[Venous Doppler color echography: importance and inconveniences].
Laroche, J P; Dauzat, M; Muller, G; Janbon, C
1993-01-01
Color Doppler is a technique which performs a real-time opacification of the vascular system with blue indicating reverse flow and red indicating forward flow (directional color coding). In venous pathology, the use of color Doppler improves significantly the anatomical evaluation of the inferior vena cava, the iliac vein, the deep femoral vein, and the sural system. Color Doppler facilitates the study of deep venous thrombosis (providing useful information to differentiate ancient from most recent thrombus) and also the study of post-thrombotic conditions (assessment of reverse flow, repermeation phenomena). Finally, color Doppler produces a better insight for the study of varicose veins, especially with regard to mapping, identification of communicante veins, and study of the external saphenous vein.
Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J
2015-04-01
A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.
MicroV Technology to Improve Transcranial Color Coded Doppler Examinations.
Malferrari, Giovanni; Pulito, Giuseppe; Pizzini, Attilia Maria; Carraro, Nicola; Meneghetti, Giorgio; Sanzaro, Enzo; Prati, Patrizio; Siniscalchi, Antonio; Monaco, Daniela
2018-05-04
The purpose of this review is to provide an update on technology related to Transcranial Color Coded Doppler Examinations. Microvascularization (MicroV) is an emerging Power Doppler technology which can allow visualization of low and weak blood flows even at high depths, thus providing a suitable technique for transcranial ultrasound analysis. With MicroV, reconstruction of the vessel shape can be improved, without any overestimation. Furthermore, by analyzing the Doppler signal, MicroV allows a global image of the Circle of Willis. Transcranial Doppler was originally developed for the velocimetric analysis of intracranial vessels, in particular to detect stenoses and the assessment of collateral circulation. Doppler velocimetric analysis was then compared to other neuroimaging techniques, thus providing a cut-off threshold. Transcranial Color Coded Doppler sonography allowed the characterization of vessel morphology. In both Color Doppler and Power Doppler, the signal overestimated the shape of the intracranial vessels, mostly in the presence of thin vessels and high depths of study. In further neurosonology technology development efforts, attempts have been made to address morphology issues and overcome technical limitations. The use of contrast agents has helped in this regard by introducing harmonics and subtraction software, which allowed better morphological studies of vessels, due to their increased signal-to-noise ratio. Having no limitations in the learning curve, in time and contrast agent techniques, and due to its high signal-to-noise ratio, MicroV has shown great potential to obtain the best morphological definition. Copyright © 2018 by the American Society of Neuroimaging.
Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M
2014-01-01
Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.
Doppler color imaging. Principles and instrumentation.
Kremkau, F W
1992-01-01
DCI acquires Doppler-shifted echoes from a cross-section of tissue scanned by an ultrasound beam. These echoes are then presented in color and superimposed on the gray-scale anatomic image of non-Doppler-shifted echoes received during the scan. The flow echoes are assigned colors according to the color map chosen. Usually red, yellow, or white indicates positive Doppler shifts (approaching flow) and blue, cyan, or white indicates negative shifts (receding flow). Green is added to indicate variance (disturbed or turbulent flow). Several pulses (the number is called the ensemble length) are needed to generate a color scan line. Linear, convex, phased, and annular arrays are used to acquire the gray-scale and color-flow information. Doppler color-flow instruments are pulsed-Doppler instruments and are subject to the same limitations, such as Doppler angle dependence and aliasing, as other Doppler instruments. Color controls include gain, TGC, map selection, variance on/off, persistence, ensemble length, color/gray priority. Nyquist limit (PRF), baseline shift, wall filter, and color window angle, location, and size. Doppler color-flow instruments generally have output intensities intermediate between those of gray-scale imaging and pulsed-Doppler duplex instruments. Although there is no known risk with the use of color-flow instruments, prudent practice dictates that they be used for medical indications and with the minimum exposure time and instrument output required to obtain the needed diagnostic information.
Hübsch, P J; Mostbeck, G; Barton, P P; Gritzmann, N; Fruehwald, F X; Schurawitzki, H; Kovarik, J
1990-02-01
One hundred one patients with renal allografts were studied by two independent observers using duplex Doppler sonography (DDS) and color-coded Doppler sonography (CCDS). In all patients, single or multiple percutaneous needle biopsies of the transplant had been performed 1 to 30 days before. In 6 patients CCDS following the biopsy demonstrated an area of combined red and blue color-coded blood flow within the renal parenchyma (n = 5) or within the sinus (n = 1); the Doppler waveform was abnormal in these areas with signals above and below the zero line indicating turbulent blood flow. Consecutive intraarterial digital subtraction angiography (DSA) revealed the presence of an arteriovenous fistula (n = 4) or of a pseudoaneurysm (n = 2). In one patient, gross hematuria with obstruction of the bladder occurred as a complication of a pseudoaneurysm within the renal sinus; the bleeding could not be stopped by embolization of the lesion and the kidney had to be removed. DDS demonstrated the lesion in only one of the six patients. Thus, CCDS is the method of choice for noninvasive detection of vascular lesions due to percutaneous biopsy.
New Doppler echocardiographic applications for the study of diastolic function
NASA Technical Reports Server (NTRS)
Garcia, M. J.; Thomas, J. D.; Klein, A. L.
1998-01-01
Doppler echocardiography is one of the most useful clinical tools for the assessment of left ventricular (LV) diastolic function. Doppler indices of LV filling and pulmonary venous (PV) flow are used not only for diagnostic purposes but also for establishing prognosis and evaluating the effect of therapeutic interventions. The utility of these indices is limited, however, by the confounding effects of different physiologic variables such as LV relaxation, compliance and filling pressure. Since alterations in these variables result in changes in Doppler indices of opposite direction, it is often difficult to determine the status of a given variable when a specific Doppler filling pattern is observed. Recently, color M-mode and tissue Doppler have provided useful insights in the study of diastolic function. These new Doppler applications have been shown to provide an accurate estimate of LV relaxation and appear to be relatively insensitive to the effects of preload compensation. This review will focus on the complementary role of color M-mode and tissue Doppler echocardiography and traditional Doppler indices of LV filling and PV flow in the assessment of diastolic function.
NASA Technical Reports Server (NTRS)
Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.
2003-01-01
BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P <.0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P <.0001) and propagation velocity (r = 0.782, P <.0001) for the most important factor predicting LV systolic and diastolic function, respectively. CONCLUSIONS: Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.
Three-dimensional power Doppler sonography in screening for carotid artery disease.
Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D
2000-01-01
Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.
Real-Time Color-Doppler Guidance of HIFU for the Selective Avoidance or Occlusion of Blood Vessels
NASA Astrophysics Data System (ADS)
Rabkin, Brian A.; Zderic, Vesna; Vaezy, Shahram
2005-03-01
High-intensity focused ultrasound (HIFU) has been shown to effectively occlude blood vessels deep within tissue. The objective of the current study was to synchronize HIFU and color-Doppler ultrasound (US) for the real-time visualization of flow within blood vessels during HIFU treatment. The excitation of the HIFU was synchronized with the color-Doppler imager by collecting the excitation pulses of one of the elements of either a curved array intracavitary (C 9-5) or an intraoperative (CL 10-5) imaging probe. The collected excitation pulse was converted into a TTL-high pulse, which was delayed and gated to time the excitation duration and location of the HIFU pulse with respect to each imaging frame. The single pulse was used to drive a 3.2 MHz concave HIFU transducer (focal length of 3.5 cm, f-number 1) while the US imager was not collecting RF signals from the treatment region of the US image. The feasibility of the system was demonstrated in vivo by the selective ablation of tissue adjacent to, or the occlusion of, large vessels (including the femoral artery) both transcutaneously and interoperatively in the rabbit and pig. For the occlusion of vessels, the HIFU focus was placed immediately distal (with respect to the transducer) to the vessel at a depth of 2-2.5 cm. HIFU was applied at in situ intensities of 1000-2000 W/cm2, at a duty cycle of 50-75%, and a HIFU pulse repetition frequency (set by the US image frame rate) of 6-18 Hz. During each HIFU exposure, the HIFU pulse resulted in color interference bands running vertically within the color-Doppler window. Through the synchronization of the US imager with the HIFU excitation, the location and duration of the interference bands were set outside the treatment region within each image frame. This provided the operator with a clear view of the HIFU treatment site during therapy. Gross assessment showed necrosis of the tissue surrounding the HIFU treated vessel and occlusion of vessels up to 4 mm in diameter after a 30 s HIFU exposure. We have developed a method of synchronizing pulsed HIFU with color-Doppler US imaging for the real-time visualization of flow within blood vessels during HIFU therapy. This provides a means of guiding HIFU therapy for the detection and occlusion of deep vessels, or the selective ablation of tissue surrounding the vessels without vascular occlusion.
NASA Astrophysics Data System (ADS)
Jiang, Yan; Harrison, Tyler; Forbrich, Alex; Zemp, Roger J.
2011-03-01
The metabolic rate of oxygen consumption (MRO2) quantifies tissue metabolism, which is important for diagnosis of many diseases. For a single vessel model, the MRO2 can be estimated in terms of the mean flow velocity, vessel crosssectional area, total concentration of hemoglobin (CHB), and the difference between the oxygen saturation (sO2) of blood flowing into and out of the tissue region. In this work, we would like to show the feasibility to estimate MRO2 with our combined photoacoustic and high-frequency ultrasound imaging system. This system uses a swept-scan 25-MHz ultrasound transducer with confocal dark-field laser illumination optics. A pulse-sequencer enables ultrasonic and laser pulses to be interlaced so that photoacoustic and Doppler ultrasound images are co-registered. Since the mean flow velocity can be measured by color Doppler ultrasound, the vessel cross-sectional area can be measured by power Doppler or photoacoustic imaging, and multi-wavelength photoacoustic methods can be used to estimate sO2 and CHB, all of these parameters necessary for MRO2 estimation can be provided by our system. Experiments have been performed on flow phantoms to generate co-registered color Doppler and photoacoustic images. To verify the sO2 estimation, two ink samples (red and blue) were mixed in various concentration ratios to mimic different levels of sO2, and the result shows a good match between the calculated concentration ratios and actual values.
Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.
Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen
2016-03-01
Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.
Bubble-induced Color Doppler Feedback for Histotripsy Tissue Fractionation
Miller, Ryan M.; Zhang, Xi; Maxwell, Adam; Cain, Charles; Xu, Zhen
2016-01-01
Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with 2-cycle histotripsy pulses at > 30 MPa using a 500 kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression. PMID:26863659
NASA Astrophysics Data System (ADS)
Potlov, A. Yu.; Frolov, S. V.; Proskurin, S. G.
2018-04-01
The method of Doppler color mapping of one specific (previously chosen) velocity in a turbulent flow inside biological tissues using optical coherence tomography is described. The key features of the presented method are: the raw data are separated into three parts, corresponding to the unmoving biological tissue, the positively and negatively directed biological fluid flows; the further independent signal processing procedure yields the structure image and two images of the chosen velocity, which are then normalised, encoded and joined. The described method can be used to obtain in real time the anatomical maps of the chosen velocities in normal and pathological states. The described method can be applied not only in optical coherence tomography, but also in endoscopic and Doppler ultrasonic medical imaging systems.
Suzuki, Y; Kambara, H; Kadota, K; Tamaki, S; Yamazato, A; Nohara, R; Osakada, G; Kawai, C
1985-08-01
To evaluate the noninvasive detection of shunt flow using a newly developed real-time 2-dimensional color-coded Doppler flow imaging system (D-2DE), 20 patients were examined, including 10 with secundum atrial septal defect (ASD) and 10 control subjects. These results were compared with contrast 2-dimensional echocardiography (C-2DE). Doppler 2DE displayed the blood flow toward the transducer as red and the blood flow away from the transducer as blue in 8 shades, each shade adding green according to the degree of variance in Doppler frequency. In the patients with ASD, D-2DE clearly visualized left-to-right shunt flow in 7 of 10 patients. In 5 of these 7 patients, C-2DE showed a negative contrast effect in the same area of the right atrium. Thus, D-2DE increased the sensitivity over C-2DE for detecting left-to-right shunt flow (from 50% to 70%). However, the specificity was slightly less in D-2DE (90%) than C-2DE (100%). Doppler 2DE could not visualize right-to-left shunt flow in all patients with ASD, though C-2DE showed a positive contrast effect in the left-sided heart in 9 of 10 patients with ASD. Thus, D-2DE is clinically useful for detecting left-to-right shunt flow in patients with ASD.
Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis
Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami
2013-01-01
AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754
Etiology of congenital hypothyroidism using thyroglobulin and ultrasound combination.
Beltrão, Cristine B; Juliano, Adriana G; Chammas, Maria C; Watanabe, Tomoco; Sapienza, Marcelo T; Marui, Suemi
2010-01-01
Methods currently employed to establish the etiology of congenital hypothyroidism include thyroid ultrasound and scintigraphic exams. Thyroglobulin is a protein almost exclusively secreted by thyroid tissue and indirectly reflects the amount of follicular cells. Even though thyroglobulin is easy to measure, it has been not frequently used because of discordant results to distinguish mainly athyreosis and ectopy (dysgenesis). Knowing the differences in inheritance and prognosis of thyroid dysgenesis and dyshormonogenesis, it is important to define the etiology of CH, combining tools that are easy, fast and available in most medical centers. Our objective was to evaluate and compare color Doppler ultrasound and serum thyroglobulin with radionuclide scan to define the etiology of congenital hypothyroidism. We evaluated 38 children above 3 years-old off-treatment that performed serum thyroglobulin by immunofluorometric assay, color Doppler ultrasound and radionuclide study. On color Doppler ultrasound, 11 patients had athyreosis, 5 ectopic glands, being 1 associated to hemiagenesis. Twenty one had topic thyroid (3 goiters, 10 normal, 8 hypoplastic). Hemiagenesis and cystic lesion were not revealed by radionuclide scan. We observed substantial agreement between color Doppler ultrasound and radionuclide scan (kappa=0.745, p<0.0001). Serum thyroglobulin in athyreosis ranged from <1.0 to 18.7 micro g/L. Patients with ectopic glands showed wider thyroglobulin range (4.5 to 123 micro g/L, median 28.4 micro g/L). Only one patient showed thyroglobulin deficiency. By using color Doppler ultrasound and serum thyroglobulin levels as valuable combined tools, we established the etiology of congenital hypothyroidism limiting excessive and harmful exams in children, like radionuclide scan.
Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola
2005-01-01
Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.
Shear Wave Imaging of Breast Tissue by Color Doppler Shear Wave Elastography.
Yamakoshi, Yoshiki; Nakajima, Takahito; Kasahara, Toshihiro; Yamazaki, Mayuko; Koda, Ren; Sunaguchi, Naoki
2017-02-01
Shear wave elastography is a distinctive method to access the viscoelastic characteristic of the soft tissue that is difficult to obtain by other imaging modalities. This paper proposes a novel shear wave elastography [color Doppler shear wave imaging (CD SWI)] for breast tissue. Continuous shear wave is produced by a small lightweight actuator, which is attached to the tissue surface. Shear wave wavefront that propagates in tissue is reconstructed as a binary pattern that consists of zero and the maximum flow velocities on color flow image (CFI). Neither any modifications of the ultrasound color flow imaging instrument nor a high frame rate ultrasound imaging instrument is required to obtain the shear wave wavefront map. However, two conditions of shear wave displacement amplitude and shear wave frequency are needed to obtain the map. However, these conditions are not severe restrictions in breast imaging. This is because the minimum displacement amplitude is [Formula: see text] for an ultrasonic wave frequency of 12 MHz and the shear wave frequency is available from several frequencies suited for breast imaging. Fourier analysis along time axis suppresses clutter noise in CFI. A directional filter extracts shear wave, which propagates in the forward direction. Several maps, such as shear wave phase, velocity, and propagation maps, are reconstructed by CD SWI. The accuracy of shear wave velocity measurement is evaluated for homogeneous agar gel phantom by comparing with the acoustic radiation force impulse method. The experimental results for breast tissue are shown for a shear wave frequency of 296.6 Hz.
Sripathi, Smiti; Mahajan, Abhishek
2013-09-01
To analyze qualitative and quantitative parameters of lung tumors by color Doppler sonography, determine the role of color Doppler sonography in predicting chest wall invasion by lung tumors using spectral waveform analysis, and compare color Doppler sonography and computed tomography (CT) for predicting chest wall invasion by lung tumors. Between March and September 2007, 55 patients with pleuropulmonary lesions on chest radiography were assessed by grayscale and color Doppler sonography for chest wall invasion. Four patients were excluded from the study because of poor acoustic windows. Quantitative and qualitative sonographic examinations of the lesions were performed using grayscale and color Doppler imaging. The correlation between the color Doppler and CT findings was determined, and the final outcomes were correlated with the histopathologic findings. Of a total of 51 lesions, 32 were malignant. Vascularity was present on color Doppler sonography in 28 lesions, and chest wall invasion was documented in 22 cases. Computed tomography was performed in 24 of 28 evaluable malignant lesions, and the findings were correlated with the color Doppler findings for chest wall invasion. Of the 24 patients who underwent CT, 19 showed chest wall invasion. The correlation between the color Doppler and CT findings revealed that color Doppler sonography had sensitivity of 95.6% and specificity of 100% for assessing chest wall invasion, whereas CT had sensitivity of 85.7% and specificity of 66.7%. Combined qualitative and quantitative color Doppler sonography can predict chest wall invasion by lung tumors with better sensitivity and specificity than CT. Although surgery is the reference standard, color Doppler sonography is a readily available, affordable, and noninvasive in vivo diagnostic imaging modality that is complementary to CT and magnetic resonance imaging for lung cancer staging.
Gorcsan, John; Abraham, Theodore; Agler, Deborah A; Bax, Jeroen J; Derumeaux, Genevieve; Grimm, Richard A; Martin, Randy; Steinberg, Jonathan S; Sutton, Martin St John; Yu, Cheuk-Man
2008-03-01
Echocardiography plays an evolving and important role in the care of heart failure patients treated with biventricular pacing, or cardiac resynchronization therapy (CRT). Numerous recent published reports have utilized echocardiographic techniques to potentially aide in patient selection for CRT prior to implantation and to optimized device settings afterwards. However, no ideal approach has yet been found. This consensus report evaluates the contemporary applications of echocardiography for CRT including relative strengths and technical limitations of several techniques and proposes guidelines regarding current and possible future clinical applications. Principal methods advised to qualify abnormalities in regional ventricular activation, known as dyssynchrony, include longitudinal velocities by color-coded tissue Doppler and the difference in left ventricular to right ventricular ejection using routine pulsed Doppler, or interventricular mechanical delay. Supplemental measures of radial dynamics which may be of additive value include septal-to-posterior wall delay using M-mode in patients with non-ischemic disease with technically high quality data, or using speckle tracking radial strain. A simplified post-CRT screening for atrioventricular optimization using Doppler mitral inflow velocities is also proposed. Since this is rapidly changing field with new information being added frequently, future modification and refinements in approach are anticipated to continue.
NASA Astrophysics Data System (ADS)
Yazdanfar, Siavash; Kulkarni, Manish D.; Wong, Richard C. K.; Sivak, Michael J., Jr.; Willis, Joseph; Barton, Jennifer K.; Welch, Ashley J.; Izatt, Joseph A.
1998-04-01
A recently developed modality for blood flow measurement holds high promise in the management of bleeding ulcers. Color Doppler optical coherence tomography (CDOCT) uses low- coherence interferometry and digital signal processing to obtain precise localization of tissue microstructure simultaneous with bi-directional quantitation of blood flow. We discuss CDOCT as a diagnostic tool in the management of bleeding gastrointestinal lesions. Common treatments for bleeding ulcers include local injection of a vasoconstrictor, coagulation of blood via thermal contact or laser treatment, and necrosis of surrounding tissue with a sclerosant. We implemented these procedures in a rat dorsal skin flap model, and acquired CDOCT images before and after treatment. In these studies, CDOCT succeeded in identifying cessation of flow before it could be determined visually. Hence, we demonstrate the diagnostic capabilities of CDOCT in the regulation of bleeding in micron-scale vessels.
A New Active Cavitation Mapping Technique for Pulsed HIFU Applications – Bubble Doppler
Li, Tong; Khokhlova, Tatiana; Sapozhnikov, Oleg; Hwang, Joo Ha; Sapozhnikov, Oleg; O’Donnell, Matthew
2015-01-01
In this work, a new active cavitation mapping technique for pulsed high-intensity focused ultrasound (pHIFU) applications termed bubble Doppler is proposed and its feasibility tested in tissue-mimicking gel phantoms. pHIFU therapy uses short pulses, delivered at low pulse repetition frequency, to cause transient bubble activity that has been shown to enhance drug and gene delivery to tissues. The current gold standard for detecting and monitoring cavitation activity during pHIFU treatments is passive cavitation detection (PCD), which provides minimal information on the spatial distribution of the bubbles. B-mode imaging can detect hyperecho formation, but has very limited sensitivity, especially to small, transient microbubbles. The bubble Doppler method proposed here is based on a fusion of the adaptations of three Doppler techniques that had been previously developed for imaging of ultrasound contrast agents – color Doppler, pulse inversion Doppler, and decorrelation Doppler. Doppler ensemble pulses were interleaved with therapeutic pHIFU pulses using three different pulse sequences and standard Doppler processing was applied to the received echoes. The information yielded by each of the techniques on the distribution and characteristics of pHIFU-induced cavitation bubbles was evaluated separately, and found to be complementary. The unified approach - bubble Doppler – was then proposed to both spatially map the presence of transient bubbles and to estimate their sizes and the degree of nonlinearity. PMID:25265178
Ultrasonically Encoded Photoacoustic Flowgraphy in Biological Tissue
NASA Astrophysics Data System (ADS)
Wang, Lidai; Xia, Jun; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-11-01
Blood flow speed is an important functional parameter. Doppler ultrasound flowmetry lacks sufficient sensitivity to slow blood flow (several to tens of millimeters per second) in deep tissue. To address this challenge, we developed ultrasonically encoded photoacoustic flowgraphy combining ultrasonic thermal tagging with photoacoustic imaging. Focused ultrasound generates a confined heat source in acoustically absorptive fluid. Thermal waves propagate with the flow and are directly visualized in pseudo color using photoacoustic computed tomography. The Doppler shift is employed to calculate the flow speed. This method requires only acoustic and optical absorption, and thus is applicable to continuous fluid. A blood flow speed as low as 0.24mm·s-1 was successfully measured. Deep blood flow imaging was experimentally demonstrated under 5-mm-thick chicken breast tissue.
Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.
Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P
1995-01-01
Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.
Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin; Ellegaard, Karen; D'Agostino, Maria Antonietta; Iagnocco, Annamaria; Naredo, Esperanza; Balint, Peter; Wakefield, Richard J; Torp-Pedersen, Arendse; Terslev, Lene
2015-02-01
To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. Six different types of ultrasound machines were used. On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. Power Doppler was more sensitive on half of the machines, whereas color Doppler was more sensitive on the other half, using both factory settings and study settings. There was an average increase in Doppler sensitivity, despite modality, of 78% when study settings were applied. Over the 6 machines, 2 Doppler modalities, and 2 settings, the grades for each of 7 of the patients varied between 0 and 3, while the grades for each of the other 4 patients varied between 0 and 2. The effect of using different machines, Doppler modalities, and settings has a considerable influence on the quantification of inflammation by ultrasound in RA patients, and this must be taken into account in multicenter studies. Copyright © 2015 by the American College of Rheumatology.
Causes of Ultrasound Doppler Twinkling Artifact
NASA Astrophysics Data System (ADS)
Leonov, D. V.; Kulberg, N. S.; Gromov, A. I.; Morozov, S. P.; Kim, S. Yu.
2018-01-01
Ultrasound Doppler twinkling artifact is analyzed. It usually appears as a frequent color alteration in the region of hyperechoic objects. Its noiselike spectrum can also be seen in spectral Doppler mode. Physicians use twinkling artifact as a clinical sign for kidney-stone and soft-tissue calculi detection. The advantageous peculiarity of this study is that the experiments were conducted utilizing raw signals obtained from a custom ultrasonic machine and a specially developed phantom. The phantom contained specimens with known qualities, allowing for reproducible and predictable results. The experiments revealed evidence for two physical causes of twinkling artifact, which were associated with two unique Doppler signals. The research laid the foundation for the new reflected-signal model introduced and used throughout this paper.
Fukuda, Hiroyuki; Numata, Kazushi; Nozaki, Akito; Kondo, Masaaki; Morimoto, Manabu; Maeda, Shin; Tanaka, Katsuaki; Ohto, Masao; Ito, Ryu; Ishibashi, Yoshiharu; Oshima, Noriyoshi; Ito, Ayao; Zhu, Hui; Wang, Zhi-Biao
2013-12-01
We evaluated the usefulness of color Doppler flow imaging to compensate for the inadequate resolution of the ultrasound (US) monitoring during high-intensity focused ultrasound (HIFU) for the treatment of hepatocellular carcinoma (HCC). US-guided HIFU ablation assisted using color Doppler flow imaging was performed in 11 patients with small HCC (<3 lesions, <3 cm in diameter). The HIFU system (Chongqing Haifu Tech) was used under US guidance. Color Doppler sonographic studies were performed using an HIFU 6150S US imaging unit system and a 2.7-MHz electronic convex probe. The color Doppler images were used because of the influence of multi-reflections and the emergence of hyperecho. In 1 of the 11 patients, multi-reflections were responsible for the poor visualization of the tumor. In 10 cases, the tumor was poorly visualized because of the emergence of a hyperecho. In these cases, the ability to identify the original tumor location on the monitor by referencing the color Doppler images of the portal vein and the hepatic vein was very useful. HIFU treatments were successfully performed in all 11 patients with the assistance of color Doppler imaging. Color Doppler imaging is useful for the treatment of HCC using HIFU, compensating for the occasionally poor visualization provided by B-mode conventional US imaging.
Colour flow and motion imaging.
Evans, D H
2010-01-01
Colour flow imaging (CFI) is an ultrasound imaging technique whereby colour-coded maps of tissue velocity are superimposed on grey-scale pulse-echo images of tissue anatomy. The most widespread use of the method is to image the movement of blood through arteries and veins, but it may also be used to image the motion of solid tissue. The production of velocity information is technically more demanding than the production of the anatomical information, partly because the target of interest is often blood, which backscatters significantly less power than solid tissues, and partly because several transmit-receive cycles are necessary for each velocity estimate. This review first describes the various components of basic CFI systems necessary to generate the velocity information and to combine it with anatomical information. It then describes a number of variations on the basic autocorrelation technique, including cross-correlation-based techniques, power Doppler, Doppler tissue imaging, and three-dimensional (3D) Doppler imaging. Finally, a number of limitations of current techniques and some potential solutions are reviewed.
Pirat, Bahar; Yildirir, Aylin; Simşek, Vahide; Ozin, Bülent; Müderrisoğlu, Haldun
2008-03-01
We investigated the effect of increased preload through postural changes (leg lifting) on tissue Doppler parameters in patients with and without coronary artery disease (CAD). The study included 42 patients who were scheduled for coronary angiography. All the patients underwent standard two-dimensional, color Doppler and tissue Doppler echocardiography before coronary angiography. Tissue Doppler imaging was performed from septal and lateral mitral annuluses at baseline and during 45 degrees leg lifting followed by two-minute stabilization. Patients were grouped based on coronary angiography findings: those having stenosis greater than 70% were considered to have CAD and those with normal coronary arteries comprised the control group. Echocardiography measurements were compared between the two groups. Angiography showed normal coronary arteries or border irregularities in 22 patients and CAD in 20 patients. The two groups were similar with regard to demographic data and ejection fractions, except for male preponderance in the CAD group. Compared with the control group, patients with CAD exhibited a significantly lower isovolumic acceleration rate (IVA) at the lateral (p=0.007) and septal (p=0.03) mitral annuluses. In the control group, leg lifting resulted in increased systolic velocity (S) compared with baseline at the lateral (p=0.009) and septal (p=0.01) annuluses, whereas S wave augmentation was only significant at the septal annulus (p=0.009) in patients with CAD. No significant change was observed in IVA following leg lifting in both groups. Preload alteration induced by leg lifting resulted in similar changes in tissue Doppler parameters in patients with and without CAD, except for blunted augmentation of S wave at the lateral annulus in CAD. Detection of decreased IVA at baseline may be a useful finding for CAD.
Staggered Multiple-PRF Ultrafast Color Doppler.
Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien
2016-06-01
Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.
Oebisu, Naoto; Hoshi, Manabu; Ieguchi, Makoto; Takada, Jun; Iwai, Tadashi; Ohsawa, Masahiko; Nakamura, Hiroaki
2014-10-01
Resolution of ultrasonography (US) has undergone marked development. Additionally, a new-generation contrast medium (Sonazoid) used for US is newly available. Contrast-enhanced US has been widely used for evaluating several types of cancer. In the present study, we evaluated the ability of color Doppler US (CDUS) and Sonazoid to differentiate between benign and malignant soft tissue tumors. A total of 180 patients (87 male, 93 female) were enrolled in the present study. The patient ages ranged from 1 to 91 years (mean 58.1±20.0 years). The maximum size, depth, tumor margins, shape, echogenicity and textural pattern were measured on gray-scale images. CDUS was used to evaluate the intratumoral blood flow with and without Sonazoid. Peak systolic flow velocity (Vp), mean flow velocity (Vm), resistivity index (RI) and pulsatility index (PI) of each detected intratumoral artery were automatically calculated with power Doppler US (PDUS). The present study included 118 benign and 62 malignant tumors. Statistical significances were found in size, depth, tumor margin and textural pattern but not in shape or echogenicity on gray-scale images. Before Sonazoid injection, CDUS findings showed 55% sensitivity, 77% specificity and 69% accuracy, whereas contrast-enhanced CDUS showed 87% sensitivity, 68% specificity and 74% accuracy. There were no statistically significant differences between malignant and benign tumors regarding the mean Vp, Vm, RI and PI values determined on PDUS. In conclusion, contrast-enhanced CDUS proved to be a reliable diagnostic tool for detecting malignant potential in soft tissue tumors.
Hyperemia in plantar fasciitis determined by power Doppler ultrasound.
McMillan, Andrew M; Landorf, Karl B; Gregg, Julie M; De Luca, Jason; Cotchett, Matthew P; Menz, Hylton B
2013-12-01
Cross-sectional observational study. To investigate the presence of soft tissue hyperemia in plantar fasciitis with power Doppler ultrasound. Localized hyperemia is an established feature of tendinopathy, suggesting that neurovascular in-growth may contribute to tendon-associated pain in some patients. The presence of abnormal soft tissue vascularity can be assessed with Doppler ultrasound, and a positive finding can assist with targeted treatment plans. However, very little is known regarding the presence of hyperemia in plantar fasciitis and the ability of routine Doppler ultrasound to identify vascular in-growth in the plantar fascia near its proximal insertion. This observational study included 30 participants with plantar fasciitis unrelated to systemic disease and 30 age- and sex-matched controls. Ultrasound examination was performed with a 13- to 5-MHz linear transducer, and power Doppler images were assessed by 2 blinded investigators. Hyperemia of the plantar fascia was present in 8 of 30 participants with plantar fasciitis and in 2 of 30 controls. The between-group difference for hyperemia, using a 4-point scale, was statistically significant, with participants with plantar fasciitis showing increased Doppler ultrasound signal compared to controls (Mann-Whitney U, P = .03). However, the majority of participants with plantar fasciitis with evidence of hyperemia demonstrated very mild color changes, and only 3 were found to have moderate or marked hyperemia. Mild hyperemia can occur with plantar fasciitis, but most individuals will not exhibit greater soft tissue vascularity when assessed with routine Doppler ultrasound. Clinicians treating plantar fasciitis should not consider a positive Doppler signal as essential for diagnosis of the condition but, rather, as a feature that may help to refine the treatment plan for an individual patient.
Detection of cavernous transformation of the portal vein by contrast-enhanced ultrasound.
Hwang, Misun; Thimm, Matthew A; Guerrerio, Anthony L
2018-06-01
Cavernous transformation of the portal vein can be missed on color Doppler exam or arterial phase cross-sectional imaging due to their slow flow and delayed enhancement. Contrast-enhanced ultrasound (CEUS) offers many advantages over other imaging techniques and can be used to successfully detect cavernous transformations of the portal vein. A 10-month-old female was followed for repeat episodes of hematemesis. Computed tomography angiography (CTA) and magnetic resonance arteriogram (MRA) and portal venography were performed. Color Doppler exam of the portal vein was performed followed by administration of Lumason, a microbubble US contrast agent. Magnetic resonance arteriogram, CTA, and color Doppler exam at the time of initial presentation was unremarkable without obvious vascular malformation within the limits of motion degraded exam. At 8-month follow-up, esophagogastroduodenoscopy revealed a vascular malformation in the distal esophagus which was sclerosed. At 6 month after sclerosis of the lesion, portal venography revealed occlusion of the portal vein with extensive collateralization. Color Doppler revealed subtle hyperarterialization and periportal collaterals. CEUS following color Doppler exam demonstrated extensive enhancement of periportal collaterals. Repeat color Doppler after contrast administration demonstrated extensive Doppler signal in the collateral vessels, suggestive of cavernous transformation. We describe a case of cavernous transformation of the portal vein missed on initial color Doppler, CTA and MRA, but detected with contrast-enhanced ultrasound technique.
Animating a Human Body Mesh with Maya for Doppler Signature Computer Modeling
2009-06-01
three color-coded transformation tools attached to the AK47 mesh used to create the man with weapon model. Red, green, and blue correspond to the x-, y...animation scenario, the human moves in a natural walking motion cycle (figure 9). In the other two, the walking human carries an AK47 rifle in the port
Ishii, M; Jones, M; Shiota, T; Yamada, I; Sinclair, B; Heinrich, R S; Yoganathan, A P; Sahn, D J
1998-11-01
The purpose of our study was to determine the temporal variability of regurgitant color Doppler jet areas and the width of the color Doppler imaged vena contracta for evaluating the severity of aortic regurgitation. Twenty-nine hemodynamically different states were obtained pharmacologically in 8 sheep 20 weeks after surgery to produce aortic regurgitation. Aortic regurgitation was quantified by peak and mean regurgitant flow rates, regurgitant stroke volumes, and regurgitant fractions determined using pulmonary and aortic electromagnetic flow probes and meters balanced against each other. The regurgitant jet areas and the widths of color Doppler imaged vena contracta were measured at 4 different times during diastole to determine the temporal variability of this parameter. When measured at 4 different temporal points in diastole, a significant change was observed in the size of the color Doppler imaged regurgitant jet (percent of difference: from 31.1% to 904%; 233% +/- 245%). Simple linear regression analysis between each color jet area at 4 different periods in diastole and flow meter-based severity of the aortic regurgitation showed only weak correlation (0.23 < r < 0.49). In contrast, for most conditions only a slight change was observed in the width of the color Doppler imaged vena contracta during the diastolic regurgitant period (percent of difference, vena contracta: from 2.4% to 12.9%, 5.8% +/- 3.2%). In addition, for each period the width of the color Doppler imaged vena contracta at the 4 different time periods in diastole correlated quite strongly with volumetric measures of the severity of aortic regurgitation (0.81 < r < 0.90) and with the instantaneous flow rate for the corresponding period (0.85 < r < 0.87). Color Doppler imaged vena contracta may provide a simple, practical, and accurate method for quantifying aortic regurgitation, even when using a single frame color Doppler flow mapping image.
NASA Technical Reports Server (NTRS)
Armstrong, G.; Cardon, L.; Vilkomerson, D.; Lipson, D.; Wong, J.; Rodriguez, L. L.; Thomas, J. D.; Griffin, B. P.
2001-01-01
This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.
Sureshkumar, Sathasivam; Vignesh, Narayan; Venkatachalam, J; Vijayakumar, Chellappa; Sudharsanan, Sundaramurthi
2018-01-05
Background The color Doppler, a better investigation to identify the perforators objectively has replaced the clinical examination for the same. However, this has led to a significant number of negative explorations and cosmetic disfigurement. Objective To compare the efficacy of the clinical tests combined with the color Doppler versus color Doppler alone to identify the perforator incompetence during the surgery for primary varicose veins of the lower limb. Methods This was a prospective analytical study, including 61 lower limb varicose vein patients who belonged to the Clinical-Etiology-Anatomy-Pathophysiology (CEAP) class four-six, planned for the surgical treatment for perforator incompetence, excluding those requiring additional vascular or nonvascular procedure, recurrent varicose veins and those who had injection sclerotherapy prior to the surgery. The clinical tests, including Trendelenburg's test, multiple tourniquet tests and, the Fegan's tests were performed and incompetent perforators were marked on a template as 'C' to indicate the clinically positive perforator incompetence. The patients were then examined with the color Doppler ultrasound and the pathological incompetent perforators were marked as 'D'. The surgical management of the perforator incompetence was done by stab ligation. The incision was made in the color Doppler 'D' marked sites as it has been the standard protocol. The number of incompetent perforators identified during the surgical exploration were categorized as 'D' positive or 'C' and 'D' positive and were recorded in the specified proforma. Results It was found that the mean number of the perforator incompetence identified by the color Doppler alone was 8.2 whereas during the surgery, only a mean of six perforators was identified, leading to 20 unnecessary explorations per 10 patients (8.2 vs. 6; mean difference 2.229; P <0.001). The mean number of the perforator incompetence identified by the color Doppler combined with the clinical tests was 4.5 and during the surgery, a mean of four perforators was identified (4.5 vs. 4; mean difference 0.377; P <0.001). The color Doppler combined with the clinical examination lead to only four unnecessary explorations per 10 patients. Conclusion A combination of both the clinical tests and the color Doppler ultrasound has a higher accuracy in detecting perforator incompetence and can reduce the number of negative explorations by the rate of 16 unnecessary explorations per 10 patients.
Dzięcioł, Michał; Stańczyk, Ewa; Noszczyk-Nowak, Agnieszka; Michlik, Katarzyna; Kozdrowski, Roland; Niżański, Wojciech; Pasławskab, Urszula; Mrowiec, Jacek; Twardoń, Jan
2014-03-01
The aim of the study was to evaluate the influence of the Sildenafil citrate on the blood flow in the uterus of cows during dioestrus. Uterine blood flow was examined in five, healthy, adult cows. Between day 6-8 of the ovarian cycle, each cow received 200mg of sildenafil diluted in 10ml of warm saline into the body of the uterus. Analysis of the blood pressure, ECG and the maximum velocity in m/s (V max) in the aorta was performed and selected parameters of the blood flow (PI, pulsatile index; RI, resistance index; SPV, systolic peak velocity; EDV, end diastolic velocity; FVI, flow velocity integral; SV/DV, systolic peak velocity: end-diastolic velocity ratio) were measured in the uterine artery (Arteria uterine) before and after sildenafil infusion. In addition, Color Doppler examination of the uterine wall perfusion was analyzed. A significant decrease of values of PI and SV/DV ratio as well as an increase of end diastolic velocity and time averaged maximum velocity was noted. With the use of color coded sonography, the increased intensity of the blood flow in the uterine wall was observed. It was concluded that intrauterine administration of sildenafil during dioestrus can increase uterine tissue perfusion. Copyright © 2013 Elsevier GmbH. All rights reserved.
Prostate: techniques, results, and potential applications of color Doppler US scanning.
Rifkin, M D; Sudakoff, G S; Alexander, A A
1993-02-01
Color Doppler ultrasound (US) scanning and conventional endorectal gray-scale US of the prostate were performed in 619 patients. Pathologic correlation was available in all cases after US-guided transrectal biopsy. There were 132 cancers in 121 men, 13 foci of atypia in 10 men, 33 foci of inflammation in 31 men, and 469 benign lesions in 457 men. Two hundred seventy patients with abnormal areas of flow identified at color Doppler scanning also underwent spectral waveform analysis of the area of potential concern. No statistical difference in the mean resistive indexes was identified in any patient (P = .25; Scheffe F test, analysis of variance). All malignant lesions had abnormalities demonstrated at gray-scale US and/or focal or diffuse abnormal flow demonstrated at color Doppler scanning. Of the 132 cancers, 123 (93%) had corresponding gray-scale abnormalities and 114 (86%) demonstrated abnormal flow at color Doppler imaging. Nine of the 132 cancers (7%) had no obviously identifiable abnormality at gray-scale scanning but had distinctly abnormal flow at color Doppler scanning. Abnormal findings at color scanning without abnormal findings at gray-scale scanning occurred in eight of the 33 cases of inflammatory foci (24%) and in 24 of the 469 (5%) benign lesions.
Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions
Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati
2011-01-01
Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940
Temporal enhancement of two-dimensional color doppler echocardiography
NASA Astrophysics Data System (ADS)
Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.
2016-03-01
Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.
Color doppler in clinical cardiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duncan, W.J.
1987-01-01
A presentation of color doppler, which enables physicians to pinpoint problems and develop effective treatment. State-of-the-art illustrations and layout, with color images and explanatory text are included.
Zierler, R Eugene; Leotta, Daniel F; Sansom, Kurt; Aliseda, Alberto; Anderson, Mark D; Sheehan, Florence H
2016-07-01
Duplex ultrasound scanning with B-mode imaging and both color Doppler and Doppler spectral waveforms is relied upon for diagnosis of vascular pathology and selection of patients for further evaluation and treatment. In most duplex ultrasound applications, classification of disease severity is based primarily on alterations in blood flow velocities, particularly the peak systolic velocity (PSV) obtained from Doppler spectral waveforms. We developed a duplex ultrasound simulator for training and assessment of scanning skills. Duplex ultrasound cases were prepared from 2-dimensional (2D) images of normal and stenotic carotid arteries by reconstructing the common carotid, internal carotid, and external carotid arteries in 3 dimensions and computationally simulating blood flow velocity fields within the lumen. The simulator displays a 2D B-mode image corresponding to transducer position on a mannequin, overlaid by color coding of velocity data. A spectral waveform is generated according to examiner-defined settings (depth and size of the Doppler sample volume, beam steering, Doppler beam angle, and pulse repetition frequency or scale). The accuracy of the simulator was assessed by comparing the PSV measured from the spectral waveforms with the true PSV which was derived from the computational flow model based on the size and location of the sample volume within the artery. Three expert examiners made a total of 36 carotid artery PSV measurements based on the simulated cases. The PSV measured by the examiners deviated from true PSV by 8% ± 5% (N = 36). The deviation in PSV did not differ significantly between artery segments, normal and stenotic arteries, or examiners. To our knowledge, this is the first simulation of duplex ultrasound that can create and display real-time color Doppler images and Doppler spectral waveforms. The results demonstrate that an examiner can measure PSV from the spectral waveforms using the settings on the simulator with a mean absolute error in the velocity measurement of less than 10%. With the addition of cases with a range of pathologies, this duplex ultrasound simulator will be a useful tool for training health-care providers in vascular ultrasound applications and for assessing their skills in an objective and quantitative manner. © The Author(s) 2016.
Vignesh, Narayan; Venkatachalam, J; Vijayakumar, Chellappa; Sudharsanan, Sundaramurthi
2018-01-01
Background The color Doppler, a better investigation to identify the perforators objectively has replaced the clinical examination for the same. However, this has led to a significant number of negative explorations and cosmetic disfigurement. Objective To compare the efficacy of the clinical tests combined with the color Doppler versus color Doppler alone to identify the perforator incompetence during the surgery for primary varicose veins of the lower limb. Methods This was a prospective analytical study, including 61 lower limb varicose vein patients who belonged to the Clinical-Etiology-Anatomy-Pathophysiology (CEAP) class four-six, planned for the surgical treatment for perforator incompetence, excluding those requiring additional vascular or nonvascular procedure, recurrent varicose veins and those who had injection sclerotherapy prior to the surgery. The clinical tests, including Trendelenburg’s test, multiple tourniquet tests and, the Fegan’s tests were performed and incompetent perforators were marked on a template as ‘C’ to indicate the clinically positive perforator incompetence. The patients were then examined with the color Doppler ultrasound and the pathological incompetent perforators were marked as ‘D’. The surgical management of the perforator incompetence was done by stab ligation. The incision was made in the color Doppler ‘D’ marked sites as it has been the standard protocol. The number of incompetent perforators identified during the surgical exploration were categorized as ‘D’ positive or ’C’ and ‘D’ positive and were recorded in the specified proforma. Results It was found that the mean number of the perforator incompetence identified by the color Doppler alone was 8.2 whereas during the surgery, only a mean of six perforators was identified, leading to 20 unnecessary explorations per 10 patients (8.2 vs. 6; mean difference 2.229; P <0.001). The mean number of the perforator incompetence identified by the color Doppler combined with the clinical tests was 4.5 and during the surgery, a mean of four perforators was identified (4.5 vs. 4; mean difference 0.377; P <0.001). The color Doppler combined with the clinical examination lead to only four unnecessary explorations per 10 patients. Conclusion A combination of both the clinical tests and the color Doppler ultrasound has a higher accuracy in detecting perforator incompetence and can reduce the number of negative explorations by the rate of 16 unnecessary explorations per 10 patients. PMID:29531879
Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren
2006-12-01
The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced achillodynia and habitually played with a degree of pain that demanded medication. The self-reported pain was associated with increased intratendinous color Doppler flow in the nondominant Achilles tendon. Doppler flow was found in most players before and in all players after the match and therefore may in part be a physiological response to activity.
Optimized doppler optical coherence tomography for choroidal capillary vasculature imaging
NASA Astrophysics Data System (ADS)
Liu, Gangjun; Qi, Wenjuan; Yu, Lingfeng; Chen, Zhongping
2011-03-01
In this paper, we analyzed the retinal and choroidal blood vasculature in the posterior segment of the human eye with optimized color Doppler and Doppler variance optical coherence tomography. Depth-resolved structure, color Doppler and Doppler variance images were compared. Blood vessels down to capillary level were able to be obtained with the optimized optical coherence color Doppler and Doppler variance method. For in-vivo imaging of human eyes, bulkmotion induced bulk phase must be identified and removed before using color Doppler method. It was found that the Doppler variance method is not sensitive to bulk motion and the method can be used without removing the bulk phase. A novel, simple and fast segmentation algorithm to indentify retinal pigment epithelium (RPE) was proposed and used to segment the retinal and choroidal layer. The algorithm was based on the detected OCT signal intensity difference between different layers. A spectrometer-based Fourier domain OCT system with a central wavelength of 890 nm and bandwidth of 150nm was used in this study. The 3-dimensional imaging volume contained 120 sequential two dimensional images with 2048 A-lines per image. The total imaging time was 12 seconds and the imaging area was 5x5 mm2.
The application of coded excitation technology in medical ultrasonic Doppler imaging
NASA Astrophysics Data System (ADS)
Li, Weifeng; Chen, Xiaodong; Bao, Jing; Yu, Daoyin
2008-03-01
Medical ultrasonic Doppler imaging is one of the most important domains of modern medical imaging technology. The application of coded excitation technology in medical ultrasonic Doppler imaging system has the potential of higher SNR and deeper penetration depth than conventional pulse-echo imaging system, it also improves the image quality, and enhances the sensitivity of feeble signal, furthermore, proper coded excitation is beneficial to received spectrum of Doppler signal. Firstly, this paper analyzes the application of coded excitation technology in medical ultrasonic Doppler imaging system abstractly, showing the advantage and bright future of coded excitation technology, then introduces the principle and the theory of coded excitation. Secondly, we compare some coded serials (including Chirp and fake Chirp signal, Barker codes, Golay's complementary serial, M-sequence, etc). Considering Mainlobe Width, Range Sidelobe Level, Signal-to-Noise Ratio and sensitivity of Doppler signal, we choose Barker codes as coded serial. At last, we design the coded excitation circuit. The result in B-mode imaging and Doppler flow measurement coincided with our expectation, which incarnated the advantage of application of coded excitation technology in Digital Medical Ultrasonic Doppler Endoscope Imaging System.
Pasha, Evan P; Tarumi, Takashi; Haley, Andreana P; Tanaka, Hirofumi
2017-11-30
We determined if transcranial color-coded Doppler derived hemodynamics are associated with MRI-based cerebral blood flow (CBF) in regions clinically important to dementia in healthy middle-aged adults. In 30 subjects (18m/12f; age = 52 ± 1 years), blood flow velocity (BFV) and cerebrovascular conductance (CVC) were measured with transcranial color-coded Doppler (TCCD) at the middle cerebral artery (MCA) and cerebral blood flow (CBF) was assessed with arterial spin labeled perfusion MRI. BFV and CVC were associated with hippocampus (r = 0.58 and r = 0.61, both p < 0.01) and occipitoparietal (r = 0.50 and r = 0.58, both p < 0.01) CBF. CVC was further associated with posterior cingulate CBF (r = 0.58 p < 0.01). Independent of age and sex, BFV and CVC were associated with hippocampus (r = 0.59 and r = 0.55, both p < 0.003) and occipitoparietal (r = 0.50 and r = 0.57, both p < 0.01) CBF. CVC was independently associated with posterior cingulate CBF (r = 0.38, p = 0.049). TCCD-measured BFV and CVC of the MCA are indicators of cerebral perfusion to clinically valuable brain regions in healthy middle-aged adults. TCCD may not be a good indicator of blood flow to cerebral white matter.
[Identification of cervical lymph node micrometastasis of tongue cancer by color Doppler and MRI].
Fan, Sufeng; Zhang, Quan; Li, Qiuli; Wang, Lina; Zheng, Lie; Liu, Longzhong
2014-01-01
To assess the values of color Doppler and magnetic resonance imaging (MRI) in the identification of cervical lymph node micrometastasis of tongue cancer. Totally 96 cases of tongue cancer with impalpable neck lymph node was examined with color Doppler and MRI within one week before surgery. Chi-square test was used to assess if the presence of regional lymph node micrometastasis, histopathological analysis as a golden standard lymph node micrometastasis. For the diagnosis of cervical lymph node micrometastasis, color Doppler was significantly better than MRI in sensitivity (72.5% vs 50.0%, P = 0.039) and the accuracy (78.1% vs 64.6%, P = 0.038), but no significant difference in the specificity (82.1% vs 75.0%, P = 0.357), the positive predictive value (74.4% vs 58.8%, P = 0.159) and the negative predictive value (80.7% vs 67.7%, P = 0.108). Color Doppler is better than MRI in the sensitivity and accuracy for the diagnosis of cervical lymph node micrometastasis of tongue cancer.
Herlta, Catherine; Starka, Rosa; Sigmarsson, Haukur L; Kauffold, Johannes
2018-06-01
To test for the feasibility of transabdominal Doppler sonography (color, power, pulse wave) to define uterine perfusion characteristics throughout the estrous cycle in gilts. A total of 15 gilts were synchronized for estrus and scanned in their following spontaneous cycle while being restrained in a purpose-designed mobile crate. To define uterine perfusion characteristics, vessels in between and within uterine cross-sections were imaged and recorded as video sequences to be analyzed by PixelFlux® software for perfused area (Amix), blood flow velocity (vmix) and intensity (Imix) as well as resistance (RIvmix) and pulsatility index (PIvmix). Color Doppler sonography proved to be the only feasible technique, as it was less affected by animal movements than power and pulse wave sonography. As determined by color Doppler sonography, all five parameters determined showed specific patterns through the estrous cycle, i. e. Amix, vmix, Imix were high in proestrus, decreased in estrus and remained low in midestrus and most parts of diestrus; RIvmix and PIvmix with inversely paralleled patterns. This study has demonstrated that transabdominal color Doppler but not power and pulse wave Doppler sonography is feasible to be performed in crate-restrained gilts for studying uterine perfusion characteristics during the estrous cycle, and that changes of uterine perfusion over the course of the estrous cycle can be clearly followed by color Doppler sonography. Results encourage the use of color Doppler sonography for studying i. e. uterine capacity or uterus related infertility such as for cases of clinically unapparent endometritis. Schattauer GmbH.
Yerli, Hasan; Eşki, Erkan
2015-01-01
This study aims to investigate the sonoelastography (SE), B-mode sonography, and color Doppler sonography findings of the pleomorphic adenomas and Warthin tumors of the parotid gland. A total of 84 parotid masses (23 pleomorphic adenomas, 25 Warthin tumors) in 72 patients (37 males, 35 females; mean age 59 years; range 30 to 79 years) were retrospectively analyzed. For each lesion, B-mode sonography, color Doppler sonography, and SE images were evaluated. Vascularity and elasticity scores of the tumors during color Doppler sonography and SE examinations were calculated by 4-scoring method. Lobulated contour and cystic areas were more common in the pleomorphic adenomas and Warthin tumors during the B-mode sonography examination (p<0.05). Peripheral vascularity was common in more than half of the pleomorphic adenoma patients, whereas central or mixed vascularity was seen in a large group of the Warthin tumor patients (p<0.05). The mean scores on color Doppler sonography examination were 1.13±0.81 for pleomorphic adenomas and 1.96±0.97 for Warthin tumors (p<0.05). The mean scores on SE examination were 2.69±0.70 for pleomorphic adenomas and 1.83±0.63 for Warthin tumors (p<0.05). Score 1 on SE examination was found in three of five Warthin tumor patients with peripheral vascularity on color Doppler sonography. B-mode, color Doppler and elastography examinations by sonography provide some helpful findings in the differentiation of pleomorphic adenomas and Warthin tumors.
A new fringeline-tracking approach for color Doppler ultrasound imaging phase unwrapping
NASA Astrophysics Data System (ADS)
Saad, Ashraf A.; Shapiro, Linda G.
2008-03-01
Color Doppler ultrasound imaging is a powerful non-invasive diagnostic tool for many clinical applications that involve examining the anatomy and hemodynamics of human blood vessels. These clinical applications include cardio-vascular diseases, obstetrics, and abdominal diseases. Since its commercial introduction in the early eighties, color Doppler ultrasound imaging has been used mainly as a qualitative tool with very little attempts to quantify its images. Many imaging artifacts hinder the quantification of the color Doppler images, the most important of which is the aliasing artifact that distorts the blood flow velocities measured by the color Doppler technique. In this work we will address the color Doppler aliasing problem and present a recovery methodology for the true flow velocities from the aliased ones. The problem is formulated as a 2D phase-unwrapping problem, which is a well-defined problem with solid theoretical foundations for other imaging domains, including synthetic aperture radar and magnetic resonance imaging. This paper documents the need for a phase unwrapping algorithm for use in color Doppler ultrasound image analysis. It describes a new phase-unwrapping algorithm that relies on the recently developed cutline detection approaches. The algorithm is novel in its use of heuristic information provided by the ultrasound imaging modality to guide the phase unwrapping process. Experiments have been performed on both in-vitro flow-phantom data and in-vivo human blood flow data. Both data types were acquired under a controlled acquisition protocol developed to minimize the distortion of the color Doppler data and hence to simplify the phase-unwrapping task. In addition to the qualitative assessment of the results, a quantitative assessment approach was developed to measure the success of the results. The results of our new algorithm have been compared on ultrasound data to those from other well-known algorithms, and it outperforms all of them.
Thermal effects of diagnostic ultrasound in an anthropomorphic skull model.
Vyskocil, E; Pfaffenberger, S; Kollmann, C; Gleiss, A; Nawratil, G; Kastl, S; Unger, E; Aumayr, K; Schuhfried, O; Huber, K; Wojta, J; Gottsauner-Wolf, M
2012-12-01
Exposure to diagnostic ultrasound (US) can significantly heat biological tissue although conventional routine examinations are regarded as safe. The risk of unwanted thermal effects increases with a high absorption coefficient and extended insonation time. Certain applications of transcranial diagnostic US (TC-US) require prolonged exposure. An anthropomorphic skull model (ASM) was developed to evaluate thermal effects induced by TC-US of different modalities. The objective was to determine whether prolonged continuous TC-US application results in potentially harmful temperature increases. The ASM consists of a human skull with tissue mimicking material and exhibits acoustic and anatomical characteristics of the human skull and brain. Experiments are performed with a diagnostic US device testing four different US modalities: Duplex PW (pulsed wave) Doppler, PW Doppler, color flow Doppler and B-mode. Temperature changes are recorded during 180 minutes of insonation. All measurements revealed significant temperature increases during insonation independent of the US modality. The maximum temperature elevation of + 5.25° C (p < 0.001) was observed on the surface of the skull exposed to duplex PW Doppler. At the bone-brain border a maximum temperature increae of + 2.01 °C (p < 0.001) was noted. Temperature increases within the brain were < 1.23 °C (p = 0.001). The highest values were registered using the duplex PW Doppler modality. TC-US induces significant local heating effects in an ASM. An application duration that extends routine clinical periods causes potentially harmful heating especially in tissue close to bone. TC-US elevates the temperature in the brain mimicking tissue but is not capable of producing harmful temperature increases during routine examinations. However, the risk of thermal injury in brain tissue increases significantly after an exposure time of > 2 hours. © Georg Thieme Verlag KG Stuttgart · New York.
Testa, Antonia Carla; Ferrandina, Gabriella; Fruscella, Erika; Van Holsbeke, Caroline; Ferrazzi, Enrico; Leone, Francesco P G; Arduini, Domenico; Exacoustos, Caterina; Bokor, Daniela; Scambia, Giovanni; Timmerman, Dirk
2005-09-01
The purpose of this study was to evaluate the efficacy of a new contrast-dedicated ultrasound technology, contrast-tuned imaging (CnTI), implemented on an endovaginal probe and using the second-generation contrast agent SonoVue (Bracco International BV, Amsterdam, the Netherlands), compared with the standard ultrasound examination in different gynecologic diseases. Eighty-nine patients were enrolled in the study in 4 different clinical centers. The study included 40 patients with uncertain pelvic adnexal masses, 10 patients with pelvic masses indicative of recurrences of gynecologic tumors, 26 patients with uterine pathologic features, and 13 patients with cervical lesions. Application of CnTI technology after the SonoVue injection gave a picture of the intralesional microvascularization dramatically different from that obtained during color Doppler examination. Of the 40 pelvic masses, 15 (37.5%) were considered benign and 25 (62.5%) were considered malignant at B-mode and color Doppler examinations. Contrast-enhanced sonography showed no intralesional contrast perfusion in 11 (73%) of 15 cases, and all these were benign at final diagnosis. Of the 4 (27%) cases that had perfusion, 2 were malignant. Conversely, of the 25 cases with positive findings at color Doppler examination and therefore expected to show the appearance of contrast tissue-filling morphologic characteristics, 13 (52%) were malignant at final diagnosis. For evaluation of uterine pathologic features, the CnTI-SonoVue technology did not appear to be superior to the B-mode and color Doppler examinations; however, for the evaluation of cervical cancer, CnTI-SonoVue technology revealed a better definition of the margins of the neoplastic lesions in 4 (40%) of 10 cases. In the evaluation of uncertain pelvic masses, the CnTI technology led to an improvement in the ability of the practitioner to differentiate benign from malignant adnexal lesions.
Gonçalves, Luís F; Romero, Roberto; Espinoza, Jimmy; Lee, Wesley; Treadwell, Marjorie; Chintala, Kavitha; Brandl, Helmut; Chaiworapongsa, Tinnakorn
2004-04-01
To describe clinical and research applications of 4-dimensional imaging of the fetal heart using color Doppler spatiotemporal image correlation. Forty-four volume data sets were acquired by color Doppler spatiotemporal image correlation. Seven subjects were examined: 4 fetuses without abnormalities, 1 fetus with ventriculomegaly and a hypoplastic cerebellum but normal cardiac anatomy, and 2 fetuses with cardiac anomalies detected by fetal echocardiography (1 case of a ventricular septal defect associated with trisomy 21 and 1 case of a double-inlet right ventricle with a 46,XX karyotype). The median gestational age at the time of examination was 21 3/7 weeks (range, 19 5/7-34 0/7 weeks). Volume data sets were reviewed offline by multiplanar display and volume-rendering methods. Representative images and online video clips illustrating the diagnostic potential of this technology are presented. Color Doppler spatiotemporal image correlation allowed multiplanar visualization of ventricular septal defects, multiplanar display and volume rendering of tricuspid regurgitation, volume rendering of the outflow tracts by color and power Doppler ultrasonography (both in a normal case and in a case of a double-inlet right ventricle with a double-outlet right ventricle), and visualization of venous streams at the level of the foramen ovale. Color Doppler spatiotemporal image correlation has the potential to simplify visualization of the outflow tracts and improve the evaluation of the location and extent of ventricular septal defects. Other applications include 3-dimensional evaluation of regurgitation jets and venous streams at the level of the foramen ovale.
SHEAR WAVE DISPERSION MEASURES LIVER STEATOSIS
Barry, Christopher T.; Mills, Bradley; Hah, Zaegyoo; Mooney, Robert A.; Ryan, Charlotte K.; Rubens, Deborah J.; Parker, Kevin J.
2012-01-01
Crawling waves, which are interfering shear wave patterns, can be generated in liver tissue over a range of frequencies. Some important biomechanical properties of the liver can be determined by imaging the crawling waves using Doppler techniques and analyzing the patterns. We report that the dispersion of shear wave velocity and attenuation, that is, the frequency dependence of these parameters, are strongly correlated with the degree of steatosis in a mouse liver model, ex vivo. The results demonstrate the possibility of assessing liver steatosis using noninvasive imaging methods that are compatible with color Doppler scanners and, furthermore, suggest that liver steatosis can be separated from fibrosis by assessing the dispersion or frequency dependence of shear wave propagations. PMID:22178165
Hausken, T; Li, X N; Goldman, B; Leotta, D; Ødegaard, S; Martin, R W
2001-07-01
To develop a non-invasive method for evaluating gastric emptying and duodenogastric reflux stroke volumes using three-dimensional (3D) guided digital color Doppler imaging. The technique involved color Doppler digital images of transpyloric flow in which the 3D position and orientation of the images were known by using a magnetic location system. In vitro, the system was found to slightly underestimate the reference flow (by average 8.8%). In vivo (five volunteers), stroke volume of gastric emptying episodes lasted on average only 0.69 s with a volume on average of 4.3 ml (range 1.1-7.4 ml), and duodenogastric reflux episodes on average 1.4 s with a volume of 8.3 ml (range 1.3-14.1 ml). With the appropriate instrument settings, orientation determined color Doppler can be used for stroke volume quantification of gastric emptying and duodenogastric reflux episodes.
NASA Technical Reports Server (NTRS)
Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.;
2001-01-01
Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.
Nemescu, Dragos; Berescu, Anca; Rotariu, Cristian
2015-12-01
The aim of our study was to analyze the variation of acoustic output, as expressed by the thermal (TI) and mechanical index (MI), during the learning curve for a fetal heart scan at 11-13 gestational weeks, with the introduction of a new ultrasound system. This was a prospective, observational study on 303 normal fetuses. The fetal heart was examined transabdominally using B-Mode and high definition (HD) color Doppler to obtain standard parameters: four-chamber, outflow tracts and three-vessel-trachea views. Data were analyzed in groups of 20 consecutive examinations and the percentage of successful examinations was calculated. TI and MI were retrieved from HD color Doppler examinations of the fetal heart and from pulsed-wave Doppler assessment of the tricuspid flow and ductus venosus. MI values from the color Doppler examination of the fetal heart showed a continuous decrease (0.81 to 0.75, p<0.001), along the learning phase. TI and MI indices from pulsed-wave Doppler evaluation of the tricuspid flow increased at the beginning of the learning phase and stabilized afterwards (0.34 to 0.36, p<0.05 and 0.37 to 0.4, p<0.001, respectively). TI from color Doppler exam of the heart and indices from ductus venosus assessment were very constant and did not change along the studied periods. The length of Doppler examination of the heart increased after about 80 cases by 25%, to a mean of 4 minutes (p<0.05). Safety indices from Doppler evaluation of the fetal heart and tricuspid flow vary during the learning curve for fetal heart assessment. Also, the occurrence of constant values suggests the potential for their supplementary active reduction. For a better adaptation to a new ultrasound technology, the sonographer should scan the fetal heart longer in the first trimester and follow displayed safety indices along the first 80 cases.
Automated assessment of noninvasive filling pressure using color Doppler M-mode echocardiography
NASA Technical Reports Server (NTRS)
Greenberg, N. L.; Firstenberg, M. S.; Cardon, L. A.; Zuckerman, J.; Levine, B. D.; Garcia, M. J.; Thomas, J. D.
2001-01-01
Assessment of left ventricular filling pressure usually requires invasive hemodynamic monitoring to follow the progression of disease or the response to therapy. Previous investigations have shown accurate estimation of wedge pressure using noninvasive Doppler information obtained from the ratio of the wave propagation slope from color M-mode (CMM) images and the peak early diastolic filling velocity from transmitral Doppler images. This study reports an automated algorithm that derives an estimate of wedge pressure based on the spatiotemporal velocity distribution available from digital CMM Doppler images of LV filling.
Zierler, R E; Phillips, D J; Beach, K W; Primozich, J F; Strandness, D E
1987-08-01
The combination of a B-mode imaging system and a single range-gate pulsed Doppler flow velocity detector (duplex scanner) has become the standard noninvasive method for assessing the extracranial carotid artery. However, a significant limitation of this approach is the small area of vessel lumen that can be evaluated at any one time. This report describes a new duplex instrument that displays blood flow as colors superimposed on a real-time B-mode image. Returning echoes from a linear array of transducers are continuously processed for amplitude and phase. Changes in phase are produced by tissue motion and are used to calculate Doppler shift frequency. This results in a color assignment: red and blue indicate direction of flow with respect to the ultrasound beam, and lighter shades represent higher velocities. The carotid bifurcations of 10 normal subjects were studied. Changes in flow velocities across the arterial lumen were clearly visualized as varying shades of red or blue during the cardiac cycle. A region of flow separation was observed in all proximal internal carotids as a blue area located along the outer wall of the bulb. Thus, it is possible to detect the localized flow patterns that characterize normal carotid arteries. Other advantages of color-flow imaging include the ability to rapidly identify the carotid bifurcation branches and any associated anatomic variations.
3D ultrafast ultrasound imaging in vivo.
Provost, Jean; Papadacci, Clement; Arango, Juan Esteban; Imbault, Marion; Fink, Mathias; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu
2014-10-07
Very high frame rate ultrasound imaging has recently allowed for the extension of the applications of echography to new fields of study such as the functional imaging of the brain, cardiac electrophysiology, and the quantitative imaging of the intrinsic mechanical properties of tumors, to name a few, non-invasively and in real time. In this study, we present the first implementation of Ultrafast Ultrasound Imaging in 3D based on the use of either diverging or plane waves emanating from a sparse virtual array located behind the probe. It achieves high contrast and resolution while maintaining imaging rates of thousands of volumes per second. A customized portable ultrasound system was developed to sample 1024 independent channels and to drive a 32 × 32 matrix-array probe. Its ability to track in 3D transient phenomena occurring in the millisecond range within a single ultrafast acquisition was demonstrated for 3D Shear-Wave Imaging, 3D Ultrafast Doppler Imaging, and, finally, 3D Ultrafast combined Tissue and Flow Doppler Imaging. The propagation of shear waves was tracked in a phantom and used to characterize its stiffness. 3D Ultrafast Doppler was used to obtain 3D maps of Pulsed Doppler, Color Doppler, and Power Doppler quantities in a single acquisition and revealed, at thousands of volumes per second, the complex 3D flow patterns occurring in the ventricles of the human heart during an entire cardiac cycle, as well as the 3D in vivo interaction of blood flow and wall motion during the pulse wave in the carotid at the bifurcation. This study demonstrates the potential of 3D Ultrafast Ultrasound Imaging for the 3D mapping of stiffness, tissue motion, and flow in humans in vivo and promises new clinical applications of ultrasound with reduced intra--and inter-observer variability.
Sun, Ruimei; Ding, Yu; Sun, Chuanzheng; Li, Xiaojiang; Wang, Jinde; Li, Lei; Yang, Jie; Ren, Yanxin; Zhong, Zhaoming
2016-04-01
To determine the importance of adequate preoperative assessment with color Doppler sonography to assist in the successful transfer of lateral upper arm flaps by studying the lateral upper arm flap with color Doppler sonography and analyzing the anatomic features of the radial collateral artery. A clinical case-control study was performed. The radial collateral artery was studied with color Doppler sonography in 15 healthy volunteers. The origins, courses, variations, and locations of the perforators of the radial collateral artery were recorded. The results and data from the color Doppler sonographic investigation were compared with an anatomic study that was performed on 22 adult cadaveric upper limb specimens. The volunteer group (14 of 15 volunteers) and the cadaveric group (19 of 22 upper arm specimens) clearly showed that the branch pattern of the arterial supply was as follows: brachial artery → deep brachial artery → radial collateral artery → posterior radial collateral artery → myocutaneous perforator. Variations in the origin of the radial collateral artery were identified in 1 volunteer bilaterally and in 3 upper arm specimens. The diameters of the artery and vein measured at the distal insertion of the deltoid and the origin of the deep brachial artery were not significantly different between the volunteer and cadaver groups (P > .05). Due to the difference in measuring methods, the length of the vascular pedicles was significantly different between the groups (P < .05). Color Doppler sonography can facilitate the preoperative assessment of the origin, course, variations, and locations of the radial collateral artery and therefore may increase the success rate of lateral upper arm flap transfer. © 2016 by the American Institute of Ultrasound in Medicine.
Dell'Atti, Lucio; Borea, Pier Andrea; Ughi, Gianni; Russo, Gian Rosario
2010-12-01
The purpose of this study is to evaluate the current role of the Ultrasound associated with the color-Doppler in the diagnosis of acute pyelonephritis (APN) and to compare ultrasound images with CT images in order to reduce the amount radiation absorbe without significant loss of diagnostic efficacy, since this disease in most cases affects young adults. We studied 38 patients (aged 17-65 years) who presented from September 2007 to March 2010 to the emergency department with suspected diagnosis of APN. All patients underwent first to an ultrasound study, then to abdominal CT. Renal, perirenal and extrarenal tomographic findings usually associated with acute pyelonephritis were analyzed, in an attempt to identify what are the differences with respect to the images obtained with an ultrasound study. All patients then performed ultrasonography and/or abdominal CT evaluation one month later, 25 patients repeated both examinations, while the other 13 repeated only ultrasound. In 38 subjects with suspected APN, CT assessed the presence in 79% and in 21% the absence of the disease. Ultrasonography in 68% of cases diagnosed APN, by an increase in kidney size related to the presence of hypoechoic areas associated to edema, blurred margins and reduction of the color-Doppler vascularity. Ultrasound associated with the use of color-Doppler revealed a sensibility of 76% and specificity of 75%. Color and power-Doppler have better diagnostic accuracy than basic gray scale ultrasound, in the diagnosis of focal pyelonephritis. Therefore the combined use of ultrasound and color-Doppler can obtain useful information about the diagnosis and follow-up of the disease, with an improvement in terms of cost, without significantly altering the diagnostic efficacy and reducing the amount of radiation absorbed.
Amphetamine-associated ischemic stroke: clinical presentation and proposed pathogenesis.
De Silva, Deidre Anne; Wong, Meng Cheong; Lee, Moi Pin; Chen, Christopher Li-Hsian; Chang, Hui Meng
2007-01-01
We report a young lady with acute left middle cerebral artery infarction after acute intake of amphetamine. This is the first case report of amphetamine-induced ischemic stroke with serial angiography and transcranial color-coded Doppler studies. The temporal sequence of stenosis of at least 3 weeks with subsequent complete resolution by 3 months and a "beaded" appearance on angiography support vasculitis or vasospasm as the pathogenesis of ischemic stroke in this patient. The presence of microembolic signals supports acute thrombosis at the site of vasculitis/vasospasm with distal embolism.
Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares
2018-02-01
We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p < 0.0005). Aortic flow showed no difference between ECG- and Doppler-triggered and MOG (p > 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.
Fisher, E A; Estioko, M R; Stern, E H; Goldman, M E
1987-07-01
Aortic root abscess occurs frequently in aortic prosthetic valve infective endocarditis. The present echocardiographic report documents a ruptured abscess that led to a direct communication between the left ventricular outflow tract and the left atrium confirmed by real-time (color flow) Doppler imaging.
Destructive effect of HIFU on rabbit embedded endometrial carcinoma tissues and their vascularities
Guan, Liming; Xu, Gang
2017-01-01
Objectives To evaluate damage effect of High-intensity focused ultrasound on early stage endometrial cancer tissues and their vascularities. Materials and Methods Rabbit endometrial cancer models were established via tumor blocks implantation for a prospective control study. Ultrasonic ablation efficacy was evaluated by pathologic and imaging changes. The target lesions of experimental rabbits before and after ultrasonic ablation were observed after autopsy. The slides were used for hematoxylin-eosin staining, elastic fiber staining and endothelial cell staining; the slides were observed by optical microscopy. One slide was observed by electron microscopy. Then the target lesions of experimental animals with ultrasonic ablation were observed by vascular imaging, one group was visualized by digital subtract angiography, one group was quantified by color Doppler flow imaging, and one group was detected by dye perfusion. SPSS 19.0 software was used for statistical analyses. Results Histological examination indicated that High-intensity focused ultrasound caused the tumor tissues and their vascularities coagulative necrosis. Tumor vascular structure components including elastic fiber, endothelial cells all were destroyed by ultrasonic ablation. Digital subtract angiography showed tumor vascular shadow were dismissed after ultrasonic ablation. After ultrasonic ablation, gray-scale of tumor nodules enhanced in ultrasonography, tumor peripheral and internal blood flow signals disappeared or significantly reduced in color Doppler flow imaging. Vascular perfusion performed after ultrasonic ablation, tumor vessels could not filled by dye liquid. Conclusion High-intensity focused ultrasound as a noninvasive method can destroy whole endometrial cancer cells and their supplying vascularities, which maybe an alternative approach of targeted therapy and new antiangiogenic strategy for endometrial cancer. PMID:28121624
Destructive effect of HIFU on rabbit embedded endometrial carcinoma tissues and their vascularities.
Guan, Liming; Xu, Gang
2017-03-21
To evaluate damage effect of High-intensity focused ultrasound on early stage endometrial cancer tissues and their vascularities. Rabbit endometrial cancer models were established via tumor blocks implantation for a prospective control study. Ultrasonic ablation efficacy was evaluated by pathologic and imaging changes. The target lesions of experimental rabbits before and after ultrasonic ablation were observed after autopsy. The slides were used for hematoxylin-eosin staining, elastic fiber staining and endothelial cell staining; the slides were observed by optical microscopy. One slide was observed by electron microscopy. Then the target lesions of experimental animals with ultrasonic ablation were observed by vascular imaging, one group was visualized by digital subtract angiography, one group was quantified by color Doppler flow imaging, and one group was detected by dye perfusion.SPSS 19.0 software was used for statistical analyses. Histological examination indicated that High-intensity focused ultrasound caused the tumor tissues and their vascularities coagulative necrosis. Tumor vascular structure components including elastic fiber, endothelial cells all were destroyed by ultrasonic ablation. Digital subtract angiography showed tumor vascular shadow were dismissed after ultrasonic ablation. After ultrasonic ablation, gray-scale of tumor nodules enhanced in ultrasonography, tumor peripheral and internal blood flow signals disappeared or significantly reduced in color Doppler flow imaging. Vascular perfusion performed after ultrasonic ablation, tumor vessels could not filled by dye liquid. High-intensity focused ultrasound as a noninvasive method can destroy whole endometrial cancer cells and their supplying vascularities, which maybe an alternative approach of targeted therapy and new antiangiogenic strategy for endometrial cancer.
Usefulness of color Doppler sonography in a growing skull fracture: case report.
Yoshioka, H; Sakoda, K; Kohno, H; Hada, H; Kurisu, K
1997-01-01
A case of an 11-month-old infant with a growing skull fracture is described. The patient was admitted with disturbance of consciousness and left hemiparesis after a severe head injury. A pulsating protrusion appeared over the fracture line 1 month later. Color Doppler sonography revealed cerebral herniation and cystic lesion via the bony defect, together with an intracranial arterial flow pattern detected in the extracranial space. Color Doppler sonography was very useful in the diagnosis of growing skull fracture and in the evaluation of the intracranial state, including hemodynamics in this case. Successful surgical treatment was performed on the basis of sonographic data and the patient was discharged 3 months later without motor deficits.
Intrahepatic portosystemic venous shunt: diagnosis by color Doppler imaging.
Kudo, M; Tomita, S; Tochio, H; Minowa, K; Todo, A
1993-05-01
Intrahepatic portosystemic venous shunt is a rare clinical entity; only 33 such cases have been reported. It may be congenital, or secondary to portal hypertension. Five patients with this disorder are presented, each of whom was diagnosed by color Doppler imaging, including waveform spectral analysis. One patient with clinical evidence of cirrhosis and portal hypertension had episodes of hepatic encephalopathy and elevated blood levels of ammonia. This patient had a large tubular shunt between the posterior branch of the portal vein and the inferior vena cava. Shunts of this type are considered to be collateral pathways which develop in the hepatic parenchyma as a result of portal hypertension. The other four patients had no evidence of liver disease, and all four evidenced an aneurysmal portohepatic venous shunt within the liver parenchyma. Shunts of this type are considered congenital. The diagnosis of intrahepatic portosystemic venous shunts was established by color Doppler imaging, which demonstrated a direct communication of color flow signals between the portal vein and hepatic vein, in addition to the characterization of the Doppler spectrum at each sampling point from a continuous waveform signal (portal vein) to a turbulent signal (aneurysmal cavity), and finally, to a biphasic waveform signal (hepatic vein). As demonstrated by the five patients, color Doppler imaging is useful in the diagnosis of an intrahepatic portosystemic hepatic venous shunt, and the measurement of shunt ratio may be useful in the follow-up and determining the therapeutic option.
Three-dimensional color Doppler imaging of the carotid artery
NASA Astrophysics Data System (ADS)
Picot, Paul A.; Rickey, Daniel W.; Mitchell, Ross; Rankin, Richard N.; Fenster, Aaron
1991-05-01
Stroke is the third leading cause of death in the United States. It is caused by ischemic injury to the brain, usually resulting from emboli from atherosclerotic plaques. The carotid bifurcation in humans is prone to atherosclerotic disease and is a site where emboli may originate. Currently, carotid stenoses are evaluated by non-invasive duplex Doppler ultrasound, with preoperative verification by intra-arterial angiography. We have developed a system that uses a color Doppler ultrasound imaging system to acquire in-vivo 3-D color Doppler images of the human carotid artery, with the aim of increasing the diagnostic accuracy of ultrasound and decreasing the use of angiography for verification. A clinical TL Ultramark 9 color Doppler ultrasound system was modified by mounting the hand-held ultrasound scan head on a motor-driven translation stage. The stage allows planar ultrasound images to be acquired over 45 mm along the neck between the clavicle and the mandible. A 3- D image is acquired by digitizing, in synchrony with the cardiac cycle, successive color ultrasound video images as the scan head is stepped along the neck. A complete volume set of 64 frames, comprising some 15 megabytes of data, requires approximately 2 minutes to acquire. The volume image is reformatted and displayed on a Sun 4/360 workstation equipped with a TAAC-1 graphics accelerator. The 3-D image may be manipulated in real time to yield the best view of blood flow in the bifurcation.
Ozdemir, Rahmi; Kucuk, Mehmet; Guzel, Orkide; Karadeniz, Cem; Yilmaz, Unsal; Mese, Timur
2016-10-01
The ketogenic diet (KD) has been referred to as an "effective therapy with side effects" for children with intractable epilepsy. Among the most recognized adverse effects, there are cardiac conduction abnormalities, vascular and myocardial dysfunction. However, very limited and controversial data are available regarding the effects of the KD on cardiac functions. We sought to analyze the mid-term effect of ketogenic diet on cardiac functions in patients with intractable epilepsy who received a ketogenic diet for at least 12months using conventional and relatively new imaging techniques. This prospective study included 61 patients with intractable epilepsy who received ketogenic diet for at least 12months. Clinical examinations, serum carnitine and selenium levels as well as electrocardiographic and echocardiographic examinations were scheduled prior to the procedure and at 1, 3, 6 and 12months. We utilized two-dimensional, M-mode, colored Doppler, spectral Doppler and pulsed wave tissue Doppler imaging techniques to investigate ventricular systolic and diastolic functions of this subgroup of patients. In our study, there was no significant difference after 1year of KD therapy compared to baseline values-except a significantly decreased A wave velocity-in terms of pulse wave Doppler echocardiographic measurements of the diastolic function. The tissue Doppler measurements obtained from the lateral wall of tricuspide and mitral annuli were not different at baseline and at month 12 of the treatment, as well. The ketogenic diet appears to have no disturbing effect on ventricular functions in epileptic children in the midterm. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Nikitin, N P; Loh, P H; de Silva, R; Ghosh, J; Khaleva, O Y; Goode, K; Rigby, A S; Alamgir, F; Clark, A L; Cleland, J G F
2006-01-01
Objective To assess the prognostic value of various conventional and novel echocardiographic indices in patients with chronic heart failure (CHF) caused by left ventricular (LV) systolic dysfunction. Methods 185 patients with a mean (SD) age of 67 (11) years with CHF and LV ejection fraction < 45% despite optimal pharmacological treatment were prospectively enrolled. The patients underwent two dimensional echocardiography with tissue harmonic imaging to assess global LV systolic function and obtain volumetric data. Transmitral flow was assessed with conventional pulse wave Doppler. Systolic (Sm), early, and late diastolic mitral annular velocities were measured with the use of colour coded Doppler tissue imaging. Results During a median follow up of 32 months (range 24–38 months in survivors), 34 patients died and one underwent heart transplantation. Sm velocity (hazard ratio (HR) 0.648, 95% confidence interval (CI) 0.463 to 0.907, p = 0.011), diastolic arterial pressure (HR 0.965, 95% CI 0.938 to 0.993, p = 0.015), serum creatinine (HR 1.006, 95% CI 1.001 to 1.011, p = 0.023), LV ejection fraction (HR 0.945, 95% CI 0.899 to 0.992, p = 0.024), age (HR 1.035, 95% CI 1.000 to 1.071, p = 0.052), LV end systolic volume index (HR 1.009, 95% CI 0.999 to 1.019, p = 0.067), and restrictive pattern of transmitral flow (HR 0.543, 95% CI 0.278 to 1.061, p = 0.074) predicted the outcome of death or transplantation on univariate analysis. On multivariate analysis, only Sm velocity (HR 0.648, 95% CI 0.460 to 0.912, p = 0.013) and diastolic arterial pressure (HR 0.966, 95% CI 0.938 to 0.994, p = 0.016) emerged as independent predictors of outcome. Conclusions In patients with CHF and LV systolic dysfunction despite optimal pharmacological treatment, the strongest independent echocardiographic predictor of prognosis was Sm velocity measured with quantitative colour coded Doppler tissue imaging. PMID:16251233
Wang, Yu; Duan, Yun-You; Zhou, Hai-Yan; Yuan, Li-Jun; Zhang, Li; Wang, Wei; Li, Li-Hong; Li, Liang
2014-12-01
Intracranial pressure usually increases after severe brain injury. However, a method for noninvasive evaluation of intracranial pressure is still lacking. The purpose of this study was to explore the potential role of transcranial color Doppler sonography in assessing intracranial pressure by observing the middle cerebral artery blood flow parameters in patients with increased intracranial pressure of varying etiology. The hemodynamic changes in the middle cerebral artery in patients with varying degrees of increased intracranial pressure were investigated by transcranial color Doppler sonography in 93 patients who had emergency surgery for brain injury. Middle cerebral artery Doppler flow spectra changed regularly as intracranial pressure increased. The pulsatility index (PI) and resistive index (RI) had a significantly positive correlation with intracranial pressure (r = 0.90 and 0.89, respectively; P< .001), whereas the middle cerebral artery diastolic velocity showed a significant negative correlation with intracranial pressure (r = -0.52; P< .01). A receiver operating characteristic curve showed that the RI and PI cutoff values were 0.705 and 1.335, respectively, for predicting increased intracranial pressure, with sensitivity of 0.885 and specificity of 0.970. In addition to the PI and RI, middle cerebral artery diastolic flow velocity measurement by transcranial color Doppler sonography may also be a useful variable for evaluating intracranial pressure in patients with acute brain injury. © 2013 by the American Institute of Ultrasound in Medicine.
Chetboul, Valerie; Sampedrano, Carolina Carlos; Gouni, Vassiliki; Nicolle, Audrey P; Pouchelon, Jean-Louis
2006-01-01
A 20-month-old healthy male Maine Coon cat was referred for a cardiovascular evaluation. Physical examination and electrocardiogram were normal. The end-diastolic subaortic interventricular septal thickness (6 mm; reference range: < or = 6mm) and the mitral flow late diastolic velocity (0.89 m/s; reference range: 0.2-0.8m/s) were within the upper ranges. However, M-mode echocardiography did not reveal any sign of hypertrophic cardiomyopathy (HCM). Tissue Doppler imaging (TDI) identified a marked left ventricular free wall dysfunction characterized by decreased myocardial velocities in early diastole, increased myocardial velocities in late diastole and the presence of postsystolic contractions both at the base and the apex for the longitudinal motion. One year later, the diagnosis of HCM was confirmed by conventional echocardiography and the cat died suddenly 2 months later. This report demonstrates for the first time in spontaneous HCM the sensitivity of TDI for early diagnosis of myocardial dysfunction and suggests that TDI should form part of the screening techniques for early diagnosis of feline HCM.
The Short-Term Effects of Ketogenic Diet on Cardiac Ventricular Functions in Epileptic Children.
Doksöz, Önder; Çeleğen, Kübra; Güzel, Orkide; Yılmaz, Ünsal; Uysal, Utku; İşgüder, Rana; Çeleğen, Mehmet; Meşe, Timur
2015-09-01
Our primary aim was to determine the short-term effects of a ketogenic diet on cardiac ventricular function in patients with refractory epilepsy. Thirty-eight drug-resistant epileptic patients who were treated with a ketogenic diet were enrolled in this prospective study. Echocardiography was performed on all patients before beginning the ketogenic diet and after the sixth month of therapy. Two-dimensional, M-mode, color flow, spectral Doppler, and pulsed-wave tissue Doppler imaging measurements were performed on all patients. The median age of the 32 patients was 45.5 months, and 22 (57.8%) of them were male. Body weight, height, and body mass index increased significantly at the sixth month of therapy when compared with baseline values (P < 0.05). Baseline variables assessed by conventional M-mode echocardiography showed no significant difference at month 6 (P > 0.05). Doppler flow indices of mitral annulus and tricuspid annulus velocity of patients at baseline and month 6 showed no significant differences (P > 0.05). Tricuspid annular E/A ratio was lower at month 6 (P < 0.05). Although mitral annulus tissue Doppler imaging studies showed no significant difference (P > 0.05), there was a decrease in Ea velocity and Ea/Aa ratio gathered from tricuspid annulus at month 6 compared with baseline (P < 0.05). A 6-month duration ketogenic diet does not impair left ventricular functions in children with refractory epilepsy; however, it may be associated with a right ventricular diastolic dysfunction. Copyright © 2015 Elsevier Inc. All rights reserved.
Quantitative characterization of color Doppler images: reproducibility, accuracy, and limitations.
Delorme, S; Weisser, G; Zuna, I; Fein, M; Lorenz, A; van Kaick, G
1995-01-01
A computer-based quantitative analysis for color Doppler images of complex vascular formations is presented. The red-green-blue-signal from an Acuson XP10 is frame-grabbed and digitized. By matching each image pixel with the color bar, color pixels are identified and assigned to the corresponding flow velocity (color value). Data analysis consists of delineation of a region of interest and calculation of the relative number of color pixels in this region (color pixel density) as well as the mean color value. The mean color value was compared to flow velocities in a flow phantom. The thyroid and carotid artery in a volunteer were repeatedly examined by a single examiner to assess intra-observer variability. The thyroids in five healthy controls were examined by three experienced physicians to assess the extent of inter-observer variability and observer bias. The correlation between the mean color value and flow velocity ranged from 0.94 to 0.96 for a range of velocities determined by pulse repetition frequency. The average deviation of the mean color value from the flow velocity was 22% to 41%, depending on the selected pulse repetition frequency (range of deviations, -46% to +66%). Flow velocity was underestimated with inadequately low pulse repetition frequency, or inadequately high reject threshold. An overestimation occurred with inadequately high pulse repetition frequency. The highest intra-observer variability was 22% (relative standard deviation) for the color pixel density, and 9.1% for the mean color value. The inter-observer variation was approximately 30% for the color pixel density, and 20% for the mean color value. In conclusion, computer assisted image analysis permits an objective description of color Doppler images. However, the user must be aware that image acquisition under in vivo conditions as well as physical and instrumental factors may considerably influence the results.
Sonographic features of neonatal mastitis and breast abscess.
Borders, Heather; Mychaliska, George; Gebarski, K Stiennon
2009-09-01
Neonatal mastitis and neonatal breast abscess are uncommon. Although well described in the pediatric and surgical literature, there is a paucity of reports describing their sonographic features. To describe and illustrate the sonographic features of neonatal mastitis and neonatal breast abscess. We reviewed the medical database of a large children's health-care center from 2000 through 2008 for patients presenting in the first 8 weeks of life with mastitis. The findings were correlated with clinical presentation and course, laboratory findings and clinical outcome. Four neonates (three girls and one boy) presented with mastitis. They all had prominent breast buds on the affected side with poorly defined margins, slightly more echogenic focally or diffusely compared to normal with hyperemia on color flow Doppler US. The surrounding subcutaneous tissue was thick and echogenic. Two abscesses presented as avascular areas without color flow on Doppler US, subtly increased through-transmission and surrounding hyperemia. One abscess was of increased echogenicity while the other was anechoic. Neonatal mastitis and breast abscess are unusual diseases that should be appropriately treated with antibiotics and drainage to avoid generalized sepsis, breast hypoplasia, and scarring. US is useful in distinguishing mastitis from breast abscess and guiding treatment options.
Right Ventricular Tissue Doppler in Space Flight
NASA Technical Reports Server (NTRS)
Garcia, Kathleen M.; Hamilton, Douglas R.; Sargsyan, Ashot E.; Ebert, Douglas; Martin, David S.; Barratt, Michael R.; Martin, David S.; Bogomolov, Valery V.; Dulchavsky, Scott A.; Duncan, J. Michael
2010-01-01
The presentation slides review normal physiology of the right ventricle in space, general physiology of the right ventricle; difficulties in imaging the heart in space, imaging methods, tissue Doppler spectrum, right ventricle tissue Doppler, and Rt Tei Index.
Pretolesi, F; Silvestri, E; Di Maio, G; Martinoli, C; Onetto, F; Sala, P; Derchi, L E
1997-01-01
The aim of this study was to evaluate the changes in volume, structure, and flow pattern of parathyroid glands in uremic patients with secondary hyperparathyroidism treated with long-term intravenous calcitriol (CTL) therapy. Ultrasonography was used to follow-up volume changes occurring in 18 enlarged glands in 11 patients during an 18-month period; in 6 of these cases, 11 glands were followed-up also with color-Doppler to monitor variations in flow pattern. Vascularization was classified using three grades: grade 0 = no color signal; grade I = vessels covering less than 50 % of glandular cross-sectional area; grade II = vascular signals covering more than 50 % of glandular cross-sectional area. No significant changes in volume were demonstrated during the 18 months of follow-up. On the contrary, significant decrease in flow was observed with almost complete disappearance of color-Doppler signals. This finding related well with the observed decrease in parathormone blood levels. Lack of volume changes during medical therapy demonstrates the inability of US alone to monitor the effect of this treatment on the parathyroid glands. Conversely, the observed intraglandular flow reduction indicates the possibility to use color Doppler to monitor the effects of CLT in uremic hemodialyzed patients with secondary hyperparathyroidism. This imaging procedure can be proposed for follow-up of the response of the parathyroid glands to therapy.
Little, Stephen H; Pirat, Bahar; Kumar, Rahul; Igo, Stephen R; McCulloch, Marti; Hartley, Craig J; Xu, Jiaqiong; Zoghbi, William A
2008-11-01
Our goal was to prospectively compare the accuracy of real-time three-dimensional (3D) color Doppler vena contracta (VC) area and two-dimensional (2D) VC diameter in an in vitro model and in the clinical assessment of mitral regurgitation (MR) severity. Real-time 3D color Doppler allows direct measurement of VC area and may be more accurate for assessment of MR than the conventional VC diameter measurement by 2D color Doppler. Using a circulatory loop with an incorporated imaging chamber, various pulsatile flow rates of MR were driven through 4 differently sized orifices. In a clinical study of patients with at least mild MR, regurgitation severity was assessed quantitatively using Doppler-derived effective regurgitant orifice area (EROA), and semiquantitatively as recommended by the American Society of Echocardiography. We describe a step-by-step process to accurately identify the 3D-VC area and compare that measure against known orifice areas (in vitro study) and EROA (clinical study). In vitro, 3D-VC area demonstrated the strongest correlation with known orifice area (r = 0.92, p < 0.001), whereas 2D-VC diameter had a weak correlation with orifice area (r = 0.56, p = 0.01). In a clinical study of 61 patients, 3D-VC area correlated with Doppler-derived EROA (r = 0.85, p < 0.001); the relation was stronger than for 2D-VC diameter (r = 0.67, p < 0.001). The advantage of 3D-VC area over 2D-VC diameter was more pronounced in eccentric jets (r = 0.87, p < 0.001 vs. r = 0.6, p < 0.001, respectively) and in moderate-to-severe or severe MR (r = 0.80, p < 0.001 vs. r = 0.18, p = 0.4, respectively). Measurement of VC area is feasible with real-time 3D color Doppler and provides a simple parameter that accurately reflects MR severity, particularly in eccentric and clinically significant MR where geometric assumptions may be challenging.
Little, Stephen H.; Pirat, Bahar; Kumar, Rahul; Igo, Stephen R.; McCulloch, Marti; Hartley, Craig J.; Xu, Jiaqiong; Zoghbi, William A.
2012-01-01
OBJECTIVES Our goal was to prospectively compare the accuracy of real-time three-dimensional (3D) color Doppler vena contracta (VC) area and two-dimensional (2D) VC diameter in an in vitro model and in the clinical assessment of mitral regurgitation (MR) severity. BACKGROUND Real-time 3D color Doppler allows direct measurement of VC area and may be more accurate for assessment of MR than the conventional VC diameter measurement by 2D color Doppler. METHODS Using a circulatory loop with an incorporated imaging chamber, various pulsatile flow rates of MR were driven through 4 differently sized orifices. In a clinical study of patients with at least mild MR, regurgitation severity was assessed quantitatively using Doppler-derived effective regurgitant orifice area (EROA), and semiquantitatively as recommended by the American Society of Echocardiography. We describe a step-by-step process to accurately identify the 3D-VC area and compare that measure against known orifice areas (in vitro study) and EROA (clinical study). RESULTS In vitro, 3D-VC area demonstrated the strongest correlation with known orifice area (r = 0.92, p < 0.001), whereas 2D-VC diameter had a weak correlation with orifice area (r = 0.56, p = 0.01). In a clinical study of 61 patients, 3D-VC area correlated with Doppler-derived EROA (r = 0.85, p < 0.001); the relation was stronger than for 2D-VC diameter (r = 0.67, p < 0.001). The advantage of 3D-VC area over 2D-VC diameter was more pronounced in eccentric jets (r = 0.87, p < 0.001 vs. r = 0.6, p < 0.001, respectively) and in moderate-to-severe or severe MR (r = 0.80, p < 0.001 vs. r = 0.18, p = 0.4, respectively). CONCLUSIONS Measurement of VC area is feasible with real-time 3D color Doppler and provides a simple parameter that accurately reflects MR severity, particularly in eccentric and clinically significant MR where geometric assumptions may be challenging. PMID:19356505
Garcia, M J; Smedira, N G; Greenberg, N L; Main, M; Firstenberg, M S; Odabashian, J; Thomas, J D
2000-01-01
To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.
Preoperative color Doppler assessment in planning of gluteal perforator flaps.
Isken, Tonguc; Alagoz, M Sahin; Onyedi, Murat; Izmirli, Hakki; Isil, Eda; Yurtseven, Nagehan
2009-02-01
Gluteal artery perforator flaps have gained popularity due to reliability, preservation of the muscle, versatility in flap design without restricting other flap options, and low donor-site morbidity in ambulatory patients and possibility of enabling future reconstruction in paraplegic patients. But the inconstant anatomy of the vascular plexus around the gluteal muscle makes it hard to predict how many perforators are present, what their volume of blood flow and size are, where they exit the overlying fascia, and what their course through the muscle will be. Without any prior investigations, the reconstructive surgeon could be surprised intraoperatively by previous surgical damage, scar formation, or anatomic variants.For these reasons, to confirm the presence and the location of gluteal perforators preoperatively we have used color Doppler ultrasonography. With the help of the color Doppler ultrasonography 26 patients, 21 men and 5 women, were operated between the years 2002 and 2007. The mean age of patients was 47.7 (age range: 7-77 years). All perforator vessels were marked preoperatively around the defect locations. The perforator based flap that will allow primary closure of the donor site and the defect without tension was planned choosing the perforator that showed the largest flow in color Doppler ultrasonography proximally. Perforators were found in the sites identified with color Doppler ultrasonography in all other flaps. In our study, 94.4% flap viability was ensured in 36 perforator-based gluteal area flaps. Mean flap elevation time was 31.9 minutes. We found that locating the perforators preoperatively helps to shorten the operation time without compromising a reliable viability of the perforator flaps, thus enabling the surgeon easier treatment of pressure sores.
NASA Technical Reports Server (NTRS)
Garcia, M. J.; Smedira, N. G.; Greenberg, N. L.; Main, M.; Firstenberg, M. S.; Odabashian, J.; Thomas, J. D.
2000-01-01
OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.
Pirat, Bahar; Little, Stephen H; Igo, Stephen R; McCulloch, Marti; Nosé, Yukihiko; Hartley, Craig J; Zoghbi, William A
2009-03-01
The proximal isovelocity surface area (PISA) method is useful in the quantitation of aortic regurgitation (AR). We hypothesized that actual measurement of PISA provided with real-time 3-dimensional (3D) color Doppler yields more accurate regurgitant volumes than those estimated by 2-dimensional (2D) color Doppler PISA. We developed a pulsatile flow model for AR with an imaging chamber in which interchangeable regurgitant orifices with defined shapes and areas were incorporated. An ultrasonic flow meter was used to calculate the reference regurgitant volumes. A total of 29 different flow conditions for 5 orifices with different shapes were tested at a rate of 72 beats/min. 2D PISA was calculated as 2pi r(2), and 3D PISA was measured from 8 equidistant radial planes of the 3D PISA. Regurgitant volume was derived as PISA x aliasing velocity x time velocity integral of AR/peak AR velocity. Regurgitant volumes by flow meter ranged between 12.6 and 30.6 mL/beat (mean 21.4 +/- 5.5 mL/beat). Regurgitant volumes estimated by 2D PISA correlated well with volumes measured by flow meter (r = 0.69); however, a significant underestimation was observed (y = 0.5x + 0.6). Correlation with flow meter volumes was stronger for 3D PISA-derived regurgitant volumes (r = 0.83); significantly less underestimation of regurgitant volumes was seen, with a regression line close to identity (y = 0.9x + 3.9). Direct measurement of PISA is feasible, without geometric assumptions, using real-time 3D color Doppler. Calculation of aortic regurgitant volumes with 3D color Doppler using this methodology is more accurate than conventional 2D method with hemispheric PISA assumption.
Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao
2014-03-01
Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.
A feasability study of color flow doppler vectorization for automated blood flow monitoring.
Schorer, R; Badoual, A; Bastide, B; Vandebrouck, A; Licker, M; Sage, D
2017-12-01
An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with a focus on simplicity and monitoring instead of diagnostics. We then analyze the performance of a proof-of-principle software implementation. We imagined a geometrical model geared towards blood flow computation from a color flow Doppler signal, and we developed a software implementation requiring only a standard diagnostic ultrasound device. Detection performance was evaluated by computing flow and its determinants (flow speed, vessel area, and ultrasound beam angle of incidence) on purposely designed synthetic and phantom-based arterial flow simulations. Flow was appropriately detected in all cases. Errors on synthetic images ranged from nonexistent to substantial depending on experimental conditions. Mean errors on measurements from our phantom flow simulation ranged from 1.2 to 40.2% for angle estimation, and from 3.2 to 25.3% for real-time flow estimation. This study is a proof of concept showing that accurate measurement can be done from automated color flow Doppler signal extraction, providing the industry the opportunity for further optimization using raw ultrasound data.
Power Doppler of the urethra in continent or incontinent, pre- and postmenopausal women.
Jármy-Di Bella, Z I; Girão, M J; Sartori, M F; Di Bella Júnior, V; Lederman, H M; Baracat, E C; Lima, G R
2000-06-01
Urethral pressure should exceed bladder pressure, both at rest and on stress, for urinary continence to occur. A decrease in urethral pressure is a major factor explaining the pathogenesis of urinary incontinence. A number of elements, such as smooth and striated periurethral muscles, and connective, vascular and elastic tissues, contribute to urethral pressure. The periurethral vessels are influenced by hormonal changes during the menstrual cycle, during pregnancy and postmenopause. We studied the periurethral vessels in 97 women, 57 of whom were incontinent and 40 continent, using power color Doppler velocimetry. The number of periurethral vessels, systolic peak, minimum diastolic values, pulsatility and resistance indexes, as well as systolic-diastolic ratio, were assessed. Statistically significant differences were found between incontinent women in the premenopausal period and those in the postmenopausal period, regarding the number of periurethral vessels, systolic peak, minimum diastolic values, pulsatility and resistance indexes.
Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A
2006-01-01
To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85%) of HCC cases. All 19 hemangiomas were correctly classified by phase inversion imaging. Contrast medium-enhanced ultrasound investigation of liver tumors with Optison allowed reliable detection of tumor foci and, in most cases, appraisal of tumor vascularization. The time available for evaluation of tumor margin vascularization was substantially longer in B-flow.
Blind ICA detection based on second-order cone programming for MC-CDMA systems
NASA Astrophysics Data System (ADS)
Jen, Chih-Wei; Jou, Shyh-Jye
2014-12-01
The multicarrier code division multiple access (MC-CDMA) technique has received considerable interest for its potential application to future wireless communication systems due to its high data rate. A common problem regarding the blind multiuser detectors used in MC-CDMA systems is that they are extremely sensitive to the complex channel environment. Besides, the perturbation of colored noise may negatively affect the performance of the system. In this paper, a new coherent detection method will be proposed, which utilizes the modified fast independent component analysis (FastICA) algorithm, based on approximate negentropy maximization that is subject to the second-order cone programming (SOCP) constraint. The aim of the proposed coherent detection is to provide robustness against small-to-medium channel estimation mismatch (CEM) that may arise from channel frequency response estimation error in the MC-CDMA system, which is modulated by downlink binary phase-shift keying (BPSK) under colored noise. Noncoherent demodulation schemes are preferable to coherent demodulation schemes, as the latter are difficult to implement over time-varying fading channels. Differential phase-shift keying (DPSK) is therefore the natural choice for an alternative modulation scheme. Furthermore, the new blind differential SOCP-based ICA (SOCP-ICA) detection without channel estimation and compensation will be proposed to combat Doppler spread caused by time-varying fading channels in the DPSK-modulated MC-CDMA system under colored noise. In this paper, numerical simulations are used to illustrate the robustness of the proposed blind coherent SOCP-ICA detector against small-to-medium CEM and to emphasize the advantage of the blind differential SOCP-ICA detector in overcoming Doppler spread.
B-mode Ultrasound Versus Color Doppler Twinkling Artifact in Detecting Kidney Stones
Harper, Jonathan D.; Hsi, Ryan S.; Shah, Anup R.; Dighe, Manjiri K.; Carter, Stephen J.; Moshiri, Mariam; Paun, Marla; Lu, Wei; Bailey, Michael R.
2013-01-01
Abstract Purpose To compare color Doppler twinkling artifact and B-mode ultrasonography in detecting kidney stones. Patients and Methods Nine patients with recent CT scans prospectively underwent B-mode and twinkling artifact color Doppler ultrasonography on a commercial ultrasound machine. Video segments of the upper pole, interpolar area, and lower pole were created, randomized, and independently reviewed by three radiologists. Receiver operator characteristics were determined. Results There were 32 stones in 18 kidneys with a mean stone size of 8.9±7.5 mm. B-mode ultrasonography had 71% sensitivity, 48% specificity, 52% positive predictive value, and 68% negative predictive value, while twinkling artifact Doppler ultrasonography had 56% sensitivity, 74% specificity, 62% positive predictive value, and 68% negative predictive value. Conclusions When used alone, B-mode is more sensitive, but twinkling artifact is more specific in detecting kidney stones. This information may help users employ twinkling and B-mode to identify stones and developers to improve signal processing to harness the fundamental acoustic differences to ultimately improve stone detection. PMID:23067207
Stirrup, James E; Cowburn, Peter J; Pousios, Dimitrios; Ohri, Sunil K; Shah, Benoy N
2016-09-01
Transesophageal echocardiography (TEE) is a powerful imaging tool for the comprehensive assessment of valvular structure and function. TEE may be of added benefit when anatomy is difficult to delineate accurately by transthoracic echocardiography. In this article, we present 2-, 3-dimensional, and color Doppler TEE images from a male patient with aortic stenosis. A highly unusual and complex pattern of valvular calcification created a functionally "double-orifice" valve. Such an abnormality may have implications for the accuracy of continuous-wave Doppler echocardiography, which assumes a single orifice valve in native aortic valves. © 2016, Wiley Periodicals, Inc.
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Zepiridis, L; Zafrakas, M; Theodoridis, T D; Assimakopoulos, E; Tzevelekis, P; Athanatos, D; Bontis, J N; Tarlatzis, B C
2009-12-01
To present a new clinical observation made in three cases of retained adherent placenta, a rare obstetrical complication, associated with potentially life-threatening hemorrhage. Three consecutive cases of retained adherent placenta are presented. Diagnosis of placenta increta in two and placenta percreta in one case was established with ultrasound and MRI. Methotrexate 50 mg i.v. (300 mg total dose) and follinic acid 0.1 mg/kg were administered on alternating days, over 12 days. On follow-up, placental perfusion on color Doppler was present up to the point when circulating hPL levels were no longer detectable; this was followed in all cases by spontaneous placental expulsion within 10 days. The observation that both color Doppler and human placental lactogen can be used to monitor response to therapy and predict placental expulsion should be evaluated in future cases of retained adherent placenta.
Practical application of color Doppler ultrasonography in patients with ejaculatory dysfunction.
Hara, Ryoei; Nagai, Atsushi; Fujii, Tomohiro; Fukumoto, Kazuhiko; Ohira, Shin; Jo, Yoshimasa; Yokoyama, Teruhiko; Miyaji, Yoshiyuki
2015-06-01
We describe two cases in which dynamic analysis of ejaculation using color Doppler ultrasonography was useful in diagnosis of ejaculatory dysfunction and planning of therapy. The first patient was a 32-year-old man with a diagnosis of retrograde ejaculation. A bladder neck collagen injection was carried out, as the main cause was thought to be the bladder neck remaining open during ejaculation. The patient had antegrade ejaculation 1 week later. The second patient was a 48-year-old man with a diagnosis of anorgasmia accompanied by decreased seminal emission and insufficient function of the rhythmic pelvic striated muscles. The patient was prescribed etilefrine hydrochloride 15 mg/day. The symptom improved 2 weeks after starting this drug. These cases suggest that the use of color Doppler ultrasonography during ejaculation can improve the understanding of ejaculatory dysfunction and therapy for this condition. © 2015 The Japanese Urological Association.
Morgan, Tara A; Jha, Priyanka; Poder, Liina; Weinstein, Stefanie
2018-04-09
Ultrasound is routinely used as the first imaging exam for evaluation of renal transplants and can identify most major surgical complications and evaluate vascularity with color Doppler. Ultrasound is limited, however, in the detection of parenchymal disease processes and Doppler evaluation is also prone to technical errors. Multiple new ultrasound applications have been developed and are under ongoing investigation which could add additional diagnostic capability to the routine ultrasound exam with minimal additional time, cost, and patient risk. Contrast-enhanced ultrasound (CEUS) can be used off-label in the transplant kidney, and can assist in detection of infection, trauma, and vascular complications. CEUS also can demonstrate perfusion of the transplant assessed quantitatively with generation of time-intensity curves. Future directions of CEUS include monitoring treatment response and microbubble targeted medication delivery. Elastography is an ultrasound application that can detect changes in tissue elasticity, which is useful to diagnose diffuse parenchymal disease, such as fibrosis, otherwise unrecognizable with ultrasound. Elastography has been successfully applied in other organs including the liver, thyroid, and breast; however, it is still under development for use in the transplant kidney. Unique properties of the transplant kidney including its heterogeneity, anatomic location, and other technical factors present challenges in the development of reference standard measurements. Lastly, B-flow imaging is a flow application derived from B-mode. This application can show the true lumen size of a vessel which is useful to depict vascular anatomy and bypasses some of the pitfalls of color Doppler such as demonstration of slow flow.
[Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].
Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P
1996-01-01
Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.
Buyukkaya, Ramazan; Buyukkaya, Ayla; Ozturk, Beyhan; Kayıkçı, Ali; Yazgan, Ömer
2014-03-01
Penile fracture is the rupture of tunica albuginea, typically resulting from blunt trauma, intercourse, or penile manipulation. Diagnosis is made clinically. Ultrasound is not used frequently in diagnosis of penile fracture but it provides a fast, non-invasive alternative to more often used MRI and cavernography. We aimed to present diagnostic ultrasound and color Doppler images of a patient with acute penile fracture in conjunction with literature.
Color Doppler sonography and angioscintigraphy in hepatic Hodgkin’s lymphoma
Stojković, Mirjana V; Artiko, Vera M; Radoman, Irena B; Knežević, Slavko J; Lukić, Snezana M; Kerkez, Mirko D; Lekić, Nebojsa S; Antić, Andrija A; Žuvela, Marinko M; Ranković, Vitomir I; Petrović, Milorad N; Šobić, Dragana P; Obradović, Vladimir B
2009-01-01
AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin’s hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin’s lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. RESULTS: In the majority of patients, hepatomegaly was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P > 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P < 0.01). HPI was significantly lower in patients with lymphomas than in controls (P < 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin’s hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions. PMID:19598303
Technical Note: A new phantom design for routine testing of Doppler ultrasound.
Grice, J V; Pickens, D R; Price, R R
2016-07-01
The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine testing more approachable for institutions that wish to initiate a Doppler QA program or complement a previously existing QA program.
Overview of the physics of US.
Goldstein, A
1993-05-01
In ultrasonography (US), high-frequency sound waves are transmitted through the body by a transducer. When a transmitted ultrasound pulse encounters a tissue target, some of its energy is deflected back to the transducer. The time of flight of this ultrasound echo is used to calculate depth of the target in the transducer beam. The pulse-echo parameters used in the formation of images include echo amplitude, target spatial position, and frequency shift between the transmitted pulse and the received echo. The first two are displayed in gray-scale images and all three in color flow images. In gray-scale US, echo amplitude is encoded into shades of gray, with the lighter shades representing higher amplitude echoes. In color flow US, velocity of moving blood is usually presented in blue for motion toward the transducer and in red for motion away from it. A Doppler spectrum depicts changing blood velocity as a function of time. US has become more clinically valuable due to its ability to demonstrate soft-tissue structures, real-time imaging capability, relative safety, portability, and cost-effectiveness.
Airborne Doppler Wind Lidar Post Data Processing Software DAPS-LV
NASA Technical Reports Server (NTRS)
Kavaya, Michael J. (Inventor); Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor)
2015-01-01
Systems, methods, and devices of the present invention enable post processing of airborne Doppler wind LIDAR data. In an embodiment, airborne Doppler wind LIDAR data software written in LabVIEW may be provided and may run two versions of different airborne wind profiling algorithms. A first algorithm may be the Airborne Wind Profiling Algorithm for Doppler Wind LIDAR ("APOLO") using airborne wind LIDAR data from two orthogonal directions to estimate wind parameters, and a second algorithm may be a five direction based method using pseudo inverse functions to estimate wind parameters. The various embodiments may enable wind profiles to be compared using different algorithms, may enable wind profile data for long haul color displays to be generated, may display long haul color displays, and/or may enable archiving of data at user-selectable altitudes over a long observation period for data distribution and population.
Fox, P R; Miller, M W; Liu, S K
1992-11-15
Mitral stenosis was diagnosed noninvasively by echocardiography and Doppler imaging in 2 Bull Terriers. Two-dimensional echocardiography revealed severe atrial and moderate left ventricular dilatation; severely reduced mitral valve opening excursion; doming of the cranial mitral valve leaflet into the left ventricle during diastole; thickened, nodular cranial mitral valve leaflets; and reduced mitral valve orifice. M-mode echocardiographic findings additionally indicated greatly diminished mitral valve E to F slope and abnormal caudal mitral valve leaflet motion. Color flow Doppler imaging revealed bright bursts of color with aliasing originating from the stenotic mitral valve orifice, extending into the left atrium during systole, and into the left atrium during diastole. Spectral Doppler recordings revealed transvalvular mitral valve gradients and prolonged pressure half-times. Necropsy performed on 1 dog revealed extremely thickened, nodular, and stiff mitral valves with short, thickened, and fused chordae tendineae. The diagnosis of mitral valve stenosis was easily facilitated with diagnostic ultrasonography.
Pirat, Bahar; Little, Stephen H.; Igo, Stephen R.; McCulloch, Marti; Nosé, Yukihiko; Hartley, Craig J.; Zoghbi, William A.
2012-01-01
Objective The proximal isovelocity surface area (PISA) method is useful in the quantitation of aortic regurgitation (AR). We hypothesized that actual measurement of PISA provided with real-time 3-dimensional (3D) color Doppler yields more accurate regurgitant volumes than those estimated by 2-dimensional (2D) color Doppler PISA. Methods We developed a pulsatile flow model for AR with an imaging chamber in which interchangeable regurgitant orifices with defined shapes and areas were incorporated. An ultrasonic flow meter was used to calculate the reference regurgitant volumes. A total of 29 different flow conditions for 5 orifices with different shapes were tested at a rate of 72 beats/min. 2D PISA was calculated as 2π r2, and 3D PISA was measured from 8 equidistant radial planes of the 3D PISA. Regurgitant volume was derived as PISA × aliasing velocity × time velocity integral of AR/peak AR velocity. Results Regurgitant volumes by flow meter ranged between 12.6 and 30.6 mL/beat (mean 21.4 ± 5.5 mL/beat). Regurgitant volumes estimated by 2D PISA correlated well with volumes measured by flow meter (r = 0.69); however, a significant underestimation was observed (y = 0.5x + 0.6). Correlation with flow meter volumes was stronger for 3D PISA-derived regurgitant volumes (r = 0.83); significantly less underestimation of regurgitant volumes was seen, with a regression line close to identity (y = 0.9x + 3.9). Conclusion Direct measurement of PISA is feasible, without geometric assumptions, using real-time 3D color Doppler. Calculation of aortic regurgitant volumes with 3D color Doppler using this methodology is more accurate than conventional 2D method with hemispheric PISA assumption. PMID:19168322
[Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].
Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia
2012-01-01
Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.
Artifacts in Sonography - Part 3.
Bönhof, Jörg A; McLaughlin, Glen
2018-06-01
As a continuation of parts 1 1 and 2 2, this article discusses artifacts as caused by insufficient temporal resolution, artifacts in color and spectral Doppler sonography, and information regarding artifacts in sonography with contrast agents. There are artifacts that occur in B-mode sonography as well as in Doppler imaging methods and sonography with contrast agents, such as slice thickness artifacts and bow artifacts, shadows, mirroring, and artifacts due to refraction that appear, for example, as double images, because they are based on the same formation mechanisms. In addition, there are artifacts specific to Doppler sonography, such as the twinkling artifact, and method-based motion artifacts, such as aliasing, the ureteric jet, and due to tissue vibration. The artifacts specific to contrast mode include echoes from usually highly reflective structures that are not contrast bubbles ("leakage"). Contrast agent can also change the transmitting signal so that even structures not containing contrast agent are echogenic ("pseudoenhancement"). While artifacts can cause problems regarding differential diagnosis, they can also be useful for determining the diagnosis. Therefore, effective use of sonography requires both profound knowledge and skilled interpretation of artifacts. © Georg Thieme Verlag KG Stuttgart · New York.
Svensson, W E; Pandian, A J; Hashimoto, H
2010-10-01
The aim of this study was to evaluate the use of vascular morphology, around and within the B-mode region of abnormality, for improving the diagnostic accuracy of two of the most common solid breast pathologies. The B-mode and Doppler images of 117 breast cancers and 366 fibroadenomas and lesions with a fibroadenoma-like appearance were reviewed retrospectively and the morphology of the vascular pattern was evaluated. The ratio of external to internal color Doppler, the external vascular pattern and the connecting vessels to internal vessels were assessed and differentiated into benign and malignant vascular patterns. These patterns were correlated with the histological diagnosis. Vascularity was demonstrated in 95 % of cancers and in 46 % of benign lesions with a trend to increasing vascularity in cancers. This provided poor specificity for excluding cancer in fibroadenomas. Variations in vascular pattern were recorded. The observed benign vascular patterns were avascularity, vascularity in the periphery and peripheral marginal vessels connecting with internal vascularity. The observed malignant vascular patterns were radially aligned external vessels with internal vessels being more numerous than external vessels which connected to radial vessels. (Fisher exact test p < 0.0001). Analysis of the vascular morphology improved the sensitivity for identifying cancers from 97 % (B-mode) to 99 % (B-mode and color Doppler) with a minimal reduction in specificity (93.7 to 92.6 %) or accuracy (94.6 to 94.2 %). The presence of vascularity within a lesion, by itself, is no longer a good predictor of malignancy because of the increase in Doppler sensitivity associated with improvements in ultrasound technology. The color Doppler ultrasound vascular pattern morphology improves the accuracy and sensitivity of B-mode image diagnosis, breast cancers and fibroadenomas with a minimal loss of specificity. Any breast lesion with radial rather than marginal connecting vessels should be regarded with suspicion. © Georg Thieme Verlag KG Stuttgart · New York.
Gheorghe, Liana; Iacob, Speranta; Iacob, Razvan; Dumbrava, Mona; Becheanu, Gabriel; Herlea, Vlad; Gheorghe, Cristian; Lupescu, Ioana; Popescu, Irinel
2009-12-01
Small nodules (under 3 cm) detected on ultrasound (US) in cirrhotics represent the most challenging category for noninvasive diagnosis of hepatocellular carcinoma (HCC). To evaluate real-time sonoelastography as a noninvasive tool for the diagnosis of small HCC nodules in cirrhotic patients. 42 cirrhotic patients with 58 nodules (1-3 cm) were evaluated with real-time elastography (Hitachi EUB-6500); the mean intensity of colors red, blue, green were measured using a semi-quantitative method. Analysis of histograms for each color of the sonoelastography images was performed for quantifying the elasticity of nodule tissue in comparison with the cirrhotic liver tissue. AUROC curves were constructed to define the best cut-off points to distinguish malignant features of the nodules. Univariate and multivariate logistic regression analysis was performed. 595 sonoelastography images from 42 patients (25 men; 17 women) were analyzed. The mean age was 56.4 +/- 0.7 years and 69% patients were in Child-Pugh class A, 19% class B, 11% class C. For the mean intensity of green color AUROC=0.81, a cut-off value under 108.7 being diagnostic for HCC with a Sp=91.1%, Se=50%, PPV=92.1%, NPV=47.1%. Mean intensity of blue color proved to be an excellent diagnostic tool for HCC (AUROC=0.94); for a cut-off value greater than 128.9, Sp=92.2%, Se=78.9%, PPV=95.4%, NPV=68%. Independent predictive factors of HCC for a small nodule in cirrhotic patients were: blue color over 128.9 at sonoelastography and hypervascular appearance at Doppler US. US elastography is a promising method for the non-invasive diagnosis of early HCC. Blue color at elastography and hypervascular aspects are independent predictors of HCC.
3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.
Provost, Jean; Papadacci, Clement; Demene, Charlie; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu
2015-08-01
Ultrafast Doppler imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D ultrafast ultrasound imaging, a technique that can produce thousands of ultrasound volumes per second, based on a 3-D plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that noninvasive 3-D ultrafast power Doppler, pulsed Doppler, and color Doppler imaging can be used to perform imaging of blood vessels in humans when using coherent compounding of 3-D tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D ultrafast imaging. Using a 32 × 32, 3-MHz matrix phased array (Vermon, Tours, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. The proof of principle of 3-D ultrafast power Doppler imaging was first performed by imaging Tygon tubes of various diameters, and in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D color and pulsed Doppler imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer.
Provost, J.; Papadacci, C.; Demene, C.; Gennisson, J-L.; Tanter, M.; Pernot, M.
2016-01-01
Ultrafast Doppler Imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D Ultrafast Ultrasound Imaging, a technique that can produce thousands of ultrasound volumes per second, based on three-dimensional plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that non-invasive 3-D Ultrafast Power Doppler, Pulsed Doppler, and Color Doppler Imaging can be used to perform quantitative imaging of blood vessels in humans when using coherent compounding of three-dimensional tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D Ultrafast Imaging. Using a 32X32, 3-MHz matrix phased array (Vermon, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. 3-D Ultrafast Power Doppler Imaging was first validated by imaging Tygon tubes of varying diameter and its in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D Color and Pulsed Doppler Imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer. PMID:26276956
Kleinman, J P; Czer, L S; DeRobertis, M; Chaux, A; Maurer, G
1989-11-15
Epicardial and transesophageal color Doppler echocardiography are both widely used for the intraoperative assessment of mitral regurgitation (MR); however, it has not been established whether grading of regurgitation is comparable when evaluated by these 2 techniques. MR jet size was quantitatively compared in 29 hemodynamically and temporally matched open-chest epicardial and transesophageal color Doppler echocardiography studies from 22 patients (18 with native and 4 with porcine mitral valves) scheduled to undergo mitral valve repair or replacement. Jet area, jet length and left atrial area were analyzed. Comparison of jet area measurements as assessed by epicardial and transesophageal color flow mapping revealed an excellent correlation between the techniques (r = 0.95, p less than 0.001). Epicardial and transesophageal jet length measurements were also similar (r = 0.77, p less than 0.001). Left atrial area could not be measured in 18 transesophageal studies (62%) due to foreshortening, and in 5 epicardial studies (17%) due to poor image resolution. Acoustic interference with left atrial and color flow mapping signals was noted in all patients with mitral valve prostheses when imaged by epicardial echocardiography, but this did not occur with transesophageal imaging. Thus, in patients undergoing valve repair or replacement, transesophageal and epicardial color flow mapping provide similar quantitative assessment of MR jet size. Jet area to left atrial area ratios have limited applicability in transesophageal color flow mapping, due to foreshortening of the left atrial borders in transesophageal views. Transesophageal color flow mapping may be especially useful in assessing dysfunctional mitral prostheses due to the lack of left atrial acoustic interference.
Real-time high-velocity resolution color Doppler OCT
NASA Astrophysics Data System (ADS)
Westphal, Volker; Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.
2001-05-01
Color Doppler optical coherence tomography (CDOCT), also called Optical Doppler Tomography) is a noninvasive optical imaging technique, which allows for micron-scale physiological flow mapping simultaneous with morphological OCT imaging. Current systems for real-time endoscopic optical coherence tomography (EOCT) would be enhanced by the capability to visualize sub-surface blood flow for applications in early cancer diagnosis and the management of bleeding ulcers. Unfortunately, previous implementations of CDOCT have either been sufficiently computationally expensive (employing Fourier or Hilbert transform techniques) to rule out real-time imaging of flow, or have been restricted to imaging of excessively high flow velocities when used in real time. We have developed a novel Doppler OCT signal-processing strategy capable of imaging physiological flow rates in real time. This strategy employs cross-correlation processing of sequential A-scans in an EOCT image, as opposed to autocorrelation processing as described previously. To measure Doppler shifts in the kHz range using this technique, it was necessary to stabilize the EOCT interferometer center frequency, eliminate parasitic phase noise, and to construct a digital cross correlation unit able to correlate signals of megahertz bandwidth by a fixed lag of up to a few ms. The performance of the color Doppler OCT system was demonstrated in a flow phantom, demonstrating a minimum detectable flow velocity of ~0.8 mm/s at a data acquisition rate of 8 images/second (with 480 A-scans/image) using a handheld probe. Dynamic flow as well as using it freehanded was shown. Flow was also detectable in a phantom in combination with a clinical usable endoscopic probe.
Examples of Radiation-Emitting Products
... Ultrasonography • Doppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...
Imaging in gynecological disease (9): clinical and ultrasound characteristics of tubal cancer.
Ludovisi, M; De Blasis, I; Virgilio, B; Fischerova, D; Franchi, D; Pascual, M A; Savelli, L; Epstein, E; Van Holsbeke, C; Guerriero, S; Czekierdowski, A; Zannoni, G; Scambia, G; Jurkovic, D; Rossi, A; Timmerman, D; Valentin, L; Testa, A C
2014-03-01
To describe clinical history and ultrasound findings in patients with tubal carcinoma. Patients with a histological diagnosis of tubal cancer who had undergone preoperative ultrasound examination were identified from the databases of 13 ultrasound centers. The tumors were described by the principal investigator at each contributing center on the basis of ultrasound images, ultrasound reports and research protocols (when applicable) using the terms and definitions of the International Ovarian Tumor Analysis (IOTA) group. In addition, three authors reviewed together all available digital ultrasound images and described them using subjective evaluation of gray-scale and color Doppler ultrasound findings. We identified 79 women with a histological diagnosis of primary tubal cancer, 70 of whom (89%) had serous carcinomas and 46 (58%) of whom presented at FIGO stage III. Forty-nine (62%) women were asymptomatic (incidental finding), whilst the remaining 30 complained of abdominal bloating or pain. Fifty-three (67%) tumors were described as solid at ultrasound examination, 14 (18%) as multilocular solid, 10 (13%) as unilocular solid and two (3%) as unilocular. No tumor was described as a multilocular mass. Most tumors (70/79, 89%) were moderately or very well vascularized on color or power Doppler ultrasound. Normal ovarian tissue was identified adjacent to the tumor in 51% (39/77) of cases. Three types of ultrasound appearance were identified as being typical of tubal carcinoma using pattern recognition: a sausage-shaped cystic structure with solid tissue protruding into it like a papillary projection (11/62, 18%); a sausage-shaped cystic structure with a large solid component filling part of the cyst cavity (13/62, 21%); an ovoid or oblong completely solid mass (36/62, 58%). A well vascularized ovoid or sausage-shaped structure, either completely solid or with large solid component(s) in the pelvis, should raise the suspicion of tubal cancer, especially if normal ovarian tissue is seen adjacent to it. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Dhutia, Niti M.; Zolgharni, Massoud; Willson, Keith; Cole, Graham; Nowbar, Alexandra N.; Manisty, Charlotte H.; Francis, Darrel P.
2014-03-01
Some of the challenges with tissue Doppler measurement include: apparent inconsistency between manufacturers, uncertainty over which part of the trace to make measurements and a lack of calibration of measurements. We develop and test tools to solve these problems in echocardiography laboratories. We designed and constructed an actuator and phantom setup to produce automatic reproducible motion, and used it to compare velocities measured using 3 echocardiographic modalities: M-mode, speckle tracking, and tissue Doppler, against a non-ultrasound, optical gold standard. In the clinical phase, 25 patients underwent M-mode, speckle tracking and tissue Doppler measurements of tissue velocities. In-vitro, the M-mode and speckle tracking velocities were concordant with optical assessment. Of the three possible tissue Doppler measurement conventions (outer, middle and inner line) only the middle line agreed with the optical assessment (discrepancy -0.20 (95% confidence interval -0.44 to 0.03)cm/s, p=0.11, outer +5.19(4.65 to 5.73)cm/s, p<0.0001, inner -6.26(-6.87 to -5.65)cm/s, p<0.0001). All 4 studied manufacturers showed a similar pattern. M-mode was therefore chosen as the in-vivo gold standard. Clinical measurements of tissue velocities by speckle tracking and the middle line of the tissue Doppler were concordant with M-mode, while the outer line significantly overestimated (+1.27(0.96 to 1.59)cm/s, p<0.0001) and the inner line underestimated (-1.81(-2.11 to -1.52)cm/s, p<0.0001). Echocardiographic velocity measurements can be calibrated by simple, inexpensive tools. We found that the middle of the tissue Doppler trace represents velocity correctly. Echocardiographers requiring velocities to match between different equipment, settings or modalities should use the middle line as the "guideline".
A simple method to treat post-kydney transplantation lymphocele.
Damiano, G; Lombardo, C; Palumbo, V D; Buffa, D; Maione, C; Gioviale, M C; Cacciabaudo, F; Spinelli, G; Calvagna, C; Lo Monte, A I
2011-01-01
To describe our experience with ultrasonic-guided instillation of povidone-iodine to treat post-kidney transplantation lymphocele. Patients and methods. We studied the safety and efficacy of this procedure for treatment of lymphocele in 6 male kidney transplanted recipients in which we assisted a progressive increase of creatinine and urinary proteins levels and color-Doppler ultrasonography demonstrated an increase (25,4%) of index of resistence (IR) Using eco-colorDoppler, the related-graft lymphocele location and the distance to the anterior abdominal wall were determined; then, a radiopaque double-lumen catheter was used to instillate 5% povidone-iodine 10 ml. Results. Percutaneous drainage achieved a resolution rate of 100%. Studying the rate of peripheral and internal vascularization of the kidney before and after treatment, eco-colorDoppler showed a significant decrease of the IR (24,6%). Conclusions. The US-guided povidone-iodine instillation for treatment of lymphocele following renal transplantation may be considered as first choice therapy in such disease.
Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y
1997-09-01
Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.
True Brachial Artery Aneurysm Presenting as a Non-Pulsatile Mass.
Pradhananga, A; Chao, X
2017-01-01
Brachial artery aneurysms are rare disease that can be encountered. It is divided into true and false. The frequency of true aneurysm of the brachial artery is so much unusual. So, we present a case of a 59 year old male who presented to us with complaint of mass in left upper limb since many years ago. Now, there was sudden onset of progressive pain with coldness, numbness, tingling sensation and blackish discolouration of skin from 8 hours. The left upper limb was pulseless and color Doppler ultrasound showed a non-pulsatile aneurysm at the mid level of left brachial artery associated with arterial occlusion in its distal branch by thrombus. The patient was successfully revascularised by interposing a saphenous vein graft. Thus,this case suggest that the prompt diagnosis of true brachial artery aneurysm by ultrasound or color Doppler ultrasound and the proper treatment by surgical repair can save limb from dangerous sequel Keywords: brachial artery aneurysm; color doppler ultrasound; true aneurysm; ultrasound.
Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking.
Fadnes, Solveig; Nyrnes, Siri Ann; Torp, Hans; Lovstakken, Lasse
2014-10-01
High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Twinkling artifact on color Doppler ultrasound: an advantage or a pitfall?
Ozan, Ebru; Atac, Gokce Kaan; Gundogdu, Sadi
2016-07-01
The twinkling artifact (TA) or color comet-tail artifact is characterized by a rapidly changing mixture of red and blue color Doppler signals. Even though many diseases and clinical conditions have been shown to produce this artifact, its source is not clearly understood yet. The TA may provide additional information to gray-scale ultrasound findings in several clinical situations. However, there may be pitfalls to keep in mind. We must first be aware of the TA to benefit from the advantages and avoid the pitfalls. In this review, we aim to give practicing radiologists an overview of the mechanisms and clinical applications of the TA by illustrating sample cases we have encountered.
Costa, Ana Paula Araujo; Lima, Aline Maria Vasconcelos; da Silva, Luiz Henrique; de Oliveira Alves Carvalho, Rosângela; do Amaral, Andréia Vitor Couto; Borges, Naida Cristina
2016-07-22
It has been proposed that sildenafil citrate can increase ocular blood flow, and that this property can be used to treat ocular disorders that involve reflex vasoconstriction. This study therefore proposes to ascertain the vasodilator effect of the drug on retrobulbar circulation in healthy rabbits. For this matter rabbits treated with sildenafil citrate or saline solution had their intraocular pressure (IOP), mean arterial pressure (MAP), ocular perfusion pressure (OPP) and color Doppler imaging of the external ophthalmic artery measured prior to treatment and on days one (moment M1), seven (when M2), fourteen (moment M3), twenty-one (moment M4), and thirty (moment M5) of treatment. The MAP and OPP values of treated group were lower than those of control group at all times, and the mean values differed statistically at moments M1 (S = 71.52 mmHg, C = 84.76 mmHg, p = 0.0356) and M5 (S = 71.38 mmHg, C = 85.52 mmHg, p = 0.0252). The IOP and color Doppler values of the external ophthalmic artery did not differ between tested groups. The dose of 10 mg of sildenafil citrate administered to healthy rabbits causes systemic vasodilation and consequently lower values of MAP and OPP. However, it does not induce changes in IOP and retrobulbar hemodynamics identifiable by color Doppler assessment of the external ophthalmic artery.
Color Doppler quantitative measures to predict outcome of biopsies in prostate cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strigari, Lidia; Marsella, Annelisa; Canitano, Stefano
2008-11-15
Purpose: The aim was to correlate the color Doppler flow activity pre- and postradiotherapy, using transrectal color Doppler ultrasonography (CDUS) and the 2 year positive biopsy rate after radiotherapy in patients with prostate cancer. Methods and materials: Analysis was carried out in 69 out of 160 patients who had undergone treatment with 3D-conformal radiotherapy (3D-CRT) to prostate and seminal vesicles. Patients were randomized to receive 80 Gy in 40 fractions in 8 weeks (arm A) and 62 Gy in 20 fractions in 5 weeks, 4 fractions per week (arm B). Color Doppler flow activity (CDFA) was evaluated calculating the vascularizationmore » index (VI), defined as the ratio between the colored and total pixels in the whole and peripheral prostate, delineated by a radiation oncologist on CDUS images, using EcoVasc a home-made software. The difference between the 2 year post- and pre-3D-CRT maximum VI (VI{sub max}), named {Delta}VI{sub max}, was calculated in the whole and peripheral prostate for each patient. Then, {Delta}VI{sub max} and the detected 2 year biopsy outcome were analyzed using the receiver operating characteristics (ROC) technique. Results: The VI{sub max} increased or decreased in patients with positive or negative biopsies, respectively, compared to the value before RT in both arms. The area under the ROC curve for {Delta}VI{sub max} in the whole and peripheral prostate is equal to 0.790 and 0.884, respectively. Conclusion: The {Delta}VI{sub max} index, comparing CDFA at 2 years compared to that before RT, allows the 2 year postradiotherapy positive biopsy rate to be predicted.« less
Görges, Rainer; Eising, E G; Fotescu, D; Renzing-Köhler, K; Frilling, A; Schmid, K W; Bockisch, A; Dirsch, O
2003-02-01
Ultrasonography is an established diagnostic modality in the follow-up of thyroid cancer. Color flow Doppler has been proposed by some authors as an additional tool for differentiating benign from malignant cervical lesions in various types of head and neck cancer. Over the last few years, a new generation of high-resolution ultrasound platforms with the "power-mode" feature has become available, that also enables the imaging of small vessel blood flow. The objective of our study was to find ways of optimizing the differentiation of benign and malignant cervical tumors in thyroid cancer follow-up by means of sonography. Hundred and twelve cervical lesions in 90 patients with thyroid cancer were evaluated by high-end ultrasonography (Sonoline Elegra, Siemens) using a small-part transducer (7.5 L 40, Siemens). B-mode sonography was performed at a frequency of 8 MHz. The Solbiati index (SI= ratio of largest to smallest diameter), configuration, echogenicity, intranodular structures, and margins were assessed. Perinodular and intranodular blood flow was evaluated by color flow Doppler (PRF 1250 Hz for conventional color flow Doppler, 868 Hz for power-mode Doppler). Possible malignancy was validated by histology, cytology, scintigraphy, and follow-up. Thirty five lesions were benign (diameter 0.4-3.0 cm) and 77 were malignant (0.4-5.4 cm). The patients were randomized into a test group and a learning group to determine the diagnostic value of various ultrasound criteria by means of statistical analysis. In the learning group, decision rules based on the dichotomized criteria were developed using a logistic regression model. Sensitivity and specificity of these decision rules were then evaluated in the test group. The presence of an echocomplex pattern or irregular hyperechoic small intranodular structures (criterion A) and the presence of an irregular diffuse intranodular blood flow (criterion B) are the best indicators of malignancy, whereas an SI >2 is highly indicative of benign changes. Color flow Doppler is a useful addition to B-mode scanning for distinguishing benign and malignant neoplasms in the follow-up of thyroid cancer. Power-mode Doppler sonography significantly improves imaging of perinodular and intranodular blood flow when compared with conventional color flow Doppler. We propose the following decision rules based on a combination of the criteria above: (A) and (B) fulfilled: malignant, if SI< or =4; (B) but not (A) fulfilled: malignant, if SI< or =3; (A) but not (B) fulfilled: malignant, if SI< or =2; neither (A) nor (B) fulfilled: malignant, if SI approximately equal to 1 (sensitivity: 90%; specificity: 82%; accuracy 88%).
21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... determine stationary body tissue characteristics, such as depth or location of tissue interfaces or dynamic...
Tarantino, Luciano; Francica, Giampiero; Sordelli, Ignazio; Sperlongano, Pasquale; Parmeggiani, Domenico; Ripa, Carmine; Parmeggiani, Umberto
2008-03-01
The purpose of this study was to assess the long-term efficacy of percutaneous ethanol injection (PEI) for the treatment of hyperfunctioning thyroid nodules. One hundred twenty-five patients (88 women, 37 men; age range, 17-76 years; mean age, 53 years) with 127 hyperfunctioning thyroid nodules (volume, 1.2-90 mL; mean, 10.3 mL) were treated with PEI. There were 1-11 PEI sessions per patient (average, 3.9) performed, with injection of 1-14 mL of ethanol per session (total injected ethanol per patient, 3-108 mL; mean, 14.0 mL). Efficacy of the treatment was assessed with color Doppler sonography; scintigraphy; and free triiodothyronine (FT3), free thyroxine (FT4), and thyroid-stimulating hormone (TSH) assays. Follow-up (9-144 months; median, 60 months) was performed with TSH and color Doppler sonography every 2 months for 6 months and every 6 months thereafter. Three (2.4%) of 125 patients refused completion of PEI therapy because of pain. Results are reported in 122 patients with 124 nodules. All 122 patients showed posttreatment normal levels of FT3, FT4, and TSH. A complete cure (absent uptake in the nodule and recovery of normal uptake in the thyroid parenchyma) was obtained in 113 (93%) of 122 patients-115 (92.7%) of 124 treated nodules. Residual hyperfunctioning nodular tissue along with decreased thyroid parenchyma uptake (partial cure) was present in nine patients accounting for nine (7.3%) of 124 nodules. Rates of complete cure after PEI were: overall nodules, 115 (92.7%) of 124; nodules < or = 10 mL, 63 (94.0%) of 67; nodules > 10 to < or = 30 mL, 32 (91.4%) of 35; nodules > 30 to < or = 60 mL, 17 (89.5%) of 19; nodules > 60 mL, three (100%) of three. The overall rate of major complications (transient laryngeal nerve damage, two patients; abscess and hematoma, one patient each) was four (3.2%) of 125 patients. Follow-up examinations showed marked shrinkage of 112 treated nodules ranging from 50% to 90% of the pretreatment volume (mean, 66%) and new growth of hyperfunctioning tissue in four patients at color Doppler sonography and scintigraphy at 12, 18, 18, and 48 months' follow-up, respectively. However, all patients remained euthyroid (low or normal TSH and normal FT3 and FT4) during follow-up. PEI of hyperfunctioning thyroid nodules seems to be an effective and safe alternative to traditional treatment. It also appears to be effective in patients with hyperfunctioning thyroid nodules larger than 30 mL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cullen, D.E.
1977-01-12
A code, SIGMA1, has been designed to Doppler broaden evaluated cross sections in the ENDF/B format. The code can only be applied to tabulated data that vary linearly in energy and cross section between tabulated points. This report describes the methods used in the code and serves as a user's guide to the code.
Noninvasive imaging analysis of biological tissue associated with laser thermal injury.
Chang, Cheng-Jen; Yu, De-Yi; Hsiao, Yen-Chang; Ho, Kuang-Hua
2017-04-01
The purpose of our study is to use a noninvasive tomographic imaging technique with high spatial resolution to characterize and monitor biological tissue responses associated with laser thermal injury. Optical doppler tomography (ODT) combines laser doppler flowmetry (LDF) with optical coherence tomography (OCT) to obtain high resolution tomographic velocity and structural images of static and moving constituents in highly scattering biological tissues. A SurgiLase XJ150 carbon dioxide (CO 2 ) laser using a continuous mode of 3 watts (W) was used to create first, second or third degree burns on anesthetized Sprague-Dawley rats. Additional parameters for laser thermal injury were assessed as well. The rationale for using ODT in the evaluation of laser thermal injury offers a means of constructing a high resolution tomographic image of the structure and perfusion of laser damaged skin. In the velocity images, the blood flow is coded at 1300 μm/s and 0 velocity, 1000 μm/s and 0 velocity, 700 μm/s and 0 velocity adjacent to the first, second, and third degree injuries, respectively. ODT produces exceptional spatial resolution while having a non-invasive way of measurement, therefore, ODT is an accurate measuring method for high-resolution fluid flow velocity and structural images for biological tissue with laser thermal injury. Copyright © 2017 Chang Gung University. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Hoch, Edward L.; Hallinan, Thomas J.; Stenbaek-Nielsen, Hans C.
1994-01-01
Intensity-calibrated color video recordings of three barium-shaped charge injections in the ionopshere were used to determine the initial ionization, the column density corresponding to unity optical depth, and the yield of vaporized barium in the fast jet. It was found that the initial ionization at the burst was less than 1% and that 0% burst ionization was consistent with the observations. Owing to the Doppler shift, the column density for optical thickness in the neutral barium varies somewhat according to the velocity distribution. For the cases examined here, the column density was 2-5 x 10(exp 10) atoms/sq cm. This value, which occurred 12 to 15 s after release, should be approximately valid for most shaped charge experiments. The yield was near 30% (15% in the fast jet) for two of the releases and was somewhat lower in the third, which also had a lower peak velocity. This study also demonstrated the applicability of the computer simulation code developed for chemical releases by Stenbaek-Nielsen and provided experimental verification of the Doppler-corrected emission rates calculated b Stenbaek-Nielsen (1989).
Color Doppler ultrasound evaluation of testicular blood flow in stallions.
Pozor, M A; McDonnell, S M
2004-04-01
The objectives of this study were to evaluate the potential use of color Doppler ultrasound to characterize blood flow to the stallion testis, and to establish reference values for Doppler measures of blood flow in the testicular artery of the stallion. Both testes from each of 52 horses were examined using a pulsed-wave color Doppler ultrasound with a sector array 5/7.5 MHz transducer with a 1mm gate setting. Peak systolic velocity (PSV), end diastolic velocity (EDV), resistive index (RI), and pulsatility index (PI) of the testicular artery were measured in each of two locations, the convoluted aspect (spermatic cord) and the marginal aspect of the artery (on the epididymal edge of testis). We found that: (1) all measures were obtainable; (2) except for EDV, the majority of the measures were higher at the cord location than at the marginal aspect of the artery (P < 0.05); and (3) measures for left and right testes were similar (P > 0.10). Resulting measures from 41 of these stallions (82 testes) that appeared free of testicular pathology provide useful reference values for clinical evaluation. Evaluation of 11 cases with testicular pathology suggested further investigation of possible effects of these various conditions on testicular blood flow and testicular function.
Lei, M H; Chen, J J; Ko, Y L; Cheng, J J; Kuan, P; Lien, W P
1995-01-01
This study assessed the usefulness of continuous wave Doppler echocardiography and color flow mapping in evaluating pulmonary regurgitation (PR) and estimating pulmonary artery (PA) pressure. Forty-three patients were examined, and high quality Doppler spectral recordings of PR were obtained in 32. All patients underwent cardiac catheterization, and simultaneous PA and right ventricular (RV) pressures were recorded in 17. Four Doppler regurgitant flow velocity patterns were observed: pandiastolic plateau, biphasic, peak and plateau, and early diastolic triangular types. The peak diastolic and end-diastolic PA-to-RV pressure gradients derived from the Doppler flow profiles correlated well with the catheter measurements (r = 0.95 and r = 0.95, respectively). As PA pressure increased, the PR flow velocity became higher; a linear relationship between either systolic or mean PA pressure and Doppler-derived peak diastolic pressure gradient was noted (r = 0.90 and 0.94, respectively). Based on peak diastolic gradients of < 15, 15-30 or > 30 mm Hg, patients could be separated as those with mild, moderate or severe pulmonary hypertension, respectively (p < 0.05). A correlation was also observed between PA diastolic pressure and Doppler-derived end-diastolic pressure gradient (r = 0.91). Moreover, the Doppler velocity decay slope of PR closely correlated with that derived from the catheter method (r = 0.98). The decay slope tended to be steeper with the increment in regurgitant jet area and length obtained from color flow mapping. In conclusion, continuous wave Doppler evaluation of PR is a useful means for noninvasive estimation of PA pressure, and the Doppler velocity decay slope seems to reflect the severity of PR.
Spread-Spectrum Beamforming and Clutter Filtering for Plane-Wave Color Doppler Imaging.
Mansour, Omar; Poepping, Tamie L; Lacefield, James C
2016-07-21
Plane-wave imaging is desirable for its ability to achieve high frame rates, allowing the capture of fast dynamic events and continuous Doppler data. In most implementations of plane-wave imaging, multiple low-resolution images from different plane wave tilt angles are compounded to form a single high-resolution image, thereby reducing the frame rate. Compounding improves the lateral beam profile in the high-resolution image, but it also acts as a low-pass filter in slow time that causes attenuation and aliasing of signals with high Doppler shifts. This paper introduces a spread-spectrum color Doppler imaging method that produces high-resolution images without the use of compounding, thereby eliminating the tradeoff between beam quality, maximum unaliased Doppler frequency, and frame rate. The method uses a long, random sequence of transmit angles rather than a linear sweep of plane wave directions. The random angle sequence randomizes the phase of off-focus (clutter) signals, thereby spreading the clutter power in the Doppler spectrum, while keeping the spectrum of the in-focus signal intact. The ensemble of randomly tilted low-resolution frames also acts as the Doppler ensemble, so it can be much longer than a conventional linear sweep, thereby improving beam formation while also making the slow-time Doppler sampling frequency equal to the pulse repetition frequency. Experiments performed using a carotid artery phantom with constant flow demonstrate that the spread-spectrum method more accurately measures the parabolic flow profile of the vessel and outperforms conventional plane-wave Doppler in both contrast resolution and estimation of high flow velocities. The spread-spectrum method is expected to be valuable for Doppler applications that require measurement of high velocities at high frame rates.
Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A
2016-01-01
Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.
NASA Astrophysics Data System (ADS)
Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.
2013-03-01
Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.
Quantitative Doppler Analysis Using Conventional Color Flow Imaging Acquisitions.
Karabiyik, Yucel; Ekroll, Ingvild Kinn; Eik-Nes, Sturla H; Lovstakken, Lasse
2018-05-01
Interleaved acquisitions used in conventional triplex mode result in a tradeoff between the frame rate and the quality of velocity estimates. On the other hand, workflow becomes inefficient when the user has to switch between different modes, and measurement variability is increased. This paper investigates the use of power spectral Capon estimator in quantitative Doppler analysis using data acquired with conventional color flow imaging (CFI) schemes. To preserve the number of samples used for velocity estimation, only spatial averaging was utilized, and clutter rejection was performed after spectral estimation. The resulting velocity spectra were evaluated in terms of spectral width using a recently proposed spectral envelope estimator. The spectral envelopes were also used for Doppler index calculations using in vivo and string phantom acquisitions. In vivo results demonstrated that the Capon estimator can provide spectral estimates with sufficient quality for quantitative analysis using packet-based CFI acquisitions. The calculated Doppler indices were similar to the values calculated using spectrograms estimated on a commercial ultrasound scanner.
Chetboul, Valérie; Blot, Stephane; Sampedrano, Carolina Carlos; Thibaud, Jean-Laurent; Granger, Nicolas; Tissier, Renaud; Bruneval, Patrick; Gaschen, Frederic; Gouni, Vassiliki; Nicolle, Audrey P; Pouchelon, Jean-Louis
2006-01-01
Diagnosis of feline hypertrophic cardiomyopathy currently is based on the presence of myocardial hypertrophy detected using conventional echocardiography. The accuracy of tissue Doppler imaging (TDI) for earlier detection of the disease has never been described. The objective of this sudy was to quantify left ventricular free wall (LVFW) velocities in cats with hypertrophic muscular dystrophy (HFMD) during preclinical cardiomyopathy using TDI. The study animals included 22 healthy controls and 7 cats belonging to a family of cats with HFMD (2 affected adult males, 2 heterozygous adult females, one 2.5-month-old affected male kitten, and 2 phenotypically normal female kittens from the same litter). All cats were examined via conventional echocardiography and 2-dimensional color TDI. No LVFW hypertrophy was detected in the 2 carriers or in the affected kitten when using conventional echocardiography and histologic examination, respectively. The LVFW also was normal for 1 affected male and at the upper limit of normal for the 2nd male. Conversely, LVFW dysfunction was detected in all affected and carrier cats with HFMD when using TDI. TDI consistently detects LVFW dysfunction in cats with HFMD despite the absence of myocardial hypertrophy. Therefore, TDI appears more sensitive than conventional echocardiography in detecting regional myocardial abnormalities.
Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P
2016-10-01
The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard
2017-04-01
Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.
Xuan, Xu-Jun; Bai, Gang; Zhang, Cai-Xia; Xu, Chao; Lu, Fu-Ding; Peng, Yang; Ma, Gang; Han, Cong-Hui; Chen, Jun
2016-01-01
We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg), prostaglandin E1 (10 μg), and lidocaine (2%, 0.5–1 ml), the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades V to II). Then, the patients were given oral sildenafil (50–100 mg) and scored according to the International Index of Erectile Function (IIEF-5) questionnaire. The number of patients with penile rigidities of Schramek Grades II to V was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P < 0.05), the peak systolic velocity (r = 0.45, P < 0.05), and penile rigidity (r = 0.75, P < 0.05), and was negatively correlated with the end diastolic velocity (r = −0.74, P < 0.05). For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction. PMID:25994651
Sikdar, Siddhartha; Shah, Jay P.; Gebreab, Tadesse; Yen, Ru-Huey; Gilliams, Elizabeth; Danoff, Jerome; Gerber, Lynn H.
2009-01-01
Objective Apply ultrasound (US) imaging techniques to better describe the characteristics of myofascial trigger points (MTrPs) and the immediately adjacent soft tissue. Design Descriptive (exploratory) study. Setting Biomedical research center. Participants 9 subjects meeting Travell and Simons’s criteria for MTrPs in a taut band in the upper trapezius. Interventions (None) Main Outcome Measures MTrPs were evaluated by 1) physical examination, 2) pressure algometry, and 3) three types of ultrasound imaging including grayscale (2D US), vibration sonoelastography (VSE), and Doppler. Methods Four sites in each patient were labeled based on physical examination as either active MTrP (spontaneously-painful, A-MTrP), latent MTrP (non-painful, L-MTrP), or normal myofascial tissue. US examination was performed on each subject by a team blinded to the physical findings. A 12-5 MHz US transducer was used. VSE was performed by color Doppler variance imaging while simultaneously inducing vibrations (~92Hz) with a handheld massage vibrator. Each site was assigned a tissue imaging score (TIS) as follows: 0 = uniform echogenicity and stiffness; 1 = focal hypoechoic region with stiff nodule; 2 = multiple hypoechoic regions with stiff nodules. Blood flow in the neighborhood of MTrPs was assessed using Doppler imaging. Each site was assigned a blood flow waveform score (BFS) as follows: 0 = normal arterial flow in muscle; 1 = elevated diastolic flow; 2 = high-resistance flow waveform with retrograde diastolic flow. Results MTrPs appeared as focal, hypoechoic regions on 2D US, indicating local changes in tissue echogenicity, and as focal regions of reduced vibration amplitude on VSE, indicating a localized stiff nodule. MTrPs were elliptical in shape, with a size of 0.16 ± 0.11 cm2. There were no significant differences in size between A-MTrPs and L-MTrPs. Sites containing MTrPs were more likely to have higher TIS compared to normal myofascial tissue (p<0.002). Small arteries (or enlarged arterioles) near A-MTrPs showed retrograde flow in diastole indicating a highly resistive vascular bed. A-MTrP sites were more likely to have higher BFS compared to L-MTrPs (p<0.021). Conclusions Preliminary findings show that, under the conditions of this investigation, US imaging techniques can be used to distinguish myofascial tissue containing MTrPs from normal myofascial tissue (lacking trigger points). Ultrasound enables visualization and some characterization of MTrPs and adjacent soft tissue. PMID:19887205
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cullen, D.E.
1978-07-04
The code SIGMA1 Doppler broadens evaluated cross sections in the ENDF/B format. The code can be applied only to data that vary as a linear function of energy and cross section between tabulated points. This report describes the methods used in the code and serves as a user's guide to the code. 6 figures, 2 tables.
Kimura, Sumito; Streiff, Cole; Zhu, Meihua; Shimada, Eriko; Datta, Saurabh; Ashraf, Muhammad; Sahn, David J
2014-02-01
The aim of this study was to assess the accuracy, feasibility, and reproducibility of determining stroke volume from a novel 3-dimensional (3D) color Doppler flow quantification method for mitral valve (MV) inflow and left ventricular outflow tract (LVOT) outflow at different stroke volumes when compared with the actual flow rate in a pumped porcine cardiac model. Thirteen freshly harvested pig hearts were studied in a water tank. We inserted a latex balloon into each left ventricle from the MV annulus to the LVOT, which were passively pumped at different stroke volumes (30-80 mL) using a calibrated piston pump at increments of 10 mL. Four-dimensional flow volumes were obtained without electrocardiographic gating. The digital imaging data were analyzed offline using prototype software. Two hemispheric flow-sampling planes for color Doppler velocity measurements were placed at the MV annulus and LVOT. The software computed the flow volumes at the MV annulus and LVOT within the user-defined volume and cardiac cycle. This novel 3D Doppler flow quantification method detected incremental increases in MV inflow and LVOT outflow in close agreement with pumped stroke volumes (MV inflow, r = 0.96; LVOT outflow, r = 0.96; P < .01). Bland-Altman analysis demonstrated overestimation of both (MV inflow, 5.42 mL; LVOT outflow, 4.46 mL) with 95% of points within 95% limits of agreement. Interobserver variability values showed good agreement for all stroke volumes at both the MV annulus and LVOT. This study has shown that the 3D color Doppler flow quantification method we used is able to compute stroke volumes accurately at the MV annulus and LVOT in the same cardiac cycle without electrocardiographic gating. This method may be valuable for assessment of cardiac output in clinical studies.
Imaging thermal expansion and retinal tissue changes during photocoagulation by high speed OCT
Müller, Heike H.; Ptaszynski, Lars; Schlott, Kerstin; Debbeler, Christina; Bever, Marco; Koinzer, Stefan; Birngruber, Reginald; Brinkmann, Ralf; Hüttmann, Gereon
2012-01-01
Visualizing retinal photocoagulation by real-time OCT measurements may considerably improve the understanding of thermally induced tissue changes and might enable a better reproducibility of the ocular laser treatment. High speed Doppler OCT with 860 frames per second imaged tissue changes in the fundus of enucleated porcine eyes during laser irradiation. Tissue motion, measured by Doppler OCT with nanometer resolution, was correlated with the temperature increase, which was measured non-invasively by optoacoustics. In enucleated eyes, the increase of the OCT signal near the retinal pigment epithelium (RPE) corresponded well to the macroscopically visible whitening of the tissue. At low irradiance, Doppler OCT revealed additionally a reversible thermal expansion of the retina. At higher irradiance additional movement due to irreversible tissue changes was observed. Measurements of the tissue expansion were also possible in vivo in a rabbit with submicrometer resolution when global tissue motion was compensated. Doppler OCT may be used for spatially resolved measurements of retinal temperature increases and thermally induced tissue changes. It can play an important role in understanding the mechanisms of photocoagulation and, eventually, lead to new strategies for retinal laser treatments. PMID:22567594
Cow's milk allergy: color Doppler ultrasound findings in infants with hematochezia.
Epifanio, Matias; Spolidoro, Jose Vicente; Missima, Nathalia Guarienti; Soder, Ricardo Bernardi; Garcia, Pedro Celiny Ramos; Baldisserotto, Matteo
2013-01-01
ultrasound (US) has been an important diagnostic tool to identify several causes of gastrointestinal bleeding. Infants with cow's milk allergy (CMA) may present hematochezia and the confirmation of the diagnosis can be difficult. The aim of this study is to describe grayscale and color Doppler ultrasound findings in patients with CMA. we retrospectively studied 13 infants with CMA. All infants presented severe hematochezia and abdominal pain. All underwent an US study with the diagnosis of allergic colitis. This diagnosis was based on clinical findings, recovery after infant or mother exclusion diets in the case of exclusive breastfeeding and positive oral challenge test. the mean age ranged from 1 to 6 months (mean=3.53). Seven out of 13 infants (53.8%) had grayscale and color Doppler sonographic repeated after exclusion diet. Twelve out of 13 (92,3%) showed abnormalities at US and CDUS at beginning. The positive findings suggesting colitis were thickened bowel walls and increased vascularity, especially in the descending and sigmoid colon. Colonoscopy and histopathological findings were compatible with allergic colitis. After a diet change the 13 infants recovered and their oral challenge tests were positive. Doppler US may be very useful in diagnosing secondary colitis, such as CMA, and to exclude several other abdominal diseases that can emulate this disease. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Falkowski, Aleksander; Wilk, Grazyna; Mokrzyński, Stanisław; Dul, Przemysław; Toloczko-Grabarek, Aleksandra; Huzarski, Tomasz; Kowalczyk, Robert
2004-06-01
The aim of the study was not only to establish the applicability of color Doppler ultrasound of the neck vessels in patients with tumors of the oral cavity and the neck region but also to check whether the coexistence of sclerotic changes in the carotid arteries is essential in determination of the sequence of surgical procedure. Color Doppler ultrasound was performed on 110 patients, aged 15 -71 years with tumors of the oral cavity and the neck. The localization, size, echogenicity, as well as the tumor relationship to the surrounding structures and big vessels of the neck region was analyzed. Compression of the veins was observed in 27 cases, and of the arteries only in 20 cases. Infiltration of the jugular vein was observed in 8 patients, whereas infiltration of the carotid artery were seen only in 6 patients. Severe internal carotid artery stenosis, due to arteriosclerosis, was observed in 10 patients. Three persons were suggested to be operated on, first due to carotid artery stenosis, later on, due to the oral cavity tumor. It was found that color Doppler ultrasound is useful in deciding upon the method of treatment, while the examination of the neck vessels is helpful in establishing the sequence of surgical procedures in patients with tumors and coexisting arteriosclerosis.
An Eye-Tracking Study of How Color Coding Affects Multimedia Learning
ERIC Educational Resources Information Center
Ozcelik, Erol; Karakus, Turkan; Kursun, Engin; Cagiltay, Kursat
2009-01-01
Color coding has been proposed to promote more effective learning. However, insufficient evidence currently exists to show how color coding leads to better learning. The goal of this study was to investigate the underlying cause of the color coding effect by utilizing eye movement data. Fifty-two participants studied either a color-coded or…
Software For Clear-Air Doppler-Radar Display
NASA Technical Reports Server (NTRS)
Johnston, Bruce W.
1990-01-01
System of software developed to present plan-position-indicator scans of clear-air Doppler radar station on color graphical cathode-ray-tube display. Designed to incorporate latest accepted standards for equipment, computer programs, and meteorological data bases. Includes use of Ada programming language, of "Graphical-Kernel-System-like" graphics interface, and of Common Doppler Radar Exchange Format. Features include portability and maintainability. Use of Ada software packages produced number of software modules reused on other related projects.
A new Doppler-echo method to quantify regurgitant volume.
Wang, S S; Rubenstein, J J; Goldman, M; Sidd, J J
1992-01-01
An in vitro technique using color flow imaging and continuous wave Doppler was developed to measure the initial regurgitant flow jet diameter and velocity integral to yield the parameters for a volume calculation. Jets were produced by volume-controlled injection through tubes of various diameters (1.3, 1.9, 2.8, and 3.5 mm) to deliver volumes from 1 to 7 ml over 100 to 300 msec at pressures from 40 to 200 mm Hg. One hundred forty-five samples were obtained. Flow jet diameter consistently overestimated tube diameter by 2 mm when injected volume was 1.5 to 7 ml and by 1.5 mm when injected volume was less than 1.5 ml. This offset was stable with various transducers (2.5, 3.5, 5.0 MHz) at normal gain setting (just under noise). Therefore, corrected flow jet diameter (FJD) = FJD - 2 mm, and Doppler volume = corrected flow jet area x velocity integral. A range of injectates from 1.1 to 7 ml generated Doppler volume of 1.0 to 8.2 ml. The relation between Doppler volume (DV) and injected volume (IV) was DV = 1.079 IV - 0.22, r2 = 0.945, p less than 0.01. This relation was not altered by tube diameter. Thus a method combining color flow imaging and continuous wave Doppler provides a reliable and accurate measure of in vitro flow volume.
Lim, Gye-Yeon; Im, Soo Ah; Jung, Won Sang; Lee, Jae Mun; Lee, Ah Won
2005-09-01
The aim of this prospective study was to evaluate the diagnostic value of power Doppler ultrasonography (PDUS) and contrast-enhanced PDUS (CEPDUS) in the depiction and characterization of experimentally induced arthritis in the rabbit. Thirty rabbits were divided into three groups consisting of one control group (saline injection group) and two experimental groups: a suppurative arthritis group and a chemically induced synovitis group. The same amount (1 ml) of each agent was directly injected into the right hip joint. Serial color Doppler ultrasound (CDUS), PDUS, and CEPDUS images were obtained before and after injection. We observed that all of the infected knees in the suppurative arthritis group with Staphylococcus aureus demonstrated an increased signal on PDUS after inoculation. A minimal power Doppler signal was presented in the chemically induced synovitis group with talc injection, but none of the control knees demonstrated any increased signals. CEPDUS was the most sensitive imaging modality for evaluating the increase of blood flows in suppurative arthritis and was subsequently followed by PDUS and CDUS. The increased signals obtained with PDUS represent increased local blood flows; therefore, this technique can be used for evaluating the degree of inflammation. Furthermore, using the contrast agent enhances the sensitivity of PDUS, and it can even be useful for differentiating borderline cases. Copyright 2005 Wiley Periodicals, Inc
[Color Doppler ultrasonography--a new imaging procedure in maxillofacial surgery].
Reinert, S; Lentrodt, J
1991-01-01
Colour Doppler ultrasonography shows blood flow in real time and colour by combining the features of real time B mode ultrasound and Doppler. At each point in the image the returning signal is interrogated for both amplitude and frequency information. The resulting image shows all non-moving structures in shades of gray and moving structures in shades of red or blue depending on direction and velocity. The technique of colour Doppler ultrasonography and our experiences in 63 examinations are described. The clinical application of this new simple non-invasive method in maxillo-facial surgery is discussed.
Spatial transform coding of color images.
NASA Technical Reports Server (NTRS)
Pratt, W. K.
1971-01-01
The application of the transform-coding concept to the coding of color images represented by three primary color planes of data is discussed. The principles of spatial transform coding are reviewed and the merits of various methods of color-image representation are examined. A performance analysis is presented for the color-image transform-coding system. Results of a computer simulation of the coding system are also given. It is shown that, by transform coding, the chrominance content of a color image can be coded with an average of 1.0 bits per element or less without serious degradation. If luminance coding is also employed, the average rate reduces to about 2.0 bits per element or less.
ERIC Educational Resources Information Center
School Science Review, 1983
1983-01-01
Describes computer measurement of capacitor charge decay, change of fringe width with color, computer simulation of color mixing, Doppler effect/carrier waves, gravitational waves, microwave apparatus, computer simulation of Brownian motion, search coils and problems with the teaching of the relationships of velocity, frequency, and wavelength in…
Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D. Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin
2007-01-01
Background We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Methods Dynamic compliance (Cdyn) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. Cdyn was calculated as: [(Ds − Dd)/(Dd × Ps)] × 104; where Ds = systolic diameter, Dd = diastolic diameter, and Ps = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. Cdyn was also measured in an additional 13 patients undergoing reactivity studies. Results Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, Cdyn calculated by CMM DTI agreed with Cdyn calculated using invasive techniques (23.4 ± 16.8 vs 29.1 ± 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower Cdyn values than control subjects (P < .01). Cdyn values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress–strain behavior of these arteries. Reactivity in Cdyn agreed with reactivity measured using impedance techniques. Conclusion The Cdyn method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension. PMID:16581479
Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin
2006-04-01
We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Dynamic compliance (C(dyn)) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C(dyn) was calculated as: [(D(s) - D(d))/(D(d) x P(s))] x 10(4); where D(s) = systolic diameter, D(d) = diastolic diameter, and P(s) = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. C(dyn) was also measured in an additional 13 patients undergoing reactivity studies. Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C(dyn) calculated by CMM DTI agreed with C(dyn) calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C(dyn) values than control subjects (P < .01). C(dyn) values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C(dyn) agreed with reactivity measured using impedance techniques. The C(dyn) method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.
[Vascular complications following kidney transplant: the role of color-Doppler imaging].
Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale
2012-01-01
The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.
Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel
2012-01-01
To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.
Zuhur, Sayid Shafi; Özel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Çil, Esra; Altuntas, Yüksel
2012-01-01
OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age- and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. PMID:22358236
Thaden, Jeremy J; Tsang, Michael Y; Ayoub, Chadi; Padang, Ratnasari; Nkomo, Vuyisile T; Tucker, Stephen F; Cassidy, Cynthia S; Bremer, Merri; Kane, Garvan C; Pellikka, Patricia A
2017-08-01
It is presumed that echocardiographic laboratory accreditation leads to improved quality, but there are few data. We sought to compare the quality of echocardiographic examinations performed at accredited versus nonaccredited laboratories for the evaluation of valvular heart disease. We enrolled 335 consecutive valvular heart disease subjects who underwent echocardiography at our institution and an external accredited or nonaccredited institution within 6 months. Completeness and quality of echocardiographic reports and images were assessed by investigators blinded to the external laboratory accreditation status and echocardiographic results. Compared with nonaccredited laboratories, accredited sites more frequently reported patient sex (94% versus 78%; P <0.001), height and weight (96% versus 63%; P <0.001), blood pressure (86% versus 39%; P <0.001), left ventricular size (96% versus 83%; P <0.001), right ventricular size (94% versus 80%; P =0.001), and right ventricular function (87% versus 73%; P =0.006). Accredited laboratories had higher rates of complete and diagnostic color (58% versus 35%; P =0.002) and spectral Doppler imaging (45% versus 21%; P <0.0001). Concordance between external and internal grading of external studies was improved when diagnostic quantification was performed (85% versus 69%; P =0.003), and in patients with mitral regurgitation, reproducibility was improved with higher quality color Doppler imaging. Accredited echocardiographic laboratories had more complete reporting and better image quality, while echocardiographic quantification and color Doppler image quality were associated with improved concordance in grading valvular heart disease. Future quality improvement initiatives should highlight the importance of high-quality color Doppler imaging and echocardiographic quantification to improve the accuracy, reproducibility, and quality of echocardiographic studies for valvular heart disease. © 2017 American Heart Association, Inc.
[Unexpected cutaneous purpura in an infant].
Luo, Yang-Yang; Wei, Zhu; Zeng, Ying-Hong; Zhou, Bin; Tang, Jian-Ping
2016-11-01
A two-month-old boy visited the hospital due to unexpected cutaneous purpura and thrombocytopenia for 2 days. The physical examination revealed a purple mass on the back. The soft tissue color Doppler ultrasound showed rich blood signals in the tissue, and the results of bone marrow puncture indicated an increased number of megakaryocytes. After the treatment with hormone and gamma globulin, the platelet count rapidly increased and maintained at a normal level. Meanwhile, the boy was given oral administration of propranolol. He was followed up for 4 months and the volume of the mass on the back was reduced significantly. He had a definite diagnosis of hemangioma and immune thrombocytopenia. As for the patients with hemangioma complicated by thrombocytopenia, knowledge of Kasabach-Merritt syndrome should be enhanced and there should be a clarification of the association between thrombocytopenia and hemangioma. There should also be an alertness for thrombocytopenia of other causes.
2005-01-01
The results of preoperative preparation were analysed in 59 patients with prostatic benign hyperplasia (PBH) subjected to TUR. Treatment outcomes were assessed by transrectal ultrasound (color Doppler mapping) in two groups of patients. Group 1 received combined therapy including transrectal laser radiation of the prostate, group 2--transrectal magnetotherapy. The analysis showed that laser radiation reduced insignificantly the size of the prostate and adenomatous node, improved microcirculation and circulation in the prostate. This resulted in relief of inflammation and reduction of the number of postoperative inflammatory complications. Transrectal magnetotherapy has a positive effect on vascularization and hemodynamics of the prostate, local immunity, contamination of the tissues with pathogenic flora.
2015-01-01
Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents. PMID:25754367
Propofol Induction's Effect on Cardiac Function
2015-03-31
This Study Was Focused to Evaluate Feasibility of Doppler Tissue Monitoring During the Induction Anesthesia,; and Evaluate Routine Propofol Induction's Effect on Myocardial Tissue Motion, Using Non-invasive Doppler Tissue and 2D Speckle Tracking Imaging.; This is the First Study, to Our Knowledge, Which Has Evaluated the Possible Impact of Propofol Induction on LV Function.
Monnet, Eric; Pelsue, Davyd; MacPhail, Catriona
2006-02-01
To validate laser doppler flowmetry (LDF) for measurement of blood flow in the stomach wall of dogs with gastric dilatation-volvulus (GDV). Six purpose-bred dogs and 24 dogs with naturally occurring GDV. Experimental and clinical. Capillary blood flow in the body of the stomach and pyloric antrum was measured with LDF (tissue perfusion unit (TPU) before and after induction of portal hypertension (PH) and after PH plus gastric ischemia (GI; PH + GI) and compared with flow measured by colored microsphere technique. Capillary flow was measured by LDF in the stomach wall of dogs with GDV. PH and PH+GI induced a significant reduction in blood flow in the body of the stomach (P = .019). A significant positive correlation was present between percent changes in capillary blood flow measured by LDF and colored microspheres after induction of PH + GI in the body of the stomach (r = 0.94, P = .014) and in the pyloric antrum (r = 0.95, P = .049). Capillary blood flow measured in the body of the stomach of 6 dogs that required partial gastrectomy (5.00+/-3.30 TPU) was significantly lower than in dogs that did not (28.00+/-14.40 TPU, P = .013). LDF can detect variations in blood flow in the stomach wall of dogs. LDF may have application for evaluation of stomach wall viability during surgery in dogs with GDV.
Echocardiographic assessment of left ventricular diastolic function.
Pirat, Bahar; Zoghbi, William A
2007-09-01
Assessment of diastolic function and left ventricular filling pressures in the setting of both normal and reduced systolic function is of major importance particularly in patients with dyspnea. Since multiple echocardiography parameters are used to assess diastolic function each with some limitations, a comprehensive approach should be applied. Transmitral Doppler flow should be evaluated in combination with newer, less load dependent Doppler techniques. Tissue Doppler imaging provides accurate, well validated data regarding diastolic properties and filling pressures of the left ventricle. Tissue Doppler imaging should be the part of a routine echocardiography study due to its ease of use and high reproducibility. Pulmonary vein Doppler and flow propagation velocity should be incorporated into the evaluation when needed.
Do Doppler color flow algorithms for mapping disturbed flow make sense?
Gardin, J M; Lobodzinski, S M
1990-01-01
It has been suggested that a major advantage of Doppler color flow mapping is its ability to visualize areas of disturbed ("turbulent") flow, for example, in valvular stenosis or regurgitation and in shunts. To investigate how various color flow mapping instruments display disturbed flow information, color image processing was used to evaluate the most common velocity-variance color encoding algorithms of seven commercially available ultrasound machines. In six of seven machines, green was reportedly added by the variance display algorithms to map areas of disturbed flow. The amount of green intensity added to each pixel along the red and blue portions of the velocity reference color bar was calculated for each machine. In this study, velocities displayed on the reference color bar ranged from +/- 46 to +/- 64 cm/sec, depending on the Nyquist limit. Of note, changing the Nyquist limits depicted on the color reference bars did not change the distribution of the intensities of red, blue, or green within the contour of the reference map, but merely assigned different velocities to the pixels. Most color flow mapping algorithms in our study added increasing intensities of green to increasing positive (red) or negative (blue) velocities along their color reference bars. Most of these machines also added increasing green to red and blue color intensities horizontally across their reference bars as a marker of increased variance (spectral broadening). However, at any given velocity, marked variations were noted between different color flow mapping instruments in the amount of green added to their color velocity reference bars.(ABSTRACT TRUNCATED AT 250 WORDS)
Minami, Yasunori; Kudo, Masatoshi
2009-12-31
The success rate of percutaneous radiofrequency (RF) ablation for hepatocellular carcinoma (HCC) depends on correct targeting via an imaging technique. However, RF electrode insertion is not completely accurate for residual HCC nodules because B-mode ultrasound (US), color Doppler, and power Doppler US findings cannot adequately differentiate between treated and viable residual tumor tissue. Electrode insertion is also difficult when we must identify the true HCC nodule among many large regenerated nodules in cirrhotic liver. Two breakthroughs in the field of US technology, harmonic imaging and the development of second-generation contrast agents, have recently been described and have demonstrated the potential to dramatically broaden the scope of US diagnosis of hepatic lesions. Contrast-enhanced harmonic US imaging with an intravenous contrast agent can evaluate small hypervascular HCC even when B-mode US cannot adequately characterize tumor. Therefore, contrast-enhanced harmonic US can facilitate RF ablation electrode placement in hypervascular HCC, which is poorly depicted by B-mode US. The use of contrast-enhanced harmonic US in ablation therapy for liver cancer is an efficient approach.
Dillman, Jonathan R; Dehkordy, Soudabeh Fazeli; Smith, Ethan A; DiPietro, Michael A; Sanchez, Ramon; DeMatos-Maillard, Vera; Adler, Jeremy; Zhang, Bin; Trout, Andrew T
2017-07-01
Little is known about changes in the imaging appearances of the bowel and mesentery over time in either pediatric or adult patients with newly diagnosed small bowel Crohn disease treated with anti-tumor necrosis factor-alpha (anti-TNF-α) therapy. To define how bowel ultrasound findings change over time and correlate with laboratory inflammatory markers in children who have been newly diagnosed with pediatric small bowel Crohn disease and treated with infliximab. We included 28 pediatric patients treated with infliximab for newly diagnosed ileal Crohn disease who underwent bowel sonography prior to medical therapy and at approximately 2 weeks, 1 month, 3 months and 6 months after treatment initiation; these patients also had laboratory testing at baseline, 1 month and 6 months. We used linear mixed models to compare mean results between visits and evaluate whether ultrasound measurements changed over time. We used Spearman rank correlation to assess bivariate relationships. Mean subject age was 15.3±2.2 years; 11 subjects were girls (39%). We observed decreases in mean length of disease involvement (12.0±5.4 vs. 9.1±5.3 cm, P=0.02), maximum bowel wall thickness (5.6±1.8 vs. 4.7±1.7 mm, P=0.02), bowel wall color Doppler signal (1.7±0.9 vs. 1.2±0.8, P=0.002) and mesenteric color Doppler signal (1.1±0.9 vs. 0.6±0.6, P=0.005) at approximately 2 weeks following the initiation of infliximab compared to baseline. All laboratory inflammatory markers decreased at 1 month (P-values<0.0001). There was strong correlation between bowel wall color Doppler signal and fecal calprotectin (ρ=0.710; P<0.0001). Linear mixed models confirmed that maximum bowel wall thickness (P=0.04), length of disease involvement (P=0.0002) and bowel wall color Doppler signal (P<0.0001) change over time in response to infliximab, when adjusted for age, sex, azathioprine therapy, scanning radiologist and baseline short pediatric Crohn's disease activity index score. The ultrasound appearance of the bowel changes as early as 2 weeks after the initiation of infliximab therapy. There is strong correlation between bowel wall color Doppler signal and fecal calprotectin.
[Current role of color Doppler ultrasound in acute renal failure].
Bertolotto, M; Quaia, E; Rimondini, A; Lubin, E; Pozzi Mucelli, R
2001-01-01
Acute Renal Failure (ARF) is characterized by a rapid decline of the glomerular filtration rate, due to hypotension (prerenal ARF), obstruction of the urinary tract (post-renal ARF) or renal parenchymal disease (renal ARF). The differential diagnosis among different causes of ARF is based on anamnesis, clinical symptoms and laboratory data. Usually ultrasound (US) is the only imaging examination performed in these patients, because it is safe and readily available. In patients with ARF gray scale US is usually performed to rule out obstruction since it is highly sensitive to recognize hydronephrosis. Patients with renal ARF have no specific changes in renal morphology. The size of the kidneys is usually normal or increased, with smooth margins. Detection of small kidneys suggests underlying chronic renal pathology and worse prognosis. Echogenicity and parenchymal thickness are usually normal, but in some cases there are hyperechogenic kidneys, increased parenchymal thickness and increased cortico-medullary differentiation. Evaluation of renal vasculature with pulsed Doppler US is useful in the differential diagnosis between prerenal ARF and acute tubular necrosis (ATN), and in the diagnosis of renal obstruction. Latest generation US apparatus allow color Doppler and power Doppler evaluation of renal vasculature up to the interlobular vessels. A significant, but non specific, reduction in renal perfusion is usually appreciable in the patients with ARF. There are renal pathologic conditions presenting with ARF in which color Doppler US provides more specific morphologic and functional information. In particular, color Doppler US often provides direct or indirect signs which can lead to the right diagnosis in old patients with chronic renal insufficiency complicated with ARF, in patients with acute pyelonephritis, hepatic disease, vasculitis, thrombotic microangiopathies, and in patients with acute thrombosis of the renal artery and vein. Contrast enhanced US is another useful diagnostic tool in patients with ARF which has been recently introduced in clinical practice. Microbubble administration may reduce technical failure in the evaluation of the renal artery. Moreover, perfusion defects due to stenosis or thrombosis of the renal segmentary vessels are better recognized. New diagnostic possibilities of enhanced US include evaluation of both cortical and medullar vessels, and functional evaluation of renal perfusion. Measuring the transit time of the microbubbles is useful for the diagnosis of renal artery stenosis and, in transplanted kidneys, for differential diagnosis between ATN and acute rejection.
High-Resolution Tissue Doppler Imaging of the Zebrafish Heart During Its Regeneration
Su, Ta-Han; Shih, Cho-Chiang
2015-01-01
Abstract The human heart cannot regenerate after injury, whereas the adult zebrafish can fully regenerate its heart even after 20% of the ventricle is amputated. Many studies have begun to reveal the cellular and molecular mechanisms underlying this regenerative process, which have exciting implications for human cardiac diseases. However, the dynamic functions of the zebrafish heart during regeneration are not yet understood. This study established a high-resolution echocardiography for tissue Doppler imaging (TDI) of the zebrafish heart to explore the cardiac functions during different regeneration phases. Experiments were performed on AB-line adult zebrafish (n=40) in which 15% of the ventricle was surgically removed. An 80-MHz ultrasound TDI based on color M-mode imaging technology was employed. The cardiac flow velocities and patterns from both the ventricular chamber and myocardium were measured at different regeneration phases relative to the day of amputation. The peak velocities of early diastolic inflow, early diastolic myocardial motion, late diastolic myocardial motion, early diastolic deceleration slope, and heart rate were increased at 3 days after the myocardium amputation, but these parameters gradually returned to close to their baseline values for the normal heart at 7 days after amputation. The peak velocities of late diastolic inflow, ventricular systolic outflow, and systolic myocardial motion did not significantly differ during the heart regeneration. PMID:25517185
Ozaki, T; Hata, K; Xie, H; Takahashi, K; Miyazaki, K
2002-12-01
To investigate the relationship between color Doppler indices of dominant follicular blood flow and clinical factors in in vitro fertilization-embryo transfer cycles. This was a prospective study involving 26 patients completing a total of 33 in vitro fertilization cycles. Dominant follicular blood flow indices, peak systolic velocities, the resistance index and the pulsatility index were evaluated using transvaginal color Doppler. The indices were compared to the clinical outcomes of in vitro fertilization-embryo transfer. There was a significant correlation between dominant follicular peak systolic velocities and the number of oocytes retrieved, as well as the number of mature oocytes obtained. There was no significant correlation between dominant follicular resistance index or pulsatility index and the number of follicles > 10 mm in diameter, the number of oocytes retrieved or the number of mature oocytes. There were no significant differences between dominant follicular peak systolic velocities, resistance index or pulsatility index, and fertilization rate or the ratio of good quality embryos. However, significant differences were found between the number of oocytes retrieved, as well as the number of mature oocytes for those patients in which the peak systolic velocity was below 25 cm/s. Doppler assessment of dominant follicle blood flow alone is useful for predicting the number of retrievable oocytes. However, morphological quality of the embryo produced or the pregnancy rate cannot be predicted by this method.
Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D
2012-10-01
Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.
MacLea, H B; Boon, J A; Bright, J M
2013-01-01
Hypertrophic cardiomyopathy (HCM) is heterogeneous in both people and cats, with variability in the distribution of hypertrophy, hemodynamic characteristics, and Doppler echocardiographic findings. To document the Doppler echocardiographic characteristics of midventricular obstruction in some cats with HCM. Eight cats with hypertrophic cardiomyopathy. Retrospective case series. The medical records of cats presenting to the cardiology service at Colorado State University between February 2009 and January 2012 were reviewed. All cats had a physical examination; Doppler systolic blood pressure measurement; and transthoracic two-dimensional (2D), M-mode, and Doppler echocardiography were performed. A more thorough evaluation of the echocardiographic images and measurements was performed. Cats included in this study had echocardiograms of adequate quality to confirm the diagnosis of midventricular obstruction by documentation of left midventricular concentric hypertrophy; a midventricular turbulent Doppler color flow pattern; and high velocity, late-peaking flow at the area of turbulence. Cats with evidence of systemic hypertension defined as a systolic Doppler blood pressure of greater than 170 mmHg were excluded. All 8 cats had left ventricular hypertrophy at the level of the papillary muscles; left, midventricular hypertrophy; and in 4/8 cats there was apical hypertrophy or basilar hypertrophy of the interventricular septum. Color flow Doppler revealed turbulent flow in 8/8 cats and spectral Doppler (continuous and pulsed wave) revealed increased flow velocities and late-peaking flow profiles at the level of the left midventricle. Two of 8 cats had a bifid midventricular flow profile in which there was a midsystolic decline in left ventricular velocities with elevated velocities extending into early diastole. The peak left ventricular outflow velocity in all 8 cats was normal. A variant of HCM characterized by hypertrophy at the level of the papillary muscles with midventricular obstruction is present in some cats. Recognition of this variant of feline HCM allows identification of HCM in cats with murmurs where the more classic features of HCM are not present. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Ben-Simhon, Zohar; Judeinstein, Sylvie; Trainin, Taly; Harel-Beja, Rotem; Bar-Ya'akov, Irit; Borochov-Neori, Hamutal; Holland, Doron
2015-01-01
Color is an important determinant of pomegranate fruit quality and commercial value. To understand the genetic factors controlling color in pomegranate, chemical, molecular and genetic characterization of a "white" pomegranate was performed. This unique accession is lacking the typical pomegranate color rendered by anthocyanins in all tissues of the plant, including flowers, fruit (skin and arils) and leaves. Steady-state gene-expression analysis indicated that none of the analyzed "white" pomegranate tissues are able to synthesize mRNA corresponding to the PgLDOX gene (leucoanthocyanidin dioxygenase, also called ANS, anthocyanidin synthase), which is one of the central structural genes in the anthocyanin-biosynthesis pathway. HPLC analysis revealed that none of the "white" pomegranate tissues accumulate anthocyanins, whereas other flavonoids, corresponding to biochemical reactions upstream of LDOX, were present. Molecular analysis of the "white" pomegranate revealed the presence of an insertion and an SNP within the coding region of PgLDOX. It was found that the SNP does not change amino acid sequence and is not fully linked with the "white" phenotype in all pomegranate accessions from the collection. On the other hand, genotyping of pomegranate accessions from the collection and segregating populations for the "white" phenotype demonstrated its complete linkage with the insertion, inherited as a recessive single-gene trait. Taken together, the results indicate that the insertion in PgLDOX is responsible for the "white" anthocyanin-less phenotype. These data provide the first direct molecular, genetic and chemical evidence for the effect of a natural modification in the LDOX gene on color accumulation in a fruit-bearing woody perennial deciduous tree. This modification can be further utilized to elucidate the physiological role of anthocyanins in protecting the tree organs from harmful environmental conditions, such as temperature and UV radiation.
Ben-Simhon, Zohar; Judeinstein, Sylvie; Trainin, Taly; Harel-Beja, Rotem; Bar-Ya'akov, Irit; Borochov-Neori, Hamutal; Holland, Doron
2015-01-01
Color is an important determinant of pomegranate fruit quality and commercial value. To understand the genetic factors controlling color in pomegranate, chemical, molecular and genetic characterization of a "white" pomegranate was performed. This unique accession is lacking the typical pomegranate color rendered by anthocyanins in all tissues of the plant, including flowers, fruit (skin and arils) and leaves. Steady-state gene-expression analysis indicated that none of the analyzed "white" pomegranate tissues are able to synthesize mRNA corresponding to the PgLDOX gene (leucoanthocyanidin dioxygenase, also called ANS, anthocyanidin synthase), which is one of the central structural genes in the anthocyanin-biosynthesis pathway. HPLC analysis revealed that none of the "white" pomegranate tissues accumulate anthocyanins, whereas other flavonoids, corresponding to biochemical reactions upstream of LDOX, were present. Molecular analysis of the "white" pomegranate revealed the presence of an insertion and an SNP within the coding region of PgLDOX. It was found that the SNP does not change amino acid sequence and is not fully linked with the "white" phenotype in all pomegranate accessions from the collection. On the other hand, genotyping of pomegranate accessions from the collection and segregating populations for the "white" phenotype demonstrated its complete linkage with the insertion, inherited as a recessive single-gene trait. Taken together, the results indicate that the insertion in PgLDOX is responsible for the "white" anthocyanin-less phenotype. These data provide the first direct molecular, genetic and chemical evidence for the effect of a natural modification in the LDOX gene on color accumulation in a fruit-bearing woody perennial deciduous tree. This modification can be further utilized to elucidate the physiological role of anthocyanins in protecting the tree organs from harmful environmental conditions, such as temperature and UV radiation. PMID:26581077
Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw
2009-03-01
To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed <50%, and >50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing
Chen, Ming; Luo, Huai; Miyamoto, Takashi; Atar, Shaul; Kobal, Sergio; Rahban, Masoud; Brasch, Andrea V; Makkar, Rajendra; Neuman, Yoram; Naqvi, Tasneem Z; Tolstrup, Kirsten; Siegel, Robert J
2003-09-01
We assessed aortic regurgitation (AR) severity by utilizing multiple echo-Doppler variables in comparison with AR severity by aortic root angiography. Patients were divided into 3 groups: mild, moderate, and severe. An AR index (ARI) was developed, comprising 5 echocardiographic parameters: ratio of color AR jet height to left ventricular outlet flow diameter, AR signal density from continuous-wave Doppler, pressure half-time, left ventricular end-diastolic diameter, and aortic root diameter. There was a strong correlation between AR severity by angiography and the calculated echo-Doppler ARI (r = 0.84, p = 0.0001). As validated by aortic angiography, the ARI is an accurate reflection of AR severity.
NASA Astrophysics Data System (ADS)
Yang, Victor X. D.; Gordon, Maggie L.; Tang, Shou-Jiang; Marcon, Norman E.; Gardiner, Geoffrey; Qi, Bing; Bisland, Stuart; Seng-Yue, Emily; Lo, Stewart; Pekar, Julius; Wilson, Brian C.; Vitkin, I. Alex
2003-09-01
We previously described a fiber based Doppler optical coherence tomography system [1] capable of imaging embryo cardiac blood flow at 4~16 frames per second with wide velocity dynamic range [2]. Coupling this system to a linear scanning fiber optical catheter design that minimizes friction and vibrations, we report here the initial results of in vivo endoscopic Doppler optical coherence tomography (EDOCT) imaging in normal rat and human esophagus. Microvascular flow in blood vessels less than 100 µm diameter was detected using a combination of color-Doppler and velocity variance imaging modes, during clinical endoscopy using a mobile EDOCT system.
Araujo, Reno R; Ginther, O J
2009-01-01
To assess the vascular effects of detomidine and xylazine in pony mares and heifers, respectively, as determined in a major artery and by extent of vascular perfusion of reproductive organs. 10 pony mares and 10 Holstein heifers. Pony mares were assigned to receive physiologic saline (0.9% NaCl) solution (n = 5) or detomidine (3.0 mg/mare, IV; 5). Heifers were assigned to receive saline solution (5) or xylazine (14 mg/heifer, IM; 5). Color Doppler ultrasonographic examinations were performed immediately before and 10 minutes after administration of saline solution or sedative. In spectral Doppler mode, a spectral graph of blood flow velocities during a cardiac cycle was obtained at the internal iliac artery and at the ovarian pedicle. In color-flow mode, color signals of blood flow in vessels of the corpus luteum and endometrium were assessed. Systemic effects of sedation in the 2 species were evident as a decrease in heart rate; increase in duration of systole, diastole, or both; decrease in volume of blood flow; and decrease in velocity of blood flow within the internal iliac artery. However, an effect of sedatives on local vascular perfusion in the ovaries and endometrium was not detected. Sedation with detomidine in pony mares and xylazine in heifers did not affect vascular perfusion in reproductive organs. These sedatives can be used in experimental and clinical color Doppler evaluations of vascular perfusion of the corpus luteum and endometrium.
Tsang, Hin-Fung; Xue, Vivian Weiwen; Koh, Su-Pin; Chiu, Ya-Ming; Ng, Lawrence Po-Wah; Wong, Sze-Chuen Cesar
2017-01-01
Formalin-fixed, paraffin-embedded (FFPE) tissue sample is a gold mine of resources for molecular diagnosis and retrospective clinical studies. Although molecular technologies have expanded the range of mutations identified in FFPE samples, the applications of existing technologies are limited by the low nucleic acids yield and poor extraction quality. As a result, the routine clinical applications of molecular diagnosis using FFPE samples has been associated with many practical challenges. NanoString technologies utilize a novel digital color-coded barcode technology based on direct multiplexed measurement of gene expression and offer high levels of precision and sensitivity. Each color-coded barcode is attached to a single target-specific probe corresponding to a single gene which can be individually counted without amplification. Therefore, NanoString is especially useful for measuring gene expression in degraded clinical specimens. Areas covered: This article describes the applications of NanoString technologies in molecular diagnostics and challenges associated with its applications and the future development. Expert commentary: Although NanoString technology is still in the early stages of clinical use, it is expected that NanoString-based cancer expression panels would play more important roles in the future in classifying cancer patients and in predicting the response to therapy for better personal therapeutic care.
Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli.
Moehring, Mark A; Spencer, Merrill P
2002-01-01
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm spacing was configured to display Doppler signal power, colored red and blue for directionality, in an M-mode format. The spectrogram from a user-selected depth was displayed simultaneously. This system was then explored on healthy subjects and patients presenting with varying cerebrovascular pathology. PMD facilitated window location and alignment of the US beam to view blood flow from multiple vessels simultaneously, without sound or spectral clues. Microemboli appeared as characteristic sloping high-power tracks in the PMD image. Power M-mode Doppler is a new paradigm facilitating vessel location, diagnosis, monitoring and microembolus detection.
Effect of Color-Coded Notation on Music Achievement of Elementary Instrumental Students.
ERIC Educational Resources Information Center
Rogers, George L.
1991-01-01
Presents results of a study of color-coded notation to teach music reading to instrumental students. Finds no clear evidence that color-coded notation enhances achievement on performing by memory, sight-reading, or note naming. Suggests that some students depended on the color-coding and were unable to read uncolored notation well. (DK)
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 5 2013-07-01 2013-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 5 2014-07-01 2014-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 5 2012-07-01 2012-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 5 2010-07-01 2010-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be... basic color for designating caution and for marking physical hazards such as: Striking against...
Signal processing of aircraft flyover noise
NASA Technical Reports Server (NTRS)
Kelly, Jeffrey J.
1991-01-01
A detailed analysis of signal processing concerns for measuring aircraft flyover noise is presented. Development of a de-Dopplerization scheme for both corrected time history and spectral data is discussed along with an analysis of motion effects on measured spectra. A computer code was written to implement the de-Dopplerization scheme. Input to the code is the aircraft position data and the pressure time histories. To facilitate ensemble averaging, a uniform level flyover is considered but the code can accept more general flight profiles. The effects of spectral smearing and its removal is discussed. Using data acquired from XV-15 tilt rotor flyover test comparisons are made showing the measured and corrected spectra. Frequency shifts are accurately accounted for by the method. It is shown that correcting for spherical spreading, Doppler amplitude, and frequency can give some idea about source directivity. The analysis indicated that smearing increases with frequency and is more severe on approach than recession.
Hoffman, Robert M
2014-01-01
We have developed a transgenic green fluorescent protein (GFP) nude mouse with ubiquitous GFP expression. The GFP nude mouse was obtained by crossing nontransgenic nude mice with the transgenic C57/B6 mouse in which the β-actin promoter drives GFP expression in essentially all tissues. In the adult mice, many organs brightly expressed GFP, including the spleen, heart, lungs, spleen, pancreas, esophagus, stomach, and duodenum as well as the circulatory system. The liver expressed GFP at a lesser level. The red fluorescent protein (RFP) transgenic nude mouse was obtained by crossing non-transgenic nude mice with the transgenic C57/B6 mouse in which the beta-actin promoter drives RFP (DsRed2) expression in essentially all tissues. In the RFP nude mouse, the organs all brightly expressed RFP, including the heart, lungs, spleen, pancreas, esophagus, stomach, liver, duodenum, the male and female reproductive systems; brain and spinal cord; and the circulatory system, including the heart, and major arteries and veins. The skinned skeleton highly expressed RFP. The bone marrow and spleen cells were also RFP positive. The cyan fluorescent protein (CFP) nude mouse was developed by crossing nontransgenic nude mice with the transgenic CK/ECFP mouse in which the β-actin promoter drives expression of CFP in almost all tissues. In the CFP nude mice, the pancreas and reproductive organs displayed the strongest fluorescence signals of all internal organs, which vary in intensity. The GFP, RFP, and CFP nude mice when transplanted with cancer cells of another color are powerful models for color-coded imaging of the tumor microenvironment (TME) at the cellular level.
Chen, Tien-En; Kwon, Susan H; Enriquez-Sarano, Maurice; Wong, Benjamin F; Mankad, Sunil V
2013-10-01
Three-dimensional (3D) color Doppler echocardiography (CDE) provides directly measured vena contracta area (VCA). However, a large comprehensive 3D color Doppler echocardiographic study with sufficiently severe tricuspid regurgitation (TR) to verify its value in determining TR severity in comparison with conventional quantitative and semiquantitative two-dimensional (2D) parameters has not been previously conducted. The aim of this study was to examine the utility and feasibility of directly measured VCA by 3D transthoracic CDE, its correlation with 2D echocardiographic measurements of TR, and its ability to determine severe TR. Ninety-two patients with mild or greater TR prospectively underwent 2D and 3D transthoracic echocardiography. Two-dimensional evaluation of TR severity included the ratio of jet area to right atrial area, vena contracta width, and quantification of effective regurgitant orifice area using the flow convergence method. Full-volume breath-hold 3D color data sets of TR were obtained using a real-time 3D echocardiography system. VCA was directly measured by 3D-guided direct planimetry of the color jet. Subgroup analysis included the presence of a pacemaker, eccentricity of the TR jet, ellipticity of the orifice shape, underlying TR mechanism, and baseline rhythm. Three-dimensional VCA correlated well with effective regurgitant orifice area (r = 0.62, P < .0001), moderately with vena contracta width (r = 0.42, P < .0001), and weakly with jet area/right atrial area ratio. Subgroup analysis comparing 3D VCA with 2D effective regurgitant orifice area demonstrated excellent correlation for organic TR (r = 0.86, P < .0001), regular rhythm (r = 0.78, P < .0001), and circular orifice (r = 0.72, P < .0001) but poor correlation in atrial fibrillation rhythm (r = 0.23, P = .0033). Receiver operating characteristic curve analysis for 3D VCA demonstrated good accuracy for severe TR determination. Three-dimensional VCA measurement is feasible and obtainable in the majority of patients with mild or greater TR. Three-dimensional VCA measurement is also feasible in patients with atrial fibrillation but performed poorly even with <20% cycle length variation. Three-dimensional VCA has good cutoff accuracy in determining severe TR. This simple, straightforward 3D color Doppler measurement shows promise as an alternative for the quantification of TR. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh
2013-04-01
This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.
Lombardi, Roberta; Menchini, Laura; Corneli, Teresa; Magistrelli, Andrea; Accinni, Antonella; Monti, Lidia; Tomà, Paolo
2014-03-01
Wandering spleen is a rare condition in children that is often caused by loss or weakening of the splenic ligaments. Its clinical presentation is variable; 64% of children with wandering spleen have splenic torsion as a complication. To provide up-to-date information on the diagnosis, clinical management and diagnostic imaging approaches for wandering spleen in infants and children and to underline the importance of color Doppler US and CT in providing important information for patient management. We report a series of three children with wandering spleen treated at our children's hospital over the last 6 years. All three underwent clinical evaluation, color Doppler US and CT and were surgically treated. We also reviewed 40 articles that included 55 patients younger than 18 years reported in the Medline database from 2002 to 2012. We correlated pathological data with imaging findings. Color Doppler US, the first imaging modality in investigating abdominal symptoms in children with suspected wandering spleen, yielded a diagnostic sensitivity of 54.9%, whereas CT achieved about 71.7%. Radiologic evaluation has a major role in confirming the diagnosis of a suspected wandering spleen and avoiding potentially life-threatening complications requiring immediate surgery.
Yang, Guang; Raschke, Felix; Barrick, Thomas R; Howe, Franklyn A
2015-09-01
To investigate whether nonlinear dimensionality reduction improves unsupervised classification of (1) H MRS brain tumor data compared with a linear method. In vivo single-voxel (1) H magnetic resonance spectroscopy (55 patients) and (1) H magnetic resonance spectroscopy imaging (MRSI) (29 patients) data were acquired from histopathologically diagnosed gliomas. Data reduction using Laplacian eigenmaps (LE) or independent component analysis (ICA) was followed by k-means clustering or agglomerative hierarchical clustering (AHC) for unsupervised learning to assess tumor grade and for tissue type segmentation of MRSI data. An accuracy of 93% in classification of glioma grade II and grade IV, with 100% accuracy in distinguishing tumor and normal spectra, was obtained by LE with unsupervised clustering, but not with the combination of k-means and ICA. With (1) H MRSI data, LE provided a more linear distribution of data for cluster analysis and better cluster stability than ICA. LE combined with k-means or AHC provided 91% accuracy for classifying tumor grade and 100% accuracy for identifying normal tissue voxels. Color-coded visualization of normal brain, tumor core, and infiltration regions was achieved with LE combined with AHC. The LE method is promising for unsupervised clustering to separate brain and tumor tissue with automated color-coding for visualization of (1) H MRSI data after cluster analysis. © 2014 Wiley Periodicals, Inc.
Su, Haobo; Lou, Wensheng; Gu, Jianping
2015-10-06
To investigate the feasibility of parametric color coding of digital subtraction angiography (Syngo iFlow) for hemodynamics assessment in patients with critical limb ischemia in pre- and post-endovascular therapy. To explore the correlation between Syngo iFlow and the conventional techniques. from January 2013 to December 2014, Clinical data of 21 patients with TASC II type B and type C femoropopliteal arteriosclerotic occlusive disease who were treated by percutaneous transluminal angioplasty and/or primary stent implantation in Nanjing first hospital were analyzed retrospectively. Of these patients there were 10 males and 11 females with an average age of (72±6) years (range from 58-85 years). The treatment efficacy was assessed by the variation of a series of clinical symptoms indexes (such as pain score, cold sensation score and intermittent claudication score), ankle braehial index (ABI) and transcutaneous oxygen pressure (TcPO2). Angiography was performed with the same protocol before and after treatment and parametric color coding of digital subtraction angiography was created by Syngo iFlow software on a dedicated workstation. The time to peak (TTP) of artery and tissue perfusion selected at the same regions of foot and ankle were measured and analyzed to evaluate the improvement of microcirculation and hemodynamics of the ischemic limb. The correlations between Syngo iFlow and the traditional clinical evaluation methods were explored using the Spearman rank correlation test. All patients (21 limbs) underwent successful endovaseular therapy. The mean pain score, cold sensation score, intermittent claudication score, ABI and TcPO2 before treatment were (0.48±0.68), (2.71±0.72), (2.86±0.85), ABI (0.33±0.07), TcPO2 (26.83±3.41) mmHg. While 1 week after treatment all above indicators were (2.57±0.93), (0.33±0.48), (0.90±0.54), (0.69±0.11), TcPO2 (53.75±3.60) mmHg respectively. There were significant statistical differences between pre- and post-treatment (P<0.05). The pre- and post-operative TTP of artery and tissue perfusion were (14.07±1.77) vs (10.43±2.05) s, (18.75±2.72) vs (15.38±2.78) s. For assessment of hemodynamic changes during and after treatment, parametric color coding of digital subtraction angiography (Syngo iFlow) was assumed to show the limb blood flow and perfusion were improved and the differences were statistically significant. The Spearman rank correlation test showed the TTP of artery was positively correlated with ABI, TcPO2 (r=0.65, 0.73, P<0.05), the TTP of tissue perfusion was also positively correlated with ABI, TcPO2 (r=0.60, 0.60, P<0.05). Parametric color coding of digital subtraction angiography (Syngo iFlow) is a real-time, sensitive and quantitative tool that might provide additional support in the hemodynamics evaluation of endovascular treatment for patients with lower extremity peripheral arterial occlusion disease.
Pseudo color ghost coding imaging with pseudo thermal light
NASA Astrophysics Data System (ADS)
Duan, De-yang; Xia, Yun-jie
2018-04-01
We present a new pseudo color imaging scheme named pseudo color ghost coding imaging based on ghost imaging but with multiwavelength source modulated by a spatial light modulator. Compared with conventional pseudo color imaging where there is no nondegenerate wavelength spatial correlations resulting in extra monochromatic images, the degenerate wavelength and nondegenerate wavelength spatial correlations between the idle beam and signal beam can be obtained simultaneously. This scheme can obtain more colorful image with higher quality than that in conventional pseudo color coding techniques. More importantly, a significant advantage of the scheme compared to the conventional pseudo color coding imaging techniques is the image with different colors can be obtained without changing the light source and spatial filter.
Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications.
Taljanovic, Mihra S; Gimber, Lana H; Becker, Giles W; Latt, L Daniel; Klauser, Andrea S; Melville, David M; Gao, Liang; Witte, Russell S
2017-01-01
In the past 2 decades, sonoelastography has been progressively used as a tool to help evaluate soft-tissue elasticity and add to information obtained with conventional gray-scale and Doppler ultrasonographic techniques. Recently introduced on clinical scanners, shear-wave elastography (SWE) is considered to be more objective, quantitative, and reproducible than compression sonoelastography with increasing applications to the musculoskeletal system. SWE uses an acoustic radiation force pulse sequence to generate shear waves, which propagate perpendicular to the ultrasound beam, causing transient displacements. The distribution of shear-wave velocities at each pixel is directly related to the shear modulus, an absolute measure of the tissue's elastic properties. Shear-wave images are automatically coregistered with standard B-mode images to provide quantitative color elastograms with anatomic specificity. Shear waves propagate faster through stiffer contracted tissue, as well as along the long axis of tendon and muscle. SWE has a promising role in determining the severity of disease and treatment follow-up of various musculoskeletal tissues including tendons, muscles, nerves, and ligaments. This article describes the basic ultrasound physics of SWE and its applications in the evaluation of various traumatic and pathologic conditions of the musculoskeletal system. © RSNA, 2017.
NASA Astrophysics Data System (ADS)
Hallacoglu, Bertan; Matulewicz, Richard S.; Paltiel, Harriet J.; Padua, Horacio; Gargollo, Patricio; Cannon, Glenn; Alomari, Ahmad; Sassaroli, Angelo; Fantini, Sergio
2009-09-01
We present a quantitative near-IR spectroscopy study of the absolute values of oxygen saturation of hemoglobin before and after surgically induced testicular torsion in adult rabbits. Unilateral testicular torsions (0, 540, or 720 deg) on experimental testes and contralateral sham surgery on control testes are performed in four adult rabbits. A specially designed optical probe for measurements at multiple source-detector distances and a commercial frequency-domain tissue spectrometer are used to measure absolute values of testicular hemoglobin saturation. Our results show: (1) a consistent baseline absolute tissue hemoglobin saturation value of 78+/-5%, (2) a comparable tissue hemoglobin saturation of 77+/-6% after sham surgery, and (3) a significantly lower tissue hemoglobin saturation of 36+/-2% after 540- and 720-deg testicular torsion surgery. Our findings demonstrate the feasibility of performing frequency-domain, multidistance near-IR spectroscopy for absolute testicular oximetry in the assessment of testicular torsion. We conclude that near-IR spectroscopy has potential to serve as a clinical diagnostic and monitoring tool for the assessment of absolute testicular hemoglobin desaturation caused by torsion, with the possibility of serving as a complement to conventional color and spectral Doppler ultrasonography.
Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren; Christensen, Robin; Boesen, Lars; Hölmich, Per; Nielsen, Michael Bachmann; Koenig, Merete Juhl; Hartkopp, Andreas; Ellegaard, Karen; Bliddal, Henning; Langberg, Henning
2012-03-01
Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear. Intratendinous flow is present and associated with pain in badminton players, and intratendinous flow and pain increase during a badminton season. Cohort study (prognosis); Level of evidence, 2. Ninety-five semiprofessional badminton players were included in the study at a tournament at the start of the badminton season. All players were interviewed regarding pain. The anterior knee tendons and Achilles tendons were studied. Each tendon was scored using a quantitative grading system (grades 0-5) and a qualitative scoring system (color fraction) using color Doppler ultrasound. Eight months later, 86 of the players (91%) were retested by the same investigators during an equivalent badminton tournament (including 1032 tendon regions; 86 players with 4 tendons each with 3 regions), thus forming the study group. At the start of the season, 24 players (28%) experienced pain in 37 tendons (11%), and at the end of the season, 31 players (36%) experienced pain in 51 tendons (15%), which was a statistically significant increase (P = .0002). Abnormal flow was found in 230 tendon regions in 71 players (83%) at the start of the season compared with 78 tendon regions in 41 players (48%) at the follow-up. The decrease in abnormal flow was statistically significant (P < .0001). Of the 37 painful tendons at the start of the season, 25 had abnormal flow (68%). In contrast, 131 tendons (85%) with abnormal flow at the start of the season were pain free. At the end of the season, 18 of the 51 painful tendons (35%) had abnormal flow. Ninety-six of the 131 pain-free tendons (73%) with abnormal flow at the start of the season were normalized (no pain and normal flow) at the end of the season. It was not possible to verify any association between intratendinous flow and pain at the start of the season or at the follow-up (end of the season). Intratendinous flow at the start of the season could not predict symptomatic outcome at the end of the season. The decrease in Doppler flow during the season might suggest that intratendinous flow could be part of a physiological adaptive response to loading and that intratendinous flow as previously believed is not always a sign of pathological changes.
Braiding by Majorana tracking and long-range CNOT gates with color codes
NASA Astrophysics Data System (ADS)
Litinski, Daniel; von Oppen, Felix
2017-11-01
Color-code quantum computation seamlessly combines Majorana-based hardware with topological error correction. Specifically, as Clifford gates are transversal in two-dimensional color codes, they enable the use of the Majoranas' non-Abelian statistics for gate operations at the code level. Here, we discuss the implementation of color codes in arrays of Majorana nanowires that avoid branched networks such as T junctions, thereby simplifying their realization. We show that, in such implementations, non-Abelian statistics can be exploited without ever performing physical braiding operations. Physical braiding operations are replaced by Majorana tracking, an entirely software-based protocol which appropriately updates the Majoranas involved in the color-code stabilizer measurements. This approach minimizes the required hardware operations for single-qubit Clifford gates. For Clifford completeness, we combine color codes with surface codes, and use color-to-surface-code lattice surgery for long-range multitarget CNOT gates which have a time overhead that grows only logarithmically with the physical distance separating control and target qubits. With the addition of magic state distillation, our architecture describes a fault-tolerant universal quantum computer in systems such as networks of tetrons, hexons, or Majorana box qubits, but can also be applied to nontopological qubit platforms.
Bellamy, Justin L; Mundinger, Gerhard S; Flores, José M; Wimmers, Eric G; Yalanis, Georgia C; Rodriguez, Eduardo D; Sacks, Justin M
2015-03-01
Multiple perfusion assessment technologies exist to identify compromised microvascular free flaps. The effectiveness, operability, and cost of each technology vary. The authors investigated surgeon preference and clinical behavior with several perfusion assessment technologies. A questionnaire was sent to members of the American Society for Reconstructive Microsurgery concerning perceptions and frequency of use of several technologies in varied clinical situations. Demographic information was also collected. Adjusted odds ratios were calculated using multinomial logistic regression accounting for clustering of similar practices within institutions/regions. The questionnaire was completed by 157 of 389 participants (40.4 percent response rate). Handheld Doppler was the most commonly preferred free flap-monitoring technology (56.1 percent), followed by implantable Doppler (22.9 percent) and cutaneous tissue oximetry (16.6 percent). Surgeons were significantly more likely to opt for immediate take-back to the operating room when presented with a concerning tissue oximetry readout compared with a concerning handheld Doppler signal (OR, 2.82; p < 0.01), whereas other technologies did not significantly alter postoperative management more than simple handheld Doppler. Clinical decision making did not significantly differ by demographics, training, or practice setup. Although most surgeons still prefer to use standard handheld Doppler for free flap assessment, respondents were significantly more likely to opt for immediate return to the operating room for a concerning tissue oximetry reading than an abnormal Doppler signal. This suggests that tissue oximetry may have the greatest impact on clinical decision making in the postoperative period.
[Role of cardiac magnetic resonance in cardiac involvement of Fabry disease].
Serra, Viviana M; Barba, Miguel Angel; Torrá, Roser; Pérez De Isla, Leopoldo; López, Mónica; Calli, Andrea; Feltes, Gisela; Torras, Joan; Valverde, Victor; Zamorano, José L
2010-09-04
Fabry disease is a hereditary disorder. Clinical manifestations are multisystemic. The majority of the patients remain undiagnosed until late in life, when alterations could be irreversible. Early detection of cardiac symptoms is of major interest in Fabry's disease (FD) in order to gain access to enzyme replacement therapy. Echo-Doppler tissular imaging (TDI) has been used as a cardiologic early marker in FD. This study is intended to determine whether the cardiac magnetic resonance is as useful tool as TDI for the early detection of cardiac affectation in FD. Echocardiography, tissue Doppler and Cardio magnetic resonance was performed in 20 patients with confirmed Fabry Disease. Left ventricular hypertrophy was defined as septum and left ventricular posterior wall thickness ≥12 mm. An abnormal TDI velocity was defined as (Sa), (Ea) and/or (Aa) velocities <8 cm/s at either the septal or lateral corner. Late phase gadolinium-enhanced images sequences were obtained using magnetic resonance. Twenty patients included in the study were divided into three groups: 1. Those without left ventricular hypertrophy nor tissue Doppler impairment 2. Those without left ventricular hypertrophy and tissue Doppler impairment 3. Those with left ventricular hypertrophy and Tissue Doppler impairment. Late gadolinium enhancement was found in only one patient, who has already altered DTI and LVH. Tissue Doppler imaging (TDI) is the only diagnostic tool able to provide early detection of cardiac affectation in patients with FD. Magnetic resonance provides information of the disease severity in patients with LVH, but can not be used as an early marker of cardiac disease in patients with FD. However MRI could be of great value for diagnostic stratification. Copyright © 2009 Elsevier España, S.L. All rights reserved.
The Use of Color-Coded Genograms in Family Therapy.
ERIC Educational Resources Information Center
Lewis, Karen Gail
1989-01-01
Describes a variable color-coding system which has been added to the standard family genogram in which characteristics or issues associated with a particular presenting problem or for a particular family are arbitrarily assigned a color. Presents advantages of color-coding, followed by clinical examples. (Author/ABL)
Color coding of control room displays: the psychocartography of visual layering effects.
Van Laar, Darren; Deshe, Ofer
2007-06-01
To evaluate which of three color coding methods (monochrome, maximally discriminable, and visual layering) used to code four types of control room display format (bars, tables, trend, mimic) was superior in two classes of task (search, compare). It has recently been shown that color coding of visual layers, as used in cartography, may be used to color code any type of information display, but this has yet to be fully evaluated. Twenty-four people took part in a 2 (task) x 3 (coding method) x 4 (format) wholly repeated measures design. The dependent variables assessed were target location reaction time, error rates, workload, and subjective feedback. Overall, the visual layers coding method produced significantly faster reaction times than did the maximally discriminable and the monochrome methods for both the search and compare tasks. No significant difference in errors was observed between conditions for either task type. Significantly less perceived workload was experienced with the visual layers coding method, which was also rated more highly than the other coding methods on a 14-item visual display quality questionnaire. The visual layers coding method is superior to other color coding methods for control room displays when the method supports the user's task. The visual layers color coding method has wide applicability to the design of all complex information displays utilizing color coding, from the most maplike (e.g., air traffic control) to the most abstract (e.g., abstracted ecological display).
Zhao, Chong-Ke; Xu, Hui-Xiong; Lu, Feng; Sun, Li-Ping; He, Ya-Ping; Guo, Le-Hang; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen
2017-01-01
To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P < 0.05). The mean VRRs of all BTNs were 23.4%, 54.4% and 81.9% at the 1-, 3- and 6-month follow-up, respectively. All BTNs achieved therapeutic success in this series in that all had VRRs of >50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P < 0.05). The factors associated with initial ICA after RFA for BTNs were predominantly solid nodules, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with those with ICA.
Ultrasound Doppler method of remote elastometry
NASA Astrophysics Data System (ADS)
Timanin, E. M.; Eremin, E. V.; Belyaev, R. V.; Mansfel'd, A. D.
2015-03-01
The paper presents the theoretical relations constituting the basis of remote measurements of the shear elasticity of biological tissues using the ultrasound Doppler method. It also describes the hardware-software setup implementing this approach, as well as the results of experiments with these tools on a biological tissue phantom and on human liver in vivo.
[Effect of cupping on hemodynamic levels in the regional sucked tissues in patients with lumbago].
Tang, Xiao; Xiao, Xue-Hua; Zhang, Guo-Qing
2012-10-01
To observe hemodynamic changes in the local sucked tissue of lower back undergoing negative pressure after cupping in patients with lumbago. Twenty-two lumbago outpatients were recruited in the present study and 32 sucked tissues accepted measurements. The cupping was applied to the tenderpoint of the patients' lower back for 10 min by using a glass-mug (5 cm in diameter). Hemodynamic indexes [peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI)] of the sucked skin and subcutaneous tissues at the lower back were detected before and after cupping by using a color Doppler flow imaging. After cupping intervention at the lower back, the PSV [(14.2 +/- 1.8) cm/s] and EDV [(5.5 +/- 0.7) cm/s] levels were increased significantly in comparison with those [(5.9 +/- 0.9) and (1.9 +/- 0.3) cm/s] before cupping (P < 0.01), while RI was reduced evidently after cupping (0.61 +/- 0.05 vs 0.68 +/- 0.06, P < 0.01), suggesting an increase of the regional blood flow. Cupping therapy can increase the peak systolic velocity and end-diastolic velocity and lower vascular resistance of the subcutaneous arterioles in the regional tissue, which may contribute to its effect in relieving lumbago.
Abdelaziz, Omar; Attia, Hussein
2016-01-01
Living-donor liver transplantation has provided a solution to the severe lack of cadaver grafts for the replacement of liver afflicted with end-stage cirrhosis, fulminant disease, or inborn errors of metabolism. Vascular complications remain the most serious complications and a common cause for graft failure after hepatic transplantation. Doppler ultrasound remains the primary radiological imaging modality for the diagnosis of such complications. This article presents a brief review of intra- and post-operative living donor liver transplantation anatomy and a synopsis of the role of ultrasonography and color Doppler in evaluating the graft vascular haemodynamics both during surgery and post-operatively in accurately defining the early vascular complications. Intra-operative ultrasonography of the liver graft provides the surgeon with useful real-time diagnostic and staging information that may result in an alteration in the planned surgical approach and corrections of surgical complications during the procedure of vascular anastomoses. The relevant intra-operative anatomy and the spectrum of normal and abnormal findings are described. Ultrasonography and color Doppler also provides the clinicians and surgeons early post-operative potential developmental complications that may occur during hospital stay. Early detection and thus early problem solving can make the difference between graft survival and failure. PMID:27468207
NASA Technical Reports Server (NTRS)
Greenberg, N. L.; Castro, P. L.; Drinko, J.; Garcia, M. J.; Thomas, J. D.
2000-01-01
Color M-mode echocardiography has recently been utilized to describe diastolic flow propagation velocity (Vp) in the left ventricle. While increasing temporal resolution from 15 to 200 Hz, this M-mode technique requires the user to select a single scanline, potentially limiting quantification of Vp due to the complex three-dimensional inflow pattern. We previously performed computational fluid dynamics simulations to demonstrate the insignificance of the scanline orientation, however geometric complexity was limited. The purpose of this study was to utilize high frame-rate 2D color Doppler images to investigate the importance of scanline selection in patients for the quantification of Vp. 2D color Doppler images were digitally acquired at 50 frames/s in 6 subjects from the apical 4-chamber window (System 5, GE/Vingmed, Milwaukee, WI). Vp was determined for a set of scanlines positioned through 5 locations across the mitral annulus (from the anterior to posterior mitral annulus). An analysis of variance was performed to examine the differences in Vp as a function of scanline position. Vp was not effected by scanline position in sampled locations from the center of the mitral valve towards the posterior annulus. Although not statistically significant, there was a trend to slower propagation velocities on the anterior side of the valve (60.8 +/- 16.7 vs. 54.4 +/- 13.6 cm/s). This study clinically validates our previous numerical experiment showing that Vp is insensitive to small perturbations of the scanline through the mitral valve. However, further investigation is necessary to examine the impact of ventricular geometry in pathologies including dilated cardiomyopathy.
Lumsden, Sarah; Rosta, Gabor; Bismuth, Jean; Lumsden, Alan B.; Garami, Zsolt
2017-01-01
Dissection of the internal carotid artery (ICA) accounts for 5% to 25% of ischemic strokes in young adults. We report a case of spontaneous recanalization of a traumatic ICA dissection in which carotid duplex (CDU) and transcranial color-coded duplex ultrasound (TCCD) were used. A 47-year-old male presented with intermittent episodes of headache, blurry vision, anisocoria, and loss of taste sensation following a whiplash injury while body surfing. Magnetic resonance angiogram (MRA) of the neck revealed absent flow in the cavernous ICA and a clot at the skull base. Carotid duplex, used to further evaluate flow, demonstrated reverberating color Doppler and spectrum signal. A TCCD showed ICA occlusion and smaller-caliber intracranial ICA. The patient reported for follow-up after 1 month on anticoagulation therapy. Upon his return, CDU and TCCD were normal and the ICA showed normal color and spectrum signals. Computed tomography angiogram confirmed ultrasound findings of a dramatic improvement of ICA patency. Additionally, the patient reported that his headaches had resolved. Extracranial CDU and TCCD are useful for monitoring patient progress in cases of spontaneous recanalization following carotid artery dissection. These inexpensive and noninvasive imaging modalities proved to be critical in the initial and follow-up evaluations of the extracranial and intracranial vascular system, providing a strong alternative to expensive magnetic resonance imaging and invasive angiograms and offering more hemodynamic information than “static” MRA. PMID:29744017
NASA Astrophysics Data System (ADS)
Pohling, Christoph; Bocklitz, Thomas; Duarte, Alex S.; Emmanuello, Cinzia; Ishikawa, Mariana S.; Dietzeck, Benjamin; Buckup, Tiago; Uckermann, Ortrud; Schackert, Gabriele; Kirsch, Matthias; Schmitt, Michael; Popp, Jürgen; Motzkus, Marcus
2017-06-01
Multiplex coherent anti-Stokes Raman scattering (MCARS) microscopy was carried out to map a solid tumor in mouse brain tissue. The border between normal and tumor tissue was visualized using support vector machines (SVM) as a higher ranking type of data classification. Training data were collected separately in both tissue types, and the image contrast is based on class affiliation of the single spectra. Color coding in the image generated by SVM is then related to pathological information instead of single spectral intensities or spectral differences within the data set. The results show good agreement with the H&E stained reference and spontaneous Raman microscopy, proving the validity of the MCARS approach in combination with SVM.
Topological color codes on Union Jack lattices: a stable implementation of the whole Clifford group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katzgraber, Helmut G.; Theoretische Physik, ETH Zurich, CH-8093 Zurich; Bombin, H.
We study the error threshold of topological color codes on Union Jack lattices that allow for the full implementation of the whole Clifford group of quantum gates. After mapping the error-correction process onto a statistical mechanical random three-body Ising model on a Union Jack lattice, we compute its phase diagram in the temperature-disorder plane using Monte Carlo simulations. Surprisingly, topological color codes on Union Jack lattices have a similar error stability to color codes on triangular lattices, as well as to the Kitaev toric code. The enhanced computational capabilities of the topological color codes on Union Jack lattices with respectmore » to triangular lattices and the toric code combined with the inherent robustness of this implementation show good prospects for future stable quantum computer implementations.« less
Kim, Se Hyung; Lee, Jeong Min; Kim, Young Jun; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn
2008-10-01
The purpose of this study was to introduce a new high-definition flow (HDF) Doppler technique and to compare its performance with those of color Doppler ultrasonography (CDU) and power Doppler ultrasonography (PDU) for assessment of hepatic vasculature in native and transplanted livers. High-definition flow was invented as a high-resolution bidirectional PDU technique. We obtained CDU, PDU, and HDF images of the hepatic artery (HA), portal vein (PV), and hepatic vein from 60 patients. They were divided into 2 groups: a liver transplantation group (group 1, n = 10) and a native liver group (group 2, n = 50). Two radiologists independently reviewed the cine images and graded them using a 4-point scale in terms of the clarity of the vessel margin and degree of depiction of the HA, flow filling, and flash artifacts. The degree of differentiation between the HA and PV was also evaluated. Flow directionality was recorded, and interobserver agreement was finally analyzed. Moderate to almost perfect agreement was achieved between radiologists for all parameters of each ultrasonographic technique. High-definition flow was significantly superior to both CDU and PDU with respect to all analyzed items except the degree of flash artifacts (P < .05). With regard to flash artifacts, CDU was significantly better than either PDU or HDF. High-definition flow provided directional information, as did CDU. The HDF technique provides better resolution for depicting hepatic vessels as well as their margins with less blooming compared with conventional Doppler ultrasonography in both native and transplanted liver. It also provides solid directional flow information. One point of concern, however, is the frequency of flash artifacts compared with that on CDU.
Njemanze, Philip C
2010-11-30
The present study was designed to examine the effects of color stimulation on cerebral blood mean flow velocity (MFV) in men and women. The study included 16 (8 men and 8 women) right-handed healthy subjects. The MFV was recorded simultaneously in both right and left middle cerebral arteries in Dark and white Light conditions, and during color (Blue, Yellow and Red) stimulations, and was analyzed using functional transcranial Doppler spectroscopy (fTCDS) technique. Color processing occurred within cortico-subcortical circuits. In men, wavelength-differencing of Yellow/Blue pairs occurred within the right hemisphere by processes of cortical long-term depression (CLTD) and subcortical long-term potentiation (SLTP). Conversely, in women, frequency-differencing of Blue/Yellow pairs occurred within the left hemisphere by processes of cortical long-term potentiation (CLTP) and subcortical long-term depression (SLTD). In both genders, there was luminance effect in the left hemisphere, while in men it was along an axis opposite (orthogonal) to that of chromatic effect, in women, it was parallel. Gender-related differences in color processing demonstrated a right hemisphere cognitive style for wavelength-differencing in men, and a left hemisphere cognitive style for frequency-differencing in women. There are potential applications of fTCDS technique, for stroke rehabilitation and monitoring of drug effects.
SAMIR, Haney; SASAKI, Kazuaki; AHMED, Eman; KAREN, Aly; NAGAOKA, Kentaro; EL SAYED, Mohamed; TAYA, Kazuyoshi; WATANABE, Gen
2015-01-01
Although color Doppler ultrasonography has been used to evaluate testicular blood flow in many species, very little has been done in goat. Eight male Shiba goats were exposed to a single intramuscular injection of either gonadotropin-releasing hormone (GnRH group; 1 µg/kg BW) or human chorionic gonadotropin (hCG group; 25 IU/kg BW). Plasma testosterone (T), estradiol (E2) and inhibin (INH) were measured just before (0 hr) and at different intervals post injection by radioimmunoassay. Testis volume (TV) and Doppler indices, such as resistive index (RI) and pulsatility index (PI) of the supratesticular artery, were measured by B-mode and color Doppler ultrasonography, respectively. The results indicated an increase in testicular blood flow in both groups, as RI and PI decreased significantly (P<0.05), but this increase was significant higher and earlier in hCG group (1 hr) than in the GnRH group (2 hr). A high correlation was found for RI and PI with both T (RI, r= −0.862; PI, r= −0.707) and INH in the GnRH group (RI, r=0.661; PI, r=0.701). However, a significant (P<0.05) correlation was found between E2 and both RI (r= −0.610) and PI (r= −0.763) in hCG group. In addition, TV significantly increased and was highly correlated with RI in both groups (GnRH, r= −0.718; hCG, r= −0.779). In conclusion, hCG and GnRH may improve testicular blood flow and TV in Shiba goats. PMID:25715956
Hassani, Hakim; Raynal, Gauthier; Spie, Romain; Daudon, Michel; Vallée, Jean-Noël
2012-05-01
We evaluated the value of combining noncontrast helical computerized tomography (NCHCT) and color Doppler ultrasound in the assessment of the composition of urinary stones. In vitro, we studied 120 stones of known composition, that separate into the five main types: 18 calcium oxalate monohydrate (COM) stones, 41 calcium oxalate dihydrate (COD) stones, 24 uric acid stones, 25 calcium phosphate stones and 12 cystine calculi. Stones were characterized in terms of their Hounsfield density (HU) in NCHCT and the presence of a twinkling artifact (TA) in color Doppler ultrasound. There were statistically significant HU differences between calcium and non-calcium stones (p < 0.001), calcium oxalate stones and calcium phosphate stones (p < 0.001) and uric acid stones and cystine calculi (p < 0.001) but not between COM and COD stones (p = 0.786). Hence, the HU was a predictive factor of the composition of all types of stones, other than for COM and COD stones within the calcium oxalate class (p > 0.05). We found that the TA does not enable differentiation between calcium and non-calcium stones (p > 0.999), calcium oxalate stones and calcium phosphate stones (p = 0.15), or uric acid stones and cystine calculi (p = 0.079). However, it did reveal a significant difference between COM and COD stones (p = 0.002). The absence of a TA is a predictive factor for the presence of COM stones (p = 0.008). Hence, the association of NCHCT and Doppler enables the accurate classification of the five types of stones in vitro. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Photoacoustic Doppler effect from flowing small light-absorbing particles.
Fang, Hui; Maslov, Konstantin; Wang, Lihong V
2007-11-02
From the flow of a suspension of micrometer-scale carbon particles, the photoacoustic Doppler shift is observed. As predicted theoretically, the observed Doppler shift equals half of that in Doppler ultrasound and does not depend on the direction of laser illumination. This new physical phenomenon provides a basis for developing photoacoustic Doppler flowmetry, which can potentially be used for detecting fluid flow in optically scattering media and especially low-speed blood flow of relatively deep microcirculation in biological tissue.
Digital storage and analysis of color Doppler echocardiograms
NASA Technical Reports Server (NTRS)
Chandra, S.; Thomas, J. D.
1997-01-01
Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.
Lemercier, E; Genevois, A; Descargue, G; Clavier, E; Benozio, M
1999-04-01
Placenta accreta results from an abnormal attachment of the placenta to the uterine myometrium. The reported incidence in literature is variable, with an average of 1/7000 pregnancies. This condition is associated with a significant risk of bleeding at the time of delivery, usually requiring hysterectomy. Sonography associated with color Doppler is useful for diagnosis, but MRI can be used successfully to evaluate the degree of placental tissue invading into the myometrium, the serosa, and for follow-up after conservative management. To our knowledge, only two cases of placenta accreta evaluated with MR and six cases of placenta accreta treated by embolization have been reported in the literature. The authors report one case of placenta accreta treated successfully by embolization, and followed-up by MRI.
B-Flow Imaging in Lower Limb Peripheral Arterial Disease and Bypass Graft Ultrasonography.
D'Abate, Fabrizio; Ramachandran, Veni; Young, Mark A; Farrah, John; Ahmed, Mudasar H; Jones, Keith; Hinchliffe, Robert J
2016-09-01
Doppler ultrasonography plays a key role in the diagnosis of peripheral arterial disease, but is often limited by pitfalls that may be overcome by B-flow imaging. Thus far, there is little information on B-flow imaging for the assessment of peripheral arterial disease and bypass grafts in lower limbs. This article describes the authors' early experience with B-flow in the lower extremities. Sixty patients were included among a large cohort of patients routinely referred to the vascular laboratory for peripheral arterial disease and bypass graft assessments. Two experienced vascular sonographers performed all scans, comparing color Doppler ultrasonography with B-flow imaging. All scans were performed using a combination of the 9 L linear and C2-9 curvilinear transducers with the LOGIQ E9 system (GE Healthcare, Waukesha, WI, USA). Our experience indicates that this relatively unexplored technology has the potential to significantly improve peripheral blood flow evaluation. Nevertheless, B-flow imaging is not exempt from limitations and should be considered complementary to color Doppler ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Objective breast tissue image classification using Quantitative Transmission ultrasound tomography
NASA Astrophysics Data System (ADS)
Malik, Bilal; Klock, John; Wiskin, James; Lenox, Mark
2016-12-01
Quantitative Transmission Ultrasound (QT) is a powerful and emerging imaging paradigm which has the potential to perform true three-dimensional image reconstruction of biological tissue. Breast imaging is an important application of QT and allows non-invasive, non-ionizing imaging of whole breasts in vivo. Here, we report the first demonstration of breast tissue image classification in QT imaging. We systematically assess the ability of the QT images’ features to differentiate between normal breast tissue types. The three QT features were used in Support Vector Machines (SVM) classifiers, and classification of breast tissue as either skin, fat, glands, ducts or connective tissue was demonstrated with an overall accuracy of greater than 90%. Finally, the classifier was validated on whole breast image volumes to provide a color-coded breast tissue volume. This study serves as a first step towards a computer-aided detection/diagnosis platform for QT.
Role of Color Flow Ultrasound in Detection of Deep Venous Thrombosis
ERIC Educational Resources Information Center
Mohammed, Shelan Hakeem; AL-Najjar, Salwa A.
2016-01-01
Background: Deep vein thrombosis (DVT) of lower limbs is one of the most causes for the majority of death caused by pulmonary embolism. Many medical and surgical disorders are complicated by DVT. Most venous thrombi are clinically silent. B-mode and color Doppler imaging is needed for early diagnosis of DVT to prevent complications and squeal of…
Color Coded Cards for Student Behavior Management in Higher Education Environments
ERIC Educational Resources Information Center
Alhalabi, Wadee; Alhalabi, Mobeen
2017-01-01
The Color Coded Cards system as a possibly effective class management tool is the focus of this research. The Color Coded Cards system involves each student being given a card with a specific color based on his or her behavior. The main objective of the research is to find out whether this system effectively improves students' behavior, thus…
Pirat, B; Bozbas, H; Demirtas, S; Simsek, V; Sayin, B; Colak, T; Sade, E; Ulucam, M; Muderrisoglu, H; Haberal, M
2008-01-01
Tissue Doppler echocardiography has been introduced as a useful tool to assess systolic myocardial function. In this study we sought to compare patients with end-stage renal disease (ESRD), with renal transplantations and control subjects with regard to tissue Doppler parameters. Thirty recipients with functional grafts of overall mean age 36 +/- 7 years included 24 men. An equal number of patients with ESRD of overall mean age 35 +/- 7 years included 20 men. A third cohort was comprised of 20 age- and gender matched control subjects. Tissue Doppler imaging from the septal and lateral mitral annulus of the left ventricle and free wall of the right ventricle was performed from a 4-chamber view. Mean systolic and diastolic blood pressures were similar among the groups during imaging. Peak systolic velocity (S wave) at the septal annulus was similar in control subjects and recipients. S waves were significantly lower among ESRD patients compared with recipients (10.3 +/- 2.1 vs 12.0 +/- 2.5 cm/s, P = .04, respectively). Isovolumic contraction velocity of the septum and the right ventricular wall were significantly lower in ESRD patients than recipients or controls: 10.2 +/- 2.6 vs 12.5 +/- 2.8 vs 11.4 +/- 1.8 cm/s for septal wall (P = .008) and 13.9 +/- 3.6 vs 17.9 +/- 5.1 vs 16.8 +/- 5.8, for right ventricle (P = .01). Systolic indices of tissue Doppler echocardiography in recipients demonstrated similar values as control subjects and increased values compared with ESRD patients. These results suggested improvement in systolic myocardial function following renal transplantation.
Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies
2017-10-01
To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p < 0.001). After 1 month, left ventricular end diastolic diameter and left atrium diameter to aortic annulus ratio continued to decrease, while ejection fraction and fractional shortening improved significantly. All tissue Doppler velocities showed a significant decrease at 48 hours with significant prolongation of global myocardial function ( p < 0.001) and then were normalized within 1 month postclosure. Similarly, global longitudinal strain significantly decreased at 48 hours postclosure ( p < 0.001), which also recovered at 1 month follow-up. Preclosure global longitudinal strain showed a good correlation with the postclosure prolongation of the myocardial performance index. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure, which recovers completely within 1 month. Preclosure global longitudinal strain can be a predictor of postclosure myocardial dysfunction.
NASA Astrophysics Data System (ADS)
Assi, Kondo Claude; Gay, Etienne; Chnafa, Christophe; Mendez, Simon; Nicoud, Franck; Abascal, Juan F. P. J.; Lantelme, Pierre; Tournoux, François; Garcia, Damien
2017-09-01
We propose a regularized least-squares method for reconstructing 2D velocity vector fields within the left ventricular cavity from single-view color Doppler echocardiographic images. Vector flow mapping is formulated as a quadratic optimization problem based on an {{\\ell }2} -norm minimization of a cost function composed of a Doppler data-fidelity term and a regularizer. The latter contains three physically interpretable expressions related to 2D mass conservation, Dirichlet boundary conditions, and smoothness. A finite difference discretization of the continuous problem was adopted in a polar coordinate system, leading to a sparse symmetric positive-definite system. The three regularization parameters were determined automatically by analyzing the L-hypersurface, a generalization of the L-curve. The performance of the proposed method was numerically evaluated using (1) a synthetic flow composed of a mixture of divergence-free and curl-free flow fields and (2) simulated flow data from a patient-specific CFD (computational fluid dynamics) model of a human left heart. The numerical evaluations showed that the vector flow fields reconstructed from the Doppler components were in good agreement with the original velocities, with a relative error less than 20%. It was also demonstrated that a perturbation of the domain contour has little effect on the rebuilt velocity fields. The capability of our intraventricular vector flow mapping (iVFM) algorithm was finally illustrated on in vivo echocardiographic color Doppler data acquired in patients. The vortex that forms during the rapid filling was clearly deciphered. This improved iVFM algorithm is expected to have a significant clinical impact in the assessment of diastolic function.
Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
NASA Astrophysics Data System (ADS)
Adair, Henry S., III
1998-07-01
Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.
Joint sparse coding based spatial pyramid matching for classification of color medical image.
Shi, Jun; Li, Yi; Zhu, Jie; Sun, Haojie; Cai, Yin
2015-04-01
Although color medical images are important in clinical practice, they are usually converted to grayscale for further processing in pattern recognition, resulting in loss of rich color information. The sparse coding based linear spatial pyramid matching (ScSPM) and its variants are popular for grayscale image classification, but cannot extract color information. In this paper, we propose a joint sparse coding based SPM (JScSPM) method for the classification of color medical images. A joint dictionary can represent both the color information in each color channel and the correlation between channels. Consequently, the joint sparse codes calculated from a joint dictionary can carry color information, and therefore this method can easily transform a feature descriptor originally designed for grayscale images to a color descriptor. A color hepatocellular carcinoma histological image dataset was used to evaluate the performance of the proposed JScSPM algorithm. Experimental results show that JScSPM provides significant improvements as compared with the majority voting based ScSPM and the original ScSPM for color medical image classification. Copyright © 2014 Elsevier Ltd. All rights reserved.
Effect of Doppler flow meter position on discharge measurement in surcharged manholes.
Yang, Haoming; Zhu, David Z; Liu, Yanchen
2018-02-01
Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.
Bishai, John M; Blood, Arlin B; Hunter, Christian J; Longo, Lawrence D; Power, Gordon G
2003-01-01
This study was undertaken to compare microsphere and laser Doppler flowmetry techniques for the measurement of cerebral blood flow, to assess the effect of probe implantation at the tip of the sensing probe and to measure brain tissue PO2 (tPO2) in response to acute hypoxia. Fetal sheep of ≈131 days gestation (n = 8) were chronically instrumented with bilateral laser Doppler probes in the parietal cortices and catheters for injection of fluorescent microspheres. Five days after surgery fetuses were subjected to 1 h periods of baseline control breathing, hypoxia and recovery. Microspheres were injected 10 min prior to and 10, 30, 50 and 120 min after initiation of hypoxia. Microspheres were counted in four 12 mm3 tissue samples from each hemisphere, the tip of the laser Doppler probe being positioned in the centre of one of the cubes. The cube containing the probe tip was also subdivided into 4 mm3 pieces of tissue. In response to hypoxia, fetal arterial PO2 declined from 21 ± 2 to 12 ± 1 Torr and brain tissue PO2 fell from 10 ± 1 to a nadir of 1 ± 1 Torr. Each method detected a significant increase in CBF that reached a maximum after 30–45 min, although the increase of flow measured by laser Doppler flowmetry was less than that measured by spheres after 10 and 30 min (P < 0.05). Microspheres did not detect altered flow at the probe tip or heterogeneity of flow in surrounding volumes of cortical tissue. In summary, laser Doppler flowmetry is a useful measure of continuous relative changes of CBF in the chronically instrumented fetal sheep. Flow compensations in acute hypoxia are not adequate to sustain O2 delivery, and other compensations, including reduced metabolic rate, are possible. PMID:12563011
Liu, Lei; Funamoto, Kenichi; Tanabe, Masayuki; Hayase, Toshiyuki
2013-01-01
The twinkling sign (TS) observed in ultrasound imaging (e.g., color flow mode and pulse Doppler mode) has been reported in previous researches as a potential phenomenon to detect micro calcification in soft tissue. However, the mechanism of the twinkling sign has not been clearly understood yet. The authors investigated the effect of stiffness of surrounding tissue on the appearance of TS using the soft tissue-mimicking phantoms and a medical ultrasound device. The author used Poly (vinyl alcohol) hydro (PVA-H) gel as the material of phantom and developed three phantoms with different PVA concentration; 8 %wt, 10 %wt and 15 %wt those correspond to Young's modulus (E) as 50 kPa, 100 kPa and 230 kPa, respectively. Micro glass and CaCO3 particles were embedded in the phantoms as pseudo micro calcification. The authors observed TS in each phantom and analyzed the temporal average of TS. The temporal average of TS was largest in the 8 %wt (E = 50 kPa) PVA-H gel phantom, and decreased with increasing the phantom stiffness. The result indicated that the micro oscillation of the particles had a close relationship with the occurrence of TS.
Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
Gimber, Lana H.; Becker, Giles W.; Latt, L. Daniel; Klauser, Andrea S.; Melville, David M.; Gao, Liang; Witte, Russell S.
2017-01-01
In the past 2 decades, sonoelastography has been progressively used as a tool to help evaluate soft-tissue elasticity and add to information obtained with conventional gray-scale and Doppler ultrasonographic techniques. Recently introduced on clinical scanners, shear-wave elastography (SWE) is considered to be more objective, quantitative, and reproducible than compression sonoelastography with increasing applications to the musculoskeletal system. SWE uses an acoustic radiation force pulse sequence to generate shear waves, which propagate perpendicular to the ultrasound beam, causing transient displacements. The distribution of shear-wave velocities at each pixel is directly related to the shear modulus, an absolute measure of the tissue’s elastic properties. Shear-wave images are automatically coregistered with standard B-mode images to provide quantitative color elastograms with anatomic specificity. Shear waves propagate faster through stiffer contracted tissue, as well as along the long axis of tendon and muscle. SWE has a promising role in determining the severity of disease and treatment follow-up of various musculoskeletal tissues including tendons, muscles, nerves, and ligaments. This article describes the basic ultrasound physics of SWE and its applications in the evaluation of various traumatic and pathologic conditions of the musculoskeletal system. ©RSNA, 2017 PMID:28493799
Doppler Spectra of Bistatic Reverberation from the Sea Surface.
1979-05-08
GOVT ACCESSIN NO RECIPIENTS8 CATALOG NUMBER S. TtE ... wuw~tP RED DOPPLER .&PECTRA OF JISTATIC REVERBEATION( 9; t - .e:. TROM THE SEA SURFACE...National Resear-h Council, Committee Undersea Warfare 1 Woods Hole Oceanographic Institution 1 NORDA Code 110, 200, 300, 500, 600 5 DDC, Alexandria 12
A blind dual color images watermarking based on IWT and state coding
NASA Astrophysics Data System (ADS)
Su, Qingtang; Niu, Yugang; Liu, Xianxi; Zhu, Yu
2012-04-01
In this paper, a state-coding based blind watermarking algorithm is proposed to embed color image watermark to color host image. The technique of state coding, which makes the state code of data set be equal to the hiding watermark information, is introduced in this paper. When embedding watermark, using Integer Wavelet Transform (IWT) and the rules of state coding, these components, R, G and B, of color image watermark are embedded to these components, Y, Cr and Cb, of color host image. Moreover, the rules of state coding are also used to extract watermark from the watermarked image without resorting to the original watermark or original host image. Experimental results show that the proposed watermarking algorithm cannot only meet the demand on invisibility and robustness of the watermark, but also have well performance compared with other proposed methods considered in this work.
29 CFR 1915.90 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 7 2013-07-01 2013-07-01 false Safety color code for marking physical hazards. 1915.90 Section 1915.90 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... General Working Conditions § 1915.90 Safety color code for marking physical hazards. The requirements...
29 CFR 1915.90 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 7 2014-07-01 2014-07-01 false Safety color code for marking physical hazards. 1915.90 Section 1915.90 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... General Working Conditions § 1915.90 Safety color code for marking physical hazards. The requirements...
29 CFR 1915.90 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 7 2012-07-01 2012-07-01 false Safety color code for marking physical hazards. 1915.90 Section 1915.90 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... General Working Conditions § 1915.90 Safety color code for marking physical hazards. The requirements...
2010-01-01
Introduction We describe the case of a 79-year-old Caucasian Italian woman with a transient basilar occlusion monitored by transcranial Doppler, with subsequent recanalization and clinical shrinking deficit. This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. This case is important and needs to be reported because transient basilar occlusion may be easily diagnosed if transcranial Doppler is performed. Case presentation A 79-year-old woman affected by chronic atrial fibrillation and not treated with oral anticoagulants, cardioverted to sinus rhythm during a gastric endoscopy. She then showed a sudden-onset loss of consciousness, horizontal and vertical gaze palsy, tetraparesis and bilateral miosis and coma. Two hours later, the symptoms resolved quickly, leaving no residual neurologic deficits. Transcranial Doppler examination showed a dampened flow in the basilar artery in the emergency examination and a restored flow when the symptoms resolved. Conclusion This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. We believe that transcranial Doppler should be performed in all cases of unexplained acute loss of consciousness, in particular, if associated with signs of brainstem dysfunctions. PMID:20205759
Tidholm, A; Nicolle, A P; Carlos, C; Gouni, V; Caruso, J L; Pouchelon, J L; Chetboul, V
2004-04-01
A mitral valve stenosis was diagnosed in a 2-year-old female Bull Terrier by use of two-dimensional (2-D) and M-mode echocardiography, colour-flow imaging and spectral Doppler examinations. Tissue Doppler Imaging was also performed to assess the segmental radial myocardial motion. The mitral valve stenosis was characterized by a decreased mitral orifice area/left ventricle area ratio (0.14), an increased early diastolic flow velocity (E wave = 1.9 m/s), a prolonged pressure half-time (106 ms) and a decreased E-F slope (4.5 cm/s) on pulsed-wave Doppler examination. This mitral stenosis was associated with an immobile posterior leaflet, as seen on 2-D and M-mode echocardiography. Immobility of the posterior mitral leaflet is considered to be a rare finding in humans and, to our knowledge, has not been precisely documented in dogs with mitral valve stenosis.
Chetboul, Valérie; Gouni, Vassiliki; Sampedrano, Carolina Carlos; Tissier, Renaud; Serres, François; Pouchelon, Jean-Louis
2007-01-01
Tissue Doppler Imaging (TDI) or strain (St) imaging could provide sensitive indices for early detection and treatment follow-up of canine dilated cardiomyopathy (DCM). Analysis of TDI and St features in dogs with overt DCM is a prerequisite before using these new criteria in prospective screenings of predisposed families or in clinical trials. Radial and longitudinal right and left myocardial motion, assessed by TDI and St variables, is altered in dogs with DCM. Case records for 26 dogs; 14 with DCM and 12 healthy controls of comparable age and weight were reviewed. A retrospective analysis was conducted of conventional echocardiography, 2-dimensional color TDI, and St imaging data. The DCM group was characterized by decreases in radial and longitudinal systolic velocity gradients of the left ventricular free wall (LVFW), radial and longitudinal absolute values of peak systolic St of the LVFW, and longitudinal systolic right ventricular (RV) velocities (all P < .001 versus control) associated with longitudinal postsystolic contraction waves in 7/14 dogs. Early diastolic LVFW velocities also were decreased for longitudinal (P < .01) and radial (P < .05) motions. All radial LVFW, longitudinal basal LVFW, and RV systolic velocities were negatively correlated with heart rate (P < .01). LV contractility along both the short and long axes is impaired in dogs with spontaneous DCM, as is systolic RV and diastolic LVFW function. These myocardial alterations are associated with an inverse force-frequency relationship. Studies now are needed to determine the comparative sensitivity of TDI and St variables for the early detection of canine DCM.
Doppler and speckle methods for diagnostics in dentistry
NASA Astrophysics Data System (ADS)
Ulyanov, Sergey S.; Lepilin, Alexander V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Kharish, Natalia A.; Osipova, Yulia; Karpovich, Alexander
2002-02-01
The results of statistical analysis of Doppler spectra of scattered intensity, obtained from tissues of oral cavity membrane of healthy volunteers, are presented. The dependence of the spectral moments of Doppler signal on cutoff frequency is investigated. Some results of statistical analysis of Doppler spectra, obtained from tooth pulp of patients, are presented. New approach for monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of measuring system on formation of speckle-interferometric signal is studied.
Accuracy of three-dimensional multislice view Doppler in diagnosis of morbid adherent placenta
Abdel Moniem, Alaa M.; Ibrahim, Ahmed; Akl, Sherif A.; Aboul-Enen, Loay; Abdelazim, Ibrahim A.
2015-01-01
Objective To detect the accuracy of the three-dimensional multislice view (3D MSV) Doppler in the diagnosis of morbid adherent placenta (MAP). Material and Methods Fifty pregnant women at ≥28 weeks gestation with suspected MAP were included in this prospective study. Two dimensional (2D) trans-abdominal gray-scale ultrasound scan was performed for the subjects to confirm the gestational age, placental location, and findings suggestive of MAP, followed by the 3D power Doppler and then the 3D MSV Doppler to confirm the diagnosis of MAP. Intraoperative findings and histopathology results of removed uteri in cases managed by emergency hysterectomy were compared with preoperative sonographic findings to detect the accuracy of the 3D MSV Doppler in the diagnosis of MAP. Results The 3D MSV Doppler increased the accuracy and predictive values of the diagnostic criteria of MAP compared with the 3D power Doppler. The sensitivity and negative predictive value (NPV) (79.6% and 82.2%, respectively) of crowded vessels over the peripheral sub-placental zone to detect difficult placental separation and considerable intraoperative blood loss in cases of MAP using the 3D power Doppler was increased to 82.6% and 84%, respectively, using the 3D MSV Doppler. In addition, the sensitivity, specificity, and positive predictive value (PPV) (90.9%, 68.8%, and 47%, respectively) of the disruption of the uterine serosa-bladder interface for the detection of emergency hysterectomy in cases of MAP using the 3D power Doppler was increased to 100%, 71.8%, and 50%, respectively, using the 3D MSV Doppler. Conclusion The 3D MSV Doppler is a useful adjunctive tool to the 3D power Doppler or color Doppler to refine the diagnosis of MAP. PMID:26401104
Color visualization for fluid flow prediction
NASA Technical Reports Server (NTRS)
Smith, R. E.; Speray, D. E.
1982-01-01
High-resolution raster scan color graphics allow variables to be presented as a continuum, in a color-coded picture that is referenced to a geometry such as a flow field grid or a boundary surface. Software is used to map a scalar variable such as pressure or temperature, defined on a two-dimensional slice of a flow field. The geometric shape is preserved in the resulting picture, and the relative magnitude of the variable is color-coded onto the geometric shape. The primary numerical process for color coding is an efficient search along a raster scan line to locate the quadrilteral block in the grid that bounds each pixel on the line. Tension spline interpolation is performed relative to the grid for specific values of the scalar variable, which is then color coded. When all pixels for the field of view are color-defined, a picture is played back from a memory device onto a television screen.
Color Doppler imaging of the retrobulbar circulation in progressive glaucoma optic neuropathy.
Magureanu, Marineta; Stanila, Adriana; Bunescu, Liviu Valentin; Armeanu, Cristina
2016-01-01
It is known that elevated intraocular pressure (IOP) is the primary risk factor for glaucoma. Recently, more and more evidences have shown that the vascular deficit also plays an important role in the pathogenesis and progressions of glaucomatous optic neuropathy. This issue is backed up by glaucomatous optic neuropathy (GON) cases drug compensated in which the progression of the disease in one or both eyes is ascertained despite a normal and relatively constant IOP. The present study evaluated the hemodynamic parameters in the retrobulbar circulation in patients with progressive glaucomatous optic neuropathy in one eye, who received compensated medication. The hemodynamic parameters (PSV, EDV, IR) were measured by using color Doppler ultrasound and progression was evaluated by a repeated automated perimetry. The obtained values were statistically analyzed and compared with those obtained for the stable eye.
Hands-Free Transcranial Color Doppler Probe
NASA Technical Reports Server (NTRS)
Chin, Robert; Madala, Srihdar; Sattler, Graham
2012-01-01
Current transcranial color Doppler (TCD) transducer probes are bulky and difficult to move in tiny increments to search and optimize TCD signals. This invention provides miniature motions of a TCD transducer probe to optimize TCD signals. The mechanical probe uses spherical bearing in guiding and locating the tilting crystal face. The lateral motion of the crystal face as it tilts across the full range of motion was achieved by minimizing the distance between the pivot location and the crystal face. The smallest commonly available metal spherical bearing was used with an outer diameter of 12 mm, a 3-mm tall retaining ring, and 5-mm overall height. Small geared motors were used that would provide sufficient power in a very compact package. After confirming the validity of the basic positioning concept, optimization design loops were completed to yield the final design.
El Behery, Manal M; Rasha L, Etewa; El Alfy, Yehya
2010-04-01
To evaluate whether measuring cell-free placental mRNA in maternal plasma improves the diagnostic accuracy of ultrasound and color Doppler in detecting placental invasion in patients at risk for placenta accreta. Thirty-five singleton pregnant women of more than 28 weeks of gestation and at risk for placenta accreta underwent ultrasound and color Doppler assessment. Cell-free placental mRNA in maternal plasma was measured using real-time reverse-transcription polymerase chain reaction. Patients were classified into 2 groups based on the findings at cesarean delivery and histological examination: women with placenta accreta (n=7) and women without placenta accreta (n=28). The median MoM (multiples of the median) value of cell-free placental mRNA was significantly higher in patients with placenta accreta than in those without placenta accreta (6.50 vs 2.60; P<0.001. Moreover, cell-free placental mRNA was significantly elevated in patients with placenta increta and percreta than in those with simple accreta. Six false-positive results were found on ultrasound, all from patients without placenta accreta and an insignificant rise in cell-free placental mRNA levels. Measuring cell-free placental mRNA in maternal plasma may increase the accuracy of ultrasound and color Doppler in prenatal prediction of placental invasion in patients with suspected placenta accreta. Copyright 2009 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Teaching Speech Organization and Outlining Using a Color-Coded Approach.
ERIC Educational Resources Information Center
Hearn, Ralene
The organization/outlining unit in the basic Public Speaking course can be made more interesting by using a color-coded instructional method that captivates students, facilitates understanding, and provides the opportunity for interesting reinforcement activities. The two part lesson includes a mini-lecture with a color-coded outline and a two…
Imitation Learning Errors Are Affected by Visual Cues in Both Performance and Observation Phases.
Mizuguchi, Takashi; Sugimura, Ryoko; Shimada, Hideaki; Hasegawa, Takehiro
2017-08-01
Mechanisms of action imitation were examined. Previous studies have suggested that success or failure of imitation is determined at the point of observing an action. In other words, cognitive processing after observation is not related to the success of imitation; 20 university students participated in each of three experiments in which they observed a series of object manipulations consisting of four elements (hands, tools, object, and end points) and then imitated the manipulations. In Experiment 1, a specific intially observed element was color coded, and the specific manipulated object at the imitation stage was identically color coded; participants accurately imitated the color coded element. In Experiment 2, a specific element was color coded at the observation but not at the imitation stage, and there were no effects of color coding on imitation. In Experiment 3, participants were verbally instructed to attend to a specific element at the imitation stage, but the verbal instructions had no effect. Thus, the success of imitation may not be determined at the stage of observing an action and color coding can provide a clue for imitation at the imitation stage.
Contrast-enhanced endoscopic ultrasonography: advance and current status
2014-01-01
Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review. PMID:25038805
Ulnar nerve sonography in leprosy neuropathy.
Wang, Zhu; Liu, Da-Yue; Lei, Yang-Yang; Yang, Zheng; Wang, Wei
2016-01-01
A 23-year-old woman presented with a half-year history of right forearm sensory and motor dysfunction. Ultrasound imaging revealed definite thickening of the right ulnar nerve trunk and inner epineurium, along with heterogeneous hypoechogenicity and unclear nerve fiber bundle. Color Doppler exhibited a rich blood supply, which was clearly different from the normal ulnar nerve presentation with a scarce blood supply. The patient subsequently underwent needle aspiration of the right ulnar nerve, and histopathological examination confirmed that granulomatous nodules had formed with a large number of infiltrating lymphocytes and a plurality of epithelioid cells in the fibrous connective tissues, with visible atypical foam cells and proliferous vascularization, consistent with leprosy. Our report will familiarize readers with the characteristic sonographic features of the ulnar nerve in leprosy, particularly because of the decreasing incidence of leprosy in recent years.
Multigigahertz range-Doppler correlative processing in crystals
NASA Astrophysics Data System (ADS)
Harris, Todd L.; Babbitt, Wm. R.; Merkel, Kristian D.; Mohan, R. Krishna; Cole, Zachary; Olson, Andy
2004-06-01
Spectral-spatial holographic crystals have the unique ability to resolve fine spectral features (down to kilohertz) in an optical waveform over a broad bandwidth (over 10 gigahertz). This ability allows these crystals to record the spectral interference between spread spectrum waveforms that are temporally separated by up to several microseconds. Such crystals can be used for performing radar range-Doppler processing with fine temporal resolution. An added feature of these crystals is the long upper state lifetime of the absorbing rare earth ions, which allows the coherent integration of multiple recorded spectra, yielding integration gain and significant processing gain enhancement for selected code sets, as well as high resolution Doppler processing. Parallel processing of over 10,000 beams could be achieved with a crystal the size of a sugar cube. Spectral-spatial holographic processing and coherent integration of up to 2.5 Gigabit per second coded waveforms and of lengths up to 2047 bits has previously been reported. In this paper, we present the first demonstration of Doppler processing with these crystals. Doppler resolution down to a few hundred Hz for broadband radar signals can be achieved. The processing can be performed directly on signals modulated onto IF carriers (up to several gigahertz) without having to mix the signals down to baseband and without having to employ broadband analog to digital conversion.
Binzoni, Tiziano; Torricelli, Alessandro; Giust, Remo; Sanguinetti, Bruno; Bernhard, Paul; Spinelli, Lorenzo
2014-01-01
A bone tissue phantom prototype allowing to test, in general, optical flowmeters at large interoptode spacings, such as laser-Doppler flowmetry or diffuse correlation spectroscopy, has been developed by 3D-stereolithography technique. It has been demonstrated that complex tissue vascular systems of any geometrical shape can be conceived. Absorption coefficient, reduced scattering coefficient and refractive index of the optical phantom have been measured to ensure that the optical parameters reasonably reproduce real human bone tissue in vivo. An experimental demonstration of a possible use of the optical phantom, utilizing a laser-Doppler flowmeter, is also presented. PMID:25136496
Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo
2017-03-01
Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.
Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina
2012-01-01
Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.
Kutbay, Uğurhan; Hardalaç, Fırat; Akbulut, Mehmet; Akaslan, Ünsal; Serhatlıoğlu, Selami
2016-06-01
This study aims investigating adjustable distant fuzzy c-means segmentation on carotid Doppler images, as well as quaternion-based convolution filters and saliency mapping procedures. We developed imaging software that will simplify the measurement of carotid artery intima-media thickness (IMT) on saliency mapping images. Additionally, specialists evaluated the present images and compared them with saliency mapping images. In the present research, we conducted imaging studies of 25 carotid Doppler images obtained by the Department of Cardiology at Fırat University. After implementing fuzzy c-means segmentation and quaternion-based convolution on all Doppler images, we obtained a model that can be analyzed easily by the doctors using a bottom-up saliency model. These methods were applied to 25 carotid Doppler images and then interpreted by specialists. In the present study, we used color-filtering methods to obtain carotid color images. Saliency mapping was performed on the obtained images, and the carotid artery IMT was detected and interpreted on the obtained images from both methods and the raw images are shown in Results. Also these results were investigated by using Mean Square Error (MSE) for the raw IMT images and the method which gives the best performance is the Quaternion Based Saliency Mapping (QBSM). 0,0014 and 0,000191 mm(2) MSEs were obtained for artery lumen diameters and plaque diameters in carotid arteries respectively. We found that computer-based image processing methods used on carotid Doppler could aid doctors' in their decision-making process. We developed software that could ease the process of measuring carotid IMT for cardiologists and help them to evaluate their findings.
Comparison of memory thresholds for planar qudit geometries
NASA Astrophysics Data System (ADS)
Marks, Jacob; Jochym-O'Connor, Tomas; Gheorghiu, Vlad
2017-11-01
We introduce and analyze a new type of decoding algorithm called general color clustering, based on renormalization group methods, to be used in qudit color codes. The performance of this decoder is analyzed under a generalized bit-flip error model, and is used to obtain the first memory threshold estimates for qudit 6-6-6 color codes. The proposed decoder is compared with similar decoding schemes for qudit surface codes as well as the current leading qubit decoders for both sets of codes. We find that, as with surface codes, clustering performs sub-optimally for qubit color codes, giving a threshold of 5.6 % compared to the 8.0 % obtained through surface projection decoding methods. However, the threshold rate increases by up to 112% for large qudit dimensions, plateauing around 11.9 % . All the analysis is performed using QTop, a new open-source software for simulating and visualizing topological quantum error correcting codes.
Tiryakioglu, Selma Kenar; Tiryakioglu, Osman; Ari, Hasan; Basel, Mehmet Cem; Ozkan, Hakan; Bozat, Tahsin
2010-05-01
The aim of this study was to assess left ventricular (LV) myocardial regional function in overt hypothyroidism by use of tissue Doppler imaging and to compare the results to the hormonal profile and standard Doppler echocardiographic examination. Hypothyroidic (Group 1, n = 25) and euthyroidic patients (Group 2, n = 25) underwent transthorasic echocardiography, strain and strain rate imaging. Standard echocardiography showed that patients with overt hypothyroidism had significantly longer isovolumic contraction time (IVCT) (P < 0.05), deceleration time (DT) (P = 0.014) and isovolumic relaxation time (IVRT) (P = 0.022). Tissue Doppler imaging showed that the mean peak systolic strain (SI) (16.47 + or - 1.45 vs. 20.63 + or - 1.51, P < 0.001), the mean peak systolic strain rate (SSR) (1.05 + or - 0.13 vs. 1.47 + or - 0.11, P < 0.001), the mean peak early diastolic strain rate (ESr) (1.72 + or - 0.38 vs. 2.03 + or - 0.25, P < 0.05) and the mean peak late diastolic strain rate (ASr) (1.22 + or - 0.31 vs. 1.46 + or - 0.32, P < 0.05) were significantly lower in Group 1 compared to Group 2. For all patients, the systolic strain and systolic strain rate parameters negatively correlated with thyroid stimulating hormone levels and positively correlated with the levels of free triiodothyronine (fT(3)) and free tetraiodothyronine (fT(4)). These results indicate that overt hypothyroidism is associated with early impairment in LV longitudinal myocardial function, and that tissue Doppler echocardiography is useful for the grading of disease and detection of early impairment. (ECHOCARDIOGRAPHY 2010;27:505-511).
[Ultrasonography in acute pelvic pain].
Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim
2002-01-01
Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more accurate diagnosis of this entity since it enables differentiation between acute and chronic stages based on analysis of the vascular resistance. Hemorrhagic ovarian cysts may be presented by variety of ultrasound findings since intracystic echoes depend upon the quality and quantity of the blood clots. Color Doppler investigation demonstrates moderate to low vascular resistance typical of luteal flow. Leiomyomas undergoing degenerative changes are another cause of acute pelvic pain commonly present in patients of reproductive age. Color flow detects regularly separated vessels at the periphery of the leiomyoma, which exhibit moderate vascular resistance. Although the classic symptom of endometriosis is chronic pelvic pain, in some patients acute pelvic pain does occur. Most of these patients demonstrate an endometrioma or "chocolate" cyst containing diffuse carpet-like echoes. Sometimes, solid components may indicate even ovarian malignancy, but if color Doppler ultrasound is applied it is less likely to obtain false positive results. One should be aware that pericystic and/or hillar type of ovarian endometrioma vascularization facilitate correct recognition of this entity. Pelvic congestion syndrome is another condition that can cause an attack of acute pelvic pain. It is usually consequence of dilatation of venous plexuses, arteries or both systems. By switching color Doppler gynecologist can differentiate pelvic congestion syndrome from multilocular cysts, pelvic inflammatory disease or adenomyosis. Ovarian vein thrombosis is a potentially fatal disorder occurring most often in the early postpartal period. Hypercoagulability, infection and stasis are main etiologic factors, and transvaginal color Doppler ultrasound is an excellent diagnostic tool to diagnose it. Acute pelvic pain may occur even in normal intrauterine pregnancy. This may be explained by hormonal changes, rapid growth of the uterus and increased blood flow. Ultrasound is mandatory for distinguishing normal intrauterine pregnancy from threatened or spontaneous abortion, ectopic pregnancy and other complications that may occur in patients with positive pregnancy test. Incomplete abortion is visualized as thickened and irregular endometrial echo with certain amount of intracavitary fluid. If applied, color Doppler ultrasound reveals low vascular resistance signals in richly perfused intracavitary area. Transvaginal sonography has high sensitivity and specificity in visualization of uterine and adnexal signs of ectopic pregnancy. Color Doppler examination may aid in detection of the peritrophoblastic flow. Furthermore, it facilitates detection of ectopic living embryo, tubal ring or unspecific adnexal tumor. Corpus luteum cysts and leiomyomas are another cause of pelvic pain during pregnancy, which can be correctly diagnosed by ultrasound. Detection of uterine dehiscence and rupture in patients with history of prior surgical intervention on uterine wall relies exclusively on correct ultrasound diagnosis. In patients with placental abruption sonographer detects hypoechoic complex representing either retroplacental hematoma, subchorionic hematoma or subamniotic hemorrhage. In closing, ultrasound has already become important and easily available tool which can efficiently recognize patients with possibly threatening conditions of different origins.
Reading color barcodes using visual snakes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaub, Hanspeter
2004-05-01
Statistical pressure snakes are used to track a mono-color target in an unstructured environment using a video camera. The report discusses an algorithm to extract a bar code signal that is embedded within the target. The target is assumed to be rectangular in shape, with the bar code printed in a slightly different saturation and value in HSV color space. Thus, the visual snake, which primarily weighs hue tracking errors, will not be deterred by the presence of the color bar codes in the target. The bar code is generate with the standard 3 of 9 method. Using this method,more » the numeric bar codes reveal if the target is right-side-up or up-side-down.« less
Wang, Lutao; Xiao, Jun; Chai, Hua
2015-08-01
The successful suppression of clutter arising from stationary or slowly moving tissue is one of the key issues in medical ultrasound color blood imaging. Remaining clutter may cause bias in the mean blood frequency estimation and results in a potentially misleading description of blood-flow. In this paper, based on the principle of general wall-filter, the design process of three classes of filters, infinitely impulse response with projection initialization (Prj-IIR), polynomials regression (Pol-Reg), and eigen-based filters are previewed and analyzed. The performance of the filters was assessed by calculating the bias and variance of a mean blood velocity using a standard autocorrelation estimator. Simulation results show that the performance of Pol-Reg filter is similar to Prj-IIR filters. Both of them can offer accurate estimation of mean blood flow speed under steady clutter conditions, and the clutter rejection ability can be enhanced by increasing the ensemble size of Doppler vector. Eigen-based filters can effectively remove the non-stationary clutter component, and further improve the estimation accuracy for low speed blood flow signals. There is also no significant increase in computation complexity for eigen-based filters when the ensemble size is less than 10.
Yano, Shuya; Hiroshima, Yukihiko; Maawy, Ali; Kishimoto, Hiroyuki; Suetsugu, Atsushi; Miwa, Shinji; Toneri, Makoto; Yamamoto, Mako; Katz, Matthew H.G.; Fleming, Jason B.; Urata, Yasuo; Tazawa, Hiroshi; Kagawa, Shunsuke; Bouvet, Michael; Fujiwara, Toshiyoshi; Hoffman, Robert M.
2015-01-01
Precise fluorescence-guided surgery (FGS) for pancreatic cancer has the potential to greatly improve the outcome in this recalcitrant disease. In order to achieve this goal, we have used genetic reporters to color code cancer and stroma cells in a patient-derived orthotopic xenograft (PDOX) model. The telomerase-dependent green fluorescent protein (GFP) containing adenovirus OBP401 was used to label the cancer cells of the pancreatic cancer PDOX. The PDOX was previously grown in a red fluorescent protein (RFP) transgenic mouse that stably labeled the PDOX stroma cells bright red. The color-coded PDOX model enabled FGS to completely resect the pancreatic tumors including stroma. Dual-colored FGS significantly prevented local recurrence, which bright-light surgery (BLS) or single color could not. FGS, with color-coded cancer and stroma cells has important potential for improving the outcome of recalcitrant cancer. PMID:26088297
ERIC Educational Resources Information Center
Geigle, Bryce A.
2014-01-01
The aim of this thesis is to investigate and present the status of student synthesis with color coded formula writing for grade level six through twelve, and to make recommendations for educators to teach writing structure through a color coded formula system in order to increase classroom engagement and lower students' affect. The thesis first…
Parametric color coding of digital subtraction angiography.
Strother, C M; Bender, F; Deuerling-Zheng, Y; Royalty, K; Pulfer, K A; Baumgart, J; Zellerhoff, M; Aagaard-Kienitz, B; Niemann, D B; Lindstrom, M L
2010-05-01
Color has been shown to facilitate both visual search and recognition tasks. It was our purpose to examine the impact of a color-coding algorithm on the interpretation of 2D-DSA acquisitions by experienced and inexperienced observers. Twenty-six 2D-DSA acquisitions obtained as part of routine clinical care from subjects with a variety of cerebrovascular disease processes were selected from an internal data base so as to include a variety of disease states (aneurysms, AVMs, fistulas, stenosis, occlusions, dissections, and tumors). Three experienced and 3 less experienced observers were each shown the acquisitions on a prerelease version of a commercially available double-monitor workstation (XWP, Siemens Healthcare). Acquisitions were presented first as a subtracted image series and then as a single composite color-coded image of the entire acquisition. Observers were then asked a series of questions designed to assess the value of the color-coded images for the following purposes: 1) to enhance their ability to make a diagnosis, 2) to have confidence in their diagnosis, 3) to plan a treatment, and 4) to judge the effect of a treatment. The results were analyzed by using 1-sample Wilcoxon tests. Color-coded images enhanced the ease of evaluating treatment success in >40% of cases (P < .0001). They also had a statistically significant impact on treatment planning, making planning easier in >20% of the cases (P = .0069). In >20% of the examples, color-coding made diagnosis and treatment planning easier for all readers (P < .0001). Color-coding also increased the confidence of diagnosis compared with the use of DSA alone (P = .056). The impact of this was greater for the naïve readers than for the expert readers. At no additional cost in x-ray dose or contrast medium, color-coding of DSA enhanced the conspicuity of findings on DSA images. It was particularly useful in situations in which there was a complex flow pattern and in evaluation of pre- and posttreatment acquisitions. Its full potential remains to be defined.
Low Cost Coherent Doppler Lidar Data Acquisition and Processing
NASA Technical Reports Server (NTRS)
Barnes, Bruce W.; Koch, Grady J.
2003-01-01
The work described in this paper details the development of a low-cost, short-development time data acquisition and processing system for a coherent Doppler lidar. This was done using common laboratory equipment and a small software investment. This system provides near real-time wind profile measurements. Coding flexibility created a very useful test bed for new techniques.
Arterial stiffness and cardiac functions in patients with chronic venous disease.
Ozpelit, E; Ozpelit, M E; Albayrak, G; Karabay, O; Nesli Sahin, B; Gonencer, J Z; Badak, O
2015-12-01
Although the venous system is in direct continuity with the heart and the arterial system, it is not known whether chronic venous disease (CVD) has any impact on either of these. The aims of this study were to investigate the global functions of the left and right heart, and also arterial stiffness parameters in patients with CVD. Forty-eight patients with primary stage C4-C6 CVD were enrolled into the study. The control group consisted of 39 age/sex and Body Mass Index matched healthy volunteers. All of the patients underwent detailed echocardiographic examination with further focus on Doppler and tissue Doppler (TD) parameters of the left and right ventricle. Arterial stiffness was evaluated via applanation tonometry in each patient. The left atrial area (LAA) and interventricular septum thickness were slightly increased in patients with CVD. Regarding Doppler and tissue Doppler measurements of the LV, all of the parameters were similar among the groups, while RV tissue Doppler systolic velocity and TAPSE were higher in patients with CVD. Among the arterial stiffness parameters, central aortic pressure, augmentation index, and pulse wave velocity were slightly higher in patients with CVD. The results of this study indicated that CVD may be associated with a subclinical disease state in the arterial system and also in the heart. Further studies are needed to confirm this association and to describe the possible mechanisms.
Genetic variation of the porcine NR5A1 is associated with meat color.
Görres, Andreas; Ponsuksili, Siriluck; Wimmers, Klaus; Muráni, Eduard
2016-02-01
Because of the central role of Steroidogenic factor 1 in the regulation of the development and function of steroidogenic tissues, including the adrenal gland, we chose the encoding gene NR5A1 as a candidate for stress response, meat quality and carcass composition in the domestic pig. To identify polymorphisms of the porcine NR5A1 we comparatively sequenced the coding, untranslated and regulatory regions in four commercial pig lines. Single nucleotide polymorphisms could be found in the 3' UTR and in an intronic enhancer, whereas no polymorphisms were detected in the proximal promoter and coding region. A subset of the detected polymorphisms was genotyped in Piétrain x (German Large White x German Landrace) and German Landrace pigs. For the same animals, carcass composition traits, meat quality characteristics and parameters of adrenal function were recorded. Associations with meat color were found for two of the discovered SNPs in Piétrain x (German Large White x German Landrace) and German Landrace pigs but no connections to parameters of adrenal function could be established. We conclude that NR5A1 variations influence meat color in a hypothalamus-pituitary-adrenal axis independent manner and that further regulatory regions need to be analyzed for genetic variations to understand the discovered effects.
Colorful Revision: Color-Coded Comments Connected to Instruction
ERIC Educational Resources Information Center
Mack, Nancy
2013-01-01
Many teachers have had a favorable response to their experimentation with digital feedback on students' writing. Students much preferred a simpler system of highlighting and commenting in color. After experimentation the author found that this color-coded system was more effective for them and less time-consuming for her. Of course, any system…
Color Doppler imaging of retinal diseases.
Dimitrova, Galina; Kato, Satoshi
2010-01-01
Color Doppler imaging (CDI) is a widely used method for evaluating ocular circulation that has been used in a number of studies on retinal diseases. CDI assesses blood velocity parameters by using ultrasound waves. In ophthalmology, these assessments are mainly performed on the retrobulbar blood vessels: the ophthalmic, the central retinal, and the short posterior ciliary arteries. In this review, we discuss CDI use for the assessment of retinal diseases classified into the following: vascular diseases, degenerations, dystrophies, and detachment. The retinal vascular diseases that have been investigated by CDI include diabetic retinopathy, retinal vein occlusions, retinal artery occlusions, ocular ischemic conditions, and retinopathy of prematurity. Degenerations and dystrophies included in this review are age-related macular degeneration, myopia, and retinitis pigmentosa. CDI has been used for the differential diagnosis of retinal detachment, as well as the evaluation of retrobulbar circulation in this condition. CDI is valuable for research and is a potentially useful diagnostic tool in the clinical setting.
Feasibility study: real-time 3-D ultrasound imaging of the brain.
Smith, Stephen W; Chu, Kengyeh; Idriss, Salim F; Ivancevich, Nikolas M; Light, Edward D; Wolf, Patrick D
2004-10-01
We tested the feasibility of real-time, 3-D ultrasound (US) imaging in the brain. The 3-D scanner uses a matrix phased-array transducer of 512 transmit channels and 256 receive channels operating at 2.5 MHz with a 15-mm diameter footprint. The real-time system scans a 65 degrees pyramid, producing up to 30 volumetric scans per second, and features up to five image planes as well as 3-D rendering, 3-D pulsed-wave and color Doppler. In a human subject, the real-time 3-D scans produced simultaneous transcranial horizontal (axial), coronal and sagittal image planes and real-time volume-rendered images of the gross anatomy of the brain. In a transcranial sheep model, we obtained real-time 3-D color flow Doppler scans and perfusion images using bolus injection of contrast agents into the internal carotid artery.
Della Pepa, Giuseppe Maria; Sabatino, Giovanni; Sturiale, Carmelo Lucio; Marchese, Enrico; Puca, Alfredo; Olivi, Alessandro; Albanese, Alessio
2018-04-01
In the surgical treatment of spinal dural arteriovenous fistulas (DAVFs), intraoperative definition of anatomic characteristics of the DAVF and identification of the fistulous point is mandatory to effectively exclude the DAVF. Intraoperative ultrasound and contrast-enhanced ultrasound integrated with color Doppler ultrasound was applied in the surgical setting for a cervical DAVF to identify the fistulous point and evaluate correct occlusion of the fistula. Integration of intraoperative ultrasound and contrast-enhanced ultrasound is a simple, cost-effective technique that provides an opportunity for real-time dynamic visualization of DAVF vascular patterns, identification of the fistulous point, and assessment of correct exclusion. Compared with other intraoperative tools, such as indocyanine green videoangiography, it allows the surgeon to visualize hidden anatomic and vascular structures, minimizing surgical manipulation and guiding the surgeon during resection. Copyright © 2018 Elsevier Inc. All rights reserved.
A conflict-based model of color categorical perception: evidence from a priming study.
Hu, Zhonghua; Hanley, J Richard; Zhang, Ruiling; Liu, Qiang; Roberson, Debi
2014-10-01
Categorical perception (CP) of color manifests as faster or more accurate discrimination of two shades of color that straddle a category boundary (e.g., one blue and one green) than of two shades from within the same category (e.g., two different shades of green), even when the differences between the pairs of colors are equated according to some objective metric. The results of two experiments provide new evidence for a conflict-based account of this effect, in which CP is caused by competition between visual and verbal/categorical codes on within-category trials. According to this view, conflict arises because the verbal code indicates that the two colors are the same, whereas the visual code indicates that they are different. In Experiment 1, two shades from the same color category were discriminated significantly faster when the previous trial also comprised a pair of within-category colors than when the previous trial comprised a pair from two different color categories. Under the former circumstances, the CP effect disappeared. According to the conflict-based model, response conflict between visual and categorical codes during discrimination of within-category pairs produced an adjustment of cognitive control that reduced the weight given to the categorical code relative to the visual code on the subsequent trial. Consequently, responses on within-category trials were facilitated, and CP effects were reduced. The effectiveness of this conflict-based account was evaluated in comparison with an alternative view that CP reflects temporary warping of perceptual space at the boundaries between color categories.
Color and Grey Scale in Sonar Displays
NASA Technical Reports Server (NTRS)
Kraiss, K. F.; Kuettelwesch, K. H.
1984-01-01
In spite of numerous publications 1 it is still rather unclear, whether color is of any help in sonar displays. The work presented here deals with a particular type of sonar data, i.e., LOFAR-grams (low frequency analysing and recording) where acoustic sensor data are continuously written as a time-frequency plot. The question to be answered quantitatively is, whether color coding does improve target detection when compared with a grey scale code. The data show significant differences in receiver-operating characteristics performance for the selected codes. In addition it turned out, that the background noise level affects the performance dramatically for some color codes, while others remain stable or even improve. Generally valid rules are presented on how to generate useful color scales for this particular application.
Anthropomorphic cardiac ultrasound phantom.
Smith, S W; Rinaldi, J E
1989-10-01
A new phantom is described which simulates the human cardiac anatomy for applications in ultrasound imaging, ultrasound Doppler, and color-flow Doppler imaging. The phantom consists of a polymer left ventricle which includes a prosthetic mitral and aortic valve and is connected to a mock circulatory loop. Aerated tap water serves as a blood simulating fluid and ultrasound contrast medium within the circulatory loop. The left ventricle is housed in a Lexan ultrasound visualization chamber which includes ultrasound viewing ports and acoustic absorbers. A piston pump connected to the visualization chamber by a single port pumps degassed water within the chamber which in turn pumps the left ventricle. Real-time ultrasound images and Doppler studies measure flow patterns through the valves and within the left ventricle.
Three-dimensional high-definition flow in the diagnosis of placental lakes.
Inubashiri, Eisuke; Deguchi, Keizou; Abe, Kiyotaka; Saitou, Atushi; Watanabe, Yukio; Akutagawa, Noriyuki; Kuroki, Katumaru; Sugawara, Masaki; Maeda, Nobuhiko
2014-10-01
Placental lakes are sonolucent areas often found in the normal placenta. Most of them are asymptomatic. They are sometimes related to placenta accreta or intrauterine fetal growth restriction, among other conditions. Although Doppler sonography is useful for evaluating noxious placental lakes, it is not easy to adapt Doppler studies to conventional two-dimensional color Doppler sonography because of the low-velocity blood flow and high vascularity in the placenta. Here, we demonstrate how three-dimensional high-definition imaging of flow provides a novel visual depiction of placental lakes, which helps substantially with the differential diagnosis. As far as we know, there have been no previous reports of observation of placental lakes using three-dimensional high-definition imaging of flow.
Kim, Bum Joon; Kim, Yong-Hwan; Kim, Yeon-Jung; Ahn, Sung Ho; Lee, Deok Hee; Kwon, Sun U; Kim, Sang Joon; Kim, Jong S; Kang, Dong-Wha
2014-09-01
Diffusion-weighted image fluid-attenuated inversion recovery (FLAIR) mismatch has been considered to represent ischemic lesion age. However, the inter-rater agreement of diffusion-weighted image FLAIR mismatch is low. We hypothesized that color-coded images would increase its inter-rater agreement. Patients with ischemic stroke <24 hours of a clear onset were retrospectively studied. FLAIR signal change was rated as negative, subtle, or obvious on conventional and color-coded FLAIR images based on visual inspection. Inter-rater agreement was evaluated using κ and percent agreement. The predictive value of diffusion-weighted image FLAIR mismatch for identification of patients <4.5 hours of symptom onset was evaluated. One hundred and thirteen patients were enrolled. The inter-rater agreement of FLAIR signal change improved from 69.9% (k=0.538) with conventional images to 85.8% (k=0.754) with color-coded images (P=0.004). Discrepantly rated patients on conventional, but not on color-coded images, had a higher prevalence of cardioembolic stroke (P=0.02) and cortical infarction (P=0.04). The positive predictive value for patients <4.5 hours of onset was 85.3% and 71.9% with conventional and 95.7% and 82.1% with color-coded images, by each rater. Color-coded FLAIR images increased the inter-rater agreement of diffusion-weighted image FLAIR recovery mismatch and may ultimately help identify unknown-onset stroke patients appropriate for thrombolysis. © 2014 American Heart Association, Inc.
Color inference in visual communication: the meaning of colors in recycling.
Schloss, Karen B; Lessard, Laurent; Walmsley, Charlotte S; Foley, Kathleen
2018-01-01
People interpret abstract meanings from colors, which makes color a useful perceptual feature for visual communication. This process is complicated, however, because there is seldom a one-to-one correspondence between colors and meanings. One color can be associated with many different concepts (one-to-many mapping) and many colors can be associated with the same concept (many-to-one mapping). We propose that to interpret color-coding systems, people perform assignment inference to determine how colors map onto concepts. We studied assignment inference in the domain of recycling. Participants saw images of colored but unlabeled bins and were asked to indicate which bins they would use to discard different kinds of recyclables and trash. In Experiment 1, we tested two hypotheses for how people perform assignment inference. The local assignment hypothesis predicts that people simply match objects with their most strongly associated color. The global assignment hypothesis predicts that people also account for the association strengths between all other objects and colors within the scope of the color-coding system. Participants discarded objects in bins that optimized the color-object associations of the entire set, which is consistent with the global assignment hypothesis. This sometimes resulted in discarding objects in bins whose colors were weakly associated with the object, even when there was a stronger associated option available. In Experiment 2, we tested different methods for encoding color-coding systems and found that people were better at assignment inference when color sets simultaneously maximized the association strength between assigned color-object parings while minimizing associations between unassigned pairings. Our study provides an approach for designing intuitive color-coding systems that facilitate communication through visual media such as graphs, maps, signs, and artifacts.
NASA Technical Reports Server (NTRS)
Farias, C. A.; Rodriguez, L.; Garcia, M. J.; Sun, J. P.; Klein, A. L.; Thomas, J. D.
1999-01-01
The objective of this study was to determine the utility of Doppler tissue echocardiography in the evaluation of diastolic filling and in discriminating between normal subjects and those with various stages of diastolic dysfunction. We measured myocardial velocities in 51 patients with various stages of diastolic dysfunction and in 27 normal volunteers. The discriminating power of each of the standard Doppler indexes of left ventricular filling, pulmonary venous flow, and myocardial velocities was determined with the use of Spearman rank correlation and analysis of variance F statistics. Early diastolic myocardial velocity (E(m)) was higher in normal subjects (16.0 +/- 3.8 cm/s) than in patients with either delayed relaxation (n = 15, 7.5 +/- 2.2 cm/s), pseudonormal filling (n = 26, 7.6 +/- 2.3 cm/s), or restrictive filling (n = 10, 7.4 +/- 2.4 cm/s, P <.0001). E(m ) was the best single discriminator between control subjects and patients with diastolic dysfunction (P =.7, F = 64.5). Myocardial velocities assessed by Doppler tissue echocardiography are useful in differentiating patients with normal from those with abnormal diastolic function. Myocardial velocity remains reduced even in those stages of diastolic dysfunction characterized by increased preload compensation.
Transversal Clifford gates on folded surface codes
Moussa, Jonathan E.
2016-10-12
Surface and color codes are two forms of topological quantum error correction in two spatial dimensions with complementary properties. Surface codes have lower-depth error detection circuits and well-developed decoders to interpret and correct errors, while color codes have transversal Clifford gates and better code efficiency in the number of physical qubits needed to achieve a given code distance. A formal equivalence exists between color codes and folded surface codes, but it does not guarantee the transferability of any of these favorable properties. However, the equivalence does imply the existence of constant-depth circuit implementations of logical Clifford gates on folded surfacemore » codes. We achieve and improve this result by constructing two families of folded surface codes with transversal Clifford gates. This construction is presented generally for qudits of any dimension. Lastly, the specific application of these codes to universal quantum computation based on qubit fusion is also discussed.« less
Theoretical colours for F and G dwarf stars.
NASA Technical Reports Server (NTRS)
Bell, R. A.
1971-01-01
Synthetic spectra have been computed for F and G dwarf stars, using a number of values of chemical abundance, Doppler broadening velocity, and damping constant. Metal abundances for a number of such stars have been obtained using computed and observed m(sub 1) and 40-52 colors. These abundances are in good agreement with spectroscopically determined ones. The c(sub 1) colors of such stars with exactly known trigonometric parallaxes have been used in order to determine how accurately absolute magnitudes can be predicted from the colors. Generally reasonable agreement can be obtained between observed and predicted absolute magnitudes for certain of these stars. The effects of interstellar reddening on the colors of the models are examined.
Ke, Yifeng; Hao, Rui; He, Yanjin; Tam, Eric S; Li, Xiaorong
2014-05-01
To evaluate color Doppler imaging (CDI) as the primary imaging modality in the diagnosis of pediatric orbital capillary hemangioma. This is a retrospective study of 36 consecutive cases of orbital capillary hemangiomas between January 2006 and July 2011. Data on demographic details, clinical findings, gray-scale ultrasonography, CDI characteristics, treatment, and follow-up period were reviewed. The mean age of onset was 7 weeks. Twenty-nine (81%) lesions presented as eyelid masses, whereas seven (19%) presented as exophthalmos. Nineteen (53%) tumors were located on the upper eyelid, seven (19%) on the lower eyelid, six (17%) in the medial canthus, and one on both upper and lower eyelids. Ultrasonography depicted a heterogeneous, well-defined, irregular tumor with a low or moderate echogenicity. All lesions presented with abundant color blood flow on CDI. The intralesional blood flow had a mean peak systolic velocity of 37.5 ± 24.5 cm/second, and a mean resistance index of 0.69 ± 0.16, representing a shift in the pulse Doppler toward high velocity and high resistance. After a single intratumoral injection of betamethasone, 18 cases (50%) resolved. Additionally, 15 (42%) and four (11%) cases resolved after two injections and three injections, respectively. Only three (8%) masses persisted after three injections within the follow-up period. The blood flow characteristics of CDI play a vital role in the differentiation of orbital capillary hemangiomas from other orbital lesions. The availability and lack of adverse effects of CDI enable its utilization in the early clinical diagnosis of pediatric orbital capillary hemangioma. Copyright © 2014. Published by Elsevier B.V.
Human Colors-The Rainbow Garden of Pathology: What Gives Normal and Pathologic Tissues Their Color?
Piña-Oviedo, Sergio; Ortiz-Hidalgo, Carlos; Ayala, Alberto G
2017-03-01
- Colors are important to all living organisms because they are crucial for camouflage and protection, metabolism, sexual behavior, and communication. Human organs obviously have color, but the underlying biologic processes that dictate the specific colors of organs and tissues are not completely understood. A literature search on the determinants of color in human organs yielded scant information. - To address 2 specific questions: (1) why do human organs have color, and (2) what gives normal and pathologic tissues their distinctive colors? - Endogenous colors are the result of complex biochemical reactions that produce biologic pigments: red-brown cytochromes and porphyrins (blood, liver, spleen, kidneys, striated muscle), brown-black melanins (skin, appendages, brain nuclei), dark-brown lipochromes (aging organs), and colors that result from tissue structure (tendons, aponeurosis, muscles). Yellow-orange carotenes that deposit in lipid-rich tissues are only produced by plants and are acquired from the diet. However, there is lack of information about the cause of color in other organs, such as the gray and white matter, neuroendocrine organs, and white tissues (epithelia, soft tissues). Neoplastic tissues usually retain the color of their nonneoplastic counterpart. - Most available information on the function of pigments comes from studies in plants, microorganisms, cephalopods, and vertebrates, not humans. Biologic pigments have antioxidant and cytoprotective properties and should be considered as potential future therapies for disease and cancer. We discuss the bioproducts that may be responsible for organ coloration and invite pathologists and pathology residents to look at a "routine grossing day" with a different perspective.
Redundant Coding in Visual Search Displays: Effects of Shape and Colour.
1997-02-01
results for refining color selection algorithms and for color coding in situations where the gamut of available colors is limited. In a secondary set of analyses, we note large performance differences as a function of target shape.
Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui
2013-12-01
The rapid advancement of high-throughput tools for quantitative measurement of proteins has demonstrated the potential for the identification of proteins associated with cancer. However, the quantitative results on cancer tissue specimens are usually confounded by tissue heterogeneity, e.g. regions with cancer usually have significantly higher epithelium content yet lower stromal content. It is therefore necessary to develop a tool to facilitate the interpretation of the results of protein measurements in tissue specimens. Epithelial cell adhesion molecule (EpCAM) and cathepsin L (CTSL) are two epithelial proteins whose expressions in normal and tumorous prostate tissues were confirmed by measuring staining intensity with immunohistochemical staining (IHC). The expressions of these proteins were measured by ELISA in protein extracts from OCT embedded frozen prostate tissues. To eliminate the influence of tissue heterogeneity on epithelial protein quantification measured by ELISA, a color-based segmentation method was developed in-house for estimation of epithelium content using H&E histology slides from the same prostate tissues and the estimated epithelium percentage was used to normalize the ELISA results. The epithelium contents of the same slides were also estimated by a pathologist and used to normalize the ELISA results. The computer based results were compared with the pathologist's reading. We found that both EpCAM and CTSL levels, measured by ELISA assays itself, were greatly affected by epithelium content in the tissue specimens. Without adjusting for epithelium percentage, both EpCAM and CTSL levels appeared significantly higher in tumor tissues than normal tissues with a p value less than 0.001. However, after normalization by the epithelium percentage, ELISA measurements of both EpCAM and CTSL were in agreement with IHC staining results, showing a significant increase only in EpCAM with no difference in CTSL expression in cancer tissues. These results were obtained with normalization by both the computer estimated and pathologist estimated epithelium percentage. Our results show that estimation of tissue epithelium percentage using our color-based segmentation method correlates well with pathologists' estimation of tissue epithelium percentages. The epithelium contents estimated by color-based segmentation may be useful in immuno-based analysis or clinical proteomic analysis of tumor proteins. The codes used for epithelium estimation as well as the micrographs with estimated epithelium content are available online.
Cao, Dainan; Gong, Shiping; Yang, Jiangbo; Li, Weiye; Ge, Yan; Wei, Yufeng
2018-03-01
Animal coloration primarily depends on the presence of pigments and the mixing ratio of eumelanin and pheomelanin. The color of red-eared slider's carapace varies with age, from an olive green to a yellow green, and then to a yellow brown in juveniles, generally. The purpose of the present study was to investigate whether this color change is related to the difference in melanin expression. Melanin deposition levels were examined in the carapace, skin, eye and muscle of the three color-types using hematoxylin and eosin staining. Moreover, the full-length coding sequence (CDS) of red-eared slider turtle melanin biosynthesis regulatory genes TYR, TYRP1, MITF and SLC24A5 were cloned, sequenced and quantitatively analyzed. Both histological view of melanin deposition and quantitative real-time PCR test of melanin-regulated gene expressions showed that there are significant differences among different tissues of red-eared slider, but no significant difference among different color-types, indicating that melanin deposition is not associated with ontogenetic color change in the carapace of red-eared slider. This study initially explore the melanin deposition and the mRNA expression of melanin biosynthesis regulatory genes in red-eared slider, which serve as a foundation for further insight into the pigmentation patterns and the mechanism of body color change in turtles. Copyright © 2017 Elsevier Inc. All rights reserved.
Apparatus for Teaching Physics.
ERIC Educational Resources Information Center
Minnix, Richard B.; Carpenter, D. Rae, Jr., Eds.
1982-01-01
Thirteen demonstrations using a capacitor-start induction motor fitted with an aluminum disk are described. Demonstrations illustrate principles from mechanics, fluids (Bernoulli's principle), waves (chladni patterns and doppler effect), magnetism, electricity, and light (mechanical color mixing). In addition, the instrument can measure friction…
Visual search asymmetries within color-coded and intensity-coded displays.
Yamani, Yusuke; McCarley, Jason S
2010-06-01
Color and intensity coding provide perceptual cues to segregate categories of objects within a visual display, allowing operators to search more efficiently for needed information. Even within a perceptually distinct subset of display elements, however, it may often be useful to prioritize items representing urgent or task-critical information. The design of symbology to produce search asymmetries (Treisman & Souther, 1985) offers a potential technique for doing this, but it is not obvious from existing models of search that an asymmetry observed in the absence of extraneous visual stimuli will persist within a complex color- or intensity-coded display. To address this issue, in the current study we measured the strength of a visual search asymmetry within displays containing color- or intensity-coded extraneous items. The asymmetry persisted strongly in the presence of extraneous items that were drawn in a different color (Experiment 1) or a lower contrast (Experiment 2) than the search-relevant items, with the targets favored by the search asymmetry producing highly efficient search. The asymmetry was attenuated but not eliminated when extraneous items were drawn in a higher contrast than search-relevant items (Experiment 3). Results imply that the coding of symbology to exploit visual search asymmetries can facilitate visual search for high-priority items even within color- or intensity-coded displays. PsycINFO Database Record (c) 2010 APA, all rights reserved.
African Doppler Surveys (ADOS).
1983-06-01
UP TO 31 MARCH 1983 MAILING DATE: 11 APRIL 1983 SURVEY STATUS DATA STATUSDOPPLER STATION L1 OR1ATION - ______(hte 1,(Whether data dis- GEOD . TIES...SURVEY STATUS DTA STATUS DOPPLER STATION INFORMATION (Whet~her data dia- GEOD . TIES patched to...data dis- GEOD . TIES patched to COUNThY STATION NAME APPROXIMAT OPPLER designated CODE AND ADOS NO. SZION ()outh Comp. Center) COORDINATES fin- Yes
Ataalla, Walid M; Ziada, Dina H; Gaber, Rania; Ossman, Ahmed; Bayomy, Suzan; Elemary, Berihan R
2016-01-01
The aim of this study was to assess total bile acid (TBA) levels and its impact on systolic and diastolic functions in fetuses of mothers with intrahepatic cholestasis of pregnancy (ICP) using tissue Doppler imaging (TDI), and to explore the correlation between TBA levels and fetal cardiac function. The study employed 98 pregnant women with ICP who were divided into two groups according to their bile acid levels. Fifty pregnant women without ICP represented the control group. Significant differences in the myocardial tissue velocities of both mitral and tricuspid valves were found between the fetuses of mothers with ICP and TBA levels of <40 mmol/L and the control group, versus fetuses of mothers with ICP and TBA levels >40 mmol/L. There was a significant increase in neonatal respiratory distress, meconium staining and neonatal TBAs in group II compared to the control group and group I. There was a correlation between maternal TBA levels and preterm delivery, APGAR scores and neonatal TBA levels at birth. There was also a positive correlation between maternal TBA and fetal myocardial tissue velocities of both mitral and tricuspid, and fetal diastolic myocardial tissue Doppler velocities. ICP is a very serious condition especially when maternal TBA levels are >40 mmol/L. Fetal echocardiography with tissue Doppler is a useful tool for fetal assessment in patients with ICP. It could be an indication of induction of labor in cases of ICP and bile acid levels ≥40 mol/L. Neonatal echocardiography is mandatory for follow-up and management of these neonates.
Dutra, E C; Koch, J A; Presura, R; Angermeier, W A; Darling, T; Haque, S; Mancini, R C; Covington, A M
2016-11-01
Spectroscopic techniques in the visible range are often used in plasma experiments to measure B-field induced Zeeman splitting, electron densities via Stark broadening, and temperatures from Doppler broadening. However, when electron densities and temperatures are sufficiently high, the broadening of the Stark and Doppler components can dominate the emission spectra and obscure the Zeeman component. In this research, we are developing a time-resolved multi-axial technique for measuring the Zeeman, Stark, and Doppler broadened line emission of dense magnetized plasmas for Z-pinch and Dense Plasma Focus (DPF) accelerators. The line emission is used to calculate the electron densities, temperatures, and B-fields. In parallel, we are developing a line-shape modeling code that incorporates the broadening effects due to Stark, Doppler, and Zeeman effects for dense magnetized plasma. This manuscript presents the details of the experimental setup and line shape code, along with the results obtained from an Al iii doublet at the University of Nevada, Reno at Nevada Terawatt Facility. Future tests are planned to further evaluate the technique and modeling on other material wire array, gas puff, and DPF platforms.
Trellis coded multilevel DPSK system with doppler correction for mobile satellite channels
NASA Technical Reports Server (NTRS)
Divsalar, Dariush (Inventor); Simon, Marvin K. (Inventor)
1991-01-01
A trellis coded multilevel differential phase shift keyed mobile communication system. The system of the present invention includes a trellis encoder for translating input signals into trellis codes; a differential encoder for differentially encoding the trellis coded signals; a transmitter for transmitting the differentially encoded trellis coded signals; a receiver for receiving the transmitted signals; a differential demodulator for demodulating the received differentially encoded trellis coded signals; and a trellis decoder for decoding the differentially demodulated signals.
Sonographic evaluation of thyroiditis with color flow study.
Sultana, N; Rima, S; Rahman, S; Azad, S A; Karim, M E; Shawkat, S; Ahsan, M; Kamal, M M; Begum, M
2014-01-01
This cross sectional study was carried out in the Department of Radiology and Imaging, Bangabandhu Sheikh Mujib Medical University, Bangladesh in collaboration with the Department of Endocrinology and Department of Histopathology of the same hospital during the period of March 2007 to February 2008 to determine efficacy of ultrasonogram in the evaluation of thyroiditis and to compare its results with color flow Doppler study. For this purpose, a total of 50 patients having clinical suspicion of thyroiditis were enrolled in this study. Ultrasound and color Doppler were done in all these patients. Then all patients underwent for FNAC in the Histopathology department. Correlation between sonographic diagnosis and histopathological diagnosis were observed. Out of these 50 patients 10(20%) were male and 40 (80%) were female with age ranging from 12 to 50 years, highest between 21 to 30 years. The mean age of the patients was 30.42±9.57 years. On unltrasonographic findings of thyroid gland 42.0% patients had regular and 58.0% had irregular margin. Seventy percent had fibrosis, 14.0% had feature of necrosis, 48.0% had lymphadenopathy. Out of all patients 6.0% had normal echogenic feature, 16.0% had increased and 78.0% decreased echogeneic feature. Twelve percent (12.0%) patients had homogeneous and 88.0% had heterogeneous pattern of echogenecity. Thirty eight percent (38%) patients had focal nodules. Sixty percent (60.0%) patients had focal swelling and 40.0% had diffuse swelling. On color flow Doppler 28.0% had normal, 38.0% had increased and 34.0% decreased vascular flow pattern. USG reports revealed that 48.0% had thyromegaly, 36.0% had thyroid nodule, 10.0% had multinodular goiter and 6.0% had thyroid abscess. FNAC diagnosis revealed that 34.0% patients had Hashimoto's thyroiditis, 24.0% had lymphocytic thyroiditis, 18.0% had granulomatous thyroiditis, 6.0% had abscess, 8.0% had goitre and 10.0% nonspecific. USG and CFD are recommended modalities for the diagnosis of thyroiditis as these cost-effective and non invasive procedures.
Guffanti, Marianne C.; Miller, Thomas
2013-01-01
An alert-level system for communicating volcano hazard information to the aviation industry was devised by the Alaska Volcano Observatory (AVO) during the 1989–1990 eruption of Redoubt Volcano. The system uses a simple, color-coded ranking that focuses on volcanic ash emissions: Green—normal background; Yellow—signs of unrest; Orange—precursory unrest or minor ash eruption; Red—major ash eruption imminent or underway. The color code has been successfully applied on a regional scale in Alaska for a sustained period. During 2002–2011, elevated color codes were assigned by AVO to 13 volcanoes, eight of which erupted; for that decade, one or more Alaskan volcanoes were at Yellow on 67 % of days and at Orange or Red on 12 % of days. As evidence of its utility, the color code system is integrated into procedures of agencies responsible for air-traffic management and aviation meteorology in Alaska. Furthermore, it is endorsed as a key part of globally coordinated protocols established by the International Civil Aviation Organization to provide warnings of ash hazards to aviation worldwide. The color code and accompanying structured message (called a Volcano Observatory Notice for Aviation) comprise an effective early-warning message system according to the United Nations International Strategy for Disaster Reduction. The aviation color code system currently is used in the United States, Russia, New Zealand, Iceland, and partially in the Philippines, Papua New Guinea, and Indonesia. Although there are some barriers to implementation, with continued education and outreach to Volcano Observatories worldwide, greater use of the aviation color code system is achievable.
Guffanti, Marianne; Miller, Thomas P.
2013-01-01
An alert-level system for communicating volcano hazard information to the aviation industry was devised by the Alaska Volcano Observatory (AVO) during the 1989–1990 eruption of Redoubt Volcano. The system uses a simple, color-coded ranking that focuses on volcanic ash emissions: Green—normal background; Yellow—signs of unrest; Orange—precursory unrest or minor ash eruption; Red—major ash eruption imminent or underway. The color code has been successfully applied on a regional scale in Alaska for a sustained period. During 2002–2011, elevated color codes were assigned by AVO to 13 volcanoes, eight of which erupted; for that decade, one or more Alaskan volcanoes were at Yellow on 67 % of days and at Orange or Red on 12 % of days. As evidence of its utility, the color code system is integrated into procedures of agencies responsible for air-traffic management and aviation meteorology in Alaska. Furthermore, it is endorsed as a key part of globally coordinated protocols established by the International Civil Aviation Organization to provide warnings of ash hazards to aviation worldwide. The color code and accompanying structured message (called a Volcano Observatory Notice for Aviation) comprise an effective early-warning message system according to the United Nations International Strategy for Disaster Reduction. The aviation color code system currently is used in the United States, Russia, New Zealand, Iceland, and partially in the Philippines, Papua New Guinea, and Indonesia. Although there are some barriers to implementation, with continued education and outreach to Volcano Observatories worldwide, greater use of the aviation color code system is achievable.
System for Processing Coded OFDM Under Doppler and Fading
NASA Technical Reports Server (NTRS)
Tsou, Haiping; Darden, Scott; Lee, Dennis; Yan, Tsun-Yee
2005-01-01
An advanced communication system has been proposed for transmitting and receiving coded digital data conveyed as a form of quadrature amplitude modulation (QAM) on orthogonal frequency-division multiplexing (OFDM) signals in the presence of such adverse propagation-channel effects as large dynamic Doppler shifts and frequency-selective multipath fading. Such adverse channel effects are typical of data communications between mobile units or between mobile and stationary units (e.g., telemetric transmissions from aircraft to ground stations). The proposed system incorporates novel signal processing techniques intended to reduce the losses associated with adverse channel effects while maintaining compatibility with the high-speed physical layer specifications defined for wireless local area networks (LANs) as the standard 802.11a of the Institute of Electrical and Electronics Engineers (IEEE 802.11a). OFDM is a multi-carrier modulation technique that is widely used for wireless transmission of data in LANs and in metropolitan area networks (MANs). OFDM has been adopted in IEEE 802.11a and some other industry standards because it affords robust performance under frequency-selective fading. However, its intrinsic frequency-diversity feature is highly sensitive to synchronization errors; this sensitivity poses a challenge to preserve coherence between the component subcarriers of an OFDM system in order to avoid intercarrier interference in the presence of large dynamic Doppler shifts as well as frequency-selective fading. As a result, heretofore, the use of OFDM has been limited primarily to applications involving small or zero Doppler shifts. The proposed system includes a digital coherent OFDM communication system that would utilize enhanced 802.1la-compatible signal-processing algorithms to overcome effects of frequency-selective fading and large dynamic Doppler shifts. The overall transceiver design would implement a two-frequency-channel architecture (see figure) that would afford frequency diversity for reducing the adverse effects of multipath fading. By using parallel concatenated convolutional codes (also known as Turbo codes) across the dual-channel and advanced OFDM signal processing within each channel, the proposed system is intended to achieve at least an order of magnitude improvement in received signal-to-noise ratio under adverse channel effects while preserving spectral efficiency.
Garadah, Taysir; Kassab, Salah; Gabani, Saleh; Abu-Taleb, Ahmed; Abdelatif, Ahmed; Asef, Aysha; Shoroqi, Issa; Jamsheer, Anwer
2011-01-01
Background Hypertensive crisis (HC) is a common medical emergency associated with acute rise in arterial blood pressure that leads to end-organ damage (EOD). Therefore, it is imperative to find markers that may help in the prediction of EOD in acute hypertensive crisis. Aim To assess the clinical presentations on admission; echocardiographic changes of pulsed and tissue Doppler changes in EOD patients compared with no EOD; and the risk of developing end organ damage for clinical and biochemical variables in hypertension crisis. Material and Methods The data of 241 patients with hypertensive crisis with systolic blood pressure (SBP) of >180 mmHg or diastolic blood pressure (DBP) >120 mmHg were extracted from patients files. Patients divided into hypertensive emergency (HE) with EOD, n = 62 and hypertensive urgency (HU) without EOD, n = 179. LV hypertrophy on ECG, echo parameters for wall thickness, left Ventricular mass index (LVMI), Body mass index (BMI), pulse Doppler ratio of early filling velocity E wave to late A wave (E/A) and ratio of E wave velocity to tissue Doppler Em to E wave (E/Em) were evaluated. Serum creatinine, hemoglobin, age, gender, body mass Index (BMI), history of diabetes mellitus, smoking, hypertension, stroke and hyperlipidemia were recorded. Multiple logistic regression analysis was applied for risk prediction of end organ damage of clinical variables. Results Patients with HE compared with HU were significantly older, with a significantly higher SBP on admission, high BMI and LVMI. Further there were significantly higher E/A ratio on Doppler echo and higher E/Em ratio on tissue Doppler echocardiogram. Multiple regression analysis with adjustment for age and sex shows positive predictive value with odds ratio of SBP on admission >220 mmHg of 1.98, serum creatinine > 120 µg/L of 1.43, older age > 60 year of 1.304, obesity (BMI ≥ 30) of 1.9, male gender of 2.26 and left ventricle hypertrophy on ECG of 1.92. The hemoglobin level, history of smoking, hyperlipidemia and DM were with no significant predictive value. The pulsed Doppler E/A ratio was ≥1.6, E/Em > 15, LVMI > 125 gm/m2 in patients with EOD compared with those without. Conclusion In patients presented with hypertensive crisis, the echo indices of E/A ratio and E/Em ratio of tissue Doppler are significantly higher in patients with hypertensive emergency compared to hypertensive urgency. The left ventricle hypertrophy on ECG, high LV mass index of >125 gm/m2, BMI > 30, old age > 60 year, male gender and history of hypertension and stroke were positive predictors of poor outcome and end organ damage. PMID:26949338
Garadah, Taysir; Kassab, Salah; Gabani, Saleh; Abu-Taleb, Ahmed; Abdelatif, Ahmed; Asef, Aysha; Shoroqi, Issa; Jamsheer, Anwer
2011-01-01
Hypertensive crisis (HC) is a common medical emergency associated with acute rise in arterial blood pressure that leads to end-organ damage (EOD). Therefore, it is imperative to find markers that may help in the prediction of EOD in acute hypertensive crisis. To assess the clinical presentations on admission; echocardiographic changes of pulsed and tissue Doppler changes in EOD patients compared with no EOD; and the risk of developing end organ damage for clinical and biochemical variables in hypertension crisis. The data of 241 patients with hypertensive crisis with systolic blood pressure (SBP) of >180 mmHg or diastolic blood pressure (DBP) >120 mmHg were extracted from patients files. Patients divided into hypertensive emergency (HE) with EOD, n = 62 and hypertensive urgency (HU) without EOD, n = 179. LV hypertrophy on ECG, echo parameters for wall thickness, left Ventricular mass index (LVMI), Body mass index (BMI), pulse Doppler ratio of early filling velocity E wave to late A wave (E/A) and ratio of E wave velocity to tissue Doppler Em to E wave (E/Em) were evaluated. Serum creatinine, hemoglobin, age, gender, body mass Index (BMI), history of diabetes mellitus, smoking, hypertension, stroke and hyperlipidemia were recorded. Multiple logistic regression analysis was applied for risk prediction of end organ damage of clinical variables. Patients with HE compared with HU were significantly older, with a significantly higher SBP on admission, high BMI and LVMI. Further there were significantly higher E/A ratio on Doppler echo and higher E/Em ratio on tissue Doppler echocardiogram. Multiple regression analysis with adjustment for age and sex shows positive predictive value with odds ratio of SBP on admission >220 mmHg of 1.98, serum creatinine > 120 µg/L of 1.43, older age > 60 year of 1.304, obesity (BMI ≥ 30) of 1.9, male gender of 2.26 and left ventricle hypertrophy on ECG of 1.92. The hemoglobin level, history of smoking, hyperlipidemia and DM were with no significant predictive value. The pulsed Doppler E/A ratio was ≥1.6, E/Em > 15, LVMI > 125 gm/m(2) in patients with EOD compared with those without. In patients presented with hypertensive crisis, the echo indices of E/A ratio and E/Em ratio of tissue Doppler are significantly higher in patients with hypertensive emergency compared to hypertensive urgency. The left ventricle hypertrophy on ECG, high LV mass index of >125 gm/m(2), BMI > 30, old age > 60 year, male gender and history of hypertension and stroke were positive predictors of poor outcome and end organ damage.
Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U
2017-04-01
Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p < 0.001), in TAMx of 53.2% (p < 0.001) and 38.3% (p = 0.002), and in TAMn of 84.4% (p < 0.001) and 68.2% (p < 0.001). Semiquantitative power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.
Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen
2011-01-01
We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography. PMID:21941690
Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen
2011-01-01
We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.
Sato, Takahiro; Yamazaki, Katsu; Kimura, Mutsuumi; Toyota, Jouji; Karino, Yoshiyasu
2014-01-01
Gastric varices that arise secondary to the splenic vein occlusion can result in gastrointestinal hemorrhaging. Endoscopic color Doppler ultrasonography (ECDUS) was performed in 16 patients with gastric varices secondary to splenic vein occlusion. This study retrospectively evaluated the role of ECDUS in the diagnosis of gastric varices secondary to splenic vein occlusion. Thirteen patients had co-existing pancreatic diseases: 8 with chronic pancreatitis, 4 with cancer of the pancreatic body or tail and 1 with severe acute pancreatitis. Of the remaining 3 patients, 1 had myeloproliferative disease, 1 had advanced gastric cancer, and the third had splenic vein occlusion due to an obscure cause. The endoscopic findings of gastric varices were: variceal form (F) classified as enlarged tortuous (F2) in 12 cases and large, coil-shaped (F3) in 4 cases, and positive for erosion or red color sign of the variceal surface in 4 cases and negative in 12 cases. ECDUS color flow images of gastric variceal flow clearly depicted a round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body in all 16 cases. The velocities of F3 type gastric varices were significantly higher than those of the F2 type. The wall thickness of varices positive for erosion or red color sign was significantly less than the negative cases. I conclude that ECDUS color flow images of gastric variceal flow depicted specific findings of gastric varices secondary to splenic vein occlusion at the round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body. PMID:26852679
NASA Technical Reports Server (NTRS)
Pate, T. H.
1982-01-01
Geographic coverage frequency and geographic shot density for a satellite borne Doppler lidar wind velocity measuring system are measured. The equations of motion of the light path on the ground were derived and a computer program devised to compute shot density and coverage frequency by latitude-longitude sections. The equations for the coverage boundaries were derived and a computer program developed to plot these boundaries, thus making it possible, after an application of a map coloring algorithm, to actually see the areas of multiple coverage. A theoretical cross-swath shot density function that gives close approximations in certain cases was also derived. This information should aid in the design of an efficient data-processing system for the Doppler lidar.
Simulated cosmic microwave background maps at 0.5 deg resolution: Basic results
NASA Technical Reports Server (NTRS)
Hinshaw, G.; Bennett, C. L.; Kogut, A.
1995-01-01
We have simulated full-sky maps of the cosmic microwave background (CMB) anisotropy expected from cold dark matter (CDM) models at 0.5 deg and 1.0 deg angular resolution. Statistical properties of the maps are presented as a function of sky coverage, angular resolution, and instrument noise, and the implications of these results for observability of the Doppler peak are discussed. The rms fluctuations in a map are not a particularly robust probe of the existence of a Doppler peak; however, a full correlation analysis can provide reasonable sensitivity. We find that sensitivity to the Doppler peak depends primarily on the fraction of sky covered, and only secondarily on the angular resolution and noise level. Color plates of the simulated maps are presented to illustrate the anisotropies.
Hoffman, Robert M
2016-03-01
Fluorescent proteins are very bright and available in spectrally-distinct colors, enable the imaging of color-coded cancer cells growing in vivo and therefore the distinction of cancer cells with different genetic properties. Non-invasive and intravital imaging of cancer cells with fluorescent proteins allows the visualization of distinct genetic variants of cancer cells down to the cellular level in vivo. Cancer cells with increased or decreased ability to metastasize can be distinguished in vivo. Gene exchange in vivo which enables low metastatic cancer cells to convert to high metastatic can be color-coded imaged in vivo. Cancer stem-like and non-stem cells can be distinguished in vivo by color-coded imaging. These properties also demonstrate the vast superiority of imaging cancer cells in vivo with fluorescent proteins over photon counting of luciferase-labeled cancer cells.
Nelson, John Stuart; Milner, Thomas Edward; Chen, Zhongping
1999-01-01
Optical Doppler tomography permits imaging of fluid flow velocity in highly scattering media. The tomography system combines Doppler velocimetry with high spatial resolution of partially coherent optical interferometry to measure fluid flow velocity at discrete spatial locations. Noninvasive in vivo imaging of blood flow dynamics and tissue structures with high spatial resolutions of the order of 2 to 10 microns is achieved in biological systems. The backscattered interference signals derived from the interferometer may be analyzed either through power spectrum determination to obtain the position and velocity of each particle in the fluid flow sample at each pixel, or the interference spectral density may be analyzed at each frequency in the spectrum to obtain the positions and velocities of the particles in a cross-section to which the interference spectral density corresponds. The realized resolutions of optical Doppler tomography allows noninvasive in vivo imaging of both blood microcirculation and tissue structure surrounding the vessel which has significance for biomedical research and clinical applications.
Connaughton, Veronica M; Amiruddin, Azhani; Clunies-Ross, Karen L; French, Noel; Fox, Allison M
2017-05-01
A major model of the cerebral circuits that underpin arithmetic calculation is the triple-code model of numerical processing. This model proposes that the lateralization of mathematical operations is organized across three circuits: a left-hemispheric dominant verbal code; a bilateral magnitude representation of numbers and a bilateral Arabic number code. This study simultaneously measured the blood flow of both middle cerebral arteries using functional transcranial Doppler ultrasonography to assess hemispheric specialization during the performance of both language and arithmetic tasks. The propositions of the triple-code model were assessed in a non-clinical adult group by measuring cerebral blood flow during the performance of multiplication and subtraction problems. Participants were 17 adults aged between 18-27 years. We obtained laterality indices for each type of mathematical operation and compared these in participants with left-hemispheric language dominance. It was hypothesized that blood flow would lateralize to the left hemisphere during the performance of multiplication operations, but would not lateralize during the performance of subtraction operations. Hemispheric blood flow was significantly left lateralized during the multiplication task, but was not lateralized during the subtraction task. Compared to high spatial resolution neuroimaging techniques previously used to measure cerebral lateralization, functional transcranial Doppler ultrasonography is a cost-effective measure that provides a superior temporal representation of arithmetic cognition. These results provide support for the triple-code model of arithmetic processing and offer complementary evidence that multiplication operations are processed differently in the adult brain compared to subtraction operations. Copyright © 2017 Elsevier B.V. All rights reserved.
Doppler Fourier Domain Optical Coherence Tomography for Label-Free Tissue Angiography
NASA Astrophysics Data System (ADS)
Leitgeb, Rainer A.; Szkulmowski, Maciej; Blatter, Cedric; Wojtkowski, Maciej
Information about tissue perfusion and the vascular structure is certainly most important for assessment of tissue state or personal health and the diagnosis of any pathological conditions. It is therefore of key medical interest to have tools available for both quantitative blood flow assessment as well as qualitative vascular imaging. The strength of optical techniques is the unprecedented level of detail even for small capillary structures or microaneurysms and the possibility to combine different techniques for additional tissue spectroscopy giving insight into tissue metabolism. There is an immediate diagnostic and pharmacological demand for high-resolution, label-free, tissue angiography and flow assessment that in addition allow for precise depth gating of flow information. The most promising candidate is Doppler optical coherence tomography (DOCT) being noncontact, label free, and without employing hazardous radiation. DOCT provides fully quantitative volumetric information about blood flow together with the vascular and structural anatomy. Besides flow quantification, analysis of OCT signal fluctuations allows to contrast moving scatterers in tissue such as red blood cells from static tissue. This allows for non-invasive optical angiography and yields high resolution even for smallest capillaries. Because of the huge potential of DOCT and lable-free optical angiography for diagnosis, the last years saw a rapid increase of publications in this field with many different approaches. The present chapter gives an overview over existing Doppler OCT approaches and angiography techniques. It furthermore discusses limitations and noise issues, and gives examples for angiography in the eye and the skin.
Experimental and computational laser tissue welding using a protein patch.
Small, W; Heredia, N J; Maitland, D J; Eder, D C; Celliers, P M; Da Silva, L B; London, R A; Matthews, D L
1998-01-01
An in vitro study of laser tissue welding mediated with a dye-enhanced protein patch was conducted. Fresh sections of porcine aorta were used for the experiments. Arteriotomies were treated using an indocyanine green dye-enhanced collagen patch activated by an 805-nm continuous-wave fiber-delivered diode laser. Temperature histories of the surface of the weld site were obtained using a hollow glass optical fiber-based two-color infrared thermometer. The experimental effort was complemented by simulations with the LATIS (LAser-TISsue) computer code, which uses coupled Monte Carlo, thermal transport, and mass transport models. Comparison of simulated and experimental thermal data indicated that evaporative cooling clamped the surface temperature of the weld site below 100 °C. For fluences of approximately 200 J/cm2, peak surface temperatures averaged 74°C and acute burst strengths consistently exceeded 0.14×106 dyn/cm (hoop tension). The combination of experimental and simulation results showed that the inclusion of water transport and evaporative losses in the computer code has a significant impact on the thermal distributions and hydration levels throughout the tissue volume. The solid-matrix protein patch provided a means of controllable energy delivery and yielded consistently strong welds. © 1998 Society of Photo-Optical Instrumentation Engineers.
Quantum computing with Majorana fermion codes
NASA Astrophysics Data System (ADS)
Litinski, Daniel; von Oppen, Felix
2018-05-01
We establish a unified framework for Majorana-based fault-tolerant quantum computation with Majorana surface codes and Majorana color codes. All logical Clifford gates are implemented with zero-time overhead. This is done by introducing a protocol for Pauli product measurements with tetrons and hexons which only requires local 4-Majorana parity measurements. An analogous protocol is used in the fault-tolerant setting, where tetrons and hexons are replaced by Majorana surface code patches, and parity measurements are replaced by lattice surgery, still only requiring local few-Majorana parity measurements. To this end, we discuss twist defects in Majorana fermion surface codes and adapt the technique of twist-based lattice surgery to fermionic codes. Moreover, we propose a family of codes that we refer to as Majorana color codes, which are obtained by concatenating Majorana surface codes with small Majorana fermion codes. Majorana surface and color codes can be used to decrease the space overhead and stabilizer weight compared to their bosonic counterparts.
Veyrat, Colette; Larrazet, Fabrice; Pellerin, Denis
2005-10-01
There is renewed interest in isovolumic contraction (IC) in tissue Doppler echocardiography of the myocardial walls, which is revisited in this editorial with new regional velocity data. The aims are to recall traditional background information and to emphasize the need to master the rapidly evolving tissue Doppler procedures for the accurate display of brief IC. IC, a preejectional component of great physiologic interest, is very demanding in terms of ultrasound technology. The onset and end of its motion velocities should be unambiguously defined versus the QRS complex and ejection wall motion. This is a prerequisite for exploiting the new information as guidance toward new therapeutic strategies from a practical viewpoint. However, IC preload dependence should be kept in mind, because of its limited potential for contractility studies. Finally, when only duration measurements are made in the assessment of ventricular dyssynchrony, regional preejectional duration is the pertinent tool to single out the onset of ejection local wall motion.
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii... 29 Labor 5 2011-07-01 2011-07-01 false Safety color code for marking physical hazards. 1910.144 Section 1910.144 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH...
Modified linear predictive coding approach for moving target tracking by Doppler radar
NASA Astrophysics Data System (ADS)
Ding, Yipeng; Lin, Xiaoyi; Sun, Ke-Hui; Xu, Xue-Mei; Liu, Xi-Yao
2016-07-01
Doppler radar is a cost-effective tool for moving target tracking, which can support a large range of civilian and military applications. A modified linear predictive coding (LPC) approach is proposed to increase the target localization accuracy of the Doppler radar. Based on the time-frequency analysis of the received echo, the proposed approach first real-time estimates the noise statistical parameters and constructs an adaptive filter to intelligently suppress the noise interference. Then, a linear predictive model is applied to extend the available data, which can help improve the resolution of the target localization result. Compared with the traditional LPC method, which empirically decides the extension data length, the proposed approach develops an error array to evaluate the prediction accuracy and thus, adjust the optimum extension data length intelligently. Finally, the prediction error array is superimposed with the predictor output to correct the prediction error. A series of experiments are conducted to illustrate the validity and performance of the proposed techniques.
Progressive low-bitrate digital color/monochrome image coding by neuro-fuzzy clustering
NASA Astrophysics Data System (ADS)
Mitra, Sunanda; Meadows, Steven
1997-10-01
Color image coding at low bit rates is an area of research that is just being addressed in recent literature since the problems of storage and transmission of color images are becoming more prominent in many applications. Current trends in image coding exploit the advantage of subband/wavelet decompositions in reducing the complexity in optimal scalar/vector quantizer (SQ/VQ) design. Compression ratios (CRs) of the order of 10:1 to 20:1 with high visual quality have been achieved by using vector quantization of subband decomposed color images in perceptually weighted color spaces. We report the performance of a recently developed adaptive vector quantizer, namely, AFLC-VQ for effective reduction in bit rates while maintaining high visual quality of reconstructed color as well as monochrome images. For 24 bit color images, excellent visual quality is maintained upto a bit rate reduction to approximately 0.48 bpp (for each color plane or monochrome 0.16 bpp, CR 50:1) by using the RGB color space. Further tuning of the AFLC-VQ, and addition of an entropy coder module after the VQ stage results in extremely low bit rates (CR 80:1) for good quality, reconstructed images. Our recent study also reveals that for similar visual quality, RGB color space requires less bits/pixel than either the YIQ, or HIS color space for storing the same information when entropy coding is applied. AFLC-VQ outperforms other standard VQ and adaptive SQ techniques in retaining visual fidelity at similar bit rate reduction.
Using color and grayscale images to teach histology to color-deficient medical students.
Rubin, Lindsay R; Lackey, Wendy L; Kennedy, Frances A; Stephenson, Robert B
2009-01-01
Examination of histologic and histopathologic microscopic sections relies upon differential colors provided by staining techniques, such as hematoxylin and eosin, to delineate normal tissue components and to identify pathologic alterations in these components. Given the prevalence of color deficiency (commonly called "color blindness") in the general population, it is likely that this reliance upon color differentiation poses a significant obstacle for several medical students beginning a course of study that includes examination of histologic slides. In the past, first-year medical students at Michigan State University who identified themselves as color deficient were encouraged to use color transparency overlays or tinted contact lenses to filter out problematic colors. Recently, however, we have offered such students a computer monitor adjusted to grayscale for in-lab work, as well as grayscale copies of color photomicrographs for examination purposes. Grayscale images emphasize the texture of tissues and the contrasts between tissues as the students learn histologic architecture. Using this approach, color-deficient students have quickly learned to compensate for their deficiency by focusing on cell and tissue structure rather than on color variation. Based upon our experience with color-deficient students, we believe that grayscale photomicrographs may also prove instructional for students with normal (trichromatic) color vision, by encouraging them to consider structural characteristics of cells and tissues that may otherwise be overshadowed by stain colors.
Sloan, M A; Alexandrov, A V; Tegeler, C H; Spencer, M P; Caplan, L R; Feldmann, E; Wechsler, L R; Newell, D W; Gomez, C R; Babikian, V L; Lefkowitz, D; Goldman, R S; Armon, C; Hsu, C Y; Goodin, D S
2004-05-11
To review the use of transcranial Doppler ultrasonography (TCD) and transcranial color-coded sonography (TCCS) for diagnosis. The authors searched the literature for evidence of 1) if TCD provides useful information in specific clinical settings; 2) if using this information improves clinical decision making, as reflected by improved patient outcomes; and 3) if TCD is preferable to other diagnostic tests in these clinical situations. TCD is of established value in the screening of children aged 2 to 16 years with sickle cell disease for stroke risk (Type A, Class I) and the detection and monitoring of angiographic vasospasm after spontaneous subarachnoid hemorrhage (Type A, Class I to II). TCD and TCCS provide important information and may have value for detection of intracranial steno-occlusive disease (Type B, Class II to III), vasomotor reactivity testing (Type B, Class II to III), detection of cerebral circulatory arrest/brain death (Type A, Class II), monitoring carotid endarterectomy (Type B, Class II to III), monitoring cerebral thrombolysis (Type B, Class II to III), and monitoring coronary artery bypass graft operations (Type B to C, Class II to III). Contrast-enhanced TCD/TCCS can also provide useful information in right-to-left cardiac/extracardiac shunts (Type A, Class II), intracranial occlusive disease (Type B, Class II to IV), and hemorrhagic cerebrovascular disease (Type B, Class II to IV), although other techniques may be preferable in these settings.
Antúnez, Lucía; Giménez, Ana; Maiche, Alejandro; Ares, Gastón
2015-01-01
To study the influence of 2 interpretational aids of front-of-package (FOP) nutrition labels (color code and text descriptors) on attentional capture and consumers' understanding of nutritional information. A full factorial design was used to assess the influence of color code and text descriptors using visual search and eye tracking. Ten trained assessors participated in the visual search study and 54 consumers completed the eye-tracking study. In the visual search study, assessors were asked to indicate whether there was a label high in fat within sets of mayonnaise labels with different FOP labels. In the eye-tracking study, assessors answered a set of questions about the nutritional content of labels. The researchers used logistic regression to evaluate the influence of interpretational aids of FOP nutrition labels on the percentage of correct answers. Analyses of variance were used to evaluate the influence of the studied variables on attentional measures and participants' response times. Response times were significantly higher for monochromatic FOP labels compared with color-coded ones (3,225 vs 964 ms; P < .001), which suggests that color codes increase attentional capture. The highest number and duration of fixations and visits were recorded on labels that did not include color codes or text descriptors (P < .05). The lowest percentage of incorrect answers was observed when the nutrient level was indicated using color code and text descriptors (P < .05). The combination of color codes and text descriptors seems to be the most effective alternative to increase attentional capture and understanding of nutritional information. Copyright © 2015 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Perez, Claudio I; Chansangpetch, Sunee; Thai, Andy; Nguyen, Anh-Hien; Nguyen, Anwell; Mora, Marta; Nguyen, Ngoc; Lin, Shan C
2018-06-05
Evaluate the distribution and the color probability codes of the peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy Vietnamese population and compare them with the original color-codes provided by the Cirrus spectral domain OCT. Cross-sectional study. We recruited non-glaucomatous Vietnamese subjects and constructed a normative database for peripapillary RNFL and macular GCIPL thickness. The probability color-codes for each decade of age were calculated. We evaluated the agreement with Kappa coefficient (κ) between OCT color probability codes with Cirrus built-in original normative database and the Vietnamese normative database. 149 eyes of 149 subjects were included. The mean age of enrollees was 60.77 (±11.09) years, with a mean spherical equivalent of +0.65 (±1.58) D and mean axial length of 23.4 (±0.87) mm. Average RNFL thickness was 97.86 (±9.19) microns and average macular GCIPL was 82.49 (±6.09) microns. Agreement between original and adjusted normative database for RNFL was fair for average and inferior quadrant (κ=0.25 and 0.2, respectively); and good for other quadrants (range: κ=0.63-0.73). For macular GCIPL κ agreement ranged between 0.39 and 0.69. After adjusting with the normative Vietnamese database, the percent of yellow and red color-codes increased significantly for peripapillary RNFL thickness. Vietnamese population has a thicker RNFL in comparison with Cirrus normative database. This leads to a poor color-code agreement in average and inferior quadrant between the original and adjusted database. These findings should encourage to create a peripapillary RNFL normative database for each ethnicity.
Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat
2015-04-01
To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p < 0.05). 3-D ovarian volumes were found significantly higher in patients with PCOS (p < 0.05), and a negative correlation was also obtained between ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.
A distributed code for color in natural scenes derived from center-surround filtered cone signals
Kellner, Christian J.; Wachtler, Thomas
2013-01-01
In the retina of trichromatic primates, chromatic information is encoded in an opponent fashion and transmitted to the lateral geniculate nucleus (LGN) and visual cortex via parallel pathways. Chromatic selectivities of neurons in the LGN form two separate clusters, corresponding to two classes of cone opponency. In the visual cortex, however, the chromatic selectivities are more distributed, which is in accordance with a population code for color. Previous studies of cone signals in natural scenes typically found opponent codes with chromatic selectivities corresponding to two directions in color space. Here we investigated how the non-linear spatio-chromatic filtering in the retina influences the encoding of color signals. Cone signals were derived from hyper-spectral images of natural scenes and preprocessed by center-surround filtering and rectification, resulting in parallel ON and OFF channels. Independent Component Analysis (ICA) on these signals yielded a highly sparse code with basis functions that showed spatio-chromatic selectivities. In contrast to previous analyses of linear transformations of cone signals, chromatic selectivities were not restricted to two main chromatic axes, but were more continuously distributed in color space, similar to the population code of color in the early visual cortex. Our results indicate that spatio-chromatic processing in the retina leads to a more distributed and more efficient code for natural scenes. PMID:24098289
Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei
2011-02-01
Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Chan Hyeong; Hyoun Choi, Sang; Jeong, Jong Hwi; Lee, Choonsik; Chung, Min Suk
2008-08-01
A Korean voxel model, named 'High-Definition Reference Korean-Man (HDRK-Man)', was constructed using high-resolution color photographic images that were obtained by serially sectioning the cadaver of a 33-year-old Korean adult male. The body height and weight, the skeletal mass and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The resulting model was then implemented into a Monte Carlo particle transport code, MCNPX, to calculate the dose conversion coefficients for the internal organs and tissues. The calculated values, overall, were reasonable in comparison with the values from other adult voxel models. HDRK-Man showed higher dose conversion coefficients than other models, due to the facts that HDRK-Man has a smaller torso and that the arms of HDRK-Man are shifted backward. The developed model is believed to adequately represent average Korean radiation workers and thus can be used for more accurate calculation of dose conversion coefficients for Korean radiation workers in the future.
Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara
2015-01-01
Background: The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. Materials and Methods: In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. Results: A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Conclusions: Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta. PMID:25709996
Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara
2015-01-01
The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.
MC2-3 / DIF3D Analysis for the ZPPR-15 Doppler and Sodium Void Worth Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Micheal A.; Lell, Richard M.; Lee, Changho
This manuscript covers validation efforts for our deterministic codes at Argonne National Laboratory. The experimental results come from the ZPPR-15 work in 1985-1986 which was focused on the accuracy of physics data for the integral fast reactor concept. Results for six loadings are studied in this document and focus on Doppler sample worths and sodium void worths. The ZPPR-15 loadings are modeled using the MC2-3/DIF3D codes developed and maintained at ANL and the MCNP code from LANL. The deterministic models are generated by processing the as-built geometry information, i.e. MCNP input, and generating MC2-3 cross section generation instructions and amore » drawer homogenized equivalence problem. The Doppler reactivity worth measurements are small heated samples which insert very small amounts of reactivity into the system (< 2 pcm). The results generated by the MC2-3/DIF3D codes were excellent for ZPPR-15A and ZPPR-15B and good for ZPPR-15D, compared to the MCNP solutions. In all cases, notable improvements were made over the analysis techniques applied to the same problems in 1987. The sodium void worths from MC2-3/DIF3D were quite good at 37.5 pcm while MCNP result was 33 pcm and the measured result was 31.5 pcm. Copyright © (2015) by the American Nuclear Society All rights reserved.« less
7 CFR 1755.200 - RUS standard for splicing copper and fiber optic cables.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Color coded plastic tie wraps shall be placed loosely around each binder group of cables before splicing... conform to the same color designations as the binder ribbons. Twisted wire pigtails shall not be used to identify binder groups due to potential transmission degradation. (ii) The standard insulation color code...
Wang, Yong-Mei; Tian, Xue-Tao; Zhang, Hui; Yang, Zhong-Rui; Yin, Xue-Bo
2018-06-21
Counterfeiting is a global epidemic that is compelling the development of new anticounterfeiting strategy. Herein, we report a novel multiple anticounterfeiting encoding strategy of invisible fluorescent quick response (QR) codes with emission color as information storage unit. The strategy requires red, green, and blue (RGB) light-emitting materials for different emission colors as encrypting information, single excitation for all of the emission for practicability, and ultraviolet (UV) excitation for invisibility under daylight. Therefore, RGB light-emitting nanoscale metal-organic frameworks (NMOFs) are designed as inks to construct the colorful light-emitting boxes for information encrypting, while three black vertex boxes were used for positioning. Full-color emissions are obtained by mixing the trichromatic NMOFs inks through inkjet printer. The encrypting information capacity is easily adjusted by the number of light-emitting boxes with the infinite emission colors. The information is decoded with specific excitation light at 275 nm, making the QR codes invisible under daylight. The composition of inks, invisibility, inkjet printing, and the abundant encrypting information all contribute to multiple anticounterfeiting. The proposed QR codes pattern holds great potential for advanced anticounterfeiting.
Color-coded duplex sonography for diagnosis of testicular torsion.
Zoeller, G; Ringert, R H
1991-11-01
By color-coded duplex sonography moving structures are visualized as red or blue colors within a normal gray-scale B-mode ultrasound image. Thus, blood flow even within small vessels can be visualized clearly. Color-coded duplex sonographic examination was performed in 11 patients who presented with scrotal pain. This method proved to be reliable to differentiate between testicular torsion and testicular inflammation. By clearly demonstrating a lack of intratesticular blood flow in testicular torsion, while avoiding flow in scrotal skin vessels being misinterpreted as intratesticular blood flow, this method significantly decreases the number of patients in whom surgical evaluation is necessary to exclude testicular torsion.
NASA Astrophysics Data System (ADS)
Xue, Chengqi; Li, Jing; Wang, Haiyan; Niu, Yafeng
2015-01-01
Color coding is often used to enhance decision quality in complex man-machine interfaces of integrated display systems. However, people are easily distracted by irrelevant colors and by the numerous data points and complex structures in the interface. Although an increasing number of studies are seriously focusing on the problem of achieving efficient color coding, few are able to determine the effects of target and distractor saturations on cognitive performance. To study the performances of target colors among distractors, a systematic experiment is conducted to assess the influence of high and low saturated targets on cognitive performance, and the affecting extent of different saturated distractors of homogeneous colors on targets. According to the analysis of the reaction time through the non-parametric statistical method, a calculation method of the cognitive performance of each color is proposed. Based on the calculation of the color differences and the accumulation of the reaction times, it is shown that with the different saturated distractors of homogeneous colors, the high saturated yellow targets perform better than the low saturated ones, and the green and blue targets have moderate performances. When searching for a singleton target placed on a black background, the color difference between the target and the distractor should be more than 20Δ E*ab units in the yellow saturation coding, whereas the color difference should be more than 40Δ E*ab units in the blue and green saturation coding. In addition, as regards saturation coding, the influence of the color difference between the target and the background on cognitive performance is greater than that of the color difference between the target and the distractor. Seemingly, the hue attribute determines whether the saturation difference between the target and the distractor affects the cognitive performance. Based on the experimental results, the simulation design of the instrument dials in a flight situation awareness interface is completed and tested. Simulation results show the feasibility of the method of choosing the target and distractor colors, and the proposed research provides the instruction for the color saturation design of the interface.
Microprobes For Blood Flow Measurements In Tissue And Small Vessels
NASA Astrophysics Data System (ADS)
Oberg, P. A.; Salerud, E. G.
1988-04-01
Laser Doppler flowmetry is a method for the continuous and non-invasive recording of tissue blood flow. The method has already proved to be advantageous in a number of clinical as well as theoretical medical disciplines. In dermatology, plastic- and gastrointestinal surgery laser Doppler measurements have substantially contributed to increase knowledge of microvascular perfusion. In experimental medicine, the method has been used in the study of a great variety of microvascular problems. Spontaneous rhythmical variations, spatial and temporal fluctuations in human skin blood flow are mentioned as examples of problem areas in which new knowledge has been generated. The method has facilitated further investigations of the nature of spongeous bone blood flow, testis and kidney cortex blood flow. Recently we have showed that a variant of the laser Doppler method principle, using a single optical fiber, can be advantageous in deep tissue measurements. With this method laser light is transmitted bidirectionally in a single fiber. The tissue trauma which affects blood flow can be minimized by introducing small diameter fibers (0.1-0.5 mm). A special set-up utilizing the same basic principle has been used for the recording of blood flow in small vessels.
[Elective lymph node dissection in malignant melanoma--status of color Doppler findings].
Omlor, G; Dill-Müller, D; Gross, G; Kautz, G; Schüder, G; Zaun, H; Feifel, G
1996-01-01
Since there is still a controversial discussion about the ELND in melanoma patients, the purpose of this prospective study was to optimize the indication concerning ELND by ultrasound examinations. 144 patients with primary melanomas were checked every 3 months after excision. Echomorphologic pattern and intranodal vascularisation in the color-flow Doppler modus provide essential information for differential diagnosis. We found 47 patients (32.6%) with suspicious ultrasound lesions. 50% of these patients had no pathological clinical findings, the histological findings of excised lymph nodes were positive in all cases. It must be emphasized, however, that the group with lymph node metastases included 12 patients with low-risk-melanomas (2 x Tis, 10 x T1 < 1 mm tumor thickness). In comparison with a historical control group (141 patients), where ELND was performed routinely in high-risk-patients ( > T2), the incidence of ELND in our hospital decreased more than 50%; at the same time the percentage of detected lymph node metastases increased (twice).
NASA Astrophysics Data System (ADS)
Itatani, Keiichi; Okada, Takashi; Uejima, Tokuhisa; Tanaka, Tomohiko; Ono, Minoru; Miyaji, Kagami; Takenaka, Katsu
2013-07-01
We have developed a system to estimate velocity vector fields inside the cardiac ventricle by echocardiography and to evaluate several flow dynamical parameters to assess the pathophysiology of cardiovascular diseases. A two-dimensional continuity equation was applied to color Doppler data using speckle tracking data as boundary conditions, and the velocity component perpendicular to the echo beam line was obtained. We determined the optimal smoothing method of the color Doppler data, and the 8-pixel standard deviation of the Gaussian filter provided vorticity without nonphysiological stripe shape noise. We also determined the weight function at the bilateral boundaries given by the speckle tracking data of the ventricle or vascular wall motion, and the weight function linear to the distance from the boundary provided accurate flow velocities not only inside the vortex flow but also around near-wall regions on the basis of the results of the validation of a digital phantom of a pipe flow model.
Congenital renal arteriovenous fistula during the first trimester diagnosed with ultrasonography.
Yao, Mengyun; Zhang, Qiuyan; Wang, Jing; Xiang, Feixiang; Yu, Cheng; Lv, Qing; Xie, Mingxing; Zhang, Yanrong
2017-01-01
A case of congenital renal arteriovenous fistula (AVF) complicating pregnancy with gross hematuria was managed successfully by superselective embolization with metallic coils. The patient was in the first trimester of her pregnancy at 12 weeks of gestation. The AVF was detected by color Doppler sonography and confirmed by renal arteriography. Because of its easy accessibility and absence of irradiation, ultrasound is the first choice for pregnant patients. Color Doppler ultrasound is effective in diagnosing AVF, and it is also helpful in the long-term followup after treatment. The cirsoid-type renal congenital arteriovenous fistula has a characteristic sonographic appearance with a cluster of tubular anechoic structures in the kidney, which produce continuous turbulent high-velocity flow signals and a burr-like boundary flow spectrum. When the sonographic features are present, the diagnosis of renal AVF should be made, after which renal arteriography can be performed to confirm it. Selective embolization provided a safe and effective treatment with minimal damage to the parenchyma and without compromising renal function.
Zhong, Lin; Tang, Yuan-Jiao; Yang, Yu-Jia; Qiu, Li
2017-01-01
To explore the value of high frequency color doppler ultrasonography in differentiating benign and malignant skin solid tumors. Clinical and ultrasonic data of cutaneous solid tumors confirmed by pathology in our hospital were collected. The differences in clinical and sonographic features between benign and malignant tumors were statistically analyzed. A total of 512 patients, involving 527 cases of skin solid tumors, were enrolled in this study. The ultrasonic detected 99.43% of the cases, with 99.02% accuracy in locating the lesions. The benign and malignant tumors showed differences in patient age, location, multiple occurance, location and depth, surface skin condition, tumor size, echo, morphology, uniformity, calcification, blood flow status, tumor rear area and peripheral echo, and pathological requests ( P <0.05). High frequency ultrasound has excellent detection rate of skin tumors, which can locate invasion depth of skin accurately. Benign and malignant skin tumors show differences in a number of clinical and ultrasound features.
Internet (WWW) based system of ultrasonic image processing tools for remote image analysis.
Zeng, Hong; Fei, Ding-Yu; Fu, Cai-Ting; Kraft, Kenneth A
2003-07-01
Ultrasonic Doppler color imaging can provide anatomic information and simultaneously render flow information within blood vessels for diagnostic purpose. Many researchers are currently developing ultrasound image processing algorithms in order to provide physicians with accurate clinical parameters from the images. Because researchers use a variety of computer languages and work on different computer platforms to implement their algorithms, it is difficult for other researchers and physicians to access those programs. A system has been developed using World Wide Web (WWW) technologies and HTTP communication protocols to publish our ultrasonic Angle Independent Doppler Color Image (AIDCI) processing algorithm and several general measurement tools on the Internet, where authorized researchers and physicians can easily access the program using web browsers to carry out remote analysis of their local ultrasonic images or images provided from the database. In order to overcome potential incompatibility between programs and users' computer platforms, ActiveX technology was used in this project. The technique developed may also be used for other research fields.
Blood flow velocity measurement by endovascular Doppler optical coherence tomography
NASA Astrophysics Data System (ADS)
Sun, Cuiru; Nolte, Felix; Vuong, Barry; Cheng, Kyle H. Y.; Lee, Kenneth K. C.; Standish, Beau A.; Courtney, Brian; Marotta, Tom R.; Yang, Victor X. D.
2013-03-01
Blood flow velocity and volumetric flow measurements are important parameters for assessment of the severity of stenosis and the outcome of interventional therapy. However, feasibility of intravascular flow measurement using a rotational catheter based phase resolved Doppler optical coherence tomography (DOCT) is difficult. Motion artefacts induced by the rotating optical imaging catheter, and the radially dependent noise background of measured Doppler signals are the main challenges encountered. In this study, a custom-made data acquisition system and developed algorithms to remove non-uniform rotational distortion (NURD) induced phase shift artefact by tracking the phase shift observed on catheter sheath. The flow velocity is calculated from Doppler shift obtained by Kasai autocorrelation after motion artefact removal. Blood flow velocity profiles in porcine carotid arteries in vivo were obtained at 100 frames/s with 500 A-lines/frame and DOCT images were taken at 20 frames/s with 2500 A-lines/frame. Time-varying velocity profiles were obtained at an artery branch. Furthermore, the identification of a vein adjacent to the catheterized vessel based on the color Doppler signal was also observed. The absolute measurement of intravascular flow using a rotating fiber catheter can provide insights to different stages of interventional treatment of stenosis in carotid artery.
Christian Andreas Doppler--the man and his legacy.
Coman, I M
2005-01-01
Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.
2012-09-30
Estimation Methods for Underwater OFDM 5) Two Iterative Receivers for Distributed MIMO - OFDM with Large Doppler Deviations. 6) Asynchronous Multiuser...multi-input multi-output ( MIMO ) OFDM is also pursued, where it is shown that the proposed hybrid initialization enables drastically improved receiver...are investigated. 5) Two Iterative Receivers for Distributed MIMO - OFDM with Large Doppler Deviations. This work studies a distributed system with
Roessler, Florian C; Teichert, Andrea; Ohlrich, Marcus; Marxsen, Jan H; Stellmacher, Florian; Tanislav, Christian; Seidel, Günter
2014-11-30
Agreement about the most suitable clot formation protocol for sonothrombolysis investigations is lacking. Lysis rates vary strongly owing to different test conditions and, thus, cannot be compared. We aim to establish a simple but physiologically grounded protocol for in vitro coagulation to enable standardized sonothrombolysis investigations. Clots were generated from platelet-rich plasma (PRP) obtained by centrifugation (10 min, 180 × g) of human venous blood (VB). PRP was mixed with the boundary layer formed between the supernatant and the erythrocyte layer. To achieve clots with different platelet counts, PRP was gradually substituted with platelet-free plasma (PFP), harvested from the supernatant of VB after centrifugation (10 min, 2570 × g). Clot types were examined for histological appearance, hydrodynamic resistance under physiological flows, and lysis rate measured by weight loss after a 2-h treatment with recombinant tissue plasminogen activator (rt-PA) (60 kU/ml). Lysis rates of the most suitable clot were measured after a 1-h treatment with rt-PA (60 kU/ml), and combined treatment with rt-PA and 2-MHz transcranial color-coded sonography (TCCS) (0.179 W/cm(2)) or 2-MHz transcranial Doppler (TCD) (0.457 W/cm(2)). With increased platelet count, the hydrodynamic resistance of the artificial clots increased, their histological appearance became more physiological, and lysis rates decreased. The most suitable clots consisted of 1.5-ml PRP, 2.0-ml PFP, and 0.5-ml boundary layer. Their lysis rates were 36.7 ± 7.8% (rt-PA), 40.8 ± 8.6% (rt-PA+TCCS), and 40.4 ± 8.3% (rt-PA+TCD). These systemic investigations were conducted for the first time. This protocol should be used for standardized sonothrombolysis investigations. Copyright © 2014 Elsevier B.V. All rights reserved.
Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J
2016-06-01
There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Demirevska, L; Gotchev, D
2016-12-01
and purpose: Postoperative atrial fibrillation (POAF) is a frequent complication post high-risk abdominal surgery in elderly patients. This study aimed to develop a predictive model of POAF based on preoperative transthoracic echocardiography (TTE) findings in these patients. We conducted a prospective study of 300 consecutive patients, age ≥ 65 years (mean age 72±6 years, 61% men), who underwent high-risk abdominal surgery under general anesthesia. Preoperative TTE was performed in all patients, including tissue Doppler imaging (TDI). We measured the time interval between the onset of the P-wave on ECG and a point of the peak-A wave on TDI from the lateral mitral annulus (PA lateral) and septal mitral annulus (PA septal). Left atrial (LA) dyssynchrony was measured by subtracting the PA septal from PA lateral. Right ventricular systolic pressure was estimated by using the tricuspid regurgitation jet (TRJ) Doppler velocity method. The primary endpoint was the occurance of new-onset POAF. Thirty-seven (12%) patients developed POAF. Multiple echocardiographic parameters were measured and tested in different combinations. The final model included the following variables with cutoff points predictive of POAF: PA lateral > 139 ms (69% sensitivity, 92% specificity), LA dyssynchrony > 35 ms (78% sensitivity, 89% specificity), and TRJ Doppler velocity >2.6 m/s (89% sensitivity, 64% specificity). A value of 0 was assigned when the result was below the cutoff point and a value of 1 if above the cutoff point. Coding of these three variables in the following order: PA lateral- TRJ Doppler- left atrial dyssynchrony can predict the probability of POAF. The model showed a postive predictive value of 79% and a negative predictive value of 95%. A model using three echocardiographic variables: PA lateral, LA dyssynchrony and TRJ Doppler velocity, can predict the incidence of POAF after high-risk abdominal surgery. The model can be used preoperatively to identify high-risk patients that would need aggressive prophylactic treatment. PA lateral >139 ms-TRJ Doppler velocity >2.6 m/s-LA dyssynchrony >35 msProbability of POAF0- 0- 0; 0- 1- 0No0- 0- 1; 0- 1- 1; 1- 0- 0; 1- 0- 1; 1- 1- 0; 1- 1- 1Yes. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: Journals.permissions@oup.com.
The Pathophysiology of Decompression Sickness and the Effects of Doppler Detectable Bubbles.
1980-12-18
Doppler Ultrasound and a calibrated 6 1 Venous Gas Embol i Scale. C. Electronic Counting of Doppler Bubble Signals 72 £ III. Pulmonary Embolism Studies...IA. Background 75 B. Right Ventricular Systolic Pressure following Gas 81 Embolization and Venous Gas Phase Content IC. Effects of Pulmonary Gas... Embolism on the Development 9 of Limb-Bend Decompression Sickness 1 IV. Gas Phase Formation in Highly Perfused Tissues IA. Renal 9 B. Cerebral 9 1 I I V
Hasegawa, Kosuke; Suetsugu, Atsushi; Nakamura, Miki; Matsumoto, Takuro; Kunisada, Takahiro; Shimizu, Masahito; Saji, Shigetoyo; Moriwaki, Hisataka; Bouvet, Michael; Hoffman, Robert M
2016-09-01
Fluorescence-guided surgery (FGS) of cancer is an emerging technology. We have previously shown the importance of resecting both the tumor and the tumor microenvironment (TME) for curative FGS. We also previously developed a syngeneic model using the mouse lymphoma cell line EL-4, expressing red fluorescent protein (EL-4-RFP), growing in green fluorescent protein (GFP) transgenic mice, which we have used in the present report to develop FGS of the tumor microenvironment. EL-4-RFP lymphoma cells were injected subcutaneously in C57/BL6 GFP transgenic mice. EL-4-RFP cells subsequently formed tumors by 35 days after cell transplantation. Using the portable hand-held Dino-Lite digital imaging system, subcutaneous tumors were resected by FGS. Resected tumor tissues were visualized with the Olympus FV1000 confocal microscope. Using the Dino-Lite, subcutaneous tumors and the tumor microenvironment were clearly visualized and resected. In the resected tumor, host stromal cells, including adipocyte-like cells and blood vessels with lymphocytes, were observed by confocal microscopy in addition to cancer cells by color-coded confocal imaging. The cancer cells and stromal cells in the TME were deeply intermingled in a highly-complex pattern. Color-coded FGS is an effective method to completely resect cancer cells along with the stromal cells in the TME which interact in a highly-complex pattern. Microscopically, cancer cells invade the TME and vice versa. To prevent tumor recurrence, it is necessary to resect the TME along with the tumor. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Reds, Greens, Yellows Ease the Spelling Blues.
ERIC Educational Resources Information Center
Irwin, Virginia
1971-01-01
This document reports on a color-coding innovation designed to improve the spelling ability of high school seniors. This color-coded system is based on two assumptions: that color will appeal to the students and that there are three principal reasons for misspelling. Two groups were chosen for the experiments. A basic list of spelling demons was…
Use of Color-Coded Food Photographs for Meal Planning by Adults with Mental Retardation.
ERIC Educational Resources Information Center
Gines, Deon J.; And Others
1990-01-01
Ten adults with mild mental retardation used color-coded food photographs and meal code cards to plan nutritionally balanced meals. Subjects spent an average of nine minutes to plan three meals. Errors, which were primarily omissions, occurred mostly in food groups requiring four servings daily. (JDD)
Visual Search Asymmetries within Color-Coded and Intensity-Coded Displays
ERIC Educational Resources Information Center
Yamani, Yusuke; McCarley, Jason S.
2010-01-01
Color and intensity coding provide perceptual cues to segregate categories of objects within a visual display, allowing operators to search more efficiently for needed information. Even within a perceptually distinct subset of display elements, however, it may often be useful to prioritize items representing urgent or task-critical information.…
78 FR 59265 - FD&C Yellow No. 5; Exemption From the Requirement of a Tolerance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-26
... (NAICS code 112). Food manufacturing (NAICS code 311). Pesticide manufacturing (NAICS code 32532). B. How.... 5 is a FDA permanently listed color additive used in food, drugs and cosmetics, including drugs and cosmetics for the eye area. FDA's color additive evaluation included the consideration of an extensive set...
A Coded Structured Light System Based on Primary Color Stripe Projection and Monochrome Imaging
Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano
2013-01-01
Coded Structured Light techniques represent one of the most attractive research areas within the field of optical metrology. The coding procedures are typically based on projecting either a single pattern or a temporal sequence of patterns to provide 3D surface data. In this context, multi-slit or stripe colored patterns may be used with the aim of reducing the number of projected images. However, color imaging sensors require the use of calibration procedures to address crosstalk effects between different channels and to reduce the chromatic aberrations. In this paper, a Coded Structured Light system has been developed by integrating a color stripe projector and a monochrome camera. A discrete coding method, which combines spatial and temporal information, is generated by sequentially projecting and acquiring a small set of fringe patterns. The method allows the concurrent measurement of geometrical and chromatic data by exploiting the benefits of using a monochrome camera. The proposed methodology has been validated by measuring nominal primitive geometries and free-form shapes. The experimental results have been compared with those obtained by using a time-multiplexing gray code strategy. PMID:24129018
A coded structured light system based on primary color stripe projection and monochrome imaging.
Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano
2013-10-14
Coded Structured Light techniques represent one of the most attractive research areas within the field of optical metrology. The coding procedures are typically based on projecting either a single pattern or a temporal sequence of patterns to provide 3D surface data. In this context, multi-slit or stripe colored patterns may be used with the aim of reducing the number of projected images. However, color imaging sensors require the use of calibration procedures to address crosstalk effects between different channels and to reduce the chromatic aberrations. In this paper, a Coded Structured Light system has been developed by integrating a color stripe projector and a monochrome camera. A discrete coding method, which combines spatial and temporal information, is generated by sequentially projecting and acquiring a small set of fringe patterns. The method allows the concurrent measurement of geometrical and chromatic data by exploiting the benefits of using a monochrome camera. The proposed methodology has been validated by measuring nominal primitive geometries and free-form shapes. The experimental results have been compared with those obtained by using a time-multiplexing gray code strategy.
[Basic laws of blood screw motion in human common carotid arteries].
Kulikov, V P; Kirsanov, R I
2008-08-01
The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.
Hussein, Hassan A
2013-04-15
The aim of this study was to verify the efficacy of color Doppler ultrasonography for diagnosis of degree and duration of uterine torsion in buffaloes. In Assiut province/Upper Egypt, 65 buffaloes (37 with uterine torsion, 28 with normal late pregnancy) were examined clinically and using Doppler ultrasonography. The Doppler indices including resistance index (RI), pulsatility index (PI), time-averaged maximum velocity (TAMV), and blood flow volume (BFV) in the arteries ipsilateral to the uterine torsion (IPUT) and in arteries contralateral to the uterine torsion (COUT) were recorded. Methods of correction were documented along with dam and calf survival. Torsion was recorded postcervically with vaginal involvement in 35/37 (94.6%) of the cases. The degrees of uterine torsion were light and high in 9/37 (24.3%) and 28/37 (75.7%) of the cases, respectively (P = 0.001). Right uterine torsion was present in 36/37 (97.3%) of the cases (P = 0.0001). Pulsatility index, RI, TAMV, and BFV in IPUT and COUT did not differ significantly (P > 0.05) in normal late pregnancy. The PI and RI in IPUT were significantly higher (P < 0.01) than in COUT, and the TAMV and BFV in IPUT were less (P < 0.001) than that in COUT in uterine torsion. The PI and RI of torsion cases in IPUT were higher (P < 0.001) than that in normal pregnancy. Time-averaged maximum velocity and BFV in torsion cases were lower (P < 0.01) than that of normal pregnancy in IPUT. There was approximately 50% of RI and PI higher than in light degree uterine torsion in IPUT (P < 0.001). Consequently, TAMV and BFV were greatly lower (P < 0.0001) than that in light degree in IPUT. Pulsatility index and RI were positively correlated (r = 0.856; P < 0.001) with the duration and degree of the uterine torsion, and TAMV and BFV were negatively correlated (r = -0.763; P < 0.001). In all cases of uterine torsion the uterine flow velocity waveform showed high systolic flow and absence of early diastolic flow and poor uterine and placentomal blood perfusion. In conclusion, depicting blood flow within the middle uterine artery using color Doppler sonography could be helpful in correct diagnosis of duration and degree of uterine torsion and concurrently predicting the viability of the fetus and dam. Copyright © 2013 Elsevier Inc. All rights reserved.
Digital Controller For Emergency Beacon
NASA Technical Reports Server (NTRS)
Ivancic, William D.
1990-01-01
Prototype digital controller intended for use in 406-MHz emergency beacon. Undergoing development according to international specifications, 406-MHz emergency beacon system includes satellites providing worldwide monitoring of beacons, with Doppler tracking to locate each beacon within 5 km. Controller turns beacon on and off and generates binary codes identifying source (e.g., ship, aircraft, person, or vehicle on land). Codes transmitted by phase modulation. Knowing code, monitor attempts to communicate with user, monitor uses code information to dispatch rescue team appropriate to type and locations of carrier.
Evaluation of contrast-enhanced power Doppler imaging for measuring blood flow
NASA Astrophysics Data System (ADS)
Ansaloni, Sara; Arger, Peter H.; Cary, Ted W.; Sehgal, Chandra M.
2005-04-01
Power Doppler ultrasound enhanced by microbubble contrast agent has been used to image tissue vascularity and blood flow for the assessment of antivascular therapies. We have proposed a multigating technique that measures bubble concentration as a function of ultrasound exposure for deriving tumor blood flow and vascularity.1 Techniques using ultrasound contrast agent are known to be sensitive to the choice of imaging parameters like mechanical index and tissue attenuation. In this paper, the roles of mechanical index (MI) and tissue attenuation were evaluated experimentally in a rubber tubing flow phantom connected to a mixing chamber and a variable speed pump. The contrast was injected in the mixing chamber and the flow rate was measured using power Doppler imaging. The measurements were repeated at different MIs (0.1 to 1.3), and at different levels of attenuation, obtained with solutions of glycerol-water (10-20%). True flow was measured by collecting liquid flowing out of the phantom over a fixed duration. At low MI (<0.5), the grayscale and Doppler signal were weak, making these images unsuitable for analysis. At higher MI (> 0.8), there was a well-defined enhancement by contrast agent resulting in reproducible flow measurements at variable MIs. A balance between the number of bubbles destroyed and the echo they generate must be achieved for optimal imaging. The increased attenuation of ultrasound by the overlying medium did not influence the flow measurements.
Color reproduction for advanced manufacture of soft tissue prostheses.
Xiao, Kaida; Zardawi, Faraedon; van Noort, Richard; Yates, Julian M
2013-11-01
The objectives of this study were to develop a color reproduction system in advanced manufacture technology for accurate and automatic processing of soft tissue prostheses. The manufacturing protocol was defined to effectively and consistently produce soft tissue prostheses using a 3D printing system. Within this protocol printer color profiles were developed using a number of mathematical models for the proposed 3D color printing system based on 240 training colors. On this basis, the color reproduction system was established and their system errors including accuracy of color reproduction, performance of color repeatability and color gamut were evaluated using 14 known human skin shades. The printer color profile developed using the third-order polynomial regression based on least-square fitting provided the best model performance. The results demonstrated that by using the proposed color reproduction system, 14 different skin colors could be reproduced and excellent color reproduction performance achieved. Evaluation of the system's color repeatability revealed a demonstrable system error and this highlighted the need for regular evaluation. The color gamut for the proposed 3D printing system was simulated and it was demonstrated that the vast majority of skin colors can be reproduced with the exception of extreme dark or light skin color shades. This study demonstrated that the proposed color reproduction system can be effectively used to reproduce a range of human skin colors for application in advanced manufacture of soft tissue prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Structure-Preserving Color Normalization and Sparse Stain Separation for Histological Images.
Vahadane, Abhishek; Peng, Tingying; Sethi, Amit; Albarqouni, Shadi; Wang, Lichao; Baust, Maximilian; Steiger, Katja; Schlitter, Anna Melissa; Esposito, Irene; Navab, Nassir
2016-08-01
Staining and scanning of tissue samples for microscopic examination is fraught with undesirable color variations arising from differences in raw materials and manufacturing techniques of stain vendors, staining protocols of labs, and color responses of digital scanners. When comparing tissue samples, color normalization and stain separation of the tissue images can be helpful for both pathologists and software. Techniques that are used for natural images fail to utilize structural properties of stained tissue samples and produce undesirable color distortions. The stain concentration cannot be negative. Tissue samples are stained with only a few stains and most tissue regions are characterized by at most one effective stain. We model these physical phenomena that define the tissue structure by first decomposing images in an unsupervised manner into stain density maps that are sparse and non-negative. For a given image, we combine its stain density maps with stain color basis of a pathologist-preferred target image, thus altering only its color while preserving its structure described by the maps. Stain density correlation with ground truth and preference by pathologists were higher for images normalized using our method when compared to other alternatives. We also propose a computationally faster extension of this technique for large whole-slide images that selects an appropriate patch sample instead of using the entire image to compute the stain color basis.
Vibration amplitude sonoelastography lesion imaging using low-frequency audible vibration
NASA Astrophysics Data System (ADS)
Taylor, Lawrence; Parker, Kevin
2003-04-01
Sonoelastography or vibration amplitude imaging is an ultrasound imaging technique in which low-amplitude, low-frequency shear waves, less than 0.1-mm displacement and 1-kHz frequency, are propagated deep into tissue, while real time Doppler techniques are used to image the resulting vibration pattern. Finite-element studies and experiments on tissue-mimicking phantoms verify that a discrete hard inhomogeneity present within a larger region of soft tissue will cause a decrease in the vibration field at its location. This forms the basis for tumor detection using sonoelastography. Real time relative imaging of the vibration field is possible because a vibrating particle will phase modulate an ultrasound signal. The particle's amplitude is directly proportional to the spectral spread of the reflected Doppler echo. Real time estimation of the variance of the Doppler power spectrum at each pixel allows the vibration field to be imaged. Results are shown for phantom lesions, thermal lesions, and 3-D in vitro and 2-D in vivo prostate cancer. MRI and whole mount histology is used to validate the system accuracy.
Kim, Jeong Tae; Ho, Samuel Y M; Kim, Youn Hwan
2014-02-01
Postoperative flap monitoring is a vital aspect of free tissue transfer in order to detect early vascular compromise and to enable early flap salvage. The implantable Doppler monitoring system is one of many monitoring devices used to ensure accuracy and reduce unnecessary flap explorations. However, there are a number of concerns with its use, namely tension on the anastomosis, possible vessel constriction and false-negative detection. This study aimed to alleviate these concerns, by introducing a new method of placing the implantable Doppler probe on the adjacent vessel limb of a chimaeric flap. This is illustrated by a case series of chimaeric free tissue flaps that allow this surrogate placement of the Doppler probe. The flap is raised in a chimaeric fashion, with a main perforator pedicle to the skin or muscle paddle for the main reconstructive purpose and a side branch from the main pedicle going to a smaller adipofascial or muscle flap for monitoring. This branch vascular pedicle leading to the chimaeric tissue is kept sufficiently long to enable placement of the Doppler cuff and prevent turbulence. The probe of a Cook-Swartz implantable Doppler system is placed around the branch pedicle, approximately 5 mm from the branching point, and secured with a vessel clip. This is then secured away from the major vessels of the main free flap. Removal of the probe's crystal and wire is easily done with a single gentle traction on postoperative day 7. Five cases of chimaeric free flaps were performed with this manoeuvre: three thoracodorsal perforator chimaeric flaps for head-and-neck or extremity reconstruction, one latissimus dorsi neuromuscular chimaeric flap for facial reanimation and one digastric lymph node transfer for the treatment of lower limb lymphoedema. The Doppler system showed a low but sustained oscillating flow in all cases indicating vascular patency, with minimal flow interference from other large-calibre vessels. There was no discernible kinking on the anastomosis. There were no complications encountered during probe removal. This postoperative monitoring manoeuvre was done successfully with good results. The monitoring equipment is very sensitive to any flow disturbance due to positional changes in the head-and-neck region or the extremities and is able to detect flow changes in buried flaps postoperatively. Chimaeric flap composition is easier now than before because of perforator-oriented pedicle dissection, and surrogate Doppler monitoring is one more application of the chimaeric flap. This novel chimaeric fashion of implantable Doppler probe placement is a good surrogate measure of flow in the main pedicle. Copyright © 2013. Published by Elsevier Ltd.
New Skeletal-Space-Filling Models
ERIC Educational Resources Information Center
Clarke, Frank H.
1977-01-01
Describes plastic, skeletal molecular models that are color-coded and can illustrate both the conformation and overall shape of small molecules. They can also be converted to space-filling counterparts by the additions of color-coded polystyrene spheres. (MLH)
[Antenatal diagnosis of placenta accreta].
Malinova, M
2014-01-01
Placenta accreta is a potentially life-threatening obstetric condition. Diagnosis of placenta accreta before delivery allows multidisciplinary planning in an attempt to minimize potential maternal or neonatal morbidity and mortality The diagnosis is usually established by 2D, 3D Ultrasonography and Color Doppler ultrasonography and occasionally supplemented by Magnetic Resonance Imaging.
USDA-ARS?s Scientific Manuscript database
Color Doppler ultasonography was used to evaluate vasoconstrictive responses of the testicular artery in yearling bulls to ergot alkaloids. Ergot alkaloid-induced constriction of the testicular artery could disrupt thermoregulation of the testes and reduce bull fertility. Luminal areas of the test...
15 CFR Appendix A to Part 950 - Schedule of User Fees for Access to NOAA Environmental Data
Code of Federal Regulations, 2014 CFR
2014-01-01
... In-Situ Digital Data 6.00 (*) Data Poster 18.00 18.00 Shipping Service for orders totaling less than...: NEXRAD Doppler Radar Color Prints 17.00 14.00 Paper Copy from Electronic Media 6.00 6.00 Offline In-Situ...
How to identify up to 30 colors without training: color concept retrieval by free color naming
NASA Astrophysics Data System (ADS)
Derefeldt, Gunilla A. M.; Swartling, Tiina
1994-05-01
Used as a redundant code, color is shown to be advantageous in visual search tasks. It enhances attention, detection, and recall of information. Neuropsychological and neurophysiological findings have shown color and spatial perception to be interrelated functions. Studies on eye movements show that colored symbols are easier to detect and that eye fixations are more correctly directed to color-coded symbols. Usually between 5 and 15 colors have been found useful in classification tasks, but this umber can be increased to between 20 to 30 by careful selection of colors, and by a subject's practice with the identification task and familiarity with the particular colors. Recent neurophysiological findings concerning the language-concept connection in color suggest that color concept retrieval would be enhanced by free color naming or by the use of natural associations between color concepts and color words. To test this hypothesis, we had subjects give their own free associations to a set of 35 colors presented on a display. They were able to identify as many as 30 colors without training.
NASA Astrophysics Data System (ADS)
Saleheen, Firdous; Badano, Aldo; Cheng, Wei-Chung
2017-03-01
The color reproducibility of two whole-slide imaging (WSI) devices was evaluated with biological tissue slides. Three tissue slides (human colon, skin, and kidney) were used to test a modern and a legacy WSI devices. The color truth of the tissue slides was obtained using a multispectral imaging system. The output WSI images were compared with the color truth to calculate the color difference for each pixel. A psychophysical experiment was also conducted to measure the perceptual color reproducibility (PCR) of the same slides with four subjects. The experiment results show that the mean color differences of the modern, legacy, and monochrome WSI devices are 10.94+/-4.19, 22.35+/-8.99, and 42.74+/-2.96 ▵E00, while their mean PCRs are 70.35+/-7.64%, 23.06+/-14.68%, and 0.91+/-1.01%, respectively.
A color-coded vision scheme for robotics
NASA Technical Reports Server (NTRS)
Johnson, Kelley Tina
1991-01-01
Most vision systems for robotic applications rely entirely on the extraction of information from gray-level images. Humans, however, regularly depend on color to discriminate between objects. Therefore, the inclusion of color in a robot vision system seems a natural extension of the existing gray-level capabilities. A method for robot object recognition using a color-coding classification scheme is discussed. The scheme is based on an algebraic system in which a two-dimensional color image is represented as a polynomial of two variables. The system is then used to find the color contour of objects. In a controlled environment, such as that of the in-orbit space station, a particular class of objects can thus be quickly recognized by its color.
Balli, Sevket; Yucel, Ilker Kemal; Kibar, Ayse Esin; Ece, Ibrahim; Dalkiran, Eylem Sen; Candan, Sukru
2016-11-01
Extra genetic material in patients with Down syndrome (DS) may affect the function of any organ system. We evaluated cardiac functions using conventional tissue Doppler and two-dimensional speckle tracking echocardiography in patients with DS in the absence of congenital and acquired heart disease in patients. A total of 115 patients with DS between 6 and 13 years of age with clinically and anatomically normal heart and 55 healthy children were included in this cross-sectional study. DS was diagnosed by a karyotype test. Patients with mosaic type were not included in this study. Systolic and diastolic functions were evaluated by echocardiography. Pulsed waved Doppler transmitral early/late inflow velocity (E/A), tissue Doppler mitral annular early/late diastolic peak velocity (Ea/Aa), transtricuspid E/A and tricuspid valve annulus Ea/Aa, pulmonary venous Doppler systolic/diastolic (S/D) wave ratio were lower in patients with Down syndrome than in the control group (P=0.04, P=0.001, P<0.05, P<0.001, P<0.001, respectively). Mitral and tricuspid annular Ea were lower in patients with DS (P<0.001). The right and left ventricular myocardial performance indexes were higher in patients with DS than in the controls (P<0.01). They had significantly higher left ventricular mass, ejection fraction, the mitral annular plane systolic excursion values. However, the Down syndrome group compared with the controls had a lower strain values examined by two-dimensional longitudinal speckle-tracking strain echocardiography. These findings suggest conventional tissue Doppler and two-dimensional longitudinal speckletracking strain echocardiography were useful methods of investigating ventricular function and identifying a higher incidence of biventricular dysfunction in patients with Down syndrome compared with the healthy controls.
Doppler imaging using spectrally-encoded endoscopy
Yelin, Dvir; Bouma, B. E.; Rosowsky, J. J.; Tearney, G. J.
2009-01-01
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique that utilizes a single optical fiber and miniature diffractive optics to obtain endoscopic images through small diameter probes. Using spectral-domain interferometry, SEE is furthermore capable of three-dimensional volume imaging at video rates. Here we show that by measuring relative spectral phases, this technology can additionally measure Doppler shifts. Doppler SEE is demonstrated in flowing Intralipid phantoms and vibrating middle ear ossicles. PMID:18795020
The implementation of thermal image visualization by HDL based on pseudo-color
NASA Astrophysics Data System (ADS)
Zhu, Yong; Zhang, JiangLing
2004-11-01
The pseudo-color method which maps the sampled data to intuitive perception colors is a kind of powerful visualization way. And the all-around system of pseudo-color visualization, which includes the primary principle, model and HDL (Hardware Description Language) implementation for the thermal images, is expatiated on in the paper. The thermal images whose signal is modulated as video reflect the temperature distribution of measured object, so they have the speciality of mass and real-time. The solution to the intractable problem is as follows: First, the reasonable system, i.e. the combining of global pseudo-color visualization and local special area accurate measure, muse be adopted. Then, the HDL pseudo-color algorithms in SoC (System on Chip) carry out the system to ensure the real-time. Finally, the key HDL algorithms for direct gray levels connection coding, proportional gray levels map coding and enhanced gray levels map coding are presented, and its simulation results are showed. The pseudo-color visualization of thermal images implemented by HDL in the paper has effective application in the aspect of electric power equipment test and medical health diagnosis.
Some Notes on Neutron Up-Scattering and the Doppler-Broadening of High-Z Scattering Resonances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsons, Donald Kent
When neutrons are scattered by target nuclei at elevated temperatures, it is entirely possible that the neutron will actually gain energy (i.e., up-scatter) from the interaction. This phenomenon is in addition to the more usual case of the neutron losing energy (i.e., down-scatter). Furthermore, the motion of the target nuclei can also cause extended neutron down-scattering, i.e., the neutrons can and do scatter to energies lower than predicted by the simple asymptotic models. In recent years, more attention has been given to temperature-dependent scattering cross sections for materials in neutron multiplying systems. This has led to the inclusion of neutronmore » up-scatter in deterministic codes like Partisn and to free gas scattering models for material temperature effects in Monte Carlo codes like MCNP and cross section processing codes like NJOY. The free gas scattering models have the effect of Doppler Broadening the scattering cross section output spectra in energy and angle. The current state of Doppler-Broadening numerical techniques used at Los Alamos for scattering resonances will be reviewed, and suggestions will be made for further developments. The focus will be on the free gas scattering models currently in use and the development of new models to include high-Z resonance scattering effects. These models change the neutron up-scattering behavior.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matthew Ellis; Derek Gaston; Benoit Forget
In recent years the use of Monte Carlo methods for modeling reactors has become feasible due to the increasing availability of massively parallel computer systems. One of the primary challenges yet to be fully resolved, however, is the efficient and accurate inclusion of multiphysics feedback in Monte Carlo simulations. The research in this paper presents a preliminary coupling of the open source Monte Carlo code OpenMC with the open source Multiphysics Object-Oriented Simulation Environment (MOOSE). The coupling of OpenMC and MOOSE will be used to investigate efficient and accurate numerical methods needed to include multiphysics feedback in Monte Carlo codes.more » An investigation into the sensitivity of Doppler feedback to fuel temperature approximations using a two dimensional 17x17 PWR fuel assembly is presented in this paper. The results show a functioning multiphysics coupling between OpenMC and MOOSE. The coupling utilizes Functional Expansion Tallies to accurately and efficiently transfer pin power distributions tallied in OpenMC to unstructured finite element meshes used in MOOSE. The two dimensional PWR fuel assembly case also demonstrates that for a simplified model the pin-by-pin doppler feedback can be adequately replicated by scaling a representative pin based on pin relative powers.« less
Joint pain and Doppler-detectable bubbles in altitude (Hypobaric) decompression
NASA Technical Reports Server (NTRS)
Powell, Michael R.
1993-01-01
The observation that altitude decompression sickness (DCS) is associated with pain in the lower extremities is not new, although it is not a consistent finding. DCS in divers is generally in the upper body, an effect often attributed to non-loading of the body while immersed. In caisson workers, DCS is reported more in the lower extremities. Surprisingly, many researchers do not mention the location of DCS joint pain, apparently considering it to be random. This is not the case for the tissue ratios encountered in studying decompression associated with simulated EVA. In NASA/JSC tests, altitude DCS generally presented first in either the ankle, knee, or hip (83 percent = 73/88). There was a definite statistical relation between the maximum Spencer precordial Doppler Grade and the incidence of DCS in the extremity, although this is not meant to imply a casual relation between circulating gas bubbles and joint pain. The risk of DCS with Grade 4 was considerably higher than that of Grades 0 to 3. The DCS risk was independent of the 'tissue ratio.' There was a predominance of lower extremity DCS even when exercise was performed with the upper body. The reason for these locations we hypothesize to be attributed to the formation of tissue gas micronuclei from kinetic and tensile forces (stress-assisted nucleation) and are the result of the individuals ambulating in a 1g environment. Additionally, since these showers of Doppler bubbles can persist for hours, it is difficult to imagine that they are emanating solely from tendons and ligaments, the supposed site of joint pain. This follows from Henry's law linking the volume of joint tissue (the solvent) and the solubility coefficient of inert gas; there is volumetrically insufficient connective tissue to produce the prolonged release of gas bubbles. If gas bubbles are spawned and released from connective tissue, their volume is increased by those from muscle tissue. Therefore, the nexus between Doppler-detectable gas bubbles and joint-pain decompression sickness is essentially a statistical, rather than a direct, one.
Color identification testing device
NASA Technical Reports Server (NTRS)
Brawner, E. L.; Martin, R.; Pate, W.
1970-01-01
Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.
Küpper, Clemens; Burke, Terry; Lank, David B.
2015-01-01
Sequence variation in the melanocortin-1 receptor (MC1R) gene explains color morph variation in several species of birds and mammals. Ruffs (Philomachus pugnax) exhibit major dark/light color differences in melanin-based male breeding plumage which is closely associated with alternative reproductive behavior. A previous study identified a microsatellite marker (Ppu020) near the MC1R locus associated with the presence/absence of ornamental plumage. We investigated whether coding sequence variation in the MC1R gene explains major dark/light plumage color variation and/or the presence/absence of ornamental plumage in ruffs. Among 821bp of the MC1R coding region from 44 male ruffs we found 3 single nucleotide polymorphisms, representing 1 nonsynonymous and 2 synonymous amino acid substitutions. None were associated with major dark/light color differences or the presence/absence of ornamental plumage. At all amino acid sites known to be functionally important in other avian species with dark/light plumage color variation, ruffs were either monomorphic or the shared polymorphism did not coincide with color morph. Neither ornamental plumage color differences nor the presence/absence of ornamental plumage in ruffs are likely to be caused entirely by amino acid variation within the coding regions of the MC1R locus. Regulatory elements and structural variation at other loci may be involved in melanin expression and contribute to the extreme plumage polymorphism observed in this species. PMID:25534935
The photo-colorimetric space as a medium for the representation of spatial data
NASA Technical Reports Server (NTRS)
Kraiss, K. Friedrich; Widdel, Heino
1989-01-01
Spatial displays and instruments are usually used in the context of vehicle guidance, but it is hard to find applicable spatial formats in information retrieval and interaction systems. Human interaction with spatial data structures and the applicability of the CIE color space to improve dialogue transparency is discussed. A proposal is made to use the color space to code spatially represented data. The semantic distances of the categories of dialogue structures or, more general, of database structures, are determined empirically. Subsequently the distances are transformed and depicted into the color space. The concept is demonstrated for a car diagnosis system, where the category cooling system could, e.g., be coded in blue, the category ignition system in red. Hereby a correspondence between color and semantic distances is achieved. Subcategories can be coded as luminance differences within the color space.
Landing Hazard Avoidance Display
NASA Technical Reports Server (NTRS)
Abernathy, Michael Franklin (Inventor); Hirsh, Robert L. (Inventor)
2016-01-01
Landing hazard avoidance displays can provide rapidly understood visual indications of where it is safe to land a vehicle and where it is unsafe to land a vehicle. Color coded maps can indicate zones in two dimensions relative to the vehicles position where it is safe to land. The map can be simply green (safe) and red (unsafe) areas with an indication of scale or can be a color coding of another map such as a surface map. The color coding can be determined in real time based on topological measurements and safety criteria to thereby adapt to dynamic, unknown, or partially known environments.
Compress compound images in H.264/MPGE-4 AVC by exploiting spatial correlation.
Lan, Cuiling; Shi, Guangming; Wu, Feng
2010-04-01
Compound images are a combination of text, graphics and natural image. They present strong anisotropic features, especially on the text and graphics parts. These anisotropic features often render conventional compression inefficient. Thus, this paper proposes a novel coding scheme from the H.264 intraframe coding. In the scheme, two new intramodes are developed to better exploit spatial correlation in compound images. The first is the residual scalar quantization (RSQ) mode, where intrapredicted residues are directly quantized and coded without transform. The second is the base colors and index map (BCIM) mode that can be viewed as an adaptive color quantization. In this mode, an image block is represented by several representative colors, referred to as base colors, and an index map to compress. Every block selects its coding mode from two new modes and the previous intramodes in H.264 by rate-distortion optimization (RDO). Experimental results show that the proposed scheme improves the coding efficiency even more than 10 dB at most bit rates for compound images and keeps a comparable efficient performance to H.264 for natural images.
NASA Technical Reports Server (NTRS)
Firstenberg, M. S.; Levine, B. D.; Garcia, M. J.; Greenberg, N. L.; Cardon, L.; Morehead, A. J.; Zuckerman, J.; Thomas, J. D.
2000-01-01
OBJECTIVES: We sought to determine the relationship between different echocardiographic indices and pulmonary capillary wedge pressures (PCWP) in normal volunteers. BACKGROUND: Indices based on tissue Doppler (TDE) and color M-mode (CMM) echocardiography have been proposed to reflect left (LV) ventricular filling pressures. These include the ratio of early diastolic transmitral velocity (E) to early myocardial velocity measured by TDE (E') and the ratio of E to the wave propagation velocity (Vp) measured from CMM images. These indices, however, have not been validated in normal individuals. METHODS: We studied seven volunteers during two phases of preload altering maneuvers, baseline, with two stages of lower body negative pressure, and repeat baseline with two stages of volume loading. The PCWP obtained from right heart catheterization was compared with diastolic indices using pulsed Doppler, TDE and CMM echocardiography. RESULTS: The PCWP ranged from 2.2 to 23.5 mm Hg. During preload alterations, significant changes in E and septal E' (both p < 0.05) but not lateral E' or Vp were observed. Furthermore, E, septal E' and E/Vp correlated with PCWP (all r > 0.80) but not combined E and TDE indices (both r < 0.15). Within individuals, a similar linear relationship was observed among E/Vp, E and septal E' (average r > 0.80). CONCLUSIONS: In subjects without heart disease, E, septal E' and E/Vp correlate with PCWP. Because the influence of ventricular relaxation is minimized, the ratio E/Vp may be the best overall index of LV filling pressures.
Arques, Stephane; Roux, Emmanuel; Sbragia, Pascal; Pieri, Bertrand; Gelisse, Richard; Luccioni, Roger; Ambrosi, Pierre
2007-05-01
The incremental role of bedside tissue Doppler echocardiography and B-type natriuretic peptide (BNP) over the clinical judgment has been recently reported in the emergency diagnosis of congestive heart failure with a normal left ventricular ejection fraction (HFNEF). However, how well does this diagnostic strategy be applicable in the setting of atrial fibrillation is unknown. To investigate the usefulness of bedside tissue Doppler echocardiography and BNP in the emergency diagnosis of HFNEF in elderly patients with permanent, nonvalvular atrial fibrillation. Forty-one consecutive elderly patients with an ejection fraction > or =50% (mean age 84 years; 22 with HFNEF and 19 with noncardiac cause), hospitalized for acute dyspnea at rest, were prospectively enrolled; bedside septal E/Ea and BNP were obtained at admission. By multivariable logistic regression analysis including the clinical judgment of heart failure, E/Ea and BNP, E/Ea (P = 0.014) and BNP (P = 0.018) provided independent diagnostic information. Optimal cutoffs were 13 for E/Ea (area under the ROC curve of 0.846, P < 0.0001; sensitivity 81.8%, specificity 89.5%) and 253 pg/ml for BNP (area under the ROC curve of 0.928, P < 0.0001; sensitivity 86.4%, specificity 89.5%). The concordance between the clinical judgment and BNP concentration at the cutoff of 253 pg/ml correctly classified 24 of 25 patients; E/Ea at the cutoff of 13 correctly classified 14 of the 16 patients with discrepancy. Bedside tissue Doppler echocardiography and BNP provide useful additional diagnostic information over the clinical judgment for the emergency diagnosis of HFNEF in elderly patients with permanent, nonvalvular atrial fibrillation.
Arques, Stephane; Roux, Emmanuel; Sbragia, Pascal; Pieri, Bertrand; Gelisse, Richard; Ambrosi, Pierre; Luccioni, Roger
2006-09-01
Based on the hypothesis that it reflects left ventricular (LV) diastolic pressures, B-type natriuretic peptide (BNP) is largely utilized as first-line diagnostic complement in the emergency diagnosis of congestive heart failure (HF). The incremental diagnostic value of tissue Doppler echocardiography, a reliable noninvasive estimate of LV filling pressures, has been reported in patients with preserved LV ejection fraction and discrepancy between BNP levels and the clinical judgment, however, its clinical validity in such patients in the presence of BNP concentrations in the midrange, which may reflect intermediate, nondiagnostic levels of LV filling pressures, is unknown. 34 patients without history of HF, presenting with acute dyspnea at rest, BNP levels of 100-400 pg/ml and normal LV ejection fraction were prospectively enrolled (17 with congestive HF and 17 with noncardiac cause). Tissue Doppler echocardiography was performed within 3 hours after admission. Unlike BNP (P = 0.78), Boston criteria (P = 0.0129), radiographic pulmonary edema (P = 0.0036) and average E/Ea ratio (P = 0.0032) were predictive of congestive HF by logistic regression analysis. In this clinical setting, radiographic pulmonary edema had a positive predictive value of 80% in the diagnosis of congestive HF. In patients without evidence of radiographic pulmonary edema, average E/Ea > 10 was a powerful predictor of congestive HF (area under the ROC curve of 0.886, P < 0.001, sensitivity 100% and specificity 78.6%). By better reflecting LV filling pressures, bedside tissue Doppler echocardiography accurately differentiates congestive HF from noncardiac cause in dyspneic patients with intermediate, nondiagnostic BNP levels and normal LV ejection fraction.
El Saiedi, Sonia A; Mira, Marwa F; Sharaf, Sahar A; Al Musaddar, Maysoun M; El Kaffas, Rania M H; AbdelMassih, Antoine F; Barsoum, Ihab H Y
2018-01-01
Obesity increases the risk for various cardiovascular problems. Increase in body mass index is often an independent risk factor for the development of elevated blood pressure and clustering of various cardiovascular risk factors. To determine early markers of left ventricular affection in obese patients before the appearance of left ventricular hypertrophy. In this cross-sectional study, we evaluated 42 obese patients and 30 healthy controls. Their ages ranged from 6 to 19 years. Studied children were subjected to anthropometric, lipid profile, and serum Troponin I level measurements. Echocardiographic evaluation performed to assess the left ventricle included left ventricular dimension measurement using motion-mode echocardiography, based on which patients with left ventricular hypertrophy (10 patients) were eliminated, as well as conventional and tissue Doppler imaging. Tissue Doppler findings in the study groups showed that the ratio of transmitral early diastolic filling velocity to septal peak early diastolic myocardial velocity (E/e') was significantly higher in cases compared with controls [6.9±1.4 versus 9.0±1.6, p (Pearson's coefficient)=0.001, respectively]. The level of cardiac troponin I was significantly higher in cases compared with controls [0.14±0.39 ng/ml versus 0.01±0.01 ng/ml, p (Pearson's coefficient)=0.047, respectively] and there was a significant correlation between troponin I and transmitral early diastolic filling velocity to septal peak early diastolic myocardial velocity ratio (E/e') [R (correlation coefficient)=0.6]. Tissue Doppler Imaging and Troponin I evaluation proved useful tools to detect early affection of the left ventricle in obese patients even in the absence of left ventricular hypertrophy.
Theoretical research on color indirect effects
NASA Astrophysics Data System (ADS)
Liu, T. C.; Liao, Changjun; Liu, Songhao
1995-05-01
Color indirect effects (CIE) means the physiological and psychological effects of color resulting from color vision. In this paper, we study CIE from the viewpoints of the integrated western and Chinese traditional medicine and the time quantum theory established by C. Y. Liu et al., respectively, and then put forward the color-automatic-nervous-subsystem model that could color excites parasympathetic subsystem and hot color excites sympathetic subsystem. Our theory is in agreement with modern color vision theory, and moreover, it leads to the resolution of the conflict between the color code theory and the time code theory oncolor vision. For the latitude phenomena on athlete stars number and the average lifespan, we also discuss the possibility of UV vision. The applications of our theory lead to our succeeding in explaining a number of physiological and psychological effects of color, in explaining the effects of age on color vision, and in explaining the Chinese chromophototherapy. We also discuss its application to neuroimmunology. This research provides the foundation of the clinical applications of chromophototherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayashi, A.; Hashimoto, T.; Horibe, M.
The quantum color coding scheme proposed by Korff and Kempe [e-print quant-ph/0405086] is easily extended so that the color coding quantum system is allowed to be entangled with an extra auxiliary quantum system. It is shown that in the extended scheme we need only {approx}2{radical}(N) quantum colors to order N objects in large N limit, whereas {approx}N/e quantum colors are required in the original nonextended version. The maximum success probability has asymptotics expressed by the Tracy-Widom distribution of the largest eigenvalue of a random Gaussian unitary ensemble (GUE) matrix.
Multi-colored fibers by self-assembly of DNA, histone proteins, and cationic conjugated polymers.
Wang, Fengyan; Liu, Zhang; Wang, Bing; Feng, Liheng; Liu, Libing; Lv, Fengting; Wang, Yilin; Wang, Shu
2014-01-07
The development of biomolecular fiber materials with imaging ability has become more and more useful for biological applications. In this work, cationic conjugated polymers (CCPs) were used to construct inherent fluorescent microfibers with natural biological macromolecules (DNA and histone proteins) through the interfacial polyelectrolyte complexation (IPC) procedure. Isothermal titration microcalorimetry results show that the driving forces for fiber formation are electrostatic and hydrophobic interactions, as well as the release of counterions and bound water molecules. Color-encoded IPC fibers were also obtained based on the co-assembly of DNA, histone proteins, and blue-, green-, or red- (RGB-) emissive CCPs by tuning the fluorescence resonance energy-transfer among the CCPs at a single excitation wavelength. The fibers could encapsulate GFP-coded Escherichia coli BL21, and the expression of GFP proteins was successfully regulated by the external environment of the fibers. These multi-colored fibers show a great potential in biomedical applications, such as biosensor, delivery, and release of biological molecules and tissue engineering. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Extended Colour--Some Methods and Applications.
ERIC Educational Resources Information Center
Dean, P. J.; Murkett, A. J.
1985-01-01
Describes how color graphics are built up on microcomputer displays and how a range of colors can be produced. Discusses the logic of color formation, noting that adding/subtracting color can be conveniently demonstrated. Color generating techniques in physics (resistor color coding and continuous spectrum production) are given with program…
Trellis coding techniques for mobile communications
NASA Technical Reports Server (NTRS)
Divsalar, D.; Simon, M. K.; Jedrey, T.
1988-01-01
A criterion for designing optimum trellis codes to be used over fading channels is given. A technique is shown for reducing certain multiple trellis codes, optimally designed for the fading channel, to conventional (i.e., multiplicity one) trellis codes. The computational cutoff rate R0 is evaluated for MPSK transmitted over fading channels. Examples of trellis codes optimally designed for the Rayleigh fading channel are given and compared with respect to R0. Two types of modulation/demodulation techniques are considered, namely coherent (using pilot tone-aided carrier recovery) and differentially coherent with Doppler frequency correction. Simulation results are given for end-to-end performance of two trellis-coded systems.
Ultrasound SIV measurement of helical valvular flow behind the great saphenous vein
NASA Astrophysics Data System (ADS)
Park, Jun Hong; Kim, Jeong Ju; Lee, Sang Joon; Yeom, Eunseop; Experimental Fluid Mechanics Laboratory Team; LaboratoryMicrothermal; Microfluidic Measurements Collaboration
2017-11-01
Dysfunction of venous valve and induced secondary abnormal flow are closely associated with venous diseases. Thus, detailed analysis of venous valvular flow is invaluable from biological and medical perspectives. However, most previous studies on venous perivalvular flows were based on qualitative analyses. On the contrary, quantitative analysis on the perivalvular flows has not been fully understood yet. In this study, 3D valvular flows under in vitro and in vivo conditions were experimentally investigated using ultrasound speckle image velocimetry (SIV) for analyzing their flow characteristics. The results for in vitro model obtained by the SIV technique were compared with those derived by numerical simulation and color Doppler method to validate its measurement accuracy. Then blood flow in the human great saphenous vein was measured using the SIV with respect to the dimensionless index, helical intensity. The results obtained by the SIV method are well matched well with those obtained by the numerical simulation and color Doppler method. The hemodynamic characteristics of 3D valvular flows measured by the validated SIV method would be helpful in diagnosis of valve-related venous diseases. None.
Rocher, L; Feretti, L; Camparo, P; Savoie, P H; Morel-Journel, N; Murez, T; Sebe, P; Flechon, A; Méjean, A; Durand, X
2018-04-09
Help in management of non-palpable testicular tumors. French Urologic Association Genital cancer committee's Edit. To review their characterization at imaging findings of non-palpable testicular tumors. Literature review (PubMed, Medline) of urological and radiological studies dealing with testicular tumors using keywords: non-palpable/incidental testicular tumors; color Doppler ultrasound; US elastography; magnetic resonance imaging; contrast enhanced sonography; partial surgery. Color Doppler is the basic exam. The size, the presence of microlithts/microlithiasis/macrocalcifications, the vascular architecture are major semiological findings to suggest the benign or the malignant nature of the lesion. Other techniques like multiparametric MRI, contrast-enhanced sonography, sonographic elastography are still in evaluation. The frequency of benign tumors such as Leydig cell tumors lead to preservation management, through improved characterization, monitoring or tumorectomy. Non-randomized study - a very few prospective studies. The era of total orchiectomy for any uncertain testicular lesion is over. We try the challenge of characterization, and define management's algorithms based on the suspected nature of the tumors. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Multiple-Parameter Estimation Method Based on Spatio-Temporal 2-D Processing for Bistatic MIMO Radar
Yang, Shouguo; Li, Yong; Zhang, Kunhui; Tang, Weiping
2015-01-01
A novel spatio-temporal 2-dimensional (2-D) processing method that can jointly estimate the transmitting-receiving azimuth and Doppler frequency for bistatic multiple-input multiple-output (MIMO) radar in the presence of spatial colored noise and an unknown number of targets is proposed. In the temporal domain, the cross-correlation of the matched filters’ outputs for different time-delay sampling is used to eliminate the spatial colored noise. In the spatial domain, the proposed method uses a diagonal loading method and subspace theory to estimate the direction of departure (DOD) and direction of arrival (DOA), and the Doppler frequency can then be accurately estimated through the estimation of the DOD and DOA. By skipping target number estimation and the eigenvalue decomposition (EVD) of the data covariance matrix estimation and only requiring a one-dimensional search, the proposed method achieves low computational complexity. Furthermore, the proposed method is suitable for bistatic MIMO radar with an arbitrary transmitted and received geometrical configuration. The correction and efficiency of the proposed method are verified by computer simulation results. PMID:26694385
Yang, Shouguo; Li, Yong; Zhang, Kunhui; Tang, Weiping
2015-12-14
A novel spatio-temporal 2-dimensional (2-D) processing method that can jointly estimate the transmitting-receiving azimuth and Doppler frequency for bistatic multiple-input multiple-output (MIMO) radar in the presence of spatial colored noise and an unknown number of targets is proposed. In the temporal domain, the cross-correlation of the matched filters' outputs for different time-delay sampling is used to eliminate the spatial colored noise. In the spatial domain, the proposed method uses a diagonal loading method and subspace theory to estimate the direction of departure (DOD) and direction of arrival (DOA), and the Doppler frequency can then be accurately estimated through the estimation of the DOD and DOA. By skipping target number estimation and the eigenvalue decomposition (EVD) of the data covariance matrix estimation and only requiring a one-dimensional search, the proposed method achieves low computational complexity. Furthermore, the proposed method is suitable for bistatic MIMO radar with an arbitrary transmitted and received geometrical configuration. The correction and efficiency of the proposed method are verified by computer simulation results.
NASA Astrophysics Data System (ADS)
Tejman-Yarden, Shai; Rzasa, Callie; Benito, Yolanda; Alhama, Marta; Leone, Tina; Yotti, Raquel; Bermejo, Javier; Printz, Beth; Del Alamo, Juan C.
2012-11-01
Left ventricular vortices have been difficult to visualize in the clinical setting due to the lack of quantitative non-invasive modalities, and this limitation is especially important in pediatrics. We have developed and validated a new technique to reconstruct two-dimensional time-resolved velocity fields in the LV from conventional transthoracic color-Doppler images. This non-invasive modality was used to image LV flow in 10 healthy full-term neonates, ages 24-48 hours. Our results show that, in neonates, a diastolic vortex developed during LV filling, was maintained during isovolumic contraction, and decayed during the ejection period. The vortex was created near the base of the ventricle, moved toward the apex, and then back toward the base and LVOT during ejection. In conclusion, we have characterized for the first time the properties of the LV filling vortex in normal neonates, demonstrating that this vortex channels blood from the inflow to the outflow tract of the LV. Together with existing data from adults, our results confirm that the LV vortex is conserved through adulthood. Funded by NIH Grant R21HL108268.
Mancini, Andrea; Castriotta, Giuseppe; Angelini, Pernina; Bozzi, Michele; Giancaspro, Vincenzo; La Raia, Elvira; Nisi, Maria Teresa; Proscia, Anna Rita; Tarantino, Giuseppe; Vitale, Ottavia; Cuzzola, Cristoforo
2017-06-01
A pseudoaneurysm or false aneurysm of the brachial artery is an uncommon occurrence in patients receiving hemodialysis with arteriovenous fistula (AVF). We describe the case of a 76-year-old woman presenting with a large, tender, pulsatile mass in the right antecubital region 10 cm from the AVF. B-mode ultrasound examination revealed a saccular hematoma. Color doppler showed a recirculation movement of blood, creating a two colors image called "Korean flag". The patient was transferred to the surgical unit where she first underwent ultrasound-guided compression and then surgical repair of the pseudoaneurysm. Two weeks after surgery the AVF was used again as an access for hemodialysis. Differentiating between a false and a true aneurysm based on ultrasound is not always straightforward. Doppler ultrasound findings can be decisive for the early diagnosis of a pseudoaneurysm to ensure proper treatment planning given the dangerous complications of ruptures. Treatment options include: compression, percutaneous thrombin injection, endovascular exclusion with covered stents, aneurysmectomy and surgical repair. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.
Application of the laser Doppler velocimeter in aerodynamic flows
NASA Technical Reports Server (NTRS)
Yanta, W. J.; Ausherman, D. W.
1982-01-01
Applications of the laser doppler velocimeter (LDV) are discussed. Measurements were made of the flowfield around a tangent-ogive model in a low turbulent, incompressible flow at an incidence of 45 deg. The free-stream velocity was 80 ft per second. The flowfield velocities in several cross-flow planes were measured with a 2-D, two-color LDC operated in a backscatter mode. Measurements were concentrated in the secondary separation region. A typical survey is given. The survey was taken at a model location where the maximum side force occurs. The overall character of the leeward flowfield with the influence of the two body vorticles are shown. Measurements of the velocity and density flowfields in the shock-layer region of a reentry-vehicle indented nose configuration were carried out at Mach 5. The velocity flowfield was measured with a 2-color, 2-D, forward-scatter LDV system. Because of the need to minimize particle lag in the shock-layer region, polystyrene particles with a mean diameter of 0.312 microns were used for the scattering particles. The model diameter was 6 inches.
Color and Vector Flow Imaging in Parallel Ultrasound With Sub-Nyquist Sampling.
Madiena, Craig; Faurie, Julia; Poree, Jonathan; Garcia, Damien; Garcia, Damien; Madiena, Craig; Faurie, Julia; Poree, Jonathan
2018-05-01
RF acquisition with a high-performance multichannel ultrasound system generates massive data sets in short periods of time, especially in "ultrafast" ultrasound when digital receive beamforming is required. Sampling at a rate four times the carrier frequency is the standard procedure since this rule complies with the Nyquist-Shannon sampling theorem and simplifies quadrature sampling. Bandpass sampling (or undersampling) outputs a bandpass signal at a rate lower than the maximal frequency without harmful aliasing. Advantages over Nyquist sampling are reduced storage volumes and data workflow, and simplified digital signal processing tasks. We used RF undersampling in color flow imaging (CFI) and vector flow imaging (VFI) to decrease data volume significantly (factor of 3 to 13 in our configurations). CFI and VFI with Nyquist and sub-Nyquist samplings were compared in vitro and in vivo. The estimate errors due to undersampling were small or marginal, which illustrates that Doppler and vector Doppler images can be correctly computed with a drastically reduced amount of RF samples. Undersampling can be a method of choice in CFI and VFI to avoid information overload and reduce data transfer and storage.
Bakhshi, Hooman; Alavi-Moghaddam, Mostafa; Wu, Karin C; Imami, Mohammad; Banasiri, Mohammad
2012-06-01
Measuring the plasma levels of D-dimer is an accurate and easy modality to detect deep vein thrombosis (DVT) in nontraumatic settings. However, the diagnostic reliability of D-dimer assays in detecting posttraumatic DVT among patients with lower limb fracture undergoing orthopedic surgery is not validated. In this study, 141 patients with lower limb fracture admitted through the emergency department and undergoing orthopedic surgery were enrolled. Postoperative venous blood samples for D-dimer assay were taken on the 1st, 7th, and 28th postoperative days. Color Doppler sonography examination of both lower limbs was performed at the same time as a standard test. Eight out of the 141 patients (6%) had acute DVT based on Color Doppler sonography. Mean D-dimer was 2160 ng/mL in DVT positive patients and 864 in DVT negative patients. D-dimer levels greater than 1000 ng/mL were 100% sensitive and 71% specific for detecting postoperative DVT. D-dimer assay is a useful and sensitive test for detecting posttraumatic DVT.
Fetal vascular adaptation before and after treatment of severe maternal anemia in pregnancy.
Ali, Eram; Kumar, Manisha; Naqvi, Sayyed E H; Trivedi, Shubha S; Singh, Anuradha
2016-06-01
To use color Doppler ultrasonography indices to study the effects on fetal circulation of treating severe maternal anemia. A prospective cohort study enrolled patients who were at 30-34weeks of pregnancy and had hemoglobin levels below 70g/L between November 1, 2011 and March 31, 2013 at a hospital in New Delhi, India. A control group consisting of patients with the same duration of pregnancy and with hemoglobin levels above 110g/L was included. Umbilical artery and middle cerebral artery velocimetry were performed using color Doppler ultrasonography at admission and after 4weeks and 6weeks of treatment. The maternal anemia cohort demonstrated a significantly lower middle cerebral artery resistance index and middle cerebral/umbilical artery resistance ratio (P<0.001) at admission. Following 4weeks of treatment for maternal anemia, significant increases in these parameters were observed (P<0.001). Fetuses of individuals with severe maternal anemia demonstrated altered cerebral and umbilical artery flows. Normal flows were restored following treatment of maternal anemia. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.
Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang
2015-10-01
The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.
Seol, Bo Ram; Kim, Dong Myung; Park, Ki Ho; Jeoung, Jin Wook
2017-11-01
To evaluate the optical coherence tomography (OCT) color probability codes based on a myopic normative database and to investigate whether the implementation of the myopic normative database can improve the OCT diagnostic ability in myopic glaucoma. Comparative validity study. In this study, 305 eyes (154 myopic healthy eyes and 151 myopic glaucoma eyes) were included. A myopic normative database was obtained based on myopic healthy eyes. We evaluated the agreement between OCT color probability codes after applying the built-in and myopic normative databases, respectively. Another 120 eyes (60 myopic healthy eyes and 60 myopic glaucoma eyes) were included and the diagnostic performance of OCT color codes using a myopic normative database was investigated. The mean weighted kappa (Kw) coefficients for quadrant retinal nerve fiber layer (RNFL) thickness, clock-hour RNFL thickness, and ganglion cell-inner plexiform layer (GCIPL) thickness were 0.636, 0.627, and 0.564, respectively. The myopic normative database showed a higher specificity than did the built-in normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P < .001, P < .001, and P < .001, respectively). The receiver operating characteristic curve values increased when using the myopic normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P = .011, P = .004, P < .001, respectively). The diagnostic ability of OCT color codes for detection of myopic glaucoma significantly improved after application of the myopic normative database. The implementation of a myopic normative database is needed to allow more precise interpretation of OCT color probability codes when used in myopic eyes. Copyright © 2017 Elsevier Inc. All rights reserved.
Moreira, Maria E; Hernandez, Caleb; Stevens, Allen D; Jones, Seth; Sande, Margaret; Blumen, Jason R; Hopkins, Emily; Bakes, Katherine; Haukoos, Jason S
2015-08-01
The Institute of Medicine has called on the US health care system to identify and reduce medical errors. Unfortunately, medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients when dosing requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national health care priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared with conventional medication administration, in simulated pediatric emergency department (ED) resuscitation scenarios. We performed a prospective, block-randomized, crossover study in which 10 emergency physician and nurse teams managed 2 simulated pediatric arrest scenarios in situ, using either prefilled, color-coded syringes (intervention) or conventional drug administration methods (control). The ED resuscitation room and the intravenous medication port were video recorded during the simulations. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the conventional and color-coded delivery groups was 47 seconds (95% confidence interval [CI] 40 to 53 seconds) and 19 seconds (95% CI 18 to 20 seconds), respectively (difference=27 seconds; 95% CI 21 to 33 seconds). With the conventional method, 118 doses were administered, with 20 critical dosing errors (17%); with the color-coded method, 123 doses were administered, with 0 critical dosing errors (difference=17%; 95% CI 4% to 30%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by emergency physician and nurse teams during simulated pediatric ED resuscitations. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Kang, Jeeun; Yoon, Changhan; Lee, Jaejin; Kye, Sang-Bum; Lee, Yongbae; Chang, Jin Ho; Kim, Gi-Duck; Yoo, Yangmo; Song, Tai-kyong
2016-04-01
In this paper, we present a novel system-on-chip (SOC) solution for a portable ultrasound imaging system (PUS) for point-of-care applications. The PUS-SOC includes all of the signal processing modules (i.e., the transmit and dynamic receive beamformer modules, mid- and back-end processors, and color Doppler processors) as well as an efficient architecture for hardware-based imaging methods (e.g., dynamic delay calculation, multi-beamforming, and coded excitation and compression). The PUS-SOC was fabricated using a UMC 130-nm NAND process and has 16.8 GFLOPS of computing power with a total equivalent gate count of 12.1 million, which is comparable to a Pentium-4 CPU. The size and power consumption of the PUS-SOC are 27×27 mm(2) and 1.2 W, respectively. Based on the PUS-SOC, a prototype hand-held US imaging system was implemented. Phantom experiments demonstrated that the PUS-SOC can provide appropriate image quality for point-of-care applications with a compact PDA size ( 200×120×45 mm(3)) and 3 hours of battery life.
The vascular nature of hemorrhoids.
Aigner, Felix; Bodner, Gerd; Gruber, Hannes; Conrad, Friedrich; Fritsch, Helga; Margreiter, Raimund; Bonatti, Hugo
2006-01-01
The arterial blood supply of the internal hemorrhoidal plexus is commonly believed to be associated with the pathogenesis of hemorrhoids. Ultrasound-supported proctoscopic techniques with Doppler-guided ligature of submucosal rectal arteries have been introduced for the therapy of hemorrhoids. The present investigation focuses on caliber and flow changes of the terminal branches of the superior rectal artery (SRA) supplying the corpus cavernosum recti (CCR) in patients with hemorrhoids. Forty-one outpatients (17 female, 24 male; mean age 48 years) with hemorrhoids of Goligher grades I-IV were compared with 17 healthy volunteers (nine female, eight male; mean age 29 years) by means of transperineal color Doppler ultrasound. The mean caliber of the arterial branches in the study group with hemorrhoids was 1.87 +/- 0.68 mm (range, 0.6 to 3.60 mm) and 0.92 +/- 0.15 mm (range, 0.6 to 1.2 mm) in the control group (P < 0.001). The arterial blood flow was significantly higher in patients with hemorrhoids than in the control group (mean 33.9 vs. 11.9 cm/second, P < 0.01). Our findings demonstrate that increased caliber and arterial blood flow of the terminal branches of the SRA are correlated with the appearance of hemorrhoids. We suggest that the hypervascularization of the anorectum contributes to the growth of hemorrhoids rather than being a consequence of hemorrhoids. Transperineal color Doppler ultrasound (CDUS) is an appropriate method to assess these findings in patients with hemorrhoids.
The effect of ambient lighting on Laser Doppler Imaging of a standardized cutaneous injury model.
Pham, Alan Chuong Q; Hei, Erik La; Harvey, John G; Holland, Andrew Ja
2017-01-01
The aim of this study was to investigate the potential confounding effects of four different types of ambient lighting on the results of Laser Doppler Imaging (LDI) of a standardized cutaneous injury model. After applying a mechanical stimulus to the anterior forearm of a healthy volunteer and inducing a wheal and arteriolar flare (the Triple response), we used a Laser Doppler Line Scanner (LDLS) to image the forearm under four different types of ambient lighting: light-emitting-diode (LED), compact fluorescent lighting (CFL), halogen, daylight, and darkness as a control. A spectrometer was used to measure the intensity of light energy at 785 nm, the wavelength used by the scanner for measurement under each type of ambient lighting. Neither the LED nor CFL bulbs emitted detectable light energy at a wavelength of 785 nm. The color-based representation of arbitrary perfusion unit (APU) values of the Triple response measured by the scanner was similar between darkness, LED, and CFL light. Daylight emitted 2 mW at 785 nm, with a slight variation tending more towards lower APU values compared to darkness. Halogen lighting emitted 6 mW of light energy at 785 nm rendering the color-based representation impossible to interpret. Halogen lighting and daylight have the potential to confound results of LDI of cutaneous injuries whereas LED and CFL lighting did not. Any potential sources of daylight should be reduced and halogen lighting completely covered or turned off prior to wound imaging.
Diana, Alessia; Guglielmini, Carlo; Pivetta, Mauro; Sanacore, Antonina; Di Tommaso, Morena; Lord, Peter F; Cipone, Mario
2009-11-01
To evaluate radiographic distribution of pulmonary edema (PE) in dogs with mitral regurgitation (MR) and investigate the association between location of radiographic findings and direction of the mitral regurgitant jet (MRJ). Retrospective case series. 61 dogs with cardiogenic PE and MR resulting from mitral valve disease (MVD; 51 dogs), dilated cardiomyopathy (9), and hypertrophic cardiomyopathy (1). Thoracic radiographs of dogs with Doppler echocardiographic evidence of MR were reviewed for location (diffuse, perihilar, or focal) of PE. Also, direction (central or eccentric) of the MRJ, as evaluated by Doppler color flow mapping (DCFM), and distribution (symmetric or asymmetric) of radiographic findings were evaluated. Diffuse, perihilar, and focal increases in pulmonary opacity were observed in 11 (18.0%), 7 (11.5%), and 43 (70.5%) of 61 dogs, respectively. Radiographic evidence of asymmetric PE in a single lung lobe or 2 ipsilateral lobes was found in 21 dogs, with involvement of only the right caudal lung lobe in 17 dogs. Doppler color flow mapping of the MRJ was available for 46 dogs. Of 31 dogs with a central MRJ, 28 had radiographic findings indicative of symmetric PE. Of 15 dogs with eccentric MRJ, 11 had radiographic evidence of asymmetric PE, and all of these dogs had MVD. In dogs with cardiogenic PE, a symmetric radiographic distribution of increased pulmonary opacity was predominantly associated with a central MRJ, whereas an asymmetric radiographic distribution was usually associated with eccentric MRJ, especially in dogs with MVD.
Assessment of the fetomaternal circulation in threatened abortion by transvaginal color Doppler.
Kurjak, A; Zudenigo, D; Predanic, M; Kupesic, S; Funduk, B
1994-01-01
Transvaginal color Doppler was used to investigate blood flow in the fetomaternal circulation of 60 women with threatened abortion and 90 women with normal intrauterine pregnancy. The obtained Doppler sonograms were analyzed and the resistance index (RI) was calculated in the maternal circulation, while in the fetal circulation the pulsatility index (PI) was used. There was no significant difference in the RI values of the maternal circulation between women with normal pregnancies and pregnancies complicated by bleeding, but with normal pregnancy outcome (p > 0.05). No differences in RI values of the uterine, arcuate and radial arteries were found between pregnancies with threatened abortion and normal pregnancy outcome and women with abnormal outcome (p > 0.05). In 9 of 21 women with visible retrochorionic hematoma, the RI of the spiral arteries was higher on the hematoma side in comparison to the opposite side (p < 0.01). This could be a consequence of the mechanical compression caused by the hematoma. In 3 of 4 cases of missed abortion, the RI of the spiral arteries was lower in comparison to the control group. Such findings could be caused by the vasodilatating products of inflammation which probably exist in such areas. There was no significant difference in terms of the PI of fetal blood vessels between normal pregnancy and threatened abortions with normal outcome, as well as between threatened abortions with normal outcome and subsequent abortions of live fetuses (p > 0.05).
Kawai, Junichi; Tanabe, Kazuaki; Matsuzaki, Masashi; Yamaguchi, Kazuto; Yagi, Toshikazu; Fujii, Yoko; Konda, Toshiko; Ui, Kazuyo; Sumida, Toshiaki; Okada, Midori; Tani, Tomoko; Morioka, Shigefumi
2003-10-01
This study evaluated the accuracy of the directional color power Doppler (DCPD) and continuous wave Doppler (CWD) methods incorporated in the new hand-carried SonoSite 180PLUS ultrasound device. The hand-held ultrasound system with 2.5 MHz transducer and SONOS 5500 was used as a standard ultrasound system with a 2 to 4 MHz wideband transducer. The experimental study used a Doppler wire phantom to evaluate the influence of target wire speed and angle of transducer on DCPD imaging. The clinical study included 48 consecutive patients. DCPD assessment of valvular regurgitation measured the distances of DCPD signals of mitral, aortic and tricuspid valve regurgitation using the apical four-chamber view for comparison with standard echocardiography. CWD assessment measured the peak velocities of the aortic flow and tricuspid valve regurgitant flow for comparison with standard echocardiography. In the experimental study, DCPD signals were not influenced by target wire speed changes and transducer incident angles. In the clinical study, agreements for mitral, aortic and tricuspid regurgitation between the two methods were 89.6%, 81.8% and 78.7%, respectively. The distances of DCPD valve regurgitant signals by the hand-carried ultrasound device showed good correlation (mitral regurgitation: y = 0.84x + 0.55; r = 0.93, aortic regurgitation: y = 0.95x + 0.27; r = 0.94, tricuspid regurgitation: y = 0.86x + 0.61; r = 0.90) with those by standard echocardiography. Evaluation of CWD velocity measurements showed good agreement for the lower flow velocities (< 2.0 m/sec). However, underestimation occurred for the high flow velocities (> 2.0 m/sec) compared with those by standard echocardiography (aortic flow: y = 0.80x + 0.11; r = 0.95, tricuspid regurgitation: y = 1.00x - 0.23; r = 0.90). The new hand-carried ultrasound device (SonoSite 180PLUS equipped with DCPD and CWD) is clinically useful for evaluating valvular regurgitations and flow velocities. Further studies are needed to determine the mechanism of the underestimation of high flow velocities by CWD.
Algül, Ali; Balci, Pinar; Seçil, Mustafa; Canda, Tülay
2003-06-01
To compare ability of detection of vascular structures by utilizing ultrasonographic contrast agent (Levovist) prior to and following power Doppler ultrasound (PDUS) and colour Doppler ultrasound (CDUS) and to determine useful parameters in the differentiation of malignant and benign breast masses by means of verified data. Vascularisation characteristics of 38 breast masses (22 malignant, 16 benign) which were confirmed by mammography and B-mode sonography were evaluated by both CDUS and PDUS following and prior to intravenous contrast application. In addition, Vmax and RI values of vascular structures were calculated by Doppler spectral evaluation. Malignant lesions showed more vascularity than benign lesions both with and without contrast enhancement. With both methods, by utilizing contrast agent, central, penetrating and tortuous vascular structures became more significant in malignant lesions when compared with benign lesions. PDUS was able to detect vascular structures better than CDUS; however, the difference was not statistically significant. Presence of peripheral vascularity was not useful in differentiating malignant from benign lesions. Vmax and RI values were higher in malignant lesions and the difference was statistically significant. In both methods, Vmax > 15 cm/sec and RI > 0.80 (CDUS), and RI > 0.70 (PDUS) were accepted as malignancy parameters. Vascular patterns of breast masses as determined with PDUS and CDUS with contrast enhancement and Doppler spectral examinations enabled differentiation of malignant and benign breast lesions. Thus, it is possible to decrease the number of unnecessary surgical interventions.
Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color.
Ferrari, Marco; Carrabba, Michele; Vichi, Alessandro; Goracci, Cecilia; Cagidiaco, Maria Crysanti
Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (≥ 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO₂. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l'Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO₂ group. All the patients with thin soft tissues reported color changes that exceeded the critical threshold. The different abutment materials showed comparable results in terms of influence on soft tissue color. Regarding peri-implant soft tissue thickness, the influence of the tested abutments on soft tissue color became clinically relevant for values ≤ 2 mm.
Iizaka, Shinji; Sugama, Junko; Nakagami, Gojiro; Kaitani, Toshiko; Naito, Ayumi; Koyanagi, Hiroe; Matsuo, Junko; Kadono, Takafumi; Konya, Chizuko; Sanada, Hiromi
2011-01-01
Granulation tissue color is one indicator for pressure ulcer (PU) assessment. However, it entails a subjective evaluation only, and quantitative methods have not been established. We developed color indicators from digital image analysis and investigated their concurrent validity and reliability for clinical PUs. A cross-sectional study was conducted on 47 patients with 55 full-thickness PUs. After color calibration, a wound photograph was converted into three images representing red color: erythema index (EI), modified erythema index with additional color calibration (granulation red index [GRI]), and , which represents the artificially created red-green axis of L(*) a(*) b(*) color space. The mean intensity of the granulation tissue region and the percentage of pixels exceeding the optimal cutoff intensity (% intensity) were calculated. Mean GRI (ρ=0.39, p=0.007) and (ρ=0.55, p<0.001), as well as their % intensity indicators, showed positive correlations with a(*) measured by tristimulus colorimeter, but erythema index did not. They were correlated with hydroxyproline concentration in wound fluid, healthy granulation tissue area, and blood hemoglobin level. Intra- and interrater reliability of the indicator calculation using both GRI and had an intraclass correlation coefficient >0.9. GRI and from digital image analysis can quantitatively evaluate granulation tissue color of clinical PUs. © 2011 by the Wound Healing Society.
Götze, A; Honnens, A; Flachowsky, G; Bollwein, H
2010-01-01
The goals of the present study were to measure mammary blood flow volume (BFV) during the first 12 wk of lactation in dairy cows by using color Doppler sonography and to determine what affects the mammary blood flow. Forty cows were examined via color Doppler sonography on d 1, 7, 14, 28, 56, and 84 after parturition (d 0). The total BFV (BFV(total)) to the 4 mammary glands was calculated by measuring time-averaged maximum velocities (TAMV) and cross-sectional areas (A) of the left and right pudendoepigastric trunks via transrectal color Doppler sonography. Because there were no significant differences in A, TAMV, and BFV between the right and left pudendoepigastric trunks, the means of A and TAMV, and the BFV(total) of both trunks were used for calculations. The intraindividual and interindividual variability of repeated BFV measures quantified by intraclass correlation coefficients were 96 and 98%, respectively. The BFV(total) ranged from 19.9 to 27.9 L/min, with a mean of 22.3+/-4.9 L/min. Interindividual differences in BFV values were attributable to variations in A and TAMV. The interindividual variability of the BFV(total), which was determined using the coefficients of variation of the BFV(total) on individual days, ranged from 16 to 28%. All the cows had similar changes in the BFV(total) during the study. Changes in BFV(total) were not correlated with changes in the mean of A, but there was a good correlation between changes in BFV(total) and in the mean of TAMV (r=0.94). The BFV(total) was highest on d 1 of lactation, decreased 28% by d 7, and remained at this level until d 28. By d 56, the BFV(total) had increased by 15% compared with d 14 and by 10% compared with d 28. The BFV(total) on d 84 was significantly different from all other days except d 56. There were moderate correlations between daily milk yield and BFV on individual days (0.24
The effect of a redundant color code on an overlearned identification task
NASA Technical Reports Server (NTRS)
Obrien, Kevin
1992-01-01
The possibility of finding redundancy gains with overlearned tasks was examined using a paradigm varying familiarity with the stimulus set. Redundant coding in a multidimensional stimulus was demonstrated to result in increased identification accuracy and decreased latency of identification when compared to stimuli varying on only one dimension. The advantages attributable to redundant coding are referred to as redundancy gain and were found for a variety of stimulus dimension combinations, including the use of hue or color as one of the dimensions. Factors that have affected redundancy gain include the discriminability of the levels of one stimulus dimension and the level of stimulus-to-response association. The results demonstrated that response time is in part a function of familiarity, but no effect of redundant color coding was demonstrated. Implications of research on coding in identification tasks for display design are discussed.
Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong
2014-07-01
The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P < 0.05). The detection rate of each pulmonary vein when employing low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.
Vessel packaging effect in laser speckle contrast imaging and laser Doppler imaging.
Fredriksson, Ingemar; Larsson, Marcus
2017-10-01
Laser speckle-based techniques are frequently used to assess microcirculatory blood flow. Perfusion estimates are calculated either by analyzing the speckle fluctuations over time as in laser Doppler flowmetry (LDF), or by analyzing the speckle contrast as in laser speckle contrast imaging (LSCI). The perfusion estimates depend on the amount of blood and its speed distribution. However, the perfusion estimates are commonly given in arbitrary units as they are nonlinear and depend on the magnitude and the spatial distribution of the optical properties in the tissue under investigation. We describe how the spatial confinement of blood to vessels, called the vessel packaging effect, can be modeled in LDF and LSCI, which affect the Doppler power spectra and speckle contrast, and the underlying bio-optical mechanisms for these effects. As an example, the perfusion estimate is reduced by 25% for LDF and often more than 50% for LSCI when blood is located in vessels with an average diameter of 40 μm, instead of being homogeneously distributed within the tissue. This significant effect can be compensated for only with knowledge of the average diameter of the vessels in the tissue. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Tafreshi, Azadeh Kamali; Top, Can Barış; Gençer, Nevzat Güneri
2017-06-21
Harmonic motion microwave Doppler imaging (HMMDI) is a novel imaging modality for imaging the coupled electrical and mechanical properties of body tissues. In this paper, we used two experimental systems with different receiver configurations to obtain HMMDI images from tissue-mimicking phantoms at multiple vibration frequencies between 15 Hz and 35 Hz. In the first system, we used a spectrum analyzer to obtain the Doppler data in the frequency domain, while in the second one, we used a homodyne receiver that was designed to acquire time-domain data. The developed phantoms mimicked the elastic and dielectric properties of breast fat tissue, and included a [Formula: see text] mm cylindrical inclusion representing the tumor. A focused ultrasound probe was mechanically scanned in two lateral dimensions to obtain two-dimensional HMMDI images of the phantoms. The inclusions were resolved inside the fat phantom using both experimental setups. The image resolution increased with increasing vibration frequency. The designed receiver showed higher sensitivity than the spectrum analyzer measurements. The results also showed that time-domain data acquisition should be used to fully exploit the potential of the HMMDI method.
Grudzińska, Ewa; Modrzejewska, Monika
2018-01-01
Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.
NASA Astrophysics Data System (ADS)
Kamali Tafreshi, Azadeh; Barış Top, Can; Güneri Gençer, Nevzat
2017-06-01
Harmonic motion microwave Doppler imaging (HMMDI) is a novel imaging modality for imaging the coupled electrical and mechanical properties of body tissues. In this paper, we used two experimental systems with different receiver configurations to obtain HMMDI images from tissue-mimicking phantoms at multiple vibration frequencies between 15 Hz and 35 Hz. In the first system, we used a spectrum analyzer to obtain the Doppler data in the frequency domain, while in the second one, we used a homodyne receiver that was designed to acquire time-domain data. The developed phantoms mimicked the elastic and dielectric properties of breast fat tissue, and included a 14~\\text{mm}× 9 mm cylindrical inclusion representing the tumor. A focused ultrasound probe was mechanically scanned in two lateral dimensions to obtain two-dimensional HMMDI images of the phantoms. The inclusions were resolved inside the fat phantom using both experimental setups. The image resolution increased with increasing vibration frequency. The designed receiver showed higher sensitivity than the spectrum analyzer measurements. The results also showed that time-domain data acquisition should be used to fully exploit the potential of the HMMDI method.
Characterizing cardiac dysfunction in fetuses with left congenital diaphragmatic hernia.
Cruz-Lemini, Mónica; Valenzuela-Alcaraz, Brenda; Granados-Montiel, Julio; Martínez, Josep M; Crispi, Fátima; Gratacós, Eduard; Cruz-Martínez, Rogelio
2018-03-23
To evaluate cardiac function by conventional echocardiography and tissue Doppler imaging in fetuses with left congenital diaphragmatic hernia (CDH). Conventional echocardiography (myocardial performance index, ventricular filling velocities, and E/A ratios) and tissue Doppler imaging (annular myocardial peak velocities, E/E' and E'/A' ratios) in mitral, septal, and tricuspid annulus were evaluated in a cohort of 31 left-sided CDH fetuses and compared with 75 controls matched for gestational age 2:1. In comparison to controls, CDH fetuses had prolonged isovolumetric time periods (isovolumetric contraction time 35 ms vs 28 ms, P < .001), with higher myocardial performance index (0.49 vs 0.42, P < .001) and tricuspid E/A ratios (0.77 vs 0.72, P = .033). Longitudinal function assessed by tissue Doppler showed signs of impaired relaxation (mitral lateral A' 8.0 vs 10.1 cm/s, P < .001 and an increased mitral lateral E'/A' ratio 0.93 vs 0.78, P < .001) in the CDH fetuses as compared with controls, with preserved systolic function. Left CDH fetuses show echocardiographic signs of diastolic dysfunction, probably secondary to fetal heart compression, maintaining a preserved systolic function. © 2018 John Wiley & Sons, Ltd.
Meng, Nana; Liu, Jing; Zhang, Yue; Ma, Jinlan; Li, Hao; Qu, Yi
2014-08-01
To analyze hemodynamic changes in retrobulbar blood vessels using color Doppler imaging in diabetic patients without or with retinopathy. Pertinent publications were retrieved from 3 databases. Changes in peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI) of the ophthalmic artery, central retinal artery, and short posterior ciliary artery of diabetic eyes without or with retinopathy and healthy controls were evaluated by color Doppler imaging. Comparisons were conducted in 3 groups: group 1, no retinopathy versus control; group 2, retinopathy versus control; and group 3, no retinopathy versus retinopathy. In group 1, eyes without retinopathy had a significant increase in ophthalmic artery PSV (P = .002), with no heterogeneity (Pheterogeneity = 0.09; inconsistency index [I(2)] = 46%); however, significant reductions in central renal artery PSV and EDV were shown (P = .002; P = .007, respectively), with significant heterogeneity (Pheterogeneity < .00001; I(2) = 85%; Pheterogeneity = .008, I(2) = 68%). A significant increase in ophthalmic artery RI (P = .02) was found in eyes without retinopathy, with heterogeneity (Pheterogeneity = .0009; I(2) = 74%). In group 2, central retinal artery PSV and EDV in eyes with retinopathy decreased significantly (P < 0.00001). Similar results were found for ophthalmic and short posterior ciliary artery EDVs (P= .0003; P< .00001). Ophthalmic artery RI was significantly higher in eyes with retinopathy than controls (P = .0008), with heterogeneity (Pheterogeneity < .00001; I(2) = 84%). In group 3, ophthalmic artery PSV was lower in eyes with retinopathy (P= .04) than eyes without, and central retinal artery PSV and EDV decreased significantly (P = .004; P < .00001) in eyes with retinopathy compared to eyes without. Differences in ophthalmic and central retinal artery RIs were also found in eyes with retinopathy (P = .05; P < .00001). Significant changes in retrobulbar blood flow were found in eyes without and with diabetic retinopathy, especially those with retinopathy. © 2014 by the American Institute of Ultrasound in Medicine.
Blood flow velocity in monocular retinoblastoma assessed by color doppler
Bonanomi, Maria Teresa B C; Saito, Osmar C; de Lima, Patricia Picciarelli; Bonanomi, Roberta Chizzotti; Chammas, Maria Cristina
2015-01-01
OBJECTIVE: To analyze the flow of retrobulbar vessels in retinoblastoma by color Doppler imaging. METHODS: A prospective study of monocular retinoblastoma treated by enucleation between 2010 and 2014. The examination comprised fundoscopy, magnetic resonance imaging, ultrasonography and color Doppler imaging. The peak blood velocities in the central retinal artery and central retinal vein of tumor-containing eyes (tuCRAv and tuCRVv, respectively) were assessed. The velocities were compared with those for normal eyes (nlCRAv and nlCRVv) and correlated with clinical and pathological findings. Tumor dimensions in the pathological sections were compared with those in magnetic resonance imaging and ultrasonography and were correlated with tuCRAv and tuCRVv. In tumor-containing eyes, the resistivity index in the central retinal artery and the pulse index in the central retinal vein were studied in relation to all variables. RESULTS: Eighteen patients were included. Comparisons between tuCRAv and nlCRAv and between tuCRVv and nlCRVv revealed higher velocities in tumor-containing eyes (p<0.001 for both), with a greater effect in the central retinal artery than in the central retinal vein (p=0.024). Magnetic resonance imaging and ultrasonography measurements were as reliable as pathology assessments (p=0.675 and p=0.375, respectively). A positive relationship was found between tuCRAv and the tumor volume (p=0.027). The pulse index in the central retinal vein was lower in male patients (p=0.017) and in eyes with optic nerve invasion (p=0.0088). CONCLUSIONS: TuCRAv and tuCRVv are higher in tumor-containing eyes than in normal eyes. Magnetic resonance imaging and ultrasonography measurements are reliable. The tumor volume is correlated with a higher tuCRAv and a reduced pulse in the central retinal vein is correlated with male sex and optic nerve invasion. PMID:26735219
Tenekecioglu, Erhan; Agca, Fahriye Vatansever; Karaagac, Kemal; Ozluk, Ozlem Arican; Peker, Tezcan; Kuzeytemiz, Mustafa; Senturk, Muhammed; Yılmaz, Mustafa
2014-01-01
Abstract The onset of AF results in a significant increase in mortality rates and morbidity in hypertensive patients and this rhythm disorder exposes patients to a significantly increased risk of cerebral or peripheral embolisms. Tissue Doppler imaging was found to be useful in early detection of myocardial dysfunction in several diseases. It was shown that tissue Doppler analysis of the walls of the left atrial appendage (LAA) can give accurate information about the function of the LAA in hypertensive patients. In this study, we aimed to investigate and identify the specific predictive parameters for the onset of AF in patients with hypertension with tissue Doppler imaging of LAA. We studied age and sex matched 57 untreated hypertensive patients with paroxysmal atrial fibrillation (PAF) and 27 untreated hypertensive subjects without PAF. With transthoracic echocardiography, diastolic mitral A-velocity and LA maximal volume index which reflects reservoir function of left atrium was measured, with transesophageal echocardiography, LAA emptying velocity (LAA-PW D2) and tissue Doppler contracting velocity of LAA (LAA-TDI-D2) were measured. LA maximal volume index of the groups (22.28 ± 3.59 mL/m(2) in Group 1 versus 20.37 ± 3.97 mL/m(2) in Group 2, p = 0.07) and diastolic mitral A-velocity [0.93 (0.59-1.84) m/s in patients with PAF versus 0.90 (0.62-1.76) m/s in patients without PAF, p = 0.26] was not significantly different between study groups, during TEE, LAA-PW D2 (0.31 ± 0.04 m/s in Group 1 versus 0.33 ± 0.03 m/s in Group 2, p = 0.034) and LAA-TDI-D2 (0.18 ± 0.04 m/s in Group 1 versus 0.21 ± 0.05 m/s in Group 2, p = 0.014) were significantly decreased in Group 1. In this study, we found that in hypertensive PAF patients despite normal global LA functions, LAA contracting function was deteriorated. Tissue Doppler analysis of LAA is clinically usefull approach to detect the risk of developing PAF in hypertensives.
NASA Astrophysics Data System (ADS)
You, Minli; Lin, Min; Wang, Shurui; Wang, Xuemin; Zhang, Ge; Hong, Yuan; Dong, Yuqing; Jin, Guorui; Xu, Feng
2016-05-01
Medicine counterfeiting is a serious issue worldwide, involving potentially devastating health repercussions. Advanced anti-counterfeit technology for drugs has therefore aroused intensive interest. However, existing anti-counterfeit technologies are associated with drawbacks such as the high cost, complex fabrication process, sophisticated operation and incapability in authenticating drug ingredients. In this contribution, we developed a smart phone recognition based upconversion fluorescent three-dimensional (3D) quick response (QR) code for tracking and anti-counterfeiting of drugs. We firstly formulated three colored inks incorporating upconversion nanoparticles with RGB (i.e., red, green and blue) emission colors. Using a modified inkjet printer, we printed a series of colors by precisely regulating the overlap of these three inks. Meanwhile, we developed a multilayer printing and splitting technology, which significantly increases the information storage capacity per unit area. As an example, we directly printed the upconversion fluorescent 3D QR code on the surface of drug capsules. The 3D QR code consisted of three different color layers with each layer encoded by information of different aspects of the drug. A smart phone APP was designed to decode the multicolor 3D QR code, providing the authenticity and related information of drugs. The developed technology possesses merits in terms of low cost, ease of operation, high throughput and high information capacity, thus holds great potential for drug anti-counterfeiting.Medicine counterfeiting is a serious issue worldwide, involving potentially devastating health repercussions. Advanced anti-counterfeit technology for drugs has therefore aroused intensive interest. However, existing anti-counterfeit technologies are associated with drawbacks such as the high cost, complex fabrication process, sophisticated operation and incapability in authenticating drug ingredients. In this contribution, we developed a smart phone recognition based upconversion fluorescent three-dimensional (3D) quick response (QR) code for tracking and anti-counterfeiting of drugs. We firstly formulated three colored inks incorporating upconversion nanoparticles with RGB (i.e., red, green and blue) emission colors. Using a modified inkjet printer, we printed a series of colors by precisely regulating the overlap of these three inks. Meanwhile, we developed a multilayer printing and splitting technology, which significantly increases the information storage capacity per unit area. As an example, we directly printed the upconversion fluorescent 3D QR code on the surface of drug capsules. The 3D QR code consisted of three different color layers with each layer encoded by information of different aspects of the drug. A smart phone APP was designed to decode the multicolor 3D QR code, providing the authenticity and related information of drugs. The developed technology possesses merits in terms of low cost, ease of operation, high throughput and high information capacity, thus holds great potential for drug anti-counterfeiting. Electronic supplementary information (ESI) available: Calculating details of UCNP content per 3D QR code and decoding process of the 3D QR code. See DOI: 10.1039/c6nr01353h
SIGACE Code for Generating High-Temperature ACE Files; Validation and Benchmarking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Amit R.; Ganesan, S.; Trkov, A.
2005-05-24
A code named SIGACE has been developed as a tool for MCNP users within the scope of a research contract awarded by the Nuclear Data Section of the International Atomic Energy Agency (IAEA) (Ref: 302-F4-IND-11566 B5-IND-29641). A new recipe has been evolved for generating high-temperature ACE files for use with the MCNP code. Under this scheme the low-temperature ACE file is first converted to an ENDF formatted file using the ACELST code and then Doppler broadened, essentially limited to the data in the resolved resonance region, to any desired higher temperature using SIGMA1. The SIGACE code then generates a high-temperaturemore » ACE file for use with the MCNP code. A thinning routine has also been introduced in the SIGACE code for reducing the size of the ACE files. The SIGACE code and the recipe for generating ACE files at higher temperatures has been applied to the SEFOR fast reactor benchmark problem (sodium-cooled fast reactor benchmark described in ENDF-202/BNL-19302, 1974 document). The calculated Doppler coefficient is in good agreement with the experimental value. A similar calculation using ACE files generated directly with the NJOY system also agrees with our SIGACE computed results. The SIGACE code and the recipe is further applied to study the numerical benchmark configuration of selected idealized PWR pin cell configurations with five different fuel enrichments as reported by Mosteller and Eisenhart. The SIGACE code that has been tested with several FENDL/MC files will be available, free of cost, upon request, from the Nuclear Data Section of the IAEA.« less
Barbier, Paolo; Alimento, Marina; Berna, Giovanni; Celeste, Fabrizio; Gentile, Francesco; Mantero, Antonio; Montericcio, Vincenzo; Muratori, Manuela
2007-05-01
Large files produced by standard compression algorithms slow down spread of digital and tele-echocardiography. We validated echocardiographic video high-grade compression with the new Motion Pictures Expert Groups (MPEG)-4 algorithms with a multicenter study. Seven expert cardiologists blindly scored (5-point scale) 165 uncompressed and compressed 2-dimensional and color Doppler video clips, based on combined diagnostic content and image quality (uncompressed files as references). One digital video and 3 MPEG-4 algorithms (WM9, MV2, and DivX) were used, the latter at 3 compression levels (0%, 35%, and 60%). Compressed file sizes decreased from 12 to 83 MB to 0.03 to 2.3 MB (1:1051-1:26 reduction ratios). Mean SD of differences was 0.81 for intraobserver variability (uncompressed and digital video files). Compared with uncompressed files, only the DivX mean score at 35% (P = .04) and 60% (P = .001) compression was significantly reduced. At subcategory analysis, these differences were still significant for gray-scale and fundamental imaging but not for color or second harmonic tissue imaging. Original image quality, session sequence, compression grade, and bitrate were all independent determinants of mean score. Our study supports use of MPEG-4 algorithms to greatly reduce echocardiographic file sizes, thus facilitating archiving and transmission. Quality evaluation studies should account for the many independent variables that affect image quality grading.
Ivanovski, M; Damcevski, N; Radevska, B; Doicev, G
2012-01-01
To investigate whether success rates of IVF/ICSI could be predicted by using the Color Doppler technique by measuring the uterine artery and arcuate artery pulsatility (PI), resistance (RI), and velocity (Vs) indices on the day of hCG injection. This was a prospective observational study at the St Lazar Hospital, Skopje; 106 patients with an indication for IVF or ICSI according to departmental protocol underwent controlled ovarian hyperstimulation followed by IVF/ICSI and embryo transfer. Using Color Doppler in the two-dimensional (2D) mode, flow velocity waveforms were obtained from the ascending main branch of the uterine artery on the right and left sides of the cervix in a longitudinal plane and arcuate arteries, before they entered the uterus. The PI, RI and peak systolic velocity (PSV) of the uterine arteries and arcuate arteries were calculated electronically when similar consecutive waveforms of good quality were obtained and results were compared between patients who conceived and those who did not. In total, 106 patients, aged 24-42 years were included in the study. The patients were divided into two groups according to successful outcome, defined as pregnancy and failure of implantation, where no pregnancy was detected. A total of 40 pregnancies resulted; a crude pregnancy rate was 40/106 (37.7%). There were no significant differences between either group in patients' age, type and duration of infertility; basal levels of FSH, LH and E2; number of gonadotropin ampoules used for ovulation induction; number of retrieved oocytes and number of transferred embryos. No cycle was canceled after initiation of gonadotropin stimulation. In our results, there were statistically significant lower mean uterine artery PI and RI in the pregnant group than in the non-pregnant group (P < 0.05). Arcuate artery PI value was lower in the pregnant group than in the non-pregnant group, but this did not reach statistical significance. Peak systolic velocity (Vs) values in both the mean uterine artery and arcuate artery were higher in the pregnant group than in the non-pregnant group; however, the difference was not statistically significant. Vascular impedance was calculated with PI, RI, and Vs values, among which PI was found to be the most important. Optimal uterine receptivity can be accomplished by reduced vascular resistance and increased blood flow, which will improve pregnancy success. We suggest the use of transvaginal color Doppler ultrasonography to measure the blood flow in uterine arteries and arcuate arteries before hCG in IVF cycles.
Effects of Gender Color-Coding on Toddlers' Gender-Typical Toy Play.
Wong, Wang I; Hines, Melissa
2015-07-01
Gender color-coding of children's toys may make certain toys more appealing or less appealing to a given gender. We observed toddlers playing with two gender-typical toys (a train, a doll), once in gender-typical colors and once in gender-atypical colors. Assessments occurred twice, at 20-40 months of age and at 26-47 months of age. A Sex × Time × Toy × Color ANOVA showed expected interactions between Sex and Toy and Sex and Color. Boys played more with the train than girls did and girls played more with the doll and with pink toys than boys did. The Sex × Toy × Color interaction was not significant, but, at both time points, boys and girls combined played more with the gender-atypical toy when its color was typical for their sex than when it was not. This effect appeared to be caused largely by boys' preference for, or avoidance of, the doll and by the use of pink. Also, at both time points, gender differences in toy preferences were larger in the gender-typical than in the gender-atypical color condition. At Time 2, these gender differences were present only in the gender-typical color condition. Overall, the results suggest that, once acquired, gender-typical color preferences begin to influence toy preferences, especially those for gender-atypical toys and particularly in boys. They thus could enlarge differences between boys' and girls' toy preferences. Because boys' and girls' toys elicit different activities, removing the gender color-coding of toys could encourage more equal learning opportunities.
NASA Astrophysics Data System (ADS)
Litinski, Daniel; Kesselring, Markus S.; Eisert, Jens; von Oppen, Felix
2017-07-01
We present a scalable architecture for fault-tolerant topological quantum computation using networks of voltage-controlled Majorana Cooper pair boxes and topological color codes for error correction. Color codes have a set of transversal gates which coincides with the set of topologically protected gates in Majorana-based systems, namely, the Clifford gates. In this way, we establish color codes as providing a natural setting in which advantages offered by topological hardware can be combined with those arising from topological error-correcting software for full-fledged fault-tolerant quantum computing. We provide a complete description of our architecture, including the underlying physical ingredients. We start by showing that in topological superconductor networks, hexagonal cells can be employed to serve as physical qubits for universal quantum computation, and we present protocols for realizing topologically protected Clifford gates. These hexagonal-cell qubits allow for a direct implementation of open-boundary color codes with ancilla-free syndrome read-out and logical T gates via magic-state distillation. For concreteness, we describe how the necessary operations can be implemented using networks of Majorana Cooper pair boxes, and we give a feasibility estimate for error correction in this architecture. Our approach is motivated by nanowire-based networks of topological superconductors, but it could also be realized in alternative settings such as quantum-Hall-superconductor hybrids.
Tumor tissue characterization using polarization-sensitive second harmonic generation microscopy
NASA Astrophysics Data System (ADS)
Tokarz, Danielle; Cisek, Richard; Golaraei, Ahmad; Krouglov, Serguei; Navab, Roya; Niu, Carolyn; Sakashita, Shingo; Yasufuku, Kazuhiro; Tsao, Ming-Sound; Asa, Sylvia L.; Barzda, Virginijus; Wilson, Brian C.
2015-06-01
Changes in the ultrastructure of collagen in various tumor and non-tumor human tissues including lung, pancreas and thyroid were investigated ex vivo by a polarization-sensitive second harmonic generation (SHG) microscopy technique referred to as polarization-in, polarization-out (PIPO) SHG. This involves measuring the orientation of the linear polarization of outgoing SHG as a function of the linear polarization orientation of incident laser radiation. From the PIPO SHG data, the second-order nonlinear optical susceptibility tensor component ratio, χ(2) ZZZ'/χ(2) ZXX', for each pixel of the SHG image was obtained and presented as color-coded maps. Further, the orientation of collagen fibers in the tissue was deduced. Since the χ(2) ZZZ'/χ(2) ZXX' values represent the organization of collagen in the tissue, theses maps revealed areas of altered collagen structure (not simply concentration) within tissue sections. Statistically-significant differences in χ(2) ZZZ'/χ(2) ZXX' were found between tumor and non-tumor tissues, which varied from organ to organ. Hence, PIPO SHG microscopy could potentially be used to aid pathologists in diagnosing cancer. Additionally, PIPO SHG microscopy could aid in characterizing the structure of collagen in other collagen-related biological processes such as wound repair.
The MOST - Monitor for Oxygenation of Surface and Tissue.
1995-10-01
CAT Reduce need for ICU, low risk groups Central nursing station Office procedures: Dentistry , Endoscopy Monitoring spinal or epidural narcotics Home...obtainable by using laser Doppler methods (Wickramasinghe et al., 1994; Liepsch et al., 1993; Mendelson, Ochs, 1988). While many parameters beyond oxygenation...blood flow include laser Doppler flowmetry sys- tems which are currently commercially available. These systems measure the velocity of blood particles
Pseudo-color coding method for high-dynamic single-polarization SAR images
NASA Astrophysics Data System (ADS)
Feng, Zicheng; Liu, Xiaolin; Pei, Bingzhi
2018-04-01
A raw synthetic aperture radar (SAR) image usually has a 16-bit or higher bit depth, which cannot be directly visualized on 8-bit displays. In this study, we propose a pseudo-color coding method for high-dynamic singlepolarization SAR images. The method considers the characteristics of both SAR images and human perception. In HSI (hue, saturation and intensity) color space, the method carries out high-dynamic range tone mapping and pseudo-color processing simultaneously in order to avoid loss of details and to improve object identifiability. It is a highly efficient global algorithm.
Keep It Simple. Teaching Tips for Special Olympic Athletes.
ERIC Educational Resources Information Center
Johnston, Judith E.; And Others
1996-01-01
Physical educators can help Special Olympics athletes learn cross-lateral delivery techniques for bowling or throwing softballs by color coding the throwing arm and opposing foot. The article explains color coding, presenting teaching tips for both sports. A series of workshops on modifying exercise principles for individuals with physical…
Use of color-coded sleeve shutters accelerates oscillograph channel selection
NASA Technical Reports Server (NTRS)
Bouchlas, T.; Bowden, F. W.
1967-01-01
Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.
Color Coding of Circuit Quantities in Introductory Circuit Analysis Instruction
ERIC Educational Resources Information Center
Reisslein, Jana; Johnson, Amy M.; Reisslein, Martin
2015-01-01
Learning the analysis of electrical circuits represented by circuit diagrams is often challenging for novice students. An open research question in electrical circuit analysis instruction is whether color coding of the mathematical symbols (variables) that denote electrical quantities can improve circuit analysis learning. The present study…
Transdural doppler ultrasonography monitors cerebral blood flow changes in relation to motor tasks.
Hatanaka, Nobuhiko; Tokuno, Hironobu; Nambu, Atsushi; Takada, Masahiko
2009-04-01
Monitoring changes in cerebral blood flow in association with neuronal activity has widely been used to evaluate various brain functions. However, current techniques do not directly measure blood flow changes in specified blood vessels. The present study identified arterioles within the cerebral cortex by echoencephalography and color Doppler imaging, and then measured blood flow velocity (BFV) changes in pulsed-wave Doppler mode. We applied this "transdural Doppler ultrasonography (TDD)" to examine BFV changes in the cortical motor-related areas of monkeys during the performance of unimanual (right or left) and bimanual key-press tasks. BFV in the primary motor cortex (MI) was increased in response to contralateral movement. In each of the unimanual and bimanual tasks, bimodal BFV increases related to both the instruction signal and the movement were observed in the supplementary motor area (SMA). Such BFV changes in the SMA were prominent during the early stage of task training and gradually decreased with improvements in task performance, leaving those in the MI unchanged. Moreover, BFV changes in the SMA depended on task difficulty. The present results indicate that TDD is useful for evaluating regional brain functions.
NASA Astrophysics Data System (ADS)
Keller, Brad M.; Gastounioti, Aimilia; Batiste, Rebecca C.; Kontos, Despina; Feldman, Michael D.
2016-03-01
Visual characterization of histologic specimens is known to suffer from intra- and inter-observer variability. To help address this, we developed an automated framework for characterizing digitized histology specimens based on a novel application of color histogram and color texture analysis. We perform a preliminary evaluation of this framework using a set of 73 trichrome-stained, digitized slides of normal breast tissue which were visually assessed by an expert pathologist in terms of the percentage of collagenous stroma, stromal collagen density, duct-lobular unit density and the presence of elastosis. For each slide, our algorithm automatically segments the tissue region based on the lightness channel in CIELAB colorspace. Within each tissue region, a color histogram feature vector is extracted using a common color palette for trichrome images generated with a previously described method. Then, using a whole-slide, lattice-based methodology, color texture maps are generated using a set of color co-occurrence matrix statistics: contrast, correlation, energy and homogeneity. The extracted features sets are compared to the visually assessed tissue characteristics. Overall, the extracted texture features have high correlations to both the percentage of collagenous stroma (r=0.95, p<0.001) and duct-lobular unit density (r=0.71, p<0.001) seen in the tissue samples, and several individual features were associated with either collagen density and/or the presence of elastosis (p<=0.05). This suggests that the proposed framework has promise as a means to quantitatively extract descriptors reflecting tissue-level characteristics and thus could be useful in detecting and characterizing histological processes in digitized histology specimens.
Error threshold for color codes and random three-body Ising models.
Katzgraber, Helmut G; Bombin, H; Martin-Delgado, M A
2009-08-28
We study the error threshold of color codes, a class of topological quantum codes that allow a direct implementation of quantum Clifford gates suitable for entanglement distillation, teleportation, and fault-tolerant quantum computation. We map the error-correction process onto a statistical mechanical random three-body Ising model and study its phase diagram via Monte Carlo simulations. The obtained error threshold of p(c) = 0.109(2) is very close to that of Kitaev's toric code, showing that enhanced computational capabilities do not necessarily imply lower resistance to noise.
Kumar, Vipin; Jose, John; Jose, V Jacob
2014-01-01
62-year-old female presented with progressive dyspnea NYHA class III for six months. Echocardiography showed normal left ventricular (LV) systolic function, mild biatrial enlargement, an L wave in pulse wave Doppler at mitral inflow and in M mode echocardiography across mitral valve. Tissue Doppler imaging at medial mitral annulus showed an L' wave in mid diastole in addition to E' and A' wave. An L wave in pulse wave Doppler and M mode echocardiography represents continued pulmonary vein mid diastolic flow through the left atrium in to LV across mitral valve after early rapid filling. Presence of an L' wave in these patients associated with higher E/E' is indicative of advance diastolic dysfunction with elevated filling pressures. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Color-Blindness Study: Color Discrimination on the TICCIT System.
ERIC Educational Resources Information Center
Asay, Calvin S.; Schneider, Edward W.
The question studied whether the specific seven TICCIT system colors used within color coding schemes can be a source of confusion, or not seen at all, by the color-blind segment of target populations. Subjects were 11 color-blind and three normally sighted students at Brigham Young University. After a preliminary training exercise to acquaint the…
Pinter, Stephen Z; Kim, Dae-Ro; Hague, M Nicole; Chambers, Ann F; MacDonald, Ian C; Lacefield, James C
2014-08-01
Flow quantification with high-frequency (>20 MHz) power Doppler ultrasound can be performed objectively using the wall-filter selection curve (WFSC) method to select the cutoff velocity that yields a best-estimate color pixel density (CPD). An in vivo video microscopy system (IVVM) is combined with high-frequency power Doppler ultrasound to provide a method for validation of CPD measurements based on WFSCs in mouse testicular vessels. The ultrasound and IVVM systems are instrumented so that the mouse remains on the same imaging platform when switching between the two modalities. In vivo video microscopy provides gold-standard measurements of vascular diameter to validate power Doppler CPD estimates. Measurements in four image planes from three mice exhibit wide variation in the optimal cutoff velocity and indicate that a predetermined cutoff velocity setting can introduce significant errors in studies intended to quantify vascularity. Consistent with previously published flow-phantom data, in vivo WFSCs exhibited three characteristic regions and detectable plateaus. Selection of a cutoff velocity at the right end of the plateau yielded a CPD close to the gold-standard vascular volume fraction estimated using IVVM. An investigator can implement the WFSC method to help adapt cutoff velocity to current blood flow conditions and thereby improve the accuracy of power Doppler for quantitative microvascular imaging. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Burgess, Cheryl M
2007-01-01
In recent years, people of color have become an increasingly important market force for the cosmetics industry. Product lines have been expanded to accommodate a broader spectrum of skin colors and marketing strategies have been specialized in order to target specific ethnic populations. In addition, it is predicted that people with pigmented skin will eventually comprise a majority of the domestic and international population during the 21st century. Not surprisingly, people of color are increasingly seeking out products and procedures to fight the effects of aging, including an increase in surgical and nonsurgical cosmetic procedures. Among nonsurgical procedures, soft tissue augmentation has experienced dramatic growth. Today, clinicians are performing more and more of these procedures in people of color. As a result of these shifts in the cosmetics industry, clinicians performing soft tissue augmentation require increased expertise in the treatment of ethnic skin. This article reviews the important differences that exist between the appearance of the aging faces of Caucasians and people of color. In addition, soft tissue augmentation strategies and injection techniques that are specific to skin of color are discussed.
Human V4 Activity Patterns Predict Behavioral Performance in Imagery of Object Color.
Bannert, Michael M; Bartels, Andreas
2018-04-11
Color is special among basic visual features in that it can form a defining part of objects that are engrained in our memory. Whereas most neuroimaging research on human color vision has focused on responses related to external stimulation, the present study investigated how sensory-driven color vision is linked to subjective color perception induced by object imagery. We recorded fMRI activity in male and female volunteers during viewing of abstract color stimuli that were red, green, or yellow in half of the runs. In the other half we asked them to produce mental images of colored, meaningful objects (such as tomato, grapes, banana) corresponding to the same three color categories. Although physically presented color could be decoded from all retinotopically mapped visual areas, only hV4 allowed predicting colors of imagined objects when classifiers were trained on responses to physical colors. Importantly, only neural signal in hV4 was predictive of behavioral performance in the color judgment task on a trial-by-trial basis. The commonality between neural representations of sensory-driven and imagined object color and the behavioral link to neural representations in hV4 identifies area hV4 as a perceptual hub linking externally triggered color vision with color in self-generated object imagery. SIGNIFICANCE STATEMENT Humans experience color not only when visually exploring the outside world, but also in the absence of visual input, for example when remembering, dreaming, and during imagery. It is not known where neural codes for sensory-driven and internally generated hue converge. In the current study we evoked matching subjective color percepts, one driven by physically presented color stimuli, the other by internally generated color imagery. This allowed us to identify area hV4 as the only site where neural codes of corresponding subjective color perception converged regardless of its origin. Color codes in hV4 also predicted behavioral performance in an imagery task, suggesting it forms a perceptual hub for color perception. Copyright © 2018 the authors 0270-6474/18/383657-12$15.00/0.
Trans-skull ultrasonic Doppler system aided by fuzzy logic
NASA Astrophysics Data System (ADS)
Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto
2012-06-01
This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.
Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh
2015-03-01
Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged <60 years and 18 (43/9%) patients were aged >60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.
Catalano, Orlando; Voit, Christiane; Sandomenico, Fabio; Mandato, Ylenia; Petrillo, Mario; Franco, Renato; Botti, Gerardo; Caracò, Corrado; Mozzillo, Nicola; D'Errico, Adolfo Gallipoli
2011-08-01
Sonography has proven to be a reliable tool in early detection of lymph node and in-transit cutaneous-subcutaneous metastases. Those metastases normally appear as hypoechoic or even anechoic lesions on sonography. It has been assumed that this appearance is due to necrosis of the lesions, but so far, that assumption has never been proven. The purpose of this retrospective study was to evaluate whether the hypoechoic appearance of melanoma metastasis is really due to tumor necrosis. From a radiographic database, we retrieved 212 melanoma cases imaged with sonography over a 2-year period for disease staging or follow-up. We selected 37 positive cases with 84 nodal and extranodal (satellite and in-transit) metastatic lesions and reviewed the sonograms and pathologic slides (slides available for 40 of 84 lesions). We retrospectively assessed the vascularization pattern (color Doppler images available for 78 of 84 lesions), categorizing it as poor, intermediate, or consistent. We also looked for necrosis on the histopathologic material, categorizing it into scores of 0, 1, 2, and 3 for absence of necrosis, less than 20% necrosis, 20% to 40% necrosis, and greater than 40% necrosis, respectively. Despite their gray scale appearance, most melanoma lesions were vascularized on color Doppler imaging and showed limited necrosis at histopathologic analysis. Consistent vascularization on Doppler imaging, excluding substantial necrosis, was found in 44 of 78 lesions (56.4%). Poor vascularization on Doppler imaging, suggesting necrosis, was present in only 14% of the lesions. Substantial necrosis (scores of 2 and 3) was found pathologically in only 10% of the lesions. Necrosis seems to be an uncommon event in melanoma metastasis and is probably not the basis for its low-level echo pattern on sonography. The hypoechoic appearance is very typical of melanoma metastasis and is likely due to massive melanomatous infiltration (with the poor echo reflectivity of melanin). However, confirmation in larger pathologically proven series is required.
A review on color normalization and color deconvolution methods in histopathology.
Onder, Devrim; Zengin, Selen; Sarioglu, Sulen
2014-01-01
The histopathologists get the benefits of wide range of colored dyes to have much useful information about the lesions and the tissue compositions. Despite its advantages, the staining process comes up with quite complex variations in staining concentrations and correlations, tissue fixation types, and fixation time periods. Together with the improvements in computing power and with the development of novel image analysis methods, these imperfections have led to the emerging of several color normalization algorithms. This article is a review of the currently available digital color normalization methods for the bright field histopathology. We describe the proposed color normalization methodologies in detail together with the lesion and tissue types used in the corresponding experiments. We also present the quantitative validation approaches for each of the proposed methodology where available.
NASA Technical Reports Server (NTRS)
Owen, Albert K.
1987-01-01
A computer code was written which utilizes ray tracing techniques to predict the changes in position and geometry of a laser Doppler velocimeter probe volume resulting from refraction effects. The code predicts the position change, changes in beam crossing angle, and the amount of uncrossing that occur when the beams traverse a region with a changed index of refraction, such as a glass window. The code calculates the changes for flat plate, cylinder, general axisymmetric and general surface windows and is currently operational on a VAX 8600 computer system.
ERIC Educational Resources Information Center
Antarasena, Salinee
2009-01-01
This study investigates teaching methods regarding color comprehension and color categorization among blind students, as compared to their non-blind peers and whether they understand and represent the same color comprehension and color categories. Then after digit codes for color comprehension teaching and assistive technology for the blind had…
Yuksel, Isa Oner; Akar Bayram, Nihal; Koklu, Erkan; Ureyen, Cagin Mustafa; Kucukseymen, Selcuk; Arslan, Sakir; Bozkurt, Engin
2016-06-01
In our study, we aimed to evaluate the effect of weight loss on left and right ventricular functions in obese patients. Thirty patients with a BMI greater than 30 kg/m(2) and without any exclusion criteria were included in the study. Left ventricular systolic and diastolic functions were assessed with conventional and tissue Doppler echocardiography (TDE). At the end of 3 months, echocardiographic examination was repeated in patients with weight loss for cardiac function evaluation and it was compared to the baseline echocardiographic parameters. At the end of 3 months of weight loss period, conventional Doppler echocardiography revealed an improvement in diastolic functions with an increase in mitral E-wave, a decrease in mitral A-wave and an increase in E/A ratio. Deceleration time and isovolumetric relaxation time were ascertained shortened and Tei index decreased. TDE showed an increase in left ventricular lateral wall systolic wave (Sm) and E-wave velocity (Em). Mitral septal annular isovolumetric acceleration time (IVA), Sm and Em, were found to be increased, whereas Tei index was ascertained reduced. Right ventricular tissue Doppler examination following weight loss revealed an increase in RV- IVA, RV-Sm, and RV-Em, and a decrease in Tei index. We disclosed that left ventricular structural changes and diastolic dysfunction occur in obese patients, and by weight loss, these abnormalities may be reversible which we demonstrated both by conventional and TDE. In addition, obesity might impair RV function as well, and we observed an enhancement in right ventricular functions by weight loss. © 2016, Wiley Periodicals, Inc.
Wind turbine generators with active radar signature control blades
NASA Astrophysics Data System (ADS)
Tennant, Alan; Chambers, Barry
2004-07-01
The large radar cross section of wind turbine generator (WTG) blades combined with high tip speeds can produce significant Doppler returns when illuminated by a radar. Normally, an air traffic control radar system will filter out large returns from stationary targets, however the Doppler shifts introduced by the WTG are interpreted as moving aircraft that can confuse radar operators and compromise safety. A possible solution to this problem that we are investigating is to incorporate an active layer into the structure of the WTG blades that can be used to dynamically modulate the RCS of the blade return. The active blade can operate in one of two modes: firstly the blade RCS can be modulated to provide a Doppler return that is outside the detectable range of the radar receiver system so that it is rejected: a second mode of operation is to introduce specific coding on to the Doppler returns so that they may be uniquely identified and rejected. The active layer used in the system consists of a frequency selective surface controlled by semiconductor diodes and is a development of techniques that we have developed for active radar absorbers. Results of experimental work using a 10GHz Doppler radar and scale model WTG with active Doppler imparting blades are presented.
Liao, Ai-Ho; Chung, Huan-Yu; Chen, Wen-Shiang; Yeh, Ming-Kung
2016-08-01
A previous study that investigated the effect of ultrasound (US) on the transdermal permeation of the non-steroidal anti-inflammatory drug diclofenac found that therapeutic US can increase circulation in an inflamed joint and decrease arthritic pain. Transdermal drug delivery has recently been demonstrated by US combined with microbubbles (MB) contrast agent (henceforth referred to as "US-MB"). The present study evaluated the efficacy of US-MB-mediated diclofenac delivery for treating adjuvant-induced rheumatoid arthritis (RA) in rats. RA was induced by injecting 100 μL of complete Freund's adjuvant into the ankle joint of male Sprague-Dawley rats (250-300 g) that were randomly divided into five treatment groups: (i) carbopol gel alone (the control [group C]), (ii) diclofenac-carbopol gel (group D), (iii) US plus carbopol gel (group U), (iv) US plus diclofenac-carbopol gel (group DU) and (v) US-MB plus diclofenac-carbopol gel (group DUB). The ankle width was measured over 10 d using high-frequency (40-MHz) US B-mode and color Doppler-mode imaging, covering the period before and after treatment. Longitudinal US images of the induced RA showed synovitis and neovascularity. Only a small amount of neovascularity was observed after treatment. The recovery rate on day 10 was significantly higher in group DUB (97.7% ± 2.7%, mean ± standard deviation [SD]) than in groups C (1.0% ± 2.7%), D (37.5% ± 4.6%), U (75.5% ± 4.2%) and DU (87.3% ± 5.2%) (p < 0.05). The results obtained indicate that combining US and MB can increase the skin permeability and thereby enhance the delivery of diclofenac sodium gel and thereby inhibit inflammation of the tissues surrounding the arthritic ankle. Color Doppler-mode imaging revealed that US-MB treatment induced a rapid reduction in synovial neoangiogenesis in the arthritic area. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Anderson, B. H.; Putt, C. W.; Giamati, C. C.
1981-01-01
Color coding techniques used in the processing of remote sensing imagery were adapted and applied to the fluid dynamics problems associated with turbofan mixer nozzles. The computer generated color graphics were found to be useful in reconstructing the measured flow field from low resolution experimental data to give more physical meaning to this information and in scanning and interpreting the large volume of computer generated data from the three dimensional viscous computer code used in the analysis.
Compression of color-mapped images
NASA Technical Reports Server (NTRS)
Hadenfeldt, A. C.; Sayood, Khalid
1992-01-01
In a standard image coding scenario, pixel-to-pixel correlation nearly always exists in the data, especially if the image is a natural scene. This correlation is what allows predictive coding schemes (e.g., DPCM) to perform efficient compression. In a color-mapped image, the values stored in the pixel array are no longer directly related to the pixel intensity. Two color indices which are numerically adjacent (close) may point to two very different colors. The correlation still exists, but only via the colormap. This fact can be exploited by sorting the color map to reintroduce the structure. The sorting of colormaps is studied and it is shown how the resulting structure can be used in both lossless and lossy compression of images.
Tissue Doppler and strain imaging: anything left in the echo-lab?
Citro, Rodolfo; Bossone, Eduardo; Kuersten, Bettina; Gregorio, Giovanni; Salustri, Alessandro
2008-01-01
Medline research indicates that an increasing number of manuscripts have been published in the last decade claiming, the feasibility and the potential clinical role of tissue Doppler and strain/strain rate imaging. However, despite this amount of scientific evidence, these technologies are still confined to dedicated, high-tech, research-oriented echocardiography laboratories. In this review we have critically evaluated these techniques, analysing their physical principles, the technical problems related to their current clinical application, and the future perspectives. Finally, this review explores the reasons why these technologies are still defined "new technologies" and the impact of their implementation on the current clinical activity of an echocardiography laboratory. PMID:18973677
NASA Astrophysics Data System (ADS)
Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.
2016-04-01
Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.
Faurie, Julia; Baudet, Mathilde; Assi, Kondo Claude; Auger, Dominique; Gilbert, Guillaume; Tournoux, Francois; Garcia, Damien
2017-02-01
Recent studies have suggested that intracardiac vortex flow imaging could be of clinical interest to early diagnose the diastolic heart function. Doppler vortography has been introduced as a simple color Doppler method to detect and quantify intraventricular vortices. This method is able to locate a vortex core based on the recognition of an antisymmetric pattern in the Doppler velocity field. Because the heart is a fast-moving organ, high frame rates are needed to decipher the whole blood vortex dynamics during diastole. In this paper, we adapted the vortography method to high-frame-rate echocardiography using circular waves. Time-resolved Doppler vortography was first validated in vitro in an ideal forced vortex. We observed a strong correlation between the core vorticity determined by high-frame-rate vortography and the ground-truth vorticity. Vortography was also tested in vivo in ten healthy volunteers using high-frame-rate duplex ultrasonography. The main vortex that forms during left ventricular filling was tracked during two-three successive cardiac cycles, and its core vorticity was determined at a sampling rate up to 80 duplex images per heartbeat. Three echocardiographic apical views were evaluated. Vortography-derived vorticities were compared with those returned by the 2-D vector flow mapping approach. Comparison with 4-D flow magnetic resonance imaging was also performed in four of the ten volunteers. Strong intermethod agreements were observed when determining the peak vorticity during early filling. It is concluded that high-frame-rate Doppler vortography can accurately investigate the diastolic vortex dynamics.
NASA Technical Reports Server (NTRS)
1972-01-01
System studies, equipment simulation, hardware development and flight tests which were conducted during the development of aircraft collision hazard warning system are discussed. The system uses a cooperative, continuous wave Doppler radar principle with pseudo-random frequency modulation. The report presents a description of the system operation and deals at length with the use of pseudo-random coding techniques. In addition, the use of mathematical modeling and computer simulation to determine the alarm statistics and system saturation characteristics in terminal area traffic of variable density is discussed.
Doppler optical coherence tomography of retinal circulation.
Tan, Ou; Wang, Yimin; Konduru, Ranjith K; Zhang, Xinbo; Sadda, SriniVas R; Huang, David
2012-09-18
Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can be calculated. The standard clinical protocol calls for 3 CDCS scans made with the OCT beam passing through the superonasal edge of the pupil and 3 CDCS scan through the inferonal pupil. This double-angle protocol ensures that acceptable Doppler angle is obtained on each retinal branch vessel in at least 1 scan. The CDCS scan data, a 3-dimensional volumetric OCT scan of the optic disc scan, and a color photograph of the optic disc are used together to obtain retinal blood flow measurement on an eye. We have developed a blood flow measurement software called "Doppler optical coherence tomography of retinal circulation" (DOCTORC). This semi-automated software is used to measure total retinal blood flow, vessel cross section area, and average blood velocity. The flow of each vessel is calculated from the Doppler shift in the vessel cross-sectional area and the Doppler angle between the vessel and the OCT beam. Total retinal blood flow measurement is summed from the veins around the optic disc. The results obtained at our Doppler OCT reading center showed good reproducibility between graders and methods (<10%). Total retinal blood flow could be useful in the management of glaucoma, other retinal diseases, and retinal diseases. In glaucoma patients, OCT retinal blood flow measurement was highly correlated with visual field loss (R(2)>0.57 with visual field pattern deviation). Doppler OCT is a new method to perform rapid, noncontact, and repeatable measurement of total retinal blood flow using widely available Fourier-domain OCT instrumentation. This new technology may improve the practicality of making these measurements in clinical studies and routine clinical practice.
Accessible and informative sectioned images, color-coded images, and surface models of the ear.
Park, Hyo Seok; Chung, Min Suk; Shin, Dong Sun; Jung, Yong Wook; Park, Jin Seo
2013-08-01
In our previous research, we created state-of-the-art sectioned images, color-coded images, and surface models of the human ear. Our ear data would be more beneficial and informative if they were more easily accessible. Therefore, the purpose of this study was to distribute the browsing software and the PDF file in which ear images are to be readily obtainable and freely explored. Another goal was to inform other researchers of our methods for establishing the browsing software and the PDF file. To achieve this, sectioned images and color-coded images of ear were prepared (voxel size 0.1 mm). In the color-coded images, structures related to hearing, equilibrium, and structures originated from the first and second pharyngeal arches were segmented supplementarily. The sectioned and color-coded images of right ear were added to the browsing software, which displayed the images serially along with structure names. The surface models were reconstructed to be combined into the PDF file where they could be freely manipulated. Using the browsing software and PDF file, sectional and three-dimensional shapes of ear structures could be comprehended in detail. Furthermore, using the PDF file, clinical knowledge could be identified through virtual otoscopy. Therefore, the presented educational tools will be helpful to medical students and otologists by improving their knowledge of ear anatomy. The browsing software and PDF file can be downloaded without charge and registration at our homepage (http://anatomy.dongguk.ac.kr/ear/). Copyright © 2013 Wiley Periodicals, Inc.
Chromatic aberration and the roles of double-opponent and color-luminance neurons in color vision.
Vladusich, Tony
2007-03-01
How does the visual cortex encode color? I summarize a theory in which cortical double-opponent color neurons perform a role in color constancy and a complementary set of color-luminance neurons function to selectively correct for color fringes induced by chromatic aberration in the eye. The theory may help to resolve an ongoing debate concerning the functional properties of cortical receptive fields involved in color coding.
Anodizing color coded anodized Ti6Al4V medical devices for increasing bone cell functions
Ross, Alexandra P; Webster, Thomas J
2013-01-01
Current titanium-based implants are often anodized in sulfuric acid (H2SO4) for color coding purposes. However, a crucial parameter in selecting the material for an orthopedic implant is the degree to which it will integrate into the surrounding bone. Loosening at the bone–implant interface can cause catastrophic failure when motion occurs between the implant and the surrounding bone. Recently, a different anodization process using hydrofluoric acid has been shown to increase bone growth on commercially pure titanium and titanium alloys through the creation of nanotubes. The objective of this study was to compare, for the first time, the influence of anodizing a titanium alloy medical device in sulfuric acid for color coding purposes, as is done in the orthopedic implant industry, followed by anodizing the device in hydrofluoric acid to implement nanotubes. Specifically, Ti6Al4V model implant samples were anodized first with sulfuric acid to create color-coding features, and then with hydrofluoric acid to implement surface features to enhance osteoblast functions. The material surfaces were characterized by visual inspection, scanning electron microscopy, contact angle measurements, and energy dispersive spectroscopy. Human osteoblasts were seeded onto the samples for a series of time points and were measured for adhesion and proliferation. After 1 and 2 weeks, the levels of alkaline phosphatase activity and calcium deposition were measured to assess the long-term differentiation of osteoblasts into the calcium depositing cells. The results showed that anodizing in hydrofluoric acid after anodizing in sulfuric acid partially retains color coding and creates unique surface features to increase osteoblast adhesion, proliferation, alkaline phosphatase activity, and calcium deposition. In this manner, this study provides a viable method to anodize an already color coded, anodized titanium alloy to potentially increase bone growth for numerous implant applications. PMID:23319862
Seemann, M D; Claussen, C D
2001-06-01
A hybrid rendering method which combines a color-coded surface rendering method and a volume rendering method is described, which enables virtual endoscopic examinations using different representation models. 14 patients with malignancies of the lung and mediastinum (n=11) and lung transplantation (n=3) underwent thin-section spiral computed tomography. The tracheobronchial system and anatomical and pathological features of the chest were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures. For the virtual endoscopy of the tracheobronchial system, a shaded-surface model without color coding, a transparent color-coded shaded-surface model and a triangle-surface model were tested and compared. The hybrid rendering technique exploit the advantages of both rendering methods, provides an excellent overview of the tracheobronchial system and allows a clear depiction of the complex spatial relationships of anatomical and pathological features. Virtual bronchoscopy with a transparent color-coded shaded-surface model allows both a simultaneous visualization of an airway, an airway lesion and mediastinal structures and a quantitative assessment of the spatial relationship between these structures, thus improving confidence in the diagnosis of endotracheal and endobronchial diseases. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images. Virtual bronchoscopy with a transparent color-coded shaded-surface model offers a practical alternative to fiberoptic bronchoscopy and is particularly promising for patients in whom fiberoptic bronchoscopy is not feasible, contraindicated or refused. Furthermore, it can be used as a complementary procedure to fiberoptic bronchoscopy in evaluating airway stenosis and guiding bronchoscopic biopsy, surgical intervention and palliative therapy and is likely to be increasingly accepted as a screening method for people with suspected endobronchial malignancy and as control examination in the aftercare of patients with malignant diseases.
Addetia, Karima; Mor-Avi, Victor; Weinert, Lynn; Salgo, Ivan S; Lang, Roberto M
2014-01-01
Differentiating between mitral valve (MV) prolapse (MVP) and MV billowing (MVB) on two-dimensional echocardiography is challenging. The aim of this study was to test the hypothesis that color-coded models of maximal leaflet displacement from the annular plane into the atrium derived from three-dimensional transesophageal echocardiography would allow discrimination between these lesions. Three-dimensional transesophageal echocardiographic imaging of the MV was performed in 50 patients with (n = 38) and without (n = 12) degenerative MV disease. Definitive diagnosis of MVP versus MVB was made using inspection of dynamic three-dimensional renderings and multiple two-dimensional cut planes extracted from three-dimensional data sets. This was used as a reference standard to test an alternative approach, wherein the color-coded parametric models were inspected for integrity of the coaptation line and location of the maximally displaced portion of the leaflet. Diagnostic interpretations of these models by two independent readers were compared with the reference standard. In all cases of MVP, the color-coded models depicted loss of integrity of the coaptation line and maximal leaflet displacement extending to the coaptation line. MVB was depicted by preserved leaflet apposition with maximal displacement away from the coaptation line. Interpretation of the 50 color-coded models by novice readers took 5 to 10 min and resulted in good agreement with the reference technique (κ = 0.81 and κ = 0.73 for the two readers). Three-dimensional color-coded models provide a static display of MV leaflet displacement, allowing differentiation between MVP and MVB, without the need to inspect multiple planes and while taking into account the saddle shape of the mitral annulus. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Anodizing color coded anodized Ti6Al4V medical devices for increasing bone cell functions.
Ross, Alexandra P; Webster, Thomas J
2013-01-01
Current titanium-based implants are often anodized in sulfuric acid (H(2)SO(4)) for color coding purposes. However, a crucial parameter in selecting the material for an orthopedic implant is the degree to which it will integrate into the surrounding bone. Loosening at the bone-implant interface can cause catastrophic failure when motion occurs between the implant and the surrounding bone. Recently, a different anodization process using hydrofluoric acid has been shown to increase bone growth on commercially pure titanium and titanium alloys through the creation of nanotubes. The objective of this study was to compare, for the first time, the influence of anodizing a titanium alloy medical device in sulfuric acid for color coding purposes, as is done in the orthopedic implant industry, followed by anodizing the device in hydrofluoric acid to implement nanotubes. Specifically, Ti6Al4V model implant samples were anodized first with sulfuric acid to create color-coding features, and then with hydrofluoric acid to implement surface features to enhance osteoblast functions. The material surfaces were characterized by visual inspection, scanning electron microscopy, contact angle measurements, and energy dispersive spectroscopy. Human osteoblasts were seeded onto the samples for a series of time points and were measured for adhesion and proliferation. After 1 and 2 weeks, the levels of alkaline phosphatase activity and calcium deposition were measured to assess the long-term differentiation of osteoblasts into the calcium depositing cells. The results showed that anodizing in hydrofluoric acid after anodizing in sulfuric acid partially retains color coding and creates unique surface features to increase osteoblast adhesion, proliferation, alkaline phosphatase activity, and calcium deposition. In this manner, this study provides a viable method to anodize an already color coded, anodized titanium alloy to potentially increase bone growth for numerous implant applications.
Jamzad, Amoon; Setarehdan, Seyed Kamaledin
2014-04-01
The twinkling artifact is an undesired phenomenon within color Doppler sonograms that usually appears at the site of internal calcifications. Since the appearance of the twinkling artifact is correlated with the roughness of the calculi, noninvasive roughness estimation of the internal stones may be considered as a potential twinkling artifact application. This article proposes a novel quantitative approach for measurement and analysis of twinkling artifact data for roughness estimation. A phantom was developed with 7 quantified levels of roughness. The Doppler system was initially calibrated by the proposed procedure to facilitate the analysis. A total of 1050 twinkling artifact images were acquired from the phantom, and 32 novel numerical measures were introduced and computed for each image. The measures were then ranked on the basis of roughness quantification ability using different methods. The performance of the proposed twinkling artifact-based surface roughness quantification method was finally investigated for different combinations of features and classifiers. Eleven features were shown to be the most efficient numerical twinkling artifact measures in roughness characterization. The linear classifier outperformed other methods for twinkling artifact classification. The pixel count measures produced better results among the other categories. The sequential selection method showed higher accuracy than other individual rankings. The best roughness recognition average accuracy of 98.33% was obtained by the first 5 principle components and the linear classifier. The proposed twinkling artifact analysis method could recognize the phantom surface roughness with average accuracy of 98.33%. This method may also be applicable for noninvasive calculi characterization in treatment management.
The effect of ambient lighting on Laser Doppler Imaging of a standardized cutaneous injury model
Pham, Alan Chuong Q; Hei, Erik La; Harvey, John G; Holland, Andrew JA
2017-01-01
Objective: The aim of this study was to investigate the potential confounding effects of four different types of ambient lighting on the results of Laser Doppler Imaging (LDI) of a standardized cutaneous injury model. Methods: After applying a mechanical stimulus to the anterior forearm of a healthy volunteer and inducing a wheal and arteriolar flare (the Triple response), we used a Laser Doppler Line Scanner (LDLS) to image the forearm under four different types of ambient lighting: light-emitting-diode (LED), compact fluorescent lighting (CFL), halogen, daylight, and darkness as a control. A spectrometer was used to measure the intensity of light energy at 785 nm, the wavelength used by the scanner for measurement under each type of ambient lighting. Results: Neither the LED nor CFL bulbs emitted detectable light energy at a wavelength of 785 nm. The color-based representation of arbitrary perfusion unit (APU) values of the Triple response measured by the scanner was similar between darkness, LED, and CFL light. Daylight emitted 2 mW at 785 nm, with a slight variation tending more towards lower APU values compared to darkness. Halogen lighting emitted 6 mW of light energy at 785 nm rendering the color-based representation impossible to interpret. Conclusions: Halogen lighting and daylight have the potential to confound results of LDI of cutaneous injuries whereas LED and CFL lighting did not. Any potential sources of daylight should be reduced and halogen lighting completely covered or turned off prior to wound imaging. PMID:29348978
[Intraoperative ultrasonography during laparoscopic surgery].
Alecu, L; Lungu, C; Pascu, A; Costan, I; Corodeanu, G; Deacu, A; Marin, A
2000-01-01
Of this study is the introduction and the results evaluation of laparoscopic ultrasonography performed. We realize a prospective study about laparoscopic ultrasonography performed in 37 cases with laparoscopic surgical treatment. The Aloka SSD 2000 mobile scanner is used. This system make possible the use of an linear-array transducer, with mechanical flexibility and availability of Doppler analysis. Most frequently we used intraoperative ultrasonography in laparoscopic cholecystectomy as an alternative for cholangiography to exclude CBD pathology. Because of various surgical pathology with laparoscopic approach, the laparoscopic ultrasonography utilization range was vastly. In all the cases we could performed the laparoscopic ultrasonography. In 6 of 27 cases with laparoscopic cholecystectomy we found pathological disorders of bile ducts. CBD with diameter found between 5-12 mm. We properly saw the distal segment of CBD in 23 cases (89.2%), and common hepatic duct in 26 cases (97.3%). The quality of visualization was very good in 21 cases (83.8%) and moderate in 6 cases (16.2%). We easy identify CBD stones and we successfully used Doppler color mode in differentiating vascular from non-vascular from non-vascular structures. Laparoscopic ultrasonography performed in a case with left colon cancer excluded liver metastasis and lymph nodes metastasis. 1. Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography; 2. Laparoscopic ultrasonography is a simple and very efficient intraoperative examination procedure; 3. Laparoscopic ultrasonography is the technique to choose in CBD intraoperative exploration; 4. Laparoscopic ultrasonography improve abdominal malignancy exploration, thus modifying therapeutic decisions; 5. Color Doppler mode guides the surgeon's steps in difficult directions.
Unraveling the Complexity of the Evolution of the Sun's Photospheric Magnetic Field
NASA Astrophysics Data System (ADS)
Hathaway, David H.
2016-10-01
Given the emergence of tilted, bipolar active regions, surface flux transport has been shown to reproduce much of the complex evolution of the Sun's photospheric magnetic field. Surface flux is transported by flows in the surface shear layer - the axisymmetric differential rotation and meridional flow and the non-axisymmetric convective motions (granules, supergranules, and giant cells). We have measured these flows by correlation tracking of the magnetic elements themselves, correlation tracking of the Doppler features (supergranules), and by direct Doppler measurements using SDO/HMI data. These measurements fully constrain (with no free parameters) the flows used in our surface flux transport code - the Advective Flux Transport or AFT code. Here we show the up-to-date evolution of these flows, their impact on the detailed evolution of the Sun's photospheric magnetic field, and predictions for what the polar fields will be at the next minimum in 2020.
Reif, Roberto; Zhi, Zhongwei; Dziennis, Suzan; Nuttall, Alfred L; Wang, Ruikang K
2013-10-01
In this work we determined the contributions of loud sound exposure (LSE) on cochlear blood flow (CoBF) in an in vivo anesthetized mouse model. A broadband noise system (20 kHz bandwidth) with an intensity of 119 dB SPL, was used for a period of one hour to produce a loud sound stimulus. Two techniques were used to study the changes in blood flow, a Doppler optical microangiography (DOMAG) system; which can measure the blood flow within individual cochlear vessels, and a laser Doppler flowmetry (LDF) system; which averages the blood flow within a volume (a hemisphere of ~1.5 mm radius) of tissue. Both systems determined that the blood flow within the cochlea is reduced due to the LSE stimulation.
Simon, Julianna C; Sapozhnikov, Oleg A; Kreider, Wayne; Breshock, Michael; Williams, James C; Bailey, Michael R
2018-01-09
The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.
NASA Astrophysics Data System (ADS)
Simon, Julianna C.; Sapozhnikov, Oleg A.; Kreider, Wayne; Breshock, Michael; Williams, James C., Jr.; Bailey, Michael R.
2018-01-01
The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.
Doppler-derived myocardial systolic strain rate is a strong index of left ventricular contractility
NASA Technical Reports Server (NTRS)
Greenberg, Neil L.; Firstenberg, Michael S.; Castro, Peter L.; Main, Michael; Travaglini, Agnese; Odabashian, Jill A.; Drinko, Jeanne K.; Rodriguez, L. Leonardo; Thomas, James D.; Garcia, Mario J.
2002-01-01
BACKGROUND: Myocardial fiber strain is directly related to left ventricular (LV) contractility. Strain rate can be estimated as the spatial derivative of velocities (dV/ds) obtained by tissue Doppler echocardiography (TDE). The purposes of the study were (1) to determine whether TDE-derived strain rate may be used as a noninvasive, quantitative index of contractility and (2) to compare the relative accuracy of systolic strain rate against TDE velocities alone. METHODS AND RESULTS: TDE color M-mode images of the interventricular septum were recorded from the apical 4-chamber view in 7 closed-chest anesthetized mongrel dogs during 5 different inotropic stages. Simultaneous LV volume and pressure were obtained with a combined conductance-high-fidelity pressure catheter. Peak elastance (Emax) was determined as the slope of end-systolic pressure-volume relationships during caval occlusion and was used as the gold standard of LV contractility. Peak systolic TDE myocardial velocities (Sm) and peak (epsilon'(p)) and mean (epsilon'(m)) strain rates obtained at the basal septum were compared against Emax by linear regression. Emax as well as TDE systolic indices increased during inotropic stimulation with dobutamine and decreased with the infusion of esmolol. A stronger association was found between Emax and epsilon'(p) (r=0.94, P<0.01, y=0.29x+0.46) and epsilon'(m) (r=0.88, P<0.01) than for Sm (r=0.75, P<0.01). CONCLUSIONS: TDE-derived epsilon'(p) and epsilon'(m) are strong noninvasive indices of LV contractility. These indices appear to be more reliable than S(m), perhaps by eliminating translational artifact.
Perceptions of drug color among drug sellers and consumers in rural southwestern Nigeria.
Brieger, William R; Salami, Kabiru K; Oshiname, Frederick O
2007-09-01
Color is commonly used for branding and coding consumer products including medications. People associate certain colors in tablets and capsules with the effect of the drug and the illness for which it is meant. Color coding was introduced in age-specific prepacked antimalarial drugs for preschool aged children in Nigeria by the National Malaria Control Committee. Yellow was designated for the younger ages and blue for the older. The National Malaria Control Committee did not perform market research to learn how their color codes would be perceived by consumers. The study aimed at determining perceptions of both consumers and sellers of medicines at the community level to learn about color likes and dislikes that might influence acceptance of new color-coded child prepacks of antimalarial drugs. Qualitative methods were used to determine perceptions of drug colors. A series of focus group interviews were conducted with male and female community members, and in-depth interviews were held with medicine sellers in the Igbo-Ora community in southwestern Nigeria. Respondents clearly associated medicines with their effects and purpose, for example white drugs for pain relief, red for building blood, blue to aid sleep, and yellow for malaria treatment. Medicine vendors had a low opinion of white colored medicines, but community members were ultimately more concerned about efficacy. The perceived association between yellow and malaria, because of local symptom perceptions of eyes turning yellowish during malaria, yielded a favorable response when consumers were shown the yellow prepacks. The response to blue was noncommittal but consumers indicated that if they were properly educated on the efficacy and function of the new drugs they would likely buy them. Community members will accept yellow as an antimalarial drug but health education will be needed for promoting the idea of blue for malaria and the notion of age-specific packets. Therefore, the strong medicine vendor-training component that accompanied roll out of these prepacks in the pilot states needs to be replicated nationally.
Visualization and Analysis of Microtubule Dynamics Using Dual Color-Coded Display of Plus-End Labels
Garrison, Amy K.; Xia, Caihong; Wang, Zheng; Ma, Le
2012-01-01
Investigating spatial and temporal control of microtubule dynamics in live cells is critical to understanding cell morphogenesis in development and disease. Tracking fluorescently labeled plus-end-tracking proteins over time has become a widely used method to study microtubule assembly. Here, we report a complementary approach that uses only two images of these labels to visualize and analyze microtubule dynamics at any given time. Using a simple color-coding scheme, labeled plus-ends from two sequential images are pseudocolored with different colors and then merged to display color-coded ends. Based on object recognition algorithms, these colored ends can be identified and segregated into dynamic groups corresponding to four events, including growth, rescue, catastrophe, and pause. Further analysis yields not only their spatial distribution throughout the cell but also provides measurements such as growth rate and direction for each labeled end. We have validated the method by comparing our results with ground-truth data derived from manual analysis as well as with data obtained using the tracking method. In addition, we have confirmed color-coded representation of different dynamic events by analyzing their history and fate. Finally, we have demonstrated the use of the method to investigate microtubule assembly in cells and provided guidance in selecting optimal image acquisition conditions. Thus, this simple computer vision method offers a unique and quantitative approach to study spatial regulation of microtubule dynamics in cells. PMID:23226282
Realistic tissue visualization using photoacoustic image
NASA Astrophysics Data System (ADS)
Cho, Seonghee; Managuli, Ravi; Jeon, Seungwan; Kim, Jeesu; Kim, Chulhong
2018-02-01
Visualization methods are very important in biomedical imaging. As a technology that understands life, biomedical imaging has the unique advantage of providing the most intuitive information in the image. This advantage of biomedical imaging can be greatly improved by choosing a special visualization method. This is more complicated in volumetric data. Volume data has the advantage of containing 3D spatial information. Unfortunately, the data itself cannot directly represent the potential value. Because images are always displayed in 2D space, visualization is the key and creates the real value of volume data. However, image processing of 3D data requires complicated algorithms for visualization and high computational burden. Therefore, specialized algorithms and computing optimization are important issues in volume data. Photoacoustic-imaging is a unique imaging modality that can visualize the optical properties of deep tissue. Because the color of the organism is mainly determined by its light absorbing component, photoacoustic data can provide color information of tissue, which is closer to real tissue color. In this research, we developed realistic tissue visualization using acoustic-resolution photoacoustic volume data. To achieve realistic visualization, we designed specialized color transfer function, which depends on the depth of the tissue from the skin. We used direct ray casting method and processed color during computing shader parameter. In the rendering results, we succeeded in obtaining similar texture results from photoacoustic data. The surface reflected rays were visualized in white, and the reflected color from the deep tissue was visualized red like skin tissue. We also implemented the CUDA algorithm in an OpenGL environment for real-time interactive imaging.
Attique, Muhammad; Gilanie, Ghulam; Hafeez-Ullah; Mehmood, Malik S.; Naweed, Muhammad S.; Ikram, Masroor; Kamran, Javed A.; Vitkin, Alex
2012-01-01
Characterization of tissues like brain by using magnetic resonance (MR) images and colorization of the gray scale image has been reported in the literature, along with the advantages and drawbacks. Here, we present two independent methods; (i) a novel colorization method to underscore the variability in brain MR images, indicative of the underlying physical density of bio tissue, (ii) a segmentation method (both hard and soft segmentation) to characterize gray brain MR images. The segmented images are then transformed into color using the above-mentioned colorization method, yielding promising results for manual tracing. Our color transformation incorporates the voxel classification by matching the luminance of voxels of the source MR image and provided color image by measuring the distance between them. The segmentation method is based on single-phase clustering for 2D and 3D image segmentation with a new auto centroid selection method, which divides the image into three distinct regions (gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) using prior anatomical knowledge). Results have been successfully validated on human T2-weighted (T2) brain MR images. The proposed method can be potentially applied to gray-scale images from other imaging modalities, in bringing out additional diagnostic tissue information contained in the colorized image processing approach as described. PMID:22479421
ERIC Educational Resources Information Center
Yildiz, Necmettin; Gokkaya, Nilufer Kutay Ordu; Koseoglu, Fusun; Gokkaya, Serkan; Comert, Didem
2011-01-01
The aim of the study was to determine which vasoactive agent was more efficacious for erectile dysfunction (ED), intracavernosal papaverine or oral sildenafil, in paraplegic men within the first year after injury by using a penile color Doppler ultrasound as a quantitative imaging method and to determine the association between responses to these…
Biagiotti, R; Desii, C; Vanzi, E; Gacci, G
1999-02-01
To compare the performance of artificial neural networks (ANNs) with that of multiple logistic regression (MLR) models for predicting ovarian malignancy in patients with adnexal masses by using transvaginal B-mode and color Doppler flow ultrasonography (US). A total of 226 adnexal masses were examined before surgery: Fifty-one were malignant and 175 were benign. The data were divided into training and testing subsets by using a "leave n out method." The training subsets were used to compute the optimum MLR equations and to train the ANNs. The cross-validation subsets were used to estimate the performance of each of the two models in predicting ovarian malignancy. At testing, three-layer back-propagation networks, based on the same input variables selected by using MLR (i.e., women's ages, papillary projections, random echogenicity, peak systolic velocity, and resistance index), had a significantly higher sensitivity than did MLR (96% vs 84%; McNemar test, p = .04). The Brier scores for ANNs were significantly lower than those calculated for MLR (Student t test for paired samples, P = .004). ANNs might have potential for categorizing adnexal masses as either malignant or benign on the basis of multiple variables related to demographic and US features.
Acute appendicitis-like symptoms as initial presentation of ovarian vein thrombosis.
Prieto-Nieto, M I; Perez-Robledo, J P; Rodriguez-Montes, J A; Garci-Sancho-Martin, L
2004-07-01
Postpartum ovarian vein thrombosis is a rare condition, with an incidence rate being 1/600 deliveries. It most often arises in the right ovarian vein. A 33-year-old patient who had had normal vaginal delivery presented with fever, pain in the right iliac fossa, and leukocytosis on the sixth day after delivery. An antibiotic course was instituted but 3 days later symptoms reappeared. Diagnosis of acute appendicitis was made. At surgery through a McBurney incision, a woody tumoration consistent with ovarian vein thrombosis was found. Anticoagulation therapy with heparin and antibiotics were instituted. Phlebography and color Doppler sonography confirmed the presence of thrombosis of both the common femoral iliac and inferior vena cava. Fribrolysis with urokinase was performed. The patient has remained stable and symptom-free over a 4-year follow-up. Ovarian vein thrombosis typically presents with symptoms suggestive of acute appendicitis, as was the case in our patient. Color Doppler sonography is the favored diagnostic procedure, with CT being a supplementary tool. Surgery is not necessary and treatment consists of anticoagulants and antibiotics. Even though postpartum ovarian vein thrombosis is rare, early recognition of the condition is of paramount importance to institute the adequate treatment and avoid potential serious sequelae.
Liu, Li-Ping; Dong, Bao-Wei; Yu, Xiao-Ling; Zhang, Da-Kun; Li, Xin; Li, Hua
2008-03-01
The purpose of this study was to investigate whether focal fatty sparing (FFS) formation in the liver relates to aberrant blood flow. Sixty-three FFSs of the liver in 52 patients were examined by color Doppler flow imaging and contrast-enhanced microvessel display sonography. The 63 FFSs included 16 FFSs in the porta hepatis, 14 FFSs around the gallbladder fossa, and 33 other FFSs. The control group included patients with a diagnosis of fatty liver but no FFSs or focal lesions near the porta hepatis. Fourteen of 16 FFSs in the porta hepatis showed venous blood toward those areas that were differentiated from the portal and hepatic veins. Focal fatty sparings in the hilus hepatis correlated with aberrant veins, having a statistical significance compared with the control group (P < .0001). Seven of 14 FFSs around the gallbladder fossa contained blood vessels, 5 of them veins and the remaining 2 arteries. Two FFSs were located around hemangiomas. Three FFSs were located around maldeveloped vessels. The blood supply to an FFS in the porta hepatis may be correlated with aberrant veins. Focal fatty sparings around the gallbladder fossa may be associated with aberrant blood flow.
NASA Astrophysics Data System (ADS)
Dadkhah, Arash; Zhou, Jun; Yeasmin, Nusrat; Jiao, Shuliang
2018-02-01
Various optical imaging modalities with different optical contrast mechanisms have been developed over the past years. Although most of these imaging techniques are being used in many biomedical applications and researches, integration of these techniques will allow researchers to reach the full potential of these technologies. Nevertheless, combining different imaging techniques is always challenging due to the difference in optical and hardware requirements for different imaging systems. Here, we developed a multimodal optical imaging system with the capability of providing comprehensive structural, functional and molecular information of living tissue in micrometer scale. This imaging system integrates photoacoustic microscopy (PAM), optical coherence tomography (OCT), optical Doppler tomography (ODT) and fluorescence microscopy in one platform. Optical-resolution PAM (OR-PAM) provides absorption-based imaging of biological tissues. Spectral domain OCT is able to provide structural information based on the scattering property of biological sample with no need for exogenous contrast agents. In addition, ODT is a functional extension of OCT with the capability of measurement and visualization of blood flow based on the Doppler effect. Fluorescence microscopy allows to reveal molecular information of biological tissue using autofluoresce or exogenous fluorophores. In-vivo as well as ex-vivo imaging studies demonstrated the capability of our multimodal imaging system to provide comprehensive microscopic information on biological tissues. Integrating all the aforementioned imaging modalities for simultaneous multimodal imaging has promising potential for preclinical research and clinical practice in the near future.
Poh, Kian-Keong; Chan, Mark Yan-Yee; Yang, Hong; Yong, Quek-Wei; Chan, Yiong-Huak; Ling, Lieng H
2008-05-01
Intact left atrial booster pump function helps maintain cardiac compensation in patients with aortic valve stenosis (AS). Because late diastolic mitral annular (A') velocity reflects left atrial systolic function, we hypothesized that A' velocity correlates with plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) level and clinical outcome in AS. We prospectively enrolled 53 consecutive patients (median age 74 years) with variable degrees of AS, in sinus rhythm, and left ventricular ejection fraction greater than 50%. Indices of valvular stenosis, left ventricular diastolic dysfunction, and mitral annular motion were correlated with plasma NT-proBNP and a composite clinical end point comprising cardiac death and symptom-driven aortic valve replacement. Tissue Doppler echocardiographic parameters, including early diastolic (E') velocity and A' velocity and ratio of early diastolic transmitral (E) to E' velocity (E/E') at the annular septum correlated better with NT-proBNP levels than body surface area-indexed aortic valve area. Eighteen patients had the composite end point, which was univariately predicted by body surface area-indexed aortic valve area, NT-proBNP, and all tissue Doppler echocardiographic indices. This outcome was most strongly predicted by the combination of septal A' velocity and E/E' ratio in bivariate Cox modeling. Septal annular A' velocity less than 9.6 cm/s was associated with significantly reduced event-free survival (Kaplan Meier log rank = 27.3, P < .0001) and predicted the end point with a sensitivity, specificity, and accuracy of 94%, 80%, and 85%, respectively. In patients with AS and normal ejection fraction, annular tissue Doppler echocardiographic indices may better reflect the physiologic consequences of afterload burden on the left ventricle than body surface area-indexed aortic valve area. Lower A' velocity is a predictor of cardiac death and need for valve surgery, suggesting an important role for compensatory left atrial booster pump function.
Signature management of radar returns from wind turbine generators
NASA Astrophysics Data System (ADS)
Tennant, A.; Chambers, B.
2006-04-01
The large radar cross section of wind turbine generator (WTG) blades combined with high tip speeds can produce significant Doppler returns when illuminated by a radar. Normally, an air traffic control radar system will filter out large returns from stationary targets, but the Doppler shifts introduced by the WTG blades are interpreted as moving aircraft that can confuse radar operators and compromise safety. A possible solution to this problem is to incorporate an active layer into the structure of the WTG blades that can be used to dynamically modulate the radar cross section (RCS) of the blade return. The active blade can operate in one of two modes: first the blade RCS can be modulated to provide a Doppler return that is outside the detectable range of the radar receiver system so that it is rejected; a second mode of operation is to introduce specific coding onto the Doppler returns so that they may be uniquely identified and rejected. The active layer used in the system consists of a frequency selective surface controlled by semiconductor diodes and is a development of techniques developed for active radar absorbers. Results of theoretical and experimental work using a 10 GHz Doppler radar and scale-model WTG are presented.
7 CFR 28.525 - Symbols and code numbers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...
7 CFR 28.525 - Symbols and code numbers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...
7 CFR 28.525 - Symbols and code numbers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...
7 CFR 28.525 - Symbols and code numbers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...
7 CFR 28.525 - Symbols and code numbers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... designations in inches. (a) Symbols and Code numbers used for Color Grades of American Upland Cotton. Color... 41 Low Middling LM 51 Strict Good Ordinary SGO 61 Good Ordinary GO 71 Good Middling Light Spotted GM Lt SP 12 Strict Middling Light Spotted SM Lt Sp 22 Middling Light Spotted Mid Lt Sp 32 Strict Low...
ERIC Educational Resources Information Center
Clinton, Virginia; Morsanyi, Kinga; Alibali, Martha W.; Nathan, Mitchell J.
2016-01-01
Learning from visual representations is enhanced when learners appropriately integrate corresponding visual and verbal information. This study examined the effects of two methods of promoting integration, color coding and labeling, on learning about probabilistic reasoning from a table and text. Undergraduate students (N = 98) were randomly…
NASA Technical Reports Server (NTRS)
1992-01-01
The work performed in the previous six months can be divided into three main cases: (1) transmission of images over local area networks (LAN's); (2) coding of color mapped (pseudo-color) images; and (3) low rate video coding. A brief overview of the work done in the first two areas is presented. The third item is reported in somewhat more detail.
NASA Astrophysics Data System (ADS)
Chen, Shuo; Lin, Xiaoqian; Zhu, Caigang; Liu, Quan
2014-12-01
Key tissue parameters, e.g., total hemoglobin concentration and tissue oxygenation, are important biomarkers in clinical diagnosis for various diseases. Although point measurement techniques based on diffuse reflectance spectroscopy can accurately recover these tissue parameters, they are not suitable for the examination of a large tissue region due to slow data acquisition. The previous imaging studies have shown that hemoglobin concentration and oxygenation can be estimated from color measurements with the assumption of known scattering properties, which is impractical in clinical applications. To overcome this limitation and speed-up image processing, we propose a method of sequential weighted Wiener estimation (WE) to quickly extract key tissue parameters, including total hemoglobin concentration (CtHb), hemoglobin oxygenation (StO2), scatterer density (α), and scattering power (β), from wide-band color measurements. This method takes advantage of the fact that each parameter is sensitive to the color measurements in a different way and attempts to maximize the contribution of those color measurements likely to generate correct results in WE. The method was evaluated on skin phantoms with varying CtHb, StO2, and scattering properties. The results demonstrate excellent agreement between the estimated tissue parameters and the corresponding reference values. Compared with traditional WE, the sequential weighted WE shows significant improvement in the estimation accuracy. This method could be used to monitor tissue parameters in an imaging setup in real time.
1998 NASA Review: Center for Space Telemetering and Telecommunication Systems
NASA Technical Reports Server (NTRS)
Cunningham, Garry
1998-01-01
The following topics are included in the conference proceedings following the program overview: (1) Coding and Carrier Recovery Techniques; (2) Carrier Frequency Estimation Under Unknown Doppler Shifts; (3) Small Satellite Experiments; (4) Bandwidth Efficient Modulation/Equalization Techniques.
SU-E-J-31: Biodynamic Imaging of Cancer Tissue and Response to Chemotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nolte, D; Turek, J; Childress, M
2014-06-01
Purpose: To measure intracellular motions inside three-dimensional living cancer tissue samples to establish a novel set of biodynamic biomarkers that assess tissue proliferative activity and sensitivity or resistance to chemotherapy. Methods: Biodynamic imaging (BDI) uses digital holography with low-coherence low-intensity light illumination to construct 3D holograms from depths up to a millimeter deep inside cancer tissue models that include multicellular tumor spheroids and ex vivo cancer biopsies from canine non-Hodgkins lymphoma and epithelial ovarian cancer (EOC) mouse explants. Intracellular motions modulate the holographic intensity with frequencies related to the Doppler effect caused by the motions of a wide variety ofmore » intracellular components. These motions are affected by applied therapeutic agents, and BDI produces unique fingerprints of the action of specific drugs on the motions in specific cell types. In this study, chemotherapeutic agents (doxorubicin for canine lymphoma and oxoplatin for ovarian) are applied to the living tissue models and monitored over 10 hours by BDI. Results: Multicellular spheroids and patient biopsies are categorized as either sensitive or insensitive to applied therapeutics depending on the intracellular Doppler signatures of chemotherapy response. For both lymphoma and EOC there is strong specificity to the two types of sensitivities, with sensitive cell lines and biopsies exhibiting a global cessation of proliferation and strong suppression of metabolic activity, while insensitive cell lines and biopsies show moderate activation of Doppler frequencies associated with membrane processes and possible membrane trafficking. Conclusion: This work supports the hypothesis that biodynamic biomarkers from three-dimensional living tumor tissue, that includes tissue heterogeneity and measured within 24 hours of surgery, is predictive of near-term patient response to therapy. Future work will correlate biodynamic biomarkers with progression free survival times. This work is supported by NIH 1R01EB016582 and NSF 1263753-CBET. Nolte, Turek and An have a financial interest in Animated Dynamics, Inc. that will be licensing technology from Purdue University.« less
Detection of virus in shrimp using digital color correlation
NASA Astrophysics Data System (ADS)
Alvarez-Borrego, Josue; Chavez-Sanchez, Cristina; Bueno-Ibarra, Mario A.
1999-07-01
Detection of virus in shrimp tissue using digital color correlation is presented. Phase filters in three channels (red, green and blue) were used in order to detect HPV virus like target. These first results obtained showed that is possible to detect virus in shrimp tissue. More research must be made with color correlation in order to consider natural morphology of the virus, color, scale and rotation and noise in the samples.
Mertens, H W; Milburn, N J; Collins, W E
2000-12-01
Two practical color vision tests were developed and validated for use in screening Air Traffic Control Specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulation of color-coded materials from the most demanding, safety-critical color task performed in each type of facility. The tests were evaluated using 106 subjects with normal color vision and 85 with color vision deficiency. The en route center test, named the Flight Progress Strips Test (FPST), required the identification of critical red/black coding in computer printing and handwriting on flight progress strips. The terminal option test, named the Aviation Lights Test (ALT), simulated red/green/white aircraft lights that must be identified in night ATC tower operations. Color-coding is a non-redundant source of safety-critical information in both tasks. The FPST was validated by direct comparison of responses to strip reproductions with responses to the original flight progress strips and a set of strips selected independently. Validity was high; Kappa = 0.91 with original strips as the validation criterion and 0.86 with different strips. The light point stimuli of the ALT were validated physically with a spectroradiometer. The reliabilities of the FPST and ALT were estimated with Chronbach's alpha as 0.93 and 0.98, respectively. The high job-relevance, validity, and reliability of these tests increases the effectiveness and fairness of ATCS color vision testing.
Kaplanoglu, Mustafa; Karateke, Atilla; Un, Burak; Gunsoy, Levend; Baloglu, Ali
2015-01-01
Aim: The evaluation of the uterine artery recanalization rate and color Doppler parameters during follow-up after bilateral uterine artery ligation (BUAL) for postpartum hemorrhage (PPH) related to uterine atony. Material and method: A total of 40 female patients who underwent BUAL for PPH related to uterine atony and 96 females who gave birth without complication at Hatay Obstetrics and Gynecology Hospital between January 2009 and December 2012 (48 months) were included in the study. The patients’ uterine artery recanalization rate and all subjects’ color Doppler ultrasonographic parameters (PI, RI, PSV and EDV) were evaluated at the 6th and 12th months. Result: No statistically significant difference was found between the age, obstetric history (gravida and parity), BMI, type of delivery, birth weight and gestational age when the demographic data of the groups were evaluated. The patient group UtA recanalization rate was 32.5% and 37.5% for the left and right UtA respectively at the 12-month follow-up. No statistically significant difference was found in the comparison of 6- and 12-month right and left uterine artery diameters and color doppler parameters of the patient group (UtA diameters P=0.322 and P=0.787, RI index P=0.390 and P=0.094, PI index P=0.949 and P=0.374, PSV P=0.335 and P=0.085, EDV P=0.173 and P=0.418, respectively). However, right and left ovarian volume was found to significantly increase during follow-up in patient group (P<0.001 for both right and left ovary). On the other hand, a statistically significant difference was found between the patient group and the control group in the comparison of the 6- and 12-month right and left uterine artery values (6th month; P<0.001 for both UtA diameters, RI, PI, PSV, EDV; 12th month; P<0.001 for right UtA diameter, RI, PI, PSV, EDV and P=0.002 for left UtA diameter). A statistically significant difference was found only in right ovary volume in the 6th month evaluation of the patient and control group ovary volumes (P=0.011). Discussion: The recanalization rate and isolated uterine blood supply during low-term follow-up are low following the BUAL technique. The evaluation of future fertility results will be helpful in determining the reliability of this procedure in a definite manner. PMID:26221335
Mor-Avi, Victor; Lang, Roberto M; Badano, Luigi P; Belohlavek, Marek; Cardim, Nuno Miguel; Derumeaux, Genevieve; Galderisi, Maurizio; Marwick, Thomas; Nagueh, Sherif F; Sengupta, Partho P; Sicari, Rosa; Smiseth, Otto A; Smulevitz, Beverly; Takeuchi, Masaaki; Thomas, James D; Vannan, Mani; Voigt, Jens-Uwe; Zamorano, Jose Luis
2011-03-01
Echocardiographic imaging is ideally suited for the evaluation of cardiac mechanics because of its intrinsically dynamic nature. Because for decades, echocardiography has been the only imaging modality that allows dynamic imaging of the heart, it is only natural that new, increasingly automated techniques for sophisticated analysis of cardiac mechanics have been driven by researchers and manufacturers of ultrasound imaging equipment. Several such techniques have emerged over the past decades to address the issue of reader's experience and inter-measurement variability in interpretation. Some were widely embraced by echocardiographers around the world and became part of the clinical routine, whereas others remained limited to research and exploration of new clinical applications. Two such techniques have dominated the research arena of echocardiography: (1) Doppler-based tissue velocity measurements, frequently referred to as tissue Doppler or myocardial Doppler, and (2) speckle tracking on the basis of displacement measurements. Both types of measurements lend themselves to the derivation of multiple parameters of myocardial function. The goal of this document is to focus on the currently available techniques that allow quantitative assessment of myocardial function via image-based analysis of local myocardial dynamics, including Doppler tissue imaging and speckle-tracking echocardiography, as well as integrated back- scatter analysis. This document describes the current and potential clinical applications of these techniques and their strengths and weaknesses, briefly surveys a selection of the relevant published literature while highlighting normal and abnormal findings in the context of different cardiovascular pathologies, and summarizes the unresolved issues, future research priorities, and recommended indications for clinical use.
Mor-Avi, Victor; Lang, Roberto M; Badano, Luigi P; Belohlavek, Marek; Cardim, Nuno Miguel; Derumeaux, Geneviève; Galderisi, Maurizio; Marwick, Thomas; Nagueh, Sherif F; Sengupta, Partho P; Sicari, Rosa; Smiseth, Otto A; Smulevitz, Beverly; Takeuchi, Masaaki; Thomas, James D; Vannan, Mani; Voigt, Jens-Uwe; Zamorano, José Luis
2011-03-01
Echocardiographic imaging is ideally suited for the evaluation of cardiac mechanics because of its intrinsically dynamic nature. Because for decades, echocardiography has been the only imaging modality that allows dynamic imaging of the heart, it is only natural that new, increasingly automated techniques for sophisticated analysis of cardiac mechanics have been driven by researchers and manufacturers of ultrasound imaging equipment.Several such technique shave emerged over the past decades to address the issue of reader's experience and inter measurement variability in interpretation.Some were widely embraced by echocardiographers around the world and became part of the clinical routine,whereas others remained limited to research and exploration of new clinical applications.Two such techniques have dominated the research arena of echocardiography: (1) Doppler based tissue velocity measurements,frequently referred to as tissue Doppler or myocardial Doppler, and (2) speckle tracking on the basis of displacement measurements.Both types of measurements lend themselves to the derivation of multiple parameters of myocardial function. The goal of this document is to focus on the currently available techniques that allow quantitative assessment of myocardial function via image-based analysis of local myocardial dynamics, including Doppler tissue imaging and speckle-tracking echocardiography, as well as integrated backscatter analysis. This document describes the current and potential clinical applications of these techniques and their strengths and weaknesses,briefly surveys a selection of the relevant published literature while highlighting normal and abnormal findings in the context of different cardiovascular pathologies, and summarizes the unresolved issues, future research priorities, and recommended indications for clinical use.
Documentation for the Computer Assisted Diagnostic Program for Dental Pain
1989-04-10
Questioni 1, if "No" (2), then go to Questioni 20. 6. Aside from possible racial pigmentation , if present, what is the color of the gingival tissues... pigmentation , if present, what is the color of the gingival tissues (gum)? 1. Pink 2. Red 3. Pink with red gingival margins 4. Either #2 or #3 above, but...racial pigmentation , if present, what is the color of the gingival tissues (gum)? 1. Pink 2. Red 3. Pink with red gingival margins 4. Either #2 or #3
Stevens, Allen D.; Hernandez, Caleb; Jones, Seth; Moreira, Maria E.; Blumen, Jason R.; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S.
2016-01-01
Background Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. Methods We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded-syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Results Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28–39) seconds and 42 (95% CI: 36–51) seconds, respectively (difference = 9 [95% CI: 4–14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference = 39%, 95% CI: 13–61%). Conclusions A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. PMID:26247145
Stevens, Allen D; Hernandez, Caleb; Jones, Seth; Moreira, Maria E; Blumen, Jason R; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S
2015-11-01
Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28-39) seconds and 42 (95% CI: 36-51) seconds, respectively (difference=9 [95% CI: 4-14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference=39%, 95% CI: 13-61%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja)
de Moraes, Wanderlei; Ferreira, Thiago A.C.; Somma, André T.; Cubas, Zalmir S.; Moore, Bret A.; Montiani-Ferreira, Fabiano
2017-01-01
Twenty harpy eagles (Harpia harpyja) without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI) and pulsatility index (PI) were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation. PMID:28540254
In Vivo Determination of the Complex Elastic Moduli of Cetacean Head Tissue
2012-09-30
and with harvested tissue samples. In vivo testing will be conducted on Navy dolphins . Ultrasound parameters (peak negative pressure, time averaged...A synthetic material was developed which mimicks the ultrasonic properties of living bottlenose dolphin soft tissues. RESULTS 1. System...NIVMS) and with a laser doppler vibrometer (Polytec PDV-100). A variety of pulse drive levels, durations, and bandwidths for both ultrasound
Color Code: Using Hair Color to Make a Clear Connection between Genotype and Phenotype
ERIC Educational Resources Information Center
Bonner, J. Jose
2011-01-01
Students may wonder why they look the way they do. The answer lies in genetics, the branch of biology that deals with heredity and the variation of inherited traits. However, understanding how an organism's genetic code (i.e., genotype) affects its characteristics (i.e., phenotype) is more than a matter of idle curiosity: It's essential for…
Effect of task demands on dual coding of pictorial stimuli.
Babbitt, B C
1982-01-01
Recent studies have suggested that verbal labeling of a picture does not occur automatically. Although several experiments using paired-associate tasks produced little evidence indicating the use of a verbal code with picture stimuli, the tasks were probably not sensitive to whether the codes were activated initially. It is possible that verbal labels were activated at input, but not used later in performing the tasks. The present experiment used a color-naming interference task in order to assess, with a more sensitive measure, the amount of verbal coding occurring in response to word or picture input. Subjects named the color of ink in which words were printed following either word or picture input. If verbal labeling of the input occurs, then latency of color naming should increase when the input item and color-naming word are related. The results provided substantial evidence of such verbal activation when the input items were words. However, the presence of verbal activation with picture input was a function of task demands. Activation occurred when a recall memory test was used, but not when a recognition memory test was used. The results support the conclusion that name information (labels) need not be activated during presentation of visual stimuli.
Modeling and processing of laser Doppler reactive hyperaemia signals
NASA Astrophysics Data System (ADS)
Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre
2003-07-01
Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.
Color Analysis of Periimplant Soft Tissues Focusing on Implant System: A Case Series.
Varoni, Elena M; Moltrasio, Giuseppe; Gargano, Marco; Ludwig, Nicola; Lodi, Giovanni; Scaringi, Riccardo
2017-04-01
To assess the impact of implant system on color harmonization of periimplant mucosa. In this case series, color of periimplant mucosa was compared with color of natural tooth gingiva. Seventeen intercanine implants were analyzed (11 bone level [BL], 6 tissue level [TL] implants). Colorimetric data, at 2, 4, and 6 mm from gingival margin, were collected through fiber optics reflectance spectroscopy, and color differences calculated as ΔE. Dentists, dental students, and lay people, in blind, performed an additional visual color analysis on clinical images. Independently from implant system, the color of periimplant mucosa was significantly different from gingiva (ΔE = 8.2 ± 0.7), resulting darker at L* comparison (P ≤ 0.05). TL periimplant mucosa showed higher ΔE than BL (9.0 ± 1.0 vs 6.6 ± 0.8, respectively; P ≤ 0.05). Observers correctly identified where the implant was placed in about half of the cases, with no significant difference between implant systems. Within the limitations of this study, the color of periimplant soft tissues appears different from gingiva, at spectroscopic analysis. Color discrepancy results higher in the presence of TL implants than in BL implants, although the difference may not be clinically significant.
Martins, W P; Raine-Fenning, N J; Ferriani, R A; Nastri, C O
2010-03-01
To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in 'flow-free' models. 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PRF) settings. Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. (c) 2010 ISUOG. Published by John Wiley & Sons, Ltd.