring of the temperature in the combustion zone. Flame images were captured for qualitative assessment. The combustion tests results presented in this thesis proved that the design procedures that were implemented to design this novel microturbine conical wire-mesh duct burner were successful. During the course of the combustion tests, the duct burner displayed stable, low emissions operation throughout the surface firing rate range of 148 kW to 328 kW (1574 kW/m 2 to 3489 kW/m2). Emissions of less than 5 ppm (corrected to 15 percent 02) for NOx and CO emissions were recorded, while the duct burner successfully raised the microturbine exhaust gases temperature from about 227°C to as high as 700°C. The overall duct burner pressure drop throughout was consistently below the design limit of 249 Pa.
Adoption and supply of a distributed energy technology
NASA Astrophysics Data System (ADS)
Strachan, Neil Douglas
2000-12-01
Technical and economic developments in distributed generation (DG) represent an opportunity for a radically different energy market paradigm, and potentially significant cuts in global carbon emissions. This thesis investigates DG along two interrelated themes: (1) Early adoption and supply of the DG technology of internal combustion (IC) engine cogeneration. (2) Private and social cost implications of DG for private investors and within an energy system. IC engine cogeneration of both power and heat has been a remarkable success in the Netherlands with over 5,000 installations and 1,500MWe of installed capacity by 1997. However, the technology has struggled in the UK with an installed capacity of 110Mwe, fulfilling only 10% of its large estimated potential. An investment simulation model of DG investments in the UK and Netherlands was used, together with analysis of site level data on all DG adoptions from 1985 through 1997. In the UK over 60% of the early installations were sized too small (<140kWe) to be economically attractive (suppliers made their money with maintenance contracts). In the Netherlands, most facilities were sized well above the economic size threshold of 100kWe (lower due to reduced operating and grid connection costs). Institutional players were key in improved sizing of DG. Aided by energy market and CO2 reduction regulatory policy, Dutch distributions utilities played a proactive role in DG. This involved joint ventures with engine cogen suppliers and users, offering improved electricity buy-back tariffs and lower connection costs. This has allowed flexible operation of distributed generation, especially in electricity sales to the grid. Larger units can be sized for on-site heat requirements with electricity export providing revenue and aiding in management of energy networks. A comparison of internal and external costs of three distributed and three centralized generation technologies over a range of heat to power ratios (HPR) was made. Micro-turbines were found to be the lowest cost technology, especially at higher heat loads. Engines are also very competitive providing their NOx and CO emissions are controlled. A cost optimization program was used to develop an optimal green-field supply mix for Florida and New York. (Abstract shortened by UMI.)
NASA Astrophysics Data System (ADS)
Osman, Ayat E.
Energy use in commercial buildings constitutes a major proportion of the energy consumption and anthropogenic emissions in the USA. Cogeneration systems offer an opportunity to meet a building's electrical and thermal demands from a single energy source. To answer the question of what is the most beneficial and cost effective energy source(s) that can be used to meet the energy demands of the building, optimizations techniques have been implemented in some studies to find the optimum energy system based on reducing cost and maximizing revenues. Due to the significant environmental impacts that can result from meeting the energy demands in buildings, building design should incorporate environmental criteria in the decision making criteria. The objective of this research is to develop a framework and model to optimize a building's operation by integrating congregation systems and utility systems in order to meet the electrical, heating, and cooling demand by considering the potential life cycle environmental impact that might result from meeting those demands as well as the economical implications. Two LCA Optimization models have been developed within a framework that uses hourly building energy data, life cycle assessment (LCA), and mixed-integer linear programming (MILP). The objective functions that are used in the formulation of the problems include: (1) Minimizing life cycle primary energy consumption, (2) Minimizing global warming potential, (3) Minimizing tropospheric ozone precursor potential, (4) Minimizing acidification potential, (5) Minimizing NOx, SO 2 and CO2, and (6) Minimizing life cycle costs, considering a study period of ten years and the lifetime of equipment. The two LCA optimization models can be used for: (a) long term planning and operational analysis in buildings by analyzing the hourly energy use of a building during a day and (b) design and quick analysis of building operation based on periodic analysis of energy use of a building in a year. A Pareto-optimal frontier is also derived, which defines the minimum cost required to achieve any level of environmental emission or primary energy usage value or inversely the minimum environmental indicator and primary energy usage value that can be achieved and the cost required to achieve that value.
An assessment of alternative fuel cell designs for residential and commercial cogeneration
NASA Technical Reports Server (NTRS)
Wakefield, R. A.
1980-01-01
A comparative assessment of three fuel cell systems for application in different buildings and geographic locations is presented. The study was performed at the NASA Lewis Center and comprised the fuel cell design, performance in different conditions, and the economic parameters. Applications in multifamily housing, stores and hospitals were considered, with a load of 10kW-1 MW. Designs were traced through system sizing, simulation/evaluation, and reliability analysis, and a computer simulation based on a fourth-order representation of a generalized system was performed. The cells were all phosphoric acid type cells, and were found to be incompatible with gas/electric systems and more favorable economically than the gas/electric systems in hospital uses. The methodology used provided an optimized energy-use pattern and minimized back-up system turn-on.
Introducing GEOPHIRES v2.0: Updated Geothermal Techno-Economic Simulation Tool: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckers, Koenraad J; McCabe, Kevin
This paper presents an updated version of the geothermal techno-economic simulation tool GEOPHIRES (GEOthermal Energy for Production of Heat and electricity (IR) Economically Simulated). GEOPHIRES combines reservoir, wellbore, surface plant and economic models to estimate the capital, and operation and maintenance costs, lifetime energy production, and overall levelized cost of energy of a geothermal plant. The available end-use options are electricity, direct-use heat and cogeneration. The main updates in the new version include conversion of the source code from FORTRAN to Python, the option to couple to an external reservoir simulator, updated cost correlations, and more flexibility in selecting themore » time step and number of injection and production wells. An overview of all the updates and two case-studies to illustrate the tool's new capabilities are provided in this paper.« less
Energy from Landfill Gas as an Example of Circular Economy
NASA Astrophysics Data System (ADS)
Ciuła, Józef; Gaska, Krzysztof; Generowicz, Agnieszka; Hajduga, Gabriela
2018-02-01
Landfill biogas becomes an important factor in elimination of fossil fuels as a result of fast- growing use of renewable energy sources. The article presents an analysis of operation of the plant where landfill biogas was utilized for energy production. The average annually (gross) productions of electric energy and heat at the plant were 1217 MWh and 1,789 MW, respectively. The average calorific value of biogas was 17 MJ/m3, which corresponds to 4,8 kW/m3. According to the measurements and actual readings acquired during operation of a cogeneration unit, it can be stated that the CHP system has been working within its average operation limits and still has some power reserves to utilize. Therefore, the authors concluded that a landfill can be operated both as a producer and a supplier of prosumer energy.
Advanced energy system program
NASA Astrophysics Data System (ADS)
Trester, K.
1987-06-01
The ogjectives are to design, develop, and demonstrate a natural-gas-fueled, highly recuperated, 50 kw Brayton-cycle cogeneration system for commercial, institutional, and multifamily residential applications. Recent marketing studies have shown that the Advanced Energy System (AES), with its many cost-effective features, has the potential to offer significant reductions in annual electrical and thermal energy costs to the consumer. Specific advantates of the system that result in low cost ownership are high electrical efficiency (34 percent, LHV), low maintenance, high reliability and long life (20 years). Significant technical features include: an integral turbogenerator with shaft-speed permanent magnet generator; a rotating assembly supported by compliant foil air bearings; a formed-tubesheet plate/fin recuperator with 91 percent effectiveness; and a bi-directional power conditioner to ultilize the generator for system startup. The planned introduction of catalytic combustion will further enhance the economic and ecological attractiveness.
Molten nitrate salt technology development
NASA Astrophysics Data System (ADS)
Carling, R. W.
1981-04-01
This paper presents an overview of the experimental programs underway in support of the Thermal Energy Storage for Solar Thermal Applications (TESSTA) program. The experimental programs are concentrating on molten nitrate salts which have been proposed as heat transfer and energy storage medium. The salt composition of greatest interest is drawsalt, nominally a 50-50 molar mixture of NaNO3 and KNO3 with a melting point of 220 C. Several technical uncertainties have been identified that must be resolved before nitrate based solar plants can be commercialized. Research programs at Sandia National Laboratories, universities, and industrial suppliers have been implemented to resolve these technical uncertainties. The experimental programs involve corrosion, decomposition, physical properties, and environmental cracking. Summaries of each project and how they impact central receiver applications such as the repowering/industrial retrofit and cogeneration program are presented.
Shafrir, Shai N; Romanofsky, Henry J; Skarlinski, Michael; Wang, Mimi; Miao, Chunlin; Salzman, Sivan; Chartier, Taylor; Mici, Joni; Lambropoulos, John C; Shen, Rui; Yang, Hong; Jacobs, Stephen D
2009-12-10
We report on magnetorheological finishing (MRF) spotting experiments performed on glasses and ceramics using a zirconia-coated carbonyl-iron (CI)-particle-based magnetorheological (MR) fluid. The zirconia-coated magnetic CI particles were prepared via sol-gel synthesis in kilogram quantities. The coating layer was approximately 50-100 nm thick, faceted in surface structure, and well adhered. Coated particles showed long-term stability against aqueous corrosion. "Free" nanocrystalline zirconia polishing abrasives were cogenerated in the coating process, resulting in an abrasive-charged powder for MRF. A viable MR fluid was prepared simply by adding water. Spot polishing tests were performed on a variety of optical glasses and ceramics over a period of nearly three weeks with no signs of MR fluid degradation or corrosion. Stable material removal rates and smooth surfaces inside spots were obtained.
NASA Technical Reports Server (NTRS)
1980-01-01
Present and future relatively small (30 MW) energy systems, such as solar thermal electric, photovoltaic, wind, fuel cell, storage battery, hydro, and cogeneration can help achieve national energy goals and can be dispersed throughout the distribution portion of an electric utility system. Based on current projections, it appears that dispersed storage and generation (DSG) electrical energy will comprise only a small portion, from 4 to 10 percent, of the national total by the end of this century. In general, the growth potential for DSG seems favorable in the long term because of finite fossil energy resources and increasing fuel prices. Recent trends, especially in the institutional and regulatory fields, favor greater use of the DSGs for the future.
Determination of the Prosumer's Optimal Bids
NASA Astrophysics Data System (ADS)
Ferruzzi, Gabriella; Rossi, Federico; Russo, Angela
2015-12-01
This paper considers a microgrid connected with a medium-voltage (MV) distribution network. It is assumed that the microgrid, which is managed by a prosumer, operates in a competitive environment and participates in the day-ahead market. Then, as the first step of the short-term management problem, the prosumer must determine the bids to be submitted to the market. The offer strategy is based on the application of an optimization model, which is solved for different hourly price profiles of energy exchanged with the main grid. The proposed procedure is applied to a microgrid and four different its configurations were analyzed. The configurations consider the presence of thermoelectric units that only produce electricity, a boiler or/and cogeneration power plants for the thermal loads, and an electric storage system. The numerical results confirmed the numerous theoretical considerations that have been made.
PURPA 210 avoided cost rates: Economic and implementation issues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devine, M.D.; Chartock, M.A.; Gunn, E.M.
The purpose of Section 210 of the Public Utilities Regulatory Policies Act (PURPA) was to promote the utilization of waste and renewable fuels and cogeneration processes for increasing electric power supplies. It represents a radical change in policy by allowing financially unregulated parties to generate power in ''qualifying facilities'' and by requiring utilities to purchase this power at the utilities' marginal (or ''avoided'') cost. PURPA 210 has clearly had a major impact as measured by the actual and proposed number of new qualifying facilities; however, implementation has been difficult due to the adversarial nature of the process for negotiating ormore » setting the avoided cost rates. This paper reviews the pertinent PURPA rules and regulations, analyzes the status of current avoided cost rates that have been established, and discusses implementation issues and options for resolving those issues.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-06-30
Research on the design, development, and testing of a high-temperature solid electrolyte (HTSOE) fuel cell is described in detail. Task 1 involves the development and refinement of fabrication processes for the porous support tube, fuel electrode, solid electrolyte, air electrode, and interconnection. Task 2 includes the life testing of cell components and the stack; task 3 involves the stack performance evaluation; task 4 includes demonstrating the reproducibility of 10 watt stacks. A cost, design and benefit study to evaluate the nature and worth of an industrial cogeneration application of the HTSOE fuel cell is underway. Here, promisng applications are nowmore » being considered, from which a single application has been selected as a basis for the study - an integrated aluminum production facility. (WHK)« less
NASA Astrophysics Data System (ADS)
1980-10-01
Present and future relatively small (30 MW) energy systems, such as solar thermal electric, photovoltaic, wind, fuel cell, storage battery, hydro, and cogeneration can help achieve national energy goals and can be dispersed throughout the distribution portion of an electric utility system. Based on current projections, it appears that dispersed storage and generation (DSG) electrical energy will comprise only a small portion, from 4 to 10 percent, of the national total by the end of this century. In general, the growth potential for DSG seems favorable in the long term because of finite fossil energy resources and increasing fuel prices. Recent trends, especially in the institutional and regulatory fields, favor greater use of the DSGs for the future.
NASA Astrophysics Data System (ADS)
Linkevics, O.; Ivanova, P.; Balodis, M.
2016-12-01
Intermittent generation (solar PV and wind energy) integration in power production portfolio as well as electricity price fluctuations have changed the running manner of conventional combined heat and power (CHP) plants: the shift from base load operation to running in cyclic modes. These cogeneration power plants are not adapted to new running conditions. The level of CHP plant flexibility should be improved to operate profitably and efficiently from both technical and fuel usage point of view. There are different ways to increase the flexibility of power plants. Before any improvements, the situation at power plants should be evaluated and the weakest points defined. In this publication, such measures are presented on Riga CHP-2 plant example: installation of heat storage tank; extension of operation rang; acceleration of start-ups.
Cryo-delivery Systems for the Co-transmission of Chemical and Electrical Power
NASA Astrophysics Data System (ADS)
Grant, Paul M.
2006-04-01
We present a novel concept for the simultaneous transport of chemical power in the form of natural gas or hydrogen in a cryogenic state along with the simultaneous transmission of electrical power over via superconductivity. This concept could impact future efforts to tap and deliver methane from distant geographic resources over conventional pipelines with part of the chemical potential energy converted directly to electricity at the wellhead and the remaining gas cooled cryogenically to increase volumetric density and provide the necessary support of a superconducting cable housed within the same packaging. As the fossil reserve becomes depleted, nuclear power plants would be constructed at the former remote wellhead sites to co-generate electricity and cryocooled hydrogen, the latter replacing natural gas and also serving to operate the already installed superconducting electrical service line.
NASA Astrophysics Data System (ADS)
Shimazaki, Yoichi
The aim of this study was to evaluate the refrigerating and air-conditioning technologies in cases of introducing both cogeneration system and energy network in food industrial park. The energy data of 14 factories were classified into steam, hot water, heating, cooling, refrigerating, freezing and electric power by interviews. The author developed a micro grid model based on linear programming so as to minimize the total system costs. The industrial park was divided into the 2,500 square meter mesh in order to take steam transport into consideration. Four cases were investigated. It was found that the electric power driven freezer was introduced compared with the ammonia absorption freezer. The ammonia absorption freezer was introduced in the factory that there is a little steam demand and large freezing demand at the same time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-01
The module presents an overview of regulations applicable to generators of hazardous waste. It defines the terms generator and co-generator. Lists the three classes of generators, outlines the different generation and accumulation limits, and provides specific regulatory and CFR citations. It also defines episodic generation. It explains the use of EPA identification numbers and manifests. It outlines the accumulation standards, defines empty tank and start time for waste accumulation purposes, and identifies regulations pertaining to accumulation in tanks, containers, containment buildings, and on drip pads. It defines satellite accumulation and provides applicable federal register citations. It cites the CFR sectionmore » covering recordkeeping and reporting requirements for generators. It explains how to obtain copies of notification forms and manifests.« less
Electric power supply and demand for the contiguous United States, 1981 - 1990
NASA Astrophysics Data System (ADS)
1981-07-01
The outlook for electric power supply and demand in the United States decade 1981 to 1990 is reviewed from the perspective of reliability and adequacy of service. Electric power supply adequacy as projected for the nine Regional Reliability Council areas of the contiguous United States is reported as well as interruptible load data reported by the Councils. cogeneration is discussed. Each of the 27 electric regions (sub-areas of the nine Council areas) in the contiguous US are studied. A glossary of terms is given. Appendices describe the Council structure, and include a copy of the ERA-411 Manual, which contains all the items to which the Councils were asked to respond. The utilities with included data, the Staff Report, Estimated Electric Demand and Supply for Summer 1981, Contiguous United States dated May 1981 are included.
A model biorefinery for avocado (Persea americana mill.) processing.
Dávila, Javier A; Rosenberg, Moshe; Castro, Eulogio; Cardona, Carlos A
2017-11-01
This research investigated and evaluated a biorefinery for processing avocado Hass variety into microencapsulated phenolic compounds extract, ethanol, oil and xylitol. Avocado was first characterized for its potential valuable compounds; then, the techno-economic and environmental aspects of the biorefinery were developed and finally the total production costs and potential environmental impact of the proposed biorefinery were investigated. Four scenarios of the biorefinery were evaluated with different extent of mass and energy integration as well as the incorporation of a cogeneration system. Results indicated that the main fatty acid in the pulp of the investigated avocado variety was oleic acid (50.96%) and that this fruit contained significant amount of holocellulose (52.88% and 54.36% in the peel and seed, respectively). Techno-economic and environmental assessment suggested an attractive opportunity for a biorefinery for complete utilization of the avocado fruit as well the importance of the level of integration. Copyright © 2017 Elsevier Ltd. All rights reserved.
An experimental aluminum-fueled power plant
NASA Astrophysics Data System (ADS)
Vlaskin, M. S.; Shkolnikov, E. I.; Bersh, A. V.; Zhuk, A. Z.; Lisicyn, A. V.; Sorokovikov, A. I.; Pankina, Yu. V.
2011-10-01
An experimental co-generation power plant (CGPP-10) using aluminum micron powder (with average particle size up to 70 μm) as primary fuel and water as primary oxidant was developed and tested. Power plant can work in autonomous (unconnected from industrial network) nonstop regime producing hydrogen, electrical energy and heat. One of the key components of experimental plant is aluminum-water high-pressure reactor projected for hydrogen production rate of ∼10 nm3 h-1. Hydrogen from the reactor goes through condenser and dehumidifier and with -25 °C dew-point temperature enters into the air-hydrogen fuel cell 16 kW-battery. From 1 kg of aluminum the experimental plant produces 1 kWh of electrical energy and 5-7 kWh of heat. Power consumer gets about 10 kW of electrical power. Plant electrical and total efficiencies are 12% and 72%, respectively.
The bright optical flash and afterglow from the gamma-ray burst GRB 130427A.
Vestrand, W T; Wren, J A; Panaitescu, A; Wozniak, P R; Davis, H; Palmer, D M; Vianello, G; Omodei, N; Xiong, S; Briggs, M S; Elphick, M; Paciesas, W; Rosing, W
2014-01-03
The optical light generated simultaneously with x-rays and gamma rays during a gamma-ray burst (GRB) provides clues about the nature of the explosions that occur as massive stars collapse. We report on the bright optical flash and fading afterglow from powerful burst GRB 130427A. The optical and >100-megaelectron volt (MeV) gamma-ray flux show a close correlation during the first 7000 seconds, which is best explained by reverse shock emission cogenerated in the relativistic burst ejecta as it collides with surrounding material. At later times, optical observations show the emergence of emission generated by a forward shock traversing the circumburst environment. The link between optical afterglow and >100-MeV emission suggests that nearby early peaked afterglows will be the best candidates for studying gamma-ray emission at energies ranging from gigaelectron volts to teraelectron volts.
Introducing GEOPHIRES v2.0: Updated Geothermal Techno-Economic Simulation Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckers, Koenraad J; McCabe, Kevin
This paper presents an updated version of the geothermal techno-economic simulation tool GEOPHIRES (GEOthermal energy for Production of Heat and electricity ('IR') Economically Simulated). GEOPHIRES combines engineering models of the reservoir, wellbores, and surface plant facilities of a geothermal plant with an economic model to estimate the capital and operation and maintenance costs, lifetime energy production, and overall levelized cost of energy. The available end-use options are electricity, direct-use heat, and cogeneration. The main updates in the new version include conversion of the source code from FORTRAN to Python, the option to import temperature data (e.g., measured or from stand-alonemore » reservoir simulator), updated cost correlations, and more flexibility in selecting the time step and number of injection and production wells. In this paper, we provide an overview of all the updates and two case studies to illustrate the tool's new capabilities.« less
Hitaveita Reykjavikur and the Nesjavellir geothermal co-generation power plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lund, J.W.
1996-11-01
When Ingolfur Arnarson sighted land on the voyage which would make him the first settler in Iceland, he threw the pillars of his high seat overboard and relied on the gods to direct him to where he should settle. His slaves found them washed ashore in a bay where {open_quotes}smoke{close_quotes} rose out of the ground. Therefore, they call it Reykjavik, {open_quotes}Smoky Bay.{close_quotes} But the smoke after which Iceland`s capital is named was not the result of a fire, but was rather steam rising from hot springs. Ancient records only mention the use of geothermal springs for washing and bathing. Themore » best known examples are the Thvottalaugar (Washing pools) in what is now Laugardalur in Reykjavik, and the hot pool where saga writer Snorri Sturluson bathed at his farm in Reykholt in western Iceland.« less
Ways to Improve Russian Coal-Fired Power Plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tumanovskii, A. G., E-mail: vti@vti.ru; Olkhovsky, G. G.
Coal is an important fuel for the electric power industry of Russia, especially in Ural and the eastern part of the country. It is fired in boilers of large (200 – 800 MW) condensing power units and in many cogeneration power plants with units rated at 50 – 180 MW. Many coal-fired power plants have been operated for more than 40 – 50 years. Though serviceable, their equipment is obsolete and does not comply with the current efficiency, environmental, staffing, and availability standards. It is urgent to retrofit and upgrade such power plants using advanced equipment, engineering and business ideas.more » Russian power-plant engineering companies have designed such advanced power units and their equipment such as boilers, turbines, auxiliaries, process and environmental control systems similar to those produced by the world’s leading manufacturers. Their performance and ways of implementation are discussed.« less
Environmental review of the Panda-Brandywine cogeneration project. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walters, G.; Keating, R.; Huggins, A.
1997-02-01
The Maryland Public Service Commission (PSC) granted a Certificate of Public Convenience and Necessity (CPCN) to Panda-Brandywine, L.P., to construct and operate a 248-megawatt (electric) generating station near Brandywine, Prince George`s County, Maryland. This report describes PPRP`s evaluation of the environmental and socioeconomic impacts of the Panda-Brandywine facility, summarizes the results of that evaluation, and presents recommendations for license conditions which have been incorporated into Panda`s CPCN. The document includes description of the proposed facility, host facility, and associated linear facilities (transmission line, pipelines); discussion of existing environmental and socioeconomic conditions at the site and in the vicinity; analysis ofmore » the potential air quality, surface water, biological, ground water, socioeconomic, cultural, and noise impacts from the proposed facility; and discussion of critical engineering issues associated with operation of the facility, including water supply, water discharge, and fuel handling.« less
Modeling Methodologies for Design and Control of Solid Oxide Fuel Cell APUs
NASA Astrophysics Data System (ADS)
Pianese, C.; Sorrentino, M.
2009-08-01
Among the existing fuel cell technologies, Solid Oxide Fuel Cells (SOFC) are particularly suitable for both stationary and mobile applications, due to their high energy conversion efficiencies, modularity, high fuel flexibility, low emissions and noise. Moreover, the high working temperatures enable their use for efficient cogeneration applications. SOFCs are entering in a pre-industrial era and a strong interest for designing tools has growth in the last years. Optimal system configuration, components sizing, control and diagnostic system design require computational tools that meet the conflicting needs of accuracy, affordable computational time, limited experimental efforts and flexibility. The paper gives an overview on control-oriented modeling of SOFC at both single cell and stack level. Such an approach provides useful simulation tools for designing and controlling SOFC-APUs destined to a wide application area, ranging from automotive to marine and airplane APUs.
Fuel change possibilities in small heat source
NASA Astrophysics Data System (ADS)
Durčanský, Peter; Kapjor, Andrej; Jandačka, Jozef
2017-09-01
Rural areas are characterized by a larger number of older family houses with higher fuel consumption for heating. Some areas are not gasified, which means that the fuel base for heating the buildings is very limited. Heating is mainly covered by solid fuels with high emissions and low efficiency. But at the same time, the amount of energy in the form of biowaste can be evaluated and used further. We will explore the possibilities to convert biogas to heat of using a gas burner in a small heat source. However, the heat produced can be used other than for heating or hot water production. The added value for heat generation can be the production of electricity, in the use of heat energy through cogeneration unit with unconventional heat engine. The proposed solution could economically benefit the entire system, because electricity is a noble form of energy and its use is versatile.
Wind and solar powered turbine
NASA Technical Reports Server (NTRS)
Wells, I. D.; Koh, J. L.; Holmes, M. (Inventor)
1984-01-01
A power generating station having a generator driven by solar heat assisted ambient wind is described. A first plurality of radially extendng air passages direct ambient wind to a radial flow wind turbine disposed in a centrally located opening in a substantially disc-shaped structure. A solar radiation collecting surface having black bodies is disposed above the fist plurality of air passages and in communication with a second plurality of radial air passages. A cover plate enclosing the second plurality of radial air passages is transparent so as to permit solar radiation to effectively reach the black bodies. The second plurality of air passages direct ambient wind and thermal updrafts generated by the black bodies to an axial flow turbine. The rotating shaft of the turbines drive the generator. The solar and wind drien power generating system operates in electrical cogeneration mode with a fuel powered prime mover.
H.sub.2 /C.sub.12 fuel cells for power and HCl production - chemical cogeneration
Gelb, Alan H.
1991-01-01
A fuel cell for the electrolytic production of hydrogen chloride and the generation of electric energy from hydrogen and chlorine gas is disclosed. In typical application, the fuel cell operates from the hydrogen and chlorine gas generated by a chlorine electrolysis generator. The hydrogen chloride output is used to maintain acidity in the anode compartment of the electrolysis cells, and the electric energy provided from the fuel cell is used to power a portion of the electrolysis cells in the chlorine generator or for other chlorine generator electric demands. The fuel cell itself is typically formed by a passage for the flow of hydrogen chloride or hydrogen chloride and sodium chloride electrolyte between anode and cathode gas diffusion electrodes, the HCl increa This invention was made with Government support under Contract No. DE-AC02-86ER80366 with the Department of Energy and the United States Government has certain rights thereto.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shafrir, Shai N.; Romanofsky, Henry J.; Skarlinski, Michael
2009-12-10
We report on magnetorheological finishing (MRF) spotting experiments performed on glasses and ceramics using a zirconia-coated carbonyl-iron (CI)-particle-based magnetorheological (MR) fluid. The zirconia-coated magnetic CI particles were prepared via sol-gel synthesis in kilogram quantities. The coating layer was {approx}50-100 nm thick, faceted in surface structure, and well adhered. Coated particles showed long-term stability against aqueous corrosion. ''Free'' nanocrystalline zirconia polishing abrasives were cogenerated in the coating process, resulting in an abrasive-charged powder for MRF. A viable MR fluid was prepared simply by adding water. Spot polishing tests were performed on a variety of optical glasses and ceramics over a periodmore » of nearly three weeks with no signs of MR fluid degradation or corrosion. Stable material removal rates and smooth surfaces inside spots were obtained.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-08-01
This report presents the results of a brief study of industral, mining, and agricultural sector energy demands in Peru. The study establishes current energy demands and sectoral activities, and projects future energy needs through the year 2000. With respect to energy demands, the subsectors covered are: mining and non-ferrous metals, iron and steel, cement, oil refining, petrochemicals, fertilizers, and agriculture (major crops). Total energy demands for these subsectors are developed for 1976, 1985, and 2000, assuming full-capacity operation for the majority of the plants. Potential options developed for reducing energy use in these sectors are: increased coal use, improved energymore » efficiency in the manufacturing sector, use of agricultural wastes as fuel, possible displacement of oil by hydroelectricity, use of geothermal energy, increased use of water materials for the cement and construction industries, and possible promotion of cogeneration systems (electricity/steam). (MCW)« less
Thailand's downstream projects proliferate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-06-03
Thailand continues to press expansion and modernization of its downstream sector. Among recent developments: Construction of an olefins unit at Thailand's second major petrochemical complex and a worldscale aromatics unit in Thailand is threatened by rising costs. Thailand's National Petrochemical Corp (NPC) let a 9 billion yen contract to Mitsui Engineering and Shipbuilding Co. and C. Itoh and Co. for a dual fuel cogeneration power plant at its Mab Ta Phud, Rayong province, petrochemical complex. Financing is in place to flash a green light for a $530 million Belgian-Thai joint venture sponsoring a worldscale polyvinyl chloride/vinyl chloride monomer plant inmore » Thailand. Work is more than 50% complete on the $345 million second phase expansion of Thai Oil's Sri Racha refinery in Chon Buri province. Petroleum Authority of Thailand (PTT) endorsed a plan to install two more natural gas processing plants in Thailand to meet rapidly growing domestic demand for petroleum gas.« less
Analysis of PURPA and solar energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, M.
The Public Utility Regulatory Policies Act of 1978 (PURPA) is designed to promote energy conservation, the efficient use of utility resources, and equitable rates. PURPA specifically directs the Federal Energy Regulatory Commission (FERC) to encourage small power production from renewable resources (and also cogeneration of electric energy as well as heat) by setting standards under which facilities qualify for interconnection, and guidelines for sales between utilities and independent facilities. The way FERC carries out this mandate may critically affect the development of solar alternatives to electric power production from fossil and nuclear resources. This report comments on proposed FERC regulationsmore » and suggests ways to encourage small power production within the PURPA mandate. In addition, some internal strains within PURPA are analyzed that seem to limit the effectiveness with which FERC can encourage independent facilities, and possible modifications to PURPA are suggested. 255 references.« less
Renewable power sparks financial interest
NASA Astrophysics Data System (ADS)
Norman, C.
1981-06-01
A legal and economic assessment is given of section 210 of the Public Utility Regulatory Practices Act (PURPA) of 1978, which guarantees a market for small electrical power producers by requiring utilities to buy from them at premium rates and, in addition, exempts them from regulatory restrictions imposed on utilities. To qualify, small power producers are limited to a capacity of 80 MW at any one site, and they must use such renewable energy sources as wind, hydroelectric, biomass, solar, and waste products. There is no size limit for industrial cogeneration facilities, but those that burn oil or natural gas must meet efficiency standards to qualify. Section 210 has, however, been seriously challenged in the courts by utility companies viewing it as a Federal infringement of the right of States to regulate their utilities; a court ruling favorable to the utilities has already been given in Mississippi, and similar rulings are being sought in New York.
Phosphoric acid fuel cell 1.3 MW plant in Milan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colombo, M.; Vigano, A.
1997-07-01
At the end of the 80`s Aem, ENEA and Ansaldo Ricerche began to design and build a 1.3 MW phosphoric-acid-fuel-cell power plant for the production of electrical power and heat; this plant was built and installed in the Bicocca site, in the north-east area of Milan, where a great development is being promoted. Aem has been taking over the plant since July 1995. Its aim is to test the extensively advantages of this technology for both conversion efficiency and low environmental impact. The experimentation will have to recognize the key elements in order to plan and create the multi-megawatt plantsmore » with the phosphoric acid technology, opening the experimentation to international partners, like users, industries and Universities interested in the development and the application of these new systems of energy cogeneration.« less
NASA Astrophysics Data System (ADS)
Hill, R. F.
The characterization, development, and availability of various energy sources for large scale energy production are discussed. Attention is given to government, industry, and international policies on energy resource development and implementation. Techniques for energy analysis, planning, and regulation are examined, with consideration given to conservation practices, military energy programs, and financing schemes. Efficient energy use is examined, including energy and load management, building retrofits, and cogeneration installations, as well as waste heat recovery. The state of the art of nuclear, fossil, and geothermal power extraction is investigated, with note taken of synthetic fuels, fluidized bed combustion, and pollution control in coal-powered plants. Finally, progress in renewable energy technologies, including solar heating and cooling, biomass, and large and small wind energy conversion devices is described. No individual items are abstracted in this volume