Amanidaz, Nazak; Zafarzadeh, Ali; Mahvi, Amir Hossein
2015-12-01
This study investigated the interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in water supply networks. This study was conducted during 2013 on water supply distribution network in Aq Qala City, Golestan Province, Northern Iran and standard methods were applied for microbiological analysis. The surface method was applied to test the heterotrophic bacteria and MPN method was used for coliform, fecal coliform and fecal streptococci bacteria measurements. In 114 samples, heterotrophic bacteria count were over 500 CFU/ml, which the amount of fecal coliform, coliform, and fecal streptococci were 8, 32, and 20 CFU/100 ml, respectively. However, in the other 242 samples, with heterotrophic bacteria count being less than 500 CFU/ml, the amount of fecal coliform, coliform, and fecal streptococci was 7, 23, and 11 CFU/100ml, respectively. The relationship between heterotrophic bacteria, coliforms and fecal streptococci was highly significant (P<0.05). We observed the concentration of coliforms, fecal streptococci bacteria being high, whenever the concentration of heterotrophic bacteria in the water network systems was high. Interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in the Aq Qala City water supply networks was not notable. It can be due to high concentrations of organic carbon, bio-films and nutrients, which are necessary for growth, and survival of all microorganisms.
AMANIDAZ, Nazak; ZAFARZADEH, Ali; MAHVI, Amir Hossein
2015-01-01
Background: This study investigated the interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in water supply networks. Methods: This study was conducted during 2013 on water supply distribution network in Aq Qala City, Golestan Province, Northern Iran and standard methods were applied for microbiological analysis. The surface method was applied to test the heterotrophic bacteria and MPN method was used for coliform, fecal coliform and fecal streptococci bacteria measurements. Results: In 114 samples, heterotrophic bacteria count were over 500 CFU/ml, which the amount of fecal coliform, coliform, and fecal streptococci were 8, 32, and 20 CFU/100 ml, respectively. However, in the other 242 samples, with heterotrophic bacteria count being less than 500 CFU/ml, the amount of fecal coliform, coliform, and fecal streptococci was 7, 23, and 11 CFU/100ml, respectively. The relationship between heterotrophic bacteria, coliforms and fecal streptococci was highly significant (P<0.05). We observed the concentration of coliforms, fecal streptococci bacteria being high, whenever the concentration of heterotrophic bacteria in the water network systems was high. Conclusion: Interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in the Aq Qala City water supply networks was not notable. It can be due to high concentrations of organic carbon, bio-films and nutrients, which are necessary for growth, and survival of all microorganisms. PMID:26811820
Influence of Coliform Source on Evaluation of Membrane Filters
Brodsky, M. H.; Schiemann, D. A.
1975-01-01
Four brands of membrane filters were examined for total and fecal coliform recovery performance by two experimental approaches. Using diluted EC broth cultures of water samples, Johns-Manville filters were superior to Sartorius filters for fecal coliform but equivalent for total coliform recovery. Using river water samples, Johns-Manville filters were superior to Sartorius filters for total coliform but equivalent for fecal coliform recovery. No differences were observed between Johns-Manville and Millipore or Millipore and Sartorius filters for total or fecal coliform recoveries using either approach, nor was any difference observed between Millipore and Gelman filters for fecal coliform recovery from river water samples. These results indicate that the source of the coliform bacteria has an important influence on the conclusions of membrane filter evaluation studies. PMID:1106318
40 CFR 412.2 - General definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
....23. (c) Fecal coliform means the bacterial count (Parameter 1) at 40 CFR 136.3 in Table 1A, which... Table 1A at 40 CFR 136.3 are defined as follows: (1) Fecal coliform means fecal coliform bacteria. (2) Total coliform means all coliform bacteria. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-21
... Total Coliform Total Coliform 9221 A, B, C..... 9221 A, B, C..... Fermentation Technique. Total Coliform... Methodology category Method SM 22nd Edition \\28\\ Total Coliforms Lactose Fermentation Standard Total 9221 B.1, B.2 Methods. Coliform Fermentation Technique. Enzyme Substrate Colilert[supreg].... 9223 B Methods...
Full-scale studies of factors related to coliform regrowth in drinking water.
LeChevallier, M W; Welch, N J; Smith, D B
1996-07-01
An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem.
Full-scale studies of factors related to coliform regrowth in drinking water.
LeChevallier, M W; Welch, N J; Smith, D B
1996-01-01
An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem. PMID:8779557
Liu, Wen-Cheng; Chan, Wen-Ting
2015-12-01
Climate change is one of the key factors affecting the future microbiological water quality in rivers and tidal estuaries. A coupled 3D hydrodynamic and fecal coliform transport model was developed and applied to the Danshuei River estuarine system for predicting the influences of climate change on microbiological water quality. The hydrodynamic and fecal coliform model was validated using observational salinity and fecal coliform distributions. According to the analyses of the statistical error, predictions of the salinity and the fecal coliform concentration from the model simulation quantitatively agreed with the observed data. The validated model was then applied to predict the fecal coliform contamination as a result of climate change, including the change of freshwater discharge and the sea level rise. We found that the reduction of freshwater discharge under climate change scenarios resulted in an increase in the fecal coliform concentration. The sea level rise would decrease fecal coliform distributions because both the water level and the water volume increased. A reduction in freshwater discharge has a negative impact on the fecal coliform concentration, whereas a rising sea level has a positive influence on the fecal coliform contamination. An appropriate strategy for the effective microbiological management in tidal estuaries is required to reveal the persistent trends of climate in the future.
The Evolving Role of Coliforms As Indicators of Unhygienic Processing Conditions in Dairy Foods.
Martin, Nicole H; Trmčić, Aljoša; Hsieh, Tsung-Han; Boor, Kathryn J; Wiedmann, Martin
2016-01-01
Testing for coliforms has a long history in the dairy industry and has helped to identify raw milk and dairy products that may have been exposed to unsanitary conditions. Coliform standards are included in a number of regulatory documents (e.g., the U.S. Food and Drug Administration's Grade "A" Pasteurized Milk Ordinance). As a consequence, detection above a threshold of members of this method-defined, but diverse, group of bacteria can result in a wide range of regulatory outcomes. Coliforms are defined as aerobic or facultatively anaerobic, Gram negative, non-sporeforming rods capable of fermenting lactose to produce gas and acid within 48 h at 32-35°C; 19 genera currently include at least some strains that represent coliforms. Most bacterial genera that comprise the coliform group (e.g., Escherichia , Klebsiella , and Serratia ) are within the family Enterobacteriaceae, while at least one genus with strains recognized as coliforms, Aeromonas , is in the family Aeromonadaceae. The presence of coliforms has long been thought to indicate fecal contamination, however, recent discoveries regarding this diverse group of bacteria indicates that only a fraction are fecal in origin, while the majority are environmental contaminants. In the US dairy industry in particular, testing for coliforms as indicators of unsanitary conditions and post-processing contamination is widespread. While coliforms are easily and rapidly detected, and are not found in pasteurized dairy products that have not been exposed to post-processing contamination, advances in knowledge of bacterial populations most commonly associated with post-processing contamination in dairy foods has led to questions regarding the utility of coliforms as indicators of unsanitary conditions for dairy products. For example, Pseudomonas spp. frequently contaminate dairy products after pasteurization, yet they are not detected by coliform tests. This review will address the role that coliforms play in raw and finished dairy products, their sources and the future of this diverse group as indicator organisms in dairy products.
The Evolving Role of Coliforms As Indicators of Unhygienic Processing Conditions in Dairy Foods
Martin, Nicole H.; Trmčić, Aljoša; Hsieh, Tsung-Han; Boor, Kathryn J.; Wiedmann, Martin
2016-01-01
Testing for coliforms has a long history in the dairy industry and has helped to identify raw milk and dairy products that may have been exposed to unsanitary conditions. Coliform standards are included in a number of regulatory documents (e.g., the U.S. Food and Drug Administration’s Grade “A” Pasteurized Milk Ordinance). As a consequence, detection above a threshold of members of this method-defined, but diverse, group of bacteria can result in a wide range of regulatory outcomes. Coliforms are defined as aerobic or facultatively anaerobic, Gram negative, non-sporeforming rods capable of fermenting lactose to produce gas and acid within 48 h at 32–35°C; 19 genera currently include at least some strains that represent coliforms. Most bacterial genera that comprise the coliform group (e.g., Escherichia, Klebsiella, and Serratia) are within the family Enterobacteriaceae, while at least one genus with strains recognized as coliforms, Aeromonas, is in the family Aeromonadaceae. The presence of coliforms has long been thought to indicate fecal contamination, however, recent discoveries regarding this diverse group of bacteria indicates that only a fraction are fecal in origin, while the majority are environmental contaminants. In the US dairy industry in particular, testing for coliforms as indicators of unsanitary conditions and post-processing contamination is widespread. While coliforms are easily and rapidly detected, and are not found in pasteurized dairy products that have not been exposed to post-processing contamination, advances in knowledge of bacterial populations most commonly associated with post-processing contamination in dairy foods has led to questions regarding the utility of coliforms as indicators of unsanitary conditions for dairy products. For example, Pseudomonas spp. frequently contaminate dairy products after pasteurization, yet they are not detected by coliform tests. This review will address the role that coliforms play in raw and finished dairy products, their sources and the future of this diverse group as indicator organisms in dairy products. PMID:27746769
Escherichia coli, total coliform, and fecal coliform data were collected from two wastewater treatment facilities, a subsurface constructed wetlands, and the receiving stream. Results are presented from individual wastewater treatment process streams, final effluent and river sit...
Examination and characterization of distribution system biofilms.
LeChevallier, M W; Babcock, T M; Lee, R G
1987-01-01
Investigations concerning the role of distribution system biofilms on water quality were conducted at a drinking water utility in New Jersey. The utility experienced long-term bacteriological problems in the distribution system, while treatment plant effluents were uniformly negative for coliform bacteria. Results of a monitoring program showed increased coliform levels as the water moved from the treatment plant through the distribution system. Increased coliform densities could not be accounted for by growth of the cells in the water column alone. Identification of coliform bacteria showed that species diversity increased as water flowed through the study area. All materials in the distribution system had high densities of heterotrophic plate count bacteria, while high levels of coliforms were detected only in iron tubercles. Coliform bacteria with the same biochemical profile were found both in distribution system biofilms and in the water column. Assimilable organic carbon determinations showed that carbon levels declined as water flowed through the study area. Maintenance of a 1.0-mg/liter free chlorine residual was insufficient to control coliform occurrences. Flushing and pigging the study area was not an effective control for coliform occurrences in that section. Because coliform bacteria growing in distribution system biofilms may mask the presence of indicator organisms resulting from a true breakdown of treatment barriers, the report recommends that efforts continue to find methods to control growth of coliform bacteria in pipeline biofilms. Images PMID:3435140
Moyer, Douglas; Hyer, Kenneth
2003-01-01
Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Blacks Run, in Rockingham County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Accotink Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Blacks Run. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Blacks Run watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Blacks Run. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Blacks Run. The calibrated streamflow model simulated observed streamflow characteristics with respect to total annual runoff, seasonal runoff, average daily streamflow, and hourly stormflow. The calibrated fecal coliform model simulated the patterns and range of observed fecal coliform bacteria concentrations. Observed fecal coliform bacteria concentrations during low-flow periods ranged from 40 to 7,000 colonies per 100 milliliters, and peak concentrations during storm-flow periods ranged from 33,000 to 260,000 colonies per 100 milliliters. Simulated source-specific contributions of fecal coliform bacteria to instream load were matched to the observed contributions from the dominant sources, which were cats, cattle, deer, dogs, ducks, geese, horses, humans, muskrats, poultry, raccoons, and sheep. According to model results, a 95-percent reduction in the current fecal coliform load delivered from the watershed to Blacks Run would result in compliance with the designated water-quality goals and associated TMDL.
Moyer, Douglas; Hyer, Kenneth
2003-01-01
Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Accotink Creek, in Fairfax County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Accotink Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Accotink Creek. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Accotink Creek watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Accotink Creek. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Accotink Creek. The calibrated streamflow model simulated observed streamflow characteristics with respect to total annual runoff, seasonal runoff, average daily streamflow, and hourly stormflow. The calibrated fecal coliform model simulated the patterns and range of observed fecal coliform bacteria concentrations. Observed fecal coliform bacteria concentrations during low-flow periods ranged from 25 to 800 colonies per 100 milliliters, and peak concentrations during storm-flow periods ranged from 19,000 to 340,000 colonies per 100 milliliters. Simulated source-specific contributions of fecal coliform bacteria to instream load were matched to the observed contributions from the dominant sources, which were cats, deer, dogs, ducks, geese, humans, muskrats, and raccoons. According to model results, an 89-percent reduction in the current fecal coliform load delivered from the watershed to Accotink Creek would result in compliance with the designated water-quality goals and associated TMDL.
Moyer, Douglas; Hyer, Kenneth
2003-01-01
Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Christians Creek, in Augusta County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Christians Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Christians Creek. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Christians Creek watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Christians Creek. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Christians Creek. The calibrated streamflow model simulated observed streamflow characteristics with respect to total annual runoff, seasonal runoff, average daily streamflow, and hourly stormflow. The calibrated fecal coliform model simulated the patterns and range of observed fecal coliform bacteria concentrations. Observed fecal coliform bacteria concentrations during low-flow periods ranged from 40 to 2,000 colonies per 100 milliliters, and peak concentrations during stormflow periods ranged from 23,000 to 730,000 colonies per 100 milliliters. Additionally, fecal coliform bacteria concentrations were generally higher upstream and lower downstream. Simulated source-specific contributions of fecal coliform bacteria to instream load were matched to the observed contributions from the dominant sources, which were beaver, cats, cattle, deer, dogs, ducks, geese, horses, humans, muskrats, poultry, raccoons, and sheep. According to model results, a 96-percent reduction in the current fecal coliform load delivered from the watershed to Christians Creek would result in compliance with the designated water-quality goals and associated TMDL.
33 CFR 159.127 - Safety coliform count: Recirculating devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety coliform count....127 Safety coliform count: Recirculating devices. Thirty-eight of forty samples of flush fluid from a recirculating device must have less than 240 fecal coliform bacteria per 100 milliliters. These samples must be...
Evaluation of Porcelain Cup Soil Water Samplers for Bacteriological Sampling1
Dazzo, Frank B.; Rothwell, Donald F.
1974-01-01
The validity of obtaining soil water for fecal coliform analyses by porcelain cup soil water samplers was examined. Numbers from samples of manure slurry drawn through porcelain cups were reduced 100- to 10,000,000-fold compared to numbers obtained from the external manure slurry, and 65% of the cups yielded coliform-free samples. Fecal coliforms adsorbed to cups apparently were released, thus influencing the counts of subsequent samples. Fecal coliforms persisted in soil water samplers buried in soil and thus could significantly influence the coliform counts of water samples obtained a month later. These studies indicate that porcelain cup soil water samplers do not yield valid water samples for fecal coliform analyses. Images PMID:16349998
Gas Chromatographic Presumptive Test for Coliform Bacteria in Water
Newman, Judith S.; O'Brien, R. T.
1975-01-01
A gas chromatographic procedure which shows promise as a presumptive test for coliform bacteria in water is described. Total coliform bacteria concentrations were determined from the incubation times at 37 C required for ethanol to be produced. Fecal coliform densities were determined in a similar manner at 44.5 C. The culture medium was filter sterilized M-9 salts supplemented with 1% lactose, 0.1% Casamino Acids, and 0.1% yeast extract. Best results were obtained when the initial total coliform concentrations were 5 per ml or higher and when fecal coliform concentrations were 50 per ml or higher. Minimum detection times at these concentrations were 9 and 12 h, respectively. PMID:1103731
Effect of dredge spoil deposition on fecal coliform counts in sediments at a disposal site.
Babinchak, J A; Graikoski, J T; Dudley, S; Nitkowski, M F
1977-01-01
The most-probable-number of fecal coliforms in sediments was monitored at the New London dump site in Long Island Sound during the deposition of dredge spoil from the Thames River. Although the geometric mean for fecal coliforms at five stations in the river was 14,000/100 ml before dredging commenced, the deposition of this material did not increase the incidence of fecal coliforms at 17 spoil stations and 13 control stations in the disposal and surrounding areas. Fecal coliforms appear to occur only in the surface sediment material and are diluted by the subsurface material during the dredging operation. Fecal coliform analyses of bottom waters during high and low tides indicated that the flow of water from the Thames River played a major role in determining the most-probable-number of fecal coliforms in the sediments at the disposal site. PMID:329761
40 CFR 142.16 - Special primacy requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... coliform or E. coli testing on a total coliform-positive sample)—A description of how the State will determine whether it is appropriate to waive fecal coliform or E. coli testing on a total coliform-positive... where allowed in State programs. (1) Approve an alternative to the E. coli levels that trigger...
Iranpour, Reza; Cox, Huub H J
2006-09-01
The U.S. Environmental Protection Agency (U.S. EPA) Part 503 Biosolids Rule requires the fecal coliform (indicator) or Salmonella species (pathogen) density requirements for Class A biosolids to be met at the last point of plant control (truck-loading facility and/or farm for land application). The three Southern Californian wastewater treatment plants in this study produced biosolids by thermophilic anaerobic digestion and all met the Class A limits for both fecal coliforms and Salmonella sp. in the digester outflow biosolids. At two plants, however, a recurrence of fecal coliforms was observed in postdigestion biosolids, which caused exceedance of the Class A limit for fecal coliforms at the truck-loading facility and farm for land application. Comparison of observations at the three plants and further laboratory tests indicated that the recurrence of fecal coliforms can possibly be related to the following combination of factors: (1) incomplete destruction of fecal coliforms during thermophilic anaerobic digestion, (2) contamination of Class A biosolids with fecal coliforms from external sources during postdigestion, (3) a large drop of the postdigestion biosolids temperature to below the maximum for fecal coliform growth, (4) an unknown effect of biosolids dewatering in centrifuges. At Hyperion Treatment Plant (City of Los Angeles, California), fecal coliform recurrence could be prevented by the following: (1) complete conversion to thermophilic operation to exclude contamination by mesophilically digested biosolids and (2) insulation and electrical heat-tracing of postdigestion train for maintaining a high biosolids temperature in postdigestion.
Teramura, H; Sota, K; Iwasaki, M; Ogihara, H
2017-07-01
Sanita-kun™ CC (coliform count) and EC (Escherichia coli/coliform count), sheet quantitative culture systems which can avoid chromogenic interference by lactase in food, were evaluated in comparison with conventional methods for these bacteria. Based on the results of inclusivity and exclusivity studies using 77 micro-organisms, sensitivity and specificity of both Sanita-kun™ met the criteria for ISO 16140. Both media were compared with deoxycholate agar, violet red bile agar, Merck Chromocult™ coliform agar (CCA), 3M Petrifilm™ CC and EC (PEC) and 3-tube MPN, as reference methods, in 100 naturally contaminated food samples. The correlation coefficients of both Sanita-kun™ for coliform detection were more than 0·95 for all comparisons. For E. coli detection, Sanita-kun™ EC was compared with CCA, PEC and MPN in 100 artificially contaminated food samples. The correlation coefficients for E. coli detection of Sanita-kun™ EC were more than 0·95 for all comparisons. There were no significant differences in all comparisons when conducting a one-way analysis of variance (anova). Both Sanita-kun™ significantly inhibited colour interference by lactase when inhibition of enzymatic staining was assessed using 40 natural cheese samples spiked with coliform. Our results demonstrated Sanita-kun™ CC and EC are suitable alternatives for the enumeration of coliforms and E. coli/coliforms, respectively, in a variety of foods, and specifically in fermented foods. Current chromogenic media for coliforms and Escherichia coli/coliforms have enzymatic coloration due to breaking down of chromogenic substrates by food lactase. The novel sheet culture media which have film layer to avoid coloration by food lactase have been developed for enumeration of coliforms and E. coli/coliforms respectively. In this study, we demonstrated these media had comparable performance with reference methods and less interference by food lactase. These media have a possibility not only to be useful alternatives but also to contribute for accurate enumeration of these bacteria in a variety of foods, and specifically in fermented foods. © 2017 The Society for Applied Microbiology.
Aulenbach, Brent T.
2010-01-01
Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.
Drinking water regulations under the Final Coliform Rule require that total coliform-positive drinking water samples be examined for the presence of Escherichia coli or fecal coliforms. The current U.S. Environmental Protection Agency-approved membrane filter (MF) method for E. c...
An Environmental Health Assessment: Fecal Coliform Contamination in San Francisco Waterbodies
NASA Astrophysics Data System (ADS)
Devillier, K. N.; Devine, M.; Negrete, R.; Rawley, A. L.; Neiss, J.
2007-12-01
Fecal coliform is a group of bacteria that exists in the digestive system and excrement of warm-blooded animals. It enters aquatic environments through fecal contamination of water. In the urban environment, contamination can occur not only by direct input from warm-blooded animals but also from storm water run-off and municipal sewer overflow. Fecal coliform itself does not cause disease but it is an indicator of the presence of pathogens that exist in the wastes of humans and animals that are a hazard to human health. We examined 12 locations in San Francisco for fecal coliform and recorded the types of human contact with water at each location. We found low levels of coliform in areas open to the San Francisco Bay and Pacific Ocean and high levels of coliform in inland lakes and ponds. Using Environmental Protection Agency guidelines for fecal coliform concentrations, we found all sites at acceptable levels for the recreational and human activities we observed.
Evans, T M; LeChevallier, M W; Waarvick, C E; Seidler, R J
1981-01-01
The species of total coliform bacteria isolated from drinking water and untreated surface water by the membrane filter (MF), the standard most-probable-number (S-MPN), and modified most-probable-number (M-MPN) techniques were compared. Each coliform detection technique selected for a different profile of coliform species from both types of water samples. The MF technique indicated that Citrobacter freundii was the most common coliform species in water samples. However, the fermentation tube techniques displayed selectivity towards the isolation of Escherichia coli and Klebsiella. The M-MPN technique selected for more C. freundii and Enterobacter spp. from untreated surface water samples and for more Enterobacter and Klebsiella spp. from drinking water samples than did the S-MPN technique. The lack of agreement between the number of coliforms detected in a water sample by the S-MPN, M-MPN, and MF techniques was a result of the selection for different coliform species by the various techniques. PMID:7013706
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources.
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli . PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources.
Pitkänen, Tarja; Paakkari, Piia; Miettinen, Ilkka T; Heinonen-Tanski, Helvi; Paulin, Lars; Hänninen, Marja-Liisa
2007-03-01
In this work alternative media for detection and enumeration of E. coli and coliform bacteria were compared to the reference method ISO 9308-1 (LTTC) using non-disinfected water samples with background flora. The alternative media included LES Endo agar medium (LES Endo), Colilert-18 with 51-well Quanti-tray (Colilert), Chromocult Coliform agar (CC), Harlequin E. coli/Coliform medium (HECM) and Chromogenic Escherichia coli/Coliform medium (CECM). A total of 110 samples of groundwater, bathing water and spiked water was used. Our results revealed that confirmation of coliform bacteria counts is necessary, not only on lactose-based LTTC and LES Endo media, but also on the chromogenic agar media tested, due to the growth of oxidase positive colonies. LTTC and CC media also allowed the growth of some morphologically typical coliform colonies containing gram-positive bacteria. The recovery of coliform bacteria was lower on LES Endo than on LTTC. In most cases Colilert, CC, HECM and CECM gave higher coliform counts than LTTC. The use of the LTTC medium led to higher E. coli counts than obtained with any of the alternative mediums. There are three explanations for this: (1) high sensitivity of LTTC, (2) false positives on LTTC or (3) false negatives especially with Colilert, but also with chromogenic agar media. Although LTTC was found to be a very sensitive medium, the high degree of background growth of non-disinfected waters disturbed substantially the use of it. In conclusion, our results suggest that Colilert, CC and CECM are potential alternative media for detection of coliform bacteria and E. coli from non-disinfected water.
Total Coliform Rule (TCR) Federal Register Notice
This document provides the FR notice to 40 CFR Parts 141 and 142 Drinking Water: National Primary Drinking Water Regulations; Total Coliforms (Including Fecal Coliforms and E. Coli); Final Rule (26 pp, 5 M).
Pathogen removal from domestic and swine wastewater by experimental constructed wetlands.
Giácoman-Vallejos, G; Ponce-Caballero, C; Champagne, P
2015-01-01
This study examined the performance of subsurface flow horizontal wetlands in total coliforms, faecal coliforms, enterococci and Salmonella removal from swine and domestic wastewaters. The effects of organic loading rate, contact time (CT) and the presence of aquatic macrophytes, Typha dominguensis and Typha latifolia, on treatment performance were evaluated. In general, chemical oxygen demand (COD) and total suspended solids (TSS) were reduced by 66 and 72% after 24 h and 75 and 84% after 48 h in domestic wastewaters, and 73 and 71% after 24 h and 72 and 78% after 48 h in swine wastewater. Total coliform and faecal coliform reductions of 70-83% and 65-78% were observed in the vegetated systems after 24 h of CT, while after 48 h, total coliform and faecal coliform reductions of 80-82% and 86-91% were noted.
Christensen, Sarah C. B.; Arvin, Erik; Nissen, Erling; Albrechtsen, Hans-Jørgen
2013-01-01
Individuals of the water louse, Asellus aquaticus, enter drinking water distribution systems in temperate parts of the world, where they establish breeding populations. We analysed populations of surface water A. aquaticus from two ponds for associated faecal indicator bacteria and assessed the risk of A. aquaticus transporting bacteria into distribution systems. Concentrations of up to two E. coli and five total coliforms·mL−1 were measured in the water and 200 E. coli and >240 total coliforms·mL−1 in the sediments of the investigated ponds. Concentrations of A. aquaticus associated bacteria never exceeded three E. coli and six total coliforms·A. aquaticus−1. During exposure to high concentrations of coliforms, concentrations reached 350 coliforms·A. aquaticus−1. A. aquaticus associated E. coli were only detected as long as E. coli were present in the water and sediment. The calculated probability of exceeding drinking water guideline values in non-disinfected systems by intrusion of A. aquaticus was low. Only in scenarios with narrow pipes and low flows, did total coliforms exceed guideline values, implying that the probability of detection by routine monitoring is also low. The study expands the knowledge base for evaluating incidents with presence of coliform indicators in drinking water by showing that intruding A. aquaticus were not important carriers of E. coli or other coliform bacteria even when emerging from faecally contaminated waters. PMID:23455399
Christensen, Sarah C B; Arvin, Erik; Nissen, Erling; Albrechtsen, Hans-Jørgen
2013-03-01
Individuals of the water louse, Asellus aquaticus, enter drinking water distribution systems in temperate parts of the world, where they establish breeding populations. We analysed populations of surface water A. aquaticus from two ponds for associated faecal indicator bacteria and assessed the risk of A. aquaticus transporting bacteria into distribution systems. Concentrations of up to two E. coli and five total coliforms·mL-1 were measured in the water and 200 E. coli and >240 total coliforms·mL-1 in the sediments of the investigated ponds. Concentrations of A. aquaticus associated bacteria never exceeded three E. coli and six total coliforms·A. aquaticus-1. During exposure to high concentrations of coliforms, concentrations reached 350 coliforms·A. aquaticus-1. A. aquaticus associated E. coli were only detected as long as E. coli were present in the water and sediment. The calculated probability of exceeding drinking water guideline values in non-disinfected systems by intrusion of A. aquaticus was low. Only in scenarios with narrow pipes and low flows, did total coliforms exceed guideline values, implying that the probability of detection by routine monitoring is also low. The study expands the knowledge base for evaluating incidents with presence of coliform indicators in drinking water by showing that intruding A. aquaticus were not important carriers of E. coli or other coliform bacteria even when emerging from faecally contaminated waters.
Identification of coliform genera recovered from water using different technologies.
Fricker, C R; Eldred, B J
2009-12-01
Methods for the detection of coliforms in water have changed significantly in recent years with procedures incorporating substrates for the detection of beta-d-galactosidase becoming more widely used. This study was undertaken to determine the range of coliform genera detected with methods that rely on lactose fermentation and compare them to those recovered using methods based upon beta-d-galactosidase. Coliform isolates were recovered from sewage-polluted water using m-endo, membrane lauryl sulfate broth, tergitol TTC agar, Colilert-18, ChromoCult and ColiScan for primary isolation. Organisms were grouped according to whether they had been isolated based upon lactose fermentation or beta-d-galactosidase production. A wide range of coliform genera were detected using both types of methods. There was considerable overlap between the two groups, and whilst differences were seen between the genera isolated with the two method types, no clear pattern emerged. Substantial numbers of 'new' coliforms (e.g. Raoutella spp.) were recovered using both types of methods. The results presented here confirm that both methods based on lactose fermentation or detection of beta-d-galactosidase activity recover a range of coliform organisms. Any suggestion that only methods which are based upon fermentation of lactose recover organisms of public health or regulatory significance cannot be substantiated. Furthermore, the higher recovery of coliform organisms from sewage-polluted water using methods utilizing beta-d-galactosidase-based methods does not appear to be because of the recovery of substantially more 'new' coliforms.
Niemi, R M; Heikkilä, M P; Lahti, K; Kalso, S; Niemelä, S I
2001-06-01
Enumeration of coliform bacteria and Escherichia coli is the most widely used method in the estimation of hygienic quality of drinking water. The yield of target bacteria and the species composition of different populations of coliform bacteria may depend on the method.Three methods were compared. Three membrane filtration methods were used for the enumeration of coliform bacteria in shallow well waters. The yield of confirmed coliform bacteria was highest on Differential Coliform agar, followed by LES Endo agar. Differential Coliform agar had the highest proportion of typical colonies, of which 74% were confirmed as belonging to the Enterobacteriaceae. Of the typical colonies on Lactose Tergitol 7 TTC agar, 75% were confirmed as Enterobacteriaceae, whereas 92% of typical colonies on LES Endo agar belonged to the Enterobacteriaceae. LES Endo agar yielded many Serratia strains, Lactose Tergitol 7 TTC agar yielded numerous strains of Rahnella aquatilis and Enterobacter, whereas Differential Coliform agar yielded the widest range of species. The yield of coliform bacteria varied between methods. Each method compared had a characteristic species distribution of target bacteria and a typical level of interference of non-target bacteria. Identification with routine physiological tests to distinct species was hampered by the slight differences between species. High yield and sufficient selectivity are difficult to achieve simultaneously, especially if the target group is diverse. The results showed that several aspects of method performance should be considered, and that the target group must be distinctly defined to enable method comparisons.
Maheux, Andrée F; Bouchard, Sébastien; Bérubé, Ève; Bergeron, Michel G
2017-06-01
The MI, Chromocult ® coliform, and Compass CC chromogenic culture-based methods used to assess water quality by the detection of Escherichia coli and total coliforms were compared in terms of their specificity and sensitivity, using 16S rRNA sequencing for colony identification. A sewage water sample was divided in 2-μL subsamples for testing by all three culture-based methods. All growing colonies were harvested and subjected to 16S rRNA sequencing. Test results showed that all E. coli colonies were correctly identified by all three methods, for a specificity and a sensitivity of 100%. However, for the total coliform detection, the MI agar, Chromocult ® coliform agar, and Compass CC agar were specific for only 69.2% (9/13), 47.2% (25/53), and 40.5% (17/42), whereas sensitive for 97.8% (45/46), 97.5% (39/40), and 85.7% (24/28), respectively. Thus, given the low level of specificity of these methods for the detection of total coliforms, confirming the identity of total coliform colonies could help to take public health decisions, in particular for cities connected to a public drinking water distribution system since the growth of few putative total coliform colonies on chromogenic agar is problematic and can lead to unnecessary and costly boiling notices from public health authorities.
Immunological Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins
1981-09-01
FA, Engert RF: Immunological interrelationships between cholera toxin and the heat -labile and hoat-stable enterotoxins of coliform bacteria. Infec...Immun 18:110, 1977 2. Klipstein FA, Engert RF: Immunological relationship of different preparations of coliform enterotoxins. Infec Immun 21:771, 1978...3. Klipstein FA, Engert RF: Reversal of jejunal water secretion by glucose in rats exposed to coliform enterotoxins. Gastroenteroloj y 75:255, 1978 4
Grabow, W O; Hilner, C A; Coubrough, P
1981-08-01
MacConkey agar, standard M-FC agar, M-FC agar without rosolic acid, M-FC agar with a resuscitation top layer, Teepol agar, and pads saturated with Teepol broth, were evaluated as growth media for membrane filtration counting of fecal coliform bacteria in water. In comparative tests on 312 samples of water from a wide variety of sources, including chlorinated effluents, M-FC agar without rosolic acid proved the medium of choice because it generally yielded the highest counts, was readily obtainable, easy to prepare and handle, and yielded clearly recognizable fecal coliform colonies. Identification of 1,139 fecal coliform isolates showed that fecal coliform tests cannot be used to enumerate Escherichia coli because the incidence of E. coli among fecal coliforms varied from an average of 51% for river water to 93% for an activated sludge effluent after chlorination. The incidence of Klebsiella pneumoniae among fecal coliforms varied from an average of 4% for the activated sludge effluent after chlorination to 32% for the river water. The advantages of a standard membrane filtration procedure for routine counting of fecal coliforms in water using M-FC agar without rosolic acid as growth medium, in the absence of preincubation or resuscitation steps, are outlined.
Escherichia coli and coliforms level of food utensils at food premises in Kuala Pilah, Malaysia
NASA Astrophysics Data System (ADS)
Saipullizan, Siti Nurul Ain; Mutalib, Sahilah Abd.; Sedek, Razalee
2018-04-01
The aim of this study was to evaluate the Escherichia coli and coliforms level of food utensils at sixty food premises in Kuala Pilah, Malaysia. The swab technique was used to investigate the presence of E. coli and coliforms on 180 of food utensils (chopping boards: 60, knives: 60 and dish plates: 60). The results indicated that 180 of food utensils were contaminated with E. coli and coliforms. More than 60% of the coliforms were exceeded the acceptable limit compared to E. coli on the food utensils. The one-way ANOVA analysis demonstrated that the presence of E. coli and coliforms differed significantly among the three types of food utensils (knives, chopping boards, and dish plates). In conclusion, this study revealed that there are hygiene issues exist in every food premises. The food utensils are safe to use during the food preparation if the presence of E. coli and coliforms are not exceed the acceptable limit. Thus, it is recommended that the food handlers in the food premises should improve effective cleaning and sanitizing of food utensils in their daily work.
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Background: Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Materials and Methods: Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Results: Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli. PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. Conclusion: The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources. PMID:29142893
Coliforms removal in full-scale activated sludge plants in India.
Kazmi, A A; Tyagi, V K; Trivedi, R C; Kumar, Arvind
2008-05-01
This paper investigates the removal of coliforms in full-scale activated sludge plants (ASP) operating in northern regions of India. Log2.2 and log2.4 removal were observed for total coliforms (TC) and fecal coliforms (FC), respectively. However, the effluent still contained a significant number of TC and FC which was greater than the permissible limit for unrestricted irrigation as prescribed by WHO. The observations also suggest that extended aeration (EA) process operating under high mixed liquor suspended solids (MLSS) and sludge retention time (SRT) is more efficient in the removal of coliforms. Further attempts have been made to establish the relationship between two key wastewater parameters, i.e. biochemical oxygen demand (BOD) and suspended solids (SS) with respect to fecal and TC. The relationships were observed to be linear with a good coefficient of correlation. The interrelationship of BOD and SS with coliforms manifest that improvement of the microbiological quality of wastewater could be linked with the removal of SS. Therefore, SS can serve as a regulatory tool in lieu of an explicit coliforms standard.
Revised Total Coliform Rule Assessments and Corrective Actions
EPA has developed the Revised Total Coliform Rule Assessment and Corrective Actions Guidance Manual for public water systems (e.g., owners and operators) to assist in complying with the requirements of the Revised Total Coliform Rule.
40 CFR 141.4 - Variances and exemptions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... coliform MCL of § 141.63(a) for systems that demonstrate to the State that the violation of the total coliform MCL is due to a persistent growth of total coliforms in the distribution system rather than fecal...
40 CFR 141.4 - Variances and exemptions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... coliform MCL of § 141.63(a) for systems that demonstrate to the State that the violation of the total coliform MCL is due to a persistent growth of total coliforms in the distribution system rather than fecal...
Högberg, A; Lindberg, JE; Wallgren, P
2001-01-01
The effect of surgery (insertion of an ileo-caecal cannula) and a subsequent parenteral treatment with oxytetracycline on the ileo-caecal and rectal coliform populations in 7 Swedish Yorkshire castrates were studied. Samples were collected during surgery as well as 3, 7, 14 and 20 days post surgery. The diversity of the enteric coliform flora was initially high both in the ileo-caecal ostium and in rectum. No alteration in the diversity of the enteric coliform flora was observed following surgery and treatment with oxytetracycline. As the insertion of ileo-caecal cannulas did not affect the intestinal coliform flora this study gives support to the use of this technique to mirror processes in the small intestine of pigs. Further, the diversity of the enteric coliform flora was unaffected by the parenteral treatment with oxytetracycline. PMID:11957371
Occurrence of fecal coliform bacteria in selected streams in Wyoming, 1990-99
Clark, Melanie L.; Norris, Jodi R.
2000-01-01
The U.S. Geological Survey (USGS), in cooperation with the Wyoming Department of Environmental Quality (WDEQ), is collecting water samples for analysis of fecal coliform bacteria at 18 stream sites as part of a statewide network. Contamination by bacteria of fecal origin in streams where contact recreation is a designated water use is a concern because of potential public-health risk from the presence of enteric pathogens. Fecal coliform concentrations are temporally and spatially variable in Wyoming streams-concentrations ranged from less than 1 to 45,000 colonies per 100 milliliters of water during 1990-99. Fecal coliform concentrations were less than the water-quality criterion of 400 colonies per 100 milliliters in 83 percent of the samples, indicating fecal coliform contamination is not a widespread problem in these Wyoming streams. However, 14 of the 18 monitoring sites had at least one sample in which the fecal coliform concentration exceeded 400 colonies per 100 milliliters at some time during the 10-year period. Fecal coliform concentrations generally are higher during April through September than during October through March. The higher concentrations coincide with the time period when the public-health risk is higher because summer months are when contact recreation use is more likely occurring. Fecal coliform concentrations were positively correlated with discharge and stream temperature and generally were negatively correlated with pH, specific conductance, and dissolved oxygen.
Cabral, João Paulo; Marques, Cristina
2006-07-01
Febros river water was sampled weekly, during 35 successive weeks, and analyzed for microbiological (total coliforms, faecal coliforms, faecal streptococci and enterococci) and chemical-physical (ammonia and temperature) parameters. All microbiological parameters were highly correlated with each other and with ammonia, suggesting that the simultaneous determination of all variables currently in use in the evaluation of the microbiological quality of waters is probably redundant, and could be simplified, and that ammonia should be tested as a sentinel parameter of the microbiological pollution load of Febros river. From the strains isolated from positive tubes of the faecal coliforms test (multiple tube fermentation technique) and retested in this assay, Escherichia coli, Klebsiella oxytoca and Klebsiella pneumoniae subsp. pneumoniae strains were positive, indicating that the faecal coliforms test is not totally specific for Escherichia coli, and can detect other bacteria. Considering that these Klebsiella spp. are not necessarily of faecal origin, it was concluded that the faecal coliforms test can overestimate true faecal pollution. From the strains isolated from positive tubes of the faecal coliforms procedure, only Escherichia coli strains were clearly positive in the beta-D-glucuronidase test. All other species were negative or very weakly positive, suggesting that the assay of the beta-D-glucuronidase activity is less prone to false positives than the faecal coliforms test in the quantification of Escherichia coli in environmental waters.
Akhter, Asma; Imran, Mohd; Akhter, Firoz
2014-01-01
The distribution of resistance to ampicillin, chloramphenicol, sulfonamides, tetracycline, and streptomycin among coliform in the Gomti river water samples was investigated. The coliform populations were isolated on Mac Conky and eosin methylene blue (EMB) agar plates supplemented with antibiotics. The incidence of resistance among the coliform population varied considerably in different drug and water sampling sites. Coliform bacteria showed lower drug resistant viable count in sampling site-III (receiving treated wastewater) as compared to more polluted site-I and site-II. Viable count of coliform population obtained on both medium was recorded higher against erythromycin from sampling site-III. Lower viable count of coliforms was recorded against tetracycline in site-II and III. Similar resistance pattern was obtained in the frequency of E. coli and Enterobacter species from all the three sampling sites. Percentage of antibiotic resistant E. coli was observed higher than Enterobacter spp among the total coliforms against all antibiotics tested without Erythromycin and penicillin in site-I and II respectively. Isolates of E. coli and Enterobacter spp. showed their tolerance level (MIC) in the range of 2-100 against the antibiotics tested. Maximum number of isolates of both genus exhibited their MICs at lower concentration range 2-5µg/ml against ciprofloxacin, tetracyclin and amoxycillin. EMB - Eosin methylene blue, IMViC tests - Indole, Methyl Red, Voges Proskauer and Citrate Utilization Tests, MIC - Minimum inhibitory concentration.
Akhter, Asma; Imran, Mohd; Akhter, Firoz
2014-01-01
The distribution of resistance to ampicillin, chloramphenicol, sulfonamides, tetracycline, and streptomycin among coliform in the Gomti river water samples was investigated. The coliform populations were isolated on Mac Conky and eosin methylene blue (EMB) agar plates supplemented with antibiotics. The incidence of resistance among the coliform population varied considerably in different drug and water sampling sites. Coliform bacteria showed lower drug resistant viable count in sampling site-III (receiving treated wastewater) as compared to more polluted site-I and site-II. Viable count of coliform population obtained on both medium was recorded higher against erythromycin from sampling site-III. Lower viable count of coliforms was recorded against tetracycline in site-II and III. Similar resistance pattern was obtained in the frequency of E. coli and Enterobacter species from all the three sampling sites. Percentage of antibiotic resistant E. coli was observed higher than Enterobacter spp among the total coliforms against all antibiotics tested without Erythromycin and penicillin in site-I and II respectively. Isolates of E. coli and Enterobacter spp. showed their tolerance level (MIC) in the range of 2-100 against the antibiotics tested. Maximum number of isolates of both genus exhibited their MICs at lower concentration range 2-5µg/ml against ciprofloxacin, tetracyclin and amoxycillin. Abbreviations EMB - Eosin methylene blue, IMViC tests - Indole, Methyl Red, Voges Proskauer and Citrate Utilization Tests, MIC - Minimum inhibitory concentration. PMID:24966515
Suzuki, Yoshihiro; Niina, Kouki; Matsuwaki, Tomonori; Nukazawa, Kei; Iguchi, Atsushi
2018-01-28
The aim of this study was to rapidly and effectively analyze coliforms, which are the most fundamental indicators of water quality for fecal pollution, using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Coliform bacteria were isolated from municipal sewage, river water, and groundwater. For each sample, 100 isolates were determined by MALDI-TOF MS. In addition, these same 100 isolates were also identified via 16S rRNA gene sequence analysis. Obtained MALDI-TOF MS data were compared with the 16S rRNA sequencing analysis, and the validity of MALDI-TOF MS for classification of coliform bacteria was examined. The concordance rate of bacterial identification for the 100 isolates obtained by MALDI-TOF MS analysis and 16S rRNA gene sequence analysis for sewage, river water, and ground water were 96%, 74%, and 62% at the genus level, respectively. Among the sewage, river water, and ground water samples, the coliform bacterial flora were distinct. The dominant genus of coliforms in sewage, river water, and groundwater were Klebsiella spp., Enterobacter spp., and Serratia spp., respectively. We determined that MALDI-TOF MS is a rapid and accurate tool that can be used to identify coliforms. Therefore, without using conventional 16S rRNA sequencing, it is possible to rapidly and effectively classify coliforms in water using MALDI-TOF MS.
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
Hong, Huachang; Qiu, Jianwen; Liang, Yan
2010-01-01
The Pearl River Delta (PRD) is one of the most developed and densely populated regions in China. Quantifying the amount of pathogens in the source of drinking water is important for improving water quality. We collected water samples from six major water storage reservoirs in the PRD region in both wet and dry seasons in 2006. Results showed that external environmental factors, such as precipitation, location, as well as the internal environmental factors, i.e., physicochemical properties of the water, were closely related with the distribution of coliforms. Seasonally, the coliform bacterial concentrations in wet season were one to two orders of magnitude greater than those in dry season. Spatially, coliform bacterial levels in reservoirs near urban and industrial areas were significantly higher (p < 0.05) than those in remote areas. Correlation analyses showed that the levels of coliforms had close relationships with pH, temperature, suspended solid, organic and inorganic nutrients in water. Principal components analysis further demonstrated that total coliforms in the reservoirs were closely related with water physicochemical properties, while fecal coliforms were more associated with external input brought in by seasonal runoff.
COMPOSITE SAMPLING FOR DETECTION OF COLIFORM BACTERIA IN WATER SUPPLY
Low densities of coliform bacteria introduced into distribution systems may survive in protected habitats. These organisms may interfere with and cause confusion in the use of the coliforms as indicators of sewage contamination of drinking water. Methods of increasing the probabi...
Pednekar, Abhishek M; Grant, Stanley B; Jeong, Youngsul; Poon, Ying; Oancea, Carmen
2005-12-01
Historical coliform measurements (n = 67,269; 32 years) in Newport Bay, a regionally important saltwater wetland and tidal embayment in southern California, have been compiled and analyzed. Coliform concentrations in Newport Bay decrease along an inland-to-ocean gradient, consistent with the hypothesis that this tidal embayment attenuates fecal pollution from inland sources. Nearly 70% of the variability in the coliform record can be attributed to seasonal and interannual variability in local rainfall, implying that stormwater runoff from the surrounding watershed is a primary source of coliform in Newport Bay. The storm loading rate of coliform from the San Diego Creek watershed--the largest watershed draining into Newport Bay--appears to be unaffected by the dramatic shift away from agricultural land-use that occurred in the watershed over the study period. Further, the peak loading of coliform during storms is larger than can be reasonably attributed to sources of human sewage, suggesting that nonhuman fecal pollution and/or bacterial regrowth contribute to the coliform load. Summer time measurements of coliform exhibit interannual trends, but these trends are site specific, apparently due to within-Bay variability in land-use, inputs of dry-weather runoff, and tidal mixing rates. Overall, these results suggest that efforts to improve water quality in Newport Bay will likely have greater efficacy during dry weather summer periods. Water quality during winter storms, on the other hand, appears to be dominated by factors outside of local management control; namely, virtually unlimited nonhuman sources of coliform in the watershed and global climate patterns, such as the El Nino Southern Oscillation, that modulate rainfall and stormwater runoff in southern California.
Reed, Brian C; Rasnake, Mark S
2016-03-01
Hikers and campers are exposed to risks while in the wilderness. One of these risks is the possibility of contracting an illness, including infectious diarrhea. This project tested for coliform bacteria in water samples taken near popular Appalachian Trail shelters. Water was collected from access points within the Great Smoky Mountains National Park. Samples were collected in sterile bottles and inoculated on a commercially available coliform detection kit for quantitative determination of total coliform and Escherichia coli counts. Water samples were taken during summer and fall seasons. During summer, 7 of 10 samples were positive for coliform bacteria and 6 of those 7 for E coli. The most probable number (MPN) of colony-forming units (CFU) for coliform bacteria ranged from 0 to 489 CFU/100 mL, with the MPN for E coli varying from 0 to 123 CFU/100 mL. These data differed from the fall collection, revealing 3 of 7 samples positive for coliform bacteria and 1 of those 3 for E coli. The MPN of CFU for coliform bacteria in fall samples varied from 0 to 119 CFU/100 mL and 0 to 5 to CFU/100 mL for E coli. Environmental Protection Agency drinking water standards set the standard of 0 CFU/100 mL to be considered safe. This analysis of water samples along the Appalachian Trail emphasizes that the majority of water access points require treatment during the summer season. Coliform burden was not as high through the fall months. These data suggest one infectious disease risk for wilderness travelers. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Coliform sampling. 141.803 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.803 Coliform sampling. (a) Analytical methodology. Air carriers must follow the sampling and analysis requirements under this section...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling. 141.803 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.803 Coliform sampling. (a) Analytical methodology. Air carriers must follow the sampling and analysis requirements under this section...
Gondal, Mohammed A; Khalil, Amjad
2008-04-01
Laser-induced photo-catalysis process using WO(3) semiconductor catalyst was applied for the study of disinfection effectiveness of E-coliform-contaminated water. For this purpose, wastewater polluted with E-coliform bacteria was exposed to 355 nm UV radiations generated by third harmonic of Nd: YAG laser in special glass cell with and without WO(3) catalyst. E-Coliform quantification was performed by direct plating method to obtain the efficiency of each disinfection treatment. The dependence of disinfection process on laser irradiation energy, amount of catalyst and duration of laser irradiation was also investigated. The disinfection with WO(3) was quite efficient inactivating E-coliforms. For inactivation of E-coliforms, less than 8 minutes' laser irradiation was required, so that, the treated water complies with the microbial standards for drinking water. This study opens the possibility of application of this simple method in rural areas of developing countries using solar radiation.
Effect of turbidity on chlorination efficiency and bacterial persistence in drinking water.
LeChevallier, M W; Evans, T M; Seidler, R J
1981-01-01
To define interrelationships between elevated turbidities and the efficiency of chlorination in drinking water, experiments were performed to measure bacterial survival, chlorine demand, and interference with microbiological determinations. Experiments were conducted on the surface water supplies for communities which practice chlorination as the only treatment. Therefore, the conclusions of this study apply only to such systems. Results indicated that disinfection efficiency (log10 of the decrease in coliform numbers) was negatively correlated with turbidity and was influenced by season, chlorine demand of the samples, and the initial coliform level. Total organic carbon was found to be associated with turbidity and was shown to interfere with maintenance of a free chlorine residual by creating a chlorine demand. Interference with coliform detection in turbid waters could be demonstrated by the recovery of typical coliforms from apparently negative filters. The incidence of coliform masking in the membrane filter technique was found to increase as the turbidity of the chlorinated samples increased. the magnitude of coliform masking in the membrane filter technique increased from less than 1 coliform per 100 ml in water samples of less than 5 nephelometric turbidity units to greater than 1 coliform per 100 ml in water samples of greater than 5 nephelometric turbidity units. Statistical models were developed to predict the impact of turbidity on drinking water quality. The results justify maximum contaminant levels for turbidity in water entering a distribution system as stated in the National Primary Drinking Water Regulations of the Safe Drinking Water Act. Images PMID:7259162
Microbiological contamination in water filtration plants in Islamabad.
Hisam, Aliya; Ur Rahman, Mahmood; Kadir, Ehsan; Tariq, Naseer Alam; Masood, Sumaira
2014-05-01
To determine the frequency of microbiological contamination of water in different water filtration plants in Islamabad. Descriptive cross-sectional study. Water Filtration Plants (WFP) in different sectors of Islamabad, from April to September 2012. Water samples were collected in sterilized bottles according to the standard water sampling protocol from site and transported to Pakistan Council for Research in Water Resources (PCRWR) for analysis. Microbiological quality of water was determined in terms of total coliforms (< 2.0 MPN/100 ml) and Escherichia coli (< 2.0 MPN/100 ml). Microbiological contaminated water was defined the sample which had more than 2.0 MPN per 100 ml of either total coliforms or Escherichia (E.) coli. Thirty two WFP were analyzed for microbiological contamination. E. coli was present in 8 (25.0%) water samples, while 24 (75.0%) water samples were free from it. Total coliforms were present in 13 (40.6%) of the samples of WFP, while 19 (59.3%) samples were free from total coliform. Faecal coliforms were present in 8 (25.0%) and absent in 24 (75.0%) samples. Both E. coli and total coliform were present in 8 (25.0%) samples. Nine (59.3) WFP were free from E. coli, total coliform and faecal coliform. Statistically, no significant association was found (p > 0.05) between microbiological contamination and the sectors. Less than half of the water samples of the WFP were contaminated while certain sectors showed more frequent contamination than others.
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Coliform sampling plan. 141.802... sampling plan. (a) Each air carrier under this subpart must develop a coliform sampling plan covering each... required actions, including repeat and follow-up sampling, corrective action, and notification of...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling plan. 141.802... sampling plan. (a) Each air carrier under this subpart must develop a coliform sampling plan covering each... required actions, including repeat and follow-up sampling, corrective action, and notification of...
CORRELATION OF COLIFORM GROWTH RESPONSE WITH OTHER WATER QUALITY PARAMETERS
A variety of water types collected from different geographical areas at different stages of water treatment were anlayzed for their ability to support the growth of coliform bacteria. Based on this coliform bioassay, the nutrient status of the water did not correlate with any of...
40 CFR 142.63 - Variances and exemptions from the maximum contaminant level for total coliforms.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) EPA has stayed the effective date of this section relating to the total coliform MCL of § 141.63(a) of this chapter for systems that demonstrate to the State that the violation of the total coliform MCL is...
Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then...
Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-16
... Currently Approved Total Coliform Analytical Methods AGENCY: Environmental Protection Agency (EPA). ACTION... of currently approved Total Coliform Rule (TCR) analytical methods. At these meetings, stakeholders will be given an opportunity to discuss potential elements of a method re-evaluation study, such as...
75 FR 42440 - Total Coliform Rule Revisions-Notice of Public Information Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-21
... will be discussed include the cost and benefit information of the proposed rule and the planned... ENVIRONMENTAL PROTECTION AGENCY [FRL-9177-6] Total Coliform Rule Revisions--Notice of Public... Protection Agency (EPA) is hosting public information meetings on the proposed Revised Total Coliform Rule...
33 CFR 159.123 - Coliform test: Type I devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coliform test: Type I devices. 159.123 Section 159.123 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.123 Coliform test...
33 CFR 159.126 - Coliform test: Type II devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coliform test: Type II devices. 159.126 Section 159.126 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.126 Coliform test...
Test/QA Plan for Verification of Coliform Detection Technologies for Drinking Water
The coliform detection technologies to be tested use chromatogenic and fluorogenic growth media to detect coliforms and E. coli based on the enzymatic activity of these organisms. The systems consist of single-use sample containers that contain pre-measured reagents and can be u...
ESCHERICHIA COLI AND TOTAL COLIFORMS IN WATER AND SEDIMENTS AT LAKE MARINAS
Escherichia coli, a fecal coliform, and total coliforms were monitored between September 1999 to October 2001 in five marinas on Lake Texoma, located on the Oklahoma and Texas border. General trend was that densities of E. coli were lower in the summer season due to the lower ...
1989-09-01
granitics is indicated by the Tungsten Peak Mine, which produced 180 acre-feetof waterper year when in operation. Besides evaporation from China Lake Playa ... coliform colonies /100 mL Fecal coliform colonies /100 mL Fecal streptococci colonies /100 mL Alkalinity: Carbonate mg/L Bicarbonate mg/L 3 Observations and...type and No. mg/L Sarometric pressure mm/Hg Calibration value mg/L Total coliform _ _ colonies /100 mL Fecal coliform colonies 1100 mLFwwl strelptocc
Rosas, I; Báez, A; Coutiño, M
1984-01-01
Xochimilco county plots (Mexico City), one of the most fertile agricultural areas in the Valley of Mexico, produce a large portion of the fresh vegetables consumed in the city. These plots are generally irrigated with domestic wastewater, and for this reason, it was deemed important to examine and evaluate the bacteriological quality of the water, soil, and vegetables from these plots that are harvested and marketed. The soils were also examined for the classical parameters such as nitrates, ammonia, etc., and organic matter and texture. The crops selected for this study were radishes, spinach, lettuce, parsley, and celery because they are usually consumed raw. The highest bacterial counts were encountered in leafy vegetables, i.e., spinach (8,700 for total coliform and 2,400 for fecal coliform) and lettuce (37,000 for total coliform and 3,600 for fecal coliform). Statistically significant differences in bacterial counts between rinsed and unrinsed edible portions of the crops were observed even in rinsed vegetables, and high densities of fecal coliform were detected, indicating that their consumption represents a potential health hazard. The total coliform values found in irrigation water ranged from 4 X 10(4) to 29 X 10(4), and for fecal coliform the values ranged from 5 X 10(2) to 30 X 10(2). PMID:6742825
Mavangira, Vengai; Gandy, Jeffery C; Zhang, Chen; Ryman, Valerie E; Daniel Jones, A; Sordillo, Lorraine M
2015-09-01
Coliform mastitis is a severe and sometimes fatal disease characterized by an unregulated inflammatory response. The initiation, progression, and resolution of inflammatory responses are regulated, in part, by potent oxylipid metabolites derived from polyunsaturated fatty acids. The purpose of this study was to characterize the biosynthesis and diversity of oxylipid metabolites during acute bovine coliform mastitis. Eleven cows diagnosed with naturally occurring acute systemic coliform mastitis and 13 healthy control cows, matched for lactation number and days in milk, were selected for comparison of oxylipid and free fatty acid concentrations in both milk and plasma. Oxylipids and free fatty acids were quantified using liquid chromatography-tandem mass spectrometry. All polyunsaturated fatty acids quantified in milk were elevated during coliform mastitis with linoleic acid being the most abundant. Oxylipids synthesized through the lipoxygenase and cytochrome P450 pathways accounted for the majority of the oxylipid biosynthesis. This study demonstrated a complex and diverse oxylipid network, most pronounced at the level of the mammary gland. Substrate availability, biosynthetic pathways, and degree of metabolism influence the biosynthesis of oxylipids during bovine coliform mastitis. Further studies are required to identify targets for novel interventions that modulate oxylipid biosynthesis during coliform mastitis to optimize inflammation. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Bacteriological and Physical Quality of Locally Packaged Drinking Water in Kampala, Uganda
Halage, Abdullah Ali; Ssemugabo, Charles; Ssemwanga, David K.; Musoke, David; Mugambe, Richard K.; Guwatudde, David; Ssempebwa, John C.
2015-01-01
Objective. To assess the bacteriological and physical quality of locally packaged drinking water sold for public consumption. Methods. This was cross-sectional study where a total of 60 samples of bottled water from 10 brands and 30 samples of sachet water from 15 brands purchased randomly were analyzed for bacteriological contamination (total coliform and faecal coliform per 100 mL) using membrane filtrate method and reported in terms of cfu/100 mL. Results. Both bottled water and sachet water were not contaminated with faecal coliform. Majority (70%, 21/30) of the sachet water analyzed exceeded acceptable limits of 0 total coliforms per 100 mL set by WHO and the national drinking water standards. The physical quality (turbidity and pH) of all the packaged water brands analyzed was within the acceptable limits. There was statistically significant difference between the median count of total coliform in both sachet water and bottled water brands (U(24) = 37.0, p = 0.027). Conclusion. Both bottled water and sachet water were not contaminated with faecal coliforms; majority of sachet water was contaminated with total coliform above acceptable limits. Government and other stakeholders should consider intensifying surveillance activities and enforcing strict hygienic measures in this rapidly expanding industry to improve packaged water quality. PMID:26508915
Bacteriological and physical quality of locally packaged drinking water in Kampala, Uganda.
Halage, Abdullah Ali; Ssemugabo, Charles; Ssemwanga, David K; Musoke, David; Mugambe, Richard K; Guwatudde, David; Ssempebwa, John C
2015-01-01
To assess the bacteriological and physical quality of locally packaged drinking water sold for public consumption. This was cross-sectional study where a total of 60 samples of bottled water from 10 brands and 30 samples of sachet water from 15 brands purchased randomly were analyzed for bacteriological contamination (total coliform and faecal coliform per 100 mL) using membrane filtrate method and reported in terms of cfu/100 mL. Both bottled water and sachet water were not contaminated with faecal coliform. Majority (70%, 21/30) of the sachet water analyzed exceeded acceptable limits of 0 total coliforms per 100 mL set by WHO and the national drinking water standards. The physical quality (turbidity and pH) of all the packaged water brands analyzed was within the acceptable limits. There was statistically significant difference between the median count of total coliform in both sachet water and bottled water brands (U(24) = 37.0, p = 0.027). Both bottled water and sachet water were not contaminated with faecal coliforms; majority of sachet water was contaminated with total coliform above acceptable limits. Government and other stakeholders should consider intensifying surveillance activities and enforcing strict hygienic measures in this rapidly expanding industry to improve packaged water quality.
Rosas, I; Báez, A; Coutiño, M
1984-05-01
Xochimilco county plots (Mexico City), one of the most fertile agricultural areas in the Valley of Mexico, produce a large portion of the fresh vegetables consumed in the city. These plots are generally irrigated with domestic wastewater, and for this reason, it was deemed important to examine and evaluate the bacteriological quality of the water, soil, and vegetables from these plots that are harvested and marketed. The soils were also examined for the classical parameters such as nitrates, ammonia, etc., and organic matter and texture. The crops selected for this study were radishes, spinach, lettuce, parsley, and celery because they are usually consumed raw. The highest bacterial counts were encountered in leafy vegetables, i.e., spinach (8,700 for total coliform and 2,400 for fecal coliform) and lettuce (37,000 for total coliform and 3,600 for fecal coliform). Statistically significant differences in bacterial counts between rinsed and unrinsed edible portions of the crops were observed even in rinsed vegetables, and high densities of fecal coliform were detected, indicating that their consumption represents a potential health hazard. The total coliform values found in irrigation water ranged from 4 X 10(4) to 29 X 10(4), and for fecal coliform the values ranged from 5 X 10(2) to 30 X 10(2).
Fecal coliform accumulation within a river subject to seasonally-disinfected wastewater discharges.
Mitch, Azalea A; Gasner, Katherine C; Mitch, William A
2010-09-01
As pathogen contamination is a leading cause of surface water impairment, there has been increasing interest in the implications of seasonal disinfection practices of wastewater effluents for meeting water quality goals. For receiving waters designated for recreational use, disinfection during the winter months is often considered unnecessary due to reduced recreational usage, and assumptions that lower temperatures may reduce pathogen accumulation. For a river subject to seasonal disinfection, we sought to evaluate whether fecal coliforms accumulate during the winter to concentrations that would impair river water quality. Samples were collected from municipal wastewater outfalls along the river, as well as upstream and downstream of each outfall during the winter, when disinfection is not practiced, and during the summer, when disinfection is practiced. During both seasons, fecal coliform concentrations reached 2000-5000 CFU/100 mL, nearly an order of magnitude higher than levels targeted for the river to achieve primary contact recreational uses. During the summer, wastewater effluents were not significant contributors to fecal coliform loadings to the river. During the winter, fecal coliform accumulated along the river predominantly due to loadings from successive wastewater outfalls. In addition to the exceedance of fecal coliform criteria within the river, the accumulation of wastewater-derived fecal coliform along the river during the winter season suggests that wastewater outfalls may contribute elevated loads of pathogens to the commercial shellfish operations occurring at the mouth of the river. Reductions in fecal coliform concentrations between wastewater outfalls were attributed to dilution or overall removal. Combining discharge measurements from gauging stations, tributaries and wastewater outfalls to estimate seepage, dilution between wastewater outfalls was estimated, along with the percentage of the river deriving from wastewater outfalls. After accounting for dilution, the residual reductions in fecal coliform concentrations observed between outfalls were attributed to actual fecal coliform removal. The estimated rate of removal of 1.52 d(-1) was significantly higher than die-off rates determined by previous researchers at similarly low temperatures in laboratory batch experiments, indicating the potential importance of other removal mechanisms, such as predation or sedimentation. Copyright © 2010 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-08
... Identification of Coliform Bacteria and Escherichia coli in Finished Waters, January 2007, Version 1.1... Membrane Filter Test Method for Detection and Identification of Coliform Bacteria and Escherichia coli in... Detection and Identification of Coliform Bacteria and Escherichia coli in Finished Waters. November, 2000...
Code of Federal Regulations, 2013 CFR
2013-07-01
... REGULATIONS Revised Total Coliform Rule § 141.857 Routine monitoring requirements for public water systems... systems serving more than 1,000 persons. (2) Following any total coliform-positive sample taken under the... calendar month has been completed, systems must determine whether any coliform treatment technique triggers...
40 CFR 141.853 - General monitoring requirements for all public water systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Coliform Rule § 141.853 General monitoring requirements for all public water systems. (a) Sample siting... 31, 2016. These plans are subject to State review and revision. Systems must collect total coliform... MCL violation or has exceeded the coliform treatment technique triggers in § 141.859(a). (4) A system...
Wastewater disinfection alternatives: chlorine, ozone, peracetic acid, and UV light.
Mezzanotte, V; Antonelli, M; Citterio, S; Nurizzo, C
2007-11-01
Disinfection tests were carried out at pilot scale to compare the disinfection efficiency of ozone, sodium hypochlorite (NaOCl), peracetic acid (PAA), and UV irradiation. Total coliforms, fecal coliforms, and Escherichia coli were monitored as reference microorganisms. Total heterotrophic bacteria (THB) were also enumerated by cytometry. At similar doses, NaOCl was more effective than PAA, and its action was less affected by contact time. The results obtained by ozonation were comparable for total coliforms, fecal coliforms, and E. coli. On the contrary, some differences among the three indicators were observed for NaOCl, PAA, and UV. Differences increased with increasing values of the disinfectant concentration times contact time (C x t) and were probably the result of different initial counts, as total coliforms include fecal coliforms, which include E. coli. The UV irradiation lead to complete E. coli removals, even at low doses (10 to 20 mJ/cm2). Total heterotrophic bacteria appeared to be too wide a group to be a good disinfection indicator; no correlation was found among THB inactivation, dose, and contact time.
Rasmussen, Patrick P.; Ziegler, Andrew C.
2003-01-01
The sanitary quality of water and its use as a public-water supply and for recreational activities, such as swimming, wading, boating, and fishing, can be evaluated on the basis of fecal coliform and Escherichia coli (E. coli) bacteria densities. This report describes the overall sanitary quality of surface water in selected Kansas streams, the relation between fecal coliform and E. coli, the relation between turbidity and bacteria densities, and how continuous bacteria estimates can be used to evaluate the water-quality conditions in selected Kansas streams. Samples for fecal coliform and E. coli were collected at 28 surface-water sites in Kansas. Of the 318 samples collected, 18 percent exceeded the current Kansas Department of Health and Environment (KDHE) secondary contact recreational, single-sample criterion for fecal coliform (2,000 colonies per 100 milliliters of water). Of the 219 samples collected during the recreation months (April 1 through October 31), 21 percent exceeded the current (2003) KDHE single-sample fecal coliform criterion for secondary contact rec-reation (2,000 colonies per 100 milliliters of water) and 36 percent exceeded the U.S. Environmental Protection Agency (USEPA) recommended single-sample primary contact recreational criterion for E. coli (576 colonies per 100 milliliters of water). Comparisons of fecal coliform and E. coli criteria indicated that more than one-half of the streams sampled could exceed USEPA recommended E. coli criteria more frequently than the current KDHE fecal coliform criteria. In addition, the ratios of E. coli to fecal coliform (EC/FC) were smallest for sites with slightly saline water (specific conductance greater than 1,000 microsiemens per centimeter at 25 degrees Celsius), indicating that E. coli may not be a good indicator of sanitary quality for those streams. Enterococci bacteria may provide a more accurate assessment of the potential for swimming-related illnesses in these streams. Ratios of EC/FC and linear regression models were developed for estimating E. coli densities on the basis of measured fecal coliform densities for six individual and six groups of surface-water sites. Regression models developed for the six individual surface-water sites and six groups of sites explain at least 89 percent of the variability in E. coli densities. The EC/FC ratios and regression models are site specific and make it possible to convert historic fecal coliform bacteria data to estimated E. coli densities for the selected sites. The EC/FC ratios can be used to estimate E. coli for any range of historical fecal coliform densities, and in some cases with less error than the regression models. The basin- and statewide regression models explained at least 93 percent of the variance and best represent the sites where a majority of the data used to develop the models were collected (Kansas and Little Arkansas Basins). Comparison of the current (2003) KDHE geometric-mean primary contact criterion for fecal coliform bacteria of 200 col/100 mL to the 2002 USEPA recommended geometric-mean criterion of 126 col/100 mL for E. coli results in an EC/FC ratio of 0.63. The geometric-mean EC/FC ratio for all sites except Rattlesnake Creek (site 21) is 0.77, indicating that considerably more than 63 percent of the fecal coliform is E. coli. This potentially could lead to more exceedances of the recommended E. coli criterion, where the water now meets the current (2003) 200-col/100 mL fecal coliform criterion. In this report, turbidity was found to be a reliable estimator of bacteria densities. Regression models are provided for estimating fecal coliform and E. coli bacteria densities using continuous turbidity measurements. Prediction intervals also are provided to show the uncertainty associated with using the regression models. Eighty percent of all measured sample densities and individual turbidity-based estimates from the regression models were in agreement as exceedi
2011-01-01
Background Infantile colic is a common disturb within the first 3 months of life, nevertheless the pathogenesis is incompletely understood and treatment remains an open issue. Intestinal gas production is thought to be one of the causes of abdominal discomfort in infants suffering from colic. However, data about the role of the amount of gas produced by infants' colonic microbiota and the correlation with the onset of colic symptoms are scanty. The benefit of supplementation with lactobacilli been recently reported but the mechanisms by which they exert their effects have not yet been fully defined. This study was performed to evaluate the interaction between Lactobacillus spp. strains and gas-forming coliforms isolated from stools of colicky infants. Results Strains of coliforms were isolated from stools of 45 colicky and 42 control breastfed infants in McConkey Agar and identified using PCR with species-specific primers, and the BBL™ Enterotube™ II system for Enterobacteriaceae. Gas-forming capability of coliforms was assessed in liquid cultures containing lactose as sole carbon source. The average count of total coliforms in colicky infants was significantly higher than controls: 5.98 (2.00-8.76) log10 vs 3.90 (2.50-7.10) CFU/g of faeces (p = 0.015). The following strains were identified: Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter aerogenes, Enterobacter cloacae and Enterococcus faecalis. Then, 27 Lactobacillus strains were tested for their antagonistic effect against coliforms both by halo-forming method and in liquid co-cultures. Lactobacillus delbrueckii subsp.delbrueckii DSM 20074 and L. plantarum MB 456 were able to inhibit all coliforms strains (halo-forming method), also in liquid co-cultures, thus demonstrating an antagonistic activity. Conclusions This study shows that two out of 27 strains of Lactobacillus examined possess an antimicrobial effect against six species of gas-forming coliforms isolated from colicky infants. Our findings may stimulate new researches to identify which Lactobacillus strains can improve colicky symptoms by acting on coliforms gut colonization. PMID:21718486
Savino, Francesco; Cordisco, Lisa; Tarasco, Valentina; Locatelli, Emanuela; Di Gioia, Diana; Oggero, Roberto; Matteuzzi, Diego
2011-06-30
Infantile colic is a common disturb within the first 3 months of life, nevertheless the pathogenesis is incompletely understood and treatment remains an open issue. Intestinal gas production is thought to be one of the causes of abdominal discomfort in infants suffering from colic. However, data about the role of the amount of gas produced by infants' colonic microbiota and the correlation with the onset of colic symptoms are scanty. The benefit of supplementation with lactobacilli been recently reported but the mechanisms by which they exert their effects have not yet been fully defined. This study was performed to evaluate the interaction between Lactobacillus spp. strains and gas-forming coliforms isolated from stools of colicky infants. Strains of coliforms were isolated from stools of 45 colicky and 42 control breastfed infants in McConkey Agar and identified using PCR with species-specific primers, and the BBL™ Enterotube™ II system for Enterobacteriaceae. Gas-forming capability of coliforms was assessed in liquid cultures containing lactose as sole carbon source. The average count of total coliforms in colicky infants was significantly higher than controls: 5.98 (2.00-8.76) log10 vs 3.90 (2.50-7.10) CFU/g of faeces (p = 0.015). The following strains were identified: Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter aerogenes, Enterobacter cloacae and Enterococcus faecalis. Then, 27 Lactobacillus strains were tested for their antagonistic effect against coliforms both by halo-forming method and in liquid co-cultures. Lactobacillus delbrueckii subsp. delbrueckii DSM 20074 and L. plantarum MB 456 were able to inhibit all coliforms strains (halo-forming method), also in liquid co-cultures, thus demonstrating an antagonistic activity. This study shows that two out of 27 strains of Lactobacillus examined possess an antimicrobial effect against six species of gas-forming coliforms isolated from colicky infants. Our findings may stimulate new researches to identify which Lactobacillus strains can improve colicky symptoms by acting on coliforms gut colonization.
Yeung-Cheung, Anna K; Melendez, Nadilynn J
2007-02-01
Harbor Island Park of Mamaroneck Harbor is one of the beaches that has been frequently closed to the public due to unsanitary swimming conditions. In 2002, a Gunderboom BPS (Beach Protection System) was reinstalled in Harbor Island Park to lower bacterial levels in swimming areas. The first Gunderboom had been destroyed by an oil spill several years before. The current Gunderboom is an 800 foot curtain made of a treated polypropylene/polyester fabric and the company claims a 99.1% coliform reduction with its use. In this study, water inside and outside the Gunderboom was tested weekly from June to August 2005, and bi-weekly from September to December 2005. Coliscan Membrane Filtration plates were used to recover the relative amounts of Escherichia coli and coliform bacteria from the water. Soft-shelled clams (Mya arenaria) living in both these areas were also tested for their E. coli and coliform bacteria level using 3M Petrifilm plates. Water was also tested from Hudson Park in New Rochelle, a frequently closed beach due to high levels of coliform bacteria, as well as from Read Sanctuary in Rye, a "pristine" beach. Our results showed the amount of E. coli and coliform bacteria recovered from the water inside the Gunderboom were significantly lower (P < 0.05) compared to outside the Gunderboom and Hudson Park. There was 81.9% reduction in E. coli and 51.6% reduction in coliform bacteria inside the Gunderboom as compared to the outside. In addition, significant differences (P < 0.05) were found with lower numbers of E. coli and coliform bacteria recovered from the clams inside the Gunderboom compared to outside the Gunderboom. In conclusion, the Gunderboom system installed in Mamaroneck Harbor resulted in a significant reduction of E. coli and coliform bacteria in the water and clam samples, thus proving its efficiency as a water filter.
Factors Associated with the Presence of Coliforms in the Feed and Water of Feedlot Cattle
Sanderson, Michael W.; Sargeant, Jan M.; Renter, David G.; Griffin, D. Dee; Smith, Robert A.
2005-01-01
The objective of this study was to investigate coliform counts in feedlot cattle water and feed rations and their associations with management, climate, fecal material, and water Escherichia coli O157 using a cross-sectional study design. Coliform counts were performed on feed samples from 671 pens on 70 feedlots and on water samples from 702 pens on 72 feedlots in four U.S. states collected between May and August 2001. Management and climate factors were obtained by survey and observation. Month of sampling (higher in May and June), presence of corn silage in the ration (negative association), temperature of the feed 1 in. (ca. 2.5 cm) below the surface at the time of sampling (negative association), and wind velocity at the time of sampling (positive association) were significantly associated with log10 coliform levels in feed. Month of sampling (lower in May versus June July and August), water pH (negative association), and water total solids (positive association) were significantly associated with log10 water coliform levels. Coliform counts in feed and water were not associated with prevalence of E. coli O157 in cattle feces or water. Management risk factors must be interpreted with caution but the results reported here do not support the use of coliform counts as a marker for E. coli O157 contamination of feed or water. PMID:16204517
USDA-ARS?s Scientific Manuscript database
The fecal coliform, Escherichia coli, is a historical organism for the detection of fecal pollution in water supplies. The presence of E. coli indicates a potential contamination of the water supply by other more hazardous human pathogens. In order to accurately determine the presence and degree o...
Code of Federal Regulations, 2013 CFR
2013-07-01
... WATER REGULATIONS Revised Total Coliform Rule § 141.856 Routine monitoring requirements for subpart H... coliform-positive sample taken under the provisions of this section, systems must comply with the repeat... coliform treatment technique triggers specified in § 141.859 have been exceeded. If any trigger has been...
Patterns and sources of fecal coliform bacteria in three streams in Virginia, 1999-2000
Hyer, Kenneth; Moyer, Douglas
2003-01-01
Surface-water impairment by fecal coliform bacteria is a water-quality issue of national scope and importance. In Virginia, more than 175 stream segments are on the Commonwealth's 1998 303(d) list of impaired waters because of elevated concentrations of fecal coliform bacteria. These fecal coliform-impaired stream segments require the development of total maximum daily load (TMDL) and associated implementation plans, but accurate information on the sources contributing these bacteria usually is lacking. The development of defendable fecal coliform TMDLs and management plans can benefit from reliable information on the bacteria sources that are responsible for the impairment. Bacterial source tracking (BST) recently has emerged as a powerful tool for identifying the sources of fecal coliform bacteria that impair surface waters. In a demonstration of BST technology, three watersheds on Virginia's 1998 303(d) list with diverse land-use practices (and potentially diverse bacteria sources) were studied. Accotink Creek is dominated by urban land uses, Christians Creek by agricultural land uses, and Blacks Run is affected by both urban and agricultural land uses. During the 20-month field study (March 1999?October 2000), water samples were collected from each stream during a range of flow conditions and seasons. For each sample, specific conductance, dissolved oxygen concentration, pH, turbidity, flow, and water temperature were measured. Fecal coliform concentrations of each water sample were determined using the membrane filtration technique. Next, Escherichia coli (E. coli) were isolated from the fecal coliform bacteria and their sources were identified using ribotyping (a method of 'genetic fingerprinting'). Study results provide enhanced understanding of the concentrations and sources of fecal coliform bacteria in these three watersheds. Continuum sampling (sampling along the length of the streams) indicated that elevated concentrations of fecal coliform bacteria (maximum observed concentration of 290,000 colonies/100 milliliters (col/100mL) could occur along the entire length of each stream, and that the samples collected at the downstream monitoring station of each stream were generally representative of the entire upstream reach. Seasonal patterns were observed in the base-flow fecal coliform concentrations of all streams; concentrations were typically highest in the summer and lowest in the winter. Fecal coliform concentrations were lowest during periods of base flow (typically 200?2,000 col/100mL) and increased by 3?4 orders of magnitude during storm events (as high as 700,000 col/100mL). Multiple linear regression models were developed to predict fecal coliform concentrations as a function of streamflow and other water-quality parameters. The source tracking technique provided identification of bacteria contributions from diverse sources that included (but were not limited to) humans, cattle, poultry, horses, dogs, cats, geese, ducks, raccoons, and deer. Seasonal patterns were observed in the contributions of cattle and poultry sources. There were relations between the identified sources of fecal coliform bacteria and the land-use practices within each watershed. There were only minor differences in the distribution of bacteria sources between low-flow periods and high-flow periods. A coupled approach that utilized both a large available source library and a smaller, location-specific source library provided the most success in identifying the unknown E. coli isolates. BST data should provide valuable support and guidance for producing more defendable and scientifically rigorous watershed models. Incorporation of these bacteria-source data into watershed management strategies also should result in the selection of more efficient source-reduction scenarios for improving water quality.
Abass, Kabila; Ganle, John Kuumuori; Adaborna, Eric
2016-04-01
Peri-urban vegetable farming in Ghana is an important livelihood activity for an increasing number of people. However, increasing quality and public health concerns have been raised, partly because freshwater availability for irrigation purposes is a major constraint. This paper investigated on-farm vegetable contamination and potential health risks using samples of lettuce, spring onions and cabbage randomly selected from 18 vegetable farms in peri-urban Kumasi, Ghana. Vegetable samples were tested for total coliform, fecal coliform, Escherichia coli and Salmonella spp. bacteria contamination using the Most Probable Number method. Results show high contamination levels of total and fecal coliforms, and Escherichia coli bacteria in all 18 vegetable samples. The mean total coliform/100 ml concentration for spring onions, lettuce and cabbage were 9.15 × 10(9), 4.7 × 10(7) and 8.3 × 10(7) respectively. The mean fecal coliform concentration for spring onions, lettuce and cabbage were also 1.5 × 10(8), 4.15 × 10(7) and 2.15 × 10(7) respectively, while the mean Escherichia coli bacteria contamination for spring onions, lettuce and cabbage were 1.4 × 10(8), 2.2 × 10(7) and 3.2 × 10(7) respectively. The level of total coliform, fecal coliform and Escherichia coli bacteria contamination in all the vegetable samples however declined as the distance between the main water source (Wiwi River) and farms increases. Nonetheless, all contamination levels were well above acceptable standards, and could therefore pose serious public health risks to consumers. Increased education and supervision of farmers, as well as public health and food hygiene education of consumers, are critical to reducing on-farm vegetable contamination and the health risks associated with consumption of such vegetables.
Masiello, S N; Martin, N H; Trmčić, A; Wiedmann, M; Boor, K J
2016-01-01
The presence of coliform bacteria in pasteurized fluid milk typically indicates that product contamination occurred downstream of the pasteurizer, but it may also indicate pasteurization failure. Although coliform detection is frequently used as a hygiene indicator for dairy products, our understanding of the taxonomic and phenotypic coliform diversity associated with dairy products is surprisingly limited. Therefore, using Petrifilm Coliform Count plates (3M, St. Paul, MN), we isolated coliforms from high-temperature, short-time (HTST)-pasteurized fluid milk samples from 21 fluid milk processing plants in the northeast United States. Based on source information and initial characterization using partial 16S rDNA sequencing, 240 nonredundant isolates were obtained. The majority of these isolates were identified as belonging to the genera Enterobacter (42% of isolates), Hafnia (13%), Citrobacter (12%), Serratia (10%), and Raoultella (9%); additional isolates were classified into the genera Buttiauxella, Cedecea, Kluyvera, Leclercia, Pantoea, and Rahnella. A subset of 104 representative isolates was subsequently characterized phenotypically. Cold growth analysis in skim milk broth showed that all isolates displayed at least a 2-log increase over 10 d at 6°C; the majority of isolates (n=74) displayed more than a 5-log increase. In total, 43% of the representative isolates displayed lipolysis when incubated on spirit blue agar at 6°C for 14 d, whereas 71% of isolates displayed proteolysis when incubated on skim milk agar at 6°C for 14 d. Our data indicate that a considerable diversity of coliforms is found in HTST-pasteurized fluid milk and that a considerable proportion of these coliforms have phenotypic characteristics that will allow them to cause fluid milk spoilage. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Fecal coliform and Escherichia coli bacteria in the St. Croix National Scenic Riverway, Summer 1999
Kroening, Sharon E.
1999-01-01
Fecal coliform and Escherichia coli (E. coli) concentrations were determined in the St. Croix National Scenic Riverway to assess whether pathogenic organisms pose a potential problem for recreational use. Samples were collected from May through September 1999 at 22 locations on the St. Croix and Namekagon Rivers. No concentrations exceeded water-quality criteria or standards set by the U.S. Environmental Protection Agency or the states of Minnesota and Wisconsin. Maximum fecal coliform and E. coli concentrations were measured in the St. Croix River at St. Croix Falls, Wisconsin. Median fecal coliform and E. coli concentrations were greater in the St. Croix River near Woodland Corner, Wisconsin, and at Marine on St. Croix, Minnesota than at other locations sampled. There were no consistent short-term variations in fecal coliform or E. coli concentrations during the summer period or any significant relations between concentrations and stream discharge, based on these results.
Fernández-Rendón, Carlos L; Barrera-Escorcia, Guadalupe
2013-01-01
The need to separate bacteria from sediment in order to appropriately count them has led to test the efficacy of different techniques. In this research, traditional techniques such as manual shaking, homogenization, ultrasonication, and surfactant are compared. Moreover, the possibility of using a set of enzymes (pancreatine) and an antibiotic (ampicillin) for sediment coliform extraction is proposed. Samples were obtained from Xochimilco Lake in Mexico City. The most probable number of coliform bacteria was determined after applying the appropriate separation procedure. Most of the techniques tested led to numbers similar to those of the control (manual shaking). Only with the use of ampicillin, a greater total coliform concentration was observed (Mann-Whitney, z = 2.09; p = 0.03). It is possible to propose the use of ampicillin as a technique for total coliform extraction; however, it is necessary to consider sensitivity of bacteria to the antibiotic.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-14
... Hwy Fecal Coliform. to entrance of White Bayou (East Baton Rouge Parish) (Scenic). 040103 Comite River--Entrance of White Fecal Coliform. Bayou to Amite River. 040201 Bayou Manchac--Headwaters to Fecal Coliform... Blind River--From Amite River TSS. Diversion Canal to mouth at Lake Maurepas (Scenic). 040903 Bayou Cane...
Hagler, A N; Rosa, C A; Morais, P B; Mendonça-Hagler, L C; Franco, G M; Araujo, F V; Soares, C A
1993-10-01
Yeasts and coliform bacteria were isolated from water that accumulated in the central cups and adjacent leaf axilae of two bromeliads, Neoregelia cruenta of a coastal sand dune and Quesnelia quesneliana of a mangrove ecosystem near the city of Rio de Janeiro, Brazil. The mean total coliform counts were above 10,000 per 100 mL for waters of both plants, but the mean fecal coliform counts were only 74 per 100 mL for Q. quesneliana and mostly undetected in water from N. cruenta. Of 90 fecal coliform isolates, 51 were typical of Escherichia coli in colony morphology and indol, methyl red, Volges-Proskauer, and citrate (IMViC) tests. Seven representatives of the typical E. coli cultures were identified as this species, but the identifications of nine other coliform bacteria were mostly dubious. The yeast community of N. cruenta was typical of plant surfaces with basidiomycetous yeasts anamorphs, and the black yeast Aureobasidium pullulans was prevalent. Quesnelia quesneliana had a substantial proportion of ascomycetous yeasts and their anamorphs, including a probable new biotype of Saccharomyces unisporus. Our results suggested that the microbial communities in bromeliad waters are typically autochtonous and not contaminants.
Laboratory investigation of drinking water sources of Kangra, Himachal Pradesh.
Thakur, S D; Panda, A K
2012-06-01
A total of 70 drinking water sources including piped water supply (n = 36), ground water sources (n = 24, hand pumps and bore wells) and natural water sources (n = 10, springs/step-wells) from various parts of district Kangra, Himachal Pradesh were investigated for their suitability for drinking purpose by presumptive coliform test. Three samples were collected from each source during different parts of the year. Piped water sources (91.7%) were most contaminated followed by natural water sources (90%) and ground water sources (62.5%). 70.5% of the total water samples (n = 210) were positive for coliforms. All the three samples from 8.3% (n = 3), 37.5% (n = 9) and 10% (n = 1) piped water, ground water and natural sources respectively, were negative for coliform organisms. A variety of organisms including Proteus, Klebsiella, Citrobacter, Escherichia coli (E. coli), Pasteurella, Enterobacter and Serratia liquefaciens were isolated from water samples positive for coliforms in presumptive coliform test. Thermo-tolerant coliform organisms; Escherichia coli, Citrobacter, Klebsiella and Enterobacter were 71.2% (n = 52) of the total bacterial isolations. These findings suggest absence of adequate treatment and disinfection of the water sources supplying drinking water in district Kangra.
Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A
1986-01-01
A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953
Derlet, Robert W; Carlson, James R
2004-01-01
To determine the prevalence of coliform and potentially pathogenic bacteria in remote backcountry alpine lakes and streams of national parks in the Sierra Nevada mountains. Water was sampled at 55 predetermined lakes and streams that would stratify the risk, based on sites used by backpackers, sites used by pack animals, and uncontaminated wild areas. Sites were distributed among Kings Canyon (15), Sequoia (17), and Yosemite (23). Water was collected using Millipore bacterial samplers, which provided specific counts of coliform and other bacteria in each water sample and also served as a transport media from the wilderness to the laboratory. On return to the laboratory, bacteria were harvested from the samplers and subjected to specific identification and qualitative analysis using standard microbiology techniques for the analysis of water. Coliform bacteria were detected in 22 of the 55 sites. All of these sites were below areas used by backpackers or pack animals. Thirty-three sites were free of coliforms. These sites included both those used lightly by backpackers and those with no human or domestic animal use. All samples contained expected amounts of normal aquatic bacteria including Pseudomonas, Rahnella aquatilis, Serratia spp, and nonpathogenic species of Yersinia. Most sampling sites in these national parks are free of coliform or pathogenic organisms. Low levels of coliform bacteria are found in some bodies of water where the watershed has been affected by human or pack animal travel.
Immunologic Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins
1979-01-15
Animal, Resources, National Academy of Sciences National Research Council. -. - L S~- A - - -7- PUBLICATIONS 1. Klipstein FA, Engert RF: Immunological... Engert RF: Immunological relationship of different preparations of coliform enterotoxins. Infec Immun 21:771, 1978 3. Klipstein FA, Engert RF...Reversal of jejunal water secretion by glucose in rats exposed to coliform enterotoxins. Gastroenterology 75:255, 1978 4. Klipstein FA, Rowe B, Engert RF
Ghosh, Anuradha; Zurek, Ludek
2015-03-01
House flies are a common pest at food animal facilities, including cattle feedlots. Previously, house flies were shown to play an important role in the ecology of Escherichia coli O157:H7; house flies in cattle feedlots carried this zoonotic pathogen and were able to contaminate cattle through direct contact and/or by contamination of drinking water and feed. Because house flies aggregate in large numbers on fresh ( # 6 h) steam-flaked corn (FSFC) used in cattle feed, the aim of this study was to assess FSFC in a cattle feedlot as a potentially important site of fecal coliform contamination by house flies. House flies and FSFC samples were collected, homogenized, and processed for culturing of fecal coliforms on membrane fecal coliform agar. Selected isolates were identified by 16S rRNA gene sequencing, and representative isolates from each phylogenetic group were genotyped by pulsed-field gel electrophoresis. Fecal coliforms were undetectable in FSFC shortly (0 h) after flaking; however, in summer, after 4 to 6 h, the concentrations of fecal coliforms ranged from 1.9 × 10(3) to 3.7 × 10(4) CFU/g FSFC (mean, 1.1 ± 3.0 × 10(4) CFU/g). House flies from FSFC carried between 7.6 × 10(2) and 4.1 × 10(6) CFU of fecal coliforms per fly (mean, 6.0 ± 2.3 × 10(5) CFU per fly). Fecal coliforms were represented by E. coli (85.1%), Klebsiella spp. (10.6%), and Citrobacter spp. (4.3%). Pulsed-field gel electrophoresis demonstrated clonal matches of E. coli and Klebsiella spp. between house flies and FSFC. In contrast, in winter and in the absence of house flies, the contamination of corn by fecal coliforms was significantly (∼10-fold) lower. These results indicate that FSFC is an important site for bacterial contamination by flies and possible exchange of E. coli and other bacteria among house flies. Further research is needed to evaluate the potential use of screens or blowers to limit the access of house flies to FSFC and therefore their effectiveness in preventing bacterial contamination.
Concentrations of fecal coliform bacteria in creeks, Anchorage, Alaska, August and September 1998
Dorava, Joseph M.; Love, Andra
1999-01-01
Water samples were collected from five creeks in undeveloped, semi-developed, and developed areas of Anchorage, Alaska, during August and September 1998 to determine concentrations of fecal coliform bacteria. In undeveloped areas of Ship, Chester, and Campbell Creeks, and the semi-developed area of Rabbit Creek, concentrations of fecal coliform bacteria ranged from less than 1 to 16 colonies per 100 milliliters of water. In the semi-developed area of Little Rabbit Creek, concentrations ranged from 30 to 860 colonies per 100 milliliters of water. In developed areas of the creeks, concentrations of fecal coliform bacteria ranged from 6 to 80 colonies per 100 milliliters of water.
Description and field test of an in situ coliform monitoring system
NASA Technical Reports Server (NTRS)
Grana, D. C.; Wilkins, J. R.
1979-01-01
A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.
Chlorine disinfection of grey water for reuse: effect of organics and particles.
Winward, Gideon P; Avery, Lisa M; Stephenson, Tom; Jefferson, Bruce
2008-01-01
Adequate disinfection of grey water prior to reuse is important to prevent the potential transmission of disease-causing microorganisms. Chlorine is a widely utilised disinfectant and as such is a leading contender for disinfection of grey water intended for reuse. This study examined the impact of organics and particles on chlorine disinfection of grey water, measured by total coliform inactivation. The efficacy of disinfection was most closely linked with particle size. Larger particles shielded total coliforms from inactivation and disinfection efficacy decreased with increasing particle size. Blending to extract particle-associated coliforms (PACs) following chlorine disinfection revealed that up to 91% of total coliforms in chlorinated grey water were particle associated. The organic concentration of grey water affected chlorine demand but did not influence the disinfection resistance of total coliforms when a free chlorine residual was maintained. Implications for urban water reuse are discussed and it is recommended that grey water treatment systems target suspended solids removal to ensure removal of PACs prior to disinfection.
Firth, Jacqueline; Balraj, Vinohar; Muliyil, Jayaprakash; Roy, Sheela; Rani, Lilly Michael; Chandresekhar, R.; Kang, Gagandeep
2010-01-01
To assess water contamination and the relative effectiveness of three options for point-of-use water treatment in South India, we conducted a 6-month randomized, controlled intervention trial using chlorine, Moringa oleifera seeds, a closed valved container, and controls. One hundred twenty-six families participated. Approximately 70% of public drinking water sources had thermotolerant coliform counts > 100/100 mL. Neither M. oleifera seeds nor containers reduced coliform counts in water samples from participants' homes. Chlorine reduced thermotolerant coliform counts to potable levels, but was less acceptable to participants. Laboratory testing of M. oleifera seeds in water from the village confirmed the lack of reduction in coliform counts, in contrast to the improvement seen with Escherichia coli seeded distilled water. This discrepancy merits further study, as M. oleifera was effective in reducing coliform counts in other studies and compliance with Moringa use in this study was high. PMID:20439952
Firth, Jacqueline; Balraj, Vinohar; Muliyil, Jayaprakash; Roy, Sheela; Rani, Lilly Michael; Chandresekhar, R; Kang, Gagandeep
2010-05-01
To assess water contamination and the relative effectiveness of three options for point-of-use water treatment in South India, we conducted a 6-month randomized, controlled intervention trial using chlorine, Moringa oleifera seeds, a closed valved container, and controls. One hundred twenty-six families participated. Approximately 70% of public drinking water sources had thermotolerant coliform counts > 100/100 mL. Neither M. oleifera seeds nor containers reduced coliform counts in water samples from participants' homes. Chlorine reduced thermotolerant coliform counts to potable levels, but was less acceptable to participants. Laboratory testing of M. oleifera seeds in water from the village confirmed the lack of reduction in coliform counts, in contrast to the improvement seen with Escherichia coli seeded distilled water. This discrepancy merits further study, as M. oleifera was effective in reducing coliform counts in other studies and compliance with Moringa use in this study was high.
Immunologic Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins
1980-01-15
PUBLICATIONS Supported by Contract No. DAMD 17-77-C-7032 1. Klipstein FA, Engert RF: Immunological interrelationships between cholera toxin and the...heat-labile and heat-stable enterotoxins of coliform bacteria. Infec Immun 18:110, 1977 2. Klipstein FA, Engert RF: Immunological relationship of...different preparations of coliform enterotoxins. Infec Immun 21:771, 1978 3. Klipstein FA, Engert RF: Reversal of jejunal water secretion by glucose in
Immunological Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins
1981-01-01
FA, Engert RF: Immunological interrelationships between cholera toxin and the heat-labile and heat-stable enterotoxins of coliforn, bacteria. Infec...Irnmun 18:110, 1977 2. Klipstein FA, Engert RF: Immunological relaticnsh~p of different preparations of coliform enterotoxins. Infec Immun 21:771, 1918...3 Klipstein FA, Engert RF: Reversal of jejunal water secretion by glucose in rats exposed to coliform enterotoxcins. Gastroenterology 75:255, 1978 4
Increasing Efficiency of Fecal Coliform Testing Through EPA-Approved Alternate Method Colilert*-18
NASA Technical Reports Server (NTRS)
Cornwell, Brian
2017-01-01
The 21 SM 9221 E multiple-tube fermentation method for fecal coliform analysis requires a large time and reagent investment for the performing laboratory. In late 2010, the EPA approved an alternative procedure for the determination of fecal coliforms designated as Colilert*-18. However, as of late 2016, only two VELAP-certified laboratories in the Commonwealth of Virginia have been certified in this method.
Farkas, Anca; Crăciunaş, Cornelia; Chiriac, Cecilia; Szekeres, Edina; Coman, Cristian; Butiuc-Keul, Anca
2016-11-01
This study investigates the role of coliforms in the carriage of class 1 integron and biocide resistance genes in a drinking water treatment plant and explores the relationship between the carriage of such genes and the biofouling abilities of the strain. The high incidence of class 1 integron and biocide resistance genes (33.3 % of the isolates) highlights the inherent risk of genetic contamination posed by coliform populations during drinking water treatment. The association between the presence of intI1 gene and qac gene cassettes, especially qacH, was greater in biofilm cells. In coliforms recovered from biofilms, a higher frequency of class 1 integron elements and higher diversity of genetic patterns occurred, compared to planktonic cells. The coliform isolates under the study proved to mostly carry non-classical class 1 integrons lacking the typical qacEΔ1/sul1 genes or a complete tni module, but bearing the qacH gene. No link was found between the carriage of integron genes and the biofouling degree of the strain, neither in aerobic or in anaerobic conditions. Coliform bacteria isolated from established biofilms rather adhere in oxygen depleted environments, while the colonization ability of planktonic cells is not significantly affected by oxygen availability.
Assessing the sources of high fecal coliform levels at an urban tropical beach
Davino, Aline Mendonça Cavalcante; de Melo, Milena Bandeira; Caffaro, Roberto Augusto
2015-01-01
Recreational water quality is commonly assessed by microbial indicators such as fecal coliforms. Maceió is the capital of Alagoas state, located in tropical northeastern Brazil. Its beaches are considered as the most beautiful urban beaches in the country. Jatiúca Beach in Maceió was found to be unsuitable for bathing continuously during the year of 2011. The same level of contamination was not observed in surrounding beaches. The aim of this study was to initiate the search for the sources of these high coliform levels, so that contamination can be eventually mitigated. We performed a retrospective analysis of historical results of fecal coliform concentrations from 2006 to 2012 at five monitoring stations located in the study region. Results showed that Jatiúca Beach consistently presented the worst quality among the studied beaches. A field survey was conducted to identify existing point and non-point sources of pollution in the area. Monitoring in the vicinity of Jatiúca was spatially intensified. Fecal coliform concentrations were categorized according to tide range and tide stage. A storm drain located in northern Jatiúca was identified as the main point source of the contamination. However, fecal coliform concentrations at Jatiúca were high during high tides and spring tides even when this point source was inactive (no rainfall). We hypothesize that high fecal coliform levels in Jatiúca Beach may also be caused by aquifer contamination or, more likely, from tide washing of contaminated sand. Both of these hypotheses will be further investigated. PMID:26691459
Assessing the sources of high fecal coliform levels at an urban tropical beach.
Davino, Aline Mendonça Cavalcante; de Melo, Milena Bandeira; Caffaro Filho, Roberto Augusto
2015-01-01
Recreational water quality is commonly assessed by microbial indicators such as fecal coliforms. Maceió is the capital of Alagoas state, located in tropical northeastern Brazil. Its beaches are considered as the most beautiful urban beaches in the country. Jatiúca Beach in Maceió was found to be unsuitable for bathing continuously during the year of 2011. The same level of contamination was not observed in surrounding beaches. The aim of this study was to initiate the search for the sources of these high coliform levels, so that contamination can be eventually mitigated. We performed a retrospective analysis of historical results of fecal coliform concentrations from 2006 to 2012 at five monitoring stations located in the study region. Results showed that Jatiúca Beach consistently presented the worst quality among the studied beaches. A field survey was conducted to identify existing point and non-point sources of pollution in the area. Monitoring in the vicinity of Jatiúca was spatially intensified. Fecal coliform concentrations were categorized according to tide range and tide stage. A storm drain located in northern Jatiúca was identified as the main point source of the contamination. However, fecal coliform concentrations at Jatiúca were high during high tides and spring tides even when this point source was inactive (no rainfall). We hypothesize that high fecal coliform levels in Jatiúca Beach may also be caused by aquifer contamination or, more likely, from tide washing of contaminated sand. Both of these hypotheses will be further investigated.
Molecular method for detection of total coliforms in drinking water samples.
Maheux, Andrée F; Boudreau, Dominique K; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G; Rodriguez, Manuel J
2014-07-01
This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Molecular Method for Detection of Total Coliforms in Drinking Water Samples
Boudreau, Dominique K.; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G.; Rodriguez, Manuel J.
2014-01-01
This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. PMID:24771030
Izumi, Hidemi; Inoue, Ayano
2018-02-02
The extent of sublethally injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, was evaluated during storage in air and high CO 2 controlled atmospheres (5%, 10%, and 15%) at 5°C and 10°C using the thin agar layer (TAL) method. Sublethally injured coliform bacteria on nonrinsed shredded cabbage were either absent or they were injured at a 64-65% level when present. Rinsing of shredded cabbage with electrolyzed water containing 25ppm available chlorine reduced the coliform counts by 0.4 to 1.1 log and caused sublethal injury ranging from 42 to 77%. Pantoea ananatis was one of the species injured by chlorine stress. When shredded cabbage, nonrinsed or rinsed with electrolyzed water, was stored in air and high CO 2 atmospheres at 5°C for 7days and 10°C for 5days, coliform counts on TAL plates increased from 3.3-4.5 to 6.5-9.0 log CFU/g during storage, with the increase being greater at 10°C than at 5°C. High CO 2 of 10% and 15% reduced the bacterial growth on shredded cabbage during storage at 5°C. Although injured coliform bacteria were not found on nonrinsed shredded cabbage on the initial day, injured coliforms at a range of 49-84% were detected on samples stored in air and high CO 2 atmospheres at 5°C and 10°C. Injured cells were detected more frequently during storage at both temperatures irrespective of the CO 2 atmosphere when shredded cabbage was rinsed with electrolyzed water. These results indicated that injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, exhibited different degrees of injury during storage regardless of the CO 2 atmosphere and temperature tested. Copyright © 2017 Elsevier B.V. All rights reserved.
Water quality in three creeks in the backcountry of Grand Teton National Park, USA
Farag, A.M.; Goldstein, J.N.; Woodward, D.F.
2001-01-01
This study was conducted in Grand Teton National Park during the summers of 1996 and 1997 to investigate the water quality in two high human use areas: Garnet Canyon and lower Cascade Canyon. To evaluate the water quality in these creeks, fecal coliform, Giardia lamblia, coccidia, and microparticulates were measured in water samples. No evidence of fecal coliform, Giardia lamblia, or coccidia, was found in Garnet Creek. The water quality and general water chemistry of Garnet Creek was similar to the reference site. No Giardia lamblia or coccidia were found in Cascade Creek, but fecal coliforms were present. The isolated colonies of Escherichia coli from Cascade Creek matched the ribosome patterns of avian, deer, canine, elk, rodent, and human coliforms.
Method for detecting coliform organisms
NASA Technical Reports Server (NTRS)
Nishioka, K.; Nibley, D. A.; Jeffers, E. L.; Brooks, R. L. (Inventor)
1983-01-01
A method and apparatus are disclosed for determining the concentration of coliform bacteria in a sample. The sample containing the coliform bacteria is cultured in a liquid growth medium. The cultured bacteria produce hydrogen and the hydrogen is vented to a second cell containing a buffer solution in which the hydrogen dissolves. By measuring the potential change in the buffer solution caused by the hydrogen, as a function of time, the initial concentration of bacteria in the sample is determined. Alternatively, the potential change in the buffer solution can be compared with the potential change in the liquid growth medium to verify that the potential change in the liquid growth medium is produced primarily by the hydrogen gas produced by the coliform bacteria.
Bacterial Pollution Indicators in the Intestinal Tract of Freshwater Fish
Geldreich, Edwin E.; Clarke, Norman A.
1966-01-01
A study was made of the occurrence, distribution, and persistence of coliforms, fecal coliforms, and fecal streptococci in the intestinal tract of freshwater fish. A total of 132 fish representing 14 different species were used in various phases of these experiments. Examination of the intestinal contents of 78 fish from moderately polluted sections of the Little Miami River indicated that fecal coliform densities were lowest in bluegills (less than 20 per gram) and highest in catfish (1,090,000 per gram). Levels of fecal streptococci for these two species were 220 and 240,000 per gram, respectively. The occurrence of fecal coliforms in fish caught in this stream reflected the warm-blooded-animal-pollution level of the water. All fish used in this phase of the study were caught during July, August, and September when the water temperatures were between 13 and 18 C. The fate of fecal coliforms and Streptococcus faecalis in the fish intestine indicated that these organisms can probably survive and multiply when fish and water temperatures are 20 C or higher, but only when the organisms are retained in the gut for periods beyond 24 hr. Based on the biochemical reactions for 3,877 coliform strains isolated from 132 freshwater fish of 14 different species, 91.4% of all strains were composed of five IMViC types. In a similar study of the biochemical reactions of 850 streptococci isolated from the intestinal tract of 55 freshwater fish, the predominant strains included S. faecalis and various closely associated biotypes. No consistently recurring pattern for either coliforms or streptococci could be developed to identify species of fish investigated. The composition of the intestinal flora is, however, related in varying degree to the level of contamination of water and food in the environment. Images Fig. 1 Fig. 2 PMID:6008184
Mugnai, Riccardo; Sattamini, Ana; Albuquerque dos Santos, José Augusto; Regua-Mangia, Adriana Hamond
2015-01-01
The Hyporheic Zone is among the most important interstitial freshwater habitats, but the relationship between biotic and abiotic factors in this zone remains under-explored. Enterobacteria were expected to be present, but no specific studies had ever confirmed this prediction. The aim of this study was, therefore, to evaluate the total coliforms, Escherichia coli and Salmonella spp. in hyporheic water and to determine the relationship of the physical, chemical and environmental factors at different depths in a rainforest stream. To this end, thirty-six water samples were collected at three depths in sites located in the first, second and third orders in diverse substrates. The total coliforms, Escherichia coli and Salmonella sp. were evaluated in terms of their CFU/ml. In the interstitial samples, coliforms were detected in 100% of the samples. The total coliform counts had higher values at intermediate depths, while E. coli and Salmonella spp. instead had higher values at intermediate and large depths, often reaching or exceeding the values of the surface samples. Our results revealed that Salmonella spp. and the coliforms have different microhabitat preferences. Salmonella spp. and coliform species prefer deposition areas, such as lateral sides of pools, curves and bars, but they have a tendency to distribute into different depths, likely due to temperature differences. Salmonella spp. prefer compact substrata, with fewer fluids passing through and with upwelling areas with lower oxygen inflow. The coliform species showed the opposite preference. Our results suggest that bacterial variation is related to environmental factors and physical-chemical parameters within the HZ and may play a key role in the microbial diversity and distribution in these ecosystems. PMID:26067288
Entry, James A; Leytem, April B; Verwey, Sheryl
2005-11-01
We measured Escherichia coli, Enterococcus spp. and fecal coliform numbers in soil and on fresh potato skins after addition of solid dairy manure and dairy compost with and without alum (Al(2)(SO(4))(3)) treatment 1, 7, 14, 28, 179 and 297 days after application. The addition of dairy compost or solid dairy manure at rates to meet crop phosphorus uptake did not consistently increase E. coli and Enterococcus spp. and fecal coliform bacteria in the soil. We did not detect E. coli in any soil sample after the first sampling day. Seven, 14, 28, 179 and 297 days after solid dairy waste and compost and alum were applied to soil, alum did not consistently affect Enterococcus spp. and fecal coliform bacteria in the soil. We did not detect E. coli in any soil, fresh potato skin or potato wash-water at 214 days after dairy manure or compost application regardless of alum treatment. Dairy compost or solid dairy manure application to soil at rates to meet crop phosphorus uptake did not consistently increase Enterococcus spp. and fecal coliform numbers in bulk soil. Solid dairy manure application to soil at rates to meet crop phosphorus uptake, increased Enterococcus spp. and fecal coliform numbers in potato rhizosphere soil. However, fresh potato skins had higher Enterococcus spp. and fecal coliform numbers when solid dairy manure was added to soil compared to compost, N and P inorganic fertilizer and N fertilizer treatments. We did not find any E. coli, Enterococcus or total coliform bacteria on the exterior of the tuber, within the peel or within a whole baked potato after microwave cooking for 5 min.
Izumi, Hidemi; Nakata, Yuji; Inoue, Ayano
2016-10-01
Chemical sanitizers may induce no injury (bacteria survive), sublethal injury (bacteria are injured), or lethal injury (bacteria die). The proportion of coliform bacteria that were injured sublethally by chlorine and fungicide mixed with agricultural water (pond water), which was used to dilute the pesticide solution, was evaluated using the thin agar layer (TAL) method. In pure cultures of Enterobacter cloacae , Escherichia coli , and E. coli O157:H7 (representing a human pathogen), the percentage of chlorine-injured cells was 69 to 77% for dilute electrolyzed water containing an available chlorine level of 2 ppm. When agricultural water was mixed with electrolyzed water, the percentage of injured coliforms in agricultural water was 75%. The isolation and identification of bacteria on TAL and selective media suggested that the chlorine stress caused injury to Enterobacter kobei . Of the four fungicide products tested, diluted to their recommended concentrations, Topsin-M, Sumilex, and Oxirane caused injury to coliform bacteria in pure cultures and in agricultural water following their mixture with each pesticide, whereas Streptomycin did not induce any injury to the bacteria. The percentage of injury was 45 to 97% for Topsin-M, 80 to 87% for Sumilex, and 50 to 97% for Oxirane. A comparison of the coliforms isolated from the pesticide solutions and then grown on either TAL or selective media indicated the possibility of fungicide-injured Rahnella aquatilis , Yersinia mollaretii , and E. coli . These results suggest the importance of selecting a suitable sanitizer and the necessity of adjusting the sanitizer concentration to a level that will kill the coliforms rather than cause sanitizer-induced cell injury that can result in the recovery of the coliforms.
Greve, Josephine D; Zietlow, Mark S; Miller, Kevin M; Ellingson, Jay L E
2015-09-01
A total of 720 whole, romaine lettuce heads were purchased from retail locations in the Upper Midwest and assessed for coliform and Escherichia coli contamination and for the presence of E. coli O157:H7. During a 16-month period (August 2010 through December 2011), coliform and E. coli counts were enumerated on Petrifilm, and the presence of E. coli O157:H7 and the virulence gene eae was evaluated by real-time PCR (qPCR). Over half (400 of 720) of the lettuce samples were processed with an immunomagnetic separation step before the qPCR assay. All retail lettuce samples were negative for E. coli O157:H7 when tested with the R.A.P.I.D. LT qPCR targeting a region of the O-antigen, and only two (0.28%) were positive for the eae gene when tested with LightCycler qPCR. On Petrifilm, coliform counts of most lettuce samples (96.4%) were between <10(1) and 10(3) CFU/g, and E. coli counts for nearly all lettuce samples (98.2%) were <10(1) CFU/g. No seasonal trend in coliform and E. coli counts was observed throughout the examination period nor was a difference in coliform counts observed between packaged and nonpackaged lettuce heads. These results contribute to the limited recorded data and understanding of microbial contamination of whole romaine lettuce heads purchased from retail locations, specifically revealing the absence of E. coli O157:H7 and low levels of contamination with coliforms and other E. coli strains.
Metropolitan Spokane Region Water Resources Study. Appendix A. Surface Water
1976-01-01
is adequate. Cnly phenols and detergents are reported in the pollutants category and no bacteriological tests are made. Since none of the other sources...Coliform, MPN Conf No/100ml 31507 Total Coliform, MPN Comp No/lO0ml 31615 Fecal Coliform, MPNECmED No/100ml 32730 Phenols ug/1l 38260 MBAS mg/l 70507...Oil & Grease, Pesticides, I Surfactants, Sulfite Waste Liquor, Phenols WATER RESOURCES STUDY METROPOLITAN SPOKANE REGION GROUPING OF WATER QUALITY
NASA Astrophysics Data System (ADS)
Riyanto; Agustiningsih, W. A.
2018-04-01
Disinfection of coliform and E. Coli in water has been performed by electrolysis using carbon electrodes. Carbon electrodes were used as an anode and cathode with a purity of 98.31% based on SEM-EDS analysis. This study was conducted using electrolysis powered by electric field using carbon electrode as the anode and cathode. Electrolysis method was carried out using variations of time (30, 60, 90, 120 minutes at a voltage of 5 V) and voltage (5, 10, 15, 20 V for 30 minutes) to determine the effect of the disinfection of the bacteria. The results showed the number of coliform and E. coli in water before and after electrolysis was 190 and 22 MPN/100 mL, respectively. The standards quality of drinking water No. 492/Menkes/Per/IV/2010 requires the zero content of coliform and E. Coli. Electrolysis with the variation of time and potential can reduce the number of coliforms and E. Coli but was not in accordance with the standards. The effect of hydrogen peroxide (H2O2) to the electrochemical disinfection was determined using UV-Vis spectrophotometer. The levels of H2O2 formed increased as soon after the duration of electrolysis voltage but was not a significant influence to the mortality of coliform and E.coli.
The presence-absence coliform test for monitoring drinking water quality.
Rice, E W; Geldreich, E E; Read, E J
1989-01-01
The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663
Kämpfer, Peter; Nienhüser, Anita; Packroff, Gabriele; Wernicke, Frank; Mehling, Arnd; Nixdorf, Katja; Fiedler, Stefanie; Kolauch, Claudia; Esser, Michael
2008-07-01
The accuracy of a traditional method (lactose utilization with acid and gas production) for the detection of coliform bacteria and E. coli was tested in comparison with method ISO 9308-1 (based on acid formation from lactose) and the Colilert-18 system (detection of beta-galactosidase). A total of 345 isolates were identified after isolation from water samples using API 20E strips. The Colilert-18 led to the highest number of positive findings (95% of the isolates were assigned to coliforms), whereas the ISO-9308-1 method resulted only in 29% coliform findings. With the traditional method only 15% were rated positive. Most of the isolates were identified by the API 20E system as Enterobacter spp. (species of the Enterobacter cloacae complex), Serratia spp., Citrobacter spp.and Klebsiella spp.; but species identification remained vague in several cases. A more detailed identification of 126 pure cultures by using 16S rRNA gene sequence analysis and analysis of the hsp60 gene resulted in the identification of Enterobacter nimipressuralis, E. amnigenus, E. asburiae, E. hormaechei, and Serratia fonticola as predominat coliforms. These species are beta-galactosidase positive, but show acid formation from lactose often after a prolonged incubation time. They are often not of fecal origin and may interfere with the ability to accurately detect coliforms of fecal origin.
Modeling seasonal variability of fecal coliform in natural surface waters using the modified SWAT
NASA Astrophysics Data System (ADS)
Cho, Kyung Hwa; Pachepsky, Yakov A.; Kim, Minjeong; Pyo, JongCheol; Park, Mi-Hyun; Kim, Young Mo; Kim, Jung-Woo; Kim, Joon Ha
2016-04-01
Fecal coliforms are indicators of pathogens and thereby, understanding of their fate and transport in surface waters is important to protect drinking water sources and public health. We compiled fecal coliform observations from four different sites in the USA and Korea and found a seasonal variability with a significant connection to temperature levels. In all observations, fecal coliform concentrations were relatively higher in summer and lower during the winter season. This could be explained by the seasonal dominance of growth or die-off of bacteria in soil and in-stream. Existing hydrologic models, however, have limitations in simulating the seasonal variability of fecal coliform. Soil and in-stream bacterial modules of the Soil and Water Assessment Tool (SWAT) model are oversimplified in that they exclude simulations of alternating bacterial growth. This study develops a new bacteria subroutine for the SWAT in an attempt to improve its prediction accuracy. We introduced critical temperatures as a parameter to simulate the onset of bacterial growth/die-off and to reproduce the seasonal variability of bacteria. The module developed in this study will improve modeling for environmental management schemes.
Assessment of On-site sanitation system on local groundwater regime in an alluvial aquifer
NASA Astrophysics Data System (ADS)
Quamar, Rafat; Jangam, C.; Veligeti, J.; Chintalapudi, P.; Janipella, R.
2017-12-01
The present study is an attempt to study the impact of the On-site sanitation system on the groundwater sources in its vicinity. The study has been undertaken in the Agra city of Yamuna sub-basin. In this context, sampling sites (3 nos) namely Pandav Nagar, Ayodhya Kunj and Laxmi Nagar were selected for sampling. The groundwater samples were analyzed for major cations, anions and faecal coliform. Critical parameters namely chloride, nitrate and Faecal coliform were considered to assess the impact of the On-site sanitation systems. The analytical results shown that except for chloride, most of the samples exceeded the Bureau of Indian Standard limits for drinking water for all the other analyzed parameters, i.e., nitrate and faecal coliform in the first two sites. In Laxmi Nagar, except for faecal coliform, all the samples are below the BIS limits. In all the three sites, faecal coliform was found in majority of the samples. A comparison of present study indicates that the contamination of groundwater in alluvial setting is less as compared to hard rock where On-site sanitation systems have been implemented.
Inactivation of indigenous coliform bacteria in unfiltered surface water by ultraviolet light.
Cantwell, Raymond E; Hofmann, Ron
2008-05-01
This study examined the potential for naturally occurring particles to protect indigenous coliform from ultraviolet (UV) disinfection in four surface waters. Tailing in the UV dose-response curve of the bacteria was observed in 3 of the 4 water samples after 1.3-2.6-log of log-linear inactivation, implying particle-related protection. The impact of particles was confirmed by comparing coliform UV inactivation data for parallel filtered (11 microm pore-size nylon filters) and unfiltered surface water. In samples from the Grand River (UVT: 65%/cm; 5.4 nephelometric turbidity units (NTU)) and the Rideau Canal (UVT: 60%/cm; 0.84 NTU), a limit of approximately 2.5 log inactivation was achieved in the unfiltered samples for a UV dose of 20 mJ/cm2 while both the filtered samples exhibited >3.4-log inactivation of indigenous coliform bacteria. The results suggest that particles as small as 11 microm, naturally found in surface water with low turbidity (<3NTU), are able to harbor indigenous coliform bacteria and offer protection from low-pressure UV light.
Devi, Rani; Alemayehu, Esayas; Singh, Vijender; Kumar, Ashok; Mengistie, Embialle
2008-05-01
An attempt was made to investigate the removal of fluoride, arsenic and coliform bacteria from drinking water using modified homemade filter media. Batch mode experimental study was conducted to test the efficiency of modified homemade filter for reduction of impurities under the operating condition of treatment time. The physico-chemical and biological analysis of water samples had been done before and after the treatment with filter media, using standard methods. Optimum operating treatment time was determined for maximum removal of these impurities by running the experiment for 2, 4, 6, 8, 10 and 12h, respectively. The maximum reduction of fluoride, arsenic and coliform bacteria in percentage was 85.60%, 93.07% and 100% and their residual values were 0.72 mg/l, 0.009 mg/l and 0 coliform cells/100ml, respectively after a treatment time of 10h. These residual values were under the permissible limits prescribed by WHO. Hence this could be a cheap, easy and an efficient technique for removal of fluoride, arsenic and coliform bacteria from drinking water.
Effect of ambient temperature storage on potable water coliform population estimations.
Standridge, J H; Delfino, J J
1983-01-01
The effect of the length of time between sampling potable water and performing coliform analyses has been a long-standing controversial issue in environmental microbiology. The issue is of practical importance since reducing the sample-to-analysis time may substantially increase costs for water analysis programs. Randomly selected samples (from those routinely collected throughout the State of Wisconsin) were analyzed for total coliforms after being held at room temperature (20 +/- 2 degrees C) for 24 and 48 h. Differences in results for the two holding times were compared with differences predicted by probability calculations. The study showed that storage of the potable water for up to 48 h had little effect on the public health significance of most samples containing more than two coliforms per 100 ml. PMID:6651296
Reibnitz, M G; Tavares, L B; García, J A
1998-01-01
Twenty cheese samples were collected at Blumenau (SC) and were submitted to analysis in order to verify the presence of fecal coliforms, Escherichia coli and Staphylococcus aureus. Among the 20 samples of cheese, analysis revealed that 70% and 20% respectively, were not within present legal specifications (Norma 001/87-DNVSA) for fecal coliforms and Escherichia coli. For Staphylococcus, 95% of the samples were not within present legal specifications.
False positive fecal coliform in biosolid samples assayed using A-1 medium.
Baker, Katherine H; Redmond, Brady; Herson, Diane S
2005-01-01
Two most probable number (MPN) methods-lauryl tryptose broth with Escherichia coli broth confirmation and direct A-1 broth incubation (A-1)--were compared for the enumeration of fecal coliform in lime-treated biosolid. Fecal coliform numbers were significantly higher using the A-1 method. Analysis of positive A-1 tubes, however, indicated that a high percentage of these were false positives. Therefore, the use of A-1 broth for 40 CFR Part 503 Pathogen Reduction (CFR, 1993) compliance testing is not recommended.
Fecal-coliform bacteria in extended-aeration plant sludge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, M.; Kester, G.; Arant, S.
1998-07-01
The concentration of fecal-coliform bacteria in sludge from extended-aeration plants was analyzed for compliance with new state and federal land application requirements. This study was initiated to determine if additional digestion would be necessary for plants to meet the new pathogen standards of less than 2 million CFU per gm of solids. Sludge was found to contain less than 2 million fecal coliform bacteria/gm of sludge as a result of a combination or aerobic digestion and/or long term storage.
Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P
2011-03-01
The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.
Climate relationships to fecal bacterial densities in Maryland shellfish harvest waters.
Leight, A K; Hood, R; Wood, R; Brohawn, K
2016-02-01
Coastal states of the United States (US) routinely monitor shellfish harvest waters for types of bacteria that indicate the potential presence of fecal pollution. The densities of these indicator bacteria in natural waters may be related to climate in several ways, including through runoff from precipitation and survival related to water temperatures. The relationship between interannual precipitation and air temperature patterns and the densities of fecal indicator bacteria in shellfish harvest waters in Maryland's portion of the Chesapeake Bay was quantified using 34 years of data (1979-2013). Annual and seasonal precipitation totals had a strong positive relationship with average fecal coliform levels (R(2) = 0.69) and the proportion of samples with bacterial densities above the FDA regulatory criteria (R(2) = 0.77). Fecal coliform levels were also significantly and negatively related to average annual air temperature (R(2) = -0.43) and the average air temperature of the warmest month (R(2) = -0.57), while average seasonal air temperature was only significantly related to fecal coliform levels in the summer. River and regional fecal coliform levels displayed a wide range of relationships with precipitation and air temperature patterns, with stronger relationships in rural areas and mainstem Bay stations. Fecal coliform levels tended to be higher in years when the bulk of precipitation occurred throughout the summer and/or fall (August to September). Fecal coliform levels often peaked in late fall and winter, with precipitation peaking in summer and early fall. Continental-scale sea level pressure (SLP) analysis revealed an association between atmospheric patterns that influence both extratropical and tropical storm tracks and very high fecal coliform years, while regional precipitation was found to be significantly correlated with the Atlantic Multidecadal Oscillation and the Pacific North American Pattern. These findings indicate that management of shellfish harvest waters should account for changes in climate conditions and that SLP patterns may be particularly important for predicting years with extremely high levels of fecal coliforms. Published by Elsevier Ltd.
Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.
Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A
2012-03-01
The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (<0.10mg/L) with the pH ranging between 5.5 and 7.3 and turbidity between 0.14-1.76 NTU. Since contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (<0.10mg/ L) in all samples as well as in both tap water and commercially bottled drinking water, with the pH ranged between 5.5-7.3, ineffective disinfection of water source as a contributing factor to such high counts of faecal coliforms in ice cubes also could not be ruled out. Therefore, a periodical, yet comprehensive check on the food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.
Clark, Melanie L.; Gamper, Merry E.
2003-01-01
A synoptic study of fecal-indicator bacteria was conducted during June and July 2000 in the Wind River, Bighorn River, and Goose Creek Basins in Wyoming as part of the U.S. Geological Survey's National Water-Quality Assessment Program for the Yellowstone River Basin. Fecal-coliform concentrations ranged from 2 to 3,000 col/100 mL (colonies per 100 milliliters) for 100 samples, and Escherichia coli concentrations ranged from 1 to 2,800 col/100 mL for 97 samples. Fecal-coliform concentrations exceeded the U.S. Environmental Protection Agency's recommended limit for a single sample for recreational contact with water in 37.0 percent of the samples. Escherichia coli concentrations exceeded the U.S. Environmental Protection Agency's recommended limit for a single sample for moderate use, full-body recreational contact with water in 38.1 percent of the samples and the recommended limit for infrequent use, full-body recreational contact with water in 24.7 percent of the samples. Fecal-indicator-bacteria concentrations varied by basin. Samples from the Bighorn River Basin had the highest median concentrations for fecal coliform of 340 col/100 mL and for Escherichia coli of 300 col/100 mL. Samples from the Wind River Basin had the lowest median concentrations for fecal coliform of 50 col/100 mL and for Escherichia coli of 62 col/100 mL. Fecal-indicator-bacteria concentrations varied by land cover. Samples from sites with an urban land cover had the highest median concentrations for fecal coliform of 540 col/100 mL and for Escherichia coli of 420 col/100 mL. Maximum concentrations for fecal coliform of 3,000 col/100 mL and for Escherichia coli of 2,800 col/100 mL were in samples from sites with an agricultural land cover. The lowest median concentrations for fecal coliform of 130 col/100 mL and for Escherichia coli of 67 col/100 mL were for samples from sites with a forested land cover. A strong and positive relation existed between fecal coliform and Escherichia coli (Spearman's Rho value of 0.976). The majority of the fecal coliforms were Escherichia coli during the synoptic study. Fecal-indicator-bacteria concentrations were not correlated to streamflow, water temperature, dissolved oxygen, pH, specific conduc-tance, and alkalinity. Fecal-indicator-bacteria concentrations were moderately correlated with turbidity (Spearman's Rho values of 0.662 and 0.640 for fecal coliform and Escherichia coli, respectively) and sediment (Spearman's Rho values of 0.628 and 0.636 for fecal coliform and Escherichia coli, respectively). Escherichia coli isolates analyzed by discriminant analysis of ribotype patterns for samples from the Bighorn River at Basin, Wyoming, and Bitter Creek near Garland, Wyoming, in the Bighorn River Basin were determined to be from nonhuman and human sources. Using a confidence interval of 90 percent, more of the isolates from both sites were classified as being from nonhuman than human sources; however, both samples had additional isolates that were classified as unknown sources. --------------------------------------------------------------------------------
33 CFR 159.53 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...
33 CFR 159.53 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...
Total Coliform Rule Distribution System Advisory Committee (TCRDSAC) Document
This document provide information about the TCRDSAC, including its charter, processes and recommendations. The Agency used the Advisory Committee recommendations to develop proposed and final rules that revised the Total Coliform Rule.
Method of Detecting Coliform Bacteria from Reflected Light
NASA Technical Reports Server (NTRS)
Vincent, Robert K. (Inventor)
2014-01-01
The present invention relates to a method of detecting coliform bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.
Revised Total Coliform Rule Lab Sampling Form
This form should be completed when a water system collects any required Revised Total Coliform Rule (RTCR) samples. It should also be used when collecting “Special” non-compliance samples for the RTCR.
Revised Total Coliform Webinar for Primacy Agencies
This webinar was created to assist Primacy Agencies in the implementation of the Revised Total Coliform Rule. It provides an overview of the requirements in the rule and implementation guidance for Primacy Agencies.
33 CFR 159.53 - General requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...
33 CFR 159.53 - General requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...
33 CFR 159.53 - General requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...
Effect of wastewater quality parameters on coliform inactivation by tin oxide anodes.
Teel, Amy L; Watts, Richard J
2018-04-16
The effect of six water quality constituents on wastewater effluent disinfection by tin oxide anodes (TOAs) was investigated in single cell laboratory reactors. Several concentrations of suspended solids, chemical oxygen demand (COD), alkalinity, ammonia-nitrogen, nitrite-nitrogen, and nitrate-nitrogen were added to media containing 10 6 total coliform bacteria mL -1 . Current was applied through the TOAs, and coliform bacteria viability was analyzed over time. Over 99.9% inactivation of coliform bacteria was found over 15 min in TOA reactors. Concentrations of the six water quality constituents typical of concentrations found in wastewaters had no effect on TOA disinfection efficacy. The results of this research demonstrate that TOAs, which could potentially be powered by solar panels, have potential as a sustainable disinfection process compared to chlorine, ozone, and ultraviolet light.
Zhuravlev, P V; Aleshnia, V V; Panasovets, O P; Morozova, A A; Artemova, T Z; Talaeva, Iu G; Zagaĭnova, A V; Gipp, E K
2012-01-01
Due to intensive anthropogenic pollution of water environment generally accepted indicators of epidemic security of water bodies - common bacteria and thermotolerant coliform bacteria do not always permit to obtain an objective characterization of bacterial contamination of tap water. From the point of view of authors the integral index - glucose positive coliform bacteria most adequately reflect the sanitary-hygienic and epidemiological situation of water bodies. In monitoring for bacterial quality of tap water it is advisable to determine glucose positive coliform bacteria, that will provide the relevance of estimation of the epidemiological safety of water use. According to the method developed by the authors the calculation of the index of population risk of acute intestinal infections occurrence in dependence on the quality of tap water in Azov and Tsimlyansk towns.
Coliform inhibition by bacteriocin-like substances in drinking water distribution systems.
Means, E G; Olson, B H
1981-01-01
Bacterial isolates from an unchlorinated potable groundwater system and a chlorinated surface water system were screened by an agar overlay method for the ability to produce bacteriocin-like substances (BLS) inhibitory to the growth of Escherichia coli, Klebsiella sp., and Enterobacter aerogenes. The production of coliform-specific BLS by noncoliform bacteria varied with the site and date of isolation as well as the genus of the producer strain. A total of 448 bacterial isolates were screened from the chlorinated system, and 22.1% produced BLS specific for at least one of the three coliforms. In the unchlorinated system, 7.9% (n = 696) possessed this ability. Flavobacterium/Moraxella comprised 57.1% of all bacteria (from both systems) producing BLS. The possibility that BLS interfere with coliform detection in standard bacteriological water quality tests is discussed. Images PMID:7027953
Hughes, Kevin A
2003-08-01
Factors affecting fecal microorganism survival and distribution in the Antarctic marine environment include solar radiation, water salinity, temperature, sea ice conditions, and fecal input by humans and local wildlife populations. This study assessed the influence of these factors on the distribution of presumptive fecal coliforms around Rothera Point, Adelaide Island, Antarctic Peninsula during the austral summer and winter of February 1999 to September 1999. Each factor had a different degree of influence depending on the time of year. In summer (February), although the station population was high, presumptive fecal coliform concentrations were low, probably due to the biologically damaging effects of solar radiation. However, summer algal blooms reduced penetration of solar radiation into the water column. By early winter (April), fecal coliform concentrations were high, due to increased fecal input by migrant wildlife, while solar radiation doses were low. By late winter (September), fecal coliform concentrations were high near the station sewage outfall, as sea ice formation limited solar radiation penetration into the sea and prevented wind-driven water circulation near the outfall. During this study, environmental factors masked the effect of station population numbers on sewage plume size. If sewage production increases throughout the Antarctic, environmental factors may become less significant and effective sewage waste management will become increasingly important. These findings highlight the need for year-round monitoring of fecal coliform distribution in Antarctic waters near research stations to produce realistic evaluations of sewage pollution persistence and dispersal.
Maheux, Andrée F; Dion-Dupont, Vanessa; Bouchard, Sébastien; Bisson, Marc-Antoine; Bergeron, Michel G; Rodriguez, Manuel J
2015-06-01
The MI agar, Colilert(®), Chromocult coliform(®) agar, and DC with BCIG agar chromogenic culture-based methods used to assess microbiological quality of drinking water were compared in terms of their ubiquity, sensitivity, ease of use, growth of atypical colonies and affordability. For ubiquity, 129 total coliform (representing 76 species) and 19 Escherichia coli strains were tested. Then, 635 1-L well water samples were divided into 100 mL subsamples for testing by all four methods. Test results showed that 70.5, 52.7, 36.4, and 23.3% of the non-E. coli total coliform strains and 94.7, 94.7, 89.5, and 89.5% of the 19 E. coli strains yielded a positive signal with the four methods, respectively. They also yielded a total coliform positive signal for 66.5, 51.7, 64.9, and 55.0% and an E. coli positive signal for 16.1, 14.8, 17.3, and 13.4% of the 635 well water samples tested, respectively. Results showed that Colilert(®) is the most expensive method tested in terms of reactants, yet it is the easiest to use. Large numbers of atypical colonies were also often observed on Chromocult coliform(®) and DC with BCIG, thereby challenging the target microorganism count. Thus, the MI agar method seems to be the best option for the assessment of drinking water quality.
Removal of total coliform and E. coli using zeliac as filter media
NASA Astrophysics Data System (ADS)
Ibrahim, Nurazim; Aziz, Hamidi Abdul; Yusoff, Mohd Suffian
2017-10-01
High loading of wastewater and surface run off into river contributed to large amount of microorganisms entering drinking water sources. The aim of this study was to investigate the capability of composite adsorbent namely Zeliac to remove total coliform and E. coli from river water using fixed bed column experiment. Two ranges of Zeliac particle sizes (1.18- 2 mm and 0.425- 0.6 mm) were applied to observe the effect of particle size on the removal of the selected pollutants. Kerian River water with a total coliform and E. coli concentration of 14, 082 ± 4, 209 and 208 ± 166 MPN/100 mL respectively was continuously supplied to the column at constant flow rate of 20 (Column A) and 21 ml/min (Column B) for 991 hours. The presence of total coliform and E. coli in the treated water were detected using Colilert test kit from IDEXX Corporation. The performance of Zeliac as filter media was analysed by a breakthrough curve plotted from normalized concentration (C/Co) against time. It was discovered that a difference in particle size does not give a significant impact to the removal of total coliform and E. coli in this system. According to the plotted breakthrough curves, Zeliac as filter media was capable to immobilize total coliform and E. coli for up to 31 hours of contact time. This finding shows that Zeliac has the potential to retain pathogenic microorganism such as E. coli in a continuous fluid flow.
Tracing the contamination origin of coliform bacteria in two small food-processing factories.
Tominaga, Tatsuya; Sekine, Masahiro; Oyaizu, Hiroshi
2008-09-01
The objective of this study was to trace contamination sources of coliform bacteria by comparing the types of coliforms between food samples and the processing environments in two small food-processing factories (factories A and B). Fermentation tests of five sugars enabled the successful classification of 16 representative type strains into eight distinct groups. The grouping procedure was then applied to comparison of the coliform flora between food products and various locations in their processing environments. The consistency between each food and the tested locations was evaluated using the Jaccard index. The air conditioner and refrigeration room floor in factory A showed an index of 1.00, while the shaping machine in factory B showed an index of 0.98, indicating that these locations could be contamination sources. The validity of our results was confirmed by randomly amplified polymorphic DNA, which showed 100% matched profiles between the air conditioner and the food in factory A, and highly matched profiles between the machine and the food in factory B. This method for comparing the coliform flora between food and environments has the potential to be a reliable tracing tool for various food industries.
Kassenga, Gabriel R
2007-03-01
The consumption of bottled and plastic-bagged drinking water in Tanzania has increased largely because of the deteriorating quality of tap water. It is uncertain whether these water products are safe for drinking. In this study, the microbiological quality of bottled and plastic-bagged drinking water sold in Dar es Salaam, Tanzania, was investigated. One hundred and thirty samples representing 13 brands of bottled water collected from shops, supermarkets and street vendors were analysed for total coliform and faecal coliform organisms as well as heterotrophic bacteria. These were compared with 61 samples of tap water. Heterotrophic bacteria were detected in 92% of the bottled water samples analysed. Total and faecal coliform bacteria were present in 4.6% and 3.6%, respectively, of samples analysed with a tendency for higher contamination rates in plastic-bagged drinking water. Microbiological quality of tap water was found to be worse compared with bottled water, with 49.2% and 26.2% of sampling points showing the presence of total coliform and faecal coliform organisms, respectively. The results suggest caution and vigilance to avert outbreaks of waterborne diseases from these types of drinking water.
Van Donsel, Dale J.; Geldreich, Edwin E.; Clarke, Norman A.
1967-01-01
Survival of a fecal coliform (Escherichia coli) and a fecal streptococcus (Streptococcus faecalis var. liquifaciens) was studied through several years at shaded and exposed outdoor soil plots. Death rates for both organisms were calculated for the different seasons at both sites. The 90% reduction times for the fecal coliform ranged from 3.3 days in summer to 13.4 days in autumn. For the fecal streptococcus, 90% reduction times were from 2.7 days in summer to 20.1 days in winter. During summer, the fecal coliform survived slightly longer than the fecal streptococcus; during autumn, survival was the same; and in spring and winter the fecal streptococcus survived much longer than the fecal coliform. Both organisms were isolated from storm-water runoff collected below a sampling site when counts were sufficiently high in soil. Isolation was more frequent during prolonged rains, lasting up to 10 days, than during short rain storms. There was evidence of aftergrowth of nonfecal coliforms in the soil as a result of temperature and rainfall variations. Such aftergrowth may contribute to variations in bacterial count of storm-water runoff which have no relation to the sanitary history of the drainage area. PMID:16349746
Invik, Jesse; Barkema, Herman W; Massolo, Alessandro; Neumann, Norman F; Checkley, Sylvia
2017-10-01
With increasing stress on our water resources and recent waterborne disease outbreaks, understanding the epidemiology of waterborne pathogens is crucial to build surveillance systems. The purpose of this study was to explore techniques for describing microbial water quality in rural drinking water wells, based on spatiotemporal analysis, time series analysis and relative risk mapping. Tests results for Escherichia coli and coliforms from private and small public well water samples, collected between 2004 and 2012 in Alberta, Canada, were used for the analysis. Overall, 14.6 and 1.5% of the wells were total coliform and E. coli-positive, respectively. Private well samples were more often total coliform or E. coli-positive compared with untreated public well samples. Using relative risk mapping we were able to identify areas of higher risk for bacterial contamination of groundwater in the province not previously identified. Incorporation of time series analysis demonstrated peak contamination occurring for E. coli in July and a later peak for total coliforms in September, suggesting a temporal dissociation between these indicators in terms of groundwater quality, and highlighting the potential need to increase monitoring during certain periods of the year.
FECAL COLIFORM INCREASE AFTER CENTRIFUGATION
The Water Environment Research Foundation (WERF) recently published a report titled Examination of Reactivation and Regrowth of Fecal Coliforms in Anaerobically Digested Sludges. Seven full-scale publicly owned treatment facilities were sampled several times to determine if bacte...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
.... The proposed revisions require systems that have an indication of coliform contamination in the... deaths due to potential fecal contamination and waterborne pathogen exposure. This proposal also...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Giardia lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal) zero coliforms and Escherichia coli (5) Cryptosporidium zero (6) Escherichia coli (E. coli) zero (b) The MCLG...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Giardia lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal) zero coliforms and Escherichia coli (5) Cryptosporidium zero (6) Escherichia coli (E. coli) zero (b) The MCLG...
NASA Astrophysics Data System (ADS)
Maghrebi, M.; Tajrishy, M.
2010-12-01
Jajrood River watershed is one of the main drinking water resources of the capital city of Tehran, Iran. In addition it has been available as many recreational usages especially in the warm months. As a result of being located near one of the crowded cities of the world, a variety of microbial pollutions is commonly perceived in the Jajrood River. Among them, there are strong concerns about fecal coliform bacteria concentration. This article aimed to model fate and transport of fecal coliform bacteria in Jajrood River watershed using Soil and Water Assessment Tool (SWAT) model version 2005. Potential pollutant sources in the study area were detected and quantified for modeling purposes. In spite of being lack of knowledge about bacteria die-off rate in small river bodies, as well as in other watershed-based forms, fecal coliform bacteria die-off rates were estimated using both laboratory and field data investigations with some simplifications. The SWAT model was calibrated over an extended time period (1997-2002) for this watershed. The river flow calibrated using SUFI-2 software and resulted in a very good outputs (R2=0.82, E=0.81). Furthermore SWAT model was validated over January 2003 to September 2005 in the study area and has resulted in good outputs (R2=0.61, E=0.57). This research illustrates SWAT 2005 capability to model fecal coliform bacteria in a populated watershed, and deals with most of watershed microbial pollution sources that are usually observed in developing countries. Fecal coliform concentration simulation results were mostly in the same order in comparison with real data. However, Differences were judged to be related to lack of input data. In this article different aspects of SWAT capabilities for modeling of fecal coliform bacteria concentration will be reviewed and it will present new insights in bacteria modeling procedures especially for mountainous, high populated and small sized watersheds.
Harmon, S Michele; West, Ryan T; Yates, James R
2014-12-01
Sources of fecal coliform pollution in a small South Carolina (USA) watershed were identified using inexpensive methods and commonly available equipment. Samples from the upper reaches of the watershed were analyzed with 3M(™) Petrifilm(™) count plates. We were able to narrow down the study's focus to one particular tributary, Sand River, that was the major contributor of the coliform pollution (both fecal and total) to a downstream reservoir that is heavily used for recreation purposes. Concentrations of total coliforms ranged from 2,400 to 120,333 cfu/100 mL, with sharp increases in coliform counts observed in samples taken after rain events. Positive correlations between turbidity and fecal coliform counts suggested a relationship between fecal pollution and stormwater runoff. Antibiotic resistance analysis (ARA) compared antibiotic resistance profiles of fecal coliform isolates from the stream to those of a watershed-specific fecal source library (equine, waterfowl, canines, and untreated sewage). Known fecal source isolates and unknown isolates from the stream were exposed to six antibiotics at three concentrations each. Discriminant analysis grouped known isolates with an overall average rate of correct classification (ARCC) of 84.3 %. A total of 401 isolates from the first stream location were classified as equine (45.9 %), sewage (39.4 %), waterfowl (6.2 %), and feline (8.5 %). A similar pattern was observed at the second sampling location, with 42.6 % equine, 45.2 % sewage, 2.8 % waterfowl, 0.6 % canine, and 8.8 % feline. While there were slight weather-dependent differences, the vast majority of the coliform pollution in this stream appeared to be from two sources, equine and sewage. This information will contribute to better land use decisions and further justify implementation of low-impact development practices within this urban watershed.
1980-01-01
In a multi-laboratory trial, minerals-modified glutamate medium (MMGM) was compared with lauryl tryptose lactose broth (LTLB) in the multiple tube method for the enumeration of coliform organisms, including Escherichia coli, in water. Samples of raw and chlorinated waters yielded a total of 2313 positive tube-reactions with MMGM and 2174 with LTLB. These were interpreted either as E. coli; other coliform organisms; or as false positive reactions. The results at first reading (18 or 24 h) and at 48 h have been analysed statistically in terms of (i) most probable numbers of coliform organisms; (ii) positive reactions and their interpretation; and (iii) whether or not the sample yielded any E. coli or other coliform organisms. All three analyses indicated the same trends. For the detection of E. coli in raw waters LTLB was better than MMGM at 18-24 h, but MMGM was better at 48 h with waters containing small numbers of coliform organisms; for raw waters with greater numbers of organisms, both media performed equally well. Analysis of a subset of samples read at both 18 and 24 h indicated that the superiority of LTLB over MMGM with raw waters disappeared by 24 h. For chlorinated waters, LTLB yielded more positive gas reactions at 18-24 h, but fewer of these were E. coli than with MMGM; at 48 h MMGM was clearly better than LTLB for total coliform organisms including E. coli--especially if the numbers were small. MMGM therefore remains the medium of choice for the detection of E. coli as an indicator of faecal contamination of chlorinated drinking water supplies. It is also better for the detection of small numbers of E. coli in other waters. PMID:6762395
FECAL COLIFORM INCREASE AFTER CENTRIFUGATION: EPA PERSPECTIVE
The Water Environment Research Foundation (WERF) recently published a report titled Examination of Reactivation and Regrowth of Fecal Coliforms in Anaerobically Digested Sludges. Seven full-scale publicly owned treatment facilities were sampled several times to determine if bacte...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal coliforms and Escherichia coli) zero. (5) Cryptosporidium zero. [54 FR 27527, 27566, June 29, 1989; 55 FR 25064, June 19...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2012 CFR
2012-07-01
... lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal coliforms and Escherichia coli) zero. (5) Cryptosporidium zero. [54 FR 27527, 27566, June 29, 1989; 55 FR 25064, June 19...
40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... lamblia zero (2) Viruses zero (3) Legionella zero (4) Total coliforms (including fecal coliforms and Escherichia coli) zero. (5) Cryptosporidium zero. [54 FR 27527, 27566, June 29, 1989; 55 FR 25064, June 19...
ANALYZING BIOSOLIDS FOR FECAL COLIFORM AND SALMONELLAE
Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Standard protocols designed to quantify these organisms in water or wastewater were identified and specified in these regulations. However, proto...
Incidence of bacterial enteropathogens in foods from Mexico.
Wood, L V; Ferguson, L E; Hogan, P; Thurman, D; Morgan, D R; DuPont, H L; Ericsson, C D
1983-01-01
We examined food consumption patterns of U.S. students temporarily living in Guadalajara, Mexico. Consumption of foods prepared in Mexican homes was associated with an increased risk of acquisition of diarrhea. Foods from commercial sources and private Mexican homes in Guadalajara were subsequently examined for contamination with coliforms, fecal coliforms, and bacterial enteropathogens. For comparison, selected restaurant foods were obtained in Houston, Tex. Food obtained from Mexican homes showed generally higher counts of coliforms and fecal coliforms than those obtained from commercial sources in Mexico and Houston. The foods in Mexico, both from homes and commercial sources, commonly contained Escherichia coli and occasionally enterotoxigenic E. coli. Foods in Houston were not contaminated with E. coli or enterotoxigenic E. coli. Salmonella (17 isolates), Shigella (4 isolates), and Aeromonas hydrophila (1 isolate) were found only in the foods obtained from Mexican homes. Enterotoxigenic non-E. coli Enterobacteriaceae was recovered with approximately equal frequency from all food sources. PMID:6354085
Zhuravlev, P V; Aleshnya, V V; Panasovets, O P; Morozova, A A; Artemova, T Z; Talaeva, Yu G; Zagaynova, A V
2013-01-01
Due to intensive anthropogenic pollution of water environment generally accepted indicators of epidemic security of water bodies--common bacteria (CB) and thermotolerant coliform bacteria (TCB) do not always permit to obtain an objective characterization of bacterial contamination of tap water. From the point of view of authors the integral index--glucose positive coliform bacteria most adequately reflect the sanitary-hygienic and epidemiological situation of water bodies. In monitoring for bacterial quality of tap water it is advisable to determine glucose positive coliform bacteria, that will provide the relevance of estimation of the epidemiological safety of water use. According to the method developed by the authors the calculation of the index of population risk of acute intestinal infections (AHI) occurrence in dependence on the quality of tap water in Azov and Tsimlyansk towns.
NASA Astrophysics Data System (ADS)
Suhartono, S.; Ismail, Y. S.; Yulvizar, C.; Nursanty, R.; Mahyuddin, M.; Jannah, M.
2018-03-01
Of aquatic environment, antibiotic resistant bacteria, including total coliforms and E. coli disseminate and emerge at an alarming rate. The study aims to determine enumerate, isolate,E. coliand determine their antibiotic resistance and compare between those which were recovered from residentials and home industries in Banda Aceh and its surrounding area. The bacterial density and antibiotic susceptibility of total coliforms and E. coli were determined using Standard Total Coliform Multiple-Tube (MPN) Fermentation method and the disk diffusion method, respectively. Despite there was no significant difference of total coliforms and E. coli population between residentials and home industries (P > 0.05) in this study, their density as well as prevalence remained high in the water sample. This might expose serious health risks since the resistance might be easily spread acquired through horizontal gene transfer within the aquatic environment.
Human enteroviruses in oysters and their overlying waters.
Goyal, S M; Gerba, C P; Melnick, J L
1979-01-01
The presence of enteroviruses in oysters and oyster-harvesting waters of the Texas Gulf coast was monitored over a period of 10 months. Viruses were detected in water and oyster samples obtained from areas both open and closed to shellfish harvesting. Viruses were detected periodically in waters that met current bacteriological standards for shellfish harvesting. No significant statistical relationship was demonstrated between virus concentration in oysters and the bacteriological and physiochemical quality of water and shellfish. Viruses in water were, however, moderately correlated with total coliforms in water and oysters and with fecal coliforms in oysters. Total coliforms in water were realted to total coliforms in sediment were related only to total coliforms in sediment. Among the physiochemical characteristics of water, turbidity was related statistically to the organic matter content of water and to fecal coliforms in water. There was a marked effect of rainfall on the bacteriological quality of water. Of a total of 44 water samples, 26 yielded virus in concentrations from 4 to 167 plaque-forming units per 100-gallon (ca. 378.5-liter) sample. Of a total of 40 pools of 10 to 12 oysters each, virus was found in 14 pools at a concentration of 6 to 224 plaque-forming units per 100 g of oyster meat. On five occasions, virus was found in water samples when no virus could be detected in oysters harvested from the same sites. This study indicates that current bacteriological standards for determining the safety of shellfish and shellfish-growing waters do no reflect the occurrence of enteroviruses. PMID:222210
Bacteriology of Dehydrated Space Foods 1
Powers, Edmund M.; Ay, Carl; El-Bisi, Hamed M.; Rowley, Durwood B.
1971-01-01
The initial bacteriological requirement established in 1964 for space foods by the U.S. Army Natick Laboratories are: a total aerobic plate count (≤ 10,000 per g), a total coliform count (≤ 10 per g), fecal coliforms (negative per gram), fecal streptococci (≤ 20 per g), coagulase-positive staphylococci (negative in 5 g) and salmonellae (negative in 10 g). Of the space foods and prototypes tested during 1968 and 1969, 93% complied with the total aerobic plate count, 98% had less than 1 coliform per g, and 99% were negative for fecal coliforms; 88% complied with the streptococci requirement; 100 and 98% were negative for staphylococci and salmonellae, respectively. Nineteen food samples which did not comply (as indicated parenthetically by actual counts per gram) with the requirements were (i) total aerobic plate count: beef soup and gravy base (18,000), chicken soup and gravy base (57,000), spaghetti with meat sauce (12,100 and 14,000), sugared coffee (> 300,000), chocolate ice cream cubes (20,000), and each of four samples of chocolate candy (12,000 to 61,000); (ii) coliforms: two out of three vanilla milk drinks (16 and 127) and one beef hash bar (14); (iii) fecal coliforms: one sample of chicken soup and gravy base positive; (iv) fecal streptococci: two samples of peanut cubes (40 and 108), coconut cubes (75), chicken soup and gravy base (2,650), beef soup and gravy base (33), and five out of six flavored milk drinks (23 to 300); (v) salmonellae: one each of chicken and beef soup and gravy base were positive. Images PMID:4940878
Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa.
Mellor, Jonathan E; Smith, James A; Samie, Amidou; Dillingham, Rebecca A
2013-09-01
Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household ( n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm 2 ; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μ max , of 0.072 ± 0.003 h -1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth.
The microbiological quality of drinking water sold on the streets in Kumasi, Ghana.
Obiri-Danso, K; Okore-Hanson, A; Jones, K
2003-01-01
The aim of this study was to assess the microbiological quality of Ghanaian bottled and plastic-bagged drinking water sold on the streets of Metropolitan Kumasi, Ghana. Eight bottled, 88 factory-filled plastic sachet and 40 hand-filled hand-tied polythene-bagged drinking waters were examined for the presence of heterotrophic bacteria total viable counts (TVCs), indicators of faecal contamination (total coliforms, faecal coliforms and enterococci) and for lead, manganese and iron. Heterotrophic bacteria were found in all three types of water with TVCs per millilitre ranging from 1 to 460 for bottled water, 2-6.33 x 10(5) for factory-bagged sachet water and 2.33 x 10(3)-7.33 x 10(12) for hand-filled hand-tied bagged water. None of the microbial indicators of faecal contamination were detected in bottled water, whereas 4.5% of the factory-bagged sachets contained total coliforms and 2.3% faecal coliforms, and 42.5% of the hand-filled hand-tied bags contained total coliforms, 22.5% faecal coliforms and 5% enterococci. Iron was found in all three types of drinking water but at concentrations well within the WHO recommendations. Lead and manganese were not detected. Ghanaian bottled water is of good microbiological quality but some factory-bagged sachet and hand-filled hand-tied polythene-bagged drinking water are of doubtful quality. Factory-bagged sachets and hand-filled hand-tied bags of drinking water sold in Ghana should be monitored for microbiological contamination, with the aim of raising standards in the industry and re-assuring the public.
Human enteroviruses in oysters and their overlying waters.
Goyal, S M; Gerba, C P; Melnick, J L
1979-03-01
The presence of enteroviruses in oysters and oyster-harvesting waters of the Texas Gulf coast was monitored over a period of 10 months. Viruses were detected in water and oyster samples obtained from areas both open and closed to shellfish harvesting. Viruses were detected periodically in waters that met current bacteriological standards for shellfish harvesting. No significant statistical relationship was demonstrated between virus concentration in oysters and the bacteriological and physiochemical quality of water and shellfish. Viruses in water were, however, moderately correlated with total coliforms in water and oysters and with fecal coliforms in oysters. Total coliforms in water were realted to total coliforms in sediment were related only to total coliforms in sediment. Among the physiochemical characteristics of water, turbidity was related statistically to the organic matter content of water and to fecal coliforms in water. There was a marked effect of rainfall on the bacteriological quality of water. Of a total of 44 water samples, 26 yielded virus in concentrations from 4 to 167 plaque-forming units per 100-gallon (ca. 378.5-liter) sample. Of a total of 40 pools of 10 to 12 oysters each, virus was found in 14 pools at a concentration of 6 to 224 plaque-forming units per 100 g of oyster meat. On five occasions, virus was found in water samples when no virus could be detected in oysters harvested from the same sites. This study indicates that current bacteriological standards for determining the safety of shellfish and shellfish-growing waters do no reflect the occurrence of enteroviruses.
Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa
Mellor, Jonathan E.; Samie, Amidou; Dillingham, Rebecca A.
2014-01-01
Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household (n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm2; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μmax, of 0.072 ± 0.003 h−1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth. PMID:25190902
Kumar, A Yudhistra; Reddy, M Vikram
2008-01-01
Most Probable Number (MPN) of Total Coliforms (TC) and Faecal Coliforms (FC), and the physicochemical variables - temperature, Dissolved Oxygen (D.O.), Biochemical Oxygen Demand (B.O.D.), Chemical Oxygen Demand (C.O.D.), nitrates, phosphates and chlorides of municipal raw sewage and that of aeration tank and secondary clarifier of the Sewage Treatment Plant (STP), in relation to water at the treated sewage out-fall point, down-stream and up-stream of the Buckingham Canal at Kalpakkam were analyzed. Total Coliform and Faecal Coliform MPN counts were higher, 170 and 70/100 mL respectively in the raw sewage. However, the counts of the former in the aeration tank though remained similar, that of FC decreased to 50/100 mL; both of the counts further decreased to 30 and 44/100 mL respectively, in the secondary clarifier and were 110 and 23/100 mL, respectively at the treated sewage out-fall point in the canal. Total coliforms MPN was more than 18 times less in the water at the up-stream than that of the treated sewage out-fall point in the canal. Interestingly MPN of the FC in the up-stream water was nil while it was 8/100 mL in the canal's down-stream point. It is concluded that the FC, B.O.D., C.O.D., nitrates, phosphates and chlorides decreased and the D.O. increased in the treated-sewage due to the treatment of raw sewage through the STP.
Entry, J A; Farmer, N
2001-01-01
Large-scale deposition of animal manure can result in contamination of surface and ground water and in potential transfer of disease-causing enteric bacteria to animals or humans. We measured total coliform bacteria (TC), fecal coliform bacteria (FC), NO3, NH4, total P, and PO4 in ground water flowing from basalt and sand aquifers, in wells into basalt and sand aquifers, in irrigation water, and in river water. Samples were collected monthly for 1 yr. Total coliform and FC numbers were always higher in irrigation water than in ground water, indicating that soil and sediment filtered most of these bacteria before they entered the aquifers. Total coliform and FC numbers in ground water were generally higher in the faster flowing basalt aquifer than in the sand aquifer, indicating that the slower flow and finer grain size may filter more TC and FC bacteria from water. At least one coliform bacterium/100 mL of water was found in ground water from both basalt and sand aquifers, indicating that ground water pumped from these aquifers is not necessarily safe for human consumption according to the American Public Health Association and the USEPA. The NO3 concentrations were usually higher in water flowing from the sand aquifer than in water flowing from the basalt aquifer or in perched water tables in the basalt aquifer. The PO4 concentrations were usually higher in water flowing from the basalt aquifer than in water flowing from the sand aquifer. The main concern is fecal contamination of these aquifers and health consequences that may arise from human consumption.
Holding effects on coliform enumeration in drinking water samples.
McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C
1985-01-01
Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... laboratory analysis as required by the EC of the finished product including: Total aerobic bacteria, coliforms (30 [deg]C), coliforms (44.5 [deg]C), anaerobic sulphite-reducing bacteria (no gas production...
Public Notification Instructions and Templates for the Revised Total Coliform Rule (RTCR)
EPA has developed public notification (PN) templates to help with implementation of the PN Rule. This document aims to assist water systems with the Public Notification requirements specific to the Revised Total Coliform Rule (RTCR).
33 CFR 159.309 - Limitations on discharge of treated sewage or graywater.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30-day period does not exceed 20 fecal coliform/100 milliliters (ml) and not more than 10 percent of the samples exceed 40 fecal coliform/100 ml; (4) Concentrations of total residual chlorine do not...
33 CFR 159.309 - Limitations on discharge of treated sewage or graywater.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30-day period does not exceed 20 fecal coliform/100 milliliters (ml) and not more than 10 percent of the samples exceed 40 fecal coliform/100 ml; (4) Concentrations of total residual chlorine do not...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...
Revised Total Coliform Rule Implementation in Wyoming and on Tribal Lands in EPA Region 8
The Revised Total Coliform Rule (RTCR) aims to increase public health protection through the reduction of potential pathways for fecal contamination in the distribution system of a public water system (PWS).
40 CFR 432.25 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fecal coliform, O&G, and TSS are the same as the limitations specified in § 432.22(a)(1), and the... on-site, the standards for BOD5, fecal coliform, O&G, and TSS are the same as the corresponding...
40 CFR 432.85 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
..., fecal coliform, O&G, and TSS specified in § 432.82(a). (b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS...
40 CFR 432.35 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
..., fecal coliform, TSS, and O&G are the same as the limitations specified in § 432.32(a)(1) and the... on-site, the standards for BOD5, fecal coliform, TSS, and O&G are the same as the corresponding...
40 CFR 432.65 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
..., fecal coliform, O&G, and TSS specified in § 432.62(a). (b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS...
40 CFR 432.35 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fecal coliform, TSS, and O&G are the same as the limitations specified in § 432.32(a)(1) and the... on-site, the standards for BOD5, fecal coliform, TSS, and O&G are the same as the corresponding...
40 CFR 432.45 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fecal coliform, TSS, and O&G are the same as the limitations specified in § 432.42(a)(1); and standards... on-site, the standards for BOD5, fecal coliform, TSS, and O&G are the same as the limitations...
40 CFR 432.15 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
..., fecal coliform, O&G, and TSS are the same as the corresponding limitations specified in § 432.12(a)(1... on-site, the standards for BOD5, fecal coliform, O&G, and TSS are the same as the limitations...
40 CFR 432.25 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
..., fecal coliform, O&G, and TSS are the same as the limitations specified in § 432.22(a)(1), and the... on-site, the standards for BOD5, fecal coliform, O&G, and TSS are the same as the corresponding...
40 CFR 432.85 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fecal coliform, O&G, and TSS specified in § 432.82(a). (b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS...
40 CFR 432.15 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
..., fecal coliform, O&G, and TSS are the same as the corresponding limitations specified in § 432.12(a)(1... on-site, the standards for BOD5, fecal coliform, O&G, and TSS are the same as the limitations...
40 CFR 432.45 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
..., fecal coliform, TSS, and O&G are the same as the limitations specified in § 432.42(a)(1); and standards... on-site, the standards for BOD5, fecal coliform, TSS, and O&G are the same as the limitations...
A Revised Total Coliform Rule Guide for Small Public Water Systems
This document aims to assist small water systems serving 1,000 persons with fewer in complying with the requirements of the Revised Total Coliform Rule (RTCR). It is divided into four parts, Parts A, B, C and D.
40 CFR 141.405 - Reporting and recordkeeping for ground water systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total coliform-positive samples that are not invalidated under § 141.21(c) until March 31...
Standridge, J H; Delfino, J J; Kleppe, L B; Butler, R
1979-01-01
A public swimming beach in Madison, wis., experienced intermittent high fecal coliform counts during the late summer and early fall of 1978. Public health officials closed the beach on a number of occasions. A public health survey identified a combination of waterfowl wastes and meteorological events as the explanation for the high bacteria counts. Fecal coliform bacteria were deposited by mallard ducks and multiplied in the beach sands. The bacteria were subsequently transported into the lake and resulted in high fecal coliform counts in the swimming area. PMID:394683
Fecal coliforms on environmental surfaces in two day care centers.
Weniger, B G; Ruttenber, A J; Goodman, R A; Juranek, D D; Wahlquist, S P; Smith, J D
1983-01-01
A survey of environmental surfaces in two Atlanta area day care centers was conducted to determine the prevalence of fecal coliform bacteria, considered a marker for the presence of fecal contamination which might contain pathogenic parasites, bacteria, or viruses. Fecal coliforms were found in 17 (4.3%) of 398 representative samples of building surfaces, furniture, and other objects. These surfaces may be involved in the chain of transmission of enteric diseases among children. Therefore, disinfection of inanimate objects, in addition to good handwashing, may be important in controlling the spread of enteric diseases in day care centers. PMID:6830225
Tobin, R S; Dutka, B J
1977-01-01
A comparative study was made of nine commonly used membrane filters from five manufacturers, all recommended for enumeration of coliform bacteria. Bacterial recoveries and flow rates were examined from three types of water and were found to correlate with the surface pore structure determined by scanning electron microscopy. The sorption of metals was also determined. The results of these studies indicate that the five best membranes for fecal coliform recovery could be placed in two groups: Millipore HC and Gelman, followed by Johns-Manville SG and AG and Sartorius 13806. Images PMID:329763
Thermotolerant coliforms are not a good surrogate for Campylobacter spp. in environmental water.
St-Pierre, Karen; Lévesque, Simon; Frost, Eric; Carrier, Nathalie; Arbeit, Robert D; Michaud, Sophie
2009-11-01
This study aimed to assess the importance of quantitatively detecting Campylobacter spp. in environmental surface water. The prevalence and the quantity of Campylobacter spp., thermotolerant coliforms, and Escherichia coli in 2,471 samples collected weekly, over a 2-year period, from 13 rivers and 12 streams in the Eastern Townships, Québec, Canada, were determined. Overall, 1,071 (43%), 1,481 (60%), and 1,463 (59%) samples were positive for Campylobacter spp., thermotolerant coliforms, and E. coli, respectively. There were weak correlations between the weekly distributions of Campylobacter spp. and thermotolerant coliforms (Spearman's rho coefficient = 0.27; P = 0.008) and between the quantitative levels of the two classes of organisms (Kendall tau-b correlation coefficient = 0.233; P < 0.0001). Well water samples from the Eastern Townships were also tested. Five (10%) of 53 samples from private surface wells were positive for Campylobacter jejuni, of which only 2 were positive for thermotolerant coliforms. These findings suggest that microbial monitoring of raw water by using only fecal indicator organisms is not sufficient for assessing the occurrence or the load of thermophilic Campylobacter spp. Insights into the role of environmental water as sources for sporadic Campylobacter infection will require genus-specific monitoring techniques.
Coliform Bacteria for Bioremediation of Waste Hydrocarbons
2017-01-01
Raw, domestic sewage of Kuwait City contained about 106 ml−1 colony forming units of Enterobacter hormaechei subsp. oharae (56.6%), Klebsiella spp. (36%), and Escherichia coli (7.4%), as characterized by their 16S rRNA-gene sequences. The isolated coliforms grew successfully on a mineral medium with crude oil vapor as a sole source of carbon and energy. Those strains also grew, albeit to different degrees, on individual n-alkanes with carbon chains between C9 and C36 and on the individual aromatic hydrocarbons, toluene, naphthalene, phenanthrene, and biphenyl as sole sources of carbon and energy. These results imply that coliforms, like other hydrocarbonoclastic microorganisms, oxidize hydrocarbons to the corresponding alcohols and then to aldehydes and fatty acids which are biodegraded by β-oxidation to acetyl CoA. The latter is a well-known key intermediate in cell material and energy production. E. coli cells grown in the presence of n-hexadecane (but not in its absence) exhibited typical intracellular hydrocarbon inclusions, as revealed by transmission electron microscopy. Raw sewage samples amended with crude oil, n-hexadecane, or phenanthrene lost these hydrocarbons gradually with time. Meanwhile, the numbers of total and individual coliforms, particularly Enterobacter, increased. It was concluded that coliform bacteria in domestic sewage, probably in other environmental materials too, are effective hydrocarbon-biodegrading microorganisms. PMID:29082238
NASA Astrophysics Data System (ADS)
Hatha, A. A. Mohamed; Neethu, C. S.; Nikhil, S. M.; Rahiman, K. M. Mujeeb; Krishnan, K. P.; Saramma, A. V.
2015-12-01
The objective of this study was to determine the prevalence of antibiotic resistance among aerobic heterotrophic bacteria and coliform bacteria from water and sediment of Kongsfjord. The study was based on the assumption that arctic fjord environments are relatively pristine and offer very little selection pressure for drug resistant mutants. In order to test the hypothesis, 200 isolates belonging to aerobic heterotrophic bacteria and 114 isolates belonging to coliforms were tested against 15 antibiotics belonging to 5 different classes such as beta lactams, aminoglycosides, quinolones, sulpha drugs and tetracyclines. Resistance to beta lactam and extended spectrum beta lactam (ESBL) antibiotics was considerably high and they found to vary significantly (p < 0.05) between heterotrophic and coliform bacteria. Though the coliforms showed significantly high level of antibiotic resistance against ESBL's extent and diversity of antibiotic resistance (as revealed by multiple antibiotic resistance index and resistance patterns), was high in the aerobic heterotrophic bacteria. Most striking observation was that isolates from fjord sediments (both heterotrophic bacteria and coliforms) in general showed relatively high prevalence of antibiotic resistance against most of the antibiotics tested, indicating to better selection pressure for drug resistance mutants in the fjord sediments.
Rizzo, Luigi
2009-06-15
In this study the potential application of TiO(2) photocatalysis as primary disinfection system of drinking water was investigated in terms of coliform bacteria inactivation and injury. As model water the effluent of biological denitrification unit for nitrate removal from groundwater, which is characterized by high organic matter and bacteria release, was used. The injury of photocatalysis on coliform bacteria was characterized by means of selective (mEndo) and less selective (mT7) culture media. Different catalyst loadings as well as photolysis and adsorption effects were investigated. Photocatalysis was effective in coliform bacteria inactivation (91-99% after 60 min irradiation time, depending on both catalyst loading and initial density of coliform bacteria detected by mEndo), although no total removal was observed after 60 min irradiation time. The contribution of adsorption mechanism was significant (60-98% after 60 min, depending on catalyst loading) compared to previous investigations probably due to the nature of source water rich in particulate organic matter and biofilm. Photocatalysis process did not result in any irreversible injury (98.8% being the higher injury) under investigated conditions, thus a bacteria regrowth may take place under optimum environment conditions if any final disinfection process (e.g., chlorine or chlorine dioxide) is not used.
Rakhmanin, Yu A; Ivanova, L V; Artemova, T Z; Gipp, E K; Zagaynova, A V; Maksimkina, T N; Krasnyak, A V; Zhuravlev, P V; Aleshnya, V V; Panasovets, O P
2016-01-01
The used methodology of the scientific substantiation of indicators is in the establishment of the conformity of laws of vital activity of indicator and pathogenic microorganisms in the real conditions of the action of the complex of factors, including disinfecting agents. In the one water sample simultaneously there were determined both the general indicator (GICB), thermotolerant (TTCB), glucose positive (GPCB) coliform bacteria, E.coli. On the base of long-term research in the various regions of the Russian Federation, as well with bearing in mind the analysis of domestic and foreign data, comparing the water quality and the incidence of intestinal infections in population it is recommended to use the index of determination of the total number glucose positive coliform bacteria (GPCB), which brings together a much broader range of bacteria of the Enterobacteriaceae family in comparison with total coliform bacteria (TCB) and thermotolerant coliform bacteria (TTCB) and warrants the absence in the test volume of water as an indicator lactose positive (E.coli, TCB, TTCB) and pathogens (salmonella) and potentially pathogenic bacteria which do not ferment lactose. Proposed index of GPCB is shown to allow to assess epidemiological risks not only more accurate, but also more efficiently without increasing the cost performance of bacteriological research.
Græsbøll, Kaare; Damborg, Peter; Mellerup, Anders; Herrero-Fresno, Ana; Larsen, Inge; Holm, Anders; Nielsen, Jens Peter; Christiansen, Lasse Engbo; Angen, Øystein; Ahmed, Shahana
2017-01-01
ABSTRACT This study describes the results of a randomized clinical trial investigating the effect of oxytetracycline treatment dose and mode of administration on the selection of antibiotic-resistant coliform bacteria in fecal samples from nursery pigs. Nursery pigs (pigs of 4 to 7 weeks of age) in five pig herds were treated with oxytetracycline for Lawsonia intracellularis-induced diarrhea. Each group was randomly allocated to one of five treatment groups: oral flock treatment with a (i) high (20 mg/kg of body weight), (ii) medium (10 mg/kg), or (iii) low (5 mg/kg) dose, (iv) oral pen-wise (small-group) treatment (10 mg/kg), and (v) individual intramuscular injection treatment (10 mg/kg). All groups were treated once a day for 5 days. In all groups, treatment caused a rise in the numbers and proportions of tetracycline-resistant coliform bacteria right after treatment, followed by a significant drop by the time that the pigs left the nursery unit. The counts and proportions of tetracycline-resistant coliforms did not vary significantly between treatment groups, except immediately after treatment, when the highest treatment dose resulted in the highest number of resistant coliforms. A control group treated with tiamulin did not show significant changes in the numbers or proportions of tetracycline-resistant coliforms. Selection for tetracycline-resistant coliforms was significantly correlated to selection for ampicillin- and sulfonamide-resistant strains but not to selection for cefotaxime-resistant strains. In conclusion, the difference in the dose of oxytetracycline and the way in which the drug was applied did not cause significantly different levels of selection of tetracycline-resistant coliform bacteria under the conditions tested. IMPORTANCE Antimicrobial resistance is a global threat to human health. Treatment of livestock with antimicrobials has a direct impact on this problem, and there is a need to improve the ways that we use antimicrobials in livestock production. We hypothesized that antibiotic resistance development following treatment of diarrhea in nursery pigs could be reduced either by lowering the dose of oxytetracycline or by replacing the commonly used practice of flock treatment with individual or small-group treatments, since this would reduce the number of pigs treated. However, the study showed no significant difference between treatment groups with respect to the number or proportion of tetracycline-resistant coliforms selected. The most important conclusion is that under practical field conditions, there will be no added value, in terms of lowering resistance development, by exchanging flock treatment for individual or small-group treatment of nursery pigs. The reason for the lack of an effect of single-animal treatment is probably that such animals share the environment with treated animals and take up resistant bacteria from the environment. PMID:28389548
Græsbøll, Kaare; Damborg, Peter; Mellerup, Anders; Herrero-Fresno, Ana; Larsen, Inge; Holm, Anders; Nielsen, Jens Peter; Christiansen, Lasse Engbo; Angen, Øystein; Ahmed, Shahana; Folkesson, Anders; Olsen, John Elmerdahl
2017-06-15
This study describes the results of a randomized clinical trial investigating the effect of oxytetracycline treatment dose and mode of administration on the selection of antibiotic-resistant coliform bacteria in fecal samples from nursery pigs. Nursery pigs (pigs of 4 to 7 weeks of age) in five pig herds were treated with oxytetracycline for Lawsonia intracellularis -induced diarrhea. Each group was randomly allocated to one of five treatment groups: oral flock treatment with a (i) high (20 mg/kg of body weight), (ii) medium (10 mg/kg), or (iii) low (5 mg/kg) dose, (iv) oral pen-wise (small-group) treatment (10 mg/kg), and (v) individual intramuscular injection treatment (10 mg/kg). All groups were treated once a day for 5 days. In all groups, treatment caused a rise in the numbers and proportions of tetracycline-resistant coliform bacteria right after treatment, followed by a significant drop by the time that the pigs left the nursery unit. The counts and proportions of tetracycline-resistant coliforms did not vary significantly between treatment groups, except immediately after treatment, when the highest treatment dose resulted in the highest number of resistant coliforms. A control group treated with tiamulin did not show significant changes in the numbers or proportions of tetracycline-resistant coliforms. Selection for tetracycline-resistant coliforms was significantly correlated to selection for ampicillin- and sulfonamide-resistant strains but not to selection for cefotaxime-resistant strains. In conclusion, the difference in the dose of oxytetracycline and the way in which the drug was applied did not cause significantly different levels of selection of tetracycline-resistant coliform bacteria under the conditions tested. IMPORTANCE Antimicrobial resistance is a global threat to human health. Treatment of livestock with antimicrobials has a direct impact on this problem, and there is a need to improve the ways that we use antimicrobials in livestock production. We hypothesized that antibiotic resistance development following treatment of diarrhea in nursery pigs could be reduced either by lowering the dose of oxytetracycline or by replacing the commonly used practice of flock treatment with individual or small-group treatments, since this would reduce the number of pigs treated. However, the study showed no significant difference between treatment groups with respect to the number or proportion of tetracycline-resistant coliforms selected. The most important conclusion is that under practical field conditions, there will be no added value, in terms of lowering resistance development, by exchanging flock treatment for individual or small-group treatment of nursery pigs. The reason for the lack of an effect of single-animal treatment is probably that such animals share the environment with treated animals and take up resistant bacteria from the environment. Copyright © 2017 American Society for Microbiology.
Escherichia coli and fecal-coliform bacteria as indicators of recreational water quality
Francy, D.S.; Myers, Donna N.; Metzker, K.D.
1993-01-01
In 1986, the U.S. Environmental Protection Agency (USEPA) recommended that Escherichia coli (E. coli) be used in place of fecal-coliform bacteria in State recreational water-quality standards as an indicator of fecal contamination. This announcement followed an epidemiological study in which E. coli concentration was shown to be a better predictor of swimming-associated gastrointestinal illness than fecal-coliform concentration. Water-resource managers from Ohio have decided to collect information specific to their waters and decide whether to use E. coli or fecal-coliform bacteria as the basis for State recreational water-quality standards. If one indicator is a better predictor of recreational water quality than the other and if the relation between the two indicators is variable, then the indicator providing the most accurate measure of recreational water quality should be used in water-quality standards. Water-quality studies of the variability of concentrations of E. coli to fecal-coliform bacteria have shown that (1) concentrations of the two indicators are positively correlated, (2) E. coli to fecal-coliform ratios differ considerably from site to site, and (3) the E. coli criteria recommended by USEPA may be more difficult to meet than current (1992) fecal-coliform standards. In this study, a statistical analysis was done on concentrations of E. coli and fecal-coliform bacteria in water samples collected by two government agencies in Ohio-- the U.S. Geological Survey (USGS) and the Ohio River Valley Water Sanitation Commission (ORSANCO). Data were organized initially into five data sets for statistical analysis: (1) Cuyahoga River, (2) Olentangy River, (3) Scioto River, (4) Ohio River at Anderson Ferry, and (5) Ohio River at Cincinnati Water Works and Tanners Creek. The USGS collected the data in sets 1, 2, and 3, whereas ORSANCO collected the data in sets 4 and 5. The relation of E. coli to fecal-coliform concentration was investigated by use of linear-regression analysis and analysis of covariance. Log-transformed E. coli and fecal-coliform concentrations were highly correlated in all data sets (r-values ranged from 0.929 to 0.984). Linear regression analysis on USGS and ORSANCO data sets showed that concentration of E. coli could be predicted from fecal-coliform concentration (coefficients of determination (R2) ranged from 0.863 to 0.970). Results of analysis of covariance (ANCOVA) indicated that the predictive equations among the three USGS data sets and two ORSANCO data sets were not significantly different and that the data could be pooled into two large data sets, one for USGS data and one for ORSANCO data. However, results of ANCOVA indicated that USGS and ORSANCO data could not be pooled into one large data set. Predictions of E. coli concentrations calculated for USGS And ORSANCO regression relations, based on fecal-coliform concentrations set to equal Ohio water-quality standards, further showed the differences in E. coli to fecal-coliform relations among data sets. For USGS data, a predicted geometric mean of 176 col/100 mL (number of colonies per 100 milliliters) was greater than the current geometric-mean E. coli standard for bathing water of 126 col/100mL. In contrast, for ORSANCO data, the predicted geometric mean of 101 col/100 mL was less than the current E. coli standard. The risk of illness associated with predicted E. coli concentrations for USGS and ORSANCO data was evaluated by use of the USEPA regression equation that predicts swimming-related gastroenteritis rates from E. coli concentrations.1 The predicted geometric-mean E. coli concentrations for bathing water of 176 col/100 mL for USGS data and 101 col/100 mL for ORSANCO data would allow 9.4 and 7.1 gastrointestinal illnesses per 1,000 swimmers, respectively. This prediction compares well with the illness rate of 8 individuals per 1,000 swimmers estimated by the USEPA for an E. coli concentration of 126 col/100 mL. Therefore, the
HOLDING TIME STUDY FOR FECALS/SALMONELLA & CONNECTING LANGUAGE FOR 503 REGULATIONS
Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella have been developed and are currently in use for quantification of these organisms. Recently c...
This memorandum provides guidance to primacy agencies with enforcement responsibility under the Safe Drinking Water Act (SDWA) concerning the requirements to transition public water systems (PWSs) from the Total Coliform Rule (TCR) to the RTCR
APPARENT BIAS IN RIVER WATER INOCULUM FOLLOWING CENTRIFUGATION
We collected four measures of viable bacterial concentration (heterotrophic plate count, total coliform, fecal coliform, and Escherichia coli) and three measures of well color development in Biolog GN2 microtiter plates from water samples that were collected on two or three separ...
40 CFR 432.75 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... achieve the standards for BOD5, fecal coliform, O&G, and TSS specified in § 432.72(a). (b) Facilities that..., fecal coliform, O&G, and TSS specified in § 432.72(b) and the limitations for ammonia (as N) and total...
40 CFR 432.95 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... standards for BOD 5, fecal coliform, O&G, and TSS specified in § 432.92(a). (b) Facilities that generate... coliform, O&G, and TSS specified in § 432.92(b) and the limitations for ammonia (as N) and total nitrogen...
Compliance Monitoring of Drinking Water Supplies
ERIC Educational Resources Information Center
Haukebo, Thomas; Bernius, Jean
1977-01-01
The most frequent testing required under the Safe Drinking Water Act of 1974 is for turbidity and coliform. Free chlorine residual testing can be substituted for part of the coliform requirement. Described are chemical procedures for performing this test. References are given. (Author/MA)
Ekwanzala, Mutshiene Deogratias; Abia, Akebe Luther King; Ubomba-Jaswa, Eunice; Keshri, Jitendra; Momba, Ndombo Benteke Maggy
2017-12-01
To date, the microbiological quality of river sediments and its impact on water resources are not included in the water quality monitoring assessment. Therefore, the aim of this study was to establish genetic relatedness between faecal coliforms and enterococci isolated from the river water and riverbed sediments of Apies River to better understand the genetic similarity of microorganisms between the sediment and water phases. Indicator bacteria were subjected to a molecular study, which consisted of PCR amplification and sequence analysis of the 16S rRNA and 23S rRNA gene using specific primers for faecal coliforms and enterococci, respectively. Results revealed that the Apies River had high faecal pollution levels with enterococci showing low to moderate correlation coefficient (r 2 values ranged from 0.2605 to 0.7499) compared to the faecal coliforms which showed zero to low correlation (r 2 values ranged from 0.0027 to 0.1407) indicating that enterococci may be better indicator than faecal coliforms for detecting faecal contamination in riverbed sediments. The phylogenetic tree of faecal coliforms revealed a 98% homology among their nucleotide sequences confirming the close genetic relatedness between river water and riverbed sediment isolates. The phylogenetic tree of the enterococci showed that Enterococcus faecalis and Enterococcus faecium are the predominant species found in both river water and riverbed sediments with bootstrap values of ≥99%. A high degree of genetic relatedness between sediment and water isolates indicated a possible common ancestry and transmission pathway. We recommend the microbial monitoring of riverbed sediments as it harbours more diverse microbial community and once resuspended may cause health and environmental problems.
Influence of storage and preservation on microbiological quality of silo ovine milk.
de Garnica, M L; Santos, J A; Gonzalo, C
2011-04-01
This study was designed to analyze the effects of the storage and preservation conditions on counts of mesophilic, thermoduric, psychotrophic, coliform, Escherichia coli, Streptococcus agalactiae, and Staphylococcus aureus organisms in silo ovine milk. A total of 910 analytical determinations were conducted from aliquots of 10 silo ovine milks. The conditions tested were unpreserved and azidiol-preserved milk stored at 4°C, and unpreserved milk stored at -20°C. Milk aged 2, 24, 48, 72, and 96 h post-collection for refrigerated aliquots, and 7, 15, and 30 d post-collection for frozen aliquots. The factors silo and storage conditions significantly contributed to variation of all microbiological variables, although milk age effect within storage was only significant for mesophilic, psychrotrophic, and coliform bacteria counts. In refrigerated raw milk, mesophile, psychrotroph, and coliform counts significantly increased over 96 h post-collection, whereas the other groups and bacteria species tested maintained their initial concentration. In all cases, azidiol preservation maintained the initial bacterial concentration in raw sheep milk under refrigeration throughout 96 h. Thus, azidiol was a suitable preservative for microbiological studies in sheep milk. Smallest counts were registered for frozen samples, particularly for coliforms, E. coli, Strep. agalactiae and Staph. aureus. Estimates of mesophilic, thermoduric and psychrotrophic organisms showed similar values on both azidiol-preserved and frozen milk samples. Coliforms and E. coli counts significantly decrease over time after freezing. Consequently, freezing at -20°C could also be appropriate for analysis of mesophilic, thermoduric, and psychrotrophic bacterial groups, but not for coliforms or mammary pathogens. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Cultural and environmental factors affecting the longevity of Escherichia coli in Histosols.
Tate, R L
1978-05-01
The survival of Escherichia coli in organic soils (Histosols) was examined. The death rate of this organism in Pahokee muck was less than that observed in Pompano fine sand. The number of viable E. coli cells found in the muck was approximately threefold greater than that found in the sand following 8 days of incubation. The initial population of the coliform affected the death rate. The rate of loss of viability varied 100-fold when the population size decreased from 2.5 x 10(7) to 3.4 x 10(4). Other factors affecting the viability of E. coli in muck were aerobic versus anaerobic growth of the organism and moist versus flooded conditions in the soil. The greatest survival of the coliform was noted with anaerobically grown cells amended to flooded soil. That the observed decrease in E. coli viability in soil was the result of biotic factors was demonstrated with amendment of sterile soil with E. coli. When 1.1 x 10(5) bacteria per g of soil were added to sterile muck, a population of 3.0 x 10(7) organisms per g of soil developed over a 10-day period. The role of the protozoa in eradication of the coliform from the muck was indicated by a sixfold increase in the protozoan population in natural soil amended with E. coli. Higher organic matter content in a Histosol compared with a mineral soil resulted in an increased survival of the fecal coliforms. Biotic factors are instrumental in the decline in coliform populations, but the potential for growth of the coliform in the organic soil could extend the survival of the organism.
Cultural and Environmental Factors Affecting the Longevity of Escherichia coli in Histosols †
Tate, Robert L.
1978-01-01
The survival of Escherichia coli in organic soils (Histosols) was examined. The death rate of this organism in Pahokee muck was less than that observed in Pompano fine sand. The number of viable E. coli cells found in the muck was approximately threefold greater than that found in the sand following 8 days of incubation. The initial population of the coliform affected the death rate. The rate of loss of viability varied 100-fold when the population size decreased from 2.5 × 107 to 3.4 × 104. Other factors affecting the viability of E. coli in muck were aerobic versus anaerobic growth of the organism and moist versus flooded conditions in the soil. The greatest survival of the coliform was noted with anaerobically grown cells amended to flooded soil. That the observed decrease in E. coli viability in soil was the result of biotic factors was demonstrated with amendment of sterile soil with E. coli. When 1.1 × 105 bacteria per g of soil were added to sterile muck, a population of 3.0 × 107 organisms per g of soil developed over a 10-day period. The role of the protozoa in eradication of the coliform from the muck was indicated by a sixfold increase in the protozoan population in natural soil amended with E. coli. Higher organic matter content in a Histosol compared with a mineral soil resulted in an increased survival of the fecal coliforms. Biotic factors are instrumental in the decline in coliform populations, but the potential for growth of the coliform in the organic soil could extend the survival of the organism. PMID:350158
Lisle, J.T.; Smith, J.J.; Edwards, D.D.; McFeters, G.A.
2004-01-01
McMurdo Station, Antarctica, has discharged untreated sewage into McMurdo Sound for decades. Previous studies delineated the impacted area, which included the drinking water intake, by using total coliform and Clostridium perfringens concentrations. The estimation of risk to humans in contact with the impacted and potable waters may be greater than presumed, as these microbial indicators may not be the most appropriate for this environment. To address these concerns, concentrations of these and additional indicators (fecal coliforms, Escherichia coli, enterococci, coliphage, and enteroviruses) in the untreated wastewater, water column, and sediments of the impacted area and drinking water treatment facility and distribution system at McMurdo Station were determined. Fecal samples from Weddell seals in this area were also collected and analyzed for indicators. All drinking water samples were negative for indicators except for a single total coliform-positive sample. Total coliforms were present in water column samples at higher concentrations than other indicators. Fecal coliform and enterococcus concentrations were similar to each other and greater than those of other indicators in sediment samples closer to the discharge site. C. perfringens concentrations were higher in sediments at greater distances from the discharge site. Seal fecal samples contained concentrations of fecal coliforms, E. coli, enterococci, and C. perfringens similar to those found in untreated sewage. All samples were negative for enteroviruses. A wastewater treatment facility at McMurdo Station has started operation, and these data provide a baseline data set for monitoring the recovery of the impacted area. The contribution of seal feces to indicator concentrations in this area should be considered.
Davis, Jerri V.; Barr, Miya N.
2006-01-01
In 1998, a 5 river-mile reach of the Jacks Fork was included on Missouri's list of impaired waters as required by Section 303(d) of the Federal Clean Water Act. The identified pollutant on the Jacks Fork was fecal coliform bacteria. The length of the impaired reach was changed to 7 miles on the Missouri 2002 303(d) list because of data indicating the fecal coliform bacteria problem existed over a broader area. The U.S. Geological Survey, in cooperation with the National Park Service, conducted a study to better understand the extent and sources of microbiological contamination within the Jacks Fork from Alley Spring to the mouth, which includes the 7-mile 303(d) reach. Ten sites were sampled from June 2003 through October 2003 and from June 2004 through October 2004. Water-column and streambed sediment samples were collected from main-stem and tributary sites mostly during base-flow conditions during a variety of recreational season river uses and analyzed for fecal coliform and Escherichia coli bacteria. Isolates of Escherichia coli obtained from water samples collected at five sites were submitted for rep-PCR analysis to identify presumptive sources of fecal indicator bacteria in the Jacks Fork. Results indicate that recreational users (including boaters and swimmers) are not the primary source of fecal coliform bacteria in the Jacks Fork; rather, the presence of fecal coliform bacteria is associated with other animals, of which horses are the primary source. Increases in fecal coliform bacteria densities in the Jacks Fork are associated with cross-country horseback trail-riding events.
Tiyo, Rogerio; de Souza, Carla Zangari; Nishi, Letícia; Brustolin, Camila Fernanda; Ratti, Bianca Altrão; Falavigna Guilherme, Ana Lucia
2015-01-01
The aim of this work was to compare, from a parasitological ( Cryptosporidium spp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidium spp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardia spp. or Cryptosporidium spp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidium spp. and Giardia spp., as well as artesian wells for coliform control in local production of vegetables to be marketed.
TIYO, Rogerio; de SOUZA, Carla Zangari; NISHI, Letícia; BRUSTOLIN, Camila Fernanda; RATTI, Bianca Altrão; FALAVIGNA GUILHERME, Ana Lucia
2015-01-01
SUMMARY The aim of this work was to compare, from a parasitological ( Cryptosporidiumspp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidiumspp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardiaspp. or Cryptosporidiumspp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidiumspp. and Giardiaspp., as well as artesian wells for coliform control in local production of vegetables to be marketed. PMID:26422158
Blanch, A R; Galofré, B; Lucena, F; Terradillos, A; Vilanova, X; Ribas, F
2007-03-01
To compare the bacterial coliforms detected from occurrences in three zones of a water distribution system supplied by two separate water sources. Conventional and standardized protocols for identifying enterobacterial populations were applied. Additional tests to confirm isolates were included. Analyses of diversity and population similarity were performed using the Phene Plate System, a miniaturized biochemical phenotyping method. Isolates were identified by the API 20E system in tandem with biochemical phenotyping. A total of 16 576 samples were taken from the water distribution system, with 1416 isolates analysed. A low number of coliform occurrences were observed (2%). Escherichia coli was not detected in either water origin or in Zone 2 samples; however, in Zones 1 and 3 a low number of cases of E. coli were recorded. The percentages of E. coli depended on the identification criteria. Eight biochemical profiles for coliform populations were defined according to the results of the confirmative tests. There was a high diversity among these populations in the three zones studied, although no significant variations in their composition (associated with occurrences in the different zones) were observed. Klebsiella oxytoca was the most commonly detected species irrespective of zone, although seven other enterobacterial genera were also found. Analysis of the enzymatic activity of beta-glucuronidase or application of the criteria established in the norm ISO 9308-1, in tandem with thermotolerance was needed to evaluate the occurrence of E. coli in the distribution systems. Detected occurrences of bacterial coliforms could be associated with re-growth patterns for specific sampling points in the distribution system. Seasonal differences, independent of the studied zones, were observed. Biochemical phenotyping of bacterial coliforms was shown to be a useful method on the characterization of occurrences in water distribution systems.
Black, L E; Brion, G M; Freitas, S J
2007-06-01
Predicting the presence of enteric viruses in surface waters is a complex modeling problem. Multiple water quality parameters that indicate the presence of human fecal material, the load of fecal material, and the amount of time fecal material has been in the environment are needed. This paper presents the results of a multiyear study of raw-water quality at the inlet of a potable-water plant that related 17 physical, chemical, and biological indices to the presence of enteric viruses as indicated by cytopathic changes in cell cultures. It was found that several simple, multivariate logistic regression models that could reliably identify observations of the presence or absence of total culturable virus could be fitted. The best models developed combined a fecal age indicator (the atypical coliform [AC]/total coliform [TC] ratio), the detectable presence of a human-associated sterol (epicoprostanol) to indicate the fecal source, and one of several fecal load indicators (the levels of Giardia species cysts, coliform bacteria, and coprostanol). The best fit to the data was found when the AC/TC ratio, the presence of epicoprostanol, and the density of fecal coliform bacteria were input into a simple, multivariate logistic regression equation, resulting in 84.5% and 78.6% accuracies for the identification of the presence and absence of total culturable virus, respectively. The AC/TC ratio was the most influential input variable in all of the models generated, but producing the best prediction required additional input related to the fecal source and the fecal load. The potential for replacing microbial indicators of fecal load with levels of coprostanol was proposed and evaluated by multivariate logistic regression modeling for the presence and absence of virus.
Public Notification - Revised Total Coliform Rule Failure To Report Template
When a PWS fails to report their monitoring results for Total Coliform bacteria, it must issue a public notice to inform consumers of its water of that failure to report. This template can be used as a guide for preparing that public notice.
Microbiological quality of fresh nopal juice
USDA-ARS?s Scientific Manuscript database
Microbial quality of commercially available fresh juices (n=162) made with nopal cactus in Texcoco, State of Mexico, was evaluated during the summer and spring season. All samples contained total coliforms and 91% were positive for Escherichia coli. Although total coliforms and E. coli were detected...
33 CFR 159.127 - Safety coliform count: Recirculating devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety coliform count: Recirculating devices. 159.127 Section 159.127 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159...
33 CFR 159.319 - Fecal coliform and total suspended solids standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... suspended solids standards. 159.319 Section 159.319 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... Certain Alaskan Waters by Cruise Vessel Operations § 159.319 Fecal coliform and total suspended solids... solids greater than 150 mg/l. (b) Graywater effluent discharges. [Reserved] ...
33 CFR 159.319 - Fecal coliform and total suspended solids standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... suspended solids standards. 159.319 Section 159.319 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... Certain Alaskan Waters by Cruise Vessel Operations § 159.319 Fecal coliform and total suspended solids... solids greater than 150 mg/l. (b) Graywater effluent discharges. [Reserved] ...
Mallin, Michael A; Johnson, Virginia L; Ensign, Scott H
2009-12-01
Water quality data at 12 sites within an urban, a suburban, and a rural stream were collected contemporaneously during four wet and eight dry periods. The urban stream yielded the highest biochemical oxygen demand (BOD), orthophosphate, total suspended sediment (TSS), and surfactant concentrations, while the most rural stream yielded the highest total organic carbon concentrations. Percent watershed development and percent impervious surface coverage were strongly correlated with BOD (biochemical oxygen demand), orthophosphate, and surfactant concentrations but negatively with total organic carbon. Excessive fecal coliform abundance most frequently occurred in the most urbanized catchments. Fecal coliform bacteria, TSS, turbidity, orthophosphate, total phosphorus, and BOD were significantly higher during rain events compared to nonrain periods. Total rainfall preceding sampling was positively correlated with turbidity, TSS, BOD, total phosphorus, and fecal coliform bacteria concentrations. Turbidity and TSS were positively correlated with phosphorus, fecal coliform bacteria, BOD, and chlorophyll a, which argues for better sedimentation controls under all landscape types.
Davoodi, Reza; Pirsaheb, Meghdad; Karimyan, Kamaladdin; Gupta, Vinod Kumar; Takhtshahi, Ali Reza; Sharafi, Hooshmand; Moradi, Masoud
2018-06-01
This study was aimed to investigate the distribution of various species of fecal coliform in urban, rural and private drinking water sources of Kermanshah, in the west of Iran. For this study, data of ten years period (2006-2016) assessments of microbial quality regarding various species of Fecal coliforms was taken from health centers associated with urban, rural and private resources of Kermanshah city. A total number of 8643 samples were taken, 1851 samples from rural, 365 from urban and 4834 from private resources. The results showed that Fecal coliforms , Escherichia coli ( E. coli ) had the widest distribution in all urban, rural and private water resources (22.3%, 45.9% and 34%, respectively). Moreover, E. coli (47.5%) and Klebsiella (0.4%) had, respectively, the highest and lowest distribution in all months considered. Based on the results, E.coli exists mostly in water resources; it is therefore of particular importance in the monitoring of water resources.
[Banana peel: a possible source of infection in the treatment of nipple fissures].
Novak, Franz Reis; de Almeida, João Aprígio Guerra; de Souza e Silva, Rosana
2003-01-01
To study the microbiology of banana peel being sold in the city of Rio de Janeiro, in an attempt to determine the possibility that the peel may represent a source of infection for women who use it to treat nipple fissures. The following microorganisms were studied in 20 banana peel samples: mesophiles, total coliforms, fecal coliforms, Pseudomonas aeruginosa, lipolytic and proteolytic microorganisms, molds and yeasts, lactic bacteria, and coagulase-positive staphylococcus. The microbiological analyses revealed the occurrence of several typical groups of microorganisms, with the following distribution of positive results being detected in banana peel samples: mesophiles, 100%; total coliforms, 20%; coagulase-positive staphylococcus, 25%; molds and yeasts, 30%; proteolytic microorganisms, 70%; lipolytic microorganisms, 30%, and lactic bacteria, 95%. Fecal coliforms and Pseudomonas aeruginosa were not isolated. The results show the presence of potentially pathogenic microorganisms in levels which could compromise the microbiological quality of the banana peel. Its use for the treatment of nipple fissures can initiate an infectious process.
Zhang, K; Farahbakhsh, K
2007-06-01
The efficacy of a conventional activated sludge wastewater treatment process and the membrane bioreactor technology in removing microbial pathogens was investigated. Total and fecal coliforms and somatic and F-specific coliphages were used as indicators of pathogenic bacteria and viruses. Up to 5.7 logs removal of coliforms and 5.5 logs of coliphages were observed in the conventional treatment process with advanced tertiary treatment. Addition of chemical coagulants seemed to improve the efficacy of primary and secondary treatment for microorganism removal. Complete removal of fecal coliforms and up to 5.8 logs removal of coliphages was observed in the MBR system. It was shown that the MBR system was capable of high removal of coliphages despite the variation in feed coliphage concentrations. The results of this study indicated that the MBR system can achieve better microbial removal in far fewer steps than the conventional activated sludge process with advanced tertiary treatment. The final effluent from either treatment processes can be potentially reused.
Praveena, Sarva Mangala; Chen, Kwan Soo; Ismail, Sharifah Norkhadijah Syed
2013-11-15
This study aims to determine the concentrations of total coliforms and Escherichia coli (E. coli) in beach water, Teluk Kemang beach. This study was also aimed to determine relationship between total coliforms, E. coli and physicochemical parameters. As perceived health symptoms among beach visitors are rarely incorporated in beach water studies, this element was also assessed in this study. A total of eight water sampling points were selected randomly along Teluk Kemang beach. Total coliforms concentrations were found between 20 and 1940 cfu/100ml. E. coli concentrations were between 0 and 90 cfu/100ml. Significant correlations were found between total coliforms and E. coli with pH, temperature and oxidation reduction potential. Skin and eyes symptoms were the highest reported though in small numbers. Microbiological water quality in Teluk Kemang public beach was generally safe for recreational activities except sampling location near with sewage outfall. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Domek, M.J.; LeChevallier, M.W.; Cameron, S.C.
1984-08-01
Low levels of copper in chlorine-free distribution water caused injury of coliform populations. Monitoring of 44 drinking water samples indicated that 64% of the coliform population was injured. Physical and chemical parameters were measured, including three heavy metals (Cu, Cd, and Pb). Copper concentrations were important, ranging from 0.007 to 0.54 mg/liter. Statistical analyses of these factors were used to develop a model to predict coliform injury. The model predicted almost 90% injury with a copper concentration near the mean observed value (0.158 mg/liter) in distribution waters. Laboratory studies with copper concentrations of 0.025 and 0.050 mg/liter in an inorganicmore » carbon buffer under controlled conditions of temperature and pH caused over 90% injury within 6 and 2 days, respectively. Studies of the metabolism of injured Escherichia coli cells indicated that the respiratory chain is at least one site of damage in injured cells.« less
Jin, Guang; Jeng, Huei-Wang; Bradford, Henry; Englande, A J
2004-01-01
Escherichia coli (E. coli), enterococci, and fecal coliform data were collected and compared as potential indicators for swimmablility assessment of a brackish waterbody (Lake Pontchartrain, Louisiana). These indicators were measured during lake background conditions, in stormwater runoff (before dilution with lake water), and in the outfall plume within the lake following storm events. Microbial indicator titers associated with suspended particles and lake-bottom sediments were also investigated. Overall reduction rate constants for fecal coliform, E. coli, and enterococci in lake water and sediment were measured and reported. Attachment of microbial indicators to suspended matter and subsequent sedimentation appeared to be a significant fate mechanism. A slower reduction rate of indicator organisms in sediment further suggested that bottom sediment may act as a reservoir for prolonging indicator organism survival and added concern of recontamination of overlaying waters due to potential solids resuspension. Results indicated that enterococci might be a more stable indicator than E. coli and fecal coliform and, consequently, a more conservative indicator under brackish water conditions.
Haushild, W.L.; Prych, Edmund A.
1976-01-01
Total- and fecal-coliform bacteria, plus pH, alkalinity, and dissolved inorganic carbon are water-quality parameters that have been added to an existing numerical model of water quality in the salt-wedge reach of the Duwamish River estuary in Washington. The coliform bacteria are modeled using a first-order decay (death) rate, which is a function of the local salinity, temperature, and daily solar radiation. The pH is computed by solving a set of chemical-equilibrium equations for carbonate-bicarbonate buffered aqueous solutions. Concentrations of total- and fecal-coliform bacteria computed by the model for the Duwamish River estuary during June-September 1971 generally agreed with observed concentrations within about 40 and 60 percent, respectively. The computed pH generally agreed with observed pH within about a 0.2 pH unit; however, for one 3-week period the computed pH was about a 0.4 unit lower than the observed pH. (Woodard-USGS)
NASA Technical Reports Server (NTRS)
April, G. C.; Liu, H. A.
1975-01-01
Total coliform group bacteria were selected to expand the mathematical modeling capabilities of the hydrodynamic and salinity models to understand their relationship to commercial fishing ventures within bay waters and to gain a clear insight into the effect that rivers draining into the bay have on water quality conditions. Parametric observations revealed that temperature factors and river flow rate have a pronounced effect on the concentration profiles, while wind conditions showed only slight effects. An examination of coliform group loading concentrations at constant river flow rates and temperature shows these loading changes have an appreciable influence on total coliform distribution within Mobile Bay.
75 FR 18205 - Total Coliform Rule Revisions-Notice of Stakeholder Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-09
... Coliform Rule (RTCR) and the Distribution Systems Research and Information Collection Partnership... reviewing the methods approved to analyze drinking water samples to determine the presence of total... ( [email protected] , (202) 564-1781, Standards and Risk Management Division, Office of Ground Water and...
Harwood, Valerie J.; Whitlock, John; Withington, Victoria
2000-01-01
The antibiotic resistance patterns of fecal streptococci and fecal coliforms isolated from domestic wastewater and animal feces were determined using a battery of antibiotics (amoxicillin, ampicillin, cephalothin, chlortetracycline, oxytetracycline, tetracycline, erythromycin, streptomycin, and vancomycin) at four concentrations each. The sources of animal feces included wild birds, cattle, chickens, dogs, pigs, and raccoons. Antibiotic resistance patterns of fecal streptococci and fecal coliforms from known sources were grouped into two separate databases, and discriminant analysis of these patterns was used to establish the relationship between the antibiotic resistance patterns and the bacterial source. The fecal streptococcus and fecal coliform databases classified isolates from known sources with similar accuracies. The average rate of correct classification for the fecal streptococcus database was 62.3%, and that for the fecal coliform database was 63.9%. The sources of fecal streptococci and fecal coliforms isolated from surface waters were identified by discriminant analysis of their antibiotic resistance patterns. Both databases identified the source of indicator bacteria isolated from surface waters directly impacted by septic tank discharges as human. At sample sites selected for relatively low anthropogenic impact, the dominant sources of indicator bacteria were identified as various animals. The antibiotic resistance analysis technique promises to be a useful tool in assessing sources of fecal contamination in subtropical waters, such as those in Florida. PMID:10966379
Zhang, Chong-Miao; Du, Cong; Xu, Huan; Miao, Yan-Hui; Cheng, Yan-Yan; Tang, Hao; Zhou, Jin-Hong; Wang, Xiao-Chang
2015-01-01
Antibiotic resistance of fecal coliforms in an urban river poses great threats to both human health and the environment. To investigate the occurrence and distribution of antibiotic resistant bacteria in an urban river, water samples were collected from the Chanhe River in Xi'an, China. After membrane filtration of water samples, the tetracycline resistance rate of fecal coliforms and their resistance genes were detected by plating and polymerase chain reaction (PCR), respectively. We found that fecal coliforms were generally resistant to tetracycline and saw average resistance rates of 44.7%. The genes tetA and tetB were widely detected, and their positive rate was 60%-100% and 40%-90%, respectively. We found few strains containing tetC, tetK, tetQ and tetX, and we did not identify any strains containing tetG, tetM or tetO. The prevalence of tetA and tetB over other genes indicated that the main mechanism for resistance to tetracycline is by changes to the efflux pump. Our analysis of the types and proportion of tetracycline resistance genes in the Chanhe River at locations upstream and downstream of the urban center suggests that the increased number of tetracycline-resistant fecal coliforms and spatial variation of tetracycline resistance genes diversity were related to municipal wastewater treatment plant discharge.
Zaleski, Kathleen J.; Josephson, Karen L.; Gerba, Charles P.; Pepper, Ian L.
2005-01-01
This study evaluated the potential for conversion of Class B to Class A biosolids with respect to salmonellae and fecal coliforms during solar drying in concrete lined drying beds. Anaerobically (8% solids) and aerobically (2% solids) digested Class B biosolids were pumped into field-scale drying beds, and microbial populations and environmental conditions were monitored. Numbers of fecal coliforms and salmonellae decreased as temperature and rate of desiccation increased. After 3 to 4 weeks, Class A requirements were achieved in both biosolids for the pathogens and the indicators. However, following rainfall events, significant increase in numbers was observed for both fecal coliforms and salmonellae. In laboratory studies, regrowth of fecal coliforms was observed in both biosolids and biosolid-amended soil, but the regrowth of salmonellae observed in the concrete-lined drying beds did not occur. These laboratory studies demonstrated that pathogens decreased in numbers when soil was amended with biosolids. Based on serotyping, the increased numbers of salmonellae seen in the concrete lined drying beds following rainfall events was most likely due to recolonization due to contamination from fecal matter introduced by animals and not from regrowth of salmonellae indigenous to biosolids. Overall, we conclude that the use of concrete-lined beds created a situation in which moisture added as rainfall accumulated in the beds, promoting the growth of fecal coliforms and salmonellae added from external sources. PMID:16000779
Rainfall-Induced Release of Fecal Coliforms and Other Manure Constituents: Comparison and Modeling▿
Guber, A. K.; Shelton, D. R.; Pachepsky, Y. A.; Sadeghi, A. M.; Sikora, L. J.
2006-01-01
Modeling release of fecal coliforms is an important component of fate and transport simulations related to environmental water quality. Manure constituents other than fecal coliforms may serve as natural tracers of fecal contamination provided that their release from manure to runoff is similar to the fecal coliform release. The objectives of this work were to compare release of fecal coliforms (FC), chloride (Cl−), organic carbon (OC), and water-soluble phosphorus (P) from dissolving manure and to assess the performance of three models in describing the observed release. Bovine manure was applied on 0.5- by 0.3-m bare and vegetated subplots with 20% slope on sandy loam and clay loam soils. Concentrations of Cl−, FC, OC, and P were measured in runoff collected from troughs at the edges of the subplots at 5-min intervals during 1-h rainfall simulations. The one-parametric exponential model and two-parametric Vadas-Kleinman-Sharpley model and Bradford-Schijven model were fitted to the data. The Bradford-Schijven model had uncorrelated parameters, one of which was linearly related to the irrigation rate, and another parameter reflected the presence or the absence of vegetation. Kinetics of the FC release from manure was similar to the release kinetics of P and OC. The Bradford-Schijven model is recommended to simulate the release of manure constituents. PMID:17028232
Microbiological contamination in peanut confectionery processing plants.
Carminati, J de A; Amorim Neto, D P; Morishita, K N; Takano, L V; Olivier Bernardi, A; Copetti, M V; do Nascimento, M da S
2016-10-01
In order to investigate Enterobacteriaceae, coliforms, Escherichia coli and Salmonella contamination, a survey was conducted at three peanut confectionery processing companies (A, B and C) in Brazil. Samples of different peanut confectionery products (n = 59), peanut raw material (n = 30), manufacturing environment (n = 116) and workers' hand surfaces (n = 12) were analysed. Salmonella and E. coli were not detected in any final product or raw material analysed. Enterobacteriaceae was isolated from 15% of final products. Coliforms were detected in only one sample. Referring to the raw material, six samples showed contamination by Enterobacteriaceae and three samples by coliforms. For the process environment, 19% and 11% of samples presented Enterobacteriaceae and coliforms. Escherichia coli was detected in 5% of samples, and one of these samples tested positive for Salmonella; this strain was serotyping as S. Heidelberg. All food handlers surveyed in Company C showed Enterobacteriaceae and coliforms on their hands. Escherichia coli was isolated from one food worker's hand. The results showed that the manufacturing environment, including food handlers were considered the main sources for possible contamination of peanut confectionery products. This has been the first study to investigate the occurrence of Salmonella and other Enterobacteriaceae throughout peanut confectionery processing lines. The results might be used to assist risk assessment studies and to establish more effective control measures. © 2016 The Society for Applied Microbiology.
Hörman, Ari; Hänninen, Marja-Liisa
2006-10-01
In this study we compared the reference membrane filtration (MF) lactose Tergitol-7 (LTTC) method ISO 9308-1:2000 with the MF m-Endo LES method SFS 3016:2001, the defined substrate chromogenic/fluorogenic Colilert 18, Readycult Coliforms and Water Check methods, and ready-made culture media, 3M Petrifilm EC and DryCult Coli methods for the detection of coliforms and Escherichia coli in various water samples. When the results of E. coli detection were compared between test methods, the highest agreement (both tests negative or positive) with the LTTC method was calculated for the m-Endo LES method (83.6%), followed by Colilert 18 (82.7%), Water-Check (81.8%) and Readycult (78.4%), whereas Petrifilm EC (70.6%) and DryCult Coli (68.9%) showed the weakest agreement. The m-Endo LES method was the only method showing no statistical difference in E. coli counts compared with the LTTC method, whereas the Colilert 18 and Readycult methods gave significantly higher counts for E. coli than the LTTC method. In general, those tests based on the analysis of a 1-ml sample (Petrifilm EC and DryCult Coli) showed weak sensitivity (39.5-52.5%) but high specificity (90.9-78.8%).
Mellerup, Anders; Ståhl, Marie
2015-01-01
The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined in the same swine fecal samples. The results showed that the qPCR assays were capable of detecting differences in antibiotic resistance levels in individual animals that the coliform bacteria colony forming units (CFU) could not. Also, the qPCR assays more accurately quantified antibiotic resistance genes when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same samples, and therefore differences in antibiotic resistance levels between samples were more readily detected. To our knowledge, this is the first study to describe sampling and pooling methods for qPCR quantification of antibiotic resistance genes in total DNA extracted from swine feces. PMID:26114765
Wicklein, Shaun M.
2004-01-01
Tributary streamflow to the St. Johns River in Duval County is thought to be affected by septic tank leachate from residential areas adjacent to these tributaries. Water managers and the city of Jacksonville have committed to infrastructure improvements as part of a management plan to address the impairment of tributary water quality. In order to provide data to evaluate the effects of future remedial activities in selected tributaries, major ion and nutrient concentrations, fecal coliform concentrations, detection of wastewater compounds, and tracking of bacterial sources were used to document septic tank influences on the water quality of selected tributaries. The tributaries Fishing Creek and South Big Fishweir Creek were selected because they drain subdivisions identified as high priority locations for septic tank phase-out projects: the Pernecia and Murray Hill B subdivisions, respectively. Population, housing (number of residences), and septic tank densities for the Murray Hill B subdivision are greater than those for the Pernecia subdivision. Water-quality samples collected in the study basins indicate influences from ground water and septic tanks. Estimated concentrations of total nitrogen ranged from 0.33 to 2.86 milligrams per liter (mg/L), and ranged from less than laboratory reporting limit (0.02 mg/L) to 0.64 mg/L for total phosphorus. Major ion concentrations met the State of Florida Class III surface-water standards; total nitrogen and total phosphorus concentrations exceeded the U.S. Environmental Protection Agency Ecoregion XII nutrient criteria for rivers and streams 49 and 96 percent of the time, respectively. Organic wastewater compounds detected at study sites were categorized as detergents, antioxidants and flame retardants, manufactured polycarbonate resins, industrial solvents, and mosquito repellent. The most commonly detected compound was para-nonylphenol, a breakdown product of detergent. Results of wastewater sampling give evidence that stream water in the study basins is affected by septic tank effluent. Fecal coliform bacteria concentrations were measured on a monthly basis; of 115 samples, 63 percent exceeded the State of Florida fecal coliform bacteria standard for Class III surface waters of 800 colonies per 100 milliliters of water on any 1 day. Fecal coliform bacteria concentrations ranged from less than 20 colonies per 100 milliliters of sample to greater than or equal to 160,000 colonies per 100 milliliters of sample. Antibiotic resistance patterns of fecal coliform bacteria were used to identify the sources of fecal coliform bacteria. Significant sources of fecal coliform bacteria included wild animals, dogs, and humans. A majority of the fecal coliform bacteria were classified to be from human sources. Because the primary source of fecal coliform bacteria is from human sources, and most likely septic tank effluent, management of human sources may substantially improve microbiological water quality in both the Fishing Creek and South Branch Big Fishweir Creek basins.
THE TOTAL COLIFORM RULE AND FUTURE OF THE INDICATORS AND PATHOGENS IN DRINKING WATER ASSESSMENT
This presentation describes some of the major microbiological issues related to drinking water quality of concern to the EPA. The revision process of the Total Coliform Rule and the selection of the Microbial Contaminant List (CCL) are discussed. A brief overview of research co...
Fecal coliform (FC) contamination in coastal waters is an ongoing public health problem worldwide. Coastal wetlands and lagoons are typically expected to protect coastal waters by attenuating watershed pollutants including FC bacteria. However, new evidence suggests that coast...
75 FR 14607 - Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0141] Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing...
40 CFR 141.705 - Approved laboratories.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...
40 CFR 141.705 - Approved laboratories.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...
40 CFR 141.705 - Approved laboratories.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...
40 CFR 141.705 - Approved laboratories.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...
40 CFR 141.705 - Approved laboratories.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...
MEMBRANE FILTER PROCEDURE FOR ENUMERATING THE COMPONENT GENERA OF THE COLIFORM GROUP IN SEAWATER
A facile, quantitative, membrane filter procedure (mC) for defining the distribution of coliform populations in seawater according to the component genera was developed. The procedure, which utilizes a series of in situ substrate tests to obviate the picking of colonies for ident...
Method of Detecting Coliform Bacteria and Escherichia Coli Bacteria from Reflected Light
NASA Technical Reports Server (NTRS)
Vincent, Robert (Inventor)
2013-01-01
The present invention relates to a method of detecting coliform bacteria in water from reflected light and a method of detecting Eschericha Coli bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.
Fecal Coliform Determinations. Training Module 5.115.3.77.
ERIC Educational Resources Information Center
Kirkwood Community Coll., Cedar Rapids, IA.
This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining fecal coliform concentrations in a wastewater sample. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…
Total Coliform Determinations. Training Module 5.205.3.77.
ERIC Educational Resources Information Center
Kirkwood Community Coll., Cedar Rapids, IA.
This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining total coliform concentration of a water supply. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…
40 CFR 141.21 - Coliform sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... transit. 3 Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the... total coliform, using lactose broth, is less than 10 percent. 4 If inverted tubes are used to detect gas... negative-rates may be based on lactose fermentation, the rapid test for β-galactosidase and cytochrome...
40 CFR 141.21 - Coliform sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... transit. 3 Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the... total coliform, using lactose broth, is less than 10 percent. 4 If inverted tubes are used to detect gas... negative-rates may be based on lactose fermentation, the rapid test for β-galactosidase and cytochrome...
Van Poucke, S O; Nelis, H J
1995-01-01
We developed a chemiluminometric assay of beta-galactosidase in coliform bacteria, using a phenylgalactose-substituted 1,2-dioxetane derivative as a substrate. Permeabilization of cells is required to ensure the efficient cellular uptake of this compound. By this method, one coliform seeded in 100 ml of sterile water can be detected after a 6- to 9-h propagation phase followed by a 45-min enzyme assay in the presence of polymyxin B. Compared with fluorometry and colorimetry, chemiluminometry afforded 4- and 1,000-fold increases in sensitivity and 1- and 6-h increases in the speed of detection, respectively. PMID:8534120
Radiometric Method for the Detection of Coliform Organisms in Water
Bachrach, Uriel; Bachrach, Zelilah
1974-01-01
A new radiometric method for the detection of coliform bacteria in water has been described. The method is based on the release of 14CO2 from [14C]lactose by bacteria suspended in growth medium and incubated at 37 C. The evolved 14CO2 is trapped by hyamine hydroxide and counted in a liquid scintillation spectrometer. The method permits the detection of 1 to 10 organisms within 6 h of incubation. Coliform bacteria suspended in water for several days recover from starvation and may be quantitated by the proposed method. Bacteria from water samples may also be concentrated by filtration through membrane filters and detected by the radiometric assay. PMID:4605007
The assimilable organic carbon (AOC) and coliform growth response (CGR) are bioassays used to determine water quality. AOC and CGR are better indexes in determining whether water can support the growth of bacteria than biological oxygen demand (BOD). The AOC value of reconditione...
USDA-ARS?s Scientific Manuscript database
Three assays were developed to enumerate total coliforms, Escherichia coli, and total Vibrionaceae in shellfish and other foods and in seawater and other environmental samples. Assays involve membrane overlays of overnight colonies on non-selective agar plates to detect ß-glucuronidase and lysyl am...
33 CFR 159.126 - Coliform test: Type II devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... follows: During each of the 10 test days, one sample must be taken at the beginning, middle and end of an 8-consecutive hour period with one additional sample taken immediately following the peak capacity...: Type II devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...
33 CFR 159.123 - Coliform test: Type I devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... as follows: During each of the 10-test days, one sample must be taken at the beginning, middle, and end of an 8-consecutive hour period with one additional sample taken immediately following the peak...: Type I devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...
Code of Federal Regulations, 2011 CFR
2011-07-01
....018 Fecal Coliform (2) (3) O&G 4 0.012 0.006 TSS 0.044 0.022 1 Pounds per 1000 lbs (or g/kg) of... million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G...
Code of Federal Regulations, 2011 CFR
2011-07-01
....31 Fecal Coliform (2) (3) O&G 4 0.22 0.11 TSS 0.74 0.37 1 Pounds per 1000 lbs (or g/kg) of finished... million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G...
Code of Federal Regulations, 2011 CFR
2011-07-01
....37 Fecal Coliform (2) (3) O&G 4 0.26 0.13 TSS 0.90 0.45 1 Pounds per 1000 lbs (or g/kg) of finished... million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G...
Code of Federal Regulations, 2010 CFR
2010-07-01
....31 Fecal Coliform (2) (3) O&G 4 0.22 0.11 TSS 0.74 0.37 1 Pounds per 1000 lbs (or g/kg) of finished... million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G...
Green, Barbara L.; Clausen, Elizabeth; Litsky, Warren
1975-01-01
Fecal coliform recoveries were determined for six types of membrane filters using 65 nonchlorinated water samples. Results showed that the membranes could be ranked in order of decreasing recovery as follows: Millipore HC > Gelman > Johns-Manville ∼ Sartorius > Millipore HA > Schleicher & Schuell. PMID:1103735
Methods for detecting total coliform bacteria in drinking water were compared using 1483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a ten tube fermentation tube tech...
Microorganisms in stormwater; a summary of recent investigations
Mallard, Gail E.
1980-01-01
All storm runoff contains a variety of bacteria, including total coliform, fecal coliform, and fecal streptococci, which are derived from the land over which the water flows. Most total coliform are native soil organisms, whereas the fecal coliform and fecal streptococci originate from the feces of wild and domestic animals. Urban runoff has been reported to contain pathogenic organisms, but this probably presents little direct threat to human health because the runoff is not ingested. Runoff water can, however, have other negative effects such as contamination of surface water, which may result in beach closures, or contamination of shellfish. This type of contamination is generally of short duration because indicator bacteria and pathogens die out rapidly in the aquatic environment. Similarly, bacteria and viruses deposited on soil by stormwater are inactivated by drying, competition from soil microflora, and a variety of other processes. Every storm producing runoff is unique in the number and type of microorganisms because these vary from site to site, from storm to storm, and during the course of the storm. Stormwater to be examined for microorganisms must be collected in sterile containers and processed immediately. (USGS)
Gil, Ana I; Lanata, Claudio F; Hartinger, Stella M; Mäusezahl, Daniel; Padilla, Beatriz; Ochoa, Theresa J; Lozada, Michelle; Pineda, Ines; Verastegui, Hector
2014-01-01
The study described in this article evaluated sources of contamination of children's food and drinking water in rural households in the highlands of Peru. Samples from children's meals, drinking water, kitchen utensils, and caregivers' and children's hands were analyzed for total coliforms and E. coli counts using Petrifilm EC. Thermotolerant coliforms in water were measured using DelAgua test kits while diarrheagenic E. coli was identified using polymerase chain reaction methods (PCR). Thermotolerant coliforms were found in 48% of all water samples. E. coli was found on 23% of hands, 16% of utensils, and 4% of meals. Kitchen cloths were the item most frequently contaminated with total coliforms (89%) and E. coli (42%). Diarrheagenic E. coli was found in 33% of drinking water, 27% of meals, and on 23% of kitchen utensils. These findings indicate a need to develop hygiene interventions that focus on specific kitchen utensils and hand washing practices, to reduce the contamination of food, water, and the kitchen environment in these rural settings.
Reneau, R B; Pettry, D E; Shanholtz, M I; Graham, S A; Weston, C W
1977-01-01
Distribution of total and fecal coliform bacteria in three Atlantic coastal plain soils in Virginia were monitored in situ over a 3-year period. The soils studied were Varina, Goldsboro, and Beltsville sandy loams. These and similar soils are found extensively along the populous Atlantic seaboard of the United States. They are considered only marginally suitable for septic tank installation because the restricting soil layers result in the subsequent development of seasonal perched water tables. To determine both horizontal and vertical movement of indicator organisms, samples were collected from piezometers placed at selected distances and depths from the drainfields in the direction of the ground water flow. Large reductions in total and fecal coliform bacteria were noted in the perched ground waters above the restricting layers as distance from the drainfield increased. These restricting soil layers appear to be effective barriers to the vertical movement of indicator organisms. The reduction in the density of the coliform bacteria above the restricting soil layers can probably be attributed to dilution, filtration, and dieoff as the bacteria move through the natural soil systems. PMID:325589
Gomes Freitas, Denize; Silva, Rassan Dyego Romão; Bataus, Luis Artur Mendes; Barbosa, Mônica Santiago; da Silva Bitencourt Braga, Carla Afonso; Carneiro, Lilian Carla
2017-02-08
The fecal coliform can contaminate water of human consumption causing problems to public health. Many of these microorganisms may contain plasmid and transfer them to other bacteria. This genetic material may confer selective advantages, among them resistance to antibiotics. The objectives of this study were to analyze the presence of fecal coliforms in water and at drinker surface, to identify the existence of plasmid, conducting studies of resistance to antibiotics, plasmid stability and capacity of bacterial conjugation. Were collected microorganisms in water of drinker surface and were used specific culture media and biochemical tests for identification of organisms, tests were performed by checking the resistance to antibiotics (ampicillin 10 μg, tetracycline 30 μg, and ciprofloxacin 5 μg), was performed extraction of plasmid DNA, plasmid stability and bacterial conjugation. Was obtained results of 31% of Salmonella spp. and 51% for other coliforms. Among the samples positive for coliforms, 27 had plasmid stable and with the ability to perform conjugation. The plasmids had similar forms, suggesting that the resistance in some bacteria may be linked to those genes extra chromosomal.
Dada, E. O.; Ekundayo, F. O.; Makanjuola, O. O.
2014-01-01
This study investigated the antibacterial activities of hot water, ethanol and acetone extracts of Jatropha curcas (LINN) leaves on coliforms isolated from surface waters using growth inhibition indices based on agar plate technique. The percentage recovery of the extracts was 19.17%, 18.10% and 18.80% for hot water, ethanol and acetone respectively. Phytochemical screening of the extracts was also determined. Qualitative phytochemical screening showed that the plant extracts contained steroids, tannins, flavonoids and cardiac glycosides, while alkaloids, phlobatannin, terpenoids and anthraquinones were absent. Only ethanolic extract did not possess saponins. Aqueous extracts of J. curcas compared most favourably with the standard antibiotics (gentamycin) on all the coliform bacteria except on K. pneumoniae and E. coli likely due to a measurably higher antibacterial activity compared to the organic extracts. The minimum inhibitory concentration of the aqueous extract ranged from 3.00 to 7.00 mg/L while minimum bactericidal concentration ranged from 4.00 to 10.00 mg/L. Aqueous extract of J. curcas could be used as antibacterial agents against diseases caused by coliforms. PMID:24711746
The presence of Enterococcus, coliforms and E. coli in a commercial yeast manufacturing process.
O'Brien, S S; Lindsay, D; von Holy, A
2004-07-01
This study evaluated a typical commercial yeast manufacturing process for bacterial contamination. Product line samples of a commercial yeast manufacturing process and the corresponding seed yeast manufacturing process were obtained upstream from the final compressed and dry yeast products. All samples were analysed before (non-PI) and after preliminary incubation (PI) at 37 degrees C for 24 h. The PI procedure was incorporated for amplification of bacterial counts below the lower detection limit. Enterococcus, coliform and Escherichia coli counts were quantified by standard pour-plate techniques using selective media. Presence at all stages and progressive increases in counts of Enterococcus, coliforms and E. coli during processing in the commercial manufacturing operation suggested that the primary source of contamination of both compressed and dry yeast with these bacteria was the seed yeast manufacturing process and that contamination was amplified throughout the commercial yeast manufacturing process. This was confirmed by surveys of the seed yeast manufacturing process which indicated that contamination of the seed yeast with Enterococcus, coliforms and E. coli occurred during scale up of seed yeast biomass destined as inoculum for the commercial fermentation.
Khush, Ranjiv S.; Arnold, Benjamin F.; Srikanth, Padma; Sudharsanam, Suchithra; Ramaswamy, Padmavathi; Durairaj, Natesan; London, Alicia G.; Ramaprabha, Prabhakar; Rajkumar, Paramasivan; Balakrishnan, Kalpana; Colford Jr., John M.
2013-01-01
In this large-scale longitudinal study conducted in rural Southern India, we compared a presence/absence hydrogen sulfide (H2S) test with quantitative assays for total coliforms and Escherichia coli as measures of water quality, health risk, and water supply vulnerability to microbial contamination. None of the three indicators showed a significant association with child diarrhea. The presence of H2S in a water sample was associated with higher levels of total coliform species that may have included E. coli but that were not restricted to E. coli. In addition, we observed a strong relationship between the percent positive H2S test results and total coliform levels among water source samples (R2 = 0.87). The consistent relationships between H2S and total coliform levels indicate that presence/absence of H2S tests provide a cost-effective option for assessing both the vulnerability of water supplies to microbial contamination and the results of water quality management and risk mitigation efforts. PMID:23716404
Sea water quality assessment of Prince Islands' beaches in Istanbul.
Ilter Turkdogan Aydinol, F; Kanat, Gurdal; Bayhan, Hurrem
2012-01-01
In this study, seawater samples were subjected to microbiological and physicochemical analysis (water temperature, pH, Secchi disc depth and ammonia) in the Prince Islands which are located in Marmara Sea, being one of the most popular swimming areas in Istanbul. The monitoring program of the study has been carried out in the summer for 6 weeks at eight stations around the Prince Islands. Measured total coliform values were between 5 ± 2 and 26 ± 55 and faecal coliform values were between 4 ± 2 and 24 ± 50 in the monitoring stations. A statistical study has been conducted to find the relationship between total and faecal coliform concentrations, and t tests were applied. There was no significant difference in each location of the Islands, except one location. The results were evaluated by comparing with national and EU bathing water standards. Results of the study show that deep sea discharges and sea currents contribute dilution of coliform concentration in a positive way, and locations near coastal zones of the islands have acceptable values which are required by the regulations.
Coliform non-compliance nightmares in water-supply distribution systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geldreich, E.E.
1988-01-01
Coliform occurrences in distribution systems have created a great concern for both utilities and water authorities because of the implied public-health implications and failure to meet Federal regulations. Many of the known cases involve systems in the east and midwest. The common denominator being systems that have significant amounts of pipe networks over 75 years old and all are treating surface waters. Origins for these contamination events can be found in source-water fluctuations, failures in treatment-barrier protection, or loss of pipe-network integrity. Once passage into the distribution network has been achieved, some of the coliforms (Klebsiella, Enterobacter, Citrobacter) and othermore » heterotrophic bacteria adapt to the pipe environment, finding protection and nutrient support in pipe sediments. Under conditions of seasonal warm waters (10 degC) and availability of assimilable organics in the pipe sediments and tubercles, colonization grows into biofilms that may slough-off into the water supply, creating a coliform non-compliance problem. Significance of these occurrences and control measures are part of a realistic action plan presented for guidance.« less
NASA Astrophysics Data System (ADS)
Gamazo, Pablo; Colina, Rodney; Victoria, Matias; Alvareda, Elena; Burutatran, Luciana; Ramos, Julian; Olivera, María; Soler, Joan
2015-04-01
In many areas of Uruguay groundwater is the only source of water for human consumption and for industrial-agricultural economic activities. Traditionally considered as a safe source, groundwater is commonly used without any treatment. The Uruguayan law requires bacteriological (fecal) analysis for most water uses, but virological analyses are not mentioned in the legislation. In the Salto district, where groundwater is used for human consumption and for agricultural activities, bacterial contamination has been detected in several wells but no viruses analysis have been performed. The Republic University (UDELAR), with the support of the National Agency for Research and Innovation (ANII), is studying the incidence of virus and fecal bacteria in groundwater on an intensive agriculture area of the Salto district. An initial screening campaign of 44 wells was performed in which, besides total and fecal coliforms, rotavirus and adenovirus were detected. A subgroup of the screening wells (15) where selected for bimonthly sampling during a year. In accordance with literature results, single well data analysis shows that coliform and viral contamination can be considered as independent variables. However, when spatial data is integrated, coliform and viral contamination show linear correlation. In this work we present the survey results, we analyse the temporal incidence of variables like precipitation, temperature and chemical composition in well contamination and we discuss the value of coliforms as global indicator of viral contamination for the Salto aquifer.
Varel, V H; Wells, J E; Shelver, W L; Rice, C P; Armstrong, D L; Parker, D B
2012-04-01
This study evaluated the effect of anaerobic digestion at 22, 38 and 55°C on odour, coliforms and chlortetracycline (CTC) in swine manure or monensin (MON) in cattle manure. Swine or cattle were fed the respective growth promotant, manure was collected, and 2-l laboratory methane digesters were established at the various temperatures and sampled over 25 or 28 days. After 21 days, the concentration of CTC in the 22, 38 and 55°C swine digester slurries decreased 7, 80 and 98%, respectively. Coliforms in the 22°C digester slurries were still viable after 25 days; however, they were not detectable in the 38 and 55°C slurries after 3 and 1 days, respectively. After 28 days, the concentration of MON in the 22, 38 and 55°C cattle digester slurries decreased 3, 8 and 27%, respectively. Coliforms in the 22°C cattle digester slurries were still viable after 28 days; however, they were not detectable in the 38 and 55°C slurries after 14 and 1 days, respectively. These studies indicate that anaerobic digestion at 38 or 55°C may be an effective treatment to reduce coliforms and CTC; however, it is not an effective treatment to reduce MON. More studies are needed to determine which pharmaceuticals are susceptible to degradation by a specific manure treatment to prevent negative environmental consequences. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Health significance and occurrence of injured bacteria in drinking water
NASA Technical Reports Server (NTRS)
McFeters, G. A.; LeChevallier, M. W.; Singh, A.; Kippin, J. S.
1986-01-01
Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.
Whitehead, Paul; Bussi, Gianbattista; Hossain, Mohammed Abed; Dolk, Michaela; Das, Partho; Comber, Sean; Peters, Rebecca; Charles, Katrina J; Hope, Rob; Hossain, Md Sarwar
2018-08-01
River water quality in rapidly urbanising Asian cities threatens to damage the resource base on which human health, economic growth and poverty reduction all depend. Dhaka reflects the challenges and opportunities for balancing these dynamic and complex trade-offs which goals can be achieved through effective policy interventions. There is a serious problem of water pollution in central Dhaka, in the Turag-Tongi-Balu River system in Bangladesh with the river system being one of the most polluted in the world at the moment. A baseline survey of water chemistry and total coliforms has been undertaken and shows dissolved oxygen close to zero in the dry season, high organic loading together with extreme levels of Ammonium-N and total coliform in the water. Models have been applied to assess hydrochemical processes in the river and evaluate alternative strategies for policy and the management of the pollution issues. In particular models of flow, Nitrate-N, Ammonium-N and indicator bacteria (total coliforms) are applied to simulate water quality in the river system. Various scenarios are explored to clean up the river system, including flow augmentation and improved effluent treatment. The model results indicate that improved effluent treatment is likely to have a more significant impact on reducing Ammonium-N and total coliforms than flow augmentation, but a combined strategy would greatly reduce the pollution problems in the Turag-Tongi-Balu River System. Copyright © 2018. Published by Elsevier B.V.
Fatemeh, Dehghan; Reza, Zolfaghari Mohammad; Mohammad, Arjomandzadegan; Salomeh, Kalantari; Reza, Ahmari Gholam; Hossein, Sarmadian; Maryam, Sadrnia; Azam, Ahmadi; Mana, Shojapoor; Negin, Najarian; Reza, Kasravi Alii; Saeed, Falahat
2014-01-01
Objective To analyse molecular detection of coliforms and shorten the time of PCR. Methods Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number (MPN) method for 16 artificial and 101 field samples. The molecular method was also conducted on isolated coliforms from positive MPN samples; standard sample for verification of microbial method certificated reference material; isolated strains from certificated reference material and standard bacteria. The PCR and electrophoresis parameters were changed for reducing the operation time. Results Results of PCR for lacZ and uidA genes were similar in all of standard, operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR. PCR results were confirmed by MPN culture method by sensitivity 86% (95% CI: 0.71-0.93). Also the total execution time, with a successful change of factors, was reduced to less than two and a half hour. Conclusions Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city. It's recommended to be used at least as an initial screening test, and then the positive samples could be randomly tested by MPN. PMID:25182727
Li, Jun; Hao, Haihong; Cheng, Guyue; Wang, Xu; Ahmed, Saeed; Shabbir, Muhammad Abu Bakr; Liu, Zhenli; Dai, Menghong; Yuan, Zonghui
2017-09-15
To investigate the optimal dosage which can improve clinical efficacy and minimize resistance, pharmacokinetics/pharmacodynamics model of enrofloxacin was established. Effect of enrofloxacin treatments on clearance of Salmonella in experimentally infected chickens and simultaneously resistance selection in Salmonella and coliforms were evaluated in three treatment groups (100, PK/PD designed dosage of 4, 0.1 mg/kg b.w.) and a control group. Treatment duration was three rounds of 7-day treatment alternated with 7-day withdrawal. Results showed that 100 mg/kg b.w. of enrofloxacin completely eradicated Salmonella, but resistant coliforms (4.0-60.8%) were selected from the end of the second round's withdrawal period till the end of the experiment (days 28-42). PK/PD based dosage (4 mg/kg b.w.) effectively reduced Salmonella for the first treatment duration. However upon cessation of medication, Salmonella repopulated chickens and persisted till the end with reduced susceptibility (MIC CIP = 0.03-0.25 mg/L). Low frequency (5-9.5%) of resistant coliforms was selected (days 39-42). Enrofloxacin at dosage of 0.1 mg/kg b.w. was not able to eliminate Salmonella and selected coliforms with slight decreased susceptibility (MIC ENR = 0.25 mg/L). In conclusion, short time treatment (7 days) of enrofloxacin at high dosage (100 mg/kg b.w.) could be effective in treating Salmonella infection while minimizing resistance selection in both Salmonella and coliforms.
Retail food safety risks for populations of different races, ethnicities, and income levels.
Signs, Renata J; Darcey, Valerie L; Carney, Trish A; Evans, Alison A; Quinlan, Jennifer J
2011-10-01
Research has found that populations with low socioeconomic status (SES) and minority populations have greater access to small corner markets and less access to supermarkets than high-SES and Caucasian populations. This represents a significant difference in the farm-to-fork continuum that these populations experience. This research examined whether differential retail access to foods results in different food safety risks at the retail level for consumers with different demographics. U.S. Census Bureau census tracts with high African American, Asian, Hispanic, Caucasian, low-SES, and high-SES populations were identified in Philadelphia, PA. Approximately 60 retail food establishments were sampled in each census tract category from June 2008 to June 2010. Food samples collected at stores included milk, eggs, lunchmeat, sandwiches, and ready-to-eat (RTE) fresh fruit, greens, and herbs, when available. With the exception of milk and eggs, only food that had been handled and/or prepared at the retail level was sampled. Food samples were tested for temperature, aerobic plate count, coliforms, fecal coliforms, Escherichia coli, Staphylococcus aureus, and Listeria monocytogenes. The results indicated that internal egg temperatures were higher in samples from low-SES census tracts than in eggs from Caucasian census tracts, and eggs were more often found unrefrigerated in markets in low-SES and Asian census tracts. Milk samples from markets in Hispanic and low-SES census tracts had higher aerobic plate counts than high-SES census tract samples. Sandwiches from markets in high-SES census tracts had higher coliform counts than sandwiches from markets in all other census tract categories. Markets in Asian census tracts had a higher incidence of fecal coliform contamination on sandwiches than markets in Caucasian census tracts. Fecal coliforms were present in a percentage of RTE greens from markets in all census tracts except African American, with the highest percentages of RTE greens positive for fecal coliforms in low-SES (100%), Asian (71.4%), and Caucasian (45.5%) markets.
Mahat, N A; Meor Ahmad, Z; Abdul Wahab, R
2015-09-01
Consumption of iced beverages is common in Malaysia although specific research focusing on its safety parameters such as presence of faecal coliforms and heavy metal elements remains scarce. A study conducted in Kelantan indicated that faecal coliforms were detected in the majority of the ice cube samples analyzed, largely attributable to improper handling. Hence, it was found pertinent to conduct similar study in other parts of the country such as Johor Bahru if the similar pattern prevailed. Therefore, this present cross sectional study which randomly sampled ice cubes from 30 permanent food outlets in Taman Universiti, Johor Bahru for detecting contamination by faecal coliforms and selected heavy metal elements (lead, copper, manganese and zinc) acquires significance. Faecal coliforms were detected in 11 (36.67%) of the samples, ranging between 1 CFU/100 mL to > 50 CFU/100 mL; two of the samples were grossly contaminated (>50 CFU/100 mL). Interestingly, while positive detection of lead was observed in 29 of the 30 ice cube samples (mean: 0.511±0.105 ppm; range: 0.489-0.674 ppm), copper, manganese and zinc were not detected. In addition, analysis on commercially bottled mineral water as well as in tap water samples did not detect such contaminations. Therefore, it appears that (1) contamination of faecal coliforms in ice cubes in food outlets in Malaysia may not be sporadic in pattern but rather prevalent and (2) the source of water used for manufacturing the ice cubes that contained significant amount of lead would suggest that (3) it was neither originated from the treated tap water supply nor bottled mineral water or (4) perhaps contaminated during manufacturing process. Further studies exploring the source of water used for manufacturing these ice cubes as well as the handling process among food operators deserve consideration.
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2012 CFR
2012-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2013 CFR
2013-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2011 CFR
2011-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2014 CFR
2014-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2010 CFR
2010-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
40 CFR 141.805 - Notification to passengers and crew.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...
40 CFR 141.805 - Notification to passengers and crew.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...
40 CFR 432.125 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or... Ammonia (as N) 8.0 4.0 BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147...
40 CFR 432.115 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... Coliform ( 2 ) ( 3 ) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or CFU per 100 mL at... Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147 103 1 mg/L (ppm). 2 Maximum of 400 MPN or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... BOD5 0.56 0.28 Fecal Coliform (2) (3) O&G 4 0.20 0.10 TSS 0.68 0.34 1 Pounds per 1000 lbs (or g/kg) of... million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G...
40 CFR 432.125 - New source performance standards (NSPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or... Ammonia (as N) 8.0 4.0 BOD5 26 16 Fecal Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147...
40 CFR 432.115 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Coliform ( 2 ) ( 3 ) O&G (as HEM) 14 8.0 TSS 30 20 1 mg/L (ppm). 2 Maximum of 400 MPN or CFU per 100 mL at... Coliform (2) (3) O&G (as HEM) 14 8.0 TSS 30 20 Total Nitrogen 147 103 1 mg/L (ppm). 2 Maximum of 400 MPN or...
Particle effects on ultraviolet disinfection of coliform bacteria in recycled water.
Jolis, D; Lam, C; Pitt, P
2001-01-01
Pilot- and bench-scale coliform inactivation tests with UV irradiation were used to show how suspended solids remaining in filtered secondary effluent affect the efficiency of the UV disinfection process. Observed kinetic inactivation rates decreased with increasing suspended particle sizes of 7 microm or larger present in tertiary effluent. First-order inactivation rates estimated from collimated beam dose-response curves for discrete ranges of UV doses were substantially different, which should caution researchers not to compare inactivation data obtained with largely dissimilar UV doses or suspended particle distributions. A dose of approximately 800 J/m2 was identified as the minimum dose that will consistently meet the California wastewater reclamation coliform criterion when applied to in-line filtration effluent.
Evaluation of free-stall mattress bedding treatments to reduce mastitis bacterial growth.
Kristula, M A; Dou, Z; Toth, J D; Smith, B I; Harvey, N; Sabo, M
2008-05-01
Bacterial counts were compared in free-stall mattresses and teat ends exposed to 5 treatments in a factorial study design on 1 dairy farm. Mattresses in five 30-cow groups were subjected to 1 of 5 bedding treatments every other day: 0.5 kg of hydrated limestone, 120 mL of commercial acidic conditioner, 1 kg of coal fly ash, 1 kg of kiln-dried wood shavings, and control (no bedding). Counts of coliforms, Klebsiella spp., Escherichia coli, and Streptococcus spp. were lowest on mattresses bedded with lime. Mattresses bedded with the commercial acidic conditioner had the next lowest counts for coliforms, Klebsiella spp., and Streptococcus spp. Wood shavings and the no-bedding control had the highest counts for coliform and Klebsiella spp. Compared with wood shavings or control, fly ash reduced the counts of coliforms, whereas for the other 3 bacterial groups, the reduction was not always significant. Streptococcus spp. counts were greatest in the control group and did not differ among the shavings and fly ash groups. Teat swab results indicated that hydrated lime was the only bedding treatment that significantly decreased the counts of both coliforms and Klebsiella spp. There were no differences in Streptococcus spp. numbers on the teats between any of the bedding treatments. Bacterial populations grew steadily on mattresses and were generally higher at 36 to 48 h than at 12 to 24 h, whereas bacterial populations on teats grew rapidly by 12 h and then remained constant. Hydrated lime was the only treatment that significantly reduced bacterial counts on both mattresses and teat ends, but it caused some skin irritation.
Survival of fecal coliforms in dry-composting toilets.
Redlinger, T; Graham, J; Corella-Barud, V; Avitia, R
2001-09-01
The dry-composting toilet, which uses neither water nor sewage infrastructure, is a practical solution in areas with inadequate sewage disposal and where water is limited. These systems are becoming increasingly popular and are promoted to sanitize human excreta and to recycle them into fertilizer for nonedible plants, yet there are few data on the safety of this technology. This study analyzed fecal coliform reduction in approximately 90 prefabricated, dry-composting toilets (Sistema Integral de Reciclamiento de Desechos Orgánicos [SIRDOs]) that were installed on the U.S.-Mexico border in Ciudad Juárez, Chihuahua, Mexico. The purpose of this study was to determine fecal coliform reduction over time and the most probable method of this reduction. Biosolid waste samples were collected and analyzed at approximately 3 and 6 months and were classified based on U.S. Environmental Protection Agency standards. Results showed that class A compost (high grade) was present in only 35.8% of SIRDOs after 6 months. The primary mechanism for fecal coliform reduction was found to be desiccation rather than biodegradation. There was a significant correlation (P = 0.008) between classification rating and percent moisture categories of the biosolid samples: drier samples had a greater proportion of class A samples. Solar exposure was critical for maximal class A biosolid end products (P = 0.001). This study only addressed fecal coliforms as an indicator organism, and further research is necessary to determine the safety of composting toilets with respect to other pathogenic microorganisms, some of which are more resistant to desiccation.
Stanley, V G; Gray, C; Daley, M; Krueger, W F; Sefton, A E
2004-01-01
Three trials were conducted to evaluate the effects of lasalocid, an anticoccidial feed additive (90.7 kg/ton); bacitracin, a growth-promoter (50 g/ton); and yeast culture residue (YCR) (1 kg/ton) on the performance of broiler chicks reared to 42 d of age on recycled litter. Recycled litter consisted of pine wood shavings containing droppings from chicks infected with 3 select strains of coccidia (Eimeria tenella, Eimeria maxima, and Eimeria acervulina). Response variables (BW, intestinal tract and litter coliform counts, cecal and liver relative weights, and litter moisture content) were recorded biweekly. Mean BW of chicks fed the diet supplemented with YCR was higher than that of the controls (P < 0.05) and comparable to that of the lasalocid-treated birds in all 3 trials. Mean BW of chicks in all treatment groups decreased uniformly as the litter aged and moisture content increased. The mean intestinal coliform population from YCR-treated chicks was lower (P < 0.05) than those of the control and lasalocid populations. The coliform count was consistently lower than that in chicks on a bacitracin-supplemented diet. Coliform counts from the control and lasalocid-treated birds did not differ. The litter coliform counts increased with increased use of the litter. Cecal and liver relative weights calculated from the chicks in trial 3 showed that only the liver was significantly affected by treatments. YCR appeared to be a viable alternative to bacitracin and lasalocid medication in enhancing growth of broiler chicks reared on recycled litter.
Survival of Fecal Coliforms in Dry-Composting Toilets
Redlinger, Thomas; Graham, Jay; Corella-Barud, Verónica; Avitia, Raquel
2001-01-01
The dry-composting toilet, which uses neither water nor sewage infrastructure, is a practical solution in areas with inadequate sewage disposal and where water is limited. These systems are becoming increasingly popular and are promoted to sanitize human excreta and to recycle them into fertilizer for nonedible plants, yet there are few data on the safety of this technology. This study analyzed fecal coliform reduction in approximately 90 prefabricated, dry-composting toilets (Sistema Integral de Reciclamiento de Desechos Orgánicos [SIRDOs]) that were installed on the U.S.-Mexico border in Ciudad Juárez, Chihuahua, Mexico. The purpose of this study was to determine fecal coliform reduction over time and the most probable method of this reduction. Biosolid waste samples were collected and analyzed at approximately 3 and 6 months and were classified based on U.S. Environmental Protection Agency standards. Results showed that class A compost (high grade) was present in only 35.8% of SIRDOs after 6 months. The primary mechanism for fecal coliform reduction was found to be desiccation rather than biodegradation. There was a significant correlation (P = 0.008) between classification rating and percent moisture categories of the biosolid samples: drier samples had a greater proportion of class A samples. Solar exposure was critical for maximal class A biosolid end products (P = 0.001). This study only addressed fecal coliforms as an indicator organism, and further research is necessary to determine the safety of composting toilets with respect to other pathogenic microorganisms, some of which are more resistant to desiccation. PMID:11526002
Korir, Robert Cheruiyot; Parveen, Salina; Hashem, Fawzy; Bowers, John
2016-06-01
The aim of this study was to investigate the microbiological quality of six types of fresh produce obtained from three retail stores located on the Eastern Shore of Maryland, USA. A total of 414 samples representing basil, cilantro, lettuce, scallion, spinach, and parsley were analyzed for total aerobic bacteria (APC), total coliforms, Escherichia coli, and three pathogenic bacteria (E. coli O157:H7, Listeria monocytogenes, and Salmonella), using standard methods. Presumptive pathogenic isolates were confirmed using BAX Polymerase Chain Reaction. Total aerobic populations varied widely between samples, while 38.41% were positive for total coliforms and only 10.15% for E. coli. Median abundance (log CFU/g) of total coliforms and E. coli were less than the limit of detection and that of APC ranged from 5.78 to 6.61 over the six produce types. There was a statistically significant difference in prevalence of total coliforms among the retail stores, but not for abundance of APC or prevalence of E. coli. E. coli O157:H7 and L. monocytogenes were detected in one spinach sample each, while one parsley and one cilantro sample were positive for Salmonella. There were no statistically significant differences in microbiological quality among produce types. Although the results of this study provided some indices of sanitary and/or spoilage level, no relationship was observed among the total aerobic bacteria, total coliforms, E. coli, and the presence of pathogenic bacteria in the samples tested. Copyright © 2015 Elsevier Ltd. All rights reserved.
A new membrane filter agar medium (MI agar) containing a chromogen, indoxyl-beta-D-glucuronide, and a fluorogen, 4-methylumbelliferyl-beta-D-galactopyranoside, was developed to simultaneously detect and enumerate Escherichia coli and total coliforms (TC) in water samples on the b...
Code of Federal Regulations, 2014 CFR
2014-07-01
... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...
Code of Federal Regulations, 2013 CFR
2013-07-01
... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...
40 CFR 141.202 - Tier 1 Public Notice-Form, manner, and frequency of notice.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fecal coliform or E. coli are present in the water distribution system (as specified in § 141.63(b)), or when the water system fails to test for fecal coliforms or E. coli when any repeat sample tests...) Detection of E. coli, enterococci, or coliphage in source water samples as specified in § 141.402(a) and...
40 CFR 141.202 - Tier 1 Public Notice-Form, manner, and frequency of notice.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fecal coliform or E. coli are present in the water distribution system (as specified in § 141.63(b)), or when the water system fails to test for fecal coliforms or E. coli when any repeat sample tests...) Detection of E. coli, enterococci, or coliphage in source water samples as specified in § 141.402(a) and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
...--Wilson-Clinton Hwy to Fecal Coliform entrance of White Bayou (East Baton Rouge Parish) (Scenic). 040103 Comite River--Entrance of White Bayou to Fecal Coliform. Amite River. 040201 Bayou Manchac--Headwaters to.... Canal to mouth at Lake Maurepas (Scenic). 040903 Bayou Cane--Headwaters to U.S. Hwy 190 TSS. (Scenic...
Grey water characterization and treatment for reuse in an arid environment.
Smith, E; Bani-Melhem, K
2012-01-01
Grey water from a university facilities building in Cairo, Egypt was analysed for basic wastewater parameters. Mean concentrations were calculated based on grab samples over a 16-month period. Values for chemical oxygen demand (COD) and nutrients exceeded values reported in a number of other studies of grey water, while coliform counts were also high. A submerged membrane bioreactor (SMBR) system using a hollow fibre ultrafiltration membrane was used to treat the grey water with the aim of producing effluent that meets reuse guidelines for agriculture. A test run for 50 days at constant transmembrane pressure resulted in very good removal for key parameters including COD, total suspended solids (TSS), colour, turbidity, ammonia nitrogen, anionic surfactants, and coliform bacteria. High standard deviations were observed for COD and coliform concentrations for both monthly grab samples and influent values from the 50-day SMBR experiment. SMBR effluent meets international and local guidelines for at least restricted irrigation, particularly as pertains to COD, TSS, and faecal coliforms which were reduced to mean treated values of 50 mg/L, 0 mg/L (i.e., not detected), and <50 cfu/100 mL, respectively.
Ultraviolet (UV) disinfection of grey water: particle size effects.
Winward, G P; Avery, L M; Stephenson, T; Jefferson, B
2008-02-01
The impact of water quality on the ultraviolet (UV) disinfection of grey water was investigated with reference to urban water reuse. Direct UV disinfection of grey water did not meet the stringent California State Title 22 criteria for unrestricted urban water reuse due to the presence of particulate material ranging from < 1 to > or = 2000 microm in size. Grey water was manipulated by settling to produce fractions of varying particle size distributions and blending was employed post-disinfection to extract particle-associated coliforms (PACs). The efficacy of UV disinfection was found to be linked to the particle size of the grey water fractions. The larger particle size fractions with a mean particle size of 262 microm and above were observed to shield more coliforms from UV light than did the smaller particles with a mean particle size below 119 microm. Up to 70% of total coliforms in the larger particle size fractions were particle-associated following a UV dose (fluence) of 260 mJ.cm(-2) and would remain undetected by standard coliform enumeration techniques. Implications for urban water reuse are discussed and recommendations made for grey water treatment to ensure removal of particle-associated indicator bacteria and pathogens prior to UV disinfection.
Tsega, N; Sahile, S; Kibret, M; Abera, B
2013-12-01
Accesses to safe water is a universal need however, many of the world's population lack access to adequate and safe water. Consumption of water contaminated causes health risk to the public and the situation is serous in rural areas. To assess the bacteriological and physico-chemical quality of drinking water sources in a rural community of Ethiopia. Water samples were collected from tap, open springs, open dug wells and protected springs for bacteriological analysis of total coliforms and thermotolerant coliforms. The turbidity, pH and temperature were measured immediately after collection. Most drinking water sources were found to have coliform counts above the recommended national and international guidelines and had high sanitary risk scores. There was a statistically significant difference among water sources with respect to TC and TTC (p < 0.05) and there was a statistically significant positive correlation between coliform counts and sanitary risk scores (p < 0.01). Most water sources didn't satisfy the turbidity values recommended by WHO. The water sources were heavily contaminated which suggested poor protection and sanitation practice in the water sources. Source protection strategies as well as monitoring are recommend for this community.
[Spring water quality assessment regarding the problem of endemic fluorosis].
Leshchenko, D V; Mialo, O A; Beliakova, M B; Beliaeva, E A; Samoukina, A M; Chervinets, Iu V; Ivanova, O V
2013-01-01
A possible variant for reducing the consumption of fluoride by population of Tver region is the use of water with low fluoride content, such as spring water. Assessment of drinking suitability of spring water (the content of physiologically important mineral elements and microbial purity) is relevant to our region. Water samples from 6 spring-water source of Tver region were studied during the year. The content of fluoride and calcium were measured by using an ion-selective electrodes. Microbiological purity tested by the presence of total coliform bacteria, thermotolerant coliform bacteria, coliphages and total microbial numbers. The analysis of some mineral components in spring water of Tver region showed that calcium content was in range 33-88 mg/l, that satisfied the recommended value; fluoride concentration is less then 0.5 mg/l. In all spring water samples total coliforms, thermotolerant coliforms and coliphages were absent. The total microbial number was in standard range, except of two spring-water source in the autumn and summer. The data suppose that spring water of Tver region can be used as a component of diet normalizing the fluoride consumption at risk of dental fluorosis in children.
1980-01-01
In a multi-laboratory trial with the membrane filtration technique, three surfactants--Teepol 610 (T610), Tergitol 7 (T7) and sodium lauryl sulphate (LS)--were compared in media for the enumeration of coliform organisms and Escherichia coli in water. A total of 179 samples of water (87 raw and 92 marginally chlorinated) were examined for colony counts of coliform organisms, and 185 water samples (94 raw and 91 marginally chlorinated) for E. coli. Slight differences in the confirmed colony counts between the three media were noted, but few of these were observed consistently in every laboratory. In most laboratories, T7 gave slightly higher counts of E. coli than LS with chlorinated waters; a higher incidence of false-positive results for E. coli at 44 degrees C was also noted with T7. As there were no outstanding differences in the trial, sodium lauryl sulphate, which is chemically defined, cheap and readily available, is therefore recommended for use at a concentration of 0 . 1% instead of Teepol 610 in the standard medium for the enumeration of coliform organisms and E. coli in water by the membrane filtration technique. PMID:7005324
Photocatalytic degradation of E. coliform in water.
Sun, Darren Delai; Tay, Joo Hwa; Tan, Koh Min
2003-08-01
This study aims to further investigate the total mineralization of the bacteria to the extent of death and cell-mass inactivation using a TiO2-Fe2O3 membrane photocatalytic oxidation reactor. Experimental results clearly indicated that dissolved oxygen (DO), hydraulic retention time (HRT) and concentration of the model bacteria (Escherichia coliform) affected the removal efficiency. It was found that the ultimate removal efficiency was 99% at DO level of 21.34 mg/l, HRT at 60s and high concentration of E. coli at 10(9)CFU/ml. The morphologic studies also showed that E. coliform could be further mineralized into CO2 and H2O. Dissolved organic carbon, pH and gas chromatograph analysis had justified most importantly the evolution of CO2. Experimental results revealed that the photomineralization rate of E. coliform followed pseudo-first-order kinetics by the role of DO. The derived empirical models were found consistent with the proposed reaction pathways of a combined UV breakdown on mass cell and a dual-site Langmuir-Hinshelwood mechanism where the rate-controlling step is the surface interaction between the adsorbed cleavage bacterial cells and hydroxyl radicals.
Microbiological quality and safety of cooking butter in Beni-Suef governorate-Egypt.
Meshref, A M S
2010-06-01
Cooking butter is one of the most popular types of fat consumed in Egyptian houses. It is produced in villages by rural women that are usually using their traditional knowledge during manufacturing. To study the rate of contamination and hygienic quality of cooking butter A total of 60 random samples of cooking butter, were collected from different farmers' houses in different villages, Beni-Suef Governorate, Egypt. Cooking butter samples were examined for psychrotrophic bacteria, total coliforms, faecal coliforms and molds and yeasts counts. Additionally examination for the presence of pathogenic bacteria like E.coli, S.aureus and Ps.aeruginosa were also performed. The microbiological examination revealed that 100, 100, 36.7, 31.7, 31.7 and 23.3% of the examined samples were contaminated by psychrotrophic bacteria, molds and yeasts, coliforms, faecal coliforms, E.coli and S.aureus, respectively. None of the examined cooking butter samples contained Ps.aeruginosa. The means values of sodium chloride and titratable acidity were 0.57 ± 0.05 % and 0.20 ± 0.013%, respectively. The present study showed that cooking butter is produced under unhygienic condition and without good manufacturing practice. The Public health significance and suggestive control measures are discussed.
Sanitary quality of the Jordan River in Salt Lake County, Utah
Thompson, K.R.
1984-01-01
This investigation of the sanitary quality of the Jordan River was conducted from July 1980 to October 1982 using indicator bacteria rather than specific pathogens. A serious sanitary problem was identified. Concentrations of total coliform bacteria often exceeded 5,000 colonies per 100 milliliters and concentrations of fecal coliform bacteria often exceeded 2,000 colonies per 100 milliliters in the lower reaches of the river. At times these levels were greatly exceeded. The most conspicuous aspect of the bacteriological data is its extreme variability. Seven waste-water treatment plants, seven major tributaries, numerous storm conduits, irrigation-return flow, and other sources all contribute to the dynamic system that determines the sanitary quality of the river. Because of this variability the sanitary quality of the river cannot be predicted at any one time. In general, concentrations of all three indicator bacteria increased in a downstream direction. Storm runoff from urban areas contributed large concentrations of indicator bacteria to the river. Regression analysis of 9 years of data collected at 1700 South Street showed a significant positive correlation between both fecal coliform and fecal streptococcal concentrations versus time. Concentrations of fecal coliform and fecal streptococci have both been increasing since 1974 at 1700 South Street. (USGS)
Myers, Donna N.
1992-01-01
This report presents the results of a study by the U.S. Geological Survey, in cooperation with the City of Columbus, Ohio, to determine the distribution and variability of fecal-indicator bacteria in Scioto and Olentangy Rivers. Fecal-indicator bacteria are among the contaminants of concern to recreational users of these rivers in the Columbus area. Samples were collected to be analyzed for fecal-coliform and Escherichia coli (E. coli) bacteria and selected water-quality constituents and physical properties at 10 sites-- 4 on the Olentangy River and 6 on the Scioto River during the recreational seasons in 1987, 1988, and 1989. Measurements of streamflow also were made at these sites at various frequencies during base flow and runoff. The concentrations of fecal-coliform and E. coli bacteria in the Scioto and Olentangy Rivers spanned a range of five orders of magnitude, from less than 20 to greater than 2,000,000 col/100 mL (colonies per 100 milliliters). In addition, the concentrations of fecal coliform and E. coli bacteria are well correlated (r=0.97) in the study area. At times, relatively high concentrations, for fecal-indicator bacteria (concentrations greater than 51,000 col/100 mL for fecal-coliform and E. coli ) were found in Olentangy River at Woody Hayes Drive and at Goodale Street, and in Scioto River at Greenlawn Avenue and at Columbus. Intermediate concentrations of fecal-indicator bacteria (from 5,100 to 50,000 col/100 mL for fecal coliform and (from 510 to 50,000 col/100 mL for E. coli ) were found in Scioto River at Town Street and below O'Shaughnessy Dam near Dublin, Ohio, and in Olentangy River at Henderson Road. The lowest (median) concentrations of fecal-indicator bacteria (from 20 to 5,000 col/100 mL for fecal coliform and from 20 to 500 col/100 mL for E. coli ) were found at Olentangy River near Worthington, Ohio, Scioto River at Dublin Road Water Treatment Plant and below Griggs Reservoir. Fecal-coliform concentrations exceeded the geometric mean and single-sample Ohio Water Quality Standards for recreation less frequently than E. coli concentrations. The E. coli numerical water-quality standards are more difficult to meet than the fecal coliform standards because they are as much as an order of magnitude lower in some instances. The geometric mean bathing-water and primary-contact standards for fecal-coliform and E. coli bacteria were exceeded in more samples for Olentangy River at Goodale Street than for any other site. The single-sample bathing-water standard for fecal-coliform bacteria was exceeded in 83 percent of all samples and for E. coli in 91 percent of samples for Olentangy River at Goodale Street. Compared to Olentangy River at Goodale Street, geometric means and single-samples exceeded the bathing-water standards somewhat less frequently for Scioto River at Town Street and far less frequently for Scioto River at Dublin Road Water Treatment Plant. In contrast to results for fecal-indicator bacteria, the differences between sites for pH and for concentrations for total alkalinity, total chloride, total nonfilterable residue, total nitrate plus nitrite as nitrogen, total phosphorus, and total organic carbon were small. The large contribution of streamflow and discharge of fecal-indicator bacteria from Olentangy River to Scioto River has a major effect on the Scioto River downstream from the confluence of Olentangy River during periods of rainfall and runoff. Fecal-indicator discharges were calculated for times before, during, and at 24-hour intervals for 48 to 72 hours after two runoff-producing storms. Fecal-coliform and E. coli concentrations were lower in samples collected before runoff and during receding streamflows at 24- to 48-hours after the storms than in samples collected during runoff. The fecal-indicator discharges entering Scioto River from Olentangy River ranged from 22.6 to nearly 100 percent of the total for two storms studied. Controlling nonpoint, unregulated,
Parker, W F; Mee, B J
1982-01-01
The survival of Salmonella adelaide and fecal coliforms in two coarse sands influenced by two sources of septic tank effluent was studied. The experiments were conducted in conditions that reflected the soil environment beneath functioning septic tank systems. Significant differences in survival were found with different effluent sources. In one experiment the survival of S. adelaide was similar to that of fecal coliforms; in the other it was not. The nonuniform, multiphasic nature of survival curves was variability observed in these experiments suggests that the application of such survival data for establishing management criteria for septic tank systems--by, for example, the use of soil moisture characteristic curves to give estimates of movement in the soil--is inappropriate. PMID:7103482
Hussong, D; Damaré, J M; Limpert, R J; Sladen, W J; Weiner, R M; Colwell, R R
1979-01-01
Quantitative and qualitative analyses of the intestinal bacterial flora of Canada geese and whistling swans were carried out with the finding that wild birds harbor significantly more fecal coliforms than fecal streptococci. The reverse was typical of captive and fasting birds. Neither Salmonella spp. nor Shigella spp. were isolated from 44 migratory waterfowl that were wintering in the Chesapeake Bay region. Enteropathogenic Escherichia coli were detected in seven birds. Geese eliminated 10(7) and swans 10(9) fecal coliforms per day. Results of in situ studies showed that large flocks of waterfowl can cause elevated fecal coliform densities in the water column. From the data obtained in this study, it is possible to predict the microbial impact of migratory waterfowl upon aquatic roosting sites. PMID:104659
The ultraviolet absorbance spectrum of coliform bacteria and its relationship to astronomy
NASA Astrophysics Data System (ADS)
Hoyle, F.; Wickramasinghe, N. C.; Jansz, E. R.; Jayatissa, P. M.
1983-09-01
The ultraviolet absorbance spectrum of a mixed culture of coliform bacteria is obtained and compared to recent measurements of the extinction curve of starlight. The absorbance of the bacterial suspensions over the wavebands 3500-2000 A and 7000-3400 A are presented along with a comparison of the extinction values for the star HD 14250 with the alpha function of the coliform suspension, which is a measure of the total amount of the material in the line of sight of the star. The agreement is excellent and is just as good as the agreement obtained by Karim et al. (1983) for typtophan in isolation, supporting the contention that the tryptophan responsible for the astronomical extinction is present in the interstellar grains in protein form.
Kameyama, Mitsuhiro; Chuma, Takehisa; Nishimoto, Tadahiro; Oniki, Hiroyuki; Yanagitani, Yasuo; Kanetou, Ryouichi; Gotou, Kouichi; Shahada, Francis; Iwata, Hiroyuki; Okamoto, Karoku
2012-01-01
To evaluate the effect of cooled and chlorinated chill water for Campylobacter and coliforms at a middle-size processing plant which was considered to be difficult for eliminate pathogenic bacteria on carcasses, following three conditions were examined; keeping temperature at < 20, < 10 and < 10°C, and chlorine concentration at < 50, < 50 and 50 to 70 ppm during processing in experiment 1, 2 and 3 respectively. Fifteen prechill and 15 postchill carcasses were examined in each experiment. In lower temperature of experiment 2, decreasing rate (%) of coliforms was significantly higher (P<0.01) than that in experiment 1. In higher chlorination of experiment 3, no Campylobacter was detected from all postchill carcasses.
Wang, Dunling; Fiessel, Wanda
2008-01-01
This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coli in drinking water samples with a standard membrane filtration procedure. The experiment indicated that the differential coliform agar (DCA) medium was the most effective among the tested media in enumerating TC and E. coli, without the need for extensive accompanying confirmation tests. The results for DCA medium were highly reproducible for both TC and E. coli with standard deviation of 6.0 and 6.1, respectively. A high agreement (82%) was found between DCA and m-Endo media on 152 drinking water samples in terms of TC positive. The DCA medium also reduced concealment of background bacteria.
Zimmerman, Tammy M.; Zimmerman, Michele L.; Lindsey, Bruce D.
2001-01-01
Total coliform and Escherichia coli (E. coli) bacteria were analyzed in ground water sampled from 78 private household-supply wells as part of a study by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Environmental Protection to evaluate the relation between well construction characteristics and the occurrence of bacteria in ground water. Sampling was done in eight counties in south-central and southeastern Pennsylvania from September 2000 to March 2001. All samples were collected from wells in close proximity to agricultural land-use areas.Total coliform bacteria were found in water from 62 percent (48 of 78) of the wells, and bacteria were just as likely to be found in sanitary wells (grouted/loose-fitting well cap or grouted/sanitary sealed well cap) as in nonsanitary wells (nongrouted/ loose-fitting well cap). The areas underlain by carbonate bedrock had the highest percentages of total coliform detected (about 75 percent). Nearly half of the samples collected in the areas underlain by noncarbonate bedrock also were found to have total coliform present. E. coli bacteria were found in water from 10 percent of the wells. Seventeen percent of the samples that were positive for total coliform also were positive for E. coli. The presence of E. coli bacteria was more likely in water from nonsanitary wells. Additionally, the presence of E. coli bacteria was more likely in ground water from wells underlain by carbonate bedrock. A further breakdown of the data into four groups on the basis of sanitary construction and bedrock type indicated the presence of E. coli was more likely in water from nonsanitary wells in areas underlain by carbonate bedrock.Statistical analysis of other well-construction characteristics that might relate to occurrence of bacteria showed that the presence of total coliform bacteria was related to the depth to water-bearing zone in both sanitary and nonsanitary wells in areas underlain by carbonate bedrock. Relations also are present between the presence of total coliform bacteria and casing length in nonsanitary wells in areas underlain by noncarbonate bedrock. Bacteria were found in wells both with and without insects observed on the underside of the well cap. Because of the small number of wells sampled that had sanitary sealed caps, it is uncertain whether installation of sanitary sealed well caps would reduce the incidence of bacteria in ground water from wells or if the presence of bacteria is because of a combination of well-construction characteristics or aquifer-wide contamination of limited or broad areal extent.
ERIC Educational Resources Information Center
Omarova, Mariya N.; Orakbay, Lyazzat Zh.; Shuratov, Idelbay H.; Kenjebayeva, Asiya T.; Zhumagalieva, Aizhan B.; Sarsenova, Ainur B.
2016-01-01
The paper is devoted to monitoring the environmental coliform bacteria (CB) contamination (soil and water) in the environmental disaster areas in the Kazakhstan part of the Aral Sea Region and ranking districts by their level of contamination and the rate of gastrointestinal infections (GI). The research was done in environmental disaster areas…
Habash, Marc; Johns, Robert
2009-10-01
This study compared an automated Escherichia coli and coliform detection system with the membrane filtration direct count technique for water testing. The automated instrument performed equal to or better than the membrane filtration test in analyzing E. coli-spiked samples and blind samples with interference from Proteus vulgaris or Aeromonas hydrophila.
Lewis, D J; Atwill, E R; Lennox, M S; Hou, L; Karle, B; Tate, K W
2005-08-01
How and where to improve water quality within an agricultural watershed requires data at a spatial scale that corresponds with individual management decision units on an agricultural operation. This is particularly true in the context of water quality regulations, such as Total Maximum Daily Loads (TMDLs), that identify agriculture as one source of non-point source pollution through larger tributary watershed scale and above and below water quality investigations. We have conducted a systems approach study of 10 coastal dairies and ranches to document fecal coliform concentration and loading to surface waters at the management decision unit scale. Water quality samples were collected on a storm event basis from loading units that included: manure management systems; gutters; storm drains; pastures; and corrals and lots. In addition, in-stream samples were collected above and below the dairy facilities and from a control watershed, managed for light grazing and without a dairy facility or human residence and corresponding septic system. Samples were analyzed for fecal coliform concentration by membrane filtration. Instantaneous discharge was measured for each collected sample. Storm runoff was also calculated using the curve number method (SCS, 1985). Results for a representative dairy as well as the entire 10 dairy data set are presented. Fecal coliform concentrations demonstrate high variability both within and between loading units. Fecal coliform concentrations for pastures range from 206 to 2,288,888 cfu/100 ml and for lots from 1,933 to 166,105,000 cfu/100 ml. Mean concentrations for pastures and lots are 121,298 (SE = 62,222) and 3,155,584 (SE = 1,902,713) cfu/100 ml, respectively. Fecal coliform load from units of concentrated animals and manure are significantly more than units such as pastures while storm flow amounts were significantly less. Compared with results from earlier tributary scale studies in the watershed, this systems approach has generated water quality data that is beneficial for management decisions because of its scale and representation of current management activities. These results are facilitating on-farm changes through the cooperative efforts of dairy managers, regulatory agency staff, and sources of technical and financial assistance.
Kutto, E K; Ngigi, M W; Karanja, N; Kange'the, E; Bebora, L C; Lagerkvist, C J; Mbuthia, P G; Njagi, L W; Okello, J J
2011-02-01
To assess the microbiological safety of kale (Brassica oleracea Acephala) produced from farms and those sold at the markets with special focus on coliforms, E.coli and Salmonella. A cross sectional study. Peri-Urban farms (in Athi River, Ngong and Wangige), wet markets (in Kawangware, Kangemi and Githurai), supermarkets and high-end specialty store both within Nairobi city. Mean coliform count on vegetables from farms were 2.6 x 10(5) +/- 5.0 x 10(5) cfu/g while those from the wet markets were 4.6 x 10(6) +/- 9.1 x 10(6) cfu/g, supermarkets, 2.6 x 10(6) +/- 2.7 x 10(6) and high-end specialty store 4.7 x 10(5) +/- 8.9 x 10 (5). Coliform numbers obtained on kales from the wet markets and supermarkets were significantly higher (p < 0.05) compared to those from farms, while kale samples purchased from high-end specialty store had similar levels of coliform loads as those from the farms. E. coli prevalence in the wet markets, supermarkets and high-end specialty store were: 40, 20 and 20%, respectively. Salmonella was detected on 4.5 and 6.3% of samples collected from the farms in Wangige and wet market in Kawangware, respectively. Fecal coliforms in water used on farms (for irrigation) and in the markets (for washing the vegetables) exceeded levels recommended by World Health Organization (WHO) of 10(3) organisms per 100 milliliter while Salmonella was detected in 12.5% of washing water samples collected from Kangemi market. Poor cultivation practices and poor handling of vegetables along the supply chain could increase the risk of pathogen contamination thus puting the health of the public at risk, therefore good agricultural and handling practices should be observed.
Evaluation of free-stall mattress bedding treatments to reduce mastitis bacterial growth
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kristula, M.A.; Dou, Z.; Toth, J.D.
2008-05-15
Bacterial counts were compared in free-stall mattresses and teat ends exposed to 5 treatments in a factorial study design on 1 dairy farm. Mattresses in five 30-cow groups were subjected to 1 of 5 bedding treatments every other day: 0.5 kg of hydrated limestone, 120 mL of commercial acidic conditioner, 1 kg of coal fly ash, 1 kg of kiln-dried wood shavings, and control (no bedding). Counts of coliforms, Klebsiella spp., Escherichia coli, and Streptococcus spp. were lowest on mattresses bedded with lime. Mattresses bedded with the commercial acidic conditioner had the next lowest counts for coliforms, Klebsiella spp., andmore » Streptococcus spp. Wood shavings and the no-bedding control had the highest counts for coliform and Klebsiella spp. Compared with wood shavings or control, fly ash reduced the counts of coliforms, whereas for the other 3 bacterial groups, the reduction was not always significant. Streptococcus spp. counts were greatest in the control group and did not differ among the shavings and fly ash groups. Teat swab results indicated that hydrated lime was the only bedding treatment that significantly decreased the counts of both coliforms and Klebsiella spp. There were no differences in Streptococcus spp. numbers on the teats between any of the bedding treatments. Bacterial populations grew steadily on mattresses and were generally higher at 36 to 48 h than at 12 to 24 h, whereas bacterial populations on teats grew rapidly by 12 h and then remained constant. Hydrated lime was the only treatment that significantly reduced bacterial counts on both mattresses and teat ends, but it caused some skin irritation.« less
Effects of cattle manure on erosion rates and runoff water pollution by faecal coliforms.
Ramos, M C; Quinton, J N; Tyrrel, S F
2006-01-01
The large quantities of slurry and manure that are produced annually in many areas in which cattle are raised could be an important source of organic matter and nutrients for agriculture. However, the benefits of waste recycling may be partially offset by the risk of water pollution associated with runoff from the fields to which slurry or manure has been applied. In this paper, the effects of cattle manure application on soil erosion rates and runoff and on surface water pollution by faecal coliforms are analysed. Rainfall simulations at a rate of 70 mm h(-1) were conducted in a sandy loam soil packed into soil flumes (2.5m long x 1m wide) at a bulk density of 1400 kg m(-3), with and without cattle slurry manure applied on the surface. For each simulation, sediment and runoff rates were analysed and in those simulations with applied slurry, presumptive faecal coliform (PFC) concentrations in the runoff were evaluated. The application of slurry on the soil surface appeared to have a protective effect on the soils, reducing soil detachment by up to 70% but increasing runoff volume by up to 30%. This practice implies an important source of pollution for surface waters especially if rainfall takes place within a short period after application. The concentrations of micro-organisms (presumptive faecal coliforms (PFCs)) found in water runoff ranged from 1.9 x 10(4) to 1.1 x 10(6) PFC 100mL(-1), depending on the initial concentration in the slurry, and they were particularly high during the first phases of the rainfall event. The result indicates a strong relationship between the faecal coliforms transported by runoff and the organic matter in the sediment.
Irrigation waters and pipe-based biofilms as sources for antibiotic-resistant bacteria.
Blaustein, Ryan A; Shelton, Daniel R; Van Kessel, Jo Ann S; Karns, Jeffrey S; Stocker, Matthew D; Pachepsky, Yakov A
2016-01-01
The presence of antibiotic-resistant bacteria in environmental surface waters has gained recent attention. Wastewater and drinking water distribution systems are known to disseminate antibiotic-resistant bacteria, with the biofilms that form on the inner-surfaces of the pipeline as a hot spot for proliferation and gene exchange. Pipe-based irrigation systems that utilize surface waters may contribute to the dissemination of antibiotic-resistant bacteria in a similar manner. We conducted irrigation events at a perennial stream on a weekly basis for 1 month, and the concentrations of total heterotrophic bacteria, total coliforms, and fecal coliforms, as well as the concentrations of these bacterial groups that were resistant to ampicillin and tetracycline, were monitored at the intake water. Prior to each of the latter three events, residual pipe water was sampled and 6-in. sections of pipeline (coupons) were detached from the system, and biofilm from the inner-wall was removed and analyzed for total protein content and the above bacteria. Isolates of biofilm-associated bacteria were screened for resistance to a panel of seven antibiotics, representing five antibiotic classes. All of the monitored bacteria grew substantially in the residual water between irrigation events, and the biomass of the biofilm steadily increased from week to week. The percentages of biofilm-associated isolates that were resistant to antibiotics on the panel sometimes increased between events. Multiple-drug resistance was observed for all bacterial groups, most often for fecal coliforms, and the distributions of the numbers of antibiotics that the total coliforms and fecal coliforms were resistant to were subject to change from week to week. Results from this study highlight irrigation waters as a potential source for antibiotic-resistant bacteria, which can subsequently become incorporated into and proliferate within irrigation pipe-based biofilms.
Pathogen transport and fate modeling in the Upper Salem River Watershed using SWAT model.
Niazi, Mehran; Obropta, Christopher; Miskewitz, Robert
2015-03-15
Simulation of the fate and transport of pathogen contamination was conducted with SWAT for the Upper Salem River Watershed, located in Salem County, New Jersey. This watershed is 37 km(2) and land uses are predominantly agricultural. The watershed drains to a 32 km stretch of the Salem River upstream of the head of tide. This strech is identified on the 303(d) list as impaired for pathogens. The overall goal of this research was to use SWAT as a tool to help to better understand how two pathogen indicators (Escherichia coli and fecal coliform) are transported throughout the watershed, by determining the model parameters that control the fate and transport of these two indicator species. This effort was the first watershed modeling attempt with SWAT to successfully simulate E. coli and fecal coliform simultaneously. Sensitivity analysis has been performed for flow as well as fecal coliform and E. coli. Hydrologic calibration at six sampling locations indicate that the model provides a "good" prediction of watershed outlet flow (E = 0.69) while at certain upstream calibration locations predictions are less representative (0.32 < E < 0.70). Monthly calibration and validation of the pathogen transport and fate model was conducted for both fecal coliform (0.07 < E < 0.47 and -0.94 < E < 0.33) and E. coli (0.03 < E < 0.39 and -0.81 < E < 0.31) for the six sampling points. The fit of the model compared favorably with many similar pathogen modeling efforts. The research contributes new knowledge in E. coli and fecal coliform modeling and will help increase the understanding of sensitivity analysis and pathogen modeling with SWAT at the watershed scale. Copyright © 2014 Elsevier Ltd. All rights reserved.
Inactivation of particle-associated coliforms by chlorine and monochloramine.
Berman, D; Rice, E W; Hoff, J C
1988-01-01
Sieves and nylon screens were used to separate primary sewage effluent solids into particle fractions of less than 7- or greater than 7-micron size. The efficiency of separation was determined by using a particle counter. Indigenous coliforms associated with the particle fractions were tested for their resistance to chlorine and monochloramine. Coliforms associated with the less than 7-microns fraction were inactivated more rapidly by 0.5 mg of chlorine per liter at 5 degrees C and pH 7 than coliforms associated with the greater than 7-microns fraction. Homogenization of the greater than 7-microns fraction not only resulted in an increase in the number of less than 7-microns particles, but also increased the rate of inactivation to a rate similar to that of the less than 7-microns fraction. With 1 mg of monochloramine per liter at 5 degrees C and pH 7, particle size had no appreciable effect on the rate of inactivation. At pH 8, however, the less than 7-micron fraction was inactivated more rapidly than the greater than 7-micron fraction. The time required for 99% inactivation of the particle fractions with monochloramine at pH 7 or 8 was 20- to 50-fold greater than the time required for the same amount of inactivation with chlorine at pH 7. The results indicate that coliforms associated with sewage effluent particles are inactivated more rapidly with 0.5 mg of chlorine per liter than with 1.0 mg of monochloramine per liter. However, greater than 7-micron particles can have a protective effect against the disinfecting action of chlorine. PMID:3355136
Demcheck, Dennis K.
1996-01-01
Physical and chemical-related properties, concentrations of chemical constituents, which included major ions and nutrients, and concentrations of fecal-coliform bacteria were determined for 17 sites on 11 streams in St. Tammany Parish, Louisiana, during the period April-August 1995. The streams were sampled to assess the effects of different streamflow conditions on the concentrations of water-quality constituents. The streams included in the study were Tchefuncte River, Bogue Falaya, Abita River, Bayou Chinchouba, Bayou Castine, Cane Bayou, Bayou Lacombe, Bayou Liberty, Bayou Bonfouca, Bogue Chitto, and West Pearl River. Water-quality samples were collected under several hydrologic conditions. These conditions included a period of wet weather and sustained high river stages; a period of local storms several days apart and river stages typical of that situation; and a period of dry weather and low river stages. The concentrations of inorganic chemical constituents in water from the upstream sites generally were low. Concentrations from the downstream sites varied and were higher. Nutrient and fecal-coliform bacteria concentrations varied and indicated that degraded water-quality conditions that typically occur during storms persisted less than 1-3 days. In general, the larger the drainage basin, the longer it takes for the stream to recover. Fecal-coliform concen- trations reflected the effects of small, isolated storms in the area. Bayou Castine, sampled immediately after a storm, had a fecal-coliform concentration of 26,000 colonies per 100 milliliters. The stream was resampled 24 hours later, and the fecal-coliform concentration had decreased to 1,700 colonies per 100 milliliters. This is an indication of the rapid water-quality changes that typically occur in small streams.
Nasser, Abidelfatah M; Benisti, Neta-Lee; Ofer, Naomi; Hovers, Sivan; Nitzan, Yeshayahu
2017-01-28
Advanced wastewater treatment processes are applied to prevent the environmental dissemination of pathogenic microorganisms. Giardia lamblia causes a severe disease called giardiasis, and is highly prevalent in untreated wastewater worldwide. Monitoring the microbial quality of wastewater effluents is usually based on testing for the levels of indicator microorganisms in the effluents. This study was conducted to compare the suitability of fecal coliforms, F+ coliphages and sulfide reducing clostridia (SRC) as indicators for the reduction of Giardia cysts in two full-scale wastewater treatment plants. The treatment process consists of activated sludge, coagulation, high rate filtration and either chlorine or UV disinfection. The results of the study demonstrated that Giardia cysts are highly prevalent in raw wastewater at an average concentration of 3600 cysts/L. Fecal coliforms, F+ coliphages and SRC were also detected at high concentrations in raw wastewater. Giardia cysts were efficiently removed (3.6 log 10 ) by the treatment train. The greatest reduction was observed for fecal coliforms (9.6 log 10 ) whereas the least reduction was observed for F+ coliphages (2.1 log 10 ) following chlorine disinfection. Similar reduction was observed for SRC by filtration and disinfection by either UV (3.6 log 10 ) or chlorine (3.3 log 10 ). Since F+ coliphage and SRC were found to be more resistant than fecal coliforms for the tertiary treatment processes, they may prove to be more suitable as indicators for Giardia. The results of this study demonstrated that advanced wastewater treatment may prove efficient for the removal of Giardia cysts and may prevent its transmission when treated effluents are applied for crop irrigation or streams restoration.
NASA Astrophysics Data System (ADS)
Tekpor, M.; Akrong, M. O.; Asmah, M. H.; Banu, R. A.; Ansa, E. D. O.
2017-09-01
The study was carried out to determine the bacteriological safety of water in hand-dug wells in the Atebubu-Amantin District of the Brong-Ahafo Region in Ghana. A total of 60 samples were collected from ten hand dug wells and analysed for total coliform (TC), faecal coliform (FC), E. coli (EC), Salmonella spp. (SP) and Enterococcus spp. (ES). Data was collected in both the rainy and the dry seasons. The results obtained showed that water from all the wells in the study area did not meet the World Health Organisation guideline and Ghana standard for drinking water of zero (0) coliform forming unit (cfu) per 100 ml for TC, FC, EC, SP and ES, respectively. Contamination was found to be high in the wells during the wet season as compared to the dry season. Wells (A1 to A5) which were close to septic tanks had high bacteria counts in both seasons. The total coliform counts ranged from 2.98 to 5.93 log cfu/100 ml in the wet season and 3.10-5.03 log cfu/100 ml in the dry season. There was drastic reduction of faecal coliform count from a range of 2.78-4.55 log cfu/100 ml in the wet season to 1.70-3.51 log cfu/100 ml in the dry season. The high bacteria count in wells A1 to A5 could be attributed to the closeness of the wells to the septic tank, and contaminant transport through the saturated underground zones. It is recommended that the water should be treated properly before drinking.
Şengül, Mustafa; Erkaya, Tuba; Aksakal, Vecihi
2017-01-01
The aim of this study was to investigate the effects of production systems and milk collection periods on the somatic cell count (SCC), some microbiological properties, total aerobic mesophilic bacteria (TAMB), coliform, Staphylococcus aureus (S. aureus), yeast and mould) and antibiotic residue of milk; in Turkey. Milk samples were collected from 9 conventional farms and 9 organic farms during one year time, at six different months (December 2013 to October 2014), and all farms were selected from the same geographical locations. All organically managed farms had organic production certificates given by the Republic of Turkey Ministry of Food, Agriculture and Livestock. The count of TAMB, coliform, and coagulase positive S. aureus were affected by production systems at the level of p<0.01; yeast and mold, and somatic cell count (SCC) were affected at the level of p<0.05. But, differences according to months were statistically significant only on TAMB (p<0.01) and coliform (p<0.05) counts. The general means of TAMB, coliform and yeast and mould counts of the organic milk (OM) were significantly lower (p<0.05), while the general means of SCC and coagulase positive S. aureus count of the OM was significantly higher (p<0.05) compared to conventional milk (CM). Antibiotic residue was determined in one of the CM sample and in two of the OM samples. Our study is the first research that compared conventional and organic milk in Turkey. This study indicated that the microbiological quality of OM was the higher in terms of TAMB, coliform and yeast and mould, whereas was the lower in relation to SCC and coagulase positive S. aureus counts. But, the quality of both milk types should be improved. PMID:28515650
Koczura, R; Krysiak, N; Taraszewska, A; Mokracka, J
2015-08-01
To characterize the integron-harbouring Gram-negative bacteria in recreational lakes, with focus on the genetic content of integrons, antimicrobial resistance profiles and virulence-associated genes. The presence and structure of integrons in coliform bacteria isolated from the water of four recreational lakes located in Poznań, Poland, was determined by PCR method. Antimicrobial resistance testing was done by disc diffusion method. Virulence-associated genes in integron-bearing Escherichia coli isolates were detected by PCR. A total of 155 integron-bearing strains of coliform bacteria were cultured. Sequence analysis showed the presence of dfrA7, aadA1, dfrA1-aadA1, dfrA17-aadA5 and dfrA12-orfF-aadA2 gene cassette arrays in class 1 integrons and dfrA1-sat2-aadA1 in class 2 integrons. Higher frequency of integron-positive bacteria and higher antimicrobial resistance ranges were noted in colder months (January and November) compared with spring and summer months. The integron-harbouring E. coli carried up to nine virulence-associated genes, with the highest frequency of kpsMT (84.6%) and traT (783%), coding for group 2 capsule and determining human serum resistance respectively. Integron-bearing multidrug resistant coliform bacteria carrying virulence genes are present in waters of recreational lakes. This study presents antimicrobial resistance and virulence-associated genes in integron-bearing coliform bacteria present in the waters of recreational lakes, which showed that multidrug resistant bacteria with virulence traits might pose a threat to public health. Moreover, the presence of genes typical for enterotoxigenic and Shiga toxin-producing E. coli is a concern. © 2015 The Society for Applied Microbiology.
Karra, Styliani; Katsivela, Eleftheria
2007-03-01
Measurements were conducted at a Mediterranean site (latitude 35 degrees 31' north and longitude 24 degrees 03' east) during summer, to study the concentration of microorganisms emitted from a wastewater treatment plant under intensive solar radiation (520-840 W/m2) and at elevated air temperatures (25-31 degrees C). Air samples were taken with the Air Sampler MAS 100 (Merck) at each stage of an activated-sludge wastewater treatment (pretreatment, primary settling tanks, aeration tanks, secondary settling tanks, chlorination, and sludge processors). Cultivation methods based on the viable counts of mesophilic heterotrophic bacteria, as well as of indicator microorganisms of faecal contamination (total and faecal coliforms and enterococci), and fungi were performed. During air sampling, temperature, solar radiation, relative humidity and wind speed were measured. The highest concentrations of airborne microorganisms were observed at the aerated grit removal of wastewater at the pretreatment stage. A gradual decrease of bioaerosol emissions was observed during the advanced wastewater treatment from the pretreatment to the primary, secondary and tertiary treatment (97.4% decrease of mesophilic heterotrophic bacteria, and 100% decrease of total coliforms, faecal coliforms and enterococci), 95.8% decrease of fungi. The concentration of the airborne microorganisms at the secondary and tertiary treatment of the wastewater was lower than in the outdoor control. At the same time, the reduction of the microbial load at the waste sludge processors was 19.7% for the mesophilic heterotrophic bacteria, 99.4% for the total coliforms, and 100% for the faecal coliforms and the enterococci, 84.2% for the fungi. The current study concludes that the intensive solar radiation, together with high ambient temperatures, as well as optimal wastewater treatment are the most important factors for low numbers of microbes in the air.
Tandon, Puja; Chhibber, Sanjay; Reed, Robert H
2005-07-01
The detection and enumeration of indicator bacteria such as Escherichia coli is used to assess the extent of faecal contamination of drinking water. On the basis of this approach, the effectiveness of storing water contaminated with faecal indicator bacteria in brass or earthern vessels (mutkas) of the type used in rural India have been investigated. Suspensions of bacteria in sterile distilled water were maintained for up to 48 h in each vessel and enumerated by surface plate counts on nutrient agar (non-selective) and several selective coliform media at 37 degrees C either under standard aerobic conditions, or under conditions designed to neutralise reactive oxygen species (ROS), e.g. using an anaerobic cabinet to prepare plates of pre-reduced growth medium or by inclusion of sodium pyruvate in the growth medium, with incubation of aerobically-prepared plates in an anaerobic jar. The counts obtained for E. coli decreased on short-term storage in a brass mutka; counts for selective media were lower than for equivalent counts for non-selective medium, with ROS-neutralised conditions giving consistently higher counts than aerobic incubation. However, after 48 h, no bacteria were cultivable under any conditions. Similar results were obtained using water from environmental sources in the Panjab, and from rural households where brass and earthern mutkas are used for storage of drinking water, with enumeration on selective coliform media (presumptive total coliforms). In all cases results indicated that, while storage of water in a brass mutka can inactivate E. coli and coliforms over a 48 h period, standard aerobic plate counting using selective media may not be fully effective in enumerating sub-lethally damaged bacteria.
Tantawiwat, Suwalee; Tansuphasiri, Unchalee; Wongwit, Waranya; Wongchotigul, Varee; Kitayaporn, Dwip
2005-01-01
Multiplex PCR amplification of lacZ, uidA and plc genes was developed for the simultaneous detection of total coliform bacteria for Escherichia coli and Clostridium perfringens, in drinking water. Detection by agarose gel electrophoresis yielded a band of 876 bp for the lacZ gene of all coliform bacteria; a band of 147 bp for the uidA gene and a band of 876 bp for the lacZ gene of all strains of E. coli; a band of 280 bp for the p/c gene for all strains of C. perfringens; and a negative result for all three genes when tested with other bacteria. The detection limit was 100 pg for E. coli and C. perfringens, and 1 ng for coliform bacteria when measured with purified DNA. This assay was applied to the detection of these bacteria in spiked water samples. Spiked water samples with 0-1,000 CFU/ml of coliform bacteria and/or E. coli and/or C. perfringens were detected by this multiplex PCR after a pre-enrichment step to increase the sensitivity and to ensure that the detection was based on the presence of cultivable bacteria. The result of bacterial detection from the multiplex PCR was comparable with that of a standard plate count on selective medium (p=0.62). When using standard plate counts as a gold standard, the sensitivity for this test was 99.1% (95% CI 95.33, 99.98) and the specificity was 90.9 % (95% CI 75.67, 98.08). Multiplex PCR amplification with a pre-enrichment step was shown to be an effective, sensitive and rapid method for the simultaneous detection of these three microbiological parameters in drinking water.
Beverages: bottled water. Final rule.
2009-05-29
The Food and Drug Administration (FDA) is amending its bottled water regulations to require that bottled water manufacturers test source water for total coliform, as is required for finished bottled water products, and to require, if any coliform organisms are detected in source water, that bottled water manufacturers determine whether any of the coliform organisms are Escherichia coli (E. coli), an indicator of fecal contamination. FDA also is amending its bottled water regulations to require, if any coliform organisms are detected in finished bottled water products, that bottled water manufacturers determine whether any of the coliform organisms are E. coli. FDA also is amending the adulteration provision of the bottled water standard to reflect the possibility of adulteration caused by the presence of filth. Bottled water containing E. coli will be considered adulterated, and source water containing E. coli will not be considered to be of a safe, sanitary quality and will be prohibited from use in the production of bottled water. FDA is also amending its bottled water regulations to require that, before a bottler can use source water from a source that has tested positive for E. coli, the bottler must take appropriate measures to rectify or eliminate the cause of E. coli contamination of that source, and that the bottler must keep records of such actions. Existing regulatory provisions require bottled water manufacturers to keep records of new testing required by this rule. This final rule will ensure that FDA's standards for the minimum quality of bottled water, as affected by fecal contamination, will be no less protective of the public health than those set by the Environmental Protection Agency (EPA) for public drinking water.
Alfaro, M.; Salazar, F.; Troncoso, E.; Mitchell, R. M.; Ramirez, L.; Naguil, A.; Zamorano, P.; Collins, M. T.
2013-01-01
The study assessed the effect of soil slope on Mycobacterium avium subsp. paratuberculosis transport into rainwater runoff from agricultural soil after application of M. avium subsp. paratuberculosis-contaminated slurry. Under field conditions, 24 plots of undisturbed loamy soil 1 by 2 m2 were placed on platforms. Twelve plots were used for water runoff: 6 plots at a 3% slope and 6 plots at a 15% slope. Half of the plots of each slope were treated with M. avium subsp. paratuberculosis-contaminated slurry, and half were not treated. Using the same experimental design, 12 plots were established for soil sampling on a monthly basis using the same spiked slurry application and soil slopes. Runoff following natural rainfall was collected and analyzed for M. avium subsp. paratuberculosis, coliforms, and turbidity. M. avium subsp. paratuberculosis was detected in runoff from all plots treated with contaminated slurry and one control plot. A higher slope (15%) increased the likelihood of M. avium subsp. paratuberculosis detection but did not affect the likelihood of finding coliforms. Daily rainfall increased the likelihood that runoff would have coliforms and the coliform concentration, but it decreased the M. avium subsp. paratuberculosis concentration in the runoff. When there was no runoff, rain was associated with increased M. avium subsp. paratuberculosis concentrations. Coliform counts in runoff were related to runoff turbidity. M. avium subsp. paratuberculosis presence/absence, however, was related to turbidity. Study duration decreased bacterial detection and concentration. These findings demonstrate the high likelihood that M. avium subsp. paratuberculosis in slurry spread on pastures will contaminate water runoff, particularly during seasons with high rainfall. M. avium subsp. paratuberculosis contamination of water has potential consequences for both animal and human health. PMID:23542616
Land cover impacts on stream nutrients and fecal coliform in the lower Piedmont of West Georgia
NASA Astrophysics Data System (ADS)
Schoonover, Jon E.; Lockaby, B. Graeme
2006-12-01
SummaryAs urbanization infiltrates into rural areas, stream water quality is expected to decline as a result from increased impervious surface and greater sources for pollutants. Consequently, West Georgia's water quality is threatened by extensive development as well as other land uses such as livestock grazing and silvicultural activity. Maintenance of stream water quality, as land development occurs, is critical for the protection of drinking water and biotic integrity. A 2-phase, watershed-scale study was established to develop relationships among land cover and water quality within western Georgia. During phase 1, nutrient and fecal coliform data were collected within 18 mixed land use watersheds, ranging in size from 500 to 2500 ha. Regression models were developed that related land cover to stream water nutrient and fecal coliform concentrations. Nutrient and fecal coliform concentrations within watersheds having >24% impervious surface (IS) were often higher than those in nonurban watersheds (i.e., <5% IS) during both base flow (N: 1.64 mg/L versus 0.61 mg/L, and FC: 430 versus 120 MPN/100 ml) and storm flow (N: 1.93 mg/L versus 0.36 mg/L, and FC: 1600 versus 167 MPN/100 ml). Fecal coliform bacteria in urbanized areas consistently exceeded the US EPA's review criterion for recreational waters during both base flow and to a greater extent storm flow. During phase 2, regression models were tested based on data from six newly chosen watersheds with similar land use/cover patterns. Lastly, theoretical watersheds, based on land use percentages, were created to illustrate trends in water quality impairment as land development occurs. The models developed from this research could be used to forecast water quality changes under various land use scenarios in the developing Piedmont region of the US.
Ibe, Nnenne I.; Iroegbu, Christian U.
2011-01-01
Bacterial count in prepared food or water is a key factor in assessing the quality and safety of food. It also reveals the level of hygiene adopted by food handlers in the course of preparation of such foods. This comparative study evaluated the bacteriological quality of food and water consumed in Nsukka, Enugu state, Nigeria, using three bacteria enumeration methods. Data obtained are assumed to reflect the level of personal and environmental hygiene in the study population. Ten types of foods—beans, yam, abacha, okpa, moimoi, pear, cassava foofoo, rice, agidi, and garri—and 10 water samples were evaluated for bacteriological quality, precisely determining the level of coliform contamination, using the most probable number (MPN), lactose fermentation count (LFC), and Escherichia coli count (ECC) methods. Bacterial counts differed significantly (p<0.05) among the various food samples. However, this did not differ significantly in the three methods used for the enumeration of coliforms, suggesting that any of the three methods could be validly used for such studies with confidence. Escherichia coli and Klebsiella pneumoniae were the two major coliforms identified among 98 coliform isolates obtained from the various food samples, of which 78 (79.6%) were assumed to be of human origin on account of their ability to grow at 44 °C. The level of coliform contamination in the food samples from vendors and restaurants (geometric mean count 7.64-9.21; MPN ≥50) were above the accepted 104 colony-forming unit/g or MPN ≤10 limits. The results of the study, therefore, call for stringent supervision and implementation of food-safety practices and regular education on food and personal hygiene among food vendors. PMID:22283029
Quality assessment of commercially supplied drinking jar water in Chittagong City, Bangladesh
NASA Astrophysics Data System (ADS)
Mina, Sohana Akter; Marzan, Lolo Wal; Sultana, Tasrin; Akter, Yasmin
2018-03-01
Chittagong is the second most populated city in Bangladesh where drinking water is supplied using small jar. Water quality is an important concern for the consumers and, therefore, the present study was done by collecting 38 drinking jar water samples from Chittagong City, Bangladesh to determine the microbial contamination and physiochemical properties. Molecular study was done by the PCR amplification of 16SrDNA, LacZ and uidA gene for the identification of bacteria, coliform and fecal coliform. TVC, MPN and different biochemical test were done for enumeration and identification. TDS, pH, and metals (Fe, As, Pb and Cr) concentration were also measured. No heavy metal (As, Pb and Cr) was found in any of the water samples but Fe was detected in low concentrations (0.02-0.05 mg/l). TDS and pH level were normal in all samples. But microbial contaminations were (60.53 and 50%) recorded in molecular and biochemical test, respectively. The range of total bacterial count was (1.5 × 102-1.6 × 104) cfu/ml. The total coliform count (TCCm) was recorded (14-40) in 100 ml of water samples. The presence of total coliform and fecal coliform was 26.32 and 18.42%, respectively, in PCR analysis but in biochemical test those were 18.42 and 15.78%, respectively. A total of 11 bacterial species: Enterobacter aerogenes, Escherrichia coli, Aeromonas, Bacillus sp., Cardiobacterium, Corynebacterium, Clostridium, Klebsiella sp., Lactobacillus, Micrococcus sp., Pseudomonas sp. were found. This study indicates that some of the drinking jar water samples were of poor quality which may increase the risk of water-borne disease. Hence, the producer of drinking jar water has to implement necessary quality control steps.
Ribeiro, E B; Bastos, L S; Galeno, L S; Mendes, R S; Garino, F; Carvalho-Neta, R N F; Costa, F N
2016-12-15
This study was conducted to evaluate the use of biochemical biomarkers and microbiological analysis to identify levels of oyster contamination at different ports in São Luís Island (Maranhão), Brazil. Oysters were analyzed for total coliforms, thermotolerant coliforms, Escherichia coli and Aeromonas spp. In addition, tissue was removed from the digestive gland to determine the glutathione-S-transferase (GST) and catalase (CAT) activity. The highest percentage of microbiological contamination of oyster samples occurred during the rainy season. The activity of GST and catalase in oysters was also higher in the rainy season, coinciding with the greatest abundance of total and thermotolerant coliforms. Among the prospective biomarkers, GST showed the best results for identification of areas with higher levels of contamination. Copyright © 2016 Elsevier Ltd. All rights reserved.
Short communication: jenny milk as an inhibitor of late blowing in cheese: a preliminary report.
Cosentino, C; Paolino, R; Freschi, P; Calluso, A M
2013-06-01
Late blowing on semihard and hard cheese may have an important economic effect on dairy production. Many studies have attempted to prevent this defect by physical treatment, the use of additives, and the use of bacteriocins. In this paper, we look at the effect of jenny milk as an inhibitor of blowing caused by clostridia and coliforms in ewe cheese making. Bulk ewe and jenny milk samples were collected in the morning by mechanical milking and were refrigerated at 4°C. On the collected samples, the count of somatic cells, coliforms, Clostridium butyricum, and Escherichia coli were determined. The bulk raw milk was divided in two 45-L vats: vat 1 was used as a control, whereas 0.5L of jenny milk was added to vat 2. Four semihard cheeses, weighing about 2 kg each, were made from each vat. Cheese making was replicated twice. After a ripening period of 60 d, the count of coliforms and of C. butyricum was determined. In the treated group, a significant inhibition of coliform bacteria was observed. The addition of jenny milk in cheese making may prove to be a useful and innovative approach for the inhibition of spore-forming clostridia strains. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Seasonal Microbial Conditions of Locally Made Yoghurt (Shalom) Marketed in Some Regions of Cameroon
Moh, Lamye Glory; Keilah, Lunga Paul; Etienne, Pamo Tedonkeng
2017-01-01
The microbial conditions of locally made yoghurt (shalom) marketed in three areas of Cameroon were evaluated during the dry and rainy seasons alongside three commercial brands. A total of ninety-six samples were collected and the microbial conditions were based on total aerobic bacteria (TEB), coliforms, yeasts, and moulds counts as well as the identification of coliforms and yeasts using identification kits. Generally, there was a significant increase (p ≤ 0.05) in total aerobic and coliform counts (especially samples from Bamenda), but a decrease in yeast and mould counts of the same samples during the rainy season when compared to those obtained during the dry season. These counts were mostly greater than the recommended standards. Twenty-one Enterobacteriaceae species belonging to 15 genera were identified from 72 bacterial isolates previously considered as all coliforms. Pantoea sp. (27.77%) was highly represented, found in 41% (dry season) and 50% (rainy season) of samples. In addition, sixteen yeast species belonging to 8 genera were equally identified from 55 yeast isolates and Candida sp. (76.36%) was the most represented. This result suggests that unhygienic practices during production, ignorance, warmer weather, duration of selling, and inadequate refrigeration are the principal causes of higher levels of contamination and unsafe yoghurts. PMID:29423400
Elimination of coliforms and Salmonella spp. in sheep meat by gamma irradiation treatment
Henriques, Luciana Salles Vasconcelos; da Costa Henry, Fábio; Barbosa, João Batista; Ladeira, Silvania Alves; de Faria Pereira, Silvia Menezes; da Silva Antonio, Isabela Maria; Teixeira, Gina Nunes; Martins, Meire Lelis Leal; de Carvalho Vital, Helio; dos Prazeres Rodrigues, Dália; dos Reis, Eliane Moura Falavina
2013-01-01
This study aimed at evaluating the bacteriological effects of the treatment of sheep meat contaminated with total coliforms, coliforms at 45 °C and Salmonella spp. by using irradiation at doses of 3 kGy and 5 kGy. Thirty sheep meat samples were collected from animals located in Rio de Janeiro State, Brazil, and then grouped in three lots including 10 samples: non-irradiated (control); irradiated with 3 kGy; and irradiated with 5 kGy. Exposure to gamma radiation in a 137Cs source-driven irradiating facility was perfomed at the Nuclear Defense Section of the Brazilian Army Technological Center (CTEx) in Rio de Janeiro. The samples were kept under freezing temperature (−18 °C) until the analyses, which occurred in two and four months after irradiation. The results were interpreted by comparison with the standards of the current legislation and demonstrated that non-irradiated samples were outside the parameters established by law for all groups of bacteria studied. Gamma irradiation was effective in inactivating those microorganisms at both doses tested and the optimal dose was achieved at 3 kGy. The results have shown not only the need for sanitary conditions improvements in slaughter and processing of sheep meat but also the irradiation effectiveness to eliminate coliform bacteria and Salmonella spp. PMID:24688504
Zacarias Sylvestre, Silvia Helena; Lux Hoppe, Estevam Guilherme; de Oliveira, Roberto Alves
2014-01-01
The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 105 and 109 MPN (100 mL)−1, while helminth eggs ranged from 0.86 to 9.27 eggs g−1 TS. PMID:24812560
Evaluation of future base-flow water-quality conditions in the Hillsborough River, Florida
Fernandez, Mario; Goetz, C.L.; Miller, J.E.
1984-01-01
A one-dimensional, steady-state, water-quality model was developed for a 30.0 mile reach of the Hillsborough River to evaluate water-quality conditions to be expected from future development. The model was calibrated and verified using data collected under critical base-flow conditions in April and December 1978. Dissolved organic nitrogen, nitrate nitrogen, and total and fecal coliforms were modeled for most of the study reach. Model results were used to evaluate the impacts of two typical housing developments on water-quality conditions in Tampa Reservoir. One development is located in the Cypress Creek basin and the other near the upper end of the study reach. Model results show development in the Hillsborough River basin may cause increased total and fecal coliform conditions. Simulated total coliforms at the Tampa water treatment plant for 1-, 3-, and 5-square-mile developments located in the Cypress Creek basin were 3,000, 5,400, and 8,300 colonies per 100 milliliters. Similar developments, however, located near the upper end of the study reach were 2,000, 3,600, and 5,100 colonies per 100 milliliters. Simulated fecal coliforms were 360, 700, and 100 and 180, 350, and 510 colonies per 100 milliliters, respectively. Other constituents modeled showed only minor increases in concentrations. (USGS)
Hua, Ang Kean
2017-01-01
Malacca River water quality is affected due to rapid urbanization development. The present study applied LULC changes towards water quality detection in Malacca River. The method uses LULC, PCA, CCA, HCA, NHCA, and ANOVA. PCA confirmed DS, EC, salinity, turbidity, TSS, DO, BOD, COD, As, Hg, Zn, Fe, E. coli , and total coliform. CCA confirmed 14 variables into two variates; first variate involves residential and industrial activities; and second variate involves agriculture, sewage treatment plant, and animal husbandry. HCA and NHCA emphasize that cluster 1 occurs in urban area with Hg, Fe, total coliform, and DO pollution; cluster 3 occurs in suburban area with salinity, EC, and DS; and cluster 2 occurs in rural area with salinity and EC. ANOVA between LULC and water quality data indicates that built-up area significantly polluted the water quality through E. coli , total coliform, EC, BOD, COD, TSS, Hg, Zn, and Fe, while agriculture activities cause EC, TSS, salinity, E. coli , total coliform, arsenic, and iron pollution; and open space causes contamination of turbidity, salinity, EC, and TSS. Research finding provided useful information in identifying pollution sources and understanding LULC with river water quality as references to policy maker for proper management of Land Use area.
Grabow, W O; du Preez, M
1979-01-01
Total coliform counts obtained by means of standard membrane filtration techniques, using MacConkey agar, m-Endo LES agar, Teepol agar, and pads saturated with Teepol broth as growth media, were compared. Various combinations of these media were used in tests on 490 samples of river water and city wastewater after different stages of conventional purification and reclamation processes including lime treatment, and filtration, active carbon treatment, ozonation, and chlorination. Endo agar yielded the highest average counts for all these samples. Teepol agar generally had higher counts then Teepol broth, whereas MacConkey agar had the lowest average counts. Identification of 871 positive isolates showed that Aeromonas hydrophila was the species most commonly detected. Species of Escherichia, Citrobacter, Klebsiella, and Enterobacter represented 55% of isolates which conformed to the definition of total coliforms on Endo agar, 54% on Teepol agar, and 45% on MacConkey agar. Selection for species on the media differed considerably. Evaluation of these data and literature on alternative tests, including most probable number methods, indicated that the technique of choice for routine analysis of total coliform bacteria in drinking water is membrane filtration using m-Endo LES agar as growth medium without enrichment procedures or a cytochrome oxidase restriction. PMID:394678
Hügler, Michael; Böckle, Karin; Eberhagen, Ingrid; Thelen, Karin; Beimfohr, Claudia; Hambsch, Beate
2011-01-01
Monitoring of microbiological contaminants in water supplies requires fast and sensitive methods for the specific detection of indicator organisms or pathogens. We developed a protocol for the simultaneous detection of E. coli and coliform bacteria based on the Fluorescence in situ Hybridization (FISH) technology. This protocol consists of two approaches. The first allows the direct detection of single E. coli and coliform bacterial cells on the filter membranes. The second approach includes incubation of the filter membranes on a nutrient agar plate and subsequent detection of the grown micro-colonies. Both approaches were validated using drinking water samples spiked with pure cultures and naturally contaminated water samples. The effects of heat, chlorine and UV disinfection were also investigated. The micro-colony approach yielded very good results for all samples and conditions tested, and thus can be thoroughly recommended for usage as an alternative method to detect E. coli and coliform bacteria in water samples. However, during this study, some limitations became visible for the single cell approach. The method cannot be applied for water samples which have been disinfected by UV irradiation. In addition, our results indicated that green fluorescent dyes are not suitable to be used with chlorine disinfected samples.
Limnological Monitoring on the Upper Mississippi River System, 1993-1996: Lake City Field Station
1999-10-01
Reports of this type provide a synopsis of the collected data and collection methods, as well as a preliminary report of remarkable or unusual conditions ... conditions . To meet this need, Congress authorized a Long Term Resource Monitoring Program (LTRMP) for the Upper Mississippi River System (UMRS). The LTRMP...primarily for human consumption or regulatory purposes (e.g., chemical oxygen demand, biochemical oxygen demand, total coliform bacteria , fecal coliform
Toys are a potential source of cross-infection in general practitioners' waiting rooms.
Merriman, Eileen; Corwin, Paul; Ikram, Rosemary
2002-01-01
The waiting rooms of general practitioners' surgeries usually have toys provided for children. The level of contamination of these toys and the effectiveness of toy decontamination was investigated in this study. Hard toys from general practitioners' waiting rooms had relatively low levels of contamination, with only 13.5% of toys showing any coliform counts. There were no hard toys with heavy contamination by coliforms or other bacteria. Soft toys were far more likely to be contaminated, with 20% of toys showing moderate to heavy coliform contamination and 90% showing moderate to heavy bacterial contamination. Many waiting-room toys are not cleaned routinely. Soft toys are hard to disinfect and tend to rapidly become recontaminated after cleaning. Conversely, hard toys can be cleaned and disinfected easily. Soft toys in general practitioners' waiting rooms pose an infectious risk and it is therefore recommended that soft toys are unsuitable for doctors' waiting rooms. PMID:11885823
Data on microbiological quality assessment of rural drinking water supplies in Poldasht county.
Yousefi, Mahmood; Saleh, Hossein Najafi; Yaseri, Mehdi; Mahvi, Amir Hossein; Soleimani, Hamed; Saeedi, Zhyar; Zohdi, Sara; Mohammadi, Ali Akbar
2018-04-01
In this research, the villages with water supply systems under the supervision of the Water and Wastewater Company in Poldasht County, Iran in 2015 was studied. 648 samples were taken from 57 villages during 12month period to test for microbial quality according to the latest guidelines of WHO. Fecal coliform, coliform, turbidity, pH and free residual chlorine were analyzed. Also we used linear Regression statistical analysis for collected data. Result of Data showed that 13.6% of the villages under study had contaminated water resources. In 100 percent of the water sample resource the turbidity level was less than Iranian maximum permissible levels (5 NTU). There was a linear relation between the Free residual color and Coliform in different month of follow up ( r = -0.154, P < 0.001). Data suggests water resources should be comprehensively planned and monitored keeping in view the WHO recommended parameters.
UV disinfection pilot plant study at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huffines, R.L.; Beavers, B.A.
1993-05-01
An ultraviolet light disinfection system pilot plant was operated at the Savannah River Site Central Shops sanitary wastewater treatment package plant July 14, 1992 through August 13, 1992. The purpose was to determine the effectiveness of ultraviolet light disinfection on the effluent from the small package-type wastewater treatment plants currently used on-site. This pilot plant consisted of a rack of UV lights suspended in a stainless steel channel through which a sidestream of effluent from the treatment plant clarifier was pumped. Fecal coliform analyses were performed on the influent to and effluent from the pilot unit to verify the disinfectionmore » process. UV disinfection was highly effective in reducing fecal coliform colonies within NPDES permit limitations even under process upset conditions. The average fecal coliform reduction exceeded 99.7% using ultraviolet light disinfection under normal operating conditions at the package treatment plants.« less
Disinfection of low quality wastewaters by ultraviolet irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zukovs, G.; Kollar, J.; Monteith, H.D.
1986-03-01
Pilot-scale disinfection of simulated combined sewer overflow (CSO) by ultraviolet light (UV) and by high-rate chlorination were compared. Disinfection efficiency was evaluated over a range of dosages and contact times for fecal coliforms, enterococci, P. Aeruginosa, and Salmonella spp. Fecal coliform were reduced 3.0 to 3.2 logs at a UV dose of approximately 350,000..mu.. W s/cm/sup 2/. High-rate chlorination, at a contact time of 2.0 minutes and total residual chlorine concentration of approximately 25 mg/L (as Cl/sub 2/), reduced fecal coliforms by 4.0 logs. Pathogens were reduced to detection limits by both processes. Neither photoreactivation nor regrowth occurred int hemore » disinfected effluents. The estimated capital costs of CSO disinfection by UV irradiation were consistently higher than for chlorination/dechlorination; operation and maintenance costs were similar. 19 references.« less
UV disinfection pilot plant study at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huffines, R.L.; Beavers, B.A.
1993-01-01
An ultraviolet light disinfection system pilot plant was operated at the Savannah River Site Central Shops sanitary wastewater treatment package plant July 14, 1992 through August 13, 1992. The purpose was to determine the effectiveness of ultraviolet light disinfection on the effluent from the small package-type wastewater treatment plants currently used on-site. This pilot plant consisted of a rack of UV lights suspended in a stainless steel channel through which a sidestream of effluent from the treatment plant clarifier was pumped. Fecal coliform analyses were performed on the influent to and effluent from the pilot unit to verify the disinfectionmore » process. UV disinfection was highly effective in reducing fecal coliform colonies within NPDES permit limitations even under process upset conditions. The average fecal coliform reduction exceeded 99.7% using ultraviolet light disinfection under normal operating conditions at the package treatment plants.« less
Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R
1998-07-01
Cleaning treatments, such as high-pressure water wash at 35 degrees C or trim, alone and combined with sanitizing treatments, such as hot water (95 degrees C at the source), warm (55 degrees C) 2% lactic acid spray, and combinations of these two sanitizing methods, were compared for their effectiveness in reducing inoculated numbers (5.0 to 6.0 log CFU/cm2) of Salmonella typhimurium, Escherichia coli O157:H7, aerobic plate counts, Enterobacteriaceae, total coliforms, thermotolerant coliforms, and generic E. coli on hot beef carcass surface areas in a model carcass spray cabinet. Log reductions in numbers of all tested organisms by water wash or trim alone were significantly smaller than the log reductions obtained by the different combined treatments. Regardless of the cleaning treatment (water wash or trim) or surface area, the range for mean log reductions by hot water was from 4.0 to > 4.8 log CFU/cm2, by lactic acid spray was from 4.6 to > 4.9 log CFU/cm2, by hot water followed by lactic acid spray was from 4.5 to > 4.9 log CFU/cm2, and by lactic acid spray followed by hot water was from 4.4 to > 4.6 log CFU/cm2, for S. typhimurium and E. coli O157:H7. Identical reductions were obtained for thermotolerant coliforms and generic E. coli. No differences in bacterial reductions were observed for different carcass surface regions. Water wash and trim treatments caused spreading of the contamination to other areas of the carcass surface while providing an overall reduction in fecal or pathogenic contamination on carcass surface areas. This relocated contamination after either water wash or trim was most effectively reduced by following with hot water and then lactic acid spray. This combined treatment yielded 0% positive samples for S. typhimurium, E. coli O157:H7, thermotolerant coliforms, and generic E. coli on areas outside the inoculated areas, whereas percent positive samples after applying other combined treatments ranged from 22 to 44% for S. typhimurium, 0 to 44% for E. coli O157:H7, and 11 to 33% for both thermotolerant coliforms and generic E. coli. From data collected in this study, it is possible to choose an effective, inexpensive treatment to reduce bacterial contamination on beef carcasses. In addition, the similar reduction rates of total coliforms, thermotolerant coliforms, or generic E. coli may be useful in identifying an indicator to verify the effectiveness of the selected treatment as a critical control point in a Hazard Analysis and Critical Control Point program.
Biadglegne, Fantahun; Tessema, Belay; Kibret, Mulugeta; Abera, Bayeh; Huruy, Kahsay; Anagaw, Belay; Mulu, Andargachew
2009-10-01
The consumption of bottled drinking water is becoming increasing in Ethiopia. As a result there has been a growing concern about the chemical, physical and bacteriological quality of this product. Studies on the chemical, physical and bacteriological quality of bottled water is quite scarce in Ethiopia. This study was therefore aimed to assess the physicochemical and bacteriological qualities of three factories of bottled drinking water products produced in Amhara region. A Laboratory based comparative study was conducted to evaluate the physicochemical and bacteriological quality of three factories of bottled drinking water produced in Amhara region. Analysis on the quality of bottled drinking water from the sources, wholesalers and retailers were made with World Health Organization and Quality and Standards Authority of Ethiopia recommendations. Triplicate samples from three types of bottled drinking water were randomly collected and analyzed from June, 2006 to December, 2006. A total of 108 commercial bottled drinking water samples were analyzed. The result showed that except pH of factory A all the physicochemical parameters analyzed were with in the recommended limits. The pH value of factory A tested from sources is 5.3 and from wholesalers and retailers is 5.5 and 5.3, respectively, which is below the normal value set by World Health Organization (6.5-8.0) and Quality and Standards Authority of Ethiopia (6.0-8.5). Our analyses also demonstrated that 2 (16.7%) of the samples tested from sources and 1 (8.3%) from wholesalers of factory B were contaminated with total coliforms, where as 2 (16.7%) samples from retailers were also contaminated with total coliforms. On the other hand, 1 (8.3%) of the samples tested from wholesalers and 2 (16.7%) of the samples tested from retailers of factory A were also contaminated with total coliforms. Total coliforms were not detected from all samples of factory C, fecal coliforms were not also isolated from all samples. Percent of coefficient of variation showed that variations in total coliforms counts were significant with in the samples of both factory A and B (CV > 10%). Based on the recommended limit of World Health Organization and Quality and Standards Authority of Ethiopia, 7.4% of bottled drinking water sold commercially could be considered unfit for human consumption. Consumers of bottled water should be aware of this.
Hervert, C J; Alles, A S; Martin, N H; Boor, K J; Wiedmann, M
2016-09-01
It is estimated that 19% of the total food loss from retail, food service, and households comes from dairy products. A portion of this loss may be attributed to premature spoilage of products due to lapses in sanitation and postpasteurization contamination at the processing level. Bacterial groups including coliforms, Enterobacteriaceae (EB), and total gram-negative organisms represent indicators of poor sanitation or postpasteurization contamination in dairy products worldwide. Although Petrifilms (3M, St. Paul, MN) and traditional selective media are commonly used for the testing of these indicator organism groups throughout the US dairy industry, new rapid methods are also being developed. This project was designed to evaluate the ability of different methods to detect coliforms, EB, and other gram-negative organisms isolated from various dairy products and dairy processing environments. Using the Food Microbe Tracker database, a collection of 211 coliform, EB, and gram-negative bacterial isolates representing 25 genera associated with dairy products was assembled for this study. We tested the selected isolates in pure culture (at levels of approximately 15 to 300 cells/test) to evaluate the ability of 3M Coliform Petrifilm to detect coliforms, 3M Enterobacteriaceae Petrifilm, violet red bile glucose agar, and an alternative flow cytometry-based method (bioMérieux D-Count, Marcy-l'Étoile, France) to detect EB, and crystal violet tetrazolium agar to detect total gram-negative organisms. Of the 211 gram-negative isolates tested, 82% (174/211) had characteristic growth on crystal violet tetrazolium agar. Within this set of 211 gram-negative organisms, 175 isolates representing 19 EB genera were screened for detection using EB selective/differential testing methods. We observed positive results for 96% (168/175), 90% (158/175), and 86% (151/175) of EB isolates when tested on EB Petrifilm, violet red bile glucose agar, and D-Count, respectively; optimization of the cut-off thresholds for the D-Count may further improve its sensitivity and specificity, but will require additional data and may vary in food matrices. Additionally, 74% (129/175) of the EB isolates tested positive as coliforms. The data obtained from this study identify differences in detection between 5 microbial hygiene indicator tests and highlight the benefits of EB and total gram-negative testing methods. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Diak, James; Örmeci, Banu
2018-06-15
This study evaluated the ability of potassium ferrate(VI) and freeze-thaw to stabilise and dewater primary sludge. Potassium ferrate(VI) additions of 0.5 and 5.0 g/L were used as a pre-treatment prior to freeze-thaw. Samples were frozen at -10, -20 and -30 °C, and were kept frozen for 1, 8 and 15 days. The samples were subsequently thawed at room temperature in a setup which allowed meltwater to be separated from the sludge cake via gravity drainage. The meltwater was characterised in terms of fecal coliform, soluble chemical oxygen demand (COD), soluble proteins, soluble carbohydrates, pH and turbidity. The sludge cake was characterised in terms of fecal coliform, total solids (TS) and volatile solids (VS). Freeze-thaw with gravity meltwater drainage reduced the sludge volume by up to 79%. After being frozen for only 1 day, the concentrations of fecal coliform in many of the primary sludge samples were reduced to <1000 MPN/g dry solids (DS), representing >3-log inactivation in some cases. However, pre-treatment of the primary sludge with ≤5.0 g/L potassium ferrate(VI) resulted in significant increases in soluble proteins, soluble carbohydrates, and sCOD, and reduced the effectiveness of stand-alone freeze-thaw. Follow-up experiments using higher doses ranging from 5.1 to 24.9 g/L of potassium ferrate(VI) demonstrated that >5-log inactivation of fecal coliform in raw primary sludge can be achieved within 15 min using 15 g/L of potassium ferrate(VI), and the resulting concentration of fecal coliform in the sludge was 1023 MPN/g DS. Pre-treatment with 22.0 g/L of potassium ferrate(VI), followed by freeze-thaw, with only 3 days frozen, reduced the concentration of fecal coliform to below the detection limit in the meltwater and the sludge cake. This demonstrates that potassium ferrate(VI) and freeze-thaw offers the flexibility to adjust the ferrate(VI) dose to meet treatment requirements for land application, and can be used as a stand-alone sludge treatment technology for primary sludge that achieves both treatment and dewatering. Copyright © 2017 Elsevier Ltd. All rights reserved.
2002-11-01
synopsis of the collected data and collection methods, as well as a preliminary report of remarkable or unusual conditions in the system. They are intended...resource requires scientific understanding of the ecosystem and of its long-term trends and conditions . To meet this need, Congress authorized a Long...chemical oxygen demand, biochemical oxygen demand, total coliform bacteria , fecal coliform bacteria , fecal streptococcus, heavy metals, pesticides, and
Coliform Bacteria Monitoring in Fish Systems: Current Practices in Public Aquaria.
Culpepper, Erin E; Clayton, Leigh A; Hadfield, Catherine A; Arnold, Jill E; Bourbon, Holly M
2016-06-01
Public aquaria evaluate coliform indicator bacteria levels in fish systems, but the purpose of testing, testing methods, and management responses are not standardized, unlike with the coliform bacteria testing for marine mammal enclosures required by the U.S. Department of Agriculture. An online survey was sent to selected aquaria to document current testing and management practices in fish systems without marine mammals. The information collected included indicator bacteria species, the size and type of systems monitored, the primary purpose of testing, sampling frequency, test methods, the criteria for interpreting results, corrective actions, and management changes to limit human exposure. Of the 25 institutions to which surveys were sent, 19 (76%) responded. Fourteen reported testing for fecal indicator bacteria in fish systems. The most commonly tested indicator species were total (86%) and fecal (79%) coliform bacteria, which were detected by means of the membrane filtration method (64%). Multiple types and sizes of systems were tested, and the guidelines for testing and corrective actions were highly variable. Only three institutions performed additional tests to confirm the identification of indicator organisms. The results from this study can be used to compare bacterial monitoring practices and protocols in fish systems, as an aid to discussions relating to the accuracy and reliability of test results, and to help implement appropriate management responses. Received August 23, 2015; accepted December 29, 2015.
Endotoxin, coliform, and dust levels in various types of rodent bedding.
Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane
2010-03-01
Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating-tapping shaker. Paper bedding types contained significantly less endotoxin than did other bedding types; the highest levels of endotoxin were detected in hardwood and corncob beddings. The range of endotoxin content for each bedding type was: corncob bedding, 1913 to 4504 endotoxin units per gram (EU/g); hardwood bedding, 3121 to 5401 EU/g; corncob-paper mixed bedding, 1586 to 2416 EU/g; and paper bedding, less than 5 to 105 EU/g. Coliform counts varied from less than 10 to 7591 cfu/g in corncob beddings, 90 to 4010 cfu/g in corncob-paper mixed beddings, less than 10 to 137 cfu/g in hardwood beddings, and less than 10 cfu/g in paper beddings. Average dust content was less than 0.15% in all commercial bedding types. We conclude that paper bedding is the optimal bedding type for conducting LPS inhalation studies and that rodent bedding containing high levels of endotoxin may alter the results of respiratory and immunologic studies in rodents.
Cerna-Cortes, Jorge Francisco; Leon-Montes, Nancy; Cortes-Cueto, Ana Laura; Salas-Rangel, Laura P.; Helguera-Repetto, Addy Cecilia; Lopez-Hernandez, Daniel; Rivera-Gutierrez, Sandra; Fernandez-Rendon, Elizabeth; Gonzalez-y-Merchand, Jorge Alberto
2015-01-01
The aims of this study were to evaluate the microbiological quality and the occurrence of nontuberculous mycobacteria (NTM) in a variety of salads and sprouts from supermarkets and street vendors in Mexico City. Aerobic-mesophilic bacteria (AMB) were present in 100% of RTE-salads samples; 59% of samples were outside guidelines range (>5.17 log10 CFU per g). Although fecal coliforms (FC) were present in 32% of samples, only 8% of them exceeded the permissible limit (100 MPN/g). Regarding the 100 RTE-sprouts, all samples were also positive for AMB and total coliforms (TC) and 69% for FC. Seven NTM species were recovered from 7 salad samples; they included three M. fortuitum, two M. chelonae, one M. mucogenicum, and one M. sp. Twelve RTE-sprouts samples harbored NTM, which were identified as M. porcinum (five), M. abscessus (two), M. gordonae (two), M. mucogenicum (two), and M. avium complex (one). Most RTE-salads and RTE-sprouts had unsatisfactory microbiological quality and some harbored NTM associated with illness. No correlation between the presence of coliforms and NTM was found. Overall, these results suggest that RTE-salads and RTE-sprouts might function as vehicles for NTM transmission in humans; hence, proper handling and treatment before consumption of such products might be recommendable. PMID:25918721
Cerna-Cortes, Jorge Francisco; Leon-Montes, Nancy; Cortes-Cueto, Ana Laura; Salas-Rangel, Laura P; Helguera-Repetto, Addy Cecilia; Lopez-Hernandez, Daniel; Rivera-Gutierrez, Sandra; Fernandez-Rendon, Elizabeth; Gonzalez-y-Merchand, Jorge Alberto
2015-01-01
The aims of this study were to evaluate the microbiological quality and the occurrence of nontuberculous mycobacteria (NTM) in a variety of salads and sprouts from supermarkets and street vendors in Mexico City. Aerobic-mesophilic bacteria (AMB) were present in 100% of RTE-salads samples; 59% of samples were outside guidelines range (>5.17 log10 CFU per g). Although fecal coliforms (FC) were present in 32% of samples, only 8% of them exceeded the permissible limit (100 MPN/g). Regarding the 100 RTE-sprouts, all samples were also positive for AMB and total coliforms (TC) and 69% for FC. Seven NTM species were recovered from 7 salad samples; they included three M. fortuitum, two M. chelonae, one M. mucogenicum, and one M. sp. Twelve RTE-sprouts samples harbored NTM, which were identified as M. porcinum (five), M. abscessus (two), M. gordonae (two), M. mucogenicum (two), and M. avium complex (one). Most RTE-salads and RTE-sprouts had unsatisfactory microbiological quality and some harbored NTM associated with illness. No correlation between the presence of coliforms and NTM was found. Overall, these results suggest that RTE-salads and RTE-sprouts might function as vehicles for NTM transmission in humans; hence, proper handling and treatment before consumption of such products might be recommendable.
Ghosh, Sudipta; Mehla, Ram K; Sirohi, S K; Roy, Biswajit
2010-06-01
Thirty-six crossbred calves (Holstein cross) of 5 days of age were used to study the effect of garlic extract feeding on their performance up to the age of 2 months (pre-ruminant stage). They were randomly allotted into treatment and control groups (18 numbers in each group). Performance was evaluated by measuring average body weight (BW) gain, feed intake (dry matter (DM), total digestible nutrient (TDN) and crude protein (CP)), feed conversion efficiency (FCE; DM, TDN and CP), faecal score, faecal coliform count and feeding cost. Diets were the same for the both groups. In addition, treatment group received garlic extract supplementation at 250 mg/kg BW per day per calf. Body weight measured weekly, feed intake measured twice daily, proximate analysis of feeds and fodders analysed weekly, faecal scores monitored daily and faecal coliform count done weekly. There was significant increase in average body weight gain, feed intake and FCE and significant decrease in severity of scours as measured by faecal score and faecal coliform count in the treatment group compared to the control group (P < 0.01). Feed cost per kilogramme BW gain was significantly lower in the treatment group compared to control group (P < 0.01). The results suggest that garlic extract can be supplemented to the calves for better performance.
Luczkiewicz, A; Fudala-Ksiazek, S; Jankowska, K; Quant, B; Olańczuk-Neyman, K
2010-01-01
The occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, beta-lactam/beta-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale wastewater treatment model plant (M-WWTP), continuously supplied with the wastewater obtained from the full-scale WWTP. Number of fecal coliforms in raw (after mechanical treatment) and treated wastewater, as well as in aerobic chamber effluent was determined using selective medium. The selected strains were identified and examined for antibiotic resistance using Phoenix Automated Microbiology System (BD Biosciences, USA). The strains were identified as Escherichia coli (n=222), Klebsiella pneumoniae ssp. ozaenae (n=9), and Pantoea agglomerans (n=1). The isolate of P. agglomerans as well as 48% of E. coli isolates were sensitive to all antimicrobials tested. The most frequent resistance patterns were found for ampicillin: 100% of K. pneumoniae ssp. ozaenae and 41% of E. coli isolates. Among E. coli isolates 12% was regarded as multiple antimicrobial resistant (MAR). In the studied M-WWTP, the applied activated sludge processes reduced considerably the number of fecal coliforms, but increased the ratio of antimicrobial-resistant E. coli isolates to sensitive ones, especially among strains with MAR patterns.
Endotoxin, Coliform, and Dust Levels in Various Types of Rodent Bedding
Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane B
2010-01-01
Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating–tapping shaker. Paper bedding types contained significantly less endotoxin than did other bedding types; the highest levels of endotoxin were detected in hardwood and corncob beddings. The range of endotoxin content for each bedding type was: corncob bedding, 1913 to 4504 endotoxin units per gram (EU/g); hardwood bedding, 3121 to 5401 EU/g; corncob–paper mixed bedding, 1586 to 2416 EU/g; and paper bedding, less than 5 to 105 EU/g. Coliform counts varied from less than 10 to 7591 cfu/g in corncob beddings, 90 to 4010 cfu/g in corncob–paper mixed beddings, less than 10 to 137 cfu/g in hardwood beddings, and less than 10 cfu/g in paper beddings. Average dust content was less than 0.15% in all commercial bedding types. We conclude that paper bedding is the optimal bedding type for conducting LPS inhalation studies and that rodent bedding containing high levels of endotoxin may alter the results of respiratory and immunologic studies in rodents. PMID:20353693
Wohlsen, T D
2011-08-01
The equivalence of Oxoid (CM 1046) Brilliance((TM)) E. coli/coliform selective agar to mFC agar, as used in the Australian/New Zealand Standard Method to detect thermotolerant coliforms and Escherichia coli in water samples, was assessed. A total of 244 water samples were analysed in parallel over a 5-month period. Sewage effluent samples (n = 131, sites = 43), freshwater (n = 62, sites = 18) and marine/brackish water samples (n = 51, sites = 23) were analysed. The Wilcoxon matched-pairs signed-ranks test showed a varying degree of statistical difference between the two methods. All matrices had a higher recovery in the trial method. Enterococci faecalis, Aeromonas spp. and Vibrio spp. did not grow on the CM1046 agar, and Pseudomonas aeruginosa and Enterobacter aerogenes were inhibited. The use of CM 1046 for the detection and enumeration of E. coli and thermotolerant coliforms in water samples is a suitable alternative to the AS/NZS Standard Method. The use of CM1046 agar was less labour intensive and time consuming, as no secondary confirmation steps were required. Confirmed results could be reported within 24 h of sample analysis, as compared to 48 h with the reference method. Public health concerns can be addressed in a more efficient manner. © 2011 Unitywater. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Water-quality investigations of the Jordan River, Salt Lake County, Utah, 1980-82
Stephens, D.W.
1984-01-01
Water-quality studies were conducted on the Jordan River, Utah, to investigate specific problems: dissolved oxygen, toxic substances, sanitary quality, and turbidity and suspended sediment. The dissolved oxygen decreased from 8 milligrams per liter at the Jordan Narrows to less than 5 milligrams per liter at 500 North Street. Chemical oxygen demand increased about 23 percent and biochemical oxygen demand increased 90 percent. Nearly 78 percent of the water samples analyzed for total mercury exceeded the State intended-use standard of 0.05 microgram per liter. Concentrations of ammonia, cadmium, copper, lead, and zinc exceeded the standards periodically. The pesticides DDD, DDE, DDT, dieldrin, methoxychlor, and 2,4-D were occasionally detected in bottom materials. Most were present in quantities of less than 15 micrograms per kilogram. Concentrations of three indicator bacteria (total coliform, fecal coliform, and fecal streptococcus) increased in a downstream direction. Concentrations of total coliform bacteria often exceeded 5,000 colonies per 100 milliliters and concentrations of fecal coliform bacteria often exceeded 2,000 colonies per 100 milliliters. The primary sources of turbidity in the Jordan River are Utah Lake and discharges from the wastewater-treatment plants. Large values of turbidity were measured at the Jordan Narrows with a summer mean value of 88 nephelometer turbidity units (NTU) and a winter mean value of 43 NTU. (USGS)
Probabilistic assessment of compliance with the numerical criteria for fecal coliforms in rivers
NASA Astrophysics Data System (ADS)
Cha, YoonKyung
2017-04-01
Most guidelines for assessing fecal contamination in surface waters suggest that a waterbody is impaired if a certain percent or the geometric mean of samples exceeds the numerical criteria for fecal indicator organisms. However, this raw score approach is not able to account for the uncertainty and variability in the sample statistics. In a Bayesian hierarchical modeling approach, the uncertainty in the mean parameter is expressed as a posterior distribution, and the probability of not violating the criterion is referred to as the confidence of compliance (COC). Further, the spatiotemporal variability in the mean parameter can be quantified by imposing the hierarchical structure on the model. The monitoring data spanning 91 sites across the four major rivers (the Han, Geum, Yeongsan, and Nakdong) of South Korea for the years 2007-2016 were used. The Bayesian hierarchical model was developed for each river to predict the COC with the criteria for fecal coliforms. The established criteria for fecal coliforms are less than 10, 100, 200, and 1,000 CFU/100mL in the river whose water quality goal corresponds to Class Ia, Ib, II, and III, respectively. The model results suggested that the COC varied significantly by site, ranging from 0.0 to 98.9 percent across the four rivers. In the Geum, Yeongsan, and Nakdong Rivers, COC values in the upper river sections were substantially lower than those in the upper river sections. The model suggested that for all four rivers the spatial component, compared with annual and seasonal components, made the largest contribution to the variability in mean fecal coliforms. In all four rivers, mean levels for fecal coliform during the summer (July to September) were distinctly higher than those during other seasons. A decreasing pattern was clearly shown in the Yeongsan River over the recent decade, while monotonic increases or decreases were not shown in other three rivers.
Pant, Narayan Dutt; Poudyal, Nimesh; Bhattacharya, Shyamal Kumar
2016-06-07
Water-related diseases are of great concern in developing countries like Nepal. Every year, there are countless morbidity and mortality due to the consumption of unsafe drinking water. Recently, there have been increased uses of bottled drinking water in an assumption that the bottled water is safer than the tap water and its use will help to protect from water-related diseases. So, the main objective of this study was to analyze the bacteriological quality of bottled drinking water and that of municipal tap water. A total of 100 samples (76 tap water and 24 bottled water) were analyzed for bacteriological quality and pH. The methods used were spread plate method for total plate count (TPC) and membrane filter method for total coliform count (TCC), fecal coliform count (FCC), and fecal streptococcal count (FSC). pH meter was used for measuring pH. One hundred percent of the tap water samples and 87.5 % of the bottled water samples were found to be contaminated with heterotrophic bacteria. Of the tap water samples, 55.3 % were positive for total coliforms, compared with 25 % of the bottled water. No bottled water samples were positive for fecal coliforms and fecal streptococci, in contrast to 21.1 % and 14.5 % of the tap water samples being contaminated with fecal coliforms and fecal streptococci, respectively. One hundred percent of the tap water samples and 54.2 % of the bottled water samples had pH in the acceptable range. All of the municipal tap water samples and most of the bottled drinking water samples distributed in Dharan municipality were found to be contaminated with one or more than one type of indicator organisms. On the basis of our findings, we may conclude that comparatively, the bottled drinking water may have been safer (than tap water) to drink.
Gehr, Ronald; Wagner, Monika; Veerasubramanian, Priya; Payment, Pierre
2003-11-01
The City of Montreal Wastewater Treatment Plant uses enhanced physicochemical processes (ferric and/or alum coagulation) for suspended solids and phosphorus removal. The objective of this study was to assess the ability of peracetic acid (PAA), UV, or ozone to inactivate the indicator organisms fecal coliforms, Enterococci, MS-2 coliphage, or Clostridium perfringens in the effluent from this plant. PAA doses to reach the target fecal coliform level of 9000 CFU/100mL exceeded 6 mg/L; similar results were obtained for enterococci, and no inactivation of Clostridium perfringens was observed. However a 1-log reduction of MS-2 occurred at PAA doses of 1.5 mg/L and higher. It was expected that this effluent would have a high ozone demand, and would require relatively high UV fluences, because of relatively high effluent COD, iron and suspended solids concentrations, and low UV transmittance. This was confirmed herein. For UV, the inactivation curve for fecal coliforms showed the typical two-stage shape, with the target of 1000 CFU/100 mL (to account for photoreactivation) occurring in the asymptote zone at fluences >20 mJ/cm(2). In contrast, inactivation curves for MS-2 and Clostridium perfringens were linear. Clostridium perfringens was the most resistant organism. For ozone, inactivation was already observed before any residuals could be measured. The transferred ozone doses to reach target fecal coliform levels ( approximately 2-log reduction) were 30-50 mg/L. MS-2 was less resistant, but Clostridium perfringens was more resistant than fecal coliforms. The different behaviour of the four indicator organisms studied, depending on the disinfectant, suggests that a single indicator organism might not be appropriate. The required dose of any of the disinfectants is unlikely to be economically viable, and upstream changes to the plant will be needed.
Murphy, P; Dal Bello, F; O'Doherty, J; Arendt, E K; Sweeney, T; Coffey, A
2013-07-01
This study was designed to evaluate the effects of algal and yeast β-glucans on the porcine gastrointestinal microbiota, specifically the community of Lactobacillus, Bifidobacterium and coliforms. A total of 48 pigs were fed four diets over a 28-day period to determine the effect that each had on these communities. The control diet consisted of wheat and soya bean meal. The remaining three diets contained wheat and soya bean meal supplemented with β-glucan at 250 g/tonne from Laminaria digitata, Laminaria hyperborea or Saccharomyces cerevisiae. Faecal samples were collected from animals before feeding each diet and after the feeding period. The animals were slaughtered the following day and samples were collected from the stomach, ileum, caecum, proximal colon and distal colon. Alterations in Lactobacillus in the gastrointestinal tract (GIT) were analysed using denaturing gradient gel electrophoresis (DGGE) profiles generated by group-specific 16S rRNA gene PCR amplicons. Plate count analysis was also performed to quantify total coliforms. DGGE profiles indicated that all β-glucan diets provoked the emergence of a richer community of Lactobacillus. The richest community of lactobacilli emerged after feeding L. digitata (LD β-glucan). Plate count analysis revealed that the L. hyperborea (LH β-glucan) diet had a statistically significant effect on the coliform counts in the proximal colon in comparison with the control diet. β-glucan from L. digitata and S. cerevisiae also generally reduced coliforms but to a lesser extent. Nevertheless, the β-glucan diets did not significantly reduce levels of Lactobacillus or Bifidobacterium. DGGE analysis of GIT samples indicated that the three β-glucan diets generally promoted the establishment of a more varied range of Lactobacillus species in the caecum, proximal and distal colon. The LH β-glucan had the most profound reducing effect on coliform counts when compared with the control diet and diets supplemented with L. digitata and S. cerevisiae β-glucans.
Klipstein, Frederick A.; Engert, Richard F.
1977-01-01
Cholera toxin (CT) and the heat-labile (LT) toxin of Escherichia coli are known to share antigenic properties. The present study examined the immunological relationship of CT and the LT and heat-stable (ST) toxins of E. coli, Klebsiella pneumoniae, and Enterobacter cloacae. The neutralizing capacity of equine CT antiserum and of antiserum raised in rabbits to the LT toxin of the three species of coliform bacteria was evaluated by determining their capacity to inhibit the action of purified CT and semipurified ultrafiltration preparations of the coliform LT and ST toxins in inducing water secretion as assayed by the in vivo marker perfusion technique in the rat jejunum. One milliliter of antiserum to CT and to E. coli and Klebsiella LT completely neutralized the secretory action of each of these three toxins; effective serial dilutions of CT antiserum extended to 1 to 4, whereas those of the antisera to LT were limited to 1 to 2 in most instances. One milliliter of antiserum to E. cloacae LT partially neutralized each of the three coliform LT toxins; serial dilutions were inactive. Antiserum to E. cloacae LT did not neutralize CT. Antiserum to CT and to each of the three coliform LT toxins also had a weak neutralizing effect on the ST toxins of E. coli and Klebsiella, but they did not affect E. cloacae ST. Adsorption of the antiserum to CT and to each of the three LT toxins by incubation with a heat-inactivated preparation of either the homologous or a heterologous LT toxin completely abolished the neutralizing capacity of the antisera towards both LT and ST. These observations indicate that the immunological interrelationship of CT and E. coli LT extends to the LT toxins of Klebsiella and E. cloacae and, further, that these immunological properties are shared to a lesser extent by the ST toxins of E. coli and Klebsiella. PMID:332637
Rubio-Arias, Hector; Rey, Nora I; Quintana, Rey M; Nevarez, G Virginia; Palacios, Oskar
2011-06-01
Lago de Colina (Colina Lake) is located about 180 km south of the city of Chihuahua (Mexico), and during the Semana Santa (Holy Week) vacation period its recreational use is high. The objective of this study was to quantify coliform and heavy metal levels in this water body before and after the Holy Week vacation period in 2010. Twenty sampling points were randomly selected and two water samples were collected at each point near the surface (0.30 m) and at 1 m depth. After the Holy Week vacation the same twenty points were sampled at the same depths. Therefore, a total 80 water samples were analyzed for fecal and total coliforms and levels of the following metals: Al, As, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si and Zn. It was hypothesized that domestic tourism contaminated this water body, and as a consequence, could have a negative impact on visitor health. An analysis of variance (ANOVA) study was performed for each element and its interactions considering a factorial design where factor A was sample date and factor B was sample depth. Fecal coliforms were only detected at eight sampling points in the first week, but after Holy Week, both fecal and total coliforms were detected at most sampling points. The concentrations of Al, B, Na, Ni and Se were only statistically different for factor A. The levels of Cr, Cu, K and Mg was different for both date and depth, but the dual factor interaction was not significant. The amount of Ca and Zn was statistically different due to date, depth and their interaction. No significant differences were found for any factor or the interaction for the elements As, Fe and Mn. Because of the consistent results, it is concluded that local tourism is contaminating the recreational area of Colina Lake, Chihuahua, Mexico.
Donkor, Eric S; Lanyo, R; Kayang, Boniface B; Quaye, Jonathan; Edoh, Dominic A
2010-09-01
The occurrence of pathogens in the internal parts of vegetables is usually associated with irrigation water or contaminated soil and could pose risk to consumers as the internalised pathogens are unaffected by external washing. This study was carried out to assess the rate of internalisation of microbes in common Ghanaian vegetables. Standard microbiological methods were employed in microbial enumeration of vegetables collected at the market and farm levels, as well as irrigation water and soil samples. The overall mean counts of vegetables were 4.0 x 10(3) cfu g(-1); 8.1 x 10(2) cfu g(-1); 2.0 x 10(2) cfu g(-1); 3.5 x 10(2) cfu g(-1) for total bacteria, coliform counts, faecal coliform counts and yeast counts, respectively. The rate of internalisation of coliforms in vegetables irrigated with stream/well water was 2.7 times higher than those irrigated with pipe water. The mean coliform counts (4.7 x 10(7) cfu g(-1)) and faecal coliform counts (1.8 x 10(6) cfu g(-1)) of soil samples were similar to those of stream water suggesting both sources exerted similar contamination rates on the vegetables. Generally, there were no significant variations between the rates of internalisation of microbes at the market and farm levels at p < 05, indicating that internalisation of microbes in the vegetables mainly occurred at the farm level. The study has shown that microbial contamination of vegetables in Ghana is not limited to the external surface, but internal vegetable parts could harbour high microbial loads and pose risk to consumers. Safety practices associated with the commodity should therefore not be limited to external washing only. There is the additional need of heating vegetables to eliminate microbes both externally and internally before consumption.
Rubio-Arias, Hector; Rey, Nora I.; Quintana, Rey M.; Nevarez, G. Virginia; Palacios, Oskar
2011-01-01
Lago de Colina (Colina Lake) is located about 180 km south of the city of Chihuahua (Mexico), and during the Semana Santa (Holy Week) vacation period its recreational use is high. The objective of this study was to quantify coliform and heavy metal levels in this water body before and after the Holy Week vacation period in 2010. Twenty sampling points were randomly selected and two water samples were collected at each point near the surface (0.30 m) and at 1 m depth. After the Holy Week vacation the same twenty points were sampled at the same depths. Therefore, a total 80 water samples were analyzed for fecal and total coliforms and levels of the following metals: Al, As, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si and Zn. It was hypothesized that domestic tourism contaminated this water body, and as a consequence, could have a negative impact on visitor health. An analysis of variance (ANOVA) study was performed for each element and its interactions considering a factorial design where factor A was sample date and factor B was sample depth. Fecal coliforms were only detected at eight sampling points in the first week, but after Holy Week, both fecal and total coliforms were detected at most sampling points. The concentrations of Al, B, Na, Ni and Se were only statistically different for factor A. The levels of Cr, Cu, K and Mg was different for both date and depth, but the dual factor interaction was not significant. The amount of Ca and Zn was statistically different due to date, depth and their interaction. No significant differences were found for any factor or the interaction for the elements As, Fe and Mn. Because of the consistent results, it is concluded that local tourism is contaminating the recreational area of Colina Lake, Chihuahua, Mexico. PMID:21776236
2007-06-01
Love, G. Lovelace, J. Stewart, and B. Robinson. 2005. Methods to detect and genotype coliphages in water and shellfish. Methodology for a demonstra... Water fecal coliform counts (colony forming units (cfu) per 100 mL of water ) ranged from 100 to 490,000 (mean=21,381, standard deviation =74,541...100) in St. Bernard Parish and the Lower Ninth Ward polders. The LADEQ primary contact recreational water quality criterion for fecal coliforms is
1976-07-01
coliform, fecal coliform, and fecal streptococcus densities. Salmonellae and shigellae were not recovered from either upstream water samples or from...fecal streptococci, Clostridlum perfringens) and enteric pathogens (salmonellae, shigellae , enteroviruses, infectious hepatitus agent) have beeii shown...the Mississippi River that was polluted with Shigella sonnet (5,32). 49W 1.----Wq W P4 p TABLE 1. Incidence of selected enteric diseases during 1975 in
Nechaeva, O V; Tikhomirova, E I; Zayarsky, D A; Bespalova, N V; Glinskaya, E V; Shurshalova, N F; Al Bayati, B M; Babailova, A I
2017-04-01
The dynamics of microbial biofilm formation by standard strain and by clinical strains of uropathogenic coliform bacteria was investigated in vitro and the effect of sublethal concentrations of the polymer compound polyazolidinammonium modified with iodine hydrate ions on the initial stages of biofilm formation was assessed. Treatment of immunological plate wells with the polymeric compound prevented film formation, especially in case of clinical E. coli strain carrying FimH virulence gene.
Gill, C O; Bryant, J; Badoni, M
2001-02-15
Ten 12-kg lots of manufacturing beef from a single packing plant were obtained from a hamburger patty manufacturing plant. Each lot was divided into two, 6-kg portions, one of which was not treated while the other was treated with water of 85 degrees C. A portion from one lot was treated for 15 s. A portion from each of three lots was treated for 30 s, three portions were treated for 45 s, and three were treated for 60 s. Twenty-five pieces of meat from each portion were swabbed over areas of 100 cm2. Subsequently, each portion was first coarsely ground then finely ground, with twenty-five 100-g samples being taken from each portion at each stage of grinding. Each swab and sample of ground meat was separately processed for the enumeration of total aerobic counts, coliforms and Escherichia coli at levels of detection of 1 cfu/cm2, 1 cfu/100 cm2 and 1 cfu/100 cm2, respectively, for swab samples; and at a level of detection of 1 cfu/g for all three types of bacteria in samples of ground beef. A 250-kg batch of manufacturing beef was treated with water of 85 degrees C for 60 s. The product was processed through commercial equipment for manufacturing frozen hamburger patties. The flavour of patties prepared from the pasteurized product was compared with the flavour of patties prepared during normal commercial operation of the equipment. The weight of the manufacturing beef was not affected by the treatments. Similar total numbers of coliforms or E. coli were recovered per 2500 cm2 from the 25 swab samples or per 25 g from the 25 ground beef samples from each untreated portion. As the ratio of the surface area in cm2 to the weight in g would likely be < or = 1, the similar numbers indicated that swab sampling was inefficient for recovering coliforms and E. coli from the meat. However, coliforms and E. coli were recovered more frequently from swab than from ground beef samples from treated portions. Thus, some swabs from all three portions of beef treated for 30 s yielded coliforms and E. coli, but samples from portions treated for 45 or 60 s yielded few coliforms and no E. coli. The numbers recovered from the treated and untreated portions indicated that treatments for 45 or 60 s reduced both coliform and E. coli numbers by two orders of magnitude. The flavours of cooked patties prepared from the meat pasteurized with water of 85 degrees C for 60 s were not distinguished from the normal commercial product. The data indicate that pasteurizing manufacturing beef with water of 85 degrees C for 45 s could be a practicable treatment for enhancing the microbiological safety of frozen hamburger patties.
Francy, D.S.; Hart, T.L.; Virosteck, C.M.
1996-01-01
Bacterial injury, survival, and regrowth were investigated by use of replicate flow-through incubation chambers placed in the Cuyahoga River or Lake Erie in the greater Cleveland metropolitan area during seven 4-day field studies. The chambers contained wastewater or combined-sewer-overflow (CSO) effluents treated three ways-unchlorinated, chlorinated, and dechlorinated. At timestep intervals, the chamber contents were analyzed for concentrations of injured and healthy fecal coliforms by use of standard selective and enhanced-recovery membrane-filtration methods. Mean percent injuries and survivals were calculated from the fecal-coliform concentration data for each field study. The results of analysis of variance (ANOVA) indicated that treatment affected mean percent injury and survival, whereas site did not. In the warm-weather Lake Erie field study, but not in the warm-weather Cuyahoga River studies, the results of ANOVA indicated that dechlorination enhanced the repair of injuries and regrowth of chlorine-injured fecal coliforms on culture media over chlorination alone. The results of ANOVA on the percent injury from CSO effluent field studies indicated that dechlorination reduced the ability of organisms to recover and regrow on culture media over chlorination alone. However, because of atypical patterns of concentration increases and decreases in some CSO effluent samples, more work needs to be done before the effect of dechlorination and chlorination on reducing fecal-coliform concentrations in CSO effluents can be confirmed. The results of ANOVA on percent survivals found statistically significant differences among the three treatment methods for all but one study. Dechlorination was found to be less effective than chlorination alone in reducing the survival of fecal coliforms in wastewater effluent, but not in CSO effluent. If the concentration of fecal coliforms determined by use of the enhanced-recovery method can be predicted accurately from the concentration found by use of the standard method, then increased monitoring and expense to detect chlorine-injured organisms would be unnecessary. The results of linear regression analysis, however, indicated that the relation between enhanced-recovery and standard-method concentrations was best represented when the data were grouped by treatment. The model generated from linear regression of the unchlorinated data set provided an accurate estimate of enhanced-recovery concentrations from standard-method concentrations, whereas the models generated from the chlorinated and dechlorinated data sets did not. In addition, evaluation of fecal-coliform concentrations found in field studies in terms of Ohio recreational water-quality standards showed that concentrations obtained by standard and enhanced-recovery methods were not comparable. Sample treatment and analysis methods were found to affect the percentage of samples meeting and exceeding Ohio's bathing-water, primary-contact, and secondary-contact standards. Therefore, determining the health risk of swimming in receiving waters was often difficult without information on enhanced-recovery method concentrations and was especially difficult in waters receiving high proportions of chlorinated or dechlorinated effluents.
Survival and detection of coliforms, Enterobacteriaceae, and gram-negative bacteria in Greek yogurt.
Hervert, C J; Martin, N H; Boor, K J; Wiedmann, M
2017-02-01
Despite the widespread use of coliforms as indicator bacteria, increasing evidence suggests that the Enterobacteriaceae (EB) and total gram-negative groups more accurately reflect the hygienic status of high-temperature, short-time pasteurized milk and processing environments. If introduced into milk as postpasteurization contamination, these bacteria may grow to high levels and produce a wide range of sensory-related defects. However, limited information is available on the use and survival of bacterial hygiene indicators in dairy products outside of pasteurized fluid milk and cheese. The goal of this study was to (1) provide information on the survival of a diverse set of bacterial hygiene indicators in the low pH environment of Greek yogurt, (2) compare traditional and alternative detection methods for their ability to detect bacterial hygiene indicators in Greek yogurt, and (3) offer insight into optimal hygiene indicator groups for use in low-pH fermented dairy products. To this end, we screened 64 bacterial isolates, representing 24 dairy-relevant genera, for survival and detection in Greek yogurt using 5 testing methods. Before testing, isolates were inoculated into plain, 0% fat Greek yogurt (pH 4.35 to 4.65), followed by a 12-h hold period at 4 ± 1°C. Yogurts were subsequently tested using Coliform Petrifilm (3M, St. Paul, MN) to detect coliforms; Enterobacteriaceae Petrifilm (3M), violet red bile glucose agar and the D-Count (bioMérieux, Marcy-l'Étoile, France) to detect EB; and crystal violet tetrazolium agar (CVTA) to detect total gram-negative bacteria. Overall, the non-EB gram-negative isolates showed significantly larger log reductions 12 h after inoculation into Greek yogurt (based on bacterial numbers recovered on CVTA) compared with the coliform and noncoliform EB isolates tested. The methods evaluated varied in their ability to detect different microbial hygiene indicators in Greek yogurt. Crystal violet tetrazolium agar detected the highest portion of coliforms, whereas EB Petrifilm detected the highest portion of EB, as well as highest portion of total gram-negative bacteria. Additionally, the D-Count method allowed for faster detection of EB in yogurt by generating results in approximately 13 h rather than the 24 h required when using EB Petrifilm and violet red bile glucose agar. Results from this study indicate that the coliform and EB groups encompass a broad range of dairy-relevant gram-negative bacteria with the ability to survive in Greek yogurt, supporting their use as microbial hygiene indicator groups in low-pH fermented dairy products. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Rai, Prabhat Kumar; Tripathi, B D
2007-10-01
A total of 144 samples of water used for irrigation were collected from Dinapur, DLW sewage treatment plant and river water of Ganga at Rajghat and 258 irrigated vegetable samples were collected from nearby agricultural fields in the close vicinity of three treatment plants and examined using standard procedures for coliform and viable counts and the presence of Escherichia coli, Salmonella, Clostridium and Vibrio during the winter and rainy seasons. Irrigation water from Rajghat drain had significantly higher coliform counts by location and season than the water from the Dinapur and DLW. Although all the vegetables had coliform counts higher than the recommended standard (range 3.40 - 6.38 log10 cfuml(-1)), spinach and cabbage had significantly higher (p < 0.05) counts compared to other vegetables during the dry season. Salmonella was significantly more likely to be detected during the rainy season than during the dry season. Contaminated vegetable intake may pose a serious threat to human health.
Microbiological survey of five poultry processing plants in the UK.
Mead, G C; Hudson, W R; Hinton, M H
1993-07-01
1. Neck skin samples were taken from chickens and turkeys at all the main stages of processing to monitor changes in total viable count (TVC) and counts of coliforms and pseudomonads. 2. Processing reduced TVC by up to 100-fold. Geometric mean counts after packaging were log10 4.4 to 5.3 CFU/g whilst corresponding counts of coliforms were 2.7 to 3.8 CFU/g. 3. Increases in mean TVC or coliforms as a result of either defeathering or evisceration did not exceed 0.6 log. 4. Pseudomonads represented only a minor fraction of the initial microflora of the bird and were often reduced by scalding to a figure which could not be detected by direct plating of samples; however, subsequent contamination resulted in means between log10 2.9 and 4.0 CFU/g for packaged carcases. 5. Although Staphylococcus aureus was readily isolated from defeathering equipment, mean counts from defeathered carcases were always below log10 3.0 CFU/g.
NASA Astrophysics Data System (ADS)
Barrera-Díaz, C.; Ureña-Nuñez, F.; Campos, E.; Palomar-Pardavé, M.; Romero-Romo, M.
2003-07-01
This study reports on the attainment of optimal conditions for two electrolytic methods to treat wastewater: namely, electrocoagulation and particle destabilization of a highly polluted industrial wastewater, and electrochemically induced oxidation induced by in situ generation of Fenton's reactive. Additionally, a combined method that consisted of electrochemical treatment plus γ-irradiation was carried out. A typical composition of the industrial effluent treated was COD 3400 mg/l, color 3750 Pt/Co units, and fecal coliforms 21000 MPN/ml. The best removal efficiency was obtained with electrochemical oxidation induced in situ , that resulted in the reduction of 78% for the COD, 86% color and 99.9% fecal coliforms removal. A treatment sequence was designed and carried out, such that after both electrochemical processes, a γ-irradiation technique was used to complete the procedure. The samples were irradiated with various doses in an ALC γ-cell unit provided with a Co-60 source. The removal efficiency obtained was 95% for the COD values, 90% color and 99.9% for fecal coliforms.
Bacteria and Nutrients in the Obhur Recreational Sharm, Jeddah, Saudi Arabia
NASA Astrophysics Data System (ADS)
Turki, Adnan; Mudarris, Mohammed
2013-04-01
Environmental pollution that render waters along the recreational shore unsatisfactory for use by the general public has become a global health problem. This study was carried out to examine the marine waters in sampling stations located at Sharm Obhur (North of Jeddah). These parameters included: total coliform (TC), l fecal coliform (FC) and nutrients (NO2-N, NO3-N, NH4-N and PO4-P). A comparison of the mean values of nutrients in Sharm Obhur with those of other locations in the Red Sea suggests that the mean levels of nutrients were similar to those of unpolluted areas. TC and FC counts were higher at the north sampling stations than the south ones, and with little variations between their numbers. FC was not recovered at stations to the south. The study shows that TC and FC counts at all sampling stations similar to the levels reported for normal unpolluted sea water. Keywords: Pollution, Nutrients, Coliforms, Sharm Obhur, Red Sea.
Virological and bacteriological quality of drinking water in Ethiopia
NASA Astrophysics Data System (ADS)
Bedada, Tesfaye Legesse; Mezemir, Walelign Dessie; Dera, Firehiwot Abera; Sima, Waktole Gobena; Gebre, Samson Girma; Edicho, Redwan Muzeyin; Biegna, Almaz Gonfa; Teklu, Dejenie Shiferaw; Tullu, Kassu Desta
2018-05-01
Since unsafe water is responsible for many illness, deaths, and economic failure, water quality monitoring is essential. A cross-sectional study was conducted on 218 drinking waters samples collected between February and June 2016 to assess water quality using phages by the help of CB390 E. coli host, plaque assay; multiple tube fermentation for coliforms and pour plate for heterotrophic bacteria at Ethiopian Public Health Institute. Heterotrophic plate count greater than 100 cfu/ml was noted in 41 samples and detections of total and thermotolerant coliforms and E. coli in 38, 24, and 10 samples, respectively, and no phages detection in chlorinated waters. While heterotrophic plate count greater than 100 cfu/ml was observed in 100 samples and detections of total and thermotolerant coliforms, E. coli, and phages in 75, 60, 42, and 5 samples, respectively, for untreated waters. The majority of the waters contained indicators above standard limits. This indicates that the sources are contaminated and they are potential threats for health. Hence, regular water monitoring should be a priority agenda.
Wilhelm, Lance J.; Maluk, Terry L.
1998-01-01
IntroductionHigh levels of fecal-indicator bacteria in rivers and streams can indicate the possible presence of pathogenic (disease-causing) microorganisms. Cholera, typhoid fever, bacterial dysentery, infectious hepatitis, and cryptosporidiosis are some of the well known waterborne diseases that spread through water contaminated and fecal matter. Eye, ear, nose, and throat infections also can result from contact with contaminated water. In general, methods are not routinely used to detect pathogens in water. Instead, bacteria such as total coliforms, fecal coliforms, fecal streptococci, Escherichia coli (E coli), and enterococci are used as indicators of sanitary water quality, because they are present in high numbers in fecal material and have been shown to be associated with some waterborne disease-causing organisms. Indicator bacteria usually are harmless, more plentiful, and easier to detect than pathogens. The concentration of bacteria in a sample of water is usually expressed as the number of bacterial colonies per 100 milliliters of water sample.As part of the U.S. Geological Survey National Water-Quality Assessment Program, 145 samples were collected and analyzed for selected water-quality constituents, fecal coliforms, and fecal streptococci at 17 sites in North and South Carolina from October 1995 through September 1996. Of the original 17 sites, 4 in South Carolina were sampled for E. coli and total coliforms from April through September 1997. At two sites, this sampling continued from October 1997 through April 1998.
Yassin, Maged Mohammed; Amr, Salem S Abu; Al-Najar, Husam M
2006-12-01
To assess the contamination level of total and faecal coliforms in water wells and distribution networks, and their association with human health in Gaza Governorate, Gaza Strip. Data were obtained from the Palestinian Ministry of Health on contamination of total and faecal coliforms in water wells and distribution networks, and on the incidence of water-related diseases in Gaza Governorate. An interview questionnaire was conducted with 150 residents of Gaza. The contamination level of total and faecal coliforms exceeded that of the World Health Organization (WHO) limit for water wells and networks. However, the contamination percentages in networks were higher than that in wells. Giardiasis was strongly correlated with faecal coliform contamination in water networks (r=0.7) compared with diarrhoeal diseases and hepatitis A (r=0.3 and 0.1, respectively). Diarrhoeal diseases were the highest self-reported diseases among interviewees in Gaza city. Such diseases were more prevalent among people using municipal water than people using desalinated water and water filtered at home for drinking (OR=1.6). Intermittent water supply and sewage flooding seemed to contribute largely to self-reported diseases. People in Gaza Strip have good knowledge on drinking water contamination, and this is reflected in good practice. Water quality has deteriorated in Gaza Strip. This may contribute to the prevalence of water-related diseases. Self-reported diseases among interviewees in Gaza City were associated with source of drinking water, intermittent water supply, sewage flooding and age of water, and wastewater networks.
Bacteriological quality of drinking water in Nyala, South Darfur, Sudan.
Abdelrahman, Amira Ahmed; Eltahir, Yassir Mohammed
2011-04-01
The objective of this study was to determine the bacterial contaminations in drinking water in Nyala city, South Darfur, Sudan with special reference to the internally displaced people camps (IDPs). Two hundred and forty water samples from different sites and sources including bore holes, hand pumps, dug wells, water points, water reservoir and household storage containers were collected in 2009. The most probable number method was used to detect and count the total coliform, faecal coliform and faecal enterococci. Results revealed that the three indicators bacteria were abundant in all sources except water points. Percentages of the three indicators bacteria count above the permissible limits for drinking water in all samples were 46.4% total coliform, 45.2% faecal coliform and 25.4% faecal enterococci whereas the highest count of the indicators bacteria observed was 1,600 U/100 ml water. Enteric bacteria isolated were Escherichia coli (22.5%), Enterococcus faecalis (20.42%), Klebsiella (15.00%), Citrobacter (2.1%) and Enterobacter (3.33%). The highest contamination of water sources was observed in household storage containers (20%) followed by boreholes (11.25%), reservoirs (6.24%), hand pumps (5.42%) and dug wells (2.49%). Contamination varied from season to season with the highest level in autumn (18.33%) followed by winter (13.75%) and summer (13.32%), respectively. All sources of water in IDP camps except water points were contaminated. Data suggested the importance of greater attention for household contamination, environmental sanitation control and the raise of awareness about water contamination.
Use of hot water for beef carcass decontamination.
Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R
1998-01-01
Hot water treatment of beef carcass surfaces for reduction of Escherichia coli O157:H7, Salmonella typhimurium, and various indicator organisms was studied using a model carcass spray cabinet. Paired hot carcass surface regions with different external fat characteristics (inside round, outside round, brisket, flank, and clod) were removed from carcasses immediately after the slaughter and dressing process. All cuts were inoculated with bovine feces containing 10(6)/g each of rifampicin-resistant E. coli O157:H7 and S. typhimurium, or with uninoculated bovine feces. Surfaces then were exposed to a carcass water wash or a water wash followed by hot water spray (95 degrees C). Counts of rifampicin-resistant Salmonella and E. coli or aerobic plate count (APC) and coliform counts were conducted before and after each treatment. All treatments significantly reduced levels of pathogens from the initial inoculation level of 5.0 log(10) CFU/cm2. Treatments including hot water sprays provided mean reductions of initial counts for E. coli O157:H7 and S. typhimurium of 3.7 and 3.8 log, APC reductions of 2.9 log, and coliform and thermotolerant coliform count reductions of 3.3 log. The efficacy of hot water treatments was affected by the carcass surface region, but not by delaying the treatment (30 min) after contaminating the surface. Verification of efficacy of hot water interventions used as critical control points in a hazard analysis critical control point (HACCP) system may be possible using coliform counts.
The impact of hygiene and localised treatment on the quality of drinking water in Masaka, Rwanda.
Uwimpuhwe, Monique; Reddy, Poovendhree; Barratt, Graham; Bux, Faizal
2014-01-01
The worldwide prevalence of waterborne diseases has been attributed to the lack of safe water, inadequate sanitation and hygiene. This study evaluated socio-demographic factors, microbiological quality of water at source and point of use (POU) at households, water handling and sanitation practices in a rural Rwandan community. Thirty five water samples from the source, Nyabarongo River, and water at point of use (POU) treated with the Slow Sand Filter (SSF) and Sûr'Eau methods, were analysed for total coliform and faecal coliform counts. Turbidity was measured in household samples. A structured questionnaire regarding water collection, storage, usage and waterborne disease awareness was administered to 324 women. Despite the significant reduction in coliforms and faecal coliforms from the Nyabarongo River following treatment using either SSF or Sûr'Eau, the water at point of use was found to be unsafe for human consumption. The frequency of diarrheal diseases were significantly higher among people who did not wash hands before food preparation (P = 0.002) and after using a toilet (P = 0.007) than among those who did. There was a statistically significant association between education levels and water treatment practices at the households (P < 0.05). Participants had limited knowledge regarding water storage practices for prevention of household water contamination. A combination of treatment methods with appropriate water handling should be considered. In addition, education is a fundamental precursor to advocating water treatment at POU.
Coliform Bacteria and Nitrogen Fixation in Pulp and Paper Mill Effluent Treatment Systems
Gauthier, Francis; Neufeld, Josh D.; Driscoll, Brian T.; Archibald, Frederick S.
2000-01-01
The majority of pulp and paper mills now biotreat their combined effluents using activated sludge. On the assumption that their wood-based effluents have negligible fixed N, and that activated-sludge microorganisms will not fix significant N, these mills routinely spend large amounts adding ammonia or urea to their aeration tanks (bioreactors) to permit normal biomass growth. N2 fixation in seven Eastern Canadian pulp and paper mill effluent treatment systems was analyzed using acetylene reduction assays, quantitative nitrogenase (nifH) gene probing, and bacterial isolations. In situ N2 fixation was undetectable in all seven bioreactors but was present in six associated primary clarifiers. One primary clarifier was studied in greater detail. Approximately 50% of all culturable cells in the clarifier contained nifH, of which >90% were Klebsiella strains. All primary-clarifier coliform bacteria growing on MacConkey agar were identified as klebsiellas, and all those probed contained nifH. In contrast, analysis of 48 random coliform isolates from other mill water system locations showed that only 24 (50%) possessed the nifH gene, and only 13 (27%) showed inducible N2-fixing activity. Thus, all the pulp and paper mill primary clarifiers tested appeared to be sites of active N2 fixation (0.87 to 4.90 mg of N liter−1 day−1) and a microbial community strongly biased toward this activity. This may also explain why coliform bacteria, especially klebsiellas, are indigenous in pulp and paper mill water systems. PMID:11097883
Assessment of the quality of water from hand-dug wells in ghana.
Nkansah, Marian Asantewah; Boadi, Nathaniel Owusu; Badu, Mercy
2010-04-26
This study focused upon the determination of physicochemical and microbial properties, including metals, selected anions and coliform bacteria in drinking water samples from hand-dug wells in the Kumasi metropolis of the Republic of Ghana. The purpose was to assess the quality of water from these sources. Ten different water samples were taken from different parts of Kumasi, the capital of the Ashanti region of Ghana and analyzed for physicochemical parameters including pH, electrical conductivity, total dissolved solids, alkalinity total hardness and coliform bacteria. Metals and anions analyzed were Ca, Mg, Fe, Mn, NO(3) (-), NO(2) (-), SO(4) (2-), PO(4) (2-), F(-) and Cl(-). Bacteria analysed were total coliform and Escherichia coli.THE DATA SHOWED VARIATION OF THE INVESTIGATED PARAMETERS IN SAMPLES AS FOLLOWS: pH, 6.30-0.70; conductivity (EC), 46-682 muS/cm; PO(4) (3-), 0.67-76.00 mg/L; F(-), 0.20-0.80 mg/L; NO(3) (-), 0-0.968 mg/L; NO(2) (-), 0-0.063 mg/L; SO(4) (2-), 3.0-07.0 mg/L; Fe, 0-1.2 mg/L; Mn, 0-0.018 mg/L. Total coliform and Escherichia coli were below the minimum detection limit (MDL) of 20 MPN per 100 ml in all the samples. The concentrations of most of the investigated parameters in the drinking water samples from Ashanti region were within the permissible limits of the World Health Organization drinking water quality guidelines.
Berrang, M E; Dickens, J A; Musgrove, M T
2000-11-01
Scalding has been found to lower the levels of Campylobacter on broiler carcasses. However, the numbers recovered from whole-carcass rinse samples increase following defeathering. This study was undertaken to examine the effect of a second scald applied after defeathering on microbial levels recovered from carcass rinses. Four treatments were evaluated: 1) immersion at 60 C for 28 s 30 min after defeathering, 2) immersion at 60 C for 28 s immediately after defeathering, 3) spray at 73 C for 20 s 30 min after defeathering, and 4) spray at 71 C for 20 s immediately after defeathering. As reported earlier, a significant increase in Campylobacter counts per mL whole carcass rinse was noted after carcasses were defeathered. However, when applied 30 min after defeathering, neither the immersion nor the spray second scald treatments lowered the Campylobacter counts. Likewise, neither treatment had any affect on Escherichia coli or coliform bacteria counts, even though total counts were slightly reduced by the treatments. When the second scald treatment immediately followed defeathering, the same trends were observed. Campylobacter counts after the second scald remained at the postpick levels, as did counts for E. coli and coliform bacteria, but total plate counts were slightly reduced. Overall, it would appear that a postscald treatment gentle enough not to alter the carcass appearance or meat quality would not effectively lower Campylobacter, E. coli, or coliform bacteria counts.
Blumenthal, U. J.; Mara, D. D.; Peasey, A.; Ruiz-Palacios, G.; Stott, R.
2000-01-01
Three different approaches for establishing guidelines for the microbiological quality of treated wastewater that is reused for agriculture are reviewed. These approaches have different objectives as their outcomes: the absence of faecal indicator organisms in the wastewater, the absence of a measurable excess of cases of enteric disease in the exposed population and a model-generated estimated risk below a defined acceptable risk. If the second approach (using empirical epidemiological studies supplemented by microbiological studies of the transmission of pathogens) is used in conjunction with the third approach (using a model-based quantitative risk assessment for selected pathogens) a powerful tool is produced that aids the development of regulations. This combined approach is more cost-effective than the first approach and adequately protects public health. The guideline limit for faecal coliform bacteria in unrestricted irrigation (< or = 1000 faecal coliform bacteria/ 100 ml) is valid, but for restricted irrigation < or = 10(5) faecal coliform bacteria/100 ml is recommended when adult farmworkers are exposed to spray irrigation. A limit of < or = 10(3) faecal coliform bacteria/100 ml is recommended if flood irrigation is used or children are exposed. The guideline limit for nematode eggs for both types of irrigation is adequate except when conditions favour the survival of nematode eggs and where children are exposed; in these cases it should be reduced from < or = 1 egg/l to < or = 0.1 egg/l. PMID:11019459
Van Cuyk, S.; Siegrist, R.L.; Lowe, K.; Harvey, R.W.
2004-01-01
Soil treatment of wastewater has the potential to achieve high purification efficiency, yet the understanding and predictability of purification with respect to removal of viruses and other pathogens is limited. Research has been completed to quantify the removal of virus and bacteria through the use of microbial surrogates and conservative tracers during controlled experiments with three-dimensional pilot-scale soil treatment systems in the laboratory and during the testing of full-scale systems under field conditions. The surrogates and tracers employed included two viruses (MS-2 and PRID-1 bacteriophages), one bacterium (ice-nucleating active Pseudomonas), and one conservative tracer (bromide ion). Efforts have also been made to determine the relationship between viruses and fecal coliform bacteria in soil samples below the wastewater infiltrative surface, and the correlation between Escherichia coil concentrations measured in percolating soil solution as compared with those estimated from analyses of soil solids. The results suggest episodic breakthrough of virus and bacteria during soil treatment of wastewater and a 2 to 3 log (99-99.9%) removal of virus and near complete removal of fecal coliform bacteria during unsaturated flow through 60 to 90 cm of sandy medium. Results also suggest that the fate of fecal coliform bacteria may be indicative of that of viruses in soil media near the infiltrative surface receiving wastewater effluent. Concentrations of fecal coliform in percolating soil solution may be conservatively estimated from analysis of extracted soil solids.
Bacillus cereus in free-stall bedding.
Magnusson, M; Svensson, B; Kolstrup, C; Christiansson, A
2007-12-01
To increase the understanding of how different factors affect the bacterial growth in deep sawdust beds for dairy cattle, the microbiological status of Bacillus cereus and coliforms in deep sawdust-bedded free stalls was investigated over two 14-d periods on one farm. High counts of B. cereus and coliforms were found in the entire beds. On average, 4.1 log(10) B. cereus spores, 5.5 log(10) B. cereus, and 6.7 log(10) coliforms per gram of bedding could be found in the upper layers of the sawdust likely to be in contact with the cows' udders. The highest counts of B. cereus spores, B. cereus, and coliforms were found in the bedding before fresh bedding was added, and the lowest immediately afterwards. Different factors of importance for the growth of B. cereus in the bedding material were explored in laboratory tests. These were found to be the type of bedding, pH, and the type and availability of nutrients. Alternative bedding material such as peat and mixtures of peat and sawdust inhibited the bacterial growth of B. cereus. The extent of growth of B. cereus in the sawdust was increased in a dose-dependent manner by the availability of feces. Urine added to different bedding material raised the pH and also led to bacterial growth of B. cereus in the peat. In sawdust, a dry matter content greater than 70% was needed to lower the water activity to 0.95, which is needed to inhibit the growth of B. cereus. In an attempt to reduce the bacterial growth of B. cereus and coliforms in deep sawdust beds on the farm, the effect of giving bedding daily or a full replacement of the beds was studied. The spore count of B. cereus in the back part of the free stalls before fresh bedding was added was 0.9 log units lower in stalls given daily bedding than in stalls given bedding twice weekly. No effect on coliform counts was found. Replacement of the entire sawdust bedding had an effect for a short period, but by 1 to 2 mo after replacement, the counts of B. cereus spores in the beds had increased about 2 log units and were as high as they were before bed replacement. Therefore, free-stall management could, to a limited extent, reduce the content of B. cereus spores in the beds by daily bedding and entire bed replacement.
Coliphages as indicators of enteroviruses.
Stetler, R E
1984-01-01
Coliphages were monitored in conjunction with indicator bacteria and enteroviruses in a drinking-water plant modified to reduce trihalomethane production. Coliphages could be detected in the source water by direct inoculation, and sufficient coliphages were detected in enterovirus concentrates to permit following the coliphage levels through different water treatment processes. The recovery efficiency by different filter types ranged from 1 to 53%. Statistical analysis of the data indicated that enterovirus isolates were better correlated with coliphages than with total coliforms, fecal coliforms, fecal streptococci, or standard plate count organisms. Coliphages were not detected in finished water. PMID:6093694
Sun, Zong-ke; Wu, Rong; Ding, Pei; Xue, Jin-Rong
2006-07-01
To compare between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection. Using inoculated and real water samples to compare the equivalence and false positive rate between two methods. Results demonstrate that enzyme substrate technique shows equivalence with multiple-tube fermentation technique (P = 0.059), false positive rate between the two methods has no statistical difference. It is suggested that enzyme substrate technique can be used as a standard method for water microbiological safety evaluation.
Standridge, J H; Lesar, D J
1977-01-01
The problem of extending the storage time of water samples for fecal coliform analysis was addressed. Included in this report is a literature review of the storage problem. Twenty-eight samples were analyzed in replicate to determine the effect of 24-h storage of water samples at 4 degrees C. A new statistical approach to data analysis, coupled with the concept of practical acceptability, is presented. According to our results, many samples can successfully be stored at 4 degrees C for 24 h. PMID:335972
Vigil, Karen J; Jiang, Zhi-Dong; Chen, Jaclyn J; Palumbo, Kathryn L; Galbadage, Thushara; Brown, Eric L; Yiang, Jing; Koo, Hoonmo; DuPont, Margaret W; Ericsson, Charles; Adachi, Javier A; DuPont, Herbert L
2009-04-01
Bacterial enteropathogens acquired from contaminated food are the principal causes of travelers' diarrhea (TD). We evaluated desserts obtained from popular restaurants in the tourist city of Guadalajara, Mexico, and Houston, Texas, to determine coliform and Escherichia coli contamination levels and presence of diarrheagenic E. coli known to be important in TD. Contamination for all organisms was seen for desserts served in Guadalajara restaurants. Desserts should be considered as potentially risky foods for development of TD among international visitors to developing regions of the world.
Comparison of bacteria populations in clean and recycled sand used for bedding in dairy facilities.
Kristula, M A; Rogers, W; Hogan, J S; Sabo, M
2005-12-01
Bedding samples were collected twice from commercial dairy free-stall facilities that used recycled sand and clean sand in both the summer and winter. Collection began on the day sand was taken from the pile (d 0) and placed in the free stalls, and continued for 5 to 7 additional days. The number of colonies per gram of bedding of gram-negative bacteria, coliforms, Streptococcus spp., and Klebsiella spp. were estimated for each sand sample as well as amounts of dry and organic matter. Clean sand (CS) and recycled sand (RS) had the same bacterial counts when compared at any sampling time. The mean counts of bacterial populations did vary over the course of the study in both CS and RS. There was a significant increase in bacterial counts from d 0 to d 1 for gram-negative bacteria, coliforms, and Streptococcus spp. in both winter and summer. Counts of gram-negative bacteria, coliforms, Klebsiella spp., and Streptococcus spp. did not differ from d 1 to 7 in the winter. Total counts of gram-negative bacteria did not differ from d 1 to 7 in the summer. On d 1 in the summer, coliform counts were lower than at d 5 to 7, and Klebsiella spp. counts were lower than on d 3 to 7. Streptococcus spp. counts were high on d 1 and were constant through d 7 in both winter and summer trials. The number of coliform and Klebsiella spp. in both CS and RS was below the threshold thought to cause mastitis during the sampling times. The number of Streptococcus spp. was high in both CS and RS during the sampling periods. Other management factors need to be identified to decrease the number of Streptococcus spp. in bedding. Recycled sand had a higher organic matter and lower dry matter compared with CS in winter and summer. The results for this study were obtained from multiple herd comparisons, and herd was a significant effect suggesting that different management systems influence the number and types of bacteria in both CS and RS.
Haldar, Lopamudra; Gandhi, D. N.
2016-01-01
Aim: To investigate the effect of oral administration of two Bacillus strains on fecal coliforms, Lactobacillus and Bacillus spp. in rat animal model. Materials and Methods: An in vivo experiment was conducted for 49-day period on 36 adult male albino Wister rats divided equally into to four groups. After 7-day adaptation period, one group (T1) was fed on sterile skim milk along with basal diet for the next 28 days. Second (T2) and (T3) groups received spore biomass of Bacillus coagulans B37 and Bacillus pumilus B9, respectively, suspended in sterilized skim milk at 8-9 log colony-forming units/ml plus basal diet for 28 days, while control group (T4) was supplied with clean water along with basal diet. There was a 14-day post-treatment period. A total of 288 fecal samples (8 fecal collections per rat) were collected at every 7-day interval starting from 0 to 49 days and subjected to the enumeration of the counts of coliforms and lactobacilli and Bacillus spores using respective agar media. In vitro acid and bile tolerance tests on both the strains were performed. Results: The rats those (T2 and T3) received either B. coagulans B37 or B. pumilus B9 spore along with non-fermented skim milk showed decrease (p<0.01) in fecal coliform counts and increase (p<0.05) in both fecal lactobacilli and Bacillus spore counts as compared to the control group (T4) and the group fed only skim milk (T1). In vitro study indicated that both the strains were found to survive at pH 2.0 and 3.0 even up to 3 h and tolerate bile up to 2.0% concentration even after 12 h of exposure. Conclusions: This study revealed that oral administration of either B. coagulans B37 or B. pumilus B9 strains might be useful in reducing coliform counts accompanied by concurrent increase in lactobacilli counts in the intestinal flora in rats. PMID:27536040
Haldar, Lopamudra; Gandhi, D N
2016-07-01
To investigate the effect of oral administration of two Bacillus strains on fecal coliforms, Lactobacillus and Bacillus spp. in rat animal model. An in vivo experiment was conducted for 49-day period on 36 adult male albino Wister rats divided equally into to four groups. After 7-day adaptation period, one group (T1) was fed on sterile skim milk along with basal diet for the next 28 days. Second (T2) and (T3) groups received spore biomass of Bacillus coagulans B37 and Bacillus pumilus B9, respectively, suspended in sterilized skim milk at 8-9 log colony-forming units/ml plus basal diet for 28 days, while control group (T4) was supplied with clean water along with basal diet. There was a 14-day post-treatment period. A total of 288 fecal samples (8 fecal collections per rat) were collected at every 7-day interval starting from 0 to 49 days and subjected to the enumeration of the counts of coliforms and lactobacilli and Bacillus spores using respective agar media. In vitro acid and bile tolerance tests on both the strains were performed. The rats those (T2 and T3) received either B. coagulans B37 or B. pumilus B9 spore along with non-fermented skim milk showed decrease (p<0.01) in fecal coliform counts and increase (p<0.05) in both fecal lactobacilli and Bacillus spore counts as compared to the control group (T4) and the group fed only skim milk (T1). In vitro study indicated that both the strains were found to survive at pH 2.0 and 3.0 even up to 3 h and tolerate bile up to 2.0% concentration even after 12 h of exposure. This study revealed that oral administration of either B. coagulans B37 or B. pumilus B9 strains might be useful in reducing coliform counts accompanied by concurrent increase in lactobacilli counts in the intestinal flora in rats.
NASA Astrophysics Data System (ADS)
Selvam, S.; Antony Ravindran, A.; Venkatramanan, S.; Singaraja, C.
2017-05-01
Heavy metals and microbiological contamination were investigated in groundwater in the industrial and coastal city of Thoothukudi. The main sources of drinking water in this area are water bores which are dug up to the depth of 10-50 m in almost every house. A number of chemical and pharmaceutical industries have been established since past three decades. Effluents from these industries are reportedly being directly discharged onto surrounding land, irrigation fields and surface water bodies forming point and non-point sources of contamination for groundwater in the study area. The study consists of the determination of physico-chemical properties, trace metals, heavy metals and microbiological quality of drinking water. Heavy metals were analysed using Inductively Coupled Plasma Mass Spectrometry and compared with the (WHO in Guidelines for drinking water quality, 2004) standards. The organic contamination was detected in terms of most probable number (MPN) test in order to find out faecal coliforms that were identified through biochemical tests. A comparison of the results of groundwater samples with WHO guidelines reveals that most of the groundwater samples are heavily contaminated with heavy metals like arsenic, selenium, lead, boron, aluminium, iron and vanadium. The selenium level was higher than 0.01 mg/l in 82 % of the study area and the arsenic concentration exceeded 0.01 mg/l in 42 % of the area. The results reveal that heavy metal contamination in the area is mainly due to the discharge of effluents from copper industries, alkali chemical industry, fertiliser industry, thermal power plant and sea food industries. The results showed that there are pollutions for the groundwater, and the total Coliform means values ranged from 0.6-145 MPN ml-1, faecal Coliform ranged from 2.2-143 MPN ml-1, Escherichia coli ranged from 0.9 to 40 MPN ml-1 and faecal streptococci ranged from 10-9.20 × 102 CFU ml-1. The coastal regions are highly contaminated with total coliform bacteria, faecal coliform bacteria and E. coli. This might be due to the mixing of sewage from Thoothukudi town through the Buckle channel and fishing activity.
Avila-Vega, Dulce E; Alvarez-Mayorga, Beatriz; Arvizu-Medrano, Sofía M; Pacheco-Aguilar, Ramiro; Martínez-Peniche, Ramón; Hernández-Iturriaga, Montserrat
2014-11-01
The aim of this study was to generate information regarding the microbiological profile, including Salmonella and Listeria monocytogenes incidence, of hydroponically grown bell peppers and materials associated with their production in greenhouses located in Mexico. Samples of coconut fiber (24), knives (30), drippers (20), conveyor belts (161), pepper transportation wagons (30), air (178), water (16), nutrient solution for plant irrigation (78), and bell pepper fruits (528) were collected during one cycle of production (2009 to 2010) for the quantification of microbial indicators (aerobic plate counts [APC], molds, coliforms, and Escherichia coli) and the detection of Salmonella and L. monocytogenes. With regard to surfaces (conveyor belts and wagons) and utensils (knives and drippers), the APC, coliform, and mold counts ranged from 3.0 to 6.0, from 1.4 to 6.3, and from 3.6 to 5.2 log CFU/100 cm(2) or per utensil, respectively. The air in the greenhouse contained low median levels of APC (1.2 to 1.4 log CFU/100 liters) and molds (2.2 to 2.5 log CFU/100 liters). The median content of APC and coliforms in water were 0.5 log CFU/ml and 0.3 log MPN/100 ml, respectively. The median content of coliforms in nutrient solution ranged from 1.8 to 2.4 log MPN/100 ml, and E. coli was detected in 18 samples (range, <0.3 to 1.2 log MPN/100 ml). On bell pepper analyzed during the study, populations (median) of APC, coliforms, and molds were 5.4, 3.6, and 5.8 log CFU per fruit, respectively; E. coli was detected in 5.1% of the samples (range, 0.23 to 1.4 log MPN per fruit). Salmonella was isolated from only one sample (1.6%) of conveyor belt located at the packing area and in four bell pepper samples (3%). L. monocytogenes was not detected. This information could help producers to establish effective control measures to prevent the presence of foodborne pathogens in bell peppers based on a scientific approach.
Paduch, Jan-Hendrik; Mohr, Elmar; Krömker, Volker
2013-05-01
Several mastitis-causing pathogens are able to colonize the bovine teat canal. The objective of this study was to investigate the association between the treatment of sawdust bedding with a commercial alkaline conditioner and the bacterial counts on teat skin and in the teat canal. The study used a crossover design. Ten lactating Holstein cows that were free of udder infections and mastitis were included in the study. The animals were bedded on either untreated sawdust or sawdust that had been treated with a hydrated lime-based conditioner. Once a day, fresh bedding material was added. After 3 weeks, the bedding material was removed from the cubicles, fresh bedding material was provided, and the cows were rotated between the two bedding material groups. Teat skin and teat canals were sampled using the wet and dry swab technique after weeks 1, 2, 3, 4, 5 and 6. Staphylococcus aureus, Streptococcus uberis, Escherichia coli and other coliform bacteria were detected in the resulting agar plate cultures. The treatment of the bedding material was associated with the teat skin bacterial counts of Str. uberis, Esch. coli and other coliform bacteria. An association was also found between the bedding material and the teat canal bacterial counts of coliform bacteria other than Esch. coli. For Staph. aureus, no associations with the bedding material were found. In general, the addition of a hydrated lime-based conditioner to sawdust reduces the population sizes of environmental pathogens on teat skin and in teat canals.
Alqahtani, Jobran M; Asaad, Ahmed M; Ahmed, Essam M; Qureshi, Mohamed A
2015-01-01
The aim was to investigate the bacteriological quality of drinking water, and explore the factors involved in the knowledge of the public about the quality of drinking water in Najran region, Saudi Arabia. A cross-sectional descriptive study. A total of 160 water samples were collected. Total coliforms, fecal coliform, and fecal streptococci were counted using Most Probable Number method. The bacterial genes lacZ and uidA specific to total coliforms and Escherichia coli, respectively, were detected using multiplex polymerase chain reaction. An interview was conducted with 1200 residents using a questionnaire. Total coliforms were detected in 8 (20%) of 40 samples from wells, 13 (32.5%) of 40 samples from tankers, and 55 (68.8%) of 80 samples from roof tanks. Twenty (25%) and 8 (10%) samples from roof tanks were positive for E. coli and Streptococcus faecalis, respectively. Of the 1200 residents participating in the study, 10%, 45.5%, and 44.5% claimed that they depended on municipal water, bottled water, and well water, respectively. The majority (95.5%) reported the use of roof water tanks as a source of water supply in their homes. Most people (80%) believed that drinking water transmitted diseases. However, only 25% of them participated in educational programs on the effect of polluted water on health. Our results could help health authorities consider a proper regular monitoring program and a sustainable continuous assessment of the quality of well water. In addition, this study highlights the importance of the awareness and educational programs for residents on the effect of polluted water on public health.
McGinnis, Shannon; Spencer, Susan K.; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark A.; McCarthy, David; Murphy, Heather
2018-01-01
Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May–July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs.
McGinnis, Shannon; Spencer, Susan; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark; McCarthy, David T; Murphy, Heather M
2018-07-15
Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May-July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs. Copyright © 2018 Elsevier B.V. All rights reserved.
Kang, D H; Koohmaraie, M; Siragusa, G R
2001-02-01
Commercially produced, irregularly sized (range, 100 to 400 cm2), uninoculated beef trim was treated by a previously optimized multihurdle antimicrobial process under spray system or hot air gun with set-up speed (1 cm/s): W (water wash at 65 psi for five passes) + HW (82 degrees C water at 30 psi for three passes) + HA (510 degrees C air for five passes) + L (2% [vol/vol] room temperature lactic acid wash at 30 psi for three passes). After treatment, the trim was finely ground, vacuum packaged, and stored at 4 degrees C for up to 20 days. At regular intervals (0, 5, 10, 15, and 20 days of storage at 4 degrees C), the ground beef was analyzed to measure mesophilic aerobic bacteria (APC), coliforms, psychrotrophic bacteria (PCT), and presumptive lactic acid bacteria (PLAB) and compared with the untreated control. The numbers of APC, coliforms, PCT, and PLAB were reduced to nearly nondetectable levels immediately after treatment, with significant differences compared with the control (P < 0.05), then started to increase after 5 to 10 days of storage at 4 degrees C. After 20 days, microbial populations of treated ground beef were significantly lower than those of nontreated ground beef for the numbers of APC, coliforms, PCT, and PLAB (P < 0.05), with differences of 1.2, 2.4, 1.6, and 1.6 log CFU/g, respectively. Based on microbial reduction and quality aspects, the multihurdle antimicrobial process was identified as an effective intervention to reduce coliforms on beef trim.
Abu Amr, S S; Yassin, M M
2008-11-01
To assess total and faecal coliform contamination in water wells and distribution networks over the past 7 years, and their association with human health in Khan Yunis Governorate, Gaza Strip. Historical data and interview questionnaire. Data were obtained from the Palestinian Ministry of Health on total and faecal coliform contamination in water wells and distribution networks, and on the incidence of water-related diseases in Khan Yunis Governorate. An interview questionnaire was conducted with 210 residents of Khan Yunis Governorate. Total and faecal coliform contamination exceeded the World Health Organization's limit for water wells and networks. However, the contamination percentages were higher in networks than in wells. Diarrhoeal diseases were strongly correlated with faecal coliform contamination in water networks (r=0.98). This is consistent with the finding that diarrhoeal diseases were the most common self-reported diseases among the interviewees. Such diseases were more prevalent among subjects who drank municipal water than subjects who drank desalinated or home-filtered water (odds ratio=2.03). Intermittent water supply, insufficient chlorination and sewage flooding seem to be associated with self-reported diseases. Residents in the Gaza Strip have a good level of knowledge about drinking water contamination, and this is reflected in good practice. Water quality has deteriorated in the Gaza Strip, and this may contribute to the prevalence of water-related diseases. Self-reported diseases among interviewees in Khan Yunis Governorate were associated with source of drinking water, intermittent water supply, insufficient chlorination, sewage flooding and age of water networks.
Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.
Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup
2014-11-01
Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.
Microbial contamination of drinking water in Pakistan--a review.
Nabeela, Farhat; Azizullah, Azizullah; Bibi, Roqaia; Uzma, Syeda; Murad, Waheed; Shakir, Shakirullah Khan; Ullah, Waheed; Qasim, Muhammad; Häder, Donat-Peter
2014-12-01
Water pollution with pathogenic microorganisms is one of the serious threats to human health, particularly in developing countries. The main objective of this article is to highlight microbial contamination of drinking water, the major factors responsible for microbial contamination, and the resulting health problems in Pakistan. Furthermore, this study will be helpful for researchers and administrative agencies to initiate relevant studies and develop new policies to protect further deterioration of water supply with pathogenic microbes and ensure clean and safe drinking water to the public in Pakistan. In Pakistan, water at the source, in the distribution network, and at the consumer tap is heavily polluted with coliforms and fecal coliforms all over the country. An overview of more than 7,000 water samples reviewed here reveals that an average of over 71 and 58 % samples in the country was contaminated with total coliforms and fecal coliforms, respectively. Drinking water contamination accounts for 20 to 40 % of all diseases in the country, which causes national income losses of Rs 25-58 billion annually (US$0.25-0.58 billion, approximately 0.6-1.44 % of the country's GDP). Improper disposal of industrial and municipal wastes is the most important factor responsible for water pollution in the country followed by cross-contamination due to old and leaking pipes and lack of water filtration and disinfection facilities. There is an urgent need for emergency steps to stop further deterioration of water quality and improve the existing water quality so as to protect the public from widespread waterborne diseases.
Sivaraman, G K; Visnuvinayagam, S; Jha, Ashish Kumar; Renuka, V; Remya, S; Vanik, Deesha
2016-07-01
The present study was carried out to assess the microbial quality of fish processing industries effluent at Bhidia bar-mouth, Veraval, Gujarat during April, 2012 to March 2013. The total viable bacterial count (TVBC), total Enterobacteriaceae count, E. coli count (EC), Staphylococcus aureus and Fecal Streptococcal count in effluent ranged from 3.0 x 10(-1) to 6.8 x 10(6), 9.0 x 10(1) to 2.9 x 10(4), 0 to 0. 5 x 10(4), 0 to 0. 4 x 102 and 0.3 x 10(1) to 0. 1 x 10(4) cfu.(-1)respectively. Significantly higher load of TEC, E. coli, S.aureus, Fecal Streptococci, Total coliforms and Fecal coliforms were higher during summer whereas, TVBC was higher in the month of Sept.-Oct. Furthermore, the total coliform and fecal coliform counts were found to be higher with 1400+ /100 ml MPN value throughout the year of the study, except in the month of August. Overall occurrence of pathogenic strains of E. coli, S. aureus and Fecal streptococci were 41.67%, 25.00% and 66.67% respectively during this period. The antibiogram of the isolated E. coli isolates show that almost 50% were resistant to Cefazidime/Clavulanic acid (CAC), Amoxyclav (AMC), Ciprofloxacin (CIF) and Ampicillin (AMP). The present study indicated that the effluent of fish processing industry was heavily contaminated with E. coli, S. aureus and Fecal Streptococci which confirmed improper treatment of fish processing effluent. Moreover, the precedence of antibiotic resistant E. coli may pose threat to public health safety.
Potential sources of microbial contamination in unpasteurized apple cider.
Garcia, Luis; Henderson, John; Fabri, Martha; Oke, Moustapha
2006-01-01
A study was conducted to identify possible sources of microbial contamination and to assess the effect of good cleaning and sanitation practices on the microbial quality and safety of unpasteurized apple cider. Raw unwashed apples, washed apples, cleaning water, fresh cider, and finished cider samples were collected from five Ontario producers over 4 months and microbiologically tested. Total coliforms were found in 31, 71 and 38% of the unwashed apple, water, and washed apple samples, respectively. Escherichia coli was found in 40% of the water samples from one producer alone. The washing step was identified as a potential source of contamination, possibly due to water in the dump tanks seldom being refreshed, and because scrubbers, spray nozzles, and conveyors were not properly cleaned and sanitized. Higher total coliform counts (P < 0.0001) and prevalence (P < 0.0001) in fresh cider compared with those in unwashed apples and washed apples indicated considerable microbial buildup along the process, possibly explained by the lack of appropriate equipment sanitation procedures. Results showed that producers who had better sanitary practices in place had lower (P < 0.001) total coliform prevalence than the rest of the producers. Overall results show that good sanitation procedures are associated with improved microbial quality of fresh cider in terms of total coliforms and that operators who pasteurize and/or UV treat their product should still be required to have a sound good manufacturing practices program in place to prevent recontamination. Cryptosporidium parvum, an important pathogen for this industry, was found in different sample types, including washed apples, water, and fresh and finished cider.
Weppelmann, Thomas A; Alam, Meer T; Widmer, Jocelyn; Morrissey, David; Rashid, Mohammed H; De Rochars, Valery M Beau; Morris, J Glenn; Ali, Afsar; Johnson, Judith A
2014-12-01
In 2010, a magnitude 7.0 earthquake struck Haiti, severely damaging the drinking and wastewater infrastructure and leaving millions homeless. Compounding this problem, the introduction of Vibrio cholerae resulted in a massive cholera outbreak that infected over 700,000 people and threatened the safety of Haiti's drinking water. To mitigate this public health crisis, non-government organizations installed thousands of wells to provide communities with safe drinking water. However, despite increased access, Haiti currently lacks the monitoring capacity to assure the microbial safety of any of its water resources. For these reasons, this study was designed to assess the feasibility of using a simple, low-cost method to detect indicators of fecal contamination of drinking water that could be implemented at the community level. Water samples from 358 sources of drinking water in the Léogâne flood basin were screened with a commercially available hydrogen sulfide test and a standard membrane method for the enumeration of thermotolerant coliforms. When compared with the gold standard method, the hydrogen sulfide test had a sensitivity of 65 % and a specificity of 93 %. While the sensitivity of the assay increased at higher fecal coliform concentrations, it never exceeded 88 %, even with fecal coliform concentrations greater than 100 colony-forming units per 100 ml. While its simplicity makes the hydrogen sulfide test attractive for assessing water quality in low-resource settings, the low sensitivity raises concerns about its use as the sole indicator of the presence or absence of fecal coliforms in individual or community water sources.
Jones, D R; Anderson, K E; Guard, J Y
2012-05-01
There is a desire by US consumers for eggs produced by hens in alternative production systems. As the retail shell-egg market offers these products to accommodate consumer demands, additional information is needed to ensure processing methodologies result in safe eggs from all egg sources. A study was conducted to determine if there were differences in the prevalence of coliforms, Salmonella, Listeria, and Campylobacter on and within eggs and in the environment of a sister flock of conventional cage and free-range laying hens. Microbial sampling occurred approximately every 6 wk between 20 and 79 wk of age. A random sampling of typical coliform colonies produced 371 viable isolates for biochemical identification. Twenty-nine genera or species of bacteria were identified. There was a significantly greater (P < 0.0001) prevalence of Campylobacter in the free-range nest box swabs compared with that in the free-range grass and conventional cage swab samples (number of positives: 8 nest box, 1 grass, 0 cage). Seven isolates of Listeria innocua were detected with no significant difference in prevalence between the treatments. Isolates were associated with eggshells (2 free-range floor, 1 cage) and the free-range environment (2 nest box, 2 grass). There were 21 Salmonella isolates detected between all sample locations, with no significant difference in the prevalence of Salmonella detection between the treatments. Additional studies are needed to fully understand the effect of alternative production methods on the prevalence of pathogens and coliforms associated with nest-run eggs and the production environment.
Shelton, D R; Pachepsky, Y A; Kiefer, L A; Blaustein, R A; McCarty, G W; Dao, T H
2014-08-01
As sediments increasingly become recognized as reservoirs of indicator and pathogen microorganisms, an understanding of the persistence of indicator organisms becomes important for assessment and predictions of microbial water quality. The objective of this work was to observe the response of water column and sediment coliform populations to the change in nutrient concentrations in the water column. Survival experiments were conducted in flow-through chambers containing sandy sediments. Bovine feces were collected fresh and introduced into sediment. Sixteen days later, the same fecal material was autoclaved and diluted to provide three levels - 1×, 0.5×, and 0.1× of nutrient concentrations - spike in water column. Total coliforms, Escherichia coli, and total aerobic heterotrophic bacterial concentrations were monitored in water and sediment. Bacteria responded to the nutrient spike with initial growth both in the water column and in sediment. The response of bacterial concentrations in water column was nonlinear, with no significant changes at 0.1 and .5× spikes, but a substantial change at 1× spike. Bacteria in sediment responded to the spikes at all added nutrient levels. Coliform inactivation rates both in sediment and in water after the initial growth occurred, were not significantly different from the inactivation rates before spike. These results indicate that introduction of nutrients into the water column results in nonlinear response of E. coli concentrations both in water and in sediments, followed by the inactivation with the same rate as before introduction of nutrients. Published by Elsevier Ltd.
Weppelmann, Thomas A.; Alam, Meer T.; Widmer, Jocelyn; Morrissey, David; Rashid, Mohammed H.; Beau De Rochars, Valery M.; Morris, J. Glenn; Ali, Afsar; Johnson, Judith A.
2014-01-01
In 2010 a magnitude 7.0 earthquake struck Haiti, severely damaging the drinking and waste water infrastructure and leaving millions homeless. Compounding this problem, the introduction of Vibrio cholera resulted in a massive cholera outbreak that infected over 700,000 people and threatened the safety of Haiti’s drinking water. To mitigate this public health crisis, non-government organizations installed thousands of wells to provide communities with safe drinking water. However, despite increased access, Haiti currently lacks the monitoring capacity to assure the microbial safety of any of its water resources. For these reasons, this study was designed to assess the feasibility of using a simple, low cost method to detect indicators of fecal contamination of drinking water that could be implemented at the community level. Water samples from 358 sources of drinking water in the Léogâne flood basin were screened with a commercially available hydrogen sulfide test and a standard membrane method for the enumeration of thermotolerant coliforms. When compared with the gold standard method, the hydrogen sulfide test had a sensitivity of 65% and a specificity of 93%. While the sensitivity of the assay increased at higher fecal coliform concentrations, it never exceeded 88%, even with fecal coliform concentrations greater than 100 colony forming units per 100 milliliters. While its simplicity makes the hydrogen sulfide test attractive for assessing water quality in low resource settings, the low sensitivity raises concerns about its use as the sole indicator of the presence or absence of fecal coliforms in individual or community water sources. PMID:25182685
NASA Astrophysics Data System (ADS)
Desmiarti, Reni; Hazmi, Ariadi; Martynis, Munas; Sutopo, Ulung Muhammad; Li, Fusheng
2018-02-01
Pathogenic bacteria, such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC), were removed from groundwater by inductively coupled plasma system treatment in continuous flow experiments. The objective of this study is to investigate the effect of flowrate and frequency on the behavior of microorganisms in drinking water treatment using inductively coupled plasma system (ICPS). The results showed that after 120 minutes of ICPS treatment, the removal efficiency with respect to TC, FC and OC decreased with increasing flowrate. The removal efficiency of FC was achieved at 100% in all runs. Compared to FC, the removal efficiencies with respect to TC and FC were lower than those with respect to TC and OC in the following order: FC >OC> TC. The disinfection yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 8.08±0.46 to 10.54±0.19 W/cm2. The results in the present work can be used to design a new technology for drinking water treatment to remove all pathogenic bacteria without using hazardous chemicals.
Evaluation of the bacteriological quality of ice cream sold at San Jose, Costa Rica.
Windrantz, P; Arias, M L
2000-09-01
The presence of total and fecal coliforms, E. coli, Listeria sp and Salmonella sp. was evaluated in 65 samples of both commercial and homemade ice cream. 37.1% of homemade ice cream and 20% of commercial ice cream did not fulfill the international standard for total coliforms. At the same time 82.9% of home made samples and 56.7% of commercial ones presented fecal coliforms. E. coli was found in 51.4% of home made samples and 26.7% of commercial ones. Sixteen Listeria sp. isolates were obtained, 50% corresponded to Listeria monocytogenes and 50% to L. innocua. The overall presence of L. monocytogenes in ice cream samples was of 12.3% and it was isolated in all cases, from homemade ice cream samples. Salmonella was not isolated from the samples analyzed. Although the results obtained show an important improvement in the quality of ice cream, compared with a previous work done also in Costa Rica, further efforts shall be done, in order to offer safe products to consumers.
Bacteria associated with granular activated carbon particles in drinking water.
Camper, A K; LeChevallier, M W; Broadaway, S C; McFeters, G A
1986-01-01
A sampling protocol was developed to examine particles released from granular activated carbon filter beds. A gauze filter/Swinnex procedure was used to collect carbon fines from 201 granular activated carbon-treated drinking water samples over 12 months. Application of a homogenization procedure (developed previously) indicated that 41.4% of the water samples had heterotrophic plate count bacteria attached to carbon particles. With the enumeration procedures described, heterotrophic plate count bacteria were recovered at an average rate of 8.6 times higher than by conventional analyses. Over 17% of the samples contained carbon particles colonized with coliform bacteria as enumerated with modified most-probable-number and membrane filter techniques. In some instances coliform recoveries were 122 to 1,194 times higher than by standard procedures. Nearly 28% of the coliforms attached to these particles in drinking water exhibited the fecal biotype. Scanning electron micrographs of carbon fines from treated drinking water showed microcolonies of bacteria on particle surfaces. These data indicate that bacteria attached to carbon fines may be an important mechanism by which microorganisms penetrate treatment barriers and enter potable water supplies. PMID:3767356
Microbioligical Hazard Contamination in Fermented Vegetables Sold in Local Markets in Cambodia.
Chrun, Rithy; Hosotani, Yukie; Kawasaki, Susumu; Inatsu, Yasuhiro
2017-01-01
Fermented vegetables are common part of Cambodian diet. The food safety status for these foods has not been investigated. This study was conducted to evaluate the microbiological hazards that contaminated fermented vegetables. A total of 68 samples of fermented vegetables were purchased randomly from five wet markets in Phnom Penh. The conventional culture methods for microbiological analysis were used. Coliform bacteria (Escherichia coli, Cronobactersakazakii, and Enterobacter spp.), opportunistic non-Entrobacteriaceae, Enterococcus spp., Staphylococcus spp., and Listeria spp. were found in these fermented foods. The highest contamination rate of Enterococcus spp. was 34% of total fermented vegetable samples, followed by Bacillus spp. coliform bacteria and E. coli (31%, 24% and 10%, respectively). The potential foodborne pathogen, C. sakazakii, was identified in one sample. Fermented mixed vegetables showed higher contamination rate of coliform bacteria (50%) than fermented single-type vegetables (13%). The results showed that fermented vegetables sold in wet market are poor in hygiene. The stage in the processing chain where contamination occurred should be identified and basic sanitary practice should be enforced to improve the food safety of fermented vegetables in Cambodia.
Tobin, R S; Lomax, P; Kushner, D J
1980-01-01
Nine different brands of membrane filter were compared in the membrane filtration (MF) method, and those with the highest yields were compared against the most-probable-number (MPN) multiple-tube method for total coliform enumeration in simulated sewage-contaminated tap water. The water was chlorinated for 30 min to subject the organisms to stresses similar to those encountered during treatment and distribution of drinking water. Significant differences were observed among membranes in four of the six experiments, with two- to four-times-higher recoveries between the membranes at each extreme of recovery. When results from the membranes with the highest total coliform recovery rate were compared with the MPN results, the MF results were found significantly higher in one experiment and equivalent to the MPN results in the other five experiments. A comparison was made of the species enumerated by these methods; in general the two methods enumerated a similar spectrum of organisms, with some indication that the MF method was subject to greater interference by Aeromonas. PMID:7469407
Removal of contaminants and pathogens from secondary effluents using intermittent sand filters.
Bali, Mahmoud; Gueddari, Moncef; Boukchina, Rachid
2011-01-01
Intermittent infiltration percolation of wastewater through unsaturated sand bed is an extensive treatment technique aimed at eliminating organic matter, oxidizing ammonium and removing pathogens. The main purpose of this study was to determine the depuration efficiencies of a sand filter to remove contaminants from secondary wastewater effluents. Elimination of pathogenic bacteria (total and faecal coliforms, streptococci) and their relationship with the filter depth were investigated. Results showed a high capacity of infiltration percolation process to treat secondary effluents. Total elimination of suspended solids was obtained. Mean removal rate of BOD(5) and COD was more than 97 and more than 81%, respectively. Other water quality parameters such as NH(4)-N, TKN and PO(4)-P showed significant reduction except NO(3)-N which increased significantly in the filtered water. Efficiency of pathogenic bacteria removal was shown to mainly depend on the filter depth. Average reductions of 2.35 log total coliforms, 2.47 log faecal coliforms and 2.11 log faecal streptococci were obtained. The experimental study has shown the influence of the temperature on the output purification of infiltration percolation process.
Occurrence and distribution of microbiological indicators in groundwater and stream water
Francy, D.S.; Helsel, D.R.; Nally, R.A.
2000-01-01
A total of 136 stream water and 143 groundwater samples collected in five important hydrologic systems of the United States were analyzed for microbiological indicators to test monitoring concepts in a nationally consistent program. Total coliforms were found in 99%, Escherichia coli in 97%, and Clostridium perfringens in 73% of stream water samples analyzed for each bacterium. Total coliforms were found in 20%, E. coli in less than 1%, and C. perfringens in none of the groundwater samples analyzed for each bacterium. Although coliphage analyses were performed on many of the samples, contamination in the laboratory and problems discerning discrete plaques precluded quantification. Land use was found to have the most significant effect on concentrations of bacterial indicators in stream water. Presence of septic systems on the property near the sampling site and well depth were found to be related to detection of coliforms in groundwater, although these relationships were not statistically significant. A greater diversity of sites, more detailed information about some factors, and a larger dataset may provide further insight to factors that affect microbiological indicators.
Giannuzzi, L.; Carvajal, G.; Corradini, M. G.; Araujo Andrade, C.; Echenique, R.; Andrinolo, D.
2012-01-01
Water samples were collected during 3 years (2004–2007) at three sampling sites in the Rio de la Plata estuary. Thirteen biological, physical, and chemical parameters were determined on the water samples. The presence of microcystin-LR in the reservoir samples, and also in domestic water samples, was confirmed and quantified. Microcystin-LR concentration ranged between 0.02 and 8.6 μg.L−1. Principal components analysis was used to identify the factors promoting cyanobacteria growth. The proliferation of cyanobacteria was accompanied by the presence of high total and fecal coliforms bacteria (>1500 MNP/100 mL), temperature ≥25°C, and total phosphorus content ≥1.24 mg·L−1. The observed fluctuating patterns of Microcystis aeruginosa, total coliforms, and Microcystin-LR were also described by probabilistic models based on the log-normal and extreme value distributions. The sampling sites were compared in terms of the distribution parameters and the probability of observing high concentrations for Microcystis aeruginosa, total coliforms, and microcystin-LR concentration. PMID:22523486
Duggan, J; Bates, M P; Phillips, C A
2001-06-01
The use of poultry waste as a fertiliser on arable land is an accepted method of waste treatment. However, run-off from such practices may result in contamination of the watercourse by human pathogens. In this study the effectiveness of using constructed wetlands as an alternative treatment for poultry manure waste was evaluated. Enumeration of Campylobacter spp., Escherichia coli, total coliforms and total aerobes were carried out on influent and effluent samples from reed beds loaded with poultry waste. For both sequential loading and continuous loading there was a statistically significant mean log reduction of 3.56 and 4.25 for E. coli, 3.2 and 3.88 for coliforms, 3.85 and 4.2 for total aerobic counts and 3.13 and 2.96 for Campylobacter spp., respectively. This method, which has been previously recognised as cost-effective and environmentally acceptable, provides an efficient method for reducing numbers of these bacteria in poultry waste and therefore an effective alternative treatment for such waste or waters containing run off from land previously spread with poultry manure.
NASA Astrophysics Data System (ADS)
Soo, Chen-Lin; Ling, Teck-Yee; Lee, Nyanti; Apun, Kasing
2016-03-01
The concentrations of nutrients (nitrogen and phosphorus), total metals, and fecal coliform (FC) coupling with chlorophyll- a (chl- a), 5-day biochemical oxygen demand (BOD5) and other general environmental parameters were evaluated at the sub-surface and near-bottom water columns of 13 stations in the Sibu Laut River during low and high slack waters. The results indicated that inorganic nitrogen (mainly nitrate) was the primary form of nitrogen whereas organic phosphorus was the major form of phosphorus. The abundance of total heavy metals in Sibu Laut River and its tributaries was in the order of Pb < Cu < Zn < Cd. Fecal coliform concentration was relatively low along Sibu Laut River. The shrimp farm effluents contributed a substantial amount of chl- a, BOD5, nutrients, and FC to the receiving creek except for total metals. Nevertheless, the influence was merely noticeable in the intake creek and amended rapidly along Selang Sibu River and brought minimal effects on the Sibu Laut River. Besides, the domestic sewage effluents from villages nearby also contributed a substantial amount of pollutants.
Transport of free and particulate-associated bacteria in karst
Mahler, B.J.; Personne, J.-C.; Lods, G.F.; Drogue, C.
2000-01-01
Karst aquifers, because of their unique hydrogeologic characteristics, are extremely susceptible to contamination by pathogens. Here we present the results of an investigation of contamination of a karst aquifer by fecal indicator bacteria. Two wells intercepting zones with contrasting effective hydraulic conductivities, as determined by pump test, were monitored both during the dry season and in response to a rain event. Samples were also collected from the adjacent ephemeral surface Stream, which is known to be impacted by an upstream wastewater treatment plant after rainfall. Whole water and suspended sediment samples were analyzed for fecal coliforms and enterococci. During the dry season, pumping over a 2-day period resulted in increases in concentrations of fecal coliforms to greater than 10,000 CFU/100 ml in the high-conductivity well; enterococci and total suspended solids also increased, to a lesser degree. Toward the end of the pumping period, as much as 50% of the fecal coliforms were associated with suspended sediment. Irrigation of an up-gradient pine plantation with primary-treated wastewater is the probable source of the bacterial contamination. Sampling after a rain event revealed the strong influence of water quality of the adjacent Terrieu Creek on the ground water. Bacterial concentrations in the wells showed a rapid response to increased concentrations in the surface water, with fecal coliform concentrations in ground water ultimately reaching 60,000 CFU/100 ml. Up to 100% of the bacteria in the ground water was associated with suspended sediment at various times. The results of this investigation are evidence of the strong influence of surface water on ground water in karst terrain, including that of irrigation water. The large proportion of bacteria associated with particulates in the ground Water has important implications for public health, as bacteria associated with particulates may be more persistent and more difficult to inactivate. The high bacterial concentrations found in both wells, despite the difference in hydraulic conductivity, demonstrates the difficulty of predicting vulnerability of individual wells to bacterial contamination in karst. The extreme temporal variability in bacterial concentrations underscores the importance of event-based monitoring of the bacterial quality of public water supplies in karst. (C) 2000 Elsevier Science B.V.Karst aquifers, because of their unique hydrogeologic characteristics, are extremely susceptible to contamination by pathogens. Here we present the results of an investigation of contamination of a karst aquifer by fecal indicator bacteria. Two wells intercepting zones with contrasting effective hydraulic conductivities, as determined by pump test, were monitored both during the dry season and in response to a rain event. Samples were also collected from the adjacent ephemeral surface stream, which is known to be impacted by an upstream wastewater treatment plant after rainfall. Whole water and suspended sediment samples were analyzed for fecal coliforms and enterococci. During the dry season, pumping over a 2-day period resulted in increases in concentrations of fecal coliforms to greater than 10,000 CFU/100 ml in the high-conductivity well; enterococci and total suspended solids also increased, to a lesser degree. Toward the end of the pumping period, as much as 50% of the fecal coliforms were associated with suspended sediment. Irrigation of an up-gradient pine plantation with primary-treated wastewater is the probable source of the bacterial contamination. Sampling after a rain event revealed the strong influence of water quality of the adjacent Terrieu Creek on the ground water. Bacterial concentrations in the wells showed a rapid response to increased concentrations in the surface water, with fecal coliform concentrations in ground water ultimately reaching 60,000 CFU/100 ml. Up to 100% of the bacteria in the ground water was associated with suspended
Method and automated apparatus for detecting coliform organisms
NASA Technical Reports Server (NTRS)
Dill, W. P.; Taylor, R. E.; Jeffers, E. L. (Inventor)
1980-01-01
Method and automated apparatus are disclosed for determining the time of detection of metabolically produced hydrogen by coliform bacteria cultured in an electroanalytical cell from the time the cell is inoculated with the bacteria. The detection time data provides bacteria concentration values. The apparatus is sequenced and controlled by a digital computer to discharge a spent sample, clean and sterilize the culture cell, provide a bacteria nutrient into the cell, control the temperature of the nutrient, inoculate the nutrient with a bacteria sample, measures the electrical potential difference produced by the cell, and measures the time of detection from inoculation.
Bacteriological quality of drinks from vending machines.
Hunter, P. R.; Burge, S. H.
1986-01-01
A survey on the bacteriological quality of both drinking water and flavoured drinks from coin-operated vending machines is reported. Forty-four per cent of 25 drinking water samples examined contained coliforms and 84% had viable counts of greater than 1000 organisms ml at 30 degrees C. Thirty-one flavoured drinks were examined; 6% contained coliforms and 39% had total counts greater than 1000 organisms ml. It is suggested that the D.H.S.S. code of practice on coin-operated vending machines is not being followed. It is also suggested that drinking water alone should not be dispensed from such machines. PMID:3794325
NASA Astrophysics Data System (ADS)
Karthe, Daniel; Lin, Pei-Ying; Westphal, Katja
2017-09-01
The Holtemme is a small headwater stream in North Germany's Elbe River Basin. According to German and European legislation, hygienic monitoring is not mandatory for such water bodies which are neither drinking water sources nor categorized as bathing waters. Consequently, relatively little is known about the occurrence of-potentially pathogenic-bacteria and viruses in Germany's streams and rivers. The Holtemme was selected for a case study because it is relatively well monitored for both chemical water quality and aquatic ecology, but not for hygiene. Originating in the mountains of Harz Nature Park, the 47 km long Holtemme is characterized by a strong longitudinal gradient in chemical water quality, which is related to different land uses and the influx of treated wastewater from two urban areas (Wernigerode and Halberstadt). Waste water loads received by the Holtemme are comparatively high when compared to similarly small streams. In 2015, total coliform concentrations between more than 200 and 77,010 bacteria per 100 mL, and fecal coliform concentrations between 5 and 24,060 bacteria per 100 mL were observed in the Holtemme's main channel. The highest concentrations were typically found below the outlets of the two wastewater treatment plants. The treated wastewater contained total and fecal coliform concentrations of up to 200,500 and 83,100 per 100 mL, respectively; however, there were significant temporal variations. While the observed concentrations are unproblematic from a legal perspective (because no maximum permissible limits are defined for streams in Germany), they would exceed the tolerable limits for bathing waters in the EU, indicating moderate to critical pollution limits.
Bonjoch, X; García-Aljaro, C; Blanch, A R
2011-07-01
To assess the persistence and diversity of faecal bacterial populations (faecal coliforms and enterococci) that have recently been included in microbial source tracking (MST) predictive models. The analysed bacterial populations included members of the enterococci group (ENT) [Enterococcus faecium (FM), Enterococcus faecalis (FS) and Enterococcus hirae (HIR)] and the faecal coliform group (FC) [diverse Escherichia coli phenotypes (ECP) and cellobiose-negative faecal coliforms (CNFC)]. The inactivation of these distinct groups was monitored over time on-site in river by biochemical fingerprinting, and diversity indices were calculated. Among the different analysed species belonging to the ENT group, HIR persisted longer and was able to replicate in the environment at a higher rate. On the other hand, ECP and NCFC showed a similar persistence throughout the different seasons. The diversity index (Di) for FC increased substantially in the summer after 96 h to a maximum value of 0·96. On the other hand, the Di for ENT diminished over the same period to a value of 0·86, suggesting a different persistence for the different species integrating this group. The persistence of ECP, CNFC, FM and FS in the aquatic environment is high, particularly for the members of the FC and in the summer season. On the contrary, HIR is able to replicate in the environment at a high rate even in winter, and therefore, its inclusion in MST predictive models is discouraged. ECP, CNFC, FMFS and HIR have been proposed as additional variables in MST predictive models. However, the different persistence of HIR compared with the other variables should be taken into account for the development of such models. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.
Minimally processed vegetable salads: microbial quality evaluation.
Fröder, Hans; Martins, Cecília Geraldes; De Souza, Katia Leani Oliveira; Landgraf, Mariza; Franco, Bernadette D G M; Destro, Maria Teresa
2007-05-01
The increasing demand for fresh fruits and vegetables and for convenience foods is causing an expansion of the market share for minimally processed vegetables. Among the more common pathogenic microorganisms that can be transmitted to humans by these products are Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella. The aim of this study was to evaluate the microbial quality of a selection of minimally processed vegetables. A total of 181 samples of minimally processed leafy salads were collected from retailers in the city of Sao Paulo, Brazil. Counts of total coliforms, fecal coliforms, Enterobacteriaceae, psychrotrophic microorganisms, and Salmonella were conducted for 133 samples. L. monocytogenes was assessed in 181 samples using the BAX System and by plating the enrichment broth onto Palcam and Oxford agars. Suspected Listeria colonies were submitted to classical biochemical tests. Populations of psychrotrophic microorganisms >10(6) CFU/g were found in 51% of the 133 samples, and Enterobacteriaceae populations between 10(5) and 106 CFU/g were found in 42% of the samples. Fecal coliform concentrations higher than 10(2) CFU/g (Brazilian standard) were found in 97 (73%) of the samples, and Salmonella was detected in 4 (3%) of the samples. Two of the Salmonella-positive samples had <10(2) CFU/g concentrations of fecal coliforms. L. monocytogenes was detected in only 1 (0.6%) of the 181 samples examined. This positive sample was simultaneously detected by both methods. The other Listeria species identified by plating were L. welshimeri (one sample of curly lettuce) and L. innocua (2 samples of watercress). The results indicate that minimally processed vegetables had poor microbiological quality, and these products could be a vehicle for pathogens such as Salmonella and L. monocytogenes.
Alqahtani, Jobran M.; Asaad, Ahmed M.; Ahmed, Essam M.; Qureshi, Mohamed A.
2015-01-01
Aim of the Study: The aim was to investigate the bacteriological quality of drinking water, and explore the factors involved in the knowledge of the public about the quality of drinking water in Najran region, Saudi Arabia. Study Design: A cross-sectional descriptive study. Materials and Methods: A total of 160 water samples were collected. Total coliforms, fecal coliform, and fecal streptococci were counted using Most Probable Number method. The bacterial genes lacZ and uidA specific to total coliforms and Escherichia coli, respectively, were detected using multiplex polymerase chain reaction. An interview was conducted with 1200 residents using a questionnaire. Results: Total coliforms were detected in 8 (20%) of 40 samples from wells, 13 (32.5%) of 40 samples from tankers, and 55 (68.8%) of 80 samples from roof tanks. Twenty (25%) and 8 (10%) samples from roof tanks were positive for E. coli and Streptococcus faecalis, respectively. Of the 1200 residents participating in the study, 10%, 45.5%, and 44.5% claimed that they depended on municipal water, bottled water, and well water, respectively. The majority (95.5%) reported the use of roof water tanks as a source of water supply in their homes. Most people (80%) believed that drinking water transmitted diseases. However, only 25% of them participated in educational programs on the effect of polluted water on health. Conclusions: Our results could help health authorities consider a proper regular monitoring program and a sustainable continuous assessment of the quality of well water. In addition, this study highlights the importance of the awareness and educational programs for residents on the effect of polluted water on public health. PMID:25657607
Survival of pathogenic bacteria in compost with special reference to Escherichia coli.
Gong, Chun-ming; Koichi, Inoue; Shunji, Inanaga; Takashi, Someya
2005-01-01
Application of compost in agricultural practice could potentially cause contamination of foodstuffs with pathogenic bacteria such as Escherichia coli O157:H7 (E. Coli O157). We investigated pathogenic bacteria in compost collected from the compost facilities, and evaluated the survival of E. coli K12 and O157 in laboratory experiments. Out of 19 compost product samples, coliform bacteria and salmonella were detected in 7 and 3 samples respectively. The number of coliform bacteria was 1.8 x 10(2) to 2.5 x 10(6) CFU/g dw and that of salmonella was 4.2 x 10(1) to 6.0 x 10(3) CFU/g dw. Moreover, coliform bacteria, fecal coliform, E. coli and salmonella were detected during composting at 54 degrees C to 67 degrees C. The results indicated that moisture content was a very important factor to the heat sensitivity of pathogenic bacteria in compost, E. coil in compost of high moisture content was more sensitive than that in compost of low moisture content, cells harvested in logarithmic phase was more sensitive than these in stationary phase, and E. coli K12 was more sensitive than E. coli O157. Based on the D values, the lethal time of E. coli K12 and O157 from l0(8) to 10(0) CFU/g dw were 16.3 and 28.8 min, respectively, at 60 degrees C in compost with 40% moisture content. However, some E. coil cells survived in composting process at 54 degrees C to 67 degrees C. Water potential (low moisture content) and physiological aspects of bacteria (stationary phase) could explain only in part of the prolonged survival of E. coil in compost, and there should be some other factors that are conducive to bacterial survival in compost.
Analysis of microbiological contamination in mixed pressed ham and cooked sausage in Korea.
Park, Myoung-Su; Wang, Jun; Park, Joong-Hyun; Forghani, Fereidoun; Moon, Jin-San; Oh, Deog-Hwan
2014-03-01
The objective of this study was to investigate the microbial contamination levels (aerobic bacteria plate count [APC], coliforms, Escherichia coli, Staphylococcus aureus, and Listeria monocytogenes) in mixed pressed ham and cooked sausage. A total of 180 samples were collected from factories with and without hazard analysis critical control point (HACCP) systems at four steps: after chopping (AC), after mixing (AM), cooling after the first heating process, and cooling after the second heating process. For ham, APCs and coliform and E. coli counts increased when ingredients were added to the meat at the AC step. Final product APC was 1.63 to 1.85 log CFU/g, and coliforms and E. coli were not detected. S. aureus and L. monocytogenes were found in nine (15.0%) and six (10.0%) samples, respectively, but only at the AC and AM steps and not in the final product. Sausage results were similar to those for ham. The final product APC was 1.52 to 3.85 log CFU/g, and coliforms and E. coli were not detected. S. aureus and L. monocytogenes were found in 29 (24.2%) and 25 (20.8%) samples at the AC and AM steps, respectively, but not in the final product. These results indicate that the temperature and time of the first and second heating are of extreme importance to ensure the microbiological safety of the final product regardless of whether a HACCP system is in place. Microorganism contamination must be monitored regularly and regulations regarding sanitization during processing should be improved. Education regarding employee personal hygiene, environmental hygiene, prevention of cross-contamination, ingredient control, and step-by-step process control is needed to reduce the risk of food poisoning.
Ortega-Paredes, David; Barba, Pedro; Mena-López, Santiago; Espinel, Nathaly; Zurita, Jeannete
2018-04-30
Dissemination of Extended spectrum β-lactamases (ESBL) Enterobacteriaceae is a major medical threat. Vegetables and fruits, which are usually consumed raw, are a very suitable pathway for the spread of these bacteria from farm-to-fork. However, limited information exists regarding resistant bacteria and epidemic clones that are disseminated in vegetables and tap water in South America. We processed a total of 90 samples in triplicate of nine typically consumed raw vegetables from a central municipal market, and tap water samples were processed from twenty-one locations in Quito, Ecuador. The samples were analyzed for total coliforms and ESBL Enterobacteriaceae contamination using the dilution filtration method. ESBL Escherichia coli isolates were phenotypically and genotypically characterized. The water was free of Enterobacteriaceae, but all the vegetables and fruits (except for blackberries) presented total coliform counts. Watercress had the highest load of total coliforms (3.3 × 10E4). ESBL E. coli was detected in alfalfa, leaf lettuce and parsley/cilantro samples. Alfalfa had the highest load of ESBL E. coli/total coliforms (1/3.3 × 10E2). We identified E. coli ST44-A and ST410-A harboring bla CTX-M-15 downstream of ISEcp1. Alfalfa and parsley/cilantro were contaminated with hyperepidemic E. coli ST410-A, which was resistant to quinolones and harbored bla CTX-M-15 . For the first time, we report ESBL E. coli ST410-A from vegetables and express an alert regarding the health risk this could represent. Copyright © 2018 Elsevier B.V. All rights reserved.
Fernando, Dinesh M.; Tun, Hein Min; Poole, Jenna; Patidar, Rakesh; Li, Ru; Mi, Ruidong; Amarawansha, Geethani E. A.; Fernando, W. G. Dilantha; Khafipour, Ehsan; Farenhorst, Annemieke
2016-01-01
ABSTRACT Access to safe drinking water is now recognized as a human right by the United Nations. In developed countries like Canada, access to clean water is generally not a matter of concern. However, one in every five First Nations reserves is under a drinking water advisory, often due to unacceptable microbiological quality. In this study, we analyzed source and potable water from a First Nations community for the presence of coliform bacteria as well as various antibiotic resistance genes. Samples, including those from drinking water sources, were found to be positive for various antibiotic resistance genes, namely, ampC, tet(A), mecA, β-lactamase genes (SHV-type, TEM-type, CTX-M-type, OXA-1, and CMY-2-type), and carbapenemase genes (KPC, IMP, VIM, NDM, GES, and OXA-48 genes). Not surprisingly, substantial numbers of total coliforms, including Escherichia coli, were recovered from these samples, and this result was also confirmed using Illumina sequencing of the 16S rRNA gene. These findings deserve further attention, as the presence of coliforms and antibiotic resistance genes potentially puts the health of the community members at risk. IMPORTANCE In this study, we highlight the poor microbiological quality of drinking water in a First Nations community in Canada. We examined the coliform load as well as the presence of antibiotic resistance genes in these samples. This study examined the presence of antibiotic-resistant genes in drinking water samples from a First Nations Community in Canada. We believe that our findings are of considerable significance, since the issue of poor water quality in First Nations communities in Canada is often ignored, and our findings will help shed some light on this important issue. PMID:27235436
Quality of water, Quillayute River basin, Washington
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fretwell, M.O.
Ground water in the Quillayute River basin is generally of the calcium bicarbonate type, although water from some wells is affected by seawater intrusion and is predominantly of the sodium chloride type. The water is generally of excellent quality for most uses, with the exception of water in two wells which had iron concentrations that potentially could be tasted in beverages and could cause staining of laundry and porcelain fixtures. A comparison of the chemical compositions of ground and surface waters showed a strong similarity over a wide geographic area. Proportions of the major chemical constituents in the rivers ofmore » the basin were nearly constant despite concentration fluctuations in response to dilution from precipitation and snowmelt. River-water quality was generally excellent, as evaluated against Washington State water use and water-quality criteria. Fecal-coliform bacteria counts generally were much lower than the total-coliform bacteria counts, indicating that most of the coliform bacteria were of nonfecal origin and probably originated in soils. Fecal coliform concentrations in all the major tributaries met State water-quality criteria. Water temperatures occasionally exceeded criteria maximum during periods of warm weather and low streamflow; dissolved-oxygen concentrations were occasionally less than criteria minimum because of increased water temperature. Both conditions occurred naturally. Nutrient concentrations were generally low to very low and about the same as in streams from virgin forestland in the Olympic National Park. However, some slight increases in nutrient concentrations were observed, particularly in the vicinity of Mill Creek and the town of Forks; due to dilution and biological assimilation, these slightly elevated concentrations decreased as the water moved downstream. 35 refs., 24 figs., 16 tabs.« less
Fernando, Dinesh M; Tun, Hein Min; Poole, Jenna; Patidar, Rakesh; Li, Ru; Mi, Ruidong; Amarawansha, Geethani E A; Fernando, W G Dilantha; Khafipour, Ehsan; Farenhorst, Annemieke; Kumar, Ayush
2016-08-01
Access to safe drinking water is now recognized as a human right by the United Nations. In developed countries like Canada, access to clean water is generally not a matter of concern. However, one in every five First Nations reserves is under a drinking water advisory, often due to unacceptable microbiological quality. In this study, we analyzed source and potable water from a First Nations community for the presence of coliform bacteria as well as various antibiotic resistance genes. Samples, including those from drinking water sources, were found to be positive for various antibiotic resistance genes, namely, ampC, tet(A), mecA, β-lactamase genes (SHV-type, TEM-type, CTX-M-type, OXA-1, and CMY-2-type), and carbapenemase genes (KPC, IMP, VIM, NDM, GES, and OXA-48 genes). Not surprisingly, substantial numbers of total coliforms, including Escherichia coli, were recovered from these samples, and this result was also confirmed using Illumina sequencing of the 16S rRNA gene. These findings deserve further attention, as the presence of coliforms and antibiotic resistance genes potentially puts the health of the community members at risk. In this study, we highlight the poor microbiological quality of drinking water in a First Nations community in Canada. We examined the coliform load as well as the presence of antibiotic resistance genes in these samples. This study examined the presence of antibiotic-resistant genes in drinking water samples from a First Nations Community in Canada. We believe that our findings are of considerable significance, since the issue of poor water quality in First Nations communities in Canada is often ignored, and our findings will help shed some light on this important issue. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Skraber, S; Gassilloud, B; Schwartzbrod, L; Gantzer, C
2004-07-01
The microbiological quality of water is currently assessed by search for fecal bacteria indicators. There is, however, a body of knowledge demonstrating that bacterial indicators are less resistant to environmental factors than human pathogenic viruses and therefore underestimate the viral risk. As river water is often used as a resource for drinking water production, it is particularly important to obtain a valid estimation of the health hazard, including specific viral risk. This work was conducted to compare the survival of infectious Poliovirus-1 used as a pathogenic virus model to the persistence of, on the one hand, thermotolerant coliforms commonly used as indicators and on the other hand, to somatic coliphages and Poliovirus-1 genome considered as potential indicators. We studied the behavior of infectious Poliovirus-1 and the three (potential) indicators of viral contamination in river water at three different temperatures (4 degrees C,18 degrees C and 25 degrees C). This experiment was performed twice with river water sampled at two different periods, once in winter and once in summer. Our results showed that the survival of thermotolerant coliforms can be 1.5-fold lower than infectious Poliovirus-1. In contrast, under all our experimental conditions, somatic coliphages and Poliovirus-1 genome persisted longer than infectious Poliovirus-1, surviving, respectively, 2-6-fold and about 2-fold longer than infectious Poliovirus-1. According to our results exclusively based on survival capacity, somatic coliphages and viral genome, unlike thermotolerant coliforms appear to be better indicators of viral contamination in river water. Moreover, the disappearance of viral genome is well-correlated to that one of infectious virus irrespective of the conditions tested.
Upadhaya, Santi Devi; Park, Jae Won; Lee, Jae Hwan; Kim, In Ho
2016-01-01
A study was conducted to determine the efficacy of β-mannanase supplementation to a diet based on corn and soya bean meal (SBM) on growth performance, nutrient digestibility, blood urea nitrogen (BUN), faecal coliforms and lactic acid bacteria, and noxious gas emission in growing pigs. A total of 140 pigs [(Landrace × Yorkshire) × Duroc; average body weight 25 ± 3 kg] were randomly allotted to a 2 × 2 factorial arrangement with dietary treatments consisting of hulled or dehulled SBM without or with supplementation of 400 U β-mannanase/kg. During the 6 weeks of experimental feeding, β-mannanase supplementation had no effect on body weight gain, feed intake and gain:feed (G:F) ratio. Compared with dehulled SBM, feeding hulled SBM caused an increased feed intake of pigs in the entire trial (p = 0.05). The G:F ratio was improved in pigs receiving dehulled SBM (p < 0.05). Dietary treatments did not influence the total tract digestibility of dry matter, nitrogen and gross energy. Enzyme supplementation reduced (p < 0.05) the population of faecal coliforms and tended to reduce the NH3 concentration after 24 h of fermentation in a closed box containing faecal slurry. Feeding hulled SBM tended to reduce NH3 emission on days 3 and 5 of fermentation. In conclusion, mannanase supplementation had no influence on growth performance and nutrient digestibility but showed a positive effect on reducing coliform population and tended to reduce NH3 emission. Dehulled SBM increased G:F ratio and hulled SBM tended to reduce NH3 emission.
Buhr, R J; Berrang, M E; Cason, J A
2003-10-01
Genetically feathered and featherless sibling broilers selected for matched BW were killed, scalded, and defeathered to determine the consequences of feathers and empty feather follicles on the recovery of bacteria from carcass breast skin. In trial 1, the vents of all carcasses were plugged and sutured before scalding to prevent the expulsion of cloacal contents during picking. In trial 2, half of the carcasses had their vents plugged and sutured. Immediately after defeathering, breast skin was aseptically removed, and bacteria associated with it were enumerated. In trial 1, the levels of bacteria recovered did not differ between feathered and featherless carcasses: Campylobacter log10 1.4 cfu/mL of rinse, coliform log10 1.8, Escherichia coli log10 1.6, and total aerobic bacteria log10 3.1. In trial 2, the carcasses that had vents plugged and sutured had lower levels of all four types of bacteria (differences of Campylobacter log10 0.7 cfu/mL, coliform log10 1.8, E. coli log10 1.7, and total aerobic bacteria log10 0.5) than those carcasses with open vents. The lower levels of bacteria recovered from carcasses with the vents plugged and sutured during picking enabled detection of small but significant differences between feathered and featherless carcasses. The level of coliform and E. coli recovered was slightly higher by log10 0.7 cfu for feathered carcasses, but featherless carcasses had marginally higher levels of total aerobic bacteria by log10 0.4 cfu. Feathered and featherless carcasses with open vents during picking did not differ in the levels of recovery of coliform, E. coli, and total aerobic bacteria from breast skin.
Multidrug-Resistant Bacteria Isolated from Surface Water in Bassaseachic Falls National Park, Mexico
Delgado-Gardea, Ma. Carmen E.; Tamez-Guerra, Patricia; Gomez-Flores, Ricardo; Zavala-Díaz de la Serna, Francisco Javier; Eroza-de la Vega, Gilberto; Nevárez-Moorillón, Guadalupe Virginia; Pérez-Recoder, María Concepción; Sánchez-Ramírez, Blanca; González-Horta, María del Carmen; Infante-Ramírez, Rocío
2016-01-01
Bacterial pathogens are a leading cause of waterborne disease, and may result in gastrointestinal outbreaks worldwide. Inhabitants of the Bassaseachic Falls National Park in Chihuahua, Mexico show seasonal gastroenteritis problems. This aim of this study was to detect enteropathogenic microorganisms responsible for diarrheal outbreaks in this area. In 2013, 49 surface water samples from 13 selected sampling sites along the Basaseachi waterfall and its main rivers, were collected during the spring, summer, autumn, and winter seasons. Fecal and total coliform counts were determined using standard methods; the AutoScan-4 system was used for identification of isolates and the antibiotic resistance profile by challenging each organism using 21 antibiotics. Significant differences among seasons were detected, where autumn samples resulted in the highest total (p < 0.05) and fecal (p < 0.001) coliform counts, whereas the lowest total coliform counts were recorded in spring. Significant differences between sampling sites were observed, where samples from sites 6, 8, and 11 had the highest total coliform counts (p < 0.009), whereas samples from site 9 exhibited the lowest one. From the microbiological analysis, 33 bacterial isolates from 13 different sites and four sampling seasons were selected; 53% of isolates were resistant to at least one antibiotic, and 15% exhibited a multidrug resistance (MDB) phenotype. MDB were identified as Klebsiella oxytoca (two out of four identified isolates), Escherichia coli (2/7), and Enterobacter cloacae (1/3). In addition, some water-borne microorganisms exhibited resistance to cefazoline, cefuroxime, ampicillin, and ampicillin-sulbactam. The presence of these microorganisms near rural settlements suggests that wastewater is the contamination source, providing one possible transmission mechanism for diarrheal outbreaks. PMID:27322297
Kelly, Brian P.; Rydlund, Jr., Paul H.
2006-01-01
Riverbank filtration substantially improves the source-water quality of the Independence, Missouri well field. Coliform bacteria, Cryptosporidium, Giardia, viruses and selected constituents were analyzed in water samples from the Missouri River, two vertical wells, and a collector well. Total coliform bacteria, Cryptosporidium, Giardia, and total culturable viruses were detected in the Missouri River, but were undetected in samples from wells. Using minimum reporting levels for non-detections in well samples, minimum log removals were 4.57 for total coliform bacteria, 1.67 for Cryptosporidium, 1.67 for Giardia, and 1.15 for total culturable virus. Ground-water flow rates between the Missouri River and wells were calculated from water temperature profiles and ranged between 1.2 and 6.7 feet per day. Log removals based on sample pairs separated by the traveltime between the Missouri River and wells were infinite for total coliform bacteria (minimum detection level equal to zero), between 0.8 and 3.5 for turbidity, between 1.5 and 2.1 for Giardia, and between 0.4 and 2.6 for total culturable viruses. Cryptosporidium was detected once in the Missouri River but no corresponding well samples were available. No clear relation was evident between changes in water quality in the Missouri River and in wells for almost all constituents. Results of analyses for organic wastewater compounds and the distribution of dissolved oxygen, specific conductance, and temperature in the Missouri River indicate water quality on the south side of the river was moderately influenced by the south bank inflows to the river upstream from the Independence well field.
The application of the hazard analysis and control points (HACCP) in an ice cream production plant.
El-Tawila, M M
1998-01-01
The HACCP system is applied in the present study as a preventive food safety approach to control some hazards appearing in one of the ice cream production plants in Egypt. The problem comprised the presence of bacteriological and some chemical contamination in most of the company products. Before applying the HACCP system, the samples examination showed high total mesophilic plat count in 50% of the samples and high coliform count in all samples compared to the level recommended in the Egyptian standards. The highest staphylococcal count (negative for coagulase test) obtained was that of chocolate (1.3 x 10(4) CFU/g) followed by mango ice cream (l.0 x 10(4) CFU/g). Faecal coliform was only positive in mango ice cream. Additionally, the levels of lead, iron and copper have been determined. Copper was higher than the recommended level in all samples and ranged between 0.46 ppm in pistachio ice cream and 2.48 ppm in chocolate ice cream. Most of the CCPs in the ice cream production were mainly due to improper handling and practices throughout the processing steps and also related to the lack of food hygiene knowledge of the workers. The application of HACCP system has successfully reduced the bacteriological hazards in all samples. After applying the corrective actions, the highest total aerobic plate count (8.0 x 10(4)) was that of Swiss chocolate ice cream which corresponds to 50% of the recommended level by the Egyptian standards. Coliform count was less than 10 in all samples except mango ice cream (43 MPN). A significant decrease in staphylococcal count, faecal coliform and trace metal contamination was also recorded in all samples.
Microbiological Implications of Periurban Agriculture and Water Reuse in Mexico City
Mazari-Hiriart, Marisa; Ponce-de-León, Sergio; López-Vidal, Yolanda; Islas-Macías, Pilar; Amieva-Fernández, Rosa Isabel; Quiñones-Falconi, Francisco
2008-01-01
Background Recycled treated or untreated wastewater represents an important health challenge in developing countries due to potential water related microbiological exposure. Our aim was to assess water quality and health implications in a Mexico City periurban agricultural area. Methodology/Principal Findings A longitudinal study in the Xochimilco wetland area was conducted, and 42 sites were randomly selected from 211, including irrigation water canals and effluents of treatment plants. Sample collection took place during rainy and dry seasons (2000–2001). Microbiological parameters (total coliforms, fecal coliforms, streptococci/enterococci, and bacteria other than Vibrio grown on TCBS), Helicobacter pylori, and physicochemical parameters including trihalomethanes (THM) were determined. Fecal coliforms and fecal streptococci are appropriate indicators of human or animal fecal contamination. Fecal coliform counts surpass Mexican and World Health Organization irrigation water guidelines. Identified microorganisms associated with various pathologies in humans and domestic animals comprise Escherichia coli, Klebsiella spp., Salmonella spp., Enterobacter spp., Enterococcus spp., and Pseudomonas spp; H. pylori was also present in the water. An environmental characteristic of the canal system showed high Total Organic Carbon content and relatively low dissolved oxygen concentration; residual chlorine as a disinfection control is not efficient, but THMs do not represent a problem. During the rainy season, temperature and conductivity were higher; in contrast, pH, dissolved oxygen, ammonia, and residual chlorine were lower. This is related with the continuous load of feces from human and animal sources, and to the aquatic systems, which vary seasonally and exhibit evidence of lower water quality in effluents from treatment plants. Conclusions/Significance There is a need for improvement of wastewater treatment systems, as well as more efficient monitoring, regulation, and enforcement procedures for wastewater disposal into bodies of water. PMID:18509453
Leight, Andrew K.; Crump, Byron C.; Hood, Raleigh R.
2018-01-01
Routine monitoring of shellfish growing waters for bacteria indicative of human sewage pollution reveals little about the bacterial communities that co-occur with these indicators. This study investigated the bacterial community, potential pathogens, and fecal indicator bacteria in 40 water samples from a shellfish growing area in the Chesapeake Bay, USA. Bacterial community composition was quantified with deep sequencing of 16S rRNA gene amplicons, and absolute gene abundances were estimated with an internal standard (Thermus thermophilus genomes). Fecal coliforms were quantified by culture, and Vibrio vulnificus and V. parahaemolyticus with quantitative PCR. Fecal coliforms and V. vulnificus were detected in most samples, and a diverse assemblage of potential human pathogens were detected in all samples. These taxa followed two general patterns of abundance. Fecal coliforms and 16S rRNA genes for Enterobacteriaceae, Aeromonas, Arcobacter, Staphylococcus, and Bacteroides increased in abundance after a 1.3-inch rain event in May, and, for some taxa, after smaller rain events later in the season, suggesting that these are allochthonous organisms washed in from land. Clostridiaceae and Mycobacterium 16S rRNA gene abundances increased with day of the year and were not positively related to rainfall, suggesting that these are autochthonous organisms. Other groups followed both patterns, such as Legionella. Fecal coliform abundance did not correlate with most other taxa, but were extremely high following the large rainstorm in May when they co-occurred with a broad range of potential pathogen groups. V. vulnificus were absent during the large rainstorm, and did not correlate with 16S rRNA abundances of Vibrio spp. or most other taxa. These results highlight the complex nature of bacterial communities and the limited utility of using specific bacterial groups as indicators of pathogen presence. PMID:29593669
Delgado-Gardea, Ma Carmen E; Tamez-Guerra, Patricia; Gomez-Flores, Ricardo; Zavala-Díaz de la Serna, Francisco Javier; Eroza-de la Vega, Gilberto; Nevárez-Moorillón, Guadalupe Virginia; Pérez-Recoder, María Concepción; Sánchez-Ramírez, Blanca; González-Horta, María Del Carmen; Infante-Ramírez, Rocío
2016-06-16
Bacterial pathogens are a leading cause of waterborne disease, and may result in gastrointestinal outbreaks worldwide. Inhabitants of the Bassaseachic Falls National Park in Chihuahua, Mexico show seasonal gastroenteritis problems. This aim of this study was to detect enteropathogenic microorganisms responsible for diarrheal outbreaks in this area. In 2013, 49 surface water samples from 13 selected sampling sites along the Basaseachi waterfall and its main rivers, were collected during the spring, summer, autumn, and winter seasons. Fecal and total coliform counts were determined using standard methods; the AutoScan-4 system was used for identification of isolates and the antibiotic resistance profile by challenging each organism using 21 antibiotics. Significant differences among seasons were detected, where autumn samples resulted in the highest total (p < 0.05) and fecal (p < 0.001) coliform counts, whereas the lowest total coliform counts were recorded in spring. Significant differences between sampling sites were observed, where samples from sites 6, 8, and 11 had the highest total coliform counts (p < 0.009), whereas samples from site 9 exhibited the lowest one. From the microbiological analysis, 33 bacterial isolates from 13 different sites and four sampling seasons were selected; 53% of isolates were resistant to at least one antibiotic, and 15% exhibited a multidrug resistance (MDB) phenotype. MDB were identified as Klebsiella oxytoca (two out of four identified isolates), Escherichia coli (2/7), and Enterobacter cloacae (1/3). In addition, some water-borne microorganisms exhibited resistance to cefazoline, cefuroxime, ampicillin, and ampicillin-sulbactam. The presence of these microorganisms near rural settlements suggests that wastewater is the contamination source, providing one possible transmission mechanism for diarrheal outbreaks.
Drinking water quality assessment.
Aryal, J; Gautam, B; Sapkota, N
2012-09-01
Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.
Validation of a 2 percent lactic acid antimicrobial rinse for mobile poultry slaughter operations.
Killinger, Karen M; Kannan, Aditi; Bary, Andy I; Cogger, Craig G
2010-11-01
Poultry processing antimicrobial interventions are critical for pathogen control, and organic, mobile operations in Washington seek alternatives to chlorine. Laboratory and field studies (three replications each) evaluated lactic acid efficacy as a chlorine alternative. For the laboratory study, retail-purchased, conventionally processed chicken wings inoculated with Salmonella were randomly assigned to the following treatments: Salmonella inoculation followed by no treatment (10 wings) or by 3-min rinses of water, 50 to 100 ppm of chlorine, or 2% lactic acid (20 wings for each rinse treatment). Wings were sampled for Salmonella enumeration on xylose lysine desoxycholate agar. During pastured poultry processing at mobile slaughter units for each field study replication, 20 chicken carcasses were randomly assigned to each treatment: untreated control or 3-min immersion in lactic acid or chlorine. Whole-carcass rinses were examined for aerobic plate count (APC) on tryptic soy agar and coliforms on violet red bile agar. Untreated controls were also examined for Salmonella. In the laboratory study, lactic acid produced a significant (P < 0.01) Salmonella reduction compared with the inoculated no-rinse, water, and chlorine treatments, which were statistically similar to each other. In the field study, no Salmonella was detected on untreated controls. Lactic acid produced significant >2-log (P < 0.01) reductions in APC and coliforms, whereas chlorine resulted in slight, but significant 0.4-log reductions (P < 0.01) and 0.21-log reductions (P < 0.05) in APC and coliforms compared with untreated controls. Considering laboratory and field studies, lactic acid produced greater reductions in Salmonella, APC, and coliforms, validating its effectiveness as a chlorine alternative in mobile poultry slaughter operations.
On-farm and postharvest processing sources of bacterial contamination to melon rinds.
Gagliardi, J V; Millner, P D; Lester, G; Ingram, D
2003-01-01
Multistate and international foodborne illness outbreaks, particularly involving cantaloupe and often involving rare Salmonella spp., have increased dramatically over the past 13 years. This study assessed the sources and extent of melon rind contamination in production fields and at processing and packing facilities. In the spring of 1999, cantaloupe (Cucumis melo L. [reticulatus group] cv. Cruiser) sampled from two sites in the Rio Grande River Valley showed that postharvest-processed melon rinds often had greater plate counts of bacterial contaminants than field-fresh melons. Cantaloupe in the field had 2.5 to 3.5 log CFU g(-1) rind total coliforms by aerobic plate counts, whereas washed melons had 4.0 to 5.0 log CFU g(-1). In the fall of 1999, coliforms on honeydew melons (C. melo [inodorous group] cv. Honey Brew) ranged from 2.6 to 3.7 log CFU g(-1) after processing, and total and fecal coliforms and enterococci never fell below 2.5 log CFU g(-1). A hydrocooler at another site contaminated cantaloupe rinds with up to 3.4 log CFU g(-1) total and fecal enterococci; a secondary rinse with chlorinated water incompletely removed these bacteria. Sources of coliforms and enterococci were at high levels in melon production soils, especially in furrows that were flood irrigated, in standing water at one field, and in irrigation water at both sites. At one processing facility, wash water pumped from the Rio Grande River may not have been sufficiently disinfected prior to use. Because soil, irrigation water, and process water were potential sources of bacterial contamination, monitoring and management on-farm and at processing and packing facilities should focus on water quality as an important control point for growers and packers to reduce bacterial contamination on melon rinds.
Herrero-Fresno, Ana; Zachariasen, Camilla; Nørholm, Nanna; Holm, Anders; Christiansen, Lasse Engbo; Olsen, John Elmerdahl
2017-09-01
A major concern derived from using antimicrobials in pig production is the development of resistance. This study aimed to assess the impact of selected combinations of oral dose and duration of treatment with oxytetracycline (OTC) on selection of tetracycline resistant (TET-R) coliforms recovered from swine feces. The work encompassed two studies: 1) OTC 5mg/kg and 20mg/kg were administered to nursery pigs for 3 and 10days, respectively, under controlled experimental conditions, and 2) 10mg/kg, 20mg/kg and 30mg/kg OTC were given to a higher number of pigs for 6, 3 and 2days, respectively, under field conditions. Statistical modeling was applied to analyze trends in the proportion of TET-R coliforms. In the experimental study, no statistical difference in proportion of TET-R coliforms was observed between treatments at the end of the trial (day 18) and compared to day 0. In the field study, treatment had a significant effect on the proportion of TET-R bacteria two days after the end of treatment (2dAT) with the regimes "low dose-six days" and "medium dose-three days" yielding the highest and lowest proportions of TET-R strains, respectively. No indication of co-selection for ampicillin- and sulphonamide -R bacteria was observed for any treatment at 2dAT. By the end of the nursery period, the proportion of TET-R bacteria was not significantly different between treatments and compared to day 0. Our results suggest that similar resistance levels might be obtained by using different treatment regimes regardless of the combinations of oral dose-duration of treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Effects of a tropical cyclone on the drinking-water quality of a remote Pacific island.
Mosley, Luke M; Sharp, Donald S; Singh, Sarabjeet
2004-12-01
The effect of a cyclone (Ami, January 2003) on drinking-water quality on the island of Vanua Levu, Fiji was investigated. Following the cyclone nearly three-quarters of the samples analysed did not conform to World Health Organisation (WHO) guideline values for safe drinking-water in terms of chlorine residual, total and faecal coliforms, and turbidity. Turbidity and total coliform levels significantly increased (up 56 and 62 per cent, respectively) from pre-cyclone levels, which was likely due to the large amounts of silt and debris entering water-supply sources during the cyclone. The utility found it difficult to maintain a reliable supply of treated water in the aftermath of the disaster. Communities were unaware they were drinking water that had not been adequately treated. Circumstances permitted this cyclone to be used as a case study to assess whether a simple paper-strip water-quality test (the hydrogen sulphide, H(2)S) kit could be distributed and used for community-based monitoring following such a disaster event to better protect public health. The H(2)S test results correlated well with faecal and total coliform results as found in previous studies. A small percentage of samples (about 10 per cent) tested positive for faecal and total coliforms but did not test positive in the H(2)S test. It was concluded that the H(2)S test would be well suited to wider use, especially in the absence of water-quality monitoring capabilities for outer island groups as it is inexpensive and easy to use, thus enabling communities and community health workers with minimal training to test their own water supplies without outside assistance. The importance of public education before and after natural disasters is also discussed.
Azman, J; Init, I; Wan Yusoff, W S
2009-12-01
This study is the first report on the occurrence of Giardia and Cryptosporidium (oo)cysts in recreational rivers water from Malaysia. It was carried out in water samples at two rivers, 'Sungai Congkak' and 'Sungai Batu', located in Selangor State. The occurrence of both Giardia lamblia and Cryptosporidium parvum (oo)cysts was higher in Sungai Congkak (50% or 15/30 and 10% or 3/30 respectively) than Sungai Batu (16% or 5/30 and 3.3% or 1/30 respectively). The mean density of cysts/L was 0.72 in Sungai Congkak and 0.023 in Sungai Batu, and that of oocysts/L was 0.023 in Sungai Congkak and 0.0033 in Sungai Batu, showing that the occurrence of Giardia was higher and more frequent than Cryptosporidium in both rivers. Sungai Congkak also showed higher faecal coliforms count (ranging from 0.48x10³ to 73x10³ CFU/100 mL) than Sungai Batu (0.41x10³ to 16x10³ CFU/100 mL). On the other hand, the Giardia and Cryptosporidium (oo)cysts and faecal coliforms were more concentrated at the downstream station, followed by midstream and upstream stations which might be due to human factors where settlements and recreation areas were located around and between midstream and downstream stations. The (oo)cysts and faecal coliforms also increased during public holidays due to the significantly higher number of visitors (bathers) compared with the week days. All the parameters (physical, faecal coliforms and rainfall) did not show consistent significant correlation (based on r values of Pearson correlation analysis) with both protozoa, therefore these parameters are not suitable as indicator for the presence of Giardia and Cryptosporidium (oo)cysts in both rivers.
Subba, P; Joshi, D R; Bhatta, D R
2013-01-01
Antibiotic resistant Escherichia coli is potential source of transmission of resistance to other water borne pathogens where plasmid borne resistance is most significant. Drinking water samples were collected from different water sources: that is to say- tap, well and spring from different places of Kathmandu where E. coli and thermotolerant E. coli were isolated using membrane filtration technique. Antibiotic susceptibility was determined using a modified Kirby Bauer disc diffusion method and thermotolerant E. coli isolates from tap water were subjected for plasmid profiling. Type of water sources were not associated with the presence of coliform (P=0.155) and thermotolerant coliform (P=0.235) but the significant association was observed in thermotolerant coliform and thermotolerant E. coli for all sources tap (P=0.029), well (P=0.028), spring (P=0.05) but total coliform and E. coli association was found for well (P=0.01). All E. coli and thermotolerant E. coli isolates were susceptible to Ofloxacin, Chloramphenicol and Cotrimixazole. Resistance to Cefexime, Amikacin, Nalidixic acid, Amoxicillin, Tetracycline were 17 (54.8%), 9 (29%), 11 (35.5%), 25 (80.6%), 29 (93.5%) and 19 (57.6%), 12 (36.4%), 13 (39.4%), 31 (94%), 33 (100%) was observed in E. coli and thermotolerant E. coli respectively where 25 (75.8%) thermotolerant E. coli and 22 (70.9%) E. coli were observed with multiple drug resistance patterns. Single band of plasmid were observed in three MDRs and one non-MDR isolates and size varied from 2kb to >10kb. All Nalidixic acid resistant thermotolerant E. coli were found to harbor a plasmid. Presence of plasmid in Nalidixic acid resistant thermotolerant E. coli heightens public health issue and the need of monitoring Quinolone resistance bacteria in environment.
Bautista-De León, H; Gómez-Aldapa, C A; Rangel-Vargas, E; Vázquez-Barrios, E; Castro-Rosas, J
2013-06-01
The presence of coliform bacteria, faecal coliforms, Escherichia coli, diarrhoeagenic E. coli pathotypes (DEP) and Salmonella were determined in ready-to-eat cooked vegetable salads (RECS) from restaurants in Pachuca city, Mexico. The RECS were purchased from three types of restaurants: national chain restaurants (A), local restaurants (B) and small restaurants (C). Two restaurants for each A and B, and three for C, were included. Forty RECS samples were purchased at each A and B restaurant and 20 at each C restaurant. Of the overall total of 220 analysed samples, 100, 98·2, 72·3, 4·1 and 4·1% had coliform bacteria, faecal coliforms, E. coli, DEP and Salmonella, respectively. Identified DEP included enteropathogenic E. coli (EPEC), enterotoxigenic E. coli (ETEC) and Shiga toxin-producing E. coli (STEC). The EPEC, ETEC and STEC were isolated each from 1·4% of samples. No E. coli O157:H7 were detected in any STEC-positive samples. The analysis of Kruskal-Wallis anova and median test of microbiological data showed that the microbiological quality of RECS did not differ between the different restaurants (P > 0·05). This is the first report regarding microbiological quality and Salmonella, enteropathogenic E. coli (EPEC), enterotoxigenic E. coli (ETEC) and Shiga toxin-producing E. coli (STEC) isolation from ready-to-eat cooked vegetable salads from Mexican restaurants. Ready-to-eat cooked vegetable salads could be an important factor contributing to the endemicity of EPEC, ETEC and STEC, and Salmonella caused gastroenteritis in Mexico. © 2013 The Society for Applied Microbiology.
Microbiological implications of periurban agriculture and water reuse in Mexico City.
Mazari-Hiriart, Marisa; Ponce-de-León, Sergio; López-Vidal, Yolanda; Islas-Macías, Pilar; Amieva-Fernández, Rosa Isabel; Quiñones-Falconi, Francisco
2008-05-28
Recycled treated or untreated wastewater represents an important health challenge in developing countries due to potential water related microbiological exposure. Our aim was to assess water quality and health implications in a Mexico City periurban agricultural area. A longitudinal study in the Xochimilco wetland area was conducted, and 42 sites were randomly selected from 211, including irrigation water canals and effluents of treatment plants. Sample collection took place during rainy and dry seasons (2000-2001). Microbiological parameters (total coliforms, fecal coliforms, streptococci/enterococci, and bacteria other than Vibrio grown on TCBS), Helicobacter pylori, and physicochemical parameters including trihalomethanes (THM) were determined. Fecal coliforms and fecal streptococci are appropriate indicators of human or animal fecal contamination. Fecal coliform counts surpass Mexican and World Health Organization irrigation water guidelines. Identified microorganisms associated with various pathologies in humans and domestic animals comprise Escherichia coli, Klebsiella spp., Salmonella spp., Enterobacter spp., Enterococcus spp., and Pseudomonas spp; H. pylori was also present in the water. An environmental characteristic of the canal system showed high Total Organic Carbon content and relatively low dissolved oxygen concentration; residual chlorine as a disinfection control is not efficient, but THMs do not represent a problem. During the rainy season, temperature and conductivity were higher; in contrast, pH, dissolved oxygen, ammonia, and residual chlorine were lower. This is related with the continuous load of feces from human and animal sources, and to the aquatic systems, which vary seasonally and exhibit evidence of lower water quality in effluents from treatment plants. There is a need for improvement of wastewater treatment systems, as well as more efficient monitoring, regulation, and enforcement procedures for wastewater disposal into bodies of water.
Wahba, Nahed M; Ahmed, Amany S; Ebraheim, Zedan Z
2010-04-01
This study was designed to assess the application of some edible plants including cayenne, green pepper, parsley, and dill to Kareish cheese and to evaluate the antimicrobial activity of these plant materials against natural microflora, coliforms, molds, and Staphylococcus aureus. Twelve different concentrations of ethanol extract of the plants were prepared for determination of the minimal inhibitory concentration. Cayenne and green pepper extracts showed highest activity followed by dill and parsley against S. aureus. Addition of cayenne or green pepper to Kareish cheese during manufacture revealed that both plants were able reduce the S. aureus population to undetectable level within the first and second days of storage. To study the effect of combining plant materials on the microbiological quality of ready-to-eat Kareish cheese, the total bacterial count, coliform count, and yeast and molds counts were determined. It has been found that addition of plant materials to Kareish cheese reduced the total bacterial and coliform populations. All concentrations of cayenne, green pepper, dill, and parsley (9%) completely reduced the yeast count within 2 hours. Cayenne and green pepper completely reduced the mold count within 2 days, whereas parsley and dill were found to be less effective. Kareish cheese prepared with 1% cayenne pepper and 3% and 6% each of green pepper, dill, and parsley were found strongly acceptable to the consumer and considered the most preferable type. Therefore, this study revealed that pepper, parsley, and dill exhibited antibacterial activity against natural microflora, coliforms, yeast and molds, and S. aureus in Kareish cheese, and the addition of these plants is acceptable to the consumer and may contribute to the development of new and safe varieties of Kareish cheese.
2004-02-19
County 142.9 17 421 60 2253 3800 PO-POBLVD Port Orchard Blvd Port Orchard 314.6 17 291 20 3119 14000 PSNS015 Naval Station McDonalds PSNS 109.5 12 1629...Stream Mouth south of Bea 47.55253 -122.60112 1 1 BL- KFC (BJ01) ECOLOGY BLACKJACK CREEK ( KFC ) Behind KFC 47.54172 -122.62777 1 1 OC KPUD OLNEY CREEK...Com/Res/Rec is a 36” diameter smooth bore concrete storm water outfall pipe located adjacent to McDonalds , near the south side of the drive-through
NASA Technical Reports Server (NTRS)
Grana, D. C.
1979-01-01
The results of two research programs to determine the optimum detector design for measuring fecal coliforms in saline waters for operational systems are presented. One program was concerned with the effects of temperature and salinity on endpoint response time, and the other, the interaction between electrode configurations and the test organisms. Test results show that the endpoint response time is related to salinity and seawater temperature; however, these results can be minimized by the correct choice of growth media. Electrode configurations were developed from stainless steel, Parlodion-coated stainless steel, and platinum that circumvented problems associated with the commercial redox electrodes.
Effects of septic tank effluent on ground-water quality, Dade County, Florida: an interim report
Pitt, William A.
1974-01-01
Except at one site, no fecal coliforms were found below the 10-foot depth. Total coliforms exceeded a count of one colony per ml at the 60- foot depth at two sites. At one site a fecal streptococci count of 53 colonies per ml was found at the 60-foot depth and at another a count of seven colonies was found at the 40-foot depth. The three types of bacteria occur in higher concentration in the northern areas of the county than in the south. Bacteria concentrations were also higher where the septic tanks were more concentrated.
NASA Technical Reports Server (NTRS)
Munoz, E. F.; Silverman, M. P.
1979-01-01
A single-step most-probable-number method for determining the number of fecal coliform bacteria present in sewage treatment plant effluents is discussed. A single growth medium based on that of Reasoner et al. (1976) and consisting of 5.0 gr. proteose peptone, 3.0 gr. yeast extract, 10.0 gr. lactose, 7.5 gr. NaCl, 0.2 gr. sodium lauryl sulfate, and 0.1 gr. sodium desoxycholate per liter is used. The pH is adjusted to 6.5, and samples are incubated at 44.5 deg C. Bacterial growth is detected either by measuring the increase with time in the electrical impedance ratio between the innoculated sample vial and an uninnoculated reference vial or by visual examination for turbidity. Results obtained by the single-step method for chlorinated and unchlorinated effluent samples are in excellent agreement with those obtained by the standard method. It is suggested that in automated treatment plants impedance ratio data could be automatically matched by computer programs with the appropriate dilution factors and most probable number tables already in the computer memory, with the corresponding result displayed as fecal coliforms per 100 ml of effluent.
Microbiological evaluation of South Australian rock lobster meat.
Yap, A S
1977-12-01
Samples of frozen precooked rock lobster meat from five South Australian fish-processing plants situated in the West Coast and south-east regions were tested over a period of six months during the 1974/5 lobster fishing season. The most probable number (MPN) of E. coli and coliforms, Staphylococcus aureus and Salmonella, as well as total plate count (TPC) were determined in 480 samples. Monthly geometric mean TPC ranged from 1600/g to 25,000/g. The highest geometric mean of the MPN of coliforms and E. coli were 4.9/g and 1.8/g respectively. The highest geometric mean number of staphylococci was 18.6/g. Salmonella was not detected in the 480 units tested. Only 0.4% of the samples had TPC exceeding 100,000/g. Coliforms and E. coli were not present in 76.1% and 92.7% respectively of the samples tested. Staphylococcus aureus was not detected in 67.7% of the samples. The numbers of organisms in 82% of the samples fall within the microbiological standards proposed by the National Health and Medical Research Council of Australia for frozen precooked foods. The results of this study demonstrate the microbial quality of precooked lobster meat attainable when good manufacturing practices are used.
Ghosh, Sudipta; Mehla, Ram Kumar
2012-03-01
Thirty-six Holstein cross calves 5 days of age in their preruminant stage were used to study the effect of feeding prebiotic (mannanoligosaccharide) on their performance up to the age of 2 months. Treatment and control groups consisted of 18 calves each. Treatment group was supplemented with 4 g prebiotic (mannanoligosaccharide)/calf/day. Performance was evaluated by measuring average body weight (BW) gain, feed intake [dry matter (DM), total digestible nutrient (TDN) and crude protein(CP)], feed conversion efficiency (DM, TDN, and CP), fecal score, fecal coliform count and feeding cost. Body weight measured weekly, feed intake measured twice daily, proximate analysis of feeds and fodders analyzed weekly, fecal score monitored daily and fecal coliform count done weekly. There was a significant increase in average body weight gain, feed intake and feed conversion efficiency; and a significant decrease in severity of scours as measured by fecal score and fecal coliform count in the treatment group compared with control group (P < 0.01). Feed cost/kg BW gain was significantly lower in the treatment group compared to control group (P < 0.01). The results suggest that prebiotic (mannanoligosaccharide) can be supplemented to the calves for better performance.
Smith, Tamara; Krometis, Leigh-Anne H; Hagedorn, Charles; Lawrence, Annie H; Benham, Brian; Ling, Erin; Ziegler, Peter; Marmagas, Susan West
2014-12-01
Over 1.7 million Virginians rely on private water sources to provide household water. The heaviest reliance on these systems occurs in rural areas, which are often underserved with respect to available financial resources and access to environmental health education. This study aimed to identify potential associations between concentrations of fecal indicator bacteria (FIB) (coliforms, Escherichia coli) in over 800 samples collected at the point-of-use from homes with private water supply systems and homeowner-provided demographic data (household income and education). Of the 828 samples tested, 349 (42%) of samples tested positive for total coliform and 55 (6.6%) tested positive for E. coli. Source tracking efforts targeting optical brightener concentrations via fluorometry and the presence of a human-specific Bacteroides marker via quantitative real-time polymerase chain reaction (qPCR) suggest possible contamination from human septage in over 20 samples. Statistical methods implied that household income has an association with the proportion of samples positive for total coliform, though the relationship between education level and FIB is less clear. Further exploration of links between demographic data and private water quality will be helpful in building effective strategies to improve rural drinking water quality.
Marron, Donna C.; Blanchard, Stephen F.
1995-01-01
Data on water velocity, temperature, specific con- ductance, pH, dissolved oxygen concentration, chlorophyll concentration, suspended sediment con- centration, fecal-coliform counts, and the percen- tage of suspended sediment finer than 62 micrometers ranged up to 21 percent; and cross-section coefficients of variation of the concentrations of suspended sediment, fecal coliform, and chlorophyll ranged from 7 to 115 percent. Midchannel measure- ments of temperature, specific conductance, and pH were within 5 percent of mean cross-sectional values of these properties at the eight sampling sites, most of which appear well mixed because of the effect of dams and reservoirs. Measurements of the concentration of dissolved oxygen at various cross- section locations and at variable sampling depths are required to obtain a representative value of this constituent at these sites. The large varia- bility of concentrations of chlorophyll and suspended sediment, and fecal-coliform counts at the eight sampling sites indicates that composite rather than midchannel or mean values of these constituents are likely to be most representative of the channel cross section.
[Microbiological studies in poultry meat production].
Monov, G
1981-01-01
Microbiologic studies were carried out in the production of poultry meat in a poultry dressing combine of the Stork system. Examined were a total of 125 washing samples taken at the 9th, 11th and 15th hour from the scalding vat, the cooling vat, the machine of eviscerating and the skin surface after plucking, eviscerating and shower washing and prior to packing the carcasses. It was found that the count of aerobic organisms continuously rose during the technologic processing of the slaughtered birds with regard to the surface of the carcasses, the peak values of the total counts and that of coliforms being reached during evisceration. It was further established that shower washing of the carcasses immediately following evisceration guaranteed a washing effect so far as the microflora on the surface was concerned, amounting to 77.60 per cent. So far as the coliform bacteria was concerned this effect was found to be equal to 89.78 per cent. The total count of aerobic microflora on the surface of carcasses prior to packing was found to vary within the range of 3000 to 72000, while the count of coliforms ranged from 100 to 1800/cm2.
Vahedi, M; Nasrolahei, M; Sharif, M; Mirabi, A M
2013-06-01
The quality of milk is influenced by different bacteria present in milk. This study was undertaken to investigate the bacterial contamination of raw and pasteurized milk in Sari Township, Iran, 2011. In this investigation, 100 pasteurized milk samples were collected randomly from the super markets in the city and 100 raw milk samples from 4 dairy farms from suburb areas and evaluated for the presence of coliforms, Escherichia coli, Staphylococcus aureus and Listeria monocytogenes by culture methods and biochemical tests. Data analysis was performed by SPSS software using Chi2 test and described in percentage. In the raw milk, contamination with E. coli, coliforms and Staphylococcus aureus was observed in 42 (42%), 36 (36%) and 22 (22%) of samples respectively, and the same for the pasteurized milk samples was 9 (9%), 2 (2%) and 2 (2%), respectively. Listeria monocytogenes was not detected in any sample. Presence of E. coli in the milk could be due to contamination with waste water and fecal materials. Considering the contamination of raw and pasteurized milk with E. coli and coliforms, sanitary practice during collecting and transporting, particularly in the summer season is recommended.
Integrating water quality responses to best management practices in Portugal.
Fonseca, André; Boaventura, Rui A R; Vilar, Vítor J P
2018-01-01
Nutrient nonpoint pollution has a significant impact on water resources worldwide. The main challenge of this work was to assess the application of best management practices in agricultural land to comply with water quality legislation for surface waters. The Hydrological Simulation Program-FORTRAN was used to evaluate water quality of Ave River in Portugal. Best management practices (infiltration basin) (BMP) were applied to agricultural land (for 3, 6, 9, 12, and 15% area) with removal efficiencies of 50% for fecal coliforms and 30% for nitrogen, phosphorus, and biochemical oxygen demand. The inflow of water quality constituents was reduced for all scenarios, with fecal coliforms achieving the highest reduction between 5.8 and 28.9% and nutrients and biochemical oxygen demand between 2 and 13%. Biochemical oxygen demand and orthophosphates concentrations achieved a good water quality status according to the European Legislation for scenarios of BMP applied to 3 and 12% agricultural area, respectively. Fecal coliform levels in Ave River basin require further treatment to fall below the established value in the abovementioned legislation. This study shows that agricultural watersheds such as Ave basins demand special attention in regard to nonpoint pollution sources effects on water quality and nutrient loads.
Enteropathogenic Bacteria Contamination of Unchlorinated Drinking Water in Korea, 2010
Lee, Si Won; Lee, Do Kyung; An, Hyang Mi; Cha, Min Kyeong; Kim, Kyung Jae
2011-01-01
Objectives The purpose of this study was to assess the microbiological quality of unchlorinated drinking water in Korea, 2010. One hundred and eighty unchlorinated drinking water samples were collected from various sites in Seoul and Gyeonggi province. Methods To investigate bacterial presence, the pour plate method was used with cultures grown on selective media for total bacteria, total coliforms, and Staphylococcus spp., respectively. Results In the 180 total bacteria investigation, 72 samples from Seoul and 33 samples from Gyeonggi province were of an unacceptable quality (>102 CFU/mL). Of all the samples tested, total coliforms were detected in 28 samples (15.6%) and Staphylococcus spp. in 12 samples (6.7%). Most of the coliform isolates exhibited high-level resistance to cefazolin (88.2%), cefonicid (64.7%) and ceftazidime (20.6%). In addition, Staphylococcus spp. isolates exhibited high-level resistance to mupirocin (42%). Species of Pseudomonas, Acinetobacter, Cupriavidus, Hafnia, Rahnella, Serratia, and Yersinia were isolated from the water samples. Conclusions The results of this study suggest that consumption of unchlorinated drinking water could represent a notable risk to the health of consumers. As such, there is need for continuous monitoring of these water sources and to establish standards. PMID:22216417
Assessing the need to disinfect Hawaii`s groundwater sources under the groundwater disinfection rule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fujioka, R.; Borthakur, P.; Yoneyama, B.
1996-11-01
The Honolulu Board of Water Supply (BWS) is the public water supplier for the island of Oahu which comprises approximately 80% of the population in the state of Hawaii. Today, nearly 100% of the approximately 150 mgd of water provided by the BWS is categorized as groundwater. Historically and up to 1990, the BWS was able to meet the existing coliform drinking water standard even while distributing groundwater to the public without routine disinfection. There has never been any evidence of water borne disease transmission by the distribution system. In fact, one of the major complaints of the public concernsmore » the chlorine taste of the drinking water following spot chlorination during pipe repairs or in reservoir tanks that occasionally become positive for coliform. The most likely source of coliform contamination of reservoir tanks was determined to be the vents of the tanks which are required to allow the water level to rise and fall but which represent sites where external contamination (dust, insects) could enter the tank. It has been a tradition of the BWS to serve safe, good tasting, unchlorinated water to its consumers.« less
NASA Astrophysics Data System (ADS)
SHI, J.
2014-12-01
Climate change is expected to have a significant impact on flooding in the UK, inducing more intense and prolonged storms. Frequent flooding due to climate change already exacerbates catchment water quality. Land use is another contributing factor to poor water quality. For example, the move to intensive farming could cause an increase in faecal coliforms entering the water courses. In an effort to understand better the effects on water quality from land use and climate change, the hydrological and estuarine processes are being modelled using SWAT (Soil and Water Assessment Tool), linked to a 2-D hydrodynamic model DIVAST(Depth Integrated Velocity and Solute Transport). The coupled model is able to quantify how much of each pollutant from the catchment reaches the harbour and the impact on water quality within the harbour. The work is focused on the transportation and decay of faecal coliforms from agricultural runoff into the rivers Frome and Piddle in the UK. The impact from the agricultural land use and activities on the catchment river hydrology and water quality are evaluated. The coupled model calibration and validation showed the good model performance on flow and faecal coliform in the watershed and estuary.
Eckner, Karl F.
1998-01-01
A total of 338 water samples, 261 drinking water samples and 77 bathing water samples, obtained for routine testing were analyzed in duplicate by Swedish standard methods using multiple-tube fermentation or membrane filtration and by the Colilert and/or Enterolert methods. Water samples came from a wide variety of sources in southern Sweden (Skåne). The Colilert method was found to be more sensitive than Swedish standard methods for detecting coliform bacteria and of equal sensitivity for detecting Escherichia coli when all drinking water samples were grouped together. Based on these results, Swedac, the Swedish laboratory accreditation body, approved for the first time in Sweden use of the Colilert method at this laboratory for the analysis of all water sources not falling under public water regulations (A-krav). The coliform detection study of bathing water yielded anomalous results due to confirmation difficulties. E. coli detection in bathing water was similar by both the Colilert and Swedish standard methods as was fecal streptococcus and enterococcus detection by both the Enterolert and Swedish standard methods. PMID:9687478
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skaggs, B.E.
1995-07-01
The Environmental Protection Agency staff published the final storm water regulation on November 16, 1990. The storm water regulation is included in the National Pollutant Discharge Elimination System (NPDES) regulations. It specifies the permit application requirements for certain storm water discharges such as industrial activity or municipal separate storm sewers serving populations of 100,000 or greater. Storm water discharge associated with industrial activity is discharge from any conveyance used for collecting and conveying storm water that is directly related to manufacturing, processing, or raw material storage areas at an industrial plant. Quantitative testing data is required for these discharges. Anmore » individual storm water permit application was completed and submitted to Tennessee Department of Environment and Conservation (TDEC) personnel in October 1992. After reviewing this data in the permit application, TDEC personnel expressed concern with the fecal coliform levels at many of the outfalls. The 1995 NPDES Permit (Part 111-N, page 44) requires that an investigation be conducted to determine the validity of this data. If the fecal coliform data is valid, the permit requires that a report be submitted indicating possible causes and proposed corrective actions.« less