Partial oxidation for improved cold starts in alcohol-fueled engines: Phase 2 topical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-01
Alcohol fuels exhibit poor cold-start performance because of their low volatility. Neat alcohol engines become difficult, if not impossible, to start at temperatures close to or below freezing. Improvements in the cold-start performance (both time to start and emissions) are essential to capture the full benefits of alcohols as an alternative transportation fuel. The objective of this project was to develop a neat alcohol partial oxidation (POX) reforming technology to improve an alcohol engine`s ability to start at low temperatures (as low as {minus}30 C) and to reduce its cold-start emissions. The project emphasis was on fuel-grade ethanol (E95) butmore » the technology can be easily extended to other alcohol fuels. Ultimately a compact, on-vehicle, ethanol POX reactor was developed as a fuel system component to produce a hydrogen-rich, fuel-gas mixture for cold starts. The POX reactor is an easily controllable combustion device that allows flexibility during engine startup even in the most extreme conditions. It is a small device that is mounted directly onto the engine intake manifold. The gaseous fuel products (or reformate) from the POX reactor exit the chamber and enter the intake manifold, either replacing or supplementing the standard ethanol fuel consumed during an engine start. The combustion of the reformate during startup can reduce engine start time and tail-pipe emissions.« less
Cold-start characteristics of polymer electrolyte fuel cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishler, Jeff; Mukundan, Rangachary; Wang, Yun
2010-01-01
In this paper, we investigate the electrochemical reaction kinetics, species transport, and solid water dynamics in a polymer electrolyte fuel cell (PEFC) during cold start. A simplitied analysis is developed to enable the evaluation of the impact of ice volume fraction on cell performance during coldstart. Supporting neutron imaging data are also provided to reveal the real-time water evolution. Temperature-dependent voltage changes due to the reaction kinetics and ohmic loss are also analyzed based on the ionic conductivity of the membrane at subfreezing temperature. The analysis is valuable for the fundamental study of PEFC cold-start.
Drozd, Greg T; Zhao, Yunliang; Saliba, Georges; Frodin, Bruce; Maddox, Christine; Weber, Robert J; Chang, M-C Oliver; Maldonado, Hector; Sardar, Satya; Robinson, Allen L; Goldstein, Allen H
2016-12-20
Experiments were conducted at the California Air Resources Board Haagen-Smit Laboratory to understand changes in vehicle emissions in response to stricter emissions standards over the past 25 years. Measurements included a wide range of volatile organic compounds (VOCs) for a wide range of spark ignition gasoline vehicles meeting varying levels of emissions standards, including all certifications from Tier 0 up to Partial Zero Emission Vehicle. Standard gas chromatography (GC) and high performance liquid chromatography (HLPC) analyses were employed for drive-cycle phase emissions. A proton-transfer-reaction mass spectrometer measured time-resolved emissions for a wide range of VOCs. Cold-start emissions occur almost entirely in the first 30-60 s for newer vehicles. Cold-start emissions have compositions that are not significantly different across all vehicles tested and are markedly different from neat fuel. Hot-stabilized emissions have varying importance depending on species and may require a driving distance of 200 miles to equal the emissions from a single cold start. Average commute distances in the U.S. suggest the majority of in-use vehicles have emissions dominated by cold starts. The distribution of vehicle ages in the U.S. suggests that within several years only a few percent of vehicles will have significant driving emissions compared to cold-start emissions.
The cold driver: Cold stress while driving results in dangerous behavior.
Morris, Drew M; Pilcher, June J
2016-10-01
Cool vehicle cabin temperatures can induce short-term non-hypothermic cold stress. The current study created a cold condition to examine the impact of cold stress on driving behavior. Forty-four participants drove a high-fidelity driving simulator during a thermal neutral or local torso cooled condition. Participants performed additional tasks to assess attention, psychomotor vigilance, and manual dexterity. Skin temperature was significantly lower in the cold condition while internal temperature was unaffected. Participants who had higher subjective ratings of cold followed lead vehicles closer and started to brake later. Participants in the cold condition followed the lead car 22% (0.82s) closer and started braking 20% (2.35s) later when approaching a stop sign during the car-following task. No change in attention, psychomotor vigilance, or dexterity was observed. The current results suggest that cold environmental conditions can contribute to dangerous driving behaviors. Measures of cold perception were also shown to predict changes in driving behavior. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Clenci, Adrian; Niculescu, Rodica; Iorga-Simǎn, Victor; Tricǎ, Alina; Danlos, Amélie
2017-02-01
The use of biodiesel fuel in compression ignition engines has the potential to reduce CO2, which can lead to a reduction in global warming and environmental hazards. Biodiesel is an attractive fuel, as it is made from renewable resources. A major drawback associated with the use of biodiesel, however, is its poor cold flow properties, which have a direct influence on the cold starting performance of the engine. This paper is a consequence of a study on assessing the cold-starting performance of a compression ignition engine fueled with different blends of fossil diesel fuel and biodiesel. Through experimental investigations, it was found that the engine starting at -20°C was no longer possible in the case of using B50 (50% diesel + 50% biofuel made from sunflower oil). In order to "force" the engine starting in this particular situation, Di-Ethyl-Ether (DEE) was injected into the intake manifold. DEE being a highly flammable substance, the result was a sudden and explosive engine starting, the peak pressure in the monitored cylinder in the first successful engine cycle being almost twice the one which is usually considered as normal. Thus, to explain the observed phenomena, we launched this work relying on the analysis of the in-cylinder instantaneous pressure evolution, which was acquired during cranking, stabilizing and idling phases. Moreover, since the cause of the sudden and explosive engine starting was the DEE, by using a CFD approach, we also obtained results regarding the inter-cylinder distribution of the injected DEE.
A personal sampler for aircraft engine cold start particles: laboratory development and testing.
Armendariz, Alfredo; Leith, David
2003-01-01
Industrial hygienists in the U.S. Air Force are concerned about exposure of their personnel to jet fuel. One potential source of exposure for flightline ground crews is the plume emitted during the start of aircraft engines in extremely cold weather. The purpose of this study was to investigate a personal sampler, a small tube-and-wire electrostatic precipitator (ESP), for assessing exposure to aircraft engine cold start particles. Tests were performed in the laboratory to characterize the sampler's collection efficiency and to determine the magnitude of adsorption and evaporation artifacts. A low-temperature chamber was developed for the artifact experiments so tests could be performed at temperatures similar to actual field conditions. The ESP collected particles from 0.5 to 20 micro m diameter with greater than 98% efficiency at particle concentrations up to 100 mg/m(3). Adsorption artifacts were less than 5 micro g/m(3) when sampling a high concentration vapor stream. Evaporation artifacts were significantly lower for the ESP than for PVC membrane filters across a range of sampling times and incoming vapor concentrations. These tests indicate that the ESP provides more accurate exposure assessment results than traditional filter-based particle samplers when sampling cold start particles produced by an aircraft engine.
Bongoni, Radhika; Verkerk, Ruud; Steenbekkers, Bea; Dekker, Matthijs; Stieger, Markus
2014-09-01
The objective of this study was to gain insights into the effect of the cooking method on the liking as well as the retention of glucosinolates in broccoli. With this knowledge it can be concluded whether the health aspects of broccoli be improved by the cooking method without deteriorating sensory perception. For this, broccoli was cooked by methods commonly applied by consumers: boiling with a cold (water) start; boiling with a hot (water) start; and steaming. Firmness, greenness and amount of total glucosinolates in cooked broccoli were instrumentally determined. Sensory evaluation by untrained consumers (n = 99) for liking and sensory attributes intensity rating were performed on broccoli cooked by steaming and boiling-cold start at three time points, which resulted in 'high', 'medium', 'low' firm broccoli samples. At the end of cooking, steaming showed an increase in the amount of total glucosinolates (+17%). Boiling-hot start (-41%) and boiling-cold start (-50%) showed a decrease in amount of total glucosinolates. Sensory evaluation did not show statistically significant differences between steaming and boiling-cold start in liking at 'high' and 'medium' firmness; and in the attribute intensity ratings (except for juiciness at 'medium' firmness, and flavour at 'medium' and 'low' firmness). This study demonstrates that medium firm broccoli showed optimum liking and that steaming compared to boiled-cold start showed higher amount of glucosinolates. It is concluded that the health aspects of broccoli can be improved without reducing the sensory aspects by optimising the cooking method.
Impact of cold climates on vehicle emissions: the cold start air toxics pulse : final report.
DOT National Transportation Integrated Search
2016-09-21
This project measured cold start emissions from four vehicles in winter using fast response instrumentation to accurately measure the : time variation of the cold start emission pulse. Seventeen successful tests were conducted over a temperature rang...
Autoignition Chamber for Remote Testing of Pyrotechnic Devices
NASA Technical Reports Server (NTRS)
Harrington, Maureen L.; Steward, Gerald R.; Dartez, Toby W.
2009-01-01
The autoignition chamber (AIC) performs by remotely heating pyrotechnic devices that can fit the inner diameter of the tube furnace. Two methods, a cold start or a hot start, can be used with this device in autoignition testing of pyrotechnics. A cold start means extending a pyrotechnic device into the cold autoignition chamber and then heating the device until autoignition occurs. A hot start means heating the autoignition chamber to a specified temperature, and then extending the device into a hot autoignition chamber until autoignition occurs. Personnel are remote from the chamber during the extension into the hot chamber. The autoignition chamber, a commercially produced tubular furnace, has a 230-V, single-phase, 60-Hz electrical supply, with a total power output of 2,400 W. It has a 6-in. (15.2-cm) inner diameter, a 12-in. (30.4-cm) outer diameter and a 12-in.- long (30.4-cm), single-zone, solid tubular furnace (element) capable of heating to temperatures up to 2,012 F (1,100 C) in air.
High Time Resolution Measurements of VOCs from Vehicle Cold Starts: The Air Toxic Cold Start Pulse
NASA Astrophysics Data System (ADS)
Jobson, B. T.; Huangfu, Y.; Vanderschelden, G. S.
2017-12-01
Pollutants emitted during motor vehicle cold starts, especially in winter in some climates, is a significant source of winter time air pollution. While data exist for CO, NO, and total hydrocarbon emissions from federal testing procedures for vehicle emission certification, little is known about the emission rates of individual volatile organic compounds, in particular the air toxics benzene, formaldehyde, and acetaldehyde. Little is known about the VOC speciation and temperature dependence for cold starts. The US EPA vehicle emission model MOVES assumes that cold start emissions have the same speciation profile as running emissions. We examined this assumption by measuring cold start exhaust composition for 4 vehicles fueled with E10 gasoline over a temperature range of -4°C to 10°C in winter of 2015. The extra cold start emissions were determined by comparison with emissions during engine idling. In addition to CO and NOx measurements a proton transfer reaction mass spectrometer was used to measure formaldehyde, acetaldehyde, benzene, toluene, and C2-alkylbenzenes at high time resolution to compare with the cold start emission speciation profiles used in the EPA MOVES2014 model. The results show that after the vehicle was started, CO mixing ratios can reach a few percent of the exhaust and then drop to several ppmv within 2 minutes of idling, while NOx showed different temporal behaviors among the four vehicles. VOCs displayed elevated levels during cold start and the peak mixing ratios can be two orders higher than idling phase levels. Molar emission ratios relative to toluene were used to compare with the emission ratio used in MOVES2014 and we found the formaldehyde-to-toluene emission ratio was about 0.19, which is 5 times higher than the emission ratio used in MOVES2014 and the acetaldehyde-to-toluene emission ratios were 0.86-0.89, which is 8 times higher than the ones in MOVES2014. The C2-alkylbenzene-to-toluene ratio agreed well with moves. Our results suggest that for the air toxics acetaldehyde and formaldehyde, wintertime cold temperature vehicle start emissions are likely significantly underestimated in the MOVES 2014 model.
NASA Astrophysics Data System (ADS)
Bejarano, Roberto Villa
Cold-start performance enhancement of a pump-assisted, capillary-driven, two-phase cooling loop was attained using proportional integral and fuzzy logic controls to manage the boiling condition inside the evaporator. The surface tension of aqueous solutions of n-Pentanol, a self-rewetting fluid, was also investigated for enhancing heat transfer performance of capillary driven (passive) thermal devices was also studied. A proportional-integral control algorithm was used to regulate the boiling condition (from pool boiling to thin-film boiling) and backpressure in the evaporator during cold-start and low heat input conditions. Active flow control improved the thermal resistance at low heat inputs by 50% compared to the baseline (constant flow rate) case, while realizing a total pumping power savings of 56%. Temperature overshoot at start-up was mitigated combining fuzzy-logic with a proportional-integral controller. A constant evaporator surface temperature of 60°C with a variation of +/-8°C during start-up was attained with evaporator thermal resistances as low as 0.10 cm2--K/W. The surface tension of aqueous solutions of n-Pentanol, a self-rewetting working fluid, as a function of concentration and temperature were also investigated. Self-rewetting working fluids are promising in two-phase heat transfer applications because they have the ability to passively drive additional working fluid towards the heated surface; thereby increasing the dryout limitations of the thermal device. Very little data is available in literature regarding the surface tension of these fluids due to the complexity involved in fluid handling, heating, and experimentation. Careful experiments were performed to investigate the surface tension of n-Pentanol + water. The concentration and temperature range investigated were from 0.25%wt. to1.8%wt and 25°C to 85°C, respectively.
TrustRank: a Cold-Start tolerant recommender system
NASA Astrophysics Data System (ADS)
Zou, Haitao; Gong, Zhiguo; Zhang, Nan; Zhao, Wei; Guo, Jingzhi
2015-02-01
The explosive growth of the World Wide Web leads to the fast advancing development of e-commerce techniques. Recommender systems, which use personalised information filtering techniques to generate a set of items suitable to a given user, have received considerable attention. User- and item-based algorithms are two popular techniques for the design of recommender systems. These two algorithms are known to have Cold-Start problems, i.e., they are unable to effectively handle Cold-Start users who have an extremely limited number of purchase records. In this paper, we develop TrustRank, a novel recommender system which handles the Cold-Start problem by leveraging the user-trust networks which are commonly available for e-commerce applications. A user-trust network is formed by friendships or trust relationships that users specify among them. While it is straightforward to conjecture that a user-trust network is helpful for improving the accuracy of recommendations, a key challenge for using user-trust network to facilitate Cold-Start users is that these users also tend to have a very limited number of trust relationships. To address this challenge, we propose a pre-processing propagation of the Cold-Start users' trust network. In particular, by applying the personalised PageRank algorithm, we expand the friends of a given user to include others with similar purchase records to his/her original friends. To make this propagation algorithm scalable to a large amount of users, as required by real-world recommender systems, we devise an iterative computation algorithm of the original personalised TrustRank which can incrementally compute trust vectors for Cold-Start users. We conduct extensive experiments to demonstrate the consistently improvement provided by our proposed algorithm over the existing recommender algorithms on the accuracy of recommendations for Cold-Start users.
Promoting Cold-Start Items in Recommender Systems
Liu, Jin-Hu; Zhou, Tao; Zhang, Zi-Ke; Yang, Zimo; Liu, Chuang; Li, Wei-Min
2014-01-01
As one of the major challenges, cold-start problem plagues nearly all recommender systems. In particular, new items will be overlooked, impeding the development of new products online. Given limited resources, how to utilize the knowledge of recommender systems and design efficient marketing strategy for new items is extremely important. In this paper, we convert this ticklish issue into a clear mathematical problem based on a bipartite network representation. Under the most widely used algorithm in real e-commerce recommender systems, the so-called item-based collaborative filtering, we show that to simply push new items to active users is not a good strategy. Interestingly, experiments on real recommender systems indicate that to connect new items with some less active users will statistically yield better performance, namely, these new items will have more chance to appear in other users' recommendation lists. Further analysis suggests that the disassortative nature of recommender systems contributes to such observation. In a word, getting in-depth understanding on recommender systems could pave the way for the owners to popularize their cold-start products with low costs. PMID:25479013
Promoting cold-start items in recommender systems.
Liu, Jin-Hu; Zhou, Tao; Zhang, Zi-Ke; Yang, Zimo; Liu, Chuang; Li, Wei-Min
2014-01-01
As one of the major challenges, cold-start problem plagues nearly all recommender systems. In particular, new items will be overlooked, impeding the development of new products online. Given limited resources, how to utilize the knowledge of recommender systems and design efficient marketing strategy for new items is extremely important. In this paper, we convert this ticklish issue into a clear mathematical problem based on a bipartite network representation. Under the most widely used algorithm in real e-commerce recommender systems, the so-called item-based collaborative filtering, we show that to simply push new items to active users is not a good strategy. Interestingly, experiments on real recommender systems indicate that to connect new items with some less active users will statistically yield better performance, namely, these new items will have more chance to appear in other users' recommendation lists. Further analysis suggests that the disassortative nature of recommender systems contributes to such observation. In a word, getting in-depth understanding on recommender systems could pave the way for the owners to popularize their cold-start products with low costs.
40 CFR 86.1336-84 - Engine starting, restarting, and shutdown.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (4) If a failure to start occurs during the hot start portion of the test and is caused by engine... stalling. (1) If the engine stalls during the initial idle period of either the cold or hot start test, the engine shall be restarted immediately using the appropriate cold or hot starting procedure and the test...
40 CFR 86.1336-84 - Engine starting, restarting, and shutdown.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (4) If a failure to start occurs during the hot start portion of the test and is caused by engine... stalling. (1) If the engine stalls during the initial idle period of either the cold or hot start test, the engine shall be restarted immediately using the appropriate cold or hot starting procedure and the test...
40 CFR 86.1336-84 - Engine starting, restarting, and shutdown.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (4) If a failure to start occurs during the hot start portion of the test and is caused by engine... stalling. (1) If the engine stalls during the initial idle period of either the cold or hot start test, the engine shall be restarted immediately using the appropriate cold or hot starting procedure and the test...
Advanced diesel electronic fuel injection and turbocharging
NASA Astrophysics Data System (ADS)
Beck, N. J.; Barkhimer, R. L.; Steinmeyer, D. C.; Kelly, J. E.
1993-12-01
The program investigated advanced diesel air charging and fuel injection systems to improve specific power, fuel economy, noise, exhaust emissions, and cold startability. The techniques explored included variable fuel injection rate shaping, variable injection timing, full-authority electronic engine control, turbo-compound cooling, regenerative air circulation as a cold start aid, and variable geometry turbocharging. A Servojet electronic fuel injection system was designed and manufactured for the Cummins VTA-903 engine. A special Servojet twin turbocharger exhaust system was also installed. A series of high speed combustion flame photos was taken using the single cylinder optical engine at Michigan Technological University. Various fuel injection rate shapes and nozzle configurations were evaluated. Single-cylinder bench tests were performed to evaluate regenerative inlet air heating techniques as an aid to cold starting. An exhaust-driven axial cooling air fan was manufactured and tested on the VTA-903 engine.
40 CFR 86.1343-88 - Calculations; particulate exhaust emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... cold-start test, grams. (3) PH = Mass particulate measured during the hot-start test, grams. (4) BHP-hr..., grams per test phase. (PH = Pmass for the hot-start test and PC = Pmass for the cold-start test. (2... Exhaust Test Procedures § 86.1343-88 Calculations; particulate exhaust emissions. (a) The final reported...
40 CFR 86.1343-88 - Calculations; particulate exhaust emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... cold-start test, grams. (3) PH = Mass particulate measured during the hot-start test, grams. (4) BHP-hr..., grams per test phase. (PH = Pmass for the hot-start test and PC = Pmass for the cold-start test. (2... Exhaust Test Procedures § 86.1343-88 Calculations; particulate exhaust emissions. (a) The final reported...
Cold start dynamics and temperature sliding observer design of an automotive SOFC APU
NASA Astrophysics Data System (ADS)
Lin, Po-Hsu; Hong, Che-Wun
This paper presents a dynamic model for studying the cold start dynamics and observer design of an auxiliary power unit (APU) for automotive applications. The APU is embedded with a solid oxide fuel cell (SOFC) stack which is a quiet and pollutant-free electric generator; however, it suffers from slow start problem from ambient conditions. The SOFC APU system equips with an after-burner to accelerate the start-up transient in this research. The combustion chamber burns the residual fuel (and air) left from the SOFC to raise the exhaust temperature to preheat the SOFC stack through an energy recovery unit. Since thermal effect is the dominant factor that influences the SOFC transient and steady performance, a nonlinear real-time sliding observer for stack temperature was implemented into the system dynamics to monitor the temperature variation for future controller design. The simulation results show that a 100 W APU system in this research takes about 2 min (in theory) for start-up without considering the thermal limitation of the cell fracture.
NUCLA Circulating Atmospheric Fluidized Bed Demonstration Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keith, Raymond E.; Heller, Thomas J.; Bush, Stuart A.
1991-01-01
This Annual Report on Colorado-Ute Electric Association's NUCLA Circulating Fluidized Bed (CFB) Demonstration Program covers the period from February 1987 through December 1988. The outline for presentation in this report includes a summary of unit operations along with individual sections covering progress in study plan areas that commenced during this reporting period. These include cold-mode shakedown and calibration, plant commercial performance statistics, unit start-up (cold), coal and limestone preparation and handling, ash handling system performance and operating experience, tubular air heater, baghouse operation and performance, materials monitoring, and reliability monitoring. During this reporting period, the coal-mode shakedown and calibration planmore » was completed. (VC)« less
Ozaki, H; Nagai, Y; Tochihara, Y
2001-04-01
We evaluated human physiological responses and the performance of manual tasks during exposure to severe cold (-25 degrees C) at night (0300-0500 hours) and in the afternoon (1500-1700 hours). Thirteen male students wearing standard cold protective clothing occupied a severely cold room (-25 degrees C) for 20 min, and were then transferred to a cool room (10 degrees C) for 20 min. This pattern of exposure was repeated three times, for a total time of exposure to extreme cold of 60 min. The experiments were started either at 1500 hours or 0300 hours and measurements of rectal temperature, skin temperature, blood pressure, performance in a counting task, hand tremor, and subjective responses were made in each condition. At the end of the experiment at night the mean decrease in rectal temperature [0.68 (SEM 0.04) degree C] was significantly greater than that at the end of the experiment in the afternoon [0.55 (SEM 0.08) degree C, P < 0.01]. After the second cold exposure at night the mean increase in diastolic blood pressure [90 (SEM 2.0) mmHg] was significantly greater than that at the end of the second cold exposure in the afternoon [82 (SEM 2.8) mmHg, P < 0.01]. At the end of the second cold exposure at night, mean finger skin temperature [11.8 (SEM 0.8) degrees C] was significantly higher than that at the comparable time in the afternoon [9.0 (SEM 0.7) degrees C, P < 0.01]. Similarly for the toe, mean skin temperature at the start of the second cold exposure at night [25.6 (SEM 1.5) degrees C] was significantly higher than in the afternoon [20.1 (SEM 0.8) degrees C, P < 0.01]. The increased skin temperatures in the periphery resulted in increased heat loss. Since peripheral skin temperatures were highest at night, the subjects noted diminished sensations of thermal cold and pain at that time. Manual dexterity at the end of the first cold exposure at night [mean 83.7 (SEM 3.6) times.min-1] had decreased significantly more than at the end of the first cold exposure in the afternoon [mean 89.4 (SEM 3.5) times.min-1, P < 0.01]. These findings of a lowered rectal temperature and diminished manual dexterity suggest that there is an increased risk of both hypothermia and accidents for those who work at night.
QoS prediction for web services based on user-trust propagation model
NASA Astrophysics Data System (ADS)
Thinh, Le-Van; Tu, Truong-Dinh
2017-10-01
There is an important online role for Web service providers and users; however, the rapidly growing number of service providers and users, it can create some similar functions among web services. This is an exciting area for research, and researchers seek to to propose solutions for the best service to users. Collaborative filtering (CF) algorithms are widely used in recommendation systems, although these are less effective for cold-start users. Recently, some recommender systems have been developed based on social network models, and the results show that social network models have better performance in terms of CF, especially for cold-start users. However, most social network-based recommendations do not consider the user's mood. This is a hidden source of information, and is very useful in improving prediction efficiency. In this paper, we introduce a new model called User-Trust Propagation (UTP). The model uses a combination of trust and the mood of users to predict the QoS value and matrix factorisation (MF), which is used to train the model. The experimental results show that the proposed model gives better accuracy than other models, especially for the cold-start problem.
Hetrick, Robert Eugene; Hilbert, Harold Sean; Parsons, Michael Howard; Stockhausen, William Francis
1997-10-07
A fuel injection system used in the intake air passageway of an internal combustion engine has a strategy for reducing cold start hydrocarbon emissions. The fuel injector has an actuator which allows the fuel spray pattern to be varied from one which is widely dispersed and atomized to one which is only weakly dispersed. A strategy for varying the spray pattern during the engine warm-up period after cold start is disclosed. The strategy increases evaporation within the passageway so that cold start overfuelling and attendant hydrocarbon emissions are reduced.
Armendariz, Alfredo; Leith, David; Boundy, Maryanne; Goodman, Randall; Smith, Les; Carlton, Gary
2003-01-01
Aircraft engines emit an aerosol plume during startup in extremely cold weather that can drift into areas occupied by flightline ground crews. This study tested a personal sampler used to assess exposure to particles in the plume under challenging field conditions. Area and personal samples were taken at two U.S. Air Force (USAF) flightlines during the winter months. Small tube-and-wire electrostatic precipitators (ESPs) were mounted on a stationary stand positioned behind the engines to sample the exhaust. Other ESPs were worn by ground crews to sample breathing zone concentrations. In addition, an aerodynamic particle sizer 3320 (APS) was used to determine the size distribution of the particles. Samples collected with the ESP were solvent extracted and analyzed with gas chromatography-mass spectrometry. Results indicated that the plume consisted of up to 75 mg/m(3) of unburned jet fuel particles. The APS showed that nearly the entire particle mass was respirable, because the plumes had mass median diameters less than 2 micro m. These tests demonstrated that the ESP could be used at cold USAF flightlines to perform exposure assessments to the cold start particles.
Shafer, Scott F.
2002-01-01
The present invention relates to hydraulic systems including hydraulically actuated fuel injectors that have a pilot operated spool valve assembly. One class of hydraulically actuated fuel injectors includes a solenoid driven pilot valve that controls the initiation of the injection event. However, during cold start conditions, hydraulic fluid, typically engine lubricating oil, is particularly viscous and is often difficult to displace through the relatively small drain path that is defined past the pilot valve member. Because the spool valve typically responds slower than expected during cold start due to the difficulty in displacing the relatively viscous oil, accurate start of injection timing can be difficult to achieve. There also exists a greater difficulty in reaching the higher end of the cold operating speed range. Therefore, the present invention utilizes a fluid evacuation valve to aid in displacement of the relatively viscous oil during cold start conditions.
Simulation of Cold Flow in a Truncated Ideal Nozzle with Film Cooling
NASA Technical Reports Server (NTRS)
Braman, Kalen; Ruf, Joseph
2015-01-01
Flow transients during rocket start-up and shut-down can lead to significant side loads on rocket nozzles. The capability to estimate these side loads computationally can streamline the nozzle design process. Towards this goal, the flow in a truncated ideal contour (TIC) nozzle has been simulated for a range of nozzle pressure ratios (NPRs) aimed to match a series of cold flow experiments performed at the NASA MSFC Nozzle Test Facility. These simulations were performed with varying turbulence model choices and with four different versions of the TIC nozzle model geometry, each of which was created with a different simplification to the test article geometry.
Social Collaborative Filtering by Trust.
Yang, Bo; Lei, Yu; Liu, Jiming; Li, Wenjie
2017-08-01
Recommender systems are used to accurately and actively provide users with potentially interesting information or services. Collaborative filtering is a widely adopted approach to recommendation, but sparse data and cold-start users are often barriers to providing high quality recommendations. To address such issues, we propose a novel method that works to improve the performance of collaborative filtering recommendations by integrating sparse rating data given by users and sparse social trust network among these same users. This is a model-based method that adopts matrix factorization technique that maps users into low-dimensional latent feature spaces in terms of their trust relationship, and aims to more accurately reflect the users reciprocal influence on the formation of their own opinions and to learn better preferential patterns of users for high-quality recommendations. We use four large-scale datasets to show that the proposed method performs much better, especially for cold start users, than state-of-the-art recommendation algorithms for social collaborative filtering based on trust.
NASA Astrophysics Data System (ADS)
Heeb, Norbert V.; Forss, Anna-Maria; Saxer, Christian J.; Wilhelm, Patrick
The US urban driving cycle (FTP-75) is widely used to estimate both the emissions under hot engine conditions as well as those associated with the cold start. Applying fast analysis techniques such as chemical ionization mass spectrometry (CI-MS) the warm-up behavior of individual vehicles can be monitored at a time resolution of 1 s. CI-MS has been used to investigate the emissions of methane, benzene and the alkyl benzene class of compounds. The amount of the emissions at cold start influence was deduced from the time-resolved emission data of four gasoline-driven vehicle classes representing the vehicle technology of the last two decades. Overall, the emissions of five EURO-0, 20 EURO-1, 18 EURO-2 and so far of six EURO-3 passenger cars were recorded. The test vehicles were selected from the currently operating Swiss car fleet based on the car sales statistics. The average methane, benzene and alkyl benzene cold start emissions are reported using both, the traditional bag method as well as the regression model. At room temperature a clear reduction of 94%, 81% and 85% was found for the methane, benzene and alkyl benzene cold start emissions from EURO-0 to EURO-3 technology, respectively.
Alcohol cold starting - A theoretical study
NASA Technical Reports Server (NTRS)
Browning, L. H.
1983-01-01
Two theoretical computer models have been developed to study cold starting problems with alcohol fuels. The first model, a droplet fall-out and sling-out model, shows that droplets must be smaller than 50 microns to enter the cylinder under cranking conditions without being slung-out in the intake manifold. The second model, which examines the fate of droplets during the compression process, shows that the heat of compression can be used to vaporize small droplets (less than 50 microns) producing flammable mixtures below freezing ambient temperatures. While droplet size has the greater effect on startability, a very high compression ratio can also aid cold starting.
Effects of cold temperature and ethanol content on VOC ...
Emissions of speciated volatile organic compounds (VOCs), including mobile source air toxics (MSATs), were measured in vehicle exhaust from three light-duty spark ignition vehicles operating on summer and winter grade gasoline (E0) and ethanol blended (E10 and E85) fuels. Vehicle testing was conducted using a three-phase LA92 driving cycle in a temperature-controlled chassis dynamometer at two ambient temperatures (-7 °C and 24 °C). The cold start phase and cold ambient temperature increased VOC and MSAT emissions dramatically by up to several orders of magnitude compared to emissions during other phases and warm ambient temperature testing, respectively. As a result, calculated ozone formation potentials during the cold starts were significantly higher during cold temperature tests by 7 to 21 times the warm temperature values. The use of E85 fuel generally led to substantial reductions in hydrocarbons and increases in oxygenates such as ethanol and acetaldehyde compared to E0 and E10 fuels. However, the VOC emissions from E0 and E10 fuels were not significantly different. Cold temperature effects on cold start MSAT emissions varied by individual MSAT compound, but were consistent over a range of modern spark ignition vehicles. This manuscript communicates APPCD research activities on air toxics VOC emissions from mobile sources from the EPAct dynamometer study. Speciated VOC emissions from light-duty vehicles running on gasoline and ethanol blends at cold tem
Effects of Cold Temperature and Ethanol Content on VOC Emissions from Light-Duty Gasoline Vehicles.
George, Ingrid J; Hays, Michael D; Herrington, Jason S; Preston, William; Snow, Richard; Faircloth, James; George, Barbara Jane; Long, Thomas; Baldauf, Richard W
2015-11-03
Emissions of speciated volatile organic compounds (VOCs), including mobile source air toxics (MSATs), were measured in vehicle exhaust from three light-duty spark ignition vehicles operating on summer and winter grade gasoline (E0) and ethanol blended (E10 and E85) fuels. Vehicle testing was conducted using a three-phase LA92 driving cycle in a temperature-controlled chassis dynamometer at two ambient temperatures (-7 and 24 °C). The cold start driving phase and cold ambient temperature increased VOC and MSAT emissions up to several orders of magnitude compared to emissions during other vehicle operation phases and warm ambient temperature testing, respectively. As a result, calculated ozone formation potentials (OFPs) were 7 to 21 times greater for the cold starts during cold temperature tests than comparable warm temperature tests. The use of E85 fuel generally led to substantial reductions in hydrocarbons and increases in oxygenates such as ethanol and acetaldehyde compared to E0 and E10 fuels. However, at the same ambient temperature, the VOC emissions from the E0 and E10 fuels and OFPs from all fuels were not significantly different. Cold temperature effects on cold start MSAT emissions varied by individual MSAT compound, but were consistent over a range of modern spark ignition vehicles.
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... over the prescribed driving schedule may be performed at test point for the purpose of finding the... make a complete cold start test. Engine startup and operation over the first 505 seconds of the driving... preselectable power settings may be set anytime prior to the beginning of the emission test. (g) The driving...
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... over the prescribed driving schedule may be performed at test point for the purpose of finding the... make a complete cold start test. Engine startup and operation over the first 505 seconds of the driving... preselectable power settings may be set anytime prior to the beginning of the emission test. (g) The driving...
40 CFR 86.235-94 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... over the prescribed driving schedule may be performed at test point for the purpose of finding the... make a complete cold start test. Engine startup and operation over the first 505 seconds of the driving... preselectable power settings may be set anytime prior to the beginning of the emission test. (g) The driving...
NASA Astrophysics Data System (ADS)
Mathis, Urs; Mohr, Martin; Forss, Anna-Maria
Particle measurements were performed in the exhaust of five light-duty vehicles (Euro-3) at +23, -7, and -20 °C ambient temperatures. The characterization included measurements of particle number, active surface area, number size distribution, and mass size distribution. We investigated two port-injection spark-ignition (PISI) vehicles, a direct-injection spark-ignition (DISI) vehicle, a compressed ignition (CI) vehicle with diesel particle filter (DPF), and a CI vehicle without DPF. To minimize sampling effects, particles were directly sampled from the tailpipe with a novel porous tube diluter at controlled sampling parameters. The diluted exhaust was split into two branches to measure either all or only non-volatile particles. Effect of ambient temperature was investigated on particle emission for cold and warmed-up engine. For the gasoline vehicles and the CI vehicle with DPF, the main portion of particle emission was found in the first minutes of the driving cycle at cold engine start. The particle emission of the CI vehicle without DPF was hardly affected by cold engine start. For the PISI vehicles, particle number emissions were superproportionally increased in the diameter size range from 0.1 to 0.3 μm during cold start at low ambient temperature. Based on the particle mass size distribution, the DPF removed smaller particles ( dp<0.5μm) more efficiently than larger particles ( dp>0.5μm). No significant effect of ambient temperature was observed when the engine was warmed up. Peak emission of volatile nanoparticles only took place at specific conditions and was poorly repeatable. Nucleation of particles was predominately observed during or after strong acceleration at high speed and during regeneration of the DPF.
Cold starting of fluorescent lamps - part I: a description of the transient regime
NASA Astrophysics Data System (ADS)
Langer, Reinhard; Garner, Richard; Paul, Irina; Horn, Siegfried; Tidecks, Reinhard
2016-10-01
In this paper we give a proposal for the transient behaviour of a cold-started fluorescent lamp, from the generation of the first conductive channel over the normal and abnormal glow discharge and the glow-to-arc (GTA) transition to the arc discharge in the steady state. Starting from the equilibrium voltage-current characteristics of the lamp and considering recent experimental results a qualitative description of the transient regime is developed, which was so far not available in the literature.
Defining the next generation munitions handler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cassiday, B.K.; Koury, G.J.; Pin, F.G.
1995-07-01
RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop-Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start ofmore » the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.« less
Clements, Julie M.; Casa, Douglas J.; Knight, J. Chad; McClung, Joseph M.; Blake, Alan S.; Meenen, Paula M.; Gilmer, Allison M.; Caldwell, Kellie A.
2002-01-01
Objective: To assess whether ice-water immersion or cold-water immersion is the more effective treatment for rapidly cooling hyperthermic runners. Design and Setting: 17 heat-acclimated highly trained distance runners (age = 28 ± 2 years, height = 180 ± 2 cm, weight = 68.5 ± 2.1 kg, body fat = 11.2 ± 1.3%, training volume = 89 ± 10 km/wk) completed a hilly trail run (approximately 19 km and 86 minutes) in the heat (wet-bulb globe temperature = 27 ± 1°C) at an individually selected “comfortable” pace on 3 occasions 1 week apart. The random, crossover design included (1) distance run, then 12 minutes of ice-water immersion (5.15 ± 0.20°C), (2) distance run, then 12 minutes of cold-water immersion (14.03 ± 0.28°C), or (3) distance run, then 12 minutes of mock immersion (no water, air temperature = 28.88 ± 0.76°C). Measurements: Each subject was immersed from the shoulders to the hip joints for 12 minutes in a tub. Three minutes elapsed between the distance run and the start of immersion. Rectal temperature was recorded at the start of immersion, at each minute of immersion, and 3, 6, 10, and 15 minutes postimmersion. No rehydration occurred during any trial. Results: Length of distance run, time to complete distance run, rectal temperature, and percentage of dehydration after distance run were similar (P > .05) among all trials, as was the wet-bulb globe temperature. No differences (P > .05) for cooling rates were found when comparing ice-water immersion, cold-water immersion, and mock immersion at the start of immersion to 4 minutes, 4 to 8 minutes, and the start of immersion to 8 minutes. Ice-water immersion and cold-water immersion cooling rates were similar (P > .05) to each other and greater (P < .05) than mock immersion at 8 to 12 minutes, the start of immersion to 10 minutes, and the start of immersion to every other time point thereafter. Rectal temperatures were similar (P > .05) between ice-water immersion and cold-water immersion at the completion of immersion and 15 minutes postimmersion, but ice-water immersion rectal temperatures were less (P < .05) than cold-water immersion at 6 and 10 minutes postimmersion. Conclusions: Cooling rates were nearly identical between ice-water immersion and cold-water immersion, while both were 38% more effective in cooling after 12 minutes of immersion than the mock-immersion trial. Given the similarities in cooling rates and rectal temperatures between ice-water immersion and cold-water immersion, either mode of cooling is recommended for treating the hyperthermic individual. PMID:12937427
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Where: Ywm = Weighted mass emissions of each pollutant, i.e., HC, CO, NOX or CO , in grams per vehicle mile. Yct = Mass emissions as calculated from the “transient” phase of the cold start test, in grams... grams per test phase. Ys = Mass emissions as calculated from the “stabilized” phase of the cold start...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Where: Ywm = Weighted mass emissions of each pollutant, i.e., HC, CO, NOX or CO , in grams per vehicle mile. Yct = Mass emissions as calculated from the “transient” phase of the cold start test, in grams... grams per test phase. Ys = Mass emissions as calculated from the “stabilized” phase of the cold start...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Where: Ywm = Weighted mass emissions of each pollutant, i.e., HC, CO, NOX or CO , in grams per vehicle mile. Yct = Mass emissions as calculated from the “transient” phase of the cold start test, in grams... grams per test phase. Ys = Mass emissions as calculated from the “stabilized” phase of the cold start...
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Where: Ywm = Weighted mass emissions of each pollutant, i.e., HC, CO, NOX or CO , in grams per vehicle mile. Yct = Mass emissions as calculated from the “transient” phase of the cold start test, in grams... grams per test phase. Ys = Mass emissions as calculated from the “stabilized” phase of the cold start...
Saliba, Georges; Saleh, Rawad; Zhao, Yunliang; Presto, Albert A; Lambe, Andrew T; Frodin, Bruce; Sardar, Satya; Maldonado, Hector; Maddox, Christine; May, Andrew A; Drozd, Greg T; Goldstein, Allen H; Russell, Lynn M; Hagen, Fabian; Robinson, Allen L
2017-06-06
Recent increases in the Corporate Average Fuel Economy standards have led to widespread adoption of vehicles equipped with gasoline direct-injection (GDI) engines. Changes in engine technologies can alter emissions. To quantify these effects, we measured gas- and particle-phase emissions from 82 light-duty gasoline vehicles recruited from the California in-use fleet tested on a chassis dynamometer using the cold-start unified cycle. The fleet included 15 GDI vehicles, including 8 GDIs certified to the most-stringent emissions standard, superultra-low-emission vehicles (SULEV). We quantified the effects of engine technology, emission certification standards, and cold-start on emissions. For vehicles certified to the same emissions standard, there is no statistical difference of regulated gas-phase pollutant emissions between PFIs and GDIs. However, GDIs had, on average, a factor of 2 higher particulate matter (PM) mass emissions than PFIs due to higher elemental carbon (EC) emissions. SULEV certified GDIs have a factor of 2 lower PM mass emissions than GDIs certified as ultralow-emission vehicles (3.0 ± 1.1 versus 6.3 ± 1.1 mg/mi), suggesting improvements in engine design and calibration. Comprehensive organic speciation revealed no statistically significant differences in the composition of the volatile organic compounds emissions between PFI and GDIs, including benzene, toluene, ethylbenzene, and xylenes (BTEX). Therefore, the secondary organic aerosol and ozone formation potential of the exhaust does not depend on engine technology. Cold-start contributes a larger fraction of the total unified cycle emissions for vehicles meeting more-stringent emission standards. Organic gas emissions were the most sensitive to cold-start compared to the other pollutants tested here. There were no statistically significant differences in the effects of cold-start on GDIs and PFIs. For our test fleet, the measured 14.5% decrease in CO 2 emissions from GDIs was much greater than the potential climate forcing associated with higher black carbon emissions. Thus, switching from PFI to GDI vehicles will likely lead to a reduction in net global warming.
ERIC Educational Resources Information Center
Fraser, Erica L.
2009-01-01
This dissertation starts from the premise that World War II changed Soviet ideas about manhood. The Soviet Union lost twenty-seven million combatants and civilians in World War II--twenty million of whom were men. Delineating, performing, negotiating, and resisting a variety of cultural ideas about manliness shaped Soviet militarism and ideology…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goettler, H.J.; Vidger, L.J.
The effect of exhaust-to-coolant heat exchange on fuel economy and cab heater performance during cold start was studied using a 1981 Ford Granada automobile and a 1977 Buick V-6 engine on a test stand. The ambient soaking temperatures ranged from 35 to -15 degrees Fahrenheit. It was found that fuel used in a 7 minute warm up run of the test stand engine was less by 2.1 to 4.6% when the heat exchanger replaced the muffler in the system. Likewise for the Granada, fuel consumption was less by 2.8 to 3.8% over an in town test route and less bymore » 1.5 to 1.8% on a highway test route, when the heat exchanger replaced the muffler. Similarly, the time required for the coolant at the inlet of the cab heater to reach a temperature of 180 Fahrenheit was 27.5 to 28.8% shorter for the test stand engine, 6.3 to 7.0% shorter for the Granada in town route and 16.6 to 16.9% shorter for the Granada highway route, when the heat exchanger replaced the muffler.« less
Microstructure and texture evolution in cold-rolled and annealed alloy MA-956
NASA Astrophysics Data System (ADS)
Hosoda, Takashi
The microstructural and texture development with thermomechanical processing, performed through a combination of cold-rolling and annealing, in MA-956 plate consisting of a layered and inhomogeneous microstructure was systematically assessed. The alloy contained in mass percent, 20 Cr, 4.8 Al, 0.4 Ti, 0.4 Y2O3, and the balance iron. The starting material was as-hot-rolled plate, 9.7 mm thick. The as-hot-rolled plate was subjected to 40%, 60%, and 80% cold-rolling reduction and subsequently annealed at 1000, 1200, or 1380. Assessment of microstructural and texture developments before and after cold-rolling and annealing was performed using light optical microscopy (LOM), Vickers hardness testing, and electron backscatter diffraction (EBSD). Locally introduced misorientations by cold-rolling in each region were evaluated by Kernel Average Misorientation (KAM) maps. The as-hot-rolled condition contained a layered and inhomogeneous microstructure consisting of thin and coarse elongated grains, and aggregated regions which consisted of fine grains and sub-grains with {100} texture parallel to the longitudinal direction. The microstructure of the 40% cold-rolled condition contained deformation bands, and the 60% and 80% cold-rolled conditions also contained highly deformed regions where the deformation bands were intricately tangled. A predominant orientation of (001) parallel to the rolling direction was developed during cold-rolling, becoming more prominent with increasing reduction. The magnitudes of KAM angles varied through the thickness depending on the initial microstructures. Recrystallization occurred in regions where high KAM angles were dense after annealing and nucleation sites were the aggregation regions, deformation bands, and highly deformed regions. The shape and size of the recrystallized grains varied depending on the nucleation sites.
NASA Astrophysics Data System (ADS)
Mehta, K. K.; Mandal, R. K.; Singh, A. K.
2018-07-01
The high ratio of relative resolved shear stress on a twin to planar slip system results in microstructural latent hardening (some kind of overshooting) by the twin system on the primary slip planes, which leads to development of the {111}-fiber in Ni-16Cr alloy. The development of {111}-fiber starts as early as around 16 pct cold reduction in Ni-16Cr alloy and persists with maximum average intensity ranging from 35 to 40 pct additional deformation, i.e., around 50 pct cold reduction in unidirectional (U) and two-step cross (T)-rolling modes. In between 50 and 68 pct reductions in U and T modes, the fiber becomes unstable and starts disappearing. However, in multistep cross (M) rolling, the {111}-fiber formation starts late, i.e., at around 50 pct reduction, and maintains its stability up to additional deformation ranging from 35 to 40 pct, i.e., around 90 pct cold reduction. Thus, the life of {111}-fiber remains stable only within the range from 35 to 40 pct intermediate deformation during cold rolling of Ni-16Cr alloy irrespective of modes of rolling. However, the start and end of fiber stabilities depend on the modes of deformation by rolling. The maximum average intensity of {111}-fiber that can be attained in Ni-16Cr alloy is around 3.6× random in any of the deformation modes.
NASA Astrophysics Data System (ADS)
Mehta, K. K.; Mandal, R. K.; Singh, A. K.
2018-04-01
The high ratio of relative resolved shear stress on a twin to planar slip system results in microstructural latent hardening (some kind of overshooting) by the twin system on the primary slip planes, which leads to development of the {111}-fiber in Ni-16Cr alloy. The development of {111}-fiber starts as early as around 16 pct cold reduction in Ni-16Cr alloy and persists with maximum average intensity ranging from 35 to 40 pct additional deformation, i.e., around 50 pct cold reduction in unidirectional (U) and two-step cross (T)-rolling modes. In between 50 and 68 pct reductions in U and T modes, the fiber becomes unstable and starts disappearing. However, in multistep cross (M) rolling, the {111}-fiber formation starts late, i.e., at around 50 pct reduction, and maintains its stability up to additional deformation ranging from 35 to 40 pct, i.e., around 90 pct cold reduction. Thus, the life of {111}-fiber remains stable only within the range from 35 to 40 pct intermediate deformation during cold rolling of Ni-16Cr alloy irrespective of modes of rolling. However, the start and end of fiber stabilities depend on the modes of deformation by rolling. The maximum average intensity of {111}-fiber that can be attained in Ni-16Cr alloy is around 3.6× random in any of the deformation modes.
Chen, Ming-biao; Li, Yong-wei; Tan, Yuan-biao; Ma, Min; Wang, Xue-min; Liu, Wen-chang
2015-03-01
At present the study of relation between microstructure, texture and performance of CC 5083 aluminium alloy after cold tolling and recrystallization processes is still finitude. So that the use of the CC 5083 aluminium alloy be influenced. Be cased into electrical furnace, hot up with unlimited speed followed the furnace hot up to different temperature and annealed 2h respectively, and be cased into salt-beth furnace, hot up quickly to different temperature and annealed 30 min respectively for CC 5083 and CC 5182 aluminum alloy after cold roling with 91.5% reduction. The microstructure be watched use metallographic microscope, the texture be inspected by XRD. The start temperature of recrystallization and grain grow up temperature within annealing in the electric furnace of CC 5083 aluminum alloy board is 343 degrees C, and the shap of grain after grow up with long strip (the innovation point ); The start temperature of recrystallization within annealling in the salt bath furnace of CC 5083 is 343 degrees C. The start temperature and end temperature of recrystallization within annealling of CC 5083 and CC 5182 aluminum alloy is 371 degrees C. The grain grow up outstanding of cold rooled CC 5152 aluminum alloy after annealed with 454 degrees C in the electric furnace and salt bath furnace. The start temperature of grain grow up of CC 5083 alluminurn alloy annealed in the electric furnace and salt bath furnace respectively is higher than the start temperature of grain grow up of CC 5182 alluminum alloy annealed in the electric furnace and salt bath furnace respectively. The strat temperature of recrystallization grain grow up is higher than which annealled with other three manner annealing process. The recrystallization temperature of CC 5182 annealed in the salt bath furnace is higher than which annealed in the electric furnace. The recrystallization temperature of the surface layer of CC 5083 and CC 5182 aluminum alloy is higher than the inner layer (the innovation point). There is a difference each other of the structure and the texture of the four manner annealing aluminum alloy (the innovation point). There is a little difference at the recrystallization processes course reflectived by the observe results of structure transform and by the examination results of texture transmission.
ERIC Educational Resources Information Center
Paterson, Thomas G.
1986-01-01
Briefly reviews conventional reasoning about the start of the Cold War. Describes contemporary revisionist views of the Cold War and the reasons they arose. Maintains that American leaders exaggerated the Soviet ideological and military threat, spurring an American arms build-up which ultimately led to the present-day arms race. (JDH)
Genes critical for the induction of cold acclimation in wheat (Triticum aestivum L.)
USDA-ARS?s Scientific Manuscript database
Phenotypic studies have shown that cold acclimation in wheat and its relatives start at different temperatures. To gain insight into the underlying mechanisms that regulate the induction of cold-acclimation process in cereals we compared the expression of genes in winter-habit (winter Norstar and w...
NASA Astrophysics Data System (ADS)
Sorrentino, Marco; Pianese, Cesare
The exploitation of an SOFC-system model to define and test control and energy management strategies is presented. Such a work is motivated by the increasing interest paid to SOFC technology by industries and governments due to its highly appealing potentialities in terms of energy savings, fuel flexibility, cogeneration, low-pollution and low-noise operation. The core part of the model is the SOFC stack, surrounded by a number of auxiliary devices, i.e. air compressor, regulating pressure valves, heat exchangers, pre-reformer and post-burner. Due to the slow thermal dynamics of SOFCs, a set of three lumped-capacity models describes the dynamic response of fuel cell and heat exchangers to any operation change. The dynamic model was used to develop low-level control strategies aimed at guaranteeing targeted performance while keeping stack temperature derivative within safe limits to reduce stack degradation due to thermal stresses. Control strategies for both cold-start and warmed-up operations were implemented by combining feedforward and feedback approaches. Particularly, the main cold-start control action relies on the precise regulation of methane flow towards anode and post-burner via by-pass valves; this strategy is combined with a cathode air-flow adjustment to have a tight control of both stack temperature gradient and warm-up time. Results are presented to show the potentialities of the proposed model-based approach to: (i) serve as a support to control strategies development and (ii) solve the trade-off between fast SOFC cold-start and avoidance of thermal-stress caused damages.
The natural history of community-acquired common colds symptoms assessed over 4-years.
Witek, Theodore J; Ramsey, David L; Carr, Andrew N; Riker, Donald K
2015-03-01
The common cold is the most frequently experienced infection among humans, but limited data exist to characterize the onset, duration, severity and intersection of symptoms in community-acquired colds. A more complete understanding of the symptom frequency and burden in naturally occurring colds is needed. We characterized common cold symptoms from 226 cold episodes experienced by 104 male or female subjects. Subjects were enrolled in the work environment in an attempt to start symptom evaluation (frequency and severity) at the earliest sign of their cold. We also assessed the symptom that had the greatest impact on the subject by asking them to identify their single most bothersome symptom. Symptom reporting started within 24 hours of cold onset for most subjects. Sore throat was a harbinger of the illness but was accompanied by multiple symptoms, including nasal congestion, runny nose and headache. Cough was not usually the most frequent symptom, but was present throughout the cold, becoming most bothersome later in the cold. Nasal congestion, pain (eg, sore throat, headache, muscle pains) or feverishness and secretory symptoms (eg, runny nose, sneezing), and even cough, were simultaneously experienced with high incidence over the first 4 days of illness. The single most bothersome symptom was sore throat on day 1, followed by nasal congestion on days 2-5 and cough on days 6 and 7. There is substantial overlap in the appearance of common cold symptoms over the first several days of the common cold. Nasal congestion, secretory and pain symptoms frequently occur together, with cough being somewhat less prominent, but quite bothersome when present. These data establish the typical symptomatology of a common cold and provide a foundation for the rational treatment of cold symptoms typically experienced by cold sufferers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miers, Scott A.; Blough, Jason R.
The objective of this study was to evaluate the effects of E15 on current and legacy snowmobile engines and vehicles that could occur due to misfueling by the vehicle owner. Three test scenarios were conducted to evaluate the impact of E15, including cold-start performance and emissions, on-snow vehicle driveability, and laboratory exhaust emissions over the useful life of the engine. The eightengines tested represent current and legacy product that may exhibit sensitivity to increased ethanol blended in gasoline. Because a limited number of snowmobile engines were evaluated for this test program, the results are not statistically significant. However, the broadmore » range of engine and mixture preparation technologies, combined with the various test scenarios provide preliminaryinformation to assess potential issues with E15 use in snowmobiles. Cold-start tests were performed at -6.7 degrees C (20 degrees F), -17.8 degrees C (0 degrees F), and -28.9 degrees C (-20 degrees F). The evaluation included time to start or number of pulls to start, engine speed, exhaust gas temperature, and start-up engine emissions concentrations. Statistically significant differences instarting times were not observed for most vehicles. Snowmobile driveability was analyzed using a subjective evaluation on a controlled test course. The drivers could not easily discern which fuel the snowmobiles were using during the subjective evaluation. Durability tests were conducted to measure the emissions and performance of the snowmobiles over the useful life of the vehicles (5,000miles). There were no fuel-related engine failures on E0 or E15. Carbon monoxide emissions were generally reduced by E15 relative to E0, by from 10% to 35%. Occasional misfueling of snowmobiles with E15 is not likely to cause noticeable or immediate problems for consumers. E15 is not approved for snowmobile use, and observations made during this study support the U.S. Environmental ProtectionAgency's decision to not approve E15 for snowmobiles.« less
Simulation of Cold Flow in a Truncated Ideal Nozzle with Film Cooling
NASA Technical Reports Server (NTRS)
Braman, K. E.; Ruf, J. H.
2015-01-01
Flow transients during rocket start-up and shut-down can lead to significant side loads on rocket nozzles. The capability to estimate these side loads computationally can streamline the nozzle design process. Towards this goal, the flow in a truncated ideal contour (TIC) nozzle has been simulated using RANS and URANS for a range of nozzle pressure ratios (NPRs) aimed to match a series of cold flow experiments performed at the NASA MSFC Nozzle Test Facility. These simulations were performed with varying turbulence model choices and for four approximations of the supersonic film injection geometry, each of which was created with a different simplification of the test article geometry. The results show that although a reasonable match to experiment can be obtained with varying levels of geometric fidelity, the modeling choices made do not fully represent the physics of flow separation in a TIC nozzle with film cooling.
Puértolas, B; Navlani-García, M; García, T; Navarro, M V; Lozano-Castelló, D; Cazorla-Amorós, D
2014-08-30
A key target to reduce current hydrocarbon emissions from vehicular exhaust is to improve their abatement under cold-start conditions. Herein, we demonstrate the potential of factorial analysis to design a highly efficient catalytic trap. The impact of the synthesis conditions on the preparation of copper-loaded ZSM-5 is clearly revealed by XRD, N2 sorption, FTIR, NH3-TPD, SEM and TEM. A high concentration of copper nitrate precursor in the synthesis improves the removal of hydrocarbons, providing both strong adsorption sites for hydrocarbon retention at low temperature and copper oxide nanoparticles for full hydrocarbon catalytic combustion at high temperature. The use of copper acetate precursor leads to a more homogeneous dispersion of copper oxide nanoparticles also providing enough catalytic sites for the total oxidation of hydrocarbons released from the adsorption sites, although lower copper loadings are achieved. Thus, synthesis conditions leading to high copper loadings jointly with highly dispersed copper oxide nanoparticles would result in an exceptional catalytic trap able to reach superior hydrocarbon abatement under highly demanding operational conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
Imaging strategies for the study of gas turbine spark ignition
NASA Astrophysics Data System (ADS)
Gord, James R.; Tyler, Charles; Grinstead, Keith D., Jr.; Fiechtner, Gregory J.; Cochran, Michael J.; Frus, John R.
1999-10-01
Spark-ignition systems play a critical role in the performance of essentially all gas turbine engines. These devices are responsible for initiating the combustion process that sustains engine operation. Demanding applications such as cold start and high-altitude relight require continued enhancement of ignition systems. To characterize advanced ignition systems, we have developed a number of laser-based diagnostic techniques configured for ultrafast imaging of spark parameters including emission, density, temperature, and species concentration. These diagnostics have been designed to exploit an ultrafast- framing charge-coupled-device (CCD) camera and high- repetition-rate laser sources including mode-locked Ti:sapphire oscillators and regenerative amplifiers. Spontaneous-emission and laser-shlieren measurements have been accomplished with this instrumentation and the result applied to the study of a novel Unison Industries spark igniter that shows great promise for improved cold-start and high-altitude-relight capability as compared to that of igniters currently in use throughout military and commercial fleets. Phase-locked and ultrafast real-time imaging strategies are explored, and details of the imaging instrumentation, particularly the CCD camera and laser sources, are discussed.
2017-02-16
APEX-04, or Advanced Plant EXperiments-04, is being prepared in a cold room in the Kennedy Space Center Processing Facility for SpaceX-10. The petri plates are wrapped in black cloth and kept cold (+4 degrees Celsius) to prevent them from germinating prior to the experiment start on station. Dr. Anna Lisa Paul of the University of Florida is the principal investigator for APEX-04. Apex-04 is an experiment involving Arabidopsis in petri plates inside the Veggie facility aboard the International Space Station. Since Arabidopsis is the genetic model of the plant world, it is a perfect sample organism for performing genetic studies in spaceflight. The experiment is the result of a grant from NASA’s Space Life and Physical Sciences division.
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... approximately 7.5 miles (12.1 kilometers) and a hot start drive of approximately 3.6 miles (5.8 kilometers). (b... and hot start test. The cold start test is divided into two periods. The first period, representing..., consists of the remainder of the driving schedule, including engine shutdown. The hot start test is...
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... approximately 7.5 miles (12.1 kilometers) and a hot start drive of approximately 3.6 miles (5.8 kilometers). (b... and hot start test. The cold start test is divided into two periods. The first period, representing..., consists of the remainder of the driving schedule, including engine shutdown. The hot start test is...
40 CFR 86.237-94 - Dynamometer test run, gaseous emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... approximately 7.5 miles (12.1 kilometers) and a hot start drive of approximately 3.6 miles (5.8 kilometers). (b... and hot start test. The cold start test is divided into two periods. The first period, representing..., consists of the remainder of the driving schedule, including engine shutdown. The hot start test is...
40 CFR 86.236-94 - Engine starting and restarting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Engine starting and restarting. 86.236... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.236-94 Engine starting and...
40 CFR 86.236-94 - Engine starting and restarting.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Engine starting and restarting. 86.236... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.236-94 Engine starting and...
40 CFR 86.236-94 - Engine starting and restarting.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Engine starting and restarting. 86.236... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.236-94 Engine starting and...
40 CFR 86.236-94 - Engine starting and restarting.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Engine starting and restarting. 86.236... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.236-94 Engine starting and...
1982-01-01
that has been exposed to cold has had serious cold injuries. Ten percent of our wounded casualties in both World War 1I (90,000) and Korea (9,000...have been damaged which compromises blood flow. Late complications of cold/wet injuries Include ulceration and chronic Infections. Although rare in...painful during rewarming usually starting as a tingling or burning pain followed by throbbing, swelling, and increased redness throughout the area
Laser-Free Cold-Atom Gymnastics
NASA Astrophysics Data System (ADS)
Gould, Harvey; Feinberg, Benedict; Munger, Charles T., Jr.; Nishimura, Hiroshi
2017-01-01
We have performed beam transport simulations on ultra cold (2 μK) and cold (130 μK) neutral Cs atoms in the F = M = + 4 (magnetic weak-field seeking) ground state. We use inhomogeneous magnetic fields to focus and accelerate the atoms. Acceleration of neutral atoms by an inhomogeneous magnetic field was demonstrated by Stern and Gerlach in 1922. In the simulations, a two mm diameter cloud of atoms is released to fall under gravity. A magnetic coil focuses the falling atoms. After falling 41 cm, the atoms are reflected in the magnetic fringe field of a solenoid. They return to their starting height, about 0.7 s later, having passed a second time through the focusing coil. The simulations show that > 98 % of ultra cold Cs atoms and > 70 % of cold Cs atoms will survive at least 15 round trips (assuming perfect vacuum). More than 100 simulations were run to optimize coil currents and focusing coil diameter and height. Simulations also show that atoms can be launched into a fountain. An experimental apparatus to test the simulations, is being constructed. This technique may find application in atomic fountain clocks, interferometers, and gravitometers, and may be adaptable for use in microgravity. It may also work with Bose-Einstein condensates of paramagnetic atoms.
Improving first case start times using Lean in an academic medical center.
Deldar, Romina; Soleimani, Tahereh; Harmon, Carol; Stevens, Larry H; Sood, Rajiv; Tholpady, Sunil S; Chu, Michael W
2017-06-01
Lean is a process improvement strategy that can improve efficiency of the perioperative process. The purpose of this study was to identify etiologies of late surgery start times, implement Lean interventions, and analyze their effects. A retrospective review of all first-start surgery cases was performed. Lean was implemented in May 2015, and cases 7 months before and after implementation were analyzed. A total of 4,492 first-start cases were included; 2,181 were pre-Lean and 2,311 were post-Lean. The post-Lean group had significantly higher on-time starts than the pre-Lean group (69.0% vs 57.0%, P < .01). The most common delay etiology was surgeon-related for both groups. Delayed post-Lean cases were significantly less likely to be due to preoperative assessment (14.9% vs 9.9%, P < .01) and more likely due to patient-related (16.5% vs 22.3%, P < .01) or chaplain (1.8% vs 4.0%, P < .01) factors. Delayed starts occurred more often on snowy and cold days, and less often on didactic days (P < .01). Modifying preoperative tasks using Lean methods can improve operating room efficiency and increase on-time starts. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gao, Xin; Chen, Min; Snyder, G. Jeffrey; Andreasen, Søren Juhl; Kær, Søren Knudsen
2013-07-01
To better manage the magnitude and direction of the heat flux in an exchanger-based methanol evaporator of a fuel cell system, thermoelectric (TE) modules can be deployed as TE heat flux regulators (TERs). The performance of the TE-integrated evaporator is strongly influenced by its heat exchange structure. The structure transfers the fuel cell exhaust heat to the evaporation chamber to evaporate the methanol, where TE modules are installed in between to facilitate the heat regulation. In this work, firstly, a numerical study is conducted to determine the working currents and working modes of the TERs under the system working condition fluctuations and during the system cold start. A three-dimensional evaporator model is generated in ANSYS FLUENT® by combining a compact TE model with various heat exchange structure geometries. The compact TE model can dramatically improve the computational efficiency, and uses a different material property acquisition method based on module manufacturers' datasheets. Secondly, a simulation study is carried out on the novel evaporator to minimize its thermal resistance and to assess the evaporator pressure drop. The factors studied include the type of fins in the heat exchange structure, the thickness of the fins, the axial conduction penalty, etc. Results show that the TE-integrated evaporator can work more efficiently and smoothly during both load fluctuations and system cold start, offering superior performance.
Cold-start and chemical characterization of emissions from mobile sources in Mexico.
Schifter, I; Díaz, L; Rodríguez, R
2010-10-01
In this work tailpipe and evaporative emissions from a set of normal and high emitter vehicle models, year 2006-2008 (low mileage) certified when new to meet the Tier 1 emission standard, were characterized for criteria pollutants (carbon monoxide, nitrogen oxides and hydrocarbons), and a suite of unregulated emissions including aliphatic and aromatic aldehydes, monocyclic aromatic compounds, 1,3 butadiene, n-hexane and acrolein. Data were obtained under the three different driving conditions of the United States Federal Test Procedure, FTP-75 cycle. High emissions of both regulated and unregulated pollutants were observed in the cold-start phase of the driving cycle for low mileage Tier 1 normal and high emitters engines. Data were compared with results obtained for a set of MY > 1992-2005 that included vehicles with no catalytic converters, Tier 0 and MY 2000-5 Tier 1 emission standard with high mileage. The calculated average cold-start emissions for normal emitters in grams are 0.93, 8.21 and 1.06 for NMHC CO, and NOx, respectively for Tier 1 low mileage vehicles. The reductions in emissions for Tier 1 normal emitters are 76%, 56% and 56% for NMHC, CO and NOx, respectively, but 58%, 30% and 25% for the high emitters. Differences in emission can be ascribed to the mileage accumulation more than technological improvements. Cold-start emissions account in the USA roughly 10% of emissions from gasoline-powered vehicles. In Mexico the fractions are likely to be higher because one must account also for the contribution of Tier 0 and the running exhausts emissions of vehicles with no catalytic converters.
Impacts of typhoon megi (2010) on the South China Sea
NASA Astrophysics Data System (ADS)
Ko, Dong Shan; Chao, Shenn-Yu; Wu, Chun-Chieh; Lin, I.-I.
2014-07-01
In October 2010, typhoon Megi induced a profound cold wake of size 800 km by 500 km with sea surface temperature cooling of 8°C in the South China Sea (SCS). More interestingly, the cold wake shifted from the often rightward bias to both sides of the typhoon track and moved to left in a few days. Using satellite data, in situ measurements and numerical modeling based on the East Asian Seas Nowcast/Forecast System (EASNFS), we performed detailed investigations. To obtain realistic typhoon-strength atmospheric forcing, the EASNFS applied typhoon-resolving Weather Research and Forecasting (WRF) model wind field blended with global weather forecast winds from the U.S. Navy Operational Global Atmospheric Prediction System (NOGAPS). In addition to the already known impacts from the slow typhoon translation speed and shallow pre-exiting ocean thermocline, we found the importance of the unique geographical setting of the SCS and the NE monsoon. As the event happened in late October, NE monsoon already started and contributed to the southwestward ambient surface current. Together with the topographicβ effect, the cold wake shifted westward to the left of Megi's track. It was also found that Megi expelled waters away from the SCS and manifested as a gush of internal Kelvin wave exporting waters through the Luzon Strait. The consequential sea level depression lasted and presented a favorable condition for cold dome development. Fission of the north-south elongated cold dome resulted afterward and produced two cold eddies that dissipated slowly thereafter.
Ice Slurry Ingestion and Physiological Strain During Exercise in Non-Compensable Heat Stress.
Ng, Jason; Wingo, Jonathan E; Bishop, Phillip A; Casey, Jason C; Aldrich, Elizabeth K
2018-05-01
Precooling with ice slurry ingestion attenuates the increase in rectal temperature (Tre) during subsequent running and cycling. It remains unclear how this cooling method affects physiological strain during work while wearing protective garments. This study investigated the effect of ice slurry ingestion on physiological strain during work in hot conditions while wearing firefighter protective clothing. In three counterbalanced trials, eight men (mean ± SD; age = 21 ± 2 yr, height = 179.5 ± 3.5 cm, mass = 79.1 ± 4.1 kg, body fat = 11.4 ± 3.7%) wore firefighter protective clothing and walked (4 km · h-1, 12% incline, ∼7 METs) for 30 min in hot conditions (35°C, 40% RH). Every 2.5 min, subjects ingested 1.25 g · kg-1 (relative total: 15 g · kg-1, absolute total: 1186.7 ± 61.3 g) of a tepid (22.4 ± 1.7°C), cold (7.1 ± 1.5°C), or ice slurry (-1.3 ± 0.2°C) beverage. Heart rates (HR) were lower with ice slurry ingestion compared to both fluid trials starting 5 min into exercise (tepid = 158 ± 14, cold = 157 ± 11, ice slurry = 146 ± 13 bpm) and persisting for the remainder of the bout (min 30: tepid = 196 ± 10, cold = 192 ± 10, ice slurry = 181 ± 13 bpm). Tre was lower with ice slurry ingestion compared to cold and tepid trials (min 5: tepid = 37.17 ± 0.38, cold = 37.17 ± 0.39, ice slurry = 37.05 ± 0.43°C; min 30: tepid = 38.15 ± 0.29, cold = 38.31 ± 0.36, ice slurry = 37.95 ± 0.32°C). The physiological strain index (PSI) was lower with ice slurry ingestion compared to fluid trials starting at min 5 (tepid = 3.8 ± 0.7, cold = 3.8 ± 0.6, ice slurry = 3.0 ± 0.5) and remained lower throughout exercise (min 30: tepid = 8.2 ± 0.6, cold = 8.3 ± 0.9, ice slurry = 6.9 ± 1.2). A large quantity of ice slurry ingested under non-compensable heat stress conditions mitigated physiological strain during exercise by blunting the rise in heart rate and rectal temperature.Ng J, Wingo JE, Bishop PA, Casey JC, Aldrich EK. Ice slurry ingestion and physiological strain during exercise in non-compensable heat stress. Aerosp Med Hum Perform. 2018; 89(5):434-441.
Memory access in shared virtual memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berrendorf, R.
1992-01-01
Shared virtual memory (SVM) is a virtual memory layer with a single address space on top of a distributed real memory on parallel computers. We examine the behavior and performance of SVM running a parallel program with medium-grained, loop-level parallelism on top of it. A simulator for the underlying parallel architecture can be used to examine the behavior of SVM more deeply. The influence of several parameters, such as the number of processors, page size, cold or warm start, and restricted page replication, is studied.
Memory access in shared virtual memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berrendorf, R.
1992-09-01
Shared virtual memory (SVM) is a virtual memory layer with a single address space on top of a distributed real memory on parallel computers. We examine the behavior and performance of SVM running a parallel program with medium-grained, loop-level parallelism on top of it. A simulator for the underlying parallel architecture can be used to examine the behavior of SVM more deeply. The influence of several parameters, such as the number of processors, page size, cold or warm start, and restricted page replication, is studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearce, T.C.; Waters, M.H.L.
Measurements have been made of the fuel consumption of a petrol and a diesel car when starting from cold. The cars were the 1.1 liter petrol VW Golf and the 1.5 liter diesel version, which have the same passenger accommodation and nearly identical road performance. It was found that the diesel car used less fuel in the warm-up period than the petrol, both when being driven at constant speed on a test track and with the engine idling and the car stationary. (Copyright (c) Crown Copyright 1980.)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gardiner, D; Mallory, R; Todesco, M
This report describes an experimental investigation of the potential for an enhanced ignition system to lower the cold-start emissions of a light-duty vehicle engine using fuel ethanol (commonly referred to as E85). Plasma jet ignition and conventional inductive ignition were compared for a General Motors 4-cylinder, alcohol-compatible engine. Emission and combustion stability measurements were made over a range of air/fuel ratios and spark timing settings using a steady-state, cold-idle experimental technique in which the engine coolant was maintained at 25 C to simulate cold-running conditions. These tests were aimed at identifying the degree to which calibration strategies such as mixturemore » enleanment and retarded spark timing could lower engine-out hydrocarbon emissions and raise exhaust temperatures, as well as determining how such calibration changes would affect the combustion stability of the engine (as quantified by the coefficient of variation, or COV, of indicated mean effective pressure calculated from successive cylinder pressure measurements). 44 refs., 39 figs.« less
Cold Start of a Radiator Equipped with Titanium-Water Heat Pipes
NASA Technical Reports Server (NTRS)
Jaworske, Donald A.; Sanzi, James L.; Siamidis, John
2008-01-01
Radiator panels utilizing titanium-water heat pipes are being considered for lunar applications. A traditional sandwich structure is envisioned where heat pipes are embedded between two high thermal conductivity face sheets. The heat pipe evaporators are to be thermally connected to the heat source through one or more manifolds containing coolant. Initial radiator operation on the lunar surface would likely follow a cold soak where the water in the heat pipes is purposely frozen. To achieve heat pipe operation, it will be necessary to thaw the heat pipes. One option is to allow the sunlight impinging on the surface at sunrise to achieve this goal. Testing was conducted in a thermal vacuum chamber to simulate the lunar sunrise and additional modeling was conducted to identify steady-state and transient response. It was found that sunlight impinging on the radiator surface at sunrise was insufficient to solely achieve the goal of thawing the water in the heat pipes. However, starting from a frozen condition was accomplished successfully by applying power to the evaporators. Start up in this fashion was demonstrated without evaporator dryout. Concern is raised over thawing thermosyphons, vertical heat pipes operating in a gravity field, with no wick in the condenser section. This paper presents the results of the simulated cold start study and identifies future work to support radiator panels equipped with titanium-water heat pipes.
The effect of time of day on cold water ingestion by high-level swimmers in a tropical climate.
Hue, Olivier; Monjo, Roland; Lazzaro, Marc; Baillot, Michelle; Hellard, Philippe; Marlin, Laurent; Jean-Etienne, A
2013-07-01
The authors tested the effect of cold water ingestion during high-intensity training in the morning vs the evening on both core temperature (TC) and thermal perceptions of internationally ranked long-distance swimmers during a training period in a tropical climate. Nine internationally ranked long-distance swimmers (5 men and 4 women) performed 4 randomized training sessions (2 in the evening and 2 in the morning) with 2 randomized beverages with different temperatures for 3 consecutive days. After a standardized warm-up of 1000 m, the subjects performed a standardized training session that consisted of 10 x 100 m (start every 1'20″) at a fixed velocity. The swimmers were then followed for the next 3000 m of the training schedule. Heart rate (HR) was continuously monitored during the 10 x 100 m, whereas TC, thermal comfort, and thermal sensation (TS) were measured before and after each 1000-m session. Before and after each 1000 m, the swimmers were asked to drink 190 mL of neutral (26.5 ± 2.5°C) or cold (1.3 ± 0.3°C) water packaged in standardized bottles. Results demonstrated that cold water ingestion induced a significant effect on TC, with a pronounced decrease in the evening, resulting in significantly lower mean TC and lower mean delta TC in evening cold (EC) than in evening neutral (EN), concomitant with significantly lower TS in EC than in EN and a significant effect on exercise HR. Moreover, although TC increased significantly with time in MN, MC, and EN, TC was stabilized during exercise in EC. To conclude, we demonstrate that a cold beverage had a significant effect on TC, TS, and HR during training in high-level swimmers in a tropical climate, especially during evening training.
Hybrid employment recommendation algorithm based on Spark
NASA Astrophysics Data System (ADS)
Li, Zuoquan; Lin, Yubei; Zhang, Xingming
2017-08-01
Aiming at the real-time application of collaborative filtering employment recommendation algorithm (CF), a clustering collaborative filtering recommendation algorithm (CCF) is developed, which applies hierarchical clustering to CF and narrows the query range of neighbour items. In addition, to solve the cold-start problem of content-based recommendation algorithm (CB), a content-based algorithm with users’ information (CBUI) is introduced for job recommendation. Furthermore, a hybrid recommendation algorithm (HRA) which combines CCF and CBUI algorithms is proposed, and implemented on Spark platform. The experimental results show that HRA can overcome the problems of cold start and data sparsity, and achieve good recommendation accuracy and scalability for employment recommendation.
Marketing E-Commerce by Social media using Product Recommendations and user Embedding
NASA Astrophysics Data System (ADS)
Ramalingam, V. V.; Pandian, A.; Masilamani, Kirthiga
2018-04-01
MarketingE-CommercebySodal media is the best way to improve marketing and business widely.The major issues faced with E-commerce and Social media interfacing is cold- start cross-site problem. The cold-start problem occurs at a situation when user is not having the history of purchase records.For the user who does not have a history of purchase records, we have introduced a method of finding the users’ interested product without knowing any of the demographic information of the user. The product is recommended on basesof visits i.e., the item which is most likely to be visited by the users occur in the hit list. This product is rated at the top position for the users to purchase. The e-commerce with social media sites uses the strategy of user embedding and product recommendations. The product recommendations are achieved by incorporating LatentDirichlet Allocation(LDA), Re Ranking and Collaborative Filtering algorithms. The proposed framework can enhance the recommendation system by embedding products and users. This shows the potential of solving cold-start cross-site problem across the e-commerce and social media sites and enhances the marketing strategy.
Cold starting of fluorescent lamps - part II: experiments on glow times and electrode damaging
NASA Astrophysics Data System (ADS)
Langer, Reinhard; Paul, Irina; Hilscher, Achim; Horn, Siegfried; Tidecks, Reinhard
2017-01-01
In the present work we present experiments on cold start and the resulting electrode damaging (reducing lamp life) of AC driven fluorescent lamps. The crucial parameter is the glow time, determined from time resolved measurements of lamp voltage and current. The relation between the energy consumed during glow phase and the glow time is studied. It turns out that there is no common threshold of energy until the glow-to-arc transition takes place, but strong energy input into the lamp yields short glow times. The transient behaviour from the glow to the arc regime is investigated and the stable operation points of the arc discharge are determined, yielding an arc discharge voltage-current characteristics of the lamp type investigated. The electrode damage is investigated as a function of the open source voltage and the ballast resistance. Subsequent cold starts lead to an increase of the glow time due to electrode damaging, i.e., the electrode damage accumulates. Different regeneration procedures and their effectiveness are compared. Regeneration burning turns out to be more effective than heating up the electrode. A criterion for avoiding high electrode damage is obtained, indicating that the average power during glow time should exceed 20 W.
Glove and mitten protection in extreme cold weather: an Antarctic study.
Iserson, Kenneth V
2016-01-01
Background Myths, misconceptions and a general lack of information surround the use of gloves and mittens in extreme cold environments. Objective This study assessed how well an assortment of gloves and mittens performed in a very cold environment. Methods A convenience sample of gloves and mittens were tested in Antarctica during the winter of 2016 using a calibrated thermometer (range: -148°F to +158°F/-100°C to +70°C) three times over a 0.5-mile distance (~20 minutes). A small sensor on a 10-foot-long cable was taped to the radial surface of the distal small finger on the non-dominant hand. The tested clothing was donned over the probe, the maximum temperature inside the glove/mitten was established near a building exit (ambient temperature approximately 54°F/12°C), and the building was exited, initiating the test. The hand was kept immobile during the test. Some non-heated gloves were tested with chemical heat warmers placed over the volar or dorsal wrist. Results The highest starting (96°F/36°C) and ending (82°F/28°C) temperatures were with electrically heated gloves. The lowest starting temperature was with electrically heated gloves with the power off (63°F/17°C). Non-heated gloves with an inserted chemical hand warmer had the lowest minimum temperature (33°F/1°C). Maximum temperatures for gloves/mittens did not correlate well with their minimum temperature. Conclusions Coverings that maintained finger temperatures within a comfortable and safe range (at or above 59°F/15°C) included the heated gloves and mittens (including some with the power off) and mittens with liners. Mittens without liners (shell) generally performed better than unheated gloves. Better results generally paralleled the item's cost. Inserting chemical heat warmers at the wrist increased heat loss, possibly through the exposed area around the warmer.
Glove and mitten protection in extreme cold weather: an Antarctic study.
Iserson, Kenneth V
2016-01-01
Myths, misconceptions and a general lack of information surround the use of gloves and mittens in extreme cold environments. This study assessed how well an assortment of gloves and mittens performed in a very cold environment. A convenience sample of gloves and mittens were tested in Antarctica during the winter of 2016 using a calibrated thermometer (range: -148°F to +158°F/-100°C to +70°C) three times over a 0.5-mile distance (~20 minutes). A small sensor on a 10-foot-long cable was taped to the radial surface of the distal small finger on the non-dominant hand. The tested clothing was donned over the probe, the maximum temperature inside the glove/mitten was established near a building exit (ambient temperature approximately 54°F/12°C), and the building was exited, initiating the test. The hand was kept immobile during the test. Some non-heated gloves were tested with chemical heat warmers placed over the volar or dorsal wrist. The highest starting (96°F/36°C) and ending (82°F/28°C) temperatures were with electrically heated gloves. The lowest starting temperature was with electrically heated gloves with the power off (63°F/17°C). Non-heated gloves with an inserted chemical hand warmer had the lowest minimum temperature (33°F/1°C). Maximum temperatures for gloves/mittens did not correlate well with their minimum temperature. Coverings that maintained finger temperatures within a comfortable and safe range (at or above 59°F/15°C) included the heated gloves and mittens (including some with the power off) and mittens with liners. Mittens without liners (shell) generally performed better than unheated gloves. Better results generally paralleled the item's cost. Inserting chemical heat warmers at the wrist increased heat loss, possibly through the exposed area around the warmer.
Wu, Jun; Jiang, Chengsheng; Liu, Zhen; Houston, Douglas; Jaimes, Guillermo; McConnell, Rob
2010-11-23
People's time-location patterns are important in air pollution exposure assessment because pollution levels may vary considerably by location. A growing number of studies are using global positioning systems (GPS) to track people's time-location patterns. Many portable GPS units that archive location are commercially available at a cost that makes their use feasible for epidemiological studies. We evaluated the performance of five portable GPS data loggers and two GPS cell phones by examining positional accuracy in typical locations (indoor, outdoor, in-vehicle) and factors that influence satellite reception (building material, building type), acquisition time (cold and warm start), battery life, and adequacy of memory for data storage. We examined stationary locations (eg, indoor, outdoor) and mobile environments (eg, walking, traveling by vehicle or bus) and compared GPS locations to highly-resolved US Geological Survey (USGS) and Digital Orthophoto Quarter Quadrangle (DOQQ) maps. The battery life of our tested instruments ranged from <9 hours to 48 hours. The acquisition of location time after startup ranged from a few seconds to >20 minutes and varied significantly by building structure type and by cold or warm start. No GPS device was found to have consistently superior performance with regard to spatial accuracy and signal loss. At fixed outdoor locations, 65%-95% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices. At fixed indoor locations, 50%-80% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices except one. Most of the GPS devices performed well during commuting on a freeway, with >80% of points within 10-m of the DOQQ route, but the performance was significantly impacted by surrounding structures on surface streets in highly urbanized areas. All the tested GPS devices had limitations, but we identified several devices which showed promising performance for tracking subjects' time location patterns in epidemiological studies.
Wu, Jun; Jiang, Chengsheng; Liu, Zhen; Houston, Douglas; Jaimes, Guillermo; McConnell, Rob
2010-01-01
Background: People’s time-location patterns are important in air pollution exposure assessment because pollution levels may vary considerably by location. A growing number of studies are using global positioning systems (GPS) to track people’s time-location patterns. Many portable GPS units that archive location are commercially available at a cost that makes their use feasible for epidemiological studies. Methods: We evaluated the performance of five portable GPS data loggers and two GPS cell phones by examining positional accuracy in typical locations (indoor, outdoor, in-vehicle) and factors that influence satellite reception (building material, building type), acquisition time (cold and warm start), battery life, and adequacy of memory for data storage. We examined stationary locations (eg, indoor, outdoor) and mobile environments (eg, walking, traveling by vehicle or bus) and compared GPS locations to highly-resolved US Geological Survey (USGS) and Digital Orthophoto Quarter Quadrangle (DOQQ) maps. Results: The battery life of our tested instruments ranged from <9 hours to 48 hours. The acquisition of location time after startup ranged from a few seconds to >20 minutes and varied significantly by building structure type and by cold or warm start. No GPS device was found to have consistently superior performance with regard to spatial accuracy and signal loss. At fixed outdoor locations, 65%–95% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices. At fixed indoor locations, 50%–80% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices except one. Most of the GPS devices performed well during commuting on a freeway, with >80% of points within 10-m of the DOQQ route, but the performance was significantly impacted by surrounding structures on surface streets in highly urbanized areas. Conclusions: All the tested GPS devices had limitations, but we identified several devices which showed promising performance for tracking subjects’ time location patterns in epidemiological studies. PMID:21151593
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Di; Zankl, Maria; DeMarco, John J.
Purpose: Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of ''hot'' spots or ''cold'' spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans. Methods: Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCTmore » scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene. Dose to fetus was also estimated using four pregnant female models based on CT images of the pregnant patients. Whole-body scans were simulated using 120 kVp, 300 mAs, both 28.8 and 40 mm nominal collimations, and pitch values of 1.5, 1.0, and 0.75 under a wide range of start angles (0 deg. - 340 deg. in 20 deg. increments). The relationship between tube start angle and organ dose was examined for each organ, and the potential dose reduction was calculated. Results: Some organs exhibit a strong dose variation, depending on the tube start angle. For small peripheral organs (e.g., the eye lenses of the Baby phantom at pitch 1.5 with 40 mm collimation), the minimum dose can be 41% lower than the maximum dose, depending on the tube start angle. In general, larger dose reductions occur for smaller peripheral organs in smaller patients when wider collimation is used. Pitch 1.5 and pitch 0.75 have different mechanisms of dose reduction. For pitch 1.5 scans, the dose is usually lowest when the tube start angle is such that the x-ray tube is posterior to the patient when it passes the longitudinal location of the organ. For pitch 0.75 scans, the dose is lowest when the tube start angle is such that the x-ray tube is anterior to the patient when it passes the longitudinal location of the organ. Conclusions: Helical MDCT scanning at pitch 1.5 and pitch 0.75 results in ''cold spots'' and ''hot spots'' that are created both at surface and in-depth locations within patients. For organs that have a relatively small longitudinal extent, dose can vary considerably with different start angles. While current MDCT systems do not provide the user with the ability to control the tube start angle, these results indicate that in these specific situations (pitch 1.5 or pitch 0.75, small organs and especially small patients), there could be significant dose savings to organs if that functionality would be provided.« less
Alkali metal pool boiler life tests for a 25 kWe advanced Stirling conversion system
NASA Technical Reports Server (NTRS)
Anderson, W. G.; Rosenfeld, J. H.; Noble, J.
1991-01-01
The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding an alkali metal pool boiler heat transport system to supply heat more uniformly to the heater head tubes. One issue with liquid metal pool boilers is unstable boiling. Stable boiling is obtained with an enhanced boiling surface containing nucleation sites that promote continuous boiling. Over longer time periods, it is possible that the boiling behavior of the system will change. An 800-h life test was conducted to verify that pool boiling with the chosen fluid/surface combination remains stable as the system ages. The apparatus uses NaK boiling on a - 100 + 140 stainless steel sintered porous layer, with the addition of a small amount of xenon. Pool boiling remained stable to the end of life test. The pool boiler life test included a total of 82 cold starts, to simulate startup each morning, and 60 warm restarts, to simulate cloud cover transients. The behavior of the cold and warm starts showed no significant changes during the life test. In the experiments, the fluid/surface combination provided stable, high-performance boiling at the operating temperature of 700 C. Based on these experiments, a pool boiler was designed for a full-scale 25-kWe Stirling system.
Analysis of boron dilution in a four-loop PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, J.G.; Sha, W.T.
1995-03-01
Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four-loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plant ismore » at hot standby and the reactor coolant system has been heated to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated and a sensitivity study is performed to assess the accuracy of the numerical modeling of the geometry of the reactor coolant system.« less
Cold acclimation and cognitive performance: A review.
Jones, Douglas M; Bailey, Stephen P; Roelands, Bart; Buono, Michael J; Meeusen, Romain
2017-12-01
Athletes, occupational workers, and military personnel experience cold temperatures through cold air exposure or cold water immersion, both of which impair cognitive performance. Prior work has shown that neurophysiological pathways may be sensitive to the effects of temperature acclimation and, therefore, cold acclimation may be a potential strategy to attenuate cold-induced cognitive impairments for populations that are frequently exposed to cold environments. This review provides an overview of studies that examine repeated cold stress, cold acclimation, and measurements of cognitive performance to determine whether or not cold acclimation provides beneficial protection against cold-induced cognitive performance decrements. Studies included in this review assessed cognitive measures of reaction time, attention, logical reasoning, information processing, and memory. Repeated cold stress, with or without evidence of cold acclimation, appears to offer no added benefit of improving cognitive performance. However, research in this area is greatly lacking and, therefore, it is difficult to draw any definitive conclusions regarding the use of cold acclimation to improve cognitive performance during subsequent cold exposures. Given the current state of minimal knowledge on this topic, athletes, occupational workers, and military commands looking to specifically enhance cognitive performance in cold environments would likely not be advised to spend the time and effort required to become acclimated to cold. However, as more knowledge becomes available in this area, recommendations may change. Copyright © 2017 Elsevier B.V. All rights reserved.
Demonstration and evaluation of gas turbine transit buses
NASA Technical Reports Server (NTRS)
1983-01-01
The Gas Turbine Transit Bus Demonstration Program was designed to demonstrate and evaluate the operation of gas turbine engines in transit coaches in revenue service compared with diesel powered coaches. The main objective of the program was to accelerate development and commercialization of automotive gas turbines. The benefits from the installation of this engine in a transit coach were expected to be reduced weight, cleaner exhaust emissions, lower noise levels, reduced engine vibration and maintenance requirements, improved reliability and vehicle performance, greater engine braking capability, and superior cold weather starting. Four RTS-II advanced design transit coaches were converted to gas turbine power using engines and transmissions. Development, acceptance, performance and systems tests were performed on the coaches prior to the revenue service demonstration.
Duţu, S; Jienescu, Z; Bîscă, N; Bistriceanu, G
1989-01-01
Of the patients with chronic obstructive pulmonary disease (COLD) and severe obstructive syndrome, 39 whose age was under 40 were selected. In 23 of them, the anamnesis revealed bronchopulmonary affections in childhood, that required admission into the hospital (19 were non-smokers). Of the rest of 16 patients, 14 were hard smokers that started to smoke before the age of 14. The functional picture was severely modified, similarly to that of the COLD patients in the 6th decade of life. This suggests that the degradation process started in the childhood, and that the chronic respiratory diseases and/or smoking at an early age had an important role.
ERIC Educational Resources Information Center
Bjork, Janna
2005-01-01
Warm days, cold nights, melting snow-signs winter is waning and spring is nearing. Though winter may just be getting started in some areas, it's always fun to appreciate the good things about winter, including the special time at the end of winter in New England known as "sugaring time." The sap starts flowing in the sugar maples, and…
Zhao, Yunliang; Lambe, Andrew T; Saleh, Rawad; Saliba, Georges; Robinson, Allen L
2018-02-06
Secondary organic aerosol (SOA) formation from dilute exhaust from 16 gasoline vehicles was investigated using a potential aerosol mass (PAM) oxidation flow reactor during chassis dynamometer testing using the cold-start unified cycle (UC). Ten vehicles were equipped with gasoline direct injection engines (GDI vehicles) and six with port fuel injection engines (PFI vehicles) certified to a wide range of emissions standards. We measured similar SOA production from GDI and PFI vehicles certified to the same emissions standard; less SOA production from vehicles certified to stricter emissions standards; and, after accounting for differences in gas-particle partitioning, similar effective SOA yields across different engine technologies and certification standards. Therefore the ongoing, dramatic shift from PFI to GDI vehicles in the United States should not alter the contribution of gasoline vehicles to ambient SOA and the natural replacement of older vehicles with newer ones certified to stricter emissions standards should reduce atmospheric SOA levels. Compared to hot operations, cold-start exhaust had lower effective SOA yields, but still contributed more SOA overall because of substantially higher organic gas emissions. We demonstrate that the PAM reactor can be used as a screening tool for vehicle SOA production by carefully accounting for the effects of the large variations in emission rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-04-01
This article describes a system developed for rapid light-off of underbody catalysts that has shown potential to meet Euro Stage III emissions targets and to be more cost-effective than some alternatives. Future emissions legislation will require SI engine aftertreatment systems to approach full operating efficiency within the first few seconds after starting to reduce the high total-emissions fraction currently contributed by the cold phase of driving. A reduction of cold-start emissions during Phase 1 (Euro) or Bag 1 (FTP), which in many cases can be as much as 80% of the total for the cycle, has been achieved by electricalmore » heating of the catalytic converter. But electrically heated catalyst (EHC) systems require high currents (100--200 A) to heat the metallic substrate to light-off temperatures over the first 15--20 seconds. Other viable approaches to reducing cold-start emissions include use of a fuel-powered burner upstream of the catalyst. However, as with EHC, the complexity of parts and the introduction of raw fuel into the exhaust system make this device unsatisfactory. Still another approach, an exhaust gas ignition (EGI) system, was first demonstrated in 1991. The operation of a system developed by engineers at Ford Motor Co., Ltd., Cambustion Ltd., and Tickford Ltd. is described here.« less
On a Wing and a Prayer: A Holistic Vision for Airpower in Small Wars
2017-05-25
Clausewitz, 156. 7 The MPU Model first and foremost starts with the political nature of war, appropriately defining its character and shape... starts with the beginning of the Cold War and the fight against Communism following World War II, with initial strategic guidance from President...defeat and withdrawal in 1954, a period of gradually increasing US involvement and violence began in and around Vietnam, initially starting with the
Vermeulen, C J; Sørensen, P; Kirilova Gagalova, K; Loeschcke, V
2013-09-01
In sexually reproducing species, increased homozygosity often causes a decline in fitness, called inbreeding depression. Recently, researchers started describing the functional genomic changes that occur during inbreeding, both in benign conditions and under environmental stress. To further this aim, we have performed a genome-wide gene expression study of inbreeding depression, manifesting as cold sensitivity and conditional lethality. Our focus was to describe general patterns of gene expression during inbreeding depression and to identify specific processes affected in our line. There was a clear difference in gene expression between the stressful restrictive environment and the benign permissive environment in both the affected inbred line and the inbred control line. We noted a strong inbreeding-by-environment interaction, whereby virtually all transcriptional differences between lines were found in the restrictive environment. Functional annotation showed enrichment of transcripts coding for serine proteases and their inhibitors (serpins and BPTI/Kunitz family), which indicates activation of the innate immune response. These genes have previously been shown to respond transcriptionally to cold stress, suggesting the conditional lethal effect is associated with an exaggerated cold stress response. The set of differentially expressed genes significantly overlapped with those found in three other studies of inbreeding depression, demonstrating that it is possible to detect a common signature across different genetic backgrounds. © 2013 The Authors. Journal of Evolutionary Biology © 2013 European Society For Evolutionary Biology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Y.; Besant, R.W.; Chen, H.
1999-07-01
An experimental investigation of frost growth on a flat, cold surface supplied by subfreezing, turbulent, humid, parallel flow of air is presented. The operating conditions are typical of many commercial freezers. A test loop was constructed to perform the tests, and the frost height, frost mass concentration, and cold surface heat flux were measured using specially designed and calibrated instrumentation. Twenty tests were done for steady operating conditions, each starting with no initial frost accumulation, and were run for two to six hours giving 480 data samples. Measured results show that the frost characteristics differ significantly with frost growth datamore » taken previously for room temperature airflow. Depending on the temperature of the cold plate and the relative humidity of the subfreezing supply air, the frost could appear to be either smooth or rough. Smooth frost, which occurred at warmer plate temperatures and lower supply air relative humidities, gave rise to frost growth that was much thinner and denser than that for the rough, thick, low-density frost. Frost growth characteristics are correlated as a function of five independent variables (time, distance from the leading edge, cold plate temperature ratio, humidity ratio, and Reynolds number). These correlations are presented separately for the full data set, the rough frost data, and the smooth frost data.« less
The Combined Effect of Cold and Moisture on Manual Performance.
Ray, Matthew; Sanli, Elizabeth; Brown, Robert; Ennis, Kerri Ann; Carnahan, Heather
2018-02-01
Objective The aim of this study was to investigate the combined effect of cold and moisture on manual performance and tactile sensitivity. Background People working in the ocean environment often perform manual work in cold and wet conditions. Although the independent effects of cold and moisture on hand function are known, their combined effect has not been investigated. Method Participants completed sensory (Touch-Test, two-point discrimination) and motor (Purdue Pegboard, Grooved Pegboard, reef knot untying) tests in the following conditions: dry hand, wet hand, cold hand, and cold and wet hand. Results For the Purdue Pegboard and knot untying tasks, the greatest decrement in performance was observed in the cold-and-wet-hand condition, whereas the decrements seen in the cold-hand and wet-hand conditions were similar. In the Grooved Pegboard task, the performance decrements exhibited in the cold-and-wet-hand condition and the cold-hand condition were similar, whereas no decrement was observed in the wet-hand condition. Tactile sensitivity was reduced in the cold conditions for the Touch-Test but not the two-point discrimination test. The combined effect of cold and moisture led to the largest performance decrements except when intrinsic object properties helped with grasp maintenance. The independent effects of cold and moisture on manual performance were comparable. Application Tools and equipment for use in the cold ocean environment should be designed to minimize the effects of cold and moisture on manual performance by including object properties that enhance grasp maintenance and minimize the fine-dexterity requirements.
Differential expression and emerging functions of non-coding RNAs in cold adaptation.
Frigault, Jacques J; Morin, Mathieu D; Morin, Pier Jr
2017-01-01
Several species undergo substantial physiological and biochemical changes to confront the harsh conditions associated with winter. Small mammalian hibernators and cold-hardy insects are examples of natural models of cold adaptation that have been amply explored. While the molecular picture associated with cold adaptation has started to become clearer in recent years, notably through the use of high-throughput experimental approaches, the underlying cold-associated functions attributed to several non-coding RNAs, including microRNAs (miRNAs) and long non-coding RNAs (lncRNAs), remain to be better characterized. Nevertheless, key pioneering work has provided clues on the likely relevance of these molecules in cold adaptation. With an emphasis on mammalian hibernation and insect cold hardiness, this work first reviews various molecular changes documented so far in these processes. The cascades leading to miRNA and lncRNA production as well as the mechanisms of action of these non-coding RNAs are subsequently described. Finally, we present examples of differentially expressed non-coding RNAs in models of cold adaptation and elaborate on the potential significance of this modulation with respect to low-temperature adaptation.
NASA Astrophysics Data System (ADS)
Gonçalves, Cátia; Alves, Célia; Fernandes, Ana Patrícia; Monteiro, Cristina; Tarelho, Luís; Evtyugina, Margarita; Pio, Casimiro
2011-09-01
The aim of this study is the further characterisation of PM 2.5 emissions from the residential wood combustion of common woods grown in Portugal. This new research extends to eight the number of biomass fuels studied and tries to understand the differences that the burning appliance (fireplace versus woodstove) and the combustion temperature (cold and hot start) have on emissions. Pinus pinaster (Maritime pine), Eucalyptus globulus (eucalypt), Quercus suber (cork oak), Acacia longifolia (Golden wattle), Quercus faginea (Portuguese oak), Olea europea (Olive), Quercus ilex rotundifolia (Holm oak) and briquettes produced from forest biomass waste were used in the combustion tests. Determinations included fine particle emission factors, carbonaceous content (OC and EC) by a thermal-optical transmission technique and detailed identification and quantification of organic compounds by gas chromatography-mass spectrometry. Fine particle emission factors from the woodstove were lower than those from the fireplace. For both combustion appliances, the OC/EC ratio was higher in "cold start" tests (1.56 ± 0.95 for woodstove and 2.03 ± 1.34 for fireplace). These "cold start" OC/EC values were, respectively, for the woodstove and the fireplace, 51% and 69% higher than those obtained in "hot start" experiments. The chromatographically resolved organics included n-alkanes, n-alkenes, PAHs, n-alkanals, ketones, n-alkanols, terpenoids, triterpenoids, phenolic compounds, phytosterols, alcohols, n-alkanoic acids, n-di-acids, unsaturated acids and alkyl esters of acids. The smoke emission rate and composition varied widely depending on fuel type, burning appliance and combustion temperature.
Qualification of CASMO5 / SIMULATE-3K against the SPERT-III E-core cold start-up experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grandi, G.; Moberg, L.
SIMULATE-3K is a three-dimensional kinetic code applicable to LWR Reactivity Initiated Accidents. S3K has been used to calculate several international recognized benchmarks. However, the feedback models in the benchmark exercises are different from the feedback models that SIMULATE-3K uses for LWR reactors. For this reason, it is worth comparing the SIMULATE-3K capabilities for Reactivity Initiated Accidents against kinetic experiments. The Special Power Excursion Reactor Test III was a pressurized-water, nuclear-research facility constructed to analyze the reactor kinetic behavior under initial conditions similar to those of commercial LWRs. The SPERT III E-core resembles a PWR in terms of fuel type, moderator,more » coolant flow rate, and system pressure. The initial test conditions (power, core flow, system pressure, core inlet temperature) are representative of cold start-up, hot start-up, hot standby, and hot full power. The qualification of S3K against the SPERT III E-core measurements is an ongoing work at Studsvik. In this paper, the results for the 30 cold start-up tests are presented. The results show good agreement with the experiments for the reactivity initiated accident main parameters: peak power, energy release and compensated reactivity. Predicted and measured peak powers differ at most by 13%. Measured and predicted reactivity compensations at the time of the peak power differ less than 0.01 $. Predicted and measured energy release differ at most by 13%. All differences are within the experimental uncertainty. (authors)« less
NASA Astrophysics Data System (ADS)
Takeda, Takeshi; Maruyama, Yu; Watanabe, Tadashi; Nakamura, Hideo
Experiments simulating PWR intermediate-break loss-of-coolant accidents (IBLOCAs) with 17% break at hot leg or cold leg were conducted in OECD/NEA ROSA-2 Project using the Large Scale Test Facility (LSTF). In the hot leg IBLOCA test, core uncovery started simultaneously with liquid level drop in crossover leg downflow-side before loop seal clearing (LSC) induced by steam condensation on accumulator coolant injected into cold leg. Water remained on upper core plate in upper plenum due to counter-current flow limiting (CCFL) because of significant upward steam flow from the core. In the cold leg IBLOCA test, core dryout took place due to rapid liquid level drop in the core before LSC. Liquid was accumulated in upper plenum, steam generator (SG) U-tube upflow-side and SG inlet plenum before the LSC due to CCFL by high velocity vapor flow, causing enhanced decrease in the core liquid level. The RELAP5/MOD3.2.1.2 post-test analyses of the two LSTF experiments were performed employing critical flow model in the code with a discharge coefficient of 1.0. In the hot leg IBLOCA case, cladding surface temperature of simulated fuel rods was underpredicted due to overprediction of core liquid level after the core uncovery. In the cold leg IBLOCA case, the cladding surface temperature was underpredicted too due to later core uncovery than in the experiment. These may suggest that the code has remaining problems in proper prediction of primary coolant distribution.
The Temporary Environment - Cold Regions Habitability
1976-10-01
studied: Arny. Air Force and FAA. Mobi/e hrduutei unkta Any industria ! unit that requires travel in the cold weather utilizes Army or civilian equipment ...vironmnts studied andc mecn in succeeding sctic.nis proceeds to a much fitter analysis . &nalyses start with prolic %,omparisuns of action patterns and...fornali/e cinviromnmienltal analysis below the le:vel ol’the behavior setting. l ie does specify smaller units such as cvosetties. syninnorphs. and
The War on Cancer: Cold Spring Harbor Laboratory Is Fighting the Good Fight.
Mertz, Leslie
2017-01-01
Located on the north shore of Long Island in New York, Cold Spring Harbor Laboratory (Figure 1) started out with a marine biology emphasis at the end of the 19th century, but it soon established itself as a prominent cancer research facility. That strong emphasis on cancer work continues today as this private, not-for-profit research institution enters its 127th year (Figure 2).
Advanced integrated life support system update
NASA Technical Reports Server (NTRS)
Whitley, Phillip E.
1994-01-01
The Advanced Integrated Life Support System Program (AILSS) is an advanced development effort to integrate the life support and protection requirements using the U.S. Navy's fighter/attack mission as a starting point. The goal of AILSS is to optimally mate protection from altitude, acceleration, chemical/biological agent, thermal environment (hot, cold, and cold water immersion) stress as well as mission enhancement through improved restraint, night vision, and head-mounted reticules and displays to ensure mission capability. The primary emphasis to date has been to establish garment design requirements and tradeoffs for protection. Here the garment and the human interface are treated as a system. Twelve state-off-the-art concepts from government and industry were evaluated for design versus performance. On the basis of a combination of centrifuge, thermal manikin data, thermal modeling, and mobility studies, some key design parameters have been determined. Future efforts will concentrate on the integration of protection through garment design and the use of a single layer, multiple function concept to streamline the garment system.
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Geng, Steven M.; Pearson, J. Boise; Godfroy, Thomas J.
2010-01-01
As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors was modified to operate with a NaK liquid metal pumped loop for thermal energy input. This was the first-ever attempt at powering a free-piston Stirling engine with a pumped liquid metal heat source and is a major FSP project milestone towards demonstrating technical feasibility. The tests included performance mapping the convertors over various hot and cold-end temperatures, piston amplitudes and NaK flow rates; and transient test conditions to simulate various start-up and fault scenarios. Performance maps of the convertors generated using the pumped NaK loop for thermal input show increases in power output over those measured during baseline testing using electric heating. Transient testing showed that the Stirling convertors can be successfully started in a variety of different scenarios and that the convertors can recover from a variety of fault scenarios.
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Geng, Steven M.; Pearson, J. Boise; Godfroy, Thomas J.
2010-01-01
As a step towards development of Stirling power conversion for potential use in Fission Surface Power (FSP) systems, a pair of commercially available 1 kW class free-piston Stirling convertors was modified to operate with a NaK liquid metal pumped loop for thermal energy input. This was the first-ever attempt at powering a free-piston Stirling engine with a pumped liquid metal heat source and is a major FSP project milestone towards demonstrating technical feasibility. The tests included performance mapping the convertors over various hot and cold-end temperatures, piston amplitudes and NaK flow rates; and transient test conditions to simulate various start-up and fault scenarios. Performance maps of the convertors generated using the pumped NaK loop for thermal input show increases in power output over those measured during baseline testing using electric heating. Transient testing showed that the Stirling convertors can be successfully started in a variety of different scenarios and that the convertors can recover from a variety of fault scenarios.
Yarahmadi, Sajad; Mohammadi, Nooredin; Ardalan, Arash; Najafizadeh, Hassan; Gholami, Mohammad
2018-05-01
Chest tube removal is an extremely painful procedure and patients may not respond well to palliative therapies. This study aimed to examine the effect of cold and music therapy individually, as well as a combination of these interventions on reducing pain following chest tube removal. A factorial randomized-controlled clinical trial was performed on 180 patients who underwent cardiac surgery. Patients were randomized into four groups of 45. Group A used ice packs for 20 minutes prior to chest tube removal. Group B was assigned to listen to music for a total length of 30 minutes which started 15 minutes prior to chest tube removal. Group C received a combination of both interventions; and Group D received no interventions. Pain intensity was measured in each group every 15 minutes for a total of 3 readings. Analysis of variance, Tukey and Bonferroni post hoc tests, as well as repeated measures ANOVA were employed for data analysis. Cold therapy and combined method intervention effectively reduced the pain caused by chest tube removal (P < 0.001). Additionally, there were no statistically significant difference in pain intensity scores between groups at 15 minutes following chest tube removal (P = 0.07). Cold and music therapy can be used by nursing staff in clinical practice as a combined approach to provide effective pain control following chest tube removal. Copyright © 2018 Elsevier Ltd. All rights reserved.
Extended Durability Testing of an External Fuel Processor for a Solid Oxide Fuel Cell (SOFC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mark Perna; Anant Upadhyayula; Mark Scotto
2012-11-05
Durability testing was performed on an external fuel processor (EFP) for a solid oxide fuel cell (SOFC) power plant. The EFP enables the SOFC to reach high system efficiency (electrical efficiency up to 60%) using pipeline natural gas and eliminates the need for large quantities of bottled gases. LG Fuel Cell Systems Inc. (formerly known as Rolls-Royce Fuel Cell Systems (US) Inc.) (LGFCS) is developing natural gas-fired SOFC power plants for stationary power applications. These power plants will greatly benefit the public by reducing the cost of electricity while reducing the amount of gaseous emissions of carbon dioxide, sulfur oxides,more » and nitrogen oxides compared to conventional power plants. The EFP uses pipeline natural gas and air to provide all the gas streams required by the SOFC power plant; specifically those needed for start-up, normal operation, and shutdown. It includes a natural gas desulfurizer, a synthesis-gas generator and a start-gas generator. The research in this project demonstrated that the EFP could meet its performance and durability targets. The data generated helped assess the impact of long-term operation on system performance and system hardware. The research also showed the negative impact of ambient weather (both hot and cold conditions) on system operation and performance.« less
Structural assessment of a Space Station solar dynamic heat receiver thermal energy storage canister
NASA Technical Reports Server (NTRS)
Tong, M. T.; Kerslake, T. W.; Thompson, R. L.
1988-01-01
This paper assesses the structural performance of a Space Station thermal energy storage (TES) canister subject to orbital solar flux variation and engine cold start-up operating conditions. The impact of working fluid temperature and salt-void distribution on the canister structure are assessed. Both analytical and experimental studies were conducted to determine the temperature distribution of the canister. Subsequent finite-element structural analyses of the canister were performed using both analytically and experimentally obtained temperatures. The Arrhenius creep law was incorporated into the procedure, using secondary creep data for the canister material, Haynes-188 alloy. The predicted cyclic creep strain accumulations at the hot spot were used to assess the structural performance of the canister. In addition, the structural performance of the canister based on the analytically-determined temperature was compared with that based on the experimentally-measured temperature data.
Structural assessment of a space station solar dynamic heat receiver thermal energy storage canister
NASA Technical Reports Server (NTRS)
Thompson, R. L.; Kerslake, T. W.; Tong, M. T.
1988-01-01
The structural performance of a space station thermal energy storage (TES) canister subject to orbital solar flux variation and engine cold start up operating conditions was assessed. The impact of working fluid temperature and salt-void distribution on the canister structure are assessed. Both analytical and experimental studies were conducted to determine the temperature distribution of the canister. Subsequent finite element structural analyses of the canister were performed using both analytically and experimentally obtained temperatures. The Arrhenius creep law was incorporated into the procedure, using secondary creep data for the canister material, Haynes 188 alloy. The predicted cyclic creep strain accumulations at the hot spot were used to assess the structural performance of the canister. In addition, the structural performance of the canister based on the analytically determined temperature was compared with that based on the experimentally measured temperature data.
Karademir, Aykan; Korucu, M Kemal
2013-07-01
A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3-4 times higher than those observed in the normal operation. Especially lower combustion temperatures in the short start-ups may cause high PCDD/F concentrations in the raw flue gas. Assessment of combustion temperatures and Furans/Dioxins values indicated that surface-catalyzed de novo synthesis was the dominant pathway in the formation of PCDD/Fs in the combustion units. PCDD/F removal efficiencies of Air Pollution Control Devices suggested that formation by de novo synthesis existed in ESP also when in operation, leading to increase of gaseous phase PCDD/Fs in ESP Particle-bound PCDD/Fs were removed mainly by ESP and WS, while gaseous phase PCDD/Fs were removed by WS, and more efficiently by AC filter. This paper evaluates PCDD/F emissions and removal performances of APCDs (ESP, wet scrubbers, and activated carbon) during two start-up periods in an incinerator. The main implications are the following: (1) start-up periods increase PCDD/F emissions up to 2-3 times in the incinerator; (2) low combustion temperatures in start-ups cause high PCDD/F emissions in raw gas; (3) formation of PCDD/Fs by de novo synthesis occurs in ESP; (4) AC is efficient in removing gaseous PCDD/Fs, but may increase particle-bound ones; and (5) scrubbers remove both gaseous and particle-bound PCDD/Fs efficiently.
24 CFR 3280.609 - Water distribution systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and temperature relief valve installed for this purpose shall have the temperature sensing element...) Size of branch. Start at the most remote outlet on any branch of the hot or cold water piping and...
NASA Astrophysics Data System (ADS)
Wohlfahrt, Georg; Cremonese, Edoardo; Hammerle, Albin; Hörtnagl, Lukas; Galvagno, Marta; Gianelle, Damiano; Marcolla, Barbara; Cella, Umberto Morra
2013-12-01
is well established that warming leads to longer growing seasons in seasonally cold ecosystems. Whether this goes along with an increase in the net ecosystem carbon dioxide (CO2) uptake is much more controversial. We studied the effects of warming on the start of the carbon uptake period (CUP) of three mountain grasslands situated along an elevational gradient in the Alps. To this end, we used a simple empirical model of the net ecosystem CO2 exchange, calibrated, and forced with multiyear empirical data from each site. We show that reductions in the quantity and duration of daylight associated with earlier snowmelts were responsible for diminishing returns, in terms of carbon gain, from longer growing seasons caused by reductions in daytime photosynthetic uptake and increases in nighttime losses of CO2. This effect was less pronounced at high, compared to low, elevations, where the start of the CUP occurred closer to the summer solstice when changes in day length and incident radiation are minimal.
Wohlfahrt, Georg; Cremonese, Edoardo; Hammerle, Albin; Hörtnagl, Lukas; Galvagno, Marta; Gianelle, Damiano; Marcolla, Barbara; di Cella, Umberto Morra
2013-12-16
It is well established that warming leads to longer growing seasons in seasonally cold ecosystems. Whether this goes along with an increase in the net ecosystem carbon dioxide (CO 2 ) uptake is much more controversial. We studied the effects of warming on the start of the carbon uptake period (CUP) of three mountain grasslands situated along an elevational gradient in the Alps. To this end we used a simple empirical model of the net ecosystem CO 2 exchange, calibrated and forced with multi-year empirical data from each site. We show that reductions in the quantity and duration of daylight associated with earlier snowmelts were responsible for diminishing returns, in terms of carbon gain, from longer growing seasons caused by reductions in daytime photosynthetic uptake and increases in nighttime losses of CO 2 . This effect was less pronounced at high, compared to low, elevations, where the start of the CUP occurred closer to the summer solstice when changes in day length and incident radiation are minimal.
A facility for testing 10 to 100-kWe space power reactors
NASA Astrophysics Data System (ADS)
Carlson, William F.; Bitten, Ernest J.
1993-01-01
This paper describes an existing facility that could be used in a cost-effective manner to test space power reactors in the 10 to 100-kWe range before launch. The facility has been designed to conduct full power tests of 100-kWe SP-100 reactor systems and already has the structural features that would be required for lower power testing. The paper describes a reasonable scenario starting with the acceptance at the test site of the unfueled reactor assembly and the separately shipped nuclear fuel. After fueling the reactor and installing it in the facility, cold critical tests are performed, and the reactor is then shipped to the launch site. The availability of this facility represents a cost-effective means of performing the required prelaunch test program.
Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Baxter, Van D.; Abdelaziz, Omar
2017-03-01
This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.
Liquid nitrogen historical and current usage of the central helium liquefier at SNS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neustadt, Thomas S.; Kim, Sang-Ho; Howell, Matthew P.
The main cryogenic system for the Spallation Neutron Source (SNS) is comprised of a 4-K cold box, a 2-K cold box, six warm compressors, and ancillary support equipment. This system has been cold and operating with little disruption since 2005. Design and operation of liquid nitrogen (LN2) supplied from a single 20,000-gallon supply Dewar will be discussed. LN2 used to precool the 4-K cold box heat exchanger started to increase around 2011. LN2 Consumption during 2012 and 2013 was almost double the nominal usage rate. Studies of this data, plant parameter changes to respond to this information, and current interpretationsmore » are detailed in this paper. The usage rate of LN2 returned to normal in late 2013 and remained there until recent additional changes. Future study plans to understand potential causes of this including contamination migration within the 4-K cold box will also be addressed.« less
Mauger, Florence; Kernaleguen, Magali; Lallemand, Céline; Kristensen, Vessela N; Deleuze, Jean-François; Tost, Jörg
2018-05-01
The detection of specific DNA methylation patterns bears great promise as biomarker for personalized management of cancer patients. Co-amplification at lower denaturation temperature-PCR (COLD-PCR) assays are sensitive methods, but have previously only been able to analyze loss of DNA methylation. Enhanced (E)-ice-COLD-PCR reactions starting from 2 ng of bisulfite-converted DNA were developed to analyze methylation patterns in two promoters with locked nucleic acid (LNA) probes blocking amplification of unmethylated CpGs. The enrichment of methylated molecules was compared to quantitative (q)PCR and quantified using serial dilutions. E-ice-COLD-PCR allowed the multiplexed enrichment and quantification of methylated DNA. Assays were validated in primary breast cancer specimens and circulating cell-free DNA from cancer patients. E-ice-COLD-PCR could prove a useful tool in the context of DNA methylation analysis for personalized medicine.
Ambient Temperature, Fuel Economy, Emissions, and Trip Length
DOT National Transportation Integrated Search
1979-08-01
This report examines the relationship among automotive fuel economy, ambient temperature, cold-start trip length, and drive-train component temperatures of four 1977 vehicles. Fuel economy, exhaust emission, and drive-train temperatures were measured...
Klimek, Ludger; Schumacher, Helmut; Schütt, Tanja; Gräter, Heidemarie; Mueck, Tobias; Michel, Martin C
2017-02-01
The aim of this study was to explore factors affecting efficacy of treatment of common cold symptoms with an over-the-counter ibuprofen/pseudoephedrine combination product. Data from an anonymous survey among 1770 pharmacy customers purchasing the combination product for treatment of own common cold symptoms underwent post-hoc descriptive analysis. Scores of symptoms typically responsive to ibuprofen (headache, pharyngeal pain, joint pain and fever), typically responsive to pseudoephedrine (congested nose, congested sinus and runny nose), considered non-specific (sneezing, fatigue, dry cough, cough with expectoration) and comprising all 11 symptoms were analysed. Multiple regression analysis was applied to explore factors associated with greater reduction in symptom intensity or greater probability of experiencing a symptom reduction of at least 50%. After intake of first dose of medication, typically ibuprofen-sensitive, pseudoephedrine-responsive, non-specific and total symptoms were reduced by 60.0%, 46.3%, 45.4% and 52.8%, respectively. A symptom reduction of at least 50% was reported by 73.6%, 55.1%, 50.9% and 61.6% of participants, respectively. A high baseline score was associated with greater reductions in symptom scores but smaller probability of achieving an improvement of at least 50%. Across both multiple regression approaches, two tablets at first dosing were more effective than one and (except for ibuprofen-sensitive symptoms) starting treatment later than day 2 of the cold was generally less effective. Efficacy of an ibuprofen/pseudoephedrine combination in the treatment of common cold symptoms was dose-dependent and greatest when treatment started within the first 2 days after onset of symptoms. © 2016 The Authors. International Journal of Clinical Practice Published by John Wiley & Sons Ltd.
Edwards, Andrew M; Crowther, Robert G; Morton, R Hugh; Polman, Remco C
2011-02-01
The study examined whether or not acute exposure to unfamiliar hot or cold conditions impairs performance of highly skilled coordinative activities and whether prior physical self-efficacy beliefs were associated with task completion. Nineteen volunteers completed both Guitar Hero and Archery activities as a test battery using the Nintendo Wii console in cold (2 degrees C), neutral (20 degrees C), and hot (38 degrees C) conditions. Participants all completed physical self-efficacy questionnaires following experimental familiarization. Performances of both Guitar Hero and Archery significantly decreased in the cold compared with the neutral condition. The cold trial was also perceived as the condition requiring both greater concentration and effort. There was no association between performance and physical self-efficacy. Performance of these coordinative tasks was compromised by acute (nonhypothermic) exposure to cold; the most likely explanation is that the cold condition presented a greater challenge to attentional processes as a form of environmental distraction.
Bocian, Aleksandra; Zwierzykowski, Zbigniew; Rapacz, Marcin; Koczyk, Grzegorz; Ciesiołka, Danuta; Kosmala, Arkadiusz
2015-11-01
Abiotic stresses, including low temperature, can significantly reduce plant yielding. The knowledge on the molecular basis of stress tolerance could help to improve its level in species of relatively high importance to agriculture. Unfortunately, the complex research performed so far mainly on model species and also, to some extent, on cereals does not fully cover the demands of other agricultural plants of temperate climate, including forage grasses. Two Lolium perenne (perennial ryegrass) genotypes with contrasting levels of frost tolerance, the high frost tolerant (HFT) and the low frost tolerant (LFT) genotypes, were selected for comparative metabolomic research. The work focused on the analysis of leaf metabolite accumulation before and after seven separate time points of cold acclimation. Gas chromatography-mass spectrometry (GC/MS) was used to identify amino acids (alanine, proline, glycine, glutamic and aspartic acid, serine, lysine and asparagine), carbohydrates (fructose, glucose, sucrose, raffinose and trehalose) and their derivatives (mannitol, sorbitol and inositol) accumulated in leaves in low temperature. The observed differences in the level of frost tolerance between the analysed genotypes could be partially due to the time point of cold acclimation at which the accumulation level of crucial metabolite started to increase. In the HFT genotype, earlier accumulation was observed for proline and asparagine. The increased amounts of alanine, glutamic and aspartic acids, and asparagine during cold acclimation could be involved in the regulation of photosynthesis intensity in L. perenne. Among the analysed carbohydrates, only raffinose revealed a significant association with the acclimation process in this species.
Preference Mining Using Neighborhood Rough Set Model on Two Universes.
Zeng, Kai
2016-01-01
Preference mining plays an important role in e-commerce and video websites for enhancing user satisfaction and loyalty. Some classical methods are not available for the cold-start problem when the user or the item is new. In this paper, we propose a new model, called parametric neighborhood rough set on two universes (NRSTU), to describe the user and item data structures. Furthermore, the neighborhood lower approximation operator is used for defining the preference rules. Then, we provide the means for recommending items to users by using these rules. Finally, we give an experimental example to show the details of NRSTU-based preference mining for cold-start problem. The parameters of the model are also discussed. The experimental results show that the proposed method presents an effective solution for preference mining. In particular, NRSTU improves the recommendation accuracy by about 19% compared to the traditional method.
The New Big Science: What's New, What's Not, and What's the Difference
NASA Astrophysics Data System (ADS)
Westfall, Catherine
2016-03-01
This talk will start with a brief recap of the development of the ``Big Science'' epitomized by high energy physics, that is, the science that flourished after WWII based on accelerators, teams, and price tags that grew ever larger. I will then explain the transformation that started in the 1980s and culminated in the 1990s when the Cold War ended and the next big machine needed to advance high energy physics, the multi-billion dollar Superconducting Supercollider (SSC), was cancelled. I will go on to outline the curious series of events that ushered in the New Big Science, a form of research well suited to a post-Cold War environment that valued practical rather than esoteric projects. To show the impact of the New Big Science I will describe how decisions were ``set into concrete'' during the development of experimental equipment at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia.
Co-regulation analysis of co-expressed modules under cold and pathogen stress conditions in tomato.
Abedini, Davar; Rashidi Monfared, Sajad
2018-06-01
A primary mechanism for controlling the development of multicellular organisms is transcriptional regulation, which carried out by transcription factors (TFs) that recognize and bind to their binding sites on promoter region. The distance from translation start site, order, orientation, and spacing between cis elements are key factors in the concentration of active nuclear TFs and transcriptional regulation of target genes. In this study, overrepresented motifs in cold and pathogenesis responsive genes were scanned via Gibbs sampling method, this method is based on detection of overrepresented motifs by means of a stochastic optimization strategy that searches for all possible sets of short DNA segments. Then, identified motifs were checked by TRANSFAC, PLACE and Soft Berry databases in order to identify putative TFs which, interact to the motifs. Several cis/trans regulatory elements were found using these databases. Moreover, cross-talk between cold and pathogenesis responsive genes were confirmed. Statistical analysis was used to determine distribution of identified motifs on promoter region. In addition, co-regulation analysis results, illustrated genes in pathogenesis responsive module are divided into two main groups. Also, promoter region was crunched to six subareas in order to draw the pattern of distribution of motifs in promoter subareas. The result showed the majority of motifs are concentrated on 700 nucleotides upstream of the translational start site (ATG). In contrast, this result isn't true in another group. In other words, there was no difference between total and compartmentalized regions in cold responsive genes.
Dietary tyrosine benefits cognitive and psychomotor performance during body cooling.
O'Brien, Catherine; Mahoney, Caroline; Tharion, William J; Sils, Ingrid V; Castellani, John W
2007-02-28
Supplemental tyrosine is effective at limiting cold-induced decreases in working memory, presumably by augmenting brain catecholamine levels, since tyrosine is a precursor for catecholamine synthesis. The effectiveness of tyrosine for preventing cold-induced decreases in physical performance has not been examined. This study evaluated the effect of tyrosine supplementation on cognitive, psychomotor, and physical performance following a cold water immersion protocol that lowered body core temperature. Fifteen subjects completed a control trial (CON) in warm (35 degrees C) water and two cold water trials, each spaced a week apart. Subjects ingested an energy bar during each trial; on one cold trial (TYR) the bar contained tyrosine (300 mg/kg body weight), and on the other cold trial (PLB) and on CON the bar contained no tyrosine. Following each water immersion, subjects completed a battery of performance tasks in a cold air (10 degrees C) chamber. Core temperature was lower (p=0.0001) on PLB and TYR (both 35.5+/-0.6 degrees C) than CON (37.1+/-0.3 degrees C). On PLB, performance on a Match-to-Sample task decreased 18% (p=0.02) and marksmanship performance decreased 14% (p=0.002), compared to CON, but there was no difference between TYR and CON. Step test performance decreased by 11% (p=0.0001) on both cold trials, compared to CON. These data support previous findings that dietary tyrosine supplementation is effective for mitigating cold-induced cognitive performance such as working memory, even with reduced core temperature, and extends those findings to include the psychomotor task of marksmanship.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bates, G.J.; Germano, S.
Tests were undertaken with a Renault Express 1.4 litre converted to natural gas operation. The effect of cold starts at cold temperatures and vehicle weight on tail pipe emissions were investigated with petrol and natural gas operation over the FTP75 and the 91/441/EEC drive cycles. The results show that the emissions with natural gas are unaffected by cold temperature, unlike petrol emissions which are several times higher at -15{degree}-C than at 25{degree}-C. A crude simulation, accounting for the actual temperature, shows that the conversion of a significant quantity of light duty vehicles to natural gas operation could reduce the emissionsmore » of CO and HC by more than 90% in Switzerland. 15 refs., 17 figs., 8 tabs.« less
Economic assessment and optimal operation of CSP systems with TES in California electricity markets
NASA Astrophysics Data System (ADS)
Dowling, Alexander W.; Dyreson, Ana; Miller, Franklin; Zavala, Victor M.
2017-06-01
The economics and performance of concentrated power (CSP) systems with thermal energy storage (TES) inherently depend on operating policies and the surrounding weather conditions and electricity markets. We present an integrated economic assessment framework to quantify the maximum possible revenues from simultaneous energy and ancillary services sales by CSP systems. The framework includes both discrete start-up/shutdown restrictions and detailed physical models. Analysis of coinci-dental historical market and meteorological data reveals provision of ancillary services increases market revenue 18% to 37% relative to energy-only participation. Surprisingly, only 53% to 62% of these revenues are available through sole participation in the day-ahead market, indicating significant opportunities at faster timescales. Motivated by water-usage concerns and permitting requirements, we also describe a new nighttime radiative-enhanced dry-cooling system with cold-side storage that consumes no water and offers higher effciencies than traditional air-cooled designs. Operation of this new system is complicated by the cold-side storage and inherent coupling between the cooling system and power plant, further motivating integrated economic analysis.
Rašković, Brankica; Popović, Milica; Ostojić, Sanja; Anđelković, Boban; Tešević, Vele; Polović, Natalija
2015-01-01
Papain is a cysteine protease with wide substrate specificity and many applications. Despite its widespread applications, cold stability of papain has never been studied. Here, we used differential spectroscopy to monitor thermal denaturation process. Papain was the most stabile from 45 °C to 60 °C with ΔG°321 of 13.9±0.3 kJ/mol and Tm value of 84±1 °C. After cold storage, papain lost parts of its native secondary structures elements which gave an increase of 40% of intermolecular β-sheet content (band maximum detected at frequency of 1621 cm(-1) in Fourier transform infrared (FT-IR) spectrum) indicating the presence of secondary structures necessary for aggregation. The presence of protein aggregates after cold storage was also proven by analytical size exclusion chromatography. After six freeze-thaw cycles around 75% of starting enzyme activity of papain was lost due to cold denaturation and aggregation of unfolded protein. Autoproteolysis of papain did not cause significant loss of the protein activity. Upon the cold storage, papain underwent structural rearrangements and aggregation that correspond to other cold denatured proteins, rather than autoproteolysis which could have the commercial importance for the growing polypeptide based industry. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Qian, C.; Wang, J.; Dong, S.; Yin, H.; Burke, C.; Ciavarella, A.; Dong, B.; Freychet, N.; Lott, F. C.; Tett, S. F.
2017-12-01
It is controversial whether Asian mid-latitude cold surges are becoming more likely as a consequence of Arctic warming. Here, we present an event attribution study in mid-latitude Eastern China. A strong cold surge occurred during 21st-25th January 2016 affecting most areas of China, especially Eastern China. Daily minimum temperature (Tmin) records were broken at many stations. The area averaged anomaly of Tmin over the region (20-44N, 100-124E) for this pentad was the lowest temperature recorded since modern meteorological observations started in 1960. This cold event occurred in a background of the warmest winter Tmin since 1960. Given the vast damages caused by this extreme cold event in Eastern China and the previous mentioned controversy, it is compelling to investigate how much anthropogenic forcing agents have affected the probability of cold events with an intensity equal to or larger than the January 2016 extreme event. We use the Met Office Hadley Centre system for Attribution of extreme weather and Climate Events and station observations to investigate the effect of anthropogenic forcings on the likelihood of such a cold event. Anthropogenic influences are estimated to have reduced the likelihood of an extreme cold event in mid-winter with the intensity equal to or stronger than the record of 2016 in Eastern China by about 2/3.
NASA Astrophysics Data System (ADS)
Lu, Bohan; Lu, Xiaohui
2018-02-01
This study investigates the correlation between the residual stress and distortion behavior of a cold-rolled ring from the annealing to quenching-tempering (QT) process. Due to the cold-rolled process, the external periphery of the bearing ring experiences a compressive residual stress. To relieve the residual stress, cold-rolled rings are annealed at 700 °C which is higher than the starting temperature of recrystallization. When cold-rolled rings are annealed at 700 °C for 15 min, the compressive residual stress is reduced to zero and the outer diameter of the annealed ring becomes larger than that of a non-annealed sample, which is unrelated to annealing time. Simultaneously, the roundness and taper deviation do not obviously change compared with those of non-annealed sample. The stress relaxation during the annealing process was attributed to the recovery and recrystallization of ferrite. Annealing has a genetic influence on the following QT heat treatment, wherein the lowest residual stress is in the non-annealed cold-rolled ring. From the annealing to QT process, the deviation of the outer diameter, roundness, and taper increased with annealing time, a large extend than that of non-annealed samples.
Miljevic, B; Heringa, M F; Keller, A; Meyer, N K; Good, J; Lauber, A; Decarlo, P F; Fairfull-Smith, K E; Nussbaumer, T; Burtscher, H; Prevot, A S H; Baltensperger, U; Bottle, S E; Ristovski, Z D
2010-09-01
This study reports the potential toxicological impact of particles produced during biomass combustion by an automatic pellet boiler and a traditional logwood stove under various combustion conditions using a novel profluorescent nitroxide probe, BPEAnit. This probe is weakly fluorescent but yields strong fluorescence emission upon radical trapping or redox activity. Samples were collected by bubbling aerosol through an impinger containing BPEAnit solution, followed by fluorescence measurement. The fluorescence of BPEAnit was measured for particles produced during various combustion phases: at the beginning of burning (cold start), stable combustion after refilling with the fuel (warm start), and poor burning conditions. For particles produced by the logwood stove under cold-start conditions, significantly higher amounts of reactive species per unit of particulate mass were observed compared to emissions produced during a warm start. In addition, sampling of logwood burning emissions after passing through a thermodenuder at 250 degrees C resulted in an 80-100% reduction of the fluorescence signal of the BPEAnit probe, indicating that the majority of reactive species were semivolatile. Moreover, the amount of reactive species showed a strong correlation with the amount of particulate organic material. This indicates the importance of semivolatile organics in particle-related toxicity. Particle emissions from the pellet boiler, although of similar mass concentration, were not observed to lead to an increase in fluorescence signal during any of the combustion phases.
The Evolution of Gas Giant Entropy During Formation by Runaway Accretion
NASA Astrophysics Data System (ADS)
Berardo, David; Cumming, Andrew; Marleau, Gabriel-Dominique
2017-01-01
We calculate the evolution of gas giant planets during the runaway gas accretion phase of formation, to understand how the luminosity of young giant planets depends on the accretion conditions. We construct steady-state envelope models, and run time-dependent simulations of accreting planets with the code Modules for Experiments in Stellar Astrophysics. We show that the evolution of the internal entropy depends on the contrast between the internal adiabat and the entropy of the accreted material, parametrized by the shock temperature T 0 and pressure P 0. At low temperatures ({T}0≲ 300-1000 {{K}}, depending on model parameters), the accreted material has a lower entropy than the interior. The convection zone extends to the surface and can drive a high luminosity, leading to rapid cooling and cold starts. For higher temperatures, the accreted material has a higher entropy than the interior, giving a radiative zone that stalls cooling. For {T}0≳ 2000 {{K}}, the surface-interior entropy contrast cannot be accommodated by the radiative envelope, and the accreted matter accumulates with high entropy, forming a hot start. The final state of the planet depends on the shock temperature, accretion rate, and starting entropy at the onset of runaway accretion. Cold starts with L≲ 5× {10}-6 {L}⊙ require low accretion rates and starting entropy, and the temperature of the accreting material needs to be maintained close to the nebula temperature. If instead the temperature is near the value required to radiate the accretion luminosity, 4π {R}2σ {T}04˜ ({GM}\\dot{M}/R), as suggested by previous work on radiative shocks in the context of star formation, gas giant planets form in a hot start with L˜ {10}-4 {L}⊙ .
2015-09-01
injection system does not have any sensor feedback to alter injection timing to stabilize combustion. Fuel ignition quality was expected to impact...due to clouding of the camera window from residual soot in the piping, and was cleaned out prior to the next run. Figure 9. 46.9 Cetane Cold... sensor . 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 10 20 30 40 50 60 70 80 90 100 0 20 40 60 80 100 120 En gi ne R PM O pa ci ty , T em pe ra
NASA Astrophysics Data System (ADS)
Henao, Nilson; Kelouwani, Sousso; Agbossou, Kodjo; Dubé, Yves
2012-12-01
This paper investigates the Proton Exchange Membrane Fuel Cell (PEMFC) Cold Startup problem within the specific context of the Plugin Hybrid Electric Vehicles (PHEV). A global strategy which aims at providing an efficient method to minimize the energy consumption during the startup of a PEMFC is proposed. The overall control system is based on a supervisory architecture in which the Energy Management System (EMS) plays the role of the power flow supervisor. The EMS estimates in advance, the time to start the fuel cell (FC) based upon the battery energy usage during the trip. Given this estimation and the amount of additional energy required, the fuel cell temperature management strategy computes the most appropriate time to start heating the stack in order to reduce heat loss through the natural convection. As the cell temperature rises, the PEMFC is started and the reaction heat is used as a self-heating power source to further increase the stack temperature. A time optimal self-heating approach based on the Pontryagin minimum principle is proposed and tested. The experimental results have shown that the proposed approach is efficient and can be implemented in real-time on FC-PHEVs.
Cvetkovic, Jelena; Müller, Klaus; Baier, Margarete
2017-03-09
Priming improves an organism's performance upon a future stress. To test whether cold priming supports protection in spring and how it is affected by cold acclimation, we compared seven Arabidopsis accessions with different cold acclimation potentials in the field and in the greenhouse for growth, photosynthetic performance and reproductive fitness in March and May after a 14 day long cold-pretreatment at 4 °C. In the plants transferred to the field in May, the effect of the cold pretreatment on the seed yield correlated with the cold acclimation potential of the accessions. In the March transferred plants, the reproductive fitness was most supported by the cold pretreatment in the accessions with the weakest cold acclimation potential. The fitness effect was linked to long-term effects of the cold pretreatment on photosystem II activity stabilization and leaf blade expansion. The study demonstrated that cold priming stronger impacts on plant fitness than cold acclimation in spring in accessions with intermediate and low cold acclimation potential.
Automotive Stirling engine systems development
NASA Technical Reports Server (NTRS)
Richey, A. E.
1984-01-01
The objective of the Automotive Stirling Engine (ASE) program is to develop a Stirling engine for automotive use that provides a 30 percent improvement in fuel economy relative to a comparable internal-combustion engine while meeting emissions goals. This paper traces the engine systems' development efforts focusing on: (1) a summary of engine system performance for all Mod I engines; (2) the development, program conducted for the upgraded Mod I; and (3) vehicle systems work conducted to enhance vehicle fuel economy. Problems encountered during the upgraded Mod I test program are discussed. The importance of the EPA driving cycle cold-start penalty and the measures taken to minimize that penalty with the Mod II are also addressed.
Volvo Penta 4.3 GL E15 Emissions and Durability Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zoubul, G.; Cahoon, M.; Kolb, R.
2011-10-01
A new Volvo Penta carbureted 4.3 GL engine underwent emissions and dynamometer durability testing from break-in to expected end of life using an accelerated ICOMIA marine emissions cycle and E15 fuel. Only ethanol content was controlled. All aging used splash-blended E15 fuel. Exhaust emissions, exhaust gas temperature, torque, power, barometric pressure, air temperature, and fuel flow were measured at five intervals using site-blended E15 aging fuel and certification fuel (E0). The durability test cycle showed no noticeable impact on mechanical durability or engine power. Emissions performance degraded beyond the certification limit for this engine family, mostly occurring by 28% ofmore » expected life. Such degradation is inconsistent with prior experience. Comparisons showed that E15 resulted in lower CO and HC, but increased NOX, as expected for non-feedback-controlled carbureted engines with increased oxygen in the fuel. Fuel consumption also increased with E15 compared with E0. Throughout testing, poor starting characteristics were exhibited on E15 fuel for hot re-start and cold-start. Cranking time to start and smooth idle was roughly doubled compared with typical E0 operation. The carburetor was factory-set for lean operation to ensure emissions compliance. Test protocols did not include carburetor adjustment to account for increased oxygen in the E15 fuel.« less
Mental and cognitive performance in the cold.
Palinkas, L A
2001-08-01
Vigilance, attention, memory, and motivation are essential to adapting to the physiological changes that occur with prolonged exposure to the cold and to avoiding both the environmental hazards associated with cold and the health-related consequences of these hazards. This paper summarizes the effects of cold temperatures on cognitive performance and mood. Although the effects of hypothermic-induced cold temperatures on cognitive performance and mood have been well documented, evidence of nonhypothermic effects has been inconsistent. There is evidence of a dose-response relation involving decrements in cognitive performance with respect to decline in core body temperature and complexity of tasks performed. However, it is unclear whether these effects are due to distraction or increased arousal. Likewise, further research is required to test the efficacy of existing and proposed pharmacologic and nutritional countermeasures.
Demonstration of diesel fired coolant heaters in school bus applications : final report.
DOT National Transportation Integrated Search
2010-04-01
Engine block pre-heating can reduce fuel consumption, decrease pollution, extend engine life, and it is often necessary for reliably starting diesel engines in cold climates. This report describes the application and experience of applying 36 diesel ...
Nighttime kidney transplantation is associated with less pure technical graft failure.
Brunschot, Denise M D Özdemir-van; Hoitsma, Andries J; van der Jagt, Michel F P; d'Ancona, Frank C; Donders, Rogier A R T; van Laarhoven, Cees J H M; Hilbrands, Luuk B; Warlé, Michiel C
2016-07-01
To minimize cold ischemia time, transplantations with kidneys from deceased donors are frequently performed during the night. However, sleep deprivation of those who perform the transplantation may have adverse effects on cognitive and psychomotor performance and may cause reduced cognitive flexibility. We hypothesize that renal transplantations performed during the night are associated with an increased incidence of pure technical graft failure. A retrospective analysis of data of the Dutch Organ Transplant Registry concerning all transplants from deceased donors between 2000 and 2013 was performed. Nighttime surgery was defined as the start of the procedure between 8 p.m. and 8 a.m. The primary outcome measure was technical graft failure, defined as graft loss within 10 days after surgery without signs of (hyper)acute rejection. Of 4.519 renal transplantations in adult recipients, 1.480 were performed during the night. The incidence of pure technical graft failure was 1.0 % for procedures started during the night versus 2.6 % for daytime surgery (p = .001). In a multivariable model, correcting for relevant donor, recipient and graft factors, daytime surgery was an independent predictor of pure technical graft failure (p < .001). Limitation of this study is mainly to its retrospective design, and the influence of some relevant variables, such as the experience level of the surgeon, could not be assessed. We conclude that nighttime surgery is associated with less pure technical graft failures. Further research is required to explore factors that may positively influence the performance of the surgical team during the night.
NASA Astrophysics Data System (ADS)
Raatikka, Veli-Pekka; Rytkönen, Mika; Näyhä, Simo; Hassi, Juhani
2007-05-01
The prevalence of cold-related complaints and symptoms in the general population has remained unknown. As part of the nationwide FINRISK 2002 health survey performed in Finland, 8,723 people aged 25 64 years filled in a questionnaire asking about the number of hours spent weekly in cold air, their sensations during cold exposure, cold-related complaints, symptoms of diseases, and degradation of performance. Cold thermal sensations at +5°C to -5°C were reported by 35% of men and 46% of women. Almost all subjects reported at least some cold-related complaints, most commonly musculoskeletal pain (men 30%, women 27%), followed by respiratory (25% / 29%), white finger (15% / 18%) and episodic peripheral circulation symptoms (12% / 15%). Decreased mental or physical performance in cold was reported by 75% of men and 70% of women, most commonly impairing manual dexterity and tactile sense. With declining temperature, the first symptom to emerge was pain in the elbow or the forearm (at -3°C), followed by increased excretion of mucus from the lungs (-5°C), while most other symptoms appeared only at lower temperatures of -15°C to -20°C. Most symptoms showed little or no association with the weekly duration of exposure, with the exception of cold-induced pain at most sites. Although, in general, Finns are well adapted to the cold climate, the high prevalence of cold-related complaints poses a challenge to the health care system in terms of decreased performance and the possibility that such symptoms predict more serious health effects, such as increased mortality.
Consumer attitudes on cough and cold: US (ACHOO) survey results.
Blaiss, M S; Dicpinigaitis, P V; Eccles, R; Wingertzahn, M A
2015-08-01
The Attitudes of Consumers Toward Health, Cough, and Cold (ACHOO) survey was developed to better inform health care providers on the natural history and impact of common cold and cough, and related consumer experience and behaviors. Randomly selected US Internet/mobile device users were invited to participate in an online survey (N = 3333) in October 2012. Response quotas modeled upon 2010 US Census data ensured a demographically representative sample. To reduce potential bias from the quota design, 75% of the completed surveys were randomly selected as the primary analysis pool. Survey questions assessed participant demographics, frequency and duration of cough/cold symptoms, impact of symptoms on daily life, treatment preferences, and knowledge about cough/cold pathophysiology. In the past year, 84.6% of respondents had experienced at least one cold. Colds typically started with sore/scratchy throat (39.2%), nasal congestion (9.8%), and runny nose (9.3%) and lasted 3-7 days. Cough, the most common cold symptom (73.1%), had a delayed onset (typically 1-5 days after cold onset) and a long duration (>6 days in 35.2%). Nasal congestion and cough were the most bothersome symptoms. Many respondents waited until symptoms were 'bad enough' (42.6%) or multiple symptoms were present (20.2%) before using nonprescription medications. Drivers of choice included effectiveness in relieving symptoms, safety, and past experience. Respondents rarely consulted clinicians regarding treatment, and more than three-quarters had never received instructions from a clinician on how to choose a nonprescription cough/cold medication. Misperceptions regarding etiology and treatment of the common cold were prevalent. The main limitation is potential recall bias, since respondents had to recall cough/cold episodes over the prior year. The ACHOO survey confirms that cold is a common, bothersome experience and that there are gaps in consumers' knowledge of pathophysiology and appropriate management of cough/cold.
Not Just About the Science: Cold War Politics and the International Indian Ocean Expedition
NASA Astrophysics Data System (ADS)
Harper, K.
2016-12-01
The International Indian Ocean Expedition broke ground for a series of multi-national oceanographic expeditions starting in the late 1950s. In and of itself, it would have been historically significant—like the International Geophysical Year (1957-58)—for pulling together the international scientific community during the Cold War. However, US support for this and follow-on Indian Ocean expeditions were not just about the science; they were also about diplomacy, specifically efforts to bring non-aligned India into the US political orbit and out of the clutches of its Cold War enemy, the Soviet Union. This paper examines the behind-the-scenes efforts at the highest reaches of the US government to extract international political gain out of a large-scale scientific effort.
Characteristics of Subfreezing Operation of Polymer Electrolyte Membrane Fuel Cells
NASA Astrophysics Data System (ADS)
Mishler, Jeffrey Harris
Polymer Electrolyte Membrane (PEM) Fuel Cells are capable of high efficiency operation, and are free of NOx, SOx, and CO2 emissions when using hydrogen fuel, and ideally suited for use in transportation applications due to their high power density and low operating temperatures. However, under subfreezing conditions which may be encountered during winter seasons in some areas, product water will freeze within the membrane, cathode side catalyst layer and gas diffusion media, leading to voltage loss and operation failure. Experiments were undertaken in order to characterize the amount and location of water during fuel cell operation. First, in-situ neutron radiography was undertaken on the fuel cells at a normal operating temperature for various operating current densities, inlet relative humidities, and diffusion media hydrophobicities. It was found that more hydrophobic cathode microporous layer (MPL) or hydrophilic anode MPL may result in a larger amount of water transporting back to the anode. The water profiles along the channels were measured and the point of liquid water emergence, where two phase flow begins, was compared to previous models. Secondly, under subfreezing temperatures, neutron imaging showed that water ice product accumulates because of lack of a water removal mechanism. Water was observed under both the lands and channels, and increased almost linearly with time. It is found that most ice exists in the cathode side. With evidence from experimental observation, a cold start model was developed and explained, following existing approaches in the literature. Three stages of cold start are explained: membrane saturation, ice storage in catalyst layer pores, and then ice melting. The voltage losses due to temperature change, increased transport resistance, and reduced electrochemical surface area. The ionic conductivity of the membrane at subfreezing temperatures was modeled. Voltage evolution over time for isothermal cold starts was predicted and validated against experimental data. The ice coverage coefficient was shown to be a key variable in matching with experimental data. From model analysis, it appears that the coulombs of charge passed before operation failure is an important parameter characterizing PEM fuel cell cold start. To investigate the coulombs of charge and its determining factors, PEM fuel cells were constructed to measure the effects of membrane configuration (thickness and initial state), catalyst layer configuration (thickness and ionomer-carbon ratio), current density, and temperature on the quantity. It was found that subfreezing temperature, ionomer-catalyst ratio, and catalyst-layer thickness significantly affect the amount of charge transferred before operational failure, whereas the membrane thickness and initial hydration level have limited effect for the considered cases. In addition, degradation of the catalyst layer was observed and quantified. These results improve the fundamental understanding of characteristics of subfreezing operation and thus are valuable for automobile applications of PEM fuel cells. The model directly relates the material properties to voltage loss, and predicts voltage evolution, thus providing a way for material optimization and diagnostics. Additionally, insights into component design and operating conditions can be used to better optimize the fuel cell for cold start-up of the vehicle.
New procedure speeds cold start, protects turbine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallard, R.E.; Jordan, C.A.
1995-09-01
System dispatch from today`s power plants must consider availability of purchase power (buy and sell), fuel prices, and unit availability and efficiency. To gain the best combination of these factors, steam units must be capable of quick removal and return to service. However, unit startups are expensive, time consuming nd operationally demanding. For example, excessive thermal stresses can be catastrophic to a unit. With those factors in mind, Jacksonville Electric Authority (JEA) developed the ``valve open start`` procedure described here.
40 CFR 1065.925 - PEMS preparation for field testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 1065.925 Section 1065.925 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... purge any gaseous sampling PEMS instruments with ambient air until sampling begins to prevent system contamination from excessive cold-start emissions. (e) Conduct calibrations and verifications. (f) Operate any...
... foods and drink lots of water to prevent dehydration. If you have a sore throat, gargle saltwater, drink tea with honey, or suck on hard candy or ice pops. You can get some nutrition and soothe your throat with cold fruit smoothies or low-fat shakes. When you start ...
Common cold - how to treat at home
... you have: Difficulty breathing Sudden chest pain or abdominal pain Sudden dizziness Acting strangely Severe vomiting that does not go away Also call your provider if: You start acting strangely Your symptoms get worse or do not improve after 7 to 10 days
Atomtronics: Material and Device Physics of Quantum Gases
matter physics to electrical engineering. Our projects title Atomtronics: Material and device physics of quantum gases illustrates the chasm we bridged...starting from therich and fundamental physics already revealed with cold atoms systems, then leading to an understanding of the functional materials
Induced vasodilation as treatment for Raynaud's disease.
Jobe, J B; Sampson, J B; Roberts, D E; Beetham, W P
1982-11-01
We examined the efficacy of induced vasodilation as a treatment of idiopathic Raynaud's disease. Eight persons with Raynaud's disease and seven normal persons each received 27 simultaneous pairings of hand immersion in warm water (43 degrees C) for 10 minutes with exposure of the whole body to cold (0 degrees C). A second group of seven normal persons and nine persons with Raynaud's disease received no treatments. All subjects had cold test exposures (0 degrees C) at the start and end of the study. Subjects with Raynaud's disease who received treatments showed significant increases in digital temperatures (2.2 degrees C) during the cold test compared with the values of untreated subjects with Raynaud's disease (p less than 0.05); normal subjects who had received treatments showed no difference from those who had not. Digital temperatures of subjects with Raynaud's disease after treatment increased to levels approaching those of normal subjects, although they showed lower digital temperatures during initial exposure to cold (p less than 0.01). This therapy offers a practical alternative to traditional treatments.
Dowell, S F; Schwartz, B; Phillips, W R
1998-10-15
This article summarizes the principles of judicious antimicrobial therapy for three of the five conditions--cough, pharyngitis, the common cold--that account for most of the outpatient use of these drugs in the United States. The principles governing the other two conditions, otitis media and acute sinusitis, were presented in the previous issue. This article summarizes evidence against the use of antibiotic treatment for illness with cough or bronchitis in children, unless the cough is prolonged. Although empiric treatment may be started in patients with pharyngitis when streptococcal infection is suspected, the authors recommend withholding antibiotic treatment until antigen testing or culture is positive. There is never any indication for antibiotic treatment of the common cold; it is important to understand the natural history of colds, because symptoms such as mucopurulent rhinitis or cough, even when they persist for up to two weeks, do not necessarily indicate bacterial infection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jana, Saumyadeep; Overman, Nicole; Varga, Tamas
The effect of sub-eutectoid heat treatment on the phase transformation behavior in rolled U-10 wt.percent Mo (U10Mo) foils was systematically investigated. The as-cast 5 mm thick foils were initially homogenized at 900 degrees C for 48 hours and were hot rolled to 2 mm and later cold rolled down to 0.2 mm. Three starting microstructures were evaluated: (i) hot- + cold-rolled to 0.2 mm (as-rolled condition), (ii) hot- + cold-rolled to 0.2 mm + annealed at 700 deg. C for 1 hour, and (iii) hot- + cold-rolled to 0.2 mm + annealed at 1000 deg. C for 60 hours. U10Momore » rolled foils went through various degrees of decomposition when subjected to the sub-eutectoid heat-treatment step and formed a lamellar microstructure through a cellular reaction mostly along the previous γ-UMo grain boundaries.« less
The Effects of Cold Whirlpool on Power, Speed, Agility, and Range of Motion
Patterson, Stephen M.; Udermann, Brian E.; Doberstein, Scott T.; Reineke, David M.
2008-01-01
The purpose was to determine if cold whirlpool treatment decreases functional performance equally regardless of gender. A secondary aim was to determine if there is a gradual increase in functional performance across time. Twenty-one college-aged subjects volunteered to participate in this study and were required to perform four measures of functional performance including: counter movement vertical jump, T-test, 36.58-meter dash (40-yard), and active range of motion of the ankle. Participants were treated with a 20 minute, 10 degree Celsius cold whirlpool following the pre-test of a given functional performance measure. Participants demonstrated significant decreases in counter movement vertical jump, T-test, and 40-yard dash performance immediately following treatment. Vertical jump performance remained impaired for at least 32 minutes. While both the T-test and 40-yard dash were affected for 7 and 22 minutes post- treatment, respectively. Participants also demonstrated significant decreases in peak power and average power immediately after and for 32 minutes post-treatment. Dorsiflexion was significantly decreased 7 and 12 minutes following treatment. There were no differences for plantar flexion, inversion, or eversion. These data suggest functional performance was affected immediately following and for up to 32 minutes after cold whirlpool treatment. It was also evident that there is a gradual performance increase for each measure of functional performance across time. Therefore, the consequences should be carefully considered before returning athletes to activity following cold whirlpool treatment. Key pointsCryotherapy is a common and highly effective modality in treating acute and chronic athletic injuries.The results indicated that cold whirlpool does have an immediate and subsequent effect on functional performance.Understanding how cold whirlpool adversely affects functional performance allows clinicians to continue using this modality before vigorous athletic activity. PMID:24149907
Actively controlling coolant-cooled cold plate configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
Cooling apparatuses are provided to facilitate active control of thermal and fluid dynamic performance of a coolant-cooled cold plate. The cooling apparatus includes the cold plate and a controller. The cold plate couples to one or more electronic components to be cooled, and includes an adjustable physical configuration. The controller dynamically varies the adjustable physical configuration of the cold plate based on a monitored variable associated with the cold plate or the electronic component(s) being cooled by the cold plate. By dynamically varying the physical configuration, the thermal and fluid dynamic performance of the cold plate are adjusted to, formore » example, optimally cool the electronic component(s), and at the same time, reduce cooling power consumption used in cooling the electronic component(s). The physical configuration can be adjusted by providing one or more adjustable plates within the cold plate, the positioning of which may be adjusted based on the monitored variable.« less
Baldauf, Rich W; Gabele, Pete; Crews, William; Snow, Richard; Cook, J Rich
2005-09-01
The U.S. Environmental Protection Agency (EPA) implemented a program to identify tailpipe emissions of criteria and air-toxic contaminants from in-use, light-duty low-emission vehicles (LEVs). EPA recruited 25 LEVs in 2002 and measured emissions on a chassis dynamometer using the cold-start urban dynamometer driving schedule of the Federal Test Procedure. The emissions measured included regulated pollutants, particulate matter, speciated hydrocarbon compounds, and carbonyl compounds. The results provided a comparison of emissions from real-world LEVs with emission standards for criteria and air-toxic compounds. Emission measurements indicated that a portion of the in-use fleet tested exceeded standards for the criteria gases. Real-time regulated and speciated hydrocarbon measurements demonstrated that the majority of emissions occurred during the initial phases of the cold-start portion of the urban dynamometer driving schedule. Overall, the study provided updated emission factor data for real-world, in-use operation of LEVs for improved emissions modeling and mobile source inventory development.
Methanol injection and recovery in a large turboexpander plant. [Canada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, K.; Wolfe, L.
1981-01-01
Methanol is used to prevent hydrate formation in Petro-Canada's 2000 MMSCFD Empress expander plant. Injection and recovery facilities have operated essentially trouble-free since start-up late in 1979. A portion of the methanol recovery section has been modified to provide removal of the H/sub 2/S and most of the COS from the propane product stream, concurrent with methanol recovery. The Empress straddle plant strips natural gas liquids from pipeline gas leaving Alberta for eastern Canadian and U.S. markets. The original cold oil absorption plant, started up in 1964 and expanded in 1967, recovered over 90% of the propane and virtually allmore » of the heavier components. In 1976, a market for ethane was secured as feedstock for the world-scale ethylene complex under construction in Alberta, and it was decided to replace the cold oil plant with a turboexpander facility. The plant and its operations are described in some detail. 2 refs.« less
Enhancement of a UASB-septic tank performance for decentralised treatment of strong domestic sewage.
Mahmoud, Nidal; van Lier, Jules B
2011-01-01
The possibility of enhancing the process performance of the UASB-septic tank for treating strong sewage in Palestine by means of inoculating the reactor with well adapted anaerobic sludge and/or adding a packing media to the upper part of the reactor, creating an anaerobic hybrid (AH)-septic tank, was investigated. To achieve these objectives, two community onsite UASB-septic tank and AH-septic tank were operated in parallel at 2 days HRT for around 8 months overlapping the cold and hot periods of the year in Palestine. The achieved removal efficiencies of CODtot in the UASB-septic tank and AH-septic tank during the first months of operation, coinciding with the cold period and the subsequent hot period, were respectively 50 (+/- 15)% and 48 (+/- 15)% and 66 (+/- 8)% and 55 (+/- 8)%. This shows that the UASB-septic tank performed significantly better (p < 0.05) than the AH-septic tank after rather long periods of operation. The difference in the CODtot removal efficiency was mainly due to the better CODss removal efficiencies in the UASB-septic tank. The removal efficiencies over the last 50 days of operation for CODtot, CODsus, CODcol and CODdis were 70, 72, 77 and 55% and 53, 54, 78 and 45% for the UASB-septic tank and AH-septic tank, respectively. Comparing the here achieved COD removal efficiencies with previously reported efficiencies of UASB-septic tanks operated in Palestine shows that the reactor performance in terms of COD removal and conversion, during the first 8 months of operation, has improved substantially by being started with well adapted anaerobic sludge, simulating and predicting long-term performance. Adding packing media did not lead to an improvement.
Experiments on high speed ejectors
NASA Technical Reports Server (NTRS)
Wu, J. J.
1986-01-01
Experimental studies were conducted to investigate the flow and the performance of thrust augmenting ejectors for flight Mach numbers in the range of 0.5 to 0.8, primary air stagnation pressures up to 107 psig (738 kPa), and primary air stagnation temperatures up to 1250 F (677 C). The experiment verified the existence of the second solution ejector flow, where the flow after complete mixing is supersonic. Thrust augmentation in excess of 1.2 was demonstrated for both hot and cold primary jets. The experimental ejector performed better than the corresponding theoretical optimal first solution ejector, where the mixed flow is subsonic. Further studies are required to realize the full potential of the second solution ejector. The research program was started by the Flight Dynamics Research Corporation (FDRC) to investigate the characteristic of a high speed ejector which augments thrust of a jet at high flight speeds.
Information filtering via biased random walk on coupled social network.
Nie, Da-Cheng; Zhang, Zi-Ke; Dong, Qiang; Sun, Chongjing; Fu, Yan
2014-01-01
The recommender systems have advanced a great deal in the past two decades. However, most researchers focus their attentions on mining the similarities among users or objects in recommender systems and overlook the social influence which plays an important role in users' purchase process. In this paper, we design a biased random walk algorithm on coupled social networks which gives recommendation results based on both social interests and users' preference. Numerical analyses on two real data sets, Epinions and Friendfeed, demonstrate the improvement of recommendation performance by taking social interests into account, and experimental results show that our algorithm can alleviate the user cold-start problem more effectively compared with the mass diffusion and user-based collaborative filtering methods.
Information Filtering via Biased Random Walk on Coupled Social Network
Dong, Qiang; Fu, Yan
2014-01-01
The recommender systems have advanced a great deal in the past two decades. However, most researchers focus their attentions on mining the similarities among users or objects in recommender systems and overlook the social influence which plays an important role in users' purchase process. In this paper, we design a biased random walk algorithm on coupled social networks which gives recommendation results based on both social interests and users' preference. Numerical analyses on two real data sets, Epinions and Friendfeed, demonstrate the improvement of recommendation performance by taking social interests into account, and experimental results show that our algorithm can alleviate the user cold-start problem more effectively compared with the mass diffusion and user-based collaborative filtering methods. PMID:25147867
Durability and robustness of tubular molten carbonate fuel cells
NASA Astrophysics Data System (ADS)
Kawase, Makoto
2017-12-01
One anticipated system for high-efficiency power generation is the combination of syngas from gasification and high temperature fuel cells. The system uses a pressurization system, and it takes into account poisoning by impurities in the syngas. The durability and robustness of the fuel cells used in this system are an important issue for commercial applications. This study focuses on tubular molten carbonate fuel cells (MCFCs), which seem to be relatively durable compared with conventional planar-type MCFCs. Various power generation tests were performed in order to evaluate the durability and robustness of the tubular MCFCs. After continuous generation tests at 0.3 MPa, the cell voltage decay rate was found to be 0.8 mV/1000 h at 0.2 A/cm2. Moreover, it was found to be possible to generate power stably with fuel gas containing 20 ppm H2S. When the differential pressure between the anode and cathode was set to 0.1 MPa, the power generation tests were performed without gas leakage. In addition, starting (heating) and stopping (cooling) could be done in a short period, meaning that the cold start/stop characteristics are favorable. Therefore, the tubular MCFC was confirmed to have the durability necessary for a power generation system.
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Valco, Mark J.
1999-01-01
The NASA Lewis Research Center is capitalizing on breakthroughs in foil air bearing performance, tribological coatings, and computer analyses to formulate the Oil-free Turbomachinery Program. The program s long-term goal is to develop an innovative, yet practical, oil-free aeropropulsion gas turbine engine that floats on advanced air bearings. This type of engine would operate at higher speeds and temperatures with lower weight and friction than conventional oil-lubricated engines. During startup and shutdown, solid lubricant coatings are required to prevent wear in such engines before the self-generating air-lubrication film develops. NASA s Tribology Branch has created PS304, a chrome-oxide-based plasma spray coating specifically tailored for shafts run against foil bearings. PS304 contains silver and barium fluoride/calcium fluoride eutectic (BaF2/CaF2) lubricant additives that, together, provide lubrication from cold start temperatures to over 650 C, the maximum use temperature for foil bearings. Recent lab tests show that bearings lubricated with PS304 survive over 100 000 start-stop cycles without experiencing any degradation in performance due to wear. The accompanying photograph shows a test bearing after it was run at 650 C. The rubbing process created a "polished" surface that enhances bearing load capacity.
An item-oriented recommendation algorithm on cold-start problem
NASA Astrophysics Data System (ADS)
Qiu, Tian; Chen, Guang; Zhang, Zi-Ke; Zhou, Tao
2011-09-01
Based on a hybrid algorithm incorporating the heat conduction and probability spreading processes (Proc. Natl. Acad. Sci. U.S.A., 107 (2010) 4511), in this letter, we propose an improved method by introducing an item-oriented function, focusing on solving the dilemma of the recommendation accuracy between the cold and popular items. Differently from previous works, the present algorithm does not require any additional information (e.g., tags). Further experimental results obtained in three real datasets, RYM, Netflix and MovieLens, show that, compared with the original hybrid method, the proposed algorithm significantly enhances the recommendation accuracy of the cold items, while it keeps the recommendation accuracy of the overall and the popular items. This work might shed some light on both understanding and designing effective methods for long-tailed online applications of recommender systems.
40 CFR 1066.410 - Dynamometer test procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... drive mode. (For purposes of this paragraph (g), the term four-wheel drive includes other multiple drive... Dynamometer test procedure. (a) Dynamometer testing may consist of multiple drive cycles with both cold-start...-setting part identifies the driving schedules and the associated sample intervals, soak periods, engine...
Comparison of real-world and certification emission rates for light duty gasoline vehicles.
Khan, Tanzila; Frey, H Christopher
2018-05-01
U.S. light duty vehicles are subject to the U.S. Environmental Protection Agency (EPA) emission standards. Emission compliance is determined by certification testing of selected emissions from representative vehicles on standard driving cycles using chassis dynamometers. Test results are also used in many emission inventories. The dynamometer based emission rates are adjusted to provide the certification levels (CL), which must be lower than the standards for compliance. Although standard driving cycles are based on specific observations of real-world driving, they are not necessarily real-world representative. A systematic comparison of the real-world emission rates of U.S. light duty gasoline vehicles (LDGVs) versus CL, and emission standards has not been previously reported. The purpose of this work is to compare regulatory limits (both CLs and emission standards) and the real-world emissions of LDGVs. The sensitivity of the comparisons to cold start emission was assessed. Portable Emission Measurement Systems (PEMS) were used to measure hot stabilized exhaust emissions of 122 LDGVs on a specified 110 mile test route. Cold start emissions were measured with PEMS for a selected vehicle sample of 32 vehicles. Emissions were measured for carbon dioxide (CO 2 ), carbon monoxide (CO), hydrocarbons (HC) and nitrogen oxides (NO x ). For each vehicle, a Vehicle Specific Power (VSP) modal emission rate model was developed. The VSP modal rates were weighted by the standard driving cycles and real-world driving cycles to estimate the respective cycle average emission rates (CAERs). Measured vehicles were matched with certification test vehicles for comparison. For systematic trends in comparison, vehicles were classified into four groups based on the Tier 1 and Tier 2 emission regulation, and the vehicle type such as passenger car and passenger truck. Depending on the cycle-pollutant and the vehicle groups, hot stabilized CAERs are on average either statistically significantly higher than or significantly not different from the CLs, with the exception of CO on the US06 cycle, for which real-world rates are lower than CLs. Compared to the emission standards, hot stabilized CAERs are on average significantly lower. However, comparisons of CAERs and standards are sensitive to cold start emissions. For some combinations of pollutants and vehicle groups, cold start inclusive CAERs are higher than the corresponding CLs and as high as the standards. The CLs, which are based on standard driving cycles, tend to underestimate real-world emission rates. Therefore, emission inventory estimates using certification test results are potentially underestimated. Copyright © 2017 Elsevier B.V. All rights reserved.
Review on cold-formed steel connections.
Lee, Yeong Huei; Tan, Cher Siang; Mohammad, Shahrin; Tahir, Mahmood Md; Shek, Poi Ngian
2014-01-01
The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed.
Review on Cold-Formed Steel Connections
Tan, Cher Siang; Mohammad, Shahrin; Md Tahir, Mahmood; Shek, Poi Ngian
2014-01-01
The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed. PMID:24688448
The near-infrared spectral energy distribution of β Pictoris b
NASA Astrophysics Data System (ADS)
Bonnefoy, M.; Boccaletti, A.; Lagrange, A.-M.; Allard, F.; Mordasini, C.; Beust, H.; Chauvin, G.; Girard, J. H. V.; Homeier, D.; Apai, D.; Lacour, S.; Rouan, D.
2013-07-01
Context. A gas giant planet has previously been directly seen orbiting at 8-10 AU within the debris disk of the ~12 Myr old star β Pictoris. The β Pictoris system offers the rare opportunity of both studying the physical and atmospheric properties of an exoplanet placed on a wide orbit and establishing its formation scenario. Aims: We aim to build the 1-5 μm spectral energy distribution of the planet for the first time. Our goal is to provide secure and accurate constraints on its physical and chemical properties. Methods: We obtained J (1.265 μm), H (1.66 μm), and M' (4.78 μm) band angular differential imaging of the system between 2011 and 2012. We used Markov chain Monte Carlo simulations of the astrometric data to revise constraints on the orbital parameters of the planet. Photometric measurements were compared to those of ultra-cool dwarfs and young companions. They were combined with existing photometry (2.18, 3.80, and 4.05 μm) and compared to predictions from 7 PHOENIX-based atmospheric models in order to derive the atmospheric parameters (Teff, log g) of β Pictoris b. Predicted properties from ("hot-start", "cold-start", and "warm start") evolutionary models were compared to independent constraints on the mass of β Pictoris b. We used planet-population synthesis models following the core-accretion paradigm to discuss the planet's possible origin. Results: We detect the planetary companion in our four-epoch observations. We estimate J = 14.0 ± 0.3, H = 13.5 ± 0.2, and M' = 11.0 ± 0.3 mag. Our new astrometry consolidates previous semi-major axis (8-10 AU) and excentricity (e ≤ 0.15) estimates of the planet. The location of β Pictoris b in color-magnitude diagrams suggests it has spectroscopic properties similar to L0-L4 dwarfs. This enables one to derive Log10 (L / L⊙) = - 3.87 ± 0.08 for the companion. The analysis with atmospheric models reveals that the planet has a dusty atmosphere with Teff = 1700 ± 100K and log g = 4.0 ± 0.5. "Hot-start" evolutionary models give a new mass of 10-2+3 MJup from Teff and 9-2+3 MJup from luminosity. Predictions of "cold-start" models are still inconsistent with independent constraints on the planet mass. "Warm-start" models constrain the mass to M ≥ 6 MJup and the initial entropies to values (Sinit ≥ 9.3Kb / baryon) midway between those considered for cold/hot-start models, but probably closer to those of hot-start models. Based on observations made with ESO telescopes at the Paranal Observatory under programs 073.D-0534, 076.C-0339, 078.C-0472, 084.C-0739, 085.D-0625, 088.C-0358, and 090.C-0653.Appendices A and B are available in electronic form at http://www.aanda.org
10 CFR 430.3 - Materials incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... Standard for Fluorescent Lamps-Instant-start and Cold-Cathode Types-Dimensional and Electrical...-1995 (“ANSI C78.20”), American National Standard for electric lamps—A, G, PS, and Similar Shapes with...
Exhaust Emission Rates for Heavy-Duty On road Vehicles in MOVES201X
Updated running exhaust gaseous emission rates (THC, CO, NOx, CO2) for heavy-duty diesel trucks model year 2010 and later based on portable emission measurements from the manufacturer-run, heavy-duty in-use testing (HDIUT) program. Updated cold start emission rates and soak adjus...
Stirling Engine External Heat System Design with Heat Pipe Heater.
1986-07-01
Figure 10. However, the evaporator analysis is greatly simplified by making the conservative assumption of constant heat flux. This assumption results in...number Cold Start Data * " ROM density of the metal, gr/cm 3 CAPM specific heat of the metal, cal./gr. K ETHG effective gauze thickness: the
DIESEL ENGINE EFFICIENCY AND EMISSIONS IMPROVEMENT VIA PISTON TEMPERATURE CONTROL - PHASE I
... do get it after they've gotten the shot often get less severe cases, which means they get better quicker. What Happens When You Have Chickenpox? Chickenpox may start out seeming like a cold: You might have a runny or stuffy nose, sneezing, and a cough. But 1 to 2 days later, the rash begins, often ...
Review: Fuel Volatility Standards and Spark-Ignition Vehicle Driveability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yanowitz, Janet; McCormick, Robert L.
2016-03-14
We've put spark-ignition engine fuel standards in place in order to ensure acceptable hot and cold weather driveability (HWD and CWD). Vehicle manufacturers and fuel suppliers have developed systems that meet our driveability requirements so effectively that drivers overwhelmingly find that their vehicles reliably start up and operate smoothly and consistently throughout the year. For HWD, fuels that are too volatile perform more poorly than those that are less volatile. Vapor lock is the apparent cause of poor HWD, but there is conflicting evidence in the literature as to where in the fuel system it occurs. Most studies have foundmore » a correlation between degraded driveability and higher dry vapor pressure equivalent or lower TV/L = 20, and less consistently with a minimum T50. For CWD, fuels with inadequate volatility can cause difficulty in starting and rough operation during engine warmup. The Driveability Index (DI)-a function of T10, T50, and T90-is well correlated with CWD in hydrocarbon fuels. For ethanol-containing fuels, a correction factor to the DI equation improves the correlation with CWD, although the best value for that factor has still not been determined. Ethanol increases the heat of vaporization. But, this is likely insignificant for E15 and lower concentration fuels. The impact of ethanol on driveability is likely due to its direct effect on vapor pressure at cold temperatures. For E51-E83 or flex-fuel blends, ASTM sets a minimum vapor pressure; however, published data suggest that a correction for the amount of ethanol in the fuel is needed to accurately predict CWD, possibly because ethanol has a higher lower-flammability limit.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, C; Chetty, I; Mao, W
Purpose: To utilize deformable dose accumulation (DDA) to determine how cold spots within the PTV change over the course of fractionated head and neck (H&N) radiotherapy. Methods: Voxel-based dose was tracked using a DDA platform. The DDA process consisted of B-spline-based deformable image registration (DIR) and dose accumulation between planning CT’s and daily cone-beam CT’s for 10 H&N cancer patients. Cold spots within the PTV (regions receiving less than the prescription, 70 Gy) were contoured on the cumulative dose distribution. These cold spots were mapped to each fraction, starting from the first fraction to determine how they changed. Spatial correlationmore » between cold spot regions over each fraction, relative to the last fraction, was computed using the Jaccard index Jk (Mk,N), where N is the cold spot within the PTV at the end of the treatment, and Mk the same region for fraction k. Results: Figure 1 shows good spatial correlation between cold spots, and highlights expansion of the cold spot region over the course of treatment, as a result of setup uncertainties, and anatomical changes. Figure 2 shows a plot of Jk versus fraction number k averaged over 10 patients. This confirms the good spatial correlation between cold spots over the course of treatment. On average, Jk reaches ∼90% at fraction 22, suggesting that possible intervention (e.g. reoptimization) may mitigate the cold spot region. The cold spot, D99, averaged over 10 patients corresponded to a dose of ∼65 Gy, relative to the prescription dose of 70 Gy. Conclusion: DDA-based tracking provides spatial dose information, which can be used to monitor dose in different regions of the treatment plan, thereby enabling appropriate mid-treatment interventions. This work is supported in part by Varian Medical Systems, Palo Alto, CA.« less
NASA Astrophysics Data System (ADS)
Tomsic, Z.; Rajsl, I.; Filipovic, M.
2017-11-01
Wind power varies over time, mainly under the influence of meteorological fluctuations. The variations occur on all time scales. Understanding these variations and their predictability is of key importance for the integration and optimal utilization of wind in the power system. There are two major attributes of variable generation that notably impact the participation on power exchanges: Variability (the output of variable generation changes and resulting in fluctuations in the plant output on all time scales) and Uncertainty (the magnitude and timing of variable generation output is less predictable, wind power output has low levels of predictability). Because of these variability and uncertainty wind plants cannot participate to electricity market, especially to power exchanges. For this purpose, the paper presents techno-economic analysis of work of wind plants together with combined cycle gas turbine (CCGT) plant as support for offering continues power to electricity market. A model of wind farms and CCGT plant was developed in program PLEXOS based on real hourly input data and all characteristics of CCGT with especial analysis of techno-economic characteristics of different types of starts and stops of the plant. The Model analyzes the followings: costs of different start-stop characteristics (hot, warm, cold start-ups and shutdowns) and part load performance of CCGT. Besides the costs, the technical restrictions were considered such as start-up time depending on outage duration, minimum operation time, and minimum load or peaking capability. For calculation purposes, the following parameters are necessary to know in order to be able to economically evaluate changes in the start-up process: ramp up and down rate, time of start time reduction, fuel mass flow during start, electricity production during start, variable cost of start-up process, cost and charges for life time consumption for each start and start type, remuneration during start up time regarding expected or unexpected starts, the cost and revenues for balancing energy (important when participating in electricity market), and the cost or revenues for CO2-certificates. Main motivation for this analysis is to investigate possibilities to participate on power exchanges by offering continues guarantied power from wind plants by backing-up them with CCGT power plant.
Nguyen, Phuong; Greene, Elizabeth; Ishola, Peter; Huff, Geraldine; Donoghue, Annie; Bottje, Walter; Dridi, Sami
2015-01-01
Low environmental temperatures are among the most challenging stressors in poultry industries. Although landmark studies using acute severe cold exposure have been conducted, still the molecular mechanisms underlying cold-stress responses in birds are not completely defined. In the present study we determine the effect of chronic mild cold conditioning (CMCC) on growth performances and on the expression of key metabolic-related genes in three metabolically important tissues: brain (main site for feed intake control), liver (main site for lipogenesis) and muscle (main site for thermogenesis). 80 one-day old male broiler chicks were divided into two weight-matched groups and maintained in two different temperature floor pen rooms (40 birds/room). The temperature of control room was 32°C, while the cold room temperature started at 26.7°C and gradually reduced every day (1°C/day) to reach 19.7°C at the seventh day of the experiment. At day 7, growth performances were recorded (from all birds) and blood samples and tissues were collected (n = 10). The rest of birds were maintained at the same standard environmental condition for two more weeks and growth performances were measured. Although feed intake remained unchanged, body weight gain was significantly increased in CMCC compared to the control chicks resulting in a significant low feed conversion ratio (FCR). Circulating cholesterol and creatine kinase levels were higher in CMCC chicks compared to the control group (P<0.05). CMCC significantly decreased the expression of both the hypothalamic orexigenic neuropeptide Y (NPY) and anorexigenic cocaine and amphetamine regulated transcript (CART) in chick brain which may explain the similar feed intake between the two groups. Compared to the control condition, CMCC increased the mRNA abundance of AMPKα1/α2 and decreased mTOR gene expression (P<0.05), the master energy and nutrient sensors, respectively. It also significantly decreased the expression of fatty acid synthase (FAS) gene in chick brain compared to the control. Although their roles are still unknown in avian species, adiponectin (Adpn) and its related receptors (AdipoR1 and 2) were down regulated in the brain of CMCC compared to control chicks (P<0.05). In the liver, CMCC significantly down regulated the expression of lipogenic genes namely FAS, acetyl-CoA carboxylase alpha (ACCα) and malic enzyme (ME) and their related transcription factors sterol regulatory element binding protein 1/2 (SREBP-1 and 2). Hepatic mTOR mRNA levels and phosphorylated mTOR at Ser2448 were down regulated (P<0.05), however phosphorylated ACCαSer79 (inactivation) was up regulated (P<0.05) in CMCC compared to control chicks, indicating that CMCC switch hepatic catabolism on and inhibits hepatic lipogenesis. In the muscle however, CMCC significantly up regulated the expression of carnitine palmitoyltransferase 1 (CPT-1) gene and the mRNA and phosphorylated protein levels of mTOR compared to the control chicks, indicating that CMCC enhanced muscle fatty acid β-oxidation. In conclusion, this is the first report indicating that CMCC may regulate AMPK-mTOR expression in a tissue specific manner and identifying AMPK-mTOR as a potential molecular signature that controls cellular fatty acid utilization (inhibition of hepatic lipogenesis and induction of muscle fatty acid β-oxidation) to enhance growth performance during mild cold acclimation.
Performance of hybrid subsurface constructed wetland system for piggery wastewater treatment.
Zhang, X; Inoue, T; Kato, K; Harada, J; Izumoto, H; Wu, D; Sakuragi, H; Ietsugu, H; Sugawara, Y
2016-01-01
The objective of this study was to evaluate performance of a hybrid constructed wetland (CW) built for high organic content piggery wastewater treatment in a cold region. The system consists of four vertical and one horizontal flow subsurface CWs. The wetland was built in 2009 and water quality was monitored from the outset. Average purification efficiency of this system was 95±5, 91±7, 89±8, 70±10, 84±15, 90±6, 99±2, and 93±16% for biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total carbon (TC), total nitrogen (TN), ammonium-N (NH4-N), total phosphorus (TP), total coliform (T. Coliform), and suspended solids (SS), respectively during August 2010-December 2013. Pollutant removal rate was 15±18 g m(-2) d(-1), 49±52 g m(-2) d(-1), 6±4 g m(-2) d(-1), 7±5 g m(-2) d(-1), and 1±1 g m(-2) d(-1) for BOD5, COD, TN, NH4-N, and TP, respectively. The removal efficiency of BOD5, COD, NH4-N, and SS improved yearly since the start of operation. With respect to removal of TN and TP, efficiency improved in the first three years but slightly declined in the fourth year. The system performed well during both warm and cold periods, but was more efficient in the warm period. The nitrate increase may be attributed to a low C/N ratio, due to limited availability of carbon required for denitrification.
Local hyperthermia benefits natural and experimental common colds.
Tyrrell, D.; Barrow, I.; Arthur, J.
1989-01-01
OBJECTIVE--To determine whether inhaling fully humidified air at 43 degrees C gave more benefit to cold sufferers than inhaling air at 30 degrees C. DESIGN--Randomised double blind trial. Setting--General practice and the common cold research unit. SUBJECTS--87 Unselected patients with typical acute nasal and upper respiratory symptoms (general practice study), and 84 volunteers aged 18-50 without a history of chronic or allergic diseases. INTERVENTIONS--Subjects breathed from apparatus delivering 40 litres of room air heated to 43 degrees C or 30 degrees C and fully humidified (relative humidity 100%) per minute. End point--Reduction in severity of disease. MEASUREMENTS and main results--Patients recorded their symptoms (general practice study) and observers recorded symptoms and signs, weight of nasal secretions, isolation of virus, and antibody responses in volunteers. Patients treated for 20 minutes at 43 degrees C had in the succeeding days roughly half the score for symptoms of those treated at 30 degrees C. Volunteers treated for 30 minutes on three occasions when they were starting a cold showed an 18% [corrected] reduction in symptoms. Treatment of volunteers for 20 minutes at the onset of the cold and for 10 minutes on succeeding days showed no difference between 43 degrees C and 30 degrees C. CONCLUSIONS--Nasal hyperthermia can improve the course of a common cold and also give immediate relief of symptoms. PMID:2500196
Cold atoms as a coolant for levitated optomechanical systems
NASA Astrophysics Data System (ADS)
Ranjit, Gambhir; Montoya, Cris; Geraci, Andrew A.
2015-01-01
Optically trapped dielectric objects are well suited for reaching the quantum regime of their center-of-mass motion in an ultrahigh-vacuum environment. We show that ground-state cooling of an optically trapped nanosphere is achievable when starting at room temperature, by sympathetic cooling of a cold-atomic gas optically coupled to the nanoparticle. Unlike cavity cooling in the resolved-sideband limit, this system requires only a modest cavity finesse and it allows the cooling to be turned off, permitting subsequent observation of strongly coupled dynamics between the atoms and sphere. Nanospheres cooled to their quantum ground state could have applications in quantum information science or in precision sensing.
The Fundamental Neutron Physics Beamline at the Spallation Neutron Source.
Greene, Geoffrey; Cianciolo, Vince; Koehler, Paul; Allen, Richard; Snow, William Michael; Huffman, Paul; Gould, Chris; Bowman, David; Cooper, Martin; Doyle, John
2005-01-01
The Spallation Neutron Source (SNS), currently under construction at Oak Ridge National Laboratory with an anticipated start-up in early 2006, will provide the most intense pulsed beams of cold neutrons in the world. At a projected power of 1.4 MW, the time averaged fluxes and fluences of the SNS will approach those of high flux reactors. One of the flight paths on the cold, coupled moderator will be devoted to fundamental neutron physics. The fundamental neutron physics beamline is anticipated to include two beam-lines; a broad band cold beam, and a monochromatic beam of 0.89 nm neutrons for ultracold neutron (UCN) experiments. The fundamental neutron physics beamline will be operated as a user facility with experiment selection based on a peer reviewed proposal process. An initial program of five experiments in neutron decay, hadronic weak interaction and time reversal symmetry violation have been proposed.
Thermal responses from repeated exposures to severe cold with intermittent warmer temperatures.
Ozaki, H; Enomoto-Koshimizu, H; Tochihara, Y; Nakamura, K
1998-09-01
This study was conducted to evaluate physiological reaction and manual performance during exposure to warm (30 degrees C) and cool (10 degrees C) environments after exposure to very low temperatures (-25 degrees C). Furthermore, this experiment was conducted to study whether it is desirable to remove cold-protective jackets in warmer rooms after severe cold exposure. Eight male students remained in an extremely cold room for 20 min, after which they transferred into either the warm room or the cool room for 20 min. This pattern was repeated three times, and the total cold exposure time was 60 min. In the warm and cool rooms, the subjects either removed their cold-protective jackets (Condition A), or wore them continuously (Condition B). Rectal temperature, skin temperatures, manual performance, blood pressure, thermal, comfort and pain sensations were measured during the experiment. The effects of severe cold on almost all measurements in the cool (10 degrees C) environment were greater than those in the warm (30 degrees C) environment under both clothing conditions. The effects of severe cold on all measurements under Condition A except rectal temperature and toe skin temperature were significantly greater than those under Condition B in the cool environment but, not at all differences between Condition A and Condition B in the warm environments were significant. It was recognized that to remove cold-protective jackets in the cool room (10 degrees C) after severe cold exposure promoted the effects of severe cold. When rewarming in the warm resting room (30 degrees C), the physiological and psychological responses and manual performance were not influenced by the presence or absence of cold-protective clothing. These results suggest that it is necessary for workers to make sure to rewarm in the warm room outside of the cold storage and continue to wear cold-protective clothing in the cool room.
Actively controlling coolant-cooled cold plate configuration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
A method is provided to facilitate active control of thermal and fluid dynamic performance of a coolant-cooled cold plate. The method includes: monitoring a variable associated with at least one of the coolant-cooled cold plate or one or more electronic components being cooled by the cold plate; and dynamically varying, based on the monitored variable, a physical configuration of the cold plate. By dynamically varying the physical configuration, the thermal and fluid dynamic performance of the cold plate are adjusted to, for example, optimally cool the one or more electronic components, and at the same time, reduce cooling power consumptionmore » used in cooling the electronic component(s). The physical configuration can be adjusted by providing one or more adjustable plates within the coolant-cooled cold plate, the positioning of which may be adjusted based on the monitored variable.« less
Passive Rocket Diffuser Testing: Reacting Flow Performance of Four Second-Throat Geometries
NASA Technical Reports Server (NTRS)
Jones, Daniel R.; Allgood, Daniel C.; Saunders, Grady P.
2016-01-01
Second-throat diffusers serve to isolate rocket engines from the effects of ambient back pressure. As one of the nation's largest rocket testing facilities, the performance and design limitations of diffusers are of great interest to NASA's Stennis Space Center. This paper describes a series of tests conducted on four diffuser configurations to better understand the effects of inlet geometry and throat area on starting behavior and boundary layer separation. The diffusers were tested for a duration of five seconds with a 1455-pound thrust, LO2/GH2 thruster to ensure they each reached aerodynamic steady state. The effects of a water spray ring at the diffuser exits and a water-cooled deflector plate were also evaluated. Static pressure and temperature measurements were taken at multiple axial locations along the diffusers, and Computational Fluid Dynamics (CFD) simulations were used as a tool to aid in the interpretation of data. The hot combustion products were confirmed to enable the diffuser start condition with tighter second throats than predicted by historical cold-flow data or the theoretical normal shock method. Both aerodynamic performance and heat transfer were found to increase with smaller diffuser throats. Spray ring and deflector cooling water had negligible impacts on diffuser boundary layer separation. CFD was found to accurately capture diffuser shock structures and full-flowing diffuser wall pressures, and the qualitative behavior of heat transfer. However, the ability to predict boundary layer separated flows was not consistent.
47 CFR 2.1055 - Measurements required: Frequency stability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... not more than 10° centigrade through the range. A period of time sufficient to stabilize all of the... incorporating heater type crystal oscillators to be used in mobile stations, for which type acceptance is first... from a cold start and the elapsed time necessary for the frequency to stabilize within the applicable...
47 CFR 2.1055 - Measurements required: Frequency stability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... not more than 10° centigrade through the range. A period of time sufficient to stabilize all of the... incorporating heater type crystal oscillators to be used in mobile stations, for which type acceptance is first... from a cold start and the elapsed time necessary for the frequency to stabilize within the applicable...
47 CFR 2.1055 - Measurements required: Frequency stability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... not more than 10° centigrade through the range. A period of time sufficient to stabilize all of the... incorporating heater type crystal oscillators to be used in mobile stations, for which type acceptance is first... from a cold start and the elapsed time necessary for the frequency to stabilize within the applicable...
47 CFR 2.1055 - Measurements required: Frequency stability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... not more than 10° centigrade through the range. A period of time sufficient to stabilize all of the... incorporating heater type crystal oscillators to be used in mobile stations, for which type acceptance is first... from a cold start and the elapsed time necessary for the frequency to stabilize within the applicable...
47 CFR 2.1055 - Measurements required: Frequency stability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... not more than 10° centigrade through the range. A period of time sufficient to stabilize all of the... incorporating heater type crystal oscillators to be used in mobile stations, for which type acceptance is first... from a cold start and the elapsed time necessary for the frequency to stabilize within the applicable...
Background: Energy's holy grail. [The quest for controlled fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This article presents a brief history of the pursuit and development of fusion as a power source. Starting with the 1950s through the present, the research efforts of the US and other countries is highlighted, including a chronology of hey developments. Other topics discussed include cold fusion and magnetic versus inertial fusion issues.
Career Goal-Based E-Learning Recommendation Using Enhanced Collaborative Filtering and PrefixSpan
ERIC Educational Resources Information Center
Ma, Xueying; Ye, Lu
2018-01-01
This article describes how e-learning recommender systems nowadays have applied different kinds of techniques to recommend personalized learning content for users based on their preference, goals, interests and background information. However, the cold-start problem which exists in traditional recommendation algorithms are still left over in…
Analysis of boron dilution in a four-loop PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, J.G.; Sha, W.T.
1995-12-31
Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plantmore » is at hot standby and the reactor coolant system has been heated up to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated.« less
NASA Astrophysics Data System (ADS)
Leydet, D.; Carlson, A. E.; Sinclair, G.; Teller, J. T.; Breckenridge, A. J.; Caffee, M. W.; Barth, A. M.
2015-12-01
The chronology for the eastern outlets of glacial Lake Agassiz holds important consequences for the cause of Younger Dryas cold event during the last deglaciation. Eastward routing of Lake Agassiz runoff was originally hypothesized to have triggered the Younger Dryas. However, currently the chronology of the eastern outlets is only constrained by minimum-limiting radiocarbon ages that could suggest the eastern outlets were still ice covered at the start of the Younger Dryas at ~12.9 ka BP, requiring a different forcing of this abrupt climate event. Nevertheless, the oldest radiocarbon ages are still consistent with an ice-free eastern outlet at the start of the Younger Dryas. Here we will present preliminary 10-Be cosmogenic surface exposure ages from the North Lake, Flat Rock Lake, glacial Lake Kaministiquia, and Lake Nipigon outlets located near Thunder Bay, Ontario. These ages will date the timing of the deglaciation of the Laurentide ice sheet in the eastern outlet region of glacial Lake Agassiz. This will provide an important constraint for the hypothesized freshwater forcing of the cause of Younger Dryas cold event.
Temperature dependence of standard model CP violation.
Brauner, Tomáš; Taanila, Olli; Tranberg, Anders; Vuorinen, Aleksi
2012-01-27
We analyze the temperature dependence of CP violation effects in the standard model by determining the effective action of its bosonic fields, obtained after integrating out the fermions from the theory and performing a covariant gradient expansion. We find nonvanishing CP violating terms starting at the sixth order of the expansion, albeit only in the C-odd-P-even sector, with coefficients that depend on quark masses, Cabibbo-Kobayashi-Maskawa matrix elements, temperature and the magnitude of the Higgs field. The CP violating effects are observed to decrease rapidly with temperature, which has important implications for the generation of a matter-antimatter asymmetry in the early Universe. Our results suggest that the cold electroweak baryogenesis scenario may be viable within the standard model, provided the electroweak transition temperature is at most of order 1 GeV.
NASA Astrophysics Data System (ADS)
Kumar, S.; Durini, D.; Degenhardt, C.; van Waasen, S.
2018-01-01
Small-angle neutron scattering (SANS) experiments have become one of the most important techniques in the investigation of the properties of material on the atomic scale. Until 2001, nearly exclusively 3He-based detectors were used for neutron detection in these experiments, but due to the scarcity of 3He and its steeply rising price, researchers started to look for suitable alternatives. Scintillation based solid state detectors appeared as a prominent alternative. Silicon photomultipliers (SiPM), having single photon resolution, lower bias voltages compared to photomultiplier tubes (PMT), insensitivity to magnetic fields, low cost, possibility of modular design and higher readout rates, have the potential of becoming a photon detector of choice in scintillator based neutron detectors. The major concerns for utilizing the SiPM technology in this kind of applications are the increase in their noise performance and the decrease in their photon detection efficiency (PDE) due to direct exposure to neutrons. Here, a detailed comparative analysis of the PDE performance in the range between UV and NIR parts of the spectra for three different SiPM technologies, before and after irradiation with cold neutrons, has been carried out. For this investigation, one digital and two analog SiPM arrays were irradiated with 5Å wavelength cold neutrons and up to a dose of 6×1012 n/cm2 at the KWS-1 instrument of the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching, Germany.
Braido, Fulvio; Santus, Pierachille; Corsico, Angelo Guido; Di Marco, Fabiano; Melioli, Giovanni; Scichilone, Nicola; Solidoro, Paolo
2018-01-01
The purposes of this study were development and validation of an expert system (ES) aimed at supporting the diagnosis of chronic obstructive lung disease (COLD). A questionnaire and a WebFlex code were developed and validated in silico. An expert panel pilot validation on 60 cases and a clinical validation on 241 cases were performed. The developed questionnaire and code validated in silico resulted in a suitable tool to support the medical diagnosis. The clinical validation of the ES was performed in an academic setting that included six different reference centers for respiratory diseases. The results of the ES expressed as a score associated with the risk of suffering from COLD were matched and compared with the final clinical diagnoses. A set of 60 patients were evaluated by a pilot expert panel validation with the aim of calculating the sample size for the clinical validation study. The concordance analysis between these preliminary ES scores and diagnoses performed by the experts indicated that the accuracy was 94.7% when both experts and the system confirmed the COLD diagnosis and 86.3% when COLD was excluded. Based on these results, the sample size of the validation set was established in 240 patients. The clinical validation, performed on 241 patients, resulted in ES accuracy of 97.5%, with confirmed COLD diagnosis in 53.6% of the cases and excluded COLD diagnosis in 32% of the cases. In 11.2% of cases, a diagnosis of COLD was made by the experts, although the imaging results showed a potential concomitant disorder. The ES presented here (COLD ES ) is a safe and robust supporting tool for COLD diagnosis in primary care settings.
Amorim, Diana; Puga, Sónia; Bragança, Rui; Braga, António; Pertovaara, Antti; Almeida, Armando; Pinto-Ribeiro, Filipa
2017-06-01
A common and devastating complication of diabetes mellitus is painful diabetic neuropathy (PDN) that can be accompanied by emotional disorders such as depression. A few studies have suggested that minocycline that inhibits microglia may attenuate pain hypersensitivity in PDN. Moreover, a recent study reported that minocycline has an acute antidepressive-like effect in diabetic animals. Here we studied whether (i) prolonged minocycline treatment suppresses pain behaviour in PDN, (ii) the minocycline effect varies with submodality of pain, and (iii) the suppression of pain behaviour by prolonged minocycline treatment is associated with antidepressive-like effect. The experiments were performed in streptozotocin-induced rat model of type-1 diabetes. Pain behaviour was evoked by innocuous (monofilaments) and noxious (paw pressure) mechanical stimulation, innocuous cold (acetone drops) and noxious heat (radiant heat). Depression-like behaviour was assessed using forced swimming test. Minocycline treatment (daily 80mg/kg per os) of three-week duration started four weeks after induction of diabetes. Diabetes induced mechanical allodynia and hyperalgesia, cold allodynia, heat hypoalgesia, and depression-like behaviour. Minocycline treatment significantly attenuated mechanical allodynia and depression-like behaviour, while it failed to produce significant changes in mechanical hyperalgesia, cold allodynia or heat hypoalgesia. The results indicate that prolonged per oral treatment with minocycline has a sustained mechanical antiallodynic and antidepressive-like effect in PDN. These results support the proposal that minocycline might provide a treatment option for attenuating sensory and comorbid emotional symptoms in chronic PDN. Copyright © 2017 Elsevier B.V. All rights reserved.
Thyroid hormone regulates muscle function during cold acclimation in zebrafish (Danio rerio).
Little, Alexander G; Seebacher, Frank
2013-09-15
Thyroid hormone (TH) is a universal regulator of growth, development and metabolism during cold exposure in mammals. In zebrafish (Danio rerio), TH regulates locomotor performance and metabolism during cold acclimation. The influence of TH on locomotor performance may be via its effect on metabolism or, as has been shown in mammals, by modulating muscle phenotypes. Our aim was to determine whether TH influences muscle phenotypes in zebrafish, and whether this could explain changes in swimming capacity in response to thermal acclimation. We used propylthiouracil and iopanoic acid to induce hypothyroidism in zebrafish over a 3-week acclimation period to either 18 or 28°C. To verify that physiological changes following hypothyroid treatment were in fact due to the action of TH, we supplemented hypothyroid fish with 3,5-diiodothryronine (T2) or 3,5,3'-triiodothyronine (T3). Cold-acclimated fish had significantly greater sustained swimming performance (Ucrit) but not burst speed. Greater Ucrit was accompanied by increased tail beat frequency, but there was no change in tail beat amplitude. Hypothyroidism significantly decreased Ucrit and burst performance, as well as tail beat frequency and SERCA activity in cold-acclimated fish. However, myofibrillar ATPase activity increased in cold-acclimated hypothyroid fish. Hypothyroid treatment also decreased mRNA concentrations of myosin heavy chain fast isoforms and SERCA 1 isoform in cold-acclimated fish. SERCA 1 mRNA increased in warm-acclimated hypothyroid fish, and SERCA 3 mRNA decreased in both cold- and warm-acclimated hypothyroid fish. Supplementation with either T2 or T3 restored Ucrit, burst speed, tail beat frequency, SERCA activity and myosin heavy chain and SERCA 1 and 3 mRNA levels of hypothyroid fish back to control levels. We show that in addition to regulating development and metabolism in vertebrates, TH also regulates muscle physiology in ways that affect locomotor performance in fish. We suggest that the role of TH in modulating SERCA1 expression during cold exposure may have predisposed it to regulate endothermic thermogenesis.
Effect of a 5-min cold-water immersion recovery on exercise performance in the heat.
Peiffer, J J; Abbiss, C R; Watson, G; Nosaka, K; Laursen, P B
2010-05-01
This study examined the effect of a 5-min cold-water immersion (14 degrees C) recovery intervention on repeated cycling performance in the heat. 10 male cyclists performed two bouts of a 25-min constant-paced (254 (22) W) cycling session followed by a 4-km time trial in hot conditions (35 degrees C, 40% relative humidity). The two bouts were separated by either 15 min of seated recovery in the heat (control) or the same condition with 5-min cold-water immersion (5th-10th minute), using a counterbalanced cross-over design (CP(1)TT(1) --> CWI or CON --> CP(2)TT(2)). Rectal temperature was measured immediately before and after both the constant-paced sessions and 4-km timed trials. Cycling economy and Vo(2) were measured during the constant-paced sessions, and the average power output and completion times were recorded for each time trial. Compared with control, rectal temperature was significantly lower (0.5 (0.4) degrees C) in cold-water immersion before CP(2) until the end of the second 4-km timed trial. However, the increase in rectal temperature (0.5 (0.2) degrees C) during CP(2) was not significantly different between conditions. During the second 4-km timed trial, power output was significantly greater in cold-water immersion (327.9 (55.7) W) compared with control (288.0 (58.8) W), leading to a faster completion time in cold-water immersion (6.1 (0.3) min) compared with control (6.4 (0.5) min). Economy and Vo(2) were not influenced by the cold-water immersion recovery intervention. 5-min cold-water immersion recovery significantly lowered rectal temperature and maintained endurance performance during subsequent high-intensity exercise. These data indicate that repeated exercise performance in heat may be improved when a short period of cold-water immersion is applied during the recovery period.
Lithium-ion battery structure that self-heats at low temperatures
NASA Astrophysics Data System (ADS)
Wang, Chao-Yang; Zhang, Guangsheng; Ge, Shanhai; Xu, Terrence; Ji, Yan; Yang, Xiao-Guang; Leng, Yongjun
2016-01-01
Lithium-ion batteries suffer severe power loss at temperatures below zero degrees Celsius, limiting their use in applications such as electric cars in cold climates and high-altitude drones. The practical consequences of such power loss are the need for larger, more expensive battery packs to perform engine cold cranking, slow charging in cold weather, restricted regenerative braking, and reduction of vehicle cruise range by as much as 40 per cent. Previous attempts to improve the low-temperature performance of lithium-ion batteries have focused on developing additives to improve the low-temperature behaviour of electrolytes, and on externally heating and insulating the cells. Here we report a lithium-ion battery structure, the ‘all-climate battery’ cell, that heats itself up from below zero degrees Celsius without requiring external heating devices or electrolyte additives. The self-heating mechanism creates an electrochemical interface that is favourable for high discharge/charge power. We show that the internal warm-up of such a cell to zero degrees Celsius occurs within 20 seconds at minus 20 degrees Celsius and within 30 seconds at minus 30 degrees Celsius, consuming only 3.8 per cent and 5.5 per cent of cell capacity, respectively. The self-heated all-climate battery cell yields a discharge/regeneration power of 1,061/1,425 watts per kilogram at a 50 per cent state of charge and at minus 30 degrees Celsius, delivering 6.4-12.3 times the power of state-of-the-art lithium-ion cells. We expect the all-climate battery to enable engine stop-start technology capable of saving 5-10 per cent of the fuel for 80 million new vehicles manufactured every year. Given that only a small fraction of the battery energy is used for self-heating, we envisage that the all-climate battery cell may also prove useful for plug-in electric vehicles, robotics and space exploration applications.
Lithium-ion battery structure that self-heats at low temperatures.
Wang, Chao-Yang; Zhang, Guangsheng; Ge, Shanhai; Xu, Terrence; Ji, Yan; Yang, Xiao-Guang; Leng, Yongjun
2016-01-28
Lithium-ion batteries suffer severe power loss at temperatures below zero degrees Celsius, limiting their use in applications such as electric cars in cold climates and high-altitude drones. The practical consequences of such power loss are the need for larger, more expensive battery packs to perform engine cold cranking, slow charging in cold weather, restricted regenerative braking, and reduction of vehicle cruise range by as much as 40 per cent. Previous attempts to improve the low-temperature performance of lithium-ion batteries have focused on developing additives to improve the low-temperature behaviour of electrolytes, and on externally heating and insulating the cells. Here we report a lithium-ion battery structure, the 'all-climate battery' cell, that heats itself up from below zero degrees Celsius without requiring external heating devices or electrolyte additives. The self-heating mechanism creates an electrochemical interface that is favourable for high discharge/charge power. We show that the internal warm-up of such a cell to zero degrees Celsius occurs within 20 seconds at minus 20 degrees Celsius and within 30 seconds at minus 30 degrees Celsius, consuming only 3.8 per cent and 5.5 per cent of cell capacity, respectively. The self-heated all-climate battery cell yields a discharge/regeneration power of 1,061/1,425 watts per kilogram at a 50 per cent state of charge and at minus 30 degrees Celsius, delivering 6.4-12.3 times the power of state-of-the-art lithium-ion cells. We expect the all-climate battery to enable engine stop-start technology capable of saving 5-10 per cent of the fuel for 80 million new vehicles manufactured every year. Given that only a small fraction of the battery energy is used for self-heating, we envisage that the all-climate battery cell may also prove useful for plug-in electric vehicles, robotics and space exploration applications.
NASA Technical Reports Server (NTRS)
Burbach, T.
1985-01-01
The heat transfer from hot water to a cold copper pipe in laminar and turbulent flow condition is determined. The mean flow through velocity in the pipe, relative test length and initial temperature in the vessel were varied extensively during tests. Measurements confirm Nusselt's theory for large test lengths in laminar range. A new equation is derived for heat transfer for large starting lengths which agrees satisfactorily with measurements for large starting lengths. Test results are compared with the new Prandtl equation for heat transfer and correlated well. Test material for 200- and to 400-diameter test length is represented at four different vessel temperatures.
Cold start characteristics of ethanol as an automobile fuel
Greiner, Leonard
1982-01-01
An alcohol fuel burner and decomposer in which one stream of fuel is preheated by passing it through an electrically heated conduit to vaporize the fuel, the fuel vapor is mixed with air, the air-fuel mixture is ignited and combusted, and the combustion gases are passed in heat exchange relationship with a conduit carrying a stream of fuel to decompose the fuel forming a fuel stream containing hydrogen gas for starting internal combustion engines, the mass flow of the combustion gas being increased as it flows in heat exchange relationship with the fuel carrying conduit, is disclosed.
Hollow-Cathode Source Generates Plasma
NASA Technical Reports Server (NTRS)
Deininger, W. D.; Aston, G.; Pless, L. C.
1989-01-01
Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.
Durability and smart condition assessment of ultra-high performance concrete in cold climates.
DOT National Transportation Integrated Search
2016-12-31
The goals of this study were to develop ecological ultra-high performance concrete (UHPC) with local materials and supplementary cementitious materials and to evaluate the long-term performance of UHPC in cold climates using effective mechanical test...
NASA Technical Reports Server (NTRS)
Melcher, John C.; Morehead, Robert L.
2014-01-01
The project Morpheus liquid oxygen (LOX) / liquid methane (LCH4) main engine is a Johnson Space Center (JSC) designed 5,000 lbf-thrust, 4:1 throttling, pressure-fed cryogenic engine using an impinging element injector design. The engine met or exceeded all performance requirements without experiencing any in- ight failures, but the engine exhibited acoustic-coupled combustion instabilities during sea-level ground-based testing. First tangential (1T), rst radial (1R), 1T1R, and higher order modes were triggered by conditions during the Morpheus vehicle derived low chamber pressure startup sequence. The instability was never observed to initiate during mainstage, even at low power levels. Ground-interaction acoustics aggravated the instability in vehicle tests. Analysis of more than 200 hot re tests on the Morpheus vehicle and Stennis Space Center (SSC) test stand showed a relationship between ignition stability and injector/chamber pressure. The instability had the distinct characteristic of initiating at high relative injection pressure drop at low chamber pressure during the start sequence. Data analysis suggests that the two-phase density during engine start results in a high injection velocity, possibly triggering the instabilities predicted by the Hewitt stability curves. Engine ignition instability was successfully mitigated via a higher-chamber pressure start sequence (e.g., 50% power level vs 30%) and operational propellant start temperature limits that maintained \\cold LOX" and \\warm methane" at the engine inlet. The main engine successfully demonstrated 4:1 throttling without chugging during mainstage, but chug instabilities were observed during some engine shutdown sequences at low injector pressure drop, especially during vehicle landing.
Seizing market shaping opportunities for vaccine cold chain equipment.
Azimi, Tara; Franzel, Lauren; Probst, Nina
2017-04-19
Gavi, the Vaccine Alliance, supports immunisation programmes in eligible countries to reach children with lifesaving vaccines. Dramatic improvement in the scale and performance of current cold chain systems is required to extend the reach of immunisation services - especially for children living in remote locations - to advance progress towards full vaccine coverage. Achieving these improvements will require a healthier market for cold chain equipment where the products meet user needs, are sustainably priced, and are available in sufficient quantities to meet demand. Yet evidence suggests that the cold chain market has suffered from several failures including limited demand visibility, fragmented procurement, and insufficient information exchange between manufacturers and buyers on needs and equipment performance. One of Gavi's strategic goals is to shape markets for vaccines and other immunisation products, including cold chain equipment and in 2015, Gavi created a new mechanism - the Cold Chain Equipment (CCE) Optimisation Platform - to strengthen country cold chain systems by offering financial support and incentives for higher performing CCE. The main objective of the CCE Platform is to get more equipment that is efficient, sustainable, and better performing deployed to every health facility where it is required at an affordable price. To achieve these objectives, Gavi is putting in place tested market shaping approaches and tools adapted for the CCE market: the development of market strategies or 'roadmaps'; improvement of product performance through the development of target product profiles (TPPs); strategic engagement with CCE manufacturers and countries to enhance information sharing; and tailoring procurement tactics to the CCE market. These approaches and tools will allow for increased demand and supply of higher-performing, cost-effective and quality products. By strengthening immunisation systems with improved cold chain equipment, Gavi countries can begin to address the underlying problems limiting vaccine availability and improve the coverage and equity of vaccines. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Cecere, Anselmo; De Cristofaro, Davide; Savino, Raffaele; Ayel, Vincent; Sole-Agostinelli, Thibaud; Marengo, Marco; Romestant, Cyril; Bertin, Yves
2018-06-01
A Flat Plate Pulsating Heat Pipe (FPPHP) filled with an ordinary liquid (water) and a self-rewetting mixture (dilutes aqueous solutions of long-chain alcohols with unusual surface tension behavior) is investigated under variable gravity conditions on board a 'Zero-g' plane during the 65th Parabolic Flight Campaign of the European Space Agency. The FPPHP thermal performance in terms of evaporator and condenser temperatures, start-up levels and flow regimes is characterized for the two working fluids and a power input ranging from 0 to 200 W (up to 17 W/cm2 at the heater/evaporator wall interface). The experimental set-up also includes a transparent plate enabling the visualization of the oscillating flow patterns during the experiments. For a low power input (4 W/cm2), the pulsating heat pipe filled with pure water is not able to work under low-g conditions, because the evaporator immediately exhibits dry-out conditions and the fluid oscillations stops, preventing heat transfer between the hot and cold side and resulting in a global increase of the temperatures. On the other hand, the FPPHP filled with the self-rewetting fluid runs also during the microgravity phase. The liquid rewets several times the evaporator zone triggering the oscillatory regime. The self-rewetting fluid helps both the start-up and the thermal performance of the FPPHP in microgravity conditions.
EVermont Renewable Hydrogen Production and Transportation Fueling System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garabedian, Harold T.
2008-03-30
A great deal of research funding is being devoted to the use of hydrogen for transportation fuel, particularly in the development of fuel cell vehicles. When this research bears fruit in the form of consumer-ready vehicles, will the fueling infrastructure be ready? Will the required fueling systems work in cold climates as well as they do in warm areas? Will we be sure that production of hydrogen as the energy carrier of choice for our transit system is the most energy efficient and environmentally friendly option? Will consumers understand this fuel and how to handle it? Those are questions addressedmore » by the EVermont Wind to Wheels Hydrogen Project: Sustainable Transportation. The hydrogen fueling infrastructure consists of three primary subcomponents: a hydrogen generator (electrolyzer), a compression and storage system, and a dispenser. The generated fuel is then used to provide transportation as a motor fuel. EVermont Inc., started in 1993 by then governor Howard Dean, is a public-private partnership of entities interested in documenting and advancing the performance of advanced technology vehicles that are sustainable and less burdensome on the environment, especially in areas of cold climates, hilly terrain and with rural settlement patterns. EVermont has developed a demonstration wind powered hydrogen fuel producing filling system that uses electrolysis, compression to 5000 psi and a hydrogen burning vehicle that functions reliably in cold climates. And that fuel is then used to meet transportation needs in a hybrid electric vehicle whose internal combustion engine has been converted to operate on hydrogen Sponsored by the DOE EERE Hydrogen, Fuel Cells & Infrastructure Technologies (HFC&IT) Program, the purpose of the project is to test the viability of sustainably produced hydrogen for use as a transportation fuel in a cold climate with hilly terrain and rural settlement patterns. Specifically, the project addresses the challenge of building a renewable transportation energy capable system. The prime energy for this project comes from an agreement with a wind turbine operator.« less
Cold Stress and the Cold Pressor Test
ERIC Educational Resources Information Center
Silverthorn, Dee U.; Michael, Joel
2013-01-01
Temperature and other environmental stressors are known to affect blood pressure and heart rate. In this activity, students perform the cold pressor test, demonstrating increased blood pressure during a 1- to 2-min immersion of one hand in ice water. The cold pressor test is used clinically to evaluate autonomic and left ventricular function. This…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, E.; Gonder, J.; Lopp, S.
It is widely understood that cold-temperature engine operation negatively impacts vehicle fuel use due to a combination of increased friction (high-viscosity engine oil) and temporary enrichment (accelerated catalyst heating). However, relatively little effort has been dedicated to thoroughly quantifying these impacts across a large number of driving cycles and ambient conditions. This work leverages high-quality dynamometer data collected at various ambient conditions to develop a modeling framework for quantifying engine cold-start fuel penalties over a wide array of real-world usage profiles. Additionally, mitigation strategies including energy retention and exhaust heat recovery are explored with benefits quantified for each approach.
NASA Astrophysics Data System (ADS)
Grygar, J.
2018-04-01
Although infrared radiation was described by W. Herschel already in 1800, technical problems delayed its use in astronomy for 160 years. After the invention of a sensitive bolometer and semiconducting CCD arrays for very wide infrared window the progress in the field accelerated. Many high-altitude observatories started their work in the last three decades of XXth century and since 1983 space observatories became most important due to the fact that infrared radiation penetrates through opaque cold shells. Moreover, cosmological expansion of the Universe shifts the maximum of spectral energy of distant hot objects from ultraviolet to near infrared region. Infrared astronomy is also essential for improving our knowledge of the cold universe, particularly for studies about the birth of stars, planetary systems and galaxies.
Kurepin, Leonid V.; Dahal, Keshav P.; Savitch, Leonid V.; Singh, Jas; Bode, Rainer; Ivanov, Alexander G.; Hurry, Vaughan; Hüner, Norman P. A.
2013-01-01
Cold acclimation of winter cereals and other winter hardy species is a prerequisite to increase subsequent freezing tolerance. Low temperatures upregulate the expression of C-repeat/dehydration-responsive element binding transcription factors (CBF/DREB1) which in turn induce the expression of COLD-REGULATED (COR) genes. We summarize evidence which indicates that the integration of these interactions is responsible for the dwarf phenotype and enhanced photosynthetic performance associated with cold-acclimated and CBF-overexpressing plants. Plants overexpressing CBFs but grown at warm temperatures mimic the cold-tolerant, dwarf, compact phenotype; increased photosynthetic performance; and biomass accumulation typically associated with cold-acclimated plants. In this review, we propose a model whereby the cold acclimation signal is perceived by plants through an integration of low temperature and changes in light intensity, as well as changes in light quality. Such integration leads to the activation of the CBF-regulon and subsequent upregulation of COR gene and GA 2-oxidase (GA2ox) expression which results in a dwarf phenotype coupled with increased freezing tolerance and enhanced photosynthetic performance. We conclude that, due to their photoautotrophic nature, plants do not rely on a single low temperature sensor, but integrate changes in light intensity, light quality, and membrane viscosity in order to establish the cold-acclimated state. CBFs appear to act as master regulators of these interconnecting sensing/signaling pathways. PMID:23778089
Self-adaptive thermal management - the fundamentals and applications in Li-polymer batteries
NASA Astrophysics Data System (ADS)
Geng, Xiaobao
The thermal management systems for electronic devices and their power sources are facing increasing challenge to accommodate the ever-changing environmental and operational conditions. The conventional thermal management systems, with a predominant focus on cooling, are often not sufficient in those cases. In addition, to support miniaturization, complex systems and broader applications (e.g., space and military), the thermal management system often needs to be compatible with smaller device and their fabrication processes, dissipate heat efficiently for localized heat spot, and meet the requirement of light weight and low power consumption. In order to address such issues, a self-adaptive thermal switch array (TSA) is proposed based on microelectromechanical systems (MEMS) technology which has the capability automatically change its thermal conductance according to the environmental and operational conditions. This TSA was actuated by low melting alloy (LMA) with neither control unit nor parasitic energy consumption. The idea has been first demonstrated by a prototype device with the stabilization temperatures under various power inputs investigated both experimentally and theoretically. When the power input was changed from 3.8W to 5.8W, the stabilization temperature of the device was increased only by 2.5°C due to the stabilization effect of TSA. The experimental data were found in good agreement with their theoretical value. Based on the theoretical model, two types of TSA, namely high-on and low-off, were further developed to increase on-state thermal conductance and decrease off-state thermal conductance, respectively. Compared with the low-off TSA, the high-on TSA can more efficiently cool the devices and stabilize their temperature at a value closer to the melting point of LMA even under higher power inputs. On the other hand, the startup time and energy consumption were significantly reduced with the low-off TSA design due to the enhanced off-state thermal insulation, making them more suitable for cold start applications. A few key design factors have been identified to increase the on-state thermal conductance, reduce the off-state thermal conductance and enhance their ratio (switching ratio). The TSAs were then applied to a Li-polymer battery stack to demonstrate the self-adaptive thermal management capability. When cold-started from -10°C, the TSA-regulated battery stack reached 20°C in ~10min. The operational temperature was sustained with a moderate discharge current until depletion, while maintaining a fairly uniform temperate distribution within the battery stack. Compared with the open-cooling case, the performance of the Li-polymer battery was significantly improved by TSA-regulated thermal management. The capacity and output energy were increased by 16% and 23%, respectively. With the low-off TSA, the cold-start time has been shortened to ~ 7min, while the capacity and output energy of battery stack were increased by 18% and 27%, respectively, as compared to open-cooling case. The promising results have also paved the way for improving the performance of self-adaptive thermal management through the key design parameters.
Cold Exposure Exacerbates the Development of Diabetic Polyneuropathy in the Rat
Kasselman, Lora J.; Veves, Aristidis; Gibbons, Christopher H.; Rutkove, Seward B.
2009-01-01
Diabetic polyneuropathy (DPN) and cold-induced nerve injury share several pathogenic mechanisms. This study explores whether cold exposure contributes to the development of DPN. Streptozotocin-induced diabetic rats and controls were exposed to a room temperature (23°C) or cold environment (10°C). H-reflex, tail and sciatic motor, and sensory nerve conduction studies were performed. Analyses of sural nerve, intraepidermal nerve fibers, and skin and nerve nitrotyrosine ELISAs were performed. Diabetic animals exposed to a cold environment had an increased H-reflex four weeks earlier than diabetic room temperature animals (P = .03). Cold-exposed diabetic animals also had greater reduction in motor conduction velocities at 20 weeks (P = .017), decreased skin nerve fiber density (P = .037), and increased skin nitrotyrosine levels (P = .047). Cold exposure appears to hasten the development of DPN in the rat STZ model of diabetes. These findings support that further study into the relationship between ambient temperature and DPN is warranted. PMID:20130819
40 CFR 86.1111-87 - Test procedures for PCA testing.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in paragraph (a) of § 86.133. (v) The manufacturer may substitute slave tires for the drive wheel... same size as the drive wheel tires. (vi) The cold start exhaust emission test described in § 86.137... well as the likelihood that similar settings will occur on in-use heavy-duty engines or light-duty...
Systems and methods to mitigate NO.sub.x and HC emissions
Gupta, Aniket; Cunningham, Michael J.; Ruth, Michael J.; Chilumukuru, Krishna P.
2017-06-14
Systems and methods are provided for managing low temperature NO.sub.x and HC emissions, such as during a cold start of an internal combustion engine. The systems and methods include storing NO.sub.x and HC emissions at low temperatures and passively releasing and treating these emissions as the temperature of the exhaust system increases.
Induction of Colon Cancer in Mice with 1,2-Dimethylhydrazine.
Gurley, Kay E; Moser, Russell D; Kemp, Christopher J
2015-09-01
In this protocol, colon cancer is induced in mice through a series of injections with 1,2-dimethylhydrazine. Mice will develop primarily colon tumors starting at about 3 mo after the first injection. Tumors in the lung, uterus, and small intestine may also be seen, as well as lymphomas. © 2015 Cold Spring Harbor Laboratory Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Mike
2015-02-01
This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.
Improved hybrid information filtering based on limited time window
NASA Astrophysics Data System (ADS)
Song, Wen-Jun; Guo, Qiang; Liu, Jian-Guo
2014-12-01
Adopting the entire collecting information of users, the hybrid information filtering of heat conduction and mass diffusion (HHM) (Zhou et al., 2010) was successfully proposed to solve the apparent diversity-accuracy dilemma. Since the recent behaviors are more effective to capture the users' potential interests, we present an improved hybrid information filtering of adopting the partial recent information. We expand the time window to generate a series of training sets, each of which is treated as known information to predict the future links proven by the testing set. The experimental results on one benchmark dataset Netflix indicate that by only using approximately 31% recent rating records, the accuracy could be improved by an average of 4.22% and the diversity could be improved by 13.74%. In addition, the performance on the dataset MovieLens could be preserved by considering approximately 60% recent records. Furthermore, we find that the improved algorithm is effective to solve the cold-start problem. This work could improve the information filtering performance and shorten the computational time.
Improving information filtering via network manipulation
NASA Astrophysics Data System (ADS)
Zhang, Fuguo; Zeng, An
2012-12-01
The recommender system is a very promising way to address the problem of overabundant information for online users. Although the information filtering for the online commercial systems has received much attention recently, almost all of the previous works are dedicated to design new algorithms and consider the user-item bipartite networks as given and constant information. However, many problems for recommender systems such as the cold-start problem (i.e., low recommendation accuracy for the small-degree items) are actually due to the limitation of the underlying user-item bipartite networks. In this letter, we propose a strategy to enhance the performance of the already existing recommendation algorithms by directly manipulating the user-item bipartite networks, namely adding some virtual connections to the networks. Numerical analyses on two benchmark data sets, MovieLens and Netflix, show that our method can remarkably improves the recommendation performance. Specifically, it not only improves the recommendations accuracy (especially for the small-degree items), but also helps the recommender systems generate more diverse and novel recommendations.
Evaluation of cold mixes for winter pothole repair.
DOT National Transportation Integrated Search
1995-01-01
This study was conducted to evaluate the performance of 13 proprietary cold-mix patching materials, 4 of which are currently approved under a Virginia Department of Transportation (VDOT) Special Provision for High Quality Cold Patching Materials. Col...
Cold habituation does not improve manual dexterity during rest and exercise in 5 °C
NASA Astrophysics Data System (ADS)
Muller, Matthew D.; Seo, Yongsuk; Kim, Chul-Ho; Ryan, Edward J.; Pollock, Brandon S.; Burns, Keith J.; Glickman, Ellen L.
2014-04-01
When exposed to a cold environment, a barehanded person experiences pain, cold sensation, and reduced manual dexterity. Both acute (e.g. exercise) and chronic (e.g. cold acclimatization or habituation) processes might lessen these negative effects. The purpose of this experiment was to determine the effect of cold habituation on physiology, perception, and manual dexterity during rest, exercise, and recovery in 5 °C. Six cold weather athletes (CWA) and eight non habituated men (NON) volunteered to participate in a repeated measures cross-over design. The protocol was conducted in 5 °C and was 90 min of resting cold exposure, 30 min of cycle ergometry exercise (50 % VO2 peak), and 60 min of seated recovery. Core and finger skin temperature, metabolic rate, Purdue Pegboard dexterity performance, hand pain, thermal sensation, and mood were quantified. Exercise-induced finger rewarming (EIFRW) was calculated for each hand. During 90 min of resting exposure to 5 °C, the CWA had a smaller reduction in finger temperature, a lower metabolic rate, less hand pain, and less negative mood. Despite this cold habituation, dexterity performance was not different between groups. In response to cycle ergometry, EIFRW was greater in CWA (~12 versus 7 °C) and occurred at lower core temperatures (37.02 versus 37.31 °C) relative to NON but dexterity was not greater during post-exercise recovery. The current data indicate that cold habituated men (i.e., CWA) do not perform better on the Purdue Pegboard during acute cold exposure. Furthermore, despite augmented EIFRW in CWA, dexterity during post-exercise recovery was similar between groups.
Coughlin, David J; Shiels, Lisa P; Nuthakki, Seshuvardhan; Shuman, Jacie L
2016-06-01
Rainbow smelt (Osmerus mordax), a eurythermal fish, live in environments from -1.8 to 20°C, with some populations facing substantial annual variation in environmental temperature. These different temperature regimes pose distinct challenges to locomotion by smelt. Steady swimming performance, red muscle function and muscle myosin content were examined to assess the prediction that cold acclimation by smelt will lead to improved steady swimming performance and that any performance shift will be associated with changes in red muscle function and in its myosin heavy chain composition. Cold acclimated (4°C) smelt had a faster maximum steady swimming speed and swam with a higher tailbeat frequency than warm acclimated (10°C) smelt when tested at the same temperature (10°C). Muscle mechanics experiments demonstrated faster contractile properties in the cold acclimated fish when tested at 10°C. The red muscle of cold acclimated smelt had a shorter twitch times, a shorter relaxation times and a higher maximum shortening velocity. In addition, red muscle from cold acclimated fish displayed reduced thermal sensitivity to cold, maintaining higher force levels at 4°C compared to red muscle from warm acclimated fish. Immunohistochemistry suggests shifts in muscle myosin composition and a decrease in muscle cross-sectional area with cold acclimation. Dot blot analysis confirmed a shift in myosin content. Rainbow smelt do show a significant thermal acclimation response to cold. An examination of published values of maximum muscle shortening velocity in fishes suggests that smelt are particularly well suited to high levels of activity in very cold water. Copyright © 2016 Elsevier Inc. All rights reserved.
Improving cold chain systems: Challenges and solutions.
Ashok, Ashvin; Brison, Michael; LeTallec, Yann
2017-04-19
While a number of new vaccines have been rolled out across the developing world (with more vaccines in the pipeline), cold chain systems are struggling to efficiently support national immunization programs in ensuring the availability of safe and potent vaccines. This article reflects on the Clinton Health Access Initiative, Inc. (CHAI) experience working since 2010 with national immunization programs and partners to improve vaccines cold chains in 10 countries-Ethiopia, Nigeria, Kenya, Malawi, Tanzania, Uganda, Cameroon, Mozambique, Lesotho and India - to identify the root causes and solutions for three common issues limiting cold chain performance. Key recommendations include: Collectively, the solutions detailed in this article chart a path to substantially improving the performance of the cold chain. Combined with an enabling global and in-country environment, it is possible to eliminate cold chain issues as a substantial barrier to effective and full immunization coverage over the next few years. Copyright © 2017. Published by Elsevier Ltd.
Development of Hot and Cold Executive Function in Boys and Girls With ADHD.
Skogli, Erik Winther; Andersen, Per Normann; Hovik, Kjell Tore; Øie, Merete
2017-02-01
To investigate the development of executive function with pronounced emotional salience (hot EF) and less pronounced emotional salience (cold EF) in boys and girls with ADHD relative to typically developing (TD) children. Seventy-five children with ADHD and 47 TD children were assessed with hot and cold EF tests at baseline and after 2 years. Despite considerable maturation, the ADHD group remained impaired on all cold EF tests relative to TD children after 2 years. There was no effect of gender on cold EF test results. Females with ADHD outperformed TD counterparts on hot EF at baseline. Females with ADHD showed deteriorating hot EF performance, while TD counterparts showed improved hot EF performance across time. Enduring cold EF impairments after 2 years may reflect stable phenotypic traits in children with ADHD. Results indicate divergent developmental trajectories of hot EF in girls with ADHD relative to TD counterparts.
1980-11-01
acket (E/AP) and to assess performance and physiological effects of t he ration at two different ca loric levels. During a f ive-day exercise in a...PACKET FIELD FEEDING RAT IONS DIET(S) PHYSIOLOG ICAL EMERGENCY RATIONS COMPRESSED FOODS TESTS FREEZE DRIED FOODS COLD WEATH ER PERFORMANCE...cold-weather climate, one group of Marines was issued the standard C ration (3550 kca l) while half of a second group were issued one E/AP per day
Evaluation of Neutron Radiography Reactor LEU-Core Start-Up Measurements
Bess, John D.; Maddock, Thomas L.; Smolinski, Andrew T.; ...
2014-11-04
Benchmark models were developed to evaluate the cold-critical start-up measurements performed during the fresh core reload of the Neutron Radiography (NRAD) reactor with Low Enriched Uranium (LEU) fuel. Experiments include criticality, control-rod worth measurements, shutdown margin, and excess reactivity for four core loadings with 56, 60, 62, and 64 fuel elements. The worth of four graphite reflector block assemblies and an empty dry tube used for experiment irradiations were also measured and evaluated for the 60-fuel-element core configuration. Dominant uncertainties in the experimental k eff come from uncertainties in the manganese content and impurities in the stainless steel fuel claddingmore » as well as the 236U and erbium poison content in the fuel matrix. Calculations with MCNP5 and ENDF/B-VII.0 neutron nuclear data are approximately 1.4% (9σ) greater than the benchmark model eigenvalues, which is commonly seen in Monte Carlo simulations of other TRIGA reactors. Simulations of the worth measurements are within the 2σ uncertainty for most of the benchmark experiment worth values. The complete benchmark evaluation details are available in the 2014 edition of the International Handbook of Evaluated Reactor Physics Benchmark Experiments.« less
Evaluation of Neutron Radiography Reactor LEU-Core Start-Up Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bess, John D.; Maddock, Thomas L.; Smolinski, Andrew T.
Benchmark models were developed to evaluate the cold-critical start-up measurements performed during the fresh core reload of the Neutron Radiography (NRAD) reactor with Low Enriched Uranium (LEU) fuel. Experiments include criticality, control-rod worth measurements, shutdown margin, and excess reactivity for four core loadings with 56, 60, 62, and 64 fuel elements. The worth of four graphite reflector block assemblies and an empty dry tube used for experiment irradiations were also measured and evaluated for the 60-fuel-element core configuration. Dominant uncertainties in the experimental k eff come from uncertainties in the manganese content and impurities in the stainless steel fuel claddingmore » as well as the 236U and erbium poison content in the fuel matrix. Calculations with MCNP5 and ENDF/B-VII.0 neutron nuclear data are approximately 1.4% (9σ) greater than the benchmark model eigenvalues, which is commonly seen in Monte Carlo simulations of other TRIGA reactors. Simulations of the worth measurements are within the 2σ uncertainty for most of the benchmark experiment worth values. The complete benchmark evaluation details are available in the 2014 edition of the International Handbook of Evaluated Reactor Physics Benchmark Experiments.« less
Book, Emily K; Snow, Richard; Long, Thomas; Fang, Tiegang; Baldauf, Richard
2015-06-01
Emissions tests were conducted on two medium heavy-duty diesel trucks equipped with a particulate filter (DPF), with one vehicle using a NOx absorber and the other a selective catalytic reduction (SCR) system for control of nitrogen oxides (NOx). Both vehicles were tested with two different fuels (ultra-low-sulfur diesel [ULSD] and biodiesel [B20]) and ambient temperatures (70ºF and 20ºF), while the truck with the NOx absorber was also operated at two loads (a heavy weight and a light weight). The test procedure included three driving cycles, a cold start with low transients (CSLT), the federal heavy-duty urban dynamometer driving schedule (UDDS), and a warm start with low transients (WSLT). Particulate matter (PM) emissions were measured second-by-second using an Aethalometer for black carbon (BC) concentrations and an engine exhaust particle sizer (EEPS) for particle count measurements between 5.6 and 560 nm. The DPF/NOx absorber vehicle experienced increased BC and particle number concentrations during cold starts under cold ambient conditions, with concentrations two to three times higher than under warm starts at higher ambient temperatures. The average particle count for the UDDS showed an opposite trend, with an approximately 27% decrease when ambient temperatures decreased from 70ºF to 20ºF. This vehicle experienced decreased emissions when going from ULSD to B20. The DPF/SCR vehicle tested had much lower emissions, with many of the BC and particle number measurements below detectable limits. However, both vehicles did experience elevated emissions caused by DPF regeneration. All regeneration events occurred during the UDDS cycle. Slight increases in emissions were measured during the WSLT cycles after the regeneration. However, the day after a regeneration occurred, both vehicles showed significant increases in particle number and BC for the CSLT drive cycle, with increases from 93 to 1380% for PM number emissions compared with tests following a day with no regeneration. The use of diesel particulate filters (DPFs) on trucks is becoming more common throughout the world. Understanding how DPFs affect air pollution emissions under varying operating conditions will be critical in implementing effective air quality standards. This study evaluated particulate matter (PM) and black carbon (BC) emissions with two DPF-equipped heavy-duty diesel trucks operating on conventional fuel and a biodiesel fuel blend at varying ambient temperatures, loads, and drive cycles.
Effectiveness of water immersion on postmatch recovery in elite professional footballers.
Elias, George P; Wyckelsma, Victoria L; Varley, Matthew C; McKenna, Michael J; Aughey, Robert J
2013-05-01
The efficacy of a single exposure to 14 min of contrast water therapy (CWT) or cold-water immersion (COLD) on recovery postmatch in elite professional footballers was investigated. Twenty-four elite footballers participated in a match followed by 1 of 3 recovery interventions. Recovery was monitored for 48 h postmatch. Repeat-sprint ability (6 × 20-m), static and countermovement jump performance, perceived soreness, and fatigue were measured prematch and immediately, 24 h, and 48 h after the match. Soreness and fatigue were also measured 1 h postmatch. Postmatch, players were randomly assigned to complete passive recovery (PAS; n = 8), COLD (n = 8), or CWT (n = 8). Immediately postmatch, all groups exhibited similar psychometric and performance decrements, which persisted for 48 h only in the PAS group. Repeat-sprinting performance remained slower at 24 and 48 h for PAS (3.9% and 2.0%) and CWT (1.6% and 0.9%) but was restored by COLD (0.2% and 0.0%). Soreness after 48 h was most effectively attenuated by COLD (ES 0.59 ± 0.10) but remained elevated for CWT (ES 2.39 ± 0.29) and PAS (ES 4.01 ± 0.97). Similarly, COLD more successfully reduced fatigue after 48 h (ES 1.02 ± 0.72) than did CWT (ES 1.22 ± 0.38) and PAS (ES 1.91 ± 0.67). Declines in static and countermovement jump were ameliorated best by COLD. An elite professional football match results in prolonged physical and psychometric deficits for 48 h. COLD was more successful at restoring physical performance and psychometric measures than CWT, with PAS being the poorest.
Farstad, Marit; Kvalheim, Venny Lise; Husby, Paul
2005-08-01
Hypothermic cardiopulmonary bypass is associated with increased fluid extravasation. This study aimed to compare whether iso-oncotic priming solutions, in contrast to crystalloids, could reduce the cold-induced fluid extravasation during cardiopulmonary bypass in piglets. Three groups were studied: the control group (CT group; n = 10), the albumin group (Alb group; n = 7), and the hydroxyethyl starch group (HES group; n = 7). Prime (1000 mL) and supplemental fluid were acetated Ringer solution, 4% albumin, and 6% hydroxyethyl starch, respectively. After 1 hour of normothermic cardiopulmonary bypass, hypothermic cardiopulmonary bypass (cooling to 28 degrees C within 15 minutes) was initiated and continued to 90 minutes. Fluid needs, plasma volume, changes in colloid osmotic pressure in plasma and interstitial fluid, hematocrit levels, and tissue water content were recorded, and protein masses and fluid extravasation rates were calculated. Colloid osmotic pressure in plasma decreased immediately after the start of cardiopulmonary bypass in the CT group but remained stable in the Alb and HES groups. Colloid osmotic pressure in interstitial fluid tended to decrease in the CT group and remained unchanged in the Alb group, whereas a slight increase was observed in the HES group. Immediately after the start of cooling, fluid extravasation rates increased from 0.15 +/- 0.10 to 0.64 +/- 0.12 mL . kg -1 . min -1 in the CT group, whereas no such increase was observed in the Alb and HES groups. The changes in fluid extravasation rates were reflected by corresponding changes in tissue water content. The use of albumin or hydroxyethyl starch as prime to preserve the colloid osmotic pressure during cardiopulmonary bypass causes a reduction in the cold-induced fluid extravasation compared with that seen with crystalloids. Albumin seems more effective than hydroxyethyl starch to limit cold-induced fluid shifts during cardiopulmonary bypass.
Jana, Saumyadeep; Overman, Nicole; Varga, Tamas; ...
2017-09-25
Here, the effect of sub-eutectoid heat treatment on the phase transformation behavior in rolled U-10 wt.% Mo (U10Mo) foils was systematically investigated. The as-cast 5 mm thick foils were initially homogenized at 900 °C for 48 h and were hot rolled to 2 mm and later cold rolled down to 0.2 mm. Three starting microstructures were evaluated: (i) hot + cold-rolled to 0.2 mm (as-rolled condition), (ii) hot + cold-rolled to 0.2 mm + annealed at 700 °C for 1 h, and (iii) hot + cold-rolled to 0.2 mm + annealed at 1000 °C for 60 h. Annealing of as-rolledmore » materials at 700 °C resulted in small grain size (15 ± 9 μm average grain size), while annealing at 1000 °C led to very large grains (156 ± 118 μm average grain size) in rolled U10Mo foils. Later the samples were subjected to sub-eutectoid heat-treatment temperatures of 550 °C, 500 °C, and 400 °C for different durations of time starting from 1 h up to 100 h. U10Mo rolled foils went through various degrees of decomposition when subjected to the sub-eutectoid heat-treatment step and formed a lamellar microstructure through a cellular reaction mostly along the previous γ-UMo grain boundaries. The least amount of cellular reaction was observed in the large-grain microstructure at all temperatures. Conversely, a substantial amount of cellular reaction was observed in both the as-rolled and the small-grain microstructure. After 100 h of heat treatment at 500 °C, the volume fraction of the lamellar phase was found to be 4%, 22%, and 82% in large-grain, as-rolled, and small-grain samples, respectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jana, Saumyadeep; Overman, Nicole; Varga, Tamas
Here, the effect of sub-eutectoid heat treatment on the phase transformation behavior in rolled U-10 wt.% Mo (U10Mo) foils was systematically investigated. The as-cast 5 mm thick foils were initially homogenized at 900 °C for 48 h and were hot rolled to 2 mm and later cold rolled down to 0.2 mm. Three starting microstructures were evaluated: (i) hot + cold-rolled to 0.2 mm (as-rolled condition), (ii) hot + cold-rolled to 0.2 mm + annealed at 700 °C for 1 h, and (iii) hot + cold-rolled to 0.2 mm + annealed at 1000 °C for 60 h. Annealing of as-rolledmore » materials at 700 °C resulted in small grain size (15 ± 9 μm average grain size), while annealing at 1000 °C led to very large grains (156 ± 118 μm average grain size) in rolled U10Mo foils. Later the samples were subjected to sub-eutectoid heat-treatment temperatures of 550 °C, 500 °C, and 400 °C for different durations of time starting from 1 h up to 100 h. U10Mo rolled foils went through various degrees of decomposition when subjected to the sub-eutectoid heat-treatment step and formed a lamellar microstructure through a cellular reaction mostly along the previous γ-UMo grain boundaries. The least amount of cellular reaction was observed in the large-grain microstructure at all temperatures. Conversely, a substantial amount of cellular reaction was observed in both the as-rolled and the small-grain microstructure. After 100 h of heat treatment at 500 °C, the volume fraction of the lamellar phase was found to be 4%, 22%, and 82% in large-grain, as-rolled, and small-grain samples, respectively.« less
Physiological responses to acute cold exposure in young lean men
Martinez-Tellez, Borja; Sanchez-Delgado, Guillermo; A. Alcantara, Juan M.; Acosta-Manzano, Pedro; Morales-Artacho, Antonio J.; R. Ruiz, Jonatan
2018-01-01
The aim of this study was to comprehensively describe the physiological responses to an acute bout of mild cold in young lean men (n = 11, age: 23 ± 2 years, body mass index: 23.1 ± 1.2 kg/m2) to better understand the underlying mechanisms of non-shivering thermogenesis and how it is regulated. Resting energy expenditure, substrate metabolism, skin temperature, thermal comfort perception, superficial muscle activity, hemodynamics of the forearm and abdominal regions, and heart rate variability were measured under warm conditions (22.7 ± 0.2°C) and during an individualized cooling protocol (air-conditioning and water cooling vest) in a cold room (19.4 ± 0.1°C). The temperature of the cooling vest started at 16.6°C and decreased ~ 1.4°C every 10 minutes until participants shivered (93.5 ± 26.3 min). All measurements were analysed across 4 periods: warm period, at 31% and at 64% of individual´s cold exposure time until shivering occurred, and at the shivering threshold. Energy expenditure increased from warm period to 31% of cold exposure by 16.7% (P = 0.078) and to the shivering threshold by 31.7% (P = 0.023). Fat oxidation increased by 72.6% from warm period to 31% of cold exposure (P = 0.004), whereas no changes occurred in carbohydrates oxidation. As shivering came closer, the skin temperature and thermal comfort perception decreased (all P<0.05), except in the supraclavicular skin temperature, which did not change (P>0.05). Furthermore, the superficial muscle activation increased at the shivering threshold. It is noteworthy that the largest physiological changes occurred during the first 30 minutes of cold exposure, when the participants felt less discomfort. PMID:29734360
NASA's James Webb Space Telescope Science Instruments Begin Final Super Cold Test at Goddard
2017-12-08
At NASA's James Webb Space Telescope's final destination in space, one million miles away from Earth, it will operate at incredibly cold temperatures of -387 degrees Fahrenheit, or 40 degrees Kelvin. This is 260 degrees Fahrenheit colder than any place on the Earth’s surface has ever been. So first, this final super cold test at Goddard will prepare the Integrated Science Instrument Module (ISIM), or the “heart” of the telescope, for space. Read more: go.nasa.gov/1KFPwJG Contamination Control Engineer Alan Abeel conducts final inspections and places contamination foils before the start of the test. Credit: NASA/Goddard/Chris Gunn NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Realizing universal Majorana fermionic quantum computation
NASA Astrophysics Data System (ADS)
Wu, Ya-Jie; He, Jing; Kou, Su-Peng
2014-08-01
Majorana fermionic quantum computation (MFQC) was proposed by S. B. Bravyi and A. Yu. Kitaev [Ann. Phys. (NY) 298, 210 (2002), 10.1006/aphy.2002.6254], who indicated that a (nontopological) fault-tolerant quantum computer built from Majorana fermions may be more efficient than that built from distinguishable two-state systems. However, until now scientists have not known how to realize a MFQC in a physical system. In this paper we propose a possible realization of MFQC. We find that the end of a line defect of a p-wave superconductor or superfluid in a honeycomb lattice traps a Majorana zero mode, which becomes the starting point of MFQC. Then we show how to manipulate Majorana fermions to perform universal MFQC, which possesses possibilities for high-level local controllability through individually addressing the quantum states of individual constituent elements by using timely cold-atom technology.
Drive cycle analysis of butanol/diesel blends in a light-duty vehicle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miers, S. A.; Carlson, R. W.; McConnell, S. S.
2008-10-01
The potential exists to displace a portion of the petroleum diesel demand with butanol and positively impact engine-out particulate matter. As a preliminary investigation, 20% and 40% by volume blends of butanol with ultra low sulfur diesel fuel were operated in a 1999 Mercedes Benz C220 turbo diesel vehicle (Euro III compliant). Cold and hot start urban as well as highway drive cycle tests were performed for the two blends of butanol and compared to diesel fuel. In addition, 35 MPH and 55 MPH steady-state tests were conducted under varying road loads for the two fuel blends. Exhaust gas emissions,more » fuel consumption, and intake and exhaust temperatures were acquired for each test condition. Filter smoke numbers were also acquired during the steady-state tests.« less
Singh, Karan; Samant, Manas Arun; Tom, Megha Treesa; Prasad, Nagaraj Guru
2016-01-01
Background In Drosophila melanogaster the fitness of males depends on a broad array of reproductive traits classified as pre- and post-copulatory traits. Exposure to cold stress, can reduce sperm number, male mating ability and courtship behavior. Therefore, it is expected that the adaptation to cold stress will involve changes in pre- and post-copulatory traits. Such evolution of reproductive traits in response to cold stress is not well studied. Methods We selected replicate populations of D. melanogaster for resistance to cold shock. Over 37–46 generations of selection, we investigated pre- and post-copulatory traits such as mating latency, copulation duration, mating frequency, male fertility, fitness (progeny production) and sperm competitive ability in male flies subjected to cold shock and those not subjected to cold shock. Results We found that post cold shock, the males from the selected populations had a significantly lower mating latency along with, higher mating frequency, fertility, sperm competitive ability and number of progeny relative to the control populations. Conclusion While most studies of experimental evolution of cold stress resistance have documented the evolution of survivorship in response to selection, our study clearly shows that adaptation to cold stress involves rapid changes in the pre- and post-copulatory traits. Additionally, improved performances under stressful conditions need not necessarily trade-off with performance under benign conditions. PMID:27093599
Repetitive cryotherapy attenuates the in vitro and in vivo mononuclear cell activation response.
Lindsay, Angus; Othman, Mohd Izani; Prebble, Hannah; Davies, Sian; Gieseg, Steven P
2016-07-01
What is the central question of this study? Acute and repetitive cryotherapy are routinely used to accelerate postexercise recovery, although the effect on resident immune cells and repetitive exposure has largely been unexplored and neglected. What is the main finding and its importance? Using blood-derived mononuclear cells and semi-professional mixed martial artists, we show that acute and repetitive cryotherapy reduces the in vitro and in vivo T-cell and monocyte activation response whilst remaining independent of the physical performance of elite athletes. We investigated the effect of repetitive cryotherapy on the in vitro (cold exposure) and in vivo (cold water immersion) activation of blood-derived mononuclear cells following high-intensity exercise. Single and repeated cold exposure (5°C) of a mixed cell culture (T cells and monocytes) was investigated using in vitro tissue culture experimentation for total neopterin production (neopterin plus 7,8-dihydroneopterin). Fourteen elite mixed martial art fighters were also randomly assigned to either a cold water immersion (15 min at 10°C) or passive recovery protocol, which they completed three times per week during a 6 week training camp. Urine was collected and analysed for neopterin and total neopterin three times per week, and perceived soreness, fatigue, physical performance (broad jump, push-ups and pull-ups) and training performance were also assessed. Single and repetitive cold exposure significantly (P < 0.001) reduced total neopterin production from the mixed cell culture, whereas cold water immersion significantly (P < 0.05) attenuated urinary neopterin and total neopterin during the training camp without having any effect on physical performance parameters. Soreness and fatigue showed little variation between the groups, whereas training session performance was significantly (P < 0.05) elevated in the cold water immersion group. The data suggest that acute and repetitive cryotherapy attenuates in vitro T-cell and monocyte activation. This may explain the disparity in in vivo neopterin and total neopterin between cold water immersion and passive recovery following repetitive exposure during a high-intensity physical impact sport that remains independent of physical performance. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.
Code of Federal Regulations, 2014 CFR
2014-07-01
... climate control system with the heat on and set to primarily defrost the front window. Turn air.... (i) Prior to the first acceleration, 20 seconds after the start of the UDDS, set the climate control... climate control system): (A) Temperature. Set controls to maximum heat. (B) Fan speed. Set the fan speed...
ERIC Educational Resources Information Center
Medhurst, Laura L.
2005-01-01
An experiment developed from the Advanced Integrated Environmental Laboratory illustrates the differences in automobile exhaust before and after the engine is warmed, using gas-phase Fourier transform infrared spectroscopy (FTIR). The apparatus consists of an Avatar 360 FTIR spectrometer from Nicolet fitted with a variable path length gas cell,…
NASA Astrophysics Data System (ADS)
Modak, Pranabananda; Patra, Sudipta; Mitra, Rahul; Chakrabarti, Debalay
2018-03-01
Effect of the initial as-cast structure on the microstructure-texture evolution during thermomechanical processing of 409L grade ferritic stainless steel was studied. Samples from the regions of cast slab having `columnar,' `equiaxed,' and a mixture of `columnar' and `equiaxed' grains were subjected to two different processing schedules: one with intermediate hot-band annealing before cold-rolling followed by final annealing, and another without any hot-band annealing. EBSD study reveals that large columnar crystals with cube orientation are very difficult to deform and recrystallize uniformly. Resultant variations in ferrite grain structure and retention of cube-textured band in cold-rolled and annealed sheet contribute to ridging behavior during stretch forming. Initial equiaxed grain structure is certainly beneficial to reduce or even eliminate ridging defect by producing uniform ferrite grain structure, free from any texture banding. Application of hot-band annealing treatment is also advantageous as it can maximize the evolution of beneficial gamma-fiber texture and eliminate the ridging defect in case of completely `equiaxed' starting structure. Such treatment reduces the severity of ridging even if the initial structure contains typically mixed `columnar-equiaxed' grains.
Oil strategies benefits over different driving cycles using numerical simulation
NASA Astrophysics Data System (ADS)
Sara, Hanna; Chalet, David; Cormerais, Mickaël; Hetet, Jean-François
2017-08-01
95 g/km is the allowed quantity of CO2 emission normalized to NEDC to be set in 2020. In addition, NEDC will be replaced by more severe driving cycles and will be united worldwide. To respond to those criteria, automotive industries are working on every possible field. Thermal management has been proved to be effective in reducing fuel consumption. Cold start is a primordial reason of overconsumption, as the engine highest efficiency is at its optimal temperature. At cold start, the engine's oil is at its lowest temperature and thus its higher viscosity level. A high viscosity oil generates more friction, which is one of the most important heat losses in the engine. In this paper, hot oil storage is studied. Numerical simulations on GT-suite model were done. The model consists of a 4-cylinder turbocharged Diesel engine using a storage volume of 1 liter of hot oil. Ambient temperature variation were taken into consideration as well as different driving cycles. Furthermore, different configurations of the thermal strategy (multifunction oil sump) were proposed and evaluated. Lubricant temperature and viscosity profiles are presented in the article as well as fuel consumption savings for different configurations, driving cycles and ambient temperatures.
NASA Astrophysics Data System (ADS)
Modak, Pranabananda; Patra, Sudipta; Mitra, Rahul; Chakrabarti, Debalay
2018-06-01
Effect of the initial as-cast structure on the microstructure-texture evolution during thermomechanical processing of 409L grade ferritic stainless steel was studied. Samples from the regions of cast slab having `columnar,' `equiaxed,' and a mixture of `columnar' and `equiaxed' grains were subjected to two different processing schedules: one with intermediate hot-band annealing before cold-rolling followed by final annealing, and another without any hot-band annealing. EBSD study reveals that large columnar crystals with cube orientation are very difficult to deform and recrystallize uniformly. Resultant variations in ferrite grain structure and retention of cube-textured band in cold-rolled and annealed sheet contribute to ridging behavior during stretch forming. Initial equiaxed grain structure is certainly beneficial to reduce or even eliminate ridging defect by producing uniform ferrite grain structure, free from any texture banding. Application of hot-band annealing treatment is also advantageous as it can maximize the evolution of beneficial gamma-fiber texture and eliminate the ridging defect in case of completely `equiaxed' starting structure. Such treatment reduces the severity of ridging even if the initial structure contains typically mixed `columnar-equiaxed' grains.
Rutting Performance of Cold-Applied Asphalt Repair Materials for Airfield Pavements
2017-06-23
susceptibility of hot mix asphalt (HMA) using the asphalt pavement analyzer (APA). Designation T340- 10. Washington, DC: American Association of State...ER D C/ G SL T R- 17 -1 0 Rutting Performance of Cold-Applied Asphalt Repair Materials for Airfield Pavements G eo te ch ni ca l a nd S...of Cold-Applied Asphalt Repair Materials for Airfield Pavements Ben C. Cox, John F. Rushing, and Web Floyd Geotechnical and Structures Laboratory
Influence of snow temperature on avalanche impact pressure
NASA Astrophysics Data System (ADS)
Sovilla, Betty; Koehler, Anselm; Steinkogler, Walter; Fischer, Jan-Thomas
2015-04-01
The properties of the snow entrained by an avalanche during its motion (density, temperature) significantly affect flow dynamics and can determine whether the flowing material forms granules or maintains its original fine-grained structure. In general, a cold and light snow cover typically fluidizes, while warmer and more cohesive snow may form a granular denser layer in a flowing avalanche. This structural difference has a fundamental influence not only in the mobility of the flow but also on the impact pressure of avalanches. Using measurements of impact pressure, velocity, density and snow temperature performed at the Swiss Vallée de la Sionne full-scale test site, we show that, impact pressure fundamentally changes with snow temperature. A transition threshold of about -2°C is determined, the same temperature at which snow granulation starts. On the one hand warm avalanches, characterized by temperatures larger than -2°C, move as a plug and exert impact pressures linearly proportional to the avalanche depth. For Froude numbers larger than 1, an additional square-velocity dependent contribution cannot be neglected. On the other hand cold avalanches, characterized by a temperature smaller than -2°C, move as dense sheared flows, or completely dilute powder clouds and exert impact pressures, which are mainly proportional to the square of the flow velocity. For these avalanches the impact pressures strongly depend on density variations within the flow. We suggest that the proposed temperature threshold can be used as a criterion to define the transition between the impact pressures exerted by warm and cold avalanches, thus offering a new way to elude the notorious difficulties in defining the differences between wet and dry flow, respectively.
Temporal prolongation of decreased skin blood flow causes cold limbs in Parkinson's disease.
Shindo, Kazumasa; Kobayashi, Fumikazu; Miwa, Michiaki; Nagasaka, Takamura; Takiyama, Yoshihisa; Shiozawa, Zenji
2013-03-01
To unravel the pathogenesis of cold limbs in Parkinson's disease, we evaluated cutaneous vasomotor neural function in 25 Parkinson's disease patients with or without cold limbs and 20 healthy controls. We measured resting skin sympathetic nerve activity, as well as reflex changes of skin blood flow and skin sympathetic nerve activity after electrical stimulation, with the parameters including skin sympathetic nerve activity frequency at rest, the amplitude of reflex bursts, the absolute decrease and percent reduction of blood flow, and the recovery time which was calculated as the interval from the start of blood flow reduction until the return to baseline cutaneous blood flow. The resting frequency of skin sympathetic nerve activity was significantly lower in patients with Parkinson's disease than in controls (p < 0.01). There were no significant differences between the patients and controls with respect to the amplitude of skin sympathetic nerve activity and the absolute decrease or percent reduction of blood flow volume. In the controls, the recovery time (9.4 ± 1.2), which was similar to Parkinson's disease patients without cold limbs (9.0 ± 0.7), while the recovery time ranged (15.7 ± 3.2) in Parkinson's disease patients with cold limbs. Recovery was significantly slower in these patients compared with the other groups (p < 0.05). It is possible that cold limbs might arise due to impaired circulation based on prolonged vasoconstriction by peripheral autonomic impairments, in addition to central autonomic dysfunction in Parkinson's disease.
Satellite microwave observations of a storm complex: A comparative analysis
NASA Technical Reports Server (NTRS)
Martin, D. W.
1985-01-01
The hypothesis that cold events correspond to a particular stage in a class of thunderstorms was tested. That class is a storms class which updrafts are: (1) strong, broad and moist, and (2) extend well above the freezing level. Condition (1) implies strong mesoscale forcing. Condition (2) implies a tall updraft or a relatively low freezing level. Such storms should have big, intense radar echoes and cold, fast-growing anvils. The thunderstorm events were analyzed by radar, rain gauge and GOES infrared observations. Radar was the starting point for detection and definition of the hypothesized thunderstorms. The radar signature is compared to the signature of the storm in rain gauge observations, satellite infrared images and satellite microwave images.
UFTI: the 0.8 - 2.5 μm fast track imager for the UK infrared telescope
NASA Astrophysics Data System (ADS)
Roche, Patrick F.; Lucas, Philip W.; Mackay, Craig D.; Ettedgui-Atad, Eli; Hastings, Peter R.; Bridger, Alan; Rees, Nicholas P.; Leggett, Sandy K.; Davis, Chris; Holmes, Alan R.; Handford, Tony
2003-03-01
In 1996, it was proposed to build a near-infrared imager for the 3.8-m UK Infrared Telescope in Hawaii, to exploit the 1024 pixel format detectors that were then becoming available. In order to achieve a fast delivery, the instrument was kept simple and existing designs were reused or modified where possible. UFTI was delivered within 2.5 years of the project start. The instrument is based around a 1k Rockwell Hawaii detector and a LSR Astrocam controller and uses the new Mauna Kea optimized J,H,K filter set along with I and Z broad-band filters and several narrow-band line filters. The instrument is cooled by a CTI cry-cooler, while the mechanisms are operated by cold, internal, Bergelahr stepping motors. On UKIRT it can be coupled to a Fabry-Perot etalon for tunable narrow-band imaging at K, or a waveplate for imaging polarimetry through 1-2.5 μm the cold analyzer is a Barium Borate Wollaston prism. UFTI was designed to take full advantage of the good image quality delivered by UKIRT on conclusion of the upgrades program, and has a fine scale of 0.09 arcsec/pixel. It is used within the UKIRT observatory environment and was the first instrument integrated into ORAC, the Observatory Reduction and Acquisition Control System. Results obtained during instrument characterization in the lab and over the last 3 years on UKIRT are presented, along with performance figures. UFTI has now been used on UKIRT for several hundred nights, and aspects of instrument performance are discussed.
Field Emission Cold Cathode Devices Based on Eutectic Systems
1981-07-01
8217RADC-TR-811-170 ’,Final Technical Report July 1981 FIELD EMISSION COLD CATHODE DEVICES BASED ON EUTECTIC SYSTEMS Fulmer Research Institute Ltd...and identify by block numrber) Field Emission Eutectic Systems Cold Cathode Rod Eutectics Electron Emitter Array Directionally Solidified Eutectics...Identify by block number) A survey has been made of the performance as field emission cold cathodes of selected refractory materials fabricated as
Cold Regions - Environmental Testing of Individual Soldier Clothing
2011-10-17
Individual Soldier Clothing 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS 5d. PROJECT NUMBER 5e. TASK...This Test Operations Procedure (TOP) provides testing guidelines for individual Soldier cold weather clothing and footwear in a cold regions...Soldier clothing , along with its safety, reliability, durability, and performance when exposed to a cold regions environment. 15. SUBJECT TERMS
IEA HPT ANNEX 41 – Cold climate heat pumps: US country report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groll, Eckhard A.; Baxter, Van D.
In 2012 the International Energy Agency (IEA) Heat Pump Programme (now the Heat Pump Technologies (HPT) program) established Annex 41 to investigate technology solutions to improve performance of heat pumps for cold climates. Four IEA HPT member countries are participating in the Annex – Austria, Canada, Japan, and the United States (U.S.). The principal focus of Annex 41 is on electrically driven air-source heat pumps (ASHP) since that system type has the lowest installation cost of all heat pump alternatives. They also have the most significant performance challenges given their inherent efficiency and capacity issues at cold outdoor temperatures. Availabilitymore » of ASHPs with improved low ambient performance would help bring about a much stronger heat pump market presence in cold areas, which today rely predominantly on fossil fuel furnace heating systems.« less
Study on Self-start up of Polymer Electrolyte Fuel Cell Stack at Subzero Temperature
NASA Astrophysics Data System (ADS)
Shirato, Hiroyasu; Hoshina, Hideo; Yamakoshi, Yukiyasu; Tomita, Kazuhiko; Oka, Yoshiaki
This paper aims to boot up polymer electrolyte fuel cells at subzero temperature without energy from outside and compass the conditions. Visualization tests of water drainage and voltage-current density characteristics provided the selection of a serpentine type as a channel of a fuel cell separator for cold region. The successful start-up of the cell at subzero temperature requires suitable current densities corresponding to the ambient temperature since the lower the temperature is, the lower the cell voltage soon after the start-up is. Suitable amount of exhausted energy is also necessary for the successful self start-up. Humidification using potassium acetate 30 mass% solution provides increased impedance of the cell and inhibits the water freezing owing to its dispersal to the electrode compared to no humidification. A stack laminated 25 sheets of the serpentine type separators enables stabilized power generation at normal temperature. The stack is also bootable with no energy from outside at 263K.
Anderson, G.B.; Jones, B.; McGinnis, S.A.; Sanderson, B.
2015-01-01
Previous studies examining future changes in heat/cold waves using climate model ensembles have been limited to grid cell-average quantities. Here, we make use of an urban parameterization in the Community Earth System Model (CESM) that represents the urban heat island effect, which can exacerbate extreme heat but may ameliorate extreme cold in urban relative to rural areas. Heat/cold wave characteristics are derived for U.S. regions from a bias-corrected CESM 30-member ensemble for climate outcomes driven by the RCP8.5 forcing scenario and a 15-member ensemble driven by RCP4.5. Significant differences are found between urban and grid cell-average heat/cold wave characteristics. Most notably, urban heat waves for 1981–2005 are more intense than grid cell-average by 2.1°C (southeast) to 4.6°C (southwest), while cold waves are less intense. We assess the avoided climate impacts of urban heat/cold waves in 2061–2080 when following the lower forcing scenario. Urban heat wave days per year increase from 6 in 1981–2005 to up to 92 (southeast) in RCP8.5. Following RCP4.5 reduces heat wave days by about 50%. Large avoided impacts are demonstrated for individual communities; e.g., the longest heat wave for Houston in RCP4.5 is 38 days while in RCP8.5 there is one heat wave per year that is longer than a month with some lasting the entire summer. Heat waves also start later in the season in RCP4.5 (earliest are in early May) than RCP8.5 (mid-April), compared to 1981–2005 (late May). In some communities, cold wave events decrease from 2 per year for 1981–2005 to one-in-five year events in RCP4.5 and one-in-ten year events in RCP8.5. PMID:29520121
McNulty, E.W.; Dwyer, F.J.; Ellersieck, Mark R.; Greer, E.I.; Ingersoll, C.G.; Rabeni, C.F.
1999-01-01
Standard methods for conducting toxicity tests imply that the condition of test organisms can be established using reference toxicity tests. However, only a limited number of studies have evaluated whether reference toxicity tests can actually be used to determine if organisms are in good condition at the start of a test. We evaluated the ability of reference toxicants to identify stress associated with starvation in laboratory populations of the amphipod Hyalella azteca using acute toxicity tests and four reference toxicants: KCl, CdCl2, sodium pentachlorophenate (NaPCP), and carbaryl. Stress associated with severe starvation was observed with exposure of amphipods to carbaryl or NaPCP but not with exposure to KCl or CdCl2 (i.e., lower LC50 with severe starvation). Although the LC50s for NaPCP and carbaryl were statistically different between starved and fed amphipods, this difference may not be biologically significant given the variability expected in acute lethality tests. Stress associated with sieving, heat shock, or cold shock of amphipods before the start of a test was not evident with exposure to carbaryl or KCl as reference toxicants. The chemicals evaluated in this study provided minimal information about the condition of the organisms used to start a toxicity test. Laboratories should periodically perform reference toxicity tests to assess the sensitivity of life stages or strains of test organisms. However, use of other test acceptability criteria required in standard methods such as minimum survival, growth, or reproduction of organisms in the control treatment at the end of a test, provides more useful information about the condition of organisms used to start a test compared to data generated from reference toxicity tests.
Influence of coating defects on the corrosion behavior of cold sprayed refractory metals
NASA Astrophysics Data System (ADS)
Kumar, S.; Rao, A. Arjuna
2017-02-01
The defects in the cold sprayed coatings are critical in the case of corrosion performances of the coatings in aggressive conditions. To understand the influence of coating defects on corrosion, immersion tests have been carried out in HF solution for the cold sprayed and heat treated Titanium, Tantalum and Niobium coatings. Long duration immersion tests reveal inhomogeneous weight losses of the samples prepared at different heat treatment conditions. The weight loss for different coatings has been well corroborated with the coating defects and microstructures. Chemical and micro structural analysis elucidates the reason behind the inhomogeneous performance of different type of cold sprayed coatings in corrosion medium. In the case of cold sprayed titanium, formation of stable oxide along the inter-splat boundary hinders the aggressive attack of the corrosion medium which is not so in other cases.
Pulse tube cryocooler for IR applications
NASA Astrophysics Data System (ADS)
Korf, H.; Ruhlich, I.; Mai, M.; Thummes, G.
2005-05-01
Pulse tube cryocoolers (PTC) can be regarded as the next step in the development of the Stirling cooler. The major advantage vs. the Stirling cooler is the omission of any moving part in the cold head, resulting in significantly increased MTTF. Further advantages are higher mechanical robustness and stability and the potential for cost reduction. AIM developed PTC's for several years in close cooperation with the University of Giessen. As a recent result at AIM, Coaxial PTC cold head are available within the outline dimension of typical IR Stirling cold head of 13mm diameter. The achieved performance data are comparable to the serial data of the Stirling cold head. This PTC cold head is designed to be operated in the orifice mode without a double inlet which is known to cause instabilities. Technical details and performance data represent the current technical status at AIM.
A novel methodology for quantifying the performance of constructed bridges in cold regions.
DOT National Transportation Integrated Search
2014-04-01
This report presents a two-part research program examining the performance of constructed bridges in a : cold region, represented by those in the State of North Dakota, and the behavior of concrete members : strengthened with carbon fiber reinforced ...
Effect of cold indoor environment on physical performance of older women living in the community.
Lindemann, Ulrich; Oksa, Juha; Skelton, Dawn A; Beyer, Nina; Klenk, Jochen; Zscheile, Julia; Becker, Clemens
2014-07-01
the effects of cold on older persons' body and mind are not well documented, but with an increased number of older people with decreasing physical performance, these possible effects need to be understood. to investigate the effect of cold indoor environment on physical performance of older women. cross-sectional experimental study with two test conditions. movement laboratory in a climate chamber. eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). participants were exposed to moderately cold (15°C) and warm/normal (25°C) temperature in a climate chamber in random order with an interval of 1 week. The assessment protocol included leg extensor power (Nottingham Power Rig), sit-to-stand performance velocity (linear encoder), gait speed, walk-ratio (i.e. step length/cadence on an instrumented walk way), maximal quadriceps and hand grip strength. physical performance was lower in 15°C room temperature compared with 25°C room temperature for leg extensor power (P < 0.0001), sit-to-stand performance velocity (P < 0.0001), gait speed (P < 0.0001), walk-ratio (P = 0.016) and maximal quadriceps strength (P = 0.015), but not for hand grip strength. in healthy older women a moderately cold indoor environment decreased important physical performance measures necessary for independent living. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Exploratory Investigation into the Durability of Beneficial Cold Worked Fastener Hole in Aluminum
NASA Technical Reports Server (NTRS)
Johnson, W. S.; Clark, David A.
1999-01-01
Cold working fastener holes in aluminum alloys is a widely used technique in the aerospace industry for improving the fatigue performance of structures. A compressive tangential stress introduced in the material during the cold working of the hole reduces the natural tendency of the material to crack at the holes under cyclic tensile loading. It is a lucrative technique for the aerospace industry in that it provides an increase in performance without any weight cost.
NASA Technical Reports Server (NTRS)
Werrett, Stephen; Seivold, Alfred L.
1990-01-01
A detailed nodal computer model was developed to thermally represent the hardware, and sensitivity studies were performed to evaluate design parameters and orbital environmental effects of an instrument cooling system for IR detectors. Thermal-vacuum testing showed excellent performance of the system and a correspondence with math model predictions to within 3 K. Results show cold stage temperature sensitivity to cold patch backload, outer stage external surface emittance degradation, and cold stage emittance degradation, respectively. The increase in backload on the cold patch over the mission lifetime is anticipated to be less than 3.0 watts, which translates to less than a 3-degree increase in detector temperatures.
DOT National Transportation Integrated Search
2014-04-01
This report presents a two-part research program examining the performance of constructed : bridges in a cold region, represented by those in the State of North Dakota, and the behavior of : concrete members strengthened with carbon fiber reinforced ...
Performance evaluation approach for the supercritical helium cold circulators of ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaghela, H.; Sarkar, B.; Bhattacharya, R.
2014-01-29
The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe coldmore » circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.« less
The performance of the upgraded Los Alamos Neutron Source
NASA Astrophysics Data System (ADS)
Ito, Takeyasu; LANL UCN Source Collaboration
2017-09-01
Los Alamos National Laboratory has been operating an ultracold (UCN) source based on a solid deuterium (SD2) UCN converter driven by spallation neutrons for over 10 years. It has recently been successfully upgraded, by replacing the cryostat that contains the cold neutron moderator, SD2 volume, and vertical UCN guide. The horizontal UCN guide that transports UCN out of the radiation shield was also replaced. The new design reflects lessons learned from the 10+ year long operation of the previous version of the UCN source and is optimized to maximize the cold neutron flux at the SD2 volume, featuring a close coupled cold neutron moderator, and maximize the transport of the UCN to experiments. During the commissioning of the upgraded UCN source, data were collected to measure its performance, including cold neutron spectra as a function of the cold moderator temperature, and the UCN density in a vessel outside the source. In this talk, after a brief overview of the design of the upgraded source, the results of the performance tests and comparison to prediction will be presented. This work was funded by LANL LDRD.
Characteristics of the local cutaneous sensory thermoneutral zone
Zhang, Hui; Arens, Edward A.
2017-01-01
Skin temperature detection thresholds have been used to measure human cold and warm sensitivity across the temperature continuum. They exhibit a sensory zone within which neither warm nor cold sensations prevail. This zone has been widely assumed to coincide with steady-state local skin temperatures between 32 and 34°C, but its underlying neurophysiology has been rarely investigated. In this study we employ two approaches to characterize the properties of sensory thermoneutrality, testing for each whether neutrality shifts along the temperature continuum depending on adaptation to a preceding thermal state. The focus is on local spots of skin on the palm. Ten participants (age: 30.3 ± 4.8 yr) underwent two experiments. Experiment 1 established the cold-to-warm inter-detection threshold range for the palm’s glabrous skin and its shift as a function of 3 starting skin temperatures (26, 31, or 36°C). For the same conditions, experiment 2 determined a thermally neutral zone centered around a thermally neutral point in which thermoreceptors’ activity is balanced. The zone was found to be narrow (~0.98 to ~1.33°C), moving with the starting skin temperature over the temperature span 27.5–34.9°C (Pearson r = 0.94; P < 0.001). It falls within the cold-to-warm inter-threshold range (~2.25 to ~2.47°C) but is only half as wide. These findings provide the first quantitative analysis of the local sensory thermoneutral zone in humans, indicating that it does not occur only within a specific range of steady-state skin temperatures (i.e., it shifts across the temperature continuum) and that it differs from the inter-detection threshold range both quantitatively and qualitatively. These findings provide insight into thermoreception neurophysiology. NEW & NOTEWORTHY Contrary to a widespread concept in human thermoreception, we show that local sensory thermoneutrality is achievable outside the 32–34°C skin temperature range. We propose that sensory adaption underlies a new mechanism of temperature integration. Also, we have developed from vision research a new quantitative test addressing the balance in activity of cutaneous cold and warm thermoreceptors. This could have important clinical (assessment of somatosensory abnormalities in neurological disease) and applied (design of personal comfort systems) implications. PMID:28148644
40 CFR 86.1432 - Vehicle preparation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... cold temperature compliance pathway, the temperature of the fuel prior to its delivery to the fuel tank... is the Cold CO Test Procedure, performed in accordance with subpart C of this part. (ii) Testing by...). (C) Cold CO Test Procedure, in accordance with subpart C of this part. (c) Soak—(1) Manufacturer's...
40 CFR 86.1432 - Vehicle preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... cold temperature compliance pathway, the temperature of the fuel prior to its delivery to the fuel tank... is the Cold CO Test Procedure, performed in accordance with subpart C of this part. (ii) Testing by...). (C) Cold CO Test Procedure, in accordance with subpart C of this part. (c) Soak—(1) Manufacturer's...
1992-07-01
or vehicle should be suspected of possible CO poisoning. 4. DO NOT APPLY OINTMENTS , SNOW OR ICE TO THE BURN , 3. Proper field sanitation is very AND DO...susceptible to cold injuries, and the use of indoor stoves may lead to burns or suffocation. Operational problems often arise in cold weather. Heavy...potential for body heat to escape. When the skin is exposed to cold, the brain signals the blood vessels in the skin to tighten, and blood flow to the skin
Finite element analysis of composite beam-to-column connection with cold-formed steel section
NASA Astrophysics Data System (ADS)
Firdaus, Muhammad; Saggaff, Anis; Tahir, Mahmood Md
2017-11-01
Cold-formed steel (CFS) sections are well known due to its lightweight and high structural performance which is very popular for building construction. Conventionally, they are used as purlins and side rails in the building envelopes of the industrial buildings. Recent research development on cold-formed steel has shown that the usage is expanded to the use in composite construction. This paper presents the modelling of the proposed composite connection of beam-to-column connection where cold-formed steel of lipped steel section is positioned back-to-back to perform as beam. Reinforcement bars is used to perform the composite action anchoring to the column and part of it is embedded into a slab. The results of the finite element and numerical analysis has showed good agreement. The results show that the proposed composite connection contributes to significant increase to the moment capacity.
Utilization of Screw Piles in High Seismicity Areas of Cold and Warm Permafrost
DOT National Transportation Integrated Search
2010-07-01
This work was performed in support of the AUTC project Utilization of Screw Piles in : High Seismicity Areas of Cold and Warm Permafrost under the direction of PI Dr. Kenan : Hazirbaba. Surface wave testing was performed at 30 sites in the City...
Test Operations Procedure (TOP) 2-2-650 Engine Cold-Starting and Warm-Up Tests
2008-02-12
REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 ...currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1 . REPORT DATE (DD-MM-YYYY) 12-02-2008 2. REPORT...Page Paragraph 1 . SCOPE................................................................................ 2 2. FACILITIES AND INSTRUMENTATION
Apparatus for photocatalytic destruction of internal combustion engine emissions during cold start
Janata, Jiri; McVay, Gary L.; Peden, Charles H.; Exarhos, Gregory J.
1998-01-01
A method and apparatus for the destruction of emissions from an internal combustion engine wherein a substrate coated with TiO.sub.2 is exposed to a light source in the exhaust system of an internal combustion engine thereby catalyzing oxidation/reduction reactions between gaseous hydrocarbons, carbon monoxide, nitrogen oxides and oxygen in the exhaust of the internal combustion engine.
Wire and Cable Cold Bending Test
NASA Technical Reports Server (NTRS)
Colozza, Anthony
2010-01-01
One of the factors in assessing the applicability of wire or cable on the lunar surface is its flexibility under extreme cold conditions. Existing wire specifications did not address their mechanical behavior under cold, cryogenic temperature conditions. Therefore tests were performed to provide this information. To assess this characteristic 35 different insulated wire and cable pieces were cold soaked in liquid nitrogen. The segments were then subjected to bending and the force was recorded. Any failure of the insulation or jacketing was also documented for each sample tested. The bending force tests were performed at room temperature to provide a comparison to the change in force needed to bend the samples due to the low temperature conditions. The results from the bending tests were plotted and showed how various types of insulated wire and cable responded to bending under cold conditions. These results were then used to estimate the torque needed to unroll the wire under these low temperature conditions.
Extended Deterrence, Nuclear Proliferation, and START III
DOE Office of Scientific and Technical Information (OSTI.GOV)
Speed, R.D.
2000-06-20
Early in the Cold War, the United States adopted a policy of ''extended nuclear deterrence'' to protect its allies by threatening a nuclear strike against any state that attacks these allies. This threat can (in principle) be used to try to deter an enemy attack using conventional weapons or one using nuclear, chemical, or biological weapons. The credibility of a nuclear threat has long been subject to debate and is dependent on many complex geopolitical factors, not the least of which is the military capabilities of the opposing sides. The ending of the Cold War has led to a significantmore » decrease in the number of strategic nuclear weapons deployed by the United States and Russia. START II, which was recently ratified by the Russian Duma, will (if implemented) reduce the number deployed strategic nuclear weapons on each side to 3500, compared to a level of over 11,000 at the end of the Cold War in 1991. The tentative limit established by Presidents Clinton and Yeltsin for START III would reduce the strategic force level to 2000-2500. However, the Russians (along with a number of arms control advocates) now argue that the level should be reduced even further--to 1500 warheads or less. The conventional view is that ''deep cuts'' in nuclear weapons are necessary to discourage nuclear proliferation. Thus, as part of the bargain to get the non-nuclear states to agree to the renewal of the Nuclear Non-Proliferation Treaty, the United States pledged to work towards greater reductions in strategic forces. Without movement in the direction of deep cuts, it is thought by many analysts that some countries may decide to build their own nuclear weapons. Indeed, this was part of the rationale India used to justify its own nuclear weapons program. However, there is also some concern that deep cuts (to 1500 or lower) in the U.S. strategic nuclear arsenal could have the opposite effect. The fear is that such cuts might undermine extended deterrence and cause a crisis in confidence among U.S. allies to such an extent that they could seek nuclear weapons of their own to protect themselves.« less
A pilot study exploring the effects of reflexology on cold intolerance.
Zhang, Wenping; Takahashi, Shougo; Miki, Takashi; Fujieda, Hisayo; Ishida, Torao
2010-03-01
Cold intolerance is an inability to tolerate cold temperatures and is accompanied by symptoms including headache, shoulder discomfort, dizziness and palpitations. The current study was performed to examine whether reflexology therapy affected cold intolerance in human subjects and whether the treatment was systemically effective. Ten female volunteer examinees with subjective feelings of cold were examined. After a 5-minute foot bath, 10 minutes of reflexology therapy was performed on their left foot. Skin temperature and blood flow were estimated before and after treatment, together with an interview concerning their feelings of cold and daily habits. In addition, how the recovery rate was affected by the application of a chilled-water load was also estimated. Along with significant increases in skin temperature and blood flow compared with pre-treatment at the bilateral points of KI-1, LR-3, and BL-60, a faster recovery after the application of the chilled-water load was also seen in the lower limbs on both sides. From these results, we conclude that reflexology has systemic effects and is an alternative method for treating cold intolerance. Copyright (c) 2010 Korean Pharmacopuncture Institute. Published by .. All rights reserved.
Human thermal responses during leg-only exercise in cold water.
Golden, F S; Tipton, M J
1987-10-01
1. Exercise during immersion in cold water has been reported by several authors to accelerate the rate of fall of core temperature when compared with rates seen during static immersion. The nature of the exercise performed, however, has always been whole-body in nature. 2. In the present investigation fifteen subjects performed leg exercise throughout a 40 min head-out immersion in water at 15 degrees C. The responses obtained were compared with those seen when the subjects performed an identical static immersion. 3. Aural and rectal temperatures were found to fall by greater amounts during static immersion. 4. It is concluded that 'the type of exercise performed' should be included in the list of factors which affect core temperature during cold water immersion.
NASA Astrophysics Data System (ADS)
Jayaram, S.; Daeid, N. Nic; Kerr, W. J.; Kemp, H. F.; Meier-Augenstein, W.
2012-04-01
This work exposes the variation in light element stable isotopic abundance values of 13C, 2H and 15N) derived from the analysis of methylamphetamine synthesized via 2 different synthetic routes popular with clandestine laboraties, the Hypophosphorous and the Moscow route. We repeatedly prepared the final product using known clandestine synthetic methods where the precursors, catalysts and reducing agents have themselves been derived from house hold products and commonly available cold medications. Methylamphetamine was prepared from both lab grade pseudoephedrine and pseudoephedrine extracted (using three different solvent systems) from Sudafed®, an over-the-counter cold medication widely available in the United Kingdom. Six repetitive batches of the final product were produced in each case to provide within and between batch variations thus yielding a total of 48 samples (24 for each route). We have demonstrated that stable isotope analysis by Isotope Ratio Mass Spectrometry (IRMS) is potentially useful in the comparison and discrimination of batches of methylamphetamine produced for each route and for each precursor depending on the solvent used for extracting the pseudoephedrine starting material. To our knowledge this is the first time multivariate stable isotope analysis has been applied to methylamphetamine samples synthesized from pseudoephedrine extracted from over-the-counter cold medications.
Evaluation of Losses Of Cold Energy of Cryogen Products in The Transport Systems
NASA Astrophysics Data System (ADS)
Uglanov, Dmitry; Sarmin, Dmitry; Tsapkova, Alexandra; Burdina, Yana
2017-12-01
At present, there are problems of energy saving in various areas of human life and in power complexes of industrial plants. One possible solution to the problem of increasing energy efficiency is the use of liquefied natural gas and its cold energy. Pipelines for fuel or gas supply in cryogen supply systems have different length depending on the mutual position of storage and cryogen consumption devices relatively to a start construction. Cryogen supply and transport systems include a lot of fittings of different assortment. Reservoirs can be installed on different elevation points. To reduce heat inleak and decrease cold energy of cryogen product different kinds of thermal insulation are used. Cryogen pipelines provide required operation conditions of storage and gasifying systems. The aim of the thermal calculation of cryogen transport and supply systems is to define the value of cryogen heat. In this paper it is shown values of cryogen temperature rise due to heat inleaks at cryogen’s transfer along transport systems for ethane, methane, oxygen and nitrogen were calculated. Heat inleaks also due to hydraulic losses were calculated. Specific losses of cold energy of cryogen product for laminar and turbulent flow were calculated. Correspondences of temperature rise, critical pipeline’s length and Reynolds number were defined for nitrogen, argon, methane and oxygen.
Spacecraft attitude impacts on COLD-SAT non-vacuum jacketed LH2 supply tank thermal performance
NASA Technical Reports Server (NTRS)
Arif, Hugh
1990-01-01
The Cryogenic On-Orbit Liquid Depot - Storage, Acquisition and Transfer (COLD-SAT) spacecraft will be launched into low earth orbit to perform fluid management experiments on the behavior of subcritical liquid hydrogen (LH2). For determining the optimum on-orbit attitude for the COLD-SAT satellite, a comparative analytical study was performed to determine the thermal impacts of spacecraft attitude on the performance of the COLD-SAT non-vacuum jacketed LH2 supply tank. Tank thermal performance was quantitied by total conductive and radiative heat leakage into the pressure vessel due to the absorbed solar, earth albedo and infra-red on-orbit fluxes, and also by the uniformity of the variation of this leakage on the vessel surface area. Geometric and thermal analysis math models were developed for the spacecraft and the tank as part of this analysis, based on their individual thermal/structural designs. Two quasi-inertial spacecraft attitudes were investigated and their effects on the tank performance compared. The results are one of the criteria by which the spacecraft orientation in orbit was selected for the in-house NASA Lewis Research Center design.
Spacecraft attitude impacts on COLD-SAT non-vacuum jacketed LH2 supply tank thermal performance
NASA Technical Reports Server (NTRS)
Arif, Hugh
1990-01-01
The Cryogenic On-Orbit Liquid Depot - Storage, Acquisition and Transfer (COLD-SAT) spacecraft will be launched into low earth orbit to perform fluid management experiments on the behavior of subcritical liquid hydrogen (LH2). For determining the optimum on-orbit attitude for the COLD-SAT satellite, a comparative analytical study was performed to determine the thermal impacts of spacecraft attitude on the performance of the COLD-SAT non-vacuum jacketed LH2 supply tank. Tank thermal performance was quantified by total conductive and radiative heat leakage into the pressure vessel due to the absorbed solar, earth albedo and infra-red on-orbit fluxes, and also by the uniformity of the variation of this leakage on the vessel surface area. Geometric and thermal analysis math models were developed for the spacecraft and the tank as part of this analysis, based on their individual thermal/structural designs. Two quasi-inertial spacecraft attitudes were investigated and their effects on the tank performance compared. The results are one of the criteria by which the spacecraft orientation in orbit was selected for the in-house NASA Lewis Research Center design.
The crabs that live where hot and cold collide.
Thurber, Andrew R
2015-07-01
The distribution of Kiwa tyleri with the large male individual in the high-temperature flow (right hand side - fluid flow indicated by shimmering water) and the mixed sex assemblage (left). Note the heavy coat of epibiotic bacteria (grey colouring) on the individual in the hottest section of the vent, as expected from being closest to the sulphide needed to sustain the epibiotic bacteria that this species harvests for its food. Image courtesy of Dr. L. Marsh (Credit: NERC ChEsSo Consortium). In Focus: Marsh, L., Copley, J.T., Tyler, P.A. & Thatje, S. (2015) In hot and cold water: differential life-history traits are key to success in contrasting thermal deep-sea environments. Journal of Animal Ecology, 84, 898-913. Southern Ocean hydrothermal vents juxtapose two extremes - intense food-poor cold and scalding food-rich oases. At these vents, Marsh et al. (2015) found a community of Kiwa (Yeti) crabs that separated themselves along this gradient with the largest males sitting in hot, food-rich waters, while smaller males and females co-occur in an intermediate zone of warmth. However, as their eggs start to develop, females embark away from the vent to the food-poor yet stable cold of the Southern Ocean. This species has found an intriguing way to balance foraging risk and population persistence at the interface of hot and cold. © 2015 The Author. Journal of Animal Ecology © 2015 British Ecological Society.
Black Hole Accretion and Feedback Driven by Thermal Instability
NASA Astrophysics Data System (ADS)
Gaspari, M.; Ruszkowski, M.; Oh, S. P.; Churazov, E.; Brighenti, F.; Ettori, S.; Sharma, P.; Temi, P.
2013-03-01
Multiwavelength data indicate that the cores of several galaxy clusters are moderately cooling, though not catastrophically, showing signs of filamentary extended multiphase gas. Through 3D AMR hydrodynamic simulations, we study the impact of thermal instability in the evolution of the intracluster medium. Common moderate turbulence of just over 100 km/s leads to the growth of nonlinear thermal instability within the central few tens kpc. In the presence of a global counterbalancing heating, the condensation of extended filamentary cold gas is violent, occurring when the cooling time falls below 10 times the free-fall time. The frequent stochastic collisions, fragmentations and shearing motions between the cold clouds, filaments and the central torus, efficiently reduce angular momentum. Tracking the accreting gas with a dynamical range of 10 million, we find that the accretion rate is boosted up to 100 times with respect to the Bondi rate. In a commonly turbulent and quasi-stable atmosphere, the mode of black accretion is cold and chaotic, substantially different from the classic idealized scenario. Only in the transonic regime, turbulent dissipation starts to inhibit thermal instability. On sub-parsec scales the cold phase is channeled via a funnel, triggering the black hole feedback likely linked to mechanical jets/outflows. As shown by long-term self-regulated simulations, the interplay of chaotic cold accretion and AGN feedback is crucial in order to avoid the cooling catastrophe and to reproduce the key thermodynamical features of observed clusters.
Hu, Zhengrong; Fan, Jibiao; Chen, Ke; Amombo, Erick; Chen, Liang; Fu, Jinmin
2016-04-01
The phytohormone ethylene has been reported to mediate plant response to cold stress. However, it is still debated whether the effect of ethylene on plant response to cold stress is negative or positive. The objective of the present study was to explore the role of ethylene in the cold resistance of Bermuda grass (Cynodon dactylon (L).Pers.). Under control (warm) condition, there was no obvious effect of the ethylene precursor 1-aminocyclopropane-1-carboxylic acid (ACC) or the antagonist Ag(+) of ethylene signaling on electrolyte leakage (EL) and malondialdehyde (MDA) content. Under cold stress conditions, ACC-treated plant leaves had a greater level of EL and MDA than the untreated leaves. However, the EL and MDA values were lower in the Ag(+) regime versus the untreated. In addition, after 3 days of cold treatment, ACC remarkably reduced the content of soluble protein and also altered antioxidant enzyme activity. Under control (warm) condition, there was no significant effect of ACC on the performance of photosystem II (PS II) as monitored by chlorophyll α fluorescence transients. However, under cold stress, ACC inhibited the performance of PS II. Under cold condition, ACC remarkably reduced the performance index for energy conservation from excitation to the reduction of intersystem electron acceptors (PI(ABS)), the maximum quantum yield of primary photochemistry (φP0), the quantum yield of electron transport flux from Q(A) to Q(B) (φE0), and the efficiency/probability of electron transport (ΨE0). Simultaneously, ACC increased the values of specific energy fluxes for absorption (ABS/RC) and dissipation (DI0/RC) after 3 days of cold treatment. Additionally, under cold condition, exogenous ACC altered the expressions of several related genes implicated in the induction of cold tolerance (LEA, SOD, POD-1 and CBF1, EIN3-1, and EIN3-2). The present study thus suggests that ethylene affects the cold tolerance of Bermuda grass by impacting the antioxidant system, photosystem II, as well as the CBF transcriptional regulatory cascade.
Attitude Sensor and Gyro Calibration for Messenger
NASA Technical Reports Server (NTRS)
O'Shaughnessy, Daniel; Pittelkau, Mark E.
2007-01-01
The Redundant Inertial Measurement Unit Attitude Determination/Calibration (RADICAL(TM)) filter was used to estimate star tracker and gyro calibration parameters using MESSENGER telemetry data from three calibration events. We present an overview of the MESSENGER attitude sensors and their configuration is given, the calibration maneuvers are described, the results are compared with previous calibrations, and variations and trends in the estimated calibration parameters are examined. The warm restart and covariance bump features of the RADICAL(TM) filter were used to estimate calibration parameters from two disjoint telemetry streams. Results show that the calibration parameters converge faster with much less transient variation during convergence than when the filter is cold-started at the start of each telemetry stream.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parkhomchuk, V.
1997-09-01
High energy electron cooling requires a very cold electron beam. The questions of using electron cooling with and without a magnetic field are presented for discussion at this workshop. The electron cooling method was suggested by G. Budker in the middle sixties. The original idea of the electron cooling was published in 1966. The design activities for the NAP-M project was started in November 1971 and the first run using a proton beam occurred in September 1973. The first experiment with both electron and proton beams was started in May 1974. In this experiment good result was achieved very closemore » to theoretical prediction for a usual two component plasma heat exchange.« less
Thermodynamic Study on the Effects of Minor Constituents on Cold Weather Performance of Biodiesel
USDA-ARS?s Scientific Manuscript database
Biodiesel is an alternative diesel fuel made from vegetable oils, animal fats and other lipid feedstocks. Fuel properties and performance of biodiesel during cold weather are influenced by factors related to its feedstock, namely fatty acid composition and trace concentrations of monoacylglycerols,...
Performance of a Battery Electric Vehicle in the Cold Climate and Hilly Terrain of Vermont
DOT National Transportation Integrated Search
2008-12-23
The goal of this research project was to determine the performance of a battery electric vehicle (BEV) in the cold climate and hilly terrain of Vermont. For this study, a 2005 Toyota Echo was converted from an internal combustion engine (ICE) vehicle...
Durham, W.B.; McKinnon, W.B.; Stern, L.A.
2005-01-01
Hydrostatic compaction of granulated water ice was measured in laboratory experiments at temperatures 77 K to 120 K. We performed step-wise hydrostatic pressurization tests on 5 samples to maximum pressures P of 150 MPa, using relatively tight (0.18-0.25 mm) and broad (0.25-2.0 mm) starting grain-size distributions. Compaction change of volume is highly nonlinear in P, typical for brittle, granular materials. No time-dependent creep occurred on the lab time scale. Significant residual porosity (???0.10) remains even at highest P. Examination by scanning electron microscopy (SEM) reveals a random configuration of fractures and broad distribution of grain sizes, again consistent with brittle behavior. Residual porosity appears as smaller, well-supported micropores between ice fragments. Over the interior pressures found in smaller midsize icy satellites and Kuiper Belt objects (KBOs), substantial porosity can be sustained over solar system history in the absence of significant heating and resultant sintering. Copyright 2005 by the American Geophysical Union.
Verspohl, Alexandra; Solieri, Lisa; Giudici, Paolo
2017-03-01
The selection and genetic improvement of wine yeast is an ongoing process, since yeast strains should match new technologies in winemaking to satisfy evolving consumer preferences. A large genetic background is the necessary starting point for any genetic improvement programme. For this reason, we collected and characterized a large number of strains belonging to Saccharomyces uvarum. In particular, 70 strains were isolated from cold-stored must samples: they were identified and compared to S. uvarum strains originating from different collections, regarding fermentation profile, spore viability and stress response. The results demonstrate a large biodiversity among the new isolates, with particular emphasis to fermentation performances, genotypes and high spore viability, making the isolates suitable for further genetic improvement programmes. Furthermore, few of them are competitive with Saccharomyces cerevisiae and per se, suitable for wine fermentation, due to their resistance to stress, short lag phase and fermentation by-products.
Game Theory Based Trust Model for Cloud Environment
Gokulnath, K.; Uthariaraj, Rhymend
2015-01-01
The aim of this work is to propose a method to establish trust at bootload level in cloud computing environment. This work proposes a game theoretic based approach for achieving trust at bootload level of both resources and users perception. Nash equilibrium (NE) enhances the trust evaluation of the first-time users and providers. It also restricts the service providers and the users to violate service level agreement (SLA). Significantly, the problem of cold start and whitewashing issues are addressed by the proposed method. In addition appropriate mapping of cloud user's application to cloud service provider for segregating trust level is achieved as a part of mapping. Thus, time complexity and space complexity are handled efficiently. Experiments were carried out to compare and contrast the performance of the conventional methods and the proposed method. Several metrics like execution time, accuracy, error identification, and undecidability of the resources were considered. PMID:26380365
The Effect of Foaming and Silica Dissolution on Melter Feed Rheology during Conversion to Glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marcial, Jose; Chun, Jaehun; Hrma, Pavel R.
As the nuclear waste glass melter feed is converted to molten glass, the feed eventually becomes a continuous glass-forming melt in which dissolving refractory constituents are suspended together with numerous gas bubbles. Knowledge of mechanical properties of the melter feed is crucial for understanding the feed-to-glass conversion as it occurs in the cold cap. We measured the viscosity during heating of the feed and correlated it with the independently determined volume fractions of dissolving quartz particles and the gas phase. The measurement was performed with a rotating spindle rheometer on the melter feed heated at 5 K/min starting at severalmore » different temperatures. The effect of quartz particles, gas bubbles, and compositional inhomogeneity on the glass-forming melt viscosity was determined by fitting a linear relationship between log viscosity and volume fractions of suspended phases to data.« less
NASA Astrophysics Data System (ADS)
Čiuldienė, D.; Aleinikovienė, J.; Muraškienė, M.; Marozas, V.; Armolaitis, K.
2017-01-01
This study was carried out in alien warmth-tolerant forest plantations of red oak ( Quercus rubra), common beech ( Fagus sylvatica) and European larch ( Larix decidua). We compared the changes in foliar litterfall mass and biochemical composition after five months of cold period. The mean mass of fresh foliar litterfall collected in late autumn was 30% higher in red oak compared to the larch and beech plantations. After the cold period, the reduction of foliar litterfall mass did not exceed 10% in any of the studied plantations. The fresh foliar litterfall of red oak was the richest in cellular fibre and easily decomposable glucose and nutrients such as P and Mg, larch was distinguished by the highest lignin, N, K and Ca concentrations, while beech fresh foliar litterfall was the poorest in the aforementioned nutrients. After the cold period, the changes in the biochemical composition of foliar litterfall revealed different patterns. In the spring, the beech and red oak foliar litterfall was the richest in N, P and Ca, meanwhile the larch foliar litterfall still had the highest concentration of lignin but, in contrast to the autumn, was the poorest in nutrients. After the cold period Lignin: N, C: N and C: P ratios reached critical values indicating that the foliar litterfall of beech and red oak had started to decompose. The highest lignin concentration and the highest and most stable Lignin: N, C: N, C: P and N: P ratios after the cold period indicated that the slowest foliar litterfall decomposition took place in the larch plantation.
Virkkunen, Ilkka; Yli-Hankala, Arvi; Silfvast, Tom
2004-09-01
The cooling and haemodynamic effects of prehospital infusion of ice-cold Ringer's solution were studied in 13 adult patients after successful resuscitation from non-traumatic cardiac arrest. After haemodynamics stabilisation, 30 ml/kg of Ringer's solution was infused at a rate of 100ml/min into the antecubital vein. Arterial blood pressure and blood gases, pulse rate, end-tidal CO(2) and oesophageal temperature were monitored closely. The mean core temperature decreased from 35.8 +/- 0.9 degrees C at the start of infusion to 34.0 +/- 1.2 degrees C on arrival at hospital (P < 0.0001). No serious adverse haemodynamic effects occurred. It is concluded that the induction of therapeutic hypothermia using this technique in the prehospital setting is feasible.
Experimentally Identify the Effective Plume Chimney over a Natural Draft Chimney Model
NASA Astrophysics Data System (ADS)
Rahman, M. M.; Chu, C. M.; Tahir, A. M.; Ismail, M. A. bin; Misran, M. S. bin; Ling, L. S.
2017-07-01
The demands of energy are in increasing order due to rapid industrialization and urbanization. The researchers and scientists are working hard to improve the performance of the industry so that the energy consumption can be reduced significantly. Industries like power plant, timber processing plant, oil refinery, etc. performance mainly depend on the cooling tower chimney’s performance, either natural draft or forced draft. Chimney is used to create sufficient draft, so that air can flow through it. Cold inflow or flow reversal at chimney exit is one of the main identified problems that may alter the overall plant performance. The presence Effective Plume Chimney (EPC) is an indication of cold inflow free operation of natural draft chimney. Different mathematical model equations are used to estimate the EPC height over the heat exchanger or hot surface. In this paper, it is aim to identify the EPC experimentally. In order to do that, horizontal temperature profiling is done at the exit of the chimneys of face area 0.56m2, 1.00m2 and 2.25m2. A wire mesh screen is installed at chimneys exit to ensure cold inflow chimney operation. It is found that EPC exists in all modified chimney models and the heights of EPC varied from 1 cm to 9 cm. The mathematical models indicate that the estimated heights of EPC varied from 1 cm to 2.3 cm. Smoke test is also conducted to ensure the existence of EPC and cold inflow free option of chimney. Smoke test results confirmed the presence of EPC and cold inflow free operation of chimney. The performance of the cold inflow free chimney is increased by 50% to 90% than normal chimney.
USDA-ARS?s Scientific Manuscript database
In the present study we used 2D-DIGE technique to document the Rhododendron proteome during the seasonal development of cold hardiness. We selected two genotypes with different cold hardiness levels. This enabled us to perform comparative analysis of their proteome profiles and screen differentially...
USDA-ARS?s Scientific Manuscript database
Background: Low environmental temperatures are among the most challenging stressors in poultry industries. Although landmark studies using acute severe cold exposure have been conducted, still the molecular mechanisms underlying cold-stress responses in birds are not completely defined. In the pre...
USDA-ARS?s Scientific Manuscript database
The physiological response of the preruminant calf to sustained exposure to cold has not been studied extensively. Effects of cold on growth performance and health of preruminant calves as well as functional measures of energy metabolism, fat-soluble vitamin, and immune responsiveness were evaluate...
Chen, Chengjie; Zhang, Yafeng; Xu, Zhiqiang; Luan, Aiping; Mao, Qi; Feng, Junting; Xie, Tao; Gong, Xue; Wang, Xiaoshuang; Chen, Hao; He, Yehua
2016-01-01
The pineapple (Ananas comosus) is cold sensitive. Most cultivars are injured during winter periods, especially in sub-tropical regions. There is a lack of molecular information on the pineapple’s response to cold stress. In this study, high-throughput transcriptome sequencing and gene expression analysis were performed on plantlets of a cold-tolerant genotype of the pineapple cultivar ‘Shenwan’ before and after cold treatment. A total of 1,186 candidate cold responsive genes were identified, and their credibility was confirmed by RT-qPCR. Gene set functional enrichment analysis indicated that genes related to cell wall properties, stomatal closure and ABA and ROS signal transduction play important roles in pineapple cold tolerance. In addition, a protein association network of CORs (cold responsive genes) was predicted, which could serve as an entry point to dissect the complex cold response network. Our study found a series of candidate genes and their association network, which will be helpful to cold stress response studies and pineapple breeding for cold tolerance. PMID:27656892
NASA Astrophysics Data System (ADS)
Mazaheri, Y.; Kermanpur, A.; Najafizadeh, A.
2015-07-01
A dual phase (DP) steel was produced by a new process utilizing an uncommon cold-rolling and subsequent intercritical annealing of a martensite-ferrite duplex starting structure. Ultrafine grained DP steels with an average grain size of about 2 μm and chain-networked martensite islands were achieved by short intercritical annealing of the 80 pct cold-rolled duplex microstructure. The strength of the low carbon steel with the new DP microstructure was reached about 1300 MPa (140 pct higher than that of the as-received state, e.g., 540 MPa), without loss of ductility. Tensile testing revealed good strength-elongation balance for the new DP steels (UTS × UE ≈ 11,000 to 15,000 MPa pct) in comparison with the previous works and commercially used high strength DP steels. Two strain hardening stages with comparable exponents were observed in the Holloman analysis of all DP steels. The variations of hardness, strength, elongation, and strain hardening behavior of the specimens with thermomechanical parameters were correlated to microstructural features.
Influence of driving cycles on unit emissions from passenger cars
NASA Astrophysics Data System (ADS)
Joumard, R.; André, M.; Vidon, R.; Tassel, P.; Pruvost, C.
Small samples of petrol engine or diesel cars, equipped with or without catalysts, were tested over 36 driving cycles divided into four categories - standard cycles and three sets of cycles more representative of real-world driving conditions. The tests addressed standard gaseous pollutants and fuel consumption and also less frequently measured pollutant such as CH 4. In the first part of this paper we examine cold emissions in order to assess the duration of the cold start impact and the representativity of the cold ECE15 cycle. Then unit emissions are compared over the four driving cycle families. As compared to representative cycles, the standardised cycles underestimate hot emissions by almost 50% for petrol engine cars and 30% for diesel vehicles. Conversely, the results obtained for the three representative cycle families are in relatively close agreement with each other - within approximately 10%. However, the cinematic properties of the three families differ. Finally, we demonstrate that weighting all emission data equally, not taking into account the weight of each cycle in overall traffic, introduces significant biases, particularly when plotting emission vs. average speed curves.
Analysis of responses of cold pressor tests on pilots and executives
NASA Technical Reports Server (NTRS)
Swaroop, R.
1977-01-01
Statistical analyses were performed to study the relationship between cold pressor test responses and certain medical attributes of a group of 81 pilots and a group of 466 executives. The important results of this study were as follows: There was a significant relationship between a subject's cold pressor test response and his profession (that is, pilot or executive). The executives' diastolic cold pressor test responses were significantly related to their medical conditions, and their families' medical conditions. Significant relationships were observed between executives' diastolic and systolic cold pressor test responses and their history of tranquilizer and cardiac drug use.
ATLAS LTCS Vertically Challenged System Lessons Learned
NASA Technical Reports Server (NTRS)
Patel, Deepak; Garrison, Matt; Ku, Jentung
2014-01-01
Re-planning of LTCS TVAC testing and supporting RTA (Receiver Telescope Assembly) Test Plan and Procedure document preparation. The Laser Thermal Control System (LTCS) is designed to maintain the lasers onboard Advanced Topographic Laser Altimeter System (ATLAS) at their operational temperatures. In order to verify the functionality of the LTCS, a thermal balance test of the thermal hardware was performed. During the first cold start of the LTCS, the Loop Heat Pipe (LHP) was unable to control the laser mass simulators temperature. The control heaters were fully on and the loop temperature remained well below the desired setpoint. Thermal analysis of the loop did not show these results. This unpredicted behavior of the LTCS was brought up to a panel of LHP experts. Based on the testing and a review of all the data, there were multiple diagnostic performed in order to narrow down the cause. The prevailing theory is that gravity is causing oscillating flow within the loop, which artificially increased the control power needs. This resulted in a replan of the LTCS test flow and the addition of a GSE heater to allow vertical operation.
Santin, Joseph M; Hartzler, Lynn K
2015-06-15
Locus coeruleus neurons of anuran amphibians contribute to breathing control and have spontaneous firing frequencies that, paradoxically, increase with cooling. We previously showed that cooling inhibits a depolarizing membrane current, the hyperpolarization-activated current (I h) in locus coeruleus neurons from bullfrogs, Lithobates catesbeianus (Santin JM, Watters KC, Putnam RW, Hartzler LK. Am J Physiol Regul Integr Comp Physiol 305: R1451-R1464, 2013). This suggests an unlikely role for I h in generating cold activation, but led us to hypothesize that inhibition of I h by cooling functions as a physiological brake to limit the cold-activated response. Using whole cell electrophysiology in brain slices, we employed 2 mM Cs(+) (an I h antagonist) to isolate the role of I h in spontaneous firing and cold activation in neurons recorded with either control or I h agonist (cyclic AMP)-containing artificial intracellular fluid. I h did not contribute to the membrane potential (V m) and spontaneous firing at 20°C. Although voltage-clamp analysis confirmed that cooling inhibits I h, its lack of involvement in setting baseline firing and V m precluded its ability to regulate cold activation as hypothesized. In contrast, neurons dialyzed with cAMP exhibited greater baseline firing frequencies at 20°C due to I h activation. Our hypothesis was supported when the starting level of I h was enhanced by elevating cAMP because cold activation was converted to more ordinary cold inhibition. These findings indicate that situations leading to enhancement of I h facilitate firing at 20°C, yet the hyperpolarization associated with inhibiting a depolarizing cation current by cooling blunts the net V m response to cooling to oppose normal cold-depolarizing factors. This suggests that the influence of I h activation state on neuronal firing varies in the poikilothermic neuronal environment. Copyright © 2015 the American Physiological Society.
Variable Cold-Induced Brown Adipose Tissue Response to Thyroid Hormone Status
Hasselgren, Per-Olof; Glasgow, Allison; Doyle, Ashley N.; Lee, Alice J.; Fox, Peter; Gautam, Shiva; Hennessey, James V.; Kolodny, Gerald M.
2017-01-01
Background: In addition to its role in adaptive thermogenesis, brown adipose tissue (BAT) may protect from weight gain, insulin resistance/diabetes, and metabolic syndrome. Prior studies have shown contradictory results regarding the influence of thyroid hormone (TH) levels on BAT volume and activity. The aim of this pilot study was to gain further insights regarding the effect of TH treatment on BAT function in adult humans by evaluating the BAT mass and activity prospectively in six patients, first in the hypothyroid and then in the thyrotoxic phase. Methods: The study subjects underwent 18F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) scanning after cold exposure to measure BAT mass and activity while undergoing treatment for differentiated thyroid cancer, first while hypothyroid following TH withdrawal at the time of the radioactive iodine treatment and then three to six months after starting TH suppressive treatment when they were iatrogenically thyrotoxic. Thermogenic and metabolic parameters were measured in both phases. Results: All study subjects had detectable BAT under cold stimulation in both the hypothyroid and thyrotoxic state. The majority but not all (4/6) subjects showed an increase in detectable BAT volume and activity under cold stimulation between the hypothyroid and thyrotoxic phase (total BAT volume: 72.0 ± 21.0 vs. 87.7 ± 16.5 mL, p = 0.25; total BAT activity 158.1 ± 72.8 vs. 189.0 ± 55.5 SUV*g/mL, p = 0.34). Importantly, circulating triiodothyronine was a stronger predictor of energy expenditure changes compared with cold-induced BAT activity. Conclusions: Iatrogenic hypothyroidism lasting two to four weeks does not prevent cold-induced BAT activation, while the use of TH to induce thyrotoxicosis does not consistently increase cold-induced BAT activity. It remains to be determined which physiological factors besides TH play a role in regulating BAT function. PMID:27750020
Variable Cold-Induced Brown Adipose Tissue Response to Thyroid Hormone Status.
Gavrila, Alina; Hasselgren, Per-Olof; Glasgow, Allison; Doyle, Ashley N; Lee, Alice J; Fox, Peter; Gautam, Shiva; Hennessey, James V; Kolodny, Gerald M; Cypess, Aaron M
2017-01-01
In addition to its role in adaptive thermogenesis, brown adipose tissue (BAT) may protect from weight gain, insulin resistance/diabetes, and metabolic syndrome. Prior studies have shown contradictory results regarding the influence of thyroid hormone (TH) levels on BAT volume and activity. The aim of this pilot study was to gain further insights regarding the effect of TH treatment on BAT function in adult humans by evaluating the BAT mass and activity prospectively in six patients, first in the hypothyroid and then in the thyrotoxic phase. The study subjects underwent 18F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) scanning after cold exposure to measure BAT mass and activity while undergoing treatment for differentiated thyroid cancer, first while hypothyroid following TH withdrawal at the time of the radioactive iodine treatment and then three to six months after starting TH suppressive treatment when they were iatrogenically thyrotoxic. Thermogenic and metabolic parameters were measured in both phases. All study subjects had detectable BAT under cold stimulation in both the hypothyroid and thyrotoxic state. The majority but not all (4/6) subjects showed an increase in detectable BAT volume and activity under cold stimulation between the hypothyroid and thyrotoxic phase (total BAT volume: 72.0 ± 21.0 vs. 87.7 ± 16.5 mL, p = 0.25; total BAT activity 158.1 ± 72.8 vs. 189.0 ± 55.5 SUV*g/mL, p = 0.34). Importantly, circulating triiodothyronine was a stronger predictor of energy expenditure changes compared with cold-induced BAT activity. Iatrogenic hypothyroidism lasting two to four weeks does not prevent cold-induced BAT activation, while the use of TH to induce thyrotoxicosis does not consistently increase cold-induced BAT activity. It remains to be determined which physiological factors besides TH play a role in regulating BAT function.
NASA Astrophysics Data System (ADS)
Targino, Admir Créso; Krecl, Patricia; Coraiola, Guilherme Conor
2014-07-01
Air temperature was monitored at 13 sites across the urban perimeter of a Brazilian midsize city in winter 2011. In this study, we show that the urban heat island (UHI) develops only at night and under certain weather conditions, and its intensity depends not only on the site's land cover but also on the meteorological setting. The urban heat island intensity was largest (6.6 °C) under lingering high-pressure conditions, milder (3.0 °C) under cold anticyclones and almost vanished (1.0 °C) during the passage of cold fronts. The cooling rates were calculated to monitor the growth and decay of the UHI over each specific synoptic setting. Over four contiguous days under the effect of a lingering high-pressure event, we observed that the onset of cooling was always at about 2 h before sunset. The reference site attained mean cooling rate of -2.6 °C h-1 at sunset, whilst the maximum urban rate was -1.2 °C h-1. Under a 3-day cold anticyclone episode, cooling also started about 2 h before sunset, and the difference between maximum rural (-2.0 °C h-1) and urban (-1.0 °C h-1) cooling rates diminished. Under cold-front conditions, the cooling rate was homogeneous for all sites and swang about zero throughout the day. The air temperature has a memory effect under lingering high-pressure conditions which intensified the UHI, in addition to the larger heat storage in the urban area. Cold anticyclone conditions promoted the development of the UHI; however, the cold air pool and relatively light winds smoothed out its intensity. Under the influence of cold fronts, the urban fabric had little effect on the city's air temperature field, and the UHI was imperceptible.
Analysis of cold worked holes for structural life extension
NASA Technical Reports Server (NTRS)
Wieland, David H.; Cutshall, Jon T.; Burnside, O. Hal; Cardinal, Joseph W.
1994-01-01
Cold working holes for improved fatigue life of fastener holes are widely used on aircraft. This paper presents methods used by the authors to determine the percent of cold working to be applied and to analyze fatigue crack growth of cold worked fastener holes. An elastic, perfectly-plastic analysis of a thick-walled tube is used to determine the stress field during the cold working process and the residual stress field after the process is completed. The results of the elastic/plastic analysis are used to determine the amount of cold working to apply to a hole. The residual stress field is then used to perform damage tolerance analysis of a crack growing out of a cold worked fastener hole. This analysis method is easily implemented in existing crack growth computer codes so that the cold worked holes can be used to extend the structural life of aircraft. Analytical results are compared to test data where appropriate.
Born, D-P; Hoppe, M W; Lindner, N; Freiwald, J; Holmberg, H-C; Sperlich, B
2014-03-01
Football is played worldwide and players often have to cope with hot and cold temperatures as well as high altitude conditions. The upcoming and past world championships in Brazil, Qatar and South Africa illustrate the necessity for behavioural strategies and adaptation to extreme environmental conditions. When playing football in the heat or cold, special clothing, hydration and nutritional and acclimatisation strategies are vital for high-level performance. When playing at high altitude, the reduced oxygen partial pressure impairs endurance performance and alters the technical and tactical requirements. Special high-altitude adaptation and preparation strategies are essential for football teams based at sea-level in order to perform well and compete successfully. Therefore, the aim of the underlying review is: 1) to highlight the difficulties and needs of football teams competing in extreme environmental conditions, 2) to summarise the thermoregulatory, physiological, neuronal and psychological mechanism, and 3) to provide recommendations for coping with extreme environmental conditions in order to perform at a high level when playing football in the heat, cold and at high altitude. © Georg Thieme Verlag KG Stuttgart · New York.
Northrop Grumman HEC flight coaxial cryocoolers performance
NASA Astrophysics Data System (ADS)
Nguyen, T.; Russo, J.; Basel, G.; Chi, D.; Abelson, L.
2018-05-01
The Northrop Grumman Aerospace Systems (NGAS) has expanded the cryocooler product line to include a single stage High Efficiency Cryocooler (HEC) cooler with a coaxial pulse tube cold head that operates at temperatures down to 45K. The HEC coaxial pulse tube cooler has been adopted by several customers, and has completed acceptance testing to meet program flight requirements. The NGAS TRL 9 HEC is a pulse tube cryocooler with a flexure bearing compressor which has been delivered for a number of flight payloads that are currently operating in space. To date, NGAS has delivered space cryocoolers in several configurations including single stage with a linear cold head and two stage with both linear and coaxial cold heads. The new HEC coaxial cooler uses the same TRL9 HEC compressor with a passive pulse tube cold head, to maintain the flight heritage of the HEC linear cooler. In this paper, we present the flight acceptance test data of the HEC coaxial cryocooler, which includes thermal performance, launch vibration and thermal cycling. The HEC coaxial cooler has demonstrated excellent performance in family with the flight qualified HEC linear cooler. The HEC coaxial cooler provides users with additional flexibility in selecting the cold head configuration to meet their particular applications.
Characterization of Long SiAION Ceramic Tubes for Gun Barrel Applications
2006-06-01
sintering kinetics during the sintering of regions with different starting densities can all lead to the production of tubes with gradients in strength and...variations of dimensions. These gradients and deviations from anticipated dimensions all detract from the ability of the manufactured product to be...characteristics of the tubes can be introduced at various steps in the production process. When the powder is initially loaded to be cold
Strategic Delusions - The Cold Start Doctrine: Proactive Strategy
2016-05-26
recent tactical strike in Myanmar is miscued as a precursor for times to come in the regional context.10 These tactical actions also known as Hot...Attacks Militant Camps in Myanmar , Wall Street Journal, June 10, 2015, accessed August 24, 2015, http://www.wsj.com/articles/indian-army-attacks...militant-camps-in- myanmar -1433927858. 7 imperatives associated with the Indian PAS and its validation through the framework of strategy and the
External Catalyst Breakup Phenomena
1975-09-01
thruster exposure. a Erosion .by a pulsed liquid stream at high velocity. * Thermal shock from liquid quench cooldovn. 9 Erosion resulting from solid...the liquid velocity. During a cold start contact with hydrazine leading to liquid wetting can lead to very high internal pressures as a result ot the...compression and final dilation, suggest benefits from reducing this variable. A . Isolating the catalyst particles from one another so as to avoid high
Apparatus for photocatalytic destruction of internal combustion engine emissions during cold start
Janata, J.; McVay, G.L.; Peden, C.H.; Exarhos, G.J.
1998-07-14
A method and apparatus are disclosed for the destruction of emissions from an internal combustion engine wherein a substrate coated with TiO{sub 2} is exposed to a light source in the exhaust system of an internal combustion engine thereby catalyzing oxidation/reduction reactions between gaseous hydrocarbons, carbon monoxide, nitrogen oxides and oxygen in the exhaust of the internal combustion engine. 4 figs.
Robotic Vehicle Communications Interoperability
1988-08-01
starter (cold start) X X Fire suppression X Fording control X Fuel control X Fuel tank selector X Garage toggle X Gear selector X X X X Hazard warning...optic Sensors Sensor switch Video Radar IR Thermal imaging system Image intensifier Laser ranger Video camera selector Forward Stereo Rear Sensor control...optic sensors Sensor switch Video Radar IR Thermal imaging system Image intensifier Laser ranger Video camera selector Forward Stereo Rear Sensor
2005-01-01
Cold Foam 1% ethylene glycol 1% benzalkonium chloride 1% polyvinylpolypyrrolidone 1% Brij 58 1% Benzyldimethyl tetradecyl ammonium chloride dihydrate...described in this report was authorized by the Defense Threat Reduction Agency. This work was started in December 2003 and completed in March 2004. The...LITERA TURE CITED ..................................................................................... 15 5 FIGURES 1. Rates of Chloride Release in
NASA Astrophysics Data System (ADS)
Li, S. G.; Shi, L.
2014-10-01
The recommendation system for virtual items in massive multiplayer online role-playing games (MMORPGs) has aroused the interest of researchers. Of the many approaches to construct a recommender system, collaborative filtering (CF) has been the most successful one. However, the traditional CFs just lure customers into the purchasing action and overlook customers' satisfaction, moreover, these techniques always suffer from low accuracy under cold-start conditions. Therefore, a novel collaborative filtering (NCF) method is proposed to identify like-minded customers according to the preference similarity coefficient (PSC), which implies correlation between the similarity of customers' characteristics and the similarity of customers' satisfaction level for the product. Furthermore, the analytic hierarchy process (AHP) is used to determine the relative importance of each characteristic of the customer and the improved ant colony optimisation (IACO) is adopted to generate the expression of the PSC. The IACO creates solutions using the Markov random walk model, which can accelerate the convergence of algorithm and prevent prematurity. For a target customer whose neighbours can be found, the NCF can predict his satisfaction level towards the suggested products and recommend the acceptable ones. Under cold-start conditions, the NCF will generate the recommendation list by excluding items that other customers prefer.
Gas Accretion onto a Supermassive Black Hole: A Step to Model AGN Feedback
NASA Astrophysics Data System (ADS)
Nagamine, K.; Barai, P.; Proga, D.
2012-08-01
We study gas accretion onto a supermassive black hole (SMBH) using the 3D SPH code GADGET-3 on scales of 0.1-200 pc. First we test our code with the spherically symmetric, adiabatic Bondi accretion problem. We find that our simulation can reproduce the expected Bondi accretion flow very well for a limited amount of time until the effect of the outer boundary starts to be visible. We also find artificial heating of gas near the inner accretion boundary due to the artificial viscosity of SPH. Second, we implement radiative cooling and heating due to X-rays, and examine the impact of thermal feedback by the central X-ray source. The accretion flow roughly follows the Bondi solution for low central X-ray luminosities; however, the flow starts to exhibit non-spherical fragmentation due to the thermal instability for a certain range of central LX, and a strong overall outflow develops for greater LX. The cold gas develops filamentary structures that fall into the central SMBH, whereas the hot gas tries to escape through the channels in between the cold filaments. Such fragmentation of accreting gas can assist in the formation of clouds around AGN, induce star-formation, and contribute to the observed variability of narrow-line regions.
Giechaskiel, Barouch; Suarez-Bertoa, Ricardo; Lähde, Tero; Clairotte, Michael; Carriero, Massimo; Bonnel, Pierre; Maggiore, Maurizio
2018-06-13
The Horizon 2020 prize for the "Engine Retrofit for Clean Air" aims at reducing the pollution in cities by spurring the development of retrofit technology for diesel engines. A Euro 5 passenger car was retrofitted with an under-floor SCR (Selective Catalytic Reduction) for NO x catalyst in combination with a solid ammonia based dosing system as the NO x reductant. The vehicle was tested both on the road and on the chassis dynamometer under various test cycles and ambient temperatures. The NO x emissions were reduced by 350-1100 mg/km (60-85%) in the laboratory depending on the test cycle and engine conditions (cold or hot start), except at type approval conditions. The reduction for cold start urban cycles was < 75 mg/km (< 15%). The on road and laboratory tests were inline. In some high speed conditions significant increase of ammonia (NH 3 ) and nitrous oxide (N 2 O) were measured. No effect was seen on other pollutants (hydrocarbons, carbon monoxide and particles). The results of the present study show that retrofitting high emitting vehicles can significantly reduce vehicle NO x emissions and ultimately pollution in cities. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
THE EFFECT OF ANISOTROPIC VISCOSITY ON COLD FRONTS IN GALAXY CLUSTERS
DOE Office of Scientific and Technical Information (OSTI.GOV)
ZuHone, J. A.; Markevitch, M.; Kunz, M. W.
2015-01-10
Cold fronts—contact discontinuities in the intracluster medium (ICM) of galaxy clusters—should be disrupted by Kelvin-Helmholtz (K-H) instabilities due to the associated shear velocity. However, many observed cold fronts appear stable. This opens the possibility of placing constraints on microphysical mechanisms that stabilize them, such as the ICM viscosity and/or magnetic fields. We performed exploratory high-resolution simulations of cold fronts arising from subsonic gas sloshing in cluster cores using the grid-based Athena MHD code, comparing the effects of isotropic Spitzer and anisotropic Braginskii viscosity (expected in a magnetized plasma). Magnetized simulations with full Braginskii viscosity or isotropic Spitzer viscosity reduced bymore » a factor f ∼ 0.1 are both in qualitative agreement with observations in terms of suppressing K-H instabilities. The rms velocity of turbulence within the sloshing region is only modestly reduced by Braginskii viscosity. We also performed unmagnetized simulations with and without viscosity and find that magnetic fields have a substantial effect on the appearance of the cold fronts, even if the initial field is weak and the viscosity is the same. This suggests that determining the dominant suppression mechanism of a given cold front from X-ray observations (e.g., viscosity or magnetic fields) by comparison with simulations is not straightforward. Finally, we performed simulations including anisotropic thermal conduction, and find that including Braginskii viscosity in these simulations does not significantly affect the evolution of cold fronts; they are rapidly smeared out by thermal conduction, as in the inviscid case.« less
Rosenfeldt, Franklin; Ou, Ruchong; Salamonsen, Robert; Marasco, Silvana; Zimmet, Adam; Byrne, Joshua; Cosic, Filip; Saxena, Pankaj; Esmore, Donald
2016-11-01
Donation after circulatory death (DCD) represents a potential new source of hearts to increase the donor pool. We showed previously that DCD hearts in Greyhound dogs could be resuscitated and preserved by continuous cold crystalloid perfusion but not by cold static storage and could demonstrate excellent contractile and metabolic function on an in vitro system. In the current study, we demonstrate that resuscitated DCD hearts are transplantable. Donor Greyhound dogs (n = 12) were divided into perfusion (n = 8) and cold static storage (n = 4) groups. General anesthesia was induced and ventilation ceased for 30 minutes to achieve circulatory death. Donor cardiectomy was performed, and for 4 hours the heart was preserved by controlled reperfusion, followed by continuous cold perfusion with an oxygenated crystalloid perfusate or by static cold storage, after which orthotopic heart transplantation was performed. Recovery was assessed over 4 hours by hemodynamic monitoring. During cold perfusion, hearts showed continuous oxygen consumption and low lactate levels, indicating aerobic metabolism. The 8 dogs in the perfusion group were weaned off bypass, and 4 hours after bypass produced cardiac output of 4.73 ± 0.51 liters/min, left ventricular power of 7.63 ± 1.32 J/s, right ventricular power of 1.40 ± 0.43 J/s, and left ventricular fractional area shortening of 39.1% ± 5.2%, all comparable to pre-transplant values. In the cold storage group, 3 of 4 animals could not be weaned from cardiopulmonary bypass, and the fourth exhibited low-level function. Cold crystalloid perfusion, but not cold static storage, can resuscitate and preserve the DCD donor heart in a canine model of heart transplantation, thus rendering it transplantable. Controlled reperfusion and cold crystalloid perfusion have potential for clinical application in DCD transplantation. Copyright © 2016. Published by Elsevier Inc.
A pulse tube cryocooler with a cold reservoir
NASA Astrophysics Data System (ADS)
Zhang, X. B.; Zhang, K. H.; Qiu, L. M.; Gan, Z. H.; Shen, X.; Xiang, S. J.
2013-02-01
Phase difference between pressure wave and mass flow is decisive to the cooling capacity of regenerative cryocoolers. Unlike the direct phase shifting using a piston or displacer in conventional Stirling or GM cryocoolers, the pulse tube cyocooler (PTC) indirectly adjusts the cold phase due to the absence of moving parts at the cold end. The present paper proposed and validated theoretically and experimentally a novel configuration of PTC, termed cold reservoir PTC, in which a reservoir together with an adjustable orifice is connected to the cold end of the pulse tube. The impedance from the additional orifice to the cold end helps to increase the mass flow in phase with the pressure wave at the cold end. Theoretical analyses with the linear model for the orifice and double-inlet PTCs indicate that the cooling performance can be improved by introducing the cold reservoir. The preliminary experiments with a home-made single-stage GM PTC further validated the results on the premise of minor opening of the cold-end orifice.
NASA Astrophysics Data System (ADS)
Fattah-alhosseini, Arash; Naseri, Majid; Gashti, Seyed Omid; Vafaeian, Saeed; Keshavarz, Mohsen K.
2018-06-01
In the present work, influences of the cold deformation on electrochemical and passive response of pure nickel in three solutions with adjusted pH values of 8.5, 9.0, and 9.5 at 298 ± 1 K (25 ± 1 °C) were investigated. A cold deformation process was applied by means of cold rolling. Implementation of the cold deformation process resulted in samples having a finer microstructure. Also, the cold work and grain refinement led to increased hardness. In addition, open-circuit potential and potentiodynamic polarization tests were performed and results showed that corrosion current density was reduced by applying the cold deformation. Moreover, the results of the electrochemical impedance spectroscopy and Mott-Schottky analyses indicated higher corrosion resistance of pure nickel after cold deformation. This behavior is attributed to the growth of much thicker, with less point defects, passive layer on the surface of cold-deformed samples.
Preparation of translationally cold neutral molecules.
Di Domenicantonio, Giulia; Bertsche, Benjamin; Osterwalder, Andreas
2011-01-01
Efforts at EPFL to obtain translationally cold neutral molecules are described. Active deceleration of polar molecules is performed by confining the molecules in moving three-dimensional electrostatic traps, and by appropriately choosing the velocity of those traps. Alternatively, cold molecules can be obtained by velocity filtering. Here, the velocity of the molecules is not changed, but instead the cold molecules are extracted from a thermal sample by using the competition between the electrostatic force and the centrifugal force inside a bent electrostatic guide for polar molecules.
Wiggen, Øystein N; Waagaard, Silje H; Heidelberg, Cecilie T; Oksa, Juha
2013-12-01
This study compared the effects of cold (-14° C) and moderate environments (6° C) on double poling (DP) sprint performance. Wearing modern cross-country ski racing suits, 14 highly trained male cross-country skiers performed a test protocol on a DP ergometer, consisting of a standardized warm-up followed by a 30-second maximal sprint (DP30s) and a 2-minute maximal sprint (DP2min), and after an 8-minute recovery period, another DP30s and DP2min were performed. Finally, the participants performed an incremental DP test to exhaustion. We observed no difference between rectal temperature in cold and moderate conditions. Mean skin temperature (Tskin) was lower in the cold condition; the lowest values being 20.3° C at -14° C and 27.0° C at 6° C. Power output decreased between the first and the second DP30s under both conditions, but the reduction was 4.9% (p < 0.05) greater in the cold condition. Power output decreased by 4.8% (p < 0.05) between the first and second DP2min at -14° C, but we found no difference at 6° C. In the incremental test to exhaustion, there was a 7.2% (p < 0.05) reduction in peak power output and a 7.8% (p < 0.05) lower peak oxygen consumption at -14° C. In conclusion, this study demonstrated that DP sprint performance was lower at -14° C than at 6° C. Tskin and body temperature were lower at -14° C. This may indicate cooling of superficial musculature and may explain the reduced DP sprint performance observed in our study.
Effects of water immersion on posttraining recovery in Australian footballers.
Elias, George P; Varley, Matthew C; Wyckelsma, Victoria L; McKenna, Michael J; Minahan, Clare L; Aughey, Robert J
2012-12-01
The authors investigated the efficacy of a single exposure to 14 min of cold-water immersion (COLD) and contrast water therapy (CWT) on posttraining recovery in Australian football (AF). Fourteen AF players participated in 3 wk of standardized training. After week 1 training, all players completed a passive recovery (PAS). During week 2, COLD or CWT was randomly assigned. Players undertook the opposing intervention in week 3. Repeat-sprint ability (6 × 20 m), countermovement and squat jumps, perceived muscle soreness, and fatigue were measured pretraining and over 48 h posttraining. Immediately posttraining, groups exhibited similar performance and psychometric declines. At 24 h, repeat-sprint time had deteriorated by 4.1% for PAS and 1.0% for CWT but was fully restored by COLD (0.0%). At 24 and 48 h, both COLD and CWT attenuated changes in mean muscle soreness, with COLD (0.6 ± 0.6 and 0.0 ± 0.4) more effective than CWT (1.9 ± 0.7 and 1.0 ± 0.7) and PAS having minimal effect (5.5 ± 0.6 and 4.0 ± 0.5). Similarly, after 24 and 48 h, COLD and CWT both effectively reduced changes in perceived fatigue, with COLD (0.6 ± 0.6 and 0.0 ± 0.6) being more successful than CWT (0.8 ± 0.6 and 0.7 ± 0.6) and PAS having the smallest effect (2.2 ± 0.8 and 2.4 ± 0.6). AF training can result in prolonged physical and psychometric deficits persisting for up to 48 h. For restoring physical-performance and psychometric measures, COLD was more effective than CWT, with PAS being the least effective. Based on these results the authors recommend that 14 min of COLD be used after AF training.
Facchini, Laura; Losito, Ilario; Cataldi, Tommaso R I; Palmisano, Francesco
2018-01-01
A systematic characterization of phosphatidylcholines and phosphatidylethanolamines in mussels of sp Mytilus galloprovincialis was performed by high-efficiency hydrophilic interaction liquid chromatography combined with electrospray ionization and Fourier transform mass spectrometry (FTMS), based on a quadrupole-Orbitrap hybrid spectrometer. The FTMS/MS experiments under high collisional energy dissociation conditions, complemented by low-energy collisionally induced dissociation MS n (n = 2,3) experiments, performed in a linear ion trap mass spectrometer, were exploited for structural elucidation purposes. The described approach led to an unprecedented characterization of the mussel phospholipidome, with 185 phosphatidylcholines and 131 phosphatidylethanolamines species recognized, distributed among diacylic, plasmanylic, and plasmenylic forms. This was the starting point for the evaluation of the effects of season (in particular, of sea temperature) on the profile of those phospholipids. To this aim, a set of mussel samples retrieved from commercial sources in different periods of the year was considered. Principal component analysis revealed a clear separation between samples collected in periods characterized by cold, intermediate, or warm sea temperatures, respectively. In particular, an enrichment in phospholipids containing unsaturated side chains was observed in mussels collected from cold seawaters (winter-early spring), thus confirming the general model previously elaborated to explain the adaptation of marine invertebrates, including some bivalve molluscs, to low temperatures. On the other hand, relevant levels of plasma(e)nylic and acylic phospholipids bearing either saturated or non-methylene-interrupted side chains were found in mussels collected in warm seawaters (typical of summer and early autumn, at Italian latitudes). This finding opened interesting perspectives towards the development of strategies able to prevent global warming-related mussel losses in aquacultural plants. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Vogelaere, P.; Brasseur, M.; Quirion, A.; Leclercq, R.; Laurencelle, L.; Bekaert, S.
1990-03-01
The affect of negative thermal stress on hematological variables at rest, and during submaximal (sub ex) and maximal exercise (max ex) were observed for young males who volunteered in two experimental sessions, performed in cold (0°C) and in normal room temperature (20°C). At rest, hematological variables such as RBC and derivates Hb and Hct were significantly increased ( P<0.05) during cold stress exposure, while plasma volume decreased. The findings of this study suggest that the major factor inducing hypovolemia during low thermal stress can be imputed to local plasma water-shift mechanisms and especially to a transient shift of plasma water from intrato extravascular compartments. Rest values for WBC and platelets (Pla) were also slightly increased during cold stress exposure. However this increase can partly be related to hemoconcentration but also to the cold induced hyperventilation activating the lung circulation. Maximal exhaustive exercise induced, in both experimental temperatures, significant ( P<0.05) increments of RBC, Hb, Hct, and WBC while plasma volume decreased. However, Pla increase was less marked. On the other hand, cold stress raised slightly the observed variations of the different hematological variables. Submaximal exercise induced a similar, though non-significant, pattern for the different hematological variables in both experimental conditions. Observed plasma volume (Δ PV%) reduction appears during exercise. However cold stress induced resting plasma volume variations that are transferred at every exercise level. Neither exercise nor cold inducement significantly modified the hematological indices (MCH, MCV, MCHC). In conclusion hematological variables are affected by cold stress exposure, even when subjects perform a physical activity.
Cold startup and low temperature performance of the Brayton cycle electrical subsystem
NASA Technical Reports Server (NTRS)
Vrancik, J. E.; Bainbridge, R. C.
1971-01-01
Cold performance tests and startup tests were conducted on the Brayton-cycle inverter, motor-driven pump, dc supply, speed control with parasitic load resistor and the Brayton control system. These tests were performed with the components in a vacuum and mounted on coldplates. A temperature range of ?25 to -50 C was used for the tests. No failures occurred, and component performance gave no indication that there would be any problem with the safe operation of the Brayton power generating system.
Hossack, Blake R.; Corn, P. Stephen; , Winsor H. Lowe; , Molly A. H. Webb; , Mariah J. Talbott; , Kevin M. Kappenman
2013-01-01
5. Our experiments with a cold-water species show that population-level performance varies across small geographic scales and is linked to local environmental heterogeneity. This variation could influence the rate and mode of species-level responses to climate change, both by facilitating local persistence in the face of change
Transcriptome Dynamics in Mango Fruit Peel Reveals Mechanisms of Chilling Stress
Sivankalyani, Velu; Sela, Noa; Feygenberg, Oleg; Zemach, Hanita; Maurer, Dalia; Alkan, Noam
2016-01-01
Cold storage is considered the most effective method for prolonging fresh produce storage. However, subtropical fruit is sensitive to cold. Symptoms of chilling injury (CI) in mango include red and black spots that start from discolored lenticels and develop into pitting. The response of ‘Keitt’ mango fruit to chilling stress was monitored by transcriptomic, physiological, and microscopic analyses. Transcriptomic changes in the mango fruit peel were evaluated during optimal (12°C) and suboptimal (5°C) cold storage. Two days of chilling stress upregulated genes involved in the plant stress response, including those encoding transmembrane receptors, calcium-mediated signal transduction, NADPH oxidase, MAP kinases, and WRKYs, which can lead to cell death. Indeed, cell death was observed around the discolored lenticels after 19 days of cold storage at 5°C. Localized cell death and cuticular opening in the lumen of discolored lenticels were correlated with increased general decay during shelf-life storage, possibly due to fungal penetration. We also observed increased phenolics accumulation around the discolored lenticels, which was correlated with the biosynthesis of phenylpropanoids that were probably transported from the resin ducts. Increased lipid peroxidation was observed during CI by both the biochemical malondialdehyde method and a new non-destructive luminescent technology, correlated to upregulation of the α-linolenic acid oxidation pathway. Genes involved in sugar metabolism were also induced, possibly to maintain osmotic balance. This analysis provides an in-depth characterization of mango fruit response to chilling stress and could lead to the development of new tools, treatments and strategies to prolong cold storage of subtropical fruit. PMID:27812364
Influence of minor geometric features on Stirling pulse tube cryocooler performance
NASA Astrophysics Data System (ADS)
Fang, T.; Spoor, P. S.; Ghiaasiaan, S. M.; Perrella, M.
2017-12-01
Minor geometric features and imperfections are commonly introduced into the basic design of multi-component systems to simplify or reduce the manufacturing expense. In this work, the cooling performance of a Stirling type cryocooler was tested in different driving powers, cold-end temperatures and inclination angles. A series of Computational Fluid Dynamics (CFD) simulations based on a prototypical cold tip was carried out. Detailed CFD model predictions were compared with the experiment and were used to investigate the impact of such apparently minor geometric imperfections on the performance of Stirling type pulse tube cryocoolers. Predictions of cooling performance and gravity orientation sensitivity were compared with experimental results obtained with the cryocooler prototypes. The results indicate that minor geometry features in the cold tip assembly can have considerable negative effects on the gravity orientation sensitivity of a pulse tube cryocooler.
Rutting performance of cold bituminous emulsion mixtures
NASA Astrophysics Data System (ADS)
Arshad, Ahmad Kamil; Ali, Noor Azilatom; Shaffie, Ekarizan; Hashim, Wardati; Rahman, Zanariah Abd
2017-10-01
Cold Bituminous Emulsion Mixture (CBEM) is an environmentally friendly alternative to hot mix asphalt (HMA) for road surfacing, due to its low energy requirements. However, CBEM has generally been perceived to be less superior in performance, compared to HMA. This paper details a laboratory study on the rutting performance of CBEM. The main objective of this study is to determine the Marshall properties of CBEM and to evaluate the rutting performance. The effect of cement in CBEM was also evaluated in this study. The specimens were prepared using Marshall Mix Design Method and rutting performance was evaluated using the Asphalt Pavement Analyzer (APA). Marshall Properties were analysed to confirm compliance with the PWD Malaysia's specification requirements. The rutting performance for specimens with cement was also found to perform better than specimens without cement. It can be concluded that Cold Bituminous Emulsion Mixtures (CBEM) with cement is a viable alternative to Hot Mix Asphalt (HMA) as their Marshall Properties and performance obtained from this study meets the requirements of the specifications. It is recommended that further study be conducted on CBEM for other performance criteria such as moisture susceptibility and fatigue.
Uhlig, Florian; Muth, Claus-Martin; Tetzlaff, Kay; Koch, Andreas; Leberle, Richard; Georgieff, Michael; Winkler, Bernd E
2014-06-01
Full-face-masks (FFM) prevent the diver's face from cold and can support nasal breathing underwater. The aim of the study was to evaluate the effect of the use of FFMs on lung function and wellbeing. Twenty-one, healthy, non-asthmatic divers performed two cold-water dives (4⁰C, 25 min, 10 metres' depth) - one with a FFM and the other with a standard scuba regulator (SSR). Spirometry was performed before and after each dive and well-being and cold sensation were assessed after the dives. Significant decreases in forced vital capacity (FVC), forced expiratory volume in one second (FEV₁) and midexpiratory flow at 75% of FVC (MEF₇₅) occurred after both FFM and SSR dives. Changes in FVC and FEV₁ did not differ significantly between FFM and SSR dives. However, the mid-expiratory flows measured at 50% and 25% of FVC (MEF₅₀ and MEF₂₅) were significantly lower 10 minutes after the FFM dive compared to 10 minutes after the SSR dive. The wellbeing and cold sensation of the divers were significantly improved with FFM dives compared to SSR dives. Cold-water dives during wintertime can be associated with airway narrowing. During cold-water dives, the use of a FFM appears to reduce the cold sensation and enhance the well-being of the divers. However, a FFM does not appear to prevent airway narrowing in healthy, non-asthmatic subjects.
Changes in Landing Mechanics after Cold-Water Immersion
ERIC Educational Resources Information Center
Wang, He; Toner, Michael M.; Lemonda, Thomas J.; Zohar, Mor
2010-01-01
The purpose of this study was to investigate the influence of cold-water immersion on kinematics and kinetics during a drop-landing task. On four separate occasions, 9 men performed drop-landings from a 0.6-m platform to a force platform following 30-min immersion to the hip-joint in thermoneutral water (control; 34 [degrees]C) and in cold water…
Burtscher, Martin; Kofler, Philipp; Gatterer, Hannes; Faulhaber, Martin; Philippe, Marc; Fischer, Kathrin; Walther, Rebekka; Herten, Anne
2012-11-01
To study protective effects of windbreaker jacket and pants during exercise in the cold. Randomized pilot study. Climate chamber. Nine well-trained (V[Combining Dot Above]O2max 61.7 ± 6.6 mL/min/kg) sport students (6 male and 3 female participants). Subjects started walking for 1 hour in a climate chamber (0°C ambient temperature and wind speed of 10 km/h) at 70% V[Combining Dot Above]O2max wearing gloves, a T-shirt, and shorts. Then, the walking speed was reduced to 30% V[Combining Dot Above]O2max for an additional 60 minutes or until core temperature dropped below 35.5°C. Subsequently, 3 groups of 3 participants continued walking without change of clothing or obtaining additionally a cap and a windbreaker jacket or windbreaker jacket and pants. Core and skin temperature, thermal comfort. The main findings of this study were that exercising at 70% V[Combining Dot Above]O2max in the cold was sufficient to prevent hypothermia and that during low-intensity exercise (30% V[Combining Dot Above]O2max), the combined use of a polyester cap, lightweight windbreaker jacket, and pants was necessary to increase a prehypothermic core temperature. We strongly recommend taking a cap, windbreaker jacket, and pants for the prevention of hypothermia during exhaustive walking or running in cold weather conditions.
Yang, Xukai; Wang, Dehe; Zhu, Feng; Yang, Ning; Hou, Zhuocheng; Ning, Zhonghua
2018-01-01
Selection for cold tolerance in chickens is important for improving production performance and animal welfare. The identification of chicken breeds with higher cold tolerance and production performance will help to target candidates for the selection. The thyroid gland plays important roles in thermal adaptation, and its function is influenced by breed differences and transcriptional plasticity, both of which remain largely unknown in the chicken thyroid transcriptome. In this study, we subjected Bashang Long-tail (BS) and Rhode Island Red (RIR) chickens to either cold or warm environments for 21 weeks and investigated egg production performance, body weight changes, serum thyroid hormone concentrations, and thyroid gland transcriptome profiles. RIR chickens had higher egg production than BS chickens under warm conditions, but BS chickens produced more eggs than RIRs under cold conditions. Furthermore, BS chickens showed stable body weight gain under cold conditions while RIRs did not. These results suggested that BS breed is a preferable candidate for cold-tolerance selection and that the cold adaptability of RIRs should be improved in the future. BS chickens had higher serum thyroid hormone concentrations than RIRs under both environments. RNA-Seq generated 344.3 million paired-end reads from 16 sequencing libraries, and about 90% of the processed reads were concordantly mapped to the chicken reference genome. Differential expression analysis identified 46–1,211 genes in the respective comparisons. With regard to breed differences in the thyroid transcriptome, BS chickens showed higher cell replication and development, and immune response-related activity, while RIR chickens showed higher carbohydrate and protein metabolism activity. The cold environment reduced breed differences in the thyroid transcriptome compared with the warm environment. Transcriptional plasticity analysis revealed different adaptive responses in BS and RIR chickens to cope with the cold, and showed higher responsiveness in BS compared with RIR chickens, suggesting greater adaptability of the thyroid in BS chickens. Moreover, 10,053 differential splicing events were revealed among the groups, with RNA splicing and processing, gene expression, transport, and metabolism being the main affected biological processes, identifying a valuable alternative splicing repertoire for the chicken thyroid. A short isoform of TPO (encoding thyroid peroxidase) containing multiple open reading frames was generated in both breeds by skipping exons 4 and 5 in the cold environment. These findings provide novel clues for future studies of the molecular mechanisms underlying cold adaptation and/or acclimation in chickens. PMID:29320582
Xie, Shanshan; Yang, Xukai; Wang, Dehe; Zhu, Feng; Yang, Ning; Hou, Zhuocheng; Ning, Zhonghua
2018-01-01
Selection for cold tolerance in chickens is important for improving production performance and animal welfare. The identification of chicken breeds with higher cold tolerance and production performance will help to target candidates for the selection. The thyroid gland plays important roles in thermal adaptation, and its function is influenced by breed differences and transcriptional plasticity, both of which remain largely unknown in the chicken thyroid transcriptome. In this study, we subjected Bashang Long-tail (BS) and Rhode Island Red (RIR) chickens to either cold or warm environments for 21 weeks and investigated egg production performance, body weight changes, serum thyroid hormone concentrations, and thyroid gland transcriptome profiles. RIR chickens had higher egg production than BS chickens under warm conditions, but BS chickens produced more eggs than RIRs under cold conditions. Furthermore, BS chickens showed stable body weight gain under cold conditions while RIRs did not. These results suggested that BS breed is a preferable candidate for cold-tolerance selection and that the cold adaptability of RIRs should be improved in the future. BS chickens had higher serum thyroid hormone concentrations than RIRs under both environments. RNA-Seq generated 344.3 million paired-end reads from 16 sequencing libraries, and about 90% of the processed reads were concordantly mapped to the chicken reference genome. Differential expression analysis identified 46-1,211 genes in the respective comparisons. With regard to breed differences in the thyroid transcriptome, BS chickens showed higher cell replication and development, and immune response-related activity, while RIR chickens showed higher carbohydrate and protein metabolism activity. The cold environment reduced breed differences in the thyroid transcriptome compared with the warm environment. Transcriptional plasticity analysis revealed different adaptive responses in BS and RIR chickens to cope with the cold, and showed higher responsiveness in BS compared with RIR chickens, suggesting greater adaptability of the thyroid in BS chickens. Moreover, 10,053 differential splicing events were revealed among the groups, with RNA splicing and processing, gene expression, transport, and metabolism being the main affected biological processes, identifying a valuable alternative splicing repertoire for the chicken thyroid. A short isoform of TPO (encoding thyroid peroxidase) containing multiple open reading frames was generated in both breeds by skipping exons 4 and 5 in the cold environment. These findings provide novel clues for future studies of the molecular mechanisms underlying cold adaptation and/or acclimation in chickens.
Chemosynthesis-based communities through time
NASA Astrophysics Data System (ADS)
Kaim, Andrzej
2010-05-01
The discovery of chemosynthesis-based communities in late 1970s was probably one of the biggest surprises in the marine biology of 20th century. There are three basic types of locations where such communities may develop: hydrothermal vents, cold seeps, and vertebrate falls. Also sunken wood communities are partially chemosynthetically fueled. Reports of these unusual aggregation of benthic animals in the deep sea prompted a quest for their counterparts in the fossil record. Soon it has been revealed that a number of exotic carbonate rocks rich in fossils in otherwise siliciclastic deep water facies could easily be interpreted as a result of ancient cold seeps' activity. Later on also numerous hot vent, whale fall, and sunken wood associations have been described from the geological past. The earliest-known chemosynthesis-based association containing metazoan animals has been described from Silurian of Ural Mountains. This and the other Paleozoic chemosynthesis-based associations are dominated by worm tubes, mollusks (monoplacophorans, bivalves, and gastropods), and brachiopods. Nothing is known from the period encompassing Permian and Triassic and the Mesozoic record of chemosynthesis-based communities starts in Jurassic. The Lower Jurassic hydrothermal vent association from California consists of worm tubes, gastropods, and brachiopods which are not really comparable to their counterparts from Recent chemosynthesis-based communities. First associations composed of fossils recollecting animals from the Recent chemosynthesis-based communities appear in Late Jurassic. Oxfordian cold seep deposits from France are dominated by lucinid bivalves and similar deposits from Tithonian of Alexander Island in the Antarctic are known to contain lucinids and mass aggregations of hokkaidoconchids-extinct group of gastropods related to Recent Provannidae. Early Cretaceous is an epoch of rhynchonellide brachiopod Peregrinella which occurs worldwide abundantly at hydrocarbon seep sites where it is associated by lucinid and modiomorphid bivalves, hokkaidoconchids and gastropods which are not clearly related to any of the groups thriving nowadays in chemosynthesis-based communities. Earliest report of alleged neomphalid gastropod also comes from the same epoch. In the Late Cretaceous Peregrinella has disappeared while the bivalves started to dominate cold seep environments. Apart from large lucinids and still present modiomorphids also solemyids, thyasirids, and manzanellids became locally abundant. Several taxa of gastropods known also from Recent chemosynthesis-based communities have appeared at that time. It includes true provannids, acmaeid limpets, collonins, and cataegins. Also from the Late Cretaceous earliest-known sunken wood association containing xylophagainin ship worms has been described. Recently it has been shown that chemosynthesis-based communities could also develop on Late Cretaceous plesiosaur falls. Oligocene and Eocene chemosynthesis-based communities are known from numerous cold seep carbonates and wood and whale fall localities in North Pacific Region. Earliest occurrences of vesicomyids are known from Oligocene seep carbonates while earliest mytilids have been reported from from whale and wood falls from Eocene of the US Pacific Coast. Both groups dominate chemosynthesis-based communities from Miocene onward. Starting from Miocene the chemosynthesis-based associations have a modern composition although several groups of mollusks (e.g. majority of neomphalid gastropods and large symbiotic provannids) extremely common in Recent hydrothermal vents are still unknown from the fossil record.
Wiggen, Øystein Nordrum; Heen, Sigri; Færevik, Hilde; Reinertsen, Randi Eidsmo
2011-01-01
The purpose of this study was to investigate manual performance and thermal responses during low work intensity in persons wearing standard protective clothing in the petroleum industry when they were exposed to a range of temperatures (5, -5, -15 and -25℃) that are relevant to environmental conditions for petroleum industry personnel in northern regions. Twelve men participated in the study. Protective clothing was adjusted for the given cold exposure according to current practices. The subjects performed manual tests five times under each environmental condition. The manual performance test battery consisted of four different tests: tactile sensation (Semmes-Weinstein monofilaments), finger dexterity (Purdue Pegboard), hand dexterity (Complete Minnesota dexterity test) and grip strength (grip dynamometer). We found that exposure to -5℃ or colder lowered skin and body temperatures and reduced manual performance during low work intensity. In conclusion the current protective clothing at a given cold exposure is not adequate to maintain manual performance and thermal balance for petroleum workers in the high north.
McCarthy, Avina; Mulligan, James; Egaña, Mikel
2016-11-01
A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (P peak ) and 30 s at 90% P peak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P < 0.05) longer during Ex2 following the 5- and 10-min cold-water immersions (7.2 ± 3.5 min and 7.3 ± 3.3 min, respectively) compared with passive rest (5.8 ± 3.1 min). Core temperature, heart rate, and rates of perceived exertion were significantly (P < 0.05) lower during most periods of Ex2 after both cold-water immersions compared with passive rest. The time constant of phase II oxygen uptake response during the 85% VT bout of Ex2 was not different among the 3 conditions. A postexercise, 5- to 10-min cold-water immersion increases subsequent intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.
Resolution of Serologic Problems Due to Cold Agglutinins in Chronic Lymphocytic Leukemia.
Javed, Rizwan; Datta, Suvro Sankha; Basu, Sabita; Chakrapani, Anupam
2016-06-01
Autoimmune hemolytic anemia can be classified depending on presence of warm, cold or mixed type of autoantibodies that are directed against antigens on the red blood cell surface. Here we report a case of pathological cold agglutinin disease which was eventually detected due to blood group discrepancy. A request was sent to the blood bank for two units of packed red cells in a diagnosed case of CLL which showed type IV discrepancy during blood grouping.The discrepancy was subsequently resolved after warm saline washing of red cells along with repetition of reverse grouping with pre-warmed serum. The direct antiglobulin test was positive and revealed autoanibodies against C3b/C3d only. Indirect antiglobulin test was performed with 3-cell panel in a polyspecific gel card (IgG+C3d) showed a pan-reactive pattern along with a positive autocontrol. Subsequently a cold agglutinin titration was performed and titers of 1024 at 4 °C; titer of 2 at room temperature were detected. Dithiothreitol (DTT) treatment of serum was undertaken and IgM type of autoantibody was detected in this case confirming a case of secondary cold agglutinin disease in this patient. Two units of red cells were transfused to this patient after successfully performing cross-match with pre-warmed serum. It was advised from the blood bank that the blood should be transfused slowly through a blood-warmer and patient should be kept in warm condition to avoid in-vivo hemolysis due to high titer of cold agglutinin. The transfusion was uneventful and patient is on regular follow-up till now. Thus we concluded that serological discrepancies observed in blood bank can successfully guide the bedside transfusion protocol in case of cold agglutinin disease.
Automotive and Construction Equipment for Arctic Use: Heating and Cold Starting
1991-04-01
heater. Catalytic combustion heaters similar to that shown in Figure 12 produce flameless heat using gasoline, benzene or a similar fuel and have... combustion chamber; physical scientist, is a • engine compartment air; and member of CRREL’s * personnel and cargo compartments. Applied Research Wind...component warping and thermal cracking. When coolant is pumped, heat is not only provided to the cylinders, thereby warming the combustion cha iber and the
NASA Astrophysics Data System (ADS)
Wang, H. T.; Chen, T. T.; Yan, C.; Pan, H.
2018-05-01
For App recommended areas of mobile phone software, made while using conduct App application recommended combined weighted Slope One algorithm collaborative filtering algorithm items based on further improvement of the traditional collaborative filtering algorithm in cold start, data matrix sparseness and other issues, will recommend Spark stasis parallel algorithm platform, the introduction of real-time streaming streaming real-time computing framework to improve real-time software applications recommended.
2013-03-01
behind a low ground pressure tractor, b) leveling with snow planes, and c) repeating the process in 0.3 m lifts. Cold sink times between each...Antarctica started in 1957 with Opera- tion Deep Freeze at Byrd and South Pole Stations and ran until 1962. (During this time McMurdo had a runway...independent turning tires with the ability to compact uniformly across a surface. This type of equipment was best suited for deep compaction because of
The Inner Cold War: State Party Control and East German Society
2014-06-01
explain: “The means of exerting pressure— existentially , psychologically, and morally—were so comprehensive that they had to seriously affect most...with a very different ideology and in principle far more humanistic set of goals, yet with a comparable disregard for individual human rights and...the universities were far too focused upon humanistic research for the Party’s taste,”185 and prompted reforms in these areas starting in 1951. The
NASA Technical Reports Server (NTRS)
Martini, W. R.
1981-01-01
A series of computer programs are presented with full documentation which simulate the transient behavior of a modern 4 cylinder Siemens arrangement Stirling engine with burner and air preheater. Cold start, cranking, idling, acceleration through 3 gear changes and steady speed operation are simulated. Sample results and complete operating instructions are given. A full source code listing of all programs are included.
Time-of-Day Effects on Metabolic and Clock-Related Adjustments to Cold.
Machado, Frederico Sander Mansur; Zhang, Zhi; Su, Yan; de Goede, Paul; Jansen, Remi; Foppen, Ewout; Coimbra, Cândido Celso; Kalsbeek, Andries
2018-01-01
Daily cyclic changes in environmental conditions are key signals for anticipatory and adaptive adjustments of most living species, including mammals. Lower ambient temperature stimulates the thermogenic activity of brown adipose tissue (BAT) and skeletal muscle. Given that the molecular components of the endogenous biological clock interact with thermal and metabolic mechanisms directly involved in the defense of body temperature, the present study evaluated the differential homeostatic responses to a cold stimulus at distinct time-windows of the light/dark-cycle. Male Wistar rats were subjected to a single episode of 3 h cold ambient temperature (4°C) at one of 6 time-points starting at Zeitgeber Times 3, 7, 11, 15, 19, and 23. Metabolic rate, core body temperature, locomotor activity (LA), feeding, and drinking behaviors were recorded during control and cold conditions at each time-point. Immediately after the stimulus, rats were euthanized and both the soleus and BAT were collected for real-time PCR. During the light phase (i.e., inactive phase), cold exposure resulted in a slight hyperthermia ( p < 0.001). Light phase cold exposure also increased metabolic rate and LA ( p < 0.001). In addition, the prevalence of fat oxidative metabolism was attenuated during the inactive phase ( p < 0.001). These metabolic changes were accompanied by time-of-day and tissue-specific changes in core clock gene expression, such as DBP ( p < 0.0001) and REV-ERBα ( p < 0.01) in the BAT and CLOCK ( p < 0.05), PER2 ( p < 0.05), CRY1 ( p < 0.05), CRY2 ( p < 0.01), and REV-ERBα ( p < 0.05) in the soleus skeletal muscle. Moreover, genes involved in substrate oxidation and thermogenesis were affected in a time-of-day and tissue-specific manner by cold exposure. The time-of-day modulation of substrate mobilization and oxidation during cold exposure provides a clear example of the circadian modulation of physiological and metabolic responses. Interestingly, after cold exposure, time-of-day mostly affected circadian clock gene expression in the soleus muscle, despite comparable changes in LA over the light-dark-cycle. The current findings add further evidence for tissue-specific actions of the internal clock in different peripheral organs such as skeletal muscle and BAT.
Organics on Fe-Silicate Grains: Potential Mimicry of Meteoritic Processes?
NASA Technical Reports Server (NTRS)
Johnson, N. M.; Nuth, J. A., III; Cody, G. D.
2004-01-01
Currently, it is unknown what exact process or combination of processes produced organics that are found in meteorites or are detected in comets and nebulas. One particular process that forms organics involves Fischer-Tropsch type (FTT) reactions. Fischer-Tropsch type reactions produce hydrocarbons by hydrogenating carbon monoxide via catalytic reactions. The overall reaction is shown. The products of these reactions have been studied using natural catalysts and calculations of the efficiency of FTT synthesis in the Solar Nebula suggest that these types of reactions could make significant contributions to the composition of material near three AU. We use FTT synthesis to coat amorphous Fesilicate grains with organic material to simulate the chemistry in the early Solar Nebula. We used lab-synthesized amorphous Fe-silicate grains for the catalyst because they might better simulate the starting materials found in protostellar nebulas. A brief description of the synthesis of these grains is given in Experiments. This work is different from previous studies because we focus here on the carbonaceous material deposited on the grains. In our experiments, we roughly simulate a model of the nebular environment where grains are successively transported from hot to cold regions of the nebula. In other words, the starting cold regions of the nebula. In other words, the starting gases and FTT products are continuously circulated through the grains at high temperature with intervals of cooling. Overall, organics generated in this manner could represent the carbonaceous material incorporated into comets and meteorites. We present the analyses of the organics produced using pyrolysis gas chromatography mass spectrometry (GCMS) and compare the results with those organics found in the Murchison meteorite.
International workshop on cold neutron sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, G.J.; West, C.D.
1991-08-01
The first meeting devoted to cold neutron sources was held at the Los Alamos National Laboratory on March 5--8, 1990. Cosponsored by Los Alamos and Oak Ridge National Laboratories, the meeting was organized as an International Workshop on Cold Neutron Sources and brought together experts in the field of cold-neutron-source design for reactors and spallation sources. Eighty-four people from seven countries attended. Because the meeting was the first of its kind in over forty years, much time was spent acquainting participants with past and planned activities at reactor and spallation facilities worldwide. As a result, the meeting had more ofmore » a conference flavor than one of a workshop. The general topics covered at the workshop included: Criteria for cold source design; neutronic predictions and performance; energy deposition and removal; engineering design, fabrication, and operation; material properties; radiation damage; instrumentation; safety; existing cold sources; and future cold sources.« less
Galbiati, Silvia; Monguzzi, Alessandra; Damin, Francesco; Soriani, Nadia; Passiu, Marianna; Castellani, Carlo; Natacci, Federica; Curcio, Cristina; Seia, Manuela; Lalatta, Faustina; Chiari, Marcella; Ferrari, Maurizio; Cremonesi, Laura
2016-07-01
Until now, non-invasive prenatal diagnosis of genetic diseases found only limited routine applications. In autosomal recessive diseases, it can be used to determine the carrier status of the fetus through the detection of a paternally inherited disease allele in cases where maternal and paternal mutated alleles differ. Conditions for non-invasive identification of fetal paternally inherited mutations in maternal plasma were developed by two independent approaches: coamplification at lower denaturation temperature-PCR (COLD-PCR) and highly sensitive microarrays. Assays were designed for identifying 14 mutations, 7 causing β-thalassaemia and 7 cystic fibrosis. In total, 87 non-invasive prenatal diagnoses were performed by COLD-PCR in 75 couples at risk for β-thalassaemia and 12 for cystic fibrosis. First, to identify the more appropriate methodology for the analysis of minority mutated fetal alleles in maternal plasma, both fast and full COLD-PCR protocols were developed for the most common Italian β-thalassaemia Cd39 and IVSI.110 mutations. In 5 out of 31 samples, no enrichment was obtained with the fast protocol, while full COLD-PCR provided the correct fetal genotypes. Thus, full COLD-PCR protocols were developed for all the remaining mutations and all analyses confirmed the fetal genotypes obtained by invasive prenatal diagnosis. Microarray analysis was performed on 40 samples from 28 couples at risk for β-thalassaemia and 12 for cystic fibrosis. Results were in complete concordance with those obtained by both COLD-PCR and invasive procedures. COLD-PCR and microarray approaches are not expensive, simple to handle, fast and can be easily set up in specialised clinical laboratories where prenatal diagnosis is routinely performed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Morenilla-Palao, Cruz; Luis, Enoch; Fernández-Peña, Carlos; Quintero, Eva; Weaver, Janelle L.; Bayliss, Douglas A.; Viana, Félix
2017-01-01
Summary Animals sense cold ambient temperatures through the activation of peripheral thermoreceptors that express TRPM8, a cold- and menthol-activated ion channel. These receptors can discriminate a very wide range of temperatures from innocuous to noxious. The molecular mechanism responsible for the variable sensitivity of individual cold receptors to temperature is unclear. To address this question, we performed a detailed ion channel expression analysis of cold sensitive neurons, combining BAC transgenesis with a molecular profiling approach in FACS purified TRPM8 neurons. We found that TASK-3 leak potassium channels are highly enriched in a subpopulation of these sensory neurons. The thermal threshold of TRPM8 cold neurons is decreased during TASK-3 blockade and in mice lacking TASK-3 and, most importantly, these mice display hypersensitivity to cold. Our results demonstrate a novel role of TASK-3 channels in thermosensation, showing that a channel-based combinatorial strategy in TRPM8 cold thermoreceptors leads to molecular specialization and functional diversity. PMID:25199828
Memantine effects on liver and adrenal gland of rats exposed to cold stress
2011-01-01
Background Memantine attenuates heart stress due cold stress, however, no study focused its effects on liver and adrenal gland. We evaluated its effects on lipid depletion in adrenal gland and glycogen depletion in liver of rats exposed to cold stress. Methods Male rats divided into 4 groups: 1)Control (CON); 2)Memantine (MEM); 3)Induced cold stress (IH) and; 4)Induced cold stress memantine (IHF). Memantine were administrated by gavage (20 mg/kg/day) during eight days. Cold stress were performed during 4 hours once at - 8°C. Lipid and glycogen depletion were presented as its intensity levels. Results Rats exposed to cold stress presented the highest glycogen (p < 0.001) and lipid depletion (p < 0.001) in liver and adrenal gland, respectively. We noted that memantine significantly reduced lipid depletion in adrenal gland and glycogen depletion in liver. Conclusion Memantine prevented glycogen depletion in liver and lipid depletion in adrenal gland of rats under a cold stress condition. PMID:21255456
The Impact of Different Environmental Conditions on Cognitive Function: A Focused Review
Taylor, Lee; Watkins, Samuel L.; Marshall, Hannah; Dascombe, Ben J.; Foster, Josh
2016-01-01
Cognitive function defines performance in objective tasks that require conscious mental effort. Extreme environments, namely heat, hypoxia, and cold can all alter human cognitive function due to a variety of psychological and/or biological processes. The aims of this Focused Review were to discuss; (1) the current state of knowledge on the effects of heat, hypoxic and cold stress on cognitive function, (2) the potential mechanisms underpinning these alterations, and (3) plausible interventions that may maintain cognitive function upon exposure to each of these environmental stressors. The available evidence suggests that the effects of heat, hypoxia, and cold stress on cognitive function are both task and severity dependent. Complex tasks are particularly vulnerable to extreme heat stress, whereas both simple and complex task performance appear to be vulnerable at even at moderate altitudes. Cold stress also appears to negatively impact both simple and complex task performance, however, the research in this area is sparse in comparison to heat and hypoxia. In summary, this focused review provides updated knowledge regarding the effects of extreme environmental stressors on cognitive function and their biological underpinnings. Tyrosine supplementation may help individuals maintain cognitive function in very hot, hypoxic, and/or cold conditions. However, more research is needed to clarify these and other postulated interventions. PMID:26779029
Field Performance of Inverter-Driven Heat Pumps in Cold Climates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williamson, James; Aldrich, Robb
2015-08-19
Traditionally, air-source heat pumps (ASHPs) have been used more often in warmer climates; however, some new ASHPs are gaining ground in colder areas. These systems operate at subzero (Fahrenheit) temperatures and many do not include backup electric resistance elements. There are still uncertainties, however, about capacity and efficiency in cold weather. Also, questions such as “how cold is too cold?” do not have clear answers. These uncertainties could lead to skepticism among homeowners; poor energy savings estimates; suboptimal system selection by heating, ventilating, and air-conditioning contractors; and inconsistent energy modeling. In an effort to better understand and characterize the heatingmore » performance of these units in cold climates, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven, ductless ASHPs across the Northeast. Operating data were collected for three Mitsubishi FE18 units, three Mitsubishi FE12 units, and one Fujitsu 15RLS2 unit. The intent of this research was to assess heat output, electricity consumption, and coefficients of performance (COPs) at various temperatures and load conditions. This assessment was accomplished with long- and short-term tests that measured power consumption; supply, return, and outdoor air temperatures; and airflow through the indoor fan coil.« less
Laser versus cold instruments for microlaryngoscopic surgery.
Zeitels, S M
1996-05-01
Controversy has arisen concerning the merits of the CO2 laser in microlaryngoscopic surgery because of the potentially harmful effects that the injudicious application of the laser could have on voice production. In an effort to develop a logical approach to instrument selection, the author examined the use of both cold instruments and the CO2 laser in the treatment of various benign and malignant lesions. A retrospective review of 307 microlaryngeal procedures performed over a 3-year period revealed that 263 (86%) were glottal and 44 (14%) were supraglottal. Of the 263 glottal procedures, 203 (77%) employed cold instruments alone and 60 (23%) used both cold instruments and the CO2 laser. The laser was used to assist in all 44 supraglottal procedures. Therefore, 203 (66%) of 307 procedures were done with cold instruments alone, and 104 (34%) of 307 procedures were performed using the CO2 laser with cold instruments. Lesions were stratified on the basis of pathology and size, as well as surgical approach. A primary phonomicrosurgical principle in glottal surgery is to maximally preserve the vocal fold's layered microstructure (laminae propria and epithelium). Precise tangential dissection was necessary for achieving this goal. For limited lesions, this dissection was best accomplished with cold instruments alone. The CO2 laser facilitated hemostatic surgical dissection for all supraglottal lesions and for selected larger glottal lesions in which bleeding would obscure visualization of the microanatomy of the musculomembranous vocal fold.
A Case Study of Land Treatment in a Cold Climate-West Dover, Vermont,
1982-12-01
Research & ADA124~i8Engineering Laboratory A case study of land treatment in a cold climate- West Dover, Vermont IT C;0 ~ 03 09 052 CRREL Report 82...44 December 1982 A case study of land treatment in a cold climate- West Dover, Vermont J.R. Bouzoun, D.W. Meals and E.A. Cassell Prepared for OFFICE OF...4. TITLE (end SL : 5. TYPE OF REPORT & PERIOD COVERED A CASE STUDY OF LAND TREATMENT IN A COLD CLIMATE-WEST DOVER, VERMONT 6. PERFORMING ORG. REPORT
Solianik, Rima; Skurvydas, Albertas; Mickevičienė, Dalia; Brazaitis, Marius
2014-10-01
The main aim of this study was to compare the thermal responses and the responses of cognitive and motor functions to intermittent cold stress between males and females. The intermittent cold stress continued until rectal temperature (TRE) reached 35.5°C or for a maximum of 170 min. Thermal response and motor and cognitive performance were monitored. During intermittent cold stress, body temperature variables decreased in all subjects (P < 0.001) and did not differ between sexes. The presence of fast and slow cooling types for participants with similar effect on physiological variables were observed; thus the different rate coolers were grouped together and were attributed only sex specific responses. Overall, TRE cooling rate and cold strain index did not differ between sexes. Maximal voluntary contraction (MVC) decreased after intermittent cold exposure only in males (P < 0.001), whereas changes in muscle electromyography (EMG) activity did not differ between sexes. The effects of intermittent cold stress on electrically evoked muscle properties, spinal (H-reflex), and supraspinal (V-waves) reflexes did not differ between sexes. Intermittent cold-induced cognitive perturbation of attention and memory task performance was greater in males (P < 0.05). Contrary to our expectations, the results of the present study indicated that males and females experience similar thermal stress induced by intermittent whole-body cold immersion. Although no sex-specific differences were observed in muscle EMG activity, involuntary muscle properties, spinal and supraspinal reflexes, some of the sex differences observed (e.g., lower isometric MVC and greater cognitive perturbation in males) support the view of sex-specific physiological responses to core temperature decrease. Copyright © 2014 Elsevier Inc. All rights reserved.
Influence of chronic exposure to cold environment on thyroid gland function in rabbits.
Mustafa, S; Elgazzar, A
2014-07-01
Chronic exposure to cold can affect the thyroid gland. However, the effect on thyroid gland perfusion images and the ratio between thyroid hormones secretion were not addressed in any previous study. The present study investigates the effects of chronic cold exposure on thyroid gland function using radionuclide tracer and thyroid hormones secretion concentration. New Zealand white rabbits weighing approximately 1.8-2 kg were kept in a cold room (4°C) for 7 weeks. Thyroid scintigraphy was performed for cold exposed rabbits and a control rabbit group. Each rabbit was injected with 115 MBq (3.1 mCi) technetium-99m pertechnetate (99mTc pertechnetate). Studies were performed using Gamma camera equipped with a low energy, high resolution, pinhole collimator interfaced with a computer. Static images were acquired 20 min after administration of the radiotracer. Rabbits chronically exposed to cold had less body weights than control. Thyroid gland uptake is higher in rabbits chronically exposed to cold than controls using radionuclide perfusion study. The increase was proportional to the time period, so the increase after 7 weeks was greater than 5 weeks. There is also an increase in free triiodothyronine (FT3) and a decrease in free thyroxine (FT4) values. Our results indicate that thyroid gland uptake is higher in rabbits chronically exposed to cold than control and the increase was proportional to the duration. The decrease in rabbit body weights may be related to the increase in metabolism due to the increase of thyroid hormones. Chronic cold exposure also increased the conversion of T4 to T3, which is more potent in thermogenic effect. © Georg Thieme Verlag KG Stuttgart · New York.
Optimization of power generating thermoelectric modules utilizing LNG cold energy
NASA Astrophysics Data System (ADS)
Jeong, Eun Soo
2017-12-01
A theoretical investigation to optimize thermoelectric modules, which convert LNG cold energy into electrical power, is performed using a novel one-dimensional analytic model. In the model the optimum thermoelement length and external load resistance, which maximize the energy conversion ratio, are determined by the heat supplied to the cold heat reservoir, the hot and cold side temperatures, the thermal and electrical contact resistances and the properties of thermoelectric materials. The effects of the thermal and electrical contact resistances and the heat supplied to the cold heat reservoir on the maximum energy conversion ratio, the optimum thermoelement length and the optimum external load resistance are shown.
Dioxins from medical waste incineration: Normal operation and transient conditions.
Chen, Tong; Zhan, Ming-xiu; Yan, Mi; Fu, Jian-ying; Lu, Sheng-yong; Li, Xiao-dong; Yan, Jian-hua; Buekens, Alfons
2015-07-01
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are key pollutants in waste incineration. At present, incinerator managers and official supervisors focus only on emissions evolving during steady-state operation. Yet, these emissions may considerably be raised during periods of poor combustion, plant shutdown, and especially when starting-up from cold. Until now there were no data on transient emissions from medical (or hospital) waste incineration (MWI). However, MWI is reputed to engender higher emissions than those from municipal solid waste incineration (MSWI). The emission levels in this study recorded for shutdown and start-up, however, were significantly higher: 483 ± 184 ng Nm(-3) (1.47 ± 0.17 ng I-TEQ Nm(-3)) for shutdown and 735 ng Nm(-3) (7.73 ng I-TEQ Nm(-3)) for start-up conditions, respectively. Thus, the average (I-TEQ) concentration during shutdown is 2.6 (3.8) times higher than the average concentration during normal operation, and the average (I-TEQ) concentration during start-up is 4.0 (almost 20) times higher. So monitoring should cover the entire incineration cycle, including start-up, operation and shutdown, rather than optimised operation only. This suggestion is important for medical waste incinerators, as these facilities frequently start up and shut down, because of their small size, or of lacking waste supply. Forthcoming operation should shift towards much longer operating cycles, i.e., a single weekly start-up and shutdown. © The Author(s) 2015.
Lessons learned: design, start-up, and operation of cryogenic systems
NASA Astrophysics Data System (ADS)
Bell, W. M.; Bagley, R. E.; Motew, S.; Young, P.-W.
2014-11-01
Cryogenic systems involving a pumped cryogenic fluid, such as liquid nitrogen (LN2), require careful design since the cryogen is close to its boiling point and cold. At 1 atmosphere, LN2 boils at 77.4 K (-320.4 F). These systems, typically, are designed to transport the cryogen, use it for process heat removal, or for generation of gas (GN2) for process use. As the design progresses, it is important to consider all aspects of the design including, cryogen storage, pressure control and safety relief systems, thermodynamic conditions, equipment and instrument selection, materials, insulation, cooldown, pump start-up, maximum design and minimum flow rates, two phase flow conditions, heat flow, process control to meet and maintain operating conditions, piping integrity, piping loads on served equipment, warm-up, venting, and shut-down. "Cutting corners" in the design process can result in stalled start-ups, field rework, schedule hits, or operational restrictions. Some of these "lessoned learned" are described in this paper.
A fuel-based approach to estimating motor vehicle exhaust emissions
NASA Astrophysics Data System (ADS)
Singer, Brett Craig
Motor vehicles contribute significantly to air pollution problems; accurate motor vehicle emission inventories are therefore essential to air quality planning. Current travel-based inventory models use emission factors measured from potentially biased vehicle samples and predict fleet-average emissions which are often inconsistent with on-road measurements. This thesis presents a fuel-based inventory approach which uses emission factors derived from remote sensing or tunnel-based measurements of on-road vehicles. Vehicle activity is quantified by statewide monthly fuel sales data resolved to the air basin level. Development of the fuel-based approach includes (1) a method for estimating cold start emission factors, (2) an analysis showing that fuel-normalized emission factors are consistent over a range of positive vehicle loads and that most fuel use occurs during loaded-mode driving, (3) scaling factors relating infrared hydrocarbon measurements to total exhaust volatile organic compound (VOC) concentrations, and (4) an analysis showing that economic factors should be considered when selecting on-road sampling sites. The fuel-based approach was applied to estimate carbon monoxide (CO) emissions from warmed-up vehicles in the Los Angeles area in 1991, and CO and VOC exhaust emissions for Los Angeles in 1997. The fuel-based CO estimate for 1991 was higher by a factor of 2.3 +/- 0.5 than emissions predicted by California's MVEI 7F model. Fuel-based inventory estimates for 1997 were higher than those of California's updated MVEI 7G model by factors of 2.4 +/- 0.2 for CO and 3.5 +/- 0.6 for VOC. Fuel-based estimates indicate a 20% decrease in the mass of CO emitted, despite an 8% increase in fuel use between 1991 and 1997; official inventory models predict a 50% decrease in CO mass emissions during the same period. Cold start CO and VOC emission factors derived from parking garage measurements were lower than those predicted by the MVEI 7G model. Current inventories in California appear to understate total exhaust CO and VOC emissions, while overstating the importance of cold start emissions. The fuel-based approach yields robust, independent, and accurate estimates of on-road vehicle emissions. Fuel-based estimates should be used to validate or adjust official vehicle emission inventories before society embarks on new, more costly air pollution control programs.
Possibility of using adsorption refrigeration unit in district heating network
NASA Astrophysics Data System (ADS)
Grzebielec, Andrzej; Rusowicz, Artur; Jaworski, Maciej; Laskowski, Rafał
2015-09-01
Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50 °C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25 °C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.
Rissanen, Sirkka; Rintamäki, Hannu
2007-02-01
The objective of this study was to quantify the thermal strain of soldiers wearing nuclear, biological, and chemical protective clothing during short-term field training in cold conditions. Eleven male subjects performed marching exercises at moderate and heavy activity levels for 60 minutes. Rectal temperature (Tre), skin temperatures, and heart rate were monitored. Ambient temperature (Ta) varied from -33 to 0 degrees C. Tre was affected by changes in metabolism, rather than in Ta. Tre increased above 38 degrees during heavy exercise even at -33 degrees C. The mean skin temperature decreased to tolerance level (25 degrees C) at Ta below -25 degrees C with moderate exercise. Finger temperature decreased below 15 degrees C (performance degradation) at Ta of -15 degrees C or cooler. The present results from the field confirm the previous results based on laboratory studies and show that risk of both heat and cold strain is evident, with cooling of extremities being most critical, while wearing nuclear, biological, and chemical protective clothing during cold-weather training.
Cold machining of high density tungsten and other materials
NASA Technical Reports Server (NTRS)
Ziegelmeier, P.
1969-01-01
Cold machining process, which uses a sub-zero refrigerated cutting fluid, is used for machining refractory or reactive metals and alloys. Special carbide tools for turning and drilling these alloys further improve the cutting performance.
Numerical modeling of cold room's hinged door opening and closing processes
NASA Astrophysics Data System (ADS)
Carneiro, R.; Gaspar, P. D.; Silva, P. D.; Domingues, L. C.
2016-06-01
The need of rationalize energy consumption in agrifood industry has fasten the development of methodologies to improve the thermal and energy performances of cold rooms. This paper presents a three-dimensional (3D) transient Computational Fluid Dynamics (CFD) modelling of a cold room to evaluate the air infiltration rate through hinged doors. A species transport model is used for modelling the tracer gas concentration decay technique. Numerical predictions indicate that air temperature difference between spaces affects the air infiltration. For this case study, the infiltration rate increases 0.016 m3 s-1 per K of air temperature difference. The knowledge about the evolution of air infiltration during door opening/closing times allows to draw some conclusions about its influence on the air conditions inside the cold room, as well as to suggest best practices and simple technical improvements that can minimize air infiltration, and consequently improve thermal performance and energy consumption rationalization.
Tactile sensitivity of gloved hands in the cold operation.
Geng, Q; Kuklane, K; Holmér, I
1997-11-01
In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.
Ngas Multi-Stage Coaxial High Efficiency Cooler (hec)
NASA Astrophysics Data System (ADS)
Nguyen, T.; Toma, G.; Jaco, C.; Raab, J.
2010-04-01
This paper presents the performance data of the single and two-stage High Efficiency Cooler (HEC) tested with coaxial cold heads. The single stage coaxial cold head has been optimized to operate at temperatures of 40 K and above. The two-stage parallel cold head configuration has been optimized to operate at 30 K and above and provides a long-life, low mass and efficient two-stage version of the Northrop Grumman Aerospace Systems (NGAS) flight qualified single stage HEC cooler. The HEC pulse tube cryocoolers are the latest generation of flight coolers with heritage to the 12 Northrop Grumman Aerospace Systems (NGAS) coolers currently on orbit with 2 operating for more than 11.5 years. This paper presents the performance data of the one and two-stage versions of this cooler under a wide range of heat rejection temperature, cold head temperature and input power.
10 K high frequency pulse tube cryocooler with precooling
NASA Astrophysics Data System (ADS)
Liu, Sixue; Chen, Liubiao; Wu, Xianlin; Zhou, Yuan; Wang, Junjie
2016-07-01
A high frequency pulse tube cryocooler with precooling (HPTCP) has been developed and tested to meet the requirement of weak magnetic signals measurement, and the performance characteristics are presented in this article. The HPTCP is a two-stage pulse tube cryocooler with the precooling-stage replaced by liquid nitrogen. Two regenerators completely filled with stainless steel (SS) meshes are used in the cooler. Together with cold inertance tubes and cold gas reservoir, a cold double-inlet configuration is used to control the phase relationship of the HPTCP. The experimental result shows that the cold double-inlet configuration has improved the performance of the cooler obviously. The effects of operation parameters on the performance of the cooler are also studied. With a precooling temperature of 78.5 K, the maximum refrigeration capacity is 0.26 W at 15 K and 0.92 W at 20 K when the input electric power are 174 W and 248 W respectively, and the minimum no-load temperature obtained is 10.3 K, which is a new record on refrigeration temperature for high frequency pulse tube cryocooler reported with SS completely used as regenerative matrix.
The Packing and Jamming of Real Polymer Chains
NASA Astrophysics Data System (ADS)
Xue, Gi; Teng, Chao
2010-03-01
Jamming make a hope to unifying theme for granular materials, glasses and threshold behavior in materials. Here we experimentally prepared a real polymer (polystyrene, PS) with various packing density which was described by inter-segment distances (r) detected by NMR. We cold-pressed PS powder at 20 ^oC (with shearing) and then released the pressure. We found that a transparent pellet with high modulus was formed. PS is usually manufactured by a hot-melting process at 180 ^oC. The rigidity and transparency of our cold-pressed pellet and its accuracy of the form are testimony that the PS powder once flowed under cold compression to take the shape of its container. This shear-induced melting is exactly what is expected within the jamming picture. By measuring r and the applied pressure σ under which the polymer chain starts to flow, we drew a schematic jamming phase diagram. The σ-r curve for a real polymer is convex at r < 0.5 nm, while it becomes concave as r is larger than 1 nm. It is the van der Waals attraction that acts as a confining pressure on segments, and makes the σ-r curve convex on the very short scales.
Katzif, Samuel; Danavall, Damien; Bowers, Samera; Balthazar, Jacqueline T.; Shafer, William M.
2003-01-01
A Tn551 insertional library of Staphylococcus aureus strain ISP479 was challenged with an antimicrobial peptide (CG 117-136) derived from human neutrophil cathepsin G (CG). After repeated selection and screening of surviving colonies, a mutant was identified that expressed increased resistance to CG 117-136. Southern hybridization analysis revealed that the Tn551 insert in this mutant (SK1) was carried on a 10.6-kb EcoRI chromosomal DNA fragment. Subsequent physical mapping of this Tn551 insert revealed that it was positioned between a putative promoter sequence and the translational start codon of the cspA gene, which encodes a protein (CspA) highly similar to the major cold shock proteins CspA and CspB of Escherichia coli and Bacillus subtilis, respectively. This Tn551 insertion as well as a separate deletion-insertion mutation in cspA decreased the capacity of S. aureus to respond to the stress of cold shock and increased resistance to CG 117-136. The results indicate for the first time that a physiologic link exists between bacterial susceptibility to an antimicrobial peptide and a stress response system. PMID:12874306
Katzif, Samuel; Danavall, Damien; Bowers, Samera; Balthazar, Jacqueline T; Shafer, William M
2003-08-01
A Tn551 insertional library of Staphylococcus aureus strain ISP479 was challenged with an antimicrobial peptide (CG 117-136) derived from human neutrophil cathepsin G (CG). After repeated selection and screening of surviving colonies, a mutant was identified that expressed increased resistance to CG 117-136. Southern hybridization analysis revealed that the Tn551 insert in this mutant (SK1) was carried on a 10.6-kb EcoRI chromosomal DNA fragment. Subsequent physical mapping of this Tn551 insert revealed that it was positioned between a putative promoter sequence and the translational start codon of the cspA gene, which encodes a protein (CspA) highly similar to the major cold shock proteins CspA and CspB of Escherichia coli and Bacillus subtilis, respectively. This Tn551 insertion as well as a separate deletion-insertion mutation in cspA decreased the capacity of S. aureus to respond to the stress of cold shock and increased resistance to CG 117-136. The results indicate for the first time that a physiologic link exists between bacterial susceptibility to an antimicrobial peptide and a stress response system.
Di Rienzo, Franck; Martinent, Guillaume; Levêque, Lucie; MacIntyre, Tadhg; Collet, Christian; Guillot, Aymeric
2018-02-01
The critical importance of the start phase in bicycle motocross (BMX) racing is increasingly acknowledged. Past experiments underlined that the internal lane of the starting gate provides a strong positional advantage. However, how lane position affects start performance and cognitive and somatic state anxiety remains unexplored. We examined the start performance and anxiety responses of youth national-level BMX riders in both experimental and ecological contexts. We used contextualization motor imagery routines to evaluate start performance and state anxiety from the internal and external lanes. Cycle ergometer measures revealed a better start performance from the external lane, but we did not record any lane effect on actual gate start times. Both somatic and cognitive anxiety scores were higher before racing from the internal compared to the external lane. Finally, state anxiety (i.e., somatic anxiety, worry and concentration disruptions) negatively predicted the start performance. Present findings provide original insights on psychological factors involved in BMX start performance, and might contribute to fruitful coping interventions and training programmes in sports overlapping the framework of "handicap races" taking the specific form of positional advantages/disadvantages at the start (e.g., ski/snowboard cross, athletics, swimming, motorsports, etc.).
Yang, Qiao-Song; Wu, Jun-Hua; Li, Chun-Yu; Wei, Yue-Rong; Sheng, Ou; Hu, Chun-Hua; Kuang, Rui-Bin; Huang, Yong-Hong; Peng, Xin-Xiang; McCardle, James A; Chen, Wei; Yang, Yong; Rose, Jocelyn K C; Zhang, Sheng; Yi, Gan-Jun
2012-12-01
Banana and its close relative, plantain are globally important crops and there is considerable interest in optimizing their cultivation. Plantain has superior cold tolerance compared with banana and a thorough understanding of the molecular mechanisms and responses of plantain to cold stress has great potential value for developing cold tolerant banana cultivars. In this study, we used iTRAQ-based comparative proteomic analysis to investigate the temporal responses of plantain to cold stress. Plantain seedlings were exposed for 0, 6, and 24 h of cold stress at 8 °C and subsequently allowed to recover for 24 h at 28 °C. A total of 3477 plantain proteins were identified, of which 809 showed differential expression from the three treatments. The majority of differentially expressed proteins were predicted to be involved in oxidation-reduction, including oxylipin biosynthesis, whereas others were associated with photosynthesis, photorespiration, and several primary metabolic processes, such as carbohydrate metabolic process and fatty acid beta-oxidation. Western blot analysis and enzyme activity assays were performed on seven differentially expressed, cold-response candidate plantain proteins to validate the proteomics data. Similar analyses of the seven candidate proteins were performed in cold-sensitive banana to examine possible functional conservation, and to compare the results to equivalent responses between the two species. Consistent results were achieved by Western blot and enzyme activity assays, demonstrating that the quantitative proteomics data collected in this study are reliable. Our results suggest that an increase of antioxidant capacity through adapted ROS scavenging capability, reduced production of ROS, and decreased lipid peroxidation contribute to molecular mechanisms for the increased cold tolerance in plantain. To the best of our knowledge, this is the first report of a global investigation on molecular responses of plantain to cold stress by proteomic analysis.
Yang, Qiao-Song; Wu, Jun-Hua; Li, Chun-Yu; Wei, Yue-Rong; Sheng, Ou; Hu, Chun-Hua; Kuang, Rui-Bin; Huang, Yong-Hong; Peng, Xin-Xiang; McCardle, James A.; Chen, Wei; Yang, Yong; Rose, Jocelyn K. C.; Zhang, Sheng; Yi, Gan-Jun
2012-01-01
Banana and its close relative, plantain are globally important crops and there is considerable interest in optimizing their cultivation. Plantain has superior cold tolerance compared with banana and a thorough understanding of the molecular mechanisms and responses of plantain to cold stress has great potential value for developing cold tolerant banana cultivars. In this study, we used iTRAQ-based comparative proteomic analysis to investigate the temporal responses of plantain to cold stress. Plantain seedlings were exposed for 0, 6, and 24 h of cold stress at 8 °C and subsequently allowed to recover for 24 h at 28 °C. A total of 3477 plantain proteins were identified, of which 809 showed differential expression from the three treatments. The majority of differentially expressed proteins were predicted to be involved in oxidation-reduction, including oxylipin biosynthesis, whereas others were associated with photosynthesis, photorespiration, and several primary metabolic processes, such as carbohydrate metabolic process and fatty acid beta-oxidation. Western blot analysis and enzyme activity assays were performed on seven differentially expressed, cold-response candidate plantain proteins to validate the proteomics data. Similar analyses of the seven candidate proteins were performed in cold-sensitive banana to examine possible functional conservation, and to compare the results to equivalent responses between the two species. Consistent results were achieved by Western blot and enzyme activity assays, demonstrating that the quantitative proteomics data collected in this study are reliable. Our results suggest that an increase of antioxidant capacity through adapted ROS scavenging capability, reduced production of ROS, and decreased lipid peroxidation contribute to molecular mechanisms for the increased cold tolerance in plantain. To the best of our knowledge, this is the first report of a global investigation on molecular responses of plantain to cold stress by proteomic analysis. PMID:22982374
Traveling-Wave Tube Cold-Test Circuit Optimization Using CST MICROWAVE STUDIO
NASA Technical Reports Server (NTRS)
Chevalier, Christine T.; Kory, Carol L.; Wilson, Jeffrey D.; Wintucky, Edwin G.; Dayton, James A., Jr.
2003-01-01
The internal optimizer of CST MICROWAVE STUDIO (MWS) was used along with an application-specific Visual Basic for Applications (VBA) script to develop a method to optimize traveling-wave tube (TWT) cold-test circuit performance. The optimization procedure allows simultaneous optimization of circuit specifications including on-axis interaction impedance, bandwidth or geometric limitations. The application of Microwave Studio to TWT cold-test circuit optimization is described.
Analysis of NREL Cold-Drink Vending Machines for Energy Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deru, M.; Torcellini, P.; Bottom, K.
NREL Staff, as part of Sustainable NREL, an initiative to improve the overall energy and environmental performance of the lab, decided to control how its vending machines used energy. The cold-drink vending machines across the lab were analyzed for potential energy savings opportunities. This report gives the monitoring and the analysis of two energy conservation measures applied to the cold-drink vending machines at NREL.
New Pulsed Cold Neutron Beam Line for Fundamental Nuclear Physics at LANSCE.
Seo, P-N; Bowman, J D; Gericke, M; Gillis, R C; Greene, G L; Leuschner, M B; Long, J; Mahurin, R; Mitchell, G S; Penttila, S I; Peralta, G; Sharapov, E I; Wilburn, W S
2005-01-01
The NPDGamma collaboration has completed the construction of a pulsed cold neutron beam line on flight path12 at the Los Alamos Neutron Science Center (LANSCE). We describe the new beam line and characteristics of the beam. We report results of the moderator brightness and the guide performance measurements. FP12 has the highest pulsed cold neutron intensity for nuclear physics in the world.
Determination of the Emissivity of Materials
1962-12-31
testing. The window is protected by a magnetically-ope-ated rolling disc shutter. Bakeout heaters are provided to outgas the chamber before testing...nitrogen cold trap over a period of two hours. During this period the chamber was baked out at 350 °F. The ion-gettering pump was then started and the...If the chamber had been contaminated by previous testing, it was baked out at 350 °F during pump-down. During testing, the chamber walls were cooled to
Massive Infrared-Quiet Dense Cores: Unveiling the Initial Conditions of High-Mass Star Formation
NASA Astrophysics Data System (ADS)
Motte, F.; Bontemps, S.; Schneider, N.; Schilke, P.; Menten, K. M.
2008-05-01
As Th. Henning said at the conference, cold precursors of high-mass stars are now ``hot topics''. We here propose some observational criteria to identify massive infrared-quiet dense cores which can host the high-mass analogs of Class~0 protostars and pre-stellar condensations. We also show how far-infrared to millimeter imaging surveys of entire complexes forming OB stars are starting to unveil the initial conditions of high-mass star formation.
Massachusetts Institute of Technology Defense & Arms Control Studies Program
1996-01-01
can we offer those in government who formulate national policy? For what wars should American forces prepare? How should defense firms think about their...Haitis or was our withdrawal from Somalia the start of a trend toward isolationism? How big should the defense budget be and what should be its...and I are often asked to identify the strategy the United States should adopt now that the Cold War has become a fast fading memory. What guidance
Jaworski, Artur; Kuszewski, Hubert; Ustrzycki, Adam; Balawender, Krzysztof; Lejda, Kazimierz; Woś, Paweł
2018-04-20
Measurement of car engines exhaust pollutants emissions is very important because of their harmful effects on the environment. This article presents the assessment of repeatability of the passenger car engine exhaust pollutants emission research results obtained in the conditions of a chassis dynamometer. The research was conducted in a climate chamber, enabling the temperature conditions to be determined from - 20 to + 30 °C. The emission of CO, CH 4 , CO 2 , NO X , THC, and NMHC was subjected to the analysis. The aim of the research is to draw attention to the accuracy of the pollutant emission research results in driving cycles, and the comparison of pollutant emission results and their repeatability obtained in successive NEDC cycles under cold and hot start conditions. The results of the analysis show that, in the case of a small number of measurements, the results repeatability analysis is necessary for a proper interpretation of the pollutant emission results on the basis of the mean value. According to the authors' judgment, it is beneficial to determine the coefficient of variation for a more complete assessment of exhaust emission result repeatability obtained from a small number of measurements. This parameter is rarely presented by the authors of papers on exhaust components emission research.
In-Plume Emission Test Stand 2: emission factors for 10- to 100-kW U.S. military generators.
Zhu, Dongzi; Nussbaum, Nicholas J; Kuhns, Hampden D; Chang, M-C Oliver; Sodeman, David; Uppapalli, Sebastian; Moosmüller, Hans; Chow, Judith C; Watson, John G
2009-12-01
Although emissions of air pollutants from some military tactical equipment are not subject to the emissions standards, local communities near military bases must conform to the National Ambient Air Quality Standards. Military diesel generators are widely used in training. A portable in-plume system was used to measure fuel-based emission factors (EFs) for particulate matter (PM), carbon monoxide (CO), nitrogen oxides (NOx), and hydrocarbons (HCs) for 30-, 60-, and 100-kW generators at five load levels and for cold starts. It was found that EFs depend on multiple parameters including engine size, engine load, unit age, and total running hours. The average CO EF of generators tested was 5% lower, and the average NOx EF was 63% lower than AP-42 estimates; average PM EF was 80% less than the AP-42 estimates. A 2002 model-year 60-kW engine produced 25% less PM than a 1995 engine of the same family with similar running hours. CO EFs decrease with increasing engine load, NOx EFs increase up to mid-loads and decrease slightly at high loads, PM EFs increase with loads for 30- and 60-kW engines. CO and PM have higher EFs and NOx has a lower EF during cold starts than during hot-stabilized operation. PM chemical source profiles were also examined.
Macher, Hada C; Martinez-Broca, Maria A; Rubio-Calvo, Amalia; Leon-Garcia, Cristina; Conde-Sanchez, Manuel; Costa, Alzenira; Navarro, Elena; Guerrero, Juan M
2012-01-01
The multiple endocrine neoplasia type 2A (MEN2A) is a monogenic disorder characterized by an autosomal dominant pattern of inheritance which is characterized by high risk of medullary thyroid carcinoma in all mutation carriers. Although this disorder is classified as a rare disease, the patients affected have a low life quality and a very expensive and continuous treatment. At present, MEN2A is diagnosed by gene sequencing after birth, thus trying to start an early treatment and by reduction of morbidity and mortality. We first evaluated the presence of MEN2A mutation (C634Y) in serum of 25 patients, previously diagnosed by sequencing in peripheral blood leucocytes, using HRM genotyping analysis. In a second step, we used a COLD-PCR approach followed by HRM genotyping analysis for non-invasive prenatal diagnosis of a pregnant woman carrying a fetus with a C634Y mutation. HRM analysis revealed differences in melting curve shapes that correlated with patients diagnosed for MEN2A by gene sequencing analysis with 100% accuracy. Moreover, the pregnant woman carrying the fetus with the C634Y mutation revealed a melting curve shape in agreement with the positive controls in the COLD-PCR study. The mutation was confirmed by sequencing of the COLD-PCR amplification product. In conclusion, we have established a HRM analysis in serum samples as a new primary diagnosis method suitable for the detection of C634Y mutations in MEN2A patients. Simultaneously, we have applied the increase of sensitivity of COLD-PCR assay approach combined with HRM analysis for the non-invasive prenatal diagnosis of C634Y fetal mutations using pregnant women serum.
EVALUATION OF THE COLD PIPE PRECHARGER
The article gives results of an evaluation of the performance of the cold pipe precharger, taking a more rigorous approach than had been previously taken. The approach required detailed descriptions of electrical characteristics, electro-hydrodynamics, and charging theory. The co...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pooley, G.R.
In the aftermath of the Cold War it becomes necessary to explore the validity of nuclear deterrence as the cornerstone of the United States National Military Strategy for the upcoming period of transition in international relations. Using the current world situation as a starting point, the evolving trends in international relations, arms control and nuclear proliferation, the strategic threat and the evolution of technology will be analyzed in an effort to forecast the complexion of international relations twenty years hence. Then, within this context, nuclear deterrence and a non nuclear alternative nonoffensive defense, proposed by the Danish political scientist, Bjornmore » Moller, will be examined. In the final analysis, this project will suggest an appropriate direction for the evolution of the United States' National Military Strategy which, in the opinion of the author, provides the best probability for long term world peace.« less
Propolis: A Wonder Bees Product and Its Pharmacological Potentials
Wagh, Vijay D.
2013-01-01
Propolis is a natural resinous mixture produced by honey bees from substances collected from parts of plants, buds, and exudates. Due to its waxy nature and mechanical properties, bees use propolis in the construction and repair of their hives for sealing openings and cracks and smoothing out the internal walls and as a protective barrier against external invaders like snakes, lizards, and so forth, or against weathering threats like wind and rain. Bees gather propolis from different plants, in the temperate climate zone mainly from poplar. Current antimicrobial applications of propolis include formulations for cold syndrome (upper respiratory tract infections, common cold, and flu-like infections), wound healing, treatment of burns, acne, herpes simplex and genitalis, and neurodermatitis. Worldwide propolis has a tremendous popularity, but in India the studies over propolis have just started, not extensively reported except few regions of India like Maharashtra, West Bengal, Tamil Nadu, Gujrat, and Madhya Pradesh. PMID:24382957
Ji, Ling-Yu; Li, Xiao-Ling; Liu, Yang; Sun, Xiu-Wen; Wang, Hui-Fen; Chen, Long; Gao, Liang
2017-01-01
Background: Few studies have examined the acute exercise-induced changes in cognitive performance in different thermal environments and the time course effects. Objective: Investigate the time-dependent effects of acute exercise on university students’ processing speed, working memory and cognitive flexibility in temperate and cold environments. Method: Twenty male university students (age 23.5 ± 2.0 years) with moderate physical activity level participated in a repeated-measures within-subjects design. Processing speed, working memory and cognitive flexibility were assessed using CogState test battery at baseline (BASE), followed by a 45-min rest (REST), immediately after (EX) and 30 min after (POST-EX) 30-min moderate-intensity treadmill running in both temperate (TEMP; 25°C) and cold (COLD; 10°C) environments. Mean skin temperature (MST) and thermal sensation (TS) were also recorded. Two-way repeated measures ANOVA was performed to analyze each variable. Spearman’s rho was used to identify the correlations between MST, TS and cognitive performance. Results: Reaction time (RT) of processing speed and working memory decreased immediately after exercise in both conditions (processing speed: p = 0.003; working memory: p = 0.007). The facilitating effects on processing speed disappeared within 30 min after exercise in TEMP (p = 0.163) and COLD (p = 0.667), while improvements on working memory remained 30 min after exercise in TEMP (p = 0.047), but not in COLD (p = 0.663). Though RT of cognitive flexibility reduced in both conditions (p = 0.003), no significance was found between EX and REST (p = 0.135). Increased MST and TS were significantly associated with reductions in processing speed RT (MST: r = -0.341, p < 0.001; TS: r = -0.262, p = 0.001) and working memory RT (MST: r = -0.282, p < 0.001; TS: r = -0.2229, p = 0.005), and improvements in working memory accuracy (MST: r = 0.249, p = 0.002; TS: r = 0.255, p = 0.001). Conclusion: The results demonstrate different time-dependent effects of acute exercise on cognition in TEMP and COLD. Our study reveals facilitating effects of exercise on university students’ processing speed and working memory in both environments. However, in contrast to TEMP, effects on working memory in COLD are transient. PMID:28747896
Life Assessment of Steam Turbine Components Based on Viscoplastic Analysis
NASA Astrophysics Data System (ADS)
Choi, Woo-Sung; Fleury, Eric; Kim, Bum-Shin; Hyun, Jung-Seob
Unsteady thermal and mechanical loading in turbine components is caused due to the transient regimes arising during start-ups and shut-downs and due to changes in the operating regime in steam power plants; this results in nonuniform strain and stress distribution. Thus, an accurate knowledge of the stresses caused by various loading conditions is required to ensure the integrity and to ensure an accurate life assessment of the components of a turbine. Although the materials of the components of the steam turbine deform inelastically at a high temperature, currently, only elastic calculations are performed for safety and simplicity. Numerous models have been proposed to describe the viscoplastic (time-dependent) behavior; these models are rather elaborate and it is difficult to incorporate them into a finite element code in order to simulate the loading of complex structures. In this paper, the total lifetime of the components of a steam turbine was calculated by combining the viscoplastic constitutive equation with the ABAQUS finite element code. Viscoplastic analysis was conducted by focusing mainly on simplified constitutive equations with linear kinematic hardening, which is simple enough to be used effectively in computer simulation. The von Mises stress distribution of an HIP turbine rotor was calculated during the cold start-up operation of the rotor, and a reasonable number of cycles were obtained from the equation of Langer.
Experimental Assessment of NOx Emissions from 73 Euro 6 Diesel Passenger Cars.
Yang, Liuhanzi; Franco, Vicente; Mock, Peter; Kolke, Reinhard; Zhang, Shaojun; Wu, Ye; German, John
2015-12-15
Controlling nitrogen oxides (NOx) emissions from diesel passenger cars during real-world driving is one of the major technical challenges facing diesel auto manufacturers. Three main technologies are available for this purpose: exhaust gas recirculation (EGR), lean-burn NOx traps (LNT), and selective catalytic reduction (SCR). Seventy-three Euro 6 diesel passenger cars (8 EGR only, 40 LNT, and 25 SCR) were tested on a chassis dynamometer over both the European type-approval cycle (NEDC, cold engine start) and the more realistic Worldwide harmonized light-duty test cycle (WLTC version 2.0, hot start) between 2012 and 2015. Most vehicles met the legislative limit of 0.08 g/km of NOx over NEDC (average emission factors by technology: EGR-only 0.07 g/km, LNT 0.04 g/km, and SCR 0.05 g/km), but the average emission factors rose dramatically over WLTC (EGR-only 0.17 g/km, LNT 0.21 g/km, and SCR 0.13 g/km). Five LNT-equipped vehicles exhibited very poor performance over the WLTC, emitting 7-15 times the regulated limit. These results illustrate how diesel NOx emissions are not properly controlled under the current, NEDC-based homologation framework. The upcoming real-driving emissions (RDE) regulation, which mandates an additional on-road emissions test for EU type approvals, could be a step in the right direction to address this problem.
NASA Astrophysics Data System (ADS)
Tabe, Yutaka; Aoyama, Yusuke; Kadowaki, Kazumasa; Suzuki, Kengo; Chikahisa, Takemi
2015-08-01
In polymer electrolyte membrane fuel cells, a gas diffusion layer (GDL) with a micro-porous layer (MPL) gives better anti-flooding performance than GDLs without an MPL. To investigate the function and mechanism of the MPL to suppress water flooding, the liquid water distribution at the cathode catalyst layer (CL) surface are observed by a freezing method; in the method liquid water is immobilized in ice form by rapid freezing, followed by disassembling the cell for observations. The ice covered area is quantified by image processing and cells with and without an MPL are compared. The results show that the MPL suppresses water accumulation at the interface due to smaller pore size and finer contact with the CL, and this results in less water flooding. Investigation of ice formed after -10 °C cold start shutdowns and the temporary performance deterioration at ordinary temperatures also indicates a significant influence of the liquid water accumulating at the interface. The importance of the fine contact between CL and MPL, the relative absence of gaps, is demonstrated by a gas diffusion electrode (GDE) which is directly coated with catalyst ink on the surface of the MPL achieving finer contact of the layers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guimbal, P.; Huotilainen, S.; Taehtinen, S.
2015-07-01
As a prototype of future instrumented material experiments in the Jules Horowitz Reactor (JHR), the MELODIE project was launched in 2009 by the CEA in collaboration with VTT. Being designed as a biaxial creep experiment with online capability, MELODIE is able to apply an online-controlled biaxial loading on a LWR clad sample up to 120 MPa and to perform an online measurement of its biaxial deformation. An important experimental challenge was to perform reliably accurate measurements under the high nuclear heat load of in-core locations while keeping within their tight space. For that purpose, specific sensors were co-designed with andmore » built by IFE Halden. Manufacturing of the MELODIE components was completed one year ago. The complexity of its in-pile section and of the pressurization system requested a step-by-step tuning of the setup. The toughest part of this process dealt with the Diameter gauge which required a partial redesign to take into account unexpected and unwanted electromagnetic interactions with the hosting device. Final cold performance tests of the on-board instrumentation will be presented. The MELODIE device is now ready and irradiation should start in OSIRIS reactor this spring. (authors)« less
Main processes of the Atlantic cold tongue interannual variability
NASA Astrophysics Data System (ADS)
Planton, Yann; Voldoire, Aurore; Giordani, Hervé; Caniaux, Guy
2018-03-01
The interannual variability of the Atlantic cold tongue (ACT) is studied by means of a mixed-layer heat budget analysis. A method to classify extreme cold and warm ACT events is proposed and applied to ten various analysis and reanalysis products. This classification allows 5 cold and 5 warm ACT events to be selected over the period 1982-2007. Cold (warm) ACT events are defined by the presence of negative (positive) sea surface temperature (SST) anomalies at the center of the equatorial Atlantic in late boreal spring, preceded by negative (positive) zonal wind stress anomalies in the western equatorial Atlantic. An ocean general circulation model capable of reconstructing the interannual variability of the ACT correctly is used to demonstrate that cold ACT events develop rapidly from May to June mainly due to intense cooling by vertical mixing and horizontal advection. The simulated cooling at the center of the basin is the result of the combined effects of non-local and local processes. The non-local process is an upwelling associated with an eastward-propagating Kelvin wave, which makes the mixed-layer more shallow and preconditions the upper layers to be cooled by an intense heat loss at the base of the mixed-layer, which is amplified by a stronger local injection of energy from the atmosphere. The early cooling by vertical mixing in March is also shown to be a good predictor of June cooling. In July, horizontal advection starts to warm the mixed-layer abnormally and damps SST anomalies. The advection anomalies, which result from changes in the horizontal temperature gradient, are associated in some cases with the propagation of Rossby waves along the equator. During warm ACT events, processes are reversed, generating positive SST anomalies: a downwelling Kelvin wave triggers stratification anomalies and mixed-layer depth anomalies, amplified by a weaker injection of energy from the atmosphere in May-June. In July, warm ACT events are abnormally cooled due to negative horizontal advection anomalies resulting from processes similar to those that occur during cold ACT events. This additional cooling process extends the period of cooling of the ACT, reducing SST anomalies.
Conceptual Design and Analysis of Cold Mass Support of the CS3U Feeder for the ITER
NASA Astrophysics Data System (ADS)
Zhu, Yinfeng; Song, Yuntao; Zhang, Yuanbin; Wang, Zhongwei
2013-06-01
In the International Thermonuclear Experimental Reactor (ITER) project, the feeders are one of the most important and critical systems. To convey the power supply and the coolant for the central solenoid (CS) magnet, 6 sets of CS feeders are employed, which consist mainly of an in-cryostat feeder (ICF), a cryostat feed-through (CFT), an S-bend box (SBB), and a coil terminal box (CTB). To compensate the displacements of the internal components of the CS feeders during operation, sliding cold mass supports consisting of a sled plate, a cylindrical support, a thermal shield, and an external ring are developed. To check the strength of the developed cold mass supports of the CS3U feeder, electromagnetic analysis of the two superconducting busbars is performed by using the CATIA V5 and ANSYS codes based on parametric technology. Furthermore, the thermal-structural coupling analysis is performed based on the obtained results, except for the stress concentration, and the max. stress intensity is lower than the allowable stress of the selected material. It is found that the conceptual design of the cold mass support can satisfy the required functions under the worst case of normal working conditions. All these performed activities will provide a firm technical basis for the engineering design and development of cold mass supports.
Automobile exhaust as a means of suicide: an experimental study with a proposed model.
Morgen, C; Schramm, J; Kofoed, P; Steensberg, J; Theilade, P
1998-07-01
Experiments were conducted to investigate the concentration of carbon monoxide (CO) in a car cabin under suicide attempts with different vehicles and different start situations, and a mathematical model describing the concentration of CO in the cabin was constructed. Three cars were set up to donate the exhaust. The first vehicle didn't have any catalyst, the second one was equipped with a malfunctioning three-way catalyst, and the third car was equipped with a well-functioning three-way catalyst. The three different starting situations were cold, tepid and warm engine start, respectively. Measurements of the CO concentrations were made in both the cabin and in the exhaust pipe. Lethal concentrations were measured in the cabin using all three vehicles as the donor car, including the vehicle with the well-functioning catalyst. The model results in most cases gave a good prediction of the CO concentration in the cabin. Four case studies of cars used for suicides were described. In each case measurements of CO were made in both the cabin and the exhaust under different starting conditions, and the mathematical model was tested on these cases. In most cases the model predictions were good.
New START, Eyjafjallajökull, and Nuclear Winter
NASA Astrophysics Data System (ADS)
Robock, Alan
2010-11-01
On 8 April 2010, U.S. president Barack Obama and Russian president Dmitry Medvedev signed the Treaty Between the United States of America and the Russian Federation on Measures for the Further Reduction and Limitation of Strategic Offensive Arms, committing the United States and Russia to reducing their nuclear arsenals to levels less than 5% of the maximum during the height of the cold war in the 1980s. This treaty is called “New START,” as it is a follow-on to the 1991 Strategic Arms Reductions Treaty (START). On 14 April 2010 the Eyjafjallajökull volcano in Iceland began an explosive eruption phase that shut down air traffic in Europe for 6 days and continued to disrupt it for another month. What do these two events have in common? Nuclear weapons, when targeted at cities and industrial areas, would start fires, producing clouds of sooty smoke. Volcanic eruptions emit ash particles and sulfur dioxide (SO2), which forms sulfate aerosols in the atmosphere. Thus, both the use of nuclear weapons and volcanic eruptions produce particles that can be transported large distances from the source and can affect weather and climate.
Recommendations to Improve Employee Thermal Comfort When Working in 40°F Refrigerated Cold Rooms.
Ceballos, Diana; Mead, Kenneth; Ramsey, Jessica
2015-01-01
Cold rooms are commonly used for food storage and preparation, and are usually kept around 40°F following food safety guidelines. Some food preparation employees may spend 8 or more hours inside cold rooms. These employees may not be aware of the risks associated with mildly cold temperatures, dampness, and limited ventilation. We performed an evaluation of cold rooms at an airline catering facility because of concerns with exposure to cold temperatures. We spoke with and observed employees in two cold rooms, reviewed daily temperature logs, evaluated employee's physical activity, work/rest schedule, and protective clothing. We measured temperature, percent relative humidity, and air velocities at different work stations inside the cold rooms. We concluded that thermal comfort concerns perceived by cold room employees may have been the result of air drafts at their workstations, insufficient use of personal protective equipment due to dexterity concerns, work practices, and lack of knowledge about good health and safety practices in cold rooms. These moderately cold work conditions with low air velocities are not well covered in current occupational health and safety guidelines, and wind chill calculations do not apply. We provide practical recommendations to improve thermal comfort of cold room employees. Engineering control recommendations include the redesigning of air deflectors and installing of suspended baffles. Administrative controls include the changing out of wet clothing, providing hand warmers outside of cold rooms, and educating employees on cold stress. We also recommended providing more options on personal protective equipment. However, there is a need for guidelines and educational materials tailored to employees in moderately cold environments to improve thermal comfort and minimize health and safety problems.
Recommendations to Improve Employee Thermal Comfort When Working in 40°F Refrigerated Cold Rooms
Ceballos, Diana; Mead, Kenneth; Ramsey, Jessica
2015-01-01
Cold rooms are commonly used for food storage and preparation, and are usually kept around 40°F following food safety guidelines. Some food preparation employees may spend 8 or more hours inside cold rooms. These employees may not be aware of the risks associated with mildly cold temperatures, dampness, and limited ventilation. We performed an evaluation of cold rooms at an airline catering facility because of concerns with exposure to cold temperatures. We spoke with and observed employees in two cold rooms, reviewed daily temperature logs, evaluated employee’s physical activity, work/rest schedule, and protective clothing. We measured temperature, percent relative humidity, and air velocities at different work stations inside the cold rooms. We concluded that thermal comfort concerns perceived by cold room employees may have been the result of air drafts at their workstations, insufficient use of personal protective equipment due to dexterity concerns, work practices, and lack of knowledge about good health and safety practices in cold rooms. These moderately cold work conditions with low air velocities are not well covered in current occupational health and safety guidelines, and wind chill calculations do not apply. We provide practical recommendations to improve thermal comfort of cold room employees. Engineering control recommendations include the redesigning of air deflectors and installing of suspended baffles. Administrative controls include the changing out of wet clothing, providing hand warmers outside of cold rooms, and educating employees on cold stress. We also recommended providing more options on personal protective equipment. However, there is a need for guidelines and educational materials tailored to employees in moderately cold environments to improve thermal comfort and minimize health and safety problems. PMID:25961447
NASA Astrophysics Data System (ADS)
Devade, Kiran D.; Pise, Ashok T.
2017-01-01
Ranque Hilsch vortex tube is a device that can produce cold and hot air streams simultaneously from pressurized air. Performance of vortex tube is influenced by a number of geometrical and operational parameters. In this study parametric analysis of vortex tube is carried out. Air is used as the working fluid and geometrical parameters like length to diameter ratio (15, 16, 17, 18), exit valve angles (30°-90°), orifice diameters (5, 6 and 7 mm), 2 entry nozzles and tube divergence angle 4° is used for experimentation. Operational parameters like pressure (200-600 kPa), cold mass fraction (0-1) is varied and effect of Mach number at the inlet of the tube is investigated. The vortex tube is tested at sub sonic (0 < Ma < 1), sonic (Ma = 1) and supersonic (1 < Ma < 2) Mach number, and its effect on thermal performance is analysed. As a result it is observed that, higher COP and low cold end temperature is obtained at subsonic Ma. As CMF increases, COP rises and cold and temperature drops. Optimum performance of the tube is observed for CMF up to 0.5. Experimental correlations are proposed for optimum COP. Parametric correlation is developed for geometrical and operational parameters.
Effect of solar activity on the repetitiveness of some meteorological phenomena
NASA Astrophysics Data System (ADS)
Todorović, Nedeljko; Vujović, Dragana
2014-12-01
In this paper we research the relationship between solar activity and the weather on Earth. This research is based on the assumption that every ejection of magnetic field energy and particles from the Sun (also known as Solar wind) has direct effects on the Earth's weather. The impact of coronal holes and active regions on cold air advection (cold fronts, precipitation, and temperature decrease on the surface and higher layers) in the Belgrade region (Serbia) was analyzed. Some active regions and coronal holes appear to be in a geo-effective position nearly every 27 days, which is the duration of a solar rotation. A similar period of repetitiveness (27-29 days) of the passage of the cold front, and maximum and minimum temperatures measured at surface and at levels of 850 and 500 hPa were detected. We found that 10-12 days after Solar wind velocity starts significantly increasing, we could expect the passage of a cold front. After eight days, the maximum temperatures in the Belgrade region are measured, and it was found that their minimum values appear after 12-16 days. The maximum amount of precipitation occurs 14 days after Solar wind is observed. A recurring period of nearly 27 days of different phases of development for hurricanes Katrina, Rita and Wilma was found. This analysis confirmed that the intervals of time between two occurrences of some particular meteorological parameter correlate well with Solar wind and A index.
Valdenegro, Mónika; Huidobro, Camila; Monsalve, Liliam; Bernales, Maricarmen; Fuentes, Lida; Simpson, Ricardo
2018-03-24
Pomegranate (Punica granatum) is a non-climacteric fruit susceptible to chilling injury (CI) at temperatures below 5 °C. To understand the influences of ethylene and modified atmosphere on CI physiological disorders of pomegranate, exogenous ethrel (0.5, 1 and 1.5 µg L -1 ) treatments, 1-methylcyclopropene (1-MCP) (1 µL L -1 ) exposure, packaging in a modified atmosphere (MAP) (XTend™ bags; StePac, São Paulo, Brazil), a MAP/1-MCP combination, and packaging in macro-perforated bags (MPB) were applied. The treated fruits were cold stored (2 ± 1 °C; 85% relative humidity) and sampled during 120 + 3 days at 20 °C. During cold storage, CI symptoms started at 20 days in MPB and at 60 days for all exogenous ethylene treatments, and were delayed to 120 days in MAP, 1-MCP and MAP/1-MCP treatments. MPB and ethylene treatments induced significant electrolyte leakage, oxidative damage, lipid peroxidation, ethylene and CO 2 production, and 1-aminocyclopropane-1-carboxylic acid oxidase activity, without any change in total soluble solids, titratable acidity or skin and aril colours. Conversely, MAP by itself, or in combination with 1-MCP application, effectively delayed CI symptoms. During long-term cold storage of this non-climacteric fruit, ethrel application induced endogenous ethylene biosynthesis, accelerating the appearance of CI symptoms in contrast to the observations made for MAP and 1-MCP treatments. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Arjamaa, O; Mäkinen, T; Turunen, L; Huttunen, P; Leppäluoto, J; Vuolteenaho, O; Rintamäki, H
2001-05-01
The objective of the study was to compare blood pressure and endocrine responses in a cold pressure test in young healthy subjects who had shown increased blood pressure during an acutely increased sodium intake. Subjects (n = 53) added 121 mmol sodium into their normal diet for one week. If the mean arterial pressure had increased by a minimum of 5 mmHg compared to the control measure, they were selected for the experiments. The selected subjects (n = 8) were given 121 mmol supplemental sodium d-1 for 14 days after which they immersed the right hand into a cold (+10 degrees C) water bath for 5 min. The blood pressure increased (P < 0.05) during the test and was independent of the sodium intake. The plasma noradrenaline increased from 2.41 +/- 0.38 nmol l-1 to 2.82 +/- 0.42 nmol l-1 (P < 0.05) with normal diet and from 1.85 +/- 0.29 nmol l-1 to 2.40 +/- 0.37 nmol l-1 (P < 0.05) with high sodium diet. The starting concentrations and the endpoint concentrations were statistically similar. The plasma levels of natriuretic peptides (NT-proANP, ANP and BNP) did not change during the test, and the concentrations were independent of the sodium diet. To conclude, acutely increased sodium intake does not change blood pressure or hormonal responses in a cold pressor test in young healthy subjects.
Cenik, Can; Cenik, Elif Sarinay; Byeon, Gun W; Grubert, Fabian; Candille, Sophie I; Spacek, Damek; Alsallakh, Bilal; Tilgner, Hagen; Araya, Carlos L; Tang, Hua; Ricci, Emiliano; Snyder, Michael P
2015-11-01
Elucidating the consequences of genetic differences between humans is essential for understanding phenotypic diversity and personalized medicine. Although variation in RNA levels, transcription factor binding, and chromatin have been explored, little is known about global variation in translation and its genetic determinants. We used ribosome profiling, RNA sequencing, and mass spectrometry to perform an integrated analysis in lymphoblastoid cell lines from a diverse group of individuals. We find significant differences in RNA, translation, and protein levels suggesting diverse mechanisms of personalized gene expression control. Combined analysis of RNA expression and ribosome occupancy improves the identification of individual protein level differences. Finally, we identify genetic differences that specifically modulate ribosome occupancy--many of these differences lie close to start codons and upstream ORFs. Our results reveal a new level of gene expression variation among humans and indicate that genetic variants can cause changes in protein levels through effects on translation. © 2015 Cenik et al.; Published by Cold Spring Harbor Laboratory Press.
Local Area Water Removal Analysis of a Proton Exchange Membrane Fuel Cell under Gas Purge Conditions
Lee, Chi-Yuan; Lee, Yu-Ming; Lee, Shuo-Jen
2012-01-01
In this study, local area water content distribution under various gas purging conditions are experimentally analyzed for the first time. The local high frequency resistance (HFR) is measured using novel micro sensors. The results reveal that the liquid water removal rate in a membrane electrode assembly (MEA) is non-uniform. In the under-the-channel area, the removal of liquid water is governed by both convective and diffusive flux of the through-plane drying. Thus, almost all of the liquid water is removed within 30 s of purging with gas. However, liquid water that is stored in the under-the-rib area is not easy to remove during 1 min of gas purging. Therefore, the re-hydration of the membrane by internal diffusive flux is faster than that in the under-the-channel area. Consequently, local fuel starvation and membrane degradation can degrade the performance of a fuel cell that is started from cold. PMID:22368495
Yamadera, Yukio; Aihara, Rieko; Koitabashi, Yoshie; Matsuda, Mitsuko; Takakuda, Yoshie; Kurosaki, Sachiko
2014-08-01
Children are often frightened, cry, refuse to sit still, and may not cooperate during a physiological examination. Technologists must take considerable care to reduce the child's anxiety. Specifically, we should use creative solutions, start by interacting with the patient, using dolls or toys, and explain the procedure to him/her in a friendly way, communicating more effectively with the patient's family. When performing the actual examinations, technologists need to work skillfully with a complete understanding of the purpose of the examinations, having the ability to identify the changes that occur in various developmental stages and interpret the pathophysiological mechanisms specific to children. Furthermore, we must always have an awareness of safety, taking measures to prevent falls from the bed and/or to keep the room warm if examinations require the child to be naked, so that he/she will not catch a cold. I explain various points of caution and possible solutions regarding electrocardiograms, electroencephalograms, and ultrasonography, from the viewpoint of a medical technologist.
NASA Astrophysics Data System (ADS)
Palumbo, G.; Piccininni, A.; Guglielmi, P.; Sorgente, D.; Tricarico, L.
2016-08-01
The present work deals with the advantages in the Hydromechanical Deep Drawing (HDD) when AA5754 Tailored Heat Treated Blanks (THTBs) are adopted. It is well known that the creation of a suitable distribution of material properties increases the process performance. When non heat-treatable alloys are considered, the THTB approach can be successfully applied to increase the Limit Drawing Ratio (LDR) by changing the peripheral zone into the annealed state starting from a cold-worked blank. If this approach is combined with the advantages of a counterpressure, even more remarkable improvements can be achieved. Due to the large number of involved parameters, the optimized design of both the local treatment and the pressure profile were investigated coupling an axial symmetric Finite Element model with the integration platform modeFRONTIER. Results confirmed the possibility of increasing the LDR from 2.0 (Deep Drawing using a blank in the annealed state) up to about 3.0 if combining the adoption of a THTB with the optimal pressure profile.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greene, David L; Duleep, Gopal
2013-06-01
Automobile manufacturers leading the development of mass-market fuel cell vehicles (FCVs) were interviewed in Japan, Korea, Germany and the United States. There is general agreement that the performance of FCVs with respect to durability, cold start, packaging, acceleration, refueling time and range has progressed to the point where vehicles that could be brought to market in 2015 will satisfy customer expectations. However, cost and the lack of refueling infrastructure remain significant barriers. Costs have been dramatically reduced over the past decade, yet are still about twice what appears to be needed for sustainable market success. While all four countries havemore » plans for the early deployment of hydrogen refueling infrastructure, the roles of government, industry and the public in creating a viable hydrogen refueling infrastructure remain unresolved. The existence of an adequate refueling infrastructure and supporting government policies are likely to be the critical factors that determine when and where hydrogen FCVs are brought to market.« less
Recommendation based on trust diffusion model.
Yuan, Jinfeng; Li, Li
2014-01-01
Recommender system is emerging as a powerful and popular tool for online information relevant to a given user. The traditional recommendation system suffers from the cold start problem and the data sparsity problem. Many methods have been proposed to solve these problems, but few can achieve satisfactory efficiency. In this paper, we present a method which combines the trust diffusion (DiffTrust) algorithm and the probabilistic matrix factorization (PMF). DiffTrust is first used to study the possible diffusions of trust between various users. It is able to make use of the implicit relationship of the trust network, thus alleviating the data sparsity problem. The probabilistic matrix factorization (PMF) is then employed to combine the users' tastes with their trusted friends' interests. We evaluate the algorithm on Flixster, Moviedata, and Epinions datasets, respectively. The experimental results show that the recommendation based on our proposed DiffTrust + PMF model achieves high performance in terms of the root mean square error (RMSE), Recall, and F Measure.
Recommendation Based on Trust Diffusion Model
Li, Li
2014-01-01
Recommender system is emerging as a powerful and popular tool for online information relevant to a given user. The traditional recommendation system suffers from the cold start problem and the data sparsity problem. Many methods have been proposed to solve these problems, but few can achieve satisfactory efficiency. In this paper, we present a method which combines the trust diffusion (DiffTrust) algorithm and the probabilistic matrix factorization (PMF). DiffTrust is first used to study the possible diffusions of trust between various users. It is able to make use of the implicit relationship of the trust network, thus alleviating the data sparsity problem. The probabilistic matrix factorization (PMF) is then employed to combine the users' tastes with their trusted friends' interests. We evaluate the algorithm on Flixster, Moviedata, and Epinions datasets, respectively. The experimental results show that the recommendation based on our proposed DiffTrust + PMF model achieves high performance in terms of the root mean square error (RMSE), Recall, and F Measure. PMID:25009827
Personalized recommendation based on heat bidirectional transfer
NASA Astrophysics Data System (ADS)
Ma, Wenping; Feng, Xiang; Wang, Shanfeng; Gong, Maoguo
2016-02-01
Personalized recommendation has become an increasing popular research topic, which aims to find future likes and interests based on users' past preferences. Traditional recommendation algorithms pay more attention to forecast accuracy by calculating first-order relevance, while ignore the importance of diversity and novelty that provide comfortable experiences for customers. There are some levels of contradictions between these three metrics, so an algorithm based on bidirectional transfer is proposed in this paper to solve this dilemma. In this paper, we agree that an object that is associated with history records or has been purchased by similar users should be introduced to the specified user and recommendation approach based on heat bidirectional transfer is proposed. Compared with the state-of-the-art approaches based on bipartite network, experiments on two benchmark data sets, Movielens and Netflix, demonstrate that our algorithm has better performance on accuracy, diversity and novelty. Moreover, this method does better in exploiting long-tail commodities and cold-start problem.
Lee, Chi-Yuan; Lee, Yu-Ming; Lee, Shuo-Jen
2012-01-01
In this study, local area water content distribution under various gas purging conditions are experimentally analyzed for the first time. The local high frequency resistance (HFR) is measured using novel micro sensors. The results reveal that the liquid water removal rate in a membrane electrode assembly (MEA) is non-uniform. In the under-the-channel area, the removal of liquid water is governed by both convective and diffusive flux of the through-plane drying. Thus, almost all of the liquid water is removed within 30 s of purging with gas. However, liquid water that is stored in the under-the-rib area is not easy to remove during 1 min of gas purging. Therefore, the re-hydration of the membrane by internal diffusive flux is faster than that in the under-the-channel area. Consequently, local fuel starvation and membrane degradation can degrade the performance of a fuel cell that is started from cold.
Analysis of Fatigue Crack Paths in Cold Drawn Pearlitic Steel
Toribio, Jesús; González, Beatriz; Matos, Juan-Carlos
2015-01-01
In this paper, a fracto-metallographic analysis was performed on the cracked specimens of cold drawn pearlitic steel subjected to fatigue tests. Fatigue cracks are transcollonial and exhibit a preference for fracturing pearlitic lamellae, with non-uniform crack opening displacement values, micro-discontinuities, branchings, bifurcations and frequent local deflections that create microstructural roughness. At the micro-level, the cold drawn pearlitic steel exhibits higher micro-roughness than the hot rolled bar (this is a consequence of the manufacturing process by cold drawing), so that the actual fractured surface in the cold drawn wire is greater than that in the hot rolled bar, due to the fact that the crack deflection events are more frequent and with higher angle in the former (the heavily drawn prestressing steel wire). These findings show the relevant role on the manufacturing process by cold drawing in the fatigue crack propagation in pearlitic steel. PMID:28793647
Analysis of Fatigue Crack Paths in Cold Drawn Pearlitic Steel.
Toribio, Jesús; González, Beatriz; Matos, Juan-Carlos
2015-11-04
In this paper, a fracto-metallographic analysis was performed on the cracked specimens of cold drawn pearlitic steel subjected to fatigue tests. Fatigue cracks are transcollonial and exhibit a preference for fracturing pearlitic lamellae, with non-uniform crack opening displacement values, micro-discontinuities, branchings, bifurcations and frequent local deflections that create microstructural roughness. At the micro-level, the cold drawn pearlitic steel exhibits higher micro-roughness than the hot rolled bar (this is a consequence of the manufacturing process by cold drawing), so that the actual fractured surface in the cold drawn wire is greater than that in the hot rolled bar, due to the fact that the crack deflection events are more frequent and with higher angle in the former (the heavily drawn prestressing steel wire). These findings show the relevant role on the manufacturing process by cold drawing in the fatigue crack propagation in pearlitic steel.
Cai, Wansong; Chen, Zhiyuan; Wen, Liping; Jiang, Xiangxin; Liu, Xiuheng
2016-01-01
Evaluate the efficiency and safety of bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes for the treatment of posterior urethral stricture. Compare the outcomes following bipolar plasma vaporization with conventional cold-knife urethrotomy. A randomized trial was performed to compare patient outcomes from the bipolar and cold-knife groups. All patients were assessed at 6 and 12 months postoperatively via urethrography and uroflowmetry. At the end of the first postoperative year, ureteroscopy was performed to evaluate the efficacy of the procedure. The mean follow-up time was 13.9 months (range: 12 to 21 months). If re-stenosis was not identified by both urethrography and ureteroscopy, the procedure was considered "successful". Fifty-three male patients with posterior urethral strictures were selected and randomly divided into two groups: bipolar group (n=27) or cold-knife group (n=26). Patients in the bipolar group experienced a shorter operative time compared to the cold-knife group (23.45±7.64 hours vs 33.45±5.45 hours, respectively). The 12-month postoperative Qmax was faster in the bipolar group than in the cold-knife group (15.54±2.78 ml/sec vs 18.25±2.12 ml/sec, respectively). In the bipolar group, the recurrence-free rate was 81.5% at a mean follow-up time of 13.9 months. In the cold-knife group, the recurrence-free rate was 53.8%. The application of bipolar plasma-cutting and plasma-loop electrodes for the management of urethral stricture disease is a safe and reliable method that minimizes the morbidity of urethral stricture resection. The advantages include a lower recurrence rate and shorter operative time compared to the cold-knife technique.
Berg, Regan J; Inaba, Kenji; Sullivan, Maura; Okoye, Obi; Siboni, Stefano; Minneti, Michael; Teixeira, Pedro G; Demetriades, Demetrios
2015-01-01
Increasing ambient temperature to prevent intraoperative patient hypothermia remains widely advocated despite unconvincing evidence of efficacy. Heat stress is associated with decreased cognitive and psychomotor performance across multiple tasks but remains unexamined in an operative context. We assessed the impact of increased ambient temperature on laparoscopic operative performance and surgeon cognitive stress. Forty-two performance measures were obtained from 21 surgery trainees participating in the counter-balanced, within-subjects study protocol. Operative performance was evaluated with adaptations of the validated, peg-transfer, and intracorporeal knot-tying tasks from the Fundamentals of Laparoscopic Surgery program. Participants trained to proficiency before enrollment. Task performance was measured at two ambient temperatures, 19 and 26°C (66 and 79°F). Participants were randomly counterbalanced to initial hot or cold exposure before crossing over to the alternate environment. Cognitive stress was measured using the validated Surgical Task Load Index (SURG-TLX). No differences in performance of the peg-transfer and intracorporeal knot-tying tasks were seen across ambient conditions. Assessed via use of the six bipolar scales of the SURG-TLX, we found differences in task workload between the hot and cold conditions in the areas of physical demands (hot 10 [3-12], cold 5 [2.5-9], P = .013) and distractions (hot 8 [3.5-15.5], cold 3 [1.5-5.5], P = .001). Participant perception of distraction remained greater in the hot condition on full scoring of the SURG-TLX. Increasing ambient temperature to levels advocated for prevention of intraoperative hypothermia does not greatly decrease technical performance in short operative tasks. Surgeons, however, do report increased perceptions of distraction and physical demand. The impact of these findings on performance and outcomes during longer operative procedures remains unclear. Copyright © 2015 Elsevier Inc. All rights reserved.
Uncertainty Analysis of Historical Hurricane Data
NASA Technical Reports Server (NTRS)
Green, Lawrence L.
2007-01-01
An analysis of variance (ANOVA) study was conducted for historical hurricane data dating back to 1851 that was obtained from the U. S. Department of Commerce National Oceanic and Atmospheric Administration (NOAA). The data set was chosen because it is a large, publicly available collection of information, exhibiting great variability which has made the forecasting of future states, from current and previous states, difficult. The availability of substantial, high-fidelity validation data, however, made for an excellent uncertainty assessment study. Several factors (independent variables) were identified from the data set, which could potentially influence the track and intensity of the storms. The values of these factors, along with the values of responses of interest (dependent variables) were extracted from the data base, and provided to a commercial software package for processing via the ANOVA technique. The primary goal of the study was to document the ANOVA modeling uncertainty and predictive errors in making predictions about hurricane location and intensity 24 to 120 hours beyond known conditions, as reported by the data set. A secondary goal was to expose the ANOVA technique to a broader community within NASA. The independent factors considered to have an influence on the hurricane track included the current and starting longitudes and latitudes (measured in degrees), and current and starting maximum sustained wind speeds (measured in knots), and the storm starting date, its current duration from its first appearance, and the current year fraction of each reading, all measured in years. The year fraction and starting date were included in order to attempt to account for long duration cyclic behaviors, such as seasonal weather patterns, and years in which the sea or atmosphere were unusually warm or cold. The effect of short duration weather patterns and ocean conditions could not be examined with the current data set. The responses analyzed were the storm latitude, longitude and intensity, as recorded in the data set, 24 or 120 hours beyond the current state. Several ANOVA modeling schemes were examined. Two forms of validation were used: 1) comparison with official hurricane prediction performance metrics and 2) cases studies conducted on hurricanes from the 2005 season, which were not included within the model construction and ANOVA assessment. In general, the ANOVA technique did not perform as well as the established official prediction performance metrics published by NOAA; still, the technique did remarkably well in this demonstration with a difficult data set and could probably be made to perform better with more knowledge of hurricane development and dynamics applied to the problem. The technique provides a repeatable prediction process that eliminates the need for judgment in the forecast.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Hai-Tao, E-mail: liuht@ral.neu.edu.cn; Institute of Research of Iron and Steel, Shasteel, Zhangjiagang 215625, Jiangsu; Yao, Sheng-Jie
2015-08-15
In the present work, a regular grade GO sheet was produced successively by strip casting, hot rolling, normalizing annealing, two-stage cold rolling with intermediate annealing, primary recrystallization annealing, secondary recrystallization annealing and purification. The aim of this paper was to characterize the evolution of microstructure, texture and inhibitor along the new processing route by comprehensive utilization of optical microscopy, X-ray diffraction and transmission electron microscopy. It was found that a fine microstructure with the ferrite grain size range of 7–12 μm could be obtained in the primary recrystallization annealed sheet though a very coarse microstructure was produced in the initialmore » as-cast strip. The main finding was that the “texture memory” effect on Goss texture started on the through-thickness intermediate annealed strip after first cold rolling, which was not similar to the “texture memory” effect on Goss texture starting on the surface layers of the hot rolled strip in the conventional production route. As a result, the origin of Goss nuclei capable of secondary recrystallization lied in the grains already presented in Goss orientation in the intermediate annealed strip after first cold rolling. Another finding was that fine and dispersive inhibitors (mainly AlN) were easy to be produced in the primary recrystallization microstructure due to the initial rapid solidification during strip casting and the subsequent rapid cooling, and the very high temperature reheating usually used before hot rolling in the conventional production route could be avoided. - Highlights: • A regular grade grain-oriented electrical steel was produced. • Evolution of microstructure, texture and inhibitor was characterized. • Origin of Goss nuclei lied in the intermediate annealed strip. • A fine primary recrystallization microstructure could be produced. • Effective inhibitors were easy to be obtained in the new processing route.« less
Bustamante, Claudia A.; Monti, Laura L.; Gabilondo, Julieta; Scossa, Federico; Valentini, Gabriel; Budde, Claudio O.; Lara, María V.; Fernie, Alisdair R.; Drincovich, María F.
2016-01-01
Reconfiguration of the metabolome is a key component involved in the acclimation to cold in plants; however, few studies have been devoted to the analysis of the overall metabolite changes after cold storage of fruits prior to consumption. Here, metabolite profiling of six peach varieties with differential susceptibility to develop mealiness, a chilling-injury (CI) symptom, was performed. According to metabolic content at harvest; after cold treatment; and after ripening, either following cold treatment or not; peach fruits clustered in distinct groups, depending on harvest-time, cold treatment, and ripening state. Both common and distinct metabolic responses among the six varieties were found; common changes including dramatic galactinol and raffinose rise; GABA, Asp, and Phe increase; and 2-oxo-glutarate and succinate decrease. Raffinose content after long cold treatment quantitatively correlated to the degree of mealiness resistance of the different peach varieties; and thus, raffinose emerges as a candidate biomarker of this CI disorder. Xylose increase after cold treatment was found only in the susceptible genotypes, indicating a particular cell wall reconfiguration of these varieties while being cold-stored. Overall, results indicate that peach fruit differential metabolic rearrangements due to cold treatment, rather than differential metabolic priming before cold, are better related with CI resistance. The plasticity of peach fruit metabolism renders it possible to induce a diverse metabolite array after cold, which is successful, in some genotypes, to avoid CI. PMID:27746802
Evaluation of Polymer Hermetically Sealed Tantalum Capacitors
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander A.
2014-01-01
Polymer cathode tantalum capacitors have lower ESR (equivalent series resistance) compared to other types of tantalum capacitors and for this reason have gained popularity in the electronics design community. Their use allows improved performance of power supply systems along with substantial reduction of size and weight of the components used. However, these parts have poor thermal stability and can degrade in humid environments. Polymer hermetically sealed (PHS) capacitors avoid problems related to environmental degradation of molded case parts and can potentially replace current wet and solid hermetically sealed capacitors. In this work, PHS capacitors manufactured per DLA LAM DWG#13030 are evaluated for space applications. Several lots of capacitors manufactured over period from 2010 to 2014 were tested for the consistency of performance, electrical and thermal characteristics, highly accelerated life testing, and robustness under reverse bias and random vibration conditions. Special attention was given to analysis of leakage currents and the effect of long-term high temperature storage on capacitors in as is condition and after hermeticity loss. The results show that PHS capacitors might be especially effective for low-temperature applications or for system requiring a cold start-up. Additional screening and qualification testing have been recommended to assure the necessary quality of capacitors for space projects.
Efficacy of a heat exchanger mask in cold exercise-induced asthma.
Beuther, David A; Martin, Richard J
2006-05-01
To determine the efficacy of a novel mask device in limiting cold air exercise-induced decline in lung function in subjects with a history of exercise-induced asthma (EIA). In spite of appropriate medical therapy, many asthma patients are limited in cold weather activities. In study 1, 13 asthmatic subjects performed two randomized, single-blind treadmill exercise tests while breathing cold air (- 25 to - 15 degrees C) through a placebo or active heat exchanger mask. In study 2, five subjects with EIA performed three treadmill exercise tests while breathing cold air: one test using the heat exchanger mask, one test without the mask but with albuterol pretreatment, and one test with neither the mask nor albuterol pretreatment (unprotected exercise). For all studies, spirometry was performed before and at 5, 15, and 30 min after exercise challenge. For both studies, a total of 15 subjects with a history of asthma symptoms during cold air exercise were recruited. In study 1, the mean decrease (+/- SE) in FEV1 was 19 +/- 4.9% with placebo, and 4.3 +/- 1.6% with the active device (p = 0.0002). The mean decrease in maximum mid-expiratory flow (FEF(25-75)) was 31 +/- 5.7% with placebo and 4.7 +/- 1.7% with the active device (p = 0.0002). In study 2, the mean decrease in FEV1 was 6.3 +/- 3.9%, 11 +/- 3.7%, and 28 +/- 10% for the heat exchanger mask, albuterol pretreatment, and unprotected exercises, respectively (p = 0.4375 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). The mean decrease in FEF(25-75) was 10 +/- 4.8%, 23 +/- 6.0%, and 36 +/- 11%, respectively (p = 0.0625 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). This heat exchanger mask blocks cold exercise-induced decline in lung function at least as effectively as albuterol pretreatment.
Effects of hot and cold temperature exposure on performance : a meta-analytic review
DOT National Transportation Integrated Search
2002-01-01
Adjusting to and working under hot or cold temperatures has long been a challenge for people living under immoderate weather conditions. In spite of the ability in industrialized societies to control indoor temperatures, a similar challenge continues...
Evaluation of a Schatz heat battery on a flexible-fueled vehicle
NASA Astrophysics Data System (ADS)
Piotrowski, Gregory K.; Schaefer, Ronald M.
1991-09-01
The evaluation is described of a Schatz Heat Battery as a means of reducing cold start emissions from a motor vehicle fueled with both gasoline and M85 high methanol blend fuel. The evaluation was conducted at both 20 and 75 F ambient temperatures. The test vehicle was a flexible fueled 1990 Audi 80 supplied by Volkswagen of America. A description is included of the test vehicle, the test facilities, the analytical methods and test procedures used.
Evaluation of a Schatz heat battery on a flexible-fueled vehicle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piotrowski, G.K.; Schaefer, R.M.
The report describes the evaluation of a Schatz Heat Battery as a means of reducing cold start emissions from a motor vehicle fueled with both gasoline and M85 high methanol blend fuel. The evaluation was conducted at both 20 F and 75 F ambient temperatures. The test vehicle was a flexible-fueled 1990 Audi 80 supplied by Volkswagen of America. The report also includes a description of the test vehicle, the test facilities, the analytical methods and test procedures used.
Evaluation of Commercially Available Cold Chain Shipping Systems
2015-03-19
instructions for the maceration of heart tissue. Briefly, 10 g of ground beef was placed alone or with 40 mL 4°C phosphate buffered saline (PBS) in...room temperature (25°C) raw ground beef was placed in a 50-mL IKA Turrax tube with rotor-stator elements and 40 mL of 4°C PBS. Temperature probes...were placed in the center of the ground beef to record the starting temperature and removed during the homogenization process. Turrax homogenization
The Evolution of the Sonobuoy from World War II to the Cold War
2014-01-01
airship , the first aircraft intentionally built for ASW.2 After Wilbur and Orville Wright’s first successful airplane flight in December 1903, the...aircraft had to shut down its engines to use the hydrophone, there was reluctance to use this method for fear the aircraft engine would not start again...the sonobuoy would act as the receiver for the echo from the submarine. This mode became known as “Julie” in 1955, when engineers who worked on the
2010-06-01
theory, by creating an offensive oriented 10 Tariq M. Ashraf , “Doctrinal Reawakening of the Indian...5Cpapers23%5Cpaper2293.html (accessed July 19, 2009). 19 Ashraf , “Doctrinal Reawakening,” 58. 10 nuclear threshold emerges as one of the major constraints...20 Ashraf , “Doctrinal Reawakening,” 59. 21 Ikram Sehgal, “War-Gaming Nuclear Armageddon,” The News, 29 January 2009
2016-06-01
analysts fielded questions about whether the crisis in Ukraine was the start of a new Cold War. The American public’s surprise and confusion...Foreign Policy, CNN, Time Magazine, The Economist, The Wall Street Journal, The New Yorker, The Atlantic, and more. National security analysts fielded...Bezopasnosti (Committee for State Security or KGB) agent who rose from political obscurity, Putin’s past can be difficult to research . However, there are
Deterrence Adrift Mapping Conflict and Escalation in South Asia
2016-06-21
Response, published in December 2011. ✵ ✵ ✵ ✵ ✵ Ryan W. French is a researcher and operations specialist for the Naval War College’s Strategic Re- search...relation- ship, India ordered Pakistan International Airlines to shutter its offices in New Delhi.4 As 2015 progressed, the acrimony showed little sign of...extant literature by map- ping the military operational imperatives New Delhi and Islamabad might face in a Cold Start contingency and by analyzing the
1991-07-17
prominent and prestigious fora. Perhaps Japan’s leading exponent of the realist school is Seizaburo Sato , professor at Tokyo University, research director...involves Sato’s frank recognition of "how important military strength is to protect peace at this starting point of the post-cold war period.൩ Sato ...in an increasingly interdependent world.34 To Sato , noncoercive forms of power supplement traditional military might but they emphatically do not
Hot heads and cold brains. Aristotle, Galen and the "radiator theory".
Longo, O
1996-01-01
The Author examines two similar theories about the functioning of human brain as a refrigerator: Falk's and Fialkowski's (1990) and Aristotle's (IVth century b.C.). There are surprising, although fortuitous, convergences between the two, with the remarkable difference, however, that Artistotle's doctrine (later severely criticized by Galen) thinks of the brain merely as an organ for the cooling of the body's (the heart's) heat, while according to the modern radiator theory the human brain developed starting as a refrigerator of itself.
Does water temperature influence the performance of key survival skills?
Schnitzler, C; Button, C; Seifert, L; Armbrust, G; Croft, J L
2018-03-01
Aquatic survival skills may be compromised in cold water thereby increasing the likelihood of drowning. This study compared physiological, psychological, and behavioral responses of humans treading water and swimming in cold and temperate water. Thirty-eight participants were classified as inexperienced (n = 9), recreational (n = 15), or skilled (n = 10) swimmers. They performed 3 tasks: treading water (120 seconds), swim at "comfortable" pace, and swim at "fast" pace in 2 water conditions (28°C vs 10°C). Heart rate, oxygen uptake, psychometric variables, spatio-temporal (swim speed, stroke rate, and stroke length), and coordination type were examined as a function of expertise. Tasks performed in cold water-generated higher cardiorespiratory responses (HR = 145 ± 16 vs 127 ± 21 bpm) and were perceived about 2 points more strenuous on the Borg scale on average (RPE = 14.9 ± 2.8 vs 13.0 ± 2.0). The voluntary durations of both treading water (60 ± 32 vs 91 ± 33 seconds) and swimming at a comfortable pace (66 ± 22 vs 103 ± 34 seconds) were significantly reduced in cold water. However, no systematic changes in movement pattern type could be determined in either the treading water task or the swimming tasks. Water temperature influences the physical demands of these aquatic skills but not necessarily the behavior. Training treading water and swimming skills in temperate water seems to transfer to cold water, but we recommend training these skills in a range of water conditions to help adapt to the initial "cold-shock" response. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cold-air performance of a tip turbine designed to drive a lift fan. 1: Baseline performance
NASA Technical Reports Server (NTRS)
Haas, J. E.; Kofskey, M. G.; Hotz, G. M.; Futral, S. M., Jr.
1976-01-01
Full admission baseline performance was obtained for a 0.4 linear scale of the LF460 lift fan turbine over a range of speeds and pressure ratios without leakage air. These cold-air tests covered a range of speeds from 40 to 140 percent of design equivalent speed and a range of scroll inlet to diffuser exit static pressure ratios from 2.0 to 4.2. Results are presented in terms of specific work, torque, mass flow, efficiency, and total pressure drop.
Hayter, Kane J.; Schumann, Moritz; Deakin, Glen B.
2016-01-01
This study examined the effects of cold-water immersion (CWI) and cold air therapy (CAT) on maximal cycling performance (i.e. anaerobic power) and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10) and female (n = 10) participants were randomised into either: CWI (15 min in 14 °C water to iliac crest) or CAT (15 min in 14 °C air) immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively). Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24), 48 (T48) and 72 (T72) h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05). However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90), T48 (8% ± 2%, ES = 0.64) and T72 (8% ± 7%, ES = 0.76). The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone. PMID:27069791
Effect of Cold-rolling on Mechanical Properties and Microstructure of an Al-12%Si-0.2%Mg Alloy
NASA Astrophysics Data System (ADS)
Liao, Hengcheng; Cai, Mingdong; Jing, Qiumin; Ding, Ke
2011-11-01
Effect of multi-pass cold-rolling on the mechanical properties and microstructure of a near-eutectic Al-12%Si-0.2%Mg casting alloy was investigated. Optical microscopy, SEM, and TEM were employed to resolve the as-rolled microstructure, and the microstructure of samples after aging treatment. It has been found that Brinell hardness increases considerably with rolling reduction ratio; and further annealing leads to a remarkable drop in hardness. Two mechanisms, namely precipitation hardening and recovery softening, were found to develop simultaneously in the subsequent aging treatment following cold rolling. In contrast, recovery softening dominated the aging of cold-rolled specimen with prior intermediate annealing. Tensile properties were also performed to measure the effect of cold rolling and subsequent aging treatment.
NASA Astrophysics Data System (ADS)
Oki, Sae; Natsui, Shungo; Suzuki, Ryosuke O.
2018-01-01
System design of a thermoelectric (TE) power generation module is pursued in order to improve the TE performance. Square truncated pyramid shaped P-N pairs of TE elements are connected electronically in series in the open space between two flat insulator boards. The performance of the TE module consisting of 2-paired elements is numerically simulated using commercial software and original TE programs. Assuming that the heat radiating into the hot surface is regulated, i.e., the amount of heat from the hot surface to the cold one is steadily constant, as it happens for solar radiation heating, the performance is significantly improved by changing the shape and the alignment pattern of the elements. When the angle θ between the edge and the base is smaller than 72°, and when the cold surface is kept at a constant temperature, two patterns in particular, amongst the 17 studied, show the largest TE power and efficiency. In comparison to other geometries, the smarter square truncated pyramid shape can provide higher performance using a large cold bath and constant heat transfer by heat radiation.
NASA Astrophysics Data System (ADS)
Oki, Sae; Natsui, Shungo; Suzuki, Ryosuke O.
2018-06-01
System design of a thermoelectric (TE) power generation module is pursued in order to improve the TE performance. Square truncated pyramid shaped P-N pairs of TE elements are connected electronically in series in the open space between two flat insulator boards. The performance of the TE module consisting of 2-paired elements is numerically simulated using commercial software and original TE programs. Assuming that the heat radiating into the hot surface is regulated, i.e., the amount of heat from the hot surface to the cold one is steadily constant, as it happens for solar radiation heating, the performance is significantly improved by changing the shape and the alignment pattern of the elements. When the angle θ between the edge and the base is smaller than 72°, and when the cold surface is kept at a constant temperature, two patterns in particular, amongst the 17 studied, show the largest TE power and efficiency. In comparison to other geometries, the smarter square truncated pyramid shape can provide higher performance using a large cold bath and constant heat transfer by heat radiation.
Cryotherapy Treatment After Unicompartmental and Total Knee Arthroplasty: A Review.
Chughtai, Morad; Sodhi, Nipun; Jawad, Michael; Newman, Jared M; Khlopas, Anton; Bhave, Anil; Mont, Michael A
2017-12-01
Cryotherapy is widely utilized to enhance recovery after knee surgeries. However, the outcome parameters often vary between studies. Therefore, the purpose of this review is to compare (1) no cryotherapy vs cryotherapy; (2) cold pack cryotherapy vs continuous flow device cryotherapy; (3) various protocols of application of these cryotherapy methods; and (4) cost-benefit analysis in patients who had unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). A search for "knee" and "cryotherapy" using PubMed, EBSCO Host, and SCOPUS was performed, yielding 187 initial reports. After selecting for RCTs relevant to our study, 16 studies were included. Of the 8 studies that compared the immediate postoperative outcomes between patients who did and did not receive cryotherapy, 5 studies favored cryotherapy (2 cold packs and 3 continuous cold flow devices). Of the 6 studies comparing the use of cold packs and continuous cold flow devices in patients who underwent UKA or TKA, 3 favor the use of continuous flow devices. There was no difference in pain, postoperative opioid consumption, or drain output between 2 different temperature settings of continuous cold flow device. The optimal device to use may be one that offers continuous circulating cold flow, as there were more studies demonstrating better outcomes. In addition, the pain relieving effects of cryotherapy may help minimize pain medication use, such as with opioids, which are associated with numerous potential side effects as well as dependence and addiction. Meta-analysis on the most recent RCTs should be performed next. Copyright © 2017 Elsevier Inc. All rights reserved.
Milbury, Coren A.; Chen, Clark C.; Mamon, Harvey; Liu, Pingfang; Santagata, Sandro; Makrigiorgos, G. Mike
2011-01-01
Thorough screening of cancer-specific biomarkers, such as DNA mutations, can require large amounts of genomic material; however, the amount of genomic material obtained from some specimens (such as biopsies, fine-needle aspirations, circulating-DNA or tumor cells, and histological slides) may limit the analyses that can be performed. Furthermore, mutant alleles may be at low-abundance relative to wild-type DNA, reducing detection ability. We present a multiplex-PCR approach tailored to amplify targets of interest from small amounts of precious specimens, for extensive downstream detection of low-abundance alleles. Using 3 ng of DNA (1000 genome-equivalents), we amplified the 1 coding exons (2-11) of TP53 via multiplex-PCR. Following multiplex-PCR, we performed COLD-PCR (co-amplification of major and minor alleles at lower denaturation temperature) to enrich low-abundance variants and high resolution melting (HRM) to screen for aberrant melting profiles. Mutation-positive samples were sequenced. Evaluation of mutation-containing dilutions revealed improved sensitivities after COLD-PCR over conventional-PCR. COLD-PCR improved HRM sensitivity by approximately threefold to sixfold. Similarly, COLD-PCR improved mutation identification in sequence-chromatograms over conventional PCR. In clinical specimens, eight mutations were detected via conventional-PCR-HRM, whereas 12 were detected by COLD-PCR-HRM, yielding a 33% improvement in mutation detection. In summary, we demonstrate an efficient approach to increase screening capabilities from limited DNA material via multiplex-PCR and improve mutation detection sensitivity via COLD-PCR amplification. PMID:21354058
COLD TEMPERATURE MOTOR VEHICLE EMISSIONS TESTING IN ALASKA
A motor vehicle emissions testing study was conducted in Anchorage and Fairbanks during the winter of 1998-99 to collect actual measurements of initial idle emission rates. The study was performed for a sample of 111 automobiles and light-duty trucks under cold wintertime ambient...
A Compact, High-Flux Cold Atom Beam Source
NASA Technical Reports Server (NTRS)
Kellogg, James R.; Kohel, James M.; Thompson, Robert J.; Aveline, David C.; Yu, Nan; Schlippert, Dennis
2012-01-01
The performance of cold atom experiments relying on three-dimensional magneto-optical trap techniques can be greatly enhanced by employing a highflux cold atom beam to obtain high atom loading rates while maintaining low background pressures in the UHV MOT (ultra-high vacuum magneto-optical trap) regions. Several techniques exist for generating slow beams of cold atoms. However, one of the technically simplest approaches is a two-dimensional (2D) MOT. Such an atom source typically employs at least two orthogonal trapping beams, plus an additional longitudinal "push" beam to yield maximum atomic flux. A 2D atom source was created with angled trapping collimators that not only traps atoms in two orthogonal directions, but also provides a longitudinal pushing component that eliminates the need for an additional push beam. This development reduces the overall package size, which in turn, makes the 2D trap simpler, and requires less total optical power. The atom source is more compact than a previously published effort, and has greater than an order of magnitude improved loading performance.
Faramarzi, Abolahassan; Heydari, Seyed Taghi
2010-01-01
Objective Post-tonsillectomy hemorrhage remains an important factor in determining the safety of performing tonsillectomy as a day case procedure. The aim of this study was to determine the safety of day case tonsillectomy by using combination method, cold dissection tonsillectomy and bipolar diathermy hemostasis. Methods A prospective randomized clinical study conducted on the patients who had undergone day case tonsillectomy (DCT). There were two groups (DCT and control group) each group consisting of 150 cases. Tonsillectomy was performed by using combination method; cold dissection and hemostasis was achieved by ligation of vessels with bipolar electerocautery. Findings We found 3 cases of post-tonsillectomy bleeding in DCT group and 4 cases in the control group. There was no statistically significant difference in the rate of post-operative hemorrhage between the two groups. Conclusion The findings suggest the safety of the combination of cold dissection tonsillectomy and bipolar diathermy hemostasis as day case tonsillectomy. PMID:23056702
Santin, Joseph M; Hartzler, Lynn K
2017-04-01
Semiaquatic frogs may not breathe air for several months because they overwinter in ice-covered ponds. In contrast to many vertebrates that experience decreased motor performance after inactivity, bullfrogs, Lithobates catesbeianus , retain functional respiratory motor processes following cold-submergence. Unlike mammalian hibernators with unloaded limb muscles and inactive locomotor systems, respiratory mechanics of frogs counterintuitively allow for ventilatory maneuvers when submerged. Thus, we hypothesized that bullfrogs generate respiratory motor patterns during cold-submergence to avoid disuse and preserve motor performance. Accordingly, we measured activity of respiratory muscles (buccal floor compressor and glottal dilator) via electromyography in freely behaving bullfrogs at 20 and 2°C. Although we confirm that ventilation cycles occur underwater at 20°C, bullfrogs did not activate either respiratory muscle when submerged acutely or chronically at 2°C. We conclude that cold-submerged bullfrogs endure respiratory motor inactivity, implying that other mechanisms, excluding underwater muscle activation, maintain a functional respiratory motor system throughout overwintering. © 2017. Published by The Company of Biologists Ltd.
Peripheral cold acclimatization in Antarctic scuba divers.
Bridgman, S A
1991-08-01
Peripheral acclimatization to cold in scuba divers stationed at the British Antarctic Survey's Signy Station was investigated during a year in Antarctica. Five divers and five non-diver controls underwent monthly laboratory tests of index finger immersion in cold water for 30 min. Index finger pulp temperature and time of onset of cold-induced vasodilatation (CIVD) were measured. Pain was recorded with verbal and numerical psychophysical subjective pain ratings. Average finger temperatures and median finger pain from 6-30 min of immersion, maximum finger temperatures during the first CIVD cycle, and finger temperatures at the onset of CIVD were calculated. Comparison of the variables recorded from divers and non-divers were performed with analysis of variance. No significant differences were found among the variables recorded from divers and non-divers. From a review of the literature, divers have responses typical of non-cold-adapted Caucasians. There is, therefore, no evidence that Signy divers peripherally acclimatized to cold. We suggest that these findings occur because either the whole body cooling which divers undergo inhibits peripheral acclimatization or because of insufficiently frequent or severe cold exposure while diving. Further basic studies on the duration, frequency and severity of cold exposure necessary to induce peripheral cold acclimatization are required before this question can be satisfactorily answered.
Fujii, Naoto; Aoki-Murakami, Erii; Tsuji, Bun; Kenny, Glen P; Nagashima, Kei; Kondo, Narihiko; Nishiyasu, Takeshi
2017-11-01
We evaluated cold sensation at rest and in response to exercise-induced changes in core and skin temperatures in cold-sensitive exercise trained females. Fifty-eight trained young females were screened by a questionnaire, selecting cold-sensitive (Cold-sensitive, n = 7) and non-cold-sensitive (Control, n = 7) individuals. Participants rested in a room at 29.5°C for ~100 min after which ambient temperature was reduced to 23.5°C where they remained resting for 60 min. Participants then performed 30-min of moderate intensity cycling (50% peak oxygen uptake) followed by a 60-min recovery. Core and mean skin temperatures and cold sensation over the whole-body and extremities (fingers and toes) were assessed throughout. Resting core temperature was lower in the Cold-sensitive relative to Control group (36.4 ± 0.3 vs. 36.7 ± 0.2°C). Core temperature increased to similar levels at end-exercise (~37.2°C) and gradually returned to near preexercise rest levels at the end of recovery (>36.6°C). Whole-body cold sensation was greater in the Cold-sensitive relative to Control group during resting at a room temperature of 23.5°C only without a difference in mean skin temperature between groups. In contrast, cold sensation of the extremities was greater in the Cold-sensitive group prior to, during and following exercise albeit this was not paralleled by differences in mean extremity skin temperature. We show that young trained females who are sensitive to cold exhibit augmented whole-body cold sensation during rest under temperate ambient conditions. However, this response is diminished during and following exercise. In contrast, cold sensation of extremities is augmented during resting that persists during and following exercise. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Variation of DNA Methylome of Zebrafish Cells under Cold Pressure
Xu, Qiongqiong; Luo, Juntao; Shi, Yingdi; Li, Xiaoxia; Yan, Xiaonan; Zhang, Junfang
2016-01-01
DNA methylation is an essential epigenetic mechanism involved in multiple biological processes. However, the relationship between DNA methylation and cold acclimation remains poorly understood. In this study, Methylated DNA Immunoprecipitation Sequencing (MeDIP-seq) was performed to reveal a genome-wide methylation profile of zebrafish (Danio rerio) embryonic fibroblast cells (ZF4) and its variation under cold pressure. MeDIP-seq assay was conducted with ZF4 cells cultured at appropriate temperature of 28°C and at low temperature of 18°C for 5 (short-term) and 30 (long-term) days, respectively. Our data showed that DNA methylation level of whole genome increased after a short-term cold exposure and decreased after a long-term cold exposure. It is interesting that metabolism of folate pathway is significantly hypomethylated after short-term cold exposure, which is consistent with the increased DNA methylation level. 21% of methylation peaks were significantly altered after cold treatment. About 8% of altered DNA methylation peaks are located in promoter regions, while the majority of them are located in non-coding regions. Methylation of genes involved in multiple cold responsive biological processes were significantly affected, such as anti-oxidant system, apoptosis, development, chromatin modifying and immune system suggesting that those processes are responsive to cold stress through regulation of DNA methylation. Our data indicate the involvement of DNA methylation in cellular response to cold pressure, and put a new insight into the genome-wide epigenetic regulation under cold pressure. PMID:27494266
Brophy-Williams, Ned; Landers, Grant; Wallman, Karen
2011-01-01
The purpose of the study was to determine the effects of cold water immersion (CWI) performed immediately or 3 h after a high intensity interval exercise session (HIIS) on next-day exercise performance. Eight male athletes performed three HIIS at 90%VO2max velocity followed by either a passive recovery (CON), CWI performed immediately post-exercise (CWI(0)) or CWI performed 3 h post-exercise (CWI(3)). Recovery trials were performed in a counter balanced manner. Participants then returned 24 h later and completed a muscle soreness and a totally quality recovery perception (TQRP) questionnaire, which was then followed by the Yoyo Intermittent Recovery Test [level 1] (YRT). Venous blood samples were collected pre-HIIS and pre-YRT to determine C-Reactive Protein (CRP) levels. Significantly more shuttles were performed during the YRT following CWI(0) compared to the CON trial (p=0.017, ES = 0. 8), while differences between the CWI(3) and the CON trials approached significance (p = 0.058, ES = 0.5). Performance on the YRT between the CWI(0) and CWI(3) trials were similar (p = 0.147, ES = 0. 3). Qualitative analyses demonstrated a 98% and 92% likely beneficial effect of CWI(0) and CWI(3) on next day performance, compared to CON, respectively, while CWI(0) resulted in a 79% likely benefit when compared to CWI(3). CRP values were significantly lower pre-YRT, compared to baseline, following CWI(0) (p = 0.0.36) and CWI(3) (p = 0.045), but were similar for CON (p = 0.157). Muscle soreness scores were similar between trials (p = 1.10), while TQRP scores were significantly lower for CON compared to CWI(0) (p = 0.002 ) and CWI(3) (p = 0.024). Immediate CWI resulted in superior next-day YRT performance compared to CON, while delayed (3 h) CWI was also likely to be beneficial. Qualitative analyses suggested that CWI(0) resulted in better performance than CWI(3). These results are important for athletes who do not have immediate access to CWI following exercise. Key pointsPerformance of cold water immersion as a recovery procedure following exercise is better than performing no recovery procedureAthletes, coaches and sport trainers should implement cold water immersion post-exercise irrespective of the time of administration.Where possible, cold water immersion should be performed immediately post-exercise to gain maximal recovery benefits.
Tian, Xin; Liu, Ying; Huang, Zhigang; Duan, Huaping; Tong, Jianhua; He, Xiaoling; Gu, Weihong; Ma, Hao; Xiao, Langtao
2015-03-01
Cold stress adversely affects the growth and development of seedling of spring soybean. Revealing responses in seedling to cold stress at proteomic level will help us to breed cold-tolerant spring soybean cultivars. In this study, to understand the responses, a proteomic analysis on the leaves of seedlings of one cold-tolerant soybean cultivar and one cold-sensitive soybean cultivar at 5°C for different times (12 and 24 h) was performed, with some proteomic results being further validated by physiological and biochemical analysis. Our results showed that 57 protein spots were found to be significantly changed in abundance and identified by MALDI-TOF/TOF MS. All the identified proteins were found to be involved in 13 metabolic pathways and cellular processes, including photosynthesis, protein folding and assembly, cell rescue and defense, cytoskeletal proteins, transcription and translation regulation, amino acid and nitrogen metabolism, protein degradation, storage proteins, signal transduction, carbohydrate metabolism, lipid metabolism, energy metabolism, and unknown. Based on the majority of the identified cold-responsive proteins, the effect of cold stress on seedling leaves of the two spring soybean cultivars was discussed. The reason that soybean cv. Guliqing is more cold-tolerant than soybean cv. Nannong 513 was due to its more protein, lipid and polyamine biosynthesis, more effective sulfur-containing metabolite recycling, and higher photosynthetic rate, as well as less ROS production and lower protein proteolysis and energy depletion under cold stress. Such a result will provide more insights into cold stress responses and for further dissection of cold tolerance mechanisms in spring soybean.
Nozzle Side Load Testing and Analysis at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Ruf, Joseph H.; McDaniels, David M.; Brown, Andrew M.
2009-01-01
Realistic estimates of nozzle side loads, the off-axis forces that develop during engine start and shutdown, are important in the design cycle of a rocket engine. The estimated magnitude of the nozzle side loads has a large impact on the design of the nozzle shell and the engine s thrust vector control system. In 2004 Marshall Space Flight Center (MSFC) began developing a capability to quantify the relative magnitude of side loads caused by different types of nozzle contours. The MSFC Nozzle Test Facility was modified to measure nozzle side loads during simulated nozzle start. Side load results from cold flow tests on two nozzle test articles, one with a truncated ideal contour and one with a parabolic contour are provided. The experimental approach, nozzle contour designs and wall static pressures are also discussed
Genetic variation of germination cold tolerance in Japanese rice germplasm
Bosetti, Fátima; Montebelli, Camila; Novembre, Ana Dionísia L.C.; Chamma, Helena Pescarin; Pinheiro, José Baldin
2012-01-01
Low temperatures at the initial stages of rice development prevent fast germination and seedling establishment and may cause significant productivity losses. In order to develop rice cultivars exhibiting cold tolerance, it is necessary to investigate genetic resources, providing basic knowledge to allow the introduction of genes involved in low temperature germination ability from accessions into elite cultivars. Japanese rice accessions were evaluated at the germination under two conditions: 13°C for 28 days (cold stress) and 28°C for seven days (optimal temperature). The traits studied were coleoptile and radicle length under optimal temperature, coleoptile and radicle length under cold and percentage of the reduction in coleptile and radicle length due to low temperature. Among the accessions studied, genetic variation for traits related to germination under low temperatures was observed and accessions exhibiting adequate performance for all investigated traits were identified. The use of multivariate analysis allowed the identification of the genotypes displaying cold tolerance by smaller reductions in coleoptile and radicle lenght in the presence of cold and high vigour, by higher coleoptile and radicle growth under cold. PMID:23226080
Genetic variation of germination cold tolerance in Japanese rice germplasm.
Bosetti, Fátima; Montebelli, Camila; Novembre, Ana Dionísia L C; Chamma, Helena Pescarin; Pinheiro, José Baldin
2012-09-01
Low temperatures at the initial stages of rice development prevent fast germination and seedling establishment and may cause significant productivity losses. In order to develop rice cultivars exhibiting cold tolerance, it is necessary to investigate genetic resources, providing basic knowledge to allow the introduction of genes involved in low temperature germination ability from accessions into elite cultivars. Japanese rice accessions were evaluated at the germination under two conditions: 13°C for 28 days (cold stress) and 28°C for seven days (optimal temperature). The traits studied were coleoptile and radicle length under optimal temperature, coleoptile and radicle length under cold and percentage of the reduction in coleptile and radicle length due to low temperature. Among the accessions studied, genetic variation for traits related to germination under low temperatures was observed and accessions exhibiting adequate performance for all investigated traits were identified. The use of multivariate analysis allowed the identification of the genotypes displaying cold tolerance by smaller reductions in coleoptile and radicle lenght in the presence of cold and high vigour, by higher coleoptile and radicle growth under cold.
Effect of thermal stresses on the mechanism of tooth pain.
Oskui, Iman Z; Ashtiani, Mohammed N; Hashemi, Ata; Jafarzadeh, Hamid
2014-11-01
Daily hot and cold thermal loadings on teeth may result in structural deformation, mechanical stress, and pain signaling. The aim of this study was to compare the adverse effects of hot and cold beverages on an intact tooth and, then, to provide physical evidence to support the hydrodynamic theory of tooth pain sensation mechanism. Three-dimensional finite element analysis was performed on a premolar model subjected to hot and cold thermal loadings. Elapsed times for heat diffusion and stress detection at the pulp-dentin junction were calculated as measures of the pain sensation. Extreme tensile stress within the enamel resulted in damage in cold loadings. Also, extreme values of stress at the pulpal wall occurred 21.6 seconds earlier than extreme temperatures in hot and cold loadings. The intact tooth was remarkably vulnerable to cold loading. Earlier changes in mechanical stress rather than temperature at the pulp-dentin junction indicate that the dental pain caused by hot or cold beverages may be based on the hydrodynamic theory. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
SIKA—the multiplexing cold-neutron triple-axis spectrometer at ANSTO
NASA Astrophysics Data System (ADS)
Wu, C.-M.; Deng, G.; Gardner, J. S.; Vorderwisch, P.; Li, W.-H.; Yano, S.; Peng, J.-C.; Imamovic, E.
2016-10-01
SIKA is a new cold-neutron triple-axis spectrometer receiving neutrons from the cold source CG4 of the 20MW Open Pool Australian Light-water reactor. As a state-of-the-art triple-axis spectrometer, SIKA is equipped with a large double-focusing pyrolytic graphite monochromator, a multiblade pyrolytic graphite analyser and a multi-detector system. In this paper, we present the design, functions, and capabilities of SIKA, and discuss commissioning experimental results from powder and single-crystal samples to demonstrate its performance.
NASA Astrophysics Data System (ADS)
Sych, O. V.; Khlusova, E. I.; Yashin, E. A.
2017-12-01
The paper presents the results of quantitative analysis of C, Mn, Ni and Cu content on strength and cold-resistance of rolled plates. Relations between the ferritic-bainitic structure morphology and anisotropy and steel performance characteristics have been established. Influence of thermal and deformation rolling patterns on steel structure has been studied. The steel chemical composition has been improved and precision thermomechanical processing conditions for production of cold-resistant Arc-steel plates have been developed.
Imaging of Rabbit VX-2 Hepatic Cancer by Cold and Thermal Neutron Radiography
NASA Astrophysics Data System (ADS)
Tsuchiya, Yoshinori; Matsubayashi, Masahito; Takeda, Tohoru; Lwin, Thet Thet; Wu, Jin; Yoneyama, Akio; Matsumura, Akira; Hori, Tomiei; Itai, Yuji
2003-11-01
Neutron radiography is based on differences in neutron mass attenuation coefficients among the elements and is a non-destructive imaging method. To investigate biomedical applications of neutron radiography, imaging of rabbit VX-2 liver cancer was performed using thermal and cold neutron radiography with a neutron imaging plate. Hepatic vessels and VX-2 tumor were clearly observed by neutron radiography, especially by cold neutron imaging. The image contrast of this modality was better than that of absorption-contrast X-ray radiography.
Green mosses date the Storegga tsunami to the chilliest decades of the 8.2 ka cold event
NASA Astrophysics Data System (ADS)
Bondevik, Stein; Stormo, Svein Kristian; Skjerdal, Gudrun
2012-06-01
Chlorophyll in dead plants ordinarily decomposes completely before permanent burial through exposure to light, water and oxygen. Here we describe 8000-year-old terrestrial mosses that retain several percent of its original chlorophyll. The mosses were ripped of the land surface, carried 50-100 m off the Norwegian coast of the time, and deposited in depressions on the sea floor by the Storegga tsunami. A little of the chlorophyll survived because, within hours after entraining it, the tsunami buried the mosses in shell-rich sediments. These sediments preserved the chlorophyll by keeping out light and oxygen, and by keeping the pH above 7—three factors known to favour chlorophyll's stability. Because the green mosses were buried alive, their radiocarbon clock started ticking within hours after the Storegga Slide had set off the tsunami. Radiocarbon measurement of the mosses therefore give slide ages of uncommon geological precision, and these, together with a sequence of ages above and below the boundary, date the Storegga Slide to the chilliest decades of the 8.2 ka cold event at 8120-8175 years before AD 1950. North Atlantic coastal- and fjord- climatic records claimed to show evidence of the 8.2 cold event should be carefully examined for possible contamination and disturbance from the Storegga tsunami.
NASA Astrophysics Data System (ADS)
Auber, Arnaud; Gohin, Francis; Goascoz, Nicolas; Schlaich, Ivan
2017-04-01
A growing number of studies have documented increasing dominance of warm-water fish species ("tropicalisation") in response to ocean warming. Such reorganization of communities is starting to occur in a multitude of local ecosystems, implying that tropicalisation of marine communities could become a global phenomenon. Using 32 years of trawl surveys in the Bay of Somme (English Channel, France), we aimed to investigate the existence of a tropicalisation in the fish community at the local scale of the estuary during the mid-1990s, a period where an exceptional temperature rise occurred in Northeast Atlantic. A long-term response occurred (with a major transition over 6 years) that was characterized by a marked diminution in the abundance of cold-water species in parallel to a temperature rise generated by the ocean-scale phenomenon, the Atlantic Multidecadal Oscillation, which switched from a cool to a warm phase during the late 1990s. Despite finding no significant increase in the dominance of warm-water species, the long-term diminution of cold-water species suggests that the restructuring of the fish community was mainly influenced by global-scale environmental conditions rather than local ones and that indirect effects may also occurred through biological interactions.
Keefe, F J; Surwit, R S; Pilon, R N
1980-01-01
Twenty-one female patients suffering from diagnosed idiopathic Raynaud's Disease were trained to raise digital skin temperature using either autogenic training, progressive muscle relaxation, or a combination of autogenic training and skin temperature feedback. Patients were instructed in the treatment procedures in three one-hour group sessions spaced one week apart. All patients were instructed to practice what they had learned twice a day at home. Patients kept records of the frequency of vasospastic attacks occurring over a four-week baseline period, and during the first four weeks and the ninth week of training. In addition, patients underwent four laboratory cold stress tests during which they were instructed to maintain digital temperature as the ambient temperature was slowly dropped from 26 degrees to 17 degrees C. Cold stress tests were given during week 1 of baseline and during weeks 1, 3, and 5 of training. No significant differences between the three behavioral treatment procedures were obtained. In addition, the ability of patients to maintain digital temperature during the cold stress challenge showed significant improvement from the first to the last tests. Symptomatic improvement was maintained by all patients nine weeks after the start of training. The implications of these findings for the behavioral treatment of Raynaud's Disease are discussed. PMID:6988380
Effects of four recovery methods on repeated maximal rock climbing performance.
Heyman, Elsa; DE Geus, Bas; Mertens, Inge; Meeusen, Romain
2009-06-01
Considering the development of rock climbing as a competitive sport, we aimed at investigating the influence of four recovery methods on subsequent maximal climbing performance. In a randomly assigned crossover design, 13 female well-trained climbers (27.1 +/- 8.9 yr) came to the climbing center on four occasions separated by 1 wk. On each occasion, they had to perform two climbing tests (C1 and C2) until volitional exhaustion on a prepracticed route (overhanging wall, level 6b). These two tests were separated by 20 min of recovery. Four recovery methods were used in randomized order: passive recovery, active recovery (cycle ergometer, 30-40 W), electromyostimulation on the forearm muscles (bisymmetric TENS current), or cold water immersion of the forearms and arms (three periods of 5 min at 15 +/- 1 degrees C). Climbing tests' performance was reflected by the number of arm movements and climb duration. Using active recovery and cold water immersion, performance at C2 was maintained in comparison with C1, whereas C2 performance was impaired compared with C1 (P< 0.01) using electromyostimulation and passive recovery (recovery method-by-climb interaction, P < 0.05). Blood lactate decreased during recovery, with the greatest decrease occurring during active recovery (time-by-recovery method interaction, P < 0.001). Arms and forearms' skin temperatures were lower throughout the cold water immersion compared with the other three methods (P < 0.001). Active recovery and cold water immersion are two means of preserving performance when repeating acute exhausting climbing trails in female climbers. These positive effects are accompanied by a greater lactate removal and a decrease in subcutaneous tissues temperatures, respectively.
The Use of Particle/Substrate Material Models in Simulation of Cold-Gas Dynamic-Spray Process
NASA Astrophysics Data System (ADS)
Rahmati, Saeed; Ghaei, Abbas
2014-02-01
Cold spray is a coating deposition method in which the solid particles are accelerated to the substrate using a low temperature supersonic gas flow. Many numerical studies have been carried out in the literature in order to study this process in more depth. Despite the inability of Johnson-Cook plasticity model in prediction of material behavior at high strain rates, it is the model that has been frequently used in simulation of cold spray. Therefore, this research was devoted to compare the performance of different material models in the simulation of cold spray process. Six different material models, appropriate for high strain-rate plasticity, were employed in finite element simulation of cold spray process for copper. The results showed that the material model had a considerable effect on the predicted deformed shapes.
Tanabe, Natsumi; Takane, Koki; Yokoyama, Keitaro; Tanno, Yudo; Yamamoto, Izumi; Ohkido, Ichiro; Yokoo, Takashi
2014-09-17
Baroreflex failure syndrome is a rare disorder which causes labile blood pressure, headache, flushing, diaphoresis and emotional lability. It is caused by history of trauma or radiotherapy in the cervical legion, bilateral carotid-body tumor or resection of glossopharyngeal nerve. We experienced a case of hemodialysis patient who had difficulty in controlling blood pressure during dialysis because of his baroreflex failure syndrome and successfully controlled his blood pressure by adjusting dialysate temperature. We report a case of a 68-year-old CKD5 patient who had difficulty in hemodialysis treatment because of severe fluctuations in blood pressure with hypertensive attacks and hypotensive episodes which caused him a severe discomfort. His dialysis treatment was started in 2010 and since that time baroreflex failure syndrome has been suspected because of his clinical manifestations and history of radiotherapy in the cervical region for his lingual cancer in 1994. Baroreflex failure syndrome is diagnosed by symptoms and cold stressor test. We performed a cold stressor test on an experimental baroreflex failure syndrome mouse and induced a significant elevation of blood pressure. From this experimental finding of model mouse, we changed the patients dialysate temperature between 34-38° according to his change in blood pressure though 80-240 mmHg. From this attempt, his blood pressure was successfully controlled between 100-180 mmHg and he was able to continue hemodialysis without any discomfort. In our case, environmental stimulation such as temperature change modified the patients fluctuating blood pressure. Change of dialysate temperature could be an option for controlling the unstable blood pressure due to baroreflex failure syndrome.
Zarcone, M C; Duistermaat, E; Alblas, M J; van Schadewijk, A; Ninaber, D K; Clarijs, V; Moerman, M M; Vaessen, D; Hiemstra, P S; Kooter, I M
2018-04-01
Harmful effects of diesel emissions can be investigated via exposures of human epithelial cells, but most of previous studies have largely focused on the use of diesel particles or emission sources that are poorly representative of engines used in current traffic. We studied the cellular response of primary bronchial epithelial cells (PBECs) at the air-liquid interface (ALI) to the exposure to whole diesel exhaust (DE) generated by a Euro V bus engine, followed by treatment with UV-inactivated non-typeable Haemophilus influenzae (NTHi) bacteria to mimic microbial exposure. The effect of prolonged exposures was investigated, as well as the difference in the responses of cells from COPD and control donors and the effect of emissions generated during a cold start. HMOX1 and NQO1 expression was transiently induced after DE exposure. DE inhibited the NTHi-induced expression of human beta-defensin-2 (DEFB4A) and of the chaperone HSPA5/BiP. In contrast, expression of the stress-induced PPP1R15A/GADD34 and the chemokine CXCL8 was increased in cells exposed to DE and NTHi. HMOX1 induction was significant in both COPD and controls, while inhibition of DEFB4A expression by DE was significant only in COPD cells. No significant differences were observed when comparing cellular responses to cold engine start and prewarmed engine emissions. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
A 24-year-old male with a painful and cold lower extremity.
Robinson, Eric A; Khalpey, Zain I; Janardhanan, Rajesh
2017-05-01
A 24-year-old male presented to the emergency department with intense pain in his right lower extremity. He has a medical history significant for systemic lupus erythematosus and antiphospholipid syndrome. He also had four prior episodes of deep venous thromboses on rivaroxaban. The patient stated that early in the morning, he started to feel intense pain that started from his knee and progressed to his calf, with associated numbness and paraesthesia. On physical examination, the limb felt cold with absent right popliteal and dorsalis pedis pulses. He was immediately taken for embolectomy after discovery of a distal common femoral artery occlusion. The patient's blood cultures remained negative. X-plane imaging on real-time three-dimensional transoesophageal echocardiography (RT-3DTEE) of the aortic valve (figure 1A) and colour Doppler (figure 1B) are shown. What is the diagnosis and management for this patient (assuming the patient will stay anticoagulated for life)? Infective endocarditis (IE); antibiotics and valve replacementLibman-Sacks endocarditis; corticosteroidsIE; antibiotics onlyLibman-Sacks endocarditis; valve replacementLibman-Sacks endocarditis; continuing anticoagulation only heartjnl;103/10/765/HEARTJNL2016310872F1F1HEARTJNL2016310872F1Figure 1Visualisation of the aortic valve on (A) X-plane imaging on real-time three-dimensional transoesophageal echocardiography (RT-3DTEE) and (B) colour Doppler. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Kluth, Karsten; Baldus, Sandra; Strasser, Helmut
2012-01-01
The sales figures of chilled and frozen food have been rising steadily over the years. Naturally, this has also led to an increase in the number of jobs related to these goods. While these workplaces are becoming more and more important there are, nevertheless, only a few investigations into the effects of working in deep cold on humans. Order-picking in a cold environment represents a high workload. Especially working at -24°C with wearing heavy cold protective clothing leads to explicitly higher strain. Since performance decreases with age, varying physical strain between younger and older employees can hypothetically be expected. In order to quantify the physiological responses to working in the cold, 15 subjects of two female age groups, each, (20- to 35-year-olds and 40- to 65-year-olds) were asked to carry out whole working day tasks in a chill room (+3°) and in a cold store (-24°C). Simultaneously, heart rate and other physiological relevant parameters were measured.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shingledecker, John P
2007-01-01
Creep-rupture experiments were conducted on HR6W and Haynes 230, candidate Ultrasupercritical (USC) alloys, tubes to evaluate the effects of cold-work and recrystallization during high-temperature service. These creep tests were performed by internally pressurizing cold-bent boiler tubes at 775 C for times up to 8000 hours. The bends were fabricated with cold-work levels beyond the current ASME Boiler and Pressure Vessel (ASME B&PV) Code Section I limits for austenitic stainless steels. Destructive metallographic evaluation of the crept tube bends was used to determine the effects of cold-work and the degree of recrystallization. The metallographic analysis combined with an evaluation of themore » creep and rupture data suggest that solid-solution strengthened nickel-based alloys can be fabricated for high-temperature service at USC conditions utilizing levels of cold-work higher than the current allowed levels for austenitic stainless steels.« less
The control system of a 2kW@20K helium refrigerator
NASA Astrophysics Data System (ADS)
Pan, W.; Wu, J. H.; Li, Qing; Liu, L. Q.; Li, Qiang
2017-12-01
The automatic control of a helium refrigerator includes three aspects, that is, one-button start and stop control, safety protection control, and cooling capacity control. The 2kW@20K helium refrigerator’s control system uses the SIEMENS PLC S7-300 and its related programming and configuration software Step7 and the industrial monitoring software WinCC, to realize the dynamic control of its process, the real-time monitoring of its data, the safety interlock control, and the optimal control of its cooling capacity. At first, this paper describes the control architecture of the whole system in detail, including communication configuration and equipment introduction; and then introduces the sequence control strategy of the dynamic processes, including the start and stop control mode of the machine and the safety interlock control strategy of the machine; finally tells the precise control strategy of the machine’s cooling capacity. Eventually, the whole system achieves the target of one-button starting and stopping, automatic fault protection and stable running to the target cooling capacity, and help finished the cold helium pressurization test of aerospace products.
21 CFR 1020.20 - Cold-cathode gas discharge tubes.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR IONIZING RADIATION EMITTING PRODUCTS § 1020.20 Cold-cathode gas... discharge tubes designed to demonstrate the effects of a flow of electrons or the production of x-radiation... cathode. Exit beam means that portion of the radiation which passes through the aperture resulting from...
7 CFR 305.6 - Cold treatment requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... APHIS must agree in advance on the route by which consignments are allowed to move between the aircraft... procedures. (1) All material, labor, and equipment for cold treatment performed on a vessel must be provided... be given the appropriate materials and access to the facility, container, or vessel necessary to...
40 CFR 86.1432 - Vehicle preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... transient test procedure—(1) CST performed as a stand-alone procedure. For the first CST compliance pathway... cold temperature compliance pathway, the temperature of the fuel prior to its delivery to the fuel tank... operation, or any of the succeeding steps in the CST sequence. (ii) For the cold temperature pathway only...
40 CFR 86.1432 - Vehicle preparation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... transient test procedure—(1) CST performed as a stand-alone procedure. For the first CST compliance pathway... cold temperature compliance pathway, the temperature of the fuel prior to its delivery to the fuel tank... operation, or any of the succeeding steps in the CST sequence. (ii) For the cold temperature pathway only...
DOT National Transportation Integrated Search
2016-05-01
This report looks into how a successful Cold In-Place solventless emulsion behaves and how the emulsion : break test developed in Phase III of this project demonstrates that behavior. Modifications to the test have been : made to improve the consiste...
USDA-ARS?s Scientific Manuscript database
The alfalfa leafcutting bee, Megachile rotundata, undergoes metamorphosis in the spring when temperatures can be highly variable. It is unknown how cold tolerance varies across metamorphosis. We found earlier stages were more tolerant to cold exposure than later stages. Furthermore, we found exposur...
Bimodal gas accretion in the Horizon-MareNostrum galaxy formation simulation
NASA Astrophysics Data System (ADS)
Ocvirk, P.; Pichon, C.; Teyssier, R.
2008-11-01
The physics of diffuse gas accretion and the properties of the cold and hot modes of accretion on to proto-galaxies between z = 2 and 5.4 is investigated using the large cosmological simulation performed with the RAMSES code on the MareNostrum supercomputing facility. Galactic winds, chemical enrichment, ultraviolet background heating and radiative cooling are taken into account in this very high resolution simulation. Using accretion-weighted temperature histograms, we have performed two different measurements of the thermal state of the gas accreted towards the central galaxy. The first measurement, performed using accretion-weighted histograms on a spherical surface of radius 0.2Rvir centred on the densest gas structure near the halo centre of mass, is a good indicator of the presence of an accretion shock in the vicinity of the galactic disc. We define the hot shock mass, Mshock, as the typical halo mass separating cold dominated from hot dominated accretion in the vicinity of the galaxy. The second measurement is performed by radially averaging histograms between 0.2Rvir and Rvir, in order to detect radially extended structures such as gas filaments: this is a good proxy for detecting cold streams feeding the central galaxy. We define Mstream as the transition mass separating cold dominated from hot dominated accretion in the outer halo, marking the disappearance of these cold streams. We find a hot shock transition mass of Mshock = 1011.6Msolar (dark matter), with no significant evolution with redshift. Conversely, we find that Mstream increases sharply with z. Our measurements are in agreement with the analytical predictions of Birnboim & Dekel and Dekel & Birnboim, if we correct their model by assuming low metallicity (<=10-3Zsolar) for the filaments, correspondingly to our measurements. Metal enrichment of the intergalactic medium is therefore a key ingredient in determining the transition mass from cold to hot dominated diffuse gas accretion. We find that the diffuse cold gas supply at the inner halo stops at z = 2 for objects with stellar masses of about 1011.1Msolar, which is close to the quenching mass determined observationally by Bundy et al. However, its evolution with z is not well constrained, making it difficult to rule out or confirm the need for an additional feedback process such as active galactic nuclei.
Ontogeny of decapod crustacean hemocyanin: effects of temperature and nutrition.
Terwilliger, N; Dumler, K
2001-03-01
Hemocyanin is present throughout the decapod crustacean's life, usually as one-hexamer and two-hexamer oligomers. Hemocyanins of some decapod crustaceans undergo changes in subunit composition and oxygen affinity during development. Maternal hemocyanin is taken up from the hemolymph via endocytosis by the oocyte. Embryo hemocyanin differs in subunit composition from hemocyanin of oocyte and adult crab and may represent the onset of hemocyanin synthesis. Complex changes in expression of hemocyanin subunits occur through megalopa and early juvenile stages of the crab Cancer magister, culminating in the pattern of adult hemocyanin. The influences of food availability and temperature on development, growth and hemocyanin ontogeny in early juvenile C. magister have been studied. Crabs were raised in warm or cold sea water and fed high or low levels of food for 6 months. While intermolt period was shorter in crabs fed high food levels, especially those raised in warm water, crabs reared in cold water with high food levels attained the largest sizes. Thus increased food availability affects growth more than increased temperature. Adult hemocyanin appeared at about the same number of weeks after the start of the experiment for crabs in the warm water/high food, warm water/low food and cold water/high food groups, even though warm water/low food crabs had molted fewer times. Crabs in the cold water/low food group expressed adult hemocyanin much later than the other groups. Molt stage and maturation from juvenile to adult are not absolutely coupled, and food availability has a greater influence than temperature on hemocyanin ontogeny.
Development of a hybrid chemical/mechanical heat pump
NASA Technical Reports Server (NTRS)
Grzyll, Lawrence R.; Silvestri, John J.; Scaringe, Robert P.
1991-01-01
The authors present the current development status of a hybrid chemical/mechanical heat pump for low-lift applications. The heat pump provides electronics cooling by evaporating a pure refrigerant from an absorbent/refrigerant mixture in a generator/cold plate. The current development focused on evaluation of absorbent/refrigerant pairs, corrosion testing, pump and compressor design, and electronic cold plate design. Two cycle configurations were considered. The first configuration utilized a standard mechanical compressor and pump. The second cycle configuration investigated pumps and compressors with non-moving parts. An innovative generator/cold plate design is also presented. The development to date shows that this cycle has about the same performance as standard vapor compression heat pumps with standard refrigerants but may have some performance and reliability advantages over vapor compression heat pumps.
NASA Technical Reports Server (NTRS)
Morehead, R. L.; Atwell, M. J.; Melcher, J. C.; Hurlbert, E. A.
2016-01-01
A prototype cold helium active pressurization system was incorporated into an existing liquid oxygen (LOX) / liquid methane (LCH4) prototype planetary lander and hot-fire tested to collect vehicle-level performance data. Results from this hot-fire test series were used to validate integrated models of the vehicle helium and propulsion systems and demonstrate system effectiveness for a throttling lander. Pressurization systems vary greatly in complexity and efficiency between vehicles, so a pressurization performance metric was also developed as a means to compare different active pressurization schemes. This implementation of an active repress system is an initial sizing draft. Refined implementations will be tested in the future, improving the general knowledge base for a cryogenic lander-based cold helium system.
Cold atom quantum sensors for space
NASA Astrophysics Data System (ADS)
Singh, Yeshpal
2016-07-01
Quantum sensors based on cold atoms offer the opportunity to perform highly accurate measurements of physical phenomena related to time, gravity and rotation. The deployment of such technologies in the microgravity environment of space may enable further enhancement of their performance, whilst permitting the detection of these physical phenomena over much larger scales than is possible with a ground-based instrument. In this talk, I will present an overview of the activities of the UK National Quantum Hub in Sensors and Metrology in developing cold atoms technology for space. Our activities are focused in two main areas: optical clocks and atom interferometers. I will also discuss our contributions to recent initiatives including STE-QUEST and AI-GOAT, the ESA/NASA initiative aiming at an atom interferometer gravitational wave detector in space.
Zimmerman, David L; Ownsworth, Tamara; O'Donovan, Analise; Roberts, Jacqueline; Gullo, Matthew J
2016-01-01
Individuals with autistic spectrum disorder (ASD) display diverse deficits in social, cognitive and behavioral functioning. To date, there has been mixed findings on the profile of executive function deficits for high-functioning adults (IQ > 70) with ASD. A conceptual distinction is commonly made between "cold" and "hot" executive functions. Cold executive functions refer to mechanistic higher-order cognitive operations (e.g., working memory), whereas hot executive functions entail cognitive abilities supported by emotional awareness and social perception (e.g., social cognition). This study aimed to determine the independence of deficits in hot and cold executive functions for high-functioning adults with ASD. Forty-two adults with ASD (64% male, aged 18-66 years) and 40 age and gender matched controls were administered The Awareness of Social Inference Test (TASIT; emotion recognition and social inference), Letter Number Sequencing (working memory) and Hayling Sentence Completion Test (response initiation and suppression). Between-group analyses identified that the ASD group performed significantly worse than matched controls on all measures of cold and hot executive functions (d = 0.54 - 1.5). Hierarchical multiple regression analyses revealed that the ASD sample performed more poorly on emotion recognition and social inference tasks than matched controls after controlling for cold executive functions and employment status. The findings also indicated that the ability to recognize emotions and make social inferences was supported by working memory and response initiation and suppression processes. Overall, this study supports the distinction between hot and cold executive function impairments for adults with ASD. Moreover, it advances understanding of higher-order impairments underlying social interaction difficulties for this population which, in turn, may assist with diagnosis and inform intervention programs.
Particulate matter speciation profiles for light-duty gasoline vehicles in the United States.
Sonntag, Darrell B; Baldauf, Richard W; Yanca, Catherine A; Fulper, Carl R
2014-05-01
Representative profiles for particulate matter particles less than or equal to 2.5 microm (PM2.5) are developed from the Kansas City Light-Duty Vehicle Emissions Study for use in the US. Environmental Protection Agency (EPA) vehicle emission model, the Motor Vehicle Emission Simulator (MOVES), and for inclusion in the EPA SPECIATE database for speciation profiles. The profiles are compatible with the inputs of current photochemical air quality models, including the Community Multiscale Air Quality Aerosol Module Version 6 (AE6). The composition of light-duty gasoline PM2.5 emissions differs significantly between cold start and hot stabilized running emissions, and between older and newer vehicles, reflecting both impacts of aging/deterioration and changes in vehicle technology. Fleet-average PM2.5 profiles are estimated for cold start and hot stabilized running emission processes. Fleet-average profiles are calculated to include emissions from deteriorated high-emitting vehicles that are expected to continue to contribute disproportionately to the fleet-wide PM2.5 emissions into the future. The profiles are calculated using a weighted average of the PM2.5 composition according to the contribution of PM2.5 emissions from each class of vehicles in the on-road gasoline fleet in the Kansas City Metropolitan Statistical Area. The paper introduces methods to exclude insignificant measurements, correct for organic carbon positive artifact, and control for contamination from the testing infrastructure in developing speciation profiles. The uncertainty of the PM2.5 species fraction in each profile is quantified using sampling survey analysis methods. The primary use of the profiles is to develop PM2.5 emissions inventories for the United States, but the profiles may also be used in source apportionment, atmospheric modeling, and exposure assessment, and as a basis for light-duty gasoline emission profiles for countries with limited data. PM2.5 speciation profiles were developed from a large sample of light-duty gasoline vehicles tested in the Kansas City area. Separate PM2.5 profiles represent cold start and hot stabilized running emission processes to distinguish important differences in chemical composition. Statistical analysis was used to construct profiles that represent PM2.5 emissions from the U.S. vehicle fleet based on vehicles tested from the 2005 calendar year Kansas City metropolitan area. The profiles have been incorporated into the EPA MOVES emissions model, as well as the EPA SPECIATE database, to improve emission inventories and provide the PM2.5 chemical characterization needed by CMAQv5.0 for atmospheric chemistry modeling.
Thermo-chemical Ice Penetrator for Icy Moons
NASA Astrophysics Data System (ADS)
Arenberg, J. W.; Lee, G.; Harpole, G.; Zamel, J.; Sen, B.; Ross, F.; Retherford, K. D.
2016-12-01
The ability to place sensors or to take samples below the ice surface enables a wide variety of potential scientific investigations. Penetrating an ice cap can be accomplished via a mechanical drill, laser drill, kinetic impactor, or heated penetrator. This poster reports on the development of technology for the latter most option, namely a self-heated probe driven by an exothermic chemical reaction: a Thermo-chemical ice penetrator (TChIP). Our penetrator design employs a eutectic mix of alkali metals that produce an exothermic reaction upon contact with an icy surface. This reaction increases once the ice starts melting, so no external power is required. This technology is inspired by a classified Cold-War era program developed at Northrop Grumman for the US Navy. Terrestrial demonstration of this technology took place in the Arctic; however, this device cannot be considered high TRL for application at the icy moons of the solar system due to the environmental differences between Earth's Arctic and the icy moons. These differences demand a TChIP design specific to these cold, low mass, airless worlds. It is expected that this model of TChIP performance will be complex, incorporating all of the forces on the penetrator, gravity, the thermo-chemistry at the interface between penetrator and ice, and multi-phase heat and mass transport, and hydrodynamics. Our initial efforts are aimed at the development of a validated set of tools and simulations to predict the performance of the penetrator for both the environment found on these icy moons and for a terrestrial environment. The purpose of the inclusion of the terrestrial environment is to aid in model validation. Once developed and validated, our models will allow us to design penetrators for a specific scientific application on a specific body. This poster discusses the range of scientific investigations that are enabled by TChIP. We also introduce the development plan to advance TChIP to the point where it can be considered for infusion into a program.
Technology for a Thermo-chemical Ice Penetrator for Icy Moons
NASA Astrophysics Data System (ADS)
Arenberg, Jonathan; Harpole, George; Zamel, James; Sen, Bashwar; Lee, Greg; Ross, Floyd; Retherford, Kurt D.
2016-10-01
The ability to place sensors or to take samples below the ice surface enables a wide variety of potential scientific investigations. Penetrating an ice cap can be accomplished via a mechanical drill, laser drill, kinetic impactor, or heated penetrator. This poster reports on the development of technology for the latter most option, namely a self-heated probe driven by an exothermic chemical reaction: a Thermo-chemical ice penetrator (TChIP). Our penetrator design employs a eutectic mix of alkali metals that produce an exothermic reaction upon contact with an icy surface. This reaction increases once the ice starts melting, so no external power is required. This technology is inspired by a classified Cold-War era program developed at Northrop Grumman for the US Navy. Terrestrial demonstration of this technology took place in the Arctic; however, this device cannot be considered high TRL for application at the icy moons of the solar system due to the environmental differences between Earth's Arctic and the icy moons. These differences demand a TChIP design specific to these cold, low mass, airless worlds. It is expected that this model of TChIP performance will be complex, incorporating all of the forces on the penetrator, gravity, the thermo-chemistry at the interface between penetrator and ice, and multi-phase heat and mass transport, and hydrodynamics. Our initial efforts are aimed at the development of a validated set of tools and simulations to predict the performance of the penetrator for both the environment found on these icy moons and for a terrestrial environment. The purpose of the inclusion of the terrestrial environment is to aid in model validation. Once developed and validated, our models will allow us to design penetrators for a specific scientific application on a specific body. This poster discusses the range of scientific investigations that are enabled by TChIP. We also introduce the development plan to advance TChIP to the point where it can be considered for infusion into a program.
Chan, Tak W; Meloche, Eric; Kubsh, Joseph; Brezny, Rasto
2014-05-20
Black carbon (BC) mass and solid particle number emissions were obtained from two pairs of gasoline direct injection (GDI) vehicles and port fuel injection (PFI) vehicles over the U.S. Federal Test Procedure 75 (FTP-75) and US06 Supplemental Federal Test Procedure (US06) drive cycles on gasoline and 10% by volume blended ethanol (E10). BC solid particles were emitted mostly during cold-start from all GDI and PFI vehicles. The reduction in ambient temperature had significant impacts on BC mass and solid particle number emissions, but larger impacts were observed on the PFI vehicles than the GDI vehicles. Over the FTP-75 phase 1 (cold-start) drive cycle, the BC mass emissions from the two GDI vehicles at 0 °F (-18 °C) varied from 57 to 143 mg/mi, which was higher than the emissions at 72 °F (22 °C; 12-29 mg/mi) by a factor of 5. For the two PFI vehicles, the BC mass emissions over the FTP-75 phase 1 drive cycle at 0 °F varied from 111 to 162 mg/mi, higher by a factor of 44-72 when compared to the BC emissions of 2-4 mg/mi at 72 °F. The use of a gasoline particulate filter (GPF) reduced BC emissions from the selected GDI vehicle by 73-88% at various ambient temperatures over the FTP-75 phase 1 drive cycle. The ambient temperature had less of an impact on particle emissions for a warmed-up engine. Over the US06 drive cycle, the GPF reduced BC mass emissions from the GDI vehicle by 59-80% at various temperatures. E10 had limited impact on BC emissions from the selected GDI and PFI vehicles during hot-starts. E10 was found to reduce BC emissions from the GDI vehicle by 15% at standard temperature and by 75% at 19 °F (-7 °C).
Improving Efficiency of Aluminium Sacrificial Anode Using Cold Work Process
NASA Astrophysics Data System (ADS)
Asmara, Y. P.; Siregar, J. P.; Tezara, C.; Ann, Chang Tai
2016-02-01
Aluminium is one of the preferred materials to be used as sacrificial anode for carbon steel protection. The efficiency of these can be low due to the formation of oxide layer which passivate the anodes. Currently, to improve its efficiency, there are efforts using a new technique called surface modifications. The objective of this research is to study corrosion mechanism of aluminium sacrificial anode which has been processed by cold work. The cold works are applied by reducing the thickness of aluminium sacrificial anodes at 20% and 40% of thickness reduction. The cathodic protection experiments were performed by immersion of aluminium connected to carbon steel cylinder in 3% NaCl solutions. Visual inspections using SEM had been conducted during the experiments and corrosion rate data were taken in every week for 8 weeks of immersion time. Corrosion rate data were measured using weight loss and linear polarization technique (LPR). From the results, it is observed that cold worked aluminium sacrificial anode have a better corrosion performance. It shows higher corrosion rate and lower corrosion potential. The anodes also provided a long functional for sacrificial anode before it stop working. From SEM investigation, it is shown that cold works have changed the microstructure of anodes which is suspected in increasing corrosion rate and cause de-passivate of the surface anodes.
Seifert, John G; Frost, Jeremy; St Cyr, John A
2017-01-01
Breathing cold air can lead to bronchoconstriction and peripheral vasoconstriction, both of which could impact muscular performance by affecting metabolic demands during exercise. Successful solutions dealing with these physiological changes during exercise in the cold has been lacking; therefore, we investigated the influence of a heat and moisture exchange mask during exercise in the cold. There were three trial arms within this study: wearing the heat and moisture exchange mask during the rest periods in the cold, no-mask application during the rest periods in the cold, and a trial at room temperature (22°C). Eight subjects cycled in four 35 kJ sprint sessions with each session separated by 20 min rest period. Workload was 4% of body mass. Mean sprint times were faster with heat and moisture exchange mask and room temperature trial than cold, no-mask trial (133.8 ± 8.6, 134.9 ± 8.8, and 138.0 ± 8.4 s (p = 0.001)). Systolic blood pressure and mean arterial pressure were greater during the cold trial with no mask (15% and 13%, respectively), and heart rate was 10 bpm less during the third rest or recovery period during cold, no mask compared to the heat and moisture exchange mask and room temperature trials. Subjects demonstrated significant decreases in vital capacity and peak expiratory flow rate during the cold with no mask applied during the rest periods. These negative responses to cold exposure were alleviated by the use of a heat and moisture exchange mask worn during the rest intervals by minimizing cold-induced temperature stress on the respiratory system with subsequent maintenance of cardiovascular function.
Wong, Danny Ka-Ho; Tsoi, Ottilia; Huang, Fung-Yu; Seto, Wai-Kay; Fung, James; Lai, Ching-Lung
2014-01-01
Nucleoside/nucleotide analogue for the treatment of chronic hepatitis B virus (HBV) infection is hampered by the emergence of drug resistance mutations. Conventional PCR sequencing cannot detect minor variants of <20%. We developed a modified co-amplification at lower denaturation temperature-PCR (COLD-PCR) method for the detection of HBV minority drug resistance mutations. The critical denaturation temperature for COLD-PCR was determined to be 78°C. Sensitivity of COLD-PCR sequencing was determined using serially diluted plasmids containing mixed proportions of HBV reverse transcriptase (rt) wild-type and mutant sequences. Conventional PCR sequencing detected mutations only if they existed in ≥25%, whereas COLD-PCR sequencing detected mutations when they existed in 5 to 10% of the viral population. The performance of COLD-PCR was compared to conventional PCR sequencing and a line probe assay (LiPA) using 215 samples obtained from 136 lamivudine- or telbivudine-treated patients with virological breakthrough. Among these 215 samples, drug resistance mutations were detected in 155 (72%), 148 (69%), and 113 samples (53%) by LiPA, COLD-PCR, and conventional PCR sequencing, respectively. Nineteen (9%) samples had mutations detectable by COLD-PCR but not LiPA, while 26 (12%) samples had mutations detectable by LiPA but not COLD-PCR, indicating both methods were comparable (P = 0.371). COLD-PCR was more sensitive than conventional PCR sequencing. Thirty-five (16%) samples had mutations detectable by COLD-PCR but not conventional PCR sequencing, while none had mutations detected by conventional PCR sequencing but not COLD-PCR (P < 0.0001). COLD-PCR sequencing is a simple method which is comparable to LiPA and superior to conventional PCR sequencing in detecting minor lamivudine/telbivudine resistance mutations. PMID:24951803
On-board generation of a highly volatile starting fuel to reduce automobile cold-start emissions.
Ashford, Marcus D; Matthews, Ronald D
2006-09-15
The on-board distillation system (OBDS) was developed to extract, from gasoline, a high-volatility fuel for exclusive use during the starting and warm-up periods. The use of OBDS distillate fuel results in much improved mixture preparation, allowing combinations of air/fuel ratio and ignition timing that are not possible with gasoline, even with a fully warm engine. The volatility of the distillate is a function of the parent fuel volatility; however, the variability in distillate quality can be diminished via manipulation of the OBDS operating conditions. Thus, it is possible to develop aggressive starting calibrations that are relatively immune to variations in pump gasoline volatility. The key benefits provided bythe OBDS fuel relative to standard gasoline were found to be (1) improved mixture preparation allowing a 70% reduction of cranking fuel requirements, elimination of air-fuel mixture enrichment during the warm-up period, and significant extension of warm-up ignition timing retard; (2) a 57% decrease in catalyst light-off time, (3) emissions reductions over the FTP drive cycle of 81% for regulated hydrocarbons (NMOG); (4) emissions index (NMOG) approaching that of SULEV/PZEV vehicles; and (5) an apparent 1% increase in fuel economy over the FTP drive cycle.
Long pulse EBW start-up experiments in MAST
Shevchenko, V. F.; Baranov, Y. F.; Bigelow, T.; ...
2015-03-12
Start-up technique reported here relies on a double mode conversion (MC) for electron Bernstein wave (EBW) excitation. It consists of MC of the ordinary (O) mode, entering the plasma from the low field side of the tokamak, into the extraordinary (X) mode at a mirror-polarizer located at the high field side. The X mode propagates back to the plasma, passes through electron cyclotron resonance (ECR) and experiences a subsequent X to EBW MC near the upper hybrid resonance (UHR). Finally the excited EBW mode is totally absorbed at the Doppler shifted ECR. The absorption of EBW remains high even inmore » cold rarefied plasmas. Furthermore, EBW can generate significant plasma current giving the prospect of a fully solenoid-free plasma start-up. First experiments using this scheme were carried out on MAST [1]. Plasma currents up to 33 kA have been achieved using 28 GHz 100kW 90ms RF pulses. Recently experimental results were extended to longer RF pulses showing further increase of plasma currents generated by RF power alone. A record current of 73kA has been achieved with 450ms RF pulse of similar power. The current drive enhancement was mainly achieved due to RF pulse extension and further optimisation of the start-up scenario.« less
Long pulse EBW start-up experiments in MAST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shevchenko, V. F.; Baranov, Y. F.; Bigelow, T.
Start-up technique reported here relies on a double mode conversion (MC) for electron Bernstein wave (EBW) excitation. It consists of MC of the ordinary (O) mode, entering the plasma from the low field side of the tokamak, into the extraordinary (X) mode at a mirror-polarizer located at the high field side. The X mode propagates back to the plasma, passes through electron cyclotron resonance (ECR) and experiences a subsequent X to EBW MC near the upper hybrid resonance (UHR). Finally the excited EBW mode is totally absorbed at the Doppler shifted ECR. The absorption of EBW remains high even inmore » cold rarefied plasmas. Furthermore, EBW can generate significant plasma current giving the prospect of a fully solenoid-free plasma start-up. First experiments using this scheme were carried out on MAST [1]. Plasma currents up to 33 kA have been achieved using 28 GHz 100kW 90ms RF pulses. Recently experimental results were extended to longer RF pulses showing further increase of plasma currents generated by RF power alone. A record current of 73kA has been achieved with 450ms RF pulse of similar power. The current drive enhancement was mainly achieved due to RF pulse extension and further optimisation of the start-up scenario.« less
Long Pulse EBW Start-up Experiments in MAST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shevchenko, V. F.; Bigelow, Tim S; Caughman, J. B. O.
Start-up technique reported here relies on a double mode conversion (MC) for electron Bernstein wave (EBW) excitation. It consists of MC of the ordinary (0) mode, entering the plasma from the low field side of the tokamak, into the extraordinary (X) mode at a mirror-polarizer located at the high field side. The X mode propagates back to the plasma, passes through electron cyclotron resonance (ECR) and experiences a subsequent X to EBW MC near the upper hybrid resonance (UHR). Finally the excited EBW mode is totally absorbed at the Doppler shifted ECR. The absorption of EBW remains high even inmore » cold rarefied plasmas. Furthermore, EBW can generate significant plasma current giving the prospect of a fully solenoid-free plasma start-up. First experiments using this scheme were carried out on MAST [1]. Plasma currents up to 33 kA have been achieved using 28 GHz 100kW 90ms RF pulses. Recently experimental results were extended to longer RF pulses showing further increase of plasma currents generated by RF power alone. A record current of 73kA has been achieved with 450ms RF pulse of similar power. The current drive enhancement was mainly achieved due to RF pulse extension and further optimisation of the start-up scenario.« less
Catalá, Rafael; López-Cobollo, Rosa; Mar Castellano, M.; Angosto, Trinidad; Alonso, José M.; Ecker, Joseph R.; Salinas, Julio
2014-01-01
In plants, the expression of 14-3-3 genes reacts to various adverse environmental conditions, including cold, high salt, and drought. Although these results suggest that 14-3-3 proteins have the potential to regulate plant responses to abiotic stresses, their role in such responses remains poorly understood. Previously, we showed that the RARE COLD INDUCIBLE 1A (RCI1A) gene encodes the 14-3-3 psi isoform. Here, we present genetic and molecular evidence implicating RCI1A in the response to low temperature. Our results demonstrate that RCI1A functions as a negative regulator of constitutive freezing tolerance and cold acclimation in Arabidopsis thaliana by controlling cold-induced gene expression. Interestingly, this control is partially performed through an ethylene (ET)-dependent pathway involving physical interaction with different ACC SYNTHASE (ACS) isoforms and a decreased ACS stability. We show that, consequently, RCI1A restrains ET biosynthesis, contributing to establish adequate levels of this hormone in Arabidopsis under both standard and low-temperature conditions. We further show that these levels are required to promote proper cold-induced gene expression and freezing tolerance before and after cold acclimation. All these data indicate that RCI1A connects the low-temperature response with ET biosynthesis to modulate constitutive freezing tolerance and cold acclimation in Arabidopsis. PMID:25122152
NASA Astrophysics Data System (ADS)
Gang, Liu; Meihui, Qu; Guolin, Feng; Qucheng, Chu; Jing, Cao; Jie, Yang; Ling, Cao; Yao, Feng
2018-03-01
This paper introduces three quantitative indicators to conduct research for characterizing Northeast China cold vortex persistence activity: cold vortex persistence, generalized "cold vortex," and cold vortex precipitation. As discussed in the first part of paper, a hindcast is performed by multiple regressions using Northeast China precipitation from 2012 to 2014 combination with the previous winter 144 air-sea system factors. The results show that the mentioned three cold vortex index series can reflect the spatial and temporal distributions of observational precipitation in 2012-2014 and obtain results. The cold vortex factors are then added to the Forecast System on Dynamical and Analogy Skills (FODAS) to carry out dynamic statistical hindcast of precipitation in Northeast China from 2003 to 2012. Based on the characteristics and significance of each index, precipitation hindcast is carried out for Northeast China in May, June, July, August, May-June, and July-August. It turns out that the Northeast Cold Vortex Index Series, as defined in this paper, can make positive corrections to the FODAS forecast system, and most of the index correction results are higher than the system's own correction value. This study provides quantitative index products and supplies a solid technical foundation and support for monthly precipitation forecast in Northeast China.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Hung-Pin; Chen, Yen-Chun; Chen, Delphic
2014-08-15
In this study, the evolution of the recrystallization texture and microstructure was investigated after annealing of 50% and 90% cold-rolled FePd alloy at 530 °C. The FePd alloy was produced by vacuum arc melting in an atmosphere of 97% Ar and 3% H{sub 2}. The specimens were cold rolled to achieve 50% and 90% reduction in thickness. Electron backscatter diffraction measurements were performed on the rolling direction–normal direction section. With increased deformation from 50% to 90%, recrystallized texture transition occurs. For the 50% cold-rolled alloy, the preferred orientation is (0 1 0) [11 0 1], which is close to themore » cubic orientation after 400 h of annealing. For the 90% cold-rolled alloy, the orientation changes to (0 5 4) [22–4 5] after 16 h of annealing. - Highlights: • Texture and microstructure in cold-rolled FePd alloy was investigated during annealing using EBSD. • The recrystallized texture of 50% cold-rolled FePd is (0 1 0) [11 0 1] at 530 °C for 400 hours. • The recrystallized texture of 90% cold-rolled FePd is changed to (0 5 4) [22–4 5] at 530 °C after 16 hours.« less
Goel, V; Lovlin, R; Barton, R; Lyon, M R; Bauer, R; Lee, T D G; Basu, T K
2004-02-01
Recently, echinacea has regained popularity as one of the treatments chosen most commonly by consumers with the expectation that it will reduce the severity and duration of the common cold. However, the results from a limited number of clinical trials for this application have thus far been inconclusive. This incongruity may be the result of investigators utilizing poorly standardized echinacea products, likely devoid of sufficient quantities of active constituents necessary to exert a definitive clinical effect. Therefore, a formulation containing alkamides, cichoric acid, and polysaccharides at concentrations of 0.25, 2.5, and 25 mg/mL, respectively, was prepared from freshly harvested Echinacea purpurea plants (commercially available as Echinilin, Natural Factors Nutritional Products, Inc., Vancouver, BC, Canada). The objective of this study was to test the efficacy of this highly standardized formulation in reducing the severity and duration of symptoms of a naturally acquired common cold. In a randomized, double-blind, placebo-controlled trial, 282 subjects aged 18-65 years with a history of two or more colds in the previous year, but otherwise in good health, were recruited. The subjects were randomized to receive either echinacea or placebo. They were instructed to start the echinacea or placebo at the onset of the first symptom related to a cold, consuming 10 doses the first day and four doses per day on subsequent days for 7 days. Severity of symptoms (10-point scale: 0, minimum; 9, maximum) and dosing were recorded daily. A nurse examined the subjects on the mornings of days 3 and 8 of their cold. A total of 128 subjects contracted a common cold (59 echinacea, 69 placebo). The total daily symptom scores were found to be 23.1% lower in the echinacea group than in placebo in those who followed all elements of the study protocol (P<0.01). Throughout the treatment period, the response rate to treatments was greater in the echinacea group. A few adverse event profiles were observed in both groups. Early intervention with a standardized formulation of echinacea resulted in reduced symptom severity in subjects with naturally acquired upper respiratory tract infection. Further studies with larger patient populations appear to be warranted.
NASA Astrophysics Data System (ADS)
Ilie, C. A.; Visa, I.; Duta, A.
2016-08-01
The EU legal frame imposes the Nearly Zero Energy Buildings (nZEB) status to any new public building starting with January 1st, 2019 and for any other new building starting with 2021. Basically, nZEB represents a Low Energy Building (LEB) that covers more than half of the energy demand by using renewable energy systems installed on or close to it. Thus, two steps have to be followed in developing nZEB: (1) reaching the LEB status through state- of-the art architectural and construction solutions (for the new buildings) or through refurbishing for the already existent buildings, followed by (2) implementing renewables; in Romania, over 65% of the energy demand in a building is directly linked to heating, domestic hot water (DHW), and - in certain areas - for cooling. Thus, effort should be directed to reduce the thermal energy demand to be further covered by using clean and affordable systems: solar- thermal systems, heat pumps, biomass, etc. or their hybrid combinations. Obviously this demand is influenced by the onsite climatic profile and by the building performance. An almost worst case scenario is approached in the paper, considering a community implemented in a mountain area, with cold and long winters and mild summers (Odorheiul Secuiesc city, Harghita county, Romania). Three representative types of buildings are analysed: multi-family households (in blocks of flats), single-family houses and administrative buildings. For the first two types, old and refurbished buildings were comparatively discussed.
NASA Astrophysics Data System (ADS)
Régis, J.-M.; Jolie, J.; Mach, H.; Simpson, G. S.; Blazhev, A.; Pascovici, G.; Pfeiffer, M.; Rudigier, M.; Saed-Samii, N.; Warr, N.; Blanc, A.; de France, G.; Jentschel, M.; Köster, U.; Mutti, P.; Soldner, T.; Ur, C. A.; Urban, W.; Bruce, A. M.; Drouet, F.; Fraile, L. M.; Ilieva, S.; Korten, W.; Kröll, T.; Lalkovski, S.; Mărginean, S.; Paziy, V.; Podolyák, Zs.; Regan, P. H.; Stezowski, O.; Vancraeyenest, A.
2015-05-01
A novel method for direct electronic "fast-timing" lifetime measurements of nuclear excited states via γ-γ coincidences using an array equipped with N very fast high-resolution LaBr3(Ce) scintillator detectors is presented. The generalized centroid difference method provides two independent "start" and "stop" time spectra obtained without any correction by a superposition of the N(N - 1)/2 calibrated γ-γ time difference spectra of the N detector fast-timing system. The two fast-timing array time spectra correspond to a forward and reverse gating of a specific γ-γ cascade and the centroid difference as the time shift between the centroids of the two time spectra provides a picosecond-sensitive mirror-symmetric observable of the set-up. The energydependent mean prompt response difference between the start and stop events is calibrated and used as a single correction for lifetime determination. These combined fast-timing array mean γ-γ zero-time responses can be determined for 40 keV < Eγ < 1.4 MeV with a precision better than 10 ps using a 152Eu γ-ray source. The new method is described with examples of (n,γ) and (n,f,γ) experiments performed at the intense cold-neutron beam facility PF1B of the Institut Laue-Langevin in Grenoble, France, using 16 LaBr3(Ce) detectors within the EXILL&FATIMA campaign in 2013. The results are discussed with respect to possible systematic errors induced by background contributions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bacchiani, M.; Medich, C.; Rigamonti, M.
1995-09-01
The SPES-2 is a full height, full pressure experimental test facility reproducing the Westinghouse AP600 reactor with a scaling factor of 1/395. The experimental plant, designed and operated by SIET in Piacenza, consists of a full simulation of the AP600 primary core cooling system including all the passive and active safety systems. In 1992, Westinghouse, in cooperation with ENEL (Ente Nazionale per l` Energia Elettrica), ENEA (Enter per le numove Technlogie, l` Energia e l` Ambient), Siet (Societa Informazioni Esperienze Termoidraulich) and ANSALDO developed an experimental program to test the integrated behaviour of the AP600 passive safety systems. The SPES-2more » test matrix, concluded in November 1994, has examined the AP600 passive safety system response for a range of small break LOCAs at different locations on the primary system and on the passive system lines; single steam generator tube ruptures with passive and active safety systems and a main steam line break transient to demonstrate the boration capability of passive safety systems for rapid cooldown. Each of the tests has provided detailed experimental results for verification of the capability of the analysis methods to predict the integrated passive safety system behaviour. Cold and hot shakedown tests have been performed on the facility to check the characteristics of the plant before starting the experimental campaign. The paper first presents a description of the SPES-2 test facility then the main results of S01007 test {open_quotes}2{close_quotes} Cold Leg (CL) to Core Make-up Tank (CMT) pressure balance line break{close_quotes} are reported and compared with predictions performed using RELAP5/mod3/80 obtained by ANSALDO through agreement with U.S.N.R.C. (U.S. Nuclear Regulatory Commission). The SPES-2 nodalization and all the calculations here presented were performed by ANSALDO and sponsored by ENEL as a part of pre-test predictions for SPES-2.« less