Sample records for colonoscopy population-based study

  1. Optimal use of colonoscopy and fecal immunochemical test for population-based colorectal cancer screening: a cost-effectiveness analysis using Japanese data.

    PubMed

    Sekiguchi, Masau; Igarashi, Ataru; Matsuda, Takahisa; Matsumoto, Minori; Sakamoto, Taku; Nakajima, Takeshi; Kakugawa, Yasuo; Yamamoto, Seiichiro; Saito, Hiroshi; Saito, Yutaka

    2016-02-01

    There have been few cost-effectiveness analyses of population-based colorectal cancer screening in Japan, and there is no consensus on the optimal use of total colonoscopy and the fecal immunochemical test for colorectal cancer screening with regard to cost-effectiveness and total colonoscopy workload. The present study aimed to examine the cost-effectiveness of colorectal cancer screening using Japanese data to identify the optimal use of total colonoscopy and fecal immunochemical test. We developed a Markov model to assess the cost-effectiveness of colorectal cancer screening offered to an average-risk population aged 40 years or over. The cost, quality-adjusted life-years and number of total colonoscopy procedures required were evaluated for three screening strategies: (i) a fecal immunochemical test-based strategy; (ii) a total colonoscopy-based strategy; (iii) a strategy of adding population-wide total colonoscopy at 50 years to a fecal immunochemical test-based strategy. All three strategies dominated no screening. Among the three, Strategy 1 was dominated by Strategy 3, and the incremental cost per quality-adjusted life-years gained for Strategy 2 against Strategies 1 and 3 were JPY 293 616 and JPY 781 342, respectively. Within the Japanese threshold (JPY 5-6 million per QALY gained), Strategy 2 was the most cost-effective, followed by Strategy 3; however, Strategy 2 required more than double the number of total colonoscopy procedures than the other strategies. The total colonoscopy-based strategy could be the most cost-effective for population-based colorectal cancer screening in Japan. However, it requires more total colonoscopy procedures than the other strategies. Depending on total colonoscopy capacity, the strategy of adding total colonoscopy for individuals at a specified age to a fecal immunochemical test-based screening may be an optimal solution. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Differences in detection rates of adenomas and serrated polyps in screening versus surveillance colonoscopies, based on the new hampshire colonoscopy registry.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Goodrich, Martha; Robinson, Christina M; Weiss, Julia E

    2013-10-01

    The adenoma detection rate (ADR) is an important quality indicator originally developed for screening colonoscopies. However, it is unclear whether the ADR should be calculated using data from screening and surveillance examinations. The recommended benchmark ADR for screening examinations is 20% (15% for women and 25% for men ≥50 y). There are few data available to compare ADRs from surveillance vs screening colonoscopies. We used a population-based registry to compare ADRs from screening vs surveillance colonoscopies. The serrated polyp detection rate (SDR), a potential new quality indicator, also was examined. By using data from the statewide New Hampshire Colonoscopy Registry, we excluded incomplete and diagnostic colonoscopies, and those performed in patients with inflammatory bowel disease, familial syndromes, or poor bowel preparation. We calculated the ADR and SDR (number of colonoscopies with at least 1 adenoma or serrated polyp detected, respectively, divided by the number of colonoscopies) from 9100 colonoscopies. The ADR and SDR were compared by colonoscopy indication (screening, surveillance), age at colonoscopy (50-64 y, ≥65 y), and sex. The ADR was significantly higher in surveillance colonoscopies (37%) than screening colonoscopies (25%; P < .001). This difference was observed for both sexes and age groups. There was a smaller difference in the SDR of screening (8%) vs surveillance colonoscopies (10%; P < .001). In a population-based study, we found that addition of data from surveillance colonoscopies increased the ADR but had a smaller effect on the SDR. These findings indicate that when calculating ADR as a quality measure, endoscopists should use screening, rather than surveillance colonoscopy, data. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Differences in Detection Rates of Adenomas and Serrated Polyps in Screening Versus Surveillance Colonoscopies, Based on the New Hampshire Colonoscopy Registry

    PubMed Central

    ANDERSON, JOSEPH C.; BUTTERLY, LYNN; GOODRICH, MARTHA; ROBINSON, CHRISTINA M.; WEISS, JULIA E.

    2013-01-01

    BACKGROUND & AIMS The adenoma detection rate (ADR) is an important quality indicator originally developed for screening colonoscopies. However, it is unclear whether the ADR should be calculated using data from screening and surveillance examinations. The recommended benchmark ADR for screening examinations is 20% (15% for women and 25% for men ≥ 50 y). There are few data available to compare ADRs from surveillance vs screening colonoscopies. We used a population-based registry to compare ADRs from screening vs surveillance colonoscopies. The serrated polyp detection rate (SDR), a potential new quality indicator, also was examined. METHODS By using data from the statewide New Hampshire Colonoscopy Registry, we excluded incomplete and diagnostic colonoscopies, and those performed in patients with inflammatory bowel disease, familial syndromes, or poor bowel preparation. We calculated the ADR and SDR (number of colonoscopies with at least 1 adenoma or serrated polyp detected, respectively, divided by the number of colonoscopies) from 9100 colonoscopies. The ADR and SDR were compared by colonoscopy indication (screening, surveillance), age at colonoscopy (50–64 y, ≥65 y), and sex. RESULTS The ADR was significantly higher in surveillance colonoscopies (37%) than screening colonoscopies (25%; P < .001). This difference was observed for both sexes and age groups. There was a smaller difference in the SDR of screening (8%) vs surveillance colonoscopies (10%; P < .001). CONCLUSIONS In a population-based study, we found that addition of data from surveillance colonoscopies increased the ADR, but had a smaller effect on the SDR. These findings indicate that when calculating ADR as a quality measure, endoscopists should use screening, rather than surveillance colonoscopy, data. PMID:23660415

  4. Intention to undergo colonoscopy screening among relatives of colorectal cancer cases: a theory-based model.

    PubMed

    Boonyasiriwat, Watcharaporn; Hung, Man; Hon, Shirley D; Tang, Philip; Pappas, Lisa M; Burt, Randall W; Schwartz, Marc D; Stroup, Antoinette M; Kinney, Anita Y

    2014-06-01

    It is recommended that persons having familial risk of colorectal cancer begin regular colonoscopy screening at an earlier age than those in the general population. However, many individuals at increased risk do not adhere to these screening recommendations. The goal of this study was to examine cognitive, affective, social, and behavioral motivators of colonoscopy intention among individuals at increased risk of familial colorectal cancer. Relatives of colorectal cancer cases (N = 481) eligible for colonoscopy screening completed a survey assessing constructs from several theoretical frameworks including fear appeal theories. Structural equation modeling indicated that perceived colorectal cancer risk, past colonoscopy, fear of colorectal cancer, support from family and friends, and health-care provider recommendation were determinants of colonoscopy intention. Future interventions to promote colonoscopy in this increased risk population should target the factors we identified as motivators. (ClinicalTrials.gov number NCT01274143).

  5. Matching colonoscopy and pathology data in population-based registries: development of a novel algorithm and the initial experience of the New Hampshire Colonoscopy Registry.

    PubMed

    Greene, Mary Ann; Butterly, Lynn F; Goodrich, Martha; Onega, Tracy; Baron, John A; Lieberman, David A; Dietrich, Allen J; Srivastava, Amitabh

    2011-08-01

    The quality of polyp-level data in a population-based registry depends on the ability to match each polypectomy recorded by the endoscopist to a specific diagnosis on the pathology report. To review impediments encountered in matching colonoscopy and pathology data in a population-based registry. New Hampshire Colonoscopy Registry data from August 2006 to November 2008 were analyzed for prevalence of missing reports, discrepancies between colonoscopy and pathology reports, and the proportion of polyps that could not be matched because of multiple polyps submitted in the same container. New Hampshire Colonoscopy Registry. This study involved all consenting patients during the study period. Develop an algorithm for capturing number, size, location, and histology of polyps and for defining and flagging discrepancies to ensure data quality. The proportion of polyps with no assumption or discrepancy, the proportion of patient records eligible for determining the adenoma detection rate (ADR), and the number of patients with ≥3 adenomas. Only 50% of polyps removed during this period were perfectly matched, with no assumption or discrepancy. Records from only 69.9% and 29.7% of eligible patients could be used to determine the ADR and the number of patients with ≥3 adenomas, respectively. Rates of missing reports may have been higher in the early phase of establishment of the registry. This study highlights the impediments in collecting polyp-level data in a population-based registry and provides useful parameters for evaluating the quality and accuracy of data obtained from such registries. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  6. Cost-Effectiveness of Patient Navigation to Increase Adherence with Screening Colonoscopy Among Minority Individuals

    PubMed Central

    Ladabaum, Uri; Mannalithara, Ajitha; Jandorf, Lina; Itzkowitz, Steven H.

    2015-01-01

    Background Colorectal cancer (CRC) screening is underutilized by minority populations. Patient navigation increases adherence with screening colonoscopy. We estimated the cost-effectiveness of navigation for screening colonoscopy from the perspective of a payer seeking to improve population health. Methods We informed our validated model of CRC screening with inputs from navigation studies in New York City (population 43% African American, 49% Hispanic, 4% White, 4% Other; base case screening 40% without and 65% with navigation, navigation costs $29/colonoscopy completer, $21/non-completer, $3/non-navigated). We compared: 1) navigation vs. no navigation for one-time screening colonoscopy in unscreened persons age ≥50; 2) programs of colonoscopy with vs. without navigation, vs. fecal occult blood testing (FOBT) or immunochemical testing (FIT) for ages 50-80. Results In the base case: 1) one-time navigation gained quality-adjusted life-years (QALYs) and decreased costs; 2) longitudinal navigation cost $9,800/QALY gained vs. no navigation, and assuming comparable uptake rates, it cost $118,700/QALY gained vs. FOBT, but was less effective and more costly than FIT. Results were most dependent on screening participation rates and navigation costs: 1) assuming a 5% increase in screening uptake with navigation and navigation cost of $150/completer, one-time navigation cost $26,400/QALY gained; 2) longitudinal navigation with 75% colonoscopy uptake cost <$25,000/QALY gained vs. FIT when FIT uptake was <50%. Probabilistic sensitivity analyses did not alter the conclusions. Conclusions Navigation for screening colonoscopy appears to be cost-effective, and one-time navigation may be cost-saving. In emerging healthcare models that reward outcomes, payers should consider covering the costs of navigation for screening colonoscopy. PMID:25492455

  7. The NordICC Study: Rationale and design of a randomized trial on colonoscopy screening for colorectal cancer

    PubMed Central

    F.Kaminski, Michal; Bretthauer, Michael; Zauber, Ann G.; Kuipers, Ernst J.; Adami, Hans-Olov; van Ballegooijen, Marjolein; Regula, Jaroslaw; van Leerdam, Monique; Stefansson, Tryggvi; Påhlman, Lars; Dekker, Evelien; Hernán, Miguel A.; Garborg, Kjetil; Hoff, Geir

    2017-01-01

    Background While colonoscopy screening is widely used in several European countries and the United States, no randomised trials exist to quantify its benefits. The Nordic-European Initiative on Colorectal Cancer (NordICC) is a multinational, randomized controlled trial aiming at investigating the effect of colonoscopy screening on CRC incidence and mortality. This paper describes the rationale and design of the NordICC trial. Material and methods Men and women age 55 to 64 years are drawn from the population registries in the participating countries and randomly assigned to either once-only colonoscopy screening with removal of all detected lesions, or no screening (standard of care in the trial regions). All individuals are followed for 15 years after inclusion using dedicated national registries. Results The primary endpoints of the trial are cumulative CRC-specific death and CRC incidence during 15 years of follow up. We hypothesize a 50% CRC mortality-reducing efficacy of the colonoscopy intervention and predict 50% compliance, yielding a 25% mortality reduction among those invited to screening. For 90% power and a two-sided alpha level of 0.05, using a 2:1 randomisation, 45,600 individuals will be randomised to control, and 22,800 individuals to the colonoscopy group. Interim analyses of the effect of colonoscopy on CRC incidence and mortality will be performed at 10 years follow-up. Conclusions The aim of the NordICC trial is to quantify the effectiveness of population-based colonoscopy screening. This will allow development of evidence-based guidelines for CRC screening in the general population. PMID:22723185

  8. Serious events in older Ontario residents receiving bowel preparations for outpatient colonoscopy with various comorbidity profiles: A descriptive, population-based study

    PubMed Central

    Ho, Joanne M; Gruneir, Andrea; Fischer, Hadas D; Fu, Longdi; Lipscombe, Lorraine L; Bell, Chaim M; Cavalcanti, Rodrigo B; Anderson, Geoffrey M; Rochon, Paula A

    2012-01-01

    BACKGROUND: Polyethylene glycol-based bowel preparations (PEGBPs) and sodium picosulfate (NaPS) are commonly used for bowel cleansing before colonoscopy. Little is known about adverse events associated with these preparations, particularly in older patients or patients with medical comorbidities. OBJECTIVE: To characterize the incidence of serious events following outpatient colonoscopy in patients using PEGBPs or NaPS. METHODS: The present population-based retrospective cohort study examined data from Ontario health care databases between April 1, 2005 and December 31, 2007, including patients ≥66 years of age who received either PEGBP or NaPS for an outpatient colonoscopy. Patients with cardiac or renal disease, long-term care residents or patients receiving concurrent diuretic therapy were identified as high risk for adverse events. The primary outcome was a serious event (SE) defined as a composite of nonelective hospitalization, emergency department visit or death within seven days of the colonoscopy. RESULTS: Of the 50,660 outpatients ≥66 years of age who underwent a colonoscopy, SEs were observed in 675 (2.4%) and 543 (2.4%) patients in the PEGBP and NaPS groups, respectively. Among high-risk patients (n=30,168), SEs occurred in 481 (2.8%) and 367 (2.8%) of patients receiving PEGBP and NaPS, respectively. CONCLUSIONS: The SE rate within seven days of outpatient colonoscopy was 24 per 1000 procedures, and among high-risk patients was 28 per 1000 procedures. The rates were similar for PEGBP and NaPS. Clinicians should be aware of the risks associated with colonoscopy in older patients with comorbidities. PMID:22803018

  9. Patient Navigation for Colonoscopy Completion: Results of an RCT.

    PubMed

    DeGroff, Amy; Schroy, Paul C; Morrissey, Kerry Grace; Slotman, Beth; Rohan, Elizabeth A; Bethel, James; Murillo, Jennifer; Ren, Weijia; Niwa, Shelley; Leadbetter, Steven; Joseph, Djenaba

    2017-09-01

    Colorectal cancer is a leading cause of cancer-related death in the U.S. Although screening reduces colorectal cancer incidence and mortality, screening rates among U.S. adults remain less than optimal, especially among disadvantaged populations. This study examined the efficacy of patient navigation to increase colonoscopy screening. RCT. A total of 843 low-income adults, primarily Hispanic and non-Hispanic blacks, aged 50-75 years referred for colonoscopy at Boston Medical Center were randomized into the intervention (n=429) or control (n=427) groups. Participants were enrolled between September 2012 and December 2014, with analysis following through 2015. Two bilingual lay navigators provided individualized education and support to reduce patient barriers and facilitate colonoscopy completion. The intervention was delivered largely by telephone. Colonoscopy completion within 6 months of study enrollment. Colonoscopy completion was significantly higher for navigated patients (61.1%) than control group patients receiving usual care (53.2%, p=0.021). Based on regression analysis, the odds of completing a colonoscopy for navigated patients was one and a half times greater than for controls (95% CI=1.12, 2.03, p=0.007). There were no differences between navigated and control groups in regard to adequacy of bowel preparation (95.3% vs 97.3%, respectively). Navigation significantly improved colonoscopy screening completion among a racially diverse, low-income population. Results contribute to mounting evidence demonstrating the efficacy of patient navigation in increasing colorectal cancer screening. Screening can be further enhanced when navigation is combined with other evidence-based practices implemented in healthcare systems and the community. Copyright © 2017. Published by Elsevier Inc.

  10. Colonoscopy demand and capacity in New Hampshire.

    PubMed

    Butterly, Lynn; Olenec, Christopher; Goodrich, Martha; Carney, Patricia; Dietrich, Allen

    2007-01-01

    Screening for colorectal cancer has been clearly shown to decrease the incidence and mortality from this disease. Accurate information about the demand and capacity for screening, particularly with colonoscopy, is critical in planning screening strategies. National assessments have recently begun; estimates of smaller geographic regions should improve the accuracy of national estimates, as well as inform strategies for individual states. This study evaluates the demand and capacity for colonoscopy in the state of New Hampshire. All endoscopy sites in the state of New Hampshire were contacted to determine their number of endoscopists, monthly colonoscopies, and estimates of the percentage of colonoscopy done for screening. Barriers to increasing current capacity were also assessed. The capacity estimates were compared to demand estimates based on population census figures. Data were collected in 2003 to 2004 and analyzed in 2005 to 2006. One hundred fourteen endoscopists at 36 centers performed 49,352 colonoscopies in 2002, an average of 39 to 43 total monthly colonoscopies per endoscopist. Approximately 60% were estimated to have been done for screening. Estimated demand was approximately twice the available capacity for screening and surveillance. The impact of factors such as compliance, percent screening, and population growth were assessed to inform future screening strategies. In 2002, demand for screening colonoscopy in New Hampshire for patients aged more than 50 years was approximately twice the available capacity. However, if the assessed screening capacity of 2002 were to increase by 20%, combined with a target of 60% population compliance with screening as an initial goal, the demand for colonoscopy in New Hampshire would be met.

  11. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation.

    PubMed

    Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-06-21

    In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation.

  12. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation

    PubMed Central

    Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-01-01

    Background In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective Objective of this study was to assess the function of an automated text messaging (short message service, SMS)–supported colonoscopy preparation starting 4 days before colonoscopy appointment. Methods After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging–provided information assessed by a questionnaire. Results Web-based SMS text messaging–supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging–based information was high. Conclusions Using SMS for colonoscopy preparation with 4 days’ guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation. PMID:27329204

  13. Outreach invitations for FIT and colonoscopy improve colorectal cancer screening rates: A randomized controlled trial in a safety-net health system.

    PubMed

    Singal, Amit G; Gupta, Samir; Tiro, Jasmin A; Skinner, Celette Sugg; McCallister, Katharine; Sanders, Joanne M; Bishop, Wendy Pechero; Agrawal, Deepak; Mayorga, Christian A; Ahn, Chul; Loewen, Adam C; Santini, Noel O; Halm, Ethan A

    2016-02-01

    The effectiveness of colorectal cancer (CRC) screening is limited by underuse, particularly among underserved populations. Among a racially diverse and socioeconomically disadvantaged cohort of patients, the authors compared the effectiveness of fecal immunochemical test (FIT) outreach and colonoscopy outreach to increase screening participation rates, compared with usual visit-based care. Patients aged 50 to 64 years who were not up-to-date with CRC screening but used primary care services in a large safety-net health system were randomly assigned to mailed FIT outreach (2400 patients), mailed colonoscopy outreach (2400 patients), or usual care with opportunistic visit-based screening (1199 patients). Patients who did not respond to outreach invitations within 2 weeks received follow-up telephone reminders. The primary outcome was CRC screening completion within 12 months after randomization. Baseline patient characteristics across the 3 groups were similar. Using intention-to-screen analysis, screening participation rates were higher for FIT outreach (58.8%) and colonoscopy outreach (42.4%) than usual care (29.6%) (P <.001 for both). Screening participation with FIT outreach was higher than that for colonoscopy outreach (P <.001). Among responders, FIT outreach had a higher percentage of patients who responded before reminders (59.0% vs 29.7%; P <.001). Nearly one-half of patients in the colonoscopy outreach group crossed over to complete FIT via usual care, whereas <5% of patients in the FIT outreach group underwent usual-care colonoscopy. Mailed outreach invitations appear to significantly increase CRC screening rates among underserved populations. In the current study, FIT-based outreach was found to be more effective than colonoscopy-based outreach to increase 1-time screening participation. Studies with longer follow-up are needed to compare the effectiveness of outreach strategies for promoting completion of the entire screening process. © 2015 American Cancer Society.

  14. Opportunistic screening of hospital staff using primary colonoscopy: participation, discomfort and willingness to repeat the procedure.

    PubMed

    Khalid-de Bakker, C A; Jonkers, D M; Hameeteman, W; de Ridder, R J; Masclee, A A; Stockbrügger, R W

    2011-01-01

    Participation in and tolerability of primary colonoscopy screening are presumed to be relatively low. The present study aimed to test its feasibility in a well-informed population of hospital staff using an intensive information campaign, and to identify factors associated with screening colonoscopy rated as uncomfortable. Data were collected using standardized forms. Out of 1,090 invited employees (50-65 years), 447 (41.0%) participated. Bowel preparation and colonoscopy were rated as 'somewhat to very uncomfortable' by 79.5 and 21.9%, respectively. 96.3% of participants were willing to repeat colonoscopy in the future. Participants rating colonoscopy as uncomfortable were more likely unwilling to repeat the procedure (OR 8.026, CI 2.667-24.154). Multivariate analysis (age- and gender-adjusted) showed an association of colonoscopy rated as uncomfortable with: abdominal pain during colonoscopy (OR 3.185, CI 1.642-6.178), other pain (OR 2.428, CI 1.335-4.416), flatulence (OR 2.175, CI 1.219-3.881), embarrassment (OR 2.843, CI 1.350-5.989), abdominal pain after colonoscopy (OR 1.976, CI 1.041-3.751), and a prolonged procedure time (OR 1.000, CI 1.000-1.001). Acceptance of primary colonoscopy screening for colorectal neoplasia was high, although participants with symptoms during and after colonoscopy were more likely to rate colonoscopy as uncomfortable. This type of opportunistic screening procedure is suitable for the introduction of screening programs and may be useful in areas that have no access to population-based screening. Copyright © 2011 S. Karger AG, Basel.

  15. Colorectal cancer screening: Estimated future colonoscopy need and current volume and capacity.

    PubMed

    Joseph, Djenaba A; Meester, Reinier G S; Zauber, Ann G; Manninen, Diane L; Winges, Linda; Dong, Fred B; Peaker, Brandy; van Ballegooijen, Marjolein

    2016-08-15

    In 2014, a national campaign was launched to increase colorectal cancer (CRC) screening rates in the United States to 80% by 2018; it is unknown whether there is sufficient colonoscopy capacity to reach this goal. This study estimated the number of colonoscopies needed to screen 80% of the eligible population with fecal immunochemical testing (FIT) or colonoscopy and determined whether there was sufficient colonoscopy capacity to meet the need. The Microsimulation Screening Analysis-Colon model was used to simulate CRC screening test use in the United States (2014-2040); the implementation of a national screening program in 2014 with FIT or colonoscopy with 80% participation was assumed. The 2012 Survey of Endoscopic Capacity (SECAP) estimated the number of colonoscopies that were performed and the number that could be performed. If a national screening program started in 2014, by 2024, approximately 47 million FIT procedures and 5.1 million colonoscopies would be needed annually to screen the eligible population with a program using FIT as the primary screening test; approximately 11 to 13 million colonoscopies would be needed annually to screen the eligible population with a colonoscopy-only screening program. According to the SECAP survey, an estimated 15 million colonoscopies were performed in 2012, and an additional 10.5 million colonoscopies could be performed. The estimated colonoscopy capacity is sufficient to screen 80% of the eligible US population with FIT, colonoscopy, or a mix of tests. Future analyses should take into account the geographic distribution of colonoscopy capacity. Cancer 2016;122:2479-86. © 2016 American Cancer Society. © 2016 American Cancer Society.

  16. Delivering colonoscopy screening for low-income populations in Suffolk County: strategies, outcomes, and benchmarks.

    PubMed

    Lane, Dorothy S; Messina, Catherine R; Cavanagh, Mary F; Anderson, Joseph C

    2013-08-01

    Current and pending legislation provides colorectal cancer screening reimbursement for previously uninsured populations. Colonoscopy is currently the screening method most frequently recommended by physicians for insured patients. The experience of the SCOPE (Suffolk County Preventive Endoscopy) demonstration project (Project SCOPE) at Stony Brook University Medical Center provides a model for delivering colonoscopy screening to low-income populations to meet anticipated increasing demands. Project SCOPE, based in the Department of Preventive Medicine, featured internal collaboration with the academic medical center's large gastroenterology practice and external collaboration with the Suffolk County Department of Health Services' network of community health centers. Colonoscopies were performed by faculty gastroenterologists or supervised fellows. Measures of colonoscopy performance were compared with quality indicators and differences between faculty and supervised fellows were identified. During a 40-month screening period, 800 initial colonoscopies were performed. Approximately 21% of women screened were found to have adenomatous polyps compared with 36% of men. Five cancers were detected. The majority of the population screened (70%) were members of minority populations. African American individuals had a higher percentage of proximally located adenomas (78%) compared with white individuals (65%) and Hispanics (49%), based on the location of the most advanced lesion. Hispanic individuals had a 36% lower risk of adenomas compared with white individuals. Performance measures including the percentage of procedures with adequate bowel preparation, cecum reached, scope withdrawal time, and adenoma detection rate met quality benchmarks when performed by either faculty or supervised fellows. Project SCOPE's operational strategies demonstrated a feasible method for an academic medical center to provide high-quality screening colonoscopy for low-income populations. © 2013 American Cancer Society.

  17. Demand for Colonoscopy in Colorectal Cancer Screening Using a Quantitative Fecal Immunochemical Test and Age/Sex-Specific Thresholds for Test Positivity.

    PubMed

    Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi

    2018-06-01

    Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.

  18. Factors affecting compliance with colorectal cancer screening among households residing in the largely Haitian community of Little Haiti, Miami-Dade County, Florida: an observational study.

    PubMed

    Wilcox, Meredith Leigh; Acuña, Juan Manuel; de la Vega, Pura Rodriguez; Castro, Grettel; Madhivanan, Purnima

    2015-05-01

    The United States Black population is disproportionately affected by colorectal cancer (CRC) in terms of incidence and mortality. Studies suggest that screening rates are lower among Blacks compared with non-Hispanic Whites (NHWs). However, studies on CRC screening within Black subgroups are lacking. This study examined disparities in blood stool test (BST) compliance and colonoscopy use by race/ethnicity (Haitian, NHW, non-Hispanic Black [NHB], and Hispanic) among randomly selected households in Little Haiti, Miami-Dade County, Florida.This study used cross-sectional, health and wellness data from a random-sample, population-based survey conducted within 951 households in Little Haiti between November 2011 and December 2012. BST compliance and colonoscopy use were self-reported and defined, conservatively, as the use of BST within the past 2 years and the ever use of colonoscopy by any household member. Factors associated with BST compliance and colonoscopy use were identified using logistic regression models. Analyses were restricted to households containing at least 1 member ≥50 years (n = 666).Nearly half of the households were compliant with BST (rate [95% confidence interval (CI)] = 45% [41%-49%]) and completed colonoscopy (rate [95% CI] = 53% [49%-58%]). Compliance with BST was not associated with race/ethnicity (P = 0.76). Factors independently associated with BST compliance included low educational attainment (adjusted odds ratio [AOR] = 0.63, P = 0.03), being single (AOR = 0.47, P = 0.004), retirement (AOR = 1.96, P = 0.01), and the presence of diagnosed health problems (AOR = 1.24, P = 0.01). Colonoscopy use was lower among Haitian households (46%) compared with NHW (63%), NHB (62%), and Hispanic households (54%) (P = 0.002). Factors independently associated with colonoscopy use included identifying as NHB (compared with Haitian) (AOR = 1.80, P = 0.05), being single (AOR = 0.44, P = 0.001), retirement (AOR = 1.86, P = 0.02), lack of continuous insurance (AOR = 0.45, P < 0.001), and the presence of diagnosed health problems (AOR = 1.44, P < 0.001) and physical limitations/disabilities (AOR = 1.88, P = 0.05).Compliance with BST and use of colonoscopy are low within households in the Little Haiti community. Significant disparities in the use of colonoscopy exist between Haitian and NHB households. Barriers and facilitators of colonoscopy within each racial/ethnic group need to be identified as the next step to developing culturally appropriate, community-based interventions aimed at increasing colonoscopy use in this large minority population.

  19. Utilization of Surveillance after Polypectomy in the Medicare Population – A Cohort Study

    PubMed Central

    Lansdorp-Vogelaar, Iris; Fedewa, Stacey; Lin, Chun Chieh; Virgo, Katherine S.; Jemal, Ahmedin

    2014-01-01

    Background Surveillance in patients with previous polypectomy was underused in the Medicare population in 1994. This study investigates whether expansion of Medicare reimbursement for colonoscopy screening in high-risk individuals has reduced the inappropriate use of surveillance. Methods We used Kaplan-Meier analysis to estimate time to surveillance and polyp recurrence rates for Medicare beneficiaries with a colonoscopy with polypectomy between 1998 and 2003 who were followed through 2008 for receipt of surveillance colonoscopy. Generalized Estimating Equations were used to estimate risk factors for: 1) failing to undergo surveillance and 2) polyp recurrence among these individuals. Analyses were stratified into three 2-year cohorts based on baseline colonoscopy date. Results Medicare beneficiaries undergoing a colonoscopy with polypectomy in the 1998–1999 (n = 4,136), 2000–2001 (n = 3,538) and 2002–2003 (n = 4,655) cohorts had respective probabilities of 30%, 26% and 20% (p<0.001) of subsequent surveillance events within 3 years. At the same time, 58%, 52% and 45% (p<0.001) of beneficiaries received a surveillance event within 5 years. Polyp recurrence rates after 5 years were 36%, 30% and 26% (p<0.001) respectively. Older age (≥ 70 years), female gender, later cohort (2000–2001 & 2002–2003), and severe comorbidity were the most important risk factors for failure to undergo a surveillance event. Male gender and early cohort (1998–1999) were the most important risk factors for polyp recurrence. Conclusions Expansion of Medicare reimbursement for colonoscopy screening in high-risk individuals has not reduced underutilization of surveillance in the Medicare population. It is important to take action now to improve this situation, because polyp recurrence is substantial in this population. PMID:25393312

  20. Determination of colonoscopy indication from administrative claims data.

    PubMed

    Ko, Cynthia W; Dominitz, Jason A; Neradilek, Moni; Polissar, Nayak; Green, Pam; Kreuter, William; Baldwin, Laura-Mae

    2014-04-01

    Colonoscopy outcomes, such as polyp detection or complication rates, may differ by procedure indication. To develop methods to classify colonoscopy indications from administrative data, facilitating study of colonoscopy quality and outcomes. We linked 14,844 colonoscopy reports from the Clinical Outcomes Research Initiative, a national repository of endoscopic reports, to the corresponding Medicare Carrier and Outpatient File claims. Colonoscopy indication was determined from the procedure reports. We developed algorithms using classification and regression trees and linear discriminant analysis (LDA) to classify colonoscopy indication. Predictor variables included ICD-9CM and CPT/HCPCS codes present on the colonoscopy claim or in the 12 months prior, patient demographics, and site of colonoscopy service. Algorithms were developed on a training set of 7515 procedures, then validated using a test set of 7329 procedures. Sensitivity was lowest for identifying average-risk screening colonoscopies, varying between 55% and 86% for the different algorithms, but specificity for this indication was consistently over 95%. Sensitivity for diagnostic colonoscopy varied between 77% and 89%, with specificity between 55% and 87%. Algorithms with classification and regression trees with 7 variables or LDA with 10 variables had similar overall accuracy, and generally lower accuracy than the algorithm using LDA with 30 variables. Algorithms using Medicare claims data have moderate sensitivity and specificity for colonoscopy indication, and will be useful for studying colonoscopy quality in this population. Further validation may be needed before use in alternative populations.

  1. [Colonoscopy quality control as a requirement of colorectal cancer screening].

    PubMed

    Quintero, Enrique; Alarcón-Fernández, Onofre; Jover, Rodrigo

    2013-11-01

    The strategies used in population-based colorectal screening strategies culminate in colonoscopy and consequently the success of these programs largely depends on the quality of this diagnostic test. The main factors to consider when evaluating quality are scientific-technical quality, safety, patient satisfaction, and accessibility. Quality indicators allow variability among hospitals, endoscopy units and endoscopists to be determined and can identify those not achieving recommended standards. In Spain, the working group for colonoscopy quality of the Spanish Society of Gastroenterology and the Spanish Society of Gastrointestinal Endoscopy have recently drawn up a Clinical Practice Guideline that contains the available evidence on the quality of screening colonoscopy, as well as the basic requirements that must be met by endoscopy units and endoscopists carrying out this procedure. The implementation of training programs and screening colonoscopy quality controls are strongly recommended to guarantee the success of population-based colorectal cancer screening. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  2. Risk of Metachronous High-Risk Adenomas and Large Serrated Polyps in Individuals With Serrated Polyps on Index Colonoscopy: Data From the New Hampshire Colonoscopy Registry.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Robinson, Christina M; Weiss, Julia E; Amos, Christopher; Srivastava, Amitabh

    2018-01-01

    Surveillance guidelines for serrated polyps (SPs) are based on limited data on longitudinal outcomes of patients. We used the New Hampshire Colonoscopy Registry to evaluate risk of clinically important metachronous lesions associated with SPs detected during index colonoscopies. We collected data from a population-based colonoscopy registry that has been collecting and analyzing data on colonoscopies across the state of New Hampshire since 2004, including rates of adenoma and SP detection. Patients completed a questionnaire to determine demographic characteristics, health history, and risk factors for colorectal cancer, and were followed from index colonoscopy through all subsequent surveillance colonoscopies. Our analyses included 5433 participants (median age, 61 years; 49.7% male) with 2 colonoscopies (median time to surveillance, 4.9 years). We used multivariable logistic regression models to assess effects of index SPs (n = 1016), high-risk adenomas (HRA, n = 817), low-risk adenomas (n = 1418), and no adenomas (n = 3198) on subsequent HRA or large SPs (>1 cm) on surveillance colonoscopy (metachronous lesions). Synchronous SPs, within each index risk group, were assessed for size and by histology. SPs comprise hyperplastic polyps, sessile serrated adenomas/polyps (SSA/Ps), and traditional serrated adenomas. In this study, SSA/Ps and traditional serrated adenomas are referred to collectively as STSAs. HRA and synchronous large SP (odds ratio [OR], 5.61; 95% confidence interval [CI], 1.72-18.28), HRA with synchronous STSA (OR, 16.04; 95% CI, 6.95-37.00), and HRA alone (OR, 3.86; 95% CI, 2.77-5.39) at index colonoscopy significantly increased the risk of metachronous HRA compared to the reference group (no index adenomas or SPs). Large index SPs alone (OR, 14.34; 95% CI, 5.03-40.86) or index STSA alone (OR, 9.70; 95% CI, 3.63-25.92) significantly increased the risk of a large metachronous SP. In an analysis of data from a population-based colonoscopy registry, we found index large SP or index STSA with no index HRA increased risk of metachronous large SPs but not metachronous HRA. HRA and synchronous SPs at index colonoscopy significantly increased risk of metachronous HRA. Individuals with HRA and synchronous large SP or any STSA could therefore benefit from close surveillance. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Faecal haemoglobin concentration influences risk prediction of interval cancers resulting from inadequate colonoscopy quality: analysis of the Taiwanese Nationwide Colorectal Cancer Screening Program

    PubMed Central

    Chiu, Sherry Yueh-Hsia; Chuang, Shu-Ling; Chen, Sam Li-Sheng; Yen, Amy Ming-Fang; Fann, Jean Ching-Yuan; Chang, Dun-Cheng; Lee, Yi-Chia; Wu, Ming-Shiang; Chou, Chu-Kuang; Hsu, Wen-Feng; Chiou, Shu-Ti; Chiu, Han-Mo

    2017-01-01

    Objectives Interval colorectal cancer (CRC) after colonoscopy may affect effectiveness and cost-effectiveness of screening programmes. We aimed to investigate whether and how faecal haemoglobin concentration (FHbC) of faecal immunochemical testing (FIT) affected the risk prediction of interval cancer (IC) caused by inadequate colonoscopy quality in a FIT-based population screening programme. Design From 2004 to 2009, 29 969 subjects underwent complete colonoscopy after positive FIT in the Taiwanese Nationwide CRC Screening Program. The IC rate was traced until the end of 2012. The incidence of IC was calculated in relation to patient characteristics, endoscopy-related factors (such adenoma detection rate (ADR)) and FHbC. Poisson regression analysis was performed to assess the potential risk factors for colonoscopy IC. Results One hundred and sixty-two ICs developed after an index colonoscopy and the estimated incidence was 1.14 per 1000 person-years of observation for the entire cohort. Increased risk of IC was most remarkable in the uptake of colonoscopy in settings with ADR lower than 15% (adjusted relative risk (aRR)=3.09, 95% CI 1.55 to 6.18) and then higher FHbC (μg Hb/g faeces) (100–149: aRR=2.55, 95% CI 1.52 to 4.29, ≥150: aRR=2.74, 95% CI 1.84 to 4.09) with adjustment for older age and colorectal neoplasm detected at baseline colonoscopy. Similar findings were observed for subjects with negative index colonoscopy. Conclusions Colonoscopy ICs arising from FIT-based population screening programmes were mainly influenced by inadequate colonoscopy quality and independently predicted by FHbC that is associated with a priori chance of advanced neoplasm. This finding is helpful for future modification of screening logistics based on FHbC. PMID:26515543

  4. Effectiveness of screening colonoscopy in reducing the risk of death from right and left colon cancer: a large community-based study.

    PubMed

    Doubeni, Chyke A; Corley, Douglas A; Quinn, Virginia P; Jensen, Christopher D; Zauber, Ann G; Goodman, Michael; Johnson, Jill R; Mehta, Shivan J; Becerra, Tracy A; Zhao, Wei K; Schottinger, Joanne; Doria-Rose, V Paul; Levin, Theodore R; Weiss, Noel S; Fletcher, Robert H

    2018-02-01

    Screening colonoscopy's effectiveness in reducing colorectal cancer mortality risk in community populations is unclear, particularly for right-colon cancers, leading to recommendations against its use for screening in some countries. This study aimed to determine whether, among average-risk people, receipt of screening colonoscopy reduces the risk of dying from both right-colon and left-colon/rectal cancers. We conducted a nested case-control study with incidence-density matching in screening-eligible Kaiser Permanente members. Patients who were 55-90 years old on their colorectal cancer death date during 2006-2012 were matched on diagnosis (reference) date to controls on age, sex, health plan enrolment duration and geographical region. We excluded patients at increased colorectal cancer risk, or with prior colorectal cancer diagnosis or colectomy. The association between screening colonoscopy receipt in the 10-year period before the reference date and colorectal cancer death risk was evaluated while accounting for other screening exposures. We analysed 1747 patients who died from colorectal cancer and 3460 colorectal cancer-free controls. Compared with no endoscopic screening, receipt of a screening colonoscopy was associated with a 67% reduction in the risk of death from any colorectal cancer (adjusted OR (aOR)=0.33, 95% CI 0.21 to 0.52). By cancer location, screening colonoscopy was associated with a 65% reduction in risk of death for right-colon cancers (aOR=0.35, CI 0.18 to 0.65) and a 75% reduction for left-colon/rectal cancers (aOR=0.25, CI 0.12 to 0.53). Screening colonoscopy was associated with a substantial and comparably decreased mortality risk for both right-sided and left-sided cancers within a large community-based population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Educational Colonoscopy Video Enhances Bowel Preparation Quality and Comprehension in an Inner City Population.

    PubMed

    Pillai, Ajish; Menon, Radha; Oustecky, David; Ahmad, Asyia

    2017-07-24

    Quality of bowel preparation and patient knowledge remains a major barrier for completing colorectal cancer screening. Few studies have tested unique ways to impact patient understanding centering on interactive computer programs, pictures, and brochures. Two studies explored instructional videos but focused on patient compliance and anxiety as endpoints. Furthermore, excessive video length and content may limit their impact on a broad patient population. No study so far has studied a video's impact on preparation quality and patient understanding of the colonoscopy procedure. We conducted a single blinded prospective study of inner city patients presenting for a first time screening colonoscopy. During their initial visit patients were randomized to watch an instructional colonoscopy video or a video discussing gastroesophageal reflux disease (GERD). All patients watched a 6 minutes long video with the same spokesperson, completed a demographic questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) and were enrolled only if screened within 30 days of their visit. On the day of the colonoscopy, patients completed a 14 question quiz of their knowledge. Blinded endoscopist graded patient preparations based on the Ottawa scale. All authors had access to the study data and reviewed and approved the final manuscript. Among the 104 subjects enrolled in the study, 56 were in the colonoscopy video group, 48 were in GERD video group, and 12 were excluded. Overall, 48% were male and 52% female; 90% of patients had less than a high school education, 76% were African American, and 67% used a 4 L split-dose preparation. There were no differences between either video group with regard to any of the above categories. Comparisons between the 2 groups revealed that the colonoscopy video group had significantly better Ottawa bowel preparation score (4.77 vs. 6.85; P=0.01) than the GERD video group. The colonoscopy video group also had less-inadequate repeat bowel preparations versus the GERD video group (9% vs. 23%; P<0.01). The overall score on the knowledge questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) was significantly higher in the colonoscopy video group as compared with the GERD video group (12.77 vs. 11.08; P<0.001. In all patients the overall quiz score positively correlated with preparation quality (odds ratio, 2.31; confidence interval, 1.35-3.94; P<0.001). Our unique population represented an overwhelmingly under-educated (85% had a high school education or less) and minority group (76% African American). They are one of the most at risk of having multiple barriers such as comprehension and reading difficulties resulting in poor preparation examinations and no shows to procedures. Our instructional video proved to be high yield in this population. The patients assigned to watch the colonoscopy video showed a significant increase in "excellent" grade adequate bowel preparation quality by >23% and a significant decrease in "inadequate" bowel preparations by almost 50%. Our study proves that an educational video can improve both comprehension with regard to all aspects of colonoscopy. ClinicalTrials.gov number, NCT02906969.

  6. Family history and the risk of colorectal cancer: The importance of patients' history of colonoscopy.

    PubMed

    Weigl, Korbinian; Jansen, Lina; Chang-Claude, Jenny; Knebel, Phillip; Hoffmeister, Michael; Brenner, Hermann

    2016-11-15

    Registry-based studies on the risk of colorectal cancer (CRC) for persons with a family history (FH) typically did not control for important covariates, such as history of colonoscopy. We aimed to quantify the association between FH and CRC risk, carefully accounting for potential confounders. We conducted a population-based case-control study in Germany. A total of 4,313 patients with a first diagnosis of CRC (cases) and 3,153 controls recruited from 2003 to 2014 were included. We used multiple logistic regression analyses to assess the association between FH and risk of CRC with odds ratios (OR) and the resulting 95% confidence intervals (95% CI). A total of 582 cases (13.5%) and 321 (10.2%) controls reported a history of CRC in a first-degree relative, which was associated with a 41% increase in risk of CRC (OR: 1.41, 95% CI 1.22-1.63) after adjustment for sex and age. The OR substantially increased to 1.73 (95% CI, 1.48-2.03) after comprehensive adjustment including previous colonoscopies. Irrespective of their FH status, persons with history of colonoscopies had a lower CRC risk compared with persons without previous colonoscopies and without family history (OR: 0.25, 95% CI, 0.22-0.28 for persons without FH and OR 0.45, 95% CI, 0.36-0.56 for persons with FH). In an era of widespread use of colonoscopy, adjusting for previous colonoscopy is therefore crucial for deriving valid estimates of FH-related CRC risk. Colonoscopy reduces the risk of CRC among those with FH far below levels of people with no FH and no colonoscopy. © 2016 UICC.

  7. Culturally targeted patient navigation for increasing african americans' adherence to screening colonoscopy: a randomized clinical trial.

    PubMed

    Jandorf, Lina; Braschi, Caitlyn; Ernstoff, Elizabeth; Wong, Carrie R; Thelemaque, Linda; Winkel, Gary; Thompson, Hayley S; Redd, William H; Itzkowitz, Steven H

    2013-09-01

    Patient navigation has been an effective intervention to increase cancer screening rates. This study focuses on predicting outcomes of screening colonoscopy for colorectal cancer among African Americans using different patient navigation formats. In a randomized clinical trial, patients more than 50 years of age without significant comorbidities were randomized into three navigation groups: peer-patient navigation (n = 181), pro-patient navigation (n = 123), and standard (n = 46). Pro-patient navigations were health care professionals who conducted culturally targeted navigation, whereas peer-patient navigations were community members trained in patient navigation who also discussed their personal experiences with screening colonoscopy. Two assessments gathered sociodemographic, medical, and intrapersonal information. Screening colonoscopy completion rate was 75.7% across all groups with no significant differences in completion between the three study arms. Annual income more than $10,000 was an independent predictor of screening colonoscopy adherence. Unexpectedly, low social influence also predicted screening colonoscopy completion. In an urban African American population, patient navigation was effective in increasing screening colonoscopy rates to 15% above the national average, regardless of patient navigation type or content. Because patient navigation successfully increases colonoscopy adherence, cultural targeting may not be necessary in some populations.

  8. Cardiopulmonary events during primary colonoscopy screening in an average risk population.

    PubMed

    Khalid-de Bakker, C A; Jonkers, D M; Hameeteman, W; de Ridder, R J; Masclee, A A; Stockbrügger, R W

    2011-04-01

    Large colorectal cancer screening studies using primary colonoscopy have reported a low risk of major complications. Studies on diagnostic and therapeutic colonoscopy have pointed to a frequent occurrence of(minor) cardiopulmonary events, and with the steady increase of colonoscopy screening, it is important to investigate their occurrence in colonoscopy screening. This study describes the frequency of bradycardia(pulse rate <60 min-1), hypotension (systolic blood pressure(SB P) <90 mmHg), hypoxaemia (blood oxygenation, SaO2<90%) and ECG changes during colonoscopy screening in an average-risk population (hospital personnel, n=214,mean age 54.0±3.8, 39.3% male), without significant comorbidity) and aims at identifying subject-related and/or endoscopic factors associated with their occurrence. All data were collected prospectively. During 214 consecutive primary screening colonoscopies under conscious sedation(midazolam and pethidine), on top of pulse rate and SaO2,blood pressure and a three-channel ECG were recorded every five minutes. No major complications or relevant ECG changes occurred. Hypoxaemia occurred in 119 (55.6%),hypotension in 19 (8.9%) and bradycardia in 12 subjects(5.6%). In multivariate analysis, the sedation level 3 increased the risk of hypoxaemia (OR 4.8, CI 1.7-13.7), and incomplete colonoscopy (OR 5.3, CI 1.6-18.1) was associated with hypotension. Subjects with bradycardia had a longer mean procedure time (38±12 vs. 29±12 min, p<0.05), which did not turn out as a risk factor in a multivariate analysis. Mainly procedure-related and not subject-related factors were found to be associated with the occurrence of cardiopulmonary events in primary colonoscopy screening in this relatively healthy screening population.

  9. Is Travel Time to Colonoscopy Associated With Late-Stage Colorectal Cancer Among Medicare Beneficiaries in Iowa?

    PubMed

    Charlton, Mary E; Matthews, Kevin A; Gaglioti, Anne; Bay, Camden; McDowell, Bradley D; Ward, Marcia M; Levy, Barcey T

    2016-09-01

    Colorectal cancer (CRC) screening has been shown to decrease the incidence of late-stage colorectal cancer, yet a substantial proportion of Americans do not receive screening. Those in rural areas may face barriers to colonoscopy services based on travel time, and previous studies have demonstrated lower screening among rural residents. Our purpose was to assess factors associated with late-stage CRC, and specifically to determine if longer travel time to colonoscopy was associated with late-stage CRC among an insured population in Iowa. SEER-Medicare data were used to identify individuals ages 65 to 84 years old diagnosed with CRC in Iowa from 2002 to 2009. The distance between the centroid of the ZIP code of residence and the ZIP code of colonoscopy was computed for each individual who had continuous Medicare fee-for-service coverage for a 3- to 4-month period prior to diagnosis, and a professional claim for colonoscopy within that time frame. Demographic characteristics and travel times were compared between those diagnosed with early- versus late-stage CRC. Also, demographic differences between those who had colonoscopy claims identified within 3-4 months prior to diagnosis (81%) were compared to patients with no colonoscopy claims identified (19%). A total of 5,792 subjects met inclusion criteria; 31% were diagnosed with early-stage versus 69% with late-stage CRC. Those divorced or widowed (vs married) were more likely to be diagnosed with late-stage CRC (OR: 1.20, 95% CI: 1.06-1.37). Travel time was not associated with diagnosis of late-stage CRC. Among a Medicare-insured population, there was no relationship between travel time to colonoscopy and disease stage at diagnosis. It is likely that factors other than distance to colonoscopy present more pertinent barriers to screening in this insured population. Additional research should be done to determine reasons for nonadherence to screening among those with access to CRC screening services, given that over two-thirds of these insured individuals were diagnosed with late-stage CRC. © 2015 National Rural Health Association.

  10. Colorectal Cancer Screening Based on Age and Gender

    PubMed Central

    Wong, Martin C.S.; Ching, Jessica Y.L.; Chan, Victor C.W.; Lam, Thomas Y.T.; Luk, Arthur K.C.; Wong, Sunny H.; Ng, Siew C.; Ng, Simon S.M.; Wu, Justin C.Y.; Chan, Francis K.L.; Sung, Joseph J.Y.

    2016-01-01

    Abstract We evaluated whether age- and gender-based colorectal cancer screening is cost-effective. Recent studies in the United States identified age and gender as 2 important variables predicting advanced proximal neoplasia, and that women aged <60 to 70 years were more suited for sigmoidoscopy screening due to their low risk of proximal neoplasia. Yet, quantitative assessment of the incremental benefits, risks, and cost remains to be performed. Primary care screening practice (2008–2015). A Markov modeling was constructed using data from a screening cohort. The following strategies were compared according to the Incremental Cost Effectiveness Ratio (ICER) for 1 life-year saved: flexible sigmoidoscopy (FS) 5 yearly; colonoscopy 10 yearly; FS for each woman at 50- and 55-year old followed by colonoscopy at 60- and 70-year old; FS for each woman at 50-, 55-, 60-, and 65-year old followed by colonoscopy at 70-year old; FS for each woman at 50-, 55-, 60-, 65-, and 70-year old. All male subjects received colonoscopy at 50-, 60-, and 70-year old under strategies 3 to 5. From a hypothetical population of 100,000 asymptomatic subjects, strategy 2 could save the largest number of life-years (4226 vs 2268 to 3841 by other strategies). When compared with no screening, strategy 5 had the lowest ICER (US$42,515), followed by strategy 3 (US$43,517), strategy 2 (US$43,739), strategy 4 (US$47,710), and strategy 1 (US$56,510). Strategy 2 leads to the highest number of bleeding and perforations, and required a prohibitive number of colonoscopy procedures. Strategy 5 remains the most cost-effective when assessed with a wide range of deterministic sensitivity analyses around the base case. From the cost effectiveness analysis, FS for women and colonoscopy for men represent an economically favorable screening strategy. These findings could inform physicians and policy-makers in triaging eligible subjects for risk-based screening, especially in countries with limited colonoscopic resources. Future research should study the acceptability, feasibility, and feasibility of this risk-based strategy in different populations. PMID:26962772

  11. Colonoscopy screening for colorectal cancer: the outcomes of two recruitment methods.

    PubMed

    Corbett, Mike; Chambers, Sharon L; Shadbolt, Bruce; Hillman, Lybus C; Taupin, Doug

    2004-10-18

    To determine the response to colorectal cancer (CRC) screening by colonoscopy, through direct invitation or through invitation by general practitioners. Two-way comparison of randomised population sampling versus cluster sampling of a representative general practice population in the Australian Capital Territory, May 2002 to January 2004. Invitation to screen, assessment for eligibility, interview, and colonoscopy. 881 subjects aged 55-74 years were invited to screen: 520 from the electoral roll (ER) sample and 361 from the general practice (GP) cluster sample. Response rate, participation rate, and rate of adenomatous polyps in the screened group. Participation was similar in the ER arm (35.1%; 95% CI, 30.2%-40.3%) and the GP arm (40.1%; 95% CI, 29.2%-51.0%) after correcting for ineligibility, which was higher in the ER arm. Superior eligibility in the GP arm was offset by the labour of manual record review. Response rates after two invitations were similar for the two groups (ER arm: 78.8%; 95% CI, 75.1%-82.1%; GP arm: 81.7%; 95% CI, 73.8%-89.6%). Overall, 53.4% ineligibility arose from having a colonoscopy in the past 10 years (ER arm, 98/178; GP arm, 42/84). Of 231 colonoscopies performed, 229 were complete, with 32% of subjects screened having adenomatous polyps. Colonoscopy-based CRC screening yields similar response and participation rates with either random population sampling or general practice cluster sampling, with population sampling through the electoral roll providing greater ease of recruitment.

  12. Low-serum GTA-446 anti-inflammatory fatty acid levels as a new risk factor for colon cancer.

    PubMed

    Ritchie, Shawn A; Tonita, Jon; Alvi, Riaz; Lehotay, Denis; Elshoni, Hoda; Myat, Su-; McHattie, James; Goodenowe, Dayan B

    2013-01-15

    Gastrointestinal tract acid-446 (GTA-446) is a long-chain polyunsaturated fatty acid present in the serum. A reduction of GTA-446 levels in colorectal cancer (CRC) patients has been reported previously. Our study compared GTA-446 levels in subjects diagnosed with CRC at the time of colonoscopy to the general population. Serum samples and pathology data were collected from 4,923 representative subjects undergoing colonoscopy and from 964 subjects from the general population. Serum GTA-446 levels were determined using a triple-quadrupole tandem mass spectrometry method. A low-serum GTA-446 level was based on the bottom tenth percentile of subjects with low risk based on age (40-49 years old) in the general population. Eighty-six percent of newly diagnosed CRC subjects (87% for stages 0-II and 85% for stages III-IV) showed low-serum GTA-446 levels. A significant increase in the CRC incidence rate with age was observed in subjects with low GTA-446 levels (p = 0.019), but not in subjects with normal levels (p = 0.86). The relative risk of CRC given a low GTA-446 level was the highest for subjects under age 50 (10.1, 95% confidence interval [C.I.] = 6.4-16.4 in the reference population, and 7.7, 95% C.I. = 4.4-14.1 in the colonoscopy population, both p < 0.0001), and declined with age thereafter. The CRC incidence rate in subjects undergoing colonoscopy with low GTA-446 levels was over six times higher than for subjects with normal GTA-446 levels and twice that of subjects with gastrointestinal symptoms. The results show that a low-serum GTA-446 level is a significant risk factor for CRC, and a sensitive predictor of early-stage disease. Copyright © 2012 UICC.

  13. Evidence-based recommendations for bowel cleansing before colonoscopy in children: a report from a national working group.

    PubMed

    Turner, D; Levine, A; Weiss, B; Hirsh, A; Shamir, R; Shaoul, R; Berkowitz, D; Bujanover, Y; Cohen, S; Eshach-Adiv, O; Jamal, Gera; Kori, M; Lerner, A; On, A; Rachman, L; Rosenbach, Y; Shamaly, H; Shteyer, E; Silbermintz, A; Yerushalmi, B

    2010-12-01

    There are no current recommendations for bowel cleansing before colonoscopy in children. The Israeli Society of Pediatric Gastroenterology and Nutrition (ISPGAN) established an iterative working group to formulate evidence-based guidelines for bowel cleansing in children prior to colonoscopy. Data were collected by systematic review of the literature and via a national-based survey of all endoscopy units in Israel. Based on the strength of evidence, the Committee reached consensus on six recommended protocols in children. Guidelines were finalized after an open audit of ISPGAN members. Data on 900 colonoscopies per year were accrued, which represents all annual pediatric colonoscopies performed in Israel. Based on the literature review, the national survey, and the open audit, several age-stratified pediatric cleansing protocols were proposed: two PEG-ELS protocols (polyethylene-glycol with electrolyte solution); Picolax-based protocol (sodium picosulphate with magnesium citrate); sodium phosphate protocol (only in children over the age of 12 years who are at low risk for renal damage); stimulant laxative-based protocol (e. g. bisacodyl); and a PEG 3350-based protocol. A population-based analysis estimated that the acute toxicity rate of oral sodium phosphate is at most 3/7320 colonoscopies (0.041 %). Recommendations on diet and enema use are provided in relation to each proposed protocol. There is no ideal bowel cleansing regimen and, thus, various protocols are in use. We propose several evidence-based protocols to optimize bowel cleansing in children prior to colonoscopy and minimize adverse events. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Screening for Colorectal Cancer With Fecal Immunochemical Testing With and Without Postpolypectomy Surveillance Colonoscopy: A Cost-Effectiveness Analysis.

    PubMed

    Greuter, Marjolein J E; de Klerk, Clasine M; Meijer, Gerrit A; Dekker, Evelien; Coupé, Veerle M H

    2017-10-17

    Population-based screening to prevent colorectal cancer (CRC) death is effective, but the effectiveness of postpolypectomy surveillance is unclear. To evaluate the additional benefit in terms of cost-effectiveness of colonoscopy surveillance in a screening setting. Microsimulation using the ASCCA (Adenoma and Serrated pathway to Colorectal CAncer) model. Dutch CRC screening program and published literature. Asymptomatic persons aged 55 to 75 years without a prior CRC diagnosis. Lifetime. Health care payer. Fecal immunochemical test (FIT) screening with colonoscopy surveillance performed according to the Dutch guideline was simulated. The comparator was no screening or surveillance. FIT screening without colonoscopy surveillance and the effect of extending surveillance intervals were also evaluated. CRC burden, colonoscopy demand, life-years, and costs. FIT screening without surveillance reduced CRC mortality by 50.4% compared with no screening or surveillance. Adding surveillance to FIT screening reduced mortality by an additional 1.7% to 52.1% but increased lifetime colonoscopy demand by 62% (from 335 to 543 colonoscopies per 1000 persons) at an additional cost of €68 000, for an increase of 0.9 life-year. Extending the surveillance intervals to 5 years reduced CRC mortality by 51.8% and increased colonoscopy demand by 42.7% compared with FIT screening without surveillance. In an incremental analysis, incremental cost-effectiveness ratios (ICERs) for screening plus surveillance exceeded the Dutch willingness-to-pay threshold of €36 602 per life-year gained. When using a parameter set representing low colorectal lesion prevalence or when colonoscopy costs were halved or colorectal lesion incidence was doubled, screening plus surveillance became cost-effective compared with screening without surveillance. Limited data on FIT performance and background CRC risk in the surveillance population. Adding surveillance to FIT screening is not cost-effective based on the Dutch ICER threshold and substantially increases colonoscopy demand. Extending surveillance intervals to 5 years would decrease colonoscopy demand without substantial loss of effectiveness. Alpe d'HuZes, Dutch Cancer Society, and Stand Up To Cancer.

  15. Endoscopic detection rate of sessile serrated lesions in Lynch syndrome patients is comparable with an age- and gender-matched control population: case-control study with expert pathology review.

    PubMed

    Vleugels, Jasper L A; Sahin, Husna; Hazewinkel, Yark; Koens, Lianne; van den Berg, Jose G; van Leerdam, Monique E; Dekker, Evelien

    2018-05-01

    Carcinogenesis in Lynch syndrome involves fast progression of adenomas to colorectal cancer (CRC) because of microsatellite instability. The role of sessile serrated lesions (SSLs) and the serrated neoplasia pathway in these patients is unknown. The aim of this matched case-control study was to compare endoscopic detection rates and distribution of SSLs in Lynch syndrome patients with a matched control population. We collected data of Lynch syndrome patients with a proven germline mutation who underwent colonoscopy between January 2011 and April 2016 in 2 tertiary referral hospitals. Control subjects undergoing elective colonoscopy from 2011 and onward for symptoms or surveillance were selected from a prospectively collected database. Patients were matched 1:1 for age, gender, and index versus surveillance colonoscopy. An expert pathology review of serrated polyps was performed. The primary outcomes included the detection rates and distribution of SSLs. We identified 321 patients with Lynch syndrome who underwent at least 1 colonoscopy. Of these, 223 Lynch syndrome patients (mean age, 49.3; 59% women; index colonoscopy, 56%) were matched to 223 control subjects. SSLs were detected in 7.6% (95% confidence interval, 4.8-11.9) of colonoscopies performed in Lynch syndrome patients and in 6.7% (95% confidence interval, 4.1-10.8) of control subjects (P = .86). None of the detected SSLs in Lynch syndrome patients contained dysplasia. The detection rate of SSLs in Lynch syndrome patients undergoing colonoscopy is comparable with a matched population. These findings suggest that the role of the serrated neoplasia pathway in CRC development in Lynch syndrome seems to be comparable with that in the general population. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  16. The intelligent, painless, "germ-free" colonoscopy: A Columbus' egg for increasing population adherence to colorectal cancer screening?

    PubMed

    Perri, Francesco; Iacobellis, Angelo; Gentile, Marco; Tumino, Emanuele; Andriulli, Angelo

    2010-12-01

    Colorectal cancer (CRC) represents a major cause of morbidity and mortality. Although it is widely accepted that CRC screening in average risk populations lowers CRC incidence and mortality, a disappointedly low adherence rate to both faecal occult blood testing and colonoscopy-based screening programs has been observed in Italy and in other European countries. Main reasons for the low acceptance of colonoscopy-based CRC screening has been ascribed to lack of recommendations given by general practitioners, fear of discomfort or complications, embarrassment, and avoidance of unpleasant preparation. New advances in endoscopic technology such as colon capsule and robotic colonoscopy might represent the ideal tool for CRC screening since they reduce or eliminate procedure-related pain and discomfort. Moreover, no disinfection between procedures is required. Motion of the new probes along the gastrointestinal tract is achieved either in passive modality by utilizing the gut peristalsis (colon capsule) or in active "intelligent" modality by means of computer-assisted propulsion (robotic colonoscopy). In this review, the preliminary clinical results obtained with the new devices are summarized. It is expected that the new instruments will be soon available in clinical practice with the hope of increasing adherence to CRC screening programs. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Sending family history questionnaires to patients before a colonoscopy improves genetic counseling for hereditary colorectal cancer.

    PubMed

    Kessels, Koen; Eisinger, Joey D; Letteboer, Tom G; Offerhaus, G Johan A; Siersema, Peter D; Moons, Leon M G

    2017-06-01

    To investigate whether sending a family history questionnaire to patients prior to undergoing colonoscopy results in an increased availability of family history and better genetic counseling. A questionnaire was mailed to patients before they underwent outpatient colonoscopy at a university hospital in 2013. These patients' additional characteristics and referral for genetic evaluation were retrieved from the electronic medical records. Patients undergoing inpatient coloboscopy, with confirmed hereditary colorectal cancer (CRC) or inflammatory bowel disease were excluded. All study patients from 2010 to 2013 were matched with the database of the genetics department to determine who consulted a geneticist. A total of 6163 patients underwent colonoscopy from 2010 to 2013. Of 1421 who underwent colonoscopy in 2013, 53 (3.7%) consulted a geneticist, while 75 (1.6%) of 4742 patients undergoing colonoscopy between 2010 and 2012 did so (P < 0.01). A total of 974 patients undergoing colonoscopy in 2013 were included to evaluate the completed questionnaire. Of these, 282 (29.0%) completed the questionnaire. Family history was not recorded in the electronic medical records of 393 (40.3%). In 129 (32.8%), family history was obtained from the completed questionnaire. In 2013, 49 (60.5%) out of 81 patients referred for genetic counseling were referred based on their family history. Eight (9.9%) patients were referred based on the completed questionnaire. Screening for hereditary CRC in a population undergoing outpatient colonoscopy with a questionnaire sent by mail resulted in an increased availability of family histories and genetic counseling. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  18. Impact of comorbidity on colorectal cancer screening cost-effectiveness study in diabetic populations.

    PubMed

    Dinh, Tuan A; Alperin, Peter; Walter, Louise C; Smith, Robert

    2012-06-01

    Although comorbidity has been shown to affect the benefits and risks of colorectal cancer (CRC) screening, it has not been accounted for in prior cost-effectiveness analyses of CRC screening. To evaluate the impact of diagnosis of diabetes mellitus, a highly prevalent comorbidity in U.S. adults aged 50 and older, on health and economic outcomes of CRC screening. Cost-effectiveness analysis using an integrated modeling framework. Derived from basic and epidemiologic studies, clinical trials, cancer registries, and a colonoscopy database. U.S. 50-year-old population. Lifetime. Costs are based on Medicare reimbursement rates. Colonoscopy screening at ten-year intervals, beginning at age 50, and discontinued after age 50, 60, 70, 80 or death. Health outcomes and cost effectiveness. Diabetes diagnosis significantly affects cost-effectiveness of CRC screening. For the same CRC screening strategy, a person without diabetes at age 50 gained on average 0.07-0.13 life years more than a person diagnosed with diabetes at age 50 or younger. For a population of 1,000 patients diagnosed with diabetes at baseline, increasing stop age from 70 years to 80 years increased quality-adjusted life years (QALYs) gained by 0.3, with an incremental cost-effectiveness ratio of $206,671/QALY. The corresponding figures for 1,000 patients without diabetes are 2.3 QALYs and $46,957/QALY. Cost-effectiveness results are sensitive to cost of colonoscopy and adherence to colonoscopy screening. Results depend on accuracy of model assumptions. Benefits of CRC screening differ substantially for patients with and without diabetes. Screening for CRC in patients diagnosed with diabetes at age 50 or younger is not cost-effective beyond age 70. Screening recommendations should be individualized based on the presence of comorbidities.

  19. Association between Diverticular Disease and Pre-Neoplastic Colorectal Lesions in an Urban African-American Population.

    PubMed

    Ashktorab, Hassan; Panchal, Heena; Shokrani, Babak; Paydar, Mansour; Sanderson, Andrew; Lee, Edward L; Begum, Rehana; Haidary, Tahmineh; Laiyemo, Adeyinka O; McDonald-Pinkett, Shelly; Brim, Hassan; Nouraie, Mehdi

    2015-01-01

    It is unclear whether there is a shared pathway in the development of diverticular disease (DD) and potentially neoplastic colorectal lesions since both diseases are found in similar age groups and populations. To determine the association between DD and colorectal pre-neoplastic lesions in an African-American urban population. Data from 1986 patients who underwent colonoscopy at the Howard University Hospital from January 2012 through December 2012 were analyzed for this study. The presence of diverticula and polyps was recorded using colonoscopy reports. Polyps were further classified into adenoma or hyperplastic polyp based on histopathology reports. Multiple logistic regression was done to analyze the association between DD and colonic lesions. Of the 1986 study subjects, 1,119 (56%) were females, 35% had DD and 56% had at least one polyp. There was a higher prevalence of polyps (70 vs. 49%; OR = 2.3; 95% CI: 1.9-2.8) and adenoma (43 vs. 25%; OR = 2.0; 95% CI: 1.7-2.5) in the diverticular vs. non-diverticula patients. Among patients who underwent screening colonoscopy, the presence of diverticulosis was associated with increased odds of associated polyps (OR = 9.9; 95% CI: 5.4-16.8) and adenoma (OR = 5.1; 95% CI: 3.4-7.8). Patients with DD are more likely to harbor colorectal lesions. These findings call for more vigilance on the part of endoscopists during colonoscopy in patients known to harbor colonic diverticula. © 2015 S. Karger AG, Basel.

  20. A centrally generated primary care physician audit report does not improve colonoscopy uptake after a positive result on a fecal occult blood test in Ontario's ColonCancerCheck program.

    PubMed

    Stock, D; Rabeneck, L; Baxter, N N; Paszat, L F; Sutradhar, R; Yun, L; Tinmouth, J

    2017-02-01

    Timely follow-up of fecal occult blood screening with colonoscopy is essential for achieving colorectal cancer mortality reduction. In the present study, we evaluated the effectiveness of centrally generated, physician-targeted audit and feedback to improve colonoscopy uptake after a positive fecal occult blood test (fobt) result within Ontario's population-wide ColonCancerCheck Program. This prospective cohort study used data sets from Ontario's ColonCancerCheck Program (2008-2011) that were linked to provincial administrative health databases. Cox proportional hazards regression was used to estimate the effect of centralized, physician-targeted audit and feedback on colonoscopy uptake in an Ontario-wide fobt-positive cohort. A mailed physician audit and feedback report identifying individuals outstanding for colonoscopy for 3 or more months after a positive fobt result did not increase the likelihood of colonoscopy uptake (hazard ratio: 0.95; 95% confidence interval: 0.79 to 1.13). Duration of positive fobt status was strongly inversely associated with the hazard of follow-up colonoscopy ( p for linear trend: <0.001). In a large population-wide setting, centralized tracking in the form of physician-targeted mailed audit and feedback reports does not improve colonoscopy uptake for screening participants with a positive fobt result outstanding for 3 or more months. Mailed physician-targeted screening audit and feedback reports alone are unlikely to improve compliance with follow-up colonoscopy in Ontario. Other interventions such as physician audits or automatic referrals, demonstrated to be effective in other jurisdictions, might be warranted.

  1. Neighborhood Socioeconomic Status and Use of Colonoscopy in an Insured Population – A Retrospective Cohort Study

    PubMed Central

    Doubeni, Chyke A.; Jambaulikar, Guruprasad D.; Fouayzi, Hassan; Robinson, Scott B.; Gunter, Margaret J.; Field, Terry S.; Roblin, Douglas W.; Fletcher, Robert H.

    2012-01-01

    Background Low-socioeconomic status (SES) is associated with a higher colorectal cancer (CRC) incidence and mortality. Screening with colonoscopy, the most commonly used test in the US, has been shown to reduce the risk of death from CRC. This study examined if, among insured persons receiving care in integrated healthcare delivery systems, differences exist in colonoscopy use according to neighborhood SES. Methods We assembled a retrospective cohort of 100,566 men and women, 50–74 years old, who had been enrolled in one of three US health plans for ≥1 year on January 1, 2000. Subjects were followed until the date of first colonoscopy, date of disenrollment from the health plan, or December 31, 2007, whichever occurred first. We obtained data on colonoscopy use from administrative records. We defined screening colonoscopy as an examination that was not preceded by gastrointestinal conditions in the prior 6-month period. Neighborhood SES was measured using the percentage of households in each subject's census-tract with an income below 1999 federal poverty levels based on 2000 US census data. Analyses, adjusted for demographics and comorbidity index, were performed using Weibull regression models. Results The average age of the cohort was 60 years and 52.7% were female. During 449,738 person-years of follow-up, fewer subjects in the lowest SES quartile (Q1) compared to the highest quartile (Q4) had any colonoscopy (26.7% vs. 37.1%) or a screening colonoscopy (7.6% vs. 13.3%). In regression analyses, compared to Q4, subjects in Q1 were 16% (adjusted HR = 0.84, 95% CI: 0.80–0.88) less likely to undergo any colonoscopy and 30%(adjusted HR = 0.70, CI: 0.65–0.75) less likely to undergo a screening colonoscopy. Conclusion People in lower-SES neighborhoods are less likely to undergo a colonoscopy, even among insured subjects receiving care in integrated healthcare systems. Removing health insurance barriers alone is unlikely to eliminate disparities in colonoscopy use. PMID:22567154

  2. Low-serum GTA-446 anti-inflammatory fatty acid levels as a new risk factor for colon cancer

    PubMed Central

    Ritchie, Shawn A; Tonita, Jon; Alvi, Riaz; Lehotay, Denis; Elshoni, Hoda; Myat, Su-; McHattie, James; Goodenowe, Dayan B

    2013-01-01

    Gastrointestinal tract acid-446 (GTA-446) is a long-chain polyunsaturated fatty acid present in the serum. A reduction of GTA-446 levels in colorectal cancer (CRC) patients has been reported previously. Our study compared GTA-446 levels in subjects diagnosed with CRC at the time of colonoscopy to the general population. Serum samples and pathology data were collected from 4,923 representative subjects undergoing colonoscopy and from 964 subjects from the general population. Serum GTA-446 levels were determined using a triple-quadrupole tandem mass spectrometry method. A low-serum GTA-446 level was based on the bottom tenth percentile of subjects with low risk based on age (40–49 years old) in the general population. Eighty-six percent of newly diagnosed CRC subjects (87% for stages 0–II and 85% for stages III–IV) showed low-serum GTA-446 levels. A significant increase in the CRC incidence rate with age was observed in subjects with low GTA-446 levels (p = 0.019), but not in subjects with normal levels (p = 0.86). The relative risk of CRC given a low GTA-446 level was the highest for subjects under age 50 (10.1, 95% confidence interval [C.I.] = 6.4–16.4 in the reference population, and 7.7, 95% C.I. = 4.4–14.1 in the colonoscopy population, both p < 0.0001), and declined with age thereafter. The CRC incidence rate in subjects undergoing colonoscopy with low GTA-446 levels was over six times higher than for subjects with normal GTA-446 levels and twice that of subjects with gastrointestinal symptoms. The results show that a low-serum GTA-446 level is a significant risk factor for CRC, and a sensitive predictor of early-stage disease. PMID:22696299

  3. Development and validation of an algorithm to complete colonoscopy using standard endoscopes in patients with prior incomplete colonoscopy

    PubMed Central

    Rogers, Melinda C.; Gawron, Andrew; Grande, David; Keswani, Rajesh N.

    2017-01-01

    Background and study aims  Incomplete colonoscopy may occur as a result of colon angulation (adhesions or diverticulosis), endoscope looping, or both. Specialty endoscopes/devices have been shown to successfully complete prior incomplete colonoscopies, but may not be widely available. Radiographic or other image-based evaluations have been shown to be effective but may miss small or flat lesions, and colonoscopy is often still indicated if a large lesion is identified. The purpose of this study was to develop and validate an algorithm to determine the optimum endoscope to ensure completion of the examination in patients with prior incomplete colonoscopy. Patients and methods  This was a prospective cohort study of 175 patients with prior incomplete colonoscopy who were referred to a single endoscopist at a single academic medical center over a 3-year period from 2012 through 2015. Colonoscopy outcomes from the initial 50 patients were used to develop an algorithm to determine the optimal standard endoscope and technique to achieve cecal intubation. The algorithm was validated on the subsequent 125 patients. Results  The overall repeat colonoscopy success rate using a standard endoscope was 94 %. The initial standard endoscope specified by the algorithm was used and completed the colonoscopy in 90 % of patients. Conclusions  This study identifies an effective strategy for completing colonoscopy in patients with prior incomplete examination, using widely available standard endoscopes and an algorithm based on patient characteristics and reasons for prior incomplete colonoscopy. PMID:28924595

  4. Feasible economic strategies to improve screening compliance for colorectal cancer in Korea

    PubMed Central

    Park, Sang Min; Yun, Young Ho; Kwon, Soonman

    2005-01-01

    AIM: While colorectal cancer (CRC) is an ideal target for population screening, physician and patient attitudes contribute to low levels of screening uptake. This study was carried out to find feasible economic strategies to improve the CRC screening compliance in Korea. METHODS: The natural history of a simulated cohort of 50-year-old Korean in the general population was modeled with CRC screening until the age of 80 years. Cases of positive results were worked up with colonoscopy. After polypectomy, colonoscopy was repeated every 3 years. Baseline screening compliance without insurance coverage by the national health insurance (NHI) was assumed to be 30%. If NHI covered the CRC screening or the reimbursement of screening to physicians increased, the compliance was assumed to increase. We evaluated 16 different CRC screening strategies based on Markov model. RESULTS: When the NHI did not cover the screening and compliance was 30%, non-dominated strategies were colonoscopy every 5 years (COL5) and colonoscopy every 3 years (COL3). In all scenarios of various compliance rates with raised coverage of the NHI and increased reimbursement of colonoscopy, COL10, COL5 and COL3 were non-dominated strategies, and COL10 had lower or minimal incremental medical cost and financial burden on the NHI than the strategy of no screening. These results were stable with sensitivity analyses. CONCLUSION: Economic strategies for promoting screening compliance can be accompanied by expanding insurance coverage by the NHI and by increasing reimbursement for CRC screening to providers. COL10 was a cost-effective and cost saving screening strategy for CRC in Korea. PMID:15786532

  5. Colorectal and interval cancers of the Colorectal Cancer Screening Program in the Basque Country (Spain)

    PubMed Central

    Portillo, Isabel; Arana-Arri, Eunate; Idigoras, Isabel; Bilbao, Isabel; Martínez-Indart, Lorea; Bujanda, Luis; Gutierrez-Ibarluzea, Iñaki

    2017-01-01

    AIM To assess proportions, related conditions and survival of interval cancer (IC). METHODS The programme has a linkage with different clinical databases and cancer registers to allow suitable evaluation. This evaluation involves the detection of ICs after a negative faecal inmunochemical test (FIT), interval cancer FIT (IC-FIT) prior to a subsequent invitation, and the detection of ICs after a positive FIT and confirmatory diagnosis without colorectal cancer (CRC) detected and before the following recommended colonoscopy, IC-colonoscopy. We conducted a retrospective observational study analyzing from January 2009 to December 2015 1193602 invited people onto the Programme (participation rate of 68.6%). RESULTS Two thousand five hundred and eighteen cancers were diagnosed through the programme, 18 cases of IC-colonoscopy were found before the recommended follow-up (43542 colonoscopies performed) and 186 IC-FIT were identified before the following invitation of the 769200 negative FITs. There was no statistically significant relation between the predictor variables of ICs with sex, age and deprivation index, but there was relation between location and stage. Additionally, it was observed that there was less risk when the location was distal rather than proximal (OR = 0.28, 95%CI: 0.20-0.40, P < 0.0001), with no statistical significance when the location was in the rectum as opposed to proximal. When comparing the screen-detected cancers (SCs) with ICs, significant differences in survival were found (P < 0.001); being the 5-years survival for SCs 91.6% and IC-FIT 77.8%. CONCLUSION These findings in a Population Based CRC Screening Programme indicate the need of population-based studies that continue analyzing related factors to improve their detection and reducing harm. PMID:28487610

  6. Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels.

    PubMed

    Tapia-Siles, Silvia C; Coleman, Stuart; Cuschieri, Alfred

    2016-02-01

    Previous reports have described several candidates, which have the potential to replace colonoscopy, but to date, there is still no device capable of fully replacing flexible colonoscopy in the management of colonic disorders and for mass adult population screening for asymptomatic colorectal cancer. NASA developed the TRL methodology to describe and define the stages of development before use and marketing of any device. The definitions of the TRLS used in the present review are those formulated by "The US Department of Defense Technology Readiness Assessment Guidance" but adapted to micro-robots for colonoscopy. All the devices included are reported in scientific literature. They were identified by a systematic search in Web of Science, PubMed and IEEE Xplore amongst other sources. Devices that clearly lack the potential for full replacement of flexible colonoscopy were excluded. The technological salient features of all the devices included for assessment are described briefly, with particular focus on device propulsion. The devices are classified according to the TRL criteria based on the reported information. An analysis is next undertaken of the characteristics and salient features of the devices included in the review: wireless/tethered devices, data storage-transmission and navigation, additional functionality, residual technology challenges and clinical and socio-economical needs. Few devices currently possess the required functionality and performance to replace the conventional colonoscopy. The requirements, including functionalities which favour the development of a micro-robot platform to replace colonoscopy, are highlighted.

  7. Cost-effectiveness of competing strategies for management of recurrent Clostridium difficile infection: a decision analysis.

    PubMed

    Konijeti, Gauree G; Sauk, Jenny; Shrime, Mark G; Gupta, Meera; Ananthakrishnan, Ashwin N

    2014-06-01

    Clostridium difficile infection (CDI) is an important cause of morbidity and healthcare costs, and is characterized by high rates of disease recurrence. The cost-effectiveness of newer treatments for recurrent CDI has not been examined, yet would be important to inform clinical practice. The aim of this study was to analyze the cost effectiveness of competing strategies for recurrent CDI. We constructed a decision-analytic model comparing 4 treatment strategies for first-line treatment of recurrent CDI in a population with a median age of 65 years: metronidazole, vancomycin, fidaxomicin, and fecal microbiota transplant (FMT). We modeled up to 2 additional recurrences following the initial recurrence. We assumed FMT delivery via colonoscopy as our base case, but conducted sensitivity analyses based on different modes of delivery. Willingness-to-pay threshold was set at $50 000 per quality-adjusted life-year. At our base case estimates, initial treatment of recurrent CDI using FMT colonoscopy was the most cost-effective strategy, with an incremental cost-effectiveness ratio of $17 016 relative to oral vancomycin. Fidaxomicin and metronidazole were both dominated by FMT colonoscopy. On sensitivity analysis, FMT colonoscopy remained the most cost-effective strategy at cure rates >88.4% and CDI recurrence rates <14.9%. Fidaxomicin required a cost <$1359 to meet our cost-effectiveness threshold. In clinical settings where FMT is not available or applicable, the preferred strategy appears to be initial treatment with oral vancomycin. In this decision analysis examining treatment strategies for recurrent CDI, we demonstrate that FMT colonoscopy is the most cost-effective initial strategy for management of recurrent CDI.

  8. At what costs will screening with CT colonography be competitive? A cost-effectiveness approach.

    PubMed

    Lansdorp-Vogelaar, Iris; van Ballegooijen, Marjolein; Zauber, Ann G; Boer, Rob; Wilschut, Janneke; Habbema, J Dik F

    2009-03-01

    The costs of computed tomographic colonography (CTC) are not yet established for screening use. In our study, we estimated the threshold costs for which CTC screening would be a cost-effective alternative to colonoscopy for colorectal cancer (CRC) screening in the general population. We used the MISCAN-colon microsimulation model to estimate the costs and life-years gained of screening persons aged 50-80 years for 4 screening strategies: (i) optical colonoscopy; and CTC with referral to optical colonoscopy of (ii) any suspected polyp; (iii) a suspected polyp >or=6 mm and (iv) a suspected polyp >or=10 mm. For each of the 4 strategies, screen intervals of 5, 10, 15 and 20 years were considered. Subsequently, for each CTC strategy and interval, the threshold costs of CTC were calculated. We performed a sensitivity analysis to assess the effect of uncertain model parameters on the threshold costs. With equal costs ($662), optical colonoscopy dominated CTC screening. For CTC to gain similar life-years as colonoscopy screening every 10 years, it should be offered every 5 years with referral of polyps >or=6 mm. For this strategy to be as cost-effective as colonoscopy screening, the costs must not exceed $285 or 43% of colonoscopy costs (range in sensitivity analysis: 39-47%). With 25% higher adherence than colonoscopy, CTC threshold costs could be 71% of colonoscopy costs. Our estimate of 43% is considerably lower than previous estimates in literature, because previous studies only compared CTC screening to 10-yearly colonoscopy, where we compared to different intervals of colonoscopy screening.

  9. Comparative Effectiveness of Fecal Immunochemical Test Outreach, Colonoscopy Outreach, and Usual Care for Boosting Colorectal Cancer Screening Among the Underserved

    PubMed Central

    Gupta, Samir; Halm, Ethan A.; Rockey, Don C.; Hammons, Marcia; Koch, Mark; Carter, Elizabeth; Valdez, Luisa; Tong, Liyue; Ahn, Chul; Kashner, Michael; Argenbright, Keith; Tiro, Jasmin; Geng, Zhuo; Pruitt, Sandi; Skinner, Celette Sugg

    2017-01-01

    IMPORTANCE Colorectal cancer (CRC) screening saves lives, but participation rates are low among underserved populations. Knowledge on effective approaches for screening the underserved, including best test type to offer, is limited. OBJECTIVE To determine (1) if organized mailed outreach boosts CRC screening compared with usual care and (2) if FIT is superior to colonoscopy outreach for CRC screening participation in an underserved population. DESIGN, SETTING, AND PARTICIPANTS We identified uninsured patients, not up to date with CRC screening, age 54 to 64 years, served by the John Peter Smith Health Network, Fort Worth and Tarrant County, Texas, a safety net health system. INTERVENTIONS Patients were assigned randomly to 1 of 3 groups. One group was assigned to fecal immunochemical test (FIT) outreach, consisting of mailed invitation to use and return an enclosed no-cost FIT (n = 1593). A second was assigned to colonoscopy outreach, consisting of mailed invitation to schedule a no-cost colonoscopy (n = 479). The third group was assigned to usual care, consisting of opportunistic primary care visit-based screening (n = 3898). In addition, FIT and colonoscopy outreach groups received telephone follow-up to promote test completion. MAIN OUTCOME MEASURES Screening participation in any CRC test within 1 year after randomization. RESULTS Mean patient age was 59 years; 64% of patients were women. The sample was 41% white, 24% black, 29% Hispanic, and 7% other race/ethnicity. Screening participation was significantly higher for both FIT (40.7%) and colonoscopy outreach (24.6%) than for usual care (12.1%) (P < .001 for both comparisons with usual care). Screening was significantly higher for FIT than for colonoscopy outreach (P < .001). In stratified analyses, screening was higher for FIT and colonoscopy outreach than for usual care, and higher for FIT than for colonoscopy outreach among whites, blacks, and Hispanics (P < .005 for all comparisons). Rates of CRC identification and advanced adenoma detection were 0.4% and 0.8% for FIT outreach, 0.4% and 1.3% for colonoscopy outreach, and 0.2% and 0.4% for usual care, respectively (P < .05 for colonoscopy vs usual care advanced adenoma comparison; P > .05 for all other comparisons). Eleven of 60 patients with abnormal FIT results did not complete colonoscopy. CONCLUSIONS AND REVELANCE Among underserved patients whose CRC screening was not up to date, mailed outreach invitations resulted in markedly higher CRC screening compared with usual care. Outreach was more effective with FIT than with colonoscopy invitation. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01191411 PMID:23921906

  10. "Appropriateness of colonoscopy according to EPAGE II in a low resource setting: a cross sectional study from Sri Lanka".

    PubMed

    Samarakoon, Yasara; Gunawardena, Nalika; Pathirana, Aloka; Hewage, Sumudu

    2018-05-29

    Due to finite resources, the clinical decision to subject a patient to colonoscopy needs to be based on the evidence, regardless of its availability, affordability and safety. This study assessed the appropriateness of colonoscopies conducted in selected study settings in Sri Lanka. In the absence of local guidelines, audit was based on European Panel on Appropriateness of Gastrointestinal Endoscopy II (EPAGE II) criteria. This cross-sectional study assessed consecutive patients who underwent colonoscopy between June to August 2015 at four main hospitals in Sri Lanka. Interviewer administered questionnaire and secondary data were collected by trained health staff. Indications were assessed according to EPAGE II criteria. Out of 325 patients, male female proportions were 57.2 and 42.8%. Mean (SD) age was 54.9 (12.1) years. Colonoscopies were appropriate in 61.2% (95% CI 55.8-66.3), uncertain in 28.6% (95% CI 23.9-33.7) and inappropriate in 10.2% (95% CI 7.3-13.9). Colonoscopy to evaluate abdominal pain has highest percentage of inappropriateness of 10.0%. However, 9.5% of these colonoscopies revealed Colo-Rectal Cancer (CRC), reflecting differences in the profile of local CRC patients. Colonoscopies with appropriate or uncertain indications are three times more likely to have a relevant finding than inappropriate indications (42.5% vs. 18.2%; OR 3.32, 95% CI 1.33-8.3; P = 0.008). Majority of colonoscopies are appropriate. However, it cannot be neglected that every one in ten patients undergo inappropriate colonoscopy. Proportion of inappropriateness was highest for the indication of chronic abdominal pain, of which, 9.5% of patients were diagnosed with CRC. This may reflect the different profile of local CRC patients in terms of symptom manifestation and other characteristics. In conclusion, the authors recommend formulation of national guidelines for colonoscopy indications based on current best evidence and local patient profile. Use of such prepared local guidelines will improve the efficient use of finite resources.

  11. Colorectal cancer screening in patients with spinal cord injury yields similar results to the general population with an effective bowel preparation: a retrospective chart audit.

    PubMed

    Teng, Brandon J; Song, Shawn H; Svircev, Jelena N; Dominitz, Jason A; Burns, Stephen P

    2018-03-01

    Retrospective chart audit. To compare adequacy of colonoscopy bowel preparation and diagnostic findings between persons with SCI receiving an extended inpatient bowel preparation and the general population. Veterans Affairs Puget Sound Healthcare System, Seattle, WA, USA. We reviewed an electronic database of all colonoscopies performed at a tertiary Veterans Affairs medical center between 7/12/13 and 15/10/15. Patients with SCI received a multi-day bowel preparation with magnesium citrate, and 8-10 liters of polyethylene glycol-3350 and electrolyte colonic lavage solution (PEG-ELS) over two and one half days. The control population received a standard bowel preparation consisting of magnesium citrate and 4 liters of PEG-ELS over 1 day. Two hundred and fifty-five patients were included in the study, including 85 patients with SCI. Average risk screening was a more common colonoscopy indication in patients with SCI vs. the control population (24 vs. 13% p = 0.03). There was no difference in adequacy of bowel preparation (87 vs. 85%, p = 0.73) or adenoma detection rate (55 vs. 51%, p = 0.59) when comparing patients with SCI with the control population. No difference in polyp histopathology was detected (p = 0.748). Our study demonstrated that an extended bowel preparation for patients with SCI produces similar bowel preparation results and diagnostic yield when compared to patients without SCI undergoing colonoscopy.

  12. Charity colonoscopy event to commemorate the 185th anniversary of Singapore General Hospital.

    PubMed

    Ng, Kheng Hong; Lim, Jit Fong; Ho, Kok Sun; Ooi, Boon Swee; Tang, Choong Leong; Eu, Kong Weng

    2008-03-01

    Colorectal cancer is now the cancer with the highest incidence in Singapore. However, the overall mortality rate is still about 50% because the majority of the patients present at a late stage of disease. A charity event of screening colonoscopy was offered to the public in conjunction with the 185th anniversary of Singapore General Hospital. The aim of this event was to raise awareness about early detection of colorectal cancer and the safety of colonoscopy. We conducted a one-off free screening event for colorectal cancer using colonoscopy. Four hundred and ninety individuals responded to a multimedia advertisement for the event. Of these, 220 individuals were selected for the screening based on National Guidelines for colorectal cancer screening and financial status. One hundred and fifty-two individuals turned up for the colonoscopy. The median age was 55 years (range, 22 to 82), with 84 males. Significant pathology was found in 33% of the individuals (n = 51). Colorectal polyps were detected in 34 individuals (22%). A total of 45 polyps were removed, with 20 hyperplastic polyps and 25 adenomas. Eight out of 25 adenomas were located proximal to the splenic flexure. Rectal cancer was diagnosed in 1 individual (0.6%). One individual had a large dysplastic rectosigmoid ulcer and refused further intervention. There were no significant complications from any of the colonoscopies. Colonoscopy is an invaluable screening modality as it has a high pick-up rate for colorectal polyp and cancer in an asymptomatic population. It is also proven to be safe in our study. It has the added advantage over flexible sigmoidoscopy of detecting a significant number of proximal lesions. Also, therapeutic polypectomy can be performed in the same setting.

  13. Cost-effectiveness of Competing Strategies for Management of Recurrent Clostridium difficile Infection: A Decision Analysis

    PubMed Central

    Konijeti, Gauree G.; Sauk, Jenny; Shrime, Mark G.; Gupta, Meera; Ananthakrishnan, Ashwin N.

    2014-01-01

    Background. Clostridium difficile infection (CDI) is an important cause of morbidity and healthcare costs, and is characterized by high rates of disease recurrence. The cost-effectiveness of newer treatments for recurrent CDI has not been examined, yet would be important to inform clinical practice. The aim of this study was to analyze the cost effectiveness of competing strategies for recurrent CDI. Methods. We constructed a decision-analytic model comparing 4 treatment strategies for first-line treatment of recurrent CDI in a population with a median age of 65 years: metronidazole, vancomycin, fidaxomicin, and fecal microbiota transplant (FMT). We modeled up to 2 additional recurrences following the initial recurrence. We assumed FMT delivery via colonoscopy as our base case, but conducted sensitivity analyses based on different modes of delivery. Willingness-to-pay threshold was set at $50 000 per quality-adjusted life-year. Results. At our base case estimates, initial treatment of recurrent CDI using FMT colonoscopy was the most cost-effective strategy, with an incremental cost-effectiveness ratio of $17 016 relative to oral vancomycin. Fidaxomicin and metronidazole were both dominated by FMT colonoscopy. On sensitivity analysis, FMT colonoscopy remained the most cost-effective strategy at cure rates >88.4% and CDI recurrence rates <14.9%. Fidaxomicin required a cost <$1359 to meet our cost-effectiveness threshold. In clinical settings where FMT is not available or applicable, the preferred strategy appears to be initial treatment with oral vancomycin. Conclusions. In this decision analysis examining treatment strategies for recurrent CDI, we demonstrate that FMT colonoscopy is the most cost-effective initial strategy for management of recurrent CDI. PMID:24692533

  14. Knowledge and attitudes of primary healthcare patients regarding population-based screening for colorectal cancer.

    PubMed

    Ramos, Maria; Llagostera, Maria; Esteva, Magdalena; Cabeza, Elena; Cantero, Xavier; Segarra, Manel; Martín-Rabadán, Maria; Artigues, Guillem; Torrent, Maties; Taltavull, Joana Maria; Vanrell, Joana Maria; Marzo, Mercè; Llobera, Joan

    2011-09-25

    ABSTRACT: BACKGROUND: The aim of this study was to assess the extent of knowledge of primary health care (PHC) patients about colorectal cancer (CRC), their attitudes toward population-based screening for this disease and gender differences in these respects. METHODS: A questionnaire-based survey of PHC patients in the Balearic Islands and some districts of the metropolitan area of Barcelona was conducted. Individuals between 50 and 69 years of age with no history of CRC were interviewed at their PHC centers. RESULTS: We analyzed the results of 625 questionnaires, 58% of which were completed by women. Most patients believed that cancer diagnosis before symptom onset improved the chance of survival. More women than men knew the main symptoms of CRC. A total of 88.8% of patients reported that they would perform the fecal occult blood test (FOBT) for CRC screening if so requested by PHC doctors or nurses. If the FOBT was positive and a colonoscopy was offered, 84.9% of participants indicated that they would undergo the procedure, and no significant difference by gender was apparent. Fear of having cancer was the main reason for performance of an FOBT, and also for not performing the FOBT, especially in women. Fear of pain was the main reason for not wishing to undergo colonoscopy. Factors associated with reluctance to perform the FOBT were: (i) the idea that that many forms of cancer can be prevented by exercise and, (ii) a reluctance to undergo colonoscopy if an FOBT was positive. Factors associated with reluctance to undergo colonoscopy were: (i) residence in Barcelona, (ii) ignorance of the fact that early diagnosis of CRC is associated with better prognosis, (iii) no previous history of colonoscopy, and (iv) no intention to perform the FOBT for CRC screening. CONCLUSION: We identified gaps in knowledge about CRC and prevention thereof in PHC patients from the Balearic Islands and the Barcelona region of Spain. If fears about CRC screening, and CRC per se, are addressed, and if it is emphasized that CRC is preventable, participation in CRC screening programs may improve.

  15. Budget Impact Analysis of Against Colorectal Cancer In Our Neighborhoods (ACCION): A Successful Community-Based Colorectal Cancer Screening Program for a Medically Underserved Minority Population.

    PubMed

    Kim, Bumyang; Lairson, David R; Chung, Tong Han; Kim, Junghyun; Shokar, Navkiran K

    2017-06-01

    Given the uncertain cost of delivering community-based cancer screening programs, we developed a Markov simulation model to project the budget impact of implementing a comprehensive colorectal cancer (CRC) prevention program compared with the status quo. The study modeled the impacts on the costs of clinical services, materials, and staff expenditures for recruitment, education, fecal immunochemical testing (FIT), colonoscopy, follow-up, navigation, and initial treatment. We used data from the Against Colorectal Cancer In Our Neighborhoods comprehensive CRC prevention program implemented in El Paso, Texas, since 2012. We projected the 3-year financial consequences of the presence and absence of the CRC prevention program for a hypothetical population cohort of 10,000 Hispanic medically underserved individuals. The intervention cohort experienced a 23.4% higher test completion rate for CRC prevention, 8 additional CRC diagnoses, and 84 adenomas. The incremental 3-year cost was $1.74 million compared with the status quo. The program cost per person was $261 compared with $86 for the status quo. The costs were sensitive to the proportion of high-risk participants and the frequency of colonoscopy screening and diagnostic procedures. The budget impact mainly derived from colonoscopy-related costs incurred for the high-risk group. The effectiveness of FIT to detect CRC was critically dependent on follow-up after positive FIT. Community cancer prevention programs need reliable estimates of the cost of CRC screening promotion and the added budget impact of screening with colonoscopy. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. The impact of receiving predictive genetic information about Lynch syndrome on individual colonoscopy and smoking behaviors

    PubMed Central

    Kim, Joanne Soo-Min; Coyte, Peter C.; Cotterchio, Michelle; Keogh, Louise A.; Flander, Louisa B.; Gaff, Clara; Laporte, Audrey

    2016-01-01

    Background This study investigated whether receiving the results of predictive genetic testing for Lynch syndrome—indicating the presence or absence of an inherited predisposition to various cancers, including colorectal cancer—was associated with change in individual colonoscopy and smoking behaviours, which could prevent colorectal cancer. Methods The study population included individuals with no previous diagnosis of colorectal cancer, whose families had already-identified deleterious mutations in the mismatch repair or EPCAM genes. Hypotheses were generated from a simple health economics model and tested against individual-level panel data from the Australasian Colorectal Cancer Family Registry. Results The empirical analysis revealed evidence consistent with some of the hypotheses, with a higher likelihood of undergoing colonoscopy in those who discovered their genetic predisposition to colorectal cancer and a lower likelihood of quitting smoking in those who discovered their lack thereof. Conclusion Predictive genetic information about Lynch syndrome was associated with change in individual colonoscopy and smoking behaviours but not necessarily in ways to improve population health. Impact The study findings suggest that the impact of personalized medicine on disease prevention is intricate, warranting further analyses to determine the net benefits and costs. PMID:27528600

  17. Colorectal Cancer Screening: Recommendations for Physicians and Patients from the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years.

  18. A Longitudinal Study of Adenoma Detection Rate in Gastroenterology Fellowship Training.

    PubMed

    Gianotti, Robert J; Oza, Sveta Shah; Tapper, Elliot B; Kothari, Darshan; Sheth, Sunil G

    2016-10-01

    Current guidelines suggest that a gastroenterology fellow in training needs to perform 140 colonoscopies to achieve competency. Data are limited regarding adenoma detection rate (ADR) in fellowship. To assess how fellow ADR correlates with number of colonoscopies performed. We performed a retrospective study examining consecutive colonoscopies performed by gastroenterology fellows. Fellow ADR before and after the 140 procedure benchmark was compared to colonoscopies performed by attending only with whom these fellows trained. A threshold for ideal procedure count was performed using ROC analysis. We analyzed 2021 average-risk colonoscopies performed by 10 gastroenterology fellows under the supervision of an attending physician. When fellows had performed <140 colonoscopies, the ADR was 27 % compared with an ADR of 36 % when fellows had performed >140 colonoscopies under attending supervision (p = 0.02). The ADR of fellows who had performed >140 colonoscopies under attending supervision was greater than that of attending-only colonoscopies (36 vs. 25 %, p < 0.0001). A threshold of >325 (male patients) and 539 (female patients) colonoscopies was determined to be ideal for achieving adequate ADR based on ROC analysis. Our data suggest that ADR increases after fellows perform >140 colonoscopies under attending supervision, and thereafter surpasses the ADR of attending-only colonoscopies. Some of the differences may be driven by detection of small adenomas. The findings of this study suggest that a higher threshold for number of colonoscopies performed under attending supervision may be needed to achieve adequate ADR during fellowship prior to independent practice.

  19. Examining the Impact of Latino Nativity, Migration, and Acculturation Factors on Colonoscopy Screening.

    PubMed

    Costas-Muñiz, Rosario; Jandorf, Lina; Philip, Errol; Cohen, Noah; Villagra, Cristina; Sriphanlop, Pathu; Schofield, Elizabeth; DuHamel, Katherine

    2016-10-01

    Latinos are a diverse population comprised of multiple countries of origin with varying cultural profiles. This study examines differences in colonoscopy completion across place of birth and migration-related factors in a sample of predominantly Dominican and Puerto Rican Latinos living in New York City after receiving a recommendation for colonoscopy screening and navigation services. The sample included 702 Latinos recruited for two cancer screening projects targeting Latinos eligible for colonoscopy who seek healthcare in New York City. Participants completed a survey that included sociodemographic, health-related questions, psychosocial assessments and cancer screening practices, in Spanish or English. Migration, acculturation, and language factors were found to predict colonoscopy completion. The results indicated that Latinos born in the Dominican Republic and Central America were more likely to complete a screening colonoscopy than their counterparts born in the US. Further, those who emigrated at an older age, who have resided in the US for less than 20 years, preferred Spanish and those with lower US acculturation levels were also more likely to complete a screening colonoscopy. The findings suggest that Latinos who are less acculturated to the US are more likely to complete a screening colonoscopy after receiving a physician recommendation for colonoscopy screening. The results provide important information that can inform clinical practice and public health interventions. Continued attention to cultural and migration influences are important areas for cancer screening intervention development.

  20. Colorectal tumors within an urban minority population in New York City.

    PubMed

    Kanna, Balavenkatesh; Schori, Melissa; Azeez, Sulaiman; Kumar, Suresh; Soni, Anita

    2007-06-01

    Data on gender- and age-specific predisposition to colorectal tumors and colorectal tumor location and stage among the urban minority population in Northeastern United States is limited. To study the age and gender distribution of colorectal tumor type, location, and stage of colorectal tumors among urban minorities. Retrospective analysis of a database of 4,043 consecutive colonoscopies performed over a 2-year period. PARTICIPANTS/MEASUREMENTS: Of study participants, 99% were Hispanic or African American and two-thirds were women. Age, gender, colonoscopy findings, and biopsy results were analyzed in all study subjects. Outcome measures are expressed as odds ratios (OR) with 95% confidence intervals (CI). Colonoscopies, 2,394 (63.4%), were performed for cancer screening. Women had higher visit volume adjusted odds to undergo colonoscopy (OR 1.35; CI 1.26-1.44, P < .001). Individuals, 960 (23.7%), had adenomas, and 82 (2.0%) had colorectal cancer. Although cancers were outnumbered by adenomas in the colon proximal to splenic flexure (OR 0.48; CI 0.29-0.80 P = .002), 51% of all abnormalities and 35.4% of cancers were found in this region. Of cancers, 75% belonged to AJCC stage 0 to 2. Men had higher odds for both adenomas and cancers (OR 2.38, CI 2.0-2.82, P < .001). More polyps occurred at a younger age. Of the cancers, 38% were noted among the 50- to 59-year-old subjects. However, the odds of colorectal cancers were higher at age greater than 70 years (OR 1.91; CI 1.09-3.27, P < .05), specifically among men (OR 2.27, 95% CI 1.07-4.65, P < .05). Our study of colonoscopies demonstrates lower odds of colonoscopy after adjusting for visit volume and greater predilection for colorectal cancer among urban minority men. Although older individuals were more likely to have colorectal cancer, a high percentage of colorectal tumors were noted at a younger age. These findings emphasize the vital need for preventive health education and improving early access to colorectal screening among urban minority men. A large proportion of colorectal tumors were found proximal to splenic flexure, which supports colonoscopy as the preferred method for colorectal cancer screening in the urban minority population in New York City.

  1. The role of colonoscopy in managing diverticular disease of the colon.

    PubMed

    Tursi, Antonio

    2015-03-01

    Diverticulosis of the colon is frequently found on routine colonoscopy, and the incidence of diverticular disease and its complications appears to be increasing. The role of colonoscopy in managing this disease is still controversial. Colonoscopy plays a key role in managing diverticular bleeding. Several techniques have been effectively used in this field, but band ligation seems to be the best in preventing rebleeding. Colonoscopy is also effective in posing a correct differential diagnosis with other forms of chronic colitis involving colon harbouring diverticula (in particular with Crohn's disease or Segmental Colitis Associated with Diverticulosis). The role of colonoscopy to confirm diagnosis of uncomplicated diverticulitis is still under debate, since the risk of advanced colonic neoplasia in patients admitted for acute uncomplicated diverticulitis is not increased as compared to the average-risk population. On the contrary, colonoscopy is mandatory if patients complain of persistent symptoms or after resolution of an episode of complicated diverticulitis. Finally, a recent endoscopic classification, called Diverticular Inflammation and Complications Assessment (DICA), has been developed and validated. This classification seems to be a promising tool for predicting the outcome of the colon harboring diverticula, but further, prospective studies have to confirm its predictive role on the outcome of the disease.

  2. Adenoma Detection Rates for Screening Colonoscopies in Smokers and Obese Adults: Data From the New Hampshire Colonoscopy Registry.

    PubMed

    Anderson, Joseph C; Weiss, Julia E; Robinson, Christina M; Butterly, Lynn F

    To examine screening adenoma detection rates (ADR) and serrated detection rates (SDR) among smokers and obese adults in the New Hampshire Colonoscopy Registry. ADR, a quality measure for screening colonoscopies, is associated with protection from interval colorectal cancer. Currently, only sex-specific ADR benchmarks are reported. However, obesity and smoking ≥20 pack-years are strong predictors for colorectal neoplasia, as highlighted by the 2009 American College of Gastroenterology CRC Screening Guidelines. Data comparing ADR in smokers and obese adults to those without these risks are limited. We calculated ADR, SDR, and 95% confidence intervals for screening colonoscopies in participants ≥50 years. Sex-specific and sex-age-specific rates were compared by smoking exposure (never vs. <20 vs. ≥20 pack-years) and body mass index (<30 vs. ≥30). A total of 21,539 screening colonoscopies were performed by 77 endoscopists at 20 facilities (April 2009 to September 2013). The difference in ADR between nonsmokers and smokers with ≥20 pack-years was 8.8% (P<0.0001) and between obesity groups 5.0% (P<0.0001). Significant sex-specific and sex-age-specific increases in ADR and SDR were found among smokers and obese participants. ADR and SDR for smokers and obese adults were significantly higher than their counterparts without those risks. Endoscopists should consider the prevalence of these risks within their screening population when comparing their rates to established benchmarks. Calculating sex-specific or sex-age-specific ADR and SDR based on smoking and obesity may provide optimal protection for populations with a particularly high prevalence of smokers and obese adults.

  3. [Acceptance and willingness-to-pay for colorectal colonoscopy screening among high-risk populations for colorectal cancer in urban China].

    PubMed

    Shi, Jufang; Huang, Huiyao; Guo, Lanwei; Ren, Jiansong; Ren, Ying; Lan, Li; Zhou, Qi; Mao, Ayan; Qi, Xiao; Liao, Xianzhen; Liu, Guoxiang; Bai, Yana; Cao, Rong; Liu, Yuqin; Wang, Yuanzheng; Gong, Jiyong; Li, Ni; Zhang, Kai; He, Jie; Dai, Min

    2015-05-01

    To survey the acceptance and willingness-to-pay for colorectal cancer colonoscopy screening among high risk populations in urban China. From 2012 to 2013, a Cancer Screening Program in Urban China (CanSPUC) was initiated in 9 provinces, the current survey was conducted among those participants who were evaluated as "high risk for colorectal cancer" by a risk-factor-evaluation-model (community-based) and then went through a colonoscopy screening procedure (hospital-based). All the data were obtained through a questionnaire-based interview (face-to-face or self-completed), mainly focusing on the acceptance and willingness-to-pay of the participants for colorectal colonoscopy screening. The current analysis included a total of 1 624 participants, with an median age of 55.0 years (P25 = 49.0, P75 = 61.0 years) and an annual income per capita of 17 thousand (range: 10-25 thousand) Chinese Yuan (CNY), 42.8% (695/1 624) of whom were males. Of all the participants, 87.0% (1 414/1 624) could totally or substantially accept the colonoscopy screening, particularly in those at higher education level (junior high school: OR = 0.34, 95% CI: 0.22-0.52; high school OR = 0.41, 95% CI: 0.26-0.66; college or over OR = 0.35, 95% CI: 0.20-0.59). Of all the participants, 13.0% (210/1 624) could not or hardly accept it, particularly in those with older age (60-69 years) (OR = 1.48, 95% CI: 1.06-2.07), not in marriage (OR = 2.15, 95% CI: 1.25-3.70) or with family member(s) to raise (OR = 1.60, 95% CI: 1.17-2.20). 1 388 (85.5%) of all the participants had willingness-to-pay for a long-term colonoscopy screening service, particularly in those working in public (OR = 0.61, 95% CI: 0.44-0.84) or enterprise sectors (OR = 0.60, 95% CI: 0.38-0.94), but 82.3% (1 141/1 386) of whom would only pay less than 100 CNY; 14.5% (236/1 624) of total had no willingness-to-pay, particularly in those living in areas with moderate (OR = 4.08, 95% CI: 2.75-6.33) or high GDP per capita (OR = 3.26, 95% CI: 2.11-4.92), or with an absence of willingness-to-pay for colonoscopy screening (OR = 3.98, 95% CI: 2.81-5.65). Although a larger community-based colorectal cancer screening program was warranted to examine the extrapolation of these findings, it suggested that the acceptance for colorectal cancer colonoscopy screening among the selected high-risk populations was considerable. The willing-to-pay was relatively high but the amount of payment was limited, the indicated subgroups with potentially less acceptance or willingness need to be more focused in the future to reach a higher participation rate. The data will also be informative in integrating the screening service into the local health insurance system.

  4. Polyethylene glycol powder solution versus senna for bowel preparation for colonoscopy in children.

    PubMed

    Terry, Natalie A; Chen-Lim, Mei Lin; Ely, Elizabeth; Jatla, Muralidhar; Ciavardone, Denise; Esch, Salina; Farace, Lisa; Jannelli, Frances; Puma, Anita; Carlow, Dean; Mamula, Petar

    2013-02-01

    Safety and effectiveness of large-volume polyethylene glycol-based solution (PEG-ES) have been documented, but the taste and volume can be barriers to successful colonoscopy preparation. Efficacy and safety of small-volume electrolyte-free (PEG-P) preparation (Miralax) for colonoscopy preparation have been rarely studied, although presently used at many pediatric centers. The primary objective of the present study was to determine whether PEG-P results in a more efficacious and safe colonoscopy preparation as compared with senna. The study design was prospective, randomized, and single-blinded. Patients ages 6 to 21 years were randomized to a 2-day clean-out regimen of PEG-P at a dose of 1.5 g/kg divided twice per day for 2 days versus senna 15 mL daily (ages 6-12) or 30 mL daily (ages 12-21) for 2 days. Both preparations required 1 day of clear liquids whereas senna preparation required an additional day of full liquid diet. A blinded endoscopist graded the quality of preparation with a standardized cleanliness tool (Aronchick scale). Serum chemistry panels were obtained. Patients or parents rated symptoms and ease of preparation. The anticipated number of subjects was 166; however, the interim analysis demonstrated inferiority of senna preparation. Thirty patients were evaluated in the present study. Of the patients in the PEG-P arm, 88% (14/16) received an excellent/good score compared with 29% (4/14), with the senna preparation (P = 0.0022). Both preparations were well-tolerated by patient-graded ease of preparation. Demographics and laboratory values did not differ significantly across the 2 groups. No serious adverse events were noted. PEG-P is an effective colonoscopy preparation whereas senna preparation was insufficient. Both were well-tolerated and appear safe in a pediatric population.

  5. Evaluation of a population-based approach to familial colorectal cancer.

    PubMed

    Parfrey, P S; Dicks, E; Parfrey, O; McNicholas, P J; Noseworthy, H; Woods, M O; Negriin, C; Green, J

    2017-05-01

    As Newfoundland has the highest rate of familial colorectal cancer (CRC) in the world, we started a population-based clinic to provide colonoscopic and Lynch syndrome (LS) screening recommendations to families of CRC patients based on family risk. Of 1091 incident patients 51% provided a family history. Seventy-two percent of families were at low or intermediate-low risk of CRC and colonoscopic screening recommendations were provided by letter. Twenty-eight percent were at high and intermediate-high risk and were referred to the genetic counsellor, but only 30% (N = 48) were interviewed by study end. Colonoscopy was recommended more frequently than every 5 years in 35% of families. Lower family risk was associated with older age of proband but the frequency of screening colonoscopy recommendations varied across all age groups, driven by variability in family history. Twenty-four percent had a high MMR predict score for a Lynch syndrome mutation, and 23% fulfilled the Provincial Program criteria for LS screening. A population-based approach in the provision of colonoscopic screening recommendations to families at risk of CRC was limited by the relatively low response rate. A family history first approach to the identification of LS families was inefficient. © 2016 The Authors. Clinical Genetics published by John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Colorectal cancer mortality reduction is associated with having at least 1 colonoscopy within the previous 10 years among a population-wide cohort of screening age.

    PubMed

    Stock, David; Paszat, Lawrence F; Rabeneck, Linda

    2016-07-01

    Colonoscopy has been demonstrated to be effective in colorectal cancer (CRC) mortality reduction, although current screening guidelines have yet to be evaluated. We assessed the protective benefit of colonoscopy within the previous 10 years and whether this effect is maintained with age. We used administrative data to compare risk of CRC death (CCD) across colonoscopy utilization among a population-wide cohort comprising individuals aged 60 to 80 years (N = 1,509,423). Baseline and time-dependent colonoscopy exposure models were assessed in the context of competing "other causes of death" (OCDs). Cumulative incidence of CCD and OCD across colonoscopy exposure, over follow-up, was estimated. Relative hazards were computed by age strata (60-69 years, 70-74 years, 75+ years) and proximal and distal cancer subsites. At least 1 colonoscopy during 10 years before baseline was estimated to provide a 51% reduced hazard of CCD (hazard ratio [HR] 0.49; 95% confidence interval [CI], 0.45-0.54) over the following 8 years. When colonoscopy was modeled as a time-dependent covariate, the risk of CCD was further diminished (multivariable-adjusted HR 0.36; 95% CI, 0.33-0.38). Stratified analyses suggested moderately attenuated CCD risk reduction among the oldest age group; however, consideration of OCDs suggest that this is related to competing risks. CCD risk reduction related to colonoscopy was lower for proximal cancers. Colonoscopy within the previous 10 years provides substantial protective benefit for average-risk individuals over 60 years. CCD risk reduction may be maintained well beyond 74 years, a common upper age limit recommended by screening guidelines. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. Colorectal Cancer Initial Diagnosis: Screening Colonoscopy, Diagnostic Colonoscopy, or Emergent Surgery, and Tumor Stage and Size at Initial Presentation.

    PubMed

    Moreno, Courtney C; Mittal, Pardeep K; Sullivan, Patrick S; Rutherford, Robin; Staley, Charles A; Cardona, Kenneth; Hawk, Natalyn N; Dixon, W Thomas; Kitajima, Hiroumi D; Kang, Jian; Small, William C; Oshinski, John; Votaw, John R

    2016-03-01

    Rates of colorectal cancer screening are improving but remain suboptimal. Limited information is available regarding how patients are diagnosed with colorectal cancer (for example, asymptomatic screened patients or diagnostic workup because of the presence of symptoms). The purpose of this investigation was to determine how patients were diagnosed with colorectal cancer (screening colonoscopy, diagnostic colonoscopy, or emergent surgery) and tumor stage and size at diagnosis. Adults evaluated between 2011 and 2014 with a diagnosis of colorectal cancer were identified. Clinical notes, endoscopy reports, surgical reports, radiology reports, and pathology reports were reviewed. Sex, race, ethnicity, age at the time of initial diagnosis, method of diagnosis, presenting symptom(s), and primary tumor size and stage at diagnosis were recorded. Colorectal cancer screening history was also recorded. The study population was 54% male (265 of 492) with a mean age of 58.9 years (range, 25-93 years). Initial tissue diagnosis was established at the time of screening colonoscopy in 10.7%, diagnostic colonoscopy in 79.2%, and during emergent surgery in 7.1%. Cancers diagnosed at the time of screening colonoscopy were more likely to be stage 1 than cancers diagnosed at the time of diagnostic colonoscopy or emergent surgery (38.5%, 7.2%, and 0%, respectively). Median tumor size was 3.0 cm for the screening colonoscopy group, 4.6 cm for the diagnostic colonoscopy group, and 5.0 cm for the emergent surgery group. At least 31% of patients diagnosed at the time of screening colonoscopy, 19% of patients diagnosed at the time of diagnostic colonoscopy, and 26% of patients diagnosed at the time of emergent surgery had never undergone a screening colonoscopy. Nearly 90% of colorectal cancer patients were diagnosed after development of symptoms and had more advanced disease than asymptomatic screening patients. Colorectal cancer outcomes will be improved by improving rates of colorectal cancer screening. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Colorectal cancer incidence in path_MLH1 carriers subjected to different follow-up protocols: a Prospective Lynch Syndrome Database report.

    PubMed

    Seppälä, Toni; Pylvänäinen, Kirsi; Evans, Dafydd Gareth; Järvinen, Heikki; Renkonen-Sinisalo, Laura; Bernstein, Inge; Holinski-Feder, Elke; Sala, Paola; Lindblom, Annika; Macrae, Finlay; Blanco, Ignacio; Sijmons, Rolf; Jeffries, Jacqueline; Vasen, Hans; Burn, John; Nakken, Sigve; Hovig, Eivind; Rødland, Einar Andreas; Tharmaratnam, Kukatharmini; de Vos Tot Nederveen Cappel, Wouter H; Hill, James; Wijnen, Juul; Jenkins, Mark; Genuardi, Maurizio; Green, Kate; Lalloo, Fiona; Sunde, Lone; Mints, Miriam; Bertario, Lucio; Pineda, Marta; Navarro, Matilde; Morak, Monika; Frayling, Ian M; Plazzer, John-Paul; Sampson, Julian R; Capella, Gabriel; Möslein, Gabriela; Mecklin, Jukka-Pekka; Møller, Pål

    2017-01-01

    We have previously reported a high incidence of colorectal cancer (CRC) in carriers of pathogenic MLH1 variants (path_MLH1 ) despite follow-up with colonoscopy including polypectomy. The cohort included Finnish carriers enrolled in 3-yearly colonoscopy ( n  = 505; 4625 observation years) and carriers from other countries enrolled in colonoscopy 2-yearly or more frequently ( n  = 439; 3299 observation years). We examined whether the longer interval between colonoscopies in Finland could explain the high incidence of CRC and whether disease expression correlated with differences in population CRC incidence. Cumulative CRC incidences in carriers of path_MLH1 at 70-years of age were 41% for males and 36% for females in the Finnish series and 58% and 55% in the non-Finnish series, respectively ( p  > 0.05). Mean time from last colonoscopy to CRC was 32.7 months in the Finnish compared to 31.0 months in the non-Finnish (p > 0.05) and was therefore unaffected by the recommended colonoscopy interval. Differences in population incidence of CRC could not explain the lower point estimates for CRC in the Finnish series. Ten-year overall survival after CRC was similar for the Finnish and non-Finnish series (88% and 91%, respectively; p > 0.05). The hypothesis that the high incidence of CRC in path_MLH1 carriers was caused by a higher incidence in the Finnish series was not valid. We discuss whether the results were influenced by methodological shortcomings in our study or whether the assumption that a shorter interval between colonoscopies leads to a lower CRC incidence may be wrong. This second possibility is intriguing, because it suggests the dogma that CRC in path_MLH1 carriers develops from polyps that can be detected at colonoscopy and removed to prevent CRC may be erroneous. In view of the excellent 10-year overall survival in the Finnish and non-Finnish series we remain strong advocates of current surveillance practices for those with LS pending studies that will inform new recommendations on the best surveillance interval.

  9. Correlation between adenoma detection rate in colonoscopy- and fecal immunochemical testing-based colorectal cancer screening programs.

    PubMed

    Cubiella, Joaquín; Castells, Antoni; Andreu, Montserrat; Bujanda, Luis; Carballo, Fernando; Jover, Rodrigo; Lanas, Ángel; Morillas, Juan Diego; Salas, Dolores; Quintero, Enrique

    2017-03-01

    The adenoma detection rate (ADR) is the main quality indicator of colonoscopy. The ADR recommended in fecal immunochemical testing (FIT)-based colorectal cancer screening programs is unknown. Using the COLONPREV (NCT00906997) study dataset, we performed a post-hoc analysis to determine if there was a correlation between the ADR in primary and work-up colonoscopy, and the equivalent figure to the minimal 20% ADR recommended. Colonoscopy was performed in 5722 individuals: 5059 as primary strategy and 663 after a positive FIT result (OC-Sensor™; cut-off level 15 µg/g of feces). We developed a predictive model based on a multivariable lineal regression analysis including confounding variables. The median ADR was 31% (range, 14%-51%) in the colonoscopy group and 55% (range, 21%-83%) in the FIT group. There was a positive correlation in the ADR between primary and work-up colonoscopy (Pearson's coefficient 0.716; p  < 0.001). ADR in the FIT group was independently related to ADR in the colonoscopy group: regression coefficient for colonoscopy ADR, 0.71 ( p  = 0.009); sex, 0.09 ( p  = 0.09); age, 0.3 ( p  = 0.5); and region 0.00 ( p  = 0.9). The equivalent figure to the 20% ADR was 45% (95% confidence interval, 35%-56%). ADR in primary and work-up colonoscopy of a FIT-positive result are positively and significantly correlated.

  10. Correlation between adenoma detection rate in colonoscopy- and fecal immunochemical testing-based colorectal cancer screening programs

    PubMed Central

    Castells, Antoni; Andreu, Montserrat; Bujanda, Luis; Carballo, Fernando; Jover, Rodrigo; Lanas, Ángel; Morillas, Juan Diego; Salas, Dolores; Quintero, Enrique

    2016-01-01

    Background The adenoma detection rate (ADR) is the main quality indicator of colonoscopy. The ADR recommended in fecal immunochemical testing (FIT)-based colorectal cancer screening programs is unknown. Methods Using the COLONPREV (NCT00906997) study dataset, we performed a post-hoc analysis to determine if there was a correlation between the ADR in primary and work-up colonoscopy, and the equivalent figure to the minimal 20% ADR recommended. Colonoscopy was performed in 5722 individuals: 5059 as primary strategy and 663 after a positive FIT result (OC-Sensor™; cut-off level 15 µg/g of feces). We developed a predictive model based on a multivariable lineal regression analysis including confounding variables. Results The median ADR was 31% (range, 14%–51%) in the colonoscopy group and 55% (range, 21%–83%) in the FIT group. There was a positive correlation in the ADR between primary and work-up colonoscopy (Pearson’s coefficient 0.716; p < 0.001). ADR in the FIT group was independently related to ADR in the colonoscopy group: regression coefficient for colonoscopy ADR, 0.71 (p = 0.009); sex, 0.09 (p = 0.09); age, 0.3 (p = 0.5); and region 0.00 (p = 0.9). The equivalent figure to the 20% ADR was 45% (95% confidence interval, 35%–56%). Conclusions ADR in primary and work-up colonoscopy of a FIT-positive result are positively and significantly correlated. PMID:28344793

  11. Rural Disparities in Treatment-Related Financial Hardship and Adherence to Surveillance Colonoscopy in Diverse Colorectal Cancer Survivors.

    PubMed

    McDougall, Jean A; Banegas, Matthew P; Wiggins, Charles L; Chiu, Vi K; Rajput, Ashwani; Kinney, Anita Y

    2018-03-28

    Cancer survivors increasingly report financial hardship as a consequence of the high cost of cancer care, yet the financial experience of rural cancer survivors remains largely unstudied. The purpose of this study was to investigate potential rural disparities in the likelihood of financial hardship and nonadherence to surveillance colonoscopy. Individuals diagnosed with localized or regional colorectal cancer (CRC) between 2004-2012 were ascertained by the population-based New Mexico Tumor Registry. Participants completed a mailed questionnaire or telephone survey about their CRC survivorship experience, including treatment-related financial hardship and receipt of surveillance colonoscopy. Multivariable logistic regression was used to estimate adjusted odds ratios (OR) and 95% confidence intervals (CI). Compared to urban CRC survivors (n=168), rural CRC survivors (n=109) were slightly older, more likely to be married (65% v. 59%) and have an annual income <$30,000 (37% v. 27%), less likely to be employed (35% v. 41%), have a college degree (28% v. 38%) or a high level of health literacy (39% v. 51%). Rural survivors were twice as likely as urban survivors to report treatment-related financial hardship (OR 1.86, 95% CI 1.06-3.28) and nonadherence to surveillance colonoscopy guidelines (OR 2.28, 95% CI 1.07-4.85). In addition, financial hardship was independently associated with nonadherence to surveillance colonoscopy (OR 2.17, 95% CI 1.01-4.85). Substantial rural disparities in the likelihood of financial hardship and nonadherence to surveillance colonoscopy exist. Treatment-related financial hardship among rural CRC survivors may negatively impact adherence to guideline recommended follow-up care. Copyright ©2018, American Association for Cancer Research.

  12. Impact of bowel preparation on surveillance colonoscopy interval.

    PubMed

    Singhal, Shashideep; Virk, Muhammad Asif; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury

    2014-07-01

    Atpresent there are no guidelines for colonoscopy surveillance interval in subjects with unsatisfactory bowel preparation. Study was designed to compare outcomes of repeat colonoscopy at different surveillance intervals in patients with unsatisfactory preparation on index exam. Ten thousand nine hundred and eight colonoscopies were done during the study period. Patients with index colonoscopy exam complete up to cecum but suboptimal bowel prep were included. Two hundred and ninety-seven patients met the inclusion criteria. The interval for repeat colonoscopy was <1 year in 38.5%, 1-2 years in 33.3%, 2-3 years in 16.7%, and 3-5 years in 11.5% subjects. Adenoma detection rate (ADR) was 24%, high-risk adenoma detection rate (HR-ADR) was 8.4%, and colorectal cancer detection rate was 1.7%. The HR-ADR based on surveillance intervals <1 year, 1-2 years, 2-3 years, and 3-5 years was 8%, 7.9%, 2%, and 19.4%, respectively. The HR-ADR was significantly higher at surveillance interval 3-5 years (p < 0.05). Colonoscopies repeated at interval >3 years showed a significant HR-ADR. The study indicates that a surveillance interval of 3 years can be reasonable for subjects having an index colonoscopy with suboptimal/fair/poor bowel prep and complete colon examination. Colonoscopy should be repeated earlier if symptoms develop.

  13. Obesity Increases Prevalence of Colonic Adenomas at Screening Colonoscopy: A Canadian Community-Based Study

    PubMed Central

    Chen, Grant I.; Devlin, Tim; Gibbs, Alison; Murray, Iain C.; Tran, Stanley; Weigensberg, Corey

    2017-01-01

    Background and Aims Obesity is a risk factor for colorectal neoplasia. We examined the influence of obesity and metabolic syndrome (MetS) on prevalence of neoplasia at screening colonoscopy. Methods We evaluated 2020 subjects undergoing first screening colonoscopy. Body mass index (BMI) was calculated at enrolment. Hyperlipidemia (HL), hypertension (HT), and diabetes mellitus (DM) were identified. Details of colonoscopy, polypectomy, and histology were recorded. Odds for adenomas (A) and advanced adenomas (ADV) in overweight (BMI 25.1–30) and obese (BMI > 30) subjects were assessed by multinomial regression, adjusted for covariates. Analyses included relationships between HL, HT, DM, age, tobacco usage, and neoplasia. Discriminatory power of HT, HL, DM, and BMI for neoplasia was assessed by binary logistic regression. Odds were calculated for neoplasia in each colonic segment related to BMI. Results A and ADV were commoner in overweight and obese males, obese females, older subjects, and smokers. HL, HT, and DM were associated with increased odds for neoplasia, significantly for A with hypertension. BMI alone predicted neoplasia as well as HT, HL, DM, or combinations thereof. All segments of the colon were affected. Multiple polyps were particularly prevalent in the obese. Conclusions Obesity and MetS are risk factors for colonic neoplasia in a Canadian population. PMID:28781966

  14. Colorectal Cancer Screening: Recommendations for Physicians and Patients From the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years. Copyright © 2017 AGA Institute, American College of Gastroenterology, and the American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Colonoscopy screening among US adults aged 40 or older with a family history of colorectal cancer.

    PubMed

    Tsai, Meng-Han; Xirasagar, Sudha; Li, Yi-Jhen; de Groen, Piet C

    2015-05-21

    Colonoscopy screening reduces colorectal cancer (CRC) incidence and mortality. CRC screening is recommended at age 50 for average-risk people. Screening of first-degree relatives of CRC patients is recommended to begin at age 40 or 10 years before the age at diagnosis of the youngest relative diagnosed with CRC. CRC incidence has increased recently among younger Americans while it has declined among older Americans. The objective of this study was to determine whether first-degree relatives of CRC patients are being screened according to recommended guidelines. We studied colonoscopy screening rates among the US population reporting a CRC family history using 2005 and 2010 National Health Interview Survey data. Of 26,064 study-eligible respondents, 2,470 reported a CRC family history; of those with a family history, 45.6% had a colonoscopy (25.2% in 2005 and 65.8% 2010). The colonoscopy rate among first-degree relatives aged 40 to 49 in 2010 (38.3%) was about half that of first-degree relatives aged 50 or older (69.7%). First-degree relatives were nearly twice as likely as nonfirst-degree relatives to have a colonoscopy (adjusted odds ratio [AOR], 1.7; 95% confidence interval, 1.5-1.9), but those aged 40 to 49 were less likely to have a colonoscopy than those in older age groups (AOR, 2.6 for age 50-64; AOR, 3.6 for age ≥65). Interactions with age, insurance, and race/ethnicity were not significant. Having health insurance tripled the likelihood of screening. Despite a 5-fold increase in colonoscopy screening rates since 2005, rates among first-degree relatives younger than the conventional screening age have lagged. Screening promotion targeted to this group may halt the recent rising trend of CRC among younger Americans.

  16. Feasibility of full-spectrum endoscopy: Korea’s first full-spectrum endoscopy colonoscopic trial

    PubMed Central

    Song, Jeong-Yeop; Cho, Youn Hee; Kim, Mi A; Kim, Jeong-Ae; Lee, Chun Tek; Lee, Moon Sung

    2016-01-01

    AIM: To evaluate the full-spectrum endoscopy (FUSE) colonoscopy system as the first report on the utility thereof in a Korean population. METHODS: We explored the efficacy of the FUSE colonoscopy in a retrospective, single-center feasibility study performed between February 1 and July 20, 2015. A total of 262 subjects (age range: 22-80) underwent the FUSE colonoscopy for colorectal cancer screening, polyp surveillance, or diagnostic evaluation. The cecal intubation success rate, the polyp detection rate (PDR), the adenoma detection rate (ADR), and the diverticulum detection rate (DDR), were calculated. Also, the success rates of therapeutic interventions were evaluated with biopsy confirmation. RESULTS: All patients completed the study and the success rates of cecal and terminal ileal intubation were 100% with the FUSE colonoscope; we found 313 polyps in 142 patients and 173 adenomas in 95. The overall PDR, ADR and DDR were 54.2%, 36.3%, and 25.2%, respectively, and were higher in males, and increased with age. The endoscopists and nurses involved considered that the full-spectrum colonoscope improved navigation and orientation within the colon. No colonoscopy was aborted because of colonoscope malfunction. CONCLUSION: The FUSE colonoscopy yielded a higher PDR, ADR, DDR than did traditional colonoscopy, without therapeutic failure or complications, showing feasible, effective, and safe in this first Korean trial. PMID:26937150

  17. Meat intake and risk of colorectal polyps: results from a large population-based screening study in Germany.

    PubMed

    Carr, Prudence R; Holleczek, Bernd; Stegmaier, Christa; Brenner, Hermann; Hoffmeister, Michael

    2017-06-01

    Background: Red and processed meats have been shown to be associated with colorectal adenomas in many, but not all, studies, and the association according to the type of colorectal adenoma or the location in the colorectum is unclear. Objectives: We investigated the association of meat intake in relation to colorectal polyps and further investigated the association according to histologic subtypes and subsites in a large population-based screening study in Germany. Design: In this cross-sectional study, 15,950 participants aged ≥55 y underwent a screening colonoscopy. We calculated prevalence ratios (PRs) and 95% CIs for associations between meat intake and the most-advanced findings from a colonoscopy with the use of log binomial regression. Results: Overall, 3340 participants (20.4%) had nonadvanced adenomas, 1643 participants (10.0%) had advanced adenomas, and 189 participants (1.2%) had colorectal cancer. We observed no statistically significant association between red or processed meat consumption and the prevalence of any adenomas or advanced adenomas [highest compared with lowest: red meat, PR: 1.07 (95% CI: 0.83, 1.37); processed meat, PR: 1.11 (95% CI: 0.91, 1.36)]. In site-specific analyses, although no dose-response relation was observed, processed meat was positively associated with the prevalence of advanced adenomas in the rectum only (multiple times per day compared with <1 time/wk, PR: 1.87; 95% CI: 1.19, 2.95). Poultry intake was not associated with any outcome. Conclusions: On the basis of this large colonoscopy-based study, there are no significant associations between red or processed meat intake and the prevalence of any adenomas or advanced adenomas. However, processed meat may be positively associated with the prevalence of advanced adenomas in the rectum, but prospective cohort studies are needed to further clarify this association. There is no association between poultry consumption and the prevalence of colorectal polyps in this study. © 2017 American Society for Nutrition.

  18. Cost-Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.

    PubMed

    Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris

    2017-12-27

    Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared to the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon microsimulation model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess whether optimal screening strategies would change. Colonoscopy every 5 years, starting at age 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in population is not clear. Using a Microsimulation Screening Analysis-Colon microsimulation model, we found screening of patients with cystic fibrosis for CRC to be cost-effective. Due to the higher risk in these patients for CRC, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT screening) may be limited by restricted evidence available for patients with cystic fibrosis. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  19. Cost Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.

    PubMed

    Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris

    2018-02-01

    Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared with the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess if optimal screening strategies would change. Colonoscopy every 5 years, starting at an age of 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in this population is not clear. Using a Microsimulation Screening Analysis-Colon model, we found screening of patients with cystic fibrosis for CRC to be cost effective. Because of the higher risk of CRC in these patients, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT screening) may be limited by restricted evidence available for patients with cystic fibrosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  20. An investigation of diverticular disease among black patients undergoing colonoscopy at Dr George Mukhari Academic Hospital, Pretoria, South Africa.

    PubMed

    Vally, M; Koto, M Z; Govender, M

    2017-01-30

    Diverticular disease was previously thought to be non-existent in the black African population. Studies over the past four decades, however, have shown a steady increase in the prevalence of the disease. To report on the profile and current prevalence of diverticular disease in the black South African (SA) population at Dr George Mukhari Academic Hospital, Pretoria, SA. A retrospective descriptive study was performed in black SA patients who were diagnosed with diverticular disease by colonoscopy between 1 January and 31 December 2015. Of 348 patients who had undergone colonoscopies and who were eligible for inclusion in this study, 47 were diagnosed with diverticular disease - a prevalence of 13.50% (95% confidence interval 10.30 - 17.50). The greatest number of patients diagnosed were in their 7th and 8th decades, with an age range of 46 - 86 (mean 67) years. There was a female predominance of 57.45%. Lower gastrointestinal bleeding was the most common (65.96%) indication for colonoscopy. The left colon was most commonly involved (72.34%), followed by the right colon (55.31%). A substantial number of patients had pancolonic involvement (27.65%). This retrospective study suggests that there has been a considerable increase in the prevalence of diverticular disease among black South Africans, possibly owing to changes in dietary habits and socioeconomic status.

  1. Projected national impact of colorectal cancer screening on clinical and economic outcomes and health services demand.

    PubMed

    Ladabaum, Uri; Song, Kenneth

    2005-10-01

    Colorectal cancer (CRC) screening is effective and cost-effective, but the potential national impact of widespread screening is uncertain. It is controversial whether screening colonoscopy can be offered widely and how emerging tests may impact health services demand. Our aim was to produce integrated, comprehensive estimates of the impact of widespread screening on national clinical and economic outcomes and health services demand. We used a Markov model and census data to estimate the national consequences of screening 75% of the US population with conventional and emerging strategies. Screening decreased CRC incidence by 17%-54% to as few as 66,000 cases per year and CRC mortality by 28%-60% to as few as 23,000 deaths per year. With no screening, total annual national CRC-related expenditures were 8.4 US billion dollars. With screening, expenditures for CRC care decreased by 1.5-4.4 US billion dollars but total expenditures increased to 9.2-15.4 US billion dollars. Screening colonoscopy every 10 years required 8.1 million colonoscopies per year including surveillance, with other strategies requiring 17%-58% as many colonoscopies. With improved screening uptake, total colonoscopy demand increased in general, even assuming substantial use of virtual colonoscopy. Despite savings in CRC care, widespread screening is unlikely to be cost saving and may increase national expenditures by 0.8-2.8 US billion dollars per year with conventional tests. The current national endoscopic capacity, as recently estimated, may be adequate to support widespread use of screening colonoscopy in the steady state. The impact of emerging tests on colonoscopy demand will depend on the extent to which they replace screening colonoscopy or increase screening uptake in the population.

  2. Organized colorectal cancer screening in Serbia - the first round within 2013-2014.

    PubMed

    Banković Lazarević, Dušica; Krivokapić, Zoran; Barišić, Goran; Jovanović, Verica; Ilić, Dragan; Veljković, Marko

    2016-04-01

    The National Organized Colorectal Cancer Screening Program was conducted in the Republic of Serbia during 2013-2014 covering the population of both genders, aged 50 to 74 years, in 28 municipalities out of 180, with the target population of 651,445 people. This organized colorectal cancer screening aims to reduce mortality from colorectal cancer in the target population. The aim of this study was to show the results of organized screening for colorectal cancer during the first biannual round in Serbia. General practitioners from the primary health centers, invited target population by letters and by phone to perform immunochemical fecal occult blood test. Persons with a positive test results were referred to the colonoscopy. The database of health insurance and other citizens of the target population was used for invitation for screening in primary health centers. Descriptive statistical analysis of the results in organized colorectal cancer screening in the first round was performed for the key screening indicators. In the first round, a total of 99,592 persons were invited. The participation rate was 62.5%. Colonoscopy was performed in 1,554 persons. Adenomas were found in 586 persons (0.9% of all the tested), e.g. 37.7 % of all colonoscopied. In 129 persons colorectal cancer was diagnosed (0.2% of all the tested), e.g. 8.3% of all the colonoscopied. In the left half of the colon (rectum, sigmoid and descending colon) there were 70.4% diagnosed polyps and 77.3% carcinomas, while 29.6% of polyps and 22.7% carcinomas were found in the proximal parts of the colon. In the first round of the organized colorectal cancer screening in Serbia the participation rate of the targeted population was high and gave encouraging result. It was expected that in the forthcoming rounds even higher coverage of the target population would be accomplished. A positive predictive value of the completed colonoscopies showed that further work on observing the stages of diagnosed adenomas and carcinomas would reach the goals of the expected improvement in early detection of colorectal cancer in Serbia.

  3. Challenges to replicating evidence-based research in real-world settings: training African-American peers as patient navigators for colon cancer screening.

    PubMed

    Sly, Jamilia R; Jandorf, Lina; Dhulkifl, Rayhana; Hall, Diana; Edwards, Tiffany; Goodman, Adam J; Maysonet, Elithea; Azeez, Sulaiman

    2012-12-01

    Many cancer-prevention interventions have demonstrated effectiveness in diverse populations, but these evidenced-based findings slowly disseminate into practice. The current study describes the process of disseminating and replicating research (i.e., peer patient navigation for colonoscopy screening) in real-world settings. Two large metropolitan hospitals collaborated to replicate a peer patient navigation model within their existing navigation systems. Six African-American peer volunteers were recruited and trained to navigate patients through colonoscopy scheduling and completion. Major challenges included: (1) operating within multiple institutional settings; (2) operating within nonacademic/research infrastructures; (3) integrating into an established navigation system; (4) obtaining support of hospital staff without overburdening; and (5) competing priorities and time commitments. Bridging the gap between evidence-based research and practice is critical to eliminating many cancer health disparities; therefore, it is crucial that researchers and practitioners continue to work to achieve both diffusion and fusion of evidence-based findings. Recommendations for addressing these challenges are discussed.

  4. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    PubMed

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  5. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy

    PubMed Central

    Wong, Martin CS; Ching, Jessica YL; Chan, Victor CW; Sung, Joseph JY

    2015-01-01

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC. PMID:26338314

  6. Comparative effectiveness and cost-effectiveness of screening colonoscopy vs. sigmoidoscopy and alternative strategies.

    PubMed

    Sharaf, Ravi N; Ladabaum, Uri

    2013-01-01

    Fecal occult blood testing (FOBT) and sigmoidoscopy are proven to decrease colorectal cancer (CRC) incidence and mortality. Sigmoidoscopy's benefit is limited to the distal colon. Observational data are conflicting regarding the degree to which colonoscopy affords protection against proximal CRC. Our aim was to explore the comparative effectiveness and cost-effectiveness of colonoscopy vs. sigmoidoscopy and alternative CRC screening strategies in light of the latest published data. We performed a contemporary cost-utility analysis using a Markov model validated against data from randomized controlled trials of FOBT and sigmoidoscopy. Persons at average CRC risk within the general US population were modeled. Screening strategies included those recommended by the United States (US) Preventive Services Task Force, including colonoscopy every 10 years (COLO), flexible sigmoidoscopy every 5 years (FS), annual fecal occult blood testing, annual fecal immunochemical testing (FIT), and the combination FS/FIT. The main outcome measures were quality-adjusted life-years (QALYs) and costs. In the base case, FIT dominated other strategies. The advantage of FIT over FS and COLO was contingent on rates of uptake and adherence that are well above current US rates. Compared with FIT, FS and COLO both cost <$50,000/QALY gained when FIT per-cycle adherence was <50%. COLO cost $56,800/QALY gained vs. FS in the base case. COLO cost <$100,000/QALY gained vs. FS when COLO yielded a relative risk of proximal CRC of <0.5 vs. no screening. In probabilistic analyses, COLO was cost-effective vs. FS at a willingness-to-pay threshold of $100,000/QALY gained in 84% of iterations. Screening colonoscopy may be cost-effective compared with FIT and sigmoidoscopy, depending on the relative rates of screening uptake and adherence and the protective benefit of colonoscopy in the proximal colon. Colonoscopy's cost-effectiveness compared with sigmoidoscopy is contingent on the ability to deliver ~50% protection against CRC in the proximal colon.

  7. Colonoscopy Screening in the US Astronaut Corps

    NASA Technical Reports Server (NTRS)

    Masterova, K.; Van Baalen, M.; Wear, M. L.; Murray, J.; Schaefer, C.

    2016-01-01

    Historically, colonoscopy screenings for astronauts have been conducted to ensure that astronauts are in good health for space missions. This data has been identified as being useful for determining appropriate occupational surveillance targets and requirements. Colonoscopies in the astronaut corps can be used for: (a) Assessing overall colon health, (b) A point of reference for future tests in current and former astronauts, (c) Following-up and tracking rates of colorectal cancer and polyps; and (d) Comparison to military and other terrestrial populations. In 2003, medical screening requirements for the active astronaut corps changed to require less frequent colonoscopies. Polyp removal during a colonoscopy is an intervention that prevents the polyp from potentially developing into cancer and decreases the individual's risk for colon cancer.

  8. Increasing Colonoscopy Screening in Disparate Populations: Results From an Evaluation of Patient Navigation in the New Hampshire Colorectal Cancer Screening Program

    PubMed Central

    Rice, Ketra; Gressard, Lindsay; DeGroff, Amy; Gersten, Joanne; Robie, Janene; Leadbetter, Steven; Glover-Kudon, Rebecca; Butterly, Lynn

    2018-01-01

    BACKGROUND To investigate uniformly successful results from a statewide program of patient navigation (PN) for colonoscopy, this comparison study evaluated the effectiveness of the PN intervention by comparing outcomes for navigated versus non-navigated patients in one of the community health clinics included in the statewide program. Outcomes measured included screening completion, adequacy of bowel preparation, missed appointments and cancellations, communication of test results, and consistency of follow-up recommendations with clinical guidelines. METHODS The authors compared a subset of 131 patients who were navigated to a screening or surveillance colonoscopy with a similar subset of 75 non-navigated patients at one endoscopy clinic. The prevalence and prevalence odds ratios were computed to measure the association between PN and each study outcome measure. RESULTS Patients in the PN intervention group were 11.2 times more likely to complete colonoscopy than control patients (96.2% vs 69.3%; P<.001), and were 5.9 times more likely to have adequate bowel preparation (P =.010). In addition, intervention patients had no missed appointments compared with 15.6% of control patients, and were 24.8 times more likely to not have a cancellation <24 hours before their appointment (P<.001). All navigated patients and their primary care providers received test results, and all follow-up recommendations were consistent with clinical guidelines compared with 82.4% of patients in the control group (P<.001). CONCLUSIONS PN appears to be effective for improving colonoscopy screening completion and quality in the disparate populations most in need of intervention. To the best of our knowledge, the results of the current study demonstrate some of the strongest evidence for the effectiveness of PN to date, and highlight its value for public health. PMID:28464213

  9. Colonoscopy Screening in the US Astronaut Corps

    NASA Technical Reports Server (NTRS)

    Masterova, K.; Van Baalen, M.; Wear, M. L.; Murray, J.; Schaefer, C.

    2016-01-01

    BACKGROUND: Historically, colonoscopy screenings for astronauts have been conducted to ensure that astronauts are in good health for space missions. Recently this historical data has been identified as being useful for developing an occupational surveillance requirement. It can be used to assess overall colon health and to have a point of reference for future tests in current and former astronauts, as well as to follow-up and track rates of colorectal cancer and polyps. These rates can be compared to military and other terrestrial populations. In 2003, the active astronaut colonoscopy requirements changed to require less frequent colonoscopies. Since polyp removal during a colonoscopy is an intervention that prevents the polyp from potentially developing into cancer, the procedure decreases the individual's risk for colon cancer. The objective of this study is to evaluate the possible effect of increased follow-up times between colonoscopies on the number and severity of polyps identified during the procedures among both current and former NASA astronauts. Initial results and forward work regarding astronaut colonoscopy screenings will be presented. METHODS: A retrospective study of all colonoscopy procedures performed on NASA astronauts between 1962 and 2015 (both during active career and retirement) was conducted by review of the JSC Clinic Electronic Medical Record and Lifetime Surveillance of Astronaut Health (LSAH) database for colonoscopy screening procedures and pathology reports. The timeframe of interest was from the time of selection into the Astronaut Corps through May 2015 or death. For each colonoscopy report, the following data were captured: date of procedure, age at time of procedure, reason for procedure, quality of bowel prep, completion of procedure and/or reason for termination of procedure, findings of procedure, subsequent treatment (if any), recommended follow-up interval, actual follow up interval, family history of polyps or colon cancer, and other significant items or discrepancies. The population consisted of 338 astronauts: 52 females, 286 males. Of these, 56 were deceased, and 11 astronauts had no record of any colonoscopies. Because of a screening requirement change in 2003, analyses were conducted to determine if there were differences between the two time periods. One-sided Wilcoxon rank sum tests were used to identify statistically significant differences between the two time periods. RESULTS: There was a combined total of 1,964 colonoscopy screenings identified. The average follow-up intervals between colonoscopies were indeed longer after the screening requirement change than before the change. The mean follow-up interval pre -2003 was 3.59 years, while post-2003 it increased to 4.35 years. The statistical significance of this difference was confirmed using a one sided Wilcoxon rank sum test which yielded p<.001. Colonoscopies performed after the requirement change tended to have a higher incidence and greater severity of polyps. From pre-2003 to post-2003 the percentage of colonoscopy procedures yielding no polyps decreased from 83.77% to 74.70%. Not only did post-2003 procedures yield more polyp findings, but the polyps recorded were more often of severe pathology. Before 2003 3.62% of colonoscopy findings were polyps of the hyperplastic type (the least severe polyp type) and only 3.35% were of greater severity. Post-2003, 4.21% of findings were hyperplastic polyps while 11.44% were of greater severity. Upon the investigation of other possible contributing factors to these results, we also found that mean age post-2003 was 54.55 years which was significantly higher than during the pre-2003 timeframe (47.32 years). This was observed with a one-sided Wilcoxon rank sum test, resulting in a p<0.001. The increased average age of astronauts could also be a contributing factor to the greater number of polyps found since the risk of developing polyps increases with age. Further work is needed to better understand the increased incidence and greater severity of polyps found in astronaut colonoscopy outcomes.

  10. Refining the Patient Navigation Role in a Colorectal Cancer Screening Program: Results From an Intervention Study.

    PubMed

    Rohan, Elizabeth A; Slotman, Beth; DeGroff, Amy; Morrissey, Kerry Grace; Murillo, Jennifer; Schroy, Paul

    2016-11-01

    Oncology patient navigators help individuals overcome barriers to increase access to cancer screening, diagnosis, and timely treatment. This study, part of a randomized intervention trial investigating the efficacy of patient navigation in increasing colonoscopy completion, examined navigators' activities to ameliorate barriers to colonoscopy screening in a medically disadvantaged population. This study was conducted from 2012 through 2014 at Boston Medical Center. We analyzed navigator service delivery and survey data collected on 420 participants who were navigated for colonoscopy screening after randomization to this intervention. Key variables under investigation included barriers to colonoscopy, activities navigators undertook to reduce barriers, time navigators spent on each activity and per contact, and patient satisfaction with navigation services. Descriptive analysis assessed how navigators spent their time and examined what aspects of patient navigation were most valued by patients. Navigators spent the most time assessing patient barriers/needs; facilitating appointment scheduling; reminding patients of appointments; educating patients about colorectal cancer, the importance of screening, and the colonoscopy preparation and procedures; and arranging transportation. Navigators spent an average of 44 minutes per patient. Patients valued the navigators, especially for providing emotional/peer support and explaining screening procedures and bowel preparation clearly. Our findings help clarify the role of the navigator in colonoscopy screening within a medically disadvantaged community. These findings may help further refine the navigator role in cancer screening and treatment programs as facilities strive to effectively and efficiently integrate navigation into their services. Copyright © 2016 by the National Comprehensive Cancer Network.

  11. Refining the Patient Navigation Role in a Colorectal Cancer Screening Program: Results From an Intervention Study

    PubMed Central

    Rohan, Elizabeth A.; Slotman, Beth; DeGroff, Amy; Morrissey, Kerry Grace; Murillo, Jennifer; Schroy, Paul

    2017-01-01

    Background Oncology patient navigators help individuals overcome barriers to increase access to cancer screening, diagnosis, and timely treatment. This study, part of a randomized intervention trial investigating the efficacy of patient navigation in increasing colonoscopy completion, examined navigators' activities to ameliorate barriers to colonoscopy screening in a medically disadvantaged population. Methods This study was conducted from 2012 through 2014 at Boston Medical Center. We analyzed navigator service delivery and survey data collected on 420 participants who were navigated for colonoscopy screening after randomization to this intervention. Key variables under investigation included barriers to colonoscopy, activities navigators undertook to reduce barriers, time navigators spent on each activity and per contact, and patient satisfaction with navigation services. Descriptive analysis assessed how navigators spent their time and examined what aspects of patient navigation were most valued by patients. Results Navigators spent the most time assessing patient barriers/needs; facilitating appointment scheduling; reminding patients of appointments; educating patients about colorectal cancer, the importance of screening, and the colonoscopy preparation and procedures; and arranging transportation. Navigators spent an average of 44 minutes per patient. Patients valued the navigators, especially for providing emotional/peer support and explaining screening procedures and bowel preparation clearly. Conclusions Our findings help clarify the role of the navigator in colonoscopy screening within a medically disadvantaged community. These findings may help further refine the navigator role in cancer screening and treatment programs as facilities strive to effectively and efficiently integrate navigation into their services. PMID:27799508

  12. Factors Associated with Adenoma Detection Rate and Diagnosis of Polyps and Colorectal Cancer during Colonoscopy in France: Results of a Prospective, Nationwide Survey

    PubMed Central

    Barret, Maximilien; Boustiere, Christian; Canard, Jean-Marc; Arpurt, Jean-Pierre; Bernardini, David; Bulois, Philippe; Chaussade, Stanislas; Heresbach, Denis; Joly, Isabelle; Lapuelle, Jean; Laugier, René; Lesur, Gilles; Pienkowski, Patrice; Ponchon, Thierry; Pujol, Bertrand; Richard-Molard, Bruno; Robaszkiewicz, Michel; Systchenko, Rémi; Abbas, Fatima; Schott-Pethelaz, Anne-Marie; Cellier, Christophe

    2013-01-01

    Introduction Colonoscopy can prevent deaths due to colorectal cancer (CRC) through early diagnosis or resection of colonic adenomas. We conducted a prospective, nationwide study on colonoscopy practice in France. Methods An online questionnaire was administered to 2,600 French gastroenterologists. Data from all consecutive colonoscopies performed during one week were collected. A statistical extrapolation of the results to a whole year was performed, and factors potentially associated with the adenoma detection rate (ADR) or the diagnosis of polyps or cancer were assessed. Results A total of 342 gastroenterologists, representative of the overall population of French gastroenterologists, provided data on 3,266 colonoscopies, corresponding to 1,200,529 (95% CI: 1,125,936-1,275,122) procedures for the year 2011. The indication for colonoscopy was CRC screening and digestive symptoms in 49.6% and 38.9% of cases, respectively. Polypectomy was performed in 35.5% of cases. The ADR and prevalence of CRC were 17.7% and 2.9%, respectively. The main factors associated with a high ADR were male gender (p=0.0001), age over 50 (p=0.0001), personal or family history of CRC or colorectal polyps (p<0.0001 and p<0.0001, respectively), and positive fecal occult blood test (p=0.0005). The prevalence of CRC was three times higher in patients with their first colonoscopy (4.2% vs. 1.4%; p<0.0001). Conclusions For the first time in France, we report nationwide prospective data on colonoscopy practice, including histological results. We found an average ADR of 17.7%, and observed reduced CRC incidence in patients with previous colonoscopy. PMID:23874822

  13. Factors associated with adenoma detection rate and diagnosis of polyps and colorectal cancer during colonoscopy in France: results of a prospective, nationwide survey.

    PubMed

    Barret, Maximilien; Boustiere, Christian; Canard, Jean-Marc; Arpurt, Jean-Pierre; Bernardini, David; Bulois, Philippe; Chaussade, Stanislas; Heresbach, Denis; Joly, Isabelle; Lapuelle, Jean; Laugier, René; Lesur, Gilles; Pienkowski, Patrice; Ponchon, Thierry; Pujol, Bertrand; Richard-Molard, Bruno; Robaszkiewicz, Michel; Systchenko, Rémi; Abbas, Fatima; Schott-Pethelaz, Anne-Marie; Cellier, Christophe

    2013-01-01

    Colonoscopy can prevent deaths due to colorectal cancer (CRC) through early diagnosis or resection of colonic adenomas. We conducted a prospective, nationwide study on colonoscopy practice in France. An online questionnaire was administered to 2,600 French gastroenterologists. Data from all consecutive colonoscopies performed during one week were collected. A statistical extrapolation of the results to a whole year was performed, and factors potentially associated with the adenoma detection rate (ADR) or the diagnosis of polyps or cancer were assessed. A total of 342 gastroenterologists, representative of the overall population of French gastroenterologists, provided data on 3,266 colonoscopies, corresponding to 1,200,529 (95% CI: 1,125,936-1,275,122) procedures for the year 2011. The indication for colonoscopy was CRC screening and digestive symptoms in 49.6% and 38.9% of cases, respectively. Polypectomy was performed in 35.5% of cases. The ADR and prevalence of CRC were 17.7% and 2.9%, respectively. The main factors associated with a high ADR were male gender (p=0.0001), age over 50 (p=0.0001), personal or family history of CRC or colorectal polyps (p<0.0001 and p<0.0001, respectively), and positive fecal occult blood test (p=0.0005). The prevalence of CRC was three times higher in patients with their first colonoscopy (4.2% vs. 1.4%; p<0.0001). For the first time in France, we report nationwide prospective data on colonoscopy practice, including histological results. We found an average ADR of 17.7%, and observed reduced CRC incidence in patients with previous colonoscopy.

  14. Performance of a quantitative fecal immunochemical test in a colorectal cancer screening pilot program: a prospective cohort study.

    PubMed

    Telford, Jennifer; Gentile, Laura; Gondara, Lovedeep; McGahan, Colleen; Coldman, Andrew

    2016-01-01

    British Columbia undertook a colorectal cancer screening pilot program in 3 communities. Our objective was to assess the performance of 2-specimen fecal immunochemical testing in the detection of colorectal neoplasms in this population-based screening program. A prospective cohort of asymptomatic, average-risk people aged 50 to 74 years completed 2 quantitative fecal immunochemical tests every 2 years, with follow-up colonoscopy if the result of either test was positive. Participant demographics, fecal immunochemical test results, colonoscopy quality indicators and pathology results were recorded. Non-screen-detected colorectal cancer that developed in program participants was identified through review of data from the BC Cancer Registry. A total of 16 234 people completed a first round of fecal immunochemical testing, with a positivity rate of 8.6%; 5378 (86.0% of eligible participants) completed a second round before the end of the pilot program, with a positivity rate of 6.7%. Of the 1756 who had a positive test result, 1555 (88.6%) underwent colonoscopy. The detection rate of colorectal cancer was 3.5 per 1000 participants. The positive predictive value of the fecal immunochemical test was 4.9% (95% confidence interval [CI] 3.8%-6.0%) for colorectal cancer, 35.0% (95% CI 32.5%-37.2%) for high-risk polyps and 62.0% (95% CI 59.6%-64.4%) for all neoplasms. The number needed to screen was 283 to detect 1 cancer, 40 to detect 1 high-risk polyp and 22 to detect any neoplasm. Screening every 2 years with a 2-specimen fecal immunochemical test surpassed the current benchmark for colorectal cancer detection in population-based screening. This study has implications for other jurisdictions planning colorectal cancer screening programs.

  15. Evaluation of colonoscopy technical skill levels by use of an objective kinematic-based system.

    PubMed

    Obstein, Keith L; Patil, Vaibhav D; Jayender, Jagadeesan; San José Estépar, Raúl; Spofford, Inbar S; Lengyel, Balazs I; Vosburgh, Kirby G; Thompson, Christopher C

    2011-02-01

    Colonoscopy requires training and experience to ensure accuracy and safety. Currently, no objective, validated process exists to determine when an endoscopist has attained technical competence. Kinematics data describing movements of laparoscopic instruments have been used in surgical skill assessment to define expert surgical technique. We have developed a novel system to record kinematics data during colonoscopy and quantitatively assess colonoscopist performance. To use kinematic analysis of colonoscopy to quantitatively assess endoscopic technical performance. Prospective cohort study. Tertiary-care academic medical center. This study involved physicians who perform colonoscopy. Application of a kinematics data collection system to colonoscopy evaluation. Kinematics data, validated task load assessment instrument, and technical difficulty visual analog scale. All 13 participants completed the colonoscopy to the terminal ileum on the standard colon model. Attending physicians reached the terminal ileum quicker than fellows (median time, 150.19 seconds vs 299.86 seconds; p<.01) with reduced path lengths for all 4 sensors, decreased flex (1.75 m vs 3.14 m; P=.03), smaller tip angulation, reduced absolute roll, and lower curvature of the endoscope. With performance of attending physicians serving as the expert reference standard, the mean kinematic score increased by 19.89 for each decrease in postgraduate year (P<.01). Overall, fellows experienced greater mental, physical, and temporal demand than did attending physicians. Small cohort size. Kinematic data and score calculation appear useful in the evaluation of colonoscopy technical skill levels. The kinematic score appears to consistently vary by year of training. Because this assessment is nonsubjective, it may be an improvement over current methods for determination of competence. Ongoing studies are establishing benchmarks and characteristic profiles of skill groups based on kinematics data. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. Telehealth personalized cancer risk communication to motivate colonoscopy in relatives of patients with colorectal cancer: the family CARE Randomized controlled trial.

    PubMed

    Kinney, Anita Y; Boonyasiriwat, Watcharaporn; Walters, Scott T; Pappas, Lisa M; Stroup, Antoinette M; Schwartz, Marc D; Edwards, Sandra L; Rogers, Amy; Kohlmann, Wendy K; Boucher, Kenneth M; Vernon, Sally W; Simmons, Rebecca G; Lowery, Jan T; Flores, Kristina; Wiggins, Charles L; Hill, Deirdre A; Burt, Randall W; Williams, Marc S; Higginbotham, John C

    2014-03-01

    The rate of adherence to regular colonoscopy screening in individuals at increased familial risk of colorectal cancer (CRC) is suboptimal, especially among rural and other geographically underserved populations. Remote interventions may overcome geographic and system-level barriers. We compared the efficacy of a telehealth-based personalized risk assessment and communication intervention with a mailed educational brochure for improving colonoscopy screening among at-risk relatives of patients with CRC. Eligible individuals age 30 to 74 years who were not up-to-date with risk-appropriate screening and were not candidates for genetic testing were recruited after contacting patients with CRC or their next of kin in five states. Enrollees were randomly assigned as family units to either an active, personalized intervention that incorporated evidence-based risk communication and behavior change techniques, or a mailed educational brochure. The primary outcome was medically verified colonoscopy within 9 months of the intervention. Of the 481 eligible and randomly assigned at-risk relatives, 79.8% completed the outcome assessments within 9 months; 35.4% of those in the personalized intervention group and 15.7% of those in the comparison group obtained a colonoscopy. In an intent-to-treat analysis, the telehealth group was almost three times as likely to get screened as the low-intensity comparison group (odds ratio, 2.83; 95% CI, 1.87 to 4.28; P < .001). Persons residing in rural areas and those with lower incomes benefitted at the same level as did urban residents. Remote personalized interventions that consider family history and incorporate evidence-based risk communication and behavior change strategies may promote risk-appropriate screening in close relatives of patients with CRC.

  17. Telehealth Personalized Cancer Risk Communication to Motivate Colonoscopy in Relatives of Patients With Colorectal Cancer: The Family CARE Randomized Controlled Trial

    PubMed Central

    Kinney, Anita Y.; Boonyasiriwat, Watcharaporn; Walters, Scott T.; Pappas, Lisa M.; Stroup, Antoinette M.; Schwartz, Marc D.; Edwards, Sandra L.; Rogers, Amy; Kohlmann, Wendy K.; Boucher, Kenneth M.; Vernon, Sally W.; Simmons, Rebecca G.; Lowery, Jan T.; Flores, Kristina; Wiggins, Charles L.; Hill, Deirdre A.; Burt, Randall W.; Williams, Marc S.; Higginbotham, John C.

    2014-01-01

    Purpose The rate of adherence to regular colonoscopy screening in individuals at increased familial risk of colorectal cancer (CRC) is suboptimal, especially among rural and other geographically underserved populations. Remote interventions may overcome geographic and system-level barriers. We compared the efficacy of a telehealth-based personalized risk assessment and communication intervention with a mailed educational brochure for improving colonoscopy screening among at-risk relatives of patients with CRC. Methods Eligible individuals age 30 to 74 years who were not up-to-date with risk-appropriate screening and were not candidates for genetic testing were recruited after contacting patients with CRC or their next of kin in five states. Enrollees were randomly assigned as family units to either an active, personalized intervention that incorporated evidence-based risk communication and behavior change techniques, or a mailed educational brochure. The primary outcome was medically verified colonoscopy within 9 months of the intervention. Results Of the 481 eligible and randomly assigned at-risk relatives, 79.8% completed the outcome assessments within 9 months; 35.4% of those in the personalized intervention group and 15.7% of those in the comparison group obtained a colonoscopy. In an intent-to-treat analysis, the telehealth group was almost three times as likely to get screened as the low-intensity comparison group (odds ratio, 2.83; 95% CI, 1.87 to 4.28; P < .001). Persons residing in rural areas and those with lower incomes benefitted at the same level as did urban residents. Conclusion Remote personalized interventions that consider family history and incorporate evidence-based risk communication and behavior change strategies may promote risk-appropriate screening in close relatives of patients with CRC. PMID:24449229

  18. Impact of fair bowel preparation quality on adenoma and serrated polyp detection: data from the New Hampshire colonoscopy registry by using a standardized preparation-quality rating.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Robinson, Christina M; Goodrich, Martha; Weiss, Julia E

    2014-09-01

    The effect of colon preparation quality on adenoma detection rates (ADRs) is unclear, partly because of lack of uniform colon preparation ratings in prior studies. The New Hampshire Colonoscopy Registry collects detailed data from colonoscopies statewide, by using a uniform preparation quality scale after the endoscopist has cleaned the mucosa. To compare the overall and proximal ADR and serrated polyp detection rates (SDR) in colonoscopies with differing levels of colon preparation quality. Cross-sectional. New Hampshire statewide registry. Patients undergoing colonoscopy. We examined colon preparation quality for 13,022 colonoscopies, graded by using specific descriptions provided to endoscopists. ADR and SDR are the number of colonoscopies with at least 1 adenoma or serrated polyp (excluding those in the rectum and/or sigmoid colon) detected divided by the total number of colonoscopies, for the preparation categories: optimal (excellent and/or good), fair, and poor. Overall/proximal ADR/SDR. The overall detection rates in examinations with fair colon preparation quality (SDR 8.9%; 95% confidence interval [CI], 7.4-10.7, ADR 27.1%; 95% CI, 24.6-30.0) were similar to rates observed in colonoscopies with optimal preparation quality (SDR 8.8%; 95% CI, 8.3-9.4, ADR 26.3%; 95% CI, 25.6-27.2). This finding also was observed for rates in the proximal colon. A logistic regression model (including withdrawal time) found that proximal ADR was statistically lower in the poor preparation category (odds ratio 0.45; 95% CI, 0.24-0.84; P < .01) than in adequately prepared colons. Homogeneous population. In our sample, there was no significant difference in overall or proximal ADR or SDR between colonoscopies with fair versus optimal colon preparation quality. Poor colon preparation quality may reduce the proximal ADR. Published by Mosby, Inc.

  19. Results of faecal immunochemical test for colorectal cancer screening, in average risk population, in a cohort of 1389 subjects.

    PubMed

    Miuţescu, Bogdan; Sporea, Ioan; Popescu, Alina; Bota, Simona; Iovănescu, Dana; Burlea, Amelia; Mos, Liana; Miuţescu, Eftimie

    2013-01-01

    The aim of this study is to evaluate the usefulness of the fecal immunochemical test (FIT) in colorectal cancer screening, detection of precancerous lesions and early colorectal cancer. The study evaluated asymptomatic patients with average risk (no personal or family antecedents of polyps or colorectal cancer), aged between 50 and 74 years. The presence of the occult haemorrhage was tested with the immunochemical faecal test Hem Check 1 (Veda Lab, France). The subjects were not requested to have any dietary or drug restrictions. Colonoscopy was recommended in all subjects that tested positive. In our study, we had a total of 1389 participants who met the inclusion criteria, with a mean age of 61.2 ± 12.8 years, 565 (40.7%) men and 824 (59.3%) women. FIT was positive in 87 individuals (6.3%). In 57/87 subjects (65.5%) with positive FIT, colonoscopy was performed, while the rest of the subjects refused or delayed the investigation. A number of 5 (8.8%) patients were not able to have a complete colonoscopy, due to neoplastic stenosis. The colonoscopies revealed in 10 cases (0.7%) cancer, in 29 cases (2.1%) advanced adenomas and in 15 cases (1.1%) non advanced adenomas from the total participants in the study. The colonoscopies performed revealed a greater percentage of advanced adenomas in the left colon compared to the right colon, 74.1% vs. 28.6% (p<0.001). In our study, FIT had a positivity rate of 6.3%. The detection rate for advanced neoplasia was 2.8% (0.7% for cancer, 2.1% for advanced adenomas) in our study group. Adherence to colonoscopy for FIT-positive subjects was 65.5%.

  20. Chronic methadone use, poor bowel visualization and failed colonoscopy: A preliminary study

    PubMed Central

    Verma, Siddharth; Fogel, Joshua; Beyda, David J; Bernstein, Brett; Notar-Francesco, Vincent; Mohanty, Smruti R

    2012-01-01

    AIM: To examine effects of chronic methadone usage on bowel visualization, preparation, and repeat colonoscopy. METHODS: In-patient colonoscopy reports from October, 2004 to May, 2009 for methadone dependent (MD) patients were retrospectively evaluated and compared to matched opioid naive controls (C). Strict criteria were applied to exclude patients with risk factors known to cause constipation or gastric dysmotility. Colonoscopy reports of all eligible patients were analyzed for degree of bowel visualization, assessment of bowel preparation (good, fair, or poor), and whether a repeat colonoscopy was required. Bowel visualization was scored on a 4 point scale based on multiple prior studies: excellent = 1, good = 2, fair = 3, or poor = 4. Analysis of variance (ANOVA) and Pearson χ2 test were used for data analyses. Subgroup analysis included correlation between methadone dose and colonoscopy outcomes. All variables significantly differing between MD and C groups were included in both univariate and multivariate logistic regression analyses. P values were two sided, and < 0.05 were considered statistically significant. RESULTS: After applying exclusionary criteria, a total of 178 MD patients and 115 C patients underwent a colonoscopy during the designated study period. A total of 67 colonoscopy reports for MD patients and 72 for C were included for data analysis. Age and gender matched controls were randomly selected from this population to serve as controls in a numerically comparable group. The average age for MD patients was 52.2 ± 9.2 years (range: 32-72 years) years compared to 54.6 ± 15.5 years (range: 20-81 years) for C (P = 0.27). Sixty nine percent of patients in MD and 65% in C group were males (P = 0.67). When evaluating colonoscopy reports for bowel visualization, MD patients had significantly greater percentage of solid stool (i.e., poor visualization) compared to C (40.3% vs 6.9%, P < 0.001). Poor bowel preparation (35.8% vs 9.7%, P < 0.001) and need for repeat colonoscopy (32.8% vs 12.5%, P = 0.004) were significantly higher in MD group compared to C, respectively. Under univariate analysis, factors significantly associated with MD group were presence of fecal particulate [odds ratio (OR), 3.89, 95% CI: 1.33-11.36, P = 0.01] and solid stool (OR, 13.5, 95% CI: 4.21-43.31, P < 0.001). Fair (OR, 3.82, 95% CI: 1.63-8.96, P = 0.002) and poor (OR, 8.10, 95% CI: 3.05-21.56, P < 0.001) assessment of bowel preparation were more likely to be associated with MD patients. Requirement for repeat colonoscopy was also significant higher in MD group (OR, 3.42, 95% CI: 1.44-8.13, P = 0.01). In the multivariate analyses, the only variable independently associated with MD group was presence of solid stool (OR, 7.77, 95% CI: 1.66-36.47, P = 0.01). Subgroup analysis demonstrated a general trend towards poorer bowel visualization with higher methadone dosage. ANOVA analysis demonstrated that mean methadone dose associated with presence of solid stool (poor visualization) was significantly higher compared to mean dosage for clean colon (excellent visualization, P = 0.02) or for those with liquid stool only (good visualization, P = 0.01). CONCLUSION: Methadone dependence is a risk factor for poor bowel visualization and leads to more repeat colonoscopies. More aggressive bowel preparation may be needed in MD patients. PMID:22969198

  1. A Clear Liquid Diet Is Not Mandatory for Polyethylene Glycol-Based Bowel Preparation for Afternoon Colonoscopy in Healthy Outpatients

    PubMed Central

    Jung, Yoon Suk; Seok, Hyo Sun; Song, Chang Seok; Kim, Seong Eun; Lee, Suck Ho; Eun, Chang Soo; Han, Dong Soo; Kim, Yong Soo; Lee, Chang Kyun

    2013-01-01

    Background/Aims A dietary regimen consisting of a clear liquid diet (CLD) for at least 24 hours is recommended for colonoscopy preparation. However, this requirement results in problems in patient compliance with bowel preparation. The aim of this study was to evaluate the efficacy of a CLD compared with a regular diet (RD) for colonoscopy preparation using a polyethylene glycol (PEG) solution. Methods This was a multicenter, randomized, investigator-blind prospective study. A total of 801 healthy outpatients undergoing afternoon colonoscopy were randomized to either a CLD or RD in addition to a 4 L PEG regimen. Results The quality of bowel cleansing was not different between the CLD and RD groups in terms of the proportion with excellent or good preparation. In addition, no significant differences were observed between the two groups for polyp and adenoma detection rates and overall adverse events. Good compliance with bowel preparation was higher in the RD group than in the CLD group. Conclusions A CLD for a full day prior to colonoscopy should not be mandatory for PEG-based bowel preparation. Dietary education concerning the avoidance of high-fiber foods for 3 days before colonoscopy is sufficient, at least for healthy outpatients. PMID:24312709

  2. New-Generation High-Definition Colonoscopes Increase Adenoma Detection when Screening a Moderate-Risk Population for Colorectal Cancer.

    PubMed

    Bond, Ashley; O'Toole, Paul; Fisher, Gareth; Subramanian, Sreedhar; Haslam, Neil; Probert, Chris; Cox, Trevor; Sarkar, Sanchoy

    2017-03-01

    Adenoma detection rate (ADR) is the most important quality indicator for screening colonoscopy, due to its association with colorectal cancer outcomes. As a result, a number of techniques and technologies have been proposed that have the potential to improve ADR. The aim of this study was to assess the potential impact of new-generation high-definition (HD) colonoscopy on ADR within the Bowel Cancer Screening Programme (BCSP). This was a retrospective single-center observational study in patients undergoing an index screening colonoscopy. The examination was performed with either standard-definition colonoscopes (Olympus Q240/Q260 series) or HD colonoscopes (Olympus HQ290 EVIS LUCERA ELITE system) with the primary outcome measures of ADR and mean adenoma per procedure (MAP) between the 2 groups. A total of 395 patients (60.5% male, mean age 66.8 years) underwent screening colonoscopy with 45% performed with HD colonoscopes. The cecal intubation rate was 97.5% on an intention-to-treat basis and ADR was 68.6%. ADR with standard-definition was 63.13%, compared with 75.71% with HD (P = .007). The MAP in the HD group was 2.1 (± 2.0), whereas in the standard-definition group it was 1.6 (± 1.8) (P = .01). There was no significant difference in withdrawal time between the 2 groups. In the multivariate regression model, only HD scopes (P = .03) and male sex (P = .04) independently influenced ADR. Olympus H290 LUCERA ELITE HD colonoscopes improved adenoma detection within the moderate-risk population. A 12% improvement in ADR might be expected to increase significantly the protection afforded by colonoscopy against subsequent colorectal cancer mortality. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Incidental detection of colorectal lesions by FDG PET/CT scans in melanoma patients.

    PubMed

    Young, Christopher J; Zahid, Assad; Choy, Ian; Thompson, John F; Saw, Robyn P M

    2017-11-01

    Increased use of PET/CT scans in oncology patients has raised detection of Colorectal incidentalomas (CIs). The frequency and diagnostic outcomes of identifying these lesions in melanoma patients have not previously been studied. This studies primary objective was to determine the prevalence of CIs found on PET/CT scans in melanoma patients. The secondary objectives were to correlate the PET/CT findings with the pathology found at colonoscopy, and identify which patients were referred for colonoscopy. A retrospective analysis of patients identified from the prospectively collected research database of Melanoma Institute Australia. 2509 patients with melanoma underwent PET/CT scans between 2001 and 2013. The prevalence of CIs, the correlation of lesions, and the survival of patients who underwent colonoscopy versus patients who did not were analyzed. The prevalence of CIs in melanoma patients who had PET/CT scans was 3.2%. Forty-five of the 81 (56%) patients with CIs underwent colonoscopy. Of these, premalignant or malignant disease was found in 58%. Patients with previous metastatic melanoma were significantly less likely to be referred for colonoscopy. Patients undergoing colonoscopy had significantly better survival, as did those without previous distant metastases before the CIs were found, and those without any metastases at the time the CIs were found. These factors were not significant on multivariate analysis. The prevalence of incidental colorectal lesions identified on PET/CT scans in melanoma patients was found to be equivalent to that in the general cancer population. Patients undergoing colonoscopy had better survival than those who did not. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  4. Multitarget stool DNA tests increases colorectal cancer screening among previously noncompliant Medicare patients

    PubMed Central

    Prince, Mark; Lester, Lynn; Chiniwala, Rupal; Berger, Barry

    2017-01-01

    AIM To determine the uptake of noninvasive multitarget stool DNA (mt-sDNA) in a cohort of colorectal cancer (CRC) screening non-compliant average-risk Medicare patients. METHODS This cross sectional primary care office-based study examined mt-sDNA uptake in routine clinical practice among 393 colorectal cancer screening non-compliant Medicare patients ages 50-85 ordered by 77 physicians in a multispecialty group practice (USMD Physician Services, Dallas, TX) from October, 2014-September, 2015. Investigators performed a Health Insurance Portability and Accountability Act compliant retrospective review of electronic health records to identify mt-sDNA use in patients who were either > 10 years since last colonoscopy and/or > 1 year since last fecal occult blood test. Test positive patients were advised to get diagnostic colonoscopy and thereafter patients were characterized by the most clinically significant lesion documented on histopathology of biopsies or excisional tissue. Descriptive statistics were employed. Key outcome measures included mt-sDNA compliance and diagnostic colonoscopy compliance on positive cases. RESULTS Over 12 mo, 77 providers ordered 393 mt-sDNA studies with 347 completed (88.3% compliance). Patient mean age was 69.8 (50-85) and patients were 64% female. Mt-sDNA was negative in 85.3% (296/347) and positive in 14.7% (51/347). Follow-up colonoscopy was performed in 49 positive patients (96.1% colonoscopy compliance) with two patients lost to follow up. Index findings included: colon cancer (4/49, 8.2%), advanced adenomas (21/49, 42.9%), non-advanced adenomas (15/49, 30.6%), and negative results (9/49, 18.4%). The positive predictive value for advanced colorectal lesions was 51.0% and for any colorectal neoplasia was 81.6%. The mean age of patients with colorectal cancer was 70.3 and all CRC's were localized Stage I (2) and Stage II (2), three were located in the proximal colon and one was located in the distal colon. CONCLUSION Mt-sDNA provided medical benefit to screening noncompliant Medicare population. High compliance with mt-sDNA and subsequent follow-up diagnostic colonoscopy identified patients with clinically critical advanced colorectal neoplasia. PMID:28210082

  5. Multitarget stool DNA tests increases colorectal cancer screening among previously noncompliant Medicare patients.

    PubMed

    Prince, Mark; Lester, Lynn; Chiniwala, Rupal; Berger, Barry

    2017-01-21

    To determine the uptake of noninvasive multitarget stool DNA (mt-sDNA) in a cohort of colorectal cancer (CRC) screening non-compliant average-risk Medicare patients. This cross sectional primary care office-based study examined mt-sDNA uptake in routine clinical practice among 393 colorectal cancer screening non-compliant Medicare patients ages 50-85 ordered by 77 physicians in a multispecialty group practice (USMD Physician Services, Dallas, TX) from October, 2014-September, 2015. Investigators performed a Health Insurance Portability and Accountability Act compliant retrospective review of electronic health records to identify mt-sDNA use in patients who were either > 10 years since last colonoscopy and/or > 1 year since last fecal occult blood test. Test positive patients were advised to get diagnostic colonoscopy and thereafter patients were characterized by the most clinically significant lesion documented on histopathology of biopsies or excisional tissue. Descriptive statistics were employed. Key outcome measures included mt-sDNA compliance and diagnostic colonoscopy compliance on positive cases. Over 12 mo, 77 providers ordered 393 mt-sDNA studies with 347 completed (88.3% compliance). Patient mean age was 69.8 (50-85) and patients were 64% female. Mt-sDNA was negative in 85.3% (296/347) and positive in 14.7% (51/347). Follow-up colonoscopy was performed in 49 positive patients (96.1% colonoscopy compliance) with two patients lost to follow up. Index findings included: colon cancer (4/49, 8.2%), advanced adenomas (21/49, 42.9%), non-advanced adenomas (15/49, 30.6%), and negative results (9/49, 18.4%). The positive predictive value for advanced colorectal lesions was 51.0% and for any colorectal neoplasia was 81.6%. The mean age of patients with colorectal cancer was 70.3 and all CRC's were localized Stage I (2) and Stage II (2), three were located in the proximal colon and one was located in the distal colon. Mt-sDNA provided medical benefit to screening noncompliant Medicare population. High compliance with mt-sDNA and subsequent follow-up diagnostic colonoscopy identified patients with clinically critical advanced colorectal neoplasia.

  6. The impact of age, sex and socioeconomic deprivation on outcomes in a colorectal cancer screening programme.

    PubMed

    Mansouri, David; McMillan, Donald C; Grant, Yasmin; Crighton, Emilia M; Horgan, Paul G

    2013-01-01

    Population-based colorectal cancer screening has been shown to reduce cancer specific mortality and is used across the UK. Despite evidence that older age, male sex and deprivation are associated with an increased incidence of colorectal cancer, uptake of bowel cancer screening varies across demographic groups. The aim of this study was to assess the impact of age, sex and deprivation on outcomes throughout the screening process. A prospectively maintained database, encompassing the first screening round of a faecal occult blood test screening programme in a single geographical area, was analysed. Overall, 395,096 individuals were invited to screening, 204,139 (52%) participated and 6079 (3%) tested positive. Of the positive tests, 4625 (76%) attended for colonoscopy and cancer was detected in 396 individuals (9%). Lower uptake of screening was associated with younger age, male sex and deprivation (all p<0.001). Only deprivation was associated with failure to proceed to colonoscopy following a positive test (p<0.001). Despite higher positivity rates in those that were more deprived (p<0.001), the likelihood of detecting cancer in those attending for colonoscopy was lower (8% most deprived vs 10% least deprived, p = 0.003). Individuals who are deprived are less likely to participate in screening, less likely to undergo colonoscopy and less likely to have cancer identified as a result of a positive test. Therefore, this study suggests that strategies aimed at improving participation of deprived individuals in colorectal cancer screening should be directed at all stages of the screening process and not just uptake of the test.

  7. Simulation-Based Training for Colonoscopy

    PubMed Central

    Preisler, Louise; Svendsen, Morten Bo Søndergaard; Nerup, Nikolaj; Svendsen, Lars Bo; Konge, Lars

    2015-01-01

    Abstract The aim of this study was to create simulation-based tests with credible pass/fail standards for 2 different fidelities of colonoscopy models. Only competent practitioners should perform colonoscopy. Reliable and valid simulation-based tests could be used to establish basic competency in colonoscopy before practicing on patients. Twenty-five physicians (10 consultants with endoscopic experience and 15 fellows with very little endoscopic experience) were tested on 2 different simulator models: a virtual-reality simulator and a physical model. Tests were repeated twice on each simulator model. Metrics with discriminatory ability were identified for both modalities and reliability was determined. The contrasting-groups method was used to create pass/fail standards and the consequences of these were explored. The consultants significantly performed faster and scored higher than the fellows on both the models (P < 0.001). Reliability analysis showed Cronbach α = 0.80 and 0.87 for the virtual-reality and the physical model, respectively. The established pass/fail standards failed one of the consultants (virtual-reality simulator) and allowed one fellow to pass (physical model). The 2 tested simulations-based modalities provided reliable and valid assessments of competence in colonoscopy and credible pass/fail standards were established for both the tests. We propose to use these standards in simulation-based training programs before proceeding to supervised training on patients. PMID:25634177

  8. Validity evidence for the Simulated Colonoscopy Objective Performance Evaluation scoring system.

    PubMed

    Trinca, Kristen D; Cox, Tiffany C; Pearl, Jonathan P; Ritter, E Matthew

    2014-02-01

    Low-cost, objective systems to assess and train endoscopy skills are needed. The aim of this study was to evaluate the ability of Simulated Colonoscopy Objective Performance Evaluation to assess the skills required to perform endoscopy. Thirty-eight subjects were included in this study, all of whom performed 4 tasks. The scoring system measured performance by calculating precision and efficiency. Data analysis assessed the relationship between colonoscopy experience and performance on each task and the overall score. Endoscopic trainees' Simulated Colonoscopy Objective Performance Evaluation scores correlated significantly with total colonoscopy experience (r = .61, P = .003) and experience in the past 12 months (r = .63, P = .002). Significant differences were seen among practicing endoscopists, nonendoscopic surgeons, and trainees (P < .0001). When the 4 tasks were analyzed, each showed significant correlation with colonoscopy experience (scope manipulation, r = .44, P = .044; tool targeting, r = .45, P = .04; loop management, r = .47, P = .032; mucosal inspection, r = .65, P = .001) and significant differences in performance between the endoscopist groups, except for mucosal inspection (scope manipulation, P < .0001; tool targeting, P = .002; loop management, P = .0008; mucosal inspection, P = .27). Simulated Colonoscopy Objective Performance Evaluation objectively assesses the technical skills required to perform endoscopy and shows promise as a platform for proficiency-based skills training. Published by Elsevier Inc.

  9. Colonoscopy-associated pneumothorax: a case of tension pneumothorax and review of the literature.

    PubMed

    Zeno, Brian R; Sahn, Steven A

    2006-09-01

    A 64-year-old woman presented with severe abdominal pain and was found to have a large fecolith in the sigmoid colon with resulting bowel obstruction. During a therapeutic colonoscopy, she developed severe shortness of breath and hypoxia, and was found to have a tension pneumothorax. We review the potential mechanisms by which pneumothorax may occur following colonoscopy. In addition, the eight previously published cases are reviewed. Pneumothorax, with or without pneumomediastinum, can occur through a variety of mechanisms following colonoscopy. Although rarely reported, this may represent an underappreciated complication and should be fully investigated in the appropriate setting. Colonoscopy, an exceedingly common procedure, will continue to increase with the aging population. As a result, tension pneumothorax can have a profound effect on the patient outcome and therefore physicians, both gastroenterologists and pulmonologists, should be aware of all the potential problems with this procedure.

  10. High self-efficacy predicts adherence to surveillance colonoscopy in inflammatory bowel disease.

    PubMed

    Friedman, Sonia; Cheifetz, Adam S; Farraye, Francis A; Banks, Peter A; Makrauer, Frederick L; Burakoff, Robert; Farmer, Barbara; Torgersen, Leanne N; Wahl, Kelly E

    2014-09-01

    Patients with extensive ulcerative colitis or Crohn's disease of the colon have an increased risk of colon cancer and require colonoscopic surveillance. In this study, we assessed individual self-efficacy (SE) to estimate the probability of adherence to surveillance colonoscopies. Three hundred seventy-eight patients with ulcerative colitis or Crohn's disease of the colon for at least 7 years and with at least one third of the colon involved participated in this cross-sectional questionnaire study performed at 3 tertiary referral inflammatory bowel disease clinics. Medical charts were abstracted for demographic and clinical variables. The questionnaire contained a group of items assessing SE for undergoing colonoscopy. We validated our 20-question SE scale and used 8 of the items that highlighted scheduling, preparation, and postprocedure recovery, to develop 2 shorter SE scales. All 3 scales were reliable with Cronbach's α ranging from 0.845 to 0.905 and correlated with chart-documented adherence to surveillance colonoscopy (P < 0.001). We then developed logistic regression models to predict adherence to surveillance colonoscopy using each scale separately along with other key variables (i.e., disease location, knowledge of correct adherence intervals, and information sources of patients consulted regarding Crohn's disease and ulcerative colitis) and demonstrated model accuracy up to 74%. SE, as measured by our validated scales, correlates with chart-adherence to surveillance colonoscopy. Our adherence model, which includes SE, predicts adherence with 74% certainty. An 8-item validated clinical questionnaire can be administered to assess whether patients in this population may require further intervention for adherence.

  11. Increasing colonoscopy screening in disparate populations: Results from an evaluation of patient navigation in the New Hampshire Colorectal Cancer Screening Program.

    PubMed

    Rice, Ketra; Gressard, Lindsay; DeGroff, Amy; Gersten, Joanne; Robie, Janene; Leadbetter, Steven; Glover-Kudon, Rebecca; Butterly, Lynn

    2017-09-01

    To investigate uniformly successful results from a statewide program of patient navigation (PN) for colonoscopy, this comparison study evaluated the effectiveness of the PN intervention by comparing outcomes for navigated versus non-navigated patients in one of the community health clinics included in the statewide program. Outcomes measured included screening completion, adequacy of bowel preparation, missed appointments and cancellations, communication of test results, and consistency of follow-up recommendations with clinical guidelines. The authors compared a subset of 131 patients who were navigated to a screening or surveillance colonoscopy with a similar subset of 75 non-navigated patients at one endoscopy clinic. The prevalence and prevalence odds ratios were computed to measure the association between PN and each study outcome measure. Patients in the PN intervention group were 11.2 times more likely to complete colonoscopy than control patients (96.2% vs 69.3%; P<.001), and were 5.9 times more likely to have adequate bowel preparation (P =.010). In addition, intervention patients had no missed appointments compared with 15.6% of control patients, and were 24.8 times more likely to not have a cancellation <24 hours before their appointment (P<.001). All navigated patients and their primary care providers received test results, and all follow-up recommendations were consistent with clinical guidelines compared with 82.4% of patients in the control group (P<.001). PN appears to be effective for improving colonoscopy screening completion and quality in the disparate populations most in need of intervention. To the best of our knowledge, the results of the current study demonstrate some of the strongest evidence for the effectiveness of PN to date, and highlight its value for public health. Cancer 2017;123:3356-66. © 2017 American Cancer Society. © 2017 American Cancer Society.

  12. Improving compliance to colorectal cancer screening using blood and stool based tests in patients refusing screening colonoscopy in Germany.

    PubMed

    Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram

    2014-10-17

    Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.

  13. Colonoscopy-induced acute diverticulitis: myth or reality?

    PubMed

    Gorgun, Emre; Isik, Ozgen; Sapci, Ipek; Aytac, Erman; Abbas, Maher A; Ozuner, Gokhan; Church, James; Steele, Scott R

    2018-07-01

    Colonoscopy in patients with diverticulosis can be technically challenging and limited data exist relating to the risk of post-colonoscopy diverticulitis. Our aim was to evaluate the incidence, management, and outcomes of acute diverticulitis following colonoscopy. Study design is retrospective cohort study. Data were gathered by conducting an automated search of the electronic patient database using current procedural terminology and ICD-9 codes. Patients who underwent a colonoscopy from 2003 to 2012 were reviewed to find patients who developed acute diverticulitis within 30 days after colonoscopy. Patient demographics and colonoscopy-related outcomes were documented, which include interval between colonoscopy and diverticulitis, colonoscopy indication, simultaneous colonoscopic interventions, and follow-up after colonoscopy. From 236,377 colonoscopies performed during the study period, 68 patients (mean age 56 years) developed post-colonoscopy diverticulitis (0.029%; 2.9 per 10,000 colonoscopies). Incomplete colonoscopies were more frequent among patients with a history of previous diverticulitis [n = 10 (29%) vs. n = 3 (9%), p = 0.03]. Mean time to develop diverticulitis after colonoscopy was 12 ± 8 days, and 30 (44%) patients required hospitalization. 34 (50%) patients had a history of diverticulitis prior to colonoscopy. Among those patients, 14 underwent colonoscopy with an indication of surveillance for previous disease. When colonoscopy was performed within 6 weeks of a diverticulitis attack, surgical intervention was required more often when compared with colonoscopies performed after 6 weeks of an acute attack [n = 6 (100%) vs. n = 10 (36%), p = 0.006]. 6 (9%) out of 68 patients received emergency surgical treatment. 15 (24%) out of 62 patients who had non-surgical treatment initially underwent an elective sigmoidectomy at a later date. Recurrent diverticulitis developed in 16 (23%) patients after post-colonoscopy diverticulitis. Post-colonoscopy diverticulitis is a rare, but potentially serious complication. Although a rare entity, possibility of this complication should be kept in mind in patients presenting with symptoms after colonoscopy.

  14. The association of colonoscopy quality indicators with the detection of screen-relevant lesions, adverse events, and postcolonoscopy cancers in an asymptomatic Canadian colorectal cancer screening population.

    PubMed

    Hilsden, Robert J; Dube, Catherine; Heitman, Steven J; Bridges, Ronald; McGregor, S Elizabeth; Rostom, Alaa

    2015-11-01

    Although several quality indicators of colonoscopy have been defined, quality assurance activities should be directed at the measurement of quality indicators that are predictive of key screening colonoscopy outcomes. The goal of this study was to examine the association among established quality indicators and the detection of screen-relevant lesions (SRLs), adverse events, and postcolonoscopy cancers. Historical cohort study. Canadian colorectal cancer screening center. A total of 18,456 asymptomatic men and women ages 40 to 74, at either average risk or increased risk for colorectal cancer because of a family history, who underwent a screening colonoscopy from 2008 to 2010. Using univariate and multivariate analyses, we explored the association among procedural quality indicators and 3 colonoscopy outcomes: detection of SRLs, adverse events, and postcolonoscopy cancers. The crude rates of SRLs, adverse events, and postcolonoscopy cancers were 240, 6.44, and .54 per 1000 colonoscopies, respectively. Several indicators, including endoscopist withdrawal time (OR, 1.3; 95% CI, 1.2-1.4) and cecal intubation rate (OR, 13.9; 95% CI, 1.9-96.9), were associated with the detection of SRLs. No quality indicator was associated with the risk of adverse events. Endoscopist average withdrawal time over 6 minutes (OR, .12; 95% CI, .002-.85) and SRL detection rate over 20% (OR, .17; 95% CI, .03-.74) were associated with a reduced risk of postcolonoscopy cancers. Single-center study. Quality assurance programs should prioritize the measurement of endoscopist average withdrawal time and adenoma (SRL) detection rate. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Longitudinal Rates of Colon Cancer Screening Use in Winnipeg, Canada: The Experience of a Universal Health-Care System with an Organized Colon Screening Program.

    PubMed

    Decker, Kathleen M; Demers, Alain A; Nugent, Zoann; Biswanger, Natalie; Singh, Harminder

    2015-12-01

    We examined trends in colorectal cancer (CRC) screening (fecal occult blood test (FOBT), colonoscopy, and flexible sigmoidoscopy (FS)) and differences in CRC screening by income in a population with an organized CRC screening program and universal health-care coverage. Individuals who had an FOBT, colonoscopy, or FS were identified from the provincial Physician Claims database and the population-based colon cancer screening registry. Trends in age-standardized rates were determined. Logistic regression was performed to explore the association between CRC screening and income quintiles by year. Up-to-date CRC screening (FOBT, colonoscopy, or FS) increased over time for men and women, all age groups, and all income quintiles. Up-to-date CRC screening was very high among 65- to 69- and 70- to 74-year-olds (70% and 73%, respectively). There was a shift toward the use of an FOBT for CRC screening for individuals in the lower income quintiles. The disparity in colonoscopy/FS coverage by income quintile was greater in 2012 than in 1995. Overall, there was no reduction in disparities by income in up-to-date CRC screening nor did the rate of increase in up-to-date CRC screening or FOBT use change after the introduction of the organized provincial CRC screening program. CRC screening is increasing over time for both men and women and all age groups. However, a disparity in up-to-date CRC screening by income persisted even with an organized CRC screening program in a universal health-care setting.

  16. The Effect of Right Colon Retroflexion on Adenoma Detection: A Systematic Review and Meta-analysis.

    PubMed

    Cohen, Jonah; Grunwald, Douglas; Grossberg, Laurie B; Sawhney, Mandeep S

    2017-10-01

    Although colonoscopy with polypectomy can prevent up to 80% of colorectal cancers, a significant adenoma miss rate still exists, particularly in the right colon. Previous studies addressing right colon retroflexion have revealed discordant evidence regarding the benefit of this maneuver on adenoma detection with concomitant concerns about safety and rates of maneuver success. In this meta-analysis, we sought to determine the effect of right colon retroflexion on improving adenoma detection compared with conventional colonoscopy without retroflexion, as well as determine the rates of retroflexion maneuver success and adverse events. Multiple databases including MEDLINE, Embase, and Web of Science were searched for studies on right colon retroflexion and its impact on adenoma detection compared with conventional colonoscopy. Pooled analyses of adenoma detection and retroflexion success were based on mixed-effects and random-effects models with heterogeneity analyses. Eight studies met the inclusion criteria (N=3660). The primary analysis comparing colonoscopy with right-sided retroflexion versus conventional colonoscopy to determine the per-adenoma miss rate in the right colon was 16.9% (95% confidence interval, 12.5%-22.5%). The overall rate of successful retroflexion was 91.9% (95% confidence interval, 86%-95%) and rate of adverse events was 0.03%. Colonoscopy with right-sided retroflexion significantly increases the detection of adenomas in the right colon compared with conventional colonoscopy with a high rate of maneuver success and small risk of adverse events. Thus, reexamination of the right colon in retroflexed view should be strongly considered in future standard of care colonoscopy guidelines for quality improvement in colon cancer prevention.

  17. Relating Stool Microbial Metabolite Levels, Inflammatory Markers and Dietary Behaviors to Screening Colonoscopy Findings in a Racially/Ethnically Diverse Patient Population.

    PubMed

    Bridges, Kristina M; Diaz, Francisco J; Wang, Zhiwen; Ahmed, Ishfaq; Sullivan, Debra K; Umar, Shahid; Buckles, Daniel C; Greiner, K Allen; Hester, Christina M

    2018-02-26

    Colorectal cancer (CRC) is the third leading cause of cancer death for both men and women in the United States, yet it is treatable and preventable. African Americans have higher incidence of CRC than other racial/ethnic groups, however, it is unclear whether this disparity is primarily due to environmental or biological factors. Short chain fatty acids (SCFAs) are metabolites produced by bacteria in the colon and are known to be inversely related to CRC progression. The aim of this study is to investigate how stool SCFA levels, markers of inflammation in stool and dietary intake relate to colonoscopy findings in a diverse patient population. Stool samples from forty-eight participants were analyzed for SCFA levels and inflammatory markers (lysozyme, secretory IgA, lactoferrin). Additionally, participants completed the National Cancer Institute's Diet History Questionnaire II (DHQ II) to report dietary intake over the past year. Subsequently, the majority of participants underwent screening colonoscopy. Our results showed that African Americans had higher total levels of SCFAs in stool than other racial/ethnic groups, significantly lower intake of non-starchy vegetables and similar inflammatory marker expression and colonoscopy outcomes, compared to others. This work is an initial exploration into the biological and clinical factors that may ultimately inform personalized screening approaches and clinical decision-making to improve colorectal cancer disparities for African Americans.

  18. Relating Stool Microbial Metabolite Levels, Inflammatory Markers and Dietary Behaviors to Screening Colonoscopy Findings in a Racially/Ethnically Diverse Patient Population

    PubMed Central

    Bridges, Kristina M.; Diaz, Francisco J.; Wang, Zhiwen; Ahmed, Ishfaq; Sullivan, Debra K.; Umar, Shahid; Buckles, Daniel C.; Greiner, K. Allen; Hester, Christina M.

    2018-01-01

    Colorectal cancer (CRC) is the third leading cause of cancer death for both men and women in the United States, yet it is treatable and preventable. African Americans have higher incidence of CRC than other racial/ethnic groups, however, it is unclear whether this disparity is primarily due to environmental or biological factors. Short chain fatty acids (SCFAs) are metabolites produced by bacteria in the colon and are known to be inversely related to CRC progression. The aim of this study is to investigate how stool SCFA levels, markers of inflammation in stool and dietary intake relate to colonoscopy findings in a diverse patient population. Stool samples from forty-eight participants were analyzed for SCFA levels and inflammatory markers (lysozyme, secretory IgA, lactoferrin). Additionally, participants completed the National Cancer Institute’s Diet History Questionnaire II (DHQ II) to report dietary intake over the past year. Subsequently, the majority of participants underwent screening colonoscopy. Our results showed that African Americans had higher total levels of SCFAs in stool than other racial/ethnic groups, significantly lower intake of non-starchy vegetables and similar inflammatory marker expression and colonoscopy outcomes, compared to others. This work is an initial exploration into the biological and clinical factors that may ultimately inform personalized screening approaches and clinical decision-making to improve colorectal cancer disparities for African Americans. PMID:29495356

  19. Increasing referral rate for screening colonoscopy through patient education and activation at a primary care clinic in New York City.

    PubMed

    Sriphanlop, Pathu; Hennelly, Marie Oliva; Sperling, Dylan; Villagra, Cristina; Jandorf, Lina

    2016-08-01

    Colorectal cancer could be prevented through regular screening. Individuals age 50 and older are recommended to get screened via colonoscopy. Because physician referral is a major predictor of colonoscopy completion, two low-cost, evidence-based interventions were tested to increase referrals by activating patients to self-advocate. This study compared the impact of a pre-visit educational handout that prompts patients to discuss colonoscopy with their physician with the handout plus brief counseling through exit interviews and chart reviews. The main outcome was physician referral. Medical charts were reviewed for eligibility: 130 control patients (Arm 1), 45 patients who received the educational handout and health counseling (Arm 2), and 50 patients who received only the handout (Arm 3). Colonoscopy referral rates increased from 24.6% in Arm 1 to 44.4% and 52.0% in Arms 2 and 3, respectively (p=0.001). The proportion of exit interview participants who discussed colonoscopy with their doctor increased from 68.8% in Arm 1 to 76.5% and 88.9% in Arms 2 and 3, respectively. Results indicate that both interventions are effective at increasing colonoscopy referrals. Results suggest that an educational handout alone is sufficient in prompting patient-initiated discussions about colonoscopy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Colorectal cancer screening: results of a 5-year program in asymptomatic subjects at increased risk.

    PubMed

    Pezzoli, A; Matarese, V; Rubini, M; Simoni, M; Caravelli, G C; Stockbrugger, R; Cifalà, V; Boccia, S; Feo, C; Simone, L; Trevisani, L; Liboni, A; Gullini, S

    2007-01-01

    The province of Ferrara has one of the highest incidences of colorectal cancer (CRC) in Italy. In January 2000, we set up a colonoscopy screening program focussing on first-degree relatives of CRC patients. We now report the results 5 years after the beginning of the project. SCREENEES AND METHODS: In October 1999, we started a campaign stressing the usefulness of colonoscopy for the first-degree relatives of CRC patients. Subjects included in the screening program were aged between 45 and 75 years with at least one first-degree relative affected by CRC. They were invited to an interview where a physician suggested colonoscopy as a screening option. In 5 years, 776 subjects were interviewed and 733 (94.4%) agreed to an endoscopic examination (M/F:375/401; mean age 55 years): 562 colonoscopies were performed. Adenomas and cancers were found in 122 (21.7%) and 12 (2.1%) subjects, respectively. Histological examination in 181 persons with lesions (32.8%) showed (most serious lesion quoted) 47 hyperplastic polyps (26% of all lesions), 2 serrated adenomas (1.1%), 68 tubular adenomas (48%), 24 tubulovillous adenomas (13.3%), 9 adenomas with high grade dysplasia (5%) and 12 adenocarcinomas (6.6%). The majority of the cancers were at an early stage (8 Dukes A and 3 Dukes B). Sedation was used in only 42 colonoscopies (7.5%). A colonoscopy-based screening in this selected high-risk population is feasible. Even without sedation subjects readily agreed to the endoscopic procedure. We identified a significant number of advanced neoplasms and cancers at an early stage suggesting that this could be a useful tool in early identification of CRC.

  1. Screening for colorectal cancer in Tianhe, Guangzhou: results of combining fecal immunochemical tests and risk factors for selecting patients requiring colonoscopy.

    PubMed

    Liao, Yi; Li, Senmao; Chen, Chunyu; He, Xuan; Lin, Feng; Wang, Jianping; Yang, Zuli; Lan, Ping

    2018-05-01

    To explore the performance of a protocol combining fecal immunochemical test (FIT) and a high-risk factor questionnaire (HRFQ) for selecting patients requiring colonoscopy as part of a population-based colorectal cancer (CRC) screening program in China. From 2015 to 2016, we conducted a CRC screening program for all residents aged 45 years or older in Tianhe District, Guangzhou City, China. Participants underwent an FIT and received an HRFQ as part of primary screening. Those with positive FIT and/or HRFQ results were considered to be at high risk and were recommended to undergo colonoscopy. A total of 10 074 subjects were recruited and enrolled in the screening program. In the enrolled population, 17.5% had positive FIT results and 19.4% had positive HRFQ results. Of those recommended to undergo diagnostic colonoscopy, 773 did so. The screening method's overall positive predictive value (PPV) was 4.9% for non-adenomatous polyps, 11.4% for low-risk adenomas (LRAs), 15.9% for high-risk adenomas (HRAs) and 1.6% for CRC. The PPVs of positive FIT results for non-adenomatous polyps, LRAs, HRAs and CRC were 5.2%, 15.9%, 22.5% and 2.5%, respectively. The PPVs of positive HRFQ results for non-adenomatous polyps, LRA, HRA and CRC were 4.1%, 10.2%, 14.3% and 1.4%, respectively. The PPVs associated with combined positive FIT and HRFQ results for non-adenomatous polyps, LRAs, HRAs and CRC were 4.5%, 16.4%, 23.7% and 2.8%, respectively. Our results suggest that this two-step CRC screening strategy, involving a combination of FIT and HRFQ followed by colonoscopy, is useful to identify early-stage CRC. The high detection rates and PPVs for CRC and adenomas encourage this strategy's use in ongoing screening programs.

  2. Modestly increased use of colonoscopy when copayments are waived.

    PubMed

    Khatami, Shabnam; Xuan, Lei; Roman, Rolando; Zhang, Song; McConnel, Charles; Halm, Ethan A; Gupta, Samir

    2012-07-01

    Colorectal cancer (CRC) screening with colonoscopy often requires expensive copayments from patients. The 2010 Patient Protection and Affordable Care Act mandated elimination of copayments for CRC screening, including colonoscopy, but little is known about the effects of copayment elimination on use. The University of Texas employee, retiree, and dependent health plan instituted and promoted a waiver of copayments for screening colonoscopies in fiscal year (FY) 2009; we examined the effects of removing cost sharing on colonoscopy use. We conducted a retrospective cohort study of 59,855 beneficiaries of the University of Texas employee, retiree, and dependent health plan, associated with 16 University of Texas health and nonhealth campuses, ages 50-64 years at any point in FYs 2002-2009 (267,191 person-years of follow-up evaluation). The primary outcome was colonoscopy incidence among individuals with no prior colonoscopy. We compared the age- and sex-standardized incidence ratios for colonoscopy in FY 2009 (after the copayment waiver) with the expected incidence for FY 2009, based on secular trends from years before the waiver. The annual incidence of colonoscopy increased to 9.5% after the copayment was waived, compared with an expected incidence of 8.0% (standardized incidence ratio, 1.18; 95% confidence interval, 1.14-1.23; P < .001). After adjusting for age, sex, and beneficiary status, the copayment waiver remained significantly associated with greater use of colonoscopy, with an adjusted hazard ratio of 1.19 (95% confidence interval, 1.12-1.26). Waiving copayments for colonoscopy screening results in a statistically significant, but modest (1.5%), increase in use. Additional strategies beyond removing financial disincentives are needed to increase use of CRC screening. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Modestly Increased Use of Colonoscopy When Copayments Are Waived

    PubMed Central

    KHATAMI, SHABNAM; XUAN, LEI; ROMAN, ROLANDO; ZHANG, SONG; McCONNEL, CHARLES; HALM, ETHAN A.; GUPTA, SAMIR

    2012-01-01

    BACKGROUND & AIMS Colorectal cancer (CRC) screening with colonoscopy often requires expensive copayments from patients. The 2010 Patient Protection and Affordable Care Act mandated elimination of copayments for CRC screening, including colonoscopy, but little is known about the effects of copayment elimination on use. The University of Texas employee, retiree, and dependent health plan instituted and promoted a waiver of copayments for screening colonoscopies in fiscal year (FY) 2009; we examined the effects of removing cost sharing on colonoscopy use. METHODS We conducted a retrospective cohort study of 59,855 beneficiaries of the University of Texas employee, retiree, and dependent health plan, associated with 16 University of Texas health and nonhealth campuses, ages 50 – 64 years at any point in FYs 2002–2009 (267,191 person-years of follow-up evaluation). The primary outcome was colonoscopy incidence among individuals with no prior colonoscopy. We compared the age- and sex-standardized incidence ratios for colonoscopy in FY 2009 (after the copayment waiver) with the expected incidence for FY 2009, based on secular trends from years before the waiver. RESULTS The annual incidence of colonoscopy increased to 9.5% after the copayment was waived, compared with an expected incidence of 8.0% (standardized incidence ratio, 1.18; 95% confidence interval, 1.14 –1.23; P < .001). After adjusting for age, sex, and beneficiary status, the copayment waiver remained significantly associated with greater use of colonoscopy, with an adjusted hazard ratio of 1.19 (95% confidence interval, 1.12–1.26). CONCLUSIONS Waiving copayments for colonoscopy screening results in a statistically significant, but modest (1.5%), increase in use. Additional strategies beyond removing financial disincentives are needed to increase use of CRC screening. PMID:22401903

  4. Clinical case management and navigation for colonoscopy screening in an academic medical center.

    PubMed

    Cavanagh, Mary F; Lane, Dorothy S; Messina, Catherine R; Anderson, Joseph C

    2013-08-01

    One of 5 nationally funded Centers for Disease Control and Prevention Colorectal Cancer (CRC) Screening Demonstration Programs, Project SCOPE, was conducted at an academic medical center and provided colonoscopy screening at no cost to underserved minority patients from local community health centers. Established barriers to CRC screening (eg, financial, language, transportation) among the target population were addressed through clinical coordination of care by key project staff. The use of a clinician with a patient navigator allowed for the performance of precolonoscopy "telephone visits" instead of office visits to the gastroenterologist in virtually all patients. The clinician elicited information relevant to making screening decisions (eg, past medical and surgical history, focused review of systems, medication/supplement use, CRC screening history). The patient navigator reduced barriers, including, but not limited to, scheduling, transportation, and physical navigation of the medical center on the day of colonoscopy. Preprogram preparation was vital in laying groundwork for the project, yet enhancements to the program were ongoing throughout the screening period. Detailed referral forms from primary care physicians, coupled with information obtained during telephone interviews, facilitated high colonoscopy completion rates and excellent patient satisfaction. Similarly valuable was the employment of a bilingual patient navigator, who provided practical and emotional patient support. Academic medical centers can be efficient models for providing CRC screening to disadvantaged populations. Coordination of care by a preventive medicine department, directing the recruitment, scheduling, prescreening education, and the evaluation and preparation of target populations had an overall positive effect on CRC screening with colonoscopy among patients from a community health center. © 2013 American Cancer Society.

  5. Prior esophagogastroduodenoscopy does not affect the cecal intubation time at bidirectional endoscopies

    PubMed Central

    Öner, Osman Zekai; Demirci, Rojbin Karakoyun; Gündüz, Umut Rıza; Aslaner, Arif; Koç, Ümit; Bülbüller, Nurullah

    2013-01-01

    Bidirectional endoscopy (BE) is often used to assess patients for the reason of anemia or to screen asymptomatic population for malignancy. Limited clinical data favors to perform first the upper gastrointestinal system endoscopy, but its effect to the duration of colonoscopy is yet to be determined. The aim of this retrospective study is to evaluate the effect of upper gastrointestinal system endoscopy on the time to achieve cecal intubation during colonoscopy in patients undergoing BE. Patients of four endoscopists at similar experience levels were retrospectively identified and categorized into the upper gastrointestinal system endoscopy before colonoscopy group (group 1) or the colonoscopy only group (group 2). The demographics, clinical data and the time to achieve cecal intubation for each patient were analyzed. The mean time to achieve cecal intubation in the first group that included 319 cases was 8.4 ± 0.93 minutes and the mean time in the second group that included 1672 cases was 8.56 ± 1.16 minutes. There was no statistically significant difference between the groups. There was also no significant difference between the Group 1 and Group 2 when compared according to which of the four endoscopists performed the procedures. Performing the upper gastrointestinal system endoscopy prior to colonoscopy did not affect the time to achieve cecal intubation. Considering that performing the upper gastrointestinal system endoscopy prior to the colonoscopy is more advantageous in terms of patient comfort and analgesic requirement, beginning to BE with it seems more favorable. PMID:23936601

  6. Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry.

    PubMed

    Anderson, Joseph C; Butterly, Lynn F; Weiss, Julia E; Robinson, Christina M

    2017-06-01

    Similar to achieving adenoma detection rate (ADR) benchmarks to prevent colorectal cancer (CRC), achieving adequate serrated polyp detection rates (SDRs) may be essential to the prevention of CRC associated with the serrated pathway. Previous studies have been based on data from high-volume endoscopists at single academic centers. Based on a hypothesis that ADR is correlated with SDR, we stratified a large, diverse group of endoscopists (n = 77 practicing at 28 centers) into high performers and low performers, based on ADR, to provide data for corresponding target SDR benchmarks. By using colonoscopies in adults aged ≥50 years (4/09-12/14), we stratified endoscopists by high and low ADRs (<15%, 15%-<25%, 25%-<35%, ≥35%) to determine corresponding SDRs by using 2 SDR measures, for screening and surveillance colonoscopies separately: (1) Clinically significant SDR (CSSDR), meaning colonoscopies with any sessile serrated adenoma/polyp (SSA/P), traditional serrated adenoma (TSA), or hyperplastic polyp (HP) >1 cm anywhere in the colon or HP >5 mm in the proximal colon only divided by the total number of screening and surveillance colonoscopies, respectively. (2) Proximal SDR (PSDR) meaning colonoscopies with any serrated polyp (SSA/P, HP, TSA) of any size proximal to the sigmoid colon divided by the total number of screening and surveillance colonoscopies, respectively. A total of 45,996 (29,960 screening) colonoscopies by 77 endoscopists (28 facilities) were included. Moderately strong positive correlation coefficients were observed for screening ADR/CSSDR (P = .69) and ADR/PSDR (P = .79) and a strong positive correlation (P = .82) for CSSDR/PSDR (P < .0001 for all) was observed. For ADR ≥25%, endoscopists' median (interquartile range) screening CSSDR was 6.8% (4.3%-8.6%) and PSDR was 10.8% (8.6%-16.1%). Derived from ADR, the primary colonoscopy quality indicator, our results suggest potential SDR benchmarks (CSSDR = 7% and PSDR = 11%) that may guide adequate serrated polyp detection. Because CSSDR and PSDR are strongly correlated, endoscopists could use the simpler PSDR calculation to assess quality. Published by Elsevier Inc.

  7. What is the most cost-effective population-based cancer screening program for Chinese women?

    PubMed

    Woo, Pauline P S; Kim, Jane J; Leung, Gabriel M

    2007-02-20

    To develop a policy-relevant generalized cost-effectiveness (CE) model of population-based cancer screening for Chinese women. Disability-adjusted life-years (DALYs) averted and associated screening and treatment costs under population-based screening using cervical cytology (cervical cancer), mammography (breast cancer), and fecal occult blood testing (FOBT), sigmoidoscopy, FOBT plus sigmoidoscopy, or colonoscopy (colorectal cancer) were estimated, from which average and incremental CE ratios were generated. Probabilistic sensitivity analysis was undertaken to assess stochasticity, parameter uncertainty, and model assumptions. Cervical, breast, and colorectal cancers were together responsible for 13,556 DALYs (in a 1:4:3 ratio, respectively) in Hong Kong's 3.4 million female population annually. All status quo strategies were dominated, thus confirming the suboptimal efficiency of opportunistic screening. Current patterns of screening averted 471 DALYs every year, which could potentially be more than doubled to 1,161 DALYs under the same screening and treatment budgetary threshold of US $50 million with 100% Pap coverage every 4 years and 30% coverage of colonoscopy every 10 years. With higher budgetary caps, biennial mammographic screening starting at age 50 years can be introduced. Our findings have informed how best to achieve allocative efficiency in deploying scarce cancer care dollars but must be coupled with better integrated care planning, improved intersectoral coordination, increased resources, and stronger political will to realize the potential health and economic gains as demonstrated.

  8. Prevalence of colorectal cancer in acute uncomplicated diverticulitis and the role of the interval colonoscopy.

    PubMed

    Soh, Nicholas Yock Teck; Chia, Daryl Kai Ann; Teo, Nan Zun; Ong, Calvin Jian Ming; Wijaya, Ramesh

    2018-04-16

    Although computed tomography (CT) is the imaging modality of choice for diagnosing colonic diverticulitis today, there remains a risk of colorectal cancer mimicking diverticulitis due to overlapping imaging features. Current practice guidelines recommend interval colonoscopy after diverticulitis to exclude occult malignancy. Some authors have suggested that this may be unnecessary in patients with uncomplicated diverticulitis. The aim of our study was to examine the prevalence of occult colorectal cancer in patients with CT-proven acute uncomplicated diverticulitis in an Asian population. This was a retrospective study of all patients admitted for CT-proven acute uncomplicated diverticulitis between 2007 and 2011 in a single institution. Colonoscopy and histopathology reports were reviewed for patients who underwent interval colonic evaluation. For patients who defaulted follow-up, national health records were reviewed for any subsequent diagnoses of colorectal cancer. The primary outcome was prevalence of colorectal cancer in the cohort. Secondary outcome was prevalence of advanced adenomas. A total of 227 patients with acute uncomplicated diverticulitis were included in our study. One hundred and thirty-five patients (59.5%) underwent follow-up colonic evaluation. The overall prevalence of colorectal cancer was 1.8%, with half these patients presenting with acute colonic obstruction after defaulting follow-up evaluation. Of the patients, 1.5% who underwent colonoscopy had advanced adenomas. Prevalence of colorectal cancer in patients with CT-proven acute uncomplicated diverticulitis may not be as low as previously suggested. We recommend that patients with acute uncomplicated diverticulitis continue to be offered interval colonoscopy until larger studies demonstrate the safety of omission.

  9. Blood RNA biomarker panel detects both left- and right-sided colorectal neoplasms: a case-control study.

    PubMed

    Chao, Samuel; Ying, Jay; Liew, Gailina; Marshall, Wayne; Liew, Choong-Chin; Burakoff, Robert

    2013-07-23

    Colonoscopy is widely regarded to be the gold standard for colorectal cancer (CRC) detection. Recent studies, however, suggest that the effectiveness of colonoscopy is mostly confined to tumors on the left side of the colon (descending, sigmoid, rectum), and that the technology has poor tumor detection for right-sided (cecum, ascending, transverse) lesions. A minimally invasive test that can detect both left-sided and right-sided lesions could increase the effectiveness of screening colonoscopy by revealing the potential presence of neoplasms in the right-sided "blind spot". We previously reported on a seven-gene, blood-based biomarker panel that effectively stratifies a patient's risk of having CRC. For the current study, we assessed the effectiveness of the seven-gene panel for the detection of left- and right-sided CRC lesions. Results were evaluated for 314 patients with CRC (left-sided: TNM I, 65; TNM II, 57; TNM III, 60; TNM IV, 17; unknown, 9. right-sided: TNM I, 28; TNM II, 29; TNM III, 38; TNM IV, 12; unknown, 1 and including two samples with both left and right lesions) and 328 control samples. Blood samples were obtained prior to clinical staging and therapy. Most CRC subjects had localized disease (stages I and II, 58%); regional (stage III) and systemic (stage IV) disease represented 32% and 9%, respectively, of the study population. The panel detected left-sided (74%, 154/208) and right-sided (85%, 92/108) lesions with an overall sensitivity of 78% (215/316) at a specificity of 66% (215/328). Treatable cancer (stages I to III) was detected with left-sided lesion sensitivity of 76% (138/182) and right-sided sensitivity of 84% (80/95). This seven-gene biomarker panel detected right-sided CRC lesions across all cancer stages with a sensitivity that is at least equal to that for left-sided lesions. This study supports the use of this panel as the basis for a patient-friendly, blood-based test that can be easily incorporated into a routine physical examination in advance of colonoscopy to provide a convenient companion diagnostic and a pre-screening alert, ultimately leading to enhanced CRC screening effectiveness.

  10. Clinicopathologic review of polyps biopsied at colonoscopy in Lagos, Nigeria.

    PubMed

    Oluyemi, Aderemi; Awolola, Nicholas; Oyedeji, Olufemi

    2016-01-01

    Colorectal polyps are known precursors of colorectal cancers. The increase in utilization of colonoscopy in Nigeria has meant a rise in the recently reported incidence of these lesions. The aim of this study is to evaluate the clinicopathological profile of colorectal polyps biopsied during the inaugural 12 month period of colonoscopy from a private endoscopy suite in Nigeria. This is a retrospective review of all the clients who had polyps diagnosed at colonoscopy over a 12 month period (August 2014 -July 2015) at a private endoscopy suite in Lagos, Nigeria. This analysis of prospectively collected data was performed using clinical information from the endoscopy logs and pathology database system of a private endoscopy suite based in Lagos, Nigeria. A total of 125 colonoscopies were carried out over the stated period. Of these, 14 individuals had a total of 18 polyps- 4 clients (28.6% of the persons with polyps) had two polyps each. The polyp detection rate was 11.2% while the polyp per colonoscopy rate was 14.4%. Of these clients, males were 10 in number; giving a male to female ratio of 2.5:1. Their ages ranged from 37 to 77 years (mean= 57.3 years). The presenting complaint at colonoscopy was hematochezia in 11 (78.6%), new onset constipation in 2 (14.2%) and peri-anal pain in 1 patient (7.1%). The polyps were distributed as follows; 2 (11.1%) in the ascending colon, 1 (5.6%) each in the transverse and descending colons, 8 (44.4%) in the sigmoid colon, 6(33.3%) located in the rectum. Hence, there was left sided (15 of 18= 83.3%) preponderance. Pathologically, tubular (adenomatous) polyp with or without low grade dysplastic changes was diagnosed in 6 of the 18 polyps (giving an adenoma detection rate of 4.8%), 4 (22.2%) were inflammatory polyps, 1 (5.6%) was malignant and another had the rare inflammatory fibroid polyp. Five (27.8%) of the specimens were reported as non-specific colitis. The study supports the present wisdom that polyps are clearly less prevalent in our environment when compared to the Western world. The increased prevalence with advancing age, in male subjects and of left sided lesions, is also in keeping with previous results from our environment. A case is also advanced for the increased deployment of endoscopy as a tool for the detection of these polyps and ultimately, the reduction of colorectal cancer in our population.

  11. Assessing resident performance and training of colonoscopy in a general surgery training program.

    PubMed

    Hope, William W; Hooks, W Borden; Kilbourne, S Nicole; Adams, Ashley; Kotwall, Cyrus A; Clancy, Thomas V

    2013-05-01

    Recently, the adequacy of endoscopy training in general surgery residency programs has been questioned. Efforts to improve resident endoscopic training and to judge competency are ongoing but not well studied. We assessed resident performance using two assessment tools in colonoscopy in a general surgery residency program. Prospectively collected data were reviewed from consecutive colonoscopies by a single surgeon: September 2008 to June 2011. Colonoscopies performed without residents were excluded. Data included patient demographics, procedural data, and outcomes. Following the colonoscopy, residents were graded by the attending surgeon using up two different assessment tools. Descriptive statistics were calculated and outcomes were compared. Colonoscopies were performed by residents in 100 patients. Average age was 52 (range, 22-79) years. Females made up 66 % of patients, and 63 % were Caucasian. Postgraduate level (PG-Y) 3 level residents performed 72 % of colonoscopies. The average resident participation was 73 % of the procedure. Biopsies were performed in 35 %; adenomatous polyps were found in 17 % and invasive cancer in 1 %. Bowel preparation was deemed good in 76 % of patients. Colonoscopy was completed in 90 % of patients. Reasons for incomplete exam were technical (7 patients), inability to pass a stricture (2 patients), and poor prep (1 patient). For completed full colonoscopies, the average time to reach the cecum was 22 min, and withdrawal time was 13 min. Resident assessments were made in 89 of the colonoscopies using 2 separate assessment tools. There were no mortalities; the morbidity rate was 3 %. Morbidities included a perforation related to a biopsy requiring surgery and partial colectomy, a postpolypectomy bleed requiring repeat colonoscopy with clipping of the bleeding vessel, and a patient with transient bradycardia requiring atropine during the procedure. Using objective assessment tools, overall resident skill and knowledge in performing colonoscopy appears to improve based on increasing PG-Y level, although this was not evident with all categories measured. Methods to assess competency continue to evolve and should be the focus of future research.

  12. Constipation, fiber intake and non-compliance contribute to inadequate colonoscopy bowel preparation: a prospective cohort study.

    PubMed

    Fang, Jun; Fu, Hong Yu; Ma, Dan; Wang, Dong; Liu, Ya Ping; Wang, Yun Feng; Zhu, Chun Ping; Qian, Wei; Bai, Yu; Li, Zhao Shen

    2016-07-01

    Adequate bowel preparation is important for colonoscopy. Currently available evidence on the determinants of poor bowel preparation is largely derived from studies in Western countries. We aimed to identify the risk factors for inadequate bowel preparation for colonoscopy in the Chinese population. In this single-center study, patients admitted to the Outpatient Department between March 2013 and December 2015 and had indications for colonoscopy were prospectively enrolled. Questionnaires were administered to the patients. Their characteristics and procedure-related parameters such as procedure time were recorded. Bowel preparation was assessed using Boston bowel preparation scale score. A total of 409 patients with a mean age of 48.8 ± 12.9 years were enrolled in the study, 60.9% of whom were men. On univariate analysis, poor educational level (P = 0.020), chronic constipation (P = 0.001), taking no physical exercise after medication (P < 0.001), a high-fiber diet during the 24-h period immediately preceding the colonoscopy (P < 0.001), incomplete intake of medication (P < 0.001), the passage of yellow or dark stools before colonoscopy (P < 0.001), waiting time (P = 0.001) and stool frequency after medication (P = 0.048) were significantly associated with inadequate bowel preparation. On multivariate analysis, chronic constipation [odds ratio (OR) 2.05, 95% confidence interval (CI) 1.31-3.23, P = 0.002], incomplete intake of the medication (OR 2.77, 95% CI 1.47-5.21, P = 0.002) and a high-fiber diet within 24 h before colonoscopy (OR 2.15, 95% CI 1.40-3.28, P < 0.001) were independent risk factors for inadequate bowel preparation. Chronic constipation, poor compliance with treatment and high-fiber diet were predictors of poor bowel preparation. Patients with these risk factors require more effective strategies for bowel preparation. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  13. A Web-based Multimedia Program Before Colonoscopy Increased Knowledge and Decreased Anxiety, Sedation Requirement, and Procedure Time.

    PubMed

    Parker, Siddhartha; Zipursky, Jonathan; Ma, Helen; Baumblatt, Geri-Lynn; Siegel, Corey A

    2018-07-01

    Assess the impact of a web-based multimedia patient engagement program on patient anxiety, perception and knowledge about the colonoscopy in addition to procedure outcomes. The success of patients coming for a colonoscopy for colorectal cancer screening is dependent in part on patients' understanding of the preparation and of the procedure. Patients were randomized to use either our institution's standard preprocedure colonoscopy packet or a web-based multimedia patient engagement program (Emmi Solutions) before their scheduled procedure. On the day of colonoscopy, all participants completed a survey including questions to assess knowledge and perception of colonoscopy, in addition to the State Trait Anxiety Inventory. We also collected procedure data including medication doses and procedure time. Patients in the experimental group correctly answered knowledge questions (82%) more often than the control group (74%) (P=0.0003). More than half (58%) of patients in the experimental group felt this intervention reduced their anxiety about the procedure, and the State Trait Anxiety Inventory anxiety score was lower in the experimental group (P=0.026). Patients who viewed the program required less midazolam (3.66 vs. 4.46 mg, P=0.0035) and total procedure time was shorter (24.8 vs. 29 min, P=0.024). A web-based multimedia patient engagement program watched before colonoscopy decreased patient anxiety, medication requirements, and procedure time while increasing knowledge. This intervention could help patients understand and feel more comfortable about colonoscopy leading to increased screening rates while increasing efficiency and decreasing recovery time.

  14. Screening for colorectal cancer with FOBT, virtual colonoscopy and optical colonoscopy: study protocol for a randomized controlled trial in the Florence district (SAVE study)

    PubMed Central

    2013-01-01

    Background Colorectal cancer (CRC) is the most frequent cancer in Europe. Randomized clinical trials demonstrated that screening with fecal occult blood test (FOBT) reduces mortality from CRC. Accordingly, the European Community currently recommends population-based screening with FOBT. Other screening tests, such as computed tomography colonography (CTC) and optical colonoscopy (OC), are highly accurate for examining the entire colon for adenomas and CRC. Acceptability represents a critical determinant of the impact of a screening program. We designed a randomized controlled trial to compare participation rate and diagnostic yield of FOBT, CTC with computer-aided diagnosis, and OC as primary tests for population-based screening. Methods/Design A total of 14,000 subjects aged 55 to 64 years, living in the Florence district and never screened for CRC, will be randomized in three arms: group 1 (5,000 persons) invited to undergo CTC (divided into: subgroup 1A with reduced cathartic preparation and subgroup 1B with standard bowel preparation); group 2 (8,000 persons) invited to undergo a biannual FOBT for three rounds; and group 3 (1,000 persons) invited to undergo OC. Subjects of each group will be invited by mail to undergo the selected test. All subjects with a positive FOBT or CTC test (that is, mass or at least one polyp ≥6 mm) will be invited to undergo a second-level OC. Primary objectives of the study are to compare the participation rate to FOBT, CTC and OC; to compare the detection rate for cancer or advanced adenomas of CTC versus three rounds of biannual FOBT; to evaluate referral rate for OC induced by primary CTC versus three rounds of FOBT; and to estimate costs of the three screening strategies. A secondary objective of the study is to create a biological bank of blood and stool specimens from subjects undergoing CTC and OC. Discussion This study will provide information about participation/acceptability, diagnostic yield and costs of screening with CTC in comparison with the recommended test (FOBT) and OC. Trial registration ClinicalTrials.gov Identifier: NCT01651624. PMID:23497601

  15. Blurry-frame detection and shot segmentation in colonoscopy videos

    NASA Astrophysics Data System (ADS)

    Oh, JungHwan; Hwang, Sae; Tavanapong, Wallapak; de Groen, Piet C.; Wong, Johnny

    2003-12-01

    Colonoscopy is an important screening procedure for colorectal cancer. During this procedure, the endoscopist visually inspects the colon. Human inspection, however, is not without error. We hypothesize that colonoscopy videos may contain additional valuable information missed by the endoscopist. Video segmentation is the first necessary step for the content-based video analysis and retrieval to provide efficient access to the important images and video segments from a large colonoscopy video database. Based on the unique characteristics of colonoscopy videos, we introduce a new scheme to detect and remove blurry frames, and segment the videos into shots based on the contents. Our experimental results show that the average precision and recall of the proposed scheme are over 90% for the detection of non-blurry images. The proposed method of blurry frame detection and shot segmentation is extensible to the videos captured from other endoscopic procedures such as upper gastrointestinal endoscopy, enteroscopy, cystoscopy, and laparoscopy.

  16. Towards designing an optical-flow based colonoscopy tracking algorithm: a comparative study

    NASA Astrophysics Data System (ADS)

    Liu, Jianfei; Subramanian, Kalpathi R.; Yoo, Terry S.

    2013-03-01

    Automatic co-alignment of optical and virtual colonoscopy images can supplement traditional endoscopic procedures, by providing more complete information of clinical value to the gastroenterologist. In this work, we present a comparative analysis of our optical flow based technique for colonoscopy tracking, in relation to current state of the art methods, in terms of tracking accuracy, system stability, and computational efficiency. Our optical-flow based colonoscopy tracking algorithm starts with computing multi-scale dense and sparse optical flow fields to measure image displacements. Camera motion parameters are then determined from optical flow fields by employing a Focus of Expansion (FOE) constrained egomotion estimation scheme. We analyze the design choices involved in the three major components of our algorithm: dense optical flow, sparse optical flow, and egomotion estimation. Brox's optical flow method,1 due to its high accuracy, was used to compare and evaluate our multi-scale dense optical flow scheme. SIFT6 and Harris-affine features7 were used to assess the accuracy of the multi-scale sparse optical flow, because of their wide use in tracking applications; the FOE-constrained egomotion estimation was compared with collinear,2 image deformation10 and image derivative4 based egomotion estimation methods, to understand the stability of our tracking system. Two virtual colonoscopy (VC) image sequences were used in the study, since the exact camera parameters(for each frame) were known; dense optical flow results indicated that Brox's method was superior to multi-scale dense optical flow in estimating camera rotational velocities, but the final tracking errors were comparable, viz., 6mm vs. 8mm after the VC camera traveled 110mm. Our approach was computationally more efficient, averaging 7.2 sec. vs. 38 sec. per frame. SIFT and Harris affine features resulted in tracking errors of up to 70mm, while our sparse optical flow error was 6mm. The comparison among egomotion estimation algorithms showed that our FOE-constrained egomotion estimation method achieved the optimal balance between tracking accuracy and robustness. The comparative study demonstrated that our optical-flow based colonoscopy tracking algorithm maintains good accuracy and stability for routine use in clinical practice.

  17. Unsedation colonoscopy can be not that painful: Evaluation of the effect of "Lamaze method of colonoscopy".

    PubMed

    Yu, Shao-Ping; Lin, Xiao-Dong; Wu, Guang-Yao; Li, Song-Hu; Wen, Zong-Quan; Cen, Xiao-Hong; Huang, Xian-Guang; Huang, Mei-Ting

    2015-10-25

    To evaluate the pain relieving effect of intervention with "Lamaze method of colonoscopy" in the process of colonoscopy. Five hundred and eighty-five patients underwent colonoscopy were randomly divided into three groups, Lamaze group, anesthetic group and control group. Two hundred and twenty-four patients of Lamaze group, the "Lamaze method of colonoscopy" were practiced in the process of colonoscopy. The Lamaze method of colonoscopy is modified from the Lamaze method of childbirth, which helped patients to relieve pain through effective breathing control. One hundred and seventy-eight patients in anesthetic group accepted sedation colonoscopy. For 183 patients in control group, colonoscopy was performed without any intervention. The satisfactory of colon cleaning, intestinal lesions, intubation time, success ratio, pain grading and complications were recorded. All data were statistically analyzed. There were no significant differences at base line of the three groups (P > 0.05). Anesthetic group shows advantage in intubation time than the other two groups (P < 0.05). Lamaze group shows no advantage in intubation time than that in control group (P > 0.05). The anesthetic group showed an apparent advantage in relieving pain (P < 0.01). Therefore, the "Lamaze method of colonoscopy" performed in colonoscopy could relieve pain effectively comparing with control group (P < 0.05). The patients in anesthetic group had the highest incidence of complications (P < 0.05). The performance of the "Lamaze method of colonoscopy" in the process of colonoscopy could relieve patients' pain, minimize the incidence of complications, and is worthy promotion in clinical practice.

  18. The Impact of a Population-Based Screening Program on Income- and Immigration-Related Disparities in Colorectal Cancer Screening.

    PubMed

    Kiran, Tara; Glazier, Richard H; Moineddin, Rahim; Gu, Sumei; Wilton, Andrew S; Paszat, Lawrence

    2017-09-01

    Background: A population-based program promoting the Fecal Occult Blood Test (FOBT) for colorectal cancer screening was introduced in 2008 in Ontario, Canada, where opportunistic screening with colonoscopy had been increasing in frequency. We evaluated the impact of the program on income and immigration-related disparities in screening. Methods: We used linked administrative data to calculate colorectal cancer screening rates for eligible Ontarians in each year between 2001/02 ( n = 2,852,619) and 2013/14 ( n = 4,139,304). We quantified disparities using an "inequality ratio" of screening rates in the most disadvantaged group relative to the most advantaged group. We performed segmented logistic regression analyses stratified by screening modality and adjusted for age, sex, rurality, comorbidity, and morbidity. Results: Between 2001/02 and 2013/14, the income and immigration inequality ratios narrowed from 0.74 to 0.80 and 0.55 to 0.69, respectively. Before the screening program, the income inequality ratio was widening by 1% per year (95% CI 1% to 1%); in the year it was introduced, it narrowed by 4% (95% CI 2% to 7%) and in the years following, it remained stable [0% decrease (95% CI 1% decrease to 0% decrease) per year]. Results were similar for immigration-related disparities. After program introduction, disparities in receiving FOBT were narrowing at a faster rate while disparities in receiving colonoscopy were widening at a slower rate. Conclusions: Introduction of a population-based screening program promoting FOBT for colorectal cancer was associated with only modest improvements in immigration and income-related disparities. Impact: Reducing immigration and income-related disparities should be a focus for future research and policy work. Disparities in Ontario seem to be driven by a higher uptake of colonoscopy among more advantaged groups. Cancer Epidemiol Biomarkers Prev; 26(9); 1401-10. ©2017 AACR . ©2017 American Association for Cancer Research.

  19. Prevalence and features of colorectal lesions among Hispanics: A hospital-based study.

    PubMed

    Ashktorab, Hassan; Laiyemo, Adeyinka O; Lee, Edward; Cruz-Correa, Marcia; Ghuman, Amita; Nouraie, Mehdi; Brim, Hassan

    2015-12-14

    To evaluate the prevalence and characteristics of colorectal adenoma and carcinoma in an inner city Hispanic population. We reviewed the reports of 1628 Hispanic patients who underwent colonoscopy at Howard University from 2000 to 2010. Advanced adenoma was defined as adenoma ≥ 1 cm in size, adenomas with villous histology, high grade dysplasia and/or invasive cancer. Statistical analysis was performed using χ(2) statistics and t-test. The median age of the patients was 54 years, 64.2% were females. Polyps were observed in 489 (30.0%) of patients. Adenoma prevalence was 16.8% (n = 273), advanced adenoma 2.4% (n = 39), and colorectal cancer 0.4% (n = 7). Hyperplastic polyps were seen in 6.6% of the cohort (n = 107). Adenomas predominantly exhibited a proximal colonic distribution (53.7%, n = 144); while hyperplastic polyps were mostly located in the distal colon (70%, n = 75). Among 11.7% (n = 191) patients who underwent screening colonoscopy, the prevalence of colorectal lesions was 21.4% adenoma, 2.6% advanced adenoma; and 8.3% hyperplastic polyps. Our data showed low colorectal cancer prevalence among Hispanics in the Washington DC area. However, the pre-neoplastic pattern of colonic lesions in Hispanics likely points toward a shift in this population that needs to be monitored closely through large epidemiological studies.

  20. Picoprep-3 is a superior colonoscopy preparation to Fleet: a randomized, controlled trial comparing the two bowel preparations.

    PubMed

    Schmidt, Liu-Ming; Williams, Pamela; King, Denis; Perera, Dayashan

    2004-02-01

    Bowel preparations for colonoscopy have to balance the demand for adequate cleansing action of the bowel and patient acceptability. There has been no study comparing Picoprep-3 (sodium picosulfate), a relatively new product, to Fleet (sodium phosphate), a well-studied and widely used preparation. This study was designed to compare the efficacy and patient tolerance of these two bowel preparations for colonoscopy. A randomized, single-blinded, prospective trial was conducted. A total of 400 consecutive patients presenting for elective colonoscopy at St George Private Hospital during a 20-week period were randomly assigned to receive Picoprep-3 or Fleet. Patients were asked to record the effects of the preparation, noting tolerability, taste, and side effects. Two hundred patients were assigned to the Picoprep-3 group and 200 to the Fleet group. Surgeons were blinded to the preparation used and rated the quality of the bowel preparation on a scale of 1 to 5 (1 being the optimal score). Picoprep-3 was found to be better tolerated (P < 0.0001) and better tasting (P < 0.0001) than Fleet. Patients in the Picoprep-3 group reported significantly less nausea (P < 0.001), vomiting (P < 0.004), dizziness (P < 0.01), abdominal pains (P = 0.0005), and thirst (P < 0.0001) associated with the preparation. There was no significant difference in visualization of the colon between the two groups as judged by the two colonoscopists (P = 0.06). Colonoscopy preparation with Picoprep-3 has similar efficacy but superior taste and tolerability compared with Fleet. Picoprep-3 caused less adverse side effects in the study population.

  1. Cost-effectiveness simulation and analysis of colorectal cancer screening in Hong Kong Chinese population: comparison amongst colonoscopy, guaiac and immunologic fecal occult blood testing.

    PubMed

    Wong, Carlos K H; Lam, Cindy L K; Wan, Y F; Fong, Daniel Y T

    2015-10-15

    The aim of this study was to evaluate the cost-effectiveness of CRC screening strategies from the healthcare service provider perspective based on Chinese population. A Markov model was constructed to compare the cost-effectiveness of recommended screening strategies including annual/biennial guaiac fecal occult blood testing (G-FOBT), annual/biennial immunologic FOBT (I-FOBT), and colonoscopy every 10 years in Chinese aged 50 year over a 25-year period. External validity of model was tested against data retrieved from published randomized controlled trials of G-FOBT. Recourse use data collected from Chinese subjects among staging of colorectal neoplasm were combined with published unit cost data ($USD in 2009 price values) to estimate a stage-specific cost per patient. Quality-adjusted life-years (QALYs) were quantified based on the stage duration and SF-6D preference-based value of each stage. The cost-effectiveness outcome was the incremental cost-effectiveness ratio (ICER) represented by costs per life-years (LY) and costs per QALYs gained. In base-case scenario, the non-dominated strategies were annual and biennial I-FOBT. Compared with no screening, the ICER presented $20,542/LYs and $3155/QALYs gained for annual I-FOBT, and $19,838/LYs gained and $2976/QALYs gained for biennial I-FOBT. The optimal screening strategy was annual I-FOBT that attained the highest ICER at the threshold of $50,000 per LYs or QALYs gained. The Markov model informed the health policymakers that I-FOBT every year may be the most effective and cost-effective CRC screening strategy among recommended screening strategies, depending on the willingness-to-pay of mass screening for Chinese population. ClinicalTrials.gov Identifier NCT02038283.

  2. Colometer: a real-time quality feedback system for screening colonoscopy.

    PubMed

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.

  3. Advanced proximal neoplasia of the colon in average-risk adults.

    PubMed

    Rabeneck, Linda; Paszat, Lawrence F; Hilsden, Robert J; McGregor, S Elizabeth; Hsieh, Eugene; M Tinmouth, Jill; Baxter, Nancy N; Saskin, Refik; Ruco, Arlinda; Stock, David

    2014-10-01

    Estimating risk for advanced proximal neoplasia (APN) based on distal colon findings can help identify asymptomatic persons who should undergo examination of the proximal colon after flexible sigmoidoscopy (FS) screening. We aimed to determine the risk of APN by most advanced distal finding among an average-risk screening population. Prospective, cross-sectional study. Teaching hospital and colorectal cancer screening center. A total of 4651 asymptomatic persons at average risk for colorectal cancer aged 50 to 74 years (54.4% women [n = 2529] with a mean [± standard deviation] age of 58.4 ± 6.2 years). All participants underwent a complete colonoscopy, including endoscopic removal of all polyps. We explored associations between several risk factors and APN. Logistic regression was used to identify independent predictors of APN. A total of 142 persons (3.1%) had APN, of whom 85 (1.8%) had isolated APN (with no distal findings). APN was associated with older age, a BMI >27 kg/m(2), smoking, distal advanced adenoma and/or cancer, and distal non-advanced tubular adenoma. Those with a distal advanced neoplasm were more than twice as likely to have APN compared with those without distal lesions. Distal findings used to estimate risk of APN were derived from colonoscopy rather than FS itself. In persons at average risk for colorectal cancer, the prevalence of isolated APN was low (1.8%). Use of distal findings to predict APN may not be the most effective strategy. However, incorporating factors such as age (>65 years), sex, BMI (>27 kg/m(2)), and smoking status, in addition to distal findings, should be considered for tailoring colonoscopy recommendations. Further evaluation of risk stratification approaches in other asymptomatic screening populations is warranted. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Appropriateness of indication and diagnostic yield of colonoscopy: first report based on the 2000 guidelines of the American Society for Gastrointestinal Endoscopy.

    PubMed

    Siddique, Iqbal; Mohan, Krishna; Hasan, Fuad; Memon, Anjum; Patty, Istvan; Al-Nakib, Basil

    2005-11-28

    To assess the appropriateness of referrals and to determine the diagnostic yield of colonoscopy according to the 2000 guidelines of the American Society for Gastrointestinal Endoscopy (ASGE). A total of 736 consecutive patients (415 males, 321 females; mean age 43.6+/-16.6 years) undergoing colonoscopy during October 2001-March 2002 were prospectively enrolled in the study. The 2000 ASGE guidelines were used to assess the appropriateness of the indications for the procedure. Diagnostic yield was defined as the ratio between significant findings detected on colonoscopy and the total number of procedures performed for that indication. The large majority (64%) of patients had colonoscopy for an indication that was considered "generally indicated", it was "generally not indicated" for 20%, and it was "not listed" for 16% in the guidelines. The diagnostic yield of colonoscopy was highest for the "generally indicated" (38%) followed by "not listed" (13%) and "generally not indicated" (5%) categories. In the multivariable analysis, the diagnostic yield was independently associated with the appropriateness of indication that was "generally indicated" (odds ratio=12.3) and referrals by gastroenterologist (odds ratio =1.9). There is a high likelihood of inappropriate referrals for colonoscopy in an open-access endoscopy system. The diagnostic yield of the procedure is dependent on the appropriateness of indication and referring physician's specialty. Certain indications "not listed" in the guidelines have an intermediate diagnostic yield and further studies are required to evaluate whether they should be included in future revisions of the ASGE guidelines.

  5. Can we ease the financial burden of colonoscopy? Using real-time endoscopic assessment of polyp histology to predict surveillance intervals.

    PubMed

    Chandran, S; Parker, F; Lontos, S; Vaughan, R; Efthymiou, M

    2015-12-01

    Polyps identified at colonoscopy are predominantly diminutive (<5 mm) with a small risk (>1%) of high-grade dysplasia or carcinoma; however, the cost of histological assessment is substantial. The aim of this study was to determine whether prediction of colonoscopy surveillance intervals based on real-time endoscopic assessment of polyp histology is accurate and cost effective. A prospective cohort study was conducted across a tertiary care and private community hospital. Ninety-four patients underwent colonoscopy and polypectomy of diminutive (≤5 mm) polyps from October 2012 to July 2013, yielding a total of 159 polyps. Polyps were examined and classified according to the Sano-Emura classification system. The endoscopic assessment (optical diagnosis) of polyp histology was used to predict appropriate colonoscopy surveillance intervals. The main outcome measure was the accuracy of optical diagnosis of diminutive colonic polyps against the gold standard of histological assessment. Optical diagnosis was correct in 105/108 (97.2%) adenomas. This yielded a sensitivity, specificity and positive and negative predictive values (with 95%CI) of 97.2% (92.1-99.4%), 78.4% (64.7-88.7%), 90.5% (83.7-95.2%) and 93% (80.9-98.5%) respectively. Ninety-two (98%) patients were correctly triaged to their repeat surveillance colonoscopy. Based on these findings, a cut and discard approach would have resulted in a saving of $319.77 per patient. Endoscopists within a tertiary care setting can accurately predict diminutive polyp histology and confer an appropriate surveillance interval with an associated financial benefit to the healthcare system. However, limitations to its application in the community setting exist, which may improve with further training and high-definition colonoscopes. © 2015 Royal Australasian College of Physicians.

  6. The incidence of post-colonoscopy colorectal cancer: a retrospective long-term cohort study using a colonoscopy database.

    PubMed

    Nakada, Ayako; Niikura, Ryota; Yamada, Atsuo; Yoshida, Shuntaro; Hirata, Yoshihiro; Koike, Kazuhiko

    2017-06-01

    The cumulative incidence of post-colonoscopy colorectal cancer remains unclear. Our aims were to estimate the incidence of and identify risk factors associated with post-colonoscopy colorectal cancer. We conducted a retrospective cohort study using the colonoscopy database of the Department of Gastroenterology, the University of Tokyo Hospital Records from1995-2012. A cohort of 2544 patients, who received multiple colonoscopies without colorectal cancer findings at first colonoscopy, was selected. The primary outcome was post-colonoscopy colorectal cancer; data were censored at the date of final colonoscopy. We assessed patients' background characteristics, colonoscopy findings, and cancer characteristics, including location and size. The cumulative incidence of colorectal cancer was evaluated, and a Cox proportional hazards model was used to estimate hazard ratios (HRs). Colorectal cancer was identified in seven (0.77/1000 person-years) patients during the mean follow-up period of 3.6 years (maximum, 17 years). The cumulative incidence of colorectal cancer was 0, 0.47, 0.62, and 0.62% at 1, 5, 10, and 15 years, respectively. Cancer was identified in the rectum in five of seven patients. Polyp size >10 mm (HR 5.7, p = 0.023) and intubation time >30 min (HR 11.6, p = 0.003) at first colonoscopy were associated significantly with an increased incidence of post-colonoscopy colorectal cancer. Although several factors were associated with an increased risk of post-colonoscopy colorectal cancer, the incidence of this disease might be low in patients who received at least twice colonoscopy. High proportion of rectal cancer in post-colonoscopy colorectal cancer should be noted.

  7. Magnetic resonance colonography without bowel cleansing: a prospective cross sectional study in a screening population

    PubMed Central

    Kuehle, Christiane A; Langhorst, Jost; Ladd, Susanne C; Zoepf, Thomas; Nuefer, Michael; Grabellus, Florian; Barkhausen, Joerg; Gerken, Guido; Lauenstein, Thomas C

    2007-01-01

    Background and aim To evaluate the diagnostic accuracy of magnetic resonance colonography (MRC) without bowel cleansing in a screening population and compare the results to colonoscopy as a standard of reference. Methods 315 screening patients, older than 50 years with a normal risk profile for colorectal cancer, were included in this study. For MRC, a tagging agent (5.0% Gastrografin, 1.0% barium sulphate, 0.2% locust bean gum) was ingested with each main meal within 2 days prior to MRC. No bowel cleansing was applied. For the magnetic resonance examination, a rectal water enema was administered. Data collection was based on contrast enhanced T1 weighted images and TrueFISP images. Magnetic resonance data were analysed for image quality and the presence of colorectal lesions. Conventional colonoscopy and histopathological samples served as reference. Results In 4% of all colonic segments, magnetic resonance image quality was insufficient because of untagged faecal material. Adenomatous polyps >5 mm were detected by means of MRC, with a sensitivity of 83.0%. Overall specificity was 90.2% (false positive findings in 19 patients). However, only 16 of 153 lesions <5 mm and 9 of 127 hyperplastic polyps could be visualised on magnetic resonance images. Conclusions Faecal tagging MRC is applicable for screening purposes. It provides good accuracy for the detection of relevant (ie, adenomatous) colorectal lesions >5 mm in a screening population. However, refinements to optimise image quality of faecal tagging are needed. PMID:17341542

  8. Perceived Threat and Internet Use Predict Intentions to Get Bowel Cancer Screening (Colonoscopy): Longitudinal Questionnaire Study

    PubMed Central

    Grapendorf, Johannes; Greving, Hannah; Sassenberg, Kai

    2018-01-01

    Background Many people use the Internet for health-related information search, which is known to help regulate their emotional state. However, not much is known yet about how Web-based information search together with negative emotional states (ie, threat of cancer diagnosis) relate to preventive medical treatment decisions (ie, colonoscopy intentions). Objective The aim of this study was to investigate how frequency of health-related Internet use together with perceived threat of a possible (bowel) cancer diagnosis influences intentions to get a colonoscopy. Previous research has shown that people who experience threat preferentially process positive information in an attempt to downregulate the aversive emotional state. The Internet can facilitate this regulatory strategy through allowing self-directed, unrestricted, and thus biased information search. In the context of threat regarding a possible bowel cancer diagnosis, feelings of threat can still be effectively reduced through cancer screening (ie, colonoscopy). We, therefore, predict that in that particular context, feelings of threat should be related to stronger colonoscopy intentions, and that this relationship should be enhanced for people who use the Internet often. Methods A longitudinal questionnaire study was conducted among healthy participants who were approaching or just entering the bowel cancer risk group (aged 45-55 years). Perceived threat of a possible (bowel) cancer diagnosis, frequency of health-related Internet use, and intentions to have a colonoscopy were assessed at 2 time points (6-month time lag between the 2 measurement points T1 and T2). Multiple regression analyses were conducted to test whether threat and Internet use at T1 together predicted colonoscopy intentions at T2. Results In line with our predictions, we found that the threat of a possible (bowel) cancer diagnosis interacted with the frequency of Internet use (both T1) to predict colonoscopy intentions (T2; B=.23, standard error [SE]=0.09, P=.01). For people who used the Internet relatively often (+1 SD), the positive relationship between threat and colonoscopy intentions was significantly stronger (B=.56, SE=0.15, P<.001) compared with participants who used the Internet less often (−1 SD; B=.17, SE=0.09, P=.07). This relationship was unique to Web-based (vs other types of) information search and independent of risk factors (eg, body mass index [BMI] and smoking). Conclusions The results of this study suggest that health-related Internet use can facilitate emotion-regulatory processes. People who feel threatened by a possible (bowel) cancer diagnosis reported stronger colonoscopy intentions, especially when they used the Internet often. We propose that this is because people who experience threat are more likely to search for and process information that allows them to downregulate their aversive emotional state. In the present case of (bowel) cancer prevention, the most effective way to reduce threat is to get screened. PMID:29415872

  9. Health benefits and cost-effectiveness of a hybrid screening strategy for colorectal cancer.

    PubMed

    Dinh, Tuan; Ladabaum, Uri; Alperin, Peter; Caldwell, Cindy; Smith, Robert; Levin, Theodore R

    2013-09-01

    Colorectal cancer (CRC) screening guidelines recommend screening schedules for each single type of test except for concurrent sigmoidoscopy and fecal occult blood test (FOBT). We investigated the cost-effectiveness of a hybrid screening strategy that was based on a fecal immunological test (FIT) and colonoscopy. We conducted a cost-effectiveness analysis by using the Archimedes Model to evaluate the effects of different CRC screening strategies on health outcomes and costs related to CRC in a population that represents members of Kaiser Permanente Northern California. The Archimedes Model is a large-scale simulation of human physiology, diseases, interventions, and health care systems. The CRC submodel in the Archimedes Model was derived from public databases, published epidemiologic studies, and clinical trials. A hybrid screening strategy led to substantial reductions in CRC incidence and mortality, gains in quality-adjusted life years (QALYs), and reductions in costs, comparable with those of the best single-test strategies. Screening by annual FIT of patients 50-65 years old and then a single colonoscopy when they were 66 years old (FIT/COLOx1) reduced CRC incidence by 72% and gained 110 QALYs for every 1000 people during a period of 30 years, compared with no screening. Compared with annual FIT, FIT/COLOx1 gained 1400 QALYs/100,000 persons at an incremental cost of $9700/QALY gained and required 55% fewer FITs. Compared with FIT/COLOx1, colonoscopy at 10-year intervals gained 500 QALYs/100,000 at an incremental cost of $35,100/QALY gained but required 37% more colonoscopies. Over the ranges of parameters examined, the cost-effectiveness of hybrid screening strategies was slightly more sensitive to the adherence rate with colonoscopy than the adherence rate with yearly FIT. Uncertainties associated with estimates of FIT performance within a program setting and sensitivities for flat and right-sided lesions are expected to have significant impacts on the cost-effectiveness results. In our simulation model, a strategy of annual or biennial FIT, beginning when patients are 50 years old, with a single colonoscopy when they are 66 years old, delivers clinical and economic outcomes similar to those of CRC screening by single-modality strategies, with a favorable impact on resources demand. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Variations in colonoscopy practice in Europe: a multicentre descriptive study (EPAGE).

    PubMed

    Harris, Jennifer K; Vader, John-Paul; Wietlisbach, Vincent; Burnand, Bernard; Gonvers, Jean-Jacques; Froehlich, Florian

    2007-01-01

    The volume of colonoscopies performed is increasing and differences in colonoscopy practice over time and between centres have been reported. Examination of current practice is important for bench-marking quality. The objective of this study was to examine variations in colonoscopy practice in endoscopy centres internationally. This observational study prospectively included consecutive patients referred for colonoscopy from 21 centres in 11 countries. Patient, procedure and centre characteristics were collected through questionnaires. Descriptive statistics were performed and the variation between centres while controlling for case-mix was examined. A total of 6004 patients were included in the study. Most colonoscopies (93%; range between centres 70-100%) were performed for diagnostic purposes. The proportion of main indications for colonoscopy showed wide variations between centres, the two most common indications, surveillance and haematochezia, ranging between 7-24% and 5-38%, respectively. High-quality cleansing occurred in 74% (range 51-94%) of patients, and 30% (range 0-100%) of patients received deep sedation. Three-quarters (range 0-100%) of the patients were monitored during colonoscopy, and one-quarter (range 14-35%) underwent polypectomy. Colonoscopy was complete in 89% (range 69-98%) of patients and the median total duration was 20 min (range of centre medians 15-30 min). The variation between centres was not reduced when case-mix was controlled for. This study documented wide variations in colonoscopy practice between centres. Controlling for case-mix did not remove these variations, indicating that centre and procedure characteristics play a role. Centres generally were within the existing guidelines, although there is still some work to be done to ensure that all centres attain the goal of providing high-quality colonoscopy.

  11. Elimination of waste: creation of a successful Lean colonoscopy program at an academic medical center.

    PubMed

    Damle, Aneel; Andrew, Nathan; Kaur, Shubjeet; Orquiola, Alan; Alavi, Karim; Steele, Scott R; Maykel, Justin

    2016-07-01

    Lean processes involve streamlining methods and maximizing efficiency. Well established in the manufacturing industry, they are increasingly being applied to health care. The objective of this study was to determine feasibility and effectiveness of applying Lean principles to an academic medical center colonoscopy unit. Lean process improvement involved training endoscopy personnel, observing patients, mapping the value stream, analyzing patient flow, designing and implementing new processes, and finally re-observing the process. Our primary endpoint was total colonoscopy time (minutes from check-in to discharge) with secondary endpoints of individual segment times and unit colonoscopy capacity. A total of 217 patients were included (November 2013-May 2014), with 107 pre-Lean and 110 post-Lean intervention. Pre-Lean total colonoscopy time was 134 min. After implementation of the Lean process, mean colonoscopy time decreased by 10 % to 121 min (p = 0.01). The three steps of the process affected by the Lean intervention (time to achieve adequate sedation, time to recovery, and time to discharge) decreased from 3.7 to 2.4 min (p < 0.01), 4.0 to 3.4 min (p = 0.09), and 41.2 to 35.4 min (p = 0.05), respectively. Overall, unit capacity of colonoscopies increased from 39.6 per day to 43.6. Post-Lean patient satisfaction surveys demonstrated an average score of 4.5/5.0 (n = 73) regarding waiting time, 4.9/5.0 (n = 60) regarding how favorably this experienced compared to prior colonoscopy experiences, and 4.9/5.0 (n = 74) regarding professionalism of staff. One hundred percentage of respondents (n = 69) stated they would recommend our institution to a friend for colonoscopy. With no additional utilization of resources, a single Lean process improvement cycle increased productivity and capacity of our colonoscopy unit. We expect this to result in increased patient access and revenue while maintaining patient satisfaction. We believe these results are widely generalizable to other colonoscopy units as well as other process-based interventions in health care.

  12. Colonoscopy procedure simulation: virtual reality training based on a real time computational approach.

    PubMed

    Wen, Tingxi; Medveczky, David; Wu, Jackie; Wu, Jianhuang

    2018-01-25

    Colonoscopy plays an important role in the clinical screening and management of colorectal cancer. The traditional 'see one, do one, teach one' training style for such invasive procedure is resource intensive and ineffective. Given that colonoscopy is difficult, and time-consuming to master, the use of virtual reality simulators to train gastroenterologists in colonoscopy operations offers a promising alternative. In this paper, a realistic and real-time interactive simulator for training colonoscopy procedure is presented, which can even include polypectomy simulation. Our approach models the colonoscopy as thick flexible elastic rods with different resolutions which are dynamically adaptive to the curvature of the colon. More material characteristics of this deformable material are integrated into our discrete model to realistically simulate the behavior of the colonoscope. We present a simulator for training colonoscopy procedure. In addition, we propose a set of key aspects of our simulator that give fast, high fidelity feedback to trainees. We also conducted an initial validation of this colonoscopic simulator to determine its clinical utility and efficacy.

  13. Anticipating implementation of colorectal cancer screening in The Netherlands: a nation wide survey on endoscopic supply and demand

    PubMed Central

    2012-01-01

    Background Colorectal cancer (CRC) screening requires sufficient endoscopic resources. The present study aims to determine the Dutch endoscopic production and manpower for 2009, evaluate trends since 2004, determine additional workload which would be caused by implementation of a CRC screening program, and inventory colonoscopy rates performed in other European countries. Methods All Dutch endoscopy units (N = 101) were surveyed for manpower and the numbers of endoscopy procedures performed in 2009. Based on calculations in the report issued by the Dutch Health Council, future additional workload caused by faecal immunochemical test (FIT) screening was estimated. The number of colonoscopies performed in Europe was evaluated by a literature search and an email-inquiry. Results Compared to 2004, there was a 24% increase in total endoscopies (N = 505,226 in 2009), and a 64% increase in colonoscopies (N = 191,339 in 2009) in The Netherlands. The number of endoscopists had increased by 4.6% (N = 583 in 2009). Five years after stepwise implementation of FIT-based CRC screening, endoscopic capacity needs to be increased an additional 15%. A lack of published data on the number of endoscopies performed in Europe was found. Based on our email-inquiry, the number of colonoscopies per 100,000 inhabitants ranged from 126 to 3,031 in 15 European countries. Conclusions Over the last years, endoscopic procedures increased markedly in The Netherlands without a corresponding increase in manpower. A FIT-based CRC screening program requires an estimated additional 15% increase in endoscopic procedures. It is very likely that current colonoscopy density varies widely across European countries. PMID:22280408

  14. Narrative message targets within the decision-making process to undergo screening colonoscopy among Latinos: a qualitative study.

    PubMed

    Hennelly, Marie Oliva; Sly, Jamilia R; Villagra, Cristina; Jandorf, Lina

    2015-06-01

    Colorectal cancer (CRC) is a preventable yet leading cause of cancer mortality among Latinos in the USA. Cultural targeting and narrative messaging are two strategies to increase the low screening colonoscopy rates among Latinos. This study identifies key messages for educational interventions aiming to increase screening colonoscopy used among Latinos and proposes a model to understand the relationship between factors involved in colonoscopy decision-making. Individual in-depth interviews were conducted with 12 Latino participants primarily of Puerto Rican descent on the topics of CRC knowledge, barriers and facilitators to colonoscopy use, and the use of narrative in colorectal health messaging. Knowledge about colorectal anatomy and the anesthesia component of colonoscopy procedure is low. Fear of procedure-related pain and fear of treatment-related burden following a cancer diagnosis are significant barriers to colonoscopy. Fear of disease-related suffering and death following a cancer diagnosis and fear of regret are strong facilitators and can be augmented by cancer narratives. Storytelling is commonly used in Latino culture and is an acceptable method to educate the Latino community about CRC screening via colonoscopy. Machismo is a unique barrier to colonoscopy for Latino men via homophobia and reluctance to seek healthcare. A preliminary model to understand factors in colonoscopy decision-making among Latinos is presented. Counseling practices and educational interventions that use culturally targeted narrative health messaging to mediate fears and increase colonoscopy knowledge may increase screening colonoscopy use among Latinos.

  15. Appropriateness of indication and diagnostic yield of colonoscopy: First report based on the 2000 guidelines of the American Society for Gastrointestinal Endoscopy

    PubMed Central

    Siddique, Iqbal; Mohan, Krishna; Hasan, Fuad; Memon, Anjum; Patty, Istvan; Al-Nakib, Basil

    2005-01-01

    AIM: To assess the appropriateness of referrals and to determine the diagnostic yield of colonoscopy according to the 2000 guidelines of the American Society for Gastrointestinal Endoscopy (ASGE). METHODS: A total of 736 consecutive patients (415 males, 321 females; mean age 43.6±16.6 years) undergoing colonoscopy during October 2001-March 2002 were prospectively enrolled in the study. The 2000 ASGE guidelines were used to assess the appropriateness of the indications for the procedure. Diagnostic yield was defined as the ratio between significant findings detected on colonoscopy and the total number of procedures performed for that indication. RESULTS: The large majority (64%) of patients had colonoscopy for an indication that was considered “generally indicated”, it was “generally not indicated” for 20%, and it was “not listed” for 16% in the guidelines. The diagnostic yield of colonoscopy was highest for the “generally indicated” (38%) followed by “not listed” (13%) and “generally not indicated” (5%) categories. In the multivariable analysis, the diagnostic yield was independently associated with the appropriateness of indication that was “generally indicated” (odds ratio=12.3) and referrals by gastroenterologist (odds ratio =1.9). CONCLUSION: There is a high likelihood of inappropriate referrals for colonoscopy in an open-access endoscopy system. The diagnostic yield of the procedure is dependent on the appropriateness of indication and referring physician’s specialty. Certain indications “not listed” in the guidelines have an intermediate diagnostic yield and further studies are required to evaluate whether they should be included in future revisions of the ASGE guidelines. PMID:16437607

  16. Classifying the Indication for Colonoscopy Procedures: A Comparison of NLP Approaches in a Diverse National Healthcare System.

    PubMed

    Patterson, Olga V; Forbush, Tyler B; Saini, Sameer D; Moser, Stephanie E; DuVall, Scott L

    2015-01-01

    In order to measure the level of utilization of colonoscopy procedures, identifying the primary indication for the procedure is required. Colonoscopies may be utilized not only for screening, but also for diagnostic or therapeutic purposes. To determine whether a colonoscopy was performed for screening, we created a natural language processing system to identify colonoscopy reports in the electronic medical record system and extract indications for the procedure. A rule-based model and three machine-learning models were created using 2,000 manually annotated clinical notes of patients cared for in the Department of Veterans Affairs. Performance of the models was measured and compared. Analysis of the models on a test set of 1,000 documents indicates that the rule-based system performance stays fairly constant as evaluated on training and testing sets. However, the machine learning model without feature selection showed significant decrease in performance. Therefore, rule-based classification system appears to be more robust than a machine-learning system in cases when no feature selection is performed.

  17. Cancer risk awareness and screening uptake in individuals at higher risk for colon cancer: a cross-sectional study

    PubMed Central

    Salimzadeh, Hamideh; Bishehsari, Faraz; Delavari, Alireza; Barzin, Gilda; Amani, Mohammad; Majidi, Azam; Sadjadi, Alireza; Malekzadeh, Reza

    2016-01-01

    Objective We aimed to measure cancer knowledge and feasibility of a screening colonoscopy among a cohort of individuals at higher risk of colon cancer. Methods This study was conducted as part of an ongoing screening cohort, in which first degree relatives (FDRs) of patients with colon cancer are invited to participate in a free of charge screening colonoscopy. We enrolled 1017 FDRs in the study between 2013 and 2014 measuring their data on demographics, cancer knowledge and colonoscopy uptake. A p value of <0.05 was considered statistically significant. Results The relative's mean age was 48.7 years. Only about 28% of FDRs were aware of their increased risk for cancer, near 35.0% had ever heard about colonoscopy with 22% aware of the correct age to start screening. Comparing cancer knowledge of FDRs at high risk versus those at moderate risk, we recorded non-significant differences (p>0.05). Almost two-thirds of FDRs expressed willingness to undergo a colonoscopy and 49.2% completed the procedure, of which 12.8% had advanced neoplasm. Conclusions Our data indicated that remarkable numbers of FDRs were not still informed of their cancer risk or never received a physician recommendation for screening. The desirable uptake at first invitation, which would be higher over successive invitations, supports the feasibility of a family-based recruitment approach for early screening. This has promising implications to introduce targeted screening colonoscopy into the healthcare system in Iran and other developing nations. PMID:27998901

  18. Socioeconomic and other predictors of colonoscopy preparation quality.

    PubMed

    Lebwohl, Benjamin; Wang, Timothy C; Neugut, Alfred I

    2010-07-01

    Suboptimal bowel preparation prior to colonoscopy is a common occurrence, with a deleterious impact on colonoscopy effectiveness. Established risk factors for suboptimal bowel preparation have been proposed, but social factors, such as socioeconomic status and marital status, have not been investigated. The aim of this study was to evaluate sociodemographic factors, including insurance status and marital status, as predictive of suboptimal preparation. We analyzed a database of 12,430 consecutive colonoscopies during a 28-month period at Columbia University Medical Center. We collected the following variables: age, gender, indication for colonoscopy, location (inpatient vs. outpatient), race, marital status, and Medicaid status. Preparation quality was recorded and dichotomized as optimal or suboptimal. We employed multivariate regression to determine independent risk factors for suboptimal bowel preparation. Among the 10,921 examinations in which bowel preparation was recorded, suboptimal preparation occurred in 34% of Medicaid patients versus 18% of non-Medicaid patients (P < 0.0001); this remained significant in the multivariate analysis (odds ratio (OR) 1.84, 95% CI 1.61-2.11). Married patients had decreased rates of suboptimal preparation (OR 0.89, 95% CI 0.80-0.98). Other variables associated with suboptimal preparation included increased age (OR per 10 years 1.09, 95% CI 1.05-1.14), male gender (OR 1.44, 95% CI 1.31-1.59), inpatient status (OR 1.51, 95% CI 1.26-1.80), and later time of day (OR 1.89, 95% CI 1.71-2.09). Unmarried status and Medicaid status are predictive of suboptimal bowel preparation. Future studies are warranted to identify how these social conditions predict bowel preparation quality and to implement interventions to optimize bowel preparation in vulnerable populations.

  19. Adenoma Prevalence and Distribution Among US Latino Subgroups Undergoing Screening Colonoscopy.

    PubMed

    Chablani, Sumedha V; Jandorf, Lina; DuHamel, Katherine; Lee, Kristen K; Sriphanlop, Pathu; Villagra, Cristina; Itzkowitz, Steven H

    2017-06-01

    Colorectal cancer (CRC) is the second leading malignancy diagnosed among US Latinos. Latinos in the USA represent a heterogeneous amalgam of subgroups varying in genetic background, culture, and socioeconomic status. Little is known about the frequency of CRC precursor lesions found at screening colonoscopy among Latino subgroups. The aim was to determine the prevalence and distribution of histologically confirmed adenomas found at screening colonoscopy among average-risk, asymptomatic US Latinos according to their subgroup and socio-demographic background. Cross-sectional analysis of pathological findings resulting from screening colonoscopy among average-risk, asymptomatic US Latinos aged ≥50 in two prospective randomized controlled trials at an academic medical center. Among the 561 Latinos who completed screening colonoscopy, the two largest subgroups were Puerto Ricans and Dominicans. The findings among both subgroups were: adenomas 30.6%, proximal adenomas 23.5%, advanced adenomas 12.0%, and proximal advanced adenomas 8.9%. These rates are at least as high as those found at screening colonoscopy among US whites. While Puerto Ricans were more likely than Dominicans to be born in the USA, speak English, be acculturated, have a smoking history, and be obese, there were no significant differences in adenoma rates between these subgroups. The prevalence of adenomas, advanced adenomas, and proximal neoplasia was high among both subgroups. These findings have implications for CRC screening and surveillance among the increasingly growing Latino population in the USA.

  20. Surveillance of colonic polyps: Are we getting it right?

    PubMed Central

    Bonnington, Stewart N; Rutter, Matthew D

    2016-01-01

    Colorectal cancer (CRC) is the third most commonly diagnosed cancer worldwide. The identification of colonic polyps can reduce CRC mortality through earlier diagnosis of cancers and the removal of polyps: the precursor lesion of CRC. Following the finding and removal of colonic polyps at an initial colonoscopy, some patients are at an increased risk of developing CRC in the future. This is the rationale for post-polypectomy surveillance colonoscopy. However, not all individuals found to have colonic adenomas have a risk of CRC higher than that of the general population. This review examines the literature on post-polypectomy surveillance including current international clinical guidelines. The potential benefits of surveillance procedures must be weighed against the burden of colonoscopy: resource use, the potential for patient discomfort, and the risk of complications. Therefore surveillance colonoscopy is best utilised in a selected group of individuals at a high risk of developing cancer. Further study is needed into the specific factors conferring higher risk as well as the efficacy of surveillance in mitigating this risk. Such evidence will better inform clinicians and patients of the relative benefits of colonoscopic surveillance for the individual. In addition, the decision to continue with surveillance must be informed by the changing profile of risks and benefits of further procedures with the patient’s advancing age. PMID:26877600

  1. Surveillance of colonic polyps: Are we getting it right?

    PubMed

    Bonnington, Stewart N; Rutter, Matthew D

    2016-02-14

    Colorectal cancer (CRC) is the third most commonly diagnosed cancer worldwide. The identification of colonic polyps can reduce CRC mortality through earlier diagnosis of cancers and the removal of polyps: the precursor lesion of CRC. Following the finding and removal of colonic polyps at an initial colonoscopy, some patients are at an increased risk of developing CRC in the future. This is the rationale for post-polypectomy surveillance colonoscopy. However, not all individuals found to have colonic adenomas have a risk of CRC higher than that of the general population. This review examines the literature on post-polypectomy surveillance including current international clinical guidelines. The potential benefits of surveillance procedures must be weighed against the burden of colonoscopy: resource use, the potential for patient discomfort, and the risk of complications. Therefore surveillance colonoscopy is best utilised in a selected group of individuals at a high risk of developing cancer. Further study is needed into the specific factors conferring higher risk as well as the efficacy of surveillance in mitigating this risk. Such evidence will better inform clinicians and patients of the relative benefits of colonoscopic surveillance for the individual. In addition, the decision to continue with surveillance must be informed by the changing profile of risks and benefits of further procedures with the patient's advancing age.

  2. Prevalence and features of colorectal lesions among Hispanics: A hospital-based study

    PubMed Central

    Ashktorab, Hassan; Laiyemo, Adeyinka O; Lee, Edward; Cruz-Correa, Marcia; Ghuman, Amita; Nouraie, Mehdi; Brim, Hassan

    2015-01-01

    AIM: To evaluate the prevalence and characteristics of colorectal adenoma and carcinoma in an inner city Hispanic population. METHODS: We reviewed the reports of 1628 Hispanic patients who underwent colonoscopy at Howard University from 2000 to 2010. Advanced adenoma was defined as adenoma ≥ 1 cm in size, adenomas with villous histology, high grade dysplasia and/or invasive cancer. Statistical analysis was performed using χ2 statistics and t-test. RESULTS: The median age of the patients was 54 years, 64.2% were females. Polyps were observed in 489 (30.0%) of patients. Adenoma prevalence was 16.8% (n = 273), advanced adenoma 2.4% (n = 39), and colorectal cancer 0.4% (n = 7). Hyperplastic polyps were seen in 6.6% of the cohort (n = 107). Adenomas predominantly exhibited a proximal colonic distribution (53.7%, n = 144); while hyperplastic polyps were mostly located in the distal colon (70%, n = 75). Among 11.7% (n = 191) patients who underwent screening colonoscopy, the prevalence of colorectal lesions was 21.4% adenoma, 2.6% advanced adenoma; and 8.3% hyperplastic polyps. CONCLUSION: Our data showed low colorectal cancer prevalence among Hispanics in the Washington DC area. However, the pre-neoplastic pattern of colonic lesions in Hispanics likely points toward a shift in this population that needs to be monitored closely through large epidemiological studies. PMID:26673447

  3. Helicobacter Pylori Associated Gastritis Increases Risk of Colorectal Polyps: a Hospital Based-Cross-Sectional Study in Nakhon Ratchasima Province, Northeastern Thailand.

    PubMed

    Tongtawee, Taweesak; Kaewpitoon, Soraya; Kaewpitoon, Natthawut; Dechsukhum, Chavaboon; Leeanansaksiri, Wilairat; Loyd, Ryan A; Matrakool, Likit; Panpimanmas, Sukij

    2016-01-01

    Colorectal polyps are common in Thailand, particularly in the northeastern region. The present study aimed to determine any correlation between Helicobacter pylori-associated gastritis and colorectal polyps in the Thai population. A total of 303 patients undergoing esophagogastroduodenoscopy with colonoscopy for investigation of chronic abdominal pain participated in this study from November 2014 to October 2015. A diagnosis of Helicobacter pylori associated gastritis was made if the bacteria were seen on histopathological examination and a rapid urease test was positive. Colorectal polyps were confirmed by histological examination of colorectal biopsies. Patient demographic data were analyzed for correlations. The prevalence of colorectal polyps was 77 (25.4%), lesions being found more frequently in Helicobacter pylori infected patients than non-infected subjects [38.4% vs. 12.5%; Odds Ratio (OR) (95% CI): 2.26 (1.32 - 3.86), p < 0.01]. Patients with Helicobacter pylori - associated gastritis were at high risk of having adenomas featuring dysplasia [OR (95% CI): 1.15 (1.16 - 7.99); P = 0.02]. There was no varaition in location of polyps, age group, sex and gastric lesions with respect to Helicobacter pylori status. This study showed that Helicobacter pylori associated gastritis is associated with an increased risk of colorectal polyps, especially adenomas with dysplasia in the Thai population. Patients with Helicobacter pylori-associated gastritis may benefit from concurrent colonoscopy for diagnosis of colorectal polyps as a preventive and early treatment for colorectal cancer.

  4. Colonoscopy quality assurance in Ontario: Systematic review and clinical practice guideline

    PubMed Central

    Tinmouth, Jill; Kennedy, Erin B; Baron, David; Burke, Mae; Feinberg, Stanley; Gould, Michael; Baxter, Nancy; Lewis, Nancy

    2014-01-01

    Colonoscopy is fundamental to the diagnosis and management of digestive diseases and plays a key role in colorectal cancer (CRC) screening and diagnosis. Therefore, it is important to ensure that colonoscopy is of high quality. The present guidance document updates the evidence and recommendations in Cancer Care Ontario’s 2007 Colonoscopy Standards, and was conducted under the aegis of the Program in Evidence-Based Care. It is intended to support quality improvement for colonoscopies for all indications, including follow-up to a positive fecal occult blood test, screening for individuals who have a family history of CRC and those at average risk, investigation for symptomatic patients, and surveillance of those with a history of adenomatous polyps or CRC. A systematic review was performed to evaluate the existing evidence concerning the following three key aspects of colonoscopy: physician endoscopist training and maintenance of competency; institutional quality assurance parameters; and colonoscopy quality indicators and auditable outcomes. Where appropriate, indicators were designated quality indicators (where there was sufficient evidence to recommend a specific target) and auditable outcomes (insufficient evidence to recommend a specific target, but which should be monitored for quality assurance purposes). The guidance document may be used to support colonoscopy quality assurance programs to improve the quality of colonoscopy regardless of indication. Improvements in colonoscopy quality are anticipated to improve important outcomes in digestive diseases, such as reduction of the incidence of and mortality from CRC. PMID:24839621

  5. Do factors related to endogenous and exogenous estrogens modify the relationship between obesity and risk of colorectal adenomas in women?

    PubMed

    Wolf, Lesley A; Terry, Paul D; Potter, John D; Bostick, Roberd M

    2007-04-01

    Obesity has consistently been associated with increased colorectal cancer risk in men, but not in women. In the absence of postmenopausal hormone use (PMH), adipose-derived estrogen is the primary determinant of circulating estrogen levels in postmenopausal women, perhaps ameliorating the mitogenic effects of obesity in this group. Using data from a case-control study in the United States, we examined associations among obesity, potential modifying effects of factors related to endogenous and exogenous estrogen levels, and risk of colorectal adenoma. Cases (n = 219) were women of ages 30 to 74 years with colonoscopy proven, incident, sporadic, pathology-confirmed, adenomatous polyps of the colon and rectum. Two control groups were recruited: colonoscopy-confirmed polyp-free women (n = 438) and age- and zip code frequency-matched women randomly selected from the community (n = 247). Multivariate odds ratios and 95% confidence intervals (95% CI) for obese [body mass index (BMI) >or=30.0; compared with nonobese, BMI <25.0] premenopausal women were 2.09 (95% CI, 0.81-5.41) versus colonoscopy controls, and 5.18 (95% CI, 1.40-19.32) versus population controls. For PMH users, the corresponding odds ratios were 0.29 (95% CI, 0.12-0.70) versus colonoscopy controls and 0.64 (95% CI, 0.23-1.83) versus population controls. There was no significant association of BMI with adenoma risk for PMH nonusers. Findings for waist-to-hip ratio were similar to those for BMI. These data support the hypothesis that risk for colorectal adenoma may be increased with obesity among premenopausal women but decreased among postmenopausal women, especially if they also take PMH.

  6. Safety of a 1-Day Polyethylene Glycol 3350 Bowel Preparation for Colonoscopy in Children.

    PubMed

    Sahn, Benjamin; Chen-Lim, Mei Lin; Ciavardone, Denise; Farace, Lisa; Jannelli, Frances; Nieberle, Megan; Ely, Elizabeth; Zhang, Xuemei; Kelsen, Judith; Puma, Anita; Mamula, Petar

    2016-07-01

    Electrolyte-free polyethylene glycol powder (PEG-3350) has been widely used for colonoscopy preparation (prep); however, limited safety data on electrolyte changes exists with 1-day prep regimens. The primary aim of this study was to determine the proportion of patients with significant serum chemistry abnormalities before and at the time of colonoscopy. Secondary aims included evaluation of prep tolerance and bowel cleansing efficacy. We performed a prospective descriptive observational study of pediatric patients scheduled for outpatient colonoscopy who received our standard 1-day, weight-based 4 g/kg PEG-3350 prep with a single stimulant laxative dose and had serum chemistry testing within 60 days before and at the time of colonoscopy. A standardized bowel cleanliness tool (Aronchick scale) was completed by the endoscopist. One hundred fifty-five patients had serum electrolytes data pre- and postprep. Comparison of each patient's chemistries demonstrated statistical equivalence with the 1 exception of blood urea nitrogen levels (P = 0.56). Hypokalemia was detected postprep in 37 subjects (24%), but none had a serum level <3.3 mmol/L, which was deemed to be of no clinical significance. Five patients were hypoglycemic post prep; 3 were 7 years or younger (P = 0.02). The colon cleanliness rating was excellent or good in 77% and suboptimal in 23% of patients. A 1-day, weight-based PEG-3350 bowel prep in children appears safe. Changes in electrolyte levels and renal function were not clinically significant. Children of 7 years or younger seem to be at a higher risk of hypoglycemia compared with older children.

  7. Population-based colorectal cancer screening programmes using a faecal immunochemical test: should faecal haemoglobin cut-offs differ by age and sex?

    PubMed

    Arana-Arri, Eunate; Idigoras, Isabel; Uranga, Begoña; Pérez, Raquel; Irurzun, Ana; Gutiérrez-Ibarluzea, Iñaki; Fraser, Callum G; Portillo, Isabel

    2017-08-29

    The Basque Colorectal Cancer Screening Programme has both high participation rate and high compliance rate of colonoscopy after a positive faecal occult blood test (FIT). Although, colorectal cancer (CRC) screening with biannual (FIT) has shown to reduce CRC mortality, the ultimate effectiveness of the screening programmes depends on the accuracy of FIT and post-FIT colonoscopy, and thus, harms related to false results might not be underestimated. Current CRC screening programmes use a single faecal haemoglobin concentration (f-Hb) cut-off for colonoscopy referral for both sexes and all ages. We aimed to determine optimum f-Hb cut-offs by sex and age without compromising neoplasia detection and interval cancer proportion. Prospective cohort study using a single-sample faecal immunochemical test (FIT) on 444,582 invited average-risk subjects aged 50-69 years. A result was considered positive at ≥20 μg Hb/g faeces. Outcome measures were analysed by sex and age for a wide range of f-Hb cut-offs. We analysed 17,387 positive participants in the programme who underwent colonoscopy. Participation rate was 66.5%. Men had a positivity rate for f-Hb of 8.3% and women 4.8% (p < 0.0001). The detection rate for advanced neoplasia (cancer plus advanced adenoma) was 44.0‰ for men and 15.9‰ for women (p < 0.0001). The number of colonoscopies required decreased in both sexes and all age groups through increasing the f-Hb cut-off. However, the loss in CRC detection increased by up to 28.1% in men and 22.9% in women. CRC missed were generally at early stages (Stage I-II: from 70.2% in men to 66.3% in women). This study provides detailed outcomes in men and women of different ages at a range of f-Hb cut-offs. We found differences in positivity rates, neoplasia detection rate, number needed to screen, and interval cancers in men and women and in younger and older groups. However, there are factors other than sex and age to consider when consideration is given to setting the f-Hb cut-off.

  8. [Virtual colonoscopy is now reality].

    PubMed

    Pedersen, Bodil Ginnerup; Achiam, Michael P; Arnesen, Regnar Bøge

    2005-10-31

    Virtual colonoscopy involves a helical CT or MR scan of the abdomen and pelvis to detect colorectal polyps and cancer. Both modalities have shown promising sensitivity in revealing larger polyps, in comparison with colonoscopy. Caution should be exercised in its clinical implementation due to significant interobserver variation and individual learning curves. A Danish study indicates that CT colonography (CTC) can be performed cost-effectively compared to colonoscopy. CTC is recommended in preference to double-contrast barium enema after incomplete colonoscopy.

  9. Cost-effectiveness of population-based screening for colorectal cancer: a comparison of guaiac-based faecal occult blood testing, faecal immunochemical testing and flexible sigmoidoscopy

    PubMed Central

    Sharp, L; Tilson, L; Whyte, S; O'Ceilleachair, A; Walsh, C; Usher, C; Tappenden, P; Chilcott, J; Staines, A; Barry, M; Comber, H

    2012-01-01

    Background: Several colorectal cancer-screening tests are available, but it is uncertain which provides the best balance of risks and benefits within a screening programme. We evaluated cost-effectiveness of a population-based screening programme in Ireland based on (i) biennial guaiac-based faecal occult blood testing (gFOBT) at ages 55–74, with reflex faecal immunochemical testing (FIT); (ii) biennial FIT at ages 55–74; and (iii) once-only flexible sigmoidoscopy (FSIG) at age 60. Methods: A state-transition model was used to estimate costs and outcomes for each screening scenario vs no screening. A third party payer perspective was adopted. Probabilistic sensitivity analyses were undertaken. Results: All scenarios would be considered highly cost-effective compared with no screening. The lowest incremental cost-effectiveness ratio (ICER vs no screening €589 per quality-adjusted life-year (QALY) gained) was found for FSIG, followed by FIT (€1696) and gFOBT (€4428); gFOBT was dominated. Compared with FSIG, FIT was associated with greater gains in QALYs and reductions in lifetime cancer incidence and mortality, but was more costly, required considerably more colonoscopies and resulted in more complications. Results were robust to variations in parameter estimates. Conclusion: Population-based screening based on FIT is expected to result in greater health gains than a policy of gFOBT (with reflex FIT) or once-only FSIG, but would require significantly more colonoscopy resources and result in more individuals experiencing adverse effects. Weighing these advantages and disadvantages presents a considerable challenge to policy makers. PMID:22343624

  10. Estimating the Effect of Targeted Screening Strategies: An Application to Colonoscopy and Colorectal Cancer.

    PubMed

    Thomas, Duncan C

    2017-07-01

    Screening behavior depends on previous screening history and family members' behaviors, which can act as both confounders and intermediate variables on a causal pathway from screening to disease risk. Conventional analyses that adjust for these variables can lead to incorrect inferences about the causal effect of screening if high-risk individuals are more likely to be screened. Analyzing the data in a manner that treats screening as randomized conditional on covariates allows causal parameters to be estimated; inverse probability weighting based on propensity of exposure scores is one such method considered here. I simulated family data under plausible models for the underlying disease process and for screening behavior to assess the performance of alternative methods of analysis and whether a targeted screening approach based on individuals' risk factors would lead to a greater reduction in cancer incidence in the population than a uniform screening policy. Simulation results indicate that there can be a substantial underestimation of the effect of screening on subsequent cancer risk when using conventional analysis approaches, which is avoided by using inverse probability weighting. A large case-control study of colonoscopy and colorectal cancer from Germany shows a strong protective effect of screening, but inverse probability weighting makes this effect even stronger. Targeted screening approaches based on either fixed risk factors or family history yield somewhat greater reductions in cancer incidence with fewer screens needed to prevent one cancer than population-wide approaches, but the differences may not be large enough to justify the additional effort required. See video abstract at, http://links.lww.com/EDE/B207.

  11. Deep Learning Localizes and Identifies Polyps in Real Time with 96% Accuracy in Screening Colonoscopy.

    PubMed

    Urban, Gregor; Tripathi, Priyam; Alkayali, Talal; Mittal, Mohit; Jalali, Farid; Karnes, William; Baldi, Pierre

    2018-06-18

    The benefit of colonoscopy for colorectal cancer prevention depends on the adenoma detection rate (ADR). The ADR should reflect adenoma prevalence rate, estimated to be greater than 50% among the screening-age population. Yet the rate of adenoma detection by colonoscopists varies from 7% to 53%. It is estimated that every 1% increase in ADR reduces the risk of interval colorectal cancers by 3-6%. New strategies are needed to increase the ADR during colonoscopy. We tested the ability of computer-assisted image analysis, with convolutional neural networks (a deep learning model for image analysis), to improve polyp detection, a surrogate of ADR. We designed and trained deep convolutional neural networks (CNN) to detect polyps using a diverse and representative set of 8641 hand labeled images from screening colonoscopies collected from over 2000 patients. We tested the models on 20 colonoscopy videos with a total duration of 5 hours. Expert colonoscopists were asked to identify all polyps in 9 de-identified colonoscopy videos, selected from archived video studies, either with or without benefit of the CNN overlay. Their findings were compared with those of the CNN, using CNN-assisted expert review as the reference. When tested on manually labeled images, the CNN identified polyps with an area under the receiver operating characteristic curve (ROC-AUC) of 0.991 and an accuracy of 96.4%. In the analysis of colonoscopy videos in which 28 polyps were removed, 4 expert reviewers identified 8 additional polyps without CNN assistance that had not been removed and identified an additional 17 polyps with CNN assistance (45 in total). All polyps removed and identified by expert review were detected by the CNN. The CNN had a false-positive rate of 7%. In a set of 8641 colonoscopy images containing 4088 unique polyps the CNN identified polyps with a cross-validation accuracy of 96.4% and ROC-AUC value of 0.991. The CNN system can detect and localize polyps well within real-time constraints using an ordinary desktop machine with a contemporary graphics processing unit. This system could increase ADR and reduce interval colorectal cancers but requires validation in large multicenter trials. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  12. Functional evaluation of the endotics system, a new disposable self-propelled robotic colonoscope: in vitro tests and clinical trial.

    PubMed

    Cosentino, Felice; Tumino, Emanuele; Passoni, Giovanni Rubis; Morandi, Elisabetta; Capria, Alfonso

    2009-08-01

    Currently, the best method for CRC screening is colonoscopy, which ideally (where possible) is performed under partial or deep sedation. This study aims to evaluate the efficacy of the Endotics System, a new robotic device composed of a workstation and a disposable probe, in performing accurate and well-tolerated colonoscopies. This new system could also be considered a precursor of other innovating vectors for atraumatic locomotion through natural orifices such as the bowel. The flexible probe adapts its shape to the complex contours of the colon, thereby exerting low strenuous forces during its movement. These novel characteristics allow for a painless and safe colonoscopy, thus eliminating all major associated risks such as infection, cardiopulmonary complications and colon perforation. An experimental study was devised to investigate stress pattern differences between traditional and robotic colonoscopy, in which 40 enrolled patients underwent both robotic and standard colonoscopy within the same day. The stress pattern related to robotic colonoscopy was 90% lower than that of standard colonoscopy. Additionally, the robotic colonoscopy demonstrated a higher diagnostic accuracy, since, due to the lower insufflation rate, it was able to visualize small polyps and angiodysplasias not seen during the standard colonoscopy. All patients rated the robotic colonoscopy as virtually painless compared to the standard colonoscopy, ranking pain and discomfort as 0.9 and 1.1 respectively, on a scale of O to 10, versus 6.9 and 6.8 respectively for the standard device. The new Endotics System demonstrates efficacy in the diagnosis of colonic pathologies using a procedure nearly completely devoid of pain. Therefore, this system can also be looked upon as the first step toward developing and implementing colonoscopy with atraumatic locomotion through the bowel while maintaining a high level of diagnostic accuracy;

  13. How does genetic risk information for Lynch syndrome translate to risk management behaviours?

    PubMed

    Steel, Emma; Robbins, Andrew; Jenkins, Mark; Flander, Louisa; Gaff, Clara; Keogh, Louise

    2017-01-01

    There is limited research on why some individuals who have undergone predictive genetic testing for Lynch syndrome do not adhere to screening recommendations. This study aimed to explore qualitatively how Lynch syndrome non-carriers and carriers translate genetic risk information and advice to decisions about risk managment behaviours in the Australian healthcare system. Participants of the Australasian Colorectal Cancer Family Registry who had undergone predictive genetic testing for Lynch syndrome were interviewed on their risk management behaviours. Transcripts were analysed thematically using a comparative coding analysis. Thirty-three people were interviewed. Of the non-carriers ( n  = 16), 2 reported having apparently unnecessary colonoscopies, and 6 were unsure about what population-based colorectal cancer screening entails. Of the carriers ( n  = 17), 2 reported they had not had regular colonoscopies, and spoke about their discomfort with the screening process and a lack of faith in the procedure's ability to reduce their risk of developing colorectal cancer. Of the female carriers ( n  = 9), 2 could not recall being informed about the associated risk of gynaecological cancers. Non-carriers and female carriers of Lynch syndrome could benefit from further clarity and advice about appropriate risk management options. For those carriers who did not adhere to colonoscopy screening, a lack of faith in both genetic test results and screening were evident. It is essential that consistent advice is offered to both carriers and non-carriers of Lynch syndrome.

  14. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial.

    PubMed

    Horimatsu, Takahiro; Sano, Yasushi; Tanaka, Shinji; Kawamura, Takuji; Saito, Shoichi; Iwatate, Mineo; Oka, Shiro; Uno, Koji; Yoshimura, Kenichi; Ishikawa, Hideki; Muto, Manabu; Tajiri, Hisao

    2015-07-01

    Previous studies have yielded conflicting results on the colonic polyp detection rate with narrow-band imaging (NBI) compared with white-light imaging (WLI). We compared the mean number of colonic polyps detected per patient for NBI versus WLI using a next-generation NBI system (EVIS LUCERA ELITE; Olympus Medical Systems) used with standard-definition (SD) colonoscopy and wide-angle (WA) colonoscopy. this study is a 2 × 2 factorial, prospective, multicenter randomized controlled trial. this study was conducted at five academic centers in Japan. patients were allocated to one of four groups: (1) WLI with SD colonoscopy (H260AZI), (2) NBI with SD colonoscopy (H260AZI), (3) WLI with WA colonoscopy (CF-HQ290), and (4) NBI with WA colonoscopy (CF-HQ290). the mean numbers of polyps detected per patient were compared between the four groups: WLI with/without WA colonoscopy and NBI with/without WA colonoscopy. Of the 454 patients recruited, 431 patients were enrolled. The total numbers of polyps detected by WLI with SD, NBI with SD, WLI with WA, and NBI with WA were 164, 176, 188, and 241, respectively. The mean number of polyps detected per patient was significantly higher in the NBI group than in the WLI group (2.01 vs 1.56; P = 0.032). The rate was not higher in the WA group than in the SD group (1.97 vs 1.61; P = 0.089). Although WA colonoscopy did not improve the polyp detection, next-generation NBI colonoscopy represents a significant improvement in the detection of colonic polyps.

  15. Promoting colorectal cancer screening through group education in community-based settings.

    PubMed

    Crookes, Danielle M; Njoku, Ogo; Rodriguez, Maria Carina; Mendez, Elsa Iris; Jandorf, Lina

    2014-06-01

    National colonoscopy adherence rates near 65% and New York City (NYC) colonoscopy rates approach 69%. Despite an overall increase in national colorectal cancer (CRC) screening rates, rates of CRC screening among Blacks and Latinos are lower than non-Latino Whites. We developed two group level, culturally targeted educational programs about CRC for Blacks and Latinos. One hour programs included education about screening, peer testimony given by a colonoscopy-adherent person, and pre- and post-knowledge assessment. From 2010 to 2012, we conducted 66 education programs in NYC, reaching 1,065 participants, 62.7% of whom were 50 years of age or older identified as Black or Latino and provided information about colonoscopy history (N = 668). Colonoscopy adherence in the sample was 69.3%. There was a significant increase in mean knowledge score about CRC and CRC screening from pretest to posttest. Sixty-eight percent of attendees without prior colonoscopy reported intent to schedule a colonoscopy as a result of attending the program. Culturally targeted education programs with peer testimony are a valuable way to raise awareness about CRC and colonoscopy and can influence intent to screen among nonadherent persons. Additional research is needed to establish group level education as an effective means of promoting CRC screening.

  16. Cancer risk awareness and screening uptake in individuals at higher risk for colon cancer: a cross-sectional study.

    PubMed

    Salimzadeh, Hamideh; Bishehsari, Faraz; Delavari, Alireza; Barzin, Gilda; Amani, Mohammad; Majidi, Azam; Sadjadi, Alireza; Malekzadeh, Reza

    2016-12-20

    We aimed to measure cancer knowledge and feasibility of a screening colonoscopy among a cohort of individuals at higher risk of colon cancer. This study was conducted as part of an ongoing screening cohort, in which first degree relatives (FDRs) of patients with colon cancer are invited to participate in a free of charge screening colonoscopy. We enrolled 1017 FDRs in the study between 2013 and 2014 measuring their data on demographics, cancer knowledge and colonoscopy uptake. A p value of <0.05 was considered statistically significant. The relative's mean age was 48.7 years. Only about 28% of FDRs were aware of their increased risk for cancer, near 35.0% had ever heard about colonoscopy with 22% aware of the correct age to start screening. Comparing cancer knowledge of FDRs at high risk versus those at moderate risk, we recorded non-significant differences (p>0.05). Almost two-thirds of FDRs expressed willingness to undergo a colonoscopy and 49.2% completed the procedure, of which 12.8% had advanced neoplasm. Our data indicated that remarkable numbers of FDRs were not still informed of their cancer risk or never received a physician recommendation for screening. The desirable uptake at first invitation, which would be higher over successive invitations, supports the feasibility of a family-based recruitment approach for early screening. This has promising implications to introduce targeted screening colonoscopy into the healthcare system in Iran and other developing nations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Colonoscopy-based colorectal cancer modeling in mice with CRISPR-Cas9 genome editing and organoid transplantation.

    PubMed

    Roper, Jatin; Tammela, Tuomas; Akkad, Adam; Almeqdadi, Mohammad; Santos, Sebastian B; Jacks, Tyler; Yilmaz, Ömer H

    2018-02-01

    Most genetically engineered mouse models (GEMMs) of colorectal cancer are limited by tumor formation in the small intestine, a high tumor burden that limits metastasis, and the need to generate and cross mutant mice. Cell line or organoid transplantation models generally produce tumors in ectopic locations-such as the subcutaneous space, kidney capsule, or cecal wall-that do not reflect the native stromal environment of the colon mucosa. Here, we describe detailed protocols to rapidly and efficiently induce site-directed tumors in the distal colon of mice that are based on colonoscopy-guided mucosal injection. These techniques can be adapted to deliver viral vectors carrying Cre recombinase, CRISPR-Cas9 components, CRISPR-engineered mouse tumor organoids, or human cancer organoids to mice to model the adenoma-carcinoma-metastasis sequence of tumor progression. The colonoscopy injection procedure takes ∼15 min, including preparation. In our experience, anyone with reasonable hand-eye coordination can become proficient with mouse colonoscopy and mucosal injection with a few hours of practice. These approaches are ideal for a wide range of applications, including assessment of gene function in tumorigenesis, examination of tumor-stroma interactions, studies of cancer metastasis, and translational research with patient-derived cancers.

  18. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn's Disease.

    PubMed

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-04-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn's disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-value<0.05 was considered as statistically significant. RESULTS Of the 30 patients with active CD, 11(36.7%) were men and 19 (63.3%) were women with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease.

  19. Inter-Physician Variation in Follow-Up Colonoscopies after Screening Colonoscopy

    PubMed Central

    Stock, Christian; Hoffmeister, Michael; Birkner, Berndt; Brenner, Hermann

    2013-01-01

    Background and Aims Surveillance is an integral part of the colorectal cancer (CRC) screening process. We aimed to investigate inter-physician variation in follow-up procedures after screening colonoscopy in an opportunistic CRC screening program. Methods A historical cohort study in the German statutory health insurance system was conducted. 55,301 individuals who underwent screening colonoscopy in 2006 in Bavaria, Germany, and who were not diagnosed with CRC were included. Utilization of follow-up colonoscopies performed by the same physician (328 physicians overall) within 3 years was ascertained. Mixed effects logistic regression modelling was used to assess the effect of physicians and other potential predictors (screening result, age group, and sex) on re-utilization of colonoscopy. Physicians were grouped into quintiles according to individual effects estimated in a preliminary model. Predicted probabilities of follow-up colonoscopy by screening result and physician group were calculated. Results The observed rate of follow-up colonoscopy was 6.2% (95% confidence interval: 5.9-6.4%), 18.6% (17.8-19.4%), and 37.0% (35.5-38.4%) after negative colonoscopy, low-risk adenoma and high-risk adenoma detection, respectively. All considered predictors were statistically significantly associated with follow-up colonoscopy. The predicted probabilities of follow-up colonoscopy ranged from 1.7% (1.4-2.0%) to 11.0% (10.2-11.7%), from 7.3% (6.2-8.5%) to 35.1% (32.6-37.7%), and from 17.9% (15.5-20.6%) to 56.9% (53.5-60.3%) in the 1st quintile (lowest rates of follow-up) and 5th quintile (highest rates of follow-up) of physicians after negative colonoscopy, low-risk adenoma and high-risk adenoma detection, respectively. Conclusions This study suggests substantial inter-physician variation in follow-up habits after screening colonoscopy. Interventions, including organizational changes in CRC screening should be considered to reduce this variation. PMID:23874941

  20. AFRICAN-AMERICANS’ AND LATINOS’ PERCEPTIONS OF USING HYPNOSIS TO ALLEVIATE DISTRESS BEFORE A COLONOSCOPY

    PubMed Central

    Miller, Sarah J.; Schnur, Julie B.; Montgomery, Guy H.; Jandorf, Lina

    2013-01-01

    Although colorectal cancer (CRC) screenings can effectively detect and prevent cancer, a large portion of African-Americans and Latinos do not undergo regular colonoscopy screening. Research suggests that anticipatory distress can significantly hinder minorities’ adherence to colonoscopy recommendations. There is significant promise that hypnosis may effectively reduce such distress. The current study examined African-Americans’ and Latinos’ (n = 213) perceptions of using hypnosis prior to a colonoscopy. Overall, 69.9% of the sample expressed favourable perceptions of using pre-colonoscopy hypnosis, although there was notable variability. The results from this study can guide clinical decision making and inform future research efforts. PMID:26566440

  1. High-definition colonoscopy increases adenoma detection rate.

    PubMed

    Jrebi, Nezar Y; Hefty, Matthew; Jalouta, Tarek; Ogilvie, James; Davis, Alan T; Asgeirsson, Theodor; Luchtefeld, Martin

    2017-01-01

    The adenoma detection rate (ADR) is a quality indicator for colonoscopy. High-definition (HD) imaging has been reported to increase polyp detection rates. The primary objective of this study was to compare polyp detection rate (PDR) and adenoma detection rate (ADR) before and after the implementation of HD colonoscopy. A retrospective chart review was performed on patients aged 48-55 years old, who underwent first-time screening colonoscopy. The first group underwent standard-definition (SD) colonoscopy in the first 6 months of 2011. The second group underwent screening with HD colonoscopy during the first 6 months of 2012. We compared age, gender, PDR, ADR, and average sizes of adenomatous polyps between gastroenterologist and colorectal surgeon and among physicians themselves. Statistical analysis was performed with Fischer's exact test and Pearson Chi-square. A total of 1268 patients were involved in the study (634 in each group). PDR (35.6 vs. 48.2 %, p < 0.001) and ADR (22.2 vs. 30.4 %, p = 0.02) were higher in the HD group. The average size of an adenomatous polyp was the same in the two groups (0.58 vs. 0.57, p = 0.69). However, this difference was not seen among colorectal surgeons PDR (35.7 vs. 37 %, p = 0.789), ADR (22.9 vs. 24.5 % p = 0.513), but clearly seen among gastroenterologist, PDR (35.6 vs. 53.1 % p < 0.001) and ADR (21.9 vs. 32.9 % p < 0.001). When polyps were categorized into size groups, there was no difference in ADR between the two timeframes (<5 mm in size (41.5 vs. 35.4 %), 5-10 mm (49.3 vs. 60.1 %) and >10 mm (9.2 vs. 4.5 %), p = 0.07). Polyps were most commonly seen in the sigmoid colon (26.1 vs. 24.7 %). There was no difference in the rate of synchronous polyp detection between modalities (25.6 vs. 29 %, p = 0.51). Withdrawal time was the same in both procedure (9.2 vs. 8.5 min, p = 0.10). Screening colonoscopy with high-definition technology significantly improved both PDR and ADR. In addition, high-definition colonoscopy may be particularly useful and advantageous among less experienced endoscopists in various community settings. However, there needs to be application to specific patient populations in future studies to assess for any statistical differences between standard- and high-definition modalities to determine clinical utility.

  2. Decentralized colonoscopic surveillance with high patient compliance prevents hereditary and familial colorectal cancer.

    PubMed

    Sjöström, Olle; Lindholm, Lars; Tavelin, Björn; Melin, Beatrice

    2016-10-01

    Although colonoscopic surveillance is recommended both for individuals with known hereditary colorectal cancer (HCRC) syndromes and those with a more moderate familial colorectal cancer (FCRC) history, the evidence for the benefits of surveillance is limited and surveillance practices vary. This study evaluates the preventive effect for individuals with a family history of CRC of decentralized colonoscopic surveillance with the guidance of a cancer prevention clinic. We performed a population based prospective study of 261 patients with HCRC or FCRC, recorded in the colonoscopic surveillance registry at the Cancer genetics clinic, University Hospital of Umeå, Sweden. Colonoscopic surveillance was conducted every second (HCRC) or fifth (FCRC) year at local hospitals in Northern Sweden. Main outcome measures were findings of high-risk adenomas (HRA) or CRC, and patient compliance to surveillance. Estimations of the expected numbers of CRC without surveillance were made. During a total of 1256 person years of follow-up, one case of CRC was found. The expected numbers of cancers in the absence of surveillance was between 9.5 and 10.5, resulting in a standardized incidence ratio, observed versus expected cases of CRC, between 0.10 (CI 95 % 0.0012-0.5299) and 0.11 (CI 95 % 0.0014-0.5857). No CRC mortality was reported, but three patients needed surgical intervention. HRA were found in 5.9 % (14/237) of the initial and in 3.4 % (12/356) of the follow-up colonoscopies. Patient compliance to the surveillance program was 90 % as 597 of the planned 662 colonoscopies were performed. The study concludes that colonoscopic surveillance with high patient compliance to the program is effective in preventing CRC when using a decentralized method for colonoscopy surveillance with the guidance of a cancer prevention clinic.

  3. Colonoscopy video quality assessment using hidden Markov random fields

    NASA Astrophysics Data System (ADS)

    Park, Sun Young; Sargent, Dusty; Spofford, Inbar; Vosburgh, Kirby

    2011-03-01

    With colonoscopy becoming a common procedure for individuals aged 50 or more who are at risk of developing colorectal cancer (CRC), colon video data is being accumulated at an ever increasing rate. However, the clinically valuable information contained in these videos is not being maximally exploited to improve patient care and accelerate the development of new screening methods. One of the well-known difficulties in colonoscopy video analysis is the abundance of frames with no diagnostic information. Approximately 40% - 50% of the frames in a colonoscopy video are contaminated by noise, acquisition errors, glare, blur, and uneven illumination. Therefore, filtering out low quality frames containing no diagnostic information can significantly improve the efficiency of colonoscopy video analysis. To address this challenge, we present a quality assessment algorithm to detect and remove low quality, uninformative frames. The goal of our algorithm is to discard low quality frames while retaining all diagnostically relevant information. Our algorithm is based on a hidden Markov model (HMM) in combination with two measures of data quality to filter out uninformative frames. Furthermore, we present a two-level framework based on an embedded hidden Markov model (EHHM) to incorporate the proposed quality assessment algorithm into a complete, automated diagnostic image analysis system for colonoscopy video.

  4. A content-based image retrieval method for optical colonoscopy images based on image recognition techniques

    NASA Astrophysics Data System (ADS)

    Nosato, Hirokazu; Sakanashi, Hidenori; Takahashi, Eiichi; Murakawa, Masahiro

    2015-03-01

    This paper proposes a content-based image retrieval method for optical colonoscopy images that can find images similar to ones being diagnosed. Optical colonoscopy is a method of direct observation for colons and rectums to diagnose bowel diseases. It is the most common procedure for screening, surveillance and treatment. However, diagnostic accuracy for intractable inflammatory bowel diseases, such as ulcerative colitis (UC), is highly dependent on the experience and knowledge of the medical doctor, because there is considerable variety in the appearances of colonic mucosa within inflammations with UC. In order to solve this issue, this paper proposes a content-based image retrieval method based on image recognition techniques. The proposed retrieval method can find similar images from a database of images diagnosed as UC, and can potentially furnish the medical records associated with the retrieved images to assist the UC diagnosis. Within the proposed method, color histogram features and higher order local auto-correlation (HLAC) features are adopted to represent the color information and geometrical information of optical colonoscopy images, respectively. Moreover, considering various characteristics of UC colonoscopy images, such as vascular patterns and the roughness of the colonic mucosa, we also propose an image enhancement method to highlight the appearances of colonic mucosa in UC. In an experiment using 161 UC images from 32 patients, we demonstrate that our method improves the accuracy of retrieving similar UC images.

  5. Modeling Individual Patient Preferences for Colorectal Cancer Screening Based on Their Tolerance for Complications Risk.

    PubMed

    Taksler, Glen B; Perzynski, Adam T; Kattan, Michael W

    2017-04-01

    Recommendations for colorectal cancer screening encourage patients to choose among various screening methods based on individual preferences for benefits, risks, screening frequency, and discomfort. We devised a model to illustrate how individuals with varying tolerance for screening complications risk might decide on their preferred screening strategy. We developed a discrete-time Markov mathematical model that allowed hypothetical individuals to maximize expected lifetime utility by selecting screening method, start age, stop age, and frequency. Individuals could choose from stool-based testing every 1 to 3 years, flexible sigmoidoscopy every 1 to 20 years with annual stool-based testing, colonoscopy every 1 to 20 years, or no screening. We compared the life expectancy gained from the chosen strategy with the life expectancy available from a benchmark strategy of decennial colonoscopy. For an individual at average risk of colorectal cancer who was risk neutral with respect to screening complications (and therefore was willing to undergo screening if it would actuarially increase life expectancy), the model predicted that he or she would choose colonoscopy every 10 years, from age 53 to 73 years, consistent with national guidelines. For a similar individual who was moderately averse to screening complications risk (and therefore required a greater increase in life expectancy to accept potential risks of colonoscopy), the model predicted that he or she would prefer flexible sigmoidoscopy every 12 years with annual stool-based testing, with 93% of the life expectancy benefit of decennial colonoscopy. For an individual with higher risk aversion, the model predicted that he or she would prefer 2 lifetime flexible sigmoidoscopies, 20 years apart, with 70% of the life expectancy benefit of decennial colonoscopy. Mathematical models may formalize how individuals with different risk attitudes choose between various guideline-recommended colorectal cancer screening strategies.

  6. Managed care and the diffusion of endoscopy in fee-for-service Medicare.

    PubMed

    Mobley, Lee Rivers; Subramanian, Sujha; Koschinsky, Julia; Frech, H E; Trantham, Laurel Clayton; Anselin, Luc

    2011-12-01

    To determine whether Medicare managed care penetration impacted the diffusion of endoscopy services (sigmoidoscopy, colonoscopy) among the fee-for-service (FFS) Medicare population during 2001-2006. We model utilization rates for colonoscopy or sigmoidoscopy as impacted by both market supply and demand factors. We use spatial regression to perform ecological analysis of county-area utilization rates over two time intervals (2001-2003, 2004-2006) following Medicare benefits expansion in 2001 to cover colonoscopy for persons of average risk. We examine each technology in separate cross-sectional regressions estimated over early and later periods to assess differential effects on diffusion over time. We discuss selection factors in managed care markets and how failure to control perfectly for market selection might impact our managed care spillover estimates. Areas with worse socioeconomic conditions have lower utilization rates, especially for colonoscopy. Holding constant statistically the socioeconomic factors, we find that managed care spillover effects onto FFS Medicare utilization rates are negative for colonoscopy and positive for sigmoidoscopy. The spatial lag estimates are conservative and interpreted as a lower bound on true effects. Our findings suggest that managed care presence fostered persistence of the older technology during a time when it was rapidly being replaced by the newer technology. © Health Research and Educational Trust.

  7. The Polyp Manager: a new tool for optimal polyp documentation during colonoscopy. A pilot study.

    PubMed Central

    van de Meeberg, Maartje M.; Ouwendijk, Rob J. Th.; ter Borg, Pieter C. J.; van den Hazel, Sven J.; van de Meeberg, Paul C.

    2016-01-01

    Background and study aims: Conventional reporting of polyps is often incomplete. We tested the Polyp Manager (PM), a new software application permitting the endoscopist to document polyps in real time during colonoscopy. We studied completeness of polyp descriptions, user-friendliness and the potential time benefit. Patients and methods: In two Dutch hospitals colonoscopies were performed with PM (as a touchscreen endoscopist-operated device or nurse-operated desktop application). Completeness of polyp descriptions was compared to a historical group with conventional reporting (CRH). Prospectively, we compared user-friendliness (VAS-scores) and time benefit of the endoscopist-operated PM to conventional reporting (CR) in one hospital. Duration of colonoscopy and time needed to report polyps and provide a pathology request were measured. Provided that using PM does not prolong colonoscopy, the sum of the latter two was considered as a potential time-benefit if the PM were fully integrated into a digital reporting system. Results: A total of 144 regular colonoscopies were included in the study. Both groups were comparable with regard to patient characteristics, duration of colonoscopy and number of polyps. Using the PM did reduce incomplete documentation of the following items in CRH-reports: location (96 % vs 82 %, P = 0.01), size (95 % vs 89 %, P = 0.03), aspect (71 % vs 36 %, P < 0.001) and completeness of removal (61 % vs 37 %, P < 0.001). In the prospective study 23 PM-colonoscopies where compared to 28 CR-colonoscopies. VAS-scores were significantly higher in the endoscopist-operated PM group. Time to report was 01:27 ± 01:43 minutes (median + interquartile range) in the entire group (PM as CR), reflecting potential time benefit per colonoscopy. Conclusions: The PM is a user-friendly tool that seems to improve completeness of polyp reporting. Once integrated with digital reporting systems, it is probably time saving as well. PMID:27227117

  8. Association Between Socioeconomic Status and Participation in Colonoscopy Screening Program in First Degree Relatives of Colorectal Cancer Patients.

    PubMed

    Chouhdari, Arezoo; Yavari, Parvin; Pourhoseingholi, Mohammad Amin; Sohrabi, Mohammad-Reza

    2016-04-01

    Approximately 15% to 25% of colorectal cancer (CRC) cases have positive family history for disease. Colonoscopy screening test is the best way for prevention and early diagnosis. Studies have found that first degree relatives (FDRs) with low socioeconomic status are less likely to participate in colonoscopy screening program. The aim of this study is to determine the association between socioeconomic status and participation in colonoscopy screening program in FDRs. This descriptive cross-sectional, study has been conducted on 200 FDRs who were consulted for undergoing colonoscopy screening program between 2007 and 2013 in research institute for gastroenterology and liver disease of Shahid Beheshti University of Medical Sciences, Tehran, Iran. They were interviewed via phone by a valid questionnaire about socioeconomic status. For data analysis, chi-square, exact fisher and multiple logistic regression were executed by SPSS 19. The results indicated 58.5% participants underwent colonoscopy screening test at least once to the time of the interview. There was not an association between participation in colonoscopy screening program and socioeconomic status to the time of the interview in binomial analysis. But statistical significance between intention to participate and educational and income level were found. We found, in logistic regression analysis, that high educational level (Diploma and University degree in this survey) was a predictor to participate in colonoscopy screening program in FDRs. According to this survey low socioeconomic status is an important factor to hinder participation of FDRs in colonoscopy screening program. Therefore, planned interventions for elevation knowledge and attitude in FDRs with low educational level are necessary. Also, reducing colonoscopy test costs should be a major priority for policy makers.

  9. Efficacy of a Telehealth Intervention on Colonoscopy Uptake When Cost Is a Barrier: The Family CARE Cluster Randomized Controlled Trial.

    PubMed

    Steffen, Laurie E; Boucher, Kenneth M; Damron, Barbara H; Pappas, Lisa M; Walters, Scott T; Flores, Kristina G; Boonyasiriwat, Watcharaporn; Vernon, Sally W; Stroup, Antoinette M; Schwartz, Marc D; Edwards, Sandra L; Kohlmann, Wendy K; Lowery, Jan T; Wiggins, Charles L; Hill, Deirdre A; Higginbotham, John C; Burt, Randall; Simmons, Rebecca G; Kinney, Anita Y

    2015-09-01

    We tested the efficacy of a remote tailored intervention Tele-Cancer Risk Assessment and Evaluation (TeleCARE) compared with a mailed educational brochure for improving colonoscopy uptake among at-risk relatives of colorectal cancer patients and examined subgroup differences based on participant reported cost barriers. Family members of colorectal cancer patients who were not up-to-date with colonoscopy were randomly assigned as family units to TeleCARE (N = 232) or an educational brochure (N = 249). At the 9-month follow-up, a cost resource letter listing resources for free or reduced-cost colonoscopy was mailed to participants who had reported cost barriers and remained nonadherent. Rates of medically verified colonoscopy at the 15-month follow-up were compared on the basis of group assignment and within group stratification by cost barriers. In intent-to-treat analysis, 42.7% of participants in TeleCARE and 24.1% of participants in the educational brochure group had a medically verified colonoscopy [OR, 2.37; 95% confidence interval (CI) 1.59-3.52]. Cost was identified as a barrier in both groups (TeleCARE = 62.5%; educational brochure = 57.0%). When cost was not a barrier, the TeleCARE group was almost four times as likely as the comparison to have a colonoscopy (OR, 3.66; 95% CI, 1.85-7.24). The intervention was efficacious among those who reported cost barriers; the TeleCARE group was nearly twice as likely to have a colonoscopy (OR, 1.99; 95% CI, 1.12-3.52). TeleCARE increased colonoscopy regardless of cost barriers. Remote interventions may bolster screening colonoscopy regardless of cost barriers and be more efficacious when cost barriers are absent. ©2015 American Association for Cancer Research.

  10. The factors associated with negative colonoscopy in screening subjects with positive immunochemical stool occult blood test outcomes.

    PubMed

    Ting, Po-Hsiang; Lin, Xi-Hsuan; Jiang, Jeng-Kai; Luo, Jiing-Chyuan; Chen, Ping-Hsien; Wang, Yen-Po; Hsin, I-Fang; Perng, Chin Lin; Hou, Ming-Chih; Lee, Fa-Yauh

    2018-05-16

    The immunochemical fecal occult blood test (iFOBT) is an alternative method to colonoscopy that can be used for colorectal cancer (CRC) screening. If the iFOBT result is positive, a colonoscopy is recommended. In this retrospective study, we identify factors associated with negative colonoscopy and positive iFOBT results obtained during CRC screening. We collected data for subjects who received a colonoscopy at Taipei Veterans General Hospital after receiving a positive iFOBT result during CRC screening from January 2015 to December 2015. Subjects' baseline data, medications, and co-morbidities as well as colonoscopy and histological findings were recorded. A negative colonoscopy result was defined as no detection of any colorectal neoplasia including non-advanced adenoma, advanced adenoma, and adenocarciona. Multivariate logistic regression analysis was conducted to identify the associated factors in screening subjects with positive iFOBT but negative colonoscopy results. 559 (46.3%) out of 1207 eligible study subjects received a colonoscopy with a negative result. Multivariate logistic regression analysis revealed that the use of antiplatelets [odds ratio (OR) = 0.654; 95% confidence interval (CI), 0.434-0.986], occurrence of hemorrhoid (OR = 0.595; 95% CI, 0.460-0.768), and the existence of colitis/ulcer (OR = 0.358; 95% CI, 0.162-0.789) were independent factors associated with negative colonoscopy but positive iFOBT results during CRC screening. The colon clean level, underlying diseases of gastrointestinal bleeding tendency (e.g., chronic kidney disease, cirrhosis), and the use of anticoagulant or nonsteroidal anti-inflammatory agents were not associated with negative colonoscopy and positive iFOBT results. The use of antiplatelet agents and the presence of hemorrhoids and colitis/ulcers were factors associated with negative colonoscopy and positive iFOBT results. Copyright © 2018. Published by Elsevier Taiwan LLC.

  11. Fecal Microbiota Characteristics of Patients with Colorectal Adenoma Detected by Screening: A Population-based Study

    PubMed Central

    Goedert, James J.; Gong, Yangming; Hua, Xing; Zhong, Huanzi; He, Yimin; Peng, Peng; Yu, Guoqin; Wang, Wenjing; Ravel, Jacques; Shi, Jianxin; Zheng, Ying

    2015-01-01

    Background Screening for colorectal cancer (CRC) and precancerous colorectal adenoma (CRA) can detect curable disease. However, participation in colonoscopy and sensitivity of fecal heme for CRA are low. Methods Microbiota metrics were determined by Illumina sequencing of 16S rRNA genes amplified from DNA extracted from feces self-collected in RNAlater. Among fecal immunochemical test-positive (FIT +) participants, colonoscopically-defined normal versus CRA patients were compared by regression, permutation, and random forest plus leave-one-out methods. Findings Of 95 FIT + participants, 61 had successful fecal microbiota profiling and colonoscopy, identifying 24 completely normal patients, 20 CRA patients, 2 CRC patients, and 15 with other conditions. Phylum-level fecal community composition differed significantly between CRA and normal patients (permutation P = 0.02). Rank phylum-level abundance distinguished CRA from normal patients (area under the curve = 0.767, permutation P = 0.006). CRA prevalence was 59% in phylum-level cluster B versus 20% in cluster A (exact P = 0.01). Most of the difference reflected 3-fold higher median relative abundance of Proteobacteria taxa (Wilcoxon signed-rank P = 0.03, positive predictive value = 67%). Antibiotic exposure and other potential confounders did not affect the associations. Interpretation If confirmed in larger, more diverse populations, fecal microbiota analysis might be employed to improve screening for CRA and ultimately to reduce mortality from CRC. PMID:26288821

  12. Sensitivity of 2-[18F]fluoro-2-deoxyglucose positron emission tomography for advanced colorectal neoplasms: a large-scale analysis of 7505 asymptomatic screening individuals.

    PubMed

    Sekiguchi, Masau; Kakugawa, Yasuo; Terauchi, Takashi; Matsumoto, Minori; Saito, Hiroshi; Muramatsu, Yukio; Saito, Yutaka; Matsuda, Takahisa

    2016-12-01

    The sensitivity of 2-[ 18 F]fluoro-2-deoxyglucose positron emission tomography (FDG-PET) for advanced colorectal neoplasms among healthy subjects is not yet fully understood. The present study aimed to clarify the sensitivity by analyzing large-scale data from an asymptomatic screening population. A total of 7505 asymptomatic screenees who underwent both FDG-PET and colonoscopy at our Cancer Screening Division between February 2004 and March 2013 were analyzed. FDG-PET and colonoscopy were performed on consecutive days, and each examination was interpreted in a blinded fashion. The results of the two examinations were compared for each of the divided six colonic segments, with those from colonoscopy being set as the reference. The relationships between the sensitivity of FDG-PET and clinicopathological features of advanced neoplasms were also evaluated. Two hundred ninety-one advanced neoplasms, including 24 invasive cancers, were detected in 262 individuals. Thirteen advanced neoplasms (advanced adenomas) were excluded from the analysis because of the coexistence of lesions in the same colonic segment. The sensitivity, specificity, and positive and negative predictive values of FDG-PET for advanced neoplasms were 16.9 % [95 % confidence interval (CI) 12.7-21.8 %], 99.3 % (95 % CI 99.2-99.4 %), 13.5 % (95 % CI 10.1-17.6 %), and 99.4 % (95 % CI 99.3-99.5 %), respectively. The sensitivity was lower for lesions with less advanced histological grade, of smaller size, and flat-type morphology, and for those located in the proximal part of the colon. FDG-PET is believed to be difficult to use as a primary screening tool in population-based colorectal cancer screening because of its low sensitivity for advanced neoplasms. Even when it is used in opportunistic cancer screening, the limit of its sensitivity should be considered.

  13. Feasibility of a colon capsule overnight procedure followed by colonoscopy.

    PubMed

    Brechmann, T; Schmiegel, W; Klute, L; Rösch, T; Pox, C

    2016-02-01

    Due to limited acceptance of colonoscopy as diagnostic and screening test alternatives are warranted. Colon capsule endoscopy (CCE) has been shown to be a possible filter test, but because of logistical issues a second bowel preparation is usually required, if consecutive colonoscopy is needed. We therefore evaluated the feasibility of a single bowel preparation for both overnight CCE and (therapeutical) colonoscopy thereafter. Patients from two university hospitals referred to undergo colonoscopy were prospectively included in a dual centre feasibility study. A polyethylene glycol (PEG) based bowel preparation-schedule with ingestion of a colon capsule endoscopy (CCE) at 10pm and subsequent colonoscopy at about 12am on the next day was investigated. The first generation PillCam colon capsule was used with 4 different preparation protocols containing several prokinetics in different compositions (i. e. metoclopramide, erythromycin, sennosoides). The main endpoint was the proportion of patients who completed both CCE and colonoscopy; secondary endpoints were capsule transit times, amount of colon seen on CCE, bowel cleanliness, sensitivity and specifity of CCE and patients' acceptance. 50 patients between 18 and 75 years were included. The sequence of overnight colon capsule endoscopy and colonoscopy was successfully completed in all but one (one refused colonoscopy). The capsule was excreted during recording time in 86 % of examinations, visualization of the complete colon was possible in 60 %, but adequate colon preparation was achieved in only 45 % irrespective of the regimen used. The preparation regimen consisting of a PEG-solution, erythromycin as prokinetic drug followed by PEG-solution as boost showed the largest proportion of adequate preparations. Overall sensitivity and specificity of CCE for polyps of any size were 65 % and 76 %, respectively. 26 of 30 patients (86.7 %) returned the subjective assessment questionnaire. 23 patients (88 %) reported mild to no discomfort or embarrassment during CCE, whereas 15 patients (58 %) did during the preparation procedure. Drinking the purgative solution was the most inconvenient step in 84 % of cases, drinking the boosts during CCE the second inconvenient step (60 %). Overnight CCE-procedure followed by direct capsule-reading is feasible and safe and might avoid repetitive bowel preparation for subsequent colonoscopy. The bowel preparation needs to be improved. © Georg Thieme Verlag KG Stuttgart · New York.

  14. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    PubMed

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  15. Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality: an observational prospective study.

    PubMed

    Seo, Eun Hee; Kim, Tae Oh; Park, Min Jae; Joo, Hee Rin; Heo, Nae Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo

    2012-03-01

    Several factors influence bowel preparation quality. Recent studies have indicated that the time interval between bowel preparation and the start of colonoscopy is also important in determining bowel preparation quality. To evaluate the influence of the preparation-to-colonoscopy (PC) interval (the interval of time between the last polyethylene glycol dose ingestion and the start of the colonoscopy) on bowel preparation quality in the split-dose method for colonoscopy. Prospective observational study. University medical center. A total of 366 consecutive outpatients undergoing colonoscopy. Split-dose bowel preparation and colonoscopy. The quality of bowel preparation was assessed by using the Ottawa Bowel Preparation Scale according to the PC interval, and other factors that might influence bowel preparation quality were analyzed. Colonoscopies with a PC interval of 3 to 5 hours had the best bowel preparation quality score in the whole, right, mid, and rectosigmoid colon according to the Ottawa Bowel Preparation Scale. In multivariate analysis, the PC interval (odds ratio [OR] 1.85; 95% CI, 1.18-2.86), the amount of PEG ingested (OR 4.34; 95% CI, 1.08-16.66), and compliance with diet instructions (OR 2.22l 95% CI, 1.33-3.70) were significant contributors to satisfactory bowel preparation. Nonrandomized controlled, single-center trial. The optimal time interval between the last dose of the agent and the start of colonoscopy is one of the important factors to determine satisfactory bowel preparation quality in split-dose polyethylene glycol bowel preparation. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. The utility of Google Trends data to examine interest in cancer screening

    PubMed Central

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-01-01

    Objectives We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. Setting State-level data across the USA. Participants Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). Primary and secondary outcome measures (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Results Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Conclusions Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. PMID:26056120

  17. Comparison between different colon cleansing products for screening colonoscopy. A noninferiority trial in population-based screening programs in Italy.

    PubMed

    Zorzi, Manuel; Valiante, Flavio; Germanà, Bastianello; Baldassarre, Gianluca; Coria, Bartolomea; Rinaldi, Michela; Heras Salvat, Helena; Carta, Alessandra; Bortoluzzi, Francesco; Cervellin, Erica; Polo, Maria Luisa; Bulighin, Gianmarco; Azzurro, Maurizio; Di Piramo, Daniele; Turrin, Anna; Monica, Fabio

    2016-03-01

    The high volume and poor palatability of 4 L of polyethylene glycol (PEG)-based bowel cleansing preparation required before a colonoscopy represent a major obstacle for patients. The aim of this study was to compare two low volume PEG-based preparations with standard 4 L PEG in individuals with a positive fecal immunochemical test (FIT) within organized screening programs in Italy. A total of 3660 patients with a positive FIT result were randomized to receive, in a split-dose regimen, 4 L PEG or 2 L PEG plus ascorbate (PEG-A) or 2 L PEG with citrate and simethicone plus bisacodyl (PEG-CS). The noninferiority of the low volume preparations vs. 4 L PEG was tested through the difference in proportions of adequate cleansing. A total of 2802 patients were included in the study. Adequate bowel cleansing was achieved in 868 of 926 cases (93.7 %) in the 4 L PEG group, in 872 out of 911 cases in the PEG-A group (95.7 %, difference in proportions  + 1.9 %, 95 % confidence interval [CI]  - 0.1 to 3.9), and in 862 out of 921 cases in the PEG-CS group (93.6 %, difference in proportions  - 0.2 %, 95 %CI  - 2.4 to 2.0). Bowel cleansing was adequate in 95.5 % of cases when the preparation-to-colonoscopy interval was between 120 and 239 minutes, whereas it dropped to 83.3 % with longer intervals. Better cleansing was observed in patients with regular bowel movements (95.6 %) compared with those with diarrhea (92.4 %) or constipation (90.8 %). Low volume PEG-based preparations administered in a split-dose regimen guarantee noninferior bowel cleansing compared with 4 L PEG. Constipated patients require a personalized preparation. EudraCT 2012 - 003958 - 82. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Development of the Parkland-UT Southwestern Colonoscopy Reporting System (CoRS) for evidence-based colon cancer surveillance recommendations

    PubMed Central

    Gupta, Samir; Halm, Ethan A; Wright, Shaun; McCallister, Katharine; Bishop, Wendy; Santini, Noel; Mayorga, Christian; Agrawal, Deepak; Moran, Brett; Sanders, Joanne M; Singal, Amit G

    2016-01-01

    Objective Through colonoscopy, polyps can be identified and removed to reduce colorectal cancer incidence and mortality. Appropriate use of surveillance colonoscopy, post polypectomy, is a focus of healthcare reform. Materials and Methods The authors developed and implemented the first electronic medical record–based colonoscopy reporting system (CoRS) that matches endoscopic findings with guideline-consistent surveillance recommendations and generates tailored results and recommendation letters for patients and providers. Results In its first year, CoRS was used in 98.6% of indicated cases. Via a survey, colonoscopists agreed/strongly agreed it is easy to use (83%), provides guideline-based recommendations (89%), improves quality of Spanish letters (94%), they would recommend it for other institutions (78%), and it made their work easier (61%), and led to improved practice (56%). Discussion CoRS’ widespread adoption and acceptance likely resulted from stakeholder engagement throughout the development and implementation process. Conclusion CoRS is well-accepted by clinicians and provides guideline-based recommendations and results communications to patients and providers. PMID:26254481

  19. A multicenter, randomized controlled trial comparing the identification rate of stigmata of recent hemorrhage and rebleeding rate between early and elective colonoscopy in outpatient-onset acute lower gastrointestinal bleeding: study protocol for a randomized controlled trial.

    PubMed

    Niikura, Ryota; Nagata, Naoyoshi; Yamada, Atsuo; Doyama, Hisashi; Shiratori, Yasutoshi; Nishida, Tsutomu; Kiyotoki, Shu; Yada, Tomoyuki; Fujita, Tomoki; Sumiyoshi, Tetsuya; Hasatani, Kenkei; Mikami, Tatsuya; Honda, Tetsuro; Mabe, Katsuhiro; Hara, Kazuo; Yamamoto, Katsumi; Takeda, Mariko; Takata, Munenori; Tanaka, Mototsugu; Shinozaki, Tomohiro; Fujishiro, Mitsuhiro; Koike, Kazuhiko

    2018-04-03

    The clinical benefit of early colonoscopy within 24 h of arrival in patients with severe acute lower gastrointestinal bleeding (ALGIB) remains controversial. This trial will compare early colonoscopy (performed within 24 h) versus elective colonoscopy (performed between 24 and 96 h) to examine the identification rate of stigmata of recent hemorrhage (SRH) in ALGIB patients. We hypothesize that, compared with elective colonoscopy, early colonoscopy increases the identification of SRH and subsequently improves clinical outcomes. This trial is an investigator-initiated, multicenter, randomized, open-label, parallel-group trial examining the superiority of early colonoscopy over elective colonoscopy (standard therapy) in ALGIB patients. The primary outcome measure is the identification of SRH. Secondary outcomes include 30-day rebleeding, success of endoscopic treatment, need for additional endoscopic examination, need for interventional radiology, need for surgery, need for transfusion during hospitalization, length of stay, 30-day thrombotic events, 30-day mortality, preparation-related adverse events, and colonoscopy-related adverse events. The sample size will enable detection of a 9% SRH rate in elective colonoscopy patients and a SRH rate of ≥ 26% in early colonoscopy patients with a risk of type I error of 5% and a power of 80%. This trial will provide high-quality data on the benefits and risks of early colonoscopy in ALGIB patients. UMIN-CTR Identifier, UMIN000021129 . Registered on 21 February 2016; ClinicalTrials.gov Identifier, NCT03098173 . Registered on 24 March 2017.

  20. The accuracy of colonoscopic localisation of colorectal tumours: a prospective, multi-centred observational study.

    PubMed

    Johnstone, M S; Moug, S J

    2014-05-01

    Colonoscopy is essential for accurate pre-operative colorectal tumour localisation, but its accuracy for localisation remains undetermined due to limitations of previous work. This study aimed to establish the accuracy of colonoscopic localisation and to determine how frequently inaccuracy results in altered surgical management. A prospective, multi-centred, powered observational study recruited 79 patients with colorectal tumours that underwent curative surgical resection. Patient and colonoscopic factors were recorded. Pre-operative colonoscopic and radiological lesion localisations were compared to intra-operative localisation using pre-defined anatomical bowel segments to determine accuracy, with changes in planned surgical management documented. Colonoscopy accurately located the colorectal tumour in 64/79 patients (81%). Five out of 15 inaccurately located patients required on-table alteration in planned surgical management. Pre-operative imaging was unable to visualise the primary tumour in 23.1% of cases, a finding that was more prevalent amongst bowel screener patients compared to symptomatic patients (45.8% vs. 13%; p = 0.003). Colonoscopic lesion localisation is inaccurate in 19.0% of cases and occurred throughout the colon with a change in on-table surgical management in 6.3%. With CT unable to visualise lesions in just under a quarter of cases, particularly in the screening population, preoperative localisation is heavily reliant on colonoscopy.

  1. Surveillance colonoscopy after endoscopic treatment for colorectal neoplasia: From the standpoint of the Asia-Pacific region.

    PubMed

    Matsuda, Takahisa; Chiu, Han-Mo; Sano, Yasushi; Fujii, Takahiro; Ono, Akiko; Saito, Yutaka

    2016-04-01

    Colonoscopy is considered the gold standard to detect and remove colorectal neoplasia. The efficacy of colonoscopy with polypectomy to reduce colorectal cancer incidence and mortality has been demonstrated. Recently, post-polypectomy surveillance colonoscopy has become a necessary intervention in daily practice not only in Western countries but also in the Asia-Pacific region. Therefore, it is crucial to establish new clinical practice guidelines to reduce the number of unnecessary surveillance colonoscopies in order to create space for screening colonoscopy. The Asia-Pacific Consensus group recommended that surveillance colonoscopy interval should be tailored according to risk level of index colonoscopy. However, precise guidelines on interval of surveillance cannot be given because of a lack of prospective data. According to Korean and Australian guidelines, surveillance intervals after index colonoscopy of 5 years for low-risk subjects and 3 years for high-risk subjects are recommended in Asia-Pacific regions at present. Prospective data including long-term outcomes from the Japan Polyp Study, which is a multicenter randomized control trial, would be useful to establish the Asia-Pacific consensus in the near future. © 2016 Japan Gastroenterological Endoscopy Society.

  2. User's perspectives of barriers and facilitators to implementing quality colonoscopy services in Canada: a study protocol.

    PubMed

    Jobin, Gilles; Gagnon, Marie Pierre; Candas, Bernard; Dubé, Catherine; Ben Abdeljelil, Anis; Grenier, Sonya

    2010-11-02

    Colorectal cancer (CRC) represents a serious and growing health problem in Canada. Colonoscopy is used for screening and diagnosis of symptomatic or high CRC risk individuals. Although a number of countries are now implementing quality colonoscopy services, knowledge synthesis of barriers and facilitators perceived by healthcare professionals and patients during implementation has not been carried out. In addition, the perspectives of various stakeholders towards the implementation of quality colonoscopy services and the need of an efficient organisation of such services have been reported in the literature but have not been synthesised yet. The present study aims to produce a comprehensive synthesis of actual knowledge on the barriers and facilitators perceived by all stakeholders to the implementation of quality colonoscopy services in Canada. First, we will conduct a comprehensive review of the scientific literature and other published documentation on the barriers and facilitators to implementing quality colonoscopy services. Standardised literature searches and data extraction methods will be used. The quality of the studies and their relevance to informing decisions on colonoscopy services implementation will be assessed. For each group of users identified, barriers and facilitators will be categorised and compiled using narrative synthesis and meta-analytical techniques. The principle factors identified for each group of users will then be validated for its applicability to various Canadian contexts using the Delphi study method. Following this study, a set of strategies will be identified to inform decision makers involved in the implementation of quality colonoscopy services across Canadian jurisdictions. This study will be the first to systematically summarise the barriers and facilitators to implementation of quality colonoscopy services perceived by different groups and to consider the local contexts in order to ensure the applicability of this knowledge to the particular realities of various Canadian jurisdictions. Linkages with strategic partners and decision makers in the realisation of this project will favour the utilisation of its results to support strategies for implementing quality colonoscopy services and CRC screening programs in the Canadian health system.

  3. Does Urgent Colonoscopy Improve Outcomes in the Management of Lower Gastrointestinal Bleeding?

    PubMed

    Seth, Ankur; Khan, Muhammad Ali; Nollan, Richard; Gupta, Deepansh; Kamal, Sehrish; Singh, Utkarsh; Kamal, Faisal; Howden, Colin W

    2017-03-01

    Colonoscopy continues to be an essential diagnostic and therapeutic tool in the management of lower gastrointestinal bleeding (LGIB). Studies that have evaluated the role of urgent colonoscopy for treating LGIB have reached conflicting conclusions. We conducted a systematic review and meta-analysis to evaluate the role of urgent colonoscopy in several outcomes in patients with LGIB. We searched Medline, Embase, Scopus and Cochrane databases from inception to July 10, 2016 for comparative studies evaluating the role of urgent versus elective colonoscopy in the management of LGIB. We evaluated mortality, rate of rebleeding, length of stay in hospital, identification of bleeding source, stigmata of recent hemorrhage and need for surgery. Pooled odds ratios (OR) were calculated for dichotomous variables whereas standard mean differences were calculated for continuous variables. We assessed quality using the Cochrane tool and Newcastle Ottawa Scale for randomized controlled trials and observational studies, respectively. We used the GRADE framework to interpret our findings. A total of 6 studies (2 randomized controlled trials and 4 observational studies) with 23,419 patients (9,498 urgent colonoscopy and 13,921 elective colonoscopy) were included in this meta-analysis. Pooled ORs with 95% CI for mortality, rebleeding and identification of bleeding source were 0.84 (0.46-1.53), 1.18 (0.64-2.16) and 1.49 (0.86-2.59), respectively. Stigmata of recent hemorrhage were more readily identified with urgent colonoscopy OR 2.85 (1.90-4.28). There were no differences in requirement for surgery, length of hospital stay or rate of endoscopic intervention. However, these effect sizes were limited by considerable heterogeneity, which was probably due to studies being conducted in different countries having different criteria for discharge and on variations in the type of endoscopic therapy for stigmata of recent hemorrhage. In conclusion, among patients with acute LGIB, there is no evidence that urgent colonoscopy reduces mortality, rebleeding or requirement for surgery or that it improves the rate of identification of the bleeding source. However, urgent colonoscopy does increase the rate of detection of stigmata of recent hemorrhage. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  4. A randomized, controlled trial of oral sulfate solution plus polyethylene glycol as a bowel preparation for colonoscopy.

    PubMed

    Rex, Douglas K; McGowan, John; Cleveland, Mark vB; Di Palma, Jack A

    2014-09-01

    No bowel preparation for colonoscopy is optimal with regard to efficacy, safety, and tolerability. New options for bowel preparation are needed. To compare a new hybrid preparation consisting of a reduced dose of oral sulfate solution (OSS) plus 2 L of sulfate-free electrolyte lavage solution (SF-ELS) with 2 low-volume preparations based on polyethylene glycol electrolyte lavage solution (PEG-ELS). Two randomized, controlled trials. Twenty-four U.S. centers. A total of 737 outpatients undergoing colonoscopy. In study 1, OSS plus SF-ELS was given as a split dose, and in study 2, OSS plus SF-ELS was given in its entirety the evening before colonoscopy. In study 1, the active control was 2 L of PEG-ELS plus ascorbic acid (PEG-EA) given as a split dose. In study 2, the control was 10 mg of bisacodyl plus 2 L of SF-ELS taken the evening before colonoscopy. Rates of successful (good or excellent) bowel preparation. In study 1, the rates of successful (excellent or good) preparation with OSS plus SF-ELS and PEG-EA were identical at 93.5% for split-dose preparation. OSS plus SF-ELS was noninferior to PEG-EA (P < .001). In study 2, OSS plus SF-ELS resulted in successful preparation in 89.8% of patients compared with 83.5% with bisacodyl plus SF-ELS in a same-day preparation regimen. OSS plus SF-ELS was noninferior to bisacodyl plus SF-ELS (P <.001). In study 1, vomiting was more frequent with OSS plus SF-ELS (13.5% vs 6.7%; P = .042), and bloating was rated worse with PEG-EA (P = .025). In study 2, overall discomfort was rated worse with OSS plus SF-ELS (mean score 2.1 vs 1.8; P = .032). There were no deaths in either study and no serious adverse events considered related to the preparation. Bowel cleansing was not scored by colon segment. Adenoma detection was not compared between the regimens. OSS plus SF-ELS is a new, safe, and effective bowel preparation for colonoscopy. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  5. Scottish Bowel Screening Programme Colonoscopy Quality - scope for improvement?

    PubMed

    Quyn, A J; Fraser, C G; Stanners, G; Carey, F A; Rees, C J; Moores, B; Steele, R J

    2018-06-04

    The delivery of the Scottish Bowel Screening Programme (SBoSP) is rooted in the provision of a high quality, effective and participant-centred service. Safe and effective colonoscopy forms an integral part of the process. Additional accreditation as part of a multi-faceted programme for participating colonoscopists, as in England, does not exist in Scotland. This study aimed to describe the quality of colonoscopy in the SBoSP and compare this to the English national screening standards. Data were collected from the SBoSP between 2007 and 2014. End-points for analysis were caecal intubation, cancer, polyp and adenoma detection, and complications. Overall results were compared with 2012 published English national standards for screening and outcomes from 2006-2009. During the study period 53,332 participants attended for colonoscopy. Colonoscopy completion rate was 95.6% overall. The mean cancer detection rate (CDR) was 7.1%, the polyp detection rate (PDR) 45.7% and the adenoma detection rate (ADR) was 35.5%.The overall complication rate was 0.47%. Colonoscopy quality in the SBoSP has exceeded the standard set for screening colonoscopy in England, despite not adopting a multi-faceted programme for screening colonoscopy. However, the overall ADR in Scotland was 9.1% lower than that in England which has implications for colonoscopy quality and may have an impact on the cancer prevention rates, a key aim of the SBoSP. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Outpatient Provider Concentration and Commercial Colonoscopy Prices

    PubMed Central

    Pozen, Alexis

    2015-01-01

    The objective was to evaluate the magnitude of various contributors to outpatient commercial colonoscopy prices, including market- and provider-level factors, especially market share. We used adjudicated fee-for-service facility claims from a large commercial insurer for colonoscopies occurring in hospital outpatient department or ambulatory surgery center from October 2005 to December 2012. Claims were matched to provider- and market-level data. Linear fixed effects regressions of negotiated colonoscopy price were run on provider, system, and market characteristics. Markets were defined as counties. There were 178 433 claims from 169 providers (104 systems). The mean system market share was 76% (SD = 0.34) and the mean real (deflated) price was US$1363 (SD = 374), ranging from US$169 to US$2748. For every percentage point increase in a system or individual facility’s bed share, relative price increased by 2 to 4 percentage points; this result was stable across a number of specifications. Market population and price were also consistently positively related, though this relation was small in magnitude. No other factor explained price as strongly as market share. Price variation for colonoscopy was driven primarily by market share, of particular concern as the number of mergers increases in wake of the recession and the Affordable Care Act. Whether variation is justified by better quality care requires further research to determine whether quality is subsumed in prices. PMID:25870183

  7. One-day bowel preparation with polyethylene glycol 3350: an effective regimen for colonoscopy in children.

    PubMed

    Adamiak, Tonya; Altaf, Muhammad; Jensen, Michael K; Sultan, Mutaz; Ramprasad, Jonathan; Ciecierega, Thomas; Sherry, Karen; Miranda, Adrian

    2010-03-01

    Polyethylene glycol (PEG) 3350 is commonly used and has been proven safe and effective for the treatment of chronic constipation and as a 4-day bowel preparation in children. A 1-day PEG 3350 bowel preparation regimen has been recently developed for adults; however, data regarding its use in children are lacking. To evaluate the safety and effectiveness of a 1-day PEG 3350 regimen for bowel preparation in children before colonoscopy. Retrospective review. Tertiary-care center. This study involved all children prescribed a 1-day PEG 3350 bowel preparation regimen before colonoscopy at our center in 2008. We reviewed medical records of patients (< or = 18 years of age) who underwent colonoscopy during 2008 and received the 1-day bowel preparation regimen. Adequate preparation for colonoscopy, success of colonoscopy, and factors associated with inadequate bowel preparation. Inclusion criteria were met by 272 patients. The median age of the children receiving the 1-day PEG 3350 preparation regimen was 13.7 years (range 1.08-17.92 years). Fifty-two percent were male; 48% were female. The most common indications for colonoscopy included abdominal pain (65%), bloody stools (29%), diarrhea (21%), and weight loss (18%). The 1-day bowel preparation regimen was effective in 253 patients (93%). The indication for colonoscopy, the age of the child, or a history of constipation did not significantly alter the success rate of colonoscopy. A retrospective study at one tertiary-care center. The 1-day PEG 3350 bowel preparation regimen is safe and effective and should be considered for use as preparation for colonoscopy in children. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. Old habits die hard: a case study on how new ways of teaching colonoscopy affect the habitus of experienced clinicians

    PubMed Central

    Lund, Ole; Andersen, Berit

    2016-01-01

    Objectives The purpose of this study is to explore the habitual constraints and opportunities that affect how experienced clinicians learn new skills and, in particular, how new ways of teaching can influence these. Methods We conducted a case study based on a specialized training program for colonoscopy services in Denmark. Data was obtained from a short-term ethnographic fieldwork and in-depth interviews during this program. Participants were 12 experienced colonoscopists and three expert colonoscopy trainers from Denmark and UK. The analysis of data involved categorization, inductive coding, and theoretical reading inspired by sociological theory. Results The experienced clinicians' responsiveness to training was shaped by an underlying logic of colonoscopy practice that was characterized by tacit skills, routine work, lower status, skepticism and self-protectiveness. In order to overcome these habitual constraints, the trainers applied a pedagogical approach based on four methods: 1) intellectualization: 'academization' of skills and competencies, 2) sensing and scaffolding: hands-on experiences and learning by doing, 3) asymmetry: accentuating the authority and respect of the trainer, and 4) relation-building: building relationship and engagement between trainer and clinician. This multi-dimensional approach to teaching enabled the trainers to affect the clinicians' logic of practice and to create buy-in (so-called illusio). Conclusions Clinical skills include socially constructed behaviors and unconscious competences which affect experienced clinicians' responsiveness to continuing medical education. This study suggests four educational strategies that may help trainers to establish new logics of practice in experienced clinicians and to improve the clinicians' conscious competence. PMID:27643986

  9. Old habits die hard: a case study on how new ways of teaching colonoscopy affect the habitus of experienced clinicians.

    PubMed

    Lund, Ole; Andersen, Berit; Christensen, Mette K

    2016-09-19

    The purpose of this study is to explore the habitual constraints and opportunities that affect how experienced clinicians learn new skills and, in particular, how new ways of teaching can influence these.   We conducted a case study based on a specialized training program for colonoscopy services in Denmark. Data was obtained from a short-term ethnographic fieldwork and in-depth interviews during this program. Participants were 12 experienced colonoscopists and three expert colonoscopy trainers from Denmark and UK. The analysis of data involved categorization, inductive coding, and theoretical reading inspired by sociological theory. The experienced clinicians' responsiveness to training was shaped by an underlying logic of colonoscopy practice that was characterized by tacit skills, routine work, lower status, skepticism and self-protectiveness. In order to overcome these habitual constraints, the trainers applied a pedagogical approach based on four methods: 1) intellectualization: 'academization' of skills and competencies, 2) sensing and scaffolding: hands-on experiences and learning by doing, 3) asymmetry: accentuating the authority and respect of the trainer, and 4) relation-building: building relationship and engagement between trainer and clinician. This multi-dimensional approach to teaching enabled the trainers to affect the clinicians' logic of practice and to create buy-in (so-called illusio). Clinical skills include socially constructed behaviors and unconscious competences which affect experienced clinicians' responsiveness to continuing medical education. This study suggests four educational strategies that may help trainers to establish new logics of practice in experienced clinicians and to improve the clinicians' conscious competence.

  10. Early Versus Delayed Colonoscopy in Hospitalized Patients With Lower Gastrointestinal Bleeding: A Meta-Analysis.

    PubMed

    Sengupta, Neil; Tapper, Elliot B; Feuerstein, Joseph D

    2017-04-01

    Early colonoscopy is recommended for patients with severe lower gastrointestinal bleeding (LGIB). There is limited data as to whether this is associated with improved outcomes. We performed a meta-analysis of studies comparing early (<24 h) versus delayed colonoscopy (>24 h). PubMed, Embase, and Web of Science were searched for manuscripts using colonoscopy as a diagnostic/treatment modality for patients hospitalized with LGIB. Studies were included if data were available on outcomes comparing early and delayed colonoscopy. Articles were reviewed for time to colonoscopy, rebleeding, mortality, length of stay (LOS), surgery, interventions, localization of LGIB, and number of packed red blood cells. Pooled measures were reported using the Mantel-Haenszel method. A total of 8491 studies were assessed of which 6 were included. There were 422 patients in the early arm and 479 in the delayed arm. There were no differences in age (64.2 vs. 65.7, P=0.85), admission hemoglobin (10.3 vs. 10.3 g/dL, P=0.96), LOS (5.21 vs. 6.09, P=0.52), and packed red blood cells transfusion (2.37 vs. 2.35, P=0.92) between the groups. In hospital mortality [odds ratio (OR), 1.64; 95% confidence interval (CI), 0.51-5.32], rebleeding (OR, 1.38; 95% CI, 0.85-2.23) and need for surgery (OR, 0.89; 95% CI, 0.42-1.89) were not different in delayed versus early colonoscopy. Early colonoscopy was associated with a higher detection of bleeding source (OR, 2.97; 95% CI, 2.11-4.19) and endoscopic intervention (OR, 3.99; 95% CI, 2.59-6.13). Early colonoscopy is not associated with reduced rebleeding, LOS, or surgery but is associated with a higher rate of source localization and endoscopic intervention.

  11. Factors affecting successful colonoscopy procedures: Single-center experience.

    PubMed

    Kozan, Ramazan; Yılmaz, Tonguç Utku; Baştuğral, Uygar; Kerimoğlu, Umut; Yavuz, Yücel

    2018-01-01

    Colonoscopy is a gold standard procedure for several colon pathologies. Successful colonoscopy means demonstration of the ileocecal valve and determination of colon polyps. Here we aimed to evaluate our colonoscopy success and results. This retrospective descriptive study was performed in İstanbul Eren hospital endoscopy unit between 2012 and 2015. Colonoscopy results and patient demographics were obtained from the hospital database. All colonoscopy procedures were performed under general anesthesia and after full bowel preparation. In all, 870 patients were included to the study. We reached to the cecum in 850 (97.8%) patients. We were unable to reach the cecum in patients who were old and obese and those with previous lower abdominal operations. Angulation, inability to move forward, and tortuous colon were the reasons for inability to reach the cecum. Total 203 polyp samplings were performed in 139 patients. We performed 1, 2, and 3 polypectomies in 97, 28, and 10 patients, respectively. There were 29 (3.3%) colorectal cancers in our series. There was no mortality or morbidity in our study. General anesthesia and full bowel preparation may be the reason for increased success of colonoscopy. Increased experience and patient-endoscopist cooperation increased the rate of cecum access and polyp resection and decreased the complication rate.

  12. Importance of reporting segmental bowel preparation scores during colonoscopy in clinical practice

    PubMed Central

    Jain, Deepanshu; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury; Singhal, Shashideep

    2015-01-01

    AIM: To evaluate the impact of reporting bowel preparation using Boston Bowel Preparation Scale (BBPS) in clinical practice. METHODS: The study was a prospective observational cohort study which enrolled subjects reporting for screening colonoscopy. All subjects received a gallon of polyethylene glycol as bowel preparation regimen. After colonoscopy the endoscopists determined quality of bowel preparation using BBPS. Segmental scores were combined to calculate composite BBPS. Site and size of the polyps detected was recorded. Pathology reports were reviewed to determine advanced adenoma detection rates (AADR). Segmental AADR’s were calculated and categorized based on the segmental BBPS to determine the differential impact of bowel prep on AADR. RESULTS: Three hundred and sixty subjects were enrolled in the study with a mean age of 59.2 years, 36.3% males and 63.8% females. Four subjects with incomplete colonoscopy due BBPS of 0 in any segment were excluded. Based on composite BBPS subjects were divided into 3 groups; Group-0 (poor bowel prep, BBPS 0-3) n = 26 (7.3%), Group-1 (Suboptimal bowel prep, BBPS 4-6) n = 121 (34%) and Group-2 (Adequate bowel prep, BBPS 7-9) n = 209 (58.7%). AADR showed a linear trend through Group-1 to 3; with an AADR of 3.8%, 14.8% and 16.7% respectively. Also seen was a linear increasing trend in segmental AADR with improvement in segmental BBPS. There was statistical significant difference between AADR among Group 0 and 2 (3.8% vs 16.7%, P < 0.05), Group 1 and 2 (14.8% vs 16.7%, P < 0.05) and Group 0 and 1 (3.8% vs 14.8%, P < 0.05). χ2 method was used to compute P value for determining statistical significance. CONCLUSION: Segmental AADRs correlate with segmental BBPS. It is thus valuable to report segmental BBPS in colonoscopy reports in clinical practice. PMID:25852286

  13. Importance of reporting segmental bowel preparation scores during colonoscopy in clinical practice.

    PubMed

    Jain, Deepanshu; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury; Singhal, Shashideep

    2015-04-07

    To evaluate the impact of reporting bowel preparation using Boston Bowel Preparation Scale (BBPS) in clinical practice. The study was a prospective observational cohort study which enrolled subjects reporting for screening colonoscopy. All subjects received a gallon of polyethylene glycol as bowel preparation regimen. After colonoscopy the endoscopists determined quality of bowel preparation using BBPS. Segmental scores were combined to calculate composite BBPS. Site and size of the polyps detected was recorded. Pathology reports were reviewed to determine advanced adenoma detection rates (AADR). Segmental AADR's were calculated and categorized based on the segmental BBPS to determine the differential impact of bowel prep on AADR. Three hundred and sixty subjects were enrolled in the study with a mean age of 59.2 years, 36.3% males and 63.8% females. Four subjects with incomplete colonoscopy due BBPS of 0 in any segment were excluded. Based on composite BBPS subjects were divided into 3 groups; Group-0 (poor bowel prep, BBPS 0-3) n = 26 (7.3%), Group-1 (Suboptimal bowel prep, BBPS 4-6) n = 121 (34%) and Group-2 (Adequate bowel prep, BBPS 7-9) n = 209 (58.7%). AADR showed a linear trend through Group-1 to 3; with an AADR of 3.8%, 14.8% and 16.7% respectively. Also seen was a linear increasing trend in segmental AADR with improvement in segmental BBPS. There was statistical significant difference between AADR among Group 0 and 2 (3.8% vs 16.7%, P < 0.05), Group 1 and 2 (14.8% vs 16.7%, P < 0.05) and Group 0 and 1 (3.8% vs 14.8%, P < 0.05). χ(2) method was used to compute P value for determining statistical significance. Segmental AADRs correlate with segmental BBPS. It is thus valuable to report segmental BBPS in colonoscopy reports in clinical practice.

  14. Comparison of Colonoscopy Quality Measures Across Various Practice Settings and the Impact of Performance Scorecards.

    PubMed

    Inra, Jennifer A; Nayor, Jennifer; Rosenblatt, Margery; Mutinga, Muthoka; Reddy, Sarathchandra I; Syngal, Sapna; Kastrinos, Fay

    2017-04-01

    Quality performance measures for screening colonoscopy vary among endoscopists. The impact of practice setting is unknown. We aimed to (1) compare screening colonoscopy performance measures among three different US practice settings; (2) evaluate factors associated with adenoma detection; and (3) assess a scorecard intervention on performance metrics. This multi-center prospective study compared patient, endoscopist, and colonoscopy characteristics performed at a tertiary care hospital (TCH), community-based hospital (CBH), and private practice group (PPG). Withdrawal times (WT), cecal intubation, and adenoma detection rates (ADR) were compared by site at baseline and 12 weeks following scorecard distribution. Generalized linear mixed models identified factors associated with adenoma detection. Twenty-eight endoscopists performed colonoscopies on 1987 asymptomatic, average-risk individuals ≥50 years. Endoscopist and patient characteristics were similar across sites. The PPG screened more men (TCH: 42.8%, CBH: 45.0%, PPG: 54.2%; p < 0.0001). Preparation quality varied with good/excellent results in 70.6, 88.3, and 92% of TCH, CBH, and PPG cases, respectively (p < 0.0001). Male ADRs, cecal intubation, and WT exceeded recommended benchmarks despite variable results at each site; female ADRs were <15% at the PPG which screened the fewest females. Performance remained unchanged following scorecard distribution. Adenoma detection was associated with increasing patient age, male gender, WT, adequate preparation, but not practice setting. Each practice performed high-quality screening colonoscopy. Scorecards did not improve performance metrics. Preparation quality varies among practice settings and can be modified to improve adenoma detection.

  15. Patient-to-patient transmission of hepatitis C virus (HCV) during colonoscopy diagnosis

    PubMed Central

    2010-01-01

    Background No recognized risk factors can be identified in 10-40% of hepatitis C virus (HCV)-infected patients suggesting that the modes of transmission involved could be underestimated or unidentified. Invasive diagnostic procedures, such as endoscopy, have been considered as a potential HCV transmission route; although the actual extent of transmission in endoscopy procedures remains controversial. Most reported HCV outbreaks related to nosocomial acquisition have been attributed to unsafe injection practices and use of multi-dose vials. Only a few cases of likely patient-to-patient HCV transmission via a contaminated colonoscope have been reported to date. Nosocomial HCV infection may have important medical and legal implications and, therefore, possible transmission routes should be investigated. In this study, a case of nosocomial transmission of HCV from a common source to two patients who underwent colonoscopy in an endoscopy unit is reported. Results A retrospective epidemiological search after detection of index cases revealed several potentially infective procedures: sample blood collection, use of a peripheral catheter, anesthesia and colonoscopy procedures. The epidemiological investigation showed breaches in colonoscope reprocessing and deficiencies in the recording of valuable tracing data. Direct sequences from the NS5B region were obtained to determine the extent of the outbreak and cloned sequences from the E1-E2 region were used to establish the relationships among intrapatient viral populations. Phylogenetic analyses of individual sequences from viral populations infecting the three patients involved in the outbreak confirmed the patient pointed out by the epidemiological search as the source of the outbreak. Furthermore, the sequential order in which the patients underwent colonoscopy correlates with viral genetic variability estimates. Conclusions Patient-to-patient transmission of HCV could be demonstrated although the precise route of transmission remained unclear. Viral genetic variability is proposed as a useful tool for tracing HCV transmission, especially in recent transmissions. PMID:20825635

  16. Colonoscopy in automated peritoneal dialysis patients: value of prophylactic antibiotics: a prospective study on a single antibiotic.

    PubMed

    Al-Hwiesh, Abdullah K; Abdul-Rahman, Ibrahiem S; Hussameldeen, Mohammad A; Al-Audah, Nadia; Abdelrahman, Abdalla; Moaigel, Hala M; El-Salamony, Tamer; Noor, Abdul-Salam; Al-Osail, Aisha; Al-Sayel, Dalal; Al-Dossari, Nourah

    2017-10-13

    To evaluate the need for prophylactic antibiotics in automated peritoneal dialysis (APD) patients undergoing flexible colonoscopy. A total of 93 patients on automated peritoneal dialysis (APD) undergoing diagnostic colonoscopy were enrolled in a prospective, randomized study. Patients were randomized into 2 age- and sex-matched groups; group A (46 patients) with intraperitoneal (IP) ceftazidime prior to colonoscopy and group B (47 patients) without prophylactic antibiotics. The relations between peritonitis and different parameters were analyzed. Of all colonoscopies, 60.2% showed normal findings, 17.2% with colonic polyps at different sites, 12.9% with angiodysplastic-like lesions, 5.4% with colonic ulcer(s), 3.2% with diverticulae without diverticulitis and 1.1% had transverse colon stricture. Post-colonoscopy peritonitis was documented in 3 (6.5%) and 4 (8.5%) patients in groups A and B, respectively (p = 0.2742); the causative organisms were mainly gram negative bacteria. Polypectomy was not associated with increased peritonitis episodes. By multiple logistic regression analysis, diabetes mellitus was the only independent variable that entered into the best predictive equation over the development of post-colonoscopy peritonitis but not antibiotic use. The relation between prophylactic antibiotic use prior to colonoscopy in APD patients and the risk of peritonitis was lacking. Only diabetes mellitus appears to be of significance. Polypectomy did not increase peritonitis episodes.

  17. A novel balloon colonoscope detects significantly more simulated polyps than a standard colonoscope in a colon model.

    PubMed

    Hasan, Nazia; Gross, Seth A; Gralnek, Ian M; Pochapin, Mark; Kiesslich, Ralf; Halpern, Zamir

    2014-12-01

    Although standard colonoscopy is considered the optimal test to detect adenomas, it can have a significant adenoma miss rate. A major contributing factor to high miss rates is the inability to visualize adenomas behind haustral folds and at anatomic flexures. To compare the diagnostic yield of balloon-assisted colonoscopy versus standard colonoscopy in the detection of simulated polyps in a colon model. Prospective, cohort study. International gastroenterology meeting. A colon model composed of elastic material, which mimics the flexible structure of haustral folds, allowing for dynamic responses to balloon inflation, with embedded simulated colon polyps (n = 12 silicone "polyps"). Fifty gastroenterologists were recruited to identify simulated colon polyps in a colon model, first using standard colonoscopy immediately followed by balloon-assisted colonoscopy. Detection of simulated polyps. The median polyp detection rate for all simulated polyps was significantly higher with balloon-assisted as compared with standard colonoscopy (91.7% vs 45.8%, respectively; P < .0001). The significantly higher simulated polyp detection rate with balloon-assisted versus standard colonoscopy was notable both for non-obscured polyps (100.0% vs 75.0%; P < .0001) and obscured polyps (88.0% vs 25.0%; P < .0001). Non-randomized design, use of a colon model, and simulated colon polyps. As compared with standard colonoscopy, balloon-assisted colonoscopy detected significantly more obscured and non-obscured simulated polyps in a colon model. Clinical studies in human participants are being pursued to further evaluate this new colonoscopic technology. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  18. Pros and cons of colonoscopy in management of acute lower gastrointestinal bleeding

    PubMed Central

    Lhewa, Dekey Y; Strate, Lisa L

    2012-01-01

    Acute lower gastrointestinal bleeding (LGIB) is a frequent gastrointestinal cause of hospitalization, particularly in the elderly, and its incidence appears to be on the rise. Endoscopic and radiographic measures are available for the evaluation and treatment of LGIB including flexible sigmoidoscopy, colonoscopy, angiography, radionuclide scintigraphy and multi-detector row computed tomography. Although no modality has emerged as the gold standard in the management of LGIB, colonoscopy is the current preferred initial test for the majority of the patients presenting with hematochezia felt to be from a colon source. Colonoscopy has the ability to diagnose all sources of bleeding from the colon and, unlike the radiologic modalities, does not require active bleeding at the time of the examination. In addition, therapeutic interventions such as cautery and endoclips can be applied to achieve hemostasis and prevent recurrent bleeding. Studies suggest that colonoscopy, particularly when performed early in the hospitalization, can decrease hospital length of stay, rebleeding and the need for surgery. However, results from available small trials are conflicting and larger, multicenter studies are needed. Compared to other management options, colonoscopy is a safe procedure with complications reported in less than 2% of patients, including those undergoing urgent examinations. The requirement of bowel preparation (typically 4 or more liters of polyethylene glycol), the logistical complexity of coordinating after-hours colonoscopy, and the low prevalence of stigmata of hemorrhage complicate the use of colonoscopy for LGIB, particularly in urgent situations. This review discusses the above advantages and disadvantages of colonoscopy in the management of acute lower gastrointestinal bleeding in further detail. PMID:22468081

  19. Improving the Yield of Histological Sampling in Patients With Suspected Colorectal Cancer During Colonoscopy by Introducing a Colonoscopy Quality Assurance Program.

    PubMed

    Gado, Ahmed; Ebeid, Basel; Abdelmohsen, Aida; Axon, Anthony

    2011-08-01

    Masses discovered by clinical examination, imaging or endoscopic studies that are suspicious for malignancy typically require biopsy confirmation before treatment is initiated. Biopsy specimens may fail to yield a definitive diagnosis if the lesion is extensively ulcerated or otherwise necrotic and viable tumor tissue is not obtained on sampling. The diagnostic yield is improved when multiple biopsy samples (BSs) are taken. A colonoscopy quality-assurance program (CQAP) was instituted in 2003 in our institution. The aim of this study was to determine the effect of instituting a CQAP on the yield of histological sampling in patients with suspected colorectal cancer (CRC) during colonoscopy. Initial assessment of colonoscopy practice was performed in 2003. A total of five patients with suspected CRC during colonoscopy were documented in 2003. BSs confirmed CRC in three (60%) patients and were nondiagnostic in two (40%). A quality-improvement process was instituted which required a minimum six BSs with adequate size of the samples from any suspected CRC during colonoscopy. A total of 37 patients for the period 2004-2010 were prospectively assessed. The diagnosis of CRC was confirmed with histological examination of BSs obtained during colonoscopy in 63% of patients in 2004, 60% in 2005, 50% in 2006, 67% in 2007, 100% in 2008, 67% in 2009 and 100% in 2010. The yield of histological sampling increased significantly ( p <0.02) from 61% in 2004-2007 to 92% in 2008-2010. The implementation of a quality assurance and improvement program increased the yield of histological sampling in patients with suspected CRC during colonoscopy.

  20. Detection rate and predictive factors of sessile serrated polyps in an organised colorectal cancer screening programme with immunochemical faecal occult blood test: the EQuIPE study (Evaluating Quality Indicators of the Performance of Endoscopy).

    PubMed

    Zorzi, Manuel; Senore, Carlo; Da Re, Filippo; Barca, Alessandra; Bonelli, Luigina Ada; Cannizzaro, Renato; de Pretis, Giovanni; Di Furia, Lucia; Di Giulio, Emilio; Mantellini, Paola; Naldoni, Carlo; Sassatelli, Romano; Rex, Douglas K; Zappa, Marco; Hassan, Cesare

    2017-07-01

    To assess detection rate and predictive factors of sessile serrated polyps (SSPs) in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). Data from a case series of colonoscopies of FIT-positive subjects were provided by 44 Italian CRC screening programmes. Data on screening history, endoscopic procedure and histology results, and additional information on the endoscopy centre and the endoscopists were collected, including the age-standardised and sex-standardised adenoma detection rate (ADR) of the individual endoscopists. The SSP detection rate (SSP-DR) was assessed for the study population. To identify SSP-predictive factors, multilevel analyses were performed according to patient/centre/endoscopist characteristics. We analysed 72 021 colonoscopies, of which 1295 presented with at least one SSP (SSP-DR 1.8%; 95% CI 1.7% to 1.9%). At the per-patient level, SSP-DR was associated with males (OR 1.35; 95% CI 1.17 to 1.54) and caecal intubation (OR 3.75; 95% CI 2.22 to 6.34), but not with the FIT round. The presence of at least one advanced adenoma was more frequent among subjects with SSPs than those without (OR 2.08; 95% CI 1.86 to 2.33). At the per-endoscopist level, SSP-DR was associated with ADR (third vs first ADR quartile: OR 1.55; 95% CI 1.03 to 2.35; fourth vs first quartile: OR 1.89; 95% CI 1.24 to 2.90). The low prevalence of SSPs and the lack of association with the FIT round argue against SSP as a suitable target for FIT-based organised programmes. Strict association of SSP-DR with the key colonoscopy quality indicators, namely caecal intubation rate and high ADR further marginalises the need for SSP-specific quality indicators in FIT-based programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. A randomized, controlled trial to confirm the beneficial effects of the water method on U.S. veterans undergoing colonoscopy with the option of on-demand sedation.

    PubMed

    Leung, Joseph; Mann, Surinder; Siao-Salera, Rodelei; Ransibrahmanakul, Kanat; Lim, Brian; Canete, Wilhelmina; Samson, Laramie; Gutierrez, Rebeck; Leung, Felix W

    2011-01-01

    Sedation for colonoscopy discomfort imposes a recovery-time burden on patients. The water method permitted 52% of patients accepting on-demand sedation to complete colonoscopy without sedation. On-site and at-home recovery times were not reported. To confirm the beneficial effect of the water method and document the patient recovery-time burden. Randomized, controlled trial, with single-blinded, intent-to-treat analysis. Veterans Affairs outpatient endoscopy unit. This study involved veterans accepting on-demand sedation for screening and surveillance colonoscopy. Air versus water method for colonoscope insertion. Proportion of patients completing colonoscopy without sedation, cecal intubation rate, medication requirement, maximum discomfort (0 = none, 10 = severe), procedure-related and patient-related outcomes. One hundred veterans were randomized to the air (n = 50) or water (n = 50) method. The proportions of patients who could complete colonoscopy without sedation in the water group (78%) and the air group (54%) were significantly different (P = .011, Fisher exact test), but the cecal intubation rate was similar (100% in both groups). Secondary analysis (data as Mean [SD]) shows that the water method produced a reduction in medication requirement: fentanyl, 12.5 (26.8) μg versus 24.0 (30.7) μg; midazolam, 0.5 (1.1) mg versus 0.94 (1.20) mg; maximum discomfort, 2.3 (1.7) versus 4.9 (2.0); recovery time on site, 8.4 (6.8) versus 12.3 (9.4) minutes; and recovery time at home, 4.5 (9.2) versus 10.9 (14.0) hours (P = .049; P = .06; P = .0012; P = .0199; and P = .0048, respectively, t test). Single Veterans Affairs site, predominantly male population, unblinded examiners. This randomized, controlled trial confirms the reported beneficial effects of the water method. The combination of the water method with on-demand sedation minimizes the patient recovery-time burden. ( NCT00920751.). Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. Colorectal cancer screening behaviour and associated factors among Chinese aged 50 and above in Hong Kong - a population-based survey.

    PubMed

    So, W K W; Choi, K C; Chan, D N S; Shiu, A T Y; Ho, S S M; Chan, H Y L; Lam, W W T; Cheng, K K F; Goggins, W; Chan, C W H

    2012-09-01

    This study reports the uptake rate of colorectal cancer screening among Chinese people aged 50 or above and the identified factors associated with the likelihood of undergoing such screening. A cross-sectional population-based telephone survey was conducted in Hong Kong during the period 2 to 28 May 2007. The survey covered demographics, perceived health status and susceptibility to cancer, utilisation of complementary medicine, family history of cancer and cancer screening behaviour. The survey was completed by 2004 Hong Kong Chinese residents aged 50 or older (response rate = 66.6%). The uptake rate of a fecal occult blood test and a colonoscopy was 12% and 19% respectively. Factors associated with colorectal cancer screening behaviour included: male participants, ex-smokers, with cancer or other serious disease, a family history of cancer, perceived health status fair or poor, regular visits to a doctor to look after health, and utilisation of complementary medicine. The uptake rate of this study population was low though an increasing trend did appear. Heath education and promotion programmes may focus on these identified factors to facilitate colorectal cancer screening in a Chinese population. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. The utility of Google Trends data to examine interest in cancer screening.

    PubMed

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-06-08

    We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. State-level data across the USA. Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Adherence to Physician Recommendations for Surveillance in Opportunistic Colorectal Cancer Screening: The Necessity of Organized Surveillance

    PubMed Central

    Stock, Christian; Holleczek, Bernd; Hoffmeister, Michael; Stolz, Thomas; Stegmaier, Christa; Brenner, Hermann

    2013-01-01

    Background Limited evidence exists on the utilization of surveillance colonoscopy in colorectal cancer (CRC) screening programs. We assessed adherence to physician recommendations for surveillance in opportunistic CRC screening in Germany. Methods A follow-up study of screening colonoscopy participants in 2007-2009 in Saarland, Germany, was conducted using health insurance claims data. Utilization of additional colonoscopies through to 2011 was ascertained. Adherence to surveillance intervals of 3, 6, 12 and 36 months, defined as having had colonoscopy at 2.5 to 4, 5 to 8, 10.5 to 16 and 33 to 48 months, respectively (i.e., tolerating a delay of 33% of each interval) was assessed. Potential predictors of non-adherence were investigated using logistic regression analysis. Results A total of 20,058 screening colonoscopy participants were included in the study. Of those with recommended surveillance intervals of 3, 6, 12 and 36 months, 46.5% (95%-confidence interval [CI]: 37.3-55.7%), 38.5% (95%-CI: 29.6-47.3%), 25.4% (95%-CI: 21.2-29.6%) and 28.0% (95%-CI: 25.5-30.5%), respectively, had a subsequent colonoscopy within the specified margins. Old age, longer recommended surveillance interval, not having had polypectomy at screening and negative colonoscopy were statistically significant predictors of non-adherence. Conclusion This study suggests frequent non-adherence to physician recommendations for surveillance colonoscopy in community practice. Increased efforts to improve adherence, including introduction of more elements of an organized screening program, seem necessary to assure a high-quality CRC screening process. PMID:24324821

  5. Serious complications within 30 days of screening and surveillance colonoscopy are uncommon

    PubMed Central

    Ko, Cynthia W.; Riffle, Stacy; Michaels, LeAnn; Morris, Cynthia; Holub, Jennifer; Shapiro, Jean A.; Ciol, Marcia A.; Kimmey, Michael B.; Seeff, Laura C.; Lieberman, David

    2009-01-01

    Background & Aims The risk of serious complications after colonoscopy has important implications for the overall benefits of colorectal cancer screening programs. We evaluated the incidence of serious complications within 30 days after screening or surveillance colonoscopies in diverse clinical settings and to identify potential risk factors for complications. Methods Patients age 40 and over undergoing colonoscopy for screening, surveillance, or evaluation based an abnormal result from another screening test were enrolled through the National Endoscopic Database (CORI). Patients completed a standardized telephone interview approximately 7 and 30 days after their colonoscopy. We estimated the incidence of serious complications within 30 days of colonoscopy and identified risk factors associated with complications using logistic regression analyses. Results 21,375 patients were enrolled. Gastrointestinal bleeding requiring hospitalization occurred in 34 patients (incidence 1.59/1000 exams; 95% confidence interval [CI] 1.10–2.22). Perforations occurred in 4 patients (0.19/1000 exams; 95% CI 0.05–0.48), diverticulitis requiring hospitalization in 5 patients (0.23/1000 exams; 95% CI 0.08–0.54), and post-polypectomy syndrome in 2 patients (0.09/1000 exams; 95%CI 0.02–0.30). The overall incidence of complications directly related to colonoscopy was 2.01 per 1000 exams (95%CI 1.46–2.71). Two of the four perforations occurred without biopsy or polypectomy. The risk of complications increased with pre-procedure warfarin use and performance of polypectomy with cautery. Conclusions Complications after screening or surveillance colonoscopy are uncommon. Risk factors for complications include warfarin use and polypectomy with cautery. PMID:19850154

  6. Simulation-Based Training of Non-Technical Skills in Colonoscopy: Protocol for a Randomized Controlled Trial.

    PubMed

    Khan, Rishad; Scaffidi, Michael A; Walsh, Catharine M; Lin, Peter; Al-Mazroui, Ahmed; Chana, Barinder; Kalaichandran, Ruben; Lee, Woojin; Grantcharov, Teodor P; Grover, Samir C

    2017-08-04

    Non-technical skills (NTS), such as communication and professionalism, contribute to the safe and effective completion of procedures. NTS training has previously been shown to improve surgical performance. Moreover, increases in NTS have been associated with improved clinical endoscopic performance. Despite this evidence, NTS training has not been tested as an intervention in endoscopy. The aim of this study is to evaluate the effectiveness of a simulation-based training (SBT) curriculum of NTS on novice endoscopists' performance of clinical colonoscopy. Novice endoscopists were randomized to 2 groups. The control group received 4 hours of interactive didactic sessions on colonoscopy theory and 6 hours of SBT. Hours 5 and 6 of the SBT were integrated scenarios, wherein participants interacted with a standardized patient and nurse, while performing a colonoscopy on the virtual reality (VR) simulator. The NTS (intervention) group received the same teaching sessions but the last hour was focused on NTS teaching. The NTS group also reviewed a checklist of tasks relevant to NTS concepts prior to each integrated scenario case and was provided with dedicated feedback on their NTS performance during the integrated scenario practice. All participants were assessed at baseline, immediately after training, and 4 to 6 weeks post-training. The primary outcome measure is colonoscopy-specific performance in the clinical setting. In total, 42 novice endoscopists completed the study. Data collection and analysis is ongoing. We anticipate completion of all assessments by August 2017. Data analysis, manuscript writing, and subsequent submission for publication is expected to be completed by December 2017. Results from this study may inform the implementation of NTS training into postgraduate gastrointestinal curricula. NTS curricula may improve attitudes towards patient safety and self-reflection among trainees. Moreover, enhanced NTS may lead to superior clinical performance and outcomes in colonoscopy. Clinicaltrial.gov NCT02877420; https://www.clinicaltrials.gov/ct2/show/NCT02877420 (Archived by WebCite at http://www.webcitation.org/6rw94ubXX NCT02877420). ©Rishad Khan, Michael A Scaffidi, Catharine M Walsh, Peter Lin, Ahmed Al-Mazroui, Barinder Chana, Ruben Kalaichandran, Woojin Lee, Teodor P Grantcharov, Samir C Grover. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 04.08.2017.

  7. Colonoscopic Findings in Patients With Incidental Colonic Focal FDG Uptake.

    PubMed

    Keyzer, Caroline; Dhaene, Benjamin; Blocklet, Didier; De Maertelaer, Viviane; Goldman, Serge; Gevenois, Pierre Alain

    2015-05-01

    The purpose of this study was to investigate the nature of FDG-avid and non-FDG-avid lesions detected at colonoscopy in patients presenting with incidental focal colonic FDG uptake at PET/CT. Among 9073 patients who underwent PET/CT over a 4-year period, 82 patients without a history of colonic disease had focal colonic FDG uptake and underwent colonoscopy. In consensus, a radiologist and a nuclear physician read images from these PET/CT examinations. They recorded the location of focal FDG uptake in the colon and associated CT abnormalities and measured maximum standardized uptake value (SUVmax) and metabolic volume (MV). Readings were performed twice--first without and second with knowledge of lesion location at colonoscopy. The final diagnosis was based on colonoscopic findings and histopathologic results categorized into benign, premalignant, or malignant. One hundred seven foci of colonic FDG uptake at PET/CT and 150 lesions at colonoscopy were detected. Among 107 foci of FDG uptake, 65 (61%) corresponded to a lesion at colonoscopy (true-positive findings), and 42 (39%) did not (false-positive findings). Among 150 lesions found at colonoscopy, 85 (57%) were not FDG avid (false-negative findings). The MV of true-positive findings was lower than that of false-positive findings (4.0 ± 0.4 cm(3) vs 6.2 ± 0.7 cm(3); p = 0.006), but SUVmax did not differ (7.4 ± 0.5 vs 7.7 ± 0.5; p = 0.649). Considering the histopathologic categories of the lesions and the false-positive findings, there was no difference in SUVmax (p = 0.103), but MV was lower in premalignant lesions than in false-positive findings (p = 0.005). Focal colonic FDG uptake may indicate the presence of a benign, pre-malignant, or malignant lesion. Subsequent colonoscopy should not be restricted to the colonic site of FDG uptake.

  8. Clinical correlates of trichuriasis diagnosed at colonoscopy.

    PubMed

    Jha, Ashish Kumar; Goenka, Mahesh Kumar; Suchismita, Arya

    2017-09-01

    Diagnosis of Trichuris trichiura infestations is usually based on identification of barrel-shaped ova in stool, but is frequently missed on stool microscopy. We describe the clinical profile of patients in whom Trichuris infection was incidentally diagnosed at colonoscopy. In a cross-sectional study, patients with colonoscopic diagnosis of trichuriasis were enrolled from the endoscopy unit in a tertiary care center. Blood and stool samples were collected from all those who were willing to participate and provide samples. Sixty-two patients participated, with mean (SD) age of 50.5 (13.6) years and male to female ratio of 40:22. Abdominal pain (61.2%) and/or altered bowel habits (32.2%) were the most common indication for colonoscopy. Most (66.6%) of the Trichuris were located in the cecum and ascending colon. Majority of the patients had live worms, either motile or adhering to the colonic mucosa. The number of worms was single or a few (<15) in 74.2% of patients. Out of 62 patients, 16 (25.8%) had relatively heavy load of parasites. Most patients had normal colonoscopic findings (80.6%). Periappendicular and/or cecal ulcerations/erosions were the most common (16.1%) abnormalities noted. Stool examination showed parasite ova only in four (6.4%) patients. In conclusion, colonoscopy was better than stool microscopy for the diagnosis of trichuriasis in our study.

  9. Motivational interviewing and screening colonoscopy in high-risk individuals. A randomized controlled trial.

    PubMed

    Salimzadeh, Hamideh; Khabiri, Roghaye; Khazaee-Pool, Maryam; Salimzadeh, Somayeh; Delavari, Alireza

    2018-06-01

    To measure the impact of motivational interviewing (MI) on cancer knowledge and screening practice among first degree relatives (FDRs) of patients with colon cancer. This randomized controlled trial targeted patients with colon cancer first to recruit their possible FDRs. Digit randomization of the eligible index patients into intervention or control groups resulted in allocating their belonging FDRs to the same study arm. FDRs (n = 120) in intervention arm received MI counseling on phone by a trained oncology nurse and FDRs (n = 120) in control group received standard generic information by a physician on phone. Primary outcome was the rate of documented colonoscopy in FDRs within six months after the baseline. A total of 227 FDRs were followed up, 115 in the intervention and 112 in the control group. At follow-up, the uptake of screening colonoscopy in the intervention group was 83.5% versus 48.2% in controls (crude odds ratio, 5.4; 95% confidence interval, 2.9-10.0, P < .001). This was the first randomized controlled trial in Iran that confirmed the efficaciousness of a phone-based MI counseling in improving colonoscopy uptake among family members of patients with colon cancer. Phone-based motivational counseling that involves trained nurses or health providers seems to be feasible approach in Iran health system and enhances screening for colon cancer. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. The SAFE-T assessment tool: derivation and validation of a web-based application for point-of-care evaluation of gastroenterology fellow performance in colonoscopy.

    PubMed

    Kumar, Navin L; Kugener, Guillaume; Perencevich, Molly L; Saltzman, John R

    2018-01-01

    Attending assessment is a critical part of endoscopic education for gastroenterology fellows. The aim of this study was to develop and validate a concise assessment tool to evaluate real-time fellow performance in colonoscopy administered via a web-based application. The Skill Assessment in Fellow Endoscopy Training (SAFE-T) tool was derived as a novel 5-question evaluation tool that captures both summative and formative feedback adapted into a web-based application. A prospective study of 15 gastroenterology fellows (5 fellows each from years 1 to 3 of training) was performed using the SAFE-T tool. An independent reviewer evaluated a subset of these procedures and completed the SAFE-T tool and Mayo Colonoscopy Skills Assessment Tool (MCSAT) for reliability testing. Twenty-six faculty completed 350 SAFE-T evaluations of the 15 fellows in the study. The mean SAFE-T overall score (year 1, 2.00; year 2, 3.84; year 3, 4.28) differentiated each sequential fellow year of training (P < .0001). The mean SAFE-T overall score decreased with increasing case complexity score, with straightforward cases compared with average cases (4.07 vs 3.50, P < .0001), and average cases compared with challenging cases (3.50 vs 3.08, P = .0134). In dual-observed procedures, the SAFE-T tool showed excellent inter-rater reliability with a kappa agreement statistic of 0.898 (P < .0001). Correlation of the SAFE-T overall score with the MCSAT overall hands-on and individual motor scores was excellent (each r > 0.90, P < .0001). We developed and validated the SAFE-T assessment tool, a concise and web-based means of assessing real-time gastroenterology fellow performance in colonoscopy. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Incidence and management of colonoscopic perforations: 8 years’ experience

    PubMed Central

    Tulchinsky, Hagit; Madhala-Givon, Osnat; Wasserberg, Nir; Lelcuk, Shlomo; Niv, Yaron

    2006-01-01

    AIM: To review the experience of a major medical teaching center with diagnostic and therapeutic colonoscopies and to assess the incidence and management of related colonic perforations. METHODS: All colonoscopies performed between January 1994 and December 2001 were studied. Data on patients, colonoscopic reports and procedure-related complications were collected from the departmental computerized database. The medical records of the patients with post procedural colonic perforation were reviewed. RESULTS: A total of 12 067 colonoscopies were performed during the 8 years of the study. Seven colonoscopic perforations (4 females, 3 males) were diagnosed (0.058%). Five occurred during diagnostic and two during therapeutic colonoscopy. Six were suspected during or immediately after colonoscopy. All except one had signs of diffuse tenderness and underwent immediate operation with primary repair done in 4 patients. No deaths were reported. CONCLUSION: Perforation rate during colonoscopy is low. Nevertheless, it is a serious complication and its early recognition and treatment are essential to optimize outcome. In patients with diffuse peritonitis early operative intervention makes primary repair a safe option. PMID:16830377

  12. Accuracy of colonoscopy in localizing colonic cancer.

    PubMed

    Stanciu, C; Trifan, Anca; Khder, Saad Alla

    2007-01-01

    It is important to establish the precise localization of colonic cancer preoperatively; while colonoscopy is regarded as the diagnostic gold standard for colorectal cancer, its ability to localize the tumor is less reliable. To define the accuracy of colonoscopy in identifying the location of colonic cancer. All of the patients who had a colorectal cancer diagnosed by colonoscopy at the Institute of Gastroenterology and Hepatology, Iaşi and subsequently received a surgical intervention at three teaching hospitals in Iaşi, between January 2001 and December 2005, were included in this study. Endoscopic records and operative notes were carefully reviewed, and tumor localization was recorded. There were 161 patients (89 men, 72 women, aged 61.3 +/- 12.8 years) who underwent conventional surgery for colon cancer detected by colonoscopy during the study period. Twenty-two patients (13.66%) had erroneous colonoscopic localization of the tumors. The overall accuracy of preoperative colonoscopic localization was 87.58%. Colonoscopy is an accurate, reliable method for locating colon cancer, although additional techniques (i.e., endoscopic tattooing) should be performed at least for small lesions.

  13. Views of supervisors of colonoscopy training on quality issues for the national bowel cancer screening program in Australia.

    PubMed

    Pentti, Marita; Muller, Jennifer; Janda, Monika; Newman, Beth

    2009-02-01

    To describe the views of supervisors of colonoscopy training in regard to colonoscopy training capacity and quality in Australia. Anonymous postal surveys from March to May 2007 were posted to 127 colonoscopy training supervisors (30.2% estimated response rate). The surveys queried colonoscopy training capacity and quality, supervisors' views and opinions on innovative approaches to colonoscopy training, number of colonoscopies and time required by trainees to gain competence in colonoscopy. Approximately 50% of trainers agreed and 27% disagreed that current numbers of training places were adequate to maintain a skilled colonoscopy workforce in preparation for the National Bowel Cancer Screening Program (NBCSP). A collaborative approach with the private sector was seen as beneficial by 65%. Non-gastroenterologists (non-GEs) were more likely than gastroenterologists (GEs) to be of the opinion that simulators are beneficial for colonoscopy training (chi(2)-test = 5.55, P = 0.026). The majority of trainers did not support training either nurses (73%) or general practitioners (GPs) in colonoscopy (71%). Approximately 60% of trainers considered that the current requirements for recognition of training in colonoscopy could be insufficient for trainees to gain competence and 80% of those indicated that > or = 200 colonoscopies were needed. Colonoscopy training in Australia has traditionally followed the apprenticeship model. Projected increases in demand for colonoscopy with the introduction of the NBCSP may require additional training places and new and innovative approaches to training in order to ensure the provision of high-quality colonoscopy services under the NBCSP.

  14. Patients with History of Colonoscopy Are Less Likely to Achieve High Quality Preparation After Implementing Split-Dose Bowel Preparation.

    PubMed

    Madhoun, M F; Bitar, H; Parava, P; Bashir, M H; Zia, H

    2017-01-01

    Anecdotally, we observed that patients who had previous colonoscopies were less likely to follow newly implemented split-dose bowel preparation (SDBP) instructions. We investigated whether the indication for colonoscopy is an independent factor for achieving high quality bowel preparation among patients asked to follow SDBP. We performed a retrospective study of data from 1478 patients who received outpatient colonoscopies in 2014 (the year of SDBP implementation) at our Veterans Affairs Medical Center. We collected information related to demographics and factors known to affect bowel preparations. Reasons for colonoscopy were dichotomized into surveillance (previous colonoscopy) vs. non-surveillance (positive occult blood test or screening). Bowel preparation quality was scored using the Boston Bowel Preparation Scale (BBPS), and was categorized as either excellent vs. not excellent (BBPS≥7 vs. BBPS<7), or adequate vs. inadequate (BBPS≥6 vs. BBPS<6). Bowel preparation quality was excellent in 60% of colonoscopies and adequate in 84% of colonoscopies. Thirty-six percent (535) were surveillance colonoscopies. In multivariate logistic regression analysis, more patients in the non-surveillance group achieved excellent (OR 0.8 ; 95% CI [0.7-0.8], P <0.0001) and adequate (OR 0.8 ; 95% CI [0.7-0.9], P <0.006) bowel preparation than did patients in the surveillance group. Patients with a prior colonoscopy might not follow the split-dose bowel preparation instructions. Educational interventions emphasizing the benefits of SDBP in this group of patients may help ensure compliance and prevent the habitual use of day-before preparations. © Acta Gastro-Enterologica Belgica.

  15. Diverticular disease at colonoscopy in Lagos State, Nigeria.

    PubMed

    Oluyemi, Aderemi; Odeghe, Emuobor

    2016-01-01

    The upsurge in the reported cases of diverticular disease (DD) has led to a re-appraisal of the earlier held views that it was a rare entity in Nigeria. The advent of colonoscopy has contributed in no small way to this change. We sought to determine the clinical characteristics, indications for colonoscopy, and intra-procedural findings among these patients. A retrospective cross-sectional study was carried out on the colonoscopy records from four private endoscopy units based in Lagos State, Nigeria. The records were drawn from a 5-year period (August 2010 to July 2015). The endoscopy logs and reports were reviewed, and the bio data, indications, and colonoscopy findings were gleaned. A total of 265 colonoscopies were carried out in the stated period. Of these, 28 (10.6%) had DD. Of the patients with DD, 5 (17.9%) were females while 23 (82.1%) were males. Their ages ranged from 46 to 94 years (mean = 68.2 ± 11 years). Fifteen patients had been referred for the procedure on account of hematochezia alone (15 = 53.6%). Other reasons for referral included abdominal pain alone (2 = 7%), hematochezia plus abdominal pain (5 = 17.9%), and change in bowel habits (3 = 10.8%). Ten (35%) patients had pan-colonic involvement. Regional disease involved the right side alone in only one case (3.5%) while the other combinations of sites are as follows; 6 (21.4%) in the sigmoid colon alone, 2 (7%) in the descending colon alone, 5 (17.9%) in the sigmoid-descending colon, 4 (14.3%) in the sigmoid-descending-transverse colon, thus the sigmoid colon was involved in 25 (89.3%) cases. Five cases (17.9%) had endoscopic features suggestive of diverticulitis. DD should no longer be regarded as a rare problem in the Nigerian patient. The study findings support the notion of higher prevalence among the elderly, in males, and of sigmoid colon involvement.

  16. Pioneering Annual Colorectal Cancer Screening and Treatment Targeting Low Income Communities in Malaysia (20102015).

    PubMed

    Tze, Christina Ng Van; Fitzgerald, Henry; Qureshi, Akhtar; Tan, Huck Joo; Low, May Lee

    2016-01-01

    The aim of this study was to assess the rate of uptake of a customised annual Colorectal Cancer Awareness, Screening and Treatment Project (CCASTP) using faecal immunohistochemical test (FIT) kits in low income communities in Malaysia. The immediate objectives were (1) to evaluate the level of adherence of CRC screening among lowincome groups, (2) to assess the knowledge and awareness of the screened population and (3) to assess the accuracy of FIT kits. A total of 1,581 FIT kits were distributed between years 2010 to 2015 to healthy asymptomatic participants of the annual CCASTP organized by Empowered the Cancer Advocacy Society of Malaysia. Data for sociodemographic characteristics, critical health and lifestyle information of the registered subjects were collected. Findings for use of the FIT kits were collected when they were returned for stool analyses. Those testingd positive were invited to undergo a colonoscopy examination. A total of 1,436 (90.8%) of the subjects retuned the FITkits, showing high compliance. Among the 129 subjects with positive FIT results, 92 (71.3%) underwent colonoscopy. Six cases (6.5%) of CRC were found. Based on the data collected, the level of awareness of stool examination and knowledge about CRC was poor amongst the participants. Gender, age group, ethnicity and risk factors (i.e. smoking, lack of exercise and low consumption of fresh fruits) were associated with positive FITkit results. In conclusion, CRC screening can be performed in the community with a single FITkit. Although CRC knowledge and awareness is poor in lowincome communities, the average return rate of the FIT kits and rate of colonoscopy examination were 91.2% and 70.3%, respectively.

  17. The development of a virtual reality training curriculum for colonoscopy.

    PubMed

    Sugden, Colin; Aggarwal, Rajesh; Banerjee, Amrita; Haycock, Adam; Thomas-Gibson, Siwan; Williams, Christopher B; Darzi, Ara

    2012-07-01

    The development of a structured virtual reality (VR) training curriculum for colonoscopy using high-fidelity simulation. Colonoscopy requires detailed knowledge and technical skill. Changes to working practices in recent times have reduced the availability of traditional training opportunities. Much might, therefore, be achieved by applying novel technologies such as VR simulation to colonoscopy. Scientifically developed device-specific curricula aim to maximize the yield of laboratory-based training by focusing on validated modules and linking progression to the attainment of benchmarked proficiency criteria. Fifty participants comprised of 30 novices (<10 colonoscopies), 10 intermediates (100 to 500 colonoscopies), and 10 experienced (>500 colonoscopies) colonoscopists were recruited to participate. Surrogates of proficiency, such as number of procedures undertaken, determined prospective allocation to 1 of 3 groups (novice, intermediate, and experienced). Construct validity and learning value (comparison between groups and within groups respectively) for each task and metric on the chosen simulator model determined suitability for inclusion in the curriculum. Eight tasks in possession of construct validity and significant learning curves were included in the curriculum: 3 abstract tasks, 4 part-procedural tasks, and 1 procedural task. The whole-procedure task was valid for 11 metrics including the following: "time taken to complete the task" (1238, 343, and 293 s; P < 0.001) and "insertion length with embedded tip" (23.8, 3.6, and 4.9 cm; P = 0.005). Learning curves consistently plateaued at or beyond the ninth attempt. Valid metrics were used to define benchmarks, derived from the performance of the experienced cohort, for each included task. A comprehensive, stratified, benchmarked, whole-procedure curriculum has been developed for a modern high-fidelity VR colonoscopy simulator.

  18. ACA-mandated elimination of cost sharing for preventive screening has had limited early impact.

    PubMed

    Mehta, Shivan J; Polsky, Daniel; Zhu, Jingsan; Lewis, James D; Kolstad, Jonathan T; Loewenstein, George; Volpp, Kevin G

    2015-07-01

    The Affordable Care Act eliminated patient cost sharing for evidence-based preventive care, yet the impact of this policy on colonoscopy and mammography rates is unclear. We examined the elimination of cost sharing among small business beneficiaries of Humana, a large national insurer. This was a retrospective interrupted time series analysis of whether the change in cost-sharing policy was associated with a change in screening utilization, using grandfathered plans as a comparison group. We compared beneficiaries in small business nongrandfathered plans that were required to eliminate cost sharing (intervention) with those in grandfathered plans that did not have to change cost sharing (control). There were 63,246 men and women aged 50 to 64 years eligible for colorectal cancer screening, and 30,802 women aged 50 to 64 years eligible for breast cancer screening. The primary outcome variables were rates of colonoscopy and mammography per person-month, with secondary analysis of colonoscopy rates coded as preventive only. There was no significant change in the level or slope of colonoscopy and mammography utilization for intervention plans relative to the control plans. There was also no significant relevant change among those colonoscopies coded as preventive. The results suggest that the implementation of the policy is not having its intended effects, as cost sharing rates for colonoscopy and mammography did not change substantially, and utilization of colonoscopy and mammography changed little, following this new policy approach.

  19. Ketamine versus alfentanil combined with propofol for sedation in colonoscopy procedures: a randomized prospective study.

    PubMed

    Türk, Hacer Şebnem; Aydoğmuş, Meltem; Ünsal, Oya; Işıl, Canan Tülay; Citgez, Bülent; Oba, Sibel; Açık, Mehmet Eren

    2014-12-01

    Different drug combinations are used for sedation in colonoscopy procedures. A ketamine-propofol (ketofol) mixture provides effective sedation and has minimal adverse effects. Alfentanil also provides anesthesia for short surgical procedures by incremental injection as an adjunct. However, no study has investigated the use of ketofol compared with an opioid-propofol combination in colonoscopic procedures. A total of 70 patients, ASA physical status I-II, scheduled to undergo elective colonoscopy, were enrolled in this prospective randomized study and allocated to two groups. After premedication, sedation induction was performed with 0.5 mg/kg ketamine +1 mg/kg propofol in Group KP, and 10 mg/kg alfentanil +1 mg/kg propofol in Group AP. Propofol was added when required. Demographic data, colonoscopy duration, recovery time, discharge time, mean arterial pressure (MAP), heart rate (HR), peripheral oxygen saturation, Ramsey Sedation Scale values, colonoscopy patients' satisfaction scores, and complications were recorded. The need for additional propofol doses was significantly higher in Group AP than in Group KP. MAP at minute 1 and 5, Ramsey Sedation Scale at minute 5, and discharge time were significantly higher in Group KP than in Group AP. Additional propofol doses and total propofol dose were significantly lower in Group KP than in Group AP. Ketofol provided better hemodynamic stability and quality of sedation compared with alfentanil-propofol combination in elective colonoscopy, and required fewer additional propofol; however, it prolonged discharge time. Both combinations can safely be used in colonoscopy sedation.

  20. Randomized, double-blind trial of CO2 versus air insufflation in children undergoing colonoscopy.

    PubMed

    Homan, Matjaž; Mahkovic, Dora; Orel, Rok; Mamula, Petar

    2016-05-01

    Studies in adults have shown that postprocedural abdominal pain is reduced with the use of carbon dioxide (CO(2)) instead of air for insufflation during colonoscopy. The aim of our study was to compare postprocedural abdominal pain and girth in children undergoing colonoscopy using CO(2) or air for insufflation. This was a prospective, randomized, double-blind study that included 76 consecutive pediatric patients undergoing colonoscopy for various indications. Patients were randomly assigned to either CO(2) or air insufflation. At 2, 4, and 24 hours after the examination, the patients' pain was assessed by using the 11-point numerical rating scale. The waist circumference was measured 10 minutes and 2 and 4 hours after colonoscopy. A significantly higher proportion of patients had no pain after colonoscopy in the CO(2) group compared with the air group (82 vs 37% at 2 hours and 95% vs. 63% at 4 hours, P < .001). Mean abdominal pain scores 2 and 4 hours after the procedure were statistically significantly lower in the CO(2) group compared with the control air group (0.5 vs 2.6 at 2 hours and 0.1 vs 1.2 at 4 hours, P < .001). There was no difference in waist circumference between the 2 groups at all time intervals. The results of this randomized trial show clear benefits of CO(2) insufflation for colonoscopy in reducing postprocedural discomfort. ( NCT02407639.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  1. Visuo-spatial ability in colonoscopy simulator training.

    PubMed

    Luursema, Jan-Maarten; Buzink, Sonja N; Verwey, Willem B; Jakimowicz, J J

    2010-12-01

    Visuo-spatial ability is associated with a quality of performance in a variety of surgical and medical skills. However, visuo-spatial ability is typically assessed using Visualization tests only, which led to an incomplete understanding of the involvement of visuo-spatial ability in these skills. To remedy this situation, the current study investigated the role of a broad range of visuo-spatial factors in colonoscopy simulator training. Fifteen medical trainees (no clinical experience in colonoscopy) participated in two psycho-metric test sessions to assess four visuo-spatial ability factors. Next, participants trained flexible endoscope manipulation, and navigation to the cecum on the GI Mentor II simulator, for four sessions within 1 week. Visualization, and to a lesser degree Spatial relations were the only visuo-spatial ability factors to correlate with colonoscopy simulator performance. Visualization additionally covaried with learning rate for time on task on both simulator tasks. High Visualization ability indicated faster exercise completion. Similar to other endoscopic procedures, performance in colonoscopy is positively associated with Visualization, a visuo-spatial ability factor characterized by the ability to mentally manipulate complex visuo-spatial stimuli. The complexity of the visuo-spatial mental transformations required to successfully perform colonoscopy is likely responsible for the challenging nature of this technique, and should inform training- and assessment design. Long term training studies, as well as studies investigating the nature of visuo-spatial complexity in this domain are needed to better understand the role of visuo-spatial ability in colonoscopy, and other endoscopic techniques.

  2. Incidence and risk factors of synchronous colorectal cancer in patients with esophageal cancer: an analysis of 480 consecutive colonoscopies before surgery.

    PubMed

    Yoshida, Naoya; Tamaoki, Yuka; Baba, Yoshifumi; Sakamoto, Yasuo; Miyamoto, Yuji; Iwatsuki, Masaaki; Shono, Takashi; Miyamoto, Hideaki; Imuta, Masanori; Kurashige, Junji; Sawayama, Hiroshi; Tokunaga, Ryuma; Watanabe, Masayuki; Sasaki, Yutaka; Yamashita, Yasuyuki; Baba, Hideo

    2016-12-01

    The precise incidence rates of multiple primary colorectal cancers in esophageal cancer patients are unknown. In total, 480 consecutive patients with esophageal cancers surgically resected in the Kumamoto University Hospital received preoperative total colonoscopy for the assessment of colorectal disease between April 2005 and February 2016. We retrospectively investigated the occurrence of synchronous colorectal cancer with esophageal cancer. In addition, we examined the risk factors for the incidence of multiple primary colorectal cancers. Of the 480 patients, 14 (2.9 %) had synchronous colorectal cancers, 13 had well-differentiated tubular adenocarcinomas, and 1 had papillary adenocarcinoma. Other 14 patients had metachronous colorectal cancer. The current incidence rates of synchronous and total (both synchronous and metachronous) colorectal cancers outnumbered those in normal healthy population and those in esophageal cancer patients which previously reported by The Japan Esophageal Society. The age ≥70 years (hazard ratio 4.82, 95 % confidence interval 1.473-15.78; p = 0.009) and Brinkman index ≥800 (hazard ratio 3.47, 95 % confidence interval 1.056-11.37; p = 0.040) were the independent risk factors for the incidence of synchronous colorectal cancer. They were also the independent risk factors for the incidence of total colorectal cancer. The results of the present study suggested that pretreatment screening with total colonoscopy is meaningful for patients with esophageal cancer, because the frequency of synchronous colorectal cancer was not negligible. Particularly, in patients >70 years and with history of heavy smoking, pretreatment colonoscopy might be necessary.

  3. Aromatherapy for reducing colonoscopy related procedural anxiety and physiological parameters: a randomized controlled study.

    PubMed

    Hu, Pei-Hsin; Peng, Yen-Chun; Lin, Yu-Ting; Chang, Chi-Sen; Ou, Ming-Chiu

    2010-01-01

    Colonoscopy is generally tolerated, some patients regarding the procedure as unpleasant and painful and generally performed with the patient sedated and receiving analgesics. The effect of sedation and analgesia for colonoscopy is limited. Aromatherapy is also applied to gastrointestinal endoscopy to reduce procedural anxiety. There is lack of information about aromatherapy specific for colonoscopy. In this study, we aimed to performed a randomized controlled study to investigate the effect of aromatherapy on relieve anxiety, stress and physiological parameters of colonoscopy. A randomized controlled trail was carried out and collected in 2009 and 2010. The participants were randomized in two groups. Aromatherapy was then carried out by inhalation of Sunflower oil (control group) and Neroli oil (Experimental group). The anxiety index was evaluated by State Trait Anxiety Inventory-state (STAI-S) score before aromatherapy and after colonoscopy as well as the pain index for post-procedural by visual analogue scale (VAS). Physiological indicators, such as blood pressure (systolic and diastolic blood pressure), heart rate and respiratory rate were evaluated before and after aromatherapy. Participates in this study were 27 subjects, 13 in control group and 14 in Neroli group with average age 52.26 +/- 17.79 years. There was no significance of procedural anxiety by STAI-S score and procedural pain by VAS. The physiological parameters showed a significant lower pre- and post-procedural systolic blood pressure in Neroli group than control group. Aromatic care for colonoscopy, although with no significant effect on procedural anxiety, is an inexpensive, effective and safe pre-procedural technique that could decrease systolic blood pressure.

  4. Screening for colorectal cancer.

    PubMed

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  5. Urban–rural disparities in colorectal cancer screening: cross-sectional analysis of 1998–2005 data from the Centers for Disease Control's Behavioral Risk Factor Surveillance Study

    PubMed Central

    Cole, Allison M; Jackson, J Elizabeth; Doescher, Mark

    2012-01-01

    Despite the existence of effective screening, colorectal cancer remains the second leading cause of cancer death in the United States. Identification of disparities in colorectal cancer screening will allow for targeted interventions to achieve national goals for screening. The objective of this study was to contrast colorectal cancer screening rates in urban and rural populations in the United States. The study design comprised a cross-sectional study in the United States 1998–2005. Behavioral Risk Factor Surveillance System data from 1998 to 2005 were the method and data source. The primary outcome was self-report up-to-date colorectal cancer screening (fecal occult blood test in last 12 months, flexible sigmoidoscopy in last 5 years, or colonoscopy in last 10 years). Geographic location (urban vs. rural) was used as independent variable. Multivariate analysis controlled for demographic and health characteristics of respondents. After adjustment for demographic and health characteristics, rural residents had lower colorectal cancer screening rates (48%; 95% CI 48, 49%) as compared with urban residents (54%, 95% CI 53, 55%). Remote rural residents had the lowest screening rates overall (45%, 95% CI 43, 46%). From 1998 to 2005, rates of screening by colonoscopy or flexible sigmoidoscopy increased in both urban and rural populations. During the same time, rates of screening by fecal occult blood test decreased in urban populations and increased in rural populations. Persistent disparities in colorectal cancer screening affect rural populations. The types of screening tests used for colorectal cancer screening are different in rural and urban areas. Future research to reduce this disparity should focus on screening methods that are acceptable and feasible in rural areas. PMID:23342284

  6. Colonoscopic splenic injuries: incidence and management.

    PubMed

    Kamath, Ashwin S; Iqbal, Corey W; Sarr, Michael G; Cullinane, Daniel C; Zietlow, Scott P; Farley, David R; Sawyer, Mark D

    2009-12-01

    Splenic injuries that occur during colonoscopies are rare. There is no available incidence of this serious complication, and the literature is limited to case reports. Our study looks at single institution experience of splenic injuries during colonoscopy to define the incidence and management of this serious complication. All patients from 1980 through June 2008 sustaining a splenic injury during colonoscopy were reviewed. Four patients (of 296,248 colonoscopies) sustained a splenic injury directly from colonoscopy performed at our institution (incidence 0.001%). Three additional patients were treated at our tertiary referral center after splenic injury from colonoscopy performed elsewhere. The mean age at the time of colonoscopy was 54 years (range 40-70 years). The most common presenting symptom was abdominal pain (n = 4) with a mean decrease in hemoglobin of 6.5 g/dl (range 4.5-8.5 g/dl). Splenic injury was diagnosed by computed tomography in five patients. Six patients received a mean of 5.5 U of packed red blood cells (range 2-14 U). All patients were managed with splenectomy, six patients within 24 h of the index colonoscopy, and one patient presented more than 24 h after initial colonoscopy. There was no evidence of preexisting splenic disease in any of the patients by surgical pathology, and there were no postoperative complications or deaths. The mean duration of stay was 10 days (range 7-15 days). All patients are alive at a median follow up of 22 months (range 1-164 months). Splenic injury occurring during colonoscopy is a rare but serious complication. Patients presented with abdominal pain and a precipitous decrease in hemoglobin and have all required emergent splenectomy.

  7. Using Social Media to Characterize Public Sentiment Toward Medical Interventions Commonly Used for Cancer Screening: An Observational Study

    PubMed Central

    Metwally, Omar; Blumberg, Seth; Ladabaum, Uri

    2017-01-01

    Background Although cancer screening reduces morbidity and mortality, millions of people worldwide remain unscreened. Social media provide a unique platform to understand public sentiment toward tools that are commonly used for cancer screening. Objective The objective of our study was to examine public sentiment toward colonoscopy, mammography, and Pap smear and how this sentiment spreads by analyzing discourse on Twitter. Methods In this observational study, we classified 32,847 tweets (online postings on Twitter) related to colonoscopy, mammography, or Pap smears using a naive Bayes algorithm as containing positive, negative, or neutral sentiment. Additionally, we characterized the spread of sentiment on Twitter using an established model to study contagion. Results Colonoscopy-related tweets were more likely to express negative than positive sentiment (negative to positive ratio 1.65, 95% CI 1.51-1.80, P<.001), in contrast to the more positive sentiment expressed regarding mammography (negative to positive ratio 0.43, 95% CI 0.39-0.47, P<.001). The proportions of negative versus positive tweets about Pap smear were not significantly different (negative to positive ratio 0.95, 95% CI 0.87-1.04, P=.18). Positive and negative tweets tended to share lexical features across screening modalities. Positive tweets expressed resonance with the benefits of early detection. Fear and pain were the principal lexical features seen in negative tweets. Negative sentiment for colonoscopy and mammography spread more than positive sentiment; no correlation with sentiment and spread was seen for Pap smear. Conclusions Analysis of social media data provides a unique, quantitative framework to better understand the public’s perception of medical interventions that are commonly used for cancer screening. Given the growing use of social media, public health interventions to improve cancer screening should use the health perceptions of the population as expressed in social network postings about tests that are frequently used for cancer screening, as well as other people they may influence with such postings. PMID:28592395

  8. Potential testing of reprocessing procedures by real-time polymerase chain reaction: A multicenter study of colonoscopy devices.

    PubMed

    Valeriani, Federica; Agodi, Antonella; Casini, Beatrice; Cristina, Maria Luisa; D'Errico, Marcello Mario; Gianfranceschi, Gianluca; Liguori, Giorgio; Liguori, Renato; Mucci, Nicolina; Mura, Ida; Pasquarella, Cesira; Piana, Andrea; Sotgiu, Giovanni; Privitera, Gaetano; Protano, Carmela; Quattrocchi, Annalisa; Ripabelli, Giancarlo; Rossini, Angelo; Spagnolo, Anna Maria; Tamburro, Manuela; Tardivo, Stefano; Veronesi, Licia; Vitali, Matteo; Romano Spica, Vincenzo

    2018-02-01

    Reprocessing of endoscopes is key to preventing cross-infection after colonoscopy. Culture-based methods are recommended for monitoring, but alternative and rapid approaches are needed to improve surveillance and reduce turnover times. A molecular strategy based on detection of residual traces from gut microbiota was developed and tested using a multicenter survey. A simplified sampling and DNA extraction protocol using nylon-tipped flocked swabs was optimized. A multiplex real-time polymerase chain reaction (PCR) test was developed that targeted 6 bacteria genes that were amplified in 3 mixes. The method was validated by interlaboratory tests involving 5 reference laboratories. Colonoscopy devices (n = 111) were sampled in 10 Italian hospitals. Culture-based microbiology and metagenomic tests were performed to verify PCR data. The sampling method was easily applied in all 10 endoscopy units and the optimized DNA extraction and amplification protocol was successfully performed by all of the involved laboratories. This PCR-based method allowed identification of both contaminated (n = 59) and fully reprocessed endoscopes (n = 52) with high sensibility (98%) and specificity (98%), within 3-4 hours, in contrast to the 24-72 hours needed for a classic microbiology test. Results were confirmed by next-generation sequencing and classic microbiology. A novel approach for monitoring reprocessing of colonoscopy devices was developed and successfully applied in a multicenter survey. The general principle of tracing biological fluids through microflora DNA amplification was successfully applied and may represent a promising approach for hospital hygiene. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Gaze patterns hold key to unlocking successful search strategies and increasing polyp detection rate in colonoscopy.

    PubMed

    Lami, Mariam; Singh, Harsimrat; Dilley, James H; Ashraf, Hajra; Edmondon, Matthew; Orihuela-Espina, Felipe; Hoare, Jonathan; Darzi, Ara; Sodergren, Mikael H

    2018-02-07

    The adenoma detection rate (ADR) is an important quality indicator in colonoscopy. The aim of this study was to evaluate the changes in visual gaze patterns (VGPs) with increasing polyp detection rate (PDR), a surrogate marker of ADR. 18 endoscopists participated in the study. VGPs were measured using eye-tracking technology during the withdrawal phase of colonoscopy. VGPs were characterized using two analyses - screen and anatomy. Eye-tracking parameters were used to characterize performance, which was further substantiated using hidden Markov model (HMM) analysis. Subjects with higher PDRs spent more time viewing the outer ring of the 3 × 3 grid for both analyses (screen-based: r = 0.56, P  = 0.02; anatomy: r = 0.62, P  < 0.01). Fixation distribution to the "bottom U" of the screen in screen-based analysis was positively correlated with PDR (r = 0.62, P  = 0.01). HMM demarcated the VGPs into three PDR groups. This study defined distinct VGPs that are associated with expert behavior. These data may allow introduction of visual gaze training within structured training programs, and have implications for adoption in higher-level assessment. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Bowel Prep Quality in Patients of Low Socioeconomic Status Undergoing Screening Colonoscopy With Patient Navigation.

    PubMed

    Miller, Sarah Johanna; Itzkowitz, Steven H; Shah, Brijen; Jandorf, Lina

    2016-10-01

    The effectiveness of colonoscopy is directly affected by the quality of the patient's bowel preparation. Patients with lower socioeconomic status (SES) are at increased risk of having suboptimal bowel prep quality. Patient navigators can play a key role in clarifying bowel prep instructions. The aim of the present study was to examine the quality of bowel prep and its predictors among individuals of low SES undergoing screening colonoscopy with patient navigation. Participants (N = 607) were individuals of low SES who completed a screening colonoscopy with patient navigation. Demographic information was collected after the participants received a primary care referral for a screening colonoscopy. After the colonoscopy was completed, medical charts were reviewed to document the colonoscopists' bowel prep quality ratings. A total of 6.8% (41/607) of the sample had poor bowel prep, which significantly correlated with having a colonoscopy that did not reach the cecum. If fair preps were included, approximately 19.3% (117/607) of our cohort would be considered to have suboptimal bowel prep. Our suboptimal bowel prep rates were better than those reported from other low SES samples. © 2015 Society for Public Health Education.

  11. Results of a Community-based, Randomized Study Comparing a Clear Liquid Diet With a Low-residue Diet Using a Magnesium Citrate Preparation for Screening and Surveillance Colonoscopies.

    PubMed

    Thukral, Chandrashekhar; Tewani, Sumeet K; Lake, Adam J; Shiels, Aaron J; Geissler, Kathy; Popejoy, Sara; Stafford, Megan; Vicari, Joseph J

    2017-11-03

    Current bowel preparations for colonoscopy include a clear liquid diet (CLD) along with consumption of a laxative. This dietary restriction along with large volume bowel preparations are barriers to compliance and willingness among patients in scheduling screening examinations. The aim of our study was to compare the efficacy and tolerability of a low-volume split dose magnesium citrate bowel preparation in patients on a low-residue diet (LRD) with those on a CLD. In this single center, single blinded, randomized controlled trial, patients scheduled for outpatient colonoscopies were assigned to either a CLD or a LRD 1 day before the examination. Both groups received a split dose magnesium citrate preparation. The quality of the preparation was rated using the Boston Bowel Preparation Scale (BBPS). Patient satisfaction and side effects were evaluated using a questionnaire. We were unable to detect a significant difference in the BBPS scores between the LRD and CLD groups (P=0.581). A significantly higher percentage of patients in the LRD group rated the diet as easy compared with the CLD group (P<0.001). Satisfaction scores were significantly higher in the LRD group, compared with the CLD group (P<0.001). The side effect profiles of both arms were similar. There was no significant difference between LRD and CLD in patients using a magnesium citrate bowel preparation for screening and surveillance colonoscopies. Patient satisfaction scores were higher with a LRD compared with a CLD. We believe the LRD should be the recommended diet in patients using a standard bowel preparation for screening and surveillance colonoscopy.

  12. Colonoscopy yields fewer polyps as the day progresses despite using social influence theory to reverse the trend.

    PubMed

    Kaneshiro, Marc; Ho, Andrew; Chan, Michael; Cohen, Hartley; Spiegel, Brennan M R

    2010-12-01

    We previously reported that fewer polyps are detected by colonoscopy as the day progresses, a phenomenon that could be modified with "social influence theory" by using auditing and feedback. To measure the impact of a social influence informational poster on the relationship between time of day and colonoscopy yield. Controlled before-and-after study comparing the polyp yield and time of day relationship in a historical cohort versus a 3-month intervention period. University-based Veterans Affairs medical center. Patients undergoing outpatient screening, surveillance, or diagnostic colonoscopies. Placement of informational posters in endoscopy rooms within view of operators and nurses. The poster depicted a bar graph of the previously documented hour-by-hour decreases in polyp yield coupled with prominent text: "What Time Is It Now?" Polyp yield, including secondary end point limited to adenoma detection. We performed regression to measure the effect of start time on polyp yield. There were 477 and 301 patients in the control and intervention periods, respectively. There was a negative relationship between start time and polyp yield, including adenoma detection, for both periods (P = .001). Start time remained negatively predictive of polyp and adenoma yield after adjusting for poster exposure and confounders (P = .01). Nonrandomized study design. An informational poster did not alter the relationship between colonoscopy start time and polyp yield. This strengthens the previous finding that start time may affect polyp yield and suggests that passive use of social influence theory is inadequate to modify this effect. Shortening endoscopy shifts and active auditing with feedback may be necessary. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. Colorectal Cancer Screening

    MedlinePlus

    ... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...

  14. Associations of Mental Health and Physical Function with Colonoscopy-related Pain.

    PubMed

    Yamada, Eiji; Watanabe, Seitaro; Nakajima, Atsushi

    2017-01-01

    Objective To clarify the effects of mental health and physical function in association with colonoscopy-related pain. Methods The mental health and physical function were evaluated using the Japanese version of the SF-8 Health Survey questionnaire. Poor physical status was defined as a physical component summary (PCS) <40 and poor mental status as a mental component summary (MCS) <40. Pain was assessed using a visual analogue scale (VAS), with significant pain defined as VAS ≥70 mm and insignificant pain as VAS <70 mm. The background and colonoscopic findings were compared in patients with significant and insignificant pain. Patients This study evaluated consecutive Japanese patients who were positive on fecal occult blood tests and underwent total colonoscopy. Results Of the 100 patients, 23 had significant and 77 had insignificant colonoscopy-related pain. A multiple logistic regression analysis showed that MCS <40 [odds ratio (OR) 6.03; 95% confidence interval (CI) 1.41-25.9, p=0.0156], PCS <40 (OR 5.96; 95% CI 1.45-24.5, p=0.0133), and ≥300 seconds to reach the cecum (OR 4.13; 95% CI 1.16-14.7, p=0.0281) were independent risk factors for colonoscopy-related pain. Conclusion The mental health and physical function are important determinants of colonoscopy-related pain. Evaluating the mental health and physical function of patients prior to colonoscopy may effectively predict the degree of colonoscopy-related pain.

  15. Portable inhaled methoxyflurane is feasible and safe for colonoscopy in subjects with morbid obesity and/or obstructive sleep apnea.

    PubMed

    Nguyen, Nam Q; Toscano, Leanne; Lawrence, Matthew; Phan, Vinh-An; Singh, Rajvinder; Bampton, Peter; Fraser, Robert J; Holloway, Richard H; Schoeman, Mark N

    2015-10-01

    Colonoscopy with inhaled methoxyflurane (Penthrox) is well tolerated in unselected subjects and is not associated with respiratory depression. The aim of this prospective study was to compare the feasibility, safety, and post-procedural outcomes of portable methoxyflurane used as an analgesic agent during colonoscopy with those of anesthesia-assisted deep sedation (AADS) in subjects with morbid obesity and/or obstructive sleep apnea (OSA). The outcomes of 140 patients with morbid obesity/OSA who underwent colonoscopy with either Penthrox inhalation (n = 85; 46 men, 39 women; mean age 57.2 ± 1.1 years) or AADS (n = 55; 27 men, 28 women; mean age, 54.9 ± 1.1 years) were prospectively assessed. All Penthrox-assisted colonoscopies were successful, without any requirement for additional intravenous sedation. Compared with AADS, Penthrox was associated with a shorter total procedural time (24 ± 1 vs. 52 ± 1 minutes, P < 0.001), a lower incidence of hypotension (3 /85 vs. 23 /55, P < 0.001), and a lower incidence of respiratory desaturation (0 /85 vs. 14 /55, P < 0.001). The patients in the Penthrox group recovered more rapidly and were discharged much earlier than those in the AADS group (27 ± 2 vs. 97 ± 5 minutes, P < 0.0001). Of those who underwent colonoscopy with Penthrox, 90 % were willing to receive Penthrox again for colonoscopy. More importantly, of the patients who underwent colonoscopy with Penthrox and had had AADS for previous colonoscopy, 82 % (28 /34) preferred to receive Penthrox for future colonoscopies. Penthrox-assisted colonoscopy cost significantly less than colonoscopy with AADS ($ 332 vs. $ 725, P < 0.001), with a cost saving of approximately $ 400 for each additional complication avoided. Compared with AADS, Penthrox is highly feasible and safe in patients with morbid obesity/OSA undergoing colonoscopy and is associated with fewer cardiorespiratory complications. Because of the advantages of this approach in regard to procedural time, recovery time, and cost benefit in comparison with AADS, further evaluation in a randomized trial is warranted.

  16. Cost effectiveness and projected national impact of colorectal cancer screening in France.

    PubMed

    Hassan, C; Benamouzig, R; Spada, C; Ponchon, T; Zullo, A; Saurin, J C; Costamagna, G

    2011-09-01

    Colorectal cancer (CRC) is a major cause of morbidity and mortality in France. Only scanty data on cost-effectiveness of CRC screening in Europe are available, generating uncertainty over its efficiency. Although immunochemical fecal tests (FIT) and guaiac-based fecal occult blood tests (g-FOBT) have been shown to be cost-effective in France, cost-effectiveness of endoscopic screening has not yet been addressed. Cost-effectiveness of screening strategies using colonoscopy, flexible sigmoidoscopy, second-generation colon capsule endoscopy (CCE), FIT and g-FOBT were compared using a Markov model. A 40 % adherence rate was assumed for all strategies. Colonoscopy costs included anesthesiologist assistance. Incremental cost-effectiveness ratios (ICERs) were calculated. Probabilistic and value-of-information analyses were used to estimate the expected benefit of future research. A third-payer perspective was adopted. In the reference case analysis, FIT repeated every year was the most cost-effective strategy, with an ICER of €48165 per life-year gained vs. FIT every 2 years, which was the next most cost-effective strategy. Although CCE every 5 years was as effective as FIT 1-year, it was not a cost-effective alternative. Colonoscopy repeated every 10 years was substantially more costly, and slightly less effective than FIT 1-year. When projecting the model outputs onto the French population, the least (g-FOBT 2-years) and most (FIT 1-year) effective strategies reduced the absolute number of annual CRC deaths from 16037 to 12916 and 11217, respectively, resulting in an annual additional cost of €26 million and €347 million, respectively. Probabilistic sensitivity analysis demonstrated that FIT 1-year was the optimal choice in 20% of the simulated scenarios, whereas sigmoidoscopy 5-years, colonoscopy, and FIT 2-years were the optimal choices in 40%, 26%, and 14%, respectively. A screening program based on FIT 1-year appeared to be the most cost-effective approach for CRC screening in France. However, a substantial uncertainty over this choice is still present. © Georg Thieme Verlag KG Stuttgart · New York.

  17. High definition plus colonoscopy combined with i-scan tone enhancement vs. high definition colonoscopy for colorectal neoplasia: A randomized trial.

    PubMed

    Hoffman, Arthur; Loth, Linn; Rey, Johannes Wilhelm; Rahman, Fareed; Goetz, Martin; Hansen, Torsten; Tresch, Achim; Niederberger, Theresa; Galle, Peter Robert; Kiesslich, Ralf

    2014-11-01

    High definition endoscopy is the accepted standard in colonoscopy. However, an important problem is missed polyps. Our objective was to assess the additional adenoma detection rate between high definition colonoscopy with tone enhancement (digital chromoendoscopy) vs. white light high definition colonoscopy. In this prospective randomized trial patients were included to undergo a tandem colonoscopy. The first exam was a white light colonoscopy with removal of all visualized polyps. The second examination was randomly assigned in a 1:1 ratio as either again white light colonoscopy (Group A) or colonoscopy with tone enhancement (Group B). Primary endpoint was the adenoma detection rate during the second withdrawal (sample size calculation - 40 per group). 67 lesions (Group A: n=34 vs. Group B: n=33) in 80 patients (mean age 61 years, male 64%) were identified on the first colonoscopy. The second colonoscopy detected 78 additional lesions: n=60 with tone enhancement vs. n=18 with white light endoscopy (p<0.001). Tone enhancement found more additional adenomas (A n=20 vs. B n=6, p=0.006) and identified significantly more missed adenomas per subject (0.5 vs. 0.15, p=0.006). High definition plus colonoscopy with tone enhancement detected more adenomas missed by white light colonoscopy. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Comparison of hand-craft feature based SVM and CNN based deep learning framework for automatic polyp classification.

    PubMed

    Younghak Shin; Balasingham, Ilangko

    2017-07-01

    Colonoscopy is a standard method for screening polyps by highly trained physicians. Miss-detected polyps in colonoscopy are potential risk factor for colorectal cancer. In this study, we investigate an automatic polyp classification framework. We aim to compare two different approaches named hand-craft feature method and convolutional neural network (CNN) based deep learning method. Combined shape and color features are used for hand craft feature extraction and support vector machine (SVM) method is adopted for classification. For CNN approach, three convolution and pooling based deep learning framework is used for classification purpose. The proposed framework is evaluated using three public polyp databases. From the experimental results, we have shown that the CNN based deep learning framework shows better classification performance than the hand-craft feature based methods. It achieves over 90% of classification accuracy, sensitivity, specificity and precision.

  19. Telephone reminder call in addition to mailing notification improved the acceptance rate of colonoscopy in patients with a positive fecal immunochemical test.

    PubMed

    Cha, Jae Myung; Lee, Joung Il; Joo, Kwang Ro; Shin, Hyun Phil; Park, Jae Jun

    2011-11-01

    Colorectal cancer (CRC) screening with a fecal immunochemical test (FIT) reduces CRC mortality; however, the acceptance rate of a colonoscopy in patients with a positive FIT was not high. The aim of this study was therefore to determine whether a telephone reminder call could increase the acceptance rate of colonoscopy in patients with a positive FIT. We performed FITs for asymptomatic participants aged 50 years or older. For patients with a positive FIT, a colonoscopy was recommended via mailing notification only (control group) or via a telephone reminder call after mailing notification (intervention group). The calls informed patients about the significance of a positive FIT and encouraged a colonoscopy following positive FITs. The FIT results were positive in 90 of 8,318 patients who received FITs. Fifty patients were advised to receive colonoscopy via mailing notification only, and 40 patients were advised via both a telephone reminder call and a mailing notification. The acceptance rate of colonoscopy was significantly higher in the intervention group than in the control group (p = 0.038). The lesion-detection rate for an advanced neoplasia was also significantly higher in the intervention group than in the control group (p = 0.046). According to multivariate logistic regression analysis, a telephone reminder was a significant determinant of colonoscopy acceptance in patients with a positive FIT (OR 4.33; 95% CI, 1.19-15.75; p = 0.026). Telephone reminder calls in addition to mailing notification improved the acceptance rate of colonoscopy in patients with a positive FIT.

  20. Randomized controlled trial of probiotics after colonoscopy.

    PubMed

    D'Souza, Basil; Slack, Timothy; Wong, Shing W; Lam, Francis; Muhlmann, Mark; Koestenbauer, Jakob; Dark, Jonathan; Newstead, Graham

    2017-09-01

    Up to 20% of patients have ongoing abdominal symptoms at day 2 and beyond following colonoscopy. It was hypothesized that some of these symptoms are related to alterations in gut microbiota secondary to bowel preparation and would improve with probiotics compared with placebo. Patients were given either a probiotic or placebo capsule in the days following colonoscopy. Colonoscopy was performed with air insufflation. The probiotic capsule contained the strains Lactobacillus acidophilus NCFM and Bifidobacterium lactis Bi-07. Patients recorded their symptoms at 1 h, 1, 2, 4, 7 and 14 days post colonoscopy and returned results once their symptoms had resolved. The primary outcomes used were the length of days to resolution of bloating, abdominal pain and altered bowel function post colonoscopy. A total of 320 patients were randomized. After loss to follow-up and withdrawal, 133 patients were analysed in the probiotic group and 126 in the placebo group. Patients having probiotic had a lower number of pain days following colonoscopy, 1.99 versus 2.78 days (P < 0.033). There was no significant difference in bloating or return to normal bowel habit days (P = 0.139 and 0.265 respectively). Subgroup analysis revealed that patients with pre-existing abdominal pain benefited from probiotics in number of pain days, 2.16 versus 4.08 (P = 0.0498). Our study has shown a significant reduction in the duration of pain days post colonoscopy in patients taking probiotic compared with placebo. No significant effect was seen in terms of return to normal bowel function or bloating post colonoscopy. © 2015 Royal Australasian College of Surgeons.

  1. SAFETY OF MANNITOL USE IN BOWEL PREPARATION: a prospective assessment of intestinal methane (CH4) levels during colonoscopy after mannitol and sodium phosphate (NaP) bowel cleansing.

    PubMed

    Paulo, Gustavo Andrade de; Martins, Fernanda Prata Borges; Macedo, Erika Pereira de; Gonçalves, Manoel Ernesto Peçanha; Ferrari, Angelo Paulo

    2016-01-01

    - Adequate bowel preparation is critical for the quality of colonoscopy. Despite reported occurrence of colonic explosion due to methane and hydrogen production by bacterial fermentation during colonoscopy, gas exchange during the procedure is believed to be effective in lowering existing methane concentration, allowing for safe utilization of mannitol for bowel preparation. Thus, mannitol is widely used for bowel cleansing prior to colonoscopy, considering its low cost and effectiveness for bowel preparation. - The aim of this study was to assess the safety of mannitol for bowel preparation, when compared to sodium phosphate (NaP). - We conducted a prospective observational study in which 250 patients undergoing colonoscopy at Universidade Federal de São Paulo and Hospital Albert Einstein (São Paulo, Brazil) were approached for inclusion in the study. Patients received either mannitol (n=50) or NaP (n=200) for bowel preparation, based on physician indication. Study was conducted from August 2009 to December 2009. The main outcome of interest was presence of detectable levels of methane (CH4) during colonoscopy and reduction in such levels after gas exchange during the procedure. Methane concentrations were measured in three intestinal segments during scope introduction and withdrawal. Safety was assessed as the absence of high levels of methane, defined as 5%. Measurements were made using a multi-gas monitor (X-am 7000, Dräger Safety AG & Co. KGaA, Lübeck, Germany) connected to a plastic catheter introduced into the working channel of the colonoscope. Additional outcomes of interest included levels of O2. Methane and O2 levels are reported as ppm. Mean, difference and standard deviation of levels of gas measured in both moments were calculated and compared in both groups. Proportions of patients with detectable or high levels of methane in both groups were compared. Continuous variables were analyzed using t test and categorical variables using qui-square tests. The Ethics Committee in both study sites approved the study protocol. - Patients in both groups were similar regarding demographics, colonoscopy indication, ASA status and quality of bowel preparation. Seven (3.5%) patients in the NaP group had methane detected during introduction of the endoscope. Methane levels became undetectable during withdrawal of the scope. None of the patients in the mannitol group had detectable levels of methane. O2 levels did not differ in the groups. - This is the largest study to assess the safety of mannitol for bowel preparation, considering methane measurements. Our results indicate that mannitol use is as safe as NaP, and gas exchange was efficient in reducing methane concentrations.

  2. Prospective Trial Evaluating the Surgical Anastomosis at One-Year Colorectal Cancer Surveillance: CT Colonography Versus Optical Colonoscopy and Implications for Patient Care.

    PubMed

    Pickhardt, Perry J; Edwards, Kristin; Bruining, David H; Gollub, Marc; Kupfer, Sonja; Lubner, Sam J; Kim, David H; Ross, Eric; Keenan, Eileen; Weinberg, David S

    2017-11-01

    The aim of this study was to compare the accuracy of CT colonography versus optical colonoscopy for neoplastic involvement at the surgical anastomosis 1 year after curative-intent colorectal cancer resection. Two hundred one patients (mean age, 58.6 years; 117 men, 84 women) underwent same-day contrast-enhanced CT colonography and colonoscopy approximately 1 year (mean, 12.1 months; median, 11.9 months) after colorectal cancer resection as part of a prospective, multicenter trial. All patients enrolled were without clinical evidence of disease and considered low risk for recurrence (stage I-III). Suspected neoplastic lesions within 5 cm of the colonic anastomosis were recorded at CT colonography, with subsequent colonoscopy performed for the same, with segmental unblinding of colonography findings. Anastomotic region biopsy or polypectomy was performed at the endoscopist's discretion. None of the 201 patients had intraluminal anastomotic cancer recurrence or advanced neoplasia (or metachronous cancers). CT colonography detected extramural perianastomotic recurrence in 2 patients (1.0%); neither was detected at colonoscopy. Only 2 patients (1.0%; 2/201) were called positive at CT colonography for intraluminal anastomotic nondiminutive lesions (7- to 8-mm polyps), which were confirmed at colonoscopy but nonneoplastic at histopathology. At optical colonoscopy, the anastomosis was deemed abnormal and/or biopsied in 10.0% (20/201), yielding only 1 nondiminutive benign neoplasm (7-mm tubular adenoma). The lack of luminal cancer recurrence in our lower-risk cohort precludes assessment of sensitivity for detection, rendering the study underpowered in this regard. Potential cost savings of combined CT/CT colonography over the standard CT/colonoscopy approach were not assessed. Relevant intraluminal anastomotic pathology appears to be very uncommon 1 year after colorectal cancer resection in lower-risk cohorts. Unlike colonoscopy, diagnostic contrast-enhanced CT colonography effectively evaluates both the intra- and extraluminal aspects of the anastomosis. See Video Abstract at http://links.lww.com/DCR/A471.

  3. Adenoma detection rate is not influenced by full-day blocks, time, or modified queue position.

    PubMed

    Lurix, Einar; Hernandez, Adrian V; Thoma, Matthew; Castro, Fernando

    2012-04-01

    Recent studies have shown the adenoma detection rate (ADR) to decrease from endoscopist fatigue. Our primary objective was to evaluate the afternoon ADR in half-day versus full-day blocks. Secondary objectives were to determine whether time or complexity of prior procedures (modified queue position) influence ADR. Retrospective chart review on consecutive colonoscopies. Tertiary-care teaching hospital. This study involved all patients in our database who were over age 45 and who underwent screening and surveillance colonoscopies. ADR. A total of 3085 patients were included in the study, with an overall 31% ADR. Of these procedures, 2148 (70%) were done in the morning, and 937 (30%) were done in the afternoon (512 full-day block, 425 half-day block). By multivariate analysis, there was no difference in ADR between full-day blocks compared with afternoon-only blocks (35% vs 32%; odds ratio [OR] 1.1; 95% confidence interval [CI], 0.8-1.5; P = .2). For all afternoon colonoscopies, no decrease in ADR was noted with increasing queue position (P = .9) or time (P = .3). In addition, no difference was found comparing ADR between all afternoon colonoscopies versus morning colonoscopies (33% vs 30%; OR 1.1; CI, 1.0-1.3; P = .1). No difference was found for advanced adenomas and number of adenomas between either afternoon-only blocks versus afternoon colonoscopy in full-day blocks or morning versus all afternoon cases. Retrospective study; not all withdrawal times were recorded; trainees performed some of the procedures. Our data show that colonoscopy can be performed in full-day blocks and 30-minute slots without compromising ADR. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  4. Difference in real-time magnetic image analysis of colonic looping patterns between males and females undergoing diagnostic colonoscopy.

    PubMed

    Lam, Jacob; Wilkinson, James; Brassett, Cecilia; Brown, Jonathan

    2018-05-01

    Background and study aim  Magnetic imaging technology is of proven benefit to trainees in colonoscopy, but few studies have examined its benefits in experienced hands. There is evidence that colonoscopy is more difficult in women. We set out to investigate (i) associations between the looping configurations in the proximal and distal colon and (ii) differences in the looping prevalence between the sexes. We have examined their significance in terms of segmental intubation times and position changes required for the completion of colonoscopy. Patients and methods  We analyzed 103 consecutive synchronized luminal and magnetic image videos of diagnostic colonoscopies with normal anatomy undertaken by a single experienced operator. Results  Deep transverse loops and sigmoid N-loops were more common in females. A deep transverse loop was more likely to be present if a sigmoid alpha-loop or N-loop had formed previously. Patients with sigmoid N-loops were turned more frequently from left lateral to supine before the sigmoid-descending junction was reached, but there was no statistical correlation between completion time and looping pattern. Conclusions  This study has reexamined the prevalence of the common looping patterns encountered during colonoscopy and has identified differences between the sexes. This finding may offer an explanation as to why colonoscopy has been shown to be more difficult in females. Although a deep transverse loop following a resolved sigmoid alpha-loop was the most commonly encountered pattern, no statistical correlation between completion time and looping pattern could be shown. It is the first study to examine segmental completion times using a magnetic imager in expert hands.

  5. Effect of quality metric monitoring and colonoscopy performance.

    PubMed

    Razzak, Anthony; Smith, Dineen; Zahid, Maliha; Papachristou, Georgios; Khalid, Asif

    2016-10-01

    Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P  = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P  = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.

  6. Outcome of 24 years national surveillance in different hereditary colorectal cancer subgroups leading to more individualised surveillance.

    PubMed

    Lindberg, Lars Joachim; Ladelund, Steen; Frederiksen, Birgitte Lidegaard; Smith-Hansen, Lars; Bernstein, Inge

    2017-05-01

    Individuals with hereditary non-polyposis colorectal cancer (HNPCC) have a high risk of colorectal cancer (CRC). The benefits of colonic surveillance in Lynch syndrome and Amsterdam-positive (familial CRC type X familial colorectal cancer type X (FCCTX)) families are clear; only the interval between colonoscopies is debated. The potential benefits for families not fulfilling the Amsterdam criteria are uncertain. The aim of this study was to compare the outcome of colonic surveillance in different hereditary subgroups and to evaluate the surveillance programmes. A prospective, observational study on the outcome of colonic surveillance in different hereditary subgroups based on 24 years of surveillance data from the national Danish HNPCC register. We analysed 13 444 surveillance sessions, including 8768 incidence sessions and 20 450 years of follow-up. CRC was more incident in the Lynch subgroup (2.0%) than in any other subgroup (0.0-0.4%, p<0.0001), but the incidence of advanced adenoma did not differ between the Lynch (3.6%) and non-Lynch (2.3-3.9%, p=0.28) subgroups. Non-Lynch Amsterdam-positive and Amsterdam-negative families were similar in their CRC (0.1-0.4%, p=0.072), advanced adenoma (2.3-3.3%, p=0.32) and simple adenoma (8.4-9.9%, p=0.43) incidence. In moderate-risk families, no CRC and only one advanced adenoma was found. The risk of CRC in Lynch families is considerable, despite biannual surveillance. We suggest less frequent and more individualised surveillance in non-Lynch families. Individuals from families with a strong history of CRC could be offered 5-year surveillance colonoscopies (unless findings at the preceding surveillance session indicate shorter interval) and individuals from moderate-risk families could be handled with the population-based screening programme for CRC after an initial surveillance colonoscopy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Impact of screening colonoscopy on outcomes in colorectal cancer.

    PubMed

    Matsuda, Takahisa; Ono, Akiko; Kakugawa, Yasuo; Matsumoto, Minori; Saito, Yutaka

    2015-10-01

    Colorectal cancer is one of the most common cancers in both men and women worldwide and a good candidate for screening programs. There are two modalities of colorectal cancer screening: (i) population-based screening and (ii) opportunistic screening. The first one is based on organized, well-coordinated, monitored and established programs with a systematic invitation covering the entire target population. In contrast, opportunistic screening tests are offered to people who are being examined for other reasons. Recently, a variety of colorectal cancer screening tests have become available; each country should make a choice, based on national demographics and resources, on the screening method to be used. Fecal occult blood test, especially the fecal immunochemical test, would be the best modality for decreasing colorectal cancer mortality through population-based screening. In contrast, if the aim includes the early detection of colorectal cancer and adenomas, endoscopic methods are more appropriate. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Tests to Detect Colorectal Cancer and Polyps

    MedlinePlus

    ... colonoscopy. People are usually not sedated for this test. Studies have shown that people who have regular screening ... patients receive some form of sedation during the test. Studies suggest that colonoscopy reduces deaths from colorectal cancer ...

  9. Risks of Colorectal Cancer Screening

    MedlinePlus

    ... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...

  10. Regional colorectal cancer screening program using colonoscopy on an island: a prospective Nii-jima study.

    PubMed

    Hotta, Kinichi; Matsuda, Takahisa; Kakugawa, Yasuo; Ikematsu, Hiroaki; Kobayashi, Nozomu; Kushima, Ryoji; Hozawa, Atsushi; Nakajima, Takeshi; Sakamoto, Taku; Mori, Mika; Fujii, Takahiro; Saito, Yutaka

    2017-02-13

    Colorectal cancer screening program using fecal immunochemical test had been conducted on an isolated island named Nii-jima. However, the participation rate of the program had been approximately 12%, which was lower than average level of Japan. This study aimed to evaluate the participation rate, safety and efficacy of a colorectal cancer screening program using colonoscopy on the island. Educational campaigns were actively conducted every month using information bulletins and special propaganda pamphlets. The primary recommended modality was colonoscopy, followed by fecal immunochemical test. The participants of this program were 1671 individuals aged 40–79 years (men, 819; women, 852). A total of 789 (47.2%) individuals provided consent for this screening program, and 89.2% (704/789) of participants chose colonoscopy as the primary screening procedure. The completion rate of total colonoscopy was 99.7%, and there was no complication during this program. Detection rates of invasive cancer, intramucosal cancer, advanced neoplasia and any adenoma were 0.9% (n = 6), 2.4% (n = 17), 11.8% (n = 83) and 50.0% (n = 352), respectively. The adenoma detection rate and incidence of advanced neoplasia were significantly higher in men than in women in all age groups. The colorectal cancer screening program using colonoscopy that was conducted on an island achieved considerably higher participation rate than the conventional screening program using fecal immunochemical test. Completion rate and safety of screening colonoscopy were excellent during this program.

  11. Quality indicators in pediatric colonoscopy in a low-volume center: Implications for training

    PubMed Central

    Lee, Way-Seah; Tee, Chun-Wei; Koay, Zhong-Lin; Wong, Tat-Seng; Zahraq, Fatimah; Foo, Hee-Wei; Ong, Sik-Yong; Wong, Shin-Yee; Ng, Ruey-Terng

    2018-01-01

    AIM To study implications of measuring quality indicators on training and trainees’ performance in pediatric colonoscopy in a low-volume training center. METHODS We reviewed retrospectively the performance of pediatric colonoscopies in a training center in Malaysia over 5 years (January 2010-December 2015), benchmarked against five quality indicators: appropriateness of indications, bowel preparations, cecum and ileal examination rates, and complications. The European Society of Gastrointestinal Endoscopy guideline for pediatric endoscopy and North American Society for Pediatric Gastroenterology, Hepatology and Nutrition training guidelines were used as benchmarks. RESULTS Median (± SD) age of 121 children [males = 74 (61.2%)] who had 177 colonoscopies was 7.0 (± 4.6) years. On average, 30 colonoscopies were performed each year (range: 19-58). Except for investigations of abdominal pain (21/177, 17%), indications for colonoscopies were appropriate in the remaining 83%. Bowel preparation was good in 87%. One patient (0.6%) with severe Crohn’s disease had bowel perforation. Cecum examination and ileal intubation rate was 95% and 68.1%. Ileal intubation rate was significantly higher in diagnosing or assessing inflammatory bowel disease (IBD) than non-IBD (72.9% vs 50.0% P = 0.016). Performance of four trainees was consistent throughout the study period. Average cecum and ileal examination rate among trainees were 97% and 77%. CONCLUSION Benchmarking against established guidelines helps units with a low-volume of colonoscopies to identify area for further improvement. PMID:29531465

  12. Bowel preparation for colonoscopy with magnesium sulphate and low-volume polyethylene glycol.

    PubMed

    Tepeš, Bojan; Mlakar, Dominika N; Metličar, Tanja

    2014-06-01

    Patient compliance with bowel cleansing procedures represents one of the most objectionable aspects of colonoscopy. Adverse reactions to the purgative may result in failure to complete the preparation, inadequate visualization of the colon, polyp and even carcinoma miss rate and unwillingness to attend a follow-up colonoscopy. The primary objective of the study was to evaluate the effectiveness of bowel cleansing with magnesium sulphate and low-volume polyethylene glycol (PEG) with electrolytes. The second objective was to evaluate whether bowel cleansing was better in participants scheduled for morning colonoscopies or afternoon colonoscopies. Magnesium sulphate mineral water (2 l) and 2 l of low-volume PEG and electrolytes solution were used as our bowel cleansing protocol. A total of 13 914 participants, who participated in the Slovenian colorectal cancer screening programme in the period between 2009 and 2011, were included. Excellent bowel preparation was achieved in 11 484 (82.61%) participants; 1894 (13.62%) participants had good bowel preparation, 439 (3.16%) participants had fair bowel preparation and 85 (0.61%) participants had poor bowel preparation. Better results were achieved in the afternoon colonoscopies and in younger participant groups (P<0.001). No serious side effects of bowel cleansing were reported. This is the first study to use magnesium sulphate mineral water and PEG plus electrolytes for bowel cleansing. We found excellent bowel cleansing in 82.61% participants and in more participants if colonoscopy was performed in the afternoon.

  13. Acceptability of a Salon-Based Intervention to Promote Colonoscopy Screening among African American Women

    ERIC Educational Resources Information Center

    Floyd, Tiffany D.; DuHamel, Katherine N.; Rao, Jessica; Shuk, Elyse; Jandorf, Lina

    2017-01-01

    African American women have the highest colorectal cancer incidence and mortality rates among women of any race/ethnicity in the United States. Colonoscopy screening is an efficacious procedure for the prevention and early detection of colorectal cancer, making it a promising tool in the effort to eliminate colorectal cancer disparities. Toward…

  14. CMOST: an open-source framework for the microsimulation of colorectal cancer screening strategies.

    PubMed

    Prakash, Meher K; Lang, Brian; Heinrich, Henriette; Valli, Piero V; Bauerfeind, Peter; Sonnenberg, Amnon; Beerenwinkel, Niko; Misselwitz, Benjamin

    2017-06-05

    Colorectal cancer (CRC) is a leading cause of cancer-related mortality. CRC incidence and mortality can be reduced by several screening strategies, including colonoscopy, but randomized CRC prevention trials face significant obstacles such as the need for large study populations with long follow-up. Therefore, CRC screening strategies will likely be designed and optimized based on computer simulations. Several computational microsimulation tools have been reported for estimating efficiency and cost-effectiveness of CRC prevention. However, none of these tools is publicly available. There is a need for an open source framework to answer practical questions including testing of new screening interventions and adapting findings to local conditions. We developed and implemented a new microsimulation model, Colon Modeling Open Source Tool (CMOST), for modeling the natural history of CRC, simulating the effects of CRC screening interventions, and calculating the resulting costs. CMOST facilitates automated parameter calibration against epidemiological adenoma prevalence and CRC incidence data. Predictions of CMOST were highly similar compared to a large endoscopic CRC prevention study as well as predictions of existing microsimulation models. We applied CMOST to calculate the optimal timing of a screening colonoscopy. CRC incidence and mortality are reduced most efficiently by a colonoscopy between the ages of 56 and 59; while discounted life years gained (LYG) is maximal at 49-50 years. With a dwell time of 13 years, the most cost-effective screening is at 59 years, at $17,211 discounted USD per LYG. While cost-efficiency varied according to dwell time it did not influence the optimal time point of screening interventions within the tested range. Predictions of CMOST are highly similar compared to a randomized CRC prevention trial as well as those of other microsimulation tools. This open source tool will enable health-economics analyses in for various countries, health-care scenarios and CRC prevention strategies. CMOST is freely available under the GNU General Public License at https://gitlab.com/misselwb/CMOST.

  15. Systematic follow-up after curative surgery for colorectal cancer in Norway: a population-based audit of effectiveness, costs, and compliance.

    PubMed

    Körner, Hartwig; Söreide, Kjetil; Stokkeland, Pål J; Söreide, Jon Arne

    2005-03-01

    In this study, we analyzed the Norwegian guidelines for systematic follow-up after curative colorectal cancer surgery in a large single institution. Three hundred fourteen consecutive unselected patients undergoing curative surgery for colorectal cancer between 1996 and 1999 were studied with regard to asymptomatic curable recurrence, compliance with the program, and cost. Follow-up included carcinoembryonic antigen (CEA) interval measurements, colonoscopy, ultrasonography of the liver, and radiography of the chest. In 194 (62%) of the patients, follow-up was conducted according to the Norwegian guidelines. Twenty-one patients (11%) were operated on for curable recurrence, and 18 patients (9%) were disease free after curative surgery for recurrence at evaluation. Four metachronous tumors (2%) were found. CEA interval measurement had to be made most frequently (534 tests needed) to detect one asymptomatic curable recurrence. Follow-up program did not influence cancer-specific survival. Overall compliance with the surveillance program was 66%, being lowest for colonoscopy (55%) and highest for ultrasonography of the liver (85%). The total program cost was 228,117 euro (US 280,994 dollars), translating into 20,530 euro (US 25,289 dollars) for one surviving patient after surgery for recurrence. The total diagnosis yield with regard to disease-free survival after surgery for recurrence was 9%. Compliance was moderate. Whether the continuing implementation of such program and cost are justified should be debated.

  16. USING A MULTIFACETED APPROACH TO IMPROVE THE FOLLOW-UP OF POSITIVE FECAL OCCULT BLOOD TEST RESULTS

    PubMed Central

    Singh, Hardeep; Kadiyala, Himabindu; Bhagwath, Gayathri; Shethia, Anila; El-Serag, Hashem; Walder, Annette; Velez, Maria; Petersen, Laura A.

    2010-01-01

    Background Inadequate follow-up of abnormal fecal occult blood test (FOBT) results occurs in several types of practice settings. Our institution implemented multifaceted quality improvement (QI) activities in 2004–2005 to improve follow-up of FOBT positive results. Activities addressed pre-colonoscopy referral processes and system-level factors such as electronic communication and provider education and feedback. We evaluated their effects on timeliness and appropriateness of positive FOBT follow-up and identified factors that affect colonoscopy performance. Methods Retrospective electronic medical record (EMR) review was used to determine outcomes pre- and post-QI activities in a multi-specialty ambulatory clinic of a tertiary care Veterans Affairs facility and its affiliated satellite clinics. From 1869 FOBT positive cases, 800 were randomly selected from time periods before and after QI activities. Two reviewers used a pretested standardized data collection form to determine whether colonoscopy was appropriate or indicated based on pre-determined criteria and if so, the timeliness of colonoscopy referral and performance pre- and post-QI activities. Results In cases where a colonoscopy was indicated, the proportion of patients who received a timely colonoscopy referral and performance were significantly higher post implementation (60.5% vs. 31.7%, p<0.0001 and 11.4% vs. 3.4%, p =0.0005 respectively). A significant decrease also resulted in median times to referral and performance (6 vs. 19 days p<0.0001 and 96.5 vs. 190 days p<0.0001 respectively) and in the proportion of positive FOBT test results that had received no follow-up by the time of chart review (24.3%vs. 35.9%; p=0.0045). Significant predictors of absence of the performance of an indicated colonoscopy included performance of a non-colonoscopy procedure such as barium enema or flexible sigmoidoscopy (OR=16.9; 95% CI 1.9–145.1), patient non-adherence (OR=33.9; 95% CI 17.3–66.6), not providing an appropriate provisional diagnosis on the consultation (OR= 17.9; 95% CI 11.3–28.1) and gastroenterology service not rescheduling colonoscopies after an initial cancellation (OR= 11.0; 95% CI 5.1–23.7) Conclusions Multifaceted QI activities improved rates of timely colonoscopy referral and performance in an EMR system. However, colonoscopy was not indicated in over one third of patients with positive FOBTs, raising concerns about current screening practices and the appropriate denominator used for performance measurement standards related to colon cancer screening. PMID:19293786

  17. Interval cancers in a guaiac-based colorectal cancer screening programme: Consequences on sensitivity.

    PubMed

    Blom, Johannes; Törnberg, Sven

    2017-09-01

    Objective To evaluate interval cancers in the population-based colorectal cancer screening programme of Stockholm/Gotland, Sweden. Methods From 2008, individuals aged 60-69 were invited to colorectal cancer screening using biennial guaiac-based faecal occult blood test (Hemoccult®). Interval cancers, defined as colorectal cancer among participants not diagnosed by the screening programme but registered in the Swedish cancer register, were evaluated by cross-checking the screening histories for all cancers in the region 2008-2012. Results Of 203,848 individuals from nine different birth cohorts who participated (∼60%), 4530 (2.2%) tested positive. All invited individuals were followed up for 24 months after invitation. The cancer register reported 557 colorectal cancer, 219 (39.3%) screen-detected cancers and 338 (60.7%) interval cancers, generating both test- and episode sensitivities of approximately 40% and an interval cancer-rate of 17.1/10,000 tests. Among individuals with positive tests without colorectal cancer diagnosed at work-up colonoscopy, 37 interval cancers (10.9%) occurred. There was statistically significant lower sensitivity in women, ranging 22.4-32.2%, compared with 43.2-52.0% in men. Age-group and tumour location were not strongly correlated to screen-detected cancer rates. The programme sensitivity increased by year (20.3-25.0%), with successively more colorectal cancers diagnosed within the expanding programme (11.6-16.2%). Conclusion Interval cancer is a quality indicator of a screening programme. As the interval cancer-rate determined in a well-organized population-based screening programme was actually higher than the screen-detected cancer rate, a change to a more sensitive screening test is indicated. The lower screen-detected cancers among women, and compliance and quality of work-up colonoscopies also need attention.

  18. Colorectal cancer screening with virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Ge, Yaorong; Vining, David J.; Ahn, David K.; Stelts, David R.

    1999-05-01

    Early detection and removal of colorectal polyps have been proven to reduce mortality from colorectal carcinoma (CRC), the second leading cause of cancer deaths in the United States. Unfortunately, traditional techniques for CRC examination (i.e., barium enema, sigmoidoscopy, and colonoscopy) are unsuitable for mass screening because of either low accuracy or poor public acceptance, costs, and risks. Virtual colonoscopy (VC) is a minimally invasive alternative that is based on tomographic scanning of the colon. After a patient's bowel is optimally cleansed and distended with gas, a fast tomographic scan, typically helical computed tomography (CT), of the abdomen is performed during a single breath-hold acquisition. Two-dimensional (2D) slices and three-dimensional (3D) rendered views of the colon lumen generated from the tomographic data are then examined for colorectal polyps. Recent clinical studies conducted at several institutions including ours have shown great potential for this technology to be an effective CRC screening tool. In this paper, we describe new methods to improve bowel preparation, colon lumen visualization, colon segmentation, and polyp detection. Our initial results show that VC with the new bowel preparation and imaging protocol is capable of achieving accuracy comparable to conventional colonoscopy and our new algorithms for image analysis contribute to increased accuracy and efficiency in VC examinations.

  19. Associations of Mental Health and Physical Function with Colonoscopy-related Pain

    PubMed Central

    Yamada, Eiji; Watanabe, Seitaro; Nakajima, Atsushi

    2017-01-01

    Objective To clarify the effects of mental health and physical function in association with colonoscopy-related pain. Methods The mental health and physical function were evaluated using the Japanese version of the SF-8 Health Survey questionnaire. Poor physical status was defined as a physical component summary (PCS) <40 and poor mental status as a mental component summary (MCS) <40. Pain was assessed using a visual analogue scale (VAS), with significant pain defined as VAS ≥70 mm and insignificant pain as VAS <70 mm. The background and colonoscopic findings were compared in patients with significant and insignificant pain. Patients This study evaluated consecutive Japanese patients who were positive on fecal occult blood tests and underwent total colonoscopy. Results Of the 100 patients, 23 had significant and 77 had insignificant colonoscopy-related pain. A multiple logistic regression analysis showed that MCS <40 [odds ratio (OR) 6.03; 95% confidence interval (CI) 1.41-25.9, p=0.0156], PCS <40 (OR 5.96; 95% CI 1.45-24.5, p=0.0133), and ≥300 seconds to reach the cecum (OR 4.13; 95% CI 1.16-14.7, p=0.0281) were independent risk factors for colonoscopy-related pain. Conclusion The mental health and physical function are important determinants of colonoscopy-related pain. Evaluating the mental health and physical function of patients prior to colonoscopy may effectively predict the degree of colonoscopy-related pain. PMID:28202858

  20. The Effectiveness of Short Message Service to Assure the Preparation-to-Colonoscopy Interval before Bowel Preparation for Colonoscopy

    PubMed Central

    Kim, Tae-Oh; Lee, Nae-Young; Kim, Hyoungjun; Seo, Eun Hee; Heo, Nae-Yun; Park, Seung Ha; Moon, Young-Soo

    2015-01-01

    Background/Aims. The preparation-to-colonoscopy (PC) interval is one of several important factors for the bowel preparation. Short message service (SMS) reminder from a cellular phone has been suggested to improve compliance in various medical situations. We evaluated the effectiveness of SMS reminders to assure the PC interval for colonoscopy. Methodology. This prospective randomized study was investigator blinded. In the No-SMS group, patients took the first 2 L polyethylene glycol (PEG) between 6 and 8 PM on the day before colonoscopy and the second 2 L PEG approximately 6 hours before the colonoscopy without SMS. In the SMS group, patients took first 2 L PEG in the same manner as the No-SMS group and the second 2 L PEG after receiving an SMS 6 hours before the colonoscopy. Results. The SMS group had a lower score than the No-SMS group, according to the Ottawa Bowel Preparation Scale (P < 0.001). Multivariate logistic regression analysis showed that compliance with diet instructions (odds ratio (OR) 2.109; 95% confidence interval (CI), 1.11–3.99, P = 0.022) and intervention using SMS ((OR) 2.329; 95% (CI), 1.34–4.02, P = 0.002) were the independent significant factors for satisfactory bowel preparation. Conclusions. An SMS reminder to assure PC interval improved the bowel preparation quality for colonoscopy with bowel preparation. PMID:25792978

  1. Risk of metachronous neoplasia on surveillance colonoscopy in young patients with colorectal neoplasia.

    PubMed

    Kim, Hyun Gun; Cho, Young-Seok; Cha, Jae Myung; Shin, Jeong Eun; Kim, Kyeong Ok; Yang, Hyo-Joon; Koo, Hoon Sup; Joo, Young-Eun; Boo, Sun-Jin

    2018-03-01

    Few prior reports exist that address the appropriate colonoscopy surveillance interval for individuals <50 years old. We compared the risk of metachronous neoplasia between younger (20-49 years) and older (50-54 years) cohorts. This multicenter retrospective cohort study compared the incidence of metachronous neoplasia in younger and older cohorts according to baseline risk stratification. Subjects were eligible if they underwent their first colonoscopy between June 2006 and May 2010 and had at least 1 or more surveillance colonoscopy up to June 2015. Among a total of 10,477 subjects who underwent baseline colonoscopy, 9722 were eligible after excluding 755 subjects. Of those 9722 subjects, 43% underwent surveillance colonoscopy. In the baseline high-risk adenoma group (n = 840), the 3-year risk of metachronous advanced neoplasia was 10.7% in the younger patients on screening colonoscopy and 8.9% in the older patients (P > .1). In the baseline low-risk adenoma group (n = 1869), the 5-year risk of metachronous advanced neoplasia was 4.9% in the younger patients on screening colonoscopy and 5.1% in the older patients (P > .1). Similarly, in the baseline no neoplasia group (n = 7013), the 5-year risk of metachronous advanced neoplasia was 4.1% in the younger patients on screening colonoscopy and 5.6% in the older patients (P > .1). Considering the similar risk of metachronous advanced neoplasia in younger and older individuals, we suggest a 3-year surveillance interval for high-risk adenoma and a 5-year surveillance interval for low-risk adenoma in young individuals without a strong family history. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    PubMed

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  3. Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients.

    PubMed

    Yoshikawa, Ichiro; Honda, Hidekazu; Nagata, Kaori; Kanda, Kikuo; Yamasaki, Takuji; Kume, Keiichiro; Tabaru, Akinari; Otsuki, Makoto

    2002-12-01

    Application of a new variable stiffness colonoscope (VSC) is expected to control loop formation and to lessen patient discomfort. The aim of this prospective study was to compare the efficacy of VSC with a conventional colonoscope (CC) in unsedated colonoscopy, based on the experience of examiners. Four-hundred sixty-seven patients were randomly assigned to undergo colonoscopy with either VSC or CC by an endoscopist, including experienced and less-experienced examiners. The percentages of completed procedure and time to cecal intubation were recorded. Patients were asked to rate pain on a 5-point pain score. The percentages of completed procedure with VSC and CC were 98% and 95%, respectively, by less-experienced hands, and 99% and 98%, respectively, by experienced hands. Time for cecal intubation with VSC and CC was 15.7 and 18.5 min, respectively, by less-experienced hands, and 9.8 and 10.6 min, respectively, by experienced hands. A significantly lower mean pain score was noted in VSC patients compared with CC patients, irrespective of experience of the examiner. The percent of patients rating the procedure as moderately or severely painful was significantly lower with VSC than with CC, both in less-experienced (19% vs 40%; p < 0.01) and experienced hands (15% vs 26%; p < 0.05). Our results indicated that VSC allows favorable examination compared with CC regarding completeness, time to cecal intubation, and comfort of patients undergoing unsedated colonoscopy, irrespective of the examiner's experience. These features suggest VSC as the preferred colonoscope for patients undergoing unsedated colonoscopy.

  4. The potential of imaging techniques as a screening tool for colorectal cancer: a cost-effectiveness analysis.

    PubMed

    Greuter, Marjolein J E; Berkhof, Johannes; Fijneman, Remond J A; Demirel, Erhan; Lew, Jie-Bin; Meijer, Gerrit A; Stoker, Jaap; Coupé, Veerle M H

    2016-07-01

    Imaging may be promising for colorectal cancer (CRC) screening, since it has test characteristics comparable with colonoscopy but is less invasive. We aimed to assess the potential of CT colonography (CTC) and MR colonography (MRC) in terms of (cost-effectiveness) using the Adenoma and Serrated pathway to Colorectal CAncer model. We compared several CTC and MRC strategies with 5- or 10-yearly screening intervals with no screening, 10-yearly colonoscopy screening and biennial faecal immunochemical test (FIT) screening. We assumed trial-based participation rates in the base-case analyses and varied the rates in sensitivity analyses. Incremental lifetime costs and health effects were estimated from a healthcare perspective. The health gain of CTC and MRC was similar and ranged from 0.031 to 0.048 life-year gained compared with no screening, for 2-5 screening rounds. Lifetime costs per person for MRC strategies were €60-110 higher than those for CTC strategies with an equal number of screening rounds. All imaging-based strategies were cost-effective compared with no screening. FIT screening was the dominant screening strategy, leading to most LYG and highest cost-savings. Compared with three rounds of colonoscopy screening, CTC with five rounds was found to be cost-effective in an incremental analysis of imaging strategies. Assumptions on screening participation have a major influence on the ordering of strategies in terms of costs and effects. CTC and MRC have potential for CRC screening, compared with no screening and compared with three rounds of 10-yearly colonoscopy screening. When taking FIT screening as the reference, imaging is not cost-effective. Participation is an important driver of effectiveness and cost estimates. This is the first study to assess the cost-effectiveness of MRC screening for CRC.

  5. The first 2 years of colorectal cancer screening in Ferrara, Italy.

    PubMed

    Matarese, Vincenzo G; Feo, Carlo Vittorio; Lanza, Giovanni; Fusetti, Nadia; Carpanelli, Maria Cristina; Cataldo, Serena; Cifalà, Viviana; Ferretti, Stefano; Gafà, Roberta; Marzola, Marina; Montanari, Enrica; Palmonari, Caterina; Simone, Loredana; Trevisani, Lucio; Stockbrugger, Reinhold; Gullini, Sergio

    2011-05-01

    We report on the first screening round in the District of Ferrara, a region of Emilia-Romagna, carried out between March 2005 and March 2007 to illustrate the effort of colorectal cancer (CRC) screening from administration and information to therapy and follow-up. After invitation of 38 344 persons aged 50-69 years (28.5%), 19 480 (50.8%) accepted the immunological faecal occult blood test, with 1 149 (6%) resulting positive. One thousand and one individuals (88.2%) who tested positive for immunological faecal occult blood test accepted examination by either colonoscopy (99.5%) or barium enema (0.5%). Out of 996 screenees having a colonoscopy, 231 had low-risk adenomas (23.2%) and 239 had high-risk adenomas (24%), and were treated endoscopically (96%) or surgically (4%). Ninety-one cancers were diagnosed in 9.1% of colonoscopies (Dukes stadia: A, 58.2%; B, 19.8%; C, 18.7%; D, 3.3%). Fourteen cancers (all in polyps) were treated endoscopically, and the remaining 77 were treated by surgery. One Dukes B patient and 13 of 17 Dukes C patients received adjuvant chemotherapy. Three Dukes D patients had chemotherapy only. During the 2-year study period, 87 screenees had a follow-up colonoscopy: no neoplasia was found in 35 patients initially diagnosed with cancer; low-risk adenomas were found in 31 of 52 patients with initial high-risk adenomas. In conclusion, the first CRC screening round in Ferrara was easy to organize, had a high acceptance, and detected 91 cancers (78% of which were in Dukes stages A and B, compared with only 40% in sporadic CRC in the same background population). Chemotherapy was necessary in 17 cases. This report may motivate other health authorities to initiate CRC screening campaigns.

  6. COLORECTAL CANCER PREVENTION BY AN OPTIMIZED COLONOSCOPY PROTOCOL IN ROUTINE PRACTICE

    PubMed Central

    Xirasagar, Sudha; Li, Yi-Jhen; Hurley, Thomas G.; Tsai, Meng Han; Hardin, James W.; Hurley, Deborah M.; Hebert, James R.; de Groen, Piet C.

    2014-01-01

    We conducted a retrospective cohort study to investigate the colorectal cancer (CRC) incidence and mortality prevention achievable in clinical practice with an optimized colonoscopy protocol targeting near-complete polyp clearance. The protocol consisted of: a) telephonic reinforcement of bowel preparation instructions; b) active inspection for polyps throughout insertion and circumferential withdrawal; and, c) timely updating of the protocol and documentation to incorporate the latest guidelines. Of 17,312 patients provided screening colonoscopies by 59 endoscopists in South Carolina, USA from 09/2001 through 12/2008, 997 were excluded using accepted exclusion criteria. Data on 16,315 patients were merged with the South Carolina Central Cancer Registry and Vital Records Registry data from 01/1996 – 12/2009 to identify incident CRC cases and deaths, incident lung cancers and brain cancer deaths (comparison control cancers). The standardized incidence ratios (SIR) and standardized mortality ratios (SMR) relative to South Carolina and US SEER-18 population rates were calculated. Over 78,375 person-years of observation, 18 patients developed CRC vs. 104.11 expected for an SIR of 0.17, or 83% CRC protection, the rates being 68% and 91%, respectively among the adenoma- and adenoma-free subgroups (all p<0.001). Restricting the cohort to ensure minimum 5-year follow-up (mean follow-up 6.58 years) did not change the results. The CRC mortality reduction was 89% (p<0.001; 4 CRC deaths vs. 35.95 expected). The lung cancer SIR was 0.96 (p=0.67), and brain cancer SMR was 0.92 (p=0.35). Over 80% reduction in CRC incidence and mortality is achievable in routine practice by implementing key colonoscopy principles targeting near-complete polyp clearance. PMID:25242510

  7. Surveillance of individuals at intermediate risk of colorectal cancer--the impact of new guidelines.

    PubMed

    Clark, S K; Carpenter, S; Broughton, C I M; Marks, C G

    2003-11-01

    Individuals with two first degree relatives, or one diagnosed at age < 45 years, with colorectal cancer are at sufficient risk to merit surveillance. Most undergo colonoscopy four to five yearly, starting 10 years before the youngest case. The aim of this study was to assess the impact of a proposed new surveillance protocol. We identified individuals with these risk criteria seen in our clinic from 1989 to 2001 and reviewed their notes with respect to colonoscopy. Colonoscopy (n = 295) was performed on 186 patients in accordance with current recommendations. Cancer was detected in three and adenoma in 21 individuals. Applying the proposed protocol, 123 (42%) fewer colonoscopies would have been performed. No cancers would have been missed, but in five cases a small adenoma would not have been detected. Proposed new guidelines for surveillance of those at intermediate risk reduce the burden of colonoscopy without compromising identification of significant neoplasia.

  8. [THE FAILURE MODES AND EFFECTS ANALYSIS FACILITATES A SAFE, TIME AND MONEY SAVING OPEN ACCESS COLONOSCOPY SERVICE].

    PubMed

    Gingold-Belfer, Rachel; Niv, Yaron; Horev, Nehama; Gross, Shuli; Sahar, Nadav; Dickman, Ram

    2017-04-01

    Failure modes and effects analysis (FMEA) is used for the identification of potential risks in health care processes. We used a specific FMEA - based form for direct referral for colonoscopy and assessed it for procedurerelated perforations. Ten experts in endoscopy evaluated and computed the entire referral process, modes of preparation for the endoscopic procedure, the endoscopic procedure itself and the discharge process. We used FMEA assessing for likelihood of occurrence, detection and severity and calculated the risk profile number (RPN) for each of the above points. According to the highest RPN results we designed a specific open access referral form and then compared the occurrence of colonic perforations (between 2010 and 2013) in patients who were referred through the open access arm (Group 1) to those who had a prior clinical consultation (non-open access, Group 2). Our experts in endoscopy (5 physicians and 5 nurses) identified 3 categories of failure modes that, on average, reached the highest RPNs. We identified 9,558 colonoscopies in group 1, and 12,567 in group 2. Perforations were identified in three patients from the open access group (1:3186, 0.03%) and in 10 from group 2 (1:1256, 0.07%) (p = 0.024). Direct referral for colonoscopy saved 9,558 pre-procedure consultations and the sum of $850,000. The FMEA tool-based specific referral form facilitates a safe, time and money saving open access colonoscopy service. Our form may be adopted by other gastroenterological clinics in Israel.

  9. Randomised clinical trial: low-volume bowel preparation for colonoscopy - a comparison between two different PEG-based formulations.

    PubMed

    Repici, A; Cestari, R; Annese, V; Biscaglia, G; Vitetta, E; Minelli, L; Trallori, G; Orselli, S; Andriulli, A; Hassan, C

    2012-10-01

    Low-volume bowel preparations with polyethylene glycol (PEG) have been shown to provide an equivalent cleansing with improved tolerability as compared with standard PEG bowel preparation for colonoscopy. A new iso-osmotic sulphate-free formulation of PEG-Citrate-Simethicone (PEG-CS) in combination with bisacodyl has been recently developed. To compare the quality of bowel cleansing with PEG-CS with bisacodyl vs. PEG-Ascorbate (PEG-ASC) in adult out-patients undergoing colonoscopy. Randomised, observer-blind, parallel group study in adult out-patients undergoing colonoscopy in five Italian centres. Both preparations were taken the evening before the procedure. Subjects were instructed to take 2-4 tablets of 5 mg bisacodyl at 16:00 hours and 2 L of PEG-CS at 20:00 hours or 2 L of PEG-ASC plus 1 L of additional water the day before colonoscopy. Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale (≥6 scores were considered as 'clinical success'), and mucosal visibility according to a 3-point scale. Tolerability, acceptability and compliance were also evaluated. Four hundred and eight patients were randomly allocated to PEG-CS and bisacodyl (n = 204, male patient 48%, mean age 59.1 years) or PEG-ASC (n = 204, male patient 51%, age 59.4 years). In the planned per-protocol analysis, the rate of successful preparation was 79.1% following PEG-CS with bisacodyl, and 70% following PEG-ASC (P < 0.05). Mucosal visibility was evaluated as optimal in 56.1% in the PEG-CS and bisacodyl and 46.3% in the PEG-ASC group (P < 0.05). There were no serious adverse events (AE) in each of the two experimental groups. Two subjects in the PEG-ASC group discontinued the study because of AE. Polyethylene glycol-Citrate-Simethicone in combination with bisacodyl was more effective for bowel cleansing than PEG-ASC for out-patient colonoscopy. Tolerability, safety, acceptability and compliance of the two low-volume bowel preparations were similar. © 2012 Blackwell Publishing Ltd.

  10. Serrated and adenomatous polyp detection increases with longer withdrawal time: results from the New Hampshire Colonoscopy Registry.

    PubMed

    Butterly, Lynn; Robinson, Christina M; Anderson, Joseph C; Weiss, Julia E; Goodrich, Martha; Onega, Tracy L; Amos, Christopher I; Beach, Michael L

    2014-03-01

    Detection and removal of adenomas and clinically significant serrated polyps (CSSPs) is critical to the effectiveness of colonoscopy in preventing colorectal cancer. Although longer withdrawal time has been found to increase polyp detection, this association and the use of withdrawal time as a quality indicator remains controversial. Few studies have reported on withdrawal time and serrated polyp detection. Using data from the New Hampshire Colonoscopy Registry, we examined how an endoscopist's withdrawal time in normal colonoscopies affects adenoma and serrated polyp detection. We analyzed 7,996 colonoscopies performed in 7,972 patients between 2009 and 2011 by 42 endoscopists at 14 hospitals, ambulatory surgery centers, and community practices. CSSPs were defined as sessile serrated polyps and hyperplastic polyps proximal to the sigmoid. Adenoma and CSSP detection rates were calculated based on median endoscopist withdrawal time in normal exams. Regression models were used to estimate the association of increased normal withdrawal time and polyp, adenoma, and CSSP detection. Polyp and adenoma detection rates were highest among endoscopists with 9 min median normal withdrawal time, and detection of CSSPs reached its highest levels at 8-9 min. Incident rate ratios for adenoma and CSSP detection increased with each minute of normal withdrawal time above 6 min, with maximum benefit at 9 min for adenomas (1.50, 95% confidence interval (CI) (1.21, 1.85)) and CSSPs (1.77, 95% CI (1.15, 2.72)). When modeling was used to set the minimum withdrawal time at 9 min, we predicted that adenomas and CSSPs would be detected in 302 (3.8%) and 191 (2.4%) more patients. The increase in detection was most striking for the CSSPs, with nearly a 30% relative increase. A withdrawal time of 9 min resulted in a statistically significant increase in adenoma and serrated polyp detection. Colonoscopy quality may improve with a median normal withdrawal time benchmark of 9 min.

  11. 2017 WSES guidelines for the management of iatrogenic colonoscopy perforation.

    PubMed

    de'Angelis, Nicola; Di Saverio, Salomone; Chiara, Osvaldo; Sartelli, Massimo; Martínez-Pérez, Aleix; Patrizi, Franca; Weber, Dieter G; Ansaloni, Luca; Biffl, Walter; Ben-Ishay, Offir; Bala, Miklosh; Brunetti, Francesco; Gaiani, Federica; Abdalla, Solafah; Amiot, Aurelien; Bahouth, Hany; Bianchi, Giorgio; Casanova, Daniel; Coccolini, Federico; Coimbra, Raul; de'Angelis, Gian Luigi; De Simone, Belinda; Fraga, Gustavo P; Genova, Pietro; Ivatury, Rao; Kashuk, Jeffry L; Kirkpatrick, Andrew W; Le Baleur, Yann; Machado, Fernando; Machain, Gustavo M; Maier, Ronald V; Chichom-Mefire, Alain; Memeo, Riccardo; Mesquita, Carlos; Salamea Molina, Juan Carlos; Mutignani, Massimiliano; Manzano-Núñez, Ramiro; Ordoñez, Carlos; Peitzman, Andrew B; Pereira, Bruno M; Picetti, Edoardo; Pisano, Michele; Puyana, Juan Carlos; Rizoli, Sandro; Siddiqui, Mohammed; Sobhani, Iradj; Ten Broek, Richard P; Zorcolo, Luigi; Carra, Maria Clotilde; Kluger, Yoram; Catena, Fausto

    2018-01-01

    Iatrogenic colonoscopy perforation (ICP) is a severe complication that can occur during both diagnostic and therapeutic procedures. Although 45-60% of ICPs are diagnosed by the endoscopist while performing the colonoscopy, many ICPs are not immediately recognized but are instead suspected on the basis of clinical signs and symptoms that occur after the endoscopic procedure. There are three main therapeutic options for ICPs: endoscopic repair, conservative therapy, and surgery. The therapeutic approach must vary based on the setting of the diagnosis (intra- or post-colonoscopy), the type of ICP, the characteristics and general status of the patient, the operator's level of experience, and surgical device availability. Although ICPs have been the focus of numerous publications, no guidelines have been created to standardize the management of ICPs. The aim of this article is to present the World Society of Emergency Surgery (WSES) guidelines for the management of ICP, which are intended to be used as a tool to promote global standards of care in case of ICP. These guidelines are not meant to substitute providers' clinical judgment for individual patients, and they may need to be modified based on the medical team's level of experience and the availability of local resources.

  12. Cross-sectional survey on awareness of colorectal cancer and a screening programme for primary health care professionals in Catalonia, Spain.

    PubMed

    Benito, L; García, M; Binefa, G; Mila, N; Vidal, C; Lluch, M T; Puig, M

    2016-11-01

    This study aimed to assess whether primary health care professionals have accurate information regarding colorectal cancer (CRC) screening procedures, surveillance recommendations and referral strategies. This cross-sectional descriptive study was based on a survey conducted among primary health care professionals in Barcelona, Spain. The questionnaire was used to gather information regarding CRC screening procedures as well as demographic and professional characteristics of the study subjects. A CRC and screening awareness score (ranging from 0 to 12) was created based on the survey questions. The response rate was 58.9% (206/305). The estimated mean score (standard deviation) was 8.43 (SD: 1.30). For four questions, more than 60% of the answers were incorrect: one related to risk factors, two concerning follow-up colonoscopy, and one related to surveillance. Only 30.8% of the participants believed that they were responsible for determining the appropriate surveillance intervals and for scheduling colonoscopies. Although the professionals had sufficient knowledge of CRC screening, professional knowledge of some aspects related to the major non-modifiable risk factors for the disease and surveillance colonoscopy procedures could be improved. Frequent communication with professionals is necessary to maintain updated screening-related information. Possible methods for facilitating communication could include continuous briefings, regular message reminders or educational websites. © 2016 John Wiley & Sons Ltd.

  13. Prospective study of the factors associated with poor tolerance to ambulatory colonoscopy under conscious sedation.

    PubMed

    Grilo-Bensusan, Israel; Herrera Martín, Pablo; Jiménez-Mesa, Remedios; Aguado Álvarez, Valle

    2018-04-01

    conscious sedation with benzodiazepines and opiates for colonoscopy is a widespread clinical practice. to determine the patient's tolerance to colonoscopy and identify the factors associated with lower tolerance. a prospective, single-center, descriptive study of patients undergoing ambulatory colonoscopy under conscious sedation. The pain was assessed using a visual analogue scale with a score of 0 to 100 and also qualitatively. three hundred patients with a median age of 54 years completed the study (p25-75: 45-64); 138 were men (46%). Tolerance was good in 273 cases (91%). The median value of tolerance was 13 (p25-p75: 4-33). Pain was considered as mild in 215 (71.7%), moderate in 57 (19%) and intense in 28 (9.3%). In the univariate study, greater pain was associated with females, anxiety, the indication for the procedure, the length of time and difficulty of the examination, and the doses of sedatives. In the multivariate study, both the indication (OR 2.92, 95% CI = 1.03-8.2, p < 0.05) and the difficulty of the examination (OR 4.68, 95% CI = 1.6-13.6, p < 0.01) were significant. Complications were found in 16 patients (5.3%), although all of them were insignificant. tolerance of patients undergoing ambulatory colonoscopy under conscious sedation is good in most cases and complications are infrequent and minor. A worse tolerance to the test is associated with women patients, individuals with anxiety prior to colonoscopy, indication, difficult and longer exploration and lower doses of sedatives.

  14. The effects of a designer music intervention on patients' anxiety, pain, and experience of colonoscopy: a short report on a pilot study.

    PubMed

    Martindale, Fiona; Mikocka-Walus, Antonina A; Walus, Bartlomiej P; Keage, Hannah; Andrews, Jane M

    2014-01-01

    There is a controversy on whether listening to music before or during colonoscopy reduces anxiety and pain and improves satisfaction and compliance with the procedure. This study aimed to establish whether specifically designed music significantly affects anxiety, pain, and experience associated with colonoscopy. In this semirandomized controlled study, 34 patients undergoing a colonoscopy were provided with either muted headphones (n = 17) or headphones playing the investigator-selected music (n = 17) for 10 minutes before and during colonoscopy. Anxiety, pain, sedation dose, and overall experience were measured using quantitative measures and scales. Participants' state anxiety decreased over time (P < .001). However, music did not significantly reduce anxiety (P = .441), pain scores (P = .313), or midazolam (P = .327) or fentanyl doses (P = .295). Despite these findings, 100% of the music group indicated that they would want music if they were to repeat the procedure, as compared with only 50% of those in the nonmusic group wanting to wear muted headphones. Although no significant effects of music on pain, anxiety, and sedation were found, a clear preference for music was expressed, therefore warranting further research on this subject.

  15. Technical interventions to increase adenoma detection rate in colonoscopy.

    PubMed

    Rondonotti, Emanuele; Andrealli, Alida; Amato, Arnaldo; Paggi, Silvia; Conti, Clara Benedetta; Spinzi, Giancarlo; Radaelli, Franco

    2016-12-01

    Adenoma detection rate (ADR) is the most robust colonoscopy quality metric and clinical studies have adopted it as the ideal method to assess the impact of technical interventions. Areas covered: We reviewed papers focusing on the impact of colonoscopy technical issues on ADR, including withdrawal time and technique, second evaluation of the right colon, patient positional changes, gastrointestinal assistant participation during colonoscopy, water-aided technique, optimization of bowel preparation and antispasmodic administration. Expert commentary: Overall, technical interventions are inexpensive, available worldwide and easy to implement. Some of them, such as the adoption of split dose regimen and slow scope withdrawal to allow a careful inspection, have been demonstrated to significantly improve ADR. Emerging data support the use of water-exchange colonoscopy. According to published studies, other technical interventions seem to provide only marginal benefit to ADR. Unfortunately, the available evidence has methodological limitations, such as small sample sizes, the inclusion of expert endoscopists only and the evaluation of single technical interventions. Additionally, larger studies are needed to clarify whether these interventions might have a higher benefit on low adenoma detectors and whether the implementation of a bundle of them, instead of a single technical maneuver, might have a greater impact on ADR.

  16. Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?

    PubMed Central

    Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R

    2014-01-01

    Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951

  17. Fluorescence-based endoscopic imaging of Thomsen-Friedenreich antigen to improve early detection of colorectal cancer.

    PubMed

    Sakuma, Shinji; Yu, James Y H; Quang, Timothy; Hiwatari, Ken-Ichiro; Kumagai, Hironori; Kao, Stephanie; Holt, Alex; Erskind, Jalysa; McClure, Richard; Siuta, Michael; Kitamura, Tokio; Tobita, Etsuo; Koike, Seiji; Wilson, Kevin; Richards-Kortum, Rebecca; Liu, Eric; Washington, Kay; Omary, Reed; Gore, John C; Pham, Wellington

    2015-03-01

    Thomsen-Friedenreich (TF) antigen belongs to the mucin-type tumor-associated carbohydrate antigen. Notably, TF antigen is overexpressed in colorectal cancer (CRC) but is rarely expressed in normal colonic tissue. Increased TF antigen expression is associated with tumor invasion and metastasis. In this study, we sought to validate a novel nanobeacon for imaging TF-associated CRC in a preclinical animal model. We developed and characterized the nanobeacon for use with fluorescence colonoscopy. In vivo imaging was performed on an orthotopic rat model of CRC. Both white light and fluorescence colonoscopy methods were utilized to establish the ratio-imaging index for the probe. The nanobeacon exhibited specificity for TF-associated cancer. Fluorescence colonoscopy using the probe can detect lesions at the stage which is not readily confirmed by conventional visualization methods. Further, the probe can report the dynamic change of TF expression as tumor regresses during chemotherapy. Data from this study suggests that fluorescence colonoscopy can improve early CRC detection. Supplemented by the established ratio-imaging index, the probe can be used not only for early detection, but also for reporting tumor response during chemotherapy. Furthermore, since the data obtained through in vivo imaging confirmed that the probe was not absorbed by the colonic mucosa, no registered toxicity is associated with this nanobeacon. Taken together, these data demonstrate the potential of this novel probe for imaging TF antigen as a biomarker for the early detection and prediction of the progression of CRC at the molecular level. © 2014 UICC.

  18. The impact of constructive feedback on training in gastrointestinal endoscopy using high-fidelity Virtual-Reality simulation: a randomised controlled trial.

    PubMed

    Kruglikova, Irina; Grantcharov, Teodor P; Drewes, Asbjorn M; Funch-Jensen, Peter

    2010-02-01

    Recently, virtual reality computer simulators have been used to enhance traditional endoscopy teaching. Previous studies have demonstrated construct validity of these systems and transfer of virtual skills to the operating room. However, to date no simulator-training curricula have been designed and there is very little evidence on the impact of external feedback on acquisition of endoscopic skills. The aim of the present study was to assess the impact of external feedback on the learning curves on a VR colonoscopy simulator using inexperienced trainees. 22 trainees, without colonoscopy experience were randomised to a group which received structured feedback provided by an experienced supervisor and a controlled group. All participants performed 15 repetitions of task 3 from the Introduction colonoscopy module of the Accu Touch Endoscopy simulator. Retention/transfer tests on simulator were performed 4-6 weeks after the last repetition. The proficiency levels were based on the performance of eight experienced colonoscopists. All subjects were able to complete the procedure on the simulator. There were no perforations in the feedback group versus seven in the non-feedback group. Subjects in the feedback group reached expert proficiency levels in percentage of mucosa visualised and time to reach the caecum significantly faster compared with the control group. None of the groups demonstrated significant degradation of performance in simulator retention/transfer tests. Concurrent feedback given by supervisor concur an advantage in acquisition of basic colonoscopy skills and achieving of proficiency level as compared to independent training.

  19. Expert opinions and scientific evidence for colonoscopy key performance indicators.

    PubMed

    Rees, Colin J; Bevan, Roisin; Zimmermann-Fraedrich, Katharina; Rutter, Matthew D; Rex, Douglas; Dekker, Evelien; Ponchon, Thierry; Bretthauer, Michael; Regula, Jaroslaw; Saunders, Brian; Hassan, Cesare; Bourke, Michael J; Rösch, Thomas

    2016-12-01

    Colonoscopy is a widely performed procedure with procedural volumes increasing annually throughout the world. Many procedures are now performed as part of colorectal cancer screening programmes. Colonoscopy should be of high quality and measures of this quality should be evidence based. New UK key performance indicators and quality assurance standards have been developed by a working group with consensus agreement on each standard reached. This paper reviews the scientific basis for each of the quality measures published in the UK standards. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Evaluation of a fecal immunochemistry test prior to colonoscopy for outpatients with various indications.

    PubMed

    Szilagyi, Andrew; Xue, Xiaoqing

    2017-01-01

    Stool tests can predict advanced neoplasms prior to colonoscopy. Results of immunochemical stool tests to predict findings at colonoscopy for various indications are less often reported. We compared pre-colonoscopy stool tests with findings in patients undergoing colonoscopy for different indications. Charts of patients undergoing elective or semi-urgent colonoscopy were reviewed. Comparison of adenoma detection rates and pathological findings was made between prescreened and non-prescreened, and between stool-positive and stool-negative cases. Demographics, quality of colonoscopy, and pathological findings were recorded. Odds ratios (ORs) and 95% confidence intervals (CIs) were assessed. Statistical significance was accepted at p ≤0.05. Charts of 325 patients were reviewed. Among them, stool tests were done on 144 patients: 114 were negative and 30 were positive. Findings were similar in the pretest and non-pretest groups. Detection of advanced adenomas per patient was higher in the stool-positive group compared to the stool-negative group (23.4% vs 3.5%, p =0.0016, OR =7.6 [95% CI: 2-29.3]). Five advanced adenomas (without high-grade dysplasia or adenocarcinoma) and several cases of multiple adenomas were missed in the negative group. Sensitivity and specificity for advanced polyps was 63.6% and 82.7%, respectively. The negative predictive value was 96.5%. Male gender was independently predictive of any adenoma. The stool immunochemical test best predicted advanced neoplasms and had a high negative predictive value in this small cohort. Whether this test can be applied to determine the need for colonoscopy in groups other than average risk would require more studies.

  1. A Cost Analysis of Colonoscopy using Microcosting and Time-and-motion Techniques

    PubMed Central

    Ness, Reid M.; Stiles, Renée A.; Shintani, Ayumi K.; Dittus, Robert S.

    2007-01-01

    Background The cost of an individual colonoscopy is an important determinant of the overall cost and cost-effectiveness of colorectal cancer screening. Published cost estimates vary widely and typically report institutional costs derived from gross-costing methods. Objective Perform a cost analysis of colonoscopy using micro-costing and time-and-motion techniques to determine the total societal cost of colonoscopy, which includes direct health care costs as well as direct non-health care costs and costs related to patients’ time. The design is prospective cohort. The participants were 276 contacted, eligible patients who underwent colonoscopy between July 2001 and June 2002, at either a Veterans’ Affairs Medical Center or a University Hospital in the Southeastern United States. Major results The median direct health care cost for colonoscopy was $379 (25%, 75%; $343, $433). The median direct non-health care and patient time costs were $226 (25%, 75%; $187, $323) and $274 (25%, 75%; $186, $368), respectively. The median total societal cost of colonoscopy was $923 (25%, 75%; $805, $1047). The median direct health care, direct non-health care, patient time costs, and total costs at the VA were $391, $288, $274, and $958, respectively; analogous costs at the University Hospital were $376, $189, $368, and $905, respectively. Conclusion Microcosting techniques and time-and-motion studies can produce accurate, detailed cost estimates for complex medical interventions. Cost estimates that inform health policy decisions or cost-effectiveness analyses should use total costs from the societal perspective. Societal cost estimates, which include patient and caregiver time costs, may affect colonoscopy screening rates. PMID:17665271

  2. Association of Reference Payment for Colonoscopy With Consumer Choices, Insurer Spending, and Procedural Complications.

    PubMed

    Robinson, James C; Brown, Timothy T; Whaley, Christopher; Finlayson, Emily

    2015-11-01

    Regulatory limits on consumer cost sharing permit wide variation in the prices charged for screening and diagnostic tests such as colonoscopy. Employers are experimenting with reference payment initiatives that offer full insurance coverage at low-priced facilities but require substantial cost sharing if patients select high-priced alternatives. To ascertain the effect of reference payment on facility choice, insurer spending, consumer cost sharing, and procedural complications for colonoscopy. The California Public Employees' Retirement System (CalPERS) implemented reference payment in January 2012. We obtained data on 21 644 CalPERS enrollees who underwent colonoscopy in the 3 years prior to implementation and on 13 551 patients in the 2 years after implementation. Control group data were obtained on 258 616 Anthem Blue Cross enrollees who underwent colonoscopy and who were not subject to reference payment initiatives during this 5-year period. Consumer choice of facility, price paid per procedure, total insurer spending, consumer cost sharing, and procedural complications. Choices, prices, and complications were compared for CalPERS and Anthem patients before and after implementation of reference payments, using difference-in-difference multivariable regressions to adjust for patient demographic characteristics and comorbidities, procedure indications, and geographic location. Utilization of low-priced facilities for CalPERS members increased from 68.6% in 2009 to 90.5% in 2013. After adjusting for patient demographic characteristics, comorbidities, and other factors, the implementation of reference payment increased use of low-priced facilities by 17.6 percentage points (95% CI, 11.8 to 23.4; P < .001). The mean price paid for colonoscopy for the CalPERS population increased from $1587 (95% CI, $1555-$1618) in 2009 to $1716 (95% CI, $1678-$1753) in 2011 and then decreased to $1508 (95% CI, $1469-$1548) in 2013 for patients subject to reference payment. After adjustment for other relevant factors, reference payment was responsible for a 21.0% (95% CI, -26.0% to -15.6%, P < .001) reduction in the price. Reference payment was associated with a small but statistically insignificant decline in procedural complications, from 2.1% in 2009 to 2.0% in 2013 (P = .47). In the first 2 years after implementation, CalPERS saved $7.0 million (28%) on spending for the procedure. Implementation of reference payment for colonoscopy was associated with reduced spending and no change in complications.

  3. [Effects of a Patient Educational Video Program on Bowel Preparation Prior to Colonoscopy].

    PubMed

    Cho, You Young; Kim, Hyeon Ok

    2015-10-01

    The purpose of this study was to evaluate the effects of an educational video program on bowel preparation for a colonoscopy. The study used a non-equivalent control group and non-synchronized design as a quasi-experimental research involving 101 participants undergoing bowel preparation for a colonoscopy (experimental group 51, control group 50 subjects) at W. university hospital, from Aug. 7 to Oct. 31, 2013. The control group received verbal education with an explanatory note while the experimental group received education using a video program. To measure knowledge of diet restrictions and compliance with ingesting bowel preparation solutions, a questionnaire, based on The Korean Society of Gastrointestinal Endoscopy's Guide (2003), developed by Sam-Sook You, was used after revisions and supplementation was done. To measure bowel cleanness, the 'Aronchick Bowel Preparation Scale' was adopted. Data were analyzed using the SPSS WIN 12.0 program. A higher proportion of the experimental group showed a positive change in knowledge level on diet restrictions (U=1011.50, p=.035) and ingestion of bowel preparation solutions (U=980.50, p=.019), a higher level of compliance with diet restrictions (U=638.50, p<.001), ingesting bowel preparation solutions (U=668.00, p<.001) and the level of bowel cleanness (χ²=17.00, p<.001) than the control group. The results of this study indicate that a video educational program for patients having a colonoscopy can improve knowledge, level of compliance with diet restrictions, ingestion of bowel preparation solutions, and bowel cleanness. Therefore video educational program should be used with this patient group.

  4. Higher prevalence of colon polyps in patients with Barrett’s esophagus: a case-control study

    PubMed Central

    Kumaravel, Arthi; Thota, Prashanthi N.; Lee, Hyun-Ju; Gohel, Tushar; Kanadiya, Mehulkumar K.; Lopez, Rocio; Sanaka, Madhusudhan R.

    2014-01-01

    Background and aims: Barrett’s esophagus (BE) and colorectal neoplasms share similar risk factors. Previous studies have shown variable prevalence of colon polyps in patients with BE. Our aims were to determine the prevalence and incidence of colon polyps in patients with BE, compared to those without BE. Methods: In this case-control study, the study group included patients, aged 50–75 years, with biopsy-proven BE, who underwent colonoscopy at Cleveland Clinic from January 2002 to December 2011. The control group consisted of age- and sex-matched patients who underwent colonoscopy and also an endoscopy with no evidence of BE during the same time period. Exclusion criteria for both groups were family- or personal previous history of colon cancer or polyps, prior colonic resection, inflammatory bowel disease and familial polyposis syndromes. Patient demographics, comorbidities, medication use and endoscopic and colonoscopic details were collected, including biopsy results. Results: A total of 519 patients were included in the study; 173 patients with BE in the study group and 346 without BE in the control group. Mean age at index colonoscopy was 61 ± 8 years and 75% of patients were male. On index colonoscopy, patients with BE were more likely to have polyps than controls (45% vs 32%, respectively; P = 0.003). Patients underwent between one and five colonoscopies during the follow-up. On multivariate analysis—after adjusting for age, gender and diabetes—patients with BE were 80% more likely to have any type of polyp, and 50% more likely to have adenomas found during colonoscopy. Conclusions: Patients with BE had higher prevalence and incidence of colon polyps. This has important clinical implications for screening and surveillance in BE patients. PMID:25085954

  5. The Impact of Patient Education with a Smartphone Application on the Quality of Bowel Preparation for Screening Colonoscopy.

    PubMed

    Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub

    2017-09-01

    Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p =0.007 by t -test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group.

  6. Incomplete colonoscopy: Maximizing completion rates of gastroenterologists

    PubMed Central

    Brahmania, Mayur; Park, Jei; Svarta, Sigrid; Tong, Jessica; Kwok, Ricky; Enns, Robert

    2012-01-01

    BACKGROUND Cecal intubation is one of the goals of a quality colonoscopy; however, many factors increasing the risk of incomplete colonoscopy have been implicated. The implications of missed pathology and the demand on health care resources for return colonoscopies pose a conundrum to many physicians. The optimal course of action after incomplete colonoscopy is unclear. OBJECTIVES: To assess endoscopic completion rates of previously incomplete colonoscopies, the methods used to complete them and the factors that led to the previous incomplete procedure. METHODS: All patients who previously underwent incomplete colonoscopy (2005 to 2010) and were referred to St Paul’s Hospital (Vancouver, British Columbia) were evaluated. Colonoscopies were re-attempted by a single endoscopist. Patient charts were reviewed retrospectively. RESULTS: A total of 90 patients (29 males) with a mean (± SD) age of 58±13.2 years were included in the analysis. Thirty patients (33%) had their initial colonoscopy performed by a gastroenterologist. Indications for initial colonoscopy included surveillance or screening (23%), abdominal pain (15%), gastrointestinal bleeding (29%), change in bowel habits or constitutional symptoms (18%), anemia (7%) and chronic diarrhea (8%). Reasons for incomplete colonoscopy included poor preparation (11%), pain or inadequate sedation (16%), tortuous colon (30%), diverticular disease (6%), obstructing mass (6%) and stricturing disease (10%). Reasons for incomplete procedures in the remaining 21% of patients were not reported by the referring physician. Eighty-seven (97%) colonoscopies were subsequently completed in a single attempt at the institution. Seventy-six (84%) colonoscopies were performed using routine manoeuvres, patient positioning and a variable-stiffness colonoscope (either standard or pediatric). A standard 160 or 180 series Olympus gastroscope (Olympus, Japan) was used in five patients (6%) to navigate through sigmoid diverticular disease; a pediatric colonoscope was used in six patients (7%) for similar reasons. Repeat colonoscopy on the remaining three patients (3%) failed: all three required surgery for strictures (two had obstructing malignant masses and one had a severe benign obstructing sigmoid diverticular stricture). CONCLUSION: Most patients with previous incomplete colonoscopy can undergo a successful repeat colonoscopy at a tertiary care centre with instruments that are readily available to most gastroenterologists. Other modalities for evaluation of the colon should be deferred until a second attempt is made at an expert centre. PMID:22993727

  7. Prescreening with FOBT Improves Yield and Is Cost-Effective in Colorectal Screening in the Elderly

    PubMed Central

    Changela, Kinesh; Mathur, Siddharth; Reddy, Sridhar; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury

    2014-01-01

    Background. Utilization of colonoscopy for routine colorectal cancer (CRC) screening in the elderly (patients over 75) is controversial. This study was designed to evaluate if using fecal occult blood test (FOBT) to select patients for colonoscopy can improve yield and be a cost- effective approach for the elderly. Methods. Records of 10,908 subjects who had colonoscopy during the study period were reviewed. 1496 (13.7%) were ≥75 years. In 118 of these subjects, a colonoscopy was performed to evaluate a positive FOBT. Outcomes were compared between +FOBT group (F-Group) and the asymptomatic screening group (AS-Group). The cost-effectiveness was also calculated using a median estimated standardized worldwide colonoscopy and FOBT cost (rounded to closest whole numbers) of 1000 US $ and 10 US $, respectively. Results. 118/1496 (7.9%) colonoscopies were performed for evaluation of +FOBT. 464/1496 (31%) colonoscopies were performed in AS-Group. In F-Group, high risk adenoma detection rate (HR-ADR) was 15.2%, and 11.9% had 1-2 tubular adenomas. In comparison, the control AS-Group had HR-ADR of 19.2% and 17.7% had 1-2 tubular adenomas. In the FOBT+ group, CRC was detected in 5.1% which was significantly higher than the AS-Group in which CRC was detected in 1.7% (P = 0.03). On cost-effectiveness analysis, cost per CRC detected was significantly lower, that is, 19,666 US $ in F-Group in comparison to AS-Group 58,000 US $ (P < 0.05). There were no significant differences in other parameters among groups. Conclusion. Prescreening with FOBT to select elderly for colonoscopy seems to improve the yield and can be a cost-effective CRC screening approach in this subset. The benefit in the risk benefit analysis of screening the elderly appears improved by prescreening with an inexpensive tool. PMID:25101179

  8. Prescreening with FOBT Improves Yield and Is Cost-Effective in Colorectal Screening in the Elderly.

    PubMed

    Singhal, Shashideep; Changela, Kinesh; Basi, Puneet; Mathur, Siddharth; Reddy, Sridhar; Momeni, Mojdeh; Krishnaiah, Mahesh; Anand, Sury

    2014-01-01

    Background. Utilization of colonoscopy for routine colorectal cancer (CRC) screening in the elderly (patients over 75) is controversial. This study was designed to evaluate if using fecal occult blood test (FOBT) to select patients for colonoscopy can improve yield and be a cost- effective approach for the elderly. Methods. Records of 10,908 subjects who had colonoscopy during the study period were reviewed. 1496 (13.7%) were ≥75 years. In 118 of these subjects, a colonoscopy was performed to evaluate a positive FOBT. Outcomes were compared between +FOBT group (F-Group) and the asymptomatic screening group (AS-Group). The cost-effectiveness was also calculated using a median estimated standardized worldwide colonoscopy and FOBT cost (rounded to closest whole numbers) of 1000 US $ and 10 US $, respectively. Results. 118/1496 (7.9%) colonoscopies were performed for evaluation of +FOBT. 464/1496 (31%) colonoscopies were performed in AS-Group. In F-Group, high risk adenoma detection rate (HR-ADR) was 15.2%, and 11.9% had 1-2 tubular adenomas. In comparison, the control AS-Group had HR-ADR of 19.2% and 17.7% had 1-2 tubular adenomas. In the FOBT+ group, CRC was detected in 5.1% which was significantly higher than the AS-Group in which CRC was detected in 1.7% (P = 0.03). On cost-effectiveness analysis, cost per CRC detected was significantly lower, that is, 19,666 US $ in F-Group in comparison to AS-Group 58,000 US $ (P < 0.05). There were no significant differences in other parameters among groups. Conclusion. Prescreening with FOBT to select elderly for colonoscopy seems to improve the yield and can be a cost-effective CRC screening approach in this subset. The benefit in the risk benefit analysis of screening the elderly appears improved by prescreening with an inexpensive tool.

  9. Impact of gum chewing on the quality of bowel preparation for colonoscopy: an endoscopist-blinded, randomized controlled trial.

    PubMed

    Fang, Jun; Wang, Shu-Ling; Fu, Hong-Yu; Li, Zhao-Shen; Bai, Yu

    2017-07-01

    Gum chewing can accelerate motility in the GI tract; clinical studies suggested gum chewing can reduce postoperative ileus. However, no trial has investigated the effect of gum chewing on bowel preparation for colonoscopy in addition to polyethylene glycol (PEG). The objective of this study was to investigate whether gum chewing before colonoscopy can increase the quality of bowel preparation. This was a single-center, randomized controlled trial. Consecutive patients undergoing colonoscopy were randomized to the gum group or the control group. Patients in the gum group chewed sugar-free gum every 2 hours for 20 minutes each time from the end of drinking 2 L of PEG to the beginning of colonoscopy. Patients in the control group only received 2 L of PEG before colonoscopy. The quality of bowel preparation, procedure time, adenoma detection rate, patients' tolerance, and adverse events were compared. Three hundred patients were included in the study (150 in the control group, 150 in the gum group). More than 90% of patients in both groups were satisfied with the process of bowel preparation, and the incidence of adverse events was comparable in the 2 groups (41.3% vs 46.0%, P = .42). The mean Boston Bowel Preparation Scale score was 6.2 ± 1.4 and 6.1 ± 1.2 in the control group and the gum group, respectively, and the difference between the 2 groups was not significant (P = .51). This study indicates that gum chewing does not improve the quality of bowel preparation for colonoscopy, but it can improve patients' satisfaction with the process of bowel preparation and does not have negative effects on cleanliness. (Clinical trials registration number: NCT02507037.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  10. Participation in colorectal cancer screening trials after first-time invitation: a systematic review.

    PubMed

    Khalid-de Bakker, C; Jonkers, D; Smits, K; Mesters, I; Masclee, A; Stockbrügger, R

    2011-12-01

    Colorectal cancer (CRC) screening is implemented by an increasing number of countries. Participation rates of screening programs influence the health benefit and cost-effectiveness of the applied method. The aim was to systematically review participation rate after first-time invitation for CRC screening with fecal occult blood test (FOBT), sigmoidoscopy, colonoscopy, and/or computed tomography (CT) colonography. A systematic literature search was performed prior to October 1 2009. Prospective CRC screening studies of unselected populations reporting participation rates were included. After meta-analyses, overall participation rates were found to be 47 % for FOBT, 42 % for fecal immunologic tests (FITs), 35 % for sigmoidoscopy, 41 % for sigmoidoscopy combined with FIT/FOBT, 28 % for colonoscopy, and 22 % for CT colonography. Studies comparing screening methods showed higher participation rates for less invasive methods. Studies comparing invitation methods showed higher participation rates with general practitioner involvement, a more personalized recruitment approach, and reduction of barriers that discourage participation. Knowledge of identified factors affecting CRC screening participation can be used to improve screening programs. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Readability, suitability, and health content assessment of web-based patient education materials on colorectal cancer screening.

    PubMed

    Tian, Chenlu; Champlin, Sara; Mackert, Michael; Lazard, Allison; Agrawal, Deepak

    2014-08-01

    Colorectal cancer (CRC) screening rates in the Unites States are still below target level. Web-based patient education materials are used by patients and providers to provide supplemental information on CRC screening. Low literacy levels and patient perceptions are significant barriers to screening. There are little data on the quality of these online materials from a health literacy standpoint or whether they address patients' perceptions. To evaluate the readability, suitability, and health content of web-based patient education materials on colon cancer screening. Descriptive study. Web-based patient materials. Twelve reputable and popular online patient education materials were evaluated. Readability was measured by using the Flesch-Kincaid Reading Grade Level, and suitability was determined by the Suitability Assessment of Materials, a scale that considers characteristics such as content, graphics, layout/typography, and learning stimulation. Health content was evaluated within the framework of the Health Belief Model, a behavioral model that relates patients' perceptions of susceptibility to disease, severity, and benefits and barriers to their medical decisions. Each material was scored independently by 3 reviewers. Flesch-Kincaid Reading Grade Level score, Suitability Assessment of Materials score, health content score. Readability for 10 of 12 materials surpassed the maximum recommended sixth-grade reading level. Five were 10th grade level and above. Only 1 of 12 materials received a superior suitability score; 3 materials received inadequate scores. Health content analysis revealed that only 50% of the resources discussed CRC risk in the general population and <25% specifically addressed patients at high risk, such as African Americans, smokers, patients with diabetes, and obese patients. For perceived barriers to screening, only 8.3% of resources discussed embarrassment, 25% discussed pain with colonoscopy, 25% addressed cost of colonoscopy, and none specifically mentioned the need to get colonoscopy when no symptoms are present. No material discussed the social benefits of screening. Descriptive design. Most online patient education materials for CRC screening are written beyond the recommended sixth-grade reading level, with suboptimal suitability. Health content is lacking in addressing key perceived risks, barriers, and benefits to CRC screening. Developing more appropriate and targeted patient education resources on CRC may improve patient understanding and promote screening. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Prerequisites of Colonoscopy

    PubMed Central

    Hong, Kyong Hee

    2014-01-01

    Colonoscopy is a widely accepted method for the evaluation of the colon and terminal ileum. Its diagnostic accuracy and therapeutic safety are influenced by prerequisites, including modulation of medication and bowel cleansing. Appropriate choices of sedative medication and bowel-cleansing regimen, together with diet modification, should be made based on the patient's underlying disease, age, and medication intake. Moreover, effective methods for patient education regarding bowel preparation should be considered. PMID:25133119

  13. Colonoscopy and SeHCAT for investigation of chronic diarrhea.

    PubMed

    Müller, Marcella; Willén, Roger; Stotzer, Per-Ove

    2004-01-01

    Chronic diarrhea is a common problem. Colonoscopy is the investigation of choice for diagnosis. Even a macroscopically normal mucosa on endoscopy can have abnormalities such as microscopic colitis and bile acid malabsorption (BAM). The aim of this study was to establish the value of colonoscopy with biopsies in patients with chronic diarrhea and to evaluate the additive value of a SeHCAT test for diagnosing BAM in these patients. All patients who underwent a colonoscopy between November 1999 and December 2000 were included. Patient files, colonoscopy and pathology reports and SeHCAT test results were reviewed. 205 patients were included. The most common diagnoses were diarrhea-predominant IBS (n = 76) and IBD (n = 38). 158 patients had non-bloody diarrhea, 113 (72%) of them had a macroscopically normal appearing mucosa. In 40 (35%) of these patients, a histological diagnosis could be made and microscopic colitis was the most common diagnosis (n = 27). SeHCAT test was performed in 36 patients and 15 (42%) of them had BAM. In the 47 patients with bloody diarrhea, IBD was the main diagnosis (n = 23). Colonoscopy with biopsies must be performed when investigating chronic diarrhea and BAM should be excluded.

  14. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families

    PubMed Central

    Burton-Chase, Allison M.; Hovick, Shelly R.; Peterson, Susan K.; Marani, Salma K.; Vernon, Sally W.; Amos, Christopher I.; Frazier, Marsha L.; Lynch, Patrick M.; Gritz, Ellen R.

    2013-01-01

    Purpose This study examined colonoscopy adherence and attitudes towards colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. Methods We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation-negative, 26 mutation-positive). Results While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. Conclusion Adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. PMID:23414081

  15. Virtual gastrointestinal colonoscopy in combination with large bowel endoscopy: Clinical application

    PubMed Central

    He, Qing; Rao, Ting; Guan, Yong-Song

    2014-01-01

    Although colorectal cancer (CRC) has no longer been the leading cancer killer worldwide for years with the exponential development in computed tomography (CT) or magnetic resonance imaging, and positron emission tomography/CT as well as virtual colonoscopy for early detection, the CRC related mortality is still high. The objective of CRC screening is to reduce the burden of CRC and thereby the morbidity and mortality rates of the disease. It is believed that this goal can be achieved by regularly screening the average-risk population, enabling the detection of cancer at early, curable stages, and polyps before they become cancerous. Large-scale screening with multimodality imaging approaches plays an important role in reaching that goal to detect polyps, Crohn’s disease, ulcerative colitis and CRC in early stage. This article reviews kinds of presentative imaging procedures for various screening options and updates detecting, staging and re-staging of CRC patients for determining the optimal therapeutic method and forecasting the risk of CRC recurrence and the overall prognosis. The combination use of virtual colonoscopy and conventional endoscopy, advantages and limitations of these modalities are also discussed. PMID:25320519

  16. Prevalence of flat lesions in a large screening population and their role in colonoscopy quality improvement.

    PubMed

    Reinhart, K; Bannert, C; Dunkler, D; Salzl, P; Trauner, M; Renner, F; Knoflach, P; Ferlitsch, A; Weiss, W; Ferlitsch, M

    2013-01-01

    Flat lesions pose new challenges for endoscopists, but the importance of detecting them is still controversial. Most screening studies do not survey macroscopic polyp morphology. The aims were to evaluate the percentage of flat polyp findings in a large asymptomatic adult screening population (n = 52 521), to assess the impact of shape and size on malignant transformation, and to assess the role of flat lesions regarding quality assurance in colorectal cancer prevention. Retrospective analysis of screening colonoscopies performed between 2007 and 2011 according to the Austrian "Quality management for colon cancer prevention" program. 17 771 patients with polyps were included in the study. Patients with flat polyps represented 24.2 % (n = 4293), 62.4 % (n = 11 097) were classified as having sessile and 13.4 % (n = 2381) as pedunculated polyps. Among those with flat polyps 51.4 % had adenomas (n = 2207). High grade dysplasia (HGD) was found in 2.1 % (n = 47) of flat adenomas, in 1.5 % (n = 89) of sessile adenomas and 4.7 % (n = 92) of pedunculated adenomas (P < 0.0001. The risk for containing HGD was 1.0 % for flat lesions ≤ 10 mm in size compared with 10.3 % for lesions > 10 mm, and 1.0 % for polypoid lesions ≤ 10 mm compared with 9.3 % for lesions > 10 mm (P < 0.0001). Multivariable logistic regression showed that polyp size (P < 0.0001) but not polyp shape (P = 0.438) is an independent predictor for HGD. Adenoma detection rate (ADR) correlated weakly with the flat polyp detection rate (Pearson r = 0.24). Malignant potential of polyps is mostly affected by size but not by shape. Since flat polyp detection rate only correlates poorly with ADR we do not recommend its incorporation in quality assured screening colonoscopy. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Observational methods to assess the effectiveness of screening colonoscopy in reducing right colon cancer mortality risk: SCOLAR.

    PubMed

    Goodman, Michael; Fletcher, Robert H; Doria-Rose, V Paul; Jensen, Christopher D; Zebrowski, Alexis M; Becerra, Tracy A; Quinn, Virginia P; Zauber, Ann G; Corley, Douglas A; Doubeni, Chyke A

    2015-11-01

    Screening colonoscopy's effectiveness in reducing risk of death from right colon cancers remains unclear. Methodological challenges of existing observational studies addressing this issue motivated the design of 'Effectiveness of Screening for Colorectal Cancer in Average-Risk Adults (SCOLAR)'. SCOLAR is a nested case-control study based on two large integrated health systems. This affords access to a large, well-defined historical cohort linked to integrated data on cancer outcomes, patient eligibility, test indications and important confounders. We found electronic data adequate for excluding ineligible patients (except family history), but not the detailed information needed for test indication assignment. The lessons of SCOLAR's design and implementation may be useful for future studies seeking to evaluate the effectiveness of screening tests in community settings.

  18. Using Social Media to Characterize Public Sentiment Toward Medical Interventions Commonly Used for Cancer Screening: An Observational Study.

    PubMed

    Metwally, Omar; Blumberg, Seth; Ladabaum, Uri; Sinha, Sidhartha R

    2017-06-07

    Although cancer screening reduces morbidity and mortality, millions of people worldwide remain unscreened. Social media provide a unique platform to understand public sentiment toward tools that are commonly used for cancer screening. The objective of our study was to examine public sentiment toward colonoscopy, mammography, and Pap smear and how this sentiment spreads by analyzing discourse on Twitter. In this observational study, we classified 32,847 tweets (online postings on Twitter) related to colonoscopy, mammography, or Pap smears using a naive Bayes algorithm as containing positive, negative, or neutral sentiment. Additionally, we characterized the spread of sentiment on Twitter using an established model to study contagion. Colonoscopy-related tweets were more likely to express negative than positive sentiment (negative to positive ratio 1.65, 95% CI 1.51-1.80, P<.001), in contrast to the more positive sentiment expressed regarding mammography (negative to positive ratio 0.43, 95% CI 0.39-0.47, P<.001). The proportions of negative versus positive tweets about Pap smear were not significantly different (negative to positive ratio 0.95, 95% CI 0.87-1.04, P=.18). Positive and negative tweets tended to share lexical features across screening modalities. Positive tweets expressed resonance with the benefits of early detection. Fear and pain were the principal lexical features seen in negative tweets. Negative sentiment for colonoscopy and mammography spread more than positive sentiment; no correlation with sentiment and spread was seen for Pap smear. Analysis of social media data provides a unique, quantitative framework to better understand the public's perception of medical interventions that are commonly used for cancer screening. Given the growing use of social media, public health interventions to improve cancer screening should use the health perceptions of the population as expressed in social network postings about tests that are frequently used for cancer screening, as well as other people they may influence with such postings. ©Omar Metwally, Seth Blumberg, Uri Ladabaum, Sidhartha R. Sinha. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 07.06.2017.

  19. Anatomical distribution and detection rate of colorectal neoplasms according to age in the colonoscopic screening of a Korean population.

    PubMed

    Lee, Suk-Young; Song, Wan Hee; Oh, Sang Cheul; Min, Byung-Wook; Lee, Sun Il

    2018-01-01

    Because data as a basis for the determination of proper age and modality for screening of colorectal neoplasms is lacking, we evaluated detection rates and anatomical distribution of colorectal neoplasms according to age in healthy individuals who underwent total colonoscopy for health checkup. A total of 16,100 cases that had received the colonoscopic examination from January to December in 2014 were analyzed. The total number of individuals who received total colonoscopy were divided by the number of individuals harboring colorectal adenoma to calculate the detection rate of colorectal adenoma. Individuals ≤50 years old were classified as young-age group and aged >50 were old-age group. Differences in anatomical locations of colorectal neoplasms were analyzed in the 2 age groups by chi-square test. Risk factors for colorectal adenoma in each age group were analyzed using univariate and multivariate logistic regression analyses. Detection rates of colorectal adenoma were 13.7% in all cases and 12.8% for those in their 40's. The main anatomical location of colorectal adenoma was proximal colon in both age groups (P < 0.001). Hyperplastic polyp was mainly distributed to the distal colon in both age groups (P < 0.001). Distal colon was the major site for colorectal cancer in the old-age group (P = 0.001). Proximal location of neoplasms was a risk factor for colorectal adenoma in both age groups with multivariate analysis. These data could be the bases for earlier initiation of screening for colorectal neoplasms with total colonoscopy to detect clinically significant colorectal polyps.

  20. A Randomized Trial Comparing High Definition Colonoscopy Alone With High Definition Dye Spraying and Electronic Virtual Chromoendoscopy for Detection of Colonic Neoplastic Lesions During IBD Surveillance Colonoscopy.

    PubMed

    Iacucci, Marietta; Kaplan, Gilaad G; Panaccione, Remo; Akinola, Oluseyi; Lethebe, Brendan Cord; Lowerison, Mark; Leung, Yvette; Novak, Kerri L; Seow, Cynthia H; Urbanski, Stefan; Minoo, Parham; Gui, Xianyong; Ghosh, Subrata

    2018-02-01

    Dye spraying chromoendoscopy (DCE) is recommended for the detection of colonic neoplastic lesions in inflammatory bowel disease (IBD). The majority of neoplastic lesions are visible endoscopically and therefore targeted biopsies are appropriate for surveillance colonoscopy. To compare three different techniques for surveillance colonoscopy to detect colonic neoplastic lesions in IBD patients: high definition (HD), (DCE), or virtual chromoendoscopy (VCE) using iSCAN image enhanced colonoscopy. A randomized non-inferiority trial was conducted to determine the detection rates of neoplastic lesions in IBD patients with longstanding colitis. Patients with inactive disease were enrolled into three arms of the study. Endoscopic neoplastic lesions were classified by the Paris classification and Kudo pit pattern, then histologically classified by the Vienna classification. A total of 270 patients (55% men; age range 20-77 years, median age 49 years) were assessed by HD (n=90), VCE (n=90), or DCE (n=90). Neoplastic lesion detection rates in the VCE arm was non-inferior to the DCE arm. HD was non-inferior to either DCE or VCE for detection of all neoplastic lesions. In the lesions detected, location at right colon and the Kudo pit pattern were predictive of neoplastic lesions (OR 6.52 (1.98-22.5 and OR 21.50 (8.65-60.10), respectively). In this randomized trial, VCE or HD-WLE is not inferior to dye spraying colonoscopy for detection of colonic neoplastic lesions during surveillance colonoscopy. In fact, in this study HD-WLE alone was sufficient for detection of dysplasia, adenocarcinoma or all neoplastic lesions.

  1. Epi proColon® 2.0 CE: A Blood-Based Screening Test for Colorectal Cancer.

    PubMed

    Lamb, Yvette N; Dhillon, Sohita

    2017-04-01

    Epi proColon ® 2.0 CE is a blood-based test designed to aid in the early detection of colorectal cancer. The test comprises a qualitative assay for the polymerase chain reaction (PCR) detection of methylated Septin9 DNA, the presence of which is associated with colorectal cancer: however, positive results should be verified by colonoscopy or sigmoidoscopy. Epi proColon ® 2.0 CE discriminated between patients with colorectal cancer and healthy controls with high clinical sensitivity and specificity in pivotal case-control studies. The sensitivity of the test did not appear to be affected by the tumour location or by patient age or gender. In addition, limited data suggest that Epi proColon ® 2.0 CE discriminated between patients with colorectal cancer and healthy controls with higher sensitivity and generally similar specificity to that of the faecal immunochemical test, and with higher sensitivity and specificity to that of the guaiac-based faecal occult blood test (statistical data not available). In an observational study, most patients who refused colonoscopy for screening accepted a non-invasive test option as an alternative, and preferred Epi proColon ® 2.0 CE over a stool-based test. Large prospective trials of Epi proColon ® 2.0 CE in a screening setting will be required to further elucidate the cost-effectiveness of the test. Nevertheless, currently available data suggests that Epi proColon ® 2.0 CE has the potential to be a sensitive and convenient screening option for patients refusing screening by colonoscopy.

  2. The discriminatory capability of existing scores to predict advanced colorectal neoplasia: a prospective colonoscopy study of 5,899 screening participants.

    PubMed

    Wong, Martin C S; Ching, Jessica Y L; Ng, Simpson; Lam, Thomas Y T; Luk, Arthur K C; Wong, Sunny H; Ng, Siew C; Ng, Simon S M; Wu, Justin C Y; Chan, Francis K L; Sung, Joseph J Y

    2016-02-03

    We evaluated the performance of seven existing risk scoring systems in predicting advanced colorectal neoplasia in an asymptomatic Chinese cohort. We prospectively recruited 5,899 Chinese subjects aged 50-70 years in a colonoscopy screening programme(2008-2014). Scoring systems under evaluation included two scoring tools from the US; one each from Spain, Germany, and Poland; the Korean Colorectal Screening(KCS) scores; and the modified Asia Pacific Colorectal Screening(APCS) scores. The c-statistics, sensitivity, specificity, positive predictive values(PPVs), and negative predictive values(NPVs) of these systems were evaluated. The resources required were estimated based on the Number Needed to Screen(NNS) and the Number Needed to Refer for colonoscopy(NNR). Advanced neoplasia was detected in 364 (6.2%) subjects. The German system referred the least proportion of subjects (11.2%) for colonoscopy, whilst the KCS scoring system referred the highest (27.4%). The c-statistics of all systems ranged from 0.56-0.65, with sensitivities ranging from 0.04-0.44 and specificities from 0.74-0.99. The modified APCS scoring system had the highest c-statistics (0.65, 95% C.I. 0.58-0.72). The NNS (12-19) and NNR (5-10) were similar among the scoring systems. The existing scoring systems have variable capability to predict advanced neoplasia among asymptomatic Chinese subjects, and further external validation should be performed.

  3. Propofol and non-propofol based sedation for outpatient colonoscopy-prospective comparison of depth of sedation using an EEG based SEDLine monitor.

    PubMed

    Goudra, Basavana; Singh, Preet Mohinder; Gouda, Gowri; Borle, Anuradha; Carlin, Augustus; Yadwad, Avantika

    2016-10-01

    Propofol is a popular anesthetic sedative employed in colonoscopy. It is known to increase the patient satisfaction and improve throughput. However, there are concerns among the clinicians with regard to the depth of sedation, as a deeper degree of sedation is known to increase the incidence of aspiration and other adverse events. So we planned to compare the depth of sedation between propofol and non-propofol based sedation in patients undergoing outpatient colonoscopy, as measured by an electroencephalogram (EEG) based monitor SEDLine monitor (SedlineInc., San Diego, CA). The non-randomized prospective observational study was performed in the outpatient gastroenterology suite of the Hospital of the University of Pennsylvania, Philadelphia. Patients included ASA class I-III aged more than 18 years scheduled for colonoscopy under Propofol or non-propofol based sedation. After an institutional review board approval, a written consent was obtained from prospective patients. Sedation (propofol or non-propofol based) was administered by either a certified nurse anesthetist under the supervision of an anesthesiologist (propofol) or a registered endoscopy nurse under the guidance of the endoscopist performing the procedure (non-propofol sedation). Depth of sedation was measured with an EEG based SEDLine monitor. The sedation providers were blinded to the patient state index-the indicator of depth of sedation. PSI (patient state index-SEDLine reading) was documented at colonoscope insertion, removal and at the return of verbal responsiveness after colonoscope withdrawal. Sedation spectrum was retrieved from the data stored on the SEDLine monitor. Patients sedated with propofol experience significantly deeper degrees of sedation at all times during the procedure. Additionally, during significant part of the procedure, they are at PSI levels associated with deep general anesthesia. The group that received propofol was more deeply sedated and had lower PSI values. Lighter propofol titration protocols may lead to improved patient care such as lowering risk of aspiration and hypotension. The role of processed EEG monitors such as the SEDLine monitor to improve sedation protocols remains to be determined. Trial registration We obtained an ethical clearance from the Institute. No trial registration was mandated, as no interventional drug or investigational device were used during the study.

  4. Public reporting of colonoscopy quality is associated with an increase in endoscopist adenoma detection rate.

    PubMed

    Abdul-Baki, Heitham; Schoen, Robert E; Dean, Katie; Rose, Sherri; Leffler, Daniel A; Kuganeswaran, Eliathamby; Morris, Michele; Carrell, David; Mehrotra, Ateev

    2015-10-01

    Colonoscopy is the predominant method for colorectal cancer screening in the United States. Previous studies have documented variation across physicians in colonoscopy quality as measured by the adenoma detection rate (ADR). ADR is the primary quality measure of colonoscopy examinations and an indicator of the likelihood of subsequent colorectal cancer. There is interest in mechanisms to improve the ADR. In Central Illinois, a local employer and a quality improvement organization partnered to publically report physician colonoscopy quality. We assessed whether this initiative was associated with an improvement in the ADR. We compared ADRs before and after public reporting at a private practice endoscopy center with 11 gastroenterologists in Peoria, Illinois, who participated in the initiative. To generate the ADR, colonoscopy and pathology reports from examinations performed over 4 years at the endoscopy center were analyzed by using previously validated natural language processing software. A central Illinois endoscopy center. The ADR in the pre-public reporting period was 34.3% and 39.2% in the post-public reporting period (an increase of 4.9%, P < .001). The increase in the right-sided ADR was 5.1% (P < .01), whereas the increase in the left-sided ADR was 2.1% (P < .05). The increase in the ADR was 7.8% for screening colonoscopies (P < 0.05) and 3.5% for nonscreening colonoscopies (P < .05). All but 1 physician's ADR increased (range -2.7% to 10.5%). There was no statistically significant change in the advanced ADR (increase of 0.8%, P = .22). There was no concurrent control group to assess whether the increased ADR was due to a secular trend. A public reporting initiative on colonoscopy quality was associated with an increase in ADR. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Nonneoplastic polypectomy during screening colonoscopy: the impact on polyp detection rate, adenoma detection rate, and overall cost.

    PubMed

    Atia, Mary A; Patel, Neal C; Ratuapli, Shiva K; Boroff, Erika S; Crowell, Michael D; Gurudu, Suryakanth R; Faigel, Douglas O; Leighton, Jonathan A; Ramirez, Francisco C

    2015-08-01

    The frequency of nonneoplastic polypectomy (NNP) and its impact on the polyp detection rate (PDR) is unknown. The correlation between NNP and adenoma detection rate (ADR) and its impact on the cost of colonoscopy has not been investigated. To determine the rate of NNP in screening colonoscopy, the impact of NNP on the PDR, and the correlation of NNP with ADR. The increased cost of NNP during screening colonoscopy also was calculated. We reviewed all screening colonoscopies. PDR and ADR were calculated. We then calculated a nonneoplastic polyp detection rate (patients with ≥1 nonneoplastic polyp). Tertiary-care referral center. Patients who underwent screening colonoscopies from 2010 to 2011. Colonoscopy. ADR, PDR, NNP rate. A total of 1797 colonoscopies were reviewed. Mean (±standard deviation) PDR was 47.7%±12.0%, and mean ADR was 27.3%±6.9%. The overall NNP rate was 10.4%±7.1%, with a range of 2.4% to 28.4%. Among all polypectomies (n=2061), 276 were for nonneoplastic polyps (13.4%). Endoscopists with a higher rate of nonneoplastic polyp detection were more likely to detect an adenoma (odds ratio 1.58; 95% confidence interval, 1.1-1.2). With one outlier excluded, there was a strong correlation between ADR and NNP (r=0.825; P<.001). The increased cost of removal of nonneoplastic polyps was $32,963. Retrospective study. There is a strong correlation between adenoma detection and nonneoplastic polyp detection. The etiology is unclear, but nonneoplastic polyp detection rate may inflate the PDR for some endoscopists. NNP also adds an increased cost. Increasing the awareness of endoscopic appearances through advanced imaging techniques of normal versus neoplastic tissue may be an area to improve cost containment in screening colonoscopy. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  6. Optimizing time management after perforation by colonoscopy results in better outcome for the patients.

    PubMed

    Rumstadt, Bernhard; Schilling, Dieter

    2008-01-01

    Perforation during colonoscopy is a rare but severe complication. The aim of this study was to assess the time management and laparoscopic therapy of this complication and to evaluate patient outcomes. A retrospective analysis was done on 15 patients operated for a perforation from colonoscopy between January 2000 and December 2006. Three perforations occurred during diagnostic and 12 perforations during interventional colonoscopy. Two perforations occurred as transmural thermal injury to the colon wall. Peritonitis was found in 4 cases and significantly correlated with the mean time between perforation and operation. Twelve perforations were oversewn laparoscopically and 3 perforations were oversewn by laparotomy. After laparoscopic treatment, hospital stay was significantly shorter than after laparotomy. One patient had a postoperative wound infection, mortality was 0%. Laparoscopic oversewing is a safe and effective method in the treatment of perforation from colonoscopy. Optimizing the time range between perforation and laparoscopic therapy results in a better outcome for the patients.

  7. Multilevel predictors of colorectal cancer testing modality among publicly and privately insured people turning 50.

    PubMed

    Wheeler, Stephanie B; Kuo, Tzy-Mey; Meyer, Anne Marie; Martens, Christa E; Hassmiller Lich, Kristen M; Tangka, Florence K L; Richardson, Lisa C; Hall, Ingrid J; Smith, Judith Lee; Mayorga, Maria E; Brown, Paul; Crutchfield, Trisha M; Pignone, Michael P

    2017-06-01

    Understanding multilevel predictors of colorectal cancer (CRC) screening test modality can help inform screening program design and implementation. We used North Carolina Medicare, Medicaid, and private, commercially available, health plan insurance claims data from 2003 to 2008 to ascertain CRC test modality among people who received CRC screening around their 50th birthday, when guidelines recommend that screening should commence for normal risk individuals. We ascertained receipt of colonoscopy, fecal occult blood test (FOBT) and fecal immunochemical test (FIT) from billing codes. Person-level and county-level contextual variables were included in multilevel random intercepts models to understand predictors of CRC test modality, stratified by insurance type. Of 12,570 publicly-insured persons turning 50 during the study period who received CRC testing, 57% received colonoscopy, whereas 43% received FOBT/FIT, with significant regional variation. In multivariable models, females with public insurance had lower odds of colonoscopy than males (odds ratio [OR] = 0.68; p < 0.05). Of 56,151 privately-insured persons turning 50 years old who received CRC testing, 42% received colonoscopy, whereas 58% received FOBT/FIT, with significant regional variation. In multivariable models, females with private insurance had lower odds of colonoscopy than males (OR = 0.43; p < 0.05). People living 10-15 miles away from endoscopy facilities also had lower odds of colonoscopy than those living within 5 miles (OR = 0.91; p < 0.05). Both colonoscopy and FOBT/FIT are widely used in North Carolina among insured persons newly age-eligible for screening. The high level of FOBT/FIT use among privately insured persons and women suggests that renewed emphasis on FOBT/FIT as a viable screening alternative to colonoscopy may be important.

  8. Screening Women Aged 50-59 for CRC Using Fecal Occult Blood Test Produces Outcomes Similar to Men Undergoing Screening Colonoscopy.

    PubMed

    Mooers, Harrison M; Holub, Jennifer L; Lieberman, David A

    2018-06-13

    Average-risk women aged 50-59 years have a lower incidence and mortality of colorectal cancer relative to age-matched men, calling into question the benefit of screening colonoscopy in this age group. We aimed to determine whether FOBT is an effective initial screening test in 50-59-year-old women. We conducted a cross-sectional study using a computerized endoscopic report generator. We identified 320,906 individuals who had average-risk screening colonoscopy and 32,369 who had colonoscopy for positive FOBT. The primary outcome was the positive predictive value (PPV) of FOBT for large polyp(s) greater than 9 mm, as a surrogate for advanced neoplasia. Among patients aged 50-59 years undergoing screening colonoscopy, men were more likely than women to have large polyps (6.3 vs 4.2%, p < 0.0001). Black women undergoing screening colonoscopy had higher rates of large polyps compared to non-Black women. The PPV in FOBT-positive men aged 50-54 (11.5%) and 55-59 (14.4%) was higher than in women aged 50-54 (6.1%) and 55-59 (5.4%). Despite this lower PPV, women aged 50-54 with a positive FOBT had a similar rate of large polyps as 50-54-year-old men undergoing screening colonoscopy (6.1 vs 6.3%, p = 0.626). CRC screening with FOBT identifies 50-59-year-old men and women with a higher risk of large polyps. Since younger women have a lower risk of large polyps than men, screening with FOBT in 50-59-year-old non-Black women could be an effective screening strategy, with outcomes similar to the use of screening colonoscopy in 50-59-year-old men.

  9. Quality control of colonoscopy procedures: a prospective validated method for the evaluation of professional practices applicable to all endoscopic units.

    PubMed

    Coriat, R; Pommaret, E; Chryssostalis, A; Viennot, S; Gaudric, M; Brezault, C; Lamarque, D; Roche, H; Verdier, D; Parlier, D; Prat, F; Chaussade, S

    2009-02-01

    To produce valid information, an evaluation of professional practices has to assess the quality of all practices before, during and after the procedure under study. Several auditing techniques have been proposed for colonoscopy. The purpose of this work is to describe a straightforward original validated method for the prospective evaluation of professional practices in the field of colonoscopy applicable in all endoscopy units without increasing the staff work load. Pertinent quality-control criteria (14 items) were identified by the endoscopists at the Cochin Hospital and were compatible with: findings in the available literature; guidelines proposed by the Superior Health Authority; and application in any endoscopy unit. Prospective routine data were collected and the methodology validated by evaluating 50 colonoscopies every quarter for one year. The relevance of the criteria was assessed using data collected during four separate periods. The standard checklist was complete for 57% of the colonoscopy procedures. The colonoscopy procedure was appropriate according to national guidelines in 94% of cases. These observations were particularly noteworthy: the quality of the colonic preparation was insufficient for 9% of the procedures; complete colonoscopy was achieved for 93% of patients; and 0.38 adenomas and 0.045 carcinomas were identified per colonoscopy. This simple and reproducible method can be used for valid quality-control audits in all endoscopy units. In France, unit-wide application of this method enables endoscopists to validate 100 of the 250 points required for continuous medical training. This is a quality-control tool that can be applied annually, using a random month to evaluate any changes in routine practices.

  10. Endotics system vs colonoscopy for the detection of polyps

    PubMed Central

    Tumino, Emanuele; Sacco, Rodolfo; Bertini, Marco; Bertoni, Michele; Parisi, Giuseppe; Capria, Alfonso

    2010-01-01

    AIM: To compare the endotics system (ES), a set of new medical equipment for diagnostic colonoscopy, with video-colonoscopy in the detection of polyps. METHODS: Patients with clinical or familial risk of colonic polyps/carcinomas were eligible for this study. After a standard colonic cleaning, detection of polyps by the ES and by video-colonoscopy was performed in each patient on the same day. In each single patient, the assessment of the presence of polyps was performed by two independent endoscopists, who were randomly assigned to evaluate, in a blind fashion, the presence of polyps either by ES or by standard colonoscopy. The frequency of successful procedures (i.e. reaching to the cecum), the time for endoscopy, and the need for sedation were recorded. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the ES were also calculated. RESULTS: A total of 71 patients (40 men, mean age 51.9 ± 12.0 years) were enrolled. The cecum was reached in 81.6% of ES examinations and in 94.3% of colonoscopies (P = 0.03). The average time of endoscopy was 45.1 ± 18.5 and 23.7 ± 7.2 min for the ES and traditional colonoscopy, respectively (P < 0.0001). No patient required sedation during ES examination, compared with 19.7% of patients undergoing colonoscopy (P < 0.0001). The sensitivity and specificity of ES for detecting polyps were 93.3% (95% CI: 68-98) and 100% (95% CI: 76.8-100), respectively. PPV was 100% (95% CI: 76.8-100) and NPV was 97.7% (95% CI: 88-99.9). CONCLUSION: The ES allows the visualization of the entire colonic mucosa in most patients, with good sensitivity/specificity for the detection of lesions and without requiring sedation. PMID:21086563

  11. The effectiveness of simethicone in improving visibility during colonoscopy.

    PubMed

    Park, Jae Jun; Lee, Sang Kil; Jang, Jae Young; Kim, Hyo Jong; Kim, Nam Hoon

    2009-01-01

    In colonoscopy examination, luminal visibility is frequently limited due to intraluminal bubbles. In present study was evaluated factors affecting bubble formation and the effects of simethicone in preventing bubble formation during colonoscopy. Consecutive patients (n=164) who received polyethylene glycol or sodium phosphate for bowel preparation were prospectively enrolled. Before colonoscopy, 57 patients took 80 mg simethicone after ingestion of bowel preparation solution and 107 did not to determine whether simethicone decreased bubble formation. Intraluminal gas bubbles were assessed and graded as follows: 0, minimal or none; 1, covering less than half the lumen; 2, covering at least half the lumen or the entire circumference. Grade 2 bubbles were regarded as significant, limiting visibility. Sodium phosphate preparation tended to have more bubbles than the polyethylene glycol. Significant bubbles were more likely to occur in males than females (p = 0.020). Significant bubbles were noted in 34.6% of patients without simethicone and 7% of patients with simethicone. Simethicone significantly lowered the incidence of bubbles during colonoscopy when given after a preparation solution (p < 0.05), The present study findings indicate that taking simethicone after an oral polyethylene glycol or sodium phosphate preparation can improve colonic visibility by diminishing colonic bubbles.

  12. Retention of colonoscopy skills after virtual reality simulator training by independent and proctored methods.

    PubMed

    Snyder, Christopher W; Vandromme, Marianne J; Tyra, Sharon L; Hawn, Mary T

    2010-07-01

    Virtual reality (VR) simulators may enhance surgical resident colonoscopy skills, but the duration of skill retention and the effects of different simulator training methods are unknown. Medical students participating in a randomized trial of independent (automated simulator feedback only) versus proctored (human expert feedback plus simulator feedback) simulator training performed a standardized VR colonoscopy scenario at baseline, at the end of training (posttraining), and after a median 4.5 months without practice (retention). Performances were scored on a 10-point scale based on expert proficiency criteria and compared for the independent and proctored groups. Thirteen trainees (8 proctored, 5 independent) were included. Performance at retention testing was significantly better than baseline (median score 10 vs. 5, P < 0.0001), and no different from posttraining (median score 10 vs. 10, P = 0.19). Score changes from baseline to retention and from posttraining to retention were no different for the proctored and independent groups. Overinsufflation and excessive force were the most common reasons for nonproficiency at retention. After proficiency-based VR simulator training, colonoscopy skills are retained for several months, regardless of whether an independent or proctored approach is used. Error avoidance skills may not be retained as well as speed and efficiency skills.

  13. Cost-Effectiveness Analysis of Six Strategies to Treat Recurrent Clostridium difficile Infection

    PubMed Central

    Lapointe-Shaw, Lauren; Tran, Kim L.; Coyte, Peter C.; Hancock-Howard, Rebecca L.; Powis, Jeff; Poutanen, Susan M.; Hota, Susy

    2016-01-01

    Objective To assess the cost-effectiveness of six treatment strategies for patients diagnosed with recurrent Clostridium difficile infection (CDI) in Canada: 1. oral metronidazole; 2. oral vancomycin; 3.oral fidaxomicin; 4. fecal transplantation by enema; 5. fecal transplantation by nasogastric tube; and 6. fecal transplantation by colonoscopy. Perspective Public insurer for all hospital and physician services. Setting Ontario, Canada. Methods A decision analytic model was used to model costs and lifetime health effects of each strategy for a typical patient experiencing up to three recurrences, over 18 weeks. Recurrence data and utilities were obtained from published sources. Cost data was obtained from published sources and hospitals in Toronto, Canada. The willingness-to-pay threshold was $50,000/QALY gained. Results Fecal transplantation by colonoscopy dominated all other strategies in the base case, as it was less costly and more effective than all alternatives. After accounting for uncertainty in all model parameters, there was an 87% probability that fecal transplantation by colonoscopy was the most beneficial strategy. If colonoscopy was not available, fecal transplantation by enema was cost-effective at $1,708 per QALY gained, compared to metronidazole. In addition, fecal transplantation by enema was the preferred strategy if the probability of recurrence following this strategy was below 8.7%. If fecal transplantation by any means was unavailable, fidaxomicin was cost-effective at an additional cost of $25,968 per QALY gained, compared to metronidazole. Conclusion Fecal transplantation by colonoscopy (or enema, if colonoscopy is unavailable) is cost-effective for treating recurrent CDI in Canada. Where fecal transplantation is not available, fidaxomicin is also cost-effective. PMID:26901316

  14. Cost-Effectiveness Analysis of Six Strategies to Treat Recurrent Clostridium difficile Infection.

    PubMed

    Lapointe-Shaw, Lauren; Tran, Kim L; Coyte, Peter C; Hancock-Howard, Rebecca L; Powis, Jeff; Poutanen, Susan M; Hota, Susy

    2016-01-01

    To assess the cost-effectiveness of six treatment strategies for patients diagnosed with recurrent Clostridium difficile infection (CDI) in Canada: 1. oral metronidazole; 2. oral vancomycin; 3.oral fidaxomicin; 4. fecal transplantation by enema; 5. fecal transplantation by nasogastric tube; and 6. fecal transplantation by colonoscopy. Public insurer for all hospital and physician services. Ontario, Canada. A decision analytic model was used to model costs and lifetime health effects of each strategy for a typical patient experiencing up to three recurrences, over 18 weeks. Recurrence data and utilities were obtained from published sources. Cost data was obtained from published sources and hospitals in Toronto, Canada. The willingness-to-pay threshold was $50,000/QALY gained. Fecal transplantation by colonoscopy dominated all other strategies in the base case, as it was less costly and more effective than all alternatives. After accounting for uncertainty in all model parameters, there was an 87% probability that fecal transplantation by colonoscopy was the most beneficial strategy. If colonoscopy was not available, fecal transplantation by enema was cost-effective at $1,708 per QALY gained, compared to metronidazole. In addition, fecal transplantation by enema was the preferred strategy if the probability of recurrence following this strategy was below 8.7%. If fecal transplantation by any means was unavailable, fidaxomicin was cost-effective at an additional cost of $25,968 per QALY gained, compared to metronidazole. Fecal transplantation by colonoscopy (or enema, if colonoscopy is unavailable) is cost-effective for treating recurrent CDI in Canada. Where fecal transplantation is not available, fidaxomicin is also cost-effective.

  15. Asia Pacific consensus recommendations for colorectal cancer screening.

    PubMed

    Sung, J J Y; Lau, J Y W; Young, G P; Sano, Y; Chiu, H M; Byeon, J S; Yeoh, K G; Goh, K L; Sollano, J; Rerknimitr, R; Matsuda, T; Wu, K C; Ng, S; Leung, S Y; Makharia, G; Chong, V H; Ho, K Y; Brooks, D; Lieberman, D A; Chan, F K L

    2008-08-01

    Colorectal cancer (CRC) is rapidly increasing in Asia, but screening guidelines are lacking. Through reviewing the literature and regional data, and using the modified Delphi process, the Asia Pacific Working Group on Colorectal Cancer and international experts launch consensus recommendations aiming to improve the awareness of healthcare providers of the changing epidemiology and screening tests available. The incidence, anatomical distribution and mortality of CRC among Asian populations are not different compared with Western countries. There is a trend of proximal migration of colonic polyps. Flat or depressed lesions are not uncommon. Screening for CRC should be started at the age of 50 years. Male gender, smoking, obesity and family history are risk factors for colorectal neoplasia. Faecal occult blood test (FOBT, guaiac-based and immunochemical tests), flexible sigmoidoscopy and colonoscopy are recommended for CRC screening. Double-contrast barium enema and CT colonography are not preferred. In resource-limited countries, FOBT is the first choice for CRC screening. Polyps 5-9 mm in diameter should be removed endoscopically and, following a negative colonoscopy, a repeat examination should be performed in 10 years. Screening for CRC should be a national health priority in most Asian countries. Studies on barriers to CRC screening, education for the public and engagement of primary care physicians should be undertaken. There is no consensus on whether nurses should be trained to perform endoscopic procedures for screening of colorectal neoplasia.

  16. Colonoscopic screening shows increased early incidence and progression of adenomas in cystic fibrosis

    PubMed Central

    Niccum, David E.; Billings, Joanne L.; Dunitz, Jordan M.; Khoruts, Alexander

    2018-01-01

    Background Colorectal cancer is an emerging problem in cystic fibrosis (CF). The goal of this study was to evaluate adenoma detection by systematic colonoscopic screening and surveillance. Methods We analyzed prospectively collected results of colonoscopies initiated at age 40 years from 88 CF patients at a single Cystic Fibrosis Center. We also reviewed results of diagnostic colonoscopies from 27 patients aged 30–39 years performed during the same time period at the Center. Results The incidence of polyp detection increased markedly after age 40 in CF patients. Greater than 50% were found to have adenomatous polyps; approximately 25% had advanced adenomas as defined by size and/or histopathology; 3% were found to have colon cancer. Multivariate analysis demonstrated specific risk factors for adenoma formation and progression. Conclusions Early screening and more frequent surveillance should be considered in patients with CF due to early incidence and progression of adenomas in this patient population. PMID:26851188

  17. Does geography influence the treatment and outcomes of colorectal cancer? A population-based analysis.

    PubMed

    Helewa, Ramzi M; Turner, Donna; Wirtzfeld, Debrah; Park, Jason; Hochman, David; Czaykowski, Piotr; Singh, Harminder; Shu, Emma; Xue, Lin; McKay, Andrew

    2013-06-17

    The Canadian province of Manitoba covers a large geographical area but only has one major urban center, Winnipeg. We sought to determine if regional differences existed in the quality of colorectal cancer care in a publicly funded health care system. This was a population-based historical cohort analysis of the treatment and outcomes of Manitobans diagnosed with colorectal cancer between 2004 and 2006. Administrative databases were utilized to assess quality of care using published quality indicators. A total of 2,086 patients were diagnosed with stage I to IV colorectal cancer and 42.2% lived outside of Winnipeg. Patients from North Manitoba had a lower odds of undergoing major surgery after controlling for other confounders (odds ratio (OR): 0.48, 95% confidence interval (CI): 0.26 to 0.90). No geographic differences existed in the quality measures of 30-day operative mortality, consultations with oncologists, surveillance colonoscopy, and 5-year survival. However, there was a trend towards lower survival in North Manitoba. We found minimal differences by geography. However, overall compliance with quality measures is low and there are concerning trends in North Manitoba. This study is one of the few to evaluate population-based benchmarks for colorectal cancer therapy in Canada.

  18. Cost-effectiveness analysis of colorectal cancer screening methods in Iran.

    PubMed

    Allameh, Zahra; Davari, Majid; Emami, Mohammad Hasan

    2011-03-01

    Screening can prevent colorectal cancer from becoming advanced by early detection of precancerous lesions. Cost-effectiveness analysis of colorectal cancer screening methods is highly necessary due to increased prevalence, decreased age at onset and the limited budget in Iran. Methods of screening currently available in Iran were selected. A systematic search revealed the sensitivity and specificity of each method. For this study, a model for a 20 year screening period of a population of 100,000 apparently healthy persons of ages 45-65 years in Isfahan Province was used. The cost-effectiveness of each method and the ratio of cost-effectiveness were calculated based on this model. The most and the least effective methods were CT colonography and fecal occult blood test, respectively. The highest and lowest expenditures in the governmental sector were related to fecal occult blood test and flexible sigmoidoscopy and in the private sector, to CT colonography and fecal occult blood test, respectively. The cost per cancer detected in 20 years of screening in the governmental sector was 0.28, 0.22 and 0.42 billion Rials, respectively for screening by colonoscopy, flexible sigmoidoscopy and fecal occult blood test. In the private sector, these were 1.54 (colonoscopy), 1.68 (flexible sigmoidoscopy), and 1.60 (fecal occult blood test) billion and 2.58 billion Rials for CT colonography, respectively. Although CT colonography is the most effective method, it needs a budget of 2.58 billion Rials for each screened patient. If costs in the governmental sector are considered, flexible sigmoidoscopy would be the most cost-effective method for screening the 45 - 65-year-old population in Iran.

  19. The Impact of Patient Education with a Smartphone Application on the Quality of Bowel Preparation for Screening Colonoscopy

    PubMed Central

    Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub

    2017-01-01

    Background/Aims Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. Methods In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. Results The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p=0.007 by t-test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. Conclusions In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group. PMID:28669148

  20. Haptic interface of the KAIST-Ewha colonoscopy simulator II.

    PubMed

    Woo, Hyun Soo; Kim, Woo Seok; Ahn, Woojin; Lee, Doo Yong; Yi, Sun Young

    2008-11-01

    This paper presents an improved haptic interface for the Korea Advanced Institute of Science and Technology Ewha Colonoscopy Simulator II. The haptic interface enables the distal portion of the colonoscope to be freely bent while guaranteeing sufficient workspace and reflective forces for colonoscopy simulation. Its force-torque sensor measures the profiles of the user. Manipulation of the colonoscope tip is monitored by four deflection sensors and triggers computations to render accurate graphic images corresponding to the rotation of the angle knob. Tack sensors are attached to the valve-actuation buttons of the colonoscope to simulate air injection or suction as well as the corresponding deformation of the colon. A survey study for face validation was conducted, and the result shows that the developed haptic interface provides realistic haptic feedback for colonoscopy simulations.

  1. Budget-impact model for colonoscopy cost calculation and comparison between 2 litre PEG+ASC and sodium picosulphate with magnesium citrate or sodium phosphate oral bowel cleansing agents.

    PubMed

    Gruss, H-J; Cockett, A; Leicester, R J

    2012-01-01

    With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding perspective, the acquisition costs of bowel preparations should not be used as the primary reason to select the preferred treatment agent, but should be part of the consideration, with an emphasis on the clinical outcome.

  2. Colonoscopy tutorial software made with a cadaver's sectioned images.

    PubMed

    Chung, Beom Sun; Chung, Min Suk; Park, Hyung Seon; Shin, Byeong-Seok; Kwon, Koojoo

    2016-11-01

    Novice doctors may watch tutorial videos in training for actual or computed tomographic (CT) colonoscopy. The conventional learning videos can be complemented by virtual colonoscopy software made with a cadaver's sectioned images (SIs). The objective of this study was to assist colonoscopy trainees with the new interactive software. Submucosal segmentation on the SIs was carried out through the whole length of the large intestine. With the SIs and segmented images, a three dimensional model was reconstructed. Six-hundred seventy-one proximal colonoscopic views (conventional views) and corresponding distal colonoscopic views (simulating the retroflexion of a colonoscope) were produced. Not only navigation views showing the current location of the colonoscope tip and its course, but also, supplementary description views were elaborated. The four corresponding views were put into convenient browsing software to be downloaded free from the homepage (anatomy.co.kr). The SI colonoscopy software with the realistic images and supportive tools was available to anybody. Users could readily notice the position and direction of the virtual colonoscope tip and recognize meaningful structures in colonoscopic views. The software is expected to be an auxiliary learning tool to improve technique and related knowledge in actual and CT colonoscopies. Hopefully, the software will be updated using raw images from the Visible Korean project. Copyright © 2016 Elsevier GmbH. All rights reserved.

  3. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families.

    PubMed

    Burton-Chase, A M; Hovick, S R; Peterson, S K; Marani, S K; Vernon, S W; Amos, C I; Frazier, M L; Lynch, P M; Gritz, E R

    2013-03-01

    The purpose of this study was to examine colonoscopy adherence and attitudes toward colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation negative and 26 mutation positive). While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. To conclude, adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. © 2013 John Wiley & Sons A/S.

  4. Making every colonoscopy count: Ensuring quality in endoscopy.

    PubMed

    Bourke, Michael J

    2009-10-01

    The last few years have seen a burgeoning interest in the measurement of clinical performance and its impact on quality standards. The advent of the National Bowel Cancer Screening Program has highlighted the many deficiencies that exist in the provision of colonoscopy services in Australia. These include the absence of an agreed tool to measure the quality of colonoscopy on either an individual, departmental or regional basis and the absence of an endoscopic or colonoscopy training curriculum or an agreed standard for colonoscopy trainers. This review will discuss the current status and shortfalls of measuring quality in colonoscopy, highlight some recent initiatives by the Gastroenterological Society of Australia and articulate a direction for the future.

  5. Perforated Appendicitis After Colonoscopy

    PubMed Central

    Johnston, Paul

    2008-01-01

    Background: Acute appendicitis is a rare complication of colonoscopy that has been reported only 12 times in the English-language literature and is usually associated with obstruction of the appendiceal lumen with fecal matter during colonoscopy. None of the previous reports have described findings of perforation of the appendix within 24 hours of colonoscopy. Methods: We present the case report of a patient who underwent urgent laparotomy within 16 hours of colonos-copy for findings of free intraabdominal air and peritonitis from acute perforated appendicitis. Results: Laparoscopy confirmed 2 perforations of the appendix and diffuse peritonitis. Laparotomy was necessary to perform appendectomy, exclude a right colonic injury, and control intraabdominal sepsis. Conclusion: In patients with abdominal pain who have had a recent colonoscopy, a high index of suspicion is necessary for accurate diagnosis of perforated appendicitis. Perforation can occur hours after colonoscopy even when a biopsy is not performed. PMID:18765066

  6. [Appropriateness of colonoscopy indications according to the new EPAGE II criteria].

    PubMed

    Carrión, Silvia; Marín, Ingrid; Lorenzo-Zúñiga, Vicente; Moreno De Vega, Vicente; Boix, Jaume

    2010-01-01

    The appropriateness criteria for colonoscopy developed by a European expert panel (EPAGE), published in 1999, were revised this year (EPAGE II), but have not yet been evaluated. (1) To analyze colonoscopies performed at our hospital, and (2) to evaluate the appropriateness of the new EPAGE II criteria. We retrospectively analyzed 700 colonoscopies (48% males, mean age 58 years). Forty-five colonoscopies (6.4%) were excluded for insufficient bowel preparation or elective indication. EPAGE II criteria classified colonoscopies as "appropriate", "inappropriate" and "uncertain". Ninety-four percent (n=655) of colonoscopies were evaluated. The most frequent indication for colonoscopy (19%) was screening of colorectal cancer (CRC). Seventy percent of colonoscopies were "appropriate", and 18% were "inappropriate", with significant differences according to where the request was made. The most inappropriate indication was postpolypectomy follow-up, due to shorter follow-up intervals. An endoscopic diagnosis was made in 315 patients (48%), with a finding of significant lesions in 25% (n=167; CCR, adenomas, inflammatory bowel disease, angiodysplasia and benign stricture). The indications most frequently associated with relevant findings were screening of CRC (17.3%) and postpolypectomy follow-up (16.7%) but this association was non-significant. Only iron-deficiency anemia was significantly associated with CRC (p<0.0001). Eighteen percent of requests for colonoscopy were inappropriate and 12% provided incomplete information. The indication most strongly associated with a diagnosis of CRC was iron-deficiency anemia. The EPAGE II criteria showed a significant correlation with an endoscopic diagnosis of CRC.

  7. A nurse-led model at public academic hospitals maintains high adherence to colorectal cancer surveillance guidelines.

    PubMed

    Symonds, Erin L; Simpson, Kalindra; Coats, Michelle; Chaplin, Angela; Saxty, Karen; Sandford, Jayne; Young Am, Graeme P; Cock, Charles; Fraser, Robert; Bampton, Peter A

    2018-06-18

    To examine the compliance of colorectal cancer surveillance decisions for individuals at greater risk with current evidence-based guidelines and to determine whether compliance differs between surveillance models. Prospective auditing of compliance of surveillance decisions with evidence-based guidelines (NHMRC) in two decision-making models: nurse coordinator-led decision making in public academic hospitals and physician-led decision making in private non-academic hospitals. Selected South Australian hospitals participating in the Southern Co-operative Program for the Prevention of Colorectal Cancer (SCOOP). Proportions of recall recommendations that matched NHMRC guideline recommendations (March-May 2015); numbers of surveillance colonoscopies undertaken more than 6 months ahead of schedule (January-December 2015); proportions of significant neoplasia findings during the 15 years of SCOOP operation (2000-2015). For the nurse-led/public academic hospital model, the recall interval recommendation following 398 of 410 colonoscopies (97%) with findings covered by NHMRC guidelines corresponded to the guideline recommendations; for the physician-led/private non-academic hospital model, this applied to 257 of 310 colonoscopies (83%) (P < 0.001). During 2015, 27% of colonoscopies in public academic hospitals (mean, 27 months; SD, 13 months) and 20% of those in private non-academic hospitals (mean, 23 months; SD, 12 months) were performed more than 6 months earlier than scheduled, in most cases because of patient-related factors (symptoms, faecal occult blood test results). The ratio of the numbers of high risk adenomas to cancers increased from 6.6:1 during 2001-2005 to 16:1 during 2011-2015. The nurse-led/public academic hospital model for decisions about colorectal cancer surveillance intervals achieves a high degree of compliance with guideline recommendations, which should relieve burdening of colonoscopy resources.

  8. Effectiveness of a multimedia-based educational intervention for improving colon cancer literacy in screening colonoscopy patients.

    PubMed

    Hassinger, James P; Holubar, Stefan D; Pendlimari, Rajesh; Dozois, Eric J; Larson, David W; Cima, Robert R

    2010-09-01

    Limited data exist regarding colon cancer literacy in screening colonoscopy patients. We aimed to prospectively assess baseline colon cancer literacy and to determine whether a multimedia educational intervention was associated with improved colon cancer literacy. Colon cancer literacy was assessed in a convenience sample of colonoscopy patients before and after educational intervention. Statistically significant associations with colon cancer literacy scores were assessed by use of multivariate logistic regression analysis. Results are frequency (proportion), mean +/- SD, and odds ratio (OR (95% CI)). Seventy-three subjects participated: mean age, 57 +/- 12 years, 35 (48%) were women, 41 (57%) had a college degree, 43 (59%) had prior colonoscopy, 21 (29%) were accompanying family, and 16 (22%) were health care employees. Multivariate factors associated with a higher baseline colon cancer literacy score included health care employee status (7.9 (95% CI, 1.6-63); P = .02) and family colon cancer history (5.3 (95% CI, 1.3-25); P = .02). After multimedia education, mean scores improved from 53% +/- 23% to 88% +/- 12% (Delta = 35%; P < .0001). On univariate analysis, college-educated subjects had higher final scores (91% vs 83%; P = .007), but this association was not significant on multivariate regression (P = .07). Only baseline score was associated with higher postintervention score (1.7 (95% CI, 1.2-2.6); P = .005). Sixty-two subjects (86%) were very satisfied, and 70 (97%) would recommend the module to friends and family. A knowledge deficit of colon cancer-related concepts is frequently observed in patients undergoing screening colonoscopy. Multimedia-based educational intervention was an effective, satisfying strategy for addressing cancer-specific knowledge deficit in laypersons.

  9. Accurate motion parameter estimation for colonoscopy tracking using a regression method

    NASA Astrophysics Data System (ADS)

    Liu, Jianfei; Subramanian, Kalpathi R.; Yoo, Terry S.

    2010-03-01

    Co-located optical and virtual colonoscopy images have the potential to provide important clinical information during routine colonoscopy procedures. In our earlier work, we presented an optical flow based algorithm to compute egomotion from live colonoscopy video, permitting navigation and visualization of the corresponding patient anatomy. In the original algorithm, motion parameters were estimated using the traditional Least Sum of squares(LS) procedure which can be unstable in the context of optical flow vectors with large errors. In the improved algorithm, we use the Least Median of Squares (LMS) method, a robust regression method for motion parameter estimation. Using the LMS method, we iteratively analyze and converge toward the main distribution of the flow vectors, while disregarding outliers. We show through three experiments the improvement in tracking results obtained using the LMS method, in comparison to the LS estimator. The first experiment demonstrates better spatial accuracy in positioning the virtual camera in the sigmoid colon. The second and third experiments demonstrate the robustness of this estimator, resulting in longer tracked sequences: from 300 to 1310 in the ascending colon, and 410 to 1316 in the transverse colon.

  10. Green tea extracts for the prevention of metachronous colorectal adenomas: a pilot study.

    PubMed

    Shimizu, Masahito; Fukutomi, Yasushi; Ninomiya, Mitsuo; Nagura, Kazuo; Kato, Tomohiro; Araki, Hiroshi; Suganuma, Masami; Fujiki, Hirota; Moriwaki, Hisataka

    2008-11-01

    Experimental studies indicate the chemopreventive properties of green tea extract (GTE) on colorectal cancer. Epidemiologically, green tea consumption of > 10 cups daily reduced colorectal cancer risk in Japanese. Because colorectal adenomas are the precursors to most sporadic colorectal cancers, we conducted a randomized trial to determine the preventive effect of GTE supplements on metachronous colorectal adenomas by raising green tea consumption in the target population from an average of 6 cups (1.5 g GTE) daily to > or = 10 cups equivalent (2.5 g GTE) by supplemental GTE tablets. We recruited 136 patients, removed their colorectal adenomas by endoscopic polypectomy, and 1 year later confirmed the clean colon (i.e., no polyp) at the second colonoscopy. The patients were then randomized into two groups while maintaining their lifestyle on green tea drinking: 71 patients supplemented with 1.5 g GTE per day for 12 months and 65 control patients without supplementation. Follow-up colonoscopy was conducted 12 months later in 125 patients (65 in the control group and 60 in the GTE group). The incidence of metachronous adenomas at the end-point colonoscopy was 31% (20 of 65) in the control group and 15% (9 of 60) in the GTE group (relative risk, 0.49; 95% confidence interval, 0.24-0.99; P < 0.05). The size of relapsed adenomas was also smaller in the GTE group than in the control group (P < 0.001). No serious adverse events occurred in the GTE group. GTE is an effective supplement for the chemoprevention of metachronous colorectal adenomas.

  11. Using resource modelling to inform decision making and service planning: the case of colorectal cancer screening in Ireland.

    PubMed

    Sharp, Linda; Tilson, Lesley; Whyte, Sophie; Ceilleachair, Alan O; Walsh, Cathal; Usher, Cara; Tappenden, Paul; Chilcott, James; Staines, Anthony; Barry, Michael; Comber, Harry

    2013-03-19

    Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55-74 years, and (c) biennial faecal immunochemical tests (FIT) at 55-74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55-64 years) and staggered age-based roll-out across the 55-74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55-74). FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381-1,053 with FSIG-based, and 967-1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning.

  12. Impact of a simulation training curriculum on technical and nontechnical skills in colonoscopy: a randomized trial.

    PubMed

    Grover, Samir C; Garg, Ankit; Scaffidi, Michael A; Yu, Jeffrey J; Plener, Ian S; Yong, Elaine; Cino, Maria; Grantcharov, Teodor P; Walsh, Catharine M

    2015-12-01

    GI endoscopy simulation-based training augments early clinical performance; however, the optimal manner by which to deliver training is unknown. We aimed to validate a simulation-based structured comprehensive curriculum (SCC) designed to teach technical, cognitive, and integrative competencies in colonoscopy. Single-blinded, randomized, controlled trial. Endoscopic simulation course at an academic hospital. Thirty-three novice endoscopists were allocated to an SCC group or self-regulated learning (SRL) group. The SCC group received a curriculum consisting of 6 hours of didactic lectures and 8 hours of virtual reality simulation-based training with expert feedback. The SRL group was provided a list of desired objectives and was instructed to practice on the simulator for an equivalent time (8 hours). Clinical transfer was assessed during 2 patient colonoscopies using the Joint Advisory Group Direct Observation of Procedural Skills (JAG DOPS) scale. Secondary outcome measures included differences in procedural knowledge, immediate post-training simulation performance, and delayed post-training (4-6 weeks) performance during an integrated scenario test on the JAG DOPS communication and integrated scenario global rating scales. There was no significant difference in baseline or post-training performance on the simulator task. The SCC group performed superiorly during their first and second clinical colonoscopies. Additionally, the SCC group demonstrated significantly better knowledge and colonoscopy-specific performance, communication, and global performance during the integrated scenario. We were unable to measure SRL participants' effort outside of mandatory training. In addition, feedback metrics and number of available simulation cases are limited. These results support integration of endoscopy simulation into a structured curriculum incorporating instructional feedback and complementary didactic knowledge as a means to augment technical, cognitive, and integrative skills acquisition, as compared with SRL on virtual reality simulators. ( NCT01991522.) Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  13. Estimation of the Adenoma Detection Rate From the Polyp Detection Rate by Using a Conversion Factor in a Predominantly Hispanic Population.

    PubMed

    Elhanafi, Sherif; Ortiz, Arleen M; Yarlagadda, Anita; Tsai, Cindy; Eloliby, Mohamed; Mallawaarachchi, Indika; Dwivedi, Alok; Zuckerman, Marc J; Othman, Mohamed O

    2015-08-01

    Calculating the adenoma detection rate (ADR) is a complex process in contrast to the polyp detection rate (PDR) that can be easily calculated. The average adenoma to polyp detection rate quotient (APDRQ) was proposed as a conversion factor to estimate the ADR for individual endoscopists from the endoscopist's PDR. However, this conversion factor was not validated in different practice settings. To validate the use of the proposed conversion factor in a practice setting with a predominantly Hispanic population. We conducted a retrospective, cross-sectional study (December 2007 to November 2012) of screening colonoscopies at a university practice setting with an 86.9% Hispanic population. The actual ADR and PDR were calculated for all endoscopists. The weighted average of ADR to PDR ratio for each endoscopist was used to obtain APDRQ. The APDRQ was used as a conversion multiplier to estimate each endoscopist's ADR using the single endoscopist's PDR. A total of 2148 screening colonoscopies were included. The average PDR for the whole group was 36.9% (range, 11% to 49%). The actual ADR was estimated as 25.5% (range, 11% to 37%). The average APDRQ for our group was 0.68. The estimated ADR was 25.48% (range, 8% to 33%). There was a high correlation between actual ADR and the estimated ADR (Pearson correlation=0.92). In a practice setting with a predominantly Hispanic population, a conversion factor can be used to estimate ADR from PDR providing a high degree of correlation with the actual ADR.

  14. Accuracy of 99mTc (V)-Dimercaptosuccinic Acid Scintigraphy and Fecal Calprotectin Compared with Colonoscopy in Localizing Active Lesions in Inflammatory Bowel Disease

    PubMed Central

    Basirat, Vahid; Azizi, Zahra; Javid Anbardan, Sanam; Taghizadeh Asl, Mina; Farbod, Yasaman; Teimouri, Azam; Ebrahimi Daryani, Nasser

    2016-01-01

    INTRODUCTION Due to limitation of colonoscopy in assessing the entire bowel and patients’ intolerance in inflammatory bowel disease (IBD), in the current study, we aimed to prospectively compare the accuracy of 99mTc(V)-dimercaptosuccinic acid (DMSA) and fecal calprotectin with ileocolonoscopy as new methods for localizing inflammations. METHODS Current prospective study conducted between 2012 and 2014 on 30 patients with IBD attending Gastroenterology Clinic of Tehran University of Medical Sciences. Fecal calprotectin and disease activity were measured for all participants and all of them underwent 99mTc (V)-DMSA scintigraphy and colonoscopy. The accuracy of 99mTc (V)-DMSA scintigraphy and calprotectin in localizing bowel lesions were calculated. RESULTS A total of 22 patients with ulcerative colitis (UC) and 8 patients with Crohn’s disease (CD) were evaluated in our study. Sensitivity, positive likelihood ratio (PLR), and positive predictive value (PPV) of scintigraphy and calprotectin over colonoscopy in localization of UC lesions were 86.36%, 0.86%, 100.00% and 90.91%, 0.91, and 100.00%, respectively. Meanwhile, it showed 66.67% sensitivity and 81.25% specificity with PLR=3.56, negative likelihood ratio (NLR)=0.41, PPV=84.21%, and negative predictive value (NPV)= 61.90% in localizing lesions in patients with CD. The calprotectin level had sensitivity, PLR, and PPV of 90.00%, 0.90, and 100.00% in detecting active disease over colonoscopy, respectively. CONCLUSION The 99mTc (V)-DMSA scintigraphy would be an accurate method for detecting active inflammation in follow-up of patients with IBD and assessing response to treatment as a non-invasive and complementary method beside colonoscopy for more accurate diagnosis of CD or UC. PMID:27698971

  15. Factors affecting colonoscope insertion time in patients with or without a colostomy after left-sided colorectal resection.

    PubMed

    Jang, Hui Won; Kim, Yoon Nam; Nam, Chung Mo; Lee, Hyun Jung; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2012-12-01

    We examined whether the insertion time for colonoscopies performed after left-sided resection was different in patients with a colostomy from that in patients without a colostomy and identified factors that could impact colonoscopy performance. We included consecutive patients who underwent colonoscopy between July 2005 and March 2011 after left-sided colorectal resection for colorectal cancer. We classified surgical methods according to the presence or absence of a colostomy and evaluated colonoscope insertion time retrospectively. Furthermore, we analyzed factors that might affect insertion time. A total of 1,041 patients underwent colonoscopy after left-sided colorectal resection during the study period. The colonoscopy completion rate was 98.6 %, and the mean insertion time was 6.1 ± 4.6 min (median 4.7 min, range 0.3-35.8 min). A shorter resection length of colon, the presence of a colostomy, and a lower endoscopist case volume were found to be independent factors associated with prolonged insertion time in patients with left-sided colorectal resection. Among experienced colonoscopists, no colonoscopy-associated or clinical factors were found to affect insertion time. However, a shorter resection length of colon, the presence of a colostomy, and poor bowel preparation were associated with prolonged insertion time among inexperienced endoscopists. We identified three factors that affect colonoscope insertion time after left-sided colorectal resection, including the presence of a colostomy. Inexperienced endoscopists were much more affected by the presence of a colostomy after left-sided colorectal resection. These findings have implications for the practice and teaching of colonoscopy after left-sided colorectal resection.

  16. Developing a tool to preserve eye contact with patients undergoing colonoscopy for pain monitoring

    PubMed Central

    Niv, Yaron; Tal, Yossi

    2012-01-01

    Colonoscopy has become the leading procedure for early detection and prevention of colorectal cancer. Patients’ experience of colonic endoscopic procedures is scarcely reported, even though it is considered a major factor in colorectal cancer screening participation. Pain due to air inflation or stretching the colon with an endoscope is not rare during examination and may be the main obstacle to cooperation and participation in a screening program. We propose a four-stage study for developing a tool dedicated to pain monitoring during colonoscopy, as follows: (1) comparison of patient, nurse, and endoscopist questionnaire responses about patient pain and technical details of the procedure using the PAINAD tool during colonoscopy; (2) observation of the correlation between patients’ facial expressions and other parameters (using the short PAINAD); (3) development of a device for continuous monitoring of the patient’s facial expression during the procedure; (4) assessment of the usability of such a tool and its contribution to the outcomes of colonoscopy procedures. Early intervention by the staff performing the procedure, in reaction to alerts encoded by this tool, may prevent adverse events during the procedure. PMID:22977314

  17. Endoscopic procedure with a modified Reiki intervention: a pilot study.

    PubMed

    Hulse, Rosalinda S; Stuart-Shor, Eileen M; Russo, Jonathan

    2010-01-01

    This pilot study examined the use of Reiki prior to colonoscopy to reduce anxiety and minimize intraprocedure medications compared with usual care. A prospective, nonblinded, partially randomized patient preference design was employed using 21 subjects undergoing colonoscopy for the first time. Symptoms of anxiety and pain were assessed using a Likert-type scale. Between-group differences were assessed using chi-square analyses and analysis of variance. There were no differences between the control (n = 10) and experimental (n = 11) groups on age (mean = 58 years, SD = 8.5) and gender (53% women). The experimental group had higher anxiety (4.5 vs. 2.6, p = .03) and pain (0.8 vs. 0.2, p = .42) scores prior to colonoscopy. The Reiki intervention reduced mean heart rate (-9 beats/minute), systolic blood pressure (-10 mmHg), diastolic blood pressure (-4 mmHg), and respirations (-3 breaths/minute). There were no between-group differences on intraprocedure medication use or postprocedure physiologic measures. Although the experimental group patients had more symptoms, they did not require additional pain medication during the procedure, suggesting that (1) anxious people may benefit from an adjunctive therapy; (2) anxiety and pain are decreased by Reiki therapy for patients undergoing colonoscopy, and (3) additional intraprocedure pain medication may not be needed for colonoscopy patients receiving Reiki therapy. This pilot study provided important insights in preparation for a rigorous, randomized, controlled clinical trial.

  18. Adenoma Detection Rate: I Will Show You Mine if You Show Me Yours

    PubMed Central

    Oliveira Ferreira, Alexandre; Fidalgo, Catarina; Palmela, Carolina; Costa Santos, Maria Pia; Torres, Joana; Nunes, Joana; Loureiro, Rui; Ferreira, Rosa; Barjas, Elídio; Glória, Luísa; Santos, António Alberto; Cravo, Marília

    2017-01-01

    Background Colorectal cancer (CRC) is the first cause of cancer-related mortality in Portugal. CRC screening reduces disease-specific mortality. Colonoscopy is currently the preferred method for screening as it may contribute to the reduction of CRC incidence. This beneficial effect is strongly associated with the adenoma detection rate (ADR). Aim Our aim was to evaluate the quality of colonoscopy at our unit by measuring the currently accepted quality parameters and publish them as benchmarking indicators. Methods From 5,860 colonoscopies, 654 screening procedures (with and without previous fecal occult blood testing) were analyzed. Results The mean age of the patients was 66.4 ± 7.8 years, and the gender distribution was 1:1. The overall ADR was 36% (95% confidence interval [CI] 32–39), the mean number of adenomas per colonoscopy was 0.66 (95% CI 0.56–0.77), and the sessile serrate lesion detection rate was 1% (95% CI 0–2). The bowel preparation was rated as adequate in 496 (76%) patients. The adjusted cecal intubation rate (CIR) was 93.7% (95% CI 91.7–95.8). Most colonoscopies were performed under monitored anesthesia care (53%), and 35% were unsedated. The use of sedation (propofol or midazolam based) was associated with a higher CIR with an odds ratio of 3.60 (95% CI 2.02–6.40, p < 0.001). Conclusion Our data show an above-standard ADR. The frequency of poor bowel preparation and the low sessile serrated lesion detection rate were acknowledged, and actions were implemented to improve both indicators. Quality auditing in colonoscopy should be compulsory, and while many units may do so internally, this is the first national report from a high-throughput endoscopy unit. PMID:28848785

  19. Impact of cap-assisted colonoscopy on the learning curve and quality in colonoscopy: a randomized controlled trial.

    PubMed

    Tang, Zhouwen; Zhang, Daniel S; Thrift, Aaron P; Patel, Kalpesh K

    2018-03-01

    Colonoscopy competency assessment in trainees traditionally has been informal. Comprehensive metrics such as the Assessment of Competency in Endoscopy (ACE) tool suggest that competency thresholds are higher than assumed. Cap-assisted colonoscopy (CAC) may improve competency, but data regarding novice trainees are lacking. We compared CAC versus standard colonoscopy (SC) performed by novice trainees in a randomized controlled trial. All colonoscopies performed by 3 gastroenterology fellows without prior experience were eligible for the study. Exclusion criteria included patient age <18 or >90 years, pregnancy, prior colon resection, diverticulitis, colon obstruction, severe hematochezia, referral for EMR, or a procedure done without patient sedation. Patients were randomized to either CAC or SC in a 1:1 fashion. The primary outcome was the independent cecal intubation rate (ICIR). Secondary outcomes were cecal intubation time, polyp detection rate, polyp miss rate, adenoma detection rate, ACE tool scores, and cumulative summation learning curves. A total of 203 colonoscopies were analyzed, 101 in CAC and 102 in SC. CAC resulted in a significantly higher cecal intubation rate, at 79.2% in CAC compared with 66.7% in SC (P = .04). Overall cecal intubation time was significantly shorter at 13.7 minutes for CAC versus 16.5 minutes for SC (P =.02). Cecal intubation time in the case of successful independent fellow intubation was not significantly different between CAC and SC (11.6 minutes vs 12.7 minutes; P = .29). Overall ACE tool motor and cognitive scores were higher with CAC. Learning curves for ICIR approached the competency threshold earlier with cap use but reached competency for only 1 fellow. The polyp detection rate, polyp miss rate, and adenoma detection rate were not significantly different between groups. CAC resulted in significant improvement in ICIR, overall ACE tool scores, and trend toward competency on learning curves when compared with SC in colonoscopy trainees without prior colonoscopy experience. (Clinical trial registration number: NCT02472730.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Pneumoperitoneum after virtual colonoscopy: causes, risk factors, and management.

    PubMed

    Baccaro, Leopoldo M; Markelov, Alexey; Wilhelm, Jakub; Bloch, Robert

    2014-06-01

    Computed tomographic virtual colonoscopy (CTVC) is a safe and minimally invasive modality when compared with fiberoptic colonoscopy for evaluating the colon and rectum. We have reviewed the risks for colonic perforation by investigating the relevant literature. The objectives of this study were to assess the risk of colonic perforation during CTVC, describe risk factors, evaluate ways to reduce the incidence complications, and to review management and treatment options. A formal search of indexed publications was performed through PubMed. Search queries using keywords "CT colonography," "CT virtual colonoscopy," "virtual colonoscopy," and "perforation" yielded a total of 133 articles. A total of eight case reports and four review articles were selected. Combining case reports and review articles, a total of 25 cases of colonic perforation after CTVC have been reported. Causes include, but are not limited to, diverticular disease, irritable bowel diseases, obstructive processes, malignancies, and iatrogenic injury. Both operative and nonoperative management has been described. Nonoperative management has been proven safe and successful in minimally symptomatic and stable patients. Colonic perforation after CTVC is a rare complication and very few cases have been reported. Several risk factors are recurrent in the literature and must be acknowledged at the time of the study. Management options vary and should be tailored to each individual patient.

  1. Early Adoption of a Multitarget Stool DNA Test for Colorectal Cancer Screening.

    PubMed

    Finney Rutten, Lila J; Jacobson, Robert M; Wilson, Patrick M; Jacobson, Debra J; Fan, Chun; Kisiel, John B; Sweetser, Seth; Tulledge-Scheitel, Sidna M; St Sauver, Jennifer L

    2017-05-01

    To characterize early adoption of a novel multitarget stool DNA (MT-sDNA) screening test for colorectal cancer (CRC) screening and to test the hypothesis that adoption differs by demographic characteristics and prior CRC screening behavior and proceeds predictably over time. We used the Rochester Epidemiology Project research infrastructure to assess the use of the MT-sDNA screening test in adults aged 50 to 75 years living in Olmsted County, Minnesota, in 2014 and identified 27,147 individuals eligible or due for screening colonoscopy from November 1, 2014, through November 30, 2015. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of the MT-sDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior CRC screening behavior. Overall, 2193 (8.1%) and 974 (3.6%) individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior CRC screening behavior were significantly and independently associated with MT-sDNA screening use compared with colonoscopy use after adjustment for all other variables (P<.05 for all). The rates of adoption of MT-sDNA screening increased over time and were highest in those aged 50 to 54 years, women, whites, and those who had a history of screening. The use of the MT-sDNA screening test varied predictably by insurance coverage. The rates of colonoscopy decreased over time, whereas overall CRC screening rates remained steady. The results of the present study are generally consistent with predictions derived from prior research and the diffusion of innovation framework, pointing to increasing use of the new screening test over time and early adoption by younger patients, women, whites, and those with prior CRC screening. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  2. Location of colorectal cancer: colonoscopy versus surgery. Yield of colonoscopy in predicting actual location.

    PubMed

    Blum-Guzman, Juan Pablo; Wanderley de Melo, Silvio

    2017-07-01

     Recent studies suggest that differences in biological characteristics and risk factors across cancer site within the colon and rectum may translate to differences in survival. It can be challenging at times to determine the precise anatomical location of a lesion with a luminal view during colonoscopy. The aim of this study is to determine if there is a significant difference between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative and pathology reports after colon surgery.  A single-center retrospective analysis of colonoscopies of patient with reported colonic masses from January 2005 to April 2014 (n = 380) was carried. Assessed data included demography, operative and pathology reports. Findings were compared: between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative reports or pathology samples.  We identified 380 colonic masses, 158 were confirmed adenocarcinomas. Of these 123 underwent surgical resection, 27 had to be excluded since no specific location was reported on their operative or pathology report. An absolute difference between endoscopic and surgical location was found in 32 cases (33 %). Of these, 22 (23 %) differed by 1 colonic segment, 8 (8 %) differed by 2 colonic segments and 2 (2 %) differed by 3 colonic segments.  There is a significant difference between the location of colorectal cancers reported by gastroenterologists during endoscopy and the actual anatomical location noted on operative or pathology reports after colon surgery. Endoscopic tattooing should be used when faced with any luminal lesions of interest.

  3. Pediatric colonoscopy in South China: a 12-year experience in a tertiary center.

    PubMed

    Lei, Pingguang; Gu, Fang; Hong, Liru; Sun, Yuli; Li, Minrui; Wang, Huiling; Zhong, Bihui; Chen, Minhu; Cui, Yi; Zhang, Shenghong

    2014-01-01

    To investigate: 1) the demographics and clinical characteristics, 2) the findings, and 3) the safety and effectiveness in a cohort of Chinese pediatric patients undergoing colonoscopy. The study participants were consecutive patients aged ≤14 years old that underwent their first colonoscopy in the endoscopy center at the First Affiliated Hospital, Sun Yat-sen University between Jan. 1, 2001 and Dec. 31, 2012. Demographic, clinical, endoscopic, and pathological findings were collected. The cohort consisted of 322 patients, including 218 boys (67.7%) and 104 girls (32.3%). The median age was 8.0 years old and ranged from 9 months to 14 years old. Hematochezia (48.8%) and abdominal pain/discomfort (41.3%) were the most common presentations preceding pediatric colonoscopy. The caecal intubation success rate was 96.3%. No serious complications occurred during the procedures. A total of 227 patients (70.5%) received a positive diagnosis under endoscopy, including 138 patients with polyps and 53 patients with inflammatory bowel disease (IBD). Among the patients with polyps, 71.0% were juvenile polyps. Comparisons between years 2001-2006 and 2007-2012 showed that the IBD detection rate increased significantly (4.6% vs. 22.4%, P<0.001), while the opposite occurred for the polyp detection rate (73.1% vs. 27.6%, P<0.001). Colonoscopy in pediatric patients is a safe and effective procedure. Polyps are the primary finding during colonoscopy. In South China there has been an increase in pediatric patients diagnosed with IBD over the past decade. However, a large epidemiological study is needed to confirm our findings.

  4. Barriers and Facilitators to Colorectal Cancer Screening in Vietnamese Americans: A Qualitative Analysis

    PubMed Central

    Kimura, Amanda; Sin, Mo-Kyung; Spigner, Clarence; Tran, Anh; Tu, Shin-Ping

    2015-01-01

    Background Vietnamese Americans are the fourth largest Asian ethnic group in the United States. Colorectal cancer (CRC) ranks as one of the most common cancers in Vietnamese Americans. However, CRC screening rates remain low among Vietnamese Americans, with 40% of women and 60% of men reporting never having a sigmoidoscopy, colonoscopy, or Fecal Occult Blood Test. Methods We partnered with a Federally Qualified Health Center (FQHC) in Seattle, Washington, to conduct focus groups as part of a process evaluation. Using interpreters, we recruited and conducted three focus groups comprised of 6 women screened for CRC, 6 women not screened for CRC, and 7 men screened for CRC, which made up a total of 19 FQHC patients of Vietnamese descent between 50 and 79 years old. Three team members analyzed transcripts using open coding and axial coding. Major themes were categorized into barriers and facilitators to CRC screening. Results Barriers include lack of health problems, having comorbidities, challenges with medical terminology, and concerns with the colonoscopy. Participants singled out the risk of perforation as a fear they have towards colonoscopy procedures. Facilitators include knowledge about CRC and CRC screening, access to sources of information and social networks, and physician recommendation. Conclusion Our focus groups elicited information that adds to the literature and has not been previously captured through published surveys. Findings from this study can be used to develop more culturally appropriate CRC screening interventions and improve upon existing CRC screening programs for the Vietnamese American population. PMID:24756545

  5. Cultural, economic, and psychological predictors of colonoscopy in a national sample.

    PubMed

    Halbert, Chanita Hughes; Barg, Frances K; Guerra, Carmen E; Shea, Judy A; Armstrong, Katrina; Ferguson, Monica; Weathers, Benita; Coyne, James; Troxel, Andrea B

    2011-11-01

    Although colorectal cancer (CRC) is the second leading cause of cancer death among adults in the US and colonoscopy is efficacious in reducing morbidity and mortality from CRC, screening rates are sub-optimal. Understanding the socioeconomic, cultural, and health care context within which decisions about colonoscopy are made allows physicians to address patients' most salient beliefs and values and other constraints when making screening recommendations. To evaluate the direct and interactive effects of socioeconomics, health care variables, psychological characteristics, and cultural values on colonoscopy use. National survey completed between January-August 2009 in a random sample of African American, white, and Hispanic adults ages 50-75 without cancer (n = 582). Self-reported colonoscopy use. Only 59% of respondents reported having a colonoscopy. The likelihood of colonoscopy increased with having health insurance (OR = 2.82, 95% CI = 1.24, 6.43, p = 0.004), and increasing age (OR = 1.40, 95% CI = 1.11, 1.77, p = 0.001). In addition, respondents with greater self-efficacy were more likely to have a colonoscopy (OR = 2.41, 95% CI = 1.35, 4.29, p = 0.003). Programs that help patients to overcome access and psychological barriers to screening are needed.

  6. Stool consistency and stool frequency are excellent clinical markers for adequate colon preparation after polyethylene glycol 3350 cleansing protocol: a prospective clinical study in children.

    PubMed

    Safder, Shaista; Demintieva, Yulia; Rewalt, Mary; Elitsur, Yoram

    2008-12-01

    Colon preparation for a colonoscopy in children is a difficult task because of the unpalatable taste and large volume of cleansing solution that needs to be consumed to ensure a clean colon. Consequently, an unprepared colon frequently occurs in routine practices, which causes early termination and a repeated procedure. (1) To assess the effectiveness of polyethylene glycol solution (PEG 3350) in preparing the colon of children scheduled for a colonoscopy and (2) to investigate clinical markers associated with an adequate colon preparation before a colonoscopy. A total of 167 children scheduled for a colonoscopy. In a prospective study, children scheduled for a colonoscopy were given PEG 3350 solution (1.5 g/kg per day, up to 100 g/d) over a 4-day preparation period. Each day, a simple questionnaire that documents the amount of liquid consumed, adverse effects, and the number and consistency of stool was completed by the parents. After a colonoscopy procedure, the colon preparation was assigned a number grade. The data were later assessed and were compared to determine the association between the grade of cleansing and the frequency and/or consistency of stool during preparation. Colon preparation was completed in 149 children, 133 of whom were adequately prepared. Inadequate preparation was found in 16 children; the procedure was terminated prematurely in 2 of these patients because of unacceptable conditions. No significant adverse effects were noted. A number of >or=5 stools/d, and liquid stool consistency in the last 2 days of preparation were associated with adequate colon preparation. PEG 3350 solution is safe, efficacious, and tolerable for children. Stool frequency and consistency in the last 2 days of preparation were excellent markers (positive predictive value 91%-95%), which predict an adequately clean colon before a colonoscopy in children.

  7. Image-based path planning for automated virtual colonoscopy navigation

    NASA Astrophysics Data System (ADS)

    Hong, Wei

    2008-03-01

    Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.

  8. Understanding intention to undergo colonoscopy among intermediate-risk siblings of colorectal cancer patients: a test of a mediational model.

    PubMed

    Manne, Sharon; Markowitz, Arnold; Winawer, Sidney; Guillem, Jose; Meropol, Neal J; Haller, Daniel; Jandorf, Lina; Rakowski, William; Babb, James; Duncan, Terry

    2003-01-01

    There is a need for research to identify factors influencing intentions to undergo colorectal cancer (CRC) screening among family members at risk for CRC. This study tested a mediational model primarily guided by Ronis' elaboration of the Health Belief Model in predicting intention to have colorectal cancer screening among siblings of individuals diagnosed with colorectal cancer prior to age 56 years. Data were collected from 534 siblings of individuals diagnosed with CRC. A baseline survey was administered by telephone. Measures included perceived susceptibility, CRC severity, physician and family support for CRC screening, cancer-specific distress, the closeness of the relationship with the affected sibling, and future intention to have a colonoscopy. Participant age, gender, and number of prior colonoscopies, as well as the stage of the affected patient's cancer and time from the patient's diagnosis to the interview, were controlled for in the analyses. The proposed model was not a good fit to the data. A respecified model was fit to the data. In this model, physician support, family support, and sibling closeness were significantly associated with both perceived benefits and barriers. Perceived severity was associated with barriers. Benefits and barriers, as well as cancer-specific distress, were directly associated with colonoscopy intentions. Results were consistent with a mediational role for benefits and barriers in the associations of sibling closeness and with a mediational role for barriers in the association between perceived severity and colonoscopy intentions. Family and physician support impacted intentions both directly and indirectly through effects on benefits and barriers. Perceived risk was not associated with benefits, barriers, or colonoscopy intentions. Intervention efforts to increase colonoscopy intentions may benefit from targeting family influences, particularly the affected proband in the family, as well as physician influence, cancer-related distress, perceived CRC severity, and perceived benefits and barriers to colonoscopy.

  9. Parameters of Glucose and Lipid Metabolism Affect the Occurrence of Colorectal Adenomas Detected by Surveillance Colonoscopies

    PubMed Central

    Kim, Nam Hee; Suh, Jung Yul; Park, Jung Ho; Park, Dong Il; Cho, Yong Kyun; Sohn, Chong Il; Choi, Kyuyong

    2017-01-01

    Purpose Limited data are available regarding the associations between parameters of glucose and lipid metabolism and the occurrence of metachronous adenomas. We investigated whether these parameters affect the occurrence of adenomas detected on surveillance colonoscopy. Materials and Methods This longitudinal study was performed on 5289 subjects who underwent follow-up colonoscopy between 2012 and 2013 among 62171 asymptomatic subjects who underwent an initial colonoscopy for a health check-up between 2010 and 2011. The risk of adenoma occurrence was assessed using Cox proportional hazards modeling. Results The mean interval between the initial and follow-up colonoscopy was 2.2±0.6 years. The occurrence of adenomas detected by the follow-up colonoscopy increased linearly with the increasing quartiles of fasting glucose, hemoglobin A1c (HbA1c), insulin, homeostasis model assessment of insulin resistance (HOMA-IR), and triglycerides measured at the initial colonoscopy. These associations persisted after adjusting for confounding factors. The adjusted hazard ratios for adenoma occurrence comparing the fourth with the first quartiles of fasting glucose, HbA1c, insulin, HOMA-IR, and triglycerides were 1.50 [95% confidence interval (CI), 1.26–1.77; ptrend<0.001], 1.22 (95% CI, 1.04–1.43; ptrend=0.024), 1.22 (95% CI, 1.02–1.46; ptrend=0.046), 1.36 (95% CI, 1.14–1.63; ptrend=0.004), and 1.19 (95% CI, 0.99–1.42; ptrend=0.041), respectively. In addition, increasing quartiles of low-density lipoprotein-cholesterol and apolipoprotein B were associated with an increasing occurrence of adenomas. Conclusion The levels of parameters of glucose and lipid metabolism were significantly associated with the occurrence of adenomas detected on surveillance colonoscopy. Improving the parameters of glucose and lipid metabolism through lifestyle changes or medications may be helpful in preventing metachronous adenomas. PMID:28120565

  10. Colonic gas explosion during therapeutic colonoscopy with electrocautery

    PubMed Central

    Ladas, Spiros D; Karamanolis, George; Ben-Soussan, Emmanuel

    2007-01-01

    Therapeutic colonoscopy with electrocautery is widely used around the world. Adequate colonic cleansing is considered a crucial factor for the safety of this procedure. Colonic gas explosion, although rare, is one of the most frightening iatrogenic complications during colonoscopy with electrocautery. This complication is the result of an accumulation of colonic gases to explosive concentrations, but may be prevented by meticulous bowel preparation. The purpose of this review is to discuss the indications and the types of bowel preparations for therapeutic colonoscopy, and to contribute recommendations for the adequate bowel preparation for colonoscopy with electrocautery. PMID:17879396

  11. Screening colonoscopy participation in Turkish colorectal cancer patients and their first degree relatives.

    PubMed

    Kilickap, Saadettin; Arslan, Cagatay; Rama, Dorina; Yalcin, Suayib

    2012-01-01

    This study aimed to research the awareness of screening colonoscopy (SC) among patients with colorectal cancer (CRC) and their relatives. A questionnaire form including information and behavior about colonoscopic screening for CRCs of patients and their first-degree relatives (FDRs) was prepared. A total of 406 CRC patients were enrolled into the study, with 1534 FDRs (siblings n: 1381 and parents n: 153) . Positive family history for CRC was found in 12% of the study population. Previous SC was performed in 11% of patients with CRC. Mean age of the patients whose FDRs underwent SC was lower than the patients whose FDRs did not (52 vs 57 years; p<0,001). The frequency of SC in FDRs was 64% in patients diagnosed CRC under 35 years of age. Persons having a positive family history of CRC had SC more often (51 vs 22%, p<0,001). FDRs of patients having a higher educational level and income had SC more frequently. When screening for CRC is planned, elderly subjects, those with family history for CRC, and those with low educational and lower income should be given especial attention in order that they be convinced to undergo screening for CRC.

  12. [Revision of Quality Indicators for the Endoscopy Quality Improvement Program of the National Cancer Screening Program in Korea].

    PubMed

    Min, Jun Ki; Cha, Jae Myung; Cho, Yu Kyung; Kim, Jie Hyun; Yoon, Soon Man; Im, Jong Pil; Jung, Yunho; Moon, Jeong Seop; Kim, Jin Oh; Jeen, Yoon Tae

    2018-05-25

    Gastroscopy and colonoscopy are widely used for the early diagnosis of stomach and colorectal cancer. The present revision integrates recent data regarding previous quality indicators and novel indicators suggested for gastroscopy and colonoscopy procedures for the National Cancer Screening Program in Korea. The new indicators, developed by the Quality Improvement Committee of the Korean Society for Gastrointestinal Endoscopy, vary in the level of supporting evidence, and most are based solely on expert opinion. Updated indicators validated by clinical research were prioritized, but were chosen by expert consensus when such studies were absent. The resultant quality indicators were graded according to the levels of consensus and recommendations. The updated indicators will provide a relevant guideline for high-quality endoscopy. The future direction of quality indicator development should include relevant outcome measures and an evidence-based approach to support proposed performance targets.

  13. Differences in Colonoscopy Quality Among Facilities: Development of a Post-Colonoscopy Risk-Standardized Rate of Unplanned Hospital Visits.

    PubMed

    Ranasinghe, Isuru; Parzynski, Craig S; Searfoss, Rana; Montague, Julia; Lin, Zhenqiu; Allen, John; Vender, Ronald; Bhat, Kanchana; Ross, Joseph S; Bernheim, Susannah; Krumholz, Harlan M; Drye, Elizabeth E

    2016-01-01

    Colonoscopy is a common procedure, yet little is known about variations in colonoscopy quality among outpatient facilities. We developed an outcome measure to profile outpatient facilities by estimating risk-standardized rates of unplanned hospital visits within 7 days of colonoscopy. We used a 20% sample of 2010 Medicare outpatient colonoscopy claims (331,880 colonoscopies performed at 8140 facilities) from patients ≥65 years or older, and developed a patient-level logistic regression model to estimate the risk of unplanned hospital visits (ie, emergency department visits, observation stays, and inpatient admissions) within 7 days of colonoscopy. We then used the patient-level risk model variables and hierarchical logistic regression to estimate facility rates of risk-standardized unplanned hospital visits using data from the Healthcare Cost and Utilization Project (325,811 colonoscopies at 992 facilities), from 4 states containing 100% of colonoscopies per facility. Outpatient colonoscopies were followed by 5412 unplanned hospital visits within 7 days (16.3/1000 colonoscopies). Hemorrhage, abdominal pain, and perforation were the most common causes of unplanned hospital visits. Fifteen variables were independently associated with unplanned hospital visits (c = 0.67). A history of fluid and electrolyte imbalance (odds ratio [OR] = 1.43; 95% confidence interval [CI]: 1.29-1.58), psychiatric disorders (OR = 1.34; 95% CI: 1.22-1.46), and, in the absence of prior arrhythmia, increasing age past 65 years (aged >85 years vs 65-69 years: OR = 1.87; 95% CI: 1.54-2.28) were most strongly associated. The facility risk-standardized unplanned hospital visits calculated using Healthcare Cost and Utilization Project data showed significant variation (median 12.3/1000; 5th-95th percentile, 10.5-14.6/1000). Median risk-standardized unplanned hospital visits were comparable between ambulatory surgery centers and hospital outpatient departments (each was 10.2/1000), and ranged from 16.1/1000 in the Northeast to 17.2/1000 in the Midwest. We calculated a risk-adjusted measure of outpatient colonoscopy quality, which shows important variation in quality among outpatient facilities. This measure can make transparent the extent to which patients require follow-up hospital care, help inform patient choices, and assist in quality-improvement efforts. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  14. Colorectal Cancer

    MedlinePlus

    ... be detected by optical colonoscopy. Virtual colonoscopy uses virtual reality technology to produce three-dimensional images of the colon and rectum. However, the costs and benefits of virtual colonoscopy are still being investigated, and the technique ...

  15. Dietary patterns and risk of advanced colorectal neoplasms: A large population based screening study in Germany.

    PubMed

    Erben, Vanessa; Carr, Prudence R; Holleczek, Bernd; Stegmaier, Christa; Hoffmeister, Michael; Brenner, Hermann

    2018-06-01

    Specific components of the diet such as red and processed meat have been associated with the risk of developing colorectal cancer. However, evidence on the association of dietary patterns with colorectal neoplasms is sparse. The aim of this study was to analyze the association of dietary patterns with prevalence of advanced colorectal neoplasms among older adults in Germany. A cross-sectional study was conducted among participants of screening colonoscopy in Saarland, Germany, who were enrolled in the KolosSal study (Effektivität der Früherkennungs-Koloskopie: eine Saarland-weite Studie) from 2005 to 2013. Information on diet and lifestyle factors was obtained through questionnaires and colonoscopy results were extracted from physicians' reports. Associations of a priori defined dietary patterns (vegetarian or adapted versions of the Healthy Eating Index [HEI] and the Dietary Approaches to Stop Hypertension [DASH] index) with the risk of advanced colorectal neoplasms were assessed by multiple logistic regression analyses with comprehensive adjustment for potential confounders. A total of 14,309 participants were included (1561 with advanced colorectal neoplasms). Healthier eating behavior was associated with lower prevalence of advanced colorectal neoplasms in a dose-response manner. Adjusted odds ratios (95% confidence intervals) comparing the highest with the lowest categories of adapted HEI and DASH were 0.61 (0.50, 0.76) and 0.70 (0.55, 0.89), respectively. No significant associations were observed for a vegetarian eating pattern (adjusted OR 0.80 (0.55, 1.17)). Healthy dietary patterns, as described by a high HEI or DASH score, but not a vegetarian diet alone, are associated with reduced risk of advanced colorectal neoplasms. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Metachronous colon polyps in younger versus older adults: a case-control study.

    PubMed

    Nagpal, Sajan Jiv Singh; Mukhija, Dhruvika; Sanaka, Madhusudhan; Lopez, Rocio; Burke, Carol A

    2018-03-01

    The incidence of colorectal cancer in the United States has decreased substantially in individuals aged 50 and older. In contrast, it is increasing in young adults. The polyp characteristics on baseline and follow-up colonoscopy in young adults are not well characterized. We describe the polyp characteristics on baseline and follow-up colonoscopy in adults <40 years and determined factors associated with the occurrence of metachronous, advanced neoplasia or high-risk (HR) polyp features. We compared the occurrence of metachronous advanced neoplasia in young adults with those 50 years and older to assess whether postpolypectomy surveillance guidelines seem appropriate for polyp-bearing adults less than age 40 years. Patients <40 years of age with >1 polyp removed on colonoscopy followed by a postpolypectomy colonoscopy were eligible. The primary outcome was the occurrence of advanced neoplasia or HR polyp features on follow-up colonoscopy. Secondary endpoints included factors associated with metachronous advanced neoplasia in young adults. The occurrence of metachronous advanced neoplasia in young adults was compared with a cohort of patients aged 50 years and older. Included were 128 patients with a mean age of 34.9 years; 124 patients (97%) had adenomas and 7% had sessile serrated polyps (SSPs). Advanced neoplasia was seen in 35% of patients at baseline. The median follow-up time was 33.6 months. Metachronous advanced neoplasia was identified in 7% of patients on follow-up colonoscopy. Baseline factors associated with metachronous advanced neoplasia included the presence of an SSP (hazard ratio, 7.8; 95% CI, 1.09-56.3; P = .041) with a trend in those with advanced neoplasia (hazard ratio, 3.4; 95% confidence interval, .89-12.8; P = .072). The occurrence of metachronous advanced neoplasia did not differ between the young and older cohorts (7% vs 12.2%, P = .58); however, young adults were less likely to have HR polyp features on follow-up (8.6% vs 20.3%, P = .008). More than 1 in 3 adults <40 years old undergoing colonoscopy had advanced neoplasia on baseline colonoscopy. The occurrence of metachronous advanced neoplasia in young adults is similar to older adults and appears to be associated with the size, pathology, and number of baseline polyps. Our data suggest young polyp-bearing adults may undergo postpolypectomy colonoscopy at intervals currently recommended by national guidelines. Confirmation in larger studies is warranted. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  17. Tolerance, effectiveness, and acceptability of sulfate-free electrolyte lavage solution for colon cleaning before colonoscopy.

    PubMed

    Raymond, J M; Beyssac, R; Capdenat, E; Pineau, C H; Kerjean, A; Saux, M C; Couzigou, P; Amouretti, M

    1996-09-01

    The unpleasant taste of the solution used for preparation before colonoscopy may limit patients' compliance with the procedure. However, the published results concerning the acceptability of sulfate-free electrolyte lavage solution (SF-ELS) for colon cleansing before colonoscopy are conflicting. The aim of this study was to compare SF-ELS with the standard polyethylene glycol (PEG) solution with regard to tolerance, effectiveness, and acceptability. In the first part of the study, 24 patients were assigned to receive either one liter of SF-ELS or one liter of the standard PEG solution. After two hours, the patients had to choose two further liters (of either the first or second solution), and preparation for colonoscopy was completed. In the second part, fifty further patients were randomized into two groups: 25 patients received four liters of standard solution, and 25 patients received four liters of SF-ELS. The patients' opinions regarding the preparation and their willingness to repeat the use of the same preparation were recorded by questionnaire. The quality of the colon preparation was assessed by the endoscopists. Seventeen patients (71%; P < 0.05) preferred SF-ELS. The compliance rate in the two groups was 96%, and the frequency of occurrence of adverse effects was also similar. Colonoscopy was completed in 24 of the 25 patients in the SF-ELS group and 22 of the 25 patients in the standard PEG group (the difference was not significant). Visualization of the mucosa in the areas explored was perfect in 20 of the 25 patients in the SF-ELS group and in 17 of the 25 patients in the PEG group (not significant). Patients had a significant preference for SF-ELS. Eighteen of the 25 patients in the SF-ELS group were willing to accept the same preparation for a further colonoscopy, compared with 11 of the 25 in the other group (P < 0.05). Improving the acceptability of colonic preparation before colonoscopy could improve patients' compliance and the quality of the follow-up. The results of this study justify further investigation of SF-ELS.

  18. The cost-effectiveness of screening for colorectal cancer.

    PubMed

    Telford, Jennifer J; Levy, Adrian R; Sambrook, Jennifer C; Zou, Denise; Enns, Robert A

    2010-09-07

    Published decision analyses show that screening for colorectal cancer is cost-effective. However, because of the number of tests available, the optimal screening strategy in Canada is unknown. We estimated the incremental cost-effectiveness of 10 strategies for colorectal cancer screening, as well as no screening, incorporating quality of life, noncompliance and data on the costs and benefits of chemotherapy. We used a probabilistic Markov model to estimate the costs and quality-adjusted life expectancy of 50-year-old average-risk Canadians without screening and with screening by each test. We populated the model with data from the published literature. We calculated costs from the perspective of a third-party payer, with inflation to 2007 Canadian dollars. Of the 10 strategies considered, we focused on three tests currently being used for population screening in some Canadian provinces: low-sensitivity guaiac fecal occult blood test, performed annually; fecal immunochemical test, performed annually; and colonoscopy, performed every 10 years. These strategies reduced the incidence of colorectal cancer by 44%, 65% and 81%, and mortality by 55%, 74% and 83%, respectively, compared with no screening. These strategies generated incremental cost-effectiveness ratios of $9159, $611 and $6133 per quality-adjusted life year, respectively. The findings were robust to probabilistic sensitivity analysis. Colonoscopy every 10 years yielded the greatest net health benefit. Screening for colorectal cancer is cost-effective over conventional levels of willingness to pay. Annual high-sensitivity fecal occult blood testing, such as a fecal immunochemical test, or colonoscopy every 10 years offer the best value for the money in Canada.

  19. Queue position in the endoscopic schedule impacts effectiveness of colonoscopy.

    PubMed

    Lee, Alexander; Iskander, John M; Gupta, Nitin; Borg, Brian B; Zuckerman, Gary; Banerjee, Bhaskar; Gyawali, C Prakash

    2011-08-01

    Endoscopist fatigue potentially impacts colonoscopy. Fatigue is difficult to quantitate, but polyp detection rates between non-fatigued and fatigued time periods could represent a surrogate marker. We assessed whether timing variables impacted polyp detection rates at a busy tertiary care endoscopy suite. Consecutive patients undergoing colonoscopy were retrospectively identified. Indications, clinical demographics, pre-procedural, and procedural variables were extracted from chart review; colonoscopy findings were determined from the procedure reports. Three separate timing variables were assessed as surrogate markers for endoscopist fatigue: morning vs. afternoon procedures, start times throughout the day, and queue position, a unique variable that takes into account the number of procedures performed before the colonoscopy of interest. Univariate and multivariate analyses were performed to determine whether timing variables and other clinical, pre-procedural, and procedural variables predicted polyp detection. During the 4-month study period, 1,083 outpatient colonoscopy procedures (57.5±0.5 years, 59.5% female) were identified, performed by 28 endoscopists (mean 38.7 procedures/endoscopist), with a mean polyp detection rate of 0.851/colonoscopy. At least, one adenoma was detected in 297 procedures (27.4%). A 12.4% reduction in mean detected polyps was detected between morning and afternoon procedures (0.90±0.06 vs. 0.76±0.06, P=0.15). Using start time on a continuous scale, however, each elapsed hour in the day was associated with a 4.6% reduction in polyp detection (P=0.005). When queue position was assessed, a 5.4% reduction in polyp detection was noted with each increase in queue position (P=0.016). These results remained significant when controlled for each individual endoscopist. Polyp detection rates decline as time passes during an endoscopist's schedule, potentially from endoscopist fatigue. Queue position may be a novel surrogate measure for operator fatigue.

  20. Validity of data in the Danish Colorectal Cancer Screening Database.

    PubMed

    Thomsen, Mette Kielsholm; Njor, Sisse Helle; Rasmussen, Morten; Linnemann, Dorte; Andersen, Berit; Baatrup, Gunnar; Friis-Hansen, Lennart Jan; Jørgensen, Jens Christian Riis; Mikkelsen, Ellen Margrethe

    2017-01-01

    In Denmark, a nationwide screening program for colorectal cancer was implemented in March 2014. Along with this, a clinical database for program monitoring and research purposes was established. The aim of this study was to estimate the agreement and validity of diagnosis and procedure codes in the Danish Colorectal Cancer Screening Database (DCCSD). All individuals with a positive immunochemical fecal occult blood test (iFOBT) result who were invited to screening in the first 3 months since program initiation were identified. From these, a sample of 150 individuals was selected using stratified random sampling by age, gender and region of residence. Data from the DCCSD were compared with data from hospital records, which were used as the reference. Agreement, sensitivity, specificity and positive and negative predictive values were estimated for categories of codes "clean colon", "colonoscopy performed", "overall completeness of colonoscopy", "incomplete colonoscopy", "polypectomy", "tumor tissue left behind", "number of polyps", "lost polyps", "risk group of polyps" and "colorectal cancer and polyps/benign tumor". Hospital records were available for 136 individuals. Agreement was highest for "colorectal cancer" (97.1%) and lowest for "lost polyps" (88.2%). Sensitivity varied between moderate and high, with 60.0% for "incomplete colonoscopy" and 98.5% for "colonoscopy performed". Specificity was 92.7% or above, except for the categories "colonoscopy performed" and "overall completeness of colonoscopy", where the specificity was low; however, the estimates were imprecise. A high level of agreement between categories of codes in DCCSD and hospital records indicates that DCCSD reflects the hospital records well. Further, the validity of the categories of codes varied from moderate to high. Thus, the DCCSD may be a valuable data source for future research on colorectal cancer screening.

  1. Factors Associated with Anxiety About Colonoscopy: The Preparation, the Procedure, and the Anticipated Findings.

    PubMed

    Shafer, L A; Walker, J R; Waldman, C; Yang, C; Michaud, V; Bernstein, C N; Hathout, L; Park, J; Sisler, J; Restall, G; Wittmeier, K; Singh, H

    2018-03-01

    Previous research has assessed anxiety around colonoscopy procedures, but has not considered anxiety related to different aspects related to the colonoscopy process. Before colonoscopy, we assessed anxiety about: bowel preparation, the procedure, and the anticipated results. We evaluated associations between patient characteristics and anxiety in each area. An anonymous survey was distributed to patients immediately prior to their outpatient colonoscopy in six hospitals and two ambulatory care centers in Winnipeg, Canada. Anxiety was assessed using a visual analog scale. For each aspect, logistic regression models were used to explore associations between patient characteristics and high anxiety. A total of 1316 respondents completed the questions about anxiety (52% female, median age 56 years). Anxiety scores > 70 (high anxiety) were reported by 18% about bowel preparation, 29% about the procedure, and 28% about the procedure results. High anxiety about bowel preparation was associated with female sex, perceived unclear instructions, unfinished laxative, and no previous colonoscopies. High anxiety about the procedure was associated with female sex, no previous colonoscopies, and confusing instructions. High anxiety about the results was associated with symptoms as an indication for colonoscopy and instructions perceived as confusing. Fewer people had high anxiety about preparation than about the procedure and findings of the procedure. There are unique predictors of anxiety about each colonoscopy aspect. Understanding the nuanced differences in aspects of anxiety may help to design strategies to reduce anxiety, leading to improved acceptance of the procedure, compliance with preparation instructions, and less discomfort with the procedure.

  2. Technological advances for improving adenoma detection rates: The changing face of colonoscopy.

    PubMed

    Ishaq, Sauid; Siau, Keith; Harrison, Elizabeth; Tontini, Gian Eugenio; Hoffman, Arthur; Gross, Seth; Kiesslich, Ralf; Neumann, Helmut

    2017-07-01

    Worldwide, colorectal cancer is the third commonest cancer. Over 90% follow an adenoma-to-cancer sequence over many years. Colonoscopy is the gold standard method for cancer screening and early adenoma detection. However, considerable variation exists between endoscopists' detection rates. This review considers the effects of different endoscopic techniques on adenoma detection. Two areas of technological interest were considered: (1) optical technologies and (2) mechanical technologies. Optical solutions, including FICE, NBI, i-SCAN and high definition colonoscopy showed mixed results. In contrast, mechanical advances, such as cap-assisted colonoscopy, FUSE, EndoCuff and G-EYE™, showed promise, with reported detections rates of up to 69%. However, before definitive recommendations can be made for their incorporation into daily practice, further studies and comparison trials are required. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corcillo, Antonella, E-mail: antonella.corcillo@chuv.ch; Aellen, Steve, E-mail: steve.aellen@hopitalvs.ch; Zingg, Tobias

    Purpose: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. Methods: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reportedmore » case of PSAE) was performed and the three types of treatment compared. Results: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. Conclusion: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic ruptures after colonoscopy in hemodynamically stabilized patients.« less

  4. Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.

    PubMed

    Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-06-01

    Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is provided. Although CLIC items relate to colonoscopy, the development process we detail can be used to adapt the instrument for use in other learning settings in medical education. © 2016 John Wiley & Sons Ltd.

  5. Can Technology Improve the Quality of Colonoscopy?

    PubMed

    Thirumurthi, Selvi; Ross, William A; Raju, Gottumukkala S

    2016-07-01

    In order for screening colonoscopy to be an effective tool in reducing colon cancer incidence, exams must be performed in a high-quality manner. Quality metrics have been presented by gastroenterology societies and now include higher adenoma detection rate targets than in the past. In many cases, the quality of colonoscopy can often be improved with simple low-cost interventions such as improved procedure technique, implementing split-dose bowel prep, and monitoring individuals' performances. Emerging technology has expanded our field of view and image quality during colonoscopy. We will critically review several technological advances in the context of quality metrics and discuss if technology can really improve the quality of colonoscopy.

  6. Optimizing bowel preparation for colonoscopy: a guide to enhance quality of visualization

    PubMed Central

    Bechtold, Matthew L.; Mir, Fazia; Puli, Srinivas R.; Nguyen, Douglas L.

    2016-01-01

    Colonoscopy is an important screening and therapeutic modality for colorectal cancer. Unlike other screening tests, colonoscopy is dependent on pre-procedure bowel preparation. If the bowel preparation is poor, significant pathology may be missed. Many factors are known to improve bowel preparation. This review will highlight those factors that may optimize the bowel preparation, including choice of bowel preparation, grading or scoring of the bowel preparation, special factors that influence preparation, and diet prior to colonoscopy that affects bowel preparation. The aim of the review is to offer suggestions and guide endoscopists on how to optimize the bowel preparation for the patients undergoing colonoscopy. PMID:27065725

  7. Using segmented regression analysis of interrupted time series data to assess colonoscopy quality outcomes of a web-enhanced implementation toolkit to support evidence-based practices for bowel preparation: a study protocol.

    PubMed

    Ramsey, Alex T; Maki, Julia; Prusaczyk, Beth; Yan, Yan; Wang, Jean; Lobb, Rebecca

    2015-06-07

    While there is convincing evidence on interventions to improve bowel preparation for patients, the evidence on how to implement these evidence-based practices (EBPs) in outpatient colonoscopy settings is less certain. The Strategies to Improve Colonoscopy (STIC) study compares the effect of two implementation strategies, physician education alone versus physician education plus an implementation toolkit for staff, on adoption of three EBPs (split-dosing of bowel preparation, low-literacy education, teach-back) to improve pre-procedure and intra-procedure quality measures. The implementation toolkit contains a staff education module, website containing tools to support staff in delivering EBPs, tailored patient education materials, and brief consultation with staff to determine how the EBPs can be integrated into the existing workflow. Given adaptations to the implementation plan and intentional flexibility in the delivery of the EBPs, we utilize a pragmatic study to balance external validity with demonstrating effectiveness of the implementation strategies. Participants will include all outpatient colonoscopy physicians, staff, and patients from a convenience sample of six endoscopy settings. Aim #1 will explore the relative effect of two strategies to implement patient-level EBPs on adoption and clinical quality outcomes. We will assess the change in level and trends of clinical quality outcomes (i.e., adequacy of bowel preparation, adenoma detection) using segmented regression analysis of interrupted time series data with two groups (intervention and delayed start). Aim #2 will examine the influence of organizational readiness to change on EBP implementation. We use a PRECIS diagram to reflect the extent to which each indicator of the study was pragmatic versus explanatory, revealing a largely pragmatic study. Implementation challenges have already motivated several adaptations to the original plan, reflecting the nature of implementation in real-world healthcare settings. The pragmatic study responds to the evolving needs of its healthcare partners and allows for flexibility in intervention delivery, thereby informing clinical decision-making in real-world settings. The current study will provide information about what works (intervention effectiveness), for whom it works (influence of Medicaid versus other insurance), in which contexts it works (setting characteristics that influence implementation), and how it works best (comparison of implementation strategies).

  8. The effect of auricular acupuncture on pain during colonoscopy with midazolam and pethidine

    NASA Astrophysics Data System (ADS)

    Kusumastuti, R.; Srilestari, A.; Abdurrohim, K.; Abdullah, M.

    2017-08-01

    Colonoscopy is the standard procedure for colorectal cancer screening. One of its common complications is abdominal pain. Analgesia has not provided favorable outcomes so various complementary practices have been developed, including auricular acupuncture. In this study, a randomized controlled trial of 56 patients who underwent colonoscopy was conducted to determine the effect of acupuncture on the pain experienced during colonoscopy. Subjects were divided into two groups: The first received acupuncture combined with midazolam and pethidine, while the second were administered placebo puncture in addition to midazolam and pethidine. The median Critical Care Pain Observation Tool (CPOT) score was lower in the auricular acupuncture group than in the placebo puncture group(0.7 [0-4.83] vs. 1.9 [0-6.20] p = 0.010), while there were no significant differences to median Visual Analog Scale (VAS) scores (29 [0-100] vs. 44.5 [0-100] p = 0.147), heart rate changes (-2.58 [14.31] vs.-2.43 [12.28]; p = 0.970), or the mean time to the cecum (16 [8-51] vs. 22 [5-63] p = 0.206). Auricular acupuncture combined with midazolam and pethidine was found to be effective at reducing pain during colonoscopy.

  9. Two-day bowel preparation with polyethylene glycol 3350 and bisacodyl: a new, safe, and effective regimen for colonoscopy in children.

    PubMed

    Phatak, Uma P; Johnson, Susanne; Husain, Sohail Z; Pashankar, Dinesh S

    2011-07-01

    To assess the safety, efficacy, and acceptance of a 2-day bowel preparation with polyethylene glycol (PEG) 3350 without electrolytes and bisacodyl for colonoscopy in children. In a prospective study, 111 children of mean age 11.9 years were given 2 g/kg of PEG and a 5-mg tablet of bisacodyl daily for 2 days before colonoscopy. Stool frequency, consistency, and adverse effects were monitored for the duration of the bowel preparation. Compliance and quality of colonic preparation were assessed on the day of the colonoscopy. The average daily stool frequency increased from a baseline of 2, to 4* on day 1, and 6.5* on day 2 of the bowel preparation (*P < 0.001 for difference vs baseline). The colonic preparations were rated as excellent or good in 92% and 93% of the patients in the right and left colon, respectively. Adverse effects were mild nausea (19%), abdominal pain (11%), and vomiting (4%). The compliance was rated as excellent in 95% of the patients. A 2-day bowel preparation with PEG and bisacodyl is safe, effective, and well accepted for colonoscopy in children without any major adverse effects.

  10. Virtual reality colonoscopy simulation: a compulsory practice for the future colonoscopist?

    PubMed

    Ahlberg, G; Hultcrantz, R; Jaramillo, E; Lindblom, A; Arvidsson, D

    2005-12-01

    As for any manual procedure, the learning curves for medical interventions can have undesirable phases, occurring mostly in the early experience of applying a technique. There have been impressive advances in endoscopic procedures during recent years, and there is an emerging trend that the number of procedures is increasing in parallel with these. In addition, the introduction of screening programs for colorectal cancer will also increase the numbers of procedures needed. Recent developments in medical simulation seem promising with regard to the possibility of "training out" undesirable parts of the learning curve outside the operating room. The aim of this study was to investigate whether the use of the AccuTouch flexible endoscopy simulator improves the early part of the learning curve in colonoscopy training. 12 endoscopy trainees, 10 surgeons and two medical gastroenterologists, all with experience in gastroscopy but with no specific colonoscopy experience, were randomly assigned to either simulator training or to a control group. They all received the same theoretical study package and the training group practiced with the AccuTouch colonoscopy simulator until a predefined expert level of performance was reached. All trainees performed their first ten individual colonoscopies described in detail in a separate protocol. Trainees in the simulator-trained group performed significantly better (P=0.0011) and managed to reach the cecum in 52% of their cases (vs. 19% in the control group), and were 4.53 times more likely to succeed compared with the controls. Additionally, there was a significantly shorter procedure time and less patient discomfort in the hands of the simulator-trained group. Skills acquired using the AccuTouch simulator transfer well into the clinical colonoscopy environment. The results of this trial clearly support the plan to integrate simulator training into endoscopic education curricula.

  11. Screening CT Colonography: Multicenter Survey of Patient Experience, Preference, and Potential Impact on Adherence

    PubMed Central

    Pooler, B. Dustin; Baumel, Mark J.; Cash, Brooks D.; Moawad, Fouad J.; Riddle, Mark S.; Patrick, Amy M.; Damiano, Mark; Lee, Matthew H.; Kim, David H.; del Rio, Alejandro Muñoz; Pickhardt, Perry J.

    2013-01-01

    OBJECTIVE Prior research indicates CT colonography (CTC) would be a cost-effective colorectal cancer (CRC) screening test if widespread availability were to increase overall CRC screening adherence rates. The primary aims of this multicenter study were to evaluate patient experience and satisfaction with CTC screening and compare preference against screening colonoscopy. MATERIALS AND METHODS A 12-question survey instrument measuring pretest choice, experience, and satisfaction was given to a consecutive cohort of adults undergoing CTC screening in three disparate screening settings: university academic center, military medical center, and community practice. The study cohort was composed of individuals voluntarily participating in clinical CTC screening programs. RESULTS A total of 1417 patients responded to the survey. The top reasons for choosing CTC for screening included “noninvasiveness” (68.0%), “avoidance of sedation/anesthesia” (63.1%), “ability to drive after the test” (49.2%), “avoidance of optical colonoscopy risks” (46.9%), and “identifying abnormalities outside the colon” (43.3%). Only 7.2% of patients reported pain during the CTC examination and only 2.5% reported greater than moderate discomfort. Of 441 patients who had experienced both CTC and optical colonoscopy, 77.1% preferred CTC and 13.8% preferred optical colonoscopy. Of all patients, 29.6% indicated that they may not have undergone optical colonoscopy screening if CTC were not available. Of all patients, 92.9% labeled their overall experience with CTC as “excellent” or “good,” and 93.0% indicated they would choose CTC for their next screening. CONCLUSION Respondents reported a very high satisfaction level with CTC, and those who had experienced both modalities indicated a preference for CTC over optical colonoscopy. These results suggest that CTC has the potential to increase adherence to CRC screening guidelines if widely available. PMID:22623549

  12. Controversies in colorectal cancer screening.

    PubMed

    Pox, Christian P

    2014-01-01

    Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.

  13. Colonoscopy: practice variation among 69 hospital-based endoscopists.

    PubMed

    Cotton, Peter B; Connor, Patrick; McGee, Daniel; Jowell, Paul; Nickl, Nick; Schutz, Steve; Leung, Joseph; Lee, John; Libby, Eric

    2003-03-01

    The medical profession, payers, and patients are interested increasingly in the quality of endoscopic procedures, including colonoscopy. The American Society for Gastrointestinal Endoscopy has recommended "report cards" by which endoscopists may keep track of certain key elements of their practice including indications, findings, duration, technical end points, complications, and patient satisfaction. The GI-Trac endoscopy reporting database includes many of the data points recommended by ASGE for report cards. Seven hospital centers in North America have been collecting data prospectively for varying periods since 1994. These data were aggregated and analyzed by individual endoscopist. A total of 69 endoscopists performed 17,868 colonoscopies. Twelve percent of the endoscopists reported that more than 20% of procedures they performed were completely normal. The average time taken by 27% of endoscopists was more than 40 minutes (without trainees involved), and only 55% achieved a cecal intubation rate of over 90%; for 9% the rate was less than 80%. Complication rates were too low for individual comparisons. These data provide an idea of colonoscopy performance by individual endoscopists in mainly academic centers. Incorporating all recommended data elements in future reporting databases will contribute to meaningful bench marking and to quality improvement efforts.

  14. Associations of dietary fat with risk of early neoplasia in the proximal colon in a population-based case-control study.

    PubMed

    Mo, Allen; Wu, Rong; Grady, James P; Hanley, Matthew P; Toro, Margaret; Swede, Helen; Devers, Thomas J; Hartman, Terryl J; Rosenberg, Daniel W

    2018-07-01

    Excess dietary fat consumption is strongly associated with the risk of colorectal cancer, but less is known about its role in the earliest stages of carcinogenesis, particularly within the proximal colon. In the following case-control study, we evaluated the relationship between the intake of dietary fats and the frequency of early proximal neoplasia [aberrant crypt foci (ACF) or polyps], detectable by high-definition colonoscopy with contrast dye-spray. Average-risk screening individuals underwent a high-definition colonoscopy procedure as part of larger ongoing clinical study of precancerous lesions in the proximal colon. Dietary fat intake was assessed using the Block Brief Food Frequency Questionnaire, which estimates average dietary intake based on 70 food items. The diets of individuals with no endoscopically identifiable lesions (n = 36) were compared to those with either ACF or polyps detected in the proximal colon. In multivariate analysis, high dietary intake of total polyunsaturated fatty acids (PUFAs) and intake of omega-6 and omega-3 fatty acids were positively associated with neoplastic lesions in the proximal colon. When comparing ACF and polyp groups separately, a positive association was observed for both proximal polyps (OR 2.28; CI 1.16-7.09) and ACF (OR 2.86; CI 1.16-7.09) for total PUFA intake. Furthermore, the prevalence of proximal ACF was increased with higher intake of omega-6 (OR 3.54; CI 1.32-9.47) and omega-3 fatty acids (OR 2.29; CI 1.02-5.13), although there was no discernible difference in the omega-6/omega-3 ratio. These results suggest that dietary PUFAs may be positively associated with risk of early neoplasia in the proximal colon. This study provides further evidence that dietary PUFA composition may play an important role in altering the microenvironment within the human colon.

  15. Early Prediction of Cancer Progression by Depth-Resolved Nanoscale Mapping of Nuclear Architecture from Unstained Tissue Specimens.

    PubMed

    Uttam, Shikhar; Pham, Hoa V; LaFace, Justin; Leibowitz, Brian; Yu, Jian; Brand, Randall E; Hartman, Douglas J; Liu, Yang

    2015-11-15

    Early cancer detection currently relies on screening the entire at-risk population, as with colonoscopy and mammography. Therefore, frequent, invasive surveillance of patients at risk for developing cancer carries financial, physical, and emotional burdens because clinicians lack tools to accurately predict which patients will actually progress into malignancy. Here, we present a new method to predict cancer progression risk via nanoscale nuclear architecture mapping (nanoNAM) of unstained tissue sections based on the intrinsic density alteration of nuclear structure rather than the amount of stain uptake. We demonstrate that nanoNAM detects a gradual increase in the density alteration of nuclear architecture during malignant transformation in animal models of colon carcinogenesis and in human patients with ulcerative colitis, even in tissue that appears histologically normal according to pathologists. We evaluated the ability of nanoNAM to predict "future" cancer progression in patients with ulcerative colitis who did and did not develop colon cancer up to 13 years after their initial colonoscopy. NanoNAM of the initial biopsies correctly classified 12 of 15 patients who eventually developed colon cancer and 15 of 18 who did not, with an overall accuracy of 85%. Taken together, our findings demonstrate great potential for nanoNAM in predicting cancer progression risk and suggest that further validation in a multicenter study with larger cohorts may eventually advance this method to become a routine clinical test. ©2015 American Association for Cancer Research.

  16. Physician-patient and patient-family communication after colonoscopy.

    PubMed

    Jiménez, Jessica A; Jung, Barbara; Madlensky, Lisa

    2012-09-01

    A personal or family history of colorectal adenomas increases the risk of colorectal cancer (CRC). We aimed to compare physicians' communication with polyp patients vs. non-polyp patients, assess whether polyps or CRC family history were associated with physician-patient communication, and describe patients' disclosure of colonoscopy and polyp diagnosis to their relatives. Four hundred nine patients completed an online survey regarding physician-patient communication of colonoscopy results, perceived personal and familial risk of polyps and CRC, and disclosure of colonoscopy results to relatives. Six percent of participants reported that their physicians discussed familial risks. Polyp diagnosis and family history predicted physician-patient discussions about familial CRC risks. Polyp diagnosis predicted physician-patient discussions of future surveillance. Twenty-two percent of patients told none of their relatives that they had a colonoscopy. Family history, gender, and education were associated with patient-family communication. There is room for improvement in physician-patient and patient-family communication following colonoscopy.

  17. Screening colonoscopy for the detection of neoplastic lesions in asymptomatic HIV-infected subjects.

    PubMed

    Bini, E J; Green, B; Poles, M A

    2009-08-01

    Although non-AIDS defining malignancies are rapidly increasing as HIV-infected subjects live longer, little is know about the results of screening for colonic neoplasms (adenomatous polyps and adenocarcinomas) in this population. We conducted a screening colonoscopy study to determine the prevalence of colonic neoplasms in 136 asymptomatic HIV-infected subjects >or=50 years of age and 272 asymptomatic uninfected control subjects matched for age, sex, and family history of colorectal cancer. Advanced neoplasms were defined as adenomas >or=10 mm or any adenoma, regardless of size, with villous histology, high-grade dysplasia, or adenocarcinoma. The prevalence of neoplastic lesions was significantly higher in HIV-infected subjects than in control subjects (62.5% vs 41.2%, p<0.001), and remained highly significant after adjustment for potential confounding variables (odds ratio = 3.00; 95% confidence interval, 1.83 to 4.93). Among patients with colorectal adenocarcinoma, HIV-infected subjects were significantly younger (52.4 (SD 1.3) vs 60.3 (SD 4.0) years, p = 0.002) and were more likely to have advanced cancers (stage III or IV) than control subjects (60.0% vs 16.7%, p = 0.24). Of HIV-infected subjects with advanced neoplasms proximal to the splenic flexure, distal neoplastic lesions were absent in 88.9% of individuals and these would have been missed by flexible sigmoidoscopy. HIV-infected subjects have a higher prevalence of colonic neoplasms, and adenocarcinomas develop at a younger age and are more advanced than in uninfected subjects. Our findings suggest that screening colonoscopy should be offered to HIV-infected subjects, but the age of initiation and the optimal frequency of screening require further study.

  18. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals.

    PubMed

    Kobaek-Larsen, M; Kroijer, R; Dyrvig, A-K; Buijs, M M; Steele, R J C; Qvist, N; Baatrup, G

    2018-06-01

    The aim was to determine the polyp detection rate and per-patient sensitivity for polyps > 9 mm of colon capsule endoscopy (CCE) compared with colonoscopy as well as the diagnostic accuracy of CCE. Individuals who had a positive immunochemical faecal occult blood test during screening had investigator blinded CCE and colonoscopy. Participants underwent repeat endoscopy if significant lesions detected by CCE were considered to have been missed by colonoscopy. There were 253 participants. The polyp detection rate was significantly higher in CCE compared with colonoscopy (P = 0.02). The per-patient sensitivity for > 9 mm polyps for CCE and colonoscopy was 87% (95% CI: 83-91%) and 88% (95% CI: 84-92%) respectively. In participants with complete CCE and colonoscopy examinations (N = 126), per-patient sensitivity of > 9 mm polyps in CCE (97%; 95% CI: 94-100%) was superior to colonoscopy (89%; 95% CI: 84-94%). A complete capsule endoscopy examination (N = 134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp > 10 mm or more than two polyps. CCE is superior to colonoscopy in polyp detection rate and per-patient sensitivity to > 9 mm polyps, but only in complete CCE examinations. The rate of incomplete CCE examinations must be improved. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  19. Pneumothorax, pneumomediastinum, pneumoperitoneum, pneumoretroperitoneum and subcutaneous emphysema following diagnostic colonoscopy.

    PubMed

    Marwan, K; Farmer, K C; Varley, C; Chapple, K S

    2007-07-01

    Colonic perforation is an unusual complication of colonoscopy. We present a case of pneumothorax, pneumomediastinum, pneumoperitoneum and extensive subcutaneous emphysema resulting from a diagnostic colonoscopy. To our knowledge, only two such cases have been described previously.

  20. Barriers to colorectal cancer screening among women in rural central Pennsylvania: Primary care physicians’ perspective

    PubMed Central

    Rosenwasser, Lara A.; McCall-Hosenfeld, Jennifer S.; Weisman, Carol S.; Hillemeier, Marianne M.; Perry, Amanda N.; Chuang, Cynthia H.

    2014-01-01

    Introduction Colorectal cancer (CRC) is the third leading cause of death among U.S. women. Rural populations have lower rates of CRC screening than their urban counterparts, and rural women have lower screening rates compared with rural men. The purpose of this qualitative study was to identify (1) primary care physicians’ (PCP) beliefs regarding CRC screening in rural communities, (2) factors that may cause gender disparities in CRC screening in rural areas, and (3) solutions to overcome those barriers. Methods Semi-structured interviews were conducted with 17 PCPs practicing in rural central Pennsylvania. PCPs were asked about their CRC screening practices for women, availability of CRC screening services, reminder systems for CRC screening, and barriers to screening specific to their rural communities and to gender. Thematic analysis was used to identify major themes. Results All 17 PCPs endorsed the importance of CRC screening, but believed that there are barriers to CRC screening specific to women and to rural location. All PCPs identified colonoscopy as their screening method of choice, and generally reported that access to colonoscopy services in their rural areas was not a significant barrier. Barriers to CRC screening for women in rural communities were related to: 1) PCPs’ CRC screening practices (e.g., not using alternative screening modalities when colonoscopy is not possible), 2) gender-specific barriers to CRC screening (e.g., patients’ belief that CRC mostly affects men, embarrassment of knowing people at the endoscopy center, prioritization of family issues over personal health), 3) patient-related barriers (e.g., low educational attainment, low health literacy, poverty, under- or uninsured), 4) community-related barriers (e.g., inadequate public education about CRC, “rural culture” that does not emphasize importance of preventive health services), and 5) physician practice-related barriers (e.g., lack of effective reminder systems, lack of time, busy practices). Physicians overwhelmingly identified patient education as necessary for improving CRC screening in their rural communities, but believed that education would have to come from a source outside the rural primary care office due to lack of resources, personnel, and time. Conclusions Overall, the PCPs in this study were motivated to identify ways to improve their ability to engage more eligible patients in CRC screening. These findings suggest several interventions to potentially improve CRC screening for women in rural areas, including encouraging use of other effective CRC screening modalities (i.e., FOBT) when colonoscopy is not possible; systems-based reminders that leverage electronic resources and are not visit dependent; and public health education campaigns aimed specifically at women in rural communities. PMID:24099635

  1. Virtually assisted optical colonoscopy

    NASA Astrophysics Data System (ADS)

    Marino, Joseph; Qiu, Feng; Kaufman, Arie

    2008-03-01

    We present a set of tools used to enhance the optical colonoscopy procedure in a novel manner with the aim of improving both the accuracy and efficiency of this procedure. In order to better present the colon information to the gastroenterologist performing a conventional (optical) colonoscopy, we undistort the radial distortion of the fisheye view of the colonoscope. The radial distortion is modeled with a function that converts the fisheye view to the perspective view, where the shape and size of polyps can be more readily observed. The conversion, accelerated on the graphics processing unit and running in real-time, calculates the corresponding position in the fisheye view of each pixel on the perspective image. We also merge our previous work in computer-aided polyp detection for virtual colonoscopy into the optical colonoscopy environment. The physical colonoscope path in the optical colonoscopy is approximated with the hugging corner shortest path, which is correlated with the centerline in the virtual colonoscopy. With the estimated distance that the colonoscope has been inserted, we are able to provide the gastroenterologist with visual cues along the observation path as to the location of possible polyps found by the detection process. In order to present the information to the gastroenterologist in a non-intrusive manner, we have developed a friendly user interface to enhance the optical colonoscopy without being cumbersome, distracting, or resulting in a more lackadaisical inspection by the gastroenterologist.

  2. Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics

    PubMed Central

    RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.

    2015-01-01

    BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665

  3. Do patients undergo prostate examination while having a colonoscopy?

    PubMed

    Hammett, Tess; Hookey, Lawrence C; Kawakami, Jun

    2009-01-01

    To determine the rate at which physicians report performing a digital rectal examination and comment on the prostate gland before performing colonoscopy in men 50 to 70 years of age. A retrospective chart review of all men 50 to 70 years of age who had a colonoscopy in Kingston, Ontario, in 2005 was completed. It was noted whether each physician described performing a digital rectal examination before the colonoscopy, and if so, whether he or she commented on the prostate. In 2005, 846 eligible colonoscopies were performed by 17 physicians in Kingston, Ontario. In 29.2% of cases, the physician made no comment about having performed a digital rectal examination; in 55.8% of cases, the physician commented on having completed a digital rectal examination but said nothing about the prostate; and in 15.0% of cases, the physician made a comment regarding the prostate. No physician consistently commented on the prostate for all patients, and in no circumstances was direct referral to another physician or follow-up suggested. A colonoscopy presents an ideal opportunity for physicians to use a digital rectal examination to assess for prostate cancer. Physicians performing colonoscopies in men 50 to 70 years of age should pay special attention to the prostate while performing a digital rectal examination before colonoscopy. This novel concept may help maximize resources for cancer screening and could potentially increase the detection rate of clinically palpable prostate cancer.

  4. [Analysis of community colorectal cancer screening in 50-74 years old people in Guangzhou, 2015-2016].

    PubMed

    Li, Y; Liu, H Z; Liang, Y R; Lin, G Z; Li, K; Dong, H; Xu, H; Wang, M

    2018-01-10

    Objective: To analyze the effect of colorectal cancer screening in the general population in Guangzhou, and provide evidence for the for development of colorectal cancer screening policy and strategy. Methods: The data of colorectal cancer screening in Guangzhou during 2015- 2016 were collected. The participation, the positive rate of fecal occult blood test, the detection rate of colonoscopy and screening effect of colonoscopy were evaluated. Results: A total of 220 834 residents aged 50-74 years received the screening, and the positive rate of the screening was 16.77% (37 040 cases). Colonoscopy was performed for 7 821 cases (21.12%). Colorectal lesions were found in 4 126 cases (52.76%), of which 614 (7.85%) and 73 (0.93%) and 230 (2.94%) were identified as advanced adenoma, severe dysplasia lesions and colorectal cancers, respectively. The detection rates of all colorectal lesions were higher in men than in women (all P <0.01). The diagnostic rate of early lesion was 87.24%, and 99 early cancer cases were found, accounting for 46.26% of the total cases. The overall screening detection rate of colorectal cancer was 104.15/100 000, higher than the incidence rate (81.18/100 000) in colorectal cancer surveillance ( P <0.001), but age group <70 years had higher detection rate, age group ≥70 years had higher incidence rate. Conclusions: The colorectal cancer screening strategy in Guangzhou is effective in the detection of the population at high risk, increase the detection rate of colorectal lesions, early diagnosis rate of precancerous lesions and diagnosis rate of early colorectal cancer. The benefit in those aged ≤69 years was more obvious than that in those aged 70-74 years. It is necessary to improve the compliancy of colorectal cancer screening in population at high risk.

  5. The effectiveness of simethicone in improving visibility during colonoscopy when given with a sodium phosphate solution: a double-bind randomized study.

    PubMed

    Sudduth, R H; DeAngelis, S; Sherman, K E; McNally, P R

    1995-11-01

    Oral sodium phosphate solution is better tolerated than polyethylene glycol when used for colonoscopy preparation, but visibility of the lumen can be impaired because of the presence of bubbles. We studied 86 patients receiving either simethicone (n = 42) or placebo (n = 44) in addition to oral sodium phosphate to determine if simethicone improved visibility during colonoscopy. Colonoscopy was performed by a single blinded investigator. Five areas of the colon (rectosigmoid, descending, transverse, ascending, and cecum) were assessed for the presence of bubbles on withdrawal of the endoscope. Bubbles were scored as follows: 0, minimal or none; 1, covering half the lumen; 2, covering the entire circumference; 3 filling the entire lumen. Thirteen patients in the placebo group and only one in the simethicone had significant bubbles ( > or = 1). Additionally, the mean bubble scores were greater in the placebo group in each region of the colon (p < or = 0.05 in rectosigmoid and ascending colon). This study indicates that taking simethicone with an oral sodium phosphate preparation can improve colonic visibility by diminishing the presence of bubbles. Better visualization could improve detection of mucosal pathologic lesions.

  6. Endoscopic innovations to increase the adenoma detection rate during colonoscopy

    PubMed Central

    Dik, Vincent K; Moons, Leon MG; Siersema, Peter D

    2014-01-01

    Up to a quarter of polyps and adenomas are missed during colonoscopy due to poor visualization behind folds and the inner curves of flexures, and the presence of flat lesions that are difficult to detect. These numbers may however be conservative because they mainly come from back-to-back studies performed with standard colonoscopes, which are unable to visualize the entire mucosal surface. In the past several years, new endoscopic techniques have been introduced to improve the detection of polyps and adenomas. The introduction of high definition colonoscopes and visual image enhancement technologies have been suggested to lead to better recognition of flat and small lesions, but the absolute increase in diagnostic yield seems limited. Cap assisted colonoscopy and water-exchange colonoscopy are methods to facilitate cecal intubation and increase patients comfort, but show only a marginal or no benefit on polyp and adenoma detection. Retroflexion is routinely used in the rectum for the inspection of the dentate line, but withdrawal in retroflexion in the colon is in general not recommended due to the risk of perforation. In contrast, colonoscopy with the Third-Eye Retroscope® may result in considerable lower miss rates compared to standard colonoscopy, but this technique is not practical in case of polypectomy and is more time consuming. The recently introduced Full Spectrum Endoscopy™ colonoscopes maintains the technical capabilities of standard colonoscopes and provides a much wider view of 330 degrees compared to the 170 degrees with standard colonoscopes. Remarkable lower adenoma miss rates with this new technique were recently demonstrated in the first randomized study. Nonetheless, more studies are required to determine the exact additional diagnostic yield in clinical practice. Optimizing the efficacy of colorectal cancer screening and surveillance requires high definition colonoscopes with improved virtual chromoendoscopy technology that visualize the whole colon mucosa while maintaining optimal washing, suction and therapeutic capabilities, and keeping the procedural time as low and patient discomfort as optimal as possible. PMID:24605019

  7. Pneumothorax, Pneumomediastinum, Pneumoperitoneum, Pneumoretroperitoneum and Subcutaneous Emphysema Following Diagnostic Colonoscopy

    PubMed Central

    Marwan, K; Farmer, KC; Varley, C; Chapple, KS

    2007-01-01

    Colonic perforation is an unusual complication of colonoscopy. We present a case of pneumothorax, pneumomediastinum, pneumoperitoneum and extensive subcutaneous emphysema resulting from a diagnostic colonoscopy. To our knowledge, only two such cases have been described previously. PMID:17688713

  8. Optimism and barriers to colonoscopy in low-income Latinos at average risk for colorectal cancer.

    PubMed

    Efuni, Elizaveta; DuHamel, Katherine N; Winkel, Gary; Starr, Tatiana; Jandorf, Lina

    2015-09-01

    Colorectal cancer (CRC) screening continues to be underused, particularly by Latinos. CRC and colonoscopy fear, worry, and fatalism have been identified as screening barriers in Latinos. The study purpose was to examine the relationship of optimism, fatalism, worry, and fear in the context of Latinos referred for CRC screening. Our sample included 251 Latinos between the ages of 50 and 83 years who had no personal or immediate family history of CRC, no personal history of gastrointestinal disorder, no colonoscopy in the past 5 years, and received a referral for a colonoscopy. Face-to-face interviews were performed, and data were analyzed using regression models. Greater optimism (β = -1.72, p < 0.000), lower fatalism (β = 0.29, p < 0.01), and absence of family history of cancer (β = 1, p < 0.01) were associated with decreased worry about the colonoscopy. Being female (β = 0.85, p < 0.05) and born in the USA (β = 1.1, p < 0.01) were associated with greater worry about colonoscopy and the possibility of having CRC. Family history of cancer (β = 2.6, p < 0.01), female gender (β = 2.9, p < 0.000), not following the doctor's advice (β = 2.7, p < 0.01), and putting off medical problems (β = 1.9, p < 0.05) were associated with greater fear. In the multiple regression model, lower optimism (β = -0.09, p < 0.05), higher fatalism (β = 0.28, p < 0.01), and female gender (β = 0.9, p < 0.05) were associated with greater worry. Interventions that address fatalism and promote optimistic beliefs may reduce worry among Latinos referred for colonoscopy. Interventions that alleviate colonoscopy fear because of family history of cancer particularly among Latino women may help improve distress about CRC screening. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm.

    PubMed

    Woo, Jaehong; Choi, Jae Hyuk; Seo, Jong Tae; Kim, Tae Il; Yi, Byung Ju

    2017-01-01

    Colonoscopy is one of the most effective diagnostic and therapeutic tools for colorectal diseases. We aim to propose a master-slave robotic colonoscopy that is controllable in remote site using conventional colonoscopy. The master and slave robot were developed to use conventional flexible colonoscopy. The robotic colonoscopic procedure was performed using a colonoscope training model by one expert endoscopist and two unexperienced engineers. To provide the haptic sensation, the insertion force and the rotating torque were measured and sent to the master robot. A slave robot was developed to hold the colonoscopy and its knob, and perform insertion, rotation, and two tilting motions of colonoscope. A master robot was designed to teach motions of the slave robot. These measured force and torque were scaled down by one tenth to provide the operator with some reflection force and torque at the haptic device. The haptic sensation and feedback system was successful and helpful to feel the constrained force or torque in colon. The insertion time using robotic system decreased with repeated procedures. This work proposed a robotic approach for colonoscopy using haptic feedback algorithm, and this robotic device would effectively perform colonoscopy with reduced burden and comparable safety for patients in remote site.

  10. Image Retrieval Method for Multiscale Objects from Optical Colonoscopy Images

    PubMed Central

    Sakanashi, Hidenori; Takahashi, Eiichi; Murakawa, Masahiro; Aoki, Hiroshi; Takeuchi, Ken; Suzuki, Yasuo

    2017-01-01

    Optical colonoscopy is the most common approach to diagnosing bowel diseases through direct colon and rectum inspections. Periodic optical colonoscopy examinations are particularly important for detecting cancers at early stages while still treatable. However, diagnostic accuracy is highly dependent on both the experience and knowledge of the medical doctor. Moreover, it is extremely difficult, even for specialist doctors, to detect the early stages of cancer when obscured by inflammations of the colonic mucosa due to intractable inflammatory bowel diseases, such as ulcerative colitis. Thus, to assist the UC diagnosis, it is necessary to develop a new technology that can retrieve similar cases of diagnostic target image from cases in the past that stored the diagnosed images with various symptoms of colonic mucosa. In order to assist diagnoses with optical colonoscopy, this paper proposes a retrieval method for colonoscopy images that can cope with multiscale objects. The proposed method can retrieve similar colonoscopy images despite varying visible sizes of the target objects. Through three experiments conducted with real clinical colonoscopy images, we demonstrate that the method is able to retrieve objects of any visible size and any location at a high level of accuracy. PMID:28255295

  11. Image Retrieval Method for Multiscale Objects from Optical Colonoscopy Images.

    PubMed

    Nosato, Hirokazu; Sakanashi, Hidenori; Takahashi, Eiichi; Murakawa, Masahiro; Aoki, Hiroshi; Takeuchi, Ken; Suzuki, Yasuo

    2017-01-01

    Optical colonoscopy is the most common approach to diagnosing bowel diseases through direct colon and rectum inspections. Periodic optical colonoscopy examinations are particularly important for detecting cancers at early stages while still treatable. However, diagnostic accuracy is highly dependent on both the experience and knowledge of the medical doctor. Moreover, it is extremely difficult, even for specialist doctors, to detect the early stages of cancer when obscured by inflammations of the colonic mucosa due to intractable inflammatory bowel diseases, such as ulcerative colitis. Thus, to assist the UC diagnosis, it is necessary to develop a new technology that can retrieve similar cases of diagnostic target image from cases in the past that stored the diagnosed images with various symptoms of colonic mucosa. In order to assist diagnoses with optical colonoscopy, this paper proposes a retrieval method for colonoscopy images that can cope with multiscale objects. The proposed method can retrieve similar colonoscopy images despite varying visible sizes of the target objects. Through three experiments conducted with real clinical colonoscopy images, we demonstrate that the method is able to retrieve objects of any visible size and any location at a high level of accuracy.

  12. A randomized, blinded, prospective trial to compare the safety and efficacy of three bowel-cleansing solutions for colonoscopy (HSG-01*).

    PubMed

    Ell, C; Fischbach, W; Keller, R; Dehe, M; Mayer, G; Schneider, B; Albrecht, U; Schuette, W

    2003-04-01

    There are conflicting data regarding the optimal bowel preparation for colonoscopy. This study was carried out to compare the efficacy, safety, and tolerability of three widely used bowel lavage solutions: the standard polyethylene glycol-electrolyte solution based on the GoLytely formulation (PEG-EL1; Klean-Prep); a sulphate-free PEG-EL solution based on the NuLytely formulation (PEG-EL2, Endofalk); and a sodium phosphate preparation (NaP, Fleet Phospho-Soda). A total of 185 consecutive patients scheduled for elective colonoscopy were prospectively randomly assigned to undergo pre-colonoscopic bowel cleansing with either 4 l of PEG-EL1 (n=64), 3 l of PEG-EL2 (n=59), or 90 ml of NaP (n=62). The quality of preparatory colonic cleansing for each segment from the rectum to the ascending colon was scored on a five-level rating scale (1, very good to 5, very poor) by endoscopists who were blinded with regard to the type of preparation used. The primary outcome measure for the comparison of treatments was the "worst" score in any of the rated bowel segments. Safety and tolerability were evaluated by means of a symptom questionnaire completed by each patient immediately before the procedure. Of the 185 patients who were randomly assigned to one of the three treatments, 175 underwent colonoscopy and 173 were evaluable with regard to efficacy - 59, 54, and 60 patients treated with PEG-EL1, PEG-EL2, and NaP, respectively. The treatment groups were comparable with regard to the baseline characteristics. PEG-EL1 was statistically significantly superior to the other treatments in relation to the "worst cleansing" score ( P

  13. Colonoscopy uptake for high-risk individuals with a family history of colorectal neoplasia: A multicenter, randomized trial of tailored counseling versus standard information.

    PubMed

    Ingrand, Isabelle; Defossez, Gautier; Richer, Jean-Pierre; Tougeron, David; Palierne, Nicolas; Letard, Jean-Christophe; Beauchant, Michel; Ingrand, Pierre

    2016-08-01

    Colonoscopic screening is recommended for first-degree relatives of patients diagnosed with colorectal cancer (CRC) or colorectal adenomatous polyps (CAP) before the age of 60 years. This has the potential to reduce CRC-related morbidity and mortality, but uptake is currently inadequate. The aim of the study was to compare the effectiveness of standard information versus a nurse-led tailored intervention designed to promote uptake of colonoscopy screening by siblings of CRC or CAP patients. A randomized controlled trial was conducted. Digestive surgeons and gastroenterologists recruited index patients who developed CRC or CAP before the age of 60 years. All index patients received standard screening information for their siblings, in keeping with current guidelines. Centrally computerized randomization of index patients resulted in allocating all their siblings to the same group, intervention or control. The tailored intervention targeted the index patient first, to help them convey information to their siblings. The nurse then provided the siblings with tailored information based on their answers to a self-questionnaire which explored health behaviors, derived from psychosocial models of prevention. Then the siblings were given a personalized information leaflet to hand to their regular physician. The primary endpoint was the rate of documented colonoscopy performed in siblings within 1 year after diagnosis of the index patient. The intent-to-treat analysis included siblings who refused to participate in the study. Statistical analysis was adjusted for intrafamilial correlation. A total of 304 siblings of 125 index patients were included: 160 in the intervention group and 144 in the control group. The rate of colonoscopy uptake among siblings was 56.3% in the intervention group and 35.4% in the control group (P = 0.0027). The respective rates after exclusion of refusals were 69.2% and 37.0% (P < 0.0001). More lesions were detected in the intervention group (1 invasive cancer and 11 advanced adenomas vs 5 advanced adenomas; P = 0.022). This study demonstrates the effectiveness of a nurse-led tailored intervention designed to promote colonoscopy screening uptake by siblings of patients diagnosed with CRC or CAP before age 60 years. Such tailored interventions that also involve physicians should help to reduce CRC-related mortality.

  14. [Colonoscopy for early detection and prevention of colorectal cancer].

    PubMed

    Niv, Yaron

    2010-08-01

    Colonoscopy has a limited success in the prevention of colorectal cancer of the right colon. Thus, there is place for improvement. The potential reasons for colonoscopy failure are the different biology of polyps on the right side of the colon or procedure quality. Preparation, withdrawal time, detection of all polyps and their removal using the best technique will overcome this problem. Furthermore, the implementation of a computerized database and report that includes quality assurance fields, will improve colonoscopy success rates.

  15. Reiki as a pain management adjunct in screening colonoscopy.

    PubMed

    Bourque, Alda L; Sullivan, Mary E; Winter, Michael R

    2012-09-01

    The purpose of this study was to determine whether the use of Reiki decreases the amount of meperidine administered to patients undergoing screening colonoscopy. The literature review reveals limited studies to show whether Reiki has been able to decrease the amount of opioid the patient receives during screening colonoscopy. A chart review of 300 patients was conducted to obtain baseline average doses of meperidine patients received as the control. Following the chart review, 30 patients were recruited to the Reiki study. Twenty-five of the study arm patients received Reiki in conjunction with meperidine. Five randomly chosen study arm patients received placebo Reiki in conjunction with meperidine in an attempt to blind the clinicians to the treatment received by the patients. Results showed that there were no significant differences in meperidine administration between the patients in the chart review group (control) and the Reiki group. The study revealed that 16% who received Reiki, together with intravenous administration of conscious sedation, received less than 50 mg of meperidine. All the patients in the chart review group received more than 50 mg of meperidine. Results from this pilot study suggest that there may be a decrease in meperidine needed during screening colonoscopy when patients receive Reiki treatments before the procedure. A larger study powered to detect smaller medication differences is the next step in more accurately determining the effect of Reiki on pain management.

  16. Causes Of Lower Gastrointestinal Bleeding On Colonoscopy.

    PubMed

    Jehangiri, Attique-Ur-Rehman; Gul, Rahid; Hadayat, Rania; Khan, Adil Naseer; Zabiullah; Khursheed, Liaqat

    2017-01-01

    Bleeding from anus is usually referred as rectal bleeding but actually rectal bleeding is defined as bleeding from lower colon or rectum, which means bleeding from a place distal to ligament of Treitz. This study was conducted to determine the frequency of different causes of rectal bleeding in patients at Ayub Teaching Hospital, Abbottabad. One hundred and seventy-five patients with evidence of rectal bleed, without gender discrimination were selected by non-probability convenient sampling from the out-patient department and general medical wards. Patients with suspected upper GI source of bleeding; acute infectious bloody diarrhoea and any coagulopathy were excluded from the study. All patients were subjected to fibre optic colonoscopy after preparation of the gut and findings were recorded. Where necessary, biopsy samples were also taken. Diagnosis was based on colonoscopic findings. A total of 175 patients (92 males and 83 females) with mean age 35.81±9.18 years were part of the study. Colonoscopy showed abnormal findings in 150 (85.7%) patients. The commonest diagnosis was haemorrhoids, which was found in 39 (22.3%) patients. It was followed by inflammatory bowel disease (IBD) in 30 (17.1%) patients, solitary rectal ulcer in 13 (7.4%) patients and polyps in 25 (14.3%) patients. Other less frequent findings were non-specific inflammation and fungating growths in rectum. Haemorrhoids was the leading cause of bleeding per rectum in this study, followed by evidence of IBD while infrequent findings of polyps and diverticuli indicate that these are uncommon in this region.

  17. Progressive learning in endoscopy simulation training improves clinical performance: a blinded randomized trial.

    PubMed

    Grover, Samir C; Scaffidi, Michael A; Khan, Rishad; Garg, Ankit; Al-Mazroui, Ahmed; Alomani, Tareq; Yu, Jeffrey J; Plener, Ian S; Al-Awamy, Mohamed; Yong, Elaine L; Cino, Maria; Ravindran, Nikila C; Zasowski, Mark; Grantcharov, Teodor P; Walsh, Catharine M

    2017-11-01

    A structured comprehensive curriculum (SCC) that uses simulation-based training (SBT) can improve clinical colonoscopy performance. This curriculum may be enhanced through the application of progressive learning, a training strategy centered on incrementally challenging learners. We aimed to determine whether a progressive learning-based curriculum (PLC) would lead to superior clinical performance compared with an SCC. This was a single-blinded randomized controlled trial conducted at a single academic center. Thirty-seven novice endoscopists were recruited and randomized to either a PLC (n = 18) or to an SCC (n = 19). The PLC comprised 6 hours of SBT, which progressed in complexity and difficulty. The SCC included 6 hours of SBT, with cases of random order of difficulty. Both groups received expert feedback and 4 hours of didactic teaching. Participants were assessed at baseline, immediately after training, and 4 to 6 weeks after training. The primary outcome was participants' performance during their first 2 clinical colonoscopies, as assessed by using the Joint Advisory Group Direct Observation of Procedural Skills assessment tool (JAG DOPS). Secondary outcomes were differences in endoscopic knowledge, technical and communication skills, and global performance in the simulated setting. The PLC group outperformed the SCC group during first and second clinical colonoscopies, measured by JAG DOPS (P < .001). Additionally, the PLC group had superior technical and communication skills and global performance in the simulated setting (P < .05). There were no differences between groups in endoscopic knowledge (P > .05). Our findings demonstrate the superiority of a PLC for endoscopic simulation, compared with an SCC. Challenging trainees progressively is a simple, theory-based approach to simulation whereby the performance of clinical colonoscopies can be improved. (Clinical trial registration number: NCT02000180.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  18. Early Adoption of a Multi-target Stool DNA Test for Colorectal Cancer Screening

    PubMed Central

    Finney Rutten, Lila J.; Jacobson, Robert M.; Wilson, Patrick M.; Jacobson, Debra J.; Fan, Chun; Kisiel, John B.; Sweetser, Seth R.; Tulledge-Scheitel, Sidna M.; St. Sauver, Jennifer L.

    2017-01-01

    Objective To characterize early adoption of a novelmulti-target stool deoxyribonucleic acid (MTsDNA) screening test for colorectal cancer (CRC) and test the hypothesis that adoption differs by demographic characteristics, prior CRC screening behavior, and proceeds predictably over time. Patients and Methods We used the Rochester Epidemiology Project infrastructure to assess MTsDNA screening test use among adults aged 50–75 years, and identified 27,147 individuals eligible/due for screening colonoscopy from November 1, 2014 through November 30, 2015, and living in Olmsted County, Minnesota in2014. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of MTsDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior screening behavior. Results Overall, 2,193 (8.1%) and 974 (3.6%) of individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior screening were significantly and independently associated with MT-sDNA screening use compared to colonoscopy use after adjustment for all other variables. Rates of adoption of MTsDNA screening increased over time and were highest among those aged 50–54 years, females, whites, and had a prior history of screening. MT-sDNA screening use varied predictably by insurance coverage. Rates of colonoscopy decreased over time, while overall CRC screening rates remained steady. Conclusion Our results are generally consistent with predictions derived from prior research and Diffusion of Innovation framework, pointing to increasing use of the new screening test over time, and early adoption by younger patients, females, whites and those with prior CRC screening. PMID:28473037

  19. Risk of Advanced Neoplasia in First-Degree Relatives with Colorectal Cancer: A Large Multicenter Cross-Sectional Study

    PubMed Central

    Quintero, Enrique; Gargallo, Carla; Lanas, Angel; Bujanda, Luis; Gimeno-García, Antonio Z.; Hernández-Guerra, Manuel; Nicolás-Pérez, David; Alonso-Abreu, Inmaculada; Morillas, Juan Diego; Balaguer, Francesc; Muriel, Alfonso

    2016-01-01

    Background First-degree relatives (FDR) of patients with colorectal cancer have a higher risk of developing colorectal cancer than the general population. For this reason, screening guidelines recommend colonoscopy every 5 or 10 y, starting at the age of 40, depending on whether colorectal cancer in the index-case is diagnosed at <60 or ≥60 y, respectively. However, studies on the risk of neoplastic lesions are inconclusive. The aim of this study was to determine the risk of advanced neoplasia (three or more non-advanced adenomas, advanced adenoma, or invasive cancer) in FDR of patients with colorectal cancer compared to average-risk individuals (i.e., asymptomatic adults 50 to 69 y of age with no family history of colorectal cancer). Methods and Findings This cross-sectional analysis includes data from 8,498 individuals undergoing their first lifetime screening colonoscopy between 2006 and 2012 at six Spanish tertiary hospitals. Of these individuals, 3,015 were defined as asymptomatic FDR of patients with colorectal cancer (“familial-risk group”) and 3,038 as asymptomatic with average-risk for colorectal cancer (“average-risk group”). The familial-risk group was stratified as one FDR, with one family member diagnosed with colorectal cancer at ≥60 y (n = 1,884) or at <60 y (n = 831), and as two FDR, with two family members diagnosed with colorectal cancer at any age (n = 300). Multiple logistic regression analysis was used for between-group comparisons after adjusting for potential confounders (age, gender, and center). Compared with the average-risk group, advanced neoplasia was significantly more prevalent in individuals having two FDR with colorectal cancer (odds ratio [OR] 1.90; 95% confidence interval [CI] 1.36–2.66, p < 0.001), but not in those having one FDR with colorectal cancer diagnosed at ≥60 y (OR 1.03; 95% CI 0.83–1.27, p = 0.77) and <60 y (OR 1.19; 95% CI 0.90–1.58, p = 0.20). After the age of 50 y, men developed advanced neoplasia over two times more frequently than women and advanced neoplasia appeared at least ten y earlier. Fewer colonoscopies by 2-fold were required to detect one advanced neoplasia in men than in women. Major limitations of this study were first that although average-risk individuals were consecutively included in a randomized control trial, this was not the case for all individuals in the familial-risk cohort; and second, the difference in age between the average-risk and familial-risk cohorts. Conclusions Individuals having two FDR with colorectal cancer showed an increased risk of advanced neoplasia compared to those with average-risk for colorectal cancer. Men had over 2-fold higher risk of advanced neoplasia than women, independent of family history. These data suggest that screening colonoscopy guidelines should be revised in the familial-risk population. PMID:27138769

  20. Prevalence of advanced adenomas in small and diminutive colon polyps using direct measurement of size.

    PubMed

    Tsai, Franklin C; Strum, Williamson B

    2011-08-01

    Most studies reporting polyp size use visual estimates. Determining the prevalence of advanced histology based on direct measurement of polyp size may help guide the management of polyps found at optical colonoscopy (OC) and CT colonography (CTC). We designed a large, prospective study to assess the prevalence of advanced adenomas based on direct measurement of polyp size by a certified pathologists' assistant as reported in the pathology report. Patients between 40 and 89 years of age who presented for screening colonoscopy were included in our study. Advanced adenomas were defined as ≥10 mm or ≥25% villous features, high grade dysplasia or cancer. Polyps were divided by size into three groups: diminutive (≤5 mm), small (6-9 mm) and large (≥10 mm). If more than one adenoma was present, the most advanced was used for analysis. We evaluated 6,905 consecutive patients referred for colonoscopy between January 2005 and December 2006. Of the 4,967 who met the inclusion criteria, the mean age was 58.8 and consisted of 59% women. Overall, 930 (18.7%) had an adenoma; 248 (5%) were advanced adenomas including 8 (0.16%) cancers. Of 89 polyps≥10 mm, 76 (85%) had advanced histology; of 247 polyps 6-9 mm, 67 (27%) were advanced; of 1,025 polyps ≤5 mm, 105 (10%) were advanced. Thus, 172 of 248 (69%) patients with advanced adenomas had small or diminutive adenomas. Our data indicate the majority (69%) of advanced adenomas are <10 mm. Even among polyps≤5 mm, there was an appreciable prevalence of advanced adenomas (10%). These findings may help guide the management of sub-centimeter colon polyps found by OC or CTC.

  1. Is water exchange superior to water immersion for colonoscopy? A systematic review and meta-analysis.

    PubMed

    Chen, Zhihao; Li, Zhengqi; Yu, Xinying; Wang, Guiqi

    2018-06-05

    Recently, water exchange (WE) instead of water immersion (WI) for colonoscopy has been proposed to decrease pain and improve adenoma detection rate (ADR). This systematic review and meta-analysis is conducted to assess whether WE is superior to WI based on the published randomized controlled trials (RCTs). We searched studies from PubMed, Cochrane Central Register of Controlled Trials, EMBASE, and MEDLINE. Only RCTs were eligible for our study. The pooled risk ratios (RRs), pooled mean difference (MD), and pooled 95% confidence intervals (CIs) were calculated by using the fixed-effects model or random-effects model based on heterogeneity. Five RCTs consisting of 2229 colonoscopies were included in this study. WE was associated with a significantly higher ADR than WI (RR = 1.18; CI = 1.05-1.32; P = 0.004), especially in right colon (RR = 1.31; CI = 1.07-1.61; P = 0.01). Compared with WI, WE was confirmed with lower pain score, higher Boston Bowel Preparation Scale score, but more infused water during insertion. There was no statistical difference between WE and WI in cecal intubation rate and the number of patients who had willingness to repeat the examination. Furthermore, both total procedure time and cecal intubation time in WE were significantly longer than that in WI (MD = 2.66; CI = 1.42-3.90; P < 0.0001; vs MD = 4.58; CI = 4.01-5.15; P < 0.0001). This meta-analysis supports the hypothesis that WE is superior to WI in improving ADR, attenuating insertion pain and providing better bowel cleansing, but inferior in time and consumption of infused water consumption during insertion.

  2. Tissue resonance interaction accurately detects colon lesions: A double-blind pilot study.

    PubMed

    Dore, Maria P; Tufano, Marcello O; Pes, Giovanni M; Cuccu, Marianna; Farina, Valentina; Manca, Alessandra; Graham, David Y

    2015-07-07

    To investigated the performance of the tissue resonance interaction method (TRIM) for the non-invasive detection of colon lesions. We performed a prospective single-center blinded pilot study of consecutive adults undergoing colonoscopy at the University Hospital in Sassari, Italy. Before patients underwent colonoscopy, they were examined by the TRIMprobe which detects differences in electromagnetic properties between pathological and normal tissues. All patients had completed the polyethylene glycol-containing bowel prep for the colonoscopy procedure before being screened. During the procedure the subjects remained fully dressed. A hand-held probe was moved over the abdomen and variations in electromagnetic signals were recorded for 3 spectral lines (462-465 MHz, 930 MHz, and 1395 MHz). A single investigator, blind to any clinical information, performed the test using the TRIMprob system. Abnormal signals were identified and recorded as malignant or benign (adenoma or hyperplastic polyps). Findings were compared with those from colonoscopy with histologic confirmation. Statistical analysis was performed by χ(2) test. A total of 305 consecutive patients fulfilling the inclusion criteria were enrolled over a period of 12 months. The most frequent indication for colonoscopy was abdominal pain (33%). The TRIMprob was well accepted by all patients; none spontaneously complained about the procedure, and no adverse effects were observed. TRIM proved inaccurate for polyp detection in patients with inflammatory bowel disease (IBD) and they were excluded leaving 281 subjects (mean age 59 ± 13 years; 107 males). The TRIM detected and accurately characterized all 12 adenocarcinomas and 135/137 polyps (98.5%) including 64 adenomatous (100%) found. The method identified cancers and polyps with 98.7% sensitivity, 96.2% specificity, and 97.5% diagnostic accuracy, compared to colonoscopy and histology analyses. The positive predictive value was 96.7% and the negative predictive value 98.4%. Among the 281 non-IBD subjects, there were 7 cases with discordant results (2.5%) between TRIMprob and the reference standard including 5 false positive results (1.8%) and 2 false negative (0.7%) results. The main limitation of the TRIMprob system is the need for trained operators. The study confirmed that TRIM provides rapid, accurate, convenient and noninvasive means to identify individuals most likely to benefit from colonoscopy.

  3. Tissue resonance interaction accurately detects colon lesions: A double-blind pilot study

    PubMed Central

    Dore, Maria P; Tufano, Marcello O; Pes, Giovanni M; Cuccu, Marianna; Farina, Valentina; Manca, Alessandra; Graham, David Y

    2015-01-01

    AIM: To investigated the performance of the tissue resonance interaction method (TRIM) for the non-invasive detection of colon lesions. METHODS: We performed a prospective single-center blinded pilot study of consecutive adults undergoing colonoscopy at the University Hospital in Sassari, Italy. Before patients underwent colonoscopy, they were examined by the TRIMprobe which detects differences in electromagnetic properties between pathological and normal tissues. All patients had completed the polyethylene glycol-containing bowel prep for the colonoscopy procedure before being screened. During the procedure the subjects remained fully dressed. A hand-held probe was moved over the abdomen and variations in electromagnetic signals were recorded for 3 spectral lines (462-465 MHz, 930 MHz, and 1395 MHz). A single investigator, blind to any clinical information, performed the test using the TRIMprob system. Abnormal signals were identified and recorded as malignant or benign (adenoma or hyperplastic polyps). Findings were compared with those from colonoscopy with histologic confirmation. Statistical analysis was performed by χ2 test. RESULTS: A total of 305 consecutive patients fulfilling the inclusion criteria were enrolled over a period of 12 months. The most frequent indication for colonoscopy was abdominal pain (33%). The TRIMprob was well accepted by all patients; none spontaneously complained about the procedure, and no adverse effects were observed. TRIM proved inaccurate for polyp detection in patients with inflammatory bowel disease (IBD) and they were excluded leaving 281 subjects (mean age 59 ± 13 years; 107 males). The TRIM detected and accurately characterized all 12 adenocarcinomas and 135/137 polyps (98.5%) including 64 adenomatous (100%) found. The method identified cancers and polyps with 98.7% sensitivity, 96.2% specificity, and 97.5% diagnostic accuracy, compared to colonoscopy and histology analyses. The positive predictive value was 96.7% and the negative predictive value 98.4%. Among the 281 non-IBD subjects, there were 7 cases with discordant results (2.5%) between TRIMprob and the reference standard including 5 false positive results (1.8%) and 2 false negative (0.7%) results. The main limitation of the TRIMprob system is the need for trained operators. CONCLUSION: The study confirmed that TRIM provides rapid, accurate, convenient and noninvasive means to identify individuals most likely to benefit from colonoscopy. PMID:26167085

  4. Indications for colonoscopy in patients with systemic lupus erythematosus.

    PubMed

    Iwamuro, Masaya; Okada, Hiroyuki; Kato, Jun; Tanaka, Takehiro; Sada, Ken-Ei; Makino, Hirofumi; Yamamoto, Kazuhide

    2013-01-01

    Systemic lupus erythematosus is a systemic autoimmune disorder that sometimes involves the gastrointestinal tract. The aim of this study is to describe the clinical characteristics of patients with systemic lupus erythematosus with colorectal involvement, and to provide criteria for colonoscopy. Among 288 patients with systemic lupus erythematosus, 29 patients underwent colonoscopy. The clinical backgrounds were comparatively analyzed between the patients with colorectal involvements (n = 11, group A) and the patients without colorectal involvements (n = 18, group B). Endoscopic features were also evaluated in group A patients. The Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) of the group A patients was higher than that of the group B patients. Abdominal pain (n = 6) and diarrhea (n = 5) were significantly correlated with the presence of colorectal involvements, and other manifestations in group A patients included visible blood in stools (n = 5) and fever (n = 1). In colonoscopy, discrete ulcers (n = 5), longitudinal ulcers (n = 1), erosions and/or small ulcers (n = 2), edematous mucosa (n = 2), and concurrent ulcerative colitis (n = 1) were identified. Patients with systemic lupus erythematosus with SLEDAI scores > or = 5, or with gastrointestinal symptoms, particularly those who present with abdominal pain or diarrhea should undergo colonoscopy, because these patients are likely to have mucosal damage in the colorectum.

  5. A randomized, controlled trial of interactive, multimedia software for patient colonoscopy education.

    PubMed

    Shaw, M J; Beebe, T J; Tomshine, P A; Adlis, S A; Cass, O W

    2001-02-01

    The purpose of our study was to assess the effectiveness of computer-assisted instruction (CAI) in patients having colonoscopies. We conducted a randomized, controlled trial in large, multispecialty clinic. Eighty-six patients were referred for colonoscopies. The interventions were standard education versus standard education plus CAI, and the outcome measures were anxiety, comprehension, and satisfaction. Computer-assisted instruction had no effect on patients' anxiety. The group receiving CAI demonstrated better overall comprehension (p < 0.001). However, Comprehension of certain aspects of serious complications and appropriate postsedation behavior were unaffected by educational method. Patients in the CAI group were more likely to indicate satisfaction with the amount of information provided when compared with the standard education counterparts (p = 0.001). Overall satisfaction was unaffected by educational method. Computer-assisted instruction for colonoscopy provided better comprehension and greater satisfaction with the adequacy of education than standard education. Computer-assisted instruction helps physicians meet their educational responsibilities with no decrement to the interpersonal aspects of the patient-physician relationship.

  6. New endoscopy advances to refine adenoma detection rate for colorectal cancer screening: None is the winner.

    PubMed

    Maida, Marcello; Camilleri, Salvatore; Manganaro, Michele; Garufi, Serena; Scarpulla, Giuseppe

    2017-10-15

    Colorectal cancer (CRC) is the third most common cancer in males and second in females, and globally the fourth cause for cancer death worldwide. Oncological screening of CRC has a major role in the management of the disease and it is mostly performed by colonoscopy. Anyway, effectiveness of endoscopic screening for CRC strictly depends on adequate detection and removal of potentially precancerous lesions, and accuracy of colonoscopy in detection of adenomas is still suboptimal. For this reason, several technological advances have been implemented in order to improve the diagnostic sensitivity of colonoscopy in adenoma detection. Among these: (1) Visual technologies such as chromoendoscopy and narrow band imaging; (2) optical innovation as high definition endoscopy, full-spectrum endoscopy or Third Eye Retroscope; and (3) mechanical advances as Cap assisted colonoscopy, Endocuff, Endoring and G-Eye endoscope. All these technologies advances have been tested over time by clinical studies with mixed results. Which of them is more likely to be successful in the next future?

  7. Telomere length and genetics are independent colorectal tumour risk factors in an evaluation of biomarkers in normal bowel.

    PubMed

    Fernandez-Rozadilla, Ceres; Kartsonaki, Christiana; Woolley, Connor; McClellan, Michael; Whittington, Deb; Horgan, Gareth; Leedham, Simon; Kriaucionis, Skirmantas; East, James; Tomlinson, Ian

    2018-03-06

    Colorectal cancer (CRC) screening might be improved by using a measure of prior risk to modulate screening intensity or the faecal immunochemical test threshold. Intermediate molecular biomarkers could aid risk prediction by capturing both known and unknown risk factors. We sampled normal bowel mucosa from the proximal colon, distal colon and rectum of 317 individuals undergoing colonoscopy. We defined cases as having a personal history of colorectal polyp(s)/cancer, and controls as having no history of colorectal neoplasia. Molecular analyses were performed for: telomere length (TL); global methylation; and the expression of genes in molecular pathways associated with colorectal tumourigenesis. We also calculated a polygenic risk score (PRS) based on CRC susceptibility polymorphisms. Bowel TL was significantly longer in cases than controls, but was not associated with blood TL. PRS was significantly and independently higher in cases. Hypermethylation showed a suggestive association with case:control status. No gene or pathway was differentially expressed between cases and controls. Gene expression often varied considerably between bowel locations. PRS and bowel TL (but not blood TL) may be clinically-useful predictors of CRC risk. Sample collection to assess these biomarkers is feasible in clinical practice, especially where population screening uses flexible sigmoidoscopy or colonoscopy.

  8. Predictors of Colorectal Cancer Screening Prior to Implementation of a Large Pragmatic Trial in Federally Qualified Health Centers.

    PubMed

    Petrik, Amanda F; Le, Thuy; Keast, Erin; Rivelli, Jennifer; Bigler, Keshia; Green, Beverly; Vollmer, William M; Coronado, Gloria

    2018-02-01

    Colorectal cancer screening can prevent cancer deaths. Federally qualified health centers serve a unique patient population that often is not screened. Knowing who in this environment is getting screened via fecal testing and via colonoscopy can assist in tailoring intervention to raise rates of colorectal cancer screening. We examined patient-level and neighborhood-level characteristics associated with being up to date with colorectal cancer screening guidelines. We also examined associations between these factors and being screened with a fecal test. We observed an increase in colorectal cancer screening rates from 2010 to 2015. Adjusted analyses revealed that the following factors were significantly associated with colorectal cancer screening: aged 65 or older, having any type of insurance, previous outpatient visits, and current or other preventive screenings. Among adults aged 50-75 who were up to date with colorectal cancer screening, factors associated with use of fecal testing, as opposed to colonoscopy, were: being younger, speaking a non-English language, being uninsured, having prior office visits, and having had a flu shot in past year. Our findings may inform clinic-based effort to raise rates of colorectal cancer screening, especially in the community clinic setting. ClinicalTrials.gov , NCT01742065.

  9. Organised colorectal cancer screening in Lampang Province, Thailand: preliminary results from a pilot implementation programme

    PubMed Central

    Khuhaprema, Thiravud; Sangrajrang, Suleeporn; Lalitwongsa, Somkiat; Chokvanitphong, Vanida; Raunroadroong, Tawarat; Ratanachu-ek, Tawee; Muwonge, Richard; Lucas, Eric; Wild, Christopher; Sankaranarayanan, Rengaswamy

    2014-01-01

    Objective Colorectal cancer (CRC) is the third-most and fifth-most common cancer in men and women, in Thailand. The increasing CRC incidence and mortality can be reduced by screening and treating adenomas and early cancers. A pilot CRC screening programme using immunochemical faecal occult blood testing (iFOBT) and colonoscopy for test-positives were implemented through the routine Government Health Services in Lampang Province, to inform the acceptability, feasibility and scaling-up of screening in Thailand. This report describes the implementation, coverage and performance indicators of this project. Design A target population aged 50–65 years was informed about and invited face to face to undergo CRC screening by community health workers (HWs). The HWs provided faecal sample collection kits and participants brought their samples to one of the primary health units or community hospitals where nurses performed iFOBT. iFOBT-positive persons were referred for colonoscopy at the Lampang cancer hospital, and endoscopic polypectomy/biopsies were performed according to the colonoscopic findings. Those with confirmed CRC received appropriate treatment. Results Of the 127 301 target population, 62.9% were screened using iFOBT between April 2011 and November 2012. Participation was higher among women (67.8%) than men (57.8%) and lower in 50–54 year-old persons than in 60–65-year-olds. Of those screened, 873 (1.1%) were found positive; positivity was higher in men (1.2%) than in women (1.0%). To date 627 (72.0%) iFOBT-positive persons have had colonoscopy in which 3.7% had CRC and 30.6% had adenomas. Conclusions The successful implementation of the pilot CRC screening with satisfactory process measures indicate the feasibility of scaling-up organised CRC screening through existing health services in Thailand. PMID:24435889

  10. Do patients undergo prostate examination while having a colonoscopy?

    PubMed Central

    Hammett, Tess; Hookey, Lawrence C; Kawakami, Jun

    2009-01-01

    OBJECTIVES: To determine the rate at which physicians report performing a digital rectal examination and comment on the prostate gland before performing colonoscopy in men 50 to 70 years of age. METHODS: A retrospective chart review of all men 50 to 70 years of age who had a colonoscopy in Kingston, Ontario, in 2005 was completed. It was noted whether each physician described performing a digital rectal examination before the colonoscopy, and if so, whether he or she commented on the prostate. RESULTS: In 2005, 846 eligible colonoscopies were performed by 17 physicians in Kingston, Ontario. In 29.2% of cases, the physician made no comment about having performed a digital rectal examination; in 55.8% of cases, the physician commented on having completed a digital rectal examination but said nothing about the prostate; and in 15.0% of cases, the physician made a comment regarding the prostate. No physician consistently commented on the prostate for all patients, and in no circumstances was direct referral to another physician or follow-up suggested. DISCUSSION: A colonoscopy presents an ideal opportunity for physicians to use a digital rectal examination to assess for prostate cancer. Physicians performing colonoscopies in men 50 to 70 years of age should pay special attention to the prostate while performing a digital rectal examination before colonoscopy. This novel concept may help maximize resources for cancer screening and could potentially increase the detection rate of clinically palpable prostate cancer. PMID:19172207

  11. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation.

    PubMed

    Parente, Fabrizio; Vailati, Cristian; Bargiggia, Stefano; Manes, Gianpiero; Fontana, Paola; Masci, Enzo; Arena, Monica; Spinzi, Giancarlo; Baccarin, Alessandra; Mazzoleni, Giorgia; Testoni, Pier Alberto

    2015-10-01

    Chronic constipation is a risk factor of inadequate bowel preparation for colonoscopy; however, no large clinical trials have been performed in this subgroup of patients. To compare bowel cleansing efficacy, tolerability and acceptability of 2-L polyethylene-glycol-citrate-simethicone (PEG-CS) plus 2-day bisacodyl (reinforced regimen) vs. 4-L PEG in patients with chronic constipation undergoing colonoscopy. Randomized, observer-blind, parallel group study. Adult outpatients undergoing colonoscopy were randomly allocated to 2-L PEG-CS/bisacodyl or 4-L PEG, taken as split regimens before colonoscopy. Quality of bowel preparation was assessed by the Ottawa Bowel Cleansing Scale (OBCS). The amount of foam/bubble interfering with colonic visualization was also measured. 400 patients were enrolled. There was no significant difference in successful cleansing (OBCS score ≤6): 80.2% in the 2-L PEG-CS/bisacodyl vs. 81.4% in the 4-L PEG group. Significantly more patients taking 2L PEG-CS/bisacodyl showed no or minimal foam/bubbles in all colonic segments (80% vs. 63%; p<0.001). 2-L PEG-CS/bisacodyl was significantly more acceptable for ease of administration (p<0.001), willingness to repeat (p<0.001) and showed better compliance (p=0.002). Split 2-L PEG-CS plus bisacodyl was not superior to split 4-L PEG for colonoscopy bowel cleansing in patients with chronic constipation; however, it performed better than the standard regimen in terms of colonic mucosa visualization, patient acceptance and compliance. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  12. Using resource modelling to inform decision making and service planning: the case of colorectal cancer screening in Ireland

    PubMed Central

    2013-01-01

    Background Organised colorectal cancer screening is likely to be cost-effective, but cost-effectiveness results alone may not help policy makers to make decisions about programme feasibility or service providers to plan programme delivery. For these purposes, estimates of the impact on the health services of actually introducing screening in the target population would be helpful. However, these types of analyses are rarely reported. As an illustration of such an approach, we estimated annual health service resource requirements and health outcomes over the first decade of a population-based colorectal cancer screening programme in Ireland. Methods A Markov state-transition model of colorectal neoplasia natural history was used. Three core screening scenarios were considered: (a) flexible sigmoidoscopy (FSIG) once at age 60, (b) biennial guaiac-based faecal occult blood tests (gFOBT) at 55–74 years, and (c) biennial faecal immunochemical tests (FIT) at 55–74 years. Three alternative FIT roll-out scenarios were also investigated relating to age-restricted screening (55–64 years) and staggered age-based roll-out across the 55–74 age group. Parameter estimates were derived from literature review, existing screening programmes, and expert opinion. Results were expressed in relation to the 2008 population (4.4 million people, of whom 700,800 were aged 55–74). Results FIT-based screening would deliver the greatest health benefits, averting 164 colorectal cancer cases and 272 deaths in year 10 of the programme. Capacity would be required for 11,095-14,820 diagnostic and surveillance colonoscopies annually, compared to 381–1,053 with FSIG-based, and 967–1,300 with gFOBT-based, screening. With FIT, in year 10, these colonoscopies would result in 62 hospital admissions for abdominal bleeding, 27 bowel perforations and one death. Resource requirements for pathology, diagnostic radiology, radiotherapy and colorectal resection were highest for FIT. Estimates depended on screening uptake. Alternative FIT roll-out scenarios had lower resource requirements. Conclusions While FIT-based screening would quite quickly generate attractive health outcomes, it has heavy resource requirements. These could impact on the feasibility of a programme based on this screening modality. Staggered age-based roll-out would allow time to increase endoscopy capacity to meet programme requirements. Resource modelling of this type complements conventional cost-effectiveness analyses and can help inform policy making and service planning. PMID:23510135

  13. A Comparative Study of Treatment-Emergent Adverse Events Following Use of Common Bowel Preparations Among a Colonoscopy Screening Population: Results from a Post-Marketing Observational Study.

    PubMed

    Anastassopoulos, Kathryn; Farraye, Francis A; Knight, Tyler; Colman, Sam; Cleveland, Mark vB; Pelham, Russell W

    2016-10-01

    Colonoscopy may be one of the most frequent elective procedures in older adults and is associated with a low occurrence of complications. However, reduction of risks attributable to the bowel preparation may be achieved with the use of effective and safer products. The aim of this study was to examine the incidence of treatment-emergent adverse events (TEAEs) associated with SUPREP(®) [oral sulfate solution (OSS)] and other common prescription bowel preparations (non-OSS). This real-world, observational study used de-identified health insurance claims and laboratory results to identify TEAEs in the 3 months following screening colonoscopy in adults with a prescription for a bowel preparation in the prior 60 days. The unadjusted and adjusted (controlling for patient risk factors) cumulative incidences of TEAEs were estimated using Kaplan-Meier and Poisson regression, respectively. Among patients ≥45 years, the overall cumulative incidence was significantly lower (p < 0.001) in the OSS cohort than in the non-OSS cohort (unadjusted: 2.31 vs. 2.89 %; adjusted: 1.61 vs. 1.95 %), with significantly lower acute cardiac conditions (1.56 vs. 1.90 %; p < 0.001), renal failure/other serious renal diseases (OSS: 0.21 %, non-OSS: 0.32 %; p < 0.001), and serum electrolyte abnormalities (OSS: 0.39 %, non-OSS: 0.49 %; p = 0.017). There were no significant differences between cohorts in death, seizure disorders, aggravation of gout, and ischemic colitis. Results were similar in the adjusted cumulative incidences. In actual use, the overall cumulative incidence of TEAEs was significantly lower in the OSS cohort, demonstrating that OSS is as safe as, or possibly safer than, non-OSS prescription bowel preparations.

  14. The influence of health literacy on comprehension of a colonoscopy preparation information leaflet

    PubMed Central

    Smith, Samuel G.; von Wagner, Christian; McGregor, Lesley M.; Curtis, Laura M.; Wilson, Elizabeth A. H.; Serper, Marina; Wolf, Michael S.

    2012-01-01

    BACKGROUND Successful bowel preparation is important for safe, efficacious, cost-effective colonoscopy procedures, however poor preparation is common. OBJECTIVE We sought to determine if there was an association between health literacy and comprehension of typical written instructions on how to prepare for a colonoscopy to enable more targeted interventions in this area. DESIGN Cross-sectional observational study SETTING Primary care clinics and federally qualified health centres in Chicago, Illinois. PATIENTS 764 participants (mean age: 63 years; Standard Deviation: 5.42) were recruited. The sample was from a mixed socio-demographic background and 71.9% of the participants were classified as having adequate health literacy scores. INTERVENTION 764 participants were presented with an information leaflet outlining the bowel preparatory instructions for colonoscopy. MAIN OUTCOME MEASURES Five questions assessing comprehension of the instructions in an ‘open book’ test. RESULTS Comprehension scores on the bowel preparation items were low. The mean number of items correctly answered was 3.2 (Standard Deviation, 1.2) out of a possible 5. Comprehensions scores overall and for each individual item differed significantly by health literacy level (all p<0.001). After controlling for gender, age, race, socio-economic status and previous colonoscopy experience in a multivariable model, health literacy was a significant predictor of comprehension (inadequate vs. adequate: β = −0.2; p < 0.001; marginal vs. adequate: β = −0.2; p < 0.001). LIMITATIONS The outcome represents a simulated task and not actual comprehension of preparation instructions for participants’ own recommended behavior. CONCLUSIONS Comprehension of a written colonoscopy preparation leaflet was generally low and significantly more so among people with low health literacy. Poor comprehension has implications for the safety and economic impact of gastroenterological procedures such as colonoscopy. Therefore future interventions should aim to improve comprehension of complex medical information by reducing literacy-related barriers. PMID:22965407

  15. Patient-controlled analgesia with inhaled methoxyflurane versus conventional endoscopist-provided sedation for colonoscopy: a randomized multicenter trial.

    PubMed

    Nguyen, Nam Q; Toscano, Leanne; Lawrence, Matthew; Moore, James; Holloway, Richard H; Bartholomeusz, Dylan; Lidums, Ilmars; Tam, William; Roberts-Thomson, Ian C; Mahesh, Venkataswamy N; Debreceni, Tamara L; Schoeman, Mark N

    2013-12-01

    Inhaled methoxyflurane (Penthrox, Medical Device International, Melbourne, Australia) has been used extensively in Australasia (Australia and New Zealand) to manage trauma-related pain. The aim is to evaluate the efficacy, safety, and outcome of Penthrox for colonoscopy. Prospective randomized study. Three tertiary endoscopic centers. Two hundred fifty-one patients were randomized to receive either Penthrox (n = 125, 70 men, 51.4 ± 1.1 years old) or intravenous midazolam and fentanyl (M&F; n = 126, 72 men, 54.9 ± 1.1 years old) during colonoscopy. Discomfort (visual analogue scale [VAS] pain score), anxiety (State-Trait Anxiety Inventory Form Y [STAI-Y] anxiety score), colonoscopy performance, adverse events, and recovery time. Precolonoscopy VAS pain and STAI-Y scores were comparable between the 2 groups. There were no differences between groups in (1) pain VAS or STAI Y-1 anxiety scores during or immediately after colonoscopy, (2) procedural success rate (Penthrox: 121/125 vs M&F: 124/126), (3) hypotension during colonoscopy (7/125 vs 8/126), (4) tachycardia (5/125 vs 3/126), (5) cecal arrival time (8 ± 1 vs 8 ± 1 minutes), or (6) polyp detection rate (30/125 vs 43/126). Additional intravenous sedation was required in 10 patients (8%) who received Penthrox. Patients receiving Penthrox alone had no desaturation (oxygen saturation [SaO(2)] < 90%) events (0/115 vs 5/126; P = .03), awoke quicker (3 ± 0 vs 19 ± 1 minutes; P < .001) and were ready for discharge earlier (37 ± 1 vs 66 ± 2 minutes; P < .001) than those receiving intravenous M&F. Inhaled Penthrox is not yet available in the United States and Europe. Patient-controlled analgesia with inhaled Penthrox is feasible and as effective as conventional sedation for colonoscopy with shorter recovery time, is not associated with respiratory depression, and does not influence the procedural success and polyp detection. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. Motivation-based intervention to promote colonoscopy screening: An integration of a fear management model and motivational interviewing

    PubMed Central

    Pengchit, Watcharaporn; Walters, Scott T.; Simmons, Rebecca G.; Kohlmann, Wendy; Burt, Randall W.; Schwartz, Marc D.; Kinney, Anita Y.

    2011-01-01

    Colorectal cancer (CRC) screening rates have been low despite effectiveness of screening in reducing CRC mortality. This article outlines the theoretical background and development of an innovative, telephone-based risk communication designed to promote screening among individuals at increased risk for familial CRC. This ongoing intervention integrates the Extended Parallel Process Model of fear management and the motivational interviewing counselling style. Tailoring and implementation intentions are incorporated. The primary outcome is self-reported colonoscopy within nine months following intervention. If proven effective, the remote intervention could be broadly disseminated to individuals at increased familial CRC risk, especially those in geographically underserved areas. PMID:21464114

  17. Two methods of Haustral fold detection from computed tomographic virtual colonoscopy images

    NASA Astrophysics Data System (ADS)

    Chowdhury, Ananda S.; Tan, Sovira; Yao, Jianhua; Linguraru, Marius G.; Summers, Ronald M.

    2009-02-01

    Virtual colonoscopy (VC) has gained popularity as a new colon diagnostic method over the last decade. VC is a new, less invasive alternative to the usually practiced optical colonoscopy for colorectal polyp and cancer screening, the second major cause of cancer related deaths in industrial nations. Haustral (colonic) folds serve as important landmarks for virtual endoscopic navigation in the existing computer-aided-diagnosis (CAD) system. In this paper, we propose and compare two different methods of haustral fold detection from volumetric computed tomographic virtual colonoscopy images. The colon lumen is segmented from the input using modified region growing and fuzzy connectedness. The first method for fold detection uses a level set that evolves on a mesh representation of the colon surface. The colon surface is obtained from the segmented colon lumen using the Marching Cubes algorithm. The second method for fold detection, based on a combination of heat diffusion and fuzzy c-means algorithm, is employed on the segmented colon volume. Folds obtained on the colon volume using this method are then transferred to the corresponding colon surface. After experimentation with different datasets, results are found to be promising. The results also demonstrate that the first method has a tendency of slight under-segmentation while the second method tends to slightly over-segment the folds.

  18. A Prospective Randomized Controlled Trial of AJG522 versus Standard PEG + E as Bowel Preparation for Colonoscopy

    PubMed Central

    Sagawa, Toshihiko; Tomizawa, Taku; Mizuide, Masafumi; Yasuoka, Hidetoshi; Shimoyama, Yasuyuki; Kakizaki, Satoru; Kawamura, Osamu; Kusano, Motoyasu; Yamada, Masanobu

    2015-01-01

    Polyethylene glycol- (PEG-) based bowel preparations for colonoscopies are often poorly tolerated due to the large volumes of fluid intake required. We compared low-volume “modified” PEG + ascorbic acid (AJG522) with standard PEG with electrolytes (PEG + E) in addition to a stimulant laxative and an agent to improve bowel function for the bowel cleansing before colonoscopy to evaluate its efficacy, safety, and acceptability. Outpatients scheduled to undergo colonoscopy were randomized to receive either AJG522 or PEG + E. Bowel cleansing conditions were assessed via macroscopic fecal findings by blinded and independent investigators. A survey of the patients' feedback regarding the preparation was conducted by questionnaire. Successful cleansing was achieved in all cases, except for 4 cases in the PEG + E group, at 3 hours after taking the preparation. The fecal properties were significantly clearer in the AJG522 group than in the PEG + E group at 2 hours after taking each preparation (P = 0.013). Although the total liquid volume of the bowel preparation was not reduced, the AJG522 preparation could significantly reduce the required volume of the preparation (P < 0.0001). Moreover, the patients in the AJG522 group had better acceptability (P = 0.010). There were no significant differences in the safety profiles between groups (UMIN000013892). PMID:25688357

  19. The big picture: does colonoscopy work?

    PubMed

    Hewett, David G; Rex, Douglas K

    2015-04-01

    Colonoscopy for average-risk colorectal cancer screening has transformed the practice of gastrointestinal medicine in the United States. However, although the dominant screening strategy, its use is not supported by randomized controlled trials. Observational data do support a protective effect of colonoscopy and polypectomy on colorectal cancer incidence and mortality, but the level of protection in the proximal colon is variable and operator-dependent. Colonoscopy by high-level detectors remains highly effective, and ongoing quality improvement initiatives should consider regulatory factors that motivate changes in physician behavior. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Haptic device for colonoscopy training simulator.

    PubMed

    Kwon, Jun Yong; Woo, Hyun Soo; Lee, Doo Yong

    2005-01-01

    A new 2-DOF haptic device for colonoscopy training simulator employing flexible endoscopes, is developed. The user operates the device in translational and roll directions. The developed folding guides of the device keep the endoscope tube straight. This helps transmit large decoupled forces of the colonoscopy simulation to the user. The device also includes a mechanism to detect jiggling motion of the scopes to allow users to practice this important skill of the colonoscopy. The device includes PD controller to compensate the inertia and friction effects. This provides the users with better transparent sensation of the simulation.

  1. Colonoscopy can miss diverticula of the left colon identified by barium enema.

    PubMed

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-04-21

    To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (< 70 or ≥ 70 years), sex, and colon location. The number of diverticula was counted, and the detection ratio was calculated. Colonic diverticula were observed in 46 patients with barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P < 0.01). Compared with barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.

  2. Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm

    PubMed Central

    Woo, Jaehong; Choi, Jae Hyuk; Seo, Jong Tae

    2017-01-01

    Purpose Colonoscopy is one of the most effective diagnostic and therapeutic tools for colorectal diseases. We aim to propose a master-slave robotic colonoscopy that is controllable in remote site using conventional colonoscopy. Materials and Methods The master and slave robot were developed to use conventional flexible colonoscopy. The robotic colonoscopic procedure was performed using a colonoscope training model by one expert endoscopist and two unexperienced engineers. To provide the haptic sensation, the insertion force and the rotating torque were measured and sent to the master robot. Results A slave robot was developed to hold the colonoscopy and its knob, and perform insertion, rotation, and two tilting motions of colonoscope. A master robot was designed to teach motions of the slave robot. These measured force and torque were scaled down by one tenth to provide the operator with some reflection force and torque at the haptic device. The haptic sensation and feedback system was successful and helpful to feel the constrained force or torque in colon. The insertion time using robotic system decreased with repeated procedures. Conclusion This work proposed a robotic approach for colonoscopy using haptic feedback algorithm, and this robotic device would effectively perform colonoscopy with reduced burden and comparable safety for patients in remote site. PMID:27873506

  3. Providing Hospitalized Patients With an Educational Booklet Increases the Quality of Colonoscopy Bowel Preparation.

    PubMed

    Ergen, William F; Pasricha, Trisha; Hubbard, Francie J; Higginbotham, Tina; Givens, Tonya; Slaughter, James C; Obstein, Keith L

    2016-06-01

    Inadequate bowel preparation is a problem frequently encountered by gastroenterologists who perform colonoscopies on hospitalized patients. A method is needed to increase the quality of bowel preparation in inpatients. An educational booklet has been shown to increase the overall quality of bowel preparation for outpatients. We performed a prospective study to evaluate the effects of an educational booklet on the quality of bowel preparation in a group of hospitalized patients. We performed a randomized, single-blind, controlled trial of all inpatients at a tertiary care medical center scheduled for inpatient colonoscopy from October 2013 through March 2014. They were randomly assigned to groups that were (n = 45) or were not (controls, n = 40) given the booklet before bowel preparation the evening before their colonoscopy. All patients received a standard bowel preparation (clear liquid diet the day before the procedure, followed by split-dose GoLYTELY). At the colonoscopy, the Boston Bowel preparation scale (BBPS) was used to assess bowel preparation. The primary outcome measure was adequate bowel preparation (a total BBPS score ≥6 with all segment scores ≥2). Secondary outcomes assessed included total BBPS score, BBPS segment score, and a total BBPS score of 0. There were no differences between the groups in age, race, sex, body mass index, history of colonoscopy, history of polyps, or time of colonoscopy. Twenty-eight patients who received the booklet (62%) and 14 who did not (35%) had an adequate bowel preparation (P = .012). The number needed to treat to attain adequate bowel preparation was 4. After adjusting for age and history of prior colonoscopies, the odds of achieving an adequate bowel preparation and a higher total BBPS score after receipt of the booklet were 3.14 (95% confidence interval, 1.29-7.83) and 2.27 (95% confidence interval, 1.05-4.88), respectively. Three patients in the booklet group and 9 in the no-booklet group had a BBPS score of 0 (P = .036). The mean BBPS segment score was greater for the booklet group than the no-booklet group (right colon, P = .097; transverse colon, P = .023; left colon, P = .045). In a randomized controlled trial, we found that providing hospitalized patients with an educational booklet on colonoscopy preparation increases the odds of a quality bowel preparation more than 2-fold. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  4. Bowel Prep Quality in Patients of Low Socioeconomic Status Undergoing Screening Colonoscopy with Patient Navigation

    ERIC Educational Resources Information Center

    Miller, Sarah Johanna; Itzkowitz, Steven H.; Shah, Brijen; Jandorf, Lina

    2016-01-01

    The effectiveness of colonoscopy is directly affected by the quality of the patient's bowel preparation. Patients with lower socioeconomic status (SES) are at increased risk of having suboptimal bowel prep quality. Patient navigators can play a key role in clarifying bowel prep instructions. The aim of the present study was to examine the quality…

  5. Quality assurance for gastrointestinal endoscopy.

    PubMed

    Allen, John I

    2012-09-01

    This review concerns quality assurance for gastrointestinal endoscopic procedures, especially colonoscopy and will emphasize research and guidelines published since January 2011. Important articles from previous years have been included for background. Critical lapses in endoscope processing and administration of intravenous sedation alerted us to the infection risk of endoscopy. Increases in cost of colonoscopy, evidence for overuse and studies demonstrating missed cancers have led some to question the value of endoscopy. Despite these setbacks, the National Polyp Study (NPS) consortium published their long-term follow-up of the original NPS patients and confirmed that colonoscopy with polyp removal can reduce the risk of colorectal cancer for an extended period. In this article, we will focus on ways to improve the value of outpatient colonoscopy. The United States national quality improvement agenda recently became organized into a more coordinated effort spearheaded by several public and private entities. They comprise the infrastructure by which performance measures are developed and implemented as accountability standards. Understanding wherein a gastroenterology (GI) practice fits into this infrastructure and learning ways we can improve our endoscopic practice is important for physicians who provide this vital service to patients. This article will provide a roadmap for developing a quality assurance program for endoscopic practice.

  6. Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs standard colonoscopy

    PubMed Central

    Tee, Hoi-Poh; Corte, Crispin; Al-Ghamdi, Hamdan; Prakoso, Emilia; Darke, John; Chettiar, Raman; Rahman, Wassim; Davison, Scott; Griffin, Sean P; Selby, Warwick S; Kaffes, Arthur J

    2010-01-01

    AIM: To study the significance of cap-fitted colonoscopy in improving cecal intubation time and polyp detection rate. METHODS: This study was a prospective randomized controlled trial conducted from March 2008 to February 2009 in a tertiary referral hospital at Sydney. The primary end point was cecal intubation time and the secondary endpoint was polyp detection rate. Consecutive cases of total colonoscopy over a 1-year period were recruited. Randomization into either standard colonoscopy (SC) or cap-assisted colonoscopy (CAC) was performed after consent was obtained. For cases randomized to CAC, one of the three sizes of cap was used: D-201-15004 (with a diameter of 15.3 mm), D-201-14304 (14.6 mm) and D-201-12704 (13.0 mm). All of these caps were produced by Olympus Medical Systems, Japan. Independent predictors for faster cecal time and better polyp detection rate were also determined from this study. RESULTS: There were 200 cases in each group. There was no significant difference in terms of demographic characteristics between the two groups. CAC, when compared to the SC group, had no significant difference in terms of cecal intubation rate (96.0% vs 97.0%, P = 0.40) and time (9.94 ± 7.05 min vs 10.34 ± 6.82 min, P = 0.21), or polyp detection rate (32.8% vs 31.3%, P = 0.75). On the subgroup analysis, there was no significant difference in terms of cecal intubation time by trainees (88.1% vs 84.8%, P = 0.40), ileal intubation rate (82.5% vs 79.0%, P = 0.38) or total colonoscopy time (23.24 ± 13.95 min vs 22.56 ± 9.94 min, P = 0.88). On multivariate analysis, the independent determinants of faster cecal time were consultant-performed procedures (P < 0.001), male patients (P < 0.001), non-usage of hyoscine (P < 0.001) and better bowel preparation (P = 0.01). The determinants of better polyp detection rate were older age (P < 0.001), no history of previous abdominal surgery (P = 0.04), patients not having esophagogastroduodenoscopy in the same setting (P = 0.003), trainee-performed procedures (P = 0.01), usage of hyoscine (P = 0.01) and procedures performed for polyp follow-up (P = 0.01). The limitations of the study were that it was a single-center experience, no blinding was possible, and there were a large number of endoscopists. CONCLUSION: CAC did not significantly different from SC in term of cecal intubation time and polyp detection rate. PMID:20712051

  7. Cancer preventive services, socioeconomic status, and the Affordable Care Act.

    PubMed

    Cooper, Gregory S; Kou, Tzuyung Doug; Dor, Avi; Koroukian, Siran M; Schluchter, Mark D

    2017-05-01

    Out-of-pocket expenditures are thought to be an important barrier to the receipt of cancer preventive services, especially for those of a lower socioeconomic status (SES). The Affordable Care Act (ACA) eliminated out-of-pocket expenditures for recommended services, including mammography and colonoscopy. The objective of this study was to determine changes in the uptake of mammography and colonoscopy among fee-for-service Medicare beneficiaries before and after ACA implementation. Using Medicare claims data, this study identified women who were 70 years old or older and had not undergone mammography in the previous 2 years and men and women who were 70 years old or older, were at increased risk for colorectal cancer, and had not undergone colonoscopy in the past 5 years. The receipt of procedures in the 2-year period before the ACA's implementation (2009-2010) and after its implementation (2011 to September 2012) was also identified. Multivariate generalized estimating equation models were used to determine the independent association and county-level quartile of median income and education with the receipt of testing. For mammography, a lower SES quartile was associated with less uptake, but the post-ACA disparities were smaller than those in the pre-ACA period. In addition, mammography rates increased from the pre-ACA period to the post-ACA period in all SES quartiles. For colonoscopy, in both the pre- and post-ACA periods, there was an association between uptake and educational level and, to some extent, income. However, there were no appreciable changes in colonoscopy and SES after implementation of the ACA. The removal of out-of-pocket expenditures may overcome a barrier to the receipt of recommended preventive services, but for colonoscopy, other procedural factors may remain as deterrents. Cancer 2017;123:1585-1589. © 2017 American Cancer Society. © 2017 American Cancer Society.

  8. Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy.

    PubMed

    Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele

    2013-09-07

    To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy.

  9. [Colonic diverticular disease: diagnosis and therapy].

    PubMed

    Lakatos, László; Lakatos, Péter László

    2012-02-12

    Colonic diverticular disease is one of the most common gastrointestinal disorders in the Western world, affecting approximately 50% of the population above the age of 70 years. Symptoms develop only in about one quarter of the affected individuals with complications in one-third of the symptomatic patients. Diagnosis is mostly confirmed by colonoscopy. Abdominal CT is the most sensitive for the diagnosis of complicated severe diverticulitis, while colonoscopy or in severe cases angiography may be performed in bleeding patients. Initial therapy of non-complicated symptomatic diverticulitis includes antibiotics and more recently non-absorbable antibiotics. In complicated cases should be treated with broad spectrum i.v. antibiotics, however surgery may became necessary in a minority of the cases. The proportion of patients needing acute surgical intervention has decreased in the last decades with the advancement of conservative management including medical therapy, endoscopy and imaging techniques and the indication of elective was also changed.

  10. [Development and validation of quality standards for colonoscopy].

    PubMed

    Sánchez Del Río, Antonio; Baudet, Juan Salvador; Naranjo Rodríguez, Antonio; Campo Fernández de Los Ríos, Rafael; Salces Franco, Inmaculada; Aparicio Tormo, Jose Ramón; Sánchez Muñoz, Diego; Llach, Joseph; Hervás Molina, Antonio; Parra-Blanco, Adolfo; Díaz Acosta, Juan Antonio

    2010-01-30

    Before starting programs for colorectal cancer screening it is necessary to evaluate the quality of colonoscopy. Our objectives were to develop a group of quality indicators of colonoscopy easily applicable and to determine the variability of their achievement. After reviewing the bibliography we prepared 21 potential indicators of quality that were submitted to a process of selection in which we measured their facial validity, content validity, reliability and viability of their measurement. We estimated the variability of their achievement by means of the coefficient of variability (CV) and the variability of the achievement of the standards by means of chi(2). Six indicators overcome the selection process: informed consent, medication administered, completed colonoscopy, complications, every polyp removed and recovered, and adenoma detection rate in patients older than 50 years. 1928 colonoscopies were included from eight endoscopy units. Every unit included the same number of colonoscopies selected by means of simple random sampling with substitution. There was an important variability in the achievement of some indicators and standards: medication administered (CV 43%, p<0.01), complications registered (CV 37%, p<0.01), every polyp removed and recovered (CV 12%, p<0.01) and adenoma detection rate in older than fifty years (CV 2%, p<0.01). We have validated six quality indicators for colonoscopy which are easily measurable. An important variability exists in the achievement of some indicators and standards. Our data highlight the importance of the development of continuous quality improvement programmes for colonoscopy before starting colorectal cancer screening. Copyright (c) 2009 Elsevier España, S.L. All rights reserved.

  11. Evaluation of the colorectal cancer screening Programme in the Basque Country (Spain) and its effectiveness based on the Miscan-colon model.

    PubMed

    Idigoras, I; Arrospide, A; Portillo, I; Arana-Arri, E; Martínez-Indart, L; Mar, J; de Koning, H J; Lastra, R; Soto-Gordoa, M; van der Meulen, M; Lansdorp-Vogelaar, I

    2017-08-01

    The population-based Basque Colorectal Cancer (CRC) Screening Programme started in 2009 with a biennial immunochemical quantitative test (FIT) biennial and colonoscopy under sedation in positive cases. The population target of 586,700 residents was from 50 to 69 years old and the total coverage was reached at the beginning of 2014. The aim of our study was to determine possible scenarios in terms of incidence, mortality and reduction of Life-years-Lost (L-y-L) in the medium and long term of CRC. Invitations were sent out by the Programme from 2009 to 2014, with combined organizational strategies. Simulation was done by MISCAN-colon (Microsimulation Screening Analysis) over 30 years comparing the results of screening vs no-screening, taking the population-based Cancer Registry into account. Lifetime population and real data from the Programme were used from 2008 to 2012. The model was run differentially for men and women. 924,416 invitations were sent out from 2009 to 2014. The average participation rate was 68.4%, CRC detection rate was 3.4% and the Advanced Adenoma detection rate was 24.0‰, with differences observed in sex and age. Future scenarios showed a higher decrease of incidence (17.2% vs 14.7%), mortality (28.1% vs 22.4%) and L-y-L (22.6% vs 18.4%) in men than women in 2030. The Basque Country CRC Programme results are aligned to its strategy and comparable to other programmes. MISCAN model was found to be a useful tool to predict the benefits of the programme in the future. The effectiveness of the Programme has not been formally established as case control studies are required to determine long term benefits from the screening strategy.

  12. Population-based programs for increasing colorectal cancer screening in the United States.

    PubMed

    Verma, Manisha; Sarfaty, Mona; Brooks, Durado; Wender, Richard C

    2015-01-01

    Answer questions and earn CME/CNE Screening to detect polyps or cancer at an early stage has been shown to produce better outcomes in colorectal cancer (CRC). Programs with a population-based approach can reach a large majority of the eligible population and can offer cost-effective interventions with the potential benefit of maximizing early cancer detection and prevention using a complete follow-up plan. The purpose of this review was to summarize the key features of population-based programs to increase CRC screening in the United States. A search was conducted in the SCOPUS, OvidSP, and PubMed databases. The authors selected published reports of population-based programs that met at least 5 of the 6 International Agency for Research on Cancer (IARC) criteria for cancer prevention and were known to the National Colorectal Cancer Roundtable. Interventions at the level of individual practices were not included in this review. IARC cancer prevention criteria served as a framework to assess the effective processes and elements of a population-based program. Eight programs were included in this review. Half of the programs met all IARC criteria, and all programs led to improvements in screening rates. The rate of colonoscopy after a positive stool test was heterogeneous among programs. Different population-based strategies were used to promote these screening programs, including system-based, provider-based, patient-based, and media-based strategies. Treatment of identified cancer cases was not included explicitly in 4 programs but was offered through routine medical care. Evidence-based methods for promoting CRC screening at a population level can guide the development of future approaches in health care prevention. The key elements of a successful population-based approach include adherence to the 6 IARC criteria and 4 additional elements (an identified external funding source, a structured policy for positive fecal occult blood test results and confirmed cancer cases, outreach activities for recruitment and patient education, and an established rescreening process). © 2015 American Cancer Society.

  13. Anesthesiology and gastroenterology.

    PubMed

    de Villiers, Willem J S

    2009-03-01

    A successful population-based colorectal cancer screening requires efficient colonoscopy practices that incorporate high throughput, safety, and patient satisfaction. There are several different modalities of nonanesthesiologist-administered sedation currently available and in development that may fulfill these requirements. Modern-day gastroenterology endoscopic procedures are complex and demand the full attention of the attending gastroenterologist and the complete cooperation of the patient. Many of these procedures will also require the anesthesiologist's knowledge, skills, abilities, and experience to ensure optimal procedure results and good patient outcomes. The goal of this review is (1) to provide a gastroenterology perspective on the use of propofol in gastroenterology endoscopic practice, and (2) to describe newer GI endoscopy procedures that gastroenterologists perform that might involve anesthesiologists.

  14. Similar fecal immunochemical test results in screening and referral colorectal cancer

    PubMed Central

    van Turenhout, Sietze T; van Rossum, Leo GM; Oort, Frank A; Laheij, Robert JF; van Rijn, Anne F; Terhaar sive Droste, Jochim S; Fockens, Paul; van der Hulst, René WM; Bouman, Anneke A; Jansen, Jan BMJ; Meijer, Gerrit A; Dekker, Evelien; Mulder, Chris JJ

    2012-01-01

    AIM: To improve the interpretation of fecal immunochemical test (FIT) results in colorectal cancer (CRC) cases from screening and referral cohorts. METHODS: In this comparative observational study, two prospective cohorts of CRC cases were compared. The first cohort was obtained from 10 322 average risk subjects invited for CRC screening with FIT, of which, only subjects with a positive FIT were referred for colonoscopy. The second cohort was obtained from 3637 subjects scheduled for elective colonoscopy with a positive FIT result. The same FIT and positivity threshold (OC sensor; ≥ 50 ng/mL) was used in both cohorts. Colonoscopy was performed in all referral subjects and in FIT positive screening subjects. All CRC cases were selected from both cohorts. Outcome measurements were mean FIT results and FIT scores per tissue tumor stage (T stage). RESULTS: One hundred and eighteen patients with CRC were included in the present study: 28 cases obtained from the screening cohort (64% male; mean age 65 years, SD 6.5) and 90 cases obtained from the referral cohort (58% male; mean age 69 years, SD 9.8). The mean FIT results found were higher in the referral cohort (829 ± 302 ng/mL vs 613 ± 368 ng/mL, P = 0.02). Tissue tumor stage (T stage) distribution was different between both populations [screening population: 13 (46%) T1, eight (29%) T2, six (21%) T3, one (4%) T4 carcinoma; referral population: 12 (13%) T1, 22 (24%) T2, 52 (58%) T3, four (4%) T4 carcinoma], and higher T stage was significantly associated with higher FIT results (P < 0.001). Per tumor stage, no significant difference in mean FIT results was observed (screening vs referral: T1 498 ± 382 ng/mL vs 725 ± 374 ng/mL, P = 0.22; T2 787 ± 303 ng/mL vs 794 ± 341 ng/mL, P = 0.79; T3 563 ± 368 ng/mL vs 870 ± 258 ng/mL, P = 0.13; T4 not available). After correction for T stage in logistic regression analysis, no significant differences in mean FIT results were observed between both types of cohorts (P = 0.10). CONCLUSION: Differences in T stage distribution largely explain differences in FIT results between screening and referral cohorts. Therefore, FIT results should be reported according to T stage. PMID:23082056

  15. A competency framework for colonoscopy training derived from cognitive task analysis techniques and expert review.

    PubMed

    Zupanc, Christine M; Burgess-Limerick, Robin; Hill, Andrew; Riek, Stephan; Wallis, Guy M; Plooy, Annaliese M; Horswill, Mark S; Watson, Marcus O; Hewett, David G

    2015-12-01

    Colonoscopy is a difficult cognitive-perceptual-motor task. Designing an appropriate instructional program for such a task requires an understanding of the knowledge, skills and attitudes underpinning the competency required to perform the task. Cognitive task analysis techniques provide an empirical means of deriving this information. Video recording and a think-aloud protocol were conducted while 20 experienced endoscopists performed colonoscopy procedures. "Cued-recall" interviews were also carried out post-procedure with nine of the endoscopists. Analysis of the resulting transcripts employed the constant comparative coding method within a grounded theory framework. The resulting draft competency framework was modified after review during semi-structured interviews conducted with six expert endoscopists. The proposed colonoscopy competency framework consists of twenty-seven skill, knowledge and attitude components, grouped into six categories (clinical knowledge; colonoscope handling; situation awareness; heuristics and strategies; clinical reasoning; and intra- and inter-personal). The colonoscopy competency framework provides a principled basis for the design of a training program, and for the design of formative assessment to gauge progress towards attaining the knowledge, skills and attitudes underpinning the achievement of colonoscopy competence.

  16. Nutritional deficiency during colonoscopy preparation: the forgotten iatrogeny.

    PubMed

    Nunes, Gonçalo; Barata, Ana Teresa; Santos, Carla Adriana; Patita, Marta; Fonseca, Jorge

    2018-05-01

    bowel preparation for colonoscopy induces a semi-fasting state, with a potential negative impact on fragile patients. The present study aims to quantify nutritional deficiency during colonoscopy preparation. this was an observational and cross-sectional study. A convenience sample was obtained that included adults that underwent colonoscopy after bowel preparation with Klean-Prep® according to the center protocol. Anthropometric evaluation was performed and nutritional deficiency was calculated via the quantification of energy and protein intake during the 48 hours prior to the examination which was compared with the individuals' needs. The association between nutritional deficiency with the quality of bowel preparation, age and status (hospitalized/ambulatory) was evaluated. the study included 131 patients aged 21-91 years (mean 63.6 ± 13.2 years); 73 cases were male. Malnutrition reached 67.2% using specific anthropometric tools. A median preparation quality of six points was found when the Boston Bowel Preparation Scale was considered. The mean intake 48 hours prior to the procedure was 1,795 kcal and 100 g of protein. A daily energy intake of less than 50% of the individual needs was observed in 88 patients and less than 25% in 29 cases. The mean energy and protein deficiency were 59% (p < 0.01) and 45% (p < 0.01), and there was no correlation with preparation quality (p > 0.05). Nutritional defiency is similar in hospitalized and ambulatory patients (p > 0.05), but higher in older individuals (p = 0.04). nutritional deficiency during colonoscopy preparation was significant, more so in older patients, and there was no correlation with the quality of bowel preparation. We conclude that bowel preparation regimens should be reformulated with an improved nutritional intake and the inclusion of nutritional supplements without residues.

  17. Written instructions to patients to confirm pathology results: is this effective in the transmission of results?

    PubMed

    Patwardhan, Ashwin; Wilkins, Simon; Staples, Margaret; McMurrick, Paul J

    2018-05-01

    Bowel cancer is the second most common internal malignancy in Australia. Bowel cancer is suited to community screening methods such as faecal occult blood testing and colonoscopy. Typical reporting of histopathology results after colonoscopy takes 3-5 days. Patients were given written instructions to call the clinician within 3-5 days to discuss the histopathology results. The objective of the study was to perform an audit whether patients call the clinician to discuss their histopathology results after undergoing a colonoscopy, gastroscopy or both. A retrospective study was performed of patients attending for gastroscopy or colonoscopy at a single colorectal clinic at Cabrini Hospital, Melbourne, between 1 January and 31 December 2014. Age, pre-scope category and compliance with written instructions to callback were analysed. A total of 176 patients met the selection criteria, of whom 32.9% did not callback to discuss their histopathology results. Age and pre-scope category were independent predictors for patients to callback after endoscopy. The mean age of the patients who called back was higher (P < 0.01). Compared with patients who had a previous polyp or resection, patients in the pre-scope category of faecal occult blood testing/screening were more likely to callback (odds ratio: 4.37; 95% confidence interval: 1.17-16.31). Patients undergoing a colonoscopy for the purposes of screening and older patients were more likely to callback. Patients aged 62 years and younger were less likely to callback and should be targeted. Enhancements to the way information is presented to patients (e.g. video) should be considered for future studies. © 2017 Royal Australasian College of Surgeons.

  18. Splenic injury from colonoscopy: a review and management guidelines.

    PubMed

    Ghevariya, Vishal; Kevorkian, Noubar; Asarian, Armand; Anand, Sury; Krishnaiah, Mahesh

    2011-07-01

    Splenic injury is an uncommon complication of colonoscopy. Less than 100 cases are reported in the English language literature. The exact mechanism of injury to the spleen during colonoscopy is unknown; various authors propose several risk factors and possible mechanisms. Splenic injury can be graded or classified according to the extent of laceration and the severity of the resultant hematoma. The management options range from observation to emergency splenectomy. Computed tomography scan is the most important imaging modality to diagnose splenic injury. Early recognition and appropriate management is of paramount importance in the management of this condition. A high index of suspicion in a patient with persistent abdominal pain after colonoscopy is key especially when a perforated viscous is ruled out. This article outlines the clinical presentation of splenic injury after colonoscopy and delineates a management algorithm.

  19. Rescreening of persons with a negative colonoscopy result: results from a microsimulation model.

    PubMed

    Knudsen, Amy B; Hur, Chin; Gazelle, G Scott; Schrag, Deborah; McFarland, Elizabeth G; Kuntz, Karen M

    2012-11-06

    Persons with a negative result on screening colonoscopy are recommended to repeat the procedure in 10 years. To assess the effectiveness and costs of colonoscopy versus other rescreening strategies after an initial negative colonoscopy result. Microsimulation model. Literature and data from the Surveillance, Epidemiology, and End Results program. Persons aged 50 years who had no adenomas or cancer detected on screening colonoscopy. Lifetime. Societal. No further screening or rescreening starting at age 60 years with colonoscopy every 10 years, annual highly sensitive guaiac fecal occult blood testing (HSFOBT), annual fecal immunochemical testing (FIT), or computed tomographic colonography (CTC) every 5 years. Lifetime cases of colorectal cancer, life expectancy, and lifetime costs per 1000 persons, assuming either perfect or imperfect adherence. Rescreening with any method substantially reduced the risk for colorectal cancer compared with no further screening (range, 7.7 to 12.6 lifetime cases per 1000 persons [perfect adherence] and 17.7 to 20.9 lifetime cases per 1000 persons [imperfect adherence] vs. 31.3 lifetime cases per 1000 persons with no further screening). In both adherence scenarios, the differences in life-years across rescreening strategies were small (range, 30 893 to 30 902 life-years per 1000 persons [perfect adherence] vs. 30 865 to 30 869 life-years per 1000 persons [imperfect adherence]). Rescreening with HSFOBT, FIT, or CTC had fewer complications and was less costly than continuing colonoscopy. Results were sensitive to test-specific adherence rates. Data on adherence to rescreening were limited. Compared with the currently recommended strategy of continuing colonoscopy every 10 years after an initial negative examination, rescreening at age 60 years with annual HSFOBT, annual FIT, or CTC every 5 years provides approximately the same benefit in life-years with fewer complications at a lower cost. Therefore, it is reasonable to use other methods to rescreen persons with negative colonoscopy results. National Cancer Institute.

  20. Cost analysis of a patient navigation system to increase screening colonoscopy adherence among urban minorities.

    PubMed

    Jandorf, Lina; Stossel, Lauren M; Cooperman, Julia L; Graff Zivin, Joshua; Ladabaum, Uri; Hall, Diana; Thélémaque, Linda D; Redd, William; Itzkowitz, Steven H

    2013-02-01

    Patient navigation (PN) is being used increasingly to help patients complete screening colonoscopy (SC) to prevent colorectal cancer. At their large, urban academic medical center with an open-access endoscopy system, the authors previously demonstrated that PN programs produced a colonoscopy completion rate of 78.5% in a cohort of 503 patients (predominantly African Americans and Latinos with public health insurance). Very little is known about the direct costs of implementing PN programs. The objective of the current study was to perform a detailed cost analysis of PN programs at the authors' institution from an institutional perspective. In 2 randomized controlled trials, average-risk patients who were referred for SC by primary care providers were recruited for PN between May 2008 and May 2010. Patients were randomized to 1 of 4 PN groups. The cost of PN and net income to the institution were determined in a cost analysis. Among 395 patients who completed colonoscopy, 53.4% underwent SC alone, 30.1% underwent colonoscopy with biopsy, and 16.5% underwent snare polypectomy. Accounting for the average contribution margins of each procedure type, the total revenue was $95,266.00. The total cost of PN was $14,027.30. Net income was $81,238.70. In a model sample of 1000 patients, net incomes for the institutional completion rate (approximately 80%), the historic PN program (approximately 65%), and the national average (approximately 50%) were compared. The current PN program generated additional net incomes of $35,035.50 and $44,956.00, respectively. PN among minority patients with mostly public health insurance generated additional income to the institution, mainly because of increased colonoscopy completion rates. Copyright © 2012 American Cancer Society.

  1. Validation of the second-generation Olympus colonoscopy simulator for skills assessment.

    PubMed

    Haycock, A V; Bassett, P; Bladen, J; Thomas-Gibson, S

    2009-11-01

    Simulators have potential value in providing objective evidence of technical skill for procedures within medicine. The aim of this study was to determine face and construct validity for the Olympus colonoscopy simulator and to establish which assessment measures map to clinical benchmarks of expertise. Thirty-four participants were recruited: 10 novices with no prior colonoscopy experience, 13 intermediate (trainee) endoscopists with fewer than 1000 previous colonoscopies, and 11 experienced endoscopists with more than 1000 previous colonoscopies. All participants completed three standardized cases on the simulator and experts gave feedback regarding the realism of the simulator. Forty metrics recorded automatically by the simulator were analyzed for their ability to distinguish between the groups. The simulator discriminated participants by experience level for 22 different parameters. Completion rates were lower for novices than for trainees and experts (37 % vs. 79 % and 88 % respectively, P < 0.001) and both novices and trainees took significantly longer to reach all major landmarks than the experts. Several technical aspects of competency were discriminatory; pushing with an embedded tip ( P = 0.03), correct use of the variable stiffness function ( P = 0.004), number of sigmoid N-loops ( P = 0.02); size of sigmoid N-loops ( P = 0.01), and time to remove alpha loops ( P = 0.004). Out of 10, experts rated the realism of movement at 6.4, force feedback at 6.6, looping at 6.6, and loop resolution at 6.8. The Olympus colonoscopy simulator has good face validity and excellent construct validity. It provides an objective assessment of colonoscopic skill on multiple measures and benchmarks have been set to allow its use as both a formative and a summative assessment tool. Georg Thieme Verlag KG Stuttgart. New York.

  2. A novel summary report of colonoscopy: timeline visualization providing meaningful colonoscopy video information.

    PubMed

    Cho, Minwoo; Kim, Jee Hyun; Kong, Hyoun Joong; Hong, Kyoung Sup; Kim, Sungwan

    2018-05-01

    The colonoscopy adenoma detection rate depends largely on physician experience and skill, and overlooked colorectal adenomas could develop into cancer. This study assessed a system that detects polyps and summarizes meaningful information from colonoscopy videos. One hundred thirteen consecutive patients had colonoscopy videos prospectively recorded at the Seoul National University Hospital. Informative video frames were extracted using a MATLAB support vector machine (SVM) model and classified as bleeding, polypectomy, tool, residue, thin wrinkle, folded wrinkle, or common. Thin wrinkle, folded wrinkle, and common frames were reanalyzed using SVM for polyp detection. The SVM model was applied hierarchically for effective classification and optimization of the SVM. The mean classification accuracy according to type was over 93%; sensitivity was over 87%. The mean sensitivity for polyp detection was 82.1%, and the positive predicted value (PPV) was 39.3%. Polyps detected using the system were larger (6.3 ± 6.4 vs. 4.9 ± 2.5 mm; P = 0.003) with a more pedunculated morphology (Yamada type III, 10.2 vs. 0%; P < 0.001; Yamada type IV, 2.8 vs. 0%; P < 0.001) than polyps missed by the system. There were no statistically significant differences in polyp distribution or histology between the groups. Informative frames and suspected polyps were presented on a timeline. This summary was evaluated using the system usability scale questionnaire; 89.3% of participants expressed positive opinions. We developed and verified a system to extract meaningful information from colonoscopy videos. Although further improvement and validation of the system is needed, the proposed system is useful for physicians and patients.

  3. Educational strategies for colonoscopy bowel prep overcome barriers against split-dosing: A randomized controlled trial

    PubMed Central

    Andrealli, Alida; Paggi, Silvia; Amato, Arnaldo; Rondonotti, Emanuele; Imperiali, Gianni; Lenoci, Nicoletta; Mandelli, Giovanna; Terreni, Natalia; Spinzi, Giancarlo; Radaelli, Franco

    2018-01-01

    Background A split-dose (SD) regimen is crucial for colonoscopy quality. Compliance with SD for early morning colonoscopy is generally poor. The present study evaluated whether pre-colonoscopy counselling, in addition to a dedicated leaflet, might increase SD uptake. Methods Consecutive 50–69-year-old patients undergoing screening colonoscopy before 10 a.m. were randomized to either receive written information only on bowel preparation (Written Group, WG) or written and oral instructions (Written and Oral Group, WaOG). The leaflet strongly encouraged SD adoption. The primary endpoint was the number of patients adopting SD in each group. The secondary endpoints were predictors of SD uptake, compliance with preparation schemes and cleansing adequacy. Results A total of 286 patients (143 WG, 143 WaOG) were enrolled (mean age 59.6 ± 6.1 years, men 49.3%). SD was adopted by 114 and 125 patients in the WG and WaOG, respectively (79.7% versus 87.4%, p = 0.079). No significant differences were observed for the proportion of patients with full compliance with preparation scheme (97.9% versus 97.2%, p = 0.99) and of procedures with adequate bowel cleansing (95.6% versus 95.1%, p = 0.77). At multivariate analysis, a > 1 h travel time to the endoscopy service was inversely correlated with SD uptake (odds ratio (OR) 0.30, 95% confidence interval (CI) 0.09–0.98). Conclusions Our leaflet guaranteed satisfactory uptake of SD and excellent adherence to the preparation scheme for early morning colonoscopy. Its use might marginalize the need for additional oral instructions, particularly in open-access settings. PMID:29511558

  4. The Effect of Colonoscopy Reimbursement Reductions on Gastroenterologist Practice Behavior.

    PubMed

    McNeill, Matthew B; Chang, Shannon; Sahebjam, Farhad; Goodman, Adam J; Gross, Seth A; Sigal, Samuel H

    2016-06-01

    The purpose of this study was to assess the effect of decreased colonoscopy reimbursement on gastroenterologist practice behavior, including time to retirement and procedure volume. In 2015, the Centers for Medicare and Medicaid Services proposed reductions in colonoscopy reimbursements. With new initiatives for increased colorectal cancer screening, it is crucial to understand how reimbursement changes could affect these efforts. Randomly selected respondents from the American College of Gastroenterology membership database were surveyed on incremental changes in practice behavior if colonoscopy reimbursement were to decrease by 10, 20, 30, or 40 %. Data were analyzed using both Pearson's Chi-square and analysis of variance. Two thousand and nine gastroenterologists received the survey with a 16.3 % response rate. Procedure volume significantly decreased with degree of reimbursement reductions (p < 0.001). With a 10 % decrease, 72 % of respondents reported no change in the number of colonoscopies performed. With a 20 % decrease, 39 % would decrease their procedure volume, while 21 % of respondents would increase their procedure volume. With a 30 and 40 % decrease, procedure volume decreased by 48 and 50 %, respectively. In terms of retirement, current plans predict a cumulative retirement rate of 29.4 % at 10 years. More than 42 % of respondents plan to retire after 2030. In the 2014-2023 retirement subgroup (N = 74 responses), there was a significant hastening of retirement year at 20 % (p = 0.016), 30 % (p < 0.001), and 40 % (p < 0.001) reimbursement reductions as compared to baseline responses. Decreasing colonoscopy reimbursements may have a significant effect on the effective gastroenterology work force.

  5. Efficacy of morning-only 4 liter sulfa free polyethylene glycol vs 2 liter polyethylene glycol with ascorbic acid for afternoon colonoscopy

    PubMed Central

    Rivas, John M; Perez, Alejandro; Hernandez, Marlow; Schneider, Alison; Castro, Fernando J

    2014-01-01

    AIM: To compare the bowel cleansing efficacy of same day ingestion of 4-L sulfa-free polyethylene glycol (4-L SF-PEG) vs 2-L polyethylene glycol solution with ascorbic acid (2-L PEG + Asc) in patients undergoing afternoon colonoscopy. METHODS: 206 patients (mean age 56.7 years, 61% male) undergoing outpatient screening or surveillance colonoscopies were prospectively randomized to receive either 4-L SF-PEG (n = 104) or 2-L PEG + Asc solution (n = 102). Colonoscopies were performed by two blinded endoscopists. Bowel preparation was graded using the Ottawa scale. Each participant completed a satisfaction and side effect survey. RESULTS: There was no difference in patient demographics amongst groups. 4-L SF-PEG resulted in better Ottawa scores compared to 2-L PEG + Asc, 4.2 vs 4.9 (P = 0.0186); left colon: 1.33 vs 1.57 respectively (P = 0.0224), right colon: 1.38 vs 1.63 respectively (P = 0.0097). No difference in Ottawa scores was found for the mid colon or amount of fluid. Patient satisfaction was similar for both arms but those assigned to 4-L SF-PEG reported less bloating: 23.1% vs 11.5% (P = 0.0235). Overall polyp detection, adenomatous polyp and advanced adenoma detection rates were similar between the two groups. CONCLUSION: Morning only 4-L SF-PEG provided superior cleansing with less bloating as compared to 2-L PEG + Asc bowel preparation for afternoon colonoscopy. Thus, future studies evaluating efficacy of morning only preparation for afternoon colonoscopy should use 4-L SF-PEG as the standard comparator. PMID:25132784

  6. Assessment of competency in endoscopy: establishing and validating generalizable competency benchmarks for colonoscopy.

    PubMed

    Sedlack, Robert E; Coyle, Walter J

    2016-03-01

    The Mayo Colonoscopy Skills Assessment Tool (MCSAT) has previously been used to describe learning curves and competency benchmarks for colonoscopy; however, these data were limited to a single training center. The newer Assessment of Competency in Endoscopy (ACE) tool is a refinement of the MCSAT tool put forth by the Training Committee of the American Society for Gastrointestinal Endoscopy, intended to include additional important quality metrics. The goal of this study is to validate the changes made by updating this tool and establish more generalizable and reliable learning curves and competency benchmarks for colonoscopy by examining a larger national cohort of trainees. In a prospective, multicenter trial, gastroenterology fellows at all stages of training had their core cognitive and motor skills in colonoscopy assessed by staff. Evaluations occurred at set intervals of every 50 procedures throughout the 2013 to 2014 academic year. Skills were graded by using the ACE tool, which uses a 4-point grading scale defining the continuum from novice to competent. Average learning curves for each skill were established at each interval in training and competency benchmarks for each skill were established using the contrasting groups method. Ninety-three gastroenterology fellows at 10 U.S. academic institutions had 1061 colonoscopies assessed by using the ACE tool. Average scores of 3.5 were found to be inclusive of all minimal competency thresholds identified for each core skill. Cecal intubation times of less than 15 minutes and independent cecal intubation rates of 90% were also identified as additional competency thresholds during analysis. The average fellow achieved all cognitive and motor skill endpoints by 250 procedures, with >90% surpassing these thresholds by 300 procedures. Nationally generalizable learning curves for colonoscopy skills in gastroenterology fellows are described. Average ACE scores of 3.5, cecal intubation rates of 90%, and intubation times less than 15 minutes are recommended as minimal competency criteria. On average, it takes 250 procedures to achieve competence in colonoscopy. The thresholds found in this multicenter cohort by using the ACE tool are nearly identical to the previously established MCSAT benchmarks and are consistent with recent gastroenterology training recommendations but far higher than current training requirements in other specialties. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. Predictors of poor adherence of U.S. gastroenterologists with colonoscopy screening and surveillance guidelines

    PubMed Central

    Iskandar, Heba; Yan, Yan; Elwing, Jill; Early, Dayna; Colditz, Graham A.; Wang, Jean S.

    2014-01-01

    Background The U.S. Multi-Society Task Force on Colorectal Cancer published guidelines for colonoscopy screening and surveillance in 2008 and affirmed them in 2012. Characteristics associated with guideline adherence among U.S. gastroenterologists have not been assessed. Aims Assess awareness and adherence of U.S. gastroenterologists with national guidelines for colonoscopy screening and surveillance and predictors of adherence to guidelines. Methods A web-based survey was administered to gastroenterologists in various practice settings across the United States. Results A total of 306 gastroenterologists completed the survey; 86% reported awareness of the guidelines. Low-volume colonoscopists (<20 /month) were less likely to be aware of the guidelines (OR 0.26, p=0.03) compared to high-volume colonoscopists (>100/month). Those completing training before 1990 were less likely to report following guidelines (OR 0.37, p=0.01). Adherence with guidelines was then assessed via clinical scenarios. Compared to physicians finishing training in 1991-2010, less adherence was seen in those finishing before 1990 (OR 0.75, p<0.001) or currently in training (OR 0.72, p=0.004). Compared to the Western U.S., less adherence was seen in the Midwest (OR 0.69, p=0.001), Northeast (OR 0.63, p<0.001), and South (OR 0.59, p<0.001). Lower adherence was seen among non-academic physicians (OR 0.72, p=0.001) and low-volume colonoscopists (OR 0.52, p<0.001). Conclusions There is poor adherence with colonoscopy screening and surveillance guidelines among U.S. gastroenterologists. Poor adherence was associated with being in training or finishing training before 1990, practicing in the South, non-academic settings, and low colonoscopy volume. These findings can target interventions for quality improvement in colorectal cancer screening and surveillance. PMID:25366146

  8. Predictors of Poor Adherence of US Gastroenterologists with Colonoscopy Screening and Surveillance Guidelines.

    PubMed

    Iskandar, Heba; Yan, Yan; Elwing, Jill; Early, Dayna; Colditz, Graham A; Wang, Jean S

    2015-04-01

    The US Multi-Society Task Force on Colorectal Cancer published guidelines for colonoscopy screening and surveillance in 2008 and affirmed them in 2012. Characteristics associated with guideline adherence among US gastroenterologists have not been assessed. Assess awareness and adherence of US gastroenterologists with national guidelines for colonoscopy screening and surveillance and predictors of adherence to guidelines. A Web-based survey was administered to gastroenterologists in various practice settings across the USA. A total of 306 gastroenterologists completed the survey; 86 % reported awareness of the guidelines. Low-volume colonoscopists (<20/month) were less likely to be aware of the guidelines (OR 0.26, p = 0.03) compared to high-volume colonoscopists (>100/month). Those completing training before 1990 were less likely to report following guidelines (OR 0.37, p = 0.01). Adherence with guidelines was then assessed via clinical scenarios. Compared to physicians finishing training in 1991-2010, less adherence was seen in those finishing before 1990 (OR 0.75, p < 0.001) or currently in training (OR 0.72, p = 0.004). Compared to the Western USA, less adherence was seen in the Midwest (OR 0.69, p = 0.001), Northeast (OR 0.63, p < 0.001), and South (OR 0.59, p < 0.001). Lower adherence was seen among non-academic physicians (OR 0.72, p = 0.001) and low-volume colonoscopists (OR 0.52, p < 0.001). There is poor adherence with colonoscopy screening and surveillance guidelines among US gastroenterologists. Poor adherence was associated with being in training or finishing training before 1990, practicing in the South, non-academic settings, and low colonoscopy volume. These findings can target interventions for quality improvement in colorectal cancer screening and surveillance.

  9. Outcome Analyses of 15,189 Screenings Via Colonoscopy.

    PubMed

    Liu, Lan; Gao, Hongwei; Yu, Weihua; Zhang, Shanyan; Guo, Jianqiang; Zhu, Kongxi

    2017-10-01

    This study investigated the detection rates of common colorectal diseases during colonoscopy procedures to provide reference for clinical diagnoses in China. A total of 15,189 participants, who underwent total colonoscopy, were studied. We analyzed the detection rates of common colorectal diseases in different sex, age, and decade groups. The most common indication for colonoscopy is abdominal pain followed by change in bowel habits. Among the 15,189 participants, 5658 cases (37.25%) were normal. The most common positive finding was colorectal polyp (27.32%) followed by nonspecific colitis (12.06%), colorectal cancer (CRC) (7.71%), and ulcerative colitis (4.64%). The frequencies of polyp (31.56% vs. 21.99%; P=0.000) and CRC (8.28% vs. 7.00%; P=0.004) were higher in males than in females. By contrast, ischemic colitis (0.08% vs. 0.31%; P=0.001) and melanosis coli (1.15% vs. 1.87%; P=0.000) were more seen in females than in males. In addition, the detection rates for CRC (2.42% vs. 7.18% vs. 16.67%; P=0.000), colorectal polyp (17.65% vs. 32.27% vs. 34.73%; P=0.000), ischemic colitis (0.09% vs. 0.19% vs. 0.32%; P=0.033), and melanosis coli (0.71% vs. 1.09% vs. 3.21%; P=0.000) increased with age. The frequent positive findings were colorectal polyp, nonspecific colitis, and CRC. Patients showing alarming symptoms definitely require colonoscopy. The detection rates for colorectal polyp and melanosis coli were significantly higher in the later decade, so we should focus on these deseases.

  10. A randomized, controlled, double-blind trial of the adjunct use of Clebopride in polyethylene glycol electrolyte (PEG) solution for colonoscopy preparation.

    PubMed

    Abdullah, Murdani; Rani, A Aziz; Fauzi, Achmad; Syam, Ari Fahrial; Makmun, Dadang; Simadibrata, Marcellus; Manan, Chudahman; Harjodisastro, Daldiyono

    2010-01-01

    To study the benefit of Clebopride as an adjuvant in polyethylene glycol electrolyte (PEG) solution for colonoscopy preparation. Eighty one adult patients who underwent colonoscopy examination were recruited in this randomized double blind controlled study. First group received PEG and placebo, whereas second group received PEG and Clebopride. Two litres of PEG was taken at night before colonoscopy. The acceptability and tolerability of bowel preparation were assessed through interview method. The efficacy of bowel preparation was assessed using Aronchick's Criteria. In terms of acceptability, 64 patients (31 patients from placebo group vs 33 patients from Clebopride group) were able to drink two litres of PEG solution. Sixty patients (29 patients from placebo group and 31 patients from Clebopride group) were willing to accept PEG solution for their next bowel preparation. On the term of tolerability, nausea, abdominal distension, and borborygmus were more frequent in the placebo group (34.2% vs 27.9%; 44.7% vs 32.6%; 26.3% vs 4.6% respectively). However, only the difference at the incidence of borborygmus that was statistically significant (p<0.05). On the terms of efficacy, both groups showed a comparable bowel preparation quality with 88.4% of bowel preparation in Clebopride group and 81.6% of bowel preparation in placebo group were optimal (p = 0.585). The adjunct use of Clebopride in PEG solution for colonoscopy preparations tends to increase the acceptability, tolerability, and efficacy. The presence of borborygmus was significantly lower in the Clebopride group.

  11. Family history of gastric cancer is associated with the risk of colorectal neoplasia in Korean population.

    PubMed

    Jung, Yoon Suk; Kim, Nam Hee; Yang, Hyo-Joon; Park, Soo-Kyung; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il

    2017-10-01

    Family history of cancers at different sites except for colorectum has not been evaluated as a risk factor for colorectal neoplasia (CRN). To investigate CRN risk according to family history of cancers at 12 different sites, including stomach and colorectum. A cross-sectional study was performed on 139,497 asymptomatic Koreans who underwent colonoscopy as part of a health check-up. The mean age of the study population was 41.6 and the prevalence of CRN was 16.3%. Multivariate analyses revealed that family histories of CRC (adjusted odds ratio; confidence interval, 1.26; 1.17-1.35) and gastric cancer (1.07; 1.01-1.13) were independent risk factors for CRN. Notably, the risk of CRN increased even more for participants with family histories of both CRC and gastric cancer (1.38; 1.12-1.70). Family history of CRC was associated with risk of CRN in participants aged both <50 and ≥50 years, whereas family history of gastric cancer was associated with risk of CRN in participants aged <50 years (1.22; 1.14-1.30), but not in participants aged ≥50 years (1.08; 0.99-1.18). Family history of gastric cancer was an independent risk factor for CRN, especially in those aged <50years. Persons with family histories of gastric cancer and CRC, especially those with family histories of both, may need to begin colonoscopy earlier. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  12. Comparison of fecal occult blood tests for colorectal cancer screening in an Alaska Native population with high prevalence of Helicobacter pylori infection, 2008-2012.

    PubMed

    Redwood, Diana; Provost, Ellen; Asay, Elvin; Roberts, Diana; Haverkamp, Donald; Perdue, David; Bruce, Michael G; Sacco, Frank; Espey, David

    2014-04-10

    Alaska Native colorectal cancer (CRC) incidence and mortality rates are the highest of any ethnic/racial group in the United States. CRC screening using guaiac-based fecal occult blood tests (gFOBT) are not recommended for Alaska Native people because of false-positive results associated with a high prevalence of Helicobacter pylori-associated hemorrhagic gastritis. This study evaluated whether the newer immunochemical FOBT (iFOBT) resulted in a lower false-positive rate and higher specificity for detecting advanced colorectal neoplasia than gFOBT in a population with elevated prevalence of H. pylori infection. We used a population-based sample of 304 asymptomatic Alaska Native adults aged 40 years or older undergoing screening or surveillance colonoscopy (April 2008-January 2012). Specificity differed significantly (P < .001) between gFOBT (76%; 95% CI, 71%-81%) and iFOBT (92%; 95% CI, 89%-96%). Among H. pylori-positive participants (54%), specificity of iFOBT was even higher (93% vs 69%). Overall, sensitivity did not differ significantly (P = .73) between gFOBT (29%) and iFOBT (36%). Positive predictive value was 11% for gFOBT and 32% for iFOBT. The iFOBT had a significantly higher specificity than gFOBT, especially in participants with current H. pylori infection. The iFOBT represents a potential strategy for expanding CRC screening among Alaska Native and other populations with elevated prevalence of H. pylori, especially where access to screening endoscopy is limited.

  13. Affordable Care Act Provision Lowered Out-Of-Pocket Cost And Increased Colonoscopy Rates Among Men In Medicare.

    PubMed

    Hamman, Mary K; Kapinos, Kandice A

    2015-12-01

    Colorectal cancer screening is one of the few cancer screenings with an "A" rating from the US Preventive Services Task Force, meaning that the procedure confers a substantial health benefit. However, 40 percent of people who should receive colorectal cancer screenings do not receive them. Colonoscopies are the most thorough method of screening because they allow physicians to view the entire length of the colon and remove polyps as needed. Billing methods that distinguish between screening and therapeutic procedures have kept expected colonoscopy costs high. However, the Affordable Care Act partially closed the so-called colonoscopy loophole and reduced expected out-of-pocket expenses for all Medicare beneficiaries. Using data from the Behavioral Risk Factor Surveillance System, we found that annual colonoscopy rates among men ages 66-75 increased significantly (by 4.0 percentage points) after the Affordable Care Act policy change, and we found some evidence of even larger increases among socioeconomically disadvantaged men. We found no significant increases among women, a result that may be explained by health behavior and other factors and that requires further study. Our research indicates that cost may be an important barrier to colorectal cancer screening, at least among men, and that making further policy changes to close remaining loopholes may improve screening rates. Project HOPE—The People-to-People Health Foundation, Inc.

  14. Importance of the Time Interval between Bowel Preparation and Colonoscopy in Determining the Quality of Bowel Preparation for Full-Dose Polyethylene Glycol Preparation

    PubMed Central

    Kim, Tae Kyung; Kim, Hyung Wook; Kim, Su Jin; Ha, Jong Kun; Jang, Hyung Ha; Hong, Young Mi; Park, Su Bum; Choi, Cheol Woong; Kang, Dae Hwan

    2014-01-01

    Background/Aims The quality of bowel preparation (QBP) is the important factor in performing a successful colonoscopy. Several factors influencing QBP have been reported; however, some factors, such as the optimal preparation-to-colonoscopy time interval, remain controversial. This study aimed to determine the factors influencing QBP and the optimal time interval for full-dose polyethylene glycol (PEG) preparation. Methods A total of 165 patients who underwent colonoscopy from June 2012 to August 2012 were prospectively evaluated. The QBP was assessed using the Ottawa Bowel Preparation Scale (Ottawa) score according to several factors influencing the QBP were analyzed. Results Colonoscopies with a time interval of 5 to 6 hours had the best Ottawa score in all parts of the colon. Patients with time intervals of 6 hours or less had the better QBP than those with time intervals of more than 6 hours (p=0.046). In the multivariate analysis, the time interval (odds ratio, 1.897; 95% confidence interval, 1.006 to 3.577; p=0.048) was the only significant contributor to a satisfactory bowel preparation. Conclusions The optimal time was 5 to 6 hours for the full-dose PEG method, and the time interval was the only significant contributor to a satisfactory bowel preparation. PMID:25368750

  15. [Reasearch progress in health economic evaluation of colorectal cancer screening in China].

    PubMed

    Huang, Huiyao; Shi, Jufang; Dai, Min

    2015-08-01

    Burden of colorectal cancer is rising in China. More attention and financial input have been paid to it by central government that colorectal cancer screening program has been carried out recently in many areas in China. Diversity of screening strategies and limited health resources render selecting the best strategy in a population-wide program a challenging task that economy was also required to be considered except safety and efficacy. To provide a reference for the subsequent further economic evaluation, here we reviewed the evidence available on the economic evaluation of colorectal cancer screening in China. Meanwhile, information related to screening strategies, participation and mid-term efficacy of screening, information and results on economic evaluation were extracted and summarized. Three of the four studies finally included evaluated strategies combining immunochemical fecel occult blood test (iFOBT) with high-risk factor questionnaire as initial screening, colonoscopy as diagnostic screening. There was a consensus regarding the efficacy and effectiveness of screening compared to no screening. Whereas the lack and poor comparability between studies, multi-perspective and multi-phase economic evaluation of colorectal cancer screening is needed, relying on current population-based screening program to conduct a comprehensive cost accounting.

  16. Colonoscopy can miss diverticula of the left colon identified by barium enema

    PubMed Central

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-01-01

    AIM: To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. METHODS: A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (< 70 or ≥ 70 years), sex, and colon location. The number of diverticula was counted, and the detection ratio was calculated. RESULTS: Colonic diverticula were observed in 46 patients with barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P < 0.01). CONCLUSION: Compared with barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon. PMID:23613630

  17. A randomized controlled trial of an educational video to improve quality of bowel preparation for colonoscopy.

    PubMed

    Park, Jin-Seok; Kim, Min Su; Kim, HyungKil; Kim, Shin Il; Shin, Chun Ho; Lee, Hyun Jung; Lee, Won Seop; Moon, Soyoung

    2016-06-17

    High-quality bowel preparation is necessary for colonoscopy. A few studies have been conducted to investigate improvement in bowel preparation quality through patient education. However, the effect of patient education on bowel preparation has not been well studied. A randomized and prospective study was conducted. All patients received regular instruction for bowel preparation during a pre-colonoscopy visit. Those scheduled for colonoscopy were randomly assigned to view an educational video instruction (video group) on the day before the colonoscopy, or to a non-video (control) group. Qualities of bowel preparation using the Ottawa Bowel Preparation Quality scale (Ottawa score) were compared between the video and non-video groups. In addition, factors associated with poor bowel preparation were investigated. A total of 502 patients were randomized, 250 to the video group and 252 to the non-video group. The video group exhibited better bowel preparation (mean Ottawa total score: 3.03 ± 1.9) than the non-video group (4.21 ± 1.9; P < 0.001) and had good bowel preparation for colonoscopy (total Ottawa score <6: 91.6 % vs. 78.5 %; P < 0.001). Multivariate analysis revealed that males (odds ratio [OR] = 1.95, P = 0.029), diabetes mellitus patients (OR = 2.79, P = 0.021), and non-use of visual aids (OR = 3.09, P < 0.001) were associated with poor bowel preparation. In the comparison of the colonoscopic outcomes between groups, the polyp detection rate was not significantly different between video group and non-video group (48/250, 19.2 % vs. 48/252, 19.0 %; P = 0.963), but insertion time was significantly short in video group (5.5 ± 3.2 min) than non-video group (6.1 ± 3.7 min; P = 0.043). The addition of an educational video could improve the quality of bowel preparation in comparison with standard preparation method. Clinical Research Information Service KCT0001836 . The date of registration: March, 08(th), 2016, Retrospectively registered.

  18. Individualized cost-effectiveness analysis of patient-centered care: a case series of hospitalized patient preferences departing from practice-based guidelines.

    PubMed

    Padula, William V; Millis, M Andrew; Worku, Aelaf D; Pronovost, Peter J; Bridges, John F P; Meltzer, David O

    2017-03-01

    To develop cases of preference-sensitive care and analyze the individualized cost-effectiveness of respecting patient preference compared to guidelines. Four cases were analyzed comparing patient preference to guidelines: (a) high-risk cancer patient preferring to forgo colonoscopy; (b) decubitus patient preferring to forgo air-fluidized bed use; (c) anemic patient preferring to forgo transfusion; (d) end-of-life patient requesting all resuscitative measures. Decision trees were modeled to analyze cost-effectiveness of alternative treatments that respect preference compared to guidelines in USD per quality-adjusted life year (QALY) at a $100,000/QALY willingness-to-pay threshold from patient, provider and societal perspectives. Forgoing colonoscopy dominates colonoscopy from patient, provider, and societal perspectives. Forgoing transfusion and air-fluidized bed are cost-effective from all three perspectives. Palliative care is cost-effective from provider and societal perspectives, but not from the patient perspective. Prioritizing incorporation of patient preferences within guidelines holds good value and should be prioritized when developing new guidelines.

  19. [Diagnosis accuracy of endoscopy (laparoscopy, hysteroscopy, fertiloscopy, cystoscopy, colonoscopy) in case of endometriosis: CNGOF-HAS Endometriosis Guidelines].

    PubMed

    Tardieu, A; Sire, F; Gauthier, T

    2018-03-01

    To provide clinical practice guidelines from the French college of obstetrics and gynecology (CNGOF) with the Haute Autorité de santé (HAS), based on the best evidence available, concerning the diagnosis accuracy of endoscopy (laparoscopy, hysteroscopy, fertiloscopy, cystoscopy, colonoscopy) in case of endometriosis. English and French review of literature about the diagnosis accuracy of endoscopy in case of endometriosis. Laparoscopy is useful in case of suspected endometriosis in patients with symptoms or infertility when appropriate preoperative assessment is negative (grade C). Biopsies during diagnosis laparoscopy are recommended in case of typical or atypical lesions to confirm endometriosis (grade B). It is not recommended to perform fertiloscopy in case of suspected endometriosis (grade C). Hysteroscopy could be performed in case of suspected endometriosis and infertility to eliminate endometrial polyp or septate uterus (grade C). Colonoscopy is not recommended in case of suspected deep posterior endometriosis (grade C). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  20. A Benchmark for Endoluminal Scene Segmentation of Colonoscopy Images.

    PubMed

    Vázquez, David; Bernal, Jorge; Sánchez, F Javier; Fernández-Esparrach, Gloria; López, Antonio M; Romero, Adriana; Drozdzal, Michal; Courville, Aaron

    2017-01-01

    Colorectal cancer (CRC) is the third cause of cancer death worldwide. Currently, the standard approach to reduce CRC-related mortality is to perform regular screening in search for polyps and colonoscopy is the screening tool of choice. The main limitations of this screening procedure are polyp miss rate and the inability to perform visual assessment of polyp malignancy. These drawbacks can be reduced by designing decision support systems (DSS) aiming to help clinicians in the different stages of the procedure by providing endoluminal scene segmentation. Thus, in this paper, we introduce an extended benchmark of colonoscopy image segmentation, with the hope of establishing a new strong benchmark for colonoscopy image analysis research. The proposed dataset consists of 4 relevant classes to inspect the endoluminal scene, targeting different clinical needs. Together with the dataset and taking advantage of advances in semantic segmentation literature, we provide new baselines by training standard fully convolutional networks (FCNs). We perform a comparative study to show that FCNs significantly outperform, without any further postprocessing, prior results in endoluminal scene segmentation, especially with respect to polyp segmentation and localization.

  1. The Value of Audio Devices in the Endoscopy Room (VADER) study: a randomised controlled trial.

    PubMed

    Ardalan, Zaid Sm; Vasudevan, Abhinav; Hew, Simon; Schulberg, Julien; Lontos, Steve

    2015-12-14

    To evaluate the effect of Star Wars music (SWM) compared with endoscopist-selected popular music (PM) on quality outcomes in colonoscopy. A single-centre, prospective, randomised controlled trial conducted in an endoscopy suite within a quaternary-centre gastroenterology unit, Melbourne, Australia. The primary outcome measures were procedure time, polyp detection rate (PDR) and adenoma detection rate (ADR). The secondary outcome measure was adenomas per colonoscopy (APC). 103 colonoscopies were analysed: 58 in the SWM group and 45 in the PM group. Bowel preparation was assessed as good or excellent in 57% of the SWM group compared with 69% of the PM group (P < 0.01). The PDR was significantly higher in the SWM group than in the PM group (60% v 35%; P = 0.006). Similarly, the ADR was significantly higher in the SWM group than in the PM group (48% v 27%; P = 0.01). The APC in the SWM group was 84% compared with 35% in the PM group (P = 0.01). SWM compared with PM improves key quality outcomes in colonoscopy, despite poorer bowel preparation.

  2. Colorectal Cancer: Cost-effectiveness of Colonoscopy versus CT Colonography Screening with Participation Rates and Costs.

    PubMed

    van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; Goede, S Lucas; Kuipers, Ernst J; Dekker, Evelien; Stoker, Jaap; van Ballegooijen, Marjolein

    2018-06-01

    Purpose To compare the cost-effectiveness of computed tomographic (CT) colonography and colonoscopy screening by using data on unit costs and participation rates from a randomized controlled screening trial in a dedicated screening setting. Materials and Methods Observed participation rates and screening costs from the Colonoscopy or Colonography for Screening, or COCOS, trial were used in a microsimulation model to estimate costs and quality-adjusted life-years (QALYs) gained with colonoscopy and CT colonography screening. For both tests, the authors determined optimal age range and screening interval combinations assuming a 100% participation rate. Assuming observed participation for these combinations, the cost-effectiveness of both tests was compared. Extracolonic findings were not included because long-term follow-up data are lacking. Results The participation rates for colonoscopy and CT colonography were 21.5% (1276 of 5924 invitees) and 33.6% (982 of 2920 invitees), respectively. Colonoscopy was more cost-effective in the screening strategies with one or two lifetime screenings, whereas CT colonography was more cost-effective in strategies with more lifetime screenings. CT colonography was the preferred test for willingness-to-pay-thresholds of €3200 per QALY gained and higher, which is lower than the Dutch willingness-to-pay threshold of €20 000. With equal participation, colonoscopy was the preferred test independent of willingness-to-pay thresholds. The findings were robust for most of the sensitivity analyses, except with regard to relative screening costs and subsequent participation. Conclusion Because of the higher participation rates, CT colonography screening for colorectal cancer is more cost-effective than colonoscopy screening. The implementation of CT colonography screening requires previous satisfactory resolution to the question as to how best to deal with extracolonic findings. © RSNA, 2018 Online supplemental material is available for this article.

  3. Association between diverticular disease and Ehlers-Danlos syndrome: a 13-year nationwide population-based cohort study.

    PubMed

    Leganger, Julie; Søborg, Marie-Louise Kulas; Mortensen, Laura Quitzau; Gregersen, Rasmus; Rosenberg, Jacob; Burcharth, Jakob

    2016-12-01

    The aim of this study was to examine occurrence and consequences of diverticular disease in patients with Ehlers-Danlos syndrome (EDS) compared with a matched cohort. This nationwide population-based cohort study was conducted using data from medical registers in Denmark from year 2000 to 2012. The EDS cohort was identified using the specific diagnosis code for EDS and was randomly matched in a ratio of 1:20 by sex and date of birth (±1 year) with persons from the Danish general population. The occurrence of diverticular disease and the clinical characteristics of the initial diverticular event were compared between the EDS cohort and the comparison cohort. The first admission with diverticulitis was identified, and severity of diverticulitis, treatment, colonoscopies, length of stay, and 30-day mortality were investigated. We identified 1336 patients with EDS and matched a control cohort of 26,720 patients. The occurrence of diverticular disease in the EDS cohort (2.0 %) and the comparison cohort (0.68 %) differed significantly (p < 0.001). At the first diverticular event, the majority of patients were women (85 % for EDS and 87 % for the comparison cohort). Mean age, localization, and type of contact did not differ significantly. Admission with diverticulitis (1.0 % for EDS and 0.34 % for the comparison cohort) differed significantly (p < 0.001). We found no significant difference in severity of diverticulitis, treatment, length of stay, or 30-day mortality between the EDS and the comparison cohorts. Patients with EDS had an increased occurrence of overall diverticular events and admissions with diverticulitis compared with the general population.

  4. Colonoscopy and Colorectal Cancer Screening in Adults with Intellectual and Developmental Disabilities: Review of a Series of Cases and Recommendations for Examination

    ERIC Educational Resources Information Center

    Fischer, Leonard S.; Becker, Andrew; Paraguya, Maria; Chukwu, Cecilia

    2012-01-01

    Adults with intellectual and developmental disabilities (IDD) frequently have comorbidities that might interfere with colonoscopy preparation and examination. In this article, the authors review their experience with colonoscopies performed from 2002 through 2010 on adults with IDD at a state institution to evaluate quality and safety of…

  5. Efficacy of prokinetic agents in improving bowel preparation for colonoscopy.

    PubMed

    Mishima, Yuko; Amano, Yuji; Okita, Koichi; Takahashi, Yoshiko; Moriyama, Nobuyuki; Ishimura, Norihisa; Furuta, Kenji; Ishihara, Shunji; Adachi, Kyoichi; Kinoshita, Yoshikazu

    2008-01-01

    Colonoscopy plays an important role in the diagnosis and treatment of gastrointestinal illness in both Western countries and Japan. However, preparative bowel cleansing for colonoscopy is frequently troublesome for elderly and/or constipated patients, since they must drink larger volumes of lavage solution for adequate cleansing. We investigated the use of prokinetic agents for improving the efficacy and tolerability of bowel cleansing prior to colonoscopy. 613 patients were divided into two groups according to oral lavage solution used (polyethylene glycol or magnesium citrate), and were further randomized to receive either vehicle (100 ml water) alone, vehicle with 5 mg mosapride citrate, or vehicle with 50 mg itopride hydrochloride 30 min before administration of lavage solution. Experimental parameters included bowel cleansing quality, times to first defecation and completion of bowel cleansing, and incidence of uncomfortable abdominal symptoms during colonoscopy preparation. Administration of mosapride citrate or itopride hydrochloride prior to oral lavage solution did not significantly improve bowel cleansing quality. However, statistically significantly fewer uncomfortable abdominal symptoms were found in patients who received mosapride citrate or itopride hydrochloride versus vehicle alone. Prokinetic agents effectively decreased the incidence of uncomfortable abdominal symptoms experienced during colonoscopy preparation. Copyright 2008 S. Karger AG, Basel.

  6. A Genetically Engineered Mouse Model of Sporadic Colorectal Cancer.

    PubMed

    Betzler, Alexander M; Kochall, Susan; Blickensdörfer, Linda; Garcia, Sebastian A; Thepkaysone, May-Linn; Nanduri, Lahiri K; Muders, Michael H; Weitz, Jürgen; Reissfelder, Christoph; Schölch, Sebastian

    2017-07-06

    Despite the advantages of easy applicability and cost-effectiveness, colorectal cancer mouse models based on tumor cell injection have severe limitations and do not accurately simulate tumor biology and tumor cell dissemination. Genetically engineered mouse models have been introduced to overcome these limitations; however, such models are technically demanding, especially in large organs such as the colon in which only a single tumor is desired. As a result, an immunocompetent, genetically engineered mouse model of colorectal cancer was developed which develops highly uniform tumors and can be used for tumor biology studies as well as therapeutic trials. Tumor development is initiated by surgical, segmental infection of the distal colon with adeno-cre virus in compound conditionally mutant mice. The tumors can be easily detected and monitored via colonoscopy. We here describe the surgical technique of segmental adeno-cre infection of the colon, the surveillance of the tumor via high-resolution colonoscopy and present the resulting colorectal tumors.

  7. Variation of adenoma prevalence by age, sex, race, and colon location in a large population: implications for screening and quality programs.

    PubMed

    Corley, Douglas A; Jensen, Christopher D; Marks, Amy R; Zhao, Wei K; de Boer, Jolanda; Levin, Theodore R; Doubeni, Chyke; Fireman, Bruce H; Quesenberry, Charles P

    2013-02-01

    Reliable community-based colorectal adenoma prevalence estimates are needed to inform colonoscopy quality standards and to estimate patient colorectal cancer risks; however, minimal data exist from populations with large numbers of diverse patients and examiners. We evaluated the prevalence of adenomas detected by sex, age, race/ethnicity, and colon location among 20,792 Kaiser Permanente Northern California members ≥50 years of age who received a screening colonoscopy examination (102 gastroenterologists, 2006-2008). Prevalence of detected adenomas increased more rapidly with age in the proximal colon (adjusted odds ratio [OR], 2.39; 95% confidence interval [CI], 2.05-2.80; 70-74 vs 50-54 years) than in the distal colon (OR, 1.89; 95% CI, 1.63-2.19). Prevalence was higher among men vs women at all ages (OR, 1.77; 95% CI, 1.66-1.89), increasing in men from 25% to 39% at ≥70 years and in women from 15% at 50-54 years to 26% (P < .001). Proximal adenoma prevalence was higher among blacks than whites (OR, 1.26; 95% CI, 1.04-1.54), although total prevalence was similar, including persons <60 years old (OR, 1.17; 95% CI, 0.91-1.50). Prevalence of detected adenomas increases substantially with age and is much higher in men; proximal adenomas are more common among blacks than whites, although the total prevalence and the prevalence for ages <60 years were similar by race. These demographic differences are such that current adenoma detection guidelines may not be valid, without adjustment, for comparing providers serving different populations. The variation in prevalence and location may also have implications for the effectiveness of screening methods in different demographic groups. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  8. Dual modality virtual colonoscopy workstation: design, implementation, and preliminary evaluation

    NASA Astrophysics Data System (ADS)

    Chen, Dongqing; Meissner, Michael

    2006-03-01

    The aim of this study is to develop a virtual colonoscopy (VC) workstation that supports both CT (computed tomography) and MR (magnetic resonance) imaging procedures. The workflow should be optimized and be able to take advantage of both image modalities. The technological break through is at the real-time volume rendering of spatial-intensity-inhomogeneous MR images to achieve high quality 3D endoluminal view. VC aims at visualizing CT or MR tomography images for detection of colonic polyp and lesion. It is also called as CT/MR colonography based on the imaging modality that is employed. The published results of large scale clinical trial demonstrated more than 90% of sensitivity on polyp detection for certain CT colonography (CTC) workstation. A drawback of the CT colonoscopy is the radiation exposure. MR colonography (MRC) is free from the X-ray radiation. It achieved almost 100% specificity for polyp detection in published trials. The better tissue contrast in MR image allows the accurate diagnosis of inflammatory bowel disease also, which is usually difficult in CTC. At present, most of the VC workstations are designed for CT examination. They are not able to display multi-sequence MR series concurrently in a single application. The automatic correlation between 2D and 3D view is not available due to the difficulty of 3D model building for MR images. This study aims at enhancing a commercial VC product that was successfully used for CTC to equally support dark-lumen protocol MR procedure also.

  9. Risk for colorectal cancer in ulcerative colitis: changes, causes and management strategies.

    PubMed

    Lakatos, Peter-Laszlo; Lakatos, Laszlo

    2008-07-07

    The risk of colorectal cancer for any patient with ulcerative colitis is known to be elevated, and is estimated to be 2% after 10 years, 8% after 20 years and 18% after 30 years of disease. Risk factors for cancer include extent and duration of ulcerative colitis, primary sclerosing cholangitis, a family history of sporadic colorectal cancer, severity of histologic bowel inflammation, and in some studies, young age at onset of colitis. In this review, the authors discuss recent epidemiological trends and causes for the observed changes. Population-based studies published within the past 5 years suggest that this risk has decreased over time, despite the low frequency of colectomies. The crude annual incidence rate of colorectal cancer in ulcerative colitis ranges from approximately 0.06% to 0.16% with a relative risk of 1.0-2.75. The exact mechanism for this change is unknown; it may partly be explained by the more widespread use of maintenance therapy and surveillance colonoscopy.

  10. Effect of music on level of anxiety in patients undergoing colonoscopy without sedation.

    PubMed

    Ko, Chia-Hui; Chen, Yi-Yu; Wu, Kuan-Ta; Wang, Shu-Chi; Yang, Jeng-Fu; Lin, Yu-Yin; Lin, Chia-I; Kuo, Hsiang-Ju; Dai, Chia-Yen; Hsieh, Meng-Hsuan

    2017-03-01

    Listening to music can be a noninvasive method for reducing the anxiety level without any adverse effects. The aim of this study was to explore whether music can reduce anxiety and to compare two different styles of music, informal classical music and light music, to ascertain the more effective style of music in reducing anxiety in patients undergoing colonoscopy without sedation. This study enrolled 138 patients who underwent colonoscopy without sedation during a general health examination from February 2009 to January 2015. The patients were randomly assigned to a group that did not listen to music, a group that listened to music by David Tolley, or a group that listened to music by Kevin Kern. The State-Trait Anxiety Inventory was used to evaluate the status of anxiety. A trend test for mild anxiety was performed on the patients in the three groups, and a significant trend was noted (p=0.017 for all patients; p=0.014 for analysis by sex). Multivariate analysis for mild anxiety on the patients in each group was also performed in this study, and music by Kevin Kern was found to have the lowest odds ratio (Odds ratio=0.34, p=0.045). Listening to music, especially music by Kevin Kern, reduced the level of anxiety in patients undergoing colonoscopy examination without sedation. Copyright © 2016. Published by Elsevier Taiwan LLC.

  11. A Risk Prediction Index for Advanced Colorectal Neoplasia at Screening Colonoscopy.

    PubMed

    Schroy, Paul C; Wong, John B; O'Brien, Michael J; Chen, Clara A; Griffith, John L

    2015-07-01

    Eliciting patient preferences within the context of shared decision making has been advocated for colorectal cancer screening. Risk stratification for advanced colorectal neoplasia (ACN) might facilitate more effective shared decision making when selecting an appropriate screening option. Our objective was to develop and validate a clinical index for estimating the probability of ACN at screening colonoscopy. We conducted a cross-sectional analysis of 3,543 asymptomatic, mostly average-risk patients 50-79 years of age undergoing screening colonoscopy at two urban safety net hospitals. Predictors of ACN were identified using multiple logistic regression. Model performance was internally validated using bootstrapping methods. The final index consisted of five independent predictors of risk (age, smoking, alcohol intake, height, and a combined sex/race/ethnicity variable). Smoking was the strongest predictor (net reclassification improvement (NRI), 8.4%) and height the weakest (NRI, 1.5%). Using a simplified weighted scoring system based on 0.5 increments of the adjusted odds ratio, the risk of ACN ranged from 3.2% (95% confidence interval (CI), 2.6-3.9) for the low-risk group (score ≤2) to 8.6% (95% CI, 7.4-9.7) for the intermediate/high-risk group (score 3-11). The model had moderate to good overall discrimination (C-statistic, 0.69; 95% CI, 0.66-0.72) and good calibration (P=0.73-0.93). A simple 5-item risk index based on readily available clinical data accurately stratifies average-risk patients into low- and intermediate/high-risk categories for ACN at screening colonoscopy. Uptake into clinical practice could facilitate more effective shared decision-making for CRC screening, particularly in situations where patient and provider test preferences differ.

  12. Meat consumption and colorectal cancer risk in Japan: The Takayama study.

    PubMed

    Wada, Keiko; Oba, Shino; Tsuji, Michiko; Tamura, Takashi; Konishi, Kie; Goto, Yuko; Mizuta, Fumi; Koda, Sachi; Hori, Akihiro; Tanabashi, Shinobu; Matsushita, Shogen; Tokimitsu, Naoki; Nagata, Chisato

    2017-05-01

    Compared with the abundant data from Western countries, evidence regarding meat consumption and colorectal cancer is limited in the Japanese population. We evaluated colorectal cancer risk in relation to meat consumption in a population-based prospective cohort study in Japan. Participants were 13 957 men and 16 374 women aged ≥35 years in September 1992. Meat intake, assessed with a validated food frequency questionnaire, was controlled for the total energy intake. The incidence of colorectal cancer was confirmed through regional population-based cancer registries and histological identification from colonoscopy in two main hospitals in the study area. From September 1992 to March 2008, 429 men and 343 women developed colorectal cancer. After adjustments for multiple confounders, a significantly increased relative risk of colorectal cancer was observed in the highest versus lowest quartile of the intake of total and red meat among men; the estimated hazard ratios were 1.36 (95% CI: 1.03, 1.79) for total meat (P for trend = 0.022), and 1.44 (95% CI: 1.10, 1.89) for red meat (P for trend = 0.009). A positive association between processed meat intake and colon cancer risk was also observed in men. There was no significant association between colorectal cancer and meat consumption in women. These results suggest that the intake of red and processed meat increases the risk of colorectal or colon cancer among Japanese men. Abstaining from excessive consumption of meat might be protective against developing colorectal cancer. © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  13. Prevalence of colorectal diseases in immunological fecal occult blood test (I-FOBT) positive patients in a tertiary care hospital in Bangladesh.

    PubMed

    Mollick, S H; Roy, P K; Bhuiyan, M R; Mia, A R; Alam, M S; Mollick, K A; Pervin, S; Hassan, M Q

    2014-10-01

    Bleeding lesion anywhere in the GI tract can cause positive reaction to Immunological Fecal Occult Blood Test (FOBT). Although any colonic lesion can cause occult lower GI bleeding, relative frequency of this lesion not known. Guaic based tests require prior preparation and dietary restriction and less sensitive and specific than IFOBT for detection of occult bleeding .IFOBT is specific for human hemoglobin and is more sensitive and specific for detection of occult bleeding from any colonic lesion. Aim of this study was to diagnose occult gastrointestinal bleeding with positive IFOBT and the prevalence of colorectal disease in IFOBT positive patients in a tertiary care hospital in Bangladesh. This was a prospective cross sectional study conducted in Department of gastroenterology in collaboration with clinical pathology, BSMMU, Dhaka during the period of January 2009 to December 2009. In this study 200 patients meeting the inclusion criteria were included. Detailed clinical history and physical findings were recorded; FOBT was done on single stool specimen. Positive occult bleeding was confirmed in 90 patients of whom 80 patients underwent colonoscopy. The mean age of study population was 36.73±13.64 (range 16 to 72) years. At colonoscopy lesion were identified in 46(57.50%) patients, of which colonic polyp in12 (15%), colorectal cancer in 11(13.7%), inflammatory bowel disease in 3(3.75%), hemorrhoids and anal fissure in 7(8.75%), tuberculosis in 5(6.25%), and proctitis in 1(1.25%) cases. A positive IFOBT is more sensitive and specific test than other FOBT for detection of occult lower GI bleeding of colonic origin. In this study colorectal diseases were detected in 57.50% of the IFOBT positive patients, so IOBT can be used as an important diagnostic tool for detection of occult lower GI bleeding.

  14. Iatrogenic pneumomediastinum and subcutaneous emphysema as a complication of colonoscopy with cold forceps biopsy.

    PubMed

    Loughlin, Michael T; Duncan, Timothy J

    2012-04-01

    A 58-year-old woman underwent outpatient colonoscopy with multiple cold forceps biopsy for evaluation of a presumptive diagnosis of ulcerative colitis. Six hours following the procedure, she developed subcutaneous crepitus and presented to the emergency department, where chest X-ray revealed pneumomediastinum and subcutaneous emphysema. Our case discusses this unusual complication of colonoscopy and its diagnosis and management.

  15. Cost-effectiveness of alternative colonoscopy surveillance strategies to mitigate metachronous colorectal cancer incidence.

    PubMed

    Erenay, Fatih Safa; Alagoz, Oguzhan; Banerjee, Ritesh; Said, Adnan; Cima, Robert R

    2016-08-15

    The incidence of metachronous colorectal cancer (MCRC) among colorectal cancer (CRC) survivors varies significantly, and the optimal colonoscopy surveillance practice for mitigating MCRC incidence is unknown. A cost-effectiveness analysis was used to compare the performances of the US Multi-Society Task Force guideline and all clinically reasonable colonoscopy surveillance strategies for 50- to 79-year-old posttreatment CRC patients with a computer simulation model. The US guideline [(1,3,5)] recommends the first colonoscopy 1 year after treatment, whereas the second and third colonoscopies are to be repeated at 3- and 5-year intervals. Some promising alternative cost-effective strategies were identified. In comparison with the US guideline, under various scenarios for a 20-year period, 1) reducing the surveillance interval of the guideline after the first colonoscopy by 1 year [(1,2,5)] would save up to 78 discounted life-years (LYs) and prevent 23 MCRCs per 1000 patients (incremental cost-effectiveness ratio [ICER] ≤ $23,270/LY), 2) reducing the intervals after the first and second negative colonoscopies by 1 year [(1,2,4)] would save/prevent up to 109 discounted LYs and 36 MCRCs (ICER ≤ $52,155/LY), and 3) reducing the surveillance intervals after the first and second negative colonoscopy by 1 and 2 years [(1,2,3)] would save/prevent up to 141 discounted LYs and 50 MCRCs (ICER ≤ $63,822/LY). These strategies would require up to 1100 additional colonoscopies per 1000 patients. Although the US guideline might not be cost-effective in comparison with a less intensive oncology guideline [(3,3,5); the ICER could be as high as $140,000/LY], the promising strategies would be cost-effective in comparison with such less intensive guidelines unless the cumulative MCRC incidence were very low. The US guideline might be improved by a slight increase in the surveillance intensity at the expense of moderately increased cost. More research is warranted to explore the benefits/harms of such practices. Cancer 2016;122:2560-70. © 2016 American Cancer Society. © 2016 American Cancer Society.

  16. Colon cancer screening

    MedlinePlus

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  17. Fluid tagging for CT colonography: effectiveness of a 2-hour iodinated oral preparation after incomplete optical colonoscopy.

    PubMed

    Chang, Kevin J; Rekhi, Satinder S; Anderson, Stephan W; Soto, Jorge A

    2011-01-01

    To evaluate the distal extent and attenuation of bowel opacification achieved after administration of a single low volume dose of oral contrast 2 hours before computed tomographic colonography (CTC) after incomplete optical colonoscopy. This retrospective study included 144 patients undergoing CTC after incomplete colonoscopy from April 2006 to July 2008 at 2 separate medical centers. Each patient received 20 to 30 mL of diatrizoate meglumine and diatrizoate sodium solution 2 hours before being scanned. The distalmost extent of opacification was: stomach/small bowel, n = 13; cecum, n = 2; ascending colon, n = 7; transverse colon, n = 19; descending colon, n = 14; sigmoid colon, n = 24; rectum, n = 65. The mean attenuation of each opacified segment was: cecum, 449 Hounsfield units (HU); ascending colon, 474 HU; transverse colon, 468 HU; descending colon, 421 HU; sigmoid colon, 391 HU; and rectum, 382 HU. In 103 (71.5%) patients, oral contrast reached the distal colon (descending colon, sigmoid colon, or rectum). The oral contrast did not reach the colon in only 13 (9.0%) patients. Oral administration of a small volume hyperosmolar oral contrast agent 2 hours before CTC results in satisfactory colonic opacification in the majority of patients. Adding same-day fluid tagging in incomplete colonoscopy patients presenting for completion CTC should result in adequate fluid opacification for most of the colon, especially proximal segments not visualized at the time of incomplete colonoscopy.

  18. Systematic review with meta-analysis: the incidence of advanced neoplasia after polypectomy in patients with and without low-risk adenomas.

    PubMed

    Hassan, C; Gimeno-García, A; Kalager, M; Spada, C; Zullo, A; Costamagna, G; Senore, C; Rex, D K; Quintero, E

    2014-05-01

    Patients with one to two tubular adenomas <1 cm in size without high-grade dysplasia (low-risk group) are considered at low risk for colorectal cancer. However, it is uncertain whether they have the same risk of subsequent advanced neoplasia as those with no neoplasia at baseline colonoscopy. To compare incidence of metachronous advanced neoplasia between patients in the low-risk adenoma group and those without neoplasia at index colonoscopy. Relevant publications were identified by MEDLINE/EMBASE and other databases for the period 1992-2013. Studies comparing the incidence of post-polypectomy advanced neoplasia (adenomas ≥10 mm/high-grade dysplasia/villous or cancer) between the low-risk group and patients without colorectal neoplasia at the first colonoscopy were included. Detection rates for advanced neoplasia at endoscopic surveillance were extracted. Study quality was ascertained according to Newcastle-Ottawa Scale. Forest plot was produced based on random-effect models. Inter-study heterogeneity was assessed using the I(2) statistic. Seven studies provided data on 11 387 patients. Mean surveillance periods ranged between 2 and 5 years. Altogether, 267 patients with post-polypectomy advanced neoplasia were detected in the two groups. The incidence of advanced neoplasia was 1.6% (119/7308) in those without neoplasia and 3.6% (148/4079) in those with low-risk adenoma, respectively, corresponding to a relative risk of 1.8 (95% CI: 1.3-2.6). Inter-study heterogeneity was only moderate (I(2) : 37%). No publication bias was present. Patients with low-risk adenomas at baseline had a higher risk of metachronous advanced neoplasia than the group with no adenomas at baseline, though the absolute risk was low in both groups. © 2014 John Wiley & Sons Ltd.

  19. Performance of a risk index for advanced proximal colorectal neoplasia among a racially/ethnically diverse patient population (risk index for advanced proximal neoplasia).

    PubMed

    Levitzky, Benjamin E; Brown, Colin C; Heeren, Timothy C; Schroy, Paul C

    2011-06-01

    Tailoring the use of screening colonoscopy based on the risk of advanced proximal neoplasia (APN) has been advocated as a strategy for reducing demand and optimizing effectiveness. A 7-point index based on age, sex, and distal findings at sigmoidoscopy has been proposed that stratifies individuals into low, intermediate, and high-risk categories. The aim of this cross-sectional analysis was to determine the validity of this index, which was originally derived and validated among mostly whites, for black and Hispanic patients. Data, including age, sex, colonoscopic findings, and pathology, were collected retrospectively from 1,481 white, 1,329 black, and 689 Hispanic asymptomatic, average-risk patients undergoing screening colonoscopy between 2000 and 2005. Cumulative scores ranging from 0 to 7 were derived for each subject and categorized as low, intermediate, or high risk. Rates of APN were assessed for each risk category after stratification by race/ethnicity. Index performance was assessed using the C-statistic and compared across the three racial groups. Rates of APN among patients categorized as low, intermediate, or high risk increased from 1.0 to 2.8 to 3.7% for whites, 1.0 to 2.2 to 4.2% for blacks, and 0.6 to 1.9 to 3.7% for Hispanics. The index performed similarly for all three groups, but showed limited ability to discriminate low from intermediate-risk patients, with C-statistic values of 0.62 for whites, 0.63 for blacks, and 0.68 for Hispanics. A risk index based on age, sex, and distal endoscopic findings has limited ability to discriminate low from intermediate-risk white, black, and Hispanic patients for APN.

  20. Clinical predictors and gender-wise variations in dyssynergic defecation disorders.

    PubMed

    Jain, Mayank; Baijal, Rajiv; Srinivas, Melpakkam; Venkataraman, Jayanthi

    2018-06-12

    There is insufficient data from India regarding clinical predictors of dyssynergic defecation. To identify demography, symptom, and colonoscopic parameters that can predict dyssynergic defecation (DD) among patients with chronic constipation (CC) and to compare the profile among male and female patients with DD. Data collected from three centers during June 2014 to May 2017 included age, gender, symptom duration, form and consistency of stools, digital examination, colonoscopy, and anorectal manometry (ARM). Patients were grouped based on ARM diagnosis: group I (normal study) and group II (DD). The two groups were compared for demography, symptom profile, and colonoscopy findings. Gender-wise subset analysis was done for those with the normal and abnormal ARM using chi-square and unpaired t tests. Of 236 patients with CC evaluated, 130 (55%) had normal ARM and 106 (45%) had DD. Male sex, straining during defecation, bleeding per rectum, and abnormal colonoscopic diagnosis were significantly more common in group II. While bleeding per rectum and absence of urge to defecate were more common in males (p < 0.02), straining, digital evacuation, and hard stools were commoner in females with DD. Straining during defecation, bleeding per rectum, and abnormal colonoscopy findings were more common in patients with DD. Symptoms of bleeding per rectum and absence of urge to defecate in men and straining during defecation in female patients were significantly associated with DD. Symptoms differ in males and females with DD.

Top