Colonoscope navigation system using colonoscope tracking method based on line registration
NASA Astrophysics Data System (ADS)
Oda, Masahiro; Kondo, Hiroaki; Kitasaka, Takayuki; Furukawa, Kazuhiro; Miyahara, Ryoji; Hirooka, Yoshiki; Goto, Hidemi; Navab, Nassir; Mori, Kensaku
2014-03-01
This paper presents a new colonoscope navigation system. CT colonography is utilized for colon diagnosis based on CT images. If polyps are found while CT colonography, colonoscopic polypectomy can be performed to remove them. While performing a colonoscopic examination, a physician controls colonoscope based on his/her experience. Inexperienced physicians may occur complications such as colon perforation while colonoscopic examinations. To reduce complications, a navigation system of colonoscope while performing the colonoscopic examinations is necessary. We propose a colonoscope navigation system. This system has a new colonoscope tracking method. This method obtains a colon centerline from a CT volume of a patient. A curved line (colonoscope line) representing the shape of colonoscope inserted to the colon is obtained by using electromagnetic sensors. A coordinate system registration process that employs the ICP algorithm is performed to register the CT and sensor coordinate systems. The colon centerline and colonoscope line are registered by using a line registration method. The position of the colonoscope tip in the colon is obtained from the line registration result. Our colonoscope navigation system displays virtual colonoscopic views generated from the CT volumes. A viewpoint of the virtual colonoscopic view is a point on the centerline that corresponds to the colonoscope tip. Experimental results using a colon phantom showed that the proposed colonoscope tracking method can track the colonoscope tip with small tracking errors.
A hydraulically driven colonoscope.
Coleman, Stuart A; Tapia-Siles, Silvia C; Pakleppa, Markus; Vorstius, Jan B; Keatch, Robert P; Tang, Benjie; Cuschieri, Alfred
2016-10-01
Conventional colonoscopy requires a high degree of operator skill and is often painful for the patient. We present a preliminary feasibility study of an alternative approach where a self-propelled colonoscope is hydraulically driven through the colon. A hydraulic colonoscope which could be controlled manually or automatically was developed and assessed in a test bed modelled on the anatomy of the human colon. A conventional colonoscope was used by an experienced colonoscopist in the same test bed for comparison. Pressures and forces on the colon were measured during the test. The hydraulic colonoscope was able to successfully advance through the test bed in a comparable time to the conventional colonoscope. The hydraulic colonoscope reduces measured loads on artificial mesenteries, but increases intraluminal pressure compared to the colonoscope. Both manual and automatically controlled modes were able to successfully advance the hydraulic colonoscope through the colon. However, the automatic controller mode required lower pressures than manual control, but took longer to reach the caecum. The hydraulic colonoscope appears to be a viable device for further development as forces and pressures observed during use are comparable to those used in current clinical practice.
Longcroft-Wheaton, G; Brown, J; Cowlishaw, D; Higgins, B; Bhandari, P
2012-10-01
The resolution of endoscopes has increased in recent years. Modern Fujinon colonoscopes have a charge-coupled device (CCD) pixel density of 650,000 pixels compared with the 410,000 pixel CCD in standard-definition scopes. Acquiring high-definition scopes represents a significant capital investment and their clinical value remains uncertain. The aim of the current study was to investigate the impact of high-definition endoscopes on the in vivo histology prediction of colonic polyps. Colonoscopy procedures were performed using Fujinon colonoscopes and EPX-4400 processor. Procedures were randomized to be performed using either a standard-definition EC-530 colonoscope or high-definition EC-530 and EC-590 colonoscopes. Polyps of <10 mm were assessed using both white light imaging (WLI) and flexible spectral imaging color enhancement (FICE), and the predicted diagnosis was recorded. Polyps were removed and sent for histological analysis by a pathologist who was blinded to the endoscopic diagnosis. The predicted diagnosis was compared with the histology to calculate the accuracy, sensitivity, and specificity of in vivo assessment using either standard or high-definition scopes. A total of 293 polyps of <10 mm were examined–150 polyps using the standard-definition colonoscope and 143 polyps using high-definition colonoscopes. There was no difference in sensitivity, specificity or accuracy between the two scopes when WLI was used (standard vs. high: accuracy 70% [95% CI 62–77] vs. 73% [95% CI 65–80]; P=0.61). When FICE was used, high-definition colonoscopes showed a sensitivity of 93% compared with 83% for standard-definition colonoscopes (P=0.048); specificity was 81% and 82%, respectively. There was no difference between high- and standard-definition colonoscopes when white light was used, but FICE significantly improved the in vivo diagnosis of small polyps when high-definition scopes were used compared with standard definition.
Zupanc, Christine M; Wallis, Guy M; Hill, Andrew; Burgess-Limerick, Robin; Riek, Stephan; Plooy, Annaliese M; Horswill, Mark S; Watson, Marcus O; de Visser, Hans; Conlan, David; Hewett, David G
2017-07-12
The effectiveness of colonoscopy for diagnosing and preventing colon cancer is largely dependent on the ability of endoscopists to fully inspect the colonic mucosa, which they achieve primarily through skilled manipulation of the colonoscope during withdrawal. Performance assessment during live procedures is problematic. However, a virtual withdrawal simulation can help identify and parameterise actions linked to successful inspection, and offer standardised assessments for trainees. Eleven experienced endoscopists and 18 endoscopy novices (medical students) completed a mucosal inspection task during three simulated colonoscopic withdrawals. The two groups were compared on 10 performance metrics to preliminarily assess the validity of these measures to describe inspection quality. Four metrics were related to aspects of polyp detection: percentage of polyp markers found; number of polyp markers found per minute; percentage of the mucosal surface illuminated by the colonoscope (≥0.5 s); and percentage of polyp markers illuminated (≥2.5 s) but not identified. A further six metrics described the movement of the colonoscope: withdrawal time; linear distance travelled by the colonoscope tip; total distance travelled by the colonoscope tip; and distance travelled by the colonoscope tip due to movement of the up/down angulation control, movement of the left/right angulation control, and axial shaft rotation. Statistically significant experienced-novice differences were found for 8 of the 10 performance metrics (p's < .005). Compared with novices, experienced endoscopists inspected more of the mucosa and detected more polyp markers, at a faster rate. Despite completing the withdrawals more quickly than the novices, the experienced endoscopists also moved the colonoscope more in terms of linear distance travelled and overall tip movement, with greater use of both the up/down angulation control and axial shaft rotation. However, the groups did not differ in the number of polyp markers visible on the monitor but not identified, or movement of the left/right angulation control. All metrics that yielded significant group differences had adequate to excellent internal consistency reliability (α = .79 to .90). These systematic differences confirm the potential of the simulated withdrawal task for evaluating inspection skills and strategies. It may be useful for training, and assessment of trainee competence.
Recording forces exerted on the bowel wall during colonoscopy: in vitro evaluation.
Dogramadzi, S; Virk, G S; Bell, G D; Rowland, R S; Hancock, J
2005-12-01
A novel system for distributed force measurement between the bowel wall and the shaft of a colonoscope is presented. The system, based on the piezoresistive method, involves the integration of soft miniature transducers to a colonoscope to enable a wide range of forces to be sensed. The attached sensing sheath does not restrict the propulsion of the colonoscope nor notably alter its flexibility. The addition of the sensor sheath increases the colonoscope diameter by 15-20% depending on the type of the colonoscope (adult or paediatric). The transducer's accuracy is +/-20 grammes if it is not subjected to extensive static forces. Under large static force conditions the errors may increase to +/-50 grammes. The tactile force measuring sensors have provided preliminary results from experiments on a model of the large bowel. The force measurements confirm the predictions on the location and magnitude of the forces and that most of the forces are exerted whilst the instrument is looping. Copyright 2005 John Wiley & Sons, Ltd.
Colonoscopy tutorial software made with a cadaver's sectioned images.
Chung, Beom Sun; Chung, Min Suk; Park, Hyung Seon; Shin, Byeong-Seok; Kwon, Koojoo
2016-11-01
Novice doctors may watch tutorial videos in training for actual or computed tomographic (CT) colonoscopy. The conventional learning videos can be complemented by virtual colonoscopy software made with a cadaver's sectioned images (SIs). The objective of this study was to assist colonoscopy trainees with the new interactive software. Submucosal segmentation on the SIs was carried out through the whole length of the large intestine. With the SIs and segmented images, a three dimensional model was reconstructed. Six-hundred seventy-one proximal colonoscopic views (conventional views) and corresponding distal colonoscopic views (simulating the retroflexion of a colonoscope) were produced. Not only navigation views showing the current location of the colonoscope tip and its course, but also, supplementary description views were elaborated. The four corresponding views were put into convenient browsing software to be downloaded free from the homepage (anatomy.co.kr). The SI colonoscopy software with the realistic images and supportive tools was available to anybody. Users could readily notice the position and direction of the virtual colonoscope tip and recognize meaningful structures in colonoscopic views. The software is expected to be an auxiliary learning tool to improve technique and related knowledge in actual and CT colonoscopies. Hopefully, the software will be updated using raw images from the Visible Korean project. Copyright © 2016 Elsevier GmbH. All rights reserved.
Quality assurance and gastrointestinal endoscopy: an audit of 500 colonoscopic procedures.
Denis, Bernard; Weiss, Anne-Marie; Peter, André; Bottlaender, Jacques; Chiappa, Pascale
2004-12-01
The aim of this study was to assess the quality of colonoscopic procedures in our endoscopy unit with the goal of improving performance. We prospectively audited 500 consecutive colonoscopic procedures and assessed sixty-two process or outcome indicators for each procedure. Most of the measured indicators were within standard limits: cecal intubation rate (92%), inadequate bowel preparations (24%), inappropriate procedures (9.7%), normal procedures (54%), yield for neoplasia (32%), morbidity (0.4%), and overall patient satisfaction (95.8%). Some indicators were outside standard limits suggesting our practices should be modified: endoscopy withdrawal time less than 6 minutes (78%), forceps removal of polyps (31%), resected polyps not recovered for pathological examination (12%), adenomas with villous elements (22%), patients unsatisfied because of time spent waiting for the procedure (19%), patients unsatisfied because of inadequate explanations (10%). There was no standard for a few indicators: patient discomfort (6.9%), diagnostic success (89%), therapeutic success (92%). Three new indicators were proposed: proportion of patients aged<50 years, number of normal colonoscopic procedures to perform to detect one advanced adenoma or cancer, and proportion of colonoscopic procedures causing discomfort. The diagnostic yield of colonoscopy was dependent on age, gender, indication and appropriateness of indication but not on the prescriber. This audit allowed us to evaluate our endoscopic practices and to detect certain shortcomings and deviations from standards. It enabled us to change some of our practices with the goal of improving the quality of our colonoscopic procedures.
Ingram, Jackie; Gaines, Peggy; Kite, Roberta; Morgan, Marcia; Spurling, Sheila; Winsett, Rebecca P
2013-01-01
The purpose of this study was to examine bacterial growth in colonoscopes in a series of graduated shelf times. There is no conclusive evidence on the length of time colonoscopes can be safely stored before requiring redisinfection. Standards for processing scopes after use are described and supported by the professional organizations of gastroenterology and infection control; however, shelf life varies from 3 to 5 days and most recommendations are based on clinical consensus. In this study, four colonoscopes were used in a clinical procedure, underwent automated high-level disinfection with 2.6% buffered glutaraldehyde, and cultured after 3, 5, 7, 14, 21, 28, 42, and 56 days of shelf time. Two investigators collected all the cultures after interrater reliability was established. Cultures were processed in the microbiology laboratory. No medically significant growth was detected at any of the culture points. At Day 14 and Day 42, one of four scopes grew fewer than two colony-forming units of a medically insignificant bacterium. Using professional standards for high-level disinfection growth was suppressed for up to 8 weeks. Further evidence to assess fungal or viral growth is needed to be able to make suggestions for colonoscope shelf life.
Improved haptic interface for colonoscopy simulation.
Woo, Hyun Soo; Kim, Woo Seok; Ahn, Woojin; Lee, Doo Yong; Yi, Sun Young
2007-01-01
This paper presents an improved haptic interface of the KAIST-Ewha colonoscopy simulator II. The haptic interface enables the distal portion of the colonoscope to be freely bent while guaranteeing enough workspace and reflective forces for colonoscopy simulation. Its force-torque sensor measures profiles of the user. Manipulation of the colonoscope tip is monitored by four deflection sensors, and triggers computation to render accurate graphic images corresponding to the angle knob rotation. Tack switches are attached on the valve-actuation buttons of the colonoscope to simulate air-injection or suction, and the corresponding deformation of the colon.
Fabrication of An Inexpensive but Effective Colonoscopic Simulator.
Jones, Mark W; Deere, Matthew J; Harris, Justin R; Chen, Anthony J; Henning, Werner H
2017-01-01
Because of increasing requirements for simulator training before actual clinical endoscopies, the demand for realistic, inexpensive endoscopic simulators is increasing. We describe the steps involved in the design and fabrication of an effective and realistic mechanical colonoscopic simulator.
Johnstone, M S; Moug, S J
2014-05-01
Colonoscopy is essential for accurate pre-operative colorectal tumour localisation, but its accuracy for localisation remains undetermined due to limitations of previous work. This study aimed to establish the accuracy of colonoscopic localisation and to determine how frequently inaccuracy results in altered surgical management. A prospective, multi-centred, powered observational study recruited 79 patients with colorectal tumours that underwent curative surgical resection. Patient and colonoscopic factors were recorded. Pre-operative colonoscopic and radiological lesion localisations were compared to intra-operative localisation using pre-defined anatomical bowel segments to determine accuracy, with changes in planned surgical management documented. Colonoscopy accurately located the colorectal tumour in 64/79 patients (81%). Five out of 15 inaccurately located patients required on-table alteration in planned surgical management. Pre-operative imaging was unable to visualise the primary tumour in 23.1% of cases, a finding that was more prevalent amongst bowel screener patients compared to symptomatic patients (45.8% vs. 13%; p = 0.003). Colonoscopic lesion localisation is inaccurate in 19.0% of cases and occurred throughout the colon with a change in on-table surgical management in 6.3%. With CT unable to visualise lesions in just under a quarter of cases, particularly in the screening population, preoperative localisation is heavily reliant on colonoscopy.
Shaikhani, Mohammad A R; Husein, Hiwa A B; Karbuli, Taha A; Mohamed, Mohamed Abdulrahman
2013-09-01
Lower gastrointestinal bleeding (LGIB) along with intestinal perforation is a well-known complication of typhoid fever. Reports of colonoscopic appearance and intervention of typhoid perforation involve only few cases. This series reports the colonoscopic findings and the role of colonoscopic hemostatic interventions in controlling the bleeding ileocolonic lesions. During the typhoid fever outbreak in Sulaymaniyah City in Iraqi Kurdistan Region, we received 52 patients with LGIB manifesting as fresh bleeding per rectum or melena. We performed total colonoscopy with ileal intubation for all cases. The findings were recorded and endoscopic hemostatic intervention with adrenaline-saline injection and argon plasma coagulation was applied to actively bleeding lesion. These patients were young, 11-30 years of age, with female preponderance. Blood culture was positive in 50 %. Colonoscopic findings were mostly located in the ileocecal region, although other areas of the colon were involved in many cases. Twenty-four percent of the cases required endoscopic hemostatic intervention by adrenaline injection with argon plasma coagulation which was effective in all patients except one who died in spite of surgical intervention in addition of endoscopic hemostasis. Dual endoscopic hemostatic intervention can be a safe and effective management option for patients with LGIB due to typhoid fever.
Nakao, Frank Shigueo; Araújo, Isabella Saraiva; Ornellas, Laura Cotta; Cury, Marcelo de Sousa; Ferrari, Angelo Paulo
2002-01-01
Magnification colonoscopy and contrast chromoscopy with indigo carmine dye solution have been used to differentiate neoplastic polyps (adenomas and adenocarcinomas) from non-neoplastic (hyperplastic, inflammatory, juvenile) in an attempt to obviate endoscopic polypectomy. On the other hand, little published information exists concerning conventional video colonoscopes and chromoscopy for polyp histology prediction. Aim - To assess usefullness of conventional video colonoscopes and contrast chromoscopy with indigo carmine solution for differential diagnosis of colon polyps. In a routine colonoscopy series, we performed chromoscopy with conventional video colonoscopes before endoscopic excision of detected polyps. If a sulcus pattern was observed on the surface of the lesion, it was classified as neoplastic. Polyps were classified as non-neoplastic if no sulcus was detected on its surface. These observations were then compared with histology. In the study period (18 months), we detected 133 polyps in 53 patients. We were able to compare results of histology and chromoscopy in 126 lesions. The sensitivity, specificity, diagnostic accuracy, negative predictive value, and positive predictive value were 56,4%, 79,2%, 65,1%, 52,8%, and 81,5%, respectively. On the base of the presented data, we concluded that conventional video colonoscopes and contrast chromoscopy with indigo carmine solution is not a good technique for differential diagnosis of colon polyps.
Sjöström, Olle; Lindholm, Lars; Tavelin, Björn; Melin, Beatrice
2016-10-01
Although colonoscopic surveillance is recommended both for individuals with known hereditary colorectal cancer (HCRC) syndromes and those with a more moderate familial colorectal cancer (FCRC) history, the evidence for the benefits of surveillance is limited and surveillance practices vary. This study evaluates the preventive effect for individuals with a family history of CRC of decentralized colonoscopic surveillance with the guidance of a cancer prevention clinic. We performed a population based prospective study of 261 patients with HCRC or FCRC, recorded in the colonoscopic surveillance registry at the Cancer genetics clinic, University Hospital of Umeå, Sweden. Colonoscopic surveillance was conducted every second (HCRC) or fifth (FCRC) year at local hospitals in Northern Sweden. Main outcome measures were findings of high-risk adenomas (HRA) or CRC, and patient compliance to surveillance. Estimations of the expected numbers of CRC without surveillance were made. During a total of 1256 person years of follow-up, one case of CRC was found. The expected numbers of cancers in the absence of surveillance was between 9.5 and 10.5, resulting in a standardized incidence ratio, observed versus expected cases of CRC, between 0.10 (CI 95 % 0.0012-0.5299) and 0.11 (CI 95 % 0.0014-0.5857). No CRC mortality was reported, but three patients needed surgical intervention. HRA were found in 5.9 % (14/237) of the initial and in 3.4 % (12/356) of the follow-up colonoscopies. Patient compliance to the surveillance program was 90 % as 597 of the planned 662 colonoscopies were performed. The study concludes that colonoscopic surveillance with high patient compliance to the program is effective in preventing CRC when using a decentralized method for colonoscopy surveillance with the guidance of a cancer prevention clinic.
Vinsard, Daniela Guerrero; Kandel, Pujan; Mejia Perez, Lady Katherine; Bingham, Russell L.; Lennon, Ryan J.; Woodward, Timothy A.; Gomez, Victoria; Raimondo, Massimo; Bouras, Ernest P.; Wallace, Michael B.
2018-01-01
Background and study aims Risk factors for colorectal adenoma recurrence after endoscopic mucosal resection (EMR) have been well documented. We assessed the efficacy of the newer 190 colonoscope versus the standard 180 colonoscope for complete resection of lateral spreading lesions. Patients and methods A single-center, retrospective study of patients who underwent EMR with Olympus 180 or 190 colonoscopes from January 1, 2010 to September 30, 2016. We included patients with lesions ≥ 20 mm and surveillance colonoscopy (SC1) after index EMR. A propensity score approach with inverse probability weighting was used to control for potential confounders. A secondary aim was to identify risk factors for recurrence and assess the applicability of the Sydney EMR recurrence tool (SERT) by grading each lesion of our cohort and analyzing associations with recurrence. Results Two hundred ninety-one lesions met inclusion criteria for the study. Odds ratio (OR) for recurrence with the 190 colonoscope was 1.06 ( P = .85). Adenoma size ( P = .02) and use of argon plasma coagulation (APC; P < .001) were risk factors for recurrence. Lesions with SERT scores > 0 had a higher recurrence risk during follow-up (32 % vs 21 %; OR 1.71; P = .05). Lesions with SERT scores = 0 reached a plateau for recurrence at 12 and 18 months in Kaplan-Meier curves. Conclusions The use of 190 colonoscopes did not measurably affect adenoma recurrence at SC1. Recurrence was associated with adenoma size, complementary APC for resection, and SERT scores > 0. Lesions with SERT scores = 0 that remain negative for recurrence at 18 months may return to routine surveillance. PMID:29423433
Xie, Qin; Chen, Bin; Liu, Liu; Gan, Huatian
2012-10-24
The variable-stiffness colonoscope (VSC) appears to have advantages over the standard adult colonoscope (SAC), although data are conflicting. To provide a comprehensive up-to-date review, we conducted a meta-analysis to compare the efficacies of the VSC and SAC. Electronic databases, including PubMed, EMBASE, the Cochrane library and the Science Citation Index, were searched to retrieve relevant trials. In addition, meeting abstracts and the reference lists of retrieved articles were reviewed for further relevant studies. Eight randomized controlled trials (RCTs), enrolling a total of 2033 patients, were included in the meta-analysis. There was no significant heterogeneity among these studies. The cecal intubation rate was higher with the use of VSC (RR = 1.03, 95% CI 1.01 to 1.06, 8 RCTs). The VSC was also associated with fewer position changes made during colonoscopy. Time to cecal intubation was similar with VSC and SAC (WMD -0.54, 95% CI -1.40 to 0.32) but shorter in subgroup analysis with the use of VSC (WMD = -1.36, 95% CI -2.29 to -0.43). Sedation dose used with the two types of instruments showed no evidence of differences either. For all trials, only patients were blinded because of the nature of the interventions. Use of the VSC significantly improved the cecal intubation rate and reduced ancillary maneuvers made during the procedure. Cecal intubation time was similar for the two colonoscope types over all trials, whereas a shortened time with the use of the adult VSC was seen in subgroup analysis.
2012-01-01
Background The variable-stiffness colonoscope (VSC) appears to have advantages over the standard adult colonoscope (SAC), although data are conflicting. To provide a comprehensive up-to-date review, we conducted a meta-analysis to compare the efficacies of the VSC and SAC. Methods Electronic databases, including PubMed, EMBASE, the Cochrane library and the Science Citation Index, were searched to retrieve relevant trials. In addition, meeting abstracts and the reference lists of retrieved articles were reviewed for further relevant studies. Results Eight randomized controlled trials (RCTs), enrolling a total of 2033 patients, were included in the meta-analysis. There was no significant heterogeneity among these studies. The cecal intubation rate was higher with the use of VSC (RR = 1.03, 95% CI 1.01 to 1.06, 8 RCTs). The VSC was also associated with fewer position changes made during colonoscopy. Time to cecal intubation was similar with VSC and SAC (WMD −0.54, 95% CI −1.40 to 0.32) but shorter in subgroup analysis with the use of VSC (WMD = −1.36, 95% CI −2.29 to −0.43). Sedation dose used with the two types of instruments showed no evidence of differences either. For all trials, only patients were blinded because of the nature of the interventions. Conclusion Use of the VSC significantly improved the cecal intubation rate and reduced ancillary maneuvers made during the procedure. Cecal intubation time was similar for the two colonoscope types over all trials, whereas a shortened time with the use of the adult VSC was seen in subgroup analysis. PMID:23095461
New vision based navigation clue for a regular colonoscope's tip
NASA Astrophysics Data System (ADS)
Mekaouar, Anouar; Ben Amar, Chokri; Redarce, Tanneguy
2009-02-01
Regular colonoscopy has always been regarded as a complicated procedure requiring a tremendous amount of skill to be safely performed. In deed, the practitioner needs to contend with both the tortuousness of the colon and the mastering of a colonoscope. So, he has to take the visual data acquired by the scope's tip into account and rely mostly on his common sense and skill to steer it in a fashion promoting a safe insertion of the device's shaft. In that context, we do propose a new navigation clue for the tip of regular colonoscope in order to assist surgeons over a colonoscopic examination. Firstly, we consider a patch of the inner colon depicted in a regular colonoscopy frame. Then we perform a sketchy 3D reconstruction of the corresponding 2D data. Furthermore, a suggested navigation trajectory ensued on the basis of the obtained relief. The visible and invisible lumen cases are considered. Due to its low cost reckoning, such strategy would allow for the intraoperative configuration changes and thus cut back the non-rigidity effect of the colon. Besides, it would have the trend to provide a safe navigation trajectory through the whole colon, since this approach is aiming at keeping the extremity of the instrument as far as possible from the colon wall during navigation. In order to make effective the considered process, we replaced the original manual control system of a regular colonoscope by a motorized one allowing automatic pan and tilt motions of the device's tip.
Endoscopic innovations to increase the adenoma detection rate during colonoscopy
Dik, Vincent K; Moons, Leon MG; Siersema, Peter D
2014-01-01
Up to a quarter of polyps and adenomas are missed during colonoscopy due to poor visualization behind folds and the inner curves of flexures, and the presence of flat lesions that are difficult to detect. These numbers may however be conservative because they mainly come from back-to-back studies performed with standard colonoscopes, which are unable to visualize the entire mucosal surface. In the past several years, new endoscopic techniques have been introduced to improve the detection of polyps and adenomas. The introduction of high definition colonoscopes and visual image enhancement technologies have been suggested to lead to better recognition of flat and small lesions, but the absolute increase in diagnostic yield seems limited. Cap assisted colonoscopy and water-exchange colonoscopy are methods to facilitate cecal intubation and increase patients comfort, but show only a marginal or no benefit on polyp and adenoma detection. Retroflexion is routinely used in the rectum for the inspection of the dentate line, but withdrawal in retroflexion in the colon is in general not recommended due to the risk of perforation. In contrast, colonoscopy with the Third-Eye Retroscope® may result in considerable lower miss rates compared to standard colonoscopy, but this technique is not practical in case of polypectomy and is more time consuming. The recently introduced Full Spectrum Endoscopy™ colonoscopes maintains the technical capabilities of standard colonoscopes and provides a much wider view of 330 degrees compared to the 170 degrees with standard colonoscopes. Remarkable lower adenoma miss rates with this new technique were recently demonstrated in the first randomized study. Nonetheless, more studies are required to determine the exact additional diagnostic yield in clinical practice. Optimizing the efficacy of colorectal cancer screening and surveillance requires high definition colonoscopes with improved virtual chromoendoscopy technology that visualize the whole colon mucosa while maintaining optimal washing, suction and therapeutic capabilities, and keeping the procedural time as low and patient discomfort as optimal as possible. PMID:24605019
Ni, Yu-Fei; Li, Jun; Wang, Ben-Fu; Jiang, Song-He; Chen, Yi; Zhang, Wei-Feng; Lian, Qing-Quan
2009-10-01
To observe the effect of electroacupuncture (EA) on bispectral index (BIS) and plasma beta-endorphin (beta-EP) level in patients undergoing colonoscopy. Sixty patients were equally randomized into EA group and control group with 30 cases in each. EA (2 Hz/100 Hz, 4-6 V) was applied to the right Zusanli (ST 36) and Shangjuxu (ST 37), and the left Yinlingquan (SP 9), Sanyinjiao (SP 6) and bilateral Hegu (LI 4) respectively 30 min before colonoscopy. The mean arterial pressure (MAP), heart rate (HR) and BIS in two groups were continuously monitored during the study. Plasma beta-EP concentration was detected by radioimmunoassay. The patient's adverse reactions (including pain, satisfaction degree, etc.) were evaluated by visual analog scale (VAS) and verbal stress scale (VSS). Self-comparison showed that MAP and HR in control group increased significantly during colonoscope's splenic flexure passing (P<0.05). Whereas the 2 indexes in EA group had no significant changes during colonoscope insertion, and its splenic flexure passing, hepatic flexure passing and post-enteroscopy (P>0.05). Comparison between two groups showed that MAP at the time-point of colonoscope insertion, and HR at the time-point of colonoscope's splenic flexure passing in EA group were significantly lower than those in control group (P<0.05). BIS values of EA group were significantly lower than those of control group at different time-points after colonoscope insertion (P<0.01). Plasma beta-EP concentrations at the time-points of colonoscope's hepatic flexure passing and post-enteroscopy were evidently increased in both groups in comparison with pre-enteroscopy (P<0.01), and beta-EP was significantly lower in EA group than that in control group at the time-point of colonoscope's hepatic flexure passing (P<0.05). The dosage of Midazolam used for conscious-sedation and the scores of VAS and VSS were also considerably lower in EA group than those in control group (P<0.05, P<0.01). No significant differences were found between two groups in the adverse reactions as dizziness, nausea, vomiting and abdominal pain, but the patients' satisfaction degree in EA group was evidently higher than that in control group (P<0.05). Acupuncture analgesia can effectively lower the colonoscopy patients' BIS value and plasma beta-EP level, meaning attenuation of the patients' stress responses during colonoscopy after EA.
Evaluation of the tip-bending response in clinically used endoscopes.
Rozeboom, Esther D; Reilink, Rob; Schwartz, Matthijs P; Fockens, Paul; Broeders, Ivo A M J
2016-04-01
Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses.
Othman, M O; Bradley, A G; Choudhary, A; Hoffman, R M; Roy, P K
2009-01-01
The variable stiffness colonoscope (VSC) may have theoretical advantages over standard adult colonoscopes (SACs), though data are conflicting. We conducted a meta-analysis to compare the efficacies of the VSC and SAC. We searched Medline (1966 - 2008) and abstracts of gastroenterology scientific meetings in the 5 years to February 2008, only for randomized clinical trials (RCTs) of adult patients. Trial quality was assessed using the Delphi list. In a meta-analysis with a fixed effects model, cecal intubation rates, cecal intubation times, abdominal pain scores, sedation used, and use of ancillary maneuvers, were compared in separate analyses, using weighted mean differences (WMDs), standardized mean differences (SMDs), or odds ratios (ORs). Seven RCTs satisfied the inclusion criteria (1923 patients), four comparing VSC with SAC procedures in adults, and three evaluating the pediatric VSC. There was no significant heterogeneity among the studies. The overall trial quality was adequate. Cecal intubation rate was higher with the use of VSC (OR = 2.08, 95 % confidence interval [CI] 1.29 to 3.36). The VSC was associated with lower abdominal pain scores and a decreased need for sedation during colonoscopy. Cecal intubation time was similar for the two colonscope types (WMD = - 0.21 minutes, 95 % CI - 0.85 to 0.43). Because of the nature of the intervention no studies were blinded. There was no universal method for using the VSC. Compared with the SAC, VSC use was associated with a higher cecal intubation rate, less abdominal pain, and decreased need for sedation. However, cecal intubation times were similar for the two colonoscope types.
Evaluation of the tip-bending response in clinically used endoscopes
Rozeboom, Esther D.; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo A. M. J.
2016-01-01
Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. Materials and methods: We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Results: Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. Conclusion: This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses. PMID:27092330
Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm.
Woo, Jaehong; Choi, Jae Hyuk; Seo, Jong Tae; Kim, Tae Il; Yi, Byung Ju
2017-01-01
Colonoscopy is one of the most effective diagnostic and therapeutic tools for colorectal diseases. We aim to propose a master-slave robotic colonoscopy that is controllable in remote site using conventional colonoscopy. The master and slave robot were developed to use conventional flexible colonoscopy. The robotic colonoscopic procedure was performed using a colonoscope training model by one expert endoscopist and two unexperienced engineers. To provide the haptic sensation, the insertion force and the rotating torque were measured and sent to the master robot. A slave robot was developed to hold the colonoscopy and its knob, and perform insertion, rotation, and two tilting motions of colonoscope. A master robot was designed to teach motions of the slave robot. These measured force and torque were scaled down by one tenth to provide the operator with some reflection force and torque at the haptic device. The haptic sensation and feedback system was successful and helpful to feel the constrained force or torque in colon. The insertion time using robotic system decreased with repeated procedures. This work proposed a robotic approach for colonoscopy using haptic feedback algorithm, and this robotic device would effectively perform colonoscopy with reduced burden and comparable safety for patients in remote site.
A Challenging Case of Acute Mercury Toxicity
Alghoula, Faysal; Holewinski, Christopher
2018-01-01
Background Mercury exists in multiple forms: elemental, organic, and inorganic. Its toxic manifestations depend on the type and magnitude of exposure. The role of colonoscopic decompression in acute mercury toxicity is still unclear. We present a case of acute elemental mercury toxicity secondary to mercury ingestion, which markedly improved with colonoscopic decompression. Clinical Case A 54-year-old male presented to the ED five days after ingesting five ounces (148 cubic centimeters) of elemental mercury. Examination was only significant for a distended abdomen. Labs showed elevated serum and urine mercury levels. An abdominal radiograph showed radiopaque material throughout the colon. Succimer and laxatives were initiated. The patient had recurrent bowel movements, and serial radiographs showed interval decrease of mercury in the descending colon with interval increase in the cecum and ascending colon. Colonoscopic decompression was done successfully. The colon was evacuated, and a repeat radiograph showed decreased hyperdense material in the colon. Three months later, a repeat radiograph showed no hyperdense material in the colon. Conclusion Ingested elemental mercury can be retained in the colon. Although there are no established guidelines for colonoscopic decompression, our patient showed significant improvement. We believe further studies on this subject are needed to guide management practices. PMID:29559996
Haptic interface of the KAIST-Ewha colonoscopy simulator II.
Woo, Hyun Soo; Kim, Woo Seok; Ahn, Woojin; Lee, Doo Yong; Yi, Sun Young
2008-11-01
This paper presents an improved haptic interface for the Korea Advanced Institute of Science and Technology Ewha Colonoscopy Simulator II. The haptic interface enables the distal portion of the colonoscope to be freely bent while guaranteeing sufficient workspace and reflective forces for colonoscopy simulation. Its force-torque sensor measures the profiles of the user. Manipulation of the colonoscope tip is monitored by four deflection sensors and triggers computations to render accurate graphic images corresponding to the rotation of the angle knob. Tack sensors are attached to the valve-actuation buttons of the colonoscope to simulate air injection or suction as well as the corresponding deformation of the colon. A survey study for face validation was conducted, and the result shows that the developed haptic interface provides realistic haptic feedback for colonoscopy simulations.
Evaluation of magnifying colonoscopy in the diagnosis of serrated polyps.
Ishigooka, Shinya; Nomoto, Masahito; Obinata, Nobuyuki; Oishi, Yoshichika; Sato, Yoshinori; Nakatsu, Satoko; Suzuki, Midori; Ikeda, Yoshiko; Maehata, Tadateru; Kimura, Tomoaki; Watanabe, Yoshiyuki; Nakajima, Takashi; Yamano, Hiro-o; Yasuda, Hiroshi; Itoh, Fumio
2012-08-28
To elucidate the colonoscopic features of serrated lesions of the colorectum using magnifying colonoscopy. Broad division of serrated lesions of the colorectum into hyperplastic polyps (HPs), traditional serrated adenomas (TSAs), and sessile serrated adenomas/polyps (SSA/Ps) has been proposed on the basis of recent molecular biological studies. However, few reports have examined the colonoscopic features of these divisions, including magnified colonoscopic findings. This study examined 118 lesions excised in our hospital as suspected serrated lesions after magnified observation between January 2008 and September 2011. Patient characteristics (sex, age), conventional colonoscopic findings (location, size, morphology, color, mucin) and magnified colonoscopic findings (pit pattern diagnosis) were interpreted by five colonoscopists with experience in over 1000 colonoscopies, and were compared with histopathological diagnoses. The pit patterns were categorized according to Kudo's classification, but a more detailed investigation was also performed using the subclassification [type II-Open (type II-O), type II-Long (type II-L), or type IV-Serrated (type IV-S)] proposed by Kimura T and Yamano H. Lesions comprised 23 HPs (23/118: 19.5%), 39 TSAs (39/118: 33.1%: with cancer in one case), 50 SSA/Ps (50/118: 42.4%: complicated with cancer in three cases), and six others (6/118: 5.1%). We excluded six others, including three regular adenomas, one hamartoma, one inflammatory polyp, and one juvenile polyp for further analysis. Conventional colonoscopy showed that SSA/Ps were characterized as larger in diameter than TSAs and HPs (SSA/P vs HP, 13.62 ± 8.62 mm vs 7.74 ± 3.24 mm, P < 0.001; SSA/Ps vs TSA, 13.62 ± 8.62 mm vs 9.89 ± 5.73 mm, P < 0.01); common in the right side of the colon [HPs, 30.4% (7/23): TSAs, 20.5% (8/39): SSA/P, 84.0% (42/50), P < 0.001]; flat-elevated lesion [HPs, 30.4% (7/23): TSAs, 5.1% (2/39): SSA/Ps, 90.0% (45/50), P < 0.001]; normal-colored or pale imucosa [HPs, 34.8% (8/23): TSAs, 10.3% (4/39): SSA/Ps, 80% (40/50), P < 0.001]; and with large amounts of mucin [HPs, 21.7% (5/23): TSAs, 17.9% (7/39): SSA/Ps, 72.0% (36/50), P < 0.001]. In magnified colonoscopic findings, 17 lesions showed either type II pit pattern alone or partial type II pit pattern as the basic architecture, with 14 HPs (14/17, 70.0%) and 3 SSA/Ps. Magnified colonoscopy showed the type II-O pit pattern as characteristic of SSA/Ps [sensitivity 83.7% (41/49), specificity 85.7% (54/63)]. Cancer was also present in three lesions, in all of which a type VI pit pattern was also present within the same lesion. There were four HPs and four TSAs each. The type IV-S pit pattern was characteristic of TSAs [sensitivity 96.7% (30/31), specificity 89.9% (72/81)]. Cancer was present in one lesion, in which a type VI pit pattern was also present within the same lesion. In our study, serrated lesions of the colorectum also possessed the features described in previous reports of conventional colonoscopic findings. The pit pattern diagnosis using magnifying colonoscopy, particularly magnified colonoscopic findings using subclassifications of surface architecture, reflected the pathological characteristics of SSA/Ps and TSAs, and will be useful for colonoscopic diagnosis. We suggest that this system could be a good diagnostic tool for SSA/Ps using magnifying colonoscopy.
Bond, Ashley; O'Toole, Paul; Fisher, Gareth; Subramanian, Sreedhar; Haslam, Neil; Probert, Chris; Cox, Trevor; Sarkar, Sanchoy
2017-03-01
Adenoma detection rate (ADR) is the most important quality indicator for screening colonoscopy, due to its association with colorectal cancer outcomes. As a result, a number of techniques and technologies have been proposed that have the potential to improve ADR. The aim of this study was to assess the potential impact of new-generation high-definition (HD) colonoscopy on ADR within the Bowel Cancer Screening Programme (BCSP). This was a retrospective single-center observational study in patients undergoing an index screening colonoscopy. The examination was performed with either standard-definition colonoscopes (Olympus Q240/Q260 series) or HD colonoscopes (Olympus HQ290 EVIS LUCERA ELITE system) with the primary outcome measures of ADR and mean adenoma per procedure (MAP) between the 2 groups. A total of 395 patients (60.5% male, mean age 66.8 years) underwent screening colonoscopy with 45% performed with HD colonoscopes. The cecal intubation rate was 97.5% on an intention-to-treat basis and ADR was 68.6%. ADR with standard-definition was 63.13%, compared with 75.71% with HD (P = .007). The MAP in the HD group was 2.1 (± 2.0), whereas in the standard-definition group it was 1.6 (± 1.8) (P = .01). There was no significant difference in withdrawal time between the 2 groups. In the multivariate regression model, only HD scopes (P = .03) and male sex (P = .04) independently influenced ADR. Olympus H290 LUCERA ELITE HD colonoscopes improved adenoma detection within the moderate-risk population. A 12% improvement in ADR might be expected to increase significantly the protection afforded by colonoscopy against subsequent colorectal cancer mortality. Copyright © 2016 Elsevier Inc. All rights reserved.
Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm
Woo, Jaehong; Choi, Jae Hyuk; Seo, Jong Tae
2017-01-01
Purpose Colonoscopy is one of the most effective diagnostic and therapeutic tools for colorectal diseases. We aim to propose a master-slave robotic colonoscopy that is controllable in remote site using conventional colonoscopy. Materials and Methods The master and slave robot were developed to use conventional flexible colonoscopy. The robotic colonoscopic procedure was performed using a colonoscope training model by one expert endoscopist and two unexperienced engineers. To provide the haptic sensation, the insertion force and the rotating torque were measured and sent to the master robot. Results A slave robot was developed to hold the colonoscopy and its knob, and perform insertion, rotation, and two tilting motions of colonoscope. A master robot was designed to teach motions of the slave robot. These measured force and torque were scaled down by one tenth to provide the operator with some reflection force and torque at the haptic device. The haptic sensation and feedback system was successful and helpful to feel the constrained force or torque in colon. The insertion time using robotic system decreased with repeated procedures. Conclusion This work proposed a robotic approach for colonoscopy using haptic feedback algorithm, and this robotic device would effectively perform colonoscopy with reduced burden and comparable safety for patients in remote site. PMID:27873506
Feasibility of full-spectrum endoscopy: Korea’s first full-spectrum endoscopy colonoscopic trial
Song, Jeong-Yeop; Cho, Youn Hee; Kim, Mi A; Kim, Jeong-Ae; Lee, Chun Tek; Lee, Moon Sung
2016-01-01
AIM: To evaluate the full-spectrum endoscopy (FUSE) colonoscopy system as the first report on the utility thereof in a Korean population. METHODS: We explored the efficacy of the FUSE colonoscopy in a retrospective, single-center feasibility study performed between February 1 and July 20, 2015. A total of 262 subjects (age range: 22-80) underwent the FUSE colonoscopy for colorectal cancer screening, polyp surveillance, or diagnostic evaluation. The cecal intubation success rate, the polyp detection rate (PDR), the adenoma detection rate (ADR), and the diverticulum detection rate (DDR), were calculated. Also, the success rates of therapeutic interventions were evaluated with biopsy confirmation. RESULTS: All patients completed the study and the success rates of cecal and terminal ileal intubation were 100% with the FUSE colonoscope; we found 313 polyps in 142 patients and 173 adenomas in 95. The overall PDR, ADR and DDR were 54.2%, 36.3%, and 25.2%, respectively, and were higher in males, and increased with age. The endoscopists and nurses involved considered that the full-spectrum colonoscope improved navigation and orientation within the colon. No colonoscopy was aborted because of colonoscope malfunction. CONCLUSION: The FUSE colonoscopy yielded a higher PDR, ADR, DDR than did traditional colonoscopy, without therapeutic failure or complications, showing feasible, effective, and safe in this first Korean trial. PMID:26937150
Primary T-cell Lymphoma of the Colon
Son, Hee Jung; Rhee, Poong Lyul; Kim, Jae-Jun; Koh, Kwang Choel; Paik, Seong Woon; Rhee, Jong Chul; Koh, Young Hae
1997-01-01
A 40-year-old woman had been diagnosed with Crohns disease in September 1994, but later examinations revealed a primary T-cell lymphoma of the colon. Colonoscopic and histological examination showed ulcerative lesions simulating Crohns disease involving the entire colon and the terminal ileum, and she was first diagnosed as having Crohns disease. Differential therapeutic strategies, including corticosteroid, had improved the symptoms which were dominated by abdominal pain. When she visited our institute in April 1995, she presented with bloody stool twice a day, 7kg weight loss in a period of six months and a slightly painful abdomen. Colonoscopic finding showed geographic ulceration on the entire colon, especially rectum and terminal ileum. The histologic examination of specimens from colonoscopic biopsy showed primary peripheral T-cell lymphoma of the colon. Any dense lymphocyte infiltrates seen in the biopsy specimens obtained from lesions simulating ulcerative colitis or Crohns disease should be assessed to exclude intestinal lymphoma PMID:9439161
Analysis of a concentric-tube robot design and feasibility for endoscopic deployment
NASA Astrophysics Data System (ADS)
Ponten, Ryan; Black, Caroline B.; Russ, Andrew J.; Rucker, D. Caleb
2017-03-01
An intraluminal endoscopic approach is desirable for most colonoscopic procedures and is growing in favor for other surgeries as tools are enhanced. Flexible robotic manipulators could further enhance the dexterity and precision of commercial endoscopic systems. In this paper, we explore the capabilities of concentric tube robots to work as tool manipulators at the tip of a colonoscope to perform endoscopic submucousal dissection (ESD) and endoscopic full thickness resection (EFTR). We provide an overview of the kinematic modeling of these manipulators, a design of a prototype manipulator and the transmission actuation system. Our analysis examines the workspace and stiffness of these manipulators being controlled at the tip of a colonoscope. We compare the results to reported surgical requirements and propose solutions for enhancing their effectiveness including notching tubes with a larger Young's Modulus. We also determine the resolution and accuracy of the actuation system.
When and why a colonoscopist should discontinue colonoscopy by himself?
Gan, Tao; Yang, Jin-Lin; Wu, Jun-Chao; Wang, Yi-Ping; Yang, Li
2015-07-07
To investigate when and why a colonoscopist should discontinue incomplete colonoscopy by himself. In this cross-sectional study, 517 difficult colonoscope insertions (Grade C, Kudo's difficulty classification) screened from 37800 colonoscopy insertions were collected from April 2004 to June 2014 by three 4(th)-level (Kudo's classification) colonoscopists. The following common factors for the incomplete insertion were excluded: structural obstruction of the colon or rectum, insufficient colon cleansing, discontinuation due to patient's discomfort or pain, severe colon disease with a perforation risk (e.g., severe ischemic colonopathy). All the excluded patients were re-scheduled if permission was obtained from the patients whose intubation had failed. If the repeat intubations were still a failure because of the difficult operative techniques, those patients were also included in this study. The patient's age, sex, anesthesia and colonoscope type were recorded before colonoscopy. During the colonoscopic examination, the influencing factors of fixation, tortuosity, laxity and redundancy of the colon were assessed, and the insertion time (> 10 min or ≤ 10 min) were registered. The insertion time was analyzed by t-test, and other factors were analyzed by univariate and multivariate logistic regression. Three hundred and twenty-two (62.3%) of the 517 insertions were complete in the colonoscope insertion into the ileocecum, but 195 (37.7%) failed in the insertion. Fixation, tortuosity, laxity or redundancy occurred during the colonoscopic examination. Multivariate logistic regression analysis revealed that fixation (OR = 0.06, 95%CI: 0.03-0.16, P < 0.001) and tortuosity (OR = 0.04, 95%CI: 0.02-0.08, P < 0.001) were significantly related to the insertion into the ileocecum in the left hemicolon; multivariate logistic regression analysis also revealed that fixation (OR = 0.16, 95%CI: 0.06-0.39, P < 0.001), tortuosity (OR 0.23, 95%CI: 0.13-0.43, P < 0.001), redundancy (OR = 0.12, 95%CI: 0.05-0.26, P < 0.001) and sex (OR = 0.35, 95%CI: 0.20-0.63, P < 0.001) were significantly related to the insertion into the ileocecum in the right hemicolon. Prolonged insertion time (> 10 min) was an unfavorable factor for the insertion into the ileocecum. Colonoscopy should be discontinued if freedom of the colonoscope body's insertion and rotation is completely lost, and the insertion time is prolonged over 30 min.
Chacaltana Mendoza, Alfonso; Rodríguez Ulloa, Carlos
2008-01-01
In search alternatives for colonoscopic preparation, we decided to compare the effectiveness, safety and tolerance of the use of 10% manitol with polyethyleneglycol. A prospective, randomized and simple blind study was performed. Eighty consecutive inpatients were prospectively randomized to receive bowel preparation for elective colonoscopy with either 1 liter of 10% manitol (M Group, n=40) or 4 liters of polyethyleneglycol (PEG Group, n=40). Criteria of evaluation were quality of preparation, pre and post preparation laboratory seric test (sodium, potassium, osmolarity) and the presence of undesirable side effects during the preparation. Both groups were comparable in age, sex and colonoscopic indications. There was no difference between both groups when evaluating the quality of preparation: good or excellent preparation of 87.5% (manitol Group) and 90% (PEG Group) (p=0.37). The frequency of adverse effects was minor in group manitol (30%) that in group PEG (42.5%), being the nausea the most frequent symptom in both groups. A slight increase in the levels of sodium, potassium and osmolarity serums was found in both groups, without statistical difference or clinical repercussion. The preparation for colon cleansing with 10% manitol is as effective and safe, but better tolerated and accepted than preparation with PEG. 10% manitol would be a good alternative for colonoscopic preparation, specially for diagnostic procedures.
Simulated training in colonoscopic stenting of colonic strictures: validation of a cadaver model.
Iordache, F; Bucobo, J C; Devlin, D; You, K; Bergamaschi, R
2015-07-01
There are currently no available simulation models for training in colonoscopic stent deployment. The aim of this study was to validate a cadaver model for simulation training in colonoscopy with stent deployment for colonic strictures. This was a prospective study enrolling surgeons at a single institution. Participants performed colonoscopic stenting on a cadaver model. Their performance was assessed by two independent observers. Measurements were performed for quantitative analysis (time to identify stenosis, time for deployment, accuracy) and a weighted score was devised for assessment. The Mann-Whitney U-test and Student's t-test were used for nonparametric and parametric data, respectively. Cohen's kappa coefficient was used for reliability. Twenty participants performed a colonoscopy with deployment of a self-expandable metallic stent in two cadavers (groups A and B) with 20 strictures overall. The median time was 206 s. The model was able to differentiate between experts and novices (P = 0. 013). The results showed a good consensus estimate of reliability, with kappa = 0.571 (P < 0.0001). The cadaver model described in this study has content, construct and concurrent validity for simulation training in colonoscopic deployment of self-expandable stents for colonic strictures. Further studies are needed to evaluate the predictive validity of this model in terms of skill transfer to clinical practice. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.
Colonic ulceration caused by administration of loxoprofen sodium.
Nakase, H; Itani, T; Mimura, J; Kawasaki, T; Komori, H; Hashimoto, K; Chiba, T
1999-03-01
A 54-year-old female with chronic headache was admitted to our hospital because of hematochezia. She had routinely taken loxoprofen sodium because of severe headache. Emergent colonoscopic examination revealed ulceration of the cecum. After administration of loxoprofen sodium was discontinued and administration of sulfasalazine was initiated, her intestinal bleeding subsided. Two months after discontinuation of loxoprofen sodium, the colonoscopic examination revealed scar formation at the site of cecal ulceration. In this case, it was conceivable that the administration of loxoprofen sodium might have induced colonic ulceration.
Patel, Ramnik V; Njere, Ike; Campbell, Alison; Daniel, Rejoo; Azaz, Amer; Fleet, Mahmud
2014-01-01
A case of acute sigmoid volvulus in a 14-year-old adolescent girl presenting with acute low large bowel obstruction with a background of chronic constipation has been presented. Abdominal radiograph and CT scan helped in diagnosis. She underwent emergency colonoscopic detorsion and decompression uneventfully. Lower gastrointestinal contrast study showed very redundant sigmoid colonic loop without any transition zone and she subsequently underwent elective sigmoid colectomy with good outcome. The sigmoid volvulus should be considered in the differential diagnosis of paediatric acute abdomen presenting with marked abdominal distention, absolute constipation and pain but without vomiting. Plain abdominal radiograph and the CT scan are helpful to confirm the diagnosis. Early colonoscopic detorsion and decompression allows direct visualisation of the vascular compromise, assessment of band width of the volvulus and can reduce complications and mortality. Associated Hirschsprung's disease should be suspected if clinical and radiological features are suggestive in which case a rectal biopsy before definitive surgery should be considered. PMID:25143313
Patel, Ramnik V; Njere, Ike; Campbell, Alison; Daniel, Rejoo; Azaz, Amer; Fleet, Mahmud
2014-08-20
A case of acute sigmoid volvulus in a 14-year-old adolescent girl presenting with acute low large bowel obstruction with a background of chronic constipation has been presented. Abdominal radiograph and CT scan helped in diagnosis. She underwent emergency colonoscopic detorsion and decompression uneventfully. Lower gastrointestinal contrast study showed very redundant sigmoid colonic loop without any transition zone and she subsequently underwent elective sigmoid colectomy with good outcome. The sigmoid volvulus should be considered in the differential diagnosis of paediatric acute abdomen presenting with marked abdominal distention, absolute constipation and pain but without vomiting. Plain abdominal radiograph and the CT scan are helpful to confirm the diagnosis. Early colonoscopic detorsion and decompression allows direct visualisation of the vascular compromise, assessment of band width of the volvulus and can reduce complications and mortality. Associated Hirschsprung's disease should be suspected if clinical and radiological features are suggestive in which case a rectal biopsy before definitive surgery should be considered. 2014 BMJ Publishing Group Ltd.
Lutgens, M W M D; Oldenburg, B; Siersema, P D; van Bodegraven, A A; Dijkstra, G; Hommes, D W; de Jong, D J; Stokkers, P C F; van der Woude, C J; Vleggaar, F P
2009-11-17
Colonoscopic surveillance provides the best practical means for preventing colorectal cancer (CRC) in inflammatory bowel disease (IBD) patients. Strong evidence for improved survival from surveillance programmes is sparse. The aim of this study was to compare tumour stage and survival of IBD patients with CRC who were a part of a surveillance programme with those who were not. A nationwide pathology database (PALGA (pathologisch anatomisch landelijk geautomatiseerd archief)) was consulted to identify IBD patients with CRC treated in all eight university hospitals in The Netherlands over a period of 15 years. Patients were assigned to the surveillance group when they had undergone one or more surveillance colonoscopies before a diagnosis of CRC. Patients who had not undergone surveillance served as controls. Tumour stage and survival were compared between the two groups. A total of 149 patients with IBD-associated CRC were identified. Twenty-three had had colonoscopic surveillance before CRC was discovered. The 5-year CRC-related survival rate of patients in the surveillance group was 100% compared with 74% in the non-surveillance group (P=0.042). In the surveillance group, only one patient died as a consequence of CRC compared with 29 patients in the control group (P=0.047). In addition, more early tumour stages were found in the surveillance group (P=0.004). These results provide evidence for improved survival from colonoscopic surveillance in IBD patients by detecting CRC at a more favourable tumour stage.
Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy
Kobayashi, Kiyonori; Mukae, Miyuki; Ogawa, Taishi; Yokoyama, Kaoru; Sada, Miwa; Koizumi, Wasaburo
2013-01-01
AIM: To evaluate the clinical usefulness of single-balloon endoscopy (SBE) in patients in whom a colonoscope was technically difficult to insert previously. METHODS: The study group comprised 15 patients (8 men and 7 women) who underwent SBE for colonoscopy (30 sessions). The number of SBE sessions was 1 in 7 patients, 2 in 5 patients, 3 in 1 patient, 4 in 1 patient, and 6 in 1 patient. In all patients, total colonoscopy was previously unsuccessful. The reasons for difficulty in scope passage were an elongated colon in 6 patients, severe intestinal adhesions after open surgery in 4, an elongated colon and severe intestinal adhesions in 2, a left inguinal hernia in 2, and multiple diverticulosis of the sigmoid colon in 1. Three endoscopists were responsible for SBE. The technique for inserting SBE in the colon was basically similar to that in the small intestine. The effectiveness of SBE was assessed on the basis of the success rate of total colonoscopy and the presence or absence of complications. We also evaluated the diagnostic and treatment outcomes of colonoscopic examinations with SBE. RESULTS: Total colonoscopy was successfully accomplished in all sessions. The mean insertion time to the cecum was 22.9 ± 8.9 min (range 9 to 40). Abnormalities were found during 21 sessions of SBE. The most common abnormality was colorectal polyps (20 sessions), followed by radiation colitis (3 sessions) and diverticular disease of the colon (3 sessions). Colorectal polyps were resected endoscopically in 15 sessions. A total of 42 polyps were resected endoscopically, using snare polypectomy in 32 lesions, hot biopsy in 7 lesions, and endoscopic mucosal resection in 3 lesions. Fifty-six colorectal polyps were newly diagnosed on colonoscopic examination with SBE. Histopathologically, these lesions included 2 intramucosal cancers, 42 tubular adenomas, and 2 tubulovillous adenomas. The mean examination time was 48.2 ± 20.0 min (range 25 to 90). Colonoscopic examination or endoscopic treatment with SBE was not associated with any serious complications. CONCLUSION: SBE is a useful and safe procedure in patients in whom a colonoscope is technically difficult to insert. PMID:23515370
Laparoscopic right-sided colonic resection with transluminal colonoscopic specimen extraction
Kayaalp, Cuneyt; Kutluturk, Koray; Yagci, Mehmet Ali; Ates, Mustafa
2015-01-01
AIM: To study the transcolonic extraction of the proximally resected colonic specimens by colonoscopic assistance at laparoscopic colonic surgery. METHODS: The diagnoses of our patients were Crohn’s disease, carcinoid of appendix and adenocarcinoma of cecum. We preferred laparoscopic total mesocolic resections. Colon and terminal ileum were divided with endoscopic staplers. A colonoscope was placed per anal and moved proximally in the colon till to reach the colonic closed end under the laparoscopic guidance. The stump of the colon was opened with laparoscopic scissors. A snare of colonoscope was released and the intraperitoneal complete free colonic specimen was grasped. Specimen was moved in to the colon with the help of the laparoscopic graspers and pulled gently through the large bowel and extracted through the anus. The open end of the colon was closed again and the ileal limb and the colon were anastomosed intracorporeally with a 60-mm laparoscopic stapler. The common enterotomy orifice was closed in two layers with a running intracorporeal suture. RESULTS: There were three patients with laparoscopic right-sided colonic resections and their specimens were intended to remove through the remnant colon by colonoscopy but the procedure failed in one patient (adenocarcinoma) due to a bulky mass and the specimen extraction was converted to transvaginal route. All the patients had prior abdominal surgeries and had related adhesions. The operating times were 210, 300 and 500 min. The lengths of the specimens were 13, 17 and 27 cm. In our cases, there were no superficial or deep surgical site infections or any other complications. The patients were discharged uneventfully within 4-5 d and they were asymptomatic after a mean 7.6 mo follow-up (ranged 4-12). As far as we know, there were only 12 cases reported yet on transcolonic extraction of the proximal colonic specimens by colonoscopic assistance after laparoscopic resections. With our cases, success rate of the overall experience in the literature was 80% (12/15) in selected cases. CONCLUSION: Transcolonic specimen extraction for right-sided colonic resection is feasible in selected patients. Both natural orifice surgery and intracorporeal anastomosis avoids mini-laparotomy for specimen extraction or anastomosis. PMID:26380054
Yoshikawa, Ichiro; Honda, Hidekazu; Nagata, Kaori; Kanda, Kikuo; Yamasaki, Takuji; Kume, Keiichiro; Tabaru, Akinari; Otsuki, Makoto
2002-12-01
Application of a new variable stiffness colonoscope (VSC) is expected to control loop formation and to lessen patient discomfort. The aim of this prospective study was to compare the efficacy of VSC with a conventional colonoscope (CC) in unsedated colonoscopy, based on the experience of examiners. Four-hundred sixty-seven patients were randomly assigned to undergo colonoscopy with either VSC or CC by an endoscopist, including experienced and less-experienced examiners. The percentages of completed procedure and time to cecal intubation were recorded. Patients were asked to rate pain on a 5-point pain score. The percentages of completed procedure with VSC and CC were 98% and 95%, respectively, by less-experienced hands, and 99% and 98%, respectively, by experienced hands. Time for cecal intubation with VSC and CC was 15.7 and 18.5 min, respectively, by less-experienced hands, and 9.8 and 10.6 min, respectively, by experienced hands. A significantly lower mean pain score was noted in VSC patients compared with CC patients, irrespective of experience of the examiner. The percent of patients rating the procedure as moderately or severely painful was significantly lower with VSC than with CC, both in less-experienced (19% vs 40%; p < 0.01) and experienced hands (15% vs 26%; p < 0.05). Our results indicated that VSC allows favorable examination compared with CC regarding completeness, time to cecal intubation, and comfort of patients undergoing unsedated colonoscopy, irrespective of the examiner's experience. These features suggest VSC as the preferred colonoscope for patients undergoing unsedated colonoscopy.
A new colonic lavage system to prepare the colon for colonoscopy: a retrospective study.
Ziv, Y; Scapa, E
2013-02-01
One of the most unpleasant and sometimes difficult elements of colonoscopic examination is the bowel preparation which is usually performed 6 or more hours prior to the examination ("early" preparation), causing many patients to refrain from undergoing this procedure. We present a novel technique for bowel preparation that begins approximately 30 min prior to the introduction of the colonoscope and eliminates the need for significant pre-procedure preparation. The medical records of all consecutive patients who underwent colonoscopy without "early" preparation (CWEP) from May 2009 through June 2010 were retrospectively reviewed. The procedure was performed using a novel cleansing device, the "ColonoScoPrep™", with which the colon is prepared about half an hour prior to insertion of the colonoscope. The only medication required is two to three bisacodyl tablets the night before. The quality of bowel preparation was graded as excellent, good, satisfactory, or poor, and patient satisfaction was assessed according to a prospective protocol. During this period, 125 patients underwent CWEP. Of these, 110 (89.4 %) patients had an excellent or good preparation, permitting complete colonoscopic examination unimpeded by fecal matter. In 11 patients, preparation was satisfactory, in 2 it was poor and in 2, colonoscopy was not completed due to unsatisfactory preparation. None of the patients suffered from abdominal pain or cramps during or after the CWEP and none had post-colonoscopy diarrhea. All patients were satisfied with the procedure. Despite the fact that the study is retrospective, CWEP appears safe and easy to perform. A prospective study comparing conventional bowel preparation and CWEP is now underway.
Incidence and management of colonoscopic perforations: 8 years’ experience
Tulchinsky, Hagit; Madhala-Givon, Osnat; Wasserberg, Nir; Lelcuk, Shlomo; Niv, Yaron
2006-01-01
AIM: To review the experience of a major medical teaching center with diagnostic and therapeutic colonoscopies and to assess the incidence and management of related colonic perforations. METHODS: All colonoscopies performed between January 1994 and December 2001 were studied. Data on patients, colonoscopic reports and procedure-related complications were collected from the departmental computerized database. The medical records of the patients with post procedural colonic perforation were reviewed. RESULTS: A total of 12 067 colonoscopies were performed during the 8 years of the study. Seven colonoscopic perforations (4 females, 3 males) were diagnosed (0.058%). Five occurred during diagnostic and two during therapeutic colonoscopy. Six were suspected during or immediately after colonoscopy. All except one had signs of diffuse tenderness and underwent immediate operation with primary repair done in 4 patients. No deaths were reported. CONCLUSION: Perforation rate during colonoscopy is low. Nevertheless, it is a serious complication and its early recognition and treatment are essential to optimize outcome. In patients with diffuse peritonitis early operative intervention makes primary repair a safe option. PMID:16830377
Colonoscopic Removal of an Intrauterine Device That Had Perforated the Rectosigmoid Colon
Huh, Jin Myeong; Kim, Ki Seok; Cho, Yong Seok; Lee, Jae Uk; Baek, Seong Deuk; Moon, Sin Kil
2018-01-01
The intrauterine device (IUD) is a widely used contraceptive method. One of the most serious and rare complications of using an IUD is colon perforation. We report a case of colonoscopic removal of an IUD that had perforated into the rectosigmoid colon in a 42-year-old woman who presented with no symptoms. Colonoscopy showed that the IUD had penetrated into rectosigmoid colon wall and that an arm of the IUD was embedded in the colon wall. We were able to remove the IUD easily by using colonoscopy. The endoscopic approach may be considered the first choice therapy for selected patients. PMID:29742863
Seo, Hyun Il; Lee, Dae Sung; Yoon, Eun Mi; Kwon, Min-Jung; Park, Hyosoon; Jung, Yoon Suk; Park, Jung Ho; Sohn, Chong Il
2016-01-01
Background/Aims To prevent the transmission of pathogens by endoscopes, following established reprocessing guidelines is critical. An ideal reprocessing step is simple, fast, and inexpensive. Here, we evaluated and compared the efficacy and safety of two disinfectants, a tertiary amine compound (TAC) and ortho-phthalaldehyde (OPA). Methods A total of 100 colonoscopes were randomly reprocessed using two same automated endoscope reprocessors, according to disinfectant. The exposure time was 10 minutes for 0.55% OPA (Cidex® OPA, Johnson & Johnson) and 5 minutes for 4% TAC (Sencron2®, Bab Gencel Pharma & Chemical Ind. Co.). Three culture samples were obtained from each colonoscope after reprocessing. Results A total of nine samples were positive among the 300 culture samples. The positive culture rate was not statistically different between the two groups (4% for OPA and 2% for TAC, P=0.501). There were no incidents related to safety during the study period. Conclusions TAC was non-inferior in terms of reprocessing efficacy to OPA and was safe to use. Therefore, TAC seems to be a good alternative disinfectant with a relatively short exposure time and is also less expensive than OPA. PMID:27175119
Swab culture monitoring of automated endoscope reprocessors after high-level disinfection
Lu, Lung-Sheng; Wu, Keng-Liang; Chiu, Yi-Chun; Lin, Ming-Tzung; Hu, Tsung-Hui; Chiu, King-Wah
2012-01-01
AIM: To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors (AERs) after high-level disinfection (HLD). METHODS: From February 2006 to January 2011, authors conducted randomized consecutive sampling each month for 7 AERs. Authors collected a total of 420 swab cultures, including 300 cultures from 5 gastroscope AERs, and 120 cultures from 2 colonoscope AERs. Swab cultures were obtained from the residual water from the AERs after a full reprocessing cycle. Samples were cultured to test for aerobic bacteria, anaerobic bacteria, and mycobacterium tuberculosis. RESULTS: The positive culture rate of the AERs was 2.0% (6/300) for gastroscope AERs and 0.8% (1/120) for colonoscope AERs. All the positive cultures, including 6 from gastroscope and 1 from colonoscope AERs, showed monofloral colonization. Of the gastroscope AER samples, 50% (3/6) were colonized by aerobic bacterial and 50% (3/6) by fungal contaminations. CONCLUSION: A full reprocessing cycle of an AER with HLD is adequate for disinfection of the machine. Swab culture is a useful method for monitoring AER decontamination after each reprocessing cycle. Fungal contamination of AERs after reprocessing should also be kept in mind. PMID:22529696
Coagulation syndrome: Delayed perforation after colorectal endoscopic treatments
Hirasawa, Kingo; Sato, Chiko; Makazu, Makomo; Kaneko, Hiroaki; Kobayashi, Ryosuke; Kokawa, Atsushi; Maeda, Shin
2015-01-01
Various procedure-related adverse events related to colonoscopic treatment have been reported. Previous studies on the complications of colonoscopic treatment have focused primarily on perforation or bleeding. Coagulation syndrome (CS), which is synonymous with transmural burn syndrome following endoscopic treatment, is another typical adverse event. CS is the result of electrocoagulation injury to the bowel wall that induces a transmural burn and localized peritonitis resulting in serosal inflammation. CS occurs after polypectomy, endoscopic mucosal resection (EMR), and even endoscopic submucosal dissection (ESD). The occurrence of CS after polypectomy or EMR varies according previous reports; most report an occurrence rate around 1%. However, artificial ulcers after ESD are largely theoretical, and CS following ESD was reported in about 9% of cases, which is higher than that for CS after polypectomy or EMR. Most cases of post-polypectomy syndrome (PPS) have an excellent prognosis, and they are managed conservatively with medical therapy. PPS rarely develops into delayed perforation. Delayed perforation is a severe adverse event that often requires emergency surgery. Since few studies have reported on CS and delayed perforation associated with CS, we focused on CS after colonoscopic treatments in this review. Clinicians should consider delayed perforation in CS patients. PMID:26380051
Effective and less invasive diagnostic strategy for gastrointestinal GVHD
Endo, Katsuya; Fujishima, Fumiyoshi; Kuroha, Masatake; Moroi, Rintaro; Onodera, Motoyuki; Naito, Takeo; Kanazawa, Yoshitake; Kimura, Tomoya; Shiga, Hisashi; Kakuta, Yoichi; Kinouchi, Yoshitaka; Shimosegawa, Tooru
2018-01-01
Background and study aims Rectosigmoidoscopy with biopsy has been regarded to be a useful procedure to diagnose gastrointestinal graft-versus-host disease (GVHD). However, little is known about the specific colonoscopic features of gastrointestinal GVHD. In this study, we focused on the 4 unique colonoscopic findings – orange peel appearance, spotty redness, small mucosal sloughing, and diffuse mucosal defect – which are possible specific findings of gastrointestinal GVHD. We aimed to estimate the usefulness of these four unique colonoscopic findings in the rectosigmoid portion to diagnose gastrointestinal GVHD. Patients and methods Seventy patients who were histologically diagnosed with gastrointestinal GVHD at our institute were retrospectively enrolled. Colonoscopic findings were reviewed, focusing on the four characteristic findings. The percentage of the positive cases for the characteristic findings was calculated. The final scoping portion and the number of cases showing any of the four characteristic findings in the rectosigmoid portion were also evaluated. The relationships between biopsy sites and the histological findings were also evaluated. Results Orange peel appearance was observed in 66 cases (94.3 %). Spotty redness was observed in 45 cases (64.3 %). Small mucosal sloughing was observed in 49 cases (70.0 %). Diffuse mucosal defect was observed in six cases (8.6 %). The number of cases that were concurrently positive for one, two, and three findings were 16 (20.8 %), 20 (26.0 %), and 34 (48.6 %), respectively. Fifty-eight cases (82.9 %) were investigated up to the rectosigmoid portion, and 12 (17.1 %) were investigated beyond the sigmoid colon. All of the cases showed at least 1 of the 4 characteristics in the rectosigmoid portion. The percentage of crypt apoptosis in the biopsy specimen from orange peel appearance, spotty redness, small mucosal sloughing, and diffuse mucosal defect were 87.5 %, 83.3 %, 87.2 %, and 88.9 %, respectively. Conclusion Orange peel appearance, spotty redness, small mucosal sloughing, and diffuse mucosal defect are the characteristic colonoscopic findings useful for diagnosis of gastrointestinal GVHD. These findings are frequently observed in the rectosigmoid portion. The histological detection rates for crypt cell apoptosis from these findings are high. Identifying the four characteristic findings on rectosigmoidoscopy and taking biopsies from these areas could be essential for the diagnostic strategy for gastrointestinal GVHD. PMID:29507868
Evaluation of a population-based approach to familial colorectal cancer.
Parfrey, P S; Dicks, E; Parfrey, O; McNicholas, P J; Noseworthy, H; Woods, M O; Negriin, C; Green, J
2017-05-01
As Newfoundland has the highest rate of familial colorectal cancer (CRC) in the world, we started a population-based clinic to provide colonoscopic and Lynch syndrome (LS) screening recommendations to families of CRC patients based on family risk. Of 1091 incident patients 51% provided a family history. Seventy-two percent of families were at low or intermediate-low risk of CRC and colonoscopic screening recommendations were provided by letter. Twenty-eight percent were at high and intermediate-high risk and were referred to the genetic counsellor, but only 30% (N = 48) were interviewed by study end. Colonoscopy was recommended more frequently than every 5 years in 35% of families. Lower family risk was associated with older age of proband but the frequency of screening colonoscopy recommendations varied across all age groups, driven by variability in family history. Twenty-four percent had a high MMR predict score for a Lynch syndrome mutation, and 23% fulfilled the Provincial Program criteria for LS screening. A population-based approach in the provision of colonoscopic screening recommendations to families at risk of CRC was limited by the relatively low response rate. A family history first approach to the identification of LS families was inefficient. © 2016 The Authors. Clinical Genetics published by John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Initial treatment of sigmoid volvulous by colonoscopy.
Starling, J R
1979-01-01
The initial management of acute, nonstrangulated sigmoid volvulous is to attempt proctosigmoidoscopic, rectal tube, or barium enema reduction and evacuation. If unsuccessful emergency surgery is necessary. The flexible colonoscope offers an additional therapeutic modality to effectuate preoperative reduction of the twisted sigmoid colon if attempts with conventional methods fail. Three cases of acute sigmoid volvulous are presented which illustrate for the first time successful reduction of acute sigmoid volvulous by colonoscopy after failure of the usual methods of treatment. Instead of emergency surgery all of these patients had elective resection with primary colocolostomy. Patients with acute sigmoid volvulous refractile to reduction by conventional modalities should have an attempt at flexible colonoscopic reduction. Images Fig. 1. Fig. 2. Fig. 3. Fig. 4. PMID:464675
Virtually assisted optical colonoscopy
NASA Astrophysics Data System (ADS)
Marino, Joseph; Qiu, Feng; Kaufman, Arie
2008-03-01
We present a set of tools used to enhance the optical colonoscopy procedure in a novel manner with the aim of improving both the accuracy and efficiency of this procedure. In order to better present the colon information to the gastroenterologist performing a conventional (optical) colonoscopy, we undistort the radial distortion of the fisheye view of the colonoscope. The radial distortion is modeled with a function that converts the fisheye view to the perspective view, where the shape and size of polyps can be more readily observed. The conversion, accelerated on the graphics processing unit and running in real-time, calculates the corresponding position in the fisheye view of each pixel on the perspective image. We also merge our previous work in computer-aided polyp detection for virtual colonoscopy into the optical colonoscopy environment. The physical colonoscope path in the optical colonoscopy is approximated with the hugging corner shortest path, which is correlated with the centerline in the virtual colonoscopy. With the estimated distance that the colonoscope has been inserted, we are able to provide the gastroenterologist with visual cues along the observation path as to the location of possible polyps found by the detection process. In order to present the information to the gastroenterologist in a non-intrusive manner, we have developed a friendly user interface to enhance the optical colonoscopy without being cumbersome, distracting, or resulting in a more lackadaisical inspection by the gastroenterologist.
A Survey of Colonoscopic Surveillance After Polypectomy
2014-01-01
Purpose Several guidelines have been proposed for surveillance colonoscopy after polypectomy. However, some discrepancies still exist between the guidelines and clinical practice. This study was conducted to identify Korean doctors' recommendations for the colonoscopic surveillance interval after polypectomy. Methods A survey of the attendees at the symposium of the 64th Annual Congress of the Korean Surgical Society was conducted. When the prepared clinical scenarios were given, attendees answered using a wireless radio-frequency audience response system. All responders' results were automatically counted immediately. Frequencies of different answers to each question were calculated, and our results were compared with those of previous surveys performed using the same questionnaire in the United States or Japan. Results The number of responder varied from 38 to 41. About 50% of valid responders selected 'follow-up in 3 years' for low-risk lesions, such as a 6-mm hyperplastic polyp, a 6-mm tubular adenoma, or two 6-mm tubular adenomas. Responders most-commonly selected 'follow-up in 1 year' for high-risk lesions, such as a 12-mm tubular adenoma with high grade dysplasia or a 12-mm tubulovillous adenoma. The majority of Korean doctors recommend postpolypectomy colonoscopic surveillance more frequently than American physicians did. Conclusion A discrepancy between the guidelines and clinical practice for the surveillance after polypectomy still exists in Korea. A surveillance program that can be easily and widely applied in clinical practice needs to be established. PMID:24851219
... in which a doctor uses a colonoscope or scope, to look inside your rectum and colon . Colonoscopy ... anus and into your rectum and colon. The scope inflates your large intestine with air for a ...
Allenspach, K; Vaden, S L; Harris, T S; Gröne, A; Doherr, M G; Griot-Wenk, M E; Bischoff, S C; Gaschen, F
2006-01-01
To evaluate the colonoscopic allergen provocation (COLAP) test as a new tool for the diagnosis of IgE-mediated food allergy. Oral food challenges as well as COLAP testing were performed in a colony of nine research dogs with proven immediate-type food allergic reactions. In addition, COLAP was performed in five healthy dogs. When compared with the oral challenge test, COLAP accurately determined 18 of 23 (73 per cent) positive oral challenge reactions (73 per cent) in dogs with food allergies and was negative in the healthy dogs. The accuracy of this new test may be higher than that for gastric sensitivity testing. Therefore, COLAP holds promise as a new test to confirm the diagnosis of suspect IgE-mediated food allergy in dogs.
Luo, Derek J Y; Hui, Aric Josun; Yan, Kenneth Kar-Lung; Ng, Siew Chien; Wong, Vincent Wai-Sun; Chan, Francis Ka-Leung; Cheong, Jessica P K; Lam, Phyllis P Y; Tse, Yee Kit; Lau, James Y W
2012-03-01
Complete colonoscopy examination cannot be performed in as many as 10% of cases. The new 9.2-mm ultrathin colonoscope (UTC) with an extra bending section may improve procedure tolerance and allow improvement in colonoscopy completion rate compared with a 12.9-mm standard colonoscope (SC). To compare the performance of the 9.2-mm UTC with that of the 12.9-mm SC. Prospective, randomized, controlled trial. Academic endoscopic unit. Subjects 18 years and older undergoing their first colonoscopy. Subjects were randomized to either the UTC or SC group. First and rescue successful cecal intubation rates, subject satisfaction scores, and sedation requirements were compared. A total of 1121 patients (56% women, mean age 53.6 years) were randomized to the UTC group (n = 551) or the SC group (n = 570). There was no statistically significant difference in the first successful cecal intubation rate between the UTC and SC groups (98.9% vs 97.4%, P = .057). The mean (standard deviation) dose of midazolam and pethidine used was significantly lower in the UTC group (2.65 [0.65] mg vs 2.82 [0.85] mg, P < .001 and 27.6 [7.4] mg vs 29.7 [9.6] mg, P < .001, respectively). The mean (standard deviation) patient satisfaction score was similar between groups (6.99 [2.89] vs 7.04 [3.06], P = .762). Of the 21 patients (1.9%) with an incomplete initial colonoscopy (6 in the UTC group and 15 in the SC group), all 6 in the UTC group had their procedure completed with an SC. Eleven of 15 patients in the SC group had their procedures completed with a UTC in the same session. Low failure rate may mask any difference between the 2 colonoscopes as a rescue instrument. The 9.2-mm UTC has performance characteristics similar to those of an SC in Chinese subjects undergoing their first colonoscopy performed by experienced and trainee endoscopists. ( NCT01142167.). Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Microscopic Colitis: Collagenous Colitis and Lymphocytic Colitis
... camera on one end, called a colonoscope or scope, to look inside the rectum and entire colon. ... through the rectum and into the colon. The scope inflates the large intestine with air to give ...
Hasan, Nazia; Gross, Seth A; Gralnek, Ian M; Pochapin, Mark; Kiesslich, Ralf; Halpern, Zamir
2014-12-01
Although standard colonoscopy is considered the optimal test to detect adenomas, it can have a significant adenoma miss rate. A major contributing factor to high miss rates is the inability to visualize adenomas behind haustral folds and at anatomic flexures. To compare the diagnostic yield of balloon-assisted colonoscopy versus standard colonoscopy in the detection of simulated polyps in a colon model. Prospective, cohort study. International gastroenterology meeting. A colon model composed of elastic material, which mimics the flexible structure of haustral folds, allowing for dynamic responses to balloon inflation, with embedded simulated colon polyps (n = 12 silicone "polyps"). Fifty gastroenterologists were recruited to identify simulated colon polyps in a colon model, first using standard colonoscopy immediately followed by balloon-assisted colonoscopy. Detection of simulated polyps. The median polyp detection rate for all simulated polyps was significantly higher with balloon-assisted as compared with standard colonoscopy (91.7% vs 45.8%, respectively; P < .0001). The significantly higher simulated polyp detection rate with balloon-assisted versus standard colonoscopy was notable both for non-obscured polyps (100.0% vs 75.0%; P < .0001) and obscured polyps (88.0% vs 25.0%; P < .0001). Non-randomized design, use of a colon model, and simulated colon polyps. As compared with standard colonoscopy, balloon-assisted colonoscopy detected significantly more obscured and non-obscured simulated polyps in a colon model. Clinical studies in human participants are being pursued to further evaluate this new colonoscopic technology. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Jang, Hui Won; Kim, Yoon Nam; Nam, Chung Mo; Lee, Hyun Jung; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee
2012-12-01
We examined whether the insertion time for colonoscopies performed after left-sided resection was different in patients with a colostomy from that in patients without a colostomy and identified factors that could impact colonoscopy performance. We included consecutive patients who underwent colonoscopy between July 2005 and March 2011 after left-sided colorectal resection for colorectal cancer. We classified surgical methods according to the presence or absence of a colostomy and evaluated colonoscope insertion time retrospectively. Furthermore, we analyzed factors that might affect insertion time. A total of 1,041 patients underwent colonoscopy after left-sided colorectal resection during the study period. The colonoscopy completion rate was 98.6 %, and the mean insertion time was 6.1 ± 4.6 min (median 4.7 min, range 0.3-35.8 min). A shorter resection length of colon, the presence of a colostomy, and a lower endoscopist case volume were found to be independent factors associated with prolonged insertion time in patients with left-sided colorectal resection. Among experienced colonoscopists, no colonoscopy-associated or clinical factors were found to affect insertion time. However, a shorter resection length of colon, the presence of a colostomy, and poor bowel preparation were associated with prolonged insertion time among inexperienced endoscopists. We identified three factors that affect colonoscope insertion time after left-sided colorectal resection, including the presence of a colostomy. Inexperienced endoscopists were much more affected by the presence of a colostomy after left-sided colorectal resection. These findings have implications for the practice and teaching of colonoscopy after left-sided colorectal resection.
Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study
NASA Astrophysics Data System (ADS)
Roth, Holger R.; Hampshire, Thomas E.; Helbren, Emma; Hu, Mingxing; Vega, Roser; Halligan, Steve; Hawkes, David J.
2014-03-01
Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.
Latest generation, wide-angle, high-definition colonoscopes increase adenoma detection rate.
Adler, Andreas; Aminalai, Alireza; Aschenbeck, Jens; Drossel, Rolf; Mayr, Michael; Scheel, Mathias; Schröder, Andreas; Yenerim, Timur; Wiedenmann, Bertram; Gauger, Ulrich; Roll, Stephanie; Rösch, Thomas
2012-02-01
Improvements to endoscopy imaging technologies might improve detection rates of colorectal cancer and patient outcomes. We compared the accuracy of the latest generation of endoscopes with older generation models in detection of colorectal adenomas. We compared data from 2 prospective screening colonoscopy studies (the Berlin Colonoscopy Project 6); each study lasted approximately 6 months and included the same 6 colonoscopists, who worked in private practice. Participants in group 1 (n = 1256) were all examined by using the latest generation of wide-angle, high-definition colonoscopes that were manufactured by the same company. Individuals in group 2 (n = 1400) were examined by endoscopists who used routine equipment (a mixture of endoscopes from different companies; none of those used to examine group 1). The adenoma detection rate was calculated on the basis of the number of all adenomas/number of all patients. There were no differences in patient parameters or withdrawal time between groups (8.0 vs 8.2 minutes). The adenoma detection rate was significantly higher in group 1 (0.33) than in group 2 (0.27; P = .01); a greater number of patients with least 1 adenoma were identified in group 1 (22.1%) than in group 2 (18.2%; P = .01). A higher percentage of high-grade dysplastic adenomas were detected in group 1 (1.19%) than in group 2 (0.57%), but this difference was not statistically significant (P = .06). The latest generation of wide-angle, high-definition colonoscopes improves rates of adenoma detection by 22%, compared with mixed, older technology endoscopes used in routine private practice. These findings might affect definitions of quality control parameters for colonoscopy screening for colorectal cancer. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sargent, Dusty; Chen, Chao-I.; Wang, Yuan-Fang
2010-02-01
The paper reports a fully-automated, cross-modality sensor data registration scheme between video and magnetic tracker data. This registration scheme is intended for use in computerized imaging systems to model the appearance, structure, and dimension of human anatomy in three dimensions (3D) from endoscopic videos, particularly colonoscopic videos, for cancer research and clinical practices. The proposed cross-modality calibration procedure operates this way: Before a colonoscopic procedure, the surgeon inserts a magnetic tracker into the working channel of the endoscope or otherwise fixes the tracker's position on the scope. The surgeon then maneuvers the scope-tracker assembly to view a checkerboard calibration pattern from a few different viewpoints for a few seconds. The calibration procedure is then completed, and the relative pose (translation and rotation) between the reference frames of the magnetic tracker and the scope is determined. During the colonoscopic procedure, the readings from the magnetic tracker are used to automatically deduce the pose (both position and orientation) of the scope's reference frame over time, without complicated image analysis. Knowing the scope movement over time then allows us to infer the 3D appearance and structure of the organs and tissues in the scene. While there are other well-established mechanisms for inferring the movement of the camera (scope) from images, they are often sensitive to mistakes in image analysis, error accumulation, and structure deformation. The proposed method using a magnetic tracker to establish the camera motion parameters thus provides a robust and efficient alternative for 3D model construction. Furthermore, the calibration procedure does not require special training nor use expensive calibration equipment (except for a camera calibration pattern-a checkerboard pattern-that can be printed on any laser or inkjet printer).
Alfa, Michelle J; Olson, Nancy
2016-05-04
The objective of this study was to validate the relative light unit (RLU) cut-off of adequate cleaning of flexible colonoscopes for an ATP (adenosine tri-phosphate) test kit that used a sponge channel collection method. This was a simulated-use study. The instrument channel segment of a flexible colonoscope was soiled with ATS (artificial test soil) containing approximately 8 Log10 Enterococcus faecalis and Pseudomonas aeruginosa/mL. Full cleaning, partial cleaning and no cleaning were evaluated for ATP, protein and bacterial residuals. Channel samples were collected using a sponge device to assess residual RLUs. Parallel colonoscopes inoculated and cleaned in the same manner were sampled using the flush method to quantitatively assess protein and bacterial residuals. The protein and viable count benchmarks for adequate cleaning were <6.4 ug/cm(2) and <4 Log10 cfu/cm(2). The negative controls for the instrument channel, over the course of the study remained low with on average 14 RLUs, 0.04 ug/cm(2) protein and 0.025 Log10 cfu/cm(2). Partial cleaning resulted in an average of 6601 RLUs, 3.99 ug/cm(2), 5.25 Log10 cfu/cm(2) E. faecalis and 4.48 Log10 cfu/cm(2) P. aeruginosa. After full cleaning, the average RLU was 29 (range 7-71 RLUs) and the average protein, E. faecalis and P. aeruginosa residuals were 0.23 ug/cm(2), 0.79 and 1.61 Log10 cfu/cm(2), respectively. The validated cut-off for acceptable manual cleaning was set at ≤100 RLUs for the sponge collected channel ATP test kit.
Operative colonoscopic endoscopy.
Van Gossum, A; Bourgeois, F; Gay, F; Lievens, P; Adler, M; Cremer, M
1992-01-01
There are several conditions where operative colonoscopy is useful. Acute colonic pseudo-obstruction or Ogilvie's syndrome is characterized by a acute distension of the colon. Although medical management may be sufficient in many cases, endoscopic decompression must be performed when colonic distension is greater than 12 cm. Insertion of decompression tube to avoid rapid recurrence seems to be adequate. In case of massive lower intestinal hemorrhage, colonoscopy seems to be more accurate than mesenteric angiography. Such endoscopic examination requires an experienced endoscopist. Colonoscopic polypectomy has become the standard method for removal of colonic polyps. Factors influencing the rate of complications have been studied. While the number of complications was very low, we have observed that all the major hemorrhages were immediate when the blended current was used, but delayed when the pure coagulation current was applied. Endoscopic laser photocavitation is a valuable palliative method treating rectal adenocarcinoma in well selected patients. Indeed, if the patients survive sufficiently long after initial therapy, it becomes increasingly difficult to achieve persistent palliation with laser therapy.
Wen, Tingxi; Medveczky, David; Wu, Jackie; Wu, Jianhuang
2018-01-25
Colonoscopy plays an important role in the clinical screening and management of colorectal cancer. The traditional 'see one, do one, teach one' training style for such invasive procedure is resource intensive and ineffective. Given that colonoscopy is difficult, and time-consuming to master, the use of virtual reality simulators to train gastroenterologists in colonoscopy operations offers a promising alternative. In this paper, a realistic and real-time interactive simulator for training colonoscopy procedure is presented, which can even include polypectomy simulation. Our approach models the colonoscopy as thick flexible elastic rods with different resolutions which are dynamically adaptive to the curvature of the colon. More material characteristics of this deformable material are integrated into our discrete model to realistically simulate the behavior of the colonoscope. We present a simulator for training colonoscopy procedure. In addition, we propose a set of key aspects of our simulator that give fast, high fidelity feedback to trainees. We also conducted an initial validation of this colonoscopic simulator to determine its clinical utility and efficacy.
Khuroo, Mehnaaz S
2014-01-01
Hodgkin's lymphoma complicating chronic ulcerative colitis is extremely rare. We report a case of extranodal Hodgkin's lymphoma involving rectosigmoid in a patient of chronic ulcerative colitis on long-term azathioprine. A 67-year-old man presented with extensive ulcerative colitis, on follow-up since September 2005. He received long-term steroids, mesalamine and azathioprine. Serial surveillance colonoscopic examinations and colonic biopsies were performed. Surveillance colonoscopy performed 8 years after the onset of disease showed multiple deep ulcers and nodular masses involving the rectum and sigmoid colon. Histological examination of rectosigmoid biopsies showed classic Hodgkin's disease. Azathioprine was withdrawn. He received mechlorethamine, vincristine, procarbazine and prednisone (MOPP) chemotherapy protocol and was planned for total colectomy in follow-up. We believe patients with ulcerative colitis on long-term azathioprine should be on vigil for development of lymphomas by protocol surveillance colonoscopic examinations and biopsies. The risk of lymphoma in such patients is small and outweighs the benefits of long-term azathioprine therapy. PMID:24849639
Niccum, David E.; Billings, Joanne L.; Dunitz, Jordan M.; Khoruts, Alexander
2018-01-01
Background Colorectal cancer is an emerging problem in cystic fibrosis (CF). The goal of this study was to evaluate adenoma detection by systematic colonoscopic screening and surveillance. Methods We analyzed prospectively collected results of colonoscopies initiated at age 40 years from 88 CF patients at a single Cystic Fibrosis Center. We also reviewed results of diagnostic colonoscopies from 27 patients aged 30–39 years performed during the same time period at the Center. Results The incidence of polyp detection increased markedly after age 40 in CF patients. Greater than 50% were found to have adenomatous polyps; approximately 25% had advanced adenomas as defined by size and/or histopathology; 3% were found to have colon cancer. Multivariate analysis demonstrated specific risk factors for adenoma formation and progression. Conclusions Early screening and more frequent surveillance should be considered in patients with CF due to early incidence and progression of adenomas in this patient population. PMID:26851188
Mills, Christopher D; McCamley, Chere; Swan, Michael P
2018-03-07
To determine the effect of carbon dioxide insufflation on the most important outcome measure of colonoscopic quality: adenoma detection rate (ADR). Bowel cancer is the second most common cause of cancer deaths in males and females in Australia. Carbon dioxide has in recent times become the insufflation methodology of choice for screening colonoscopy for bowel cancer, as this has been shown to have significant advantages when compared with traditional air insufflation. Endoscopies performed over a period of 9 months immediately before and after the implementation of carbon dioxide insufflation at endoscopy centers were eligible for inclusion. The difference in ADR between the carbon dioxide and air insufflation methods was statistically significant, with an increased ADR in the carbon dioxide group. The superiority of carbon dioxide insufflation was sustained with a logistic regression model, which showed ADR was significantly impacted by insufflation method. Carbon dioxide insufflation is known to reduce abdominal pain, postprocedural duration of abdominal pain, abdominal distension, and analgesic requirements. This study represents for the first time the beneficial effect of carbon dioxide insufflation upon the key quality colonoscopy indicator of ADR.
Accuracy of colonoscopy in localizing colonic cancer.
Stanciu, C; Trifan, Anca; Khder, Saad Alla
2007-01-01
It is important to establish the precise localization of colonic cancer preoperatively; while colonoscopy is regarded as the diagnostic gold standard for colorectal cancer, its ability to localize the tumor is less reliable. To define the accuracy of colonoscopy in identifying the location of colonic cancer. All of the patients who had a colorectal cancer diagnosed by colonoscopy at the Institute of Gastroenterology and Hepatology, Iaşi and subsequently received a surgical intervention at three teaching hospitals in Iaşi, between January 2001 and December 2005, were included in this study. Endoscopic records and operative notes were carefully reviewed, and tumor localization was recorded. There were 161 patients (89 men, 72 women, aged 61.3 +/- 12.8 years) who underwent conventional surgery for colon cancer detected by colonoscopy during the study period. Twenty-two patients (13.66%) had erroneous colonoscopic localization of the tumors. The overall accuracy of preoperative colonoscopic localization was 87.58%. Colonoscopy is an accurate, reliable method for locating colon cancer, although additional techniques (i.e., endoscopic tattooing) should be performed at least for small lesions.
Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation
Tongprasert, Sasinee; Sobhonslidsuk, Abhasnee; Rattanasiri, Sasivimol
2009-01-01
AIM: To evaluate the effectiveness of simethicone in enhancing visibility and efficacy during colonoscopy. METHODS: A prospective, double-blind, randomized, placebo-controlled study was conducted. One hundred and twenty-four patients were allocated to receive 2 doses of sodium phosphate plus 240 mg of tablet simethicone or placebo as bowel preparation. Visibility was blindly assessed for the amount of air bubbles and adequacy of colon preparation. Total colonoscopic time, side effects of the medication, endoscopist and patient satisfaction were also compared. RESULTS: Sodium phosphate plus simethicone, compared to sodium phosphate plus placebo, improved visibility by diminishing air bubbles (100.00% vs 42.37%, P < 0.0001) but simethicone failed to demonstrate improvement in adequacy of colon preparation (90.16% vs 81.36%, P = 0.17). Endoscopist and patient satisfaction were increased significantly in the simethicone group. However, there was no difference in the total duration of colonoscopy and side effects of the medication. CONCLUSION: The addition of simethicone is of benefit for colonoscopic bowel preparation by diminishing air bubbles, which results in enhanced visibility. Endoscopist and patient satisfaction is also increased. PMID:19554657
Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation.
Tongprasert, Sasinee; Sobhonslidsuk, Abhasnee; Rattanasiri, Sasivimol
2009-06-28
To evaluate the effectiveness of simethicone in enhancing visibility and efficacy during colonoscopy. A prospective, double-blind, randomized, placebo-controlled study was conducted. One hundred and twenty-four patients were allocated to receive 2 doses of sodium phosphate plus 240 mg of tablet simethicone or placebo as bowel preparation. Visibility was blindly assessed for the amount of air bubbles and adequacy of colon preparation. Total colonoscopic time, side effects of the medication, endoscopist and patient satisfaction were also compared. Sodium phosphate plus simethicone, compared to sodium phosphate plus placebo, improved visibility by diminishing air bubbles (100.00% vs 42.37%, P < 0.0001) but simethicone failed to demonstrate improvement in adequacy of colon preparation (90.16% vs 81.36%, P = 0.17). Endoscopist and patient satisfaction were increased significantly in the simethicone group. However, there was no difference in the total duration of colonoscopy and side effects of the medication. The addition of simethicone is of benefit for colonoscopic bowel preparation by diminishing air bubbles, which results in enhanced visibility. Endoscopist and patient satisfaction is also increased.
The evaluation of risk-benefit ratio for gut tissue sampling in HIV cure research.
Mehraj, Vikram; Ghali, Peter; Ramendra, Rayoun; Costiniuk, Cecilia; Lebouché, Bertrand; Ponte, Rosalie; Reinhard, Robert; Sousa, Jose; Chomont, Nicolas; Cohen, Eric A; Ancuta, Petronela; Routy, Jean-Pierre
2017-10-01
Antiretroviral therapy (ART) does not cure HIV infection due to the persistence of HIV reservoirs in long-lived memory CD4 T cells present in the blood, lymph nodes, intestinal tract, and other tissues. Interest grows in obtaining gut-tissue samples for HIV persistence studies, which poses an ethical challenge to provide study volunteers with adequate information on risks and benefits. Herein we assess the risks and benefits of undergoing gut biopsy procedures for HIV pathogenesis and reservoir studies. A group discussion was organised with physicians and community representatives on performing either a flexible sigmoidoscopy or a colonoscopy. Consensus was reached on conducting colonoscopy in persons ≥50 years. Thirty HIV-infected, ART-treated and nine uninfected participants were recruited. Colonoscopy was performed to collect 30 gut mucosal biopsies. When present, polyps were removed and abnormal mucosal findings were biopsied for pathological analysis. Participants were interviewed on potential discomfort following colonoscopic examination. The HIV-infected and uninfected groups were comparable in terms of age and gender with more men who have sex with men (MSM) in the former group. Abnormal colonoscopic findings were observed in 43.6% of all the participants and did not differ by HIV status. In total, 24 polyps were removed with a higher mean number of polyps removed in HIV-infected versus uninfected participants (1.7 vs 1.0, P =0.013). The number of polyps marginally correlated with inverted CD4:CD8 ratio. Based on our findings, colonoscopic examination was safe to use for gut biopsy procedures where almost half of the participants had polyps removed. Participation in the study provided colon cancer screening as an ancillary benefit that participants could have received in standard medical care, thus mitigating burdens of invasive procedures. Dialogue between community representatives and clinical researchers can increase participation and advance HIV cure research.
2012-01-01
Background The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. Methods We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. Results The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Conclusions Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not. PMID:22943739
Chiu, King-Wah; Tsai, Ming-Chao; Wu, Keng-Liang; Chiu, Yi-Chun; Lin, Ming-Tzung; Hu, Tsung-Hui
2012-09-03
The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.
Prospective analysis of delayed colorectal post-polypectomy bleeding.
Park, Soo-Kyung; Seo, Jeong Yeon; Lee, Min-Gu; Yang, Hyo-Joon; Jung, Yoon Suk; Choi, Kyu Yong; Kim, Hungdai; Kim, Hyung Ook; Jung, Kyung Uk; Chun, Ho-Kyung; Park, Dong Il
2018-01-17
Although post-polypectomy bleeding is the most frequent complication after colonoscopic polypectomy, only few studies have investigated the incidence of bleeding prospectively. The aim of this study was to investigate the incidence of delayed post-polypectomy bleeding and its associated risk factors prospectively. Patients who underwent colonoscopic polypectomy at Kangbuk Samsung Hospital from January 2013 to December 2014 were prospectively enrolled in this study. Trained nurses contacted patients via telephone 7 and 30 days after polypectomy and completed a standardized questionnaire regarding the development of bleeding. Delayed post-polypectomy bleeding was categorized as minor or major and early or late bleeding. Major delayed bleeding was defined as a > 2-g/dL drop in the hemoglobin level, requiring hospitalization for control of bleeding or blood transfusion; late delayed bleeding was defined as bleeding occurring later than 24 h after polypectomy. A total of 8175 colonoscopic polypectomies were performed in 3887 patients. Overall, 133 (3.4%) patients developed delayed post-polypectomy bleeding. Among them, 90 (2.3%) and 43 (1.1%) patients developed minor and major delayed bleeding, respectively, and 39 (1.0%) patients developed late delayed bleeding. In the polyp-based multivariate analysis, young age (< 50 years; odds ratio [OR] 2.10; 95% confidence interval [CI] 1.18-3.68), aspirin use (OR 2.78; 95% CI 1.23-6.31), and polyp size of > 10 mm (OR 2.45; 95% CI 1.38-4.36) were significant risk factors for major delayed bleeding, while young age (< 50 years; OR 2.6; 95% CI 1.35-5.12) and immediate bleeding (OR 3.3; 95% CI 1.49-7.30) were significant risk factors for late delayed bleeding. Young age, aspirin use, polyp size, and immediate bleeding were found to be independent risk factors for delayed post-polypectomy bleeding.
Existing guidelines recommend colorectal cancer (CRC) screening for all patients over age 50. However, CRC remains the second leading cause of cancer death among Americans largely because colonoscopic screening of all the >100 million Americans over age 50 is unfeasible for both patient-related (non-compliance) and societal (inadequate endoscopic capacity and funding) reasons.
Appropriate treatment of acute sigmoid volvulus in the emergency setting
Lou, Zheng; Yu, En-Da; Zhang, Wei; Meng, Rong-Gui; Hao, Li-Qiang; Fu, Chuan-Gang
2013-01-01
AIM: To investigate an appropriate strategy for the treatment of patients with acute sigmoid volvulus in the emergency setting. METHODS: A retrospective review of 28 patients with acute sigmoid volvulus treated in the Department of Colorectal Surgery, Changhai Hospital, Shanghai from January 2001 to July 2012 was performed. Following the diagnosis of acute sigmoid volvulus, an initial colonoscopic approach was adopted if there was no evidence of diffuse peritonitis. RESULTS: Of the 28 patients with acute sigmoid volvulus, 19 (67.9%) were male and 9 (32.1%) were female. Their mean age was 63.1 ± 22.9 years (range, 21-93 years). Six (21.4%) patients had a history of abdominal surgery, and 17 (60.7%) patients had a history of constipation. Abdominal radiography or computed tomography was performed in all patients. Colonoscopic detorsion was performed in all 28 patients with a success rate of 92.8% (26/28). Emergency surgery was required in the other two patients. Of the 26 successfully treated patients, seven (26.9%) had recurrent volvulus. CONCLUSION: Colonoscopy is the primary emergency treatment of choice in uncomplicated acute sigmoid volvulus. Emergency surgery is only for patients in whom nonoperative treatment is unsuccessful, or in those with peritonitis. PMID:23946604
Computer-aided diagnosis (CAD) for colonoscopy
NASA Astrophysics Data System (ADS)
Gu, Jia; Poirson, Allen
2007-03-01
Colorectal cancer is the second leading cause of cancer deaths, and ranks third for new cancer cases and cancer mortality for both men and women. However, its death rate can be dramatically reduced by appropriate treatment when early detection is available. The purpose of colonoscopy is to identify and assess the severity of lesions, which may be flat or protruding. Due to the subjective nature of the examination, colonoscopic proficiency is highly variable and dependent upon the colonoscopist's knowledge and experience. An automated image processing system providing an objective, rapid, and inexpensive analysis of video from a standard colonoscope could provide a valuable tool for screening and diagnosis. In this paper, we present the design, functionality and preliminary results of its Computer-Aided-Diagnosis (CAD) system for colonoscopy - ColonoCAD TM. ColonoCAD is a complex multi-sensor, multi-data and multi-algorithm image processing system, incorporating data management and visualization, video quality assessment and enhancement, calibration, multiple view based reconstruction, feature extraction and classification. As this is a new field in medical image processing, our hope is that this paper will provide the framework to encourage and facilitate collaboration and discussion between industry, academia, and medical practitioners.
Gastroenterology service in a teaching hospital in rural New Zealand, 1991-2003
Schultz, Michael; Davidson, Andrew; Donald, Sarah; Targonska, Bogna; Turnbull, Angus; Weggery, Susan; Livingstone, Vicki; Dockerty, John D
2009-01-01
AIM: To retrospectively collect inpatient and outpatient data and to assess the use of endoscopic procedures during the years 1991, 1997 and 2003 to analyse for trends. METHODS: This retrospective survey was conducted in a University-associated Gastroenterology Unit offering secondary and tertiary health care services for a population of approximately 182 000 people in Southern New Zealand. Data collected included patient contacts (in- and outpatients), gastroscopic and colonoscopic investigations. RESULTS: We observed a significant increase in the absolute numbers of patient contacts over the years (1991: 2308 vs 1997: 2022 vs 2003: 2783, P < 0.0001) with inflammatory bowel disease, other diseases of the colon, anus and rectum and iron studies related disorders decreasing significantly but liver disease and constipation increasing linearly over time. The use of endoscopy services remained relatively stable but colonoscopic investigations for a positive family history of colorectal cancer increased significantly while more gastroscopies were performed for unexplained anaemia. CONCLUSION: The whole spectrum of gastroenterology contacts was studied. A substantial proportion of colonoscopies and outpatient consultations were undertaken to screen for colorectal cancer. This proportion is likely to grow further. Our findings have implications for the recruitment and training of the next generation of gastroenterologists. PMID:19195060
Ashktorab, Hassan; Etaati, Firoozeh; Rezaeean, Farahnaz; Nouraie, Mehdi; Paydar, Mansour; Namin, Hassan Hassanzadeh; Sanderson, Andrew; Begum, Rehana; Alkhalloufi, Kawtar; Brim, Hassan; Laiyemo, Adeyinka O
2016-07-28
To study the accuracy of using high definition (HD) scope with narrow band imaging (NBI) vs standard white light colonoscope without NBI (ST), to predict the histology of the colon polyps, particularly those < 1 cm. A total of 147 African Americans patients who were referred to Howard University Hospital for screening or, diagnostic or follow up colonoscopy, during a 12-mo period in 2012 were prospectively recruited. Some patients had multiple polyps and total number of polyps was 179. Their colonoscopies were performed by 3 experienced endoscopists who determined the size and stated whether the polyps being removed were hyperplastic or adenomatous polyps using standard colonoscopes or high definition colonoscopes with NBI. The histopathologic diagnosis was reported by pathologists as part of routine care. Of participants in the study, 55 (37%) were male and median (interquartile range) of age was 56 (19-80). Demographic, clinical characteristics, past medical history of patients, and the data obtained by two instruments were not significantly different and two methods detected similar number of polyps. In ST scope 89% of polyps were < 1 cm vs 87% in HD scope (P = 0.7). The ST scope had a positive predictive value (PPV) and positive likelihood ratio (PLR) of 86% and 4.0 for adenoma compared to 74% and 2.6 for HD scope. There was a trend of higher sensitivity for HD scope (68%) compare to ST scope (53%) with almost the same specificity. The ST scope had a PPV and PLR of 38% and 1.8 for hyperplastic polyp (HPP) compared to 42% and 2.2 for HD scope. The sensitivity and specificity of two instruments for HPP diagnosis were similar. Our results indicated that HD scope was more sensitive in diagnosis of adenoma than ST scope. Clinical diagnosis of HPP with either scope is less accurate compared to adenoma. Colonoscopy diagnosis is not yet fully matched with pathologic diagnosis of colon polyp. However with the advancement of both imaging and training, it may be possible to increase the sensitivity and specificity of the scopes and hence save money for eliminating time and the cost of Immunohistochemistry/pathology.
Boenicke, L; Maier, M; Merger, M; Bauer, M; Buchberger, C; Schmidt, C; Thiede, A; Gassel, H-J
2006-04-01
Abdominal gas gangrene caused by clostridia species is rare and usually associated with organ perforation, immune suppression, or advanced malignoma. A 61-year-old man was admitted with severe back pain 1 day after uncomplicated colonoscopic polypectomy. With the exception of preexisting minor depression, the patient had been previously in excellent health. The computed tomography scan showed retroperitoneal emphysema in the left psoas muscle. During exploratory laparotomy, a spreading retroperitoneal phlegmon with pneumoretroperitoneum and a secondary peritonitis were found. A macroscopic perforation of the gut, particularly at the polypectomy sites was excluded. After the operation, the patient evolved in a septic shock condition and had pulmonary failure. Before hyperbaric oxygen therapy could be employed, the patient died. The autopsy showed a massive gas gangrene of the retroperitoneum caused by Clostridium perfringens, but no macroscopic bowel perforation was detected. This is the first report of a case of gas gangrene after uncomplicated polypectomy without macroscopic perforation in an otherwise healthy individual. A microperforation due to mucosal defect after polypectomy was most likely the entry point for the bacteria. We conclude that clostridial myonecrosis should be considered in unclear abdominal infections, even if the patient's history is not typical as in the present case.
Successful Endoscopic Submucosal Dissection of a Large Terminal Ileal Lipoma
Noda, Hisatsugu; Ogasawara, Naotaka; Tamura, Yasuhiro; Kondo, Yoshihiro; Izawa, Shinya; Ebi, Masahide; Funaki, Yasushi; Sasaki, Makoto; Kasugai, Kunio
2016-01-01
A 78-year-old woman who had recurrent right lower abdominal pain for about 1 year underwent computed tomography (CT) because of a follow-up observation 1 year after right breast cancer surgery. CT revealed a tumor in the colon. The patient was referred to our hospital for detailed examinations. An abdominal CT showed a low-density tumor of approximately 30 mm in the ascending colon, and the CT density inside the tumor was same as that of fatty tissues. A subsequent colonoscopy showed a submucosal tumor (SMT) in the proximal ascending colon developing from the terminal ileum. A colonoscopic ultrasonography revealed that the SMT was a high-echoic mass mainly localized in the submucosal layer. Based on the findings from CT, colonoscopy, and colonoscopic ultrasonography, the SMT was diagnosed as a pedunculated lipoma originating from the terminal ileum and treated with endoscopic submucosal dissection (ESD) because of recurrent abdominal pain. The 40-mm tumor was resected en bloc without complications. ESD may be more appropriate than polypectomy and surgery for removal of small intestinal tumors, because ESD allows direct visualization of the cutting line and exactly dissects the submucosal layers without damaging the muscular layers. ESD is a potentially useful treatment to remove intestinal lipomas. PMID:27843426
Clinical correlates of trichuriasis diagnosed at colonoscopy.
Jha, Ashish Kumar; Goenka, Mahesh Kumar; Suchismita, Arya
2017-09-01
Diagnosis of Trichuris trichiura infestations is usually based on identification of barrel-shaped ova in stool, but is frequently missed on stool microscopy. We describe the clinical profile of patients in whom Trichuris infection was incidentally diagnosed at colonoscopy. In a cross-sectional study, patients with colonoscopic diagnosis of trichuriasis were enrolled from the endoscopy unit in a tertiary care center. Blood and stool samples were collected from all those who were willing to participate and provide samples. Sixty-two patients participated, with mean (SD) age of 50.5 (13.6) years and male to female ratio of 40:22. Abdominal pain (61.2%) and/or altered bowel habits (32.2%) were the most common indication for colonoscopy. Most (66.6%) of the Trichuris were located in the cecum and ascending colon. Majority of the patients had live worms, either motile or adhering to the colonic mucosa. The number of worms was single or a few (<15) in 74.2% of patients. Out of 62 patients, 16 (25.8%) had relatively heavy load of parasites. Most patients had normal colonoscopic findings (80.6%). Periappendicular and/or cecal ulcerations/erosions were the most common (16.1%) abnormalities noted. Stool examination showed parasite ova only in four (6.4%) patients. In conclusion, colonoscopy was better than stool microscopy for the diagnosis of trichuriasis in our study.
1988-04-01
on the fifth hospital day h-is found in the Leum. Gram and Warthin -Starry stains showed stone-filled gallbladder was removed; the intraoperative exami...colonoscopic findings were considered to be all antibiotic treatments tested. Erythromycin therapy was con- most consistent with Crohn ileitis, prednisone...erally, he had 6 to 10 watery stools per day for 3 weeks each manIA). month. Sigmoidoscopic findings were consistent with Crohn ifornia). disease
Ashktorab, Hassan; Etaati, Firoozeh; Rezaeean, Farahnaz; Nouraie, Mehdi; Paydar, Mansour; Namin, Hassan Hassanzadeh; Sanderson, Andrew; Begum, Rehana; Alkhalloufi, Kawtar; Brim, Hassan; Laiyemo, Adeyinka O
2016-01-01
AIM: To study the accuracy of using high definition (HD) scope with narrow band imaging (NBI) vs standard white light colonoscope without NBI (ST), to predict the histology of the colon polyps, particularly those < 1 cm. METHODS: A total of 147 African Americans patients who were referred to Howard University Hospital for screening or, diagnostic or follow up colonoscopy, during a 12-mo period in 2012 were prospectively recruited. Some patients had multiple polyps and total number of polyps was 179. Their colonoscopies were performed by 3 experienced endoscopists who determined the size and stated whether the polyps being removed were hyperplastic or adenomatous polyps using standard colonoscopes or high definition colonoscopes with NBI. The histopathologic diagnosis was reported by pathologists as part of routine care. RESULTS: Of participants in the study, 55 (37%) were male and median (interquartile range) of age was 56 (19-80). Demographic, clinical characteristics, past medical history of patients, and the data obtained by two instruments were not significantly different and two methods detected similar number of polyps. In ST scope 89% of polyps were < 1 cm vs 87% in HD scope (P = 0.7). The ST scope had a positive predictive value (PPV) and positive likelihood ratio (PLR) of 86% and 4.0 for adenoma compared to 74% and 2.6 for HD scope. There was a trend of higher sensitivity for HD scope (68%) compare to ST scope (53%) with almost the same specificity. The ST scope had a PPV and PLR of 38% and 1.8 for hyperplastic polyp (HPP) compared to 42% and 2.2 for HD scope. The sensitivity and specificity of two instruments for HPP diagnosis were similar. CONCLUSION: Our results indicated that HD scope was more sensitive in diagnosis of adenoma than ST scope. Clinical diagnosis of HPP with either scope is less accurate compared to adenoma. Colonoscopy diagnosis is not yet fully matched with pathologic diagnosis of colon polyp. However with the advancement of both imaging and training, it may be possible to increase the sensitivity and specificity of the scopes and hence save money for eliminating time and the cost of Immunohistochemistry/pathology. PMID:27605888
Alfa, Michelle J; Fatima, Iram; Olson, Nancy
2013-03-01
The study objective was to verify that the adenosine triphosphate (ATP) benchmark of <200 relative light units (RLUs) was achievable in a busy endoscopy clinic that followed the manufacturer's manual cleaning instructions. All channels from patient-used colonoscopes (20) and duodenoscopes (20) in a tertiary care hospital endoscopy clinic were sampled after manual cleaning and tested for residual ATP. The ATP test benchmark for adequate manual cleaning was set at <200 RLUs. The benchmark for protein was <6.4 μg/cm(2), and, for bioburden, it was <4-log10 colony-forming units/cm(2). Our data demonstrated that 96% (115/120) of channels from 20 colonoscopes and 20 duodenoscopes evaluated met the ATP benchmark of <200 RLUs. The 5 channels that exceeded 200 RLUs were all elevator guide-wire channels. All 120 of the manually cleaned endoscopes tested had protein and bioburden levels that were compliant with accepted benchmarks for manual cleaning for suction-biopsy, air-water, and auxiliary water channels. Our data confirmed that, by following the endoscope manufacturer's manual cleaning recommendations, 96% of channels in gastrointestinal endoscopes would have <200 RLUs for the ATP test kit evaluated and would meet the accepted clean benchmarks for protein and bioburden. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Castelo-Branco, Morgana T L; Soares, Igor D P; Lopes, Daiana V; Buongusto, Fernanda; Martinusso, Cesonia A; do Rosario, Alyson; Souza, Sergio A L; Gutfilen, Bianca; Fonseca, Lea Mirian B; Elia, Celeste; Madi, Kalil; Schanaider, Alberto; Rossi, Maria Isabel D; Souza, Heitor S P
2012-01-01
Mesenchymal stromal cells (MSCs) were shown to have immunomodulatory activity and have been applied for treating immune-mediated disorders. We compared the homing and therapeutic action of cryopreserved subcutaneous adipose tissue (AT-MSCs) and bone marrow-derived mesenchymal stromal cells (BM-MSCs) in rats with trinitrobenzene sulfonic acid (TNBS)-induced colitis. After colonoscopic detection of inflammation AT-MSCs or BM-MSCs were injected intraperitoneally. Colonoscopic and histologic scores were obtained. Density of collagen fibres and apoptotic rates were evaluated. Cytokine levels were measured in supernatants of colon explants. For cell migration studies MSCs and skin fibroblasts were labelled with Tc-99m or CM-DiI and injected intraperitonealy or intravenously. Intraperitoneal injection of AT-MSCs or BM-MSCs reduced the endoscopic and histopathologic severity of colitis, the collagen deposition, and the epithelial apoptosis. Levels of TNF-α and interleukin-1β decreased, while VEGF and TGF-β did not change following cell-therapy. Scintigraphy showed that MSCs migrated towards the inflamed colon and the uptake increased from 0.5 to 24 h. Tc-99m-MSCs injected intravenously distributed into various organs, but not the colon. Cm-DiI-positive MSCs were detected throughout the colon wall 72 h after inoculation, predominantly in the submucosa and muscular layer of inflamed areas. Intraperitoneally injected cryopreserved MSCs home to and engraft into the inflamed colon and ameliorate TNBS-colitis.
Clinical predictors and gender-wise variations in dyssynergic defecation disorders.
Jain, Mayank; Baijal, Rajiv; Srinivas, Melpakkam; Venkataraman, Jayanthi
2018-06-12
There is insufficient data from India regarding clinical predictors of dyssynergic defecation. To identify demography, symptom, and colonoscopic parameters that can predict dyssynergic defecation (DD) among patients with chronic constipation (CC) and to compare the profile among male and female patients with DD. Data collected from three centers during June 2014 to May 2017 included age, gender, symptom duration, form and consistency of stools, digital examination, colonoscopy, and anorectal manometry (ARM). Patients were grouped based on ARM diagnosis: group I (normal study) and group II (DD). The two groups were compared for demography, symptom profile, and colonoscopy findings. Gender-wise subset analysis was done for those with the normal and abnormal ARM using chi-square and unpaired t tests. Of 236 patients with CC evaluated, 130 (55%) had normal ARM and 106 (45%) had DD. Male sex, straining during defecation, bleeding per rectum, and abnormal colonoscopic diagnosis were significantly more common in group II. While bleeding per rectum and absence of urge to defecate were more common in males (p < 0.02), straining, digital evacuation, and hard stools were commoner in females with DD. Straining during defecation, bleeding per rectum, and abnormal colonoscopy findings were more common in patients with DD. Symptoms of bleeding per rectum and absence of urge to defecate in men and straining during defecation in female patients were significantly associated with DD. Symptoms differ in males and females with DD.
Hyperspectral imaging of colonic polyps in vivo (Conference Presentation)
NASA Astrophysics Data System (ADS)
Clancy, Neil T.; Elson, Daniel S.; Teare, Julian
2017-02-01
Standard endoscopic tools restrict clinicians to making subjective visual assessments of lesions detected in the bowel, with classification results depending strongly on experience level and training. Histological examination of resected tissue remains the diagnostic gold standard, meaning that all detected lesions are routinely removed. This subjects the patient to risk of polypectomy-related injury, and places significant workload and economic burdens on the hospital. An objective endoscopic classification method would allow hyperplastic polyps, with no malignant potential, to be left in situ, or low grade adenomas to be resected and discarded without histology. A miniature multimodal flexible endoscope is proposed to obtain hyperspectral reflectance and dual excitation autofluorescence information from polyps in vivo. This is placed inside the working channel of a conventional colonoscope, with the external scanning and detection optics on a bedside trolley. A blue and violet laser diode pair excite endogenous fluorophores in the respiration chain, while the colonoscope's xenon light source provides broadband white light for diffuse reflectance measurements. A push-broom HSI scanner collects the hypercube. System characterisation experiments are presented, defining resolution limits as well as acquisition settings for optimal spectral, spatial and temporal performance. The first in vivo results in human subjects are presented, demonstrating the clinical utility of the device. The optical properties (reflectance and autofluorescence) of imaged polyps are quantified and compared to the histologically-confirmed tissue type as well as the clinician's visual assessment. Further clinical studies will allow construction of a full robust training dataset for development of classification schemes.
An adequate level of training for technically competent colonoscopic polypectomy.
Boo, Sun-Jin; Jung, Ji Hoon; Park, Jae Ho; Na, Soo-Young; Kim, Seon Ok; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho; Byeon, Jeong-Sik
2015-07-01
The purpose of this study is to investigate the learning curve for colonoscopic polypectomy (CP) by trainee endoscopists. The amount of training required to achieve technical competence for CP is uncertain. The CP times and en bloc resection rates of three experienced colonoscopists were obtained from 240 procedures. These data were compared to those of three gastroenterology trainees who performed 750 CP procedures. A trainee procedure was deemed to be a success if en bloc resection was obtained and the CP time was within twice the median CP time of the experienced colonoscopists. Trainees were deemed to be technically competent when they achieved a CP success rate of greater than or equal to 80%. The median CP times and en bloc resection rates for the experienced colonoscopists and trainees were 79 s (range, 20-301 s) and 99.6% (239/240), and 118 s (range, 36-1051 s) and 95.6% (717/750), respectively. The trainee success rate of CP was 72% (540/750). The success rate of the procedure was associated with increased trainee experience (p = 0.003) and reached 80% after 250 procedures. The CP time significantly decreased (p < 0.001) and en bloc resection rate significantly increased (p = 0.011) as trainee experience accumulated. The level of experience was an independent predictor for successful CP. The achievement of technical competence with CP was associated with an accumulation of approximately 250 procedures. These findings suggest that dedicated education and training programs for CP are warranted.
Using motion capture to assess colonoscopy experience level
Svendsen, Morten Bo; Preisler, Louise; Hillingsoe, Jens Georg; Svendsen, Lars Bo; Konge, Lars
2014-01-01
AIM: To study technical skills of colonoscopists using a Microsoft Kinect™ for motion analysis to develop a tool to guide colonoscopy education. RESULTS: Ten experienced endoscopists (gastroenterologists, n = 2; colorectal surgeons, n = 8) and 11 novices participated in the study. A Microsoft Kinect™ recorded the movements of the participants during the insertion of the colonoscope. We used a modified script from Microsoft to record skeletal data. Data were saved and later transferred to MatLab for analysis and the calculation of statistics. The test was performed on a physical model, specifically the “Kagaku Colonoscope Training Model” (Kyoto Kagaku Co. Ltd, Kyoto, Japan). After the introduction to the scope and colonoscopy model, the test was performed. Seven metrics were analyzed to find discriminative motion patterns between the novice and experienced endoscopists: hand distance from gurney, number of times the right hand was used to control the small wheel of the colonoscope, angulation of elbows, position of hands in relation to body posture, angulation of body posture in relation to the anus, mean distance between the hands and percentage of time the hands were approximated to each other. RESULTS: Four of the seven metrics showed discriminatory ability: mean distance between hands [45 cm for experienced endoscopists (SD 2) vs 37 cm for novice endoscopists (SD 6)], percentage of time in which the two hands were within 25 cm of each other [5% for experienced endoscopists (SD 4) vs 12% for novice endoscopists (SD 9)], the level of the right hand below the sighting line (z-axis) (25 cm for experienced endoscopists vs 36 cm for novice endoscopists, P < 0.05) and the level of the left hand below the z-axis (6 cm for experienced endoscopists vs 15 cm for novice endoscopists, P < 0.05). By plotting the distributions of the percentages for each group, we determined the best discriminatory value between the groups. A pass score was set at the intersection of the distributions, and the consequences of the standard were explored for each test. By using the contrasting group method, we showed a discriminatory value of Z = 1.51 to be the pass/fail value of the data showing discriminatory ability. The pass score allowed all ten experienced endoscopists as well as five novice endoscopists to pass the test. CONCLUSION: Identified metrics can be used to discriminate between experienced and novice endoscopists and to provide non-biased feedback. Whether it is possible to use this tool to train novices in a clinical setting requires further study. PMID:24891932
Inflammatory fibroid polyp of sigmoid colon.
Lifschitz, O; Lew, S; Witz, M; Reiss, R; Griffel, B
1979-01-01
A case of inflammatory fibroid polyp of the sigmoid colon is presented. This is the eight case of this type of polyp in the colon and, to the best of our knowledge, the first one involving the sigmoid and producing intussusception. Symptomatology of the inflamed fibroid polyp in this part of the gut closely simulates gastrointestinal malignancy. The treatment is surgical excision of the polyp, or colonoscopic resection when it is possible. Intraoperative colonoscopy helps the surgeon to localize the lesion and to role out the existence of other lesions.
Kimura, Tomoaki; Yamamoto, Eiichiro; Yamano, Hiro-O; Suzuki, Hiromu; Kamimae, Seiko; Nojima, Masanori; Sawada, Takeshi; Ashida, Masami; Yoshikawa, Kenjiro; Takagi, Ryo; Kato, Ryusuke; Harada, Taku; Suzuki, Ryo; Maruyama, Reo; Kai, Masahiro; Imai, Kohzoh; Shinomura, Yasuhisa; Sugai, Tamotsu; Toyota, Minoru
2012-03-01
Sessile serrated adenomas (SSAs) are known to be precursors of sporadic colorectal cancers (CRCs) with microsatellite instability (MSI), and to be tightly associated with BRAF mutation and the CpG island methylator phenotype (CIMP). Consequently, colonoscopic identification of SSAs has important implications for preventing CRCs, but accurate endoscopic diagnosis is often difficult. Our aim was to clarify which endoscopic findings are specific to SSAs. The morphological, histological and molecular features of 261 specimens from 226 colorectal tumors were analyzed. Surface microstructures were analyzed using magnifying endoscopy. Mutation in BRAF and KRAS was examined by pyrosequencing. Methylation of p16, IGFBP7, MLH1 and MINT1, -2, -12 and -31 was analyzed using bisulfite pyrosequencing. Through retrospective analysis of a training set (n=145), we identified a novel surface microstructure, the Type II open-shape pit pattern (Type II-O), which was specific to SSAs with BRAF mutation and CIMP. Subsequent prospective analysis of an independent validation set (n=116) confirmed that the Type II-O pattern is highly predictive of SSAs (sensitivity, 65.5%; specificity, 97.3%). BRAF mutation and CIMP occurred with significant frequency in Type II-O-positive serrated lesions. Progression of SSAs to more advanced lesions was associated with further accumulation of aberrant DNA methylation and additional morphological changes, including the Type III, IV and V pit patterns. Our results suggest the Type II-O pit pattern is a useful hallmark of the premalignant stage of CRCs with MSI and CIMP, which could serve to improve the efficacy of colonoscopic surveillance.
Lee, Suk-Young; Song, Wan Hee; Oh, Sang Cheul; Min, Byung-Wook; Lee, Sun Il
2018-01-01
Because data as a basis for the determination of proper age and modality for screening of colorectal neoplasms is lacking, we evaluated detection rates and anatomical distribution of colorectal neoplasms according to age in healthy individuals who underwent total colonoscopy for health checkup. A total of 16,100 cases that had received the colonoscopic examination from January to December in 2014 were analyzed. The total number of individuals who received total colonoscopy were divided by the number of individuals harboring colorectal adenoma to calculate the detection rate of colorectal adenoma. Individuals ≤50 years old were classified as young-age group and aged >50 were old-age group. Differences in anatomical locations of colorectal neoplasms were analyzed in the 2 age groups by chi-square test. Risk factors for colorectal adenoma in each age group were analyzed using univariate and multivariate logistic regression analyses. Detection rates of colorectal adenoma were 13.7% in all cases and 12.8% for those in their 40's. The main anatomical location of colorectal adenoma was proximal colon in both age groups (P < 0.001). Hyperplastic polyp was mainly distributed to the distal colon in both age groups (P < 0.001). Distal colon was the major site for colorectal cancer in the old-age group (P = 0.001). Proximal location of neoplasms was a risk factor for colorectal adenoma in both age groups with multivariate analysis. These data could be the bases for earlier initiation of screening for colorectal neoplasms with total colonoscopy to detect clinically significant colorectal polyps.
Bravi, Ivana; Ravizza, Davide; Fiori, Giancarla; Tamayo, Darina; Trovato, Cristina; De Roberto, Giuseppe; Genco, Chiara; Crosta, Cristiano
2016-01-01
Benign anastomotic colonic stenosis sometimes occur after surgery and usually require surgical or endoscopic dilation. Endoscopic dilation of anastomotic colonic strictures by using balloon or bougie-type dilators has been demonstrated to be safe and effective in multiple uncontrolled series. However, few data are available on safety and efficacy of endoscopic electrocautery dilation. The aim of our study was to retrospectively investigate safety and efficacy of endoscopic electrocautery dilation of postsurgical benign anastomotic colonic strictures. Sixty patients (37 women; median age 63.6 years, range 22.6-81.7) with benign anastomotic colonic or rectal strictures treated with endoscopic electrocautery dilation between June 2001 and February 2013 were included in the study. Anastomotic stricture was defined as a narrowed anastomosis through which a standard colonoscope could not be passed. Only annular anastomotic strictures were considered suitable for electrocautery dilation which consisted of radial incisions performed with a precut sphincterotome. Treatment was considered successful if the colonic anastomosis could be passed by a standard colonoscope immediately after dilation. Recurrence was defined as anastomotic stricture reappearance during follow-up. The time interval between colorectal surgery and the first endoscopic evaluation or symptoms development was 7.3 months (1.3-60.7). Electrocautery dilation was successful in all the patients. There were no procedure-related complications. Median follow-up was 35.5 months (2.0-144.0). Anastomotic stricture recurrence was observed in three patients who were successfully treated with electrocautery dilation and Savary dilation. Endoscopic electrocautery dilation is a safe and effective treatment for annular benign anastomotic postsurgical colonic strictures.
Heparin bridge therapy and post-polypectomy bleeding.
Kubo, Toshiyuki; Yamashita, Kentaro; Onodera, Kei; Iida, Tomoya; Arimura, Yoshiaki; Nojima, Masanori; Nakase, Hiroshi
2016-12-07
To identify risk factors for post-polypectomy bleeding (PPB), focusing on antithrombotic agents. This was a case-control study based on medical records at a single center. PPB was defined as bleeding that occurred 6 h to 10 d after colonoscopic polypectomy and required endoscopic hemostasis. As risk factors for PPB, patient-related factors including anticoagulants, antiplatelets and heparin bridge therapy as well as polyp- and procedure-related factors were evaluated. All colonoscopic hot polypectomies, endoscopic mucosal resections and endoscopic submucosal dissections performed between January 2011 and December 2014 were reviewed. PPB occurred in 29 (3.7%) of 788 polypectomies performed during the study period. Antiplatelet or anticoagulant agents were prescribed for 210 (26.6%) patients and were ceased before polypectomy except for aspirin and cilostazol in 19 cases. Bridging therapy using intravenous unfractionated heparin was adopted for 73 patients. The univariate analysis revealed that anticoagulants, heparin bridge, and anticoagulants plus heparin bridge were significantly associated with PPB ( P < 0.0001) whereas antiplatelets and antiplatelets plus heparin were not. None of the other factors including age, gender, location, size, shape, number of resected polyps, prophylactic clipping and resection method were correlated with PPB. The multivariate analysis demonstrated that anticoagulants and anticoagulants plus heparin bridge therapy were significant risk factors for PPB ( P < 0.0001). Of the 29 PPB cases, 4 required transfusions and none required surgery. A thromboembolic event occurred in a patient who took anticoagulant. Patients taking anticoagulants have an increased risk of PPB, even if the anticoagulants are interrupted before polypectomy. Heparin-bridge therapy might be responsible for the increased PPB in patients taking anticoagulants.
Severe chronic iron deficiency anaemia secondary to Trichuris dysentery syndrome - a case report.
Azira N, M S; Zeehaida, M
2012-12-01
Trichuris dysentery syndrome is caused by Trichuris trichiura which contributes to one of the most common helminthic infections in the world. It is associated with heavy colonic infection that manifests as mucoid diarrhoea, rectal bleeding, rectal prolapse, iron deficiency anaemia, and finger clubbing. Here, we report a case of trichuris dysentery syndrome complicated with severe chronic iron deficiency anaemia in a 4-year-old girl who required blood transfusion. The nematode was visualized on stool microscopic and colonoscopic examination. A longer duration of anti-helminthic treatment is required to achieve effective and better outcome.
Computed tomographic findings of trichuriasis
Tokmak, Naime; Koc, Zafer; Ulusan, Serife; Koltas, Ismail Soner; Bal, Nebil
2006-01-01
In this report, we present computed tomographic findings of colonic trichuriasis. The patient was a 75-year-old man who complained of abdominal pain, and weight loss. Diagnosis was achieved by colonoscopic biopsy. Abdominal computed tomography showed irregular and nodular thickening of the wall of the cecum and ascending colon. Although these findings are nonspecific, they may be one of the findings of trichuriasis. These findings, confirmed by pathologic analysis of the biopsied tissue and Kato-Katz parasitological stool flotation technique, revealed adult Trichuris. To our knowledge, this is the first report of colonic trichuriasis indicated by computed tomography. PMID:16830393
Heparin bridge therapy and post-polypectomy bleeding
Kubo, Toshiyuki; Yamashita, Kentaro; Onodera, Kei; Iida, Tomoya; Arimura, Yoshiaki; Nojima, Masanori; Nakase, Hiroshi
2016-01-01
AIM To identify risk factors for post-polypectomy bleeding (PPB), focusing on antithrombotic agents. METHODS This was a case-control study based on medical records at a single center. PPB was defined as bleeding that occurred 6 h to 10 d after colonoscopic polypectomy and required endoscopic hemostasis. As risk factors for PPB, patient-related factors including anticoagulants, antiplatelets and heparin bridge therapy as well as polyp- and procedure-related factors were evaluated. All colonoscopic hot polypectomies, endoscopic mucosal resections and endoscopic submucosal dissections performed between January 2011 and December 2014 were reviewed. RESULTS PPB occurred in 29 (3.7%) of 788 polypectomies performed during the study period. Antiplatelet or anticoagulant agents were prescribed for 210 (26.6%) patients and were ceased before polypectomy except for aspirin and cilostazol in 19 cases. Bridging therapy using intravenous unfractionated heparin was adopted for 73 patients. The univariate analysis revealed that anticoagulants, heparin bridge, and anticoagulants plus heparin bridge were significantly associated with PPB (P < 0.0001) whereas antiplatelets and antiplatelets plus heparin were not. None of the other factors including age, gender, location, size, shape, number of resected polyps, prophylactic clipping and resection method were correlated with PPB. The multivariate analysis demonstrated that anticoagulants and anticoagulants plus heparin bridge therapy were significant risk factors for PPB (P < 0.0001). Of the 29 PPB cases, 4 required transfusions and none required surgery. A thromboembolic event occurred in a patient who took anticoagulant. CONCLUSION Patients taking anticoagulants have an increased risk of PPB, even if the anticoagulants are interrupted before polypectomy. Heparin-bridge therapy might be responsible for the increased PPB in patients taking anticoagulants. PMID:28018108
Pickert, C N; Lorentz, A; Manns, M P; Bischoff, S C
2012-10-01
After consumption of fruits, nuts, and vegetables, several patients with pollen allergy experience gastrointestinal (GI) tract symptoms that are possibly caused by pollen-associated food allergy. The aim of this study was to evaluate the colonoscopic allergen provocation (COLAP) test using the recombinant birch pollen allergen Bet v 1 (rBet v 1) for in vivo diagnosis of pollen-associated food allergy manifesting in the GI tract. Thirty-four patients with a history of adverse reactions to food, GI tract symptoms, and birch pollen pollinosis and five healthy controls underwent COLAP test. Twenty minutes after endoscopic challenge of the cecal mucosa with rBet v 1, the mucosal wheal and flare reaction was registered semiquantitatively, and tissue biopsy specimens were examined for eosinophil mucosal activation. The mucosal reaction to rBet v 1 was correlated with the presence of pollinosis (P = 0.004), history of adverse reaction to Bet v 1-associated food allergens (P = 0.001), and tissue eosinophils' activation (P < 0.001). A wheal and flare reaction in the COLAP test was observed in 13 of 16 patients (81%) with a history of GI tract symptoms associated with the ingestion of Bet v 1-related foods and in four of 18 (22%) patients with a negative history (P < 0.001). The control group did not develop visible mucosal reactions to rBet v 1. Systemic anaphylactic reactions did not occur. The mucosal administration of rBet v 1 by COLAP test provides a new diagnostic tool that might support the diagnosis of Bet v 1-associated food allergy manifesting in the GI tract. © 2012 John Wiley & Sons A/S.
Comparison of tomographic and colonoscopic diagnoses in the presence of colonic wall thickening
İnce, Ali Tüzün; Baysal, Birol; Kayar, Yusuf; Arabacı, Elif; Bilgin, Mehmet; Hamdard, Jamshid; Yay, Adnan; Şentürk, Hakan
2014-01-01
Introduction and objective: Colonic wall thickening is a common condition in a number of benignant and malignant diseases. This study investigated the accuracy of radiological diagnoses in patients diagnosed with colonic wall thickening using multislice CT (MDCT). Materials and Method: Files of patients with colonic wall thickening diagnosed with 64-slice MDCT were reviewed retrospectively. The colonoscopy results of these patients were grouped under neoplastic process (cancer and adenomatous polyp), inflammatory bowel disease (IBD), diverticulitis and other etiology (nonspecific events, ischemic colitis, solitary rectal ulcer, external compression, secondary to volvulus and radiotherapy), and the results were statistically evaluated. p values < 0.05 were considered statistically significant. Results: The study was performed on 505 files (290 males [57.4%], 215 females [42.6%], mean age: 49.15 ± 18.4 years). CT and colonoscopic diagnoses were reviewed and the following CT to colonoscopy ratios was observed: neoplastic process: 44.4% vs. 40.2%; IBD: 42.4% vs. 42.4%; diverticulitis: 4% vs. 4.2%; other etiology: 9.3% vs. 3.2%. Colonoscopy failed to identify pathology in 9.9% of the patients. The sensitivity, specificity, PPV, NPV and accuracy of CT were 95.6%, 90.4%, 87.1%, 96.8% and 92.4%, respectively, in detecting neoplastic processes; 97.2%, 97.9%, 97.2%, 97.9% and 97.6%, respectively, in detecting IBD; 90.5%, 99.8%, 95%, 99.6% and 99.4%, respectively, in detecting diverticulitis, and 50%, 96,7%, 62.5%, 94.6% and 92%, respectively, in detecting other etiology. Conclusion: While, accuracy of 64 slice-CT in diagnosing colonic wall thickenings secondary especially to neoplastic processes, IBD and diverticulitis was significantly higher, but differential diagnosis is challenging in pathologies due to other etiologies. PMID:25550962
Diverticular disease of the colon does not increase risk of repeat C. difficile infection.
Feuerstadt, Paul; Das, Rohit; Brandt, Lawrence J
2013-01-01
Studies have suggested that colonic diverticulosis might increase the likelihood of repeat Clostridium difficile infection (CDI). Our study was designed to compare rates of repeat infection in patients with and without colon diverticula. Patients who had a positive C. difficile toxin assay and colonoscopic evidence of diverticulosis were classified as CDI and diverticulosis (CDI-D), whereas those with a positive toxin assay but no such colonoscopic evidence were classified as CDI and no diverticulosis (CDI-ND). Various clinical and epidemiologic factors were recorded for each patient. Primary outcomes were "relapse" (repeat CDI within 3 mo of initial infection) and "recurrent" infection (repeat CDI≥3 mo after initial infection). Secondary outcomes 30 days after diagnosis were mortality, intensive care unit transfer, and continuous hospitalization. A total of 128 patients were classified as CDI-D, whereas 137 had CDI-ND. There were no significant differences between CDI-D and CDI-ND when comparing frequencies of repeat infection and its subclassifications, relapse or recurrence. There were, however, statistical associations seen between diverticulosis of the ascending colon and increased recurrence rates [hazard ratio (HR): 1.4±0.38, P<0.05] and decreased rates of relapse in diverticular disease of the descending (HR: 0.40±0.46, P<0.05), and sigmoid colon (HR: 0.39±0.49, P<0.05). The ascending colon association is limited by a small patient population. There were no significant differences in any of the 30-day outcomes including intensive care unit requirement, hospitalization stay, or mortality. Patients with diverticular disease of the colon are not at increased risk of repeat CDI.
Li, Yingchao; Mi, Chen; Li, Weizhi; She, Junjun
2016-11-01
Acute appendicitis is the most common abdominal emergency, but the diagnosis of appendicitis remains a challenge. Endoscopic retrograde appendicitis therapy (ERAT) is a new and minimally invasive procedure for the diagnosis and treatment of acute appendicitis. To investigate the diagnostic value of ERAT for acute appendicitis by the combination of colonoscopy and endoscopic retrograde appendicography (ERA). Twenty-one patients with the diagnosis of suspected uncomplicated acute appendicitis who underwent ERAT between November 2014 and January 2015 were included in this study. The main outcomes, imaging findings of acute appendicitis including colonoscopic direct-vision imaging and fluoroscopic ERA imaging, were retrospectively reviewed. Secondary outcomes included mean operative time, mean hospital stay, rate of complication, rate of appendectomy during follow-up period, and other clinical data. The diagnosis of acute appendicitis was established in 20 patients by positive ERA (5 patients) or colonoscopy (1 patient) alone or both (14 patients). The main colonoscopic imaging findings included mucosal inflammation (15/20, 75 %), appendicoliths (14/20, 70 %), and maturation (5/20, 25 %). The key points of ERA for diagnosing acute appendicitis included radiographic changes of appendix (17/20, 85 %), intraluminal appendicoliths (14/20, 70 %), and perforation (1/20, 5 %). Mean operative time of ERAT was 49.7 min, and mean hospital stay was 3.3 days. No patient converted to emergency appendectomy. Perforation occurred in one patient after appendicoliths removal was not severe and did not require invasive procedures. During at least 1-year follow-up period, only one patient underwent laparoscopic appendectomy. ERAT is a valuable procedure of choice providing a precise yield of diagnostic information for patients with suspected acute appendicitis by combination of colonoscopy and ERA.
Shah-Ghassemzadeh, Nicole K; Jackson, Christian S; Juma, David; Strong, Richard M
2017-08-01
Colorectal cancer (CRC) is the second leading cause of cancer deaths in the USA. Despite a recent rise in CRC screening there remains an increasing demand for colonoscopy, yet a limited supply of gastroenterologists who can meet this need. To determine if a mid-career general internist (GIN) could be trained to perform high-quality colonoscopes via an intensive training programme. A GIN trained 2-3 days/week, 4-5 hours/day, for 7 months with an experienced gastroenterologist. Their independent performance was then compared with that of a gastroenterology attending (GA), with and without a gastroenterology fellow (GF). The primary outcome was to compare caecal intubation rates, adenoma detection rates (ADRs), interval CRC rates and complications between the three groups. 989 patients were initially included in the study, and 818 were included in the final analysis. Caecal intubation rates were 95%, 94% and 93% for the GIN, GA+GF and GA, respectively (p=0.31). The overall polyp detection rates were 68%, 39% and 44% among the GIN, GA+GF and GA, respectively (p<0.0001). The ADRs were 56%, 33% and 34% for the GIN, GA+GF and GA, respectively (p<0.0001). Three complications occurred, all within the GA group. No interval cancers were diagnosed within a 5-year surveillance period, across all three groups. The GIN attained high success rates in all quality measures. Training mid-career GINs to perform high-quality screening colonoscopes, through a standardised curriculum, may be a reasonable approach to address the growing demand for colonoscopists. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Modigliani, R; Mary, J Y; Simon, J F; Cortot, A; Soule, J C; Gendre, J P; Rene, E
1990-04-01
One hundred forty-two patients with active colonic or ileocolonic Crohn's disease were included in a multicenter prospective study. Data collection included 28 clinical, biological, and endoscopic items; the latter were recorded according to a standardized colonoscopic protocol; a previously validated endoscopic index of severity was calculated. Oral prednisolone (1 mg/kg body wt per day) was started and maintained until clinical remission and for at least 3 and at most 7 wk. A second clinical biological and endoscopic evaluation was then performed. At initial colonoscopy, mucosal lesions were, by decreasing order of frequency, superficial ulcerations, deep ulcerations, mucosal edema, erythema, pseudopolyps, aphthoid ulcers, ulcerated stenosis, and nonulcerated stenosis (93%, 74%, 48%, 44%, 41%, 35%, 10%, 8%, and 2% of cases, respectively). No correlation was found between the clinical activity index and any of the endoscopical data (lesion frequency and surface, endoscopic severity index). Ninety-two percent of patients underwent clinical remission within 7 wk of treatment. None of the 28 clinical biological and endoscopical items collected just before treatment could predict clinical response to steroids. Only 38 of the 131 patients in clinical remission were also in endoscopic remission. In conclusion, (a) the description and severity of colonoscopic lesions in active Crohn's disease have been quantified; (b) no correlation exists between clinical severity and nature, surface, or severity of endoscopic lesions; (c) Oral prednisolone (1 mg/kg body wt per day) induces a clinical remission in 92% of patients within 7 wk; (d) resistance to steroids cannot be predicted from the data collected before treatment onset; and (e) only 29% of patients in clinical remission also achieve endoscopic remission.
High-tech rural clinics and hospitals in Japan: a comparison to the Japanese average.
Matsumoto, Masatoshi; Okayama, Masanobu; Inoue, Kazuo; Kajii, Eiji
2004-10-01
Japanese medical facilities are noted for being heavily equipped with high-tech equipment compared to other industrialised countries. Rural facilities are anecdotally said to be better equipped than facilities in other areas due to egalitarian health resource diffusion policies by public sectors whose goal is to secure fair access to modern medical technologies among the entire population. To show the technology status of rural practice and compare it to the national level. Nationwide postal survey. Questionnaires were sent to the directors of 1362 public hospitals and clinics (of the 1723 municipalities defined as 'rural' by four national laws). Information was collected about the technologies they possessed. The data were compared with figures from a national census of all hospitals and clinics. A total of 766 facilities responded (an effective response rate of 56%). Rural facilities showed higher possession rates in most comparable technologies than the national level. It is noted that almost all rural hospitals had gastroscopes and colonoscopes and their possession rates of bronchoscopes and dialysis equipment were twice as high as the national level. The discrepancy in possession rates between rural and national was even more remarkable in clinics than in hospitals. Rural clinics owned twice as many abdominal ultrasonographs, and three times as many gastroscopes, colonoscopes, defibrillators and computed tomography scanners as the national level. Rural facilities are equipped with more technology than urban ones. Government-led, tax based, technology diffusion in the entire country seems to have attained its goal. What is already known on this subject: As a general tendency in both developing and developed countries, rural medical facilities are technologically less equipped than their urban counterparts. What does this paper add?: In Japan, rural medical facilities are technologically better equipped than urban facilities.
Lee, Ko-Chao; Lin, Hao; ChangChien, Chan-Chao; Fu, Hung-Chun; Tsai, Ching-Chou; Wu, Chen-Hsuan; Ou, Yu-Che
2017-02-01
To determine the clinical manifestations and optimal management of female patients with advanced colorectal cancer (CRC) metastasis in ovaries mimicking advanced ovarian malignancy. A retrospective medical records review of female patients with primary CRC metastasis to ovaries, which were initially diagnosed as ovarian malignancy, and treated between 2001 and 2013. Clinical presentations, pathologic findings, and treatment outcomes were analyzed. In total, 19 cases were collected in the study through a hospital tumor registry. The mean age of the patients at the time of diagnosis was 45 years (range, 28-63 years). The most common symptoms were abdominal pain or increased abdominal girth (63%). None of them had rectal bleeding. The ratio of cancer antigen-125 to carcinoembryonic antigen was available in 13 out 19 patients (less than 25 in 76.9%). Barium enema or colonoscopic exam was only performed in 10 outpatients. None of them had a positive finding. All 19 patients went for surgery, all of them had ovarian metastasis but only eight of them had bilateral involvement, and 14 of them had carcinomatosis. All patients went for either optimal cytoreduction surgery or suboptimal cytoreduction surgery. The patients who received optimal cytoreduction surgery had a significant better progression-free and overall survival than those who did not. Clinical manifestations of primary CRC with ovarian metastasis may be confused with advanced ovarian cancer. Negative barium enema or colonoscopic exam cannot rule out the possibility of CRC. For patients with a cancer antigen-125 to carcinoembryonic antigen ratio less than 25, 76% are good reference of CRC metastasis to ovaries. Optimal cytoreduction surgery like that used for treating advanced ovarian cancer had a better prognosis than suboptimal cytoreduction colorectal cancer treatment. Copyright © 2017. Published by Elsevier B.V.
The application of percutaneous endoscopic colostomy to the management of obstructed defecation.
Heriot, A G; Tilney, H S; Simson, J N L
2002-05-01
We describe the case of a 52-year woman with a 17-year history of obstructed defecation in whom all other standard treatments had failed and the patient had refused a colostomy. Her symptoms were controlled by percutaneous endoscopic colostomy with antegrade colonic irrigation. A percutaneous endoscopic colostomy tube was placed in the sigmoid colon endoscopically using a colonoscope and the patient irrigated two liters of water through the percutaneous endoscopic colostomy twice each day and was able to successfully evacuate her rectum without excess straining or discomfort. Percutaneous endoscopic colostomy is an alternative option to colostomy in the management of obstructed defecation.
A case of cytomegalovirus colitis following immunosuppressive treatment for pyoderma gangrenosum.
Kikuchi, Hidezumi; Nagamine, Hidehiro; Setoyama, Mitsuru
2005-04-01
We report a case of pyoderma gangrenosum (PG) complicated by cytomegalovirus (CMV)-induced colitis. A 79-year-old woman with PG was treated with corticosteroid and cyclosporin. She had blood in her stool and advancing anemia during the treatment. A colonoscopic biopsy specimen from the colon revealed typical CMV-infected cells with CMV inclusions confirmed by immunohistochemistry. Furthermore, there were many CMV-antigen-positive leukocytes, suggesting an active CMV infection, which is serious in compromised hosts. Although ulcerative colitis and Crohn's disease are well known as complications of PG, CMV enterocolitis should be considered in the differential diagnosis of enterocolitis in immunocompromised patients.
Diagnosis of gastrointestinal bleeding: A practical guide for clinicians
Kim, Bong Sik Matthew; Li, Bob T; Engel, Alexander; Samra, Jaswinder S; Clarke, Stephen; Norton, Ian D; Li, Angela E
2014-01-01
Gastrointestinal bleeding is a common problem encountered in the emergency department and in the primary care setting. Acute or overt gastrointestinal bleeding is visible in the form of hematemesis, melena or hematochezia. Chronic or occult gastrointestinal bleeding is not apparent to the patient and usually presents as positive fecal occult blood or iron deficiency anemia. Obscure gastrointestinal bleeding is recurrent bleeding when the source remains unidentified after upper endoscopy and colonoscopic evaluation and is usually from the small intestine. Accurate clinical diagnosis is crucial and guides definitive investigations and interventions. This review summarizes the overall diagnostic approach to gastrointestinal bleeding and provides a practical guide for clinicians. PMID:25400991
Adverse drug reaction: rosuvastatin as a cause for ischaemic colitis in a 64-year-old woman
Tan, Jackie; Pretorius, Casper Francois; Flanagan, Paul Vincent; Pais, Antonio
2012-01-01
Rosuvastatin (Crestor, AstraZeneca) is a commonly used drug for managing hypercholesterolaemia. It is a very safe medication with mostly acceptable side effects. Rare but serious side effects are not well known. A 64-year-old woman presented with bloody diarrhoea after starting rosuvastatin for hypercholesterolaemia. Stool microscopy and culture ruled out infective causes. Abdominal CT scan revealed normal calibre celiac axis and superior mesenteric artery. Colonoscopic biopsy revealed ischaemic colitis as the final histological diagnosis. The patient is in complete remission after ceasing the medication. Rosuvastatin causing ischaemic colitis should be considered a rare but serious adverse drug reaction. PMID:22744258
Russel, M G; Zeijen, R N; Brummer, R J; de Bruine, A P; van Kroonenburgh, M J; Stockbrügger, R W
1994-01-01
A patient with a 15 year history of diarrhoea of unknown origin is described. Scintigraphy with technetium-99m labelled albumin suggested albumin loss at the terminal ileum and caecum; subsequent colonoscopic biopsies of these macroscopically normal looking areas showed abundant infiltration with eosinophils. A diagnosis of eosinophilic enterocolitis was made. Treatment with prednisolone had good results, but had to be stopped because of severe side effects. Oral cromoglycate and mesalazine were not effective. Budesonide (CIR), a new topically active corticosteroid with very little systemic effects, was at least as effective as prednisolone without producing side effects. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:7959211
Advanced endoscopic imaging to improve adenoma detection
Neumann, Helmut; Nägel, Andreas; Buda, Andrea
2015-01-01
Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092
Yousefi, Mahdi; Mahdavi, Mohammad Reza Vaez; Hosseini, Seyed Mousalreza; Bahrami, Abdollah; Davati, Ali; Kamalinejad, Mohammad; Faghihzadeh, Sograt
2013-01-01
Background: Hemorrhoids complaint is one of the most common problems in most society, especially in Asian countries. Current drug treatment protocols cannot cure the disease, and they are palliative. According to Persian traditional medicine, Commiphora Mukul (CM) resin is a medication choice. Aim: This randomized study was undertaken to evaluate the efficacy and safety of crude CM resin compared to a combination of lactolose and anti-hemorrhoid (LandA) in patients with uncomplicated hemorrhoids grade 1 and 2. Materials and Methods: This trial was carried out on 99 patients with hemorrhoids, in Ghaem and Imam Reaza Hospitals of the Mashhad University of Medical Sciences, Iran. They randomly received CM 3 g/d for 4 weeks (as study group) or LandA (Lactolose syrup in laxative dose for 1 month and anti-hemorrhoid suppository daily for 10 days) as control group. Subjective and objectives variables including painful defecation, flatulence, constipation, gastro-esophageal reflux (GER), dyspepsia, proctorrhagia, anal protrusion, and colonoscopic grading were assessed before, immediately after, and 4 weeks after the treatment period. An intent-to-treat analysis was used. Safety was assessed with evaluation of clinical adverse effects by common toxicity criteria version 4.0. Forty-nine patients were assigned randomly to receive LandA and 50 to receive CM. After 4 weeks, flatulence, dyspepsia, GER, and colonoscopic grading scores significantly decreased in study group, whereas in control group constipation, painful defecation, and proctorrhagia showed better but not significant improvement. After 4-weak follow-up, the rate of constipation, and proctorrhagia also showed significantly improvement in study group. Constipation and proctorrhagia in control group recurred significantly in 4-week follow-up than after the treatment, whereas this recurrence in test group was not seen. Conclusion: CM was more effective than LandA in 4-week treatment of patients with uncomplicated hemorrhoids grade 1 and 2. PMID:24124288
Duc, D L; Ribiollet, A; Dode, X; Ducel, G; Marchetti, B; Calop, J
2001-06-01
In the light of more and more invasive procedures being carried out in digestive endoscopy using sterile devices, it appears necessary to put in place a process of endoscope reprocessing capable of ensuring the complete elimination of micro-organisms contaminating the device. We undertook a study of the microbial efficacy of STERIS SYSTEM 1 (SS1) which purports to achieve this objective. The channels of a gastroscope and a colonoscope were contaminated with suspensions of Pseudomonas aeruginosa, Aspergillus niger and Bacillus subtilis spores. Two procedures were then followed: (1) manual washing only, and (2) treatment in SS1 without prewashing. Recoveries of organisms were made from each channel according to a standard methodology to discover any survivors. Contamination controls we re assessed to measure the logarithmic reduction between the initial contamination and that recovered from the channels. Six cycles per micro-organisms, per type of endoscope, and per type of procedure were carried out. From an initial contamination leve l of 10(6) micro-organisms per endoscope, no micro-organisms were recovered in 35 of the 36 cycles with the SS1. In one cycle with the colonoscope, three B. subtilis organisms were recovered from the channels. Washing only gave microbial reductions which varied according to the micro-organism tested. The maximum reduction with washing alone was by a factor of 10(3 +/- 0.1)for B. subtilis and the minimum reduction factor was 10(3 +/- 0.3)for P. aeruginosa. Considering the results obtained with SS1 without prewashing and the efficacy obtained from washing only, the washing step offers an additional antimicrobial assurance reduction factor of between 10 and 103.1. This study shows that SS1, integrated into an overall reprocessing procedure for digestive endoscopes, is capable of delivering the complete elimination of contaminating micro-organisms in a reduced time and eliminates the toxic risk of reprocessing associated with aldehyde based disinfectants. Copyright 2001 The Hospital Infection Society.
Alfa, M J; Jackson, M
2001-06-01
The objective of this study was to evaluate the efficacy of the cleaning and bacterial killing ability of a new non-enzyme-based formulation (killing detergent solution [KDS]) compared with commercially available enzymatic detergents that included Metrizyme (Metrex Research Division of Sybron Canada Ltd. Morrisburg, Ontario) and Gzyme (Germiphene Corp, Brantford, Ontario). KDS is a hydrogen peroxide-based detergent formulation that combines cleaning efficacy with the ability to kill microorganisms. The KDS formulation helps ensure the protection of the health care worker from infectious risk during the soaking and cleaning stages of medical device reprocessing and reduces the bioburden on devices before sterilization/disinfection. Test organisms that included Enterococcus faecalis, Salmonella choleraesuis, Staphylococcus aureus, and Pseudomonas aeruginosa were suspended in artificial test soil (ATS-B; patent submitted), inoculated at 10(6) colonyforming units per carrier and dried overnight before detergent exposure. The ATS-B mimics the blood, protein, carbohydrate, and endotoxin levels of patient-used medical devices. Plastic lumen carriers and a flexible colonoscope were used for surface and simulated-use testing, respectively. The results for the microbial challenge dried onto polyvinyl chloride (PVC) carriers demonstrated that the ability of KDS to remove protein, blood, carbohydrate, and endotoxin from surface test carriers was as effective as the enzyme detergents that were evaluated. Furthermore, KDS was able to effect approximately a 5-Log(10) reduction in microbial loads with a 3-minute exposure at room temperature, whereas none of the other detergents were as effective. In simulated-use testing of a soiled colonoscope, KDS was significantly better at ensuring microbial killing compared with Gzyme and Metrizyme and was equivalent to the enzymatic detergents in cleaning ability. In summary the KDS has excellent microbial-killing ability in 3-minute exposures at room temperature and cleans as well as the existing enzymatic detergent formulations that were tested.
Colonoscopic Findings in Patients With Incidental Colonic Focal FDG Uptake.
Keyzer, Caroline; Dhaene, Benjamin; Blocklet, Didier; De Maertelaer, Viviane; Goldman, Serge; Gevenois, Pierre Alain
2015-05-01
The purpose of this study was to investigate the nature of FDG-avid and non-FDG-avid lesions detected at colonoscopy in patients presenting with incidental focal colonic FDG uptake at PET/CT. Among 9073 patients who underwent PET/CT over a 4-year period, 82 patients without a history of colonic disease had focal colonic FDG uptake and underwent colonoscopy. In consensus, a radiologist and a nuclear physician read images from these PET/CT examinations. They recorded the location of focal FDG uptake in the colon and associated CT abnormalities and measured maximum standardized uptake value (SUVmax) and metabolic volume (MV). Readings were performed twice--first without and second with knowledge of lesion location at colonoscopy. The final diagnosis was based on colonoscopic findings and histopathologic results categorized into benign, premalignant, or malignant. One hundred seven foci of colonic FDG uptake at PET/CT and 150 lesions at colonoscopy were detected. Among 107 foci of FDG uptake, 65 (61%) corresponded to a lesion at colonoscopy (true-positive findings), and 42 (39%) did not (false-positive findings). Among 150 lesions found at colonoscopy, 85 (57%) were not FDG avid (false-negative findings). The MV of true-positive findings was lower than that of false-positive findings (4.0 ± 0.4 cm(3) vs 6.2 ± 0.7 cm(3); p = 0.006), but SUVmax did not differ (7.4 ± 0.5 vs 7.7 ± 0.5; p = 0.649). Considering the histopathologic categories of the lesions and the false-positive findings, there was no difference in SUVmax (p = 0.103), but MV was lower in premalignant lesions than in false-positive findings (p = 0.005). Focal colonic FDG uptake may indicate the presence of a benign, pre-malignant, or malignant lesion. Subsequent colonoscopy should not be restricted to the colonic site of FDG uptake.
Patient-to-patient transmission of hepatitis C virus (HCV) during colonoscopy diagnosis
2010-01-01
Background No recognized risk factors can be identified in 10-40% of hepatitis C virus (HCV)-infected patients suggesting that the modes of transmission involved could be underestimated or unidentified. Invasive diagnostic procedures, such as endoscopy, have been considered as a potential HCV transmission route; although the actual extent of transmission in endoscopy procedures remains controversial. Most reported HCV outbreaks related to nosocomial acquisition have been attributed to unsafe injection practices and use of multi-dose vials. Only a few cases of likely patient-to-patient HCV transmission via a contaminated colonoscope have been reported to date. Nosocomial HCV infection may have important medical and legal implications and, therefore, possible transmission routes should be investigated. In this study, a case of nosocomial transmission of HCV from a common source to two patients who underwent colonoscopy in an endoscopy unit is reported. Results A retrospective epidemiological search after detection of index cases revealed several potentially infective procedures: sample blood collection, use of a peripheral catheter, anesthesia and colonoscopy procedures. The epidemiological investigation showed breaches in colonoscope reprocessing and deficiencies in the recording of valuable tracing data. Direct sequences from the NS5B region were obtained to determine the extent of the outbreak and cloned sequences from the E1-E2 region were used to establish the relationships among intrapatient viral populations. Phylogenetic analyses of individual sequences from viral populations infecting the three patients involved in the outbreak confirmed the patient pointed out by the epidemiological search as the source of the outbreak. Furthermore, the sequential order in which the patients underwent colonoscopy correlates with viral genetic variability estimates. Conclusions Patient-to-patient transmission of HCV could be demonstrated although the precise route of transmission remained unclear. Viral genetic variability is proposed as a useful tool for tracing HCV transmission, especially in recent transmissions. PMID:20825635
Khoruts, Alexander; Rank, Kevin M.; Newman, Krista M.; Viskocil, Kimberly; Vaughn, Byron P.; Hamilton, Matthew J.; Sadowsky, Michael J.
2017-01-01
BACKGROUND & AIMS A significant fraction of patients with recurrent Clostridium difficile infections (CDI) have inflammatory bowel disease (IBD). Fecal microbiota transplantation (FMT) can break the cycle of CDI recurrence and can be performed without evaluation of the colon. We evaluated the efficacy of colonoscopic FMT in patients with and without IBD, and whether we could identify IBD in patients during this procedure. METHODS We collected clinical meta-data and colonoscopy results from 272 consecutive patients that underwent FMT for recurrent CDI at the University of Minnesota from 2008 through 2015. Patients had at least 2 spontaneous relapses of CDI following their initial episode and did not clear the infection after 1 extended antibiotic regimen. We collected random mucosal biopsies from patients’ right colons to identify lymphocytic or collagenous colitis during the FMT procedure. Failure or success in clearing CDI was determined within or at 2 months after the FMT. RESULTS Of patients undergoing FMT, 15% had established IBD and 2.6% were found to have IBD during the FMT procedure. A single colonoscopic FMT cleared CDI from 74.4% of patients with IBD and 92.1% of patients without IBD (P = .0018). Patients had similar responses to FMT regardless of immunosuppressive therapy. More than one-quarter of patients with IBD (25.6%) had a clinically significant flare of IBD after FMT. Lymphocytic colitis was documented in 7.4% of patients with endoscopically normal colon mucosa; only 3 of these patients (20%) required additional treatment for colitis after clearance of CDI. CONCLUSIONS Based on an analysis of 272 patients, FMT is somewhat less effective in clearing recurrent CDI from patients with IBD, compared with patients without IBD, regardless of immunosuppressive therapy. More than 25% of patients with IBD have a disease flare following FMT. Lymphocytic colitis did not affect the outcome of FMT, but a small fraction of these patients required pharmacologic treatment after the procedure. PMID:26905904
Mueller, Ralf S; Olivry, Thierry
2017-08-30
The gold standard to diagnose adverse food reactions (AFRs) in the dog and cat is currently an elimination diet with subsequent provocation trials. However, those trials are inconvenient and client compliance can be low. Our objective was to systematically review the literature to evaluate in vivo and in vitro tests used to diagnose AFR in small animals. We searched three databases (CAB Abstracts, MEDLINE and Web of Science) for pertinent references on September 16, 2016. Among 71, 544 and 41 articles found in the CAB Abstract, MEDLINE and Web of Science databases, respectively, we selected 22 articles and abstracts from conference proceedings that reported data usable for evaluation of tests for AFR. Serum tests for food-specific IgE and IgG, intradermal testing with food antigens, lymphocyte proliferation tests, fecal food-specific IgE, patch, gastroscopic, and colonoscopic testing were evaluated. Testing for serum food-specific IgE and IgG showed low repeatability and, in dogs, a highly variable accuracy. In cats, the accuracy of testing for food-specific IgE was low. Lymphocyte proliferation tests were more frequently positive and more accurate in animals with AFR, but, as they are more difficult to perform, they remain currently a research tool. All other reported tests were only evaluated by individual studies with small numbers of animals. Negative patch test reactions have a very high negative predictability in dogs and could enable a choice of ingredients for the elimination diet in selected patients. Gastroscopic and colonoscopic testing as well as food-specific fecal IgE or food-specific serum IgG measurements appear less useful. Currently, the best diagnostic procedure to identify AFRs in small animals remains an elimination diet with subsequent provocation trials.
Dietary habits of colorectal neoplasia patients in comparison to their first-degree relatives.
Kajzrlikova, Ivana Mikoviny; Vitek, Petr; Chalupa, Josef; Dite, Petr
2014-05-07
To compare the dietary habits between colorectal neoplasia patients, their first-degree relatives, and unrelated controls. From July 2008 to April 2011, we collected epidemiological data relevant to colorectal cancer from patients with colorectal neoplasias, their first-degree relatives, and also from a control group consisting of people referred for colonoscopy with a negative family history of colorectal cancer and without evidence of neoplasia after colonoscopic examination. The first-degree relatives were divided into two groups following the colonoscopic examination: (1) patients with neoplasia or (2) patients without neoplasia. Dietary habits of all groups were compared. A χ (2) test was used to assess the association between two dichotomous categorical variables. The study groups consisted of 242 patients with colorectal neoplasias (143 men, 99 women; mean age: 64 ± 12 years) and 160 first-degree relatives (66 men, 94 women; mean age: 48 ± 11 years). Fifty-five of the first-degree relatives were found to have a neoplastic lesion upon colonoscopy, while the remaining 105 were without neoplasia. The control group contained 123 individuals with a negative family history for neoplastic lesions (66 men, 57 women; mean age: 54 ± 12 years). Two hypotheses were tested. In the first, the dietary habits of first-degree relatives with neoplasia were more similar to those of patients with neoplasia, while the dietary habits of first-degree relatives without neoplasia were similar to those of the control group. In the second, no sex-related differences in dietary habits were expected between the particular groups. Indeed, no significant differences were observed in the dietary habits between the groups of patients, controls and first-degree relatives with/without neoplastic lesions. Nevertheless, statistically significant sex-related differences were observed in all groups, wherein women had healthier dietary habits than men. In all groups examined, women had healthier dietary habits than men. Modification of screening guidelines according to sex may improve the efficiency of screening programs.
Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N
2013-02-01
Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Cater, Dan; Vyas, Arpita; Vyas, Dinesh
2015-01-01
Colorectal cancer is the second leading cause of mortality in men and women in the United States. While there is a definite advantage regarding the use of colonoscopies in screening, there is still a lack of widespread acceptance of colonoscopy use in the general public. This is evident by the fact that up to 75% of patients diagnosed with colorectal cancer present with locally advanced disease. In order to make colonoscopy and in turn colorectal cancer screening a patient friendly and a comfortable test some changes in tool are necessary. The conventional colonoscope has not changed much since its development. There are several new advances in colorectal screening practices. One of the most promising new advances is the advent of robotic endoscopic techniques. PMID:26380845
Citrullus colocynthis as the Cause of Acute Rectorrhagia
Javadzadeh, Hamid Reza; Davoudi, Farnoush; Valizadegan, Ghasem; Goodarzi, Hasan; Mahmoodi, Sadrollah; Ghane, Mohammad Reza; Faraji, Mehrdad
2013-01-01
Introduction. Citrullus colocynthis Schrad. is a commonly used medicinal plant especially as a hypoglycemic agent. Case Presentation. Four patients with colocynth intoxication are presented. The main clinical feature was acute rectorrhagia preceeded by mucosal diarrhea with tenesmus, which gradually progressed to bloody diarrhea and overt rectorrhagia within 3 to 4 hours. The only colonoscopic observation was mucosal erosion which was completely resolved in follow-up colonoscopy after 14 days. Conclusion. The membranolytic activity of some C. colocynthis ingredients is responsible for the intestinal damage. Patients and herbalists should be acquainted with the proper use and side effects of the herb. Clinicians should also be aware of C. colocynthis as a probable cause of lower GI bleeding in patients with no other suggestive history, especially diabetics. PMID:23819072
Grewal, Suman; LaComb, Joseph F.; Park, Jiyhe; Channer, Breana; Rajapakse, Ramona; Bucobo, Juan Carlos; Buscaglia, Jonathan M.; Monzur, Farah; Chawla, Anupama; Yang, Jie; Robertson, Charlie E.; Frank, Daniel N.; Li, Ellen
2018-01-01
Background Studies of colonoscopic fecal microbiota transplant (FMT) in patients with recurrent CDI, indicate that this is a very effective treatment for preventing further relapses. In order to provide this service at Stony Brook University Hospital, we initiated an open-label prospective study of single colonoscopic FMT among patients with ≥ 2 recurrences of CDI, with the intention of monitoring microbial composition in the recipient before and after FMT, as compared with their respective donor. We also initiated a concurrent open label prospective trial of single colonoscopic FMT of patients with ulcerative colitis (UC) not responsive to therapy, after obtaining an IND permit (IND 15642). To characterize how FMT alters the fecal microbiota in patients with recurrent Clostridia difficile infections (CDI) and/or UC, we report the results of a pilot microbiome analysis of 11 recipients with a history of 2 or more recurrences of C. difficile infections without inflammatory bowel disease (CDI-only), 3 UC recipients with recurrent C. difficile infections (CDI + UC), and 5 UC recipients without a history of C. difficile infections (UC-only). Method V3V4 Illumina 16S ribosomal RNA (rRNA) gene sequencing was performed on the pre-FMT, 1-week post-FMT, and 3-months post-FMT recipient fecal samples along with those collected from the healthy donors. Fitted linear mixed models were used to examine the effects of Group (CDI-only, CDI + UC, UC-only), timing of FMT (Donor, pre-FMT, 1-week post-FMT, 3-months post-FMT) and first order Group*FMT interactions on the diversity and composition of fecal microbiota. Pairwise comparisons were then carried out on the recipient vs. donor and between the pre-FMT, 1-week post-FMT, and 3-months post-FMT recipient samples within each group. Results Significant effects of FMT on overall microbiota composition (e.g., beta diversity) were observed for the CDI-only and CDI + UC groups. Marked decreases in the relative abundances of the strictly anaerobic Bacteroidetes phylum, and two Firmicutes sub-phyla associated with butyrate production (Ruminococcaceae and Lachnospiraceae) were observed between the CDI-only and CDI + UC recipient groups. There were corresponding increases in the microaerophilic Proteobacteria phylum and the Firmicutes/Bacilli group in the CDI-only and CDI + UC recipient groups. At a more granular level, significant effects of FMT were observed for 81 genus-level operational taxonomic units (OTUs) in at least one of the three recipient groups (p<0.00016 with Bonferroni correction). Pairwise comparisons of the estimated pre-FMT recipient/donor relative abundance ratios identified 6 Gammaproteobacteria OTUs, including the Escherichia-Shigella genus, and 2 Fusobacteria OTUs with significantly increased relative abundance in the pre-FMT samples of all three recipient groups (FDR < 0.05), however the magnitude of the fold change was much larger in the CDI-only and CDI + UC recipients than in the UC-only recipients. Depletion of butyrate producing OTUs, such as Faecalibacterium, in the CDI-only and CDI + UC recipients, were restored after FMT. Conclusion The results from this pilot study suggest that the microbial imbalances in the CDI + UC recipients more closely resemble those of the CDI-only recipients than the UC-only recipients. PMID:29385143
Mintz, Michael; Khair, Shanawaj; Grewal, Suman; LaComb, Joseph F; Park, Jiyhe; Channer, Breana; Rajapakse, Ramona; Bucobo, Juan Carlos; Buscaglia, Jonathan M; Monzur, Farah; Chawla, Anupama; Yang, Jie; Robertson, Charlie E; Frank, Daniel N; Li, Ellen
2018-01-01
Studies of colonoscopic fecal microbiota transplant (FMT) in patients with recurrent CDI, indicate that this is a very effective treatment for preventing further relapses. In order to provide this service at Stony Brook University Hospital, we initiated an open-label prospective study of single colonoscopic FMT among patients with ≥ 2 recurrences of CDI, with the intention of monitoring microbial composition in the recipient before and after FMT, as compared with their respective donor. We also initiated a concurrent open label prospective trial of single colonoscopic FMT of patients with ulcerative colitis (UC) not responsive to therapy, after obtaining an IND permit (IND 15642). To characterize how FMT alters the fecal microbiota in patients with recurrent Clostridia difficile infections (CDI) and/or UC, we report the results of a pilot microbiome analysis of 11 recipients with a history of 2 or more recurrences of C. difficile infections without inflammatory bowel disease (CDI-only), 3 UC recipients with recurrent C. difficile infections (CDI + UC), and 5 UC recipients without a history of C. difficile infections (UC-only). V3V4 Illumina 16S ribosomal RNA (rRNA) gene sequencing was performed on the pre-FMT, 1-week post-FMT, and 3-months post-FMT recipient fecal samples along with those collected from the healthy donors. Fitted linear mixed models were used to examine the effects of Group (CDI-only, CDI + UC, UC-only), timing of FMT (Donor, pre-FMT, 1-week post-FMT, 3-months post-FMT) and first order Group*FMT interactions on the diversity and composition of fecal microbiota. Pairwise comparisons were then carried out on the recipient vs. donor and between the pre-FMT, 1-week post-FMT, and 3-months post-FMT recipient samples within each group. Significant effects of FMT on overall microbiota composition (e.g., beta diversity) were observed for the CDI-only and CDI + UC groups. Marked decreases in the relative abundances of the strictly anaerobic Bacteroidetes phylum, and two Firmicutes sub-phyla associated with butyrate production (Ruminococcaceae and Lachnospiraceae) were observed between the CDI-only and CDI + UC recipient groups. There were corresponding increases in the microaerophilic Proteobacteria phylum and the Firmicutes/Bacilli group in the CDI-only and CDI + UC recipient groups. At a more granular level, significant effects of FMT were observed for 81 genus-level operational taxonomic units (OTUs) in at least one of the three recipient groups (p<0.00016 with Bonferroni correction). Pairwise comparisons of the estimated pre-FMT recipient/donor relative abundance ratios identified 6 Gammaproteobacteria OTUs, including the Escherichia-Shigella genus, and 2 Fusobacteria OTUs with significantly increased relative abundance in the pre-FMT samples of all three recipient groups (FDR < 0.05), however the magnitude of the fold change was much larger in the CDI-only and CDI + UC recipients than in the UC-only recipients. Depletion of butyrate producing OTUs, such as Faecalibacterium, in the CDI-only and CDI + UC recipients, were restored after FMT. The results from this pilot study suggest that the microbial imbalances in the CDI + UC recipients more closely resemble those of the CDI-only recipients than the UC-only recipients.
Kaltenbach, T; Friedland, S; Soetikno, R
2008-10-01
Colonoscopy, the "gold standard" screening test for colorectal cancer (CRC), has known diagnostic limitations. Advances in endoscope technology have focused on improving mucosal visualisation. In addition to increased angle of view and resolution features, recent colonoscopes have non-white-light optics, such as narrow band imaging (NBI), to enhance image contrast. We aimed to study the neoplasia diagnostic characteristics of NBI, by comparing the neoplasm miss rate when the colonoscopy was performed under NBI versus white light (WL). Randomised controlled trial. US Veterans hospital. Elective colonoscopy adults. We randomly assigned patients to undergo a colonoscopic examination using NBI or WL. All patients underwent a second examination using WL, as the reference standard. The primary end point was the difference in the neoplasm miss rate, and secondary outcome was the neoplasm detection rate. In 276 tandem colonoscopy patients, there was no significant difference of miss or detection rates between NBI or WL colonoscopy techniques. Of the 135 patients in the NBI group, 17 patients (12.6%; 95% confidence interval (CI) 7.5 to 19.4%) had a missed neoplasm, as compared with 17 of the 141 patients (12.1%; 95% CI 7.2 to 18.6%) in the WL group, with a miss rate risk difference of 0.5% (95% CI -7.2 to 8.3). 130 patients (47%) had at least one neoplasm. Missed lesions with NBI showed similar characteristics to those missed with WL. All missed neoplasms were tubular adenomas, the majority (78%) was < or = 5 mm and none were larger than 1 cm (one-sided 95% CI up to 1%). Nonpolypoid lesions represented 35% (13/37) of missed neoplasms. NBI did not improve the colorectal neoplasm miss rate compared to WL; the miss rate for advanced adenomas was less than 1% and for all adenomas was 12%. The neoplasm detection rates were similar high using NBI or WL; almost a half the study patients had at least one adenoma. Clinicaltrials.gov identifier: NCT00628147.
Bladder urothelial carcinoma extending to rectal mucosa and presenting with rectal bleeding
Aneese, Andrew M; Manuballa, Vinayata; Amin, Mitual; Cappell, Mitchell S
2017-01-01
An 87-year-old-man with prostate-cancer-stage-T1c-Gleason-6 treated with radiotherapy in 1996, recurrent prostate cancer treated with leuprolide hormonal therapy in 2009, and bladder-urothelial-carcinoma in situ treated with Bacillus-Calmette-Guerin and adriamycin in 2010, presented in 2015 with painless, bright red blood per rectum coating stools daily for 5 mo. Rectal examination revealed bright red blood per rectum; and a hard, fixed, 2.5 cm × 2.5 cm mass at the normal prostate location. The hemoglobin was 7.6 g/dL (iron saturation = 8.4%, indicating iron-deficiency-anemia). Abdominopelvic-CT-angiography revealed focal wall thickening at the bladder neck; a mass containing an air cavity replacing the normal prostate; and adjacent rectal invasion. Colonoscopy demonstrated an ulcerated, oozing, multinodular, friable, 2.5 cm × 2.5 cm mass in anterior rectal wall, at the usual prostate location. Histologic and immunohistochemical analysis of colonoscopic biopsies of the mass revealed poorly-differentiated-carcinoma of urothelial origin. At visceral angiography, the right-superior-rectal-artery was embolized to achieve hemostasis. The patient subsequently developed multiple new metastases and expired 13 mo post-embolization. Comprehensive literature review revealed 16 previously reported cases of rectal involvement from bladder urothelial carcinoma, including 11 cases from direct extension and 5 cases from metastases. Patient age averaged 63.7 ± 9.6 years (all patients male). Rectal involvement was diagnosed on average 13.5 ± 11.8 mo after initial diagnosis of bladder urothelial carcinoma. Symptoms included constipation/gastrointestinal obstruction-6, weight loss-5, diarrhea-3, anorexia-3, pencil thin stools-3, tenesmus-2, anorectal pain-2, and other-5. Rectal examination in 9 patients revealed annular rectal constriction-6, and rectal mass-3. The current patient had the novel presentation of daily bright red blood per rectum coating the stools simulating hemorrhoidal bleeding; the novel mechanism of direct bladder urothelial carcinoma extension into rectal mucosa via the prostate; and the novel aforementioned colonoscopic findings underlying the clinical presentation. PMID:28690772
Conservative Management of Colonoscopic Perforation: A Case Report.
Parsa, Hossein; Miroliaee, Arash; Doagoo, Zafar; Sina, Saeed
2017-07-01
Colonoscopy is widely used for the diagnosis, treatment and a follow up of colorectal diseases. Perforation of the large bowel during elective colonoscopy is rare but serious life threatening complication. We report a 51-year-old woman who experienced recto sigmoid perforation during diagnostic colonoscopy. During 8 days of total hospitalization, she spent 3 days in ICU with gastrointestinal rest. The patient was hydrated and took intravenous antibiotics. In take-output and temperature were closely monitored. Serial abdominal examinations were performed to rule out peritonitis. After transferring to surgery ward in the day 4, liquid diet started slowly, and she was ambulated. At the day 8, she was discharged with the good clinical condition. Conservative management of the patients with early diagnosis of perforation and no signs and symptoms of peritonitis or sepsis could be the modality of choice.
Rayamajhi, Sampanna Jung; Gorla, Arun Kumar Reddy; Basher, Rajender Kumar; Sood, Ashwani; Mittal, Bhagwant Rai
2017-01-01
Dermatomyositis is an inflammatory myopathy with the characteristic features of skin rash and myopathy. We here present a known case of dermatomyositis evaluated with 18 F-FDG PET/CT for the presence of any occult malignancy. The scan was negative for the presence of any malignancy. However, it revealed multiple intensely FDG avid colonic strictures that were later proven on colonoscopic biopsy to be ulcerative colitis. Also, a well-known association of bilateral sacroilitis was simultaneously demonstrated on the scan. The present case demonstrates that 18 F-FDG PET/CT imaging can serve as a one-stop shop imaging modality in dermatomyositis by facilitating detection of occult primary if any and by providing insight into other rare systemic associations.
Rayamajhi, Sampanna Jung; Gorla, Arun Kumar Reddy; Basher, Rajender Kumar; Sood, Ashwani; Mittal, Bhagwant Rai
2017-01-01
Dermatomyositis is an inflammatory myopathy with the characteristic features of skin rash and myopathy. We here present a known case of dermatomyositis evaluated with 18F-FDG PET/CT for the presence of any occult malignancy. The scan was negative for the presence of any malignancy. However, it revealed multiple intensely FDG avid colonic strictures that were later proven on colonoscopic biopsy to be ulcerative colitis. Also, a well-known association of bilateral sacroilitis was simultaneously demonstrated on the scan. The present case demonstrates that 18F-FDG PET/CT imaging can serve as a one-stop shop imaging modality in dermatomyositis by facilitating detection of occult primary if any and by providing insight into other rare systemic associations. PMID:28533643
Lubiprostone induced ischemic colitis.
Sherid, Muhammed; Sifuentes, Humberto; Samo, Salih; Deepak, Parakkal; Sridhar, Subbaramiah
2013-01-14
Ischemic colitis accounts for 6%-18% of the causes of acute lower gastrointestinal bleeding. It is often multifactorial and more commonly encountered in the elderly. Several medications have been implicated in the development of colonic ischemia. We report a case of a 54-year old woman who presented with a two-hour history of nausea, vomiting, abdominal pain, and bloody stool. The patient had recently used lubiprostone with close temporal relationship between the increase in the dose and her symptoms of rectal bleeding. The radiologic, colonoscopic and histopathologic findings were all consistent with ischemic colitis. Her condition improved without any serious complications after the cessation of lubiprostone. This is the first reported case of ischemic colitis with a clear relationship with lubiprostone (Naranjo score of 10). Clinical vigilance for ischemic colitis is recommended for patients receiving lubiprostone who are presenting with abdominal pain and rectal bleeding.
Profile of lower gastrointestinal bleeding in children from a tropical country.
Khurana, A K; Saraya, A; Jain, N; Chandra, M; Kulshreshta, R
1998-01-01
Eighty five children were evaluated endoscopically for recurrent lower gastrointestinal (GI) bleeding. The male: female ratio was 2.4:1 with a mean age of 6 years (range 8 months to 2 years). After adequate bowel preparation endoscopic evaluation was done using olympus CF 101 colonoscope. Sedation was given only in two patients. Full length colonoscopy had been done in 16 cases only, to look for extent of disease in 8 cases and to ascertain site of bleeding when no lesion could be seen on sigmoidoscopy. Juvenile polyps were seen in 40 cases, amoebic ulcer in 20, solitary rectal ulcer in 4 and polyposis syndrome in 5 cases. Sigmoidoscopy alone could establish the diagnose in 76 cases. We conclude that flexible sigmoidoscopy alone is safe and adequate in ascertaining the cause of prolonged recurrent lower GI bleeding.
[A Case of Uterine Body Metastasis from Sigmoid Colon Adenocarcinoma].
Mayumi, Katsuyuki; Terakura, Masanobu; Hori, Takaaki; Takemura, Masashi
2017-11-01
We report a case of metastatic carcinoma to the uterine body from a colorectal adenocarcinoma. A 73-year-old woman underwent laparoscopic sigmoidectomy for sigmoid colon carcinoma 2 years before. In the following study, her serum carcinoembryonic antigen level was elevated, and a uterine body tumor invading the rectal wall was detected via enhanced computed tomography. Colonoscopic examination revealed an elevated lesion at the rectum, which was diagnosed as an adenocarcinoma. Based on these results, we diagnosed the uterine tumor as metastatic tumor from the colon carcinoma. Immunostaining was negative for CK7, but positive for CK20. Thus, we confirmed metastasis of the sigmoid colon cancer to the uterus. Metastasis to the female genital tract from extragenital malignancies are rare, and the prognosis is extremely poor. However, some patients attain long-term survival by surgical intervention even in such cases.
Toward an easier indigocarmine chromoendoscopy.
Barret, Maximilien; Camus, Marine; Leblanc, Sarah; Coriat, Romain; Prat, Frédéric; Chaussade, Stanislas
2015-07-10
Indigocarmine chromoendoscopy has been proven to improve the detection of colonic lesions during screening colonoscopy, and is associated with increased adenoma detection rates. Furthermore, it is commonly used to help in the delineation and characterization of colorectal neoplasms. However, it usually requires the use of a spraying catheter that decreases the suction capacity of the endoscope, and is time- consuming. Herein, we report on the feasibility of indigo carmine chromoendoscopy during colonoscopy without using a spraying catheter, with the dye being administered through the air/water channel of the endoscope. Since the suction channel remains free, the air can be exsufflated and the staining then applies uniformly onto the colonic walls with the excess indigocarmine dye being immediately eliminated. In our experience with various types of colonoscopes and cap-assisted colonoscopy, this procedure makes indigocarmine chromoendoscopy much easier and quicker to perform, and might save the use of a spray catheter.
Toward an easier indigocarmine chromoendoscopy
Barret, Maximilien; Camus, Marine; Leblanc, Sarah; Coriat, Romain; Prat, Frédéric; Chaussade, Stanislas
2015-01-01
Indigocarmine chromoendoscopy has been proven to improve the detection of colonic lesions during screening colonoscopy, and is associated with increased adenoma detection rates. Furthermore, it is commonly used to help in the delineation and characterization of colorectal neoplasms. However, it usually requires the use of a spraying catheter that decreases the suction capacity of the endoscope, and is time- consuming. Herein, we report on the feasibility of indigo carmine chromoendoscopy during colonoscopy without using a spraying catheter, with the dye being administered through the air/water channel of the endoscope. Since the suction channel remains free, the air can be exsufflated and the staining then applies uniformly onto the colonic walls with the excess indigocarmine dye being immediately eliminated. In our experience with various types of colonoscopes and cap-assisted colonoscopy, this procedure makes indigocarmine chromoendoscopy much easier and quicker to perform, and might save the use of a spray catheter. PMID:26191349
Primary intestinal lymphangiectasia with generalized warts.
Lee, Soon Jae; Song, Hyun Joo; Boo, Sun-Jin; Na, Soo-Young; Kim, Heung Up; Hyun, Chang Lim
2015-07-21
Primary intestinal lymphangiectasia (PIL) is a rare protein-losing enteropathy with lymphatic leakage into the small intestine. Dilated lymphatics in the small intestinal wall and mesentery are observed in this disease. Laboratory tests of PIL patients revealed hypoalbuminemia, lymphocytopenia, hypogammaglobulinemia and increased stool α-1 antitrypsin clearance. Cell-mediated immunodeficiency is also present in PIL patients because of loss of lymphocytes. As a result, the patients are vulnerable to chronic viral infection and lymphoma. However, cases of PIL with chronic viral infection, such as human papilloma virus-induced warts, are rarely reported. We report a rare case of PIL with generalized warts in a 36-year-old male patient. PIL was diagnosed by capsule endoscopy and colonoscopic biopsy with histological tissue confirmation. Generalized warts were observed on the head, chest, abdomen, back, anus, and upper and lower extremities, including the hands and feet of the patient.
Full-driving soft robotic colonoscope in compliant colon tissue.
Wang, Kundong; Ma, Jiayi; Wang, Feng; Wang, Zhiwu; Yan, Guozheng; Zhou, Yilu
2017-11-01
Robotic colonoscopy is an efficient examination method for finding malignant tumour in its early stage. This research developed a novel robotic endoscope with 13 mm diameter, 105 mm length and 22.3 g weight. A contact biomechanical model is proposed to increase the locomotion safety and efficiency in the soft tissue. The model shows that the friction difference between the robot and the tissue is a key factor to locomotion capability. A soft, full bellow with excellent compatibility was designed to package the robot body. The bellow increased the static friction and decreased the kinetic friction given the change in the contact state. The bellow is divided into three segments. Each segment is composed of a linear locomotor with micromotor, turbine-worm and wire wrapping-sliding mechanism. The robot is tested in in vivo pig colon, which revealed an excellent locomotion capability and safety in soft tissues.
Lee, Kyung Jin; Kim, Jaeyeon; Shin, Dong Hwan; Jung, Jun Oh; Koh, Seokyoung; Kim, Ka Young; Lee, Jae Min
2015-12-01
We report the case of a 20-year-old man with a 2-month history of anal pain and bloody rectal discharge. He was referred to our clinic of gastroenterology for suspected inflammatory bowel disease (IBD). The colonoscopy showed mucosal nodularities on the rectum and an anal tag. Because the colonoscopic findings were not consistent with the typical manifestations of IBD, we took an additional sexual history and performed studies for infectious proctitis, including serologic tests for Chlamydia trachomatis, Neisseria gonorrhoeae, and Treponema pallidum. He had homosexual experience, and the serologic tests and PCR of a rectal swab were positive for C. trachomatis infection. Finally he was diagnosed as having chlamydial proctitis and was treated with intramuscular ceftriaxone 250 mg in a single dose and doxycycline 100 mg orally twice daily for 7 days. After 2 months, he had no lower abdominal symptoms and his endoscopic findings were improved.
Trichuris trichiura infection diagnosed by colonoscopy: case reports and review of literature.
Ok, Kyung-Sun; Kim, You-Sun; Song, Jung-Hoon; Lee, Jin-Ho; Ryu, Soo-Hyung; Lee, Jung-Hwan; Moon, Jeong-Seop; Whang, Dong-Hee; Lee, Hye-Kyung
2009-09-01
Trichuris trichiura, commonly referred to as a whipworm, has a worldwide distribution, particularly among countries with warm, humid climates. In Korea, trichuriasis was a highly prevalent soil-transmitted helminthiasis until the 1970s. However, the nationwide prevalence decreased to 0.02% in 2004 as a result of national control activities and improvement in the socioeconomic status of Koreans. Most infected individuals have no distinct symptoms, if lightly infected. The diagnosis is typically confirmed by detection of T. trichiura eggs on examination of a stool sample; few reports have described detection of the parasite during colonoscopy. Recently, we managed 4 patients with trichuriasis who were diagnosed by detection of the parasite on colonoscopy, and we reviewed the literature on the colonoscopic diagnosis of T. trichiura in Korea. We suggest that colonoscopy might be a useful diagnostic tool, especially when infected by only a few male worms with no eggs in the stool.
Trichuris trichiura Infection Diagnosed by Colonoscopy: Case Reports and Review of Literature
Ok, Kyung-Sun; Song, Jung-Hoon; Lee, Jin-Ho; Ryu, Soo-Hyung; Lee, Jung-Hwan; Moon, Jeong-Seop; Whang, Dong-Hee; Lee, Hye-Kyung
2009-01-01
Trichuris trichiura, commonly referred to as a whipworm, has a worldwide distribution, particularly among countries with warm, humid climates. In Korea, trichuriasis was a highly prevalent soil-transmitted helminthiasis until the 1970s. However, the nationwide prevalence decreased to 0.02% in 2004 as a result of national control activities and improvement in the socioeconomic status of Koreans. Most infected individuals have no distinct symptoms, if lightly infected. The diagnosis is typically confirmed by detection of T. trichiura eggs on examination of a stool sample; few reports have described detection of the parasite during colonoscopy. Recently, we managed 4 patients with trichuriasis who were diagnosed by detection of the parasite on colonoscopy, and we reviewed the literature on the colonoscopic diagnosis of T. trichiura in Korea. We suggest that colonoscopy might be a useful diagnostic tool, especially when infected by only a few male worms with no eggs in the stool. PMID:19724702
Primary intestinal lymphangiectasia with generalized warts
Lee, Soon Jae; Song, Hyun Joo; Boo, Sun-Jin; Na, Soo-Young; Kim, Heung Up; Hyun, Chang Lim
2015-01-01
Primary intestinal lymphangiectasia (PIL) is a rare protein-losing enteropathy with lymphatic leakage into the small intestine. Dilated lymphatics in the small intestinal wall and mesentery are observed in this disease. Laboratory tests of PIL patients revealed hypoalbuminemia, lymphocytopenia, hypogammaglobulinemia and increased stool α-1 antitrypsin clearance. Cell-mediated immunodeficiency is also present in PIL patients because of loss of lymphocytes. As a result, the patients are vulnerable to chronic viral infection and lymphoma. However, cases of PIL with chronic viral infection, such as human papilloma virus-induced warts, are rarely reported. We report a rare case of PIL with generalized warts in a 36-year-old male patient. PIL was diagnosed by capsule endoscopy and colonoscopic biopsy with histological tissue confirmation. Generalized warts were observed on the head, chest, abdomen, back, anus, and upper and lower extremities, including the hands and feet of the patient. PMID:26217101
Lubiprostone induced ischemic colitis
Sherid, Muhammed; Sifuentes, Humberto; Samo, Salih; Deepak, Parakkal; Sridhar, Subbaramiah
2013-01-01
Ischemic colitis accounts for 6%-18% of the causes of acute lower gastrointestinal bleeding. It is often multifactorial and more commonly encountered in the elderly. Several medications have been implicated in the development of colonic ischemia. We report a case of a 54-year old woman who presented with a two-hour history of nausea, vomiting, abdominal pain, and bloody stool. The patient had recently used lubiprostone with close temporal relationship between the increase in the dose and her symptoms of rectal bleeding. The radiologic, colonoscopic and histopathologic findings were all consistent with ischemic colitis. Her condition improved without any serious complications after the cessation of lubiprostone. This is the first reported case of ischemic colitis with a clear relationship with lubiprostone (Naranjo score of 10). Clinical vigilance for ischemic colitis is recommended for patients receiving lubiprostone who are presenting with abdominal pain and rectal bleeding. PMID:23345954
Teranishi, Hideto; Ishimura, Masataka; Koga, Yuuki; Eguchi, Katsuhide; Sonoda, Motoshi; Kobayashi, Tetsuko; Shiraishi, Satoru; Nakashima, Kentaro; Ikegami, Kouji; Aman, Murasaki; Yamamoto, Hidetaka; Takada, Hidetoshi; Ohga, Shouichi
2017-01-01
A 13-year-old boy was admitted to our hospital because of persistent diarrhea, abdominal pain, and bloody stools. The patient had experienced repeated hospitalizations for the treatment of respiratory infections since early childhood. Colonoscopic and pathological studies led to a diagnosis of gut-associated T-cell lymphoproliferative disease (T-cell LPD). Laboratory data showed T-lymphocytopenia (492/µl), increased serum IgG levels (1,984 mg/dl), and low serum antibody titers for specific pathogens. Combined immunodeficiency accompanied by T-LPD suggested the diagnosis of activated PI3Kδ syndrome (APDS). Genetic analyses identified a heterozygous mutation of the PIK3CD gene (c.1573 G to A p.Glu525Lys). Although prednisolone and cyclosporine therapy has controlled the T-cell LPD, this patient awaits allogeneic hematopoietic cell transplantation to achieve a complete cure of his APDS.
Colonic mass movements in idiopathic chronic constipation.
Bassotti, G; Gaburri, M; Imbimbo, B P; Rossi, L; Farroni, F; Pelli, M A; Morelli, A
1988-01-01
As relatively little is known of human colonic motor activity either in health, or in pathological conditions, we investigated mass movements in 14 chronically constipated patients and 18 healthy volunteers. Mass movements were recorded from proximal and distal colon during 24 h (12 noon-12 noon) by a colonoscopically positioned multilumen manometric probe and low compliance infusion system. Patients and controls differed significantly in the number (mean 2.6 (0.7) v 6.1 (0.9) (SE), p = 0.02) and duration (mean 8.2 (1.6) v 14.1 (0.8) s, p = 0.04) of mass movements. The data suggest that one pathophysiological mechanism of constipation may be decreased propulsive activity. A circadian pattern, with a significant difference between day and night distribution, was documented in both groups. The patients reported decreased defecatory stimulus concomitant with the mass movements. Images Fig. 1 PMID:3197990
Rare cause of intestinal obstruction - submucous lipoma of the sigmoid colon.
Andrei, L S; Andrei, A C; Usurelu, D L; Puscasu, L I; Dima, C; Preda, E; Lupescu, I; Herlea, V; Popescu, I
2014-01-01
The lipoma of the colon is a benign and rare tumor. Most lipomas are asymptomatic, their discovery being fortuitous. The diagnosis is ussualy easy by colonoscopy associated with biopsies. The abdominal CT scan also has its role in the diagnostic process and in the assesment of the tumoral extension.The treatment depends essentially on the clinical picture, on the size and location of the lipoma and involves endoscopic or surgical excision. We present the case of a 56 years old woman in which a random colonoscopic and than tomographic diagnosis of a sigmoidian lipoma was made 2 years ago when the patient presented with different symptoms, the submucosal lipoma being small sized at the time; the surgical treatment(sigmoidectomy including the tumor) was currently indicated by the sub-occlusive syndrome and haematochezia, due to the intraluminal proliferation of the tumor. Celsius.
NASA Astrophysics Data System (ADS)
Ding, Hao; Cao, Ming; DuPont, Andrew W.; Scott, Larry D.; Guha, Sushovan; Singhal, Shashideep; Younes, Mamoun; Pence, Isaac; Herline, Alan; Schwartz, David; Xu, Hua; Mahadevan-Jansen, Anita; Bi, Xiaohong
2016-03-01
Inflammatory bowel disease (IBD) is an idiopathic disease that is typically characterized by chronic inflammation of the gastrointestinal tract. Recently much effort has been devoted to the development of novel diagnostic tools that can assist physicians for fast, accurate, and automated diagnosis of the disease. Previous research based on Raman spectroscopy has shown promising results in differentiating IBD patients from normal screening cases. In the current study, we examined IBD patients in vivo through a colonoscope-coupled Raman system. Optical diagnosis for IBD discrimination was conducted based on full-range spectra using multivariate statistical methods. Further, we incorporated several feature selection methods in machine learning into the classification model. The diagnostic performance for disease differentiation was significantly improved after feature selection. Our results showed that improved IBD diagnosis can be achieved using Raman spectroscopy in combination with multivariate analysis and feature selection.
Goudra, Basavana; Singh, Preet Mohinder; Gouda, Gowri; Borle, Anuradha; Carlin, Augustus; Yadwad, Avantika
2016-10-01
Propofol is a popular anesthetic sedative employed in colonoscopy. It is known to increase the patient satisfaction and improve throughput. However, there are concerns among the clinicians with regard to the depth of sedation, as a deeper degree of sedation is known to increase the incidence of aspiration and other adverse events. So we planned to compare the depth of sedation between propofol and non-propofol based sedation in patients undergoing outpatient colonoscopy, as measured by an electroencephalogram (EEG) based monitor SEDLine monitor (SedlineInc., San Diego, CA). The non-randomized prospective observational study was performed in the outpatient gastroenterology suite of the Hospital of the University of Pennsylvania, Philadelphia. Patients included ASA class I-III aged more than 18 years scheduled for colonoscopy under Propofol or non-propofol based sedation. After an institutional review board approval, a written consent was obtained from prospective patients. Sedation (propofol or non-propofol based) was administered by either a certified nurse anesthetist under the supervision of an anesthesiologist (propofol) or a registered endoscopy nurse under the guidance of the endoscopist performing the procedure (non-propofol sedation). Depth of sedation was measured with an EEG based SEDLine monitor. The sedation providers were blinded to the patient state index-the indicator of depth of sedation. PSI (patient state index-SEDLine reading) was documented at colonoscope insertion, removal and at the return of verbal responsiveness after colonoscope withdrawal. Sedation spectrum was retrieved from the data stored on the SEDLine monitor. Patients sedated with propofol experience significantly deeper degrees of sedation at all times during the procedure. Additionally, during significant part of the procedure, they are at PSI levels associated with deep general anesthesia. The group that received propofol was more deeply sedated and had lower PSI values. Lighter propofol titration protocols may lead to improved patient care such as lowering risk of aspiration and hypotension. The role of processed EEG monitors such as the SEDLine monitor to improve sedation protocols remains to be determined. Trial registration We obtained an ethical clearance from the Institute. No trial registration was mandated, as no interventional drug or investigational device were used during the study.
Incomplete colonoscopy: Maximizing completion rates of gastroenterologists
Brahmania, Mayur; Park, Jei; Svarta, Sigrid; Tong, Jessica; Kwok, Ricky; Enns, Robert
2012-01-01
BACKGROUND Cecal intubation is one of the goals of a quality colonoscopy; however, many factors increasing the risk of incomplete colonoscopy have been implicated. The implications of missed pathology and the demand on health care resources for return colonoscopies pose a conundrum to many physicians. The optimal course of action after incomplete colonoscopy is unclear. OBJECTIVES: To assess endoscopic completion rates of previously incomplete colonoscopies, the methods used to complete them and the factors that led to the previous incomplete procedure. METHODS: All patients who previously underwent incomplete colonoscopy (2005 to 2010) and were referred to St Paul’s Hospital (Vancouver, British Columbia) were evaluated. Colonoscopies were re-attempted by a single endoscopist. Patient charts were reviewed retrospectively. RESULTS: A total of 90 patients (29 males) with a mean (± SD) age of 58±13.2 years were included in the analysis. Thirty patients (33%) had their initial colonoscopy performed by a gastroenterologist. Indications for initial colonoscopy included surveillance or screening (23%), abdominal pain (15%), gastrointestinal bleeding (29%), change in bowel habits or constitutional symptoms (18%), anemia (7%) and chronic diarrhea (8%). Reasons for incomplete colonoscopy included poor preparation (11%), pain or inadequate sedation (16%), tortuous colon (30%), diverticular disease (6%), obstructing mass (6%) and stricturing disease (10%). Reasons for incomplete procedures in the remaining 21% of patients were not reported by the referring physician. Eighty-seven (97%) colonoscopies were subsequently completed in a single attempt at the institution. Seventy-six (84%) colonoscopies were performed using routine manoeuvres, patient positioning and a variable-stiffness colonoscope (either standard or pediatric). A standard 160 or 180 series Olympus gastroscope (Olympus, Japan) was used in five patients (6%) to navigate through sigmoid diverticular disease; a pediatric colonoscope was used in six patients (7%) for similar reasons. Repeat colonoscopy on the remaining three patients (3%) failed: all three required surgery for strictures (two had obstructing malignant masses and one had a severe benign obstructing sigmoid diverticular stricture). CONCLUSION: Most patients with previous incomplete colonoscopy can undergo a successful repeat colonoscopy at a tertiary care centre with instruments that are readily available to most gastroenterologists. Other modalities for evaluation of the colon should be deferred until a second attempt is made at an expert centre. PMID:22993727
Park, Hyun Woo; Lee, Hyun Seok; Hwang, Sejin; Lee, Han Sol; Bae, Han-Ik; Yoon, Ghilsuk
2017-04-01
A 31-year-old woman with a 15-year history of Takayasu's arteritis (TA) and a 13-year history of Hashimoto's thyroiditis presented with hematochezia. She received a diagnosis of Sjögren's syndrome at 1 month before her visit to Kyungpook National University Medical Center. Her colonoscopic findings were compatible with a diagnosis of ulcerative colitis (UC). She was treated with oral mesalazine, and her hematochezia symptoms subsequently disappeared. The coexistence of UC and TA has been reported; however, reports on the coexistence of UC and Sjögren's syndrome, or of UC and Hashimoto's thyroiditis are rare. Although the precise etiologies of these diseases are unknown, their presence together suggests that they may have a common pathophysiologic background. Furthermore, in patients with autoimmune or vascular diseases, including TA, systemic manifestations should be assessed with consideration of inflammatory bowel diseases including UC in the presence of gastrointestinal symptoms such as diarrhea and hematochezia.
Kim, Hee Sun; Yoo, Jeong Seon; Han, Seok Joo; Park, Hyojin
2007-01-01
The eventration of diaphragm is usually found incidentally on chest X-ray or sometimes presented as acute gastric volvulus. However, colonic volvulus on splenic flexure area complicated by diaphragmatic eventration is extremely rare. A 25 year old man complained of upper abdominal pain for three days. He had a history of brain injury during infant period, and had epilepsy and mental retardation. Plain chest X-ray showed left diaphragmatic eventration and marked dilatation of colon on splenic flexure area which had not been changed for last three years. Barium enema showed bird beak appearance on distal colon near the splenic flexure. Colonoscopic reduction failed. After decompression with rectal and nasogastric tubes, colonic volvulus was relieved. To prevent the recurrence of volvulus, we performed segmental resection of left colon including splenic flexure area and repaired the left diaphragmatic eventration. After the operation, the patient had no further recurrent episode of volvulus although ileus persisted.
[Colon transverse volvulus; a case report].
Ramírez-Wiella-Schwuchow, G; Villanueva-Sáenz, E; Bolaños-Badillo, L E; García-Hernández, L A
2009-01-01
Colon transverse volvulus is an uncommon pathology which is associate with alterations of the colonic motility, mental disorders and congenital anomalies of the fixation of the colon sistem. Up to 1994, 72 cases has been reported in world-wide literature. To report a case of colon transverse volvulus and the treatment. A female 46 years old who show intense abdominal pain 2 days of evolution. The physical exploration show important abdominal distension and pain in left inferior quadrant. The Rx of abdomen with gas absence in rectal descendent colon and ampula with level and important distension of proximal colon. Colonoscopic study with impossibility to advance endoscopy throw colon transverse by zone of stenosis, wasn't made a contrast study, underwent laparotomy of urgency, it was done right hemicolectomy and ileocoloanastomosis with good evolution and given of discharge fourth postsurgical day. This possibility is due to have in mind diagnoses, the treatment is surgical secondary to a high index of recidivate, nevertheless recommends the colonoscopy study accomplishment in order to discard obstructive injuries mainly cancer.
Leucht, K; Caj, M; Fried, M; Rogler, G; Hausmann, M
2013-09-01
We investigated the role of B cell lymphoma (BCL)-2-interacting mediator of cell death (Bim) for lymphocyte homeostasis in intestinal mucosa. Lymphocytes lacking Bim are refractory to apoptosis. Chronic colitis was induced in Bim-deficient mice (Bim(-/-) ) with dextran sulphate sodium (DSS). Weight loss and colonoscopic score were increased significantly in Bim(-/-) mice compared to wild-type mice. As Bim is induced for the killing of autoreactive cells we determined the role of Bim in the regulation of lymphocyte survival at mucosal sites. Upon chronic dextran sulphate sodium (DSS)-induced colitis, Bim(-/-) animals exhibited an increased infiltrate of lymphocytes into the mucosa compared to wild-type mice. The number of autoreactive T cell receptor (TCR) Vβ8(+) lymphocytes was significantly higher in Bim(-/-) mice compared to wild-type controls. Impaired removal of autoreactive lymphocytes in Bim(-/-) mice upon chronic DSS-induced colitis may therefore contribute to aggravated mucosal inflammation. © 2013 British Society for Immunology.
Automatic colonic lesion detection and tracking in endoscopic videos
NASA Astrophysics Data System (ADS)
Li, Wenjing; Gustafsson, Ulf; A-Rahim, Yoursif
2011-03-01
The biology of colorectal cancer offers an opportunity for both early detection and prevention. Compared with other imaging modalities, optical colonoscopy is the procedure of choice for simultaneous detection and removal of colonic polyps. Computer assisted screening makes it possible to assist physicians and potentially improve the accuracy of the diagnostic decision during the exam. This paper presents an unsupervised method to detect and track colonic lesions in endoscopic videos. The aim of the lesion screening and tracking is to facilitate detection of polyps and abnormal mucosa in real time as the physician is performing the procedure. For colonic lesion detection, the conventional marker controlled watershed based segmentation is used to segment the colonic lesions, followed by an adaptive ellipse fitting strategy to further validate the shape. For colonic lesion tracking, a mean shift tracker with background modeling is used to track the target region from the detection phase. The approach has been tested on colonoscopy videos acquired during regular colonoscopic procedures and demonstrated promising results.
Mizukami, Tomoyuki; Obara, Megumi; Nishikomori, Ryuta; Kawai, Tomoki; Tahara, Yoshihiro; Sameshima, Naoki; Marutsuka, Kousuke; Nakase, Hiroshi; Kimura, Nobuhiro; Heike, Toshio; Nunoi, Hiroyuki
2012-02-01
X-linked anhidrotic ectodermal dysplasia with immunodeficiency (X-EDA-ID) is caused by hypomorphic mutations in the gene encoding nuclear factor-κB essential modulator protein (NEMO). Patients are susceptibile to diverse pathogens due to insufficient cytokine and frequently show severe chronic colitis. An 11-year-old boy with X-EDA-ID was hospitalized with autoimmune symptoms and severe chronic colitis which had been refractory to immunosuppressive drugs. Since tumor necrosis factor (TNF) α is responsible for the pathogenesis of NEMO colitis according to intestinal NEMO and additional TNFR1 knockout mice studies, and high levels of TNFα-producing mononuclear cells were detected in the patient due to the unexpected gene reversion mosaicism of NEMO, an anti-TNFα monoclonal antibody was administered to ameliorate his abdominal symptoms. Repeated administrations improved his colonoscopic findings as well as his dry skin along with a reduction of TNFα-expressing T cells. These findings suggest TNF blockade therapy is of value for refractory NEMO colitis with gene reversion.
The herbal medicine Dai-Kenchu-To directly stimulates colonic motility.
Kawahara, Hidejiro; Yanaga, Katsuhiko
2009-01-01
Dai-kenchu-to (DKT) has attracted attention as a drug that improves the symptoms of postoperative ileus. However, the detailed mechanism of its action still remains unknown. The effect of DKT on colonic motility was herein evaluated using an original method. Eight healthy male volunteers who understood the purpose of this study were enrolled. Dai-kenchu-to (5 g) was dissolved in saline and administered into the cecum using a colonoscope until the ascending colon became distended. Colonic motility was observed by extrasomatic ultrasonography for 30 min. Colonic contractions were observed 129.4 (range 110-145) s after DKT administration into the ascending colon. Every segment in the right colon divided by the crescentic folds contracted independently. On the other hand, no colonic contractions were observed in the right colon after saline solution alone was administered to the ascending colon. In conclusion, DKT stimulates colonic motility immediately after administration, in the same manner as it does for the upper alimentary tract.
MRI facilitated a diagnosis of endometriosis of the rectum.
Eguchi, S; Komuta, K; Haraguchi, M; Furui, J; Kanematsu, T
2000-01-01
A 51-year-old pre-menopausal Japanese woman suffering from chronic lower abdominal pain was referred to our hospital. A barium enema showed a stenotic lesion in the recto-sigmoid region, and a pelvic computed axial tomography (CAT) scan revealed a thickened rectal wall. A colonoscopic examination showed the rectum to be constrictive, but the mucosa appeared to be intact. Magnetic resonance imaging (MRI) with T1 high-intensity revealed a cystic lesion in the thickened wall of the rectum, which led us to suspect possible bowel endometriosis. Part of the biopsy specimen showed endometrial epithelium within the interstitial layer of histologically normal mucosa; finally, endometriosis of the rectum was diagnosed. The patient became asymptomatic after the initiation of hormonal treatment and later experienced spontaneous menopause. MRI was effective for diagnosis and the patient did not undergo unnecessary laparotomy. Although bowel endometriosis is generally diagnosed by means of resected specimens, in our patient, diagnosis was made using MRI and biopsy, and hormonal therapy had an effective role as a bridge to menopause.
Ischemic colitis induced by the newly reformulated multicomponent weight-loss supplement Hydroxycut®
Sherid, Muhammed; Samo, Salih; Sulaiman, Samian; Gaziano, Joseph H
2013-01-01
Ischemic colitis accounts for 6%-18% of causes of acute lower gastrointestinal bleeding. It is more often multifactorial and more common in elderly. Drugs are considered important causative agents of this disease with different mechanisms. In this paper, we describe a 37-year-old otherwise healthy female presented with sudden onset diffuse abdominal pain and bloody stool. Radiologic, colonoscopic and histopathologic findings were all consistent with ischemic colitis. Her only suspected factor was hydroxycut which she had been taking for a period of 1 mo prior to her presentation. Her condition improved uneventfully after cessation of hydroxycut, bowel rest, intravenous hydration, and antibiotics. This is a first case of ischemic colitis with clear relationship with hydroxycut use (Naranjo score of 7). Our case demonstrates the importance of questioning patients regarding the usage of dietary supplements; especially since many patients consider them safe and do not disclose their use voluntarily to their physicians. Hydroxycut has to be considered as a potential trigger for otherwise unexplained ischemic colitis. PMID:23596542
Lin, Pei-Chiang; Chen, Jinn-Shiun; Deng, Po; Wang, Chih-Wei; Huang, Chiung-Huei; Tang, Reiping; Chiang, Jy-Ming; Yeh, Chien-Yuh; Hsieh, Pao-Shiu; Tsai, Wen-Sy; Chiang, Sum-Fu
2016-01-27
Colonic lymphoma is an uncommon presentation of extranodal lymphoma. Colonic mucosa-associated lymphoid tissue lymphoma is a different entity from gastric mucosa-associated lymphoid tissue lymphoma, and very rare. The presentation and management of colonic mucosa-associated lymphoid tissue are highly variable in the literature. We report the case of a 59-year-old Taiwanese man who underwent a colonoscopy after a positive test for fecal occult blood. His past history included hypertension and hyperthyroidism. The colonoscopy revealed an adenomatous polyp and mucosa-associated lymphoid tissue lymphoma. We successfully performed a polypectomy and endoscopic mucosal resection. The lymphoma was staged according to the Ann Arbor system modified by Musshoff as E-I. Our patient showed no lymphoma recurrence over a 3-year follow-up. Endoscopic mucosal resection for colonic mucosa-associated lymphoid tissue lymphoma without disseminated disease may be feasible. We successfully used colonoscopic treatment without adjuvant therapy to treat early-stage pathogen-free colonic mucosa-associated lymphoid tissue lymphoma.
IgG4-related disease of the rectum
Choi, Sung-Bong; Lim, Chul-Hyun; Cha, Myung-Guen
2016-01-01
IgG4-related disease is a relatively new disease entity characterized by elevated serum IgG4 levels and marked infiltration of IgG4-positive plasma cells in lesions. Organ enlargement or nodular lesions consisting of abundant infiltration of lymphocytes and IgG4-positive plasma cells and fibrosis are seen in various organs throughout. We encountered a patient with an inflammatory pseudotumor of the rectum, which was histopathologically confirmed to be an IgG4-related disease. The patient was a 28-year-old woman who had constipation for 3 months. The endoluminal ultrasonography showed a lesion that was heterogeneous and low echogenic in lower rectum. The result of colonoscopic biopsy findings was of chronic proctitis with lymphoid aggregates. For a confirmative diagnosis, excision was performed. Histopathological examination represented plasma cell infiltration and fibrosis. Immunohistochemistry revealed prominence of IgG4-positive plasma cells and confirmed the diagnosis of IgG4-related disease. The patient is currently under observation on low-dose oral prednisolone without relapse. PMID:27186575
High resolution colonoscopy in a bowel cancer screening program improves polyp detection
Banks, Matthew R; Haidry, Rehan; Butt, M Adil; Whitley, Lisa; Stein, Judith; Langmead, Louise; Bloom, Stuart L; O’Bichere, Austin; McCartney, Sara; Basherdas, Kalpesh; Rodriguez-Justo, Manuel; Lovat, Laurence B
2011-01-01
AIM: To compare high resolution colonoscopy (Olympus Lucera) with a megapixel high resolution system (Pentax HiLine) as an in-service evaluation. METHODS: Polyp detection rates and measures of performance were collected for 269 colonoscopy procedures. Five colonoscopists conducted the study over a three month period, as part of the United Kingdom bowel cancer screening program. RESULTS:There were no differences in procedure duration (χ2 P = 0.98), caecal intubation rates (χ2 P = 0.67), or depth of sedation (χ2 P = 0.64). Mild discomfort was more common in the Pentax group (χ2 P = 0.036). Adenoma detection rate was significantly higher in the Pentax group (χ2 test for trend P = 0.01). Most of the extra polyps detected were flat or sessile adenomas. CONCLUSION: Megapixel definition colonoscopes improve adenoma detection without compromising other measures of endoscope performance. Increased polyp detection rates may improve future outcomes in bowel cancer screening programs. PMID:22090787
Zupanc, Christine M; Burgess-Limerick, Robin; Hill, Andrew; Riek, Stephan; Wallis, Guy M; Plooy, Annaliese M; Horswill, Mark S; Watson, Marcus O; Hewett, David G
2015-12-01
Colonoscopy is a difficult cognitive-perceptual-motor task. Designing an appropriate instructional program for such a task requires an understanding of the knowledge, skills and attitudes underpinning the competency required to perform the task. Cognitive task analysis techniques provide an empirical means of deriving this information. Video recording and a think-aloud protocol were conducted while 20 experienced endoscopists performed colonoscopy procedures. "Cued-recall" interviews were also carried out post-procedure with nine of the endoscopists. Analysis of the resulting transcripts employed the constant comparative coding method within a grounded theory framework. The resulting draft competency framework was modified after review during semi-structured interviews conducted with six expert endoscopists. The proposed colonoscopy competency framework consists of twenty-seven skill, knowledge and attitude components, grouped into six categories (clinical knowledge; colonoscope handling; situation awareness; heuristics and strategies; clinical reasoning; and intra- and inter-personal). The colonoscopy competency framework provides a principled basis for the design of a training program, and for the design of formative assessment to gauge progress towards attaining the knowledge, skills and attitudes underpinning the achievement of colonoscopy competence.
Yamamoto, Tetsu; Tajima, Yoshitsugu; Hyakudomi, Ryoji; Hirayama, Takanori; Taniura, Takahito; Ishitobi, Kazunari; Hirahara, Noriyuki
2017-09-21
A 27-year-old man with recurrent right lower quadrant pain was admitted to our hospital. Ultrasonography and computed tomography examination of the abdomen revealed a target sign in the ascending colon, which was compatible with the diagnosis of cecal intussusception. The intussusception was spontaneously resolved at that time, but it relapsed 6 mo later. The patient underwent a successful colonoscopic disinvagination; there was no evidence of neoplastic or inflammatory lesions in the colon and terminal ileum. The patient underwent laparoscopic surgery for recurring cecal intussusception. During laparoscopy, we observed an unfixed cecum on the posterior peritoneum (i.e. a mobile cecum). Thus, we performed laparoscopic appendectomy and cecopexy with a lateral peritoneal flap using a barbed wound suture device. The patient's post-operative course was uneventful, and he continued to do well without recurrence at 10 mo after surgery. Laparoscopic cecopexy using a barbed wound suture device is a simple and reliable procedure that can be the treatment of choice for recurrent cecal intussusception associated with a mobile cecum.
Cecal volvulus caused by endometriosis in a young woman.
Ito, Daisuke; Kaneko, Susumu; Morita, Kouji; Seiichiro, Shimizu; Teruya, Masanori; Kaminishi, Michio
2015-06-24
Cecal volvulus is relatively rare. Moreover, to the best of our knowledge, a case of cecal volvulus caused by endometriosis has not yet been reported. A 41-year-old woman was admitted to our hospital with a 14-day history of subacute intermittent right lower quadrant abdominal pain. Simple abdominal radiography and abdominal computed tomography findings were suggestive of sigmoid volvulus, and she underwent an emergency colonoscopy. Following colonoscopic reduction, the patient's symptoms resolved quickly, and elective laparoscopic surgery was scheduled 2 weeks after admission. Intraoperative examination revealed a significantly distended cecum and ascending colon, which was twisted around a short rope-like adhesion that connected the cecum and the mesentery of the transverse colon, whereas the sigmoid colon was neither twisted nor extended. We laparoscopically performed an ileocecal resection. The postsurgery histopathological examination revealed the presence of endometrial tissue in the short rope-like adhesion. This finding confirmed that cecal volvulus in this patient was caused by endometriosis. Cecal volvulus should be considered in relatively young women who present with atypical right lower abdominal pain. Whenever possible, secondary factors should be evaluated preoperatively, especially in relatively young patients.
Design of a light delivery system for the photodynamic treatment of the Crohn's disease
NASA Astrophysics Data System (ADS)
Gabrecht, Tanja; Borle, Francois; van den Bergh, Hubert; Michetti, Pierre; Ortner, Maria-Anna; Wagnières, Georges
2007-07-01
Crohn's disease is an inflammatory bowel disease originating from an overwhelming response of the mucosal immune system. Low dose photodynamic therapy (PDT) may modify the mucosal immune response and thus serve as a therapy for Crohn's disease. Most patients with Crohn's disease show inflammatory reactions in the terminal ileum or colon where PDT treatment is feasible by low-invasive endoscopic techniques. However, the tube like geometry of the colon, it's folding, and the presences of multiple foci of Crohn's lesions along the colon require the development of adequate light delivery techniques. We present a prototype light delivery system for endoscopic clinical PDT in patients with Crohn's disease. The system is based on a cylindrical light diffuser inserted into a diffusing balloon catheter. Homogenous irradiation is performed with a 4 W diode laser at 635 nm. Light dosimetry is performed using a calibrated integrating sphere. The system can be used with conventional colonoscopes and colonovideoscopes having a 3.8 mm diameter working channel. The feasibility of PDT in colon with our prototype was demonstrated in first clinical trials.
Robust distortion correction of endoscope
NASA Astrophysics Data System (ADS)
Li, Wenjing; Nie, Sixiang; Soto-Thompson, Marcelo; Chen, Chao-I.; A-Rahim, Yousif I.
2008-03-01
Endoscopic images suffer from a fundamental spatial distortion due to the wide angle design of the endoscope lens. This barrel-type distortion is an obstacle for subsequent Computer Aided Diagnosis (CAD) algorithms and should be corrected. Various methods and research models for the barrel-type distortion correction have been proposed and studied. For industrial applications, a stable, robust method with high accuracy is required to calibrate the different types of endoscopes in an easy of use way. The correction area shall be large enough to cover all the regions that the physicians need to see. In this paper, we present our endoscope distortion correction procedure which includes data acquisition, distortion center estimation, distortion coefficients calculation, and look-up table (LUT) generation. We investigate different polynomial models used for modeling the distortion and propose a new one which provides correction results with better visual quality. The method has been verified with four types of colonoscopes. The correction procedure is currently being applied on human subject data and the coefficients are being utilized in a subsequent 3D reconstruction project of colon.
Ulcerative colitis followed by the development of typical intestinal Behçet disease: A case report.
Zhu, Zhenhua; Shu, Xu; Long, Shunhua; Jiang, Xiaozhen; Lu, Nonghua; Zhu, Xuan; Liao, Wangdi
2018-02-01
Intestinal Behçet disease (intestinal BD) and inflammatory bowel disease (IBD) share a lot of characteristics, including genetic background, clinical manifestations, and therapeutic strategies, especially the extraintestinal manifestations, such as oral ulcers, arthralgia, eye lesions, skin lesions, etc, but the coexistence of these 2 diseases are uncommon. Behçet disease with gastrointestinal involvement in ulcerative colitis (UC) patient has been reported in just 1 previous case report, but, which can not be diagnosed as definite intestinal BD based on Korean novel diagnositic criteria due to lacking the typical ileocecal ulcer. We present a 23-year-old woman with ulcerative disease who developed typical intestinal BD, which is the first case report of patient with coexisting UC and typical intestinal BD. This patient was diagnosed as coexistence of intestinal BD and UC base on the clinical manifestations, extra intestinal manifestations and typical colonoscopic findings. Steroid and methotrexate were administered. This patient achieved clinical remission and mucosal healing. Coexistence of intestinal BD and UC is uncommon, and the combination with steroid, methotrexate, and 5-aminosalicylic acids is an effective therapy.
Laser dosimetry planning tool for colonoscopic tumor resection
NASA Astrophysics Data System (ADS)
Pelayo-Fernández, M. L.; Fanjul-Vélez, F.; Salas-García, I.; Zverev, M.; Arce-Diego, J. L.
2016-03-01
Gastrointestinal tumoral pathologies are quite common nowadays. Diseases such as gastric antral vascular ectasia (GAVE) or actinic proctitis may require endoscopic surgery. Argon Plasma Coagulated (APC) or radiofrequency are usually employed. However, they present disadvantages, such as the reduced treated area, magnetic resonance incompatibility, or an uncontrolled ablation depth. Optical surgery could avoid these problems and contribute to a better and controlled treatment result, either ablative or coagulative, in a minimally invasive, non-contact and non-ionizing way. The treatment area could also be increased by adequate optical fiber probe design. In this work laser surgery is analyzed for resection of colonic tumors. A Monte Carlo model is employed to study optical propagation, and an optical ablation approach allows the estimation of the resected volume. The ablation approach is based on plasma-induced ablation, particularly taking into account the freeelectron density generated in the tissue by the pulsed optical source. Several wavelengths, radii and malignant tissue types are considered, either healthy, adenomatous or even coagulated tissues. Optimum source parameters as a function of tumor geometry can be estimated for treatment planning.
Sampling Strategies for Three-Dimensional Spatial Community Structures in IBD Microbiota Research
Zhang, Shaocun; Cao, Xiaocang; Huang, He
2017-01-01
Identifying intestinal microbiota is arguably an important task that is performed to determine the pathogenesis of inflammatory bowel diseases (IBD); thus, it is crucial to collect and analyze intestinally-associated microbiota. Analyzing a single niche to categorize individuals does not enable researchers to comprehensively study the spatial variations of the microbiota. Therefore, characterizing the spatial community structures of the inflammatory bowel disease microbiome is critical for advancing our understanding of the inflammatory landscape of IBD. However, at present there is no universally accepted consensus regarding the use of specific sampling strategies in different biogeographic locations. In this review, we discuss the spatial distribution when screening sample collections in IBD microbiota research. Here, we propose a novel model, a three-dimensional spatial community structure, which encompasses the x-, y-, and z-axis distributions; it can be used in some sampling sites, such as feces, colonoscopic biopsy, the mucus gel layer, and oral cavity. On the basis of this spatial model, this article also summarizes various sampling and processing strategies prior to and after DNA extraction and recommends guidelines for practical application in future research. PMID:28286741
New automatic mode of visualizing the colon via Cine CT
NASA Astrophysics Data System (ADS)
Udupa, Jayaram K.; Odhner, Dewey; Eisenberg, Harvey C.
2001-05-01
Methods of visualizing the inner colonic wall by using CT images has actively been pursued in recent years in an attempt to eventually replace conventional colonoscopic examination. In spite of impressive progress in this direction, there are still several problems, which need satisfactory solutions. Among these, we address three problems in this paper: segmentation, coverage, and speed of rendering. Instead of thresholding, we utilize the fuzzy connectedness framework to segment the colonic wall. Instead of the endoscopic viewing mode and various mapping techniques, we utilize the central line through the colon to generate automatically viewing directions that are enface with respect to the colon wall, thereby avoiding blind spots in viewing. We utilize some modifications of the ultra fast shell rendering framework to ensure fast rendering speed. The combined effect of these developments is that a colon study requires an initial 5 minutes of operator time plus an additional 5 minutes of computational time and subsequently enface renditions are created in real time (15 frames/sec) on a 1 GHz Pentium PC under the Linux operating system.
Endoscope field of view measurement.
Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen
2017-03-01
The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.
Endoscope field of view measurement
Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen
2017-01-01
The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840
Analysis of colonoscopic perforations at a local clinic and a tertiary hospital.
Sagawa, Toshihiko; Kakizaki, Satoru; Iizuka, Haruhisa; Onozato, Yasuhiro; Sohara, Naondo; Okamura, Shinichi; Mori, Masatomo
2012-09-21
To define the clinical characteristics, and to assess the management of colonoscopic complications at a local clinic. A retrospective review of the medical records was performed for the patients with iatrogenic colon perforations after endoscopy at a local clinic between April 2006 and December 2010. Data obtained from a tertiary hospital in the same region were also analyzed. The underlying conditions, clinical presentations, perforation locations, treatment types (operative or conservative) and outcome data for patients at the local clinic and the tertiary hospital were compared. A total of 10 826 colonoscopies, and 2625 therapeutic procedures were performed at a local clinic and 32 148 colonoscopies, and 7787 therapeutic procedures were performed at the tertiary hospital. The clinic had no perforations during diagnostic colonoscopy and 8 (0.3%) perforations were determined to be related to therapeutic procedures. The perforation rates in each therapeutic procedure were 0.06% (1/1609) in polypectomy, 0.2% (2/885) in endoscopic mucosal resection (EMR), and 3.8% (5/131) in endoscopic submucosal dissection (ESD). Perforation rates for ESD were significantly higher than those for polypectomy or EMR (P < 0.01). All of these patients were treated conservatively. On the other hand, three (0.01%) perforation cases were observed among the 24 361 diagnostic procedures performed, and these cases were treated with surgery in a tertiary hospital. Six perforations occurred with therapeutic endoscopy (perforation rate, 0.08%; 1 per 1298 procedures). Perforation rates for specific procedure types were 0.02% (1 per 5500) for polypectomy, 0.17% (1 per 561) for EMR, 2.3% (1 per 43) for ESD in the tertiary hospital. There were no differences in the perforation rates for each therapeutic procedure between the clinic and the tertiary hospital. The incidence of iatrogenic perforation requiring surgical treatment was quite low in both the clinic and the tertiary hospital. No procedure-related mortalities occurred. Performing closure with endoscopic clipping reduced the C-reactive protein (CRP) titers. The mean maximum CRP titer was 2.9 ± 1.6 mg/dL with clipping and 9.7 ± 6.2 mg/dL without clipping, respectively (P < 0.05). An operation is indicated in the presence of a large perforation, and in the setting of generalized peritonitis or ongoing sepsis. Although we did not experience such case in the clinic, patients with large perforations should be immediately transferred to a tertiary hospital. Good relationships between local clinics and nearby tertiary hospitals should therefore be maintained. It was therefore found to be possible to perform endoscopic treatment at a local clinic when sufficient back up was available at a nearby tertiary hospital.
Ell, C; Fischbach, W; Keller, R; Dehe, M; Mayer, G; Schneider, B; Albrecht, U; Schuette, W
2003-04-01
There are conflicting data regarding the optimal bowel preparation for colonoscopy. This study was carried out to compare the efficacy, safety, and tolerability of three widely used bowel lavage solutions: the standard polyethylene glycol-electrolyte solution based on the GoLytely formulation (PEG-EL1; Klean-Prep); a sulphate-free PEG-EL solution based on the NuLytely formulation (PEG-EL2, Endofalk); and a sodium phosphate preparation (NaP, Fleet Phospho-Soda). A total of 185 consecutive patients scheduled for elective colonoscopy were prospectively randomly assigned to undergo pre-colonoscopic bowel cleansing with either 4 l of PEG-EL1 (n=64), 3 l of PEG-EL2 (n=59), or 90 ml of NaP (n=62). The quality of preparatory colonic cleansing for each segment from the rectum to the ascending colon was scored on a five-level rating scale (1, very good to 5, very poor) by endoscopists who were blinded with regard to the type of preparation used. The primary outcome measure for the comparison of treatments was the "worst" score in any of the rated bowel segments. Safety and tolerability were evaluated by means of a symptom questionnaire completed by each patient immediately before the procedure. Of the 185 patients who were randomly assigned to one of the three treatments, 175 underwent colonoscopy and 173 were evaluable with regard to efficacy - 59, 54, and 60 patients treated with PEG-EL1, PEG-EL2, and NaP, respectively. The treatment groups were comparable with regard to the baseline characteristics. PEG-EL1 was statistically significantly superior to the other treatments in relation to the "worst cleansing" score ( P=0.003). In addition, colonoscopic visualization was markedly better in each of the five bowel segments and general "very good" or "good" ratings were achieved in more than 90 % of patients treated with PEG-EL1. The percentages were consistently lower in the other two groups, particularly in the ascending colon. With the exception of the sigmoid, the differences in all segments of the large bowel were statistically significant (P=0.04). Patient satisfaction was comparable between the treatment groups. Adverse events (mainly nausea/vomiting and abdominal pain) and deviations in laboratory values occurred more frequently in the NaP group. Preparatory PEG-EL1 (Klean-Prep) was significantly superior to PEG-EL2 (Endofalk) and NaP (Fleet Phospho-Soda) in achieving effective cleansing of the entire colon prior to colonoscopy. On the basis of these data, PEG-EL1 can be regarded as the "gold standard" for bowel cleansing prior to colonoscopy.
Shiono, Saori; Saito, Tsuyoshi; Fujii, Hiroaki; Arakawa, Atsushi; Nakamura, Takanori; Yao, Takashi
2014-01-01
We report a case of a 44-year-old woman with bilateral ovarian carcinoma that had metastasized from the colon and mimicked primary mucinous cystadenocarcinoma. Macroscopically, both ovarian tumors were large, multiloculated cystic masses with abundant mucinous content. Histologically, they were lined with mucinous epithelium with mild to moderate nuclear atypia and showed stromal invasion and surface involvement. At first, the tumors were diagnosed as bilateral primary ovarian mucinous cystadenocarcinomas. However, three months after surgery, a large villous tumor was discovered in the ascending colon by colonoscopic examination and was surgically resected. Histologically, the colonic tumor was a villous adenomatous tumor with invasive components of mucinous adenocarcinoma composed of well-differentiated adenocarcinoma and exhibited abundant extracellular mucin production. As a villous adenomatous component was present in the mucosal area, the colonic tumor was considered a primary tumor. Therefore, the original diagnosis of bilateral ovarian tumors was revised for consistent with metastasis from the colon carcinoma, in line with the findings of immunohistochemistry and loss of heterozygosity analysis. This case highlights the importance of considering the possibility of metastatic tumors from the gastrointestinal tract in the diagnosis of mucinous ovarian tumors. PMID:24427362
Huang, Zhi-Heng; Song, Zai; Zhang, Ping; Wu, Jie; Huang, Ying
2016-01-01
AIM: To investigate multiple polyps in a Chinese Peutz-Jeghers syndrome (PJS) infant. METHODS: A nine-month-old PJS infant was admitted to our hospital for recurrent prolapsed rectal polyps for one month. The clinical characteristics, a colonoscopic image, the pathological characteristics of the polyps and X-ray images of the intestinal perforation were obtained. Serine threonine-protein kinase 11 (STK11) gene analysis was also performed using a DNA sample from this infant. RESULTS: Here we describe the youngest known Chinese infant with PJS. Five polyps, including a giant polyp of approximately 4 cm × 2 cm in size, were removed from the infant’s intestine. Laparotomy was performed to repair a perforation caused by pneumoperitoneum. The pathological results showed that this child had PJS. Molecular analysis of the STK11 gene further revealed a novel frameshift mutation (c.64_65het_delAT) in exon 1 in this PJS infant. CONCLUSION: The appropriate treatment method for multiple polyps in an infant must be carefully considered. Our results also show that the STK11 gene mutation is the primary cause of PJS. PMID:27004004
Detection of endoscopic looping during colonoscopy procedure by using embedded bending sensors
Bruce, Michael; Choi, JungHun
2018-01-01
Background Looping of the colonoscope shaft during procedure is one of the most common obstacles encountered by colonoscopists. It occurs in 91% of cases with the N-sigmoid loop being the most common, occurring in 79% of cases. Purpose Herein, a novel system is developed that will give a complete three-dimensional (3D) vector image of the shaft as it passes through the colon, to aid the colonoscopist in detecting loops before they form. Patients and methods A series of connected links spans the middle 50% of the shaft, where loops are likely to form. Two potentiometers are attached at each joint to measure angular deflection in two directions to allow for 3D positioning. This 3D positioning is converted into a 3D vector image using computer software. MATLAB software has been used to display the image on a computer monitor. For the different configuration of the colon model, the system determined the looping status. Results Different configurations (N loop, reverse gamma loop, and reverse splenic flexure) of the loops were well defined using 3D vector image. Conclusion The novel sensory system can accurately define the various configuration of the colon during the colonoscopy procedure. PMID:29849469
System for clinical photometric stereo endoscopy
NASA Astrophysics Data System (ADS)
Durr, Nicholas J.; González, Germán.; Lim, Daryl; Traverso, Giovanni; Nishioka, Norman S.; Vakoc, Benjamin J.; Parot, Vicente
2014-02-01
Photometric stereo endoscopy is a technique that captures information about the high-spatial-frequency topography of the field of view simultaneously with a conventional color image. Here we describe a system that will enable photometric stereo endoscopy to be clinically evaluated in the large intestine of human patients. The clinical photometric stereo endoscopy system consists of a commercial gastroscope, a commercial video processor, an image capturing and processing unit, custom synchronization electronics, white light LEDs, a set of four fibers with diffusing tips, and an alignment cap. The custom pieces that come into contact with the patient are composed of biocompatible materials that can be sterilized before use. The components can then be assembled in the endoscopy suite before use. The resulting endoscope has the same outer diameter as a conventional colonoscope (14 mm), plugs into a commercial video processor, captures topography and color images at 15 Hz, and displays the conventional color image to the gastroenterologist in real-time. We show that this system can capture a color and topographical video in a tubular colon phantom, demonstrating robustness to complex geometries and motion. The reported system is suitable for in vivo evaluation of photometric stereo endoscopy in the human large intestine.
Messias, Bruno Amantini; Franchi, Bárbara Freitas; Pontes, Pedro Henrique; Barbosa, Daniel Átila DE Andrade Medeiros; Viana, César Augusto Sanita
2018-01-01
Clostridium difficile infection is a common complication following intestinal dysbiosis caused by abusive antibiotic use. It presents medical importance due to the high rates of recurrence and morbidity. Fecal microbiota transplantation is an effective alternative for the treatment of recurrent and refractory C. difficile infection and consists of introducing the intestinal microbiota from a healthy donor into a patient with this infection. The exact physiological mechanism by which fecal microbiota transplantation alters the intestinal microbiota is not well established, but it is clear that it restores the diversity and structure of the microbiota by promoting increased resistance to colonization by C. difficile. Several routes of transplant administration are being studied and used according to the advantages presented. All forms of application had a high cure rate, and the colonoscopic route was the most used. No relevant complications and adverse events have been documented, and the cost-effectiveness over conventional treatment has proven advantageous. Despite its efficacy, it is not commonly used as initial therapy, and more studies are needed to establish this therapy as the first option in case of refractory and recurrent Clostridium difficileinfection.
Woitzek, Katja; Dusemund, Frank; Müller, Beat
2010-12-01
Recurrent episodes of cutaneous and subcutaneous ulcers, especially in the oral cavity, represent a high psychological and painful burden for the patient. If there in addition are symptoms of arthralgia and/or colitis, an autoimmune disease with vasculitis, particularly a Morbus Behçet has to be considered as a possible differential diagnosis. The therapy therefore would be an immunosuppressive one. Also a wide immunologic diagnostic process has to be started. Furthermore, a chronic inflammatory bowel disease has to be excluded by colonoscopic biopsy. An infectious etiology of the symptoms (viral/bacterial/parasitic) should be investigated by microbiological and laboratory tests. A thrush or a herpes-infection caused by immunosuppression (toxic or due to illness) has to be considered as a further differential diagnosis. Also a precise medical and drug history is very important because of possible toxic adverse effects. Until confirmation of a final diagnosis, only a symptomatic analgetic or antifungal or antiviral therapy in case of a positive thrush or herpes culture respectively should be initiated with respect to the very different kinds of treatment of the diseases included in the differential diagnosis.
Kilickap, Saadettin; Arslan, Cagatay; Rama, Dorina; Yalcin, Suayib
2012-01-01
This study aimed to research the awareness of screening colonoscopy (SC) among patients with colorectal cancer (CRC) and their relatives. A questionnaire form including information and behavior about colonoscopic screening for CRCs of patients and their first-degree relatives (FDRs) was prepared. A total of 406 CRC patients were enrolled into the study, with 1534 FDRs (siblings n: 1381 and parents n: 153) . Positive family history for CRC was found in 12% of the study population. Previous SC was performed in 11% of patients with CRC. Mean age of the patients whose FDRs underwent SC was lower than the patients whose FDRs did not (52 vs 57 years; p<0,001). The frequency of SC in FDRs was 64% in patients diagnosed CRC under 35 years of age. Persons having a positive family history of CRC had SC more often (51 vs 22%, p<0,001). FDRs of patients having a higher educational level and income had SC more frequently. When screening for CRC is planned, elderly subjects, those with family history for CRC, and those with low educational and lower income should be given especial attention in order that they be convinced to undergo screening for CRC.
Valente, Michael A
2018-03-01
Unexpected focal colorectal 18 F-fluorodeoxyglucose uptake has become a common clinical dilemma. The aim of this study was to identify the clinical significance of incidentally detected colorectal lesions on PET/CT scans by comparing positive PET/CT findings with endoscopic and histopathological analysis. A retrospective analysis of a colonoscopy database was reviewed. All patients that underwent colonoscopy secondary to focal incidental uptake on PET/CT were evaluated. PET/CT findings were correlated with endoscopic and histopathological results. 84 patients underwent colonoscopy secondary to incidental focal colorectal uptake on PET/CT. A total of 63 patients had an endoscopic and histological confirmation of the area of abnormality, for a positive predictive value of 75%. Newly diagnosed colorectal carcinoma was discovered in 13 patients (15.4%) and forty-four patients (52.3%) were discovered to have a premalignant lesion. Incidental focal colorectal uptake of 18 F-fluorodeoxyglucose is associated with a substantial risk of underlying neoplastic colorectal lesions. Early identification of these lesions may alter patient management and treatment plans. Copyright © 2017 Elsevier Inc. All rights reserved.
Acromegaly due to a Macroinvasive Plurihormonal Pituitary Adenoma and a Rectal Carcinoid Tumor
Chin, Sang Ouk; Hwang, Jin-Kyung; Rhee, Sang Youl; Chon, Suk; Oh, Seungjoon; Lee, Misu; Pellegata, Natalia S.
2015-01-01
A macroinvasive pituitary adenoma with plurihormonality usually causes acromegaly and hyperprolactinemia, and also accompanies with neurologic symptoms such as visual disturbances. However, its concurrent presentation with a rectal carcinoid tumor is rarely observed. This study reports the history, biochemical, colonoscopic and immunohistochemical results of a 48-year-old female with acromegaly and hyperprolactinemia. Despite the large size and invasive nature of the pituitary adenoma to adjacent anatomical structures, she did not complain of any neurologic symptoms such as visual disturbance or headache. Immunohistochemical staining of the surgical specimen from the pituitary adenoma revealed that the tumor cells were positive for growth hormone (GH), prolactin (PRL), and thyroid stimulating hormone (TSH). Staining for pituitary-specific transcription factor-1 (Pit-1) was shown to be strongly positive, which could have been possibly contributing to the plurihormonality of this adenoma. Colonoscopy found a rectal polyp that was identified to be a carcinoid tumor using immunohistochemical staining. A macroinvasive pituitary adenoma with concomitant rectal carcinoid tumor was secreting GH, PRL, and TSH, which were believed to be in association with over-expression of Pit-1. This is the first case report of double primary tumors comprising a plurihormonal pituitary macroadenoma and rectal carcinoid tumor. PMID:25559714
Clinical experience with CT colonography
NASA Astrophysics Data System (ADS)
Reed, Judd E.; Garry, John L.; Wilson, Lynn A.; Johnson, C. Daniel
2000-04-01
Since the introduction of Computed Tomographic Colonography (CTC) in 1995, many advances in computer equipment and software have become available. Despite these advances, the promise of colon cancer prevention has not been realized. A colorectal screening tool that performs at a high level, is acceptable to patients, and can be performed safely and at low cost holds promise of saving lives in the future. Our institution has performed over two hundred seventy five clinical CTC examinations. These scans, which each entail a supine and a prone acquisition, only differ from our research protocol in the necessity of an expeditious interpretation. Patients arrive for their CTC examination early in the morning following a period of fasting and bowel preparation. If a CTC examination has a positive finding, the patient is scheduled for colonoscopic polypectomy that same morning. To facilitate this, the patients are required to continue fasting until the CTC examination has been interpreted. It is therefore necessary to process the CTC examination very quickly to minimize patient discomfort. A positive CTC result occurred in fifteen percent of examinations. Among these positive results, the specificity has been in excess of ninety five percent. Additionally, life threatening extra-colonic lesions were discovered in two percent of the screened population.
Mikami, Yohei; Kanai, Takanori; Iwasaki, Eisuke; Naganuma, Makoto; Yamagishi, Yoshiyuki; Shimoda, Masayuki; Matsuoka, Katsuyoshi; Hisamatsu, Tadakazu; Iwao, Yasushi; Ogata, Haruhiko; Nakatsuka, Seishi; Mukai, Makio; Hibi, Toshifumi
2012-12-01
Mesenteric venous thrombosis is an insidious disease, with a high mortality rate typically attributed to the long delay in diagnosis. Rapid diagnosis and treatment are important. Here, we present a patient with idiopathic inferior mesenteric venous (IMV) thrombosis. A 65-year-old man presented with constant abdominal pain associated with fever and bloody diarrhea. He was diagnosed with severe ulcerative colitis and was treated with mesalazine and prednisolone. The prednisolone was tapered because of liver dysfunction, and he received total parenteral nutrition for a month. His abdominal pain and bloody diarrhea worsened, and he lost 5 kg of weight. He was then transferred to our institute. Computed tomography showed thickening of the left colon. Colonoscopy showed diffuse colitis with multiple ulcers, large edematous folds, congested mucosa, and stenosis of the sigmoid colon, with sparing of the rectum, raising the possibility of IMV thrombosis. Angiography confirmed IMV thrombosis. Anticoagulation therapy was initiated with intravenous heparin followed by oral warfarin. His abdominal pain and diarrhea resolved, and he was discharged from hospital. Six months later, he remained asymptomatic with normal colonoscopic findings.
McDuffie, Lucas A; Sabesan, Arvind; Allgäeuer, Michael; Xin, Liqiang; Koh, Christopher; Heller, Theo; Davis, Jeremy L; Raffeld, Mark; Miettienen, Markku; Quezado, Martha; Rudloff, Udo
2016-09-01
To evaluate possible colon involvement in the 'gastric adenocarcinoma and proximal polyposis of the stomach' (GAPPS) gastrointestinal polyposis syndrome. Prospective clinicopathological evaluation of two GAPPS families and expression of nuclear β-catenin, p53 and Ki67 measured by immunohistochemistry on endoscopic and surgical specimens from patients with GAPPS. Patients with the GAPPS phenotype were more frequently affected by colonic polyps than patients at risk within the same families (p<0.01). Colonic polyps shared immunohistochemical features of fundic gland polyps and gastric cancers including increased expression of nuclear β-catenin, Ki67 and p53. Both gastric and colonic lesions harboured activating somatic variants of β-catenin signalling. Similarities in expression markers in fundic gland and colonic polyps, together with an enrichment of colonic adenomas in family members affected by GAPPS phenotype compared with family members at risk, support mild colonic involvement of this rare cancer syndrome. Colonoscopic screening might be warranted. #09-C-0079; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat
2018-06-05
Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.
Surveillance of colonic polyps: Are we getting it right?
Bonnington, Stewart N; Rutter, Matthew D
2016-01-01
Colorectal cancer (CRC) is the third most commonly diagnosed cancer worldwide. The identification of colonic polyps can reduce CRC mortality through earlier diagnosis of cancers and the removal of polyps: the precursor lesion of CRC. Following the finding and removal of colonic polyps at an initial colonoscopy, some patients are at an increased risk of developing CRC in the future. This is the rationale for post-polypectomy surveillance colonoscopy. However, not all individuals found to have colonic adenomas have a risk of CRC higher than that of the general population. This review examines the literature on post-polypectomy surveillance including current international clinical guidelines. The potential benefits of surveillance procedures must be weighed against the burden of colonoscopy: resource use, the potential for patient discomfort, and the risk of complications. Therefore surveillance colonoscopy is best utilised in a selected group of individuals at a high risk of developing cancer. Further study is needed into the specific factors conferring higher risk as well as the efficacy of surveillance in mitigating this risk. Such evidence will better inform clinicians and patients of the relative benefits of colonoscopic surveillance for the individual. In addition, the decision to continue with surveillance must be informed by the changing profile of risks and benefits of further procedures with the patient’s advancing age. PMID:26877600
Usefulness of warm water and oil assistance in colonoscopy by trainees.
Park, Sung Chul; Keum, Bora; Kim, Eun Sun; Jung, Eun Suk; Lee, Sehe Dong; Park, Sanghoon; Seo, Yeon Seok; Kim, Yong Sik; Jeen, Yoon Tae; Chun, Hoon Jai; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang
2010-10-01
Success rate of cecal intubation, endoscopist's difficulty, and procedure-related patient pain are still problems for beginners performing colonoscopy. New methods to aid colonoscopic insertion such as warm water instillation and oil lubrication have been proposed. The aim of this study is to evaluate the feasibility of using warm water or oil in colonoscopy. Colonoscopy was performed in 117 unsedated patients by three endoscopists-in-training. Patients were randomly allocated to three groups, using a conventional method with administration of antispasmodics, warm water instillation, and oil lubrication, respectively. Success rate of total intubation within time limit (15 min), cecal intubation time, degree of endoscopist's difficulty, and level of patient discomfort were compared among the three groups. Cecal intubation time was shorter in the warm water group than in the conventional and oil groups. Degree of procedural difficulty was lower in the warm water group, and patient pain score was higher in the oil lubrication group, compared with the other groups. However, there was no significant difference in success rate of intubation within time limit among the three groups. The warm water method is a simple, safe, and feasible method for beginners. Oil lubrication may not be a useful method compared with conventional and warm water method.
Surveillance of colonic polyps: Are we getting it right?
Bonnington, Stewart N; Rutter, Matthew D
2016-02-14
Colorectal cancer (CRC) is the third most commonly diagnosed cancer worldwide. The identification of colonic polyps can reduce CRC mortality through earlier diagnosis of cancers and the removal of polyps: the precursor lesion of CRC. Following the finding and removal of colonic polyps at an initial colonoscopy, some patients are at an increased risk of developing CRC in the future. This is the rationale for post-polypectomy surveillance colonoscopy. However, not all individuals found to have colonic adenomas have a risk of CRC higher than that of the general population. This review examines the literature on post-polypectomy surveillance including current international clinical guidelines. The potential benefits of surveillance procedures must be weighed against the burden of colonoscopy: resource use, the potential for patient discomfort, and the risk of complications. Therefore surveillance colonoscopy is best utilised in a selected group of individuals at a high risk of developing cancer. Further study is needed into the specific factors conferring higher risk as well as the efficacy of surveillance in mitigating this risk. Such evidence will better inform clinicians and patients of the relative benefits of colonoscopic surveillance for the individual. In addition, the decision to continue with surveillance must be informed by the changing profile of risks and benefits of further procedures with the patient's advancing age.
Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing.
Ofstead, Cori L; Wetzler, Harry P; Johnson, Ellen A; Heymann, Otis L; Maust, Thomas J; Shaw, Michael J
2016-11-01
During a study designed to assess endoscope reprocessing effectiveness, a borescope was used to examine lumens and ports. Cloudy, white, viscous fluid was observed inside fully reprocessed gastroscopes and colonoscopes. This fluid resembled simethicone, which is commonly administered to reduce foam and bubbles that impede visualization during gastrointestinal endoscopy. This article describes methods used to determine whether the observed fluid contained simethicone. Photographs of residual fluid were taken using a borescope. Sterile cotton-tipped swabs were used to collect samples of fluid observed in 3 endoscope ports. Samples were evaluated using Fourier transform infrared spectroscopy (FTIR)-attenuated total reflection analysis. Residual fluid was observed inside 19 of 20 endoscopes. Fluid photographed in 8 endoscopes resembled simethicone solutions. FTIR analysis confirmed the presence of simethicone in 2 endoscopes. Fluid containing simethicone remained inside endoscopes despite reprocessing. Simethicone is an inert, hydrophobic substance that may reduce reprocessing effectiveness. Simethicone solutions commonly contain sugars and thickeners, which may contribute to microbial growth and biofilm development. Studies are needed to assess the prevalence of residual moisture and simethicone in endoscopes and determine the impact on reprocessing effectiveness. We recommend minimizing the use of simethicone pending further research into its safety. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Rodriguez-Diaz, Eladio; Castanon, David A; Singh, Satish K; Bigio, Irving J
2011-06-01
Optical spectroscopy has shown potential as a real-time, in vivo, diagnostic tool for identifying neoplasia during endoscopy. We present the development of a diagnostic algorithm to classify elastic-scattering spectroscopy (ESS) spectra as either neoplastic or non-neoplastic. The algorithm is based on pattern recognition methods, including ensemble classifiers, in which members of the ensemble are trained on different regions of the ESS spectrum, and misclassification-rejection, where the algorithm identifies and refrains from classifying samples that are at higher risk of being misclassified. These "rejected" samples can be reexamined by simply repositioning the probe to obtain additional optical readings or ultimately by sending the polyp for histopathological assessment, as per standard practice. Prospective validation using separate training and testing sets result in a baseline performance of sensitivity = .83, specificity = .79, using the standard framework of feature extraction (principal component analysis) followed by classification (with linear support vector machines). With the developed algorithm, performance improves to Se ∼ 0.90, Sp ∼ 0.90, at a cost of rejecting 20-33% of the samples. These results are on par with a panel of expert pathologists. For colonoscopic prevention of colorectal cancer, our system could reduce biopsy risk and cost, obviate retrieval of non-neoplastic polyps, decrease procedure time, and improve assessment of cancer risk.
Rodriguez-Diaz, Eladio; Castanon, David A.; Singh, Satish K.; Bigio, Irving J.
2011-01-01
Optical spectroscopy has shown potential as a real-time, in vivo, diagnostic tool for identifying neoplasia during endoscopy. We present the development of a diagnostic algorithm to classify elastic-scattering spectroscopy (ESS) spectra as either neoplastic or non-neoplastic. The algorithm is based on pattern recognition methods, including ensemble classifiers, in which members of the ensemble are trained on different regions of the ESS spectrum, and misclassification-rejection, where the algorithm identifies and refrains from classifying samples that are at higher risk of being misclassified. These “rejected” samples can be reexamined by simply repositioning the probe to obtain additional optical readings or ultimately by sending the polyp for histopathological assessment, as per standard practice. Prospective validation using separate training and testing sets result in a baseline performance of sensitivity = .83, specificity = .79, using the standard framework of feature extraction (principal component analysis) followed by classification (with linear support vector machines). With the developed algorithm, performance improves to Se ∼ 0.90, Sp ∼ 0.90, at a cost of rejecting 20–33% of the samples. These results are on par with a panel of expert pathologists. For colonoscopic prevention of colorectal cancer, our system could reduce biopsy risk and cost, obviate retrieval of non-neoplastic polyps, decrease procedure time, and improve assessment of cancer risk. PMID:21721830
Goossens, D A M; Jonkers, D M A E; Russel, M G V M; Stobberingh, E E; Stockbrügger, R W
2006-01-15
Studies on probiotics mainly base their results on faecal samples, which may not represent the situation in the mucosa of distal and proximal colon. In a placebo-controlled study, to assess the effect of Lactobacillus plantarum 299v on the bacterial composition of faecal vs. mucosal samples. Twenty-nine patients undergoing colonoscopic examination for polyps consumed a twice-daily drink with or without L. plantarum 299v (10(11) CFU/day) for 2 weeks. Faecal samples were collected before and after consumption. During colonoscopy, biopsies were collected from the ascending colon and rectum. The faecal and mucosal bacterial concentrations and prevalence were determined. L. plantarum 299v significantly increased the concentration of faecal lactic acid bacteria, lactobacilli and clostridia, and was identified in two rectal biopsies but not in the ascending colon biopsies of probiotic-treated subjects. Concentrations and prevalence in ascending colon and rectum biopsies were comparable, but were significantly lower compared with faecal samples. After probiotic consumption, a significant increase in the faecal concentration of lactobacilli was found but concentrations were low in biopsies. The bacterial composition in biopsies of the ascending colon and rectum did not differ based on culture techniques. To further elucidate the modes of action of probiotics, it might be necessary to study differences in colonization with molecular techniques.
Goedert, James J.; Gong, Yangming; Hua, Xing; Zhong, Huanzi; He, Yimin; Peng, Peng; Yu, Guoqin; Wang, Wenjing; Ravel, Jacques; Shi, Jianxin; Zheng, Ying
2015-01-01
Background Screening for colorectal cancer (CRC) and precancerous colorectal adenoma (CRA) can detect curable disease. However, participation in colonoscopy and sensitivity of fecal heme for CRA are low. Methods Microbiota metrics were determined by Illumina sequencing of 16S rRNA genes amplified from DNA extracted from feces self-collected in RNAlater. Among fecal immunochemical test-positive (FIT +) participants, colonoscopically-defined normal versus CRA patients were compared by regression, permutation, and random forest plus leave-one-out methods. Findings Of 95 FIT + participants, 61 had successful fecal microbiota profiling and colonoscopy, identifying 24 completely normal patients, 20 CRA patients, 2 CRC patients, and 15 with other conditions. Phylum-level fecal community composition differed significantly between CRA and normal patients (permutation P = 0.02). Rank phylum-level abundance distinguished CRA from normal patients (area under the curve = 0.767, permutation P = 0.006). CRA prevalence was 59% in phylum-level cluster B versus 20% in cluster A (exact P = 0.01). Most of the difference reflected 3-fold higher median relative abundance of Proteobacteria taxa (Wilcoxon signed-rank P = 0.03, positive predictive value = 67%). Antibiotic exposure and other potential confounders did not affect the associations. Interpretation If confirmed in larger, more diverse populations, fecal microbiota analysis might be employed to improve screening for CRA and ultimately to reduce mortality from CRC. PMID:26288821
A biomaterial-assisted mesenchymal stromal cell therapy alleviates colonic radiation-induced damage.
Moussa, Lara; Pattappa, Girish; Doix, Bastien; Benselama, Sarra-Louiza; Demarquay, Christelle; Benderitter, Marc; Sémont, Alexandra; Tamarat, Radia; Guicheux, Jérôme; Weiss, Pierre; Réthoré, Gildas; Mathieu, Noëlle
2017-01-01
Healthy tissues surrounding abdomino-pelvic tumours can be impaired by radiotherapy, leading to chronic gastrointestinal complications with substantial mortality. Adipose-derived Mesenchymal Stromal Cells (Ad-MSCs) represent a promising strategy to reduce intestinal lesions. However, systemic administration of Ad-MSCs results in low cell engraftment within the injured tissue. Biomaterials, able to encapsulate and withstand Ad-MSCs, can overcome these limitations. A silanized hydroxypropylmethyl cellulose (Si-HPMC) hydrogel has been designed and characterized for injectable cell delivery using the operative catheter of a colonoscope. We demonstrated that hydrogel loaded-Ad-MSCs were viable, able to secrete trophic factors and responsive to the inflammatory environment. In a rat model of radiation-induced severe colonic damage, Ad-MSC + Si-HPMC improve colonic epithelial structure and hyperpermeability compared with Ad-MSCs injected intravenously or locally. This therapeutic benefit is associated with greater engraftment of Si-HPMC-embedded Ad-MSCs in the irradiated colonic mucosa. Moreover, macrophage infiltration near the injection site was less pronounced when Ad-MSCs were embedded in the hydrogel. Si-HPMC induces modulation of chemoattractant secretion by Ad-MSCs that could contribute to the decrease in macrophage infiltrate. Si-HPMC is suitable for cell delivery by colonoscopy and induces protection of Ad-MSCs in the tissue potentiating their therapeutic effect and could be proposed to patients suffering from colon diseases. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Dave, Maneesh; Johnson, Laura A; Walk, Seth T; Young, Vincent B; Stidham, Ryan W; Chaudhary, Meghana N; Funnell, Jessica; Higgins, Peter D R
2011-08-01
The study of intestinal microbiota has been revolutionised by the use of molecular methods, including terminal restriction fragment length polymorphism (T-RFLP) analysis. Microbiota studies of Crohn's disease patients have examined samples from stool or from the neoterminal ileum with a standard biopsy forceps, which could be contaminated by colonic bacteria when the forceps passes through the colonoscope channel. To determine whether sheathed biopsy forceps are able to obtain terminal ileal microbiota samples with less colonic bacterial contamination compared with unsheathed (standard) biopsy forceps. Prospective randomised single-centre study. Four (paired) biopsy specimens were obtained from adjacent locations in the terminal ileum using the sheathed and standard forceps of 27 consecutive subjects undergoing colonoscopy and the microbiota were characterised using T-RFLP. The Bray-Curtis similarity index between samples (sheathed vs unsheathed forceps) was calculated within patients and significant differences were tested for across all patients. There was not a significant difference in the microbial diversity of samples obtained using sheathed versus unsheathed forceps. The difference in microbial diversity between patients was much greater than the variability within patients by proximal versus distal site or by forceps type. T-RFLP is based on PCR amplification, so it is not always sensitive to rare bacterial species. Standard unsheathed forceps appear to be sufficient for microbiota sample collection from the terminal ileum.
[Clinical profile of cytomegalovirus (CMV) enterocolitis in acquired immunodeficiency syndrome].
De Lima, D B; Fernandes, O; Gomes, V R; Da Silva, E J; De Pinho, P R; De Paiva, D D
2000-01-01
To determine the clinical profile of CMV colitis in AIDS patients, comparing clinical, endoscopic parameters and survival time between 2 groups of AIDS patients having chronic diarrhea. Group A being CMV colitis and group B without CMV colitis. 48 patients with diarrhea that lasted more than 30 days, being 27 in Group A and 21 in Group B, were studied. Age, risk factors, interval time between the diagnosis of HIV infection and the beginning of diarrhea, hematochesia, the endoscopic findings and life table in both groups, were analysed. All of them were diagnosed by stool culture and stools for ovum and parasites, along colonoscopy with biopsies. The unpaired t test was used to assess statistical significance of differences observed in the means of continuous and the chi-square with Yates correction for non-parametric variables. The survival curves were assessed by the Kaplan-Meier and the Mantel-Haenszel's tests. A P value of less than 0,05 was considered to indicate statistical significance. The mucosal lesions associated with the CMV infection are typically ulcerative on a background of hemorrhagic erythema 14 (51,8%) p < 0,01. The life table analysis disclosed shorter survival time in the CMV colitis group 0,005> P>0,001. The others studied data did not achieve statistical significance. AIDS patients with CMV colitis have a poorer long-term survival. Among the colonoscopic findings, ulcerations with hemorrhagic background were the most common lesions.
Rawat, David J; Haddad, Munther; Geoghegan, Niamh; Clarke, Simon; Fell, John M
2004-07-01
The antegrade colonic enema is accepted as effective for management of intractable constipation in children when conventional bowel management has failed. This study describes experience with a new, minimally invasive technique, the distal antegrade colonic enema, which involves percutaneous endoscopic colostomy of the left colon. Fifteen children with refractory constipation and soiling who had radiographic evidence of megarectum and/or distal colonic delay were selected for the procedure. The junction of the descending and the sigmoid colon was identified colonoscopically, and the percutaneous endoscopic colostomy tube, through which antegrade distal colonic enema are administered, was inserted. Fourteen children underwent distal percutaneous endoscopic colostomy insertion. The median time required for the procedure was 30 minutes (20-50 minutes). Excluding one child (technical difficulties with percutaneous endoscopic colostomy placement), median post-procedural hospital stay was 4 days (2-27 days). Thirteen children were no longer soiling, and improvement in quality of life was reported at 2 months' follow-up. At 6 months' follow-up, 90% of children were clean during intervals between enemas. All children evaluated at 12 months' follow-up remained clean. Median duration of follow-up was 12.5 months (2-51 months). The distal percutaneous endoscopic colostomy is a simple alternative to established methods for delivery of antegrade enemas. It is less invasive and on reversal leaves only minor scarring.
Associations of Mental Health and Physical Function with Colonoscopy-related Pain.
Yamada, Eiji; Watanabe, Seitaro; Nakajima, Atsushi
2017-01-01
Objective To clarify the effects of mental health and physical function in association with colonoscopy-related pain. Methods The mental health and physical function were evaluated using the Japanese version of the SF-8 Health Survey questionnaire. Poor physical status was defined as a physical component summary (PCS) <40 and poor mental status as a mental component summary (MCS) <40. Pain was assessed using a visual analogue scale (VAS), with significant pain defined as VAS ≥70 mm and insignificant pain as VAS <70 mm. The background and colonoscopic findings were compared in patients with significant and insignificant pain. Patients This study evaluated consecutive Japanese patients who were positive on fecal occult blood tests and underwent total colonoscopy. Results Of the 100 patients, 23 had significant and 77 had insignificant colonoscopy-related pain. A multiple logistic regression analysis showed that MCS <40 [odds ratio (OR) 6.03; 95% confidence interval (CI) 1.41-25.9, p=0.0156], PCS <40 (OR 5.96; 95% CI 1.45-24.5, p=0.0133), and ≥300 seconds to reach the cecum (OR 4.13; 95% CI 1.16-14.7, p=0.0281) were independent risk factors for colonoscopy-related pain. Conclusion The mental health and physical function are important determinants of colonoscopy-related pain. Evaluating the mental health and physical function of patients prior to colonoscopy may effectively predict the degree of colonoscopy-related pain.
Comparison of non-schistosomal rectosigmoid cancer and schistosomal rectosigmoid cancer.
Feng, Hao; Lu, Ai-Guo; Zhao, Xue-Wei; Han, Ding-Pei; Zhao, Jing-Kun; Shi, Lei; Schiergens, Tobias S; Lee, Serene M L; Zhang, Wen-Peng; Thasler, Wolfgang E
2015-06-21
To compare the clinicopathological features of patients with non-schistosomal rectosigmoid cancer and schistosomal rectosigmoid cancer. All the patients with rectosigmoid carcinoma who underwent laparoscopic radical surgical resection in the Shanghai Minimally Invasive Surgical Center at Ruijin Hospital affiliated to Shanghai Jiao-Tong University between October 2009 and October 2013 were included in this study. Twenty-six cases of colonic schistosomiasis diagnosed through colonoscopy and pathological examinations were collected. Symptoms, endoscopic findings and clinicopathological characteristics were evaluated retrospectively. There were no significant differences between patients with and without schistosomiasis in gender, age, CEA, CA19-9, preoperative biopsy findings or postoperative pathology. Patients with rectosigmoid schistosomiasis had a significantly higher CA-125 level and a larger proportion of these patients were at an early tumor stage (P = 0.003). Various morphological characteristics of schistosomiasis combined with rectosigmoid cancer could be found by colonoscopic examination: 46% were fungating mass polyps, 23% were congestive and ulcerative polyps, 23% were cauliflower-like masses, 8% were annular masses. Only 27% of the patients were diagnosed with rectal carcinoma preoperatively after the biopsy. Computed tomography (CT) scans showed thickened intestinal walls combined with linear and tram-track calcifications in 26 patients. Rectosigmoid carcinoma combined with schistosomiasis is associated with higher CA-125 values and early tumor stages. CA-125 and CT scans have a reasonable sensitivity for the accurate diagnosis.
Tikku, Gargi; Jain, Monica; Mridha, Asit; Grover, Rajesh
2014-01-01
Solitary bone plasmacytomas and plasma cell myeloma are clonal proliferations of plasma cells. Many patients with solitary bone plasmacytomas develop plasma cell myeloma on follow-up. We present a case of a 70-year-old man who presented with fracture and a lytic lesion in the subtrochanteric region of the left femur and was assigned a diagnosis of solitary bone plasmacytoma. He received local curative radiotherapy. However, 4 months later his serum M protein and β2-microglobulin levels increased to 2.31 g/dL and 5.965 mg/L, respectively. He complained of abdominal fullness and constipation. Ultrasound and non-contrast CT imaging revealed multiple retroperitoneal masses. Colonoscopic examination was normal. Biopsy of the a retroperitoneal mass confirmed it to be a plasmacytoma. Repeat hemogram, blood urea, serum creatinine, skeletal survey, and bone marrow examination revealed no abnormalities. This is an unusual presentation of plasma cell myeloma, which manifested as multiple huge extramedullary retroperitoneal masses and arose from a solitary bone plasmacytoma, without related end organ or tissue impairment and bone marrow plasmacytosis. The patient succumbed to his disease 8 months after the appearance of the retroperitoneal masses. This case highlights the importance of close monitoring of patients diagnosed with solitary bone plasmacytoma with increased serum M protein and serum β2-microglobulin levels, so that early therapy can be instituted to prevent conversion to plasma cell myeloma. PMID:25330522
Associations of Mental Health and Physical Function with Colonoscopy-related Pain
Yamada, Eiji; Watanabe, Seitaro; Nakajima, Atsushi
2017-01-01
Objective To clarify the effects of mental health and physical function in association with colonoscopy-related pain. Methods The mental health and physical function were evaluated using the Japanese version of the SF-8 Health Survey questionnaire. Poor physical status was defined as a physical component summary (PCS) <40 and poor mental status as a mental component summary (MCS) <40. Pain was assessed using a visual analogue scale (VAS), with significant pain defined as VAS ≥70 mm and insignificant pain as VAS <70 mm. The background and colonoscopic findings were compared in patients with significant and insignificant pain. Patients This study evaluated consecutive Japanese patients who were positive on fecal occult blood tests and underwent total colonoscopy. Results Of the 100 patients, 23 had significant and 77 had insignificant colonoscopy-related pain. A multiple logistic regression analysis showed that MCS <40 [odds ratio (OR) 6.03; 95% confidence interval (CI) 1.41-25.9, p=0.0156], PCS <40 (OR 5.96; 95% CI 1.45-24.5, p=0.0133), and ≥300 seconds to reach the cecum (OR 4.13; 95% CI 1.16-14.7, p=0.0281) were independent risk factors for colonoscopy-related pain. Conclusion The mental health and physical function are important determinants of colonoscopy-related pain. Evaluating the mental health and physical function of patients prior to colonoscopy may effectively predict the degree of colonoscopy-related pain. PMID:28202858
Optical design of endoscopic shape-tracker using quantum dots embedded in fiber bundles
NASA Astrophysics Data System (ADS)
Eisenstein, Jessica; Gavalis, Robb; Wong, Peter Y.; Cao, Caroline G. L.
2009-08-01
Colonoscopy is the current gold standard for colon cancer screening and diagnosis. However, the near-blind navigation process employed during colonoscopy results in endoscopist disorientation and scope looping, leading to missed detection of tumors, incorrect localization, and pain for the patient. A fiber optic bend sensor, which would fit into the working channel of a colonoscope, is developed to aid navigation through the colon during colonoscopy. The bend sensor is comprised of a bundle of seven fibers doped with quantum dots (QDs). Each fiber within the bundle contains a unique region made up of three zones with differently-colored QDs, spaced 120° apart circumferentially on the fiber. During bending at the QD region, light lost from the fiber's core is coupled into one of the QD zones, inducing fluorescence of the corresponding color whose intensity is proportional to the degree of bending. A complementary metal oxide semiconductor camera is used to obtain an image of the fluorescing end faces of the fiber bundle. The location of the fiber within the bundle, the color of fluorescence, and the fluorescence intensity are used to determine the bundle's bending location, direction, and degree of curvature, respectively. Preliminary results obtained using a single fiber with three QD zones and a seven-fiber bundle containing one active fiber with two QDs (180° apart) demonstrate the feasibility of the concept. Further developments on fiber orientation during bundling and the design of a graphical user interface to communicate bending information are also discussed.
Informative-frame filtering in endoscopy videos
NASA Astrophysics Data System (ADS)
An, Yong Hwan; Hwang, Sae; Oh, JungHwan; Lee, JeongKyu; Tavanapong, Wallapak; de Groen, Piet C.; Wong, Johnny
2005-04-01
Advances in video technology are being incorporated into today"s healthcare practice. For example, colonoscopy is an important screening tool for colorectal cancer. Colonoscopy allows for the inspection of the entire colon and provides the ability to perform a number of therapeutic operations during a single procedure. During a colonoscopic procedure, a tiny video camera at the tip of the endoscope generates a video signal of the internal mucosa of the colon. The video data are displayed on a monitor for real-time analysis by the endoscopist. Other endoscopic procedures include upper gastrointestinal endoscopy, enteroscopy, bronchoscopy, cystoscopy, and laparoscopy. However, a significant number of out-of-focus frames are included in this type of videos since current endoscopes are equipped with a single, wide-angle lens that cannot be focused. The out-of-focus frames do not hold any useful information. To reduce the burdens of the further processes such as computer-aided image processing or human expert"s examinations, these frames need to be removed. We call an out-of-focus frame as non-informative frame and an in-focus frame as informative frame. We propose a new technique to classify the video frames into two classes, informative and non-informative frames using a combination of Discrete Fourier Transform (DFT), Texture Analysis, and K-Means Clustering. The proposed technique can evaluate the frames without any reference image, and does not need any predefined threshold value. Our experimental studies indicate that it achieves over 96% of four different performance metrics (i.e. precision, sensitivity, specificity, and accuracy).
Türk, Hacer Şebnem; Aydoğmuş, Meltem; Ünsal, Oya; Işıl, Canan Tülay; Citgez, Bülent; Oba, Sibel; Açık, Mehmet Eren
2014-12-01
Different drug combinations are used for sedation in colonoscopy procedures. A ketamine-propofol (ketofol) mixture provides effective sedation and has minimal adverse effects. Alfentanil also provides anesthesia for short surgical procedures by incremental injection as an adjunct. However, no study has investigated the use of ketofol compared with an opioid-propofol combination in colonoscopic procedures. A total of 70 patients, ASA physical status I-II, scheduled to undergo elective colonoscopy, were enrolled in this prospective randomized study and allocated to two groups. After premedication, sedation induction was performed with 0.5 mg/kg ketamine +1 mg/kg propofol in Group KP, and 10 mg/kg alfentanil +1 mg/kg propofol in Group AP. Propofol was added when required. Demographic data, colonoscopy duration, recovery time, discharge time, mean arterial pressure (MAP), heart rate (HR), peripheral oxygen saturation, Ramsey Sedation Scale values, colonoscopy patients' satisfaction scores, and complications were recorded. The need for additional propofol doses was significantly higher in Group AP than in Group KP. MAP at minute 1 and 5, Ramsey Sedation Scale at minute 5, and discharge time were significantly higher in Group KP than in Group AP. Additional propofol doses and total propofol dose were significantly lower in Group KP than in Group AP. Ketofol provided better hemodynamic stability and quality of sedation compared with alfentanil-propofol combination in elective colonoscopy, and required fewer additional propofol; however, it prolonged discharge time. Both combinations can safely be used in colonoscopy sedation.
Novel application of simultaneous multi-image display during complex robotic abdominal procedures
2014-01-01
Background The surgical robot offers the potential to integrate multiple views into the surgical console screen, and for the assistant’s monitors to provide real-time views of both fields of operation. This function has the potential to increase patient safety and surgical efficiency during an operation. Herein, we present a novel application of the multi-image display system for simultaneous visualization of endoscopic views during various complex robotic gastrointestinal operations. All operations were performed using the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) with the assistance of Tilepro, multi-input display software, during employment of the intraoperative scopes. Three robotic operations, left hepatectomy with intraoperative common bile duct exploration, low anterior resection, and radical distal subtotal gastrectomy with intracorporeal gastrojejunostomy, were performed by three different surgeons at a tertiary academic medical center. Results The three complex robotic abdominal operations were successfully completed without difficulty or intraoperative complications. The use of the Tilepro to simultaneously visualize the images from the colonoscope, gastroscope, and choledochoscope made it possible to perform additional intraoperative endoscopic procedures without extra monitors or interference with the operations. Conclusion We present a novel use of the multi-input display program on the da Vinci Surgical System to facilitate the performance of intraoperative endoscopies during complex robotic operations. Our study offers another potentially beneficial application of the robotic surgery platform toward integration and simplification of combining additional procedures with complex minimally invasive operations. PMID:24628761
Dave, Maneesh; Johnson, Laura A.; Walk, Seth; Young, Vincent B.; Stidham, Ryan W.; Chaudhary, Meghana N.; FunNell, Jessica; Higgins, Peter D.R.
2014-01-01
Background The study of intestinal microbiota has been revolutionized by the use of molecular methods, including terminal restriction fragment length polymorphism (T-RFLP) analysis. A number of microbiota studies of Crohn’s disease patients have examined samples from stool or from the neoterminal ileum with a standard biopsy forceps, which could be contaminated by colonic bacteria when the forceps passes through the colonoscope channel. Objective To determine whether sheathed biopsy forceps are able to obtain terminal ileal microbiota samples with less colonic bacterial contamination compared to unsheathed (standard) biopsy forceps. Design Prospective randomized single center-study. Patients and Methods We obtained four (paired) biopsy specimens from adjacent locations in the terminal ileum using the sheathed and standard forceps of 27 consecutive subjects undergoing colonoscopy and characterized the microbiota using T-RFLP. We calculated the Bray Curtis similarity index (BCI) between samples (sheathed vs. unsheathed forceps) within patients and tested for significant differences across all patients. Results There was not a significant difference in the microbial diversity of samples obtained using sheathed vs. unsheathed forceps. The difference in microbial diversity between patients was much greater than the variability within patients by proximal vs. distal site or by forceps type. Limitations T-RFLP is based on PCR amplification, so it is not always sensitive to rare bacterial species. Conclusion Standard unsheathed forceps appear to be sufficient for microbiota sample collection from the terminal ileum. PMID:21317176
Colonic diverticulosis is not a risk factor for colonic adenoma.
Hong, Wandong; Dong, Lemei; Zippi, Maddalena; Stock, Simon; Geng, Wujun; Xu, Chunfang; Zhou, Mengtao
2018-01-01
Colonic diverticulosis may represent a risk factor for colonic adenomas by virtue of the fact that evolving data suggest that these 2 conditions may share common risk factors such as Western dietary pattern and physical inactivity. This study aims to investigate the association between colonic diverticulosis and colonic adenomas in mainland China. We conducted a cross-sectional study on patients who underwent colonoscopic examination between October 2013 and December 2014 in a university hospital in mainland China. Age, gender, colonic adenomas, advanced adenomas, and distribution of diverticulosis were recorded during the procedures. Multivariate logistic regression and stratified analysis were used to evaluate the associations between the prevalence of diverticulosis and age, sex, and presence of colonic adenomas and advanced adenomas. A total of 17,456 subjects were enrolled. The prevalence of colonic diverticulosis and adenoma was 2.4% and 13.2%, respectively. With regard to distribution of diverticula, most (365/424, 86.1%) were right-sided. Multiple logistic regression analysis suggested that age and male gender were independent risk factors for adenoma and advanced adenoma. There was no relationship between diverticulosis or location of diverticulosis and presence of adenoma and advanced adenoma adjusting by age and gender. In a stratified analysis according to age and gender, similar results were also noted. There was no statistical relationship between diverticulosis and the risk of adenoma and advanced adenoma. Our results may not be generalized to the Western population due to the fact that left-sided diverticular cases were very small in our study.
Causes Of Lower Gastrointestinal Bleeding On Colonoscopy.
Jehangiri, Attique-Ur-Rehman; Gul, Rahid; Hadayat, Rania; Khan, Adil Naseer; Zabiullah; Khursheed, Liaqat
2017-01-01
Bleeding from anus is usually referred as rectal bleeding but actually rectal bleeding is defined as bleeding from lower colon or rectum, which means bleeding from a place distal to ligament of Treitz. This study was conducted to determine the frequency of different causes of rectal bleeding in patients at Ayub Teaching Hospital, Abbottabad. One hundred and seventy-five patients with evidence of rectal bleed, without gender discrimination were selected by non-probability convenient sampling from the out-patient department and general medical wards. Patients with suspected upper GI source of bleeding; acute infectious bloody diarrhoea and any coagulopathy were excluded from the study. All patients were subjected to fibre optic colonoscopy after preparation of the gut and findings were recorded. Where necessary, biopsy samples were also taken. Diagnosis was based on colonoscopic findings. A total of 175 patients (92 males and 83 females) with mean age 35.81±9.18 years were part of the study. Colonoscopy showed abnormal findings in 150 (85.7%) patients. The commonest diagnosis was haemorrhoids, which was found in 39 (22.3%) patients. It was followed by inflammatory bowel disease (IBD) in 30 (17.1%) patients, solitary rectal ulcer in 13 (7.4%) patients and polyps in 25 (14.3%) patients. Other less frequent findings were non-specific inflammation and fungating growths in rectum. Haemorrhoids was the leading cause of bleeding per rectum in this study, followed by evidence of IBD while infrequent findings of polyps and diverticuli indicate that these are uncommon in this region.
Asayama, Naoki; Nagata, Shinji; Shigita, Kenjiro; Aoyama, Taiki; Fukumoto, Akira; Mukai, Shinichi
2018-03-01
Benign colonic anastomotic stenosis sometimes occurs after surgical resection and usually requires surgical or endoscopic dilation. Limited data are available on the effectiveness and safety of the endoscopic radial incision and cutting (RIC) method at sites other than the esophagus. The aim of this retrospective study was to investigate the effectiveness and safety of RIC dilation for severe benign anastomotic colonic stenosis. Subjects were 3 men (median age 72 years, range 65 - 76 years) who developed severe benign anastomotic stenosis after surgical resection for colorectal carcinoma and were subsequently treated by RIC dilation at Hiroshima City Asa Citizens Hospital between May 2014 and December 2016. Severe anastomotic stenosis was defined as a narrowed anastomosis through which a standard colonoscope could not be passed. The median interval from surgery to RIC was 21 months (range 9 - 29 months). RIC was successful in all 3 patients and reduced the severity of dyschezia postoperatively; 2 patients experienced improvement after a single RIC session and the other after 6 RIC sessions. No treatment-related adverse events or re-stenosis requiring repeat dilation was noted during a median follow-up of 27 months (range 8 - 37 months). Our findings indicate that the RIC technique can be applied safely and effectively to various sites in the colon, avoiding the need for reoperation.
Review of emerging surgical robotic technology.
Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry
2018-04-01
The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.
High self-efficacy predicts adherence to surveillance colonoscopy in inflammatory bowel disease.
Friedman, Sonia; Cheifetz, Adam S; Farraye, Francis A; Banks, Peter A; Makrauer, Frederick L; Burakoff, Robert; Farmer, Barbara; Torgersen, Leanne N; Wahl, Kelly E
2014-09-01
Patients with extensive ulcerative colitis or Crohn's disease of the colon have an increased risk of colon cancer and require colonoscopic surveillance. In this study, we assessed individual self-efficacy (SE) to estimate the probability of adherence to surveillance colonoscopies. Three hundred seventy-eight patients with ulcerative colitis or Crohn's disease of the colon for at least 7 years and with at least one third of the colon involved participated in this cross-sectional questionnaire study performed at 3 tertiary referral inflammatory bowel disease clinics. Medical charts were abstracted for demographic and clinical variables. The questionnaire contained a group of items assessing SE for undergoing colonoscopy. We validated our 20-question SE scale and used 8 of the items that highlighted scheduling, preparation, and postprocedure recovery, to develop 2 shorter SE scales. All 3 scales were reliable with Cronbach's α ranging from 0.845 to 0.905 and correlated with chart-documented adherence to surveillance colonoscopy (P < 0.001). We then developed logistic regression models to predict adherence to surveillance colonoscopy using each scale separately along with other key variables (i.e., disease location, knowledge of correct adherence intervals, and information sources of patients consulted regarding Crohn's disease and ulcerative colitis) and demonstrated model accuracy up to 74%. SE, as measured by our validated scales, correlates with chart-adherence to surveillance colonoscopy. Our adherence model, which includes SE, predicts adherence with 74% certainty. An 8-item validated clinical questionnaire can be administered to assess whether patients in this population may require further intervention for adherence.
Severe and Rapid Progression in Very Early-Onset Chronic Granulomatous Disease-Associated Colitis.
Kawai, Toshinao; Arai, Katsuhiro; Harayama, Shizuko; Nakazawa, Yumiko; Goto, Fumihiro; Maekawa, Takanobu; Tamura, Eiichiro; Uchiyama, Toru; Onodera, Masafumi
2015-08-01
Chronic granulomatous disease (CGD) is a primary immunodeficiency disease that leads to recurrent infection and hyper-inflammation, occasionally represented by CGD-associated colitis (CGD colitis). Although clinical symptoms of CGD colitis mimic those of ulcerative colitis (UC), there is no reliable standard measurement of disease activity or standard therapeutic strategy for CGD colitis. Here, we examined the clinical manifestation of CGD colitis based on severity using a noninvasive measure of disease activity, the Pediatric Ulcerative Colitis Activity Index (PUCAI), which has been validated and widely used for pediatric UC. Sixteen of 35 CGD patients, who were diagnosed with CGD colitis based on colonoscopic and histological findings, were examined using the PUCAI. Both the PUCAI and the physician global assessment (PGA) tool were retrospectively scored by reviewing medical records. Disease activity defined by PUCAI was correlated with PGA, and increased at diagnosis of CGD colitis, especially in patients who were younger than 6 years of age (very early-onset CGD colitis: VEO-CGD colitis) when diagnosed with CGD colitis. All severe patients had a more progressive form of VEO-CGD colitis. Unlike mild and moderate patients, severe patients required multidrug therapy of corticosteroids and immunomodulator/immunosuppressants, and some were eventually treated with hematopoietic stem cell transplantation. Although the validation of PUCAI in CGD colitis should be considered for future use, our results indicate that noninvasive measures could be effective to measure disease activity and help to determine suitable treatment for CGD colitis. In patients with VEO-CGD colitis, multidrug therapy would need to be considered at an early stage on the basis of disease activity.
One year in review 2016: Behçet's syndrome.
Hatemi, Gulen; Seyahi, Emire; Fresko, Izzet; Talarico, Rosaria; Hamuryudan, Vedat
2016-01-01
Several articles highlighting the epidemiology, pathogenesis, clinical features, treatment modalities and disease assessment of Behçet's syndrome (BS) have been published during the last year. Clinical and radiological features of lower extremity deep vein thrombosis due to BS can be quite different than those found in thrombosis due to other causes; additionally, frequency of post-thrombotic syndrome is significantly increased in BS. Some clinical and colonoscopic features are useful in differentiating BS from Crohn's disease. Barkhof criteria may be helpful in differentiating neurologic involvement due to BS from multiple sclerosis. Anatomical localization of papulopustular lesions but not histology has been found to be helpful in differentiating papulopustular lesions of BS from those found in acne vulgaris. Several studies looked at the ovarian reserve with contradicting results. A population-based cohort study found higher risk of hematological malignancies only among female BS patients living in Taiwan. The role of genetic factors and environment is discussed and both autoimmune and autoinflammatory features are underlined in the pathogenesis of BS. New data on the epistatic interactions between ERAP and HLA B51 is available and information on the microbiome have started to appear. New uncontrolled data suggest beneficial effects of anti-TNFs for refractory extra-ocular complications of BS such as pulmonary artery, gastrointestinal and central nervous system involvement. Uncontrolled studies suggest promising results with interleukin-1 inhibition but gevokizumab, a humanised anti IL-1β antibody, failed to meet the primary endpoint of time to first ocular exacerbation in a phase III trial. The debate on anticoagulation continues with new observational data.
Moriichi, Kentaro; Fujiya, Mikihiro; Sato, Ryu; Watari, Jiro; Nomura, Yoshiki; Nata, Toshie; Ueno, Nobuhiro; Maeda, Shigeaki; Kashima, Shin; Itabashi, Kentaro; Ishikawa, Chisato; Inaba, Yuhei; Ito, Takahiro; Okamoto, Kotaro; Tanabe, Hiroki; Mizukami, Yusuke; Saitoh, Yusuke; Kohgo, Yutaka
2012-06-22
Some patients under close colonoscopic surveillance still develop colorectal cancer, thus suggesting the overlook of colorectal adenoma by endoscopists. AFI detects colorectal adenoma as a clear magenta, therefore the efficacy of AFI is expected to improve the detection ability of colorectal adenoma. The aim of this study is to determine the efficacy of AFI in detecting colorectal adenoma. This study enrolled 88 patients who underwent colonoscopy at Asahikawa Medical University and Kushiro Medical Association Hospital. A randomly selected colonoscopist first observed the sigmoid colon and rectum with conventional high resolution endosopy (HRE). Then the colonoscopist changed the mode to AFI and handed to the scope to another colonoscopist who knew no information about the HRE. Then the second colonoscopist observed the sigmoid colon and rectum. Each colonoscopist separately recorded the findings. The detection rate, miss rate and procedural time were assessed in prospective manner. The detection rate of flat and depressed adenoma, but not elevated adenoma, by AFI is significantly higher than that by HRE. In less-experienced endoscopists, AFI dramatically increased the detection rate (30.3%) and reduced miss rate (0%) of colorectal adenoma in comparison to those of HRE (7.7%, 50.0%), but not for experienced endoscopists. The procedural time of HRE was significantly shorter than that of AFI. AFI increased the detection rate and reduced the miss rate of flat and depressed adenomas. These advantages of AFI were limited to less-experienced endoscopists because experienced endoscopists exhibited a substantially high detection rate for colorectal adenoma with HRE.
2012-01-01
Background Some patients under close colonoscopic surveillance still develop colorectal cancer, thus suggesting the overlook of colorectal adenoma by endoscopists. AFI detects colorectal adenoma as a clear magenta, therefore the efficacy of AFI is expected to improve the detection ability of colorectal adenoma. The aim of this study is to determine the efficacy of AFI in detecting colorectal adenoma. Methods This study enrolled 88 patients who underwent colonoscopy at Asahikawa Medical University and Kushiro Medical Association Hospital. A randomly selected colonoscopist first observed the sigmoid colon and rectum with conventional high resolution endosopy (HRE). Then the colonoscopist changed the mode to AFI and handed to the scope to another colonoscopist who knew no information about the HRE. Then the second colonoscopist observed the sigmoid colon and rectum. Each colonoscopist separately recorded the findings. The detection rate, miss rate and procedural time were assessed in prospective manner. Results The detection rate of flat and depressed adenoma, but not elevated adenoma, by AFI is significantly higher than that by HRE. In less-experienced endoscopists, AFI dramatically increased the detection rate (30.3%) and reduced miss rate (0%) of colorectal adenoma in comparison to those of HRE (7.7%, 50.0%), but not for experienced endoscopists. The procedural time of HRE was significantly shorter than that of AFI. Conclusions AFI increased the detection rate and reduced the miss rate of flat and depressed adenomas. These advantages of AFI were limited to less-experienced endoscopists because experienced endoscopists exhibited a substantially high detection rate for colorectal adenoma with HRE. PMID:22726319
Kamba, Alan; Lee, In-Ah; Mizoguchi, Emiko
2013-01-01
Inflammatory bowel disease (IBD) is a group of inflammatory disorders in the small and large intestines. Several studies have proved that persistent and disregulated host/microbial interactions are required for the development of IBD. It is well known that chronic IBD is strongly associated with an increased risk of developing colorectal cancer by 0.5–1% annually, 8–10 years after the initial diagnosis. To detect the tiny dysplasia or early stage of cancer in chronic IBD patients, a tremendous amount of effort is currently directed for improving colonoscopic technology and noninvasive serological marker development. However, there is only a limited amount of data available to understand the exact mechanism of how long term chronic colitis is connected to the development of colorectal tumors. Recently, our group has identified that significantly increased expression of chitinase 3-like 1 (CHI3L1) molecule in non-dysplastic mucosa from patients with IBD and remote dysplasia/cancer, compared to patients with IBD without dysplasia or healthy controls. CHI3L1 seems to contribute to the proliferation, migration, and neoplastic progression of colonic epithelial cells (CECs) under inflammatory conditions. Furthermore, the CHI3L1-mediated intracellular signaling cascade is likely to interact with TLR4 signaling in CECs. In this review article, we have concisely summarized the cellular and molecular mechanisms underlining the development of IBD and colitis-associated cancer, with particular focus on the CHI3L1-and TLR4-signaling pathways in CECs. PMID:23170831
Han, Min Seok; Lee, Hyun Jung; Park, Soo Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Won Ho; Kim, Tae Il
2017-08-01
Existing studies suggest that metformin lowers the risk and mortality of colorectal cancer. However, the effect of metformin on the suppression and prevention of colorectal adenomas is not clear. The aim of this study was to evaluate the effect of metformin on the recurrence of colorectal adenoma in diabetic patients with previous colorectal adenoma. Among 423 diabetic patients who underwent surveillance colonoscopy after resection of colorectal adenoma between 2005 and 2011, 257 patients were retrospectively reviewed. The patients were divided into two groups: one group comprising 106 patients who took metformin and another group comprising 151 patients who did not take metformin. The clinical characteristics, colorectal adenoma recurrence, and valuable factors for adenoma recurrence were analyzed. At surveillance colonoscopy after colonoscopic polypectomy for adenoma, 38 patients (35.8%) exhibited colorectal adenoma among 106 patients who took metformin, compared with 85 patients (56.3%) with colorectal adenoma among 151 patients who did not take metformin (odds ratio 0.434, 95% confidence interval 0.260-0.723, P = 0.001). Multivariate Cox analysis showed that metformin was associated with decreased recurrence of colorectal adenoma (hazard ratio 0.572, 95% confidence interval 0.385-0.852, P = 0.006) in diabetic patients with previous colorectal adenoma. The cumulative probability of colorectal adenoma recurrence was significantly lower in the metformin group than in the non-metformin group (P = 0.001). Metformin use in diabetic patients with previous colorectal adenoma is associated with a lower risk of colorectal adenoma recurrence.
NASA Astrophysics Data System (ADS)
Kim, Young L.; Pradhan, Prabhakar; Turzhitsky, Vladimir M.; Subramanian, Hariharan; Liu, Yang; Wali, Ramesh K.; Roy, Hemant K.; Backman, Vadim
2007-02-01
The phenomenon of enhanced backscattering (EBS) of light, also known as coherent backscattering (CBS) of light, is a spectacular manifestation of self-interference effects in elastic light scattering, which gives rise to an enhanced scattered intensity in the backward direction. Although EBS has been the object of intensive investigation in non-biological media over the last two decades, there have been only a few attempts to explore EBS for tissue characterization and diagnosis. We have recently made progress in the EBS measurements of biological tissue by taking advantage of lowcoherence (or partially coherent) illumination, which is referred to as low-coherence EBS (LEBS) of light. LEBS possess novel and intriguing properties such as speckle reduction, self-averaging effect, broadening of the EBS width, depth-selectivity, double scattering, and circular polarization memory effect. After we review the current state of research on LEBS, we discuss how these characteristics apply for early cancer detection, especially in colorectal cancer (CRC), which is the second leading cause of cancer mortality in the United States. Although colonoscopy remains the gold standard for CRC screening, resource constraints and potential complications make it impractical to perform colonoscopy on the entire population at risk (age > 50). Thus, identifying patients who are most likely to benefit from colonoscopy is of paramount importance. We demonstrate that LEBS measurements in easily accessible colonoscopically normal mucosa (e.g., in the rectum of the colon) can be used for predicting the risk of CRC, and thus LEBS has the potential to serve as accurate markers of the risk of neoplasia elsewhere in the colon.
Pacheco, Rodrigo Goulart; Esposito, Christiano Costa; Müller, Lucas CM; Castelo-Branco, Morgana TL; Quintella, Leonardo Pereira; Chagas, Vera Lucia A; de Souza, Heitor Siffert P; Schanaider, Alberto
2012-01-01
AIM: To investigate whether butyrate or glutamine enemas could diminish inflammation in experimental diversion colitis. METHODS: Wistar specific pathogen-free rats were submitted to a Hartmann’s end colostomy and treated with enemas containing glutamine, butyrate, or saline. Enemas were administered twice a week in the excluded segment of the colon from 4 to 12 wk after the surgical procedure. Follow-up colonoscopy was performed every 4 wk for 12 wk. The effect of treatment was evaluated using video-endoscopic and histologic scores and measuring interleukin-1β, tumor necrosis factor-alpha, and transforming growth factor beta production in organ cultures by enzyme linked immunosorbent assay. RESULTS: Colonoscopies of the diverted segment showed mucosa with hyperemia, increased number of vessels, bleeding and mucus discharge. Treatment with either glutamine or butyrate induced significant reductions in both colonoscopic (P < 0.02) and histological scores (P < 0.01) and restored the densities of collagen fibers in tissue (P = 0.015; P = 0.001), the number of goblet cells (P = 0.021; P = 0.029), and the rate of apoptosis within the epithelium (P = 0.043; P = 0.011) to normal values. The high levels of cytokines in colon explants from rats with diversion colitis significantly decreased to normal values after treatment with butyrate or glutamine. CONCLUSION: The improvement of experimental diversion colitis following glutamine or butyrate enemas highlights the importance of specific luminal nutrients in the homeostasis of the colonic mucosa and supports their utilization for the treatment of human diversion colitis. PMID:22969190
Vavricka, S R; Tutuian, R; Imhof, A; Wildi, S; Gubler, C; Fruehauf, H; Ruef, C; Schoepfer, A M; Fried, M
2010-09-01
Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination. This was a prospective single-blinded trial involving 50 patients who were undergoing elective nontherapeutic colonoscopy. During colonoscopy, endoscopists removed the biopsy forceps first without and then with suctioning following contact with the sigmoid mucosa. A total of 50 L of air was collected continuously for 30 seconds at 30-cm distance from the biopsy channel valve of the colonoscope, with time starting at forceps removal. Airborne bacteria were collected by an impactor air sampler (MAS-100). Standard Petri dishes with CNA blood agar were used to culture Gram-positive bacteria. Main outcome measure was the bacterial load in endoscopy room air. At the beginning and end of the daily colonoscopy program, the median (and interquartile [IQR] range) bioaerosol burden was 4 colony forming units (CFU)/m (3) (IQR 3 - 6) and 16 CFU/m (3) (IQR 13 - 18), respectively. Air suctioning during removal of the biopsy forceps reduced the bioaerosol burden from a median of 14 CFU/m (3) (IQR 11 - 29) to a median of 7 CFU/m (3) (IQR 4 - 16) ( P = 0.0001). Predominantly enterococci were identified on the agar plates. The bacterial aerosol burden during handling of biopsy forceps can be reduced by applying air suction while removing the forceps. This simple method may reduce transmission of infectious agents during gastrointestinal endoscopies. Copyright Georg Thieme Verlag KG Stuttgart . New York.
Multiple primary tumors: Colorectal carcinoma and non-Hodgkin's lymphoma.
Pantoja Pachajoa, Diana A; Bruno, Marco Antonio; Alvarez, Fernando A; Viscido, Germán; Mandojana, Facundo; Doniquian, Alejandro
2018-05-30
Colorectal cancer (CRC) is the third most commonly diagnosed cancer, whereas lymphoma is the sixth leading cause of cancer death, 90% of which corresponds to non-Hodgkin's lymphoma (NHL). The association of these two primary tumors, a solid tumor with an hematological malignancy, is very uncommon. We report the case of a 47-year-old man who presented with abdominal pain, a right upper quadrant mass and 12 kg of weight loss in 9 months. The computed tomography (CT) showed a large intra-abdominal mass and a wall thickening at the rectosigmoid junction. A colonoscopic biopsy confirmed a colorectal adenocarcinoma and a laparoscopic biopsy of the intraabdominal mass confirmed a diffuse large B-cell NHL. After multidisciplinary discussion it was decided to treat first the NHL with 3 cycles of R-CHOP chemotherapy (cyclophosphamide, doxorubicin, vincristine and prednisone). The patient experienced a good response with a 70% decrease in the intraabdominal mass and a negative PET/CT. Four months after diagnosis an anterior rectal resection was performed. The patient recovered uneventfully and was discharged 5 days after surgery. The patient finally died 20 months after surgery due to disease progression. The association of CRC and NHL is an extremely rare scenario that represents a great multidisciplinary challenge with respect to treatment due to the scarce literature found on this topic. When CRC and NHL are present, all the different disease patterns must be considered in a multidisciplinary and patient-oriented fashion, in order to decide the best therapeutic strategy for each individual. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Staley, Christopher; Vaughn, Byron P; Graiziger, Carolyn T; Singroy, Stephanie; Hamilton, Matthew J; Yao, Dan; Chen, Chi; Khoruts, Alexander; Sadowsky, Michael J
2017-05-04
Fecal microbiota transplantation (FMT) is a highly effective treatment of recurrent and recalcitrant Clostridium difficile infection (rCDI). In a recent study oral-delivery of encapsulated, freeze-dried donor material, resulted in comparable rates of cure to colonoscopic approaches. Here we characterize shifts in the fecal bacterial community structure of patients treated for rCDI using encapsulated donor material. Prior to FMT, patient fecal samples showed declines in diversity and abundance of Firmicutes and Bacteroidetes, with concurrent increases in members of the Proteobacteria, specifically Enterobacteriaceae. Moreover, patients who experienced recurrence of CDI within the 2-month clinical follow-up had greater abundances of Enterobacteriaceae and did not show resolution of dysbioses. Despite resolution of rCDI following oral-administration of encapsulated fecal microbiota, community composition was slow to return to a normal donor-like assemblage. Post-FMT taxa within the Firmicutes showed rapid increases in relative abundance and did not vary significantly over time. Conversely, Bacteroidetes taxa only showed significant increases in abundance after one month post-FMT, corresponding to significant increases in the community attributable to the donors. Changes in the associations among dominant OTUs were observed at days, weeks, and months post-FMT, suggesting shifts in community dynamics may be related to the timing of increases in abundance of specific taxa. Administration of encapsulated, freeze-dried, fecal microbiota to rCDI patients resulted in restoration of bacterial diversity and resolution of dysbiosis. However, shifts in the fecal microbiome were incremental rather than immediate, and may be driven by changes in community dynamics reflecting changes in the host environment.
British Society of Gastroenterology position statement on serrated polyps in the colon and rectum
East, James E; Atkin, Wendy S; Bateman, Adrian C; Clark, Susan K; Dolwani, Sunil; Ket, Shara N; Leedham, Simon J; Phull, Perminder S; Rutter, Matt D; Shepherd, Neil A; Tomlinson, Ian; Rees, Colin J
2017-01-01
Serrated polyps have been recognised in the last decade as important premalignant lesions accounting for between 15% and 30% of colorectal cancers. There is therefore a clinical need for guidance on how to manage these lesions; however, the evidence base is limited. A working group was commission by the British Society of Gastroenterology (BSG) Endoscopy section to review the available evidence and develop a position statement to provide clinical guidance until the evidence becomes available to support a formal guideline. The scope of the position statement was wide-ranging and included: evidence that serrated lesions have premalignant potential; detection and resection of serrated lesions; surveillance strategies after detection of serrated lesions; special situations—serrated polyposis syndrome (including surgery) and serrated lesions in colitis; education, audit and benchmarks and research questions. Statements on these issues were proposed where the evidence was deemed sufficient, and re-evaluated modified via a Delphi process until >80% agreement was reached. The Grading of Recommendations, Assessment, Development and Evaluations (GRADE) tool was used to assess the strength of evidence and strength of recommendation for finalised statements. Key recommendation: we suggest that until further evidence on the efficacy or otherwise of surveillance are published, patients with sessile serrated lesions (SSLs) that appear associated with a higher risk of future neoplasia or colorectal cancer (SSLs ≥10 mm or serrated lesions harbouring dysplasia including traditional serrated adenomas) should be offered a one-off colonoscopic surveillance examination at 3 years (weak recommendation, low quality evidence, 90% agreement). PMID:28450390
Diagnostic accuracy of pit pattern and vascular pattern analyses in colorectal lesions.
Wada, Yoshiki; Kashida, Hiroshi; Kudo, Shin-ei; Misawa, Masashi; Ikehara, Nobunao; Hamatani, Shigeharu
2010-07-01
The aim of this prospective study is to compare the usefulness of magnifying narrow band imaging (NBI) and magnifying chromoendoscopy in the diagnosis of colorectal lesions. The subjects were 1185 patients who underwent a complete colonoscopic examination and endoscopic or surgical treatment, from January 2006 to February 2008. A total of 1473 lesions were evaluated (53 hyperplastic polyps, 1317 adenomas, 103 submucosally invasive cancers). The digital images with NBI or chromoendoscopy were recorded and diagnosed independently from each other by two endoscopists who were blinded to the final pathological diagnosis. We could differentiate between neoplastic and non-neoplastic lesions with sensitivity of 88.9%, specificity of 98.5% and accuracy of 98.2% according to the vascular pattern. By recognizing an irregular or sparse pattern with NBI, massively invasive submucosal cancer could be diagnosed with the sensitivity and specificity of 94.9% and 76.0%. Using chromoendoscopy, we could differentiate between neoplastic and non-neoplastic lesions with sensitivity of 86.8% and specificity of 99.2%. We were able to differentiate between massively invasive cancers and slightly invasive cancers using the pit patterns with sensitivity of 89.7% and specificity of 88.0%. The specificity was superior to that of NBI colonoscopy. Both NBI and chromoendoscopy can be useful for distinguishing between neoplastic and non-neoplastic lesions. In the diagnosis of submucosal cancer, pit pattern diagnosis was slightly superior to vascular pattern diagnosis. It is desirable to perform chromoendoscopy in addition to NBI for distinguishing between slightly and massively invasive submucosal cancer lesions and determining the treatment.
Zaidman, Jeffrey S; Frederick, William G; Furth, Emma E; Su, Chinyu G; Ginsberg, Gregory G
2006-10-01
The multibite biopsy forceps is intended for consecutive acquisition of numerous tissue specimens with a single pass. The Pelican multibite forceps is equipped with a sleeve for tissue retention that allows up to 6 specimens to be obtained with each pass of the device through the accessory channel. Reducing the need for device exchange could decrease the total procedure time for colon cancer surveillance in patients with longstanding inflammatory bowel disease (IBD). The aim of this study was to evaluate a new multibite biopsy forceps in comparison with a standard double-bite forceps. Prospective randomized animal model trial. Multicenter university and community hospitals. By using a live porcine model, multiple colonoscopic biopsy specimens were obtained with both the Pelican multibite forceps and the Radial Jaw 3 (RJ3) double-bite forceps to mimic colorectal cancer surveillance in patients with IBD. Six biopsy specimens were obtained with each of 6 passes when using the Pelican forceps, and 2 biopsy specimens were obtained with each of 18 passes when using the RJ3 forceps. All trials were timed. Two independent pathologists blinded to the forceps used evaluated the specimens. Tissue acquisition when using the Pelican multibite forceps was significantly faster than with a standard double-bite forceps. The devices compared equivalently for specimen retention and quality. The operator could not be blinded to the devices used. This study uses an animal model to extrapolate how the devices might perform in human use. These findings support the evaluation of the Pelican forceps for colon cancer surveillance in patients with longstanding IBD.
Use of a nitinol stent to palliate a colorectal neoplastic obstruction in a dog
Culp, William T. N.; MacPhail, Catriona M.; Perry, James A.; Jensen, Tracey D.
2015-01-01
Case Description A 12-year-old castrated male Labrador Retriever was evaluated for clinical signs associated with colorectal obstruction. Clinical Findings The dog had a 2-week history of tenesmus and hematochezia. On rectal examination, an annular colorectal mass was palpable extending orad into the pelvic canal. The original diagnosis of the colorectal mass was a mucosal adenoma. The dog was maintained on a low-residue diet and fecal softeners for a period of 13 months after initial diagnosis. At that time, medical management was no longer effective. Treatment and Outcome Placement of a colonic stent was chosen to palliate the clinical signs associated with colorectal obstruction. By use of fluoroscopic and colonoscopic guidance, a nitinol stent was placed intraluminally to open the obstructed region. Placement of the stent resulted in improvement of clinical signs, although tenesmus and obstipation occurred periodically after stent placement. At 212 days after stent placement, the patient had extensive improvement in clinical signs with minimal complications; however, clinical signs became severe at 238 days after stent placement, and the dog was euthanized. Histologic evaluation of the rectal tumor from samples obtained during necropsy revealed that the tumor had undergone malignant transformation to a carcinoma in situ. Clinical Relevance A stent was successfully placed in the colon and rectum to relieve obstruction associated with a tumor originally diagnosed as a benign neoplasm. Placement of colorectal stents may be an option for the palliation of colorectal obstruction secondary to neoplastic disease; however, clinical signs may persist, and continuation of medical management may be necessary. PMID:21756178
Min, Myo; Chua, Benjamin; Guttner, Yvonne; Abraham, Ned; Aherne, Noel J; Hoffmann, Matthew; McKay, Michael J; Shakespeare, Thomas P
2014-02-01
Pelvic radiation disease (PRD) also widely known as "radiation proctopathy" is a well recognised late side-effect following conventional prostate radiotherapy. However, endoscopic evaluation and/or specialist referral for new or persistent post-prostate radiotherapy bowel symptoms is not routine and serious diagnoses may potentially be missed. Here we report a policy of endoscopic evaluation of bowel symptoms persisting >90 days post radiotherapy for prostate cancer. A consecutive series of 102 patients who had radical prostate intensity-modulated radiotherapy (IMRT)/image-guided radiotherapy (IGRT) and who had new or ongoing bowel symptoms or positive faecal occult blood tests (FOBT) on follow up visits more than three months after treatment, were referred for endoscopic examination. All but one (99%) had full colonoscopic investigation. Endoscopic findings included gastric/colonic/rectal polyps (56%), diverticular disease (49%), haemorrhoids (38%), radiation proctopathy (29%), gastritis/oesophagitis (8%) and rarer diagnoses, including bowel cancer which was found in 3%. Only four patients (4%) had radiation proctopathy without associated pathology and 65 patients (63%) had more than one diagnosis. If flexible sigmoidoscopy alone were used, 36.6% of patients and 46.6% patients with polyp(s) would have had their diagnoses missed. Our study has shown that bowel symptoms following prostate IMRT/IGRT are due to numerous diagnoses other than PRD, including malignancy. Routine referral pathways should be developed for endoscopic evaluation/specialist review for patients with new or persistent bowel symptoms (or positive FOBT) following prostate radiotherapy. This recommendation should be considered for incorporation into national guidelines. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Zigmond, Ehud; Varol, Chen; Kaplan, Michail; Shapira, Oz; Melzer, Ehud
2014-08-01
The aim of this study was to demonstrate the effect of low-level light therapy (LLLT) in an acute colitis model in mice. Low-level light therapy (LLLT) has been shown to be an effective treatment for various inflammatory processes such as oral mucositis and diabetic foot ulcers. Colitis was induced by dextran sodium sulfate (DSS) in mice in four blinded controlled studies (validation of model, efficacy study, and two studies for evaluation of optimal dose). LLLT was applied to the colon utilizing a small diameter endoscope with an LED-based light source in several wavelengths (440, 660, and 850 nm at 1 J/cm(2)) and then 850 nm at several doses (1, 0.5, 0.25, and 0.1 J/cm(2)). LLLT was initiated 1 day prior to induction of colitis and went on for the 6 day induction period as well as for the following 3-10 days. Dose was controlled by changing exposure time. Disease activity was scored endoscopically and by histopathological assessment. Statistically significant improvement in disease severity was observed in the treatment groups compared with the control groups. The three wavelengths used demonstrated efficacy, and a clear dose-response curve was observed for one of the wavelengths (850 nm). On day 11, colonoscopic scoring in the sham-treated mice increased from 7.9±1.3 to 12.2±2.2, while activity in all treated groups remained stable. Photobiostimulation with LLLT has a significant positive effect on disease progression in mice with DSS colitis.
Castillo, Ofelia; Barreda, Carlos; Recavarren, Sixto; Barriga, José A; Salazar M, Fernando; Yriberry, Simón; Barriga, Eduardo; Salazar C, Fernando
2013-01-01
To describe the clinical and endoscopic caracteristics of a population that has only serrated polyps of colon (mainly sessile serrated adenomas) in a private clinic in Lima, Perú, from 2009-2011. Retrospective study conducted at the endoscopy center of Clinic Ricardo Palma, Lima, Peru. Olympus colonoscope was used with high definition, including NBI (narrow band imaging) and electronic magnification. Patients had pathologic diagnosis of “polyps and / or colorectal serrated adenomas†and excluded those with synchronous tubular or villous adenomas. Images were evaluated by two endoscopists and then by a third gastroenterologist. We found 201 serrated polyps in 108 patients. Women were 60.2% and overweight predominated. Eighty (74.1%) had only one serrated adenoma and 23 (21.3%) with at least one synchronous hyperplastic polyp. The average size of sessile serrated adenomas was 5.12 mm (± 3.87 DS) and the flat type was 91 (58.7%). There were significant differences in the diameter of sessile serrated adenomas between the distal and proximal colon (4.47 mm ± 2.23 vs. 6.90 mm ± 6.25; p<0.000). The common features of sessile serrated adenomas were: White (31/36, 86.1%), smooth (28/36, 77.8%) and regular margins (26/36, 72.2%). There was a relationship between vascular pattern according NBI and serrated polyp histology (p=0.024). The endoscopic features of sessile serrated adenomas can evade detection to white light. NBI is a useful tool to define some features of these lesions.
Bapaye, Amol; Wagholikar, Gajanan; Jog, Sameer; Kothurkar, Aditi; Purandare, Shefali; Dubale, Nachiket; Pujari, Rajendra; Mahadik, Mahesh; Vyas, Viral; Bapaye, Jay
2016-09-01
Hirschsprung's disease (HD) is a congenital disorder characterized by the absence of intrinsic ganglion cells in submucosal and myenteric plexuses of the hindgut; and presents with constipation, intestinal obstruction and/or megacolon. HD commonly involves the rectosigmoid region (short segment HD), although shorter and longer variants of the disease are described. Standard treatment involves pull-through surgery for short segment HD or posterior anorectal myotomy in selected ultrashort segment candidates. Third space endoscopy has evolved during the past few years. Per oral endoscopic myotomy and per oral pyloromyotomy are described for treatment of achalasia cardia and refractory gastroparesis, respectively. Using the same philosophy of muscle/sphincter disruption for spastic bowel segments, per rectal endoscopic myotomy could be considered as a treatment option for short segment HD. A 24-year-old male patient presented with refractory constipation since childhood, and habituated to high-dose laxative combinations. Diagnosis was confirmed as adult short segment HD by barium enema, colonoscopic deep suction mucosal biopsies and anorectal manometry. Histopathology confirmed aganglionosis in the distal 15 cm. By implementing principles of third space endoscopy, per rectal endoscopic myotomy 20 cm in length was successfully carried out. At 24-week follow up, the patient reported significant relief of constipation and associated symptoms. Sigmoidoscopy, anorectal manometry and barium enema confirm improved rectal distensibility and reduced rectal pressures. The present case report describes the first human experience of per rectal endoscopic myotomy for successful treatment of adult short segment HD. © 2016 Japan Gastroenterological Endoscopy Society.
Heyman, Melvin B.; Kierkus, Jaroslaw; Spénard, Jean; Shbaklo, Hadia; Giguere, Monique
2011-01-01
Background Treatment of ulcerative proctitis has not been well studied in pediatric populations. We conducted an open-label trial to evaluate the clinical efficacy of a mesalamine suppository (500 mg) to treat pediatric patients with mild to moderate ulcerative proctitis. Methods Pediatric patients (5–17 years of age) with ulcerative proctitis were enrolled for baseline evaluations, including a flexible sigmoidoscopic (or colonoscopic) assessment with biopsies performed at study entry. Eligible patients were started on mesalamine suppositories (500 mg) at bedtime. Two follow-up visits were scheduled after 3 and 6 weeks of treatment. The dose could be increased to 500 mg twice daily at the week 3 follow-up visit if deemed appropriate by the investigator based on the Disease Activity Index (DAI) assessment. The primary outcome measure was a DAI derived from a composite score of stool frequency, urgency of defecation, rectal bleeding, and general well-being. Results Forty-nine patients were included in the intent-to-treat analysis. The mean DAI value decreased from 5.5 at baseline to 1.6 and 1.5 at weeks 3 and 6, respectively (P < 0.0001). Only 4 patients had their dose increased to 500 mg twice daily at week 3. Forty-one patients experienced at least one adverse event, most of which were deemed mild and unrelated to study therapy. The most common treatment-emergent adverse events were gastrointestinal (n = 30, 61.2%). Conclusions This study showed that a daily bedtime dose of a 500 mg mesalamine suppository is safe and efficacious in children with ulcerative proctitis. PMID:20848454
Sohn, Won; Lee, Oh Young; Lee, Sang Pyo; Lee, Kang Nyeong; Jun, Dae Won; Lee, Hang Lak; Yoon, Byung Chul; Choi, Ho Soon; Sim, Jongmin; Jang, Ki-Seok
2014-01-01
Recent studies have shown that mast cells play an important role in irritable bowel syndrome (IBS). We investigated the relationship between mast cells and the gut hormones substance P and vasoactive intestinal peptide (VIP) in irritable bowel syndrome with diarrhea (IBS-D). Colonoscopic biopsies were performed on the rectal mucosa of 43 subjects (IBS-D patients: 22, healthy volunteers: 21) diagnosed according to the Rome III criteria. Mast cells, and substance P & VIP were evaluated by quantitative immunohistology and image analysis. Mast cells were counted as tryptase-positive cells in the lamina propria, and substance P and VIP levels were expressed as percentages of total areas of staining. Mast cell counts were higher in IBS-D patients than healthy volunteers (9.6 ± 3.3 vs. 5.7 ± 2.5/high power field (HPF), p < 0.01). Substance P was also elevated (0.11 ± 0.08% vs. 0.03 ± 0.02 %, p < 0.01) while VIP was only high in women with IBS-D. Mast cell counts were positively correlated with levels of substance P & VIP in women but not men (women: r = 0.625, p < 0.01 for substance P and r = 0.651, p < 0.01 for VIP). However, mast cell counts were not correlated with IBS symptoms including abdominal pain. Mast cells are activated leading to the raised levels of substance P & VIP in IBS-D patients. However, the correlation between mast cells and levels of substance P & VIP differs according to gender.
Somasekar, A; James, L; Stephenson, B M; Thompson, I W; Vellacott, K D; Allison, M C
2009-09-01
To review all preceding 'negative' large bowel investigations in patients with a final diagnosis of colorectal cancer, and to examine whether delayed diagnosis was associated with worse outcome. Details were gathered on all patients with a new diagnosis of colorectal adenocarcinoma presenting over 4.5 years. For each patient the hospital's clinical workstation and radiology and endoscopy databases were interrogated for all flexible sigmoidoscopies, colonoscopies and barium enemas during the 5 years prior to diagnosis. Among the 570 patients, 28 (5%) had undergone colonoscopy and/or flexible sigmoidoscopy that had not shown colorectal cancer during the 5 years preceding final diagnosis, and a further 28 (5%) had undergone 'negative' barium enemas. Polyp surveillance might have missed four lesions destined to become malignant. Correspondingly there were three patients undergoing IBD surveillance found to have CRC, having had a negative complete colonoscopy within the preceding 5 years. Among patients undergoing de novo colonoscopy for diagnosis the true miss rate was only one patient per year. At August 2007, 29 (58%) of those with delayed diagnosis were still alive, compared with 216 (42%) of those diagnosed during initial investigation (chi2 = 5.04, P < 0.05). Colonoscopic miss rates are in line with previous studies. The application of simple clinical ground rules will avoid most pitfalls. The methodology described herein may assist in auditing the quality assurance of lower gastrointestinal diagnostic services. Despite the delay, late diagnosis was found to be associated with improved survival and a lower likelihood of metastatic disease.
Portillo Canizalez, Ligia Marcela; Blanco Rodriguez, Gerardo; Teyssier Morales, Gustavo; Penchyna Grub, Jaime; Trauernicht Mendieta, Sean; Zurita-Cruz, Jessie Nallely
Multiple intestinal preparations have been used in children undergoing colonoscopy, with variable limitation due to acceptance, tolerance, and proper cleaning. The objective of this study was to compare the tolerability, safety and efficacy of the colonoscopy preparation with 1 day with PEG 3350 (poliethylenglycol) (4g/kg/day) + bisacodyl compared to 2 days of preparation with PEG 3350 (2g/kg/day) + bisacodyl in pediatric patients. A clinical, randomized, and blind trial was performed. Patients aged 2 to 18 years scheduled for colonoscopy were included. Patients were randomized into two groups: 1 day of preparation with PEG 3350 4g/kg/day + bisacodyl and 2 days of preparation with PEG 3350 2g/kg/day + bisacodyl. Through a questionnaire, physical examination and endoscopic evaluation (Boston scale), the tolerance, safety and efficacy of the 2 preparations to be evaluated were determined. Student's t test was performed for quantitative variables and χ 2 for qualitative variables. There were no significant differences in compliance rates, adverse effects, and extent of colonoscopic evaluation. Tolerance and safety between the intestinal preparation for 1-day colonoscopy with PEG 3350 (4g/kg/day) + bisacodyl and the 2-day preparation with PEG 3350 (2g/kg/day) + bisacodyl were similar. The quality of cleanliness was good in both groups, being partially more effective in the 1-day group with PEG 3350 (4g/kg/day). Copyright © 2017 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Lee, Seung-Hwa; Kim, Kwang-Min; Seo, Sang-Wook; Kang, Joon-Koo; Lee, Eun-Hye; Lee, Dong-Ryul
2014-01-01
Purpose Bowel cleansing is generally regarded as time-consuming and unpleasant among patients. Patients commonly state that bowel preparation provokes more discomfort than the actual colonoscopic examination. The purpose of this study was to compare two regimens of sodium phosphate (NaP) tablets versus polyethylene glycol (PEG) solution for bowel preparation in healthy Korean adults. Materials and Methods This was a single center, prospective, open-label, investigator-blinded, randomized, controlled-pilot study. A total of 62 healthy Korean subjects were randomly assigned to two groups (NaP vs. PEG). Efficacy, safety, and patient-related outcomes, as well as procedural parameters, were evaluated. Results Although there were no significant differences in total Ottawa bowel quality score, fluid scores and the rate of adequate bowel preparation were significantly better in the NaP group than the PEG group. Additionally, the NaP group showed better results regarding patient tolerance, satisfaction, preference, and rate of adverse events than the PEG group. Significant fluctuations in specific serum electrolytes were common and of a greater magnitude in the NaP group than the PEG group. However, these abnormalities were transient and did not result in serious complications and side effects. Conclusion In this study, NaP tablets were shown to be an effective, well-tolerated, and acceptable regimen for bowel preparation. Also, our study suggests that NaP tablets may be safe and can be used as a bowel cleansing agent in healthy adults undergoing elective colonoscopy. Further multicenter, large scale studies are needed to confirm these findings. PMID:25323890
Buddingh, K Tim; Herngreen, Thomas; Haringsma, Jelle; van der Zwet, Wil C; Vleggaar, Frank P; Breumelhof, Ronald; Ter Borg, Frank
2011-06-01
Delayed hemorrhage is an infrequent, but serious complication of colonoscopic polypectomy. Large size is the only polyp-related factor that has been unequivocally proven to increase the risk of delayed bleeding. It has been suggested that location in the right hemi-colon is also a risk factor. The objective of this study was to determine whether polyp location is an independent risk factor for delayed post-polypectomy hemorrhage. A retrospective case-control study was conducted in two university hospitals and two community hospitals. Thirty-nine cases and 117 controls were identified. In multivariate analysis, size and location were found to be independent polyp-related risk factors for delayed type hemorrhage. The risk increased by 13% for every 1 mm increase in polyp diameter (odds ratio (OR) 1.13, 95% confidence interval (CI) 1.05-1.20, P<0.001). Polyps located in the right hemi-colon had an OR of 4.67 (1.88-11.61, P=0.001) for delayed hemorrhage. Polyps in the cecum seemed to be especially at high risk in univariate analysis (OR 13.82, 95% CI 2.66-71.73), but this could not be assessed in multivariate analysis as the number of cases was too small. Polyp type (sessile or pedunculated) was not a risk factor. Polyp location in the right hemi-colon seems to be an independent and substantial risk factor for delayed post-polypectomy hemorrhage. A low threshold for preventive hemostatic measures is advised when removing polyps from this region.
British Society of Gastroenterology position statement on serrated polyps in the colon and rectum.
East, James E; Atkin, Wendy S; Bateman, Adrian C; Clark, Susan K; Dolwani, Sunil; Ket, Shara N; Leedham, Simon J; Phull, Perminder S; Rutter, Matt D; Shepherd, Neil A; Tomlinson, Ian; Rees, Colin J
2017-07-01
Serrated polyps have been recognised in the last decade as important premalignant lesions accounting for between 15% and 30% of colorectal cancers. There is therefore a clinical need for guidance on how to manage these lesions; however, the evidence base is limited. A working group was commission by the British Society of Gastroenterology (BSG) Endoscopy section to review the available evidence and develop a position statement to provide clinical guidance until the evidence becomes available to support a formal guideline. The scope of the position statement was wide-ranging and included: evidence that serrated lesions have premalignant potential; detection and resection of serrated lesions; surveillance strategies after detection of serrated lesions; special situations-serrated polyposis syndrome (including surgery) and serrated lesions in colitis; education, audit and benchmarks and research questions. Statements on these issues were proposed where the evidence was deemed sufficient, and re-evaluated modified via a Delphi process until >80% agreement was reached. The Grading of Recommendations, Assessment, Development and Evaluations (GRADE) tool was used to assess the strength of evidence and strength of recommendation for finalised statements. Key recommendation : we suggest that until further evidence on the efficacy or otherwise of surveillance are published, patients with sessile serrated lesions (SSLs) that appear associated with a higher risk of future neoplasia or colorectal cancer (SSLs ≥10 mm or serrated lesions harbouring dysplasia including traditional serrated adenomas) should be offered a one-off colonoscopic surveillance examination at 3 years ( weak recommendation, low quality evidence, 90% agreement ). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Cosentino, Felice; Tumino, Emanuele; Passoni, Giovanni Rubis; Morandi, Elisabetta; Capria, Alfonso
2009-08-01
Currently, the best method for CRC screening is colonoscopy, which ideally (where possible) is performed under partial or deep sedation. This study aims to evaluate the efficacy of the Endotics System, a new robotic device composed of a workstation and a disposable probe, in performing accurate and well-tolerated colonoscopies. This new system could also be considered a precursor of other innovating vectors for atraumatic locomotion through natural orifices such as the bowel. The flexible probe adapts its shape to the complex contours of the colon, thereby exerting low strenuous forces during its movement. These novel characteristics allow for a painless and safe colonoscopy, thus eliminating all major associated risks such as infection, cardiopulmonary complications and colon perforation. An experimental study was devised to investigate stress pattern differences between traditional and robotic colonoscopy, in which 40 enrolled patients underwent both robotic and standard colonoscopy within the same day. The stress pattern related to robotic colonoscopy was 90% lower than that of standard colonoscopy. Additionally, the robotic colonoscopy demonstrated a higher diagnostic accuracy, since, due to the lower insufflation rate, it was able to visualize small polyps and angiodysplasias not seen during the standard colonoscopy. All patients rated the robotic colonoscopy as virtually painless compared to the standard colonoscopy, ranking pain and discomfort as 0.9 and 1.1 respectively, on a scale of O to 10, versus 6.9 and 6.8 respectively for the standard device. The new Endotics System demonstrates efficacy in the diagnosis of colonic pathologies using a procedure nearly completely devoid of pain. Therefore, this system can also be looked upon as the first step toward developing and implementing colonoscopy with atraumatic locomotion through the bowel while maintaining a high level of diagnostic accuracy;
dos Santos, Carlos Eduardo Oliveira; Moreira, Hamilton; Pereira-Lima, Julio Carlos; Ribas, Carmen Australia Paredes Marcondes; de Quadros Onófrio, Fernanda; Czecko, Alexandre Eduardo Augusti; Ramos, Rafael Koerich; de Carvalho, Caroline Aragão
2017-01-01
OBJECTIVES: The removal of pre-malignant colorectal lesions prevents cancer. Hyoscine has been proposed as a means of improving diagnosis by reducing colonic movements. The aim of this study was to analyze whether this anti-spasmodic enhances the detection of pre-malignant colorectal lesions. METHODS: In a randomized, double-blinded fashion patients received hyoscine or a saline solution in all consecutive colonoscopies in which the cecum was reached. Lesions were analysed with respect to number, size, location, histology and capillary pattern. RESULTS: A total of 440 colonoscopies were randomized. The overall polyp detection rate (PDR) and the adenoma detection rate (ADR) were 65.2% and 49.3%, respectively. In the hyoscine group, non-polypoid lesions were detected significantly more often (p=0.01). In the placebo group 281 lesions were diagnosed (202 adenomas) and in the hyoscine group 282 lesions were detected (189 adenomas) (p=0.23). The PDR and ADR were similar between the placebo and hyoscine groups (64% vs 66% and 50% vs 47%, respectively). No differences were observed between the two groups in the advanced-ADR or advanced neoplasia detection rate, as well the mean numbers of polyps, adenomas, advanced adenomas and advanced neoplasias detected per patient. The administration of hyoscine also did not improve the diagnostic accuracy of digital chromoendoscopy. The presence of adenomatous polyps in the right colon was detected significantly more frequently in the hyoscine group (OR 5.41 95% CI 2.7 - 11; p<0.01 vs OR 2.3 95% CI 1.1 - 4.6; p=0.02). CONCLUSION: The use of hyoscine before beginning the withdrawal of the colonoscope does not seem to enhance the PDR and the ADR. PMID:28792997
Dos Santos, Carlos Eduardo Oliveira; Moreira, Hamilton; Pereira-Lima, Julio Carlos; Ribas, Carmen Australia Paredes Marcondes; de Quadros Onófrio, Fernanda; Czecko, Alexandre Eduardo Augusti; Ramos, Rafael Koerich; de Carvalho, Caroline Aragão
2017-07-01
The removal of pre-malignant colorectal lesions prevents cancer. Hyoscine has been proposed as a means of improving diagnosis by reducing colonic movements. The aim of this study was to analyze whether this anti-spasmodic enhances the detection of pre-malignant colorectal lesions. In a randomized, double-blinded fashion patients received hyoscine or a saline solution in all consecutive colonoscopies in which the cecum was reached. Lesions were analysed with respect to number, size, location, histology and capillary pattern. A total of 440 colonoscopies were randomized. The overall polyp detection rate (PDR) and the adenoma detection rate (ADR) were 65.2% and 49.3%, respectively. In the hyoscine group, non-polypoid lesions were detected significantly more often (p=0.01). In the placebo group 281 lesions were diagnosed (202 adenomas) and in the hyoscine group 282 lesions were detected (189 adenomas) (p=0.23). The PDR and ADR were similar between the placebo and hyoscine groups (64% vs 66% and 50% vs 47%, respectively). No differences were observed between the two groups in the advanced-ADR or advanced neoplasia detection rate, as well the mean numbers of polyps, adenomas, advanced adenomas and advanced neoplasias detected per patient. The administration of hyoscine also did not improve the diagnostic accuracy of digital chromoendoscopy. The presence of adenomatous polyps in the right colon was detected significantly more frequently in the hyoscine group (OR 5.41 95% CI 2.7 - 11; p<0.01 vs OR 2.3 95% CI 1.1 - 4.6; p=0.02). The use of hyoscine before beginning the withdrawal of the colonoscope does not seem to enhance the PDR and the ADR.
Emmanuel, Andrew; Gulati, Shraddha; Burt, Margaret; Hayee, Bu'Hussain; Haji, Amyn
2018-05-01
Endoscopic resection of large colorectal polyps is well established. However, significant differences in technique exist between eastern and western interventional endoscopists. We report the results of endoscopic resection of large complex colorectal lesions from a specialist unit that combines eastern and western techniques for assessment and resection. Endoscopic resections of colorectal lesions of at least 2 cm were included. Lesions were assessed using magnification chromoendoscopy supplemented by colonoscopic ultrasound in selected cases. A lesion-specific approach to resection with endoscopic mucosal resection or endoscopic submucosal dissection (ESD) was used. Surveillance endoscopy was performed at 3 (SC1) and 12 (SC2) months. Four hundred and sixty-six large (≥20 mm) colorectal lesions (mean size 54.8 mm) were resected. Three hundread and fifty-six were resected using endoscopic mucosal resection and 110 by ESD or hybrid ESD. Fifty-one percent of lesions had been subjected to previous failed attempts at resection or heavy manipulation (≥6 biopsies). Nevertheless, endoscopic resection was deemed successful after an initial attempt in 98%. Recurrence occurred in 15% and could be treated with endoscopic resection in most. Only two patients required surgery for perforation. Nine patients had postprocedure bleeding; only two required endoscopic clips. Ninety-six percent of patients without invasive cancer were free from recurrence and had avoided surgery at last follow-up. Combining eastern and western practices for assessment and resection results in safe and effective organ-conserving treatment of complex colorectal lesions. Accurate assessment before and after resection using magnification chromoendoscopy and a lesion-specific approach to resection, incorporating ESD where appropriate, are important factors in achieving these results.
Aoki, Hironori; Yamamoto, Eiichiro; Yamano, Hiro-O; Sugai, Tamotsu; Kimura, Tomoaki; Tanaka, Yoshihito; Matsushita, Hiro-O; Yoshikawa, Kenjiro; Takagi, Ryo; Harada, Eiji; Nakaoka, Michiko; Yoshida, Yuko; Harada, Taku; Sudo, Gota; Eizuka, Makoto; Yorozu, Akira; Kitajima, Hiroshi; Niinuma, Takeshi; Kai, Masahiro; Nojima, Masanori; Suzuki, Hiromu; Nakase, Hiroshi
2018-03-15
Colorectal serrated lesions (SLs) are important premalignant lesions whose clinical and biological features are not fully understood. We aimed to establish accurate colonoscopic diagnosis and treatment of SLs through evaluation of associations among the morphological, pathological, and molecular characteristics of SLs. A total of 388 premalignant and 18 malignant colorectal lesions were studied. Using magnifying colonoscopy, microsurface structures were assessed based on Kudo's pit pattern classification system, and the Type II pit pattern was subcategorized into classical Type II, Type II-Open (Type II-O) and Type II-Long (Type II-L). BRAF/KRAS mutations and DNA methylation of CpG island methylator phenotype (CIMP) markers (MINT1, - 2, - 12, - 31, p16, and MLH1) were analyzed through pyrosequencing. Type II-O was tightly associated with sessile serrated adenoma/polyps (SSA/Ps) with BRAF mutation and CIMP-high. Most lesions with simple Type II or Type II-L were hyperplastic polyps, while mixtures of Type II or Type II-L plus more advanced pit patterns (III/IV) were characteristic of traditional serrated adenomas (TSAs). Type II-positive TSAs frequently exhibited BRAF mutation and CIMP-low, while Type II-L-positive TSAs were tightly associated with KRAS mutation and CIMP-low. Analysis of lesions containing both premalignant and cancerous components suggested Type II-L-positive TSAs may develop into KRAS-mutated/CIMP-low/microsatellite stable cancers, while Type II-O-positive SSA/Ps develop into BRAF-mutated/CIMP-high/microsatellite unstable cancers. These results suggest that Type II subtypes reflect distinct molecular subclasses in the serrated neoplasia pathway and that they could be useful hallmarks for identifying SLs at high risk of developing into CRC.
Novel endoscopic delivery modality of infrared coagulation therapy for internal hemorrhoids.
McLemore, Elisabeth C; Rai, Rudra; Siddiqui, Junaid; Basu, P Patrick; Tabbaa, Mousab; Epstein, Michael S
2012-11-01
A novel endoscopic delivery system for infrared coagulation therapy (IRC) has been designed recently. IRC is a well-established treatment for symptomatic internal hemorrhoids. Patients frequently undergo lower endoscopy before hemorrhoid treatment to eliminate other sources of bleeding. Current treatment options are difficult to perform without an anal retractor, adequate lighting, and specialized instruments. Endoscopic IRC is an attractive alternative to standard IRC, because it can be performed during the lower endoscopy. Endoscopic IRC utilizes infrared radiation generated by a control box, which is applied to the tissue through a flexible, fiber optic light guide (Precision Endoscopic Infrared Coagulator™). The light guide is placed through the colonoscope or flexible sigmoidoscope in the same chamber as other endoscopic instruments. A retrospective review was performed using a prospectively collected database. A standardized protocol was utilized in all patients. Patients graded their symptoms before and after therapy by using the visual analog symptom severity scoring system (range, 0-10). These results were analyzed by using the nonparametric Wilcoxon signed-rank test. Exact P values were computed by using the R function wilcox.exact. A total of 55 patients underwent endoscopic IRC for predominately grade II and grade III symptomatic internal hemorrhoids (71 %). There were 22 (40 %) female patients. Posttherapy results indicated a significant improvement in global symptoms (pretreatment average global score = 2.24 vs. posttreatment average global score = 0.28; P < 0.0001). There have been no adverse events reported to date. Endoscopic IRC provides improved visibility and efficiency, allowing simultaneous treatment of symptomatic internal hemorrhoids at the time of lower endoscopy. Patients experienced significant improvement in their symptoms after a single session of endoscopic IRC. There are a variety of additional endoscopic IRC therapeutic utilities: endoscopic management of angiodysplasia, inflammation, hemostasis, and NOTES applications.
Deiteren, Annemie; Vermeulen, Wim; Moreels, Tom G; Pelckmans, Paul A; De Man, Joris G; De Winter, Benedicte Y
2014-09-01
Visceral sensitivity is of pathophysiological importance in abdominal pain disorders and can be modulated by inflammation and stress. However, it is unclear whether inflammation and stress alter visceral perception independently of each other or in conjunction through neuroendocrine interactions. Therefore, we compared the short- and long-term effects of experimental colitis and water avoidance stress (WAS), alone or in combination, on visceral sensitivity in female Wistar rats. Colitis was induced by trinitrobenzene sulfonic acid (TNBS) and colonoscopically confirmed. During WAS, rats were placed on a platform surrounded by water for 1 h. Visceral sensitivity was assessed by quantifying the visceromotor responses (VMRs) to colorectal distension. Activation of the hypothalamic-pituitary-adrenal axis was determined by measuring serum corticosterone in a separate protocol. TNBS instillation resulted in overt colitis, associated with significant visceral hypersensitivity during the acute inflammatory phase (3 days post-TNBS; n = 8/group); after colitis had subsided (28 days post-TNBS), hypersensitivity was resolved (n = 4-8/group). Single WAS was associated with increased VMRs of a magnitude comparable to acute TNBS-induced hypersensitivity (n = 8/group). However, after repetitive WAS no significant hypersensitivity was present (n = 8/group). No additive effect of colitis and stress was seen on visceral pain perception (n = 6-8/group). Corticosterone levels were only increased in acute TNBS-colitis, acute WAS and their combination. To conclude, both colitis and stress successfully induced short-term visceral hypersensitivity and activated the hypothalamic-pituitary-adrenal axis, but long-term effects were absent. In addition, our current findings do not support an additive effect of colitis and stress on visceral sensitivity in female Wistar rats.
Validation of the second-generation Olympus colonoscopy simulator for skills assessment.
Haycock, A V; Bassett, P; Bladen, J; Thomas-Gibson, S
2009-11-01
Simulators have potential value in providing objective evidence of technical skill for procedures within medicine. The aim of this study was to determine face and construct validity for the Olympus colonoscopy simulator and to establish which assessment measures map to clinical benchmarks of expertise. Thirty-four participants were recruited: 10 novices with no prior colonoscopy experience, 13 intermediate (trainee) endoscopists with fewer than 1000 previous colonoscopies, and 11 experienced endoscopists with more than 1000 previous colonoscopies. All participants completed three standardized cases on the simulator and experts gave feedback regarding the realism of the simulator. Forty metrics recorded automatically by the simulator were analyzed for their ability to distinguish between the groups. The simulator discriminated participants by experience level for 22 different parameters. Completion rates were lower for novices than for trainees and experts (37 % vs. 79 % and 88 % respectively, P < 0.001) and both novices and trainees took significantly longer to reach all major landmarks than the experts. Several technical aspects of competency were discriminatory; pushing with an embedded tip ( P = 0.03), correct use of the variable stiffness function ( P = 0.004), number of sigmoid N-loops ( P = 0.02); size of sigmoid N-loops ( P = 0.01), and time to remove alpha loops ( P = 0.004). Out of 10, experts rated the realism of movement at 6.4, force feedback at 6.6, looping at 6.6, and loop resolution at 6.8. The Olympus colonoscopy simulator has good face validity and excellent construct validity. It provides an objective assessment of colonoscopic skill on multiple measures and benchmarks have been set to allow its use as both a formative and a summative assessment tool. Georg Thieme Verlag KG Stuttgart. New York.
Liu, Yen-Ling; Wu, Jin-Shang; Yang, Yi-Ching; Lu, Feng-Hwa; Lee, Chih-Ting; Lin, Wan-Ju; Chang, Chih-Jen
2018-04-01
Most cases of colorectal cancer develop via an adenoma to carcinoma sequence. Gallbladder polyps share some risk factors with colorectal polyps. Little is known about the relationship between gallbladder diseases and different status of colorectal polyps by gender. This study was to investigate the association of gallbladder stones and polyps with colorectal adenomas by gender in a Taiwanese population. A total of 7066 eligible subjects who underwent a total colonoscopy as a part of health check-up between January 2001 and August 2009 were recruited. Colonoscopic findings were classified into polyp-free, non-neoplastic polyps and colorectal adenomas. Gallbladder stones and gallbladder polyps were diagnosed based on ultrasonographic findings. There was a significant difference in the status of colon polyps between subjects with and without gallbladder polyps. However, the status of colon polyps was not significantly different between subjects with or without gallbladder stones. After adjusting obesity, fasting plasma glucose, and other variables, there was a positive relationship between gallbladder polyps and colorectal adenomas (odds ratio [OR]: 1.396, 95% confidence interval [CI]: 1.115-1.747) but not non-neoplastic polyps in all subjects. In men, gallbladder polyps (OR: 1.560, 95% CI: 1.204-2.019) and gallbladder stones (OR: 1.465, 95% CI 1.081-1.984) were positively associated with colorectal adenomas. In women, neither gallbladder polyps nor gallbladder stones were significantly related to colon polyps. Both gallbladder polyps and gallbladder stones were associated with an increased risk of colorectal adenomas in men but not in women. Gender difference was significant for the association between gallbladder lesions and colorectal polyps. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Chandran, S; Parker, F; Lontos, S; Vaughan, R; Efthymiou, M
2015-12-01
Polyps identified at colonoscopy are predominantly diminutive (<5 mm) with a small risk (>1%) of high-grade dysplasia or carcinoma; however, the cost of histological assessment is substantial. The aim of this study was to determine whether prediction of colonoscopy surveillance intervals based on real-time endoscopic assessment of polyp histology is accurate and cost effective. A prospective cohort study was conducted across a tertiary care and private community hospital. Ninety-four patients underwent colonoscopy and polypectomy of diminutive (≤5 mm) polyps from October 2012 to July 2013, yielding a total of 159 polyps. Polyps were examined and classified according to the Sano-Emura classification system. The endoscopic assessment (optical diagnosis) of polyp histology was used to predict appropriate colonoscopy surveillance intervals. The main outcome measure was the accuracy of optical diagnosis of diminutive colonic polyps against the gold standard of histological assessment. Optical diagnosis was correct in 105/108 (97.2%) adenomas. This yielded a sensitivity, specificity and positive and negative predictive values (with 95%CI) of 97.2% (92.1-99.4%), 78.4% (64.7-88.7%), 90.5% (83.7-95.2%) and 93% (80.9-98.5%) respectively. Ninety-two (98%) patients were correctly triaged to their repeat surveillance colonoscopy. Based on these findings, a cut and discard approach would have resulted in a saving of $319.77 per patient. Endoscopists within a tertiary care setting can accurately predict diminutive polyp histology and confer an appropriate surveillance interval with an associated financial benefit to the healthcare system. However, limitations to its application in the community setting exist, which may improve with further training and high-definition colonoscopes. © 2015 Royal Australasian College of Physicians.
Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.
2016-01-01
BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588
Bartley, Angela N; Parikh, Nila; Hsu, Chiu-Hsieh; Roe, Denise J; Buckmeier, Julie A; Corley, Lynda; Phipps, Ron A; Gallick, Gary; Lance, Peter; Thompson, Patricia A; Hamilton, Stanley R
2013-11-01
Cancer stem cells have tumor-initiation and tumor-maintenance capabilities. Stem-like cells are present in colorectal adenomas, but their relationship to adenoma pathology and patient characteristics, including metachronous development of an additional adenoma ("recurrence"), has not been studied extensively. We evaluated the expression of aldehyde dehydrogenase isoform 1A1 (ALDH1A1), a putative stem cell marker, in baseline adenomas from the placebo arm of chemoprevention trial participants with colonoscopic follow-up. An exploratory set of 20 baseline adenomas was analyzed by ALDH1A1 immunohistochemistry with morphometry, and a replication set of 89 adenomas from 76 high-risk participants was evaluated by computerized image analysis. ALDH1A1-labeling indices (ALI) were similar across patient characteristics and in advanced and nonadvanced adenomas. There was a trend toward higher ALIs in adenomas occurring in the right than left colon (P = 0.09). ALIs of synchronous adenomas were correlated (intraclass correlation coefficient 0.67). Participants in both sample sets who developed a metachronous adenoma had significantly higher ALIs in their baseline adenoma than participants who remained adenoma free. In the replication set, the adjusted odds for metachronous adenoma increased 1.46 for each 10% increase in ALIs (P = 0.03). A best-fit algorithm-based cutoff point of 22.4% had specificity of 75.0% and positive predictive value of 70.0% for metachronous adenoma development. A larger population of ALDH1A1-expressing cells in an adenoma is associated with a higher risk for metachronous adenoma, independent of adenoma size or histopathology. If confirmed, ALDH1A1 has potential as a novel biomarker in risk assessment and as a potential stem cell target for chemoprevention. ©2013 AACR
Bartley, Angela N.; Parikh, Nila; Hsu, Chiu-Hsieh; Roe, Denise J.; Buckmeier, Julie A.; Corley, Lynda; Phipps, Ron A.; Gallick, Gary; Lance, Peter; Thompson, Patricia A.; Hamilton, Stanley R.
2014-01-01
Cancer stem cells have tumor-initiation and tumor-maintenance capabilities. Stem-like cells are present in colorectal adenomas, but their relationship to adenoma pathology and patient characteristics, including metachronous development of an additional adenoma (“recurrence”), have not been studied extensively. We evaluated the expression of aldehyde dehydrogenase isoform 1A1 (ALDH1A1), a putative stem cell marker, in baseline adenomas from the placebo arm of chemoprevention trial participants with colonoscopic follow-up. An exploratory set of 20 baseline adenomas was analyzed by ALDH1A1 immunohistochemistry with morphometry, and a replication set of 89 adenomas from 76 high-risk participants was evaluated by computerized image analysis. ALDH1A1 labeling indices (ALIs) were similar across patient characteristics and in advanced and non-advanced adenomas. There was a trend toward higher ALIs in adenomas occurring in the right than left colon (p=0.09). ALIs of synchronous adenomas were correlated (intraclass correlation coefficient 0.67). Participants in both sample sets who developed a metachronous adenoma had significantly higher ALIs in their baseline adenoma than participants who remained adenoma-free. In the replication set, the adjusted odds for metachronous adenoma increased 1.46 for each 10% increase in ALIs (p=0.03). A best-fit algorithm-based cut-point of 22.4% had specificity of 75.0% and positive predictive value of 70.0% for metachronous adenoma development. A larger population of ALDH1A1-expressing cells in an adenoma is associated with a higher risk for metachronous adenoma, independent of adenoma size or histopathology. If confirmed, ALDH1A1 has potential as a novel biomarker in risk assessment and as a potential stem-cell target for chemoprevention. PMID:24008128
Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J
2016-03-15
New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.
Levitzky, Benjamin E; Brown, Colin C; Heeren, Timothy C; Schroy, Paul C
2011-06-01
Tailoring the use of screening colonoscopy based on the risk of advanced proximal neoplasia (APN) has been advocated as a strategy for reducing demand and optimizing effectiveness. A 7-point index based on age, sex, and distal findings at sigmoidoscopy has been proposed that stratifies individuals into low, intermediate, and high-risk categories. The aim of this cross-sectional analysis was to determine the validity of this index, which was originally derived and validated among mostly whites, for black and Hispanic patients. Data, including age, sex, colonoscopic findings, and pathology, were collected retrospectively from 1,481 white, 1,329 black, and 689 Hispanic asymptomatic, average-risk patients undergoing screening colonoscopy between 2000 and 2005. Cumulative scores ranging from 0 to 7 were derived for each subject and categorized as low, intermediate, or high risk. Rates of APN were assessed for each risk category after stratification by race/ethnicity. Index performance was assessed using the C-statistic and compared across the three racial groups. Rates of APN among patients categorized as low, intermediate, or high risk increased from 1.0 to 2.8 to 3.7% for whites, 1.0 to 2.2 to 4.2% for blacks, and 0.6 to 1.9 to 3.7% for Hispanics. The index performed similarly for all three groups, but showed limited ability to discriminate low from intermediate-risk patients, with C-statistic values of 0.62 for whites, 0.63 for blacks, and 0.68 for Hispanics. A risk index based on age, sex, and distal endoscopic findings has limited ability to discriminate low from intermediate-risk white, black, and Hispanic patients for APN.
Predictors of advanced colorectal neoplasia for colorectal cancer screening.
Wong, Martin C S; Lam, Thomas Y T; Tsoi, Kelvin K F; Chan, Victor C W; Hirai, Hoyee W; Ching, Jessica Y L; Sung, Joseph J Y
2014-05-01
The Asia-Pacific Colorectal Screening (APCS) score based on age, gender, family history, and smoking is useful to predict advanced colorectal neoplasia (ACN) in asymptomatic Asian subjects. To evaluate the factors in addition to those of APCS associated with ACN colonoscopic findings. Data from 5,220 asymptomatic subjects aged between 50 and 70 years who underwent screening colonoscopy in a community center between 2008 and 2012 were analyzed. One binary logistic regression analysis was conducted in 2013 with the presence of ACN or cancer as the outcome, controlling for APCS score, alcohol consumption, BMI, hypertension, and other chronic diseases as independent variables. The average participant age was 57.7 years (SD=4.9) and 47.5% were men. Advanced neoplasms or cancers were identified at colonoscopy in 5.6% of all screening participants. From multivariate regression analysis, APCS score≥4 (adjusted OR [AOR]=1.74, 95% CI=1.34, 2.25, p<0.001); overweight (BMI=23-24.9, AOR=1.52, 95% CI=1.12, 2.07, p=0.007); obesity (BMI≥25, AOR=1.56, 95% CI=1.15, 2.10, p=0.004); hypertension (AOR=1.58, 95% CI=1.21, 2.06, p=0.001); and alcohol consumption (AOR=1.47, 95% CI=1.05, 2.06, p=0.025) were associated with ACN. The c-statistic of APCS score alone was 0.560 (95% CI=0.524, 0.595, p=0.001) and that of APCS score plus BMI, hypertension, and alcohol consumption was 0.613 (95% CI=0.578, 0.648, p<0.001). Alcohol consumption, hypertension, and BMI are independent predictors of ACN, which could be incorporated into the APCS for prioritizing Asian asymptomatic subjects for colorectal cancer screening. Copyright © 2014. Published by Elsevier Inc.
Colonoscopic splenic injuries: incidence and management.
Kamath, Ashwin S; Iqbal, Corey W; Sarr, Michael G; Cullinane, Daniel C; Zietlow, Scott P; Farley, David R; Sawyer, Mark D
2009-12-01
Splenic injuries that occur during colonoscopies are rare. There is no available incidence of this serious complication, and the literature is limited to case reports. Our study looks at single institution experience of splenic injuries during colonoscopy to define the incidence and management of this serious complication. All patients from 1980 through June 2008 sustaining a splenic injury during colonoscopy were reviewed. Four patients (of 296,248 colonoscopies) sustained a splenic injury directly from colonoscopy performed at our institution (incidence 0.001%). Three additional patients were treated at our tertiary referral center after splenic injury from colonoscopy performed elsewhere. The mean age at the time of colonoscopy was 54 years (range 40-70 years). The most common presenting symptom was abdominal pain (n = 4) with a mean decrease in hemoglobin of 6.5 g/dl (range 4.5-8.5 g/dl). Splenic injury was diagnosed by computed tomography in five patients. Six patients received a mean of 5.5 U of packed red blood cells (range 2-14 U). All patients were managed with splenectomy, six patients within 24 h of the index colonoscopy, and one patient presented more than 24 h after initial colonoscopy. There was no evidence of preexisting splenic disease in any of the patients by surgical pathology, and there were no postoperative complications or deaths. The mean duration of stay was 10 days (range 7-15 days). All patients are alive at a median follow up of 22 months (range 1-164 months). Splenic injury occurring during colonoscopy is a rare but serious complication. Patients presented with abdominal pain and a precipitous decrease in hemoglobin and have all required emergent splenectomy.
Harker, JO; Leung, JW; Siao-Salera, RM; Mann, SK; Ramirez, FC; Friedland, S; Amato, A; Radaelli, F; Paggi, S; Terruzzi, V; Hsieh, YH
2011-01-01
Introduction Variation in outcomes in RcTs comparing water-related methods and air insufflation raises challenging questions regarding the new approach. This report reviews impact of water exchange - simultaneous infusion and removal of infused water during insertion on adenoma detection rate (ADR) defined as proportion of patients with a least one adenoma of any size. Methods Medline (2008–2011) searches, abstract of 2011 Digestive Disease Week (DDW) meeting and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of colonoscope. Results Since 2008, eleven reports of RcTs (6 published, 1 submitted and 4 abstracts, n=1728) described ADR in patients randomized to be examined by air and water-related methods. The water-related methods differed in timing of removal of the infused water -predominantly during insertion (water exchange) (n=825) or predominantly during withdrawal (water immersion) (n=903). Water immersion was associated with both increases and decreases in ADR compared to respective air method patients and the net overall change (-7%) was significant. On the other hand water exchange was associated with increases in ADR consistently and the net changes (overall, 8%; proximal overall, 11%; and proximal <10 mm, 12%) were all significant. Conclusion Comparative data generated the hypothesis that significantly larger increases in overall and proximal colon ADRs were associated with water exchange than water immersion or air insufflation during insertion. The hypothesis should be evaluated by RCTs to elucidate the mechanism of water exchange on adenoma detection. PMID:22163082
Harker, JO; Leung, JW; Siao-Salera, RM; Mann, SK; Ramirez, FC; Friedland, S; Amato, A; Radaelli, F; Paggi, S; Terruzzi, V; Hsieh, YH
2011-01-01
Introduction Variation in the outcomes in RcTs comparing water-related methods and air insufflation during the insertion phase of colonoscopy raises challenging questions regarding the approach. This report reviews the impact of water exchange on the variation in attenuation of pain during colonoscopy by water-related methods. Methods Medline (2008 to 2011) searches, abstracts of the 2011 Digestive Disease Week (DDW) and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of the colonoscope. Results: Since 2008 nine published and one submitted RcTs and five abstracts of RcTs presented at the 2011 DDW have been identified. Thirteen RcTs (nine published, one submitted and one abstract, n=1850) described reduction of pain score during or after colonoscopy (eleven reported statistical significance); the remaining reports described lower doses of medication used, or lower proportion of patients experiencing severe pain in colonoscopy performed with water-related methods compared with air insufflation (Tables 1 and 2). The water-related methods notably differ in the timing of removal of the infused water - predominantly during insertion (water exchange) versus predominantly during withdrawal (water immersion). Use of water exchange was consistently associated with a greater attenuation of pain score in patients who did not receive full sedation (Table 3). Conclusion The comparative data reveal that a greater attenuation of pain was associated with water exchange than water immersion during insertion. The intriguing results should be subjected to further evaluation by additional RcTs to elucidate the mechanism of the pain-alleviating impact of the water method. PMID:22163081
In-Vitro Archaeacidal Activity of Biocides against Human-Associated Archaea
Khelaifia, Saber; Michel, Jean Brunel; Drancourt, Michel
2013-01-01
Background Several methanogenic archaea have been detected in the human intestinal microbiota. These intestinal archaea may contaminate medical devices such as colonoscopes. However, no biocide activity has been reported among these human-associated archaea. Methodology The minimal archaeacidal concentration (MAC) of peracetic acid, chlorhexidine, squalamine and twelve parent synthetic derivatives reported in this study was determined against five human-associated methanogenic archaea including Methanobrevibacter smithii, Methanobrevibacter oralis, Methanobrevibacter arboriphilicus, Methanosphaera stadtmanae, Methanomassiliicoccus luminyensis and two environmental methanogens Methanobacterium beijingense and Methanosaeta concilii by using a serial dilution technique in Hungates tubes. Principal Findings MAC of squalamine derivative S1 was 0.05 mg/L against M. smithii strains, M. oralis, M. arboriphilicus, M. concilii and M. beijingense whereas MAC of squalamine and derivatives S2–S12 varied from 0.5 to 5 mg/L. For M. stadtmanae and M. luminyensis, MAC of derivative S1 was 0.1 mg/L and varied from 1 to ≥10 mg/L for squalamine and its parent derivatives S2–S12. Under the same experimental conditions, chlorhexidine and peracetic acid lead to a MAC of 0.2 and 1.5 mg/L, respectively against all tested archaea. Conclusions/Significance Squalamine derivative S1 exhibited a 10–200 higher archaeacidal activity than other tested squalamine derivatives, on the majority of human-associated archaea. As previously reported and due to their week corrosivity and their wide spectrum of antibacterial and antifungal properties, squalamine and more precisely derivative S1 appear as promising compounds to be further tested for the decontamination of medical devices contaminated by human-associated archaea. PMID:23658767
A new composite measure of colonoscopy: the Performance Indicator of Colonic Intubation (PICI).
Valori, Roland M; Damery, Sarah; Gavin, Daniel R; Anderson, John T; Donnelly, Mark T; Williams, J Graham; Swarbrick, Edwin T
2018-01-01
Cecal intubation rate (CIR) is an established performance indicator of colonoscopy. In some patients, cecal intubation with acceptable tolerance is only achieved with additional sedation. This study proposes a composite Performance Indicator of Colonic Intubation (PICI), which combines CIR, comfort, and sedation. METHODS : Data from 20 085 colonoscopies reported in the 2011 UK national audit were analyzed. PICI was defined as the percentage of procedures achieving cecal intubation with median dose (2 mg) of midazolam or less, and nurse-assessed comfort score of 1 - 3/5. Multivariate logistic regression analysis evaluated possible associations between PICI and patient, unit, colonoscopist, and diagnostic factors. RESULTS : PICI was achieved in 54.1 % of procedures. PICI identified factors affecting performance more frequently than single measures such as CIR and polyp detection, or CIR + comfort alone. Older age, male sex, adequate bowel preparation, and a positive fecal occult blood test as indication were associated with a higher PICI. Unit accreditation, the presence of magnetic imagers in the unit, greater annual volume, fewer years' experience, and higher training/trainer status were associated with higher PICI rates. Procedures in which PICI was achieved were associated with significantly higher polyp detection rates than when PICI was not achieved. CONCLUSIONS : PICI provides a simpler picture of performance of colonoscopic intubation than separate measures of CIR, comfort, and sedation. It is associated with more factors that are amenable to change that might improve performance and with higher likelihood of polyp detection. It is proposed that PICI becomes the key performance indicator for intubation of the colon in colonoscopy quality improvement initiatives. © Georg Thieme Verlag KG Stuttgart · New York.
Jensen, Dennis M.; Ohning, Gordon V.; Kovacs, Thomas O.G.; Jutabha, Rome; Ghassemi, Kevin; Dulai, Gareth S.; Machicado, Gustavo A.
2015-01-01
BACKGROUND AND AIMS Few prospective reports describe the short term natural history of colon diverticular hemorrhage based upon stigmata of recent hemorrhage and none include blood flow detection for risk stratification or as a guide to definitive hemostasis. Our purposes are to report the 30 day natural history of definitive diverticular hemorrhage based upon stigmata and to describe Doppler probe blood flow detection and as a guide to definitive hemostasis. METHODS Different cohorts of patients with severe diverticular bleeding and stigmata on urgent colonoscopy are reported. For 30 day natural history, patients were treated medically. If severe rebleeding occurred, they had surgical or angiographic treatment. Natural history with major stigmata (active bleeding, visible vessel, or adherent clot) and no stigmata or flat spots after washing away clots are reported. Doppler probe detection of arterial blood flow underneath stigmata before and after hemostasis is also reported in a recent cohort. RESULTS For natural history patients with major stigmata treated medically had 65.8% (25/38) rebleeding rates and 44.7% (17/38) had intervention for hemostasis. Patients with spots or clean bases had no rebleeding. Doppler probe detected arterial blood flow in 92% of major stigmata, none after hemostasis and no one rebled. CONCLUSIONS 1. Patients with major stigmata treated medically had high rates of rebleeding and intervention for hemostasis. 2. Patients with clean diverticula or only flat spots had no rebleeding. 3. High rates of arterial blood flow were detected under major stigmata with Doppler probe but with obliteration by hemostasis no rebleeding occurred. PMID:26227931
Clinical Features of Tuberculous Versus Crohn's Anal Fistulas, in Korea.
Choi, Yong-Sung; Kim, Do-Sun; Lee, Jae-Bum; Kim, Jong-Kyu; Jung, Hyung-Joong; Lee, Seong-Dae; Song, Kee-Ho; Lee, Doo-Han; Kim, Mi-Jung
2015-12-01
In Western countries, tuberculous anal fistula may not be an issue because tuberculosis [TB] is not common, and this is a very rare form of extrapulmonary manifestation of TB. However in TB-endemic countries, careful diagnostic differentiation is required because the clinical features of TB anal fistula and Crohn's disease [CD] anal fistula are similar, with distinguishing features remaining unclear. We aimed to analyse the clinical features of TB versus CD anal fistulas. Among 13872 patients who underwent anal fistula surgery from 2003 to 2014, 87 patients with TB fistulas and 116 patients with CD fistulas were included. Data on the annual incidence of TB and CD, as well as the clinical, pathological, ultrasonographic, colonoscopic and surgical data were analysed. Compared with CD, the TB group was older [median: 37 vs 22 years] and underlying chronic illness was more common [20.3% vs 2.6%]. In the TB group, 46 patients [59.7%] showed active or inactive pulmonary TB, and acid-fast bacilli and caseating granuloma were found in 56.3% and 62.1%, respectively. During colonoscopy, mucosal lesions were observed more frequently in CD [96.9% vs 16.9%]. TB anal fistula is clinically very similar to CD anal fistula. In Korea, the incidence of CD anal fistula has recently increased in prevalence, whereas the prevalence of TB anal fistula is decreasing but is still persistent. We recommend that clinicians should prepare for a possibility of TB as well as CD anal fistula in TB-endemic countries including Korea. Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Gonzalez, Baldomero; Vargas, Guadalupe; Mendoza, Victoria; Nava, Mariana; Rojas, Moisés; Mercado, Moisés
2017-05-01
Acromegaly is associated with an increased risk of colonic polyps. The magnitude of such risk is controversial, and the characteristics that distinguish patients who develop polyps from those who do not are not well established. This study was performed to determine the prevalence of colonic polyps upon the diagnosis of acromegaly and to compare the clinical and biochemical features of patients with and without polyps. Out of 165 patients who underwent a full colonoscopy upon diagnosis of acromegaly, 53 were found to harbor colonic lesions (cases), whereas the remaining 112 were used as controls. Demographic, clinical, and biochemical characteristics were compared between the 2 groups. The prevalence of colonic polyps was 32%, with an estimated relative risk of 6.21 (95% confidence interval [CI] 4.08-9.48). Adenomatous and nonadenomatous polyps were found in 22 and 31 patients, respectively. The most common location was the descending colon. Compared to patients without polyps, subjects with polyps were somewhat older and had significantly higher insulin-like growth factor-1 (IGF-1) levels and a higher prevalence of diabetes. Upon multivariate analysis, only IGF-1 level at diagnosis remained significantly associated with colonic polyps in general and with hyperplastic polyps in particular. Acromegaly is associated with an elevated risk of developing colonic polyps, particularly, distally located hyperplastic lesions. Except for a higher IGF-1 level at diagnosis, no distinctive clinical or biochemical features can be found among those who develop polyps compared to those who do not. CI = confidence interval GH = growth hormone IGF-1 = insulin-like growth factor 1 IQR = inter-quartile range RR = relative risk ULN = upper limit of normal.
Thompson, Patricia; Roe, Denise J; Fales, Liane; Buckmeier, Julie; Wang, Fang; Hamilton, Stanley R; Bhattacharyya, Achyut; Green, Sylvan; Hsu, Chiu-Hsieh; Chow, H-H Sherry; Ahnen, Dennis J; Boland, C Richard; Heigh, Russell I; Fay, David E; Martinez, Maria Elena; Jacobs, Elizabeth; Ashbeck, Erin L; Alberts, David S; Lance, Peter
2012-12-01
COX inhibitors reduce colorectal adenoma recurrence by up to 45% and selenium supplementation may prevent colorectal cancer. Following colonoscopic adenoma resection, 1,600 men and women, ages 40 to 80 years, were randomized to celecoxib (400 mg daily), a selective COX-2 inhibitor, and/or selenium (200 μg daily as selenized yeast), or double placebo. The trial was initiated in November 2001. The primary trial endpoint is adenoma recurrence in each intervention group compared with placebo, as determined by surveillance colonoscopy conducted three to five years after baseline. Randomization was stratified by use of low-dose aspirin (81 mg) and clinic site. Following reports of cardiovascular toxicity associated with COX-2 inhibitors, the celecoxib arm was discontinued in December 2004 when 824 participants had been randomized. Accrual continued with randomization to selenium alone or placebo. Randomization of the originally planned cohort (n = 1,621) was completed in November 2008. A further 200 patients with one or more advanced adenomas (denoting increased risk for colorectal cancer) were accrued to enhance statistical power for determining intervention efficacy in this higher-risk subgroup. Accrual of the total cohort (n = 1,824) was completed in January 2011. Baseline cohort characteristics include: mean age 62.9 years; 65% male; body mass index (BMI) 29.1 ± 5.1; 47% taking low-dose aspirin while on trial; 20% with three or more adenomas; and 38% with advanced adenomas. Intervention effects on adenoma recurrence will be determined, and their modification by genetic background and baseline selenium level. The effect of selenium supplementation on risk for type II diabetes will also be reported. ©2012 AACR
Higher prevalence of colon polyps in patients with Barrett’s esophagus: a case-control study
Kumaravel, Arthi; Thota, Prashanthi N.; Lee, Hyun-Ju; Gohel, Tushar; Kanadiya, Mehulkumar K.; Lopez, Rocio; Sanaka, Madhusudhan R.
2014-01-01
Background and aims: Barrett’s esophagus (BE) and colorectal neoplasms share similar risk factors. Previous studies have shown variable prevalence of colon polyps in patients with BE. Our aims were to determine the prevalence and incidence of colon polyps in patients with BE, compared to those without BE. Methods: In this case-control study, the study group included patients, aged 50–75 years, with biopsy-proven BE, who underwent colonoscopy at Cleveland Clinic from January 2002 to December 2011. The control group consisted of age- and sex-matched patients who underwent colonoscopy and also an endoscopy with no evidence of BE during the same time period. Exclusion criteria for both groups were family- or personal previous history of colon cancer or polyps, prior colonic resection, inflammatory bowel disease and familial polyposis syndromes. Patient demographics, comorbidities, medication use and endoscopic and colonoscopic details were collected, including biopsy results. Results: A total of 519 patients were included in the study; 173 patients with BE in the study group and 346 without BE in the control group. Mean age at index colonoscopy was 61 ± 8 years and 75% of patients were male. On index colonoscopy, patients with BE were more likely to have polyps than controls (45% vs 32%, respectively; P = 0.003). Patients underwent between one and five colonoscopies during the follow-up. On multivariate analysis—after adjusting for age, gender and diabetes—patients with BE were 80% more likely to have any type of polyp, and 50% more likely to have adenomas found during colonoscopy. Conclusions: Patients with BE had higher prevalence and incidence of colon polyps. This has important clinical implications for screening and surveillance in BE patients. PMID:25085954
Brenner, Hermann; Altenhofen, Lutz; Stock, Christian; Hoffmeister, Michael
2014-09-01
Most colorectal cancers develop from adenomas. We aimed to estimate sex- and age-specific incidence rates of colorectal adenomas and to assess their potential implications for colorectal cancer screening strategies. Sex- and age-specific incidence rates of colorectal adenomas were derived by a birth cohort analysis using data from 4,322,085 screening colonoscopies conducted in Germany and recorded in a national database in 2003-2012. In addition, cumulative risks of colorectal cancer among colonoscopically neoplasm-free men and women were estimated by combining adenoma incidence rates with previously derived adenoma-colorectal cancer transition rates. Estimated annual incidence in percentage (95% confidence interval) in age groups 55-59, 60-64, 65-69, 70-74, and 75-79 was 2.4 (2.2-2.6), 2.3 (2.1-2.6), 2.4 (2.1-2.6), 2.2 (1.8-2.5), and 1.8 (1.2-2.3) among men, and 1.4 (1.3-1.5), 1.5 (1.4-1.7), 1.6 (1.4-1.8), 1.6 (1.3-1.8), and 1.2 (0.8-1.6) among women. Estimated 10- and 15-year risks of clinically manifest colorectal cancer were 0.1% and 0.5% or lower, respectively, in all groups assessed. Annual incidence rates of colorectal adenomas are below 2.5% and 2% among men and women, respectively, and show little variation by age. Risk of clinically manifest colorectal cancer is expected to be very small within 10 years and beyond after negative colonoscopy for men and women at all ages. The use of rescreening after a negative screening colonoscopy above 60 years of age may be very limited. ©2014 American Association for Cancer Research.
Kilambi, Vikram; Johnson, F Reed; González, Juan Marcos; Mohamed, Ateesha F
2014-12-01
The value of the information that genetic testing services provide can be questioned for insurance-based health systems. The results of genetic tests oftentimes may not lead to well-defined clinical interventions; however, Lynch syndrome, a genetic mutation for which carriers are at an increased risk for colorectal cancer, can be identified through genetic testing, and meaningful health interventions are available via increased colonoscopic surveillance. Valuations of test information for such conditions ought to account for the full impact of interventions and contingent outcomes. To conduct a discrete-choice experiment to elicit individuals' preferences for genetic test information. A Web-enabled discrete-choice experiment survey was administered to a representative sample of US residents aged 50 years and older. In addition to specifying expenditures on colonoscopies, respondents were asked to make a series of nine selections between two hypothetical genetic tests or a no-test option under the premise that a relative had Lynch syndrome. The hypothetical genetic tests were defined by the probability of developing colorectal cancer, the probability of a false-negative test result, privacy of the result, and out-of-pocket cost. A model specification identifying necessary interactions was derived from assumptions of risk behavior and the decision context and was estimated using random-parameters logit. A total of 650 respondents were contacted, and 385 completed the survey. The monetary equivalent of test information was approximately $1800. Expenditures on colonoscopies to reduce mortality risks affected valuations. Respondents with lower income or who reported being employed significantly valued genetic tests more. Genetic testing may confer benefits through the impact of subsequent interventions on private individuals. Copyright © 2014. Published by Elsevier Inc.
Wanders, Linda K; Dekker, Evelien; Pullens, Bo; Bassett, Paul; Travis, Simon P L; East, James E
2014-05-01
American and European guidelines propose complete endoscopic resection of polypoid dysplasia (adenomas or adenoma-like masses) in patients with longstanding colitis, with close endoscopic follow-up. The incidence of cancer after detection of flat low-grade dysplasia or dysplasia-associated lesion or mass is estimated at 14 cases/1000 years of patient follow-up. However, the risk for polypoid dysplasia has not been determined with precision. We investigated the risk of cancer after endoscopic resection of polypoid dysplasia in patients with ulcerative colitis. MEDLINE, EMBASE, PubMed, and the Cochrane library were searched for studies of patients with colitis and resected polypoid dysplasia, with reports of colonoscopic follow-up and data on cancers detected. Outcomes from included articles were pooled to provide a single combined estimate of outcomes by using Poisson regression. Of 425 articles retrieved, we analyzed data from 10 studies, comprising 376 patients with colitis and polypoid dysplasia with a combined 1704 years of follow-up. A mean of 2.8 colonoscopies were performed for each patient after the index procedure (range, 0-15 colonoscopies). The pooled incidence of cancer was 5.3 cases (95% confidence interval, 2.7-10.1 cases)/1000 years of patient follow-up. There was no evidence of heterogeneity or publication bias. The pooled rate of any dysplasia was 65 cases (95% confidence interval, 54-78 cases)/1000 patient years. Patients with colitis have a low risk of colorectal cancer after resection of polypoid dysplasia; these findings support the current strategy of resection and surveillance. However, these patients have a 10-fold greater risk of developing any dysplasia than colorectal cancer and should undergo close endoscopic follow-up. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.
Daly, Patricia E; Samiee, Sara; Cino, Maria; Gryfe, Robert; Pollett, Aaron; Ng, Andrea; Constine, Louis S; Hodgson, David C
2017-10-01
Cancer survivors treated with abdominal/pelvic radiation therapy (ART) have increased the risks of colorectal cancer (CRC), although evidence supporting early CRC screening for these patients is lacking. We sought to determine whether there is an elevated prevalence of adenomatous colorectal polyps in young survivors prior to the age when screening would be routinely recommended. We conducted a prospective study of early colonoscopic screening in cancer survivors aged 35-49 who had received ART ≥10 years previously. The planned sample size was based on prior studies reporting a prevalence of adenomatous polyps of approximately 20% among the average-risk population ≥50 years of age, in contrast to ≤10% among those average-risk people aged 40-50 years, for whom screening is not routinely recommended. Colonoscopy was performed in 54 survivors, at a median age of 45 years (range 36-49) and after median interval from radiation treatment of 19 years (10.6-43.5). Forty-nine polyps were detected in 24 patients, with 15 patients (27.8%; 95% CI 17.6% to 40.9%) having potentially precancerous polyps. Fifty-three per cent of polyps were within or at the edge of the prior ART fields. Young survivors treated with ART have a polyp prevalence comparable with the average-risk population aged ≥50 years and substantially higher than previously reported for the average-risk population aged 40-50 years. These findings lend support to the early initiation of screening in these survivors. NCT00982059; results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Khuhaprema, Thiravud; Sangrajrang, Suleeporn; Lalitwongsa, Somkiat; Chokvanitphong, Vanida; Raunroadroong, Tawarat; Ratanachu-ek, Tawee; Muwonge, Richard; Lucas, Eric; Wild, Christopher; Sankaranarayanan, Rengaswamy
2014-01-01
Objective Colorectal cancer (CRC) is the third-most and fifth-most common cancer in men and women, in Thailand. The increasing CRC incidence and mortality can be reduced by screening and treating adenomas and early cancers. A pilot CRC screening programme using immunochemical faecal occult blood testing (iFOBT) and colonoscopy for test-positives were implemented through the routine Government Health Services in Lampang Province, to inform the acceptability, feasibility and scaling-up of screening in Thailand. This report describes the implementation, coverage and performance indicators of this project. Design A target population aged 50–65 years was informed about and invited face to face to undergo CRC screening by community health workers (HWs). The HWs provided faecal sample collection kits and participants brought their samples to one of the primary health units or community hospitals where nurses performed iFOBT. iFOBT-positive persons were referred for colonoscopy at the Lampang cancer hospital, and endoscopic polypectomy/biopsies were performed according to the colonoscopic findings. Those with confirmed CRC received appropriate treatment. Results Of the 127 301 target population, 62.9% were screened using iFOBT between April 2011 and November 2012. Participation was higher among women (67.8%) than men (57.8%) and lower in 50–54 year-old persons than in 60–65-year-olds. Of those screened, 873 (1.1%) were found positive; positivity was higher in men (1.2%) than in women (1.0%). To date 627 (72.0%) iFOBT-positive persons have had colonoscopy in which 3.7% had CRC and 30.6% had adenomas. Conclusions The successful implementation of the pilot CRC screening with satisfactory process measures indicate the feasibility of scaling-up organised CRC screening through existing health services in Thailand. PMID:24435889
Endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy
Wang, Fei; Xu, Boming; Li, Quanpeng; Zhang, Xiuhua; Jiang, Guobing; Ge, Xianxiu; Nie, Junjie; Zhang, Xiuyun; Wu, Ping; Ji, Jie; Miao, Lin
2016-01-01
Abstract Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is challenging. Results of ERCP in those patients varied. The aim of our study was to evaluate the safety and effectiveness of various endoscopes-assisted ERCP in patients with surgically altered anatomy. Fifty-two patients with Billroth II reconstruction (group A), 20 patients with subtotal or total gastrectomy with Roux-en-Y anastomosis (group B), 25 patients with pancreatoduodenectomy or Roux-en-Y hepaticojejunostomy reconstruction (group C) were included. Gastroscope, duodenoscope, colonoscope, and double-balloon enteroscope were used. The endoscope insertion success rate of groups A, B, C was 96.2% (50/52), 85.0% (17/20), 80% (20/25), respectively. χ2 test showed that there was no significant difference between the 3 groups (P = 0.068). The mean insertion time was 36.7, 68.4, and 84.0 minutes, respectively. One-way ANOVA showed that the insertion time of group C was significantly longer than that of groups B and C (both P <0.001). The endoscopic cannulation success rates of groups A, B, C were 90%, 82.4%, and 100%, respectively. χ2 test showed that there was no significant difference between the 3 groups (P = 0.144). The mean cannulation time was 19.4, 28.1, and 20.4 minutes, respectively. One-way ANOVA showed that the cannulation time of group B was longer than that of groups A and C (P <0.001, P = 0.001, respectively). In total, 74 patients with successful biliary cannulation achieved the therapeutic goal; thus, the clinical success rate was 76.3% (74/97). Our study showed that ERCP in patients with surgically altered anatomy was safe and feasible. PMID:28033284
White, Ian; Buchberg, Brian; Tsikitis, V Liana; Herzig, Daniel O; Vetto, John T; Lu, Kim C
2014-06-01
Colorectal cancer is the second most common cause of death in the USA. The need for screening colonoscopies, and thus adequately trained endoscopists, particularly in rural areas, is on the rise. Recent increases in required endoscopic cases for surgical resident graduation by the Surgery Residency Review Committee (RRC) further emphasize the need for more effective endoscopic training during residency to determine if a virtual reality colonoscopy simulator enhances surgical resident endoscopic education by detecting improvement in colonoscopy skills before and after 6 weeks of formal clinical endoscopic training. We conducted a retrospective review of prospectively collected surgery resident data on an endoscopy simulator. Residents performed four different clinical scenarios on the endoscopic simulator before and after a 6-week endoscopic training course. Data were collected over a 5-year period from 94 different residents performing a total of 795 colonoscopic simulation scenarios. Main outcome measures included time to cecal intubation, "red out" time, and severity of simulated patient discomfort (mild, moderate, severe, extreme) during colonoscopy scenarios. Average time to intubation of the cecum was 6.8 min for those residents who had not undergone endoscopic training versus 4.4 min for those who had undergone endoscopic training (p < 0.001). Residents who could be compared against themselves (pre vs. post-training), cecal intubation times decreased from 7.1 to 4.3 min (p < 0.001). Post-endoscopy rotation residents caused less severe discomfort during simulated colonoscopy than pre-endoscopy rotation residents (4 vs. 10%; p = 0.004). Virtual reality endoscopic simulation is an effective tool for both augmenting surgical resident endoscopy cancer education and measuring improvement in resident performance after formal clinical endoscopic training.
Koulaouzidis, Anastasios; Yung, Diana E.; Nemeth, Artur; Sjöberg, Klas; Giannakou, Andry; Qureshi, Raheel; Bartzis, Leonidas; McNeill, Morna; Johansson, Gabriele Wurm; Lucendo, Alfredo J.; Fineron, Paul; Trimble, Ken C.; Saeed, Athar; Plevris, John N.; Toth, Ervin
2017-01-01
Background Collagenous colitis (CC) is by definition a histological diagnosis. However, colonoscopy often reveals characteristic endoscopic findings. The aim of this study was to evaluate the frequency and type of endoscopic findings in patients diagnosed with CC in 4 participating centers. Methods This was a retrospective study; the databases of 2 university hospitals in Edinburgh (Scotland) and Malmö (Sweden), and 2 district general hospitals in Tomelloso (Spain) and Gateshead (England) were interrogated for patients diagnosed with CC between May 2008 and August 2013. Endoscopy reports and images were retrieved and reviewed; data on lesions, sedation, bowel preparation and endoscopist experience were abstracted. Categorical data are reported as mean±SD. Fischer’s exact, chi-square and t (unpaired) tests were used to compare datasets. A two-tailed P-value of <0.05 was considered statistically significant. Results 607 patients (149 male, mean age 66.9±12.25 years) were diagnosed with CC. A total of 108/607 (17.8%) patients had one or more suggestive endoscopy findings: i.e., mucosal erythema/edema, 91/607 (15%); linear colonic mucosal defects, 12/607 (2%); or mucosal scarring, 5/607 (0.82%). For colonic mucosa erythema, there was no difference in the odds of finding erythema with the use of different bowel preparation methods (P=0.997). For colonic mucosal defects there was some evidence (P=0.005) that patients colonoscoped by experienced endoscopists had 87% less odds of developing such defects. Moreover, there was evidence that analgesia reduced the odds of developing mucosal defects by 84%. Conclusion A significant minority of patients with CC have endoscopic findings in colonoscopy. The description of such findings appears to be related to the endoscopist’s experience. PMID:28469361
Haraguchi, Naotsugu; Ikeda, Masataka; Miyake, Masakazu; Yamada, Takuya; Sakakibara, Yuko; Mita, Eiji; Doki, Yuichiro; Mori, Masaki; Sekimoto, Mitsugu
2016-11-01
To clarify the advantages and disadvantages of stenting as a bridge to surgery (BTS) by comparing the clinical features and outcomes of patients who underwent BTS with those of patients who underwent emergency surgery (ES). We assessed technical success, clinical success, surgical procedures, stoma formation, complications, clinicopathological features, and Onodera's prognostic nutritional index (OPNI) in patients who underwent BTS and those who underwent ES. Twenty-six patients underwent stenting, which was successful in 22 (BTS group). The remaining four patients with unsuccessful stenting underwent emergency surgery. A total of 22 patients underwent emergency surgery (ES group). The rates of technical and clinical success were 85.0 and 81.0 %, respectively. The proportion of patients able to be treated by laparoscopic surgery (P = 0.0001) and avoid colostomy (P = 0.0042) was significantly higher in the BTS group. Although the incidence of anastomotic leakage in the two groups was not significantly different, it was significantly reduced by colonoscopic evaluation of obstructive colitis (P = 0.0251). The mean number of harvested lymph nodes (P = 0.0056) and the proportion of D3 lymphadenectomy (P = 0.0241) were significantly greater in the BTS group. Perineural invasion (PNI) was noted in 59.1 and 18.2 % of the BTS group and ES group patients, respectively (P = 0.0053). OPNI and serum albumin decreased significantly after stenting (P = 0.0084). The advantages of stenting as a BTS were that it avoided colostomy and allowed for laparoscopic surgery and lymphadenectomy, whereas its disadvantage lay in the decreased PNI and OPNI levels. A larger study including an analysis of prognosis is warranted.
Rajasekhar, P T; Clifford, G M; Lee, T J W; Rutter, M D; Waddup, G; Ritchie, M; Nylander, D; Painter, J; Singh, J; Ward, I; Dempsey, N; Bowes, J; Handley, G; Henry, J; Rees, C J
2012-01-01
The NHS Bowel Cancer Screening Programme (BCSP) began roll-out in 2006 aiming to reduce cancer mortality through detection at an earlier stage. We report results from the prevalent round of screening at two first wave centres and compare with the UK pilot study. This is a service evaluation study. Data were collected prospectively for all individuals undergoing faecal occult blood testing (FOBt) and colonoscopy including: uptake and outcomes of FOBt, colonoscopic performance, findings, histological data and complications. Continuous data were compared using a two-tailed test of two proportions. The South of Tyne and Tees Bowel Cancer Screening centres. Participants of the BCSP. 1) Colonoscopy Quality Assurance and 2) Cancer stage shift. 195,772 individuals were invited to participate. Uptake was 54% and FOBt positivity 1.7%. 1524 underwent colonoscopy with caecal intubation in 1485 (97%). 180 (12%) cancers were detected. Dukes stages were: 76 (42%) A; 47 (26%) B; 47 (26%) C; 8 (4%) D and 2 (1%) unknown. This demonstrates a significantly earlier stage at diagnosis compared with data from 2867 non-screening detected cancers (p<0.001). Adenomas were detected in 758 (50%). One perforation occurred (0.07%) and two intermediate bleeds requiring transfusion only (0.12%). Both caecal intubation and adenoma detection were significantly higher than in the UK pilot study (p<0.001). The prevalent round of screening demonstrates a high adenoma and cancer detection rate and significantly earlier stage at diagnosis. Complications were few providing reassurance regarding safety. Efforts are required to improve uptake.
Rajasekhar, P T; Clifford, G M; Lee, T J W; Rutter, M D; Waddup, G; Ritchie, M; Nylander, D; Painter, J; Singh, J; Ward, I; Dempsey, N; Bowes, J; Handley, G; Henry, J; Rees, C J
2012-01-01
Objective The NHS Bowel Cancer Screening Programme (BCSP) began roll-out in 2006 aiming to reduce cancer mortality through detection at an earlier stage. We report results from the prevalent round of screening at two first wave centres and compare with the UK pilot study. Design This is a service evaluation study. Data were collected prospectively for all individuals undergoing faecal occult blood testing (FOBt) and colonoscopy including: uptake and outcomes of FOBt, colonoscopic performance, findings, histological data and complications. Continuous data were compared using a two-tailed test of two proportions. Setting The South of Tyne and Tees Bowel Cancer Screening centres. Patients Participants of the BCSP. Main Outcome Measures 1) Colonoscopy Quality Assurance and 2) Cancer stage shift. Results 195,772 individuals were invited to participate. Uptake was 54% and FOBt positivity 1.7%. 1524 underwent colonoscopy with caecal intubation in 1485 (97%). 180 (12%) cancers were detected. Dukes stages were: 76 (42%) A; 47 (26%) B; 47 (26%) C; 8 (4%) D and 2 (1%) unknown. This demonstrates a significantly earlier stage at diagnosis compared with data from 2867 non-screening detected cancers (p<0.001). Adenomas were detected in 758 (50%). One perforation occurred (0.07%) and two intermediate bleeds requiring transfusion only (0.12%). Both caecal intubation and adenoma detection were significantly higher than in the UK pilot study (p<0.001). Conclusions The prevalent round of screening demonstrates a high adenoma and cancer detection rate and significantly earlier stage at diagnosis. Complications were few providing reassurance regarding safety. Efforts are required to improve uptake. PMID:28839624
Mirinezhad, Seyed Kazem; Mousavi, Farideh; Baghri, Masood; Sepehri, Bita; Ghavidel, Ali; Ghojazadeh, Morteza; Somi, Mohammad Hossein
2018-01-27
Objective: Familial adenomatous polyposis (FAP), an autosomal dominant inherited disorder is characterized by the presence of multiple adenomatous colorectal polyps, which can develop into cancer during early adulthood. Therefore, early diagnosis is essential. Most FAP patients have several extracolonic manifestations, including congenital hypertrophy of the retinal pigment epithelium (CHRPE). Whereas genetic markers may provide the main route to detection of ‘‘at risk’’ subjects , at present this approach is clearly limited and searches for a noninvasive phenotypic marker continue to be high priority.The aim of this study was to describe the pattern of distribution of CHRPE lesions and evaluate their diagnostic value in FAP patients and their family members in a local population. Methods: A total of 23 FAP patients and 26 relatives belonging to 12 families at high risk of developing FAP were subjected to colonoscopic and ophthalmological examination. Result: Retinal examinations demonstrated prevalences of CHRPE in FAP patents and their siblings of 78% and 38%, respectively. We were able to illustrate a significant correlation between FAP disease and the presence of retinal lesions. Sensitivity and specificity of CHRPE as a screening test to detect the presence of FAP are 78.3% and 61.5%, respectively, with a positive predictive value of 64.3% and a negative predictive value of 76.2 %. A “lesion form” significant difference was found between FAP and normal participants.Spearman nonparametric analysis revealed no correlation between age and number or size of lesions. Conclusion: Multiple CHRPE lesions are a diagnostic feature of FAP patients They are specific and sensitive clinical markers of this disease (specificity 60% and sensitivity 77%). Creative Commons Attribution License
Design and preliminary evaluation of a self-steering, pneumatically driven colonoscopy robot.
Dehghani, Hossein; Welch, C Ross; Pourghodrat, Abolfazl; Nelson, Carl A; Oleynikov, Dmitry; Dasgupta, Prithviraj; Terry, Benjamin S
2017-04-01
Colonoscopy is a diagnostic procedure to detect pre-cancerous polyps and tumours in the colon, and is performed by inserting a long tube equipped with a camera and biopsy tools. Despite the medical benefits, patients undergoing this procedure often complain about the associated pain and discomfort. This discomfort is mostly due to the rough handling of the tube and the creation of loops during the insertion. The overall goal of this work is to minimise the invasiveness of traditional colonoscopy. In pursuit of this goal, this work presents the development of a semi-autonomous colonoscopic robot with minimally invasive locomotion. The proposed robotic approach allows physicians to concentrate mainly on the diagnosis rather than the mechanics of the procedure. In this paper, an innovative locomotion approach for robotic colonoscopy is addressed. Our locomotion approach takes advantage of longitudinal expansion of a latex tube to propel the robot's tip along the colon. This soft and compliant propulsion mechanism, in contrast to minimally invasive mechanisms used in, for example, inchworm-like robots, has shown promising potential. In the preliminary ex vivo experiments, the robot successfully advanced 1.5 metres inside an excised curvilinear porcine colon with average speed of 28 mm/s, and was capable of traversing bends up to 150 degrees. The robot creates less than 6 N of normal force at its tip when it is pressurised with 90 kPa. This maximum force generates pressure of 44.17 mmHg at the tip, which is significantly lower than safe intraluminal human colonic pressure of 80 mmHg. The robot design inherently prevents loop formation in the colon, which is recognised as the main cause of post procedural pain in patients. Overall, the robot has shown great promise in an ex vivo experimental setup. The design of an autonomous control system and in vivo experiments are left as future work.
RASTREO DEL CANCER COLORRECTAL CONOCIMIENTO Y ACTITUD DE LA POBLACION
CASAL, ENRIQUE R.; VELAZQUEZ, ELIZABETH N.; MEJIA, RAUL M.; CUNEO, ALDO; PEREZ-STABLE, ELISEO J.
2014-01-01
Resumen El rastreo de cáncer colorrectal (CCR) cuenta con fuertes evidencias en su favor. Datos preliminares indican que a pesar de ello no se lleva a cabo con la frecuencia adecuada. Se intenta aquí determinar, dentro de un Sistema de Salud que cuenta con los recursos necesarios, los elementos que facilitan o generan barreras para concretar esta práctica preventiva, cuántos individuos lo ponen en práctica y qué predice esta conducta. Se realizó una encuesta telefónica a los afiliados de una Obra Social de empleados de la Universidad de Buenos Aires, de los que 132 completaron el cuestionario (tasa de respuesta 70%). Los elementos considerados facilitadores del rastreo obtuvieron respuestas afirmativas en el 64 a 97%, mientras que los que definían barreras un 11 a 27%. En este último grupo, una categoría diferenciada la constituía el miedo a los efectos adversos: 39%, y el sentimiento de vergüenza relacionado con los procedimientos: 30%. Un 33% de los encuestados tenían hecho un método de rastreo, mayoritariamente de sangre oculta (27), sigmoideoscopía (11) y colonoscopía (20). Una mayoría afirmó que “se haría el procedimiento si el médico se lo recomendara” (95%), o “no se lo haría excepto que su médico se lo aconseje” (87%). Contestar afirmativamente que “los médicos hacen lo mejor para los pacientes” se asoció con haberse hecho un método de rastreo de CCR, OR 1.55 (IC 95%: 1.02-2.37) p: 0.04. El grupo de individuos estudiado parece bien predispuesto para el rastreo del CCR, la recomendación médica sería aquí un determinante prominente para ponerlo en práctica. PMID:19414294
Colonoscopy-induced acute diverticulitis: myth or reality?
Gorgun, Emre; Isik, Ozgen; Sapci, Ipek; Aytac, Erman; Abbas, Maher A; Ozuner, Gokhan; Church, James; Steele, Scott R
2018-07-01
Colonoscopy in patients with diverticulosis can be technically challenging and limited data exist relating to the risk of post-colonoscopy diverticulitis. Our aim was to evaluate the incidence, management, and outcomes of acute diverticulitis following colonoscopy. Study design is retrospective cohort study. Data were gathered by conducting an automated search of the electronic patient database using current procedural terminology and ICD-9 codes. Patients who underwent a colonoscopy from 2003 to 2012 were reviewed to find patients who developed acute diverticulitis within 30 days after colonoscopy. Patient demographics and colonoscopy-related outcomes were documented, which include interval between colonoscopy and diverticulitis, colonoscopy indication, simultaneous colonoscopic interventions, and follow-up after colonoscopy. From 236,377 colonoscopies performed during the study period, 68 patients (mean age 56 years) developed post-colonoscopy diverticulitis (0.029%; 2.9 per 10,000 colonoscopies). Incomplete colonoscopies were more frequent among patients with a history of previous diverticulitis [n = 10 (29%) vs. n = 3 (9%), p = 0.03]. Mean time to develop diverticulitis after colonoscopy was 12 ± 8 days, and 30 (44%) patients required hospitalization. 34 (50%) patients had a history of diverticulitis prior to colonoscopy. Among those patients, 14 underwent colonoscopy with an indication of surveillance for previous disease. When colonoscopy was performed within 6 weeks of a diverticulitis attack, surgical intervention was required more often when compared with colonoscopies performed after 6 weeks of an acute attack [n = 6 (100%) vs. n = 10 (36%), p = 0.006]. 6 (9%) out of 68 patients received emergency surgical treatment. 15 (24%) out of 62 patients who had non-surgical treatment initially underwent an elective sigmoidectomy at a later date. Recurrent diverticulitis developed in 16 (23%) patients after post-colonoscopy diverticulitis. Post-colonoscopy diverticulitis is a rare, but potentially serious complication. Although a rare entity, possibility of this complication should be kept in mind in patients presenting with symptoms after colonoscopy.
Komeda, Yoriaki; Handa, Hisashi; Watanabe, Tomohiro; Nomura, Takanobu; Kitahashi, Misaki; Sakurai, Toshiharu; Okamoto, Ayana; Minami, Tomohiro; Kono, Masashi; Arizumi, Tadaaki; Takenaka, Mamoru; Hagiwara, Satoru; Matsui, Shigenaga; Nishida, Naoshi; Kashida, Hiroshi; Kudo, Masatoshi
2017-01-01
Computer-aided diagnosis (CAD) is becoming a next-generation tool for the diagnosis of human disease. CAD for colon polyps has been suggested as a particularly useful tool for trainee colonoscopists, as the use of a CAD system avoids the complications associated with endoscopic resections. In addition to conventional CAD, a convolutional neural network (CNN) system utilizing artificial intelligence (AI) has been developing rapidly over the past 5 years. We attempted to generate a unique CNN-CAD system with an AI function that studied endoscopic images extracted from movies obtained with colonoscopes used in routine examinations. Here, we report our preliminary results of this novel CNN-CAD system for the diagnosis of colon polyps. A total of 1,200 images from cases of colonoscopy performed between January 2010 and December 2016 at Kindai University Hospital were used. These images were extracted from the video of actual endoscopic examinations. Additional video images from 10 cases of unlearned processes were retrospectively assessed in a pilot study. They were simply diagnosed as either an adenomatous or nonadenomatous polyp. The number of images used by AI to learn to distinguish adenomatous from nonadenomatous was 1,200:600. These images were extracted from the videos of actual endoscopic examinations. The size of each image was adjusted to 256 × 256 pixels. A 10-hold cross-validation was carried out. The accuracy of the 10-hold cross-validation is 0.751, where the accuracy is the ratio of the number of correct answers over the number of all the answers produced by the CNN. The decisions by the CNN were correct in 7 of 10 cases. A CNN-CAD system using routine colonoscopy might be useful for the rapid diagnosis of colorectal polyp classification. Further prospective studies in an in vivo setting are required to confirm the effectiveness of a CNN-CAD system in routine colonoscopy. © 2017 S. Karger AG, Basel.
Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy.
Valdastri, P; Ciuti, G; Verbeni, A; Menciassi, A; Dario, P; Arezzo, A; Morino, M
2012-05-01
Despite being considered the most effective method for colorectal cancer diagnosis, colonoscopy take-up as a mass-screening procedure is limited mainly due to invasiveness, patient discomfort, fear of pain, and the need for sedation. In an effort to mitigate some of the disadvantages associated with colonoscopy, this work provides a preliminary assessment of a novel endoscopic device consisting in a softly tethered capsule for painless colonoscopy under robotic magnetic steering. The proposed platform consists of the endoscopic device, a robotic unit, and a control box. In contrast to the traditional insertion method (i.e., pushing from behind), a "front-wheel" propulsion approach is proposed. A compliant tether connecting the device to an external box is used to provide insufflation, passing a flexible operative tool, enabling lens cleaning, and operating the vision module. To assess the diagnostic and treatment ability of the platform, 12 users were asked to find and remove artificially implanted beads as polyp surrogates in an ex vivo model. In vivo testing consisted of a qualitative study of the platform in pigs, focusing on active locomotion, diagnostic and therapeutic capabilities, safety, and usability. The mean percentage of beads identified by each user during ex vivo trials was 85 ± 11%. All the identified beads were removed successfully using the polypectomy loop. The mean completion time for accomplishing the entire procedure was 678 ± 179 s. No immediate mucosal damage, acute complications such as perforation, or delayed adverse consequences were observed following application of the proposed method in vivo. Use of the proposed platform in ex vivo and preliminary animal studies indicates that it is safe and operates effectively in a manner similar to a standard colonoscope. These studies served to demonstrate the platform's added advantages of reduced size, front-wheel drive strategy, and robotic control over locomotion and orientation.
Khuroo, Mohammad S; Khuroo, Mehnaaz S; Khuroo, Naira S
2010-01-01
There are few published reports of Trichuris dysentery syndrome (TDS) in children. The disease has not been reported in adults. To report the clinical, colonoscopic, and histologic findings of TDS in adults in an endemic area. Case series. Tertiary gastroenterology center. Eighty-four consecutive adult patients with chronic iron deficiency anemia over a 3-year period were investigated. Ten patients had severe Trichuris trichiura infection and received a diagnosis of TDS. Colonoscopy and colonic biopsies. Patients received anthelmintic treatment, and their response was assessed. Ten patients with TDS were studied, including 8 female and 2 male patients with a mean (+/- standard deviation) age of 43 (+/- 15.5) years (range 15-65 years) and a hemoglobin level (+/- standard deviation) of 6.0 +/- 1.5 g/dL (range 4-8 g/dL); the duration (+/- standard deviation) of disease was 2.1 +/- 1.1 years (range 1.5-8.5 years). None of the patients had growth retardation, malnutrition, or immunodeficiency. Abdominal symptoms included abdominal pain, diarrhea, and hematochezia in 1 patient. Nine other patients had no abdominal symptoms. Colonoscopy revealed actively motile T. trichiura worms in large numbers in the right colon in 7 patients, in the ileum in 1, in the left colon in 1, and worms carpeting of the whole colonic mucosa in 1. Associated mucosal changes included petechial lesions, blotchy mucosal hemorrhages, and active mucosal oozing. Biopsy of the colon revealed worm segments with a thick outer cuticle. The posterior segment of the worm contained gravid uterus with numerous characteristic T. trichiura eggs. There was paucity of associated mucosal changes in most of the sections. Similar studies in other endemic areas are lacking. TDS should be considered in all patients in endemic areas with chronic iron deficiency anemia and/or occult blood loss. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Improved adenoma detection with Endocuff Vision: the ADENOMA randomised controlled trial.
Ngu, Wee Sing; Bevan, Roisin; Tsiamoulos, Zacharias P; Bassett, Paul; Hoare, Zoë; Rutter, Matthew D; Clifford, Gayle; Totton, Nicola; Lee, Thomas J; Ramadas, Arvind; Silcock, John G; Painter, John; Neilson, Laura J; Saunders, Brian P; Rees, Colin J
2018-01-23
Low adenoma detection rates (ADR) are linked to increased postcolonoscopy colorectal cancer rates and reduced cancer survival. Devices to enhance mucosal visualisation such as Endocuff Vision (EV) may improve ADR. This multicentre randomised controlled trial compared ADR between EV-assisted colonoscopy (EAC) and standard colonoscopy (SC). Patients referred because of symptoms, surveillance or following a positive faecal occult blood test (FOBt) as part of the Bowel Cancer Screening Programme were recruited from seven hospitals. ADR, mean adenomas per procedure, size and location of adenomas, sessile serrated polyps, EV removal rate, caecal intubation rate, procedural time, patient experience, effect of EV on workload and adverse events were measured. 1772 patients (57% male, mean age 62 years) were recruited over 16 months with 45% recruited through screening. EAC increased ADR globally from 36.2% to 40.9% (P=0.02). The increase was driven by a 10.8% increase in FOBt-positive screening patients (50.9% SC vs 61.7% EAC, P<0.001). EV patients had higher detection of mean adenomas per procedure, sessile serrated polyps, left-sided, diminutive, small adenomas and cancers (cancer 4.1% vs 2.3%, P=0.02). EV removal rate was 4.1%. Median intubation was a minute quicker with EAC (P=0.001), with no difference in caecal intubation rate or withdrawal time. EAC was well tolerated but caused a minor increase in discomfort on anal intubation in patients undergoing colonoscopy with no or minimal sedation. There were no significant EV adverse events. EV significantly improved ADR in bowel cancer screening patients and should be used to improve colonoscopic detection. NCT 02552017, Results; ISRCTN 11821044, Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Iacucci, Marietta; Trovato, Cristina; Daperno, Marco; Akinola, Oluseyi; Greenwald, David; Gross, Seth A; Hoffman, Arthur; Lee, Jeffrey; Lethebe, Brendan C; Lowerison, Mark; Nayor, Jennifer; Neumann, Helmut; Rath, Timo; Sanduleanu, Silvia; Sharma, Prateek; Kiesslich, Ralf; Ghosh, Subrata; Saltzman, John R
2018-03-23
Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. In phase 1, a new simplified endoscopic classification for polyps - Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) - was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp histology before and after training, and univariable/multivariable analysis of the endoscopic features, were performed. In phase 3, the reproducibility of SIMPLE by trainees using different endoscopy platforms was evaluated. Using the SIMPLE classification, the accuracy of experts in predicting polyps was 83 % (95 % confidence interval [CI] 77 % - 88 %) before and 94 % (95 %CI 89 % - 97 %) after training ( P = 0.002). The sensitivity, specificity, positive predictive value, and negative predictive value after training were 97 %, 88 %, 95 %, and 91 %. The interobserver agreement of polyp diagnosis improved from 0.46 (95 %CI 0.30 - 0.64) before to 0.66 (95 %CI 0.48 - 0.82) after training. The trainees demonstrated that the SIMPLE classification is applicable across endoscopy platforms, with similar post-training accuracies for narrow-band imaging NBI classification (0.69; 95 %CI 0.64 - 0.73) and SIMPLE (0.71; 95 %CI 0.67 - 0.75). Using the I-SCAN OE system, the new SIMPLE classification demonstrated a high degree of accuracy for adenoma diagnosis, meeting the ASGE PIVI recommendations. We demonstrated that SIMPLE may be used with either I-SCAN OE or NBI. © Georg Thieme Verlag KG Stuttgart · New York.
Joo, Young-Eun; Karrasch, Thomas; Mühlbauer, Marcus; Allard, Brigitte; Narula, Acharan; Herfarth, Hans H.; Jobin, Christian
2009-01-01
Background The impact of tomato lycopene extract (TLE) on intestinal inflammation is currently unknown. We investigated the effect of TLE on lipopolysaccharide (LPS)-induced innate signaling and experimental colitis. Methodology/Principal Findings Mice were fed a diet containing 0.5 and 2% TLE or isoflavone free control (AIN-76). The therapeutic efficacy of TLE diet was assessed using dextran sulfate sodium (DSS) exposed mice and IL-10−/−;NF-κBEGFP mice, representing an acute and spontaneous chronic colitis model respectively. A mini-endoscope was used to determine the extent of macroscopic mucosal lesions. Murine splenocytes and intestinal epithelial cells were used to determine the in vitro impact of TLE on LPS-induced NF-κB signaling. In vitro, TLE blocked LPS-induced IκBα degradation, RelA translocation, NF-κB transcriptional activity and MIP-2 mRNA accumulation in IEC-18 cells. Moreover, LPS-induced IL-12p40 gene expression was dose-dependently inhibited in TLE-treated splenocytes. Interestingly, DSS-induced acute colitis worsened in TLE-fed NF-κBEGFP mice compared to control diet as measured by weight loss, colonoscopic analysis and histological scores. In contrast, TLE-fed IL-10−/−;NF-κBEGFP mice displayed decreased colonic EGFP expression compared to control diet. IL-6, TNFα, and MCP-1 mRNA expression were increased in the colon of TLE-fed, DSS-exposed NF-κBEGFP mice compared to the control diet. Additionally, caspase-3 activation and TUNEL positive cells were enhanced in TLE diet-fed, DSS-exposed mice as compared to DSS control mice. Conclusions/ Significance These results indicate that TLE prevents LPS-induced proinflammatory gene expression by blocking of NF-κB signaling, but aggravates DSS-induced colitis by enhancing epithelial cell apoptosis. PMID:19234608
Schmidt, Arthur; Beyna, Torsten; Schumacher, Brigitte; Meining, Alexander; Richter-Schrag, Hans-Juergen; Messmann, Helmut; Neuhaus, Horst; Albers, David; Birk, Michael; Thimme, Robert; Probst, Andreas; Faehndrich, Martin; Frieling, Thomas; Goetz, Martin; Riecken, Bettina; Caca, Karel
2017-08-10
Endoscopic full-thickness resection (EFTR) is a novel treatment of colorectal lesions not amenable to conventional endoscopic resection. The aim of this prospective multicentre study was to assess the efficacy and safety of the full-thickness resection device. 181 patients were recruited in 9 centres with the indication of difficult adenomas (non-lifting and/or at difficult locations), early cancers and subepithelial tumours (SET). Primary endpoint was complete en bloc and R0 resection. EFTR was technically successful in 89.5%, R0 resection rate was 76.9%. In 127 patients with difficult adenomas and benign histology, R0 resection rate was 77.7%. In 14 cases, lesions harboured unsuspected cancer, another 15 lesions were primarily known as cancers. Of these 29 cases, R0 resection was achieved in 72.4%; 8 further cases had deep submucosal infiltration >1000 µm. Therefore, curative resection could only be achieved in 13/29 (44.8%). In the subgroup with SET (n=23), R0 resection rate was 87.0%. In general, R0 resection rate was higher with lesions ≤2 cm vs >2 cm (81.2% vs 58.1%, p=0.0038). Adverse event rate was 9.9% with a 2.2% rate of emergency surgery. Three-month follow-up was available from 154 cases and recurrent/residual tumour was evident in 15.3%. EFTR has a reasonable technical efficacy especially in lesions ≤2 cm with acceptable complication rates. Curative resection rate for early cancers was too low to recommend its primary use in this indication. Further comparative studies have to show the clinical value and long-term outcome of EFTR in benign colorectal lesions. NCT02362126; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Prophylactic Antibiotics for Endoscopy-Associated Peritonitis in Peritoneal Dialysis Patients
Wu, Hsin-Hsu; Li, I-Jung; Weng, Cheng-Hao; Lee, Cheng-Chia; Chen, Yung-Chang; Chang, Ming-Yang; Fang, Ji-Tseng; Hung, Cheng-Chieh; Yang, Chih-Wei; Tian, Ya-Chung
2013-01-01
Introduction Continuous ambulatory peritoneal dialysis (CAPD) peritonitis may develop after endoscopic procedures, and the benefit of prophylactic antibiotics is unclear. In the present study, we investigated whether prophylactic antibiotics reduce the incidence of peritonitis in these patients. Patients and methods We retrospectively reviewed all endoscopic procedures, including esophagogastroduodenoscopy (EGD), colonoscopy, sigmoidoscopy, cystoscopy, hysteroscopy, and hysteroscopy-assisted intrauterine device (IUD) implantation/removal, performed in CAPD patients at Chang Gung Memorial Hospital, Taiwan, between February 2001 and February 2012. Results Four hundred and thirty-three patients were enrolled, and 125 endoscopies were performed in 45 patients. Eight (6.4%) peritonitis episodes developed after the examination. Antibiotics were used in 26 procedures, and none of the patients had peritonitis (0% vs. 8.1% without antibiotic use; p = 0.20). The peritonitis rate was significantly higher in the non-EGD group than in the EGD group (15.9% [7/44] vs. 1.2% [1/81]; p<0.005). Antibiotic use prior to non-EGD examinations significantly reduced the endoscopy-associated peritonitis rate compared to that without antibiotic use (0% [0/16] vs. 25% [7/28]; p<0.05). Peritonitis only occurred if invasive procedures were performed, such as biopsy, polypectomy, or IUD implantation, (noninvasive procedures, 0% [0/20] vs. invasive procedures, 30.4% [7/23]; p<0.05). No peritonitis was noted if antibiotics were used prior to examination with invasive procedures (0% [0/10] vs. 53.8% [7/13] without antibiotic use; p<0.05). Although not statistically significant, antibiotics may play a role in preventing gynecologic procedure-related peritonitis (antibiotics, 0% [0/4] vs. no antibiotics, 55.6% [5/9]; p = 0.10). Conclusion Antibiotic prophylaxis significantly reduced endoscopy-associated PD peritonitis in the non-EGD group. Endoscopically assisted invasive procedures, such as biopsy, polypectomy, IUD implantation/removal, and dilatation and curettage (D&C), pose a high risk for peritonitis. Prophylactic antibiotics for peritonitis prevention may be required in colonoscopic procedures and gynecologic procedures. PMID:23936514
Barrow, Emma; Evans, D Gareth; McMahon, Ray; Hill, James; Byers, Richard
2011-03-01
Lynch Syndrome is caused by mutations in DNA mismatch repair (MMR) genes. Mutation carrier identification is facilitated by immunohistochemical detection of the MMR proteins MHL1 and MSH2 in tumour tissue and is desirable as colonoscopic screening reduces mortality. However, protein detection by conventional immunohistochemistry (IHC) is subjective, and quantitative techniques are required. Quantum dots (QDs) are novel fluorescent labels that enable quantitative multiplex staining. This study compared their use with quantitative 3,3'-diaminobenzidine (DAB) IHC for the diagnosis of Lynch Syndrome. Tumour sections from 36 mutation carriers and six controls were obtained. These were stained with DAB on an automated platform using antibodies against MLH1 and MSH2. Multiplex QD immunofluorescent staining of the sections was performed using antibodies against MLH1, MSH2 and smooth muscle actin (SMA). Multispectral analysis of the slides was performed. The staining intensity of DAB and QDs was measured in multiple colonic crypts, and the mean intensity scores calculated. Receiver operating characteristic (ROC) curves of staining performance for the identification of mutation carriers were evaluated. For quantitative DAB IHC, the area under the MLH1 ROC curve was 0.872 (95% CI 0.763 to 0.981), and the area under the MSH2 ROC curve was 0.832 (95% CI 0.704 to 0.960). For quantitative QD IHC, the area under the MLH1 ROC curve was 0.812 (95% CI 0.681 to 0.943), and the area under the MSH2 ROC curve was 0.598 (95% CI 0.418 to 0.777). Despite the advantage of QD staining to enable several markers to be measured simultaneously, it is of lower utility than DAB IHC for the identification of MMR mutation carriers. Automated DAB IHC staining and quantitative slide analysis may enable high-throughput IHC.
Hsieh, Yu-Hsi; Tseng, Chih-Wei; Hu, Chi-Tan; Koo, Malcolm; Leung, Felix W
2017-07-01
Adenoma detection rate (ADR), defined as the proportion of patients with at least one adenoma of any size, is a quality indicator. We tested the hypothesis that water exchange (WE) improves ADR but water immersion (WI) has no adverse effect on ADR compared with air insufflation (AI). A prospective study was conducted at the Dalin Tzu Chi Hospital in southern Taiwan and the Hualien Tzu Chi Hospital in eastern Taiwan on patients randomly assigned to WE, WI, or AI with stratification by the 3 study colonoscopists. The primary outcome was ADR. From July 2013 to December 2015, 651 patients were recruited and randomized into 3 groups with a 1:1:1 ratio (217 patients per group). Overall, ADR met quality standards: WE 49.8% (95% CI, 43.2%-56.4%), AI 37.8% (95% CI, 31.6%-44.4%), and WI 40.6% (95% CI, 34.2%-47.2%). Compared with AI, WE significantly increased ADR (P = .016). There was no difference between WI and WE. ADRs of WI and AI were comparable. Compared with AI, WE confirmed a longer insertion time, higher cleanliness score, but similar adenoma per positive colonoscopy (APPC) and withdrawal time with polypectomy. Subgroup analysis found WE significantly increased ADR in propofol-sedated patients. Multivariate generalized linear mixed model analysis revealed that age ≥50 years, WE (vs AI), colonoscopy indication, no previous history of colonoscopy, and withdrawal time >8 minutes were significant predictors of increased ADR. Confirmation of prior reports showing WE, but not WI, increased ADR further strengthened the validity of our observations. WE significantly increased ADR in propofol-sedated patients. The outcome differences justify assessment of the role of WE in colorectal cancer prevention. Similar APPC and withdrawal times suggest that adequate inspection was performed on colonoscope withdrawal in each of the study arms. (Clinical trial registration number: NCT01894191.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. All rights reserved.
Garofalo, Fabio; Abouzahr, Omar; Atlas, Henri; Denis, Ronald; Garneau, Pierre; Huynh, Hai; Pescarus, Radu
2018-01-01
Various reconstructions of the gastro-intestinal tract have been described in the past after distal gastrectomy. Among these, a Billroth II (BII) anastomosis can be performed with the addition of the Omega entero-enterostomy that may theoretically reduce the alkaline reflux. Given the significant complications associated with this procedure such as biliary reflux, marginal ulceration, and afferent loop syndrome, a revision into a Roux-en-Y anatomy is generally recommended. A 73-year-old healthy male was referred to our foregut surgery service for treatment of severe biliary gastritis. The patient previously underwent an open distal gastrectomy with a BII reconstruction followed by a Braun-type entero-enterostomy 6 months later. His main complaint was worsening daily biliary reflux with constant regurgitations, which were non-responsive to medical treatment. The preoperative endoscopy confirmed the diagnosis of severe biliary gastritis secondary to alkaline reflux. The distance between the gastro-jejunostomy and the Braun anastomosis was also measured with a pediatric colonoscope and the length of the efferent limb was estimated to be 80 cm. Identification of the afferent and efferent limb was complicated by the patient's incomplete intestinal malrotation with the angle of Treitz being present in the right hypochondrium. Intra-operative gastroscopy enabled visualization of the jejuno-jejunostomy and ensured correct interpretation of the anatomy. Subsequently, resection of the afferent limb completed the revision into a Roux-en-Y anatomy. The patient recovered well after the surgery and was discharged home on post-operative day 2. At 6 months follow-up, the patient's reflux symptoms have completely disappeared. BII reconstruction with or without Braun entero-enterostomy is a classic historical option following distal gastrectomy. Surgical revision of a BII into a Roux-en-Y anatomy is a good solution for severe biliary reflux and other long-term complications. Intra-operative endoscopy is a great adjunct to laparoscopic exploration in case of complex surgical procedures.
Multitarget stool DNA testing for colorectal-cancer screening.
Imperiale, Thomas F; Ransohoff, David F; Itzkowitz, Steven H; Levin, Theodore R; Lavin, Philip; Lidgard, Graham P; Ahlquist, David A; Berger, Barry M
2014-04-03
An accurate, noninvasive test could improve the effectiveness of colorectal-cancer screening. We compared a noninvasive, multitarget stool DNA test with a fecal immunochemical test (FIT) in persons at average risk for colorectal cancer. The DNA test includes quantitative molecular assays for KRAS mutations, aberrant NDRG4 and BMP3 methylation, and β-actin, plus a hemoglobin immunoassay. Results were generated with the use of a logistic-regression algorithm, with values of 183 or more considered to be positive. FIT values of more than 100 ng of hemoglobin per milliliter of buffer were considered to be positive. Tests were processed independently of colonoscopic findings. Of the 9989 participants who could be evaluated, 65 (0.7%) had colorectal cancer and 757 (7.6%) had advanced precancerous lesions (advanced adenomas or sessile serrated polyps measuring ≥1 cm in the greatest dimension) on colonoscopy. The sensitivity for detecting colorectal cancer was 92.3% with DNA testing and 73.8% with FIT (P=0.002). The sensitivity for detecting advanced precancerous lesions was 42.4% with DNA testing and 23.8% with FIT (P<0.001). The rate of detection of polyps with high-grade dysplasia was 69.2% with DNA testing and 46.2% with FIT (P=0.004); the rates of detection of serrated sessile polyps measuring 1 cm or more were 42.4% and 5.1%, respectively (P<0.001). Specificities with DNA testing and FIT were 86.6% and 94.9%, respectively, among participants with nonadvanced or negative findings (P<0.001) and 89.8% and 96.4%, respectively, among those with negative results on colonoscopy (P<0.001). The numbers of persons who would need to be screened to detect one cancer were 154 with colonoscopy, 166 with DNA testing, and 208 with FIT. In asymptomatic persons at average risk for colorectal cancer, multitarget stool DNA testing detected significantly more cancers than did FIT but had more false positive results. (Funded by Exact Sciences; ClinicalTrials.gov number, NCT01397747.).
Colorectal cancer in patients with type 2 diabetes mellitus: a single-center experience.
Sinagra, E; Guarnotta, V; Raimondo, D; Mocciaro, F; Dolcimascolo, S; Rizzolo, C A; Puccia, F; Maltese, N; Citarrella, R; Messina, M; Spada, M; Tomasello, G; Cappello, F; Leone, A; Rossi, F; Di Mitri, R; Morreale, G C; Marasà, S; Midiri, M; Midiri, F; Sinagra, D
2017-01-01
Type 2 diabetes mellitus (T2DM) is associated with an increased risk of colorectal cancer (CRC). The aim of the study is to evaluate the prevalence of CRC in a cohort of Caucasian patients with T2DM and the association with other variables previously known to be related with increased risk of CRC. We retrospectively evaluated the data of 741 consecutive Caucasian patients with T2DM who underwent colonoscopic screening in our tertiary referral center. A control cohort of 333 patients with thyroid disease was selected to evaluate the difference in the incidence of CRC. At a median follow-up of 132.5 months (range 33.3-175.7), 67 cases of cancer (prevalence 9%) occurred; among these, 14 cases of CRC were reported (prevalence 1.88%) among the diabetic patients, while only two case (one of these was a CRC) (overall prevalence 0.006%, prevalence of CRC 0.003%) occurred in the control group; the difference between the prevalence of CRC was statistically significant (chi-square 4.21, p=0.04). The median duration of T2DM to CRC diagnosis was 168 months (range 12-768). At the univariate analysis, older age (p=0.001, r 0.138) and diabetes duration (p=0.001, r 0.138) were related to higher risk of cancer, while metformin seems to be protective towards cancer (p=0.07, r -0.098). In the subset of patients with CRC, the age (RR = 2.25; 95% CI: 0.30 - 17.31; p less than 0.001), the diabetes duration (RR = 1.93; 95% CI: 0.25 14.77; p = 0.001) and the sulphonylureas treatment (RR = 2.33; 95% CI: 0.78 7.38; p = 0.007) were independently correlated with CRC. In our study, the prevalence of CRC in the cohort of patients with T2DM was higher compared to that from the National Tumor Register in 2010 (0.5%). Furthermore, we could speculate that sulphonylureas may play a role in CRC carcinogenesis impairing the physiological insulin secretion.
Colorectal Cancer Screening Based on Age and Gender
Wong, Martin C.S.; Ching, Jessica Y.L.; Chan, Victor C.W.; Lam, Thomas Y.T.; Luk, Arthur K.C.; Wong, Sunny H.; Ng, Siew C.; Ng, Simon S.M.; Wu, Justin C.Y.; Chan, Francis K.L.; Sung, Joseph J.Y.
2016-01-01
Abstract We evaluated whether age- and gender-based colorectal cancer screening is cost-effective. Recent studies in the United States identified age and gender as 2 important variables predicting advanced proximal neoplasia, and that women aged <60 to 70 years were more suited for sigmoidoscopy screening due to their low risk of proximal neoplasia. Yet, quantitative assessment of the incremental benefits, risks, and cost remains to be performed. Primary care screening practice (2008–2015). A Markov modeling was constructed using data from a screening cohort. The following strategies were compared according to the Incremental Cost Effectiveness Ratio (ICER) for 1 life-year saved: flexible sigmoidoscopy (FS) 5 yearly; colonoscopy 10 yearly; FS for each woman at 50- and 55-year old followed by colonoscopy at 60- and 70-year old; FS for each woman at 50-, 55-, 60-, and 65-year old followed by colonoscopy at 70-year old; FS for each woman at 50-, 55-, 60-, 65-, and 70-year old. All male subjects received colonoscopy at 50-, 60-, and 70-year old under strategies 3 to 5. From a hypothetical population of 100,000 asymptomatic subjects, strategy 2 could save the largest number of life-years (4226 vs 2268 to 3841 by other strategies). When compared with no screening, strategy 5 had the lowest ICER (US$42,515), followed by strategy 3 (US$43,517), strategy 2 (US$43,739), strategy 4 (US$47,710), and strategy 1 (US$56,510). Strategy 2 leads to the highest number of bleeding and perforations, and required a prohibitive number of colonoscopy procedures. Strategy 5 remains the most cost-effective when assessed with a wide range of deterministic sensitivity analyses around the base case. From the cost effectiveness analysis, FS for women and colonoscopy for men represent an economically favorable screening strategy. These findings could inform physicians and policy-makers in triaging eligible subjects for risk-based screening, especially in countries with limited colonoscopic resources. Future research should study the acceptability, feasibility, and feasibility of this risk-based strategy in different populations. PMID:26962772
Repici, A; Pagano, N; Rando, G; Carlino, A; Vitetta, E; Ferrara, E; Strangio, G; Zullo, A; Hassan, C
2013-07-01
Benign colorectal strictures are treated conventionally by endoscopic dilation. Experience using SEMS for benign colonic strictures is limited, and outcomes to date have been disappointing. Refractory colorectal strictures remain challenging to be treated with surgery. Polydioxanone-based stent are biodegradable (BD) stent CE approved for esophageal strictures. This study was designed to investigate retrospectively the safety and the efficacy of these stents for the management of strictures refractory to multiple sessions of dilation. Patients with postsurgical benign strictures located within 20 cm from anal verge, refractory to mechanical or pneumatic dilation (at least 3 sessions) were included in this analysis. Clinical success was defined as the absence of occlusive symptoms and the ability to pass through the stricture with a regular size colonoscope. All patients were predilated before stent placement. Stents were released under fluoroscopic control. All patients were under stool softeners for 3 months. Follow-up was scheduled with endoscopic and fluoroscopic controls within 90 days from stent deployment and afterwards by telephone interview and/or ambulatory consultation. Eleven patients (7 males, mean age 62.3 ± 8.5 years) were included. Technical success was achieved in all the patients. Stent migration was observed in four patients within the first 2 weeks after stent placement. Stent migration was followed by recurrence of stricture and obstructive symptoms in all the cases. Among the seven patients who completed the process of stent biodegradation, five of them had complete resolution of the stricture and relief of symptoms. Two of 11 patients required surgical treatment during the follow-up period (mean 19.8 (range 42-15) months). The overall success rate of the BD stent was 45 %. This retrospective analysis of a limited number of patients demonstrated that nondedicated esophageal BD stents are associated with high risk of migration and clinical success in less than 50 % of patients. Dedicated stents with large diameter and antimigration findings could potentially improve the outcome of patients with refractory benign colorectal strictures.
Lee, Tsung-Chun; Wang, Hsiu-Po; Chiu, Han-Mo; Lien, Wan-Ching; Chen, Mei-Jyh; Yu, Linda C H; Sun, Chia-Tung; Lin, Jaw-Town; Wu, Ming-Shiang
2010-01-01
Ischemic colitis (IC) spans a broad spectrum from self-limiting illness to intestinal gangrene and mortality. Prognostic factors specifically for nonpostoperative IC were not fully characterized. We aim to focus on nonpostoperative IC in patients with renal dysfunction and try to identify prognostic factors for adverse outcomes. We conducted a retrospective analysis at a university-affiliated tertiary medical center in Taiwan. From January 2003 to August 2008, 25 men and 52 women (mean age: 66 y) had colonoscopic biopsy-proven IC without prior culprit surgery. We estimated glomerular filtration rate with simplified Modification of Diet in Renal Disease equation. Nine patients with glomerular filtration rate below 30 mL per minute per 1.73 m were classified as renal dysfunction group (including 7 dialysis patients). Adverse outcomes were defined as need for surgery and mortality. Predictors for adverse outcomes were captured by univariate and multivariate analysis. Research ethical committee approved the study protocol. Patients with renal dysfunction more often had: diabetes mellitus (56% vs. 16%, P=0.02), prolonged symptoms (6.8 d vs. 3.5 d, P=0.01), lower hemoglobin (11.1 g/dL vs. 13.4 g/dL, P=0.01), and more often right colonic involvement (56% vs. 19%, P=0.03). Renal dysfunction patients also had longer hospitalization days (median 15 d vs. 4 d, P=0.045). However, there was no statistical significance in the rate of either surgery or mortality between these 2 groups (P>0.05). Univariate analysis showed that renal dysfunction, sex, emergency department referral, presentation with abdominal pain were significant for adverse outcome (P<0.1). Multivariate analysis revealed that male sex conveyed 9.5-fold risk (P=0.01) and renal dysfunction conveyed 8.5-fold risk (P=0.03) for adverse outcomes. Nonpostoperative IC patients with concurrent renal dysfunction had distinct clinical profiles. Multivariate analysis showed that male patients had 9.5-fold and renal dysfunction patients had 8.5-fold increased risk for adverse outcomes. Although IC is often self-limited, our data warrants special attention and aggressive therapy in treating these patients.
Nagata, Naoyoshi; Sakamoto, Kayo; Arai, Tomohiro; Niikura, Ryota; Shimbo, Takuro; Shinozaki, Masafumi; Noda, Mitsuhiko; Uemura, Naomi
2014-10-01
Several factors affect the risk for longer cecal insertion time. The aim of this study was to identify the predictors of longer insertion time and to evaluate the effect of visceral fat measured by CT. This is a retrospective observational study. Outpatients for colorectal cancer screening who underwent colonoscopies and CT were enrolled. Computed tomography was performed in individuals who requested cancer screening and in those with GI bleeding. Information on obesity indices (BMI, visceral adipose tissue, and subcutaneous adipose tissue area), constipation score, history of abdominal surgery, poor preparation, fellow involvement, diverticulosis, patient discomfort, and the amount of sedation used was collected. The cecal insertion rate was 95.2% (899/944), and 899 patients were analyzed. Multiple regression analysis showed that female sex, lower BMI, lower visceral adipose tissue area, lower subcutaneous adipose tissue area, higher constipation score, history of surgery, poor bowel preparation, and fellow involvement were independently associated with longer insertion time. When obesity indices were considered simultaneously, smaller subcutaneous adipose tissue area (p = 0.038), but not lower BMI (p = 0.802) or smaller visceral adipose tissue area (p = 0.856), was associated with longer insertion time; the other aforementioned factors remained associated with longer insertion time. In the subanalysis of normal-weight patients (BMI <25 kg/m), a smaller subcutaneous adipose tissue area (p = 0.002), but not a lower BMI (p = 0.782), was independently associated with a longer insertion time. Longer insertion time had a positive correlation with a higher patient discomfort score (ρ = 0.51, p < 0.001) and a greater amount of midazolam use (ρ = 0.32, p < 0.001). This single-center retrospective study includes a potential selection bias. In addition to BMI and intra-abdominal fat, female sex, constipation, history of abdominal surgery, poor preparation, and fellow involvement were predictors of longer cecal insertion time. Among the obesity indices, high subcutaneous fat accumulation was the best predictive factor for easier passage of the colonoscope, even when body weight was normal.
Leung, Joseph; Mann, Surinder; Siao-Salera, Rodelei; Ransibrahmanakul, Kanat; Lim, Brian; Canete, Wilhelmina; Samson, Laramie; Gutierrez, Rebeck; Leung, Felix W
2011-01-01
Sedation for colonoscopy discomfort imposes a recovery-time burden on patients. The water method permitted 52% of patients accepting on-demand sedation to complete colonoscopy without sedation. On-site and at-home recovery times were not reported. To confirm the beneficial effect of the water method and document the patient recovery-time burden. Randomized, controlled trial, with single-blinded, intent-to-treat analysis. Veterans Affairs outpatient endoscopy unit. This study involved veterans accepting on-demand sedation for screening and surveillance colonoscopy. Air versus water method for colonoscope insertion. Proportion of patients completing colonoscopy without sedation, cecal intubation rate, medication requirement, maximum discomfort (0 = none, 10 = severe), procedure-related and patient-related outcomes. One hundred veterans were randomized to the air (n = 50) or water (n = 50) method. The proportions of patients who could complete colonoscopy without sedation in the water group (78%) and the air group (54%) were significantly different (P = .011, Fisher exact test), but the cecal intubation rate was similar (100% in both groups). Secondary analysis (data as Mean [SD]) shows that the water method produced a reduction in medication requirement: fentanyl, 12.5 (26.8) μg versus 24.0 (30.7) μg; midazolam, 0.5 (1.1) mg versus 0.94 (1.20) mg; maximum discomfort, 2.3 (1.7) versus 4.9 (2.0); recovery time on site, 8.4 (6.8) versus 12.3 (9.4) minutes; and recovery time at home, 4.5 (9.2) versus 10.9 (14.0) hours (P = .049; P = .06; P = .0012; P = .0199; and P = .0048, respectively, t test). Single Veterans Affairs site, predominantly male population, unblinded examiners. This randomized, controlled trial confirms the reported beneficial effects of the water method. The combination of the water method with on-demand sedation minimizes the patient recovery-time burden. ( NCT00920751.). Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Taylor, Stuart A; Charman, Susan C; Lefere, Philippe; McFarland, Elizabeth G; Paulson, Erik K; Yee, Judy; Aslam, Rizwan; Barlow, John M; Gupta, Arun; Kim, David H; Miller, Chad M; Halligan, Steve
2008-02-01
To prospectively compare the diagnostic performance and time efficiency of both second and concurrent computer-aided detection (CAD) reading paradigms for retrospectively obtained computed tomographic (CT) colonography data sets by using consensus reading (three radiologists) of colonoscopic findings as a reference standard. Ethical permission, HIPAA compliance (for U.S. institutions), and patient consent were obtained from all institutions for use of CT colonography data sets in this study. Ten radiologists each read 25 CT colonography data sets (12 men, 13 women; mean age, 61 years) containing 69 polyps (28 were 1-5 mm, 41 were >or=6 mm) by using workstations integrated with CAD software. Reading was randomized to either "second read" CAD (applied only after initial unassisted assessment) or "concurrent read" CAD (applied at the start of assessment). Data sets were reread 6 weeks later by using the opposing paradigm. Polyp sensitivity and reading times were compared by using multilevel logistic and linear regression, respectively. Receiver operating characteristic (ROC) curves were generated. Compared with the unassisted read, odds of improved polyp (>or=6 mm) detection were 1.5 (95% confidence interval [CI]: 1.0, 2.2) and 1.3 (95% CI: 0.9, 1.9) by using CAD as second and concurrent reader, respectively. Detection odds by using CAD concurrently were 0.87 (95% CI: 0.59, 1.3) and 0.76 (95% CI: 0.57, 1.01) those of second read CAD, excluding and including polyps 1-5 mm, respectively. The concurrent read took 2.9 minutes (95% CI: -3.8, -1.9) less than did second read. The mean areas under the ROC curve (95% CI) for the unassisted read, second read CAD, and concurrent read CAD were 0.83 (95% CI: 0.78, 0.87), 0.86 (95% CI: 0.82, 0.90), and 0.88 (95% CI: 0.83, 0.92), respectively. CAD is more time efficient when used concurrently than when used as a second reader, with similar sensitivity for polyps 6 mm or larger. However, use of second read CAD maximizes sensitivity, particularly for smaller lesions. (c) RSNA, 2007.
Park, Jin-Seok; Kim, Min Su; Kim, HyungKil; Kim, Shin Il; Shin, Chun Ho; Lee, Hyun Jung; Lee, Won Seop; Moon, Soyoung
2016-06-17
High-quality bowel preparation is necessary for colonoscopy. A few studies have been conducted to investigate improvement in bowel preparation quality through patient education. However, the effect of patient education on bowel preparation has not been well studied. A randomized and prospective study was conducted. All patients received regular instruction for bowel preparation during a pre-colonoscopy visit. Those scheduled for colonoscopy were randomly assigned to view an educational video instruction (video group) on the day before the colonoscopy, or to a non-video (control) group. Qualities of bowel preparation using the Ottawa Bowel Preparation Quality scale (Ottawa score) were compared between the video and non-video groups. In addition, factors associated with poor bowel preparation were investigated. A total of 502 patients were randomized, 250 to the video group and 252 to the non-video group. The video group exhibited better bowel preparation (mean Ottawa total score: 3.03 ± 1.9) than the non-video group (4.21 ± 1.9; P < 0.001) and had good bowel preparation for colonoscopy (total Ottawa score <6: 91.6 % vs. 78.5 %; P < 0.001). Multivariate analysis revealed that males (odds ratio [OR] = 1.95, P = 0.029), diabetes mellitus patients (OR = 2.79, P = 0.021), and non-use of visual aids (OR = 3.09, P < 0.001) were associated with poor bowel preparation. In the comparison of the colonoscopic outcomes between groups, the polyp detection rate was not significantly different between video group and non-video group (48/250, 19.2 % vs. 48/252, 19.0 %; P = 0.963), but insertion time was significantly short in video group (5.5 ± 3.2 min) than non-video group (6.1 ± 3.7 min; P = 0.043). The addition of an educational video could improve the quality of bowel preparation in comparison with standard preparation method. Clinical Research Information Service KCT0001836 . The date of registration: March, 08(th), 2016, Retrospectively registered.
A critical evaluation and a search for the ideal colonoscopic preparation.
Arora, Manish; Senadhi, Viplove; Arora, Deepika; Weinstock, Joyce; Dubin, Ethan; Okolo, Patrick I; Dutta, Sudhir K
2013-04-01
The aim of this study was to evaluate the efficacy of various bowel preparations in accomplishing colonic cleansing for optimal mucosal visualization during colonoscopy. The study included a cohort of 980 patients who underwent colonoscopy at our endoscopy center within the last 3 years. All of the study patients were subdivided into four groups. Each group included 245 patients, all receiving a different type of bowel preparation. The bowel preparations used in this study included: magnesium citrate (Group I), a combination of oral sodium phosphate (fleets) and powder PEG-3350 (Group II), powder polyethylene glycol-3350 (PEG-3350 powder for Group III), and oral sodium phosphate (fleets for Group IV). A Colon Prep Score (CPS) was devised to compare the quality of the different bowel preparations used. The colonoscopy results from all of these patients were tabulated and analyzed statistically and expressed as mean ± 1 standard deviation. Statistical analysis was performed using a one way ANOVA with Holm-Sidak method for intergroup analysis. Group I patients received magnesium citrate and had a mean CPS ± 1 SD of 3.11 ± 0.91. Group II patients (fleets and powder PEG-3350 combination) achieved a CPS of 3.37 ± 1.16. The patients in Group III (powder PEG-3350) actually showed the highest mean CPS of 3.44 ± 1.12. Group IV patients who used oral sodium phosphate alone reached a mean CPS of 3.23 ± 1.01. Group III patients (powder PEG-3350 only) demonstrated a statistically higher CPS (P<0.0006) in colon cleansing as compared to Group I patients (magnesium citrate). Similarly, Group II patients (oral sodium phosphate and powder PEG-3350 combination) also showed improved colon cleansing statistically (P<0.006) as compared to Group I patients (magnesium citrate). Overall, all four colon preparations achieved an average CPS greater than 3.0 indicating clinically adequate colonic cleansing. However, powder PEG-3350 alone and in combination with oral sodium phosphate was observed to be statistically superior to magnesium citrate, when used for colon preparation for colonoscopy. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
2011-01-01
Background Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. Methods A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Results Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). Conclusions The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required. PMID:21967345
Forte, Lindy; Shum, Cynthia
2011-10-03
Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required.
Snowsill, Tristan; Huxley, Nicola; Hoyle, Martin; Jones-Hughes, Tracey; Coelho, Helen; Cooper, Chris; Frayling, Ian; Hyde, Chris
2015-04-25
Lynch syndrome is an autosomal dominant cancer predisposition syndrome caused by mutations in the DNA mismatch repair genes MLH1, MSH2, MSH6 and PMS2. Individuals with Lynch syndrome have an increased risk of colorectal cancer, endometrial cancer, ovarian and other cancers. Lynch syndrome remains underdiagnosed in the UK. Reflex testing for Lynch syndrome in early-onset colorectal cancer patients is proposed as a method to identify more families affected by Lynch syndrome and offer surveillance to reduce cancer risks, although cost-effectiveness is viewed as a barrier to implementation. The objective of this project was to estimate the cost-utility of strategies to identify Lynch syndrome in individuals with early-onset colorectal cancer in the NHS. A decision analytic model was developed which simulated diagnostic and long-term outcomes over a lifetime horizon for colorectal cancer patients with and without Lynch syndrome and for relatives of those patients. Nine diagnostic strategies were modelled which included microsatellite instability (MSI) testing, immunohistochemistry (IHC), BRAF mutation testing (methylation testing in a scenario analysis), diagnostic mutation testing and Amsterdam II criteria. Biennial colonoscopic surveillance was included for individuals diagnosed with Lynch syndrome and accepting surveillance. Prophylactic hysterectomy with bilateral salpingo-oophorectomy (H-BSO) was similarly included for women diagnosed with Lynch syndrome. Costs from NHS and Personal Social Services perspective and quality-adjusted life years (QALYs) were estimated and discounted at 3.5% per annum. All strategies included for the identification of Lynch syndrome were cost-effective versus no testing. The strategy with the greatest net health benefit was MSI followed by BRAF followed by diagnostic genetic testing, costing £5,491 per QALY gained over no testing. The effect of prophylactic H-BSO on health-related quality of life (HRQoL) is uncertain and could outweigh the health benefits of testing, resulting in overall QALY loss. Reflex testing for Lynch syndrome in early-onset colorectal cancer patients is predicted to be a cost-effective use of limited financial resources in England and Wales. Research is recommended into the cost-effectiveness of reflex testing for Lynch syndrome in other associated cancers and into the impact of prophylactic H-BSO on HRQoL.
Ingrand, Isabelle; Defossez, Gautier; Richer, Jean-Pierre; Tougeron, David; Palierne, Nicolas; Letard, Jean-Christophe; Beauchant, Michel; Ingrand, Pierre
2016-08-01
Colonoscopic screening is recommended for first-degree relatives of patients diagnosed with colorectal cancer (CRC) or colorectal adenomatous polyps (CAP) before the age of 60 years. This has the potential to reduce CRC-related morbidity and mortality, but uptake is currently inadequate. The aim of the study was to compare the effectiveness of standard information versus a nurse-led tailored intervention designed to promote uptake of colonoscopy screening by siblings of CRC or CAP patients. A randomized controlled trial was conducted. Digestive surgeons and gastroenterologists recruited index patients who developed CRC or CAP before the age of 60 years. All index patients received standard screening information for their siblings, in keeping with current guidelines. Centrally computerized randomization of index patients resulted in allocating all their siblings to the same group, intervention or control. The tailored intervention targeted the index patient first, to help them convey information to their siblings. The nurse then provided the siblings with tailored information based on their answers to a self-questionnaire which explored health behaviors, derived from psychosocial models of prevention. Then the siblings were given a personalized information leaflet to hand to their regular physician. The primary endpoint was the rate of documented colonoscopy performed in siblings within 1 year after diagnosis of the index patient. The intent-to-treat analysis included siblings who refused to participate in the study. Statistical analysis was adjusted for intrafamilial correlation. A total of 304 siblings of 125 index patients were included: 160 in the intervention group and 144 in the control group. The rate of colonoscopy uptake among siblings was 56.3% in the intervention group and 35.4% in the control group (P = 0.0027). The respective rates after exclusion of refusals were 69.2% and 37.0% (P < 0.0001). More lesions were detected in the intervention group (1 invasive cancer and 11 advanced adenomas vs 5 advanced adenomas; P = 0.022). This study demonstrates the effectiveness of a nurse-led tailored intervention designed to promote colonoscopy screening uptake by siblings of patients diagnosed with CRC or CAP before age 60 years. Such tailored interventions that also involve physicians should help to reduce CRC-related mortality.
Hull, Mark A; Sandell, Anna C; Montgomery, Alan A; Logan, Richard F A; Clifford, Gayle M; Rees, Colin J; Loadman, Paul M; Whitham, Diane
2013-07-29
The naturally-occurring omega (ω)-3 polyunsaturated fatty acid (PUFA) eicosapentaenoic acid (EPA) reduces colorectal adenoma (polyp) number and size in patients with familial adenomatous polyposis. The safety profile and potential cardiovascular benefits associated with ω-3 PUFAs make EPA a strong candidate for colorectal cancer (CRC) chemoprevention, alone or in combination with aspirin, which itself has recognized anti-CRC activity. Colorectal adenoma number and size are recognized as biomarkers of future CRC risk and are established as surrogate end-points in CRC chemoprevention trials. The seAFOod Polyp Prevention Trial is a randomized, double-blind, placebo-controlled, 2×2 factorial 'efficacy' study, which will determine whether EPA prevents colorectal adenomas, either alone or in combination with aspirin. Participants are 55-73 year-old patients, who have been identified as 'high risk' (detection of ≥5 small adenomas or ≥3 adenomas with at least one being ≥10 mm in diameter) at screening colonoscopy in the English Bowel Cancer Screening Programme (BCSP). Exclusion criteria include the need for more than one repeat endoscopy within the three-month BCSP screening period, malignant change in an adenoma, regular use of aspirin or non-aspirin non-steroidal anti-inflammatory drugs, regular use of fish oil supplements and concomitant warfarin or anti-platelet agent therapy. Patients are randomized to either EPA-free fatty acid 1 g twice daily or identical placebo AND aspirin 300 mg once daily or identical placebo, for approximately 12 months. The primary end-point is the number of participants with one or more adenomas detected at routine one-year BCSP surveillance colonoscopy. Secondary end-points include the number of adenomas (total and 'advanced') per patient, the location (left versus right colon) of colorectal adenomas and the number of participants re-classified as 'intermediate risk' for future surveillance. Exploratory end-points include levels of bioactive lipid mediators such as ω-3 PUFAs, resolvin E1 and PGE-M in plasma, urine, erythrocytes and rectal mucosa in order to gain insights into the mechanism(s) of action of EPA and aspirin, alone and in combination, as well as to discover predictive biomarkers of chemopreventive efficacy. The recruitment target is 904 patients. Current Controlled Trials ISRCTN05926847.
2013-01-01
Background The naturally-occurring omega (ω)-3 polyunsaturated fatty acid (PUFA) eicosapentaenoic acid (EPA) reduces colorectal adenoma (polyp) number and size in patients with familial adenomatous polyposis. The safety profile and potential cardiovascular benefits associated with ω-3 PUFAs make EPA a strong candidate for colorectal cancer (CRC) chemoprevention, alone or in combination with aspirin, which itself has recognized anti-CRC activity. Colorectal adenoma number and size are recognized as biomarkers of future CRC risk and are established as surrogate end-points in CRC chemoprevention trials. Design The seAFOod Polyp Prevention Trial is a randomized, double-blind, placebo-controlled, 2 × 2 factorial ‘efficacy’ study, which will determine whether EPA prevents colorectal adenomas, either alone or in combination with aspirin. Participants are 55–73 year-old patients, who have been identified as ‘high risk’ (detection of ≥5 small adenomas or ≥3 adenomas with at least one being ≥10 mm in diameter) at screening colonoscopy in the English Bowel Cancer Screening Programme (BCSP). Exclusion criteria include the need for more than one repeat endoscopy within the three-month BCSP screening period, malignant change in an adenoma, regular use of aspirin or non-aspirin non-steroidal anti-inflammatory drugs, regular use of fish oil supplements and concomitant warfarin or anti-platelet agent therapy. Patients are randomized to either EPA-free fatty acid 1 g twice daily or identical placebo AND aspirin 300 mg once daily or identical placebo, for approximately 12 months. The primary end-point is the number of participants with one or more adenomas detected at routine one-year BCSP surveillance colonoscopy. Secondary end-points include the number of adenomas (total and ‘advanced’) per patient, the location (left versus right colon) of colorectal adenomas and the number of participants re-classified as ‘intermediate risk’ for future surveillance. Exploratory end-points include levels of bioactive lipid mediators such as ω-3 PUFAs, resolvin E1 and PGE-M in plasma, urine, erythrocytes and rectal mucosa in order to gain insights into the mechanism(s) of action of EPA and aspirin, alone and in combination, as well as to discover predictive biomarkers of chemopreventive efficacy. The recruitment target is 904 patients. Trial Registration Current Controlled Trials ISRCTN05926847 PMID:23895505
Genetics, biomarkers, hereditary cancer syndrome diagnosis, heterogeneity and treatment: a review.
Lynch, Henry T; Drescher, Kristen; Knezetic, Joseph; Lanspa, Stephen
2014-09-01
Molecular genetic pathways that drive the phenotypic and genotypic heterogeneity of hereditary colorectal cancer also can affect response to chemotherapy and chemoprevention. These mutations also can alter patients' response to therapy. Environmental differences can affect this highly complex conundrum. We will use Lynch syndrome as a model to explore this issue. However, to begin with, after more than a century of documentation, we must ask what is meant by the eponym "Lynch syndrome". Germline mutations may act as drivers of chemoprevention and chemotherapy and therein may act positively or conversely they may have a negative effect in terms of inhibiting the inactivation of cancer-causing germline mutations. A relatively new field of hereditary cancer therapeutics has significantly impacted cancer care, from the standpoint of the sensitivity or resistance to a particular form of chemotherapy and/or chemoprevention. The question for the diagnostician and therapist must always concern what is the best possible management approach for the patient, particularly when he or she harbors a cancer-causing germline mutation, which, in this case, causes Lynch syndrome. Continued molecular genetic research might yield a more tailored effective treatment for Lynch syndrome. The ultimate goal of such hereditary oncologic research is to better understand the mutation's therapeutic task, namely, its potential to benefit the patient in terms of its treatment goal, thereby fulfilling the essence of personalized medicine. However, this goal may be exceedingly complicated. For example, in the natural clinical and molecular genetic history of hereditary forms of cancer, there will be a predominance of early-onset cancers of multiple anatomic sites. In our Lynch syndrome model, these will be most commonly colorectal, endometrial, and ovarian cancer. Attention must initially be focused upon cancer's early age of onset coupled with the tendency to multiple primary cancers so that, in the case of CRC, colonoscopic screening must be initiated by age 20-25 years and repeated every other year until age 40 years and then annually thereafter. However, screening will be of limited efficacy in the gynecologic cancers (endometrial and ovarian) so that once the family is completed, particularly by age 35-40 years, careful attention must be given to the option of prophylactic hysterectomy and bilateral salpingo-oophorectomy. Given issues of tumor heterogeneity, selected Lynch syndrome families may show an excess of urologic cancers or cancers of the small bowel, and highly targeted screening should be given serious consideration for these as well as cancers of other anatomic sites in such high-risk, cancer-prone patients.
Law, Ryan; Das, Ananya; Gregory, Dyanna; Komanduri, Srinadh; Muthusamy, Raman; Rastogi, Amit; Vargo, John; Wallace, Michael B; Raju, G S; Mounzer, Rawad; Klapman, Jason; Shah, Janak; Watson, Rabindra; Wilson, Robert; Edmundowicz, Steven A; Wani, Sachin
2016-06-01
Endoscopic resection (ER) is an efficacious treatment for complex colon polyps (CCPs). Many patients are referred for surgical resection because of concerns over procedural safety, incomplete polyp resection, and adenoma recurrence after ER. Efficacy data for both resection strategies are widely available, but a paucity of data exist on the cost-effectiveness of each modality. The aim of this study was to perform an economic analysis comparing ER and laparoscopic resection (LR) strategies in patients with CCP. A decision analysis tree was constructed using decision analysis software. The 2 strategies (ER vs LR) were evaluated in a hypothetical cohort of patients with CCPs. A hybrid Markov model with a 10-year time horizon was used. Patients entered the model after colonoscopic diagnosis at age 50. Under Strategy I, patients underwent ER followed by surveillance colonoscopy at 3 to 6 months and 12 months. Patients with failed ER and residual adenoma at 12 months were referred for LR. Under Strategy II, patients underwent LR as primary treatment. Patients with invasive cancer were excluded. Estimates regarding ER performance characteristics were obtained from a systematic review of published literature. The Centers for Medicare & Medicaid Services (2012-2013) and the 2012 Healthcare Cost and Utilization Project databases were used to determine the costs and loss of utility. We assumed that all procedures were performed with anesthesia support, and patients with adverse events in both strategies required inpatient hospitalization. Baseline estimates and costs were varied by using a sensitivity analysis through the ranges. LR was found to be more costly and yielded fewer quality-adjusted life-years (QALYs) compared with ER. The cost of ER of a CCP was $5570 per patient and yielded 9.640 QALYs. LR of a CCP cost $18,717 per patient and yielded fewer QALYs (9.577). For LR to be more cost-effective, the thresholds of 1-way sensitivity analyses were (1) technical success of ER for complete resection in <75.8% of cases, (2) adverse event rates for ER > 12%, and (3) LR cost of <$14,000. Our data suggest that ER is a cost-effective strategy for removal of CCPs. The effectiveness is driven by high technical success and low adverse event rates associated with ER, in addition to the increased cost of LR. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Colometer: a real-time quality feedback system for screening colonoscopy.
Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N
2012-08-28
To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.
Paulo, Gustavo Andrade de; Martins, Fernanda Prata Borges; Macedo, Erika Pereira de; Gonçalves, Manoel Ernesto Peçanha; Ferrari, Angelo Paulo
2016-01-01
- Adequate bowel preparation is critical for the quality of colonoscopy. Despite reported occurrence of colonic explosion due to methane and hydrogen production by bacterial fermentation during colonoscopy, gas exchange during the procedure is believed to be effective in lowering existing methane concentration, allowing for safe utilization of mannitol for bowel preparation. Thus, mannitol is widely used for bowel cleansing prior to colonoscopy, considering its low cost and effectiveness for bowel preparation. - The aim of this study was to assess the safety of mannitol for bowel preparation, when compared to sodium phosphate (NaP). - We conducted a prospective observational study in which 250 patients undergoing colonoscopy at Universidade Federal de São Paulo and Hospital Albert Einstein (São Paulo, Brazil) were approached for inclusion in the study. Patients received either mannitol (n=50) or NaP (n=200) for bowel preparation, based on physician indication. Study was conducted from August 2009 to December 2009. The main outcome of interest was presence of detectable levels of methane (CH4) during colonoscopy and reduction in such levels after gas exchange during the procedure. Methane concentrations were measured in three intestinal segments during scope introduction and withdrawal. Safety was assessed as the absence of high levels of methane, defined as 5%. Measurements were made using a multi-gas monitor (X-am 7000, Dräger Safety AG & Co. KGaA, Lübeck, Germany) connected to a plastic catheter introduced into the working channel of the colonoscope. Additional outcomes of interest included levels of O2. Methane and O2 levels are reported as ppm. Mean, difference and standard deviation of levels of gas measured in both moments were calculated and compared in both groups. Proportions of patients with detectable or high levels of methane in both groups were compared. Continuous variables were analyzed using t test and categorical variables using qui-square tests. The Ethics Committee in both study sites approved the study protocol. - Patients in both groups were similar regarding demographics, colonoscopy indication, ASA status and quality of bowel preparation. Seven (3.5%) patients in the NaP group had methane detected during introduction of the endoscope. Methane levels became undetectable during withdrawal of the scope. None of the patients in the mannitol group had detectable levels of methane. O2 levels did not differ in the groups. - This is the largest study to assess the safety of mannitol for bowel preparation, considering methane measurements. Our results indicate that mannitol use is as safe as NaP, and gas exchange was efficient in reducing methane concentrations.
Paramsothy, Sudarshan; Kamm, Michael A; Kaakoush, Nadeem O; Walsh, Alissa J; van den Bogaerde, Johan; Samuel, Douglas; Leong, Rupert W L; Connor, Susan; Ng, Watson; Paramsothy, Ramesh; Xuan, Wei; Lin, Enmoore; Mitchell, Hazel M; Borody, Thomas J
2017-03-25
The intestinal microbiota is implicated in the pathogenesis of ulcerative colitis. Faecal microbiota transplantation is a novel form of therapeutic microbial manipulation, but its efficacy in ulcerative colitis is uncertain. We aimed to establish the efficacy of intensive-dosing, multidonor, faecal microbiota transplantation in active ulcerative colitis. We conducted a multicentre, double-blind, randomised, placebo-controlled trial at three hospitals in Australia. We randomly allocated patients with active ulcerative colitis (Mayo score 4-10) in a 1:1 ratio, using a pre-established randomisation list, to either faecal microbiota transplantation or placebo colonoscopic infusion, followed by enemas 5 days per week for 8 weeks. Patients, treating clinicians, and other study staff were unaware of the assigned treatment. Faecal microbiota transplantation enemas were each derived from between three and seven unrelated donors. The primary outcome was steroid-free clinical remission with endoscopic remission or response (Mayo score ≤2, all subscores ≤1, and ≥1 point reduction in endoscopy subscore) at week 8. Analysis was by modified intention-to-treat and included all patients receiving one study dose. We performed 16S rRNA stool analysis to assess associated microbial changes. This trial is registered with ClinicalTrials.gov, number NCT01896635. The trial has ended; this report presents the final analysis. From November, 2013, to May, 2015, 85 patients were enrolled to our trial, of whom 42 were randomly assigned faecal microbiota transplantation and 43 were allocated placebo. One patient assigned faecal microbiota transplantation and three allocated placebo did not receive study treatment and were excluded from the analysis. The primary outcome was achieved in 11 (27%) of 41 patients allocated faecal microbiota transplantation versus three (8%) of 40 who were assigned placebo (risk ratio 3·6, 95% CI 1·1-11·9; p=0·021). Adverse events were reported by 32 (78%) of 41 patients allocated faecal microbiota transplantation and 33 (83%) of 40 who were assigned placebo; most were self-limiting gastrointestinal complaints, with no significant difference in number or type of adverse events between treatment groups. Serious adverse events occurred in two patients assigned faecal microbiota transplantation and in one allocated placebo. Microbial diversity increased with and persisted after faecal microbiota transplantation. Several bacterial taxa were associated with clinical outcome; in particular, the presence of Fusobacterium spp was associated with lack of remission. Intensive-dosing, multidonor, faecal microbiota transplantation induces clinical remission and endoscopic improvement in active ulcerative colitis and is associated with distinct microbial changes that relate to outcome. Faecal microbiota transplantation is, thus, a promising new therapeutic option for ulcerative colitis. Future work should focus on precisely defining the optimum treatment intensity and the role of donor-recipient matching based on microbial profiles. Broad Medical Research Program, Gastroenterological Society of Australia, Mount Sinai (New York) SUCCESS fund, University of New South Wales. Copyright © 2017 Elsevier Ltd. All rights reserved.
1995-11-01
Surgical video systems (SVSs), which typically consist of a video camera attached to an optical endoscope, a video processor, a light source, and a video monitor, are now being used to perform a significant number of minimally invasive surgical procedures. SVSs offer several advantages (e.g., multiple viewer visualization of the surgical site, increased clinician comfort) over nonvideo systems and have increased the practicality and convenience of minimally invasive surgery (MIS). Currently, SVSs are used by hospitals in their general, obstetric/gynecologic, orthopedic, thoracic, and urologic procedures, as well as in other specialties for which MIS is feasible. In this study, we evaluated 19 SVSs from 10 manufacturers, focusing on their use in laparoscopic applications in general surgery. We based our ratings on the usefulness of each system's video performance and features in helping clinicians provide safe and efficacious laparoscopic surgery. We rated 18 of the systems Acceptable because of their overall good performance and features. We rated 1 system Conditionally Acceptable because, compared with the other evaluated systems, this SVS presents a greater risk of thermal injury resulting from excessive heating at the distal tip of the laparoscope. Readers should be aware that our test results, conclusions, and ratings apply only to the specific systems and components tested in this Evaluation. In addition, although our discussion focuses on the laparoscopic application of SVSs, much of the information in this study also applies to other MIS applications, and the evaluated devices can be used in a variety of surgical procedures. To help hospitals gain the perspectives necessary to assess the appropriateness of specific SVSs to ensure that the needs of their patients, as well as the expectations of their clinicians, will be satisfied, we have included a Selection and Purchasing Guide that can be used as a supplement to our Evaluation findings. We have also included a Glossary of relevant terminology and the supplementary article, "Fiberoptic Illumination Systems and the Risk of Burns or Fire during Endoscopic Procedures," which addresses a safety concern with the use of these devices. While we made every effort to present the most current information, readers should recognize that this is a rapidly evolving technology, and developments occurring after our study was complete may not be reflected in the text. For additional information on topics related to this study, refer to the following Health Devices articles: (1) our Guidance Article, "Surgical Video Systems Used in Laparoscopy," 24(1), January 1995, which serves as an introduction to SVS terminology and includes a discussion of the significance of many SVS specifications; (2) our Evaluation, "Video Colonoscope Systems," 23(5), May 1994, which includes a detailed overview of video endoscopic applications and technology; and (3) our Evaluations of laparoscopic insufflators (21[5], May 1992, and 24[7], July 1995), which address issues related to the creation of a viewing and working space inside the peritoneal cavity to facilitate visualization in laparoscopic procedures.
Snowsill, Tristan; Coelho, Helen; Huxley, Nicola; Jones-Hughes, Tracey; Briscoe, Simon; Frayling, Ian M; Hyde, Chris
2017-09-01
Inherited mutations in deoxyribonucleic acid (DNA) mismatch repair (MMR) genes lead to an increased risk of colorectal cancer (CRC), gynaecological cancers and other cancers, known as Lynch syndrome (LS). Risk-reducing interventions can be offered to individuals with known LS-causing mutations. The mutations can be identified by comprehensive testing of the MMR genes, but this would be prohibitively expensive in the general population. Tumour-based tests - microsatellite instability (MSI) and MMR immunohistochemistry (IHC) - are used in CRC patients to identify individuals at high risk of LS for genetic testing. MLH1 (MutL homologue 1) promoter methylation and BRAF V600E testing can be conducted on tumour material to rule out certain sporadic cancers. To investigate whether testing for LS in CRC patients using MSI or IHC (with or without MLH1 promoter methylation testing and BRAF V600E testing) is clinically effective (in terms of identifying Lynch syndrome and improving outcomes for patients) and represents a cost-effective use of NHS resources. Systematic reviews were conducted of the published literature on diagnostic test accuracy studies of MSI and/or IHC testing for LS, end-to-end studies of screening for LS in CRC patients and economic evaluations of screening for LS in CRC patients. A model-based economic evaluation was conducted to extrapolate long-term outcomes from the results of the diagnostic test accuracy review. The model was extended from a model previously developed by the authors. Ten studies were identified that evaluated the diagnostic test accuracy of MSI and/or IHC testing for identifying LS in CRC patients. For MSI testing, sensitivity ranged from 66.7% to 100.0% and specificity ranged from 61.1% to 92.5%. For IHC, sensitivity ranged from 80.8% to 100.0% and specificity ranged from 80.5% to 91.9%. When tumours showing low levels of MSI were treated as a positive result, the sensitivity of MSI testing increased but specificity fell. No end-to-end studies of screening for LS in CRC patients were identified. Nine economic evaluations of screening for LS in CRC were identified. None of the included studies fully matched the decision problem and hence a new economic evaluation was required. The base-case results in the economic evaluation suggest that screening for LS in CRC patients using IHC, BRAF V600E and MLH1 promoter methylation testing would be cost-effective at a threshold of £20,000 per quality-adjusted life-year (QALY). The incremental cost-effectiveness ratio for this strategy was £11,008 per QALY compared with no screening. Screening without tumour tests is not predicted to be cost-effective. Most of the diagnostic test accuracy studies identified were rated as having a risk of bias or were conducted in unrepresentative samples. There was no direct evidence that screening improves long-term outcomes. No probabilistic sensitivity analysis was conducted. Systematic review evidence suggests that MSI- and IHC-based testing can be used to identify LS in CRC patients, although there was heterogeneity in the methods used in the studies identified and the results of the studies. There was no high-quality empirical evidence that screening improves long-term outcomes and so an evidence linkage approach using modelling was necessary. Key determinants of whether or not screening is cost-effective are the accuracy of tumour-based tests, CRC risk without surveillance, the number of relatives identified for cascade testing, colonoscopic surveillance effectiveness and the acceptance of genetic testing. Future work should investigate screening for more causes of hereditary CRC and screening for LS in endometrial cancer patients. This study is registered as PROSPERO CRD42016033879. The National Institute for Health Research Health Technology Assessment programme.
Bell, Charreau S; Obstein, Keith L; Valdastri, Pietro
2013-11-01
Colorectal cancer is one of the leading causes of cancer-related deaths in the world, although it can be effectively treated if detected early. Teleoperated flexible endoscopes are an emerging technology to ease patient apprehension about the procedure, and subsequently increase compliance. Essential to teleoperation is robust feedback reflecting the change in pose (i.e., position and orientation) of the tip of the endoscope. The goal of this study is to first describe a novel image-based tracking system for teleoperated flexible endoscopes, and subsequently determine its viability in a clinical setting. The proposed approach leverages artificial neural networks (ANNs) to learn the mapping that links the optical flow between two sequential images to the change in the pose of the camera. Secondly, the study investigates for the first time how narrow band illumination (NBI) - today available in commercial gastrointestinal endoscopes - can be applied to enhance feature extraction, and quantify the effect of NBI and white light illumination (WLI), as well as their color information, on the strength of features extracted from the endoscopic camera stream. In order to provide the best features for the neural networks to learn the change in pose based on the image stream, we investigated two different imaging modalities - WLI and NBI - and we applied two different spatial partitions - lumen-centered and grid-based - to create descriptors used as input to the ANNs. An experiment was performed to compare the error of these four variations, measured in root mean square error (RMSE) from ground truth given by a robotic arm, to that of a commercial state-of-the-art magnetic tracker. The viability of this technique for a clinical setting was then tested using the four ANN variations, a magnetic tracker, and a commercial colonoscope. The trial was performed by an expert endoscopist (>2000 lifetime procedures) on a colonoscopy training model with porcine blood, and the RMSE of the ANN output was calculated with respect to the magnetic tracker readings. Using the image stream obtained from the commercial endoscope, the strength of features extracted was evaluated. In the first experiment, the best ANNs resulted from grid-based partitioning under WLI (2.42mm RMSE) for position, and from lumen-centered partitioning under NBI (1.69° RMSE) for rotation. By comparison, the performance of the tracker was 2.49mm RMSE in position and 0.89° RMSE in rotation. The trial with the commercial endoscope indicated that lumen-centered partitioning was the best overall, while NBI outperformed WLI in terms of illumination modality. The performance of lumen-centered partitioning with NBI was 1.03±0.8mm RMSE in positional degrees of freedom (DOF), and 1.26±0.98° RMSE in rotational DOF, while with WLI, the performance was 1.56±1.15mm RMSE in positional DOF and 2.45±1.90° RMSE in rotational DOF. Finally, the features extracted under NBI were found to be twice as strong as those extracted under WLI, but no significance in feature strengths was observed between a grayscale version of the image, and the red, blue, and green color channels. This work demonstrates that both WLI and NBI, combined with feature partitioning based on the anatomy of the colon, provide valid mechanisms for endoscopic camera pose estimation via image stream. Illumination provided by WLI and NBI produce ANNs with similar performance which are comparable to that of a state-of-the-art magnetic tracker. However, NBI produces features that are stronger than WLI, which enables more robust feature tracking, and better performance of the ANN in terms of accuracy. Thus, NBI with lumen-centered partitioning resulted the best approach among the different variations tested for vision-based pose estimation. The proposed approach takes advantage of components already available in commercial gastrointestinal endoscopes to provide accurate feedback about the motion of the tip of the endoscope. This solution may serve as an enabling technology for closed-loop control of teleoperated flexible endoscopes. Copyright © 2013 Elsevier B.V. All rights reserved.