Sample records for color-coded duplex sonography

  1. Color-coded duplex sonography for diagnosis of testicular torsion.

    PubMed

    Zoeller, G; Ringert, R H

    1991-11-01

    By color-coded duplex sonography moving structures are visualized as red or blue colors within a normal gray-scale B-mode ultrasound image. Thus, blood flow even within small vessels can be visualized clearly. Color-coded duplex sonographic examination was performed in 11 patients who presented with scrotal pain. This method proved to be reliable to differentiate between testicular torsion and testicular inflammation. By clearly demonstrating a lack of intratesticular blood flow in testicular torsion, while avoiding flow in scrotal skin vessels being misinterpreted as intratesticular blood flow, this method significantly decreases the number of patients in whom surgical evaluation is necessary to exclude testicular torsion.

  2. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    PubMed

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  3. Evaluation of arteriovenous fistulas and pseudoaneurysms in renal allografts following percutaneous needle biopsy. Color-coded Doppler sonography versus duplex Doppler sonography.

    PubMed

    Hübsch, P J; Mostbeck, G; Barton, P P; Gritzmann, N; Fruehwald, F X; Schurawitzki, H; Kovarik, J

    1990-02-01

    One hundred one patients with renal allografts were studied by two independent observers using duplex Doppler sonography (DDS) and color-coded Doppler sonography (CCDS). In all patients, single or multiple percutaneous needle biopsies of the transplant had been performed 1 to 30 days before. In 6 patients CCDS following the biopsy demonstrated an area of combined red and blue color-coded blood flow within the renal parenchyma (n = 5) or within the sinus (n = 1); the Doppler waveform was abnormal in these areas with signals above and below the zero line indicating turbulent blood flow. Consecutive intraarterial digital subtraction angiography (DSA) revealed the presence of an arteriovenous fistula (n = 4) or of a pseudoaneurysm (n = 2). In one patient, gross hematuria with obstruction of the bladder occurred as a complication of a pseudoaneurysm within the renal sinus; the bleeding could not be stopped by embolization of the lesion and the kidney had to be removed. DDS demonstrated the lesion in only one of the six patients. Thus, CCDS is the method of choice for noninvasive detection of vascular lesions due to percutaneous biopsy.

  4. Learning vector quantization neural networks improve accuracy of transcranial color-coded duplex sonography in detection of middle cerebral artery spasm--preliminary report.

    PubMed

    Swiercz, Miroslaw; Kochanowicz, Jan; Weigele, John; Hurst, Robert; Liebeskind, David S; Mariak, Zenon; Melhem, Elias R; Krejza, Jaroslaw

    2008-01-01

    To determine the performance of an artificial neural network in transcranial color-coded duplex sonography (TCCS) diagnosis of middle cerebral artery (MCA) spasm. TCCS was prospectively acquired within 2 h prior to routine cerebral angiography in 100 consecutive patients (54M:46F, median age 50 years). Angiographic MCA vasospasm was classified as mild (<25% of vessel caliber reduction), moderate (25-50%), or severe (>50%). A Learning Vector Quantization neural network classified MCA spasm based on TCCS peak-systolic, mean, and end-diastolic velocity data. During a four-class discrimination task, accurate classification by the network ranged from 64.9% to 72.3%, depending on the number of neurons in the Kohonen layer. Accurate classification of vasospasm ranged from 79.6% to 87.6%, with an accuracy of 84.7% to 92.1% for the detection of moderate-to-severe vasospasm. An artificial neural network may increase the accuracy of TCCS in diagnosis of MCA spasm.

  5. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.

    PubMed

    Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw

    2009-03-01

    To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed <50%, and >50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

  6. Transcranial color-coded duplex sonography for evaluation of midline-shift after chronic-subdural hematoma evacuation (TEMASE): A prospective study.

    PubMed

    Cattalani, Andrea; Grasso, Vincenzo Maria; Vitali, Matteo; Gallesio, Ivan; Magrassi, Lorenzo; Barbanera, Andrea

    2017-11-01

    The incidence of chronic Subdural hematoma (cSDH) is increasing and its rate of recurrence varies from 5 to 33%. A postoperative brain midline-shift (MLS) on computed tomography (CT) equal or larger than 5mm is a risk factor for recurrence. Transcranial color-coded duplex sonography (TCCDS) is a noninvasive bedside reproducible technique useful to detect MLS. The aim of our study was to compare in patients affected by cSDH, the values of MLS obtained pre- and post-operatively by TCCDS and brain CT. 32 patients affected by cSDH entered the study between July 2016 and January 2017. MLS values obtained by TCCDS and brain CT were compared using Bland-Altman plot and linear regression analysis. Using the same techniques we also explored if the agreement between the two imaging modes was comparable in pre- and post-operative data pairs. 64 data pairs of MLS values obtained by TCCDS and CT were analysed. Bland-Altman diagrams did not show any systematic bias of the data and linear regression indicated a significant correlation between the two measures both before and after hematoma evacuation. In patients affected by cSDH, MLS values obtained before and after surgery by TCCDS are comparable to those obtained by CT; TCCDS might be considered an alternative to CT scan in the management of patients after cSDH evacuation. We suggest that close clinical bedside examination and TCCDS might be appropriate for the post-operative management of cSDH, reserving CT scan only to patients with overt clinical deterioration and/or increasing MLS. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.

    PubMed

    Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R

    2017-08-01

    Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P < .001) and midline shift ( r = 0.827; P < .001). The logistic regression analysis with transcranial duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.

  8. Narrowing of the middle cerebral artery: artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD.

    PubMed

    Swiercz, Miroslaw; Swiat, Maciej; Pawlak, Mikolaj; Weigele, John; Tarasewicz, Roman; Sobolewski, Andrzej; Hurst, Robert W; Mariak, Zenon D; Melhem, Elias R; Krejza, Jaroslaw

    2010-01-01

    The goal of the study was to compare performances of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of the middle cerebral artery (MCA) narrowing in the same population of patients using statistical and nonstatistical intelligent models for data analysis. We prospectively collected data from 179 consecutive routine digital subtraction angiography (DSA) procedures performed in 111 patients (mean age 54.17+/-14.4 years; 59 women, 52 men) who underwent TCD and TCCS examinations simultaneously. Each patient was examined independently using both ultrasound techniques, 267 M1 segments of MCA were assessed and narrowings were classified as < or =50% and >50% lumen reduction. Diagnostic performance was estimated by two statistical and two artificial neural networks (ANN) classification methods. Separate models were constructed for the TCD and TCCS sonographic data, as well as for detection of "any narrowing" and "severe narrowing" of the MCA. Input for each classifier consisted of the peak-systolic, mean and end-diastolic velocities measured with each sonographic method; the output was MCA narrowing. Arterial narrowings less or equal 50% of lumen reduction were found in 55 and >50% narrowings in 26 out of 267 arteries, as indicated by DSA. In the category of "any narrowing" the rate of correct assignment by all models was 82% to 83% for TCCS and 79% to 81% for TCD. In the diagnosis of >50% narrowing the overall classification accuracy remained in the range of 89% to 90% for TCCS data and 90% to 91% for TCD data. For the diagnosis of any narrowing, the sensitivity of the TCCS was significantly higher than that of the TCD, while for diagnosis of >50% MCA narrowing, sensitivity of the TCCS was similar to sensitivity of the TCD. Our study showed that TCCS outperforms conventional TCD in detection of < or =50% MCA narrowing, whereas no significant difference in accuracy between both methods was found in the diagnosis of >50% MCA narrowing. (E-mail: jaroslaw.krejza@uphs.upenn.edu).

  9. Duplex investigations in children: Are clinical signs in children with venous disorders relevant?

    PubMed

    Birgitte Maessen-Visch, M; Smeets, L; van Vleuten, C

    2015-12-01

    Ultra sound colored duplex sonography is the preferred method in diagnosing chronic venous disease. Data in children on incidence, indications, and results are lacking. From the total of 9180 duplex investigations performed in our hospital from 2009 to 2012, data on indication and results of the investigation as well as patient characteristics were evaluated retrospectively for the proportion of pediatric patients. Duplex investigations were performed 49 times in 38 children (6-18 years), with an average of 1.3 times (1-6 times) per child. Forty percent showed abnormalities: 17 times deep venous thrombosis was suspected; deep venous thrombosis was objectified in 18%. In the 21 investigations performed for varicosis-related complaints, varicose veins or venous malformations were objectified in 57%. Edema was never a symptom of chronic venous disease. Duplex investigation is not often performed in children. In children with established deep venous thrombosis, a family history with deep venous thrombosis is common. In general, edema was not seen in children with varicose veins and, therefore, does not seem a reliable clinical sign at young age. © The Author(s) 2014.

  10. [Can TOF MRA replace duplex and Doppler sonography in preoperative assessment of the carotid arteries? A prospective comparison and review of the literature].

    PubMed

    Krappel, F A; Bauer, E; Harland, U

    2002-01-01

    To examine the quality and usefulness of time-of-flight MR-angiography and duplex-doppler sonography, respectively, in assessment of the extracranial arteries before cervical spine operations. Patients scheduled for operations of the cervical spine had an MRI plus TOF as well as a duplex and Doppler scan. At the time of the examination the radiologist and the neurologist in charge were blinded for the study. Endpoints were not only the accuracy of the procedures but more so which method improved the preoperative process most. Twenty patients were examined so far. Only in one case did the result differ when a complete occlusion diagnosed sonographically was judged as a severe stenosis on MRA. One patient did not tolerate the MRA for the extra 5 minutes necessary, therefore a contrast-enhanced MRA was performed. MRA eased the preoperative process as imaging of the pathology and the carotids were realised in one step. The costs were slightly higher for MRA than for duplex-doppler sonography. TOF-MRA can replace the duplex-doppler examination in the preoperative assessment of the carotids and has the potential to streamline the preoperative time schedule. Similar to duplex and doppler, in order to be accurate enough the method requires a high degree of expertise from the radiologist.

  11. Comparative study evaluating the role of color Doppler sonography and computed tomography in predicting chest wall invasion by lung tumors.

    PubMed

    Sripathi, Smiti; Mahajan, Abhishek

    2013-09-01

    To analyze qualitative and quantitative parameters of lung tumors by color Doppler sonography, determine the role of color Doppler sonography in predicting chest wall invasion by lung tumors using spectral waveform analysis, and compare color Doppler sonography and computed tomography (CT) for predicting chest wall invasion by lung tumors. Between March and September 2007, 55 patients with pleuropulmonary lesions on chest radiography were assessed by grayscale and color Doppler sonography for chest wall invasion. Four patients were excluded from the study because of poor acoustic windows. Quantitative and qualitative sonographic examinations of the lesions were performed using grayscale and color Doppler imaging. The correlation between the color Doppler and CT findings was determined, and the final outcomes were correlated with the histopathologic findings. Of a total of 51 lesions, 32 were malignant. Vascularity was present on color Doppler sonography in 28 lesions, and chest wall invasion was documented in 22 cases. Computed tomography was performed in 24 of 28 evaluable malignant lesions, and the findings were correlated with the color Doppler findings for chest wall invasion. Of the 24 patients who underwent CT, 19 showed chest wall invasion. The correlation between the color Doppler and CT findings revealed that color Doppler sonography had sensitivity of 95.6% and specificity of 100% for assessing chest wall invasion, whereas CT had sensitivity of 85.7% and specificity of 66.7%. Combined qualitative and quantitative color Doppler sonography can predict chest wall invasion by lung tumors with better sensitivity and specificity than CT. Although surgery is the reference standard, color Doppler sonography is a readily available, affordable, and noninvasive in vivo diagnostic imaging modality that is complementary to CT and magnetic resonance imaging for lung cancer staging.

  12. Transfontanellar duplex brain ultrasonography resistive indices as a prognostic tool in neonatal hypoxic-ischemic encephalopathy before and after treatment with therapeutic hypothermia.

    PubMed

    Gerner, G J; Burton, V J; Poretti, A; Bosemani, T; Cristofalo, E; Tekes, A; Seyfert, D; Parkinson, C; Leppert, M; Allen, M; Huisman, T A G M; Northington, F J; Johnston, M V

    2016-03-01

    Prior to therapeutic hypothermia (that is, cooling), transfontanellar duplex brain sonography resistive indices (RI) were studied as a bedside non-invasive measures of cerebral hemodynamics in neonates who suffered from hypoxic-ischemic encephalopathy (HIE). We compared pre- and post-cooling RI values and examined the relationships between RI values and specific long-term neurodevelopmental outcomes. Transfontanellar duplex brain sonography, including RI, were obtained for 28 neonates prior to cooling and for 20 neonates following cooling. All RI values were sampled in the anterior cerebral artery at the beginning of each ultrasound study. Neurodevelopmental assessment was conducted between ages 20-32 months with the Mullen Scale of Early Learning. The relationships between pre- and post-cooling RI and cognitive and motor outcomes were studied. Neonates with RI values <0.60 prior to and following cooling were more likely to die or have severe neurodevelopmental disability by ages 20-32 months than those with RI>0.60. Lower RI values were associated with specific neurodevelopmental deficits in motor skill attainment. Pre- and post-cooling transfontanellar duplex brain sonography RI values may be a useful prognostic tool, in conjunction with other clinical information, for neonates diagnosed with HIE. The results of this study suggest that further study of the prognostic value of RI values for short- and long-term outcomes is warranted.

  13. [Sonoelastography, B-mode sonography, and color Doppler sonography findings of pleomorphic adenomas and Warthin tumors of parotid gland].

    PubMed

    Yerli, Hasan; Eşki, Erkan

    2015-01-01

    This study aims to investigate the sonoelastography (SE), B-mode sonography, and color Doppler sonography findings of the pleomorphic adenomas and Warthin tumors of the parotid gland. A total of 84 parotid masses (23 pleomorphic adenomas, 25 Warthin tumors) in 72 patients (37 males, 35 females; mean age 59 years; range 30 to 79 years) were retrospectively analyzed. For each lesion, B-mode sonography, color Doppler sonography, and SE images were evaluated. Vascularity and elasticity scores of the tumors during color Doppler sonography and SE examinations were calculated by 4-scoring method. Lobulated contour and cystic areas were more common in the pleomorphic adenomas and Warthin tumors during the B-mode sonography examination (p<0.05). Peripheral vascularity was common in more than half of the pleomorphic adenoma patients, whereas central or mixed vascularity was seen in a large group of the Warthin tumor patients (p<0.05). The mean scores on color Doppler sonography examination were 1.13±0.81 for pleomorphic adenomas and 1.96±0.97 for Warthin tumors (p<0.05). The mean scores on SE examination were 2.69±0.70 for pleomorphic adenomas and 1.83±0.63 for Warthin tumors (p<0.05). Score 1 on SE examination was found in three of five Warthin tumor patients with peripheral vascularity on color Doppler sonography. B-mode, color Doppler and elastography examinations by sonography provide some helpful findings in the differentiation of pleomorphic adenomas and Warthin tumors.

  14. Comparison Between Various Color Spectra and Conventional Grayscale Imaging for Detection of Parenchymal Liver Lesions With B-Mode Sonography.

    PubMed

    Merkel, Daniel; Brinkmann, Eckard; Kämmer, Joerg C; Köhler, Miriam; Wiens, Daniel; Derwahl, Karl-Michael

    2015-09-01

    The electronic colorization of grayscale B-mode sonograms using various color schemes aims to enhance the adaptability and practicability of B-mode sonography in daylight conditions. The purpose of this study was to determine the diagnostic effectiveness and importance of colorized B-mode sonography. Fifty-three video sequences of sonographic examinations of the liver were digitized and subsequently colorized in 2 different color combinations (yellow-brown and blue-white). The set of 53 images consisted of 33 with isoechoic masses, 8 with obvious lesions of the liver (hypoechoic or hyperechoic), and 12 with inconspicuous reference images of the liver. The video sequences were combined in a random order and edited into half-hour video clips. Isoechoic liver lesions were successfully detected in 58% of the yellow-brown video sequences and in 57% of the grayscale video sequences (P = .74, not significant). Fifty percent of the isoechoic liver lesions were successfully detected in the blue-white video sequences, as opposed to a 55% detection rate in the corresponding grayscale video sequences (P= .11, not significant). In 2 subgroups, significantly more liver lesions were detected with grayscale sonography compared to blue-white sonography. Yellow-brown-colorized B-mode sonography appears to be similarly effective for detection of isoechoic parenchymal liver lesions as traditional grayscale sonography. Blue-white colorization in B-mode sonography is probably not as effective as grayscale sonography, although a statistically significant disadvantage was shown only in the subgroup of hyperechoic liver lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Feasibility of transabdominal Doppler sonography for studying uterine blood flow characteristics in cycling gilts.

    PubMed

    Herlta, Catherine; Starka, Rosa; Sigmarsson, Haukur L; Kauffold, Johannes

    2018-06-01

    To test for the feasibility of transabdominal Doppler sonography (color, power, pulse wave) to define uterine perfusion characteristics throughout the estrous cycle in gilts. A total of 15 gilts were synchronized for estrus and scanned in their following spontaneous cycle while being restrained in a purpose-designed mobile crate. To define uterine perfusion characteristics, vessels in between and within uterine cross-sections were imaged and recorded as video sequences to be analyzed by PixelFlux® software for perfused area (Amix), blood flow velocity (vmix) and intensity (Imix) as well as resistance (RIvmix) and pulsatility index (PIvmix). Color Doppler sonography proved to be the only feasible technique, as it was less affected by animal movements than power and pulse wave sonography. As determined by color Doppler sonography, all five parameters determined showed specific patterns through the estrous cycle, i. e. Amix, vmix, Imix were high in proestrus, decreased in estrus and remained low in midestrus and most parts of diestrus; RIvmix and PIvmix with inversely paralleled patterns. This study has demonstrated that transabdominal color Doppler but not power and pulse wave Doppler sonography is feasible to be performed in crate-restrained gilts for studying uterine perfusion characteristics during the estrous cycle, and that changes of uterine perfusion over the course of the estrous cycle can be clearly followed by color Doppler sonography. Results encourage the use of color Doppler sonography for studying i. e. uterine capacity or uterus related infertility such as for cases of clinically unapparent endometritis. Schattauer GmbH.

  16. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    PubMed

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  17. Assessment of intracranial venous blood flow after subarachnoid hemorrhage: a new approach to diagnose vasospasm with transcranial color-coded duplex sonography.

    PubMed

    Connolly, Florian; Schreiber, Stephan J; Leithner, Christoph; Bohner, Georg; Vajkoczy, Peter; Valdueza, José M

    2017-12-15

    OBJECTIVE Transcranial color-coded duplex sonography (TCCS) is a reliable tool that is used to assess vasospasm in the M 1 segment of the middle cerebral artery (MCA) after subarachnoid hemorrhage (SAH). A distinct increase in blood flow velocity (BFV) is the principal criterion for vasospasm. The MCA/internal carotid artery (ICA) index (Lindegaard Index) is also widely used to distinguish between vasospasm and cerebral hyperperfusion. However, extracranial ultrasonography assessment of the neck vessels might be difficult in an intensive care unit. Therefore, the authors evaluated whether the relationship of intracranial arterial to venous BFV might indicate vasospasm with similar or even better accuracy. METHODS Patients who presented between 2008 and 2015 with aneurysmal SAH were prospectively enrolled in the study. Digital subtraction angiography (DSA) and TCCS were performed within 24 hours of each other to assess vasospasm 8-10 days after SAH. The following different TCCS parameters were analyzed to assess vasospasm in the MCA and were compared with the gold-standard DSA parameters: 1) mean time-averaged maximum BFV (V mean ) of the MCA, 2) peak systolic velocity (PSV) of the MCA, 3) the Lindegaard Index using V mean as well as PSV, and 4) a new arteriovenous index (AVI) between the MCA and the basal vein of Rosenthal using V mean and PSV. The best cutoff values for these parameters to distinguish vasospasm from normal perfusion or hyperperfusion were calculated using receiver operating characteristic curve analysis. Sensitivity, specificity, positive predictive value, and negative predictive value as well as the overall accuracy for each cutoff value were analyzed. RESULTS A total of 102 patients (mean age 52 ± 12 years) were evaluated. Bilateral MCA assessment by TCCS was successful in all patients. In 6 cases (3%), the BFV of the basal vein of Rosenthal could not be analyzed. The AVI could not be calculated in 50 of 204 cases (25%) because the insonation quality was very low in one of the ICAs. An AVI > 10 for V mean and an AVI > 12 for systolic velocity provided the highest accuracies of 87% and 86%, respectively. Regarding the Lindegaard Index, the accuracy was highest using a threshold of > 3 for the mean BFV (84%) as well as systolic BFV (80%). BFVs in the MCA of ≥ 120 cm/sec (V mean ) and ≥ 200 cm/sec (PSV) predicted vasospasm with accuracies of 84% and 83%, respectively. A combined analysis of the MCA BFV and the AVI led to a slight increase in specificity (V mean , 94%; PSV, 93%) and positive predictive value (V mean , 88%; PSV 86%) without further improvement in accuracy (V mean , 88%; PSV, 84%). CONCLUSIONS The intracranial AVI is a reliable parameter that can be used to assess vasospasm after SAH. Its reliability for differentiating vasospasm and hyperperfusion is slightly higher than that for the established Lindegaard Index, and this method has the additional advantage of a remarkably lower failure rate.

  18. Predictive value of vertebral artery extracranial color-coded duplex sonography for ischemic stroke-related vertigo.

    PubMed

    Liou, Li-Min; Lin, Hsiu-Fen; Huang, I-Fang; Chang, Yang-Pei; Lin, Ruey-Tay; Lai, Chiou-Lian

    2013-12-01

    Vertigo can be a major presentation of posterior circulation stroke and can be easily misdiagnosed because of its complicated presentation. We thus prospectively assessed the predictive value of vertebral artery extracranial color-coded duplex sonography (ECCS) for the prediction of ischemic stroke-related vertigo. The inclusion criteria were: (1) a sensation of whirling (vertigo); (2) intractable vertigo for more than 1 hour despite appropriate treatment; and (3) those who could complete cranial magnetic resonance imaging (MRI) and vertebral artery (V2 segment) ECCS studies. Eventually, 76 consecutive participants with vertigo were enrolled from Kaohsiung Municipal Hsiao-Kang Hospital, Kaohsiung, Taiwan between August 2010 and August 2011. Demographic data, neurological symptoms, neurologic examinations, and V2 ECCS were assessed. We chose the parameters of peak systolic velocity (PSV), end diastolic velocity (EDV), PSV/EDV, mean velocity (MV), resistance index (RI), and pulsatility index (PI) to represent the hemodynamics. Values from both sides of V2 segments were averaged. We then calculated the average RI (aRI), average PI (aPI), average PSV (aPSV)/EDV, and average (aMV). Axial and coronal diffusion-weighted MRI findings determined the existence of acute ischemic stroke. We grouped and analyzed participants in two ways (way I and way II analyses) based on the diffusion-weighted MRI findings (to determine whether there was acute stroke) and neurological examinations. Using way I analysis, the "MRI (+)" group had significantly higher impedance (aRI, aPI, and aPSV/EDV ratio) and lower velocity (aPSV, aEDV, and aMV(PSV + EDV/2)), compared to the "MRI (-)" group. The cutoff value/sensitivity/specificity of aPSV, aEDV, aMV, aPI, aRI, and aPSV/EDV between the MRI (+) and MRI (-) groups were 41.15/61.5/66.0 (p = 0.0101), 14.55/69.2/72.0 (p = 0.0003), 29.10/92.1/38.0 (p = 0.0013), 1.07/76.9/64.0 (p = 0.0066), 0.62/76.9/64.0 (p = 0.0076), and 2.69/80.8/66.0 (p = 0.0068), respectively. Using way II analysis, lower aEDV and aMV, and higher aRI, aPI, and aPSV/EDV ratio could determine the "MRI (+) without focal signs" group. The cutoff value/sensitivity/specificity of aEDV, aMV, aPI, aRI, and aPSV/EDV between the MRI (+) without focal signs and MRI (-) groups were 9.10/71.4/96.0 (p = 0.0005), 15.65/57.1/96.0 (p = 0.0124), 1.10/100/70.0 (p = 0.0002), 0.64/100/70.0 (p = 0.0023), and 2.80/100/70.0 (p = 0.0017), respectively. In conclusion, using demographic data and clinical symptoms, it was difficult to determine the patients with ischemic stroke-related vertigo. Although neurological examinations still have diagnostic value, the high impedance and low velocity pattern of V2 ECCS can be an add-on method for the screening of acute ischemic stroke-related vertigo, even for those without focal neurological signs. Copyright © 2013. Published by Elsevier B.V.

  19. Sonography of pediatric superficial lumps and bumps: illustrative examples from head to toe.

    PubMed

    Bansal, Anmol Gupta; Rosenberg, Henrietta Kotlus

    2017-08-01

    Superficial lumps and bumps are extremely common in children, and the vast majority ultimately prove to be benign. Duplex/color Doppler ultrasound (US) has emerged as the first-line imaging modality for the evaluation of these superficial pediatric masses because it provides a means for rapid acquisition of information including size, shape, location, internal content and vascularity. More important, it does so without utilizing radiation, iodinated contrast material or sedation/anesthesia. In this review, we present the sonographic findings of a variety of cases ranging from head to toe that are either uncommonly seen or were diagnosed in an atypical fashion (i.e. ultrasound). In situations where the lesion is too deep, hyperechoic or large to be fully assessed within the field of view or if malignancy is suspected, then additional cross-sectional imaging is warranted for further evaluation.

  20. Usefulness of color Doppler sonography in a growing skull fracture: case report.

    PubMed

    Yoshioka, H; Sakoda, K; Kohno, H; Hada, H; Kurisu, K

    1997-01-01

    A case of an 11-month-old infant with a growing skull fracture is described. The patient was admitted with disturbance of consciousness and left hemiparesis after a severe head injury. A pulsating protrusion appeared over the fracture line 1 month later. Color Doppler sonography revealed cerebral herniation and cystic lesion via the bony defect, together with an intracranial arterial flow pattern detected in the extracranial space. Color Doppler sonography was very useful in the diagnosis of growing skull fracture and in the evaluation of the intracranial state, including hemodynamics in this case. Successful surgical treatment was performed on the basis of sonographic data and the patient was discharged 3 months later without motor deficits.

  1. Development of a Duplex Ultrasound Simulator and Preliminary Validation of Velocity Measurements in Carotid Artery Models.

    PubMed

    Zierler, R Eugene; Leotta, Daniel F; Sansom, Kurt; Aliseda, Alberto; Anderson, Mark D; Sheehan, Florence H

    2016-07-01

    Duplex ultrasound scanning with B-mode imaging and both color Doppler and Doppler spectral waveforms is relied upon for diagnosis of vascular pathology and selection of patients for further evaluation and treatment. In most duplex ultrasound applications, classification of disease severity is based primarily on alterations in blood flow velocities, particularly the peak systolic velocity (PSV) obtained from Doppler spectral waveforms. We developed a duplex ultrasound simulator for training and assessment of scanning skills. Duplex ultrasound cases were prepared from 2-dimensional (2D) images of normal and stenotic carotid arteries by reconstructing the common carotid, internal carotid, and external carotid arteries in 3 dimensions and computationally simulating blood flow velocity fields within the lumen. The simulator displays a 2D B-mode image corresponding to transducer position on a mannequin, overlaid by color coding of velocity data. A spectral waveform is generated according to examiner-defined settings (depth and size of the Doppler sample volume, beam steering, Doppler beam angle, and pulse repetition frequency or scale). The accuracy of the simulator was assessed by comparing the PSV measured from the spectral waveforms with the true PSV which was derived from the computational flow model based on the size and location of the sample volume within the artery. Three expert examiners made a total of 36 carotid artery PSV measurements based on the simulated cases. The PSV measured by the examiners deviated from true PSV by 8% ± 5% (N = 36). The deviation in PSV did not differ significantly between artery segments, normal and stenotic arteries, or examiners. To our knowledge, this is the first simulation of duplex ultrasound that can create and display real-time color Doppler images and Doppler spectral waveforms. The results demonstrate that an examiner can measure PSV from the spectral waveforms using the settings on the simulator with a mean absolute error in the velocity measurement of less than 10%. With the addition of cases with a range of pathologies, this duplex ultrasound simulator will be a useful tool for training health-care providers in vascular ultrasound applications and for assessing their skills in an objective and quantitative manner. © The Author(s) 2016.

  2. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    PubMed

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  3. Marked Increase in Flow Velocities During Deep Expiration: A Duplex Doppler Sign of Celiac Artery Compression Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erden, Ayse; Yurdakul, Mehmet; Cumhur, Turhan

    1999-07-15

    Symptoms of chronic mesenteric ischemia develop when the celiac artery is constricted by the median arcuate ligament of the diaphragm. Lateral aortography is the primary modality for diagnosing ligamentous compression of the celiac artery. However, duplex Doppler sonography performed during deep expiration can cause a marked increase in flow velocities at the compressed region of the celiac artery and suggest the diagnosis of celiac arterial constriction due to the diaphragmatic ligament. RID='''' ID='''' Correspondence to: A. Erden, M.D., Hafta sokak. 23/6, Gaziosmanpasa, 06700 Ankara, Turkey.

  4. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    PubMed

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  5. Spontaneous Recanalization After Carotid Artery Dissection: The Case for an Ultrasound-Only Monitoring Strategy

    PubMed Central

    Lumsden, Sarah; Rosta, Gabor; Bismuth, Jean; Lumsden, Alan B.; Garami, Zsolt

    2017-01-01

    Dissection of the internal carotid artery (ICA) accounts for 5% to 25% of ischemic strokes in young adults. We report a case of spontaneous recanalization of a traumatic ICA dissection in which carotid duplex (CDU) and transcranial color-coded duplex ultrasound (TCCD) were used. A 47-year-old male presented with intermittent episodes of headache, blurry vision, anisocoria, and loss of taste sensation following a whiplash injury while body surfing. Magnetic resonance angiogram (MRA) of the neck revealed absent flow in the cavernous ICA and a clot at the skull base. Carotid duplex, used to further evaluate flow, demonstrated reverberating color Doppler and spectrum signal. A TCCD showed ICA occlusion and smaller-caliber intracranial ICA. The patient reported for follow-up after 1 month on anticoagulation therapy. Upon his return, CDU and TCCD were normal and the ICA showed normal color and spectrum signals. Computed tomography angiogram confirmed ultrasound findings of a dramatic improvement of ICA patency. Additionally, the patient reported that his headaches had resolved. Extracranial CDU and TCCD are useful for monitoring patient progress in cases of spontaneous recanalization following carotid artery dissection. These inexpensive and noninvasive imaging modalities proved to be critical in the initial and follow-up evaluations of the extracranial and intracranial vascular system, providing a strong alternative to expensive magnetic resonance imaging and invasive angiograms and offering more hemodynamic information than “static” MRA. PMID:29744017

  6. [Thrombosis and post-thrombotic syndrome as a consequence of an accident].

    PubMed

    Wahl, U; Hirsch, T

    2015-10-01

    Phlebothromboses represent alarming complications in accident victims since they can cause fatal pulmonary embolisms. More than half of those affected also develop post-thrombotic syndrome in the course of the illness. In addition to making clinical assessments, the traumatologist should also have fundamental knowledge about diagnostic methods and be familiar with interpreting internal findings. Colour-coded duplex sonography plays a central role in diagnosing thrombosis and in assessing functional limitations. Further information can be gathered from various phlebological procedures. The expert evaluation of the immediate, as well as the long-term consequences of an accident frequently require leg swelling to be classified. It is not uncommon for post-thrombotic syndrome to be diagnosed for the first time during this process. An additional vascular appraisal is often required. An appreciation of social-medical and insurance-related aspects means a high degree of responsibility is placed on the expert.

  7. Color-coded perfusion analysis of CEUS for pre-interventional diagnosis of microvascularisation in cases of vascular malformations.

    PubMed

    Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M

    2014-01-01

    Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.

  8. Middle cerebral arterial flow changes on transcranial color and spectral Doppler sonography in patients with increased intracranial pressure.

    PubMed

    Wang, Yu; Duan, Yun-You; Zhou, Hai-Yan; Yuan, Li-Jun; Zhang, Li; Wang, Wei; Li, Li-Hong; Li, Liang

    2014-12-01

    Intracranial pressure usually increases after severe brain injury. However, a method for noninvasive evaluation of intracranial pressure is still lacking. The purpose of this study was to explore the potential role of transcranial color Doppler sonography in assessing intracranial pressure by observing the middle cerebral artery blood flow parameters in patients with increased intracranial pressure of varying etiology. The hemodynamic changes in the middle cerebral artery in patients with varying degrees of increased intracranial pressure were investigated by transcranial color Doppler sonography in 93 patients who had emergency surgery for brain injury. Middle cerebral artery Doppler flow spectra changed regularly as intracranial pressure increased. The pulsatility index (PI) and resistive index (RI) had a significantly positive correlation with intracranial pressure (r = 0.90 and 0.89, respectively; P< .001), whereas the middle cerebral artery diastolic velocity showed a significant negative correlation with intracranial pressure (r = -0.52; P< .01). A receiver operating characteristic curve showed that the RI and PI cutoff values were 0.705 and 1.335, respectively, for predicting increased intracranial pressure, with sensitivity of 0.885 and specificity of 0.970. In addition to the PI and RI, middle cerebral artery diastolic flow velocity measurement by transcranial color Doppler sonography may also be a useful variable for evaluating intracranial pressure in patients with acute brain injury. © 2013 by the American Institute of Ultrasound in Medicine.

  9. Color Doppler Sonographic and Cadaveric Study of the Arterial Vascularity of the Lateral Upper Arm Flap.

    PubMed

    Sun, Ruimei; Ding, Yu; Sun, Chuanzheng; Li, Xiaojiang; Wang, Jinde; Li, Lei; Yang, Jie; Ren, Yanxin; Zhong, Zhaoming

    2016-04-01

    To determine the importance of adequate preoperative assessment with color Doppler sonography to assist in the successful transfer of lateral upper arm flaps by studying the lateral upper arm flap with color Doppler sonography and analyzing the anatomic features of the radial collateral artery. A clinical case-control study was performed. The radial collateral artery was studied with color Doppler sonography in 15 healthy volunteers. The origins, courses, variations, and locations of the perforators of the radial collateral artery were recorded. The results and data from the color Doppler sonographic investigation were compared with an anatomic study that was performed on 22 adult cadaveric upper limb specimens. The volunteer group (14 of 15 volunteers) and the cadaveric group (19 of 22 upper arm specimens) clearly showed that the branch pattern of the arterial supply was as follows: brachial artery → deep brachial artery → radial collateral artery → posterior radial collateral artery → myocutaneous perforator. Variations in the origin of the radial collateral artery were identified in 1 volunteer bilaterally and in 3 upper arm specimens. The diameters of the artery and vein measured at the distal insertion of the deltoid and the origin of the deep brachial artery were not significantly different between the volunteer and cadaver groups (P > .05). Due to the difference in measuring methods, the length of the vascular pedicles was significantly different between the groups (P < .05). Color Doppler sonography can facilitate the preoperative assessment of the origin, course, variations, and locations of the radial collateral artery and therefore may increase the success rate of lateral upper arm flap transfer. © 2016 by the American Institute of Ultrasound in Medicine.

  10. MicroV Technology to Improve Transcranial Color Coded Doppler Examinations.

    PubMed

    Malferrari, Giovanni; Pulito, Giuseppe; Pizzini, Attilia Maria; Carraro, Nicola; Meneghetti, Giorgio; Sanzaro, Enzo; Prati, Patrizio; Siniscalchi, Antonio; Monaco, Daniela

    2018-05-04

    The purpose of this review is to provide an update on technology related to Transcranial Color Coded Doppler Examinations. Microvascularization (MicroV) is an emerging Power Doppler technology which can allow visualization of low and weak blood flows even at high depths, thus providing a suitable technique for transcranial ultrasound analysis. With MicroV, reconstruction of the vessel shape can be improved, without any overestimation. Furthermore, by analyzing the Doppler signal, MicroV allows a global image of the Circle of Willis. Transcranial Doppler was originally developed for the velocimetric analysis of intracranial vessels, in particular to detect stenoses and the assessment of collateral circulation. Doppler velocimetric analysis was then compared to other neuroimaging techniques, thus providing a cut-off threshold. Transcranial Color Coded Doppler sonography allowed the characterization of vessel morphology. In both Color Doppler and Power Doppler, the signal overestimated the shape of the intracranial vessels, mostly in the presence of thin vessels and high depths of study. In further neurosonology technology development efforts, attempts have been made to address morphology issues and overcome technical limitations. The use of contrast agents has helped in this regard by introducing harmonics and subtraction software, which allowed better morphological studies of vessels, due to their increased signal-to-noise ratio. Having no limitations in the learning curve, in time and contrast agent techniques, and due to its high signal-to-noise ratio, MicroV has shown great potential to obtain the best morphological definition. Copyright © 2018 by the American Society of Neuroimaging.

  11. Eco-Doppler evaluation of intestinal peristalsis in normal and in some pathological conditions: preliminary data.

    PubMed

    La Bella, A; Gimondo, P; Camboni, M

    1993-01-01

    Duplex-Doppler sonography could be employed in the quantitative investigation of intestinal motility. Preliminary data indicate reproductivity of the method in normal subjects and possible clinical applications in some pathological conditions affecting intestinal transit. Particularly, the possibility to discriminate between segments at different peristaltic activity seems to be very useful in intestinal obstruction. Further studies are necessary to validate this method.

  12. Screen for intracranial dural arteriovenous fistulae with carotid duplex sonography.

    PubMed

    Tsai, L-K; Yeh, S-J; Chen, Y-C; Liu, H-M; Jeng, J-S

    2009-11-01

    Early diagnosis and management of intracranial dural arteriovenous fistulae (DAVF) may prevent the occurrence of stroke. This study aimed to identify the best carotid duplex sonography (CDS) parameters for screening DAVF. 63 DAVF patients and 170 non-DAVF patients received both CDS and conventional angiography. The use of seven CDS haemodynamic parameter sets related to the resistance index (RI) of the external carotid artery (ECA) for the diagnosis of DAVF was validated and the applicability of the best CDS parameter set in 20 400 patients was tested. The CDS parameter set (ECA RI (cut-off point = 0.7) and internal carotid artery (ICA) to ECA RI ratio (cut-off point = 0.9)) had the highest specificity (99%) for diagnosis of DAVF with moderate sensitivity (51%). Location of the DAVF was a significant determinant of sensitivity of detection, which was 70% for non-cavernous DAVF and 0% for cavernous sinus DAVF (p<0.001). The above parameter set detected abnormality in 92 of 20 400 patients. These abnormalities included DAVF (n = 25), carotid stenosis (n = 32), vertebral artery stenosis (n = 7), intracranial arterial stenosis (n = 6), head and neck tumour (n = 3) and unknown aetiology (n = 19). Combined CDS parameters of ECA RI and ICA to ECA RI ratio can be used as a screening tool for the diagnosis of DAVF.

  13. Three-dimensional gadolinium-enhanced magnetic resonance venography in suspected thrombo-occlusive disease of the central chest veins.

    PubMed

    Kroencke, T J; Taupitz, M; Arnold, R; Fritsche, L; Hamm, B

    2001-11-01

    To determine the usefulness of high-resolution three-dimensional (3D) gadolinium-enhanced magnetic resonance venography (MRV) in the evaluation of central venous thrombo-occlusive disease of the chest. Prospective study. University hospital. Sixteen consecutive patients with clinically suspected thrombosis of the superior vena cava, subclavian, brachiocephalic/innominate, internal jugular, or axillary veins. Thirteen patients had a neoplasm, two patients had a connective tissue disease, and one patient had a history of strenuous exercise. Twelve of 16 patients had prior central venous catheter placement. MRI was correlated with color-coded duplex sonography (CCDS) in 7 of 16 patients, digital subtraction angiography (DSA) in 3 of 16 patients, and CT in 2 of 16 patients. Contrast-enhanced MRV was performed in a total of 20 examinations. A 3D data set (gradient echo; time to repeat, 4.6 ms; time to echo, 1.8 ms; flip angle, 30 degrees; time of acquisition, 23 s; 512 matrix/64 partitions; slice thickness, 1.5 mm) was acquired in the arterial and venous phase. Overall image quality was assessed on a 5-point scale. The presence, site, and extent of thrombus, as well as presence of an intravascular device, were determined. Overall image quality was rated very good (1 point) in 7 of 16 cases (44%) and good (2 points) in 9 of 16 cases (56%). Thrombus was detected in 16 of 16 patients, and complete extent of disease could be determined in 15 of 16 patients (94%). MRV did not miss any finding obtained by CCDS, DSA, or CT, and provided additional information in 6 of 16 examinations (38%). Contrast-enhanced MRV is a fast and reliable noninvasive procedure with excellent results regarding detection and determination of the extent of thrombo-occlusive disease of the chest veins.

  14. Refraction and the axial length of the eyeball in patients with the optic disc drusen.

    PubMed

    Obuchowska, Iwona; Mariak, Zofia

    2009-01-01

    The aim of the study was to demonstrate the relationship between the optic disc drusen (ODD) and the axial length of the eyeball as well as refractive error. We examined prospectively 40 patients with ODD, 18 men and 22 women, age range from 34 to 69 years. All subjects underwent full ophthalmic examination, visual field testing and color-coded duplex sonography of the ocular vessels. Refraction was determined with an autorefractometer (Topcon RM-8000B) and further refined subjectively. Spherical equivalent refraction was calculated as the spherical dioptre plus one half of the cylindrical dioptre. Axial lengths were measured with a Sonomed ultrasound scanner model E-Z Scan AB5500. Clinical signs were observed in 65% of the eyes with drusen, among them, 38% had symptoms of visual acuity loss and all had visual fields defects. There were 21 eyes (18 eyes with and 3 without drusen), with a recorded refractive error. Significant differences in hyperopia were observed between the eyes with and without drusen (p = 0.048). The rate of occurrence of myopia did not differ significantly between affected and unaffected eyes (p = 0.06). The mean spherical equivalent refraction and axial dimensions of the eye differed significantly among the groups of eyes with and without drusen (p < 0.05). Significant differences in mean values of peak-systolic and end-diastolic velocities (p < 0.001) as well as in the resistivity index (p = 0.047) were observed between eyes with and without drusen. The optic disc drusen are often associated with shorter and hyperopic eyes. This anatomical conditions and vascular factors may contribute to pathogenesis of drusen.

  15. Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Liebl, Andrea; Poullos, Nektarios

    Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36more » h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.« less

  16. Uncommon incidental pseudoaneurysm. Diagnostic and management challenges.

    PubMed

    Hadidy, Azmy M; Samara, Osama A; Takrouri, Heba S; Al-Ryalat, Nosaiba T; Al-Smady, Moaath M; Ryalat, Soukaina T; Abu-Khalaf, Mahmoad M

    2009-08-01

    To analyze patients with uncommon incidental pseudoaneurysms, secondary to non-catheterization causes, and to discuss the peculiar clinical spectrum, and focus on some aspects of difference from post-catheterization pseudoaneurysms. Eleven patients, 8 males and 3 females, were studied retrospectively in Jordan University Hospital, Amman, Jordan, between 2002-2008. Radiological studies performed included duplex sonography (DS), computed tomography (CT), conventional angiography, magnetic resonance imaging (MRI), and magnetic resonance angiography (MRA). Pseudoaneurysms were most commonly encountered in young males (63.6%), especially in the lower limb vessels (36%). Clinical findings were suggestive of pseudoaneurysms in 27% of our cases. Four out of the 8 DS scans showed the neck of pseudoaneurysms, and the to and fro waveform, the strongest indicators for pseudoaneurysms. Both CT with intravenous contrast and angiography failed to establish the diagnosis in one out of 5 cases. The MRI with MRA showed the pseudoaneurysms in 2 patients that underwent the scan. Incidental pseudoaneurysms are considered following iatrogenic procedures, penetrating, or blunt traumas with variable delay time. Young healthy males are at increased risks, as opposed to elderly females with calcified vessels in post-catheterization cases. Duplex sonography is less sensitive in incidental than post-catheterization pseudoaneurysms. The CT scan with intravenous contrast has high accuracy in establishing the diagnosis in small, or medium sized pseudoaneurysms. The MRI and MRA are accurate valuable studies and comparable to conventional angiography.

  17. Free Energy Gap and Statistical Thermodynamic Fidelity of DNA Codes

    DTIC Science & Technology

    2007-10-01

    reverse-complement unless otherwise stated. For strand x, let Nx denote its complement. A (perfect) Watson - Crick duplex is the joining of complement...is possible for complementary sequences to form a non-perfectly aligned duplex, we will call any x W Nx duplex a Watson - Crick (WC) duplex. Two...DATES COVERED (From - To) 4. TITLE AND SUBTITLE FREE ENERGY GAP AND STATISTICAL THERMODYNAMIC FIDELITY OF DNA CODES 5a. CONTRACT NUMBER FA8750-07

  18. Free Energy Gap and Statistical Thermodynamic Fidelity of DNA Codes (Postprint)

    DTIC Science & Technology

    2007-01-01

    reverse-complement unless otherwise stated. For strand x, let Nx denote its complement. A (perfect) Watson - Crick duplex is the joining of complement...is possible for complementary sequences to form a non-perfectly aligned duplex, we will call any x W Nx duplex a Watson - Crick (WC) duplex. Two...DATES COVERED (From - To) 4. TITLE AND SUBTITLE FREE ENERGY GAP AND STATISTICAL THERMODYNAMIC FIDELITY OF DNA CODES 5a. CONTRACT NUMBER FA8750-07

  19. Color duplex assessment of 4th and 5th internal mammary artery perforators: the pedicles of the medially based lower pole breast flaps.

    PubMed

    Abdel-Monem, Kareem; Elshahat, Ahmed; Abou-Gamrah, Sherif; Eldin Abol-Atta, Hossam; Abd Eltawab, Reda; Massoud, Karim

    2012-01-01

    Reconstruction of a breast after mastectomy using the contralateral lower pole breast flap is an appealing procedure because it uses the tissues that were going to be excised during reduction of the sound breast to achieve symmetry. Literature mentioned that these flaps are supplied by the lower internal mammary artery perforators (IMAPs) with no further details. The aim of this study was to determine the site, size, and number of the 4th and 5th IMAPs by using preoperative color Duplex ultrasound and intraoperative exploration. Twenty breasts in 10 patients who presented for reduction mammoplasty were included in this study. Preoperative color duplex was used to determine IMAPs in the 4th and 5th intercostal spaces. These perforators were localized intraoperatively. Intravenous fluorescein injection was used to determine the perfusion of the lower pole breast flap on the basis of these perforators. Statistically, the 4th IMAPs diameters were significantly larger than the 5th IMAPs diameters (P < .05). The lower pole breast flap was perfused through these perforators. Color Duplex ultrasound is an accurate tool to preoperatively determine the 4th and 5th IMAPs.

  20. Artifacts in Sonography - Part 3.

    PubMed

    Bönhof, Jörg A; McLaughlin, Glen

    2018-06-01

    As a continuation of parts 1 1 and 2 2, this article discusses artifacts as caused by insufficient temporal resolution, artifacts in color and spectral Doppler sonography, and information regarding artifacts in sonography with contrast agents. There are artifacts that occur in B-mode sonography as well as in Doppler imaging methods and sonography with contrast agents, such as slice thickness artifacts and bow artifacts, shadows, mirroring, and artifacts due to refraction that appear, for example, as double images, because they are based on the same formation mechanisms. In addition, there are artifacts specific to Doppler sonography, such as the twinkling artifact, and method-based motion artifacts, such as aliasing, the ureteric jet, and due to tissue vibration. The artifacts specific to contrast mode include echoes from usually highly reflective structures that are not contrast bubbles ("leakage"). Contrast agent can also change the transmitting signal so that even structures not containing contrast agent are echogenic ("pseudoenhancement"). While artifacts can cause problems regarding differential diagnosis, they can also be useful for determining the diagnosis. Therefore, effective use of sonography requires both profound knowledge and skilled interpretation of artifacts. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Imaging By Ultrasound

    PubMed Central

    Kidney, Maria R.

    1986-01-01

    Imaging by ultrasound has dramatically changed the investigation and management of many clinical problems. It is useful in many different parts of the body. In this brief discussion, the following topics are considered: hepatic lesions, bleeding in early pregnancy, gynecological pathology (adnexal lesions), aortic aneurysms, thyroid nodules and scrotal masses. The usefulness of duplex carotid sonography, which combines ultrasonic imaging and Doppler studies, is also discussed. Other topics (gallstones, biliary obstruction, renal calculi, hydronephrosis) are discussed in the appropriate sections. ImagesFigure 1Figure 2Figure 3Figure 4 PMID:21267202

  2. Color Duplex Assessment of 4th and 5th Internal Mammary Artery Perforators: The Pedicles of the Medially Based Lower Pole Breast Flaps

    PubMed Central

    Abdel-Monem, Kareem; Elshahat, Ahmed; Abou-Gamrah, Sherif; Eldin Abol-Atta, Hossam; Abd Eltawab, Reda; Massoud, Karim

    2012-01-01

    Objective: Reconstruction of a breast after mastectomy using the contralateral lower pole breast flap is an appealing procedure because it uses the tissues that were going to be excised during reduction of the sound breast to achieve symmetry. Literature mentioned that these flaps are supplied by the lower internal mammary artery perforators (IMAPs) with no further details. The aim of this study was to determine the site, size, and number of the 4th and 5th IMAPs by using preoperative color Duplex ultrasound and intraoperative exploration. Method: Twenty breasts in 10 patients who presented for reduction mammoplasty were included in this study. Preoperative color duplex was used to determine IMAPs in the 4th and 5th intercostal spaces. These perforators were localized intraoperatively. Intravenous fluorescein injection was used to determine the perfusion of the lower pole breast flap on the basis of these perforators. Results: Statistically, the 4th IMAPs diameters were significantly larger than the 5th IMAPs diameters (P < .05). The lower pole breast flap was perfused through these perforators. Conclusion: Color Duplex ultrasound is an accurate tool to preoperatively determine the 4th and 5th IMAPs. PMID:22292100

  3. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation

    PubMed Central

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-01-01

    Abstract This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation. A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The “whirlpool sign” of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation. A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of “whirlpool sign” for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P < .01) for intestinal necrosis occurrence. Sonography is more accurate in diagnosing suspected malrotation than upper gastrointestinal contrast study. Specific sonographic “whirlpool sign” related to volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia. PMID:29049228

  4. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation.

    PubMed

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-10-01

    This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation.A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The "whirlpool sign" of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation.A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of "whirlpool sign" for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P < .01) for intestinal necrosis occurrence.Sonography is more accurate in diagnosing suspected malrotation than upper gastrointestinal contrast study. Specific sonographic "whirlpool sign" related to volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia.

  5. Superimposed Code Theoretic Analysis of DNA Codes and DNA Computing

    DTIC Science & Technology

    2008-01-01

    complements of one another and the DNA duplex formed is a Watson - Crick (WC) duplex. However, there are many instances when the formation of non-WC...that the user’s requirements for probe selection are met based on the Watson - Crick probe locality within a target. The second type, called...AFRL-RI-RS-TR-2007-288 Final Technical Report January 2008 SUPERIMPOSED CODE THEORETIC ANALYSIS OF DNA CODES AND DNA COMPUTING

  6. Endovascular treatment of popliteal artery segments P1 and P2 in patients with critical limb ischemia: initial experience using a helical nitinol stent with increased radial force.

    PubMed

    Goltz, Jan P; Ritter, Christian O; Kellersmann, Richard; Klein, Detlef; Hahn, Dietbert; Kickuth, Ralph

    2012-06-01

    To evaluate efficacy, safety, and midterm patency of a helical, self-expanding nitinol stent after failed percutaneous transluminal angioplasty (PTA) of popliteal artery segments P1 and P2 in patients with chronic critical limb ischemia (CLI) or lifestyle-limiting claudication. Between February 2009 and March 2011, 40 patients (23 men; mean age 77±10 years) classified as Rutherford category 3 (n = 10) or 4/5 (n = 30) underwent PTA of the proximal and mid popliteal artery followed by implantation of a SUPERA stent for elastic recoil, residual stenosis, or flow-limiting dissection. All patients had an elevated operative risk. Before and after the procedure and during the 12-month follow-up, a clinical investigation, ankle-brachial-index (ABI) measurement, and color-coded duplex sonography and/or digital subtraction angiography were performed. Primary endpoints were limb salvage and anatomical patency at 12 months. Stent implantation was successful in all patients. The major complication rate was 7.5% (an access-site pseudoaneurysm, 2 retroperitoneal hematomas, and 1 death from retroperitoneal bleeding). Mean follow-up was 15.9 months (range 0.5-27.9). The mean baseline ABI of 0.37 significantly increased to 0.91 at 12 months (p<0.01). Three (7.5%) patients underwent bypass surgery owing to lack of clinical improvement (<0.10 improvement in ABI). Primary and secondary patency rates at 12 months in the 34 patients eligible for follow-up were 68.4% and 79.8%, respectively. The major amputation rate was 5% at 1 year. Five (12.5%) in-stent stenoses and 1 of 2 (5.0%) in-stent occlusions were successfully recanalized (the second occlusion was asymptomatic). Implantation of this helical stent into segments of the popliteal artery at the knee joint in CLI patients is a safe and clinically effective bailout method with acceptable intermediate patency.

  7. Intraoperative sonographic assessment of graft patency during extracranial-intracranial bypass.

    PubMed

    Badie, B; Lee, F T; Pozniak, M A; Strother, C M

    2000-09-01

    Extracranial-intracranial (EC-IC) bypass may be necessary to facilitate treatment of unclippable posterior circulation fusiform aneurysms. Although intraoperative digital subtraction angiography (DSA) allows assessment of graft patency, this technique, because of difficulties inherent in performing selective catheterization and angiography in the operating room, has limitations. Duplex sonography, in contrast, is easily performed, and provides information regarding graft patency and blood flow direction during EC-IC bypass procedures. This latter information proved useful in determining the time of parent artery occlusion after two EC-IC bypass procedures performed for treatment of a fusiform midbasilar artery aneurysm.

  8. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    PubMed

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p < 0.0001). The Strecker Tantalum stent (85.9 ± 1.95 cm/sec, p < 0.0001) generated the highest BV values. CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Associations Between Renal Duplex Parameters and Adverse Cardiovascular Events in the Elderly: A Prospective Cohort Study

    PubMed Central

    Pearce, Jeffrey D.; Craven, Timothy E.; Edwards, Matthew S.; Corriere, Matthew A.; Crutchley, Teresa A.; Fleming, Shawn H.; Hansen, Kimberley J.

    2010-01-01

    Background Atherosclerotic renovascular disease is associated with an increased risk of cardiovascular disease (CVD) events. This study examines associations between Doppler-derived parameters from the renal artery and renal parenchyma and all-cause mortality and fatal and nonfatal CVD events in a cohort of elderly Americans. Study Design Cohort study. Setting A subset of participants from the Cardiovascular Health Study (CHS). Through an ancillary study, 870 (70% recruitment) Forsyth County, NC, CHS participants consented to undergo renal duplex sonography to define the prevalence of renovascular disease in the elderly, resulting in 726 (36% men; mean age, 77 years) technically adequate complete studies included in this investigation. Predictor Renal duplex sonography–derived Doppler signals from the main renal arteries and renal parenchyma. Spectral analysis from Doppler-shifted frequencies and angle of insonation were used to estimate renal artery peak systolic and end diastolic velocity (both in meters per second). Color Doppler was used to identify the corticomedullary junction. Using a 3-mm Doppler sample, the parenchymal peak systolic and end diastolic frequency shift (both in kilohertz) were obtained. Resistive index was calculated as (1 – [end diastolic frequency shift/peak systolic frequency shift]) using Doppler samples from the hilar arteries of the left or right kidney with the higher main renal artery peak systolic velocity. Outcomes & Measurements Proportional hazard regression analysis was used to determine associations between renal duplex sonography–derived Doppler signals and CVD events and all-cause mortality adjusted for accepted cardiovascular risk factors. Index CVD outcomes were defined as coronary events (angina, myocardial infarction, and coronary artery bypass grafting/percutaneous coronary intervention), cerebrovascular events (stroke or transient ischemic attack), and any CVD event (angina, congestive heart failure, myocardial infarction, stroke, transient ischemic attack, and coronary artery bypass grafting [CABG]/percutaneous transluminal coronary intervention [PTCI]). Results During follow-up, 221 deaths (31%), 229 CVD events (32%), 122 coronary events (17%), and 92 cerebrovascular events (13%) were observed. Renal duplex sonography–derived Doppler signals from the renal parenchyma were associated independently with all-cause mortality and CVD outcomes. In particular, increased parenchymal end diastolic frequency shift was associated significantly with any CVD event (HR, 0.73; 95% CI, 0.62-0.87; P < 0.001). Marginally significant associations were observed between increases in parenchymal end diastolic frequency shift and decreased risk of death (HR, 0.86; 95% CI, 0.73-1.00; P = 0.06) and decreased risk of cerebrovascular events (HR, 0.78; 95% CI, 0.61-1.01; P = 0.06). Parenchymal end diastolic frequency shift was not significantly predictive of coronary events (HR, 0.84; 95% CI, 0.67-1.06; P = 0.1). Limitations CHS participants showed a “healthy cohort” effect that may underestimate the rate of CVD events in the general population. Conclusion Renal duplex sonographic Doppler signals from the renal parenchyma showed significant associations with subsequent CVD events after controlling for other significant risk factors. In particular, a standard deviation increase in parenchymal end diastolic frequency shift was associated with 27% risk reduction in any CVD event. PMID:20116688

  10. A most spectrum-efficient duplexing system: CDD

    NASA Astrophysics Data System (ADS)

    Lee, William C. Y.

    2001-10-01

    The game to play in wireless communications when it comes to increasing spectrum efficiency is to eliminate interference. Currently, all cellular systems use FDD (Frequency Division Duplexing) in an attempt to eliminate the interference from the adjacent cells. Through the use of many technologies only one type of interference remains and that is the adjacent base-tohome mobile interference. TDD (Time Division Duplexing) has not been used for mobile cellular systems, not only because of the adjacent base-to-home mobile interference, but also because of the additional adjacent base-to-home base interference, and adjacent mobile-to-home mobile interference. Therefore, TDD can only be used for small, confined area systems. CDD (Code Division Duplexing) can eliminate all three kinds of interference; the adjacent base-to-home mobile, the adjacent baseto-home base, and the adjacent mobile- to- home in cellular systems. Eliminating each of these interferences makes CDD the most spectrum efficient duplexing system. This talk will elaborate on a set of smart codes, which will make an efficient CDD system a reality.

  11. Diagnostic value of high-resolution B-mode and power-mode sonography in the follow-up of thyroid cancer.

    PubMed

    Görges, Rainer; Eising, E G; Fotescu, D; Renzing-Köhler, K; Frilling, A; Schmid, K W; Bockisch, A; Dirsch, O

    2003-02-01

    Ultrasonography is an established diagnostic modality in the follow-up of thyroid cancer. Color flow Doppler has been proposed by some authors as an additional tool for differentiating benign from malignant cervical lesions in various types of head and neck cancer. Over the last few years, a new generation of high-resolution ultrasound platforms with the "power-mode" feature has become available, that also enables the imaging of small vessel blood flow. The objective of our study was to find ways of optimizing the differentiation of benign and malignant cervical tumors in thyroid cancer follow-up by means of sonography. Hundred and twelve cervical lesions in 90 patients with thyroid cancer were evaluated by high-end ultrasonography (Sonoline Elegra, Siemens) using a small-part transducer (7.5 L 40, Siemens). B-mode sonography was performed at a frequency of 8 MHz. The Solbiati index (SI= ratio of largest to smallest diameter), configuration, echogenicity, intranodular structures, and margins were assessed. Perinodular and intranodular blood flow was evaluated by color flow Doppler (PRF 1250 Hz for conventional color flow Doppler, 868 Hz for power-mode Doppler). Possible malignancy was validated by histology, cytology, scintigraphy, and follow-up. Thirty five lesions were benign (diameter 0.4-3.0 cm) and 77 were malignant (0.4-5.4 cm). The patients were randomized into a test group and a learning group to determine the diagnostic value of various ultrasound criteria by means of statistical analysis. In the learning group, decision rules based on the dichotomized criteria were developed using a logistic regression model. Sensitivity and specificity of these decision rules were then evaluated in the test group. The presence of an echocomplex pattern or irregular hyperechoic small intranodular structures (criterion A) and the presence of an irregular diffuse intranodular blood flow (criterion B) are the best indicators of malignancy, whereas an SI >2 is highly indicative of benign changes. Color flow Doppler is a useful addition to B-mode scanning for distinguishing benign and malignant neoplasms in the follow-up of thyroid cancer. Power-mode Doppler sonography significantly improves imaging of perinodular and intranodular blood flow when compared with conventional color flow Doppler. We propose the following decision rules based on a combination of the criteria above: (A) and (B) fulfilled: malignant, if SI< or =4; (B) but not (A) fulfilled: malignant, if SI< or =3; (A) but not (B) fulfilled: malignant, if SI< or =2; neither (A) nor (B) fulfilled: malignant, if SI approximately equal to 1 (sensitivity: 90%; specificity: 82%; accuracy 88%).

  12. An unusual mode of DNA duplex association: Watson-Crick interaction of all-purine deoxyribonucleic acids.

    PubMed

    Battersby, Thomas R; Albalos, Maria; Friesenhahn, Michel J

    2007-05-01

    Nucleic acid duplexes associating through purine-purine base pairing have been constructed and characterized in a remarkable demonstration of nucleic acids with mixed sequence and a natural backbone in an alternative duplex structure. The antiparallel deoxyribose all-purine duplexes associate specifically through Watson-Crick pairing, violating the nucleobase size-complementarity pairing convention found in Nature. Sequence-specific recognition displayed by these structures makes the duplexes suitable, in principle, for information storage and replication fundamental to molecular evolution in all living organisms. All-purine duplexes can be formed through association of purines found in natural ribonucleosides. Key to the formation of these duplexes is the N(3)-H tautomer of isoguanine, preferred in the duplex, but not in aqueous solution. The duplexes have relevance to evolution of the modern genetic code and can be used for molecular recognition of natural nucleic acids.

  13. Evaluation of the effects of sildenafil citrate (viagra) on vertebral artery blood flow in patients with vertebro-basilar insufficiency.

    PubMed

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +/- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm(2) to 10.80 cm(2) at 45 minutes and 10.81 cm(2) at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs.

  14. Non-valvular main pulmonary artery vegetation associated with aortopulmonary window.

    PubMed

    Unal, M; Tuncer, C; Serçe, K; Bostan, M; Gökçe, M; Erem, C

    1995-01-01

    We present a 32-year-old female with aortopulmonary window and vegetation of non-valvular main pulmonary artery. The aortopulmonary window is a rare congenital disease in which the aorta and pulmonary arteries are communicated by a defect of variable diameter. The pulmonic valve is the least commonly involved valve in bacterial endocarditis, but there is no vegetation of non-valvular main pulmonary artery in the literature. Colour duplex sonography showed an aortopulmonary window with aortic regurgitation. Magnetic resonance (MR) imaging demonstrating the vegetation on the wall of main pulmonary artery, is an useful and complementary method, and can be used for demonstration of congenital and acquired cardiovascular pathologies including aortopulmonary window and subpulmonic or suprapulmonic vegetations.

  15. A duplex DNA-gold nanoparticle probe composed as a colorimetric biosensor for sequence-specific DNA-binding proteins.

    PubMed

    Ahn, Junho; Choi, Yeonweon; Lee, Ae-Ree; Lee, Joon-Hwa; Jung, Jong Hwa

    2016-03-21

    Using duplex DNA-AuNP aggregates, a sequence-specific DNA-binding protein, SQUAMOSA Promoter-binding-Like protein 12 (SPL-12), was directly determined by SPL-12-duplex DNA interaction-based colorimetric actions of DNA-Au assemblies. In order to prepare duplex DNA-Au aggregates, thiol-modified DNA 1 and DNA 2 were attached onto the surface of AuNPs, respectively, by the salt-aging method and then the DNA-attached AuNPs were mixed. Duplex-DNA-Au aggregates having the average size of 160 nm diameter and the maximum absorption at 529 nm were able to recognize SPL-12 and reached the equivalent state by the addition of ∼30 equivalents of SPL-12 accompanying a color change from red to blue with a red shift of the maximum absorption at 570 nm. As a result, the aggregation size grew to about 247 nm. Also, at higher temperatures of the mixture of duplex-DNA-Au aggregate solution and SPL-12, the equivalent state was reached rapidly. On the contrary, in the control experiment using Bovine Serum Albumin (BSA), no absorption band shift of duplex-DNA-Au aggregates was observed.

  16. Physical-Layer Network Coding for VPN in TDM-PON

    NASA Astrophysics Data System (ADS)

    Wang, Qike; Tse, Kam-Hon; Chen, Lian-Kuan; Liew, Soung-Chang

    2012-12-01

    We experimentally demonstrate a novel optical physical-layer network coding (PNC) scheme over time-division multiplexing (TDM) passive optical network (PON). Full-duplex error-free communications between optical network units (ONUs) at 2.5 Gb/s are shown for all-optical virtual private network (VPN) applications. Compared to the conventional half-duplex communications set-up, our scheme can increase the capacity by 100% with power penalty smaller than 3 dB. Synchronization of two ONUs is not required for the proposed VPN scheme

  17. Ultrasound and color-flow Doppler evaluation for the diagnosis of subclinical hyperthyroidism.

    PubMed

    Cirillo, L; Casella, C; D'Adda, F; Cappelli, C; Salerni, B

    2014-03-01

    Clinical significance, population screening and management of subclinical hyperthyroidism (SHyper) are still debated. Although the diagnosis of subclinical hyperthyroidism is, by definition, purely a biochemical one a conventional gray-scale sonography and, more recently, color-flow Doppler sonography (CFDS) have proven to be useful in obtaining information about thyroid morphology and function in thyroid disease, such as SHyper. The objective of this study was to evaluate, using CFDS, the presence and significance of changes in intrathyroidal blood flow and velocity in patients affected by SHyper and, to evalutate the potential diagnostic role of CFDS in mild thyroid disease in absence of a significant alteration in the serum level of circulating thyroid hormones. In this study, patients with SHyper (the case group) and euthyroid patients (the control group) were enrolled. All patients from the two groups who were affected by multinodular goiter as preoperative diagnosis, underwent total thyroidectomy. In both groups preoperative examination included a conventional grey-scale sonography, followed by CFDS. Quantitative flow evaluation was performed measuring the maximal peak systolic velocity (PSV) at the level of intrathyroid arteries and inferior thyroid artery. Patients with SHyper showed an increased thyroid vascularization both intranodular and peripheral and the mean PSV values were higher in case patients than in control subjects. We have shown that significant changes in thyroid vascularity and blood flow velocity are already present in patients with SHyper. CFDS is a suitable technique to identify SHyper.

  18. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    PubMed Central

    Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    Objective To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). Materials and Methods The study included 21 patients with VBI (aged 31-76; mean 61.0 ± 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Results Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm2 to 10.80 cm2 at 45 minutes and 10.81 cm2 at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Conclusion Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs. PMID:19039262

  19. Variability of mammary blood flow in lactating Holstein-Friesian cows during the first twelve weeks of lactation.

    PubMed

    Götze, A; Honnens, A; Flachowsky, G; Bollwein, H

    2010-01-01

    The goals of the present study were to measure mammary blood flow volume (BFV) during the first 12 wk of lactation in dairy cows by using color Doppler sonography and to determine what affects the mammary blood flow. Forty cows were examined via color Doppler sonography on d 1, 7, 14, 28, 56, and 84 after parturition (d 0). The total BFV (BFV(total)) to the 4 mammary glands was calculated by measuring time-averaged maximum velocities (TAMV) and cross-sectional areas (A) of the left and right pudendoepigastric trunks via transrectal color Doppler sonography. Because there were no significant differences in A, TAMV, and BFV between the right and left pudendoepigastric trunks, the means of A and TAMV, and the BFV(total) of both trunks were used for calculations. The intraindividual and interindividual variability of repeated BFV measures quantified by intraclass correlation coefficients were 96 and 98%, respectively. The BFV(total) ranged from 19.9 to 27.9 L/min, with a mean of 22.3+/-4.9 L/min. Interindividual differences in BFV values were attributable to variations in A and TAMV. The interindividual variability of the BFV(total), which was determined using the coefficients of variation of the BFV(total) on individual days, ranged from 16 to 28%. All the cows had similar changes in the BFV(total) during the study. Changes in BFV(total) were not correlated with changes in the mean of A, but there was a good correlation between changes in BFV(total) and in the mean of TAMV (r=0.94). The BFV(total) was highest on d 1 of lactation, decreased 28% by d 7, and remained at this level until d 28. By d 56, the BFV(total) had increased by 15% compared with d 14 and by 10% compared with d 28. The BFV(total) on d 84 was significantly different from all other days except d 56. There were moderate correlations between daily milk yield and BFV on individual days (0.24

  20. Previously reported sonographic appearances of regional melanoma metastases are not likely due to necrosis.

    PubMed

    Catalano, Orlando; Voit, Christiane; Sandomenico, Fabio; Mandato, Ylenia; Petrillo, Mario; Franco, Renato; Botti, Gerardo; Caracò, Corrado; Mozzillo, Nicola; D'Errico, Adolfo Gallipoli

    2011-08-01

    Sonography has proven to be a reliable tool in early detection of lymph node and in-transit cutaneous-subcutaneous metastases. Those metastases normally appear as hypoechoic or even anechoic lesions on sonography. It has been assumed that this appearance is due to necrosis of the lesions, but so far, that assumption has never been proven. The purpose of this retrospective study was to evaluate whether the hypoechoic appearance of melanoma metastasis is really due to tumor necrosis. From a radiographic database, we retrieved 212 melanoma cases imaged with sonography over a 2-year period for disease staging or follow-up. We selected 37 positive cases with 84 nodal and extranodal (satellite and in-transit) metastatic lesions and reviewed the sonograms and pathologic slides (slides available for 40 of 84 lesions). We retrospectively assessed the vascularization pattern (color Doppler images available for 78 of 84 lesions), categorizing it as poor, intermediate, or consistent. We also looked for necrosis on the histopathologic material, categorizing it into scores of 0, 1, 2, and 3 for absence of necrosis, less than 20% necrosis, 20% to 40% necrosis, and greater than 40% necrosis, respectively. Despite their gray scale appearance, most melanoma lesions were vascularized on color Doppler imaging and showed limited necrosis at histopathologic analysis. Consistent vascularization on Doppler imaging, excluding substantial necrosis, was found in 44 of 78 lesions (56.4%). Poor vascularization on Doppler imaging, suggesting necrosis, was present in only 14% of the lesions. Substantial necrosis (scores of 2 and 3) was found pathologically in only 10% of the lesions. Necrosis seems to be an uncommon event in melanoma metastasis and is probably not the basis for its low-level echo pattern on sonography. The hypoechoic appearance is very typical of melanoma metastasis and is likely due to massive melanomatous infiltration (with the poor echo reflectivity of melanin). However, confirmation in larger pathologically proven series is required.

  1. [Non-palpable testicular tumors in adults: A management based on imaging? Issue from the French Urologic Association Genital Cancer committee's edit].

    PubMed

    Rocher, L; Feretti, L; Camparo, P; Savoie, P H; Morel-Journel, N; Murez, T; Sebe, P; Flechon, A; Méjean, A; Durand, X

    2018-04-09

    Help in management of non-palpable testicular tumors. French Urologic Association Genital cancer committee's Edit. To review their characterization at imaging findings of non-palpable testicular tumors. Literature review (PubMed, Medline) of urological and radiological studies dealing with testicular tumors using keywords: non-palpable/incidental testicular tumors; color Doppler ultrasound; US elastography; magnetic resonance imaging; contrast enhanced sonography; partial surgery. Color Doppler is the basic exam. The size, the presence of microlithts/microlithiasis/macrocalcifications, the vascular architecture are major semiological findings to suggest the benign or the malignant nature of the lesion. Other techniques like multiparametric MRI, contrast-enhanced sonography, sonographic elastography are still in evaluation. The frequency of benign tumors such as Leydig cell tumors lead to preservation management, through improved characterization, monitoring or tumorectomy. Non-randomized study - a very few prospective studies. The era of total orchiectomy for any uncertain testicular lesion is over. We try the challenge of characterization, and define management's algorithms based on the suspected nature of the tumors. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. D-dimer as an applicable test for detection of posttraumatic deep vein thrombosis in lower limb fracture.

    PubMed

    Bakhshi, Hooman; Alavi-Moghaddam, Mostafa; Wu, Karin C; Imami, Mohammad; Banasiri, Mohammad

    2012-06-01

    Measuring the plasma levels of D-dimer is an accurate and easy modality to detect deep vein thrombosis (DVT) in nontraumatic settings. However, the diagnostic reliability of D-dimer assays in detecting posttraumatic DVT among patients with lower limb fracture undergoing orthopedic surgery is not validated. In this study, 141 patients with lower limb fracture admitted through the emergency department and undergoing orthopedic surgery were enrolled. Postoperative venous blood samples for D-dimer assay were taken on the 1st, 7th, and 28th postoperative days. Color Doppler sonography examination of both lower limbs was performed at the same time as a standard test. Eight out of the 141 patients (6%) had acute DVT based on Color Doppler sonography. Mean D-dimer was 2160 ng/mL in DVT positive patients and 864 in DVT negative patients. D-dimer levels greater than 1000 ng/mL were 100% sensitive and 71% specific for detecting postoperative DVT. D-dimer assay is a useful and sensitive test for detecting posttraumatic DVT.

  3. Three-dimensional high-definition flow in the diagnosis of placental lakes.

    PubMed

    Inubashiri, Eisuke; Deguchi, Keizou; Abe, Kiyotaka; Saitou, Atushi; Watanabe, Yukio; Akutagawa, Noriyuki; Kuroki, Katumaru; Sugawara, Masaki; Maeda, Nobuhiko

    2014-10-01

    Placental lakes are sonolucent areas often found in the normal placenta. Most of them are asymptomatic. They are sometimes related to placenta accreta or intrauterine fetal growth restriction, among other conditions. Although Doppler sonography is useful for evaluating noxious placental lakes, it is not easy to adapt Doppler studies to conventional two-dimensional color Doppler sonography because of the low-velocity blood flow and high vascularity in the placenta. Here, we demonstrate how three-dimensional high-definition imaging of flow provides a novel visual depiction of placental lakes, which helps substantially with the differential diagnosis. As far as we know, there have been no previous reports of observation of placental lakes using three-dimensional high-definition imaging of flow.

  4. [Acute right-sided upper abdominal pain in a 46-year-old woman].

    PubMed

    Bauder, M; Fiala, A; Klinger, C; Kersjes, W; Caca, K

    2018-02-01

    A 46-year-old woman presented with acute abdominal pain in the right upper quadrant. Esophagogastroduodenoscopy revealed a duodenal stenosis within the horizontal part of the duodenum. Based on the findings of abdominal computed tomography (CT), endosonography, Doppler duplex sonography and angiography, the diagnosis of an aneurysm of a branch of the inferior pancreaticoduodenal artery was established. This arterial branch was part of a collateral circulation between the superior mesenteric artery and the proper hepatic artery caused by obturation of the celiac artery. The symptomatic duodenal stenosis was the result of a local hematoma due to prior rupture of an aneurysm. After successful coiling of the afferent vessels to the aneurysm follow-up examinations showed progredient resorption of the hematoma and the patient was free of complaints.

  5. Acute appendicitis-like symptoms as initial presentation of ovarian vein thrombosis.

    PubMed

    Prieto-Nieto, M I; Perez-Robledo, J P; Rodriguez-Montes, J A; Garci-Sancho-Martin, L

    2004-07-01

    Postpartum ovarian vein thrombosis is a rare condition, with an incidence rate being 1/600 deliveries. It most often arises in the right ovarian vein. A 33-year-old patient who had had normal vaginal delivery presented with fever, pain in the right iliac fossa, and leukocytosis on the sixth day after delivery. An antibiotic course was instituted but 3 days later symptoms reappeared. Diagnosis of acute appendicitis was made. At surgery through a McBurney incision, a woody tumoration consistent with ovarian vein thrombosis was found. Anticoagulation therapy with heparin and antibiotics were instituted. Phlebography and color Doppler sonography confirmed the presence of thrombosis of both the common femoral iliac and inferior vena cava. Fribrolysis with urokinase was performed. The patient has remained stable and symptom-free over a 4-year follow-up. Ovarian vein thrombosis typically presents with symptoms suggestive of acute appendicitis, as was the case in our patient. Color Doppler sonography is the favored diagnostic procedure, with CT being a supplementary tool. Surgery is not necessary and treatment consists of anticoagulants and antibiotics. Even though postpartum ovarian vein thrombosis is rare, early recognition of the condition is of paramount importance to institute the adequate treatment and avoid potential serious sequelae.

  6. Analysis of focal spared areas in fatty liver using color Doppler imaging and contrast-enhanced microvessel display sonography.

    PubMed

    Liu, Li-Ping; Dong, Bao-Wei; Yu, Xiao-Ling; Zhang, Da-Kun; Li, Xin; Li, Hua

    2008-03-01

    The purpose of this study was to investigate whether focal fatty sparing (FFS) formation in the liver relates to aberrant blood flow. Sixty-three FFSs of the liver in 52 patients were examined by color Doppler flow imaging and contrast-enhanced microvessel display sonography. The 63 FFSs included 16 FFSs in the porta hepatis, 14 FFSs around the gallbladder fossa, and 33 other FFSs. The control group included patients with a diagnosis of fatty liver but no FFSs or focal lesions near the porta hepatis. Fourteen of 16 FFSs in the porta hepatis showed venous blood toward those areas that were differentiated from the portal and hepatic veins. Focal fatty sparings in the hilus hepatis correlated with aberrant veins, having a statistical significance compared with the control group (P < .0001). Seven of 14 FFSs around the gallbladder fossa contained blood vessels, 5 of them veins and the remaining 2 arteries. Two FFSs were located around hemangiomas. Three FFSs were located around maldeveloped vessels. The blood supply to an FFS in the porta hepatis may be correlated with aberrant veins. Focal fatty sparings around the gallbladder fossa may be associated with aberrant blood flow.

  7. Clinical impact and predictors of carotid artery in-stent restenosis.

    PubMed

    Wasser, Katrin; Schnaudigel, Sonja; Wohlfahrt, Janin; Psychogios, Marios-Nikos; Schramm, Peter; Knauth, Michael; Gröschel, Klaus

    2012-09-01

    To assess the incidence and clinical significance as well as predictors of in-stent restenosis (ISR) after carotid artery stenting (CAS) diagnosed with serial duplex sonography investigations. We analyzed 215 CAS procedures that had clinical and serial carotid duplex ultrasound investigations. The incidence of in-stent restenosis (ISR) and periprocedural as well as long-term clinical complications were recorded. The influence of an ISR on clinical complication was analyzed using Kaplan-Meier curves and clinical risk factors for the development of an ISR with multivariate logistic regression. During a median follow-up time of 33.4 months (interquartile range 15.3-53.7) an ISR of ≥70% was detected in 12 (6.1%) of 215 arteries (mean age of 68.1 ± 9.8 years, 71.6% male). The combined stroke and death rate during long-term follow-up was significantly higher in the group with an ISR [odds ratio (OR): 3.59, 95% confidence interval (CI): 1.50-8.59, p = 0.004]. After applying multivariate logistic regression analysis contralateral carotid occlusion (OR 10.11, 95% CI 2.06-49.63, p = 0.004), carotid endarterectomy (CEA) restenosis (OR 8.87, 95% CI 1.68-46.84, p = 0.010) and postprocedural carotid duplex ultrasound with a PSV ≥120 cm/s (OR 6.33, 95% CI 1.27-31.44, p = 0.024) were independent predictors of ISR. ISR after CAS during long-term follow-up is associated with a higher proportion of clinical complications. A close follow-up is suggested especially in those patients with the aforementioned independent predictors of an ISR. Against the background of a lacking established treatment of ISR, these findings should be taken into account when offering CAS as a treatment alternative to CEA.

  8. The influence of Sildenafil citrate on uterine tissue perfusion and the cardiovascular system during the luteal phase of the ovarian cycle in cows.

    PubMed

    Dzięcioł, Michał; Stańczyk, Ewa; Noszczyk-Nowak, Agnieszka; Michlik, Katarzyna; Kozdrowski, Roland; Niżański, Wojciech; Pasławskab, Urszula; Mrowiec, Jacek; Twardoń, Jan

    2014-03-01

    The aim of the study was to evaluate the influence of the Sildenafil citrate on the blood flow in the uterus of cows during dioestrus. Uterine blood flow was examined in five, healthy, adult cows. Between day 6-8 of the ovarian cycle, each cow received 200mg of sildenafil diluted in 10ml of warm saline into the body of the uterus. Analysis of the blood pressure, ECG and the maximum velocity in m/s (V max) in the aorta was performed and selected parameters of the blood flow (PI, pulsatile index; RI, resistance index; SPV, systolic peak velocity; EDV, end diastolic velocity; FVI, flow velocity integral; SV/DV, systolic peak velocity: end-diastolic velocity ratio) were measured in the uterine artery (Arteria uterine) before and after sildenafil infusion. In addition, Color Doppler examination of the uterine wall perfusion was analyzed. A significant decrease of values of PI and SV/DV ratio as well as an increase of end diastolic velocity and time averaged maximum velocity was noted. With the use of color coded sonography, the increased intensity of the blood flow in the uterine wall was observed. It was concluded that intrauterine administration of sildenafil during dioestrus can increase uterine tissue perfusion. Copyright © 2013 Elsevier GmbH. All rights reserved.

  9. Duplex sonography for detection of deep vein thrombosis of upper extremities: a 13-year experience.

    PubMed

    Chung, Amy S Y; Luk, W H; Lo, Adrian X N; Lo, C F

    2015-04-01

    To determine the prevalence and characteristics of sonographically evident upper-extremity deep vein thrombosis in symptomatic Chinese patients and identify its associated risk factors. Regional hospital, Hong Kong. Data on patients undergoing upper-extremity venous sonography examinations during a 13-year period from November 1999 to October 2012 were retrieved. Variables including age, sex, history of smoking, history of lower-extremity deep vein thrombosis, major surgery within 30 days, immobilisation within 30 days, cancer (history of malignancy), associated central venous or indwelling catheter, hypertension, diabetes mellitus, sepsis within 30 days, and stroke within 30 days were tested using binary logistic regression to understand the risk factors for upper-extremity deep vein thrombosis. The presence of upper-extremity deep vein thrombosis identified. Overall, 213 patients with upper-extremity sonography were identified. Of these patients, 29 (13.6%) had upper-extremity deep vein thrombosis. The proportion of upper-extremity deep vein thrombosis using initial ultrasound was 0.26% of all deep vein thrombosis ultrasound requests. Upper limb swelling was the most common presentation seen in a total of 206 (96.7%) patients. Smoking (37.9%), history of cancer (65.5%), and hypertension (27.6%) were the more prevalent conditions among patients in the upper-extremity deep vein thrombosis-positive group. No statistically significant predictor of upper-extremity deep vein thrombosis was noted if all variables were included. After backward stepwise logistic regression, the final model was left with only age (P=0.119), female gender (P=0.114), and history of malignancy (P=0.024) as independent variables. History of malignancy remained predictive of upper-extremity deep vein thrombosis. Upper-extremity deep vein thrombosis is uncommon among symptomatic Chinese population. The most common sign is swelling and the major risk factor for upper-extremity deep vein thrombosis identified in this study is malignancy.

  10. All-optical OFDM network coding scheme for all-optical virtual private communication in PON

    NASA Astrophysics Data System (ADS)

    Li, Lijun; Gu, Rentao; Ji, Yuefeng; Bai, Lin; Huang, Zhitong

    2014-03-01

    A novel optical orthogonal frequency division multiplexing (OFDM) network coding scheme is proposed over passive optical network (PON) system. The proposed scheme for all-optical virtual private network (VPN) does not only improve transmission efficiency, but also realize full-duplex communication mode in a single fiber. Compared with the traditional all-optical VPN architectures, the all-optical OFDM network coding scheme can support higher speed, more flexible bandwidth allocation, and higher spectrum efficiency. In order to reduce the difficulty of alignment for encoding operation between inter-communication traffic, the width of OFDM subcarrier pulse is stretched in our proposed scheme. The feasibility of all-optical OFDM network coding scheme for VPN is verified, and the relevant simulation results show that the full-duplex inter-communication traffic stream can be transmitted successfully. Furthermore, the tolerance of misalignment existing in inter-ONUs traffic is investigated and analyzed for all-optical encoding operation, and the difficulty of pulse alignment is proved to be lower.

  11. 76 FR 64924 - Updating State Residential Building Energy Efficiency Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ...) considers high-rise (greater than three stories) multifamily residential buildings and hotel, motel, and..., duplexes, townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such... pumps as compared to other electric heating technologies, this code change is expected to increase the...

  12. Noninvasive assessment of normal carotid bifurcation hemodynamics with color-flow ultrasound imaging.

    PubMed

    Zierler, R E; Phillips, D J; Beach, K W; Primozich, J F; Strandness, D E

    1987-08-01

    The combination of a B-mode imaging system and a single range-gate pulsed Doppler flow velocity detector (duplex scanner) has become the standard noninvasive method for assessing the extracranial carotid artery. However, a significant limitation of this approach is the small area of vessel lumen that can be evaluated at any one time. This report describes a new duplex instrument that displays blood flow as colors superimposed on a real-time B-mode image. Returning echoes from a linear array of transducers are continuously processed for amplitude and phase. Changes in phase are produced by tissue motion and are used to calculate Doppler shift frequency. This results in a color assignment: red and blue indicate direction of flow with respect to the ultrasound beam, and lighter shades represent higher velocities. The carotid bifurcations of 10 normal subjects were studied. Changes in flow velocities across the arterial lumen were clearly visualized as varying shades of red or blue during the cardiac cycle. A region of flow separation was observed in all proximal internal carotids as a blue area located along the outer wall of the bulb. Thus, it is possible to detect the localized flow patterns that characterize normal carotid arteries. Other advantages of color-flow imaging include the ability to rapidly identify the carotid bifurcation branches and any associated anatomic variations.

  13. Three-Dimensional Virtual Sonographic Cystoscopy for Detection of Ureterocele in Duplicated Collecting Systems in Children.

    PubMed

    Nabavizadeh, Behnam; Mozafarpour, Sarah; Hosseini Sharifi, Seyed Hossein; Nabavizadeh, Reza; Abbasioun, Reza; Kajbafzadeh, Abdol-Mohammad

    2018-03-01

    Ureterocele is a sac-like dilatation of terminal ureter. Precise anatomic delineation is of utmost importance to proceed with the surgical plan, particularly in the ectopic subtype. However, the level of ureterocele extension is not always elucidated by the existing imaging modalities and even by conventional cystoscopy, which is considered as the gold standard for evaluation of ureterocele. This study aims to evaluate the accuracy of three-dimensional virtual sonographic cystoscopy (VSC) in the characterization of ureterocele in duplex collecting systems. Sixteen children with a mean age of 5.1 (standard deviation 1.96) years with transabdominal ultrasonography-proven duplex system and ureterocele were included. They underwent VSC by a single pediatric radiologist. All of them subsequently had conventional cystoscopy, and the results were compared in terms of ureterocele features including anatomy, number, size, location, and extension. Three-dimensional VSC was well tolerated in all cases without any complication. Image quality was suboptimal in 2 of 16 patients. Out of the remaining 14 cases, VSC had a high accuracy in characterization of the ureterocele features (93%). Only the extension of one ureterocele was not precisely detected by VSC. The results of this study suggest three-dimensional sonography as a promising noninvasive diagnostic modality in the evaluation of ectopic ureterocele in children. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Percutaneous trans-hepatic gelfoam-cyanoacrylate glue embolization for ruptured post-traumatic hepatic artery pseudo-aneurysm in a limited-resource scenario.

    PubMed

    Kumar, Manoj; Goel, Prabudh; Rawat, J D; Kumari, Shweta; Shankhwar, S N; Kureel, S N

    2013-05-01

    We present our experience with an indigenously designed percutaneous trans-hepatic ultrasound-guided Gelfoam sponge cum cyanoacrylate glue-based embolization technique for the treatment of a ruptured post-traumatic aneurysm of a branch of the right hepatic artery (RHA) as a 'life-saving emergent' procedure in a patient unfit for surgery or endovascular intervention and in a 'limited-resource' scenario (non-availability of Digital Subtraction Angiography Suite). An 8-year-old boy sustained crush-injury to the right lobe of the liver in a road-traffic accident and presented in shock. After resuscitation, a laparotomy and repair of the right lobe of liver were undertaken. Bleeding restarted 1 week after the surgery; the patient bled from drain site and went into shock. Exploration was not advisable in view of poor general condition, and sepsis, deranged coagulation and parental reluctance in view of guarded prognosis. Multi-detector Computed Tomography Angiography was performed after resuscitation which revealed active bleed from a ruptured pseudo-aneurysm of a branch of RHA. The bleeding artery was identified with duplex sonography and was embolized by the percutaneous trans-hepatic route proximal to the site of pseudo-aneurysm and rupture by a two-step process. Initially, a thin paste/'slurry' made of powdered gelfoam dissolved in sterile saline was injected into the bleeding vessel. Subsequently, the area was sealed by injecting 1.0 ml of N-butyl-2-cyanoacrylate glue. Hemostasis was confirmed by Color and Power Doppler Ultrasonography both post-procedure and after 48 h. With supportive management, the patient showed a rapid recovery and was discharged after 2 weeks. He continues to be well at 3-month follow-up. The technique was effective in controlling hemostasis and life-saving in our set-up.

  15. Ultrasonography of Skin Changes in Legs with Chronic Venous Disease.

    PubMed

    Caggiati, A

    2016-10-01

    In daily practice, ultrasonography (US) is used only to designate the location and pattern of venous lesions. Skin US is not performed between routine venous investigations. Skin morphology is evaluated by the same probes used for routine Duplex evaluation of superficial veins. US findings from evident skin lesions are comparatively evaluated with those from the surrounding apparently normal skin and from the contralateral leg. Inflammation and dermal edema can be found in the apparently normal skin of C2 legs. Swollen legs show thickening of the subcutaneous layer as a result of diffuse soaking or anechoic cavities, with or without dermal edema. Chronic hypodermitis is characterized by inflammatory edema in initial phases, and by liposclerosis in advanced cases. Recrudescence of inflammation provokes focal rarefactions of the subcutaneous layer, possibly related to ulcer opening. In legs with venous disorders, sonography refines clinical evaluation of the skin and may reveal changes not highlighted by inspection. Some of these changes could require further investigation because they have not yet been explained or described. Skin sonography should improve knowledge of the natural history of skin changes, as well as contribute to a better grading of venous diseases severity In particular, US evidence of cutaneous and subcutaneous changes in C2 legs should be considered to stratify the treatment in C2 legs, by identifying those in which varicose veins are not simply a cosmetic problem. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    PubMed Central

    Landgraeber, Stefan; Albrecht, Thomas; Reischuck, Ulrich; von Knoch, Marius

    2012-01-01

    We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yielded no pathological findings. Overnight the neurological deficits decreased without therapy and were finally no longer detectable. We speculate that during the administration of the local anaesthetic a depot formed, localised in the medial femoral intermuscular septa, which was leaked after first mobilisation. To our knowledge no similar case has been published up to now. We conclude that patients who are treated with a nerve block should be informed and physician should be aware that delayed neurological deficits are possible. PMID:22577509

  17. DNA octaplex formation with an I-motif of water-mediated A-quartets: reinterpretation of the crystal structure of d(GCGAAAGC).

    PubMed

    Sato, Yoshiteru; Mitomi, Kenta; Sunami, Tomoko; Kondo, Jiro; Takénaka, Akio

    2006-12-01

    The crystal structure of the tetragonal form of d(gcGAAAgc) has been revised and reasonably refined including the disordered residues. The two DNA strands form a base-intercalated duplex, and the four duplexes are assembled according to the crystallographic 222 symmetry to form an octaplex. In the central region, the eight strands are associated by I-motif of double A-quartets. Furthermore, eight hydrated-magnesium cations link the four duplexes to support the octaplex formation. Based on these structural features, a proposal that folding of d(GAAA)n, found in the non-coding region of genomes, into an octaplex can induce slippage during replication to facilitate length polymorphism is presented.

  18. An Eye-Tracking Study of How Color Coding Affects Multimedia Learning

    ERIC Educational Resources Information Center

    Ozcelik, Erol; Karakus, Turkan; Kursun, Engin; Cagiltay, Kursat

    2009-01-01

    Color coding has been proposed to promote more effective learning. However, insufficient evidence currently exists to show how color coding leads to better learning. The goal of this study was to investigate the underlying cause of the color coding effect by utilizing eye movement data. Fifty-two participants studied either a color-coded or…

  19. New t-gap insertion-deletion-like metrics for DNA hybridization thermodynamic modeling.

    PubMed

    D'yachkov, Arkadii G; Macula, Anthony J; Pogozelski, Wendy K; Renz, Thomas E; Rykov, Vyacheslav V; Torney, David C

    2006-05-01

    We discuss the concept of t-gap block isomorphic subsequences and use it to describe new abstract string metrics that are similar to the Levenshtein insertion-deletion metric. Some of the metrics that we define can be used to model a thermodynamic distance function on single-stranded DNA sequences. Our model captures a key aspect of the nearest neighbor thermodynamic model for hybridized DNA duplexes. One version of our metric gives the maximum number of stacked pairs of hydrogen bonded nucleotide base pairs that can be present in any secondary structure in a hybridized DNA duplex without pseudoknots. Thermodynamic distance functions are important components in the construction of DNA codes, and DNA codes are important components in biomolecular computing, nanotechnology, and other biotechnical applications that employ DNA hybridization assays. We show how our new distances can be calculated by using a dynamic programming method, and we derive a Varshamov-Gilbert-like lower bound on the size of some of codes using these distance functions as constraints. We also discuss software implementation of our DNA code design methods.

  20. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    PubMed

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged <60 years and 18 (43/9%) patients were aged >60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  1. Spatial transform coding of color images.

    NASA Technical Reports Server (NTRS)

    Pratt, W. K.

    1971-01-01

    The application of the transform-coding concept to the coding of color images represented by three primary color planes of data is discussed. The principles of spatial transform coding are reviewed and the merits of various methods of color-image representation are examined. A performance analysis is presented for the color-image transform-coding system. Results of a computer simulation of the coding system are also given. It is shown that, by transform coding, the chrominance content of a color image can be coded with an average of 1.0 bits per element or less without serious degradation. If luminance coding is also employed, the average rate reduces to about 2.0 bits per element or less.

  2. The use of contrasted transvaginal sonography in the diagnosis of gynecologic diseases: a preliminary study.

    PubMed

    Testa, Antonia Carla; Ferrandina, Gabriella; Fruscella, Erika; Van Holsbeke, Caroline; Ferrazzi, Enrico; Leone, Francesco P G; Arduini, Domenico; Exacoustos, Caterina; Bokor, Daniela; Scambia, Giovanni; Timmerman, Dirk

    2005-09-01

    The purpose of this study was to evaluate the efficacy of a new contrast-dedicated ultrasound technology, contrast-tuned imaging (CnTI), implemented on an endovaginal probe and using the second-generation contrast agent SonoVue (Bracco International BV, Amsterdam, the Netherlands), compared with the standard ultrasound examination in different gynecologic diseases. Eighty-nine patients were enrolled in the study in 4 different clinical centers. The study included 40 patients with uncertain pelvic adnexal masses, 10 patients with pelvic masses indicative of recurrences of gynecologic tumors, 26 patients with uterine pathologic features, and 13 patients with cervical lesions. Application of CnTI technology after the SonoVue injection gave a picture of the intralesional microvascularization dramatically different from that obtained during color Doppler examination. Of the 40 pelvic masses, 15 (37.5%) were considered benign and 25 (62.5%) were considered malignant at B-mode and color Doppler examinations. Contrast-enhanced sonography showed no intralesional contrast perfusion in 11 (73%) of 15 cases, and all these were benign at final diagnosis. Of the 4 (27%) cases that had perfusion, 2 were malignant. Conversely, of the 25 cases with positive findings at color Doppler examination and therefore expected to show the appearance of contrast tissue-filling morphologic characteristics, 13 (52%) were malignant at final diagnosis. For evaluation of uterine pathologic features, the CnTI-SonoVue technology did not appear to be superior to the B-mode and color Doppler examinations; however, for the evaluation of cervical cancer, CnTI-SonoVue technology revealed a better definition of the margins of the neoplastic lesions in 4 (40%) of 10 cases. In the evaluation of uncertain pelvic masses, the CnTI technology led to an improvement in the ability of the practitioner to differentiate benign from malignant adnexal lesions.

  3. Vascular Pattern Analysis on Microvascular Sonography for Differentiation of Pleomorphic Adenomas and Warthin Tumors of Salivary Glands.

    PubMed

    Ryoo, Inseon; Suh, Sangil; Lee, Young Hen; Seo, Hyung Suk; Seol, Hae Young; Woo, Jeong-Soo; Kim, Soo Chin

    2018-03-01

    Pleomorphic adenomas and Warthin tumors are the most common salivary gland tumors. It is important to differentiate between them because at least a partial parotidectomy is necessary for pleomorphic adenomas, whereas enucleation is sufficient for Warthin tumors. This study aimed to evaluate the usefulness of vascular pattern analysis using microvascular sonography to differentiate between the tumors. Sixty-two patients with pathologically proven pleomorphic adenomas (n = 38) and Warthin tumors (n = 24) were included. For all tumors, grayscale, power Doppler, and microvascular sonographic examinations were performed. Differences in vascular patterns (vascular distribution and internal vascularity) on power Doppler and microvascular sonography as well as grayscale sonographic features (size, shape, border, echogenicity, heterogeneity, and cystic change) between pleomorphic adenomas and Warthin tumors were evaluated. A comparison of diagnostic performances of grayscale sonography with power Doppler sonography and grayscale sonography with microvascular sonography was performed. The level of interobserver agreement between 2 reviewers in diagnosing tumors was evaluated. No grayscale sonographic features showed a significant difference between the tumors. Vascular distributions and internal vascularity on power Doppler sonography (P = .01 and .002) and microvascular sonography (both P < .001) were all significantly different. The diagnostic accuracy of grayscale sonography with microvascular sonography (79.0%) was higher than that of grayscale sonography with power Doppler sonography (72.6%). This difference was significant according to the McNemar test (P = .004). Interobserver agreement was excellent in diagnosing tumors on both grayscale sonography with power Doppler sonography (κ = 0.83) and grayscale sonography with microvascular sonography (κ = 0.94). Vascular pattern analysis using microvascular sonography with other sonographic features is helpful for differentiating between pleomorphic adenomas and Warthin tumors. © 2017 by the American Institute of Ultrasound in Medicine.

  4. Partial nephrectomy for small children: Robot-assisted versus open surgery.

    PubMed

    Ballouhey, Quentin; Binet, Aurélien; Clermidi, Pauline; Braik, Karim; Villemagne, Thierry; Cros, Jérôme; Lardy, Hubert; Fourcade, Laurent

    2017-12-01

    To compare the outcomes of robot-assisted heminephrectomy for duplex kidney in children with those of open heminephrectomy. The present retrospective multicentric analysis reviewed the records of robot-assisted versus open heminephrectomy carried out for duplex kidney in children from 2007 to 2014. Demographic data, weight, surgical time, hospital stay, complications and outcome were recorded. Follow up was based on a clinical review, renal sonography and dimercaptosuccinic acid renal scintigraphy. A total of 15 patients underwent robot-assisted heminephrectomy, and 13 patients underwent retroperitoneal heminephrectomy by open approach. All patients weighed <15 kg. The mean age at the time of surgery was 20.2 months (range 7-39 months) in the robotic group, and 18.4 months (range 6-41 months) in the open group. The mean hospital stay was statistically longer for the open surgery group (6.3 days, range 5-8 days vs 3.4 days, range 1-7 days; P < 0.001). Regarding postoperative pain control, total morphine equivalent intake was statistically greater for the open group (0.52 mg/kg/day vs 1.08 mg/kg/day; P < 0.001). No patient lost the remaining healthy moiety. There was no significant difference in terms of operating time, complication rate or renal outcomes. Robot-assisted heminephrectomy in small children seems to offer comparable renal outcomes with those of its standard open surgery counterpart. Specific technical adjustments are necessary, which typically increase the set-up time. © 2017 The Japanese Urological Association.

  5. Pelvic Vein Embolisation in the Management of Varicose Veins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratnam, Lakshmi A.; Marsh, Petra; Holdstock, Judy M.

    2008-11-15

    Pelvic vein incompetence is common in patients with atypical varicose veins, contributing to their recurrence after surgery. Therefore, refluxing pelvic veins should be identified and treated. We present our experience with pelvic vein embolisation in patients presenting with varicose veins. Patients presenting with varicose veins with a duplex-proven contribution from perivulval veins undergo transvaginal duplex sonography (TVUS) to identify refluxing pelvic veins. Those with positive scans undergo embolisation before surgical treatment of their lower limb varicose veins. A total of 218 women (mean age of 46.3 years) were treated. Parity was documented in the first 60 patients, of whom 47more » (78.3%) were multiparous, 11 (18.3%) had had one previous pregnancy, and 2 (3.3%) were nulliparous. The left ovarian vein was embolised in 78%, the right internal iliac in 64.7%, the left internal iliac in 56.4%, and the right ovarian vein in 42.2% of patients. At follow-up TVUS, mild reflux only was seen in 16, marked persistent reflux in 6, and new reflux in 3 patients. These 9 women underwent successful repeat embolisation. Two patients experienced pulmonary embolisation of the coils, of whom 1 was asymptomatic and 1 was successfully retrieved; 1 patient had a misplaced coil protruding into the common femoral vein; and 1 patient had perineal thrombophlebitis. The results of our study showed that pelvic venous embolisation by way of a transjugular approach is a safe and effective technique in the treatment of pelvic vein reflux.« less

  6. A fault-tolerant information processing concept for space vehicles.

    NASA Technical Reports Server (NTRS)

    Hopkins, A. L., Jr.

    1971-01-01

    A distributed fault-tolerant information processing system is proposed, comprising a central multiprocessor, dedicated local processors, and multiplexed input-output buses connecting them together. The processors in the multiprocessor are duplicated for error detection, which is felt to be less expensive than using coded redundancy of comparable effectiveness. Error recovery is made possible by a triplicated scratchpad memory in each processor. The main multiprocessor memory uses replicated memory for error detection and correction. Local processors use any of three conventional redundancy techniques: voting, duplex pairs with backup, and duplex pairs in independent subsystems.

  7. Molecular dynamics study of some non-hydrogen-bonding base pair DNA strands

    NASA Astrophysics Data System (ADS)

    Tiwari, Rakesh K.; Ojha, Rajendra P.; Tiwari, Gargi; Pandey, Vishnudatt; Mall, Vijaysree

    2018-05-01

    In order to elucidate the structural activity of hydrophobic modified DNA, the DMMO2-D5SICS, base pair is introduced as a constituent in different set of 12-mer and 14-mer DNA sequences for the molecular dynamics (MD) simulation in explicit water solvent. AMBER 14 force field was employed for each set of duplex during the 200ns production-dynamics simulation in orthogonal-box-water solvent by the Particle-Mesh-Ewald (PME) method in infinite periodic boundary conditions (PBC) to determine conformational parameters of the complex. The force-field parameters of modified base-pair were calculated by Gaussian-code using Hartree-Fock /ab-initio methodology. RMSD Results reveal that the conformation of the duplex is sequence dependent and the binding energy of the complex depends on the position of the modified base-pair in the nucleic acid strand. We found that non-bonding energy had a significant contribution to stabilising such type of duplex in comparison to electrostatic energy. The distortion produced within strands by such type of base-pair was local and destabilised the duplex integrity near to substitution, moreover the binding energy of duplex depends on the position of substitution of hydrophobic base-pair and the DNA sequence and strongly supports the corresponding experimental study.

  8. Real-time compound sonography of the rotator-cuff: evaluation of artefact reduction and image definition.

    PubMed

    De Candia, Alessandro; Doratiotto, Stefsano; Paschina, Elio; Segatto, Enrica; Pelizzo, Francesco; Bazzocchi, Massimo

    2003-04-01

    The aim of this study was to compare real time compound sonography with conventional sonography in the evaluation of rotator cuff tears. A prospective study was performed on 50 supraspinatus tendons in 101 patients treated by surgical acromioplasty. The surgeon described 33 (66%) full-thickness tears and 17 (34%) partial-thickness tears. All tendons were examined by conventional sonography and real time compound sonography on the day before surgery. The techniques were compared by evaluating the images for freedom from artefacts, contrast resolution and overall image definition. Real time compound sonography proved to be superior to conventional sonography as regards freedom from artefacts in 50 cases out of 50 (100%). It was superior to conventional sonography in evaluating the image contrast resolution in 45 cases out of 50 (90%), and superior to conventional sonography in overall image definition in 45 out of 50 cases (90%). Real-time compound sonography reduces the intrinsic artefacts of conventional sonography and allows better overall image definition. In particular, the digital technique allowed us to study the rotator cuff with better contrast resolution and sharper and more detailed images than did conventional sonography.

  9. Effect of Color-Coded Notation on Music Achievement of Elementary Instrumental Students.

    ERIC Educational Resources Information Center

    Rogers, George L.

    1991-01-01

    Presents results of a study of color-coded notation to teach music reading to instrumental students. Finds no clear evidence that color-coded notation enhances achievement on performing by memory, sight-reading, or note naming. Suggests that some students depended on the color-coding and were unable to read uncolored notation well. (DK)

  10. 29 CFR 1910.144 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 5 2013-07-01 2013-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...

  11. 29 CFR 1910.144 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 5 2014-07-01 2014-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...

  12. 29 CFR 1910.144 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 5 2012-07-01 2012-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...

  13. 29 CFR 1910.144 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be... basic color for designating caution and for marking physical hazards such as: Striking against...

  14. Prospective Comparison of Magnetic Resonance Imaging, Transrectal and Transperineal Sonography, and Surgical Findings in Complicated Perianal Crohn Disease.

    PubMed

    Bor, Renáta; Farkas, Klaudia; Bálint, Anita; Szűcs, Mónika; Ábrahám, Szabolcs; Milassin, Ágnes; Rutka, Mariann; Nagy, Ferenc; Milassin, Péter; Szepes, Zoltán; Molnár, Tamás

    2016-11-01

    Magnetic resonance imaging (MRI) and transrectal sonography are the two accepted imaging modalities for evaluation of perianal fistulas and abscesses. Transperineal sonography is a new technique that is easy to learn and can be performed at any time. The purpose of this study was to prospectively compare the diagnostic accuracy of MRI, transrectal sonography, and transperineal sonography with surgical findings in patients with perianal Crohn disease. All patients with perianal Crohn disease underwent MRI, transrectal sonography, and transperineal sonography within a few days before surgery. Fistulas were classified as simple (43.8%) or complex (52.2%) based on surgical findings. Twenty-three patients with active perianal Crohn disease (12 women and 11 men; mean age, 29.9 years; current therapy: antibiotics, 69.6%; azathioprine, 56.5%; and biologics, 73.9%; previous surgery, 26.1%; and proportion of smokers, 39.1%) were included. Sensitivity values for MRI, transrectal sonography, and transperineal sonography for diagnosis of fistulas were 84.6%, 84.6%, and 100%, respectively. Transperineal sonography was more sensitive for diagnosis of perianal abscesses than MRI and transrectal sonography (100%, 58.8%, and 92.8%). Transperineal sonography is a very accurate diagnostic method with outstanding sensitivity compared with MRI and transrectal sonography for evaluation of complicated perianal Crohn disease. Due to its simplicity and low cost, it is recommended that transperineal sonography be the first diagnostic modality in these cases. © 2016 by the American Institute of Ultrasound in Medicine.

  15. Color flow Doppler sonography for the etiologic diagnosis of thyrotoxicosis.

    PubMed

    Rosario, P W; Santos, J B N; Nunes, N S; da Silva, A L; Calsolari, M R

    2014-06-01

    The objective of this prospective study was to compare the results of color flow Doppler sonography (CFDS) and radioiodine scintigraphy in patients with thyrotoxicosis. A total of 176 patients, 102 with clinical thyrotoxicosis and 74 with subclinical dysfunction, were included. Pregnant and breast-feeding women, patients using amiodarone or recently exposed to iodinated contrast, and patients treated with antithyroid drugs were excluded. Total T3, free T4, TSH, and anti-TSH receptor antibodies were measured before scintigraphy and CFDS. Excluding one patient whose etiology of thyrotoxicosis remained undefined, CFDS showed 100% specificity. In fact, in all 10 cases in which scintigraphy and CFDS provided discordant results, the diagnosis suggested by the latter was correct. In patients with clinical thyrotoxicosis, the sensitivity of CFDS was 96% for diffuse toxic goiter, 95% for the absence of hyperfunction, and 100% for toxic nodular disease. In patients with subclinical dysfunction, the sensitivity of CFDS was 72.7% for diffuse toxic goiter, 90% for toxic adenoma, and 86.6% for toxic multinodular disease. CFDS was inconclusive in patients with parenchymal blood flow with patchy uneven distribution or with macronodules in which nodule vascularity compared to the remaining parenchyma did not permit to establish the diagnosis with certainty. CFDS can be used instead of scintigraphy not only in situations in which the latter is contraindicated or of limited value to define the etiology of thyrotoxicosis. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Patients with chronic kidney disease: safety aspects in the preoperative management.

    PubMed

    Malovrh, Marko

    2015-01-01

    Chronic kidney disease (CKD) is a major public health problem worldwide. Early detection and treatment of CKD can often prevent or delay some of the negative outcomes of CKD. This chapter shows how treatment of hypertension, proteinuria and metabolic disorders slow down the deterioration of renal function. Irrespective of the mode of renal replacement therapy, maintaining the veins in the upper extremities is of vital importance. Below are suggestions on how to protect blood vessels of the upper limbs and when to start preparing for the construction of vascular access. In this chapter, it is also shown how necessary it is to conduct a clinical evaluation of the blood vessels, which is required before the start of vascular access management. The methodology of noninvasive evaluation of vessels by duplex sonography is also presented. This method is very useful, especially if the vessels are not clinically visible, as well as the information concerning the morphological and functional properties of blood vessels. © 2015 S. Karger AG, Basel

  17. Evaluation of the renal resistive index and pulsatility index in patients with pleural effusion by duplex Doppler ultrasonography.

    PubMed

    Değirmenci, Nevbahar Akcar; Metintaş, Muzaffer; Atlanoglu, Sahinde; Yıldırım, Huseyin

    2013-01-01

    The aim of the study was to evaluate the renal resistive index (RI) and pulsatility index (PI) in patients with pleural effusion (PE). We studied the mean renal RI and PI in 50 patients with PE and 30 healthy volunteers by Doppler sonography. We grouped effusion as unilateral and bilateral. Statistical analysis was done by independent t test and correlation coefficient analysis. The mean RI/PI in healthy volunteers and in PE patients was 0.58/0.93 and 0.72/1.35, respectively. We observed a significantly higher RI and PI in patients when compared with healthy volunteers (all p < 0.001). We found no difference between the renal RI or PI related to unilateral (0.71 or 1.34, respectively) or bilateral effusion (0.74 or 1.55, respectively) (p > 0.05). Pleural effusion might result in increased renal impedance as seen in cirrhosis, which is a rather complicated pathophysiological process, without causing any morphological changes in kidneys.

  18. Neutron-Encoded Protein Quantification by Peptide Carbamylation

    NASA Astrophysics Data System (ADS)

    Ulbrich, Arne; Merrill, Anna E.; Hebert, Alexander S.; Westphall, Michael S.; Keller, Mark P.; Attie, Alan D.; Coon, Joshua J.

    2014-01-01

    We describe a chemical tag for duplex proteome quantification using neutron encoding (NeuCode). The method utilizes the straightforward, efficient, and inexpensive carbamylation reaction. We demonstrate the utility of NeuCode carbamylation by accurately measuring quantitative ratios from tagged yeast lysates mixed in known ratios and by applying this method to quantify differential protein expression in mice fed a either control or high-fat diet.

  19. Pseudo color ghost coding imaging with pseudo thermal light

    NASA Astrophysics Data System (ADS)

    Duan, De-yang; Xia, Yun-jie

    2018-04-01

    We present a new pseudo color imaging scheme named pseudo color ghost coding imaging based on ghost imaging but with multiwavelength source modulated by a spatial light modulator. Compared with conventional pseudo color imaging where there is no nondegenerate wavelength spatial correlations resulting in extra monochromatic images, the degenerate wavelength and nondegenerate wavelength spatial correlations between the idle beam and signal beam can be obtained simultaneously. This scheme can obtain more colorful image with higher quality than that in conventional pseudo color coding techniques. More importantly, a significant advantage of the scheme compared to the conventional pseudo color coding imaging techniques is the image with different colors can be obtained without changing the light source and spatial filter.

  20. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    PubMed

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p

  1. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  2. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  3. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  4. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  5. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  6. Percutaneous ethanol injection of hyperfunctioning thyroid nodules: long-term follow-up in 125 patients.

    PubMed

    Tarantino, Luciano; Francica, Giampiero; Sordelli, Ignazio; Sperlongano, Pasquale; Parmeggiani, Domenico; Ripa, Carmine; Parmeggiani, Umberto

    2008-03-01

    The purpose of this study was to assess the long-term efficacy of percutaneous ethanol injection (PEI) for the treatment of hyperfunctioning thyroid nodules. One hundred twenty-five patients (88 women, 37 men; age range, 17-76 years; mean age, 53 years) with 127 hyperfunctioning thyroid nodules (volume, 1.2-90 mL; mean, 10.3 mL) were treated with PEI. There were 1-11 PEI sessions per patient (average, 3.9) performed, with injection of 1-14 mL of ethanol per session (total injected ethanol per patient, 3-108 mL; mean, 14.0 mL). Efficacy of the treatment was assessed with color Doppler sonography; scintigraphy; and free triiodothyronine (FT3), free thyroxine (FT4), and thyroid-stimulating hormone (TSH) assays. Follow-up (9-144 months; median, 60 months) was performed with TSH and color Doppler sonography every 2 months for 6 months and every 6 months thereafter. Three (2.4%) of 125 patients refused completion of PEI therapy because of pain. Results are reported in 122 patients with 124 nodules. All 122 patients showed posttreatment normal levels of FT3, FT4, and TSH. A complete cure (absent uptake in the nodule and recovery of normal uptake in the thyroid parenchyma) was obtained in 113 (93%) of 122 patients-115 (92.7%) of 124 treated nodules. Residual hyperfunctioning nodular tissue along with decreased thyroid parenchyma uptake (partial cure) was present in nine patients accounting for nine (7.3%) of 124 nodules. Rates of complete cure after PEI were: overall nodules, 115 (92.7%) of 124; nodules < or = 10 mL, 63 (94.0%) of 67; nodules > 10 to < or = 30 mL, 32 (91.4%) of 35; nodules > 30 to < or = 60 mL, 17 (89.5%) of 19; nodules > 60 mL, three (100%) of three. The overall rate of major complications (transient laryngeal nerve damage, two patients; abscess and hematoma, one patient each) was four (3.2%) of 125 patients. Follow-up examinations showed marked shrinkage of 112 treated nodules ranging from 50% to 90% of the pretreatment volume (mean, 66%) and new growth of hyperfunctioning tissue in four patients at color Doppler sonography and scintigraphy at 12, 18, 18, and 48 months' follow-up, respectively. However, all patients remained euthyroid (low or normal TSH and normal FT3 and FT4) during follow-up. PEI of hyperfunctioning thyroid nodules seems to be an effective and safe alternative to traditional treatment. It also appears to be effective in patients with hyperfunctioning thyroid nodules larger than 30 mL.

  7. Braiding by Majorana tracking and long-range CNOT gates with color codes

    NASA Astrophysics Data System (ADS)

    Litinski, Daniel; von Oppen, Felix

    2017-11-01

    Color-code quantum computation seamlessly combines Majorana-based hardware with topological error correction. Specifically, as Clifford gates are transversal in two-dimensional color codes, they enable the use of the Majoranas' non-Abelian statistics for gate operations at the code level. Here, we discuss the implementation of color codes in arrays of Majorana nanowires that avoid branched networks such as T junctions, thereby simplifying their realization. We show that, in such implementations, non-Abelian statistics can be exploited without ever performing physical braiding operations. Physical braiding operations are replaced by Majorana tracking, an entirely software-based protocol which appropriately updates the Majoranas involved in the color-code stabilizer measurements. This approach minimizes the required hardware operations for single-qubit Clifford gates. For Clifford completeness, we combine color codes with surface codes, and use color-to-surface-code lattice surgery for long-range multitarget CNOT gates which have a time overhead that grows only logarithmically with the physical distance separating control and target qubits. With the addition of magic state distillation, our architecture describes a fault-tolerant universal quantum computer in systems such as networks of tetrons, hexons, or Majorana box qubits, but can also be applied to nontopological qubit platforms.

  8. Doppler sonography of the uterine arteries during a superovulatory regime in cattle. Uterine blood flow in superovulated cattle.

    PubMed

    Honnens, A; Niemann, H; Paul, V; Meyer, H H D; Bollwein, H

    2008-09-15

    Transrectal color Doppler sonography was used to investigate the effects of a gonadotropin treatment to induce superovulation on uterine blood flow and its relationship with steroid hormone levels, ovarian response and embryo yield in dairy cows. The estrous cycle of 42 cows was synchronized by using PGF(2alpha) during diestrus and GnRH 48 h later (Day 0). Cows were examined on the day of eCG (2750 IU)-administration (Day 10), 3 days after eCG (Day 13) and 7 days after artificial insemination (Day 22), including the determination of total estrogens (E) and progesterone (P(4)) in peripheral plasma. Eight days after insemination (Day 23) the uterus was flushed and the number of total ova and embryos as well as transferable embryos was determined. The ovarian response was defined by the number of follicles>5.0mm in diameter on Day 13 and the number of corpora lutea on Day 22. Uterine blood flow was reflected by the blood flow volume (BFV) and the pulsatility index (PI) in the uterine arteries. Both variables showed distinct changes throughout the superovulatory cycle: BFV increased by 94% and PI decreased by 30% between Days 10 and 22 (P<0.0001). On Day 13, BFV but not PI correlated with follicle numbers (r=0.35; P<0.05); no correlation was found with E and P(4) (P>0.05). On Day 22, BFV correlated positively and PI correlated negatively with the number of corpora lutea (r=0.45 and r=-0.37; P<0.05) and P(4) (r=0.39 and r=-0.30; P<0.05). The number of transferable embryos was solely related to BFV measured on Day 13 (r=0.32; P<0.05). Our results show for the first time that in cows a superovulatory treatment is associated with a marked increase in BFV and a marked decrease in PI in the uterine arteries, concurrent with the development of multiple follicles and corpora lutea. However, transrectal color Doppler sonography of the uterine arteries does not facilitate the prediction of embryo yields following superovulatory treatment.

  9. Imaging of human tooth using ultrasound based chirp-coded nonlinear time reversal acoustics.

    PubMed

    Dos Santos, Serge; Prevorovsky, Zdenek

    2011-08-01

    Human tooth imaging sonography is investigated experimentally with an acousto-optic noncoupling set-up based on the chirp-coded nonlinear time reversal acoustic concept. The complexity of the tooth internal structure (enamel-dentine interface, cracks between internal tubules) is analyzed by adapting the nonlinear elastic wave spectroscopy (NEWS) with the objective of the tomography of damage. Optimization of excitations using intrinsic symmetries, such as time reversal (TR) invariance, reciprocity, correlation properties are then proposed and implemented experimentally. The proposed medical application of this TR-NEWS approach is implemented on a third molar human tooth and constitutes an alternative of noncoupling echodentography techniques. A 10 MHz bandwidth ultrasonic instrumentation has been developed including a laser vibrometer and a 20 MHz contact piezoelectric transducer. The calibrated chirp-coded TR-NEWS imaging of the tooth is obtained using symmetrized excitations, pre- and post-signal processing, and the highly sensitive 14 bit resolution TR-NEWS instrumentation previously calibrated. Nonlinear signature coming from the symmetry properties is observed experimentally in the tooth using this bi-modal TR-NEWS imaging after and before the focusing induced by the time-compression process. The TR-NEWS polar B-scan of the tooth is described and suggested as a potential application for modern echodentography. It constitutes the basis of the self-consistent harmonic imaging sonography for monitoring cracks propagation in the dentine, responsible of human tooth structural health. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. The Use of Color-Coded Genograms in Family Therapy.

    ERIC Educational Resources Information Center

    Lewis, Karen Gail

    1989-01-01

    Describes a variable color-coding system which has been added to the standard family genogram in which characteristics or issues associated with a particular presenting problem or for a particular family are arbitrarily assigned a color. Presents advantages of color-coding, followed by clinical examples. (Author/ABL)

  11. Color coding of control room displays: the psychocartography of visual layering effects.

    PubMed

    Van Laar, Darren; Deshe, Ofer

    2007-06-01

    To evaluate which of three color coding methods (monochrome, maximally discriminable, and visual layering) used to code four types of control room display format (bars, tables, trend, mimic) was superior in two classes of task (search, compare). It has recently been shown that color coding of visual layers, as used in cartography, may be used to color code any type of information display, but this has yet to be fully evaluated. Twenty-four people took part in a 2 (task) x 3 (coding method) x 4 (format) wholly repeated measures design. The dependent variables assessed were target location reaction time, error rates, workload, and subjective feedback. Overall, the visual layers coding method produced significantly faster reaction times than did the maximally discriminable and the monochrome methods for both the search and compare tasks. No significant difference in errors was observed between conditions for either task type. Significantly less perceived workload was experienced with the visual layers coding method, which was also rated more highly than the other coding methods on a 14-item visual display quality questionnaire. The visual layers coding method is superior to other color coding methods for control room displays when the method supports the user's task. The visual layers color coding method has wide applicability to the design of all complex information displays utilizing color coding, from the most maplike (e.g., air traffic control) to the most abstract (e.g., abstracted ecological display).

  12. Full Duplex, Spread Spectrum Radio System

    NASA Technical Reports Server (NTRS)

    Harvey, Bruce A.

    2000-01-01

    The goal of this project was to support the development of a full duplex, spread spectrum voice communications system. The assembly and testing of a prototype system consisting of a Harris PRISM spread spectrum radio, a TMS320C54x signal processing development board and a Zilog Z80180 microprocessor was underway at the start of this project. The efforts under this project were the development of multiple access schemes, analysis of full duplex voice feedback delays, and the development and analysis of forward error correction (FEC) algorithms. The multiple access analysis involved the selection between code division multiple access (CDMA), frequency division multiple access (FDMA) and time division multiple access (TDMA). Full duplex voice feedback analysis involved the analysis of packet size and delays associated with full loop voice feedback for confirmation of radio system performance. FEC analysis included studies of the performance under the expected burst error scenario with the relatively short packet lengths, and analysis of implementation in the TMS320C54x digital signal processor. When the capabilities and the limitations of the components used were considered, the multiple access scheme chosen was a combination TDMA/FDMA scheme that will provide up to eight users on each of three separate frequencies. Packets to and from each user will consist of 16 samples at a rate of 8,000 samples per second for a total of 2 ms of voice information. The resulting voice feedback delay will therefore be 4 - 6 ms. The most practical FEC algorithm for implementation was a convolutional code with a Viterbi decoder. Interleaving of the bits of each packet will be required to offset the effects of burst errors.

  13. A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sievert, Horst, E-mail: info@cvcfrankfurt.de; Franke, Jennifer; Grad, Ygael

    Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotidmore » duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.« less

  14. Topological color codes on Union Jack lattices: a stable implementation of the whole Clifford group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katzgraber, Helmut G.; Theoretische Physik, ETH Zurich, CH-8093 Zurich; Bombin, H.

    We study the error threshold of topological color codes on Union Jack lattices that allow for the full implementation of the whole Clifford group of quantum gates. After mapping the error-correction process onto a statistical mechanical random three-body Ising model on a Union Jack lattice, we compute its phase diagram in the temperature-disorder plane using Monte Carlo simulations. Surprisingly, topological color codes on Union Jack lattices have a similar error stability to color codes on triangular lattices, as well as to the Kitaev toric code. The enhanced computational capabilities of the topological color codes on Union Jack lattices with respectmore » to triangular lattices and the toric code combined with the inherent robustness of this implementation show good prospects for future stable quantum computer implementations.« less

  15. Integrating Sonography Training Into Undergraduate Medical Education: A Study of the Previous Exposure of One Institution's Incoming Residents.

    PubMed

    Day, James; Davis, Joshua; Riesenberg, Lee Ann; Heil, Daniel; Berg, Katherine; Davis, Robyn; Berg, Dale

    2015-07-01

    Sonography is a crucial and versatile tool within the field of medicine. Recent advancements in technology have led to increased use of point-of-care sonography. We designed a survey to assess prior point-of-care sonography training among incoming interns at an academic teaching hospital. In 2012 and 2013, we surveyed incoming interns (n = 154 and 145, respectively) regarding point-of-care sonography training received during medical school. The survey questions included formal didactic sessions, bedside instruction, and the use of simulation technology. One-fourth (26.3% in 2012 and 23.4% in 2013) of responding interns reported having never done an ultrasound scan at the bedside. In 2012 and 2013, 55.0% and 55.6% of respondents reported never having done an ultrasound scan in a simulation center, respectively. Interns agreed that sonography education should be provided during medical school. On average, interns disagreed with the statement that sonography should be taught in residency only. There was no significant difference in the sex or general previous experience with sonography across both intern classes. Point-of-care sonography is inconsistently taught in medical school. The interns in our study also thought that sonography education should begin in medical school, and sonography should be taught by using simulation and at the bedside. © 2015 by the American Institute of Ultrasound in Medicine.

  16. Color Coded Cards for Student Behavior Management in Higher Education Environments

    ERIC Educational Resources Information Center

    Alhalabi, Wadee; Alhalabi, Mobeen

    2017-01-01

    The Color Coded Cards system as a possibly effective class management tool is the focus of this research. The Color Coded Cards system involves each student being given a card with a specific color based on his or her behavior. The main objective of the research is to find out whether this system effectively improves students' behavior, thus…

  17. Bi-functional anodic TiO2 oxide: Nanotubes for wettability control and barrier oxide for uniform coloring

    NASA Astrophysics Data System (ADS)

    Kim, Sunkyu; Jung, Minkyeong; Kim, Moonsu; Choi, Jinsub

    2017-06-01

    A uniformly colored TiO2, on which the surface is functionalized with nanotubes to control wettability, was prepared by a two-step anodization; the first anodization was carried out to prepare nanotubes for a super-hydrophilic or -hydrophobic surface and the second anodization was performed to fabricate a thin film barrier oxide to ensure uniform coloring. The effect of the nanotubes on barrier oxide coloring was examined by spectrophotometry and UV-vis-IR spectroscopy. We found four different regimes governing the color changes in terms of anodization voltage, indicating that the color of the duplex TiO2 was primarily determined by the thickness of the barrier oxide layer formed during the second anodization step. The surface wettability, as confirmed by the water contact angle, revealed that the single barrier TiO2 yielded 74.6° ± 2.1, whereas the nanotubes on the barrier oxide imparted super-hydrophilic properties as a result of increasing surface roughness as well as imparting a higher hydrophobicity after organic acid treatment.

  18. Evaluation of transcatheter arterial embolization therapy on hepatocellular carcinomas using contrast-enhanced harmonic power Doppler sonography: comparison with CT, power Doppler sonography, and dynamic MRI.

    PubMed

    Shima, Toshihide; Mizuno, Masayuki; Otsuji, Hideaki; Mizuno, Chiemi; Obata, Hirozumi; Park, Hyohun; Nakajo, Shinobu; Okanoue, Takeshi

    2005-09-01

    The aim of this study was to assess and compare the sensitivity of power Doppler sonography, contrast-enhanced sonography, plain computed tomography (CT), and dynamic magnetic resonance imaging (MRI) for detecting hepatocellular carcinoma (HCC) nodules incompletely treated with transcatheter arterial embolization (TAE). A total of 63 unresectable HCC nodules were examined in this study. The HCCs were treated with TAE. All patients underwent plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI 1 week after TAE. The sensitivity of each modality to incompletely treated HCC nodules was compared. Detection of the residual viable HCC on angiography or tumor biopsy was regarded as the gold standard for the diagnosis of incomplete treatment. Twenty-four nodules (38%) were diagnosed as incompletely treated. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these incompletely treated nodules were 42% (10/24), 46% (11/24), 88% (21/24), and 79% (19/24), respectively. Eighty percent (19 nodules) of the 24 incompletely treated nodules were located within a depth of less than 8 cm. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these superficial incompletely treated nodules were 37% (7/19), 53% (10/19), 100% (19/19), and 74% (14/19), respectively. In contrast, the sensitivities of each modality to deeply located nodules were 60% (3/5), 20% (1/5), 40% (2/5), and 100% (5/5), respectively. Plain CT and power Doppler sonography had a low sensitivity to HCC nodules incompletely treated with TAE. Except for those that were deeply located, contrast-enhanced harmonic sonography showed the highest sensitivity in detecting incompletely treated HCC nodules.

  19. Joint sparse coding based spatial pyramid matching for classification of color medical image.

    PubMed

    Shi, Jun; Li, Yi; Zhu, Jie; Sun, Haojie; Cai, Yin

    2015-04-01

    Although color medical images are important in clinical practice, they are usually converted to grayscale for further processing in pattern recognition, resulting in loss of rich color information. The sparse coding based linear spatial pyramid matching (ScSPM) and its variants are popular for grayscale image classification, but cannot extract color information. In this paper, we propose a joint sparse coding based SPM (JScSPM) method for the classification of color medical images. A joint dictionary can represent both the color information in each color channel and the correlation between channels. Consequently, the joint sparse codes calculated from a joint dictionary can carry color information, and therefore this method can easily transform a feature descriptor originally designed for grayscale images to a color descriptor. A color hepatocellular carcinoma histological image dataset was used to evaluate the performance of the proposed JScSPM algorithm. Experimental results show that JScSPM provides significant improvements as compared with the majority voting based ScSPM and the original ScSPM for color medical image classification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Duplex Identification of Staphylococcus aureus by Aptamer and Gold Nanoparticles.

    PubMed

    Chang, Tianjun; Wang, Libo; Zhao, Kexu; Ge, Yu; He, Meng; Li, Gang

    2016-06-01

    Staphylococcus aureus is the top common pathogen causing infections and food poisoning. Identification of S. aureus is crucial for the disease diagnosis and regulation of food hygiene. Herein, we report an aptamer-AuNPs based method for duplex identification of S. aureus. Using AuNPs as an indicator, SA23, an aptamer against S. aureus, can well identify its target from Escherichia coli, Listeria monocytogenes and Pseudomonas aeruginosa. Furthermore, we find citrate-coated AuNPs can strongly bind to S. aureus, but not bind to Salmonella enterica and Proteus mirabilis, which leads to different color changes in salt solution. This colorimetric response is capable of distinguishing S. aureus from S. enteritidis and P. mirabilis. Thus, using the aptasensor and AuNPs together, S. aureus can be accurately identified from the common pathogens. This duplex identification system is a promising platform for simple visual identification of S. aureus. Additionally, in the aptasensing process, bacteria are incubated with aptamers and then be removed before the aptamers adding to AuNPs, which may avoid the interactions between bacteria and AuNPs. This strategy can be potentially applied in principle to detect other cells by AuNPs-based aptasensors.

  1. A process model for the heat-affected zone microstructure evolution in duplex stainless steel weldments: Part II. Application to electron beam welding

    NASA Astrophysics Data System (ADS)

    Hemmer, H.; Grong, Ø.; Klokkehaug, S.

    2000-03-01

    In the present investigation, a process model for electron beam (EB) welding of different grades of duplex stainless steels (i.e. SAF 2205 and 2507) has been developed. A number of attractive features are built into the original finite element code, including (1) a separate module for prediction of the penetration depth and distribution of the heat source into the plate, (2) adaptive refinement of the three-dimensional (3-D) element mesh for quick and reliable solution of the differential heat flow equation, and (3) special subroutines for calculation of the heat-affected zone (HAZ) microstructure evolution. The process model has been validated by comparison with experimental data obtained from in situ thermocouple measurements and optical microscope examinations. Subsequently, its aptness to alloy design and optimization of welding conditions for duplex stainless steels is illustrated in different numerical examples and case studies pertaining to EB welding of tubular joints.

  2. A blind dual color images watermarking based on IWT and state coding

    NASA Astrophysics Data System (ADS)

    Su, Qingtang; Niu, Yugang; Liu, Xianxi; Zhu, Yu

    2012-04-01

    In this paper, a state-coding based blind watermarking algorithm is proposed to embed color image watermark to color host image. The technique of state coding, which makes the state code of data set be equal to the hiding watermark information, is introduced in this paper. When embedding watermark, using Integer Wavelet Transform (IWT) and the rules of state coding, these components, R, G and B, of color image watermark are embedded to these components, Y, Cr and Cb, of color host image. Moreover, the rules of state coding are also used to extract watermark from the watermarked image without resorting to the original watermark or original host image. Experimental results show that the proposed watermarking algorithm cannot only meet the demand on invisibility and robustness of the watermark, but also have well performance compared with other proposed methods considered in this work.

  3. 29 CFR 1915.90 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Safety color code for marking physical hazards. 1915.90 Section 1915.90 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... General Working Conditions § 1915.90 Safety color code for marking physical hazards. The requirements...

  4. 29 CFR 1915.90 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Safety color code for marking physical hazards. 1915.90 Section 1915.90 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... General Working Conditions § 1915.90 Safety color code for marking physical hazards. The requirements...

  5. 29 CFR 1915.90 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Safety color code for marking physical hazards. 1915.90 Section 1915.90 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... General Working Conditions § 1915.90 Safety color code for marking physical hazards. The requirements...

  6. Doppler color imaging. Principles and instrumentation.

    PubMed

    Kremkau, F W

    1992-01-01

    DCI acquires Doppler-shifted echoes from a cross-section of tissue scanned by an ultrasound beam. These echoes are then presented in color and superimposed on the gray-scale anatomic image of non-Doppler-shifted echoes received during the scan. The flow echoes are assigned colors according to the color map chosen. Usually red, yellow, or white indicates positive Doppler shifts (approaching flow) and blue, cyan, or white indicates negative shifts (receding flow). Green is added to indicate variance (disturbed or turbulent flow). Several pulses (the number is called the ensemble length) are needed to generate a color scan line. Linear, convex, phased, and annular arrays are used to acquire the gray-scale and color-flow information. Doppler color-flow instruments are pulsed-Doppler instruments and are subject to the same limitations, such as Doppler angle dependence and aliasing, as other Doppler instruments. Color controls include gain, TGC, map selection, variance on/off, persistence, ensemble length, color/gray priority. Nyquist limit (PRF), baseline shift, wall filter, and color window angle, location, and size. Doppler color-flow instruments generally have output intensities intermediate between those of gray-scale imaging and pulsed-Doppler duplex instruments. Although there is no known risk with the use of color-flow instruments, prudent practice dictates that they be used for medical indications and with the minimum exposure time and instrument output required to obtain the needed diagnostic information.

  7. Color visualization for fluid flow prediction

    NASA Technical Reports Server (NTRS)

    Smith, R. E.; Speray, D. E.

    1982-01-01

    High-resolution raster scan color graphics allow variables to be presented as a continuum, in a color-coded picture that is referenced to a geometry such as a flow field grid or a boundary surface. Software is used to map a scalar variable such as pressure or temperature, defined on a two-dimensional slice of a flow field. The geometric shape is preserved in the resulting picture, and the relative magnitude of the variable is color-coded onto the geometric shape. The primary numerical process for color coding is an efficient search along a raster scan line to locate the quadrilteral block in the grid that bounds each pixel on the line. Tension spline interpolation is performed relative to the grid for specific values of the scalar variable, which is then color coded. When all pixels for the field of view are color-defined, a picture is played back from a memory device onto a television screen.

  8. Neonatal cranial sonography: A concise review for clinicians

    PubMed Central

    Gupta, Pankaj; Sodhi, Kushaljit Singh; Saxena, Akshay Kumar; Khandelwal, Niranjan; Singhi, Pratibha

    2016-01-01

    Cranial sonography continues to hold an important place in neonatal care. Attributes favorable to sonography that make it almost indispensable for routine care of the newborn includes easy access, low cost, portability, lack of ionizing radiations and exemption from sedation or anaesthesia. Cranial sonography has highest impact in neonates suspected to have meningitis and its complications; perinatal ischemia particularly periventricular leukomalacia (PVL); hydrocephalus resulting from multitude of causes and hemorrhage. Not withstanding this, cranial sonography has yielded results for a repertoire of indications. Approach to cranial sonography involves knowledge of the normal developmental anatomy of brain parenchyma for correct interpretation. Correct technique, taking advantage of multiple sonographic windows and variable frequencies of the ultrasound probes allows a detailed and comprehensive examination of brain parenchyma. In this review, we discuss the technique, normal and variant anatomy as well as disease entities of neonatal cranial sonography. PMID:27195026

  9. Optimizing sgRNA structure to improve CRISPR-Cas9 knockout efficiency.

    PubMed

    Dang, Ying; Jia, Gengxiang; Choi, Jennie; Ma, Hongming; Anaya, Edgar; Ye, Chunting; Shankar, Premlata; Wu, Haoquan

    2015-12-15

    Single-guide RNA (sgRNA) is one of the two key components of the clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 genome-editing system. The current commonly used sgRNA structure has a shortened duplex compared with the native bacterial CRISPR RNA (crRNA)-transactivating crRNA (tracrRNA) duplex and contains a continuous sequence of thymines, which is the pause signal for RNA polymerase III and thus could potentially reduce transcription efficiency. Here, we systematically investigate the effect of these two elements on knockout efficiency and showed that modifying the sgRNA structure by extending the duplex length and mutating the fourth thymine of the continuous sequence of thymines to cytosine or guanine significantly, and sometimes dramatically, improves knockout efficiency in cells. In addition, the optimized sgRNA structure also significantly increases the efficiency of more challenging genome-editing procedures, such as gene deletion, which is important for inducing a loss of function in non-coding genes. By a systematic investigation of sgRNA structure we find that extending the duplex by approximately 5 bp combined with mutating the continuous sequence of thymines at position 4 to cytosine or guanine significantly increases gene knockout efficiency in CRISPR-Cas9-based genome editing experiments.

  10. Teaching Speech Organization and Outlining Using a Color-Coded Approach.

    ERIC Educational Resources Information Center

    Hearn, Ralene

    The organization/outlining unit in the basic Public Speaking course can be made more interesting by using a color-coded instructional method that captivates students, facilitates understanding, and provides the opportunity for interesting reinforcement activities. The two part lesson includes a mini-lecture with a color-coded outline and a two…

  11. Imitation Learning Errors Are Affected by Visual Cues in Both Performance and Observation Phases.

    PubMed

    Mizuguchi, Takashi; Sugimura, Ryoko; Shimada, Hideaki; Hasegawa, Takehiro

    2017-08-01

    Mechanisms of action imitation were examined. Previous studies have suggested that success or failure of imitation is determined at the point of observing an action. In other words, cognitive processing after observation is not related to the success of imitation; 20 university students participated in each of three experiments in which they observed a series of object manipulations consisting of four elements (hands, tools, object, and end points) and then imitated the manipulations. In Experiment 1, a specific intially observed element was color coded, and the specific manipulated object at the imitation stage was identically color coded; participants accurately imitated the color coded element. In Experiment 2, a specific element was color coded at the observation but not at the imitation stage, and there were no effects of color coding on imitation. In Experiment 3, participants were verbally instructed to attend to a specific element at the imitation stage, but the verbal instructions had no effect. Thus, the success of imitation may not be determined at the stage of observing an action and color coding can provide a clue for imitation at the imitation stage.

  12. [Semiotics of lesions of the cerebral venous collectors on application of noninvasive techniques of x-ray diagnosis].

    PubMed

    Semenov, S; Abalmasov, V

    2001-01-01

    The study included application of a complex of the noninvasive diagnostic techniques such as MR tomography, MR venography, duplex scanning of the internal jugular veins, and transcranial Doppler sonography. The authors provide a detailed description of the semiotics of the MR signs of cerebral venous collector lesion in patients with thrombosis, extravasal compression, aneurysms, and developmental anomalies. Present the quantitative ultrasound parameters of hemodynamics in the efferent vessels of the brain accessible to inspections describe the effect of spontaneous echo-opacification in the internal jugular veins, which is assumed to be a predictor of thrombosis. Intravenous injection of magnevist resulted in an appreciable refinement of visualization of small dural sinuses at MR venography thereby allowing for the diagnosis of their thrombosis. It is suggested that the use of the entire complex of the x-ray modalities under consideration may lead to a more complete and noninvasive evaluation of the nature of cerebral venous insufficiency and of the degree of hemodynamic significance. Moreover, this will make it possible to outline approaches to therapeutic or surgical correction of the disease.

  13. Comparison of memory thresholds for planar qudit geometries

    NASA Astrophysics Data System (ADS)

    Marks, Jacob; Jochym-O'Connor, Tomas; Gheorghiu, Vlad

    2017-11-01

    We introduce and analyze a new type of decoding algorithm called general color clustering, based on renormalization group methods, to be used in qudit color codes. The performance of this decoder is analyzed under a generalized bit-flip error model, and is used to obtain the first memory threshold estimates for qudit 6-6-6 color codes. The proposed decoder is compared with similar decoding schemes for qudit surface codes as well as the current leading qubit decoders for both sets of codes. We find that, as with surface codes, clustering performs sub-optimally for qubit color codes, giving a threshold of 5.6 % compared to the 8.0 % obtained through surface projection decoding methods. However, the threshold rate increases by up to 112% for large qudit dimensions, plateauing around 11.9 % . All the analysis is performed using QTop, a new open-source software for simulating and visualizing topological quantum error correcting codes.

  14. Reading color barcodes using visual snakes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaub, Hanspeter

    2004-05-01

    Statistical pressure snakes are used to track a mono-color target in an unstructured environment using a video camera. The report discusses an algorithm to extract a bar code signal that is embedded within the target. The target is assumed to be rectangular in shape, with the bar code printed in a slightly different saturation and value in HSV color space. Thus, the visual snake, which primarily weighs hue tracking errors, will not be deterred by the presence of the color bar codes in the target. The bar code is generate with the standard 3 of 9 method. Using this method,more » the numeric bar codes reveal if the target is right-side-up or up-side-down.« less

  15. Color-coding cancer and stromal cells with genetic reporters in a patient-derived orthotopic xenograft (PDOX) model of pancreatic cancer enhances fluorescence-guided surgery

    PubMed Central

    Yano, Shuya; Hiroshima, Yukihiko; Maawy, Ali; Kishimoto, Hiroyuki; Suetsugu, Atsushi; Miwa, Shinji; Toneri, Makoto; Yamamoto, Mako; Katz, Matthew H.G.; Fleming, Jason B.; Urata, Yasuo; Tazawa, Hiroshi; Kagawa, Shunsuke; Bouvet, Michael; Fujiwara, Toshiyoshi; Hoffman, Robert M.

    2015-01-01

    Precise fluorescence-guided surgery (FGS) for pancreatic cancer has the potential to greatly improve the outcome in this recalcitrant disease. In order to achieve this goal, we have used genetic reporters to color code cancer and stroma cells in a patient-derived orthotopic xenograft (PDOX) model. The telomerase-dependent green fluorescent protein (GFP) containing adenovirus OBP401 was used to label the cancer cells of the pancreatic cancer PDOX. The PDOX was previously grown in a red fluorescent protein (RFP) transgenic mouse that stably labeled the PDOX stroma cells bright red. The color-coded PDOX model enabled FGS to completely resect the pancreatic tumors including stroma. Dual-colored FGS significantly prevented local recurrence, which bright-light surgery (BLS) or single color could not. FGS, with color-coded cancer and stroma cells has important potential for improving the outcome of recalcitrant cancer. PMID:26088297

  16. How Color Coding Formulaic Writing Enhances Organization: A Qualitative Approach for Measuring Student Affect

    ERIC Educational Resources Information Center

    Geigle, Bryce A.

    2014-01-01

    The aim of this thesis is to investigate and present the status of student synthesis with color coded formula writing for grade level six through twelve, and to make recommendations for educators to teach writing structure through a color coded formula system in order to increase classroom engagement and lower students' affect. The thesis first…

  17. Parametric color coding of digital subtraction angiography.

    PubMed

    Strother, C M; Bender, F; Deuerling-Zheng, Y; Royalty, K; Pulfer, K A; Baumgart, J; Zellerhoff, M; Aagaard-Kienitz, B; Niemann, D B; Lindstrom, M L

    2010-05-01

    Color has been shown to facilitate both visual search and recognition tasks. It was our purpose to examine the impact of a color-coding algorithm on the interpretation of 2D-DSA acquisitions by experienced and inexperienced observers. Twenty-six 2D-DSA acquisitions obtained as part of routine clinical care from subjects with a variety of cerebrovascular disease processes were selected from an internal data base so as to include a variety of disease states (aneurysms, AVMs, fistulas, stenosis, occlusions, dissections, and tumors). Three experienced and 3 less experienced observers were each shown the acquisitions on a prerelease version of a commercially available double-monitor workstation (XWP, Siemens Healthcare). Acquisitions were presented first as a subtracted image series and then as a single composite color-coded image of the entire acquisition. Observers were then asked a series of questions designed to assess the value of the color-coded images for the following purposes: 1) to enhance their ability to make a diagnosis, 2) to have confidence in their diagnosis, 3) to plan a treatment, and 4) to judge the effect of a treatment. The results were analyzed by using 1-sample Wilcoxon tests. Color-coded images enhanced the ease of evaluating treatment success in >40% of cases (P < .0001). They also had a statistically significant impact on treatment planning, making planning easier in >20% of the cases (P = .0069). In >20% of the examples, color-coding made diagnosis and treatment planning easier for all readers (P < .0001). Color-coding also increased the confidence of diagnosis compared with the use of DSA alone (P = .056). The impact of this was greater for the naïve readers than for the expert readers. At no additional cost in x-ray dose or contrast medium, color-coding of DSA enhanced the conspicuity of findings on DSA images. It was particularly useful in situations in which there was a complex flow pattern and in evaluation of pre- and posttreatment acquisitions. Its full potential remains to be defined.

  18. Colorful Revision: Color-Coded Comments Connected to Instruction

    ERIC Educational Resources Information Center

    Mack, Nancy

    2013-01-01

    Many teachers have had a favorable response to their experimentation with digital feedback on students' writing. Students much preferred a simpler system of highlighting and commenting in color. After experimentation the author found that this color-coded system was more effective for them and less time-consuming for her. Of course, any system…

  19. A conflict-based model of color categorical perception: evidence from a priming study.

    PubMed

    Hu, Zhonghua; Hanley, J Richard; Zhang, Ruiling; Liu, Qiang; Roberson, Debi

    2014-10-01

    Categorical perception (CP) of color manifests as faster or more accurate discrimination of two shades of color that straddle a category boundary (e.g., one blue and one green) than of two shades from within the same category (e.g., two different shades of green), even when the differences between the pairs of colors are equated according to some objective metric. The results of two experiments provide new evidence for a conflict-based account of this effect, in which CP is caused by competition between visual and verbal/categorical codes on within-category trials. According to this view, conflict arises because the verbal code indicates that the two colors are the same, whereas the visual code indicates that they are different. In Experiment 1, two shades from the same color category were discriminated significantly faster when the previous trial also comprised a pair of within-category colors than when the previous trial comprised a pair from two different color categories. Under the former circumstances, the CP effect disappeared. According to the conflict-based model, response conflict between visual and categorical codes during discrimination of within-category pairs produced an adjustment of cognitive control that reduced the weight given to the categorical code relative to the visual code on the subsequent trial. Consequently, responses on within-category trials were facilitated, and CP effects were reduced. The effectiveness of this conflict-based account was evaluated in comparison with an alternative view that CP reflects temporary warping of perceptual space at the boundaries between color categories.

  20. Color and Grey Scale in Sonar Displays

    NASA Technical Reports Server (NTRS)

    Kraiss, K. F.; Kuettelwesch, K. H.

    1984-01-01

    In spite of numerous publications 1 it is still rather unclear, whether color is of any help in sonar displays. The work presented here deals with a particular type of sonar data, i.e., LOFAR-grams (low frequency analysing and recording) where acoustic sensor data are continuously written as a time-frequency plot. The question to be answered quantitatively is, whether color coding does improve target detection when compared with a grey scale code. The data show significant differences in receiver-operating characteristics performance for the selected codes. In addition it turned out, that the background noise level affects the performance dramatically for some color codes, while others remain stable or even improve. Generally valid rules are presented on how to generate useful color scales for this particular application.

  1. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    PubMed

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed sonography is positive.

  2. Color-coded fluid-attenuated inversion recovery images improve inter-rater reliability of fluid-attenuated inversion recovery signal changes within acute diffusion-weighted image lesions.

    PubMed

    Kim, Bum Joon; Kim, Yong-Hwan; Kim, Yeon-Jung; Ahn, Sung Ho; Lee, Deok Hee; Kwon, Sun U; Kim, Sang Joon; Kim, Jong S; Kang, Dong-Wha

    2014-09-01

    Diffusion-weighted image fluid-attenuated inversion recovery (FLAIR) mismatch has been considered to represent ischemic lesion age. However, the inter-rater agreement of diffusion-weighted image FLAIR mismatch is low. We hypothesized that color-coded images would increase its inter-rater agreement. Patients with ischemic stroke <24 hours of a clear onset were retrospectively studied. FLAIR signal change was rated as negative, subtle, or obvious on conventional and color-coded FLAIR images based on visual inspection. Inter-rater agreement was evaluated using κ and percent agreement. The predictive value of diffusion-weighted image FLAIR mismatch for identification of patients <4.5 hours of symptom onset was evaluated. One hundred and thirteen patients were enrolled. The inter-rater agreement of FLAIR signal change improved from 69.9% (k=0.538) with conventional images to 85.8% (k=0.754) with color-coded images (P=0.004). Discrepantly rated patients on conventional, but not on color-coded images, had a higher prevalence of cardioembolic stroke (P=0.02) and cortical infarction (P=0.04). The positive predictive value for patients <4.5 hours of onset was 85.3% and 71.9% with conventional and 95.7% and 82.1% with color-coded images, by each rater. Color-coded FLAIR images increased the inter-rater agreement of diffusion-weighted image FLAIR recovery mismatch and may ultimately help identify unknown-onset stroke patients appropriate for thrombolysis. © 2014 American Heart Association, Inc.

  3. How often do neuroradiologists perform sonography of the carotid arteries? A survey of academic and nonacademic radiology practices, with implications for fellowship training.

    PubMed

    Friedman, David P; Maitino, Andrea J

    2003-08-01

    Debate in the neuroradiology community surrounds the amount of formal training in sonography of the carotid arteries that should be provided to fellows. This study was designed to assess current practice patterns at both academic and nonacademic practices regarding the performance of carotid sonography. A neurovascular radiology survey was sent to all 102 program directors of neuroradiology fellowships in the United States and Canada (academic practices). The survey was also sent to 146 randomly selected senior members of the ASNR (three per state, except one each for Alaska and Vermont) who were not affiliated with fellowship programs (nonacademic practices). Fifty-seven surveys from academic practices and 70 surveys from nonacademic practices were returned. Radiologists at academic practices performed approximately 42% of studies (general radiologists or sonography specialists, 36%; neuroradiologists, 5%; cardiovascular radiologists, 1%). Nonradiologists performed approximately 58% of studies (vascular surgeons, 47%; neurologists, 10%; cardiologists, 1%; neurosurgeons, <1%). Neuroradiologists performed carotid sonography at 11% (6/57) of academic practices. On average, radiologists at nonacademic practices performed approximately 62% of studies (general radiologists or sonography specialists, 38%; neuroradiologists, 15%; cardiovascular radiologists, 9%). Nonradiologists performed approximately 38% of studies (vascular surgeons, 25%; neurologists, 6%; cardiologists or internists, 6%). Neuroradiologists performed carotid sonography at 53% (37/70) of nonacademic practices. At most academic practices, neuroradiologists do not perform sonography of the carotid arteries. This may explain the reluctance of some fellowships to provide formal training in this technique. In contrast, although neuroradiologists perform carotid sonography at a majority of the nonacademic practices, the percentage of studies that they perform is small; moreover, neuroradiologists perform far fewer studies than do general radiologists or sonography specialists.

  4. Color inference in visual communication: the meaning of colors in recycling.

    PubMed

    Schloss, Karen B; Lessard, Laurent; Walmsley, Charlotte S; Foley, Kathleen

    2018-01-01

    People interpret abstract meanings from colors, which makes color a useful perceptual feature for visual communication. This process is complicated, however, because there is seldom a one-to-one correspondence between colors and meanings. One color can be associated with many different concepts (one-to-many mapping) and many colors can be associated with the same concept (many-to-one mapping). We propose that to interpret color-coding systems, people perform assignment inference to determine how colors map onto concepts. We studied assignment inference in the domain of recycling. Participants saw images of colored but unlabeled bins and were asked to indicate which bins they would use to discard different kinds of recyclables and trash. In Experiment 1, we tested two hypotheses for how people perform assignment inference. The local assignment hypothesis predicts that people simply match objects with their most strongly associated color. The global assignment hypothesis predicts that people also account for the association strengths between all other objects and colors within the scope of the color-coding system. Participants discarded objects in bins that optimized the color-object associations of the entire set, which is consistent with the global assignment hypothesis. This sometimes resulted in discarding objects in bins whose colors were weakly associated with the object, even when there was a stronger associated option available. In Experiment 2, we tested different methods for encoding color-coding systems and found that people were better at assignment inference when color sets simultaneously maximized the association strength between assigned color-object parings while minimizing associations between unassigned pairings. Our study provides an approach for designing intuitive color-coding systems that facilitate communication through visual media such as graphs, maps, signs, and artifacts.

  5. A regulatory RNA is involved in RNA duplex formation and biofilm regulation in Sulfolobus acidocaldarius.

    PubMed

    Orell, Alvaro; Tripp, Vanessa; Aliaga-Tobar, Victor; Albers, Sonja-Verena; Maracaja-Coutinho, Vinicius; Randau, Lennart

    2018-05-18

    Non-coding RNAs (ncRNA) are involved in essential biological processes in all three domains of life. The regulatory potential of ncRNAs in Archaea is, however, not fully explored. In this study, RNA-seq analyses identified a set of 29 ncRNA transcripts in the hyperthermophilic archaeon Sulfolobus acidocaldarius that were differentially expressed in response to biofilm formation. The most abundant ncRNA of this set was found to be resistant to RNase R treatment (RNase R resistant RNA, RrrR(+)) due to duplex formation with a reverse complementary RNA (RrrR(-)). The deletion of the RrrR(+) gene resulted in significantly impaired biofilm formation, while its overproduction increased biofilm yield. RrrR(+) was found to act as an antisense RNA against the mRNA of a hypothetical membrane protein. The RrrR(+) transcript was shown to be stabilized by the presence of the RrrR(-) strand in S. acidocaldarius cell extracts. The accumulation of these RrrR duplexes correlates with an apparent absence of dsRNA degrading RNase III domains in archaeal proteins.

  6. Transversal Clifford gates on folded surface codes

    DOE PAGES

    Moussa, Jonathan E.

    2016-10-12

    Surface and color codes are two forms of topological quantum error correction in two spatial dimensions with complementary properties. Surface codes have lower-depth error detection circuits and well-developed decoders to interpret and correct errors, while color codes have transversal Clifford gates and better code efficiency in the number of physical qubits needed to achieve a given code distance. A formal equivalence exists between color codes and folded surface codes, but it does not guarantee the transferability of any of these favorable properties. However, the equivalence does imply the existence of constant-depth circuit implementations of logical Clifford gates on folded surfacemore » codes. We achieve and improve this result by constructing two families of folded surface codes with transversal Clifford gates. This construction is presented generally for qudits of any dimension. Lastly, the specific application of these codes to universal quantum computation based on qubit fusion is also discussed.« less

  7. Redundant Coding in Visual Search Displays: Effects of Shape and Colour.

    DTIC Science & Technology

    1997-02-01

    results for refining color selection algorithms and for color coding in situations where the gamut of available colors is limited. In a secondary set of analyses, we note large performance differences as a function of target shape.

  8. [Malignant and benign diseases of the breast in 41 male patients: mammography, sonography and pathohistological correlations].

    PubMed

    Partik, B; Mallek, R; Rudas, M; Pokieser, P; Wunderbaldinger, P; Helbich, T H

    2001-11-01

    The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS(R) classification. Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92 %, 89 %, 80 %, 96 % and 90 %, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2 % (2/11) of suspicious lesions. In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence.

  9. Visual search asymmetries within color-coded and intensity-coded displays.

    PubMed

    Yamani, Yusuke; McCarley, Jason S

    2010-06-01

    Color and intensity coding provide perceptual cues to segregate categories of objects within a visual display, allowing operators to search more efficiently for needed information. Even within a perceptually distinct subset of display elements, however, it may often be useful to prioritize items representing urgent or task-critical information. The design of symbology to produce search asymmetries (Treisman & Souther, 1985) offers a potential technique for doing this, but it is not obvious from existing models of search that an asymmetry observed in the absence of extraneous visual stimuli will persist within a complex color- or intensity-coded display. To address this issue, in the current study we measured the strength of a visual search asymmetry within displays containing color- or intensity-coded extraneous items. The asymmetry persisted strongly in the presence of extraneous items that were drawn in a different color (Experiment 1) or a lower contrast (Experiment 2) than the search-relevant items, with the targets favored by the search asymmetry producing highly efficient search. The asymmetry was attenuated but not eliminated when extraneous items were drawn in a higher contrast than search-relevant items (Experiment 3). Results imply that the coding of symbology to exploit visual search asymmetries can facilitate visual search for high-priority items even within color- or intensity-coded displays. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  10. Re-design of apple pia packaging using quality function deployment method

    NASA Astrophysics Data System (ADS)

    Pulungan, M. H.; Nadira, N.; Dewi, I. A.

    2018-03-01

    This study was aimed to identify the attributes for premium apple pia packaging, to determine the technical response to be carried out by Permata Agro Mandiri Small and Medium Enterprise (SME) and to design a new apple pie packaging acceptable by the SME. The Quality Function Deployment (QFD) method was employed to improve the apple pia packaging design, which consisted of seven stages in data analysis. The results indicated that whats attribute required by the costumers include graphic design, dimensions, capacity, shape, strength, and resistance of packaging. While, the technical responses to be conducted by the SMEs were as follows: attractive visual packaging designs, attractive colors, clear images and information, packaging size dimensions, a larger capacity packaging (more product content), ergonomic premium packaging, not easily torn, and impact resistant packaging materials. The findings further confirmed that the design of premium apple pia packaging accepted by the SMES was the one with the capacity of ten apple pia or 200 g weight, and with rectangular or beam shape form. The packaging material used was a duplex carton with 400 grammage (g/m2), the outer part of the packaging was coated with plastic and the inside was added with duplex carton. The acceptable packaging dimension was 30 cm x 5 cm x 3 cm (L x W x H) with a mix of black and yellow color in the graphical design.

  11. A volcanic activity alert-level system for aviation: Review of its development and application in Alaska

    USGS Publications Warehouse

    Guffanti, Marianne C.; Miller, Thomas

    2013-01-01

    An alert-level system for communicating volcano hazard information to the aviation industry was devised by the Alaska Volcano Observatory (AVO) during the 1989–1990 eruption of Redoubt Volcano. The system uses a simple, color-coded ranking that focuses on volcanic ash emissions: Green—normal background; Yellow—signs of unrest; Orange—precursory unrest or minor ash eruption; Red—major ash eruption imminent or underway. The color code has been successfully applied on a regional scale in Alaska for a sustained period. During 2002–2011, elevated color codes were assigned by AVO to 13 volcanoes, eight of which erupted; for that decade, one or more Alaskan volcanoes were at Yellow on 67 % of days and at Orange or Red on 12 % of days. As evidence of its utility, the color code system is integrated into procedures of agencies responsible for air-traffic management and aviation meteorology in Alaska. Furthermore, it is endorsed as a key part of globally coordinated protocols established by the International Civil Aviation Organization to provide warnings of ash hazards to aviation worldwide. The color code and accompanying structured message (called a Volcano Observatory Notice for Aviation) comprise an effective early-warning message system according to the United Nations International Strategy for Disaster Reduction. The aviation color code system currently is used in the United States, Russia, New Zealand, Iceland, and partially in the Philippines, Papua New Guinea, and Indonesia. Although there are some barriers to implementation, with continued education and outreach to Volcano Observatories worldwide, greater use of the aviation color code system is achievable.

  12. A volcanic activity alert-level system for aviation: review of its development and application in Alaska

    USGS Publications Warehouse

    Guffanti, Marianne; Miller, Thomas P.

    2013-01-01

    An alert-level system for communicating volcano hazard information to the aviation industry was devised by the Alaska Volcano Observatory (AVO) during the 1989–1990 eruption of Redoubt Volcano. The system uses a simple, color-coded ranking that focuses on volcanic ash emissions: Green—normal background; Yellow—signs of unrest; Orange—precursory unrest or minor ash eruption; Red—major ash eruption imminent or underway. The color code has been successfully applied on a regional scale in Alaska for a sustained period. During 2002–2011, elevated color codes were assigned by AVO to 13 volcanoes, eight of which erupted; for that decade, one or more Alaskan volcanoes were at Yellow on 67 % of days and at Orange or Red on 12 % of days. As evidence of its utility, the color code system is integrated into procedures of agencies responsible for air-traffic management and aviation meteorology in Alaska. Furthermore, it is endorsed as a key part of globally coordinated protocols established by the International Civil Aviation Organization to provide warnings of ash hazards to aviation worldwide. The color code and accompanying structured message (called a Volcano Observatory Notice for Aviation) comprise an effective early-warning message system according to the United Nations International Strategy for Disaster Reduction. The aviation color code system currently is used in the United States, Russia, New Zealand, Iceland, and partially in the Philippines, Papua New Guinea, and Indonesia. Although there are some barriers to implementation, with continued education and outreach to Volcano Observatories worldwide, greater use of the aviation color code system is achievable.

  13. Transcutaneous bowel sonography for inflammatory bowel disease is sensitive and specific when performed in a nonexpert low-volume North American center.

    PubMed

    Sey, Michael Sai Lai; Gregor, Jamie; Chande, Nilesh; Ponich, Terry; Bhaduri, Mousumi; Lum, Andrea; Zaleski, Witek; Yan, Brian

    2013-08-01

    Transcutaneous bowel sonography is a nonionizing imaging modality used in inflammatory bowel disease. Although available in Europe, its uptake in North America has been limited. Since the accuracy of bowel sonography is highly operator dependent, low-volume centers in North America may not achieve the same diagnostic accuracy reported in the European literature. Our objective was to determine the diagnostic accuracy of bowel sonography in a nonexpert low-volume center. All cases of bowel sonography at a single tertiary care center during an 18-month period were reviewed. Bowel sonography was compared with reference standards, including small-bowel follow-through, computed tomography, magnetic resonance imaging, colonoscopy, and surgical findings. A total of 103 cases were included for analysis during the study period. The final diagnoses included Crohn disease (72), ulcerative colitis (8), hemolytic uremic syndrome (1), and normal (22). The sensitivity and specificity of bowel sonography for intestinal wall inflammation were 87.8% and 92.6%, respectively. In the subset of patients who had complications of Crohn disease, the sensitivity and specificity were 50% and 100% for fistulas and 14% and 100% for strictures. One patient had an abscess, which was detected by bowel sonography. Abnormal bowel sonographic findings contributed to the escalation of treatment in 55% of cases. Bowel sonography for inflammatory bowel disease can be performed in low-volume centers and provides diagnostic accuracy for luminal disease comparable with published data, although it is less sensitive for complications of Crohn disease.

  14. Prenatal Diagnosis of Placenta Accreta: Sonography or Magnetic Resonance Imaging?

    PubMed Central

    Dwyer, Bonnie K.; Belogolovkin, Victoria; Tran, Lan; Rao, Anjali; Carroll, Ian; Barth, Richard; Chitkara, Usha

    2009-01-01

    Objective The purpose of this study was to compare the accuracy of transabdominal sonography and magnetic resonance imaging (MRI) for prenatal diagnosis of placenta accreta. Methods A historical cohort study was undertaken at 3 institutions identifying women at risk for placenta accreta who had undergone both sonography and MRI prenatally. Sonographic and MRI findings were compared with the final diagnosis as determined at delivery and by pathologic examination. Results Thirty-two patients who had both sonography and MRI prenatally to evaluate for placenta accreta were identified. Of these, 15 had confirmation of placenta accreta at delivery. Sonography correctly identified the presence of placenta accreta in 14 of 15 patients (93% sensitivity; 95% confidence interval [CI], 80%–100%) and the absence of placenta accreta in 12 of 17 patients (71% specificity; 95% CI, 49%–93%). Magnetic resonance imaging correctly identified the presence of placenta accreta in 12 of 15 patients (80% sensitivity; 95% CI, 60%–100%) and the absence of placenta accreta in 11 of 17 patients (65% specificity; 95% CI, 42%–88%). In 7 of 32 cases, sonography and MRI had discordant diagnoses: sonography was correct in 5 cases, and MRI was correct in 2. There was no statistical difference in sensitivity (P = .25) or specificity (P = .5) between sonography and MRI. Conclusions Both sonography and MRI have fairly good sensitivity for prenatal diagnosis of placenta accreta; however, specificity does not appear to be as good as reported in other studies. In the case of inconclusive findings with one imaging modality, the other modality may be useful for clarifying the diagnosis. PMID:18716136

  15. Topology-selective jamming of fully-connected, code-division random-access networks

    NASA Technical Reports Server (NTRS)

    Polydoros, Andreas; Cheng, Unjeng

    1990-01-01

    The purpose is to introduce certain models of topology selective stochastic jamming and examine its impact on a class of fully-connected, spread-spectrum, slotted ALOHA-type random access networks. The theory covers dedicated as well as half-duplex units. The dominant role of the spatial duty factor is established, and connections with the dual concept of time selective jamming are discussed. The optimal choices of coding rate and link access parameters (from the users' side) and the jamming spatial fraction are numerically established for DS and FH spreading.

  16. Robust Modulo Remaindering and Applications in Radar and Sensor Signal Processing

    DTIC Science & Technology

    2015-08-27

    Chinese Remainder Theorem in FDD Systems, Science China -- Information Sciences, vol.55, no.7, pp. 1605 -1616, July 2012. 3) Y. Liu, X.-G. Xia, and H. L...Sciences, vol.55, no.7, pp. 1605 -1616, July 2012. 3) Y. Liu, X.-G. Xia, and H. L. Zhang, Distributed Space-Time Coding for Full-DuplexAsynchronous

  17. Sonography in the 29th Olympic and Paralympic Games: a retrospective analysis.

    PubMed

    He, Wen; Xiang, Dong-ying; Dai, Jian-ping

    2011-01-01

    The purpose of this study was to evaluate the application of sonography at the polyclinic of the Olympic/Paralympic village during the Olympic/Paralympic Games. We retrospectively reviewed 759 consecutive patients who underwent sonography at the ultrasound division of the polyclinic in the Olympic/Paralympic village from July 20, 2008, to September 20, 2008. Prevalence of emergency sonography after sports injury and non-sports-related urgent conditions during the games was analyzed. The benefit of sonographic services in large sporting events was discussed. There were 759 patients (484 athletes, 101 coaches, 88 team officials, and 86 volunteers; 462 men and 297 women) in the ultrasound division at the polyclinic. The indications for sonography included abdominal pain (315 cases, 41.50%), muskuloskeletal disorders (228 cases, 30.04%), gynecology related (104 cases, 13.70%), cardiac conditions (49 cases, 6.46%), small parts (29 cases, 3.82%), and vascular problems (34 cases, 4.48%). The rates of positive findings on sonography were 46.03% in the abdomen, 70.17% in musculoskeleton, 41.34% in gynecology, 10.20% in the heart, 75.86% in small parts, and 38.24% in vessels, respectively. Sonography plays an important role in the medical services at the polyclinic in the Olympic/Paralympic village. The benefits of sonography in such large sporting events are accuracy, fast result, portability, and noninvasiveness. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Use of fluorescent proteins and color-coded imaging to visualize cancer cells with different genetic properties.

    PubMed

    Hoffman, Robert M

    2016-03-01

    Fluorescent proteins are very bright and available in spectrally-distinct colors, enable the imaging of color-coded cancer cells growing in vivo and therefore the distinction of cancer cells with different genetic properties. Non-invasive and intravital imaging of cancer cells with fluorescent proteins allows the visualization of distinct genetic variants of cancer cells down to the cellular level in vivo. Cancer cells with increased or decreased ability to metastasize can be distinguished in vivo. Gene exchange in vivo which enables low metastatic cancer cells to convert to high metastatic can be color-coded imaged in vivo. Cancer stem-like and non-stem cells can be distinguished in vivo by color-coded imaging. These properties also demonstrate the vast superiority of imaging cancer cells in vivo with fluorescent proteins over photon counting of luciferase-labeled cancer cells.

  19. Reimbursement Policies for Carotid Duplex Ultrasound that are Based on International Classification of Diseases Codes May Discourage Testing in High-Yield Groups.

    PubMed

    Go, Michael R; Masterson, Loren; Veerman, Brent; Satiani, Bhagwan

    2016-02-01

    To curb increasing volumes of diagnostic imaging and costs, reimbursement for carotid duplex ultrasound (CDU) is dependent on "appropriate" indications as documented by International Classification of Diseases (ICD) codes entered by ordering physicians. Historically, asymptomatic indications for CDU yield lower rates of abnormal results than symptomatic indications, and consensus documents agree that most asymptomatic indications for CDU are inappropriate. In our vascular laboratory, we perceived an increased rate of incorrect or inappropriate ICD codes. We therefore sought to determine if ICD codes were useful in predicting the frequency of abnormal CDU. We hypothesized that asymptomatic or nonspecific ICD codes would yield a lower rate of abnormal CDU than symptomatic codes, validating efforts to limit reimbursement in asymptomatic, low-yield groups. We reviewed all outpatient CDU done in 2011 at our institution. ICD codes were recorded, and each medical record was then reviewed by a vascular surgeon to determine if the assigned ICD code appropriately reflected the clinical scenario. CDU findings categorized as abnormal (>50% stenosis) or normal (<50% stenosis) were recorded. Each individual ICD code and group 1 (asymptomatic), group 2 (nonhemispheric symptoms), group 3 (hemispheric symptoms), group 4 (preoperative cardiovascular examination), and group 5 (nonspecific) ICD codes were analyzed for correlation with CDU results. Nine hundred ninety-four patients had 74 primary ICD codes listed as indications for CDU. Of assigned ICD codes, 17.4% were deemed inaccurate. Overall, 14.8% of CDU were abnormal. Of the 13 highest frequency ICD codes, only 433.10, an asymptomatic code, was associated with abnormal CDU. Four symptomatic codes were associated with normal CDU; none of the other high frequency codes were associated with CDU result. Patients in group 1 (asymptomatic) were significantly more likely to have an abnormal CDU compared to each of the other groups (P < 0.001, P < 0.001, P = 0.020, P = 0.002) and to all other groups combined (P < 0.001). Asymptomatic indications by ICD codes yielded higher rates of abnormal CDU than symptomatic indications. This finding is inconsistent with clinical experience and historical data, and we suggest that inaccurate coding may play a role. Limiting reimbursement for CDU in low-yield groups is reasonable. However, reimbursement policies based on ICD coding, for example, limiting payment for asymptomatic ICD codes, may impede use of CDU in high-yield patient groups. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Perforated pyloroduodenal peptic ulcer and sonography.

    PubMed

    Kuzmich, Siarhei; Harvey, Chris J; Fascia, Daniel T M; Kuzmich, Tatsiana; Neriman, Deena; Basit, Rizwan; Tan, Kai Lee

    2012-11-01

    The purpose of this article is to illustrate the spectrum of sonographic findings in perforated pyloroduodenal peptic ulcer and discuss the potential role of sonography in the diagnosis. Although sonography is not the first-line investigation of choice in suspected perforated peptic ulcer, understanding of the characteristic appearances seen during general abdominal sonography may aid the reader in the diagnosis of this important and sometimes overlooked cause of nonspecific abdominal pain. This may shorten time to the diagnosis and ultimate surgical management.

  1. Quantum computing with Majorana fermion codes

    NASA Astrophysics Data System (ADS)

    Litinski, Daniel; von Oppen, Felix

    2018-05-01

    We establish a unified framework for Majorana-based fault-tolerant quantum computation with Majorana surface codes and Majorana color codes. All logical Clifford gates are implemented with zero-time overhead. This is done by introducing a protocol for Pauli product measurements with tetrons and hexons which only requires local 4-Majorana parity measurements. An analogous protocol is used in the fault-tolerant setting, where tetrons and hexons are replaced by Majorana surface code patches, and parity measurements are replaced by lattice surgery, still only requiring local few-Majorana parity measurements. To this end, we discuss twist defects in Majorana fermion surface codes and adapt the technique of twist-based lattice surgery to fermionic codes. Moreover, we propose a family of codes that we refer to as Majorana color codes, which are obtained by concatenating Majorana surface codes with small Majorana fermion codes. Majorana surface and color codes can be used to decrease the space overhead and stabilizer weight compared to their bosonic counterparts.

  2. 29 CFR 1910.144 - Safety color code for marking physical hazards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii... 29 Labor 5 2011-07-01 2011-07-01 false Safety color code for marking physical hazards. 1910.144 Section 1910.144 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH...

  3. Cryotherapy of Renal Lesions: Enhancement on Contrast-Enhanced Sonography on Postoperative Day 1 Does Not Imply Viable Tissue Persistence.

    PubMed

    Bertolotto, Michele; Siracusano, Salvatore; Cicero, Calogero; Iannelli, Mariano; Silvestri, Tommaso; Celia, Antonio; Guarise, Alessandro; Stacul, Fulvio

    2017-02-01

    To investigate whether persistent enhancement detected on contrast-enhanced sonography at postoperative day 1 (early contrast-enhanced sonography) after cryoablation of renal tumors implies the presence of residual viable tumor tissue, defined as residual enhancing tissue on reference imaging (computed tomography or magnetic resonance imaging) performed 6 months after the procedure. Seventy-four patients with percutaneous cryoablation of renal tumors had early contrast-enhanced sonography from November 2011 to August 2015. Two independent readers evaluated early contrast-enhanced sonographic findings and contrast-enhanced sonographic investigations performed 1 month after cryoablation of lesions that displayed enhancement on early contrast-enhanced sonography. They scored intralesional enhancement in 4 groups: no enhancement, few intralesional vessels, focal enhancing areas, and diffuse enhancement. Inter-reader agreement in evaluating lesion vascularity on early contrast-enhanced sonography was assessed with weighted κ statistics. Computed tomography or magnetic resonance imaging performed 6 months after the treatment was the reference procedure for assessing the absence or presence of residual disease. Inter-reader agreement in assessing intratumoral vascularization on early contrast-enhanced sonography was very good (κ = 0.90). Enhancement was absent for both readers in 33 of 74 cases; only a few intralesional vessels were visible in 21; whereas diffuse or focal enhancement was present in 13. In the remaining 7 patients, there were differences. Four lesions with focal enhancement on early contrast-enhanced sonography and 1 that was considered avascular had residual tumors on reference imaging. Ablation was successful in the remaining 69 of 74 patients (93%). After cryoablation, intratumoral enhancement on early contrast-enhanced sonography does not imply tumor cell viability. © 2016 by the American Institute of Ultrasound in Medicine.

  4. Collateral circulation on perfusion-computed tomography-source images predicts the response to stroke intravenous thrombolysis.

    PubMed

    Calleja, A I; Cortijo, E; García-Bermejo, P; Gómez, R D; Pérez-Fernández, S; Del Monte, J M; Muñoz, M F; Fernández-Herranz, R; Arenillas, J F

    2013-05-01

    Perfusion-computed tomography-source images (PCT-SI) may allow a dynamic assessment of leptomeningeal collateral arteries (LMC) filling and emptying in middle cerebral artery (MCA) ischaemic stroke. We described a regional LMC scale on PCT-SI and hypothesized that a higher collateral score would predict a better response to intravenous (iv) thrombolysis. We studied consecutive ischaemic stroke patients with an acute MCA occlusion documented by transcranial Doppler/transcranial color-coded duplex, treated with iv thrombolysis who underwent PCT prior to treatment. Readers evaluated PCT-SI in a blinded fashion to assess LMC within the hypoperfused MCA territory. LMC scored as follows: 0, absence of vessels; 1, collateral supply filling ≤ 50%; 2, between> 50% and < 100%; 3, equal or more prominent when compared with the unaffected hemisphere. The scale was divided into good (scores 2-3) vs. poor (scores 0-1) collaterals. The predetermined primary end-point was a good 3-month functional outcome, while early neurological recovery, transcranial duplex-assessed 24-h MCA recanalization, 24-h hypodensity volume and hemorrhagic transformation were considered secondary end-points. Fifty-four patients were included (55.5% women, median NIHSS 10), and 4-13-23-14 patients had LMC score (LMCs) of 0-1-2-3, respectively. The probability of a good long-term outcome augmented gradually with increasing LMCs: (0) 0%; (1) 15.4%; (2) 65.2%; (3) 64.3%, P = 0.004. Good-LMCs was independently associated with a good outcome [OR 21.02 (95% CI 2.23-197.75), P = 0.008]. Patients with good LMCs had better early neurological recovery (P = 0.001), smaller hypodensity volumes (P < 0.001) and a clear trend towards a higher recanalization rate. A higher degree of LMC assessed by PCT-SI predicts good response to iv thrombolysis in MCA ischaemic stroke patients. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  5. Progressive low-bitrate digital color/monochrome image coding by neuro-fuzzy clustering

    NASA Astrophysics Data System (ADS)

    Mitra, Sunanda; Meadows, Steven

    1997-10-01

    Color image coding at low bit rates is an area of research that is just being addressed in recent literature since the problems of storage and transmission of color images are becoming more prominent in many applications. Current trends in image coding exploit the advantage of subband/wavelet decompositions in reducing the complexity in optimal scalar/vector quantizer (SQ/VQ) design. Compression ratios (CRs) of the order of 10:1 to 20:1 with high visual quality have been achieved by using vector quantization of subband decomposed color images in perceptually weighted color spaces. We report the performance of a recently developed adaptive vector quantizer, namely, AFLC-VQ for effective reduction in bit rates while maintaining high visual quality of reconstructed color as well as monochrome images. For 24 bit color images, excellent visual quality is maintained upto a bit rate reduction to approximately 0.48 bpp (for each color plane or monochrome 0.16 bpp, CR 50:1) by using the RGB color space. Further tuning of the AFLC-VQ, and addition of an entropy coder module after the VQ stage results in extremely low bit rates (CR 80:1) for good quality, reconstructed images. Our recent study also reveals that for similar visual quality, RGB color space requires less bits/pixel than either the YIQ, or HIS color space for storing the same information when entropy coding is applied. AFLC-VQ outperforms other standard VQ and adaptive SQ techniques in retaining visual fidelity at similar bit rate reduction.

  6. Influence of Interpretation Aids on Attentional Capture, Visual Processing, and Understanding of Front-of-Package Nutrition Labels.

    PubMed

    Antúnez, Lucía; Giménez, Ana; Maiche, Alejandro; Ares, Gastón

    2015-01-01

    To study the influence of 2 interpretational aids of front-of-package (FOP) nutrition labels (color code and text descriptors) on attentional capture and consumers' understanding of nutritional information. A full factorial design was used to assess the influence of color code and text descriptors using visual search and eye tracking. Ten trained assessors participated in the visual search study and 54 consumers completed the eye-tracking study. In the visual search study, assessors were asked to indicate whether there was a label high in fat within sets of mayonnaise labels with different FOP labels. In the eye-tracking study, assessors answered a set of questions about the nutritional content of labels. The researchers used logistic regression to evaluate the influence of interpretational aids of FOP nutrition labels on the percentage of correct answers. Analyses of variance were used to evaluate the influence of the studied variables on attentional measures and participants' response times. Response times were significantly higher for monochromatic FOP labels compared with color-coded ones (3,225 vs 964 ms; P < .001), which suggests that color codes increase attentional capture. The highest number and duration of fixations and visits were recorded on labels that did not include color codes or text descriptors (P < .05). The lowest percentage of incorrect answers was observed when the nutrient level was indicated using color code and text descriptors (P < .05). The combination of color codes and text descriptors seems to be the most effective alternative to increase attentional capture and understanding of nutritional information. Copyright © 2015 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  7. Normative Database and Color-code Agreement of Peripapillary Retinal Nerve Fiber Layer and Macular Ganglion Cell-inner Plexiform Layer Thickness in a Vietnamese Population.

    PubMed

    Perez, Claudio I; Chansangpetch, Sunee; Thai, Andy; Nguyen, Anh-Hien; Nguyen, Anwell; Mora, Marta; Nguyen, Ngoc; Lin, Shan C

    2018-06-05

    Evaluate the distribution and the color probability codes of the peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy Vietnamese population and compare them with the original color-codes provided by the Cirrus spectral domain OCT. Cross-sectional study. We recruited non-glaucomatous Vietnamese subjects and constructed a normative database for peripapillary RNFL and macular GCIPL thickness. The probability color-codes for each decade of age were calculated. We evaluated the agreement with Kappa coefficient (κ) between OCT color probability codes with Cirrus built-in original normative database and the Vietnamese normative database. 149 eyes of 149 subjects were included. The mean age of enrollees was 60.77 (±11.09) years, with a mean spherical equivalent of +0.65 (±1.58) D and mean axial length of 23.4 (±0.87) mm. Average RNFL thickness was 97.86 (±9.19) microns and average macular GCIPL was 82.49 (±6.09) microns. Agreement between original and adjusted normative database for RNFL was fair for average and inferior quadrant (κ=0.25 and 0.2, respectively); and good for other quadrants (range: κ=0.63-0.73). For macular GCIPL κ agreement ranged between 0.39 and 0.69. After adjusting with the normative Vietnamese database, the percent of yellow and red color-codes increased significantly for peripapillary RNFL thickness. Vietnamese population has a thicker RNFL in comparison with Cirrus normative database. This leads to a poor color-code agreement in average and inferior quadrant between the original and adjusted database. These findings should encourage to create a peripapillary RNFL normative database for each ethnicity.

  8. A distributed code for color in natural scenes derived from center-surround filtered cone signals

    PubMed Central

    Kellner, Christian J.; Wachtler, Thomas

    2013-01-01

    In the retina of trichromatic primates, chromatic information is encoded in an opponent fashion and transmitted to the lateral geniculate nucleus (LGN) and visual cortex via parallel pathways. Chromatic selectivities of neurons in the LGN form two separate clusters, corresponding to two classes of cone opponency. In the visual cortex, however, the chromatic selectivities are more distributed, which is in accordance with a population code for color. Previous studies of cone signals in natural scenes typically found opponent codes with chromatic selectivities corresponding to two directions in color space. Here we investigated how the non-linear spatio-chromatic filtering in the retina influences the encoding of color signals. Cone signals were derived from hyper-spectral images of natural scenes and preprocessed by center-surround filtering and rectification, resulting in parallel ON and OFF channels. Independent Component Analysis (ICA) on these signals yielded a highly sparse code with basis functions that showed spatio-chromatic selectivities. In contrast to previous analyses of linear transformations of cone signals, chromatic selectivities were not restricted to two main chromatic axes, but were more continuously distributed in color space, similar to the population code of color in the early visual cortex. Our results indicate that spatio-chromatic processing in the retina leads to a more distributed and more efficient code for natural scenes. PMID:24098289

  9. Recruitment of Rod Photoreceptors from Short-Wavelength-Sensitive Cones during the Evolution of Nocturnal Vision in Mammals.

    PubMed

    Kim, Jung-Woong; Yang, Hyun-Jin; Oel, Adam Phillip; Brooks, Matthew John; Jia, Li; Plachetzki, David Charles; Li, Wei; Allison, William Ted; Swaroop, Anand

    2016-06-20

    Vertebrate ancestors had only cone-like photoreceptors. The duplex retina evolved in jawless vertebrates with the advent of highly photosensitive rod-like photoreceptors. Despite cones being the arbiters of high-resolution color vision, rods emerged as the dominant photoreceptor in mammals during a nocturnal phase early in their evolution. We investigated the evolutionary and developmental origins of rods in two divergent vertebrate retinas. In mice, we discovered genetic and epigenetic vestiges of short-wavelength cones in developing rods, and cell-lineage tracing validated the genesis of rods from S cones. Curiously, rods did not derive from S cones in zebrafish. Our study illuminates several questions regarding the evolution of duplex retina and supports the hypothesis that, in mammals, the S-cone lineage was recruited via the Maf-family transcription factor NRL to augment rod photoreceptors. We propose that this developmental mechanism allowed the adaptive exploitation of scotopic niches during the nocturnal bottleneck early in mammalian evolution. Published by Elsevier Inc.

  10. Congenital renal arteriovenous fistula during the first trimester diagnosed with ultrasonography.

    PubMed

    Yao, Mengyun; Zhang, Qiuyan; Wang, Jing; Xiang, Feixiang; Yu, Cheng; Lv, Qing; Xie, Mingxing; Zhang, Yanrong

    2017-01-01

    A case of congenital renal arteriovenous fistula (AVF) complicating pregnancy with gross hematuria was managed successfully by superselective embolization with metallic coils. The patient was in the first trimester of her pregnancy at 12 weeks of gestation. The AVF was detected by color Doppler sonography and confirmed by renal arteriography. Because of its easy accessibility and absence of irradiation, ultrasound is the first choice for pregnant patients. Color Doppler ultrasound is effective in diagnosing AVF, and it is also helpful in the long-term followup after treatment. The cirsoid-type renal congenital arteriovenous fistula has a characteristic sonographic appearance with a cluster of tubular anechoic structures in the kidney, which produce continuous turbulent high-velocity flow signals and a burr-like boundary flow spectrum. When the sonographic features are present, the diagnosis of renal AVF should be made, after which renal arteriography can be performed to confirm it. Selective embolization provided a safe and effective treatment with minimal damage to the parenchyma and without compromising renal function.

  11. Role of 3D Ultrasound and Doppler in Differentiating Clinically Suspected Cases of Leiomyoma and Adenomyosis of Uterus

    PubMed Central

    Sharma, Kaveri; Venkatesh, B.P; Barman, Partho; Roy, Sumit Kumar; Jayagurunathan, Usha; Sellamuthu, Eswaramoorthy; Moidu, Fazil

    2015-01-01

    Introduction Adenomyosis and Leiomyoma are common disorders affecting females in their reproductive age. They mimic each other in clinical presentation. Due to similarities in clinical symptoms and signs, missing one diagnosis in favour of the other is not very uncommon. Accurate diagnosis of these two conditions is important for their management. In this study we evaluated role of 3D Ultrasound and Doppler in differentiating clinically suspected cases of leiomyoma and adenomyosis of uterus. Materials and Methods A total of 100 patients with symptoms of abnormal uterine bleeding (with or without dysmenorrhoea), lump abdomen, chronic pelvic pain or dysparaunia who were clinically diagnosed as leiomyoma of uterus and/or adenomyosis were enrolled in to the study. These patients underwent transvaginal sonography (TVS), trans abdominal sonography (TAS) along with color and spectral Doppler sonography. Scanning was done in follicular phase of the menstrual cycle to avoid bias due high vascularity of endometrium in secretory phase. The morphology of the lesion, its vascularity, and Pulsality Index (PI), Resistive Index (RI) and Vmax (maximum velocity) were measured. Only those patients who were chosen for operative treatment were included in the study. Radiological diagnosis was then correlated with intra-operative and histopathological diagnosis. Results On imaging, while using morphological criteria and Doppler for diagnosing leiomyoma, it was found that “peripheral vascularity” was seen in 52 (89%) cases, which was the highest. Similarly while diagnosing adenomyosis it was, the criteria “central vascularity” was seen in 28 cases (93%) and “ill defined junctional zone in 3D ultrasound” was seen in 26 cases (86%), which was also observed to be highest. With the cut off values taken for PI,RI and Vmax, diagnosis of leiomyoma was found to be 93.4% sensitive, 95.6% specific and with a positive predictive value of 97.6% and negative predictive value of 88.6%. Diagnosis of adenomyosis showed a sensitivity of 95.6%, specificity of 93.4% and a positive predictive value of 88.6% and negative predictive value of 97.6%. Imaging dignosed the co-existence of both the conditions correctly in 8 (66%) cases. Conclusion The parameters of blood flow impedance (that is PI, RI, and Vmax) of arteries within or around the uterine lesions revealed a consistent and significant difference between leiomyoma and adenomyosis. So apart from morphological criteria used in 3D TAS and TVS, aid of color Doppler can more accurately differentiate and diagnose these conditions. PMID:26023602

  12. 7 CFR 1755.200 - RUS standard for splicing copper and fiber optic cables.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Color coded plastic tie wraps shall be placed loosely around each binder group of cables before splicing... conform to the same color designations as the binder ribbons. Twisted wire pigtails shall not be used to identify binder groups due to potential transmission degradation. (ii) The standard insulation color code...

  13. Anticounterfeiting Quick Response Code with Emission Color of Invisible Metal-Organic Frameworks as Encoding Information.

    PubMed

    Wang, Yong-Mei; Tian, Xue-Tao; Zhang, Hui; Yang, Zhong-Rui; Yin, Xue-Bo

    2018-06-21

    Counterfeiting is a global epidemic that is compelling the development of new anticounterfeiting strategy. Herein, we report a novel multiple anticounterfeiting encoding strategy of invisible fluorescent quick response (QR) codes with emission color as information storage unit. The strategy requires red, green, and blue (RGB) light-emitting materials for different emission colors as encrypting information, single excitation for all of the emission for practicability, and ultraviolet (UV) excitation for invisibility under daylight. Therefore, RGB light-emitting nanoscale metal-organic frameworks (NMOFs) are designed as inks to construct the colorful light-emitting boxes for information encrypting, while three black vertex boxes were used for positioning. Full-color emissions are obtained by mixing the trichromatic NMOFs inks through inkjet printer. The encrypting information capacity is easily adjusted by the number of light-emitting boxes with the infinite emission colors. The information is decoded with specific excitation light at 275 nm, making the QR codes invisible under daylight. The composition of inks, invisibility, inkjet printing, and the abundant encrypting information all contribute to multiple anticounterfeiting. The proposed QR codes pattern holds great potential for advanced anticounterfeiting.

  14. INVASIVE AND NON-INVASIVE TECHNIQUES FOR DETECTING PORTAL HYPERTENSION AND PREDICTING VARICEAL BLEEDING IN CIRRHOSIS: A REVIEW

    PubMed Central

    Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J

    2016-01-01

    Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal and post-sinusoidal causes. As a consequence, several complications (i.e., ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from nonbleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques. PMID:24328372

  15. Invasive and non-invasive techniques for detecting portal hypertension and predicting variceal bleeding in cirrhosis: a review.

    PubMed

    Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J

    2014-02-01

    Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal, and post-sinusoidal causes. As a consequence, several complications (i.e. ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment, and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from non-bleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography, and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques.

  16. Effects of target and distractor saturations on the cognitive performance of an integrated display interface

    NASA Astrophysics Data System (ADS)

    Xue, Chengqi; Li, Jing; Wang, Haiyan; Niu, Yafeng

    2015-01-01

    Color coding is often used to enhance decision quality in complex man-machine interfaces of integrated display systems. However, people are easily distracted by irrelevant colors and by the numerous data points and complex structures in the interface. Although an increasing number of studies are seriously focusing on the problem of achieving efficient color coding, few are able to determine the effects of target and distractor saturations on cognitive performance. To study the performances of target colors among distractors, a systematic experiment is conducted to assess the influence of high and low saturated targets on cognitive performance, and the affecting extent of different saturated distractors of homogeneous colors on targets. According to the analysis of the reaction time through the non-parametric statistical method, a calculation method of the cognitive performance of each color is proposed. Based on the calculation of the color differences and the accumulation of the reaction times, it is shown that with the different saturated distractors of homogeneous colors, the high saturated yellow targets perform better than the low saturated ones, and the green and blue targets have moderate performances. When searching for a singleton target placed on a black background, the color difference between the target and the distractor should be more than 20Δ E*ab units in the yellow saturation coding, whereas the color difference should be more than 40Δ E*ab units in the blue and green saturation coding. In addition, as regards saturation coding, the influence of the color difference between the target and the background on cognitive performance is greater than that of the color difference between the target and the distractor. Seemingly, the hue attribute determines whether the saturation difference between the target and the distractor affects the cognitive performance. Based on the experimental results, the simulation design of the instrument dials in a flight situation awareness interface is completed and tested. Simulation results show the feasibility of the method of choosing the target and distractor colors, and the proposed research provides the instruction for the color saturation design of the interface.

  17. Prospective study of catheter-related central vein thrombosis in home parenteral nutrition patients with benign disease using serial venous Doppler ultrasound.

    PubMed

    Cuerda, Cristina; Joly, Francisca; Corcos, Olivier; Concejo, Javier; Puiggrós, Carolina; Gil, Carmen; Pironi, Loris

    2016-02-01

    Catheter-related central vein thrombosis (CRVT) is a severe complication of home parenteral nutrition (HPN) that may be clinically manifest or subclinical. The aims of the study were to prospectively investigate the incidence of CRVT in patients on HPN with benign disease and determine the influence of different variables on this complication. A prospective, multicentre, observational study in the Home Artificial Nutrition-Chronic Intestinal Failure ESPEN group was performed. Patients with benign disease starting HPN or already on HPN after the insertion of a new catheter, were recruited and followed up with Color Doppler Duplex Sonography (CDDS) evaluations at baseline, 1 week, 3, 6 and 12 months after catheter insertion. Fisher's exact test was used to calculate the association of different variables (related to the patient, type of catheter, vascular access, insertion method, catheter care and anticoagulant treatment) with CRVT events. Sixty-two patients (31 males, 31 females) aged 50 ± 19 (19-83) years were included and followed for a median 363 days, with an Inter Quartile Range of 180-365 days, and a total of 16,186 catheter-days. Six patients had previous CRVT and 16 had history of thromboembolic disease (pulmonary and mesenteric). Forty one patients were receiving anticoagulant treatment. Fifty two patients had tunneled catheters and 10 implanted ports. Two patients had symptomatic thrombosis at 3 and 12 months of follow-up (2 and 3 weeks after normal routine CDDS evaluation). The incidence of CRVT was 0.045/catheter/year. CRVT was not significantly associated with any of the variables analyzed. The incidence of CRVT in patients on HPN for benign disease followed by CDDS is low in the first year of catheterization. We did not observe any case of asymptomatic CRVT. Based on our data, CDDS seems to have low effectiveness as a screening tool for CRVT in asymptomatic patients on HPN with benign disease. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  18. High-Resolution Crystal Structure of a Silver(I)-RNA Hybrid Duplex Containing Watson-Crick-like C-Silver(I)-C Metallo-Base Pairs.

    PubMed

    Kondo, Jiro; Tada, Yoshinari; Dairaku, Takenori; Saneyoshi, Hisao; Okamoto, Itaru; Tanaka, Yoshiyuki; Ono, Akira

    2015-11-02

    Metallo-base pairs have been extensively studied for applications in nucleic acid-based nanodevices and genetic code expansion. Metallo-base pairs composed of natural nucleobases are attractive because nanodevices containing natural metallo-base pairs can be easily prepared from commercially available sources. Previously, we have reported a crystal structure of a DNA duplex containing T-Hg(II)-T base pairs. Herein, we have determined a high-resolution crystal structure of the second natural metallo-base pair between pyrimidine bases C-Ag(I)-C formed in an RNA duplex. One Ag(I) occupies the center between two cytosines and forms a C-Ag(I)-C base pair through N3-Ag(I)-N3 linear coordination. The C-Ag(I)-C base pair formation does not disturb the standard A-form conformation of RNA. Since the C-Ag(I)-C base pair is structurally similar to the canonical Watson-Crick base pairs, it can be a useful building block for structure-based design and fabrication of nucleic acid-based nanodevices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. An economic evaluation of first-trimester genetic sonography for prenatal detection of Down syndrome.

    PubMed

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T

    1998-04-01

    To determine 1) the diagnostic accuracy requirements of first-trimester genetic sonography from the cost-benefit point of view and 2) the economic impact of first-trimester genetic sonography for the United States on the basis of the accuracy of previously published studies. A cost-benefit equation was developed on the basis of the hypothesis that the cost of chorionic villus sampling (CVS) in pregnant women with advanced maternal age (at least 35 years old) should be at least equal to the cost of genetic sonography with CVS used only for those with abnormal ultrasound results. The components of the equation included the diagnostic accuracy of genetic ultrasound (sensitivity and specificity for detecting Down syndrome), the costs of the CVS package and genetic ultrasound, and the lifetime cost of Down syndrome cases. First-trimester genetic sonography was found to be beneficial if the overall sensitivity for detecting Down syndrome was greater than 70%, and even then, the cost-benefit ratio depended on the corresponding false-positive rate. The required minimum ultrasound sensitivity varied according to the maternal age-specific prevalence of Down syndrome and ranged between 40% (for women 35 years old) to 96% (for women 44 years old). Of eight published cohorts using nuchal translucency thickness for genetic sonography, five had accuracies of genetic ultrasound compatible with net benefits. The benefits of first-trimester genetic sonography depend on its diagnostic accuracy. First-trimester genetic sonography has the potential for annual savings of 22 million dollars in the United States.

  20. Color Doppler sonography and angioscintigraphy in hepatic Hodgkin’s lymphoma

    PubMed Central

    Stojković, Mirjana V; Artiko, Vera M; Radoman, Irena B; Knežević, Slavko J; Lukić, Snezana M; Kerkez, Mirko D; Lekić, Nebojsa S; Antić, Andrija A; Žuvela, Marinko M; Ranković, Vitomir I; Petrović, Milorad N; Šobić, Dragana P; Obradović, Vladimir B

    2009-01-01

    AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin’s hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin’s lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. RESULTS: In the majority of patients, hepatomegaly was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P > 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P < 0.01). HPI was significantly lower in patients with lymphomas than in controls (P < 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin’s hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions. PMID:19598303

  1. Reds, Greens, Yellows Ease the Spelling Blues.

    ERIC Educational Resources Information Center

    Irwin, Virginia

    1971-01-01

    This document reports on a color-coding innovation designed to improve the spelling ability of high school seniors. This color-coded system is based on two assumptions: that color will appeal to the students and that there are three principal reasons for misspelling. Two groups were chosen for the experiments. A basic list of spelling demons was…

  2. Use of Color-Coded Food Photographs for Meal Planning by Adults with Mental Retardation.

    ERIC Educational Resources Information Center

    Gines, Deon J.; And Others

    1990-01-01

    Ten adults with mild mental retardation used color-coded food photographs and meal code cards to plan nutritionally balanced meals. Subjects spent an average of nine minutes to plan three meals. Errors, which were primarily omissions, occurred mostly in food groups requiring four servings daily. (JDD)

  3. Visual Search Asymmetries within Color-Coded and Intensity-Coded Displays

    ERIC Educational Resources Information Center

    Yamani, Yusuke; McCarley, Jason S.

    2010-01-01

    Color and intensity coding provide perceptual cues to segregate categories of objects within a visual display, allowing operators to search more efficiently for needed information. Even within a perceptually distinct subset of display elements, however, it may often be useful to prioritize items representing urgent or task-critical information.…

  4. 78 FR 59265 - FD&C Yellow No. 5; Exemption From the Requirement of a Tolerance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... (NAICS code 112). Food manufacturing (NAICS code 311). Pesticide manufacturing (NAICS code 32532). B. How.... 5 is a FDA permanently listed color additive used in food, drugs and cosmetics, including drugs and cosmetics for the eye area. FDA's color additive evaluation included the consideration of an extensive set...

  5. A Coded Structured Light System Based on Primary Color Stripe Projection and Monochrome Imaging

    PubMed Central

    Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano

    2013-01-01

    Coded Structured Light techniques represent one of the most attractive research areas within the field of optical metrology. The coding procedures are typically based on projecting either a single pattern or a temporal sequence of patterns to provide 3D surface data. In this context, multi-slit or stripe colored patterns may be used with the aim of reducing the number of projected images. However, color imaging sensors require the use of calibration procedures to address crosstalk effects between different channels and to reduce the chromatic aberrations. In this paper, a Coded Structured Light system has been developed by integrating a color stripe projector and a monochrome camera. A discrete coding method, which combines spatial and temporal information, is generated by sequentially projecting and acquiring a small set of fringe patterns. The method allows the concurrent measurement of geometrical and chromatic data by exploiting the benefits of using a monochrome camera. The proposed methodology has been validated by measuring nominal primitive geometries and free-form shapes. The experimental results have been compared with those obtained by using a time-multiplexing gray code strategy. PMID:24129018

  6. A coded structured light system based on primary color stripe projection and monochrome imaging.

    PubMed

    Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano

    2013-10-14

    Coded Structured Light techniques represent one of the most attractive research areas within the field of optical metrology. The coding procedures are typically based on projecting either a single pattern or a temporal sequence of patterns to provide 3D surface data. In this context, multi-slit or stripe colored patterns may be used with the aim of reducing the number of projected images. However, color imaging sensors require the use of calibration procedures to address crosstalk effects between different channels and to reduce the chromatic aberrations. In this paper, a Coded Structured Light system has been developed by integrating a color stripe projector and a monochrome camera. A discrete coding method, which combines spatial and temporal information, is generated by sequentially projecting and acquiring a small set of fringe patterns. The method allows the concurrent measurement of geometrical and chromatic data by exploiting the benefits of using a monochrome camera. The proposed methodology has been validated by measuring nominal primitive geometries and free-form shapes. The experimental results have been compared with those obtained by using a time-multiplexing gray code strategy.

  7. Contribution of tridimensional sonography and magnetic resonance imaging to prenatal diagnosis of Apert syndrome at mid-trimester.

    PubMed

    Boog, G; Le Vaillant, C; Winer, N; David, A; Quere, M P; Nomballais, M F

    1999-01-01

    A diagnosis of Apert syndrome, suspected at 24 weeks' gestation after conventional sonography showing turribrachycephaly and syndactyly of hands and feet, was confirmed at 26 weeks' gestation by tridimensional sonography and magnetic resonance imaging. This is only the second prenatal diagnosis reported at mid-trimester, excluding cases published from affected mothers or in connection with a context of recurrence. Additional findings have been collected from tridimensional sonography (mid-facial hypoplasia, downslanting palpebral fissures) and from magnetic resonance imaging (verticalization of the clivus and flattened angle of the cranial base).

  8. Not all ultrasounds are created equal: general sonography versus musculoskeletal sonography in the detection of rotator cuff tears

    PubMed Central

    Cole, Brandi; Twibill, Kristen; Lam, Patrick; Hackett, Lisa

    2016-01-01

    Background This cross-sectional analytic diagnostic accuracy study was designed to compare the accuracy of ultrasound performed by general sonographers in local radiology practices with ultrasound performed by an experienced musculoskeletal sonographer for the detection of rotator cuff tears. Methods In total, 238 patients undergoing arthroscopy who had previously had an ultrasound performed by both a general sonographer and a specialist musculoskeletal sonographer made up the study cohort. Accuracy of diagnosis was compared with the findings at arthroscopy. Results When analyzed as all tears versus no tears, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 95%, whereas general sonography had an accuracy of 91%, a sensitivity of 91% and a specificity of 86%. When the partial tears were split with those ≥ 50% thickness in the tear group and those < 50% thickness in the no-tear group, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 100% and general sonography had an accuracy of 85%, a sensitivity of 84% and a specificity of 87%. Conclusions Ultrasound in the hands of an experienced musculoskeletal sonographer is highly accurate for the diagnosis of rotator cuff tears. General sonography has improved subsequent to earlier studies but remains inferior to an ultrasound performed by a musculoskeletal sonographer. PMID:27660657

  9. Age-related variations of varicose veins anatomy.

    PubMed

    Caggiati, Alberto; Rosi, Caterina; Heyn, Rosemarie; Franceschini, Marco; Acconcia, Maria Cristina

    2006-12-01

    Primary varicose veins are commonly considered a progressive disease starting from the saphenous junctions and extending to tributaries in a retrograde fashion along the saphenous trunks. This theory has been criticized by studies indicating different patterns of development and progression of varicose veins. To contribute to the understanding of the pathogenesis of the disease, the anatomy of the venous bed was comparatively evaluated by duplex sonography in patients with varicose veins with a marked difference in age. The study included 100 varicose limbs in 82 patients aged < 30 years and 238 limbs in 183 patients aged > 60 years. Veins were designated as saphenous veins (SVs), tributaries of the SVs (STVs), and veins not connected with the SVs (NSVs). Four main anatomic patterns were comparatively evaluated: (1) varicose changes only along SVs, (2) varicose changes along SVs and STVs, (3) varicose changes only in STVs, and (4) varicose changes only in NSVs. SVs were normal in 44% of varicose limbs. In most limbs from young subjects, varicose changes afflicted only SVTs (25%) and NSVs (36%). Varicose SVs were more frequent in the older group (62%) than in younger one (39%) owing to a higher prevalence of limbs with combined SV and STV varicosities (respectively, 59% and 37%). In the older group, varicosities in the STVs were more frequently observed in association with incompetence of the SV trunks. The frequent occurrence of normal SVs in varicose limbs of all patients does not support the crucial role commonly credited to SVs in the pathogenesis of primary varicosities. Moreover, the SV trunks were normal in most varicose limbs from young patients. These findings suggest that varicose disease may progressively extend in an antegrade fashion, spreading from the STVs to the SVs. This hypothesis suggests that the saphenous trunks could be spared in the treatment of a relevant number of varicose legs. Prospective longitudinal studies with serial duplex evaluations of large series of extremities are necessary to confirm this hypothesis.

  10. Sonography for diagnosis of benign and malignant tumors of the nose and paranasal sinuses.

    PubMed

    Liu, Jun-jie; Gao, Yong; Wu, Ya-Fei; Zhu, Shang-Yong

    2014-09-01

    The purpose of this study was to demonstrate the reliability of sonography for diagnosis of nose and paranasal sinus tumors. Ninety-six consecutive patients with tumors underwent sonography and computed tomography (CT) before surgical treatment. Tumor detectability and imaging findings were evaluated independently and then compared with pathologic findings. Of 96 tumors, 75 were detected by sonography, for a detectability rate of 78.1%; 93 tumors were detected by CT, for a detectability rate of 96.9%. By comparison, sonography showed a trend toward higher detectability of nasal vestibular tumors than CT (87.5% for sonography versus 50.0% for CT) and small lumps on the wing of the nose (78.8% for sonography versus 33.3% for CT). Among the sonographic features, boundary, shape, internal echo, calcification, bone invasion, vascular pattern, and cervical lymph node metastasis all had significantly positive correlations with malignancy (P < .05), but size did not (P = .324). In addition, the vascular resistive index for malignant tumors was significantly higher (mean ± SD, 0.66 ± 0.20) than the index for benign lesions (0.24 ± 0.30; P < .001). Moreover, the detection rate for grade 1-3 (small-large) blood flow in benign lesions was only 43.8%, whereas the rate for malignant tumors was 97.7% (P < .001). The vascular pattern may be a promising predictive indicator for distinguishing benign and malignant tumors of the nose and paranasal sinuses. Consequently, sonography has high value for diagnosis of benign and malignant tumors of the nose and paranasal sinuses, especially for nasal vestibular tumors and small lumps on the wing of the nose. © 2014 by the American Institute of Ultrasound in Medicine.

  11. Diagnostic efficacy of contrast-enhanced sonography by combined qualitative and quantitative analysis in breast lesions: a comparative study with magnetic resonance imaging.

    PubMed

    Wang, Lin; Du, Jing; Li, Feng-Hua; Fang, Hua; Hua, Jia; Wan, Cai-Feng

    2013-10-01

    The purpose of this study was to evaluate the diagnostic efficacy of contrast-enhanced sonography for differentiation of breast lesions by combined qualitative and quantitative analyses in comparison to magnetic resonance imaging (MRI). Fifty-six patients with American College of Radiology Breast Imaging Reporting and Data System category 3 to 5 breast lesions on conventional sonography were evaluated by contrast-enhanced sonography and MRI. A comparative analysis of diagnostic results between contrast-enhanced sonography and MRI was conducted in light of the pathologic findings. Pathologic analysis showed 26 benign and 30 malignant lesions. The predominant enhancement patterns of the benign lesions on contrast-enhanced sonography were homogeneous, centrifugal, and isoenhancement or hypoenhancement, whereas the patterns of the malignant lesions were mainly heterogeneous, centripetal, and hyperenhancement. The detection rates for perfusion defects and peripheral radial vessels in the malignant group were much higher than those in the benign group (P < .05). As to quantitative analysis, statistically significant differences were found in peak and time-to-peak values between the groups (P < .05). With pathologic findings as the reference standard, the sensitivity, specificity, and accuracy of contrast-enhanced sonography and MRI were 90.0%, 92.3%, 91.1% and 96.7%, 88.5%, and 92.9%, respectively. The two methods had a concordant rate of 87.5% (49 of 56), and the concordance test gave a value of κ = 0.75, indicating that there was high concordance in breast lesion assessment between the two diagnostic modalities. Contrast-enhanced sonography provided typical enhancement patterns and valuable quantitative parameters, which showed good agreement with MRI in diagnostic efficacy and may potentially improve characterization of breast lesions.

  12. New Skeletal-Space-Filling Models

    ERIC Educational Resources Information Center

    Clarke, Frank H.

    1977-01-01

    Describes plastic, skeletal molecular models that are color-coded and can illustrate both the conformation and overall shape of small molecules. They can also be converted to space-filling counterparts by the additions of color-coded polystyrene spheres. (MLH)

  13. How to identify up to 30 colors without training: color concept retrieval by free color naming

    NASA Astrophysics Data System (ADS)

    Derefeldt, Gunilla A. M.; Swartling, Tiina

    1994-05-01

    Used as a redundant code, color is shown to be advantageous in visual search tasks. It enhances attention, detection, and recall of information. Neuropsychological and neurophysiological findings have shown color and spatial perception to be interrelated functions. Studies on eye movements show that colored symbols are easier to detect and that eye fixations are more correctly directed to color-coded symbols. Usually between 5 and 15 colors have been found useful in classification tasks, but this umber can be increased to between 20 to 30 by careful selection of colors, and by a subject's practice with the identification task and familiarity with the particular colors. Recent neurophysiological findings concerning the language-concept connection in color suggest that color concept retrieval would be enhanced by free color naming or by the use of natural associations between color concepts and color words. To test this hypothesis, we had subjects give their own free associations to a set of 35 colors presented on a display. They were able to identify as many as 30 colors without training.

  14. A color-coded vision scheme for robotics

    NASA Technical Reports Server (NTRS)

    Johnson, Kelley Tina

    1991-01-01

    Most vision systems for robotic applications rely entirely on the extraction of information from gray-level images. Humans, however, regularly depend on color to discriminate between objects. Therefore, the inclusion of color in a robot vision system seems a natural extension of the existing gray-level capabilities. A method for robot object recognition using a color-coding classification scheme is discussed. The scheme is based on an algebraic system in which a two-dimensional color image is represented as a polynomial of two variables. The system is then used to find the color contour of objects. In a controlled environment, such as that of the in-orbit space station, a particular class of objects can thus be quickly recognized by its color.

  15. Postmenopausal bleeding: value of imaging.

    PubMed

    Reinhold, Caroline; Khalili, Ida

    2002-05-01

    Endovaginal sonography in combination with HSG is an effective screening tool in evaluating patients with postmenopausal bleeding. Endovaginal sonography is highly sensitive for detecting endometrial carcinoma and can identify patients at low risk for endometrial disease obviating the need for endometrial sampling in this subgroup of patients. In patients with abnormal findings at sonography, a detailed morphologic analysis can be used to determine which patients can undergo blind endometrial sampling successfully versus those who would benefit from hysteroscopic guidance. In patients in whom endovaginal sonography and HSG are inadequate, MRI may provide additional information on the appearance of the endometrium, particularly in patients in whom endometrial sampling is difficult (eg, patients with cervical stenosis).

  16. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips

    PubMed Central

    Schulz-Wendtland, R.; Dankerl, P.; Dilbat, G.; Bani, M.; Fasching, P. A.; Heusinger, K.; Lux, M. P.; Loehberg, C. R.; Jud, S. M.; Rauh, C.; Bayer, C. M.; Beckmann, M. W.; Wachter, D. L.; Uder, M.; Meier-Meitinger, M.; Brehm, B.

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography. PMID:25684789

  17. The accuracy of transvaginal sonography to detect endometriosis cyst

    NASA Astrophysics Data System (ADS)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  18. Assessment: transcranial Doppler ultrasonography: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology.

    PubMed

    Sloan, M A; Alexandrov, A V; Tegeler, C H; Spencer, M P; Caplan, L R; Feldmann, E; Wechsler, L R; Newell, D W; Gomez, C R; Babikian, V L; Lefkowitz, D; Goldman, R S; Armon, C; Hsu, C Y; Goodin, D S

    2004-05-11

    To review the use of transcranial Doppler ultrasonography (TCD) and transcranial color-coded sonography (TCCS) for diagnosis. The authors searched the literature for evidence of 1) if TCD provides useful information in specific clinical settings; 2) if using this information improves clinical decision making, as reflected by improved patient outcomes; and 3) if TCD is preferable to other diagnostic tests in these clinical situations. TCD is of established value in the screening of children aged 2 to 16 years with sickle cell disease for stroke risk (Type A, Class I) and the detection and monitoring of angiographic vasospasm after spontaneous subarachnoid hemorrhage (Type A, Class I to II). TCD and TCCS provide important information and may have value for detection of intracranial steno-occlusive disease (Type B, Class II to III), vasomotor reactivity testing (Type B, Class II to III), detection of cerebral circulatory arrest/brain death (Type A, Class II), monitoring carotid endarterectomy (Type B, Class II to III), monitoring cerebral thrombolysis (Type B, Class II to III), and monitoring coronary artery bypass graft operations (Type B to C, Class II to III). Contrast-enhanced TCD/TCCS can also provide useful information in right-to-left cardiac/extracardiac shunts (Type A, Class II), intracranial occlusive disease (Type B, Class II to IV), and hemorrhagic cerebrovascular disease (Type B, Class II to IV), although other techniques may be preferable in these settings.

  19. The implementation of thermal image visualization by HDL based on pseudo-color

    NASA Astrophysics Data System (ADS)

    Zhu, Yong; Zhang, JiangLing

    2004-11-01

    The pseudo-color method which maps the sampled data to intuitive perception colors is a kind of powerful visualization way. And the all-around system of pseudo-color visualization, which includes the primary principle, model and HDL (Hardware Description Language) implementation for the thermal images, is expatiated on in the paper. The thermal images whose signal is modulated as video reflect the temperature distribution of measured object, so they have the speciality of mass and real-time. The solution to the intractable problem is as follows: First, the reasonable system, i.e. the combining of global pseudo-color visualization and local special area accurate measure, muse be adopted. Then, the HDL pseudo-color algorithms in SoC (System on Chip) carry out the system to ensure the real-time. Finally, the key HDL algorithms for direct gray levels connection coding, proportional gray levels map coding and enhanced gray levels map coding are presented, and its simulation results are showed. The pseudo-color visualization of thermal images implemented by HDL in the paper has effective application in the aspect of electric power equipment test and medical health diagnosis.

  20. Mg2+ Effect on Argonaute and RNA Duplex by Molecular Dynamics and Bioinformatics Implications

    PubMed Central

    Nam, Seungyoon; Ryu, Hyojung; Son, Won-joon; Kim, Yon Hui; Kim, Kyung Tae; Balch, Curt; Nephew, Kenneth P.; Lee, Jinhyuk

    2014-01-01

    RNA interference (RNAi), mediated by small non-coding RNAs (e.g., miRNAs, siRNAs), influences diverse cellular functions. Highly complementary miRNA-target RNA (or siRNA-target RNA) duplexes are recognized by an Argonaute family protein (Ago2), and recent observations indicate that the concentration of Mg2+ ions influences miRNA targeting of specific mRNAs, thereby modulating miRNA-mRNA networks. In the present report, we studied the thermodynamic effects of differential [Mg2+] on slicing (RNA silencing cycle) through molecular dynamics simulation analysis, and its subsequent statistical analysis. Those analyses revealed different structural conformations of the RNA duplex in Ago2, depending on Mg2+ concentration. We also demonstrate that cation effects on Ago2 structural flexibility are critical to its catalytic/functional activity, with low [Mg2+] favoring greater Ago2 flexibility (e.g., greater entropy) and less miRNA/mRNA duplex stability, thus favoring slicing. The latter finding was supported by a negative correlation between expression of an Mg2+ influx channel, TRPM7, and one miRNA’s (miR-378) ability to downregulate its mRNA target, TMEM245. These results imply that thermodynamics could be applied to siRNA-based therapeutic strategies, using highly complementary binding targets, because Ago2 is also involved in RNAi slicing by exogenous siRNAs. However, the efficacy of a siRNA-based approach will differ, to some extent, based on the Mg2+ concentration even within the same disease type; therefore, different siRNA-based approaches might be considered for patient-to-patient needs. PMID:25330448

  1. Color identification testing device

    NASA Technical Reports Server (NTRS)

    Brawner, E. L.; Martin, R.; Pate, W.

    1970-01-01

    Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.

  2. Major Breeding Plumage Color Differences of Male Ruffs (Philomachus pugnax) Are Not Associated With Coding Sequence Variation in the MC1R Gene

    PubMed Central

    Küpper, Clemens; Burke, Terry; Lank, David B.

    2015-01-01

    Sequence variation in the melanocortin-1 receptor (MC1R) gene explains color morph variation in several species of birds and mammals. Ruffs (Philomachus pugnax) exhibit major dark/light color differences in melanin-based male breeding plumage which is closely associated with alternative reproductive behavior. A previous study identified a microsatellite marker (Ppu020) near the MC1R locus associated with the presence/absence of ornamental plumage. We investigated whether coding sequence variation in the MC1R gene explains major dark/light plumage color variation and/or the presence/absence of ornamental plumage in ruffs. Among 821bp of the MC1R coding region from 44 male ruffs we found 3 single nucleotide polymorphisms, representing 1 nonsynonymous and 2 synonymous amino acid substitutions. None were associated with major dark/light color differences or the presence/absence of ornamental plumage. At all amino acid sites known to be functionally important in other avian species with dark/light plumage color variation, ruffs were either monomorphic or the shared polymorphism did not coincide with color morph. Neither ornamental plumage color differences nor the presence/absence of ornamental plumage in ruffs are likely to be caused entirely by amino acid variation within the coding regions of the MC1R locus. Regulatory elements and structural variation at other loci may be involved in melanin expression and contribute to the extreme plumage polymorphism observed in this species. PMID:25534935

  3. Sonographic findings of ruptured epidermal inclusion cysts in superficial soft tissue: emphasis on shapes, pericystic changes, and pericystic vascularity.

    PubMed

    Jin, Wook; Ryu, Kyung Nam; Kim, Gou Young; Kim, Hyun Cheol; Lee, Jae Hoon; Park, Ji Seon

    2008-02-01

    The purpose of this study was to retrospectively evaluate the sonographic findings of ruptured epidermal inclusion cysts in superficial soft tissue, with an emphasis on shapes, pericystic changes, and pericystic vascularity. The cases of 61 patients with surgically confirmed epidermal inclusion cysts were reviewed, and 13 patients were found to have ruptured cysts. The Ethics Committees of our institutions did not require patient approval or informed patient consent for this retrospective study. We evaluated the shapes, sizes, locations, pericystic changes, and pericystic vascularity for the 13 cases. The shapes of the ruptured epidermal inclusion cysts were classified into 3 types: with lobulations (type I, 2 cases), with protrusions (type II, 8 cases), and with abscess pocket formations (type III, 3 cases). The mean long diameter of the cysts was 3 cm. Common sites of ruptured epidermal inclusion cysts were the plantar surface of the metatarsophalangeal joint (4 cases) and buttocks (3 cases). Pericystic changes were noted in all of the type II and III cysts. Increased vascularity on color Doppler sonography was prominent in 3 type II cysts and 3 type III cysts. Deep abscess formation was noted in the epidermal inclusion cysts, especially for the type III cysts. A ruptured epidermal inclusion cyst visualized by sonography had variable shapes; the sonographic findings can be useful for obtaining a correct diagnosis of a ruptured epidermal inclusion cyst.

  4. The photo-colorimetric space as a medium for the representation of spatial data

    NASA Technical Reports Server (NTRS)

    Kraiss, K. Friedrich; Widdel, Heino

    1989-01-01

    Spatial displays and instruments are usually used in the context of vehicle guidance, but it is hard to find applicable spatial formats in information retrieval and interaction systems. Human interaction with spatial data structures and the applicability of the CIE color space to improve dialogue transparency is discussed. A proposal is made to use the color space to code spatially represented data. The semantic distances of the categories of dialogue structures or, more general, of database structures, are determined empirically. Subsequently the distances are transformed and depicted into the color space. The concept is demonstrated for a car diagnosis system, where the category cooling system could, e.g., be coded in blue, the category ignition system in red. Hereby a correspondence between color and semantic distances is achieved. Subcategories can be coded as luminance differences within the color space.

  5. Cerebral blood flow modulations during cognitive control in major depressive disorder.

    PubMed

    Hoffmann, Alexandra; Montoro, Casandra I; Reyes Del Paso, Gustavo A; Duschek, Stefan

    2018-09-01

    This study investigated cerebral blood flow modulations during proactive and reactive cognitive control in major depressive disorder (MDD). Proactive control refers to preparatory processes during anticipation of a behaviorally relevant event; reactive control is activated after such an event to ensure goal attainment. Using functional transcranial Doppler sonography, blood flow velocities in the middle cerebral arteries of both hemispheres were recorded in 40 MDD patients and 40 healthy controls during a precued Stroop task. The font color of color words, which appeared 5 s after an acoustic warning signal, had to be indicated while ignoring word meaning. Patients, as compared to controls, exhibited smaller bilateral blood flow increases during task preparation and larger increases after color word presentation. Response time was longer in patients irrespective of the match or mismatch between font color and word meaning. The blood flow increase after word presentation correlated positively with response time. Potential effects of psychotropic medication on cognition and cerebral blood flow could not be controlled. The study revealed evidence of reduced cortical activity during proactive and elevated activity that occurs during reactive control in MDD. Deficient implementation of proactive control in MDD may lead to increased reliance on reactive control. The association between the blood flow increase after color word presentation and poorer performance indicates that deficient response preparation cannot be compensated for by reactive strategies. The findings are clinically relevant, as they may contribute to our understanding of the mechanisms relevant to cognitive impairments in MDD. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Bandwidth efficient bidirectional 5 Gb/s overlapped-SCM WDM PON with electronic equalization and forward-error correction.

    PubMed

    Buset, Jonathan M; El-Sahn, Ziad A; Plant, David V

    2012-06-18

    We demonstrate an improved overlapped-subcarrier multiplexed (O-SCM) WDM PON architecture transmitting over a single feeder using cost sensitive intensity modulation/direct detection transceivers, data re-modulation and simple electronics. Incorporating electronic equalization and Reed-Solomon forward-error correction codes helps to overcome the bandwidth limitation of a remotely seeded reflective semiconductor optical amplifier (RSOA)-based ONU transmitter. The O-SCM architecture yields greater spectral efficiency and higher bit rates than many other SCM techniques while maintaining resilience to upstream impairments. We demonstrate full-duplex 5 Gb/s transmission over 20 km and analyze BER performance as a function of transmitted and received power. The architecture provides flexibility to network operators by relaxing common design constraints and enabling full-duplex operation at BER ∼ 10(-10) over a wide range of OLT launch powers from 3.5 to 8 dBm.

  7. Landing Hazard Avoidance Display

    NASA Technical Reports Server (NTRS)

    Abernathy, Michael Franklin (Inventor); Hirsh, Robert L. (Inventor)

    2016-01-01

    Landing hazard avoidance displays can provide rapidly understood visual indications of where it is safe to land a vehicle and where it is unsafe to land a vehicle. Color coded maps can indicate zones in two dimensions relative to the vehicles position where it is safe to land. The map can be simply green (safe) and red (unsafe) areas with an indication of scale or can be a color coding of another map such as a surface map. The color coding can be determined in real time based on topological measurements and safety criteria to thereby adapt to dynamic, unknown, or partially known environments.

  8. Compress compound images in H.264/MPGE-4 AVC by exploiting spatial correlation.

    PubMed

    Lan, Cuiling; Shi, Guangming; Wu, Feng

    2010-04-01

    Compound images are a combination of text, graphics and natural image. They present strong anisotropic features, especially on the text and graphics parts. These anisotropic features often render conventional compression inefficient. Thus, this paper proposes a novel coding scheme from the H.264 intraframe coding. In the scheme, two new intramodes are developed to better exploit spatial correlation in compound images. The first is the residual scalar quantization (RSQ) mode, where intrapredicted residues are directly quantized and coded without transform. The second is the base colors and index map (BCIM) mode that can be viewed as an adaptive color quantization. In this mode, an image block is represented by several representative colors, referred to as base colors, and an index map to compress. Every block selects its coding mode from two new modes and the previous intramodes in H.264 by rate-distortion optimization (RDO). Experimental results show that the proposed scheme improves the coding efficiency even more than 10 dB at most bit rates for compound images and keeps a comparable efficient performance to H.264 for natural images.

  9. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    PubMed

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland-Altman plot, there were no statistical significant difference (P<0.05). Images from the sonography could provide visualization of the fracture during reduction and MIPO as accurately as the radiography. Thus, the sonography assisted MIPO in femoral shaft fracture can be done effectively comparing with radiographic assisted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Theoretical research on color indirect effects

    NASA Astrophysics Data System (ADS)

    Liu, T. C.; Liao, Changjun; Liu, Songhao

    1995-05-01

    Color indirect effects (CIE) means the physiological and psychological effects of color resulting from color vision. In this paper, we study CIE from the viewpoints of the integrated western and Chinese traditional medicine and the time quantum theory established by C. Y. Liu et al., respectively, and then put forward the color-automatic-nervous-subsystem model that could color excites parasympathetic subsystem and hot color excites sympathetic subsystem. Our theory is in agreement with modern color vision theory, and moreover, it leads to the resolution of the conflict between the color code theory and the time code theory oncolor vision. For the latitude phenomena on athlete stars number and the average lifespan, we also discuss the possibility of UV vision. The applications of our theory lead to our succeeding in explaining a number of physiological and psychological effects of color, in explaining the effects of age on color vision, and in explaining the Chinese chromophototherapy. We also discuss its application to neuroimmunology. This research provides the foundation of the clinical applications of chromophototherapy.

  11. Development of a duplex real-time RT-qPCR assay to monitor genome replication, gene expression and gene insert stability during in vivo replication of a prototype live attenuated canine distemper virus vector encoding SIV gag.

    PubMed

    Coleman, John W; Wright, Kevin J; Wallace, Olivia L; Sharma, Palka; Arendt, Heather; Martinez, Jennifer; DeStefano, Joanne; Zamb, Timothy P; Zhang, Xinsheng; Parks, Christopher L

    2015-03-01

    Advancement of new vaccines based on live viral vectors requires sensitive assays to analyze in vivo replication, gene expression and genetic stability. In this study, attenuated canine distemper virus (CDV) was used as a vaccine delivery vector and duplex 2-step quantitative real-time RT-PCR (RT-qPCR) assays specific for genomic RNA (gRNA) or mRNA have been developed that concurrently quantify coding sequences for the CDV nucleocapsid protein (N) and a foreign vaccine antigen (SIV Gag). These amplicons, which had detection limits of about 10 copies per PCR reaction, were used to show that abdominal cavity lymphoid tissues were a primary site of CDV vector replication in infected ferrets, and importantly, CDV gRNA or mRNA was undetectable in brain tissue. In addition, the gRNA duplex assay was adapted for monitoring foreign gene insert genetic stability during in vivo replication by analyzing the ratio of CDV N and SIV gag genomic RNA copies over the course of vector infection. This measurement was found to be a sensitive probe for assessing the in vivo genetic stability of the foreign gene insert. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Nucleic Acid Chaperone Activity of the ORF1 Protein from the Mouse LINE-1 Retrotransposon

    PubMed Central

    Martin, Sandra L.; Bushman, Frederic D.

    2001-01-01

    Non-LTR retrotransposons such as L1 elements are major components of the mammalian genome, but their mechanism of replication is incompletely understood. Like retroviruses and LTR-containing retrotransposons, non-LTR retrotransposons replicate by reverse transcription of an RNA intermediate. The details of cDNA priming and integration, however, differ between these two classes. In retroviruses, the nucleocapsid (NC) protein has been shown to assist reverse transcription by acting as a “nucleic acid chaperone,” promoting the formation of the most stable duplexes between nucleic acid molecules. A protein-coding region with an NC-like sequence is present in most non-LTR retrotransposons, but no such sequence is evident in mammalian L1 elements or other members of its class. Here we investigated the ORF1 protein from mouse L1 and found that it does in fact display nucleic acid chaperone activities in vitro. L1 ORF1p (i) promoted annealing of complementary DNA strands, (ii) facilitated strand exchange to form the most stable hybrids in competitive displacement assays, and (iii) facilitated melting of an imperfect duplex but stabilized perfect duplexes. These findings suggest a role for L1 ORF1p in mediating nucleic acid strand transfer steps during L1 reverse transcription. PMID:11134335

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayashi, A.; Hashimoto, T.; Horibe, M.

    The quantum color coding scheme proposed by Korff and Kempe [e-print quant-ph/0405086] is easily extended so that the color coding quantum system is allowed to be entangled with an extra auxiliary quantum system. It is shown that in the extended scheme we need only {approx}2{radical}(N) quantum colors to order N objects in large N limit, whereas {approx}N/e quantum colors are required in the original nonextended version. The maximum success probability has asymptotics expressed by the Tracy-Widom distribution of the largest eigenvalue of a random Gaussian unitary ensemble (GUE) matrix.

  14. Contrast-enhanced sonography in pediatrics.

    PubMed

    McCarville, M Beth

    2011-05-01

    Microbubble US contrast agents are composed of an outer shell of protein, phospholipid or polymer that encase air or perfluorocarbon gas. These contrast agents have been widely used in adult cardiology patients to improve endocardial border delineation and have been proved safe and well tolerated in this patient population. There is also a growing body of literature elucidating the value of contrast-enhanced sonography to distinguish benign from malignant liver lesions in adults and to characterize non-hepatic adult malignancies. Because these agents have not been approved for pediatric use in many countries, less is known of the value of contrast-enhanced sonography in children. In this review I will discuss several proven and potential pediatric applications of contrast-enhanced sonography.

  15. Sonography in the postoperative evaluation of laparoscopic inguinal hernia repair.

    PubMed

    Furtschegger, A; Sandbichler, P; Judmaier, W; Gstir, H; Steiner, E; Egender, G

    1995-09-01

    We evaluated the use of sonography as a means of assessing hernial occlusion and possible postoperative changes such as hematomas or seromas in the inguinal and scrotal regions after 1139 laparoscopic repairs of hernias between August 1992 and November 1994. Changes after laparoscopic hernia repair were found in 307 patients (27%). Hematomas or seromas were seen in 132 patients, protrusion of the prosthetic mesh in 17, mesh infection in two, and small bowel entrapment in an insufficient peritoneal suture in two. Recurrences were diagnosed correctly in six patients, mobile preperitoneal lipomas in five. Sonography is useful in the evaluation of complications after laparoscopic hernia repair, including recurrent hernia. In the absence of symptoms, sonography is not indicated.

  16. Extended Colour--Some Methods and Applications.

    ERIC Educational Resources Information Center

    Dean, P. J.; Murkett, A. J.

    1985-01-01

    Describes how color graphics are built up on microcomputer displays and how a range of colors can be produced. Discusses the logic of color formation, noting that adding/subtracting color can be conveniently demonstrated. Color generating techniques in physics (resistor color coding and continuous spectrum production) are given with program…

  17. Doppler sonography characteristics of vertebrobasilar circulation in patients with Parkinson's disease.

    PubMed

    Vidović, Mirjana; Sinanović, Osman; Smajlović, Dzevdet; Burina, Adnan; Hudić, Josip

    2008-08-01

    The objective of the study was to analyze the doppler sonography findings of vertebrobasilar circulation (VB) in patients with Parkinson's disease. 40 patients were analyzed (25 men's and 15 women) with Parkinson's disease, average age was 61.9 years (SD=11.43), treated at the Clinic for Neurology in Tuzla. Device for doppler sonography was Multidop x 4. Doppler sonography findings of VB circulation were analyzed in order to computerized tomography (CT) findings of the brain (with or without ischemic lacunar lesions) and in order to presence of postural disturbances as one of dominant Parkinson's disease symptoms during actual hospitalization. Our results suggest that vertebrobasilar insufficiency is more frequent in patients with Parkinson's disease (no matter of type) and postural disturbances as a dominant symptom comparing to group of Parkinson's disease patients without postural disturbances. These results implicate the importance of doppler sonography findings of vertebrobasilar circulation in patients with Parkinson's disease and possibility of considering role of vertebrobasilar insufficiency in development of postural disturbances.

  18. Assessment of Optical Coherence Tomography Color Probability Codes in Myopic Glaucoma Eyes After Applying a Myopic Normative Database.

    PubMed

    Seol, Bo Ram; Kim, Dong Myung; Park, Ki Ho; Jeoung, Jin Wook

    2017-11-01

    To evaluate the optical coherence tomography (OCT) color probability codes based on a myopic normative database and to investigate whether the implementation of the myopic normative database can improve the OCT diagnostic ability in myopic glaucoma. Comparative validity study. In this study, 305 eyes (154 myopic healthy eyes and 151 myopic glaucoma eyes) were included. A myopic normative database was obtained based on myopic healthy eyes. We evaluated the agreement between OCT color probability codes after applying the built-in and myopic normative databases, respectively. Another 120 eyes (60 myopic healthy eyes and 60 myopic glaucoma eyes) were included and the diagnostic performance of OCT color codes using a myopic normative database was investigated. The mean weighted kappa (Kw) coefficients for quadrant retinal nerve fiber layer (RNFL) thickness, clock-hour RNFL thickness, and ganglion cell-inner plexiform layer (GCIPL) thickness were 0.636, 0.627, and 0.564, respectively. The myopic normative database showed a higher specificity than did the built-in normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P < .001, P < .001, and P < .001, respectively). The receiver operating characteristic curve values increased when using the myopic normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P = .011, P = .004, P < .001, respectively). The diagnostic ability of OCT color codes for detection of myopic glaucoma significantly improved after application of the myopic normative database. The implementation of a myopic normative database is needed to allow more precise interpretation of OCT color probability codes when used in myopic eyes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Color-Coded Prefilled Medication Syringes Decrease Time to Delivery and Dosing Error in Simulated Emergency Department Pediatric Resuscitations.

    PubMed

    Moreira, Maria E; Hernandez, Caleb; Stevens, Allen D; Jones, Seth; Sande, Margaret; Blumen, Jason R; Hopkins, Emily; Bakes, Katherine; Haukoos, Jason S

    2015-08-01

    The Institute of Medicine has called on the US health care system to identify and reduce medical errors. Unfortunately, medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients when dosing requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national health care priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared with conventional medication administration, in simulated pediatric emergency department (ED) resuscitation scenarios. We performed a prospective, block-randomized, crossover study in which 10 emergency physician and nurse teams managed 2 simulated pediatric arrest scenarios in situ, using either prefilled, color-coded syringes (intervention) or conventional drug administration methods (control). The ED resuscitation room and the intravenous medication port were video recorded during the simulations. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the conventional and color-coded delivery groups was 47 seconds (95% confidence interval [CI] 40 to 53 seconds) and 19 seconds (95% CI 18 to 20 seconds), respectively (difference=27 seconds; 95% CI 21 to 33 seconds). With the conventional method, 118 doses were administered, with 20 critical dosing errors (17%); with the color-coded method, 123 doses were administered, with 0 critical dosing errors (difference=17%; 95% CI 4% to 30%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by emergency physician and nurse teams during simulated pediatric ED resuscitations. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  20. Modeling of rolling element bearing mechanics. Computer program user's manual

    NASA Technical Reports Server (NTRS)

    Greenhill, Lyn M.; Merchant, David H.

    1994-01-01

    This report provides the user's manual for the Rolling Element Bearing Analysis System (REBANS) analysis code which determines the quasistatic response to external loads or displacement of three types of high-speed rolling element bearings: angular contact ball bearings, duplex angular contact ball bearings, and cylindrical roller bearings. The model includes the defects of bearing ring and support structure flexibility. It is comprised of two main programs: the Preprocessor for Bearing Analysis (PREBAN) which creates the input files for the main analysis program, and Flexibility Enhanced Rolling Element Bearing Analysis (FEREBA), the main analysis program. This report addresses input instructions for and features of the computer codes. A companion report addresses the theoretical basis for the computer codes. REBANS extends the capabilities of the SHABERTH (Shaft and Bearing Thermal Analysis) code to include race and housing flexibility, including such effects as dead band and preload springs.

  1. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    PubMed

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  2. Using modern teaching strategies to teach upper abdominal sonography to medical students.

    PubMed

    Cheng, Wei-Chun; Lin, Xi-Zhang; Chen, Chiung-Yu

    2013-07-01

    Upper abdominal sonography can help physicians to confirm the diagnosis of various hepatobiliary diseases. Teaching sonography skills to medical students is important because it may enhance their level of knowledge and overall development during their gastroenterology section rotation. Sonographic imaging is abstract and students can be easily confused when scanning the abdominal structures from different sites and directions. We used several modern teaching strategies to facilitate the learning of sonography skills. The year five medical students beginning a gastroenterology section rotation for their first-year clerkship were taught abdominal sonography skills. Abstract sonographic images were related to concrete objects and the surrounding structures were further indicated. Each of the images was given a specific name and was sorted according to the scanning site. A mnemonics system was designed to help students to memorize the names of these images. A badge was created to recognize the achievement of being able to complete a basic upper abdominal sonography. Students were free (i.e., not obligated) to request a demonstration opportunity to show their skills within 2 weeks after receiving tutelage. We recorded the number of students who received training and were able to successfully complete the task; these individuals then received a badge to be pinned onto their white coats. Sixty-three of 68 students (92.6%) requested evaluation and all of them passed. We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives. Copyright © 2013. Published by Elsevier B.V.

  3. Reliability and precision of stress sonography of the ulnar collateral ligament.

    PubMed

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  4. Short-range forecast of Shershnevskoie (South Ural) water-storage algal blooms: preliminary results of predictors' choosing and membership functions' construction

    NASA Astrophysics Data System (ADS)

    Gayazova, Anna; Abdullaev, Sanjar

    2014-05-01

    Short-range forecasting of algal blooms in drinking water reservoirs and other waterbodies is an actual element of water treatment system. Particularly, Shershnevskoie reservoir - the source of drinking water for Chelyabinsk city (South Ural region of Russia) - is exposed to interannual, seasonal and short-range fluctuations of blue-green alga Aphanizomenon flos-aquae and other dominant species abundance, which lead to technological problems and economic costs and adversely affect the water treatment quality. Whereas the composition, intensity and the period of blooms affected not only by meteorological seasonal conditions but also by ecological specificity of waterbody, that's important to develop object-oriented forecasting, particularly, search for an optimal number of predictors for such forecasting. Thereby, firstly fuzzy logic and fuzzy artificial neural network patterns for blue-green alga Microcystis aeruginosa (M. aeruginosa) blooms prediction in nearby undrained Smolino lake were developed. These results subsequently served as the base to derive membership functions for Shernevskoie reservoir forecasting patterns. Time series with the total lenght about 138-159 days of dominant species seasonal abundance, water temperature, cloud cover, wind speed, mineralization, phosphate and nitrate concentrations were obtained through field observations held at Lake Smolino (Chelyabinsk) in the warm season of 2009 and 2011 with time resolution of 2-7 days. The cross-correlation analysis of the data revealed the potential predictors of M. aeruginosa abundance quasi-periodic oscillations: green alga Pediastrum duplex (P. duplex) abundance and mineralization for 2009, P. duplex abundance, water temperature and concentration of nitrates for 2011. According to the results of cross-correlation analysis one membership function "P. duplex abundance" and one rule linking M. aeruginosa and P. duplex abundances were set up for database of 2009. Analogically, for database of 2011 three rules, linking membership functions of temperature, P. duplex abundance, nitrate concentration and M. aeruginosa abundance were set up. Developed fuzzy logic rules were good to predict M. aeruginosa intense outbreaks. For ANN method of forecasting specially written program was used to train the fuzzy artificial neural network on number of input selected predictors' values and output predicted factor's values to set up the predictive rules and membership functions automatically. As a result, two models based on mineralization and P. duplex abundance were developed for 2009. For 2011 four patterns were developed, the best result was obtained for model based on temperature and P. duplex abundance. Developed methods of forecasting were applied to predict outbreaks of Aphanizomenon flos-aquae and M. aeruginosa abundance in Shershnevskoie reservoir. For this purpose long-term data of chemical parameters, measured once in a month, data of dominant species abundance, measured fifth in a week and data of turbidity, water color, alkalinity, pH, obtained each day, were analyzed. Based on these empirical data significant factors were determined, membership functions were set up and preliminary models for Shershnevskoie reservoir were developed. As expected, these models differ significantly from developed for Smolino lake ones and should be tested on new data sets.

  5. The effect of a redundant color code on an overlearned identification task

    NASA Technical Reports Server (NTRS)

    Obrien, Kevin

    1992-01-01

    The possibility of finding redundancy gains with overlearned tasks was examined using a paradigm varying familiarity with the stimulus set. Redundant coding in a multidimensional stimulus was demonstrated to result in increased identification accuracy and decreased latency of identification when compared to stimuli varying on only one dimension. The advantages attributable to redundant coding are referred to as redundancy gain and were found for a variety of stimulus dimension combinations, including the use of hue or color as one of the dimensions. Factors that have affected redundancy gain include the discriminability of the levels of one stimulus dimension and the level of stimulus-to-response association. The results demonstrated that response time is in part a function of familiarity, but no effect of redundant color coding was demonstrated. Implications of research on coding in identification tasks for display design are discussed.

  6. Three-dimensional quick response code based on inkjet printing of upconversion fluorescent nanoparticles for drug anti-counterfeiting

    NASA Astrophysics Data System (ADS)

    You, Minli; Lin, Min; Wang, Shurui; Wang, Xuemin; Zhang, Ge; Hong, Yuan; Dong, Yuqing; Jin, Guorui; Xu, Feng

    2016-05-01

    Medicine counterfeiting is a serious issue worldwide, involving potentially devastating health repercussions. Advanced anti-counterfeit technology for drugs has therefore aroused intensive interest. However, existing anti-counterfeit technologies are associated with drawbacks such as the high cost, complex fabrication process, sophisticated operation and incapability in authenticating drug ingredients. In this contribution, we developed a smart phone recognition based upconversion fluorescent three-dimensional (3D) quick response (QR) code for tracking and anti-counterfeiting of drugs. We firstly formulated three colored inks incorporating upconversion nanoparticles with RGB (i.e., red, green and blue) emission colors. Using a modified inkjet printer, we printed a series of colors by precisely regulating the overlap of these three inks. Meanwhile, we developed a multilayer printing and splitting technology, which significantly increases the information storage capacity per unit area. As an example, we directly printed the upconversion fluorescent 3D QR code on the surface of drug capsules. The 3D QR code consisted of three different color layers with each layer encoded by information of different aspects of the drug. A smart phone APP was designed to decode the multicolor 3D QR code, providing the authenticity and related information of drugs. The developed technology possesses merits in terms of low cost, ease of operation, high throughput and high information capacity, thus holds great potential for drug anti-counterfeiting.Medicine counterfeiting is a serious issue worldwide, involving potentially devastating health repercussions. Advanced anti-counterfeit technology for drugs has therefore aroused intensive interest. However, existing anti-counterfeit technologies are associated with drawbacks such as the high cost, complex fabrication process, sophisticated operation and incapability in authenticating drug ingredients. In this contribution, we developed a smart phone recognition based upconversion fluorescent three-dimensional (3D) quick response (QR) code for tracking and anti-counterfeiting of drugs. We firstly formulated three colored inks incorporating upconversion nanoparticles with RGB (i.e., red, green and blue) emission colors. Using a modified inkjet printer, we printed a series of colors by precisely regulating the overlap of these three inks. Meanwhile, we developed a multilayer printing and splitting technology, which significantly increases the information storage capacity per unit area. As an example, we directly printed the upconversion fluorescent 3D QR code on the surface of drug capsules. The 3D QR code consisted of three different color layers with each layer encoded by information of different aspects of the drug. A smart phone APP was designed to decode the multicolor 3D QR code, providing the authenticity and related information of drugs. The developed technology possesses merits in terms of low cost, ease of operation, high throughput and high information capacity, thus holds great potential for drug anti-counterfeiting. Electronic supplementary information (ESI) available: Calculating details of UCNP content per 3D QR code and decoding process of the 3D QR code. See DOI: 10.1039/c6nr01353h

  7. Effects of Gender Color-Coding on Toddlers' Gender-Typical Toy Play.

    PubMed

    Wong, Wang I; Hines, Melissa

    2015-07-01

    Gender color-coding of children's toys may make certain toys more appealing or less appealing to a given gender. We observed toddlers playing with two gender-typical toys (a train, a doll), once in gender-typical colors and once in gender-atypical colors. Assessments occurred twice, at 20-40 months of age and at 26-47 months of age. A Sex × Time × Toy × Color ANOVA showed expected interactions between Sex and Toy and Sex and Color. Boys played more with the train than girls did and girls played more with the doll and with pink toys than boys did. The Sex × Toy × Color interaction was not significant, but, at both time points, boys and girls combined played more with the gender-atypical toy when its color was typical for their sex than when it was not. This effect appeared to be caused largely by boys' preference for, or avoidance of, the doll and by the use of pink. Also, at both time points, gender differences in toy preferences were larger in the gender-typical than in the gender-atypical color condition. At Time 2, these gender differences were present only in the gender-typical color condition. Overall, the results suggest that, once acquired, gender-typical color preferences begin to influence toy preferences, especially those for gender-atypical toys and particularly in boys. They thus could enlarge differences between boys' and girls' toy preferences. Because boys' and girls' toys elicit different activities, removing the gender color-coding of toys could encourage more equal learning opportunities.

  8. Combining Topological Hardware and Topological Software: Color-Code Quantum Computing with Topological Superconductor Networks

    NASA Astrophysics Data System (ADS)

    Litinski, Daniel; Kesselring, Markus S.; Eisert, Jens; von Oppen, Felix

    2017-07-01

    We present a scalable architecture for fault-tolerant topological quantum computation using networks of voltage-controlled Majorana Cooper pair boxes and topological color codes for error correction. Color codes have a set of transversal gates which coincides with the set of topologically protected gates in Majorana-based systems, namely, the Clifford gates. In this way, we establish color codes as providing a natural setting in which advantages offered by topological hardware can be combined with those arising from topological error-correcting software for full-fledged fault-tolerant quantum computing. We provide a complete description of our architecture, including the underlying physical ingredients. We start by showing that in topological superconductor networks, hexagonal cells can be employed to serve as physical qubits for universal quantum computation, and we present protocols for realizing topologically protected Clifford gates. These hexagonal-cell qubits allow for a direct implementation of open-boundary color codes with ancilla-free syndrome read-out and logical T gates via magic-state distillation. For concreteness, we describe how the necessary operations can be implemented using networks of Majorana Cooper pair boxes, and we give a feasibility estimate for error correction in this architecture. Our approach is motivated by nanowire-based networks of topological superconductors, but it could also be realized in alternative settings such as quantum-Hall-superconductor hybrids.

  9. Bodybuilding-induced Mondor's disease of the chest wall.

    PubMed

    Tröbinger, Christian; Wiedermann, Christian J

    2017-01-01

    To describe the association of bodybuilding abdominal exercise with the development of superficial sclerosing thrombophlebitis of the anterolateral thoracoabdominal wall. A single case study. University-affiliated regional community hospital. A 54-year-old man presented with an otherwise unremarkable past medical history 4 weeks after the start of left-sided chest discomfort. He had undergone orthopedic surgery of the right shoulder three months earlier. Two months after surgery, he had re-started bodybuilding with thoracoabdominal training. Soon thereafter, he noted a painful induration at the left side of his trunk. Doppler and duplex sonography revealed complete venous occlusion compatible with sclerosing thrombophlebitis leading to a palpable, subcutaneous, cord-like lesion on the left side of his trunk. Physical examination and routine laboratory findings were normal. The lesion spontaneously resolved over a course of 3 months. Mondor's disease of the subcutaneous veins of the chest wall which has been associated with breast or axillary surgery, malignant and systemic diseases can also appear in subjects performing intense thoracoabdominal exercise training. Although it requires only symptomatic therapy, physicians and therapists must be aware of the existence of this disease because, although benign and self-limiting, malignant and systemic diseases need to be ruled out. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Pseudo-color coding method for high-dynamic single-polarization SAR images

    NASA Astrophysics Data System (ADS)

    Feng, Zicheng; Liu, Xiaolin; Pei, Bingzhi

    2018-04-01

    A raw synthetic aperture radar (SAR) image usually has a 16-bit or higher bit depth, which cannot be directly visualized on 8-bit displays. In this study, we propose a pseudo-color coding method for high-dynamic singlepolarization SAR images. The method considers the characteristics of both SAR images and human perception. In HSI (hue, saturation and intensity) color space, the method carries out high-dynamic range tone mapping and pseudo-color processing simultaneously in order to avoid loss of details and to improve object identifiability. It is a highly efficient global algorithm.

  11. Keep It Simple. Teaching Tips for Special Olympic Athletes.

    ERIC Educational Resources Information Center

    Johnston, Judith E.; And Others

    1996-01-01

    Physical educators can help Special Olympics athletes learn cross-lateral delivery techniques for bowling or throwing softballs by color coding the throwing arm and opposing foot. The article explains color coding, presenting teaching tips for both sports. A series of workshops on modifying exercise principles for individuals with physical…

  12. Use of color-coded sleeve shutters accelerates oscillograph channel selection

    NASA Technical Reports Server (NTRS)

    Bouchlas, T.; Bowden, F. W.

    1967-01-01

    Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

  13. Color Coding of Circuit Quantities in Introductory Circuit Analysis Instruction

    ERIC Educational Resources Information Center

    Reisslein, Jana; Johnson, Amy M.; Reisslein, Martin

    2015-01-01

    Learning the analysis of electrical circuits represented by circuit diagrams is often challenging for novice students. An open research question in electrical circuit analysis instruction is whether color coding of the mathematical symbols (variables) that denote electrical quantities can improve circuit analysis learning. The present study…

  14. Acute testicular torsion in children: the role of sonography in the diagnostic workup.

    PubMed

    Gunther, P; Schenk, J P; Wunsch, R; Holland-Cunz, S; Kessler, U; Troger, J; Waag, K L

    2006-11-01

    Acute testicular torsion in children is an emergency and has to be diagnosed urgently. Doppler sonography is increasingly used in imaging the acute scrotum. Nevertheless, in uncertain cases, surgical exploration is required. In this study, we attempted to define the role of Doppler sonography in the diagnostic workup of the acutely painful scrotum. All patients admitted between 1999 and 2005 with acute scrotal pain were included. After clinical assessment, patients were imaged by Doppler sonography with a ''high-end'' instrument. In cases of absent arterial perfusion of the testis in Doppler sonography, surgical exploration was carried out. Patients with unaffected perfusion were followed clinically by ultrasound for up to 2 years. Sixty-one infants and children aged 1 day to 17 years (median: 7.9 years) were included. In 14 cases, sonography demonstrated absent central perfusion, with abnormal parenchymal echogenicity in six. Absence of venous blood flow together with reduction of central arterial perfusion was found in one infant. In these 15 patients, surgical exploration confirmed testicular torsion. Among the other 46 patients, we found four cases with increased testicular perfusion and 27 with increased perfusion of the epididymis. In one infant, a testicular tumour was found sonographically, and orchiectomy confirmed diagnosis of a teratoma. Follow-up examinations of the conservatively treated patients showed good clinical outcome with physiologic central perfusion as well as normal echogenic pattern of both testes. No case of testicular torsion was missed. By means of Doppler sonography, an unequivocal statement regarding testicular perfusion was possible in all cases. The initial Doppler diagnosis was confirmed by operative evaluation and follow-up ultrasound. Testicular torsion can therefore be excluded by correctly performed ultrasound with modern equipment.

  15. Three-step sequential positioning algorithm during sonographic evaluation for appendicitis increases appendiceal visualization rate and reduces CT use.

    PubMed

    Chang, Stephanie T; Jeffrey, R Brooke; Olcott, Eric W

    2014-11-01

    The purpose of this article is to examine the rates of appendiceal visualization by sonography, imaging-based diagnoses of appendicitis, and CT use after appendiceal sonography, before and after the introduction of a sonographic algorithm involving sequential changes in patient positioning. We used a search engine to retrospectively identify patients who underwent graded-compression sonography for suspected appendicitis during 6-month periods before (period 1; 419 patients) and after (period 2; 486 patients) implementation of a new three-step positional sonographic algorithm. The new algorithm included initial conventional supine scanning and, as long as the appendix remained nonvisualized, left posterior oblique scanning and then "second-look" supine scanning. Abdominal CT within 7 days after sonography was recorded. Between periods 1 and 2, appendiceal visualization on sonography increased from 31.0% to 52.5% (p < 0.001), postsonography CT use decreased from 31.3% to 17.7% (p < 0.001), and the proportion of imaging-based diagnoses of appendicitis made by sonography increased from 63.8% to 85.7% (p = 0.002). The incidence of appendicitis diagnosed by imaging (either sonography or CT) remained similar at 16.5% and 17.3%, respectively (p = 0.790). Sensitivity and overall accuracy were 57.8% (95% CI, 44.8-70.1%) and 93.0% (95% CI, 90.1-95.3%), respectively, in period 1 and 76.5% (95% CI, 65.8-85.2%) and 95.4% (95% CI, 93.1-97.1%), respectively, in period 2. Similar findings were observed for adults and children. Implementation of an ultrasound algorithm with sequential positioning significantly improved the appendiceal visualization rate and the proportion of imaging-based diagnoses of appendicitis made by ultrasound, enabling a concomitant decrease in abdominal CT use in both children and adults.

  16. Comparison the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination or ultrasound methods.

    PubMed

    Karimzadeh, Hadi; Seyedbonakdar, Zahra; Mousavi, Maryam; Karami, Mehdi

    2016-01-01

    This study aimed to compare the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination and ultrasound methods. This study is a cross-sectional study which was conducted in Al-Zahra Hospital (Isfahan, Iran) during 2014-2015. In our study, ninety patients were selected based on the American College of Rheumatology 2010 criteria. All patients were examined by a rheumatologist to find the existence of effusion, and the data were filled in the checklist. The ultrasonography for detecting effusion in periarticular structures was done by an expert radiologist with two methods, including high-resolution ultrasonography and power Doppler. The percentage of effusion existence found by physical examination was compared by sonography, and the Chi-square and t -tests were used for data analysis. The percentage of effusion found in areas with physical examination by rheumatologist was lower than the frequency distribution of effusions found by sonography (8.3% VS 14.2%) ( P < 0.001). In sonography, rotator cuff tendonitis is the most common periarthritis. Other findings in sonography were biceps tendinitis (10 cases), wrist tendonitis (13 cases), olecranon bursitis (9 cases), golfers elbow (4 cases), tennis elbow (4 cases), trochanteric bursitis (6 cases), anserine bursitis (6 cases), prepatellar bursitis (11 cases), and ankle tendonitis (7 cases). Tenderness on physical examination was found in 15% of the cases, and the evidence of periarthritis was found in 21/7% through sonography ( P < 0.001) and 34% through Doppler sonography ( P < 0.001). The percentage of periarthritis detection by ultrasonography and power Doppler sonography was higher than clinical examination. Hence, the ultrasonography is more accurate than physical examination.

  17. Comparison the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination or ultrasound methods

    PubMed Central

    Karimzadeh, Hadi; Seyedbonakdar, Zahra; Mousavi, Maryam; Karami, Mehdi

    2016-01-01

    Background: This study aimed to compare the percentage of detection of periarthritis in patients with rheumatoid arthritis using clinical examination and ultrasound methods. Materials and Methods: This study is a cross-sectional study which was conducted in Al-Zahra Hospital (Isfahan, Iran) during 2014–2015. In our study, ninety patients were selected based on the American College of Rheumatology 2010 criteria. All patients were examined by a rheumatologist to find the existence of effusion, and the data were filled in the checklist. The ultrasonography for detecting effusion in periarticular structures was done by an expert radiologist with two methods, including high-resolution ultrasonography and power Doppler. The percentage of effusion existence found by physical examination was compared by sonography, and the Chi-square and t-tests were used for data analysis. Results: The percentage of effusion found in areas with physical examination by rheumatologist was lower than the frequency distribution of effusions found by sonography (8.3% VS 14.2%) (P < 0.001). In sonography, rotator cuff tendonitis is the most common periarthritis. Other findings in sonography were biceps tendinitis (10 cases), wrist tendonitis (13 cases), olecranon bursitis (9 cases), golfers elbow (4 cases), tennis elbow (4 cases), trochanteric bursitis (6 cases), anserine bursitis (6 cases), prepatellar bursitis (11 cases), and ankle tendonitis (7 cases). Tenderness on physical examination was found in 15% of the cases, and the evidence of periarthritis was found in 21/7% through sonography (P < 0.001) and 34% through Doppler sonography (P < 0.001). Conclusion: The percentage of periarthritis detection by ultrasonography and power Doppler sonography was higher than clinical examination. Hence, the ultrasonography is more accurate than physical examination. PMID:28331520

  18. Error threshold for color codes and random three-body Ising models.

    PubMed

    Katzgraber, Helmut G; Bombin, H; Martin-Delgado, M A

    2009-08-28

    We study the error threshold of color codes, a class of topological quantum codes that allow a direct implementation of quantum Clifford gates suitable for entanglement distillation, teleportation, and fault-tolerant quantum computation. We map the error-correction process onto a statistical mechanical random three-body Ising model and study its phase diagram via Monte Carlo simulations. The obtained error threshold of p(c) = 0.109(2) is very close to that of Kitaev's toric code, showing that enhanced computational capabilities do not necessarily imply lower resistance to noise.

  19. Locoregional spread of cutaneous melanoma: sonography findings.

    PubMed

    Catalano, Orlando; Caracò, Corrado; Mozzillo, Nicola; Siani, Alfredo

    2010-03-01

    This article reviews various aspects of locoregional spread of malignant cutaneous melanoma, as imaged with gray-scale sonography and Doppler techniques. The scenarios illustrated include disease staging (primary melanoma, satellite metastasis, in-transit metastasis, and lymphadenopathies), sentinel lymph node biopsy procedure, patient follow-up, recurrence detection, cutaneous metastasis, and sonographically guided intervention. High-resolution sonography allows recognition of small, clinically-occult melanomatous foci. It plays a major role in locoregional staging and follow-up of patients with cutaneous melanoma.

  20. Internal gravity, self-energy, and disruption of comets and asteroids

    NASA Astrophysics Data System (ADS)

    Dobrovolskis, Anthony R.; Korycansky, D. G.

    2018-03-01

    The internal gravity and self-gravitational energy of a comet, asteroid, or small moon have applications to their geophysics, including their formation, evolution, cratering, and disruption, the stresses and strains inside such objects, sample return, eventual asteroid mining, and planetary defense strategies for potentially hazardous objects. This paper describes the relation of an object's self-energy to its collisional disruption energy, and shows how to determine an object's self-energy from its internal gravitational potential. Any solid object can be approximated to any desired accuracy by a polyhedron of sufficient complexity. An analytic formula is known for the gravitational potential of any homogeneous polyhedron, but it is widely believed that this formula applies only on the surface or outside of the object. Here we show instead that this formula applies equally well inside the object. We have used these formulae to develop a numerical code which evaluates the self-energy of any homogeneous polyhedron, along with the gravitational potential and attraction both inside and outside of the object, as well as the slope of its surface. Then we use our code to find the internal, external, and surface gravitational fields of the Platonic solids, asteroid (216) Kleopatra, and comet 67P/Churyumov-Gerasimenko, as well as their surface slopes and their self-gravitational energies. We also present simple spherical, ellipsoidal, cuboidal, and duplex models of Kleopatra and comet 67P, and show how to generalize our methods to inhomogeneous objects and magnetic fields. At present, only the self-energies of spheres, ellipsoids, and cuboids (boxes) are known analytically (or semi-analytically). The Supplementary Material contours the central potential and self-energy of homogeneous ellipsoids and cuboids of all aspect ratios, and also analytically the self-gravitational energy of a "duplex" consisting of two coupled spheres. The duplex is a good model for "contact binary" comets and asteroids; in fact, most comets seem to be bilobate, and might be described better as "dirty snowmen" than as "dirty snowballs".

  1. Color-Blindness Study: Color Discrimination on the TICCIT System.

    ERIC Educational Resources Information Center

    Asay, Calvin S.; Schneider, Edward W.

    The question studied whether the specific seven TICCIT system colors used within color coding schemes can be a source of confusion, or not seen at all, by the color-blind segment of target populations. Subjects were 11 color-blind and three normally sighted students at Brigham Young University. After a preliminary training exercise to acquaint the…

  2. Mapping the literature of diagnostic medical sonography.

    PubMed Central

    Walcott, B M

    1999-01-01

    Diagnostic medical sonography has been evolving as a recognized allied health occupation since the early 1970s, but no bibliometric studies of the literature of the field have been published. This study, part of the Medical Library Association Nursing and Allied Health Resources Section's Project for Mapping the Literature of Allied Health, attempted to identify the core journals in diagnostic medical sonography and determine how well these journals are indexed by MEDLINE, EMBASE/Excerpta Medica, and the Cumulative Index to Nursing and Allied Health Literature (CINAHL). Citation analysis was done using the three journals listed for the field by the Brandon/Hill list. Characteristics of two of these three journals affected the results to the extent that more data should be gathered to reach conclusions about the literature of diagnostic medical sonography as a whole. Results of the analysis do suggest that the literature of echocardiography, which is a special area of diagnostic medical sonography, is indexed much more completely by MEDLINE and EMBASE/Excerpta Medica than by CINAHL. Suggestions are made for librarians making collection development decisions in this area of allied health. PMID:10427429

  3. Terminology for contrast-enhanced sonography: a practical glossary.

    PubMed

    Catalano, Orlando; Migaleddu, Vincenzo; Quaia, Emilio; Caruso, Giuseppe

    2007-06-01

    The purpose of this glossary is to offer an updated guide to the correct terminology for contrast-enhanced sonography. This report was prepared by a panel of radiologists from the Sonography Section of the Italian Association of Medical Radiology. A leading author prepared a list of terms based on a comprehensive literature survey. The draft was analyzed by 3 experts on the topic of contrast-enhanced sonography. These reviewers reached a consensus and prepared the final version. A list of 137 terms is included. These terms are briefly defined. Their proper application is discussed, with special reference to potential misleading uses. Contrast-enhanced sonography is a relatively new diagnostic tool, now entering clinical practice in several countries. Use of appropriate, universal terminology is mandatory in the scientific setting to allow comparison between different published experiences. Additionally, use of clear, standardized terminology is necessary in the clinical setting to facilitate report understanding by the referring physician. Standardized, nonequivocal nomenclature may also help future diffusion of sonographic contrast media in countries where their application is still not approved.

  4. Human V4 Activity Patterns Predict Behavioral Performance in Imagery of Object Color.

    PubMed

    Bannert, Michael M; Bartels, Andreas

    2018-04-11

    Color is special among basic visual features in that it can form a defining part of objects that are engrained in our memory. Whereas most neuroimaging research on human color vision has focused on responses related to external stimulation, the present study investigated how sensory-driven color vision is linked to subjective color perception induced by object imagery. We recorded fMRI activity in male and female volunteers during viewing of abstract color stimuli that were red, green, or yellow in half of the runs. In the other half we asked them to produce mental images of colored, meaningful objects (such as tomato, grapes, banana) corresponding to the same three color categories. Although physically presented color could be decoded from all retinotopically mapped visual areas, only hV4 allowed predicting colors of imagined objects when classifiers were trained on responses to physical colors. Importantly, only neural signal in hV4 was predictive of behavioral performance in the color judgment task on a trial-by-trial basis. The commonality between neural representations of sensory-driven and imagined object color and the behavioral link to neural representations in hV4 identifies area hV4 as a perceptual hub linking externally triggered color vision with color in self-generated object imagery. SIGNIFICANCE STATEMENT Humans experience color not only when visually exploring the outside world, but also in the absence of visual input, for example when remembering, dreaming, and during imagery. It is not known where neural codes for sensory-driven and internally generated hue converge. In the current study we evoked matching subjective color percepts, one driven by physically presented color stimuli, the other by internally generated color imagery. This allowed us to identify area hV4 as the only site where neural codes of corresponding subjective color perception converged regardless of its origin. Color codes in hV4 also predicted behavioral performance in an imagery task, suggesting it forms a perceptual hub for color perception. Copyright © 2018 the authors 0270-6474/18/383657-12$15.00/0.

  5. Patients' ideas, expectations and experience with self operated endovaginal telemonitoring: a prospective pilot study.

    PubMed

    Verdonckt, S; Gerris, J

    2017-09-01

    To examine advantages and disadvantages as perceived by patients and their partners using home sonography for monitoring ovarian stimulation prior to artificial fertility treatment. We interviewed 25 patients and their partners and took 44 online questionnaires. All interviews were written out and the transcripts were coded, based on words patients used to describe their experience. The query consisted mostly of statements, of which the participant had to ascertain whether or not they agreed (1= I absolutely don't agree and 5 = I absolutely agree). The median and mean of agreement scores was calculated. The time saving and practical aspect of self-operated endo-vaginal tele-monitoring (SOET) was the most important argument to choose SOET. In addition, the following aspects were considered advantages: more autonomy, no need for leave from work, a better doctor-patient relationship and sometimes more involvement of the partner. The most important disadvantage is a sense of initial insecurity couples experience during the first ultrasound. Almost all couples experience this, but they accept it as part of the process. Using SOET was a pleasant experience for all couples. All patients and partners had positive expectations about SOET. The initial insecurity can be minimized, by improving teaching measures. It would be positive if a legal framework is set up allowing reimbursement of home sonography.

  6. Color Comprehension and Color Categories among Blind Students: A Multi-Sensory Approach in Implementing Concrete Language to Include All Students in Advanced Writing Classes

    ERIC Educational Resources Information Center

    Antarasena, Salinee

    2009-01-01

    This study investigates teaching methods regarding color comprehension and color categorization among blind students, as compared to their non-blind peers and whether they understand and represent the same color comprehension and color categories. Then after digit codes for color comprehension teaching and assistive technology for the blind had…

  7. Modeling of rolling element bearing mechanics. Theoretical manual

    NASA Technical Reports Server (NTRS)

    Merchant, David H.; Greenhill, Lyn M.

    1994-01-01

    This report documents the theoretical basis for the Rolling Element Bearing Analysis System (REBANS) analysis code which determines the quasistatic response to external loads or displacement of three types of high-speed rolling element bearings: angular contact ball bearings; duplex angular contact ball bearings; and cylindrical roller bearings. The model includes the effects of bearing ring and support structure flexibility. It is comprised of two main programs: the Preprocessor for Bearing Analysis (PREBAN) which creates the input files for the main analysis program; and Flexibility Enhanced Rolling Element Bearing Analysis (FEREBA), the main analysis program. A companion report addresses the input instructions for and features of the computer codes. REBANS extends the capabilities of the SHABERTH (Shaft and Bearing Thermal Analysis) code to include race and housing flexibility, including such effects as dead band and preload springs.

  8. Aptamer-fluorescent silica nanoparticles bioconjugates based dual-color flow cytometry for specific detection of Staphylococcus aureus.

    PubMed

    He, Xiaoxiao; Li, Yuhong; He, Dinggen; Wang, Kemin; Shangguan, Jingfang; Shi, Hui

    2014-07-01

    This paper describes a sensitive and specific determination strategy for Staphylococcus aureus (S. aureus) detection using aptamer recognition and fluorescent silica nanoparticles (FSiNPs) label based dual-color flow cytometry assay (Aptamer/FSiNPs-DCFCM). In the protocol, an aptamer, having high affinity to S. aureus, was first covalently immobilized onto chloropropyl functionalized FSiNPs through a click chemistry approach to generate aptamer-nanoparticles bioconjugates (Aptamer/FSiNPs). Next, S. aureus was incubated with Aptamer/FSiNPs, and then stained with SYBR Green I (a special staining material for the duplex DNA). Upon target binding and nucleic acid staining with SYBR Green I, the S. aureus was determined using two-color flow cytometry. The method took advantage of the specificity of aptamer, signal amplification of FSiNPs label and decreased false positives of two-color flow cytometry assay. It was demonstrated that these Aptamer/FSiNPs could efficiently recognize and fluorescently label target S. aureus. Through multiparameter determination with flow cytometry, this assay allowed for detection of as low as 1.5 x 10(2) and 7.6 x 10(2) cells mL(-1) S. aureus in buffer and spiked milk, respectively, with higher sensitivity than the Aptamer/FITC based flow cytometry.

  9. Application of computer generated color graphic techniques to the processing and display of three dimensional fluid dynamic data

    NASA Technical Reports Server (NTRS)

    Anderson, B. H.; Putt, C. W.; Giamati, C. C.

    1981-01-01

    Color coding techniques used in the processing of remote sensing imagery were adapted and applied to the fluid dynamics problems associated with turbofan mixer nozzles. The computer generated color graphics were found to be useful in reconstructing the measured flow field from low resolution experimental data to give more physical meaning to this information and in scanning and interpreting the large volume of computer generated data from the three dimensional viscous computer code used in the analysis.

  10. A Computer-Aided Diagnosis System for Breast Cancer Combining Digital Mammography and Genomics

    DTIC Science & Technology

    2006-05-01

    Huang, "Breast cancer diagnosis using self-organizing map for sonography." Ultrasound Med. Biol. 26, 405 (2000). 20 K. Horsch, M.L. Giger, L.A. Venta ...L.A. Venta , "Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography." Acad Radiol 11, 272 (2004). 22 W. Chen...418. 27. Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography

  11. Compression of color-mapped images

    NASA Technical Reports Server (NTRS)

    Hadenfeldt, A. C.; Sayood, Khalid

    1992-01-01

    In a standard image coding scenario, pixel-to-pixel correlation nearly always exists in the data, especially if the image is a natural scene. This correlation is what allows predictive coding schemes (e.g., DPCM) to perform efficient compression. In a color-mapped image, the values stored in the pixel array are no longer directly related to the pixel intensity. Two color indices which are numerically adjacent (close) may point to two very different colors. The correlation still exists, but only via the colormap. This fact can be exploited by sorting the color map to reintroduce the structure. The sorting of colormaps is studied and it is shown how the resulting structure can be used in both lossless and lossy compression of images.

  12. [MRI evaluation of placenta accreta treated by embolization. Apropos of a case. Review of the literature].

    PubMed

    Lemercier, E; Genevois, A; Descargue, G; Clavier, E; Benozio, M

    1999-04-01

    Placenta accreta results from an abnormal attachment of the placenta to the uterine myometrium. The reported incidence in literature is variable, with an average of 1/7000 pregnancies. This condition is associated with a significant risk of bleeding at the time of delivery, usually requiring hysterectomy. Sonography associated with color Doppler is useful for diagnosis, but MRI can be used successfully to evaluate the degree of placental tissue invading into the myometrium, the serosa, and for follow-up after conservative management. To our knowledge, only two cases of placenta accreta evaluated with MR and six cases of placenta accreta treated by embolization have been reported in the literature. The authors report one case of placenta accreta treated successfully by embolization, and followed-up by MRI.

  13. [Sonography of the eye and orbit with a multipurpose ultrasound unit].

    PubMed

    Bergès, O; Koskas, P; Lafitte, F; Piekarski, J-D

    2006-04-01

    Our goal is to help echographists and radiologists become familiar with the various possibilities indications, technique and results of ophtalmic ultrasonography. We used a multipurpose ultrasound unit. The frequency of the transducer has to be equal or superior to 7.5 MHz. Color Doppler allowing the study of low flows is useful. The study must be standardized: the first step is to obtain measurements of both eyes. Then the entire globe is systematically evaluated. Finally, the orbital structures and vessels of the eye and orbit are analized. After a review of the anatomy and the normal sonographic features, the main indications are described as well as the main pathologies. Special attention is paid to intravitreal hemorrhage, retinal and choroidal detachments, intraocular tumors and orbital space occupying lesions.

  14. Opto-acoustic breast imaging with co-registered ultrasound

    NASA Astrophysics Data System (ADS)

    Zalev, Jason; Clingman, Bryan; Herzog, Don; Miller, Tom; Stavros, A. Thomas; Oraevsky, Alexander; Kist, Kenneth; Dornbluth, N. Carol; Otto, Pamela

    2014-03-01

    We present results from a recent study involving the ImagioTM breast imaging system, which produces fused real-time two-dimensional color-coded opto-acoustic (OA) images that are co-registered and temporally inter- leaved with real-time gray scale ultrasound using a specialized duplex handheld probe. The use of dual optical wavelengths provides functional blood map images of breast tissue and tumors displayed with high contrast based on total hemoglobin and oxygen saturation of the blood. This provides functional diagnostic information pertaining to tumor metabolism. OA also shows morphologic information about tumor neo-vascularity that is complementary to the morphological information obtained with conventional gray scale ultrasound. This fusion technology conveniently enables real-time analysis of the functional opto-acoustic features of lesions detected by readers familiar with anatomical gray scale ultrasound. We demonstrate co-registered opto-acoustic and ultrasonic images of malignant and benign tumors from a recent clinical study that provide new insight into the function of tumors in-vivo. Results from the Feasibility Study show preliminary evidence that the technology may have the capability to improve characterization of benign and malignant breast masses over conventional diagnostic breast ultrasound alone and to improve overall accuracy of breast mass diagnosis. In particular, OA improved speci city over that of conventional diagnostic ultrasound, which could potentially reduce the number of negative biopsies performed without missing cancers.

  15. Successful Resection of a Large Carotid Body Tumor Masquerading Complete Encasement of the Internal Carotid Artery on Preoperative Imaging.

    PubMed

    Kakkos, Stavros K; Zampakis, Peter; Lampropoulos, George C; Paridis, Leonidas; Kaplanis, Charalampos; Bantouna, Dimitra; Nikolakopoulos, Konstantinos M; Papageorgopoulou, Chrysanthi P; Kalogeropoulou, Christina; Tsolakis, Ioannis A

    2018-05-01

    A 41-year-old woman presented with a large painful and tender mass of the left side of her neck located just below the angle of the mandible. She was also complaining of frequent attacks of symptoms ranging from dizziness upon resuming the erect position to frank syncope. Color-coded duplex showed a large well-vascularized vascular mass at the level of the carotid bifurcation, suggesting the diagnosis of a carotid body tumor (CBT). A computerized tomographic angiography confirmed the diagnosis of a CBT, which measured 5.7 cm in its craniocaudal axis. The tumor appeared to encase the internal carotid artery (ICA) at the level of its origin, indicating the presence of a Shamblin group 3 tumor. During surgery, the CBT seemingly encased the ICA; however, it was successfully taken off the ICA, by establishing an adventitial dissection place, obviating the need for arterial resection and replacement. A brief intraoperative episode of cardiac arrest was successfully managed. Postoperative course was uneventful, and all symptoms were cured. Pathology confirmed the clinical diagnosis and did not show malignancy. In conclusion, meticulous surgical techniques can spare the ICA from removal or inadvertent injury during CBT surgery and reduce the morbidity often associated with the resection of large or advanced tumors but also cure atypical patient symptoms.

  16. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  17. Accessible and informative sectioned images, color-coded images, and surface models of the ear.

    PubMed

    Park, Hyo Seok; Chung, Min Suk; Shin, Dong Sun; Jung, Yong Wook; Park, Jin Seo

    2013-08-01

    In our previous research, we created state-of-the-art sectioned images, color-coded images, and surface models of the human ear. Our ear data would be more beneficial and informative if they were more easily accessible. Therefore, the purpose of this study was to distribute the browsing software and the PDF file in which ear images are to be readily obtainable and freely explored. Another goal was to inform other researchers of our methods for establishing the browsing software and the PDF file. To achieve this, sectioned images and color-coded images of ear were prepared (voxel size 0.1 mm). In the color-coded images, structures related to hearing, equilibrium, and structures originated from the first and second pharyngeal arches were segmented supplementarily. The sectioned and color-coded images of right ear were added to the browsing software, which displayed the images serially along with structure names. The surface models were reconstructed to be combined into the PDF file where they could be freely manipulated. Using the browsing software and PDF file, sectional and three-dimensional shapes of ear structures could be comprehended in detail. Furthermore, using the PDF file, clinical knowledge could be identified through virtual otoscopy. Therefore, the presented educational tools will be helpful to medical students and otologists by improving their knowledge of ear anatomy. The browsing software and PDF file can be downloaded without charge and registration at our homepage (http://anatomy.dongguk.ac.kr/ear/). Copyright © 2013 Wiley Periodicals, Inc.

  18. Chromatic aberration and the roles of double-opponent and color-luminance neurons in color vision.

    PubMed

    Vladusich, Tony

    2007-03-01

    How does the visual cortex encode color? I summarize a theory in which cortical double-opponent color neurons perform a role in color constancy and a complementary set of color-luminance neurons function to selectively correct for color fringes induced by chromatic aberration in the eye. The theory may help to resolve an ongoing debate concerning the functional properties of cortical receptive fields involved in color coding.

  19. Bilayer Protograph Codes for Half-Duplex Relay Channels

    NASA Technical Reports Server (NTRS)

    Divsalar, Dariush; VanNguyen, Thuy; Nosratinia, Aria

    2013-01-01

    Direct to Earth return links are limited by the size and power of lander devices. A standard alternative is provided by a two-hops return link: a proximity link (from lander to orbiter relay) and a deep-space link (from orbiter relay to Earth). Although direct to Earth return links are limited by the size and power of lander devices, using an additional link and a proposed coding for relay channels, one can obtain a more reliable signal. Although significant progress has been made in the relay coding problem, existing codes must be painstakingly optimized to match to a single set of channel conditions, many of them do not offer easy encoding, and most of them do not have structured design. A high-performing LDPC (low-density parity-check) code for the relay channel addresses simultaneously two important issues: a code structure that allows low encoding complexity, and a flexible rate-compatible code that allows matching to various channel conditions. Most of the previous high-performance LDPC codes for the relay channel are tightly optimized for a given channel quality, and are not easily adapted without extensive re-optimization for various channel conditions. This code for the relay channel combines structured design and easy encoding with rate compatibility to allow adaptation to the three links involved in the relay channel, and furthermore offers very good performance. The proposed code is constructed by synthesizing a bilayer structure with a pro to graph. In addition to the contribution to relay encoding, an improved family of protograph codes was produced for the point-to-point AWGN (additive white Gaussian noise) channel whose high-rate members enjoy thresholds that are within 0.07 dB of capacity. These LDPC relay codes address three important issues in an integrative manner: low encoding complexity, modular structure allowing for easy design, and rate compatibility so that the code can be easily matched to a variety of channel conditions without extensive re-optimization. The main problem of half-duplex relay coding can be reduced to the simultaneous design of two codes at two rates and two SNRs (signal-to-noise ratios), such that one is a subset of the other. This problem can be addressed by forceful optimization, but a clever method of addressing this problem is via the bilayer lengthened (BL) LDPC structure. This method uses a bilayer Tanner graph to make the two codes while using a concept of "parity forwarding" with subsequent successive decoding that removes the need to directly address the issue of uneven SNRs among the symbols of a given codeword. This method is attractive in that it addresses some of the main issues in the design of relay codes, but it does not by itself give rise to highly structured codes with simple encoding, nor does it give rate-compatible codes. The main contribution of this work is to construct a class of codes that simultaneously possess a bilayer parity- forwarding mechanism, while also benefiting from the properties of protograph codes having an easy encoding, a modular design, and being a rate-compatible code.

  20. Anodizing color coded anodized Ti6Al4V medical devices for increasing bone cell functions

    PubMed Central

    Ross, Alexandra P; Webster, Thomas J

    2013-01-01

    Current titanium-based implants are often anodized in sulfuric acid (H2SO4) for color coding purposes. However, a crucial parameter in selecting the material for an orthopedic implant is the degree to which it will integrate into the surrounding bone. Loosening at the bone–implant interface can cause catastrophic failure when motion occurs between the implant and the surrounding bone. Recently, a different anodization process using hydrofluoric acid has been shown to increase bone growth on commercially pure titanium and titanium alloys through the creation of nanotubes. The objective of this study was to compare, for the first time, the influence of anodizing a titanium alloy medical device in sulfuric acid for color coding purposes, as is done in the orthopedic implant industry, followed by anodizing the device in hydrofluoric acid to implement nanotubes. Specifically, Ti6Al4V model implant samples were anodized first with sulfuric acid to create color-coding features, and then with hydrofluoric acid to implement surface features to enhance osteoblast functions. The material surfaces were characterized by visual inspection, scanning electron microscopy, contact angle measurements, and energy dispersive spectroscopy. Human osteoblasts were seeded onto the samples for a series of time points and were measured for adhesion and proliferation. After 1 and 2 weeks, the levels of alkaline phosphatase activity and calcium deposition were measured to assess the long-term differentiation of osteoblasts into the calcium depositing cells. The results showed that anodizing in hydrofluoric acid after anodizing in sulfuric acid partially retains color coding and creates unique surface features to increase osteoblast adhesion, proliferation, alkaline phosphatase activity, and calcium deposition. In this manner, this study provides a viable method to anodize an already color coded, anodized titanium alloy to potentially increase bone growth for numerous implant applications. PMID:23319862

  1. Hybrid 3D visualization of the chest and virtual endoscopy of the tracheobronchial system: possibilities and limitations of clinical application.

    PubMed

    Seemann, M D; Claussen, C D

    2001-06-01

    A hybrid rendering method which combines a color-coded surface rendering method and a volume rendering method is described, which enables virtual endoscopic examinations using different representation models. 14 patients with malignancies of the lung and mediastinum (n=11) and lung transplantation (n=3) underwent thin-section spiral computed tomography. The tracheobronchial system and anatomical and pathological features of the chest were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures. For the virtual endoscopy of the tracheobronchial system, a shaded-surface model without color coding, a transparent color-coded shaded-surface model and a triangle-surface model were tested and compared. The hybrid rendering technique exploit the advantages of both rendering methods, provides an excellent overview of the tracheobronchial system and allows a clear depiction of the complex spatial relationships of anatomical and pathological features. Virtual bronchoscopy with a transparent color-coded shaded-surface model allows both a simultaneous visualization of an airway, an airway lesion and mediastinal structures and a quantitative assessment of the spatial relationship between these structures, thus improving confidence in the diagnosis of endotracheal and endobronchial diseases. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images. Virtual bronchoscopy with a transparent color-coded shaded-surface model offers a practical alternative to fiberoptic bronchoscopy and is particularly promising for patients in whom fiberoptic bronchoscopy is not feasible, contraindicated or refused. Furthermore, it can be used as a complementary procedure to fiberoptic bronchoscopy in evaluating airway stenosis and guiding bronchoscopic biopsy, surgical intervention and palliative therapy and is likely to be increasingly accepted as a screening method for people with suspected endobronchial malignancy and as control examination in the aftercare of patients with malignant diseases.

  2. A new definition for an old entity: improved definition of mitral valve prolapse using three-dimensional echocardiography and color-coded parametric models.

    PubMed

    Addetia, Karima; Mor-Avi, Victor; Weinert, Lynn; Salgo, Ivan S; Lang, Roberto M

    2014-01-01

    Differentiating between mitral valve (MV) prolapse (MVP) and MV billowing (MVB) on two-dimensional echocardiography is challenging. The aim of this study was to test the hypothesis that color-coded models of maximal leaflet displacement from the annular plane into the atrium derived from three-dimensional transesophageal echocardiography would allow discrimination between these lesions. Three-dimensional transesophageal echocardiographic imaging of the MV was performed in 50 patients with (n = 38) and without (n = 12) degenerative MV disease. Definitive diagnosis of MVP versus MVB was made using inspection of dynamic three-dimensional renderings and multiple two-dimensional cut planes extracted from three-dimensional data sets. This was used as a reference standard to test an alternative approach, wherein the color-coded parametric models were inspected for integrity of the coaptation line and location of the maximally displaced portion of the leaflet. Diagnostic interpretations of these models by two independent readers were compared with the reference standard. In all cases of MVP, the color-coded models depicted loss of integrity of the coaptation line and maximal leaflet displacement extending to the coaptation line. MVB was depicted by preserved leaflet apposition with maximal displacement away from the coaptation line. Interpretation of the 50 color-coded models by novice readers took 5 to 10 min and resulted in good agreement with the reference technique (κ = 0.81 and κ = 0.73 for the two readers). Three-dimensional color-coded models provide a static display of MV leaflet displacement, allowing differentiation between MVP and MVB, without the need to inspect multiple planes and while taking into account the saddle shape of the mitral annulus. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  3. Anodizing color coded anodized Ti6Al4V medical devices for increasing bone cell functions.

    PubMed

    Ross, Alexandra P; Webster, Thomas J

    2013-01-01

    Current titanium-based implants are often anodized in sulfuric acid (H(2)SO(4)) for color coding purposes. However, a crucial parameter in selecting the material for an orthopedic implant is the degree to which it will integrate into the surrounding bone. Loosening at the bone-implant interface can cause catastrophic failure when motion occurs between the implant and the surrounding bone. Recently, a different anodization process using hydrofluoric acid has been shown to increase bone growth on commercially pure titanium and titanium alloys through the creation of nanotubes. The objective of this study was to compare, for the first time, the influence of anodizing a titanium alloy medical device in sulfuric acid for color coding purposes, as is done in the orthopedic implant industry, followed by anodizing the device in hydrofluoric acid to implement nanotubes. Specifically, Ti6Al4V model implant samples were anodized first with sulfuric acid to create color-coding features, and then with hydrofluoric acid to implement surface features to enhance osteoblast functions. The material surfaces were characterized by visual inspection, scanning electron microscopy, contact angle measurements, and energy dispersive spectroscopy. Human osteoblasts were seeded onto the samples for a series of time points and were measured for adhesion and proliferation. After 1 and 2 weeks, the levels of alkaline phosphatase activity and calcium deposition were measured to assess the long-term differentiation of osteoblasts into the calcium depositing cells. The results showed that anodizing in hydrofluoric acid after anodizing in sulfuric acid partially retains color coding and creates unique surface features to increase osteoblast adhesion, proliferation, alkaline phosphatase activity, and calcium deposition. In this manner, this study provides a viable method to anodize an already color coded, anodized titanium alloy to potentially increase bone growth for numerous implant applications.

  4. Plant MicroRNA Prediction by Supervised Machine Learning Using C5.0 Decision Trees.

    PubMed

    Williams, Philip H; Eyles, Rod; Weiller, Georg

    2012-01-01

    MicroRNAs (miRNAs) are nonprotein coding RNAs between 20 and 22 nucleotides long that attenuate protein production. Different types of sequence data are being investigated for novel miRNAs, including genomic and transcriptomic sequences. A variety of machine learning methods have successfully predicted miRNA precursors, mature miRNAs, and other nonprotein coding sequences. MirTools, mirDeep2, and miRanalyzer require "read count" to be included with the input sequences, which restricts their use to deep-sequencing data. Our aim was to train a predictor using a cross-section of different species to accurately predict miRNAs outside the training set. We wanted a system that did not require read-count for prediction and could therefore be applied to short sequences extracted from genomic, EST, or RNA-seq sources. A miRNA-predictive decision-tree model has been developed by supervised machine learning. It only requires that the corresponding genome or transcriptome is available within a sequence window that includes the precursor candidate so that the required sequence features can be collected. Some of the most critical features for training the predictor are the miRNA:miRNA(∗) duplex energy and the number of mismatches in the duplex. We present a cross-species plant miRNA predictor with 84.08% sensitivity and 98.53% specificity based on rigorous testing by leave-one-out validation.

  5. A synchronous serial bus for multidimensional array acoustic logging tool

    NASA Astrophysics Data System (ADS)

    Men, Baiyong; Ju, Xiaodong; Lu, Junqiang; Qiao, Wenxiao

    2016-12-01

    In high-temperature and spatial borehole applications, a distributed structure is employed in a multidimensional array acoustic logging tool (MDALT) based on a phased array technique for electronic systems. However, new challenges, such as synchronous multichannel data acquisition, multinode real-time control and bulk data transmission in a limited interval, have emerged. To address these challenges, we developed a synchronous serial bus (SSB) in this study. SSB works in a half-duplex mode via a master-slave architecture. It also consists of a single master, several slaves, a differential clock line and a differential data line. The clock line is simplex, whereas the data line is half-duplex and synchronous to the clock line. A reliable communication between the master and the slaves with real-time adjustment of synchronisation is achieved by rationally designing the frame format and protocol of communication and by introducing a scramble code and a Hamming error-correcting code. The control logic of the master and the slaves is realized in field programmable gate array (FPGA) or complex programmable logic device (CPLD). The clock speed of SSB is 10 MHz, the effective data rate of the bulk data transmission is over 99%, and the synchronous errors amongst the slaves are less than 10 ns. Room-temperature test, high-temperature test (175 °C) and field test demonstrate that the proposed SSB is qualified for MDALT.

  6. Perfusion status of the stroke-like lesion at the hyperacute stage in MELAS.

    PubMed

    Yeh, Hsu-Ling; Chen, Yen-Kung; Chen, Wei-Hung; Wang, Han-Cheng; Chiu, Hou-Chang; Lien, Li-Ming; Wei, Yau-Huei

    2013-02-01

    Hypoperfusion on single-photon emission computed tomography (SPECT) of the stroke-like lesion (SLL) at the hyperacute stage of mitochondrial encephalopathy with lactic acidosis and stroke-like episodes (MELAS) is considered to be a supportive evidence of the mitochondrial angiopathy theory. Our objectives were to examine whether other neuroimages, especially transcranial color-coded sonography (TCCS), done at the hyperacute stage of stroke-like episode (SLE) is consistent with hypoperfusion of the SLL. We reviewed the magnetic resonance imaging (MRI), SPECT, cerebral angiography, and TCCS of a patient with MELAS syndrome, all of which were performed at the hyperacute stage of one SLE. MRI on the 1st day post SLE showed right temporoparietal lesion with vasogenic edema. SPECT on the 2nd day showed focal decreased uptake of technetium-99m hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) in the same region, but cerebral angiography and TCCS on the 3rd day showed increased regional cerebral blood flow (rCBF) and distal arteriole dilation in the same region. TCCS can delineate increased rCBF of the SLL at the hyperacute stage of SLE. We propose that the discrepancy between the decreased (99m)Tc-HMPAO uptake and increased rCBF might be caused by mitochondrial dysfunction. The phenomenon of "hypoperfusion" on SPECT might be caused by cell dysfunction but not decreased rCBF. We suggest that SPECT can be complemented by angiography and TCCS in future studies to delineate the perfusion status of SLLs. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  7. Effect of radiographic contrast media on renal perfusion - First results.

    PubMed

    Lamby, P; Jung, F; Falter, J; Mrowietz, C; Graf, S; Schellenberg, L; Platz Batista da Silva, N; Prantl, L; Franke, R P; Jung, E M

    2016-01-01

    Intra-arterial administration of radiographic contrast media (CM) is discussed to impair renal perfusion. The pathogenesis of contrast-induced Nephropathy (CIN) is still not clarified. This trial was performed to prove the effects of two CM with different molecular structure on renal perfusion. A prospective, randomized study on 16 pigs was designed to compare the outcome after application of a low-osmolar iodinated CM (770 mOsm/kg H2O - Group1) and an iso-osmolar iodinated CM (290 mOsm/kg H2o - Group2).Color Coded Doppler Sonography (LOGIQ E9, GE, Milwaukee, USA) was applied for measuring the Renal Resistive Index (RRI) before and after the first, fifth, and tenth bolus of CM. Statistics was performed using analysis of variance for repeated measurements with the Factor "CM". All flow spectra were documented free of artifacts and Peak Systolic Velocity (PSV), Enddiastolic Velocity (EDV) and RRI respectively could be calculated. Mean PSV in Group 1 led to a decrease while in Group 2 PSV showed a significant increase after CM (p = 0,042). The course of the mean EDV in both groups deferred accordingly (p = 0,033). Mean RRI over time significantly deferred in both groups (p = 0,001). It showed a biphasic course in Group 2 and a decrease over time in Group 2. While iso-osmolar CM induced an increase of PSV and EDV together with a decrease of RRI, low-osmolar CM could not show this effect or rather led to the opposite.

  8. Perceptions of drug color among drug sellers and consumers in rural southwestern Nigeria.

    PubMed

    Brieger, William R; Salami, Kabiru K; Oshiname, Frederick O

    2007-09-01

    Color is commonly used for branding and coding consumer products including medications. People associate certain colors in tablets and capsules with the effect of the drug and the illness for which it is meant. Color coding was introduced in age-specific prepacked antimalarial drugs for preschool aged children in Nigeria by the National Malaria Control Committee. Yellow was designated for the younger ages and blue for the older. The National Malaria Control Committee did not perform market research to learn how their color codes would be perceived by consumers. The study aimed at determining perceptions of both consumers and sellers of medicines at the community level to learn about color likes and dislikes that might influence acceptance of new color-coded child prepacks of antimalarial drugs. Qualitative methods were used to determine perceptions of drug colors. A series of focus group interviews were conducted with male and female community members, and in-depth interviews were held with medicine sellers in the Igbo-Ora community in southwestern Nigeria. Respondents clearly associated medicines with their effects and purpose, for example white drugs for pain relief, red for building blood, blue to aid sleep, and yellow for malaria treatment. Medicine vendors had a low opinion of white colored medicines, but community members were ultimately more concerned about efficacy. The perceived association between yellow and malaria, because of local symptom perceptions of eyes turning yellowish during malaria, yielded a favorable response when consumers were shown the yellow prepacks. The response to blue was noncommittal but consumers indicated that if they were properly educated on the efficacy and function of the new drugs they would likely buy them. Community members will accept yellow as an antimalarial drug but health education will be needed for promoting the idea of blue for malaria and the notion of age-specific packets. Therefore, the strong medicine vendor-training component that accompanied roll out of these prepacks in the pilot states needs to be replicated nationally.

  9. Visualization and Analysis of Microtubule Dynamics Using Dual Color-Coded Display of Plus-End Labels

    PubMed Central

    Garrison, Amy K.; Xia, Caihong; Wang, Zheng; Ma, Le

    2012-01-01

    Investigating spatial and temporal control of microtubule dynamics in live cells is critical to understanding cell morphogenesis in development and disease. Tracking fluorescently labeled plus-end-tracking proteins over time has become a widely used method to study microtubule assembly. Here, we report a complementary approach that uses only two images of these labels to visualize and analyze microtubule dynamics at any given time. Using a simple color-coding scheme, labeled plus-ends from two sequential images are pseudocolored with different colors and then merged to display color-coded ends. Based on object recognition algorithms, these colored ends can be identified and segregated into dynamic groups corresponding to four events, including growth, rescue, catastrophe, and pause. Further analysis yields not only their spatial distribution throughout the cell but also provides measurements such as growth rate and direction for each labeled end. We have validated the method by comparing our results with ground-truth data derived from manual analysis as well as with data obtained using the tracking method. In addition, we have confirmed color-coded representation of different dynamic events by analyzing their history and fate. Finally, we have demonstrated the use of the method to investigate microtubule assembly in cells and provided guidance in selecting optimal image acquisition conditions. Thus, this simple computer vision method offers a unique and quantitative approach to study spatial regulation of microtubule dynamics in cells. PMID:23226282

  10. Cerebro-afferent vessel and pupillary basal diameter variation induced by stomatognathic trigeminal proprioception: a case report.

    PubMed

    De Cicco, Vincenzo

    2012-09-03

    A patient affected by asymmetric hemodynamics of cerebro-afferent vessels underwent duplex color scanner investigations in occlusal proprioceptive un- and rebalance conditions. Pupillometric video-oculographic examinations were performed in order to spot connected trigeminal proprioceptive motor patterns able to interfere on sympathetic autonomic activity. The aim of this case report is to verify if involuntary jaw closing during swallowing, executed in unbalance and rebalance myoelectric activity, would be able to modify cerebral hemodynamics. A 56-year-old Caucasian Italian woman affected by asymmetric blood flow of cerebro-afferent vessels underwent an electromyographic investigation of her occlusal muscles in order to assess their occlusal functional balance. The extreme asymmetry of myoelectric activity in dental occlusion evidenced by electromyographic values suggested the rebalancing of the functions of occlusal muscles through concurrent transcutaneous stimulation of the trigeminal nerve supra- and submandibular motor branches. The above-mentioned method allowed the detection of a symmetric craniomandibular muscular relation that can be kept constant through the use of a cusp bite modeled on the inferior dental arch: called orthotic-syntropic bite for its peculiar use of electrostimulation. A few days later, the patient underwent a duplex color scanner investigation and pupillometric video-oculographic examinations in occlusal unbalance and rebalance conditions. A comparative data analysis showed that an unbalanced dental occlusal function may represent an interferential pattern on cerebral hemodynamics velocity and pupillometric evaluations have proved useful both in the analysis of locus coeruleus functional modalities and as a diagnostic tool in the assessment of pathologies involving locus coeruleus and autonomic systems. The inclusion of myoelectric masseter examinations can be useful in patients with asymmetric hemodynamics of cerebro-afferent vessels and dental occlusal proprioceptive rebalance can integrate the complex therapy of patients with increased chronic sympathetic activity.

  11. Genetic mapping uncovers cis-regulatory landscape of RNA editing.

    PubMed

    Ramaswami, Gokul; Deng, Patricia; Zhang, Rui; Anna Carbone, Mary; Mackay, Trudy F C; Li, Jin Billy

    2015-09-16

    Adenosine-to-inosine (A-to-I) RNA editing, catalysed by ADAR enzymes conserved in metazoans, plays an important role in neurological functions. Although the fine-tuning mechanism provided by A-to-I RNA editing is important, the underlying rules governing ADAR substrate recognition are not well understood. We apply a quantitative trait loci (QTL) mapping approach to identify genetic variants associated with variability in RNA editing. With very accurate measurement of RNA editing levels at 789 sites in 131 Drosophila melanogaster strains, here we identify 545 editing QTLs (edQTLs) associated with differences in RNA editing. We demonstrate that many edQTLs can act through changes in the local secondary structure for edited dsRNAs. Furthermore, we find that edQTLs located outside of the edited dsRNA duplex are enriched in secondary structure, suggesting that distal dsRNA structure beyond the editing site duplex affects RNA editing efficiency. Our work will facilitate the understanding of the cis-regulatory code of RNA editing.

  12. A viscous solvent enables information transfer from gene-length nucleic acids in a model prebiotic replication cycle

    NASA Astrophysics Data System (ADS)

    He, Christine; Gállego, Isaac; Laughlin, Brandon; Grover, Martha A.; Hud, Nicholas V.

    2017-04-01

    Many hypotheses concerning the nature of early life assume that genetic information was once transferred through the template-directed synthesis of RNA, before the emergence of coded enzymes. However, attempts to demonstrate enzyme-free, template-directed synthesis of nucleic acids have been limited by 'strand inhibition', whereby transferring information from a template strand in the presence of its complementary strand is inhibited by the stability of the template duplex. Here, we use solvent viscosity to circumvent strand inhibition, demonstrating information transfer from a gene-length template (>300 nt) within a longer (545 bp or 3 kb) duplex. These results suggest that viscous environments on the prebiotic Earth, generated periodically by water evaporation, could have facilitated nucleic acid replication—particularly of long, structured sequences such as ribozymes. Our approach works with DNA and RNA, suggesting that viscosity-mediated replication is possible for a range of genetic polymers, perhaps even for informational polymers that may have preceded RNA.

  13. Real-time sonography to estimate muscle thickness: comparison with MRI and CT.

    PubMed

    Dupont, A C; Sauerbrei, E E; Fenton, P V; Shragge, P C; Loeb, G E; Richmond, F J

    2001-05-01

    We investigated the feasibility of using real-time sonography to measure muscle thickness. Clinically, this technique would be used to measure the thickness of human muscles in which intramuscular microstimulators have been implanted to treat or prevent disuse atrophy. Porcine muscles were implanted with microstimulators and imaged with sonography, MRI, and CT to assess image artifacts created by the microstimulators and to design protocols for image alignment between methods. Sonography and MRI were then used to image the deltoid and supraspinatus muscles of 6 healthy human subjects. Microstimulators could be imaged with all 3 methods, producing only small imaging artifacts. Muscle-thickness measurements agreed well between methods, particularly when external markers were used to precisely align the imaging planes. The correlation coefficients for sonographic and MRI measurements were 0.96 for the supraspinatus and 0.97 for the deltoid muscle. Repeated sonographic measurements had a low coefficient of variation: 2.3% for the supraspinatus and 3.1% for the deltoid muscle. Real-time sonography is a relatively simple and inexpensive method of accurately measuring muscle thickness as long as the operator adheres to a strict imaging protocol and avoids excessive pressure with the transducer. Copyright 2001 John Wiley & Sons, Inc.

  14. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study.

    PubMed

    Zavoreo, Iris; Vučićević, Vanja; Boras; Zadravec, Dijana; Bašić, Vanja; Kes; Ciliga, Dubravka; Gabrić, Dragana

    2017-03-01

    Burning mouth syndrome (BMS) is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. Also, the results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. By use of transcranial sonography of the brain parenchyma, substantia nigra , midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years) and 20 controls with chronic pain in the lumbosacral region (61.5±15). Statistical analysis was performed by use of Student t test with significance set at p<0.05. The results of this study have shown hypoechogenicity of the substantia nigra and midbrain raphe as well as hyperechogenicity of the brain nucleus in BMS patients (p<0,05) as compared to controls. Altered transcranial sonography findings of the brain parenchyma , midbrain raphe and brain nucl eus in patients with burning mouth syndrome might reflect central disturbances within this syndrome. Burning Mouth Syndrome; Transcranial Sonography; substantia nigra; Midbrain Raphe Nuclei; Red Nucleus.

  15. 7 CFR 28.525 - Symbols and code numbers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...

  16. 7 CFR 28.525 - Symbols and code numbers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...

  17. 7 CFR 28.525 - Symbols and code numbers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...

  18. 7 CFR 28.525 - Symbols and code numbers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...

  19. 7 CFR 28.525 - Symbols and code numbers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...

  20. Learning about Probability from Text and Tables: Do Color Coding and Labeling through an Interactive-User Interface Help?

    ERIC Educational Resources Information Center

    Clinton, Virginia; Morsanyi, Kinga; Alibali, Martha W.; Nathan, Mitchell J.

    2016-01-01

    Learning from visual representations is enhanced when learners appropriately integrate corresponding visual and verbal information. This study examined the effects of two methods of promoting integration, color coding and labeling, on learning about probabilistic reasoning from a table and text. Undergraduate students (N = 98) were randomly…

  1. Semiannual status report

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The work performed in the previous six months can be divided into three main cases: (1) transmission of images over local area networks (LAN's); (2) coding of color mapped (pseudo-color) images; and (3) low rate video coding. A brief overview of the work done in the first two areas is presented. The third item is reported in somewhat more detail.

  2. Ideal Positions: 3D Sonography, Medical Visuality, Popular Culture.

    PubMed

    Seiber, Tim

    2016-03-01

    As digital technologies are integrated into medical environments, they continue to transform the experience of contemporary health care. Importantly, medicine is increasingly visual. In the history of sonography, visibility has played an important role in accessing fetal bodies for diagnostic and entertainment purposes. With the advent of three-dimensional (3D) rendering, sonography presents the fetus visually as already a child. The aesthetics of this process and the resulting imagery, made possible in digital networks, discloses important changes in the relationship between technology and biology, reproductive health and political debates, and biotechnology and culture.

  3. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.

    1980-12-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function.

  4. High-resolution sonography for distinguishing neoplastic gallbladder polyps and staging gallbladder cancer.

    PubMed

    Kim, Jung Hoon; Lee, Jae Young; Baek, Jee Hyun; Eun, Hyo Won; Kim, Young Jae; Han, Joon Koo; Choi, Byung Ihn

    2015-02-01

    OBJECTIVE. The purposes of this study were to compare staging accuracy of high-resolution sonography (HRUS) with combined low- and high-MHz transducers with that of conventional sonography for gallbladder cancer and to investigate the differences in the imaging findings of neoplastic and nonneoplastic gallbladder polyps. MATERIALS AND METHODS. Our study included 37 surgically proven gallbladder cancer (T1a = 7, T1b = 2, T2 = 22, T3 = 6), including 15 malignant neoplastic polyps and 73 surgically proven polyps (neoplastic = 31, nonneoplastic = 42) that underwent HRUS and conventional transabdominal sonography. Two radiologists assessed T-category and predefined polyp findings on HRUS and conventional transabdominal sonography. Statistical analyses were performed using chi-square and McNemar tests. RESULTS. The diagnostic accuracy for the T category was T1a = 92-95%, T1b = 89-95%, T2 = 78-86%, and T3 = 84-89%, all with good agreement (κ = 0.642) using HRUS. The diagnostic accuracy for differentiating T1 from T2 or greater than T2 was 92% and 89% on HRUS and 65% and 70% with conventional transabdominal sonography. Statistically common findings for neoplastic polyps included size greater than 1 cm, single lobular surface, vascular core, hypoechoic polyp, and hypoechoic foci (p < 0.05). The value of HRUS in the differential diagnosis of a gallbladder polyp was more clearly depicted internal echo foci than conventional transabdominal sonography (39 vs 21). A polyp size greater than 1 cm was independently associated with a neoplastic polyp (odds ratio = 7.5, p = 0.02). The AUC of a polyp size greater than 1 cm was 0.877. The sensitivity and specificity were 66.67% and 89.13%, respectively. CONCLUSION. HRUS is a simple method that enables accurate T categorization of gallbladder carcinoma. It provides high-resolution images of gallbladder polyps and may have a role in stratifying the risk for malignancy.

  5. Real-time virtual sonography, a coordinated sonography and MRI system that uses magnetic navigation, improves the sonographic identification of enhancing lesions on breast MRI.

    PubMed

    Nakano, Shogo; Yoshida, Miwa; Fujii, Kimihito; Yorozuya, Kyoko; Kousaka, Junko; Mouri, Yukako; Fukutomi, Takashi; Ohshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo

    2012-01-01

    This study verified that recently developed real-time virtual sonography (RVS) to coordinate a sonography image and the magnetic resonance imaging (MRI) multiplanar reconstruction (MPR) with magnetic navigation was useful. The purpose of this study was to evaluate the accuracy of RVS to sonographically identify enhancing lesions by breast MRI. Between December 2008 and May 2009, RVS was performed in 51 consecutive patients with 63 enhancing lesions. MRI was performed with the patients in the supine position using a 1.5-T imager with a body surface coil to achieve the same position as with sonography. To assess the accuracy of the RVS, the following three issues were analyzed: (i) The sonographic detection rate of enhancing lesions, (ii) the comparison of the tumor size measured by sonography and the MRI-MPR and (iii) the positioning errors as the distance from the actual sonographic position to the expected MRI position in 3-D. Among the 63 enhancing lesions, 42 (67%) lesions were identified by conventional B-mode, whereas the remaining 21 (33%) initial conventional B-mode occult lesions were identified by RVS alone. The sonographic size of the lesions detected by RVS alone was significantly smaller than that of lesions detected by conventional B-mode (p < 0.001). The mean tumor size provided by RVS was 12.3 mm for real-time sonography and 14.1 mm for MRI-MPR (r = 0.848, p < 0.001). The mean positioning errors for the transverse and sagittal planes and the depth from the skin were 7.7, 6.9 and 2.8 mm, respectively. The overall mean 3D positioning error was 12.0 mm. Our results suggest that RVS has good targeting accuracy to directly compare a sonographic image with MRI results without operator dependence. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. A novel approach to evaluating the benefit of post-urinary tract infection renal ultrasonography, using decision curve analysis.

    PubMed

    Harper, Luke; Delforge, Xavier; Maurin, Sophie; Leroy, Valerie; Michel, Jean-Luc; Sauvat, Frederique; Ferdynus, Cyril

    2016-10-01

    The benefit of post-urinary tract infection (UTI) sonography to detect clinically significant renal abnormalities remains a subject open to debate. Decision curve analysis (DCA) is a novel method for evaluating the clinical usefulness of diagnostic tests. Our objective was to determine, using DCA, the benefit of post-UTI sonography and of post-UTI sonography with biological markers of inflammation to predict the risk of recurrence of febrile UTI in children aged 2 to 24 months without known uropathy. We retrospectively analyzed all children aged 2 to 24 months, without known uropathy, who presented with a first episode of febrile UTI between 2009 and 2012 and followed them for 30 months. We then used DCA to estimate the benefit of post-UTI sonography or post-UTI sonography + biological markers of inflammation for detecting the risk of recurrence. A total of 318 children [144 boys (45.3 %) and 174 girls (54.7 %)], with a mean age of 6.9 ± 5.6 months, were identified. Of these, 210 children presented with a significant inflammation [66.2 %; 95 % confidence interval (CI) 61.0-71.4], and 30 (9.4 %; 95 % CI 6.2-12.6) presented with abnormal post-UTI sonographic findings. Eighteen (5.7 %; 95 % CI 3.1-8.2) children presented with recurrent UTI at 30 months. There were significantly more recurrences in those children who presented with abnormal sonographic findings than in those who did not (relative risk 7.68; 95 % CI 3.03-19.46). However, taking into account the effect of false-positives and false negatives, the DCA revealed that for threshold probabilities of >30 %, at which patients/doctors are concerned about unnecessary interventions (whether tests or treatments), neither post-UTI sonography nor post-UTI sonography + biological markers of inflammation have sufficient value to improve care.

  7. Practical color vision tests for air traffic control applicants: en route center and terminal facilities.

    PubMed

    Mertens, H W; Milburn, N J; Collins, W E

    2000-12-01

    Two practical color vision tests were developed and validated for use in screening Air Traffic Control Specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulation of color-coded materials from the most demanding, safety-critical color task performed in each type of facility. The tests were evaluated using 106 subjects with normal color vision and 85 with color vision deficiency. The en route center test, named the Flight Progress Strips Test (FPST), required the identification of critical red/black coding in computer printing and handwriting on flight progress strips. The terminal option test, named the Aviation Lights Test (ALT), simulated red/green/white aircraft lights that must be identified in night ATC tower operations. Color-coding is a non-redundant source of safety-critical information in both tasks. The FPST was validated by direct comparison of responses to strip reproductions with responses to the original flight progress strips and a set of strips selected independently. Validity was high; Kappa = 0.91 with original strips as the validation criterion and 0.86 with different strips. The light point stimuli of the ALT were validated physically with a spectroradiometer. The reliabilities of the FPST and ALT were estimated with Chronbach's alpha as 0.93 and 0.98, respectively. The high job-relevance, validity, and reliability of these tests increases the effectiveness and fairness of ATCS color vision testing.

  8. Integrating musculoskeletal sonography into rehabilitation: Therapists’ experiences with training and implementation

    PubMed Central

    Gray, Julie McLaughlin; Frank, Gelya; Roll, Shawn C.

    2018-01-01

    Musculoskeletal sonography is rapidly extending beyond radiology; however, best practices for successful integration into new practice contexts are unknown. This study explored non-physician experiences with the processes of training and integration of musculoskeletal sonography into rehabilitation. Qualitative data were captured through multiple sources and iterative thematic analysis was used to describe two occupational therapists’ experiences. The dominant emerging theme was competency, in three domains: technical, procedural and analytical. Additionally, three practice considerations were illuminated: (1) understanding imaging within the dynamics of rehabilitation, (2) navigating nuances of interprofessional care, and (3) implications for post-professional training. Findings indicate that sonography training for rehabilitation providers requires multi-level competency development and consideration of practice complexities. These data lay a foundation on which to explore and develop best practices for incorporating sonographic imaging into the clinic as a means for engaging clients as active participants in the rehabilitation process to improve health and rehabilitation outcomes. PMID:28830315

  9. Exploring Occupational Therapists’ Perceptions of the Usefulness of Musculoskeletal Sonography in Upper-Extremity Rehabilitation

    PubMed Central

    McLaughlin Gray, Julie; Frank, Gelya; Wolkoff, Monique

    2015-01-01

    OBJECTIVE. To identify the potential utility of musculoskeletal sonographic imaging in upper-extremity rehabilitation. METHOD. Two occupational therapists in an outpatient hand rehabilitation clinic were recruited by convenience, were trained in the use of sonography, and implemented sonographic imaging in their clinical practice. Qualitative data were obtained during and after the implementation period by means of questionnaires and interviews. Data collection, analysis, and interpretation were completed in an iterative process that culminated in a thematic analysis of the therapists’ perceptions. RESULTS. The data indicate four potential areas of utility for musculoskeletal sonography in upper-extremity rehabilitation: (1) mastering anatomy and pathology, (2) augmenting clinical reasoning, (3) supplementing intervention, and (4) building evidence. CONCLUSION. Numerous potential uses were identified that would benefit both therapist and client. Further exploration of complexities and efficacy for increasing patient outcomes is recommended to determine best practices for the use of musculoskeletal sonography in upper-extremity rehabilitation. PMID:26114469

  10. Three-dimensional color Doppler imaging of the carotid artery

    NASA Astrophysics Data System (ADS)

    Picot, Paul A.; Rickey, Daniel W.; Mitchell, Ross; Rankin, Richard N.; Fenster, Aaron

    1991-05-01

    Stroke is the third leading cause of death in the United States. It is caused by ischemic injury to the brain, usually resulting from emboli from atherosclerotic plaques. The carotid bifurcation in humans is prone to atherosclerotic disease and is a site where emboli may originate. Currently, carotid stenoses are evaluated by non-invasive duplex Doppler ultrasound, with preoperative verification by intra-arterial angiography. We have developed a system that uses a color Doppler ultrasound imaging system to acquire in-vivo 3-D color Doppler images of the human carotid artery, with the aim of increasing the diagnostic accuracy of ultrasound and decreasing the use of angiography for verification. A clinical TL Ultramark 9 color Doppler ultrasound system was modified by mounting the hand-held ultrasound scan head on a motor-driven translation stage. The stage allows planar ultrasound images to be acquired over 45 mm along the neck between the clavicle and the mandible. A 3- D image is acquired by digitizing, in synchrony with the cardiac cycle, successive color ultrasound video images as the scan head is stepped along the neck. A complete volume set of 64 frames, comprising some 15 megabytes of data, requires approximately 2 minutes to acquire. The volume image is reformatted and displayed on a Sun 4/360 workstation equipped with a TAAC-1 graphics accelerator. The 3-D image may be manipulated in real time to yield the best view of blood flow in the bifurcation.

  11. Color-coded prefilled medication syringes decrease time to delivery and dosing errors in simulated prehospital pediatric resuscitations: A randomized crossover trial☆, ☆

    PubMed Central

    Stevens, Allen D.; Hernandez, Caleb; Jones, Seth; Moreira, Maria E.; Blumen, Jason R.; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S.

    2016-01-01

    Background Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. Methods We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded-syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Results Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28–39) seconds and 42 (95% CI: 36–51) seconds, respectively (difference = 9 [95% CI: 4–14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference = 39%, 95% CI: 13–61%). Conclusions A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. PMID:26247145

  12. Color-coded prefilled medication syringes decrease time to delivery and dosing errors in simulated prehospital pediatric resuscitations: A randomized crossover trial.

    PubMed

    Stevens, Allen D; Hernandez, Caleb; Jones, Seth; Moreira, Maria E; Blumen, Jason R; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S

    2015-11-01

    Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28-39) seconds and 42 (95% CI: 36-51) seconds, respectively (difference=9 [95% CI: 4-14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference=39%, 95% CI: 13-61%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Clinical utilization of musculoskeletal sonography involving non-physician rehabilitation providers: A scoping review

    PubMed Central

    Roll, Shawn C.; Asai, Christina; Tsai, Julieann

    2015-01-01

    Background Musculoskeletal sonography use in point-of-care physical medicine and rehabilitation is rapidly expanding, not only by physiatrists, but also by non-physician rehabilitation providers. Aim To evaluate the current range, extent and nature of literature and to identify emerging areas of evidence for the use of musculoskeletal sonography involving non-physician rehabilitation providers to guide research and clinical practice. Design Scoping Review Setting Inpatient, Outpatient, Other Population Musculoskeletal conditions Methods Five databases were searched and 578 unique abstracts were identified and screened for eligibility. Three raters independently read 68 full texts and 36 articles that reported on applied uses of sonography by non-physician rehabilitation providers were included. Results Eighteen studies described direct clinical use, primarily for outcomes measurement (n=12) or as a biofeedback intervention (n=10). Twelve laboratory studies were included that related morphology to patient reports or validated clinical interventions. Six additional studies, although not involving non-physician providers, were included as they presented potential valuable uses that were not noted in the other included studies, such as monitoring bone healing, tendon repair, and evaluation of idiopathic symptom reports or non-specific primary diagnoses. Conclusion This review indicates that non-physician rehabilitation providers use sonography for outcomes measurement and biofeedback interventions. Research is needed to evaluate effects of these uses on patient outcomes and to explore additional potential uses for clinical reasoning, treatment planning, and monitoring of tissue healing related to intervention. Clinical Rehabilitation Impact Implementation of musculoskeletal sonography by non-physician rehabilitation providers has the potential to be a critically advantageous addition to improve care. PMID:26201705

  14. Congenital portosystemic shunts: prenatal manifestations with postnatal confirmation and follow-up.

    PubMed

    Han, Byoung Hee; Park, Sung Bin; Song, Mi Jin; Lee, Kyung Sang; Lee, Young-Ho; Ko, Sun Young; Lee, Yeon Kyung

    2013-01-01

    The purpose of this study was to evaluate prenatal sonographic findings that could be helpful for diagnosis of congenital intrahepatic portosystemic venous shunts and the follow-up results. Six neonates with congenital shunts between the portal vein and hepatic vein were enrolled in this study. Prenatal sonography was performed in 5 cases. We categorized the cases according to a previously published classification of intrahepatic portosystemic venous shunts and retrospectively reviewed the prenatal and postnatal sonographic examinations to identify findings that might be helpful for diagnosing shunts prenatally. Follow-up sonographic examinations were done until closure of the shunts. Clinical features were also determined. According to the original reports, intrahepatic portosystemic venous shunts were diagnosed by prenatal sonography in 2 of 5 cases. In the remaining 3 cases, there were suggestive abnormal findings on retrospective review, including an abnormal intrahepatic tubular structure, a prominent hepatic vein, and congestive heart failure. Postnatal sonography showed type 2 shunts in all 6 cases. In 1 case, there were 2 type 2 lesions between two branches of the left portal vein and the middle and left hepatic veins. On follow-up sonography, 5 of the 6 congenital shunts had spontaneously closed by 11 months of age. One case was treated with coil embolization during the neonatal period. Intrauterine growth restriction was the most commonly clinical feature prenatally. Findings such as an abnormal tubular structure, a prominent hepatic vein, and congestive heart failure can be important clues for identifying congenital intrahepatic portosystemic venous shunts on prenatal sonography. The use of prenatal and postnatal sonography is feasible for detection and evaluation of these shunts.

  15. Color Code: Using Hair Color to Make a Clear Connection between Genotype and Phenotype

    ERIC Educational Resources Information Center

    Bonner, J. Jose

    2011-01-01

    Students may wonder why they look the way they do. The answer lies in genetics, the branch of biology that deals with heredity and the variation of inherited traits. However, understanding how an organism's genetic code (i.e., genotype) affects its characteristics (i.e., phenotype) is more than a matter of idle curiosity: It's essential for…

  16. Effect of task demands on dual coding of pictorial stimuli.

    PubMed

    Babbitt, B C

    1982-01-01

    Recent studies have suggested that verbal labeling of a picture does not occur automatically. Although several experiments using paired-associate tasks produced little evidence indicating the use of a verbal code with picture stimuli, the tasks were probably not sensitive to whether the codes were activated initially. It is possible that verbal labels were activated at input, but not used later in performing the tasks. The present experiment used a color-naming interference task in order to assess, with a more sensitive measure, the amount of verbal coding occurring in response to word or picture input. Subjects named the color of ink in which words were printed following either word or picture input. If verbal labeling of the input occurs, then latency of color naming should increase when the input item and color-naming word are related. The results provided substantial evidence of such verbal activation when the input items were words. However, the presence of verbal activation with picture input was a function of task demands. Activation occurred when a recall memory test was used, but not when a recognition memory test was used. The results support the conclusion that name information (labels) need not be activated during presentation of visual stimuli.

  17. [Ultrasound and color Doppler applications in nephrology. The normal kidney: anatomy, vessels and congenital anomalies].

    PubMed

    Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina

    2012-01-01

    Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.

  18. [Spectral-Doppler-Sonography - Step by Step].

    PubMed

    Bönhof, Leoni; Steffgen, Ludwig; Bönhof, Jörg

    2018-06-07

    Step by step explanation and detailed overview of the correct approach to spectral-Doppler-sonography, including several practical examples. The article provides comprehensive explanations of the appropriate settings in different situations. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Effect of color coding and subtraction on the accuracy of contrast echocardiography

    NASA Technical Reports Server (NTRS)

    Pasquet, A.; Greenberg, N.; Brunken, R.; Thomas, J. D.; Marwick, T. H.

    1999-01-01

    BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

  20. Renal pelvis urothelial carcinoma of the upper moiety in complete right renal duplex: a case report.

    PubMed

    Zhang, Yiran; Yu, Quanfeng; Zhang, Zhihong; Liu, Ranlu; Xu, Yong

    2015-01-01

    Urothelial carcinoma (UC) originated from renal pelvis is the common tumor of the urinary system, however, neoplasia of the renal pelvis in duplex kidneys is extremely rare, especially in the complete renal and ureteral duplex cases. We present the first case of renal pelvis UC of the upper moiety in a complete right renal duplex. This male patient has bilateral complete renal and ureteral duplex. To the best of our knowledge, this is the first reported case of renal pelvis UC in a complete renal duplex system. After this experience we feel that the diagnosis of renal pelvis UC in duplex kidneys is not so easy, and once the diagnosis is determined, the whole renal duplex units and bladder cuff or ectopic orifice should be excised radically.

  1. Three-dimensional quick response code based on inkjet printing of upconversion fluorescent nanoparticles for drug anti-counterfeiting.

    PubMed

    You, Minli; Lin, Min; Wang, Shurui; Wang, Xuemin; Zhang, Ge; Hong, Yuan; Dong, Yuqing; Jin, Guorui; Xu, Feng

    2016-05-21

    Medicine counterfeiting is a serious issue worldwide, involving potentially devastating health repercussions. Advanced anti-counterfeit technology for drugs has therefore aroused intensive interest. However, existing anti-counterfeit technologies are associated with drawbacks such as the high cost, complex fabrication process, sophisticated operation and incapability in authenticating drug ingredients. In this contribution, we developed a smart phone recognition based upconversion fluorescent three-dimensional (3D) quick response (QR) code for tracking and anti-counterfeiting of drugs. We firstly formulated three colored inks incorporating upconversion nanoparticles with RGB (i.e., red, green and blue) emission colors. Using a modified inkjet printer, we printed a series of colors by precisely regulating the overlap of these three inks. Meanwhile, we developed a multilayer printing and splitting technology, which significantly increases the information storage capacity per unit area. As an example, we directly printed the upconversion fluorescent 3D QR code on the surface of drug capsules. The 3D QR code consisted of three different color layers with each layer encoded by information of different aspects of the drug. A smart phone APP was designed to decode the multicolor 3D QR code, providing the authenticity and related information of drugs. The developed technology possesses merits in terms of low cost, ease of operation, high throughput and high information capacity, thus holds great potential for drug anti-counterfeiting.

  2. REX3DV1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holm, Elizabeth A.

    2002-03-28

    This code is a FORTRAN code for three-dimensional Monte Carol Potts Model (MCPM) Recrystallization and grain growth. A continuum grain structure is mapped onto a three-dimensional lattice. The mapping procedure is analogous to color bitmapping the grain structure; grains are clusters of pixels (sites) of the same color (spin). The total system energy is given by the Pott Hamiltonian and the kinetics of grain growth are determined through a Monte Carlo technique with a nonconserved order parameter (Glauber dynamics). The code can be compiled and run on UNIX/Linux platforms.

  3. Sequence-Selective Formation of Synthetic H-Bonded Duplexes

    PubMed Central

    2017-01-01

    Oligomers equipped with a sequence of phenol and pyridine N-oxide groups form duplexes via H-bonding interactions between these recognition units. Reductive amination chemistry was used to synthesize all possible 3-mer sequences: AAA, AAD, ADA, DAA, ADD, DAD, DDA, and DDD. Pairwise interactions between the oligomers were investigated using NMR titration and dilution experiments in toluene. The measured association constants vary by 3 orders of magnitude (102 to 105 M–1). Antiparallel sequence-complementary oligomers generally form more stable complexes than mismatched duplexes. Mismatched duplexes that have an excess of H-bond donors are stabilized by the interaction of two phenol donors with one pyridine N-oxide acceptor. Oligomers that have a H-bond donor and acceptor on the ends of the chain can fold to form intramolecular H-bonds in the free state. The 1,3-folding equilibrium competes with duplex formation and lowers the stability of duplexes involving these sequences. As a result, some of the mismatch duplexes are more stable than some of the sequence-complementary duplexes. However, the most stable mismatch duplexes contain DDD and compete with the most stable sequence-complementary duplex, AAA·DDD, so in mixtures that contain all eight sequences, sequence-complementary duplexes dominate. Even higher fidelity sequence selectivity can be achieved if alternating donor–acceptor sequences are avoided. PMID:28857551

  4. Slipping rib syndrome: a place for sonography in the diagnosis of a frequently overlooked cause of abdominal or low thoracic pain.

    PubMed

    Meuwly, Jean-Yves; Wicky, Stephan; Schnyder, Pierre; Lepori, Domenico

    2002-03-01

    To describe the sonographic appearance of a poorly recognized cause of low thoracic or upper abdominal pain. Three sonographic descriptions of slipping rib syndrome are presented. The 3 patients had abnormal mobility of a cartilaginous rib, which could slip over an adjacent rib during abdominal muscle contraction. Slipping rib syndrome should be considered in patients with histories of upper abdominal or low thoracic pain of unknown origin. We suggest that high-resolution sonography of the costal margin should be added to abdominal sonography in cases of nonspecific abdominal pain.

  5. A transcranial Doppler sonography study of shoot/don't-shoot responding.

    PubMed

    Schultz, Natasha B; Matthews, Gerald; Warm, Joel S; Washburn, David A

    2009-08-01

    The purpose of this study was to examine the relationship between changes in cerebral blood-flow velocity and performance on a speeded shoot/don't-shoot task. Brain activity as indicated by cerebral blood-flow velocity (hemovelocity) was recorded using the transcranial Doppler ultrasonography. A shoot/don't-shoot decision-making task presented participants with threat/nonthreat stimuli in the form of bull's-eye images of various colors. Participants were required to shoot threat targets using a laser-modified handgun. Results support a vigilance decrement in both the performance measures and hemovelocity. Performance, as measured by reaction time, number of hits, and marksmanship, decreased across the length of the vigil. Hemovelocity slowed across the left and right hemispheres as the task progressed, and hemovelocity was slower in the right hemisphere than in the left hemisphere.

  6. Ulnar nerve sonography in leprosy neuropathy.

    PubMed

    Wang, Zhu; Liu, Da-Yue; Lei, Yang-Yang; Yang, Zheng; Wang, Wei

    2016-01-01

    A 23-year-old woman presented with a half-year history of right forearm sensory and motor dysfunction. Ultrasound imaging revealed definite thickening of the right ulnar nerve trunk and inner epineurium, along with heterogeneous hypoechogenicity and unclear nerve fiber bundle. Color Doppler exhibited a rich blood supply, which was clearly different from the normal ulnar nerve presentation with a scarce blood supply. The patient subsequently underwent needle aspiration of the right ulnar nerve, and histopathological examination confirmed that granulomatous nodules had formed with a large number of infiltrating lymphocytes and a plurality of epithelioid cells in the fibrous connective tissues, with visible atypical foam cells and proliferous vascularization, consistent with leprosy. Our report will familiarize readers with the characteristic sonographic features of the ulnar nerve in leprosy, particularly because of the decreasing incidence of leprosy in recent years.

  7. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study

    PubMed Central

    Zavoreo, Iris; Vučićević, Vanja; Zadravec, Dijana; Bašić, Vanja; Kes; Ciliga, Dubravka; Gabrić, Dragana

    2017-01-01

    Objective Burning mouth syndrome (BMS) is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. Also, the results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. Methods By use of transcranial sonography of the brain parenchyma, substantia nigra, midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years) and 20 controls with chronic pain in the lumbosacral region (61.5±15). Statistical analysis was performed by use of Student t test with significance set at p<0.05. Results The results of this study have shown hypoechogenicity of the substantia nigra and midbrain raphe as well as hyperechogenicity of the brain nucleus in BMS patients (p<0,05) as compared to controls. Conclusions Altered transcranial sonography findings of the brain parenchyma, midbrain raphe and brain nucleus in patients with burning mouth syndrome might reflect central disturbances within this syndrome. Key words Burning Mouth Syndrome; Transcranial Sonography; substantia nigra; Midbrain Raphe Nuclei; Red Nucleus PMID:28740270

  8. Sonography of the musculoskeletal system in dogs and cats.

    PubMed

    Kramer, M; Gerwing, M; Hach, V; Schimke, E

    1997-01-01

    Sonography of the musculoskeletal system in dogs and cats was undertaken to evaluate the application of this imaging procedure in orthopedics. In most of the patients a 7.5 MHz linear transducer was used because of its flat application surface and its resolving power. The evaluation of bone by sonography is limited, but sonography can provide addition information regarding the bone surface and surrounding soft tissue. Ultrasound is valuable for assessing joint disease. Joint effusion, thickening of the joint capsule and cartilage defects can be identified sonographically. It is also possible to detect bone destruction. Instabilities are often identified with the help of a dynamic examination. Soft tissue abnormalities of the musculoskeletal system lend themselves to sonographic evaluation. Partial or complete muscles or tendon tears are able to be differentiated and the healing process can be monitored. Most of the diseases that are in the area of the biceps or the achilles tendon, such as dislocation of the tendon, old injuries with scarification, free dissecates in the tendonsheath, tendinitis and/or tendosynovitis can be differentiated by sonography. In addition, with clinical and laboratory findings, it is often possible to make a correct diagnosis with ultrasound in patients with abscesses, foreign bodies, hematomas, soft tissue tumors and lipomas.

  9. Fault-tolerance in Two-dimensional Topological Systems

    NASA Astrophysics Data System (ADS)

    Anderson, Jonas T.

    This thesis is a collection of ideas with the general goal of building, at least in the abstract, a local fault-tolerant quantum computer. The connection between quantum information and topology has proven to be an active area of research in several fields. The introduction of the toric code by Alexei Kitaev demonstrated the usefulness of topology for quantum memory and quantum computation. Many quantum codes used for quantum memory are modeled by spin systems on a lattice, with operators that extract syndrome information placed on vertices or faces of the lattice. It is natural to wonder whether the useful codes in such systems can be classified. This thesis presents work that leverages ideas from topology and graph theory to explore the space of such codes. Homological stabilizer codes are introduced and it is shown that, under a set of reasonable assumptions, any qubit homological stabilizer code is equivalent to either a toric code or a color code. Additionally, the toric code and the color code correspond to distinct classes of graphs. Many systems have been proposed as candidate quantum computers. It is very desirable to design quantum computing architectures with two-dimensional layouts and low complexity in parity-checking circuitry. Kitaev's surface codes provided the first example of codes satisfying this property. They provided a new route to fault tolerance with more modest overheads and thresholds approaching 1%. The recently discovered color codes share many properties with the surface codes, such as the ability to perform syndrome extraction locally in two dimensions. Some families of color codes admit a transversal implementation of the entire Clifford group. This work investigates color codes on the 4.8.8 lattice known as triangular codes. I develop a fault-tolerant error-correction strategy for these codes in which repeated syndrome measurements on this lattice generate a three-dimensional space-time combinatorial structure. I then develop an integer program that analyzes this structure and determines the most likely set of errors consistent with the observed syndrome values. I implement this integer program to find the threshold for depolarizing noise on small versions of these triangular codes. Because the threshold for magic-state distillation is likely to be higher than this value and because logical CNOT gates can be performed by code deformation in a single block instead of between pairs of blocks, the threshold for fault-tolerant quantum memory for these codes is also the threshold for fault-tolerant quantum computation with them. Since the advent of a threshold theorem for quantum computers much has been improved upon. Thresholds have increased, architectures have become more local, and gate sets have been simplified. The overhead for magic-state distillation has been studied, but not nearly to the extent of the aforementioned topics. A method for greatly reducing this overhead, known as reusable magic states, is studied here. While examples of reusable magic states exist for Clifford gates, I give strong reasons to believe they do not exist for non-Clifford gates.

  10. Structure and stability of the consecutive stereoregulated chiral phosphorothioate DNA duplex.

    PubMed

    Kanaori, K; Tamura, Y; Wada, T; Nishi, M; Kanehara, H; Morii, T; Tajima, K; Makino, K

    1999-12-07

    The duplex structures of the stereoregulated phosphorothioate DNAs, [R(p),R(p)]- and [S(p),S(p)]-[d(GC(ps)T(ps)ACG)] (ps, phosphorothioate; PS-DNA), with their complementary RNA have been investigated by combined use of (1)H NMR and restrained molecular dynamics calculation. Compared to those obtained for the unmodified duplex structures (PO-DNA.RNA), the NOE cross-peak intensities are virtually identical for the PS-DNA.RNA hybrid duplexes. The structural analysis on the basis of the NOE restraints reveals that all of the three DNA.RNA duplexes take a A-form conformation and that there is no significant difference in the base stacking for the DNA.RNA hybrid duplexes. On the other hand, the NOE cross-peak intensities of the protons around the central T(ps)A step of the PS-DNA.DNA duplexes are apparently different from those of PO-DNA. DNA. The chemical shifts of H8/6 and H1' at the T(ps)A step are also largely different among PS-DNA.DNAs and PO-DNA.DNA, suggesting that the DNA.DNA structure is readily changed by the introduction of the phosphorothioate groups to the central T(p)A step. The structure calculations indicate that all of these DNA.DNA duplexes are B-form although there exist some small differences in helical parameters between the [R(p),R(p)]- and [S(p),S(p)]PS-DNA.DNA duplexes. The melting temperatures (T(m)) were determined for all of the duplexes by plotting the chemical shift change of isolated peaks as a function of temperature. For the PS-DNA.RNA hybrid duplexes, the [S(p),S(p)] isomer is less stable than the [R(p),R(p)] isomer while this trend is reversed for the PS-DNA.DNA duplexes. Consequently, although the PS-DNA.RNA duplexes take the similar A-form structure, the duplex stability is different between PS-DNA.RNA duplexes. The stability of the DNA.RNA duplexes may not be governed by the A-form structure itself but by some other factors such as the hydration around the phosphorothioate backbone, although the T(m) difference of the DNA.DNA duplexes could be explained by the structural factor.

  11. Guidelines for the Use of Color in ATC Displays

    DOT National Transportation Integrated Search

    1999-06-01

    Color is probably the most effective, compelling, and attractive method available for coding visual information on a display. However, caution must be used in the application of color to displays for air traffic control (ATC), because it is easy to d...

  12. Utilization of NASA Lewis mobile terminals for the Hermes satellite

    NASA Technical Reports Server (NTRS)

    Edelman, E. A.; Fiala, J. L.; Rizzolla, L.

    1977-01-01

    The paper describes the portable earth terminal (PET) and the transportable earth terminal (TET) which enable two-way television and voice communication. Both terminals were developed by NASA and utilize the high power of the Hermes satellite. PET is a bus-type vehicle which has receiving equipment for full duplex color television and which can transmit programs originating in either the on-board PET studio or in nearby buildings. PET has a collapsible 2.4-m diameter parabolic antenna interfacing with a 500-watt 14-GHz wideband TV transmitter and a 12-GHz wideband TV receiver system. TET uses two parabolic reflector antennas, 3 m and 1.2 m in diameter, mounted on a flat trailer towed by a truck. TET can receive and relay color TV signals, and its narrowband transmitter can serve as a return audio link permitting a question-and-answer format. Also described are uplink and downlink performance characteristics, operation procedures, and field demonstrations which enabled personnel at several hospitals to participate in a distant medical conference.

  13. Cognitive aspects of color

    NASA Astrophysics Data System (ADS)

    Derefeldt, Gunilla A. M.; Menu, Jean-Pierre; Swartling, Tiina

    1995-04-01

    This report surveys cognitive aspects of color in terms of behavioral, neuropsychological, and neurophysiological data. Color is usually defined as psychophysical color or as perceived color. Behavioral data on categorical color perception, absolute judgement of colors, color coding, visual search, and visual awareness refer to the more cognitive aspects of color. These are of major importance in visual synthesis and spatial organization, as already shown by the Gestalt psychologists. Neuropsychological and neurophysiological findings provide evidence for an interrelation between cognitive color and spatial organization. Color also enhances planning strategies, as has been shown by studies on color and eye movements. Memory colors and the color- language connections in the brain also belong among the cognitive aspects of color.

  14. The haemodynamic effects of bolus versus slower infusion of intravenous crystalloid in healthy volunteers.

    PubMed

    Ukor, Ida F; Hilton, Andrew K; Bailey, Michael J; Bellomo, Rinaldo

    2017-10-01

    This pilot study aimed to characterise the haemodynamic effect of 1L of IV normal saline (NS) administered as a rapid versus slow infusion on cardiac output (CO), heart rate (HR), systemic blood pressures, and carotid blood flow in six healthy volunteers. Six healthy male volunteers aged 18-65years were randomized to receive 1L NS given over 30min or 120min. On a subsequent study session the alternate fluid regimen was administered. Haemodynamic data was gathered using a non-invasive finger arterial pressure monitor (Nexfin®), echocardiography and carotid duplex sonography. Time to micturition and urine volume was also assessed. Compared to baseline, rapid infusion of 1L of saline over 30min produced a fall in Nexfin®-measured CO by 0.62L/min (p<0.001), whereas there was a marginal but significant increase during infusion of 1L NS over 120min of 0.02L/min (p<0.001). This effect was mirrored by changes in HR and blood pressure (BP) (p<0.001). There were no significant changes in carotid blood flow, time to micturition, or urine volume produced. Slower infusion of 1L NS in healthy male volunteers produced a greater increase in CO, HR and BP than rapid infusion. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

    PubMed

    Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan

    2006-04-01

    To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

  16. High Residual Collagen-Induced Platelet Reactivity Predicts Development of Restenosis in the Superficial Femoral Artery After Percutaneous Transluminal Angioplasty in Claudicant Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary, Thomas, E-mail: thomas.gary@medunigraz.at; Prüller, Florian, E-mail: florian.prueller@klinikum-graz.at; Raggam, Reinhard, E-mail: reinhard.raggam@klinikum-graz.at

    PurposeAlthough platelet reactivity is routinely inhibited with aspirin after percutaneous angioplasty (PTA) in peripheral arteries, the restenosis rate in the superficial femoral artery (SFA) is high. Interaction of activated platelets and the endothelium in the region of intervention could be one reason for this as collagen in the subendothelium activates platelets.Materials and MethodsA prospective study evaluating on-site platelet reactivity during PTA and its influence on the development of restenosis with a total of 30 patients scheduled for PTA of the SFA. Arterial blood was taken from the PTA site after SFA; platelet function was evaluated with light transmission aggregometry. Aftermore » 3, 6, 12, and 24 months, duplex sonography was performed and the restenosis rate evaluated.ResultsEight out of 30 patients developed a hemodynamically relevant restenosis (>50 % lumen narrowing) in the PTA region during the 24-month follow-up period. High residual collagen-induced platelet reactivity defined as AUC >30 was a significant predictor for the development of restenosis [adjusted odds ratio 11.8 (9.4, 14.2); P = .04].ConclusionsHigh residual collagen-induced platelet reactivity at the interventional site predicts development of restenosis after PTA of the SFA. Platelet function testing may be useful for identifying patients at risk.« less

  17. Multi-shell model of ion-induced nucleic acid condensation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolokh, Igor S.; Drozdetski, Aleksander V.; Pollack, Lois

    2016-04-21

    We present a semi-quantitative model of condensation of short nucleic acid (NA) duplexes in- duced by tri-valent cobalt hexammine (CoHex) ions. The model is based on partitioning of bound counterion distribution around single NA duplex into “external” and “internal” ion binding shells distinguished by the proximity to duplex helical axis. The duplex aggregation free energy is de- composed into attraction and repulsion components represented by simple analytic expressions. The source of the short-range attraction between NA duplexes in the aggregated phase is the in- teraction of CoHex ions in the overlapping regions of the “external” shells with the oppositely chargedmore » duplexes. The attraction depends on CoHex binding affinity to the “external” shell of nearly neutralized duplex and the number of ions in the shell overlapping volume. For a given NA duplex sequence and structure, these parameters are estimated from molecular dynamics simula- tion. The attraction is opposed by the residual repulsion of nearly neutralized duplexes as well as duplex configurational entropy loss upon aggregation. The estimates of the aggregation free energy are consistent with the experimental range of NA duplex condensation propensities, including the unusually poor condensation of RNA structures and subtle sequence effects upon DNA conden- sation. The model predicts that, in contrast to DNA, RNA duplexes may condense into tighter packed aggregates with a higher degree of duplex neutralization. The model also predicts that longer NA fragments will condense easier than shorter ones. The ability of this model to explain experimentally observed trends in NA condensation, lends support to proposed NA condensation picture based on the multivalent “ion binding shells”.« less

  18. Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography.

    PubMed

    Adams, Scott J; Burbridge, Brent E; Badea, Andreea; Langford, Leanne; Vergara, Vincent; Bryce, Rhonda; Bustamante, Luis; Mendez, Ivar M; Babyn, Paul S

    2017-08-01

    The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths (P values < .05). All patients responded that they would be willing to have another telerobotic examination. A telerobotic ultrasound system is feasible for performing abdominal ultrasound examinations at a distant location with minimal training and setup requirements and a moderate learning curve. Telerobotic sonography (robotic telesonography) may open up the possibility of remote ultrasound clinics for communities that lack skilled sonographers and radiologists, thereby improving access to care. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Combined Use of Ultrasound Elastography and B-Mode Sonography for Differentiation of Benign and Malignant Circumscribed Breast Masses.

    PubMed

    Kim, Soo-Yeon; Park, Jeong Seon; Koo, Hye Ryoung

    2015-11-01

    To evaluate the diagnostic performance of combined B-mode sonography and ultrasound elastography for differentiation between benign and malignant breast masses with circumscribed margins. We analyzed 109 pathologically proven circumscribed breast masses. Two radiologists retrospectively reviewed B-mode sonograms and elastograms in consensus. Based on the American College of Radiology Breast Imaging Reporting and Data System, we determined categories of the masses on B-mode sonography. Elastographic scores were assessed by a 3-point scale (negative, 0; equivocal, 1; and positive, 2). When the elastographic score for a lesion was 0 or 2, we downgraded or upgraded the B-mode category, respectively; thus, the reclassified Breast Imaging Reporting and Data System category was defined as the "reclassification category." Mean category values for benign and malignant lesions were compared by a Student t test. The diagnostic performance of B-mode, elastographic, and reclassification assessments was compared by receiver operating characteristic curve analysis. The mean B-mode category (2.5 versus 1.7), elastographic score (1.7 versus 0.8), and reclassification category (3.2 versus 1.6) were significantly higher in malignant than benign lesions (P < .001). The area under the curve for reclassification assessment was significantly higher than that for B-mode sonography (0.916 versus 0.795; P < .05). With a cutoff value between 1 and 2, the specificity was increased from 26.5% to 42.9% after reclassification. For differentiation between benign and malignant circumscribed breast masses, combined use of B-mode sonography and elastography could provide a better diagnostic performance than B-mode sonography alone. © 2015 by the American Institute of Ultrasound in Medicine.

  20. Optimization of Region of Interest Drawing for Quantitative Analysis: Differentiation Between Benign and Malignant Breast Lesions on Contrast-Enhanced Sonography.

    PubMed

    Nakata, Norio; Ohta, Tomoyuki; Nishioka, Makiko; Takeyama, Hiroshi; Toriumi, Yasuo; Kato, Kumiko; Nogi, Hiroko; Kamio, Makiko; Fukuda, Kunihiko

    2015-11-01

    This study was performed to evaluate the diagnostic utility of quantitative analysis of benign and malignant breast lesions using contrast-enhanced sonography. Contrast-enhanced sonography using the perflubutane-based contrast agent Sonazoid (Daiichi Sankyo, Tokyo, Japan) was performed in 94 pathologically proven palpable breast mass lesions, which could be depicted with B-mode sonography. Quantitative analyses using the time-intensity curve on contrast-enhanced sonography were performed in 5 region of interest (ROI) types (manually traced ROI and circular ROIs of 5, 10, 15, and 20 mm in diameter). The peak signal intensity, initial slope, time to peak, positive enhancement integral, and wash-out ratio were investigated in each ROI. There were significant differences between benign and malignant lesions in the time to peak (P < .05), initial slope (P < .001), and positive enhancement integral (P < .05) for the manual ROI. Significant differences were found between benign and malignant lesions in the time to peak (P < .05) for the 5-mm ROI; the time to peak (P < .05) and initial slope (P< .05) for the 10-mm ROI; absolute values of the peak signal intensity (P< .05), time to peak (P< .01), and initial slope (P< .005) for the 15-mm ROI; and the time to peak (P < .05) and initial slope (P < .05) for the 20-mm ROI. There were no statistically significant differences in any wash-out ratio values for the 5 ROI types. Kinetic analysis using contrast-enhanced sonography is useful for differentiation between benign and malignant breast lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  1. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: usefulness of virtual CT sonography with magnetic navigation.

    PubMed

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-03-01

    Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Sonography-guided hydrostatic reduction of ileocolic intussusception in children: analysis of failure and success in consecutive patients presenting timely to the hospital.

    PubMed

    Menke, Jan; Kahl, Fritz

    2015-03-01

    In children with ileocolic intussusception sonography is increasingly being used for diagnosis, whereas fluoroscopy is frequently used for guiding non-invasive reduction. This study assessed the success rate of radiation-free sonography-guided hydrostatic reduction in children with ileocolic intussusception, using novel well-defined success rate indices. All children were evaluated who presented from 2005 to 2013 to the local university hospital with ileocolic intussusception. The patients were treated with sonography-guided hydrostatic reduction unless primary surgery was clinically indicated. The according success rate was determined by indices of Bekdash et al. They represent the ratio of persistently successful non-surgical reductions versus four different denominators, depending on including/excluding cases with primary surgery and including/excluding cases requiring bowel resection/intervention. Fifty-six consecutive patients were included (age, 3 months to 7.8 years). About 80% of the patients presented until 24 h and 20% until 48 h after the onset of symptoms. Seven patients underwent primary surgery, with bowel resection required in three cases. Hydrostatic reduction was attempted in 49 patients, being permanently successful in 41 cases (selective reduction rate 41/49 = 83.7%; crude reduction rate 41/56 = 73.2%). The remaining eight patients underwent secondary surgery, with just two patients not requiring surgical bowel resection/intervention (corrected selective reduction rate 41/43 = 95.3%). The composite reduction rate was 87.2% (successful/feasible reductions, 41/47). Radiation-free sonography-guided hydrostatic reduction has a good success rate in children with ileocolic intussusception. It may be particularly valuable in centers that are already experienced with using sonography for the diagnosis.

  3. Sonographic findings of high-grade and non-high-grade ductal carcinoma in situ of the breast.

    PubMed

    Park, Ji-Sung; Park, Young-Mi; Kim, Eun-Kyung; Kim, Suk-Jung; Han, Sang-Suk; Lee, Sun-Joo; In, Hyun-Sin; Ryu, Ji-Hwa

    2010-12-01

    The purpose of this study was to differentiate between high-grade and non-high-grade ductal carcinoma in situ (DCIS) of the breast on sonography. From October 2003 to August 2009, 76 DCIS lesions in 73 women who underwent sonography and mammography were included in this study. Lesions were confirmed by mastectomy, breast-conserving surgery, or surgical biopsy. Images were analyzed by 2 radiologists with consensus and were correlated with histologic grades. Of the 76 lesions, 44 were classified as high--grade and 32 as non-high-grade DCIS. Fifty-seven lesions (75.0%) were identified on sonography, which revealed a mass in 30 cases, microcalcifications in 20, ductal changes in 4, and architectural distortion in 3. All cases with false-negative findings on sonography (n = 19) showed microcalcifications on mammography. On sonography, masses were more frequently found in non-high-grade (62.5%) than high-grade DCIS (22.7%; P < .01). No significant difference was seen in the sonographic features of masses between high-grade and non-high-grade DCIS. Microcalcifications were more common in high-grade (43.2%) than non-high-grade (3.1%) DCIS (P = .02). Most sonographically visible microcalcifications had associated findings such as ductal changes (n = 11), a mass (n = 7), or a hypoechoic area (n = 5). The detection rate of microcalcifications on sonography was higher in high-grade (62.9%) than non-high-grade DCIS (25.0%; P = .023). Microcalcifications with associated ductal changes (11 of 31 [35.5%]) were the most common sonographic findings in high-grade DCIS. An irregular hypoechoic mass with an indistinct and microlobulated margin (13 of 26 [50.0%]) was the most frequent finding in non-high-grade DCIS.

  4. Duplex Ultrasonography Has Limited Utility in Detection of Postoperative DVT After Primary Total Joint Arthroplasty.

    PubMed

    Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick

    2016-07-01

    Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a DVT which can embolize to the lungs and thus should not preclude further workup when clinical suspicion exists for a pulmonary embolus.

  5. Use of color on airport moving maps and cockpit displays of traffic information (CDTIs)

    DOT National Transportation Integrated Search

    2014-06-01

    Color can be an effective method for coding visual information, making it easier to find and identify symbols on a display (Christ, 1975). However, careful consideration should be given when applying color because excessive or inappropriate use of co...

  6. Single-exposure quantitative phase imaging in color-coded LED microscopy.

    PubMed

    Lee, Wonchan; Jung, Daeseong; Ryu, Suho; Joo, Chulmin

    2017-04-03

    We demonstrate single-shot quantitative phase imaging (QPI) in a platform of color-coded LED microscopy (cLEDscope). The light source in a conventional microscope is replaced by a circular LED pattern that is trisected into subregions with equal area, assigned to red, green, and blue colors. Image acquisition with a color image sensor and subsequent computation based on weak object transfer functions allow for the QPI of a transparent specimen. We also provide a correction method for color-leakage, which may be encountered in implementing our method with consumer-grade LEDs and image sensors. Most commercially available LEDs and image sensors do not provide spectrally isolated emissions and pixel responses, generating significant error in phase estimation in our method. We describe the correction scheme for this color-leakage issue, and demonstrate improved phase measurement accuracy. The computational model and single-exposure QPI capability of our method are presented by showing images of calibrated phase samples and cellular specimens.

  7. Epitaxial Growth of Hetero-Ln-MOF Hierarchical Single Crystals for Domain- and Orientation-Controlled Multicolor Luminescence 3D Coding Capability.

    PubMed

    Pan, Mei; Zhu, Yi-Xuan; Wu, Kai; Chen, Ling; Hou, Ya-Jun; Yin, Shao-Yun; Wang, Hai-Ping; Fan, Ya-Nan; Su, Cheng-Yong

    2017-11-13

    Core-shell or striped heteroatomic lanthanide metal-organic framework hierarchical single crystals were obtained by liquid-phase anisotropic epitaxial growth, maintaining identical periodic organization while simultaneously exhibiting spatially segregated structure. Different types of domain and orientation-controlled multicolor photophysical models are presented, which show either visually distinguishable or visible/near infrared (NIR) emissive colors. This provides a new bottom-up strategy toward the design of hierarchical molecular systems, offering high-throughput and multiplexed luminescence color tunability and readability. The unique capability of combining spectroscopic coding with 3D (three-dimensional) microscale spatial coding is established, providing potential applications in anti-counterfeiting, color barcoding, and other types of integrated and miniaturized optoelectronic materials and devices. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Three-Dimensional Color Code Thresholds via Statistical-Mechanical Mapping

    NASA Astrophysics Data System (ADS)

    Kubica, Aleksander; Beverland, Michael E.; Brandão, Fernando; Preskill, John; Svore, Krysta M.

    2018-05-01

    Three-dimensional (3D) color codes have advantages for fault-tolerant quantum computing, such as protected quantum gates with relatively low overhead and robustness against imperfect measurement of error syndromes. Here we investigate the storage threshold error rates for bit-flip and phase-flip noise in the 3D color code (3DCC) on the body-centered cubic lattice, assuming perfect syndrome measurements. In particular, by exploiting a connection between error correction and statistical mechanics, we estimate the threshold for 1D stringlike and 2D sheetlike logical operators to be p3DCC (1 )≃1.9 % and p3DCC (2 )≃27.6 % . We obtain these results by using parallel tempering Monte Carlo simulations to study the disorder-temperature phase diagrams of two new 3D statistical-mechanical models: the four- and six-body random coupling Ising models.

  9. [Prenatal diagnosis of the Dandy-Walker syndrome using sonography and computed tomography].

    PubMed

    Tölly, E; Ebner, F; Oberbauer, R W

    1984-07-01

    A case of Dandy-Walker-syndrome is presented, comparing the value of sonography and CT in intrauterine diagnosis. Together with a review of the literature of the subject, pathogenesis, morphology and prognosis in regard to the psychomotoric development are discussed.

  10. Students' learning of clinical sonography: use of computer-assisted instruction and practical class.

    PubMed

    Wood, A K; Dadd, M J; Lublin, J R

    1996-08-01

    The application of information technology to teaching radiology will profoundly change the way learning is mediated to students. In this project, the integration of veterinary medical students' knowledge of sonography was promoted by a computer-assisted instruction program and a subsequent practical class. The computer-assisted instruction program emphasized the physical principles of clinical sonography and contained simulations and user-active experiments. In the practical class, the students used an actual sonographic machine for the first time and made images of a tissue-equivalent phantom. Students' responses to questionnaires were analyzed. On completing the overall project, 96% of the students said that they now understood sonographic concepts very or reasonably well, and 98% had become very or moderately interested in clinical sonography. The teaching and learning initiatives enhanced an integrated approach to learning, stimulated student interest and curiosity, improved understanding of sonographic principles, and contributed to an increased confidence and skill in using sonographic equipment.

  11. Sonographic diagnosis and successful nonoperative management of sealed perforated duodenal ulcer.

    PubMed

    Fujii, Yasutomo; Asato, Mitsunobu; Taniguchi, Nobuyuki; Shigeta, Kouichiro; Omoto, Kiyoka; Itoh, Kouichi; Suzukawa, Masayuki

    2003-01-01

    We encountered a case of sealed perforated duodenal ulcer in a 75-year-old woman with rheumatoid arthritis and chronic renal failure. Abdominal sonography showed a bright linear echo within the thickened anterior wall of the duodenal bulb and the presence of free air at the anterior surface of the liver. We found no signs of direct communication between the duodenal lumen and the peritoneal cavity or any free fluid. On follow-up sonography performed every 2 days during the first week of the patient's hospitalization, no free fluid was found in the abdomen. The use of sonography to diagnose this patient's sealed perforated duodenal ulcer and to monitor the ulcer for the appearance of free fluid allowed us to provide successful nonsurgical management to this patient. We believe that the use of abdominal sonography in all patients suspected of having a perforated duodenal ulcer may help increase the diagnostic accuracy of this modality and may reduce the need for surgery in such patients. Copyright 2002 Wiley Periodicals, Inc.

  12. Small part ultrasound in childhood and adolescence.

    PubMed

    Wunsch, R; von Rohden, L; Cleaveland, R; Aumann, V

    2014-09-01

    Small-part sonography refers to the display of small, near-surface structures using high-frequency linear array transducers. Traditional applications for small part ultrasound imaging include visualization and differential diagnostic evaluation in unclear superficial bodily structures with solid, liquid and mixed texture, as well as similar structures in nearly superficial organs such as the thyroid glands and the testes. Furthermore indications in the head and neck regions are the assessment of the outer CSF spaces in infants, the sonography of the orbit, the sonography of the walls of the large neck vessels, the visualization of superficially situated lymph nodes and neoplasms. Clinical evidence concludes that sonography, having of all imaging modalities the highest spatial resolution in the millimeter- and micrometer range (100-1000μm), can be considered the best suited technique for examining superficial pathological formations and near-surface organs. In addition, it delivers important information about characteristic, often pathognomonic tissue architecture in pathological processes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    PubMed

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  14. Force-Induced Rupture of a DNA Duplex: From Fundamentals to Force Sensors.

    PubMed

    Mosayebi, Majid; Louis, Ard A; Doye, Jonathan P K; Ouldridge, Thomas E

    2015-12-22

    The rupture of double-stranded DNA under stress is a key process in biophysics and nanotechnology. In this article, we consider the shear-induced rupture of short DNA duplexes, a system that has been given new importance by recently designed force sensors and nanotechnological devices. We argue that rupture must be understood as an activated process, where the duplex state is metastable and the strands will separate in a finite time that depends on the duplex length and the force applied. Thus, the critical shearing force required to rupture a duplex depends strongly on the time scale of observation. We use simple models of DNA to show that this approach naturally captures the observed dependence of the force required to rupture a duplex within a given time on duplex length. In particular, this critical force is zero for the shortest duplexes, before rising sharply and then plateauing in the long length limit. The prevailing approach, based on identifying when the presence of each additional base pair within the duplex is thermodynamically unfavorable rather than allowing for metastability, does not predict a time-scale-dependent critical force and does not naturally incorporate a critical force of zero for the shortest duplexes. We demonstrate that our findings have important consequences for the behavior of a new force-sensing nanodevice, which operates in a mixed mode that interpolates between shearing and unzipping. At a fixed time scale and duplex length, the critical force exhibits a sigmoidal dependence on the fraction of the duplex that is subject to shearing.

  15. Zoster duplex: a clinical report and etiologic analysis.

    PubMed

    Zhang, Feng; Zhou, Jin

    2015-01-01

    Herpes zoster (HZ) duplex is a rare disease presentation. The mechanisms of varicella zoster virus (VZV) reactivation in multiple dermal regions are unknown. To present a HZ duplex case occurring in an immunocompetent woman and to analyze the possible underlying causes of HZ duplex. We present a HZ duplex case in an immunocompetent woman and analyzed the possible contributing factors in 36 HZ duplex cases. Continuously distributed variables were categorized by numbers and percentages. In our study, 24 cases (66.7%) were from Asia, 16 cases (44.4%) were in individuals ≥ 50 years of age, and 17 cases (47.2%) occurred in immunocompromised patients. Of the 36 cases, 23 involved women (63.9%) and 13 involved men. Eighteen patients suffering from HZ duplex, 13 of which were women (72.2%), did not suffer from any chronic systemic disease or have a long history of taking drugs. HZ duplex is a rare event that can occur in both immunocompetent and immunosuppressed individuals. HZ duplex might be associated with the Asia region, advanced age, immunosuppression, and being female.

  16. A Dual-Specific Targeting Approach Based on the Simultaneous Recognition of Duplex and Quadruplex Motifs.

    PubMed

    Nguyen, Thi Quynh Ngoc; Lim, Kah Wai; Phan, Anh Tuân

    2017-09-20

    Small-molecule ligands targeting nucleic acids have been explored as potential therapeutic agents. Duplex groove-binding ligands have been shown to recognize DNA in a sequence-specific manner. On the other hand, quadruplex-binding ligands exhibit high selectivity between quadruplex and duplex, but show limited discrimination between different quadruplex structures. Here we propose a dual-specific approach through the simultaneous application of duplex- and quadruplex-binders. We demonstrated that a quadruplex-specific ligand and a duplex-specific ligand can simultaneously interact at two separate binding sites of a quadruplex-duplex hybrid harbouring both quadruplex and duplex structural elements. Such a dual-specific targeting strategy would combine the sequence specificity of duplex-binders and the strong binding affinity of quadruplex-binders, potentially allowing the specific targeting of unique quadruplex structures. Future research can be directed towards the development of conjugated compounds targeting specific genomic quadruplex-duplex sites, for which the linker would be highly context-dependent in terms of length and flexibility, as well as the attachment points onto both ligands.

  17. Distributed polar-coded OFDM based on Plotkin's construction for half duplex wireless communication

    NASA Astrophysics Data System (ADS)

    Umar, Rahim; Yang, Fengfan; Mughal, Shoaib; Xu, HongJun

    2018-07-01

    A Plotkin-based polar-coded orthogonal frequency division multiplexing (P-PC-OFDM) scheme is proposed and its bit error rate (BER) performance over additive white gaussian noise (AWGN), frequency selective Rayleigh, Rician and Nakagami-m fading channels has been evaluated. The considered Plotkin's construction possesses a parallel split in its structure, which motivated us to extend the proposed P-PC-OFDM scheme in a coded cooperative scenario. As the relay's effective collaboration has always been pivotal in the design of cooperative communication therefore, an efficient selection criterion for choosing the information bits has been inculcated at the relay node. To assess the BER performance of the proposed cooperative scheme, we have also upgraded conventional polar-coded cooperative scheme in the context of OFDM as an appropriate bench marker. The Monte Carlo simulated results revealed that the proposed Plotkin-based polar-coded cooperative OFDM scheme convincingly outperforms the conventional polar-coded cooperative OFDM scheme by 0.5 0.6 dBs over AWGN channel. This prominent gain in BER performance is made possible due to the bit-selection criteria and the joint successive cancellation decoding adopted at the relay and the destination nodes, respectively. Furthermore, the proposed coded cooperative schemes outperform their corresponding non-cooperative schemes by a gain of 1 dB under an identical condition.

  18. An evaluation of the effect of JPEG, JPEG2000, and H.264/AVC on CQR codes decoding process

    NASA Astrophysics Data System (ADS)

    Vizcarra Melgar, Max E.; Farias, Mylène C. Q.; Zaghetto, Alexandre

    2015-02-01

    This paper presents a binarymatrix code based on QR Code (Quick Response Code), denoted as CQR Code (Colored Quick Response Code), and evaluates the effect of JPEG, JPEG2000 and H.264/AVC compression on the decoding process. The proposed CQR Code has three additional colors (red, green and blue), what enables twice as much storage capacity when compared to the traditional black and white QR Code. Using the Reed-Solomon error-correcting code, the CQR Code model has a theoretical correction capability of 38.41%. The goal of this paper is to evaluate the effect that degradations inserted by common image compression algorithms have on the decoding process. Results show that a successful decoding process can be achieved for compression rates up to 0.3877 bits/pixel, 0.1093 bits/pixel and 0.3808 bits/pixel for JPEG, JPEG2000 and H.264/AVC formats, respectively. The algorithm that presents the best performance is the H.264/AVC, followed by the JPEG2000, and JPEG.

  19. Higher-Order Thinking and Metacognition in the First-Year Core-Education Classroom: A Case Study in the Use of Color-Coded Drafts

    ERIC Educational Resources Information Center

    Murray, Jeffrey W.

    2014-01-01

    This article seeks to provide some modest insights into the pedagogy of higher-order thinking and metacognition and to share the use of color-coded drafts as a best practice in service of both higher-order thinking and metacognition. This article will begin with a brief theoretical exploration of thinking and of thinking about thinking--the latter…

  20. Action Research of a Color-Coded, Onset-Rime Decoding Intervention: Examining the Effects with First Grade Students Identified as at Risk

    ERIC Educational Resources Information Center

    Wall, Candace A.; Rafferty, Lisa A.; Camizzi, Mariya A.; Max, Caroline A.; Van Blargan, David M.

    2016-01-01

    Many students who struggle to obtain the alphabetic principle are at risk for being identified as having a reading disability and would benefit from additional explicit phonics instruction as a remedial measure. In this action research case study, the research team conducted two experiments to investigate the effects of a color-coded, onset-rime,…

  1. Genetic Recombination Between Stromal and Cancer Cells Results in Highly Malignant Cells Identified by Color-Coded Imaging in a Mouse Lymphoma Model.

    PubMed

    Nakamura, Miki; Suetsugu, Atsushi; Hasegawa, Kousuke; Matsumoto, Takuro; Aoki, Hitomi; Kunisada, Takahiro; Shimizu, Masahito; Saji, Shigetoyo; Moriwaki, Hisataka; Hoffman, Robert M

    2017-12-01

    The tumor microenvironment (TME) promotes tumor growth and metastasis. We previously established the color-coded EL4 lymphoma TME model with red fluorescent protein (RFP) expressing EL4 implanted in transgenic C57BL/6 green fluorescent protein (GFP) mice. Color-coded imaging of the lymphoma TME suggested an important role of stromal cells in lymphoma progression and metastasis. In the present study, we used color-coded imaging of RFP-lymphoma cells and GFP stromal cells to identify yellow-fluorescent genetically recombinant cells appearing only during metastasis. The EL4-RFP lymphoma cells were injected subcutaneously in C57BL/6-GFP transgenic mice and formed subcutaneous tumors 14 days after cell transplantation. The subcutaneous tumors were harvested and transplanted to the abdominal cavity of nude mice. Metastases to the liver, perigastric lymph node, ascites, bone marrow, and primary tumor were imaged. In addition to EL4-RFP cells and GFP-host cells, genetically recombinant yellow-fluorescent cells, were observed only in the ascites and bone marrow. These results indicate genetic exchange between the stromal and cancer cells. Possible mechanisms of genetic exchange are discussed as well as its ramifications for metastasis. J. Cell. Biochem. 118: 4216-4221, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. A Study of the Effect of Color in Memory Retention When Used in Presentation Software.

    ERIC Educational Resources Information Center

    McConnohie, Bruce Vernon

    A study of the effects of color as used in presentation software on short-range (immediately following treatment) and long-range (one hour following treatment) memory retention was conducted. Previous studies have concentrated on color as cueing or coding mechanisms primarily in print media and have not explored the effect of individual colors as…

  3. Mapping the Color Space of Saccadic Selectivity in Visual Search

    ERIC Educational Resources Information Center

    Xu, Yun; Higgins, Emily C.; Xiao, Mei; Pomplun, Marc

    2007-01-01

    Color coding is used to guide attention in computer displays for such critical tasks as baggage screening or air traffic control. It has been shown that a display object attracts more attention if its color is more similar to the color for which one is searching. However, what does "similar" precisely mean? Can we predict the amount of attention…

  4. Investigation of varying gray scale levels for remote manipulation

    NASA Technical Reports Server (NTRS)

    Bierschwale, John M.; Stuart, Mark A.; Sampaio, Carlos E.

    1991-01-01

    A study was conducted to investigate the effects of variant monitor gray scale levels and workplace illumination levels on operators' ability to discriminate between different colors on a monochrome monitor. It was determined that 8-gray scale viewing resulted in significantly worse discrimination performance compared to 16- and 32-gray scale viewing and that there was only a negligible difference found between 16 and 32 shades of gray. Therefore, it is recommended that monitors used while performing remote manipulation tasks have 16 or above shades of gray since this evaluation has found levels lower than this to be unacceptable for color discrimination task. There was no significant performance difference found between a high and a low workplace illumination condition. Further analysis was conducted to determine which specific combinations of colors can be used in conjunction with each other to ensure errorfree color coding/brightness discrimination performance while viewing a monochrome monitor. It was found that 92 three-color combination and 9 four-color combinations could be used with 100 percent accuracy. The results can help to determine which gray scale levels should be provided on monochrome monitors as well as which colors to use to ensure the maximal performance of remotely-viewed color discrimination/coding tasks.

  5. Structural polymorphism exhibited by a quasipalindrome present in the locus control region (LCR) of the human beta-globin gene cluster.

    PubMed

    Kaushik, Mahima; Kukreti, Shrikant

    2006-01-01

    Structural polymorphism of DNA is a widely accepted property. A simple addition to this perception has been our recent finding, where a single nucleotide polymorphism (SNP) site present in a quasipalindromic sequence of beta-globin LCR exhibited a hairpin-duplex equilibrium. Our current studies explore that secondary structures adopted by individual complementary strands compete with formation of a perfect duplex. Using gel-electrophoresis, ultraviolet (UV)-thermal denaturation, circular dichroism (CD) techniques, we have demonstrated the structural transitions within a perfect duplex containing 11 bp quasipalindromic stretch (TGGGG(G/C)CCCCA), to hairpins and bulge duplex forms. The extended version of the 11 bp duplex, flanked by 5 bp on both sides also demonstrated conformational equilibrium between duplex and hairpin species. Gel-electrophoresis confirms that the duplex coexists with hairpin and bulge duplex/cruciform species. Further, in CD spectra of duplexes, presence of two overlapping positive peaks at 265 and 285 nm suggest the features of A- as well as B-type DNA conformation and show oligomer concentration dependence, manifested in A --> B transition. This indicates the possibility of an architectural switching at quasipalindromic region between linear duplex to a cruciform structure. Such DNA structural variations are likely to be found in the mechanics of molecular recognition and manipulation by proteins.

  6. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair.

    PubMed

    Budovec, Joseph J; Sudakoff, Gary S; Dzwierzynski, William W; Matloub, Hani S; Sanger, James R

    2006-04-01

    After the surgical repair of finger tendons finger range of motion may be limited by tendon rupture or adhesive scarring. Differentiating tendon rupture from adhesive scarring may be difficult clinically. Digital tendon sonography allows the evaluation of tendon integrity in a dynamic setting. Our objective was to determine if sonography could differentiate tendon rupture from adhesive scarring in patients who have had primary tendon repair. A retrospective review was performed of the radiographic, clinical, and surgical records of patients referred for finger sonography over a 2-year period. Twenty-eight digits in 21 patients were evaluated for finger tendon disruption after primary surgical repair. The diagnosis of complete tendon rupture was made when 1 or more of the following was identified: a gap separating the proximal and distal tendon margins, visualization of only the proximal tendon margin, or visualization of only the distal tendon margin. Adhesive scarring was diagnosed if the tendon appeared intact with abnormal peritendinous soft tissue abutting or partially encasing the tendon, with synovial sheath thickening, or with restricted tendon motion during dynamic evaluation. Sonography correctly identified tendon rupture or adhesive scarring in 27 of 28 digits with 1 false-positive case (sensitivity, 100%; specificity, 93%; positive-predictive value, 93%; negative-predictive value, 100%; accuracy, 96%). Sonography is an accurate modality for differentiating tendon rupture from adhesive scarring in patients with prior surgical tendon repair. Diagnostic, Level I.

  7. High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

    PubMed

    Steinborn, Marc; Friedmann, Melanie; Makowski, Christine; Hahn, Helmut; Hapfelmeier, Alexander; Juenger, Hendrik

    2016-04-01

    To evaluate the accuracy of high resolution transbulbar sonography for the estimation of intracranial pressure (ICP) in children. In children and adolescents with acute neurologic symptoms of various origin, transbulbar sonography was performed. Besides measurement of the optic nerve sheath diameter (ONSD), the ultrastructure of the subarachnoid space of the optic nerve sheath was evaluated. The results of transbulbar sonography were correlated with clinical data based on cross-sectional imaging, ICP measurement, and ophthalmologic examination. Eighty-one patients (age 3-17.8 years, mean 11.7 years) were included. In 25 children, cross-sectional imaging and ICP measurement revealed increased intracranial pressure. The mean ONSD was 6.85 ± 0.81 mm. Twenty patients (20/25, 80 %) had a microcystic appearance of the subarachnoid space of the optic nerve. In 56 children without evidence of increased intracranial pressure, the mean ONSD was 5.77 ± 0.48 mm. Forty-nine patients (49/56, 87.5 %) had a normal homogenous appearance of the subarachnoid space. The ONSD in children with increased intracranial pressure was significantly higher than in patients without (p < 0.001). High resolution transbulbar sonography of the optic nerve is a useful technique for the rapid and non-invasive estimation of intracranial pressure in children. Besides measurement of the optic nerve sheath diameter, evaluation of the ultrastructure of the subarachnoid space of the optic nerve is a helpful parameter.

  8. Potential digitization/compression techniques for Shuttle video

    NASA Technical Reports Server (NTRS)

    Habibi, A.; Batson, B. H.

    1978-01-01

    The Space Shuttle initially will be using a field-sequential color television system but it is possible that an NTSC color TV system may be used for future missions. In addition to downlink color TV transmission via analog FM links, the Shuttle will use a high resolution slow-scan monochrome system for uplink transmission of text and graphics information. This paper discusses the characteristics of the Shuttle video systems, and evaluates digitization and/or bandwidth compression techniques for the various links. The more attractive techniques for the downlink video are based on a two-dimensional DPCM encoder that utilizes temporal and spectral as well as the spatial correlation of the color TV imagery. An appropriate technique for distortion-free coding of the uplink system utilizes two-dimensional HCK codes.

  9. Object knowledge changes visual appearance: semantic effects on color afterimages.

    PubMed

    Lupyan, Gary

    2015-10-01

    According to predictive coding models of perception, what we see is determined jointly by the current input and the priors established by previous experience, expectations, and other contextual factors. The same input can thus be perceived differently depending on the priors that are brought to bear during viewing. Here, I show that expected (diagnostic) colors are perceived more vividly than arbitrary or unexpected colors, particularly when color input is unreliable. Participants were tested on a version of the 'Spanish Castle Illusion' in which viewing a hue-inverted image renders a subsequently shown achromatic version of the image in vivid color. Adapting to objects with intrinsic colors (e.g., a pumpkin) led to stronger afterimages than adapting to arbitrarily colored objects (e.g., a pumpkin-colored car). Considerably stronger afterimages were also produced by scenes containing intrinsically colored elements (grass, sky) compared to scenes with arbitrarily colored objects (books). The differences between images with diagnostic and arbitrary colors disappeared when the association between the image and color priors was weakened by, e.g., presenting the image upside-down, consistent with the prediction that color appearance is being modulated by color knowledge. Visual inputs that conflict with prior knowledge appear to be phenomenologically discounted, but this discounting is moderated by input certainty, as shown by the final study which uses conventional images rather than afterimages. As input certainty is increased, unexpected colors can become easier to detect than expected ones, a result consistent with predictive-coding models. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Multi-shell model of ion-induced nucleic acid condensation

    NASA Astrophysics Data System (ADS)

    Tolokh, Igor S.; Drozdetski, Aleksander V.; Pollack, Lois; Baker, Nathan A.; Onufriev, Alexey V.

    2016-04-01

    We present a semi-quantitative model of condensation of short nucleic acid (NA) duplexes induced by trivalent cobalt(iii) hexammine (CoHex) ions. The model is based on partitioning of bound counterion distribution around single NA duplex into "external" and "internal" ion binding shells distinguished by the proximity to duplex helical axis. In the aggregated phase the shells overlap, which leads to significantly increased attraction of CoHex ions in these overlaps with the neighboring duplexes. The duplex aggregation free energy is decomposed into attractive and repulsive components in such a way that they can be represented by simple analytical expressions with parameters derived from molecular dynamic simulations and numerical solutions of Poisson equation. The attractive term depends on the fractions of bound ions in the overlapping shells and affinity of CoHex to the "external" shell of nearly neutralized duplex. The repulsive components of the free energy are duplex configurational entropy loss upon the aggregation and the electrostatic repulsion of the duplexes that remains after neutralization by bound CoHex ions. The estimates of the aggregation free energy are consistent with the experimental range of NA duplex condensation propensities, including the unusually poor condensation of RNA structures and subtle sequence effects upon DNA condensation. The model predicts that, in contrast to DNA, RNA duplexes may condense into tighter packed aggregates with a higher degree of duplex neutralization. An appreciable CoHex mediated RNA-RNA attraction requires closer inter-duplex separation to engage CoHex ions (bound mostly in the "internal" shell of RNA) into short-range attractive interactions. The model also predicts that longer NA fragments will condense more readily than shorter ones. The ability of this model to explain experimentally observed trends in NA condensation lends support to proposed NA condensation picture based on the multivalent "ion binding shells."

  11. Color coded multiple access scheme for bidirectional multiuser visible light communications in smart home technologies

    NASA Astrophysics Data System (ADS)

    Tiwari, Samrat Vikramaditya; Sewaiwar, Atul; Chung, Yeon-Ho

    2015-10-01

    In optical wireless communications, multiple channel transmission is an attractive solution to enhancing capacity and system performance. A new modulation scheme called color coded multiple access (CCMA) for bidirectional multiuser visible light communications (VLC) is presented for smart home applications. The proposed scheme uses red, green and blue (RGB) light emitting diodes (LED) for downlink and phosphor based white LED (P-LED) for uplink to establish a bidirectional VLC and also employs orthogonal codes to support multiple users and devices. The downlink transmission for data user devices and smart home devices is provided using red and green colors from the RGB LEDs, respectively, while uplink transmission from both types of devices is performed using the blue color from P-LEDs. Simulations are conducted to verify the performance of the proposed scheme. It is found that the proposed bidirectional multiuser scheme is efficient in terms of data rate and performance. In addition, since the proposed scheme uses RGB signals for downlink data transmission, it provides flicker-free illumination that would lend itself to multiuser VLC system for smart home applications.

  12. Strand antagonism in RNAi: an explanation of differences in potency between intracellularly expressed siRNA and shRNA

    PubMed Central

    Jin, Xin; Sun, Tingting; Zhao, Chuanke; Zheng, Yongxiang; Zhang, Yufan; Cai, Weijing; He, Qiuchen; Taira, Kaz; Zhang, Lihe; Zhou, Demin

    2012-01-01

    Strategies to regulate gene function frequently use small interfering RNAs (siRNAs) that can be made from their shRNA precursors via Dicer. However, when the duplex components of these siRNA effectors are expressed from their respective coding genes, the RNA interference (RNAi) activity is much reduced. Here, we explored the mechanisms of action of shRNA and siRNA and found the expressed siRNA, in contrast to short hairpin RNA (shRNA), exhibits strong strand antagonism, with the sense RNA negatively and unexpectedly regulating RNAi. Therefore, we altered the relative levels of strands of siRNA duplexes during their expression, increasing the level of the antisense component, reducing the level of the sense component, or both and, in this way we were able to enhance the potency of the siRNA. Such vector-delivered siRNA attacked its target effectively. These findings provide new insight into RNAi and, in particular, they demonstrate that strand antagonism is responsible for making siRNA far less potent than shRNA. PMID:22039150

  13. An Autonomous Satellite Time Synchronization System Using Remotely Disciplined VC-OCXOs.

    PubMed

    Gu, Xiaobo; Chang, Qing; Glennon, Eamonn P; Xu, Baoda; Dempseter, Andrew G; Wang, Dun; Wu, Jiapeng

    2015-07-23

    An autonomous remote clock control system is proposed to provide time synchronization and frequency syntonization for satellite to satellite or ground to satellite time transfer, with the system comprising on-board voltage controlled oven controlled crystal oscillators (VC-OCXOs) that are disciplined to a remote master atomic clock or oscillator. The synchronization loop aims to provide autonomous operation over extended periods, be widely applicable to a variety of scenarios and robust. A new architecture comprising the use of frequency division duplex (FDD), synchronous time division (STDD) duplex and code division multiple access (CDMA) with a centralized topology is employed. This new design utilizes dual one-way ranging methods to precisely measure the clock error, adopts least square (LS) methods to predict the clock error and employs a third-order phase lock loop (PLL) to generate the voltage control signal. A general functional model for this system is proposed and the error sources and delays that affect the time synchronization are discussed. Related algorithms for estimating and correcting these errors are also proposed. The performance of the proposed system is simulated and guidance for selecting the clock is provided.

  14. Development of a new clot formation protocol for standardized in vitro investigations of sonothrombolysis.

    PubMed

    Roessler, Florian C; Teichert, Andrea; Ohlrich, Marcus; Marxsen, Jan H; Stellmacher, Florian; Tanislav, Christian; Seidel, Günter

    2014-11-30

    Agreement about the most suitable clot formation protocol for sonothrombolysis investigations is lacking. Lysis rates vary strongly owing to different test conditions and, thus, cannot be compared. We aim to establish a simple but physiologically grounded protocol for in vitro coagulation to enable standardized sonothrombolysis investigations. Clots were generated from platelet-rich plasma (PRP) obtained by centrifugation (10 min, 180 × g) of human venous blood (VB). PRP was mixed with the boundary layer formed between the supernatant and the erythrocyte layer. To achieve clots with different platelet counts, PRP was gradually substituted with platelet-free plasma (PFP), harvested from the supernatant of VB after centrifugation (10 min, 2570 × g). Clot types were examined for histological appearance, hydrodynamic resistance under physiological flows, and lysis rate measured by weight loss after a 2-h treatment with recombinant tissue plasminogen activator (rt-PA) (60 kU/ml). Lysis rates of the most suitable clot were measured after a 1-h treatment with rt-PA (60 kU/ml), and combined treatment with rt-PA and 2-MHz transcranial color-coded sonography (TCCS) (0.179 W/cm(2)) or 2-MHz transcranial Doppler (TCD) (0.457 W/cm(2)). With increased platelet count, the hydrodynamic resistance of the artificial clots increased, their histological appearance became more physiological, and lysis rates decreased. The most suitable clots consisted of 1.5-ml PRP, 2.0-ml PFP, and 0.5-ml boundary layer. Their lysis rates were 36.7 ± 7.8% (rt-PA), 40.8 ± 8.6% (rt-PA+TCCS), and 40.4 ± 8.3% (rt-PA+TCD). These systemic investigations were conducted for the first time. This protocol should be used for standardized sonothrombolysis investigations. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. 21 CFR 660.28 - Labeling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Labeling. 660.28 Section 660.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL... Reagents may be color coded with the specified color which shall be a visual match to a specific color...

  16. VizieR Online Data Catalog: Ultraviolet Excess Galaxies (Mitchell+ 1982)

    NASA Astrophysics Data System (ADS)

    Mitchell, K. J.; Brotzman, L. E.; Warnock, A.; Usher, P. D.

    2015-05-01

    The catalog contains a list of 412 faint galaxies selected for their apparent ultraviolet excess. The galaxies were selected from a 3-color (UBV) plate taken with the Palomar 48-inch Schmidt telescope. The 14-inch-square plates cover an area of 30 square degrees centered on Kapteyn Selected Area 28. The catalog includes running numbers, coordinates, color codes, magnitude codes, morphologies, diameters, and notes. The catalogued galaxies were selected by eye from the Palomar Schmidt 3-color (UBV) plate PS24771, centered on Kapteyn Selexted Area 28 and taken by Usher under conditions of good seeing and transparency. (1 data file).

  17. The Relative Noncognitive Traits of Sonographers: A Delphi Study

    ERIC Educational Resources Information Center

    Hagerty, Christina A.

    2012-01-01

    As the entrance to sonography programs continues to be competitive, community colleges are seeking methods to select students who will complete the program successfully and practice the standards of the profession. Although researchers have investigated the use of cognitive admission criteria in the selection of sonography candidates, more studies…

  18. Methods And Devices For Characterizing Duplex Nucleic Acid Molecules

    DOEpatents

    Akeson, Mark; Vercoutere, Wenonah; Haussler, David; Winters-Hilt, Stephen

    2005-08-30

    Methods and devices are provided for characterizing a duplex nucleic acid, e.g., a duplex DNA molecule. In the subject methods, a fluid conducting medium that includes a duplex nucleic acid molecule is contacted with a nanopore under the influence of an applied electric field and the resulting changes in current through the nanopore caused by the duplex nucleic acid molecule are monitored. The observed changes in current through the nanopore are then employed as a set of data values to characterize the duplex nucleic acid, where the set of data values may be employed in raw form or manipulated, e.g., into a current blockade profile. Also provided are nanopore devices for practicing the subject methods, where the subject nanopore devices are characterized by the presence of an algorithm which directs a processing means to employ monitored changes in current through a nanopore to characterize a duplex nucleic acid molecule responsible for the current changes. The subject methods and devices find use in a variety of applications, including, among other applications, the identification of an analyte duplex DNA molecule in a sample, the specific base sequence at a single nulceotide polymorphism (SNP), and the sequencing of duplex DNA molecules.

  19. Shedding light on serpent sight: the visual pigments of henophidian snakes.

    PubMed

    Davies, Wayne L; Cowing, Jill A; Bowmaker, James K; Carvalho, Livia S; Gower, David J; Hunt, David M

    2009-06-10

    The biologist Gordon Walls proposed his "transmutation" theory through the 1930s and the 1940s to explain cone-like morphology of rods (and vice versa) in the duplex retinas of modern-day reptiles, with snakes regarded as the epitome of his hypothesis. Despite Walls' interest, the visual system of reptiles, and in particular snakes, has been widely neglected in favor of studies of fishes and mammals. By analyzing the visual pigments of two henophidian snakes, Xenopeltis unicolor and Python regius, we show that both species express two cone opsins, an ultraviolet-sensitive short-wavelength-sensitive 1 (SWS1) (lambda(max) = 361 nm) pigment and a long-wavelength-sensitive (LWS) (lambda(max) = 550 nm) pigment, providing the potential for dichromatic color vision. They also possess rod photoreceptors which express the usual rod opsin (Rh1) pigment with a lambda(max) at 497 nm. This is the first molecular study of the visual pigments expressed in the photoreceptors of any snake species. The presence of a duplex retina and the characterization of LWS, SWS1, and Rh1 visual pigments in henophidian snakes implies that "lower" snakes do not provide support for Walls' transmutation theory, unlike some "higher" (caenophidian) snakes and other reptiles, such as geckos. More data from other snake lineages will be required to test this hypothesis further.

  20. Investigation of Hot Deformation Behavior of Duplex Stainless Steel Grade 2507

    NASA Astrophysics Data System (ADS)

    Kingklang, Saranya; Uthaisangsuk, Vitoon

    2017-01-01

    Recently, duplex stainless steels (DSSs) are being increasingly employed in chemical, petro-chemical, nuclear, and energy industries due to the excellent combination of high strength and corrosion resistance. Better understanding of deformation behavior and microstructure evolution of the material under hot working process is significant for achieving desired mechanical properties. In this work, plastic flow curves and microstructure development of the DSS grade 2507 were investigated. Cylindrical specimens were subjected to hot compression tests for different elevated temperatures and strain rates by a deformation dilatometer. It was found that stress-strain responses of the examined steel strongly depended on the forming rate and temperature. The flow stresses increased with higher strain rates and lower temperatures. Subsequently, predictions of the obtained stress-strain curves were done according to the Zener-Hollomon equation. Determination of material parameters for the constitutive model was presented. It was shown that the calculated flow curves agreed well with the experimental results. Additionally, metallographic examinations of hot compressed samples were performed by optical microscope using color tint etching. Area based phase fractions of the existing phases were determined for each forming condition. Hardness of the specimens was measured and discussed with the resulted microstructures. The proposed flow stress model can be used to design and optimize manufacturing process at elevated temperatures for the DSS.

  1. Color-coded visualization of magnetic resonance imaging multiparametric maps

    NASA Astrophysics Data System (ADS)

    Kather, Jakob Nikolas; Weidner, Anja; Attenberger, Ulrike; Bukschat, Yannick; Weis, Cleo-Aron; Weis, Meike; Schad, Lothar R.; Zöllner, Frank Gerrit

    2017-01-01

    Multiparametric magnetic resonance imaging (mpMRI) data are emergingly used in the clinic e.g. for the diagnosis of prostate cancer. In contrast to conventional MR imaging data, multiparametric data typically include functional measurements such as diffusion and perfusion imaging sequences. Conventionally, these measurements are visualized with a one-dimensional color scale, allowing only for one-dimensional information to be encoded. Yet, human perception places visual information in a three-dimensional color space. In theory, each dimension of this space can be utilized to encode visual information. We addressed this issue and developed a new method for tri-variate color-coded visualization of mpMRI data sets. We showed the usefulness of our method in a preclinical and in a clinical setting: In imaging data of a rat model of acute kidney injury, the method yielded characteristic visual patterns. In a clinical data set of N = 13 prostate cancer mpMRI data, we assessed diagnostic performance in a blinded study with N = 5 observers. Compared to conventional radiological evaluation, color-coded visualization was comparable in terms of positive and negative predictive values. Thus, we showed that human observers can successfully make use of the novel method. This method can be broadly applied to visualize different types of multivariate MRI data.

  2. Three-Dimensional Color Code Thresholds via Statistical-Mechanical Mapping.

    PubMed

    Kubica, Aleksander; Beverland, Michael E; Brandão, Fernando; Preskill, John; Svore, Krysta M

    2018-05-04

    Three-dimensional (3D) color codes have advantages for fault-tolerant quantum computing, such as protected quantum gates with relatively low overhead and robustness against imperfect measurement of error syndromes. Here we investigate the storage threshold error rates for bit-flip and phase-flip noise in the 3D color code (3DCC) on the body-centered cubic lattice, assuming perfect syndrome measurements. In particular, by exploiting a connection between error correction and statistical mechanics, we estimate the threshold for 1D stringlike and 2D sheetlike logical operators to be p_{3DCC}^{(1)}≃1.9% and p_{3DCC}^{(2)}≃27.6%. We obtain these results by using parallel tempering Monte Carlo simulations to study the disorder-temperature phase diagrams of two new 3D statistical-mechanical models: the four- and six-body random coupling Ising models.

  3. Small molecule-mediated duplex formation of nucleic acids with 'incompatible' backbones.

    PubMed

    Cafferty, Brian J; Musetti, Caterina; Kim, Keunsoo; Horowitz, Eric D; Krishnamurthy, Ramanarayanan; Hud, Nicholas V

    2016-04-07

    Proflavine, a known intercalator of DNA and RNA, promotes duplex formation by nucleic acids with natural and non-natural backbones that otherwise form duplexes with low thermal stability, and even some that show no sign of duplex formation in the absence of proflavine. These findings demonstrate the potential for intercalators to be used as cofactors for the assembly of rationally designed nucleic acid structures, and could provide fundamental insights regarding intercalation of natural nucleic acid duplexes.

  4. Imaging of Hereditary Hemorrhagic Telangiectasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carette, Marie-France, E-mail: marie-france.carette@tnn.aphp.fr; Nedelcu, Cosmina; Tassart, Marc

    This pictorial review is based on our experience of the follow-up of 120 patients at our multidisciplinary center for hereditary hemorrhagic telangiectasia (HHT). Rendu-Osler-Weber disease or HHT is a multiorgan autosomal dominant disorder with high penetrance, characterized by epistaxis, mucocutaneous telangiectasis, and visceral arteriovenous malformations (AVMs). The research on gene mutations is fundamental and family screening by clinical examination, chest X-ray, research of pulmonary shunting, and abdominal color Doppler sonography is absolutely necessary. The angioarchitecture of pulmonary AVMs can be studied by unenhanced multidetector computed tomography; however, all other explorations of liver, digestive bowels, or brain require administration of contrastmore » media. Magnetic resonance angiography is helpful for central nervous system screening, in particular for the spinal cord, but also for pulmonary, hepatic, and pelvic AVMs. Knowledge of the multiorgan involvement of HHT, mechanism of complications, and radiologic findings is fundamental for the correct management of these patients.« less

  5. [Elastography as an additional tool in breast sonography. Technical principles and clinical applications].

    PubMed

    Rjosk-Dendorfer, D; Reichelt, A; Clevert, D-A

    2014-03-01

    In recent years the use of elastography in addition to sonography has become a routine clinical tool for the characterization of breast masses. Whereas free hand compression elastography results in qualitative imaging of tissue stiffness due to induced compression, shear wave elastography displays quantitative information of tissue displacement. Recent studies have investigated the use of elastography in addition to sonography and improvement of specificity in differentiating benign from malignant breast masses could be shown. Therefore, additional use of elastography could help to reduce the number of unnecessary biopsies in benign breast lesions especially in category IV lesions of the ultrasound breast imaging reporting data system (US-BI-RADS).

  6. Reverse Stroop Effects with Untranslated Responses

    ERIC Educational Resources Information Center

    Blais, Chris; Besner, Derek

    2006-01-01

    Translation accounts have argued that the presence of a Stroop effect in the context of a nonvocal untranslated response is caused by verbal mediation. In its simplest form, color-labeled buttons are translated into a verbal code that interferes with color responses. On this logic, in the reverse Stroop task (identify the word; ignore the color),…

  7. The Instructional Effect of Color in Immediate and Delayed Retention.

    ERIC Educational Resources Information Center

    Lamberski, Richard J.

    The effect of verbal and visual (color or black/white) coding strategies in self-paced instruction and test materials in facilitating student retention on different cognitive tasks was studied. The 176 college student subjects received instruction and testing using varied combinations of color or black/white materials. Instructional materials were…

  8. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    ERIC Educational Resources Information Center

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  9. Color Vision and Performance on Color-Coded Cockpit Displays.

    PubMed

    Gaska, James P; Wright, Steven T; Winterbottom, Marc D; Hadley, Steven C

    Although there are numerous studies that demonstrate that color vision deficient (CVD) individuals perform less well than color vision normal (CVN) individuals in tasks that require discrimination or identification of colored stimuli, there remains a need to quantify the relationship between the type and severity of CVD and performance on operationally relevant tasks. Participants were classified as CVN (N = 45) or CVD (N = 49) using the Rabin cone contrast test, which is the standard color vision screening test used by the United States Air Force. In the color condition, test images that were representative of the size, shape, and color of symbols and lines used on fifth-generation fighter aircraft displays were used to measure operational performance. In the achromatic condition, all symbols and lines had the same chromaticity but differed in luminance. Subjects were asked to locate and discriminate between friend vs. foe symbols (red vs. green, or brighter vs. dimmer) while speed and accuracy were recorded. Increasing color deficiency was associated with decreasing speed and accuracy for the color condition (R 2 > 0.2), but not for the achromatic condition. Mean differences between CVN and CVD individuals showed the same pattern. Although lower CCT scores are clearly associated with lower performance in color related tasks, the magnitude of the performance loss was relatively small and there were multiple examples of high-performing CVD individuals who had higher operational scores than low-performing CVN individuals. Gaska JP, Wright ST, Winterbottom MD, Hadley SC. Color vision and performance on color-coded cockpit displays. Aerosp Med Hum Perform. 2016; 87(11):921-927.

  10. Transbulbar B-Mode Sonography in Multiple Sclerosis: Clinical and Biological Relevance.

    PubMed

    De Masi, Roberto; Orlando, Stefania; Conte, Aldo; Pasca, Sergio; Scarpello, Rocco; Spagnolo, Pantaleo; Muscella, Antonella; De Donno, Antonella

    2016-12-01

    Optic nerve sheath diameter quantification by transbulbar B-mode sonography is a recently validated technique, but its clinical relevance in relapse-free multiple sclerosis patients remains unexplored. In an open-label, comparative, cross-sectional study, we aimed to assess possible differences between patients and healthy controls in terms of optic nerve sheath diameter and its correlation with clinical/paraclinical parameters in this disease. Sixty unselected relapse-free patients and 35 matched healthy controls underwent transbulbar B-mode sonography. Patients underwent routine neurologic examination, brain magnetic resonance imaging and visual evoked potential tests. The mean optic nerve sheath diameter 3 and 5 mm from the eyeball was 22-25% lower in patients than controls and correlated with the Expanded Disability Status Scale (r = -0.34, p = 0.048, and r = -0.32, p = 0.042, respectively). We suggest that optic nerve sheath diameter quantified by transbulbar B-mode sonography should be included in routine assessment of the disease as an extension of the neurologic examination. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Dwell-Time Distribution, Long Pausing and Arrest of Single-Ribosome Translation through the mRNA Duplex.

    PubMed

    Xie, Ping

    2015-10-09

    Proteins in the cell are synthesized by a ribosome translating the genetic information encoded on the single-stranded messenger RNA (mRNA). It has been shown that the ribosome can also translate through the duplex region of the mRNA by unwinding the duplex. Here, based on our proposed model of the ribosome translation through the mRNA duplex we study theoretically the distribution of dwell times of the ribosome translation through the mRNA duplex under the effect of a pulling force externally applied to the ends of the mRNA to unzip the duplex. We provide quantitative explanations of the available single molecule experimental data on the distribution of dwell times with both short and long durations, on rescuing of the long paused ribosomes by raising the pulling force to unzip the duplex, on translational arrests induced by the mRNA duplex and Shine-Dalgarno(SD)-like sequence in the mRNA. The functional consequences of the pauses or arrests caused by the mRNA duplex and the SD sequence are discussed and compared with those obtained from other types of pausing, such as those induced by "hungry" codons or interactions of specific sequences in the nascent chain with the ribosomal exit tunnel.

  12. Thermal stability of DNA quadruplex-duplex hybrids.

    PubMed

    Lim, Kah Wai; Khong, Zi Jian; Phan, Anh Tuân

    2014-01-14

    DNA has the capacity to adopt several distinct structural forms, such as duplex and quadruplex helices, which have been implicated in cellular processes and shown to exhibit important functional properties. Quadruplex-duplex hybrids, generated from the juxtaposition of these two structural elements, could find applications in therapeutics and nanotechnology. Here we used NMR and CD spectroscopy to investigate the thermal stability of two classes of quadruplex-duplex hybrids comprising fundamentally distinct modes of duplex and quadruplex connectivity: Construct I involves the coaxial orientation of the duplex and quadruplex helices with continual base stacking across the two components; Construct II involves the orthogonal orientation of the duplex and quadruplex helices with no base stacking between the two components. We have found that for both constructs, the stability of the quadruplex generally increases with the length of the stem-loop incorporated, with respect to quadruplexes comprising nonstructured loops of the same length, which showed a continuous drop in stability with increasing loop length. The stability of these complexes, particularly Construct I, can be substantially influenced by the base-pair steps proximal to the quadruplex-duplex junction. Bulges at the junction are largely detrimental to the adoption of the desired G-quadruplex topology for Construct I but not for Construct II. These findings should facilitate future design and prediction of quadruplex-duplex hybrids.

  13. Distance-dependent duplex DNA destabilization proximal to G-quadruplex/i-motif sequences

    PubMed Central

    König, Sebastian L. B.; Huppert, Julian L.; Sigel, Roland K. O.; Evans, Amanda C.

    2013-01-01

    G-quadruplexes and i-motifs are complementary examples of non-canonical nucleic acid substructure conformations. G-quadruplex thermodynamic stability has been extensively studied for a variety of base sequences, but the degree of duplex destabilization that adjacent quadruplex structure formation can cause has yet to be fully addressed. Stable in vivo formation of these alternative nucleic acid structures is likely to be highly dependent on whether sufficient spacing exists between neighbouring duplex- and quadruplex-/i-motif-forming regions to accommodate quadruplexes or i-motifs without disrupting duplex stability. Prediction of putative G-quadruplex-forming regions is likely to be assisted by further understanding of what distance (number of base pairs) is required for duplexes to remain stable as quadruplexes or i-motifs form. Using oligonucleotide constructs derived from precedented G-quadruplexes and i-motif-forming bcl-2 P1 promoter region, initial biophysical stability studies indicate that the formation of G-quadruplex and i-motif conformations do destabilize proximal duplex regions. The undermining effect that quadruplex formation can have on duplex stability is mitigated with increased distance from the duplex region: a spacing of five base pairs or more is sufficient to maintain duplex stability proximal to predicted quadruplex/i-motif-forming regions. PMID:23771141

  14. Dwell-Time Distribution, Long Pausing and Arrest of Single-Ribosome Translation through the mRNA Duplex

    PubMed Central

    Xie, Ping

    2015-01-01

    Proteins in the cell are synthesized by a ribosome translating the genetic information encoded on the single-stranded messenger RNA (mRNA). It has been shown that the ribosome can also translate through the duplex region of the mRNA by unwinding the duplex. Here, based on our proposed model of the ribosome translation through the mRNA duplex we study theoretically the distribution of dwell times of the ribosome translation through the mRNA duplex under the effect of a pulling force externally applied to the ends of the mRNA to unzip the duplex. We provide quantitative explanations of the available single molecule experimental data on the distribution of dwell times with both short and long durations, on rescuing of the long paused ribosomes by raising the pulling force to unzip the duplex, on translational arrests induced by the mRNA duplex and Shine-Dalgarno(SD)-like sequence in the mRNA. The functional consequences of the pauses or arrests caused by the mRNA duplex and the SD sequence are discussed and compared with those obtained from other types of pausing, such as those induced by “hungry” codons or interactions of specific sequences in the nascent chain with the ribosomal exit tunnel. PMID:26473825

  15. Thyroid Ultrasonography in Differentiation between Graves' Disease and Hashimoto's Thyroiditis.

    PubMed

    Pishdad, P; Pishdad, G R; Tavanaa, S; Pishdad, R; Jalli, R

    2017-03-01

    Graves' disease and Hashimoto's thyroiditis are the most common causes of hyper and hypothyroidism, respectively. Differentiation of these 2 diseases, if the patient is euthyroid, may sometimes be extremely difficult on the basis of clinical and laboratory findings. The purpose of this study was to determine the sensitivity and specificity of gray scale sonography in differentiation of Graves' disease from Hashimoto's thyroiditis. This study included 149 patients divided into three groups, patients with Graves' disease (34 patients, mean age = 36.8 ± 10.17 years), Patients with Hashimoto's thyroiditis (62 patients, mean age = 33.4 ± 12.16 years) and control group (53 healthy people, mean age = 34.74 ± 16.87 years). Members of all groups were referred to a single radiologist for thyroid sonography for evaluation of thyroid echogenicity pattern. A total of 117 women and 32 men were examined by sonography. The most common sonographic pattern in Hashimoto and Graves' was homogenous hypo-echogenicity which was observed in 45.2% and 47.1% of cases, respectively. Peripheral hypo-echogenicity pattern was seen in 40.3% of Hashimoto's group with 100% specificity and 40.3% sensitivity. Central-hypoechogenic pattern was observed in 17.6% of Graves' group with 100% and 17.6% specificity and sensitivity, respectively. Our findings indicate that sonography has high specificity but low sensitivity in the diagnosis of either Graves' disease or Hashimoto's thyroiditis. It is therefore not possible to differentiate between these two diseases using sonography alone. Confirmation by laboratory data is also needed.

  16. Quantitative analysis of scapholunate diastasis using stress speckle-tracking sonography: a proof-of-concept and feasibility study.

    PubMed

    Gondim Teixeira, Pedro Augusto; Badr, Sammy; Hossu, Gabriela; Lefebvre, Guillaume; Abou Arab, Waled; Blum, Alain; Cotten, Anne

    2017-12-01

    To evaluate the feasibility and potential clinical applicability of speckle-tracking sonography for the dynamic evaluation of the scapholunate diastasis during stress manoeuvres. Two readers used speckle tracking sonography to evaluate scapholunate diastasis during a clenching fist manoeuver in 30 normal wrists. Scapholunate peak strain, mean scapholunate diastasis and the diastasis variation coefficient were analysed. IRB exemption was granted for this study. Conventional and stress wrist radiographs of 26 patients with and without a scapholunate ligament tear were retrospectively analysed to ascertain the range of variation in scapholunate diastasis. Speckle-tracking parameters in normal wrists were similar between the two readers (p  > 0.2061). The maximal scapholunate peak strain during stress was relatively low (<0.34-0.47 mm). The normal radiographic diastasis amplitude was similar to maximal strain peak values in normal volunteers (0.49 ± 0.51 mm). The radiographic diastasis amplitude in cases of scapholunate ligament tears was 1.48 ± 0.78 mm, which was higher than the 95% confidence interval of the scapholunate gap peak strain. Speckle-tracking sonography could represent an interesting alternative for stress evaluation of the scapholunate ligament in patients with scapholunate diastasis. • Speckle-tracking sonography can assess scapholunate diastasis under stress testing. • Scapholunate gap shows little variation under stress in healthy volunteers. • Scapholunate gap measurements are influenced by grip strength. • Sex and BMI have a significant influence on strain measurements.

  17. Comparison of phase-contrast MR imaging and endovascular sonography for intracranial blood flow velocity measurements.

    PubMed

    Schneiders, J J; Ferns, S P; van Ooij, P; Siebes, M; Nederveen, A J; van den Berg, R; van Lieshout, J; Jansen, G; vanBavel, E; Majoie, C B

    2012-10-01

    Local hemodynamic information may help to stratify rupture risk of cerebral aneurysms. Patient-specific modeling of cerebral hemodynamics requires accurate data on BFV in perianeurysmal arteries as boundary conditions for CFD. The aim was to compare the BFV measured with PC-MR imaging with that obtained by using intra-arterial Doppler sonography and to determine interpatient variation in intracranial BFV. In 10 patients with unruptured intracranial aneurysms, BFV was measured in the cavernous ICA with PC-MR imaging in conscious patients before treatment, and measured by using an intra-arterial Doppler sonography wire when the patient was anesthetized with either propofol (6 patients) or sevoflurane (4 patients). Both techniques identified a pulsatile blood flow pattern in cerebral arteries. PSV differed >50 cm/s between patients. A mean velocity of 41.3 cm/s (95% CI, 39.3-43.3) was measured with PC-MR imaging. With intra-arterial Doppler sonography, a mean velocity of 29.3 cm/s (95% CI, 25.8-32.8) was measured with the patient under propofol-based intravenous anesthesia. In patients under sevoflurane-based inhaled anesthesia, a mean velocity of 44.9 cm/s (95% CI, 40.6-49.3) was measured. We showed large differences in BFV between patients, emphasizing the importance of using patient-specific hemodynamic boundary conditions in CFD. PC-MR imaging measurements of BFV in conscious patients were comparable with those obtained with the intra-arterial Doppler sonography when the patient was anesthetized with a sevoflurane-based inhaled anesthetic.

  18. Dedicated training program for shoulder sonography: the results of a quality program reverberate with everyone.

    PubMed

    Delzell, Patricia B; Boyle, Alex; Schneider, Erika

    2015-06-01

    The purpose of this study was to define and report on the effect of a comprehensive musculoskeletal sonography training program to improve accuracy (sensitivity and specificity) for the diagnosis of rotator cuff tears in relatively inexperienced operators. Before the training program was implemented, radiologists (n = 12) had a mean of 2 years (range, <1-12 years) of experience performing and interpreting musculoskeletal sonography. Pre- and post-training shoulder sonographic results were compared to surgical reports or, in their absence, to shoulder magnetic resonance imaging or computed tomographic arthrographic results if within 2 months of the sonographic examination. A total of 82 patients were included in the pre-training group (January 2010-December 2011), and 50 patients were included in the post-training group (January 2012-June 2013). The accuracy, sensitivity, specificity, and positive and negative predictive values were determined for the presence or absence of supraspinatus and infraspinatus tendon tears. After implementation of the training program, the sensitivity of sonography for detecting full-thickness rotator cuff tears increased by 14%, and the sensitivity for detecting partial-thickness rotator cuff tears increased by 3%. Quality improvement programs and acquisition standardization along with ongoing, focused case conferences for the entire care team increased the sensitivity of shoulder sonography for diagnosing both full- and partial-thickness rotator cuff tears, independent of the years of operator experience. © 2015 by the American Institute of Ultrasound in Medicine.

  19. Backbone conformation affects duplex initiation and duplex propagation in hybridisation of synthetic H-bonding oligomers.

    PubMed

    Iadevaia, Giulia; Núñez-Villanueva, Diego; Stross, Alexander E; Hunter, Christopher A

    2018-06-06

    Synthetic oligomers equipped with complementary H-bond donor and acceptor side chains form multiply H-bonded duplexes in organic solvents. Comparison of the duplex forming properties of four families of oligomers with different backbones shows that formation of an extended duplex with three or four inter-strand H-bonds is more challenging than formation of complexes that make only two H-bonds. The stabilities of 1 : 1 complexes formed between length complementary homo-oligomers equipped with either phosphine oxide or phenol recognition modules were measured in toluene. When the backbone is very flexible (pentane-1,5-diyl thioether), the stability increases uniformly by an order of magnitude for each additional base-pair added to the duplex: the effective molarities for formation of the first intramolecular H-bond (duplex initiation) and subsequent intramolecular H-bonds (duplex propagation) are similar. This flexible system is compared with three more rigid backbones that are isomeric combinations of an aromatic ring and methylene groups. One of the rigid systems behaves in exactly the same way as the flexible backbone, but the other two do not. For these systems, the effective molarity for formation of the first intramolecular H-bond is the same as that found for the other two backbones, but additional H-bonds are not formed between the longer oligomers. The effective molarities are too low for duplex propagation in these systems, because the oligomer backbones cannot adopt conformations compatible with formation of an extended duplex.

  20. Men who have sex with men’s attitudes toward using color-coded wristbands to facilitate sexual communication at sex parties

    PubMed Central

    Grov, Christian; Cruz, Jackeline; Parsons, Jeffrey T.

    2014-01-01

    Sex parties are environments where men who have sex with men (MSM) have the opportunity to have sex with multiple partners over a brief period of time. Dim lighting and non-verbal communication are characteristics of sex parties that make sexual communication more challenging. We report on qualitative data from 47 MSM who attended sex parties in New York City. Participants responded to distinct hypothetical scenarios involving the use of color-coded wristbands to communicate (1) condom use preferences, (2) sexual position (e.g., top, bottom) and (3) HIV status at sex parties. The majority had positive-to-neutral attitudes toward color-coded wristbands to indicate (1) condom use preference and (2) sexual position (70.8%, 75.0% HIV-positive; 63.6%, 81.8%, HIV-negative respectively). These men cited that wristbands would facilitate the process of pursuing partners with similar interests while also avoiding the discomforts of verbal communication. In contrast, 41.7% of HIV-positive and 50.0% of HIV-negative men expressed unfavorable attitudes to using wristbands to communicate HIV status. These men cited the potential for HIV-status discrimination as well as suspicions around dishonest disclosure. Although participants were receptive to utilizing color-coded wristbands at sex parties to convey certain information, it may be unfeasible to use wristbands to communicate HIV status. PMID:24659929

  1. Water-evaporation reduction by duplex films: application to the human tear film.

    PubMed

    Cerretani, Colin F; Ho, Nghia H; Radke, C J

    2013-09-01

    Water-evaporation reduction by duplex-oil films is especially important to understand the physiology of the human tear film. Secreted lipids, called meibum, form a duplex film that coats the aqueous tear film and purportedly reduces tear evaporation. Lipid-layer deficiency is correlated with the occurrence of dry-eye disease; however, in-vitro experiments fail to show water-evaporation reduction by tear-lipid duplex films. We review the available literature on water-evaporation reduction by duplex-oil films and outline the theoretical underpinnings of spreading and evaporation kinetics that govern behavior of these systems. A dissolution-diffusion model unifies the data reported in the literature and identifies dewetting of duplex films into lenses as a key challenge to obtaining significant evaporation reduction. We develop an improved apparatus for measuring evaporation reduction by duplex-oil films including simultaneous assessment of film coverage, stability, and temperature, all under controlled external mass transfer. New data reported in this study fit into the larger body of work conducted on water-evaporation reduction by duplex-oil films. Duplex-oil films of oxidized mineral oil/mucin (MOx/BSM), human meibum (HM), and bovine meibum (BM) reduce water evaporation by a dissolution-diffusion mechanism, as confirmed by agreement between measurement and theory. The water permeability of oxidized-mineral-oil duplex films agrees with those reported in the literature, after correction for the presence of mucin. We find that duplex-oil films of bovine and human meibum at physiologic temperature reduce water evaporation only 6-8% for a 100-nm film thickness pertinent to the human tear film. Comparison to in-vivo human tear-evaporation measurements is inconclusive because evaporation from a clean-water surface is not measured and because the mass-transfer resistance is not characterized. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Color categories are not universal: new evidence from traditional and western cultures

    NASA Astrophysics Data System (ADS)

    Roberson, Debi D.; Davidoff, Jules; Davies, Ian R. L.

    2002-06-01

    Evidence presented supports the linguistic relativity of color categories in three different paradigms. Firstly, a series of cross-cultural investigations, which had set out to replicate the seminal work of Rosch Heider with the Dani of New Guinea, failed to find evidence of a set of universal color categories. Instead, we found evidence of linguistic relativity in both populations tested. Neither participants from a Melanesian hunter-gatherer culture, nor those from an African pastoral tribe, whose languages both contain five color terms, showed a cognitive organization of color resembling that of English speakers. Further, Melanesian participants showed evidence of Categorical Perception, but only at their linguistic category boundaries. Secondly, in native English speakers verbal interference was found to selectively remove the defining features of Categorical Perception. Under verbal interference, the greater accuracy normally observed for cross-category judgements compared to within-category judgements disappeared. While both visual and verbal codes may be employed in the recognition memory of colors, participants only make use of verbal coding when demonstrating Categorical Perception. Thirdly, in a brain- damaged patient suffering from a naming disorder, the loss of labels radically impaired his ability to categorize colors. We conclude that language affects both the perception of and memory for colors.

  3. Management of non-neoplastic ovarian cysts with sclerotherapy.

    PubMed

    Kafali, H; Yurtseven, S; Atmaca, F; Ozardali, I

    2003-04-01

    To evaluate sclerotherapy with alcohol and erythromycin in the management of simple ovarian cysts. Twenty-four simple ovarian cysts were subjected to sclerotherapy with alcohol and erythromycin. All procedures were performed under local anesthesia and in an outpatient setting. Cytological examination was carried out in all cases and two patients were excluded from the study because of suspicious cytological results. The patients were followed up monthly with color Doppler sonography for more than 12 months. Cyst fluid was serous in 17 cases and dark-chocolate colored in seven cases. The volume of aspirated fluid ranged from 100 to 220 ml. The size of ovarian masses and cyst-wall thickness ranged from 5.5 to 8.5 cm and 1.5 to 5 mm, respectively. Cytological analysis of 15 cysts revealed acellular sediment, seven cysts were compatible with endometrioma, and two were reported as suspicious. During the 12-month follow-up, seven cyst recurrences were detected. Aspiration and sclerotherapy with alcohol and erythromycin are followed by a relatively high recurrence rate when the aspirate is bloody. However, patients with a simple cyst that is painful or liable to torsion could benefit from sclerotherapy. Such patients, who are at low risk for malignancy, are relieved with sclerotherapy while avoiding surgery.

  4. Multi-shell model of ion-induced nucleic acid condensation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolokh, Igor S.; Drozdetski, Aleksander V.; Pollack, Lois

    We present a semi-quantitative model of condensation of short nucleic acid (NA) duplexes induced by trivalent cobalt(III) hexammine (CoHex) ions. The model is based on partitioning of bound counterion distribution around single NA duplex into “external” and “internal” ion binding shells distinguished by the proximity to duplex helical axis. In the aggregated phase the shells overlap, which leads to significantly increased attraction of CoHex ions in these overlaps with the neighboring duplexes. The duplex aggregation free energy is decomposed into attractive and repulsive components in such a way that they can be represented by simple analytical expressions with parameters derivedmore » from molecular dynamic simulations and numerical solutions of Poisson equation. The attractive term depends on the fractions of bound ions in the overlapping shells and affinity of CoHex to the “external” shell of nearly neutralized duplex. The repulsive components of the free energy are duplex configurational entropy loss upon the aggregation and the electrostatic repulsion of the duplexes that remains after neutralization by bound CoHex ions. The estimates of the aggregation free energy are consistent with the experimental range of NA duplex condensation propensities, including the unusually poor condensation of RNA structures and subtle sequence effects upon DNA condensation. The model predicts that, in contrast to DNA, RNA duplexes may condense into tighter packed aggregates with a higher degree of duplex neutralization. An appreciable CoHex mediated RNA-RNA attraction requires closer inter-duplex separation to engage CoHex ions (bound mostly in the “internal” shell of RNA) into short-range attractive interactions. The model also predicts that longer NA fragments will condense more readily than shorter ones. The ability of this model to explain experimentally observed trends in NA condensation lends support to proposed NA condensation picture based on the multivalent “ion binding shells.”.« less

  5. Multi-shell model of ion-induced nucleic acid condensation

    PubMed Central

    Tolokh, Igor S.; Drozdetski, Aleksander V.; Pollack, Lois; Onufriev, Alexey V.

    2016-01-01

    We present a semi-quantitative model of condensation of short nucleic acid (NA) duplexes induced by trivalent cobalt(iii) hexammine (CoHex) ions. The model is based on partitioning of bound counterion distribution around single NA duplex into “external” and “internal” ion binding shells distinguished by the proximity to duplex helical axis. In the aggregated phase the shells overlap, which leads to significantly increased attraction of CoHex ions in these overlaps with the neighboring duplexes. The duplex aggregation free energy is decomposed into attractive and repulsive components in such a way that they can be represented by simple analytical expressions with parameters derived from molecular dynamic simulations and numerical solutions of Poisson equation. The attractive term depends on the fractions of bound ions in the overlapping shells and affinity of CoHex to the “external” shell of nearly neutralized duplex. The repulsive components of the free energy are duplex configurational entropy loss upon the aggregation and the electrostatic repulsion of the duplexes that remains after neutralization by bound CoHex ions. The estimates of the aggregation free energy are consistent with the experimental range of NA duplex condensation propensities, including the unusually poor condensation of RNA structures and subtle sequence effects upon DNA condensation. The model predicts that, in contrast to DNA, RNA duplexes may condense into tighter packed aggregates with a higher degree of duplex neutralization. An appreciable CoHex mediated RNA-RNA attraction requires closer inter-duplex separation to engage CoHex ions (bound mostly in the “internal” shell of RNA) into short-range attractive interactions. The model also predicts that longer NA fragments will condense more readily than shorter ones. The ability of this model to explain experimentally observed trends in NA condensation lends support to proposed NA condensation picture based on the multivalent “ion binding shells.” PMID:27389241

  6. Symbolic comparisons of objects on color attributes.

    PubMed

    Paivio, A; te Linde, J

    1980-11-01

    Symbolic comparisons of object brightness and color were investigated in two experiments using words and outline drawings as stimuli. Both experiments yielded orderly symbolic distance effects. Contrary to prediction, no reliable picture advantages emerged. For color comparison, individual differences in word fluency and color memory predicted decision time with word stimuli. These results contrast sharply with those of previous comparison studies involving concrete dimensions. The results are discussed in terms of dual-coding theory and the role of verbal mechanisms in memory for object color.

  7. The Remote Analysis Station (RAS) as an instructional system

    NASA Technical Reports Server (NTRS)

    Rogers, R. H.; Wilson, C. L.; Dye, R. H.; Jaworski, E.

    1981-01-01

    "Hands-on" training in LANDSAT data analysis techniques can be obtained using a desk-top, interactive remote analysis station (RAS) which consists of a color CRT imagery display, with alphanumeric overwrite and keyboard, as well as a cursor controller and modem. This portable station can communicate via modem and dial-up telephone with a host computer at 1200 baud or it can be hardwired to a host computer at 9600 baud. A Z80 microcomputer controls the display refresh memory and remote station processing. LANDSAT data is displayed as three-band false-color imagery, one-band color-sliced imagery, or color-coded processed imagery. Although the display memory routinely operates at 256 x 256 picture elements, a display resolution of 128 x 128 can be selected to fill the display faster. In the false color mode the computer packs the data into one 8-bit character. When the host is not sending pictorial information the characters sent are in ordinary ASCII code. System capabilities are described.

  8. Relative value of physical examination, mammography, and breast sonography in evaluating the size of the primary tumor and regional lymph node metastases in women receiving neoadjuvant chemotherapy for locally advanced breast carcinoma.

    PubMed

    Herrada, J; Iyer, R B; Atkinson, E N; Sneige, N; Buzdar, A U; Hortobagyi, G N

    1997-09-01

    The purpose of this study was to correlate physical examination and sonographic and mammographic measurements of breast tumors and regional lymph nodes with pathological findings and to evaluate the effect of neoadjuvant chemotherapy on clinical Tumor-Node-Metastasis stage by noninvasive methods. This was a retrospective analysis of 100 patients with locally advanced breast cancer registered and treated in prospective trials of neoadjuvant chemotherapy. All patients received four cycles of a doxorubicin-containing regimen and had noninvasive evaluation of the primary tumor and regional lymph nodes before and after neoadjuvant chemotherapy by physical examination, sonography, and mammography and underwent breast surgery and axillary dissection within 5 weeks after completion of neoadjuvant chemotherapy. The correlations between clinical and pathological measurements were determined by Spearman rank correlation analysis. A proportional odds model was used to examine predictive values. Eighty-three patients had both a clinically detectable primary tumor and lymph node metastases. Sixty-four patients had a decrease in Tumor-Node-Metastasis stage after chemotherapy. For 54% of patients, there was concordance in clinical response between the primary tumor and lymph node compartment; for the rest, results were discordant. Physical examination correlated best with pathological findings in the measurement of the primary tumor (P = 0.0003), whereas sonography was the most accurate predictor of size for axillary lymph nodes (P = 0.0005). The combination of physical examination and mammography worked best for assessment of the primary tumor (P = 0.003), whereas combining physical examination with sonography gave optimal evaluation of regional lymph nodes (P = 0.0001). In conclusion, physical examination is the best noninvasive predictor of the real size of locally advanced primary breast cancer, whereas sonography correlates better with the real dimensions of axillary lymph nodes. The combination of physical examination with either mammography or sonography significantly improves the accuracy of noninvasive assessment of tumor dimensions.

  9. Dissociation between awareness and spatial coding: evidence from unilateral neglect.

    PubMed

    Treccani, Barbara; Cubelli, Roberto; Sellaro, Roberta; Umiltà, Carlo; Della Sala, Sergio

    2012-04-01

    Prevalent theories about consciousness propose a causal relation between lack of spatial coding and absence of conscious experience: The failure to code the position of an object is assumed to prevent this object from entering consciousness. This is consistent with influential theories of unilateral neglect following brain damage, according to which spatial coding of neglected stimuli is defective, and this would keep their processing at the nonconscious level. Contrary to this view, we report evidence showing that spatial coding and consciousness can dissociate. A patient with left neglect, who was not aware of contralesional stimuli, was able to process their color and position. However, in contrast to (ipsilesional) consciously perceived stimuli, color and position of neglected stimuli were processed separately. We propose that individual object features, including position, can be processed without attention and consciousness and that conscious perception of an object depends on the binding of its features into an integrated percept.

  10. Evaluation of Freehand B-Mode and Power-Mode 3D Ultrasound for Visualisation and Grading of Internal Carotid Artery Stenosis.

    PubMed

    Pelz, Johann Otto; Weinreich, Anna; Karlas, Thomas; Saur, Dorothee

    2017-01-01

    Currently, colour-coded duplex sonography (2D-CDS) is clinical standard for detection and grading of internal carotid artery stenosis (ICAS). However, unlike angiographic imaging modalities, 2D-CDS assesses ICAS by its hemodynamic effects rather than luminal changes. Aim of this study was to evaluate freehand 3D ultrasound (3DUS) for direct visualisation and quantification of ICAS. Thirty-seven patients with 43 ICAS were examined with 2D-CDS as reference standard and with freehand B-mode respectively power-mode 3DUS. Stenotic value of 3D reconstructed ICAS was calculated as distal diameter respectively distal cross-sectional area (CSA) reduction percentage and compared with 2D-CDS. There was a trend but no significant difference in successful 3D reconstruction of ICAS between B-mode and power mode (examiner 1 {Ex1} 81% versus 93%, examiner 2 {Ex2} 84% versus 88%). Inter-rater agreement was best for power-mode 3DUS and assessment of stenotic value as distal CSA reduction percentage (intraclass correlation coefficient {ICC} 0.90) followed by power-mode 3DUS and distal diameter reduction percentage (ICC 0.81). Inter-rater agreement was poor for B-mode 3DUS (ICC, distal CSA reduction 0.36, distal diameter reduction 0.51). Intra-rater agreement for power-mode 3DUS was good for both measuring methods (ICC, distal CSA reduction 0.88 {Ex1} and 0.78 {Ex2}; ICC, distal diameter reduction 0.83 {Ex1} and 0.76 {Ex2}). In comparison to 2D-CDS inter-method agreement was good and clearly better for power-mode 3DUS (ICC, distal diameter reduction percentage: Ex1 0.85, Ex2 0.78; distal CSA reduction percentage: Ex1 0.63, Ex2 0.57) than for B-mode 3DUS (ICC, distal diameter reduction percentage: Ex1 0.40, Ex2 0.52; distal CSA reduction percentage: Ex1 0.15, Ex2 0.51). Non-invasive power-mode 3DUS is superior to B-mode 3DUS for imaging and quantification of ICAS. Thereby, further studies are warranted which should now compare power-mode 3DUS with the angiographic gold standard imaging modalities for quantification of ICAS, i.e. with CTA or CE-MRA.

  11. Duplex gall bladder: bystander or culprit.

    PubMed

    Kumar, Jogender; Yadav, Arushi

    2017-08-30

    Gall bladder (GB) duplication is a rare anatomical malformation, which can be detected by preoperative imaging study. We present a case of duplex gall bladder in a 14-year-old boy who presented with abdominal pain. On ultrasound, he had right nephrolithiasis and duplex gall bladder. Duplex gall bladder was confirmed on MR cholangiopancreatography. There was a dilemma for surgical management of duplex gall bladder; however, he became asymptomatic after conservative treatment. Prophylactic surgery is not recommended for asymptomatic incidentally detected duplex gall bladder. Radiologists and paediatric surgeons should be sensitised about the exact anatomy of this entity. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Enhancing the corrosion resistance of the 2205 duplex stainless steel bipolar plates in PEMFCs environment by surface enriched molybdenum

    NASA Astrophysics Data System (ADS)

    Jinlong, Lv; Zhuqing, Wang; Tongxiang, Liang; Ken, Suzuki; Hideo, Miura

    Surface molybdenum enrichment on 2205 duplex stainless steel was obtained by the ball milling technique. The electrochemical results showed molybdenum enrichment on the surface of 2205 duplex stainless steel improved its corrosion resistance in a typical proton exchange membrane fuel cell environment. This was mainly attributed to higher molybdenum content in the passive film formed on 2205 duplex stainless steel after ball milling. The decreased donor and acceptor concentrations improved significantly the corrosion resistance of surface molybdenum-enriched 2205 duplex stainless steel bipolar plates in the simulated cathodic proton exchange membrane fuel cells environment. In addition, the interfacial contact resistance of the 2205 duplex stainless steel bipolar plates slightly decreased due to surface molybdenum enrichment.

  13. Color-Coded Labels Cued Nurses to Adhere to Central Line Connector Change.

    PubMed

    Morrison, Theresa Lynch; Laney, Christina; Foglesong, Jan; Brennaman, Laura

    2016-01-01

    This study examined nurses' adherence to policies regarding needleless connector changes using a novel, day-of-the-week, color-coded label compared with usual care that relied on electronic medical record (EMR) documentation. This was a prospective, comparative study. The study was performed on 4 medical-surgical units in a seasonally fluctuating, 715-bed healthcare system composed of 2 community hospitals. Convenience sample was composed of adults with central lines hospitalized for 4 or more days. At 4-day intervals, investigators observed bedside label use and EMR needleless connector change documentation. Control patients received standard care-needleless connector change with associated documentation in the EMR. Intervention patients, in addition to standard care, had a day-of-the-week, color-coded label placed on each needleless connector. To account for clustering within unit, multinomial logistic regression models using survey sampling methodology were used to conduct Wald χ tests. A multinominal odds ratio and 95% confidence interval (CI) provided an estimate of using labels that were provided on units relative to usual care documentation of needleless connector change in the EMR. In 335 central line observations, the units with labels (n = 205) had a 321% increase rate of documentation of needleless connector change in the EMR (odds ratio, 4.21; 95% CI, 1.76-10.10; P = .003) compared with the usual care control patients. For units with labels, when labels were present, placement of labels on needleless connectors increased the odds that nurses documented connector changes per policy (4.72; 95% CI, 2.02, 10.98; P = .003). Day-of-the-week, color-coded labels cued nurses to document central line needleless connector change in the EMR, which increased adherence to the needleless connector change policy. Providing day-of-the-week, color-coded needleless connector labels increased EMR documentation of timely needleless connector changes. Timely needleless connector changes may lower the incidence of central line-associated bloodstream infection.

  14. Prospective evaluation of Doppler sonography to detect the twinkling artifact versus unenhanced computed tomography for identifying urinary tract calculi.

    PubMed

    Kielar, Ania Z; Shabana, Wael; Vakili, Maryam; Rubin, Jonathan

    2012-10-01

    The twinkling artifact is an emerging tool for identifying urinary tract calculi. The purpose of this prospective study was to evaluate the diagnostic accuracy of the twinkling artifact compared to unenhanced computed tomography in detecting urolithasis. After Research Ethics Board approval, 51 patients with flank pain from the emergency department were enrolled between November 2009 and September 2010. Patients received an unenhanced computed tomographic scan with 1.25-mm raw data and reformatted 5-mm axial and 2-mm coronal images. Blinded assessment of the urinary tract was performed with gray-scale and color Doppler interrogation. The number of calculi, location, size, kidney distance from the skin, body mass index of the patient, and sonographic image parameters were recorded. There were 35 right-sided and 38 left-sided renal calculi, 14 right-sided and 21 left-sided ureteric calculi, and 6 bladder calculi (total, 114 calculi). Thirteen patients had no calculi. The average calculus size was 2.6 mm (range, 1-9 mm). There were 6 false-positive and 22 false-negative instances of twinkling artifacts. On gray-scale evaluation looking for an echogenic focus with shadowing, there were 8 false-positive and 40 false-negative findings. The positive predictive value (PPV) of the twinkling artifact for identifying calculi was 94%, and the sensitivity was 83%. The PPV of gray-scale sonographic shadowing was only 64.9%, and the sensitivity was 80.2%. The twinkling artifact has a high PPV for detecting renal and urinary tract calculi. Evaluation for the twinkling artifact is a complementary technique to standard gray-scale shadowing of calculi and improves detection of urolithiasis on sonography.

  15. Natural history of vasa previa across gestation using a screening protocol.

    PubMed

    Rebarber, Andrei; Dolin, Cara; Fox, Nathan S; Klauser, Chad K; Saltzman, Daniel H; Roman, Ashley S

    2014-01-01

    The purpose of this study was to estimate the prevalence and persistence rate of vasa previa in at-risk pregnancies using a standardized screening protocol. We conducted a descriptive study of patients with a diagnosis of vasa previa from a single ultrasound unit between June 2005 and June 2012. Vasa previa was defined as a fetal vessel within 2 cm of the internal cervical os on transvaginal sonography. Screening for vasa previa using transvaginal sonography with color flow mapping was performed routinely in the following situations: resolved placenta previa, prior pregnancy with vasa previa, velamentous insertion of the cord in the lower uterine segment, placenta succenturiata in the lower uterine segment, and twin gestations. A total of 27,573 patients were referred to our unit for fetal anatomic surveys over the study period. Thirty-one cases of vasa previa were identified, for an incidence of 1.1 per 1000 pregnancies. Twenty-nine cases had full records available for analysis. Five patients (17.2%) had migration and resolution of the vasa previa. When the diagnosis was made during the second trimester (<26 weeks), there was a 23.8% resolution rate (5 of 21); when the diagnosis was made in the third trimester, none resolved (0 of 8 cases). Of the 24 pregnancies (5 twin gestations and 19 singleton gestations) with persistent vasa previa, there was 100% perinatal survival and a median length of gestation of 35 weeks (range, 27 weeks 5 days-36 weeks 5 days). No known missed cases were identified over the study period. The use of standardized screening for vasa previa based on focused criteria was found to be effective in diagnosing vasa previa, with a 100% survival rate. Vasa previa diagnosed during the second trimester resolves in approximately 25% of cases.

  16. The Upturned Superior Mesenteric Artery Sign for First-Trimester Detection of Congenital Diaphragmatic Hernia and Omphalocele.

    PubMed

    Lakshmy, Ravi Selvaraj; Agnees, Joy; Rose, Nity

    2017-03-01

    The aim of this study was to follow the course of the superior mesenteric artery (SMA) in first-trimester fetuses to predict the location of the small bowel. Its abnormal course aids in early detection of congenital diaphragmatic hernia (CDH) and assessment of the contents of omphalocele. The SMA can be easily identified in a sagittal section of the fetus by using color Doppler sonography at the 11- to 14-week scan, and normally, it has a downward course caudally to supply the intestines. The course of the SMA points to the location of the bowel. We report a series of 7 cases detected in first trimester with an abnormal course of the SMA, 3 of which had CDH and 4 of which had omphalocele. In CDH, the intestines herniate into the thoracic cavity; hence, the SMA tends to have an upward course toward the thorax. In 4 cases of omphalocele, the SMA follows the exteriorized bowel into the base of the umbilical cord. Second-trimester sonography for detection of congenital malformations is a standardized protocol, but a careful anatomic survey at the 11- to 14-week scan is often rewarding. When there is a suspicion of an intrathoracic mass or a mediastinal shift, the upturned course of SMA serves as a valuable sign in confirmation of CDH. Chromosomal abnormalities are often reported in cases of omphalocele containing small bowel only, and the upward course of the SMA toward the base of the cord helps in its early prenatal diagnosis, which facilitates early genetic assessment in these fetuses. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Functional Transcranial Doppler Sonography and a Spatial Orientation Paradigm Identify the Non-Dominant Hemisphere

    ERIC Educational Resources Information Center

    Dorst, J.; Haag, A.; Knake, S.; Oertel, W. H.; Hamer, H. M.; Rosenow, F.

    2008-01-01

    Rationale: Functional transcranial Doppler sonography (fTCD) during word generation is well established for language lateralization. In this study, we evaluated a fTCD paradigm to reliably identify the non-dominant hemisphere. Methods: Twenty-nine right-handed healthy subjects (27.1 [plus or minus] 7.6 years) performed the "cube perspective test"…

  18. Clinical application of a modern high-definition head-mounted display in sonography.

    PubMed

    Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2014-08-01

    Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.

  19. Color-Coded Batteries - Electro-Photonic Inverse Opal Materials for Enhanced Electrochemical Energy Storage and Optically Encoded Diagnostics.

    PubMed

    O'Dwyer, Colm

    2016-07-01

    For consumer electronic devices, long-life, stable, and reasonably fast charging Li-ion batteries with good stable capacities are a necessity. For exciting and important advances in the materials that drive innovations in electrochemical energy storage (EES), modular thin-film solar cells, and wearable, flexible technology of the future, real-time analysis and indication of battery performance and health is crucial. Here, developments in color-coded assessment of battery material performance and diagnostics are described, and a vision for using electro-photonic inverse opal materials and all-optical probes to assess, characterize, and monitor the processes non-destructively in real time are outlined. By structuring any cathode or anode material in the form of a photonic crystal or as a 3D macroporous inverse opal, color-coded "chameleon" battery-strip electrodes may provide an amenable way to distinguish the type of process, the voltage, material and chemical phase changes, remaining capacity, cycle health, and state of charge or discharge of either existing or new materials in Li-ion or emerging alternative battery types, simply by monitoring its color change. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Memory-Context Effects of Screen Color in Multiple-Choice and Fill-In Tests

    ERIC Educational Resources Information Center

    Prestera, Gustavo E.; Clariana, Roy; Peck, Andrew

    2005-01-01

    In this experimental study, 44 undergraduates completed five computer-based instructional lessons and either two multiplechoice tests or two fill-in-the-blank tests. Color-coded borders were displayed during the lesson, adjacent to the screen text and illustrations. In the experimental condition, corresponding border colors were shown at posttest.…

  1. Inclusion of methoxy groups inverts the thermodynamic stabilities of DNA-RNA hybrid duplexes: A molecular dynamics simulation study.

    PubMed

    Suresh, Gorle; Priyakumar, U Deva

    2015-09-01

    Modified nucleic acids have found profound applications in nucleic acid based technologies such as antisense and antiviral therapies. Previous studies on chemically modified nucleic acids have suggested that modifications incorporated in furanose sugar especially at 2'-position attribute special properties to nucleic acids when compared to other modifications. 2'-O-methyl modification to deoxyribose sugars of DNA-RNA hybrids is one such modification that increases nucleic acid stability and has become an attractive class of compounds for potential antisense applications. It has been reported that modification of DNA strands with 2'-O-methyl group reverses the thermodynamic stability of DNA-RNA hybrid duplexes. Molecular dynamics simulations have been performed on two hybrid duplexes (DR and RD) which differ from each other and 2'-O-methyl modified counterparts to investigate the effect of 2'-O-methyl modification on their duplex stability. The results obtained suggest that the modification drives the conformations of both the hybrid duplexes towards A-RNA like conformation. The modified hybrid duplexes exhibit significantly contrasting dynamics and hydration patterns compared to respective parent duplexes. In line with the experimental results, the relative binding free energies suggest that the introduced modifications stabilize the less stable DR hybrid, but destabilize the more stable RD duplex. Binding free energy calculations suggest that the increased hydrophobicity is primarily responsible for the reversal of thermodynamic stability of hybrid duplexes. Free energy component analysis further provides insights into the stability of modified duplexes. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Assembly and analysis of eukaryotic Argonaute–RNA complexes in microRNA-target recognition

    PubMed Central

    Gan, Hin Hark; Gunsalus, Kristin C.

    2015-01-01

    Experimental studies have uncovered a variety of microRNA (miRNA)–target duplex structures that include perfect, imperfect and seedless duplexes. However, non-canonical binding modes from imperfect/seedless duplexes are not well predicted by computational approaches, which rely primarily on sequence and secondary structural features, nor have their tertiary structures been characterized because solved structures to date are limited to near perfect, straight duplexes in Argonautes (Agos). Here, we use structural modeling to examine the role of Ago dynamics in assembling viable eukaryotic miRNA-induced silencing complexes (miRISCs). We show that combinations of low-frequency, global modes of motion of Ago domains are required to accommodate RNA duplexes in model human and C. elegans Ago structures. Models of viable miRISCs imply that Ago adopts variable conformations at distinct target sites that generate distorted, imperfect miRNA-target duplexes. Ago's ability to accommodate a duplex is dependent on the region where structural distortions occur: distortions in solvent-exposed seed and 3′-end regions are less likely to produce steric clashes than those in the central duplex region. Energetic analyses of assembled miRISCs indicate that target recognition is also driven by favorable Ago-duplex interactions. Such structural insights into Ago loading and target recognition mechanisms may provide a more accurate assessment of miRNA function. PMID:26432829

  3. Development of a panel of seven duplex real-time PCR assays for detecting 13 streptococcal superantigens.

    PubMed

    Yang, Peng; Peng, Xiaomin; Cui, Shujuan; Shao, Junbin; Zhu, Xuping; Zhang, Daitao; Liang, Huijie; Wang, Quanyi

    2013-07-30

    Streptococcal superantigens (SAgs) are the major virulence factors of infection in humans for group A Streptococcus (GAS) bacteria. A panel consisting of seven duplex real-time PCR assays was developed to simultaneously detect 13 streptococcal SAgs and one internal control which may be important in the control of GAS-mediated diseases. Primer and probe sequences were selected based on the highly conserved region from an alignment of nucleotide sequences of the 13 streptococcal SAgs. The reaction conditions of the duplex real-time PCR were optimized and the specificity of the duplex assays was evaluated using SAg positive strains. The limit of detection of the duplex assays was determined by using 10-fold serial dilutions of the DNA of 13 streptococcal SAgs and compared to a conventional polymerase chain reaction (PCR) method for evaluating the duplex assays sensitivity. Using the duplex assays, we were able to differentiate between 13 SAgs from Streptococcus strains and other non-Streptococcus bacteria without cross-reaction. On the other hand, the limit of detection of the duplex assays was at least one or two log dilutions lower than that of the conventional PCR. The panel was highly specific (100%) and the limit of detection of these duplex groups was at least ten times lower than that obtained by using a conventional PCR method.

  4. Validation of a novel duplex ultrasound objective structured assessment of technical skills (DUOSATS) for arterial stenosis detection.

    PubMed

    Jaffer, U; Singh, P; Pandey, V A; Aslam, M; Standfield, N J

    2014-01-01

    Duplex ultrasound facilitates bedside diagnosis and hence timely patient care. Its uptake has been hampered by training and accreditation issues. We have developed an assessment tool for Duplex arterial stenosis measurement for both simulator and patient based training. A novel assessment tool: duplex ultrasound assessment of technical skills was developed. A modified duplex ultrasound assessment of technical skills was used for simulator training. Novice, intermediate experience and expert users of duplex ultrasound were invited to participate. Participants viewed an instructional video and were allowed ample time to familiarize with the equipment. Participants' attempts were recorded and independently assessed by four experts using the modified duplex ultrasound assessment of technical skills. 'Global' assessment was also done on a four point Likert scale. Content, construct and concurrent validity as well as reliability were evaluated. Content and construct validity as well as reliability were demonstrated. The simulator had good satisfaction rating from participants: median 4; range 3-5. Receiver operator characteristic analysis has established a cut point of 22/ 34 and 25/ 40 were most appropriate for simulator and patient based assessment respectively. We have validated a novel assessment tool for duplex arterial stenosis detection. Further work is underway to establish transference validity of simulator training to improved skill in scanning patients. We have developed and validated duplex ultrasound assessment of technical skills for simulator training.

  5. Application of remotely sensed multispectral data to automated analysis of marshland vegetation. Inference to the location of breeding habitats of the salt marsh mosquito (Aedes Sollicitans)

    NASA Technical Reports Server (NTRS)

    Cibula, W. G.

    1976-01-01

    The techniques used for the automated classification of marshland vegetation and for the color-coded display of remotely acquired data to facilitate the control of mosquito breeding are presented. A multispectral scanner system and its mode of operation are described, and the computer processing techniques are discussed. The procedures for the selection of calibration sites are explained. Three methods for displaying color-coded classification data are presented.

  6. H-Bond Self-Assembly: Folding versus Duplex Formation.

    PubMed

    Núñez-Villanueva, Diego; Iadevaia, Giulia; Stross, Alexander E; Jinks, Michael A; Swain, Jonathan A; Hunter, Christopher A

    2017-05-17

    Linear oligomers equipped with complementary H-bond donor (D) and acceptor (A) sites can interact via intermolecular H-bonds to form duplexes or fold via intramolecular H-bonds. These competing equilibria have been quantified using NMR titration and dilution experiments for seven systems featuring different recognition sites and backbones. For all seven architectures, duplex formation is observed for homo-sequence 2-mers (AA·DD) where there are no competing folding equilibria. The corresponding hetero-sequence AD 2-mers also form duplexes, but the observed self-association constants are strongly affected by folding equilibria in the monomeric states. When the backbone is flexible (five or more rotatable bonds separating the recognition sites), intramolecular H-bonding is favored, and the folded state is highly populated. For these systems, the stability of the AD·AD duplex is 1-2 orders of magnitude lower than that of the corresponding AA·DD duplex. However, for three architectures which have more rigid backbones (fewer than five rotatable bonds), intramolecular interactions are not observed, and folding does not compete with duplex formation. These systems are promising candidates for the development of longer, mixed-sequence synthetic information molecules that show sequence-selective duplex formation.

  7. 32 CFR 507.5 - Statutory authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... colorable imitations of them, are governed by section 704, title 18, United States Code (18 U.S.C. 704). (b... other designs, prescribed by the head of a U.S. department or agency, or colorable imitations of them...

  8. Color-coded automated signal intensity curves for detection and characterization of breast lesions: preliminary evaluation of a new software package for integrated magnetic resonance-based breast imaging.

    PubMed

    Pediconi, Federica; Catalano, Carlo; Venditti, Fiammetta; Ercolani, Mauro; Carotenuto, Luigi; Padula, Simona; Moriconi, Enrica; Roselli, Antonella; Giacomelli, Laura; Kirchin, Miles A; Passariello, Roberto

    2005-07-01

    The objective of this study was to evaluate the value of a color-coded automated signal intensity curve software package for contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected breast cancer. Thirty-six women with suspected breast cancer based on mammographic and sonographic examinations were preoperatively evaluated on CE-MRM. CE-MRM was performed on a 1.5-T magnet using a 2D Flash dynamic T1-weighted sequence. A dosage of 0.1 mmol/kg of Gd-BOPTA was administered at a flow rate of 2 mL/s followed by 10 mL of saline. Images were analyzed with the new software package and separately with a standard display method. Statistical comparison was performed of the confidence for lesion detection and characterization with the 2 methods and of the diagnostic accuracy for characterization compared with histopathologic findings. At pathology, 54 malignant lesions and 14 benign lesions were evaluated. All 68 (100%) lesions were detected with both methods and good correlation with histopathologic specimens was obtained. Confidence for both detection and characterization was significantly (P < or = 0.025) better with the color-coded method, although no difference (P > 0.05) between the methods was noted in terms of the sensitivity, specificity, and overall accuracy for lesion characterization. Excellent agreement between the 2 methods was noted for both the determination of lesion size (kappa = 0.77) and determination of SI/T curves (kappa = 0.85). The novel color-coded signal intensity curve software allows lesions to be visualized as false color maps that correspond to conventional signal intensity time curves. Detection and characterization of breast lesions with this method is quick and easily interpretable.

  9. Perceptual distortion analysis of color image VQ-based coding

    NASA Astrophysics Data System (ADS)

    Charrier, Christophe; Knoblauch, Kenneth; Cherifi, Hocine

    1997-04-01

    It is generally accepted that a RGB color image can be easily encoded by using a gray-scale compression technique on each of the three color planes. Such an approach, however, fails to take into account correlations existing between color planes and perceptual factors. We evaluated several linear and non-linear color spaces, some introduced by the CIE, compressed with the vector quantization technique for minimum perceptual distortion. To study these distortions, we measured contrast and luminance of the video framebuffer, to precisely control color. We then obtained psychophysical judgements to measure how well these methods work to minimize perceptual distortion in a variety of color space.

  10. Study and simulation of low rate video coding schemes

    NASA Technical Reports Server (NTRS)

    Sayood, Khalid; Chen, Yun-Chung; Kipp, G.

    1992-01-01

    The semiannual report is included. Topics covered include communication, information science, data compression, remote sensing, color mapped images, robust coding scheme for packet video, recursively indexed differential pulse code modulation, image compression technique for use on token ring networks, and joint source/channel coder design.

  11. Optimal patch code design via device characterization

    NASA Astrophysics Data System (ADS)

    Wu, Wencheng; Dalal, Edul N.

    2012-01-01

    In many color measurement applications, such as those for color calibration and profiling, "patch code" has been used successfully for job identification and automation to reduce operator errors. A patch code is similar to a barcode, but is intended primarily for use in measurement devices that cannot read barcodes due to limited spatial resolution, such as spectrophotometers. There is an inherent tradeoff between decoding robustness and the number of code levels available for encoding. Previous methods have attempted to address this tradeoff, but those solutions have been sub-optimal. In this paper, we propose a method to design optimal patch codes via device characterization. The tradeoff between decoding robustness and the number of available code levels is optimized in terms of printing and measurement efforts, and decoding robustness against noises from the printing and measurement devices. Effort is drastically reduced relative to previous methods because print-and-measure is minimized through modeling and the use of existing printer profiles. Decoding robustness is improved by distributing the code levels in CIE Lab space rather than in CMYK space.

  12. N(4)C-ethyl-N(4)C cross-linked DNA: synthesis and characterization of duplexes with interstrand cross-links of different orientations.

    PubMed

    Noronha, Anne M; Noll, David M; Wilds, Christopher J; Miller, Paul S

    2002-01-22

    The preparation and physical properties of short DNA duplexes that contain a N(4)C-ethyl-N(4)C interstrand cross-link are described. Duplexes that contain an interstrand cross-link between mismatched C-C residues and duplexes in which the C residues of a -CG- or -GC- step are linked to give "staggered" interstrand cross-links were prepared using a novel N(4)C-ethyl-N(4)C phosphoramidite reagent. Duplexes with the C-C mismatch cross-link have UV thermal transition temperatures that are 25 degrees C higher than the melting temperatures of control duplexes in which the cross-link is replaced with a G-C base pair. It appears that this cross-link stabilizes adjacent base pairs and does not perturb the structure of the helix, a conclusion that is supported by the CD spectrum of this duplex and by molecular models. An even higher level of stabilization, 49 degrees C, is seen with the duplex that contains a -CG- staggered cross-link. Molecular models suggest that this cross-link may induce propeller twisting in the cross-linked base pairs, and the CD spectrum of this duplex exhibits an unusual negative band at 298 nm, although the remainder of the spectrum is similar to that of B-form DNA. Mismatched C-C or -CG- staggered cross-linked duplexes that have complementary overhanging ends can undergo self-ligation catalyzed by T4 DNA ligase. Analysis of the ligated oligomers by nondenaturing polyacrylamide gel electrophoresis shows that the resulting oligomers migrate in a manner similar to that of a mixture of non-cross-linked control oligomers and suggests that these cross-links do not result in significant bending of the helix. However, the orientation of the staggered cross-link can have a significant effect on the structure and stability of the cross-linked duplex. Thus, the thermal stability of the duplex that contains a -GC- staggered cross-link is 10 degrees C lower than the melting temperature of the control, non-cross-linked duplex. Unlike the -CG- staggered cross-link, in which the cross-linked base pairs can still maintain hydrogen bond contacts, molecular models suggest that formation of the -GC- staggered cross-link disrupts hydrogen bonding and may also perturb adjacent base pairs leading to an overall reduction in helix stability. Duplexes with specifically positioned and oriented cross-links can be used as substrates to study DNA repair mechanisms.

  13. Three-year results after directional atherectomy of calcified stenotic lesions of the superficial femoral artery.

    PubMed

    Minko, P; Buecker, A; Jaeger, S; Katoh, M

    2014-10-01

    To investigate the 3-year outcome of patients with peripheral arterial disease (PAD) and heavily calcified stenotic lesions of the superficial femoral artery after directional atherectomy. Fifty-three patients (mean age 67 ± 10 years; 18 females, 35 males, TASC B and C, mean lesion length 7.9 ± 3.5 cm) with PAD (Rutherford 2-6) were enrolled into this prospective monocentric study. In total, 59 calcified lesions of the superficial femoral artery were treated with the Silverhawk atherectomy device (Covidien, Plymouth, MN, USA). Patients were followed-up for 36 months with a 6-month interval to perform clinical re-evaluation, including measurement of maximum walking distance and ankle-brachial index (ABI) as well as duplex-sonography. The primary success rate of the procedure was 92 %. In five cases (8 %), additional balloon-PTA and/or stent-PTA was necessary. Procedure-related embolization occurred in seven cases (12 %), which were all successfully treated by aspiration. The primary patency rate after 3 years was 55 %. Median Rutherford score decreased significantly from 5 to 0 after 36 months (p < 0.001). At the same time, the ABI increased from 0.65 to 1.12 (not significant). The limb-salvage rate after 3 years was 87 %. In this subgroup of patients with POD and calcified stenotic lesions, atherectomy was successfully applied to decrease the plaque burden. Results after 3 years showed a significant decrease of Rutherford score with persistent improvement of ABI and reasonable patency rate.

  14. Intra- and extracranial atherosclerotic disease in acute spontaneous intracerebral hemorrhage.

    PubMed

    Sato, Shoichiro; Uehara, Toshiyuki; Hayakawa, Mikito; Nagatsuka, Kazuyuki; Minematsu, Kazuo; Toyoda, Kazunori

    2013-09-15

    There is little information about intracranial atherosclerotic disease (ICAD) and extracranial atherosclerotic disease (ECAD) in patients with acute spontaneous intracerebral hemorrhage (ICH). The purpose of the present study was to elucidate the prevalence of and the factors that correlate with ICAD and ECAD in patients with ICH. A total of 274 patients with acute spontaneous ICH were enrolled. ICAD and ECAD (moderate to severe stenosis or occlusion) were mainly assessed by intracranial magnetic resonance angiography and carotid duplex sonography, respectively. Fifty-one patients (19%) had ICAD or ECAD; 32 had ICAD, and 21 had ECAD. On multivariable analyses, age (OR, 1.52; 95% CI, 1.06-2.28 for every 10 years), monocyte count (OR, 1.37; 95% CI, 1.02-1.87 for every 100/mm(3)), hemoglobin A1c (OR, 2.25; 95% CI, 1.08-5.15 for every 1%), and low-density lipoprotein cholesterol levels (OR, 1.23; 95% CI, 1.08-1.42 for every 10mg/dL) were independently associated with ICAD. Age (OR, 2.20; 95% CI, 1.20-4.38 for 10 years) and dyslipidemia (OR, 3.95; 95% CI, 1.01-15.97) were independently associated with ECAD. ICAD and ECAD were detected in approximately one-fifth of patients with spontaneous ICH. Age and dyslipidemia (or lipid profile) were associated with both ICAD and ECAD. Monocyte count and hemoglobin A1c were associated with ICAD. © 2013. Published by Elsevier B.V. All rights reserved.

  15. Prediction and Observation of Post-Admission Hematoma Expansion in Patients with Intracerebral Hemorrhage

    PubMed Central

    Ovesen, Christian; Havsteen, Inger; Rosenbaum, Sverre; Christensen, Hanne

    2014-01-01

    Post-admission hematoma expansion in patients with intracerebral hemorrhage (ICH) comprises a simultaneous major clinical problem and a possible target for medical intervention. In any case, the ability to predict and observe hematoma expansion is of great clinical importance. We review radiological concepts in predicting and observing post-admission hematoma expansion. Hematoma expansion can be observed within the first 24 h after symptom onset, but predominantly occurs in the early hours. Thus capturing markers of on-going bleeding on imaging techniques could predict hematoma expansion. The spot sign observed on computed tomography angiography is believed to represent on-going bleeding and is to date the most well investigated and reliable radiological predictor of hematoma expansion as well as functional outcome and mortality. On non-contrast CT, the presence of foci of hypoattenuation within the hematoma along with the hematoma-size is reported to be predictive of hematoma expansion and outcome. Because patients tend to arrive earlier to the hospital, a larger fraction of acute ICH-patients must be expected to undergo hematoma expansion. This renders observation and radiological follow-up investigations increasingly relevant. Transcranial duplex sonography has in recent years proven to be able to estimate hematoma volume with good precision and could be a valuable tool in bedside serial observation of acute ICH-patients. Future studies will elucidate, if better prediction and observation of post-admission hematoma expansion can help select patients, who will benefit from hemostatic treatment. PMID:25324825

  16. Impact of MCA stenosis on the early outcome in acute ischemic stroke patients

    PubMed Central

    Jeng, Jiann-Shing; Hsieh, Fang-I; Yeh, Hsu-Ling; Chen, Wei-Hung; Chiu, Hou-Chang; Tang, Sung-Chun; Liu, Chung-Hsiang; Lin, Huey-Juan; Hsu, Shih-Pin; Lo, Yuk-Keung; Chan, Lung; Chen, Chih-Hung; Lin, Ruey-Tay; Chen, Yu-Wei; Lee, Jiunn-Tay; Yeh, Chung-Hsin; Sun, Ming-Hui; Lai, Ta-Chang; Sun, Yu; Sun, Mu-Chien; Chen, Po-Lin; Chiang, Tsuey-Ru; Lin, Shinn-Kuang; Yip, Bak-Sau; Chen, Chin-I; Bai, Chi-Huey; Chen, Sien-Tsong; Chiou, Hung-Yi; Lien, Li-Ming; Hsu, Chung Y.

    2017-01-01

    Background Asians have higher frequency of intracranial arterial stenosis. The present study aimed to compare the clinical features and outcomes of ischemic stroke patients with and without middle cerebral artery (MCA) stenosis, assessed by transcranial sonography (TCS), based on the Taiwan Stroke Registry (TSR). Methods Patients with acute ischemic stroke or transient ischemic attack registered in the TSR, and received both carotid duplex and TCS assessment were categorized into those with stenosis (≥50%) and without (<50%) in the extracranial internal carotid artery (ICA) and MCA, respectively. Logistic regression analysis, Kaplan-Meier method and Cox proportional hazard model were applied to assess relevant variables between groups. Results Of 6003 patients, 23.3% had MCA stenosis, 10.1% ICA stenosis, and 3.9% both MCA and ICA stenosis. Patients with MCA stenosis had greater initial NIHSS, higher likelihood of stroke-in-evolution, and more severe disability than those without (all p<0.001). Patients with MCA stenosis had higher prevalence of hypertension, diabetes and hypercholesterolemia. Patients with combined MCA and extracranial ICA stenosis had even higher NIHSS, worse functional outcome, higher risk of stroke recurrence or death (hazard ratio, 2.204; 95% confidence intervals, 1.440–3.374; p<0.001) at 3 months after stroke than those without MCA stenosis. Conclusions In conclusion, MCA stenosis was more prevalent than extracranial ICA stenosis in ischemic stroke patients in Taiwan. Patients with MCA stenosis, especially combined extracranial ICA stenosis, had more severe neurological deficit and worse outcome. PMID:28388675

  17. TRIDIMENSIONAL DOPPLER ASSESSMENT: A RELIABLE, NON-INVASIVE AND COST-EFFECTIVE METHOD FOR PREOPERATIVE PERFORATOR ASSESSMENT IN DIEP FLAP.

    PubMed

    Dražan, L; Lombardo, G A G

    The preoperative perforator mapping is an important step in autologous breast reconstruction, making the flap raising safer, more predictable and time-saving. Although the Doppler exam has proven to be less accurate in locating perforators compared with colour duplex sonography and CTA, it will probably remain of importance in clinical practice. The aim of this paper is to share some advices on how to perform a Doppler exam in preoperative evaluation of a DIEAp flap, increasing its reliability in location of the perforators. The study was carried-out preoperatively on 26 consecutive patients. For the evaluation of the matching between Doppler Dot and operative finding was used a Cartesian coordinate systemResults: We have marked preoperatively 145 perforators in 26 patients for a total of 52 semi-abdomens. An average of 5.6 vessels per patient were marked. Of these, 80 (55.17%) were found between 0-1 cm, 36 (24.82%) between 1-2 cm and 5 (3.4%) of these more than 2 cm from each other. We had 24 (16.55%) false positives in which there was no correspondence between the signal and the intraoperative finding. Although the Doppler exam may not provide the same anatomic details as the other newer modalities, such as CTA and MRA, the HHD remains a very useful and important tool for autologous reconstruction. We recommend performing this exam in our standardized and reproducible method to improve the reliability..

  18. A Prospective, Randomized Trial of Routine Duplex Ultrasound Surveillance on Arteriovenous Fistula Maturation.

    PubMed

    Han, Ahram; Min, Seung-Kee; Kim, Mi-Sook; Joo, Kwon Wook; Kim, Jungsun; Ha, Jongwon; Lee, Joongyub; Min, Sang-Il

    2016-10-07

    Use of arteriovenous fistulas, the most preferred type of access for hemodialysis, is limited by their high maturation failure rate. The aim of this study was to assess whether aggressive surveillance with routine duplex ultrasound and intervention can decrease the maturation failure rate of arteriovenous fistulas. We conducted a single-center, parallel-group, randomized, controlled trial of patients undergoing autogenous arteriovenous fistula. Patients were randomly assigned (1:1) to either the routine duplex or selective duplex group. In the routine duplex group, duplex ultrasound and physical examination were performed 2, 4, and 8 weeks postoperatively. In the selective duplex group, duplex examination was performed only when physical examination detected an abnormality. The primary end point was the maturation failure rate 8 weeks after fistula creation. Maturation failure was defined as the inability to achieve clinical maturation ( i.e. , a successful first use) and failure to achieve sonographic maturation (fistula flow >500 ml/min and diameter >6 mm) within 8 weeks. Between June 14, 2012, and June 25, 2014, 150 patients were enrolled (75 patients in each group), and 118 of those were included in the final analysis. The maturation failure rate was lower in the routine duplex group (8 of 59; 13.6%) than in the selective duplex group (15 of 59; 25.4%), but the difference was not statistically significant (odds ratio, 0.46; 95% confidence interval, 0.18 to 1.19; P =0.10). Factors associated with maturation failure were women (odds ratio, 3.84; 95% confidence interval, 1.05 to 14.06; P =0.04), coronary artery disease (odds ratio, 6.36; 95% confidence interval, 1.62 to 24.95; P <0.01), diabetes (odds ratio, 6.10; 95% confidence interval, 1.76 to 21.19; P <0.01), and the preoperative cephalic vein diameter (odds ratio, 0.30; 95% confidence interval, 0.13 to 0.71; P <0.01). Postoperative routine duplex surveillance failed to prove superiority compared with selective duplex after physical examination for reducing arteriovenous fistula maturation failure. However, the wide 95% confidence interval for the effect of intervention precludes a firm conclusion that routine duplex surveillance was not beneficial. Copyright © 2016 by the American Society of Nephrology.

  19. Thermodynamic and hydration effects for the incorporation of a cationic 3-aminopropyl chain into DNA

    PubMed Central

    Soto, Ana Maria; Kankia, Besik I.; Dande, Prasad; Gold, Barry; Marky, Luis A.

    2002-01-01

    The introduction of cationic 5-(ω-aminoalkyl)-2′-deoxypyrimidines into duplex DNA has been shown to induce DNA bending. In order to understand the energetic and hydration contributions for the incorporation of a cationic side chain in DNA a combination of spectroscopy, calorimetry and density techniques were used. Specifically, the temperature unfolding and isothermal formation was studied for a pair of duplexes with sequence d(CGTAGUCG TGC)/d(GCACGACTACG), where U represents 2′-deoxyuridine (‘control’) or 5-(3-aminopropyl)-2′-deoxyuridine (‘modified’). Continuous variation experiments confirmed 1:1 stoichiometries for each duplex and the circular dichroism spectra show that both duplexes adopted the B conformation. UV and differential scanning calorimetry melting experiments reveal that each duplex unfolds in two-state transitions. In low salt buffer, the ‘modified’ duplex is more stable and unfolds with a lower endothermic heat and lower release of counterion and water. This electrostatic stabilization is entropy driven and disappears at higher salt concentrations. Complete thermodynamic profiles at 15°C show that the favorable formation of each duplex results from the compensation of a favorable exothermic heat with an unfavorable entropy contribution. However, the isothermal profiles yielded a differential enthalpy of 8.8 kcal/mol, which is 4.3 kcal/mol higher than the differential enthalpy observed in the unfolding profiles. This indicates that the presence of the aminopropyl chain induces an increase in base stacking interactions in the modified single strand and a decrease in base stacking interactions in the modified duplex. Furthermore, the formation of the ‘control’ duplex releases water while the ‘modified’ duplex takes up water. Relative to the control duplex, formation of the modified duplex at 15°C yielded a marginal differential ΔG° term, positive ΔΔHITC–Δ(TΔS) compensation, negative ΔΔV and a net release of counterions. The opposite signs of the differential enthalpy–entropy compensation and differential volume change terms show a net uptake of structural water around polar and non-polar groups. This indicates that incorporation of the aminopropyl chain induces a higher exposure of aromatic bases to the solvent, which may be consistent with a small and local bend in the ‘modified’ duplex. PMID:12136099

  20. Benefits of Automatic Duplexing Fact Sheet

    EPA Pesticide Factsheets

    This resource provides a how-to duplex guide, informs the reader on the benefits and cost savings from automatic duplexing, and several off the shelf print management software options for your facility.

  1. Electron Beam Welding of Duplex Steels with using Heat Treatment

    NASA Astrophysics Data System (ADS)

    Schwarz, Ladislav; Vrtochová, Tatiana; Ulrich, Koloman

    2010-01-01

    This contribution presents characteristics, metallurgy and weldability of duplex steels with using concentrated energy source. The first part of the article describes metallurgy of duplex steels and the influence of nitrogen on their solidification. The second part focuses on weldability of duplex steels with using electron beam aimed on acceptable structure and corrosion resistance performed by multiple runs of defocused beam over the penetration weld.

  2. Thyroid Ultrasonography in Differentiation between Graves’ Disease and Hashimoto’s Thyroiditis

    PubMed Central

    Pishdad, P.; Pishdad, G.R.; Tavanaa, S.; Pishdad, R.; Jalli, R.

    2017-01-01

    Objective: Graves’ disease and Hashimoto’s thyroiditis are the most common causes of hyper and hypothyroidism, respectively. Differentiation of these 2 diseases, if the patient is euthyroid, may sometimes be extremely difficult on the basis of clinical and laboratory findings. The purpose of this study was to determine the sensitivity and specificity of gray scale sonography in differentiation of Graves’ disease from Hashimoto’s thyroiditis. Methods: This study included 149 patients divided into three groups, patients with Graves’ disease (34 patients, mean age = 36.8 ± 10.17 years), Patients with Hashimoto’s thyroiditis (62 patients, mean age = 33.4 ± 12.16 years) and control group (53 healthy people, mean age = 34.74 ± 16.87 years). Members of all groups were referred to a single radiologist for thyroid sonography for evaluation of thyroid echogenicity pattern. Results: A total of 117 women and 32 men were examined by sonography. The most common sonographic pattern in Hashimoto and Graves’ was homogenous hypo-echogenicity which was observed in 45.2% and 47.1% of cases, respectively. Peripheral hypo-echogenicity pattern was seen in 40.3% of Hashimoto’s group with 100% specificity and 40.3% sensitivity. Central-hypoechogenic pattern was observed in 17.6% of Graves’ group with 100% and 17.6% specificity and sensitivity, respectively. Conclusion: Our findings indicate that sonography has high specificity but low sensitivity in the diagnosis of either Graves’ disease or Hashimoto’s thyroiditis. It is therefore not possible to differentiate between these two diseases using sonography alone. Confirmation by laboratory data is also needed. PMID:28451576

  3. Evaluation of a color-coded Landsat 5/6 ratio image for mapping lithologic differences in western South Dakota

    USGS Publications Warehouse

    Raines, Gary L.; Bretz, R.F.; Shurr, George W.

    1979-01-01

    From analysis of a color-coded Landsat 5/6 ratio, image, a map of the vegetation density distribution has been produced by Raines of 25,000 sq km of western South Dakota. This 5/6 ratio image is produced digitally calculating the ratios of the bands 5 and 6 of the Landsat data and then color coding these ratios in an image. Bretz and Shurr compared this vegetation density map with published and unpublished data primarily of the U.S. Geological Survey and the South Dakota Geological Survey; good correspondence is seen between this map and existing geologic maps, especially with the soils map. We believe that this Landsat ratio image can be used as a tool to refine existing maps of surficial geology and bedrock, where bedrock is exposed, and to improve mapping accuracy in areas of poor exposure common in South Dakota. In addition, this type of image could be a useful, additional tool in mapping areas that are unmapped.

  4. Ultrasensitive Detection of RNA and DNA Viruses Simultaneously Using Duplex UNDP-PCR Assay

    PubMed Central

    Wang, Zengguo; Zhang, Xiujuan; Zhao, Xiaomin; Du, Qian; Chang, Lingling; Tong, Dewen

    2015-01-01

    Mixed infection of multiple viruses is common in modern intensive pig rearing. However, there are no methods available to detect DNA and RNA viruses in the same reaction system in preclinical level. In this study, we aimed to develop a duplex ultrasensitive nanoparticle DNA probe-based PCR assay (duplex UNDP-PCR) that was able to simultaneously detect DNA and RNA viruses in the same reaction system. PCV2 and TGEV are selected as representatives of the two different types of viruses. PCV2 DNA and TGEV RNA were simultaneously released from the serum sample by boiling with lysis buffer, then magnetic beads and gold nanoparticles coated with single and/or duplex specific probes for TGEV and PCV2 were added to form a sandwich-like complex with nucleic acids released from viruses. After magnetic separation, DNA barcodes specific for PCV2 and TGEV were eluted using DTT and characterized by specific PCR assay for specific DNA barcodes subsequently. The duplex UNDP-PCR showed similar sensitivity as that of single UNDP-PCR and was able to detect 20 copies each of PCV2 and TGEV in the serum, showing approximately 250-fold more sensitivity than conventional duplex PCR/RT-PCR assays. No cross-reaction was observed with other viruses. The positive detection rate of single MMPs- and duplex MMPs-based duplex UNDP-PCR was identical, with 29.6% for PCV2, 9.3% for TGEV and 3.7% for PCV2 and TGEV mixed infection. This duplex UNDP-PCR assay could detect TGEV (RNA virus) and PCV2 (DNA virus) from large-scale serum samples simultaneously without the need for DNA/RNA extraction, purification and reverse transcription of RNA, and showed a significantly increased positive detection rate for PCV2 (29%) and TGEV (11.7%) preclinical infection than conventional duplex PCR/RT-PCR. Therefore, the established duplex UNDP-PCR is a rapid and economical detection method, exhibiting high sensitivity, specificity and reproducibility. PMID:26544710

  5. Ultrasensitive Detection of RNA and DNA Viruses Simultaneously Using Duplex UNDP-PCR Assay.

    PubMed

    Huang, Yong; Xing, Na; Wang, Zengguo; Zhang, Xiujuan; Zhao, Xiaomin; Du, Qian; Chang, Lingling; Tong, Dewen

    2015-01-01

    Mixed infection of multiple viruses is common in modern intensive pig rearing. However, there are no methods available to detect DNA and RNA viruses in the same reaction system in preclinical level. In this study, we aimed to develop a duplex ultrasensitive nanoparticle DNA probe-based PCR assay (duplex UNDP-PCR) that was able to simultaneously detect DNA and RNA viruses in the same reaction system. PCV2 and TGEV are selected as representatives of the two different types of viruses. PCV2 DNA and TGEV RNA were simultaneously released from the serum sample by boiling with lysis buffer, then magnetic beads and gold nanoparticles coated with single and/or duplex specific probes for TGEV and PCV2 were added to form a sandwich-like complex with nucleic acids released from viruses. After magnetic separation, DNA barcodes specific for PCV2 and TGEV were eluted using DTT and characterized by specific PCR assay for specific DNA barcodes subsequently. The duplex UNDP-PCR showed similar sensitivity as that of single UNDP-PCR and was able to detect 20 copies each of PCV2 and TGEV in the serum, showing approximately 250-fold more sensitivity than conventional duplex PCR/RT-PCR assays. No cross-reaction was observed with other viruses. The positive detection rate of single MMPs- and duplex MMPs-based duplex UNDP-PCR was identical, with 29.6% for PCV2, 9.3% for TGEV and 3.7% for PCV2 and TGEV mixed infection. This duplex UNDP-PCR assay could detect TGEV (RNA virus) and PCV2 (DNA virus) from large-scale serum samples simultaneously without the need for DNA/RNA extraction, purification and reverse transcription of RNA, and showed a significantly increased positive detection rate for PCV2 (29%) and TGEV (11.7%) preclinical infection than conventional duplex PCR/RT-PCR. Therefore, the established duplex UNDP-PCR is a rapid and economical detection method, exhibiting high sensitivity, specificity and reproducibility.

  6. Duplex development and abandonment during evolution of the Lewis thrust system, southern Glacier National Park, Montana

    NASA Astrophysics Data System (ADS)

    Yin, An; Kelty, Thomas K.; Davis, Gregory A.

    1989-09-01

    Geologic mapping in southern Glacier National Park, Montana, reveals the presence of two duplexes sharing the same floor thrust fault, the Lewis thrust. The westernmost duplex (Brave Dog Mountain) includes the low-angle Brave Dog roof fault and Elk Mountain imbricate system, and the easternmost (Rising Wolf Mountain) duplex includes the low-angle Rockwell roof fault and Mt. Henry imbricate system. The geometry of these duplexes suggests that they differ from previously described geometric-kinematic models for duplex development. Their low-angle roof faults were preexisting structures that were locally utilized as roof faults during the formation of the imbricate systems. Crosscutting of the Brave Dog fault by the Mt. Henry imbricate system indicates that the two duplexes formed at different times. The younger Rockwell-Mt. Henry duplex developed 20 km east of the older Brave Dog-Elk Mountain duplex; the roof fault of the former is at a higher structural level. Field relations confirm that the low-angle Rockwell fault existed across the southern Glacier Park area prior to localized formation of the Mt. Henry imbricate thrusts beneath it. These thrusts kinematically link the Rockwell and Lewis faults and may be analogous to P shears that form between two synchronously active faults bounding a simple shear system. The abandonment of one duplex and its replacement by another with a new and higher roof fault may have been caused by (1) warping of the older and lower Brave Dog roof fault during the formation of the imbricate system (Elk Mountain) beneath it, (2) an upward shifting of the highest level of a simple shear system in the Lewis plate to a new decollement level in subhorizontal belt strata (= the Rockwell fault) that lay above inclined strata within the first duplex, and (3) a reinitiation of P-shear development (= Mt. Henry imbricate faults) between the Lewis thrust and the subparallel, synkinematic Rockwell fault.

  7. Representing Color Ensembles.

    PubMed

    Chetverikov, Andrey; Campana, Gianluca; Kristjánsson, Árni

    2017-10-01

    Colors are rarely uniform, yet little is known about how people represent color distributions. We introduce a new method for studying color ensembles based on intertrial learning in visual search. Participants looked for an oddly colored diamond among diamonds with colors taken from either uniform or Gaussian color distributions. On test trials, the targets had various distances in feature space from the mean of the preceding distractor color distribution. Targets on test trials therefore served as probes into probabilistic representations of distractor colors. Test-trial response times revealed a striking similarity between the physical distribution of colors and their internal representations. The results demonstrate that the visual system represents color ensembles in a more detailed way than previously thought, coding not only mean and variance but, most surprisingly, the actual shape (uniform or Gaussian) of the distribution of colors in the environment.

  8. Quantitative Analysis of Color Differences within High Contrast, Low Power Reversible Electrophoretic Displays

    DOE PAGES

    Giera, Brian; Bukosky, Scott; Lee, Elaine; ...

    2018-01-23

    Here, quantitative color analysis is performed on videos of high contrast, low power reversible electrophoretic deposition (EPD)-based displays operated under different applied voltages. This analysis is coded in an open-source software, relies on a color differentiation metric, ΔE * 00, derived from digital video, and provides an intuitive relationship between the operating conditions of the devices and their performance. Time-dependent ΔE * 00 color analysis reveals color relaxation behavior, recoverability for different voltage sequences, and operating conditions that can lead to optimal performance.

  9. Quantitative Analysis of Color Differences within High Contrast, Low Power Reversible Electrophoretic Displays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giera, Brian; Bukosky, Scott; Lee, Elaine

    Here, quantitative color analysis is performed on videos of high contrast, low power reversible electrophoretic deposition (EPD)-based displays operated under different applied voltages. This analysis is coded in an open-source software, relies on a color differentiation metric, ΔE * 00, derived from digital video, and provides an intuitive relationship between the operating conditions of the devices and their performance. Time-dependent ΔE * 00 color analysis reveals color relaxation behavior, recoverability for different voltage sequences, and operating conditions that can lead to optimal performance.

  10. Predictive Modeling of Student Performances for Retention and Academic Support in a Diagnostic Medical Sonography Program

    ERIC Educational Resources Information Center

    Borghese, Peter; Lacey, Sandi

    2014-01-01

    As part of a retention and academic support program, data was collected to develop a predictive model of student performances in core classes in a Diagnostic Medical Sonography (DMS) program. The research goal was to identify students likely to have difficulty with coursework and provide supplemental tutorial support. The focus was on the…

  11. 2011 Mississippi Curriculum Framework: Postsecondary Diagnostic Medical Sonography Technology. (Program CIP: 51.0910 - Diagnostic Medical Sonography/Sonographer and Ultrasound)

    ERIC Educational Resources Information Center

    Finch, Wanda; Wilson, Lesa

    2011-01-01

    As the world economy continues to evolve, businesses and industries must adopt new practices and processes in order to survive. Quality and cost control, work teams and participatory management, and an infusion of technology are transforming the way people work and do business. Employees are now expected to read, write, and communicate…

  12. Enhanced dimension-specific visual working memory in grapheme–color synesthesia☆

    PubMed Central

    Terhune, Devin Blair; Wudarczyk, Olga Anna; Kochuparampil, Priya; Cohen Kadosh, Roi

    2013-01-01

    There is emerging evidence that the encoding of visual information and the maintenance of this information in a temporarily accessible state in working memory rely on the same neural mechanisms. A consequence of this overlap is that atypical forms of perception should influence working memory. We examined this by investigating whether having grapheme–color synesthesia, a condition characterized by the involuntary experience of color photisms when reading or representing graphemes, would confer benefits on working memory. Two competing hypotheses propose that superior memory in synesthesia results from information being coded in two information channels (dual-coding) or from superior dimension-specific visual processing (enhanced processing). We discriminated between these hypotheses in three n-back experiments in which controls and synesthetes viewed inducer and non-inducer graphemes and maintained color or grapheme information in working memory. Synesthetes displayed superior color working memory than controls for both grapheme types, whereas the two groups did not differ in grapheme working memory. Further analyses excluded the possibilities of enhanced working memory among synesthetes being due to greater color discrimination, stimulus color familiarity, or bidirectionality. These results reveal enhanced dimension-specific visual working memory in this population and supply further evidence for a close relationship between sensory processing and the maintenance of sensory information in working memory. PMID:23892185

  13. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    PubMed

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  14. Assessment of the facial features and chin development of fetuses with use of serial three-dimensional sonography and the mandibular size monogram in a Chinese population.

    PubMed

    Tsai, Meng-Yin; Lan, Kuo-Chung; Ou, Chia-Yo; Chen, Jen-Huang; Chang, Shiuh-Young; Hsu, Te-Yao

    2004-02-01

    Our purpose was to evaluate whether the application of serial three-dimensional (3D) sonography and the mandibular size monogram can allow observation of dynamic changes in facial features, as well as chin development in utero. The mandibular size monogram has been established through a cross-sectional study involving 183 fetal images. The serial changes of facial features and chin development are assessed in a cohort study involving 40 patients. The monogram reveals that the Biparietal distance (BPD)/Mandibular body length (MBL) ratio is gradually decreased with the advance of gestational age. The cohort study conducted with serial 3D sonography shows the same tendency. Both the images and the results of paired-samples t test (P<.001) statistical analysis suggest that the fetuses develop wider chins and broader facial features in later weeks. The serial 3D sonography and mandibular size monogram display disproportionate growth of the fetal head and chin that leads to changes in facial features in late gestation. This fact must be considered when we evaluate fetuses at risk for development of micrognathia.

  15. Base Pair Opening in a Deoxynucleotide Duplex Containing a cis-syn Thymine Cyclobutane Dimer Lesion

    PubMed Central

    Wenke, Belinda B.; Huiting, Leah N.; Frankel, Elisa B.; Lane, Benjamin F.; Núñez, Megan E.

    2014-01-01

    The cis-syn thymine cyclobutane dimer is a DNA photoproduct implicated in skin cancer. We compared the stability of individual base pairs in thymine dimer-containing duplexes to undamaged parent 10-mer duplexes. UV melting thermodynamic measurements, CD spectroscopy, and 2D NOESY NMR spectroscopy confirm that the thymine dimer lesion is locally and moderately destabilizing within an overall B-form duplex conformation. We measured the rates of exchange of individual imino protons by NMR using magnetization transfer from water and determined the equilibrium constant for the opening of each base pair Kop. In the normal duplex Kop decreases from the frayed ends of the duplex toward the center, such that the central TA pair is the most stable with a Kop of 8×10−7. In contrast, base pair opening at the 5’T of the thymine dimer is facile. The 5’T of the dimer has the largest equilibrium constant (Kop =3×10−4) in its duplex, considerably larger than even the frayed penultimate base pairs. Notably, base pairing by the 3’T of the dimer is much more stable than by the 5’T, indicating that the predominant opening mechanism for the thymine dimer lesion is not likely to be flipping out into solution as a single unit. The dimer asymmetrically affects the stability of the duplex in its vicinity, destabilizing base pairing on its 5’ side more than on the 3’ side. The striking differences in base pair opening between parent and dimer duplexes occur independently of the duplex-single strand melting transitions. PMID:24328089

  16. The Use of Color Cues to Facilitate Discrimination Learning in Moderately Retarded Adults: A Pilot Study.

    ERIC Educational Resources Information Center

    Haese, Julia B.

    1984-01-01

    Twelve moderately retarded adults served as subjects in testing the hypothesis that colored drawings would be more effective in teaching the identification of common kitchen utensils. The study demonstrated that such adults performed better in discrimination tasks with color coding as an aid to developing such living skills as food preparation.…

  17. Hole Transport in A-form DNA/RNA Hybrid Duplexes

    NASA Astrophysics Data System (ADS)

    Wong, Jiun Ru; Shao, Fangwei

    2017-01-01

    DNA/RNA hybrid duplexes are prevalent in many cellular functions and are an attractive target form for electrochemical biosensing and electric nanodevice. However the electronic conductivities of DNA/RNA hybrid duplex remain relatively unexplored and limited further technological applications. Here cyclopropyl-modified deoxyribose- and ribose-adenosines were developed to explore hole transport (HT) in both DNA duplex and DNA/RNA hybrids by probing the transient hole occupancies on adenine tracts. HT yields through both B-form and A-form double helixes displayed similar shallow distance dependence, although the HT yields of DNA/RNA hybrid duplexes were lower than those of DNA duplexes. The lack of oscillatory periods and direction dependence in HT through both helixes implied efficient hole propagation can be achieved via the hole delocalization and coherent HT over adenine tracts, regardless of the structural variations.

  18. Hole Transport in A-form DNA/RNA Hybrid Duplexes

    PubMed Central

    Wong, Jiun Ru; Shao, Fangwei

    2017-01-01

    DNA/RNA hybrid duplexes are prevalent in many cellular functions and are an attractive target form for electrochemical biosensing and electric nanodevice. However the electronic conductivities of DNA/RNA hybrid duplex remain relatively unexplored and limited further technological applications. Here cyclopropyl-modified deoxyribose- and ribose-adenosines were developed to explore hole transport (HT) in both DNA duplex and DNA/RNA hybrids by probing the transient hole occupancies on adenine tracts. HT yields through both B-form and A-form double helixes displayed similar shallow distance dependence, although the HT yields of DNA/RNA hybrid duplexes were lower than those of DNA duplexes. The lack of oscillatory periods and direction dependence in HT through both helixes implied efficient hole propagation can be achieved via the hole delocalization and coherent HT over adenine tracts, regardless of the structural variations. PMID:28084308

  19. Development of duplex RT-PCR-ELISA for the simultaneous detection of hepatitis A virus and hepatitis E virus.

    PubMed

    Tahk, Hongmin; Lee, Min Hwa; Lee, Kang Bum; Cheon, Doo-Sung; Choi, Changsun

    2011-07-01

    This study aimed to develop a specific and sensitive duplex reverse transcription polymerase chain reaction enzyme-linked immunosorbent assay (duplex RT-PCR-ELISA) for hepatitis A virus (HAV) and hepatitis E virus (HEV). Duplex RT-PCR-ELISA could detect and differentiate HAV and HEV with specific probes. When ELISA technique was used to detect probe-bound RT-PCR products, duplex RT-PCR-ELISA could detect as little as 0.1 ng/μL HAV and HEV from clinical samples. Human norovirus, enterovirus, poliovirus, murine norovirus and feline calicivirus were used for the specificity test; all were negative. Therefore duplex RT-PCR-ELISA can be used for the simultaneous detection of HAV and HEV in contaminated fecal samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Development of a mobile satellite communication unit

    NASA Technical Reports Server (NTRS)

    Suzuki, Ryutaro; Ikegami, Tetsushi; Hamamoto, Naokazu; Taguchi, Tetsu; Endo, Nobuhiro; Yamamoto, Osamu; Ichiyoshi, Osamu

    1988-01-01

    A compact 210(W) x 280(H) x 330(D) mm mobile terminal capable of transmitting voice and data through L-band mobile satellites is described. The Voice Codec can convert an analog voice to or from digital codes at rates of 9.6, 8 and 4.8 kb/s by an MPC algorithm. The terminal functions with a single 12 V power supplied vehicle battery. The equipment can operate at any L-band frequency allocated for mobile uses in a full duplex mode and will soon be put into a field test via Japans's ETS-V satellite.

  1. Thermal effects of diagnostic ultrasound in an anthropomorphic skull model.

    PubMed

    Vyskocil, E; Pfaffenberger, S; Kollmann, C; Gleiss, A; Nawratil, G; Kastl, S; Unger, E; Aumayr, K; Schuhfried, O; Huber, K; Wojta, J; Gottsauner-Wolf, M

    2012-12-01

    Exposure to diagnostic ultrasound (US) can significantly heat biological tissue although conventional routine examinations are regarded as safe. The risk of unwanted thermal effects increases with a high absorption coefficient and extended insonation time. Certain applications of transcranial diagnostic US (TC-US) require prolonged exposure. An anthropomorphic skull model (ASM) was developed to evaluate thermal effects induced by TC-US of different modalities. The objective was to determine whether prolonged continuous TC-US application results in potentially harmful temperature increases. The ASM consists of a human skull with tissue mimicking material and exhibits acoustic and anatomical characteristics of the human skull and brain. Experiments are performed with a diagnostic US device testing four different US modalities: Duplex PW (pulsed wave) Doppler, PW Doppler, color flow Doppler and B-mode. Temperature changes are recorded during 180 minutes of insonation. All measurements revealed significant temperature increases during insonation independent of the US modality. The maximum temperature elevation of + 5.25° C (p < 0.001) was observed on the surface of the skull exposed to duplex PW Doppler. At the bone-brain border a maximum temperature increae of + 2.01 °C (p < 0.001) was noted. Temperature increases within the brain were < 1.23 °C (p = 0.001). The highest values were registered using the duplex PW Doppler modality. TC-US induces significant local heating effects in an ASM. An application duration that extends routine clinical periods causes potentially harmful heating especially in tissue close to bone. TC-US elevates the temperature in the brain mimicking tissue but is not capable of producing harmful temperature increases during routine examinations. However, the risk of thermal injury in brain tissue increases significantly after an exposure time of > 2 hours. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Oxidation characteristics of porous-nickel prepared by powder metallurgy and cast-nickel at 1273 K in air for total oxidation time of 100 h.

    PubMed

    Mohamed, Lamiaa Z; Ghanem, Wafaa A; El Kady, Omayma A; Lotfy, Mohamed M; Ahmed, Hafiz A; Elrefaie, Fawzi A

    2017-11-01

    The oxidation behavior of two types of inhomogeneous nickel was investigated in air at 1273 K for a total oxidation time of 100 h. The two types were porous sintered-nickel and microstructurally inhomogeneous cast-nickel. The porous-nickel samples were fabricated by compacting Ni powder followed by sintering in vacuum at 1473 K for 2 h. The oxidation kinetics of the samples was determined gravimetrically. The topography and the cross-section microstructure of each oxidized sample were observed using optical and scanning electron microscopy. X-ray diffractometry and X-ray energy dispersive analysis were used to determine the nature of the formed oxide phases. The kinetic results revealed that the porous-nickel samples had higher trend for irreproducibility. The average oxidation rate for porous- and cast-nickel samples was initially rapid, and then decreased gradually to become linear. Linear rate constants were 5.5 × 10 -8  g/cm 2  s and 3.4 × 10 -8  g/cm 2  s for the porous- and cast-nickel samples, respectively. Initially a single-porous non-adherent NiO layer was noticed on the porous- and cast-nickel samples. After a longer time of oxidation, a non-adherent duplex NiO scale was formed. The two layers of the duplex scales were different in color. NiO particles were observed in most of the pores of the porous-nickel samples. Finally, the linear oxidation kinetics and the formation of porous non-adherent duplex oxide scales on the inhomogeneous nickel substrates demonstrated that the addition of new layers of NiO occurred at the scale/metal interface due to the thermodynamically possible reaction between Ni and the molecular oxygen migrating inwardly.

  3. Color differences among feral pigeons (Columba livia) are not attributable to sequence variation in the coding region of the melanocortin-1 receptor gene (MC1R)

    PubMed Central

    2013-01-01

    Background Genetic variation at the melanocortin-1 receptor (MC1R) gene is correlated with melanin color variation in many birds. Feral pigeons (Columba livia) show two major melanin-based colorations: a red coloration due to pheomelanic pigment and a black coloration due to eumelanic pigment. Furthermore, within each color type, feral pigeons display continuous variation in the amount of melanin pigment present in the feathers, with individuals varying from pure white to a full dark melanic color. Coloration is highly heritable and it has been suggested that it is under natural or sexual selection, or both. Our objective was to investigate whether MC1R allelic variants are associated with plumage color in feral pigeons. Findings We sequenced 888 bp of the coding sequence of MC1R among pigeons varying both in the type, eumelanin or pheomelanin, and the amount of melanin in their feathers. We detected 10 non-synonymous substitutions and 2 synonymous substitution but none of them were associated with a plumage type. It remains possible that non-synonymous substitutions that influence coloration are present in the short MC1R fragment that we did not sequence but this seems unlikely because we analyzed the entire functionally important region of the gene. Conclusions Our results show that color differences among feral pigeons are probably not attributable to amino acid variation at the MC1R locus. Therefore, variation in regulatory regions of MC1R or variation in other genes may be responsible for the color polymorphism of feral pigeons. PMID:23915680

  4. Cy3 and Cy5 dyes attached to oligonucleotide terminus stabilize DNA duplexes: predictive thermodynamic model.

    PubMed

    Moreira, Bernardo G; You, Yong; Owczarzy, Richard

    2015-03-01

    Cyanine dyes are important chemical modifications of oligonucleotides exhibiting intensive and stable fluorescence at visible light wavelengths. When Cy3 or Cy5 dye is attached to 5' end of a DNA duplex, the dye stacks on the terminal base pair and stabilizes the duplex. Using optical melting experiments, we have determined thermodynamic parameters that can predict the effects of the dyes on duplex stability quantitatively (ΔG°, Tm). Both Cy dyes enhance duplex formation by 1.2 kcal/mol on average, however, this Gibbs energy contribution is sequence-dependent. If the Cy5 is attached to a pyrimidine nucleotide of pyrimidine-purine base pair, the stabilization is larger compared to the attachment to a purine nucleotide. This is likely due to increased stacking interactions of the dye to the purine of the complementary strand. Dangling (unpaired) nucleotides at duplex terminus are also known to enhance duplex stability. Stabilization originated from the Cy dyes is significantly larger than the stabilization due to the presence of dangling nucleotides. If both the dangling base and Cy3 are present, their thermodynamic contributions are approximately additive. New thermodynamic parameters improve predictions of duplex folding, which will help design oligonucleotide sequences for biophysical, biological, engineering, and nanotechnology applications. Copyright © 2015. Published by Elsevier B.V.

  5. An Autonomous Satellite Time Synchronization System Using Remotely Disciplined VC-OCXOs

    PubMed Central

    Gu, Xiaobo; Chang, Qing; Glennon, Eamonn P.; Xu, Baoda; Dempseter, Andrew G.; Wang, Dun; Wu, Jiapeng

    2015-01-01

    An autonomous remote clock control system is proposed to provide time synchronization and frequency syntonization for satellite to satellite or ground to satellite time transfer, with the system comprising on-board voltage controlled oven controlled crystal oscillators (VC-OCXOs) that are disciplined to a remote master atomic clock or oscillator. The synchronization loop aims to provide autonomous operation over extended periods, be widely applicable to a variety of scenarios and robust. A new architecture comprising the use of frequency division duplex (FDD), synchronous time division (STDD) duplex and code division multiple access (CDMA) with a centralized topology is employed. This new design utilizes dual one-way ranging methods to precisely measure the clock error, adopts least square (LS) methods to predict the clock error and employs a third-order phase lock loop (PLL) to generate the voltage control signal. A general functional model for this system is proposed and the error sources and delays that affect the time synchronization are discussed. Related algorithms for estimating and correcting these errors are also proposed. The performance of the proposed system is simulated and guidance for selecting the clock is provided. PMID:26213929

  6. Nanopore Analysis of the 5-Guanidinohydantoin to Iminoallantoin Isomerization in Duplex DNA.

    PubMed

    Zeng, Tao; Fleming, Aaron M; Ding, Yun; Ren, Hang; White, Henry S; Burrows, Cynthia J

    2018-04-06

    In DNA, guanine oxidation yields diastereomers of 5-guanidinohydantoin (Gh) as one of the major products. In nucleosides and single-stranded DNA, Gh is in a pH-dependent equilibrium with its constitutional isomer iminoallantoin (Ia). Herein, the isomerization reaction between Gh and Ia was monitored in duplex DNA using a protein nanopore by measuring the ionic current when duplex DNA interacts with the pore under an electrophoretic force. Monitoring current levels in this single-molecule method proved to be superior for analysis of population distributions in an equilibrating mixture of four isomers in duplex DNA as a function of pH. The results identified Gh as a major isomer observed when base paired with A, C, or G at pH 6.4-8.4, and Ia was a minor isomer of the reaction mixture that was only observed when the pH was >7.4 in the duplex DNA context. The present results suggest that Gh will be the dominant isomer in duplex DNA under physiological conditions regardless of the base-pairing partner in the duplex.

  7. Reducing the background fluorescence in mice receiving fluorophore/inhibitor DNA duplexes.

    PubMed

    Liang, Minmin; Liu, Xinrong; Liu, Guozheng; Dou, Shuping; Cheng, Dengfeng; Liu, Yuxia; Rusckowski, Mary; Hnatowich, Donald J

    2011-02-07

    In principle, a DNA duplex consisting of an antisense fluorophore-conjugated major strand hybridized to a shorter complementary inhibitor-conjugated minor strand should provide fluorescence only in the tumor after intravenous administration if designed to remain intact except in the presence in tumor of its mRNA target. While we have obtained impressive tumor images in mice using this approach, there remains some background fluorescence. In this study, tissue homogenates of selected mouse organs were incubated with a test duplex and the kinetics of duplex dissociation in normal tissues were measured. In this manner we were able to identify the liver as the likely major source responsible for the duplex dissociation providing this fluorescence background. Thereafter liver homogenates were used to screen a series of duplex candidates with variable-length minor strands, and dissociation was measured by gel electrophoresis. The selected fluorophore/inhibitor duplex with improved stability displayed an insignificant (P > 0.05) background fluorescence after administration to SKH-1 normal mice and apparently without affecting target mRNA binding in vitro in cell culture or in vivo in tumor bearing mice.

  8. Synthesis of 5-(1,2,3-triazol-4-yl)-2'-deoxyuridines by a click chemistry approach: stacking of triazoles in the major groove gives increased nucleic acid duplex stability.

    PubMed

    Kocalka, Petr; Andersen, Nicolai K; Jensen, Frank; Nielsen, Poul

    2007-11-23

    A general protocol for converting alkyl and aryl halides into azides and for converting these in situ into 1,4-disubstituted triazoles was applied with 5-ethynyl-2'-deoxyuridine. This afforded three modified 2'-deoxyuridine analogues with either unsubstituted or 1-phenyl-/1-benzyl-substituted triazoles in their 5-positions. Modelling demonstrates coplanarity of the two heteroaromatic rings, and UV spectroscopy showed the uracil pK(a) values to be almost unchanged. The three nucleosides were introduced into nonamer oligonucleotides by phosphoramidite chemistry. The heteroaromatic triazoles became positioned in the major grooves of the short dsDNA and DNA-RNA duplexes. While single modifications led to decreased duplex stability, the stacking of four consecutive modifications led to enhanced duplex stability, especially for DNA-RNA duplexes. The duplex structures were studied by CD spectroscopy and molecular dynamics simulations, which supported the conjecture that the duplex stabilizing effect is due to efficient stacking of the heteroaromatic triazoles.

  9. False Color Terrain Model of Phoenix Workspace

    NASA Image and Video Library

    2008-05-28

    This is a terrain model of Phoenix Robotic Arm workspace. It has been color coded by depth with a lander model for context. The model has been derived using images from the depth perception feature from Phoenix Surface Stereo Imager SSI.

  10. Derivatization of DNAs with Selenium at 6-Position of Guanine for Function and Crystal Structure Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salon, J.; Jiang, J; Sheng, J

    2008-01-01

    To investigate nucleic acid base pairing and stacking via atom-specific mutagenesis and crystallography, we have synthesized for the first time the 6-Se-deoxyguanosine phosphoramidite and incorporated it into DNAs via solid-phase synthesis with a coupling yield over 97%. We found that the UV absorption of the Se-DNAs red-shifts over 100 nm to 360 nm ({Epsilon} = 2.3 x 10{sup 4} M{sup -1} cm{sup -1}), the Se-DNAs are yellow colored, and this Se modification is relatively stable in water and at elevated temperature. Moreover, we successfully crystallized a ternary complex of the Se-G-DNA, RNA and RNase H. The crystal structure determination andmore » analysis reveal that the overall structures of the native and Se-modified nucleic acid duplexes are very similar, the selenium atom participates in a Se-mediated hydrogen bond (Se H-N), and the {sup Se}G and C form a base pair similar to the natural G-C pair though the Se-modification causes the base-pair to shift (approximately 0.3 {angstrom}). Our biophysical and structural studies provide new insights into the nucleic acid flexibility, duplex recognition and stability. Furthermore, this novel selenium modification of nucleic acids can be used to investigate chemogenetics and structure of nucleic acids and their protein complexes.« less

  11. Asymptomatic cervicocerebral atherosclerosis, intracranial vascular resistance and cognition: the AsIA-neuropsychology study.

    PubMed

    López-Olóriz, Jorge; López-Cancio, Elena; Arenillas, Juan F; Hernández, María; Jiménez, Marta; Dorado, Laura; Barrios, Maite; Soriano-Raya, Juan José; Miralbell, Júlia; Cáceres, Cynthia; Forés, Rosa; Pera, Guillem; Dávalos, Antoni; Mataró, Maria

    2013-10-01

    Carotid atherosclerosis has emerged as a relevant contributor to cognitive impairment and dementia whereas the role of intracranial stenosis and vascular resistance in cognition remains unknown. This study aims to assess the association of asymptomatic cervicocerebral atherosclerosis and intracranial vascular resistance with cognitive performance in a large dementia-free population. The Barcelona-AsIA (Asymptomatic Intracranial Atherosclerosis) Neuropsychology Study included 747 Caucasian subjects older than 50 with a moderate-high vascular risk (assessed by REGICOR score) and without history of neither symptomatic vascular disease nor dementia. Extracranial and transcranial color-coded duplex ultrasound examination was performed to assess carotid intima-media thickness (IMT), presence of carotid plaques (ECAD group), intracranial stenosis (ICAD group), and middle cerebral artery pulsatility index (MCA-PI) as a measure of intracranial vascular resistance. Neuropsychological assessment included tests in three cognitive domains: visuospatial skills and speed, verbal memory and verbal fluency. In univariate analyses, carotid IMT, ECAD and MCA-PI were associated with lower performance in almost all cognitive domains, and ICAD was associated with poor performance in some visuospatial and verbal cognitive tests. After adjustment for age, sex, vascular risk score, years of education and depressive symptoms, ECAD remained associated with poor performance in the three cognitive domains and elevated MCA-PI with worse performance in visuospatial skills and speed. Carotid plaques and increased intracranial vascular resistance are independently associated with low cognitive functioning in Caucasian stroke and dementia-free subjects. We failed to find an independent association of intracranial large vessel stenosis with cognitive performance. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Improving the molecular diagnosis of Chlamydia psittaci and Chlamydia abortus infection with a species-specific duplex real-time PCR.

    PubMed

    Opota, Onya; Jaton, Katia; Branley, James; Vanrompay, Daisy; Erard, Veronique; Borel, Nicole; Longbottom, David; Greub, Gilbert

    2015-10-01

    Chlamydia psittaci and Chlamydia abortus are closely related intracellular bacteria exhibiting different tissue tropism that may cause severe but distinct infection in humans. C. psittaci causes psittacosis, a respiratory zoonotic infection transmitted by birds. C. abortus is an abortigenic agent in small ruminants, which can also colonize the human placenta and lead to foetal death and miscarriage. Infections caused by C. psittaci and C. abortus are underestimated mainly due to diagnosis difficulties resulting from their strict intracellular growth. We developed a duplex real-time PCR to detect and distinguish these two bacteria in clinical samples. The first PCR (PCR1) targeted a sequence of the 16S-23S rRNA operon allowing the detection of both C. psittaci and C. abortus. The second PCR (PCR2) targeted the coding DNA sequence CPSIT_0607 unique to C. psittaci. The two PCRs showed 100 % detection for ≥ 10 DNA copies per reaction (1000 copies ml(- 1)). Using a set of 120 samples, including bacterial reference strains, clinical specimens and infected cell culture material, we monitored 100 % sensitivity and 100 % specificity for the detection of C. psittaci and C. abortus for PCR1. When PCR1 was positive, PCR2 could discriminate C. psittaci from C. abortus with a positive predictive value of 100 % and a negative predictive value of 88 %. In conclusion, this new duplex PCR represents a low-cost and time-saving method with high-throughput potential, expected to improve the routine diagnosis of psittacosis and pregnancy complication in large-scale screening programs and also during outbreaks.

  13. 50 years of DNA ‘Breathing’: Reflections on Old and New Approaches

    PubMed Central

    von Hippel, Peter H.; Johnson, Neil P.; Marcus, Andrew H.

    2015-01-01

    Summary The coding sequences for genes, and much other regulatory information involved in genome expression, are located ‘inside’ the DNA duplex. Thus the ‘macromolecular machines’ that read-out this information from the base sequence of the DNA must somehow access the DNA ‘interior’. Double-stranded (ds) DNA is a highly structured and cooperatively stabilized system at physiological temperatures, but is also only marginally stable and undergoes a cooperative ‘melting phase transition’ at temperatures not far above physiological. Furthermore, due to its length and heterogeneous sequence, with AT-rich segments being less stable than GC-rich segments, the DNA genome ‘melts’ in a multistate fashion. Therefore the DNA genome must also manifest thermally driven structural (‘breathing’) fluctuations at physiological temperatures that should reflect the heterogeneity of the dsDNA stability near the melting temperature. Thus many of the breathing fluctuations of dsDNA are likely also to be sequence dependent, and could well contain information that should be ‘readable’ and useable by regulatory proteins and protein complexes in site-specific binding reactions involving dsDNA ‘opening’. Our laboratory has been involved in studying the breathing fluctuations of duplex DNA for about 50 years. In this ‘Reflections’ article we present a relatively chronological overview of these studies, starting with the use of simple chemical probes (such as hydrogen exchange, formaldehyde and simple DNA ‘melting’ proteins) to examine the local stability of the dsDNA structure, and culminating in sophisticated spectroscopic approaches that can be used to monitor the breathing-dependent interactions of regulatory complexes with their duplex DNA targets in ‘real time’. PMID:23840028

  14. Synthesis of native-like crosslinked duplex RNA and study of its properties.

    PubMed

    Onizuka, Kazumitsu; Hazemi, Madoka E; Thomas, Justin M; Monteleone, Leanna R; Yamada, Ken; Imoto, Shuhei; Beal, Peter A; Nagatsugi, Fumi

    2017-04-01

    A variety of enzymes have been found to interact with double-stranded RNA (dsRNA) in order to carry out its functions. We have endeavored to prepare the covalently crosslinked native-like duplex RNA, which could be useful for biochemical studies and RNA nanotechnology. In this study, the interstrand covalently linked duplex RNA was formed by a crosslinking reaction between vinylpurine (VP) and the target cytosine or uracil in RNA. We measured melting temperatures and CD spectra to identify the properties of the VP crosslinked duplex RNA. The crosslinking formation increased the thermodynamic stability without disturbing the natural conformation of dsRNA. In addition, a competitive binding experiment with the duplex RNA binding enzyme, ADAR2, showed the crosslinked dsRNA bound the protein with nearly the same binding affinity as the natural dsRNA, confirming that it has finely preserved the natural traits of duplex RNA. Copyright © 2017. Published by Elsevier Ltd.

  15. 'Passive-roof' duplex geometry in the frontal structures of the Kirthar and Sulaiman mountain belts, Pakistan

    NASA Astrophysics Data System (ADS)

    Banks, C. J.; Warburton, J.

    Exploration for hydrocarbons over the past few years has greatly improved our understanding of the geometry of frontal mountain belt structures. In this study we introduce and discuss the concept of the 'Passive-roof duplex', using as the main example the Kirthar and Sulaiman Ranges in the Baluchistan Province of Pakistan. Structures similar to those described here have been recognized previously in other mountain belts, and they appear to exist as a common feature in many more frontal regions of mountain belts. Our example of a Passive-roof duplex which we describe from Pakistan is compared briefly with similar structures reported by others. The Passive-roof duplex is here defined as a duplex whose roof thrust has backthrust sense ( Passive-roof thrust) and whose roof sequence (those rocks lying above the roof thrust) remains relatively 'stationary' during foreland directed piggy-back style propagation of horses within the duplex.

  16. Enzymatic Reaction with Unnatural Substrates: DNA Photolyase (Escherichia coli) Recognizes and Reverses Thymine [2+2] Dimers in the DNA Strand of a DNA/PNA Hybrid Duplex

    NASA Astrophysics Data System (ADS)

    Ramaiah, Danaboyina; Kan, Yongzhi; Koch, Troels; Orum, Henrik; Schuster, Gary B.

    1998-10-01

    Peptide nucleic acids (PNA) are mimics with normal bases connected to a pseudopeptide chain that obey Watson--Crick rules to form stable duplexes with itself and natural nucleic acids. This has focused attention on PNA as therapeutic or diagnostic reagents. Duplexes formed with PNA mirror some but not all properties of DNA. One fascinating aspect of PNA biochemistry is their reaction with enzymes. Here we show an enzyme reaction that operates effectively on a PNA/DNA hybrid duplex. A DNA oligonucleotide containing a cis, syn-thymine [2+2] dimer forms a stable duplex with PNA. The hybrid duplex is recognized by photolyase, and irradiation of the complex leads to the repair of the thymine dimer. This finding provides insight into the enzyme mechanism and provides a means for the selective repair of thymine photodimers.

  17. 2007 Mississippi Curriculum Framework: Postsecondary Diagnostic Medical Sonography Technology. (Program CIP: 51.0910 - Diagnostic Medical Sonography/Sonographer and Ultrasound Technician)

    ERIC Educational Resources Information Center

    Larimore, Crystal; Megginson, Nita; Weekley, Tracy B.

    2007-01-01

    As the world economy continues to evolve, businesses and industries must adopt new practices and processes in order to survive. Quality and cost control, work teams and participatory management, and an infusion of technology are transforming the way people work and do business. Employees are now expected to read, write, and communicate…

  18. Impact of Duplex arterial mapping on decision making in non-acute ischemic limb patients.

    PubMed

    Elbadawy, A; Aly, H; Ibrahim, M; Bakr, H

    2015-12-01

    The aim of this study was to demonstrate the impact of Duplex arterial mapping on decision making in non-acute ischemic limb patient group reporting pain onset between 15 days and 3 months. We prospectively evaluated patients presented with critical limb ischemia who reported pain onset of duration between 15 days and 3 months in one-year period. Our series included thirty cases (mean age=61.3 years old), as Duplex arterial mapping was the sole preoperative imaging tool performed in all of them. All patients, in whom duplex indicated thrombosis in long occluded segments, were candidates for fluoroscopically guided thrombectomy. When Duplex defined chronic arterial occlusions, patients underwent endovascular or bypass revascularisation procedures. Impact of Duplex wall interrogation on decision-making between the two groups (subacute and chronic) was measured. Duplex arterial mapping categorized correctly all 30 patients into either subacute ischemia with removable clot (N.=14) or chronic ischemia (N.=16). Fluoroscopic guided thrombectomy was performed in 14 cases when Duplex advised long occluded arterial segments as indicted by intact intima with echogenic thrombus inside. Bypass surgery was performed in 8 patients. Percutaneous transluminal angioplasty (PTA) was done in 7 cases and thrombendartrectomy of common femoral artery in a single case. One-year patency rate in our series was 86.6%. It was 71.4% in thrombosis group. Limb salvage rate was 93.3%. Duplex arterial mapping could be used to differentiate the subacute ischemia with removable thrombus and chronic arterial occlusions guiding for the best revascularization procedure accordingly.

  19. Development and properties of duplex MgF2/PCL coatings on biodegradable magnesium alloy for biomedical applications.

    PubMed

    Makkar, Preeti; Kang, Hoe Jin; Padalhin, Andrew R; Park, Ihho; Moon, Byoung-Gi; Lee, Byong Taek

    2018-01-01

    The present work addresses the performance of polycaprolactone (PCL) coating on fluoride treated (MgF2) biodegradable ZK60 magnesium alloy (Mg) for biomedical application. MgF2 conversion layer was first produced by immersing Mg alloy substrate in hydrofluoric acid solution. The outer PCL coating was then prepared using dip coating technique. Morphology, elements profile, phase structure, roughness, mechanical properties, invitro corrosion, and biocompatibility of duplex MgF2/PCL coating were then characterized and compared to those of fluoride coated and uncoated Mg samples. The invivo degradation behavior and biocompatibility of duplex MgF2/PCL coating with respect to ZK60 Mg alloy were also studied using rabbit model for 2 weeks. SEM and TEM analysis showed that the duplex coating was uniform and comprised of porous PCL film (~3.3 μm) as upper layer with compact MgF2 (~2.2 μm) as inner layer. No significant change in microhardness was found on duplex coating compared with uncoated ZK60 Mg alloy. The duplex coating showed improved invitro corrosion resistance than single layered MgF2 or uncoated alloy samples. The duplex coating also resulted in better cell viability, cell adhesion, and cell proliferation compared to fluoride coated or uncoated alloy. Preliminary invivo studies indicated that duplex MgF2/PCL coating reduced the degradation rate of ZK60 Mg alloy and exhibited good biocompatibility. These results suggested that duplex MgF2/PCL coating on magnesium alloy might have great potential for orthopedic applications.

  20. Development and properties of duplex MgF2/PCL coatings on biodegradable magnesium alloy for biomedical applications

    PubMed Central

    Makkar, Preeti; Kang, Hoe Jin; Padalhin, Andrew R.; Park, Ihho; Moon, Byoung-Gi

    2018-01-01

    The present work addresses the performance of polycaprolactone (PCL) coating on fluoride treated (MgF2) biodegradable ZK60 magnesium alloy (Mg) for biomedical application. MgF2 conversion layer was first produced by immersing Mg alloy substrate in hydrofluoric acid solution. The outer PCL coating was then prepared using dip coating technique. Morphology, elements profile, phase structure, roughness, mechanical properties, invitro corrosion, and biocompatibility of duplex MgF2/PCL coating were then characterized and compared to those of fluoride coated and uncoated Mg samples. The invivo degradation behavior and biocompatibility of duplex MgF2/PCL coating with respect to ZK60 Mg alloy were also studied using rabbit model for 2 weeks. SEM and TEM analysis showed that the duplex coating was uniform and comprised of porous PCL film (~3.3 μm) as upper layer with compact MgF2 (~2.2 μm) as inner layer. No significant change in microhardness was found on duplex coating compared with uncoated ZK60 Mg alloy. The duplex coating showed improved invitro corrosion resistance than single layered MgF2 or uncoated alloy samples. The duplex coating also resulted in better cell viability, cell adhesion, and cell proliferation compared to fluoride coated or uncoated alloy. Preliminary invivo studies indicated that duplex MgF2/PCL coating reduced the degradation rate of ZK60 Mg alloy and exhibited good biocompatibility. These results suggested that duplex MgF2/PCL coating on magnesium alloy might have great potential for orthopedic applications. PMID:29608572

  1. Terrorism-related fear and avoidance behavior in a multiethnic urban population.

    PubMed

    Eisenman, David P; Glik, Deborah; Ong, Michael; Zhou, Qiong; Tseng, Chi-Hong; Long, Anna; Fielding, Jonathan; Asch, Steven

    2009-01-01

    We sought to determine whether groups traditionally most vulnerable to disasters would be more likely than would be others to perceive population-level risk as high (as measured by the estimated color-coded alert level) would worry more about terrorism, and would avoid activities because of terrorism concerns. We conducted a random digit dial survey of the Los Angeles County population October 2004 through January 2005 in 6 languages. We asked respondents what color alert level the country was under, how often they worry about terrorist attacks, and how often they avoid activities because of terrorism. Multivariate regression modeled correlates of worry and avoidance, including mental illness, disability, demographic factors, and estimated color-coded alert level. Persons who are mentally ill, those who are disabled, African Americans, Latinos, Chinese Americans, Korean Americans, and non-US citizens were more likely to perceive population-level risk as high, as measured by the estimated color-coded alert level. These groups also reported more worry and avoidance behaviors because of concerns about terrorism. Vulnerable populations experience a disproportionate burden of the psychosocial impact of terrorism threats and our national response. Further studies should investigate the specific behaviors affected and further elucidate disparities in the disaster burden associated with terrorism and terrorism policies.

  2. Terrorism-Related Fear and Avoidance Behavior in a Multiethnic Urban Population

    PubMed Central

    Glik, Deborah; Ong, Michael; Zhou, Qiong; Tseng, Chi-Hong; Long, Anna; Fielding, Jonathan; Asch, Steven

    2009-01-01

    Objectives. We sought to determine whether groups traditionally most vulnerable to disasters would be more likely than would be others to perceive population-level risk as high (as measured by the estimated color-coded alert level) would worry more about terrorism, and would avoid activities because of terrorism concerns. Methods. We conducted a random digit dial survey of the Los Angeles County population October 2004 through January 2005 in 6 languages. We asked respondents what color alert level the country was under, how often they worry about terrorist attacks, and how often they avoid activities because of terrorism. Multivariate regression modeled correlates of worry and avoidance, including mental illness, disability, demographic factors, and estimated color-coded alert level. Results. Persons who are mentally ill, those who are disabled, African Americans, Latinos, Chinese Americans, Korean Americans, and non-US citizens were more likely to perceive population-level risk as high, as measured by the estimated color-coded alert level. These groups also reported more worry and avoidance behaviors because of concerns about terrorism. Conclusions. Vulnerable populations experience a disproportionate burden of the psychosocial impact of terrorism threats and our national response. Further studies should investigate the specific behaviors affected and further elucidate disparities in the disaster burden associated with terrorism and terrorism policies. PMID:19008521

  3. Color visualization of cyclic magnitudes

    NASA Astrophysics Data System (ADS)

    Restrepo, Alfredo; Estupiñán, Viviana

    2014-02-01

    We exploit the perceptual, circular ordering of the hues in a technique for the visualization of cyclic variables. The hue is thus meaningfully used for the indication of variables such as the azimuth and the units of the measurement of time. The cyclic (or circular) variables may be both of the continuous type or the discrete type; among the first there is azimuth and among the last you find the musical notes and the days of the week. A correspondence between the values of a cyclic variable and the chromatic hues, where the natural circular ordering of the variable is respected, is called a color code for the variable. We base such a choice of hues on an assignment of of the unique hues red, yellow, green and blue, or one of the 8 even permutations of this ordered list, to 4 cardinal values of the cyclic variable, suitably ordered; color codes based on only 3 cardinal points are also possible. Color codes, being intuitive, are easy to remember. A possible low accuracy when reading instruments that use this technique is compensated by fast, ludic and intuitive readings; also, the use of a referential frame makes readings precise. An achromatic version of the technique, that can be used by dichromatic people, is proposed.

  4. Applications of surface acoustic and shallow bulk acoustic wave devices

    NASA Astrophysics Data System (ADS)

    Campbell, Colin K.

    1989-10-01

    Surface acoustic wave (SAW) device coverage includes delay lines and filters operating at selected frequencies in the range from about 10 MHz to 11 GHz; modeling with single-crystal piezoelectrics and layered structures; resonators and low-loss filters; comb filters and multiplexers; antenna duplexers; harmonic devices; chirp filters for pulse compression; coding with fixed and programmable transversal filters; Barker and quadraphase coding; adaptive filters; acoustic and acoustoelectric convolvers and correlators for radar, spread spectrum, and packet radio; acoustooptic processors for Bragg modulation and spectrum analysis; real-time Fourier-transform and cepstrum processors for radar and sonar; compressive receivers; Nyquist filters for microwave digital radio; clock-recovery filters for fiber communications; fixed-, tunable-, and multimode oscillators and frequency synthesizers; acoustic charge transport; and other SAW devices for signal processing on gallium arsenide. Shallow bulk acoustic wave device applications include gigahertz delay lines, surface-transverse-wave resonators employing energy-trapping gratings, and oscillators with enhanced performance and capability.

  5. 21 CFR 206.10 - Code imprint required.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Code imprint required. 206.10 Section 206.10 Food...: GENERAL IMPRINTING OF SOLID ORAL DOSAGE FORM DRUG PRODUCTS FOR HUMAN USE § 206.10 Code imprint required... imprint that, in conjunction with the product's size, shape, and color, permits the unique identification...

  6. Color-Coded Clues to Composition Superimposed on Martian Seasonal-Flow Image

    NASA Image and Video Library

    2014-02-10

    This image from NASA Mar Reconnaissance Orbiter combines a photograph of seasonal dark flows on a Martian slope at Palikir Crater with a grid of colors based on data collected by a mineral-mapping spectrometer observing the same area.

  7. [Performances and place of sonography in the diagnostic of endometriosis: CNGOF-HAS Endometriosis Guidelines].

    PubMed

    Philip, C-A; Dubernard, G

    2018-03-01

    Endometriosis is difficult to diagnose clinically. Transvaginal sonography (TVS) is a procedure that is known to be operator-dependent, which mean that published evidences has to be balanced with the level of the sonographer that produced the data. The objective of this publication was to assess the performances of the sonography in the diagnosis of endometriosis in order to establish the French national recommendations. We searched the MEDLINE database for publication from January 2000 to September 2017 using keywords associated with endometriosis and sonography. Eighty-four trial and reviews published in English or French were included. Ovarian endometrioma can usually be diagnosed by a non-expert sonographer, especially when its aspect is typical. In case of an ovarian cyst with atypical presentation, it is recommended to control the sonography by a referent or to perform an MRI. In menopaused women, any ovarian cyst should be considered as a cancer until proven otherwise. In the diagnosis of posterior deep invasive endometriosis (DIE), TVS with sensitivity and specificity of 96 and 99% respectively, seems at least equivalent if not superior to MRI. However, these performances are related to expert sonographers. To reach sufficient efficiency in posterior DIE, the estimated learning curve for a sonographer is 44 cases. When posterior DIE is suspected, we recommend proposing a TVS "performed by an expert" or a MRI "at least interpreted by an expert". In anterior DIE, TVS has a good specificity (100%), but its sensitivity is poor in the literature (64%). TVS is therefore not able to eliminate the diagnosis. However a renal ultrasound should be proposed each time a urinary endometriosis is confirmed, and should be considered whenever posterior DIE is diagnosed especially the lesion is superior to 3cm. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  8. Correlation between sonography and antibody activity in patients with Hashimoto thyroiditis.

    PubMed

    Willms, Arnulf; Bieler, Dan; Wieler, Helmut; Willms, Diana; Kaiser, Klaus P; Schwab, Robert

    2013-11-01

    Patients with Hashimoto thyroiditis show structural changes of the thyroid that can be identified by a variety of sonographic criteria. We conducted this study to investigate whether there is a correlation between sonography and antibody activity and to assess the role of sonography in the diagnosis and follow-up of Hashimoto thyroiditis. In addition, we present a new classification system (termed the VESINC system [volume, echogenicity, sonographic texture, pseudonodular hypoechoic infiltration, nodules, and cysts]), which helps improve the clarity of sonographic findings. The study included 223 consecutive patients with previously diagnosed Hashimoto autoimmune thyroiditis who attended the thyroid clinic of the German Armed Forces Central Hospital in Koblenz for follow-up examinations between 2006 and 2008. Laboratory tests were performed to measure the levels of free triiodothyronine, free thyroxine, thyrotropin, anti-thyroglobulin antibodies (TgAbs), and antithyroid peroxidase antibodies (TPOAbs). Sonography was performed according to a strict protocol. We then assessed whether a correlation existed between antibody activity and the 6 sonographic variables of the VESINC system. Hypoechogenicity, heterogeneity, and pseudonodular hypoechoic infiltration were associated with significantly higher TPOAb activity (P < .001). There were no significant correlations between the other sonographic variables examined (cysts, nodules, and volume) or the biometric data with the TPOAb and TgAb levels. In addition, an assessment of TgAb levels did not show significant differences in correlations with any of the sonographic variables. Sonography is a noninvasive diagnostic imaging modality that provides information about the level of inflammatory activity. Markedly decreased echogenicity, heterogeneity, and multifocal pseudoinodular hypoechoic infiltration are indicative of a high level of inflammatory activity. The sonographic classification system presented here (VESINC system) can be a useful tool for comparing sonographic findings in a rapid and objective manner during follow-up of Hashimoto thyroiditis.

  9. Targeted hepatic sonography during clinic visits for detection of fatty liver in overweight children: a pilot study.

    PubMed

    Perito, Emily R; Tsai, Patrika M; Hawley, Sarah; Lustig, Robert H; Feldstein, Vickie A

    2013-04-01

    The purpose of this study was to assess the feasibility and utility of targeted hepatic sonography to evaluate for hepatic steatosis during a subspecialty clinic visit. In this pilot study, we performed targeted hepatic sonography on 25 overweight children aged 7 to 17 years consecutively seen in a pediatric obesity clinic. Long-axis images of the right lobe of the liver and a split-screen image of liver and spleen were taken. Images were interpreted in real time by the radiologist and shown to the family. Demographics, clinical measurements, and laboratory parameters were also collected from the specialty clinic visit on the same day. Sonography required a median of 4 minutes during the visit (interquartile range, 3-5 minutes). All consented patients completed the study. The median alanine aminotransferase (ALT) level was 23 U/L in those with no steatosis (n = 14), 26 U/L with mild steatosis (n = 6), and 41 U/L with moderate/marked steatosis (n = 5). Children with ALT levels of 25 to 50 U/L had very variable sonographic measures of hepatic steatosis. When the participants were categorized by the overall degree of fatty liver, hepatic steatosis was significantly associated with the aspartate aminotransferase level (P = .028), ALT level (P = .003), and diastolic blood pressure (P = .05) but did not correlate with age, sex, Latino race, or insulin resistance. Targeted hepatic sonography added information not apparent from routine ALT screening and provided immediate feedback to clinicians and families about the effect of obesity on end organs. This examination could be a feasible, informative addition to screening for children at high risk for nonalcoholic fatty liver disease who are seen in clinics that specialize in obesity.

  10. Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

    NASA Technical Reports Server (NTRS)

    Sargsyan, Ashot E.; Bouffard, Antonio J.; Garcia, Kathleen; Hamilton, Douglas R.; Van Holsbeeck, Marnix; Ebert, Douglas J. W.; Dulchavsky, Scott A.

    2010-01-01

    Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

  11. Prolonged CT urography in duplex kidney.

    PubMed

    Gong, Honghan; Gao, Lei; Dai, Xi-Jian; Zhou, Fuqing; Zhang, Ning; Zeng, Xianjun; Jiang, Jian; He, Laichang

    2016-05-13

    Duplex kidney is a common anomaly that is frequently associated with multiple complications. Typical computed tomography urography (CTU) includes four phases (unenhanced, arterial, parenchymal and excretory) and has been suggested to considerably aid in the duplex kidney diagnosi. Unfortunately, regarding duplex kidney with prolonged dilatation, the affected parenchyma and tortuous ureters demonstrate a lack of or delayed excretory opacification. We used prolonged-delay CTU, which consists of another prolonged-delay phase (1- to 72-h delay; mean delay: 24 h) to opacify the duplicated ureters and affected parenchyma. Seventeen patients (9 males and 8 females; age range: 2.5-56 y; mean age: 40.4 y) with duplex kidney were included in this study. Unenhanced scans did not find typical characteristics of duplex kidney, except for irregular perirenal morphology. Duplex kidney could not be confirmed on typical four-phase CTU, whereas it could be easily diagnosed in axial and CT-3D reconstruction using prolonged CTU (prolonged-delay phase). Between January 2005 and October 2010, in this review board-approved study (with waived informed consent), 17 patients (9 males and 8 females; age range: 2.5 ~ 56 y; mean age: 40.4 y) with suspicious duplex kidney underwent prolonged CTU to opacify the duplicated ureters and confirm the diagnosis. Our results suggest the validity of prolonged CTU to aid in the evaluation of the function of the affected parenchyma and in the demonstration of urinary tract malformations.

  12. [A Duplex PCR Method for Detection of Babesia caballi and Theileria equi].

    PubMed

    Zhang, Yang; Zhang, Yu-ting; Wang, Zhen-bao; Bolati; Li, Hai; Bayinchahan

    2015-04-01

    To develop a duplex PCR assay for detection of Babesia caballi and Theileria equi. Two pairs of primers were designed according to the BC48 gene of B. caballi and 18 s rRNA gene of T. equi, and a duplex PCR assay was developed by the optimization of reaction conditions. The specificity, sensitivity and reliability of the method were tested. The horse blood samples of suspected cases were collected from Yili region, and detected by the duplex PCR, microspopy, conventional PCR, and fluorescence quantitative PCR, and the results were compared. Using the duplex PCR assay, the specific fragments of 155 bp and 280 bp were amplified from DNA samples of B. caballi and T. equi, respectively. No specific fragment was amplified from DNA samples of B. bigemina, Theilerdia annulata, Theilerdia sergenti, Toxoplasma gondii, Neospora caninum, and Trypanosoma evansi. The limit of detection was 4.85 x 10(5) copies/L for B. caballi DNA and 4.85 x 10(4) copies/µl for T. equi DNA, respectively. Among the 24 blood samples, 11 were found B. caballi-positive by the duplex PCR assay, and 18 were T. equi-positive. The coincidence rate of microscopy, conventional PCR, and fluorescence quantitative PCR with duplex PCR was 91.7% (22/24), 95.8% (23/24), and 95.8% (23/24), respectively. A duplex PCR assay for simultaneous detection of B. caballi and T. equi is established.

  13. l-Proline and RNA Duplex m-Value Temperature Dependence.

    PubMed

    Schwinefus, Jeffrey J; Baka, Nadia L; Modi, Kalpit; Billmeyer, Kaylyn N; Lu, Shutian; Haase, Lucas R; Menssen, Ryan J

    2017-08-03

    The temperature dependence of l-proline interactions with the RNA dodecamer duplex surface exposed after unfolding was quantified using thermal and isothermal titration denaturation monitored by uv-absorbance. The m-value quantifying proline interactions with the RNA duplex surface area exposed after unfolding was measured using RNA duplexes with GC content ranging between 17 and 83%. The m-values from thermal denaturation decreased with increasing GC content signifying increasingly favorable proline interactions with the exposed RNA surface area. However, m-values from isothermal titration denaturation at 25.0 °C were independent of GC content and less negative than those from thermal denaturation. The m-value from isothermal titration denaturation for a 50% GC RNA duplex decreased (became more negative) as the temperature increased and was in nearly exact agreement with the m-value from thermal denaturation. Since RNA duplex transition temperatures increased with GC content, the more favorable proline interactions with the high GC content duplex surface area observed from thermal denaturation resulted from the temperature dependence of proline interactions rather than the RNA surface chemical composition. The enthalpy contribution to the m-value was positive and small (indicating a slight increase in duplex unfolding enthalpy with proline) while the entropic contribution to the m-value was positive and increased with temperature. Our results will facilitate proline's use as a probe of solvent accessible surface area changes during biochemical reactions at different reaction temperatures.

  14. Translational Entropy and DNA Duplex Stability.

    PubMed

    Privalov, Peter L; Crane-Robinson, Colyn

    2018-01-09

    Investigation of folding/unfolding DNA duplexes of various size and composition by superprecise calorimetry has revised several long-held beliefs concerning the forces responsible for the formation of the double helix. It was established that: 1) the enthalpy and the entropy of duplex unfolding are temperature dependent, increasing with temperature rise and having the same heat capacity increment for CG and AT pairs; 2) the enthalpy of AT melting is greater than that of the CG pair, so the stabilizing effect of the CG pair in comparison with AT results not from its larger enthalpic contribution (as expected from its extra hydrogen bond), but from the larger entropic contribution of the AT pair that results from its ability to fix ordered water in the minor groove and release it upon duplex unfolding; 3) the translation entropy, resulting from the appearance of a new kinetic unit on duplex dissociation, determines the dependence of duplex stability on its length and its concentration (it is an order-of-magnitude smaller than predicted from the statistical mechanics of gases and is fully expressed by the stoichiometric correction term); 4) changes in duplex stability on reshuffling the sequence (the "nearest-neighbor effect") result from the immobilized water molecules fixed by AT pairs in the minor groove; and 5) the evaluated thermodynamic components permit a quantitative expression of DNA duplex stability. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  15. Solution structure and stability of the DNA undecamer duplexes containing oxanine mismatch

    PubMed Central

    Pack, Seung Pil; Morimoto, Hirohisa; Makino, Keisuke; Tajima, Kunihiko; Kanaori, Kenji

    2012-01-01

    Solution structures of DNA duplexes containing oxanine (Oxa, O) opposite a cytosine (O:C duplex) and opposite a thymine (O:T duplex) have been solved by the combined use of 1H NMR and restrained molecular dynamics calculation. One mismatch pair was introduced into the center of the 11-mer duplex of [d(GTGACO6CACTG)/d(CAGTGX17GTCAC), X = C or T]. 1H NMR chemical shifts and nuclear Overhauser enhancement (NOE) intensities indicate that both the duplexes adopt an overall right-handed B-type conformation. Exchangeable resonances of C17 4-amino proton of the O:C duplex and of T17 imino proton of O:T duplex showed unusual chemical shifts, and disappeared with temperature increasing up to 30°C, although the melting temperatures were >50°C. The O:C mismatch takes a wobble geometry with positive shear parameter where the Oxa ring shifted toward the major groove and the paired C17 toward the minor groove, while, in the O:T mismatch pair with the negative shear, the Oxa ring slightly shifted toward the minor groove and the paired T17 toward the major groove. The Oxa mismatch pairs can be wobbled largely because of no hydrogen bond to the O1 position of the Oxa base, and may occupy positions in the strands that optimize the stacking with adjacent bases. PMID:22039100

  16. Analysis of Structural Flexibility of Damaged DNA Using Thiol-Tethered Oligonucleotide Duplexes

    PubMed Central

    Fujita, Masashi; Watanabe, Shun; Yoshizawa, Mariko; Yamamoto, Junpei; Iwai, Shigenori

    2015-01-01

    Bent structures are formed in DNA by the binding of small molecules or proteins. We developed a chemical method to detect bent DNA structures. Oligonucleotide duplexes in which two mercaptoalkyl groups were attached to the positions facing each other across the major groove were prepared. When the duplex contained the cisplatin adduct, which was proved to induce static helix bending, interstrand disulfide bond formation under an oxygen atmosphere was detected by HPLC analyses, but not in the non-adducted duplex, when the two thiol-tethered nucleosides were separated by six base pairs. When the insert was five and seven base pairs, the disulfide bond was formed and was not formed, respectively, regardless of the cisplatin adduct formation. The same reaction was observed in the duplexes containing an abasic site analog and the (6–4) photoproduct. Compared with the cisplatin case, the disulfide bond formation was slower in these duplexes, but the reaction rate was nearly independent of the linker length. These results indicate that dynamic structural changes of the abasic site- and (6–4) photoproduct-containing duplexes could be detected by our method. It is strongly suggested that the UV-damaged DNA-binding protein, which specifically binds these duplexes and functions at the first step of global-genome nucleotide excision repair, recognizes the easily bendable nature of damaged DNA. PMID:25679955

  17. Development of nano-structured duplex and ferritic stainless steels by pulverisette planetary milling followed by pressureless sintering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R, Shashanka, E-mail: shashankaic@gmail.com; Chaira, D., E-mail: chaira.debasis@gmail.com

    Nano-structured duplex and ferritic stainless steel powders are prepared by planetary milling of elemental Fe, Cr and Ni powder for 40 h and then consolidated by conventional pressureless sintering. The progress of milling and the continuous refinement of stainless steel powders have been confirmed by means of X-ray diffraction and scanning electron microscopy. Activation energy for the formation of duplex and ferritic stainless steels is calculated by Kissinger method using differential scanning calorimetry and is found to be 159.24 and 90.17 KJ/mol respectively. Both duplex and ferritic stainless steel powders are consolidated at 1000, 1200 and 1400 °C in argonmore » atmosphere to study microstructure, density and hardness. Maximum sintered density of 90% and Vickers microhardness of 550 HV are achieved for duplex stainless steel sintered at 1400 °C for 1 h. Similarly, 92% sintered density and 263 HV microhardness are achieved for ferritic stainless steel sintered at 1400 °C. - Highlights: • Synthesized duplex and ferritic stainless steels by pulverisette planetary milling • Calculated activation energy for the formation of duplex and ferritic stainless steels • Studied the effect of sintering temperature on density, hardness and microstructure • Duplex stainless steel exhibits 90% sintered density and microhardness of 550 HV. • Ferritic stainless steel shows 92% sintered density and 263 HV microhardness.« less

  18. Diagnosis of peritoneal mesothelioma: computed tomography, sonography, and fine-needle aspiration biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reuter, K.; Raptopoulos, V.; Reale, F.

    1983-06-01

    The diagnosis of peritoneal mesothelioma was made prospectively and noninvasively in four patients with the use of sonography, computed tomography, and sonographically guided fine-needle aspiration biopsy. The imaging methods revealed information similar to the operative findings, with clear superiority of computed tomography over sonography. These noninvasive methods may be used as screening tools, especially among groups or in regional areas with a high risk for asbestos exposure. The findings included soft-tissue masses with invariable involvement of the omentum; small intraperitoneal nodules; thickened peritoneum, mesentery, and bowel wall; pleural plaques; and usually minimal, if any, ascites. Since the differential diagnosis frommore » peritoneal carcinomatosis may be difficult, sonographically (or CT) guided aspiration biopsy is needed to produce diagnostic cytologic specimens. The use of this type of biopsy should obviate surgical exploration.« less

  19. Improvement in cochlear flow in patients with tinnitus with the complex supplement Acustop: a product evaluation.

    PubMed

    Grossi, M G; Belcaro, G; Cesarone, M R; Dugall, M; Hosoi, M; Cacchio, M; Ippolito, E; Bavera, P

    2011-09-01

    Patients with tinnitus constitute a very large group without a real, specific therapeutic solution. With noninvasive, color duplex it is possible to measure flow in the cochlear artery and to follow duplex flow changes due to treatments in most patients. The aim of this preliminary evaluation was to study flow variations in patients with "mild-to-moderate" tinnitus, possibly associated to cochlear hypo-perfusion, after administration of Acustop (used as a food supplement). The aim was to improve cochlear flow decreasing the level of tinnitus. Patients with "mild-to-moderate", "idiopathic", monolateral tinnitus, present for at least 4 weeks were included; no vertigo or important hearing loss had been observed. The origin of tinnitus had been sudden (hours or days). The tinnitus was associated to a decrease in cochlear flow measured by color Duplex at the affected ear. A group of 42 patients was evaluated; 25 used Acustop; there were 17 controls (follow-up only). Groups were comparable for their clinical problem and other details. The average duration of treatment was 4 weeks. No side effects were observed and no drop-outs were recorded. Flow velocity at the level of the affected inner ear was significantly lower (both the diastolic and systolic components; P<0.05) in comparison with the other ear. This was considered an indication of the vascular origin of the tinnitus. With Acustop treatment there was a significant improvement in systolic (P<0.05) and diastolic flow velocity (P<0.05). The increase in flow velocity was not significant in controls. An analogue scale line was used to measure symptoms in the Acustop group: it was 8.2;2 at inclusion; it decreased to 3.1;1.5 at 4 weeks (P<0.05). The score was 8.4;2 in controls at inclusion; at 4 weeks the score was 7.1;2.2 (not significant). Tinnitus scale: the value at inclusion of the tinnitus scale in the Acustop group a was 8.5;1.1 versus 8.3;1.2 in controls. After 4 weeks the score was 3.1;1.1 (P<0.05) in the Acustop group vs 7.2 in controls; the difference between the two groups was significant; P<0.025). In conclusion, these results suggest that in selected patients with tinnitus and altered inner ear perfusion Acustop appears to be effective in relieving tinnitus possibly by improving cochlear flow. More studies should be planned to evaluate better the potential applications of Acustop in this very interesting field. This clinical problem affects a large number of patients, without a real therapeutic solution at the moment, decreasing their quality of life and their performing abilities.

  20. Venous duplex and pathologic differences in thrombus characteristics between de novo deep vein thrombi and endovenous heat-induced thrombi.

    PubMed

    Santin, Brian J; Lohr, Joanne M; Panke, Thomas W; Neville, Patrick M; Felinski, Melissa M; Kuhn, Brian A; Recht, Matthew H; Muck, Patrick E

    2015-04-01

    Superficial venous reflux disease has been treated with endovenous ablation techniques for more than 15 years. Thrombi discovered in the postoperative period are referred to as endovenous heat-induced thrombi (EHIT). In spite of the few studies of the ultrasound differentiation between EHIT and deep vein thrombi (DVT), there remains a paucity of literature regarding the evaluation of ultrasound examination and pathologic differentiation. Six Yorkshire cross swine underwent femoral vein thrombosis by suture ligation or endovenous radiofrequency ablation. At 1 week after the procedure, each femoral vein was imaged by color Duplex ultrasound and sent for histologic interpretation for differentiation between EHIT and DVT. Five blinded vascular surgery faculty, two vascular surgery fellows, and three vascular surgery residents reviewed the ultrasound images. Thrombi associated with radiofrequency ablation demonstrated a greater degree of hypercellular response, fibroblastic reaction, and edema (3.42 vs 2.92; 3.75 vs 2.42; 2.83 vs 1.33). Specimens harvested from the iatrogenic-induced DVT swine demonstrated a more prolific response to trichrome staining (3.42 vs 2.67). Evidence of revascularization was found in all of the EHIT specimens but in 33% of DVT specimens. On the basis of histologic findings, the pathologist predicted correct modality 92% of the time. Subgroup analysis comparing paired specimens from each swine failed to demonstrate any marked pathologic differences. Recorded ultrasound images from EHIT and DVT samples were reviewed by fellows, residents, and vascular surgery staff to determine whether clot was stationary or free-floating (n = 111; 93%), evidence of retracted or adherent vein (n = 105; 88%), and absence of color flow (n = 102; 85%). The degree of occlusion (partial vs total) and degree of distention of a visualized vein were least likely to be agreed on by reviewers (n = 95; 79% each, respectively). In subgroup (DVT vs EHIT) analyses, the percentage agreement was greatest among vascular surgery fellows (89% and 92%) compared with residents (82% and 79%) and faculty (78% and 77%). It is possible to differentiate the thrombus origin on pathologic examination but not clinically on ultrasound. Wide variability exists for ultrasound diagnosis of EHIT and de novo DVT. Care must be taken in evaluating post-treatment duplex scans to not assign diagnosis of EHIT when DVT may well be present and extending into the deep venous system. The modulation of collagen production in the treatment of DVT may be helpful in preventing vascular dysfunction and reducing the post-thrombotic changes. Further studies on injury after radiofrequency ablation and laser ablation are needed. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Ability of the D-15 panel tests and HRR pseudoisochromatic plates to predict performance in naming VDT colors.

    PubMed

    Ramaswamy, Shankaran; Hovis, Jeffery K

    2004-01-01

    Color codes in VDT displays often contain sets of colors that are confusing to individuals with color-vision deficiencies. The purpose of this study is to determine whether individuals with color-vision deficiencies (color defectives) can perform as well as individuals without color-vision deficiencies (color normals) on a colored VDT display used in the railway industry and to determine whether clinical color-vision tests can predict their performance. Of the 52 color defectives, 58% failed the VDT test. The kappa coefficients of agreement for the Farnsworth D-15, Adams desaturated D-15, and Richmond 3rd Edition HRR PIC diagnostic plates were significantly greater than chance. In particular, the D-15 tests have a high probability of predicting who fails the practical test. However, all three tests had an unacceptably high false-negative rate (9.5-35%); so that a practical test is still needed.

  2. The Crystal Structure of Non-Modified and Bipyridine-Modified PNA Duplexes

    PubMed Central

    Yeh, Joanne I.; Pohl, Ehmke; Truan, Daphne; He, Wei; Sheldrick, George M.; Du, Shoucheng; Achim, Catalina

    2011-01-01

    Peptide nucleic acid (PNA) is a synthetic analogue of DNA that commonly has an N-aminoethlyl-glycine backbone. The crystal structure of two PNA duplexes, one containing eight standard nucleobase pairs (GGCATCGG)2 (pdb: 3MBS), and the other containing the same nucleobase pairs and a central pair of bipyridine ligands (pdb: 3MBU), has been solved with a resolution of 1.2 Å and 1.05 Å, respectively. The non-modified PNA duplex adopts a P-type helical structure s i m i l a r t o that of previously characterized PNAs. The atomic-level resolution of the structures allowed us to observe for the first time specific modes of interaction between the terminal lysines of the PNA and the backbone and nucleobases situated in the vicinity of the lysines, which are considered an important factor in the induction of a preferred handedness in PNA duplexes. These results support the notion that while PNA typically adopts a P-type helical structure, its flexibility is relatively high. For example, the base pair rise in the bipyridine-containing PNA is the largest measured to date in a PNA homoduplex. The two bipyridines are bulged out of the duplex and are aligned parallel to the minor groove of the PNA. In the case of the bipyridine-containing PNA, two bipyridines from adjacent PNA duplexes form a π-stacked pair that relates the duplexes within the crystal. The bulging out of the bipyridines causes bending of the PNA duplex, which is in contrast to the structure previously reported for biphenyl-modified DNA duplexes in solution, where the biphenyls are π-stacking with adjacent nucleobase pairs and adopt an intrahelical geometry [Johar et al., Chem. Eur. J., 2008, 14, 2080]. This difference shows that relatively small perturbations can significantly impact the relative position of nucleobase analogues in nucleic acid duplexes. PMID:20859960

  3. Thermodynamics of RNA duplexes modified with unlocked nucleic acid nucleotides

    PubMed Central

    Pasternak, Anna; Wengel, Jesper

    2010-01-01

    Thermodynamics provides insights into the influence of modified nucleotide residues on stability of nucleic acids and is crucial for designing duplexes with given properties. In this article, we introduce detailed thermodynamic analysis of RNA duplexes modified with unlocked nucleic acid (UNA) nucleotide residues. We investigate UNA single substitutions as well as model mismatch and dangling end effects. UNA residues placed in a central position makes RNA duplex structure less favourable by 4.0–6.6 kcal/mol. Slight destabilization, by ∼0.5–1.5 kcal/mol, is observed for 5′- or 3′-terminal UNA residues. Furthermore, thermodynamic effects caused by UNA residues are extremely additive with ΔG°37 conformity up to 98%. Direct mismatches involving UNA residues decrease the thermodynamic stability less than unmodified mismatches in RNA duplexes. Additionally, the presence of UNA residues adjacent to unpaired RNA residues reduces mismatch discrimination. Thermodynamic analysis of UNA 5′- and 3′-dangling ends revealed that stacking interactions of UNA residues are always less favourable than that of RNA residues. Finally, circular dichroism spectra imply no changes in overall A-form structure of UNA–RNA/RNA duplexes relative to the unmodified RNA duplexes. PMID:20562222

  4. Displaying Geographically-Based Domestic Statistics

    NASA Technical Reports Server (NTRS)

    Quann, J.; Dalton, J.; Banks, M.; Helfer, D.; Szczur, M.; Winkert, G.; Billingsley, J.; Borgstede, R.; Chen, J.; Chen, L.; hide

    1982-01-01

    Decision Information Display System (DIDS) is rapid-response information-retrieval and color-graphics display system. DIDS transforms tables of geographically-based domestic statistics (such as population or unemployment by county, energy usage by county, or air-quality figures) into high-resolution, color-coded maps on television display screen.

  5. Pediatric intensive care unit admission tool: a colorful approach.

    PubMed

    Biddle, Amy

    2007-12-01

    This article discusses the development, implementation, and utilization of our institution's Pediatric Intensive Care Unit (PICU) Color-Coded Admission Status Tool. Rather than the historical method of identifying a maximum number of staffed beds, a tool was developed to color code the PICU's admission status. Previous methods had been ineffective and led to confusion between the PICU leadership team and the administration. The tool includes the previously missing components of staffing and acuity, which are essential in determining admission capability. The PICU tool has three colored levels: green indicates open for admissions; yellow, admission alert resulting from available beds or because staffing is not equal to the projected patient numbers or required acuity; and red, admissions on hold because only one trauma or arrest bed is available or staffing is not equal to the projected acuity. Yellow and red designations require specific actions and the medical director's approval. The tool has been highly successful and significantly impacted nursing with the inclusion of the essential component of nurse staffing necessary in determining bed availability.

  6. Laser-based volumetric flow visualization by digital color imaging of a spectrally coded volume.

    PubMed

    McGregor, T J; Spence, D J; Coutts, D W

    2008-01-01

    We present the framework for volumetric laser-based flow visualization instrumentation using a spectrally coded volume to achieve three-component three-dimensional particle velocimetry. By delivering light from a frequency doubled Nd:YAG laser with an optical fiber, we exploit stimulated Raman scattering within the fiber to generate a continuum spanning the visible spectrum from 500 to 850 nm. We shape and disperse the continuum light to illuminate a measurement volume of 20 x 10 x 4 mm(3), in which light sheets of differing spectral properties overlap to form an unambiguous color variation along the depth direction. Using a digital color camera we obtain images of particle fields in this volume. We extract the full spatial distribution of particles with depth inferred from particle color. This paper provides a proof of principle of this instrument, examining the spatial distribution of a static field and a spray field of water droplets ejected by the nozzle of an airbrush.

  7. The use of computer-generated color graphic images for transient thermal analysis. [for hypersonic aircraft

    NASA Technical Reports Server (NTRS)

    Edwards, C. L. W.; Meissner, F. T.; Hall, J. B.

    1979-01-01

    Color computer graphics techniques were investigated as a means of rapidly scanning and interpreting large sets of transient heating data. The data presented were generated to support the conceptual design of a heat-sink thermal protection system (TPS) for a hypersonic research airplane. Color-coded vector and raster displays of the numerical geometry used in the heating calculations were employed to analyze skin thicknesses and surface temperatures of the heat-sink TPS under a variety of trajectory flight profiles. Both vector and raster displays proved to be effective means for rapidly identifying heat-sink mass concentrations, regions of high heating, and potentially adverse thermal gradients. The color-coded (raster) surface displays are a very efficient means for displaying surface-temperature and heating histories, and thereby the more stringent design requirements can quickly be identified. The related hardware and software developments required to implement both the vector and the raster displays for this application are also discussed.

  8. Enhanced dimension-specific visual working memory in grapheme-color synesthesia.

    PubMed

    Terhune, Devin Blair; Wudarczyk, Olga Anna; Kochuparampil, Priya; Cohen Kadosh, Roi

    2013-10-01

    There is emerging evidence that the encoding of visual information and the maintenance of this information in a temporarily accessible state in working memory rely on the same neural mechanisms. A consequence of this overlap is that atypical forms of perception should influence working memory. We examined this by investigating whether having grapheme-color synesthesia, a condition characterized by the involuntary experience of color photisms when reading or representing graphemes, would confer benefits on working memory. Two competing hypotheses propose that superior memory in synesthesia results from information being coded in two information channels (dual-coding) or from superior dimension-specific visual processing (enhanced processing). We discriminated between these hypotheses in three n-back experiments in which controls and synesthetes viewed inducer and non-inducer graphemes and maintained color or grapheme information in working memory. Synesthetes displayed superior color working memory than controls for both grapheme types, whereas the two groups did not differ in grapheme working memory. Further analyses excluded the possibilities of enhanced working memory among synesthetes being due to greater color discrimination, stimulus color familiarity, or bidirectionality. These results reveal enhanced dimension-specific visual working memory in this population and supply further evidence for a close relationship between sensory processing and the maintenance of sensory information in working memory. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Interobserver variability of sonography for prediction of placenta accreta.

    PubMed

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-12-01

    The sensitivity of sonography to predict accreta has been reported as higher than 90%. However, most studies are from single expert investigators. Our objective was to analyze interobserver variability of sonography for prediction of placenta accreta. Patients with previa with and without accreta were ascertained, and images with placental views were collected, deidentified, and placed in random sequence. Three radiologists and 3 maternal-fetal medicine specialists interpreted each study for the presence of accreta and specific findings reported to be associated with its diagnosis. Investigator-specific sensitivity, specificity, and accuracy were calculated. κ statistics were used to assess variability between individuals and types of investigators. A total of 229 sonographic studies from 55 patients with accreta and 56 control patients were examined. Accuracy ranged from 55.9% to 76.4%. Of imaging studies yielding diagnoses, sensitivity ranged from 53.4% to 74.4%, and specificity ranged from 70.8% to 94.8%. Overall interobserver agreement was moderate (mean κ ± SD = 0.47 ± 0.12). κ values between pairs of investigators ranged from 0.32 (fair agreement) to 0.73 (substantial agreement). Average individual agreement ranged from fair (κ = 0.35) to moderate (κ = 0.53). Blinded from clinical data, sonography has significant interobserver variability for the diagnosis of placenta accreta. © 2013 by the American Institute of Ultrasound in Medicine.

  10. Does Bedside Sonography Effectively Identify Nasogastric Tube Placements in Pediatric Critical Care Patients?

    PubMed

    Atalay, Yunus Oktay; Aydin, Ramazan; Ertugrul, Omer; Gul, Selim Baris; Polat, Ahmet Veysel; Paksu, Muhammet Sukru

    2016-12-01

    A nasogastric tube (NGT) insertion is a common procedure in intensive care units, with some serious complications that result from the malposition of the NGT tip. This pilot study was designed to investigate the efficiency of ultrasound in verifying correct NGT placement and to compare these results with radiographic findings. This was a single-center, double-blind prospective study of patients who had received an NGT in the pediatric critical care unit. Twenty-one patients aged 1 month to 18 years were included in this study. All NGTs were inserted by the same critical care physician. After insertion, the physician first confirmed NGT placement by the auscultation of the epigastrium following the insufflation of air. Confirmation was supplemented with an abdominal radiograph. A radiologist who was unaware of the radiographic findings performed bedside sonography on all patients and verified the location of the NGTs. The findings from these 2 physicians were then compared. NGTs were inserted without any complications, and none of the NGTs were positioned in the respiratory tract in any of the patients. All NGT tips were visualized by radiography and sonography with a sensitivity of 100%. Bedside sonography performed by a radiologist is an effective and sensitive diagnostic procedure for confirming the correct NGT position in patients in the pediatric critical care unit.

  11. Role of Arrival Time Difference Between Lesions and Lung Tissue on Contrast-Enhanced Sonography in the Differential Diagnosis of Subpleural Pulmonary Lesions.

    PubMed

    Bai, Jing; Yang, Wei; Wang, Song; Guan, Rui-Hong; Zhang, Hui; Fu, Jing-Jing; Wu, Wei; Yan, Kun

    2016-07-01

    The purpose of this study was to explore the diagnostic value of the arrival time difference between lesions and surrounding lung tissue on contrast-enhanced sonography of subpleural pulmonary lesions. A total of 110 patients with subpleural pulmonary lesions who underwent both conventional and contrast-enhanced sonography and had a definite diagnosis were enrolled. After contrast agent injection, the arrival times in the lesion, lung, and chest wall were recorded. The arrival time differences between various tissues were also calculated. Statistical analysis showed a significant difference in the lesion arrival time, the arrival time difference between the lesion and lung, and the arrival time difference between the chest wall and lesion (all P < .001) for benign and malignant lesions. Receiver operating characteristic curve analysis revealed that the optimal diagnostic criterion was the arrival time difference between the lesion and lung, and that the best cutoff point was 2.5 seconds (later arrival signified malignancy). This new diagnostic criterion showed superior diagnostic accuracy (97.1%) compared to conventional diagnostic criteria. The individualized diagnostic method based on an arrival time comparison using contrast-enhanced sonography had high diagnostic accuracy (97.1%) with good feasibility and could provide useful diagnostic information for subpleural pulmonary lesions.

  12. Echodense spinal subarachnoid space in neonates with progressive ventricular dilatation: a marker of noncommunicating hydrocephalus.

    PubMed

    Rudas, G; Almássy, Z; Papp, B; Varga, E; Méder, U; Taylor, G A

    1998-10-01

    Our purpose was to evaluate the frequency and clinical significance of echogenic debris in the spinal subarachnoid space of neonates at risk for progressive ventricular dilatation. Spinal sonography was performed on 15 neonates with severe intracranial hemorrhage (n = 10) or bacterial meningitis (n = 5). Spinal sonography also was performed on 16 control neonates. Images were analyzed for the presence and location of echogeric debris within the thoracolumbar subarachnoid space. Lumbar punctures were performed on all 31 neonates, and CSF was analyzed for cell count and protein content. Ten of 15 neonates required ventricular drainage procedures. Progressive ventricular dilatation occurred in 11 of 15 neonates with intracranial hemorrhage or meningitis. Echogenic debris was present in the thoracolumbar subarachnoid space on spinal sonography in every neonate with progressive ventricular dilatation compared with none of the 16 control neonates (p < .0001 by chi-square analysis). In addition, the 11 neonates with echogenic subarachnoid space had significantly higher protein and RBC contents in the lumbar CSF (p < .04). Echogenic subarachnoid space revealed by sonography is associated with progressive ventricular dilatation after severe intracranial hemorrhage or bacterial meningitis and is caused by high protein and RBC contents in the subarachnoid space. This finding may be helpful in identifying neonates who will not benefit from serial lumbar punctures for treatment of hydrocephalus.

  13. A case of occipital neuralgia in the greater and lesser occipital nerves treated with neurectomy by using transcranial Doppler sonography: technical aspects.

    PubMed

    Jung, Sang Jin; Moon, Seong Keun; Kim, Tae Young; Eom, Ki Seong

    2011-03-01

    Occipital neuralgia is usually defined as paroxysmal stabbing pain in the greater or lesser occipital nerve (GON or LON) distribution. In occipital neuralgia patients, surgical considerations are carefully taken into account if medical management is ineffective. However, identification of the occipital artery by palpation in patients with thick necks or small occipital arteries can be technically difficult. Therefore, we established a new technique using transcranial Doppler (TCD) sonography for more accurate and rapid identification. The patient was a 64-year-old man who had undergone C1-C3 screw fixation and presented with intractable stabbing pain in the bilateral GON and LON distributions. In cases in which pain management was performed using medication, physical therapy, nerve block, or radiofrequency thermocoagulation, substantial pain relief was not consistently achieved, and recurrence of pain was reported. Therefore, we performed occipital neurectomy of the bilateral GON and LON by using TCD sonography, which helped detect the greater occipital artery easily. After the operation, the patient's headache disappeared gradually, although he had discontinued all medication except antidepressants. We believe that this new technique of occipital neurectomy via a small skin incision performed using TCD sonography is easy and reliable, has a short operative time, and provides rapid pain relief.

  14. A Case of Occipital Neuralgia in the Greater and Lesser Occipital Nerves Treated with Neurectomy by Using Transcranial Doppler Sonography: Technical Aspects

    PubMed Central

    Jung, Sang Jin; Moon, Seong Keun; Kim, Tae Young

    2011-01-01

    Occipital neuralgia is usually defined as paroxysmal stabbing pain in the greater or lesser occipital nerve (GON or LON) distribution. In occipital neuralgia patients, surgical considerations are carefully taken into account if medical management is ineffective. However, identification of the occipital artery by palpation in patients with thick necks or small occipital arteries can be technically difficult. Therefore, we established a new technique using transcranial Doppler (TCD) sonography for more accurate and rapid identification. The patient was a 64-year-old man who had undergone C1-C3 screw fixation and presented with intractable stabbing pain in the bilateral GON and LON distributions. In cases in which pain management was performed using medication, physical therapy, nerve block, or radiofrequency thermocoagulation, substantial pain relief was not consistently achieved, and recurrence of pain was reported. Therefore, we performed occipital neurectomy of the bilateral GON and LON by using TCD sonography, which helped detect the greater occipital artery easily. After the operation, the patient's headache disappeared gradually, although he had discontinued all medication except antidepressants. We believe that this new technique of occipital neurectomy via a small skin incision performed using TCD sonography is easy and reliable, has a short operative time, and provides rapid pain relief. PMID:21390179

  15. Multiple pathogen biomarker detection using an encoded bead array in droplet PCR.

    PubMed

    Periyannan Rajeswari, Prem Kumar; Soderberg, Lovisa M; Yacoub, Alia; Leijon, Mikael; Andersson Svahn, Helene; Joensson, Haakan N

    2017-08-01

    We present a droplet PCR workflow for detection of multiple pathogen DNA biomarkers using fluorescent color-coded Luminex® beads. This strategy enables encoding of multiple singleplex droplet PCRs using a commercially available bead set of several hundred distinguishable fluorescence codes. This workflow provides scalability beyond the limited number offered by fluorescent detection probes such as TaqMan probes, commonly used in current multiplex droplet PCRs. The workflow was validated for three different Luminex bead sets coupled to target specific capture oligos to detect hybridization of three microorganisms infecting poultry: avian influenza, infectious laryngotracheitis virus and Campylobacter jejuni. In this assay, the target DNA was amplified with fluorescently labeled primers by PCR in parallel in monodisperse picoliter droplets, to avoid amplification bias. The color codes of the Luminex detection beads allowed concurrent and accurate classification of the different bead sets used in this assay. The hybridization assay detected target DNA of all three microorganisms with high specificity, from samples with average target concentration of a single DNA template molecule per droplet. This workflow demonstrates the possibility of increasing the droplet PCR assay detection panel to detect large numbers of targets in parallel, utilizing the scalability offered by the color-coded Luminex detection beads. Copyright © 2017. Published by Elsevier B.V.

  16. Durability of switchable QR code carriers under hydrolytic and photolytic conditions

    NASA Astrophysics Data System (ADS)

    Ecker, Melanie; Pretsch, Thorsten

    2013-09-01

    Following a guest diffusion approach, the surface of a shape memory poly(ester urethane) (PEU) was either black or blue colored. Bowtie-shaped quick response (QR) code carriers were then obtained from laser engraving and cutting, before thermo-mechanical functionalization (programming) was applied to stabilize the PEU in a thermo-responsive (switchable) state. The stability of the dye within the polymer surface and long-term functionality of the polymer were investigated against UVA and hydrolytic ageing. Spectrophotometric investigations verified UVA ageing-related color shifts from black to yellow-brownish and blue to petrol-greenish whereas hydrolytically aged samples changed from black to greenish and blue to light blue. In the case of UVA ageing, color changes were accompanied by dye decolorization, whereas hydrolytic ageing led to contrast declines due to dye diffusion. The Michelson contrast could be identified as an effective tool to follow ageing-related contrast changes between surface-dyed and laser-ablated (undyed) polymer regions. As soon as the Michelson contrast fell below a crucial value of 0.1 due to ageing, the QR code was no longer decipherable with a scanning device. Remarkably, the PEU information carrier base material could even then be adequately fixed and recovered. Hence, the surface contrast turned out to be the decisive parameter for QR code carrier applicability.

  17. Photophysical Characterization of Enhanced 6-Methylisoxanthopterin Fluorescence in Duplex DNA.

    PubMed

    Moreno, Andrew; Knee, J L; Mukerji, Ishita

    2016-12-08

    The structure and dynamic motions of bases in DNA duplexes and other constructs are important for understanding mechanisms of selectivity and recognition of DNA-binding proteins. The fluorescent guanine analogue, 6-methylisoxanthopterin 6-MI, is well suited to this purpose as it exhibits an unexpected 3- to 4-fold increase in relative quantum yield upon duplex formation when incorporated into the following sequences: ATFAA, AAFTA, or ATFTA (where F represents 6-MI). To better understand some of the factors leading to the 6-MI fluorescence increase upon duplex formation, we characterized the effect of local sequence and structural perturbations on 6-MI photophysics through temperature melts, quantum yield measurements, fluorescence quenching assays, and fluorescence lifetime measurements. By examining 21 sequences we have determined that the duplex-enhanced fluorescence (DEF) depends on the composition of bases adjacent to 6-MI and the presence of adenines at locations n ± 2 from the probe. Investigation of duplex stability and local solvent accessibility measurements support a model in which the DEF arises from a constrained geometry of 6-MI in the duplex, which remains H-bonded to cytosine, stacked with adjacent bases and inaccessible to quenchers. Perturbation of DNA structure through the introduction of an unpaired base 3' to 6-MI or a mismatched basepair increases 6-MI dynamic motion leading to fluorescence quenching and a reduction in quantum yield. Molecular dynamics simulations suggest the enhanced fluorescence results from a greater degree of twist at the X-F step relative to the quenched duplexes examined. These results point to a model where adenine residues located at n ± 2 from 6-MI induce a structural geometry with greater twist in the duplex that hinders local motion reducing dynamic quenching and producing an increase in 6-MI fluorescence.

  18. Duplex-assisted carotid artery stenting without administration of contrast medium for patients with chronic kidney disease or allergic reaction.

    PubMed

    Mizowaki, Takashi; Fujita, Atsushi; Imahori, Taichiro; Uyama, Atsushi; Inoue, Satoshi; Kohta, Masaaki; Hamaguchi, Hirotoshi; Sasayama, Takashi; Hosoda, Kohkichi; Kohmura, Eiji

    2016-07-01

    We aimed to investigate the safety and feasibility of duplex-assisted carotid artery stenting (CAS) without administration of contrast medium for the prevention of adverse reactions. Fifteen patients (9 % of all CASs) with severe carotid stenosis (≥70 %) associated with chronic kidney disease (CKD) (stage ≥3) or allergy to contrast medium underwent duplex-assisted CAS without administration of contrast medium over 4 years. The procedural success rate and perioperative complication rates were compared between the duplex-assisted CAS (n = 15) and conventional CAS (n = 153) groups. The technical success rate was 100 % in both groups. Combined stroke or death rates during the post-procedural period did not differ significantly between the duplex-assisted CAS group (0/15, 0 %) and conventional CAS group (4/153, 2.6 %). None of the 14 patients with CKD in the duplex-assisted CAS group experienced further deterioration of renal function. The mean surface radiation dose of participants in the duplex-assisted CAS group (n = 13, 312 ± 131 mGy) was significantly lower than that of the conventional CAS group (n = 31, 1036 ± 571 mGy) (p < 0.001). The mean duration of CAS procedure was not significantly different between the duplex-assisted CAS group (156 ± 39.7 min) and the conventional CAS group (156 ± 37.4 min). Duplex-assisted CAS without administration of contrast medium could be an alternative option in selected patients deemed to be at high risk for renal failure from nephrotoxic contrast medium or who have an allergy to contrast medium.

  19. Probing of miniPEGγ-PNA-DNA Hybrid Duplex Stability with AFM Force Spectroscopy.

    PubMed

    Dutta, Samrat; Armitage, Bruce A; Lyubchenko, Yuri L

    2016-03-15

    Peptide nucleic acids (PNA) are synthetic polymers, the neutral peptide backbone of which provides elevated stability to PNA-PNA and PNA-DNA hybrid duplexes. It was demonstrated that incorporation of diethylene glycol (miniPEG) at the γ position of the peptide backbone increased the thermal stability of the hybrid duplexes (Sahu, B. et al. J. Org. Chem. 2011, 76, 5614-5627). Here, we applied atomic force microscopy (AFM) based single molecule force spectroscopy and dynamic force spectroscopy (DFS) to test the strength and stability of the hybrid 10 bp duplex. This hybrid duplex consisted of miniPEGγ-PNA and DNA of the same length (γ(MP)PNA-DNA), which we compared to a DNA duplex with a homologous sequence. AFM force spectroscopy data obtained at the same conditions showed that the γ(MP)PNA-DNA hybrid is more stable than the DNA counterpart, 65 ± 15 pN vs 47 ± 15 pN, respectively. The DFS measurements performed in a range of pulling speeds analyzed in the framework of the Bell-Evans approach yielded a dissociation constant, koff ≈ 0.030 ± 0.01 s⁻¹ for γ(MP)PNA-DNA hybrid duplex vs 0.375 ± 0.18 s⁻¹ for the DNA-DNA duplex suggesting that the hybrid duplex is much more stable. Correlating the high affinity of γ(MP)PNA-DNA to slow dissociation kinetics is consistent with prior bulk characterization by surface plasmon resonance. Given the growing interest in γ(MP)PNA as well as other synthetic DNA analogues, the use of single molecule experiments along with computational analysis of force spectroscopy data will provide direct characterization of various modifications as well as higher order structures such as triplexes and quadruplexes.

  20. Management of natural resources through automatic cartographic inventory

    NASA Technical Reports Server (NTRS)

    Rey, P. A.; Gourinard, Y.; Cambou, F. (Principal Investigator)

    1974-01-01

    The author has identified the following significant results. Significant correspondence codes relating ERTS imagery to ground truth from vegetation and geology maps have been established. The use of color equidensity and color composite methods for selecting zones of equal densitometric value on ERTS imagery was perfected. Primary interest of temporal color composite is stressed. A chain of transfer operations from ERTS imagery to the automatic mapping of natural resources was developed.

Top