ERIC Educational Resources Information Center
Lathrop, Janice
Task analyses are provided for two duty areas for the occupation of physical therapist assistant in the rehabilitation services cluster. Ten tasks are listed for the duty area "providing therapeutic measures": apply cold compress, administer hot soak, apply heat lamp, apply warm compress, apply ice bag, assist with dressing change, apply…
Dabiri, Ganary; Hammerman, Scott; Falanga, Vincent
2014-01-01
Venous leg ulcers affect millions of patients worldwide and are a tremendous financial burden on our healthcare system. The hallmark of venous disease of the lower extremities is venous hypertension, and compression is the current mainstay of treatment. However, many patients are noncompliant, in part because of the complexity of the dressings and the difficulties with application and removal. The aim of our study was to determine an effective compression dressing regimen for patients with venous leg ulcers who require changing the ulcer primary dressing twice daily. We used two layers of a latex free tubular elastic bandage for compression. The primary endpoint of our study was increased wound healing rate and our secondary endpoint was complete wound closure. All active study subjects had positive healing rates at week 4 and week 8. Two subjects achieved complete wound closure by week 8. We conclude that compression with a latex-free tubular elastic bandage can be safely used in patients with venous leg ulcers requiring frequent dressing changes. This type of compression allows for daily inspection of wounds, dressing changes at home, flexibility in the context of clinical trials, and is a compromise for patients that are intolerant to compression dressings. PMID:24267477
2014-04-01
The MSD is comprised of a syringe applicator filled with compressed chitosan coated sponges which are delivered into the wound at the site of the...transmitted effectively to the deep subclavian vessels to stop hemorrhage. As a result of their non-compressible nature and paucity of effective field...followed by three minutes of compression to the packed dressing. The mini- sponge dressing (MSD) is a novel product that utilizes compressed, chitosan
Vas, Jorge; Modesto, Manuela; Mendez, Camila; Perea-Milla, Emilio; Aguilar, Inmaculada; Carrasco-Lozano, Jesus Manuel; Faus, Vicente; Martos, Francisco
2008-01-01
Background Venous leg ulcers constitute a chronic recurring complaint that affects 1.0–1.3% of the adult population at some time in life, and which corresponds to approximately 75% of all chronic ulcers of the leg. Multilayer compression bandaging is, at present, the only treatment that has been proved to be effective in treating this type of ulcer. There is no consensus, however, about the dressings that may be applied, beneath the compression, to promote the healing of this type of ulcer, as there does not seem to be any added benefit from using special dressings rather than simple, low-adherence ones. As well as analgesia, acupuncture provokes peripheral vasodilation, in skin and muscles – which has been demonstrated both experimentally and in clinical practice – probably due to the axon reflex, among other mechanisms. The aim of the present study is to measure the effectiveness and cost of compression treatment for venous leg ulcers combined with special dressings, in comparison with low-adherence ones and acupuncture. Methods/design Cluster-randomized open-labeled trial, at 15 primary healthcare clinics in the Sevilla-Sur Healthcare District, with a control group treated with compression bandaging and low-adherence dressings; the experiment will consist, on the one hand, of the compression treatment applied in combination with special dressings (Treatment 1), and on the other, the compression treatment applied in association with low-adherence dressings, together with acupuncture (Treatment 2). Discussion The results will be measured and recorded in terms of the median time elapsed until complete healing of the ulcer, and the rate of complete healing at 3 months after beginning the treatment. An economic analysis will also be made. This study, carried out in the context of real clinical practice, will provide information for decision-taking concerning the effectiveness of special dressings. Moreover, for the first time a high-quality study will evaluate the effectiveness of acupuncture in the process of healing venous leg ulcers. Trial registration Current Controlled Trials ISRCTN26438275. PMID:18547419
Control of traumatic wound bleeding by compression with a compact elastic adhesive dressing.
Naimer, Sody Abby; Tanami, Menachem; Malichi, Avishai; Moryosef, David
2006-07-01
Compression dressing has been assumed effective, but never formally examined in the field. A prospective interventional trial examined efficacy and feasibility of an elastic adhesive dressing compression device in the arena of the traumatic incident. The primary variable examined was the bleeding rate from wounds compared before and after dressing. Sixty-two consecutive bleeding wounds resulting from penetrating trauma were treated. Bleeding intensity was profuse in 58%, moderate 23%, and mild in 19%. Full control of bleeding was achieved in 87%, a significantly diminished rate in 11%, and, in 1 case, the technique had no influence on the bleeding rate. The Wilcoxon test for variables comparing bleeding rates before and after the procedure obtained significant difference (Z = -6.9, p < 0.01). No significant complications were observed. Caregivers were highly satisfied in 90% of cases. Elastic adhesive dressing was observed as an effective and reliable technique, demonstrating a high rate of success without complications.
NASA Astrophysics Data System (ADS)
Li, Yan-Ming; Liang, Zhen-Zhen; Song, Chun-Lei
2016-05-01
To compare the effect of 3 kinds of different materials on the hemostasis of puncture site after central venous catheterization. Method: A selection of 120 patients with peripheral central venous catheter chemotherapy in the Affiliated Hospital of our university from January 2014 to April 2015, Randomly divided into 3 groups, using the same specification (3.5cm × 2cm) alginate gelatin sponge and gauze dressing, 3 kinds of material compression puncture point, 3 groups of patients after puncture 24 h within the puncture point of local blood and the catheter after the catheter 72 h within the catheter maintenance costs. Result: (1) The local infiltration of the puncture point in the 24 h tube: The use of alginate dressing and gelatin sponge hemostatic effect is better than that of compression gauze. The difference was statistically significant (P <0.05). Compared with gelatin sponge and alginate dressing hemostatic effect, The difference was not statistically significant. (2) Tube maintenance cost: Puncture point using gelatin sponge, The local maintenance costs of the catheter within 72 h after insertion of the tube are lowest, compared with alginate dressing and gauze was significant (P<0.05). Conclusion: The choice of compression hemostasis material for the puncture site after PICC implantation, using gelatin sponge and gauze dressing is more effective and economic.
... sure cold foods are kept cold and hot foods are kept hot. Use only salad dressings, sauces, and salsas that come in single-serving packages. TIPS FOR TRAVELING WHERE CONTAMINATION IS COMMON: DO NOT eat raw vegetables or ...
Mehmood, Nasir; Hariz, Alex; Templeton, Sue; Voelcker, Nicolas H
2014-11-18
This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data are then transmitted wirelessly to a receiver connected to a mobile device. An error-correction algorithm is developed to compensate the degradation in measurement quality due to battery power drop over time. An Android application is also implemented to automatically receive, process, and display the sensed wound parameters. The performance of the sensing system is first validated on a mannequin limb using a compression bandage and wound dressings, and then tested on a healthy volunteer to acquire real-time performance parameters. The results obtained here suggest that this dual mode sensor can perform reliably when placed on a human limb.
Mehmood, Nasir; Hariz, Alex; Templeton, Sue; Voelcker, Nicolas H.
2014-01-01
This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data are then transmitted wirelessly to a receiver connected to a mobile device. An error-correction algorithm is developed to compensate the degradation in measurement quality due to battery power drop over time. An Android application is also implemented to automatically receive, process, and display the sensed wound parameters. The performance of the sensing system is first validated on a mannequin limb using a compression bandage and wound dressings, and then tested on a healthy volunteer to acquire real-time performance parameters. The results obtained here suggest that this dual mode sensor can perform reliably when placed on a human limb. PMID:25412216
Bohn, Gregory A; Gass, Kimberly
2014-10-01
The purpose of this study was to describe the rate of closure observed in venous leg ulcers during treatment with ovine collagen extracellular matrix dressings and compression. Fourteen patients with 23 wounds were retrospectively evaluated with respect to healing rates, time to closure, and weekly facility charge fees.
Kanda, K; Tsuchiya, J; Seto, M; Ohnaka, T; Tochihara, Y
1995-06-01
Thermal conditions in the bathroom and physiological responses were examined during winter and summer. The subjects were 22 male and 20 female elderly people, between 65 and 88 years old living in 25 houses in Gunma Prefecture, Japan. Heart rate, blood pressure, skin temperature and thermal sensation were measured during bathing. Changes in thermal sensation due to bathing were assessed in the living room and dressing room on a 9-point scale. Then they were asked about the purposes of bathing and the facilities of bathroom and dressing room. The results are summarized as follows: 1. The purpose of bathing in winter was to warm up for more than 80% of the subjects. In summer, all subjects felt refreshed by bathing. Eighty-five percent of the subjects took a bath every other day in both seasons. 2. Fifty-two percent of the bathrooms had no ventilating fans and 32% had no exclusive dressing rooms. 3. The average room temperature in the dressing rooms was 13-14 degrees C in winter. Thermal sensation was 'cool', 'slightly cold' or 'cold' for more than two-thirds of the subjects when they were partially nude, and there were no heaters in most dressing rooms. 4. The heart rate increased steadily, and reached a maximum value in a partially dressed condition in both seasons. 5. In winter, a marked increase of systolic blood pressure was observed in the partially nude condition. There was a significant difference between the before bathing condition and partially nude condition in winter.(ABSTRACT TRUNCATED AT 250 WORDS)
Thermal Face Protection Delays Finger Cooling and Improves Thermal Comfort during Cold Air Exposure
2011-01-01
code) 2011 Journal Article-Eur Journal of Applied Physiology Thermal face protection delays Fnger cooling and improves thermal comfort during cold air...remains exposed. Facial cooling can decrease finger blood flow, reducing finger temperature (Tf). This study examined whether thermal face protection...limits Wnger cooling and thereby improves thermal comfort and manual dexterity during prolonged cold exposure. Tf was measured in ten volunteers dressed
Ozcan, Mustafa; Yalcintan, Hulya; Tölü, Cemil; Ekiz, Bulent; Yilmaz, Alper; Savaş, Türker
2014-01-01
The aim was to compare the carcass and meat quality characteristics of male and female Gokceada Goat kids produced in extensive (n=20) and semi-intensive (n=20) systems. In extensive and semi-intensive produced kids pre-slaughter weights were 17.44 and 12.51 kg; cold carcass weights were 8.66 and 5.35 kg and cold dressing percentages were 54.9 and 49.28%, respectively. The effect of kid sex was not significant on hot and cold dressing percentages, back fat thickness, M. longissimus dorsi section area, carcass fatness and conformation scores, and carcass measurements, while female kids had higher omental and mesenteric fat and kidney knob and channel fat percentages than male kids. Extensive produced kids had lower meat lightness. Panellists evaluated extensive system kids with higher scores of kid odour intensity, flavour intensity and overall acceptability. It was concluded that it would be more appropriate to use an extensive system in Gokceada Goat breeding for kid meat production. © 2013.
NASA Astrophysics Data System (ADS)
Barba, Bin Jeremiah D.; Aranilla, Charito T.; Relleve, Lorna S.; Cruz, Veriza Rita C.; Vista, Jeanina Richelle; Abad, Lucille V.
2018-03-01
Uncontrolled hemorrhage remains a persistent problem especially in anatomical areas where compression and tourniquet cannot be applied. Hemostatic agents are materials which can achieve control of bleeding in acute, life-threatening traumatic coagulopathy. In this study, we prepared biocompatible hydrogel-based hemostat crosslinked by ionizing radiation. Granules made from carboxymethyl cellulose and dressing from kappa carrageenan and polyethylene oxide were characterized by FT-IR, SEM, and gel analysis. Gamma radiation with a dose of 25 kGy was used for sterilization process. Stability studies indicate that the products remain effective with a shelf life of up to 18 months based on accelerated aging. Both hemostatic agents were demonstrated to be effective in vitro blood clotting assays showing a low blood clotting index, high platelet adhesion capacity and accelerated clotting time. Hemostat granules and dressing were also used in a femoral artery rat bleeding model where hemorrhage control was achieved in 90 s without compression and resulted in 100% survival rate after a 7 and 14-day observation.
A medical bandage in an Italian Renaissance mummy (Naples, XVI century).
Giuffra, Valentina; Marinozzi, Silvia; Vultaggio, Claudia; Fornaciari, Gino
2008-01-01
A dressing was observed on the left arm of the mummy of Mary of Aragon (1503-1568), under her precious Renaissance clothes. It consisted of a true medical bandage, covering a large syphilitic cutaneous ulcer, with a sulphur-embedded wad still in situ. The bandage has a very peculiar shape, rather different from the usual dressings described in the contemporary medical texts: a central rectangular pad, used as compressing appliance, is provided with a sort of pocket containing ivy leaves. The function of the dressing was not only to cover and protect the ulcer, but also to apply a plant drug. This is the first case of ancient medical bandage studied directly on a mummified body.
A comparison of an antibacterial sandwich dressing vs dressing containing silver.
Krasowski, Grzegorz; Jawień, Arkadiusz; Tukiendorf, Andrzej; Rybak, Zbigniew; Junka, Adam; Olejniczak-Nowakowska, Małgorzata; Bartoszewicz, Marzenna; Smutnicka, Danuta
2015-01-01
The purpose of this study was to compare the efficacy of dressings containing octenidine vs. dressings containing silver in the wound healing in the course of a chronic venous disease. There were two groups of 40 patients who met the inclusion criteria and who did not meet the exclusion criteria. The patients were randomly assigned into the groups (envelope method). The first, "O group" was treated with octenidine-based dressings. The second, "S group" was treated with silver dressings. The study lasted for 56 days. All patients in the research were treated with medical compression stockings with cotton understockings. Microbiological eradication was observed on the 28th day of the study among 33% of patients in the treatment group vs. 6% in control group. On the 56th day of the treatment, these percentages equalled 72% and 35%. The rate of healing was faster in the 0 group than in the S group. In the wounds <10 cm(2) it was faster by 1.35 cm(2)/week and in wounds >10 cm(2) it equalled 3.44 cm(2). The reduction of pain level was 37.5% higher in the O group, in contrast with the S group. One change of a dressing in the O group led to a 0.06 cm(2) greater wound size reduction and in the case of wounds >10 cm(2) to 0.29 cm(2) reduction compared with the S group. The presented results indicate that the efficacy of dressings containing octenidine is higher compared to silver dressings. © 2015 by the Wound Healing Society.
A primer on clothing systems for cold-weather field work
Denner, Jon
1990-01-01
Conducting field work in cold weather is a demanding task. The most important safety consideration for field personnel is to maintain normal body temperature and avoid hypothermia.The human body adjusts to cold temperatures through different physiological processes. Heat production is enhanced by increases in the rates of basal metabolism, specific dynamic action, and physical exercise, and heat loss is reduced by vasoconstriction.Physiological adaptations alone are inadequate to stop rapid heat loss in cold temperatures. Additional insulation in the form of cold-weather clothing is necessary to retain heat.The most practical method of dressing for winter conditions is the layering system. Wearing multiple thin layers allows one to fine tune the insulation needed for different temperatures and activity levels.
A prospective randomized clinical trial to evaluate methods of postoperative care of hypospadias.
McLorie, G; Joyner, B; Herz, D; McCallum, J; Bagli, D; Merguerian, P; Khoury, A
2001-05-01
Hypospadias repair is a common operation performed by pediatric urologists. Perhaps the greatest variable and source of controversy of postoperative care is the surgical dressing. We hypothesized that using no dressing would achieve surgically comparable results to those traditionally achieved by a postoperative dressing and it would also simplify postoperative parent delivered home care. Accordingly we designed a prospective randomized clinical trial to compare surgical outcome and postoperative care after hypospadias repair in boys with no dressing and those who received 1 of the 2 most common types of dressing. In a 12-month period 120 boys with an average age of 2.2 years underwent primary 1-stage hypospadias repair at a single center with 4 participating surgeons. Repair was performed in 60 boys with proximal and 60 with distal hypospadias on an outpatient basis. Ethics and Internal Review Board approval, and informed consent were obtained. Boys were then prospectively randomized to receive no dressing, an adhesive biomembrane dressing or a compressive wrap dressing. Comprehensive instructions on postoperative care were distributed to all families and a questionnaire was distributed to the parents at the initial followup. Surgical outcome was evaluated and questionnaire responses were analyzed. Fisher's exact test was done to test the significance of differences in surgical outcomes and questionnaire responses. A total of 117 boys completed the prospective randomized trial. Surgical staff withdrew 3 cases from randomized selection to place a dressing for postoperative hemostasis. We obtained 101 questionnaires for response analysis. The type or absence of the dressing did not correlate with the need for repeat procedures, urethrocutaneous fistula, or meatal stenosis or regression. Analysis revealed less narcotic use in the no dressing group and fewer telephone calls to the urology nurse, or on-call resident and/or fellow. These findings were statistically significant. In addition, there were more unscheduled visits to the urology clinic, emergency room or primary physician office by boys with than without a dressing. Furthermore, 29% of the parents were not psychologically prepared to remove the dressing and 12% were so reluctant that the dressing was removed at the urology outpatient clinic. The surgical outcome and rate of adverse events or complications were not compromised without a postoperative dressing. An absent dressing simplified postoperative ambulatory parent delivered home care. We recommend that dressings should be omitted from routine use after hypospadias repair.
Modelling the cost-effectiveness of electric stimulation therapy in non-healing venous leg ulcers.
Taylor, R R; Sladkevicius, E; Guest, J F
2011-10-01
To estimate the cost-effectiveness of using electric stimulation (ES) therapy (Accel-Heal) plus dressings and compression bandaging compared with dressings and compression bandaging alone in treating chronic, non-healing venous leg ulcers (VLUs) of >6 months' duration from the perspective of the National Health Service (NHS) in the UK. A 5-month Markov model was constructed, depicting the management of a chronic, non-healing VLU of >6 months' duration. The model considers the decision by a clinician to continue with a patient's previous care plan (comprising dressings and compression bandaging) or treating with ES therapy plus dressings and compression bandaging. The model was used to estimate the relative cost-effectiveness of ES therapy at 2008-2009 prices. According to the model, 38% of VLUs are expected to heal within 5 months after starting ES therapy, with a further 57% expected to improve. This improvement in clinical outcome is expected to lead to a 6% health gain of 0.017 QALYs (from 0.299 to 0.316 QALYs) over 5 months. The model also showed that using ES therapy instead of continuing with a patient's previous care plan is expected to reduce the NHS cost of managing them by 15%, from £880 to £749, due in part to a 27% reduction in the requirement for nurse visits (from mean 49.0 to 35.9 visits per patient) over the first 5 months after the start of treatment. Hence, use of ES therapy was found to be a dominant treatment (improved outcome for less cost). Within the model's limitations, use of ES therapy potentially affords the NHS a cost-effective treatment, compared with patients remaining on their previous care plan in managing chronic, non-healing VLUs of >6 months' duration. However, this is dependant on the number of ES therapy units per treatment, the unit cost of the device, and the number of nurse visits required to manage patients in clinical practice. This study was sponsored by Synapse Microcurrent Ltd., manufacturers of Accel-Heal. The authors have no other conflicts of interest that are directly relevant to the content of this manuscript. In particular, Synapse Microcurrent Ltd. had no role in the study design, in the collection, analysis and interpretation of data, or in writing the manuscript.
Khosravan, Shahla; Mohammadzadeh-Moghadam, Hossein; Mohammadzadeh, Fatemeh; Fadafen, Samane Ajam Khames; Gholami, Malihe
2017-01-01
Breast engorgement affects lactation. The present study was conducted to determine the effect of hollyhock combined with warm and cold compresses on improving breast engorgement in lactating women. Participants included 40 women with breast engorgement divided into intervention and control groups, with participants in both groups being applied routine interventions and warm compress before nursing and a cold compress after nursing; however, the intervention group was also applied hollyhock compress. Both groups received these treatments 6 times during 2 days. The data collected were analyzed in SPSS-16 using a generalized estimating equation. According to the results, a significant difference was observed in the overall breast engorgement severity in the intervention group (P < .001). The severity of breast engorgement was also found to have a significant relationship with time (P < .001). According to the findings, hollyhock leaf compress combined with performing routine interventions for breast engorgement can improve breast engorgement. © The Author(s) 2015.
Comparison of 10 Hemostatic Dressings in a Groin Puncture Model in Swine
2009-09-01
attended or remote surgical theaters as well as for first aid bandaging in extreme sport.Methods to suppress massive external hemorrhage should be provided...Products Newport, O Instaclot (IC) Emergency Medical Devices Loxa WoundStat (WS) TraumaCure, Inc. Bethesda, Md Solid (flexible) agents Alpha Bandage ...referred to throughout are listed in Table I. The hemostatic products and the standard compressed gauze bandage (SD; H&H compressed gauze, H&H
Cardiac pacemaker dysfunction in children after thoracic drainage catheter manipulation.
Lobdell, K W; Walters, H L; Hudson, C; Hakimi, M
1997-05-01
Two children underwent placement of permanent, epicardial-lead, dual-chamber, unipolar pacemaker systems for complete heart block. Postoperatively, both patients demonstrated subcutaneous emphysema-in the area of their pulse generators-temporally related to thoracic catheter manipulation. Acutely, each situation was managed with manual compression of the pulse generator, ascertaining appropriate pacemaker sensing and pacing. Maintenance of compression with pressure dressings, vigilant observation/monitoring, and education of the care givers resulted in satisfactory pacemaker function without invasive intervention.
NASA Astrophysics Data System (ADS)
Arifin Shariffudin, Kamarul; Karuppanan, Saravanan; Patil, Santosh S.
2017-10-01
Cold expansion of fastener/rivet holes is a common way to generate beneficial compressive residual stress around the fastener hole. In this study, cold expansion process was simulated by finite-element method in order to determine the residual stress field around two cold expanded holes by varying the plate thickness and expansion ratio of the hole. The model was developed in ANSYS and assigned to aluminium alloy 7475-T61 material model. The results showed that the residual stress become more compressive as the plate thickness is increased up to t/d = 2.6 and decreased for further level of thickness. In addition, the residual stress at the edge of the hole become more compressive as the expansion ratio is increased up to 4.5% and decreased for further level of expansion. This study also found that the residual stresses near the entrance and the exit face of the plate are less compressive than the residual stresses on the mid-thickness of the plate.
Alcohol cold starting - A theoretical study
NASA Technical Reports Server (NTRS)
Browning, L. H.
1983-01-01
Two theoretical computer models have been developed to study cold starting problems with alcohol fuels. The first model, a droplet fall-out and sling-out model, shows that droplets must be smaller than 50 microns to enter the cylinder under cranking conditions without being slung-out in the intake manifold. The second model, which examines the fate of droplets during the compression process, shows that the heat of compression can be used to vaporize small droplets (less than 50 microns) producing flammable mixtures below freezing ambient temperatures. While droplet size has the greater effect on startability, a very high compression ratio can also aid cold starting.
First-principles molecular dynamics simulations of anorthite (CaAl2Si2O8) glass at high pressure
NASA Astrophysics Data System (ADS)
Ghosh, Dipta B.; Karki, Bijaya B.
2018-06-01
We report first-principles molecular dynamics study of the equation of state, structural, and elastic properties of CaAl2Si2O8 glass at 300 K as a function of pressure up to 155 GPa. Our results for the ambient pressure glass show that: (1) as with other silicates, Si atoms remain mostly (> 95%) under tetrahedral oxygen surroundings; (2) unlike anorthite crystal, presence of high-coordination (> 4) Al atoms with 30% abundance; (3) and significant presence of both non-bridging (8%) and triply (17%) coordinated oxygen. To achieve the glass configurations at various pressures, we use two different simulation schedules: cold and hot compression. Cold compression refers to sequential compression at 300 K. Compression at 3000 K and subsequent isochoric quenching to 300 K is considered as hot compression. At the initial stages of compression (0-10 GPa), smooth increase in bond distance and coordination occurs in the hot-compressed glass. Whereas in cold compression, Si (also Al to some extent) displays mainly topological changes (without significantly affecting the average bond distance or coordination) in this pressure interval. Further increase in pressure results in gradual increases in mean coordination, with Si-O (Al-O) coordination eventually reaching and remaining 6 (6.5) at the highest compression. Similarly, the ambient pressure Ca-O coordination of 5.9 increases to 9.5 at 155 GPa. The continuous pressure-induced increase in the proportion of oxygen triclusters along with the appearance and increasing abundance of tetrahedral oxygens results in mean O-T (T = Si and Al) coordination of > 3 from a value of 2.1 at ambient pressure. Due to the absence of kinetic barrier, the hot-compressed glasses consistently produce greater densities and higher coordination numbers than the cold compression cases. Decompressed glasses show irreversible compaction along with retention of high-coordination species when decompressed from pressure ≥ 10 GPa. The different density retention amounts (12, 17, and 20% when decompressed from 12, 40, and 155 GPa, respectively) signifies that the degree of irreversibility depends on the peak pressure of decompression. The calculated compressional and shear wave velocities (5 and 3 km/s at 0 GPa) for the cold-compressed case display sluggish pressure response in the 0-10 GPa interval as opposed to smooth increase in the hot-compressed one. Shear velocity saturates rather rapidly with a value of 5 km/s, whereas compressional wave velocity displays continuous increase, reaching/exceeding 12.5 km/s at 155 GPa. These structural details suggest that the pressure response of the cold-compressed glasses is not only inherently different at the 0-10 GPa interval, the density, coordination, and wave velocity data are consistently lower than the hot-compressed glasses. Hot-compressed glasses may, therefore, be the better analog in the study of high-pressure silicate melts.
Structure and Properties of Silica Glass Densified in Cold Compression and Hot Compression
NASA Astrophysics Data System (ADS)
Guerette, Michael; Ackerson, Michael R.; Thomas, Jay; Yuan, Fenglin; Bruce Watson, E.; Walker, David; Huang, Liping
2015-10-01
Silica glass has been shown in numerous studies to possess significant capacity for permanent densification under pressure at different temperatures to form high density amorphous (HDA) silica. However, it is unknown to what extent the processes leading to irreversible densification of silica glass in cold-compression at room temperature and in hot-compression (e.g., near glass transition temperature) are common in nature. In this work, a hot-compression technique was used to quench silica glass from high temperature (1100 °C) and high pressure (up to 8 GPa) conditions, which leads to density increase of ~25% and Young’s modulus increase of ~71% relative to that of pristine silica glass at ambient conditions. Our experiments and molecular dynamics (MD) simulations provide solid evidences that the intermediate-range order of the hot-compressed HDA silica is distinct from that of the counterpart cold-compressed at room temperature. This explains the much higher thermal and mechanical stability of the former than the latter upon heating and compression as revealed in our in-situ Brillouin light scattering (BLS) experiments. Our studies demonstrate the limitation of the resulting density as a structural indicator of polyamorphism, and point out the importance of temperature during compression in order to fundamentally understand HDA silica.
Effect of cold compress application on tissue temperature in healthy dogs.
Millard, Ralph P; Towle-Millard, Heather A; Rankin, David C; Roush, James K
2013-03-01
To measure the effect of cold compress application on tissue temperature in healthy dogs. 10 healthy mixed-breed dogs. Dogs were sedated with hydromorphone (0.1 mg/kg, IV) and diazepam (0.25 mg/kg, IV). Three 24-gauge thermocouple needles were inserted to a depth of 0.5 (superficial), 1.0 (middle), and 1.5 (deep) cm into a shaved, lumbar, epaxial region to measure tissue temperature. Cold (-16.8°C) compresses were applied with gravity dependence for periods of 5, 10, and 20 minutes. Tissue temperature was recorded before compress application and at intervals for up to 80 minutes after application. Control data were collected while dogs received identical sedation but with no cold compress. Mean temperature associated with 5 minutes of application at the superficial depth was significantly decreased, compared with control temperatures. Application for 10 and 20 minutes significantly reduced the temperature at all depths, compared with controls and 5 minutes of application. Twenty minutes of application significantly decreased temperature at only the middle depth, compared with 10 minutes of application. With this method of cold treatment, increasing application time from 10 to 20 minutes caused a further significant temperature change at only the middle tissue depth; however, for maximal cooling, the minimum time of application should be 20 minutes. Possible changes in tissue temperature and adverse effects of application > 20 minutes require further evaluation.
Permanently densified SiO2 glasses: a structural approach.
Martinet, C; Kassir-Bodon, A; Deschamps, T; Cornet, A; Le Floch, S; Martinez, V; Champagnon, B
2015-08-19
Densified silica can be obtained by different pressure and temperature paths and for different stress conditions, hydrostatic or including shear. The density is usually the macroscopic parameter used to characterize the different compressed silica samples. The aim of our present study is to compare structural modifications for silica glass, densified from several routes. For this, densified silica glasses are prepared from cold and high temperature (up to 1020 °C) compressions. The different densified glasses obtained in our study are characterized by micro-Raman spectroscopy. Intertetrahedral angles from the main band relative to the bending mode decrease and their values are larger for densified samples from high temperature compression than those samples from cold compression. The relative amount of 3-membered rings deduced from the D2 line area increases as a function of density for cold compression. The temperature increase during the compression process induces a decrease of the 3 fold ring population. Moreover, 3 fold rings are more deformed and stressed for densified samples at room temperature at the expense of those densified at high temperature. Temperature plays a main role in the reorganization structure during the densification and leads to obtaining a more relaxed structure with lower stresses than glasses densified from cold compression. The role of hydrostatic or non-hydrostatic applied stresses on the glass structure is discussed. From the Sen and Thorpe central force model, intertetrahedral angle average value and their distribution are estimated.
Recrystallization characteristics and interfacial oxides on the compression bonding interface
NASA Astrophysics Data System (ADS)
Xie, Bijun; Sun, Mingyue; Xu, Bin; Li, Dianzhong
2018-05-01
Up to now, the mechanism of interface bonding is still not fully understood. This work presents interfacial characteristics of 316LN stainless steel bonding joint after cold compression bonding with subsequent annealing. EBSD analysis shows that fine recrystallization grains preferentially appear near the bonding interface and grow towards both sides of the interface. Transmission electron microscopy reveals that initial cold compression bonding disintegrates the native oxide scales and brings pristine metal from both sides of the interface come into intimate contact, while the broken oxide particles are remained at the original interface. The results indicate that partial bonding can be achieved by cold compression bonding with post-annealing treatment and recrystallization firstly occurs along the bonding interface. However, the interfacial oxides impede the recrystallization grains step over the interface and hinder the complete healing of the bonding interface.
Factors concerned in the efficient steam sterilization of surgical dressings
Fallon, R. J.
1961-01-01
Some of the factors affecting the efficient steam sterilization of dressings have been examined. A jacketed sterilizer will process a load more quickly than a sterilizer without a jacket. The level of fore-vacuum is critical and must reach an absolute pressure of 20 mm. Hg (29·2 in.Hg vacuum) or less. This will overcome all conditions of overpacking studied. The level of after-vacuum should be 100 mm. Hg absolute or less, preferably near 50 mm. Hg absolute. Overpacking cannot be defined in terms of weight of a fabric per unit volume of container but occurs when a load is compressed in its container. PMID:13891475
Compression of a mixed antiproton and electron non-neutral plasma to high densities
NASA Astrophysics Data System (ADS)
Aghion, Stefano; Amsler, Claude; Bonomi, Germano; Brusa, Roberto S.; Caccia, Massimo; Caravita, Ruggero; Castelli, Fabrizio; Cerchiari, Giovanni; Comparat, Daniel; Consolati, Giovanni; Demetrio, Andrea; Di Noto, Lea; Doser, Michael; Evans, Craig; Fanì, Mattia; Ferragut, Rafael; Fesel, Julian; Fontana, Andrea; Gerber, Sebastian; Giammarchi, Marco; Gligorova, Angela; Guatieri, Francesco; Haider, Stefan; Hinterberger, Alexander; Holmestad, Helga; Kellerbauer, Alban; Khalidova, Olga; Krasnický, Daniel; Lagomarsino, Vittorio; Lansonneur, Pierre; Lebrun, Patrice; Malbrunot, Chloé; Mariazzi, Sebastiano; Marton, Johann; Matveev, Victor; Mazzotta, Zeudi; Müller, Simon R.; Nebbia, Giancarlo; Nedelec, Patrick; Oberthaler, Markus; Pacifico, Nicola; Pagano, Davide; Penasa, Luca; Petracek, Vojtech; Prelz, Francesco; Prevedelli, Marco; Rienaecker, Benjamin; Robert, Jacques; Røhne, Ole M.; Rotondi, Alberto; Sandaker, Heidi; Santoro, Romualdo; Smestad, Lillian; Sorrentino, Fiodor; Testera, Gemma; Tietje, Ingmari C.; Widmann, Eberhard; Yzombard, Pauline; Zimmer, Christian; Zmeskal, Johann; Zurlo, Nicola; Antonello, Massimiliano
2018-04-01
We describe a multi-step "rotating wall" compression of a mixed cold antiproton-electron non-neutral plasma in a 4.46 T Penning-Malmberg trap developed in the context of the AEḡIS experiment at CERN. Such traps are routinely used for the preparation of cold antiprotons suitable for antihydrogen production. A tenfold antiproton radius compression has been achieved, with a minimum antiproton radius of only 0.17 mm. We describe the experimental conditions necessary to perform such a compression: minimizing the tails of the electron density distribution is paramount to ensure that the antiproton density distribution follows that of the electrons. Such electron density tails are remnants of rotating wall compression and in many cases can remain unnoticed. We observe that the compression dynamics for a pure electron plasma behaves the same way as that of a mixed antiproton and electron plasma. Thanks to this optimized compression method and the high single shot antiproton catching efficiency, we observe for the first time cold and dense non-neutral antiproton plasmas with particle densities n ≥ 1013 m-3, which pave the way for an efficient pulsed antihydrogen production in AEḡIS.
Process Options for Nominal 2-K Helium Refrigeration System Designs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peter Knudsen, Venkatarao Ganni
Nominal 2-K helium refrigeration systems are frequently used for superconducting radio frequency and magnet string technologies used in accelerators. This paper examines the trade-offs and approximate performance of four basic types of processes used for the refrigeration of these technologies; direct vacuum pumping on a helium bath, direct vacuum pumping using full or partial refrigeration recovery, cold compression, and hybrid compression (i.e., a blend of cold and warm sub-atmospheric compression).
Pach, Daniel; Knöchel, Bettina; Lüdtke, Rainer; Wruck, Katja; Willich, Stefan N; Witt, Claudia M
To compare the efficacy of applying hot dry air versus dry air at room temperature to the throat of patients with a newly acquired common cold using a symptom severity score. A randomised single-blind controlled trial with a treatment duration of 3 days and a follow-up period of 4 days was conducted at a sauna in Berlin, Germany. Between November 2007 and March 2008 and between September 2008 and April 2009, 157 patients with symptoms of the common cold were randomly assigned to an intervention group (n=80) and a control group (n=77). Participants in the intervention group inhaled hot dry air within a hot sauna, dressed in a winter coat, whereas participants in the control group inhaled dry air at room temperature within a hot sauna, also dressed in a winter coat. Area under the curve (AUC) summarising symptom severity over time (Days 2, 3, 5 and 7), symptom severity scores for individual days, intake of medication for the common cold and general ill feeling. No significant difference between groups was observed for AUC representing symptom severity over time (intervention group mean, 31.2 [SEM, 1.8]; control group mean, 35.1 [SEM, 2.3]; group difference, -3.9 [95% CI, -9.7 to 1.9]; P=0.19). However, significant differences between groups were found for medication use on Day 1 (P=0.01), symptom severity score on Day 2 (P=0.04), and participants' ratings of the effectiveness of the therapy on Day 7 (P=0.03). Inhaling hot air while in a sauna has no significant impact on overall symptom severity of the common cold. ClinicalTrials.gov identifier NCT00552981.
Behaviour of thin-walled cold-formed steel members in eccentric compression
NASA Astrophysics Data System (ADS)
Ungureanu, Viorel; Kotełko, Maria; Borkowski, Łukasz; Grudziecki, Jan
2018-01-01
Thin-walled cold-formed steel structures are usually made of members of class 4 cross-sections. Since these sections are prematurely prone to local or distortional buckling and due to the fact they do not have a real post-elastic capacity, the failure at ultimate stage of those members, either in compression or bending, always occurs by forming a local plastic mechanism. The present paper investigates the evolution of the plastic mechanisms and the possibility to use them to characterise the ultimate strength of short thin-walled cold-formed steel members subjected to eccentric compression about minor axis, particularly for members with lipped channel cross-section. Five different types of plastic mechanisms for members in compression with different eccentricities are identified and examined on the basis of FE numerical simulations. Preliminary results of experimental validation of numerical results are presented. The research is based on previous studies and some new investigations of the authors.
Baylis, James R; St John, Alexander E; Wang, Xu; Lim, Esther B; Statz, Matthew L; Chien, Diana; Simonson, Eric; Stern, Susan A; Liggins, Richard T; White, Nathan J; Kastrup, Christian J
2016-09-01
Hemorrhage is the leading cause of preventable death in trauma, and hemorrhage from noncompressible junctional anatomic sites is particularly difficult to control. The current standard is QuikClot Combat Gauze packing, which requires 3 min of compression. We have created a novel dressing with calcium carbonate microparticles that can disperse and self-propel upstream against flowing blood. We loaded these microparticles with thrombin and tranexamic acid and tested their efficacy in a swine arterial bleeding model without wound compression. Anesthetized immature female swine received 5 mm femoral arteriotomies to induce severe junctional hemorrhage. Wounds were packed with kaolin-based QuikClot Combat Gauze (KG), propelled thrombin-microparticles with protonated tranexamic acid (PTG), or a non-propelling formulation of the same thrombin-microparticles with non-protonated tranexamic acid (NPTG). Wounds were not compressed after packing. Each animal then received one 15 mL/kg bolus of hydroxyethyl starch solution followed by Lactated Ringer as needed for hypotension (maximum: 100 mL/kg) for up to 3 h. Survival was improved with PTG (3-h survival: 8/8, 100%) compared with KG (3/8, 37.5%) and NPTG (2/8, 25%) (P <0.01). PTG animals maintained lower serum lactate and higher hemoglobin concentrations than NPTG (P <0.05) suggesting PTG decreased severity of subsequent hemorrhagic shock. However, total blood loss, Lactated Ringer infusion volumes, and mean arterial pressures of surviving animals were not different between groups (P >0.05). Thus, in this swine model of junctional arterial hemorrhage, gauze with self-propelled, prothrombotic microparticles improved survival and 2 indicators of hemorrhagic shock when applied without compression, suggesting this capability may enable better treatment of non-compressible junctional wounds.
Elastic adhesive dressing treatment of bleeding wounds in trauma victims.
Naimer, S A; Chemla, F
2000-11-01
Conventional methods for hemorrhage control in the trauma patient fall short of providing a full solution for the life-threatening bleeding injury. The tourniquet is limited specifically to injuries of the distal limbs. Local pressure or tight bandaging with military bandages is cumbersome and often insufficient. Therefore, we sought a superior method to stop bleeding in emergency situations. Our objective is report and description of our experience with this method. Since 1992 our trauma team repeatedly encountered multiple trauma victims presenting with bleeding wounds. We achieved hemorrhage control by means of an adhesive elastic bandage applied directly over a collection of 4 x 4 gauze pads placed on the wound surface. The roll is then wrapped around the body surface, over the bleeding site, until sufficient pressure is reached to terminate ongoing hemorrhage. Three typical cases are described in detail. Adhesive elastic dressing compression was successful in fully controlling bleeding without compromise of distal blood flow. Our method corresponded to the demand for an immediate, effective and lasting form of hemorrhage control without complications. Furthermore, this technique proved successful even over body surfaces normally recognized as difficult to compress. We experienced equal favorable success while working during transit by either ambulance or helicopter transportation. We find our preliminary experience using elastic adhesive dressing for bleeding control encouraging and suggest that this may substitute existing practices as the selected treatment when indicated. This method is presently underrecognized for this purpose. Development of a single unit bandage may further enhance success in the future.
Bennett, Brad L; Littlejohn, Lanny F; Kheirabadi, Bijan S; Butler, Frank K; Kotwal, Russ S; Dubick, Michael A; Bailey, Jeffrey A
2014-01-01
Hemorrhage remains the leading cause of combat death and a major cause of death from potentially survivable injuries. Great strides have been made in controlling extremity hemorrhage with tourniquets, but not all injuries are amenable to tourniquet application. Topical hemostatic agents and dressings have also contributed to success in controlling extremity and compressible junctional hemorrhage, and their efficacy continues to increase as enhanced products are developed. Since the addition of Combat Gauze™ (Z-Medica Corporation, Wallingford, CT, USA; http://www.z-medica.com/) in April 2008 to the Tactical Combat Casualty Care (TCCC) Guidelines, there are consistent data from animal studies of severe hemorrhage that chitosan-based hemostatic gauze dressings developed for battlefield application are, at least, equally efficacious as Combat Gauze. Successful outcomes are also reported using newer chitosan-based dressings in civilian hospital-based surgical case reports and prehospital (battlefield) case reports and series. Additionally, there have been no noted complications or safety concerns in these cases or across many years of chitosan-based hemostatic dressing use in both the military and civilian prehospital sectors. Consequently, after a decade of clinical use, there is added benefit and a good safety record for using chitosan-based gauze dressings. For these reasons, many specific US military Special Operations Forces, NATO militaries, and emergency medical services (EMS) and law enforcement agencies have already implemented the widespread use of these new recommended chitosan-based hemostatic dressings. Based on the past battlefield success, this report proposes to keep Combat Gauze as the hemostatic dressing of choice along with the new addition of Celox™ Gauze (Medtrade Products Ltd., Crewe, UK; http://www.celoxmedical.com/usa/products /celox-gauze/) and ChitoGauze® (HemCon Medical Technologies, Portland, OR, USA; http://www.hemcon.com/) to the TCCC Guidelines. 2014.
Akit, H; Collins, C L; Fahri, F T; Hung, A T; D'Souza, D N; Leury, B J; Dunshea, F R
2014-03-01
The influence of dietary lecithin at doses of 0, 4, 20 or 80 g/kg fed to finisher gilts for six weeks prior to slaughter on growth performance, carcass quality and pork quality was investigated. M. longissimus lumborum (loin) was removed from 36 pig carcasses at 24h post-mortem for Warner-Bratzler shear force, compression, collagen content and colour analyses. Dietary lecithin increased dressing percentage (P=0.009). Pork chewiness and collagen content were decreased by dietary lecithin (P<0.05, respectively), suggesting that improved chewiness may be due to decreased collagen content. However, dietary lecithin had no effect on shear force, cohesiveness or hardness (P>0.05, respectively). Dietary lecithin reduced loin muscle L* values and increased a* values (P<0.05, respectively) but no changes on b* values (P=0.56). The data showed that dietary lecithin improved dressing percentage and resulted in less chewy and less pale pork. © 2013.
Aerodynamics inside a rapid compression machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mittal, Gaurav; Sung, Chih-Jen
2006-04-15
The aerodynamics inside a rapid compression machine after the end of compression is investigated using planar laser-induced fluorescence (PLIF) of acetone. To study the effect of reaction chamber configuration on the resulting aerodynamics and temperature field, experiments are conducted and compared using a creviced piston and a flat piston under varying conditions. Results show that the flat piston design leads to significant mixing of the cold vortex with the hot core region, which causes alternate hot and cold regions inside the combustion chamber. At higher pressures, the effect of the vortex is reduced. The creviced piston head configuration is demonstratedmore » to result in drastic reduction of the effect of the vortex. Experimental conditions are also simulated using the Star-CD computational fluid dynamics package. Computed results closely match with experimental observation. Numerical results indicate that with a flat piston design, gas velocity after compression is very high and the core region shrinks quickly due to rapid entrainment of cold gases. Whereas, for a creviced piston head design, gas velocity after compression is significantly lower and the core region remains unaffected for a long duration. As a consequence, for the flat piston, adiabatic core assumption can significantly overpredict the maximum temperature after the end of compression. For the creviced piston, the adiabatic core assumption is found to be valid even up to 100 ms after compression. This work therefore experimentally and numerically substantiates the importance of piston head design for achieving a homogeneous core region inside a rapid compression machine. (author)« less
Compression Dressing Using Dental Impression Compound for Conservative Management of Sialocele.
Kudva, Adarsh; Carriappa, K M; Kamath, Abhay; Chithra, A
2016-12-01
A Sialocele or salivary pseudocyst is due to extravasation of saliva into periglandular tissue due to disruption of gland parenchyma. Various techniques of management have been described in literature; both conservative and surgical management have been documented. We report a simple economical and efficient method to deal with sailocele presenting after neck dissection.
Preparing for Hiking and Rock-Climbing At Altitude
NASA Technical Reports Server (NTRS)
Greenleaf, John E.
2002-01-01
Exposure to altitude with or without exercise usually results in body dehydration. Psychological and physiological preparation for exercise at altitude involves consideration of maintaining body warmth in a cool to cold environment with progressively lower oxygen content (partial pressure) as altitude increases. However, this discussion will focus on altitudes below 14,000 it where supplemental breathing oxygen is not required for sojourns of healthy people. Background information and helpful advice for those who exercise in the cold can be found in selected articles in the 2001 Winter Issue of this Newsletter: M.B. Ducharme, Get ready for outdoor winter play: prepare yourself for the cold; C. O'Brien, Think layers when dressing for exercise in the cold; B.G. Rice and R. Ellis, Let it snow, let it snow, let it snow - but be aware of winter hazards; and L.B. Mayers, Exercise - induced asthma.
The impact of weather on women's tendency to wear red or pink when at high risk for conception.
Tracy, Jessica L; Beall, Alec T
2014-01-01
Women are particularly motivated to enhance their sexual attractiveness during their most fertile period, and men perceive shades of red, when associated with women, as sexually attractive. Building on this research, we recently found that women are more likely to wear reddish clothing when at peak fertility (Beall & Tracy, 2013), presumably as a way of increasing their attractiveness. Here, we first report results from a methodological replication, conducted during warmer weather, which produced a null effect. Investigating this discrepancy, we considered the impact of a potentially relevant contextual difference between previous research and the replication: current weather. If the red-dress effect is driven by a desire to increase one's sexual appeal, then it should emerge most reliably when peak-fertility women have few alternative options for accomplishing this goal (e.g., wearing minimal clothing). Results from re-analyses of our previously collected data and a new experiment support this account, by demonstrating that the link between fertility and red/pink dress emerges robustly in cold, but not warm, weather. Together, these findings suggest that the previously documented red-dress effect is moderated by current climate concerns, and provide further evidence that under certain circumstances red/pink dress is reliably associated with female fertility.
DEVELOPMENT OF COLD CLIMATE HEAT PUMP USING TWO-STAGE COMPRESSION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Rice, C Keith; Abdelaziz, Omar
2015-01-01
This paper uses a well-regarded, hardware based heat pump system model to investigate a two-stage economizing cycle for cold climate heat pump applications. The two-stage compression cycle has two variable-speed compressors. The high stage compressor was modelled using a compressor map, and the low stage compressor was experimentally studied using calorimeter testing. A single-stage heat pump system was modelled as the baseline. The system performance predictions are compared between the two-stage and single-stage systems. Special considerations for designing a cold climate heat pump are addressed at both the system and component levels.
1990-07-01
heat stress. The ambient temperature for this condition (12.8 C) was determined by calculating its thermal comfort equivalence with another control...condition in which only the Battle Dress Uniform (BDU) was worn (21.1 C). The matching of the two conditions for thermal comfort enables differences
Striking a Memory the Right Way
ERIC Educational Resources Information Center
Elrick, Mike
2010-01-01
The author has strong childhood memories of sitting on the ledge of an open fireplace after a bath on a cold winter's evening. While the logs crackled and sizzled, he and his brothers would toast their pajamas on the screen and slowly dress themselves before bed. Those are good memories for him. So it was with great joy that he recently bought a…
[Ambulant compression therapy for crural ulcers; an effective treatment when applied skilfully].
de Boer, Edith M; Geerkens, Maud; Mooij, Michael C
2015-01-01
The incidence of crural ulcers is high. They reduce quality of life considerably and create a burden on the healthcare budget. The key treatment is ambulant compression therapy (ACT). We describe two patients with crural ulcers whose ambulant compression treatment was suboptimal and did not result in healing. When the bandages were applied correctly healing was achieved. If correctly applied ACT should provide sufficient pressure to eliminate oedema, whilst taking local circumstances such as bony structures and arterial qualities into consideration. To provide pressure-to-measure regular practical training, skills and regular quality checks are needed. Knowledge of the properties of bandages and the proper use of materials for padding under the bandage enables good personalised ACT. In trained hands adequate compression and making use of simple bandages and dressings provides good care for patients suffering from crural ulcers in contrast to inadequate ACT using the same materials.
Hydrofluoric acid burn resulting from ignition of gas from a compressed air duster.
Foster, Kevin N; Jones, LouAnn; Caruso, Daniel M
2003-01-01
A young female suffered burns to her hand after the ignition of gas from a compressed air duster. After debridement and dressing, the patient continued to have pain out of proportion to injury that was refractory to intravenous morphine. The material safety data sheet revealed that the chemical used was 1,1-difluoroethane. High temperatures can cause decompensation to form hydrofluoric acid. Calcium gluconate gel was applied topically to the patient's burns, which caused prompt and complete relief of her pain. A review of different compressed air duster products revealed that the main ingredient in each was a halogenated hydrocarbon. Although not considered flammable, all products have warnings regarding the possibility of ignition under various circumstances. Ignition of the gas in compressed air cleaners not only can cause flame burns, it can also cause chemical damage from exposure to hydrogen and fluoride ions. Prompt recognition and treatment is necessary to prevent severe injury.
Tawfick, Wael A; Sultan, Sherif
2013-01-01
Topical wound oxygen (TWO(2)) proposes an option in the management of refractory nonhealing venous ulcers (RVUs). End points are proportion of ulcers healed at 12 weeks, recurrence rates, reduction in ulcer size, and time to full healing. A total of 67 patients with RVU were managed using TWO(2) and 65 patients with conventional compression dressings (CCDs) for 12 weeks or till full healing. Mean reduction in ulcer surface area at 12 weeks was 96% in patients managed with TWO(2) and 61% in patients managed with CCD. At 12 weeks, 76% of the TWO(2)-managed ulcers had completely healed, compared to 46% of the CCD-managed ulcers (P < .0001). Median time to full healing was 57 days in patients managed with TWO(2) and 107 days in patients managed with CCD (P< .0001). After 36 months follow-up, 14 of the 30 healed CCD ulcers showed recurrence compared to 3 of the 51 TWO(2)-healed ulcers. The TWO(2) is effective and valuable in managing RVU. The TWO(2) slashes the time required for RVU healing and radically decreases the recurrence rates.
Sub-bandage sensing system for remote monitoring of chronic wounds in healthcare
NASA Astrophysics Data System (ADS)
Hariz, Alex; Mehmood, Nasir; Voelcker, Nico
2015-12-01
Chronic wounds, such as venous leg ulcers, can be monitored non-invasively by using modern sensing devices and wireless technologies. The development of such wireless diagnostic tools may improve chronic wound management by providing evidence on efficacy of treatments being provided. In this paper we present a low-power portable telemetric system for wound condition sensing and monitoring. The system aims at measuring and transmitting real-time information of wound-site temperature, sub-bandage pressure and moisture level from within the wound dressing. The system comprises commercially available non-invasive temperature, moisture, and pressure sensors, which are interfaced with a telemetry device on a flexible 0.15 mm thick printed circuit material, making up a lightweight biocompatible sensing device. The real-time data obtained is transmitted wirelessly to a portable receiver which displays the measured values. The performance of the whole telemetric sensing system is validated on a mannequin leg using commercial compression bandages and dressings. A number of trials on a healthy human volunteer are performed where treatment conditions were emulated using various compression bandage configurations. A reliable and repeatable performance of the system is achieved under compression bandage and with minimal discomfort to the volunteer. The system is capable of reporting instantaneous changes in bandage pressure, moisture level and local temperature at wound site with average measurement resolutions of 0.5 mmHg, 3.0 %RH, and 0.2 °C respectively. Effective range of data transmission is 4-5 m in an open environment.
Hasegawa, Yoshihiro; Kanda, Hideki; Miki, Manabu; Masui, Satoru; Yoshio, Yuko; Yamada, Yasushi; Soga, Norihito; Arima, Kiminobu; Sugimura, Yoshiki
2013-10-01
A 48-year-old married woman complaining of macroscopic hematuria and cystitis symptom was admitted to our institute. Flexible cystoscopy revealed many yellowish, nodular masses at the paries posterior of the urinary bladder, and cold-punch biopsy proved it to be amyloidosis. Serum amyloid protein A (SAA) was high, and suggested systemic amyloidosis. Renal biopsy and colon fiberscopy did not reveal any abnormalities. We therefore diagnosed a primary localized amyloidosis of the urinary bladder. Transurethral resection and dimethyl sulfoxide (DMSO) infusion therapy are used to treat amyloidosis of the urinary bladder. However there is no definite cure for amyloidosis of the urinary bladder. Therefore we selected DMSO occlusive dressing technique therapy. After 5 years of therapy, there was no evidence of a recurrence of amyloidosis.
Tips for Energy Savers In and Around the Home, On the Road, In the Marketplace. Don't Be Fuelish.
ERIC Educational Resources Information Center
Federal Energy Administration, Washington, DC.
This pamphlet presents simple suggestions for energy conservation. Sections include: (1) In and around the home; (2) Using the family car; and (3) In the marketplace. The suggestions given are mostly common sense tips like dressing appropriately for either hot or cold weather, use electrical appliances and lights sparingly and at off-peak times,…
Prospective Study of Burn Wound Excision of the Hands
1983-06-01
Houston, Texas. sion (10, 11). This method allows the sequential removal Presented at the Forty-second Annual Session of The American of nonviable tissue...ultrasonography. Es- days, after which all dressings were removed and a more charotomies of upper extremities were carried out if vigorous physical therapy...sponges, followed by mild compression wrapping and interphalangeal joints. The thumb was abducted and elevation. Electrocoagulation of bleeding points
Amjad, Khurram; Asquith, David; Sebastian, Christopher M.; Wang, Wei-Chung
2017-01-01
This article presents an experimental study on the fatigue behaviour of cracks emanating from cold-expanded holes utilizing thermoelastic stress analysis (TSA) and synchrotron X-ray diffraction (SXRD) techniques with the aim of resolving the long-standing ambiguity in the literature regarding potential relaxation, or modification, of beneficial compressive residual stresses as a result of fatigue crack propagation. The crack growth rates are found to be substantially lower as the crack tip moved through the residual stress zone induced by cold expansion. The TSA results demonstrated that the crack tip plastic zones were reduced in size by the presence of the residual compressive stresses induced by cold expansion. The crack tip plastic zones were found to be insignificant in size in comparison to the residual stress zone resulting from cold expansion, which implied that they were unlikely to have had a notable impact on the surrounding residual stresses induced by cold expansion. The residual stress distributions measured along the direction of crack growth, using SXRD, showed no signs of any significant stress relaxation or redistribution, which validates the conclusions drawn from the TSA data. Fractographic analysis qualitatively confirmed the influence on crack initiation of the residual stresses induced by the cold expansion. It was found that the application of single compressive overload caused a relaxation, or reduction in the residual stresses, which has wider implications for improving the fatigue life. PMID:29291095
The effect of age, genotype and sex on carcass traits, meat quality and sensory attributes of geese
2018-01-01
Objective The aim of this study was to compare carcass traits, meat quality and sensory attributes in two different genotypes of geese according to age and sex. Methods The experiment was carried out on 160 birds of two genotypes of geese: the Czech Goose (CG) breed and a Eskildsen Schwer (ES) hybrid. One-d-old goslings were divided into four groups according to genotype and sex. Two dates for slaughtering (at 8 and 16 wk of age of goslings) were undertaken. Results The slaughter weight, cold carcass weight and dressing percentage were affected by all the studied factors, and significant interactions between age, genotype and sex were detected in the slaughter weight (p<0.001) and cold carcass weight (p = 0.004). The pH was not affected by any of studied factors, whereas in terms of meat colour parameters there were observed significant effects of age on L* and b* value and a significant effect of sex on a* value. The meat fat content was higher (p = 0.002) in ES. Higher score for overall acceptance of goose meat was recorded for ES at both ages compared to CG. Conclusion ES had higher dressing percentage and better sensory attributes, whereas CG exceled in the favourable nutritional value of the meat. PMID:28823138
A System Approach to Navy Medical Education and Training. Appendix 15. Biotronics Technicians.
1974-08-31
curricula based upon job analysis was implemented to a level of methodology determination. These methods and curriculum materials constituted a third...Therapy Technician 8495 Dermatology Technician 8496 Embalming Technician 8497 Medical Illustration Technician 8498 Medical Equipment Repair Technician... WET COMPRESSES/SOAKS/PACKS 24 ICONTROL BLEEDING BY PRESSURE DRESSING 25 1APPLY/CHANGE BANDAGES, E.G. ROLLER, TRIANGULAR, KURLEX GO TO RIGHT HAND PAGE
Recent developments in trapping and manipulation of atoms with adiabatic potentials
NASA Astrophysics Data System (ADS)
Garraway, Barry M.; Perrin, Hélène
2016-09-01
A combination of static and oscillating magnetic fields can be used to ‘dress’ atoms with radio-frequency (RF), or microwave, radiation. The spatial variation of these fields can be used to create an enormous variety of traps for ultra-cold atoms and quantum gases. This article reviews the type and character of these adiabatic traps and the applications which include atom interferometry and the study of low-dimensional quantum systems. We introduce the main concepts of magnetic traps leading to adiabatic dressed traps. The concept of adiabaticity is discussed in the context of the Landau-Zener model. The first bubble trap experiment is reviewed together with the method used for loading it. Experiments based on atom chips show the production of double wells and ring traps. Dressed atom traps can be evaporatively cooled with an additional RF field, and a weak RF field can be used to probe the spectroscopy of the adiabatic potentials. Several approaches to ring traps formed from adiabatic potentials are discussed, including those based on atom chips, time-averaged adiabatic potentials and induction methods. Several proposals for adiabatic lattices with dressed atoms are also reviewed.
Exotic topological density waves in cold atomic Rydberg-dressed fermions
Li, Xiaopeng; Sarma, S Das
2015-01-01
Versatile controllability of interactions in ultracold atomic and molecular gases has now reached an era where quantum correlations and unconventional many-body phases can be studied with no corresponding analogues in solid-state systems. Recent experiments in Rydberg atomic gases have achieved exquisite control over non-local interactions, allowing novel quantum phases unreachable with the usual local interactions in atomic systems. Here we study Rydberg-dressed atomic fermions in a three-dimensional optical lattice predicting the existence of hitherto unheard-of exotic mixed topological density wave phases. By varying the spatial range of the non-local interaction, we find various chiral density waves with spontaneous time-reversal symmetry breaking, whose quasiparticles form three-dimensional quantum Hall and Weyl semimetal states. Remarkably, certain density waves even exhibit mixed topologies beyond the existing topological classification. Our results suggest gapless fermionic states could exhibit far richer topology than previously expected. PMID:25972134
Inductively guided circuits for ultracold dressed atoms
Sinuco-León, German A.; Burrows, Kathryn A.; Arnold, Aidan S.; Garraway, Barry M.
2014-01-01
Recent progress in optics, atomic physics and material science has paved the way to study quantum effects in ultracold atomic alkali gases confined to non-trivial geometries. Multiply connected traps for cold atoms can be prepared by combining inhomogeneous distributions of DC and radio-frequency electromagnetic fields with optical fields that require complex systems for frequency control and stabilization. Here we propose a flexible and robust scheme that creates closed quasi-one-dimensional guides for ultracold atoms through the ‘dressing’ of hyperfine sublevels of the atomic ground state, where the dressing field is spatially modulated by inductive effects over a micro-engineered conducting loop. Remarkably, for commonly used atomic species (for example, 7Li and 87Rb), the guide operation relies entirely on controlling static and low-frequency fields in the regimes of radio-frequency and microwave frequencies. This novel trapping scheme can be implemented with current technology for micro-fabrication and electronic control. PMID:25348163
NASA Astrophysics Data System (ADS)
Lu, Bohan; Lu, Xiaohui
2018-02-01
This study investigates the correlation between the residual stress and distortion behavior of a cold-rolled ring from the annealing to quenching-tempering (QT) process. Due to the cold-rolled process, the external periphery of the bearing ring experiences a compressive residual stress. To relieve the residual stress, cold-rolled rings are annealed at 700 °C which is higher than the starting temperature of recrystallization. When cold-rolled rings are annealed at 700 °C for 15 min, the compressive residual stress is reduced to zero and the outer diameter of the annealed ring becomes larger than that of a non-annealed sample, which is unrelated to annealing time. Simultaneously, the roundness and taper deviation do not obviously change compared with those of non-annealed sample. The stress relaxation during the annealing process was attributed to the recovery and recrystallization of ferrite. Annealing has a genetic influence on the following QT heat treatment, wherein the lowest residual stress is in the non-annealed cold-rolled ring. From the annealing to QT process, the deviation of the outer diameter, roundness, and taper increased with annealing time, a large extend than that of non-annealed samples.
Development of a hybrid chemical/mechanical heat pump
NASA Technical Reports Server (NTRS)
Grzyll, Lawrence R.; Silvestri, John J.; Scaringe, Robert P.
1991-01-01
The authors present the current development status of a hybrid chemical/mechanical heat pump for low-lift applications. The heat pump provides electronics cooling by evaporating a pure refrigerant from an absorbent/refrigerant mixture in a generator/cold plate. The current development focused on evaluation of absorbent/refrigerant pairs, corrosion testing, pump and compressor design, and electronic cold plate design. Two cycle configurations were considered. The first configuration utilized a standard mechanical compressor and pump. The second cycle configuration investigated pumps and compressors with non-moving parts. An innovative generator/cold plate design is also presented. The development to date shows that this cycle has about the same performance as standard vapor compression heat pumps with standard refrigerants but may have some performance and reliability advantages over vapor compression heat pumps.
Oblique ion-acoustic cnoidal waves in two temperature superthermal electrons magnetized plasma
NASA Astrophysics Data System (ADS)
Panwar, A.; Ryu, C. M.; Bains, A. S.
2014-12-01
A study is presented for the oblique propagation of ion acoustic cnoidal waves in a magnetized plasma consisting of cold ions and two temperature superthermal electrons modelled by kappa-type distributions. Using the reductive perturbation method, the nonlinear Korteweg de-Vries equation is derived, which further gives the solutions with a special type of cnoidal elliptical functions. Both compressive and rarefactive structures are found for these cnoidal waves. Nonlinear periodic cnoidal waves are explained in terms of plasma parameters depicting the Sagdeev potential and the phase curves. It is found that the density ratio of hot electrons to ions μ significantly modifies compressive/refractive wave structures. Furthermore, the combined effects of superthermality of cold and hot electrons κ c , κ h , cold to hot electron temperature ratio σ, angle of propagation and ion cyclotron frequency ωci have been studied in detail to analyze the height and width of compressive/refractive cnoidal waves. The findings in the present study could have important implications in understanding the physics of electrostatic wave structures in the Saturn's magnetosphere where two temperature superthermal electrons are present.
Fan, Senqing; Xiao, Zeyi; Li, Minghai
2016-07-01
An energy efficient pervaporation membrane bioreactor with mechanical vapor compression was developed for ethanol recovery during the process of fermentation coupled with pervaporation. Part of the permeate vapor at the membrane downstream under the vacuum condition was condensed by running water at the first condenser and the non-condensed vapor enriched with ethanol was compressed to the atmospheric pressure and pumped into the second condenser, where the vapor was easily condensed into a liquid by air. Three runs of fermentation-pervaporation experiment have been carried out lasting for 192h, 264h and 360h respectively. Complete vapor recovery validated the novel pervaporation membrane bioreactor. The total flux of the polydimethylsiloxane (PDMS) membrane was in the range of 350gm(-2)h(-1) and 600gm(-2)h(-1). Compared with the traditional cold traps condensation, mechanical vapor compression behaved a dominant energy saving feature. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of Combat Gauze and TraumaStat in Two Severe Groin Injury Models
2011-07-01
especially given their similarity in form to stan· dard gauze currently in use . Recently, two such prod· ucts, Combat Gauze (CBG) and TraumaStat (TMS...if acted upon imme- diately after injury. With proper compression on the wound site, use of adequate hemostatic dressing for bleeding control...be minimized. In an effort for better hemo- static control in noncompressible areas such as the neck or the groin where tourniquets cannot be used
[History of the therapeutic uses of the tinder polypore, Fomes fomentarius (L. : Fr].
Roussel, Bertrand; Rapior, Sylvie; Charlot, Colette; Masson, Christian-Louis; Boutié, Paul
2002-01-01
This paper presents the major therapeutic uses of Fomes fomentarius (L. : Fr.) Fr., tinder polypore. The context of this fungus is a wooly and soft material so called amadou (tinder). During the XVIII and XIXth centuries, the fungal material was used as haemostatic dressing and bandage to keep the temperature and compress parts of the body. It was also used as cautery for moxibustion and was reported in several traditional pharmacopoeias (Hungarian, Chinese, Indian).
4. FIRST FLOOR INTERIOR, AMMONIA COMPRESSION DYNAMOS IN MACHINERY ROOM ...
4. FIRST FLOOR INTERIOR, AMMONIA COMPRESSION DYNAMOS IN MACHINERY ROOM ALONG SOUTH SIDE OF WESTERN PORTION OF BUILDING, FROM EASTERN ENTRANCE TO MACHINERY ROOM, LOOKING WEST. - Oakland Naval Supply Center, Cold Storage Warehouse, South of C Street between First & Second Street, Oakland, Alameda County, CA
Active wound dressings based on bacterial nanocellulose as drug delivery system for octenidine.
Moritz, Sebastian; Wiegand, Cornelia; Wesarg, Falko; Hessler, Nadine; Müller, Frank A; Kralisch, Dana; Hipler, Uta-Christina; Fischer, Dagmar
2014-08-25
Although bacterial nanocellulose (BNC) may serve as an ideal wound dressing, it exhibits no antibacterial properties by itself. Therefore, in the present study BNC was functionalized with the antiseptic drug octenidine. Drug loading and release, mechanical characteristics, biocompatibility, and antimicrobial efficacy were investigated. Octenidine release was based on diffusion and swelling according to the Ritger-Peppas equation and characterized by a time dependent biphasic release profile, with a rapid release in the first 8h, followed by a slower release rate up to 96 h. The comparison between lab-scale and up-scale BNC identified thickness, water content, and the surface area to volume ratio as parameters which have an impact on the control of the release characteristics. Compression and tensile strength remained unchanged upon incorporation of octenidine in BNC. In biological assays, drug-loaded BNC demonstrated high biocompatibility in human keratinocytes and antimicrobial activity against Staphylococcus aureus. In a long-term storage test, the octenidine loaded in BNC was found to be stable, releasable, and biologically active over a period of 6 months without changes. In conclusion, octenidine loaded BNC presents a ready-to-use wound dressing for the treatment of infected wounds that can be stored over 6 months without losing its antibacterial activity. Copyright © 2014 Elsevier B.V. All rights reserved.
Rapid and selective brain cooling method using vortex tube: A feasibility study.
Bakhsheshi, Mohammad Fazel; Keenliside, Lynn; Lee, Ting-Yim
2016-05-01
Vortex tubes are simple mechanical devices to produce cold air from a stream of compressed air without any moving parts. The primary focus of the current study is to investigate the feasibility and efficiency of nasopharyngeal brain cooling method using a vortex tube. Experiments were conducted on 5 juvenile pigs. Nasopharygeal brain cooling was achieved by directing cooled air via a catheter in each nostril into the nasal cavities. A vortex tube was used to generate cold air using various sources of compressed air: (I) hospital medical air outlet (n = 1); (II) medical air cylinders (n = 3); and (III) scuba (diving) cylinders (n = 1). By using compressed air from a hospital medical air outlet at fixed inlet pressure of 50 PSI, maximum brain-rectal temperature gradient of -2°C was reached about 45-60 minutes by setting the flow rate of 25 L/min and temperature of -7°C at the cold air outlet. Similarly, by using medical air cylinders at fill-pressure of 2265 PSI and down regulate the inlet pressure to the vortex tube to 50 PSI, brain temperature could be reduced more rapidly by blowing -22°C ± 2°C air at a flow rate of 50 L/min; brain-body temperature gradient of -8°C was obtained about 30 minutes. Furthermore, we examined scuba cylinders as a portable source of compressed gas supply to the vortex tube. Likewise, by setting up the vortex tube to have an inlet pressure of 25 PSI and 50 L/min and -3°C at the cold air outlet, brain temperature decreased 4.5°C within 10-20 min. Copyright © 2016 Elsevier Inc. All rights reserved.
In Situ Bioremediation of Chlorinated Solvent Source Areas with Enhanced Mass Transfer
2008-09-01
immerse in cold water. Do not apply ointment , grease or Vaseline. Cover burns with thick, dry sterile dressings. Keep burned feet or legs elevated...about six to eight barrels per month of waste TCE and POL may have been disposed. These materials were also used to aid in burning other wastes...These consist of man-made fill in the trench areas and include debris and burned material. These materials typically extend to less than 12 ft bgs
Electrical resistance determination of actual contact area of cold welded metal joints
NASA Technical Reports Server (NTRS)
Hordon, M. J.
1970-01-01
Method measures the area of the bonded zone of a compression weld by observing the electrical resistance of the weld zone while the load changes from full compression until the joint ruptures under tension. The ratio of bonding force to maximum tensile load varies considerably.
One dimensional magneto-optical compression of a cold CaF molecular beam
NASA Astrophysics Data System (ADS)
Chae, Eunmi; Anderegg, Loic; Augenbraun, Benjamin; Ravi, Aakash; Hemmerling, Boerge; Hutzler, Nicholas; Collopy, Alejandra; Ye, Jun; Ketterle, Wolfgang; Doyle, John
2017-04-01
We demonstrate one dimensional, transverse magneto-optical compression of a cold beam of calcium monofluoride (CaF). By continually alternating the magnetic field direction and laser polarizations of the magneto-optical force (RF-MOT), a photon scattering rate of 2 π x 0.4 MHz is achieved. A 3D model for this RF-MOT, validated by agreement with data, predicts a 3D RF-MOT capture velocity for CaF of 5 m/s. This work was supported by the ARO, the CUA, and the NSF. BLA is supported by the National Science Foundation Graduate Research Fellowship under NSF Grant No. DGE1144152.
Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganni, Venkatarao; Knudsen, Peter N.; Arenius, Dana M.
The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system.
NASA Astrophysics Data System (ADS)
Sova, A.; Courbon, C.; Valiorgue, F.; Rech, J.; Bertrand, Ph.
2017-12-01
In this paper, an experimental study of influence of machining by turning and ball burnishing on the surface morphology, structure and residual stress distribution of cold spray 17-4 PH stainless steel deposits is provided. It is shown that cold spray deposits could be machined by turning under parameters closed to turning of bulk 17-4 PH stainless steel. Ball burnishing process permits to decrease surface roughness. Cross-sectional observation revealed that the turning and ball burnishing process allowed microstructure changes in the coating near-surface zone. In particular, significant particle deformation and particle boundary fragmentation is observed. Measurements of residual stresses showed that residual stresses in the as-spray deposit are compressive. After machining by turning, tensile residual stresses in the near-surface zone were induced. Further surface finishing of turned coating by ball burnishing allowed the establishment of the compressive residual stresses in the coating.
Turbulence statistics with quantified uncertainty in cold-wall supersonic channel flow
NASA Astrophysics Data System (ADS)
Ulerich, Rhys; Moser, Robert D.
2012-11-01
To investigate compressibility effects in wall-bounded turbulence, a series of direct numerical simulations of compressible channel flow with isothermal (cold) walls have been conducted. All combinations of Re = { 3000 , 5000 } and Ma = { 0 . 1 , 0 . 5 , 1 . 5 , 3 . 0 } have been simulated where the Reynolds and Mach numbers are based on bulk velocity and sound speed at the wall temperature. Turbulence statistics with precisely quantified uncertainties computed from these simulations will be presented and are being made available in a public data base at http://turbulence.ices.utexas.edu/. The simulations were performed using a new pseudo-spectral code called Suzerain, which was designed to efficiently produce high quality data on compressible, wall-bounded turbulent flows using a semi-implicit Fourier/B-spline numerical formulation. This work is supported by the Department of Energy [National Nuclear Security Administration] under Award Number [DE-FC52-08NA28615].
Fabrication and evaluation of cold/formed/weldbrazed beta-titanium skin-stiffened compression panels
NASA Technical Reports Server (NTRS)
Royster, D. M.; Bales, T. T.; Davis, R. C.; Wiant, H. R.
1983-01-01
The room temperature and elevated temperature buckling behavior of cold formed beta titanium hat shaped stiffeners joined by weld brazing to alpha-beta titanium skins was determined. A preliminary set of single stiffener compression panels were used to develop a data base for material and panel properties. These panels were tested at room temperature and 316 C (600 F). A final set of multistiffener compression panels were fabricated for room temperature tests by the process developed in making the single stiffener panels. The overall geometrical dimensions for the multistiffener panels were determined by the structural sizing computer code PASCO. The data presented from the panel tests include load shortening curves, local buckling strengths, and failure loads. Experimental buckling loads are compared with the buckling loads predicted by the PASCO code. Material property data obtained from tests of ASTM standard dogbone specimens are also presented.
Equation of state for shock compression of distended solids
NASA Astrophysics Data System (ADS)
Grady, Dennis; Fenton, Gregg; Vogler, Tracy
2014-05-01
Shock Hugoniot data for full-density and porous compounds of boron carbide, silicon dioxide, tantalum pentoxide, uranium dioxide and playa alluvium are investigated for the purpose of equation-of-state representation of intense shock compression. Complications of multivalued Hugoniot behavior characteristic of highly distended solids are addressed through the application of enthalpy-based equations of state of the form originally proposed by Rice and Walsh in the late 1950's. Additive measures of cold and thermal pressure intrinsic to the Mie-Gruneisen EOS framework is replaced by isobaric additive functions of the cold and thermal specific volume components in the enthalpy-based formulation. Additionally, experimental evidence reveals enhancement of shock-induced phase transformation on the Hugoniot with increasing levels of initial distension for silicon dioxide, uranium dioxide and possibly boron carbide. Methods for addressing this experimentally observed feature of the shock compression are incorporated into the EOS model.
Equation of State for Shock Compression of High Distension Solids
NASA Astrophysics Data System (ADS)
Grady, Dennis
2013-06-01
Shock Hugoniot data for full-density and porous compounds of boron carbide, silicon dioxide, tantalum pentoxide, uranium dioxide and playa alluvium are investigated for the purpose of equation-of-state representation of intense shock compression. Complications of multivalued Hugoniot behavior characteristic of highly distended solids are addressed through the application of enthalpy-based equations of state of the form originally proposed by Rice and Walsh in the late 1950's. Additivity of cold and thermal pressure intrinsic to the Mie-Gruneisen EOS framework is replaced by isobaric additive functions of the cold and thermal specific volume components in the enthalpy-based formulation. Additionally, experimental evidence supports acceleration of shock-induced phase transformation on the Hugoniot with increasing levels of initial distention for silicon dioxide, uranium dioxide and possibly boron carbide. Methods for addressing this experimentally observed facet of the shock compression are introduced into the EOS model.
NASA Astrophysics Data System (ADS)
Lundblad, Nathan; Jarvis, Thomas; Paseltiner, Daniel; Lannert, Courtney
2016-05-01
We have proposed using NASA's Cold Atom Laboratory (CAL, launching to the International Space Station in 2017) to generate bubble-geometry Bose-Einstein condensates through radiofrequency dressing of an atom-chip magnetic trap. This geometry has not been truly realized terrestrially due to the perturbing influence of gravity, making it an ideal candidate for microgravity investigation aboard CAL. We report progress in the construction of a functional prototype of the orbital BEC apparatus: a compact atom-chip machine loaded by a 2D+MOT source, conventional 3D MOT, quadrupole trap, and transfer coil. We also present preliminary modeling of the dressed trap uniformity, which will crucially inform the geometric closure of the BEC shell surface as atom number, bubble radius, and bubble aspect ratio are varied. Finally, we discuss plans for experimental sequences to be run aboard CAL guided by intuition from ground-based prototype operation. JPL 1502172.
Vitreous Anorthite (CaAl2Si2O8) at High Pressure: A First-Principles Molecular Dynamics Study
NASA Astrophysics Data System (ADS)
Ghosh, D. B.; Karki, B. B.
2017-12-01
Due to the high abundance of silicates and aluminosilicates inside the earth, their corresponding melts are likely to be one of the key transport agents in the chemical and thermal evolution of our planet and therefore, have long been the subject of investigations. Experimentally, in-situ melt properties of these materials, particularly at high pressure-temperature conditions are extremely difficult to constrain and the corresponding glass phases are considered as analogs. This, however, prohibits one-to-one comparison between the properties of silicate melt and its corresponding glass. With the aim to enable such comparison, we investigate the equation of state and structural properties of CaAl2Si2O8 glass at 300 K as a function of pressure up to 160 GPa from first principles molecular dynamics simulation results. Our results show that at ambient pressure: (i) Si's remain mostly (> 95%) under tetrahedral oxygen surroundings, (ii) unlike anorthite crystal, presence of high coordination (> 4) Al's with 30% abundance, (iii) and significant presence of both non bridging (8%) and triply (17%) coordinated oxygen. In the 0-10 GPa interval, mainly topological changes occur in the Si-O (also Al-O to some extent) surroundings in the cold compressed case in comparison to smooth increase in the average bond distance and coordination in the hot compressed case. Further compression results in gradual increases in: mean coordination, proportion of O-triclusters and increasing appearance of tetrahedral oxgyens, with Si-O (Al-O) reaching 6 (6.5) and O-T > 3 (T=Si and Al) at the highest compression. Due to the absence of kinetic barrier, the hot compressed glasses consistently produce greater densities and higher coordination numbers than the cold compression cases. Decompressed glasses show irreversible compaction along with retention of high coordination species when decompressed from > 10 GPa and degree of irreversibility depends on the peak pressure of decompression. These structural details suggest that the pressure response of the cold compressed glasses are not only inherently different in the 0 - 10 GPa interval, the density and the average coordination are consistently lower than the hot compressed glasses. Hot-compressed glasses may therefore be the better analog in the study of high-pressure silicate melts.
2008-01-01
Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri-ulcer injection of granulocyte-macrophage colony-stimulating factor, short-stretch bandages, single-layer non-elastic system, skin grafting, superficial vein surgery, systemic mesoglycan, therapeutic ultrasound, self-help (advice to elevate leg, advice to keep leg active, advice to modify diet, advice to stop smoking, advice to reduce weight), and topical treatments (antimicrobial agents, autologous platelet lysate, calcitonin gene-related peptide plus vasoactive intestinal polypeptide, freeze-dried keratinocyte lysate, mesoglycan, negative-pressure recombinant keratinocyte growth factor, platelet-derived growth factor). PMID:19445798
THE LAUNCHING OF COLD CLOUDS BY GALAXY OUTFLOWS. II. THE ROLE OF THERMAL CONDUCTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brüggen, Marcus; Scannapieco, Evan
2016-05-01
We explore the impact of electron thermal conduction on the evolution of radiatively cooled cold clouds embedded in flows of hot and fast material as it occurs in outflowing galaxies. Performing a parameter study of three-dimensional adaptive mesh refinement hydrodynamical simulations, we show that electron thermal conduction causes cold clouds to evaporate, but it can also extend their lifetimes by compressing them into dense filaments. We distinguish between low column-density clouds, which are disrupted on very short times, and high-column density clouds with much longer disruption times that are set by a balance between impinging thermal energy and evaporation. Wemore » provide fits to the cloud lifetimes and velocities that can be used in galaxy-scale simulations of outflows in which the evolution of individual clouds cannot be modeled with the required resolution. Moreover, we show that the clouds are only accelerated to a small fraction of the ambient velocity because compression by evaporation causes the clouds to present a small cross-section to the ambient flow. This means that either magnetic fields must suppress thermal conduction, or that the cold clouds observed in galaxy outflows are not formed of cold material carried out from the galaxy.« less
Exploratory Investigation into the Durability of Beneficial Cold Worked Fastener Hole in Aluminum
NASA Technical Reports Server (NTRS)
Johnson, W. S.; Clark, David A.
1999-01-01
Cold working fastener holes in aluminum alloys is a widely used technique in the aerospace industry for improving the fatigue performance of structures. A compressive tangential stress introduced in the material during the cold working of the hole reduces the natural tendency of the material to crack at the holes under cyclic tensile loading. It is a lucrative technique for the aerospace industry in that it provides an increase in performance without any weight cost.
Honey as a topical treatment for wounds.
Jull, Andrew B; Rodgers, Anthony; Walker, Natalie
2008-10-08
Honey is a viscous, supersaturated sugar solution derived from nectar gathered and modified by the honeybee, Apis mellifera. Honey has been used since ancient times as a remedy in wound care. Evidence from animal studies and some trials has suggested honey may accelerate wound healing. The objective was to determine whether honey increases the rate of healing in acute wounds (burns, lacerations and other traumatic wounds) and chronic wounds (venous ulcers, arterial ulcers, diabetic ulcers, pressure ulcers, infected surgical wounds). We searched the Cochrane Wounds Group Specialised Register (May 2008), CENTRAL (May 2008) and several other electronic databases (May 2008). Bibliographies were searched and manufacturers of dressing products were contacted for unpublished trials. Randomised and quasi randomised trials that evaluated honey as a treatment for any sort of acute or chronic wound were sought. There was no restriction in terms of source, date of publication or language. Wound healing was the primary endpoint. Data from eligible trials were extracted and summarised using a data extraction sheet by one author and independently verified by a second author. 19 trials (n=2554) were identified that met the inclusion criteria. In acute wounds, three trials evaluated the effect of honey in acute lacerations, abrasions or minor surgical wounds and nine trials evaluated the effect the honey in burns. In chronic wounds two trials evaluated the effect of honey in venous leg ulcers and one trial in pressure ulcers, infected post-operative wounds, and Fournier's gangrene respectively. Two trials recruited people with mixed groups of chronic or acute wounds. The poor quality of most of the trial reports means the results should be interpreted with caution, except in venous leg ulcers. In acute wounds, honey may reduce time to healing compared with some conventional dressings in partial thickness burns (WMD -4.68 days, 95%CI -4.28 to -5.09 days). All the included burns trials have originated from a single centre, which may have impact on replicability. In chronic wounds, honey in addition to compression bandaging does not significantly increase healing in venous leg ulcers (RR 1.15, 95%CI 0.96 to 1.38). There is insufficient evidence to determine the effect of honey compared with other treatments for burns or in other acute or chronic wound types. Honey may improve healing times in mild to moderate superficial and partial thickness burns compared with some conventional dressings. Honey dressings as an adjuvant to compression do not significantly increase leg ulcer healing at 12 weeks. There is insufficient evidence to guide clinical practice in other areas.
Lightweight, Self-Deployable Wheels
NASA Technical Reports Server (NTRS)
Chmielewski, Artur; Sokolowski, Witold; Rand, Peter
2003-01-01
Ultra-lightweight, self-deployable wheels made of polymer foams have been demonstrated. These wheels are an addition to the roster of cold hibernated elastic memory (CHEM) structural applications. Intended originally for use on nanorovers (very small planetary-exploration robotic vehicles), CHEM wheels could also be used for many commercial applications, such as in toys. The CHEM concept was reported in "Cold Hibernated Elastic Memory (CHEM) Expandable Structures" (NPO-20394), NASA Tech Briefs, Vol. 23, No. 2 (February 1999), page 56. To recapitulate: A CHEM structure is fabricated from a shape-memory polymer (SMP) foam. The structure is compressed to a very small volume while in its rubbery state above its glass-transition temperature (Tg). Once compressed, the structure can be cooled below Tg to its glassy state. As long as the temperature remains
Wong, I K Y; Andriessen, A; Charles, H E; Thompson, D; Lee, D T F; So, W K W; Abel, M
2012-01-01
In Hong Kong, at the time of the study, compression treatment was not considered usual care for venous leg ulcer patients. This randomized controlled trial compared quality of life (QOL) aspects in venous leg ulcer patients of over 55-years of age, of short-stretch compression (SSB), four-layer compression bandaging (4LB) and usual care (UC) (moist wound healing dressing, no compression). Study period was 24-weeks, the primary outcome was the patient functional status, disease-specific and generic health-related QOL measures and ulcer healing rates, comparing week 1 vs. week 24 (end) results. Assessments included photogrammetry, Brief Pain Inventory, SF-12 Health Survey, Charing Cross Venous Ulcer Questionnaire and Frenchay Activity Index. Data analysis was performed using, where appropriate; Kaplan Meier and log rank chi-square and the repeated measures analysis of variance test. A total of 321 patients participated in the study, 45 (14%) withdrew for various reasons. Compression bandaging in both groups significantly reduced pain (P < 0.0001) and improved functional status and QOL. Healing rate at 24 weeks for both compression groups was significant (P < 0.001); for SSB this was 72.0% (77/107) vs. 67.3% in the 4LB group (72/107) and 29.0% (31/107) with usual care. The reduction in ulcer area from weeks 12 to 24 was significant only for SSB (P < 0.047). Compression was shown to be feasible for elderly community care patients in Hong Kong and is currently implemented as part of standard venous leg ulcer treatment. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.
NASA Astrophysics Data System (ADS)
Clenci, Adrian; Niculescu, Rodica; Iorga-Simǎn, Victor; Tricǎ, Alina; Danlos, Amélie
2017-02-01
The use of biodiesel fuel in compression ignition engines has the potential to reduce CO2, which can lead to a reduction in global warming and environmental hazards. Biodiesel is an attractive fuel, as it is made from renewable resources. A major drawback associated with the use of biodiesel, however, is its poor cold flow properties, which have a direct influence on the cold starting performance of the engine. This paper is a consequence of a study on assessing the cold-starting performance of a compression ignition engine fueled with different blends of fossil diesel fuel and biodiesel. Through experimental investigations, it was found that the engine starting at -20°C was no longer possible in the case of using B50 (50% diesel + 50% biofuel made from sunflower oil). In order to "force" the engine starting in this particular situation, Di-Ethyl-Ether (DEE) was injected into the intake manifold. DEE being a highly flammable substance, the result was a sudden and explosive engine starting, the peak pressure in the monitored cylinder in the first successful engine cycle being almost twice the one which is usually considered as normal. Thus, to explain the observed phenomena, we launched this work relying on the analysis of the in-cylinder instantaneous pressure evolution, which was acquired during cranking, stabilizing and idling phases. Moreover, since the cause of the sudden and explosive engine starting was the DEE, by using a CFD approach, we also obtained results regarding the inter-cylinder distribution of the injected DEE.
Effect of fast freeze-thaw cycles on mechanical properties of ordinary-air-entrained concrete.
Shang, Huai-shuai; Cao, Wei-qun; Wang, Bin
2014-01-01
Freezing-thawing resistance is a very significant characteristic for concrete in severe environment (such as cold region with the lowest temperature below 0°C). In this study, ordinary-air-entrained (O-A-E) concrete was produced in a laboratory environment; the compressive strength, cubic compressive strength of C50, C40, C30, C25, and C20 ordinary-air-entrained concrete, tensile strength, and cleavage strength of C30 ordinary-air-entrained concrete were measured after fast freeze-thaw cycles. The effects of fast freeze-thaw cycles on the mechanical properties (compressive strength and cleavage strength) of ordinary-air-entrained concrete materials are investigated on the basis of the experimental results. And the concise mathematical formula between mechanical behavior and number of fast freeze-thaw cycles was established. The experiment results can be used as a reference in design, maintenance, and life prediction of ordinary-air-entrained concrete structure (such as dam, offshore platform, etc.) in cold regions.
Effective Cross Section of Cold Formed Steel Column Under Axial Compression
NASA Astrophysics Data System (ADS)
Manikandan, P.; Pradeep, T.
2018-06-01
The compressive resistance of cold-formed steel (CFS) section may be governed by local, distortional or overall buckling and any apparent interaction between these modes. A new inventive stiffened CFS section is elected in this study, selected cross sections geometries and lengths are chosen such that all the types of buckling modes are met with. Buckling plot is plotted using linear elastic buckling analysis software (CUFSM). Using the test results obtained in the literature, the developed finite element model is calibrated and furthers a total of 126 parametric study is conducted such as a consequence of dimensions and the length of the cross section, thickness and yield stress. The FEA included relevant material and geometric imperfections. All the columns are analyzed under pin end conditions with axial compression. The analysis results demonstrate that the DSM equations generally assess the strength of stiffened section conservatively. Modifications to the DSM equations are recommended to evaluate the strength of stiffened section more precisely.
Effect of Fast Freeze-Thaw Cycles on Mechanical Properties of Ordinary-Air-Entrained Concrete
Shang, Huai-shuai; Cao, Wei-qun; Wang, Bin
2014-01-01
Freezing-thawing resistance is a very significant characteristic for concrete in severe environment (such as cold region with the lowest temperature below 0°C). In this study, ordinary-air-entrained (O-A-E) concrete was produced in a laboratory environment; the compressive strength, cubic compressive strength of C50, C40, C30, C25, and C20 ordinary-air-entrained concrete, tensile strength, and cleavage strength of C30 ordinary-air-entrained concrete were measured after fast freeze-thaw cycles. The effects of fast freeze-thaw cycles on the mechanical properties (compressive strength and cleavage strength) of ordinary-air-entrained concrete materials are investigated on the basis of the experimental results. And the concise mathematical formula between mechanical behavior and number of fast freeze-thaw cycles was established. The experiment results can be used as a reference in design, maintenance, and life prediction of ordinary-air-entrained concrete structure (such as dam, offshore platform, etc.) in cold regions. PMID:24895671
DOE Office of Scientific and Technical Information (OSTI.GOV)
Entin, V. M.; Yakshina, E. A.; Tretyakov, D. B.
2013-05-15
The spectra of the three-photon laser excitation 5S{sub 1/2} {yields} 5P{sub 3/2} {yields} 6S{sub 1/2}nP of cold Rb Rydberg atoms in an operating magneto-optical trap based on continuous single-frequency lasers at each stage are studied. These spectra contain two partly overlapping peaks of different amplitudes, which correspond to coherent three-photon excitation and incoherent three-step excitation due to the presence of two different ways of excitation through the dressed states of intermediate levels. A four-level theoretical model based on optical Bloch equations is developed to analyze these spectra. Good agreement between the experimental and calculated data is achieved by introducing additionalmore » decay of optical coherence induced by a finite laser line width and other broadening sources (stray electromagnetic fields, residual Doppler broadening, interatomic interactions) into the model.« less
Use of ultraportable vacuum therapy systems in the treatment of venous leg ulcer.
Cuomo, Roberto; Nisi, Giuseppe; Grimaldi, Luca; Brandi, Cesare; D'Aniello, Carlo
2017-10-23
The high incidence of venous leg ulcers and the difficult to give a complete healing involves in an increase of costs for National Health System. Main therapies to obtain a fast healing are compressive bandages, treatment of abnormal venous flow and in-situ-strategies of wound care. Negative pressure therapy does not conventionally used, because these systems not allow the use of compression bandages. Recently the development of ultraportable devices has improved the compliance and the results. Ten patients with venous chronic ulcer on the lower extremities were recruited for this study: all patients had venous leg ulcers from at least one year. We treated the patients with autologous partial thickness skin graft and subsequently we applied NANOVA device included in compressive bandage. We used NANOVA for fourteen days and after we made traditional medications. We submitted a questionnaire to evaluate the impact of dressing and NANOVA device in the quality of life of patients. The device contributed to the formation of granulation tissue and increased the success rate of autologous skin graft without limiting mobility of patient. In addition to this, we have been able to perform compression bandages thanks to small size of this device. Eight ulcers healed within 90 days of medication. We believe that ultraportable negative pressure systems are useful devices for treatment of venous leg ulcers because them allows to realize a compressive bandage without mobility limitations.
Alterations in resting oxygen consumption in women exposed to 10 days of cold air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armstrong, D.W.; Thomas, J.R.
1991-03-11
Repeated exposure to cold air reduces the metabolic response to cold air exposure in man. The purpose of this investigation was to measure the change in resting metabolic rate (RMR) with exposure to 22C air and 4C air during a 12 day period. Four women sat in 22C air for 45 min followed by 45 min in 4C air each day for ten days. The authors measured RMR during a 45 min period in 22C air followed by 45 min in 4C air on four days. All subjects began their morning exposures on a Monday within 2 days of themore » onset of menses completing the study on a Friday, 12 days later. Subjects dressed in a T-shirt, shorts and cotton socks. During 45 min of exposure to warm air, RMR remained steady at 10% of VO{sub 2peak} on Day 1 and 10% on Day 5. RMR during exposure to warm air significantly increased to 13% of VO{sub 2peak} on Day 8 and remained elevated at 13% on Day 12. During exposure to cold air RMR peaked at 31% of CO{sub 2peak} by the 5th min on Day 1. Peak RMR on Day 5 was significantly lower. Pea RMR in the cold remained lower on Days 8 and 12. During cold exposure RMR peaked and then declined to steady-state during min 15 to 45. Steady-state RMR during cold exposure was significantly lower on Day 5, Day 7 and Day 12 when compared to the 23% of VO{sub 2peak} on Day 1. The authors found that RMR in cold air is significantly attenuated by Day 5 and remains lower through Day 12. RMR during warm air exposure is elevated 3% by Day 8 after five (5) days of repeated cold exposure followed by two (2) days without exposure to cold air, and RMR remains elevated on Day 12.« less
1980-11-01
acket (E/AP) and to assess performance and physiological effects of t he ration at two different ca loric levels. During a f ive-day exercise in a...PACKET FIELD FEEDING RAT IONS DIET(S) PHYSIOLOG ICAL EMERGENCY RATIONS COMPRESSED FOODS TESTS FREEZE DRIED FOODS COLD WEATH ER PERFORMANCE...cold-weather climate, one group of Marines was issued the standard C ration (3550 kca l) while half of a second group were issued one E/AP per day
NASA Astrophysics Data System (ADS)
Zhang, Yanqiu; Jiang, Shuyong; Hu, Li; Zhao, Yanan; Sun, Dong
2017-10-01
The behavior of primary static recrystallization (SRX) in a NiTiFe shape memory alloy (SMA) subjected to cold canning compression was investigated using the coupling crystal plasticity finite element method (CPFEM) with the cellular automaton (CA) method, where the distribution of the dislocation density and the deformed grain topology quantified by CPFEM were used as the input for the subsequent SRX simulation performed using the CA method. The simulation results were confirmed by the experimental ones in terms of microstructures, average grain size and recrystallization fraction, which indicates that the proposed coupling method is well able to describe the SRX behavior of the NiTiFe SMA. The results show that the dislocation density exhibits an inhomogeneous distribution in the deformed sample and the recrystallization nuclei mainly concentrate on zones where the dislocation density is relatively higher. An increase in the compressive deformation degree leads to an increase in nucleation rate and a decrease in grain boundary spaces in the compression direction, which reduces the growth spaces for the SRX nuclei and impedes their further growth. In addition, both the mechanisms of local grain refinement in the incomplete SRX and the influence of compressive deformation degree on the grain size of SRX were vividly illustrated by the corresponding physical models.
Caprini, J.A.; Partsch, H.; Simman, R.
2013-01-01
Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636
Tawfick, W; Sultan, S
2009-07-01
Topical wound oxygen (TWO(2)) may help wound healing in the management of refractory venous ulcers (RVU). The aim of this study was to measure the effect of TWO(2) on wound healing using the primary end-point of the proportion of ulcers healed at 12 weeks. Secondary end-points were time to full healing, percentage of reduction in ulcer size, pain reduction, recurrence rates and Quality-Adjusted Time Spent Without Symptoms of disease and Toxicity of Treatment (Q-TWiST). A parallel observational comparative study. Patients with CEAP C(6,s) RVU, assessed by duplex ultrasonography, were managed with either TWO(2) (n=46) or conventional compression dressings (CCD) (n=37) for 12 weeks or till full healing. Patients were followed up at 3 monthly intervals. At 12 weeks, 80% of TWO(2) managed ulcers were completely healed, compared to 35% of CCD ulcers (p<0.0001). Median time to full healing was 45 days in TWO(2) patients and 182 days in CCD patients (p<0.0001). The pain score threshold in TWO(2) managed patients improved from 8 to 3 by 13 days. After 12-month follow-up, 5 of the 13 healed CCD ulcers showed signs of recurrence compared to none of the 37 TWO(2) healed ulcers. TWO(2) patients experienced a significantly improved Q-TWiST. TWO(2) reduces recurrence rates, alleviates pain and improves the Q-TWiST. We believe it is a valuable tool in the armamentarium of management of RVU.
Miguel, Giulianna Z; Faria, Marcelo H; Roça, Roberto O; Santos, Carolina T; Suman, Surendranath P; Faitarone, Ana B G; Delbem, Nara L C; Girao, Lucio V C; Homem, Juliana M; Barbosa, Erika K; Su, Leticia S; Resende, Flavio D; Siqueira, Gustavo R; Moreira, Aline D; Savian, Taciana V
2014-02-01
The objective was to examine the effects of immunocastration on carcass traits and meat quality of Nellore and Nellore×Aberdeen Angus male animals finished in feedlot. Surgically castrated, immunocastrated, and intact animals were finished in feedlot for 90 days. The animals were harvested, and carcass traits were evaluated. Carcasses were chilled, and one 2.5-cm steak was fabricated from Longissimus thoracis muscle. The steaks were individually vacuum packaged and frozen at -18 °C. Frozen steaks were thawed, and pH, instrumental color, cooking loss, and shear force were determined. Immunocastrated animals demonstrated greater (P<0.05) hot dressing percentage and cold dressing percentage than their surgically castrated counterparts. Furthermore, steaks from immunocastrated and surgically castrated animals exhibited greater redness (P<0.05) and lower darkness (P<0.05) than steaks from intact animals, indicating possible advantage in retailing. The results suggested that immunocastration may be utilized to improve carcass traits and beef color in feedlot-finished Nellore and Nellore×Aberdeen Angus males. © 2013.
Planar temperature measurement in compressible flows using laser-induced iodine fluorescence
NASA Technical Reports Server (NTRS)
Hartfield, Roy J., Jr.; Hollo, Steven D.; Mcdaniel, James C.
1991-01-01
A laser-induced iodine fluorescence technique that is suitable for the planar measurement of temperature in cold nonreacting compressible air flows is investigated analytically and demonstrated in a known flow field. The technique is based on the temperature dependence of the broadband fluorescence from iodine excited by the 514-nm line of an argon-ion laser. Temperatures ranging from 165 to 245 K were measured in the calibration flow field. This technique makes complete, spatially resolved surveys of temperature practical in highly three-dimensional, low-temperature compressible flows.
2011-01-01
Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2011 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 101 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri-ulcer injection of granulocyte-macrophage colony-stimulating factor, self-help (advice to elevate leg, to keep leg active, to modify diet, to stop smoking, to reduce weight), short-stretch bandages, single-layer non-elastic system, skin grafting, superficial vein surgery, systemic mesoglycan, therapeutic ultrasound, and topical treatments (antimicrobial agents, autologous platelet lysate, calcitonin gene-related peptide plus vasoactive intestinal polypeptide, freeze-dried keratinocyte lysate, mesoglycan, negative pressure, recombinant keratinocyte growth factor, platelet-derived growth factor). PMID:22189344
Gümüş, Kenan; Özlü, Zeynep Karaman
2017-10-01
This study was planned to investigate the effect of a mixture of beeswax, olive oil and A. Tinctoria (L.) Tausch on burn wounds to determine the impact on burn healing, pain during dressing changes and duration of hospital stay. The study was conducted between May 2014 and August 2015 in the Burn Unit of Ataturk University Research Hospital. The sample of this experimental study consisted of 64 patients (31 experimental group and 33 control group) who met its inclusion criteria. While the specially prepared dressing material was applied to the experimental group, the control group was administered the clinic's routine dressing. The injuries were photographed before each dressing. Each picture was uploaded to a computer for measurement with ImageJ software. Numbers, percentages, chi square, Independent samples t-test and Mann-Whitney U tests were used to assess the data. The patients in the experimental and control groups had similar descriptive characteristics and burn injury features (p>0.05). The average age of the patients in the control group was 5.52±0.64years, and 6.68±1.09years in the experimental group. The majority of the patients were male (control: 54.5%, experimental: 58.1%). Boiling liquids were the most common cause of both groups' burns (control: 93.9%, experiment: 83.9%). The most common first aid practice used was the application of cold water (control: 75.0%, experimental: 43.6%). The epithelization initiation time average of the experimental group patients (3.00±0.85days) was found to be earlier than that of the control group patients (6.90±1.77days), and this difference was statistically significant (p<0.05). The mean pain scores experienced by the patients in the experimental group during dressing (8.12±1.38) were determined to be lower than those of the control group (9.39±1.05), and this difference was statistically significant (p<0.05). It was also found that mean hospitalization durations of the patients in the experimental group (8.22±3.05) were shorter than those of the control group (14.42±7.79), and this difference was also found to be statistically significant (p<0.05). When a beeswax, olive oil and A. tinctoria (L.) Tausch mixture was applied to second degree burns, this accelerated epithelization, reduced the pain experienced during dressing changes and shortened the hospital stay durations of the patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ali, Mujtaba M; Loretz, Lorraine; Shea, Art; Poorvu, Eli; Robinson, William P; Schanzer, Andres; Messina, Louis M; Baril, Donald T
2013-11-01
Despite advances in the treatment of peripheral arterial disease, a significant number of patients ultimately require major amputations. Traditionally, postoperative management of a below-knee amputation involves soft compressive dressings to allow for complete stump healing before initial prosthesis fitting. This technique is associated with a prolonged period of limited mobility, placing patients at risk for deconditioning or fall with a risk of injury to the stump. In contrast, immediate postoperative prosthesis (IPOP) placement allows patients to begin ambulation and rehabilitation on postoperative day 1, which may be of significant physiologic and psychological benefit. The purpose of this study is to compare the outcomes of patients undergoing IPOP placement to those of a historical control group managed with traditional soft compressive dressing placement. Medical records of all consecutive below-knee amputation patients who underwent IPOP (IPOP group; 37 patients, 2007-2010) and all patients who underwent traditional soft compressive dressing placement and were IPOP candidates (non-IPOP group; 35 patients, 2006-2007) were retrospectively reviewed. Patient comorbidities and preoperative ambulation status were compared between the IPOP and the non-IPOP groups. Primary outcomes evaluated included perioperative systemic complications, wound complications, need for surgical revision, and the time until placement of a definitive prosthesis. Data were analyzed using the chi-squared and Student's t-test. Preoperative comorbidities and patient characteristics of the 2 groups were similar, although the IPOP group was younger (61.5 vs. 69.0 years; P=0.01). Immediate perioperative systemic complication rates were not significantly different between the 2 groups (IPOP 29.7% vs. non-IPOP 31.4%; P=0.876). Postoperative wound complication rates were as follows: wound infection (IPOP 18.9% vs. non-IPOP 25.0%; P=0.555), wound dehiscence (IPOP 29.7% vs. non-IPOP 25.0%; P=0.673), and skin breakdown separate from the incision (IPOP 18.9% vs. non-IPOP 3.6%; P=0.062). Patients in the IPOP group trended towards fewer postoperative falls (IPOP 10.8% vs. non-IPOP 21.4%; P=0.240). The need for revision was significantly greater in the non-IPOP group (IPOP 5.4% vs. non-IPOP 27.6%; P=0.013). The time from surgery to placement of the preparatory prosthesis was 51 days in the IPOP group. Patients undergoing IPOP have similar perioperative systemic and wound complication rates compared to those patients undergoing conventional below-knee amputation, but are less likely to require surgical revision. The use of IPOP allows for early ambulation and rehabilitation, which may be of psychological benefit and may decrease the sequelae of prolonged immobilization. IPOP application should be considered for all appropriate candidates requiring below-knee amputation. Copyright © 2013 Elsevier Inc. All rights reserved.
Limited Range Sesame EOS for Ta
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greeff, Carl William; Crockett, Scott; Rudin, Sven Peter
2017-03-30
A new Sesame EOS table for Ta has been released for testing. It is a limited range table covering T ≤ 26, 000 K and ρ ≤ 37.53 g/cc. The EOS is based on earlier analysis using DFT phonon calculations to infer the cold pressure from the Hugoniot. The cold curve has been extended into compression using new DFT calculations. The present EOS covers expansion into the gas phase. It is a multi-phase EOS with distinct liquid and solid phases. A cold shear modulus table (431) is included. This is based on an analytic interpolation of DFT calculations.
On the possibility of generation of cold and additional electric energy at thermal power stations
NASA Astrophysics Data System (ADS)
Klimenko, A. V.; Agababov, V. S.; Borisova, P. N.
2017-06-01
A layout of a cogeneration plant for centralized supply of the users with electricity and cold (ECCG plant) is presented. The basic components of the plant are an expander-generator unit (EGU) and a vapor-compression thermotransformer (VCTT). At the natural-gas-pressure-reducing stations, viz., gas-distribution stations and gas-control units, the plant is connected in parallel to a throttler and replaces the latter completely or partially. The plant operates using only the energy of the natural gas flow without burning the gas; therefore, it can be classified as a fuelless installation. The authors compare the thermodynamic efficiencies of a centralized cold supply system based on the proposed plant integrated into the thermal power station scheme and a decentralized cold supply system in which the cold is generated by electrically driven vapor-compression thermotransformers installed on the user's premises. To perform comparative analysis, the exergy efficiency was taken as the criterion since in one of the systems under investigation the electricity and the cold are generated, which are energies of different kinds. It is shown that the thermodynamic efficiency of the power supply using the proposed plant proves to be higher within the entire range of the parameters under consideration. The article presents the results of investigating the impact of the gas heating temperature upstream from the expander on the electric power of the plant, its total cooling capacity, and the cooling capacities of the heat exchangers installed downstream from the EGU and the evaporator of the VCTT. The results of calculations are discussed that show that the cold generated at the gas-control unit of a powerful thermal power station can be used for the centralized supply of the cold to the ventilation and conditioning systems of both the buildings of the power station and the neighboring dwelling houses, schools, and public facilities during the summer season.
NASA Technical Reports Server (NTRS)
Rumsey, C. L.
2009-01-01
The ability of kappa-omega models to predict compressible turbulent skin friction in hypersonic boundary layers is investigated. Although uncorrected two-equation models can agree well with correlations for hot-wall cases, they tend to perform progressively worse - particularly for cold walls - as the Mach number is increased in the hypersonic regime. Simple algebraic models such as Baldwin-Lomax perform better compared to experiments and correlations in these circumstances. Many of the compressibility corrections described in the literature are summarized here. These include corrections that have only a small influence for kappa-omega models, or that apply only in specific circumstances. The most widely-used general corrections were designed for use with jet or mixing-layer free shear flows. A less well-known dilatation-dissipation correction intended for boundary layer flows is also tested, and is shown to agree reasonably well with the Baldwin-Lomax model at cold-wall conditions. It exhibits a less dramatic influence than the free shear type of correction. There is clearly a need for improved understanding and better overall physical modeling for turbulence models applied to hypersonic boundary layer flows.
Quality control in chronic wound management: the role of local povidone-iodine (Betadine) therapy.
Daróczy, Judit
2006-01-01
The treatment of venous leg ulcers is often inadequate, because of incorrect diagnosis, overuse of systemic antibiotics and inadequate use of compression therapy. Stasis dermatitis related to chronic venous insufficiency accompanied by infected superficial ulcers must be differentiated from erysipelas, cellulitis and contact eczema. To assess the effectiveness of (1) topical povidone-iodine with and (2) without compression bandages, (3) to compare the efficacy of systemic antibiotics and topical antimicrobial agents to prevent the progression of superficial skin ulcers. 63 patients presenting ulcerated stasis dermatitis due to deep venous refluxes were included in the study. The clinical stage of all patients was homogeneous determined by clinical, aetiological, anatomical and pathological classification. They were examined by taking a bacteriological swab from their ulcer area. Compression bandages were used in a total of 42 patients. Twenty-one patients with superficial infected (Staphylococcus aureus) ulcers were treated locally with povidone-iodine (Betadine), and 21 patients were treated with systemic antibiotics (amoxicillin). Twenty-one patients were treated locally with Betadine but did not use compression. The end point was the time of ulcus healing. The healing process of the ulcers was related to the impact of bacterial colonization and clinical signs of infection. Compression increases the ulcer healing rate compared with no compression. Using the same local povidone-iodine (Betadine) treatment with compression bandages is more effective (82%) for ulcus healing than without compression therapy (62%). The healing rate of ulcers treated with systemic antibiotics was not significantly better (85%) than that of the Betadine group. Using systemic antibiotics, the relapse rate of superficial bacterial infections (impetigo, folliculitis) was significantly higher (32%) than in patients with local disinfection (11%). Compression is essential in the mobilization of the interstitial lymphatic fluid from the region of stasis dermatitis. Topical disinfection and appropriate wound dressings are important to prevent wound infection. Systemic antibiotics are necessary only in systemic infections (fever, lymphangitis, lymphadenopathy, erysipelas).
... over the place, including in grassy fields, along lakes and streams, and in forests. There are adult ... some calamine lotion or a cold compress (like ice wrapped in a clean towel) on the area. ...
Bouzigon, Romain; Grappe, Frederic; Ravier, Gilles; Dugue, Benoit
2016-10-01
Cold therapy is commonly used as a method to relieve pain and inflammation. This review focuses primarily on two methods of cold therapy that have received recent attention: whole-body cryotherapy and partial-body cryotherapy. These methods are used to induce physiological and psychological benefits in humans in the context of medicine, health and sports. The subjects experiencing cryotherapy are dressed in minimal clothing and are exposed to very cold air (at -110°C or less) for 1-4min. Despite the increasing scientific interest in these methods, there is a lack of information about the technologies used. Moreover, there is no existing reference concerning exposure protocols and the relationship between temperature, duration, number of repetitions and the treatments' desired effects. The aim of this review is to compare whole- and partial-body cryotherapy effects (especially on skin temperature) and to classify the protocols for exposure according to the desired effects. This review emphasises 1) the lack of information concerning the actual temperatures inside the cabin or chamber during exposure and 2) the heterogeneity among the exposure protocols that have been reported in the scientific literature. This review will be valuable and relevant to health professionals endeavouring to optimize the cold treatments offered to patients and producers of cryotherapy apparatus striving to create more efficient devices that meet market requirements. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chapman, B; Scurrah, K J; Ross, T
2010-05-01
A survey of 12 Australian manufacturers indicated that mild-tasting acids and preservatives are used to partially replace acetic acid in cold-filled acid dressings and sauces. In contrast to traditional ambient temperature distribution practices, some manufacturers indicated that they supply the food service sector with cold-filled acid products prechilled for incorporation into ready-to-eat foods. The Comité des Industries des Mayonnaises et Sauces Condimentaires de la Communauté Economique Européenne (CIMSCEE) Code, a formulation guideline used by the industry to predict the safety of cold-filled acid formulations with respect to Salmonella enterica and Escherichia coli, does not extend to the use of acids and preservatives other than acetic acid nor does it consider the effects of chill distribution. We found insufficient data in the published literature to comprehensively model the response of S. enterica and E. coli to all of the predictor variables (i.e., pH, acetic acid, NaCl, sugars, other acids, preservatives, and storage temperature) of relevance for contemporary cold-filled acid products in Australia. In particular, we noted a lack of inactivation data for S. enterica at aqueous-phase NaCl concentrations of >3% (wt/wt). However, our simple models clearly identified pH and 1/absolute temperature of storage as the most important variables generally determining inactivation. To develop robust models to predict the effect of contemporary formulation and storage variables on product safety, additional empirical data are required. Until such models are available, our results support challenge testing of cold-filled acid products to ascertain their safety, as suggested by the CIMSCEE, but suggest consideration of challenging with both E. coli and S. enterica at incubation temperatures relevant to intended product distribution temperatures.
Aramwit, Pornanong; Ratanavaraporn, Juthamas; Siritientong, Tippawan
2015-08-01
This study aimed to use glycerin to improve physical and wound adhesion properties of a wound dressing made of silk sericin and polyvinyl alcohol (PVA). Glycerin of a natural-derived plasticizer was used to modify the properties of silk sericin/PVA scaffolds. Various concentrations of glycerin were mixed with silk sericin and PVA and then fabricated into the scaffolds by a freeze-drying technique. The control study was performed to examine the properties of the silk sericin/PVA scaffolds with and without glycerin. Physical, mechanical, wound adhesion properties, the release profile of silk sericin, and in vivo safety of the silk sericin/PVA scaffolds with and without glycerin were investigated. The silk sericin/PVA scaffolds with glycerin exhibited more homogenous structure, less compressive modulus, higher Young modulus and elongation percentage, and a higher degree of crosslinking compared with the scaffold without glycerin. The silk sericin/PVA scaffold with 2% wt/vol glycerin showed more controlled release of silk sericin than the other scaffolds. The sustained release of silk sericin from the scaffold with glycerin would be advantageous for long-term healing of wounds. The silk sericin/PVA scaffold with 2% (wt/vol) glycerin was less adhesive to the wound compared with the scaffold without glycerin. Furthermore, the implantation of silk sericin/PVA scaffolds with 2% (wt/vol) glycerin did not cause any irritation to the tissue. The silk sericin/PVA scaffolds with glycerin were introduced as a biocompatible, more flexible, and less adhesive wound dressing than the scaffold without glycerin.
Chailler, Myrianne; Ellis, Jacqueline; Stolarik, Anne; Woodend, Kirsten
2010-01-01
Coughing has been identified as the most painful experience post cardiac surgery. Participants (n = 32), in a randomized crossover trial, applied a frozen gel pack to their sternal incision dressing before performing deep breathing and coughing (DB & C) exercises. Pain scores from 0 to 10 at rest were compared with pain scores post DB & C with and without the gel pack. Participants were also asked to describe their sensations with the frozen gel pack, as well as their preferences for gel pack application. The repeated measures analysis of variance revealed a significant reduction in pain scores between pre- and post-application of the gel pack (F = 28.69, p < .001). There were 22 (69%) participants who preferred the application of the gel pack compared with no gel pack. All 32 (100%) participants would reapply the gel pack in the future. This study demonstrates that cold therapy can be used to manage sternal incisional pain when DB & C.
Cation dynamics of molecular Hydrogen in the presence of a strong laser field, preliminary results
NASA Astrophysics Data System (ADS)
Gatton, A.; Champenois, E.; Larsen, K.; Shivaram, N.; Bakhti, S.; Iskander, W.; Sievert, T.; Reedy, D.; Weller, M.; Williams, J. B.; Landers, A.; Weber, Th.
2017-04-01
We present preliminary results from a new 2-color laser+synchrotron Cold Target Recoil Ion Momentum Spectrometer (COLTRIMS) experiment in which we overlap a pulsed laser (1030 nm , 12 ps , 5 *1011 W / cm2) with light from beamline 10 . 0 . 1 (18 . 56 eV , 80 ps , 50 meV resolution) at the Advanced Light Source at Lawrence Berkeley National Lab. The data (absent the laser) shows asymmetric proton emission in the fragmenting hydrogen cation due to the retro-action of the photoelectron Coulomb potential, as reported recently by Waitz et al.. Preliminary analysis hints that this effect exists and may even be enhanced in the laser dressed states of the dissociating cation. Of even more interest, preliminary analysis hints at the signature of light induced conical intersections in the dissociation of the laser dressed hydrogen cations, as recently reported by Natan et al.. This research used the Advanced Light Source and was supported by DOE-BES under contract No. DE-AC02-05CH11231 and DE-FG02-86ER13491, the ALS Doctoral Fellowship in Residence, and the DFG and DAAD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vauzour, B.; Laboratoire d'Optique Appliquée, ENSTA-CNRS-Ecole Polytechnique, UMR 7639, 91761 Palaiseau; Debayle, A.
2014-03-15
We present results on laser-driven relativistic electron beam propagation through aluminum samples, which are either solid and cold or compressed and heated by laser-induced shock. A full numerical description of fast electron generation and transport is found to reproduce the experimental absolute K{sub α} yield and spot size measurements for varying target thicknesses, and to sequentially quantify the collisional and resistive electron stopping powers. The results demonstrate that both stopping mechanisms are enhanced in compressed Al samples and are attributed to the increase in the medium density and resistivity, respectively. For the achieved time- and space-averaged electronic current density, 〈j{submore » h}〉∼8×10{sup 10} A/cm{sup 2} in the samples, the collisional and resistive stopping powers in warm and compressed Al are estimated to be 1.5 keV/μm and 0.8 keV/μm, respectively. By contrast, for cold and solid Al, the corresponding estimated values are 1.1 keV/μm and 0.6 keV/μm. Prospective numerical simulations involving higher j{sub h} show that the resistive stopping power can reach the same level as the collisional one. In addition to the effects of compression, the effect of the transient behavior of the resistivity of Al during relativistic electron beam transport becomes progressively more dominant, and for a significantly high current density, j{sub h}∼10{sup 12} A/cm{sup 2}, cancels the difference in the electron resistive stopping power (or the total stopping power in units of areal density) between solid and compressed samples. Analytical calculations extend the analysis up to j{sub h}=10{sup 14} A/cm{sup 2} (representative of the full-scale fast ignition scenario of inertial confinement fusion), where a very rapid transition to the Spitzer resistivity regime saturates the resistive stopping power, averaged over the electron beam duration, to values of ∼1 keV/μm.« less
Compression Strength of Sulfur Concrete Subjected to Extreme Cold
NASA Technical Reports Server (NTRS)
Grugel, Richard N.
2008-01-01
Sulfur concrete cubes were cycled between liquid nitrogen and room temperature to simulate extreme exposure conditions. Subsequent compression testing showed the strength of cycled samples to be roughly five times less than those non-cycled. Fracture surface examination showed de-bonding of the sulfur from the aggregate material in the cycled samples but not in those non-cycled. The large discrepancy found, between the samples is attributed to the relative thermal properties of the materials constituting the concrete.
Bandages and difficulty with bathing: introducing Seal-Tight.
Lindsay, Ellie
2005-06-01
Patients with compression bandages experience difficulty with bathing due to the possibility that bandages may become wet and affect the wound. Bandage and dressing changes resulting from accidental wetting also cost the NHS considerable time and money. This product focus highlights the social and psychological impact on the patient when they are unable to bathe and offers a solution to the problem. Seal-Tight is a product that has been newly placed on the drug tariff, making it widely available to all patients who wear bandages (or plaster casts). Seal-Tight enables the patient to bathe, in some cases for the first time for months or even years.
Travers, S; Dubourg, O; Ribeiro Parenti, L; Lefort, H; Albarello, S; Domanski, L
2012-12-01
First responders are sometimes confronted with external uncontrolled haemorrhage despite compression, bandages, and tourniquets. Several topical haemostatic agents were developed to try to face these situations. Their application was mainly described and studied in military environment. We report the case of a worker victim of an accident of construction site with hemorrhagic perineal trauma for whom the use of a haemostatic bandage QuikClot ACS+™ (Z-Medica) seemed to us particularly useful in prehospital setting. Copyright © 2012 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.
Hickerson, W L; Kealey, G P; Smith, D J; Thomson, P D
1994-01-01
Three institutions enrolled 38 patients who required bilateral skin graft donor sites into a safety and efficacy study of a new synthetic donor site dressing. Bilateral donor sites were randomized to receive either a new, synthetic donor site dressing or an impregnated gauze dressing. Wounds were assessed by time to healing, pain, and patient preference. Synthetic dressing wounds were treated 7.9 days compared with 10.2 days for gauze dressing wounds (p < 0.001), and synthetic dressing wounds were more completely epithelialized. Visual analogue pain analysis revealed significantly less donor site pain with synthetic dressing (2.94) versus gauze dressing (4.64) (p < 0.001). Synthetic dressing had fewer treatment-related adverse experiences than gauze dressing (2 vs 7) and was judged by recipients to be superior to gauze dressing in comfort, pain relief, cosmetic appeal, ease of ambulation, and overall acceptance.
Effects of Cold and Compression on Edema.
ERIC Educational Resources Information Center
Sloan, J. P.; And Others
1988-01-01
Investigation of ways to treat artificially induced acute inflammatory reactions in human tissue found that neither cooling or pressure alone reduced the swelling, while a combination of the two methods produced a significant reduction in swelling. (Author/CB)
Cold Spray Repair of Martensitic Stainless Steel Components
NASA Astrophysics Data System (ADS)
Faccoli, M.; Cornacchia, G.; Maestrini, D.; Marconi, G. P.; Roberti, R.
2014-12-01
The possibility of using cold spray as repair technique of martensitic stainless steel components was evaluated through laboratory investigations. An austenitic stainless steel feedstock powder was chosen, instead of soft metals powders like nickel, copper, or aluminum, used for repairing components made in light alloy or cast iron. The present study directly compares the microstructure, the residual stresses, and the micro-hardness of repairs obtained by cold spray and by TIG welding, that is commonly used as repair technique in large steel components. XRD and optical metallographic analysis of the repairs showed that cold spray offers some advantages, inducing compressive residual stresses in the repair and avoiding alterations of the interface between repair and base material. For these reasons, a heat treatment after the cold spray repair is not required to restore the base material properties, whereas a post-weld heat treatment is needed after the welding repair. Cold spray repair also exhibits a higher micro-hardness than the welding repair. In addition, the cavitation erosion resistance of a cold spray coating was investigated through ultrasonic cavitation tests, and the samples worn surfaces were observed by scanning electron microscopy.
Experiments on planetary ices at UCL
NASA Astrophysics Data System (ADS)
Grindrod, P. M.; Fortes, A. D.; Wood, I. G.; Dobson, D.; Sammonds, P. R.; Stone-Drake, L.; Vocadlo, L.
2007-08-01
Using a suite of techniques and equipment, we conduct several different types of experiments on planetary ices at UCL. Samples are prepared in the Ice Physics Laboratory, which consists of a 5 chamber complex of inter-connected cold rooms, controllable from +30 to -30 deg C. Within this laboratory we have a functioning triaxial deformation cell operating at low temperature (down to -90 deg C) and high pressures (300 MPa), an Automatic Ice Fabric Analyser (AIFA) and a low-temperature microscope with CCD output. Polycrystalline samples, 40mm diameter by 100mm long, are compressed in the triaxial rig with a confining pressure; single crystal specimens are compressed in a separate uniaxial creep rig which operates at zero confining pressure for surface studies. A cold stage is also available for study of ice microstructural studies on our new Jeol JSM-6480LV SEM, which also allows tensile, compression and/or bending tests, with load ranges from less than 2N to 5000N. Finally, we also use a cold stage on a new PANalytical, X'pert PRO MPD, high resolution powder diffractometer to study the structure and phase behaviour of icy materials. Recent highlights of our work include: (1) derivation of a manufacturing process for methane clathrate at low temperatures, analysed in the X-Ray Diffraction Laboratory, for future rheological experiments, (2) analysed the growth behaviour of MS11, (3) refurbished and commenced calibration tests on the triaxial deformation cell using ice Ih, and (4) performed creep tests on gypsum and epsomite using the single crystal deformation cell. Further experiments will build on these preliminary results.
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...
Significant skin-tightening by closure of fractional ablative laser holes.
Russe, Elisabeth; Purschke, Martin; Limpiangkanan, Wikunda; Farinelli, William A; Wang, Ying; Doukas, Apostolos G; Sakamoto, Fernanda H; Wechselberger, Gottfried; Anderson, Richard Rox
2018-01-01
Ablative fractional laser treatment uses thousands of very small laser beam wounds to damage a fraction of the skin, which stimulates tissue remodeling. Each open micro-wound heals without scarring, but the amount of skin tightening achieved is limited. This animal study was performed to test the hypothesis that immediate temporary closure of fractional laser wounds could increase skin tightening after fractional ablative laser treatment. Four adult swine were used for the study; 98 square test sites (3 × 3 cm) were tattooed on the abdomen and flanks of each pig. An ablative fractional Erbium:YAG laser (Sciton Profile, Sciton Inc, Palo Alto, CA) was used to treat the test areas. A laser micro-spot fluence of 375 J/cm 2 was delivered in 150-250 microseconds pulses, resulting in an array of ablation channels extending 1.5 mm deep into the skin, with a spot size of 250 µm, with 10% treatment density. Immediately following laser exposure the resulting holes were closed using a stretched elastic adhesive dressing, which, when applied, recoiled and compressed the diameter of the ablation holes. The compressive dressings were removed after 7 days. This procedure was compared to removing the same amount of skin (10%) mechanically by specially designed 19 gauge coring needles, as well as to the same laser and coring methods without compression closure. Area and shape of test sites were measured by digital photography before and 28 days after treatment. Data analysis included compensation for animal growth, as measured by increase in the area of the untreated control sites. All treated and control sites healed within a week, without scarring evident at 28 days. Laser treatment combined with compressive wound closure caused significant shrinkage at 28 days compared with untreated control sites. The treated skin area was reduced by 11.5% (P = 0.0001). Needle coring with wound closure produced similar, significant shrinkage (8%, P < 0.0021), whereas laser and needle coring treatment without closure did not result in significant area reduction (P = 0.1289) compared with untreated control sites. Significant skin tightening can be achieved by immediate temporary non-invasive wound closure after short pulse Er:YAG fractional ablative laser treatment, as well as after mechanically removing skin with a coring needle. This approach may improve skin tightening after ablative laser treatments. Further clinical studies are necessary to confirm successful application in humans. Lasers Surg. Med. 50:64-69, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Application of orange essential oil as an antistaphylococcal agent in a dressing model.
Muthaiyan, Arunachalam; Biswas, Debabrata; Crandall, Philip G; Wilkinson, Brian J; Ricke, Steven C
2012-08-16
Staphylococcus aureus is the pathogen most often and prevalently involved in skin and soft tissue infections. In recent decades outbreaks of methicillin-resistant S. aureus (MRSA) have created major problems for skin therapy, and burn and wound care units. Topical antimicrobials are most important component of wound infection therapy. Alternative therapies are being sought for treatment of MRSA and one area of interest is the use of essential oils. With the increasing interest in the use and application of natural products, we screened the potential application of terpeneless cold pressed Valencia orange oil (CPV) for topical therapy against MRSA using an in vitro dressing model and skin keratinocyte cell culture model. The inhibitory effect of CPV was determined by disc diffusion vapor assay for MRSA and vancomycin intermediate-resistant S. aureus (VISA) strains. Antistaphylococcal effect of CPV in an in vitro dressing model was tested on S. aureus inoculated tryptic soya agar plate. Bactericidal effect of CPV on MRSA and VISA infected keratinocyte cells was examined by enumeration of extra- and intra-cellular bacterial cells at different treatment time points. Cytotoxic effects on human skin cells was tested by adding CPV to the keratinocyte (HEK001) cells grown in serum free KSFM media, and observed by phase-contrast microscope. CPV vapour effectively inhibited the MRSA and VISA strains in both disc diffusion vapour assay and in vitro dressing model. Compared to untreated control addition of 0.1% CPV to MRSA infected keratinocyte decreased the viable MRSA cells by 2 log CFU/mL in 1 h and in VISA strain 3 log CFU/mL reduction was observed in 1 h. After 3 h viable S. aureus cells were not detected in the 0.2% CPV treatment. Bactericidal concentration of CPV did not show any cytotoxic effect on the human skin keratinocyte cells in vitro. At lower concentration addition of CPV to keratinocytes infected with MRSA and VISA rapidly killed the bacterial cells without causing any toxic effect to the keratinocytes. Therefore, the results of this study warrant further in vivo study to evaluate the potential of CPV as a topical antistaphylococcal agent.
Comparison of two silver dressings for wound management in pediatric burns.
Jester, Ingo; Bohn, Ingo; Hannmann, Thorsten; Waag, Karl-Ludwig; Loff, Steffan
2008-11-01
Purpose. Silver wound dressings are widely used in the treatment of burns. Dressings differ in material characteristics, various antimicrobial activities, and ease of use. The purpose of this study was to evaluate both dressing performance and amount of pain during the dressing changes of 2 silver dressings Urgotul SSD® (Laboratoires Urgo, Chenove, France), and Contreet Ag® (Coloplast, Minneapolis, MN) in children. A retrospective cohort study was performed with 2 groups of 20 burns treated with Urgotul SSD and Contreet Ag until the wounds were healed or grafted. Seventy dressing changes in the Contreet Ag group and 67 dressing changes in the Urgotul group were evaluated. Every dressing change was assessed regarding the dressing performance (exudate, adherence, bleeding, and dressing application/removal), and pain. Pain was "absent or slight" in 61 (92%) dressing changes with Urgotul SSD, and in 60 (85%) of the dressing changes with Contreet Ag. Dressing application in the Urgotul group was more often "very easy" (n = 33; 49%) or "easy" (n = 32; 48%) than in the Contreet Ag group, "very easy" (n = 25; 35%), and "easy" (n = 42; 60%). Contreet Ag had a greater ability to absorb exudate ("very good" n = 60; 85%, and "good" n = 11; 15%) than Urgotul SSD ("very good" n = 34; 51%, and "good" n = 13; 19%). Urgotul SSD and Contreet Ag are comparable regarding pain during dressing change. The dressings differ in their ability to absorb exudate and ease of application. Both dressings provided nearly painless wound management, and therefore were highly accepted by the nurses and especially the children being treated.
Lee, Ye-Na; Lee, Jong Seok; Han, Seung-Kyu; Jung, Hye-Kyung
Our group has reported that negative-pressure wound therapy (NPWT) decreases tissue oxygenation by 84% in the foot of diabetic patients because the pad of the connecting drainage tube and foam sponge of the NPWT system compress the wound bed. The purpose of this study was to determine whether an NPWT modified dressing application reduces tissue oxygenation in the feet of persons with diabetes mellitus. A prospective, clinical, observational study. We enrolled 30 patients with diabetic mellitus; their mean age was 63.9 ± 11.2 years (mean ± standard deviation). All were cared for at the diabetic wound center at an academic tertiary medical center in South Korea between 2014 and January 2015. Transcutaneous partial oxygen pressures (TcpO2) were measured to determine tissue oxygenation levels beneath modified NPWT dressings. A TcpO2 sensor was fixed at the tarsometatarsal area of the contralateral unwounded foot. A negative pressure of -125 mm Hg was applied until TcpO2 reached a plateau state; values were measured before, during, and after the modified NPWT. The Wilcoxon' and Mann-Whitney U tests were used to compare differences between these measurements. TcpO2 levels decreased by 26% during the modified NPWT. Mean TcpO2 values before, during, and after turning off the therapy were 54.3 ± 15.3 mm Hg, 41.6 ± 16.3 mm Hg, and 53.3 ± 15.6 mm Hg (P < .05), respectively. Applying NPWT without the pad of the connecting drainage tube significantly reduces the amount of tissue oxygenation loss beneath foam dressings on the skin of the foot dorsum in diabetic patients.
Post-surgical wound management of pilonidal cysts with a haemoglobin spray: a case series.
Mustafi, N; Engels, P
2016-04-01
Painful acute cysts in the natal cleft or lower back, known as pilonidal sinus disease, are a severe burden to many younger patients. Although surgical intervention is the preferred first line treatment, postsurgical wound healing disturbances are frequently reported due to infection or other complications. Different treatment options of pilonidal cysts have been discussed in the literature, however, no standardised guideline for the postsurgical wound treatment is available. After surgery, a common recommended treatment to patients is rinsing the wound with clean water and dressing with a sterile compress. We present a case series of seven patients with wounds healing by secondary intention after surgical intervention of a pilonidal cyst. The average age of the patients was 40 years old. Of the seven patients, three had developed a wound healing disturbance, one wound had started to develop a fibrin coating and three were in a good condition. The applied wound care regimens comprised appropriate mechanical or autolytic debridement, rinsing with an antimicrobial solution, haemoglobin application, and primary and secondary dressings. In all seven cases a complete wound closure was achieved within an average of 76 days with six out of seven wounds achieving wound closure within 23-98 days. Aesthetic appearance was deemed excellent in five out of seven cases excellent and acceptable in one. Treatment of one case with a sustained healing disturbance did result in wound closure but with a poor aesthetic outcome and an extensive cicatrisation of the new tissue. Based on these results we recommend that to avoid healing disturbances of wounds healing by secondary intention after surgical pilonidal cyst intervention, an adequate wound care regime comprising appropriate wound debridement, rinsing, topically applied haemoglobin and adequate wound dressing is recommendable as early as possible after surgery.
Choosing a Wound Dressing Based on Common Wound Characteristics
Dabiri, Ganary; Damstetter, Elizabeth; Phillips, Tania
2016-01-01
Significance: Chronic wounds are a major healthcare burden.The practitioner should have an appropriate understanding of both the etiology of the wound as well as the optimal type of dressings to use. Fundamental wound characteristics may be used to guide the practitioner's choice of dressings. The identification of optimal dressings to use for a particular wound type is an important element in facilitating wound healing. Recent Advances: Researchers have sought to design wound dressings that aim to optimize each stage in the healing process. In addition, dressings have been designed to target and kill infection-causing bacteria, with the incorporation of antimicrobial agents. Critical Issues: Chronic wounds are frequently dynamic in presentation, and the numerous wound dressings available make dressing selection challenging for the practitioner. Choosing the correct dressing decreases time to healing, provides cost-effective care, and improves patient quality of life. Future Directions: Research into the mechanisms of wound healing has enhanced our ability to heal chronic wounds at a faster rate through the use of moisture-retentive dressings. Newer dressings are incorporating the use of nanotechnology by incorporating miniature electrical sensors into the dressing. These dressings are engineered to detect changes in a wound environment and alert the patient or practitioner by altering the color of the dressing or sending a message to a smartphone. Additional investigations are underway that incorporate biologic material such as stem cells into dressings. PMID:26858913
Browning, R; Phelps, O; Chisley, C; Getz, W R; Hollis, T; Leite-Browning, M L
2012-03-01
Bucklings (n = 275) from a complete diallel of Boer, Kiko, and Spanish meat goats were slaughtered at 7 mo of age (4 mo postweaning) to evaluate genetic effects on carcass yield. Breed of sire did not affect (P > 0.05) live, carcass, and primal weights. Conversely, breed of dam was a consistently significant source of variation for carcass weight traits. Kiko dams produced kids with heavier (P < 0.05) live, carcass, and primal weights than Boer dams. Weights from Spanish dams were intermediate to Boer and Kiko with the significance of differences varying by trait. Cold carcass dressing percent was affected (P < 0.01) by breeds of sire and dam. Boer sires decreased (P < 0.05) dressing percent compared with Kiko and Spanish sires. Dressing percent was also less (P < 0.01) from Boer dams than from Kiko dams; Spanish dams were intermediate and did not differ (P > 0.05) from Boer or Kiko. Subjective conformation scores for muscularity were affected (P < 0.01) by breeds of sire and dam. Boer-sired kids had better (P < 0.01) live scores than Kiko-sired kids. Progeny of Boer dams had better (P < 0.05) live scores than progeny of Spanish dams. Boer-sired kids also had better carcass scores (P < 0.05) than Kiko-sired and Spanish-sired kids. Breed differences for primal cut proportions were negligible. Proportional boneless meat yields did not vary (P > 0.05) by breeds of sire or dam. Direct effects of Boer were negative for carcass weight, dressing percent, and shoulder weight and positive for proportional leg weight. Direct effects of Kiko were positive for carcass weight and shoulder weight and negative for proportional leg weight. Direct effects of Spanish did not differ (P > 0.10) from 0 for any trait tested. Heterosis levels were similar among breed pairings. Heterosis was substantial (P ≤ 0.05) for live, carcass, and primal weights (5 to 9%) but not for dressing percent, proportional boneless meat yield, or primal weight proportions (<2%). Significant genetic variation was observed among goat breeds for carcass yield traits. Dam breed was more influential than sire breed. Boer germplasm was not superior to Kiko or Spanish germplasm for carcass yield when semi-intensively managed on humid, subtropical pasture. Results emphasize the importance of comparative breed evaluations to provide industry with reliable information on carcass yield among goat genotypes.
Improving the cold flow properties of biodiesel by fractionation
USDA-ARS?s Scientific Manuscript database
Production of biodiesel is increasing world-wide and contributing to the growing development of renewable alternative fuels. Biodiesel has many fuel properties such as density, viscosity, lubricity, and cetane number that make it compatible for combustion in compression-ignition (diesel) engines. ...
Evaluation of a non-adherent, povidone-iodine dressing in a case series of chronic wounds.
Campbell, N; Campbell, D
2013-08-01
Here we report a product evaluation for a non-adherent, povidone-iodine (PVP-I) dressing, determining the clinical need for the product, performing a literature review, clinical evaluation and cost-analysis, and developing a recommendation. This evaluation included 20 patients who experienced dressing pain with the previous antimicrobial dressing. Two patients discontinued the evaluation and four ulcers were non-healing; the remaining wounds closed with the PVP-I dressing. Patients indicated a preference for the PVP-I dressing, primarily due to lack of dressing pain. The PVP-I dressing was also the most cost-efficient.
Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick
2012-08-01
It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Hormbrey, E; Pandya, A; Giele, H
2003-07-01
Painful split-skin-graft donor sites remain a common problem for patients. We undertook a prospective randomised trial to examine the comparative comfort and ease of care of two different donor-site dressings. One dressing is the alginate Kaltostat, the standard plastic-surgical dressing in the UK and abroad, and the other is the adhesive retention tape Mefix, a novel use of a readily available dressing. We randomised 50 patients requiring split-skin grafts to receive either alginate (Kaltostat) or retention (Mefix) donor-site dressings. Dressings were assessed by interview and questionnaire at 24, 72 h and 2 weeks, and by wound review at 2 weeks. Retention dressings were found to be more comfortable, required less nursing intervention and allowed patients easier mobility with a greater range of daily activities, especially washing, without compromising wound healing. We recommend adhesive retention dressings as cost-effective comfortable dressings, which readily conform to any donor site.
Deandrea, Maurilio; Limone, Paolo; Basso, Edoardo; Mormile, Alberto; Ragazzoni, Federico; Gamarra, Elena; Spiezia, Stefano; Faggiano, Antongiulio; Colao, Annamaria; Molinari, Filippo; Garberoglio, Roberto
2008-05-01
The aim of the study was to define the effectiveness and safety of ultrasound-guided percutaneous radiofrequency (RF) thermal ablation in the treatment of compressive solid benign thyroid nodules. Thirty-one patients not eligible for surgery or radioiodine (131I) treatment underwent RF ablation for benign nodules; a total of 33 nodules were treated (2 patients had 2 nodules treated in the same session): 10 cold nodules and 23 hyperfunctioning. Fourteen patients complained of compressive symptoms. Nodule volume, thyroid function and compressive symptoms were evaluated before treatment and at 1, 3 and 6 mo. Ultrasound-guided RF ablation was performed using a Starbust RITA needle, with nine expandable prongs; total exposure time was 6 to 10 min at 95 degrees C in one area or more of the nodule. Baseline volume (measured at the time of RF ablation) was 27.7 +/- 21.5 mL (mean +/- SD), but significantly decreased during follow-up: 19.2 +/- 16.2 at 1 mo (-32.7%; p < 0.001), 15.9 +/- 14.1 mL at 3 mo (-46.4 %; p < 0.001) and 14.6 +/- 12.6 mL at 6 mo (-50.7%; p < 0.001). After treatment, all patients with cold nodules remained euthyroid: five patients with hot nodules normalized thyroid function, and the remaining sixteen showed a partial remission of hyperthyroidism. Besides a sensation of heat and mild swelling of the neck, no major complications were observed. Improvement in compressive symptoms was reported by 13 patients, with a reduction on severity scale from 6.1 +/- 1.4 to 2.2 +/- 1.9 (p < 0.0001). Radiofrequency was effective and safe in reducing volume by about 50% and compressive symptoms in large benign nodules. Hyperfunction was fully controlled in 24% of patients and partially reduced in the others.
Sabo, Matthew; Le, Lam; Yaakov, Raphael A; Carter, Marissa; Serena, Thomas E
2018-04-01
Chronic wounds (ie, wounds that fail to progress through a normal, orderly, timely sequence of repair) continue to pose significant clinical and economic burdens. A prospective, descriptive, 3-week post-marketing surveillance study was conducted across 3 wound care centers in the United States to evaluate the effectiveness of a collagen calcium alginate dressing on chronic wounds in conjunction with standard care (SC) practices (eg, offloading, debridement, compression) to support healing. Eligible participants had to be >18 years of age, have at least 1 chronic wound, and no known sensitivity to collagen. Demographic characteristics were recorded at the screening visit on case report forms. At each visit, wound-related pain was assessed using the Visual Analog Scale along with wound characteristics including size (using digital planimetry), wound exudate (minimal, moderate, heavy), and odor (none, mild). Participants were monitored for adverse events as well as infection based on signs and symptoms in and around the local wound bed, the deeper structures, and the surrounding skin. An intention-to-treat approach was used for all analyses. If an observation was missing, the last observation carried forward principle was used. For wounds that healed, pain and exudate were set to 0 (no pain/exudate) at visit 4. Descriptive, paired t tests and the Wilcoxon signed rank test were used to analyze the data. Of the 31 participants (15 men, 16 women, mean age 66.6 years), most (13, 42%) had a diabetic foot ulcer or venous leg ulcer (10, 32%); median duration of all wounds was 148 days. Thirty (30) patients completed the study. The mean number of comorbidities was 10.6 ± 6.3, and patients used a mean of 9.3 ± 5.64 prescription or over-the-counter medications. For all wounds combined, mean wound area was 4.8 ± 8.38 cm2 at baseline. At week 3, a decrease in wound area of 38.1% was noted (median: 45% ± 42.54; P = .006); 3 wounds healed completely. The change in wound exudate level from visit 1 to visit 4 was statistically significant (P = .006). No adverse events or infections occurred. In this population, the use of etiology-appropriate SC and a collagen calcium alginate dressing resulted in a decrease in wound area after 3 weeks of care. Longer-term studies to confirm these observations and controlled clinical studies to compare the effects of this dressing to other nongauze dressing treatments are needed.
Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study.
McColl, David; Cartlidge, Brian; Connolly, Patricia
2007-10-01
Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time. A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate flow. Eight monitoring points, situated beneath the test dressing, allow the moisture profile across the complete dressing to be measured both during and after fluid injection. The system has been used to evaluate the performance of four foam dressings, a composite hydrofibre dressing and a film dressing. Stark contrasts in the performance of the wound contact layer were found between the different wound dressing types. The composite hydrofibre dressing retained moisture at the wound interface throughout the experiments while areas of the foam dressing quickly became dry, even during constant injection of fluid. The abundance of sensors allowed a moisture map of the surface of the wound dressing to be constructed, illustrating that the moisture profile was not uniform across several of the dressings tested during absorption and evaporation of liquid. These results raise questions as to how the dressings behave on a wound in vivo and indicate the need for a similar clinical monitoring system for tracking wound moisture levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGregor, R.; Doherty, P.; Hornbach, D.
1995-12-31
Nuclear Steam Generator (SG) service reliability and longevity have been seriously affected worldwide by corrosion at the tube-to-tubesheet joint expansion. Current SG designs for new facilities and replacement projects enhance corrosion resistance through the use of advanced tubing materials and improved joint design and fabrication techniques. Here, transition zones of hydraulic expansions have undergone detailed experimental evaluation to define residual stress and cold-work distribution on and below the secondary-side surface. Using X-ray diffraction techniques, with supporting finite element analysis, variations are compared in tubing metallurgical condition, tube/pitch geometry, expansion pressure, and tube-to-hole clearance. Initial measurements to characterize the unexpanded tubemore » reveal compressive stresses associated with a thin work-hardened layer on the outer surface of the tube. The gradient of cold-work was measured as 3% to 0% within .001 inch of the surface. The levels and character of residual stresses following hydraulic expansion are primarily dependent on this work-hardened surface layer and initial stress state that is unique to each tube fabrication process. Tensile stresses following expansion are less than 25% of the local yield stress and are found on the transition in a narrow circumferential band at the immediate tube surface (< .0002 inch/0.005 mm depth). The measurements otherwise indicate a predominance of compressive stresses on and below the secondary-side surface of the transition zone. Excellent resistance to SWSCC initiation is offered by the low levels of tensile stress and cold-work. Propagation of any possible cracking would be deterred by the compressive stress field that surrounds this small volume of tensile material.« less
Shock compression response of cold-rolled Ni/Al multilayer composites
Specht, Paul E.; Weihs, Timothy P.; Thadhani, Naresh N.
2017-01-06
Uniaxial strain, plate-on-plate impact experiments were performed on cold-rolled Ni/Al multilayer composites and the resulting Hugoniot was determined through time-resolved measurements combined with impedance matching. The experimental Hugoniot agreed with that previously predicted by two dimensional (2D) meso-scale calculations. Additional 2D meso-scale simulations were performed using the same computational method as the prior study to reproduce the experimentally measured free surface velocities and stress profiles. Finally, these simulations accurately replicated the experimental profiles, providing additional validation for the previous computational work.
ERIC Educational Resources Information Center
Birel, Firat Kiyas
2016-01-01
Problem Statement: Dressing for school has been intensely disputed and has led to periodic changes in dress codes since the foundation of the Turkish republic. Practitioners have tried to put some new practices related to school dress codes into practice for redressing former dress code issues involving mandatory dress standards for both students…
Australasian survey of split skin graft donor site dressings.
Lyall, P W; Sinclair, S W
2000-02-01
There is an ever increasing array of products available for wound dressings. The aim of the present study was to establish which dressings should be used as standard controls for future studies; what factors are regarded as most important in assessing a dressing; what the level of satisfaction is with the available products; what the strengths and weaknesses of the commonly used dressings are; and what dressings would be preferred if cost were no issue. A postal survey was sent to every plastic and reconstructive surgeon registered in Australasia (n = 217). A total of 53% responded. The most commonly used dressing type overall is the calcium alginates, despite the fact that they were not the highest performing dressings. This is also the most commonly used in Australia. In contrast scarlet red is still used most commonly in New Zealand. The level of satisfaction with the most commonly used dressing varied very little. The factor regarded most important was patient comfort level. A profile of the commonly used dressing was constructed. Calcium alginates and or scarlet red should be used as the control for new product comparisons. Most of the respondents were satisfied with their preferred dressing and were not interested in trying alternative dressings.
Compressible Turbulent Channel Flows: DNS Results and Modeling
NASA Technical Reports Server (NTRS)
Huang, P. G.; Coleman, G. N.; Bradshaw, P.; Rai, Man Mohan (Technical Monitor)
1994-01-01
The present paper addresses some topical issues in modeling compressible turbulent shear flows. The work is based on direct numerical simulation of two supersonic fully developed channel flows between very cold isothermal walls. Detailed decomposition and analysis of terms appearing in the momentum and energy equations are presented. The simulation results are used to provide insights into differences between conventional time-and Favre-averaging of the mean-flow and turbulent quantities. Study of the turbulence energy budget for the two cases shows that the compressibility effects due to turbulent density and pressure fluctuations are insignificant. In particular, the dilatational dissipation and the mean product of the pressure and dilatation fluctuations are very small, contrary to the results of simulations for sheared homogeneous compressible turbulence and to recent proposals for models for general compressible turbulent flows. This provides a possible explanation of why the Van Driest density-weighted transformation is so successful in correlating compressible boundary layer data. Finally, it is found that the DNS data do not support the strong Reynolds analogy. A more general representation of the analogy is analysed and shown to match the DNS data very well.
NASA Astrophysics Data System (ADS)
Wüster, S.; Rost, J.-M.
2018-02-01
We review Rydberg aggregates, assemblies of a few Rydberg atoms exhibiting energy transport through collective eigenstates, considering isolated atoms or assemblies embedded within clouds of cold ground-state atoms. We classify Rydberg aggregates, and provide an overview of their possible applications as quantum simulators for phenomena from chemical or biological physics. Our main focus is on flexible Rydberg aggregates, in which atomic motion is an essential feature. In these, simultaneous control over Rydberg-Rydberg interactions, external trapping and electronic energies, allows Born-Oppenheimer surfaces for the motion of the entire aggregate to be tailored as desired. This is illustrated with theory proposals towards the demonstration of joint motion and excitation transport, conical intersections and non-adiabatic effects. Additional flexibility for quantum simulations is enabled by the use of dressed dipole-dipole interactions or the embedding of the aggregate in a cold gas or Bose-Einstein condensate environment. Finally we provide some guidance regarding the parameter regimes that are most suitable for the realization of either static or flexible Rydberg aggregates based on Li or Rb atoms. The current status of experimental progress towards enabling Rydberg aggregates is also reviewed.
NASA Astrophysics Data System (ADS)
Ćirić, J.; Lukić, M.; Radulović, S.; Janjić, J.; Glamočlija, N.; Marković, R.; Baltić, M. Ž.
2017-09-01
The objective was to study the relationships between the carcass characteristics and meat composition of young Simmental beef, classified with regard to conformation and degree of fatness scores, and total lipid content, depending on gender. For this purpose, 90 animals (60 male and 30 female Simmental beef cattle) were analysed. The results of the study showed that gender affected carcass measurement scores and chemical composition of meat through its important effect on overall animal fatness. Referring to correlations, male carcass conformation score was negatively related to slaughter weight, total lipid content and fatness score. On the other hand, slaughter weight, hot and cold carcass weight, dressing percentage and carcass conformation was positively related to fatness score, all of them being significant. However, female carcass conformation score was positively related to slaughter weight, total lipid content and fatness score. Hot and cold carcass weights of female Simmental beef cattle were positively correlated to slaughter weight, total lipid content and carcass conformation score. Carcass conformation score and fatness score were affected by gender of young Simmental beef cattle.
THE EFFECT OF LASER SHOCK PEENING ON THE LIFE AND FAILURE MODE OF A COLD PILGER DIE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavender, Curt A.; Hong, Sung-tae; Smith, Mark T.
2008-08-11
The laser shock peening process was used to increase fatigue life of pilger dies made of A2 tool steel by imparting compressive residual stresses to fatigue prone areas of the dies. The result of X-Ray diffraction analysis indicated that deep, high- magnitude compressive residual stresses were generated by the laser shock peening process, and the peened dies exhibited a significant increase of in-service life. Fractography of the failed dies indicates that the fracture mechanism was altered by the peening process.
Edwards, Melannie; Rickard, Claire M; Rapchuk, Ivan; Corley, Amanda; Marsh, Nicole; Spooner, Amy J; Mihala, Gabor; Fraser, John F
2014-09-01
To improve arterial catheter (AC) securement and reduce AC failure; to assess feasibility of a large randomised controlled trial. A four-arm, parallel, randomised, controlled, non-blinded pilot trial with 195 intensive care patients taking part, in a tertiary referral hospital in Brisbane, Australia from May to November 2012. Standard polyurethane (SPU) dressing (controls); bordered polyurethane (BPU) + SPU dressing; tissue adhesive (TA) + SPU dressing; and sutureless securement device (SSD) + SPU dressing (no sutures used). AC failure, ie, complete dislodgement, occlusion (monitor failure, inability to infuse or fluid leaking), pain or infection (local or blood). Median AC dwell time was 26.2 hours and was comparable between groups. AC failure occurred in 26/195 patients (13%). AC failure was significantly worse with SPU dressings (10/47 [21%]) than with BPU + SPU dressings (2/ 43 [5%]; P = 0.03), but not significantly different to TA + SPU (6/56 [11%]; P = 0.18) or SSD + SPU (8/49 [16%]; P = 0.61). The dressing applied at AC insertion lasted until AC removal in 68% of controls; 56% of BPU + SPU dressings; 73% of TA + SPU dressings; and 80% of SSD + SPU dressings (all P > 0.05). There were no infections or serious adverse events. Patient and staff satisfaction with all products was high. Median costs (labour and materials) for securement per patient were significantly higher in all groups compared with the control group (SPU, $3.48 [IQR, $3.48-$9.79]; BPU + SPU, $5.07 [IQR, $5.07-$12.99]; SSD + SPU, $10.90 [IQR, $10.90-$10.90]; TA + SPU, $17.70 [IQR, $17.70-$38.36]; all P < 0.01). AC failure occurred significantly less often with BPU + SPU dressings than with SPU dressings. TA + SPU and SSD + SPU dressings should be further investigated and compared with BPU + SPU dressings as controls. The novel approach of TA + SPU dressings appeared safe and feasible.
NASA Astrophysics Data System (ADS)
Manikandan, P.; Balaji, S.; Sukumar, S.; Sivakumar, M.
2017-06-01
This paper presents the strength and behaviour of web stiffened cold formed steel channel column with various types of edge stiffener under axial compression. An accurate finite element model is developed to simulate the tests results of the proposed section. The finite element model is verified by the test results and good correlation is achieved. The failure modes local, distortional, flexural buckling as well as the interaction between these modes is found in this study. The column strength predicted from the parametric study is compared with the nominal strength calculated by using the direct strength method for cold formed steel members. The reliability of this method is evaluated and suitable modification factor is proposed.
Dressing remedies: a concept for improving access to and use of dressings in nursing homes.
Clarkson, A
2007-01-01
Delays in accessing dressings prescribed by general practitioners can result in the inappropriate use of dressings on more than one resident in nursing homes. The dressing remedies concept was developed to overcomes this problem.
Two piston V-type Stirling engine
Corey, John A.
1987-01-01
A two piston Stirling engine which includes a heat exchanger arrangement placing the cooler and regenerator directly adjacent the compression space for minimal cold duct volume; a sealing arrangement which eliminates the need for piston seals, crossheads and piston rods; and a simplified power control system.
Xiao, Xin; Zhang, Peng; Meng, Zhao-Nan; Li, Ming
2015-04-01
Nitrates and eutectic nitrate mixtures are considered as potential phase change materials (PCMs) for the middle-temperature-range solar energy storage applications. But the extensive utilization is restricted by the poor thermal conductivity and thermal stability. In the present study, sodium nitrate-potassium nitrate eutectic mixture was used as the base PCM, and expanded graphite (EG) was added to the mixture so as to improve the thermal conductivities. The elaboration method consists of a physically mixing of salt powders with or without EG, and the composite PCMs were cold-compressed to form shape-stabilized PCMs at room temperature. The thermal conductivities of the composite PCMs fabricated by cold-compression were investigated at different temperatures by the steady state method. The results showed that the addition of EG significantly enhanced the thermal conductivities. The thermal conductivities of pure nitrates and nitrates/EG composite PCMs in solid state showed the behavior of temperature dependant, and they slightly decreased with the increase of the temperature.
Use of a novel epidermal harvesting system in resource-poor countries.
Serena, Thomas; Francius, Adler; Taylor, Cristin; MacDonald, John
2015-03-01
The 2010 earthquake in Port-au-Prince, Haiti, highlighted the need for wound care in resource-poor countries. Subsequently, the University of Miami in Florida established one of the first interprofessional wound care centers located at Bernard Mevs Hospital in the central portion of Port-au-Prince, caring for patients with acute and chronic wounds. In 2012, the authors used a novel epidermal harvesting system (CelluTome Epidermal Harvesting System; Kinetic Concepts Inc, San Antonio, Texas) to harvest epithelium to be grafted on 7 patients at the Mevs Hospital with longstanding wounds. Epidermal microblisters were obtained from each patient's thigh using the CelluTome Epidermal Harvesting System. After 35 minutes, microblisters were raised using the device harvester, and an adhesive dressing was inserted into the harvester for transfer to the wound site. In patients with lower-extremity wounds, a 2-layer compression dressing was placed over epidermal grafts. Six of the 7 wounds improved or achieved complete closure in 4 weeks. One of the patients with a 2-year-old thigh wound failed to demonstrate improvement; this may have been secondary to an inability to adequately secure the graft. All donor sites healed without any visible scarring. The authors were able to conclude that epidermal grafting may represent a viable reconstructive option for patients in resource-poor countries.
Matiasek, J; Domig, K J; Djedovic, G; Babeluk, R; Assadian, O
2017-05-02
The aim of this study was to investigate the bacterial bioburden in experimental in vitro wounds during the application of conventional negative pressure wound therapy (NPWT), with and without antimicrobial dressings (polyhexanide, silver), against NPWT instillation of octenidine. Experimental wounds produced in an in vitro porcine wound model were homogenously contaminated with bacterial suspension and treated with NPWT and different options. Group A: non-antimicrobial polyurethane foam dressing; group B: antimicrobial polyurethane foam dressing containing silver; group C: antimicrobial gauze dressing containing polyhexanide; group D: non-antimicrobial polyurethane foam dressing intermittently irrigated with octenidine; group E: negative control (non-antimicrobial polyurethane foam dressing without NPWT). Standard biopsies were harvested after 24 and 28 hours. This study demonstrated that the use of NPWT with intermitted instillation of octenidine (group D) or application of silver-based polyurethane foam dressings (group B) is significantly superior against Staphylococcus aureus colonisation in experimental wounds compared with non-antimicrobial polyurethane foam dressing (group A) after 48 hours. Surprisingly, the polyhexanide-based dressing (group C) used in this model showed no statistical significant effect compared with the control group (group E) after 24 or 48 hours of treatment. Both intermitted instillation of octenidine and silver-based dressings in standard NPWT were significantly superior compared with non-antimicrobial polyurethane foam dressings or PHMB coated gauze dressing after 48 hours.
Exit-Site Dressing and Infection in Peritoneal Dialysis: A Randomized Controlled Pilot Trial.
Mushahar, Lily; Mei, Lim Wei; Yusuf, Wan Shaariah; Sivathasan, Sudhaharan; Kamaruddin, Norilah; Idzham, Nor Juliana Mohd
2016-01-01
♦ Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate of PD-related infection. ♦ A prospective randomized controlled study was conducted in prevalent PD patients at the Hospital Tuanku Jaafar Seremban, Negeri Sembilan, Malaysia, from April 2011 until April 2013. All patients were required to perform daily washing of the exit site with antibacterial soap during a shower. In the dressing group (n = 54), patients were required to clean their exit site using povidone-iodine after drying, followed by topical mupirocin antibiotic application to the exit site. The exit site was then covered with a sterile gauze dressing and the catheter immobilized with tape. In the non-dressing group (n = 54), patients were not required to do any further dressing after drying. They were only required to apply mupirocin cream to the exit site and then left the exit site uncovered. The catheter was immobilized with tape. The primary outcome was ESI. The secondary outcomes were evidence of tunnel infection or peritonitis. ♦ A total of 97 patients completed the study. There were a total of 12 ESI episodes: 4 episodes in 4 patients in the dressing group vs 8 episodes in 4 patients in the non-dressing group. This corresponds to 1 episode per 241.3 patient-months vs 1 episode per 111.1 patient-months in the dressing and non-dressing groups respectively. Median time to first ESI episode was shorter in the non-dressing than in the dressing group, but not significant (p = 0.25). The incidence of gram-positive ESI in both groups was similar. There were no gram-negative ESI in the non-dressing group compared with 2 in the dressing group. The peritonitis rate was 1 per 37.1 patient-month in the dressing group and 1 per 44.4 patient-months in the non-dressing group. Median time to first peritonitis episode was significantly shorter in the dressing group compared to non-dressing (p = 0.03). There was no impact of dressing disruptions in the occurrence of major PD catheter-related infection. ♦ Use of a non-dressing technique with only prophylactic topical mupirocin cream application is effective in preventing PD-related infection. The non-dressing technique is more cost-effective and convenient for PD patients, with fewer disposables. Copyright © 2016 International Society for Peritoneal Dialysis.
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate.
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L; Carty, Neal; Johnson, Peter
2015-01-01
Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes.
Closed dressings after laser skin resurfacing.
Newman, J P; Koch, R J; Goode, R L
1998-07-01
To evaluate the safety, efficacy, and patient acceptance of closed dressings after full facial resurfacing with the carbon dioxide laser. Prospective cohort of men and women undergoing full facial carbon dioxide laser resurfacing. Ambulatory surgical center at a university hospital. Forty consecutive patients randomized to 1 of 4 dressing groups. All patients underwent full facial resurfacing with a carbon dioxide laser system. One of 5 closed dressings (single- or 3-layer composite foam, plastic mesh, hydrogel, or polymer film) was placed immediately after the procedure. Closed dressings were changed on postoperative day 2 and removed on postoperative day 4. Objective postoperative criteria of erythema, scarring, reepithelialization, and surface irregularities were recorded and photodocumented. Comparisons were made among the closed dressing groups as well as with a group of historical control subjects treated with open dressings. The ease of application, office time for preparation and application, and cost of the individual dressings were collected. Patient characteristics of overall acceptance, comfort, and ease of maintenance were recorded with a visual analog scale. There were no complications of scarring, surface irregularities, or contact dermatitis from the application or maintenance of the closed dressings. There were no significant differences in the number of days of postoperative erythema or in the rate of facial reepithelialization among the groups. Most patients preferred not to continue with the closed dressings past 2 days. Positive features from the use of closed dressings included reduction in crust formation, decreased pruritus, decreased erythema, and decreased postoperative pain, compared with historical controls. Negative features included time in preparation and application of the dressings. Costs ranged from $9.79 to $50 per dressing change. Closed dressings are safe and offer benefits noted during the first 4 postoperative days. Patients can be expected to maintain a closed dressing for at least 24 hours but no longer than 4 days. The positive features of closed dressings and patient acceptance outweigh the cost and office time involved with their application and maintenance.
NASA Astrophysics Data System (ADS)
Görtan, Mehmet Okan
2018-05-01
Cold extrusion processes are distinguished by their low material usage as well as great efficiency in the production of mid-range and large component series. Although majority of the cold extruded parts are produced using die systems containing multiple forming stages, this subject has rarely been investigated so far. Therefore, the characteristics of multi-stage cold forward rod extrusion is studied in the current work using thermo-mechanically coupled finite element (FE) analysis. A case hardening steel, 16MnCr5 (1.7131) was used as experimental material. Its strain, strain rate and temperature dependent mechanical characteristics were determined using compression testing and modeled in FE simulations via a Johnson-Cook material model. Friction coefficients for the same material while in contact with a tool steel (1.2379) were determined dependent on temperature and contact pressure using sliding compression test (SCT) and modeled by an adaptive friction model developed by the author. In the first set of simulations, rod material with a diameter of 14.9 mm was extruded down to a diameter of 9.6 mm in a single step using three different die opening angles (2α); 20°, 40° and 60°. In the second set of investigations, the same rod was reduced first to 12 mm and then to 9.6 mm in two steps within the same forming die. Press forces, contact normal stresses between extruded material and forming die, material temperature and axial stresses are compared in these two set of simulations and the differences are discussed.
Improvements in Fabrication of Sand/Binder Cores for Casting
NASA Technical Reports Server (NTRS)
Bakhitiyarov, Sayavur I.; Overfelt, Ruel A.; Adanur, Sabit
2005-01-01
Three improvements have been devised for the cold-box process, which is a special molding process used to make sand/binder cores for casting hollow metal parts. These improvements are: The use of fiber-reinforced composite binder materials (in contradistinction to the non-fiber-reinforced binders used heretofore), The substitution of a directed-vortex core-blowing subprocess for a prior core-blowing process that involved a movable gassing plate, and The use of filters made from filtration-grade fabrics to prevent clogging of vents. For reasons that exceed the scope of this article, most foundries have adopted the cold-box process for making cores for casting metals. However, this process is not widely known outside the metal-casting industry; therefore, a description of pertinent aspects of the cold-box process is prerequisite to a meaningful description of the aforementioned improvements. In the cold-box process as practiced heretofore, sand is first mixed with a phenolic resin (considered to be part 1 of a three-part binder) and an isocyanate resin (part 2 of the binder). Then by use of compressed air, the mixture is blown into a core box, which is a mold for forming the core. Next, an amine gas (part 3 of the binder) that acts as a catalyst for polymerization of parts 1 and 2 is blown through the core box. Alternatively, a liquid amine that vaporizes during polymerization can be incorporated into the sand/resin mixture. Once polymerization is complete, the amine gas is purged from the core box by use of compressed air. The finished core is then removed from the core box.
Effects of boning method and postmortem aging on meat quality characteristics of pork loin.
Li, Chunbao; Wu, Juqing; Zhang, Nan; Zhang, Song; Liu, Juan; Li, Jinping; Li, Hongmin; Feng, Xianchao; Han, Yanqing; Zhu, Zhiyuan; Xu, Xinglian; Zhou, Guanghong
2009-10-01
This work investigated the effects of boning method and postmortem aging on pork loin color, shearing value and sensory attributes. Two experiments were assigned. In Experiment I, 30 Chinese native black pigs were slaughtered and their carcasses were divided into three groups: (i) hot-boning: carcasses were fabricated within 45 min postmortem just after dressing; (ii) cold boning at 24 h: carcasses were fabricated after chilling at 0 degrees C for 24 h; (iii) cold boning at 36 h: carcasses were fabricated after chilling at 0 degrees C for 36 h. In Experiment II, right sides of the second group in Experiment I were used and primal cuts were vacuum packed and aged for 1 day, 8 days and 16 days. Pork loins (Longissimus lumborum) were used for color measurement, shearing test, and sensory evaluation. Among three boning methods, cold-boning at 36 h postmortem had the advantages of giving muscles a better color, the lowest cooking loss and cooked shearing value, and the highest sensory tenderness, juiciness, flavor and overall liking. Postmortem aging could improve pork quality characteristics, but it is not the fact that the longer aging time is, the better pork quality would be. Eight days may be enough to obtain an acceptable sensory attribute. These results are meaningful for pork processing and pork consumption.
McDonald, Kyla P.; Ma, Lili
2015-01-01
This research explored whether children judge the knowledge state of others and selectively learn novel information from them based on how they dress. The results indicated that 4- and 6-year-olds identified a formally dressed individual as more knowledgeable about new things in general than a casually dressed one (Study 1). Moreover, children displayed an overall preference to seek help from a formally dressed individual rather than a casually dressed one when learning about novel objects and animals (Study 2). These findings are discussed in relation to the halo effect, and may have important implications for child educators regarding how instructor dress might influence young students’ knowledge attribution and learning preferences. PMID:26636980
Are biopolymers potential deodourising agents in wound management?
Lee, G; Anand, S C; Rajendran, S
2009-07-01
To investigate the odour-adsorbing properties of biopolymers, with a view to using the findings to develop a novel dressing with odour-adsorbing properties. The odour-adsorbing properties of a selection of biopolymers (aloe vera, tea tree oil, neem oil and manuka honey) and three commercially available dressings containing activated charcoal cloth (ACC) were quantitatively assessed using laboratory test equipment. An aloe vera-containing composite dressing, designed and developed by the authors, was also compared with the ACC dressings. Aloe vera was the most adsorbent of the biopolymers and a 40% dilution had comparable values to those of the ACC dressings. Furthermore, values for the novel composite dressing were similar to those of the ACC dressings. The novel composite dressing may be a potential alternative to ACC dressings, and has the added advantages of having antimicrobial properties as well as the ability to promote a moist wound environment. However, more research is needed.
Dressing disrupted: negotiating care through the materiality of dress in the context of dementia.
Buse, Christina; Twigg, Julia
2018-02-01
This paper explores how the materiality of dress mediates and shapes practices of care in the context of dementia. Earlier research called for an approach to conceptualising care that recognised the role played by everyday artefacts. We extend this to a consideration of dress and dressing the body in relation to people with dementia that involves the direct manipulation of material objects, as well as the materiality of bodies. The paper draws on an ESRC funded study Dementia and Dress, which examined experiences of dress for people with dementia, families and care-workers using ethnographic and qualitative methods. Our analysis explores the process of dressing the body, the physicality of guiding and manipulating bodies into clothing, dealing with fabrics and bodies which 'act back' and are resistant to the process of dressing. We consider how the materiality of clothing can constrain or enable practices of care, exploring tensions between garments that support ease of dressing and those that sustain identity. Examining negotiations around dress also reveals tensions between competing 'logics' of care (Mol ). © 2018 The Authors. Sociology of Health & Illness published by John Wiley & Sons Ltd on behalf of Foundation for SHIL.
Effect of periodontal dressings on human gingiva fibroblasts in vitro
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eber, R.M.; Shuler, C.F.; Buchanan, W.
1989-08-01
In vitro cytotoxicity studies of periodontal dressings have not generally produced a result consistent with in vivo observations. These prior in vitro studies have not used human intraoral cell lines. We tested the effects of two eugenol containing and two non-eugenol periodontal dressings on cultured human gingival fibroblasts (HGF) (ATCC No. 1292). Replicate HGF cultures grown in microtiter plates were exposed to stock, 1:4 and 1:16 dilutions of extracts made from each of the four periodontal dressings. The HGF cultures were pulse labelled with tritiated thymidine (3HTdR) after 24, 48, and 72 hours. Incorporations of the labelled thymidine were measuredmore » using liquid scintillation counting and expressed as counts per minute. The results showed that undiluted extracts from all four periodontal dressings totally inhibited 3HTdR uptake (P less than 0.05). The 1:4 dilution of eugenol dressings inhibited 3HTdR uptake significantly more than non-eugenol dressings (P less than 0.05). Interestingly, at 72 hours the 1:16 dilution of the non-eugenol dressings caused significantly increased 3HTdR uptake which was not observed with the eugenol dressings. The present results suggest that the use of a human fibroblastic cell line for testing the effects of periodontal dressings may provide information about the relative biological effects of these dressings. Using this cell line, we have found that eugenol dressings inhibit fibroblast proliferation to a greater extent than non-eugenol dressings.« less
MORE EVIDENCE THAT VOYAGER 1 IS STILL IN THE HELIOSPHERE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gloeckler, G.; Fisk, L. A., E-mail: gglo@umich.edu
The investigators of the Voyager mission currently exploring the heliosheath have concluded and announced that Voyager 1 (V1) has crossed the heliopause and is now in the interstellar medium. This conclusion is based primarily on the plasma wave observations of Gurnett et al., which reveal a plasma electron density that resembles the density expected in the local interstellar medium. Fisk and Gloeckler have disputed the conclusion that V1 has crossed the heliopause, pointing out that to account for all the V1 observations, particularly the magnetic field direction together with the density, it is necessary to conclude that the higher densitiesmore » observed by Gurnett et al. are due to compressed solar wind. In this Letter it is shown that the model of Fisk and Gloeckler for the nose region of the heliosheath can account in detail for the intensity and spectral shape of Energetic Neutral Hydrogen observed by the Interstellar Boundary Explorer (IBEX) in the directions of V1 and Voyager 2 (V2). A key feature of the Fisk and Gloeckler model is the existence of a region in the heliosheath where the solar wind is compressed and heated, followed by a region where the solar wind is compressed but cold. The region of cold compressed solar wind provides a unique explanation for the low-energy IBEX observations, and since this is the region where V1 must now reside, the low-energy IBEX observations provide strong evidence that V1 is still in the heliosphere.« less
Mahoney, Diane Feeney; Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Mahoney, Edward Leo
2015-01-01
Background Prior research has critiqued the lack of attention to the stressors associated with dementia related dressing issues, stigmatizing patient clothing, and wearable technology challenges. This paper describes the conceptual development and feasibility testing of an innovative ‘smart dresser’ context aware affective system (DRESS) to enable dressing by people with moderate memory loss through individualized audio and visual task prompting in real time. Methods Mixed method feasibility study involving qualitative focus groups with 25 Alzheimer’s family caregivers experiencing dressing difficulties to iteratively inform system design and a quantitative usability trial with 10 healthy subjects in a controlled laboratory setting to assess validity of technical operations. Results Caregivers voiced the need for tangible dressing assistance to reduce their frustration from time spent in repetitive cueing and power struggles over dressing. They contributed 6 changes that influenced the prototype development, most notably adding a dresser top iPad to mimic a familiar ‘TV screen’ for the audio and visual cueing. DRESS demonstrated promising overall functionality, however the validity of identification of dressing status ranged from 0% for the correct pants dressing to 100% for all shirts dressing scenarios. Adjustments were made to the detection components of the system raising the accuracy of detection of all acted dressing scenarios for pants from 50% to 82%. Conclusions Findings demonstrate family caregiver acceptability of the proposed system, the successful interoperability of the built system’s components, and the system’s ability to interpret correct and incorrect dressing actions in controlled laboratory simulations. Future research will advance the system to the alpha stage and subsequent testing with end users in real world settings. PMID:26321895
NASA Astrophysics Data System (ADS)
Elramady, Alyaa Gamal
The aim of this research project is to correlate the plastic deformation and mechanical instability of casing steel materials with corrosion behavior and surface change, in order to identify a tolerable degree of deformation for casing steel materials. While the corrosion of pipeline and casing steels has been investigated extensively, corrosion of these steels in sweet environments with respect to plastic deformation due to bending, rolling, autofrettage, or handling needs more investigation. Downhole tubular expansion of pipes (casings) is becoming standard practice in the petroleum industry to repair damaged casings, shutdown perforations, and ultimately achieve mono-diameter wells. Tubular expansion is a cold-drawing metal forming process, which consists of running conical mandrels through casings either mechanically using a piston or hydraulically by applying a back pressure. This mechanism subjects the pipes to large radial plastic deformations of up to 30 pct. of the inner diameter. It is known that cold-working is a way of strengthening materials such as low carbon steel, but given that this material will be subjected to corrosive environments, susceptibility to stress corrosion cracking (SCC) should be investigated. This research studies the effect of cold-work, in the form of cold-rolling and cold-expansion, on the surface behavior of API 5CT steels when it is exposed to a CO2-containing environment. Cold-work has a pronounced influence on the corrosion behavior of both API 5CT K55 and P110 grade steels. The lowest strength grade steel, API 5CT K55, performed poorly in a corrosive environment in the slow strain rate test. The ductile material exhibited the highest loss in strength and highest susceptibility to stress corrosion cracking in a CO 2-containing environment. The loss in strength declined with cold-rolling, which can be ascribed to the surface compressive stresses induced by cold-work. On the other hand, API 5CT P110 grade steels showed higher susceptibility to SCC when they were cold-rolled and cold-expanded. The research found that surface compressive stresses have an effect on the SCC behavior of casing and tubing steels. The CO2 corrosion behavior and atomic processes at the corroding interface were investigated at laboratory temperature using electrochemical techniques. Cold-work was found to have an influence on the corrosion behavior of both API 5CT K55 and P110 grade steels. These behaviors were found to be material and process dependent. Surface evaluation techniques such as field emission scanning electron microscope (FE-SEM) and X-ray diffraction (XRD) analysis did not detect formation of a protective scale. X-ray diffraction and X-ray photoelectron spectroscopy (XPS) analysis both detected the appearance of a scale that was traced back to magnetite.
21 CFR 169.115 - French dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false French dressing. 169.115 Section 169.115 Food and... § 169.115 French dressing. (a) Description. French dressing is the separable liquid food or the..., lecithin, or polyglycerol esters of fatty acids. (d) Nomenclature. The name of the food is “French dressing...
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L.; Carty, Neal; Johnson, Peter
2015-01-01
Background Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Methods Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. Results The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. Conclusion The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes. PMID:26599087
NASA Astrophysics Data System (ADS)
Aleksandrova, Irina
2016-01-01
The existing studies, concerning the dressing process, focus on the major influence of the dressing conditions on the grinding response variables. However, the choice of the dressing conditions is often made, based on the experience of the qualified staff or using data from reference books. The optimal dressing parameters, which are only valid for the particular methods and dressing and grinding conditions, are also used. The paper presents a methodology for optimization of the dressing parameters in cylindrical grinding. The generalized utility function has been chosen as an optimization parameter. It is a complex indicator determining the economic, dynamic and manufacturing characteristics of the grinding process. The developed methodology is implemented for the dressing of aluminium oxide grinding wheels by using experimental diamond roller dressers with different grit sizes made of medium- and high-strength synthetic diamonds type ??32 and ??80. To solve the optimization problem, a model of the generalized utility function is created which reflects the complex impact of dressing parameters. The model is built based on the results from the conducted complex study and modeling of the grinding wheel lifetime, cutting ability, production rate and cutting forces during grinding. They are closely related to the dressing conditions (dressing speed ratio, radial in-feed of the diamond roller dresser and dress-out time), the diamond roller dresser grit size/grinding wheel grit size ratio, the type of synthetic diamonds and the direction of dressing. Some dressing parameters are determined for which the generalized utility function has a maximum and which guarantee an optimum combination of the following: the lifetime and cutting ability of the abrasive wheels, the tangential cutting force magnitude and the production rate of the grinding process. The results obtained prove the possibility of control and optimization of grinding by selecting particular dressing parameters.
Forni, Cristiana; D'Alessandro, Fabio; Gambino, Orazio; Amodeo, Alfredo; Pignotti, Elettra; Zanotti, Enrichetta; Tremosini, Morena; Trofa, Carmela; Sabattini, Tania; Matino, Federica; Genco, Rossana; Schiavone, Miguel; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Capezzali, Daniela; Boschi, Rita; Loro, Loretta
2012-01-01
Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC), on the incidence of phlebitis. A randomized controlled trial. The type of dressing could contribute to the incidence of phlebitis, infiltration and accidental removals but the results of the studies are contrasting and samples are limited. To compare the effectiveness of a transparent polyurethane sterile dressing on the rate of phlebitis associated to peripheral venous catheter (PVC) vs a non sterile sticking plaster in use in current practice (standard dressing). Randomized controlled trial. Participants. 1061 PVCs (703 patients, adults and children) at a research orthopedic hospital in the north of Italy; 540 PVCs allocated to receive the sterile and 521 the standard dressing. 96 PVCs were excluded for phlebitis, 48 (9.6%) in the sterile and 48 (10.1%) in the standard dressing group, RR 0.96 (95%CI 0.697 - 1.335). Accidental removal of the PVCs was more frequent with the sterile dressing (9.6% vs 6.3%) but the number of catheters removed without complications was larger in the standard dressing group (48.9% vs 54.9% P=0.0503). Eighty-five PVCs were replaced for detachment of the dressing (50, 9.2% sterile and 35, 6.7% standard dressing). The cheapest transparent sterile dressing costs 32 cents while the standard 9 cents. A sticking non sterile plasters is not influential on the rate of phlebitis and ensures an good fix of the PVC compared the transparent sterile dressing to of polyurethane film.
A simple expression for the cold compression curve.
NASA Astrophysics Data System (ADS)
Čelebonović, V.
1996-10-01
The aim of this contribution is to present expressions for the bulk modulus of a material and its pressure derivative obtained by using the semi-classical theory of dense matter proposed by P. Savić and R. Kašanin. Some possibilities for the application of these expressions are briefly discussed.
Branched-chain fatty acid methyl esters as cold flow improvers for biodiesel
USDA-ARS?s Scientific Manuscript database
Biodiesel is an alternative diesel fuel derived mainly from the transesterification of plant oils with methanol or ethanol. This fuel is generally made from commodity oils such as canola, palm, or soybean and has a number of properties that make it compatible in compression-ignition engines. Despite...
Can non-adhesive short stretch bandages change a life?
Laginja, Stanislava; Seremet, Jasmina; Stiglić, Damir; Jancić, Ervin
2014-12-01
Venous stasis ulcers are common in patients who have a history of leg swelling, varicose veins, or a history of blood clots in either the superficial or the deep veins of their legs. The treatment is long and hard but the main aim of it is to create such an environment that allows skin to grow over an ulcer. Chronic wounds are a growing social, economical and health issue throughout the world. The purpose of this retrospective study was to establish detailed characterization of how effective a compression is in reducing the time of wound healing. A total of 176 patients with leg ulcers were included in our three years study. The measurements were taken based on the anamnesis, presenting clinical symptoms, digital photography at each dressing foam change, and, finally, wounds. During a 3 years period (2011-2013) a total of 176 patients (61 male and 115 female, 34.66% and 65.34% respectively) with different types of leg ulcers were treated at our Hospital. The average age is 68.94 years (male 68 years, female 70 years). We measured how long the patient had the wound before starting the treatment, and also how long the treatment lasted. This led us to the conclusion that compression therapy shortened the time of treatment by two thirds, compared to the usual therapy. Compression systems improve the healing of venous leg ulcers and should be used routinely regarding venous ulcers.
Nanofibrillar cellulose wound dressing in skin graft donor site treatment.
Hakkarainen, T; Koivuniemi, R; Kosonen, M; Escobedo-Lucea, C; Sanz-Garcia, A; Vuola, J; Valtonen, J; Tammela, P; Mäkitie, A; Luukko, K; Yliperttula, M; Kavola, H
2016-12-28
Although new therapeutic approaches for burn treatment have made progress, there is still need for better methods to enhance wound healing and recovery especially in severely burned patients. Nanofibrillar cellulose (NFC) has gained attention due to its renewable nature, good biocompatibility and excellent physical properties that are of importance for a range of applications in pharmaceutical and biomedical fields. In the present study, we investigated the potential of a wood based NFC wound dressing in a clinical trial on burn patients. Previously, we have investigated NFC as a topical functionalized wound dressing that contributes to improve wound healing in mice. Wood based NFC wound dressing was tested in split-thickness skin graft donor site treatment for nine burn patients in clinical trials at Helsinki Burn Centre. NFC dressing was applied to split thickness skin graft donor sites. The dressing gradually dehydrated and attached to donor site during the first days. During the clinical trials, physical and mechanical properties of NFC wound dressing were optimized by changing its composition. From patient 5 forward, NFC dressing was compared to commercial lactocapromer dressing, Suprathel® (PMI Polymedics, Germany). Epithelialization of the NFC dressing-covered donor site was faster in comparison to Suprathel®. Healthy epithelialized skin was revealed under the detached NFC dressing. NFC dressing self-detached after 11-21days for patients 1-9, while Suprathel® self-detached after 16-28days for patients 5-9. In comparison studies with patients 5-9, NFC dressing self-detached on average 4days earlier compared with Suprathel®. Lower NFC content in the material was evaluated to influence the enhanced pliability of the dressing and attachment to the wound bed. No allergic reaction or inflammatory response to NFC was observed. NFC dressing did not cause more pain for patients than the traditional methods to treat the skin graft donor sites. Based on the preliminary clinical data, NFC dressing seems to be promising for skin graft donor site treatment since it is biocompatible, attaches easily to wound bed, and remains in place until donor site has renewed. It also detaches from the epithelialized skin by itself. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Timsit, Jean-François; Mimoz, Olivier; Mourvillier, Bruno; Souweine, Bertrand; Garrouste-Orgeas, Maïté; Alfandari, Serge; Plantefeve, Gaétan; Bronchard, Régis; Troche, Gilles; Gauzit, Remy; Antona, Marion; Canet, Emmanuel; Bohe, Julien; Lepape, Alain; Vesin, Aurélien; Arrault, Xavier; Schwebel, Carole; Adrie, Christophe; Zahar, Jean-Ralph; Ruckly, Stéphane; Tournegros, Caroline; Lucet, Jean-Christophe
2012-12-15
Most vascular catheter-related infections (CRIs) occur extraluminally in patients in the intensive care unit (ICU). Chlorhexidine-impregnated and strongly adherent dressings may decrease catheter colonization and CRI rates. To determine if chlorhexidine-impregnated and strongly adherent dressings decrease catheter colonization and CRI rates. In a 2:1:1 assessor-masked randomized trial in patients with vascular catheters inserted for an expected duration of 48 hours or more in 12 French ICUs, we compared chlorhexidine dressings, highly adhesive dressings, and standard dressings from May 2010 to July 2011. Coprimary endpoints were major CRI with or without catheter-related bloodstream infection (CR-BSI) with chlorhexidine versus nonchlorhexidine dressings and catheter colonization rate with highly adhesive nonchlorhexidine versus standard nonchlorhexidine dressings. Catheter-colonization, CR-BSIs, and skin reactions were secondary endpoints. A total of 1,879 patients (4,163 catheters and 34,339 catheter-days) were evaluated. With chlorhexidine dressings, the major-CRI rate was 67% lower (0.7 per 1,000 vs. 2.1 per 1,000 catheter-days; hazard ratio [HR], 0.328; 95% confidence interval [CI], 0.174-0.619; P = 0.0006) and the CR-BSI rate 60% lower (0.5 per 1,000 vs. 1.3 per 1,000 catheter-days; HR, 0.402; 95% CI, 0.186-0.868; P = 0.02) than with nonchlorhexidine dressings; decreases were noted in catheter colonization and skin colonization rates at catheter removal. The contact dermatitis rate was 1.1% with and 0.29% without chlorhexidine. Highly adhesive dressings decreased the detachment rate to 64.3% versus 71.9% (P < 0.0001) and the number of dressings per catheter to two (one to four) versus three (one to five) (P < 0.0001) but increased skin colonization (P < 0.0001) and catheter colonization (HR, 1.650; 95% CI, 1.21-2.26; P = 0.0016) without influencing CRI or CR-BSI rates. A large randomized trial demonstrated that chlorhexidine-gel-impregnated dressings decreased the CRI rate in patients in the ICU with intravascular catheters. Highly adhesive dressings decreased dressing detachment but increased skin and catheter colonization. Clinical trial registered with www.clinicaltrials.gov (NCT 01189682).
NASA Astrophysics Data System (ADS)
Kampeerapappun, Piyaporn
In general, a dressing is used to protect and help heal wounds. There are several types of dressings on the market such as hydrocolloid, hydrogel, and medicated dressings. One technique for making a dressing is electrospinning, which is a very simple procedure used to produce fibers. Due to much smaller fiber-diameters than produced with the conventional technique, the fibers from electrospinning have unique properties: high porosity and high surface areas, which are advantageous for wound healing. In this research, the fibers were electrospun using polyurethane, TecophilicRTM or TecoflexRTM, with various additives. First, multilayer transdermal electrospun dressings, four and five-layers, were developed that allowed for the controlled release of nitric oxide (NO) from a NO2 -/ascorbic acid system encapsulated in polymer nanofibers. The amount of NO released from each wound dressing was investigated. Both the four and five-layer dressings were tested for morphology of fibers, water absorption, nitrite distribution, NO release profile after sterilization by gamma radiation, and stability. In the case of the four-layer transdermal dressing, the dressing was tested in diabetic, periodontal, and cutaneous leishmaniasis patients. Furthermore, the color change of dressing was investigated. TecophilicRTM was also spun with an antimicrobial agent, which was added to the TecophilicRTM solution to electrospin an antimicrobial dressing. The morphology of fibers was tested using an optical microscope and the water absorption, uniformity, and percent extraction of dressing were also determined. In addition, the efficiency of the antimicrobial agent in the dressing was determined according to SN 195920-1994 and ASTM 2149-01. Another NO-releasing dressing was developed employing the NO donor molecules, sodium salt of linear polyethylenimine NONOates (LPEINO-Na) and calcium salt of linear polyethylenimine NONOates (LPEINO-Ca), which were electrospun with TecophilicRTM. The NO release profiles for the LPEINO fibers were generated using a nitric oxide analyzer (NOA) and distribution of the particles in the dressing was examined. Moreover, the amount of NO released after patch storage for 1 and 2 months was determined.
Heterogeneous multi-layered IF steel with simultaneous high strength and good ductility
NASA Astrophysics Data System (ADS)
Zhang, Ling; Jiang, Xiaojuan; Wang, Yuhui; Chen, Qiang; Chen, Zhen; Zhang, Yonghong; Huang, Tianlin; Wu, Guilin
2017-07-01
Multi-layered IF steel samples were designed and fabricated by hot compression followed by cold forging of an alternating stack of cold-rolled and annealed IF steel sheets, with an aim to improve the strength of the material without losing much ductility. A very good combination of strength and ductility was achieved by proper annealing after deformation. Microstructural analysis by electron back-scatter diffraction revealed that the good combination of strength and ductility is related to a characteristic hierarchical structure that is characterized by layered and lamella structures with different length scales.
Shock compression response of cold-rolled Ni/Al multilayer composites
NASA Astrophysics Data System (ADS)
Specht, Paul E.; Weihs, Timothy P.; Thadhani, Naresh N.
2017-01-01
Uniaxial strain, plate-on-plate impact experiments were performed on cold-rolled Ni/Al multilayer composites and the resulting Hugoniot was determined through time-resolved measurements combined with impedance matching. The experimental Hugoniot agreed with that previously predicted by two dimensional (2D) meso-scale calculations [Specht et al., J. Appl. Phys. 111, 073527 (2012)]. Additional 2D meso-scale simulations were performed using the same computational method as the prior study to reproduce the experimentally measured free surface velocities and stress profiles. These simulations accurately replicated the experimental profiles, providing additional validation for the previous computational work.
... as much gauze or packing gauze. Removing the Old Dressing Follow these steps to remove your dressing: ... sterile gloves. Carefully remove the tape. Remove the old dressing. If it is sticking to your skin, ...
Evaluation of a foam dressing for acute and chronic wound exudate management.
Bullough, Lindsay; Johnson, Sue; Forder, Rebecca
2015-09-01
This article discusses the use of a foam dressing for exudate management in both chronic and acute wounds, such as surgical wounds, pressure ulcers, diabetic ulcers, trauma wounds, and leg ulcers. The primary objective of the study was to observe patients' wound progression in terms of wound size and the condition of the wound bed, when using this foam dressing as either a primary or secondary dressing. The outcome of the evaluation demonstrated that ActivHeal Foam Contact dressing effectively managed exudate. It was also observed that the dressing can assist in autolysis and support improvements in peri-wound status. Choosing an appropriate dressing to manage a wound is essential. Clinicians working in the NHS are under pressure to deliver good-quality clinical outcomes, and the ActivHeal Foam Contact dressing supports this outcome.
Ice/water slurry blocking phenomenon at a tube orifice.
Hirochi, Takero; Yamada, Shuichi; Shintate, Tuyoshi; Shirakashi, Masataka
2002-10-01
The phenomenon of ice-particle/water mixture blocking flow through a pipeline is a problem that needs to be solved before mixture flow can be applied for practical use in cold energy transportation in a district cooling system. In this work, the blocking mechanism of ice-particle slurry at a tube orifice is investigated and a criterion for blocking is presented. The cohesive nature of ice particles is shown to cause compressed plug type blocking and the compressive yield stress of a particle cluster is presented as a measure for the cohesion strength of ice particles.
High-power ultrashort fiber laser for solar cells micromachining
NASA Astrophysics Data System (ADS)
Lecourt, J.-B.; Duterte, C.; Liegeois, F.; Lekime, D.; Hernandez, Y.; Giannone, D.
2012-02-01
We report on a high-power ultra-short fiber laser for thin film solar cells micromachining. The laser is based on Chirped Pulse Amplification (CPA) scheme. The pulses are stretched to hundreds of picoseconds prior to amplification and can be compressed down to picosecond at high energy. The repetition rate is adjustable from 100 kHz to 1 MHz and the optical average output power is close to 13 W (before compression). The whole setup is fully fibred, except the compressor achieved with bulk gratings, resulting on a compact and reliable solution for cold ablation.
Nonpainful wide-area compression inhibits experimental pain.
Honigman, Liat; Bar-Bachar, Ofrit; Yarnitsky, David; Sprecher, Elliot; Granovsky, Yelena
2016-09-01
Compression therapy, a well-recognized treatment for lymphoedema and venous disorders, pressurizes limbs and generates massive non-noxious afferent sensory barrages. The aim of this study was to study whether such afferent activity has an analgesic effect when applied on the lower limbs, hypothesizing that larger compression areas will induce stronger analgesic effects, and whether this effect correlates with conditioned pain modulation (CPM). Thirty young healthy subjects received painful heat and pressure stimuli (47°C for 30 seconds, forearm; 300 kPa for 15 seconds, wrist) before and during 3 compression protocols of either SMALL (up to ankles), MEDIUM (up to knees), or LARGE (up to hips) compression areas. Conditioned pain modulation (heat pain conditioned by noxious cold water) was tested before and after each compression protocol. The LARGE protocol induced more analgesia for heat than the SMALL protocol (P < 0.001). The analgesic effect interacted with gender (P = 0.015). The LARGE protocol was more efficient for females, whereas the MEDIUM protocol was more efficient for males. Pressure pain was reduced by all protocols (P < 0.001) with no differences between protocols and no gender effect. Conditioned pain modulation was more efficient than the compression-induced analgesia. For the LARGE protocol, precompression CPM efficiency positively correlated with compression-induced analgesia. Large body area compression exerts an area-dependent analgesic effect on experimental pain stimuli. The observed correlation with pain inhibition in response to robust non-noxious sensory stimulation may suggest that compression therapy shares similar mechanisms with inhibitory pain modulation assessed through CPM.
Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-05-01
Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). This laboratory study evaluated the DRESS prototype's capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing-typical issues that challenge a PWD and their caregivers. A set of expected detections for correct dressing was prepared via video analysis of all participants' dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype's ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype's reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. ©Winslow Burleson, Cecil Lozano, Vijay Ravishankar, Jisoo Lee, Diane Mahoney. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 01.05.2018.
Evaluation of dressings used with local anaesthetic cream and for peripheral venous cannulation.
Needham, Rowan; Strehle, Eugen-Matthias
2008-10-01
To compare four polyurethane dressings manufactured by two different companies for use in children. Seventy-eight dressings were applied to secure either local anaesthetic creams (n = 62) or intravenous cannulae (n = 16). Each dressing was evaluated for ease of application, security and ease of removal, using a simple scoring system. 84 per cent of Opsite flexigrid and 90 per cent of Tegaderm local anaesthetic cream dressings were rated as easy or very easy to apply. Opsite flexigrid was felt to be more secure, whereas Tegaderm was easier to remove. The Tegaderm cannula dressing was easier to apply than the iv3000 dressing. There was little difference between the two brands, including costs.
Deep Subducction in a Compressible Mantle: Observations and Theory
NASA Astrophysics Data System (ADS)
King, S. D.
2017-12-01
Our understanding of slab dynamics is primarily based on the results of numerical models of subduction. In such models coherent, cold slabs are clearly visible from the surface of the Earth to the core mantle boundary. In contrast, fast seismic anomalies associated with cold subducted slabs are difficult to identify below 1500-2000 km in tomographic models of Earth's mantle. One explanation for this has been the resolution, or lack thereof, of seismic tomography in the mid-mantle region; however in this work I will explore the impact of compressibility on the dynamics of subducting slabs, specifically shear heating of the slab and latent heat of phase transformations. Most geodynamic models of subduction have used an incompressible formulation, thus because subducted slabs are assumed to be cold and stiff, the primary means of thermal equilibration is conduction. With an assumed sinking velocity of approximately 0.1 m/yr, a subducted slab reaches the core-mantle boundary in approximately 30 Myrs—too fast for significant conductive cooling of the downgoing slab. In this work I consider a whole-mantle geometry and include both phase transformations with associated latent heat and density changes from the olivine-wadsleyite-ringwoodite-bridgmanite system and the pyroxene-garnet system. The goal of this work is to understand both the eventual fate and thermal evolution of slabs beneath the transition zone.
ERIC Educational Resources Information Center
Griffiths, Noola K.
2010-01-01
This study investigates the effects of concert dress and physical appearance on perceptions of female classical soloists' musical abilities over a range of genres. Four female violinists were recorded playing three pieces, in four styles of dress of varying formality. Each combination of performer, piece and dress was recorded twice, once as the…
Use of wound dressings with soft silicone adhesive technology.
Morris, Clare; Emsley, Paulene; Marland, Elizabeth; Meuleneire, Frans; White, Richard
2009-04-01
To evaluate how pain, during and in-between dressing changes, is affected by the introduction of Mepilex Border Lite, a wound dressing manufactured by Mölnlycke Health Care using Safetac soft silicone adhesive technology, to the treatment of different types of paediatric wounds/skin injuries. Wounds/skin injuries that met the criteria for inclusion in the study were dressed with Mepilex Border Lite. Patients were followed for six weeks or until their wounds/skin injuries had healed, whichever occurred earlier. At each dressing change, pain severity before and during dressing removal was rated by the patient and the investigator on a scale from zero (no pain at all) to ten (worst pain ever). Other variables measured included: signs of trauma to wound/skin injury and surrounding skin, the proportion of viable/non-viable tissue, the quantity and appearance of exudate, odour, and clinical signs of infection. At the final dressing change, patients and investigators completed questionnaires to rate the dressing performance. Mean pain severity scores were significantly lower (p < or = 0.003) at the first dressing change than at baseline. Over 99.5 per cent of the Mepilex Border Lite dressing changes were reported to be atraumatic and more than half of the wounds healed within the study period. Conformability, ease of use, ease of removal, patient comfort, and overall experience with the dressing were rated as 'good' to 'very good' at the vast majority of final visit evaluations. This study provides further evidence of the ability of dressings with Safetac soft silicone adhesive technology to minimise trauma and pain and demonstrates the ability of Mepilex Border Lite to overcome the clinical challenges associated with the use of dressings on the wounds/skin injuries of paediatric patients.
Zehrer, Cindy L; Holm, David; Solfest, Staci E; Walters, Shelley-Ann
2014-12-01
This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghosh, S. S., E-mail: sukti@iigs.iigm.res.in; Sekar Iyengar, A. N.
It is observed that the presence of a minority component of cooler electrons in a three component plasma plays a deterministic role in the evolution of solitary waves, double layers, or the newly discovered structures called supersolitons. The inclusion of the cooler component of electrons in a single electron plasma produces sharp increase in nonlinearity in spite of a decrease in the overall energy of the system. The effect maximizes at certain critical value of the number density of the cooler component (typically 15%–20%) giving rise to a hump in the amplitude variation profile. For larger amplitudes, the hump leadsmore » to a forbidden region in the ambient cooler electron concentration which dissociates the overall existence domain of solitary wave solutions in two distinct parameter regime. It is observed that an inclusion of the cooler component of electrons as low as < 1% affects the plasma system significantly resulting in compressive double layers. The solution is further affected by the cold to hot electron temperature ratio. In an adequately hotter bulk plasma (i.e., moderately low cold to hot electron temperature ratio), the parameter domain of compressive double layers is bounded by a sharp discontinuity in the corresponding amplitude variation profile which may lead to supersolitons.« less
Napavichayanun, Supamas; Yamdech, Rungnapha; Aramwit, Pornanong
2016-03-01
In our previous work, we have attempted to develop a novel bacterial nanocellulose wound dressing which composed of both polyhexamethylene biguanide (PHMB) as an antimicrobial agent and sericin as an accelerative wound healing component. The loading sequence and concentration of PHMB and sericin were optimized to provide the wound dressing with the most effective antimicrobial activity and enhanced collagen production. In this study, further in vitro, in vivo, and clinical studies of this novel wound dressing were performed to evaluate its safety, efficacy, and applicability. For the in vitro cytotoxic test with L929 mouse fibroblast cells, our novel dressing was not toxic to the cells and also promoted cell migration as good as the commercially available dressing, possibly due to the component of sericin released. When implanted subcutaneously in rats, the lower inflammation response was observed for the novel dressing implanted, comparing to the commercially available dressing. This might be that the antimicrobial PHMB component of the novel dressing played a role to reduce infection and inflammation reaction. The clinical trial patch test was performed on the normal skin of healthy volunteers to evaluate the irritation effect of the dressing. Our novel dressing did not irritate the skin of any volunteers, as characterized by the normal levels of erythema and melanin and the absence of edema, papule, vesicle, and bullae. Then, the novel dressing was applied for the treatment of full-thickness wounds in rats. The wounds treated with our novel dressing showed significantly lower percentage of wound size and higher extent of collagen formation mainly due to the activity of sericin. We concluded that our novel bacterial nanocellulose incorporating PHMB and sericin was a safe and efficient wound dressing material for further investigation in the wound healing efficacy in clinic.
Dressing the post-Newtonian two-body problem and classical effective field theory
NASA Astrophysics Data System (ADS)
Kol, Barak; Smolkin, Michael
2009-12-01
We apply a dressed perturbation theory to better organize and economize the computation of high orders of the 2-body effective action of an inspiralling post-Newtonian (PN) gravitating binary. We use the effective field theory approach with the nonrelativistic field decomposition (NRG fields). For that purpose we develop quite generally the dressing theory of a nonlinear classical field theory coupled to pointlike sources. We introduce dressed charges and propagators, but unlike the quantum theory there are no dressed bulk vertices. The dressed quantities are found to obey recursive integral equations which succinctly encode parts of the diagrammatic expansion, and are the classical version of the Schwinger-Dyson equations. Actually, the classical equations are somewhat stronger since they involve only finitely many quantities, unlike the quantum theory. Classical diagrams are shown to factorize exactly when they contain nonlinear worldline vertices, and we classify all the possible topologies of irreducible diagrams for low loop numbers. We apply the dressing program to our post-Newtonian case of interest. The dressed charges consist of the dressed energy-momentum tensor after a nonrelativistic decomposition, and we compute all dressed charges (in the harmonic gauge) appearing up to 2PN in the 2-body effective action (and more). We determine the irreducible skeleton diagrams up to 3PN and we employ the dressed charges to compute several terms beyond 2PN.
Cost of dressings for prevention of sacral pressure ulcers.
Inoue, Kelly Cristina; Matsuda, Laura Misue
2016-01-01
to identify costs of dressings to prevent sacral pressure ulcers in an adult intensive care unit in Paraná, Brazil. secondary analysis study with 25 patients admitted between October 2013 and March 2014, using transparent polyurethane film (n=15) or hydrocolloid dressing (n=10) on the sacral region. The cost of each intervention was based on the unit amount used in each type of dressing, and its purchase price (transparent film = R$15.80, hydrocolloid dressing = R$68.00). the mean cost/patient was R$23.17 for use of transparent film and R$190.40 for use of hydrocolloid dressing. The main reason for changing the dressing was detachment. the transparent film was the most economically advantageous alternative to prevent sacral pressure ulcers in critical care patients. However, additional studies should be carried out including assessment of the effectiveness of both dressings.
Genuino, Glenn Angelo S; Baluyut-Angeles, Kathrina Victoria; Espiritu, Andre Paolo T; Lapitan, Marie Carmela M; Buckley, Brian S
2014-11-01
Non-extensive superficial partial thickness burns constitute a major proportion of burns. Conventional treatment involves regular changing of absorptive dressings including the application of a topical antimicrobial, commonly silver sulfadiazine. A systematic review has found insufficient evidence to support or refute such antimicrobial prophylaxis. Another review compared silver sulfadiazine dressings with other occlusive and non-antimicrobial dressings and found insufficient evidence to guide practice. Other research has suggested that dressings with petrolatum gel are as effective as silver sulfadiazine. Single-center, randomized, controlled parallel group trial comparing conventional silver sulfadiazine dressings with treatment with petrolatum gel alone. Consenting adults 18-45 years old with superficial partial thickness burns≤10% total body surface area seen within 24h of the injury were randomized to daily dressing either with petrolatum gel without top dressings or conventional silver sulfadiazine treatment with gauze dressings. Primary outcomes were blinded assessment of time to complete re-epithelialization, wound infection or allergic contact dermatitis. Secondary outcomes included assessment of ease, time and pain of dressing changes. 26 patients were randomized to petrolatum and 24 to silver sulfadiazine dressings. Follow up data available for 19 in each group. Mean time to re-epithelialization was 6.2 days (SD 2.8) in the petrolatum group and 7.8 days (SD 2.1) in the silver sulfadiazine group (p=0.050). No wound infection or dermatitis was observed in either group. Scores for adherence to wound, ease of dressing removal and time required to change dressings were significantly better in the petrolatum treatment arm (p<0.01). Petrolatum gel without top dressings may be at least as effective as silver sulfadiazine gauze dressings with regard to time to re-epithelialization, and incidence of infection and allergic contact dermatitis. Petrolatum gel appears to be an effective, affordable and widely available alternative in the treatment of minor superficial partial thickness burns in adults. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Kent, Dea J
2010-01-01
I compared the effects of a just-in-time educational intervention (educational materials for dressing application attached to the manufacturer's dressing package) to traditional wound care education on reported confidence and dressing application in a simulated model. Nurses from a variety of backgrounds were recruited for this study. The nurses possessed all levels of education ranging from licensed practical nurse to master of science in nursing. Both novice and seasoned nurses were included, with no stipulations regarding years of nursing experience. Exclusion criteria included nurses who spent less than 50% of their time in direct patient care and nurses with advanced wound care training and/or certification (CWOCN, CWON). Study settings included community-based acute care facilities, critical access hospitals, long-term care facilities, long-term acute care facilities, and home care agencies. No level 1 trauma centers were included in the study for geographical reasons. Participants were randomly allocated to control or intervention groups. Each participant completed the Kent Dressing Confidence Assessment tool. Subjects were then asked to apply the dressing to a wound model under the observation of either the principal investigator or a trained observer, who scored the accuracy of dressing application according to established criteria. None of the 139 nurses who received traditional dressing packaging were able to apply the dressing to a wound model correctly. In contrast, 88% of the nurses who received the package with the educational guide attached to it were able to apply the dressing to a wound model correctly (χ2 = 107.22, df = 1, P = .0001). Nurses who received the dressing package with the attached educational guide agreed that this feature gave them confidence to correctly apply the dressing (88%), while no nurse agreed that the traditional package gave him or her the confidence to apply the dressing correctly (χ2 = 147.47, df = 4, P < .0001). A just-in-time education intervention improved nurses' confidence when applying an unfamiliar dressing and accuracy of application when applying the dressing to a simulated model compared to traditional wound care education.
Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations.
Wu, Stephanie; Applewhite, Andrew J; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry
2017-11-01
Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. A 2-day panel meeting convened in February 2017. Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed.
Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations
Wu, Stephanie; Applewhite, Andrew J.; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry
2017-01-01
ABSTRACT OBJECTIVE: Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. DESIGN: A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. SETTING: A 2-day panel meeting convened in February 2017. PARTICIPANTS: Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. RESULTS: The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. CONCLUSIONS: An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed. PMID:29049055
Economics of pressure-ulcer care: review of the literature on modern versus traditional dressings.
San Miguel, L; Torra i Bou, J E; Verdú Soriano, J
2007-01-01
Published evidence suggests that some of the benefits of modern dressings--longer wear times and less frequent dressing changes--make them more cost-effective than traditional gauze dressings in pressure ulcer management.
Watson, Denis; Bergquist, Stephen; Nicholson, Julie; Norrie, David H
2017-06-28
While Manuka honey in vitro is strongly antimicrobial, there have been, to the best of the authors' knowledge, no studies showing that dressings impregnated with Manuka honey can kill organisms in the dressing itself. The investigators used the American Association of Textile Chemists and Colorists' 100 test methodology to compare honey-impregnated dressings with control dressings (without honey) on the ability to kill common wound pathogens. Organisms were chosen after a review of the causal organisms found in actual wound infections over a 12-month period in a busy outpatient wound clinic. Even when the dressings were challenged daily with further inoculated organisms, > 5-log reductions were routinely noted across a range of pathogens, including multiple drug-resistant species using dressings containing Manuka honey relative to the control. The results presented herein show that when well-characterized medical-grade Manuka honey is used in dressings (ie, a minimum of 400 mg methylglyoxal/kg) these dressings can comprehensively kill common wound pathogens associated with infected wounds.
Henriksson, Otto; Lundgren, Peter; Kuklane, Kalev; Holmér, Ingvar; Naredi, Peter; Bjornstig, Ulf
2012-02-01
In the prehospital care of a cold and wet person, early application of adequate insulation is of utmost importance to reduce cold stress, limit body core cooling, and prevent deterioration of the patient's condition. Most prehospital guidelines on protection against cold recommend the removal of wet clothing prior to insulation, and some also recommend the use of a waterproof vapor barrier to reduce evaporative heat loss. However, there is little scientific evidence of the effectiveness of these measures. Using a thermal manikin with wet clothing, this study was conducted to determine the effect of wet clothing removal or the addition of a vapor barrier on thermal insulation and evaporative heat loss using different amounts of insulation in both warm and cold ambient conditions. A thermal manikin dressed in wet clothing was set up in accordance with the European Standard for assessing requirements of sleeping bags, modified for wet heat loss determination, and the climatic chamber was set to -15 degrees Celsius (°C) for cold conditions and +10°C for warm conditions. Three different insulation ensembles, one, two or seven woollen blankets, were chosen to provide different levels of insulation. Five different test conditions were evaluated for all three levels of insulation ensembles: (1) dry underwear; (2) dry underwear with a vapor barrier; (3) wet underwear; (4) wet underwear with a vapor barrier; and (5) no underwear. Dry and wet heat loss and thermal resistance were determined from continuous monitoring of ambient air temperature, manikin surface temperature, heat flux and evaporative mass loss rate. Independent of insulation thickness or ambient temperature, the removal of wet clothing or the addition of a vapor barrier resulted in a reduction in total heat loss of 19-42%. The absolute heat loss reduction was greater, however, and thus clinically more important in cold environments when little insulation is available. A similar reduction in total heat loss was also achieved by increasing the insulation from one to two blankets or from two to seven blankets. Wet clothing removal or the addition of a vapor barrier effectively reduced evaporative heat loss and might thus be of great importance in prehospital rescue scenarios in cold environments with limited insulation available, such as in mass-casualty situations or during protracted evacuations in harsh conditions.
Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-01-01
Background Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. Objective In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). Methods This laboratory study evaluated the DRESS prototype’s capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing—typical issues that challenge a PWD and their caregivers. Results A set of expected detections for correct dressing was prepared via video analysis of all participants’ dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype’s ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype’s reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. Conclusions This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. PMID:29716885
Effects of adhesive dressings on stratum corneum conductance.
Cavallini, Maurizio; Gazzola, Riccardo; Vaienti, Luca
2012-05-01
Stratum corneum is a fundamental layer of epidermis. It acts as a barrier, with antimicrobial features, regulating skin permeability and integrity as well. Adhesive dressings and their removal could alter this layer, affecting cutaneous water balance and lipid composition of stratum corneum. These changes could be monitored by measurement of cutaneous hydration. Ninety-two patients affected by wounds dressed with adhesive tapes or plasters have been studied. Measurement of skin conductance under tape/plaster and in the surrounding healthy skin, immediately after removal of dressing has been performed. Dressing age, wound localization, and characteristics were also considered. Adhesive dressings alter significantly stratum corneum conductance. Although healthy skin hydration has significant variations throughout the body, cutaneous conductance under adhesive dressing in different areas displays no significative changes. Moreover, the increase in hydration due to adhesive tapes/plasters showed no association with wound dehiscence. Adhesive dressings cause a significative increase in stratum corneum conductance, acting as a barrier to apocrine secretions. Although different hydration levels have been observed in healthy skin throughout the body, no difference exists under adhesive dressing among different regions, suggesting no contraindications in their employment throughout the body. Increase in cutaneous hydration showed no correlations with wound dehiscence, thus confirming safety and practicality of these dressings. © 2011 John Wiley & Sons A/S.
Percy, Dean B; Haddock, Candace; Ma, Vivian; Nowak, Amie; Panczuk, Julia; Butterworth, Sonia
2018-05-01
The purpose of this study was to describe outcomes and resource utilization in patients treated with twice-weekly silver impregnated (SI) nanocrystalline dressings for initial non-operative management of giant omphalocele (GO). A retrospective review of patients with GO treated with SI dressings was undertaken. Clinical parameters, cost, and complications were recorded. Five patients with GO were treated with SI dressings between 2014 and 2016. Clinical characteristic (mean ± SD) included gestational age 36 ± 4 weeks, birth weight 2.6 ± 0.63 kg, GO size 10.2 ± 4.7 cm, ventilator days 7.5 ± 8.7 d, days in NICU 41 ± 20 d, days to full feeds, 30 ± 15 d, and LOS 62 ± 41 d. The average in-hospital cost of SI dressings was $110 CAD/week. This is comparable to daily silver sulfadiazine dressings ($109CAD/week) which were used historically. All patients were discharged with once- or twice-weekly dressing changes. No ruptures occurred. There was one mortality secondary to pulmonary sepsis. For initial non-operative management of GO, twice weekly SI nanocrystalline dressings is safe and effective. Use of SI dressings results in decreased handling of infants, reduced physician and nursing resource utilization, and favourable outcomes. IV (Retrospective Case Series). Copyright © 2018. Published by Elsevier Inc.
Janata, Andreas; Weihs, Wolfgang; Schratter, Alexandra; Bayegan, Keywan; Holzer, Michael; Frossard, Martin; Sipos, Wolfgang; Springler, Gregor; Schmidt, Peter; Sterz, Fritz; Losert, Udo M; Laggner, Anton N; Kochanek, Patrick M; Behringer, Wilhelm
2010-08-01
The induction of deep cerebral hypothermia via ice-cold saline aortic flush during prolonged ventricular fibrillation cardiac arrest, followed by hypothermic stasis and delayed resuscitation (emergency preservation and resuscitation), improved neurologic outcome after cardiac arrest in pigs, as compared to conventional resuscitation. We hypothesized that emergency preservation and resuscitation with chest compressions would further improve outcome in the same model. Prospective experimental study. University research laboratory. : Twenty-four female, large, white breed pigs (27-37 kg). Fifteen minutes of ventricular fibrillation cardiac arrest were followed by 20 mins of resuscitation with chest compressions (control, n = 8), deep cerebral hypothermia via 200 mL/kg 4 degrees C saline aortic flush and hypothermic stasis (emergency preservation and resuscitation, n = 8), and emergency preservation and resuscitation combined with chest compressions (emergency preservation and resuscitation plus chest compressions, n = 8). At 35 mins after cardiac arrest, cardiopulmonary bypass was initiated, followed by defibrillation. Mild hypothermia was continued for 20 hrs. Pigs were evaluated after 9 days using a neurologic deficit (neurologic deficit score: 100% = brain dead; 0%-10% = normal) and an overall performance category score (overall performance category score: 1 = normal; 2 = slightly handicapped; 3 = severely handicapped; 4 = comatose; 5 = dead/brain dead). Brain temperature decreased from 38.5 degrees C to 15.3 degrees C +/- 3.3 degrees C in the emergency preservation and resuscitation group, and to 11.3 degrees C +/- 1.2 degrees C in the emergency preservation and resuscitation plus chest compressions group. In the control group, restoration of spontaneous circulation was achieved in four out of eight pigs, and one survived to 9 days. In the emergency preservation and resuscitation group, restoration of spontaneous circulation was achieved in seven out of eight pigs and five survived; in the emergency preservation and resuscitation plus chest compressions group, all had restoration of spontaneous circulation and seven survived (restoration of spontaneous circulation, p = .08). Neurologic outcome for (median and interquartile range) the control group included overall performance category score of 3, neurologic deficit score of 45%; for the emergency preservation and resuscitation group, overall performance category score was 3 (2-5) and neurologic deficit score was 45% (36; 50) and in the emergency preservation and resuscitation plus chest compressions group, overall performance category score was 2 (1-3) and neurologic deficit score was 13% (5; 21) (overall performance category score, p = .04; neurologic deficit score emergency preservation and resuscitation vs. emergency preservation and resuscitation plus chest compressions, p = .003). Emergency preservation and resuscitation by deep cerebral hypothermia combined with chest compressions during prolonged cardiac arrest in pigs are feasible and improve neurologic outcome.
Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects
NASA Astrophysics Data System (ADS)
Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.
2006-04-01
Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.
Hua, Yun; Qiu, Rong; Yao, Wen-Yan; Zhang, Qin; Chen, Xiao-Li
2015-10-01
It has been demonstrated that patients with chronic wounds experience the most pain during dressing changes. Currently, researchers focus mostly on analgesics and appropriate dressing materials to relieve pain during dressing changes of chronic wounds. However, the effect of nonpharmacologic interventions, such as virtual reality distraction, on pain management during dressing changes of pediatric chronic wounds remains poorly understood. To investigate the effect of virtual reality distraction on alleviating pain during dressing changes in children with chronic wounds on their lower limbs. A prospective randomized study. A pediatric center in a tertiary hospital. Sixty-five children, aged from 4 to 16 years, with chronic wounds on their lower limbs. Pain and anxiety scores during dressing changes were recorded by using the Wong-Baker Faces picture scale, visual analogue scale, and pain behavior scale, as well as physiological measurements including pulse rate and oxygen saturation. Time length of dressing change was recorded. Virtual reality distraction significantly relieved pain and anxiety scores during dressing changes and reduced the time length for dressing changes as compared to standard distraction methods. The use of virtual reality as a distraction tool in a pediatric ward offered superior pain reduction to children as compared to standard distractions. This device can potentially improve clinical efficiency by reducing length time for dressing changes. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
High-strength bioresorbable Fe-Ag nanocomposite scaffolds: Processing and properties
NASA Astrophysics Data System (ADS)
Sharipova, Aliya; Psakhie, Sergey G.; Swain, Sanjaya K.; Gutmanas, Elazar Y.; Gotman, Irena
2015-10-01
High strength ductile iron-silver nanocomposite scaffolds were fabricated employing high energy attrition milling of micron-submicron powders, followed by cold sintering/high pressure consolidation. Particulate leaching method with soluble Na2SO4 and K2CO3 salts as porogens was used to create scaffolds with 50, 55, 60 and 73% volume fraction of pores. Part of specimens was annealed at 600, 800 and 900°C. Specimens were characterized employing X-ray diffraction, scanning electron microscopy (SEM) with electron probe microanalysis (EDS) and high resolution SEM. Mechanical properties were measured in compression and permeability was measured in permeameter based on Darcy's law. Scaffolds with 50% and 55% porosity exhibited high compressive strength (18-22 MPa), compressive strength of 8-12 MPa was observed for scaffolds with 73% porosity. Treatments at 800 and 900°C result in increase of strength and ductility with some coarsening of microstructure. Best combination of compressive strength (15 MPa) and permeability (0.6-6 cm2) is close to the range of trabecular bone.
An Inexpensive Bismuth-Petrolatum Dressing for Treatment of Burns
Chattopadhyay, Arhana; Chang, Kathleen; Nguyen, Khoa; Galvez, Michael G.; Legrand, Anais; Davis, Christopher; McGoldrick, Rory; Long, Chao; Pham, Hung
2016-01-01
Background: Xeroform remains the current standard for treating superficial partial-thickness burns but can be prohibitively expensive in developing countries with prevalent burn injuries. This study (1) describes the production of an alternative low-cost dressing and (2) compares the alternative dressing and Xeroform using the metrics of cost-effectiveness, antimicrobial activity, and biocompatibility in vitro, and wound healing in vivo. Methods: To produce the alternative dressing, 3% bismuth tribromophenate powder was combined with petroleum jelly by hand and applied to Kerlix gauze. To assess cost-effectiveness, the unit costs of Xeroform and components of the alternative dressing were compared. To assess antimicrobial properties, the dressings were placed on agar plated with Escherichia coli and the Kirby-Bauer assay performed. To assess biocompatibility, the dressings were incubated with human dermal fibroblasts and cells stained with methylene blue. To assess in vivo wound healing, dressings were applied to excisional wounds on rats and the rate of re-epithelialization calculated. Results: The alternative dressing costs 34% of the least expensive brand of Xeroform. Antimicrobial assays showed that both dressings had similar bacteriostatic effects. Biocompatibility assays showed that there was no statistical difference (P < 0.05) in the cytotoxicity of Xeroform, alternative dressing, and Kerlix gauze. Finally, the in vivo healing model showed no statistical difference (P < 0.05) in mean re-epithelialization time between Xeroform (13.0 ± 1.6 days) and alternative dressing (13.5 ± 1.0 days). Conclusions: Xeroform is biocompatible, reduces infection, and enhances healing of burn wounds by preventing desiccation and mechanical trauma. Handmade petrolatum gauze may be a low-cost replacement for Xeroform. Future studies will focus on clinical trials in burn units. PMID:27482485
Nherera, Leo; Trueman, Paul; Roberts, Christopher; Berg, Leena
2018-02-23
Burn injury is a common type of traumatic injury that causes considerable morbidity and mortality, resulting in about 30,000 admissions annually in specialist burn centers and costing around $1 billion per year in the United States. One percent silver sulfadiazine has been utilized widely in the management of burns and newer silver dressings are on the market, including nanocrystalline silver dressings, silver-impregnated hydrofiber dressings, and silver-impregnated foam dressings. This study sought to determine the cost effectiveness of the newer silver dressings using clinical data from an indirect treatment comparison using silver sulfadiazine as the baseline. A decision analytic model was developed from a US payer's perspective for burn patients with a total body surface area of < 20%. Outcomes were length of stay, infections and incidence of surgical procedures, quality adjusted life years (QALYs), and cost. The meta-analysis reported a statistically significant reduction in length of hospital stay and clinically important reductions in infections and incidence of surgical procedures in favor of the silver barrier dressing compared with other silver dressings. The estimated QALYs were 0.970 versus 0.969 versus 0.969 and mean cost per patient was $15,892, $23,799, and $24,269 for the nanocrystalline silver dressing, silver-impregnated hydrofiber dressing, and silver-impregnated foam dressing, respectively. The analysis showed the nanocrystalline silver dressing to be a dominant strategy (less costly with better outcomes). These findings were robust to a range of sensitivity analyses. According to data from an indirect treatment comparison, this analysis suggests that nanocrystalline silver dressing is the most cost-effective silver delivery system. Prospective head-to-head research on the costs and outcomes of these silver delivery systems in this patient population is necessary to validate the results of this economic evaluation.
Gee Kee, Emma; Kimble, Roy M; Cuttle, Leila; Stockton, Kellie
2013-11-25
In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤ 10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Australian New Zealand Clinical Trials Registry ACTRN12613000105741.
Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.
Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C
2013-07-01
Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.
Atypical cause of forearm skin ulceration in a leukaemic child: mucormycosis. A case report.
Zirak, C; Brutus, J P; De Mey, A
2005-01-01
Primary cutaneous mucormycosis is an uncommon, deep and aggressive fungal infection occurring mainly in immunosuppressed or diabetic patients. Rapid diagnosis and therapy are necessary to prevent a fatal outcome. An eight-year-old leukaemic child presented with a dark necrotic ulcer on the volar-ulnar aspect of the left forehand. The lesion had developed over seven days, beginning as a vasculo-haemorrhagic erythematous plaque. There was no known history of trauma to the area, but skin necrosis from external compression caused by an intravenous line could not be completely ruled out. The lesion rapidly progressed to a 5 x 8 cm painful necrotic ulcer with an erythematous border. Treatment with ichthyol dressing and intra-venous antibiotherapy failed to improve the condition. Wide debridement was performed and specimens were sent for microbiology and pathology examinations. Microscopic examination demonstrated broad, irregularly walled, non-septate fungal hyphae that were consistent with Mucor. Amphotericin B was administrated intravenously (1 mg/kg/day) and hydrogel and hydrophile adhesive polyurethane foam dressings were applied. After 12 days, the soft tissue defect was covered with a split-thickness skin graft, harvested from the lateral aspect of the thigh. Diagnosis of this infection is based on complete histopathological and microbiological studies. Awareness, and a high index of suspicion are required because of the potential fulminant and fatal course.
Correction of accessory axillary breast tissue without visible scar.
Kim, Young Soo
2004-01-01
Various methods for correction of accessory axillary breast tissue have been proposed, including simple excision, diamond-shaped excision, a Y-V technique, and lipoplasty. We present an effective method for correction of a prominent axillary mound that combines lipoplasty with excision of accessory breast tissue along the axillary transverse line. Preoperative markings included an incision within the natural wrinkle line in the axillary fold, and demarcation of areas in which lipoplasty and excision were to be performed. After lipoplasty, deep dissection was performed to isolate and remove accessory breast tissue and excess fat tissue. A compression dressing was applied for 1 to 2 weeks postoperatively, and the patient was instructed to wear a sports bra for 1 to 2 months after removal of the dressing. We treated 7 patients using this procedure between October 1999 and March 2003. No major postoperative complications were detected and recurrence was not noted during the follow-up periods. Aesthetic results were satisfactory. We believe that a procedure that combines lipoplasty and excision provides numerous advantages as a surgical option in treating a prominent axillary mound. The main advantage is that the final scar is laid in the natural axillary fold, rendering scars less conspicuous and eliminating the need to remove excess skin. The one disadvantage was that elevation of the skin flap via small, remote incisions initially produced surgical difficulties, but these were overcome with experience.
Klode, J; Schöttler, L; Stoffels, I; Körber, A; Schadendorf, D; Dissemond, J
2011-08-01
In the process of chronic wound care, adhesive wound dressings may cause pain and injury in the wound environment during dressing changes. At present, no standardized test procedures are available for the investigation of adhesion of wound dressings. Therefore, our study aimed to test the adhesion of different wound dressings on steel as well as on healthy skin. Within an open, comparative study, the adhesive areas of 56 wound dressings were investigated. The adhesives were categorized into acrylate (n = 23), silicone (n = 9), hydrocolloid (n = 17) and polyurethane groups (n = 7). Using an especially modified testing machine, the adhesion of the wound dressings was measured on steel as well as on the skin of healthy study participants, in compliance with the European EN 1939:2003 standard. The energy required to remove the wound dressings from human skin, was measured in Newton (N) and the following median values were obtained: hydrocolloid (2.25 N) > acrylate (1.14 N) > polyurethane (0.9 N) > silicone (0.7 N). The subjective pain intensity during the removal of the wound dressings was recorded using the visual analogue scale (VAS) with values ranging from 0 to 10. For hydrocolloid, it was 6.8, for acrylate 4.9, for polyurethane 3.1 and for silicone 2.5 points VAS. In comparison with human skin, the adhesion of wound dressings was significantly higher on steel (P < 0.0001), but was different for the different groups of wound dressings. Moreover, there was a statistically significant correlation between the adhesion and pain intensity (correlation coefficient 0.806; P = 0.01). The knowledge about the widely differing adhesion properties of different wound dressings on the skin of patients should nowadays be considered during the individual selection of the applied products. Based on these data, different types of wound dressings could be developed, guaranteeing a good adhesion and a low traumatic risk when removed. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.
NASA Astrophysics Data System (ADS)
Shan, S. Ali; Saleem, H.
2018-05-01
Electrostatic solitary waves and double layers (DLs) formed by the coupled ion acoustic (IA) and drift waves have been investigated in non-uniform plasma using q-nonextensive distribution function for the electrons and assuming ions to be cold Ti< Te. It is found that both compressive and rarefactive nonlinear structures (solitary waves and DLs) are possible in such a system. The steeper gradients are supportive for compressive solitary (and double layers) and destructive for rarefactive ones. The q-nonextensivity parameter q and the magnitudes of gradient scale lengths of density and temperature have significant effects on the amplitude of the double layers (and double layers) as well as on the speed of these structures. This theoretical model is general which has been applied here to the F-region ionosphere for illustration.
Dependence of energy characteristics of ascending swirling air flow on velocity of vertical blowing
NASA Astrophysics Data System (ADS)
Volkov, R. E.; Obukhov, A. G.; Kutrunov, V. N.
2018-05-01
In the model of a compressible continuous medium, for the complete Navier-Stokes system of equations, an initial boundary problem is proposed that corresponds to the conducted and planned experiments and describes complex three-dimensional flows of a viscous compressible heat-conducting gas in ascending swirling flows that are initiated by a vertical cold blowing. Using parallelization methods, three-dimensional nonstationary flows of a polytropic viscous compressible heat-conducting gas are constructed numerically in different scaled ascending swirling flows under the condition when gravity and Coriolis forces act. With the help of explicit difference schemes and the proposed initial boundary conditions, approximate solutions of the complete system of Navier-Stokes equations are constructed as well as the velocity and energy characteristics of three-dimensional nonstationary gas flows in ascending swirling flows are determined.
Ginzburg, N S; Zotova, I V; Sergeev, A S
2010-12-31
Based on analogy to the well-known process of the self-induced transparency of an optical pulse propagating through a passive two-level medium we describe similar effects for a microwave pulse interacting with a cold plasma or rectilinear electron beam under cyclotron resonance condition. It is shown that with increasing amplitude and duration of an incident pulse the linear cyclotron absorption is replaced by the self-induced transparency when the pulse propagates without damping. In fact, the initial pulse decomposes to one or several solitons with amplitude and duration defined by its velocity. In a certain parameter range, the single soliton formation is accompanied by significant compression of the initial electromagnetic pulse. We suggest using the effect of self-compression for producing multigigawatt picosecond microwave pulses.
Renda, Francesca; Landoni, Giovanni; Bertini Malgarini, Renato; Assisi, Alessandro; Azzolini, Maria Luisa; Mucchetti, Marta; Pimpinella, Giuseppe; Pani, Luca
2015-12-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a rare, severe and potentially fatal cutaneous adverse drug reaction (the mortality rate is up to 10 %) associated with numerous and apparently heterogeneous drugs. The aetiology is unknown. To report Italian cases of DRESS over a 10-year period. We searched the National Pharmacovigilance Network (NPN) for the term 'drug reaction with eosinophilia and systemic symptoms' from 1 January 2004 to 1 January 2014, to identify all reports of DRESS. Each case was checked to avoid duplication. In the NPN, we identified 91 serious cases of DRESS: 68 were spontaneous, still-unpublished reports, while 23 additional cases were derived from screening of the scientific literature, performed by marketing authorization holders. Notably, the single common element linking all cases of DRESS was intake of a drug containing an aromatic ring. Thanks to the largest national DRESS case series ever reported, we were able to hypothesize, for the first time, that there is an association between use of drugs containing an aromatic ring in their chemical structure and DRESS. This might aid understanding of the aetiology of DRESS and facilitate diagnosis.
NASA Astrophysics Data System (ADS)
Wei, Qilin; Xu, Feiyang; Xu, Xingjian; Geng, Xue; Ye, Lin; Zhang, Aiying; Feng, Zengguo
2016-06-01
The non-woven wound dressing with core-shell structured fibers was prepared by coaxial electrospinning. The polycaprolactone (PCL) was electrospun as the fiber's core to provide mechanical strength whereas collagen was fabricated into the shell in order to utilize its good biocompatibility. Simultaneously, the silver nanoparticles (Ag-NPs) as anti-bacterial agent were loaded in the shell whereas the vitamin A palmitate (VA) as healing-promoting drug was encapsulated in the core. Resulting from the fiber's core-shell structure, the VA released from the core and Ag-NPs present in the shell can endow the dressing both heal-promoting and anti-bacteria ability simultaneously, which can greatly enhance the dressing's clinical therapeutic effect. The dressing can maintain high swelling ratio of 190% for 3 d indicating its potential application as wet dressing. Furthermore, the dressing's anti-bacteria ability against Staphylococcus aureus was proved by in vitro anti-bacteria test. The in vitro drug release test showed the sustainable release of VA within 72 h, while the cell attachment showed L929 cells can well attach on the dressing indicating its good biocompatibility. In conclusion, the fabricated nanofibrous dressing possesses multiple functions to benefit wound healing and shows promising potential for clinical application.
Imran, Muhammad; Hussain, Muhammad Barkaat; Baig, Mukhtiar
2015-10-01
To investigate the effect of Beri-honey-impregnated dressing on diabetic foot ulcer and compare it with normal saline dressing. A randomized, controlled trial. Sughra Shafi Medical Complex, Narowal, Pakistan and Bhatti International Trust (BIT) Hospital, Affiliated with Central Park Medical College, Lahore, from February 2006 to February 2010. Patients with Wagner's grade 1 and 2 ulcers were enrolled. Those patients were divided in two groups; group A (n=179) treated with honey dressing and group B (n=169) treated with normal saline dressing. Outcome measures were calculated in terms of proportion of wounds completely healed (primary outcome), wound healing time, and deterioration of wounds. Patients were followed-up for a maximum of 120 days. One hundred and thirty six wounds (75.97%) out of 179 were completely healed with honey dressing and 97 (57.39%) out of 169 wtih saline dressing (p=0.001). The median wound healing time was 18.00 (6 - 120) days (Median with IQR) in group A and 29.00 (7 - 120) days (Median with IQR) in group B (p < 0.001). The present results showed that honey is an effective dressing agent instead of conventional dressings, in treating patients of diabetic foot ulcer.
Nonpainful wide-area compression inhibits experimental pain
Honigman, Liat; Bar-Bachar, Ofrit; Yarnitsky, David; Sprecher, Elliot; Granovsky, Yelena
2016-01-01
Abstract Compression therapy, a well-recognized treatment for lymphoedema and venous disorders, pressurizes limbs and generates massive non-noxious afferent sensory barrages. The aim of this study was to study whether such afferent activity has an analgesic effect when applied on the lower limbs, hypothesizing that larger compression areas will induce stronger analgesic effects, and whether this effect correlates with conditioned pain modulation (CPM). Thirty young healthy subjects received painful heat and pressure stimuli (47°C for 30 seconds, forearm; 300 kPa for 15 seconds, wrist) before and during 3 compression protocols of either SMALL (up to ankles), MEDIUM (up to knees), or LARGE (up to hips) compression areas. Conditioned pain modulation (heat pain conditioned by noxious cold water) was tested before and after each compression protocol. The LARGE protocol induced more analgesia for heat than the SMALL protocol (P < 0.001). The analgesic effect interacted with gender (P = 0.015). The LARGE protocol was more efficient for females, whereas the MEDIUM protocol was more efficient for males. Pressure pain was reduced by all protocols (P < 0.001) with no differences between protocols and no gender effect. Conditioned pain modulation was more efficient than the compression-induced analgesia. For the LARGE protocol, precompression CPM efficiency positively correlated with compression-induced analgesia. Large body area compression exerts an area-dependent analgesic effect on experimental pain stimuli. The observed correlation with pain inhibition in response to robust non-noxious sensory stimulation may suggest that compression therapy shares similar mechanisms with inhibitory pain modulation assessed through CPM. PMID:27152691
21 CFR 169.150 - Salad dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...
21 CFR 169.115 - French dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false French dressing. 169.115 Section 169.115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
21 CFR 169.150 - Salad dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
Bogdanov, Volodymyr B.; Viganò, Alessandro; Noirhomme, Quentin; Bogdanova, Olena V.; Guy, Nathalie; Laureys, Steven; Renshaw, Perry F.; Dallel, Radhouane; Phillips, Christophe; Schoenen, Jean
2017-01-01
The mechanisms underlying conditioned pain modulation (CPM) are multifaceted. We searched for a link between individual differences in prefrontal cortex activity during multi-trial heterotopic noxious cold conditioning and modulation of the cerebral response to phasic heat pain. In 24 healthy female subjects, we conditioned laser heat stimuli to the left hand by applying alternatively ice-cold or lukewarm compresses to the right foot. We compared pain ratings with cerebral fMRI BOLD responses. We also analyzed the relation between CPM and BOLD changes produced by the heterotopic cold conditioning itself, as well as the impact of anxiety and habituation of cold-pain ratings. Specific cerebral activation was identified in precuneus and left posterior insula/SII, respectively, during early and sustained phases of cold application. During cold conditioning, laser pain decreased (n = 7), increased (n = 10) or stayed unchanged (n = 7). At the individual level, the psychophysical effect was directly proportional to the cold-induced modulation of the laser-induced BOLD response in left posterior insula/SII. The latter correlated with the BOLD response recorded 80 s earlier during the initial 10-s phase of cold application in anterior cingulate, orbitofrontal and lateral prefrontal cortices. High anxiety and habituation of cold pain were associated with greater laser heat-induced pain during heterotopic cold stimulation. The habituation was also linked to the early cold-induced orbitofrontal responses. We conclude that individual differences in conditioned pain modulation are related to different levels of prefrontal cortical activation by the early part of the conditioning stimulus, possibly due to different levels in trait anxiety. PMID:25461267
NASA Shines a Spotlight on a Webb Telescope Test
2013-12-11
Dressed in a clean room suit, NASA photographer Desiree Stover shines a light on the Space Environment Simulator's Integration Frame inside the thermal vacuum chamber at NASA's Goddard Space Flight Center in Greenbelt, Md. Shortly after, the chamber was closed up and engineers used this frame to enclose and help cryogenic (cold) test the heart of the James Webb Space Telescope, the Integrated Science Instrument Module. Credit: NASA/Goddard/Chris Gunn NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Control of Goos-Hänchen shift via input probe field intensity
NASA Astrophysics Data System (ADS)
Ziauddin; Lee, Ray-Kuang; Qamar, Sajid
2016-11-01
We suggest a scheme to control Goos-Hänchen (GH) shift in an ensemble of strongly interacting Rydberg atoms, which act as super-atoms due to the dipole blockade mechanism. The ensemble of three-level cold Rydberg-dressed (87Rb) atoms follows a cascade configurations where two fields, i.e, a strong control and a weak field are employed [D. Petrosyan, J. Otterbach, and M. Fleischhauer, Phys. Rev. Lett. 107, 213601 (2011)]. The propagation of probe field is influenced by two-photon correlation within the blockade distance, which are damped due to the saturation of super-atoms. The amplitude of GH shift in the reflected light depends on the intensity of probe field. We observe large negative GH shift in the reflected light for small values of the probe field intensities.
Electromagnetically induced grating with Rydberg atoms
NASA Astrophysics Data System (ADS)
Asghar, Sobia; Ziauddin, Qamar, Shahid; Qamar, Sajid
2016-09-01
We present a scheme to realize electromagnetically induced grating in an ensemble of strongly interacting Rydberg atoms, which act as superatoms due to the dipole blockade mechanism. The ensemble of three-level cold Rydberg-dressed (87Rb) atoms follows a cascade configuration where a strong standing-wave control field and a weak probe pulse are employed. The diffraction intensity is influenced by the strength of the probe intensity, the control field strength, and the van der Waals (vdW) interaction. It is noticed that relatively large first-order diffraction can be obtained for low-input intensity with a small vdW shift and a strong control field. The scheme can be considered as an amicable solution to realize the atomic grating at the microscopic level, which can provide background- and dark-current-free diffraction.
1981-05-01
2.13 14.20 - Mixer S.D. 1.05 4.92 - Oven Proofer Range Glazes (bread) X 1.28 3.69 - Range S.D. 1.12 2.91 - Mixer Dough (breed) X 4.53 9.34 - Mixer SS.D...Steamer S.D. 0 - - Tomatoes X 16.00 17.00 - Range S.D. 21.21 12.73 - Steam kettle Fryer Desserts: Cookies X 1.92 10.97 - Range S.D. 1.21 1.85 - Mixer...88.30 Salad Dressing 550 24.07 51.21 Sandwiches 1,100 346.69 307.14 Beverages, cold 550 93.33 88.92 Dessert, cookies 550 15.05 67.19 Totals 550 599.94 lb
ERIC Educational Resources Information Center
Dulin, Charles Dewitt
2016-01-01
The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…
Verbelen, Jozef; Hoeksema, Henk; Heyneman, Alexander; Pirayesh, Ali; Monstrey, Stan
2014-05-01
Studies comparing contemporary silver dressings in burns are scarce. In a prospective, randomized, controlled study, counting 50 patients/research group, we compared two frequently used silver dressings, Acticoat™ and Aquacel(®) Ag, in the management of partial thickness burns with a predicted healing time between 7 and 21 days as assessed by laser Doppler imaging between 48 and 72h after burn. Variables investigated were related to baseline research group characteristics, wound healing, bacteriology, economics, nurse, and patient experience. Both research groups were comparably composed taking into account gender, age and burn characteristics. Similar results were obtained as to healing time and bacterial control with both silver dressings. A statistically significant difference in favor of the Aquacel(®) Ag dressing was found for average ease of use (p<0.001), average ease of application (p=0.001), patient pain (p<0.001), patient comfort with the dressing (p=0.017), silver staining (p<0.001), and cost effectiveness (p<0.001). Both silver dressings resulted in comparable healing times and bacterial control but the Aquacel(®) Ag dressing significantly increased comfort for patients as well as nurses and was significantly more cost-effective than the Acticoat™ dressing for the given indication. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Davis, Stephen C; Li, Jie; Gil, Joel; Valdes, Jose; Solis, Michael; Higa, Alex; Bowler, Philip
2018-06-11
Topical antimicrobials are widely used to control wound bioburden and facilitate wound healing; however, the fine balance between antimicrobial efficacy and non-toxicity must be achieved. This study evaluated whether an anti-biofilm silver-containing wound dressing interfered with the normal healing process in non-contaminated deep partial thickness wounds. In an in-vivo porcine wound model using 2 pigs, 96 wounds were randomly assigned to 1 of 3 dressing groups: anti-biofilm silver Hydrofiber dressing (test), silver Hydrofiber dressing (control), or polyurethane film dressing (control). Wounds were investigated for 8 days, and wound biopsies (n = 4) were taken from each dressing group, per animal, on days 2, 4, 6, and 8 after wounding and evaluated using light microscopy. No statistically significant differences were observed in the rate of reepithelialisation, white blood cell infiltration, angiogenesis, or granulation tissue formation following application of the anti-biofilm silver Hydrofiber dressing versus the 2 control dressings. Overall, epithelial thickness was similar between groups. Some differences in infiltration of specific cell types were observed between groups. There were no signs of tissue necrosis, fibrosis, or fatty infiltration in any group. An anti-biofilm silver Hydrofiber wound dressing did not cause any notable interference with normal healing processes. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Payne, Wyatt G; Posnett, John; Alvarez, Oscar; Brown-Etris, Marie; Jameson, Gayle; Wolcott, Randall; Dharma, Hussein; Hartwell, Samantha; Ochs, Diane
2009-02-01
Modern dressings such as hydrocolloids, gels, and foams are typically more expensive than traditional dressings such as gauze. However, if modern dressings require fewer changes, the overall cost of treatment may be lower despite the higher initial purchase price. If healing rates are comparable or better, modern dressings also may be cost-effective. A 4-week, prospective, randomized clinical trial to assess differences in treatment costs and cost-effectiveness between a modern foam dressing and saline-soaked gauze was conducted among 36 patients (22 men, 14 women, mean age 72.8 years) with a Stage II pressure ulcer (mean duration 35 weeks) at five centers in the United States. Participants were randomized to treatment with a self-adhesive polyurethane foam (n = 20) or saline-soaked gauze dressing (n = 16). No difference in time to wound closure was observed (P = 0.817). Patients in the foam group had less frequent dressing changes (P <0.001). Total cost over the study period was lower by $466 per patient (P = 0.055) and spending on dressings was lower by $92 per patient in the foam group (P = 0.025). Cost per ulcer healed was lower by $1,517 and cost per ulcer-free day was lower by $80 for patients in the foam group. On the evidence of this study, the foam dressing is a more cost-effective treatment than saline-soaked gauze for the treatment of Stage II pressure ulcers.
Sustained compression and healing of chronic venous ulcers.
Blair, S. D.; Wright, D. D.; Backhouse, C. M.; Riddle, E.; McCollum, C. N.
1988-01-01
STUDY OBJECTIVE--Comparison of four layer bandage system with traditional adhesive plaster bandaging in terms of (a) compression achieved and (b) healing of venous ulcers. DESIGN--Part of larger randomised trial of five different dressings. SETTING--Outpatient venous ulcer clinic in university hospital. PATIENTS--(a) Pressure exerted by both bandage systems was measured in the same 20 patients. (b) Healing with the four layer bandage was assessed in 148 legs in 126 consecutive patients (mean age 71 (SE 2); range 30-96) with chronic venous ulcers that had resisted treatment with traditional bandaging for a mean of 27.2 (SE 8) months. INTERVENTIONS--(a) Four layer bandage system or traditional adhesive plaster bandaging for pressure studies; (b) four layer bandaging applied weekly for studies of healing. END POINTS--(a) Comparison of pressures achieved at the ankle for up to one week; (b) complete healing within 12 weeks. MEASUREMENTS AND MAIN RESULTS--(a) Four layer bandage produced higher initial pressures at the ankle of 42.5 (SE 1) mm Hg compared with 29.8 (1.8) for the adhesive plaster (p less than 0.001; 95% confidence interval 18.5 to 6.9). Pressure was maintained for one week with the four layer bandage but fell to 10.4 (3.5) mm Hg at 24 hours with adhesive plaster bandaging. (b) After weekly bandaging with the four layer bandage 110 of 48 venous ulcers had healed completely within 12 (mean 6.3 (0.4)) weeks. CONCLUSION--Sustained compression of over 40 mm Hg achieved with a multilayer bandage results in rapid healing of chronic venous ulcers that have failed to heal in many months of compression at lower pressures with more conventional bandages. PMID:3144330
Intravenous hemostats: challenges in translation to patients
NASA Astrophysics Data System (ADS)
Lashof-Sullivan, Margaret; Shoffstall, Andrew; Lavik, Erin
2013-10-01
Excessive bleeding and the resulting complications are a leading killer of young people globally. There are many successful methods to halt bleeding in the extremities, including compression, tourniquets, and dressings. However, current treatments for internal hemorrhage (including from head or truncal injuries), termed non-compressible bleeding, are inadequate. For these non-compressible injuries, blood transfusions are the current treatment standard. However, they must be refrigerated, may potentially transfer disease, and are of limited supply. In addition, time is of the essence for halting hemorrhage, since more than a third of civilian deaths due to hemorrhage from trauma occur before the patient even reaches the hospital. As a result, particles that can cross-link activated platelets through the glycoprotein IIb/IIIa receptor expressed on activated platelets are being investigated as an alternative treatment for non-compressible bleeding. Ideally, these particles would interact specifically with platelets to stabilize the platelet plug. Initial designs used biologically derived microparticles with red blood cell fragment or albumin cores decorated with RGD or fibrinogen, which bind to GPIIb/IIIa. More recently there has been research into the use of fully synthetic nanoparticles with liposomal or polymer cores that crosslink platelets through a targeting peptide bound to the surface. Some of the challenges for the development of these particles include appropriate sizing to prevent blocking the capillaries of the lungs, immune system evasion to prevent strong reactions and increase circulation time, and storage and resuspension so that first responders can easily use the particles. In addition, the effectiveness of the variety of animal bleeding models in predicting outcomes must be examined before test results can be fully understood. Progress has been made in the development of particles to combat hemorrhage, but issues of immune sensitivity and storage must be resolved before these types of particles can be translated for human use.
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...
Rationale for Student Dress Codes: A Review of School Handbooks
ERIC Educational Resources Information Center
Freeburg, Elizabeth W.; Workman, Jane E.; Lentz-Hees, Elizabeth S.
2004-01-01
Through dress codes, schools establish rules governing student appearance. This study examined stated rationales for dress and appearance codes in secondary school handbooks; 182 handbooks were received. Of 150 handbooks containing a rationale, 117 related dress and appearance regulations to students' right to a non-disruptive educational…
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
Commissioning of helium refrigeration system at JLab for 12 GeV upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganni, Venkatarao; Dixon, Kelly D.; Knudsen, Peter N.
The new 4.5 K refrigerator system added to the Jefferson Lab (JLab) Central Helium Liquefier (CHL) for the 12 GeV upgrade will double its previous capacity. It includes a 4.5 K cold box system and compressor system with associated oil removal and gas management systems. At its maximum capacity condition, this new system supports an additional 238 g/s 30 K 1.16 bar cold compressor return flow, a 15 g/s 4.5 K liquefaction load and a 12.6 kW 35–55 K shield load. Five more design conditions, ranging from liquefaction to refrigeration and a stand-by/reduced load state, were specified for the sizingmore » and selection of its components. The cold box system is comprised of a 300–60 K vertical cold box that incorporates a liquid nitrogen pre-cooler and a 60–4.5 K horizontal cold box housing seven turbines that are configured in four expansion stages including one Joule-Thompson expander. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will briefly review the salient 4.5 K system design features and discuss the recent commissioning results.« less
Colloidal silver-based nanogel as nonocclusive dressing for multiple superficial pellet wounds.
Dharmshaktu, Ganesh Singh; Singhal, Aanshu; Pangtey, Tanuja
2016-01-01
A good dressing is mandatory to an uncomplicated wound healing, especially when foreign particles contaminate the wound. Various forms of dressing preparations are available for use and differ in chemical composition and efficacy. Silver has been a known agent with good antimicrobial and healing properties and recent times has seen an upsurge in various silver-based dressing supplements. We describe our report of use and efficacy of a silver nanoparticle- based gel dressing in the healing of multiple superficial firearm pellet wounds.
Honey as a topical treatment for wounds.
Jull, Andrew B; Walker, Natalie; Deshpande, Sohan
2013-02-28
Honey is a viscous, supersaturated sugar solution derived from nectar gathered and modified by the honeybee, Apis mellifera. Honey has been used since ancient times as a remedy in wound care. Evidence from animal studies and some trials has suggested that honey may accelerate wound healing. The objective was to determine whether honey increases the rate of healing in acute wounds (e.g. burns, lacerations) and chronic wounds (e.g. skin ulcers, infected surgical wounds). For this first update of the review we searched the Cochrane Wounds Group Specialised Register (searched 13 June 2012); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 5); Ovid MEDLINE (2008 to May Week 5 2012); Ovid MEDLINE (In-Process & Other Non-Indexed Citations 12 June 2012); Ovid EMBASE (2008 to 2012 Week 23); and EBSCO CINAHL (2008 to 8 June 2012). Randomised and quasi-randomised trials that evaluated honey as a treatment for any sort of acute or chronic wound were sought. There was no restriction in terms of source, date of publication or language. Wound healing was the primary endpoint. Data from eligible trials were extracted and summarised by one review author, using a data extraction sheet, and independently verified by a second review author. We identified 25 trials (with a total of 2987 participants) that met the inclusion criteria, including six new trials that were added to this update. In acute wounds, three trials evaluated the effect of honey in acute lacerations, abrasions or minor surgical wounds and 12 trials evaluated the effect of honey in burns. In chronic wounds, two trials evaluated the effect of honey in venous leg ulcers, and single trials investigated its effect in infected post-operative wounds, pressure injuries, cutaneous Lieshmaniasis, diabetic foot ulcers and Fournier's gangrene. Three trials recruited people into mixed groups of chronic or acute wounds. Most trials were at high or unclear risk of bias. In acute wounds, specifically partial-thickness burns, honey might reduce time to healing compared with some conventional dressings (WMD -4.68 days, 95%CI -4.28 to -5.09 days), but, when compared with early excision and grafting, honey delays healing in partial- and full-thickness burns (WMD 13.6 days, 95% CI 10.02 to 17.18 days). In chronic wounds, honey does not significantly increase healing in venous leg ulcers when used as an adjuvant to compression (RR 1.15, 95% CI 0.96 to 1.38), and may delay healing in cutaneous Leishmaniasis when used as an adjuvant to meglumine antimoniate compared to meglumine antimoniate alone (RR 0.72, 95% CI 0.51 to 1.01). Honey dressings do not increase rates of healing significantly in venous leg ulcers when used as an adjuvant to compression. Honey may delay healing in partial- and full-thickness burns in comparison to early excision and grafting, and in cutaneous Leishmaniasis when used as an adjuvant with meglumine antimoniate. Honey might be superior to some conventional dressing materials, but there is considerable uncertainty about the replicability and applicability of this evidence. There is insufficient evidence to guide clinical practice in other types of wounds, and purchasers should refrain from providing honey dressings for routine use until sufficient evidence of effect is available.
Self adhesive dressing pouch for the protection of catheters.
de la Cruz Martínez, Maria Teresa; Hernández, María José
2002-01-01
This paper is about a new model of dressing, used for the protection of all types of temporary and permanent catheters. Those who developed this dressing realised the practical difficulties during the placement and removal of traditional dressings, used in haemodialysis units. They also realised that it this was unpleasant for the patients, and there was a risk to the catheters when removing the dressings because of the use of scissors and other cutting instruments. This new dressing solves these previously mentioned problems and at the same time contributes to the comfort of the patients. The model has been registered as a standard using model, and therefore it is protected by law and its copyright (Intellectual Property).
[Current wound care in patients with elephantiasis--third-stage lymphedema].
Rucigaj, Tanja Planinsek; Slana, Ana; Leskovec, Nada Kecelj
2012-10-01
Lymphedema resulting from fluid accumulation due to impairment in the lymphatic system drainage leads to enlargement of the body part involved. If left untreated, in its third stage it results in elephantiasis. Elephantiasis is frequently accompanied by papillomatosis and lymphocutaneous fistulas with lymphorrhoea, erosions and ulcers, frequently with the loss of function in the respective part of the body. Unlike other chronic wounds, wound healing in lymphedema is highly dependent on the use of combined therapies because local treatment with modern supportive dressings and compression therapy with adhesive and non-adhesive short-stretch systems is only part of the complete treatment. This treatment also includes sub-bandage foamy materials, kinesitherapy with tapes (kinesiotaping), intermittent local application of high-pressure oxygen, breathing exercise, and manual lymph drainage and exercises.
Tunable electromagnetically induced transparency and absorption with dressed superconducting qubits
NASA Astrophysics Data System (ADS)
Ian, Hou; Liu, Yu-Xi; Nori, Franco
2010-06-01
Electromagnetically induced transparency and absorption (EIT and EIA) are usually demonstrated using three-level atomic systems. In contrast to the usual case, we theoretically study the EIT and EIA in an equivalent three-level system: a superconducting two-level system (qubit) dressed by a single-mode cavity field. In this equivalent system, we find that both the EIT and the EIA can be tuned by controlling the level-spacing of the superconducting qubit and hence controlling the dressed system. This tunability is due to the dressed relaxation and dephasing rates which vary parametrically with the level-spacing of the original qubit and thus affect the transition properties of the dressed qubit and the susceptibility. These dressed relaxation and dephasing rates characterize the reaction of the dressed qubit to an incident probe field. Using recent experimental data on superconducting qubits (charge, phase, and flux qubits) to demonstrate our approach, we show the possibility of experimentally realizing this proposal.
Childress, Beverly B; Berceli, Scott A; Nelson, Peter R; Lee, W Anthony; Ozaki, C Keith
2007-09-01
Surgical wounds for lower extremity revascularization are prone to infection and dehiscence. Acticoat Absorbent, an antimicrobial dressing, offers sustained release of ionic silver. We hypothesized that immediate application of Acticoat as a postoperative dressing would reduce wound complications in patients undergoing leg revascularization. All infrainguinal revascularization cases involving leg incisions at a single Veterans Administration Medical Center were identified from July 1, 2002, to September 30, 2005. The control group received conventional dressings, while the treatment group received an Acticoat dressing. Wound complication rates were captured via National Surgical Quality Improvement Program data. Patient characteristics and procedure distributions were similar between groups. The wound complication rate fell 64% with utilization of the Acticoat-based dressing (control 14% [17/118], treatment 5% [7/130]; P = 0.016). An Acticoat-based dressing system offers a potentially useful, cost-effective adjunct to reduce open surgical leg revascularization wound complications.
NASA Astrophysics Data System (ADS)
Lorenz, Robby; Hagenah, Hinnerk; Merklein, Marion
2018-05-01
Cold forging processes such as forward rod extrusion can be used to produce high quality components like connection rods, shafts and gears. The main advantages of these extruded components are sufficient surface quality, work hardening, compressive residual stresses and fatigue strength. Since one technical disadvantage of extruded components lies in the achievable tolerance classes, the improvement of these should be of crucial importance. For instance, the attainable workpiece accuracy and component quality can be influenced by adapting the tribological system in such a way that the resulting friction is specifically controlled in order to improve component forming. Lubricant modification is one practical way of adapting the tribological system to the requirements of the forming process. An industrial established and highly efficient lubricant system is the application of a zinc-phosphate conversion layer with a molybdenum disulfide-based lubricant. While offering many advantages, its tribological conditions seem to depend strongly on the layer weight and the application strategy. These parameters and the respective interdependencies have not been sufficiently investigated yet. In order to examine this, the tribological conditions depending on the layer weight are analyzed in greater detail using the Ring-Compression-Test (RCT). This tribometer provides a comparative representation of the forming conditions during cold forging. Furthermore, a potential dependency between the tribological conditions and two different coating techniques is analyzed. The latter are represented by the industrial standards dipping and dip-drumming.
School Dress Codes v. The First Amendment: Ganging up on Student Attire.
ERIC Educational Resources Information Center
Jahn, Karon L.
Do school dress codes written with the specific purpose of limiting individual dress preferences, including dress associated with gangs, infringe on speech freedoms granted by the First Amendment of the U.S. Constitution? Although the Supreme Court has extended its protection of political speech to nonverbal acts of communication, it has…
Dressing of Cognitively Impaired Nursing Home Residents: Description and Analysis
ERIC Educational Resources Information Center
Cohen-Mansfield, Jiska; Creedon, Michael A.; Malone, Thomas; Parpura-Gill, Aleksandra; Dakheel-Ali, Maha; Heasly, Christopher
2006-01-01
Purpose: Getting dressed is an activity that is of particular difficulty for many persons with dementia, given the need for hand-eye coordination, fine motor skills, and overall planning skills. Despite several studies concerning interventions to improve dressing behavior, very little is known about the dressing process as it is currently…
Women in relationships with cross-dressing men: a descriptive study from a nonclinical setting.
Brown, G R
1994-10-01
Over a 6-year period, 106 women involved with men who cross-dress (mostly heterosexual transvestites) completed a questionnaire regarding themselves, their male partners, and their relationships. Interview data supplemented these questionnaires for 75% of the respondents. All respondents were recruited from nonclinical settings. The "modal" female partner was a 40-year-old Protestant, Caucasian woman, who was a firstborn child, in her first marriage. She was more likely than other women her age to be childless, and to have earned at least a 2-year college degree. She was no more likely to have had lesbian experiences or substance use problems than comparably aged American women. She had been married to her cross-dressing mate for 13 years and had known of his activities for 9 years. A quarter of women reported at least occasional sexual arousal to their mate's cross-dressing. The two variables associated with low acceptance of cross-dressing were discovery of their partner's cross-dressing after marriage and lack of sexual arousal to cross-dressing stimuli. Low acceptance was unrelated to firstborn status, amount of exposure to cross-dressing activities, or having had children. This group may be more representative of women in relationships with cross-dressing men than previous reports limited to cross-dressers and spouses who are in treatment.
Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.
Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G
2016-01-01
Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.
Salome, G M; de Brito, M J A; Ferreira, L M
2014-09-01
To assess self-esteem in patients with venous leg ulcers treated with Unna's boot. • A descriptive, analytic, clinical study was conducted from June 2010 to May 2011 in an outpatient wound care clinic in São Paulo, Brazil. Patients of both sexes, aged ≥18 years, who had had a venous leg ulcer for more than one year and a Doppler ankle brachial index ranging from 0.8-1.0 were consecutively selected for inclusion. Patients were treated with wound dressings and Unna's boot. Self-esteem was assessed using the Brazilian version of the Rosenberg Self-Esteem Scale (RSE) at inclusion (baseline) and after 4, 8, and 12 months of compression therapy using Unna's boot. The scale is reverse-scored; thus lower scores indicate higher levels of self-esteem. • The patients showed a slight but significant improvement in self-esteem after 4 months of treatment (mean RSE score=17.12) compared with baseline (mean RSE score=24.90). However, a marked and significant improvement in self-esteem was observed after 8 months (mean RSE score=7.40) and 12 months (mean RSE score=2.10) of compression therapy using Unna's boot. • Patients with venous leg ulcers treated with Unna's boot for 12 months showed a significant improvement in self-esteem • All authors declare that no competing financial interests exist. There was no external funding for this study.
Jovanović, Zeljka; Radosavljević, Aleksandra; Kačarević-Popović, Zorica; Stojkovska, Jasmina; Perić-Grujić, Aleksandra; Ristić, Mirjana; Matić, Ivana Z; Juranić, Zorica D; Obradovic, Bojana; Mišković-Stanković, Vesna
2013-05-01
Silver/poly(N-vinyl-2-pyrrolidone) (Ag/PVP) nanocomposites containing Ag nanoparticles at different concentrations were synthesized using γ-irradiation. Cytotoxicity of the obtained nanocomposites was determined by MTT assay in monolayer cultures of normal human immunocompetent peripheral blood mononuclear cells (PBMC) that were either non-stimulated or stimulated to proliferate by mitogen phytohemagglutinin (PHA), as well as in human cervix adenocarcinoma cell (HeLa) cultures. Silver release kinetics and mechanical properties of nanocomposites were investigated under bioreactor conditions in the simulated body fluid (SBF) at 37°C. The release of silver was monitored under static conditions, and in two types of bioreactors: perfusion bioreactors and a bioreactor with dynamic compression coupled with SBF perfusion simulating in vivo conditions in articular cartilage. Ag/PVP nanocomposites exhibited slight cytotoxic effects against PBMC at the estimated concentration of 0.4 μmol dm(-3), with negligible variations observed amongst different cell cultures investigated. Studies of the silver release kinetics indicated internal diffusion as the rate limiting step, determined by statistically comparable results obtained at all investigated conditions. However, silver release rate was slightly higher in the bioreactor with dynamic compression coupled with SBF perfusion as compared to the other two systems indicating the influence of dynamic compression. Modelling of silver release kinetics revealed potentials for optimization of Ag/PVP nanocomposites for particular applications as wound dressings or soft tissue implants. Copyright © 2013 Elsevier B.V. All rights reserved.
Human neutrophil elastase and collagenase sequestration with phosphorylated cotton wound dressings.
Edwards, J Vincent; Howley, Phyllis S
2007-11-01
The design and preparation of wound dressings that redress the protease imbalance in chronic wounds is an important goal of wound healing and medical materials science. Chronic wounds contain high levels of tissue and cytokine-destroying proteases including matrix metalloprotease and neutrophil elastase. Thus, the lowering of excessive protease levels in the wound environment by wound dressing sequestration prevents the breakdown of extracellular matrix proteins and growth factors necessary for wound healing. Phosphorylated cotton wound dressings were prepared to target sequestration of proteases from chronic wound exudate through a cationic uptake binding mechanism involving salt bridge formation of the positively charged amino acid side chains of proteases with the phosphate counterions of the wound dressing fiber. Dressings were prepared by applying sodium hexametaphosphate and diammonium phosphate in separate formulations to cotton gauze by pad/dry/cure methods. Phosphorylated cotton dressings were assessed for their ability to lower elastase and collagenase activity. The phosphorylated cotton dressings lowered elastase and collagenase activity 40-80% more effectively than the untreated cotton wound dressings under conditions that mimic chronic wound exudate. Efficacy of the phosphorylated cotton was found to be related to the level of phosphorylation and a lower pH due to protonated phosphate at the surface of the dressing. The capacity of the modified gauze to sequester continued elastase secretions similar to that found in a chronic wound over a 24-h period was retained within a 80% retention of elastase sequestration and was dose-dependent. Copyright (c) 2007 Wiley Periodicals, Inc.
Analysis of the Pressure Distribution Qualities of a Silicone Border Foam Dressing.
Miller, Stephannie K; Sharma, Neal; Aberegg, Lauren C; Blasiole, Kimberly N; Fulton, Judith A
2015-01-01
To determine whether application of a silicone foam dressing is associated with decreased interface pressures when applied to the heel. Prospective, within-subjects design. The study was conducted in a community-based hospital using a convenience sample of 50 healthy volunteers with a mean age of 39.6 years and mean body mass index of 26.6; 70% were female. Application of the silicone border foam dressing was randomized between the left and right heels. Participants were asked to lie down in the supine position on a viscoelastic foam mattress. Interface pressure measurements were captured using a pressure mapping system; measurements were taken once with the dressing applied to the heel (intervention map) and once without (control map). Data were captured after a 4-minute time period allowing stabilization. Analysis was based on mean interface pressure; data points were collected for both heels in each of the 2 frames, yielding 4 observations per subject. Application of the dressing was associated with a significant decrease in average pressure measurements as compared to the heel with no dressing applied (P < .001). Application of the dressing did not impact pressure readings for the heel to which no dressing was applied (P = .53), and application of the dressing to either the left or right heel did not impact pressure readings (ie, the random effect was insignificant; P = .9). Application of a silicone border foam dressing is associated with significant reduction in interface pressure and may be considered as part of a pressure ulcer prevention program.
Enhanced wound contraction in fresh wounds dressed with honey in Wistar rats (Rattus Novergicus).
Osuagwu, F C; Oladejo, O W; Imosemi, I O; Aiku, A; Ekpos, O E; Salami, A A; Oyedele, O O; Akang, E U
2004-01-01
Due to reports that honey accelerates wound healing, an investigation on its role in wound contraction in fresh wounds inflicted on wistar rats was carried out. Twenty adult male wistar rats had 2cm by 2cm square wound inflicted on their right dorsolateral trunk. They were divided into two groups. The experimental group had their wounds dressed with honey while the control group had normal saline dressing. Wound dressing was done every five days and measurements taken at each dressing. Wound morphology was also assessed. Dressing with honey significantly enhanced percentage wound contraction on day 10 with value of 79.20+/-2.94 compared to control value of 53.50+/-4.32. p=0.0. The mean wound measurement on day 10 reduced significantly in honey group, 1.15+/-0.18 compared to control group 2.38+/-0.28. p=0.002. However, there was no significant difference in fibroblast count per high power field in honey group 68.0+/-2.59 compared to control 90.2+/-17.40, p=0.242. Honey dressing increased mean blood vessel count per high power field, 18.8+/-3.77 albeit non significantly when compared to control value of 13.4+/-2.44, p=0.264. Also honey dressing caused increased granulation tissue formation in wounds dressed with honey compared to control group. Our study suggests that honey dressing enhances wound contraction in fresh wounds which is one of the key features of wound healing.
Processing parameter optimization for the laser dressing of bronze-bonded diamond wheels
NASA Astrophysics Data System (ADS)
Deng, H.; Chen, G. Y.; Zhou, C.; Li, S. C.; Zhang, M. J.
2014-01-01
In this paper, a pulsed fiber-laser dressing method for bronze-bonded diamond wheels was studied systematically and comprehensively. The mechanisms for the laser dressing of bronze-bonded diamond wheels were theoretically analyzed, and the key processing parameters that determine the results of laser dressing, including the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles, were proposed for the first time. Further, the effects of these four key parameters on the oxidation-damaged layer of the material surface, the material removal efficiency, the material surface roughness, and the average protrusion height of the diamond grains were explored and summarized through pulsed laser ablation experiments. Under the current experimental conditions, the ideal values of the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles were determined to be 4.2 × 107 W/cm2, 30%, 30%, and 16, respectively. Pulsed laser dressing experiments were conducted on bronze-bonded diamond wheels using the optimized processing parameters; next, both the normal and tangential grinding forces produced by the dressed grinding wheel were measured while grinding alumina ceramic materials. The results revealed that the normal and tangential grinding forces produced by the laser-dressed grinding wheel during grinding were smaller than those of grinding wheels dressed using the conventional mechanical method, indicating that the pulsed laser dressing technology provides irreplaceable advantages relative to the conventional mechanical dressing method.
Siritientong, Tippawan; Angspatt, Apichai; Ratanavaraporn, Juthamas; Aramwit, Pornanong
2014-01-01
An ethyl alcohol-precipitated silk sericin/PVA scaffold that controlled the release of silk sericin was previously developed and applied for the treatment of full-thickness wounds in rats and demonstrated efficient healing. In this study, we aimed to further evaluate the clinical potential of this scaffold, hereafter called "silk sericin-releasing wound dressing", for the treatment of split-thickness skin graft donor sites by comparison with the clinically available wound dressing known as "Bactigras®". In vitro characterization and in vivo evaluation for safety of the wound dressings were performed. A clinical trial of the wound dressings was conducted according to standard protocols. The sericin released from the wound dressing was not toxic to HaCat human keratinocytes. A peel test indicated that the silk sericin-releasing wound dressing was less adhesive than Bactigras®, potentially reducing trauma and the risk of repeated injury upon removal. There was no evidence of skin irritation upon treatment with either wound dressing. When tested in patients with split-thickness skin graft donor sites, the wounds treated with the silk sericin-releasing wound dressing exhibited complete healing at 12 ± 5.0 days, whereas those treated with Bactigras® were completely healed at 14 ± 5.2 days (p = 1.99 × 10(-4)). In addition, treatment with the silk sericin-releasing wound dressing significantly reduced pain compared with Bactigras® particularly during the first 4 postoperative days (p = 2.70 × 10(-5) on day 1). We introduce this novel silk sericin-releasing wound dressing as an alternative treatment for split-thickness skin graft donor sites.
A model for quantitative evaluation of skin damage at adhesive wound dressing removal.
Matsumura, Hajime; Ahmatjan, Niyaz; Ida, Yukiko; Imai, Ryutaro; Wanatabe, Katsueki
2013-06-01
The removal of adhesive wound dressings from the wound surface involves a risk of damaging the intact stratum corneum and regenerating epithelium. Pain associated with the removal of wound dressings is a major issue for patients and medical personnel. Recently, wound dressings coated with a silicone adhesive have been developed to reduce such skin damage and pain on removal and they have received good evaluation in various clinical settings. However, there is neither a standard method to quantify whether or not the integrity of the stratum corneum and regenerating epithelium is retained or if both structures are damaged by the removal of wound dressings, nor are there standardised values with which to assess skin damage. We applied six different types of adhesive wound dressing on plain copy paper printed with black ink by a laser printer, removed the dressings, examined the adhesive-coated surface of the wound dressings using a high-power videoscope, and examined the stripped areas. Wound dressings coated with a silicone adhesive showed significantly less detachment of the stratum corneum and regenerating epithelium, followed by those coated with polyurethane, hydrocolloid, and acrylic adhesives. The assessment method utilised in this study revealed distinct differences between wound dressing types, but less variation in the evaluation outcome of each type. This assessment method may be useful for the evaluation of adhesive wound dressings, particularly during product development. However, further studies will be needed to examine the effectiveness of this assessment method in the clinical setting because the adherent properties of polyurethane and hydrocolloid adhesives may be altered by the absorption of water from the skin. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.
Effect of different wound dressings on cell viability and proliferation.
Paddle-Ledinek, Joanne E; Nasa, Zeyad; Cleland, Heather J
2006-06-01
Many new dressings have been developed since the early 1980s. Wound healing comprises cleansing, granulation/vascularization, and epithelialization phases. An optimum microenvironment and the absence of cytotoxic factors are essential for epithelialization. This study examines the effect of extracts of different wound dressings on keratinocyte survival and proliferation. Keratinocyte cultures were exposed for 40 hours to at least three extracts of each of the following wound dressings, which were tested in octuplicate: Acticoat, Aquacel-Ag, Aquacel, Algisite M, Avance, Comfeel Plus transparent, Contreet-H, Hydrasorb, and SeaSorb. Silicone extract provided the reference material. Controls were included of cells cultured in medium that had been incubated under conditions identical to those used with the extracts. Cell survival (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide reduction) and proliferation (5-bromo-2':-deoxyuridine incorporation) were measured. Extracts of silver-containing dressings (Acticoat, Aquacel-Ag, Contreet-H, and Avance) were most cytotoxic. Extracts of Hydrasorb were less cytotoxic but markedly affected keratinocyte proliferation and morphology. Extracts of alginate-containing dressings (Algisite M, SeaSorb, and Contreet-H) demonstrated high calcium concentrations, markedly reduced keratinocyte proliferation, and affected keratinocyte morphology. Extracts of Aquacel and Comfeel Plus transparent induced small but significant inhibition of keratinocyte proliferation. The principle of minimizing harm should be applied to the choice of wound dressing. Silver-based dressings are cytotoxic and should not be used in the absence of infection. Alginate dressings with high calcium content affect keratinocyte proliferation probably by triggering terminal differentiation of keratinocytes. Such dressings should be used with caution in cases in which keratinocyte proliferation is essential. All dressings should be tested in vitro before clinical application.
Role of natural polysaccharides in radiation formation of PVA hydrogel wound dressing
NASA Astrophysics Data System (ADS)
Varshney, Lalit
2007-02-01
Radiation processed PVA-polysaccharides hydrogels have been observed to be suitable for producing transparent, flexible, mechanically strong, biocompatible, effective and economical hydrogel dressings. The dressings were formed in single stage irradiation process achieving gel formation and sterilization at 25-30 kGy gamma radiation dose. No synthetic plasticizers and additives were used. Different formulations containing poly-vinylalcohol (PVA) and polysaccharides selected from combinations of agar and carrageenan were used to make the dressings. The selected polysaccharides themselves form thermo-reversible gels and degrade on irradiation. Using concentration of polysaccharides as low as 0.5-2% resulted in increase of tensile strength from 45 g/cm 2 to 411 g/cm 2, elongation from 30% to 410% and water uptake from 25% to 157% with respect to PVA gel without polysaccharides. Besides improving mechanical strength, agar contributes more to elongation and carrageenan to mechanical strength of the gel dressing. PVA formulations containing the polysaccharides show significantly different pre-gel viscosities behaviour. Increasing the concentration of agar in the formulation to about 2% converts the sheet gel to paste gel useful for filling wound cavities. The results indicate that pre irradiation network structure of the formulation plays an important role in determining mechanical properties of the irradiated gel dressing. Formulations containing 7-9% PVA, 0.5-1.5% carrageenan and 0.5-1% agar gave highly effective usable hydrogel dressings. Scanning electron micrographs show highly porous structure of the gel. Clinical trials of wound dressing on human patients established safety and efficacy of the dressing. The dressing has been observed to be useful in treating burns, non-healing ulcers of diabetes, leprosy and other external wounds. The dressings are now being marketed in India under different brand names.
Kleidon, Tricia M; Ullman, Amanda J; Gibson, Victoria; Chaseling, Brett; Schoutrop, Jason; Mihala, Gabor; Rickard, Claire M
2017-11-01
To evaluate feasibility of an efficacy trial comparing peripherally inserted central catheter (PICC) dressing and securement techniques to prevent complications and failure. This pilot, 3-armed, randomized controlled trial was undertaken at Royal Children's Hospital and Lady Cilento Children's Hospital, Brisbane, Australia, between April 2014 and September 2015. Pediatric participants (N = 101; age range, 0-18 y) were assigned to standard care (bordered polyurethane [BPU] dressing, sutureless securement device), tissue adhesive (TA) (plus BPU dressing), or integrated securement dressings (ISDs). Average PICC dwell time was 8.1 days (range, 0.2-27.7 d). Primary outcome was trial feasibility including PICC failure. Secondary outcomes were PICC complications, dressing performance, and parent and staff satisfaction. Protocol feasibility was established. PICC failure was 6% (2/32) with standard care, 6% (2/31) with ISD, and 3% (1/32) with TA. PICC complications were 16% across all groups. TA provided immediate postoperative hemostasis, prolonging the first dressing change until 5.5 days compared with 3.5 days and 2.5 days with standard care and ISD respectively. Bleeding was the most common reason for first dressing change: standard care (n = 18; 75%), ISD (n = 11; 69%), TA (n = 4; 27%). Parental satisfaction (median 9.7/10; P = .006) and staff feedback (9.2/10; P = .002) were most positive for ISD. This research suggests safety and acceptability of different securement dressings compared with standard care; securement dressings may also reduce dressing changes after insertion. Further research is required to confirm clinically cost-effective methods to prevent PICC failure. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Methods/Design Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. Discussion The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12613000105741 PMID:24274190
Choi, Young Suk; Gwak, Heui-Chul; Park, Jae Keun; Lim, Ji Yun; Yeo, Eui Dong; Park, Eunseok; Kim, Junyong; Lee, Young Koo
2018-04-13
Silver nanoparticle (AgNP)-containing dressings are used worldwide for the treatment of wounds; however, many studies have indicated that AgNPs are toxic to humans and cause cell death, primarily via apoptosis. In this study, the investigators compare the apoptotic effects of various AgNP dressing materials, with the hypothesis that nanosilver would be less toxic than ionic silver. For the in vivo experiments, Sprague-Dawley (SD) and streptozotocin (STZ)-induced diabetic rats were treated with 5 dressing materials: Aquacel Ag (product A, silver ion; ConvaTec, Berkshire, UK), Acticoat (product B, AgNP; Smith & Nephew, Fort Worth, TX), Medifoam Silver (product C, silver ion; Genewel Science Co Ltd, Seongnam, South Korea), PolyMem Silver (product D, AgNP; Ferris Mfg Corp, Fort Worth, TX), and Vaseline-impregnated dressing gauze (control; Unilever, London, UK). All treatments were applied 3 times per week. After 14 days of treatment, the SD and STZ rats were euthanized, and wound samples were examined for apoptosis. The analysis included immunohistochemistry, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, Western blotting, and reverse transcription polymerase chain reaction for a semiquantitative evaluation of apoptosis. The AgNP-containing dressing materials were more cytotoxic than the silver dressings. Compared with the AgNP dressing materials, no significant levels of apoptotic factors were observed in the silver dressing-treated wounds. The TUNEL staining showed that product C-dressed wounds contained the most apoptotic cells, while some apoptotic cells were observed in product B-dressed wounds. Moreover, apoptotic gene expression was altered, including a decline in B-cell lymphoma-2 and activation of caspase-3. This was most evident in wounds treated with product C. Interestingly, apoptotic gene expression was not induced in product A-treated wounds. Finally, product D had a relatively lower silver concentration and was less toxic than products A-C. Dressing materials containing AgNP have an antimicrobial effect. However, the authors observed that some AgNP dressings induced DNA damage and apoptosis. Although AgNP dressings did not cause significant acute apoptotic effects, they should be examined for cytotoxic effects in chronic wounds and should be used with caution when treating chronic wounds and those with low bacteria counts.
Prediction on flexural strength of encased composite beam with cold-formed steel section
NASA Astrophysics Data System (ADS)
Khadavi, Tahir, M. M.
2017-11-01
A flexural strength of composite beam designed as boxed shaped section comprised of lipped C-channel of cold-formed steel (CFS) facing each other with reinforcement bars is proposed in this paper. The boxed shaped is kept restrained in position by a profiled metal decking installed on top of the beam to form a slab system. This profiled decking slab is cast by using self-compacting concrete where the concrete is in compression when load is applied to the beam. Reinforcement bars are used as shear connector between slab and CFS as beam. A numerical analysis method proposed by EC4 is used to predict the flexural strength of the proposed composite beam. It was assumed that elasto-plastic behaviour is developed in the cross -sectional of the proposed beam. The calculated predicted flexural strength of the proposed beam shows reasonable flexural strength for cold-formed composite beam.
USDA-ARS?s Scientific Manuscript database
Understanding how wound dressings may be designed to address critical unsolved issues in wound repair and treatment influences the development of dressings and new concepts of promoting healing. The vast majority of commercial dressing materials focus on the physical aspects of wounds, e.g., acting ...
School Dress Codes and Uniform Policies.
ERIC Educational Resources Information Center
Anderson, Wendell
2002-01-01
Opinions abound on what students should wear to class. Some see student dress as a safety issue; others see it as a student-rights issue. The issue of dress codes and uniform policies has been tackled in the classroom, the boardroom, and the courtroom. This Policy Report examines the whole fabric of the debate on dress codes and uniform policies…
NASA Astrophysics Data System (ADS)
Li, Xinghua; Zhang, Dan; Sun, Ming; Li, Kangkang; Wang, Zhiguo; Zhang, Yanpeng
2018-04-01
We study different dressing effects in parametrically amplified four-wave mixing (PA-FWM) processes. By seeding a weak probe laser into the Stokes or anti-Stokes channel of the FWM, the gain process is generated in the so-called bright twin beams which are the probe and conjugate beams. The dressing types dramatically affect the gain factors in both the probe and conjugate channels. The gain factor of the FWM signal decreases under the cascade-type dressing and the signal's shape splits into two dips under this dressing type. However, the intensity of the FWM signal changes from suppression to enhancement under the parallel-type dressing. We will apply this switching process to all-optical switching.
Overview of Silk Fibroin Use in Wound Dressings.
Farokhi, Mehdi; Mottaghitalab, Fatemeh; Fatahi, Yousef; Khademhosseini, Ali; Kaplan, David L
2018-05-12
Recently, biomimetic wound dressings were introduced as potential replacements for treating skin injuries. Although there are some clinically available skin replacements, the range of wound types and locations necessitates a broader range of options for the clinic. Natural polymeric-based dressings are of central interest in this area due to their outstanding biocompatibility, biodegradability, low toxicity, and non-allergenic nature. Among them, silk fibroin (SF) has exceptional characteristics as a wound dressing. SF-based dressings can also be used as carriers for delivering drugs, growth factors, and bioactive agents to the wound area, while providing appropriate support for complete healing. In this review, we describe recent advances in the development of SF-based wound dressings for skin regeneration. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Xiaoli; Li, Fangfei; Zhou, Qiang
Here we report that the equation of state (EOS) of Mo is obtained by an integrated technique of laser-heated DAC and synchrotron X-ray diffraction. The cold compression and thermal expansion of Mo have been measured up to 80 GPa at 300 K, and 92 GPa at 3470 K, respectively. The P-V-T data have been treated with both thermodynamic and Mie–Gruneisen-Debye methods for the thermal EOS inversion. The results are self-consistent and in agreement with the static multi-anvil compression data of Litasov et al. (J. Appl. Phys. 113, 093507 (2013)) and the theoretical data of Zeng et al. (J. Phys. Chem.more » B 114, 298 (2010)). Furthermore, these high pressure and high temperature (HPHT) data with high precision firstly complement and close the gap between the resistive heating and the shock compression experiment.« less
Huang, Xiaoli; Li, Fangfei; Zhou, Qiang; ...
2016-02-17
Here we report that the equation of state (EOS) of Mo is obtained by an integrated technique of laser-heated DAC and synchrotron X-ray diffraction. The cold compression and thermal expansion of Mo have been measured up to 80 GPa at 300 K, and 92 GPa at 3470 K, respectively. The P-V-T data have been treated with both thermodynamic and Mie–Gruneisen-Debye methods for the thermal EOS inversion. The results are self-consistent and in agreement with the static multi-anvil compression data of Litasov et al. (J. Appl. Phys. 113, 093507 (2013)) and the theoretical data of Zeng et al. (J. Phys. Chem.more » B 114, 298 (2010)). Furthermore, these high pressure and high temperature (HPHT) data with high precision firstly complement and close the gap between the resistive heating and the shock compression experiment.« less
A retrospective review of burn dressings on a porcine burn model.
Wang, Xue-Qing; Kravchuk, Olena; Kimble, Roy M
2010-08-01
This is a study to compare wound healing among three types of dressings on a porcine model with deep-dermal-partial-thickness burns. The burns in this study were from eight animal trials conducted in the past for other purposes and only burns with a uniform pale appearance that had served as controls in original experiments were selected. In total, there were 57 burns in 33 pigs, using one of following three dressings: Acticoat (Silver) (3 trials), Jelonet (Gauze) (3 trials), and Solosite Gel/Jelonet (Gel/Gauze) (2 trials). The wound healing assessments included wound re-epithelialisation during a 6-week period, clinical and histological scar assessments at week 6 after burn. Of all wound healing/scar assessments, only re-epithelialisation showed statistical difference between dressings. Earlier re-epithelialisation was observed in Gel/Gauze dressings compared to Silver and/or Gauze dressings. However, this study revealed huge variation in wound healing outcome between 3 trials within both Silver and/or Gauze dressings, supported by significant differences on re-epithelialisation, clinical and histological scar measurements. In addition, it was found that larger animals healed better than smaller ones, based on weights from 21 pigs. Of all dressings, Silver delivers the best protection for wound colonization/infection. Wound colonization/infection was found to confine wound healing and lead to thinner RND in scars. From this study, we cannot find enough evidence to suggest the beneficial effect of one dressing(s) over others on burn wound healing outcome on a porcine model with small deep-dermal-partial-thickness burns with a relative small sample size.
Guo, Chunlan; Deng, Hongyan; Yang, Jian
2015-01-01
To assess the effect of virtual reality distraction on pain among patients with a hand injury undergoing a dressing change. Virtual reality distraction can effectively alleviate pain among patients undergoing a dressing change. Clinical research has not addressed pain control during a dressing change. A randomised controlled trial was performed. In the first dressing change sequence, 98 patients were randomly divided into an experimental group and a control group, with 49 cases in each group. Pain levels were compared between the two groups before and after the dressing change using a visual analog scale. The sense of involvement in virtual environments was measured using the Pearson correlation coefficient analysis, which determined the relationship between the sense of involvement and pain level. The difference in visual analog scale scores between the two groups before the dressing change was not statistically significant (t = 0·196, p > 0·05), but the scores became statistically significant after the dressing change (t = -30·792, p < 0·01). The correlation between the sense of involvement in a virtual environment and pain level during the dressing was statistically significant (R(2) = 0·5538, p < 0·05). Virtual reality distraction can effectively alleviate pain among patients with a hand injury undergoing a dressing change. Better results can be obtained by increasing the sense of involvement in a virtual environment. Virtual reality distraction can effectively relieve pain without side effects and is not reliant on a doctor's prescription. This tool is convenient for nurses to use, especially when analgesics are unavailable. © 2014 John Wiley & Sons Ltd.
Kelleher, Maureen E; Kilcoyne, Isabelle; Dechant, Julie E; Hummer, Emma; Kass, Philip H; Snyder, Jack R
2015-04-01
To determine if application of silver sodium zirconium phosphate polyurethane semi-occlusive foam (SPF) dressing would improve measures of wound healing and decrease bacterial contamination compared with a non-adherent, absorbent dressing applied to wounds created on the distal aspect of the equine limb. Controlled randomized experimental study. Adult Quarter Horse and Thoroughbred horses (n = 5). One 6.25 cm(2) wound was created on the dorsomedial aspect of the proximal metacarpus on each forelimb. A SPF dressing was applied to 1 randomly assigned limb as a treatment and a non-adherent, absorbent dressing was applied to the opposite limb as control. Bandages were changed every 3 days for 60 days. Granulation tissue was scored every 3 days, wound area measured every 6 days, and wound bed was cultured every 12 days. SPF-treatment wounds had significantly decreased wound area and decreased granulation tissue scores when evaluated <30 days and over the 60 day study, although complete wound healing times were not significantly different. Bacteria were cultured from all wounds at varying times throughout the study. The SPF wound dressing improved some measures of wound healing compared with the control dressing, most significantly during the first 30 days. This suggests that the SPF wound dressing may be useful in the early management of wounds on the equine lower limb. Further studies using the SPF dressing are needed to characterize the temporal and cellular effects on wound healing and evaluate this dressing in a clinical environment. © Copyright 2014 by The American College of Veterinary Surgeons.
Elsner, J J; Berdicevsky, I; Zilberman, M
2011-01-01
About 70% of all people with severe burns die from related infections, despite advances in treatment regimens and the best efforts of nurses and doctors. Although silver-eluting wound dressings are available for addressing this problem, there is growing evidence of the deleterious effects of such dressings in delaying the healing process owing to cellular toxicity. A new concept of antibiotic-eluting composite wound dressings is described here. These dressings are based on a polyglyconate mesh coated with a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with antibiotic drugs. The effect of antibiotic release on bacterial inhibition was studied, and cell cytotoxicity was examined. The dressings resulted in a 99.99% decrease in the viable counts of Pseudomonas aeruginosa and Staphylococcus albus at very high initial inoculations of 10⁷-10⁸ CFU ml⁻¹ after only 1 day, while such a decrease in Staphylococcus aureus was obtained within 3 days. Bacterial inhibition zones around the dressing material were found to persist for 2 weeks, indicating a long-lasting antimicrobial effect. Despite severe toxicity to bacteria, the dressing material was found to have no toxic effect on cultured fibroblasts, indicating that the new antibiotic-eluting wound dressings represent an effective option for selective treatment of bacterial infections. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wong, Wilson
The cold gas dynamic spraying of commercially pure titanium coatings was investigated. Specifically, the relationship between several key cold spray parameters on the quality of the resulting coatings was studied in order to gain a more thorough understanding of the cold spray process. To achieve this goal, three distinct investigations were performed. The first part of the investigation focussed on the effect of propelling gas, particularly helium and nitrogen, during the cold spraying of titanium coatings. Coatings were characterised by SEM and were evaluated for their deposition efficiency (DE), microhardness, and porosity. In selected conditions, three particle velocities were investigated such that for each condition, the propelling gasses temperature and pressure were attuned to attain similar particle velocities for each gas. In addition, a thick and fully dense cold sprayed titanium coating was achieved with optimised spray parameters and nozzle using helium. The corresponding average particle velocity was 1173 m/s. The second part of the investigation studied the effect of particle morphology (spherical, sponge, and irregular) and size distributions (mean particle sizes of 20, 29, and 36 mum) of commercially pure titanium on the mechanical properties of the resulting cold sprayed coatings. Numerous powder and coating characterisations were performed. From these data, semi-empirical flow (stress-strain) curves were generated based on the Johnson-Cook plasticity model which could be used as a measure of cold sprayability. Cold sprayability can be defined as the ease with which a powder can be cold sprayed. It was found that the sponge and irregular commercially pure titanium powders had higher oxygen content, poorer powder flowability, higher compression ratio, lower powder packing factor, and higher average particle impact velocities compared to the spherical powders. XRD results showed no new phases present when comparing the various feedstock powders to their corresponding coatings. For all feedstock powder morphologies, it was observed that the larger the particle size, the higher the temperature generated on impact. For the spherical powders, the higher the temperature generated on impact, the lower the stress needed to deform the particle. In addition, as the kinetic energy of the impacting particle increased, the flow peak stress decreased while the final strain increased. Furthermore, higher final flow strains were associated with higher coating DeltaHV 10 (between the coatings and the feedstock powders). Similar relationships are expected to exist for the sponge and irregular feedstock powders. Based on porosity, the spherical medium powder was found to have the best cold sprayability. The final part of the investigation focussed on the effect of substrate surface roughness and coating thickness on the adhesion strength of commercially pure titanium cold sprayed coatings onto Steel 1020, Al 6061, and Ti substrates. Adhesion strength was measured by tensile/pull tests according to ASTM C-633-01 standard. Through-thickness residual stresses of selected coatings were measured using the modified layer removal method (MLRM). In addition, mean coating residual stresses were calculated from MLRM results. It was found that adhesion strength increases with increasing substrate surface roughness and decreases with increasing coating thickness. Furthermore, mean coating residual stresses were correlated with adhesion strength and it was suggested that higher adhesion strengths are associated with higher mean compressive stresses and a higher probability for adiabatic shear instability to occur due to the higher particle impact velocities. In general, it was found that under similar cold spray conditions and substrate surface preparation method, adhesion strength was strongest for commercially pure titanium coatings deposited onto Al 6061, followed by Ti, then Steel 1020.
Matsumura, Hajime; Imai, Ryutaro; Ahmatjan, Niyaz; Ida, Yukiko; Gondo, Masahide; Shibata, Dai; Wanatabe, Katsueki
2014-02-01
In recent years, adhesive wound dressings have been increasingly applied postoperatively because of their ease of use as they can be kept in place without having to cut and apply surgical tapes and they can cover a wound securely. However, if a wound dressing strongly adheres to the wound, a large amount of stratum corneum is removed from the newly formed epithelium or healthy periwound skin. Various types of adhesives are used on adhesive wound dressings and the extent of skin damage depends on how much an adhesive sticks to the wound or skin surface. We quantitatively determined and compared the amount of stratum corneum removed by eight different wound dressings including polyurethane foam using acrylic adhesive, silicone-based adhesive dressing, composite hydrocolloid and self-adhesive polyurethane foam in healthy volunteers. The results showed that wound dressings with silicone adhesive and self-adhesive polyurethane foam removed less stratum corneum, whereas composite hydrocolloid and polyurethane foam using acrylic adhesive removed more stratum corneum. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
The Effect of Offloading Heels on Sacral Pressure.
Al-Majid, Sadeeka; Vuncanon, Barbara; Carlson, Nika; Rakovski, Cyril
2017-09-01
Offloading a patient's heels during supine surgical procedures is a common practice to prevent heel pressure injuries. This practice may increase sacral pressure and jeopardize sacral skin integrity, but prophylactic dressings may help protect sacral skin. The purpose of this study was to examine the effects of offloading the heels and of multilayered silicone foam dressings on sacral pressure. We measured the sacral pressure of 50 healthy volunteers using a pressure-mapping system under four conditions: heels not offloaded and sacral dressing applied, heels offloaded and dressing applied, heels not offloaded and no dressing, and heels offloaded and no dressing. We used linear mixed-effects modeling to compare the effects of these conditions on sacral pressure. Offloading the heels significantly increased sacral pressure (P < .001), whereas the dressing had no effect on sacral pressure (P = .49). Offloading a patient's heels may increase the risk of sacral pressure injuries. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.
A new postoperative otoplasty dressing technique using cyanoacrylate tissue adhesives.
Vetter, Miriam; Foehn, Matthias; Wedler, Volker
2010-04-01
There are many techniques for cosmetic surgery of the ears and also many different procedures for postoperative treatment. The postoperative dressing is described as important for a successful outcome. We present our method of postoperative dressing in the form of liquid bonding. Cyanoacrylate tissue adhesives as liquid bonding agents are used for fixation of the pinna at the mastoid area. After 10-14 days the bonding can be easily removed. No huge dressings, tapes, or plasters are necessary. The patients are satisfied with the light dressing; they do not feel ashamed to appear in public. We have found this dressing technique to be simple and economical, especially because of the use of the bonding for skin closure before. It can be used after otoplasty with an anterior or a posterior approach.
Dressed Wilson loops as dual condensates in response to magnetic and electric fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruckmann, Falk; Endroedi, Gergely
2011-10-01
We introduce dressed Wilson loops as a novel confinement observable. It consists of closed planar loops of arbitrary geometry but fixed area, and its expectation values decay with the latter. The construction of dressed Wilson loops is based on chiral condensates in response to magnetic and electric fields, thus linking different physical concepts. We present results for generalized condensates and dressed Wilson loops on dynamical lattice configurations and confirm the agreement with conventional Wilson loops in the limit of large probe mass. We comment on the renormalization of dressed Wilson loops.
The role of dressings in the prevention of pressure ulcers.
Brown, Julie
2016-08-11
Pressure ulceration is a significant global healthcare problem and represents a considerable burden on healthcare resources. Within the literature an increasing number of studies have examined the role prophylactic dressings play in redistributing pressure and helping to protect the skin from the effects of friction and shear. The use of dressings to prevent pressure ulcers may be considered a controversial issue, as previous opinion has been that dressings do not reduce the effects of pressure. This article will critically evaluate the literature to examine the role dressings play in the prevention of pressure ulceration.
Foam dressings for treating pressure ulcers.
Walker, Rachel M; Gillespie, Brigid M; Thalib, Lukman; Higgins, Niall S; Whitty, Jennifer A
2017-10-12
Pressure ulcers, also known as pressure injuries and bed sores, are localised areas of injury to the skin or underlying tissues, or both. Dressings made from a variety of materials, including foam, are used to treat pressure ulcers. An evidence-based overview of dressings for pressure ulcers is needed to enable informed decision-making on dressing use. This review is part of a suite of Cochrane Reviews investigating the use of dressings in the treatment of pressure ulcers. Each review will focus on a particular dressing type. To assess the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers in people with an existing pressure ulcer in any care setting. In February 2017 we searched: the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations); Ovid Embase; EBSCO CINAHL Plus and the NHS Economic Evaluation Database (NHS EED). We also searched clinical trials registries for ongoing and unpublished studies, and scanned reference lists of relevant included studies as well as reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. Published or unpublished randomised controlled trials (RCTs) and cluster-RCTs, that compared the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers (Category/Stage II or above). Two review authors independently performed study selection, risk of bias and data extraction. A third reviewer resolved discrepancies between the review authors. We included nine trials with a total of 483 participants, all of whom were adults (59 years or older) with an existing pressure ulcer Category/Stage II or above. All trials had two arms, which compared foam dressings with other dressings for treating pressure ulcers.The certainty of evidence ranged from low to very low due to various combinations of selection, performance, attrition, detection and reporting bias, and imprecision due to small sample sizes and wide confidence intervals. We had very little confidence in the estimate of effect of included studies. Where a foam dressing was compared with another foam dressing, we established that the true effect was likely to be substantially less than the study's estimated effect.We present data for four comparisons.One trial compared a silicone foam dressing with another (hydropolymer) foam dressing (38 participants), with an eight-week (short-term) follow-up. It was uncertain whether alternate types of foam dressing affected the incidence of healed pressure ulcers (RR 0.89, 95% CI 0.45 to 1.75) or adverse events (RR 0.37, 95% CI 0.04 to 3.25), as the certainty of evidence was very low, downgraded for serious limitations in study design and very serious imprecision.Four trials with a median sample size of 20 participants (230 participants), compared foam dressings with hydrocolloid dressings for eight weeks or less (short-term). It was uncertain whether foam dressings affected the probability of healing in comparison to hydrocolloid dressings over a short follow-up period in three trials (RR 0.85, 95% CI 0.54 to 1.34), very low-certainty evidence, downgraded for very serious study limitations and serious imprecision. It was uncertain if there was a difference in risk of adverse events between groups (RR 0.88, 95% CI 0.37 to 2.11), very low-certainty evidence, downgraded for serious study limitations and very serious imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but we assessed the evidence as being of very low certainty.One trial (34 participants), compared foam and hydrogel dressings over an eight-week (short-term) follow-up. It was uncertain if the foam dressing affected the probability of healing (RR 1.00, 95% CI 0.78 to 1.28), time to complete healing (MD 5.67 days 95% CI -4.03 to 15.37), adverse events (RR 0.33, 95% CI 0.01 to 7.65) or reduction in ulcer size (MD 0.30 cm 2 per day, 95% CI -0.15 to 0.75), as the certainty of the evidence was very low, downgraded for serious study limitations and very serious imprecision.The remaining three trials (181 participants) compared foam with basic wound contact dressings. Follow-up times ranged from short-term (8 weeks or less) to medium-term (8 to 24 weeks). It was uncertain whether foam dressings affected the probability of healing compared with basic wound contact dressings, in the short term (RR 1.33, 95% CI 0.62 to 2.88) or medium term (RR 1.17, 95% CI 0.79 to 1.72), or affected time to complete healing in the medium term (MD -35.80 days, 95% CI -56.77 to -14.83), or adverse events in the medium term (RR 0.58, 95% CI 0.33 to 1.05). This was due to the very low-certainty evidence, downgraded for serious to very serious study limitations and imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but again, we assessed the evidence as being of very low certainty.None of the included trials reported quality of life or pressure ulcer recurrence. It is uncertain whether foam dressings are more clinically effective, more acceptable to users, or more cost effective compared to alternative dressings in treating pressure ulcers. It was difficult to make accurate comparisons between foam dressings and other dressings due to the lack of data on reduction of wound size, complete wound healing, treatment costs, or insufficient time-frames. Quality of life and patient (or carer) acceptability/satisfaction associated with foam dressings were not systematically measured in any of the included studies. We assessed the certainty of the evidence in the included trials as low to very low. Clinicians need to carefully consider the lack of robust evidence in relation to the clinical and cost-effectiveness of foam dressings for treating pressure ulcers when making treatment decisions, particularly when considering the wound management properties that may be offered by each dressing type and the care context.
Ullman, Amanda J; Kleidon, Tricia; Gibson, Victoria; McBride, Craig A; Mihala, Gabor; Cooke, Marie; Rickard, Claire M
2017-08-30
Central venous access device (CVAD) associated complications are a preventable source of patient harm, frequently resulting in morbidity and delays to vital treatment. Dressing and securement products are used to prevent infectious and mechanical complications, however current complication rates suggest customary practices are inadequate. The aim of this study was to evaluate the feasibility of launching a full-scale randomized controlled efficacy trial of innovative dressing and securement products for pediatric tunneled CVAD to prevent complication and failure. An external, pilot, four-group randomized controlled trial of standard care (bordered polyurethane dressing and suture), in comparison to integrated securement-dressing, suture-less securement device, and tissue adhesive was undertaken across two large, tertiary referral pediatric hospitals in Australia. Forty-eight pediatric participants with newly inserted tunneled CVADs were consecutively recruited. The primary outcome of study feasibility was established by elements of eligibility, recruitment, attrition, protocol adherence, missing data, parent and healthcare staff satisfaction and acceptability, and effect size estimates for CVAD failure (cessation of function prior to completion of treatment) and complication (associated bloodstream infection, thrombosis, breakage, dislodgement or occlusion). Dressing integrity, product costs and site complications were also examined. Protocol feasibility was established. CVAD failure was: 17% (2/12) integrated securement-dressing; 8% (1/13) suture-less securement device; 0% tissue adhesive (0/12); and, 0% standard care (0/11). CVAD complications were: 15% (2/13) suture-less securement device (CVAD associated bloodstream infection, and occlusion and partial dislodgement); 8% (1/12) integrated securement-dressing (partial dislodgement); 0% tissue adhesive (0/12); and, 0% standard care (0/11). One CVAD-associated bloodstream infection occurred, within the suture-less securement device group. Overall satisfaction was highest in the integrated securement-dressing (mean 8.5/10; standard deviation 1.2). Improved dressing integrity was evident in the intervention arms, with the integrated securement-dressing associated with prolonged time to first dressing change (mean days 3.5). Improving the security and dressing integrity of tunneled CVADs is likely to improve outcomes for pediatric patients. Further research is necessary to identify novel, effective CVAD securement to reduce complications, and provide reliable vascular access for children. ACTRN12614000280606 ; prospectively registered on 17/03/2014.
In a 21-2n deformed stainless steel influence of recovery temperature
NASA Astrophysics Data System (ADS)
De Ita, A.; Ugalde, P.; Flores, D.
2017-01-01
We present the influence high heat treatment temperature of a nitrogen austenitic stainless steel, deform by cold compression, in 10 different percentages. The steel contains high chromium (19.25 %), nickel (1.5 %) and nitrogen (0.2 %). The typical applications for this alloy are automobile parts and special valves for his excellent mechanical properties and corrosion resistance. Produced by hot rolling, they were subjected homogenized treatment at 975 °C for 45 minutes. Subsequently, deformed, by cold compression. We get ten different deformations, from 3 % to 22 %. These samples then to a heat treatment at 750 °C for one, 2 and 4 hours respectively. To observe the microstructure all samples were metallographic study and measured also their Rockwell C hardness. The initial sample has an austenitic matrix with a small amount of precipitates with a 42 RC average hardness. The homogenized sample had a 39 RC hardness. The deformed samples increased their hardness with a maximum of 49 RC. The samples with the treatment, showed a lower hardness with longer time with high dispersion. The decreased of hardness is due to the elimination of residual stresses and precipitates increasing size.
Microstructure and mechanical properties of an ultrafine Ti–Si–Nb alloy
Cao, G. H.; Jian, G. Y.; Liu, N.; ...
2015-08-19
In this study, Nb-modified ultrafine Ti–Si eutectic alloy was made by cold crucible levitation melting, tested in compression at room temperature, and characterized by electron microscopy. Compression tests of (Ti 86.5Si 13.5) 97Nb 3 specimens measured an ultimate compressive strength of 1180 MPa and a compressive plastic strain of 12%, both of which are higher than in eutectic Ti 86.5Si 13.5 alloy. Electron microscopy showed that the Ti–Si–Nb alloy had a bimodal microstructure with micrometer-scale primary α-Ti dendrites distributed in an ultrafine eutectic (α-Ti + Ti 5Si 3) matrix. The enhanced ductility is attributed to the morphology of the phase constituents and to the larger lattice mismatches between α-Ti and Ti 5Si 3 phases caused by the Nb addition. The crystallographic orientation relationship of Ti 5Si 3 with α-Ti is (more » $$1\\bar{1}00$$)[$$\\overline{11}$$26]Ti 5Si 3∥($$01\\bar{1}1$$)[5$$\\overline{143}$$] α–Τi.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, L. J.; Logan, B. G.; Zimmerman, G. B.
2013-07-15
We report for the first time on full 2-D radiation-hydrodynamic implosion simulations that explore the impact of highly compressed imposed magnetic fields on the ignition and burn of perturbed spherical implosions of ignition-scale cryogenic capsules. Using perturbations that highly convolute the cold fuel boundary of the hotspot and prevent ignition without applied fields, we impose initial axial seed fields of 20–100 T (potentially attainable using present experimental methods) that compress to greater than 4 × 10{sup 4} T (400 MG) under implosion, thereby relaxing hotspot areal densities and pressures required for ignition and propagating burn by ∼50%. The compressed fieldmore » is high enough to suppress transverse electron heat conduction, and to allow alphas to couple energy into the hotspot even when highly deformed by large low-mode amplitudes. This might permit the recovery of ignition, or at least significant alpha particle heating, in submarginal capsules that would otherwise fail because of adverse hydrodynamic instabilities.« less
Ionization impact on molecular clouds and star formation. Numerical simulations and observations
NASA Astrophysics Data System (ADS)
Tremblin, P.
2012-11-01
At all the scales of Astrophysics, the impact of the ionization from massive stars is a crucial issue. At the galactic scale, the ionization can regulate star formation by supporting molecular clouds against gravitational collapse and at the stellar scale, indications point toward a possible birth place of the Solar System close to massive stars. At the molecular cloud scale, it is clear that the hot ionized gas compresses the surrounding cold gas, leading to the formation of pillars, globules, and shells of dense gas in which some young stellar objects are observed. What are the formation mechanisms of these structures? Are the formation of these young stellar objects triggered or would have they formed anyway? Do massive stars have an impact on the distribution of the surrounding gas? Do they have an impact on the mass distribution of stars (the initial mass function, IMF)? This thesis aims at shedding some light on these questions, by focusing especially on the formation of the structures between the cold and the ionized gas. We present the state of the art of the theoretical and observational works on ionized regions (H ii regions) and we introduce the numerical tools that have been developed to model the ionization in the hydrodynamic simulations with turbulence performed with the HERACLES code. Thanks to the simulations, we present a new model for the formation of pillars based on the curvature and collapse of the dense shell on itself and a new model for the formations of cometary globules based on the turbulence of the cold gas. Several diagnostics have been developed to test these new models in the observations. If pillars are formed by the collapse of the dense shell on itself, the velocity spectrum of a nascent pillar presents a large spectra with a red-shifted and a blue-shifted components that are caused by the foreground and background parts of the shell that collapse along the line of sight. If cometary globules emerge because of the turbulence of the molecular cloud, the velocity spectrum of these globules is shifted at different velocities than the velocity of the shell, pillars and clumps that follow the global expansion of the H ii region. An other diagnostic is the impact of the compression on the probability density function (PDF) of the cold gas. The distribution is double peaked when the turbulent ram pressure is low compared to the ionized-gas pressure. This is the signature of the compression caused by the expansion of the ionized bubble. When the turbulence is high, the two peaks merge and the compression can still be identified although the signature is less clear. We have used Herschel column density maps and molecular-line data to characterize the density and velocity structures of the interface between the ionized and the cold gas in several regions: RCW 120, RCW 36, Cygnus X, the Rosette and Eagle Nebulae. In addition to the diagnostics derived from the simulations, analytical predictions of the shell and pillar parameters was tested and confronted to the observations. In all the regions, we have seen that there is a good agreement with the analytical models and with the simulation diagnostics. The velocity structure of a nascent pillar in the Rosette Nebula suggests that it has been formed by the collapse of the shell on itself and the bulk velocity of cometary globules in Cygnus X and in the Rosette Nebula tends to confirm their turbulent origin. The compression caused by the ionized gas can be seen on the PDF of the cold gas in most of the regions studied. This result is important for the link between the IMF and the global prop! erties of the cloud. If the IMF can be derived from the PDF of a cloud, the impact of the massive stars on the PDF has to be taken in account. Furthermore, we present dedicated simulations of RCW 36 that suggest that the dense clumps at the edge of the ionized gas are not pre-existing, it is likely that their formation was triggered by the compression caused by the ionization. Therefore the ionization from the massive stars is a key process that has to be taken into account for the understanding of the IMF. We also present in appendix other works that have been done in parallel of this thesis: the charge exchange in colliding planetary and stellar winds in collaboration with Prof. E. Chiang during the ISIMA summer school 2011 in Beijing; and the sub-millimeter site testing at the Concordia station in Antarctica with the CAMISTIC team.
Percutaneous urinary procedures - discharge
... a shower if you wrap the dressing with plastic wrap and replace the dressing if it gets ... include: Telfa (the dressing material), Tegaderm (the clear plastic tape that holds the plastic ring in place), ...
Fries, C A; Ayalew, Y; Penn-Barwell, J G; Porter, K; Jeffery, S L A; Midwinter, M J
2014-07-01
Recent conflicts have been characterised by the use of improvised explosive devices causing devastating injuries, including heavily contaminated wounds requiring meticulous surgical debridement. After being rendered surgical clean, these wounds are dressed and the patient transferred back to the UK for on-going treatment. A dressing that would prevent wounds from becoming colonised during transit would be desirable. The aim of this study was to establish whether using nanocrystalline silver dressings, as an adjunct to the initial debridement, would positively affect wound microbiology and wound healing compared to standard plain gauze dressings. Patients were prospectively randomised to receive either silver dressings, in a nanocrystalline preparation (Acticoat™), or standard of care dressings (plain gauze) following their initial debridement in the field hospital. On repatriation to the UK microbiological swabs were taken from the dressing and the wound, and an odour score recorded. Wounds were followed prospectively and time to wound healing was recorded. Additionally, patient demographic data were recorded, as well as the mechanism of injury and Injury Severity Score. 76 patients were recruited to the trial between February 2010 and February 2012. 39 received current dressings and 37 received the trial dressings. Eleven patients were not swabbed. There was no difference (p=0.1384, Fishers) in the primary outcome measure of wound colonisation between the treatment arm (14/33) and the control arm (20/32). Similarly time to wound healing was not statistically different (p=0.5009, Mann-Whitney). Wounds in the control group were scored as being significantly more malodorous (p=0.002, Mann-Whitney) than those in the treatment arm. This is the first randomised controlled trial to report results from an active theatre of war. Performing research under these conditions poses additional challenges to military clinicians. Meticulous debridement of wounds remains the critical determinant in wound healing and infection and this study did not demonstrate a benefit of nanocrystaline silver dressing in respect to preventing wound colonisation or promoting healing, these dressings do however seem to significantly reduce the unpleasant odour commonly associated with battlefield wounds. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Khodaei, Mohammad; Fathi, Mohammadhossein; Meratian, Mahmood; Savabi, Omid
2018-05-01
Reducing the elastic modulus and also improving biological fixation to the bone is possible by using porous scaffolds. In the present study, porous titanium scaffolds containing different porosities were fabricated using the space holder method. Pore distribution, formed phases and mechanical properties of titanium scaffolds were studied by Scanning Electron Microscope (SEM), x-ray diffraction (XRD) and cold compression test. Then the results of compression test were compared to the Gibson-Ashby model. Both experimentally measured and analytically calculated elastic modulus of porous titanium scaffolds decreased by porosity increment. The compliance between experimentally measured and analytically calculated elastic modulus of titanium scaffolds are also increased by porosity increment.
Bernatchez, Stéphanie F.; Ruckly, Stéphane; Timsit, Jean-François
2015-01-01
Objective To model the cost-effectiveness impact of routine use of an antimicrobial chlorhexidine gluconate-containing securement dressing compared to non-antimicrobial transparent dressings for the protection of central vascular lines in intensive care unit patients. Design This study uses a novel health economic model to estimate the cost-effectiveness of using the chlorhexidine gluconate dressing versus transparent dressings in a French intensive care unit scenario. The 30-day time non-homogeneous markovian model comprises eight health states. The probabilities of events derive from a multicentre (12 French intensive care units) randomized controlled trial. 1,000 Monte Carlo simulations of 1,000 patients per dressing strategy are used for probabilistic sensitivity analysis and 95% confidence intervals calculations. The outcome is the number of catheter-related bloodstream infections avoided. Costs of intensive care unit stay are based on a recent French multicentre study and the cost-effectiveness criterion is the cost per catheter-related bloodstream infections avoided. The incremental net monetary benefit per patient is also estimated. Patients 1000 patients per group simulated based on the source randomized controlled trial involving 1,879 adults expected to require intravascular catheterization for 48 hours. Intervention Chlorhexidine Gluconate-containing securement dressing compared to non-antimicrobial transparent dressings. Results The chlorhexidine gluconate dressing prevents 11.8 infections /1,000 patients (95% confidence interval: [3.85; 19.64]) with a number needed to treat of 85 patients. The mean cost difference per patient of €141 is not statistically significant (95% confidence interval: [€-975; €1,258]). The incremental cost-effectiveness ratio is of €12,046 per catheter-related bloodstream infection prevented, and the incremental net monetary benefit per patient is of €344.88. Conclusions According to the base case scenario, the chlorhexidine gluconate dressing is more cost-effective than the reference dressing. Trial Registration This model is based on the data from the RCT registered with www.clinicaltrials.gov (NCT01189682). PMID:26086783
Desroche, N; Dropet, C; Janod, P; Guzzo, J
2016-10-02
This study was designed to evaluate the antibacterial activity of a wound dressing which combines polyacrylate fibres and a silver lipido-colloid matrix (UrgoClean Ag, silver polyabsorbent dressing), against biofilm of methicillin-resistant Staphylococcus aureus (MRSA). Samples of silver polyabsorbent dressing and the neutral form of this dressing (UrgoClean) were applied to biofilms of MRSA formed on a collagen I-coated surface, cultured for 24 hours. Different exposure times were tested (1, 2, 4 and 7 days) without dressing change. The biofilm reduction was quantified by using culture methods and by confocal laser scanning microscopy experiments. The application of the silver polyabsorbent dressing resulted in a significant decrease of the biofilm population by a log reduction of 4.6, after 24 hours of exposure. Moreover, the antibiofilm activity was maintained for 7 days with reduction values up to 4 log (reduction of biofilm superior to 99.99%). The application of the neutral dressing also induced a significant reduction of the concentration of sessile cells after 1 day (about 0.90 log). The results obtained with this neutral form of the dressing showed that the polyacrylate fibres were able to exert a mechanical disruption of the biofilm architecture. These in vitro experiments demonstrated that silver polyabsorbent dressing was able to strongly reduce the biofilm of MRSA. The antibiofilm mechanism of this dressing can be explained by a dual action of the polyabsorbent fibres (based on ammonium polyacrylate polymer around an acrylic core) which induced a mechanical disruption of the biofilm matrix and/or a sequestration of sessile cells, and the diffusion of silver ions which produced bactericidal activity. This study was supported by Laboratoires Urgo (Dijon). P. Janod is an employee of Laboratoires Urgo. The company had no influence on the experimental design and the interpretation of the results.
2010-01-01
Background The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. Methods In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Results Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Conclusions Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing. PMID:20576085
Nasir, Nur-Azida Mohd; Halim, Ahmad Sukari; Singh, Kirnpal-Kaur Banga; Dorai, Ananda Aravazhi; Haneef, Mehru-Nisha Muhammad
2010-06-24
The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing.
Konstantatos, A H; Angliss, M; Costello, V; Cleland, H; Stafrace, S
2009-06-01
Pain arising in burns sufferers is often severe and protracted. The prospect of a dressing change can heighten existing pain by impacting both physically and psychologically. In this trial we examined whether pre-procedural virtual reality guided relaxation added to patient controlled analgesia with morphine reduced pain severity during awake dressings changes in burns patients. We conducted a prospective randomized clinical trial in all patients with burns necessitating admission to a tertiary burns referral centre. Eligible patients requiring awake dressings changes were randomly allocated to single use virtual reality relaxation plus intravenous morphine patient controlled analgesia (PCA) infusion or to intravenous morphine patient controlled analgesia infusion alone. Patients rated their worst pain intensity during the dressing change using a visual analogue scale. The primary outcome measure was presence of 30% or greater difference in pain intensity ratings between the groups in estimation of worst pain during the dressing change. Of 88 eligible and consenting patients having awake dressings changes, 43 were assigned to virtual reality relaxation plus intravenous morphine PCA infusion and 43 to morphine PCA infusion alone. The group receiving virtual reality relaxation plus morphine PCA infusion reported significantly higher pain intensities during the dressing change (mean=7.3) compared with patients receiving morphine PCA alone (mean=5.3) (p=0.003) (95% CI 0.6-2.8). The addition of virtual reality guided relaxation to morphine PCA infusion in burns patients resulted in a significant increase in pain experienced during awake dressings changes. In the absence of a validated predictor for responsiveness to virtual reality relaxation such a therapy cannot be recommended for general use in burns patients having awake dressings changes.
Dhillon, M; Carter, C P; Morrison, J; Hislop, W S; Currie, W J R
2015-06-01
The success of skin grafting is dependent on the interplay between many factors including nutrient uptake and vascular in-growth. To allow this, it is important that the graft is immobile and traditionally a 'pressure dressing' has been placed over the graft to improve outcome and graft 'take'. We present the findings of our comparative study of full-thickness skin grafts performed in the head, neck and face region over a period of 24 months. We felt that there was an unacceptably high infection rate and graft failure using pressure dressings. Data was collected retrospectively from the case notes on 70 patients who had undergone full-thickness skin grafting to the head, neck and face over a 2 year period. Thirty-five patients underwent grafting with pressure dressing and 35 without. The group with the pressure dressing had the same 'bolster' specification-type dressing and those without had their graft 'quilted' in and chloramphenicol ointment applied topically. Success was determined by the percentage 'take' of the grafts and absence of infection i.e. purulence. Infection in those with a pressure dressing stood at 26 % in contrast to those without, at 9 %. Without a pressure dressing we observed no total graft failures, compared to 6 % in those with a pressure dressing. The results confirmed the perception that there was a higher infection and graft failure rate where a pressure dressing was applied; however, this was not a statistically significant difference and a randomised control trial with a larger sample size would be required to validate the results.
Leaper, David; Nazir, Jameel; Roberts, Chris; Searle, Richard
2010-01-01
In patients at risk of surgical site infection (SSI), there is evidence that an antimicrobial barrier dressing (Acticoat* ) applied immediately post-procedure is effective in reducing the incidence of infection. The objective of this study was to assess when it is appropriate to use an antimicrobial barrier dressing rather than a post-operative film dressing, by evaluating the net cost and budget impact of the two strategies. An economic model was developed, which estimates expected expenditure on dressings and the expected costs of surgical site infection during the initial inpatient episode, based on published literature on the pre-discharge costs of surgical infection and the efficacy of an antimicrobial barrier dressing in preventing SSI. At an SSI risk of 10%, an antimicrobial barrier dressing strategy is cost neutral if the incidence of infection is reduced by at least 9% compared with a post-operative film dressing. At 35% efficacy, expenditure on dressings would be higher by £30,760 per 1000 patients, and the cost of treating infection would be lower by £111,650, resulting in a net cost saving of £80,890. The break-even infection risk for cost neutrality is 2.6%. Although this cost analysis is based on published data, there are limitations in methodology: the model is dependent on and subject to the limitations of the data used to populate it. Further studies would be useful to increase the robustness of the conclusions, particularly in a broader range of surgical specialties. A strategy involving the use of an antimicrobial barrier dressing in patients at moderate (5-10%) or high (>10%) risk of infection appears reasonable and cost saving in light of the available clinical evidence.
Zaller, Johann G; König, Nina; Tiefenbacher, Alexandra; Muraoka, Yoko; Querner, Pascal; Ratzenböck, Andreas; Bonkowski, Michael; Koller, Robert
2016-08-17
Seed dressing with pesticides is widely used to protect crop seeds from pest insects and fungal diseases. While there is mounting evidence that especially neonicotinoid seed dressings detrimentally affect insect pollinators, surprisingly little is known on potential side effects on soil biota. We hypothesized that soil organisms would be particularly susceptible to pesticide seed dressings as they get in direct contact with these chemicals. Using microcosms with field soil we investigated, whether seeds treated either with neonicotinoid insecticides or fungicides influence the activity and interaction of earthworms, collembola, protozoa and microorganisms. The full-factorial design consisted of the factor Seed dressing (control vs. insecticide vs. fungicide), Earthworm (no earthworms vs. addition Lumbricus terrestris L.) and collembola (no collembola vs. addition Sinella curviseta Brook). We used commercially available wheat seed material (Triticum aesticum L. cf. Lukullus) at a recommended seeding density of 367 m(-2). Seed dressings (particularly fungicides) increased collembola surface activity, increased the number of protozoa and reduced plant decomposition rate but did not affect earthworm activity. Seed dressings had no influence on wheat growth. Earthworms interactively affected the influence of seed dressings on collembola activity, whereas collembola increased earthworm surface activity but reduced soil basal respiration. Earthworms also decreased wheat growth, reduced soil basal respiration and microbial biomass but increased soil water content and electrical conductivity. The reported non-target effects of seed dressings and their interactions with soil organisms are remarkable because they were observed after a one-time application of only 18 pesticide treated seeds per experimental pot. Because of the increasing use of seed dressing in agriculture and the fundamental role of soil organisms in agroecosystems these ecological interactions should receive more attention.
Toon, Clare D; Lusuku, Charnelle; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2015-09-03
Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In March 2015 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.
Toon, Clare D; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2013-09-05
Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In July 2013 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.
Pediatric Digital Necrosis Secondary to Dressing Application: A Case Series.
Bjorklund, Kim A; Rice, Dahlia M; Amalfi, Ashley N
2018-04-01
Pediatric digital necrosis resulting in revision amputation is a devastating outcome following digital dressing application. We report a series of 4 pediatric patients (age: 21 months-11 years) who presented for surgical consultation related to digital ischemia and irreversible necrosis following the application of Coban digital dressings. A review of the literature demonstrated that such injuries had not previously been described. In our case series, Coban dressing was utilized as a deterrent for thumb sucking, fingertip tuft fractures with nail bed lacerations, and a phalanx fracture secondary to crush injury. All 4 children suffered digital necrosis secondary to Coban dressings and ultimately required revision amputation. We discuss risks factors, application practices, and strategies to minimize complications with digital dressings in the pediatric population with the intent of creating awareness among hand surgeons to help promote safe practices and improve patient outcomes.
Enhancing pressure ulcer prevention using wound dressings: what are the modes of action?
Call, Evan; Pedersen, Justin; Bill, Brian; Black, Joyce; Alves, Paulo; Brindle, C Tod; Dealey, Carol; Santamaria, Nick; Clark, Michael
2015-08-01
Recent clinical research has generated interest in the use of sacral wound dressings as preventive devices for patients at risk of ulceration. This study was conducted to identify the modes of action through which dressings can add to pressure ulcer prevention, for example, shear and friction force redistribution and pressure distribution. Bench testing was performed using nine commercially available dressings. The use of dressings can reduce the amplitude of shear stress and friction reaching the skin of patients at risk. They can also effectively redirect these forces to wider areas which minimises the mechanical loads upon skeletal prominences. Dressings can redistribute pressure based upon their effective Poisson ratio and larger deflection areas, providing greater load redistribution. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Heffernan, A; Martin, A J
1994-01-01
A clinical study of 96 patients compared a new hydrocolloid dressing (Granuflex Extra Thin) with a non-adherent dressing (perforated film absorbent dressing) in the management of lacerations, abrasions and minor operation incisions at the Accident and Emergency (A&E) Department of the University College Hospital, Galway. While time to heal was similar for both groups, the patients using Granuflex Extra Thin experienced less pain (P < 0.001), required less analgesia (P = 0.0154) and were able to carry out their normal daily activities including bathing or showering without affecting the dressing or the wound. Patient satisfaction with the new dressing appeared to be very high especially in those patients who pursued an active lifestyle. PMID:7894807
Elsner, Jonathan J; Egozi, Dana; Ullmann, Yehuda; Berdicevsky, Israela; Shefy-Peleg, Adaya; Zilberman, Meital
2011-08-01
Approximately 70% of all people with severe burns die from related infections despite advances in treatment regimens and the best efforts of nurses and doctors. Silver ion-eluting wound dressings are available for overcoming this problem. However, there are reports of deleterious effects of such dressings due to cellular toxicity that delays the healing process, and the dressing changes needed 1-2 times a day are uncomfortable for the patient and time consuming for the stuff. An alternative concept in wound dressing design that combines the advantages of occlusive dressings with biodegradability and intrinsic topical antibiotic treatment is described herewith. The new composite structure presented in this article is based on a polyglyconate mesh and a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with gentamicin developed to provide controlled release of antibiotics for three weeks. In vivo evaluation of the dressing material in contaminated deep second degree burn wounds in guinea pigs (n=20) demonstrated its ability to accelerate epithelialization by 40% compared to an unloaded format of the material and a conventional dressing material. Wound contraction was reduced significantly, and a better quality scar tissue was formed. The current dressing material exhibits promising results, does not require frequent bandage changes, and offers a potentially valuable and economic approach to treating the life-threatening complication of burn-related infections. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Release of antibiotics from collagen dressing.
Grzybowski, J; Antos-Bielska, M; Ołdak, E; Trafny, E A
1997-01-01
Our new collagen dressing has been developed recently. Three types (A, B, and C) of the dressing were prepared in this study. Each type contained bacitracin, neomycin or colistin. The antibiotic was input into: i. collagen sponge (CS)--type A, ii. layer of limited hydrophobicity (LLH)--type B, and iii. into both CS and LLH layers--type C. The final concentration of the antibiotic that resulted from the loading level was 2 mg/cm2 for the dressings of type A and B and 4 mg/cm2 for the dressing of type C. The antibiotics were then extracted from the pieces of dressings for two days through dialysis membrane. Susceptibility of 54 bacterial strains (S. aureus, P. aeruginosa, and Acinetobacter) isolated from burn wounds were tested to the three antibiotics used for preparation of the dressings. The results of the study evidenced that efficiency of released of antibiotics into the extracts depended on the kind of antibiotic and on the type of dressing. The concentration of the antibiotics proved to be much higher than MIC90 values of the bacterial isolates tested in respect to their susceptibility. The dressing containing mixture of the three antibiotics in two layers--CS and LLH is now considered as potentially effective for care of infected wounds. It may be useful for the treatment of infected wounds or for profilaxis of contaminated wounds, ensuring: i. sufficient antimicrobial activity in wound, and ii. optimal wound environment for the presence of collagenic biomaterial on the damaged tissue.
Cold-water immersion (cryotherapy) for preventing and treating muscle soreness after exercise.
Bleakley, Chris; McDonough, Suzanne; Gardner, Evie; Baxter, G David; Hopkins, J Ty; Davison, Gareth W
2012-02-15
Many strategies are in use with the intention of preventing or minimising delayed onset muscle soreness and fatigue after exercise. Cold-water immersion, in water temperatures of less than 15°C, is currently one of the most popular interventional strategies used after exercise. To determine the effects of cold-water immersion in the management of muscle soreness after exercise. In February 2010, we searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (The Cochrane Library (2010, Issue 1), MEDLINE, EMBASE, Cumulative Index to Nursing and Allied Health (CINAHL), British Nursing Index and archive (BNI), and the Physiotherapy Evidence Database (PEDro). We also searched the reference lists of articles, handsearched journals and conference proceedings and contacted experts.In November 2011, we updated the searches of CENTRAL (2011, Issue 4), MEDLINE (up to November Week 3 2011), EMBASE (to 2011 Week 46) and CINAHL (to 28 November 2011) to check for more recent publications. Randomised and quasi-randomised trials comparing the effect of using cold-water immersion after exercise with: passive intervention (rest/no intervention), contrast immersion, warm-water immersion, active recovery, compression, or a different duration/dosage of cold-water immersion. Primary outcomes were pain (muscle soreness) or tenderness (pain on palpation), and subjective recovery (return to previous activities without signs or symptoms). Three authors independently evaluated study quality and extracted data. Some of the data were obtained following author correspondence or extracted from graphs in the trial reports. Where possible, data were pooled using the fixed-effect model. Seventeen small trials were included, involving a total of 366 participants. Study quality was low. The temperature, duration and frequency of cold-water immersion varied between the different trials as did the exercises and settings. The majority of studies failed to report active surveillance of pre-defined adverse events.Fourteen studies compared cold-water immersion with passive intervention. Pooled results for muscle soreness showed statistically significant effects in favour of cold-water immersion after exercise at 24 hour (standardised mean difference (SMD) -0.55, 95% CI -0.84 to -0.27; 10 trials), 48 hour (SMD -0.66, 95% CI -0.97 to -0.35; 8 trials), 72 hour (SMD -0.93; 95% CI -1.36 to -0.51; 4 trials) and 96 hour (SMD -0.58; 95% CI -1.00 to -0.16; 5 trials) follow-ups. These results were heterogeneous. Exploratory subgroup analyses showed that studies using cross-over designs or running based exercises showed significantly larger effects in favour of cold-water immersion. Pooled results from two studies found cold-water immersion groups had significantly lower ratings of fatigue (MD -1.70; 95% CI -2.49 to -0.90; 10 units scale, best to worst), and potentially improved ratings of physical recovery (MD 0.97; 95% CI -0.10 to 2.05; 10 units scale, worst to best) immediately after the end of cold-water immersion.Five studies compared cold-water with contrast immersion. Pooled data for pain showed no evidence of differences between the two groups at four follow-up times (immediately, 24, 48 and 72 hours after treatment). Similar findings for pooled analyses at 24, 48 and 72 hour follow-ups applied to the four studies comparing cold-water with warm-water immersion. Single trials only compared cold-water immersion with respectively active recovery, compression and a second dose of cold-water immersion at 24 hours. There was some evidence that cold-water immersion reduces delayed onset muscle soreness after exercise compared with passive interventions involving rest or no intervention. There was insufficient evidence to conclude on other outcomes or for other comparisons. The majority of trials did not undertake active surveillance of pre-defined adverse events. High quality, well reported research in this area is required.
Bi-Layer Wound Dressing System for Combat Casualty Care
2004-09-01
C. Bonacorsi, M.S.G. Raddi, and I.Z. Carlos. 2004. Cytotoxicity of chlorhexidine digluconate to murine macrophages and its effect on hydrogen...chlorexhidine digluconate or 1 % chloramphenicol, as described previously. Each experimental dressing was then covered with a piece of sterile parafilm...chloramphenicol-loaded dressings were 2-log lower for the first 24 h than when applying the chlorhexidine -loaded dressings (Figure 2). However, there was no
Mendes, D A; Veiga, D F; Veiga-Filho, J; Loyola, A B A T; Paiva, L F; Novo, N F; Sabino-Neto, M; Ferreira, L M
2018-06-01
Concepts regarding the best way to treat a surgical wound vary, in literature, ranging from no dressing use to dressing maintenance for 24 to 48 hours or until suture removal. This study aimed to evaluate the influence of the length of dressing maintenance after breast augmentation with implants on cutaneous colonization and surgical site infection. This is a two-arm, parallel group, randomized clinical trial. Eighty patients who were candidates for augmentation mammoplasty with silicone implants were randomly allocated to two groups, in which the dressing was removed on postoperative day 1 (group A, n = 40) or postoperative day 6 (group B, n = 40). Cutaneous colonization was examined by culturing samples collected before and after dressing removal. The criteria defined by the Centers for Disease Control and Prevention were used to assess surgical site infection. No significant difference regarding cutaneous colonization was observed between groups before dressing application. On postoperative day 6, significantly more bacterial growth was observed in group A (p = 0.01). No surgical site infection occurred. We concluded that maintaining the dressing for 6 days led to a lower cutaneous colonization but did not influence surgical site infection rates. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The clinical and cost effectiveness of bee honey dressing in the treatment of diabetic foot ulcers.
Moghazy, A M; Shams, M E; Adly, O A; Abbas, A H; El-Badawy, M A; Elsakka, D M; Hassan, S A; Abdelmohsen, W S; Ali, O S; Mohamed, B A
2010-09-01
Honey is known, since antiquity, as an effective wound dressing. Emergence of resistant strains and the financial burden of modern dressings, have revived honey as cost-effective dressing particularly in developing countries. Its suitability for all stages of wound healing suggests its clinical effectiveness in diabetic foot wound infections. Thirty infected diabetic foot wounds were randomly selected from patients presenting to Surgery Department, Suez Canal University Hospital, Ismailia, Egypt. Honey dressing was applied to wounds for 3 months till healing, grafting or failure of treatment. Changes in grade and stage of wounds, using University of Texas Diabetic Wound Classification, as well as surface area were recorded weekly. Bacterial load was determined before and after honey dressing. Complete healing was significantly achieved in 43.3% of ulcers. Decrease in size and healthy granulation was significantly observed in another 43.3% of patients. Bacterial load of all ulcers was significantly reduced after the first week of honey dressing. Failure of treatment was observed in 6.7% of ulcers. This study proves that commercial clover honey is a clinical and cost-effective dressing for diabetic wound in developing countries. It is omnipresence and concordance with cultural beliefs makes it a typical environmentally based method for treating these conditions. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Milne, Stephen D; Seoudi, Ihab; Al Hamad, Hanadi; Talal, Talal K; Anoop, Anzila A; Allahverdi, Niloofar; Zakaria, Zain; Menzies, Robert; Connolly, Patricia
2016-12-01
Wound moisture is known to be a key parameter to ensure optimum healing conditions in wound care. This study tests the moisture content of wounds in normal practice in order to observe the moisture condition of the wound at the point of dressing change. This study is also the first large-scale observational study that investigates wound moisture status at dressing change. The WoundSense sensor is a commercially available moisture sensor which sits directly on the wound in order to find the moisture status of the wound without disturbing or removing the dressing. The results show that of the 588 dressing changes recorded, 44·9% were made when the moisture reading was in the optimum moisture zone. Of the 30 patients recruited for this study, 11 patients had an optimum moisture reading for at least 50% of the measurements before dressing change. These results suggest that a large number of unnecessary dressing changes are being made. This is a significant finding of the study as it suggests that the protocols currently followed can be modified to allow fewer dressing changes and less disturbance of the healing wound bed. © 2015 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Seeing "the Dress" in the Right Light: Perceived Colors and Inferred Light Sources.
Chetverikov, Andrey; Ivanchei, Ivan
2016-08-01
In the well-known "dress" photograph, people either see the dress as blue with black stripes or as white with golden stripes. We suggest that the perception of colors is guided by the scene interpretation and the inferred positions of light sources. We tested this hypothesis in two online studies using color matching to estimate the colors observers see, while controlling for individual differences in gray point bias and color discrimination. Study 1 demonstrates that the interpretation of the dress corresponds to differences in perceived colors. Moreover, people who perceive the dress as blue-and-black are two times more likely to consider the light source as frontal, than those who see the white-and-gold dress. The inferred light sources, in turn, depend on the circadian changes in ambient light. The interpretation of the scene background as a wall or a mirror is consistent with the perceived colors as well. Study 2 shows that matching provides reliable results on differing devices and replicates the findings on scene interpretation and light sources. Additionally, we show that participants' environmental lighting conditions are an important cue for perceiving the dress colors. The exact mechanisms of how environmental lighting and circadian changes influence the perceived colors of the dress deserve further investigation.
Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel
NASA Astrophysics Data System (ADS)
Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie
2011-05-01
Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.
Tiny patients, tiny dressings: a guide to the neonatal PICC dressing change.
Sharpe, Elizabeth L
2008-06-01
Advances in neonatology now support the survival of the tiniest of infants. The peripherally inserted central catheter (PICC) has now become an integral part of routine practice in neonatal intensive care units around the world. Keen attention to safe maintenance of these devices is essential. A properly applied and maintained PICC dressing is the first line of defense to minimize the risk of complications such as dislodgement, migration, and infection. This article describes a neonatal PICC dressing change and discusses the frequently encountered quandaries surrounding this important procedure, including dressing materials, frequency, site preparation, barrier precautions, and other relevant concerns.
Constructing medical social authority on dress in Victorian Canada.
O'Connor, Eileen
2008-01-01
During the late-Victorian period, campaigns to "reform" middle-class women's dress were grounded in discourses on health, eugenics, declining birth rates, comfort, and aesthetics. In Britain, the United States and Germany, organized "dress reform" movements emerged in the latter half of the 19th century, while in Canada the campaign was led primarily by physicians through public health education. This article explores the discussion on women's dress in public health literature in Canadian circulation between 1860-1900 and interprets findings within a feminist poststructuralist framework that posits the understanding of women's bodies and gender regulation to be central to knowledge construction on women's dress.
Clinical and histologic studies of olfactory outcomes after nasoseptal flap harvesting.
Kim, Sang-Wook; Park, Kyung Bum; Khalmuratova, Roza; Lee, Hong-Kyoung; Jeon, Sea-Yuong; Kim, Dae Woo
2013-07-01
Since the introduction of an endonasal endoscopic approach in transsphenoidal pituitary surgery, reports of perioperative olfactory changes have presented conflicting results. We examined the incidence of olfactory loss in cases of endoscopic transsphenoidal pituitary surgery with skull base repair using the nasoseptal flap (NSF) and the effects of monopolar electrocautery commonly used in designing the NSF. Case-control study. Fifteen patients who underwent endoscopic transsphenoidal pituitary surgery with skull base reconstruction using the NSF were divided into cold knife (n = 8) and electrocautery (n = 7) groups according to the device used in the superior incision of the NSF. Patients were followed regularly to monitor the need for dressing or adhesiolysis around the olfactory cleft. All subjects received olfactory tests before and 6 months after surgery. Septal mucosa specimens obtained during posterior septectomy were incised with different devices, and the degree of mucosal damage was evaluated. One patient in the electrocautery group demonstrated olfactory dysfunction postoperatively, but the other 14 patients showed no decrease in olfaction. In histologic analyses, 55.8% and 76.9% of the mucosal surface showed total epithelial loss when the mucosa was cut with cutting- and coagulation-mode electrocautery, respectively. In contrast, only 20% of the mucosal surface exhibited total epithelial loss when the mucosa was cut with a cold knife (P < .01). Olfactory impairment is not common after use of the NSF. Use of the cold knife in making superior incision may reduce tissue damage with better olfactory outcomes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Bonferoni, Maria Cristina; Sandri, Giuseppina; Rossi, Silvia; Dellera, Eleonora; Invernizzi, Alessandro; Boselli, Cinzia; Cornaglia, Antonia Icaro; Del Fante, Claudia; Perotti, Cesare; Vigani, Barbara; Riva, Federica; Caramella, Carla; Ferrari, Franca
2018-02-09
Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds.
Bonferoni, Maria Cristina; Dellera, Eleonora; Invernizzi, Alessandro; Cornaglia, Antonia Icaro; Perotti, Cesare; Vigani, Barbara; Caramella, Carla; Ferrari, Franca
2018-01-01
Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds. PMID:29425164
Boonbaichaiyapruck, S; Hutayanon, P; Chanthanamatta, P; Dumrongwatana, T; Intarayotha, N; Krisdee, V; Yamvong, S
2001-12-01
Post cardiac catheterization puncture site care is usually done with a tight pressure dressing by an elastic adhesive bandage (Tensoplast) due to the belief that it should prevent bleeding. The practice is uncomfortable to the patients. The authors compared a new way of dressing using light transparent tape (Tegaderm) to the conventional tight pressure one. 126 post coronary angiography patients were randomized to have their groins dressed either with Tensoplast or with Tegaderm. Patients ambulated 8 hours after the procedures. The groin was evaluated for pain, discomfort and bleeding complications. 49 per cent in the Tensoplast vs 26.9 per cent in the Tegaderm group experienced pain (p value of 0.01). 55.5 per cent in the Tensoplast group vs 11.1 per cent in the Tegaderm group reported discomfort. 4.7 per cent in the Tensoplast vs 1.6 per cent in the Tegaderm group developed bleeding or hematoma. Dressing of the puncture site after cardiac catheterization with Tegaderm was more comfortable than the conventional Tensoplast without any difference in bleeding complications.
Effects of honey and sugar dressings on wound healing.
Mphande, A N G; Killowe, C; Phalira, S; Jones, H Wynn; Harrison, W J
2007-07-01
To investigate whether there is a difference between the efficacy of honey and sugar as wound dressings. Patients with open or infected wounds were randomised to receive either honey or sugar dressings. Bacterial colonisation, wound size, wound ASEPSIS score and pain were assessed at the start of treatment and at weekly intervals until full healing occurred. Forty patients were enrolled; 18 received sugar dressings and 22 honey dressings. In the honey group, 55% of patients had positive wound cultures at the start of treatment and 23% at one week, compared with 52% and 39% respectively in the sugar group.The median rate of healing in the first two weeks of treatment was 3.8cm2/week for the honey group and 2.2cm2/week for the sugar group. After three weeks of treatment 86% of patients treated with honey had no pain during dressing changes, compared with 72% treated with sugar. Honey appears to be more effective than sugar in reducing bacterial contamination and promoting wound healing, and slightly less painful than sugar during dressing changes and motion.
Shape memory alloy adaptive control of gas turbine engine compressor blade tip clearance
NASA Astrophysics Data System (ADS)
Schetky, Lawrence M.; Steinetz, Bruce M.
1998-06-01
The ambient air ingested through the inlet of a gas turbine is first compressed by an axial compressor followed by further compression in a centrifugal compressor and then fed into the combustion chamber where ignition and expansion take place to produce the engine thrust. The axial compressor typically has five or more stages which consist of revolving blades and stators and the overall performance of the turbine is strongly affected by the compressor efficiency. When the turbine is turned on, to accommodate the rapid initial increase in the compressor blade length due to centrifugal force, the cold turbine has a built in clearance between the turbine blade tip and the casing. As the turbine reached its operating temperature there is a further increase in the blade length due to thermal expansion and, at the same time, the diameter of the casing increases. The net result is that when these various components have reached their equilibrium temperatures, the initial cold build clearance is reduced, but there remains a residual clearance. The magnitude of this clearance has a direct effect on the compressor efficiency and can be stated as: Δη/Δ CLR equals 0.5 where η is efficiency and CLR is the tip clearance. The concept of adaptive tip clearance control is based on the ability of a shape memory alloy ring to shrink to a predetermined diameter when heated to the temperature of a particular stage, and thus reducing the tip clearance. The ring is fabricated from a CuAlNi shape memory alloy and is mounted in the casing so as to be coaxial with the rotating blades of the particular stage. When cold, the ring dimensions are such as to provide the required cold build clearance, but when at operating temperature the reduced diameter creates a very small tip clearance. The clearance provided by this concept is much smaller than the clearance normally obtained for a turbine of the size being studied.
NASA Astrophysics Data System (ADS)
Abou Eid, Mahear A.
There are many challenges faced with the use of Portland Cement Concrete (PCC) in cold regions, but with the inclusion of new technologies such as steel fibers and recycled tire crumb rubber efficient construction may be possible. Research was conducted on a modified concrete material that included both steel fibers and crumb rubber. The composite material was called Steel Fiber-Reinforced Rubberized Concrete (SFRRC). The objective of this investigation was to provide evidence showing that SFRRC can reduce tire rutting compared to asphaltic pavement. In addition, the research showed that the SFRRC could withstand freeze-thaw cycles and increase service life of roadways. Several tests were performed to determine the characteristics of the material. Freeze-thaw testing was performed to determine compressive strength loss and visual deterioration of the material. Wheel tracker rut testing was performed both with the standard steel wheel and with a modified studded rubber tire to determine plastic deformation and rut resistance. An experimental test slab was cast in place on a public approach to observe the construction procedures, the effects of studded tire wear and the frost actions in cold region conditions. Based on freeze-thaw and wheel tracker test results and observations of the experimental test slab, the SFRRC material shows viability in cold regions for resisting freeze-thaw actions. The freeze-thaw testing resulted in increased compressive strength after 300 freeze-thaw cycles and very low deterioration of material compared to standard PCC. The wheel tracker testing resulted in very low plastic deformation and minor material rutting with use of the studded rubber tire. The test slab showed very minor surface wear, no freeze-thaw cracking and no rutting after one winter of use. It is recommended that further testing of the material be conducted by means of a large-scale trial section. This would provide information with respect to cost analysis and integration of the material into the Department of Transportation construction program.
EVermont Renewable Hydrogen Production and Transportation Fueling System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garabedian, Harold T.
2008-03-30
A great deal of research funding is being devoted to the use of hydrogen for transportation fuel, particularly in the development of fuel cell vehicles. When this research bears fruit in the form of consumer-ready vehicles, will the fueling infrastructure be ready? Will the required fueling systems work in cold climates as well as they do in warm areas? Will we be sure that production of hydrogen as the energy carrier of choice for our transit system is the most energy efficient and environmentally friendly option? Will consumers understand this fuel and how to handle it? Those are questions addressedmore » by the EVermont Wind to Wheels Hydrogen Project: Sustainable Transportation. The hydrogen fueling infrastructure consists of three primary subcomponents: a hydrogen generator (electrolyzer), a compression and storage system, and a dispenser. The generated fuel is then used to provide transportation as a motor fuel. EVermont Inc., started in 1993 by then governor Howard Dean, is a public-private partnership of entities interested in documenting and advancing the performance of advanced technology vehicles that are sustainable and less burdensome on the environment, especially in areas of cold climates, hilly terrain and with rural settlement patterns. EVermont has developed a demonstration wind powered hydrogen fuel producing filling system that uses electrolysis, compression to 5000 psi and a hydrogen burning vehicle that functions reliably in cold climates. And that fuel is then used to meet transportation needs in a hybrid electric vehicle whose internal combustion engine has been converted to operate on hydrogen Sponsored by the DOE EERE Hydrogen, Fuel Cells & Infrastructure Technologies (HFC&IT) Program, the purpose of the project is to test the viability of sustainably produced hydrogen for use as a transportation fuel in a cold climate with hilly terrain and rural settlement patterns. Specifically, the project addresses the challenge of building a renewable transportation energy capable system. The prime energy for this project comes from an agreement with a wind turbine operator.« less
Recuperators for compressed-air energy storage plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakhamkin, M.
1989-12-01
An R D study was conducted to provide an engineering solution to the potential problem of corrosion in the cold-end sections of recuperators operating in compressed-air energy storage (CAES) plants. Two options were developed: (1) a conventional, counterflow recuperator with an easily replaceable cold-end section and (2) a recuperator design which eliminates operation at tube temperatures below the exhaust-gas dew point (advanced design). The advanced design consists of an optimized combination of counterflow and parallel-flow sections. The following data resulting from these studies are included: a history of recuperator operating experience, a summary of lab-testing of various materials for corrosionmore » resistance, detailed design and descriptions of the recuperator designs, additional detail descriptions of alternative air-preheating and turboexpander-exhaust systems, and a comparative economic analysis of the various designs developed. The study concluded that for use with No. 2 fuel oil or lower-grade fuels, the advanced recuperator design with carbon-steel tubes and fins would be more cost-effective and trouble-free than one with an easily replaceable tube section. For CAES plants firing very low-sulfur fuel oil or natural gas, the lower capital-cost, counter-flow design can be considered. It was also concluded that a compressed-air bypass of the recuperator be included in the plant design in the event of recuperator outage, and that the recuperator be designed for operation without cavern air going through it. The advanced recuperator concept is currently being implemented at the 110-MW CAES plant for the Alabama Electric Cooperative, Inc. 6 refs., 24 figs., 20 tabs.« less
The brain's dress code: How The Dress allows to decode the neuronal pathway of an optical illusion.
Schlaffke, Lara; Golisch, Anne; Haag, Lauren M; Lenz, Melanie; Heba, Stefanie; Lissek, Silke; Schmidt-Wilcke, Tobias; Eysel, Ulf T; Tegenthoff, Martin
2015-12-01
Optical illusions have broadened our understanding of the brain's role in visual perception. A modern day optical illusion emerged from a posted photo of a striped dress, which some perceived as white and gold and others as blue and black. Here we show, using functional magnetic resonance imaging (fMRI), that those who perceive The Dress as white/gold have higher activation in response to the image of The Dress in brain regions critically involved in higher cognition (frontal and parietal brain areas). These results are consistent with theories of top-down modulation and present a neural signature associated with the differences in perceiving The Dress as white/gold or blue/black. Furthermore the results support recent psychophysiological data on this phenomenon and provide a fundamental building block to study interindividual differences in visual processing. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Felgueiras, H. P.; Amorim, M. T. P.
2017-10-01
Modern wound dressings combine medical textiles with active compounds that stimulate wound healing while protecting against infection. Electrospun wound dressings have been extensively studied and the electrospinning technique recognized as an efficient approach for the production of nanoscale fibrous mats. The unique diverse function and architecture of antimicrobial peptides (AMPs) has attracted considerable attention as a tool for the design of new anti-infective drugs. Functionalizing electrospun wound dressings with these AMPs is nowadays being researched. In the present work, we explore these new systems by highlighting the most important characteristics of electropsun wound dressings, revealing the importance of AMPs to wound healing, and the methods available to functionalize the electrospun mats with these molecules. The combined therapeutic potential of collagen type I and these AMP functionalized dressings will be highlighted as well; the significance of these new strategies for the future of wound healing will be clarified.
[Split-thickness skin graft donor site: which dressing use?].
Caliot, J; Bodin, F; Chiriac, S; Correia, N; Poli-Mérol, M-L; François-Fiquet, C
2015-04-01
The management of split-thickness skin graft donor sites is targeted towards promoting the healing process, reducing pain. This has been an inconclusive topic. The aim of this study was to list and to discuss the French practices in term of split-thickness skin graft (STSG) donor site dressing. Multicentric national study by questionnaire (Google Drive(®)) for the attention of the plastic and/or pediatric surgeons. The type of dressing used on skin and sclap and the rhythm of dressing changes were analyzed. The study included 26 surgical centers on 40 contacted. The alginate is mainly used (Algostéril(®)) (17/26). It is left in position until healing (13/17). Five other types of dressings have been reported: paraffin gauze (3/26), lipidocolloides (1/26), Mepitel(®) (1/26), Mepilex(®) (1/26), indifferent use of gauze or alginate dressings (4/26). Twenty-two out of 26 centers make no difference in dressing choice between skin and scalp. Medical practices did not differ between adult or pediatric departments. Cost-effectiveness has become an important issue in wound management, requiring judicious use. The lack of consensus regarding split-thickness skin graft donor site dressing and our clinical practices force us to reconsider the best therapeutic option. This study coupled with the analysis of the literature highlights the difficulties of the practitioner in choosing the best dressing. The alginate seems to get the preference of our practices by its ease of use, its absence of change (reduces pain by limiting manipulations) and its moderate cost. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Jung, Jae-A; Yoo, Ki-Hyun; Han, Seung-Kyu; Dhong, Eun-Sang; Kim, Woo-Kyung
2016-12-01
To demonstrate the efficacy of a highly hydrophilic polyurethane foam dressing in the treatment of diabetic ulcers. Diabetic foot ulcers often pose a difficult treatment problem. Polyurethane foam dressings have been used worldwide to accelerate wound healing, but only a few clinical studies demonstrate the effect of foam dressing on the healing of diabetic ulcers. Medical records of 1342 patients with diabetic ulcers who were admitted and treated at the authors' institution were reviewed. A total of 208 patients met the study's inclusion criteria. Of these 208 patients, 137 were treated with a highly hydrophilic polyurethane foam dressing, and 71 were treated with saline gauze (control group). Except for the application of polyurethane foam dressing, the treatment method was identical for patients in both groups. The wound healing outcomes of the 2 groups were compared. Complete wound healing occurred in 87 patients (63.5%) in the polyurethane foam dressing group and in 28 patients (39.4%) in the control group within 12 weeks (P < .05, X test). The mean percentage of wound area reduction in both groups was statistically significant (P < .05, Mann-Whitney U test). The mean time required for complete closure in patients who achieved complete healing within 12 weeks was 6.2 (SD, 3.4) weeks and 7.3 (SD, 2.6) weeks in the polyurethane foam dressing and control groups, respectively (P < .05, Mann-Whitney U test). These results indicate that the highly hydrophilic polyurethane foam dressing may provide an effective treatment strategy for diabetic foot ulcers.
Frontiers in Anisotropic Shock-Wave Modeling
2012-02-01
Nowadays, some models incorporate a user-defined subroutine within the commercial software (e.g., ABAQUS ) to take into account either a homogenous...and temperature on the mass density. The specific internal energy can be decomposed into potentials describing the cold compression, ec (ρ, S); thermal ...Taylor’s series expansion of the Hugoniot pressure P . Assume that the linear approximation between the shock velocity US 24 and particle velocity up
Preliminary Design Guide for Arctic Equipment
1989-05-01
areas that need to be addressed. The components of the various assemblies that Metals , plastics and elastomers make up the subject piece of equipment...polyester elastomer . Allow sufficient length for contraction (- 10- in./in, per IF). Do not allow long, unsup- ported lengths of hose . Lubricants Viscosity...this compressed air cools upon several manufacturers offer teflon hoses with expansion and contact with a cold surface, the braided stainless steel
NASA Astrophysics Data System (ADS)
Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Lazǎr, Veronica; Chifiriuc, Mariana Carmen
2012-12-01
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.
2012-01-01
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues. PMID:23272823
Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Laz R, Veronica; Chifiriuc, Mariana Carmen
2012-12-31
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.
Dense chitosan surgical membranes produced by a coincident compression-dehydration process
Dooley, Thomas P.; Ellis, April L.; Belousova, Maria; Petersen, Don; DeCarlo, Arthur A.
2012-01-01
High density chitosan membranes were produced via a novel manufacturing process for use as implantable resorbable surgical membranes. The innovative method utilizes the following three sequential steps: (1) casting an acidic chitosan solution within a silicon mold, followed by freezing; (2) neutralizing the frozen acidic chitosan solution in alkaline solution to facilitate polymerization; and (3) applying coincident compression-dehydration under a vacuum. Resulting membranes of 0.2 – 0.5 mm thickness have densities as high as 1.6 g/cm3. Inclusion of glycerol prior to the compression-dehydration step provides additional physical and clinical handling benefits. The biomaterials exhibit tensile strength with a maximum load as high as 10.9 N at ~ 2.5 mm width and clinically-relevant resistance to suture pull-out with a maximum load as high as 2.2 N. These physical properties were superior to those of a commercial reconstituted collagen membrane. The dense chitosan membranes have excellent clinical handling characteristics, such as pliability and “memory” when wet. They are semi-permeable to small molecules, biodegradable in vitro in lysozyme solution, and the rates of degradation are inversely correlated to the degree of deacetylation. Furthermore, the dense chitosan membranes are biocompatible and resorbable in vivo as demonstrated in a rat oral wound healing model. The unique combination of physical, in vitro, in vivo, and clinical handling properties demonstrate the high utility of dense chitosan membranes produced by this new method. The materials may be useful as surgical barrier membranes, scaffolds for tissue engineering, wound dressings, and as delivery devices for active ingredients. PMID:23565872
Exploratory Development of an Ultrafast-Curing Wound Dressing
1991-05-31
mils thick: Formulation 2 and 5 .. 36 17. Elution Rates for the 30% Chlorhexidine Gluconate ADD’s at t=0 and Stored at the Temperature Extremes (400C...determined from the in vivo trials conducted earlier (9). The 6 mil thick dressing (Formulation 2) demonstrated effectiveness when tested on guinea pigs...This dressing released approximately 3000 micrograms/sq. cm. in 72 hours or about 64% of the 12 mil dressing tested for shelf stability (Figure 16
Woo, Kevin Y
2015-07-01
The purpose of this study was to examine the mediating effect of anxiety in the relationship between anticipation and pain in people with chronic wounds. Pain is common in people with chronic wounds. Anticipation or negative expectation of discomfort has been shown to have an augmenting effect on pain; also known as nocebo hyperalgesia. This was a cross-sectional study with repeated measures. Prior to dressing change, anticipatory pain level was evaluated by a 11-point numerical rating scale and anxiety by the Six-items State-Trait Anxiety Inventory (STAI-6). During wound dressing changes, pain was measured before dressing removal, at dressing removal, at cleansing and dressing application using the numerical scale. Analysis was completed based on the data from a convenience sample of 96 patients. Participants reported more pain at cleansing and dressing removal than baseline. High levels of anticipation, anxiety and pain at dressing change for wounds were related to heavy exudate and wound that were covered with necrotic tissue. Finally, the relationship between anticipation and pain perception was mediated by anxiety. Anticipation of pain triggers anxiety that can lead to increased pain. There is a need to incorporate evaluation of anxiety and personal expectations as part of comprehensive pain assessment. Clinicians should be aware of the impact of emotions and anticipation on overall pain experience. © 2015 John Wiley & Sons Ltd.
Ng, Shiow-Fern; Lew, Pit-Chin; Sin, Yong-Boey
2014-11-01
Topical emollients are known to provide symptomatic relief for atopic dermatitis. In hospitals, wet-wrap therapy has been shown to benefit children with moderate-to-severe atopic dermatitis (AD), but the application of wet-wraps is tedious and time-consuming. Topical emollients have low residence time and often dry out easily. The aim of this work was to develop a hydrogel-gauze dressing that is not only easy to apply but also rehydrates and traps moisture to provide longer relief for AD patients. In this study, a prototype hydrogel-gauze dressing was developed with varying ratios of sodium carboxymethylcellulose (NaCMC) and propylene glycol. The hydrogel-gauze dressings were assessed based on the moisture vapor transmission rate, moisture absorption, mechanical properties and storage stability over three months. Then, the efficacy of the hydrogel-gauze dressing was compared to topical emollients using transgenic NC/Nga mice with AD-like lesions. The NaCMC hydrogel-gauze dressings significantly lowered transepidermal water loss, and the animals displayed a faster recovery, which indicates that hydrogel-gauze dressings can trap moisture more effectively and accelerate AD healing. Hence, we propose that hydrogel-gauze dressings can potentially become an alternative to wet-wrap therapy due to the ease of application and the higher efficacy compared to topical products.
Van Hoesel, Willem; Tiefenbacher, Alexandra; König, Nina; Dorn, Verena M; Hagenguth, Julia F; Prah, Urša; Widhalm, Theresia; Wiklicky, Viktoria; Koller, Robert; Bonkowski, Michael; Lagerlöf, Jan; Ratzenböck, Andreas; Zaller, Johann G
2017-01-01
Seed dressing, i.e., the treatment of crop seeds with insecticides and/or fungicides, aiming to protect seeds from pests and diseases, is widely used in conventional agriculture. During the growing season, those crop fields often receive additional broadband herbicide applications. However, despite this broad utilization, very little is known on potential side effects or interactions between these different pesticide classes on soil organisms. In a greenhouse pot experiment, we studied single and interactive effects of seed dressing of winter wheat ( Triticum aestivum L. var. Capo ) with neonicotinoid insecticides and/or strobilurin and triazolinthione fungicides and an additional one-time application of a glyphosate-based herbicide on the activity of earthworms, soil microorganisms, litter decomposition, and crop growth. To further address food-web interactions, earthworms were introduced to half of the experimental units as an additional experimental factor. Seed dressings significantly reduced the surface activity of earthworms with no difference whether insecticides or fungicides were used. Moreover, seed dressing effects on earthworm activity were intensified by herbicides (significant herbicide × seed dressing interaction). Neither seed dressings nor herbicide application affected litter decomposition, soil basal respiration, microbial biomass, or specific respiration. Seed dressing did also not affect wheat growth. We conclude that interactive effects on soil biota and processes of different pesticide classes should receive more attention in ecotoxicological research.
Gerçeker, Gülçin Özalp; Yardımcı, Figen; Aydınok, Yeşim
2017-06-01
To compare the effects of the care bundles including chlorhexidine dressing and advanced dressings on the catheter-related bloodstream infection (CRBSI) rates in pediatric hematology-oncology patients with central venous catheters (CVCs). Twenty-seven PHO patients were recruited to participate in a prospective, randomized study in Turkey. The researcher used care bundles with chlorhexidine dressing in the experimental group (n = 14), and care bundles with advanced dressings in the control group (n = 13). According to the study results, 28.6% of the patients in the experimental group had CRBSI, while this rate was 38.5% in the control group patients. The CRBSI rate in the experimental group was 3.9, and the control group had 4.4 per 1000 inpatient catheter days. There was no exit-site infection in the experimental group. However, the control group had 1.7 per 1000 inpatient catheter days. Even though there was no difference between the two groups in which the researcher implemented care bundles with chlorhexidine dressing and advanced dressings in terms of CRBSI development, there was reduction in the CRBSI rates thanks to the care bundle approach. It is possible to control the CRBSI rates using care bundles in pediatric hematology-oncology patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz
2015-08-12
The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used.
Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz
2015-01-01
Background The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Material/Methods Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. Results All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Conclusions Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used. PMID:26264209
Suzuki, Makoto; Yamada, Sumio; Omori, Mikayo; Hatakeyama, Mayumi; Sugimura, Yuko; Matsushita, Kazuhiko; Tagawa, Yoshikatsu
2008-09-01
A patient with poststroke hemiparesis learns to use the nonparetic arm to compensate for the weakness of the paretic arm to achieve independence in dressing. This is the learning process of new component actions on dressing. The purpose of this study was to develop the Upper-Body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the component actions of upper-body dressing, and to provide preliminary data on internal consistency of the UBDS, as well as its reproducibility, validity, and sensitivity to clinical change. Correlational study of concurrent validity and reliability in which 63 consecutive stroke patients were enrolled in the study and were assessed repeatedly by the UBDS and the dressing item of Functional Independent Measure (FIM). Fifty-one patients completed the 3-wk study. The Cronbach's coefficient alpha of UBDS was 0.88. The principal component analysis extracted two components, which explained 62.3% of total variance. All items of the scale had high loading on the first component (0.65-0.83). Actions on the paralytic side were the positive loadings and actions on the healthy side were the negative loadings on the second component. Intraclass correlation coefficient was 0.87. The level of correlation between UBDS score and FIM dressing item scores was -0.72. Logistic regression analysis showed that only the score of UBDS on the first day of evaluation was a significant independent predictor of dressing ability (odds ratio, 0.82; 95% confidence interval, 0.71-0.95). The UBDS scores for paralytic hand passed into the sleeve, sleeve pulled up beyond the elbow joint, and sleeve pulled up beyond the shoulder joint were worse than the score for the other components of the task. These component actions had positive loading on the second component, which was identified by the principal component analysis. The UBDS has good internal consistency, reproducibility, validity, and sensitivity to clinical changes of patients with poststroke hemiparesis. This detailed UBDS assessment enables us to document the most difficult stages in dressing and to assess motor and process skills for independence of dressing.
Eves, Neil D; Petersen, Stewart R; Jones, Richard L
2003-10-01
The self-contained breathing apparatus (SCBA) used by firefighters, and other working in dangerous environments, adds an external resistance to expiration, which increases expiratory work during heavy exercise. Compressed air is typically used with the SCBA and we hypothesized that changing the inspired oxygen concentration and/or gas density with helium would reduce the external expiratory resistance. On separate days, 15 men completed four 30-min bouts of treadmill exercise dressed in protective clothing and breathing the test gases through the SCBA. Four different gas mixtures were assigned in random order: [compressed air (NOX: 21% O2, 79% N2), hyperoxia (HOX: 40% O2, 60% N2), normoxic-helium (HE-OX: 21% O2, 79% He), and helium-hyperoxia (HE-HOX: 40% O2, 60% He)]. Compared with NOX, the two helium mixtures (but not HOX), decreased the external breathing resistance and all three gas mixtures decreased the peak expired mask pressure and the ventilatory mass moved. Both hyperoxic mixtures decreased blood lactate and the rating of perceived exertion was decreased at 30 min with HE-HOX. These results demonstrate that the helium-based gas mixtures, and to a lesser extent HOX, reduce the expiratory work associated with the SCBA during strenuous exercise.
8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...
8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (LEFT) AND DRESSED, DRY-LAID RETAINING WALL (RIGHT). FACING WEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA
10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...
10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (RIGHT) AND DRESSED, DRY-LAID RETAINING WALL (LEFT). FACING NORTHWEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA
Junka, Adam F; Żywicka, Anna; Szymczyk, Patrycja; Dziadas, Mariusz; Bartoszewicz, Marzena; Fijałkowski, Karol
2017-12-01
In the present article, we propose a simple Antibiofilm Dressing's Activity Measurement (A.D.A.M.) test that allows to check in vitro a dressing's suitability against biofilm-related wound infections. To perform the test, three agar discs are covered with biofilm formed by the tested pathogen after which they are assembled one over another in the form of an agar plug and placed in the well of a 24-well plate. The top disc is covered with the analyzed dressing and the entire set is incubated for 24h. During this time, the investigated antimicrobial substance is released from the dressing and penetrates to subsequent biofilm-covered agar discs. Biofilm reduction is measured using 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) spectrometric assay and the results are compared to untreated control samples (agar plug covered with biofilm and without the dressing/or with a passive dressing placed on the top disc). Furthermore, in order to standardize the differences in penetrability of the drugs released from active dressings the results can be expressed as a dimensionless value referred to as the Penetrability Index. In summary, A.D.A.M. test is simple, cheap, can be performed practically in every clinical laboratory and takes no more time than routine microbiological diagnostics. Apart from measuring the released drug's activity, the A.D.A.M. test allows to assess drug penetrability (across three agar discs), reflecting real wound conditions, where microbes are frequently hidden under the necrotic tissue or cloth. In conclusion, the A.D.A.M. test produces a high volume of data that, when analyzed, can provide a researcher with a valuable hint concerning the applicability of active dressings against specific biofilm pathogens in a particular setting. Copyright © 2017 Elsevier B.V. All rights reserved.
Lo, Shu-Fen; Chang, Chee-Jen; Hu, Wen-Yu; Hayter, Mark; Chang, Yu-Ting
2009-03-01
The purpose of this study was to examine the efficacy of silver-releasing dressings in the management of non-healing chronic wounds. Non-healing chronic wounds often have a negative physical impact on patients and place a financial burden on healthcare systems. Silver dressings are wound products designed to control infection and provide a wound environment conducive to healing. However, validation of the clinical efficacy of these dressings is lacking. Systematic review and meta-analysis. A systematic search of the major electronic databases PubMed, CINAHL, Cochrane, MEDLINE, British Nursing Index, EBSCO, OCLC and Proquest between 1950-June 2007 was conducted. Hand searches of selected periodicals, textbooks and checking reference lists and contacting experts was also performed. Eight studies were selected from a potentially relevant 1957 references screened. Analysis incorporated data from 1399 participants in the eight randomised control trials. We found that silver dressings significantly improved wound healing (CI(95): 0.16-0.39, p < 0.001), reduced odour (CI(95): 0.24-0.52, p < 0.001) and pain-related symptoms (CI(95): 0.18-0.47, p < 0.001), decreased wound exudates (CI(95): 0.17-0.44, p < 0.001) and had a prolonged dressing wear time (CI(95): 0.19-0.48, p = 0.028) when compared with alternative wound management approaches. An analysis of sensitivity in these studies by subgroup analysis generally supported these associations. Furthermore, studies indicated an improvement in quality of life (CI(95): 0.04-0.33, p = 0.013) using silver dressings in wound management with no associated severe adverse events. This meta-analysis confirms the effectiveness of silver dressings in wound healing and improving patients' quality of life. However, it also highlights the need for additional well-designed randomised controlled trials to evaluate the effectiveness of silver-related dressings further. The results of this study provide objective data on the effectiveness of silver-related dressing when applied to non-healing chronic wounds.
NASA Astrophysics Data System (ADS)
Chen, Mingjun; Li, Ziang; Yu, Bo; Peng, Hui; Fang, Zhen
2013-09-01
In the grinding of high quality fused silica parts with complex surface or structure using ball-headed metal bonded diamond wheel with small diameter, the existing dressing methods are not suitable to dress the ball-headed diamond wheel precisely due to that they are either on-line in process dressing which may causes collision problem or without consideration for the effects of the tool setting error and electrode wear. An on-machine precision preparation and dressing method is proposed for ball-headed diamond wheel based on electrical discharge machining. By using this method the cylindrical diamond wheel with small diameter is manufactured to hemispherical-headed form. The obtained ball-headed diamond wheel is dressed after several grinding passes to recover geometrical accuracy and sharpness which is lost due to the wheel wear. A tool setting method based on high precision optical system is presented to reduce the wheel center setting error and dimension error. The effect of electrode tool wear is investigated by electrical dressing experiments, and the electrode tool wear compensation model is established based on the experimental results which show that the value of wear ratio coefficient K' tends to be constant with the increasing of the feed length of electrode and the mean value of K' is 0.156. Grinding experiments of fused silica are carried out on a test bench to evaluate the performance of the preparation and dressing method. The experimental results show that the surface roughness of the finished workpiece is 0.03 μm. The effect of the grinding parameter and dressing frequency on the surface roughness is investigated based on the measurement results of the surface roughness. This research provides an on-machine preparation and dressing method for ball-headed metal bonded diamond wheel used in the grinding of fused silica, which provides a solution to the tool setting method and the effect of electrode tool wear.
Zhou, Xin; Wang, He; Zhang, Jimin; Li, Xuemei; Wu, Yifan; Wei, Yongzhen; Ji, Shenglu; Kong, Deling; Zhao, Qiang
2017-05-01
Wound healing dressings are increasingly needed clinically due to the large number of skin damage annually. Nitric oxide (NO) plays a key role in promoting wound healing, thus biomaterials with NO-releasing property receive increasing attention as ideal wound dressing. In present study, we prepared a novel functional wound dressing by combining electrospun poly(ε-caprolactone) (PCL) nonwoven mat with chitosan-based NO-releasing biomaterials (CS-NO). As-prepared PCL/CS-NO dressing released NO sustainably under the physiological conditions, which was controlled by the catalysis of β-galactosidase. In vivo wound healing characteristics were further evaluated on full-thickness cutaneous wounds in mice. Results showed that PCL/CS-NO wound dressings remarkably accelerated wound healing process through enhancing re-epithelialization and granulation formation and effectively improved the organization of regenerated tissues including epidermal-dermal junction, which could be ascribed to the pro-angiogenesis, immunomodulation, and enhanced collagen synthesis provided by the sustained release of NO. Therefore, PCL/CS-NO may be a promising candidate for wound dressings, especially for the chronic wound caused by the ischemia. Serious skin damage caused by trauma, surgery, burn or chronic disease has become one of the most serious clinical problems. Therefore, there is an increasing demand for ideal wound dressing that can improve wound healing. Due to the vital role of nitric oxide (NO), we developed a novel functional wound dressing by combining electrospun polycaprolactone (PCL) mat with NO-releasing biomaterial (CS-NO). The sustained release of NO from PCL/CS-NO demonstrated positive effects on wound healing, including pro-angiogenesis, immunomodulation, and enhanced collagen synthesis. Hence, wound healing process was remarkably accelerated and the organization of regenerated tissues was effectively improved as well. Taken together, PCL/CS-NO dressing may be a promising candidate for wound treatment, especially for the chronic wound caused by the ischemia. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Crystallographic and magnetic structure of HAVAR under high-pressure using diamond anvil cell (DAC)
NASA Astrophysics Data System (ADS)
Halevy, Itzhak; Haroush, Shlomo; Eisen, Yosef; Silberman, Ido; Moreno, Dany; Hen, Amir; Winterrose, Mike L.; Ghose, Sanjit; Chen, Zhiqiang
2010-04-01
Annealed (H1) and cold-rolled (H2) HAVAR has been studied using high-pressure synchrotron X-ray diffraction. A structural phase transformation was discovered at ˜13 GPa at ambient temperature, transforming from m - 3 m (S.G. 225) to P 63/m m c (S.G. 194) symmetry. The transition was not reversible on pressure release. The low-pressure cubic phase was found to be more compressible than the high-pressure hexagonal phase. Conventional Mössbauer and NFS shows that the HAVAR is not magnetic at room temperature and no splitting is observed. The SQUID indicates a huge difference in the temperature dependence of the magnetic susceptibility between the cold Rolled HAVAR compared to the annealed HAVAR.
An improved thermodynamic perturbation theory for Mercedes-Benz water
NASA Astrophysics Data System (ADS)
Urbic, T.; Vlachy, V.; Kalyuzhnyi, Yu. V.; Dill, K. A.
2007-11-01
We previously applied Wertheim's thermodynamic perturbation theory for associative fluids to the simple Mercedes-Benz model of water. We found that the theory reproduced well the physical properties of hot water, but was less successful in capturing the more structured hydrogen bonding that occurs in cold water. Here, we propose an improved version of the thermodynamic perturbation theory in which the effective density of the reference system is calculated self-consistently. The new theory is a significant improvement, giving good agreement with Monte Carlo simulations of the model, and predicting key anomalies of cold water, such as minima in the molar volume and large heat capacity, in addition to giving good agreement with the isothermal compressibility and thermal expansion coefficient.
NASA Technical Reports Server (NTRS)
Wilder, F. D.; Ergun, R. E.; Schwartz, S. J.; Newman, D. L.; Eriksson, S.; Stawarz, J. E.; Goldman, M. V.; Goodrich, K. A.; Gershman, D. J.; Malaspina, D.;
2016-01-01
On 8 September 2015, the four Magnetospheric Multiscale spacecraft encountered a Kelvin-Helmholtz unstable magnetopause near the dusk flank. The spacecraft observed periodic compressed current sheets, between which the plasma was turbulent. We present observations of large-amplitude (up to 100 mVm) oscillations in the electric field. Because these oscillations are purely parallel to the background magnetic field, electrostatic, and below the ion plasma frequency, they are likely to be ion acoustic-like waves. These waves are observed in a turbulent plasma where multiple particle populations are intermittently mixed, including cold electrons with energies less than 10 eV. Stability analysis suggests a cold electron component is necessary for wave growth.
An improved thermodynamic perturbation theory for Mercedes-Benz water.
Urbic, T; Vlachy, V; Kalyuzhnyi, Yu V; Dill, K A
2007-11-07
We previously applied Wertheim's thermodynamic perturbation theory for associative fluids to the simple Mercedes-Benz model of water. We found that the theory reproduced well the physical properties of hot water, but was less successful in capturing the more structured hydrogen bonding that occurs in cold water. Here, we propose an improved version of the thermodynamic perturbation theory in which the effective density of the reference system is calculated self-consistently. The new theory is a significant improvement, giving good agreement with Monte Carlo simulations of the model, and predicting key anomalies of cold water, such as minima in the molar volume and large heat capacity, in addition to giving good agreement with the isothermal compressibility and thermal expansion coefficient.
Biophysical effects of repetitive removal of adhesive dressings on peri-ulcer skin.
Zillmer, R; Agren, M S; Gottrup, F; Karlsmark, T
2006-05-01
To study the effect of repeated removal of four different adhesive dressings on peri-ulcer skin using quantitative non-invasive techniques. Forty-five patients with open (n = 29) or healed (n = 16) venous leg ulcers were included. Peri-ulcer skin was treated for 14 days with patches of two different hydrocolloid-based adhesive dressings, one polyurethane adhesive and one soft silicone adhesive dressing. Normal skin of the patients' ventral forearm was also treated identically. Adhesive patches of the dressings were replaced every second day. The skin barrier function was assessed by measuring transepidermal water loss and stratum corneum hydration by measuring electrical conductance. Thirty-nine patients completed the study. The hydrocolloid adhesives increased transepidermal water loss and conductance while the polyurethane and soft silicone adhesives did not influence these parameters significantly compared with adjacent non-treated peri-ulcer skin. For normal forearm skin, similar relative effects among the four adhesives were found. Repetitive treatment with hydrocolloid-based adhesive dressings induced major functional alterations of the stratum corneum. In contrast, a polyurethane adhesive and a soft silicone adhesive dressing did not alter transepidermal water loss or conductance of peri-ulcer skin.
Peroxide-based oxygen generating topical wound dressing for enhancing healing of dermal wounds.
Chandra, Prafulla K; Ross, Christina L; Smith, Leona C; Jeong, Seon S; Kim, Jaehyun; Yoo, James J; Harrison, Benjamin S
2015-01-01
Oxygen generating biomaterials represent a new trend in regenerative medicine that aims to generate and supply oxygen at the site of requirement, to support tissue healing and regeneration. To enhance the healing of dermal wounds, we have developed a highly portable, in situ oxygen generating wound dressings that uses sodium percarbonate (SPO) and calcium peroxide (CPO) as chemical oxygen sources. The dressing continuously generated oxygen for more than 3 days, after which it was replaced. In the in vivo testing on porcine full-thickness porcine wound model, the SPO/CPO dressing showed enhanced wound healing during the 8 week study period. Quantitative measurements of wound healing related parameters, such as wound closure, reepithelialization, epidermal thickness and collagen content of dermis showed that supplying oxygen topically using the SPO/CPO dressing significantly accelerated the wound healing. An increase in neovascularization, as determined using Von Willebrand factor (vWF) and CD31 staining, was also observed in the presence of SPO/CPO dressing. This novel design for a wound dressing that contains oxygen generating biomaterials (SPO/CPO) for supplying topical oxygen, may find utility in treating various types of acute to chronic wounds. © 2015 by the Wound Healing Society.
Misgav, Mudi; Kenet, Gili; Martinowitz, Uriel
2014-03-01
Bleeding episodes in patients with congenital or acquired bleeding disorders are usually managed with factor concentrates or blood products. However, external and accessible bleeds may effectively be managed with topical hemostasis. After the application of the Hemcon, a Food and Drug Administration-approved chitosan-based hemostatic dressing was used as the "last resort" to successfully control external bleeds in 2 patients with severe bleeding disorders. We describe a single-center experience with this dressing, including its use in pediatric patients as the first mode of therapy. A total of 5 patients (median age 2 y) with severe bleeding disorders were treated with topical chitosan-based dressing for a total of 6 bleeding episodes. The dressing was used either after the failure of extensive systemic therapy or as the first choice of treatment. In 4 of the 6 episodes, bleeding ceased immediately alleviating the need for systemic therapy. There was no rebleeding after the removal of the dressing and no adverse events or local skin reactions were recorded. Hemostatic dressings, such as the chitosan, should be encouraged for the treatment of external/accessible bleeds, especially among the pediatric patients with bleeding tendency.
Plasma treatments of dressings for wound healing: a review.
Eswaramoorthy, Nithya; McKenzie, David R
2017-12-01
This review covers the use of plasma technology relevant to the preparation of dressings for wound healing. The current state of knowledge of plasma treatments that have potential to provide enhanced functional surfaces for rapid and effective healing is summarized. Dressings that are specialized to the needs of individual cases of chronic wounds such as diabetic ulcers are a special focus. A summary of the biology of wound healing and a discussion of the various types of plasmas that are suitable for the customizing of wound dressings are given. Plasma treatment allows the surface energy and air permeability of the dressing to be controlled, to ensure optimum interaction with the wound. Plasmas also provide control over the surface chemistry and in cases where the plasma creates energetic ion bombardment, activation with long-lived radicals that can bind therapeutic molecules covalently to the surface of the dressing. Therapeutic innovations enabled by plasma treatment include the attachment of microRNA or antimicrobial peptides. Bioactive molecules that promote subsequent cell adhesion and proliferation can also be bound, leading to the recruitment of cells to the dressing that may be stem cells or patient-derived cells. The presence of a communicating cell population expressing factors promotes healing.
Topical Application of Honey on Surgical Wounds: A Randomized Clinical Trial.
Goharshenasan, Peiman; Amini, Shahideh; Atria, Ali; Abtahi, Hamidreza; Khorasani, Ghasemali
2016-01-01
The antimicrobial and anti-inflammatory activity of honey and its ability to accelerate wound healing make it an attractive option in surgical wound care. We performed a randomized clinical trial to compare the efficacy of honey dressing with conventional dressing regarding the aesthetic outcome. Bilateral symmetric incisions in randomly selected plastic surgical patients were randomly covered postoperatively with conventional dressing and honey dressing for five days. The aesthetic outcome of the two sides was rated on a Visual Analog Scale by the surgeon and the patient and compared at month three and six after surgery. Seventy two symmetrical incisions in 52 patients were evaluated during the study. The mean width of the scar after the third and the sixth month was 3.64 +/- 0.83 mm and 3.49 +/- 0.87 mm on the side that received honey dressing and 5.43 +/- 0.05 mm and 5.30+/- 1.35 mm in the control group. Wilcoxon signed-rank test showed significant difference between honey and conventional dressing outcomes at third and sixth month (p < 0.001). The healing process of the surgical wound and its final aesthetic result could be improved by using honey dressing. © 2016 S. Karger GmbH, Freiburg.
Aduba, Donald C.; Yang, Hu
2017-01-01
Wound dressings are critical for wound care because they provide a physical barrier between the injury site and outside environment, preventing further damage or infection. Wound dressings also manage and even encourage the wound healing process for proper recovery. Polysaccharide biopolymers are slowly becoming popular as modern wound dressings materials because they are naturally derived, highly abundant, inexpensive, absorbent, non-toxic and non-immunogenic. Polysaccharide biopolymers have also been processed into biomimetic platforms that offer a bioactive component in wound dressings that aid the healing process. This review primarily focuses on the fabrication and biocompatibility assessment of polysaccharide materials. Specifically, fabrication platforms such as electrospun fibers and hydrogels, their fabrication considerations and popular polysaccharides such as chitosan, alginate, and hyaluronic acid among emerging options such as arabinoxylan are discussed. A survey of biocompatibility and bioactive molecule release studies, leveraging polysaccharide’s naturally derived properties, is highlighted in the text, while challenges and future directions for wound dressing development using emerging fabrication techniques such as 3D bioprinting are outlined in the conclusion. This paper aims to encourage further investigation and open up new, disruptive avenues for polysaccharides in wound dressing material development. PMID:28952482
Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knudsen, Peter N.; Ganni, Venkatarao; Dixon, Kelly D.
The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6more » kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.« less
NASA Technical Reports Server (NTRS)
Hartfield, Roy J., Jr.; Hollo, Steven D.; Mcdaniel, James C.
1992-01-01
A unified laser-induced fluorescence technique for conducting planar measurements of temperature, pressure and velocity in nonreacting, highly compressible flows has been developed, validated and demonstrated. Planar fluorescence from iodine, seeded into air, was induced by an argon-ion laser and collected using a liquid-nitrogen cooled CCD camera. In the measurement technique, temperature is determined from the fluorescence induced with the laser operated broad band. Pressure and velocity are determined from the shape and position of the fluorescence excitation spectrum which is measured with the laser operated narrow band. The measurement approach described herein provides a means of obtaining accurate, spatially-complete maps of the primary flow field parameters in a wide variety of cold supersonic and transonic flows.
NASA Astrophysics Data System (ADS)
Zhang, L.; Dang, H. Z.; Tan, J.; Bao, D.; Zhao, Y. B.; Qian, G. Z.
2015-12-01
Theoretical and experimental investigations on the dynamic and thermodynamic characteristics of a linear compressor incorporating the thermodynamic characteristics of the inertance tube pulse tube cold finger have been made. Both the compressor and cold finger are assumed as a one-dimensional thermodynamic model. The governing equations of the thermodynamic characteristics of the working gas are summarized, and the effects of the cooling performance on the working gas in the compression space are discussed. Based on the analysis of the working gas, the governing equations of the dynamic and thermodynamic characteristics of the compressor are deduced, and then the principles of achieving the optimal performance of the compressor are discussed in detail. Systematic experimental investigations are conducted on a developed moving-coil linear compressor which drives a pulse tube cold finger, which indicate the general agreement with the simulated results, and thus verify the rationality of the theoretical model and analyses.
Overview of deaths associated with natural events, United States, 1979-2004.
Thacker, Maria T F; Lee, Robin; Sabogal, Raquel I; Henderson, Alden
2008-06-01
Analysis of the National Center for Health Statistics' Compressed Mortality File showed that between 1979 and 2004, natural events caused 21,491 deaths in the United States. During this 26-year period, there were 10,827 cold-related deaths and 5,279 heat-related deaths. Extreme cold or heat accounted for 75 per cent of the total number of deaths attributed to natural events--more than all of deaths resulting from lightning, storms and foods, and earth movements, such as earthquakes and landslides. Cold-related death rates were highest in the states of Alaska, Montana, New Mexico, and South Dakota, while heat-related deaths were highest in the states of Arizona, Missouri, and Arkansas. These deaths occurred more often among the elderly and black men. Other deaths were attributed to lightning (1,906), storms and foods (2,741), and earth movements (738). Most deaths associated with natural events are preventable and society can take action to decrease the morbidity and mortality connected with them.
Aramwit, Pornanong; Yamdech, Rungnapha; Ampawong, Sumate
2016-05-01
One approach in wound dressing development is to incorporate active molecules or drugs in the dressing. In order to reduce the frequency of dressing changes as well as to prolong wound healing efficacy, wound dressings that can sustain the release of the active molecules should be developed. In our previous work, we developed chitosan/sericin (CH/SS) microspheres that released sericin in a controlled rate. However, the difficulty of applying the microspheres that easily diffuse and quickly degrade onto the wound was its limitations. In this study, we aimed to develop wound dressing materials which are easier to apply and to provide extended release of sericin. Different amounts of CH/SS microspheres were embedded into various compositions of polyvinyl alcohol/gelatin (PVA/G) scaffolds and fabricated using freeze-drying and glutaraldehyde crosslinking techniques. The obtained CH/SS microspheres-embedded scaffolds with appropriate design and formulation were introduced as a wound dressing material. Sericin was released from the microspheres and the scaffolds in a sustained manner. Furthermore, an optimized formation of the microspheres-embedded scaffolds (2PVA2G+2CHSS) was shown to possess an effective antimicrobial activity against both gram-positive and gram-negative bacteria. These microspheres-embedded scaffolds were not toxic to L929 mouse fibroblast cells, and they did not irritate the tissue when applied to the wound. Finally, probably by the sustained release of sericin, these microspheres-embedded scaffolds could promote wound healing as well as or slightly better than a clinically used wound dressing (Allevyn®) in a mouse model. The antimicrobial CH/SS microspheres-embedded PVA/G scaffolds with sustained release of sericin would appear to be a promising candidate for wound dressing application.
Assadian, Ojan; Arnoldo, Brett; Purdue, Gary; Burris, Agnes; Skrinjar, Edda; Duschek, Nikolaus; Leaper, David J
2015-06-01
This prospective, randomised study compares a new transforming methacrylate dressing (TMD) with a silver-containing carboxymethylcellulose dressing (CMC-Ag) after application to split-thickness skin graft (STSG) donor sites. This was an unblinded, non-inferiority, between-patient, comparison study that involved patients admitted to a single-centre burn unit who required two skin graft donor sites. Each patient's donor sites were covered immediately after surgery: one donor site with TMD and the other with CMC-Ag. The donor sites were evaluated until healing or until 24 days post-application, whichever came first. Study endpoints were time to healing, daily pain scores, number of dressing changes, patient comfort and physicians' and patients' willingness to use the dressings in the future. Nineteen patients had both the dressings applied. No statistically significant difference was noted in time to healing between the two dressings (14·2 days using TMD compared with 13·2 days using CMC-Ag). When pain scores were compared, TMD resulted in statistically significantly less pain at three different time periods (2-5 days, 6-10 days and 11-15 days; P < 0·001 at all time periods). Patients also reported greater comfort with TMD (P < 0·001). Users rated TMD as being less easy to use because of the time and technique required for application. Reductions in pain and increased patient comfort with the use of the TMD dressing, compared with CMC-Ag, were seen as clinical benefits as these are the major issues in donor site management. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Wang, Li; Li, Lin-Feng
2017-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome is a severe drug-induced hypersensitivity reaction characterized by skin rash, fever, blood abnormalities, and multiple organ involvement. The diagnosis of DRESS syndrome is often delayed because of its variable presentation. Prompt withdrawal of the culprit drug is the definitive treatment. DRESS syndrome induced by antituberculosis drugs has rarely been reported. A 50-year-old man admitted to our hospital with recurrent episodes of progressive rash, fever, eosinophilia, lymphadenopathy, hepatic, and pulmonary involvement were experienced after repeat trials of the same antituberculosis drugs. We diagnosed it as DRESS caused by antituberculosis drugs. The case responded well to treatment with systemic corticosteroids and intravenous immunoglobulins. However, repeated bouts of infection with methicillin-resistant Staphylococcus aureus occurred during treatment (clavicular osteomyelitis and knee septic arthritis). He was cured after treatment with linezolid. The patient was discharged on day 112. At 8-month follow-up, there was no relapse of drug eruption and joint swelling. Early diagnosis and prompt withdrawal of all suspected drugs is a key tenet of the treatment of DRESS. Our case report highlights the risks inherent in delayed diagnosis of DRESS and the challenges in the clinical management of this condition. Pulmonary manifestations with radiological changes on chest X-ray and CT can be seen in DRESS. These changes need to be differentiated from those caused by pulmonary infections. Clavicular osteomyelitis infected with MRSA may be caused by iatrogenic injury during subclavian vein catheterization. This type of MRSA infections should be treated for 4 to 6 weeks. Blood eosinophilia could be a useful marker of disease progression and treatment response in patients with DRESS. However, more experience and clinical evidence is needed to confirm this.
Nakagami, Gojiro; Sanada, Hiromi; Konya, Chizuko; Kitagawa, Atsuko; Tadaka, Etsuko; Matsuyama, Yutaka
2007-09-01
This paper is a report of an evaluation of the effectiveness of a newly developed dressing for preventing persistent erythema and pressure ulcer development and improving the water-holding capacity without increasing the skin pH in bedridden older patients. Shear forces and skin dryness play important roles in persistent erythema and pressure ulcer development. To eliminate these risks, we developed a dressing to reduce shear forces and improve the water-holding capacity. However, the effects of this dressing in clinical settings remain unknown. An experimental bilateral comparison study was conducted at a hospital in Japan in 2004 with 37 bedridden older patients at risk of pressure ulcer development. The dressing was randomly applied to the right or left greater trochanter for 3 weeks. No dressing was applied to the opposite side as a control. The skin was monitored weekly during the 3-week application for persistent erythema and pressure ulcer development. Skin hydration and pH were also assessed during the intervention and for 1 week after dressing removal. The incidence of persistent erythema was significantly lower in the intervention area than the control area [P = 0.007, RR 0.18 (95% CI: 0.05-0.73) and NNT 4.11 (2.50-11.63) ]. No pressure ulcers occurred in either the intervention or control area. Skin hydration increased significantly during dressing application and remained high after removal (P < 0.001) relative to the control area. Skin pH decreased significantly during the application (P < 0.001) but returned to control levels after removal (P = 0.38). This safe and effective dressing can be used for patients with highly prominent bones and dry skin to prevent pressure ulcers.
Patients' attitudes toward the attire of male physicians: a single-center study in Saudi Arabia.
Batais, Mohammad Ali
2014-01-01
The doctor-patient relationship has been influenced by the appearance of physicians, and there is an association between a physician's physical appearance and the patients' initial perceptions of physician competence. This study aims to explore patients' preferences toward the attire of a male physician, and to examine if a physician's choice of uniform influences the degree of trust, confidence, and follow-up care among respondents. A cross-sectional survey conducted among patients of the Alwazarat family medicine center in Riyadh, Saudi Arabia. A self-administered questionnaire was completed by 300 patients (50% were male and 83.6% had received a secondary education; the mean age was 33.4 [10.1] years) in the Alwazarat family medicine center in Riyadh. The questionnaire was also customized for the local setting with the inclusion of photos of a male doctor in Saudi Arabian national costume, and 3 other dress styles (Western dress with white coat, scrubs with white coat, and scrubs only). Overall, across all questions regarding physician dress style preferences, participants significantly preferred Western dress (39.9%, P < .001), followed by Saudi national dress (26.3%), a scrub suit with a white coat (22.3%), and scrubs only (11.5%). Respondents reported that they were more likely to follow medical advice and would return for follow-up care if a physician wore Western dress. They were significantly more willing to share their social, sexual, and psychological problems with a physician wearing Saudi national dress (P < .001). The importance of a physician's appearance was ranked significantly higher by older patients (P=.002). Respondents were more likely to favor a physician wearing Western attire with a white coat. However, Saudi national dress, followed by Western dress, is the preferred attire when physicians are dealing with social, sexual, and psychological problems.
Chin, Chai-Yee; Jalil, Juriyati; Ng, Pei Yuen; Ng, Shiow-Fern
2018-02-15
M.oleifera is a medicinal plant traditionally used for skin sores, sore throat and eye infections. Recently, the wound healing property of the leaves of M. oleifera was has been well demonstrated experimentally in both in vivo and in vitro models. However, there is a lack of research which focuses on formulating M.oleifera into a functional wound dressing. In this study, the M.oleifera leaf standardized aqueous extract with highest potency in vitro migration was formulated into a film for wound healing application. Firstly, M. oleifera leaf were extracted in various solvents (aqueous, 50%, 70% and 100% ethanolic extracts) and standardized by reference standards using UHPLC technique. The extracts were then tested for cell migration and proliferation using HDF and HEK cell lines. M. oleifera leaf aqueous extract was then incorporated into alginate-pectin (SA-PC) based film dressing. The film dressings were characterized for the physicochemical properties and the bioactives release from the M. oleifera leaf extract loaded film dressing was also investigated using Franz diffusion cells. All extracts were found to contain vicenin-2, chlorogenic acid, gallic acid, quercetin, kaempferol, rosmarinic acid and rutin. Among all M. oleifera extracts, aqueous standardized leaf extracts showed the highest human dermal fibroblast and human keratinocytes cells proliferation and migration properties. Among the film formulations, SA-PC (3% w/v) composite film dressing containing M. oleifera aqueous leaf extract was found to possess optimal physicochemical properties as wound dressing. A potentially applicable wound dressing formulated as an alginate-pectin film containing aqueous extracts of M. oleifera has been developed. The dressing would be suitable for wounds with moderate exudates. Copyright © 2017 Elsevier B.V. All rights reserved.
Biffi, Roberto; Fattori, Luca; Bertani, Emilio; Radice, Davide; Rotmensz, Nicole; Misitano, Pasquale; Cenciarelli, Sabine; Chiappa, Antonio; Tadini, Liliana; Mancini, Marina; Pesenti, Giovanni; Andreoni, Bruno; Nespoli, Angelo
2012-05-23
An antimicrobial dressing containing ionic silver was found effective in reducing surgical-site infection in a preliminary study of colorectal cancer elective surgery. We decided to test this finding in a randomized, double-blind trial. Adults undergoing elective colorectal cancer surgery at two university-affiliated hospitals were randomly assigned to have the surgical incision dressed with Aquacel Ag Hydrofiber dressing or a common dressing. To blind the patient and the nursing and medical staff to the nature of the dressing used, scrub nurses covered Aquacel Ag Hydrofiber with a common wound dressing in the experimental arm, whereas a double common dressing was applied to patients of control group. The primary end-point of the study was the occurrence of any surgical-site infection within 30 days of surgery. A total of 112 patients (58 in the experimental arm and 54 in the control group) qualified for primary end-point analysis. The characteristics of the patient population and their surgical procedures were similar. The overall rate of surgical-site infection was lower in the experimental group (11.1% center 1, 17.5% center 2; overall 15.5%) than in controls (14.3% center 1, 24.2% center 2, overall 20.4%), but the observed difference was not statistically significant (P = 0.451), even with respect to surgical-site infection grade 1 (superficial) versus grades 2 and 3, or grade 1 and 2 versus grade 3. This randomized trial did not confirm a statistically significant superiority of Aquacel Ag Hydrofiber dressing in reducing surgical-site infection after elective colorectal cancer surgery. Clinicaltrials.gov: NCT00981110.
Payne, Caroline; Edwards, Daren
2014-01-01
Objectives: Traumatic wounds and surgery inherently have their complications. Localized infections, wound dehiscence, and excessive wound leakage can be devastating to the patient with a prolonged recovery, but it is also costly to the hospital with an increased length of stay, extra workload, and dressing changes. The single use PICO (Smith and Nephew Healthcare, Hull, United Kingdom) negative pressure wound therapy (NPWT) dressing has revolutionized our management of various acute, chronic, and high output wounds. It requires fewer dressing changes than conventional practice, is used in the outpatient setting, and is a necessary adjuvant therapy to hasten wound healing. Aims: To observe the efficacy of the PICO vacuum-assisted healing within a cost improvement programme. Settings: Plastic surgery department, Royal London Hospital. Materials and Methods: Twenty-one patients with a diversity of postoperative or posttraumatic wounds were considered suitable for PICO application and treated totally on an outpatient basis once the PICO dressing was applied. All wounds were then subjected to continued PICO dressings until healed. Results: All patients tolerated the PICO well with no dressing failure or failure to comply. The number of dressings per patient ranged from 1 to 7. The cost per patient of treatment ranged from £120 to £1578. Estimated cost of all PICO dressing for 21 patients including plastic surgery dressing clinic appointments = £13,345. Median length of treatment to healing (days) = 16; standard deviation = 9.5. Eight patients would have had an inpatient bed stay with conventional therapy, total 24 bed days saved at Bartshealth @£325 per day. Conclusions: The outpatient application of a disposable NPWT can benefit a wide range of clinical wounds that optimizes patient care, promotes rapid wound healing, and importantly helps manage costs. PMID:24917894
Devices and dressings to secure peripheral venous catheters to prevent complications.
Marsh, Nicole; Webster, Joan; Mihala, Gabor; Rickard, Claire M
2015-06-12
A peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PVC to fall out, leading to complications such as phlebitis (irritation or inflammation to the vein wall), infiltration (fluid leaking into surrounding tissues) or occlusion (blockage). An inadequately secured PVC also increases the risk of catheter-related bloodstream infection (CRBSI), as the pistoning action (moving back and forth in the vein) of the catheter can allow migration of organisms along the catheter and into the bloodstream. Despite the many dressings and securement devices available, the impact of different securement techniques for increasing PVC dwell time is still unclear; there is a need to provide guidance for clinicians by reviewing current studies systematically. To assess the effects of PVC dressings and securement devices on the incidence of PVC failure. We searched the following electronic databases to identify reports of relevant randomised controlled trials (RCTs): the Cochrane Wounds Group Register (searched 08 April 2015): The Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (1946 to March 7 2015); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, March 7 2015); Ovid EMBASE (1974 to March 7 2015); and EBSCO CINAHL (1982 to March 8 2015). RCTs or cluster RCTs comparing different dressings or securement devices for the stabilisation of PVCs. Cross-over trials were ineligible for inclusion, unless data for the first treatment period could be obtained. Two review authors independently selected studies, assessed trial quality and extracted data. We contacted study authors for missing information. We used standard methodological procedures expected by Cochrane. We included six RCTs (1539 participants) in this review. Trial sizes ranged from 50 to 703 participants. These six trials made four comparisons, namely: transparent dressings versus gauze; bordered transparent dressings versus a securement device; bordered transparent dressings versus tape; and transparent dressing versus sticking plaster. There is very low quality evidence of fewer catheter dislodgements or accidental removals with transparent dressings compared with gauze (two studies, 278 participants, RR 0.40; 95% CI 0.17 to 0.92, P = 0.03%). The relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47 to 1.68) and infiltration (RR 0.80; 95% CI 0.48 to 1.33) are unclear. The relative effects on PVC failure of a bordered transparent dressing and a securement device have been assessed in only one small study and these were unclear. There was very low quality evidence from the same single study of less frequent dislodgement or accidental catheter removal with bordered transparent dressings than securement devices (RR 0.14, 95% CI 0.03 to 0.63) but more phlebitis with bordered dressings (RR 8.11, 95% CI 1.03 to 64.02) (very low quality evidence). A small single study compared bordered transparent dressings with tape and found very low quality evidence of more PVC failure with the bordered dressing (RR 1.84, 95% CI 1.08 to 3.11) but the relative effects on dislodgement were not clear (very low quality evidence). The relative effects of transparent dressings and a sticking plaster have only been compared in one small study and are unclear. More high quality RCTs are required to determine the relative effects of alternative PVC dressings and securement devices. It is not clear if any one dressing or securement device is better than any other in securing peripheral venous catheters. There is a need for further, independent high quality trials to evaluate the many traditional as well as the newer, high use products. Given the large cost differences between some different dressings and securement devices, future trials should include a robust cost-effectiveness analysis.
OpenFOAM Modeling of Particle Heating and Acceleration in Cold Spraying
NASA Astrophysics Data System (ADS)
Leitz, K.-H.; O'Sullivan, M.; Plankensteiner, A.; Kestler, H.; Sigl, L. S.
2018-01-01
In cold spraying, a powder material is accelerated and heated in the gas flow of a supersonic nozzle to velocities and temperatures that are sufficient to obtain cohesion of the particles to a substrate. The deposition efficiency of the particles is significantly determined by their velocity and temperature. Particle velocity correlates with the amount of kinetic energy that is converted to plastic deformation and thermal heating. The initial particle temperature significantly influences the mechanical properties of the particle. Velocity and temperature of the particles have nonlinear dependence on the pressure and temperature of the gas at the nozzle entrance. In this contribution, a simulation model based on the reactingParcelFoam solver of OpenFOAM is presented and applied for an analysis of particle velocity and temperature in the cold spray nozzle. The model combines a compressible description of the gas flow in the nozzle with a Lagrangian particle tracking. The predictions of the simulation model are verified based on an analytical description of the gas flow, the particle acceleration and heating in the nozzle. Based on experimental data, the drag model according to Plessis and Masliyah is identified to be best suited for OpenFOAM modeling particle heating and acceleration in cold spraying.
NASA Astrophysics Data System (ADS)
Kromer, R.; Danlos, Y.; Costil, S.
2018-04-01
Cold spraying enables a variety of metals dense coatings onto metal surfaces. Supersonic gas jet accelerates particles which undergo with the substrate plastic deformation. Different bonding mechanisms can be created depending on the materials. The particle-substrate contact time, contact temperature and contact area upon impact are the parameters influencing physicochemical and mechanical bonds. The resultant bonding arose from plastic deformation of the particle and substrate and temperature increasing at the interface. The objective was to create specific topography to enable metallic particle adhesion onto ceramic substrates. Ceramic did not demonstrate deformation during the impact which minimized the intimate bonds. Laser surface texturing was hence used as prior surface treatment to create specific topography and to enable mechanical anchoring. Particle compressive states were necessary to build up coating. The coating deposition efficiency and adhesion strength were evaluated. Textured surface is required to obtain strong adhesion of metallic coatings onto ceramic substrates. Consequently, cold spray coating parameters depend on the target material and a methodology was established with particle parameters (diameters, velocities, temperatures) and particle/substrate properties to adapt the surface topography. Laser surface texturing is a promising tool to increase the cold spraying applications.
González, Arturo
2016-01-01
This case study describes treatment for a 52-year-old man with a recurrent venous leg ulcer using a collagen dressing with extracellular matrix. The patient was admitted to the wound care service for a 3-week-old recurrent venous ulcer. Treatment included application of a collagen dressing with extracellular matrix twice weekly or as needed by the patient; application of a secondary dressing (4 × 4 gauze); and coverage with an expandable netting or gauze using a conforming stretch gauze bandage and latex-free dressing retention tape. The initial venous leg ulcer in this patient required 10 weeks to achieve closure. Ninety-eight percent resolution of the recurrent ulcer had occurred within 4 weeks of treatment, with complete closure at 7 weeks. The average healing time for recurrent venous ulcers is reported in the literature to be longer than initial venous ulcers. In the case provided, collagen ECM dressings promoted complete wound healing in 49 days.
Application of VitaVallis dressing for infected wounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirilova, N. V., E-mail: n.kirilova@vitavallis.com; Fomenko, A. N., E-mail: alserova@ispms.tsc.ru; Korovin, M. S., E-mail: msk@ispms.tsc.ru
Today there is a growing demand for safe and efficient antimicrobial dressings for infected wound treatment. The antimicrobial sorption material for VitaVallis dressings was produced by one-stage oxidation of aluminum nanopowder in water in the presence of fibrous acetylcellulose matrix. Scanning electron microscopy revealed that the material is made up of fibers of diameter 1.5–3.0 µm with adhered agglomerated alumina nanosheets. An antimicrobial study revealed a high inhibitory effect of VitaVallis against the growth of gram-negative (E.coli, P. aeruginosa) and gram-positive (S. aureus) strains. The antimicrobial activity of the dressing against microbial pathogens on the wound surface was demonstrated in inmore » vivo experiments on male rats. The dressing was also tested on volunteer patients. The testing showed reduction of the wound healing period, accelerated cleaning of the infected wound and enhanced tissue regeneration in the wound. The results demonstrate that the VitaVallis dressing can be used for the treatment of deep infected wounds.« less
Waring, Mike; Bielfeldt, Stephan; Mätzold, Katja; Wilhelm, Klaus-Peter
2013-02-01
Chronic wounds require frequent dressing changes. Adhesive dressings used for this indication can be damaging to the stratum corneum, particularly in the elderly where the skin tends to be thinner. Understanding the level of damage caused by dressing removal can aid dressing selection. This study used a novel methodology that applied a stain to the skin and measured the intensity of that stain after repeated application and removal of a series of different adhesive types. Additionally, a traditional method of measuring skin barrier damage (transepidermal water loss) was also undertaken and compared with the staining methodology. The staining methodology and measurement of transepidermal water loss differentiated the adhesive dressings, showing that silicone adhesives caused least trauma to the skin. The staining methodology was shown to be as effective as transepidermal water loss in detecting damage to the stratum corneum and was shown to detect disruption of the barrier earlier than the traditional technique. © 2012 John Wiley & Sons A/S.
Controlled trial of Iodosorb in chronic venous ulcers.
Ormiston, M C; Seymour, M T; Venn, G E; Cohen, R I; Fox, J A
1985-01-01
Cadexomer iodine (Iodosorb) is a hydrophilic starch powder containing iodine, which is a suitable dressing for granulating wounds such as venous ulcers. A total of 61 outpatients with chronic venous ulcers participated in a randomised optional crossover trial using cadexomer iodine or a standard dressing for their ulcers. The trial lasted for 24 weeks or until the ulcer had healed. Two patients withdrew during the course of the trial. Both treatments were highly effective, but the epithelium of ulcers dressed with cadexomer iodine grew again significantly faster (p less than 0.001). At the midpoint of the trial (12th week) 13 of 30 patients receiving standard treatment were changed to cadexomer iodine, while only three of 29 receiving cadexomer iodine changed to the standard dressing (p less than 0.02). In most cases ulcers were dressed and rebandaged daily by the patients themselves after instruction and supervision. This may be better than having dressings and bandages applied by professionals less regularly. PMID:3926169
Gelam (Melaleuca spp.) Honey-Based Hydrogel as Burn Wound Dressing
Mohd Zohdi, Rozaini; Abu Bakar Zakaria, Zuki; Yusof, Norimah; Mohamed Mustapha, Noordin; Abdullah, Muhammad Nazrul Hakim
2012-01-01
A novel cross-linked honey hydrogel dressing was developed by incorporating Malaysian honey into hydrogel dressing formulation, cross-linked and sterilized using electron beam irradiation (25 kGy). In this study, the physical properties of the prepared honey hydrogel and its wound healing efficacy on deep partial thickness burn wounds in rats were assessed. Skin samples were taken at 7, 14, 21, and 28 days after burn for histopathological and molecular evaluations. Application of honey hydrogel dressings significantly enhanced (P < 0.05) wound closure and accelerated the rate of re-epithelialization as compared to control hydrogel and OpSite film dressing. A significant decrease in inflammatory response was observed in honey hydrogel treated wounds as early as 7 days after burn (P < 0.05). Semiquantitative analysis using RT-PCR revealed that treatment with honey hydrogel significantly (P < 0.05) suppressed the expression of proinflammatory cytokines (IL-1α, IL-1β, and IL-6). The present study substantiates the potential efficacy of honey hydrogel dressings in accelerating burn wound healing. PMID:21941590
EL Omairi, Nissrine; Abourazzak, Sanae; Chaouki, Sanae; Atmani, Samir; Hida, Moustapha
2014-01-01
Drug-induced hypersensitivity or Drug Reaction with Eosinophilia and Systemic Symptom (DRESS) is a severe adverse drug-induced reaction. Diagnosing DRESS is challenging due to the diversity of cutaneous eruption and organs involved. Most of the aromatic anticonvulsants, such as phenytoin, phenobarbital, and carbamazepine, can induce DRESS. Culprit drug withdrawal and corticosteroids constituted the mainstay of DRESS treatment. We describe a 6 year-old boy who presented fever and rash 4 weeks after starting carbamazepine. Investigation revealed leukocytosis, atypical lymphocytosis, and elevated serum transaminases. The diagnosis of DREES syndrome was made, Carbamazepine was stopped and replaced initially by Clobazam and by Valproic acid after discharge, no systemic corticotherapy was prescribed. Symptoms began to resolve within two weeks, and by one month later her laboratory values had returned to normal. The aim of this work is to raise awareness general practitioner and pediatricians to suspect Dress syndrome in patients who present with unusual complaints and skin findings after starting any antiepileptic drug. PMID:25360193
Evaluation of a honey-impregnated tulle dressing in primary care.
Stephen-Haynes, Jackie
2004-06-01
Honey has been used for its healing properties for centuries and has been used to dress wounds with favourable results. The emergence of antibiotic resistance and growing interest in "natural" or "complementary" therapies has led to an interest in honey dressings. Much of the research to date has been related to honey's antibacterial properties. However, the healing properties claimed for honey also include stimulating new tissue growth, moist wound healing, fluid handling and promoting epithelialization. Until recently, honey had not been developed as a wound management product and was not a certified pharmaceutical device. Activon Tulle is a sterile, non-adherent dressing impregnated with Leptospermum scoparium hone. The claimed properties of honey dressings would make this a valuable addition to the dressing currently available in the primary care setting. An evaluation was undertaken involving 20 patients with a variety of wounds. A conclusion is drawn that while further research is needed, medical grade honey does appear to be a valuable addition to the wound management formulary.
Reducing pain during the removal of adhesive and adherent products.
Denyer, Jacqueline
Silicone Medical Adhesive Removers (SMARs) have proved a valuable addition to formularies. In the absence of SMARs, trauma following removal of adhesive dressings, ostomy products, retention tapes and monitoring equipment can lead to skin stripping or extension of existing wounds. Those at increased risk of skin stripping include groups such as older people, premature infants and neonates and those with skin fragility syndromes. Appeel® Sterile Sachet (CliniMed) is a sterile SMAR in liquid form supplied in a single-use sachet. The addition of this sterile product to the existing Appeel range of wipes and aerosols provides an adhesive remover suitable for use on broken skin. Unlike delivery from an aerosol, Appeel Sterile Sachet does not feel cold on application, a sensation which can be confused with pain. This article discusses the value of SMARs and in particular the advantages of using the single-use Appeel Sterile Sachet.
Minor burn management: potions and lotions
Hyland, Ela J; Connolly, Siobhan M; Fox, Jade A; Harvey, John G
2015-01-01
Summary The first aid for burns is to run cold water over the burn for 20 minutes. This is effective for up to three hours after the injury. Assess the affected body surface area using the rule of nines. Consult a burn unit if more than 5% of the total body surface area is burnt in a child or if more than 10% in an adult. Extensive or deep burns and burns to special areas, such as the hands, should be referred. Chemical or electrical burns should also be assessed by a burn unit. For minor burns, antimicrobial dressings are recommended, but oral antibiotics should be avoided unless there are signs of infection. As burns are tetanus prone, check the patient’s immunisation status. Burns that become infected or are slow to heal should be discussed with a burn unit. The burn unit can also provide advice if there are uncertainties about how to manage a patient. PMID:26648640
Spin-orbit coupling in ultracold Fermi gases of 173Yb atoms
NASA Astrophysics Data System (ADS)
Song, Bo; He, Chengdong; Hajiyev, Elnur; Ren, Zejian; Seo, Bojeong; Cai, Geyue; Amanov, Dovran; Zhang, Shanchao; Jo, Gyu-Boong
2017-04-01
Synthetic spin-orbit coupling (SOC) in cold atoms opens an intriguing new way to probe nontrivial topological orders beyond natural conditions. Here, we report the realization of the SOC physics both in a bulk system and in an optical lattice. First, we demonstrate two hallmarks induced from SOC in a bulk system, spin dephasing in the Rabi oscillation and asymmetric atomic distribution in the momentum space respectively. Then we describe the observation of non-trivial spin textures and the determination of the topological phase transition in a spin-dependent optical lattice dressed by the periodic Raman field. Furthermore, we discuss the quench dynamics between topological and trivial states by suddenly changing the band topology. Our work paves a new way to study non-equilibrium topological states in a controlled manner. Funded by Croucher Foundation and Research Grants Council (RGC) of Hong Kong (Project ECS26300014, GRF16300215, GRF16311516, and Croucher Innovation Grants).
Effects of wound dressings on cultured primary keratinocytes.
Esteban-Vives, Roger; Young, Matthew T; Ziembicki, Jenny; Corcos, Alain; Gerlach, Jörg C
2016-02-01
Autologous cell-spray grafting of non-cultured epidermal cells is an innovative approach for the treatment of severe second-degree burns. After treatment, wounds are covered with dressings that are widely used in wound care management; however, little is known about the effects of wound dressings on individually isolated cells. The sprayed cells have to actively attach, spread, proliferate, and migrate in the wound for successful re-epithelialization, during the healing process. It is expected that exposure to wound dressing material might interfere with cell survival, attachment, and expansion. Two experiments were performed to determine whether some dressing materials have a negative impact during the early phases of wound healing. In one experiment, freshly isolated cells were seeded and cultured for one week in combination with eight different wound dressings used during burn care. Cells, which were seeded and cultured with samples of Adaptic(®), Xeroform(®), EZ Derm(®), and Mepilex(®) did not attach, nor did they survive during the first week. Mepitel(®), N-Terface(®), Polyskin(®), and Biobrane(®) dressing samples had no negative effect on cell attachment and cell growth when compared to the controls. In a second experiment, the same dressings were exposed to pre-cultured cells in order to exclude the effects of attachment and spreading. The results confirm the above findings. This study could be of interest for establishing skin cell grafting therapies in burn medicine and also for wound care in general. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Efficacy of a surfactant-based wound dressing on biofilm control.
Percival, Steven L; Mayer, Dieter; Salisbury, Anne-Marie
2017-09-01
The aim of this study was to evaluate the efficacy of both a nonantimicrobial and antimicrobial (1% silver sulfadiazine-SSD) surfactant-based wound dressing in the control of Pseudomonas aeruginosa, Enterococcus sp, Staphylococcus epidermidis, Staphylococcus aureus, and methicillin-resistant S. aureus (MRSA) biofilms. Anti-biofilm efficacy was evaluated in numerous adapted American Standards for Testing and Materials (ASTM) standard biofilm models and other bespoke biofilm models. The ASTM standard models employed included the Minimum biofilm eradication concentration (MBEC) biofilm model (ASTM E2799) and the Centers for Disease Control (CDC) biofilm reactor model (ASTM 2871). Such bespoke biofilm models included the filter biofilm model and the chamberslide biofilm model. Results showed complete kill of microorganisms within a biofilm using the antimicrobial surfactant-based wound dressing. Interestingly, the nonantimicrobial surfactant-based dressing could disrupt existing biofilms by causing biofilm detachment. Prior to biofilm detachment, we demonstrated, using confocal laser scanning microscopy (CLSM), the dispersive effect of the nonantimicrobial surfactant-based wound dressing on the biofilm within 10 minutes of treatment. Furthermore, the non-antimicrobial surfactant-based wound dressing caused an increase in microbial flocculation/aggregation, important for microbial concentration. In conclusion, this nonantimicrobial surfactant-based wound dressing leads to the effective detachment and dispersion of in vitro biofilms. The use of surfactant-based wound dressings in a clinical setting may help to disrupt existing biofilm from wound tissue and may increase the action of antimicrobial treatment. © 2017 by the Wound Healing Society.
N-Halamine Biocidal Materials with Superior Antimicrobial Efficacies for Wound Dressings.
Demir, Buket; Broughton, Roy M; Qiao, Mingyu; Huang, Tung-Shi; Worley, S D
2017-09-21
This work demonstrated the successful application of N-halamine technology for wound dressings rendered antimicrobial by facile and inexpensive processes. Four N-halamine compounds, which possess different functional groups and chemistry, were synthesized. The N-halamine compounds, which contained oxidative chlorine, the source of antimicrobial activity, were impregnated into or coated onto standard non-antimicrobial wound dressings. N-halamine-employed wound dressings inactivated about 6 to 7 logs of Staphylococcus aureus and Pseudomonas aeruginosa bacteria in brief periods of contact time. Moreover, the N-halamine-modified wound dressings showed superior antimicrobial efficacies when compared to commercially available silver wound dressings. Zone of inhibition tests revealed that there was no significant leaching of the oxidative chlorine from the materials, and inactivation of bacteria occurred by direct contact. Shelf life stability tests showed that the dressings were stable to loss of oxidative chlorine when they were stored for 6 months in dark environmental conditions. They also remained stable under florescent lighting for up to 2 months of storage. They could be stored in opaque packaging to improve their shelf life stabilities. In vitro skin irritation testing was performed using a three-dimensional human reconstructed tissue model (EpiDerm™). No potential skin irritation was observed. In vitro cytocompatibility was also evaluated. These results indicate that N-halamine wound dressings potentially can be employed to prevent infections, while at the same time improving the healing process by eliminating undesired bacterial growth.
Dressing wear time after breast reconstruction: study protocol for a randomized controlled trial
2013-01-01
Background One of the major risk variables for surgical site infection is wound management. Understanding infection risk factors for breast operations is essential in order to develop infection-prevention strategies and improve surgical outcomes. The aim of this trial is to assess the influence of dressing wear time on surgical site infection rates and skin colonization. Patients’ perception at self-assessment will also be analyzed. Methods/Design This is a two-arm randomized controlled trial. Two hundred breast cancer patients undergoing immediate or delayed breast reconstruction will be prospectively enrolled. Patients will be randomly allocated to group I (dressing removed on postoperative day one) or group II (dressing removed on postoperative day six). Surgical site infections will be defined by standard criteria from the Centers for Disease Control and Prevention (CDC). Skin colonization will be assessed by culture of samples collected at predefined time points. Patients will score dressing wear time with regard to safety, comfort and convenience. Discussion The evidence to support dressing standards for breast surgery wounds is empiric and scarce. CDC recommends protecting, with a sterile dressing for 24 to 48 hours postoperatively, a primarily closed incision, but there is no recommendation to cover this kind of incision beyond 48 hours, or on the appropriate time to shower or bathe with an uncovered incision. The results of the ongoing trial may support standard recommendations regarding dressing wear time after breast reconstruction. Trial registration ClinicalTrials.gov identifier: http://NCT01148823. PMID:23432779
Jin, Sung Giu; Yousaf, Abid Mehmood; Kim, Kyeong Soo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jin Ki; Yong, Chul Soon; Youn, Yu Seok; Kim, Jong Oh; Choi, Han-Gon
2016-03-30
The purpose of this study was to investigate the influence of different hydrophilic polymers on the swelling, bioadhesion and mechanical strength of hydrocolloid wound dressings (HCDs) in order to provide an appropriate composition for a hydrocolloid wound dressing system. In this study, the HCDs were prepared with styrene-isoprene-styrene copolymer (SIS) and polyisobutylene (PIB) as the base using a hot melting method. Additionally, numerous SIS/PIB-based HCDs were prepared with six hydrophilic polymers, and their wound dressing properties were assessed. Finally, the wound healing efficacy of the selected formulations was compared to a commercial wound dressing. The swelling ratio, bioadhesive force and mechanical strengths of HCDs were increased in the order of sodium alginate>sodium CMC=poloxamer=HPMC>PVA=PVP, sodium alginate>sodium CMC=poloxamer>PVA>HPMC=PVP and sodium alginate≥PVA>PVP=HPMC=sodium CMC>poloxamer, respectively. Among the hydrophilic polymers tested, sodium alginate most enhanced the swelling capacity, bioadhesive force and mechanical strengths. Thus, the hydrophilic polymers played great role in the swelling, bioadhesion and mechanical strength of SIS/PIB-based HCDs. The HCD formulation composed of PIB, SIS, liquid paraffin and sodium alginate at the weight ratio of 20/25/12/43 gave better wound dressing properties and more excellent wound healing efficacy than the commercial wound dressing. Therefore, the novel HCD formulation could be a promising hydrocolloid system for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.
A Wireless Electroceutical Dressing Lowers Cost of Negative Pressure Wound Therapy
Ghatak, Piya Das; Schlanger, Richard; Ganesh, Kasturi; Lambert, Lynn; Gordillo, Gayle M.; Martinsek, Patsy; Roy, Sashwati
2015-01-01
Objective: To test whether the use of a wireless electroceutical dressing (WED) (Procellera®) in conjunction with a 5-day negative pressure wound therapy (NPWT) may reduce the number of dressing changes required per week with this therapy. Approach: At the Ohio State University Comprehensive Wound Center, chronic wound patients (n=30) undergoing NPWT were randomized into two arms following consent as approved by the institutional review board. The control arm received standard of care NPWT, where the dressing change was performed thrice a week. The test arm received the same care except that the WED was added as an interface layer and dressing change was limited to twice a week. Results: A reduced cost of care was achieved using the WED in conjunction with NPWT. Despite fewer dressing changes in wounds dressed with the WED, closure outcomes were comparable with no overt signs of any wound complication, including infection. The cost of NPWT care during the week was significantly lower (from $2918 to $2346) in the WED-treated group compared with patients in the control arm. Innovation: This work introduces a novel technology platform involving a WED, which may be used in conjunction with NPWT. If used as such, NPWT is effective in decreasing the frequency of dressing change and lowering the cost of care. Conclusion: This work points toward the benefit of using the WED combined with NPWT. A larger clinical trial investigating the cost-effectiveness of WED in wound care is warranted. PMID:26005596
DEVELOPMENT OF A NEXT-GENERATION ANTIMICROBIAL WOUND DRESSING.
Metcalf, Daniel; Parsons, David; Bowler, I Philip
2016-03-01
Delayed wound healing due to infection is a burden on healthcare systems, and the patient and caregiver alike. An emerging factor in infection and delayed healing is the presence development of biofilm in wounds. Biofilm is communities of microorganisms, protected by an extracellular matrix of slime in the wound, which can tolerate host defences and applied antimicrobials such as antibiotics or antimicrobial dressings. A growing evidence base exists suggesting that biofilm exists in a majority of chronic wounds, and can be a precursor to infection while causing delayed healing itself. In vivo models have demonstrated that the inflammatory, granulation and epithelialization processes of normal wound healing are impaired by biofilm presence. The challenge in the development of a new antimicrobial wound dressing was to make standard antimicrobial agents more effective against biofilm, and this was answered following extensive biofilm research and testing. A combination of metal chelator, surfactant and pH control displayed highly synergistic anti-biofilm action with 1.2% ionic silver in a carboxymethylcellulose dressing. Its effectiveness was challenged and proven in complex in vitro and in vivo wound biofilm models, followed by clinical safety and performance demonstrations in a 42-patient study and 113 clinical evaluations. Post-market surveillance was conducted on the commercially available dressing, and in a 112-case evaluation, the dressing was shown to effectively manage exudate and suspected biofilm while shifting difficult-to-heal wounds onto healing trajectories, after an average of 4 weeks of new dressing use in otherwise standard wound care protocols. This was accompanied by a low frequency of dressing related adverse events. In a second evaluation, clinical signs of infection and wound dimension data, before and after the evaluations, were also available. Following an average of 5.4 weeks of dressing use, all signs of clinical infection were reduced, from an average frequency of 36% to 21%. An average of 62% wound size reduction was achieved, with 90% of wounds reducing in size and 10 wounds healing completely. The new clinical evidence for this next-generation antimicrobial wound dressing suggests it is safe and effective at managing exudate, infection and biofilm, while it can shift established, stubborn wounds onto healing trajectories. The scientific rationale for this new dressing technology is supported by in vitro and in vivo evidence, so now further comparative, randomized and outcome-based clinical studies are required to fully understand the clinical and economic benefits this new dressing technology can bring.
Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.
Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M
2015-07-01
Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were no readmissions for further debridement or skin grafting. Our experience shows that patients may be discharged shortly after the application of the copolymer dressing, with manageable pain scores and ease of use as determined by the caretakers high satisfaction. This new, fully synthetic copolymer dressing is easy to apply, does not require any additional antimicrobial coverage and may be used to successfully manage deeper partial-thickness burns, donor sites or burns in areas of contour, where many other dressings might not be considered or be appropriate. None declared.
Naruse, Koji; Uchino, Masataka; Hirakawa, Noriko; Toyama, Masahiro; Miyajima, Genyo; Mukai, Manabu; Urabe, Ken; Uchida, Kentaro; Itoman, Moritoshi
2016-08-01
We have conducted a basic study on the influences on ultrasonic properties when LIPUS is applied through wound dressing. According to the results of ex vivo experiments conducted to date, LIPUS showed ultrasonic properties such as transmittance, coefficient of transmission, and a non-uniformity ratio through film wound dressing better than other wound dressing, and it was considered that LIPUS's effect for fracture healing was not influenced by film wound dressing. Then, we discussed the influence on the effect of LIPUS through film wound dressing. Thirty male 8-week-old Sprague-Dawley rats were used for the trial. After creating close transverse femoral fractures on the right legs of these 30 rats, they were divided into 3 groups of 10; LIPUS through wound dressing (Group A), LIPUS without wound dressing (Group B), and No LIPUS treatment (Group C). OPSITE Wound, which was thought to have the least influence on ultrasound properties, was used for this trial. Group A and B received LIPUS for 20 minutes a day from the first day after the fractures. LIPUS was generated from Teijin Pharma's device for a basic experiment. When treating Group A, the wound dressing was pasted on the ultrasound terminal in order to apply LIPUS through the dressing. We assessed the time-oriented morphological change of each group in anesthetized condition using simple radiographs on the 8th, 16th, and 24th day after the fractures. Six rats in Group A, 2 in Group B, and 1 in Group C died in anesthesia, and we discussed the remaining 4 rats in Group A, 8 in Group B, and 9 in Group C. We defined more than one teleost callus bridging as bone-union. We also counted a bone remodeling when we recognized the absorption of existing cortical bone and the transformation of new bone to cortical bone in simple radiographs. As a result, compared with Group C, we recognized that both bone union and remodeling accelerated remarkably in Group B, but not in Group A. It suggested that LIPUS through wound dressing had negative influences on both period shorting of fracture healing and bone remodeling. When LIPUS was conducted through film wound dressing, transmittance and coefficient of transmission were unchanged; however, the non-uniformity ratio changed slightly. The non-uniformity ratio of the ultrasound transducer had a significant influence on the effect of LIPUS on fracture healing.
Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin
2016-03-01
Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. Copyright © 2015 Elsevier B.V. All rights reserved.
High-strength bioresorbable Fe–Ag nanocomposite scaffolds: Processing and properties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharipova, Aliya; Skolkovo Institute of Science and Technology, Skolkovo, 143025; Psakhie, Sergey G.
2015-10-27
High strength ductile iron-silver nanocomposite scaffolds were fabricated employing high energy attrition milling of micron-submicron powders, followed by cold sintering/high pressure consolidation. Particulate leaching method with soluble Na{sub 2}SO{sub 4} and K{sub 2}CO{sub 3} salts as porogens was used to create scaffolds with 50, 55, 60 and 73% volume fraction of pores. Part of specimens was annealed at 600, 800 and 900°C. Specimens were characterized employing X-ray diffraction, scanning electron microscopy (SEM) with electron probe microanalysis (EDS) and high resolution SEM. Mechanical properties were measured in compression and permeability was measured in permeameter based on Darcy’s law. Scaffolds with 50%more » and 55% porosity exhibited high compressive strength (18–22 MPa), compressive strength of 8–12 MPa was observed for scaffolds with 73% porosity. Treatments at 800 and 900°C result in increase of strength and ductility with some coarsening of microstructure. Best combination of compressive strength (15 MPa) and permeability (0.6{sup −6} cm{sup 2}) is close to the range of trabecular bone.« less
Modeling of High-Velocity Flows in ITAM Impulse Facilities
2010-04-01
up to 150 ms; Adiabatic compression wind tunnels up to 100 ms; Shock tubes... shock tubes. Basic and applied aerodynamic research has been performed in these wind tunnels in the range of Mach numbers М = 6 20 for many years...passage of a shock wave propagating over a cold rarefied gas filling the wind tunnel . When the gas heated in the shock wave (plug) passes around the
External Catalyst Breakup Phenomena
1975-09-01
thruster exposure. a Erosion .by a pulsed liquid stream at high velocity. * Thermal shock from liquid quench cooldovn. 9 Erosion resulting from solid...the liquid velocity. During a cold start contact with hydrazine leading to liquid wetting can lead to very high internal pressures as a result ot the...compression and final dilation, suggest benefits from reducing this variable. A . Isolating the catalyst particles from one another so as to avoid high
[Use of powder metallurgy for development of implants of Co-Cr-Mo alloy powder].
Dabrowski, J R
2001-04-01
This paper discusses the application of powder metallurgy for the development of porous implantation materials. Powders obtained from Co-Cr-Mo alloy with different carbon content by water spraying and grinding, have been investigated. Cold pressing and rotary re-pressing methods were used for compressing the powder. It was found that the sintered materials obtained from water spraying have the most advantageous properties.
Gesoğlu, Mehmet; Güneyisi, Erhan; Mahmood, Swara Fuad; Öz, Hatice Öznur; Mermerdaş, Kasım
2012-10-15
Ground granulated blast furnace slag (GGBFS), a by-product from iron industry, was recycled as artificial coarse aggregate through cold bonding pelletization process. The artificial slag aggregates (ASA) replaced partially the natural coarse aggregates in production of self-compacting concrete (SCC). Moreover, as being one of the most widely used mineral admixtures in concrete industry, fly ash (FA) was incorporated as a part of total binder content to impart desired fluidity to SCCs. A total of six concrete mixtures having various ASA replacement levels (0%, 20%, 40%, 60%, and 100%) were designed with a water-to-binder (w/b) ratio of 0.32. Fresh properties of self-compacting concretes (SCC) were observed through slump flow time, flow diameter, V-funnel flow time, and L-box filling height ratio. Compressive strength of hardened SCCs was also determined at 28 days of curing. It was observed that increasing the replacement level of ASA resulted in decrease in the amount of superplasticizer to achieve a constant slump flow diameter. Moreover, passing ability and viscosity of SCC's enhanced with increasing the amount of ASA in the concrete. The maximum compressive strength was achieved for the SCC having 60% ASA replacement. Copyright © 2012 Elsevier B.V. All rights reserved.
Head-on collision between positron acoustic waves in homogeneous and inhomogeneous plasmas
NASA Astrophysics Data System (ADS)
Alam, M. S.; Hafez, M. G.; Talukder, M. R.; Ali, M. Hossain
2018-05-01
The head-on collision between positron acoustic solitary waves (PASWs) as well as the production of rogue waves (RWs) in homogeneous and PASWs in inhomogeneous unmagnetized plasma systems are investigated deriving the nonlinear evolution equations. The plasmas are composed of immobile positive ions, mobile cold and hot positrons, and hot electrons, where the hot positrons and hot electrons are assumed to follow the Kappa distributions. The evolution equations are derived using the appropriate coordinate transformation and the reductive perturbation technique. The effects of concentrations, kappa parameters of hot electrons and positrons, and temperature ratios on the characteristics of PASWs and RWs are examined. It is found that the kappa parameters and temperature ratios significantly modify phase shifts after head-on collisions and RWs in homogeneous as well as PASWs in inhomogeneous plasmas. The amplitudes of the PASWs in inhomogeneous plasmas are diminished with increasing kappa parameters, concentration and temperature ratios. Further, the amplitudes of RWs are reduced with increasing charged particles concentration, while it enhances with increasing kappa- and temperature parameters. Besides, the compressive and rarefactive solitons are produced at critical densities from KdV equation for hot and cold positrons, while the compressive solitons are only produced from mKdV equation for both in homogeneous and inhomogeneous plasmas.
Anderson, Robert C.
1986-01-01
A uranium-1 to 3 wt. % zirconium alloy characterized by high strength, high ductility and stable microstructure is fabricated by an improved thermal mechanical process. A homogenous ingot of the alloy which has been reduced in thickness of at least 50% in the two-step forging operation, rolled into a plate with a 75% reduction and then heated in vacuum at a temperature of about 750.degree. to 850.degree. C. and then quenched in water is subjected to further thermal-mechanical operation steps to increase the compressive yield strength approximately 30%, stabilize the microstructure, and decrease the variations in mechanical properties throughout the plate is provided. These thermal-mechanical steps are achieved by cold rolling the quenched plate to reduce the thickness thereof about 8 to 12%, aging the cold rolled plate at a first temperature of about 325.degree. to 375.degree. C. for five to six hours and then aging the plate at a higher temperature ranging from 480.degree. to 500.degree. C. for five to six hours prior to cooling the billet to ambient conditions and sizing the billet or plate into articles provides the desired increase in mechanical properties and phase stability throughout the plate.
Multi-Mbar Ramp Compression of Copper
NASA Astrophysics Data System (ADS)
Kraus, Rick; Davis, Jean-Paul; Seagle, Christopher; Fratanduono, Dayne; Swift, Damian; Eggert, Jon; Collins, Gilbert
2015-06-01
The cold curve is a critical component of equation of state models. Diamond anvil cell measurements can be used to determine isotherms, but these have generally been limited to pressures below 1 Mbar. The cold curve can also be extracted from Hugoniot data, but only with assumptions about the thermal pressure. As the National Ignition Facility will be using copper as an ablator material at pressures in excess of 10 Mbar, we need a better understanding of the high-density equation of state. Here we present ramp-wave compression experiments at the Sandia Z-Machine that we have used to constrain the isentrope of copper to a stress state of nearly 5 Mbar. We use the iterative Lagrangian analysis technique, developed by Rothman and Maw, to determine the stress-strain path. We also present a new iterative forward analysis (IFA) technique coupled to the ARES hydrocode that performs a non-linear optimization over the pressure drive and equation of state in order to match the free surface velocities. The IFA technique is an advantage over iterative Lagrangian analysis for experiments with growing shocks or systems with time dependent strength, which violate the assumptions of iterative Lagrangian analysis. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hora, H.
1976-02-01
The nonlinear interaction force between intense laser fields and cold plasma shells efficiently transforms radiant energy into mechanical energy of implosion. This transfer of energy has been considered before in numerical experiments and it is treated here analytically in a didactic example starting with an inhomogeneous Rayleigh density profile. Up to 50% of the laser energy can be transformed into the energy of compression if a single ''untailored'' pulse of 2.5 x 10/sup 16/ W/cm/sup 2/ intensity and of only a few picosecond duration is used for spherical illumination of a shell. If the pulse is short enough to reducemore » collisional thermalization, then the collapse and compression of the plasma can remain at the threshold of Fermi degeneracy and still be adiabatic. This results in nuclear reaction gains G, based on the deposited energy, E/sub 0/, and without ..cap alpha..-particle reheating, of G=400 for E/sub 0/=2.25 kJ ((D--T reaction), 900 kJ (D--D), 13 MJ (H--B). About 1000 times less laser energy is necessary than in the case of gas dynamic ablation resulting in the same nuclear reaction yields. (AIP)« less
Professional Characteristics Communicated by Formal versus Casual Workplace Attire
ERIC Educational Resources Information Center
Cardon, Peter W.; Okoro, Ephraim A.
2009-01-01
Employees are frequently advised to dress for success to build their careers. From the corporate perspective, employees who are well dressed are believed to form better impressions with colleagues, clients, and customers. Many companies create dress codes in order to gain the benefits of a professionally appearing workforce. Developing effective…
Identification of Workplace Dress by Low-Income Job Seekers
ERIC Educational Resources Information Center
Saiki, Diana
2013-01-01
The author examined how low-income job seekers participating in a workplace dress program identified traditional business and business casual dress. Seventy low-income job seekers identified clothing items as traditional business (e.g., suits, ties), similar to identifications made by professionals and image consultants in previous literature.…
ERIC Educational Resources Information Center
Lumsden, Linda; Miller, Gabriel
2002-01-01
Students do not always make choices that adults agree with in their choice of school dress. Dress-code issues are explored in this Research Roundup, and guidance is offered to principals seeking to maintain a positive school climate. In "Do School Uniforms Fit?" Kerry White discusses arguments for and against school uniforms and summarizes the…
Counterconformity: An Attribution Model of Adolescents' Uniqueness-Seeking Behaviors in Dressing
ERIC Educational Resources Information Center
Ling, I-Ling
2008-01-01
This article explores how an attribution model will illustrate uniqueness-seeking behavior in dressing in the Taiwanese adolescent subculture. The study employed 443 senior high school students. Results show that the tendency of uniqueness-seeking behavior in dressing is moderate. However, using cluster analysis to segment the counterconformity…
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
9 CFR 108.9 - Dressing rooms and other facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Dressing rooms and other facilities. 108.9 Section 108.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT... REQUIREMENTS FOR LICENSED ESTABLISHMENTS § 108.9 Dressing rooms and other facilities. Each licensed...
2003-09-01
Pharmaceuticals, Inc. (Westlake, OH), submitted the Hemarrest dressing. This dressing was a thin, sheet-like pad with a mixture of epsilon aminocaproic acid ...chloric acid salt purified bovine corium collagen. It was prepared in a compacted nonwoven web form (7.0 7.0 cm). Ethicon, Inc. (Somerville, NJ...may be related to enhanced platelet procoagulant activity and annexin V binding.46 Another derivative of gallic acid , bis- muth subgallate, appears to
An evaluation of a silicone adhesive shaped heel dressing.
Hampton, Sylvie
Tissue breakdown is complex and involves many factors. Pressure ulcer development in the heels is subject to extrinsic factors such as pressure, shear, friction and moisture. The heels are the most common sites for friction and shear damage, which can lead to blistering, skin erosion and tissue breakdown (Grey et al, 2006). To address the issues of wounds that are painful on dressing removal and friable skin, Smith & Nephew has introduced a soft silicone adhesive dressing to its Allevyn dressing range. Silicone does not adhere to wounded areas and can be removed gently without trauma to the periwound area. This paper discusses the findings of a 20-patient multi-site evaluation examining the performance and acceptability of Allevyn Gentle Border Heel dressing in the management of heel wounds.
The use of prophylactic dressings in the prevention of pressure ulcers: a literature review.
Cornish, Lynn
2017-06-02
Pressure ulcers pose a significant burden to both patients and health care resources. There are an increasing number of studies that have examined the use of prophylactic dressings, and their ability to redistribute pressure and protect the skin from shear and friction damage. This literature review examines six studies conducted on this controversial subject. Brindle and Wegelin ( 2012 ; Chaiken, 2012 ; Cubit et al, 2012 ; Santamaria et al, 2012) all examined the role of dressings to prevent pressure ulcers, and Call et al (2013a ; 2013b ), conducted in vitro research into the mode of dressings. Current research suggests that while further research is required, the use of prophylactic dressings have a place alongside standard measures, in helping to prevent pressure, shear and friction damage.
Wound dressings from naturally-occurring polymers: A review on homopolysaccharide-based composites.
Naseri-Nosar, Mahdi; Ziora, Zyta Maria
2018-06-01
Wound dressings are designed to support the wound bed and protect it from the factors that may delay or impede its healing such as contaminations and moisture-loss, thereby facilitating and accelerating the healing process. The materials used to prepare wound dressings include natural and synthetic polymers, as well as their combinations, in the forms of films, sponges and hydrogels. Polysaccharides are naturally-occurring polymers that have been extensively used as wound dressing materials. Homopolysaccharides are a class of polysaccharides consist of only one type of monosaccharide. The current review intends to overview the studies in which wound dressings from naturally-occurring polymers, based on homopolysaccharides, were prepared and evaluated. Homopolysaccharides such as cellulose, chitosan, chitin, pullulan, starch and β-glucan were considered. Copyright © 2018 Elsevier Ltd. All rights reserved.
She Wears the Pants: The Reform Dress as Technology in Nineteenth-Century America.
Mas, Catherine
This article examines the American dress-reform movement, detailing the ways in which reformers conceptualized clothing as a social and bodily technology. In the mid-nineteenth century, women began making and wearing the "reform dress"-a costume consisting of pants and shortened, lightweight skirts-as an alternative to burdensome feminine fashions. When ridiculed in public for wearing overtly masculine garments, dress reformers insisted their clothing was healthful, functional, and natural. This article discusses women's use of medical science and technical knowledge in their rejection of fashion, promotion of sexual equality, and efforts to change mainstream clothing practices. When approached from a technological perspective, the reform dress reveals broader tensions in an industrializing American society, such as changing gender relations and new understandings of the relationship between humans and technology.
Effect of music intervention on burn patients' pain and anxiety during dressing changes.
Hsu, Kuo-Cheng; Chen, Li Fen; Hsiep, Pi Hsia
2016-12-01
For burn patients, the daily dressing process causes pain and anxiety. Although drugs can relieve them, the degree of pain during dressing changes is often moderate to severe. Therefore, relevant supporting interventions, like music as an ideal intervention, could alleviate the patient's pain. This study investigated the impact of music intervention at dressing change time on burn patients' pain and anxiety. This was a prospective, randomized clinical trial; patients were randomly assigned into control (standard intervention) and experimental groups (crystal music intervention) for five consecutive days (35 patients in each group). Patients' pain and anxiety measurements were collected before, during, and after dressing changes and morphine usage was recorded. The study period was October 2014 to September 2015. There was no difference in morphine dosage for both groups. By the fourth day of music intervention, burn patients' pain before, during, and after dressing changes had significantly decreased; anxiety on the fourth day during and after dressing changes had also significantly decreased. Nurses may use ordered prescription analgesics, but if non-pharmacological interventions are increased, such as providing timely music intervention and creating a friendly, comfortable hospital environment, patients' pain and anxiety will reduce. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Cattelan, Marília Gonçalves; Nishiyama, Yara Paula de Oliveira; Gonçalves, Tânia Maria Vinturim; Coelho, Alexandre Rodrigo
2018-08-01
There is a broad research interest in the search for alternatives to chemical additives for use as natural food preservatives. Although many natural compounds have biological in vitro properties evidenced, in situ studies are still scarce. This study evaluated the effect of oregano essential oil (OEO) and salt (NaCl) concentrations against Escherichia coli (ATCC 8739), in salad dressing, using the response surface methodology. The experiment included a 2 2 central composite rotatable design (CCRD) in a total of 11 formulations of salad dressings. Oregano essential oil was characterized by gas chromatography and salad dressings by ash, lipids, proteins and moisture. OEO was composed mainly by carvacrol (65.1%) and p-cymene (12.0%). Salad dressings showed similar chemical profiles. A mathematical model for the prediction of the antibacterial activity in salad dressing was obtained. The results revealed that the interaction between OEO and salt showed effect on the bacterial count. However, the effect of salt was negative suggesting that the highest NaCl concentrations decreases the bacterial count. Therefore, within the parameters studied, the use of OEO to control E. coli in salad dressing can be considered promising and allows reduction in the levels of salt to be incorporated in food. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sahraro, Maryam; Yeganeh, Hamid; Sorayya, Marziyeh
2016-02-01
Preparation and assessments of novel absorptive wound dressing materials with efficient antimicrobial activity as well as very good cytocompatibility were described in this work. An amine terminated poly(hexamethylene guanidine hydrochloride) was prepared and used as curing agent of different epoxy-terminated polyurethane prepolymers. The structures of prepared materials were elucidated by evaluation of their (1)H NMR and FTIR spectra. The recorded tensile strength of membranes confirmed the excellent dimensional stability of the film type dressings even at fully hydrated conditions. Therefore, these dressings could protect the wound bed from external forces during the healing period. The structurally optimized dressing membranes could preserve the desired moist environment over the wounded area, as a result of their balanced equilibrium, water absorption and water vapor transmission rate. Therefore, a very good condition for stimulation of self-healing of wound bed was attained. Also, owing to the presence of guanidine hydrochloride moieties embedded into the structure of dressings, efficient antimicrobial activity against Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans were detected. In vitro cytotoxicity assay of the prepared dressings revealed cytocompatibility of these materials against fibroblast cells. Therefore, they could support cell growth and proliferation at the wounded area. Copyright © 2015 Elsevier B.V. All rights reserved.
Accidental strangulation of a mentally retarded patient by a clothing collar: a case report.
Hitosugi, Masahito; Yokoyama, Tomoko; Kido, Masahito; Kawato, Hitoshi; Matsushima, Kazumi; Nagai, Toshiaki; Tokudome, Shogo
2006-07-01
A 40-year-old mentally retarded woman died of accidental strangulation in a nursing home. She was found in a kneeling position with her hands on her knees and the collar of her clothing compressing the front and sides of the neck. Before the accident, a nurse had dressed the patient in one-piece overall-style pyjamas put on back to front so that she could not remove the garment herself. The post-mortem findings and reconstruction of the scene of death suggested that the patient had been strangled by the collar of her backward-facing clothing while in a kneeling position. Because patients with psychiatric illnesses may have a limited ability to recognize or communicate symptoms of physical danger, they must be closely monitored by knowledgeable medical and nursing staff. This case highlights the importance of preventing the accidental deaths of mentally retarded patients in nursing homes.
Lattice Boltzmann and Navier-Stokes Cartesian CFD Approaches for Airframe Noise Predictions
NASA Technical Reports Server (NTRS)
Barad, Michael F.; Kocheemoolayil, Joseph G.; Kiris, Cetin C.
2017-01-01
Lattice Boltzmann (LB) and compressible Navier-Stokes (NS) equations based computational fluid dynamics (CFD) approaches are compared for simulating airframe noise. Both LB and NS CFD approaches are implemented within the Launch Ascent and Vehicle Aerodynamics (LAVA) framework. Both schemes utilize the same underlying Cartesian structured mesh paradigm with provision for local adaptive grid refinement and sub-cycling in time. We choose a prototypical massively separated, wake-dominated flow ideally suited for Cartesian-grid based approaches in this study - The partially-dressed, cavity-closed nose landing gear (PDCC-NLG) noise problem from AIAA's Benchmark problems for Airframe Noise Computations (BANC) series of workshops. The relative accuracy and computational efficiency of the two approaches are systematically compared. Detailed comments are made on the potential held by LB to significantly reduce time-to-solution for a desired level of accuracy within the context of modeling airframes noise from first principles.
Plastic Faulting in Ice: Shear Localization under Elevated Pressure
NASA Astrophysics Data System (ADS)
Golding, N.; Durham, W. B.
2013-12-01
Ice exhibits, at least, two distinct kinds of shear faults when loaded triaxially under compression. Under moderate levels of confinement, brittle failure follows crack growth, crack coalescence and the development of a fault oriented about 30 degrees from the direction of maximum compression. The mechanism governing this mode of failure, termed frictional or Coulombic faulting, has previously been discussed for ice and rocks in connection with the comb-crack model. Under higher levels of confinement, where frictional sliding is suppressed by confining pressure, failure is characterized by sudden brittle-like loss in load bearing capacity and the development of a narrow shear band, comprised of recrystallized grains, oriented about 45 degrees from the direction of maximum compression, i.e. along the direction of maximum shear. This mode of failure, referred to here as plastic faulting, has previously been discussed for warm ice, T = 233 - 263 K, in connection with adiabatic shear heating and has been discussed for cold ice, T = 77 - 163 K, in connection with phase transformation. Here, new results are presented that examine the mechanical behavior and microstructural properties of plastic faulting in polycrystalline ice loaded at temperatures from T = 175 - 210 K and confining pressures up to P = 200 MPa. The results are reviewed in context of previous work and possible mechanisms to account for shear localization in ice under high pressure, including 1) adiabatic shear heating, 2) grain refinement and 3) phase transformation, are discussed. The present observations highlight the similarities in the behavior of plastic faulting under both warm and cold conditions and suggest adiabatic shear heating as a possible mechanism to account for shear instability and plastic faulting at temperatures ranging from T = 77 - 263 K.
Fontaine, Mathieu; Latarjet, Jacques; Payre, Jacqueline; Poupelin, Jean-Charles; Ravat, François
2017-03-01
The severe pain related to repeated burn dressing changes at bedside is often difficult to manage. However these dressings can be performed at bedside on spontaneously breathing non-intubated patients using powerful intravenous opioids with a quick onset and a short duration of action such as alfentanil. The purpose of this study is to demonstrate the efficacy and safety of the protocol which is used in our burn unit for pain control during burn dressing changes. Cohort study began after favorable opinion from local ethic committee has been collected. Patient's informed consent was collected. No fasting was required. Vital signs for patients were continuously monitored (non-invasive blood pressure, ECG monitoring, cutaneous oxygen saturation, respiratory rate) all over the process. Boluses of 500 (±250) mcg IV alfentanil were administered. A continuous infusion was added in case of insufficient analgesia. Adverse reactions were collected and pain intensity was measured throughout the dressing using a ten step verbal rating scale (VRS) ranging from 0 (no pain) to 10 (worst pain conceivable). 100 dressings (35 patients) were analyzed. Median age was 45 years and median burned area 10%. We observed 3 blood pressure drops, 5 oxygen desaturations (treated with stimulation without the necessity of ventilatory support) and one episode of nausea. Most of the patients (87%) were totally conscious during the dressing and 13% were awakened by verbal stimulation. Median total dose of alfentanil used was 2000μg for a median duration of 35min. Pain scores during the procedure were low or moderate (VRS mean=2.0 and maximal VRS=5). Median satisfaction collected 2h after the dressing was 10 on a ten step scale. Pain control with intravenous alfentanil alone is efficient and appears safe for most burn bedside repeated dressings in hospitalized patients. It achieves satisfactory analgesia during and after the procedure. It is now our standard analgesic method to provide repeated bedside dressings changes for burned patients. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Henriksson, Otto; Lundgren, J Peter; Kuklane, Kalev; Holmér, Ingvar; Bjornstig, Ulf
2009-01-01
In a cold, wet, or windy environment, cold exposure can be considerable for an injured or ill person. The subsequent autonomous stress response initially will increase circulatory and respiratory demands, and as body core temperature declines, the patient's condition might deteriorate. Therefore, the application of adequate insulation to reduce cold exposure and prevent body core cooling is an important part of prehospital primary care, but recommendations for what should be used in the field mostly depend on tradition and experience, not on scientific evidence. The objective of this study was to evaluate the thermal insulation properties in different wind conditions of 12 different blankets and rescue bags commonly used by prehospital rescue and ambulance services. The thermal manikin and the selected insulation ensembles were setup inside a climatic chamber in accordance to the modified European Standard for assessing requirements of sleeping bags. Fans were adjusted to provide low (< 0.5 m/s), moderate (2-3 m/s) and high (8-9 m/s) wind conditions. During steady state thermal transfer, the total resultant insulation value, Itr (m2 C/Wclo; where C = degrees Celcius, and W = watts), was calculated from ambient air temperature (C), manikin surface temperature (C), and heat flux (W/m2). In the low wind condition, thermal insulation of the evaluated ensembles correlated to thickness of the ensembles, ranging from 2.0 to 6.0 clo (1 clo = 0.155 m2 C/W), except for the reflective metallic foil blankets that had higher values than expected. In moderate and high wind conditions, thermal insulation was best preserved for ensembles that were windproof and resistant to the compressive effect of the wind, with insulation reductions down to about 60-80% of the original insulation capacity, whereas wind permeable and/or lighter materials were reduced down to about 30-50% of original insulation capacity. The evaluated insulation ensembles might all be used for prehospital protection against cold, either as single blankets or in multiple layer combinations, depending on ambient temperatures. However, with extended outdoor, on-scene durations, such as during prolonged extrications or in multiple casualty situations, the results of this study emphasize the importance of using a windproof and compression resistant outer ensemble to maintain adequate insulation capacity.
Ampawong, Sumate; Aramwit, Pornanong
2017-09-01
In this study, three kinds of antiseptics which were 0.05% chlorhexidine, 0.2% polyhexamethylene biguanide (PHMB), or 200 ppm silver nanoparticle was introduced to incorporate in the sericin-based scaffold to produce the antimicrobial dressing for the treatment of infected chronic wound. The effects of antiseptic incorporation on the stability, release of sericin, and short-term and long-term (6 months) antimicrobial activity of the sericin dressing against gram-negative and gram-positive bacteria were investigated. We showed that the incorporation of each antiseptic did not have significant effect on the internal morphology (pore size ~ 73-105 μm), elasticity (Young's modulus ~ 200-500 kPa), and the sericin release behavior of the sericin-based dressing. The release of sericin from the dressing was prolonged over 120 h and thereafter. Comparing among three antiseptics, 0.05% chlorhexidine incorporated in the sericin dressing showed the highest immediate and long-term (6 months) antimicrobial effect (largest inhibition zone) against most bacteria either gram-positive or gram-negative bacteria. The in vivo safety test following ISO10993 standard (Biological evaluation of medical devices - Part 6: Tests for local effects after implantation) confirmed that the sericin dressing incorporating 0.05% chlorhexidine did not irritate to tissue, comparing with the commercial material used generally in clinic (Allevyn®, Smith & Nephew). We suggested the sericin dressing incorporating 0.05% chlorhexidine for the treatment of infected chronic wound. Chlorhexidine would reduce the risk of infection while the sericin may promote wound healing.
Bikmoradi, Ali; Harorani, Mehdi; Roshanaei, Ghodratollah; Moradkhani, Shirin; Falahinia, Golam Hossein
2016-01-01
Pain is one of the common problems encountered by patients with burns, which increases after each dressing. This study aimed to investigate the effect of inhalation aromatherapy with damask rose essence on the pain of patients with burns that is caused after dressing. A randomized clinical trial was conducted on 50 patients with second- and third-degree burn wounds. The baseline pain of the patients was assessed 30 min before they entered into the dressing room on the first and second days of intervention. The patients in the experimental group inhaled five drops of damask rose essence 40% in distilled water, while those in the control group inhaled five drops of distilled water as placebo. The pain intensity was assessed using Visual Analogue Scale at 15 and 30 min after the patients exited from the dressing room. Data were analyzed by SPSS (version 18) using descriptive and inferential statistics. There was significant difference between the mean of pain intensity before and after intervention at 15 and 30 min after dressing (P < 0.001). Moreover, there was significant difference in reduction of pain intensity before and after aromatherapy in the experimental group (P < 0.05). Also, there was a significant reduction in severity of pain after dressing in the experimental group compared with the control group (P < 0.05). Inhalation aromatherapy with damask rose could be effective for relieving the pain caused after dressing in patients with burns. Therefore, it could be suggested as a complementary therapy in burn patients for pain relief.
Prophylactic Sacral Dressing for Pressure Ulcer Prevention in High-Risk Patients.
Byrne, Jaime; Nichols, Patricia; Sroczynski, Marzena; Stelmaski, Laurie; Stetzer, Molly; Line, Cynthia; Carlin, Kristen
2016-05-01
Patients in intensive care units are likely to have limited mobility owing to hemodynamic instability and activity orders for bed rest. Bed rest is indicated because of the severity of the disease process, which often involves intubation, sedation, paralysis, surgical procedures, poor nutrition, low flow states, and poor circulation. These patients are predisposed to the development and/or the progression of pressure ulcers not only because of their underlying diseases, but also because of limited mobility and deconditioned states of health. To assess whether treating high-risk patients with a prophylactic sacral dressing decreases the incidence of unit-acquired sacral pressure ulcers. An evidence-based tool for identifying patients at high risk for pressure ulcers was used in 3 intensive care units at an urban tertiary care hospital and academic medical center. Those patients deemed at high risk had a prophylactic sacral dressing applied. Incidence rates were collected and compared for the 7 months preceding use of the dressings and for 7 months during the trial period when the dressing was used. After the sacral dressing began being used, the number of unit-acquired sacral pressure ulcers decreased by 3.4 to 7.6 per 1000 patient days depending on the unit. A prophylactic sacral dressing may help prevent unit-acquired sacral pressure ulcers. Implementation of an involved care team with heightened awareness and increased education along with a prophylactic sacral dressing in patients deemed high risk for skin breakdown are all essential for success. ©2016 American Association of Critical-Care Nurses.
NASA Astrophysics Data System (ADS)
Patil, Sanjay S.; Bhalerao, Yogesh J.
2017-02-01
Grinding is metal cutting process used for mainly finishing the automobile components. The grinding wheel performance becomes dull by using it most of times. So it should be reshaping for consistent performance. It is necessary to remove dull grains of grinding wheel which is known as dressing process. The surface finish produced on the work piece is dependent on the dressing parameters in sub-sequent grinding operation. Multi-point diamond dresser has four important parameters such as the dressing cross feed rate, dressing depth of cut, width of the diamond dresser and drag angle of the dresser. The range of cross feed rate level is from 80-100 mm/min, depth of cut varies from 10 - 30 micron, width of diamond dresser is from 0.8 - 1.10mm and drag angle is from 40o - 500, The relative closeness to ideal levels of dressing parameters are found for surface finish produced on the En-31 work piece during sub-sequent grinding operation by using Technique of Order Preference by Similarity to Ideal Solution (TOPSIS).In the present work, closeness to ideal solution i.e. levels of dressing parameters are found for Computer Numerical Control (CNC) cylindrical angular grinding machine. After the TOPSIS technique, it is found that the value of Level I is 0.9738 which gives better surface finish on the En-31 work piece in sub-sequent grinding operation which helps the user to select the correct levels (combinations) of dressing parameters.
Medical workers' cognition of using 50% nitrous oxide in children with burns: a qualitative study.
Wang, Hai-Xia; Li, Yu-Xiang; Zhou, Ru-Zhen; Zhao, Ji-Jun
2015-09-01
Pain caused by dressing among children with burns is an issue worth discussing. Medical workers' understanding of pain during dressing in children with burns is correlated with the quality of pain management. Effective pain management is significant to improve anxiety and reduce pain and psychological distress during dressing for children with burns. We aimed to investigate medical workers' understanding of current pain management during dressing among children with burns and their attitudes toward the application of 50% nitrous oxide in pain management. Interviews were conducted with seven doctors and nurses from a burn center in East China. Data were collected by in-depth interviews and qualitative description after full transcription of each interview. Three themes were identified: (1) Medical workers felt sympathy for children with burns and believed that a gap existed between the current and expected situation in pain management. In addition, the prescription of analgesics during dressing for children with burns was not favored. (2) Given the fact that 50% nitrous oxide is effective in pain management for adult patients with burns, medical workers tended to apply it to children with burns during dressing after being provided the literature on the use of 50% nitrous oxide in children. (3) Guidelines for the application of 50% nitrous oxide during dressing for children with burns require further modification. Medical workers deemed the pain management for children with burns unsatisfactory, and they supported the application of 50% nitrous oxide during dressing for children with burns. Meanwhile, they hoped that administrators would also support it. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Fontenot, Krystal R; Edwards, J Vincent; Haldane, David; Pircher, Nicole; Liebner, Falk; Condon, Brian D; Qureshi, Huzaifah; Yager, Dorne
2017-11-01
Interfacing nanocellulosic-based biosensors with chronic wound dressings for protease point of care diagnostics combines functional material properties of high specific surface area, appropriate surface charge, and hydrophilicity with biocompatibility to the wound environment. Combining a protease sensor with a dressing is consistent with the concept of an intelligent dressing, which has been a goal of wound-dressing design for more than a quarter century. We present here biosensors with a nanocellulosic transducer surface (nanocrystals, nanocellulose composites, and nanocellulosic aerogels) immobilized with a fluorescent elastase tripeptide or tetrapeptide biomolecule, which has selectivity and affinity for human neutrophil elastase present in chronic wound fluid. The specific surface area of the materials correlates with a greater loading of the elastase peptide substrate. Nitrogen adsorption and mercury intrusion studies revealed gas permeable systems with different porosities (28-98%) and pore sizes (2-50 nm, 210 µm) respectively, which influence water vapor transmission rates. A correlation between zeta potential values and the degree of protease sequestration imply that the greater the negative surface charge of the nanomaterials, the greater the sequestration of positively charged neutrophil proteases. The biosensors gave detection sensitivities of 0.015-0.13 units/ml, which are at detectable human neutrophil elastase levels present in chronic wound fluid. Thus, the physical and interactive biochemical properties of the nano-based biosensors are suitable for interfacing with protease sequestrant prototype wound dressings. A discussion of the relevance of protease sensors and cellulose nanomaterials to current chronic wound dressing design and technology is included.
Tan, Xueli; Yowler, Charles J; Super, Dennis M; Fratianne, Richard B
2010-01-01
The purpose of this study was to explore the efficacy of two music therapy protocols on pain, anxiety, and muscle tension levels during dressing changes in burn patients. Twenty-nine inpatients participated in this prospective, crossover randomized controlled trial. On two consecutive days, patients were randomized to receive music therapy services either on the first or second day of the study. On control days, they received no music. On music days, patients practiced music-based imagery (MBI), a form of music-assisted relaxation with patient-specific mental imagery before and after dressing changes. Also, on music days during dressing changes, the patients engaged in music alternate engagement (MAE), which consisted of active participation in music making. The dependent variables were the patients' subjective ratings of their pain and anxiety levels and the research nurse's objective ratings of their muscle tension levels. Two sets of data were collected before, three sets during, and another two sets after dressing changes. The results showed significant decrease in pain levels before (P < .025), during (P < .05), and after (P < .025) dressing changes on days the patients received music therapy in contrast to control days. Music therapy was also associated with a decrease in anxiety and muscle tension levels during the dressing changes (P < .05) followed by a reduction in muscle tension levels after dressing changes (P < .025). Music therapy significantly decreases the acute procedural pain, anxiety, and muscle tension levels associated with daily burn care.
#TheDress: Categorical perception of an ambiguous color image.
Lafer-Sousa, Rosa; Conway, Bevil R
2017-10-01
We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region.
What #theDress reveals about the role of illumination priors in color perception and color constancy
Aston, Stacey; Hurlbert, Anya
2018-01-01
The disagreement between people who named #theDress (the Internet phenomenon of 2015) “blue and black” versus “white and gold” is thought to be caused by individual differences in color constancy. It is hypothesized that observers infer different incident illuminations, relying on illumination “priors” to overcome the ambiguity of the image. Different experiences may drive the formation of different illumination priors, and these may be indicated by differences in chronotype. We assess this hypothesis, asking whether matches to perceived illumination in the image and/or perceived dress colors relate to scores on the morningness-eveningness questionnaire (a measure of chronotype). We find moderate correlations between chronotype and illumination matches (morning types giving bluer illumination matches than evening types) and chronotype and dress body matches, but these are significant only at the 10% level. Further, although inferred illumination chromaticity in the image explains variation in the color matches to the dress (confirming the color constancy hypothesis), color constancy thresholds obtained using an established illumination discrimination task are not related to dress color perception. We also find achromatic settings depend on luminance, suggesting that subjective white point differences may explain the variation in dress color perception only if settings are made at individually tailored luminance levels. The results of such achromatic settings are inconsistent with their assumed correspondence to perceived illumination. Finally, our results suggest that perception and naming are disconnected, with observers reporting different color names for the dress photograph and their isolated color matches, the latter best capturing the variation in the matches. PMID:28793353
#TheDress: Categorical perception of an ambiguous color image
Lafer-Sousa, Rosa; Conway, Bevil R.
2017-01-01
We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region. PMID:29090319
Black, Jonathan S; Drake, David B
2015-01-01
The lipid base of silver sulfadiazine (SSD) makes removal of the product painful for the patient and difficult for the physician to accurately assess particularly in partial-thickness burn injuries. As an alternative, a water-soluble antimicrobial gel is used at the University of Virginia. We present a prospective, randomized comparison of these two therapies using pain with dressing changes and time to perform dressing changes as our primary endpoints. Adult inpatients with partial-thickness burn wounds were randomized to begin therapy with either SSD cream or the water-soluble burn wound gel (BWG), and then therapies were alternated daily. Pain assessments, time to complete dressing care, total narcotic medication administered, and the number of personnel required for dressing changes were recorded. Eight patients were enrolled resulting in 13 pairs (26 points) of data comparison between the two therapies. Four of the eight enrolled patients (50%) refused to continue receiving SSD because of pain associated with dressing changes and voluntarily withdrew from the study. The amount of time to perform dressing changes was an average of 79 nurse-minutes longer for SSD. A 6.08 greater morphine equivalent was delivered to those having BWG removed.A water-soluble polyantimicrobial gel was superior to SSD in the parameters measured as exhibited by our patient dropout rate and differential time to perform dressing care. Limiting the time to perform dressing care will reduce the cumulative pain experience, improve patient satisfaction, and reduce the resources to deliver care.
Fashion as Argument: Nineteenth-Century Dress Reform.
ERIC Educational Resources Information Center
Torrens, Kathleen M.
1999-01-01
Examines the place of the body in the dress-reform movement, a social movement that focused on fashion as a vehicle for achieving social and political equality. Discusses how fashion became one arena in which definitions of gender were contested. Suggests the dress-reform movement's failure in redefining femininity indicates the depth of…
ERIC Educational Resources Information Center
Chatelain, Amber M.
2015-01-01
This study sought to discover student perceptions of academics' dress and gender and their impact on perceived instructor approachability and likeability. Three categories of dress were examined: casual, business casual and professional. The results of this study suggest students at career-arts institutions perceive female teachers as less…
ERIC Educational Resources Information Center
Freeburg, Beth Winfrey; Workman, Jane E.
2010-01-01
The purpose of this study was to explore teacher dress in United States schools as presented in the newspaper. Twenty-nine articles were examined to answer three questions. Results revealed: (a) the newspaper provided four contexts for processing information about teacher dress--roles, control, impression management, and educational learning…
Dress-Related Responses to the Columbine Shootings: Other-Imposed and Self-Designed.
ERIC Educational Resources Information Center
Ogle, Jennifer Paff; Eckman, Molly
2002-01-01
An inductive content analysis approach was used to examine 155 dress-related newspaper articles following the Columbine High School shootings in 1999. Analysis revealed two dress-related responses: (1) other-imposed regulation to protect students and deter them from expressing hatred and (2) self-designed acts of resistance for grieving. (Contains…
ERIC Educational Resources Information Center
Morris, Tracy L.; And Others
1996-01-01
Finds that more formal dress (business suits, dress shoes) was associated with increased ratings of teaching assistants' competence, particularly for female students rating female instructors. Shows, however, that contrary to common assumptions, the most positive influences of instructor dress were found in the highly casual condition (faded…
Effect of Andrographis paniculata leaf extract on wound healing in rats.
Al-Bayaty, Fouad Hussain; Abdulla, Mahmood Ameen; Abu Hassan, Mohamed Ibrahim; Ali, Hapipah Mohd
2012-01-01
This work was carried out to study the effect of topical application of Andrographis paniculata on the rate of wound enclosure and its histological features. A wound was created in four groups of rat in posterior neck region. Blank placebo was applied topically to the wounds of Group 1. Groups 2 and 3 were dressed with placebo containing 5% and 10% extracts of A. paniculata, respectively. Intrasite gel was applied topically to the wounds of Group 4. Macroscopical examination revealed that the rate of wound healing was significantly accelerated in the wound dressed with A. paniculata extract compared to the blank placebo. The wounds dressed with 10% extract or Intrasite gel healed earlier compared to the wounds dressed with placebo containing 5% A. paniculata extract. Histologically, wounds dressed with A. paniculata extracts showed markedly less scar width and contained large amounts of fibroblast proliferation. More collagen and less angiogenesis with absence of inflammatory cells were seen for wounds dressed with 10% A. paniculata compared to the blank placebo. Conclusion, A. paniculata extracts significantly enhanced rate of wound healing in rats.
An in vitro test of the efficacy of an anti-biofilm wound dressing.
Said, Jawal; Walker, Michael; Parsons, David; Stapleton, Paul; Beezer, Anthony E; Gaisford, Simon
2014-10-20
Broad-spectrum antimicrobial agents, such as silver, are increasingly being formulated into medicated wound dressings in order to control colonization of wounds by opportunistic pathogens. Medicated wound dressings have been shown in-vitro to be effective against planktonic cultures, but in-vivo bacteria are likely to be present in biofilms, which makes their control and eradication more challenging. Recently, a functional wound dressing (AQUACEL(®) Ag+ Extra™ (AAg + E)) has been developed that in addition to silver contains two agents (ethylenediaminetetraacetic acid (EDTA) and benzethonium chloride (BC)) designed to disrupt biofilms. Here, the efficacy of AAg + E is demonstrated using a biofilm model developed in an isothermal microcalorimeter. The biofilm was seen to remain viable in the presence of unmedicated dressing, silver-containing dressing or silver nitrate solution. In the presence of AAg + E, however, the biofilm was eradicated. Control experiments showed that neither EDTA nor BC alone had a bactericidal effect, which means it is the synergistic action of EDTA and BC disrupting the biofilm with silver being bactericidal that leads to the product's efficacy. Copyright © 2014 Elsevier B.V. All rights reserved.
Mitchell, Michael S; Koen, Clifford M; Moore, Thomas W
2013-01-01
As more and more individuals choose to express themselves and their religious beliefs with headwear, jewelry, dress, tattoos, and body piercings and push the envelope on what is deemed appropriate in the workplace, employers have an increased need for creation and enforcement of reasonable dress codes and appearance policies. As with any employment policy or practice, an appearance policy must be implemented and enforced without regard to an individual's race, color, sex, national origin, religion, disability, age, or any other protected status. A policy governing dress and appearance based on the business needs of an employer that is applied fairly and consistently and does not have a disproportionate effect on any protected class will generally be upheld if challenged in court. By examining some of the more common legal challenges to dress codes and how courts have resolved the disputes, health care managers can avoid many potential problems. This article addresses the issue of religious discrimination focusing on dress and appearance and some of the court cases that provide guidance for employers.
Dispersive detection of radio-frequency-dressed states
NASA Astrophysics Data System (ADS)
Jammi, Sindhu; Pyragius, Tadas; Bason, Mark G.; Florez, Hans Marin; Fernholz, Thomas
2018-04-01
We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.
The effect of semirigid dressings on below-knee amputations.
MacLean, N; Fick, G H
1994-07-01
The effect of using semirigid dressings (SRDs) on the residual limb of individuals who have had below-knee amputations as a consequence of peripheral vascular disease was investigated, with the primary question being: Does the time to readiness for prosthetic fitting for patients treated with the SRDs differ from that of patients treated with soft dressings? Forty patients entered the study and were alternately assigned to one of two groups. Nineteen patients were assigned to the SRD group, and 21 patients were assigned to the soft dressing group. The time from surgery to readiness for prosthetic fitting was recorded for each patient. Kaplan-Meier survival curves were generated for each group, and the results were analyzed with the log-rank test. There was a difference between the two curves, and an examination of the curves suggests that the expected time to readiness for prosthetic fitting for patients treated with the SRDs would be less than half that of patients treated with soft dressings. The results suggest that a patient may be ready for prosthetic fitting sooner if treated with SRDs instead of soft dressings.
Alternate hot and cold application in the management of heel pain: A pilot study.
Arankalle, Dhananjay; Wardle, Jon; Nair, Pradeep M K
2016-12-01
Despite a long-standing tradition of naturopathic physical therapy and hydrotherapy use in the treatment of musculoskeletal conditions, neither naturopathy, nor specific aspects of hydrotherapy have been tested for efficacy in the treatment of heel pain. Patients (n=20) were assigned to standard naturopathic physiotherapy care (NPC) with two adjuvant therapy groups: a control group (therapeutic ultrasound, n=10), or alternating compresses (n=10). Pain scores were measured before and after treatment using Visual Analog Scale (VAS) and foot functionality was measured using the Foot Function Index (FFI). FFI reduced from 46.97 to 31.98 (p=0.005) among normal protocol patients and from 49.72 to 21.35 (p=<0.001) among patients receiving the alternating compress protocol. Average VAS pain intensity in the seven days of treatment decreased from 3.53 to 2.53cm (p=<0.001) among patients receiving NPC and from 4.09 to 2.61cm (p=<0.001) amongst those receiving NPC plus alternating compresses. There was no significant difference in pain score reduction between the two groups (p=0.206), but patients with alternating compresses as part of their treatment had significant improvements in foot functionality (p=0.007). Naturopathic physical therapy significantly improves foot functionality and pain scores in heel pain. Additionally, alternating compresses improve foot functionality scores. Copyright © 2016 Elsevier Ltd. All rights reserved.
Influence of Non-Maxwellian Particles on Dust Acoustic Waves in a Dusty Magnetized Plasma
NASA Astrophysics Data System (ADS)
M. Nouri, Kadijani; Zareamoghaddam, H.
2013-11-01
In this paper an investigation into dust acoustic solitary waves (DASWs) in the presence of superthermal electrons and ions in a magnetized plasma with cold dust grains and trapped electrons is discussed. The dynamic of both electrons and ions is simulated by the generalized Lorentzian (κ) distribution function (DF). The dust grains are cold and their dynamics are studied by hydrodynamic equations. The basic set of fluid equations is reduced to modified Korteweg-de Vries (mKdV) equation using Reductive Perturbation Theory (RPT). Two types of solitary waves, fast and slow dust acoustic soliton (DAS) exist in this plasma. Calculations reveal that compressive solitary structures are possibly propagated in the plasma where dust grains are negatively (or positively) charged. The properties of DASs are also investigated numerically.
Günal, Özgür; Tuncel, Umut; Turan, Aydin; Barut, Sener; Kostakoglu, Naci
2015-10-01
The aim of this retrospective study was to evaluate the efficacy of vacuum-assisted closure (VAC) and GranuFoam Silver® dressing (KCI, San Antonio, TX) compared with conventional GranuFoam® dressing in the management of diabetic foot ulcers. Twenty-one consecutive patients treated with conventional or silver-coated foam dressing were reviewed retrospectively. The wound duration was 6 mo. Group 1 (n=10) received conventional foam dressing (GranuFoam) and group 2 (n=11) received silver-coated foam dressing (GranuFoam Silver). The wound surface area, duration of treatment, bacteriology, and recurrence were compared between the groups. The mean age of the patients was 61.70±10.52 y in group 1 and 67.27±11.28 y in group 2. In group 1, the average surface area of the wounds was 45.30±46.96 cm2 and 18.40±23.48 cm2 in the pre-treatment and post-treatment periods, respectively. There was a statistically significant difference between two measurements (p=0.005). Average duration of the treatment was 25.50±27.13 d in this group. In group 2, average surface area of the wounds in the pre-treatment and post-treatment periods were 41.55±36.03 cm2 and 7.64±3.91 cm2, respectively. There was a statistically significant difference between two measurements (p=0.003). Average duration of the treatment was 10.09±3.51 d in this group. The patients treated with silver-impregnated polyurethane foam dressing had reduced recurrence (2 vs. 7 wounds, p=0.030) and increased number of the culture-negative cases at the end of the treatment. With the results of the study, it was concluded that VAC GranuFoam silver dressing can be superior to conventional GranuFoam dressing in reducing the recurrence rate of infected diabetic foot ulcers.
Heyneman, A; Hoeksema, H; Vandekerckhove, D; Pirayesh, A; Monstrey, S
2016-11-01
For more than 40 years, silver sulphadiazine 1% (SSD) is considered as standard therapy for the conservative treatment of burn wounds. However, in the last 10 years, substantial disadvantages of SSD have been reported in the literature and probably as a result of this, several new dressings for burn wounds have been developed and put on the market. The objective of this systematic review is to evaluate the available evidence on SSD in the conservative treatment of burns, specifically in comparison with the newer burn dressings that are increasingly being used nowadays. A search filter was composed to select randomized controlled trials (RCTs) from the MEDLINE database. Only RCTs studying the effect of conservative treatment on burns were selected. At least one of the two comparative groups was treated with SSD. Each included article was analysed and relevant data (baseline parameters, interventions, outcomes and methodological parameters) were registered using Microsoft Office Excel 2007. Many dressings showed superior healing properties compared to SSD, but no dressing was able to show a clear benefit over SSD regarding infection. The number of dressing changes, pain and patient's satisfaction are more favourable in the newer dressings, especially with solid and biological dressings. The results of this systematic review clearly demonstrate that a faster wound healing is obtained with the newly developed burn dressings. Additionally, these new dressings tend to be more comfortable for the patients and easier to use for care givers. The minor differences in antibacterial activity between SSD and the new products did not seem to have any influence on the rate of wound healing. Since rapid wound closure is essential to obtain an optimal functional and aesthetic outcome, it can be concluded from the results of this systemic review that the standard use of SSD in the conservative treatment of burn wounds can no longer be supported. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Dynamical Casimir-Polder force on a partially dressed atom near a conducting wall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Messina, Riccardo; Vasile, Ruggero; Passante, Roberto
2010-12-15
We study the time evolution of the Casimir-Polder force acting on a neutral atom in front of a perfectly conducting plate, when the system starts its unitary evolution from a partially dressed state. We solve the Heisenberg equations for both atomic and field quantum operators, exploiting a series expansion with respect to the electric charge and an iterative technique. After discussing the behavior of the time-dependent force on an initially partially dressed atom, we analyze a possible experimental scheme to prepare the partially dressed state and the observability of this new dynamical effect.
Multiple deformation mechanisms of Ti-22.4Nb-0.73Ta-2.0Zr-1.34O alloy
NASA Astrophysics Data System (ADS)
Yang, Y.; Li, G. P.; Cheng, G. M.; Li, Y. L.; Yang, K.
2009-02-01
Ti-22.4Nb-0.73Ta-2.0Zr-1.34O (at. %) alloy after cold compression to ˜5.2% strain was investigated. The alloy exhibited multiple plastic deformation mechanisms, including the stress-induced α″ martensitic (SIM α″) and ω phase transformations, 1/2⟨111⟩ dislocations slipping on the {112}β planes as well as {332}⟨113⟩β and {112}⟨111⟩β twinning, which have not previously been reported to coexist in a titanium alloy. It was also found that β phase with the {200} planes vertical to the compression direction was almost completely consumed away by a β →SIM α″ transformation, and a (100) texture of SIM α″ formed.
Hasatsri, Sukhontha; Angspatt, Apichai
2015-01-01
We developed the novel silk fibroin-based bilayered wound dressing for the treatment of partial thickness wounds. And it showed relevant characteristics and accelerated the healing of full-thickness wounds in a rat model. This study is the clinical evaluation of the bilayered wound dressing to confirm its safety and efficacy for the treatment of split-thickness skin donor sites. The safety test was performed using a patch model and no evidence of marked and severe cutaneous reactions was found. The efficacy test of the bilayered wound dressing was conducted on 23 patients with 30 split-thickness skin graft donor sites to evaluate healing time, pain score, skin barrier function, and systemic reaction in comparison to Bactigras. We found that the healing time of donor site wounds treated with the bilayered wound dressing (11 ± 6 days) was significantly faster than those treated with Bactigras (14 ± 6 days) (p = 10−6). The wound sites treated with the bilayered wound dressing showed significantly less pain and more rapid skin functional barrier recovery than those treated with Bactigras (p = 10−5). Therefore, these results confirmed the clinical safety and efficacy of the bilayered wound dressing for the treatment of split-thickness skin graft donor sites. PMID:26221170
Economic impact of Tegaderm chlorhexidine gluconate (CHG) dressing in critically ill patients.
Thokala, Praveen; Arrowsmith, Martin; Poku, Edith; Martyn-St James, Marissa; Anderson, Jeff; Foster, Steve; Elliott, Tom; Whitehouse, Tony
2016-09-01
To estimate the economic impact of a Tegaderm TM chlorhexidine gluconate (CHG) gel dressing compared with a standard intravenous (i.v.) dressing (defined as non-antimicrobial transparent film dressing), used for insertion site care of short-term central venous and arterial catheters (intravascular catheters) in adult critical care patients using a cost-consequence model populated with data from published sources. A decision analytical cost-consequence model was developed which assigned each patient with an indwelling intravascular catheter and a standard dressing, a baseline risk of associated dermatitis, local infection at the catheter insertion site and catheter-related bloodstream infections (CRBSI), estimated from published secondary sources. The risks of these events for patients with a Tegaderm CHG were estimated by applying the effectiveness parameters from the clinical review to the baseline risks. Costs were accrued through costs of intervention (i.e. Tegaderm CHG or standard intravenous dressing) and hospital treatment costs depended on whether the patients had local dermatitis, local infection or CRBSI. Total costs were estimated as mean values of 10,000 probabilistic sensitivity analysis (PSA) runs. Tegaderm CHG resulted in an average cost-saving of £77 per patient in an intensive care unit. Tegaderm CHG also has a 98.5% probability of being cost-saving compared to standard i.v. dressings. The analyses suggest that Tegaderm CHG is a cost-saving strategy to reduce CRBSI and the results were robust to sensitivity analyses.
Silver deposition and tissue staining associated with wound dressings containing silver.
Walker, Michael; Cochrane, Christine A; Bowler, Philip G; Parsons, David; Bradshaw, Peter
2006-01-01
Argyria is the general term used to denote a clinical condition in which excessive administration and deposition of silver causes a permanent irreversible gray-blue discoloration of the skin or mucous membranes. The amount of discoloration usually depends on the route of silver delivery (ie, oral or topical administration) along with the body's ability to absorb and excrete the administered silver compound. Argyria is accepted as a rare dermatosis but once silver particles are deposited, they remain immobile and may accumulate during the aging process. Topical application of silver salts (eg, silver nitrate solution) may lead to transient skin staining. To investigate their potential to cause skin staining, two silver-containing dressings (Hydrofiber and nanocrystalline) were applied to human skin samples taken from electively amputated lower limbs. The potential for skin discoloration was assayed using atomic absorption spectroscopy. When the dressings were hydrated with water, a significantly higher amount of silver was released from the nanocrystalline dressing compared to the Hydrofiber dressing (P <0.005), which resulted in approximately 30 times more silver deposition. In contrast, when saline was used as the hydration medium, the release rates were low for both dressings and not significantly different (silver deposition was minimal). Controlling the amount of silver released from silver-containing dressings should help reduce excessive deposition of silver into wound tissue and minimize skin staining.
Hämmerle, Gilbert; Strohal, Robert
2016-04-01
The aim of this study was to determine the efficacy, safety and cost-effectiveness of an octenidine-based wound gel in the treatment of chronic venous leg ulcers. For this purpose, 49 wounds were treated with either modern wound-phase-adapted dressings alone (treatment arm 1; n = 17), octenidine wound gel plus modern wound-phase-adapted dressings (treatment arm 2; n = 17) or octenidine wound gel alone (treatment arm 3; n = 15). During the study period of 42 days with dressing changes every 3-5 days, wound healing characteristics and treatment costs of different dressings were analysed. Wound size reduction was significantly better (P = 0·028) in both octenidine wound gel treatment arms compared to modern dressings alone with total reductions of 14·6%, 64·1% and 96·2% in treatment arms 1-3. Early wound healing was merely observed under octenidine wound gel treatment (n = 9), whereby lowest treatment costs were generated by octenidine wound gel alone (€20·34/dressing change). As a result, the octenidine wound gel is cost-effective and well suitable for the treatment of chronic venous leg ulcers, considering both safety and promotion of wound healing. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Anjum, Sadiya; Gupta, Amlan; Sharma, Deepika; Gautam, Deepti; Bhan, Surya; Sharma, Anupama; Kapil, Arti; Gupta, Bhuvanesh
2016-07-01
This study is aimed at the development of a composite material for wound dressing containing nanosilver nanohydrogels (nSnH) along with Aloe vera and curcumin that promote antimicrobial nature, wound healing and infection control. Nanosliver nanohydrogels were synthesized by nanoemulsion polymerization of methacrylic acid (MAA) followed by subsequent crosslinking and silver reduction under irradiation. Both the polymerization and irradiation time had significant influence on the nanoparticle shape, size and its formation. Polyvinyl alcohol/polyethylene oxide/carboxymethyl cellulose matrix was used as gel system to blend with nSnH, A. vera, curcumin and coat it on the hydrolysed PET fabric to develop antimicrobial dressings. The cumulative release of silver from the dressing was found to be ~42% of the total loading after 48h. The antimicrobial activity of the dressings was studied against both Staphylococcus aureus and Escherichia coli. In vivo wound healing studies were carried out over a period of 16d on full-thickness skin wounds created on Swiss albino mice. Fast healing was observed in Gel/nSnH/Aloe treated wounds with minimum scarring, as compared to other groups. The histological studies showed A. vera based dressings to be the most optimum one. These results suggest that nSnH along with A. vera based dressing material could be promising candidates for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.
Spatial filtering, color constancy, and the color-changing dress.
Dixon, Erica L; Shapiro, Arthur G
2017-03-01
The color-changing dress is a 2015 Internet phenomenon in which the colors in a picture of a dress are reported as blue-black by some observers and white-gold by others. The standard explanation is that observers make different inferences about the lighting (is the dress in shadow or bright yellow light?); based on these inferences, observers make a best guess about the reflectance of the dress. The assumption underlying this explanation is that reflectance is the key to color constancy because reflectance alone remains invariant under changes in lighting conditions. Here, we demonstrate an alternative type of invariance across illumination conditions: An object that appears to vary in color under blue, white, or yellow illumination does not change color in the high spatial frequency region. A first approximation to color constancy can therefore be accomplished by a high-pass filter that retains enough low spatial frequency content so as to not to completely desaturate the object. We demonstrate the implications of this idea on the Rubik's cube illusion; on a shirt placed under white, yellow, and blue illuminants; and on spatially filtered images of the dress. We hypothesize that observer perceptions of the dress's color vary because of individual differences in how the visual system extracts high and low spatial frequency color content from the environment, and we demonstrate cross-group differences in average sensitivity to low spatial frequency patterns.
Gharibi, Reza; Yeganeh, Hamid; Rezapour-Lactoee, Alireza; Hassan, Zuhair M
2015-11-04
A series of novel polyurethane/siloxane-based wound dressing membranes was prepared through sol-gel reaction of methoxysilane end-functionalized urethane prepolymers composed of castor oil and ricinoleic methyl ester as well as methoxysilane functional aniline tetramer (AT) moieties. The samples were fully characterized and their physicochemical, mechanical, electrical, and biological properties were assayed. The biological activity of these dressings against fibroblast cells and couple of microbes was also studied. It was revealed that samples that displayed electroactivity by introduction of AT moieties showed a broad range of antimicrobial activity toward different microorganisms, promising antioxidant (radical scavenging) efficiency and significant activity for stimulation of fibroblast cell growth and proliferation. Meanwhile, these samples showed appropriate tensile strength and ability for maintaining a moist environment over a wound by controlled equilibrium water absorption and water vapor transmission rate. The selected electroactive dressing was subjected to an in vivo assay using a rat animal model and the wound healing process was monitored and compared with analogous dressing without AT moieties. The recorded results showed that the electroactive dressings induced an increase in the rate of wound contraction, promoted collagen deposition, and encouraged vascularization in the wounded area. On the basis of the results of in vitro and in vivo assays, the positive influence of designed dressings for accelerated healing of a wound model was confirmed.
Modeling Strongly Correlated Fermi Systems Using Ultra-Cold Atoms
2008-06-28
the two-dimensional Hubbard model on a square lattice ( a model which is purported to describe the high-temperature superconducting cuprates...beams and (2) stroboscopically alternating the beams very rapidly (~100 kHz) such that the beams were never on simultaneously ( the atoms experience a ...gases relies on (1) using a large-volume, magnetic trap to compress the atomic gas to a volume that can be captured by an optical trap
NASA Astrophysics Data System (ADS)
Veerasamy, M.; Srinivasan, K.; Prakash, Raghu V.
2010-10-01
The crash behavior of Cold Rolled Mild Steel (CRMS) closed form thin section was studied by conducting compressive tests at loading velocities of 5 mm/min and 1000 mm/min. The numerical simulations were conducted for the same experimental conditions to understand the deformation shape, peak forces and energy absorption capacity of sections at different impact velocities. The simulation results correlated well with the experimental results.
Rodriguez, Maria I; Jensen, Jeffrey T; Gregory, Kenton; Bullard, Mary; Longo, Paul; Heidel, Jerry; Edelman, Alison
2017-06-13
Although uterine tamponade is an effective treatment for postpartum hemorrhage (PPH), current methods have key limitations in their use, particularly in low resource settings. The XStat™ Mini Sponge Dressing (MSD) is approved for the management of non-compressible wounds in the battlefield/trauma setting. The MSD applies highly compressed medical sponges capable of stopping high-flow arterial bleeding within seconds. The objective of our study was to adopt the MSD for use in managing PPH. We performed desktop testing using a uterine model with pressure sensors to compare key design elements of the obstetrical prototype MSD (fundal pressure achieved, reduction in fluid loss, time to deploy, and time to remove) with alternativetechniques (uterine packing, balloon tamponade). To evaluate safety, we delivered the fetus of pregnant ewes by cesarean section and used the prototype to deliver the MSD into one uterine horn, and closed the hysterotomy. We followed the clinical recovery of animals (n = 3) over 24 h, and then removed the reproductive tract for histologic evaluation. To evaluate late effects, we surgically removed the MSDs after 24 h, and followed the clinical recovery of animals (n = 6) for an additional seven days before tissue removal. The obstetrical prototype has a long tapered delivery system designed to be deployed during vaginal examination, and administers three times the volume of the approved MSD trauma bandage. The MSD are deployed within a mesh bag to facilitate removal by vaginaltraction. On desktop testing, the MSD resulted in the highest average fundal pressure (113 mmHg), followed by the MSD bag device (85.8 mmHg), gauze packing (15.5 mmHg), and the uterine balloon (8.2 mmHg). The MSD bag test group achieved the largest fluid flow reduction of -74%, followed by gauze packing (-55%), MSD (-35%), and uterine balloon (-19%). Animal testing demonstrated good uterine fill with no evidence of adverse clinical recovery, uterine trauma or infection at 24 h, or up to 7 days following device removal. We adapted a highly effective trauma dressing and applicator for use in the treatment of severe PPH. Preliminary desktop and animal testing provide a basis for initial clinical trials in women.
Donovan, Michelle L; Muller, Michael J; Simpson, Claire; Rudd, Michael; Paratz, Jennifer
2016-04-26
Pressure garment therapy (PGT) is well accepted and commonly used by clinicians in the treatment of burns scars and grafts. The medium to high pressures (24-40 mmHg) in these garments can support scar minimisation, and evidence is well documented for this particular application. However, PGT specifically for burn donor sites, of which a sequela is also scarring, is not well documented. This study protocol investigates the impact of a low pressure (4-6 mmHg) interim garment on donor site healing and scarring. With a primary purpose of holding donor dressings in place, the application of the interim pressure garment (IPG) appears to have been twofold. IPGs for donor sites have involved inconsistent application with a focus on securing wound dressing rather than scar management. However, anecdotal and observational evidence suggests that IPGs also make a difference to some patient's scar outcomes for donor sites. This study protocol outlines a randomised controlled trial designed to test the effectiveness of this treatment on reducing scarring to burn donor sites. This study is a single-centre, single (assessor)-blinded, randomised control trial in patients with burns donor sites to their thighs. Patients will be randomly allocated to a control group (with no compression to donor sites) or to an experimental group (with compression to donor sites) as the comparative treatment. Groups will be compared at baseline regarding the important prognostic indicators: donor site location, depth, size, age, and time since graft (5 days). The IPG treatment will be administered post-operatively (on day 5). Follow-up assessments and garment replacement will be undertaken fortnightly for a period of 2 months. This study focuses on a unique area of burns scar management using a low-pressure tubular support garment for the reduction of donor site scars. Such therapy specifically for donor scar management is poorly represented in the literature. This study was designed to test a potentially cost-effective scar prevention for patients with donor sites to the thigh. No known studies of this nature have been carried out to date, and there is a need for rigorous clinical evidence for low-pressure support garments for donor site scar minimisation. Australian New Zealand Clinical Trials Registry identifier ACTRN12610000127000 . Registered 8 Mar 2010.
Civil Behavior, Safe-School Planning, and Dress Codes
ERIC Educational Resources Information Center
Studak, Cathryn M.; Workman, Jane E.
2007-01-01
This research examined news reports in order to identify incidents that precipitated dress code revisions. News reports were examined within the framework of rules for civil behavior. Using key words "school dress codes" and "violence," LEXIS/NEXIS was used to access 104 articles from 44 U.S. newspapers from December 3, 2004 to December 2, 2005.…
Cross Dressing and Gender Dysphoria in People with Learning Disabilities: A Descriptive Study
ERIC Educational Resources Information Center
Parkes, Georgina; Hall, Ian; Wilson, Daniel
2009-01-01
We aimed to determine the characteristics of people with learning disability who cross-dress or who have gender dysphoria. Using a retrospective review of anonymised data from clinical records about people referred to a specialist service. All 13 participants cross-dressed and 12 were biological males. Only one person was in a core transsexual…
Rural School District Dress Code Implementation: Perceptions of Stakeholders after First Year
ERIC Educational Resources Information Center
Wright, Krystal M.
2012-01-01
Schools are continuously searching for solutions to solve truancy, academic, behavioral, safety, and climate issues. One of the latest trends in education is requiring students to adhere to dress codes as a solution to these issues. Dress codes can range from slightly restrictive clothing to the requiring of a uniform. Many school district…
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
Effect of Most-to-Least Prompting Procedure on Dressing Skill of Students with Autism
ERIC Educational Resources Information Center
Çetrez-Iscan, Galibiye; Nurçin, Elçin; Fazlioglu, Yesim
2016-01-01
Dressing skill is one of the necessary self-care skills that is taught to individuals with autism in order for them to be able to live independently. Typically, developing individuals can acquire dressing skill on their own; however, children with autism have difficulties in learning such skill without systematic teaching. Thus, teaching dressing…
Review: Pressure-Induced Densification of Oxide Glasses at the Glass Transition
NASA Astrophysics Data System (ADS)
Kapoor, Saurabh; Wondraczek, Lothar; Smedskjaer, Morten M.
2017-02-01
Densification of oxide glasses at the glass transition offers a novel route to develop bulk glasses with tailored properties for emerging applications. Such densification can be achieved in the technologically relevant pressure regime of up to 1GPa. However, the present understanding of the composition-structure-property relationships governing these glasses is limited, with key questions, e.g., related to densification mechanism, remaining largely unanswered. Recent advances in structural characterization tools and high-pressure apparatuses have prompted new research efforts. Here, we review this recent progress and the insights gained in the understanding of the influence of isostatic compression at elevated temperature (so-called hot compression) on the composition-structure-property relationships of oxide glasses. We focus on compression at temperatures at or around the glass transition temperature (Tg), with relevant comparisons made to glasses prepared by pressure quenching and cold compression. We show that permanent densification at 1 GPa sets-in at temperatures above 0.7Tg and the degree of densification increases with increasing compression temperature and time, until attaining an approximately constant value for temperatures above Tg. For glasses compressed at the same temperature/pressure conditions, we demonstrate direct relations between the degree of volume densification and the pressure-induced change in micro-mechanical properties such as hardness, elastic moduli, and extent of the indentation size effect across a variety of glass families. Furthermore, we summarize the results on relaxation behavior of hot compressed glasses. All the pressure-induced changes in the structure and properties exhibit strong composition dependence. The experimental results highlight new opportunities for future investigation and identify research challenges that need to be overcome to advance the field.
Two-dimensional array of cold-electron bolometers for high-sensitivity polarization measurements
NASA Astrophysics Data System (ADS)
Kuzmin, L. S.
2012-01-01
A new concept of a two-dimensional array of cold-electron bolometers with distributed dipole antennas in the focal plane for high-sensitivity polarization measurements is proposed. The concept gives a unique combination of high polarization resolution due to a large uniforms array of cold-electron bolometers and optimal matching with junction field effect transistor (JFET) amplifiers because of flexibility in direct-current connections. The noise characteristics are improved due to arriving-signal power distribution among numerous cold-electron bolometers and an increase in their response. This should lead to a significant increase in the sensitivity and dynamic range compared with competing alternative bolometer technologies. The reliability of the twodimensional array significantly increases due to a series-parallel connection of a large number of cold-electron bolometers. High polarization resolution should be ensured due to uniform covering of a substrate by a two-dimensional array over a large area and the absence of the beam compression to small lumped elements. The fundamental sensitivity limit of the cold-electron bolometer array is smaller than photon noise which is considered to be the ultimate level restricted by the background radiation. Estimates of noise of bolometers with the JFET reading system show the possibility of realizing the ultimate sensitivity below the photon-noise level 5 ・10-17 W/Hz1/2 at a frequency of 350 GHz for an optical load with a power of 5 pW. These parameters correspond to the requirements to the receiving system of a BOOMERanG balloon telescope.
Davies, Phil
2016-01-01
Despite the implementation of prevention strategies, pressure ulcers (PUs) continue to be a challenging health problem for patients (and their carers), clinicians and health-care providers. One area of growing interest is the use of prophylactic dressings (which were originally designed for the treatment of PUs and other wound types) as a component of standard prevention measures. Over the past few years, a large amount of scientific and clinical data relating to this subject has been published in peer-reviewed journals and presented at international meetings and conferences. A substantial proportion of these data relate to one group of dressings: multi-layer foam dressings with Safetac, which are manufactured by Mölnlycke Health Care (Gothenburg, Sweden). This evidence pool has influenced the experts involved in updating the Clinical Practice Guideline, produced by the National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance, on the prevention and treatment of PUs. The updated Guideline, published in 2014, recommends that, as part of their PU prevention regimens, clinicians should consider applying prophylactic dressings to bony prominences in anatomical areas that are frequently subjected to friction and shear. A literature review was undertaken to identify clinical data from the entire evidence hierarchy, as well as scientific data from laboratory studies, on the use of multi-layer foam dressings with Safetac in the prevention of pressure ulceration. The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier B, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (i.e. oral, e-posters and posters) of relevance to the review. Clinical and health economic experts have undertaken numerous studies, including randomised controlled trials, to assess the efficacy and cost-effectiveness of using multi-layer foam dressings with Safetac as a component of standard PU prevention strategies. The results of these studies indicate that the application of multi-layer foam dressings containing Safetac can reduce the occurrence of PUs on anatomical locations such as the sacrum and the heel, and underneath medical devices. Scientists have also developed and used laboratory methods to gain a better understanding of how prophylactic dressings work. The results of these studies indicate that the composition of foam dressings containing Safetac (i.e. their multi-layer structure) sets them apart from other dressings due to their ability to mediate the effects of physical forces (i.e. pressure, friction and shear) and control microclimate, all of which contribute to pressure ulceration. The evidence pool clearly indicates that the prophylactic use of multi-layer foam dressings with Safetac as a component of standard prevention measures is beneficial to the clinician, the health-care provider and the patient. It should be noted that the findings outlined in this review may not be transferable to other products as their makeup and components are likely to differ significantly from those of multi-layer foam dressings with Safetac. As the importance of evidence-based practice and the need for cost-effective care continues to grow, clinicians and provider should carefully consider this point when selecting prophylactic dressings for PU prevention.
Santamaria, N; Gerdtz, M; Liu, W; Rakis, S; Sage, S; Ng, A W; Tudor, H; McCann, J; Vassiliou, T; Morrow, F; Smith, K; Knott, J; Liew, D
2015-08-01
Critically ill patients are at high risk of developing pressure ulcers (PU), with the sacrum and heels being highly susceptible to pressure injuries. The objective of our study was to evaluate the clinical effectiveness of a new multi-layer, self-adhesive soft silicone foam heel dressing to prevent PU development in trauma and critically ill patients in the intensive care unit (ICU). A cohort of critically ill patients were enrolled at the Royal Melbourne Hospital. Each patient had the multi-layer soft silicone foam dressing applied to each heel on admission to the emergency department. The dressings were retained with a tubular bandage for the duration of the patients' stay in the ICU. The skin under the dressings was examined daily and the dressings were replaced every three days. The comparator for our cohort study was the control group from the recently completed Border Trial. Of the 191 patients in the initial cohort, excluding deaths, loss to follow-up and transfers to another ward, 150 patients were included in the final analysis. There was no difference in key demographic or physiological variables between the cohorts, apart from a longer ICU length of stay for our current cohort. No PUs developed in any of our intervention cohort patients compared with 14 patients in the control cohort (n=152; p<0.001) who developed a total of 19 heel PUs. We conclude, based on our results, that the multi-layer soft silicone foam dressing under investigation was clinically effective in reducing ICU-acquired heel PUs. The findings also support previous research on the clinical effectiveness of multi-layer soft silicone foam dressings for PU prevention in the ICU.
The analytic structure of non-global logarithms: Convergence of the dressed gluon expansion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larkoski, Andrew J.; Moult, Ian; Neill, Duff Austin
Non-global logarithms (NGLs) are the leading manifestation of correlations between distinct phase space regions in QCD and gauge theories and have proven a challenge to understand using traditional resummation techniques. Recently, the dressed gluon ex-pansion was introduced that enables an expansion of the NGL series in terms of a “dressed gluon” building block, defined by an all-orders factorization theorem. Here, we clarify the nature of the dressed gluon expansion, and prove that it has an infinite radius of convergence as a solution to the leading logarithmic and large-N c master equation for NGLs, the Banfi-Marchesini-Smye (BMS) equation. The dressed gluonmore » expansion therefore provides an expansion of the NGL series that can be truncated at any order, with reliable uncertainty estimates. In contrast, manifest in the results of the fixed-order expansion of the BMS equation up to 12-loops is a breakdown of convergence at a finite value of α slog. We explain this finite radius of convergence using the dressed gluon expansion, showing how the dynamics of the buffer region, a region of phase space near the boundary of the jet that was identified in early studies of NGLs, leads to large contributions to the fixed order expansion. We also use the dressed gluon expansion to discuss the convergence of the next-to-leading NGL series, and the role of collinear logarithms that appear at this order. Finally, we show how an understanding of the analytic behavior obtained from the dressed gluon expansion allows us to improve the fixed order NGL series using conformal transformations to extend the domain of analyticity. Furthermore, this allows us to calculate the NGL distribution for all values of α slog from the coefficients of the fixed order expansion.« less
Fischer, Sebastian; Wall, Jennifer; Pomahac, Bohdan; Riviello, Robert; Halvorson, Eric G
2016-03-01
The use of negative-pressure-wound-therapy (NPWT) is associated with improved outcomes in smaller burns. We report our experience using extra-large (XL) NPWT dressings to treat ≥15% total body surface area (TBSA) burned and describe our technique and early outcomes. We also provide NPWT exudate volume for predictive fluid resuscitation in these critically ill patients. We retrospectively reviewed patients treated with XL-NPWT from 2012 to 2014. Following excision/grafting, graft and donor sites were sealed with a layered NPWT dressing. We documented wound size, dressing size, NPWT outputs, graft take, wound infections, and length of stay (LOS). Mean NPWT exudate volume per %TBSA per day was calculated. Twelve burn patients (mean TBSA burned 30%, range 15-60%) were treated with XL-NPWT (dressing TBSA burned and skin graft donor sites range 17-44%). Average graft take was 97%. No wound infections occurred. Two patients had burns ≥50% TBSA and their LOS was reduced compared to ABA averages. XL-NPWT outputs peaked at day 1 after grafting followed by a steady decline until dressings were removed. Average XL-NPWT dressing output during the first 5 days was 101±66mL/%BSA covered per day. 2 patients developed acute kidney injury. The use of XL-NPWT to treat extensive burns is feasible with attention to application technique. NPWT dressings appear to improve graft take, and to decrease risk of infection, LOS, and pain and anxiety associated with wound care. Measured fluid losses can improve patient care in future applications of NPWT to large burn wounds. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Mahoney, Diane Feeney; Coon, David W; Lozano, Cecil
2016-11-01
To gain an understanding of Latino/Hispanic caregivers' dementia-related dressing issues, their impressions of using a "smart" context-aware dresser to coach dressing, and recommendations to improve its acceptability. The same Latina moderator conducted all the caregiver focus groups. She followed a semi-structured interview guide that was previously used with White and African American family caregivers who experienced Alzheimer's disease related dressing challenges. From that study, the Preservation of Self model emerged. Using a deductive qualitative analytic approach, we applied the thematic domains from the Preservation of Self model to ascertain relevance to Latino/Hispanic caregivers. Twenty Latino/Hispanic experienced caregivers were recruited, enrolled, and participated in one of three focus groups. The majority were female (75%) and either the spouse (25%) or adult child (35%). Striking similarities occurred with the dressing challenges and alignment with the Preservation of Self model. Ethnic differences arose in concerns over assimilation weakening the Latino culture of family caregiving. Regional clothing preferences were noted. Technology improvement recommendations for our system, called DRESS, included developing bilingual prompting dialogs and video modules using the local vernacular to improve cultural sensitivity. Caregivers identified the potential for the technology to enable user privacy, empowerment, and exercise as well as offering respite time for themselves. Findings suggest dementia-related dressing issues were shared in common by different racial/ethnic groups but the response to them was influenced by cultural dynamics. For the first time Latino/Hispanic voices are heard to reflect their positive technology impressions, concerns, and recommendations in order to begin to address the cultural digital disparities divide.
Mahoney, Diane Feeney; Coon, David W; Lozano, Cecil
2016-01-01
Objective To gain an understanding of Latino/Hispanic caregivers’ dementia-related dressing issues, their impressions of using a “smart” context-aware dresser to coach dressing, and recommendations to improve its acceptability. Method The same Latina moderator conducted all the caregiver focus groups. She followed a semi-structured interview guide that was previously used with White and African American family caregivers who experienced Alzheimer’s disease related dressing challenges. From that study, the Preservation of Self model emerged. Using a deductive qualitative analytic approach, we applied the thematic domains from the Preservation of Self model to ascertain relevance to Latino/Hispanic caregivers. Results Twenty Latino/Hispanic experienced caregivers were recruited, enrolled, and participated in one of three focus groups. The majority were female (75%) and either the spouse (25%) or adult child (35%). Striking similarities occurred with the dressing challenges and alignment with the Preservation of Self model. Ethnic differences arose in concerns over assimilation weakening the Latino culture of family caregiving. Regional clothing preferences were noted. Technology improvement recommendations for our system, called DRESS, included developing bilingual prompting dialogs and video modules using the local vernacular to improve cultural sensitivity. Caregivers identified the potential for the technology to enable user privacy, empowerment, and exercise as well as offering respite time for themselves. Conclusion Findings suggest dementia-related dressing issues were shared in common by different racial/ethnic groups but the response to them was influenced by cultural dynamics. For the first time Latino/Hispanic voices are heard to reflect their positive technology impressions, concerns, and recommendations in order to begin to address the cultural digital disparities divide.
Walker, Michael; Bowler, Philip G; Cochrane, Christine A
2007-09-01
Excess or "uncontrolled" proteinase activity in the wound bed has been implicated as one factor that may delay or compromise wound healing. One proteinase group--matrix metalloproteinases--includes collagenases, elastase, and gelatinases and can be endogenous (cell) or exogenous (bacterial) in origin. A study was conducted to assess the ability of five silver-containing wound care products to reduce a known matrix metalloproteinase supernatant concentration in vitro. Four silver-containing wound dressings (a carboxy-methyl cellulose, a nanocrystalline, a hydro-alginate, and a collagen/oxidized regenerated cellulose composite dressing), along with a 0.5% aqueous silver nitrate [w/v] solution and controls for matrix metalloproteinase-2 and matrix metalloproteinase-9 sourced from ex vivo dermal tissue and blood monocytes, respectively, were used. Extracts were separated and purified using gelatine-Sepharose column chromatography and dialysis and polyacrylamide gel electrophoretic zymography was used to analyze specific matrix metalloproteinase activity. All dressings and the solution were shown to sequester both matrix metalloproteinases. The silver-containing carboxy-methyl cellulose dressing showed significantly greater sequestration for matrix metalloproteinase-2 at 6 and 24 hours (P< 0.001) compared to the other treatments. For matrix metalloproteinase-9, both the carboxy-methyl cellulose dressing and the oxidized regenerated cellulose dressing achieved significant sequestration when compared to the other treatments at 24 hours (P <0.001), which was maintained to 48 hours (P < 0.001). Results from this study show that silver-containing dressings are effective in sequestering matrix metalloproteinase-2 and -9 and that this can be achieved without a sacrificial protein (eg, collagen). Although the varying ability of wound dressings to sequester matrix metalloproteinases has been shown in vitro, further in vivo evidence is required to confirm these findings.
Management of Psychotropic Drug-Induced DRESS Syndrome: A Systematic Review.
Bommersbach, Tanner J; Lapid, Maria I; Leung, Jonathan G; Cunningham, Julie L; Rummans, Teresa A; Kung, Simon
2016-06-01
Drug rash with eosinophilia and systemic symptoms (DRESS) is a severe cutaneous eruption that has been linked to several common drugs and drug categories, including antiepileptics, allopurinol, sulfonamides, and various antibiotics; however, because of a number of recent case reports linking psychotropic medications to this condition, DRESS is increasingly recognized among psychiatrists. We systematically reviewed all psychotropic drugs linked to DRESS syndrome, and this article summarizes the clinical management relevant to psychiatric professionals. A comprehensive search was performed using Ovid MEDLINE, Ovid EMBASE, Ovid Cochrane Database of Systematic Reviews, Web of Science, Scopus, and Litt's Drug Eruption and Reaction Database for articles published in English during the past 20 years (1996-2015) using the search terms (1) psychotropic drugs OR serotonin uptake inhibitors AND DRESS or (2) psychotropic drugs AND drug reaction (or rash) eosinophilia systemic syndrome, and all article abstracts were screened for inclusion and exclusion criteria by 3 reviewers. Two independent reviewers examined the full text of 163 articles, of which 96 (25 original articles, 12 review articles, 55 case reports, and 4 letters to the editor) were included in the systematic review. We identified 1072 cases of psychotropic drug-induced DRESS, with carbamazepine, lamotrigine, phenytoin, valproate, and phenobarbital being the most implicated drugs. Based on our review of the literature, we outline management principles that include prompt withdrawal of the causative drug, hospitalization, corticosteroid therapy, and novel treatments, including intravenous immunoglobulin, cyclophosphamide, and cyclosporine, for corticosteroid-resistant DRESS. Finally, we outline strategies for treating comorbid psychiatric illness after a DRESS reaction to the psychotropic medication. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Karlsson, Bodil S A; Allwood, Carl Martin
2016-01-01
The Dress photograph, first displayed on the internet in 2015, revealed stunning individual differences in color perception. The aim of this study was to investigate if lay-persons believed that the question about The Dress colors was answerable. Past research has found that optimism is related to judgments of how answerable knowledge questions with controversial answers are (Karlsson et al., 2016). Furthermore, familiarity with a question can create a feeling of knowing the answer (Reder and Ritter, 1992). Building on these findings, 186 participants saw the photo of The Dress and were asked about the correct answer to the question about The Dress' colors (" blue and black," "white and gold," "other, namely…," or "there is no correct answer" ). Choice of the alternative "there is no correct answer" was interpreted as believing the question was not answerable. This answer was chosen more often by optimists and by people who reported they had not seen The Dress before. We also found that among participants who had seen The Dress photo before, 19%, perceived The Dress as "white and gold" but believed that the correct answer was "blue and black ." This, in analogy to previous findings about non-believed memories (Scoboria and Pascal, 2016), shows that people sometimes do not believe the colors they have perceived are correct. Our results suggest that individual differences related to optimism and previous experience may contribute to if the judgment of the individual perception of a photograph is enough to serve as a decision basis for valid conclusions about colors. Further research about color judgments under ambiguous circumstances could benefit from separating individual perceptual experience from beliefs about the correct answer to the color question. Including the option "there is no correct answer " may also be beneficial.
The analytic structure of non-global logarithms: Convergence of the dressed gluon expansion
Larkoski, Andrew J.; Moult, Ian; Neill, Duff Austin
2016-11-15
Non-global logarithms (NGLs) are the leading manifestation of correlations between distinct phase space regions in QCD and gauge theories and have proven a challenge to understand using traditional resummation techniques. Recently, the dressed gluon ex-pansion was introduced that enables an expansion of the NGL series in terms of a “dressed gluon” building block, defined by an all-orders factorization theorem. Here, we clarify the nature of the dressed gluon expansion, and prove that it has an infinite radius of convergence as a solution to the leading logarithmic and large-N c master equation for NGLs, the Banfi-Marchesini-Smye (BMS) equation. The dressed gluonmore » expansion therefore provides an expansion of the NGL series that can be truncated at any order, with reliable uncertainty estimates. In contrast, manifest in the results of the fixed-order expansion of the BMS equation up to 12-loops is a breakdown of convergence at a finite value of α slog. We explain this finite radius of convergence using the dressed gluon expansion, showing how the dynamics of the buffer region, a region of phase space near the boundary of the jet that was identified in early studies of NGLs, leads to large contributions to the fixed order expansion. We also use the dressed gluon expansion to discuss the convergence of the next-to-leading NGL series, and the role of collinear logarithms that appear at this order. Finally, we show how an understanding of the analytic behavior obtained from the dressed gluon expansion allows us to improve the fixed order NGL series using conformal transformations to extend the domain of analyticity. Furthermore, this allows us to calculate the NGL distribution for all values of α slog from the coefficients of the fixed order expansion.« less
Hierarchy of Dysfunction Related to Dressing Performance in Stroke Patients: A Path Analysis Study.
Fujita, Takaaki; Nagayama, Hirofumi; Sato, Atsushi; Yamamoto, Yuichi; Yamane, Kazuhiro; Otsuki, Koji; Tsuchiya, Kenji; Tozato, Fusae
2016-01-01
Previous reports indicated that various dysfunctions caused by stroke affect the level of independence in dressing. These dysfunctions can be hierarchical, and these effects on dressing performance can be complicated in stroke patients. However, there are no published reports focusing on the hierarchical structure of the relationships between the activities of daily living and balance function, motor and sensory functions of the affected lower limb, strength of the abdominal muscles and knee extension on the unaffected side, and visuospatial deficits. The purpose of this study was to elucidate the hierarchical and causal relationships between dressing performance and these dysfunctions in stroke patients. This retrospective study included 104 first-time stroke patients. The causal relationship between the dressing performance and age, time post stroke, balance function, motor and sensory functions of the affected lower limb, strength of the abdominal muscles and knee extension on the unaffected side, and visuospatial deficits were examined using path analysis. A hypothetical path model was created based on previous studies, and the goodness of fit between the data and model were verified. A modified path model was created that achieved an almost perfect fit to the data. Balance function and abdominal muscle strength have direct effects on dressing performance, with standardized direct effect estimates of 0.78 and 0.15, respectively. Age, motor and sensory functions of the affected lower limb, and strength of abdominal muscle and knee extension on the unaffected side have indirect effects on dressing by influencing balance function. Our results suggest that dressing performance depends strongly on balance function, and it is mainly influenced by the motor function of the affected lower limb.
Bikmoradi, Ali; Harorani, Mehdi; Roshanaei, Ghodratollah; Moradkhani, Shirin; Falahinia, Golam Hossein
2016-01-01
Background: Pain is one of the common problems encountered by patients with burns, which increases after each dressing. This study aimed to investigate the effect of inhalation aromatherapy with damask rose essence on the pain of patients with burns that is caused after dressing. Materials and Methods: A randomized clinical trial was conducted on 50 patients with second- and third-degree burn wounds. The baseline pain of the patients was assessed 30 min before they entered into the dressing room on the first and second days of intervention. The patients in the experimental group inhaled five drops of damask rose essence 40% in distilled water, while those in the control group inhaled five drops of distilled water as placebo. The pain intensity was assessed using Visual Analogue Scale at 15 and 30 min after the patients exited from the dressing room. Data were analyzed by SPSS (version 18) using descriptive and inferential statistics. Results: There was significant difference between the mean of pain intensity before and after intervention at 15 and 30 min after dressing (P < 0.001). Moreover, there was significant difference in reduction of pain intensity before and after aromatherapy in the experimental group (P < 0.05). Also, there was a significant reduction in severity of pain after dressing in the experimental group compared with the control group (P < 0.05). Conclusions: Inhalation aromatherapy with damask rose could be effective for relieving the pain caused after dressing in patients with burns. Therefore, it could be suggested as a complementary therapy in burn patients for pain relief. PMID:27186201
A dressed spin qubit in silicon
Laucht, Arne; Kalra, Rachpon; Simmons, Stephanie; ...
2016-10-17
Coherent dressing of a quantum two-level system provides access to a new quantum system with improved properties—a different and easily tunable level splitting, faster control and longer coherence times. In our work we investigate the properties of the dressed, donor-bound electron spin in silicon, and assess its potential as a quantum bit in scalable architectures. The two dressed spin-polariton levels constitute a quantum bit that can be coherently driven with an oscillating magnetic field, an oscillating electric field, frequency modulation of the driving field or a simple detuning pulse. We measure coherence times of T* 2p = 2.4 ms andmore » T Hahn 2p = 9 ms, one order of magnitude longer than those of the undressed spin. Moreover, the use of the dressed states enables coherent coupling of the solid-state spins to electric fields and mechanical oscillations.« less
Dressings as an adjunct to pressure ulcer prevention: consensus panel recommendations.
Black, Joyce; Clark, Michael; Dealey, Carol; Brindle, Christopher T; Alves, Paulo; Santamaria, Nick; Call, Evan
2015-08-01
The formulation of recommendations on the use of wound dressings in pressure ulcer prevention was undertaken by a group of experts in pressure ulcer prevention and treatment from Australia, Portugal, UK and USA. After review of literature, they concluded that there is adequate evidence to recommend the use of five-layer silicone bordered dressings (Mepilex Border Sacrum(®) and 3 layer Mepilex Heel(®) dressings by Mölnlycke Health Care, Gothenburg, Sweden) for pressure ulcer prevention in the sacrum, buttocks and heels in high-risk patients, those in Emergency Department (ED), intensive care unit (ICU) and operating room (OR). Literature on which this recommendation is based includes one prospective randomised control trial, three cohort studies and two case series. Recommendations for dressing use in patients at high risk for pressure injury and shear injury were also provided. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Wiegand, C; Abel, M; Ruth, P; Hipler, U C
2011-11-01
A comprehensive in vitro approach was used to assess the effects of superabsorbent polymer (SAP) containing wound dressings in treatment of non-healing wounds. A slight negative effect on HaCaT cells was noted in vitro which is most likely due to the Ca(2+) deprivation of the medium by binding to the SAP. It could be shown that SAP wound dressings are able to bind considerable amounts of elastase reducing enzyme activity significantly. Furthermore, SAP's inhibit the formation of free radicals. The SAP-containing wound dressings tested also exhibited a significant to strong antimicrobial activity effectively impeding the growth of gram-negative and gram-positive bacteria as well as yeasts. In conclusion, in vitro data confirm the positive effect of SAP wound dressings observed in vivo and suggest that they should be specifically useful for wound cleansing.
A privacy-preserving solution for compressed storage and selective retrieval of genomic data.
Huang, Zhicong; Ayday, Erman; Lin, Huang; Aiyar, Raeka S; Molyneaux, Adam; Xu, Zhenyu; Fellay, Jacques; Steinmetz, Lars M; Hubaux, Jean-Pierre
2016-12-01
In clinical genomics, the continuous evolution of bioinformatic algorithms and sequencing platforms makes it beneficial to store patients' complete aligned genomic data in addition to variant calls relative to a reference sequence. Due to the large size of human genome sequence data files (varying from 30 GB to 200 GB depending on coverage), two major challenges facing genomics laboratories are the costs of storage and the efficiency of the initial data processing. In addition, privacy of genomic data is becoming an increasingly serious concern, yet no standard data storage solutions exist that enable compression, encryption, and selective retrieval. Here we present a privacy-preserving solution named SECRAM (Selective retrieval on Encrypted and Compressed Reference-oriented Alignment Map) for the secure storage of compressed aligned genomic data. Our solution enables selective retrieval of encrypted data and improves the efficiency of downstream analysis (e.g., variant calling). Compared with BAM, the de facto standard for storing aligned genomic data, SECRAM uses 18% less storage. Compared with CRAM, one of the most compressed nonencrypted formats (using 34% less storage than BAM), SECRAM maintains efficient compression and downstream data processing, while allowing for unprecedented levels of security in genomic data storage. Compared with previous work, the distinguishing features of SECRAM are that (1) it is position-based instead of read-based, and (2) it allows random querying of a subregion from a BAM-like file in an encrypted form. Our method thus offers a space-saving, privacy-preserving, and effective solution for the storage of clinical genomic data. © 2016 Huang et al.; Published by Cold Spring Harbor Laboratory Press.
Heat Treatment of Cold-Sprayed C355 Al for Repair: Microstructure and Mechanical Properties
NASA Astrophysics Data System (ADS)
Murray, J. W.; Zuccoli, M. V.; Hussain, T.
2018-01-01
Cold gas dynamic spraying of commercially pure aluminum is widely used for dimensional repair in the aerospace sector as it is capable of producing oxide-free deposits of hundreds of micrometer thickness with strong bonding to the substrate, based on adhesive pull-off tests, and often with enhanced hardness compared to the powder prior to spraying. There is significant interest in extending this application to structural, load-bearing repairs. Particularly, in the case of high-strength aluminum alloys, cold spray deposits can exhibit high levels of porosity and microcracks, leading to mechanical properties that are inadequate for most load-bearing applications. Here, heat treatment was investigated as a potential means of improving the properties of cold-sprayed coatings from Al alloy C355. Coatings produced with process conditions of 500 °C and 60 bar were heat-treated at 175, 200, 225, 250 °C for 4 h in air, and the evolution of the microstructure and microhardness was analyzed. Heat treatment at 225 and 250 °C revealed a decreased porosity ( 0.14% and 0.02%, respectively) with the former yielding slightly reduced hardness (105 versus 130 HV0.05 as-sprayed). Compressive residual stress levels were approximately halved at all depths into the coating after heat treatment, and tensile testing showed an improvement in ductility.
Dress Fashion in Feminist and Child Rights Campaigns in Ghanaian Public Sculptures of the 1990s
ERIC Educational Resources Information Center
Essel, Osuanyi Quaicoo; Opoku-Mensah, Isaac
2017-01-01
This article examines how dress fashion in outdoor sculptures of the 1990s in the Accra cityscape accentuated feminist activism, sensitised child right campaigns, and encouraged girl-child education in support of governmental efforts and activism of civil society organisations in Ghana. It gives attention to how dress fashion of the time was used…
USDA-ARS?s Scientific Manuscript database
An intelligent dressing is a self-adjusting material with multifunctional properties and/or a biosensor-interface designed to treat specific pathological issues of wounds at a molecular or cellular level. The ability to detect and treat excessive protease levels in wounds, one indicator of chronic w...
ERIC Educational Resources Information Center
Sebastian, Richard J.; Bristow, Dennis
2008-01-01
In this article, the authors examine the effects of style of dress, forms of address, and gender of the stimulus person on business students' perceptions of professors' attributes. Student participants (125 women, 132 men) rated the stimulus person on indexes of attractiveness, trustworthiness, credibility, and likeability. Style of dress and form…
Politicas de uniformes y codigos de vestuario (Uniforms and Dress-Code Policies). ERIC Digest.
ERIC Educational Resources Information Center
Lumsden, Linda
This digest in Spanish examines schools' dress-code policies and discusses the legal considerations and research findings about the effects of such changes. Most revisions to dress codes involve the use of uniforms, typically as a way to curb school violence and create a positive learning environment. A recent survey of secondary school principals…
Dressing control of biphoton waveform transitions
NASA Astrophysics Data System (ADS)
Li, Xinghua; Zhang, Dan; Zhang, Da; Hao, Ling; Chen, Haixia; Wang, Zhiguo; Zhang, Yanpeng
2018-05-01
We experimentally realize and theoretically analyze narrow-band biphotons generated in a hot rubidium vapor cell by four-wave-mixing processing. A dressing laser beam is used to alternate both linear and nonlinear susceptibilities of the vapor, thereby modifying the biphoton's temporal correlation function. Most notably, the correlation time is increased from 6 to 165 ns. The biphoton shape is also shown to change as a result of the coupled-states dressing. We observed Rabi oscillations and optical precursors in hot atomic vapor cells. We also theoretically simulated biphoton correlation times as influenced by dressing-laser detuning and power, the results of which are consistent with our experiments.
Evidence review: the clinical benefits of Safetac technology in wound care.
Davies, Phil; Rippon, Mark
2008-11-01
Common causes of trauma and wound pain include: the removal of dressings that become stuck to the wound bed; skin stripping of peri-wound skin, as a result of the repeated application and removal of adhesive dressings; and tissue excoriation and maceration of the peri-wound skin, due to inadequate management of wound exudate. This supplement outlines how dressings with Safetac adhesive technology can help clinicians to avoid these problems. A review of the clinical and scientific evidence relating to dressings with Safetac clearly demonstrates that they can be used to prevent trauma and minimise pain on a wide range of wound types and skin injuries.
The Concept of Fashion Design on the Basis of Color Coordination Using White LED Lighting
NASA Astrophysics Data System (ADS)
Mizutani, Yumiko; Taguchi, Tsunemasa
This thesis focuses on the development of fashion design, especially a dress coordinated with White LED Lighting (=LED). As for the design concept a fusion of the advanced science and local culture was aimed for. For such a reason this development is a very experimental one. Here in particular I handled an Imperial Court dinner dress for the last Japanese First Lady, Mrs. Akie Abe who wore it at the Imperial Court dinner for the Indonesian First Couple held on November 2006 to. This dress made by Prof. T. Taguchi and I open up a new field in the dress design.
Dutra, R A A; Salomé, G M; Leal, L M F; Alves, M G; Moura, J P; Silva, A T; Pereira, V O S; de Brito, M J A; Ferreira, L M
2016-11-02
To evaluate and compare the costs of using a transparent polyurethane film (PF) and hydrocolloid dressing (HD) in the prevention of pressure ulcers (PUs). This descriptive, observational, longitudinal, comparative study was conducted in the intensive care units, coronary care unit and medical clinic of a charity hospital in Brazil. Data were collected during a 30-day study period, consisting of physical examination, assessment of risk factors for PU development and application of the Braden scale, which were performed at inclusion in the study and once daily during hospitalisation. Either PF or HD was applied bilaterally in the sacral and trochanteric regions for prevention of PUs in patients at a moderate to high risk of PUs according to the Braden scale, and costs of using PU preventive dressings were estimated. The mean total costs per dressing change per patient when using the HD and PF to prevent PUs were 413.60 BRL and 74.04 BRL, respectively. There were significant between-group differences in mean costs for all variables, except for saline solution and nurse-technician services. Results showed that the mean cost per dressing change per patient was lower when using the transparent PF than when using the HD.