Leng, Pei-Qiang; Zhao, Feng-Lan; Yin, Bin-Cheng; Ye, Bang-Ce
2015-05-21
We developed a novel colorimetric method for rapid detection of biogenic amines based on arylalkylamine N-acetyltransferase (aaNAT). The proposed method offers distinct advantages including simple handling, high speed, low cost, good sensitivity and selectivity.
ERIC Educational Resources Information Center
Koesdjojo, Myra T.; Pengpumkiat, Sumate; Wu, Yuanyuan; Boonloed, Anukul; Huynh, Daniel; Remcho, Thomas P.; Remcho, Vincent T.
2015-01-01
We have developed a simple and direct method to fabricate paper-based microfluidic devices that can be used for a wide range of colorimetric assay applications. With these devices, assays can be performed within minutes to allow for quantitative colorimetric analysis by use of a widely accessible iPhone camera and an RGB color reader application…
Kangas, Michael J; Burks, Raychelle M; Atwater, Jordyn; Lukowicz, Rachel M; Garver, Billy; Holmes, Andrea E
2018-02-01
With the increasing availability of digital imaging devices, colorimetric sensor arrays are rapidly becoming a simple, yet effective tool for the identification and quantification of various analytes. Colorimetric arrays utilize colorimetric data from many colorimetric sensors, with the multidimensional nature of the resulting data necessitating the use of chemometric analysis. Herein, an 8 sensor colorimetric array was used to analyze select acid and basic samples (0.5 - 10 M) to determine which chemometric methods are best suited for classification quantification of analytes within clusters. PCA, HCA, and LDA were used to visualize the data set. All three methods showed well-separated clusters for each of the acid or base analytes and moderate separation between analyte concentrations, indicating that the sensor array can be used to identify and quantify samples. Furthermore, PCA could be used to determine which sensors showed the most effective analyte identification. LDA, KNN, and HQI were used for identification of analyte and concentration. HQI and KNN could be used to correctly identify the analytes in all cases, while LDA correctly identified 95 of 96 analytes correctly. Additional studies demonstrated that controlling for solvent and image effects was unnecessary for all chemometric methods utilized in this study.
Amirjani, Amirmostafa; Fatmehsari, Davoud Haghshenas
2018-01-01
In this work, a rapid and straightforward method was developed for colorimetric determination of ammonia using smartphones. The mechanisms is based on the manipulation of the surface plasmon band of silver nanoparticles (AgNPs) via the formation of Ag (NH 3 ) 2 + complex. This complex decreases the amount of AgNPs in the solution and consequently, the color intensity of the colloidal system decreases. Not only the variation in color intensity of the solution can be tracked by a UV-vis spectrophotometer, but also a smartphone can be employed to monitor the color intensity variation by RGB analysis. Ammonia, in the concentration range of 10-1000mgL -1 , was successfully measured spectrophotometrically (UV-vis spectrophotometer) and colorimetrically (RGB measurement) with the detection limit of 180 and 200mgL -1 , respectively. Linear relationships were also developed for both methods. Also, the response time of the developed colorimetric sensor was around 20s. Both of the colorimetric and spectrophotometric methods showed a reliable performance for determination of ammonia in the real samples. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Fang, Jingyu; Xu, Haisong; Wang, Zhehong; Wu, Xiaomin
2016-05-01
With colorimetric characterization, digital cameras can be used as image-based tristimulus colorimeters for color communication. In order to overcome the restriction of fixed capture settings adopted in the conventional colorimetric characterization procedures, a novel method was proposed considering capture settings. The method calculating colorimetric value of the measured image contains five main steps, including conversion from RGB values to equivalent ones of training settings through factors based on imaging system model so as to build the bridge between different settings, scaling factors involved in preparation steps for transformation mapping to avoid errors resulted from nonlinearity of polynomial mapping for different ranges of illumination levels. The experiment results indicate that the prediction error of the proposed method, which was measured by CIELAB color difference formula, reaches less than 2 CIELAB units under different illumination levels and different correlated color temperatures. This prediction accuracy for different capture settings remains the same level as the conventional method for particular lighting condition.
Gong, Rui; Xu, Haisong; Tong, Qingfen
2012-10-20
The colorimetric characterization of active matrix organic light emitting diode (AMOLED) panels suffers from their poor channel independence. Based on the colorimetric characteristics evaluation of channel independence and chromaticity constancy, an accurate colorimetric characterization method, namely, the polynomial compensation model (PC model) considering channel interactions was proposed for AMOLED panels. In this model, polynomial expressions are employed to calculate the relationship between the prediction errors of XYZ tristimulus values and the digital inputs to compensate the XYZ prediction errors of the conventional piecewise linear interpolation assuming the variable chromaticity coordinates (PLVC) model. The experimental results indicated that the proposed PC model outperformed other typical characterization models for the two tested AMOLED smart-phone displays and for the professional liquid crystal display monitor as well.
Tsukatani, Tadayuki; Suenaga, Hikaru; Ishiyama, Munetaka; Ezoe, Takatoshi; Matsumoto, Kiyoshi
2011-07-15
A method for the determination of water-soluble vitamins using a colorimetric microbial viability assay based on the reduction of the tetrazolium salt {2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8)} via 2-methyl-1,4-napthoquinone (NQ) was developed. Measurement conditions were optimized for the microbiological determination of water-soluble vitamins, such as vitamin B(6), biotin, folic acid, niacin, and pantothenic acid, using microorganisms that have a water-soluble vitamin requirement. A linear relationship between absorbance and water-soluble vitamin concentration was obtained. The proposed method was applied to determine the concentration of vitamin B(6) in various foodstuffs. There was good agreement between vitamin B(6) concentrations determined after 24h using the WST-8 colorimetric method and those obtained after 48h using a conventional method. The results suggest that the WST-8 colorimetric assay is a useful method for the rapid determination of water-soluble vitamins in a 96-well microtiter plate. Copyright © 2011 Elsevier Ltd. All rights reserved.
An Illumination-Adaptive Colorimetric Measurement Using Color Image Sensor
NASA Astrophysics Data System (ADS)
Lee, Sung-Hak; Lee, Jong-Hyub; Sohng, Kyu-Ik
An image sensor for a use of colorimeter is characterized based on the CIE standard colorimetric observer. We use the method of least squares to derive a colorimetric characterization matrix between RGB output signals and CIE XYZ tristimulus values. This paper proposes an adaptive measuring method to obtain the chromaticity of colored scenes and illumination through a 3×3 camera transfer matrix under a certain illuminant. Camera RGB outputs, sensor status values, and photoelectric characteristic are used to obtain the chromaticity. Experimental results show that the proposed method is valid in the measuring performance.
Colorimetric micro-assay for accelerated screening of mould inhibitors
Carol A. Clausen; Vina W. Yang
2013-01-01
Since current standard laboratory methods are time-consuming macro-assays that rely on subjective visual ratings of mould growth, rapid and quantitative laboratory methods are needed to screen potential mould inhibitors for use in and on cellulose-based products. A colorimetric micro-assay has been developed that uses XTT tetrazolium salt to enzymatically assess...
Basic methods for measuring the reflectance color of iron oxides
NASA Astrophysics Data System (ADS)
Pospisil, Jaroslav; Hrdy, Jan; Hrdy Jan, Jr.
2007-06-01
The main contribution of the present article consists in coherent description and interpretation of the principles of basic measuring methods and colorimeters for color classification and evaluation of light reflecting samples containing iron oxides. The chosen relevant theoretical background is based on the CIE tristimulus colorimetric system (X,Y,Z), the CIE colorimetric system (L*,a*,b*) and the Munsell colorimetric system (H,V,C). As an example of color identification and evaluation, some specific mathematical and graphical relationships between the soil redness rate and the corresponding hematite content are shown.
Wang, Xinhao; Chang, Te-Wei; Lin, Guohong; Gartia, Manas Ranjan; Liu, Gang Logan
2017-01-03
Colorimetric sensors usually suffer due to errors from variation in light source intensity, the type of light source, the Bayer filter algorithm, and the sensitivity of the camera to incoming light. Here, we demonstrate a self-referenced portable smartphone-based plasmonic sensing platform integrated with an internal reference sample along with an image processing method to perform colorimetric sensing. Two sensing principles based on unique nanoplasmonics enabled phenomena from a nanostructured plasmonic sensor, named as nanoLCA (nano Lycurgus cup array), were demonstrated here for colorimetric biochemical sensing: liquid refractive index sensing and optical absorbance enhancement sensing. Refractive indices of colorless liquids were measured by simple smartphone imaging and color analysis. Optical absorbance enhancement in the colorimetric biochemical assay was achieved by matching the plasmon resonance wavelength with the chromophore's absorbance peak wavelength. Such a sensing mechanism improved the limit of detection (LoD) by 100 times in a microplate reader format. Compared with a traditional colorimetric assay such as urine testing strips, a smartphone plasmon enhanced colorimetric sensing system provided 30 times improvement in the LoD. The platform was applied for simulated urine testing to precisely identify the samples with higher protein concentration, which showed potential point-of-care and early detection of kidney disease with the smartphone plasmonic resonance sensing system.
Cheng, Ruojie; Liu, Siyao; Shi, Huijie; Zhao, Guohua
2018-01-05
A highly sensitive, specific and simple colorimetric sensor based on aptamer was established for the detection of polychlorinated biphenyls (PCB 77). The use of unmodified gold nanoparticles as a colorimetric probe for aptamer sensors enabled the highly sensitive and selective detection of polychlorinated biphenyls (PCB 77). A linear range of 0.5nM to 900nM was obtained for the colorimetric assay with a minimum detection limit of 0.05nM. In addition, by the methods of circular dichroism, UV and naked eyes, we found that the 35 base fragments retained after cutting 5 bases from the 5 'end of aptamer plays the most significant role in the PCB 77 specific recognition process. We found a novel way to truncated nucleotides to optimize the detection of PCB 77, and the selected nucleotides also could achieve high affinity with PCB 77. At the same time, the efficient detection of the PCB 77 by our colorimetric sensor in the complex environmental water samples was realized, which shows a good application prospect. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Xiong, Yanmei; Zhang, Yuyan; Rong, Pengfei; Yang, Jie; Wang, Wei; Liu, Dingbin
2015-09-01
We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose.We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose. Electronic supplementary information (ESI) available: Experimental section and additional figures. See DOI: 10.1039/c5nr03758a
Arnaud, J; Chappuis, P; Zawislak, R; Houot, O; Jaudon, M C; Bienvenu, F; Bureau, F
1993-02-01
An interlaboratory collaborative trial was conducted on the determination of serum copper using two different methods, based on colorimetry (test combination Copper, Boehringer Mannheim, Mannheim, Germany) and flame atomic absorption spectrometry (FAAS). The general performance of the colorimetric method was below that of FAAS, except for sensitivity and linear range, as assessed by detection limit (0.44 versus 1.32 mumol/L) and upper limit of linearity (150 versus 50 mumol/L). The range of the between-run CVs and the recovery of standard additions were, respectively, 2.3-11.9% and 92-127% for the colorimetric method and 1.1-6.0% and 93-101% for the FAAS method. Interferences were minimal with both methods. The two techniques correlated satisfactorily (the correlation coefficients ranged from 0.945-0.970 among laboratories) but the colorimetric assay exhibited slightly higher results than the FAAS method. Each method was transferable among laboratories.
Detection of proteins using a colorimetric bio-barcode assay.
Nam, Jwa-Min; Jang, Kyung-Jin; Groves, Jay T
2007-01-01
The colorimetric bio-barcode assay is a red-to-blue color change-based protein detection method with ultrahigh sensitivity. This assay is based on both the bio-barcode amplification method that allows for detecting miniscule amount of targets with attomolar sensitivity and gold nanoparticle-based colorimetric DNA detection method that allows for a simple and straightforward detection of biomolecules of interest (here we detect interleukin-2, an important biomarker (cytokine) for many immunodeficiency-related diseases and cancers). The protocol is composed of the following steps: (i) conjugation of target capture molecules and barcode DNA strands onto silica microparticles, (ii) target capture with probes, (iii) separation and release of barcode DNA strands from the separated probes, (iv) detection of released barcode DNA using DNA-modified gold nanoparticle probes and (v) red-to-blue color change analysis with a graphic software. Actual target detection and quantification steps with premade probes take approximately 3 h (whole protocol including probe preparations takes approximately 3 days).
Zhang, Xianxia; Xiao, Kunyi; Cheng, Liwei; Chen, Hui; Liu, Baohong; Zhang, Song; Kong, Jilie
2014-06-03
Rapid and efficient detection of cancer cells at their earliest stages is one of the central challenges in cancer diagnostics. We developed a simple, cost-effective, and highly sensitive colorimetric method for visually detecting rare cancer cells based on cell-triggered cyclic enzymatic signal amplification (CTCESA). In the absence of target cells, hairpin aptamer probes (HAPs) and linker DNAs stably coexist in solution, and the linker DNA assembles DNA-AuNPs, producing a purple solution. In the presence of target cells, the specific binding of HAPs to the target cells triggers a conformational switch that results in linker DNA hybridization and cleavage by nicking endonuclease-strand scission cycles. Consequently, the cleaved fragments of linker DNA can no longer assemble into DNA-AuNPs, resulting in a red color. UV-vis spectrometry and photograph analyses demonstrated that this CTCESA-based method exhibited selective and sensitive colorimetric responses to the presence of target CCRF-CEM cells, which could be detected by the naked eye. The linear response for CCRF-CEM cells in a concentration range from 10(2) to 10(4) cells was obtained with a detection limit of 40 cells, which is approximately 20 times lower than the detection limit of normal AuNP-based methods without amplification. Given the high specificity and sensitivity of CTCESA, this colorimetric method provides a sensitive, label-free, and cost-effective approach for early cancer diagnosis and point-to-care applications.
Zargar, Behrooz; Hatamie, Amir
2013-04-01
Isoniazid is an important antibiotic, which is widely used to treat tuberculosis. This study presents a colorimetric method for the determination of Isoniazid based on localized surface plasmon resonance (LSPR) property of gold nanoparticles. An LSPR band is produced by reducing gold ions in solution using Isoniazid as the reducing agent. Influences of the following relevant variables were examined and optimized in the experiment, formation time of gold nanoparticles, pH, buffer and stabilizer. These tests demonstrated that under optimum conditions the absorbance of Au nanoparticles at 530 nm related linearly to the concentration of Isoniazid in the range of 1.0-8.0 μg mL(-1) with a detection limit of 0.98 μg mL(-1). This colorimetric method has been successfully applied to the determine Isoniazid in tablets and spiked serum samples. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for analysis of Isoniazid. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zargar, Behrooz; Hatamie, Amir
2013-04-01
Isoniazid is an important antibiotic, which is widely used to treat tuberculosis. This study presents a colorimetric method for the determination of Isoniazid based on localized surface plasmon resonance (LSPR) property of gold nanoparticles. An LSPR band is produced by reducing gold ions in solution using Isoniazid as the reducing agent. Influences of the following relevant variables were examined and optimized in the experiment, formation time of gold nanoparticles, pH, buffer and stabilizer. These tests demonstrated that under optimum conditions the absorbance of Au nanoparticles at 530 nm related linearly to the concentration of Isoniazid in the range of 1.0-8.0 μg mL-1 with a detection limit of 0.98 μg mL-1. This colorimetric method has been successfully applied to the determine Isoniazid in tablets and spiked serum samples. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for analysis of Isoniazid.
Wang, Ying; Zhu, Yingjing; Binyam, Atsebeha; Liu, Misha; Wu, Yinan; Li, Fengting
2016-12-15
A label-free sensing strategy based on the enzyme-mimicking activity of MOF was demonstrated for colorimetric detection of biomolecules. Firstly obvious blue color was observed due to the high efficiency of peroxidase-like catalytic activity of Fe-MIL-88A (an ion-based MOF material) toward 3,3',5,5'-tetramethylbenzidine (TMB). Then in the presence of target biomolecule and corresponding aptamer, the mimetic activity of Fe-MIL-88A can be strongly inhibited and used directly to realize the colorimetric detection. On the basis of the interesting findings, we designed a straightforward, label-free and sensitive colorimetric method for biomolecule detection by using the enzyme mimetic property of MOF coupling with molecular recognition element. Compared with the existed publications, our work breaks the routine way by setting up an inorganic-organic MOF-aptamer hybrid platform for colorimetric determination of biomolecules, expanding the targets scope from H2O2 or glucose to biomolecules. As a proof of concept, thrombin and thrombin aptamer was used as a model analyte. The limit of detection of 10nM can be achieved with naked eyes and ultrahigh selectivity of thrombin toward numerous interfering substances with 10-fold concentration was demonstrated significantly. Of note, the method was further applied for the detection of thrombin in human serum samples, showing the results in agreement with those values obtained in an immobilization buffer by the colorimetric method. This inorganic-organic MOF-aptamer sensing strategy may in principle be universally applicable for the detection of a range of environmental or biomedical molecules of interests. Copyright © 2016 Elsevier B.V. All rights reserved.
Field demonstration of on-site analytical methods for TNT and RDX in ground water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, H.; Ferguson, G.; Markos, A.
1996-12-31
A field demonstration was conducted to assess the performance of eight commercially-available and emerging colorimetric, immunoassay, and biosensor on-site analytical methods for explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water and leachate at the Umatilla Army Depot Activity, Hermiston, Oregon and US Naval Submarine Base, Bangor, Washington, Superfund sites. Ground water samples were analyzed by each of the on-site methods and results compared to laboratory analysis using high performance liquid chromatography (HPLC) with EPA SW-846 Method 8330. The commercial methods evaluated include the EnSys, Inc., TNT and RDX colorimetric test kits (EPA SW-846 Methods 8515 and 8510) with amore » solid phase extraction (SPE) step, the DTECH/EM Science TNT and RDX immunoassay test kits (EPA SW-846 Methods 4050 and 4051), and the Ohmicron TNT immunoassay test kit. The emerging methods tested include the antibody-based Naval Research Laboratory (NRL) Continuous Flow Immunosensor (CFI) for TNT and RDX, and the Fiber Optic Biosensor (FOB) for TNT. Accuracy of the on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison criteria. Over the range of conditions tested, the colorimetric methods for TNT and RDX showed the highest accuracy of the emerging methods for TNT and RDX. The colorimetric method was selected for routine ground water monitoring at the Umatilla site, and further field testing on the NRL CFI and FOB biosensors will continue at both Superfund sites.« less
Üzer, Ayşem; Can, Ziya; Akın, Ilknur; Erçağ, Erol; Apak, Reşat
2014-01-07
The heterocyclic nitramine compounds, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), are two most important military-purpose high explosives. Differentiation of RDX and HMX with colorimetric methods of determination has not yet been made because of their similar chemical structures. In this study, a sensitive colorimetric method for the determination of RDX and HMX was proposed on the basis of differential kinetics in the hydrolysis of the two compounds (yielding nitrite as a product) followed by their colorimetric determination using 4-aminothiophenol (4-ATP) modified gold nanoparticles (AuNPs) and naphthylethylene diamine (NED) as coupling agent for azo-dye formation, abbreviated as "4-ATP-AuNP+NED" colorimetric method. After alkaline hydrolysis in a 1 M Na2CO3 + 0.04 M NaOH mixture solution at room temperature, only RDX (but not HMX) was hydrolyzed to give a sufficient colorimetric response in neutralized solution, the molar absorptivity (ε) at 565 nm and the limit of detection (LOD) for RDX being (17.6 ± 1.3) × 10(3) L mol(-1) cm(-1) and 0.55 μg mL(-1), respectively. On the other hand, hot water bath (at 60 °C) hydrolysis enabled both nitramines, RDX and HMX, to give substantial colorimetric responses; i.e., ε and LOD for RDX were (32.8 ± 0.5) × 10(3) L mol(-1)cm(-1) and 0.20 μg mL(-1) and for HMX were (37.1 ± 2.8) × 10(3) L mol(-1)cm(-1) and 0.24 μg mL(-1), respectively. Unlike other AuNP-based nitrite sensors in the literature showing absorbance quenching within a relatively narrow concentration range, the developed sensor operated with an absorbance increase over a wide range of nitrite. Synthetic mixtures of (RDX + HMX) gave additive responses, and the proposed method was statistically validated against HPLC using nitramine mixtures.
NASA Astrophysics Data System (ADS)
Zhu, Yiting; Narendran, Nadarajah; Tan, Jianchuan; Mou, Xi
2014-09-01
The organic light-emitting diode (OLED) has demonstrated its novelty in displays and certain lighting applications. Similar to white light-emitting diode (LED) technology, it also holds the promise of saving energy. Even though the luminous efficacy values of OLED products have been steadily growing, their longevity is still not well understood. Furthermore, currently there is no industry standard for photometric and colorimetric testing, short and long term, of OLEDs. Each OLED manufacturer tests its OLED panels under different electrical and thermal conditions using different measurement methods. In this study, an imaging-based photometric and colorimetric measurement method for OLED panels was investigated. Unlike an LED that can be considered as a point source, the OLED is a large form area source. Therefore, for an area source to satisfy lighting application needs, it is important that it maintains uniform light level and color properties across the emitting surface of the panel over a long period. This study intended to develop a measurement procedure that can be used to test long-term photometric and colorimetric properties of OLED panels. The objective was to better understand how test parameters such as drive current or luminance and temperature affect the degradation rate. In addition, this study investigated whether data interpolation could allow for determination of degradation and lifetime, L70, at application conditions based on the degradation rates measured at different operating conditions.
NASA Astrophysics Data System (ADS)
Amirjani, Amirmostafa; Bagheri, Mozhgan; Heydari, Mojgan; Hesaraki, Saeed
2016-09-01
In this work, a rapid and simple colorimetric method based on the surface plasmon resonance of silver nanoparticles (AgNPs) was developed for the detection of the drug Timolol. The method used is based on the interaction of Timolol with the surface of the as-synthesized AgNPs, which promotes aggregation of the nanoparticles. This aggregation exploits the surface plasmon resonance through the electric dipole-dipole interaction and coupling among the agglomerated particles, hence bringing forth distinctive changes in the spectra as well as the color of colloidal silver. UV-vis spectrophotometery was used to monitor the changes of the localized surface plasmon resonance of AgNPs at wavelengths of 400 and 550 nm. The developed colorimetric sensor has a wide dynamic range of 1.0 × 10-7 M-1.0 × 10-3 M for detection of Timolol with a low detection limit of 1.2 × 10-6 M. The proposed method was successfully applied for the determination of Timolol concentration in ophthalmic eye-drop solution with a response time lower than 40 s.
Silver nanoparticles-based colorimetric array for the detection of Thiophanate-methyl
NASA Astrophysics Data System (ADS)
Zheng, Mingda; Wang, Yingying; Wang, Chenge; Wei, Wei; Ma, Shuang; Sun, Xiaohan; He, Jiang
2018-06-01
A simple and selective colorimetric sensor based on citrate capped silver nanoparticles (Cit-AgNPs) is proposed for the detection of Thiophanate-methyl (TM) with high sensitivity and selectivity. The method based on the color change of Cit-AgNPs from yellow to cherry red with the addition of TM to Cit-AgNPs that caused a red-shift on the surface plasmon resonance (SPR) band from 394 nm to 525 nm due to the hydrogen-bonding and substitution. The density functional theory (DFT) method was also calculated the interactions between the TM and citrate ions. Under the optimized conditions, a linear relationship between the absorption ratio (A525nm/A394nm) and TM concentration was found in the range of 2-100 μM with correlation coefficient (R2) of 0.988. The detection limit of TM was 0.12 μM by UV-vis spectrometer. Moreover, the applicability of colorimetric sensor is successfully verified by the detection of TM in environmental samples with good recoveries.
Zhang, Decai; Wang, Weijia; Dong, Qian; Huang, Yunxiu; Wen, Dongmei; Mu, Yuejing; Yuan, Yong
2017-12-21
An isothermal colorimetric method is described for amplified detection of the CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on (a) target DNA-triggered unlabeled molecular beacon (UMB) termini binding, and (b) exonuclease III (Exo III)-assisted target recycling, and (c) hemin/G-quadruplex (DNAzyme) based signal amplification. The specific binding of target to the G-quadruplex sequence-locked UMB triggers the digestion of Exo III. This, in turn, releases an active G-quadruplex segment and target DNA for successive hybridization and cleavage. The Exo III impellent recycling of targets produces numerous G-quadruplex sequences. These further associate with hemin to form DNAzymes and hence will catalyze H 2 O 2 -mediated oxidation of the chromogenic enzyme substrate ABTS 2- causing the formation of a green colored product. This finding enables a sensitive colorimetric determination of GMO DNA (at an analytical wavelength of 420 nm) at concentrations as low as 0.23 nM. By taking advantage of isothermal incubation, this method does not require sophisticated equipment or complicated syntheses. Analyses can be performed within 90 min. The method also discriminates single base mismatches. In our perception, it has a wide scope in that it may be applied to the detection of many other GMOs. Graphical abstract An isothermal and sensitive colorimetric method is described for amplified detection of CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on target DNA-triggered molecular beacon (UMB) termini-binding and exonuclease III assisted target recycling, and on hemin/G-quadruplex (DNAzyme) signal amplification.
Li, Hongkun; Guo, Jiajia; Ping, Hong; Liu, Lurui; Zhang, Minwei; Guan, Fengrui; Sun, Chunyan; Zhang, Qian
2011-12-15
With citrate-coated Au nanoparticles as colorimetric probe, a novel visual method for rapid assay of organophosphorus pesticides has been developed. The assay principle is based on catalytic hydrolysis of acetylthiocholine into thiocholine by acetylcholinesterase, which induces the aggregation of Au nanoparticles and the color change from claret-red to purple or even grey. The original plasmon absorption of Au nanoparticles at 522 nm decreases, and simultaneously, a new absorption band appears at 675 nm. The irreversible inhibition of organophosphorus pesticides on acetylcholinesterase prevents aggregation of Au nanoparticles. Under optimum conditions, the absorbance at 522 nm of Au nanoparticles is related linearly to the concentration of mathamidophos in the range of 0.02-1.42 μg/mL with a detection limit of 1.40 ng/mL. This colorimetric method has been successfully utilized to detect mathamidophos in vegetables with satisfactory results. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for the analysis of organophosphorus pesticides. Copyright © 2011 Elsevier B.V. All rights reserved.
Martín-Alonso, Manuel; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos
2018-03-13
This work reports on the implementation of gold nanorods (AuNRs) in headspace solvent microextraction for colorimetric determination of volatile analyte derivatives in a single drop. The exposure of AuNRs to both H 2 Se and elemental mercury (Hg 0 ) results in a shift of the longitudinal plasmonic band, unlike a number of volatiles. Accordingly, a method is reported for the determination of Hg 0 with potential applicability to the determination of thiomersal (sodium ethylmercurithiosalicylate). It is based on the photochemical decomposition of thiomersal into Hg(II) and subsequent exposure of AuNRs-containing microdrop to in situ generated Hg 0 . Colorimetric analysis of the enriched drop was carried out without dilution by means of a cuvetteless microvolume UV-vis spectrometer. Under optimal conditions, the limit of detection was 0.5 ng mL -1 (as Hg). The repeatability, expressed as relative standard deviation, was 8.4% (for n = 10). AuNRs exposed to increasing concentrations of the analyte were characterized by means of transmission electron microscopy and UV-vis spectrophotometry to ascertain the mechanism of detection. The method was finally applied to the determination of thiomersal in various pharmaceutical samples and showed quantitative recoveries. Graphical abstract Schematic illustration of a miniaturized colorimetric method based on the use of a microdrop of gold nanorods (AuNRs) for thiomersal determination in pharmaceuticals. It is based on the photochemical decomposition of thiomersal and subsequent Hg 0 generation with in-drop amalgamation.
Colorimetric detection for paper-based biosensing applications
NASA Astrophysics Data System (ADS)
Brink, C.; Joubert, T.-H.
2016-02-01
Research on affordable point-of-care health diagnostics is rapidly advancing1. Colorimetric biosensor applications are typically qualitative, but recently the focus has been shifted to quantitative measurements2,3. Although numerous qualitative point-of-care (POC) health diagnostic devices are available, the challenge exists of developing a quantitative colorimetric array reader system that complies with the ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, Deliverable to end-users) principles of the World Health Organization4. This paper presents a battery powered 8-bit tonal resolution colorimetric sensor circuit for paper microfluidic assays using low cost photo-detection circuitry and a low-power LED light source. A colorimetric 3×3-pixel array reader was developed for rural environments where resources and personnel are limited. The device sports an ultralow-power E-ink paper display. The colorimetric device includes integrated GPS functionality and EEPROM memory to log measurements with geo-tags for possible analysis of regional trends. The device competes with colour intensity measurement techniques using smartphone cameras, but proves to be a cheaper solution, compensating for the typical performance variations between cameras of different brands of smartphones. Inexpensive methods for quantifying bacterial assays have been shown using desktop scanners, which are not portable, and cameras, which suffer severely from changes in ambient light in different environments. Promising colorimetric detection results have been demonstrated using devices such as video cameras5, digital colour analysers6, flatbed scanners7 or custom portable readers8. The major drawback of most of these methods is the need for specialized instrumentation and for image analysis on a computer.
Brotto, Laura; Battistutta, Franco; Tat, Lara; Comuzzo, Piergiorgio; Zironi, Roberto
2010-03-24
Some modifications to a previous nondestructive colorimetric method that permits evaluation of the oxygen diffusion rate through wine closures were proposed. The method is based on the reaction of indigo carmine solution with oxygen and the tristimulus measurement of the consequent color change. Simplified preparation and measurement procedures were set up, allowing the analysis of a large number of samples simultaneously. The method was applied to the evaluation of the variability within the lot of 20 different types of stoppers (synthetic, produced by molding, and natural cork). The closures were tested at a storage temperature of 26 degrees C. With regard to oxygen permeability, the natural cork stopper showed a low homogeneity within the lot, especially during the first month after bottling, whereas the synthetic closure showed a greater steadiness in the performance. The limits of the colorimetric method were also analyzed, and three possible causes of degradation of the indigo carmine solution were identified: oxygen, light, and heat.
Tsukatani, Tadayuki; Suenaga, Hikaru; Higuchi, Tomoko; Shiga, Masanobu; Noguchi, Katsuya; Matsumoto, Kiyoshi
2011-01-01
Bacteria are fundamentally divided into two groups: Gram-positive and Gram-negative. Although the Gram stain and other techniques can be used to differentiate these groups, some issues exist with traditional approaches. In this study, we developed a method for differentiating Gram-positive and -negative bacteria using a colorimetric microbial viability assay based on the reduction of the tetrazolium salt {2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium, monosodium salt} (WST-8) via 2-methyl-1,4-napthoquinone with a selection medium. We optimized the composition of the selection medium to allow the growth of Gram-negative bacteria while inhibiting the growth of Gram-positive bacteria. When the colorimetric viability assay was carried out in a selection medium containing 0.5µg/ml crystal violet, 5.0 µg/ml daptomycin, and 5.0µg/ml vancomycin, the reduction in WST-8 by Gram-positive bacteria was inhibited. On the other hand, Gram-negative bacteria produced WST-8-formazan in the selection medium. The proposed method was also applied to determine the Gram staining characteristics of bacteria isolated from various foodstuffs. There was good agreement between the results obtained using the present method and those obtained using a conventional staining method. These results suggest that the WST-8 colorimetric assay with selection medium is a useful technique for accurately differentiating Gram-positive and -negative bacteria.
NASA Astrophysics Data System (ADS)
Chavada, Vijay D.; Bhatt, Nejal M.; Sanyal, Mallika; Shrivastav, Pranav S.
2017-01-01
In this article we report a novel method for colorimetric sensing and selective determination of a non-chromophoric drug-azithromycin, which lacks native absorbance in the UV-Visible region using unmodified silver nanoparticles (AgNPs). The citrate-capped AgNps dispersed in water afforded a bright yellow colour owing to the electrostatic repulsion between the particles due to the presence of negatively charged surface and showed surface plasmon resonance (SPR) band at 394 nm. Addition of positively charged azithromycin at a concentration as low as 0.2 μM induced rapid aggregation of AgNPs by neutralizing the negative charge on the particle surface. This phenomenon resulted in the colour change from bright yellow to purple which could be easily observed by the naked eye. This provided a simple platform for rapid determination of azithromycin based on colorimetric measurements. The factors affecting the colorimetric response like pH, volume of AgNPs suspension and incubation time were suitably optimized. The validated method was found to work efficiently in the established concentration range of 0.2-100.0 μM using two different calibration models. The selectivity of the method was also evaluated by analysis of nanoparticles-aggregation response upon addition of several anions, cations and some commonly prescribed antibiotics. The method was successfully applied for the analysis of azithromycin in pharmaceuticals and spiked human plasma samples with good accuracy and precision. The simplicity, efficiency and cost-effectiveness of the method hold tremendous potential for the analysis of such non-chromophoric pharmaceuticals.
Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics.
Tang, Longhua; Li, Jinghong
2017-07-28
Colorimetric detection of target analytes with high specificity and sensitivity is of fundamental importance to clinical and personalized point-of-care diagnostics. Because of their extraordinary optical properties, plasmonic nanomaterials have been introduced into colorimetric sensing systems, which provide significantly improved sensitivity in various biosensing applications. Here we review the recent progress on these plasmonic nanoparticles-based colorimetric nanosensors for ultrasensitive molecular diagnostics. According to their different colorimetric signal generation mechanisms, these plasmonic nanosensors are classified into two categories: (1) interparticle distance-dependent colorimetric assay based on target-induced forming cross-linking assembly/aggregate of plasmonic nanoparticles; and (2) size/morphology-dependent colorimetric assay by target-controlled growth/etching of the plasmonic nanoparticles. The sensing fundamentals and cutting-edge applications will be provided for each of them, particularly focusing on signal generation and/or amplification mechanisms that realize ultrasensitive molecular detection. Finally, we also discuss the challenge and give our future perspective in this emerging field.
NASA Astrophysics Data System (ADS)
Chen, Huan; Li, Zhihong; Liu, Xueting; Zhong, Jianhai; Lin, Tianran; Guo, Liangqia; Fu, Fengfu
2017-10-01
The peroxidase-like catalytic activity of MoS2 nanomaterials has been utilized for colorimetric bioassays and medical diagnostics. However, the application of peroxidase-like catalytic activity of MoS2 nanomaterials in environmental analysis was seldom explored. Herein, copper ions were found to inhibit the peroxidase-like catalytic activity of MoS2 nanosheets, which can catalyze the oxidation of 3, 3‧, 5, 5‧-tetramethylbenzidine by H2O2 to produce a colorimetric product. Based on this finding, a simple sensitive colorimetric method for the detection of copper ions was developed. In the presence of copper ions, the absorbance and color of the solution decreased with the increasing concentration of copper ions. The color of the solution can be used to semi-quantitative on-site assay of copper ions by naked eyes. A linear relationship between the absorbance and the concentration of copper ions was observed in the range of 0.4-4.0 μmol L- 1 with a detection limit of 92 nmol L- 1, which was much lower than the maximum contaminant level of copper in drinking water legislated by the Environmental Protection Agency of USA and the World Health Organization. The method was applied to detect copper ions in environmental water samples with satisfactory results.
NASA Astrophysics Data System (ADS)
Cao, Bin; Liao, Ningfang; Li, Yasheng; Cheng, Haobo
2017-05-01
The use of spectral reflectance as fundamental color information finds application in diverse fields related to imaging. Many approaches use training sets to train the algorithm used for color classification. In this context, we note that the modification of training sets obviously impacts the accuracy of reflectance reconstruction based on classical reflectance reconstruction methods. Different modifying criteria are not always consistent with each other, since they have different emphases; spectral reflectance similarity focuses on the deviation of reconstructed reflectance, whereas colorimetric similarity emphasizes human perception. We present a method to improve the accuracy of the reconstructed spectral reflectance by adaptively combining colorimetric and spectral reflectance similarities. The different exponential factors of the weighting coefficients were investigated. The spectral reflectance reconstructed by the proposed method exhibits considerable improvements in terms of the root-mean-square error and goodness-of-fit coefficient of the spectral reflectance errors as well as color differences under different illuminants. Our method is applicable to diverse areas such as textiles, printing, art, and other industries.
Highly selective colorimetric bacteria sensing based on protein-capped nanoparticles.
Qiu, Suyan; Lin, Zhenyu; Zhou, Yaomin; Wang, Donggen; Yuan, Lijuan; Wei, Yihua; Dai, Tingcan; Luo, Linguang; Chen, Guonan
2015-02-21
A rapid and cost-effective colorimetric sensor has been developed for the detection of bacteria (Bacillus subtilis was selected as an example). The sensor was designed to rely on lysozyme-capped AuNPs with the advantages of effective amplification and high specificity. In the sensing system, lysozyme was able to bind strongly to Bacillus subtilis, which effectively induced a color change of the solution from light purple to purplish red. The lowest concentration of Bacillus subtilis detectable by the naked eye was 4.5 × 10(3) colony-forming units (CFU) mL(-1). Similar results were discernable from UV-Vis absorption measurements. A good specificity was observed through a statistical analysis method using the SPSS software (version 17.0). This simple colorimetric sensor may therefore be a rapid and specific method for a bacterial detection assay in complex samples.
Tian, Kun; Siegel, Gene; Tiwari, Ashutosh
2017-02-01
The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Anthon, Gordon E; Barrett, Diane M
2008-09-01
A simple procedure for determining the galacturonic acid and methanol contents of soluble and insoluble pectins, relying on enzymatic pectin hydrolysis and colorimetric quantification, is described. Pectin samples are incubated with a commercial pectinase preparation, Viscozyme, then the galacturonic acid content of the hydrolyzed pectin is quantified colorimetrically using a modification of the Cu reduction procedure originally described by Avigad and Milner. This modification, substituting the commonly used Folin-Ciocalteau reagent for the arsenic containing Nelson reagent, gives a response that is linear, sensitive, and selective for uronic acids over neutral sugars. This method also avoids the use of concentrated acids needed for the commonly used m-phenylphenol method. Methanol, released by the action of the pectin methylesterase found in the Viscozyme, is quantified using alcohol oxidase and Purpald. This combined enzymatic and colorimetric procedure correctly determined the galacturonic acid and methanol content of purified, soluble citrus pectin. Application of the procedure to water insoluble pectins was evaluated with water insoluble material from apples and oranges. In both cases good agreement was obtained between this method and commonly used methods based on chemical pectin hydrolysis. Good agreement between these procedures was also found in the analysis of both soluble and insoluble pectins from several tomato products. Copyright © 2008 Elsevier Ltd. All rights reserved.
Enzyme-free colorimetric detection systems based on the DNA strand displacement competition reaction
NASA Astrophysics Data System (ADS)
Zhang, Z.; Birkedal, V.; Gothelf, K. V.
2016-05-01
The strand displacement competition assay is based on the dynamic equilibrium of the competitive hybridization of two oligonucleotides (A and B) to a third oligonucleotide (S). In the presence of an analyte that binds to a specific affinity-moiety conjugated to strand B, the equilibrium shifts, which can be detected by a shift in the fluorescence resonance energy transfer signal between dyes attached to the DNA strands. In the present study we have integrated an ATP aptamer in the strand B and demonstrated the optical detection of ATP. Furthermore we explore a new readout method using a split G-quadruplex DNAzyme for colorimetric readout of the detection of streptavidin by the naked eye. Finally, we integrate the whole G-quadruplex DNAzyme system in a single DNA strand and show that it is applicable to colorimetric detection.
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays.
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-19
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.
Hu, Qinqin; Fu, Yingchun; Xu, Xiahong; Qiao, Zhaohui; Wang, Ronghui; Zhang, Ying; Li, Yanbin
2016-02-07
Acrylamide (AA), a neurotoxin and a potential carcinogen, has been found in various thermally processed foods such as potato chips, biscuits, and coffee. Simple, cost-effective, and sensitive methods for the rapid detection of AA are needed to ensure food safety. Herein, a novel colorimetric method was proposed for the visual detection of AA based on a nucleophile-initiated thiol-ene Michael addition reaction. Gold nanoparticles (AuNPs) were aggregated by glutathione (GSH) because of a ligand-replacement, accompanied by a color change from red to purple. In the presence of AA, after the thiol-ene Michael addition reaction between GSH and AA with the catalysis of a nucleophile, the sulfhydryl group of GSH was consumed by AA, which hindered the subsequent ligand-replacement and the aggregation of AuNPs. Therefore, the concentration of AA could be determined by the visible color change caused by dispersion/aggregation of AuNPs. This new method showed high sensitivity with a linear range from 0.1 μmol L(-1) to 80 μmol L(-1) and a detection limit of 28.6 nmol L(-1), and especially revealed better selectivity than the fluorescence sensing method reported previously. Moreover, this new method was used to detect AA in potato chips with a satisfactory result in comparison with the standard methods based on chromatography, which indicated that the colorimetric method can be expanded for the rapid detection of AA in thermally processed foods.
NASA Astrophysics Data System (ADS)
Zhang, Aiqin; Yang, Yamin; Zhai, Guangmei; Jia, Husheng; Xu, Bingshe
2016-02-01
In this work, a method of tuning the chromaticity of the emission color of the copolymers containing Eu(III), Tb(III), Be(II) ions based on colorimetric principle was proposed. The technological route from coordination to copolymerization was employed to obtain the white light macromolecular phosphor. The three primary color monomers have been synthesized and their Commission Internationale de L'Eclairage (CIE) coordinates are respectively (0.540, 0.314), (0.231, 0.463), and (0.161, 0.054). The molar feed ratios of the three primary color monomers were calculated from the CIE coordinates based on colorimetric principle. Serial copolymers have been synthesized by free radical copolymerization of the three primary color monomers and methyl methacrylate. The quantum efficiency of the copolymers was higher than that of the complex monomers. The complexes were directly boned to the polymer chain, in which the energy transfer was reduced significantly compared to the doped-polymers. The experimental values of copolymers' CIE coordinates were located in the white light region in good agreement with theoretical values. The results indicate that the chromaticity of the emission color of the copolymers containing Eu(III), Tb(III), Be(II) ions could be tuned by theoretical calculation based on colorimetric principle.
Color digital halftoning taking colorimetric color reproduction into account
NASA Astrophysics Data System (ADS)
Haneishi, Hideaki; Suzuki, Toshiaki; Shimoyama, Nobukatsu; Miyake, Yoichi
1996-01-01
Taking colorimetric color reproduction into account, the conventional error diffusion method is modified for color digital half-toning. Assuming that the input to a bilevel color printer is given in CIE-XYZ tristimulus values or CIE-LAB values instead of the more conventional RGB or YMC values, two modified versions based on vector operation in (1) the XYZ color space and (2) the LAB color space were tested. Experimental results show that the modified methods, especially the method using the LAB color space, resulted in better color reproduction performance than the conventional methods. Spatial artifacts that appear in the modified methods are presented and analyzed. It is also shown that the modified method (2) with a thresholding technique achieves a good spatial image quality.
Lee, Mei-Feng; Chen, Yen-Hsu; Hsu, Hui-Jine; Peng, Chien-Fang
2010-10-01
In this study, we designed a simple and rapid colorimetric detection method, a one-tube loop-mediated isothermal amplification (LAMP)-PCR-hybridization-restriction endonuclease-ELISA [one-tube LAMP-PCR-HY-RE-ELISA] system, to detect resistance to isoniazid, ethambutol and streptomycin in strains of Mycobacterium tuberculosis isolated from clinical specimens. The clinical performance of this method for detecting isoniazid-resistant, ethambutol-resistant and streptomycin-resistant isolates of M. tuberculosis showed 98.9%, 94.3% and 93.8%, respectively. This assay is rapid and convenient that can be performed within one working day. One-tube LAMP-PCR-HY-RE-ELISA system was designed based on hot spot point mutations in target drug-resistant genes, using LAMP-PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA. In this study, LAMP assay was used to amplify DNA from drug-resistant M. tuberculosis, and ELISA was used for colorimetrical determination. This assay will be a useful tool for rapid diagnosis of mutant codons in strains of M. tuberculosis for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. A simple sample preparation in conjunction with a rapid screening method possesses the desired c...
DNA aptamer-based colorimetric detection platform for Salmonella Enteritidis.
Bayraç, Ceren; Eyidoğan, Füsun; Avni Öktem, Hüseyin
2017-12-15
Food safety is a major issue to protect public health and a key challenge is to find detection methods for identification of hazards in food. Food borne infections affects millions of people each year and among pathogens, Salmonella Enteritidis is most widely found bacteria causing food borne diseases. Therefore, simple, rapid, and specific detection methods are needed for food safety. In this study, we demonstrated the selection of DNA aptamers with high affinity and specificity against S. Enteritidis via Cell Systematic Evolution of Ligands by Exponential Enrichment (Cell-SELEX) and development of sandwich type aptamer-based colorimetric platforms for its detection. Two highly specific aptamers, crn-1 and crn-2, were developed through 12 rounds of selection with K d of 0.971µM and 0.309µM, respectively. Both aptamers were used to construct sandwich type capillary detection platforms. With the detection limit of 10 3 CFU/mL, crn-1 and crn-2 based platforms detected target bacteria specifically based on color change. This platform is also suitable for detection of S. Enteritidis in complex food matrix. Thus, this is the first to demonstrate use of Salmonella aptamers for development of the colorimetric aptamer-based detection platform in its identification and detection with naked eye in point-of-care. Copyright © 2017 Elsevier B.V. All rights reserved.
Seo, Han-bok; Lee, Seung-Yop
2017-01-01
Structure-dependent colour is caused by the interaction of light with photonic crystal structures rather than pigments. The elytra of longhorn beetles Tmesisternus isabellae appear to be iridescent green in a dry state and turn to red when exposed to humidity. Based on the hygroscopic colouration of the longhorn beetle, we have developed centimeter-scale colorimetric opal films using a novel self-assembly method. The micro-channel assisted assembly technique adopts both natural evaporation and rotational forced drying, enhancing the surface binding of silica particles and the packing density by reducing the lattice constant and structural defects. The fabricated large-scale photonic film changes its structural colour from green to red when exposed to water vapour, similarly to the colorimetric feature of the longhorn beetle. The humidity-dependent colour change of the opal film is shown to be reversible and durable over five-hundred cycles of wetting and drying. PMID:28322307
NASA Astrophysics Data System (ADS)
Seo, Han-Bok; Lee, Seung-Yop
2017-03-01
Structure-dependent colour is caused by the interaction of light with photonic crystal structures rather than pigments. The elytra of longhorn beetles Tmesisternus isabellae appear to be iridescent green in a dry state and turn to red when exposed to humidity. Based on the hygroscopic colouration of the longhorn beetle, we have developed centimeter-scale colorimetric opal films using a novel self-assembly method. The micro-channel assisted assembly technique adopts both natural evaporation and rotational forced drying, enhancing the surface binding of silica particles and the packing density by reducing the lattice constant and structural defects. The fabricated large-scale photonic film changes its structural colour from green to red when exposed to water vapour, similarly to the colorimetric feature of the longhorn beetle. The humidity-dependent colour change of the opal film is shown to be reversible and durable over five-hundred cycles of wetting and drying.
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays
NASA Astrophysics Data System (ADS)
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-01
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications. Electronic supplementary information (ESI) available: Experimental procedures and analytical data are provided. See DOI: 10.1039/c5nr00697j
NASA Technical Reports Server (NTRS)
Diaz, Neil C.; Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.; Rutz, Jeff; Mudgett, Paul; Schultz, John
2004-01-01
Archived water samples collected on the International Space Station (ISS) and returned to Earth for analysis have, in a few instances, contained trace levels of heavy metals. Building on our previous advances using Colorimetric Solid Phase Extraction (C-SPE) as a biocide monitoring technique, we are devising methods for the low level monitoring of nickel(II), lead(II) and other heavy metals. C-SPE is a sorption-spectrophotometric platform based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent that are then quantified on the surface of the membrane using a diffuse reflectance spectrophotometer. Along these lines, we have determined nickel(II) via complexation with dimethylglyoxime (DMG) and begun to examine the analysis of lead(II) by its reaction with 2,5- dimercapto-1,3,4-thiadiazole (DMTD) and 4-(2- pyridylazo)-resorcinol (PAR). These developments are also extending a new variant of C-SPE in which immobilized reagents are being incorporated into this methodology in order to optimize sample reaction conditions and to introduce the colorimetric reagent. This paper describes the status of our development of these two new methods.
A Colorimetric and Fluorescent Chemosensor of Fe3+ Based on an Asymmetrical Squarylium Dye
NASA Astrophysics Data System (ADS)
Lu, Min; Wang, Yue; Li, Ying; Li, Zhongyu; Xu, Song; Yao, Chao
2018-05-01
A novel asymmetrical squarylium-dye-based dual signaling probe was synthesized and found to exhibit colorimetric and fluorescent properties on selective binding towards Fe3+ in ethanol/water (4:1, v/v) solution. The binding constant was determined to be 7.69 × 102 M-1, and the detection limit of SQ was 9.158 × 10-6 M. Most importantly, the 1:2 stoichiometry of the host-guest complexation was confirmed by Job's method. Moreover, the high sensing ability of the receptor towards Fe3+ was also investigated by the electrochemical technique.
Wang, Qian; Pang, Hongchang; Dong, Yongqiang; Chi, Yuwu; Fu, Fengfu
2018-05-10
A kind of single-layer carbon based dots (CDs) with abundant carboxyl functional groups was hybridized with manganese dioxide (MnO 2 ). The resulting nanohybrid is stable and can be well dispersed in water. MnO 2 is capable of oxidizing the substrate 3,3'5,5'-tetramethylbenzidine (TMB) to form a blue product whose absorption (peaking at 655 nm) fades in the presence of glutathione (GSH). A sensitive and selective colorimetric GSH assay was worked out that has a linear response in the 10 to 0.1 µM GSH concentration range, with a 0.095 μM detection limit. The method was applied to the determination of GSH in spiked fetal calf serum where it gave excellent recoveries. Graphical abstract Schematic of the preparation of a nanohybrid composed of manganese dioxide and carbon based dots (MnO 2 /CDs). They can be used for the colorimetric detection of glutathione (GSH) based on the color change of 3,3'5,5'-tetramethylbenzidine (TMB).
Smartphone-based colorimetric analysis for detection of saliva alcohol concentration.
Jung, Youngkee; Kim, Jinhee; Awofeso, Olumide; Kim, Huisung; Regnier, Fred; Bae, Euiwon
2015-11-01
A simple device and associated analytical methods are reported. We provide objective and accurate determination of saliva alcohol concentrations using smartphone-based colorimetric imaging. The device utilizes any smartphone with a miniature attachment that positions the sample and provides constant illumination for sample imaging. Analyses of histograms based on channel imaging of red-green-blue (RGB) and hue-saturation-value (HSV) color space provide unambiguous determination of blood alcohol concentration from color changes on sample pads. A smartphone-based sample analysis by colorimetry was developed and tested with blind samples that matched with the training sets. This technology can be adapted to any smartphone and used to conduct color change assays.
Emergency First Responders' Experience with Colorimetric Detection Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandra L. Fox; Keith A. Daum; Carla J. Miller
2007-10-01
Nationwide, first responders from state and federal support teams respond to hazardous materials incidents, industrial chemical spills, and potential weapons of mass destruction (WMD) attacks. Although first responders have sophisticated chemical, biological, radiological, and explosive detectors available for assessment of the incident scene, simple colorimetric detectors have a role in response actions. The large number of colorimetric chemical detection methods available on the market can make the selection of the proper methods difficult. Although each detector has unique aspects to provide qualitative or quantitative data about the unknown chemicals present, not all detectors provide consistent, accurate, and reliable results. Includedmore » here, in a consumer-report-style format, we provide “boots on the ground” information directly from first responders about how well colorimetric chemical detection methods meet their needs in the field and how they procure these methods.« less
Russell, Steven M; Doménech-Sánchez, Antonio; de la Rica, Roberto
2017-06-23
Colorimetric tests are becoming increasingly popular in point-of-need analyses due to the possibility of detecting the signal with the naked eye, which eliminates the utilization of bulky and costly instruments only available in laboratories. However, colorimetric tests may be interpreted incorrectly by nonspecialists due to disparities in color perception or a lack of training. Here we solve this issue with a method that not only detects colorimetric signals but also interprets them so that the test outcome is understandable for anyone. It consists of an augmented reality (AR) app that uses a camera to detect the colored signals generated by a nanoparticle-based immunoassay, and that yields a warning symbol or message when the concentration of analyte is higher than a certain threshold. The proposed method detected the model analyte mouse IgG with a limit of detection of 0.3 μg mL -1 , which was comparable to the limit of detection afforded by classical densitometry performed with a nonportable device. When adapted to the detection of E. coli, the app always yielded a "hazard" warning symbol when the concentration of E. coli in the sample was above the infective dose (10 6 cfu mL -1 or higher). The proposed method could help nonspecialists make a decision about drinking from a potentially contaminated water source by yielding an unambiguous message that is easily understood by anyone. The widespread availability of smartphones along with the inexpensive paper test that requires no enzymes to generate the signal makes the proposed assay promising for analyses in remote locations and developing countries.
Zhang, Zhiyang; Wang, Han; Chen, Zhaopeng; Wang, Xiaoyan; Choo, Jaebum; Chen, Lingxin
2018-08-30
Plasmonic colorimetric sensors have emerged as a powerful tool in chemical and biological sensing applications due to the localized surface plasmon resonance (LSPR) extinction in the visible range. Among the plasmonic sensors, the most famous sensing mode is the "aggregation" plasmonic colorimetric sensor which is based on plasmon coupling due to nanoparticle aggregation. Herein, this review focuses on the newly-developing plasmonic colorimetric sensing mode - the etching or the growth of metal nanoparticles induces plasmon changes, namely, "non-aggregation" plasmonic colorimetric sensor. This type of sensors has attracted increasing interest because of their exciting properties of high sensitivity, multi-color changes, and applicability to make a test strip. Of particular interest, the test strip by immobilization of nanoparticles on the substrate can avoid the influence of nanoparticle auto-aggregation and increase the simplicity in storage and use. Although there are many excellent reviews available that describe the advance of plasmonic sensors, limited attention has been paid to the plasmonic colorimetric sensors based on etching or growth of metal nanoparticles. This review highlights recent progress on strategies and application of "non-aggregation" plasmonic colorimetric sensors. We also provide some personal insights into current challenges associated with "non-aggregation" plasmonic colorimetric sensors and propose future research directions. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kang, Fei; Hou, Xiangshu; Xu, Kun
2015-10-01
Glucose is a key energy substance in diverse biology and closely related to the life activities of the organism. To develop a simple and sensitive method for glucose detection is extremely urgent but still remains a key challenge. Herein, we report a colorimetric glucose sensor in a homogeneous system based on DNA-embedded core-shell Au@Ag nanoparticles. In this assay, a glucose substrate was first catalytically oxidized by glucose oxidase to produce H2O2 which would further oxidize and gradually etch the outer silver shell of Au@Ag nanoparticles. Afterwards, the solution color changed from yellow to red and the surface plasmon resonance (SPR) band of Au@Ag nanoparticles declined and red-shifted from 430 to 516 nm. Compared with previous silver-based glucose colorimetric detection strategies, the distinctive SPR band change is superior to the color variation, which is critical to the high sensitivity of this assay. Benefiting from the outstanding optical property, robust stability and well-dispersion of the core-shell Au@AgNPs hybrid, this colorimetric assay obtained a detection limit of glucose as low as 10 nM, which is at least a 10-fold improvement over other AgNPs-based procedures. Moreover, this optical biosensor was successfully employed to the determination of glucose in fetal bovine serum.
Accuracy of Blood Loss Measurement during Cesarean Delivery.
Doctorvaladan, Sahar V; Jelks, Andrea T; Hsieh, Eric W; Thurer, Robert L; Zakowski, Mark I; Lagrew, David C
2017-04-01
Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland-Altman method. Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R 2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R 2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R 2 = 0.304). Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes.
Accuracy of Blood Loss Measurement during Cesarean Delivery
Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.
2017-01-01
Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland–Altman method. Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R2 = 0.304). Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes. PMID:28497007
NASA Astrophysics Data System (ADS)
Vallu, Rama Krishna; Velugula, Krishna; Doshi, Sejal; Chinta, Jugun Prakash
2018-01-01
Colorimetric and fluorimetric detection of toxic metal ions such as Hg2 + and Cr3 + has gained tremendous popularity over the conventional methods due to their operational simplicity, high selectivity, and speediness. Although numerous colorimetric and fluorescent receptors for Hg2 + or Cr3 + were reported in the literature, boronic acid-based receptors for these metal ions are rather scarce in the literature. Hence, in the present study dual function boronic acid conjugated rhodamine derivatives were developed, and their toxic metal ion detection abilities were studied by absorption, emission and visual detection methods. Absorption and emission spectral studies revealed that these derivatives displayed selectivity towards Hg2 +, Cr3 + and Fe3 + among the other metal ions studied by forming new absorption band. Both the derivatives exhibited colorimetric response towards Hg2 + and Cr3 + by the change in color of the solution to pink and reddish pink with Fe3 +. The detailed mechanism involved in the detection of Hg2 + was deduced by 1H NMR and ESI-MS studies. Further, these derivatives were used for fluorescence imaging of Hg2 + and Cr3 + in S. aureus bacterial cells. Thus the present manuscript demonstrated the use of boronic acid conjugated rhodamine derivatives as a dual function (colorimetric and fluorescent) probes and as imaging agents for Hg2 + and Cr3 +, which are known for their toxic influence on bacterial cells.
Convert a low-cost sensor to a colorimeter using an improved regression method
NASA Astrophysics Data System (ADS)
Wu, Yifeng
2008-01-01
Closed loop color calibration is a process to maintain consistent color reproduction for color printers. To perform closed loop color calibration, a pre-designed color target should be printed, and automatically measured by a color measuring instrument. A low cost sensor has been embedded to the printer to perform the color measurement. A series of sensor calibration and color conversion methods have been developed. The purpose is to get accurate colorimetric measurement from the data measured by the low cost sensor. In order to get high accuracy colorimetric measurement, we need carefully calibrate the sensor, and minimize all possible errors during the color conversion. After comparing several classical color conversion methods, a regression based color conversion method has been selected. The regression is a powerful method to estimate the color conversion functions. But the main difficulty to use this method is to find an appropriate function to describe the relationship between the input and the output data. In this paper, we propose to use 1D pre-linearization tables to improve the linearity between the input sensor measuring data and the output colorimetric data. Using this method, we can increase the accuracy of the regression method, so as to improve the accuracy of the color conversion.
Improving colorimetric assays through protein enzyme-assisted gold nanoparticle amplification.
Xie, Xiaoji; Xu, Wei; Liu, Xiaogang
2012-09-18
The discovery of the DNA-mediated assembly of gold nanoparticles was a great moment in the history of science; this understanding and chemical control enabled the rational design of functional nanomaterials as novel probes in biodetection. In contrast with conventional probes such as organic dyes, gold nanoparticles exhibit high photostability and unique size-dependent optical properties. Because of their high extinction coefficients and strong distance dependent optical properties, these nanoparticles have emerged over the past decade as a promising platform for rapid, highly sensitive colorimetric assays that allow for the visual detection of low concentrations of metal ions, small molecules, and biomacromolecules. These discoveries have deepened our knowledge of biological phenomena and facilitated the development of many new diagnostic and therapeutic tools. Despite these many advances and continued research efforts, current nanoparticle-based colorimetric detection systems still suffer from several drawbacks, such as limited sensitivity and selectivity. This Account describes the recent development of colorimetric assays based on protein enzyme-assisted gold nanoparticle amplification. The benefits of such detection systems include significantly improved detection sensitivity and selectivity. First, we discuss the general design of enzyme-modified nanoparticle systems in colorimetric assays. We show that a quantitative understanding of the unique properties of different enzymes is paramount for effective biological assays. We then examine the assays for nucleic acid detection based on different types of enzymes, including endonucleases, ligases, and polymerases. For each of these assays, we identify the underlying principles that contribute to the enhanced detection capability of nanoparticle systems and illustrate them with selected examples. Furthermore, we demonstrate that the combination of gold nanoparticles and specific enzymes can probe enzyme dynamics and function with high specificity, offering substantial advantages in both sensitivity and specificity over conventional detection methods. The screening of nuclease, methyltransferase, protease, and kinase activities can be colorimetrically performed in a straightforward manner. Finally, we discuss examples of colorimetric assays for metal ions and small molecules that constitute important advances toward visual monitoring of enzyme catalytic functions and gene expression. Although these enzyme-assisted assay methods hold great promise for myriad applications in biomedicine and bioimaging, the application of the described techniques in vivo faces formidable challenges. In addition, researchers do not fully understand the interactions of gold nanoparticles with enzyme molecules. This understanding will require the development of new techniques to probe enzyme substrate dynamics at the particle interface with higher spatial resolution and chemical specificity.
NASA Astrophysics Data System (ADS)
Kärhä, Petri; Vaskuri, Anna; Mäntynen, Henrik; Mikkonen, Nikke; Ikonen, Erkki
2017-08-01
Spectral irradiance data are often used to calculate colorimetric properties, such as color coordinates and color temperatures of light sources by integration. The spectral data may contain unknown correlations that should be accounted for in the uncertainty estimation. We propose a new method for estimating uncertainties in such cases. The method goes through all possible scenarios of deviations using Monte Carlo analysis. Varying spectral error functions are produced by combining spectral base functions, and the distorted spectra are used to calculate the colorimetric quantities. Standard deviations of the colorimetric quantities at different scenarios give uncertainties assuming no correlations, uncertainties assuming full correlation, and uncertainties for an unfavorable case of unknown correlations, which turn out to be a significant source of uncertainty. With 1% standard uncertainty in spectral irradiance, the expanded uncertainty of the correlated color temperature of a source corresponding to the CIE Standard Illuminant A may reach as high as 37.2 K in unfavorable conditions, when calculations assuming full correlation give zero uncertainty, and calculations assuming no correlations yield the expanded uncertainties of 5.6 K and 12.1 K, with wavelength steps of 1 nm and 5 nm used in spectral integrations, respectively. We also show that there is an absolute limit of 60.2 K in the error of the correlated color temperature for Standard Illuminant A when assuming 1% standard uncertainty in the spectral irradiance. A comparison of our uncorrelated uncertainties with those obtained using analytical methods by other research groups shows good agreement. We re-estimated the uncertainties for the colorimetric properties of our 1 kW photometric standard lamps using the new method. The revised uncertainty of color temperature is a factor of 2.5 higher than the uncertainty assuming no correlations.
NASA Astrophysics Data System (ADS)
Wang, Weiguo; Zou, Yake; Yan, Jinwu; Liu, Jing; Chen, Huixiong; Li, Shan; Zhang, Lei
2018-03-01
In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG antibody (β-submit, mAb1) were co-immobilized onto the Au@Pt NP surface to improve catalytic efficiency and specificity, which formed a dual functionalized Au@Pt-HRP probe with the mean size of 42.8 nm (D50). The colorimetric immunoassay was developed for the hCG detection, and the Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4-12.8 IU L- 1 with a low limit of detection (LOD) of 0.1 IU L- 1 compared with the LODs of 0.8 IU L- 1 for BA-ELISA and of 2.0 IU L- 1 for Au@Pt, which indicated that the Au@Pt-HRP probe possessed higher catalytic efficiency with 2.8-fold increase over Au@Pt and 33.8-fold increase over HRP. Also, the Au@Pt-HRP probe exhibited good precision and reproducibility, high specificity and acceptable accuracy with CV being less than 15%. The dual functionalized Au@Pt-HRP probe as a type of signal amplified method was firstly applied in the colorimetric immunoassay for the hCG detection.
Mondal, Bhairab; N, Bhavanashri; Ramlal, Shylaja; Kingston, Joseph
2018-02-14
In the present study, a colorimetric DNAzymes biosensor strategy was devised in combination with immunomagnetic separation for rapid and easy detection of enterotoxin B harboring Staphylococcus aureus from food and clinical samples. The method employs immunocapture of S. aureus and amplification of seb gene by DNAzyme complementary sequence integrated forward primer and with specific reverse primer. The DNAzyme sequence integrated dsDNA PCR products when treated with hemin and TMB (3,3',5,5'-tetramethylbenzidine) in the presence of H 2 O 2 produce colorimetric signal. A linear relationship of optical signal with the initial template of seb was obtained which could be monitored by visually or spectrophotrometrically for qualitative and quantitative detection. The limit of detection for the assay was approximately 10 2 CFU/mL of seb gene harboring target. This method is convenient compared to gel based and ELISA systems. Further, spiking studies and analysis on natural samples emphasized the robustness and applicability of developed method. Altogether, the established assay could be a reliable alternative, low-cost, viable detection tool for the routine investigation of seb from food and clinical sources.
NASA Astrophysics Data System (ADS)
Tavallali, Hossein; Deilamy-Rad, Gohar; Moaddeli, Ali; Asghari, Khadijeh
2017-08-01
A new selective probe based on copper complex of Indigo Carmine (IC-Cu2) for colorimetric, naked-eye, and fluorimetric recognition of mono hydrogen phosphate (MHP) ion in H2O/DMSO (4:1 v/v, 1.0 mmol L- 1 HEPES buffer solution pH 7.5) was developed. Detection limit of HPO42 - determination, achieved by fluorimetric and 3lorimetric method, are 0.071 and 1.46 μmol L- 1, respectively. Potential, therefore is clearly available in IC-Cu2 complex to detect HPO42 - in micromolar range via dual visible color change and fluorescence response. Present method shows high selectivity toward HPO42 - over other phosphate species and other anions and was successfully utilized for analysis of P2O5 content of a fertilizer sample. The results obtained by proposed chemosensor presented good agreement with those obtained the colorimetric reference method. INHIBIT and IMPLICATION logic gates operating at molecular level have been achieved using Cu2 + and HPO42 - as chemical inputs and UV-Vis absorbance signal as output.
NASA Astrophysics Data System (ADS)
Powless, Amy J.; Conley, Roxanna J.; Freeman, Karan A.; Muldoon, Timothy J.
2017-03-01
There exists a broad range of techniques that can be used to classify and count white blood cells in a point-of-care (POC) three-part leukocyte differential test. Improvements in lenses, light sources, and cameras for image-based POC systems have renewed interest in acridine orange (AO) as a contrast agent, whereby subpopulations of leukocytes can be differentiated by colorimetric analysis of AO fluorescence emission. We evaluated the effect on test accuracy using different AO staining and postprocessing methods in the context of an image-based POC colorimetric cell classification scheme. Thirty blood specimens were measured for percent cell counts using our POC system and a conventional hematology analyzer for comparison. Controlling the AO concentration used during whole-blood staining, the incubation time with AO, and the colorimetric ratios among the three population of leukocytes yielded a percent deviation of 0.706%, -1.534%, and -0.645% for the lymphocytes, monocytes, and granulocytes, respectively. Overall, we demonstrated that a redshift in AO fluorescence was observed at elevated AO concentrations, which lead to reproducible inaccuracy of cell counts. This study demonstrates there is a need for a strict control of the AO staining and postprocessing methods to improve test accuracy in these POC systems.
NASA Astrophysics Data System (ADS)
Cao, Qian; Wan, Xiaoxia; Li, Junfeng; Liu, Qiang; Liang, Jingxing; Li, Chan
2016-10-01
This paper proposed two weight functions based on principal component analysis (PCA) to reserve more colorimetric information in spectral data compression process. One weight function consisted of the CIE XYZ color-matching functions representing the characteristic of the human visual system, while another was made up of the CIE XYZ color-matching functions of human visual system and relative spectral power distribution of the CIE standard illuminant D65. The improvement obtained from the proposed two methods were tested to compress and reconstruct the reflectance spectra of 1600 glossy Munsell color chips and 1950 Natural Color System color chips as well as six multispectral images. The performance was evaluated by the mean values of color difference under the CIE 1931 standard colorimetric observer and the CIE standard illuminant D65 and A. The mean values of root mean square errors between the original and reconstructed spectra were also calculated. The experimental results show that the proposed two methods significantly outperform the standard PCA and another two weighted PCA in the aspects of colorimetric reconstruction accuracy with very slight degradation in spectral reconstruction accuracy. In addition, weight functions with the CIE standard illuminant D65 can improve the colorimetric reconstruction accuracy compared to weight functions without the CIE standard illuminant D65.
Ramezani, Mohammad; Abnous, Khalil; Taghdisi, Seyed Mohammad
2017-01-01
Detection and quantitation of antibiotic residues in blood serum and foodstuffs are in great demand. We have developed aptasensors for detection of streptomycin using electrochemical and optical methods. In the first method, an electrochemical aptasensor was developed for sensitive and selective detection of streptomycin, based on combination of exonuclease I (Exo I), complementary strand of aptamer (CS), arch shaped structure of aptamer (Apt)-CS conjugate, and gold electrode. The designed electrochemical aptasensor exhibited high selectivity toward streptomycin with a limit of detection (LOD) as low as 11.4 nM. Moreover, the developed electrochemical aptasensor was successfully used to detect streptomycin in milk and serum with LODs of 14.1 and 15.3 nM, respectively. In the second method, fluorescence quenching and colorimetric aptasensors were designed for detection of streptomycin based on aqueous gold nanoparticles (AuNPs) and double-stranded DNA (dsDNA). In the absence of streptomycin, aptamer/FAM-labeled complementary strand dsDNA is stable, resulting in the aggregation of AuNPs by salt bridge and an obvious color change from red to blue and strong emission of fluorescence. The colorimetric and fluorescence quenching aptasensors showed excellent selectivity toward streptomycin with limit of detections as low as 73.1 and 47.6 nM, respectively. The presented aptasensors were successfully used to detect streptomycin in milk and serum. For serum, LODs were determined to be 58.2 and 102.4 nM for fluorescence quenching and colorimetric aptasensors, respectively. For milk, LODs were calculated to be 56.2 and 108.7 nM for fluorescence quenching and colorimetric aptasensors, respectively.
Comparison of macro-gravimetric and micro-colorimetric lipid determination methods.
Inouye, Laura S; Lotufo, Guiherme R
2006-10-15
In order to validate a method for lipid analysis of small tissue samples, the standard macro-gravimetric method of Bligh-Dyer (1959) [E.G. Bligh, W.J. Dyer, Can. J. Biochem. Physiol. 37 (1959) 911] and a modification of the micro-colorimetric assay developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1 (1985) 302] were compared. No significant differences were observed for wet tissues of two species of fish. However, limited analysis of wet tissue of the amphipod, Leptocheirusplumulosus, indicated that the Bligh-Dyer gravimetric method generated higher lipid values, most likely due to the inclusion of non-lipid materials. Additionally, significant differences between the methods were observed with dry tissues, with the micro-colorimetric method consistently reporting calculated lipid values greater than as reported by the gravimetric method. This was most likely due to poor extraction of dry tissue in the standard Bligh-Dyer method, as no significant differences were found when analyzing a single composite extract. The data presented supports the conclusion that the micro-colorimetric method described in this paper is accurate, rapid, and minimizes time and solvent use.
NASA Astrophysics Data System (ADS)
Qi, Yingying; Li, Li; Li, Baoxin
2009-09-01
A simple and sensitive label-free colorimetric detection of telomere DNA has been developed. It was based on the color change of gold nanoparticles (AuNPs) due to DNA hybridization. UV-vis spectra and transmission electron microscopy (TEM) were used to investigate the change of AuNPs. Under the optimized conditions, the linear range for determination of telomere DNA was 5.7 × 10 -13 to 4.5 × 10 -6 mol/L. The detection limit (3 σ) of this method has decreased to pico-molar level.
Infrared and colorimetric characterization of discolored kiln-dried hard maple lumber
Benjamin E. Dawson-Andoh; Michael Wiemann; Laurent Matuana; John Baumgras
2004-01-01
Discoloration of hard maple lumber commonly occurs during kiln-drying. In this study, discolored andnondiscolored kiln-dried hard maple lumber boards were characterized using a colorimetric method and Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR). Colorimetric measurements (L*, a*, b*) were found to be in good agreement with visual...
NASA Astrophysics Data System (ADS)
Alizadeh, A.; Khodaei, M. M.; Karami, Ch; Workentin, M. S.; Shamsipur, M.; Sadeghi, M.
2010-08-01
A gold nanoparticle (AuNPs)-based simple and fast colorimetric sensor for selective detecting of Pb(II) in aqueous solution has been developed. Monodisperse AuNPs (approx. 2.0 nm diameter) has been prepared facilely and further modified with an alkanethiol-bearing monoazacrown ether terminus. These AuNPs are shown to selectively sense Pb2 + through color change, which is visually discernible by an appearance of the surface plasmon band (SPB) at 520 nm. The recognition mechanism is attributed to the unique structure of the monoazacrown ether attached to AuNPs and metal sandwich coordination between two azacrown ether moieties that are attached to separate nanoparticles. This inter-particle cross-linking results in an aggregation and apparent color change from brown to purple. Additionally, TEM experiments support the optical absorption data proving the aggregation between azacrown ether-capped gold nanoparticles. This AuNP-based colorimetric assay is a facile and robust method and allows fast detection of Pb2 + at ambient temperatures. More importantly, the developed technique does not utilize enzymatic reactions, light-sensitive dye molecules, lengthy protocols or sophisticated instrumentation.
Sergeyeva, T A; Gorbach, L A; Piletska, E V; Piletsky, S A; Brovko, O O; Honcharova, L A; Lutsyk, O D; Sergeeva, L M; Zinchenko, O A; El'skaya, A V
2013-04-03
An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N'-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25-2.5mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.
da Silva, Gabriela O; de Araujo, William R; Paixão, Thiago R L C
2018-01-01
An office paper-based colorimetric device is proposed as a portable, rapid, and low-cost sensor for forensic applications aiming to detect phenacetin used as adulterant in illicit seized materials such as cocaine. The proposed method uses white office paper as the substrate and wax printing technology to fabricate the detection zones. Based on the optimum conditions, a linear analytical curve was obtained for phenacetin concentrations ranging from 0 to 64.52µgmL ‒1 , and the straight line was in accordance with the following equation: (Magenta percentage color) = 1.19 + 0.458 (C Phe /µgmL ‒1 ), R 2 = 0.990. The limit of detection was calculated as 3.5µgmL ‒1 (3σ/slope). The accuracy of the proposed method was evaluated using real seized cocaine samples and the spike-recovery procedure. Copyright © 2017 Elsevier B.V. All rights reserved.
A MODIFIED LOW COST COLOURIMETRIC METHOD FOR PARACETAMOL (ACETAMINOPHEN) MEASUREMENT IN PLASMA
Shihana, Fathima; Dissanayake, Dhammika Menike; Dargan, Paul Ivor; Dawson, Andrew Hamilton
2011-01-01
Background Despite a significant increase in the number of patients with paracetamol poisoning in the developing world, plasma paracetamol assays are not widely available. The purpose of this study was to assess a low cost modified colorimetric paracetamol assay that has the potential to be performed in small laboratories with restricted resources. Methods The paracetamol assay used in this study was based on the Glynn and Kendal colorimetric method with a few modifications in order to decrease the production of nitrous gas and thereby reduce infrastructure costs. Preliminary validation studies were performed using spiked aqueous samples with known concentrations of paracetamol. Subsequently, the results from the colorimetric method for 114 stored clinical samples from patients with paracetamol poisoning were compared with those from the current gold-standard high-performance liquid chromatography (HPLC) method. A prospective survey, assessing the clinical use of the paracetamol assay, was performed on all patients with paracetamol poisoning attending the Peradeniya General Hospital, Sri Lanka over a ten-month period. Results The recovery study showed an excellent correlation (r2 >0.998) for paracetamol concentrations from 25- 400 mg/l. The final yellow colour was stable for at least 10 minutes at room temperature. There was also excellent correlation with the HPLC method (r2=0.9758). In the clinical cohort study, use of the antidote N-acetylcysteine was avoided in over a third of patients who had a plasma paracetamol concentration measured. The cost of consumables used per assay was $0.50 (US). Conclusions This colorimetric paracetamol assay is reliable and accurate and can be performed rapidly, easily and economically. Use of this assay in resource poor clinical settings has the potential to have a significant clinical and economic impact on the management of paracetamol poisoning. PMID:20095813
The Disassembly of a Core-Satellite Nanoassembled Substrate for Colorimetric Biomolecular Detection
Waldeisen, John R.; Wang, Tim; Ross, Benjamin M.; Lee, Luke P.
2012-01-01
The disassembly of a core-satellite nanostructured substrate is presented as a colorimetric biosensor observable under dark field illumination. The fabrication method described herein utilizes thiol-mediated adsorption and streptavidin-biotin binding to self-assemble core-satellite nanostructures with a sacrificial linking peptide. Biosensing functionality is demonstrated with the protease trypsin and the optical properties of the nanoassemblies are characterized. A figure of merit is presented to determine the optimal core and satellite size for visual detection. Nanoassemblies with 50 nm cores and 30 nm or 50 nm satellites are superior as these structures achieve an orange to green color shift greater than 70 nm that is easily discernible by naked eye. This colorimetric substrate may prove to be a favorable alternative to liquid-based colloidal sensors and a useful visual readout mechanism for microfluidic diagnostic assays. PMID:21667984
NASA Astrophysics Data System (ADS)
Abubaker, Mariam; Ngah, Che Wan Zanariah Che Wan; Ahmad, Musa; Kuswandi, Bambang
2018-06-01
A sensitive and selective colorimetric method has been developed for detection of Al3+ ion using 4-benzoyl pyrazolone-functionalized gold nanoparticles (BMPBP-AuNPs) as novel colorimetric probes. The BMPBP-AuNPs were characterized by UV-visible spectrometry and transmission electron microscopy (TEM). It was found that the addition of the Al3+ ions led to a rapid aggregation of the BMPBP-AuNPs, which changed the color of the mixture from red to blue. Furthermore, there was a shift in the characteristic surface plasmon resonance (SPR) peak from 524 to 650 nm of BMPBP-AuNPs, which confirmed that a good linear relation (R2 = 0.9935) was present between the absorption ratio of 524 and 650 nm. Also, the assay detected the Al3+ ion concentrations in the linear range 0-12 ppm with the detection limit is 0.05 ppm. Finally, the synthesized BMPBP-AuNPs were successfully used as a colorimetric sensor for the selective and sensitive detection of the Al3+ ions in water samples.
NASA Astrophysics Data System (ADS)
Dittrich, Paul-Gerald; Grunert, Fred; Ehehalt, Jörg; Hofmann, Dietrich
2015-03-01
Aim of the paper is to show that the colorimetric characterization of optically clear colored liquids can be performed with different measurement methods and their application specific multichannel spectral sensors. The possible measurement methods are differentiated by the applied types of multichannel spectral sensors and therefore by their spectral resolution, measurement speed, measurement accuracy and measurement costs. The paper describes how different types of multichannel spectral sensors are calibrated with different types of calibration methods and how the measurement values can be used for further colorimetric calculations. The different measurement methods and the different application specific calibration methods will be explained methodically and theoretically. The paper proofs that and how different multichannel spectral sensor modules with different calibration methods can be applied with smartpads for the calculation of measurement results both in laboratory and in field. A given practical example is the application of different multichannel spectral sensors for the colorimetric characterization of petroleum oils and fuels and their colorimetric characterization by the Saybolt color scale.
New method for the direct determination of dissolved Fe(III) concentration in acid mine waters
To, T.B.; Nordstrom, D. Kirk; Cunningham, K.M.; Ball, J.W.; McCleskey, R. Blaine
1999-01-01
A new method for direct determination of dissolved Fe(III) in acid mine water has been developed. In most present methods, Fe(III) is determined by computing the difference between total dissolved Fe and dissolved Fe(II). For acid mine waters, frequently Fe(II) >> Fe(III); thus, accuracy and precision are considerably improved by determining Fe(III) concentration directly. The new method utilizes two selective ligands to stabilize Fe(III) and Fe(II), thereby preventing changes in Fe reduction-oxidation distribution. Complexed Fe(II) is cleanly removed using a silica-based, reversed-phase adsorbent, yielding excellent isolation of the Fe(III) complex. Iron(III) concentration is measured colorimetrically or by graphite furnace atomic absorption spectrometry (GFAAS). The method requires inexpensive commercial reagents and simple procedures that can be used in the field. Calcium(II), Ni(II), Pb(II), AI(III), Zn(II), and Cd(II) cause insignificant colorimetric interferences for most acid mine waters. Waters containing >20 mg of Cu/L could cause a colorimetric interference and should be measured by GFAAS. Cobalt(II) and Cr(III) interfere if their molar ratios to Fe(III) exceed 24 and 5, respectively. Iron(II) interferes when its concentration exceeds the capacity of the complexing ligand (14 mg/L). Because of the GFAAS elemental specificity, only Fe(II) is a potential interferent in the GFAAS technique. The method detection limit is 2 ??g/L (40 nM) using GFAAS and 20 ??g/L (0.4 ??M) by colorimetry.A new method for direct determination of dissolved Fe(III) in acid mine water has been developed. In most present methods, Fe(III) is determined by computing the difference between total dissolved Fe and dissolved Fe(II). For acid mine waters, frequently Fe(II)???Fe(III); thus, accuracy and precision are considerably improved by determining Fe(III) concentration directly. The new method utilizes two selective ligands to stabilize Fe(III) and Fe(II), thereby preventing changes in Fe reduction-oxidation distribution. Complexed Fe(II) is cleanly removed using a silica-based, reversed-phase adsorbent, yielding excellent isolation of the Fe(III) complex. Iron(III) concentration is measured colorimetrically or by graphite furnace atomic absorption spectrometry (GFAAS). The method requires inexpensive commercial reagents and simple procedures that can be used in the field. Calcium(II), Ni(II), Pb(II), Al(III), Zn(II), and Cd(II) cause insignificant colorimetric interferences for most acid mine waters. Waters containing >20 mg of Cu/L could cause a colorimetric interference and should be measured by GFAAS. Cobalt(II) and Cr(III) interfere if their molar ratios to Fe(III) exceed 24 and 5, respectively. Iron(II) interferes when its concentration exceeds the capacity of the complexing ligand (14 mg/L). Because of the GFAAS elemental specificity, only Fe(II) is a potential interferent in the GFAAS technique. The method detection limit is 2/??g/L (40 nM) using GFAAS and 20 ??g/L (0.4 ??M) by colorimetry.
Colorimetric sensor for cysteine in human urine based on novel gold nanoparticles.
Zhang, Yan; Jiang, Jingjing; Li, Min; Gao, Pengfei; Zhou, Ying; Zhang, Guomei; Shuang, Shaomin; Dong, Chuan
2016-12-01
Herein, a novel, high sensitive, and specific colorimetric sensor for cysteine (Cys) based on pectinase protected gold nanoparticles (P@AuNPs) has been demonstrated for the first time. The P@AuNPs were synthesized by "MW-assisted heat method" and were characterized by UV-vis, TEM, FT-IR and zeta potential techniques. Cys could cause the aggregation of P@AuNPs due to formation of the strong covalent Au-S bond and electrostatic binding. As the Cys concentration increased, the color of the solutions gradually changed from wine-red to blue as well as the large absorption band shifted from 523 to 650nm upon P@AuNPs aggregation. In addition, various experimental parameters such as pH, the amount of P@AuNPs and incubation time were investigated for the optimum sensing conditions. The concentration of Cys could be determined by monitoring with the naked eye or a UV-vis spectrometer. The proposed colorimetric sensor showed an extreme selectivity toward the determination of Cys in the presence of 20-fold all other different interferents. Under optimum conditions, this method exhibited two good linear ranges from 4.85×10 -9 to 3.02×10 -4 M (R 2 =0.996) and 3.25×10 -3 to 1.03×10 -2 M (R 2 =0.999), with a low detection limit of 4.6×10 -9 M. Moreover, this colorimetric sensor was successfully applied to the detection of Cys in human urine samples, demonstrating its great value for practical application in biological systems. Copyright © 2016 Elsevier B.V. All rights reserved.
Silva, Thalita G; de Araujo, William R; Muñoz, Rodrigo A A; Richter, Eduardo M; Santana, Mário H P; Coltro, Wendell K T; Paixão, Thiago R L C
2016-05-17
We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.
A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution
NASA Astrophysics Data System (ADS)
Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li
2016-03-01
A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.
Selective Distance-Based K+ Quantification on Paper-Based Microfluidics.
Gerold, Chase T; Bakker, Eric; Henry, Charles S
2018-04-03
In this study, paper-based microfluidic devices (μPADs) capable of K + quantification in aqueous samples, as well as in human serum, using both colorimetric and distance-based methods are described. A lipophilic phase containing potassium ionophore I (valinomycin) was utilized to achieve highly selective quantification of K + in the presence of Na + , Li + , and Mg 2+ ions. Successful addition of a suspended lipophilic phase to a wax printed paper-based device is described and offers a solution to current approaches that rely on organic solvents, which damage wax barriers. The approach provides an avenue for future alkali/alkaline quantification utilizing μPADs. Colorimetric spot tests allowed for K + quantification from 0.1-5.0 mM using only 3.00 μL of sample solution. Selective distance-based quantification required small sample volumes (6.00 μL) and gave responses sensitive enough to distinguish between 1.0 and 2.5 mM of sample K + . μPADs using distance-based methods were also capable of differentiating between 4.3 and 6.9 mM K + in human serum samples. Distance-based methods required no digital analysis, electronic hardware, or pumps; any steps required for quantification could be carried out using the naked eye.
Li, Dan; Duan, Huazhen; Ma, Yadan; Deng, Wei
2018-05-01
This study demonstrates a novel strategy for colorimetric/surface-enhanced Raman scattering (SERS) dual-mode sensing of sulfur dioxide (SO 2 ) by coupling headspace sampling (HS) with paper-based analytical device (PAD). The smart and multifunctional PAD is fabricated with a vacuum filtration method in which 4-mercaptopyridine (Mpy)-modified gold nanorods (GNRs)-reduced graphene oxide (rGO) hybrids (rGO/MPy-GNRs), anhydrous methanol, and starch-iodine complex are immobilized into cellulose-based filter papers. The resultant PAD exhibits a deep-blue color with a strong absorption peak at 600 nm due to the formation of an intermolecular charge-transfer complex between starch and iodine. However, the addition of SO 2 induces the Karl Fischer reaction, resulting in the decrease of color and increase of SERS signals. Therefore, the PAD can be used not only as a naked-eye indicator of SO 2 changed from blue to colorless but also as a highly sensitive SERS substrates because of the SO 2 -triggered conversion of Mpy to pyridine methyl sulfate on the GNRs. A distinguishable change in the color was observed at a SO 2 concentration of 5 μM by the naked eye, and a detection limit as low as 1.45 μM was obtained by virtue of UV-vis spectroscopy. The PAD-based SERS method is effective over a wide range of concentrations (1 μM to 2000 μM) for SO 2 , and the detection limit for SO 2 is found to be 1 μM. The HS-PAD based colorimetric/SERS method is applied for the determination of SO 2 in wine, and the detection results match well with those obtained from the traditional Monier-Williams method. This study not only offers a new method for on-site monitoring of SO 2 but also provides a new strategy for designing of paper-based sensing platform for a wide range of field-test applications.
Li, Z; Chang, S; Lin, L; Li, Y; An, Q
2011-08-01
1-Aminocyclopropane-1-carboxylate (ACC) deaminase activity is an efficient marker for bacteria to promote plant growth by lowering ethylene levels in plants. We aim to develop a method for rapidly screening bacteria containing ACC deaminase, based on a colorimetric ninhydrin assay of ACC. A reliable colorimetric ninhydrin assay was developed to quantify ACC using heat-resistant polypropylene chimney-top 96-well PCR plates, having the wells evenly heated in boiling water, preventing accidental contamination from boiling water and limiting evaporation. With this method to measure bacterial consumption of ACC, 44 ACC-utilizing bacterial isolates were rapidly screened out from 311 bacterial isolates that were able to grow on minimal media containing ACC as the sole nitrogen source. The 44 ACC-utilizing bacterial isolates showed ACC deaminase activities and belonged to the genus Burkholderia, Pseudomonas or Herbaspirillum. Determination of bacterial ACC consumption by the PCR-plate ninhydrin-ACC assay is a rapid and efficient method for screening bacteria containing ACC deaminase from a large number of bacterial isolates. The PCR-plate ninhydrin-ACC assay extends the utility of the ninhydrin reaction and enables a rapid screening of bacteria containing ACC deaminase from large numbers of bacterial isolates. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Two common laboratory extraction techniques were evaluated for routine use with the micro-colorimetric lipid determination method developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1(1985) 302] and recently validated for small samples by Inouye and Lotufo ...
[Colorimetric characterization of LCD based on wavelength partition spectral model].
Liu, Hao-Xue; Cui, Gui-Hua; Huang, Min; Wu, Bing; Xu, Yan-Fang; Luo, Ming
2013-10-01
To establish a colorimetrical characterization model of LCDs, an experiment with EIZO CG19, IBM 19, DELL 19 and HP 19 LCDs was designed and carried out to test the interaction between RGB channels, and then to test the spectral additive property of LCDs. The RGB digital values of single channel and two channels were given and the corresponding tristimulus values were measured, then a chart was plotted and calculations were made to test the independency of RGB channels. The results showed that the interaction between channels was reasonably weak and spectral additivity property was held well. We also found that the relations between radiations and digital values at different wavelengths varied, that is, they were the functions of wavelength. A new calculation method based on piecewise spectral model, in which the relation between radiations and digital values was fitted by a cubic polynomial in each piece of wavelength with measured spectral radiation curves, was proposed and tested. The spectral radiation curves of RGB primaries with any digital values can be found out with only a few measurements and fitted cubic polynomial in this way and then any displayed color can be turned out by the spectral additivity property of primaries at given digital values. The algorithm of this method was discussed in detail in this paper. The computations showed that the proposed method was simple and the number of measurements needed was reduced greatly while keeping a very high computation precision. This method can be used as a colorimetrical characterization model.
Mondal, Bhairab; Ramlal, Shylaja; Lavu, Padma S.; N, Bhavanashri; Kingston, Joseph
2018-01-01
A simple, sensitive and selective colorimetric biosensor for the detection of Staphylococcal enterotoxin B (SEB) was developed using SEB-binding aptamer (SEB2) as recognition element and unmodified gold nanoparticles (AuNPs) as colorimetric probes. The assay is based on color change from red to purple due to conformational change of aptamer in the presence of SEB, and the phenomenon of salt-induced AuNPs aggregation which could be monitored by naked eye or UV–vis spectrometer. Results showed that the AuNPs can effectively differentiate the SEB induced conformational change of the aptamer in the presence of a given high salt concentration. A linear response in the range of 50 μg/mL to 0.5 ng/mL of SEB concentration was obtained. The assay was highly specific to SEB as compared to other related toxins. The limit of detection (LOD) of SEB achieved within few minutes was 50 ng/mL visually and spectrometric method improved it to 0.5 ng/mL. Robustness of the assay was tested in artificially spiked milk samples and cross-checked using in house developed sandwich ELISA (IgY as capturing and SEB specific monoclonal as revealing antibody) and PCR. This colorimetric assay could be a suitable alternative over existing methods during biological emergencies due to its simplicity, sensitive and cost effectiveness. PMID:29487580
This method provides a procedure for the determination of low-level orthophosphate concentrations normally found in estuarine and/or coastal waters. It is based upon the method of Murphy and Riley1 adapted for automated segmented flow analysis2 in which the two reagent solutions ...
A Colorimetric Microplate Assay for DNA-Binding Activity of His-Tagged MutS Protein.
Banasik, Michał; Sachadyn, Paweł
2016-09-01
A simple microplate method was designed for rapid testing DNA-binding activity of proteins. The principle of the assay involves binding of tested DNA by his-tagged protein immobilized on a nickel-coated ELISA plate, following colorimetric detection of biotinylated DNA with avidin conjugated to horseradish peroxidase. The method was used to compare DNA mismatch binding activities of MutS proteins from three bacterial species. The assay required relatively low amounts of tested protein (approximately 0.5-10 pmol) and DNA (0.1-10 pmol) and a relatively short time of analysis (up to 60 min). The method is very simple to apply and convenient to test different buffer conditions of DNA-protein binding. Sensitive colorimetric detection enables naked eye observations and quantitation with an ELISA reader. The performance of the assay, which we believe is a distinguishing trait of the method, is based on two strong and specific molecular interactions: binding of a his-tagged protein to a nickel-coated microplate and binding of biotinylated DNA to avidin. In the reported experiments, the solution was used to optimize the conditions for DNA mismatch binding by MutS protein; however, the approach could be implemented to test nucleic acids interactions with any protein of interest.
Wang, Shuqin; Deng, Wenfang; Yang, Lu; Tan, Yueming; Xie, Qingji; Yao, Shouzhuo
2017-07-26
Cu-MOF nanoparticles with an average diameter of 550 nm were synthesized from 2-aminoterephthalic acid and Cu(NO 3 ) 2 by a mixed solvothermal method. The Cu-MOF nanoparticles can show peroxidase-like activity that can catalyze 3,3',5,5'-tetramethylbenzidine to produce a yellow chromogenic reaction in the presence of H 2 O 2 . The presence of abundant amine groups on the surfaces of Cu-MOF nanoparticles enables facile modification of Staphylococcus aureus (S. aureus) aptamer on Cu-MOF nanoparticles. By combining Cu-MOF-catalyzed chromogenic reaction with aptamer recognition and magnetic separation, a simple, sensitive, and selective colorimetric method for the detection of S. aureus was developed.
Facial skin color measurement based on camera colorimetric characterization
NASA Astrophysics Data System (ADS)
Yang, Boquan; Zhou, Changhe; Wang, Shaoqing; Fan, Xin; Li, Chao
2016-10-01
The objective measurement of facial skin color and its variance is of great significance as much information can be obtained from it. In this paper, we developed a new skin color measurement procedure which includes following parts: first, a new skin tone color checker made of pantone Skin Tone Color Checker was designed for camera colorimetric characterization; second, the chromaticity of light source was estimated via a new scene illumination estimation method considering several previous algorithms; third, chromatic adaption was used to convert the input facial image into output facial image which appears taken under canonical light; finally the validity and accuracy of our method was verified by comparing the results obtained by our procedure with these by spectrophotometer.
NASA Astrophysics Data System (ADS)
Zareh Jonaghani, Mohammad; Zali-Boeini, Hassan
2017-05-01
A highly efficient and selective fluorescent and colorimetric chemosensor based on naphthothiazole skeleton was synthesized and its colorimetric and fluorescent properties were investigated. The sensor displays a rapid and highly selective colorimetric and fluorescence response toward Hg2 + without interference with other metal ions in CH3CN/H2O mixture (50/50, v/v). The detection limit for the fluorescent chemosensor S1 toward Hg2 + was 3.42 × 10- 8 M.
Accelerated Colorimetric Micro-assay for Screening Mold Inhibitors
Carol A. Clausen; Vina W. Yang
2014-01-01
Rapid quantitative laboratory test methods are needed to screen potential antifungal agents. Existing laboratory test methods are relatively time consuming, may require specialized test equipment and rely on subjective visual ratings. A quantitative, colorimetric micro-assay has been developed that uses XTT tetrazolium salt to metabolically assess mold spore...
Wren, J. J.; Wiggall, P. H.
1965-01-01
1. The conditions required for sensitive and specific colorimetric determination of proline with acidified ninhydrin were investigated. 2. A method applicable to protein samples was developed. 3. The only compound found to interfere appreciably was a hydroxyproline. PMID:14342233
NASA Astrophysics Data System (ADS)
Wang, Jiasi; Wu, Li; Ren, Jinsong; Qu, Xiaogang
2014-01-01
We developed a novel telomere complementary (TC) oligonucleotide modified AuNP probe (TC-AuNPs) for colorimetric analysis of telomerase activity. The mechanism of this method is that the telomerase reaction products (TRP), which can hybridize with the TC-AuNPs, are able to protect the AuNPs from the aggregation induced by salt. It is demonstrated that the colorimetric method enabled the analysis of the telomerase activity in 1000 HeLa cells with the naked eye, and down to 100 HeLa cells with the aid of UV-Vis spectroscopy. This strategy is not only convenient and sensitive, but also has a tunable dynamic range. The platform is also applicable for the initial screening of a telomerase inhibitor to discover new anticancer drugs.We developed a novel telomere complementary (TC) oligonucleotide modified AuNP probe (TC-AuNPs) for colorimetric analysis of telomerase activity. The mechanism of this method is that the telomerase reaction products (TRP), which can hybridize with the TC-AuNPs, are able to protect the AuNPs from the aggregation induced by salt. It is demonstrated that the colorimetric method enabled the analysis of the telomerase activity in 1000 HeLa cells with the naked eye, and down to 100 HeLa cells with the aid of UV-Vis spectroscopy. This strategy is not only convenient and sensitive, but also has a tunable dynamic range. The platform is also applicable for the initial screening of a telomerase inhibitor to discover new anticancer drugs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr05185d
NASA Astrophysics Data System (ADS)
Wang, Qing; Yang, Xiaohan; Yang, Xiaohai; Liu, Pei; Wang, Kemin; Huang, Jin; Liu, Jianbo; Song, Chunxia; Wang, Jingjing
2015-02-01
A novel unmodified gold nanoparticles (AuNPs)-based colorimetric strategy for label-free, specific and sensitive mercury ion (Hg2+) detection was demonstrated by using thymine-Hg2+-thymine (T-Hg2+-T) recognition mechanism and hybridization chain reaction (HCR) amplification strategy. In this protocol, a structure-switching probe (H0) was designed to recognize Hg2+ and then propagated a chain reaction of hybridization events between two other hairpin probes (H1 and H2). In the absence of Hg2+, all hairpin probes could stably coexist in solution, the exposed sticky ends of hairpin probes were capable of stabilizing AuNPs. As a result, salt-induced AuNPs aggregation could be effectively prevented. In the presence of Hg2+, thymine bases of H0 could specifically interact with Hg2+ to form stable T-Hg2+-T complex. Consequently, the hairpin structure of H0 probe was changed. As H1/H2 probes were added, the HCR process could be triggered and nicked double-helixes were formed. Since it was difficult for the formed nicked double-helixes to inhibit salt-induced AuNPs aggregation, a red-to-blue color change was observed in the colloid solution as the salt concentration increased. With the elegant amplification effect of HCR, a detection limit of around 30 nM was achieved (S/N = 3), which was about 1-2 orders of magnitudes lower than that of previous unmodified AuNPs-based colorimetric methods. By using the T-Hg2+-T recognition mechanism, high selectivity was also obtained. As an unmodified AuNPs-based colorimetric strategy, the system was simple in design, convenient in operation, and eliminated the requirements of separation processes, chemical modifications, and sophisticated instrumentations.
Ultrasensitive colorimetric detection of Cu2+ ion based on catalytic oxidation of L-cysteine.
Yin, Kun; Li, Bowei; Wang, Xiaochun; Zhang, Weiwei; Chen, Lingxin
2015-02-15
As an essential element, copper ion (Cu(2+)) plays important roles in human beings for its participation in diverse metabolic processes as a cofactor and/or a structural component of enzymes. However, excessive uptake of Cu(2+) ion gives rise to the risk of certain diseases. So, it is important to develop simple ways to monitor and detect Cu(2+) ion. In this study, a simple, facile colorimetric sensor for the ultrasensitive determination of Cu(2+) ion was developed based on the following principle: L-cysteine and 1-chloro-2,4-dinitrobenzene (CDNB) could be conjugated to form the yellow product 2,4-dinitrophenylcysteine (DNPC), which was measurable at 355nm; however, upon addition of Cu(2+) ion, the absorbance of DNPC would be decreased owing to the Cu(2+) ion catalytic oxidation of L-cysteine to L-cystine in the presence of O2. Thus, the colorimetric detection of Cu(2+) ion could be achieved. The optimal pH, buffer, temperature and incubation time for the colorimetric sensor were obtained of pH 6.8 in 0.1M HEPES solution, 90 °C and 50 min, respectively. A good linearity within the range of 0.8-10 nM (r = 0.996) was attained, with a high detectability up to 0.5nM. Analyses of Cu(2+) ion in drinking water, lake water, seawater and biological samples were carried out and the method performances were found to agree well with that obtained by ICP-MS. The developed simple colorimetric sensor proved applicable for Cu(2+) ion determination in real samples with high sensitivity and selectivity. Copyright © 2014 Elsevier B.V. All rights reserved.
Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-Li
2016-03-15
A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu(2+). The optical feature of 1 for Cu(2+) was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu(2+), the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu(2+) complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu(2+) with high sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.
Biochip Which Examines Hepatic Function by Employing Colorimetric Method
NASA Astrophysics Data System (ADS)
Oki, Akio; Ogawa, Hiroki; Takamura, Yuzuru; Horiike, Yasuhiro
2003-03-01
A biochip that is able to quickly analyze hepatic function from the bedside or at home was investigated. The chip essentially consisted of two chips, one that mixed the substrate buffer solution with serums using a centrifugal method and a chip that measured the amounts of γ-glutamyltranspeptidase (γ-GTP), glutamic oxaloacetic transaminase (GOT) and glutamic pyruvic transaminase (GPT) in the serums employing a colorimetric method. The chip should be inexpensive and disposable. Therefore the mixing and measurement channels were fabricated by molding their reverse patterns onto a poly (ethylene terephthalate) (PET) plate. Furthermore, a hydrophobic treatment was performed on the inner wall of the measurement channel to efficiently propagate the light efficiently in the channel. Subsequently, calibration curves were obtained for γ-GTP, GOT and GPT activity levels based on an endpoint method for the γ-GTP and a rate assay for GOT and GPT.
Doped colorimetric assay liposomes
Charych, Deborah; Stevens, Raymond C.
2001-01-01
The present invention provides compositions comprising colorimetric assay liposomes. The present invention also provides methods for producing colorimetric liposomes and calorimetric liposome assay systems. In preferred embodiments, these calorimetric liposome systems provide high levels of sensitivity through the use of dopant molecules. As these dopants allow the controlled destabilization of the liposome structure, upon exposure of the doped liposomes to analyte(s) of interest, the indicator color change is facilitated and more easily recognized.
Fu, Xiuli; Chen, Lingxin; Li, Jinhua
2012-08-21
A novel colorimetric method was developed for ultrasensitive detection of heparin based on self-assembly of gold nanoparticles (AuNPs) onto the surface of graphene oxide (GO). Polycationic protamine was used as a medium for inducing the self-assembly of citrate-capped AuNPs on GO through electrostatic interaction, resulting in a shift in the surface plasmon resonance (SPR) absorption of AuNPs and exhibiting a blue color. Addition of polyanionic heparin disturbed the self-assemble of AuNPs due to its strong affinity to protamine. With the increase of heparin concentration, the amounts of self-assembly AuNPs decreased and the color changed from blue to red in solution. Therefore, a "blue-to-red" colorimetric sensing strategy based on self-assembly of AuNPs could be established for heparin detection. Compared with the commonly reported aggregation-based methods ("red-to-blue"), the color change from blue to red was more eye-sensitive, especially in low concentration of target. Moreover, stronger interaction between protamine and heparin led to distinguish heparin from its analogues as well as various potentially coexistent physiological species. The strategy was simply achieved by the self-assembly nature of AuNPs and the application of two types of polyionic media, showing it to be label-free, simple, rapid and visual. This method could selectively detect heparin with a detection limit of 3.0 ng mL(-1) in standard aqueous solution and good linearity was obtained over the range 0.06-0.36 μg mL(-1) (R = 0.9936). It was successfully applied to determination of heparin in fetal bovine serum samples as low as 1.7 ng mL(-1) with a linear range of 0-0.8 μg mL(-1).
Rajatileka, Shavanti; Steven, Andrew; Hemingway, Janet; Ranson, Hilary; Paine, Mark; Vontas, John
2010-01-01
Background Insecticide-based methods represent the most effective means of blocking the transmission of vector borne diseases. However, insecticide resistance poses a serious threat and there is a need for tools, such as diagnostic tests for resistance detection, that will improve the sustainability of control interventions. The development of such tools for metabolism-based resistance in mosquito vectors lags behind those for target site resistance mutations. Methodology/Principal Findings We have developed and validated a simple colorimetric assay for the detection of Epsilon class Glutathione transferases (GST)-based DDT resistance in mosquito species, such as Aedes aegypti, the major vector of dengue and yellow fever worldwide. The colorimetric assay is based on the specific alkyl transferase activity of Epsilon GSTs for the haloalkene substrate iodoethane, which produces a dark blue colour highly correlated with AaGSTE2-2-overexpression in individual mosquitoes. The colour can be measured visually and spectrophotometrically. Conclusions/Significance The novel assay is substantially more sensitive compared to the gold standard CDNB assay and allows the discrimination of moderate resistance phenotypes. We anticipate that it will have direct application in routine vector monitoring as a resistance indicator and possibly an important impact on disease vector control. PMID:20824165
Guo, Jian-Feng; Huo, Dan-Qun; Yang, Mei; Hou, Chang-Jun; Li, Jun-Jie; Fa, Huan-Bao; Luo, Hui-Bo; Yang, Ping
2016-12-01
Herein, we have developed a simple, sensitive and paper-based colorimetric sensor for the selective detection of Chromium (Ⅵ) ions (Cr (VI)). Silanization-titanium dioxide modified filter paper (STCP) was used to trap bovine serum albumin capped gold nanoparticles (BSA-Au NPs), leading to the fabrication of BSA-Au NPs decorated membrane (BSA-Au NPs/STCP). The BSA-Au NPs/STCP operated on the principle that BSA-Au NPs anchored on the STCP were gradually etched by Cr (VI) as the leaching process of gold in the presence of hydrobromic acid (HBr) and hence induced a visible color change. Under optimum conditions, the paper-based colorimetric sensor showed clear color change after reaction with Cr (VI) as well as with favorable selectivity to a variety of possible interfering counterparts. The amount-dependent colorimetric response was linearly correlated with the Cr (VI) concentrations ranging from 0.5µM to 50.0µM with a detection limit down to 280nM. Moreover, the developed cost-effective colorimetric sensor has been successfully applied to real environmental samples which demonstrated the potential for field applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Hijaz, Faraj; Killiny, Nabil
2016-05-20
Delta-aminolevulinic (δ-ALA) acid is an important intermediate for tetrapyrroles biosynthesis and it has recently received great attention in plant physiology and human toxicology. However, the colorimetric method which is the most common method for determination of δ-ALA is time consuming and is not specific. In this study, a method for determination of δ-ALA in plant tissues was developed based on the trimethylsilyl (TMS) derivative of the pyrrole formed from the reaction of δ-ALA with ethyl acetoacetate via Knorr condensation. The δ-ALA in the HCl extract was reacted with ethyl acetoacetate to form a pyrrole. Then, the pyrrole compound was extracted using ethyl acetate and the solvent was evaporated to dryness. The dried sample was derivatized to its TMS ester and analyzed using GC-MS. The concentration of δ-ALA in citrus leaves incubated with levulinic acid was also determined by the conventional colorimetric method. The linear range was 10-200ppm in the full scan mode and 0.1-20ppm in the selected ion monitoring (SIM). The limit of detection was 6ppm in the full scan and 0.05ppm in SIM mode, representing a four-fold increase in sensitivity compared to the colorimetric method. The GC-MS method developed in this study is simple, accurate, sensitive, and could also be used to measure δ-ALA in other biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Measurement of Chlorine Dioxide in Water by DPD Colorimetric Method
NASA Astrophysics Data System (ADS)
Song, Min; Yan, Panping; Yao, Jun
2018-01-01
In order to solve the problems of chlorine dioxide in water by DPD colorimetric method, this paper discusses the effects of the formulation, temperature, color development time and amount of color reagent on the measurement process, improving the on-line instrument for domestic and drinking water in chlorine dioxide measurement precision and accuracy.
NASA Astrophysics Data System (ADS)
Leng, Yumin; He, Junbao; Li, Bo; Xing, Xiaojing; Guo, Yongming; Ye, Liqun; Lu, Zhiwen
2017-09-01
The different sized and shaped Au NPs have intrigued considerable attention, because they possess different surface plasma resonance (SPR) absorption bands and thus result in many colorimetric Au NP-based detection applications. In this article, four different sized and shaped Au NPs of nanodots/rods were prepared and characterized. The as-prepared Au NPs were modified by the negatively charged anions of [SCH2CO2]2- to investigate both the size and shape effects of modified Au NPs on colorimetric detection of Co2+ and the corresponding SPR absorption properties. The different-shaped Au NPs possess different SPR absorption properties. The Au nanorods appeared to be colorimetric sensitive for Co2+ sensing.
Liu, Jinchuan; Guan, Zheng; Lv, Zhenzhen; Jiang, Xiaoling; Yang, Shuming; Chen, Ailiang
2014-02-15
Gold nanoparticles (AuNPs) based fluorescence quenching or colorimetric aptasensor have been developed for many analytes recently largely because of the ease of detection, high sensitivity, and potential for high-throughput analysis. However, the effects of remnant non-AuNPs components in the colloid gold solution on these assays performance remain unclear. For the first time, we demonstrated that the remnant sodium citrate and the reaction products of three acids play counteractive roles in AuNPs based fluorescence quenching and colorimetric aptasensor in three ways in this study. First, the remnant sodium citrate in the colloid gold solution could increase the fluorescence intensity of FAM labeled on the aptamer that reduce the efficiency of AuNPs fluorescent quenching. Second, the reaction products of citric acid, HCl and ketoglutaric acid reduce the fluorescence recovery by quenching the fluorescence of FAM labeled on the aptamer dissociated from the surface of AuNPs upon addition of target. Lastly, the reaction products of three acids reduce the pH value of the colloid gold solution that reduce the sensitivity of AuNPs based colorimetric aptasensor by increasing the adsorption of aptamer to surface of AuNPs. With sulfadimethoxine and thrombin as model analytes, we found that water resuspended AuNPs can significantly increase the sensitivity by more than 10-fold for AuNPs based fluorescence quenching aptasensor. In the AuNPs based colorimetric aptasensor for sulfadimethoxine using the water resuspended AuNPs, the sensitivity also was increased by 10-fold compared with that of original AuNPs. The findings in this study provide theoretical guidance for further improving AuNPs based fluorescent quenching and colorimetric aptasensor by adjusting the composition of AuNPs solution. © 2013 Elsevier B.V. All rights reserved.
Sun, Xiange; Li, Bowei; Qi, Anjin; Tian, Chongguo; Han, Jinglong; Shi, Yajun; Lin, Bingcheng; Chen, Lingxin
2018-02-01
In this work, a novel rotational microfluidic paper-based device was developed to improve the accuracy and performance of the multiplexed colorimetric detection by effectively avoiding the diffusion of colorimetric reagent on the detection zone. The integrated paper-based rotational valves were used to control the connection or disconnection between detection zones and fluid channels. Based on the manipulation of the rotational valves, this rotational paper-based device could prevent the random diffusion of colorimetric reagent and reduce the error of quantitative analysis considerably. The multiplexed colorimetric detection of heavy metals Ni(II), Cu(II) and Cr(VI) were implemented on the rotational device and the detection limits could be found to be 4.8, 1.6, and 0.18mg/L, respectively. The developed rotational device showed the great advantage in improving the detection accuracy and was expected to be a low-cost, portable analytical platform for the on-site detection. Copyright © 2017 Elsevier B.V. All rights reserved.
Rapid colorimetric sensing of tetracycline antibiotics with in situ growth of gold nanoparticles.
Shen, Li; Chen, Jing; Li, Na; He, Pingli; Li, Zhen
2014-08-11
A colorimetric assay utilizing the formation of gold nanoparticles was developed to detect tetracycline antibiotics in fluidic samples. Tetracycline antibiotics showed the capability of directly reducing aurate salts into atomic gold which form gold nanoparticles spontaneously under proper conditions. The resulted gold nanoparticles showed characteristic plasmon absorbance at 526 nm, which can be visualized by naked eyes or with a spectrophotometer. UV-vis absorbance of the resulted gold nanoparticles is correlated directly with the concentrations of tetracycline antibiotics in the solution, allowing for quantitative colorimetric detection of tetracycline antibiotics. Reaction conditions, such as pH, temperature, reaction time, and ionic strength were optimized. Sensitivity of the colorimetric assay can be enhanced by the addition of gold nanoparticle seeds, a LOD as low as 20 ng mL(-1) can be achieved with the help of seed particles. The colorimetric assay showed minimum interference from ethanol, methanol, urea, glucose, and other antibiotics such as sulfonamides, amino glycosides etc. Validity of the method was also evaluated on urine samples spiked with tetracycline antibiotics. The method provides a broad spectrum detection method for rapid and sensitive detection of reductive substances such as tetracycline antibiotics in liquid and biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Chuang, Yen-Jun; Zhou, Xichun; Pan, Zhengwei; Turchi, Craig
2009-01-01
Carbohydrate functionalized nanoparticles, i.e., the glyconanoparticles, have wide application ranging from studies of carbohydrate-protein interactions, in vivo cell imaging, biolabeling, etc. Currently reported methods for preparation of glyconanoaprticles require multi-step modifications of carbohydrates moieties to conjugate to nanoparticle surface. However, the required synthetic manipulations are difficult and time consuming. We report herewith a simple and versatile method for preparing glyconanoparticles. This method is based on the utilization of clean and convenient microwave irradiation energy for one-step, site-specific conjugation of unmodified carbohydrates onto hydrazide-functionalized Au nanoparticles. A colorimetric assay that utilizes the ensemble of gold glyconanoparticles and Concanavalin A (ConA) was also presented. This feasible assay system was developed to analyze multivalent interactions and to determine the dissociation constant (Kd) for five kind of Au glyconanoparticles with lectin. Surface plasmon changes of the Au glyconanparticles as a function of lectin-carbohydrate interactions were measured and the dissociation constants were determined based on non-linear curve fitting. The strength of the interaction of carbohydrates with ConA was found to be as follows: Maltose > Mannose > Glucose > Lactose > MAN5. PMID:19698698
Colorimetric determination of sildenafil citrate (Viagra) through ion-associate complex formation.
Amin, Alaa S; Moustafa, Moustafa E; El-Dosoky, Reham
2009-01-01
A simple, quick, accurate, and sensitive colorimetric method is described for the determination of sildenafil citrate (SLD). The method is based on the reaction of SLD with Congo Red, Sudan II, and Gentian Violet in buffered aqueous solutions at pH 2.5, 6.5, and 11.0, respectively, to give highly colored soluble ion-associate complex species; the colored products are quantitated colorimetrically at 523, 554, and 569 nm, respectively. The various experimental conditions were optimized. The stoichiometric ratio was found to be 1:1 for all ion associates; the calculated logarithmic stability constants were 8.51, 7.79, and 5.58, respectively. Beer's law was obeyed over the concentration range of 0.2-7.0 microg/mL, whereas the Ringbom optimum concentration range was 0.4-6.5 microg/mL. Values for molar absorptivity, Sandell sensitivity, and detection and quantification limits were also calculated. The proposed method was successfully applied to the determination of SLD in Viagra tablets and in serum samples by using the technique of standard additions with mean accuracy values of 100.06 +/- 1.14, 99.87 +/- 0.70, and 99.86 +/- 0.97% for Viagra tablets and 99.88 +/- 0.60, 99.90 +/- 0.90, and 100.24 +/- 0.80% for serum samples, respectively.
Zinc Biosorption by Seaweed Illustrated by the Zincon Colorimetric Method and the Langmuir Isotherm
ERIC Educational Resources Information Center
Areco, Maria Mar; dos Santos Afonso, Maria; Valdman, Erika
2007-01-01
An experiment is conducted to promote biotechnology knowledge that is an emerging technology on cleaning treatment, showing the potential of seaweed to remove heavy-metal ions from solution. The rapid and accurate determination of zinc in aqueous solution by the zincon colorimetric method gives an interesting and simple experiment for any…
Fabricating a UV-Vis and Raman Spectroscopy Immunoassay Platform.
Hanson, Cynthia; Israelsen, Nathan D; Sieverts, Michael; Vargis, Elizabeth
2016-11-10
Immunoassays are used to detect proteins based on the presence of associated antibodies. Because of their extensive use in research and clinical settings, a large infrastructure of immunoassay instruments and materials can be found. For example, 96- and 384-well polystyrene plates are available commercially and have a standard design to accommodate ultraviolet-visible (UV-Vis) spectroscopy machines from various manufacturers. In addition, a wide variety of immunoglobulins, detection tags, and blocking agents for customized immunoassay designs such as enzyme-linked immunosorbent assays (ELISA) are available. Despite the existing infrastructure, standard ELISA kits do not meet all research needs, requiring individualized immunoassay development, which can be expensive and time-consuming. For example, ELISA kits have low multiplexing (detection of more than one analyte at a time) capabilities as they usually depend on fluorescence or colorimetric methods for detection. Colorimetric and fluorescent-based analyses have limited multiplexing capabilities due to broad spectral peaks. In contrast, Raman spectroscopy-based methods have a much greater capability for multiplexing due to narrow emission peaks. Another advantage of Raman spectroscopy is that Raman reporters experience significantly less photobleaching than fluorescent tags 1 . Despite the advantages that Raman reporters have over fluorescent and colorimetric tags, protocols to fabricate Raman-based immunoassays are limited. The purpose of this paper is to provide a protocol to prepare functionalized probes to use in conjunction with polystyrene plates for direct detection of analytes by UV-Vis analysis and Raman spectroscopy. This protocol will allow researchers to take a do-it-yourself approach for future multi-analyte detection while capitalizing on pre-established infrastructure.
NASA Astrophysics Data System (ADS)
Amini, Bahram; Kamali, Mehdi; Salouti, Mojtaba; Yaghmaei, Parichehreh
2018-06-01
Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanoparticles (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562 nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50 ng mL-1 with the limit detection of 9.899 ng mL-1. Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 103 to 108 CFU mL-1 in real samples with a detection limit of 320 CFU mL-1.
Erçağ, Erol; Uzer, Ayşem; Apak, Reşat
2009-05-15
Because of the extremely heterogeneous distribution of explosives in contaminated soils, on-site colorimetric methods are efficient tools to assess the nature and extent of contamination. To meet the need for rapid and low-cost chemical sensing of explosive traces or residues in soil and post-blast debris, a colorimetric absorption-based sensor for trinitrotoluene (TNT) determination has been developed. The charge-transfer (CT) reagent (dicyclohexylamine, DCHA) is entrapped in a polyvinylchloride (PVC) polymer matrix plasticised with dioctylphtalate (DOP), and moulded into a transparent sensor membrane sliced into test strips capable of sensing TNT showing an absorption maximum at 530 nm when placed in a 1-mm spectrophotometer cell. The sensor gave a linear absorption response to 5-50 mg L(-1) TNT solutions in 30% aqueous acetone with limit of detection (LOD): 3 mg L(-1). The sensor is only affected by tetryl, but not by RDX, pentaerythritoltetranitrate (PETN), dinitrotoluene (DNT), and picric acid. The proposed method was statistically validated for TNT assay against high performance liquid chromatography (HPLC) using a standard sample of Comp B. The developed sensor was relatively resistant to air and water, was of low-cost and high specificity, gave a rapid and reproducible response, and was suitable for field use of TNT determination in both dry and humid soil and groundwater with a portable colorimeter.
Arkhipova, Viktoriya V; Apyari, Vladimir V; Dmitrienko, Stanislava G
2015-03-15
Desensitized ionene-stabilized gold nanoparticles have been prepared and applied as a colorimetric probe for the single-step test for sulfate ions at the relatively high concentration level. The approach is based on aggregation of the nanoparticles leading to the change in absorption spectra and color of the solution. These nanoparticles are characterized by the decreased sensitivity due to both electrostatic and steric stabilization, which allows for simple, and rapid direct single-step determination of sulfate at the relatively high concentration level in real water samples without sample pretreatment or dilution. Influence of different factors (the time of interaction, pH, the concentrations of sulfate ions and the nanoparticles) on the aggregation and analytical performance of the procedure was investigated. The method allows for the determination of sulfate ions in the mass range of 0.2-0.4 mg with RSD of 5% from the sample volume of less than 2 mL. It has a sharp dependence of the colorimetric response on the concentration of sulfate, which makes it prospective for indicating deviations of the sulfate concentration regarding some declared value chosen within the above range. The time of the analysis is 2 min. The method was applied to the analysis of mineral water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Colorimetric and fluorescent detection of hydrazine with high sensitivity and excellent selectivity
NASA Astrophysics Data System (ADS)
Shi, Bingjie; Qi, Sujie; Yu, Mingming; Liu, Chunxia; Li, Zhanxian; Wei, Liuhe; Ni, Zhonghai
2018-01-01
It is critical to develop probes for rapid, selective, and sensitive detection of the highly toxic hydrazine in both environmental and biological science. In this work, under mild condition, a novel colorimetric and off-on fluorescent probe was synthesized for rapid recognition of hydrazine with excellent selectivity over other various species including some biological species, metal ions and anions. The limit of quantification (LOQ) value was 1.5 × 10- 4 M-3.2 × 10- 3 M (colorimetric method) and 1.5 × 10- 4 M - 3.2 × 10- 3 M (fluorescent method) with as low as detection limit of 46.2 μM.
Colorimetric determination of cyanide liberated from apricot kernels.
Egli, K L
1977-07-01
A simple colorimetric method is described for determining the quantity of hydrogen cyanide produced by the spontaneous decomposition of amygdalin in apricot kernels. The evolved cyanide is collected in sodium hydroxide solution and assayed colorimetrically by reaction with picric acid. Results for duplicate assays, 3.02 and 3.06 mg CN-/g, compare well with those obtained by AOAC method 26.115 which specifies steam distillation and silver nitrate titration; results for triplicate assays were 3.02, 3.03, and 3.08 mg CN-/g by the latter. Recovery of cyanide from potassium cyanide at a level equivalent to 243 microgram CN-/g was 101.0%.
NASA Astrophysics Data System (ADS)
Shahrivari, Shima; Faridbod, Farnoush; Ganjali, Mohammad Reza
2018-02-01
In this work, a rapid, selective naked eyes colorimetric chemical probe for the detection of Cr3 + was developed based on functionalization of gold nanoparticles. For this purpose, surface of Au NPs was functionalized using 4-amino-5-methyl-4H-1,2,4-triazole-3-thiol (AMTT). Through colorimetric studies, it was found that in the presence of Cr3 + ions, AMTT-Au NPs instantly aggregated and resulted in a color change of the solution from red to blue. The color change of AMTT-Au NPs due to the aggregation induced by Cr3 + can be seen with even naked eyes and also by UV-Vis spectroscopy with a detection limit of 1.8 μM and 0.1 μM, respectively. AMTT-Au NPs showed excellent selectivity toward Cr3 + compared to other cations tested, including K+, Na+, Cs+, Fe3 +, Ni2 +, Cu2 +, Co2 +, Zn2 +, Ba2 +, Ca2 +, Mg2 +, Cd2 +, Pb2 +, Hg2 + ions and especially all trivalent lanthanide ions. The absorbance ratio (A650/A525) was linear toward Cr3 + concentrations in the range of 0.6-6.1 μM (R2 = 0.996). The best response was achieved over a pH range of 3-5. Furthermore, the proposed colorimetric method based on AMTT-Au NPs was successfully used for Cr3 + ion detection in plasma sample and some water samples.
A novel reflectance-based aptasensor using gold nanoparticles for the detection of oxytetracycline.
Seo, Ho Bin; Kwon, Young Seop; Lee, Ji-eun; Cullen, David; Noh, Hongseok Moses; Gu, Man Bock
2015-10-07
We present a novel reflectance-based colorimetric aptasensor using gold nanoparticles for the detection of oxytetracycline for the first time. It was found that the reflectance-based measurement at two wavelengths (650 and 520 nm) can generate more stable and sensitive signals than absorbance-based sensors to determine the aggregation of AuNPs, even at high AuNP concentrations. One of the most common antibacterial agents, oxytetracycline (OTC), was detected at concentrations as low as 1 nM in both buffer solution and tap water, which was 25-fold more sensitive, compared to the previous absorbance-based colorimetric aptasensors. This reflectance-based colorimetric aptasensor using gold nanoparticles is considered to be a better platform for portable sensing of small molecules using aptamers.
Parihar, Sanjay; Boricha, Vinod P; Jadeja, R N
2015-03-01
Two novel Rhodamine-pyrazolone-based colorimetric off-on fluorescent chemosensors for Fe(3+) ions were designed and synthesized using pyrazolone as the recognition moiety and Rhodamine 6G as the signalling moiety. The photophysical properties and Fe(3+) -binding properties of sensors L(1) and L(2) in acetonitrile-aqueous solution were also investigated. Both sensors successfully exhibit a remarkably 'turn-on' response, toward Fe(3+) , which was attributed to 1: 2 complex formation between Fe(3+) and L(1) /L(2) . The fluorescent and colorimetric response to Fe(3+) can be detected by the naked eye, which provides a facile method for the visual detection of Fe(3+) . Copyright © 2014 John Wiley & Sons, Ltd.
Velmathi, Sivan; Reena, Vijayaraghavan; Suganya, Sivalingam; Anandan, Sambandam
2012-01-01
An efficient colorimetric sensor with pyrrole-NH moiety as binding site and nitro group as a signaling unit has been synthesized by a one step procedure and characterized by spectroscopic techniques, which displays excellent selectivity and sensitivity for fluoride and hydroxide ions. The hydrogen bonding with these anions provides remarkable colorimetric responses. (1)H NMR and FT IR studies has been carried out to confirm the hydrogen bonding. UV-vis and fluorescence spectral changes can be exploited for real time and on site application.
NASA Astrophysics Data System (ADS)
Marsella, Alessandra; Valentini, Paola; Tarantino, Paolo; Congedo, Maurizio; Pompa, Pier Paolo
2016-04-01
We report a simple, rapid and low-cost test, based on gold nanoparticles, for the naked-eye colorimetric detection of a signature of single nucleotide polymorphisms (SNPs) relevant for the personalized medicine of psoriasis patients. We validated the colorimetric assay on real-world DNA samples from a cohort of 30 psoriasis patients and we compared the results, in double-blind, with those obtained with two state-of-the-art instrumental techniques, namely reverse dot blotting and direct sequencing, finding 100% agreement. We demonstrated high accuracy, sensitivity and specificity of the colorimetric test that can be easily adapted for the genotypization of different SNPs, important for the pharmacogenomics of various diseases, and in other fields, such as food traceability and population structure analysis.
Garcia, Rafaela Alvim; Vanelli, Chislene Pereira; Pereira Junior, Olavo Dos Santos; Corrêa, José Otávio do Amaral
2018-06-19
Hydroelectrolytic disorders are common in clinical situations and may be harmful to the patient, especially those involving plasma sodium and potassium dosages. Among the possible methods for the dosages are flame photometry, ion-selective electrode (ISE) and colorimetric enzymatic method. We analyzed 175 samples in the three different methods cited from patients attending the laboratory of the University Hospital of the Federal University of Juiz de Fora. The values obtained were statistically treated using SPSS 19.0 software. The present study aims to evaluate the impact of the use of these different methods in the determination of plasma sodium and potassium. The averages obtained for sodium and potassium measurements by flame photometry were similar (P > .05) to the means obtained for the two electrolytes by ISE. The averages obtained by the colorimetric enzymatic method presented statistical difference in relation to ISE, both for sodium and potassium. In the correlation analysis, both flame photometry and colorimetric enzymatic showed a strong correlation with the ISE method for both dosages. At the first time in the same work sodium and potassium were analyzed by three different methods and the results allowed us to conclude that the methods showed a positive and strong correlation, and can be applied in the clinical routine. © 2018 Wiley Periodicals, Inc.
Spectral gamuts and spectral gamut mapping
NASA Astrophysics Data System (ADS)
Rosen, Mitchell R.; Derhak, Maxim W.
2006-01-01
All imaging devices have two gamuts: the stimulus gamut and the response gamut. The response gamut of a print engine is typically described in CIE colorimetry units, a system derived to quantify human color response. More fundamental than colorimetric gamuts are spectral gamuts, based on radiance, reflectance or transmittance units. Spectral gamuts depend on the physics of light or on how materials interact with light and do not involve the human's photoreceptor integration or brain processing. Methods for visualizing a spectral gamut raise challenges as do considerations of how to utilize such a data-set for producing superior color reproductions. Recent work has described a transformation of spectra reduced to 6-dimensions called LabPQR. LabPQR was designed as a hybrid space with three explicit colorimetric axes and three additional spectral reconstruction axes. In this paper spectral gamuts are discussed making use of LabPQR. Also, spectral gamut mapping is considered in light of the colorimetric-spectral duality of the LabPQR space.
Gao, Zhuangqiang; Hou, Li; Xu, Mingdi; Tang, Dianping
2014-01-01
Methods based on enzyme labels have been developed for colorimetric immunoassays, but most involve poor sensitivity and are unsuitable for routine use. Herein, we design an enhanced colorimetric immunoassay for prostate-specific antigen (PSA) coupling with an enzyme-cascade-amplification strategy (ECAS-CIA). In the presence of target PSA, the labeled alkaline phosphatase on secondary antibody catalyzes the formation of palladium nanostructures, which catalyze 3,3′,5,5′-tetramethylbenzidine-H2O2 system to produce the colored products, thus resulting in the signal cascade amplification. Results indicated that the ECAS-CIA presents good responses toward PSA, and allows detection of PSA at a concentration as low as 0.05 ng mL−1. Intra- and inter-assay coefficients of variation are below 9.5% and 10.7%, respectively. Additionally, the methodology is validated for analysis of clinical serum specimens with consistent results obtained by PSA ELISA kit. Importantly, the ECAS-CIA opens a new horizon for protein diagnostics and biosecurity. PMID:24509941
Testolin, Renan C; Almeida, Tito C M; Polette, Marcus; Branco, Joaquim O; Fischer, Larissa L; Niero, Guilherme; Poyer-Radetski, Gabriel; Silva, Valéria C; Somensi, Cleder A; Corrêa, Albertina X R; Corrêa, Rogério; Rörig, Leonardo R; Itokazu, Ana Gabriela; Férard, Jean-François; Cotelle, Sylvie; Radetski, Claudemir M
2017-05-15
There is scientific evidence that beach sands are a significant contributor to the pathogen load to which visitors are exposed. To develop beach quality guidelines all beach zones must be included in microbiological evaluations, but monitoring methods for beach sand quality are relatively longstanding, expensive, laborious and require moderate laboratory infrastructure. This paper aimed to evaluate the microorganism activity in different beach zones applying and comparing a classical method of membrane filtration (MF) with two colorimetric screening methods based on fluorescein (FDA) and tetrazolium (TTC) salt biotransformation to evaluate a new rapid and low-cost method for beach sand microbiological contamination assessments. The colorimetric results can help beach managers to evaluate rapidly and at low cost the microbiological quality of different beach zones in order to decide whether remedial actions need to be adopted to prevent exposure of the public to microbes due to beach sand and/or water contamination. Copyright © 2017. Published by Elsevier Ltd.
Tsai, Wei-Kai; Lai, Yung-Sheng; Tseng, Po-Jung; Liao, Chia-Hsien; Chan, Yang-Hsiang
2017-09-13
Semiconducting polymer dots (Pdots) have recently emerged as a novel type of ultrabright fluorescent probes that can be widely used in analytical sensing and material science. Here, we developed a dual visual reagent based on Pdots for anticounterfeiting applications. We first designed and synthesized two types of photoswitchable Pdots by incorporating photochromic dyes with multicolor semiconducting polymers to modulate their emission intensities and wavelengths. The resulting full-color Pdot assays showed that the colorimetric and fluorescent dual-readout abilities enabled the Pdots to serve as an anticounterfeiting reagent with low background interference. We also doped these Pdots into flexible substrates and prepared these Pdots as inks for pen handwriting as well as inkjet printing. We further applied this reagent in printing paper and checks for high-security anticounterfeiting purposes. We believe that this dual-readout method based on Pdots will create a new avenue for developing new generations of anticounterfeiting technologies.
Okochi, Mina; Kuboyama, Masashi; Tanaka, Masayoshi; Honda, Hiroyuki
2015-09-01
Label-free colorimetric assays using metallic nanoparticles have received much recent attention, for their application in simple and sensitive methods for detection of biomolecules. Short peptide probes that can bind to analyte biomolecules are attractive ligands in molecular nanotechnology; however, identification of biological recognition motifs is usually based on trial-and-error experiments. Herein, a peptide probe was screened for colorimetric detection of angiotensin II (Ang II) using a mechanism for non-crosslinking aggregation of silver nanoparticles (AgNPs). The dual-function peptides, which bind to the analyte and induce AgNP aggregation, were identified using a two-step strategy: (1) screening of an Ang II-binding peptide from an Ang II receptor sequence library, using SPOT technology, which enable peptides synthesis on cellulose membranes via an Fmoc method and (2) selection of peptide probes that effectively induce aggregation of AgNPs using a photolinker modified peptide array. Using the identified peptide probe, KGKNKRRR, aggregation of AgNPs was detected by observation of a pink color in the absence of Ang II, whereas AgNPs remained dispersed in the presence of Ang II (yellow). The color changes were not observed in the presence of other hormone molecules. Ang II could be detected within 15 min, with a detection limit of 10 µM, by measuring the ratio of absorbance at 400 nm and 568 nm; the signal could also be observed with the naked eye. These data suggest that the peptide identified here could be used as a probe for simple and rapid colorimetric detection of Ang II. This strategy for the identification of functional peptides shows promise for the development of colorimetric detection of various diagnostically important biomolecules. Copyright © 2015 Elsevier B.V. All rights reserved.
Wu, Luling; Li, Xiaolin; Huang, Chusen; Jia, Nengqin
2016-08-16
As traditional pH meters cannot work well for minute regions (such as subcellular organelles) and in harsh media, molecular pH-sensitive devices for monitoring pH changes in diverse local heterogeneous environments are urgently needed. Here, we report a new dual-modal colorimetric/fluorescence merocyanine-based molecular probe (CPH) for ratiometric sensing of pH. Compared with previously reported pH probes, CPH bearing the benzyl group at the nitrogen position of the indolium group and the phenol, which is used as the acceptor for proton, could respond to pH changes immediately through both the ratiometric fluorescence signal readout and naked-eye colorimetric observation. The sensing process was highly stable and reversible. Most importantly, the suitable pKa value (6.44) allows CPH to presumably accumulate in lysosomes and become a lysosome-target fluorescent probe. By using CPH, the intralysosomal pH fluctuation stimulated by antimalaria drug chloroquine was successfully tracked in live cells through the ratiometric fluorescence images. Additionally, CPH could be immobilized on test papers, which exhibited a rapid and reversible colorimetric response to acid/base vapor through the naked-eye colorimetric analysis. This proof-of-concept study presents the potential application of CPH as a molecular tool for monitoring intralysosomal pH fluctuation in live cells, as well as paves the way for developing the economic, reusable, and fast-response optical pH meters for colorimetric sensing acid/base vapor with direct naked-eye observation.
Vitkova, O N; Kapustina, T P; Mikhailova, V V; Safonov, G A; Vlasova, N N; Belousova, R V
2015-01-01
The goal of this work was to demonstrate the results of the development of the enzyme-linked immunosorbent tests with chemiluminescence detection and colorimetric detection of specific viral antigens and antibodies for identifying the avian influenza and the Newcastle disease viruses: high sensitivity and specificity of the immuno- chemiluminescence assay, which are 10-50 times higher than those of the ELISA colorimetric method. The high effectiveness of the results and the automation of the process of laboratory testing (using a luminometer) allow these methods to be recommended for including in primary screening tests for these infectious diseases.
Redmile-Gordon, M A; Armenise, E; White, R P; Hirsch, P R; Goulding, K W T
2013-12-01
Soil extracts usually contain large quantities of dissolved humified organic material, typically reflected by high polyphenolic content. Since polyphenols seriously confound quantification of extracted protein, minimising this interference is important to ensure measurements are representative. Although the Bradford colorimetric assay is used routinely in soil science for rapid quantification protein in soil-extracts, it has several limitations. We therefore investigated an alternative colorimetric technique based on the Lowry assay (frequently used to measure protein and humic substances as distinct pools in microbial biofilms). The accuracies of both the Bradford assay and a modified Lowry microplate method were compared in factorial combination. Protein was quantified in soil-extracts (extracted with citrate), including standard additions of model protein (BSA) and polyphenol (Sigma H1675-2). Using the Lowry microplate assay described, no interfering effects of citrate were detected even with concentrations up to 5 times greater than are typically used to extract soil protein. Moreover, the Bradford assay was found to be highly susceptible to two simultaneous and confounding artefacts: 1) the colour development due to added protein was greatly inhibited by polyphenol concentration, and 2) substantial colour development was caused directly by the polyphenol addition. In contrast, the Lowry method enabled distinction between colour development from protein and non-protein origin, providing a more accurate quantitative analysis. These results suggest that the modified-Lowry method is a more suitable measure of extract protein (defined by standard equivalents) because it is less confounded by the high polyphenolic content which is so typical of soil extracts.
Multiplexed Paper Analytical Device for Quantification of Metals using Distance-Based Detection
Cate, David M.; Noblitt, Scott D.; Volckens, John; Henry, Charles S.
2015-01-01
Exposure to metal-containing aerosols has been linked with adverse health outcomes for almost every organ in the human body. Commercially available techniques for quantifying particulate metals are time-intensive, laborious, and expensive; often sample analysis exceeds $100. We report a simple technique, based upon a distance-based detection motif, for quantifying metal concentrations of Ni, Cu, and Fe in airborne particulate matter using microfluidic paper-based analytical devices. Paper substrates are used to create sensors that are self-contained, self-timing, and require only a drop of sample for operation. Unlike other colorimetric approaches in paper microfluidics that rely on optical instrumentation for analysis, with distance-based detection, analyte is quantified visually based on the distance of a colorimetric reaction, similar to reading temperature on a thermometer. To demonstrate the effectiveness of this approach, Ni, Cu, and Fe were measured individually in single-channel devices; detection limits as low as 0.1, 0.1, and 0.05 µg were reported for Ni, Cu, and Fe. Multiplexed analysis of all three metals was achieved with detection limits of 1, 5, and 1 µg for Ni, Cu, and Fe. We also extended the dynamic range for multi-analyte detection by printing concentration gradients of colorimetric reagents using an off the shelf inkjet printer. Analyte selectivity was demonstrated for common interferences. To demonstrate utility of the method, Ni, Cu, and Fe were measured from samples of certified welding fume; levels measured with paper sensors matched known values determined gravimetrically. PMID:26009988
Mustafa, Ahmad; Karmali, Amin; Abdelmoez, Wael
2016-01-01
The present work involves a sensitive high-throughput microtiter plate based colorimetric assay for estimating lipase activity using cupric acetate pyridine reagent (CAPR). In the first approach, three factors two levels factorial design methodology was used to evaluate the interactive effect of different parameters on the sensitivity of the assay method. The optimization study revealed that the optimum CAPR concentration was 7.5% w/v, the optimum solvent was heptane and the optimum CAPR pH was 6. In the second approach, the optimized colorimetric microplate assay was used to measure lipase activity based on enzymatic hydrolysis of olive oil emulsion substrate at 37°C and 150 rpm. The emulsion substrates were formulated by using olive oil, triton X-100 (10% v/v in pH 8) and sodium phosphate buffer of pH 8 in ratio of 1:1:1 in the case of Candida sp. lipase. While in the case of immobilized lipozyme RMIM, The emulsion substrates were formulated by using olive oil, triton X-100 (1% v/v in pH 8) and sodium phosphate buffer of pH 8 in ratio of 2:1:1. Absorbance was measured at 655 nm. The stability of this assay (in terms of colored heptane phase absorbance readings) retained more than 92.5% after 24 h at 4°C compared to the absorbance readings measured at zero time. In comparison with other lipase assay methods, beside the developed sensitivity, the reproducibility and the lower limit of detection (LOD) of the proposed method, it permits analyzing of 96 samples at one time in a 96-well microplate. Furthermore, it consumes small quantities of chemicals and unit operations.
Majdinasab, Marjan; Hosseini, Seyed Mohammad Hashem; Sepidname, Marziyeh; Negahdarifar, Manizheh; Li, Peiwu
2018-05-01
Alginate is a non-toxic, renewable, and linear copolymer obtained from the brown algae Laminaria digitata that can be easily shaped into beads. Its good gel forming properties have made it useful for entrapping food and pharmaceutical ingredients. In this study, alginate beads were used in a novel application as a colorimetric sensor in food intelligent packaging. Colorimetric sensor was developed through entrapping red cabbage extract as a pH indicator in alginate beads. The pH indicator beads were used in rainbow trout packaging for monitoring fillets spoilage. Color change of beads during fish storage was measured using the CIELab method. The alginate bead colorimetric sensor is validated by measuring total volatile basic nitrogen (TVB-N) levels and microbial populations in fish samples. Moreover, peroxide value (PV) and thiobarbituric acid reactive substances (TBARS) were evaluated during storage. Results indicated that increasing the bacterial population during storage and production of proteolytic enzymes resulted in protein degradation, accumulation of volatile amine compounds, increase in the pH and finally color change of alginate beads. The values of TVB-N, pH, PV and TBARS increased with time of storage. The results of TVB-N and microbial growth were in accordance with color change of beads and CIELab data. Therefore, the proposed system enjoys a high sensitivity to pH variations and is capable of monitoring the spoilage of fish or other protein-rich products through its wide range of color changes. The alginate beads containing the red cabbage extract can, thus, be used as a low-cost colorimetric sensor for intelligent packaging applications.
NASA Astrophysics Data System (ADS)
Kandi, Saeideh Gorji; Nourmohammadian, Farahnaz
2013-10-01
In the present study, colorimetric characteristics of six photochromic bis-azospiropyrans based dyes are investigated. The colorimetric axes of these dyes in terms of hue, chroma and lightness are considered via UV exposure time. Results showed that, the hue angle of these dyes changes rapidly at the first times of UV irradiation, and then remains almost constant. However, chroma and lightness continuously change till about 80-240 s for different dyes. In addition, it is shown that variations of lightness and chroma by UV exposure time have an exponential trend, which can be modeled mathematically.
Mahapatra, Ajit Kumar; Manna, Saikat Kumar; Maiti, Kalipada; Mondal, Sanchita; Maji, Rajkishor; Mandal, Debasish; Mandal, Sukhendu; Uddin, Md Raihan; Goswami, Shyamaprosad; Quah, Ching Kheng; Fun, Hoong-Kun
2015-02-21
Azodye-rhodamine hybrid colorimetric fluorescent probe (L) has been designed and synthesized. The structure of L has been established based on single crystal XRD. It has been shown to act as a selective turn-on fluorescent chemosensor for Pd(2+) with >40 fold enhancement by exhibiting red emission among the other 27 cations studied in aqueous ethanol. The coordination features of the species of recognition have been computationally evaluated by DFT methods and found to have a distorted tetrahedral Pd(2+) center in the binding core. The probe (L) has been shown to detect Pd up to 0.45 μM at pH 7.4. Furthermore, the probe can be used to image Pd(2+) in living cells.
Method for hue plane preserving color correction.
Mackiewicz, Michal; Andersen, Casper F; Finlayson, Graham
2016-11-01
Hue plane preserving color correction (HPPCC), introduced by Andersen and Hardeberg [Proceedings of the 13th Color and Imaging Conference (CIC) (2005), pp. 141-146], maps device-dependent color values (RGB) to colorimetric color values (XYZ) using a set of linear transforms, realized by white point preserving 3×3 matrices, where each transform is learned and applied in a subregion of color space, defined by two adjacent hue planes. The hue plane delimited subregions of camera RGB values are mapped to corresponding hue plane delimited subregions of estimated colorimetric XYZ values. Hue planes are geometrical half-planes, where each is defined by the neutral axis and a chromatic color in a linear color space. The key advantage of the HPPCC method is that, while offering an estimation accuracy of higher order methods, it maintains the linear colorimetric relations of colors in hue planes. As a significant result, it therefore also renders the colorimetric estimates invariant to exposure and shading of object reflection. In this paper, we present a new flexible and robust version of HPPCC using constrained least squares in the optimization, where the subregions can be chosen freely in number and position in order to optimize the results while constraining transform continuity at the subregion boundaries. The method is compared to a selection of other state-of-the-art characterization methods, and the results show that it outperforms the original HPPCC method.
Sutariya, Pinkesh G; Pandya, Alok; Lodha, Anand; Menon, Shobhana K
2016-01-15
A new, simple, ultra-sensitive and selective approach has been reported for the "on spot" colorimetric detection of creatinine based on calix[4]arene functionalized gold nanoparticles (AuNPs) with excellent discrimination in the presence of other biomolecules. The lower detection limit of the method is 2.16nM. The gold nanoparticles and p-tert-butylcalix[4]arene were synthesized by microwave assisted method. Specifically, in our study, we used dynamic light scattering (DLS) which is a powerful method for the determination of small changes in particle size, improved selectivity and sensitivity of the creatinine detection system over colorimetric method. The nanoassembly is characterized by Transmission electron microscopy (TEM), DLS, UV-vis and ESI-MS spectroscopy, which demonstrates the binding affinity due its ability of hydrogen bonding and electrostatic interaction between -NH group of creatinine and pSDSC4. It exhibits fast response time (<60s) to creatinine and has long shelf-life (>5 weeks). The developed pSDSC4-AuNPs based creatinine biosensor will be established as simple, reliable and accurate tool for the determination of creatinine in human urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Deng, Jingjing; Ma, Wenjie; Yu, Ping; Mao, Lanqun
2015-07-07
This study demonstrates a new strategy for colorimetric and fluorescent dual mode sensing of alcoholic strength (AS) in spirit samples based on stimuli-responsive infinite coordination polymers (ICPs). The ICP supramolecular network is prepared with 1,4-bis(imidazol-1-ylmethyl)benzene (bix) as the ligand and Zn(2+) as the central metal ion in ethanol, in which rhodamine B (RhB) is encapsulated through self-adaptive chemistry. In pure ethanol solvent, the as-formed RhB/Zn(bix) is well dispersed and quite stable. However, the addition of water into the ethanol dispersion of RhB/Zn(bix) destroys Zn(bix) network structure, resulting in the release of RhB from ICP into the solvent. As a consequence, the solvent displays the color of released RhB and, at the meantime, turns on the fluorescence of RhB, which constitutes a new mechanism for colorimetric and fluorescent dual mode sensing of AS in commercial spirit samples. With the method developed here, we could distinguish the AS of different commercial spirit samples by the naked eye within a wide linear range from 20 to 100% vol and by monitoring the increase of fluorescent intensity of the released RhB. This study not only offers a new method for on-spot visible detection of AS in commercial spirit samples, but also provides a strategy for designing dual mode sensing mechanisms for different analytical purposes based on novel stimuli-responsive materials.
Xia, Ning; Liu, Ke; Zhou, Yingying; Li, Yuanyuan; Yi, Xinyao
2017-01-01
miRNAs have emerged as new biomarkers for the detection of a wide variety of cancers. By employing duplex-specific nuclease for signal amplification and gold nanoparticles (AuNPs) as the carriers of detection probes, a novel electrochemical assay of miRNAs was performed. The method is based on conversion of the well-known colorimetric assay into electrochemical analysis with enhanced sensitivity. DNA capture probes immobilized on the electrode surface and ferrocene (Fc)-labeled DNA detection probes (denoted “Fc-DNA-Fc”) presented in the solution induced the assembly of positively charged AuNPs on the electrode surface through the electrostatic interaction. As a result, a large number of Fc-DNA-Fc molecules were attached on the electrode surface, thus amplifying the electrochemical signal. When duplex-specific nuclease was added to recycle the process of miRNA-initiated digestion of the immobilized DNA probes, Fc-DNA-Fc-induced assembly of AuNPs on the electrode surface could not occur. This resulted in a significant fall in the oxidation current of Fc. The current was found to be inversely proportional to the concentration of miRNAs in the range of 0–25 fM, and a detection limit of 0.1 fM was achieved. Moreover, this work presents a new method for converting colorimetric assays into sensitive electrochemical analyses, and thus would be valuable for design of novel chemical/biosensors. PMID:28761341
Dawan, Phanphruk; Satarpai, Thiphol; Tuchinda, Patoomratana; Shiowatana, Juwadee; Siripinyanond, Atitaya
2017-01-01
A new analytical platform based on the use of thin-layer chromatography (TLC) coupled with paper-based analytical device (PAD) was developed for the determination of total capsaicinoids in chilli samples. This newly developed TLC-PAD is simple and low-cost without any requirement of special instrument or skillful person. The analysis consisted of two steps, i.e., extraction of capsaicinoids from chilli samples by using ethanol as solvent and separation of capsaicinoids by thin-layer chromatography (TLC) and elution of capsaicinoids from the TLC plate with in situ colorimetric detection of capsaicinoids on the PAD. For colorimetric detection, Folin-Ciocalteu reagent was used to detect phenolic functional group of capsaicinoids yielding the blue color. The blue color on the PAD was imaged by a scanner followed by evaluation of its grayscale intensity value by ImageJ program. This newly developed TLC-PAD method provided a linear range from 50 to 1000mgL -1 capsaicinoids with the limit of detection as low as 50mgL -1 capsaicinoids. The proposed method was applied to determine capsaicinoids in dried chilli and seasoning powder samples and the results were in good agreement with those obtained by HPLC method. Copyright © 2016 Elsevier B.V. All rights reserved.
Tee-ngam, Prinjaporn; Nunant, Namthip; Rattanarat, Poomrat; Siangproh, Weena; Chailapakul, Orawon
2013-01-01
Ferulic acid is an important phenolic antioxidant found in or added to diet supplements, beverages, and cosmetic creams. Two designs of paper-based platforms for the fast, simple and inexpensive evaluation of ferulic acid contents in food and pharmaceutical cosmetics were evaluated. The first, a paper-based electrochemical device, was developed for ferulic acid detection in uncomplicated matrix samples and was created by the photolithographic method. The second, a paper-based colorimetric device was preceded by thin layer chromatography (TLC) for the separation and detection of ferulic acid in complex samples using a silica plate stationary phase and an 85:15:1 (v/v/v) chloroform: methanol: formic acid mobile phase. After separation, ferulic acid containing section of the TLC plate was attached onto the patterned paper containing the colorimetric reagent and eluted with ethanol. The resulting color change was photographed and quantitatively converted to intensity. Under the optimal conditions, the limit of detection of ferulic acid was found to be 1 ppm and 7 ppm (S/N = 3) for first and second designs, respectively, with good agreement with the standard HPLC-UV detection method. Therefore, these methods can be used for the simple, rapid, inexpensive and sensitive quantification of ferulic acid in a variety of samples. PMID:24077320
Mount, D L; Nahlen, B L; Patchen, L C; Churchill, F C
1989-01-01
Two field-adapted colorimetric methods for measuring the antimalarial drug chloroquine in urine are described. Both are modifications of the method of Saker and Solomons for screening urine for phencyclidine and other drugs of abuse, using the colour reagent tetrabromophenolphthalein ethyl ester. One method is semiquantitative, detecting the presence of chloroquine (Cq) and its metabolites in urine with a 1 microgram/ml detection limit; it is more sensitive and reliable than the commonly used Dill-Glazko method and is as easy to apply in the field. The second method uses a hand-held, battery-operated filter photometer to quantify Cq and its metabolites with a 2 microgram/ml detection limit and a linear range up to 8 micrograms/ml. The first method was validated in the field using a published quantitative colorimetric method and samples from a malaria study in Nigeria. The second method was validated in the laboratory against high-performance liquid chromatographic results on paired samples from the Nigerian study. Both methods may be used in remote locations where malaria is endemic and no electricity is available.
Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William
2018-04-23
The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.
NASA Astrophysics Data System (ADS)
Yu, Shanshan; Murakami, Yuri; Obi, Takashi; Yamaguchi, Masahiro; Ohyama, Nagaaki
2006-09-01
The article proposes a multispectral image compression scheme using nonlinear spectral transform for better colorimetric and spectral reproducibility. In the method, we show the reduction of colorimetric error under a defined viewing illuminant and also that spectral accuracy can be improved simultaneously using a nonlinear spectral transform called Labplus, which takes into account the nonlinearity of human color vision. Moreover, we show that the addition of diagonal matrices to Labplus can further preserve the spectral accuracy and has a generalized effect of improving the colorimetric accuracy under other viewing illuminants than the defined one. Finally, we discuss the usage of the first-order Markov model to form the analysis vectors for the higher order channels in Labplus to reduce the computational complexity. We implement a multispectral image compression system that integrates Labplus with JPEG2000 for high colorimetric and spectral reproducibility. Experimental results for a 16-band multispectral image show the effectiveness of the proposed scheme.
ERIC Educational Resources Information Center
Wang, Bo; Lin, Zhiqiang; Wang, Min
2015-01-01
Paper-based microfluidic devices (µPAD) are a burgeoning platform of microfluidic analysis technology. The method described herein is for use in undergraduate and high school chemistry laboratories. A simple and convenient µPAD was fabricated by easy patterning of filter paper using a permanent marker pen. The usefulness of the device was…
Li, Bowei; Fu, Longwen; Zhang, Wei; Feng, Weiwei; Chen, Lingxin
2014-04-01
This paper presents a novel paper-based analytical device based on the colorimetric paper assays through its light reflectance. The device is portable, low cost (<20 dollars), and lightweight (only 176 g) that is available to assess the cost-effectiveness and appropriateness of the original health care or on-site detection information. Based on the light reflectance principle, the signal can be obtained directly, stably and user-friendly in our device. We demonstrated the utility and broad applicability of this technique with measurements of different biological and pollution target samples (BSA, glucose, Fe, and nitrite). Moreover, the real samples of Fe (II) and nitrite in the local tap water were successfully analyzed, and compared with the standard UV absorption method, the quantitative results showed good performance, reproducibility, and reliability. This device could provide quantitative information very conveniently and show great potential to broad fields of resource-limited analysis, medical diagnostics, and on-site environmental detection. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Visualizing Capsaicinoids: Colorimetric Analysis of Chili Peppers
ERIC Educational Resources Information Center
Thompson, Robert Q.; Chu, Christopher; Gent, Robin; Gould, Alexandra P.; Rios, Laura; Vertigan, Theresa M.
2012-01-01
A colorimetric method for total capsaicinoids in chili pepper ("Capsicum") fruit is described. The placental material of the pepper, containing 90% of the capsaicinoids, was physically separated from the colored materials in the pericarp and extracted twice with methanol, capturing 85% of the remaining capsaicinoids. The extract, evaporated and…
Chemiluminescent optical fiber immunosensor for the detection of anti-West Nile virus IgG.
Herrmann, Sebastien; Leshem, Boaz; Landes, Shimi; Rager-Zisman, Bracha; Marks, Robert S
2005-03-31
An ELISA-based optical fiber methodology developed for the detection of anti-West Nile virus IgG antibodies in serum was compared to standard colorimetric and chemiluminescent ELISA based on microtiter plates. Colorimetric ELISA was the least sensitive, especially at high titer dilutions. The fiber-optic immunosensor based on the same ELISA immunological rationale was the most sensitive technique.
Colorimetric As (V) detection based on S-layer functionalized gold nanoparticles.
Lakatos, Mathias; Matys, Sabine; Raff, Johannes; Pompe, Wolfgang
2015-11-01
Herein, we present simple and rapid colorimetric and UV/VIS spectroscopic methods for detecting anionic arsenic (V) complexes in aqueous media. The methods exploit the aggregation of S-layer-functionalized spherical gold nanoparticles of sizes between 20 and 50 nm in the presence of arsenic species. The gold nanoparticles were functionalized with oligomers of the S-layer protein of Lysinibacillus sphaericus JG-A12. The aggregation of the nanoparticles results in a color change from burgundy-red for widely dispersed nanoparticles to blue for aggregated nanoparticles. A detailed signal analysis was achieved by measuring the shift of the particle plasmon resonance signal with UV/VIS spectroscopy. To further improve signal sensitivity, the influence of larger nanoparticles was tested. In the case of 50 nm gold nanoparticles, a concentration of the anionic arsenic (V) complex lower than 24 ppb was detectable. Copyright © 2015 Elsevier B.V. All rights reserved.
Telling, G M; Dunnett, P C
1981-10-01
Synopsis A technique is described for the rapid determination of N-nitrosodiethanolamine (NDELA) in shampoos, skin creams and similar products based on aqueous extraction, partition into ethyl acetate and colorimetric determination using the Eisenbrand-Preussman cleavage reaction. Recoveries of NDELA added at levels of 5-100 mug kg(-1) to a range of shampoo and cream types ranged from 90-101%. The limit of determination for the method is 2.5 mug kg(-1). Observations on the application of a thermal energy analyser linked to a gas chromatograph are also reported. Application of the technique to a survey of a wide range of shampoo and skin cream types showed that levels of total N-nitroso compounds were less than 30 mug kg(-1) in < 90% of samples and, in many cases, less than 2.5 mug kg-1.
Hu, Bo; Guo, Jing; Xu, Ying; Wei, Hua; Zhao, Guojie; Guan, Yifu
2017-08-01
Rapid and accurate detection of microRNAs in biological systems is of great importance. Here, we report the development of a visual colorimetric assay which possesses the high amplification capabilities and high selectivity of the rolling circle amplification (RCA) method and the simplicity and convenience of gold nanoparticles used as a signal indicator. The designed padlock probe recognizes the target miRNA and is circularized, and then acts as the template to extend the target miRNA into a long single-stranded nucleotide chain of many tandem repeats of nucleotide sequences. Next, the RCA product is hybridized with oligonucleotides tagged onto gold nanoparticles. This interaction leads to the aggregation of gold nanoparticles, and the color of the system changes from wine red to dark blue according to the abundance of miRNA. A linear correlation between fluorescence and target oligonucleotide content was obtained in the range 0.3-300 pM, along with a detection limit of 0.13 pM (n = 7) and a RSD of 3.9% (30 pM, n = 9). The present approach provides a simple, rapid, and accurate visual colorimetric assay that allows sensitive biodetection and bioanalysis of DNA and RNA nucleotides of interest in biologically important samples. Graphical abstract The colorimetric assay system for analyzing target oligonucleotides.
Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.
Smith, R F; Mather, H M; Ellard, G A
1998-02-01
The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.
Wongniramaikul, Worawit; Limsakul, Wadcharawadee; Choodum, Aree
2018-05-30
A biodegradable colorimetric film was fabricated on the lid of portable tube for in-tube formaldehyde detection. Based on the entrapment of colorimetric reagents within a thin film of tapioca starch, the yellow reaction product was observed with formaldehyde. Intensity of the blue channel from the digital image of yellow product showed a linear relationship in the range of 0-25 mg L -1 with low detection limit of 0.7 ± 0.1 mg L -1 . Inter-day precision of 0.61-3.10%RSD were obtained with less than 4.2% relative error from control samples. The developed method was applied for various food samples in Phuket and formaldehyde concentration range was non-detectable to 1.413 mg kg -1 . The quantified concentrations of formaldehyde in fish and squid samples provided relative errors of -7.7% and +10.8% compared to spectrophotometry. This low cost sensor (∼0.04 USD/test) with digital image colorimetry was thus an effective alternative for formaldehyde detection in food sample. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wang, Yi-Wei; Wang, Meili; Wang, Lixing; Xu, Hui; Tang, Shurong; Yang, Huang-Hao; Zhang, Lan; Song, Hongbo
2017-11-02
In this work, uniformly-dispersed platinum nanoparticles (PtNPs) were synthesized by a simple chemical reduction method, in which citric acid and sodium borohydride acted as a stabilizer and reducer, respectively. An ultrasensitive colorimetric sensor for the facile and rapid detection of Ag⁺ ions was constructed based on the peroxidase mimetic activities of the obtained PtNPs, which can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H₂O₂ to produce colored products. The introduced Ag⁺ would be reduced to Ag⁰ by the capped citric acid, and the deposition of Ag⁰ on the PtNPs surface, can effectively inhibit the peroxidase-mimetic activity of PtNPs. Through measuring the maximum absorption signal of oxidized TMB at 652 nm, ultra-low detection limits (7.8 pM) of Ag⁺ can be reached. In addition to such high sensitivity, the colorimetric assay also displays excellent selectivity for other ions of interest and shows great potential for the detection of Ag⁺ in real water samples.
O'Sullivan, N A; Fallon, R; Carroll, C; Smith, T; Maher, M
2000-02-01
Campylobacter enteritis in humans has been linked to consumption of poultry meat. Surveys show that 30-100% of poultry harbour Campylobacter as normal flora of the digestive tract which indicates a need to identify prevalent organism types in flocks and trace their epidemiology. In this study we describe a Campylobacter genus specific polymerase chain reaction (PCR) assay, amplifying the 16 S-23 S rRNA intergenic spacer region with an internal Campylobacter genus specific DNA probe and species specific probes for Campylobacter jejuni and Campylobacter coli designed for confirmation of the amplified PCR products by Southern blot and colorimetric reverse hybridization assays. The specificity of this assay was established by testing a range of food pathogens. Broiler chicken samples were tested following presumptive positive identification by the Malthus System V analyser (Malthus Instruments, UK). The combined PCR and colorimetric reverse hybridization assay is easy to perform and faster than conventional methods for confirmation and identification of Campylobacter species. Copyright 2000 Academic Press.
NASA Astrophysics Data System (ADS)
Khezri, Somayeh; Bahram, Morteza; Samadi, Naser
2018-01-01
In this paper, we describe a rapid, low-cost and highly sensitive colorimetric method for the detection of isoprenaline, based on 2-amino-5-mercapto-1,3,4-thiadiazol (AMTD) functionalized gold nanoparticles (AMTD-AuNPs) as a sensing element. Hydrogen bonding interaction between isoprenaline and AMTD resulted in the aggregation of AuNPs and a consequent color change of AuNPs from red to blue. The concentration of isoprenaline could be detected with the naked eye or a UV-visible spectrometer. Results showed that the absorbance ratio (A650/A524) was linear with isoprenaline concentrations in the range of 0.2 to 2.6 μM (R = 0.997). The detection limit of this method was 0.08 μM. The proposed method is simple, without using complicated instruments and adding salts for enhancing sensitivity. This probe could be successfully applied to the determination of isoprenaline in human serum samples and urine samples after deproteinization.
Srirangsan, Paveena; Hamada-Sato, Naoko; Kawai, Kiyoshi; Watanabe, Manabu; Suzuki, Toru
2010-12-08
Alkaline phosphatase (ALP), nucleoside phosphorylase (NP), and xanthine oxidase (XOD) were used in a colorimetric method for evaluation of fish freshness based on the Ki value. Two enzyme mixtures, NP-XOD and ALP-NP-XOD, were prepared with a color developing agent, and stabilities of the enzymes were improved by freeze-drying with glass-forming additives, i.e., sucrose and sucrose-gelatin. As a result, a linear relationship was obtained between the Ki values determined by the developed colorimetric method and a conventional high-performance liquid chromatography with a high correlation coefficient of 0.997. All enzyme samples containing the additive(s) were amorphous, and higher enzymes activities were maintained compared to those freeze-dried without an additive. Sucrose-gelatin/enzyme mixtures showed higher glass transition temperature; consequently, the enzymes were better stabilized than the sucrose/enzyme formulations. Using the sucrose-gelatin/enzyme mixture, Ki values of fish meat could be accurately determined even after 6-month storage of the dried enzymes at 40 °C.
Photonic Crystal Structures with Tunable Structure Color as Colorimetric Sensors
Wang, Hui; Zhang, Ke-Qin
2013-01-01
Colorimetric sensing, which transduces environmental changes into visible color changes, provides a simple yet powerful detection mechanism that is well-suited to the development of low-cost and low-power sensors. A new approach in colorimetric sensing exploits the structural color of photonic crystals (PCs) to create environmentally-influenced color-changeable materials. PCs are composed of periodic dielectrics or metallo-dielectric nanostructures that affect the propagation of electromagnetic waves (EM) by defining the allowed and forbidden photonic bands. Simultaneously, an amazing variety of naturally occurring biological systems exhibit iridescent color due to the presence of PC structures throughout multi-dimensional space. In particular, some kinds of the structural colors in living organisms can be reversibly changed in reaction to external stimuli. Based on the lessons learned from natural photonic structures, some specific examples of PCs-based colorimetric sensors are presented in detail to demonstrate their unprecedented potential in practical applications, such as the detections of temperature, pH, ionic species, solvents, vapor, humidity, pressure and biomolecules. The combination of the nanofabrication technique, useful design methodologies inspired by biological systems and colorimetric sensing will lead to substantial developments in low-cost, miniaturized and widely deployable optical sensors. PMID:23539027
Abnous, Khalil; Danesh, Noor Mohammad; Ramezani, Mohammad; Taghdisi, Seyed Mohammad; Emrani, Ahmad Sarreshtehdar
2018-08-22
Herein, a novel colorimetric aptasensor was introduced for detection of cocaine based on the formation of three-way junction pockets on the surfaces of gold nanoparticles (AuNPs) and the catalytic activity of the surfaces of AuNPs. Simplicity and detection of cocaine in a short time (only 35 min) are some of the unique features of the proposed sensing strategy. In the presence of cocaine, triple-fragment aptamer (TFA) forms on the surfaces of AuNPs, leading to a significant decrease of the catalytic activity of AuNPs and the color of samples remains yellow. In the absence of target, TFA does not form on the surfaces of AuNPs and 4-Nitrophenol, as a colorimetric agent, has more access to the surfaces of AuNPs, resulting in the reduction of 4-Nitrophenol and the color of sample changes from yellow to colorless. The sensing strategy showed good specificity, a limit of detection (LOD) of 440 pM and a dynamic range over 2-100 nM. The sensing method was also successfully applied to detect cocaine in spiked human serum samples with recovery of 94.71-98.63%. Copyright © 2018 Elsevier B.V. All rights reserved.
Detection and Spatial Mapping of Mercury Contamination in Water Samples Using a Smart-Phone
2014-01-20
Au NP) and aptamer based colorimetric transmission assay that is implemented in disposable test tubes. With this smart-phone attachment that weighs...detection . colorimetric sensor . gold nanoparticles . aptamers A RTIC LE Terms of Use WEI ET AL. VOL. 8 ’ NO. 2 ’ 1121–1129 ’ 2014 www.acsnano.org 1122...a colorimetric assay utilizing citrate-stabilized plasmonic AuNPs and aptamers (Apt) mixed within disposable test tubes. Due to the shift in the
Wang, Lin; Liu, Zhanmin; Xia, Xueying; Yang, Cuiyun; Huang, Junyi; Wan, Sibao
2017-05-01
Cucumber green mottle mosaic virus (CGMMV)causes a severe mosaic symptom of watermelon and cucumber, and can be transmitted via infected cucumber seeds, leaves and soil. It remains a challenge to detect this virus to prevent its introduction and infection and spread in fields. For this purpose, a simple and sensitive label-free colorimetric detection method for CGMMV has been developed with unmodified gold nanoparticles (AuNPs) as colorimetric probes. The method is based on the finding that the presence of RT-PCR target products of CGMMV and species-specific probes results in color change of AuNPs from red to blue after NaCl induction. Normally, species-specific probes attach to the surface of AuNPs and thereby increasing their resistance to NaCl-induced aggregation. The concentration of sodium, probes in the reaction system and evaluation of specificity and sensitivity of a novel assay, visual detection of Cucumber green mottle mosaic virus using unmodified AuNPs has been carried out with simple preparation of samples in our study. Through this assay, as low as 30pg/μL of CGMMV RNA was thus detected visually, by the naked eye, without the need for any sophisticated, expensive instrumentation and biochemical reagents. The specificity was 100% and exhibited good reproducibility in our assays. The results note that this assay is highly species-specific, simple, low-cost, and visual for easy detection of CGMMV in plant tissues. Therefore, visual assay is a potentially useful tool for middle or small-scales corporations and entry-exit inspection and quarantine bureau to detect CGMMV in cucumber seeds or plant tissues. Copyright © 2017 Elsevier B.V. All rights reserved.
He, Yi; Wang, Li
2017-05-05
Here we report a label-free method for visual colorimetric detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (HTT) explosive based on base-driven sunlight oxidation of silver nanoprisms (AgNPRs). Under natural sunlight illumination, the surface plasmon of AgNPRs is excited, which populates O 2 antibonding orbitals to generate negative-ion state (O 2 - ). The resultant O 2 - with a strong oxidation activity can etch AgNPRs to smaller nanodisks with the aid of NaOH aqueous solution, leading to a blue shift of the absorption peak and color change from blue to pink. However, when HTT is introduced, the resultant O 2 - will be consumed by the nitrite and formaldehyde that are produced from the alkaline hydrolysis of HTT. Under this condition, the etching of AgNPRs does not occur, and the detection solution remains blue. This assay can sensitively detect as low as 1nM HTT, a level which is three orders of magnitude lower than that of gold nanoparticle-based colorimetric assays (2.6μM), and shows linearity in the range of 0.003-3.3μM. The lowest detectable concentration with the naked eye is 0.1μM. Additionally, the present assay exhibits good selectivity, and can be applied in the detection of HTT in natural water and soil samples with recoveries ranging from 90% to 100%. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kopriva, Ivica; Popović Hadžija, Marijana; Hadžija, Mirko; Aralica, Gorana
2016-03-01
Recently, novel data-driven offset-sparsity decomposition (OSD) method was proposed by us to increase colorimetric difference between tissue-structures present in the color microscopic image of stained specimen in histopathology. The OSD method performs additive decomposition of vectorized spectral images into image-adapted offset term and sparse term. Thereby, the sparse term represents an enhanced image. The method was tested on images of the histological slides of human liver stained with hematoxylin and eosin, anti-CD34 monoclonal antibody and Sudan III. Herein, we present further results related to increase of colorimetric difference between tissue structures present in the images of human liver specimens with pancreatic carcinoma metastasis stained with Gomori, CK7, CDX2 and LCA, and with colon carcinoma metastasis stained with Gomori, CK20 and PAN CK. Obtained relative increase of colorimetric difference is in the range [19.36%, 103.94%].
Detection of Carbendazim Residues with a Colorimetric Sensor Based on Gold Nanoparticles
NASA Astrophysics Data System (ADS)
Ma, Y.; Jiang, H.; Shen, C.; Hou, Ch.; Huo, D.; Wu, H.; Yang, M.
2017-07-01
Carbendazim is among the most popular benzimidazole bactericides that are widely used to boost food production, and its residue poses a great threat to human health and the environment. In this paper, we presented a colorimetric sensor based on gold nanoparticles (Au-NPs) for the detection of carbendazim residues. The Au-NPs were stabilized by citric acid synthesized by chloroauric acid and sodium citrate with a diameter of about 13 nm. Upon reaction with carbendazim, the sensor gave a clear color change that could be distinguished with the naked eye. Thus we elaborated a new method for rapid determination of this benzimidazole bactericide. After optimization of the detection conditions, the sensor showed a very good linear relationship with the carbendazim concentrations varying from 10 to 600 ppb with a detection limit down to 3.4 ppb (S/N = 3). These preliminary results demonstrate that the presented sensor is promising for fast carbendazim analysis.
NASA Technical Reports Server (NTRS)
Lipert, Robert J.; Porter, Marc D.; Siperko, Lorraine M.; Gazda, Daniel B.; Rutz, Jeff A.; Schultz, John R.; Carrizales, Stephanie M.; McCoy, J. Torin
2009-01-01
An experimental drinking water monitoring kit for the measurement of iodine and silver(I) was recently delivered to the International Space Station (ISS). The kit is based on Colorimetric Solid Phase Extraction (CSPE) technology, which measures the change in diffuse reflectance of indicator disks following exposure to a water sample. To satisfy additional spacecraft water monitoring requirements, CSPE has now been extended to encompass the measurement of total I (iodine, iodide, and triiodide) through the introduction of an oxidizing agent, which converts iodide and triiodide to iodine, for measurement using the same indicator disks currently being tested on ISS. These disks detect iodine, but are insensitive to iodide and triiodide. We report here the operational considerations, design, and ground-based performance of the CSPE method for total I. The results demonstrate that CSPE technology is poised to meet NASA's total I monitoring requirements.
Wu, Tzu-Heng; Chang, Chia-Chen; Vaillant, Julien; Bruyant, Aurélien; Lin, Chii-Wann
2016-11-15
Smartphone camera based gold nanoparticle colorimetry (SCB-AuNP colorimetry) has shown good potential for point-of-care applications. However, due to the use of a camera as a photo-detector, there are major limitations to this technique such as a low bit resolution (∼8 bits mainstream) and a low data acquisition rate. These issues have limited the ultimate sensitivity of smartphone based colorimetry as well as the possibility to integrate efficiently a more sensitive approach such as detection based on a lock-in amplifier (LIA). In this paper, we improve the metrological performance of the smartphone to overcome existing issues by adding the LIA capability to AuNP sensing. In this work, instead of using the camera as a photo-detector, the audio jack is used as a photo-detector reader and function generator for driving a laser diode in order to achieve a smartphone based digital lock-in amplifier AuNP colorimetric (SBLIA-AuNP colorimetry) system. A full investigation on the SBLIA design, parameters and performance is comprehensively provided. It is found that the SBLIA can reduce most of the noise and provides a detection noise-to-signal ratio down to -63 dB, which is much better than the -49 dB of the state-of-the-art SCB based method. A DNA detection experiment is demonstrated to reveal the efficacy of the proposed metrological method. The results are compared to UV-visible spectrometry, which is the gold standard for colorimetric measurement. Based on our results, the SBLIA-AuNP colorimetric system has a detection limit of 0.77 nM on short strand DNA detection, which is 5.7 times better than the 4.36 nM limit of a commercial UV-visible spectrometer. Judging from the results, we believe that the sensitive SBLIA would be further extended to other optical diagnostic tools in the near future.
Nucleic acid-coupled colorimetric analyte detectors
Charych, Deborah H.; Jonas, Ulrich
2001-01-01
The present invention relates to methods and compositions for the direct detection of analytes and membrane conformational changes through the detection of color changes in biopolymeric materials. In particular, the present invention provide for the direct colorimetric detection of analytes using nucleic acid ligands at surfaces of polydiacetylene liposomes and related molecular layer systems.
A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt
Carol A. Clausen; Vina W. Yang
2011-01-01
Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...
Azomethine H colorimetric method for determining dissolved boron in water
Spencer, R.R.; Erdmann, D.E.
1979-01-01
An automated colorimetric method for determining dissolved boron in water is described. The boron is complexed with azomethine H, which is readily available as the condensation product of H acid (8-amino-1-naphthol-3,6-disulfonic acid) and salicylaldehyde. The absorbance of the yellow complex formed is then measured colorimetrically at 410 nm. Interference effects from other dissolved species are minimized by the addition of diethylenetriaminepentaacetic acid (DTPA); however, iron, zinc, and bicarbonate interfere at concentrations above 400 ??g/L, 2000 ??g/L, and 200 mg/L, respectively. The bicarbonate interference can be eliminated by careful acidification of the sample with concentrated HCl to a pH between 5 and 6. Thirty samples per hour can be routinely analyzed over the range of from 10 to 400 ??g/L, boron.
Wang, Xu; Li, Fang; Cai, Ziqi; Liu, Kaifan; Li, Jing; Zhang, Boyang; He, Jianbo
2018-04-01
In this work, a multilayer-modified paper-based colorimetric sensing platform with improved color uniformity and intensity was developed for the sensitive and selective determination of uric acid and glucose with smartphone as signal readout. In detail, chitosan, different kinds of chromogenic reagents, and horseradish peroxidase (HRP) combined with a specific oxidase, e.g., uricase or glucose oxidase (GOD), were immoblized onto the paper substrate to form a multilayer-modified test paper. Hydrogen peroxide produced by the oxidases (uricase or GOD) reacts with the substrates (uric acid or glucose), and could oxidize the co-immoblized chromogenic reagents to form colored products with HRP as catalyst. A simple strategy by placing the test paper on top of a light-emitting diode lamp was adopted to efficiently prevent influence from the external light. The color images were recorded by the smartphone camera, and then the gray values of the color images were calculated for quantitative analysis. The developed method provided a wide linear response from 0.01 to 1.0 mM for uric acid detection and from 0.02 to 4.0 mM for glucose detection, with a limit of detection (LOD) as low as 0.003 and 0.014 mM, respectively, which was much lower than for previously reported paper-based colorimetric assays. The proposed assays were successfully applied to uric acid and glucose detection in real serum samples. Furthermore, the enhanced analytical performance of the proposed method allowed the non-invasive detection of glucose levels in tear samples, which holds great potential for point-of-care analysis. Graphical abstract ᅟ.
Amini, Bahram; Kamali, Mehdi; Salouti, Mojtaba; Yaghmaei, Parichehreh
2018-06-15
Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanoparticles (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50ngmL -1 with the limit detection of 9.899ngmL -1 . Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 10 3 to 10 8 CFUmL -1 in real samples with a detection limit of 320CFUmL -1 . Copyright © 2018 Elsevier B.V. All rights reserved.
De Silva, Veronica; Oldham, Charlie D; May, Sheldon W
2010-09-01
Phenylketonuria (PKU) is an autosomal recessive disorder caused by an impaired conversion of L-phenylalanine (Phe) to L-tyrosine, typically resulting from a deficiency in activity of a hepatic and renal enzyme L-phenylalanine hydroxylase. The disease is characterized by an increased concentration of Phe and its metabolites in body fluids. A modified assay based on an enzymatic-colorimetric methodology was developed for measuring blood Phe levels in PKU patients; this method is designed for use with undeproteinized samples and avoids the use of solvents or amphiphilic agents. Thus, the method could be suitable for incorporation into a simple home-monitoring device. We report here on a comparison of blood Phe concentrations in PKU patients measured in undeproteinized plasma using this enzyme colorimetric assay (ECA), with values determined by amino acid analysis (AAA) of deproteinized samples, and HPLC and tandem mass spectrometry (MS/MS) analyses of dried blood spot (DBS) eluates. Pearson correlation coefficients of 0.951, 0.976 and 0.988 were obtained when AAA-measured Phe concentrations were compared with the ECA-, HPLC- or MS/MS-measured values, respectively. A Bland-Altman analysis revealed that mean Phe concentrations determined using AAA were on average 65 μmol/L lower than values measured by our ECA. These results may be the result of minimizing the manipulations performed on the patient sample compared with AAA, HPLC, and MS/MS methods, which involve plasma deproteinization or DBS elution and derivatization. The results reported here confirm that Phe concentrations determined by our ECA method are comparable to those determined by other widely used methods for a broad range of plasma Phe concentrations.
Chen, Xi; Chen, Jin; Wang, Fubin; Xiang, Xia; Luo, Ming; Ji, Xinghu; He, Zhike
2012-05-15
In this work, we first employ a drying method combining with the bienzyme colorimetric detection of glucose and uric acid on microfluidic paper-based analysis devices (μPADs). The channels of 3D μPADs are also designed by us to get better results. The color results are recorded by both Gel Documentation systems and a common camera. By using Gel Documentation systems, the limits of detection (LOD) of glucose and uric acid are 3.81 × 10(-5)M and 4.31 × 10(-5)M, respectively one order of magnitude lower than that of the reported methods on μPADs. By using a common camera, the limits of detection (LOD) of glucose and uric acid are 2.13 × 10(-4)M and 2.87 × 10(-4)M, respectively. Furthermore, the effects of detection conditions have been investigated and discussed comprehensively. Human serum samples are detected with satisfactory results, which are comparable with the clinical testing results. A low-cost, simple and rapid colorimetric method for the simultaneous detection of glucose and uric acid on the μPADs has been developed with enhanced sensitivity. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pourreza, Nahid; Lotfizadeh, Neda; Golmohammadi, Hamed
2018-03-01
In this research, a new colorimetric method for the determination of oxalate using curcumin nanoparticles (CURNs) in the presence Fe (III) is introduced. The method is based on the inhibitory effect of oxalate ion on the reaction of (CURNs) with Fe (III) in acidic media. This reaction was monitored by measuring the increase in absorbance of CURNs-Fe3 + complex in the presence of oxalate ion at 427 nm. The effect of different parameters such as the pH of the sample solution, concentration of Fe (III), concentration of CURNs and the reaction time was examined and optimized. Under optimum experimental conditions, the absorption intensity was linear with the concentration of oxalate in the range of 0.15 to 1.70 μg mL- 1. The limit of detection (LOD) was 0.077 μg mL- 1 and the relative standard deviations (RSD) for 8 replicate measurements of 0.40 and 1.05 μg mL- 1 of oxalate were 4.20% and 2.74%, respectively. The developed method was successfully employed to the determination of oxalate in water, food and urine samples with satisfactory results.
Aptamer-mediated colorimetric method for rapid and sensitive detection of chloramphenicol in food.
Yan, Chao; Zhang, Jing; Yao, Li; Xue, Feng; Lu, Jianfeng; Li, Baoguang; Chen, Wei
2018-09-15
We report an aptamer-mediated colorimetric method for sensitive detection of chloramphenicol (CAP). The aptamer of CAP is immobilized by the hybridization with pre-immobilized capture probe in the microtiter plate. The horseradish peroxidase (HRP) is covalently attached to the aptamer by the biotin-streptavidin system for signal production. CAP will preferably bind with aptamer due to the high binding affinity, which attributes to the release of aptamer and HRP and thus, affects the optical signal intensity. Quantitative determination of CAP is successfully achieved in the wide range from 0.001 to 1000 ng/mL with detection limit of 0.0031 ng/mL, which is more sensitive than traditional immunoassays. This method is further validated by measuring the recovery of CAP spiked in two different food matrices (honey and fish). The aptamer-mediated colorimetric method can be a useful protocol for rapid and sensitive screening of CAP, and may be used as an alternative means for traditional immunoassays. Copyright © 2018 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Phosphatidate phosphatase (3-sn-phosphatidate phosphohydrolase, EC 3.1.3.4), which is also known as PAP, catalyzes the dephosphorylation of phosphatidate (PtdOH) to form diacylglycerol (DAG) and inorganic phosphate. In eukaryotes, PAP driven reaction is the committed step in the synthesis of triacyl...
False positive acetaminophen concentrations in patients with liver injury.
Polson, Julie; Wians, Frank H; Orsulak, Paul; Fuller, Dwain; Murray, Natalie G; Koff, Jonathan M; Khan, Adil I; Balko, Jody A; Hynan, Linda S; Lee, William M
2008-05-01
Acetaminophen toxicity is the most common form of acute liver failure in the U.S. After acetaminophen overdoses, quantitation of plasma acetaminophen can aid in predicting severity of injury. However, recent case reports have suggested that acetaminophen concentrations may be falsely increased in the presence of hyperbilirubinemia. We tested sera obtained from 43 patients with acute liver failure, mostly unrelated to acetaminophen, utilizing 6 different acetaminophen quantitation systems to determine the significance of this effect. In 36 of the 43 samples with bilirubin concentrations ranging from 1.0-61.5 mg/dl no acetaminophen was detectable by gas chromatography-mass spectroscopy. These 36 samples were then utilized to test the performance characteristics of 2 immunoassay and 4 enzymatic-colorimetric methods. Three of four colorimetric methods demonstrated 'detectable' values for acetaminophen in from 4 to 27 of the 36 negative samples, low concentration positive values being observed when serum bilirubin concentrations exceeded 10 mg/dl. By contrast, the 2 immunoassay methods (EMIT, FPIA) were virtually unaffected. The false positive values obtained were, in general, proportional to the quantity of bilirubin in the sample. However, prepared samples of normal human serum with added bilirubin showed a dose-response curve for only one of the 4 colorimetric assays. False positive acetaminophen tests may result when enzymatic-colorimetric assays are used, most commonly with bilirubin concentrations >10 mg/dl, leading to potential clinical errors in this setting. Bilirubin (or possibly other substances in acute liver failure sera) appears to affect the reliable measurement of acetaminophen, particularly with enzymatic-colorimetric assays.
Huang, Zhenzhen; Wang, Haonan; Yang, Wensheng
2015-05-06
In this work, a facile colorimetric method is developed for quantitative detection of human serum albumin (HSA) based on the antiaggregation effect of gold nanoparticles (Au NPs) in the presence of HSA. The citrate-capped Au NPs undergo a color change from red to blue when melamine is added as a cross-linker to induce the aggregation of the NPs. Such an aggregation is efficiently suppressed upon the adsorption of HSA on the particle surface. This method provides the advantages of simplicity and cost-efficiency for quantitative detection of HSA with a detection limit of ∼1.4 nM by monitoring the colorimetric changes of the Au NPs with UV-vis spectroscopy. In addition, this approach shows good selectivity for HSA over various amino acids, peptides, and proteins and is qualified for detection of HSA in a biological sample. Such an antiaggregation effect can be further extended to fabricate an INHIBIT logic gate by using HSA and melamine as inputs and the color changes of Au NPs as outputs, which may have application potentials in point-of-care medical diagnosis.
Colorimetric detection of cholesterol based on enzyme modified gold nanoparticles
NASA Astrophysics Data System (ADS)
Nirala, Narsingh R.; Saxena, Preeti S.; Srivastava, Anchal
2018-02-01
We develop a simple colorimetric method for determination of free cholesterol in aqueous solution based on functionalized gold nanoparticles with cholesterol oxidase. Functionalized gold nanoparticles interact with free cholesterol to produce H2O2 in proportion to the level of cholesterol visually is being detected. The quenching in optical properties and agglomeration of functionalized gold nanoparticles play a key role in cholesterol sensing due to the electron accepting property of H2O2. While the lower ranges of cholesterol (lower detection limit i.e. 0.2 mg/dL) can be effectively detected using fluorescence study, the absorption study attests evident visual color change which becomes effective for detection of higher ranges of cholesterol (lower detection limit i.e. 19 mg/dL). The shades of red gradually change to blue/purple as the level of cholesterol detected (as evident at 100 mg/dL) using unaided eye without the use of expensive instruments. The potential of the proposed method to be applied in the field is shown by the proposed cholesterol measuring color wheel.
Lesniewski, Adam; Los, Marcin; Jonsson-Niedziółka, Martin; Krajewska, Anna; Szot, Katarzyna; Los, Joanna M; Niedziolka-Jonsson, Joanna
2014-04-16
Herein, we report a colorimetric immunosensor for T7 bacteriophage based on gold nanoparticles modified with covalently bonded anti-T7 antibodies. The new immunosensor allows for a fast, simple, and selective detection of T7 virus. T7 virions form immunological complexes with the antibody modified gold nanoparticles which causes them to aggregate. The aggregation can be observed with the naked eye as a color change from red to purple, as well as with a UV-vis spectrophotometer. The aggregate formation was confirmed with SEM imaging. Sensor selectivity against the M13 bacteriophage was demonstrated. The limit of detection (LOD) is 1.08 × 10(10) PFU/mL (18 pM) T7. The new method was compared with a traditional plaque test. In contrast to biological tests the colorimetric method allows for detection of all T7 phages, not only those biologically active. This includes phage ghosts and fragments of virions. T7 virus has been chosen as a model organism for adenoviruses. The described method has several advantages over the traditional ones. It is much faster than a standard plaque test. It is more robust since no bacteria-virus interactions are utilized in the detection process. Since antibodies are available for a large variety of pathogenic viruses, the described concept is very flexible and can be adapted to detect many different viruses, not only bacteriophages. Contrary to the classical immunoassays, it is a one-step detection method, and no additional amplification, e.g., enzymatic, is needed to read the result.
Shinohara, Naohide; Kajiwara, Tomohisa; Ohnishi, Masato; Kodama, Kenichi; Yanagisawa, Yukio
2008-06-15
A coin-sized passive emission colorimetric sensor (PECS) based on an enzymatic reaction and a portable reflectance photometry device were developed to determine the emission rates of formaldehyde from building materials and other materials found indoors in only 30 minutes on-site. The color change of the PECS linearly correlated to the concentration of formaldehyde aqueous solutions up to 28 microg/mL. The correlation between the emission rates measured by using the PECS and those measured by using a desiccator method or by using a chamber method was fitted with a linear function and a power function, and the determination coefficients were more than 0.98. The reproducible results indicate that the emission rates could be obtained with the correlation equations from the data measured by using the PECS and the portable reflectance photometry device. Limits of detection (LODs) were 0.051 mg/L for the desiccator method and 3.1 microg/m2/h for the chamber method. Thus, it was confirmed that the emission rates of formaldehyde from the building materials classified as F four-star (< 0.3 mg/L (desiccator method) or < 5.0 microg/m2/h (chamber method)), based on Japanese Industrial Standards (JIS), could be measured with the PECS. The measurement with PECS was confirmed to be precise (RSD < 10%). Other chemicals emitted from indoor materials, such as methanol, ethanol, acetone, toluene, and xylene, interfered little with the measurement of formaldehyde emission rates by using the PECS.
Catucci, Gianluca; Polignano, Isabelle; Cusumano, Debora; Medana, Claudio; Gilardi, Gianfranco; Sadeghi, Sheila J
2017-04-01
Human hepatic flavin-containing monooxygenase 3 is a phase I drug-metabolizing enzyme that is responsible for the oxidation of a variety of drugs and xenobiotics. This work reports on a high throughput rapid colorimetric assay for the screening of substrates or inhibitors of this enzyme. The method is based on the competition of two substrates for access to the active site of hFMO3 whereby the enzymatic product of the first drug converts nitro-5-thiobenzoate (TNB, yellow) to 5,5'-dithiobis (2-nitrobenzoate) (DTNB, colourless). Upon addition of a competing substrate, the amount of detected DNTB is decreased. The assay is validated testing three known substrates of hFMO3, namely benzydamine, tozasertib and tamoxifen. The latter drugs resulted in 41%-55% inhibition. In addition, two other drugs also classified as doping drugs, selegiline and clomiphene, were selected based on their chemical structure similarity to known substrates of hFMO3. These drugs showed 21% and 60% inhibition in the colorimetric assay and therefore were proven to be hFMO3 substrates. LC-MS was used to confirm their N-oxide products. Further characterisation of these newly identified hFMO3 substrates was performed determining their K m and k cat values that resulted to be 314 μM and 1.4 min -1 for selegiline and, 18 μM and 0.1 min -1 for clomiphene. This method paves the way for a rapid automated high throughput screening of nitrogen-containing compounds as substrates/inhibitors of hFMO3. Copyright © 2017 Elsevier Inc. All rights reserved.
Colorimetric detection of UV light-induced single-strand DNA breaks using gold nanoparticles.
Kim, Joong Hyun; Chung, Chan Ho; Chung, Bong Hyun
2013-02-21
We developed a colorimetric method to specifically detect single-strand DNA breaks using gold nanoparticles. In our assay, broken DNA cannot stabilize gold nanoparticles to prevent salt-induced aggregation as good as intact DNA can, and this effect can be easily observed with the naked eye as a red-to-purple color change.
Üzer, Ayşem; Yalçın, Uğur; Can, Ziya; Erçağ, Erol; Apak, Reşat
2017-12-01
Pentaerythritol tetranitrate (PETN) is the nitrate ester of pentaerythritol, used as an energetic and filling material for military and civilian purposes and rarely for terrorist actions. As there is no reliable nano-colorimetric method for PETN assay, we developed an indirect method based on the determination of nitrite, obtained by reduction of nitrate derived from the alkaline hydrolysis of PETN with H 2 O 2 . We colorimetrically determined the final product, nitrite, by both conventional Griess reaction and a recently developed gold nanoparticle-4-aminothiophenol-N-(1-naphthyl)-ethylenediamine (AuNP-4-ATP+NED) method. Nitramines (RDX and HMX), if present, could be degraded by alkaline hydrolysis, without affecting PETN. The analytical performance characteristics of the developed assays as molar absorptivity (ε), limits of detection (LOD) and quantification (LOQ) were: ɛ=1.06×10 5 L mol -1 cm -1 , LOD=0.03mgL -1 and LOQ=0.11mgL -1 for indirect Griess method; ɛ=1.9×10 4 Lmol -1 cm -1 ; LOD=0.12mgL -1 and LOQ=0.4mgL -1 for AuNP-4-ATP+NED method. Both methods were applied to a 1:1 (w/w) mixture of PETN and TNT (corresponding to the composition of military explosive 'Pentolite'). In order to eliminate the interference from TNT, the Meisenheimer anion of TNT formed in alkaline medium was retained on a strongly basic anion exchange resin column. As PETN had a very low solubility in water, common soil ions could be eliminated by prewashing the sample with water, or in acetone-water mixtures, Ca 2+ , K + , Cl - , SO 4 2- , and NO 3 - could be tolerated at equal (1:1) mass ratios. Soil nitrates and nitrites, at a mass ratio of 50:1, could be separated from PETN with the aid of their insolubilities in acetone and of their retention affinity toward a strongly basic anion-exchange resin. The developed method was statistically validated against a reference GC-MS method. Copyright © 2017 Elsevier B.V. All rights reserved.
Nzelu, Chukwunonso O; Gomez, Eduardo A; Cáceres, Abraham G; Sakurai, Tatsuya; Martini-Robles, Luiggi; Uezato, Hiroshi; Mimori, Tatsuyuki; Katakura, Ken; Hashiguchi, Yoshihisa; Kato, Hirotomo
2014-04-01
Entomological monitoring of Leishmania infection in leishmaniasis endemic areas offers epidemiologic advantages for predicting the risk and expansion of the disease, as well as evaluation of the effectiveness of control programs. In this study, we developed a highly sensitive loop-mediated isothermal amplification (LAMP) method for the mass screening of sand flies for Leishmania infection based on the 18S rRNA gene. The LAMP technique could detect 0.01 parasites, which was more sensitive than classical PCR. The method was robust and could amplify the target DNA within 1h from a crude sand fly template without DNA purification. Amplicon detection could be accomplished by the newly developed colorimetric malachite green (MG)--mediated naked eye visualization. Pre-addition of MG to the LAMP reaction solution did not inhibit amplification efficiency. The field applicability of the colorimetric MG-based LAMP assay was demonstrated with 397 field-caught samples from the endemic areas of Ecuador and eight positive sand flies were detected. The robustness, superior sensitivity, and ability to produce better visual discriminatory reaction products than existing LAMP fluorescence and turbidity assays indicated the field potential usefulness of this new method for surveillance and epidemiological studies of leishmaniasis in developing countries. Copyright © 2013 Elsevier B.V. All rights reserved.
[A study of biomechanical method for urine test based on color difference estimation].
Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun
2008-02-01
The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.
Lou, Tingting; Chen, Lingxin; Chen, Zhaopeng; Wang, Yunqing; Chen, Ling; Li, Jinhua
2011-11-01
A colorimetric, label-free, and nonaggregation-based silver coated gold nanoparticles (Ag/Au NPs) probe has been developed for detection of trace Cu(2+) in aqueous solution, based on the fact that Cu(2+) can accelerate the leaching rate of Ag/Au NPs by thiosulfate (S(2)O(3)(2-)). The leaching of Ag/Au NPs would lead to dramatic decrease in the surface plasmon resonance (SPR) absorption as the size of Ag/Au NPs decreased. This colorimetric strategy based on size-dependence of nanoparticles during their leaching process provided a highly sensitive (1.0 nM) and selective detection toward Cu(2+), with a wide linear detection range (5-800 nM) over nearly 3 orders of magnitude. The cost-effective probe allows rapid and sensitive detection of trace Cu(2+) ions in water samples, indicating its potential applicability for the determination of copper in real samples.
Li, Xiuyan; Cheng, Ruojie; Shi, Huijie; Tang, Bo; Xiao, Hanshuang; Zhao, Guohua
2016-03-05
A simple and highly sensitive aptamer-based colorimetric sensor was developed for selective detection of Microcystin-LR (MC-LR). The aptamer (ABA) was employed as recognition element which could bind MC-LR with high-affinity, while gold nanoparticles (AuNPs) worked as sensing materials whose plasma resonance absorption peaks red shifted upon binding of the targets at a high concentration of sodium chloride. With the addition of MC-LR, the random coil aptamer adsorbed on Au NPs altered into regulated structure to form MC-LR-aptamer complexes and broke away from the surface of Au NPs, leading to the aggregation of AuNPs, and the color converted from red to blue due to the interparticle plasmon coupling. Results showed that our aptamer-based colorimetric sensor exhibited rapid and sensitive detection performance for MC-LR with linear range from 0.5 nM to 7.5 μM and the detection limit reached 0.37 nM. Meanwhile, the pollutants usually coexisting with MC-LR in pollutant water samples had not demonstrated disturbance for detecting of MC-LR. The mechanism was also proposed suggesting that high affinity interaction between aptamer and MC-LR significantly enhanced the sensitivity and selectivity for MC-LR detection. Besides, the established method was utilized in analyzing real water samples and splendid sensitivity and selectivity were obtained as well. Copyright © 2015 Elsevier B.V. All rights reserved.
2014-01-01
Background The quality of routine indoor residual spraying (IRS) operations is rarely assessed because of the limited choice of methods available for quantifying insecticide content in the field. This study, therefore, evaluated a user-friendly, rapid colorimetric assay for detecting insecticide content after routine IRS operations were conducted. Methods This study was conducted in Tafea Province, Vanuatu. Routine IRS was conducted with lambda cyhalothrin. Two methods were used to quantify the IRS activities: 1) pre-spray application of small felt pads and 2) post-spray removal of insecticide with adhesive. The insecticide content was quantified using a colorimetric assay (Insecticide Quantification Kit [IQK]), which involved exposing each sample to the test reagents for 15 mins. The concentration of insecticide was indicated by the depth of red colour. Results The IQK proved simple to perform in the field and results could be immediately interpreted by the programme staff. The insecticide content was successfully sampled by attaching felt pads to the house walls prior to spraying. The IRS operation was well conducted, with 83% of houses being sprayed at the target dose (20 – 30 mg AI/m2). The average reading across all houses was 24.4 ± 1.5 mg AI/m2. The results from the felt pads applied pre-spray were used as a base to compare methods for sampling insecticide from walls post-spray. The adhesive of Sellotape did not collect adequate samples. However, the adhesive of the felt pads provided accurate samples of the insecticide content on walls. Conclusion The IQK colorimetric assay proved to be a useful tool that was simple to use under realistic field conditions. The assay provided rapid information on IRS spray dynamics and spray team performance, facilitating timely decision making and reporting for programme managers. The IQK colorimetric assay will have direct applications for routine quality control in malaria control programmes globally and has the potential to improve the efficacy of vector control operations. PMID:24885084
Baker, Matthew S; Phillips, Scott T
2012-05-14
This article describes a small molecule reagent that is capable of detecting fluoride down to 0.12 mM (2.3 ppm) in water. The reagent reveals this level of fluoride through a novel autoinductive signal amplification reaction that produces an unambiguous colorimetric readout.
Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.
Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S
2017-12-19
In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.
Phage & phosphatase: a novel phage-based probe for rapid, multi-platform detection of bacteria.
Alcaine, S D; Pacitto, D; Sela, D A; Nugen, S R
2015-11-21
Genetic engineering of bacteriophages allows for the development of rapid, highly specific, and easily manufactured probes for the detection of bacterial pathogens. A challenge for novel probes is the ease of their adoption in real world laboratories. We have engineered the bacteriophage T7, which targets Escherichia coli, to carry the alkaline phosphatase gene, phoA. This inclusion results in phoA overexpression following phage infection of E. coli. Alkaline phosphatase is commonly used in a wide range of diagnostics, and thus a signal produced by our phage-based probe could be detected using common laboratory equipment. Our work demonstrates the successful: (i) modification of T7 phage to carry phoA; (ii) overexpression of alkaline phosphatase in E. coli; and (iii) detection of this T7-induced alkaline phosphatase activity using commercially available colorimetric and chemilumiscent methods. Furthermore, we demonstrate the application of our phage-based probe to rapidly detect low levels of bacteria and discern the antibiotic resistance of E. coli isolates. Using our bioengineered phage-based probe we were able to detect 10(3) CFU per mL of E. coli in 6 hours using a chemiluminescent substrate and 10(4) CFU per mL within 7.5 hours using a colorimetric substrate. We also show the application of this phage-based probe for antibiotic resistance testing. We were able to determine whether an E. coli isolate was resistant to ampicillin within 4.5 hours using chemiluminescent substrate and within 6 hours using a colorimetric substrate. This phage-based scheme could be readily adopted in labs without significant capital investments and can be translated to other phage-bacteria pairs for further detection.
Ghorai, Anupam; Mondal, Jahangir; Chandra, Rukmani; Patra, Goutam K
2015-08-07
A reversible fluorescent-colorimetric imino-pyridyl bis-Schiff base receptor (N(1)E,N(4)E)-N(1),N(4)-bis(pyridine-4-ylmethylene)benzene-1,4-diamine for the detection of both Al(3+) and HSO3(-) in aqueous medium has been developed. Receptor exhibits an excellent selective fluorescent-colorimetric response toward Al(3+). The sensitivity of the fluorescent based assay (0.903 μM) for Al(3+) is far below the limit recommended in the World Health Organization (WHO) guidelines for drinking water (7.41 μM). From (1)H NMR data, the Job plot and the ESI-MS spectrum, 1 : 2 stoichiometric complexation between and Al(3+) has been established. Receptor shows remarkable detection ability in a wide pH range of 4-11 and was successfully utilised in the determination of Al(3+) in aqueous solution of bovine serum albumin protein, and of HSO3(-) in real food samples. Moreover, shows a highly selective colorimetric response to HSO3(-) by changing its colour from yellow to colorless immediately without any interference from other anions.
Wang, Yanying; Liu, Yaqin; Ding, Fang; Zhu, Xiaoyan; Yang, Li; Zou, Ping; Rao, Hanbing; Zhao, Qingbiao; Wang, Xianxiang
2018-06-07
In this study, we developed a simple colorimetric approach to detect glutathione (GSH). The proposed approach is based on the ability of CuS-PDA-Au composite material to catalytically oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to ox-TMB to induce a blue color with an absorption peak centered at 652 nm. However, the introduction of GSH can result in a decrease in oxidized TMB; similarly, it can combine with Au nanoparticles (Au NPs) on the surface of CuS-PDA-Au composite material. Both approaches can result in a fading blue color and a reduction of the absorbance at 652 nm. Based on this above, we proposed a technique to detect GSH quantitatively and qualitatively through UV-Vis spectroscopy and naked eye, respectively. This approach demonstrates a low detection limit of 0.42 μM with a broad detection range of 5 × 10 -7 -1 × 10 -4 M with the assistance of UV-Vis spectroscopy. More importantly, this approach is convenient and rapid. This method was successfully applied to GSH detection in human serum and cell lines. Graphical abstract A colorimetric approach has been developed by exploiting the peroxidase-like activity of CuS-polydopamine-Au composite for sensitive glutathione detection.
ERIC Educational Resources Information Center
Fenk, Christopher J.; Kaufman, Nathan; Gerbig, Donald G., Jr.
2007-01-01
A new, fast and effective colorimetric analysis of the artificial sweetener aspartame is presented for application in undergraduate laboratory courses. This new method incorporates the use of a modified biuret reagent for selective detection and analysis of aspartame in aqueous solutions. The modified reagent is less caustic than the traditional…
Meloni, Domenico; Spina, Antonio; Satta, Gianluca; Chessa, Vittorio
2016-06-25
In recent years, besides the consumption of fresh sea urchin specimens, the demand of minimally-processed roe has grown considerably. This product has made frequent consumption in restaurants possible and frauds are becoming widespread with the partial replacement of sea urchin roe with surrogates that are similar in colour. One of the main factors that determines the quality of the roe is its colour and small differences in colour scale cannot be easily discerned by the consumers. In this study we have applied a rapid colorimetric method for reveal the fraudulent partial substitution of semi-solid sea urchin roe with liquid egg yolk. Objective assessment of whiteness (L*), redness (a*), yellowness (b*), hue (h*), and chroma (C*) was carried out with a digital spectrophotometer using the CIE L*a*b* colour measurement system. The colorimetric method highlighted statistically significant differences among sea urchin roe and liquid egg yolk that could be easily discerned quantitatively.
Gold nanoparticles mediated colorimetric assay for HIV-Tat protein detection
NASA Astrophysics Data System (ADS)
Hashwan, Saeed S. Ba; Ruslinda, A. Rahim; Fatin, M. F.; Gopinath, Subash C. B.; Thivina, V.; Tony, V. C. S.; Arshad, M. K. Md.; Hashim, U.
2016-07-01
Gold-nanoparticle (AuNP) based colorimetric assays have been formulated for different biomolecular interactions. With this assay the probe such as antibody immobilized on the Au surface and in the presence of appropriate binding partner (antigen), will interact with each other on the Au surface. By following this strategy, herein we formulated a detection system with two anti-HIV-Tat antibodies, Mono (McAb) - and polyclonal (PcAb) by immobilizing them independently with different AuNPs. Under this condition, these two antibodies are under dispersed condition, and in the presence of HIV-Tat antigen, these molecules will be connected and forms the aggregation of AuNPs. This strategy yield rapid results, can be monitored by the spectral changes in UV-Vis spectrophotometry. Experiments were performed with two different methods using two anti-HIV-Tats monoclonal and one Polyclonal antibody against the antigen HIV-Tat. Between these methods conjugation of HIV-Tat and McAb on the AuNP followed by addition of PcAb yielded better results.
"Dip-and-read" paper-based analytical devices using distance-based detection with color screening.
Yamada, Kentaro; Citterio, Daniel; Henry, Charles S
2018-05-15
An improved paper-based analytical device (PAD) using color screening to enhance device performance is described. Current detection methods for PADs relying on the distance-based signalling motif can be slow due to the assay time being limited by capillary flow rates that wick fluid through the detection zone. For traditional distance-based detection motifs, analysis can take up to 45 min for a channel length of 5 cm. By using a color screening method, quantification with a distance-based PAD can be achieved in minutes through a "dip-and-read" approach. A colorimetric indicator line deposited onto a paper substrate using inkjet-printing undergoes a concentration-dependent colorimetric response for a given analyte. This color intensity-based response has been converted to a distance-based signal by overlaying a color filter with a continuous color intensity gradient matching the color of the developed indicator line. As a proof-of-concept, Ni quantification in welding fume was performed as a model assay. The results of multiple independent user testing gave mean absolute percentage error and average relative standard deviations of 10.5% and 11.2% respectively, which were an improvement over analysis based on simple visual color comparison with a read guide (12.2%, 14.9%). In addition to the analytical performance comparison, an interference study and a shelf life investigation were performed to further demonstrate practical utility. The developed system demonstrates an alternative detection approach for distance-based PADs enabling fast (∼10 min), quantitative, and straightforward assays.
Xiao, Wei; Xiao, Meng; Fu, Qiangqiang; Yu, Shiting; Shen, Haicong; Bian, Hongfen; Tang, Yong
2016-11-08
The detection of environmental mercury (Hg) contamination requires complex and expensive instruments and professional technicians. We present a simple, sensitive, and portable Hg 2+ detection system based on a smartphone and colorimetric aptamer nanosensor. A smartphone equipped with a light meter app was used to detect, record, and process signals from a smartphone-based microwell reader (MR S-phone), which is composed of a simple light source and a miniaturized assay platform. The colorimetric readout of the aptamer nanosensor is based on a specific interaction between the selected aptamer and Hg 2+ , which leads to a color change in the reaction solution due to an aggregation of gold nanoparticles (AuNPs). The MR S-phone-based AuNPs-aptamer colorimetric sensor system could reliably detect Hg 2+ in both tap water and Pearl River water samples and produced a linear colorimetric readout of Hg 2+ concentration in the range of 1 ng/mL-32 ng/mL with a correlation of 0.991, and a limit of detection (LOD) of 0.28 ng/mL for Hg 2+ . The detection could be quickly completed in only 20 min. Our novel mercury detection assay is simple, rapid, and sensitive, and it provides new strategies for the on-site detection of mercury contamination in any environment.
Xiao, Wei; Xiao, Meng; Fu, Qiangqiang; Yu, Shiting; Shen, Haicong; Bian, Hongfen; Tang, Yong
2016-01-01
The detection of environmental mercury (Hg) contamination requires complex and expensive instruments and professional technicians. We present a simple, sensitive, and portable Hg2+ detection system based on a smartphone and colorimetric aptamer nanosensor. A smartphone equipped with a light meter app was used to detect, record, and process signals from a smartphone-based microwell reader (MR S-phone), which is composed of a simple light source and a miniaturized assay platform. The colorimetric readout of the aptamer nanosensor is based on a specific interaction between the selected aptamer and Hg2+, which leads to a color change in the reaction solution due to an aggregation of gold nanoparticles (AuNPs). The MR S-phone-based AuNPs-aptamer colorimetric sensor system could reliably detect Hg2+ in both tap water and Pearl River water samples and produced a linear colorimetric readout of Hg2+ concentration in the range of 1 ng/mL–32 ng/mL with a correlation of 0.991, and a limit of detection (LOD) of 0.28 ng/mL for Hg2+. The detection could be quickly completed in only 20 min. Our novel mercury detection assay is simple, rapid, and sensitive, and it provides new strategies for the on-site detection of mercury contamination in any environment. PMID:27834794
Simple colorimetric detection of doxycycline and oxytetracycline using unmodified gold nanoparticles
NASA Astrophysics Data System (ADS)
Li, Jie; Fan, Shumin; Li, Zhigang; Xie, Yuanzhe; Wang, Rui; Ge, Baoyu; Wu, Jing; Wang, Ruiyong
2014-08-01
The interaction between tetracycline antibiotics and gold nanoparticles was studied. With citrate-coated gold nanoparticles as colorimetric probe, a simple and rapid detection method for doxycycline and oxytetracycline has been developed. This method relies on the distance-dependent optical properties of gold nanoparticles. In weakly acidic buffer medium, doxycycline and oxytetracycline could rapidly induce the aggregation of gold nanoparticles, resulting in red-to-blue (or purple) colour change. The experimental parameters were optimized with regard to pH, the concentration of the gold nanoparticles and the reaction time. Under optimal experimental conditions, the linear range of the colorimetric sensor for doxycycline/oxytetracycline was 0.06-0.66 and 0.59-8.85 μg mL-1, respectively. The corresponding limit of detection for doxycycline and oxytetracycline was 0.0086 and 0.0838 μg mL-1, respectively. This assay was sensitive, selective, simple and readily used to detect tetracycline antibiotics in food products.
Li, Daxiu; Xie, Jiaqing; Zhou, Wenjiao; Jiang, Bingying; Yuan, Ruo; Xiang, Yun
2017-11-01
The determination of the level of Cu 2+ plays important roles in disease diagnosis and environmental monitoring. By coupling Cu + -catalyzed click chemistry and metal ion-dependent DNAzyme cyclic amplification, we have developed a convenient and sensitive colorimetric sensing method for the detection of Cu 2+ in human serums. The target Cu 2+ can be reduced by ascorbate to form Cu + , which catalyzes the azide-alkyne cycloaddition between the azide- and alkyne-modified DNAs to form Mg 2+ -dependent DNAzymes. Subsequently, the Mg 2+ ions catalyze the cleavage of the hairpin DNA substrate sequences of the DNAzymes and trigger cyclic generation of a large number of free G-quadruplex sequences, which bind hemin to form the G-quadruplex/hemin artificial peroxidase to cause significant color transition of the sensing solution for sensitive colorimetric detection of Cu 2+ . This method shows a dynamic range of 5 to 500 nM and a detection limit of 2 nM for Cu 2+ detection. Besides, the level of Cu 2+ in human serums can also be determined by using this sensing approach. With the advantages of simplicity and high sensitivity, such sensing method thus holds great potential for on-site determination of Cu 2+ in different samples. Graphical abstract Sensitive colorimetric detection of copper (II) by coupling click chemistry with metal ion-dependentDNAzymes.
Dawson, Verdel K.; Meinertz, Jeffery R.; Schmidt, Larry J.; Gingerich, William H.
2003-01-01
Concentrations of chloramine-T must be monitored during experimental treatments of fish when studying the effectiveness of the drug for controlling bacterial gill disease. A surrogate analytical method for analysis of chloramine-T to replace the existing high-performance liquid chromatography (HPLC) method is described. A surrogate method was needed because the existing HPLC method is expensive, requires a specialist to use, and is not generally available at fish hatcheries. Criteria for selection of a replacement method included ease of use, analysis time, cost, safety, sensitivity, accuracy, and precision. The most promising approach was to use the determination of chlorine concentrations as an indicator of chloramine-T. Of the currently available methods for analysis of chlorine, the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method best fit the established criteria. The surrogate method was evaluated under a variety of water quality conditions. Regression analysis of all DPD colorimetric analyses with the HPLC values produced a linear model (Y=0.9602 X+0.1259) with an r2 value of 0.9960. The average accuracy (percent recovery) of the DPD method relative to the HPLC method for the combined set of water quality data was 101.5%. The surrogate method was also evaluated with chloramine-T solutions that contained various concentrations of fish feed or selected densities of rainbow trout. When samples were analyzed within 2 h, the results of the surrogate method were consistent with those of the HPLC method. When samples with high concentrations of organic material were allowed to age more than 2 h before being analyzed, the DPD method seemed to be susceptible to interference, possibly from the development of other chloramine compounds. However, even after aging samples 6 h, the accuracy of the surrogate DPD method relative to the HPLC method was within the range of 80–120%. Based on the data comparing the two methods, the U.S. Food and Drug Administration has concluded that the DPD colorimetric method is appropriate to use to measure chloramine-T in water during pivotal efficacy trials designed to support the approval of chloramine-T for use in fish culture.
NASA Astrophysics Data System (ADS)
Zhu, Qin; Li, Zhao; Mu, Lan; Zeng, Xi; Redshaw, Carl; Wei, Gang
2018-01-01
The compound (E)-8-hydroxyl-2-[(E)-2-(2, 4-dihydroxyphenyl)vinyl]-quinoline (1) has been developed as a fluorometric and colorimetric dual-modal probe for pH detection in solution and in vivo. Remarkable changes in the fluorescence intensity with large Stokes shifts and colorimetric responses were observed as a function of pH. The sensing mechanisms involving protonation and deprotonation processes over the acidic and alkaline pH ranges were confirmed by 1H NMR and IR spectroscopic analysis. Furthermore, the application of probe 1 for the imaging of live PC3 cells was successfully achieved. Test strips based on probe 1 were fabricated, and were found to act as a convenient and efficient pH test kits.
NASA Astrophysics Data System (ADS)
Wang, Yanfang; Yang, Na; Liu, Yi
2018-04-01
A novel organic small molecule with D-Pi-A structure was prepared, which was found to be a promising colorimetric and ratiometric UV-vis spetral probe for detection of phosphorylated proteins with the help of tetravalent zirconium ion. Such optical probe based on chromophore WYF-1 shows a rapid response (within 10 s) and high selectivity and sensitivity for phosphorylated proteins, giving distinct colorimetric and ratiometric UV-vis changes at 720 and 560 nm. The detection limit for phosphorylated proteins was estimated to be 100 nM. In addition, detection of phosphorylated proteins in placental tissue samples with this probe was successfully applied, which indicates that this probe holds great potential for phosphorylated proteins detection.
Colorimetric monitoring of solid-phase aldehydes using 2,4-dinitrophenylhydrazine.
Shannon, Simon K; Barany, George
2004-01-01
A simple and rapid method to achieve colorimetric monitoring of resin-bound aldehydes, based on ambient temperature reaction with 2,4-dinitrophenylhydrazine (DNPH) in the presence of dilute acid, has been developed as an adjunct to solid-phase organic synthesis and combinatorial chemistry. By this test, the presence of aldehydes is indicated by a red to dark-orange appearance, within a minute. Alternatively, resins that are free of aldehydes or in which aldehyde functions have reacted completely retain their original color. The DNPH test was demonstrated for poly(ethylene glycol)-polystyrene (PEG-PS), aminomethyl polystyrene (AMP), cross-linked ethoxylate acrylate resin (CLEAR), and acryloylated O,O'-bis(2-aminopropyl)poly(ethylene glycol) (PEGA) supports and gave results visible to the naked eye at levels as low as 18 micromol of aldehyde per gram of resin.
Suebsing, Rungkarn; Kampeera, Jantana; Sirithammajak, Sarawut; Withyachumnarnkul, Boonsirm; Turner, Warren; Kiatpathomchai, Wansika
2015-03-01
Flavobacterium columnare, the causative agent of columnaris disease in fish, affects many economically important freshwater fish species. A colorimetric method of loop-mediated isothermal amplification with the pre-addition of calcein (LAMP-calcein) was developed and used to detect the presence of F. columnare in farmed tilapia (Nile Tilapia Oreochromis niloticus and red tilapia [Nile Tilapia × Mozambique Tilapia O. mossambicus]) and rearing water. The detection method, based on a change in color from orange to green, could be performed within 45 min at 63°C. The method was highly specific, as it had no cross-detections with 14 other bacterial species, including other fish pathogens and two Flavobacterium species. The method has a minimum detection limit of 2.2 × 10(2) F. columnare CFU; thus, it is about 10 times more sensitive than conventional PCR. With this method, F. columnare was detected in gonad, gill, and blood samples from apparently healthy tilapia broodstock as well as in samples of fertilized eggs, newly hatched fry, and rearing water. The bacteria isolated from the blood were further characterized biochemically and found to be phenotypically identical to F. columnare. The amplified products from the LAMP-calcein method had 97% homology with the DNA sequence of F. columnare.
Achromatic-chromatic colorimetric sensors for on-off type detection of analytes.
Heo, Jun Hyuk; Cho, Hui Hun; Lee, Jin Woong; Lee, Jung Heon
2014-12-21
We report the development of achromatic colorimetric sensors; sensors changing their colors from achromatic black to other chromatic colors. An achromatic colorimetric sensor was prepared by mixing a general colorimetric indicator, whose color changes between chromatic colors, and a complementary colored dye with no reaction to the targeted analyte. As the color of an achromatic colorimetric sensor changes from black to a chromatic color, the color change could be much easily recognized than general colorimetric sensors with naked eyes. More importantly, the achromatic colorimetric sensors enable on-off type recognition of the presence of analytes, which have not been achieved from most colorimetric sensors. In addition, the color changes from some achromatic colorimetric sensors (achromatic Eriochrome Black T and achromatic Benedict's solution) could be recognized with naked eyes at much lower concentration ranges than normal chromatic colorimetric sensors. These results provide new opportunities in the use of colorimetric sensors for diverse applications, such as harsh industrial, environmental, and biological detection.
Mandal, Shreya; Patra, Arpita; Samanta, Animesh; Roy, Suchismita; Mandal, Arpita; Mahapatra, Tapasi Das; Pradhan, Shrabani; Das, Koushik; Nandi, Dilip Kumar
2013-01-01
Objective To investigate phytochemical screening, antimicrobial activity and qualitative thin layer chromatographic separation of flavonoid components, antioxidant activity and total flavonoid compound of Terminalia arjuna. Methods For phytochemical screening, some common and available standard tests were done. Antimicrobial bioassay was done through agar well diffusion method. Detection of antioxidant activity and flavonoid compounds were done through thin layer chromatography. Total antioxidant activity was measured by 2, 2-diphenyl-1-picrylhydrazyl (DPPH) in colorimetric method. Aluminum chloride colorimetric method was used for total flavonoid determination. Results Phytochemical screening showed the active compounds presence in high concentration, such as phytosterol, lactones, flavonoids, phenolic compounds and tannins and glycosides. The antimicrobial activity of extract showed that greater inhibition zone against Gram negative bacteria than Gram positive bacteria. This methanolic extract showed a promising antioxidant activity, as absorption of DPPH redicles decreased in DPPH free radical scavenging assay. Flavonoids components having antioxidant property present in the methanol extract at a level of 199.00 mg quercetin equivalent/g of dried methanol extract in colorimetric method. Conclusions The Terminalia arjuna bark extract revealed the presence of bio-active constituents which are known to exhibit medicinal as well as physiological activities. PMID:24093787
Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Hasanli, Nahid
2014-02-15
Rhodamine B (RhB) an available dye has been developed as novel and efficient colorimetric and fluorometric chemosensor for cyanide ions in an absolutely aqueous media. The UV-vis absorption and fluorescent emission titrations experiments have been employed to study the sensing process. RhB could act as an efficient "ON-OFF" fluorescent response for phosphotungstic acid (H3PW12O40 or PTA) based on an ion associate process. Also (RhB(+))3 · PTA(3-) could operate as an "OFF-ON" fluorescent sensor for cyanide anions based on a ligand substitution process. It has been identified as highly sensitive probe for CN(-) which responds at 0.3 and 0.04 μmol L(-1) concentration levels by absorption and fluorescent method respectively. Depending upon the sequence of addition of PTA and CN(-) ions into the solution, RhB could be as a molecular security keypad lock with PTA and CN(-) inputs. The ionic inputs to new fluorophore have been mimicked as a superimposed electronic molecular keypad lock. The results were compared successfully (>96%) with the data of a spectrophotometry approved method (EPA 9014-1) for cyanide ions. Copyright © 2013 Elsevier B.V. All rights reserved.
Sun, Kai; Chang, Yong; Zhou, Binbin; Wang, Xiaojin; Liu, Lin
2017-01-01
This article presents a general method for the detection of protein kinase with a peptide-like kinase inhibitor as the bioreceptor, and it was done by converting gold nanoparticles (AuNPs)-based colorimetric assay into sensitive electrochemical analysis. In the colorimetric assay, the kinase-specific aptameric peptide triggered the aggregation of AuNPs in solution. However, the specific binding of peptide to the target protein (kinase) inhibited its ability to trigger the assembly of AuNPs. In the electrochemical analysis, peptides immobilized on a gold electrode and presented as solution triggered together the in situ formation of AuNPs-based network architecture on the electrode surface. Nevertheless, the formation of peptide–kinase complex on the electrode surface made the peptide-triggered AuNPs assembly difficult. Electrochemical impedance spectroscopy was used to measure the change in surface property in the binding events. When a ferrocene-labeled peptide (Fc-peptide) was used in this design, the network of AuNPs/Fc-peptide produced a good voltammetric signal. The competitive assay allowed for the detection of protein kinase A with a detection limit of 20 mU/mL. This work should be valuable for designing novel optical or electronic biosensors and likely lead to many detection applications. PMID:28331314
Nitschke, Jörg; Modick, Hendrik; Busch, Ekkehard; von Rekowski, Reimund Wantoch; Altenbach, Hans-Josef; Mölleken, Helga
2011-07-15
Mushroom β-glucans are known for their activity as biological response modifiers and anticarcinogenic agents. β-1,3-1,6 Branched glucans with a triple helix tertiary structure are recognised as the most potent ones. In the present work, a colorimetric method for β-1,3-1,6-glucan quantification based on the dye Congo red is introduced. This method is specific for β-glucans with a triple helix. The β-1,3-1,6-glucan content of mycelia and fruiting bodies from various mushrooms was determined and compared with the total β-1,3-glucan content, measured by a fluorimetric method. The results show equal amounts of β-1,3-1,6- and total β-1,3-glucans in the analysed species but obvious differences between mycelia and fruiting bodies. On the average, 3% of mycelia and 8% of fruiting body dry mass consist of β-1,3-1,6-glucans. The average percentage of β-1,3-1,6-glucans in the total β-1,3-glucan content differs between mycelia (46%) and fruiting bodies (87%). Copyright © 2011 Elsevier Ltd. All rights reserved.
Xiong, Yan; Wu, Jiayi; Wang, Qing; Xu, Jing; Fang, Shenwen; Chen, Jie; Duan, Ming
2017-11-01
In this work, a miniaturized optical sensor was developed for fluoride determination in tea samples to evaluate their specific risks of fluorosis for public health based on evanescent-wave interaction. The sensor design was integrated on the optical fiber by utilizing the evanescent wave produced on the fiber surface to react with sensing reagents. According to the absorption change at 575nm, fluoride could be determined by colorimetric method and evaluated by Beer's law. With improved performances of small detection volume (1.2μL), fast analysis (0.41min), wide linear range (0.01-1.4mgL -1 ), low detection limit (3.5μgL -1 , 3σ) and excellent repeatability (2.34%), the sensor has been applied to fluoride determination in six different tea samples. Conventional spectrophotometry and ion chromatography were employed to validate the sensor's accuracy and potential application. Furthermore, this sensor fabrication provided a miniaturized colorimetric detection platform for other hazardous species monitoring based on evanescent wave interaction. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, Jia-Ming; Jiao, Li; Lin, Li-Ping; Cui, Ma-Lin; Wang, Xin-Xing; Zhang, Li-Hong; Zheng, Zhi-Yong; Jiang, Shu-Lian
2013-12-15
A label-free non-aggregation colorimetric sensor has been designed for the detection of Cu(2+), based on Cu(2+) catalyzing etching of gold nanorods (AuNRs) along longitudinal axis induced by dissolve oxygen in the presence of S2O3(2-), which caused the aspect ratio (length/width) of AuNRs to decrease and the color of the solution to distinctly change. The linear range and the detection limit (LD, calculated by 10 Sb/k, n=11) of this sensor were 0.080-4.8 µM Cu(2+) and 0.22 µM Cu(2+), respectively. This sensor has been utilized to detect Cu(2+) in tap water and human serum samples with the results agreeing well with those of inductively coupled plasma-mass spectroscopy (ICP-MS), showing its remarkable practicality. In order to prove the possibility of catalyzing AuNRs non-aggregation colorimetric sensor for the detection of Cu(2+), the morphological structures of AuNRs were characterized by high resolution transmission electron microscopy (HRTEM) and the sensing mechanism of colorimetric sensor for the detection of Cu(2+) was also discussed. © 2013 Elsevier B.V. All rights reserved.
Du, Jiayan; Zhao, Mengxin; Huang, Wei; Deng, Yuequan; He, Yi
2018-05-09
We report a molybdenum oxide (MoO 3 ) nanomaterial-based three-input logic gate that uses Sn 2+ , NO 2 - , and H + ions as inputs. Under acidic conditions, Sn 2+ is able to reduce MoO 3 nanosheets, generating oxygen-vacancy-rich MoO 3-x nanomaterials along with strong localized surface plasmon resonance (LSPR) and an intense blue solution as the output signal. When NO 2 - is introduced, the redox reaction between the MoO 3 nanosheets and Sn 2+ is strongly inhibited because the NO 2 - consumes both H + and Sn 2+ . The three-input logic gate was employed for the visual colorimetric detection of Sn 2+ and NO 2 - under different input states. The colorimetric assay's limit of detection for Sn 2+ and the lowest concentration of NO 2 - detectable by the assay were found to be 27.5 nM and 0.1 μM, respectively. The assay permits the visual detection of Sn 2+ and NO 2 - down to concentrations as low as 2 μM and 25 μM, respectively. The applicability of the logic-gate-based colorimetric assay was demonstrated by using it to detect Sn 2+ and NO 2 - in several water sources.
EDTA analysis on the Roche MODULAR analyser.
Davidson, D F
2007-05-01
Patient specimens can be subject to subtle interference from cross contamination by liquid-based, potassium-containing EDTA anticoagulant, leading to misinterpretation of results. A rapid method for EDTA analysis to detect such contamination is described. An in-house EDTA assay on the Roche MODULAR analyser was assessed for accuracy and precision by comparison with an adjusted calcium difference measurement (atomic absorption and o-cresolphthalein complexone colorimetry). EDTA method versus adjusted calcium difference showed: slope = 1.038 (95% confidence interval [CI] 0.949-1.131); intercept = 0.073 (95% CI 0.018-0.132) mmol/L; r = 0.914; n = 94. However, inter-assay precision of the calcium difference method was estimated to be poorer (coefficient of variation 24.8% versus 3.4% for the automated colorimetric method at an EDTA concentration of 0.25 mmol/L). Unequivocal contamination was observed at an EDTA concentration of > or =0.2 mmol/L. The automated method showed positive interference from haemolysis and negative interference from oxalate. The method was unaffected by lipaemia (triglycerides <20 mmol/L), icterus (bilirubin <500 micromol/L), glucose (<100 mmol/L), iron (<100 micromol/L), and citrate, phosphate or fluoride (all <2.5 mmol/L). The automated colorimetric assay described is an accurate, precise and rapid (3 min) means of detecting EDTA contamination of unhaemolysed biochemistry specimens.
A digital image method of spot tests for determination of copper in sugar cane spirits
NASA Astrophysics Data System (ADS)
Pessoa, Kenia Dias; Suarez, Willian Toito; dos Reis, Marina Ferreira; de Oliveira Krambeck Franco, Mathews; Moreira, Renata Pereira Lopes; dos Santos, Vagner Bezerra
2017-10-01
In this work the development and validation of analytical methodology for determination of copper in sugarcane spirit samples is carried out. The digital image based (DIB) method was applied along with spot test from the colorimetric reaction employing the RGB color model. For the determination of copper concentration, it was used the cuprizone - a bidentate organic reagent - which forms with copper a blue chelate in an alkaline medium. A linear calibration curve over the concentration range from 0.75 to 5.00 mg L- 1 (r2 = 0.9988) was obtained and limits of detection and quantification of 0.078 mg L- 1 and 0.26 mg L- 1 were acquired, respectively. For the accuracy studies, recovery percentages ranged from 98 to 104% were obtained. The comparison of cooper concentration results in sugar cane spirits using the DIB method and Flame Atomic Absorption Spectrometry as reference method showed no significant differences between both methods, which were performed using the paired t-test in 95% of confidence level. Thus, the spot test method associated with DIB allows the use of devices as digital cameras and smartphones to evaluate colorimetric reaction with low waste generation, practicality, quickness, accuracy, precision, high portability and low-cost.
Construction of mathematical model for measuring material concentration by colorimetric method
NASA Astrophysics Data System (ADS)
Liu, Bing; Gao, Lingceng; Yu, Kairong; Tan, Xianghua
2018-06-01
This paper use the method of multiple linear regression to discuss the data of C problem of mathematical modeling in 2017. First, we have established a regression model for the concentration of 5 substances. But only the regression model of the substance concentration of urea in milk can pass through the significance test. The regression model established by the second sets of data can pass the significance test. But this model exists serious multicollinearity. We have improved the model by principal component analysis. The improved model is used to control the system so that it is possible to measure the concentration of material by direct colorimetric method.
Wang, Yanfang; Yang, Na; Liu, Yi
2018-04-05
A novel organic small molecule with D-Pi-A structure was prepared, which was found to be a promising colorimetric and ratiometric UV-vis spetral probe for detection of phosphorylated proteins with the help of tetravalent zirconium ion. Such optical probe based on chromophore WYF-1 shows a rapid response (within 10s) and high selectivity and sensitivity for phosphorylated proteins, giving distinct colorimetric and ratiometric UV-vis changes at 720 and 560nm. The detection limit for phosphorylated proteins was estimated to be 100nM. In addition, detection of phosphorylated proteins in placental tissue samples with this probe was successfully applied, which indicates that this probe holds great potential for phosphorylated proteins detection. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhi, Lihua; Zeng, Xiaofan; Wang, Hao; Hai, Jun; Yang, Xiangliang; Wang, Baodui; Zhu, Yanhong
2017-07-18
The development of sensitive and reliable methods to monitor the presence of mercuric ions in cells and organisms is of great importance to biological research and biomedical applications. In this work, we propose a strategy to construct a solar-driven nanoprobe using a 3D Au@MoS 2 heterostructure as a photocatalyst and rhodamine B (RB) as a fluorescent and color change reporter molecule for monitoring Hg 2+ in living cells and animals. The sensing mechanism is based on the photoinduced electron formation of gold amalgam in the 3D Au@MoS 2 heterostructure under visible light illumination. This formation is able to remarkably inhibit the photocatalytic activity of the heterostructure toward RB decomposition. As a result, "OFF-ON" fluorescence and color change are produced. Such characteristics enable this new sensing platform to sensitively and selectively detect Hg 2+ in water by fluorescence and colorimetric methods. The detection limits of the fluorescence assay and colorimetric assay are 0.22 and 0.038 nM for Hg 2+ , respectively; these values are well below the acceptable limits in drinking water standards (10 nM). For the first time, such photocatalysis-based sensing platform is successfully used to monitor Hg 2+ in live cells and mice. Our work therefore opens a promising photocatalysis-based analysis methodology for highly sensitive and selective in vivo Hg 2+ bioimaging studies.
Yun, Wen; Cai, Dingzhou; Jiang, JiaoLai; Zhao, Pengxiang; Huang, Yu; Sang, Ge
2016-06-15
An enzyme-free and label-free colorimetric Pb(2+) sensor based on DNAzyme and molecular beacon (MB) has been developed and demonstrated by recycle using enzyme strand for signal amplification. The substrate strand DNA (S-DNA) of DNAzyme could be converted into MB structure with base pairs of stem part at the both ends. The MB could hybridize with enzyme strand DNA (E-DNA) to form DNAzyme, and be activated and cleaved in the presence of Pb(2+). The cleaved MB is much less stable, releasing from the DNAzyme as two product pieces. The product pieces of MB are flexible and could bind to unmodified AuNPs to effectively stabilize them against salt-induced aggregation. Then, the E-DNA is liberated to catalyze the next reaction and amplify the response signal. By taking advantage of repeated using of E-DNA, our proposed method exhibited high sensitive for Pb(2+) detection in a linear range from 0.05 to 5 nM with detection limit of 20 pM by UV-vis spectrometer. Moreover, this method was also used for determination of Pb(2+) in river water samples with satisfying results. Importantly, this strategy could reach high sensitivity without any modification and complex enzymatic or hairpins based amplification procedures. Copyright © 2016 Elsevier B.V. All rights reserved.
Cao, Gen-Xia; Wu, Xiu-Ming; Dong, Yu-Ming; Li, Zai-Jun; Wang, Guang-Li
2016-07-09
In this study, a simple and amplified colorimetric assay is developed for the detection of the enzymatic activity of glucose oxidase (GOx) based on in situ formation of a photoswitchable oxidase mimetic of PO₄(3-)-capped CdS quantum dots (QDs). GOx catalyzes the oxidation of 1-thio-β-d-glucose to give 1-thio-β-d-gluconic acid which spontaneously hydrolyzes to β-d-gluconic acid and H₂S; the generated H₂S instantly reacts with Cd(2+) in the presence of Na₃PO₄ to give PO₄(3-)-stabilized CdS QDs in situ. Under visible-light (λ ≥ 400 nm) stimulation, the PO₄(3-)-capped CdS QDs are a new style of oxidase mimic derived by producing some active species, such as h⁺, (•)OH, O₂(•-) and a little H₂O₂, which can oxidize the typical substrate (3,3,5,5-tetramethylbenzydine (TMB)) with a color change. Based on the GOx-triggered growth of the oxidase mimetics of PO₄(3-)-capped CdS QDs in situ, we developed a simple and amplified colorimetric assay to probe the enzymatic activity of GOx. The proposed method allowed the detection of the enzymatic activity of GOx over the range from 25 μg/L to 50 mg/L with a low detection limit of 6.6 μg/L. We believe the PO₄(3-)-capped CdS QDs generated in situ with photo-stimulated enzyme-mimicking activity may find wide potential applications in biosensors.
Taghdisi, Seyed Mohammad; Danesh, Noor Mohammad; Ramezani, Mohammad; Emrani, Ahmad Sarreshtehdar; Abnous, Khalil
2018-04-18
Zearalenone (ZEN) toxicity is a significant risk for human beings. Thus, it is of high importance to develop sensitive, precise, and inexpensive analytical methods for ZEN detection, especially in human serum. Here, a colorimetric aptasensor is presented for the determination of ZEN based on the nontarget-induced aptamer walker, catalytic reaction of gold nanoparticles (AuNPs), exonuclease III (Exo III) as a signal amplifier, and 4-nitrophenol as a colorimetric agent. Low amount of ZEN requirement and signal amplification are some of the distinct advantages of the proposed aptasensor. In the absence of ZEN, the aptamer (Apt) starts walking on the AuNP surface with the help of Exo III and binds to multiple complementary strands of aptamer, leading to the change of sample color from yellow to colorless. Upon the addition of ZEN, both the Apt and complementary strand exist as single-stranded DNAs on the surface of AuNPs, resulting in less access of 4-nitrophenol to the surface of AuNPs and less catalytic performance of AuNPs. In this situation, the color of the sample remains yellow (the color of 4-nitrophenol). The presented aptasensor was capable to detect ZEN in a wide linear dynamic range, 20-80 000 ng/L, with a detection limit of 10 ng/L. The prepared sensing strategy was successfully used for ZEN determination in the human serum sample.
NASA Astrophysics Data System (ADS)
Ragab, Gamal H.; Amin, Alaa S.
2004-03-01
Three accurate, rapid and simple atomic absorption spectrometric, conductometric and colorimetric methods were developed for the determination of norfloxacin (NRF), ciprofloxacin (CIP), ofloxacin (OFL) and enrofloxacin (ENF). The proposed methods depend upon the reaction of ammonium reineckate with the studied drugs to form stable precipitate of ion-pair complexes, which was dissolved in acetone. The pink coloured complexes were determined either by AAS or colorimetrically at λmax 525 nm directly using the dissolved complex. Using conductometric titration, the studied drugs could be evaluated in 50% (v/v) acetone in the range 5.0-65, 4.0-48, 5.0-56 and 6.0-72 μg ml -1 of NRF, CPF, OFL and ENF, respectively. The optimizations of various experimental conditions were described. The results obtained showed good recoveries of 99.15±1.15, 99.30±1.40, 99.60±1.50, and 99.00±1.25% with relative standard deviations of 0.81, 1.06, 0.97, and 0.69% for NRF, CPF, OFL, and ENF, respectively. Applications of the proposed methods to representative pharmaceutical formulations are successfully presented.
Colorimetric detection of biothiols based on aggregation of chitosan-stabilized silver nanoparticles
NASA Astrophysics Data System (ADS)
Mohammadi, Somayeh; Khayatian, Gholamreza
2017-10-01
We have described a simple and reliable colorimetric method for the sensing of biothiols such as cysteine, homocysteine, and glutathione in biological samples. The selective binding of chitosan capped silver nanoparticles to biothiols induced aggregation of the chitosan-Ag NPs. But the other amino acids that do not have thiol group cannot aggregate the chitosan-Ag NPs. Aggregation of chitosan-Ag NPs has been confirmed with UV-vis absorption spectra, zeta potential and transmission electron microscopy images. Under optimum conditions, good linear relationships existed between the absorption ratios (at A500/A415) and the concentrations of cysteine, homocysteine, and glutathione in the range of 0.1-10.0 μM with detection limits of 15.0, 84.6 and 40.0 nM, respectively. This probe was successfully applied to detect these biothiols in biological samples (urine and plasma).
Kynetic resazurin assay (KRA) for bacterial quantification of foodborne pathogens
NASA Astrophysics Data System (ADS)
Arenas, Yaxal; Mandel, Arkady; Lilge, Lothar
2012-03-01
Fast detection of bacterial concentrations is important for the food industry and for healthcare. Early detection of infections and appropriate treatment is essential since, the delay of treatments for bacterial infections tends to be associated with higher mortality rates. In the food industry and in healthcare, standard procedures require the count of colony-forming units in order to quantify bacterial concentrations, however, this method is time consuming and reports require three days to be completed. An alternative is metabolic-colorimetric assays which provide time efficient in vitro bacterial concentrations. A colorimetric assay based on Resazurin was developed as a time kinetic assay (KRA) suitable for bacterial concentration measurements. An optimization was performed by finding excitation and emission wavelengths for fluorescent acquisition. A comparison of two non-related bacteria, foodborne pathogens Escherichia coli and Listeria monocytogenes, was performed in 96 well plates. A metabolic and clonogenic dependence was established for fluorescent kinetic signals.
Colorimetric detection of glucose based on gold nanoparticles coupled with silver nanoparticles
NASA Astrophysics Data System (ADS)
Gao, Yan; Wu, Yiting; Di, Junwei
2017-02-01
We have coupled gold nanoparticles (AuNPs) with silver nanoparticles (AgNPs) to assemble a plasmonic sensing platform for colorimetric detection of glucose. In this system, small AuNPs ( 4 nm) can act as glucose oxidase (GOD) mimic enzyme to catalytically oxidize glucose in the presence of oxygen, producing hydrogen peroxide, which dissolves AgNPs to lead the color changes. Glucose can be detected not only by naked eyes (from yellow to red) but also by spectrophotometer in the concentration range of 5-70 μM, with detection limit of 3 μM. More importantly, we found that L-cysteine added in the system can markedly improve the selectivity for the detection of glucose. The proposed method was used to application for the detection of glucose in human serum with satisfactory results. This system is simple and low cost without using any enzymes and organic chromogenic agents.
Wu, Juanjuan; Ye, Zhuo; Wu, Feng; Wang, Hongying; Zeng, Lintao; Bao, Guang-Ming
2018-05-01
Thiophenols are a class of highly toxic environmental pollutant, hence it is very necessary to monitor thiophenols in environment and living cells with an efficient and reliable method. Herein, a novel fluorescent probe for thiophenols has been developed, which exhibited a colorimetric and fluorescence turn-on dual response towards thiophenols with good selectivity and fast response. The sensing mechanism for thiophenols was attributed to nucleophilic substitution reaction, which was confirmed by HPLC. The probe exhibited good recovery (from 90% to 107%) and low limit of detection for thiophenols (37nM) in industrial wastewater. Moreover, the probe has been successfully employed to visualize thiophenol in living cells. Therefore, the fluorescent probe has good capability for monitoring thiophenols in environmental samples and biological systems. Copyright © 2018 Elsevier B.V. All rights reserved.
Hill, April A; Lipert, Robert J; Porter, Marc D
2010-03-15
The increase in bacterial resistance to antibiotics has led to resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). However, growing concerns about the possible toxicity of colloidal silver to bacteria, aquatic organisms and humans have led to recently issued regulations by the US EPA and FDA regarding the usage of silver. As part of an ongoing project, we have developed a rapid, simple method for determining total silver, both ionic (silver(I)) and colloidal, in 0.1-1mg/L aqueous samples, which spans the ISS potable water target of 0.3-0.5mg/L (total silver) and meets the US EPA limit of 0.1mg/L in drinking water. The method is based on colorimetric solid-phase extraction (C-SPE) and involves the extraction of silver(I) from water samples by passage through a solid-phase membrane impregnated with the colorimetric reagent DMABR (5-[4-(dimethylamino)benzylidene]rhodanine). Silver(I) exhaustively reacts with impregnated DMABR to form a colored compound, which is quantified using a handheld diffuse reflectance spectrophotometer. Total silver is determined by first passing the sample through a cartridge containing Oxone, which exhaustively oxidizes colloidal silver to dissolved silver(I). The method, which takes less than 2 min to complete and requires only approximately 1 mL of sample, has been validated through a series of tests, including a comparison with the ICP-MS analysis of a water sample from ISS that contained both silver(I) and colloidal silver. Potential earth-bound applications are also briefly discussed. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Evaluation of parameters of color profile models of LCD and LED screens
NASA Astrophysics Data System (ADS)
Zharinov, I. O.; Zharinov, O. O.
2017-12-01
The purpose of the research relates to the problem of parametric identification of the color profile model of LCD (liquid crystal display) and LED (light emitting diode) screens. The color profile model of a screen is based on the Grassmann’s Law of additive color mixture. Mathematically the problem is to evaluate unknown parameters (numerical coefficients) of the matrix transformation between different color spaces. Several methods of evaluation of these screen profile coefficients were developed. These methods are based either on processing of some colorimetric measurements or on processing of technical documentation data.
Hayden, S R; Sciammarella, J; Viccellio, P; Thode, H; Delagi, R
1995-06-01
To evaluate the ability of a disposable, colorimetric end-tidal CO2 detector to verify proper endotracheal (ET) tube placement in out-of-hospital cardiac arrest, and to correlate semiquantitative CO2 measurements with the rate of return of spontaneous circulation (ROSC). Prospective, observational study using a convenience sample of intubated out-of-hospital cardiac arrest patients. A disposable, colorimetric end-tidal CO2 detector was attached to the ET tube after intubation. In the absence of a colorimetric change, the paramedics reassessed the tube placement and could reintubate the patient. Tube placement was verified at the hospital. Paramedics were instructed to contact the base station and report the colorimetric change upon hospital arrival. ROSC was defined as restoration of a self-sustaining pulse until hospital arrival. Between December 1990 and May 1993, ET tubes were placed in 566 victims of out-of-hospital cardiac arrest. 541 of the 566 intubations (95.6%) were associated with a color change. In one case with a color change and out-of-hospital clinical evidence of proper tube placement, the tube was determined to be in the esophagus at the hospital. Correct placement of the remaining 565 of 566 (99.8%) tubes was verified. Of the 566 patients who had a colorimetric change, 91 (16%) had ROSC vs one of 25 (4%) patients who did not have a color change. In one subgroup (n = 179), the degree of color change was highly associated with ROSC (p = 0.004). A disposable, colorimetric end-tidal CO2 detector appears reliable in verifying proper ET tube placement in victims of out-of-hospital cardiac arrest. The degree of color change correlates with the probability of ROSC.
Reverse phase protein microarrays: fluorometric and colorimetric detection.
Gallagher, Rosa I; Silvestri, Alessandra; Petricoin, Emanuel F; Liotta, Lance A; Espina, Virginia
2011-01-01
The Reverse Phase Protein Microarray (RPMA) is an array platform used to quantitate proteins and their posttranslationally modified forms. RPMAs are applicable for profiling key cellular signaling pathways and protein networks, allowing direct comparison of the activation state of proteins from multiple samples within the same array. The RPMA format consists of proteins immobilized directly on a nitrocellulose substratum. The analyte is subsequently probed with a primary antibody and a series of reagents for signal amplification and detection. Due to the diversity, low concentration, and large dynamic range of protein analytes, RPMAs require stringent signal amplification methods, high quality image acquisition, and software capable of precisely analyzing spot intensities on an array. Microarray detection strategies can be either fluorescent or colorimetric. The choice of a detection system depends on (a) the expected analyte concentration, (b) type of microarray imaging system, and (c) type of sample. The focus of this chapter is to describe RPMA detection and imaging using fluorescent and colorimetric (diaminobenzidine (DAB)) methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, Haihang; Yang, Kuikun; Tao, Jing
Enzyme-based colorimetric assays have been widely used in research labs and clinical diagnosis for decades. Nevertheless, as constrained by the performance of enzymes, their detection sensitivity has not been substantially improved in recent years, which inhibits many critical applications such as early detection of cancers. In this work, we demonstrate an enzyme-free signal amplification technique, based on gold vesicles encapsulated with Pd-Ir nanoparticles as peroxidase mimics, for colorimetric assay of disease biomarkers with significantly enhanced sensitivity. This technique overcomes the intrinsic limitations of enzymes, thanks to the superior catalytic efficiency of peroxidase mimics and the efficient loading and release ofmore » these mimics. Using human prostate surface antigen as a model biomarker, we demonstrated that the enzyme-free assay could reach a limit of detection at the femtogram/mL level, which is over 10 3-fold lower than that of conventional enzyme-based assay when the same antibodies and similar procedure were used.« less
Ye, Haihang; Yang, Kuikun; Tao, Jing; ...
2017-01-30
Enzyme-based colorimetric assays have been widely used in research labs and clinical diagnosis for decades. Nevertheless, as constrained by the performance of enzymes, their detection sensitivity has not been substantially improved in recent years, which inhibits many critical applications such as early detection of cancers. In this work, we demonstrate an enzyme-free signal amplification technique, based on gold vesicles encapsulated with Pd-Ir nanoparticles as peroxidase mimics, for colorimetric assay of disease biomarkers with significantly enhanced sensitivity. This technique overcomes the intrinsic limitations of enzymes, thanks to the superior catalytic efficiency of peroxidase mimics and the efficient loading and release ofmore » these mimics. Using human prostate surface antigen as a model biomarker, we demonstrated that the enzyme-free assay could reach a limit of detection at the femtogram/mL level, which is over 10 3-fold lower than that of conventional enzyme-based assay when the same antibodies and similar procedure were used.« less
A novel colorimetric assay for rapid detection of cysteine and Hg²⁺ based on gold clusters.
Wang, Yi-Wei; Tang, Shurong; Yang, Huang-Hao; Song, Hongbo
2016-01-01
Inhibition and recovery of the catalytic activity of bovine serum albumin-capped gold nanoclusters (BSA-AuNCs) is observed for the first time by introduction of cysteine and Hg(2+). The prepared BSA-AuNCs possess highly intrinsic peroxidase-like activity. It can catalyze the oxidation of 3, 3, 5, 5-tetramethylbenzidine by H2O2 to produce a blue colored product. Based on this phenomenon, a new colorimetric assay for rapid, selective and sensitive detection of cysteine and Hg(2+) in aqueous solution has been demonstrated. The interaction process between target molecule and BSA-AuNCs is very fast, so that the whole test can be completed within ten minutes. Moreover, the fabricated colorimetric sensor is simple and cost-effective, without the need of nucleic acid based recognition element and complicated washing, separation and labeling process, thus holds great promise for routine analysis of cysteine and Hg(2+) in real samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Holman, Benjamin W B; Mao, Yanwei; Coombs, Cassius E O; van de Ven, Remy J; Hopkins, David L
2016-11-01
The relationship between instrumental colorimetric values (L*, a*, b*, the ratio of reflectance at 630nm and 580nm) and consumer perception of acceptable beef colour was evaluated using a web-based survey and standardised photographs of beef m. longissimus lumborum with known colorimetrics. Only L* and b* were found to relate to average consumer opinions of beef colour acceptability. Respondent nationality was also identified as a source of variation in beef colour acceptability score. Although this is a preliminary study with the findings necessitating additional investigation, these results suggest L* and b* as candidates for developing instrumental thresholds for consumer beef colour expectations. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Hasanli, Nahid
2015-03-01
In this paper we manifest a novel rhodamine B (RhB) based colorimetric chemosensor for molybdenum and citrate ions (Cit3-) in an absolutely aqueous media. It has been identified as highly sensitive probe for Mo6+ which responds at 4.0 nmol L-1 concentration levels. RhB while combined with Mo6+ in aqueous solution displays a color changing from pink to purple which could be quickly dissociated by the addition of citrate in this system so that reversible color changes from purple to pink can be achieved. The comparison of this method with some other methods for citrate indicates that this is the only method which can detect citrate in aqueous solution by color changes. This chemosensor can be applied for quantification of citrate with a linear range covering from 1.67 × 10-7 to 1.22 × 10-5 M and a detection limit of 2.0 × 10-8 M. Moreover, the response of the chemosensor toward Mo6+ and citrate is fast. In addition, based on above sensing mechanism, an IMPLICATION logic operation can be achieved using Mo6+ ion and Cit3- as the inputs, making RhB a promising candidate for further applications in molecular logic devices and also indicates that RhB is suitable for the detection of Mo6+ and Cit3- ions in real samples.
Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Hasanli, Nahid
2015-03-15
In this paper we manifest a novel rhodamine B (RhB) based colorimetric chemosensor for molybdenum and citrate ions (Cit(3-)) in an absolutely aqueous media. It has been identified as highly sensitive probe for Mo(6+) which responds at 4.0 nmol L(-1) concentration levels. RhB while combined with Mo(6+) in aqueous solution displays a color changing from pink to purple which could be quickly dissociated by the addition of citrate in this system so that reversible color changes from purple to pink can be achieved. The comparison of this method with some other methods for citrate indicates that this is the only method which can detect citrate in aqueous solution by color changes. This chemosensor can be applied for quantification of citrate with a linear range covering from 1.67×10(-7) to 1.22×10(-5) M and a detection limit of 2.0×10(-8) M. Moreover, the response of the chemosensor toward Mo(6+) and citrate is fast. In addition, based on above sensing mechanism, an IMPLICATION logic operation can be achieved using Mo(6+) ion and Cit(3-) as the inputs, making RhB a promising candidate for further applications in molecular logic devices and also indicates that RhB is suitable for the detection of Mo(6+) and Cit(3-) ions in real samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Delhaes, L; Lazaro, J E; Gay, F; Thellier, M; Danis, M
1999-01-01
Malarial lactate dehydrogenase (LDH), which uses 3-acetyl pyridine adenine dinucleotide as coenzyme in a reaction leading to the formation of pyruvate from L-lactate, may be used to study the susceptibility of Plasmodium falciparum to a drug in vitro. Several methods to determine the activity of this enzyme are available. One, the colorimetric method of Makler and colleagues, was modified slightly, by using sodium-2,3-bis-[2-methoxy-4-nitro-5-sulphophenyl]-2H-tetrazolium-5 - carboxanilide (XTT) and following the reaction by measuring the optical density at 450 nm. Using two, culture-adapted strains of P. falciparum, this LDH assay was compared with the unmodified Makler's assay and with the isotopic microtest based on the incorporation of tritium-labelled hypoxanthine. Fresh, clinical P. falciparum isolates were also tested in the presence of several drugs, including chloroquine, mefloquine, quinine, halofantrine, atovaquone and qinghaosu derivatives. The results of the three assays were correlated for all the drugs tested except atovaquone. The two enzymatic assays are non-radioactive, rapid, reliable, inexpensive to perform and semi-automatic. However, they do require an initial parasitaemia of 2% with a haematocrit of 1.8%.
NASA Astrophysics Data System (ADS)
Larki, A.
2017-02-01
In this work, the intrinsic colorimetric property of carbon dots (CDs) was utilized for the determination of fenitrothion by applying dispersive liquid-liquid microextraction (DLLME) method. Label free CDs are extracted into carbon tetrachloride via assistance of trioctylmethylammonium chloride (Aliquat 336), which also acts as a disperser agent in this technique. The enriched CDs show an absorption signal at 365 nm, which increases in the presence of fenitrothion. The absorbance increase of CDs in organic phase was used as an analytical signal for the determination of fenitrothion. The synthesized CDs were characterized by UV-visible, fluorescence, Fourier transform infrared (FT-IR) and transmission electron microscopic (TEM). Under the optimized conditions, beer's law was obeyed in the range of 1.0-250.0 ng mL- 1 of fenitrothion with the limit of detection for fenitrothion was 0.2 ng mL- 1. The relative standard deviation for eight replicate measurements of fenitrothion at concentrations of 25 and 100 ng mL- 1 were calculated to be 1.5 and 3.7%, respectively. The proposed method was successfully applied in the determination of fenitrothion in water samples with satisfactory results.
NASA Astrophysics Data System (ADS)
Wang, Huiying; Chen, Dinglong; Yu, Longquan; Chang, Ming; Ci, Lijie
2015-02-01
We have developed a rapid, sensitive, one-step, and selective colorimetric detection method for melamine (MEL) in milk powder based upon an in-situ formation of silver nanoparticles (AgNPs) through modified Tollens process at room temperature. The triazine ring N atoms of MEL molecule were strategically designed to complex the Ag+ through electron donor-acceptor interaction. During the AgNPs formation procedure, the MEL molecule, which has been covalently bonded with the Ag+ ions, was adsorbed to the surface of as-prepared AgNPs, resulting in the aggregation of the adjacent AgNPs with detectable decreases of absorption signal. The concentration of MEL can be determined with the naked eye or a UV-vis spectrometer at which the yellow-to-brown color change associated with aggregate enhancement takes place. This method enables rapid (less than 30 min) and sensitive (limit of detection, LOD, 10 nM) detection, and it was also able to discriminate MEL from sixteen other milk relevant coexisting compounds. This assay does not utilize organic cosolvents, enzymatic reactions, light-sensitive dye molecules, lengthy protocols, or sophisticated instrumentation thereby overcoming some of the limitations of conventional methods.
Cheng, Jinghui; Gou, Fei; Zhang, Xiaohong; Shen, Guangyu; Zhou, Xiangge; Xiang, Haifeng
2016-09-19
We report a class of multiresponsive colorimetric and fluorescent pH probes based on three different reaction mechanisms including cation exchange, protonation, and hydrolysis reaction of K(I), Ca(II), Zn(II), Cu(II), Al(III), and Pd(II) Salen complexes. Compared with traditional pure organic pH probes, these complex-based pH probes exhibited a much better selectivity due to the shielding function of the filled-in metal ion in the complex. Their pH sensing performances were affected by the ligand structure and the central metal ion. This work is the first report of "off-on-on'-off" colorimetric and fluorescent pH probes that possess three different reaction mechanisms and should inspire the design of multiple-responsive probes for important analytes in biological systems.
Lee, Seul Ah; You, Ga Rim; Choi, Ye Won; Jo, Hyun Yong; Kim, Ah Ram; Noh, Insup; Kim, Sung-Jin; Kim, Youngmee; Kim, Cheal
2014-05-14
A multifunctional fluorescent and colorimetric receptor 1 ((E)-N'-((8-hydroxy-1,2,3,5,6,7-hexahydropyrido[3,2,1-ij]quinolin-9-yl)methylene)benzohydrazide) for the detection of both Al(3+) and CN(-) in aqueous solution has been developed. Receptor 1 exhibited an excellent selective fluorescence response toward Al(3+). The sensitivity of the fluorescent based assay (0.193 μM) for Al(3+) is far below the limit in the World Health Organization (WHO) guidelines for drinking water (7.41 μM). In addition, receptor 1 showed an excellent detection ability in a wide pH range of 4-10 and also in living cells. Moreover, receptor 1 showed a highly selective colorimetric response to CN(-) by changing its color from colorless to yellow immediately without any interference from other anions.
NASA Astrophysics Data System (ADS)
Zhang, Shanshan; Sun, Tao; Xiao, Dejun; Yuan, Fang; Li, Tianduo; Wang, Enhua; Liu, Haixia; Niu, Qingfen
2018-01-01
A novel dual-responsive colorimetric and fluorescent chemosensor L based on diketopyrrolopyrrole derivative for Fe3 + detection was designed and synthesized. In presence of Fe3 +, sensor L displayed strong colorimetric response as amaranth to rose pink and significant fluorescence enhancement and chromogenic change, which served as a naked-eye indicator by an obvious color change from purple to red. The binding constant for L-Fe3 + complex was found as 2.4 × 104 with the lower detection limit of 14.3 nM. The sensing mechanism was investigated in detail by fluorescence measurements, IR and 1H NMR spectra. Sensor L for Fe3 + detection also exhibited high anti-interference performance, good reversibility, wide pH response range and instantaneous response time. Furthermore, the sensor L has been used to quantify Fe3 + ions in practical water samples with good recovery.
Leenheer, J.A.; Wershaw, R. L.; Brown, P.A.; Noyes, T.I.
1991-01-01
??? Poly(ethylene glycol) (PEG) residues were detected in organic solute isolates from surface water by 1H nuclear magnetic resonance spectrometry (NMR), 13C NMR spectrometry, and colorimetric assay. PEG residues were separated from natural organic solutes in Clear Creek, CO, by a combination of methylation and chromatographic procedures. The isolated PEG residues, characterized by NMR spectrometry, were found to consist of neutral and acidic residues that also contained poly(propylene glycol) moieties. The 1H NMR and the colorimetric assays for poly(ethylene glycol) residues were done on samples collected in the lower Mississippi River and tributaries between St. Louis, MO, and New Orleans, LA, in July-August and November-December 1987. Aqueous concentrations for poly(ethylene glycol) residues based on colorimetric assay ranged from undetectable to ???28 ??g/L. Concentrations based on 1H NMR spectrometry ranged from undetectable to 145 ??g/L.
NASA Astrophysics Data System (ADS)
Ivrigh, Zahra Jafar-Nezhad; Fahimi-Kashani, Nafiseh; Hormozi-Nezhad, M. Reza
2017-12-01
There is a growing interest in developing high-performance sensors monitoring fungicides, due to their broadly usage and their adverse effects on humans and wildlife. In the present study, a colorimetric probe has been proposed for detection of prothioconazole based on aggregation of unmodified silver nanoparticles (AgNPs). Under optimized condition, linear relationships between the concentration of prothioconazole and the absorbance ratio of A500/A395 were found over the range of 0.01 μg·mL- 1 to 0.4 μg·mL- 1 with quantification limit as low as 1.7 ng·mL- 1. Furthermore, AgNPs color change from yellow to pink-orange in presence of prothioconazole, indicates highly sensitive naked-eye colorimetric assay for quantifying prothioconazole in real applications. The proposed approach was successfully used for the determination of prothioconazole in wheat flour and paddy water sample.
Antweiler, Ronald C.; Patton, Charles J.; Taylor, Howard E.
1996-01-01
The apparatus and methods used for the automatic, colorimetric determinations of dissolved nutrients (nitrate plus nitrite, nitrite, ammonium and orthophosphate) in natural waters are described. These techniques allow for the determination of nitrate plus nitrite for the concentration range 0.02 to 8 mg/L (milligrams per liter) as N (nitrogen); for nitrite, the range is 0.002 to 1.0 mg/L as N; for ammonium, the range is 0.006 to 2.0 mg/L as N; and for orthophosphate, the range is 0.002 to 1.0 mg/L as P (phosphorus). Data are presented that demonstrate the accuracy, precision and quality control of the methods.
An Improved Method for Determination of Cyanide Content in Bitter Almond Oil.
Chen, Jia; Liu, Lei; Li, Mengjun; Yu, Xiuzhu; Zhang, Rui
2018-01-01
An improved colorimetric method for determination of cyanide content in bitter almond oil was developed. The optimal determination parameters were as follows: volume ratio of hydrochloric acid to bitter almond oil (v/v), 1.5:1; holding time for hydrolysis, 120 min; and volume ratio of distillation solution to bitter almond oil (v/v), 8:1. Analytical results showed that the relative standard deviations (SDs) of determinations were less than 10%, which satisfies the test requirements. The results of high-performance liquid chromatography and measurements exhibited a significant correlation (R = 0.9888, SD = 0.2015). Therefore, the improved colorimetric method can be used to determine cyanide content in bitter almond oil.
NASA Astrophysics Data System (ADS)
Pylaev, T. E.; Khanadeev, V. A.; Khlebtsov, B. N.; Dykman, L. A.; Bogatyrev, V. A.; Khlebtsov, N. G.
2011-07-01
We introduce a new genosensing approach employing CTAB (cetyltrimethylammonium bromide)-coated positively charged colloidal gold nanoparticles (GNPs) to detect target DNA sequences by using absorption spectroscopy and dynamic light scattering. The approach is compared with a previously reported method employing unmodified CTAB-coated gold nanorods (GNRs). Both approaches are based on the observation that whereas the addition of probe and target ssDNA to CTAB-coated particles results in particle aggregation, no aggregation is observed after addition of probe and nontarget DNA sequences. Our goal was to compare the feasibility and sensitivity of both methods. A 21-mer ssDNA from the human immunodeficiency virus type 1 HIV-1 U5 long terminal repeat (LTR) sequence and a 23-mer ssDNA from the Bacillus anthracis cryptic protein and protective antigen precursor (pagA) genes were used as ssDNA models. In the case of GNRs, unexpectedly, the colorimetric test failed with perfect cigar-like particles but could be performed with dumbbell and dog-bone rods. By contrast, our approach with cationic CTAB-coated GNPs is easy to implement and possesses excellent feasibility with retention of comparable sensitivity—a 0.1 nM concentration of target cDNA can be detected with the naked eye and 10 pM by dynamic light scattering (DLS) measurements. The specificity of our method is illustrated by successful DLS detection of one-three base mismatches in cDNA sequences for both DNA models. These results suggest that the cationic GNPs and DLS can be used for genosensing under optimal DNA hybridization conditions without any chemical modifications of the particle surface with ssDNA molecules and signal amplification. Finally, we discuss a more than two-three-order difference in the reported estimations of the detection sensitivity of colorimetric methods (0.1 to 10-100 pM) to show that the existing aggregation models are inconsistent with the detection limits of about 0.1-1 pM DNA and that other explanations should be developed.
Guo, Zhiyong; Jia, Yaru; Song, Xinxin; Lu, Jing; Lu, Xuefei; Liu, Baoqing; Han, Jiaojiao; Huang, Youju; Zhang, Jiawei; Chen, Tao
2018-05-15
Conventional methods for the detection of Vibrio parahemolyticus (VP) usually need tedious, labor-intensive processes, and have low sensitivity, which further limits their practical applications. Herein, we developed a simple and efficient colorimetry and surface-enhanced Raman scattering (SERS) dual-mode immunosensor for sensitive detection of VP, by employing giant Au vesicles with anchored tiny gold nanowires (AuNW) as a smart probe. Due to the larger specific surface and special hollow structure of giant Au vesicles, silver staining would easily lead to vivid color change for colorimetric analysis and further amplify SERS signals. The t-test was further used to determine if two sets of data from colorimetry and SERS were significantly different from each other. The result shows that there was no significant difference between data from the two methods. Two sets of data can mutually validate each other and avoid false positive and negative detection. The designed colorimetry-SERS dual-mode sensor would be very promising in various applications such as food safety inspection, personal healthcare, and on-site environmental monitoring.
NASA Technical Reports Server (NTRS)
Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.;
2007-01-01
Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.
An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.
Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu
2015-10-07
This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.
Ding, Nan; Cao, Qian; Zhao, Hong; Yang, Yimin; Zeng, Lixi; He, Yujian; Xiang, Kaixiang; Wang, Guangwei
2010-01-01
In this report, we present a new method for visual detection of Pb2+. Gold nanoparticles (Au-NPs) were synthesized in one step at room temperature, using gallic acid (GA) as reducer and stabilizer. Pb2+ is added during the gold nanoparticle formation. Analysis of Pb2+ is conducted by a dual strategy, namely, colorimetry and spectrometry. During Au-NPs synthesis, addition of Pb2+ would lead to formation of Pb-GA complex, which can induce the aggregation of newly-formed small unstable gold nanoclusters. Consequently, colorimetric detection of trace Pb2+ can be realized. As the Pb2+ concentration increases, the color turns from red-wine to purple, and finally blue. This method offers a sensitive linear correlation between the shift of the absorption band (Δλ) and logarithm of Pb2+ concentration ranging from 5.0 × 10−8 to 1.0 × 10−6 M with a linear fit coefficient of 0.998, and a high selectivity for Pb2+ detection with a low detection limit down to 2.5 × 10−8 M. PMID:22163517
Shi, Xinhao; Gu, Wei; Zhang, Cuiling; Zhao, Longyun; Peng, Weidong; Xian, Yuezhong
2015-03-14
In this work, we developed a novel, label-free, colorimetric sensor for Pb(2+) detection based on the acceleration of gold leaching by graphene oxide (GO) at room temperature. Gold nanoparticles (AuNPs) can be dissolved in a thiosulfate (S2O3(2-)) aqueous environment in the presence of oxygen; however, the leaching rate is very slow due to the high activation energy (27.99 kJ mol(-1)). In order to enhance the reaction rate, some accelerators should be added. In comparison with the traditional accelerators (metal ions or middle ligands), we found that GO could efficiently accelerate the gold leaching reaction. Kinetic data demonstrate that the dissolution rate of gold in the Pb(2+)-S2O3(2-)-GO system is 5 times faster than that without GO at room temperature. In addition, the effects of surface modification and the nanoparticle size on the etching of AuNPs were investigated. Based on the GO-accelerated concentration-dependent colour changes of AuNPs, a colorimetric sensor for Pb(2+) detection was developed with a linear range from 0.1 to 20 μM and the limit of detection (LOD) was evaluated to be 0.05 μM. This colorimetric assay is simple, low-cost, label-free, and has numerous potential applications in the field of environmental chemistry.
Lin, Zhenyu; Yang, Weiqiang; Zhang, Guiyun; Liu, Qida; Qiu, Bin; Cai, Zongwei; Chen, Guonan
2011-08-28
A novel catalytic colorimetric assay assisted by nicking endonuclease signal amplification (NESA) was developed. With the signal amplification, the detection limit of the p53 target gene can be as low as 1 pM, which is nearly 5 orders of magnitude lower than that of other previously reported colorimetric DNA detection strategies based on catalytic DNAzyme.
Moonrungsee, Nuntaporn; Pencharee, Somkid; Jakmunee, Jaroon
2015-05-01
A field deployable colorimetric analyzer based on an "Android mobile phone" was developed for the determination of available phosphorus content in soil. An inexpensive mobile phone embedded with digital camera was used for taking photograph of the chemical solution under test. The method involved a reaction of the phosphorus (orthophosphate form), ammonium molybdate and potassium antimonyl tartrate to form phosphomolybdic acid which was reduced by ascorbic acid to produce the intense colored molybdenum blue. The software program was developed to use with the phone for recording and analyzing RGB color of the picture. A light tight box with LED light to control illumination was fabricated to improve precision and accuracy of the measurement. Under the optimum conditions, the calibration graph was created by measuring blue color intensity of a series of standard phosphorus solution (0.0-1.0mgPL(-1)), then, the calibration equation obtained was retained by the program for the analysis of sample solution. The results obtained from the proposed method agreed well with the spectrophotometric method, with a detection limit of 0.01mgPL(-1) and a sample throughput about 40h(-1) was achieved. The developed system provided good accuracy (RE<5%) and precision (RSD<2%, intra- and inter-day), fast and cheap analysis, and especially convenient to use in crop field for soil analysis of phosphorus nutrient. Copyright © 2015 Elsevier B.V. All rights reserved.
Nikzad, Nasrin; Karami, Zahra
2018-04-14
Changes in choline levels can be associated with diseases such as Alzheimer, Parkinson, Huntington, fatty liver, interstitial lung abnormalities, autism and so on. Therefore, quantitative determination of choline is important in the biological and clinical analysis. So far, several methods have been investigated for measuring choline in the body fluids, each of which has disadvantages such as the need for specialist ability, complexity, and high cost. For this purpose, a facile and sensitive colorimetric biosensor based on DNAzyme-choline oxidase coupling used for the determination of choline. In this method, the first, choline oxidase produces H 2 O 2 and betaine in the presence of choline and oxygen, then, the DNAzyme converts colorless ABTS into green ABTS + radicals. Compared to the previous methods, the linear range and the limit of detection of this talented biosensor were 0.1-25 μM and 22 nM. Choline measurement using this biosensor has shown satisfactory selectivity and repeatability. Its recovery was 96.9-103.7%, which shows the reliability of biosensor assay in biological samples. Simplicity, low cost, naked eye, high sensitivity, and precision are the benefits of this biosensor. Taken to gather, the proposed system can be considered as a great biosensor for measuring choline levels especially in point of care diagnostic. Copyright © 2018 Elsevier B.V. All rights reserved.
Patton, Charles J.; Kryskalla, Jennifer R.
2013-01-01
A multiyear research effort at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) evaluated several commercially available nitrate reductase (NaR) enzymes as replacements for toxic cadmium in longstanding automated colorimetric air-segmented continuous-flow analyzer (CFA) methods for determining nitrate plus nitrite (NOx) in water. This research culminated in USGS approved standard- and low-level enzymatic reduction, colorimetric automated discrete analyzer NOx methods that have been in routine operation at the NWQL since October 2011. The enzyme used in these methods (AtNaR2) is a product of recombinant expression of NaR from Arabidopsis thaliana (L.) Heynh. (mouseear cress) in the yeast Pichia pastoris. Because the scope of the validation report for these new automated discrete analyzer methods, published as U.S. Geological Survey Techniques and Methods 5–B8, was limited to performance benchmarks and operational details, extensive foundational research with different enzymes—primarily YNaR1, a product of recombinant expression of NaR from Pichia angusta in the yeast Pichia pastoris—remained unpublished until now. This report documents research and development at the NWQL that was foundational to development and validation of the discrete analyzer methods. It includes: (1) details of instrumentation used to acquire kinetics data for several NaR enzymes in the presence and absence of known or suspected inhibitors in relation to reaction temperature and reaction pH; and (2) validation results—method detection limits, precision and bias estimates, spike recoveries, and interference studies—for standard- and low-level automated colorimetric CFA-YNaR1 reduction NOx methods in relation to corresponding USGS approved CFA cadmium-reduction (CdR) NOx methods. The cornerstone of this validation is paired sample statistical and graphical analysis of NOx concentrations from more than 3,800 geographically and seasonally diverse surface-water and groundwater samples that were analyzed in parallel by CFA-CdR and CFA enzyme-reduction methods. Finally, (3) demonstration of a semiautomated batch procedure in which 2-milliliter analyzer cups or disposable spectrophotometer cuvettes serve as reaction vessels for enzymatic reduction of nitrate to nitrite prior to analytical determinations. After the reduction step, analyzer cups are loaded onto CFA, flow injection, or discrete analyzers for simple, rapid, automatic nitrite determinations. In the case of manual determinations, analysts dispense colorimetric reagents into cuvettes containing post-reduction samples, allow time for color to develop, insert cuvettes individually into a spectrophotometer, and record percent transmittance or absorbance in relation to a reagent blank. Data presented here demonstrate equivalent analytical performance of enzymatic reduction NOx methods in these various formats to that of benchmark CFA-CdR NOx methods.
Fan, Daoqing; Zhai, Qingfeng; Zhou, Weijun; Zhu, Xiaoqing; Wang, Erkang; Dong, Shaojun
2016-11-15
Herein, a gold nanoparticles (AuNPs) based label-free colorimetric aptasensor for simple, sensitive and selective detection of Pt (II) was constructed for the first time. Four bases (G-G mismatch) mismatched streptavidin aptamer (MSAA) was used to protect AuNPs from salt-induced aggregation and recognize Pt (II) specifically. Only in the presence of Pt (II), coordination occurs between G-G bases and Pt (II), leading to the activation of streptavidin aptamer. Streptavidin coated magnetic beads (MBs) were used as separation agent to separate Pt (II)-coordinated MSAA. The residual less amount of MSAA could not efficiently protect AuNPs anymore and aggregation of AuNPs will produce a colorimetric product. With the addition of Pt (II), a pale purple-to-blue color variation could be observed by the naked eye. A detection limit of 150nM and a linear range from 0.6μM to 12.5μM for Pt (II) could be achieved without any amplification. Copyright © 2016 Elsevier B.V. All rights reserved.
Acid-Base Properties of Azo Dyes in Solution Studied Using Spectrophotometry and Colorimetry
NASA Astrophysics Data System (ADS)
Snigur, D. V.; Chebotarev, A. N.; Bevziuk, K. V.
2018-03-01
Colorimetry and spectrophotometry with chemometric data processing were used to study the acid-base properties of azo dyes in aqueous solution. The capabilities of both methods were compared. Ionization constants of all the functional groups of the azo compounds studied could be determined relative to the change in the specific color difference depending on the acidity of the medium. The colorimetric functions of ion-molecular forms of azo compounds used as an analytical signal allow us to obtain complete information on the acid-base equilibrium in a wide acidity range.
Effect of black point on accuracy of LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; He, Nannan; Ye, Yushan
2018-03-01
Black point is the point at which RGB's single channel digital drive value is 0. Due to the problem of light leakage of liquid-crystal displays (LCDs), black point's luminance value is not 0, this phenomenon bring some errors to colorimetric characterization of LCDs, especially low luminance value driving greater sampling effect. This paper describes the characteristic accuracy of polynomial model method and the effect of black point on accuracy, the color difference accuracy is given. When considering the black point in the characteristics equation, the maximum color difference is 3.246, the maximum color difference than without considering the black points reduced by 2.36. The experimental results show that the accuracy of LCDs colorimetric characterization can be improved, if the effect of black point is eliminated properly.
NASA Astrophysics Data System (ADS)
Dietrich, Nicolas; Hebrard, Gilles
2018-02-01
An approach for visualizing and measuring the mass transfer around a single bubble rising in a quiescent liquid is reported. A colorimetric technique, developed by (Dietrich et al. Chem Eng Sci 100:172-182, 2013) using an oxygen sensitive redox dye was implemented. It was based on the reduction of the colorimetric indicator in presence of oxygen, this reduction being catalysed by sodium hydroxide and glucose. In this study, resazurin was selected because it offered various reduced forms with colours ranging from transparent (without oxygen) to pink (in presence of oxygen). These advantages made it possible to visualize the spatio-temporal oxygen mass transfer around rising bubbles. Images were recorded by a CCD camera and, after post-processing, the shape, size, and velocity of the bubbles were measured and the colours around the bubbles mapped. A calibration, linking the level of colour with the dissolved oxygen concentration, enabled colour maps to be converted into oxygen concentration fields. A rheoscopic fluid was used to visualize the wake of the bubbles. A calculation method was also developed to determine the transferred oxygen fluxes around bubbles of two sizes (d = 0.82 mm and d = 2.12 mm) and the associated liquid-side mass transfer coefficients. The results compared satisfactorily with classical global measurements made by oxygen micro-sensors or from the classical models. This study thus constitutes a striking example of how this new colorimetric method could become a remarkable tool for exploring gas-liquid mass transfer in fluids.
NASA Astrophysics Data System (ADS)
Dietrich, Nicolas; Hebrard, Gilles
2018-07-01
An approach for visualizing and measuring the mass transfer around a single bubble rising in a quiescent liquid is reported. A colorimetric technique, developed by (Dietrich et al. Chem Eng Sci 100:172-182, 2013) using an oxygen sensitive redox dye was implemented. It was based on the reduction of the colorimetric indicator in presence of oxygen, this reduction being catalysed by sodium hydroxide and glucose. In this study, resazurin was selected because it offered various reduced forms with colours ranging from transparent (without oxygen) to pink (in presence of oxygen). These advantages made it possible to visualize the spatio-temporal oxygen mass transfer around rising bubbles. Images were recorded by a CCD camera and, after post-processing, the shape, size, and velocity of the bubbles were measured and the colours around the bubbles mapped. A calibration, linking the level of colour with the dissolved oxygen concentration, enabled colour maps to be converted into oxygen concentration fields. A rheoscopic fluid was used to visualize the wake of the bubbles. A calculation method was also developed to determine the transferred oxygen fluxes around bubbles of two sizes (d = 0.82 mm and d = 2.12 mm) and the associated liquid-side mass transfer coefficients. The results compared satisfactorily with classical global measurements made by oxygen micro-sensors or from the classical models. This study thus constitutes a striking example of how this new colorimetric method could become a remarkable tool for exploring gas-liquid mass transfer in fluids.
Dawson, V.K.; Meinertz, J.R.; Schmidt, L.J.; Gingerich, W.H.
2003-01-01
Concentrations of chloramine-T must be monitored during experimental treatments of fish when studying the effectiveness of the drug for controlling bacterial gill disease. A surrogate analytical method for analysis of chloramine-T to replace the existing high-performance liquid chromatography (HPLC) method is described. A surrogate method was needed because the existing HPLC method is expensive, requires a specialist to use, and is not generally available at fish hatcheries. Criteria for selection of a replacement method included ease of use, analysis time, cost, safety, sensitivity, accuracy, and precision. The most promising approach was to use the determination of chlorine concentrations as an indicator of chloramine-T. Of the currently available methods for analysis of chlorine, the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method best fit the established criteria. The surrogate method was evaluated under a variety of water quality conditions. Regression analysis of all DPD colorimetric analyses with the HPLC values produced a linear model (Y=0.9602 X+0.1259) with an r2 value of 0.9960. The average accuracy (percent recovery) of the DPD method relative to the HPLC method for the combined set of water quality data was 101.5%. The surrogate method was also evaluated with chloramine-T solutions that contained various concentrations of fish feed or selected densities of rainbow trout. When samples were analyzed within 2 h, the results of the surrogate method were consistent with those of the HPLC method. When samples with high concentrations of organic material were allowed to age more than 2 h before being analyzed, the DPD method seemed to be susceptible to interference, possibly from the development of other chloramine compounds. However, even after aging samples 6 h, the accuracy of the surrogate DPD method relative to the HPLC method was within the range of 80-120%. Based on the data comparing the two methods, the U.S. Food and Drug Administration has concluded that the DPD colorimetric method is appropriate to use to measure chloramine-T in water during pivotal efficacy trials designed to support the approval of chloramine-T for use in fish culture. ?? 2003 Elsevier Science B.V. All rights reserved.
Rapid Nanoprobe Signal Enhancement by In Situ Gold Nanoparticle Synthesis.
Dias, Jorge T; Svedberg, Gustav; Nystrand, Mats; Andersson-Svahn, Helene; Gantelius, Jesper
2018-03-07
The use of nanoprobes such as gold, silver, silica or iron-oxide nanoparticles as detection reagents in bioanalytical assays can enable high sensitivity and convenient colorimetric readout. However, high densities of nanoparticles are typically needed for detection. The available synthesis-based enhancement protocols are either limited to gold and silver nanoparticles or rely on precise enzymatic control and optimization. Here, we present a protocol to enhance the colorimetric readout of gold, silver, silica, and iron oxide nanoprobes. It was observed that the colorimetric signal can be improved by up to a 10000-fold factor. The basis for such signal enhancement strategies is the chemical reduction of Au 3+ to Au 0 . There are several chemical reactions that enable the reduction of Au 3+ to Au 0 . In the protocol, Good's buffers and H2O2 are used and it is possible to favor the deposition of Au 0 onto the surface of existing nanoprobes, in detriment of the formation of new gold nanoparticles. The protocol consists of the incubation of the microarray with a solution consisting of chloroauric acid and H2O2 in 2-(N-morpholino)ethanesulfonic acid pH 6 buffer following the nanoprobe-based detection assay. The enhancement solution can be applied to paper and glass-based sensors. Moreover, it can be used in commercially available immunoassays as demonstrated by the application of the method to a commercial allergen microarray. The signal development requires less than 5 min of incubation with the enhancement solution and the readout can be assessed by naked eye or low-end image acquisition devices such as a table-top scanner or a digital camera.
A sensitive gold nanoparticle-based colorimetric aptasensor for Staphylococcus aureus.
Yuan, Jinglei; Wu, Shijia; Duan, Nuo; Ma, Xiaoyuan; Xia, Yu; Chen, Jie; Ding, Zhansheng; Wang, Zhouping
2014-09-01
In this study, a gold nanoparticle-based colorimetric aptasensor for Staphylococcus aureus (S. aureus) using tyramine signal amplification (TSA) technology has been developed. First, the biotinylated aptamer specific for S. aureus was immobilized on the surface of the wells of the microtiter plate via biotin-avidin binding. Then, the target bacteria (S. aureus), biotinylated-aptamer-streptavidin-HRP conjugates, biotinylated tyramine, hydrogen peroxide and avidin-catalase were successively introduced into the wells of the microtiter plate. After that, the existing catalase consumed the hydrogen peroxide. Finally, the freshly prepared gold (III) chloride trihydrate was added, the color of the reaction production would be changed and the absorbance at 550 nm could be measured with a plate reader. Under optimized conditions, there was a linear relationship between the absorbance at 550 nm and the concentration of S. aureus over the range from 10 to 10(6) cfu mL(-1) (with an R² of 0.9947). The limit of the developed method was determined to be 9 cfu mL(-1). Copyright © 2014 Elsevier B.V. All rights reserved.
Pitfalls in the detection of cholesterol in Huntington's disease models.
Marullo, Manuela; Valenza, Marta; Leoni, Valerio; Caccia, Claudio; Scarlatti, Chiara; De Mario, Agnese; Zuccato, Chiara; Di Donato, Stefano; Carafoli, Ernesto; Cattaneo, Elena
2012-10-11
Background Abnormalities in brain cholesterol homeostasis have been reported in Huntington's disease (HD), an adult-onset neurodegenerative disorder caused by an expansion in the number of CAG repeats in the huntingtin (HTT) gene. However, the results have been contradictory with respect to whether cholesterol levels increase or decrease in HD models. Biochemical and mass spectrometry methods show reduced levels of cholesterol precursors and cholesterol in HD cells and in the brains of several HD animal models. Abnormal brain cholesterol homeostasis was also inferred from studies in HD patients. In contrast, colorimetric and enzymatic methods indicate cholesterol accumulation in HD cells and tissues. Here we used several methods to investigate cholesterol levels in cultured cells in the presence or absence of mutant HTT protein. Results Colorimetric and enzymatic methods with low sensitivity gave variable results, whereas results from a sensitive analytical method, gas chromatography-mass spectrometry, were more reliable. Sample preparation, high cell density and cell clonality also influenced the detection of intracellular cholesterol. Conclusions Detection of cholesterol in HD samples by colorimetric and enzymatic assays should be supplemented by detection using more sensitive analytical methods. Care must be taken to prepare the sample appropriately. By evaluating lathosterol levels using isotopic dilution mass spectrometry, we confirmed reduced cholesterol biosynthesis in knock-in cells expressing the polyQ mutation in a constitutive or inducible manner. *Correspondence should be addressed to Elena Cattaneo: elena.cattaneo@unimi.it.
A Schiff-based colorimetric fluorescent sensor with the potential for detection of fluoride ions.
Huang, Cheng-Yin; Wan, Chin-Feng; Chir, Jiun-Ly; Wu, An-Tai
2013-11-01
A simple Schiff-based colorimetric fluorescent receptor 1 was prepared. It exhibits a "turn-on-type" mode with high sensitivity in the presence of F(-). The change in color is very easily observed by the naked eye in the presence of F(-), whereas other anions do not induce such a change. Job plot indicated a 1:2 complexation stoichiometry between receptor 1 and F(-). The association constant for 1-F(-) in CH3CN was determined as 1.32*10(5) M(-2) by a Hill plot.
NASA Astrophysics Data System (ADS)
Alam, Md. Fazle; Laskar, Amaj Ahmed; Ahmed, Shahbaz; Shaida, Mohd. Azfar; Younus, Hina
2017-08-01
Melamine toxicity has recently attracted worldwide attention as it causes renal failure and the death of humans and animals. Therefore, developing a simple, fast and sensitive method for the routine detection of melamine is the need of the hour. Herein, we have developed a selective colorimetric method for the detection of melamine in milk samples based upon in-situ formation of silver nanoparticles (AgNPs) via tannic acid. The AgNPs thus formed were characterized by UV-Visible spectrophotometer, transmission electron microscope (TEM), zetasizer and dynamic light scattering (DLS). The AgNPs were used to detect melamine under in vitro condition and in raw milk spiked with melamine. Under optimal conditions, melamine could be selectively detected in vitro within the concentration range of 0.05-1.4 μM with a limit of detection (LOD) of 0.01 μM, which is lower than the strictest melamine safety requirement of 1 ppm. In spiked raw milk, the recovery percentage range was 99.5-106.5% for liquid milk and 98.5-105.5% for powdered milk. The present method shows extreme selectivity with no significant interference with other substances like urea, glucose, glycine, ascorbic acid etc. This assay method does not utilize organic cosolvents, enzymatic reactions, light sensitive dye molecules and sophisticated instrumentation, thereby overcoming some of the limitations of the other conventional methods.
NASA Astrophysics Data System (ADS)
Gao, Nan; Huang, Pengcheng; Wu, Fangying
2018-03-01
In this study, we have developed a method for rapid, highly efficient and selective detection of melamine. The negatively charged citrate ions form an electrostatic layer on gold nanoparticles (AuNPs) and keep the NPs dispersed and stable. When citrate-capped AuNPs were further modified with Triton X-100, it stabilized the AuNPs against the conditions of high ionic strength and a broad pH range. However, the addition of melamine caused the destabilization and aggregation of NPs. This may be attributed to the interaction between melamine and the AuNPs through the ligand exchange with citrate ions on the surface of AuNPs leading Triton X-100 to be removed. As a result, the AuNPs were unstable, resulting in the aggregation. The aggregation induced a wine red-to-blue color change, and a new absorption peak around 630 nm appeared. Triton X-100-AuNPs could selectively detect melamine at the concentration as low as 5.1 nM. This probe was successfully applied to detect melamine in milk. Furthermore, paper-based quantitative detection system using this colorimetric probe was also demonstrated by integrating with a smartphone.
Liu, Shufeng; Du, Zongfeng; Li, Peng; Li, Feng
2012-05-15
A facile, highly sensitive colorimetric strategy for dihydronicotinamide adenine dinucleotide (NADH) detection is proposed based on anti-aggregation of gold nanoparticles (AuNPs) via boronic acid-diol binding chemistry. The aggregation agent, 4-mercaptophenylboronic acid (MPBA), has specific affinity for AuNPs through Au-S interaction, leading to the aggregation of AuNPs by self-dehydration condensation at a certain concentration, which is responsible for a visible color change of AuNPs from wine red to blue. With the addition of NADH, MPBA would prefer reacting with NADH to form stable borate ester via boronic acid-diol binding dependent on the pH and solvent, revealing an obvious color change from blue to red with increasing the concentration of NADH. The anti-aggregation effect of NADH on AuNPs was seen by the naked eye and monitored by UV-vis extinction spectra. The linear range of the colorimetric sensor for NADH is from 8.0 × 10(-9)M to 8.0 × 10(-6)M, with a low detection limit of 2.0 nM. The as-established colorimetric strategy opened a new avenue for NADH determination. Copyright © 2012 Elsevier B.V. All rights reserved.
A simple and highly sensitive colorimetric detection method for gaseous formaldehyde.
Feng, Liang; Musto, Christopher J; Suslick, Kenneth S
2010-03-31
A colorimetric detection method using amine-functionalized polymer films doped with a pH indicator has been developed for the rapid, sensitive, and quantitative detection of gaseous formaldehyde at concentrations well below the immediately dangerous to life or health (IDLH) limit. In 1 min, visible color changes are easily observed, even down to the permissible exposure limit (PEL) at 750 ppb. The limit of detection is below 50 ppb (7% of the PEL) after 10 min of exposure. This sensor is essentially unaffected by changes in humidity or temperature (4 to 50 degrees C) and is not sensitive to common interferents.
NASA Astrophysics Data System (ADS)
Rohit, Jigneshkumar V.; Kailasa, Suresh Kumar
2014-11-01
We have developed a simple and rapid colorimetric method for on-site analysis of thiram and paraquat using cyclen dithiocarbamate-functionalized silver nanoparticles (CN-DTC-Ag NPs) as a colorimetric probe. The synthesized CN-DTC-Ag NPs were characterized by UV-Visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy, dynamic light scattering, and transmission electron microscopic techniques. The CN-DTC molecules provide good supramolecular self assembly on the surfaces of Ag NPs to encapsulate thiram and paraquat selectively via "host-guest" chemistry, resulting in red-shift in surface plasmon resonance peak of CN-DTC-Ag NPs from 396 to 530 nm and 510 nm and color change from yellow to pink for thiram and to orange for paraquat, which can be naked-eye detected. The present method shows good linearity in the range of 10.0-20.0 µM and of 50.0-250 µM with limits of detection 2.81 × 10-6 M and 7.21 × 10-6 M for thiram and paraquat, respectively. This method was proved as a promising tool for on-site and real-time monitoring of thiram and paraquat in environmental water, potato, and wheat samples.
Yang, Zhenghao; Liu, Zhipeng; Chen, Yuncong; Wang, Xiaoqing; He, Weijiang; Lu, Yi
2012-07-14
A hybrid coumarin-hemicyanine dye, Cou-BT, was developed as a new ratiometric and colorimetric sensor for cyanide with a sensing mechanism via nucleophilic addition of cyanide anion to the benzothiolium group. Cou-BT shows high sensitivity and selectivity for cyanide detection over other common anion species in aqueous acetonitrile solution. The calculated pseudo-first-order rate constant for cyanide anion addition was (2.13 ± 0.08) × 10(-2) s(-1) at 298 K, and the detection limit was estimated to be 0.64 μM. The DFT and TDDFT calculation results suggest that the ratiometric and colorimetric sensing behavior of Cou-BT upon its reaction with cyanide was due to the interrupted π-conjugation and blocked ICT progress.
Mandal, Shreya; Patra, Arpita; Samanta, Animesh; Roy, Suchismita; Mandal, Arpita; Mahapatra, Tapasi Das; Pradhan, Shrabani; Das, Koushik; Nandi, Dilip Kumar
2013-12-01
To investigate phytochemical screening, antimicrobial activity and qualitative thin layer chromatographic separation of flavonoid components, antioxidant activity and total flavonoid compound of Terminalia arjuna. For phytochemical screening, some common and available standard tests were done. Antimicrobial bioassay was done through agar well diffusion method. Detection of antioxidant activity and flavonoid compounds were done through thin layer chromatography. Total antioxidant activity was measured by 2, 2-diphenyl-1-picrylhydrazyl (DPPH) in colorimetric method. Aluminum chloride colorimetric method was used for total flavonoid determination. Phytochemical screening showed the active compounds presence in high concentration, such as phytosterol, lactones, flavonoids, phenolic compounds and tannins and glycosides. The antimicrobial activity of extract showed that greater inhibition zone against Gram negative bacteria than Gram positive bacteria. This methanolic extract showed a promising antioxidant activity, as absorption of DPPH redicles decreased in DPPH free radical scavenging assay. Flavonoids components having antioxidant property present in the methanol extract at a level of 199.00 mg quercetin equivalent/g of dried methanol extract in colorimetric method. The Terminalia arjuna bark extract revealed the presence of bio-active constituents which are known to exhibit medicinal as well as physiological activities. Copyright © 2013 Asian Pacific Tropical Biomedical Magazine. Published by Elsevier B.V. All rights reserved.
[Research on the designing method of a special shade guide for tooth whitening].
Xu, Yingxin
2015-10-01
To investigate a method of designing an accurate and scientific shade guide, especially used for judging the effect of tooth whitening, by analyzing the colorimetric values of discolored teeth statistically. One hundred thirty-six pictures of patients who had been receiving the Beyond cold light whitening treatment from February 2009 to July 2014 were analyzed, including 25 tetracycline teeth, 61 mottled-enamel teeth, and 50 yellow teeth. The colorimetric values of discolored teeth were measured. The L* values of shade tabs were calculated by hierarchical clustering of those of discolored teeth. The a* and b* values of shade tabs were the mean of those observed for discolored teeth. Accordingly, different shade guides were designed for each type of discolored teeth, and the effects were evaluated. A statistically significant difference in colorimetric values was found among the three types of discolored teeth. Compared with the Vitapan Classical shade guide, the shade guides designed through the present method were more scientific and accurate in judging the effect of tooth whitening. Moreover, the arrangement of shade tabs was more logical, and the color difference between shade tabs and discolored teeth was smaller. The proposed designing method is theoretically feasible, although its clinical effect has yet to be proven.
Levent, Abdulkadir; Sentürk, Zühre
2010-09-01
Colorimetric and atomic absorption spectrometric methods have been developed for the determination of mucolytic drug Ambroxol. These procedures depend upon the reaction of iron(III) metal ion with the drug in the presence of thiocyanate ion to form stable ion-pair complex which extractable chloroform. The red-coloured complex was determined either colorimetrically at 510 nm or by indirect atomic absorption spectrometry (AAS) via the determination of the iron content in the formed complex. The optimum experimental conditions for pH, concentrations of Fe(3+) and SCN(-), shaking time, phase ratio, and the number of extractions were determined. Under the proposed conditions, linearity was obeyed in the concentration ranges 4.1x10(-6) - 5.7x10(-5) M (1.7-23.6 µg mL(-1)) using both methods, with detection limits of 4.6x10(-7) M (0.19 µg mL(-1)) for colorimetry and 1.1x10(-6) M (0.46 µg mL(-1)) for AAS. The proposed methods were applied for the determination of Ambroxol in tablet dosage forms. The results obtained were statistically analyzed and compared with those obtained by applying the high-performance liquid chromatographic method with diode-array detection.
Xu, Yunbo; Dong, Yangjun; Jiang, Xue; Zhu, Ningning
2013-10-01
This study describes a simple and highly selective method for the colorimetric detection of trivalent chromium (Cr3+) using tartrate-capped silver nanoparticles (AgNPs) as probe. The addition of tartrate to the initially prepared AgNPs gives tartrate-stabilized AgNPs ascribing to the electrostatic repulsion of the highly negatively charged tartrate ions covered on the surface of AgNPs. It is found that, in the presence of Cr3+ in aqueous solution, the aggregation of tartrate-stabilized AgNPs occurs. The color of AgNPs suspension changes from yellow to pink and the surface plasmon absorption band broadens and red shifts, which could be applied for the colorimetric detection of Cr3+ in aqueous solution. The utilization of tartrate-stabilized AgNPs as probe substantially increases the selectivity and sensitivity for colorimetric detection of Cr3+. Control experiments with the addition of over 14 other metal ions, such as Pb2+, Zn2+, Cr2O7(2-), Cd2+, Co2+, Cu2+, Al3+, Ni2+, Mn2+, Ba2+, Fe3+, Ca2+, Mg2+, Sr+ do not result in a distinct change in the color or in the spectrum of the suspension, indicating that these metal ions do not interfere with the colorimetric detection of Cr3+. Under the conditions employed here, A502/A393 (ratio of absorption value at 502 nm to 393 nm) is linear with the concentration of Cr3+ within a concentration range from 0.1 to 1.17 microM with a detection limit of 0.06 microM. This study may offer a simple, rapid and sensitive approach to colorimetric detection of Cr3+ in aqueous solution.
Jahn, B; Stüben, A; Bhakdi, S
1996-01-01
Two colorimetric methods that use Alamar Blue or 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) for assaying the in vitro activities of antifungal agents have been described. We report that both tests performed similarly when the antifungal activity of amphotericin B against Candida albicans was determined. However, only the MTT test generated interpretable data when Aspergillus fumigatus was used. PMID:8818910
Chen, Yuan; Fu, Qiangqiang; Li, Dagang; Xie, Jun; Ke, Dongxu; Song, Qifang; Tang, Yong; Wang, Hong
2017-11-01
Smartphone biosensors could be cost-effective, portable instruments to be used for the readout of liquid colorimetric assays. However, current reported smartphone colorimetric readers have relied on photos of liquid assays captured using a camera, and then analyzed using software programs. This approach results in a relatively low accuracy and low generality. In this work, we reported a novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays. The portable and low-cost ($0.15) reader utilized a simplified electronic and light path design. Furthermore, our reported smartphone colorimetric reader can be compatible with different smartphones. As a proof of principle, the utility of this device was demonstrated using it in conjunction with an enzyme-linked immunosorbent assay to detect zearalenone. Results were consistent with those obtained using a professional microplate reader. The developed smartphone colorimetric reader was capable of providing scalable, cost-effective, and accurate results for liquid colorimetric assays that related to clinical diagnoses, environment pollution, and food testing. Graphical abstract A novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays.
NASA Astrophysics Data System (ADS)
Liang, Lijiao; Zhen, Shujun; Huang, Chengzhi
2017-02-01
A highly selective method was presented for colorimetric determination of melamine using uracil 5‧-triphosphate sodium modified gold nanoparticles (UTP-Au NPs) in this paper. Specific hydrogen-bonding interaction between uracil base (U) and melamine resulted in the aggregation of AuNPs, displaying variations of localized surface plasmon resonance (LSPR) features such as color change from red to blue and enhanced localized surface plasmon resonance light scattering (LSPR-LS) signals. Accordingly, the concentration of melamine could be quantified based on naked eye or a spectrometric method. This method was simple, inexpensive, environmental friendly and highly selective, which has been successfully used for the detection of melamine in pretreated liquid milk products with high recoveries.
An improved method for LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; Wang, Qiaojie; He, Nannan; Ye, Yushan
2018-03-01
The colorimetric characterization of the display can achieve the purpose of precisely controlling the color of the monitor. This paper describes an improved method for estimating the gamma value of liquid-crystal displays (LCDs) without using a measurement device was described by Xiao et al. It relies on observer's luminance matching by presenting eight half-tone patterns with luminance from 1/9 to 8/9 of the maximum value of each color channel. Since the previous method lacked partial low frequency information, we partially replaced the half-tone patterns. A large number of experiments show that the color difference is reduced from 3.726 to 2.835, and our half-tone pattern can better estimate the visual gamma value of LCDs.
Colour change evaluation on UV radiation exposure for Păun-Repedea calcareous geomaterial
NASA Astrophysics Data System (ADS)
Pelin, V.; Sandu, I.; Munteanu, M.; Iurcovschi, C. T.; Gurlui, S.; Sandu, AV; Vasilache, V.; Brȃnzilă, M.; Sandu, I. G.
2016-06-01
When talking about the preservation treatments that can be applied to natural stones used in different constructions, the surface hydrophobization plays an important part, especially when referring to porous surfaces like the calcareous oolithic stones specific to Repedea area, Iasi County, Romania. The present paper presents a method that evaluates the hydrophobization efficiency of two types of pellicles, involving UV artificial ageing and colorimetric analysis of the treated surfaces. The evaluation was done through continuous colorimetric monitoring and by comparing the evolution of the chromatic modifications of the two treated surfaces with the original colorimetric values and with the witness area, which was exposed to UV radiations under the same conditions, but left chemical untreated. The techniques used during this experiment were: CIE L*a*b* colorimetry, OM, SEM-EDX, UV radiation exposure and Spectrum Irradiance Measurement.
Ozdemir Olgun, F Ayca; Üzer, Ayşem; Ozturk, Birsen Demirata; Apak, Reşat
2018-05-15
Antioxidant activity (AOA) assays using nanotechnology are recently developed utilizing nanoparticles of transition metal oxides, especially nanoceria that can switch between trivalent and tetravalent oxidation states of cerium. Cerium oxide nanoparticles (CeO-NPs) may act as both an oxidant and an antioxidant, depending on the preparation method and particle size. A novel colorimetric sensor for AOA assay is proposed with the use of poly(acrylic acid) sodium salt (PAANa)-coated CeO-NPs. PAANa-coated CeO-NPs oxidized tetramethyl benzidine (TMB), a peroxidase substrate, in a slightly acidic solution at pH 4.0 to a blue charge-transfer complex. Antioxidants decreased the color intensity of the nanoceria suspension, and were indirectly determined by absorbance difference. Detection limits, linearity, additivity and precision were calculated, e.g., quercetin quantification with the proposed assay showed a detection limit of 8.25 × 10 -9 mol L -1 . The trolox equivalent antioxidant capacities of hydrophilic and lipophilic antioxidants were compatible with those of conventional antioxidant assays. Potential interferents such as glucose, citric acid, mannitol, sorbitol and benzoic acid did not adversely affect AOA determination. The developed sensor is more sensitive and selective than similar colorimetric sensors relying on the intrinsic color change of nanoceria. The measurement wavelength is sufficiently red-shifted, preventing possible interferences from plant pigments. Copyright © 2018 Elsevier B.V. All rights reserved.
Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test.
Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Thyssen, Jacob P
2015-11-01
Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release at 0.5 ppm without interference from other pure metals, alloys, or leather. A market survey using the test showed no chromium(VI) release from work tools (0/100). However, chromium(VI) release from metal screws (7/60), one earring (1/50), leather shoes (4/100) and leather gloves (6/11) was observed. We found no false-positive test reactions. Confirmatory testing was performed with X-ray fluorescence (XRF) and spectrophotometrically on extraction fluids. The use of DPC as a colorimetric spot test reagent appears to be a good and valid test method for detecting the release of chromium(VI) ions from leather and metal articles. The spot test has the potential to become a valuable screening tool. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kim, Hyunsu; Swamy, K M K; Kwon, Nahyun; Kim, Yonghee; Park, Sungsu; Yoon, Juyoung
2017-07-05
A phenolphthalein-based colorimetric probe bearing a dinitrobenzene group is reported as a thiophenol (PhSH)-selective chemodosimeter. PhSH can react with chemodosimeter 1 to afford phenolphthalein. The addition of PhSH to the aqueous solution of 1 followed by a change in pH of the resulting solution to basic induces a selective color change from colorless to pink. Furthermore, using PhSH and base as inputs and color change of 1 by naked eye as an output, leads to the construction of an AND logic gate. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Estimation of reflectance from camera responses by the regularized local linear model.
Zhang, Wei-Feng; Tang, Gongguo; Dai, Dao-Qing; Nehorai, Arye
2011-10-01
Because of the limited approximation capability of using fixed basis functions, the performance of reflectance estimation obtained by traditional linear models will not be optimal. We propose an approach based on the regularized local linear model. Our approach performs efficiently and knowledge of the spectral power distribution of the illuminant and the spectral sensitivities of the camera is not needed. Experimental results show that the proposed method performs better than some well-known methods in terms of both reflectance error and colorimetric error. © 2011 Optical Society of America
NASA Astrophysics Data System (ADS)
Ugolnikov, Oleg S.; Maslov, Igor A.
2018-03-01
Polarization measurements of the twilight background with Wide-Angle Polarization Camera (WAPC) are used to detect the depolarization effect caused by stratospheric aerosol near the altitude of 20 km. Based on a number of observations in central Russia in spring and summer 2016, we found the parameters of lognormal size distribution of aerosol particles. This confirmed the previously published results of the colorimetric method as applied to the same twilights. The mean particle radius (about 0.1 micrometers) and size distribution are also in agreement with the recent data of in situ and space-based remote sensing of stratospheric aerosol. Methods considered here provide two independent techniques of the stratospheric aerosol study based on the twilight sky analysis.
NASA Astrophysics Data System (ADS)
R. S., Aparna; J. S., Anjali Devi; John, Nebu; Abha, K.; S. S., Syamchand; George, Sony
2018-06-01
Hurdles to develop point of care diagnostic methods restrict the translation of progress in the health care sector from bench side to bedside. In this article a simple, cost effective fluorescent as well as colorimetric nanosensor was developed for the early and easy detection of hyperbilirubinemia. A stable, water soluble bovine serum albumin stabilised copper nanocluster (BSA CuNC) was used as the fluorescent probe which exhibited strong blue emission (404 nm) upon 330 nm excitation. The fluorescence of the BSA CuNC can be effectively quenched by the addition of bilirubin by the formation of copper-bilirubin complex. Meanwhile the copper-bilirubin complex resulted in an observable colour change from pale violet to green facilitating colorimetric detection. The prepared sensor displayed good selectivity and sensitivity over other co-existing molecules, and can be used for quantifying bilirubin with a detection limit down to 257 fM. Additionally, the as-prepared probe was coated on a paper strip to develop a portable paper strip sensor of bilirubin. Moreover, the method was successfully applied in real sample analysis and obtained promising result.
Tao, Yu; Lin, Youhui; Huang, Zhenzhen; Ren, Jinsong; Qu, Xiaogang
2012-01-15
An easy prepared fluorescence turn-on and colorimetric dual channel probe was developed for rapid assay of Hg(2+) ions with high sensitivity and selectivity by using poly(acrylic acid)-templated silver nanoclusters (PAA-AgNCs). The PAA-AgNCs exhibited weak fluorescence, while upon the addition of Hg(2+) ions, AgNCs gives a dramatic increase in fluorescence as a result of the changes of the AgNCs states. The detection limit was estimated to be 2 nM, which is much lower than the Hg(2+) detection requirement for drinking water of U.S. Environmental Protection Agency, and the turn-on sensing mode offers additional advantage to efficiently reduce background noise. Also, a colorimetric assay of Hg(2+) ions can be realized due to the observed absorbance changes of the AgNCs. More importantly, the method was successfully applied to the determination of Hg(2+) ions in real water samples, which suggests our proposed method has a great potential of application in environmental monitoring. Copyright © 2011 Elsevier B.V. All rights reserved.
Metal oxide based multisensor array and portable database for field analysis of antioxidants
Sharpe, Erica; Bradley, Ryan; Frasco, Thalia; Jayathilaka, Dilhani; Marsh, Amanda; Andreescu, Silvana
2014-01-01
We report a novel chemical sensing array based on metal oxide nanoparticles as a portable and inexpensive paper-based colorimetric method for polyphenol detection and field characterization of antioxidant containing samples. Multiple metal oxide nanoparticles with various polyphenol binding properties were used as active sensing materials to develop the sensor array and establish a database of polyphenol standards that include epigallocatechin gallate, gallic acid, resveratrol, and Trolox among others. Unique charge-transfer complexes are formed between each polyphenol and each metal oxide on the surface of individual sensors in the array, creating distinct optically detectable signals which have been quantified and logged into a reference database for polyphenol identification. The field-portable Pantone/X-Rite© CapSure® color reader was used to create this database and to facilitate rapid colorimetric analysis. The use of multiple metal-oxide sensors allows for cross-validation of results and increases accuracy of analysis. The database has enabled successful identification and quantification of antioxidant constituents within real botanical extractions including green tea. Formation of charge-transfer complexes is also correlated with antioxidant activity exhibiting electron transfer capabilities of each polyphenol. The antioxidant activity of each sample was calculated and validated against the oxygen radical absorbance capacity (ORAC) assay showing good comparability. The results indicate that this method can be successfully used for a more comprehensive analysis of antioxidant containing samples as compared to conventional methods. This technology can greatly simplify investigations into plant phenolics and make possible the on-site determination of antioxidant composition and activity in remote locations. PMID:24610993
Enhanced DNA Sensing via Catalytic Aggregation of Gold Nanoparticles
Huttanus, Herbert M.; Graugnard, Elton; Yurke, Bernard; Knowlton, William B.; Kuang, Wan; Hughes, William L.; Lee, Jeunghoon
2014-01-01
A catalytic colorimetric detection scheme that incorporates a DNA-based hybridization chain reaction into gold nanoparticles was designed and tested. While direct aggregation forms an inter-particle linkage from only ones target DNA strand, the catalytic aggregation forms multiple linkages from a single target DNA strand. Gold nanoparticles were functionalized with thiol-modified DNA strands capable of undergoing hybridization chain reactions. The changes in their absorption spectra were measured at different times and target concentrations and compared against direct aggregation. Catalytic aggregation showed a multifold increase in sensitivity at low target concentrations when compared to direct aggregation. Gel electrophoresis was performed to compare DNA hybridization reactions in catalytic and direct aggregation schemes, and the product formation was confirmed in the catalytic aggregation scheme at low levels of target concentrations. The catalytic aggregation scheme also showed high target specificity. This application of a DNA reaction network to gold nanoparticle-based colorimetric detection enables highly-sensitive, field-deployable, colorimetric readout systems capable of detecting a variety of biomolecules. PMID:23891867
NASA Astrophysics Data System (ADS)
Liu, Juewen; Lu, Yi
This chapter reviews recent progress in the interface between functional nucleic acids and nanoscale science and technology, and its analytical applications. In particular, the use of metallic nanoparticles as the color reporting groups for the action (binding, catalysis, or both) of aptamers, DNAzymes, and aptazymes is described in detail. Because metallic nanoparticles possess high extinction coefficients and distance-dependent optical properties, they allow highly sensitive detections with minimal consumption of materials. The combination of quantum dots (QDs) with functional nucleic acids as fluorescent sensors is also described. The chapter starts with the design of colorimetric and fluorescent sensors responsive to single analytes, followed by sensors responsive to multiple analytes with controllable cooperativity and multiplex detection using both colorimetric and fluorescent signals in one pot, and ends by transferring solution-based detections into litmus paper type of tests, making them generally applicable and usable for a wide range of on-site and real-time analytical applications such as household tests, environmental monitoring, and clinical diagnostics.
Liu, Jia-Ming; Wang, Xin-Xing; Jiao, Li; Cui, Ma-Lin; Lin, Li-Ping; Zhang, Li-Hong; Jiang, Shu-Lian
2013-11-15
Fe(3+) can catalyze H2O2 to oxidize along on the longitudinal axis of gold nanorods (AuNRs), which caused the aspect ratio of AuNRs to decrease, longitudinal plasmon absorption band (LPAB) of AuNRs to blueshift (Δλ) and the color of the solution to change obviously. Thus, a rapid response and highly sensitive non-aggregation colorimetric sensor for the determination of Fe(3+) has been developed based on the signal amplification effect of catalyzing H2O2 to oxidize AuNRs. This simple and selective sensor with a wide linear range of 0.20-30.00 μM has been utilized to detect Fe(3+) in blood samples, and the results consisted with those obtained by inductively coupled plasma-mass spectroscopy (ICP-MS). Simultaneously, the mechanism of colorimetric sensor for the detection of Fe(3+) was also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Sukato, Rangsarit; Sangpetch, Nuanphan; Palaga, Tanapat; Jantra, Suthikorn; Vchirawongkwin, Viwat; Jongwohan, Chanantida; Sukwattanasinitt, Mongkol; Wacharasindhu, Sumrit
2016-08-15
Development of cyanide sensor is important as the anion is harmful to human health and the environment. Herein, a new colorimetric and fluorescent probe GSB based on boron dipyrrole-methene (BODIPY) containing salicylaldehyde group for cyanide detection has been reported. GSB undergoes exclusive colorimetric change from orange to colorless and exhibits selective fluorescence turn-on at 504nm upon the addition of cyanide. Other 13 anions give almost no interference under physiological condition. Detection limit of the new cyanide-sensing GSB is 0.88μM, which is below World Health Organization (WHO) recommended level in drinking water. A calculation by density functional theory (DFT) shows suppression of photoinduced electron transfer (PET) mechanism along with the interruption of π-conjugation between salicylaldehyde and BODIPY core by cyanide anion. Cell imaging studies demonstrated that GSB is compatible and capable of sensing cyanide anion in living cells. Copyright © 2016 Elsevier B.V. All rights reserved.
Kumar, Jutika; Bhattacharyya, Pradip K; Das, Diganta Kumar
2015-03-05
Schiff base derived from naphthylamine and benzil (L) binds to two Cu(2+) ions, one by coordination through N of the Schiff base and another by pi cation interaction through benzil rings. This bonding pattern determined by DFT calculation has been proved by matching electronic spectrum obtained from TDDFT calculation to the experimental one. L acts as "on-off" fluorescent and bare eye detectable colorimetric (purple color) sensor for Cu(2+) ion over the metal ions - Na(+), K(+), Ca(2+) Mn(2+), Co(2+) Ni(2+), Zn(2+), Pb(2+), Cd(2+), Hg(2+), Ag(+), Hg(2+) and Al(3+) in 1:1 v/v CH3CN:H2O. These metal ions do not interfere the fluorescent/colorimetric sensing. As fluorescent sensor the linear range of detection is 5×10(-5) to 3×10(-4)M and detection limit 10(-5)M. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kumar, Jutika; Bhattacharyya, Pradip K.; Das, Diganta Kumar
2015-03-01
Schiff base derived from naphthylamine and benzil (L) binds to two Cu2+ ions, one by coordination through N of the Schiff base and another by pi cation interaction through benzil rings. This bonding pattern determined by DFT calculation has been proved by matching electronic spectrum obtained from TDDFT calculation to the experimental one. L acts as "on-off" fluorescent and bare eye detectable colorimetric (purple color) sensor for Cu2+ ion over the metal ions - Na+, K+, Ca2+ Mn2+, Co2+ Ni2+, Zn2+, Pb2+, Cd2+, Hg2+, Ag+, Hg2+ and Al3+ in 1:1 v/v CH3CN:H2O. These metal ions do not interfere the fluorescent/colorimetric sensing. As fluorescent sensor the linear range of detection is 5 × 10-5 to 3 × 10-4 M and detection limit 10-5 M.
Zhang, Shanshan; Sun, Tao; Xiao, Dejun; Yuan, Fang; Li, Tianduo; Wang, Enhua; Liu, Haixia; Niu, Qingfen
2018-01-15
A novel dual-responsive colorimetric and fluorescent chemosensor L based on diketopyrrolopyrrole derivative for Fe 3+ detection was designed and synthesized. In presence of Fe 3+ , sensor L displayed strong colorimetric response as amaranth to rose pink and significant fluorescence enhancement and chromogenic change, which served as a naked-eye indicator by an obvious color change from purple to red. The binding constant for L-Fe 3+ complex was found as 2.4×10 4 with the lower detection limit of 14.3nM. The sensing mechanism was investigated in detail by fluorescence measurements, IR and 1 H NMR spectra. Sensor L for Fe 3+ detection also exhibited high anti-interference performance, good reversibility, wide pH response range and instantaneous response time. Furthermore, the sensor L has been used to quantify Fe 3+ ions in practical water samples with good recovery. Copyright © 2017 Elsevier B.V. All rights reserved.
Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L
2018-01-01
The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Projector primary-based optimization for superimposed projection mappings
NASA Astrophysics Data System (ADS)
Ahmed, Bilal; Lee, Jong Hun; Lee, Yong Yi; Lee, Kwan H.
2018-01-01
Recently, many researchers have focused on fully overlapping projections for three-dimensional (3-D) projection mapping systems but reproducing a high-quality appearance using this technology still remains a challenge. On top of existing color compensation-based methods, much effort is still required to faithfully reproduce an appearance that is free from artifacts, colorimetric inconsistencies, and inappropriate illuminance over the 3-D projection surface. According to our observation, this is due to the fact that overlapping projections are treated as an additive-linear mixture of color. However, this is not the case according to our elaborated observations. We propose a method that enables us to use high-quality appearance data that are measured from original objects and regenerate the same appearance by projecting optimized images using multiple projectors, ensuring that the projection-rendered results look visually close to the real object. We prepare our target appearances by photographing original objects. Then, using calibrated projector-camera pairs, we compensate for missing geometric correspondences to make our method robust against noise. The heart of our method is a target appearance-driven adaptive sampling of the projection surface followed by a representation of overlapping projections in terms of the projector-primary response. This gives off projector-primary weights to facilitate blending and the system is applied with constraints. These samples are used to populate a light transport-based system. Then, the system is solved minimizing the error to get the projection images in a noise-free manner by utilizing intersample overlaps. We ensure that we make the best utilization of available hardware resources to recreate projection mapped appearances that look as close to the original object as possible. Our experimental results show compelling results in terms of visual similarity and colorimetric error.
Hong, Wooyoung; Lee, Sooyeon; Cho, Youngnam
2016-12-15
We developed a nanoroughened, biotin-doped polypyrrole immunosensor for the detection of tumor markers through dual-signal (electrochemical and colorimetric) channels, electrochemical and colorimetric, that demonstrates remarkable analytical performance. A rapid, one-step electric field-mediated method was employed to fabricate the immunosensor with nanoscale roughness by simply modulating the applied electrical potential. We demonstrated the successful detection of three tumor markers (CA125, CEA, and PSA) via the double enzymatic signal amplifications in the presence of a target antigen, ultimately leading to desired diagnostic accuracy and reliability. The addition of multiple horseradish peroxidase (HRP)- and antibody-labeled nanoparticles greatly amplified the signal and simplified the measurement of cancer biomarker proteins by sequentially magnifying electrochemical and colorimetric signals in a single platform. The two parallel assays performed using the proposed immunosensor have yielded highly consistent and reproducible results. Additionally, for the analysis of plasma samples in a clinical setting, the values obtained with our immunosensor were validated by correlating the results with those of a standard radioimmunoassay (RIA), which obtained very similar clinically valid responses. Copyright © 2016 Elsevier B.V. All rights reserved.
Kai, Yumei; Hu, Yonghong; Wang, Kai; Zhi, Wenbiao; Liang, Mengmeng; Yang, Wenge
2014-01-24
A high selective colorimetric and ratiometric fluorescent probe based on 4-hydroxy-1, 8-naphthalimide was designed and synthesized to detect fluoride ions (F(-)). The sensing behavior of this probe was studied by UV-visible and fluorescence spectroscopy. The probe displays an 110 nm red-shift of fluorescence emission and the color changes from colorless to yellow by virtue of the strong affinity of F(-) toward silicon which can act as a new visual sensor for F(-). Copyright © 2013 Elsevier B.V. All rights reserved.
A colorimetric and ratiometric fluorescent chemosensor for fluoride based on proton transfer.
Jia, Chuandong; Wu, Biao; Liang, Jianjun; Huang, Xiaojuan; Yang, Xiao-Juan
2010-01-01
N-Phenyl-N'-(3-quinolinyl)urea (1) has been developed as a highly selective colorimetric and ratiometric fluorescent chemosensor for fluoride ion based on a proton transfer mechanism. Evidences for the mechanism were provided by UV-vis and fluorescence titration and especially (1)H and (19)F NMR experiments. The sensor gave the largest ratiometric fluorescent response reported so far (R(max)/R(min) = 2620) to fluoride. Taking H(+) as the "recovering reagent", the sensor can be reversibly "used" and "recovered" for several cycles with only a slight decay of the response ability.
NASA Astrophysics Data System (ADS)
Zhao, Baoying; Yang, Binsheng; Hu, Xiangquan; Liu, Bin
2018-06-01
Aggregation-induced emission (AIE) active fluorescent probes have attracted great potential in biological sensors. In this paper two cyanostilbene based fluorescence chemoprobe Cya-NO2 (1) and Cya-N3 (2) were developed and evaluated for the selective and sensitive detection of hydrogen sulfide (H2S). Both of these probes behave aggression-induced emission (AIE) activity which fluoresces in the red region with a large Stokes shift. They exhibit rapid response to H2S with enormous colorimetric and ratiometric fluorescent changes. They are readily employed for assessing intracellular H2S levels.
NASA Astrophysics Data System (ADS)
Pei, Peng-Xiang; Hu, Jing-Han; Long, Chen; Ni, Peng-Wei
2018-06-01
A novel chemosensor 2-((Z)-(((E)-quinolin-2-ylmethylene)hydrazono)methyl)phenol PX has been successfully designed and synthesized, which showed both colorimetric and "turn-on" fluorescence responses for CN- in DMSO/H2O (3:2, v/v; pH = 7.20) solution. The sensor could respond effectively to the stimulation of CN- ions via deprotonation and sensing mechanism of intramolecular charge transfer (ICT). Moreover, the sensor PX was successfully utilized to detect CN- in bitter almond, and the detection limit on fluorescence response of PX towards CN- was down to 4.5 × 10-7 M. Test strips containing PX were also prepared, which could act as a practical colorimetric tool to detect CN- in aqueous media.
[Detection of viable metabolically active yeast cells using a colorimetric assay].
Růzicka, F; Holá, V
2008-02-01
The increasing concern of yeasts able to form biofilm brings about the need for susceptibility testing of both planktonic and biofilm cells. Detection of viability or metabolic activity of yeast cells after exposure to antimicrobials plays a key role in the assessment of susceptibility testing results. Colorimetric assays based on the color change of the medium in the presence of metabolically active cells proved suitable for this purpose. In this study, the usability of a colorimetric assay with the resazurin redox indicator for monitoring the effect of yeast inoculum density on the reduction rate was tested. As correlation between the color change rate and inoculum density was observed, approximate quantification of viable cells was possible. The assay would be of relevance to antifungal susceptibility testing in both planktonic and biofilm yeasts.
Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin
2010-01-01
In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was flown and deployed as a Station Development Test Objective (SDTO) experiment on the ISS. The goal of the SDTO experiment is to evaluate the acceptability of CSPE technology for routine water quality monitoring on the ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on the ISS. The initial results obtained from the SDTO experiment are also reported and discussed in detail
NASA Astrophysics Data System (ADS)
Liu, Zhaodi; Xu, Huajie; Sheng, Liangquan; Chen, Shuisheng; Huang, Deqian; Liu, Jie
2016-03-01
A colorimetric and fluorescent chemosensor (L) for Al(III) was synthesized and fully characterized. L could be both used as a colorimetric and fluorescent chemosensor for the detection of Al3 + ions with low detection limit (8.87 × 10- 7 M) in CH3CN-H2O (1:1, v/v) solution. The binding ratio of L-Al3 + was determined from the Job plot (absorption and fluorescence spectra) and MALDI-TOF MS data to be 1:1. The binding constant (Ka) of Al3 + binding to L was calculated to be 4.8 × 105 M- 1 from a Benesi-Hildebrand plot. Moreover, the binding site of L with Al3 + was determined by 1H NMR titration experiment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, H.B.; Desai, S.R.; Nadkarni, M.N.
1961-01-01
A procedure has been standardized for the determination of boron in cokes, pitches, and graphites. The method consists of fixing the boron present in the sample as calcium borate, ion-exchange separation of boric acid from the associated cations, and the colorimetric determination of boron using the curcumin-trichloracetic acid method. Sulfur which is usually present in pitches and cokes is expected to be oxidized to sulfate during the fixation of boron and hence its effect on the colorimetry has been studied. Application of the procedure to the determination of 0.50 and 1.00 microgram amounts of boron, has given coefficients of variationmore » of l0.0 and 6.7% respectively. (auth)« less
Evaluation of a colorimetric reagent strip assay for urine specific gravity.
Kirschbaum, B B
1983-06-01
N-Multistix SG provides a convenient colorimetric assay for the determination of the specific gravity (sp. gr.) of freshly voided urine. When compared with results obtained by standard hydrometry, the colorimetric assay sp. gr. was observed to decrease by as much as 0.010 units as urine pH increased from 5 to 7. Moderate levels of proteinuria that did not alter hydrometer readings effectively raised the colorimetric sp. gr. by 0.005-0.010 units. The colorimetric assay was almost completely insensitive to clinically encountered concentrations of glucose and urea but responded appropriately to monovalent salts. The magnitude of these observed discrepancies places serious limitations on the value of the colorimetric sp. gr. measurement.
Pitfalls in the detection of cholesterol in Huntington’s disease models
Marullo, Manuela; Valenza, Marta; Leoni, Valerio; Caccia, Claudio; Scarlatti, Chiara; De Mario, Agnese; Zuccato, Chiara; Di Donato, Stefano; Carafoli, Ernesto; Cattaneo, Elena
2012-01-01
Background Abnormalities in brain cholesterol homeostasis have been reported in Huntington’s disease (HD), an adult-onset neurodegenerative disorder caused by an expansion in the number of CAG repeats in the huntingtin (HTT) gene. However, the results have been contradictory with respect to whether cholesterol levels increase or decrease in HD models. Biochemical and mass spectrometry methods show reduced levels of cholesterol precursors and cholesterol in HD cells and in the brains of several HD animal models. Abnormal brain cholesterol homeostasis was also inferred from studies in HD patients. In contrast, colorimetric and enzymatic methods indicate cholesterol accumulation in HD cells and tissues. Here we used several methods to investigate cholesterol levels in cultured cells in the presence or absence of mutant HTT protein. Results Colorimetric and enzymatic methods with low sensitivity gave variable results, whereas results from a sensitive analytical method, gas chromatography-mass spectrometry, were more reliable. Sample preparation, high cell density and cell clonality also influenced the detection of intracellular cholesterol. Conclusions Detection of cholesterol in HD samples by colorimetric and enzymatic assays should be supplemented by detection using more sensitive analytical methods. Care must be taken to prepare the sample appropriately. By evaluating lathosterol levels using isotopic dilution mass spectrometry, we confirmed reduced cholesterol biosynthesis in knock-in cells expressing the polyQ mutation in a constitutive or inducible manner. *Correspondence should be addressed to Elena Cattaneo: elena.cattaneo@unimi.it PMID:23145355
Mota, Maria Fernanda S; Souza, Marcella F; Bon, Elba P S; Rodrigues, Marcoaurelio A; Freitas, Suely Pereira
2018-05-24
The use of colorimetric methods for protein quantification in microalgae is hindered by their elevated amounts of membrane-embedded intracellular proteins. In this work, the protein content of three species of microalgae was determined by the Lowry method after the cells were dried, ball-milled, and treated with the detergent sodium dodecyl sulfate (SDS). Results demonstrated that the association of milling and SDS treatment resulted in a 3- to 7-fold increase in protein quantification. Milling promoted microalgal disaggregation and cell wall disruption enabling access of the SDS detergent to the microalgal intracellular membrane proteins and their efficient solubilization and quantification. © 2018 Phycological Society of America.
He, Liuying; Lu, Yuexiang; Wang, Feiyang; Gao, Xinxin; Chen, Ying; Liu, Yueying
2018-02-13
The authors describe a colorimetric method for the determination of Hg 2+ ions based on the inhibition of the activity of the enzyme urease. The pH value of solution increases when urease hydrolyzes urea, which can be visualized by adding a pH indicator such as Phenol Red (PhR). Mercaptoethanol as a typical thiol is added to the system to improve selectivity because it binds metal ions and then - unlike the Hg 2+ mercaptoethanol complex - does not inhibit urease. Hence, the color of the pH indicator PhR turns from yellow to pink as the solution becomes alkaline. The Hg 2+ mercaptoethanol complex, in contrast, strongly inhibits urease and the color of the solution remains yellow. The findings were used to design a photometric assay based on the measurement of the ratio of absorptions of PhR at 558 nm and 430 nm. It has a linear response over the 25 to 40 nM Hg 2+ concentration range and a 5 nM detection limit. This is well below the guideline values of Hg 2+ specified by the US Environmental Protection Agency and the World Health Organization for drinking water (10 nM and 30 nM, respectively). The method was employed to the determination of Hg 2+ in water samples spiked with 10 nM levels of Hg 2+ where color changes still can be observed visually. Graphical Abstract Schematic presentation of a colorimetric method for the ultrasensitive detection of Hg 2+ based on the inhibition of urease activity. Mercaptoethanol is used to improve the selectivity. Even at Hg 2+ concentrations as low as 5 nM, the color change still can be easily observed by bare eyes.
Choleva, Tatiana G; Gatselou, Vasiliki A; Tsogas, George Z; Giokas, Dimosthenis L
2017-12-05
The intrinsic peroxidase-like activity of rhodium nanoparticles (RhNPs) and their use as catalytic labels for sensitive colorimetric assays is presented. RhNPs catalyze the oxidation of the peroxidase substrate 3,3,5,5-tetramethylbenzidine (TMB) in the presence of H 2 O 2 to produce a blue reaction product with a maximum absorbance at 652 nm. Kinetic studies show catalysis to follow Michaelis-Menten kinetics and a "ping-pong" mechanism. The calculated kinetic parameters indicate high affinity of RhNPs for both the substrate TMB and H 2 O 2 . In fact, they are better than other peroxidase mimicking nanomaterials and even the natural enzyme horseradish peroxidase. On the other hand, RhNPs exhibit no reactivity towards saccharides, thiols, amino acids and ascorbic acid. Based on these findings, a sensitive and selective colorimetric method was worked out for the determination of H 2 O 2 in real samples with a linear response in the 1-100 μM concentration range. By employing glucose oxidase, the glucose assay has a linear range that covers the 5 to 125 μM glucose concentration range. The detection limits are <0.75 μM for both species. The methods were applied to the determination of H 2 O 2 in spiked pharmaceutical formulations, and of glucose in soft drinks and blood plasma. Figures of merit include (a) good accuracy (with errors of <6%), (b) high recoveries (96.5-103.7%), and (c) satisfactory reproducibility (<6.3%). Graphical abstract Rhodium nanoparticles catalyze the oxidation of 3,3,5,5-tetramethylbenzidine (TMB) in the presence of H 2 O 2 to produce a blue reaction product. The effect is exploited in photometric assays for hydrogen peroxide and glucose.
Colorimetric detection of copper in water using a Schiff base derivative
NASA Astrophysics Data System (ADS)
Peralta Domínguez, D.; Ramos-Ortiz, G.; Maldonado, J. L.; Rodriguez, M.; Meneses-Nava, M. A.; Barbosa-Garcia, O.; Santillan, R.; Farfán, N.
2013-09-01
Organic molecular sensors have the advantage of being used through an easy, fast, economical and reliable optical method for detecting toxic metal ions in our environment. In this work, we present a simple but highly specific organic ligand compound 5-Chloro-2-((E)-((E)-3-(4-(dimethylamino)phenyl)allylidene)amino)phenol (L1) that acts as a colorimetric sensor for ions in a mixture of acetonitrile/water (ratio 10:1, v:v). Binding interaction between L1 and various metal-ions has been established by ultraviolet-visible spectroscopic measurements that indicate favorable coordination of the ligand with selective metal ions, particularly, with copper. These results showed that the electronic transition band shape of L1 change after binding with copper in aqueous solution. L1 exhibited binding-induced color changes from yellow to pink one detected by the naked eye. This new sensor presented 2.5 × 10-6 M as limit detection, even under the presence of other metal ions.
Hassan, Wafaa El-Sayed
2008-08-01
Three rapid, simple, reproducible and sensitive extractive colorimetric methods (A--C) for assaying dothiepin hydrochloride (I) and risperidone (II) in bulk sample and in dosage forms were investigated. Methods A and B are based on the formation of an ion pair complexes with methyl orange (A) and orange G (B), whereas method C depends on ternary complex formation between cobalt thiocyanate and the studied drug I or II. The optimum reaction conditions were investigated and it was observed the calibration curves resulting from the measurements of absorbance concentration relations of the extracted complexes were linear over the concentration range 0.1--12 microg ml(-1) for method A, 0.5--11 mug ml(-1) for method B, and 3.2--80 microg ml(-1) for method C with a relative standard deviation (RSD) of 1.17 and 1.28 for drug I and II, respectively. The molar absorptivity, Sandell sensitivity, Ringbom optimum concentration ranges, and detection and quantification limits for all complexes were calculated and evaluated at maximum wavelengths of 423, 498, and 625 nm, using methods A, B, and C, respectively. The interference from excipients commonly present in dosage forms and common degradation products was studied. The proposed methods are highly specific for the determination of drugs I and II, in their dosage forms applying the standard additions technique without any interference from common excipients. The proposed methods have been compared statistically to the reference methods and found to be simple, accurate (t-test) and reproducible (F-value).
NASA Astrophysics Data System (ADS)
Li, Shaowei; Cao, Xiufang; Chen, Changshui; Ke, Shaoyong
2012-10-01
Based on the salicylic acid backbone, three highly sensitive and selective colorimetric chemosensors with an acylthiourea binding unit have been designed, synthesized and characterized. These chemosensors have been utilized for selective recognition of fluoride anions in dry DMSO solution by typical spectroscopic titration techniques. Furthermore, the obtained chemosensors AR1-3 have shown naked-eye sensitivity for detection of biologically important fluoride ion over other anions in solution.
Xuan, Shi-Hai; Zhou, Yu-Gui; Shao, Bo; Cui, Ya-Lin; Li, Jian; Yin, Hong-Bo; Song, Xiao-Ping; Cong, Hui; Jing, Feng-Xiang; Jin, Qing-Hui; Wang, Hui-Min; Zhou, Jie
2009-11-01
Macrolide drugs, such as clarithromycin (CAM), are a key component of many combination therapies used to eradicate Helicobacter pylori. However, resistance to CAM is increasing in H. pylori and is becoming a serious problem in H. pylori eradication therapy. CAM resistance in H. pylori is mostly due to point mutations (A2142G/C, A2143G) in the peptidyltransferase-encoding region of the 23S rRNA gene. In this study an enzymic colorimetry-based DNA chip was developed to analyse single-nucleotide polymorphisms of the 23S rRNA gene to determine the prevalence of mutations in CAM-related resistance in H. pylori-positive patients. The results of the colorimetric DNA chip were confirmed by direct DNA sequencing. In 63 samples, the incidence of the A2143G mutation was 17.46 % (11/63). The results of the colorimetric DNA chip were concordant with DNA sequencing in 96.83 % of results (61/63). The colorimetric DNA chip could detect wild-type and mutant signals at every site, even at a DNA concentration of 1.53 x 10(2) copies microl(-1). Thus, the colorimetric DNA chip is a reliable assay for rapid and accurate detection of mutations in the 23S rRNA gene of H. pylori that lead to CAM-related resistance, directly from gastric tissues.
A Colorimetric Sensor for Qualitative Discrimination and Quantitative Detection of Volatile Amines
Tang, Zhonglin; Yang, Jianhua; Yu, Junyun; Cui, Bo
2010-01-01
We have developed a novel colorimetric sensor based on a digital camera and white LED illumination. Colorimetric sensor arrays (CSAs) were made from a set of six chemically responsive dyes impregnated on an inert substrate plate by solution casting. Six common amine aqueous solutions, including dimethylamine, triethylamine, diisopropylamine, aniline, cyclohexylamine, and pyridine vaporized at 25 °C and six health-related trimethylamine (TMA) concentrations including 170 ppm, 51 ppm, 8 ppm, 2 ppm, 125 ppb and 50 ppb were analyzed by the sensor to test its ability for the qualitative discrimination and quantitative detection of volatile amines. We extracted the feature vectors of the CSA's response to the analytes from a fusional color space, which was obtained by conducting a joint search algorithm of sequential forward selection and sequential backward selection (SFS&SBS) based on the linear discriminant criteria (LDC) in a mixed color space composed of six common color spaces. The principle component analysis (PCA) followed by the hierarchical cluser analysis (HCA) were utilized to discriminate 12 analytes. Results showed that the colorimetric sensor grouped the six amine vapors and five TMA concentrations correctly, while TMA concentrations of 125 ppb and 50 ppb were indiscriminable from each other. The limitation of detection (LOD) of the sensor for TMA was found to be lower than 50 ppb. The CSAs were reusable for TMA concentrations below 8 ppm. PMID:22163560
Graphene quantum dot as a green and facile sensor for free chlorine in drinking water.
Dong, Yongqiang; Li, Geli; Zhou, Nana; Wang, Ruixue; Chi, Yuwu; Chen, Guonan
2012-10-02
Free chlorine was found to be able to destroy the passivated surface of the graphene quantum dots (GQDs) obtained by pyrolyzing citric acid, resulting in significant quenching of their fluorescence (FL) signal. After optimizing some experimental conditions (including response time, concentration of GQDs, and pH value of solution), a green and facile sensing system has been developed for the detection of free residual chlorine in water based on FL quenching of GQDs. The sensing system exhibits many advantages, such as short response time, excellent selectivity, wide linear response range, and high sensitivity. The linear response range of free chlorine (R(2) = 0.992) was from 0.05 to 10 μM. The detection limit (S/N = 3) was as low as 0.05 μM, which is much lower than that of the most widely used N-N-diethyl-p-phenylenediamine (DPD) colorimetric method. This sensing system was finally used to detect free residual chlorine in local tap water samples. The result agreed well with that by the DPD colorimetric method, suggesting the potential application of this new, green, sensitive, and facile sensing system in drinking water quality monitoring.
NASA Astrophysics Data System (ADS)
Di, Weihua; Zhang, Xiang; Qin, Weiping
2017-04-01
The rapid, sensitive and selective detection of glutathione (GSH) is of great importance in the biological systems. In this work, a template-free and one-step method was used to synthesize the single-layer MnO2 nanosheets via a redox reaction. The resulting product was characterized by XRD, TEM, FTIR, XPS and UV-vis absorption. The addition of GSH results in the change of solution color depth owing to the occurrence of a redox reaction between MnO2 and GSH, enabling colorimetric detection of GSH. At a pH of 3.6, the proposed sensor gives a linear calibration over a GSH concentration range of 10-100 μM, with a rapid response of less than 2 min and a low detection limit of 0.5 μM. The relative standard deviation for seven repeated determinations of GSH is lower than 5.6%. Furthermore, the chemical response of the synthesized MnO2 nanosheets toward GSH is selective. Owing to the advantages with good water solubility, rapid response, high sensitivity, good biocompatibility and operation simplicity, this two-dimensional MnO2-based sensing material might be potential for detecting GSH in biological applications.
GAMMA AND X-RAY DOSIMETER AND DOSIMETRIC METHOD
Taplin, G.V.; Douglas, C.H.; Sigoloff, S.C.
1958-08-19
An improvement in colorimetric gamma and x-ray dosimeter systems and a self-contained. hand carried dostmeter of the afore-mentioned type ts described. A novel point of the invention ltes in the addition of specific quantities of certain normalizing agents to the two phase chlorinated hydro-carbon-aqueous dyc colortmetric dosimeter to eliminate the after reaction and thereby extend the utility of such systein. The structure of the two phase colorimetric dosimeter tubes and the carrying case for the tubes of the portable dosimeter are unique features.
NASA Astrophysics Data System (ADS)
Khanmohammadi, Hamid; Rezaeian, Khatereh; Abdollahi, Alieh
2015-03-01
New N-monosubstituted diaminomaleonitrile-based azo-azomethine dyes have been synthesized in order to develop colorimetric sensors for detection of biologically important anions in aqueous media. Importantly, the reported sensor decorated with strong electron-withdrawing group can detect inorganic fluoride in water even at 0.037 ppm level, which is lower than WHO permissible level (below 1 ppm). Successfully, the prepared dyes were used for qualitative and quantitative detection of inorganic fluoride in toothpaste and mouthwash. The anion recognition mechanism was also investigated by detailed UV-Vis and 1H NMR experiments. The detailed 1H NMR experiments corroborated that anion recognition is based on the deprotonation phenomenon.
A high resolution Passive Flux Meter approach based on colorimetric responses
NASA Astrophysics Data System (ADS)
Chardi, K.; Dombrowski, K.; Cho, J.; Hatfield, K.; Newman, M.; Annable, M. D.
2016-12-01
Subsurface water and contaminant mass flux measurements are critical in determining risk, optimizing remediation strategies, and monitoring contaminant attenuation. The standard Passive Flux Meter, hereafter knows as a (PFM), is a well-developed device used for determining and monitoring rates of groundwater and contaminant mass flux in screened wells. The current PFM is a permeable device that contains granular activated carbon impregnated with alcohol tracers which is deployed in a flow field for a designated period of time. Once extracted, sampling requires laboratory analysis to quantify Darcy flux, which can be time consuming and have significant cost. To expedite test results, a modified PFM based on the image analysis of colorimetric responses, herein referred to as a colorimetric Passive Flux Meter (cPFM), was developed. Various dyes and sorbents were selected and evaluated to determine colorimetric response to water flow. Rhodamine, fluorescent yellow, fluorescent orange, and turmeric were the dye candidates while 100% wool and a 35% wool blend with 65% rayon were the sorbent candidates selected for use in the cPFM. Ultraviolet light image analysis was used to calculate average color intensity using ImageJ, a Java-based image processing program. These results were then used to quantify Darcy flux. Error ranges evaluated for Darcy flux using the cPFM are comparable to those with the standard, activated carbon based, PFM. The cPFM has the potential to accomplish the goal of obtaining high resolution Darcy flux data while eliminating high costs and analysis time. Implications of groundwater characteristics, such as PH and contaminant concentrations, on image analysis are to be tested through laboratory analysis followed by field testing of the cPFM.
Makris, Konstantinos C; Punamiya, Pravin; Sarkar, Dibyendu; Datta, Rupali
2008-02-01
A sensitive (method detection limit, 2.0 microg As L(-1)) colorimetric determination of trace As(v) and As(iii) concentrations in the presence of soluble phosphorus (P) concentrations in soil/water extracts is presented. The proposed method modifies the malachite green method (MG) originally developed for P in soil and water. Our method relies upon the finding that As(iii) and As(v) do not develop the green color during P analysis using the MG method. When an optimum concentration of ascorbic acid (AA) is added to a sample containing up to 15 times P > As (microM) concentrations, the final sample absorbance due to P will be equal to that of As(v) molecules. The soluble As concentration can then be quantified by the concentration difference between the mixed oxyanion (As + P) absorbance (proposed method) and the MG method absorbance that measures only P. Our method is miniaturized using a 96-well microplate UV-VIS reader that utilizes minute reagent and sample volumes (120 and 200 microL sample(-1), respectively), thus, minimizing waste and offering flexibility in the field. Our method was tested in a suite of As-contaminated soils that successfully measured both As and P in soil water extracts and total digests. Mean% As recoveries ranged between 84 and 117%, corroborating data obtained with high-resolution inductively-coupled plasma mass-spectrometry. The performance of the proposed colorimetric As method was unaffected by the presence of Cu, Zn, Pb, Ni, Fe, Al, Si, and Cr in both neutral and highly-acidic (ca. pH 2) soil extracts. Data from this study provide the proof of concept towards creating a field-deployable, portable As kit.
Detection of Bacteria Using Inkjet-Printed Enzymatic Test Strips
2015-01-01
Low-cost diagnostics for drinking water contamination have the potential to save millions of lives. We report a method that uses inkjet printing to copattern an enzyme–nanoparticle sensor and substrate on a paper-based test strip for rapid detection of bacteria. A colorimetric response is generated on the paper substrate that allows visual detection of contamination without the need for expensive instrumentation. These strips demonstrate a viable nanomanufacturing strategy for low-cost bacterial detection. PMID:25318086
Liquid-to-gel transition for visual and tactile detection of biological analytes.
Fedotova, Tatiana A; Kolpashchikov, Dmitry M
2017-11-23
So far all visual and instrument-free methods have been based on a color change. However, colorimetric assays cannot be used by blind or color-blind people. Here we introduce a liquid-to-gel transition as a general output platform. The signal output (a piece of gel) can be unambiguously distinguished from liquid both visually and by touch. This approach promises to contribute to the development of an accessible environment for visually impaired persons.
Martinez, Andres W; Phillips, Scott T; Carrilho, Emanuel; Thomas, Samuel W; Sindi, Hayat; Whitesides, George M
2008-05-15
This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.
NASA Astrophysics Data System (ADS)
Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping
2014-01-01
As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis. Electronic supplementary information (ESI) available: TEM images of individual MB@Au NPs, results of dynamic light scattering analysis and extinction spectrum obtained using colorimetry detection. See DOI: 10.1039/c3nr04942f
Wang, Yanying; Yang, Yan; Liu, Wei; Ding, Fang; Zhao, Qingbiao; Zou, Ping; Wang, Xianxiang; Rao, Hanbing
2018-05-04
A dual-read detection system is described for non-enzymatic and non-aggregation based analysis of uric acid (UA). Silver triangular nanoprisms (AgTNPs) were used as colorimetric probes, while the reduction in the fluorescence of nitrogen-doped carbon quantum dots (N-CQDs) served as the fluorometric readout. The absorption band of the AgTNPs overlaps the emission band of N-CQDs (with a peak at 440 nm). Therefore, fluorescence is reduced owing to an inner filter effect. The AgTNPs are etched if exposed to H 2 O 2 , and round nanodiscs are formed. In the presence of UA, etching of the AgTNPs is suppressed because the facets of the AgTNPs are coated with UA. The absorbance, best measured at 683 nm, increases with the concentration of the pre-added UA. The colorimetric assay works in the 0.1-45 μM UA concentration range, and the fluorometric assay between 1 and 42 μM of UA. The respective detection limits are 50 and 200 nM, respectively. The probe can be used for direct visualization of UA. The method was successfully applied to the determination of UA in urine samples. Graphical abstract The fluorescence of nitrogen-doped carbon quantum dots (N-CQDs) is quenched by AgTNPs (silver triangular nanoprisms). As the AgTNPs are etched by H 2 O 2 , fluorescence recovers in the system after H 2 O 2 is added, and also undergoes a color change. Uric acid (UA) protects the AgTNPs from etching because the facets of the AgTNPs are coated with UA. The fluorescence of N-CQDs decreases. Thus, a dual-read probe is developed for determination of UA.
Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.
2000-01-01
The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).
Sang, Fuming; Liu, Jia; Zhang, Xue; Pan, Jianxin
2018-04-25
A colorimetric method is described for the determination of Pt(II). It is based on the use of gold nanoparticles (AuNPs) which are known to aggregate in the presence of a cationic polymer such as poly(diallyldimethylammonium chloride) (PDDA). If, however, a mismatched aptamer (AA) electrostatically binds to PDDA, aggregation is prevented. Upon the addition of Pt(II), it will bind to the aptamer and induce the formation of a hairpin structure. Hence, interaction between aptamer and PDDA is suppressed and PDDA will induce the aggregation of the AuNPs. This is accompanied by a color change from red to blue. The effect can be observed with bare eyes and quantified by colorimetry via measurement of the ratio of absorbances at 610 nm and 520 nm. Response is linear in the 0.24-2 μM Pt(II) concentration range, and the detection limit is 58 nM. The assay is completed within 15 min and selective for Pt(II) even in the presence of other metal ions. It was successfully applied to the rapid determination of Pt(II) in spiked soil samples. Graphical abstract Schematic representation of the method for detection of Pt(II) based on the use of a cationic polymer and gold nanoparticles. In the presence of Pt(II), aptamer interacts with the Pt(II) and prevents the interaction between aptamer and cationic polymer. Hence, cationic polymer induce the aggregation of the AuNPs and lead to the color change from red to blue.
Zhang, Li; Wang, Zhong-Xia; Liang, Ru-Ping; Qiu, Jian-Ding
2013-07-16
Utilizing the principles of metal-ion-mediated base pairs (C-Ag-C and T-Hg-T), the pH-sensitive conformational transition of C-rich DNA strand, and the ligand-exchange process triggered by DL-dithiothreitol (DTT), a system of colorimetric logic gates (YES, AND, INHIBIT, and XOR) can be rationally constructed based on the aggregation of the DNA-modified Au NPs. The proposed logic operation system is simple, which consists of only T-/C-rich DNA-modified Au NPs, and it is unnecessary to exquisitely design and alter the DNA sequence for different multiple molecular logic operations. The nonnatural base pairing combined with unique optical properties of Au NPs promises great potential in multiplexed ion sensing, molecular-scale computers, and other computational logic devices.
Cho, Eun Na Rae; Li, Yinan; Kim, Hee Jin; Hyun, Myung Ho
2011-04-01
A new colorimetric chiral sensor material consisting of three different functional sites such as chromophore (2,4-dinitrophenylazophenol dye), binding site (crown ether), and chiral barrier (3,3'-diphenyl-1,1'-binaphthyl group) was prepared and applied to the recognition of the two enantiomers of primary amino alcohols and amines. Among five primary amino alcohols and two primary amines tested, the two enantiomers of phenylalaninol show the highest difference in the absorption maximum wavelength (Δλ(max)=43.5 nm) and in the association constants (K(S)/K(R)=2.51) upon complexation with the colorimetric chiral sensor material and, consequently, the two enantiomers of phenylalaninol were clearly distinguished from each other by the color difference. Copyright © 2010 Wiley-Liss, Inc.
Zhu, Nuanfei; Zou, Yanmin; Huang, Menglu; Dong, Shuaibing; Wu, Xiangyang; Liang, Guoxi; Han, Zhixiang; Zhang, Zhen
2018-08-15
A sensitive and artful colorimetric immunosensor based on horseradish peroxidase (HRP) was designed by labelling metal-organic frameworks (Cu-MOFs) on the second antibody (Cu-MOFs@Ab 2 ) as signal amplification for the detection of trace dibutyl phthalate (DBP). In this system, when Cu-MOFs@Ab 2 was captured by antigen- primary antibody (Ab 1 ) complex, tremendous Cu(II) will be released from Cu-MOFs in the presence of nitric acid (HNO 3 ), and Cu(II) will be further reduced to Cu(I) after the addition of sodium ascorbate (SA), consequently, inhibiting the HRP to catalyse the colorless 3,3',5,5'-tetramethylbenzidine (TMB) into blue oxidized TMB (ox TMB). Under the optimized conditions, the limit of detection (LOD) was 1 μg L -1 , which was almost 60 times lower than that using a conventional ELISA with the same antibody. In addition, our method showed good accuracy and reproducibility (recoveries of 87.73-103.4%; CV values of 1.46-5.95%) through a spike-recovery analysis. The proposed immunosensor indicated great potential for trace DBP determination from environmental and food samples. Copyright © 2018. Published by Elsevier B.V.
A colorimetric sensor for the selective detection of fluoride ions.
Wan, Chin-Feng; Chir, Jiun-Ly; Wu, An-Tai
2017-05-01
A colorimetric receptor L was prepared. Receptor L can selectively sense F - based on distinct color changes among a series of ions. It can selectively sense F - through an intramolecular hydrogen bond interaction. A Job plot indicated a 1:1 complexation stoichiometry between receptor L and F - . The association constant for L-F - in CH 3 CN was determined as 9.70 × 10 4 M -1 using a Stern-Volmer plot. Copyright © 2016 John Wiley & Sons, Ltd.
Glycation of antibodies: Modification, methods and potential effects on biological functions.
Wei, Bingchuan; Berning, Kelsey; Quan, Cynthia; Zhang, Yonghua Taylor
Glycation is an important protein modification that could potentially affect bioactivity and molecular stability, and glycation of therapeutic proteins such as monoclonal antibodies should be well characterized. Glycated protein could undergo further degradation into advance glycation end (AGE) products. Here, we review the root cause of glycation during the manufacturing, storage and in vivo circulation of therapeutic antibodies, and the current analytical methods used to detect and characterize glycation and AGEs, including boronate affinity chromatography, charge-based methods, liquid chromatography-mass spectrometry and colorimetric assay. The biological effects of therapeutic protein glycation and AGEs, which ranged from no affect to loss of activity, are also discussed.
Huang, Yanyan; Ran, Xiang; Lin, Youhui; Ren, Jinsong; Qu, Xiaogang
2015-04-22
Based on enzymatic reactions-triggered changes of pH values and biocomputing, a novel and multistage interconnection biological network with multiple easy-detectable signal outputs has been developed. Compared with traditional chemical computing, the enzyme-based biological system could overcome the interference between reactions or the incompatibility of individual computing gates and offer a unique opportunity to assemble multicomponent/multifunctional logic circuitries. Our system included four enzyme inputs: β-galactosidase (β-gal), glucose oxidase (GOx), esterase (Est) and urease (Ur). With the assistance of two signal transducers (gold nanoparticles and acid-base indicators) or pH meter, the outputs of the biological network could be conveniently read by the naked eyes. In contrast to current methods, the approach present here could realize cost-effective, label-free and colorimetric logic operations without complicated instrument. By designing a series of Boolean logic operations, we could logically make judgment of the compositions of the samples on the basis of visual output signals. Our work offered a promising paradigm for future biological computing technology and might be highly useful in future intelligent diagnostics, prodrug activation, smart drug delivery, process control, and electronic applications. Copyright © 2015 Elsevier B.V. All rights reserved.
Development of a high-throughput colorimetric Zika virus infection assay.
Müller, Janis A; Harms, Mirja; Schubert, Axel; Mayer, Benjamin; Jansen, Stephanie; Herbeuval, Jean-Philippe; Michel, Detlef; Mertens, Thomas; Vapalahti, Olli; Schmidt-Chanasit, Jonas; Münch, Jan
2017-04-01
Zika virus (ZIKV) is an emerging pathogen that causes congenital infections which may result in birth defects, such as microcephaly. Currently, no approved treatment or vaccination is available. ZIKV can be readily detected in cell culture where virally infected cells are normally stained by specific antibodies. As ZIKV regularly causes a cytopathic effect, we were wondering whether this viral property can be used to quantitatively determine viral infectivity. We here describe the use of an 3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2H-tetrazolium bromide-(MTT)-based cell viability assay that allows to determine ZIKV-induced cell death. We show that this colorimetric assay quantifies ZIKV infection over a broad range of viral dilutions in both monkey and human cells. It allows to determine inhibitory activities of antivirals that block ZIKV or to define the neutralizing antibody titers of ZIKV antisera. This MTT-based ZIKV detection assay can be evaluated by naked eye or computational tools, has a broad linear range, does not require large equipment or costly reagents, and thus represents a promising alternative to antibody-based assays, in particular in resource-poor settings. We propose to use this simple, fast, and cheap method for quantification of ZIKV neutralizing antibodies and testing of antiviral compounds.
Evaluating an alternative method for rapid urinary creatinine determination
Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...
A novel coumarin Schiff-base as a Ni(II) ion colorimetric sensor
NASA Astrophysics Data System (ADS)
Wang, Lingyun; Ye, Decheng; Cao, Derong
2012-05-01
A novel coumarin Schiff base compound (L) prepared from 7-diethylaminocoumarin-3-aldehyde and 3-amino-7-hydroxycoumarin was synthesized and evaluated as a chemoselective Ni2+ sensor. Addition of Ni2+ to CH3CN solution of L resulted in a rapid color change from yellow to red together with a large red shift from 465 to 516 nm. Moreover, other common alkali-, alkaline earth-, transition- and rare earth metal ions induced no or minimal spectral changes. Experimental results indicated that L could be used as a potential Ni2+ colorimetric and naked-eye chemosensor in CH3CN solution.
Interfacial polymerization for colorimetric labeling of protein expression in cells.
Lilly, Jacob L; Sheldon, Phillip R; Hoversten, Liv J; Romero, Gabriela; Balasubramaniam, Vivek; Berron, Brad J
2014-01-01
Determining the location of rare proteins in cells typically requires the use of on-sample amplification. Antibody based recognition and enzymatic amplification is used to produce large amounts of visible label at the site of protein expression, but these techniques suffer from the presence of nonspecific reactivity in the biological sample and from poor spatial control over the label. Polymerization based amplification is a recently developed alternative means of creating an on-sample amplification for fluorescence applications, while not suffering from endogenous labels or loss of signal localization. This manuscript builds upon polymerization based amplification by developing a stable, archivable, and colorimetric mode of amplification termed Polymer Dye Labeling. The basic concept involves an interfacial polymer grown at the site of protein expression and subsequent staining of this polymer with an appropriate dye. The dyes Evans Blue and eosin were initially investigated for colorimetric response in a microarray setting, where both specifically stained polymer films on glass. The process was translated to the staining of protein expression in human dermal fibroblast cells, and Polymer Dye Labeling was specific to regions consistent with desired protein expression. The labeling is stable for over 200 days in ambient conditions and is also compatible with modern mounting medium.
NASA Astrophysics Data System (ADS)
Lee, Ai Cheng; Ye, Jian-Shan; Ngin Tan, Swee; Poenar, Daniel P.; Sheu, Fwu-Shan; Kiat Heng, Chew; Meng Lim, Tit
2007-11-01
A novel carbon nanotube (CNT) derived label capable of dramatic signal amplification of nucleic acid detection and direct visual detection of target hybridization has been developed. Highly sensitive colorimetric detection of human acute lymphocytic leukemia (ALL) related oncogene sequences amplified by the novel CNT-based label was demonstrated. Atomic force microscope (AFM) images confirmed that a monolayer of horseradish peroxidase and detection probe molecules was immobilized along the carboxylated CNT carrier. The resulting CNT labels significantly enhanced the nucleic acid assay sensitivity by at least 1000 times compared to that of conventional labels used in enzyme-linked oligosorbent assay (ELOSA). An excellent detection limit of 1 × 10-12 M (60 × 10-18 mol in 60 µl) and a four-order wide dynamic range of target concentration were achieved. Hybridizations using these labels were coupled to a concentration-dependent formation of visible dark aggregates. Targets can thus be detected simply with visual inspection, eliminating the need for expensive and sophisticated detection systems. The approach holds promise for ultrasensitive and low cost visual inspection and colorimetric nucleic acid detection in point-of-care and early disease diagnostic application.
NASA Astrophysics Data System (ADS)
Mølgaard, Lasse L.; Buus, Ole T.; Larsen, Jan; Babamoradi, Hamid; Thygesen, Ida L.; Laustsen, Milan; Munk, Jens Kristian; Dossi, Eleftheria; O'Keeffe, Caroline; Lässig, Lina; Tatlow, Sol; Sandström, Lars; Jakobsen, Mogens H.
2017-05-01
We present a data-driven machine learning approach to detect drug- and explosives-precursors using colorimetric sensor technology for air-sampling. The sensing technology has been developed in the context of the CRIM-TRACK project. At present a fully- integrated portable prototype for air sampling with disposable sensing chips and automated data acquisition has been developed. The prototype allows for fast, user-friendly sampling, which has made it possible to produce large datasets of colorimetric data for different target analytes in laboratory and simulated real-world application scenarios. To make use of the highly multi-variate data produced from the colorimetric chip a number of machine learning techniques are employed to provide reliable classification of target analytes from confounders found in the air streams. We demonstrate that a data-driven machine learning method using dimensionality reduction in combination with a probabilistic classifier makes it possible to produce informative features and a high detection rate of analytes. Furthermore, the probabilistic machine learning approach provides a means of automatically identifying unreliable measurements that could produce false predictions. The robustness of the colorimetric sensor has been evaluated in a series of experiments focusing on the amphetamine pre-cursor phenylacetone as well as the improvised explosives pre-cursor hydrogen peroxide. The analysis demonstrates that the system is able to detect analytes in clean air and mixed with substances that occur naturally in real-world sampling scenarios. The technology under development in CRIM-TRACK has the potential as an effective tool to control trafficking of illegal drugs, explosive detection, or in other law enforcement applications.
Cell viability monitoring using Fano resonance in gold nanoslit array
NASA Astrophysics Data System (ADS)
Wu, Shu-Han; Hsieh, Shu-Yi; Lee, Kuang-Li; Weng, Ruei-Hung; Chiou, Arthur; Wei, Pei-Kuen
2013-09-01
Cell viability is a crucial issue in biological research. We present label-free monitoring of adhesion cells viability by gold nanoslits-based Fano resonance biosensors. Plastic multiple wells with gold nanoslits substrate were made using a thermal nanoimprint method. Adhesion cells in the wells were treated with doxorubicin for inducing cell death and compared with conventional colorimetric assay. The nanoslits method shows better respones of viability tests under low concentration and short interaction time due to its high surface sensitivies. The vinculin labelling indicates that the measured signals are in good agreement with the adhesion abilities of cells.
Optimum color filters for CCD digital cameras
NASA Astrophysics Data System (ADS)
Engelhardt, Kai; Kunz, Rino E.; Seitz, Peter; Brunner, Harald; Knop, Karl
1993-12-01
As part of the ESPRIT II project No. 2103 (MASCOT) a high performance prototype color CCD still video camera was developed. Intended for professional usage such as in the graphic arts, the camera provides a maximum resolution of 3k X 3k full color pixels. A high colorimetric performance was achieved through specially designed dielectric filters and optimized matrixing. The color transformation was obtained by computer simulation of the camera system and non-linear optimization which minimized the perceivable color errors as measured in the 1976 CIELUV uniform color space for a set of about 200 carefully selected test colors. The color filters were designed to allow perfect colorimetric reproduction in principle and at the same time with imperceptible color noise and with special attention to fabrication tolerances. The camera system includes a special real-time digital color processor which carries out the color transformation. The transformation can be selected from a set of sixteen matrices optimized for different illuminants and output devices. Because the actual filter design was based on slightly incorrect data the prototype camera showed a mean colorimetric error of 2.7 j.n.d. (CIELUV) in experiments. Using correct input data in the redesign of the filters, a mean colorimetric error of only 1 j.n.d. (CIELUV) seems to be feasible, implying that it is possible with such an optimized color camera to achieve such a high colorimetric performance that the reproduced colors in an image cannot be distinguished from the original colors in a scene, even in direct comparison.
Discrimination of complex mixtures by a colorimetric sensor array: coffee aromas.
Suslick, Benjamin A; Feng, Liang; Suslick, Kenneth S
2010-03-01
The analysis of complex mixtures presents a difficult challenge even for modern analytical techniques, and the ability to discriminate among closely similar such mixtures often remains problematic. Coffee provides a readily available archetype of such highly multicomponent systems. The use of a low-cost, sensitive colorimetric sensor array for the detection and identification of coffee aromas is reported. The color changes of the sensor array were used as a digital representation of the array response and analyzed with standard statistical methods, including principal component analysis (PCA) and hierarchical clustering analysis (HCA). PCA revealed that the sensor array has exceptionally high dimensionality with 18 dimensions required to define 90% of the total variance. In quintuplicate runs of 10 commercial coffees and controls, no confusions or errors in classification by HCA were observed in 55 trials. In addition, the effects of temperature and time in the roasting of green coffee beans were readily observed and distinguishable with a resolution better than 10 degrees C and 5 min, respectively. Colorimetric sensor arrays demonstrate excellent potential for complex systems analysis in real-world applications and provide a novel method for discrimination among closely similar complex mixtures.
Discrimination of Complex Mixtures by a Colorimetric Sensor Array: Coffee Aromas
Suslick, Benjamin A.; Feng, Liang; Suslick, Kenneth S.
2010-01-01
The analysis of complex mixtures presents a difficult challenge even for modern analytical techniques, and the ability to discriminate among closely similar such mixtures often remains problematic. Coffee provides a readily available archetype of such highly multicomponent systems. The use of a low-cost, sensitive colorimetric sensor array for the detection and identification of coffee aromas is reported. The color changes of the sensor array were used as a digital representation of the array response and analyzed with standard statistical methods, including principal component analysis (PCA) and hierarchical clustering analysis (HCA). PCA revealed that the sensor array has exceptionally high dimensionality with 18 dimensions required to define 90% of the total variance. In quintuplicate runs of 10 commercial coffees and controls, no confusions or errors in classification by HCA were observed in 55 trials. In addition, the effects of temperature and time in the roasting of green coffee beans were readily observed and distinguishable with a resolution better than 10 °C and 5 min, respectively. Colorimetric sensor arrays demonstrate excellent potential for complex systems analysis in real-world applications and provide a novel method for discrimination among closely similar complex mixtures. PMID:20143838
Domínguez-Henao, Laura; Turolla, Andrea; Monticelli, Damiano; Antonelli, Manuela
2018-06-01
The recent growing interest in peracetic acid (PAA) as disinfectant for wastewater treatment demands reliable and readily-available methods for its measurement. In detail, the monitoring of PAA in wastewater treatment plants requires a simple, accurate, rapid and inexpensive measurement procedure. In the present work, a method for analyzing low concentrations of PAA, adapted from the US EPA colorimetric method for total chlorine, is assessed. This method employs N,N-diethyl-p-phenylelnediamine (DPD) in the presence of an excess of iodide in a phosphate buffer system. Pink colored species are produced proportionally to the concentration of PAA in the sample. Considering that PAA is available commercially as an equilibrium solution of PAA and hydrogen peroxide (H 2 O 2 ), a measurement method for H 2 O 2 is also investigated. This method, as the one for the determination of PAA, is also based on the oxidation of iodide to iodine, with the difference that ammonium molybdate Mo(VI) is added to catalyze the oxidation reaction between H 2 O 2 and iodide, quantifying the total peroxides (PAA+ H 2 O 2 ). The two methods are suitable for concentration ranges from about 0.1-1.65 mg L -1 and from about 0.3-3.3 mg L -1 , respectively for PAA and H 2 O 2 . Moreover, the work elucidates some relevant aspects related to the operational conditions, kinetics and the possible interference of H 2 O 2 on PAA measurement. Copyright © 2018 Elsevier B.V. All rights reserved.
Design of a colorimetric sensing platform using reflection mode plasmonic colour filters
NASA Astrophysics Data System (ADS)
Mudachathi, Renilkumar; Tanaka, Takuo
2017-08-01
Plasmonic nano structures fabricated using inexpensive and abundant aluminum metal shows intense narrow reflection peaks with strong response to the external stimuli, provides a simple yet powerful detection mechanism that is well suited for the development of low cost and low power sensors, such as colorimetric sensors, which transduces external stimuli or environmental changes in to visible colour changes. Such low cost and disposable sensors have huge demands in the point-of-care and home health care diagnostic applications. We present the design of a colorimetric sensing platform based on reflection mode plasmonic colour filters on both silicon and glass substrate, which demonstrate a sharp colour change for varying ambient refractive index. The sensor is essentially a plasmonic metamaterial in which the aluminum square plate hovering on a PMMA nano pillar in the background of a perforated aluminum reflector forms the unit cell which is arranged periodically in a 2D square lattice. The meta-surface has two distinct absorption peaks in the visible region leaving a strong reflection band, which strongly responds to the ambient refractive index change, provides a means for the realization of low cost colorimetric sensing platform.
Colorimetric sensing of anions in water using ratiometric indicator-displacement assay.
Feng, Liang; Li, Hui; Li, Xiao; Chen, Liang; Shen, Zheng; Guan, Yafeng
2012-09-19
The analysis of anions in water presents a difficult challenge due to their low charge-to-radius ratio, and the ability to discriminate among similar anions often remains problematic. The use of a 3×6 ratiometric indicator-displacement assay (RIDA) array for the colorimetric detection and identification of ten anions in water is reported. The sensor array consists of different combinations of colorimetric indicators and metal cations. The colorimetric indicators chelate with metal cations, forming the color changes. Upon the addition of anions, anions compete with the indicator ligands according to solubility product constants (K(sp)). The indicator-metal chelate compound changes color back dramatically when the competition of anions wins. The color changes of the RIDA array were used as a digital representation of the array response and analyzed with standard statistical methods, including principal component analysis and hierarchical clustering analysis. No confusion or errors in classification by hierarchical clustering analysis were observed in 44 trials. The limit of detection was calculated approximately, and most limits of detections of anions are well below μM level using our RIDA array. The pH effect, temperature influence, interfering anions were also investigated, and the RIDA array shows the feasibility of real sample testing. Copyright © 2012 Elsevier B.V. All rights reserved.
Detection of heavy metal by paper-based microfluidics.
Lin, Yang; Gritsenko, Dmitry; Feng, Shaolong; Teh, Yi Chen; Lu, Xiaonan; Xu, Jie
2016-09-15
Heavy metal pollution has shown great threat to the environment and public health worldwide. Current methods for the detection of heavy metals require expensive instrumentation and laborious operation, which can only be accomplished in centralized laboratories. Various microfluidic paper-based analytical devices have been developed recently as simple, cheap and disposable alternatives to conventional ones for on-site detection of heavy metals. In this review, we first summarize current development of paper-based analytical devices and discuss the selection of paper substrates, methods of device fabrication, and relevant theories in these devices. We then compare and categorize recent reports on detection of heavy metals using paper-based microfluidic devices on the basis of various detection mechanisms, such as colorimetric, fluorescent, and electrochemical methods. To finalize, the future development and trend in this field are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Meletiadis, Joseph; Mouton, Johan W.; Meis, Jacques F. G. M.; Verweij, Paul E.
2003-01-01
The in vitro interaction between terbinafine and the azoles voriconazole, miconazole, and itraconazole against five clinical Scedosporium prolificans isolates after 48 and 72 h of incubation was tested by a microdilution checkerboard (eight-by-twelve) technique. The antifungal effects of the drugs alone and in combination on the fungal biomass as well as on the metabolic activity of fungi were measured using a spectrophotometric method and two colorimetric methods, based on the lowest drug concentrations showed 75 and 50% growth inhibition (MIC-1 and MIC-2, respectively). The nature and the intensity of the interactions were assessed using a nonparametric approach (fractional inhibitory concentration [FIC] index model) and a fully parametric response surface approach (Greco model) of the Loewe additivity (LA) no-interaction theory as well as a nonparametric (Prichard model) and a semiparametric response surface approaches of the Bliss independence (BI) no-interaction theory. Statistically significant synergy was found between each of the three azoles and terbinafine in all cases, although with different intensities. A 27- to 64-fold and 16- to 90-fold reduction of the geometric mean of the azole and terbinafine MICs, respectively, was observed when they were combined, resulting in FIC indices of <1 to 0.02. Using the MIC-1 higher levels of synergy were obtained, , which were more consistent between the two incubation periods than using the MIC-2. The strongest synergy among the azoles was found with miconazole using the BI-based models and with voriconazole using the LA-based models. The synergistic effects both on fungal growth and metabolic activity were more potent after 72 h of incubation. Fully parametric approaches in combination with the modified colorimetric method might prove useful for testing the in vitro interaction of antifungal drugs against filamentous fungi. PMID:12499177
Niu, Yiming; Wang, Jiayi; Zhang, Chi; Chen, Yiqiang
2017-04-15
The objective of this study was to develop a micro-plate based colorimetric assay for rapid and high-throughput detection of copper in animal feed. Copper ion in animal feed was extracted by trichloroacetic acid solution and reduced to cuprous ion by hydroxylamine. The cuprous ion can chelate with 2,2'-bicinchoninic acid to form a Cu-BCA complex which was detected with high sensitivity by micro-plate reader at 354nm. The whole assay procedure can be completed within 20min. To eliminate matrix interference, a statistical partitioning correction approach was proposed, which makes the detection of copper in complex samples possible. The limit of detection was 0.035μg/mL and the detection range was 0.1-10μg/mL of copper in buffer solution. Actual sample analysis indicated that this colorimetric assay produced results consistent with atomic absorption spectrometry analysis. These results demonstrated that the developed assay can be used for rapid determination of copper in animal feed. Copyright © 2016 Elsevier Ltd. All rights reserved.
This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.
Naked-eye fingerprinting of single nucleotide polymorphisms on psoriasis patients
NASA Astrophysics Data System (ADS)
Valentini, Paola; Marsella, Alessandra; Tarantino, Paolo; Mauro, Salvatore; Baglietto, Silvia; Congedo, Maurizio; Paolo Pompa, Pier
2016-05-01
We report a low-cost test, based on gold nanoparticles, for the colorimetric (naked-eye) fingerprinting of a panel of single nucleotide polymorphisms (SNPs), relevant for the personalized therapy of psoriasis. Such pharmacogenomic tests are not routinely performed on psoriasis patients, due to the high cost of standard technologies. We demonstrated high sensitivity and specificity of our colorimetric test by validating it on a cohort of 30 patients, through a double-blind comparison with two state-of-the-art instrumental techniques, namely reverse dot blotting and sequencing, finding 100% agreement. This test offers high parallelization capabilities and can be easily generalized to other SNPs of clinical relevance, finding broad utility in diagnostics and pharmacogenomics.We report a low-cost test, based on gold nanoparticles, for the colorimetric (naked-eye) fingerprinting of a panel of single nucleotide polymorphisms (SNPs), relevant for the personalized therapy of psoriasis. Such pharmacogenomic tests are not routinely performed on psoriasis patients, due to the high cost of standard technologies. We demonstrated high sensitivity and specificity of our colorimetric test by validating it on a cohort of 30 patients, through a double-blind comparison with two state-of-the-art instrumental techniques, namely reverse dot blotting and sequencing, finding 100% agreement. This test offers high parallelization capabilities and can be easily generalized to other SNPs of clinical relevance, finding broad utility in diagnostics and pharmacogenomics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02200f
Wu, Dong; Xu, Huo; Shi, Haimei; Li, Weihong; Sun, Mengze; Wu, Zai-Sheng
2017-03-08
K-Ras mutations at codon 12 play an important role in an early step of carcinogenesis. Here, a label-free colorimetric isothermal cascade amplification for ultrasensitive and specific detection of K-Ras point mutation is developed based on a double-hairpin molecular beacon (DHMB). The biosensor consists of DHMB probe and a primer-incorporated polymerization template (PPT) designed partly complementary to DHMB. In the presence of polymerase, target DNA is designed to trigger strand displacement amplification (SDA) via promote the hybridization of PPT with DHMB and subsequently initiates cascade amplification process with the help of the nicking endonuclease. During the hybridization and enzymatic reaction, G-quadruplex/hemin DNAzymes are generated, catalyzing the oxidation of ABTS 2- by H 2 O 2 in the presence of hemin. Utilizing the proposed facile colorimetric scheme, the target DNA can be quantified down to 4 pM with the dynamic response range of 5 orders of magnitude, indicating the substantially improved detection capability. Even more strikingly, point mutation in K-ras gene can be readily observed by the naked eye without the need for the labeling or expensive equipment. Given the high-performance for K-Ras analysis, the enhanced signal transduction capability associated with double-hairpin structure of DHMB provides a novel rout to screen biomarkers, and the descripted colorimetric biosensor seems to hold great promise for diagnostic applications of genetic diseases. Copyright © 2016 Elsevier B.V. All rights reserved.
Singh, Jaswant; Parkash, Jyoti; Kaur, Varinder; Singh, Raghubir
2017-10-05
A new method is reported for the quantification of some metallic components of healthcare products utilizing a Schiff base chelator derived from 2-hydroxyacetophenone and ethanolamine. The Schiff base chelator recognizes some metallic species such as iron, copper and zinc (important components of some healthcare products), and cadmium (common contaminant in healthcare products) giving colorimetric/fluorimetric response. It coordinates with Fe 2+ /Fe 3+ and Cu 2+ ions via ONO donor set and switches the colour to bright red, green and orange, respectively. Similarly, it switches 'ON' a fluorometric response when coordinates with Zn 2+ and Cd 2+ ions. In the present approach, detailed studies on the colorimetric and fluorimetric response of ONO Schiff base is investigated in detail. The Job plot for the complexation of ONO switch with various metal ions suggested formation of 1:1 (metal-chelator) complex with Fe 2+ , Fe 3+ , and Cu 2+ while 1:2 (metal-chelator) for Zn 2+ and Cd 2+ ions. The limit of detection, limit of quantification are 6.73, 18.0, 25.0, 0.65, 1.10μM and 27.0, 72.0, 100.0, 2.60 and 4.40μM for Fe 2+ , Fe 3+ , Cu 2+ , Zn 2+ and Cd 2+ ions, respectively. Under the optimized conditions, chelator was used for the quantification of important metals present in healthcare products via direct dissolution and furnace treatment during sample preparation. The results were found precise and accurate for both sample preparation techniques using the developed method. Copyright © 2017 Elsevier B.V. All rights reserved.
Colorimetric evaluation of iPhone apps for colour vision tests based on the Ishihara test.
Dain, Stephen J; AlMerdef, Ali
2016-05-01
Given the versatility of smart phone displays, it was inevitable that applications (apps) providing colour vision testing would appear as an option. In this study, the colorimetric characteristics of five available iPhone apps for colour vision testing are assessed as a prequel to possible clinical evaluation. The colours of the displays produced by the apps are assessed with reference to the colours of a printed Ishihara test. The visual task is assessed on the basis of the colour differences and the alignment to the dichromatic confusion lines. The apps vary in quality and while some are colorimetrically acceptable, there are also some problems with their construction in making them a clinically useful app rather than curiosity driven self-testing. There is no reason why, in principle, a suitable test cannot be designed for smart phones. © 2016 Optometry Australia.
Battery operated preconcentration-assisted lateral flow assay.
Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon
2017-07-11
Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.
Uzer, A; Erçağ, E; Apak, R
2008-03-31
On-site colorimetric methods are a valuable, cost-effective tool to assess the nature and extent of contamination in remediated sites and to enable on-site screening for police criminology laboratories. The existing colorimetric method for cyclotrimethylenetrinitramine (RDX) based on a Griess reaction suffers from the non-quantitative reduction to nitrite and from the unstable character of HNO2 in acidic medium. Thus we propose a novel spectrophotometric RDX assay in explosive mixtures and residues, based on (Zn+HCl) reduction of RDX in a microwave oven, followed by neutralization of the reduction products to ammonia and low molecular-weight amines, and Berthelot reaction of these amine-compounds with phenol and hypochlorite in alkaline medium to give an intensely blue indophenol dye absorbing at 631nm. The molar absorptivity and limit of detection (LOD) for RDX were (1.08+/-0.04)x10(4) L mol(-1) cm(-1) and 0.18 mg L(-1), respectively. Application of the method to synthetic mixture solutions of RDX and trinitrotoluene (TNT) at varying proportions showed that there was minimal interference from TNT (which could be compensated for by dicyclohexylamine colorimetry), since the Berthelot reaction was essentially non-responsive to m-substituted anilines derived from TNT upon (Zn+HCl) reduction. The proposed method was successfully applied to military-purpose explosive mixtures of (RDX+inert matter) such as Comp A5, Comp C4, and Hexal P30, and to (RDX+TNT) mixtures such as Comp B. The molar absorptivity of RDX was much higher than that of either ammonium or nitrate; RDX could be effectively separated from ammonium and nitrate in soil mixtures, based on solubility differences. The Berthelot method for RDX was statistically validated using Comp B mixtures against standard HPLC equipped with a Hypersil C-18 column with (40% MeOH-60% H2O) mobile phase, and against gas chromatography-thermal energy analysis (GC-TEA) system.
Passive Leak Detection Using Commercial Hydrogen Colorimetric Indicator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartmann, Kevin; Buttner, William; Burgess, Robert
Element One, Inc. (www.elem.com), a small business with in Boulder, CO, has been developing hydrogen detection technology based upon a highly selective colorimetric indicator. In its native state, the indicator pigment is a pale gray color, but becomes black upon exposure to hydrogen. The colorimetric change can be readily observed by the naked eye without the need for supplemental electronics or other hardware. Recently, the colorimetric indicator was integrated into a pliable, self-adhesive tape that can readily wrap around pneumatic fittings to serve as a hydrogen leak detector. A prototype version of the Element One indicator tape was tested withinmore » an NREL hydrogen system and successfully identified the unexpected presence of a small leak; a summary document for this case study is presented in Appendix 1. The tape was subsequently configured into 10-foot rolls as a product prototype that has just recently been commercialized and marketed under the tradename DetecTape(R). Figure 1 shows the commercial version of DetecTape along with an indicator sample in its native state and one that had been exposed to hydrogen. DetecTape is a self-adhesive silicone-based tape impregnated with a proprietary hydrogen-sensitive indicator based on transition metal oxides. A length of the tape can be cut from the roll and stretched by a factor of two or three times around a fitting. Due to the self-adhesive property of the tape, this provides a tight seal around the fitting. The seal is not hermetic, and is not intended to prevent the release of a leaking gas. However, a portion of the hydrogen leaking from a wrapped fitting will pass through the tape and react with the active indicator impregnated within the tape, thereby inducing blackening.« less
Senarathna, S.M.D.K. Ganga; Ranganathan, Shalini S.; Buckley, Nick; Soysa, S.S.S.B.D. Preethi; Fernandopulle, B. M. Rohini
2012-01-01
Objectives: Acute paracetamol poisoning is an emerging problem in Sri Lanka. Management guidelines recommend ingested dose and serum paracetamol concentrations to assess the risk. Our aim was to determine the usefulness of the patient's history of an ingested dose of >150 mg/kg and paracetamol concentration obtained by a simple colorimetric method to assess risk in patients with acute paracetamol poisoning. Materials and Methods: Serum paracetamol concentrations were determined in 100 patients with a history of paracetamol overdose using High Performance Liquid Chromatography (HPLC); (reference method). The results were compared to those obtained with a colorimetric method. The utility of risk assessment by reported dose ingested and colorimetric analysis were compared. Results: The area under the receiver operating characteristic curve for the history of ingested dose was 0.578 and there was no dose cut-off providing useful risk categorization. Both analytical methods had less than 5% intra- and inter-batch variation and were accurate on spiked samples. The time from blood collection to result was six times faster and ten times cheaper for colorimetry (30 minutes, US$2) than for HPLC (180 minutes, US$20). The correlation coefficient between the paracetamol levels by the two methods was 0.85. The agreement on clinical risk categorization on the standard nomogram was also good (Kappa = 0.62, sensitivity 81%, specificity 89%). Conclusions: History of dose ingested alone greatly over-estimated the number of patients who need antidotes and it was a poor predictor of risk. Paracetamol concentrations by colorimetry are rapid and inexpensive. The use of these would greatly improve the assessment of risk and greatly reduce unnecessary expenditure on antidotes. PMID:23087506
Colorimetric microdetermination of captopril in pure form and in pharmaceutical formulations
NASA Astrophysics Data System (ADS)
Shama, Sayed Ahmed; El-Sayed Amin, Alla; Omara, Hany
2006-11-01
A simple, rapid, accurate, precise and sensitive colorimetric method for the determination of captopril (CAP) in bulk sample and in dosage forms is described. The method is based on oxidation of the drug by potassium permanganate in acidic medium and determination of the unreacted oxidant by measuring the decrease in absorbance for five different dyes; methylene blue (MB); acid blue 74 (AB), acid red 73 (AR), amaranth dye (AM) and acid orange 7 (AO) at a suitable λmax (660, 610, 510, 520, and 485 nm), respectively. Regression analysis of Beer's plots showed good correlation in the concentration ranges (0.4 12.5, 0.3 10, 0.5 11, 0.4 8.3 and 0.5 9.3 μg ml-1), respectively. The apparent molar absorbtivity, Sandell sensitivity, detection and quantitation limits were calculated. For more accurate results, Ringbom optimum concentration ranges were 0.5 12, 0.5 9.6, 0.6 10.5, 0.5 8.0 and 0.7 9.0 μg ml-1, respectively. The validity of the proposed method was tested by analyzing in pure and dosage forms containing CAP whether alone or in combination with hydrochlorothiazide. Statistical analysis of the results reflects that the proposed procedures are precise, accurate and easily applicable for the determination of CAP in pure form and in pharmaceutical preparations. Also, the stability constant was determined and the free energy change was calculated potentiometrically.
Swimley, Michelle S.; Taylor, Amber W.; Dawson, Erica D.
2011-01-01
Abstract Shiga toxin–producing Escherichia coli O157 is a leading cause of foodborne illness worldwide. To evaluate better methods to rapidly detect and genotype E. coli O157 strains, the present study evaluated the use of ampliPHOX, a novel colorimetric detection method based on photopolymerization, for pathogen identification with DNA microarrays. A low-density DNA oligonucleotide microarray was designed to target stx1 and stx2 genes encoding Shiga toxin production, the eae gene coding for adherence membrane protein, and the per gene encoding the O157-antigen perosamine synthetase. Results from the validation experiments demonstrated that the use of ampliPHOX allowed the accurate genotyping of the tested E. coli strains, and positive hybridization signals were observed for only probes targeting virulence genes present in the reference strains. Quantification showed that the average signal-to-noise ratio values ranged from 47.73 ± 7.12 to 76.71 ± 8.33, whereas average signal-to-noise ratio values below 2.5 were determined for probes where no polymer was formed due to lack of specific hybridization. Sensitivity tests demonstrated that the sensitivity threshold for E. coli O157 detection was 100–1000 CFU/mL. Thus, the use of DNA microarrays in combination with photopolymerization allowed the rapid and accurate genotyping of E. coli O157 strains. PMID:21288130
Akar, Zeynep; Küçük, Murat; Doğan, Hacer
2017-12-01
2,2-Diphenyl-1-picrylhydrazyl (DPPH • ) radical scavenging, the most commonly used antioxidant method with more than seventeen thousand articles cited, is very practical; however, as with most assays, it has the major disadvantage of dependence on a spectrophotometer. To overcome this drawback, the colorimetric determination of the antioxidant activity using a scanner and freely available Image J software was developed. In this new method, the mixtures of solutions of DPPH • and standard antioxidants or extracts of common medicinal herbs were dropped onto TLC plates, after an incubation period. The spot images were evaluated with Image J software to determine CSC 50 values, the sample concentrations providing 50% colour reduction, which were very similar with the SC 50 values obtained with spectrophotometric method. The advantages of the new method are the use of lower amounts of reagents and solvents, no need for costly spectrophotometers, and thus significantly lowered costs, and convenient implementation in any environment and situation.
Application of bacteriophages in sensor development.
Peltomaa, Riikka; López-Perolio, Irene; Benito-Peña, Elena; Barderas, Rodrigo; Moreno-Bondi, María Cruz
2016-03-01
Bacteriophage-based bioassays are a promising alternative to traditional antibody-based immunoassays. Bacteriophages, shortened to phages, can be easily conjugated or genetically engineered. Phages are robust, ubiquitous in nature, and harmless to humans. Notably, phages do not usually require inoculation and killing of animals; and thus, the production of phages is simple and economical. In recent years, phage-based biosensors have been developed featuring excellent robustness, sensitivity, and selectivity in combination with the ease of integration into transduction devices. This review provides a critical overview of phage-based bioassays and biosensors developed in the last few years using different interrogation methods such as colorimetric, enzymatic, fluorescence, surface plasmon resonance, quartz crystal microbalance, magnetoelastic, Raman, or electrochemical techniques.
Spectrophotometric total reducing sugars assay based on cupric reduction.
Başkan, Kevser Sözgen; Tütem, Esma; Akyüz, Esin; Özen, Seda; Apak, Reşat
2016-01-15
As the concentration of reducing sugars (RS) is controlled by European legislation for certain specific food and beverages, a simple and sensitive spectrophotometric method for the determination of RS in various food products is proposed. The method is based on the reduction of Cu(II) to Cu(I) with reducing sugars in alkaline medium in the presence of 2,9-dimethyl-1,10-phenanthroline (neocuproine: Nc), followed by the formation of a colored Cu(I)-Nc charge-transfer complex. All simple sugars tested had the linear regression equations with almost equal slope values. The proposed method was successfully applied to fresh apple juice, commercial fruit juices, milk, honey and onion juice. Interference effect of phenolic compounds in plant samples was eliminated by a solid phase extraction (SPE) clean-up process. The method was proven to have higher sensitivity and precision than the widely used dinitrosalicylic acid (DNS) colorimetric method. Copyright © 2015 Elsevier B.V. All rights reserved.
Needle Decompression of Tension Pneumothorax with Colorimetric Capnography.
Naik, Nimesh D; Hernandez, Matthew C; Anderson, Jeff R; Ross, Erika K; Zielinski, Martin D; Aho, Johnathon M
2017-11-01
The success of needle decompression for tension pneumothorax is variable, and there are no objective measures assessing effective decompression. Colorimetric capnography, which detects carbon dioxide present within the pleural space, may serve as a simple test to assess effective needle decompression. Three swine underwent traumatically induced tension pneumothorax (standard of care, n = 15; standard of care with needle capnography, n = 15). Needle thoracostomy was performed with an 8-cm angiocatheter. Similarly, decompression was performed with the addition of colorimetric capnography. Subjective operator assessment of decompression was recorded and compared with true decompression, using thoracoscopic visualization for both techniques. Areas under receiver operating curves were calculated and pairwise comparison was performed to assess statistical significance (P < .05). The detection of decompression by needle colorimetric capnography was found to be 100% accurate (15 of 15 attempts), when compared with thoracoscopic assessment (true decompression). Furthermore, it accurately detected the lack of tension pneumothorax, that is, the absence of any pathologic/space-occupying lesion, in 100% of cases (10 of 10 attempts). Standard of care needle decompression was detected by operators in 9 of 15 attempts (60%) and was detected in 3 of 10 attempts when tension pneumothorax was not present (30%). True decompression, under direct visualization with thoracoscopy, occurred 15 of 15 times (100%) with capnography, and 12 of 15 times (80%) without capnography. Areas under receiver operating curves were 0.65 for standard of care and 1.0 for needle capnography (P = .002). Needle decompression with colorimetric capnography provides a rapid, effective, and highly accurate method for eliminating operator bias for tension pneumothorax decompression. This may be useful for the treatment of this life-threatening condition. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
A continuous spectrophotometric assay method for peptidylarginine deiminase type 4 activity.
Liao, Ya-Fan; Hsieh, Hui-Chieh; Liu, Guang-Yaw; Hung, Hui-Chih
2005-12-15
A simple, continuous spectrophotometric assay for peptidylarginine deiminase (PAD) is described. Deimination of peptidylarginine results in the formation of peptidylcitrulline and ammonia. The ammonia released during peptidylarginine hydrolysis is coupled to the glutamate-dehydrogenase-catalyzed reductive amination of alpha-ketoglutarate to glutamate and reduced nicotinamide adenine dinucleotide (NADH) oxidation. The disappearance of absorbance at 340nm due to NADH oxidation is continuously measured. The specific activity obtained by this new protocol for highly purified human PAD is comparable to that obtained by a commonly used colorimetric procedure, which measures the ureido group of peptidylcitrulline by coupling with diacetyl monoxime. The present continuous spectrophotometric method is highly sensitive and accurate and is thus suitable for enzyme kinetic analysis of PAD. The Ca(2+) concentration for half-maximal activity of PAD obtained by this method is comparable to that previously obtained by the colorimetric procedure.
The colorimetric analysis of anti-tuberculosis fixed-dose combination tablets and capsules.
Ellard, G A
1999-11-01
The perceived need to demonstrate whether or not the actual amounts of rifampicin, isoniazid and pyrazinamide in fixed-dose combination tablets or capsules correspond to their stated drug contents. To adapt specific, robust and simple colorimetric methods that have been previously applied to measuring plasma and urinary rifampicin, isoniazid, pyrazinamide and ethambutol concentrations to estimate tablet and capsule drug contents. The methods were applied to the analysis of 14 commercially manufactured fixed-dose combinations: two capsule and three tablet formulations containing rifampicin and isoniazid; seven tablet formulations containing rifampicin, isoniazid and pyrazinamide; and two tablet formulations containing rifampicin, isoniazid, pyrazinamide and ethambutol. All the combined formulations contained near to their stated drug contents. Replicate analyses confirmed the excellent precision of the drug analyses. Such methods are not only rapid to perform but should be practical in many Third World situations with relatively modest laboratory facilities.
Deng, Jingjing; Shi, Guoyue; Zhou, Tianshu
2016-10-26
This study demonstrates a new strategy for colorimetric detection of alcoholic strength (AS) in spirit samples based on dual-responsive lanthanide infinite coordination polymer (Ln-ICP) particles with ratiometric fluorescence. The ICP used in this study are composed of two components: one is the supramolecular Ln-ICP network formed by the coordination between the ligand 2,2'-thiodiacetic acid (TDA) and central metal ion Eu 3+ ; and the other is a fluorescent dye, i.e., coumarin 343 (C343), both as the cofactor ligand and as the sensitizer, doped into the Ln-ICP network through self-adaptive chemistry. Upon being excited at 300 nm, the red fluorescence of Ln-ICP network itself at 617 nm is highly enhanced due to the concomitant energy transfer from C343 to Eu 3+ , while the fluorescence of C343 at 495 nm is supressed. In pure ethanol solvent, the as-formed C343@Eu-TDA is well dispersed and quite stable. However, the addition of water into ethanolic dispersion of C343@Eu-TDA destructs Eu-TDA network structure, resulting in the release of C343 from ICP network into the solvent. Consequently, the fluorescence of Eu-TDA turns off and the fluorescence of C343 turns on, leading to the fluorescent color change of the dispersion from red to blue, which constitutes a new mechanism for colorimetric sensing of AS in commercial spirit samples. With the method developed here, we could clearly distinguish the AS of different spirit samples within a wide linear range from 10% vol to 100% vol directly by "naked eye" with the help of UV-lamp (365 nm). This study not only offers a new method for on-the-spot visible detection of AS, but also provides a strategy for dual-responsive sensing mode by rational designing the optical properties of the Ln-ICP network and the guest, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Reconstruction of reflectance data using an interpolation technique.
Abed, Farhad Moghareh; Amirshahi, Seyed Hossein; Abed, Mohammad Reza Moghareh
2009-03-01
A linear interpolation method is applied for reconstruction of reflectance spectra of Munsell as well as ColorChecker SG color chips from the corresponding colorimetric values under a given set of viewing conditions. Hence, different types of lookup tables (LUTs) have been created to connect the colorimetric and spectrophotometeric data as the source and destination spaces in this approach. To optimize the algorithm, different color spaces and light sources have been used to build different types of LUTs. The effects of applied color datasets as well as employed color spaces are investigated. Results of recovery are evaluated by the mean and the maximum color difference values under other sets of standard light sources. The mean and the maximum values of root mean square (RMS) error between the reconstructed and the actual spectra are also calculated. Since the speed of reflectance reconstruction is a key point in the LUT algorithm, the processing time spent for interpolation of spectral data has also been measured for each model. Finally, the performance of the suggested interpolation technique is compared with that of the common principal component analysis method. According to the results, using the CIEXYZ tristimulus values as a source space shows priority over the CIELAB color space. Besides, the colorimetric position of a desired sample is a key point that indicates the success of the approach. In fact, because of the nature of the interpolation technique, the colorimetric position of the desired samples should be located inside the color gamut of available samples in the dataset. The resultant spectra that have been reconstructed by this technique show considerable improvement in terms of RMS error between the actual and the reconstructed reflectance spectra as well as CIELAB color differences under the other light source in comparison with those obtained from the standard PCA technique.
Vidya, Raj; Saji, Alex
2018-05-01
The development of an easy to use, one-pot, environmentally friendly, non-invasive and label-free colorimetric probe for the determination of semen protamines, the biochemical marker of male fertility, using heparin gold nanoparticles (HAuNPs) is presented. The affinity of HAuNPs for protamines was due to the electrostatic interactions between polycationic protamine and polyanionic heparin. The binding of HAuNPs to protamine was characterized by variation in the plasmon absorption spectra followed by a visibly observable colour change of the solution from red to blue. We observed a red shift in the plasmon peak and the method exhibited linearity in the range of 10-70 ng/mL with a detection limit of 5 ng/mL, which is much lower than that reported for colorimetric sensors of protamine. The colour change and the variation in the absorbance of HAuNPs were highly specific for protamines in the presence of different interfering compounds and the method was successfully applied for determining protamine in real samples of semen and serum. Rather than a quantitative estimation, it seems that the method provides a quick screening between a large array of positive and negative samples and, moreover, it maintains the privacy of the user. The method appears to be simple and would be very useful in third-world countries where high-tech diagnostic aids are inaccessible to the majority of the population. Graphical Abstract Heparin gold nanoparticles aided visual detection of infertility.
Colorimetric detection of melamine based on p-chlorobenzenesulfonic acid-modified AuNPs
NASA Astrophysics Data System (ADS)
Li, Jianfang; Huang, Pengcheng; Wu, Fangying
2016-06-01
A highly selective and sensitive method is developed for colorimetric detection of melamine using gold nanoparticles (AuNPs) functionalized with p-chlorobenzenesulfonic acid. The addition of melamine induced the aggregation of AuNPs, as evidenced from the morphological characterizations and the color changed from red wine to blue, which could also be monitored by the UV-visible spectrometer and even naked eyes. This process caused a significant increase in the absorbance ratio (A650nm/A520nm) of p-chlorobenzenesulfonic acid-AuNPs. Under optimized conditions, the system exhibited a linear response to melamine in the range of 6.0 × 10-7-1.5 × 10-6 mol L-1 with a correlation coefficient of 0.997, and the limit of detection can even be 2.3 nM, which was much lower than some other methods and the safe limits (20 μM in both the USA and EU, 8.0 μM for infant formula in China, 1.2 μM in the CAC (Codex Alimentarius Commission) review for melamine in liquid infant formula). More importantly, the developed method presented excellent tolerance to coexisting common metal ions such as Ca2+, Zn2+, whose concentration is 1000 times of melamine, so that it had been applied to the analysis of melamine in liquid milk and milk powder with the recovery of 97.0-101 % and 100-103 %, respectively, indicating that the proposed method is quite a highly effective means to determine melamine in milk products.
A paper-based Colorimetric Indicator Label using Natural Dye for Monitoring Shrimp Spoilage
NASA Astrophysics Data System (ADS)
Listyarini, A.; Sholihah, W.; Imawan, C.
2018-05-01
Shrimp is a type of perishable food. This study developed a simple indicator label using colorimetric method for monitoring shrimp freshness. This indicator label was made from natural dye extract of Ruellia simplex flowers which immobilized on cellulose paper by dip coating method. The indicator labels were used for examining freshness of shrimp. In this experiment, shrimp were stored in sealed bottles that have been labeled using the indicator and stored at 13 °C, 25 °C, and 40 °C for a certain range of time. Color changes of the indicator labels were observed using digital photography after shrimp storage for 0 h, 2 h, 17 h and 24 h. The color changes that occur were quantified and analyzed using the ImageJ program. The color of the indicator label when detecting the fresh shrimp was pink and after the shrimp spoilage began, the color of the label changed to purple and then became yellow when the shrimp is badly spoilage. The color change rates of label indicator increases as the shrimp storage temperature increased. These results indicate that this label indicator can be used as an indicator of the freshness of shrimps and it is not toxic and safe for food.
NASA Astrophysics Data System (ADS)
Wachiralurpan, Sirirat; Sriyapai, Thayat; Areekit, Supatra; Sriyapai, Pichapak; Augkarawaritsawong, Suphitcha; Santiwatanakul, Somchai; Chansiri, Kosum
2018-04-01
ABSTRACT Listeria monocytogenes is a major foodborne pathogen of global health concern. Herein, the rapid diagnosis of L. monocytogenes has been achieved using loop-mediated isothermal amplification (LAMP) based on the phosphatidylcholine-phospholipase C gene (plcB). Colorimetric detection was then performed through the formation of DNA concatemers and a gold nanoparticle/DNA probe complex (GNP/DNA probe). The overall detection process was accomplished within approximately 1 h with no need for complicated equipment. The limits of detection for L. monocytogenes in the forms of purified genomic DNA and pure culture were 800 fg and 2.82 CFU mL-1, respectively. No cross reactions were observed from closely related bacteria species. The LAMP-GNP/DNA probe assay was applied to the detection of 200 raw chicken meat samples and compared to routine standard methods. The data revealed that the specificity, sensitivity and accuracy were 100%, 90.20% and 97.50%, respectively. The present assay was 100% in conformity with LAMP-agarose gel electrophoresis assay. Five samples that were negative by both assays appeared to have the pathogen at below the level of detection. The assay can be applied as a rapid direct screening method for L. monocytogenes.
Colorimetric detection of DNA damage by using hemin-graphene nanocomposites
NASA Astrophysics Data System (ADS)
Wei, W.; Zhang, D. M.; Yin, L. H.; Pu, Y. P.; Liu, S. Q.
2013-04-01
A colorimetric method for detection of DNA damage was developed by using hemin-graphene nanosheets (H-GNs). H-GNs were skillfully synthesized by adsorping of hemin on graphene through π-π interactions. The as-prepared H-GNs possessed both the ability of graphene to differentiate the damage DNA from intact DNA and the catalytic action of hemin. The damaged DNA made H-GNs coagulated to different degrees from the intact DNA because there were different amount of negative charge exposed on their surface, which made a great impact on the solubility of H-GNs. As a result, the corresponding centrifugal supernatant of H-GNs solution showed different color in the presence of 3,3',5,5'-tetramethylbenzidine (TMB) and H2O2, which could be discriminated by naked eyes or by ultraviolet (UV)-visible spectrometer. Based on this, the damaged effects of styrene oxide (SO), NaAsO2 and UV radiation on DNA were studied. Results showed that SO exerted most serious damage effect on DNA although all of them damaged DNA seriously. The new method for detection of DNA damage showed good prospect in the evaluation of genotoxicity of new compounds, the maximum limit of pesticide residue, food additives, and so on, which is important in the fields of food science, pharmaceutical science and pesticide science.
[Photometric determination of captopril using label-free silver nanoparticles].
Li, Rui; Yan, Hong-Tao
2013-04-01
A simple, rapid and sensitive colorimetric method for the determination of captopril is presented in the present paper. It is based on the fact that captopril can induce the aggregation of AgNPs, thereby resulting in their yellow-to-red color change and the absorbance decrease at lambda395 nm. The mechanism of the aggregation effect was discussed in detail. Under the optimized conditions, the linear range of determination of captopril was 1-35 microg x mL(-1) with correction coefficient 0.998 4. The detection limit of the method for captopril was 0.7 microg x mL(-1). The method has been applied to the determination of captopril in tablets with satisfactory result.
Lee, Juhyen; Choi, Eun Jung; Kim, Inwon; Lee, Minhe; Satheeshkumar, Chinnadurai; Song, Changsik
2017-01-01
Tuning the sensing properties of spiropyrans (SPs), which are one of the photochromic molecules useful for colorimetric sensing, is important for efficient analysis, but their synthetic modification is not always simple. Herein, we introduce an alkyne-functionalized SP, the modification of which would be easily achieved via Cu-catalyzed azide-alkyne cycloaddition (“click reaction”). The alkyne-SP was conjugated with a bis(triethylene glycol)-benzyl group (EG-BtSP) or a simple benzyl group (BtSP), forming a triazole linkage from the click reaction. The effects of auxiliary groups to SP were tested on metal-ion sensing and cyanide detection. We found that EG-BtSP was more Ca2+-sensitive than BtSP in acetonitrile, which were thoroughly examined by a continuous variation method (Job plot) and UV-VIS titrations, followed by non-linear regression analysis. Although both SPs showed similar, selective responses to cyanide in a water/acetonitrile co-solvent, only EG-BtSP showed a dramatic color change when fabricated on paper, highlighting the important contributions of the auxiliary groups. PMID:28783127
Fluoride-selective colorimetric sensor based on thiourea binding site and anthraquinone reporter.
Wu, Fang-ying; Hu, Mei-hua; Wu, Yu-mei; Tan, Xiao-fang; Zhao, Yong-qiang; Ji, Zhao-jun
2006-11-01
A structurally simple colorimetric sensor, N-4-nitrobenzene-N'-1'-anthraquinone-thiourea (1), for anions was synthesized and characterized by (1)H NMR, ESI mass and IR methods. In acetonitrile, the addition of F(-) changed 1 solution from colorless to yellow. In the presence of other anions such as CH(3)CO(2)(-), H(2)PO(4)(-), HSO(4)(-) and Cl(-), however, the absorption spectrum of 1 was slightly red shifted with no obvious color changes observed. The association constants of anionic complexes followed the order of F(-)>CH(3)CO(2)(-)>H(2)PO(4)(-)>HSO(4)(-)>Cl(-)>Br(-), which was different from the order of anion basicity. AM1 calculation results indicated that the most stable configuration of 1 existed in the Z-E-conformation with a six-membered ring via intramolecular hydrogen bond. This made thiourea moiety of 1 in an unfavorable conformation to bond with oxygen-anionic substrates such as CH(3)CO(2)(-) and H(2)PO(4)(-), thus leading to a high selectivity and sensitivity for the detection of F(-).
Novel colorimetric sensors for cyanide based on azo-hydrazone tautomeric skeletons.
Adegoke, Olajire A; Adesuji, Temitope E; Thomas, Olusegun E
2014-07-15
The monoazo dyes, 4-carboxyl-2, 6-dinitrophenylazohydroxynaphthalenes dyes (AZ-01, AZ-03 and AZ-04), were evaluated as a highly selective colorimetric chemosensor for cyanide ion. The recognition of cyanide ion gave an obvious colour change from light yellow to brownish red and upon dilution with acetone produced a purple to lilac colour. Optimum conditions for the reaction between the azo dyes and cyanide ion were established at 30°C for 5 min, and different variables affecting the reaction were carefully studied and optimised. Under the optimum conditions, linear relationships between the CN(-) concentrations and light absorption were established. Using these azo-hydrazone molecular switch entities, excellent selectivity towards the detection of CN(-) in aqueous solution over miscellaneous competitive anions was observed. Such selectivity mainly results from the possibility of nucleophilic attack on the azo-hydrazone chemosensors by cyanide anions in aqueous system, which is not afforded by other competing anions. The cyanide chemosensor method described here should have potential application as a new family probes for detecting cyanide in aqueous solution. Copyright © 2014 Elsevier B.V. All rights reserved.
Ramezani, Mohammad; Mohammad Danesh, Noor; Lavaee, Parirokh; Abnous, Khalil; Mohammad Taghdisi, Seyed
2015-08-15
Detection methods of antibiotic residues in blood serum and animal derived foods are of great interest. In this study a colorimetric aptasensor was designed for sensitive, selective and fast detection of tetracycline based on triple-helix molecular switch (THMS) and gold nanoparticles (AuNPs). As a biosensor, THMS shows distinct advantages including high stability, sensitivity and preserving the selectivity and affinity of the original aptamer. In the absence of tetracycline, THMS is stable, leading to the aggregation of AuNPs by salt and an obvious color change from red to blue. In the presence of tetracycline, aptamer binds to its target, signal transduction probe (STP) leaves the THMS and adsorbs on the surface of AuNPs. So the well-dispersed AuNPs remain stable against salt-induced aggregation with a red color. The presented aptasensor showed high selectivity toward tetracyclines with a limit of detection as low as 266 pM for tetracycline. The designed aptasensor was successfully applied to detect tetracycline in serum and milk. Copyright © 2015 Elsevier B.V. All rights reserved.
Prediction of warmed-over flavour development in cooked chicken by colorimetric sensor array.
Kim, Su-Yeon; Li, Jinglei; Lim, Na-Ri; Kang, Bo-Sik; Park, Hyun-Jin
2016-11-15
The aim of this study was to develop a simple and rapid method based on colorimetric sensor array (CSA) for evaluation of warmed-over flavour (WOF) in cooked chicken. All samples were classified according to storage time by CSA coupled with principle component analysis (PCA) or hierarchical cluster analysis (HCA). The CSA data were used to establish prediction models with thiobarbituric acid reactive substances (TBARS), pentanal, hexanal, or heptanal associated with WOF by partial least square regression (PLSR). For the TBARS model, the coefficient of determination (rp(2)) was 0.9997 in the prediction range of 0.28-0.69mg/kg. In each of the models for pentanal, hexanal, and heptanal, all rp(2) were higher than 0.960 in the range of 0.58-2.10mg/kg, 5.50-11.69mg/kg, and 0.09-0.16mg/kg, respectively. These results demonstrate that the CSA was able to predict WOF development and to distinguish between each storage time. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Deka, Jashmini; Mojumdar, Aditya; Parisse, Pietro; Onesti, Silvia; Casalis, Loredana
2017-03-01
Helicase are essential enzymes which are widespread in all life-forms. Due to their central role in nucleic acid metabolism, they are emerging as important targets for anti-viral, antibacterial and anti-cancer drugs. The development of easy, cheap, fast and robust biochemical assays to measure helicase activity, overcoming the limitations of the current methods, is a pre-requisite for the discovery of helicase inhibitors through high-throughput screenings. We have developed a method which exploits the optical properties of DNA-conjugated gold nanoparticles (AuNP) and meets the required criteria. The method was tested with the catalytic domain of the human RecQ4 helicase and compared with a conventional FRET-based assay. The AuNP-based assay produced similar results but is simpler, more robust and cheaper than FRET. Therefore, our nanotechnology-based platform shows the potential to provide a useful alternative to the existing conventional methods for following helicase activity and to screen small-molecule libraries as potential helicase inhibitors.
ERIC Educational Resources Information Center
Kleppinger, E. W.; And Others
1984-01-01
Although determination of phosphorus is important in biology, physiology, and environmental science, traditional gravimetric and colorimetric methods are cumbersome and lack the requisite sensitivity. Therefore, a derivative activation analysis method is suggested. Background information, procedures, and results are provided. (JN)
Fretellier, Nathalie; Poteau, Nathalie; Factor, Cécile; Mayer, Jean-François; Medina, Christelle; Port, Marc; Idée, Jean-Marc; Corot, Claire
2014-01-01
Objectives The purposes of this study were to evaluate the risk for analytical interference with gadolinium-based contrast agents (GBCAs) for the colorimetric measurement of serum iron (Fe3+) and to investigate the mechanisms involved. Materials and Methods Rat serum was spiked with several concentrations of all molecular categories of GBCAs, ligands, or “free” soluble gadolinium (Gd3+). Serum iron concentration was determined by 2 different colorimetric methods at pH 4.0 (with a Vitros DT60 analyzer or a Cobas Integra 400 analyzer). Secondly, the cause of interference was investigated by (a) adding free soluble Gd3+ or Mn2+ to serum in the presence of gadobenic acid or gadodiamide and (b) electrospray ionization mass spectrometry. Results Spurious decrease in serum Fe3+ concentration was observed with all linear GBCAs (only with the Vitros DT60 technique occurring at pH 4.0) but not with macrocyclic GBCAs or with free soluble Gd3+. Spurious hyposideremia was also observed with the free ligands present in the pharmaceutical solutions of the linear GBCAs gadopentetic acid and gadodiamide (ie, diethylene triamine pentaacetic acid and calcium-diethylene triamine pentaacetic acid bismethylamide, respectively), suggesting the formation of Fe-ligand chelate. Gadobenic acid-induced interference was blocked in a concentration-dependent fashion by adding a free soluble Gd3+ salt. Conversely, Mn2+, which has a lower affinity than Gd3+ and Fe3+ for the ligand of gadobenic acid (ie, benzyloxypropionic diethylenetriamine tetraacetic acid), was less effective (interference was only partially blocked), suggesting an Fe3+ versus Gd3+ transmetallation phenomenon at pH 4.0. Similar results were observed with gadodiamide. Mass spectrometry detected the formation of Fe-ligand with all linear GBCAs tested in the presence of Fe3+ and the disappearance of Fe-ligand after the addition of free soluble Gd3+. No Fe-ligand chelate was found in the case of the macrocyclic GBCA gadoteric acid. Conclusions Macrocyclic GBCAs induced no interference with colorimetric methods for iron determination, whereas negative interference was observed with linear GBCAs using a Vitros DT60 analyzer. This interference of linear GBCAs seems to be caused by the excess of ligand and/or an Fe3+ versus Gd3+ transmetallation phenomenon. PMID:24943092
Gao, Bingbing; Liu, Hong; Gu, Zhongze
2014-12-23
We report a method for the bottom-up fabrication of paper-based capillary microchips by the blade coating of cellulose microfibers on a patterned surface. The fabrication process is similar to the paper-making process in which an aqueous suspension of cellulose microfibers is used as the starting material and is blade-coated onto a polypropylene substrate patterned using an inkjet printer. After water evaporation, the cellulose microfibers form a porous, hydrophilic, paperlike pattern that wicks aqueous solution by capillary action. This method enables simple, fast, inexpensive fabrication of paper-based capillary channels with both width and height down to about 10 μm. When this method is used, the capillary microfluidic chip for the colorimetric detection of glucose and total protein is fabricated, and the assay requires only 0.30 μL of sample, which is 240 times smaller than for paper devices fabricated using photolithography.
DNAzyme based gap-LCR detection of single-nucleotide polymorphism.
Zhou, Li; Du, Feng; Zhao, Yongyun; Yameen, Afshan; Chen, Haodong; Tang, Zhuo
2013-07-15
Fast and accurate detection of single-nucleotide polymorphism (SNP) is thought more and more important for understanding of human physiology and elucidating the molecular based diseases. A great deal of effort has been devoted to developing accurate, rapid, and cost-effective technologies for SNP analysis. However most of those methods developed to date incorporate complicated probe labeling and depend on advanced equipment. The DNAzyme based Gap-LCR detection method averts any chemical modification on probes and circumvents those problems by incorporating a short functional DNA sequence into one of LCR primers. Two kinds of exonuclease are utilized in our strategy to digest all the unreacted probes and release the DNAzymes embedded in the LCR product. The DNAzyme applied in our method is a versatile tool to report the result of SNP detection in colorimetric or fluorometric ways for different detection purposes. Copyright © 2013 Elsevier B.V. All rights reserved.
Current status of antifungal susceptibility testing methods.
Arikan, Sevtap
2007-11-01
Antifungal susceptibility testing is a very dynamic field of medical mycology. Standardization of in vitro susceptibility tests by the Clinical and Laboratory Standards Institute (CLSI) and the European Committee for Antimicrobial Susceptibility Testing (EUCAST), and current availability of reference methods constituted the major remarkable steps in the field. Based on the established minimum inhibitory concentration (MIC) breakpoints, it is now possible to determine the susceptibilities of Candida strains to fluconazole, itraconazole, voriconazole, and flucytosine. Moreover, utility of fluconazole antifungal susceptibility tests as an adjunct in optimizing treatment of candidiasis has now been validated. While the MIC breakpoints and clinical significance of susceptibility testing for the remaining fungi and antifungal drugs remain yet unclear, modifications of the available methods as well as other methodologies are being intensively studied to overcome the present drawbacks and limitations. Among the other methods under investigation are Etest, colorimetric microdilution, agar dilution, determination of fungicidal activity, flow cytometry, and ergosterol quantitation. Etest offers the advantage of practical application and favorable agreement rates with the reference methods that are frequently above acceptable limits. However, MIC breakpoints for Etest remain to be evaluated and established. Development of commercially available, standardized colorimetric panels that are based on CLSI method parameters has added more to the antifungal susceptibility testing armamentarium. Flow cytometry, on the other hand, appears to offer rapid susceptibility testing but requires specified equipment and further evaluation for reproducibility and standardization. Ergosterol quantitation is another novel approach, which appears potentially beneficial particularly in discrimination of azole-resistant isolates from heavy trailers. The method is yet investigational and requires to be further studied. Developments in methodology and applications of antifungal susceptibility testing will hopefully provide enhanced utility in clinical guidance of antifungal therapy. However, and particularly in immunosuppressed host, in vitro susceptibility is and will remain only one of several factors that influence clinical outcome.
Interfacial Polymerization for Colorimetric Labeling of Protein Expression in Cells
Lilly, Jacob L.; Sheldon, Phillip R.; Hoversten, Liv J.; Romero, Gabriela; Balasubramaniam, Vivek; Berron, Brad J.
2014-01-01
Determining the location of rare proteins in cells typically requires the use of on-sample amplification. Antibody based recognition and enzymatic amplification is used to produce large amounts of visible label at the site of protein expression, but these techniques suffer from the presence of nonspecific reactivity in the biological sample and from poor spatial control over the label. Polymerization based amplification is a recently developed alternative means of creating an on-sample amplification for fluorescence applications, while not suffering from endogenous labels or loss of signal localization. This manuscript builds upon polymerization based amplification by developing a stable, archivable, and colorimetric mode of amplification termed Polymer Dye Labeling. The basic concept involves an interfacial polymer grown at the site of protein expression and subsequent staining of this polymer with an appropriate dye. The dyes Evans Blue and eosin were initially investigated for colorimetric response in a microarray setting, where both specifically stained polymer films on glass. The process was translated to the staining of protein expression in human dermal fibroblast cells, and Polymer Dye Labeling was specific to regions consistent with desired protein expression. The labeling is stable for over 200 days in ambient conditions and is also compatible with modern mounting medium. PMID:25536421
Fan, Jiao-Rong; Zhu, Jia; Wu, Wen-Gang; Huang, Yun
2017-01-01
In view of the toxic potential of a bioweapon threat, rapid visual recognition and sensing of ricin has been of considerable interest while remaining a challenging task up to date. In this study, a gold nanopin-based colorimetric sensor is developed realizing a multicolor variation for ricin qualitative recognition and analysis. It is revealed that such plasmonic metasurfaces based on nanopin-cavity resonator exhibit reflective color appearance, due to the excitation of standing-wave resonances of narrow bandwidth in visible region. This clear color variation is a consequence of the reflective color mixing defined by different resonant wavelengths. In addition, the colored metasurfaces appear sharp color difference in a narrow refractive index range, which makes them especially well-suited for sensing applications. Therefore, this antibody-functionalized nanopin-cavity biosensor features high sensitivity and fast response, allowing for visual quantitative ricin detection within the range of 10-120 ng mL -1 (0.15 × 10 -9 -1.8 × 10 -9 m), a limit of detection of 10 ng mL -1 , and the typical measurement time of less than 10 min. The on-chip integration of such nanopin metasurfaces to portable colorimetric microfluidic device may be envisaged for the quantitative studies of a variety of biochemical molecules. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lai, Wenqiang; Zeng, Qiao; Tang, Juan; Zhang, Maosheng; Tang, Dianping
2018-01-10
The authors describe a colorimetric immunoassay for the model nalyte aflatoxin B 1 (AFB 1 ). It is based on the just-in-time generation of an MnO 2 nanocatalyst. Unlike previously developed immunoassay, the chromogenic reaction relies on the just-in-time formation of an oxidase mimic without the aid of the substrate. Potassium permanganate (KMnO 4 ) is converted into manganese dioxide (MnO 2 ) which acts as an oxidase mimic that catalyzes the oxidation 3,3',5,5'-tetramethylbenzidine (TMB) by oxygen to give a blue colored product. In the presence of ascorbic acid (AA), KMnO 4 is reduced to Mn(II) ions. This results in a decrease in the amount of MnO 2 nanocatalyst. Hence, the oxidation of TMB does not take place. By adding ascorbate oxidase, AA is converted into dehydroascorbic acid which cannot reduce KMnO 4 . Based on these observations, a colorimetric competitive enzyme immunoassay was developed where ascorbate oxidase and gold nanoparticle-labeled antibody against AFB 1 and magnetic beads carrying bovine serum albumin conjugated to AFB 1 are used for the determination of AFB 1 . In presence of AFB 1 , it will compete with the BSA-conjugated AFB 1 (on the magnetic beads) for the labeled antibody against AFB 1 on the gold nanoparticles. This makes the amount of ascorbate oxidase/anti-AFB 1 antibody-labeled gold nanoparticles, which conjugated on magnetic beads, reduce, and resulted in an increase of ascorbic acid. Under optimal conditions, the absorbance (measured at 652 nm) decreases with increasing AFB 1 concentrations in the range from 0.1 to 100 ng mL -1 , with a 0.1 ng mL -1 detection limit (at the 3S blank level). The accuracy of the assay was validated by analyzing spiked peanut samples. The results matched well with those obtained with a commercial ELISA kit. Conceivably, the method is not limited to aflatoxins but has a wide scope in that it may be applied to many other analytes for which respective antibodies are available. Graphical abstract Schematic illustration of ascorbate oxidase (AOx)-mediated potassium permanganate (KMnO 4 )-responsive ascorbic acid (AA) for visual colorimetric immunoassay of aflatoxin B 1 (AFB 1 ) by coupling with hydrolytic reaction of AOx toward AA and the KMnO 4 -Mn(II)-TMB system [note: 3,3',5,5'-tetramethylbenzidine: TMB].
Colorimetric consideration of transparencies for a typical LACIE scene
NASA Technical Reports Server (NTRS)
Juday, R. D. (Principal Investigator)
1979-01-01
The production film converter used to produce LACIE imagery is described as well as schemes designed to provide the analyst with operational film products. Two of these products are discussed from the standpoint of color theory. Colorimetric terminology is defined and the mathematical calculations are given. Topics covered include (1) history of product 1 and 3 algorithm development; (2) colorimetric assumptions for product 1 and 3 algorithms; (3) qualitative results from a colorimetric analysis of a typical LACIE scene; and (4) image-to-image color stability.
Senarathna, S M D K Ganga; Ranganathan, Shalini S; Buckley, Nick; Soysa, S S S B D Preethi; Fernandopulle, B M Rohini
2012-01-01
Acute paracetamol poisoning is an emerging problem in Sri Lanka. Management guidelines recommend ingested dose and serum paracetamol concentrations to assess the risk. Our aim was to determine the usefulness of the patient's history of an ingested dose of >150 mg/kg and paracetamol concentration obtained by a simple colorimetric method to assess risk in patients with acute paracetamol poisoning. Serum paracetamol concentrations were determined in 100 patients with a history of paracetamol overdose using High Performance Liquid Chromatography (HPLC); (reference method). The results were compared to those obtained with a colorimetric method. The utility of risk assessment by reported dose ingested and colorimetric analysis were compared. The area under the receiver operating characteristic curve for the history of ingested dose was 0.578 and there was no dose cut-off providing useful risk categorization. Both analytical methods had less than 5% intra- and inter-batch variation and were accurate on spiked samples. The time from blood collection to result was six times faster and ten times cheaper for colorimetry (30 minutes, US$2) than for HPLC (180 minutes, US$20). The correlation coefficient between the paracetamol levels by the two methods was 0.85. The agreement on clinical risk categorization on the standard nomogram was also good (Kappa = 0.62, sensitivity 81%, specificity 89%). History of dose ingested alone greatly over-estimated the number of patients who need antidotes and it was a poor predictor of risk. Paracetamol concentrations by colorimetry are rapid and inexpensive. The use of these would greatly improve the assessment of risk and greatly reduce unnecessary expenditure on antidotes.
Colorimetric sensing of selenocystine using gold nanoparticles.
Liu, Liyang; Wang, Xia; Yang, Juan; Bai, Yan
2017-10-15
We present a highly selective and sensitive colorimetric method for the detection of selenocystine (SeCys) coexisting with other amino acids, especially cysteine (Cys) using the gold nanoparticles (AuNPs). Firstly, Cys was oxidized to cystine (Cys-Cys) by dissolved oxygen under Cu 2+ catalysis in the pre-reaction, which eliminated the interference of Cys in the SeCys sensing process. Then SeCys induced the rapid aggregation of AuNPs through Au-Se bond and complex formation of Cu 2+ -SeCys in the colorimetric reaction, in which the color change of AuNPs from red to blue or purple with the naked eye detection or with a UV-vis spectrophotometric determination. The concentration of SeCys was quantified by the value at 670 nm from the second-derivative SPR absorbance spectrum. The linear range was from 2 μM to 14 μM with correlation coefficient of 0.999 and a detection limit (LOD) was 0.14 μM. Moreover, the colorimetric response of AuNPs exhibited remarkable specificity to SeCys coexisting with 18 amino acids in a simulation sample, in which the total concentration of Cys and Cys-Cys was less than 15 μM and the each concentration of other 16 common amino acids was 10 μM. Copyright © 2017 Elsevier Inc. All rights reserved.
The effect of carbonated beverages on colorimetric end-tidal CO(2) determination
Qureshi; Park; Sturmann; Hsu
2000-10-01
Esophageal intubation is a significant complication of attempted airway control. Colorimetric end-tidal CO(2) monitors are highly sensitive and specific for detecting the presence of CO(2). There are reports of false-positive end-tidal CO(2) readings from esophageal intubations in patients who had ingested carbonated beverages. OBJECTIVE: To determine whether carbonated gastric contents can affect colorimetric end-tidal CO(2) readings. METHODS: End-tidal CO(2) was measured in sacrificed piglets at measured time intervals after instillation of 5-, 10-, 15-, and 20-mL aliquots of Diet Coke were placed into the stomach via a 28-French orogastric tube followed by esophageal intubation. The stomach was completely evacuated prior to each instillation and rechecked for baseline CO(2). RESULTS: Compiled data from three piglets (20-30 kg). Piglets were not ventilated or moved and determinations were measured at 20 degrees while supine. All data collected within 2 hours postmortem (table 24-1). CONCLUSIONS: The colorimetric end-tidal CO(2) turned "yellow" and did not change to blue with extended insufflations. The CO(2) of a small quantity of carbonated beverage in the stomach could be "blown off" by multiple insufflations. We conclude that esophageal intubation in the setting of recent ingestion of a carbonated beverage may result in a false-positive end-tidal CO(2) determination.
Influence of VO2 Nanoparticle Morphology on the Colorimetric Assay of H2O2 and Glucose
Tian, Rui; Sun, Jiaheng; Qi, Yanfei; Zhang, Boyu; Guo, Shuanli; Zhao, Mingming
2017-01-01
Nanozyme-based colorimetric sensors have received considerable attention due to their unique properties. The size, shape, and surface chemistry of these nanozymes could dramatically influence their sensing behaviors. Herein, a comparative study of VO2 nanoparticles with different morphologies (nanofibers, nanosheets, and nanorods) was conducted and applied to the sensitive colorimetric detection of H2O2 and glucose. The peroxidase-like activities and mechanisms of VO2 nanoparticles were analyzed. Among the VO2 nanoparticles, VO2 nanofibers exhibited the best peroxidase-like activity. Finally, a comparative quantitative detections of H2O2 and glucose were done on fiber, sheet, and rod nanoparticles. Under the optimal reaction conditions, the lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for H2O2 are found to be 0.018, 0.266, and 0.41 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for H2O2 from 0.025–10, 0.488–62.5, and 0.488–15.625 mM, respectively. The lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for glucose are found to be 0.009, 0.348, and 0.437 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for glucose from 0.01–10, 0.625–15, and 0.625–10 mM, respectively. The proposed work will contribute to the nanozyme-based colorimetric assay. PMID:29068412
8-Hydroxyquinoline based push-pull azo dye: Novel colorimetric chemosensor for anion detection
NASA Astrophysics Data System (ADS)
Arslan, Ömer; Aydıner, Burcu; Yalçın, Ergin; Babür, Banu; Seferoğlu, Nurgül; Seferoğlu, Zeynel
2017-12-01
A novel colorimetric chemosensor based on push-pull dye (8HQA) was synthesized and characterized by using IR, 1H/13C NMR and HRMS for the purpose of recognition of anions and cations in DMSO. The absorption maxima of the chemosensor were determined in different solvents. The selectivity and sensitivity of 8HQA to anions were determined with spectrophotometric and 1H NMR titration techniques. The selectivity of 8HQA for studied anions (CN-, F-, Cl-, I-, AcO-, HSO4- and H2PO4-) was determined in DMSO. There is no selectivity between competing anions such as CN-, F- AcO- and H2PO4- at the stoichiometric ratio of 1:1 in UV-vis titrations experiments however, it was observed different color changes upon addition of CN-, F-, AcO- and H2PO4- to the DMSO solution. In addition, the chemosensor showed no colorimetric response for the following anions; Cl-, I- and HSO4- in DMSO. The colorimetric sensing ability of 8HQA was studied in the presence of chloride salts of different cations such as Ca2+, Mg2+, Cu2+, Co2+, Sn2+, Ni2+, Cd2+ and Hg2+. Upon the addition of 4 equiv of each of the cations showed bathochromic shifts except for Ca2+and Cu2+. Interestingly, no selectivity was observed in interaction with metal cations. In addition, the molecular and electronic structures of 8HQA, as well as the molecular complexes of 8HQA, formed with the anions, were obtained theoretically and confirmed by DFT and TD-DFT calculations.
Zhang, Shi-Xiang; Xue, Shi-Fan; Deng, Jingjing; Zhang, Min; Shi, Guoyue; Zhou, Tianshu
2016-11-15
It is important and urgent to develop reliable and highly sensitive methods that can provide on-site and rapid detection of extensively used organophosphorus pesticides (OPs) for their neurotoxicity. In this study, we developed a novel colorimetric assay for the detection of OPs based on polyacrylic acid-coated cerium oxide nanoparticles (PAA-CeO2) as an oxidase mimic and OPs as inhibitors to suppress the activity of acetylcholinesterase (AChE). Firstly, highly dispersed PAA-CeO2 was prepared in aqueous solution, which could catalyze the oxidation of TMB to produce a color reaction from colorless to blue. And the enzyme of AChE was used to catalyze the substrate of acetylthiocholine (ATCh) to produce thiocholine (TCh). As a thiol-containing compound with reducibility, TCh can decrease the oxidation of TMB catalyzed by PAA-CeO2. Upon incubated with OPs, the enzymatic activity of AChE was inhibited to produce less TCh, resulting in more TMB catalytically oxidized by PAA-CeO2 to show an increasing blue color. The two representative OPs, dichlorvos and methyl-paraoxon, were tested using our proposed assay. The novel assay showed notable color change in a concentration-dependent manner, and as low as 8.62 ppb dichlorvos and 26.73 ppb methyl-paraoxon can be readily detected. Therefore, taking advantage of such oxidase-like activity of PAA-CeO2, our proposed colorimetric assay can potentially be a screening tool for the precise and rapid evaluation of the neurotoxicity of a wealth of OPs. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Shuwen; Xu, Naihan; Tan, Chunyan; Fang, Wei; Tan, Ying; Jiang, Yuyang
2018-08-14
In this study, a novel colorimetric aptasensor was prepared by coupling trivalent peroxidase-mimic DNAzyme and magnetic nanoparticles for highly sensitive and selective detection of target proteins. A three G-quadruplex (G4) DNA-hemin complex was employed as the trivalent peroxidase-mimic DNAzyme, in which hemin assisted the G4-DNA to fold into a catalytic conformation and act as an enzyme. The design of the aptasensor includes magnetic nanoparticles (MNPs), complementary DNA (cDNA) modified with biotin, and a label-free single strand DNA (ssDNA) including the aptamer and trivalent peroxidase-mimic DNAzyme. The trivalent DNAzyme, which has the highest catalytic activity among multivalent DNAzymes, catalyzed the H 2 O 2 -mediated oxidation of ABTS. The colorless ABTS was oxidized to produce a blue-green product that can be clearly distinguished by the naked eye. The aptamer and trivalent peroxidase-mimic DNAzyme promote the specificity and sensitivity of this detection method, which can be generalized for other targets by simply replacing the corresponding aptamers. To demonstrate the feasible use of the aptasensor for target detection, a well-known tumor biomarker MUC1 was evaluated as the model target. The limits of detection were determined to be 5.08 and 5.60 nM in a linear range of 50-1000 nM in a buffer solution and 10% serum system, respectively. This colorimetric and label-free aptasensor with excellent sensitivity and strong anti-interference ability has potential application in disease diagnoses, prognosis tracking, and therapeutic evaluation. Copyright © 2018 Elsevier B.V. All rights reserved.
Diagnostics of transparent polymer coatings of metal items
NASA Astrophysics Data System (ADS)
Varepo, L. G.; Ermakova, I. N.; Nagornova, I. V.; Kondratov, A. P.
2017-08-01
The methods of visual and instrumental express diagnostics of safety critical defects and non-uniform thickness of transparent mono- and multilayer polyolefin surface coating of metal items are analyzed in the paper. The instrumental diagnostics method relates to colorimetric measuring based on effects, which appear in the polarized light for extrusion polymer coatings. A color coordinates dependence (in the color system CIE La*b*) on both HDPE / PVC coating thickness fluctuation values (from average ones) and coating interlayer or adhesion layer delaminating is shown. A variation of color characteristics in the polarized light at a liquid penetration into delaminated polymer layers is found. Measuring parameters and critical uncertainties are defined.
Zhou, Zhide; Zhao, Le; Wang, Zhihong; Xue, Wen; Wang, Yunxiao; Huang, Yong; Liang, Jintao; Chen, Jiejing; Li, Guiyin
2018-06-01
Early diagnosis of diabetes yields significant clinical benefits. The serum level of 1,5‑anhydroglucitol (1,5‑AG) has been a new biochemical marker for postprandial hyperglycemia. In this study, a simple colorimetric method for 1,5‑AG detection has been designed based on highly efficient peroxidase mimetic activity of GQDs and enzyme-catalyzed reaction. By the catalytic action of pyranose oxidase (PROD), the 1,5‑AG was oxidized to 1,5‑anhydrofuctose and H 2 O 2 . The GQDs in the presence of H 2 O 2 exhibited highly efficient catalytic activity toward the oxidation of 3, 3', 5, 5'‑tetramethylbenzidine (TMB) to a blue colored product. The influence of relevant experimental variables was optimized. A linear relationship of optical signal with the concentration of 1,5‑AG in the range of 20.0-100.0μg/mL with the regression correlation coefficient of 0.9985 was obtained which could be monitored by colorimetry detection. The limit of detection (LOD) for 1,5‑AG detection was approximately 0.144μg/mL. All in all, the proposed 1,5‑AG detection system based on GQDs and PROD-catalyzed reaction showed better performances with simple operation, low-cost, higher selectivity. Copyright © 2018 Elsevier B.V. All rights reserved.
Reveko, Valeriia; Lampert, Felix; Din, Rameez U; Thyssen, Jacob P; Møller, Per
2018-05-01
A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. A colorimetric DPC spot test was used for the initial detection of hexavalent chromium on new and 1-year-aged trivalent chromium-passivated zinc surfaces. Then, X-ray photoelectron spectroscopy (XPS) was performed for all samples. The DPC spot test indicated the presence of hexavalent chromium in aged, but not new, trivalent chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent chromium-passivated zinc surface. Further validation of the use of the DPC test for chromium-containing metallic surfaces is required. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Improvement of the uric acid determination by the carbonate method for serum and urine
Eichhorn, F.; Zelmanowski, S.; Lew, E.; Rutenberg, A.; Fanias, B.
1961-01-01
An improved colorimetric procedure for determining uric acid by the carbonate method in serum and urine is described, using a 20% sodium carbonate solution with urea. Reliable results are also obtained in high concentrations of uric acid. PMID:13726059
Detection of influenza A virus subtypes using a solid-phase PCR microplate chip assay.
Sun, Xin-Cheng; Wang, YunLong; Yang, Liping; Zhang, HuiRu
2015-01-01
A rapid and sensitive microplate chip based on solid PCR was developed to identify influenza A subtypes. A simple ultraviolet cross-linking method was used to immobilize DNA probes on pretreated microplates. Solid-phase PCR was proven to be a convenient method for influenza A screening. The sensitivity of the microplate chip was 10(-3) μg/mL for the enzymatic colorimetric method and 10(-4) μg/mL for the fluorescence method. The 10 sets of primers and probes for the microplate chip were highly specific and did not interfere with each other. These results suggest that the microplate chip based on solid PCR can be used to rapidly detect universal influenza A and its subtypes. This platform can also be used to detect other pathogenic microorganisms. Copyright © 2014 Elsevier B.V. All rights reserved.
Suitability of analytical methods to measure solubility for the purpose of nanoregulation.
Tantra, Ratna; Bouwmeester, Hans; Bolea, Eduardo; Rey-Castro, Carlos; David, Calin A; Dogné, Jean-Michel; Jarman, John; Laborda, Francisco; Laloy, Julie; Robinson, Kenneth N; Undas, Anna K; van der Zande, Meike
2016-01-01
Solubility is an important physicochemical parameter in nanoregulation. If nanomaterial is completely soluble, then from a risk assessment point of view, its disposal can be treated much in the same way as "ordinary" chemicals, which will simplify testing and characterisation regimes. This review assesses potential techniques for the measurement of nanomaterial solubility and evaluates the performance against a set of analytical criteria (based on satisfying the requirements as governed by the cosmetic regulation as well as the need to quantify the concentration of free (hydrated) ions). Our findings show that no universal method exists. A complementary approach is thus recommended, to comprise an atomic spectrometry-based method in conjunction with an electrochemical (or colorimetric) method. This article shows that although some techniques are more commonly used than others, a huge research gap remains, related with the need to ensure data reliability.
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Schultz, John R.; Clarke, Mark S.
2007-01-01
Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.
Jasim, B; Jimtha John, C; Shimil, V; Jyothis, M; Radhakrishnan, E K
2014-09-01
The study mainly aimed quantitative analysis of IAA produced by endophytic bacteria under various conditions including the presence of extract from Piper nigrum. Analysis of genetic basis of IAA production was also conducted by studying the presence and diversity of the ipdc gene among the selected isolates. Five endophytic bacteria isolated previously from P. nigrum were used for the study. The effect of temperature, pH, agitation, tryptophan concentration and plant extract on modulating IAA production of selected isolates was analysed by colorimetric method. Comparative and quantitative analysis of IAA production by colorimetric isolates under optimal culture condition was analysed by HPTLC method. Presence of ipdc gene and thereby biosynthetic basis of IAA production among the selected isolates were studied by PCR-based amplification and subsequent insilico analysis of sequence obtained. Among the selected bacterial isolates from P. nigrum, isolate PnB 8 (Klebsiella pneumoniae) was found to have the maximum yield of IAA under various conditions optimized and was confirmed by colorimetric, HPLC and HPTLC analysis. Very interestingly, the study showed stimulating effect of phytochemicals from P. nigrum on IAA production by endophytic bacteria isolated from same plant. This study is unique because of the selection of endophytes from same source for comparative and quantitative analysis of IAA production under various conditions. Study on stimulatory effect of phytochemicals on bacterial IAA production as explained in the study is a novel approach. Studies on molecular basis of IAA production which was confirmed by sequence analysis of ipdc gene make the study scientifically attractive. Even though microbial production of IAA is well known, current report on detailed optimization, effect of plant extract and molecular confirmation of IAA biosynthesis is comparatively novel in its approach. © 2014 The Society for Applied Microbiology.
Development of a field method for measuring manganese in welding fume.
Dale Marcy, A; Drake, Pamela L
2007-11-01
Workers who perform routine welding tasks are potentially exposed to fume that may contain manganese. Manganese may cause respiratory problems and is implicated in causing the occurrence of Parkinson-like symptoms. In this study, a field colorimetric method for extracting and measuring manganese in welding fume was developed. The method uses ultrasonic extraction with an acidic hydrogen peroxide solution to extract welding fume collected on polyvinyl chloride filters. Commercially available pre-packaged reagents are used to produce a colored solution, created by a reaction of manganese(ii) with 1-(2-pyridylazo)-2-naphthol. Absorbance measurements are then made using a portable spectrophotometer. The method detection limit and limit of quantification (LOQ) were 5.2 microg filter(-1) and 17 microg filter(-1), respectively, with a dynamic range up to 400 microg filter(-1). When the results are above the LOQ for the colorimetric method, the manganese masses are equivalent to those measured by the International Organization for Standardization Method 15202-2, which employs a strong acid digestion and analysis using inductively coupled plasma-optical emission spectrometry.
Honeyfield, D.C.; Hanes, J.W.; Brown, L.; Kraft, C.E.; Begley, T.P.
2010-01-01
Thiaminase induced thiamine deficiency occurs in fish, humans, livestock and wild animals. A non-radioactive thiaminase assay was described in 2007, but a direct comparison with the radioactive 14C-thiamine method which has been in use for more than 30years has not been reported. The objective was to measure thiaminase activity in forage fish (alewife Alosa pseudoharengus, rainbow smelt Osmerus mordax, and slimy sculpin Cottus cognatus) consumed by predators that manifest thiamine deficiency using both methods. Modifications were made to the colorimetric assay to improve repeatability. Modification included a change in assay pH, enhanced sample clean-up, constant assay temperature (37??C), increase in the concentration of 4-nitrothiophenol (4NTP) and use of a spectrophotometer fitted with a 0.2cm cell. A strong relationship between the two assays was found for 51 alewife (R2=0.85), 36 smelt (R2=0.87) and 20 sculpin (R2=0.82). Thiaminase activity in the colorimetric assay was about 1000 times higher than activity measured by the radioactive method. Application of the assay to fish species from which no thiaminase activity has previously been reported resulted in no 4NTP thiaminase activity being found in bloater Coregonus hoyi, lake trout Salvelinus namaycusch, steelhead trout Oncorhynchus mykiss or Chinook salmon Oncorhynchus tshawytscha. In species previously reported to contain thiaminase, 4NTP thiaminase activity was measured in bacteria Paenibacillus thiaminolyticus, gizzard shad Dorosoma cepedianum, bracken fern Pteridium aquilinum, quagga mussel Dreissena bugensis and zebra mussels D. polymorpha. ?? 2010.
A novel fluoride ion colorimetric chemosensor based on coumarin.
Zhuang, Xiaoqing; Liu, Weimin; Wu, Jiasheng; Zhang, Hongyan; Wang, Pengfei
2011-09-01
A novel visible colorimetric sensor (L1) with high selectivity for fluoride ion based on coumarin has been synthesized by a simple modification of our earlier report. The chemosensor L1 shows an obvious color change from yellow to blue upon addition of fluoride ion with a large red shift of 145 nm in acetonitrile, and without interference of other anions such as Cl-, Br-, I-, NO3-, H2PO4-, HSO4-, and AcO-. The investigation of 1H NMR spectrum titration indicates the proposed mechanism is that F- first establishes a hydrogen bonding interaction with L1, and then the formation of [F-H-F]- induces deprotonation. Copyright © 2011 Elsevier B.V. All rights reserved.
Methods for the Measurement of a Bacterial Enzyme Activity in Cell Lysates and Extracts
Mendz, George; Hazell, Stuart
1998-01-01
The kinetic characteristics and regulation of aspartate carbamoyltransferase activity were studied in lysates and cell extracts of Helicobacter pylori by three diffirent methods. Nuclear magnetic resonance spectroscopy, radioactive tracer analysis, and spectrophotometry were employed in conjunction to identify the properties of the enzyme activity and to validate the results obtained with each assay. NMR spectroscopy was the most direct method to provide proof of ACTase activity; radioactive tracer analysis was the most sensitive technique and a microtitre-based colorimetric assay was the most cost-and time-efficient for large scale analyses. Freeze-thawing was adopted as the preferred method for cell lysis in studying enzyme activity in situ. This study showed the benefits of employing several different complementary methods to investigate bacterial enzyme activity. PMID:12734591
Rezaeian, Mohammad; Beakes, Gordon W; Parker, David S
2004-10-01
Anaerobic fungi were isolated from both the rumen and faeces of nine sheep and a cow. A reliable and simple method for the isolation of anaerobic fungi using 24 h rumen incubated milled straw as the inoculum source was developed. We also evaluate the use of chitin measurements as an assay of rumen fungal biomass. Chitin levels were determined from various sample sources (milled barley straw used as the fungal culture substrate in vitro; plant particulate digests from the rumen (PLP) and centrifuged strained rumen fluid (CSRF) using both HPLC and colorimetric methods. Both methods were highly correlated and consequently the simpler colorimetric method was adopted for subsequent studies. There was also a high degree of correlation between anaerobic fungal cellulase activities with the assayed chitin content of milled barley straw cultures over 12 d of an in vitro experiment. The colorimetric chitin assay protocol was then used to assess the diurnal variation and abundance of rumen fungi in in vivo assays. We assessed the distribution of chitin (mg g(-1) dry matter) in various fractions of the strained rumen fluid (SRF) and PLP samples from the rumen of sheep. Chitin was detected in all fractions of strained rumen fluid but the main source of chitin in the samples may be attributed to the fungal biomass. We did not detect any significant differences in chitin levels over a 24 h sampling period. Finally, an SEM study on subsamples of milled straw and plant particulate matter used in the chitin assays, revealed that the pattern of the fungal development on substrate material differs from the culture medium to the rumen.
Colorimetric detection of endogenous hydrogen sulfide production in living cells
NASA Astrophysics Data System (ADS)
Ahn, Yong Jin; Lee, Young Ju; Lee, Jaemyeon; Lee, Doyeon; Park, Hun-Kuk; Lee, Gi-Ja
2017-04-01
Hydrogen sulfide (H2S) has received great attention as a third gaseous signal transmitter, following nitric oxide and carbon monoxide. In particular, H2S plays an important role in the regulation of cancer cell biology. Therefore, the detection of endogenous H2S concentrations within biological systems can be helpful to understand the role of gasotransmitters in pathophysiology. Although a simple and inexpensive method for the detection of H2S has been developed, its direct and precise measurement in living cells remains a challenge. In this study, we introduced a simple, facile, and inexpensive colorimetric system for selective H2S detection in living cells using a silver-embedded Nafion/polyvinylpyrrolidone (PVP) membrane. This membrane could be easily applied onto a polystyrene microplate cover. First, we optimized the composition of the coating membrane, such as the PVP/Nafion mixing ratio and AgNO3 concentration, as well as the pH of the Na2S (H2S donor) solution and the reaction time. Next, the in vitro performance of a colorimetric detection assay utilizing the silver/Nafion/PVP membrane was evaluated utilizing a known concentration of Na2S standard solution both at room temperature and at 37 °C in a 5% CO2 incubator. As a result, the sensitivity of the colorimetric assay for H2S at 37 °C in the incubator (0.0056 Abs./μM Na2S, R2 = 0.9948) was similar to that at room temperature (0.0055 Abs./μM Na2S, R2 = 0.9967). Moreover, these assays were less sensitive to interference from compounds such as glutathione, L-cysteine (Cys), and dithiothreitol than to the H2S from Na2S. This assay based on the silver/Nafion/PVP membrane also showed excellent reproducibility (2.8% RSD). Finally, we successfully measured the endogenous H2S concentrations in live C6 glioma cells by s-(5‧-adenosyl)-L-methionine stimulation with and without Cys and L-homocysteine, utilizing the silver/Nafion/PVP membrane. In summary, colorimetric assays using silver/Nafion/PVP-coated membranes can be simple, robust, and reliable tools for the detection of H2S that can avoid the complicated and labor-intensive analytical approach used in conventional biology. In addition, we expect that this assay will demonstrate a powerful ability to study pathophysiological pathways that involve H2S.
Color accuracy and reproducibility in whole slide imaging scanners
Shrestha, Prarthana; Hulsken, Bas
2014-01-01
Abstract We propose a workflow for color reproduction in whole slide imaging (WSI) scanners, such that the colors in the scanned images match to the actual slide color and the inter-scanner variation is minimum. We describe a new method of preparation and verification of the color phantom slide, consisting of a standard IT8-target transmissive film, which is used in color calibrating and profiling the WSI scanner. We explore several International Color Consortium (ICC) compliant techniques in color calibration/profiling and rendering intents for translating the scanner specific colors to the standard display (sRGB) color space. Based on the quality of the color reproduction in histopathology slides, we propose the matrix-based calibration/profiling and absolute colorimetric rendering approach. The main advantage of the proposed workflow is that it is compliant to the ICC standard, applicable to color management systems in different platforms, and involves no external color measurement devices. We quantify color difference using the CIE-DeltaE2000 metric, where DeltaE values below 1 are considered imperceptible. Our evaluation on 14 phantom slides, manufactured according to the proposed method, shows an average inter-slide color difference below 1 DeltaE. The proposed workflow is implemented and evaluated in 35 WSI scanners developed at Philips, called the Ultra Fast Scanners (UFS). The color accuracy, measured as DeltaE between the scanner reproduced colors and the reference colorimetric values of the phantom patches, is improved on average to 3.5 DeltaE in calibrated scanners from 10 DeltaE in uncalibrated scanners. The average inter-scanner color difference is found to be 1.2 DeltaE. The improvement in color performance upon using the proposed method is apparent with the visual color quality of the tissue scans. PMID:26158041
Lee, HyungJae; Choi, Mihye; Hwang, Sang-Hyun; Cho, Youngnam
2018-01-01
Purpose: As human papillomavirus (HPV) is primarily responsible for the development of cervical cancer, significant efforts have been devoted to develop novel strategies for detecting and identifying HPV DNA in urine. The analysis of target DNA sequences in urine offers a potential alternative to conventional methods as a non-invasive clinical screening and diagnostic assessment tool for the detection of HPV. However, the lack of efficient approaches to isolate and directly detect HPV DNA in urine has restricted its potential clinical use. In this study, we demonstrated a novel approach of using polyethylenimine-conjugated magnetic polypyrrole nanowires (PEI-mPpy NWs) for the extraction, identification, and PCR-free colorimetric detection of high-risk strains of HPV DNA sequences, particularly HPV-16 and HPV-18, in urine specimens of cervical cancer patients. Materials and Methods: We fabricated and characterized polyethylenimine-conjugated magnetic nanowires (PEI/mPpy NWs). PEI/mPpy NWs-based HPV DNA isolation and detection strategy appears to be a cost-effective and practical technology with greater sensitivity and accuracy than other urine-based methods. Results: The analytical and clinical performance of PEI-mPpy NWs was evaluated and compared with those of cervical swabs, demonstrating a superior type-specific concordance rate of 100% between urine and cervical swabs, even when using a small volume of urine (300 µL). Conclusion: We envision that PEI-mPpy NWs provide substantive evidence for clinical diagnosis and management of HPV-associated disease with their excellent performance in the recovery and detection of HPV DNA from minimal amounts of urine samples. PMID:29290816
Assah, Enock; Goh, Walter; Zheng, Xin Ting; Lim, Ting Xiang; Li, Jun; Lane, David; Ghadessy, Farid; Tan, Yen Nee
2018-05-05
The tumor suppressor protein p53 plays a central role in preventing cancer through interaction with DNA response elements (REs) to regulate target gene expression in cells. Due to its significance in cancer biology, relentless efforts have been directed toward understanding p53-DNA interactions for the development of cancer therapeutics and diagnostics. In this paper, we report a rapid, label-free and versatile colorimetric assay to detect wildtype p53 DNA-binding function in complex solutions. The assay design is based on a concept that alters interparticle-distances between RE-AuNPs from a crosslinking effect induced through tetramerization of wildtype p53 protein (p53-WT) upon binding to canonical DNA motifs modified on gold nanoparticles (RE-AuNPs). This leads to a visible solution color change from red to blue, which is quantifiable by the UV- visible absorption spectra with a detection limit of 5 nM. Contrastingly, no color change was observed for the binding-deficient p53 mutants and non-specific proteins due to their inability to crosslink RE-AuNPs. Based on this sensing principle, we further demonstrate its utility for fast detection of drug-induced DNA binding function to cancer-associated Y220C mutant p53 protein using well-established reactivating compounds. By exploiting the dominant-negative property of mutant p53 over p53-WT and interactions with RE-AuNPs, this assay is configurable to detect low numbers of mutant p53 expressing cells in miniscule sample fractions obtained from typical core needle biopsy-sized tissues without signal attrition, alluding to the potential for biopsy sampling in cancer diagnostics or for defining cancer margins. This nanogold enabled colorimetric assay provides a facile yet robust method for studying important parameters influencing p53-DNA interactions with great promises for clinically pertinent applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Ultraviolet, Visible, and Fluorescence Spectroscopy
NASA Astrophysics Data System (ADS)
Penner, Michael H.
Spectroscopy in the ultraviolet-visible (UV-Vis) range is one of the most commonly encountered laboratory techniques in food analysis. Diverse examples, such as the quantification of macrocomponents (total carbohydrate by the phenol-sulfuric acid method), quantification of microcomponents, (thiamin by the thiochrome fluorometric procedure), estimates of rancidity (lipid oxidation status by the thiobarbituric acid test), and surveillance testing (enzyme-linked immunoassays), are presented in this text. In each of these cases, the analytical signal for which the assay is based is either the emission or absorption of radiation in the UV-Vis range. This signal may be inherent in the analyte, such as the absorbance of radiation in the visible range by pigments, or a result of a chemical reaction involving the analyte, such as the colorimetric copper-based Lowry method for the analysis of soluble protein.
NASA Astrophysics Data System (ADS)
Anekthirakun, Pimpimon; Sukwattanasinitt, Mongkol; Tuntulani, Thawatchai; Imyim, Apichat
2013-07-01
The colorimetric response (CR) of poly(10,12-pentacosadiynoic acid) vesicles (PPCDA) induced by α-cyclodextrin (α-CD) in an aqueous solution has been studied. Various parameters affecting the CR, such as response time and concentration were investigated. The blue color of 0.01 mM PPCDA solution became pinkish red with the addition of α-CD at the concentration higher than 3 mM. The inhibition of the color transition from blue to red was investigated using 11 phenolic compounds. The color transition could be inhibited and observed by naked eye in the presence of 4 phenolic compounds, i.e. 4-nitrophenol (4-NP) and 4-bromophenol (4-BP) and 4-chlorophenol (4-CP) and 3-nitrophenol (3-NP). A colorimetric method for the determination of these compounds was validated and applied for surface water analysis. The linear range from the plot of CR against phenolic compounds concentration was in the order of 0.5-2.0 mM with R2 more than 0.99. The recoveries were 90-95% with good precision (1-4%RSD, n = 10).
Efficient colorimetric pH sensor based on responsive polymer-quantum dot integrated graphene oxide.
Paek, Kwanyeol; Yang, Hyunseung; Lee, Junhyuk; Park, Junwoo; Kim, Bumjoon J
2014-03-25
In this paper, we report the development of a versatile platform for a highly efficient and stable graphene oxide (GO)-based optical sensor that exhibits distinctive ratiometric color responses. To demonstrate the applicability of the platform, we fabricated a colorimetric, GO-based pH sensor that responds to a wide range of pH changes. Our sensing system is based on responsive polymer and quantum dot (QD) hybrids integrated on a single GO sheet (MQD-GO), with the GO providing an excellent signal-to-noise ratio and high dispersion stability in water. The photoluminescence emissions of the blue and orange color-emitting QDs (BQDs and OQDs) in MQD-GO can be controlled independently by different pH-responsive linkers of poly(acrylic acid) (PAA) (pKa=4.5) and poly(2-vinylpyridine) (P2VP) (pKa=3.0) that can tune the efficiencies of Förster resonance energy transfer from the BQDs to the GO and from the OQDs to the GO, respectively. As a result, the color of MQD-GO changes from orange to near-white to blue over a wide range of pH values. The detailed mechanism of the pH-dependent response of the MQD-GO sensor was elucidated by measurements of time-resolved fluorescence and dynamic light scattering. Furthermore, the MQD-GO sensor showed excellent reversibility and high dispersion stability in pure water, indicating that our system is an ideal platform for biological and environmental applications. Our colorimetric GO-based optical sensor can be expanded easily to various other multifunctional, GO-based sensors by using alternate stimuli-responsive polymers.
Trinder, P.; Harper, F. E.
1962-01-01
A colorimetric technique for the determination of carboxyhaemoglobin in blood is described. Carbon monoxide released from blood in a standard Conway unit reacts with palladous chloride/arsenomolybdate solution to produce a blue colour. Using 0·5 to 2 ml. of blood, the method will estimate carboxyhaemoglobin accurately at levels from 0·1% to 100% of total haemoglobin and in the presence of other abnormal pigments. A number of methods are available for the determination of carboxyhaemoglobin; none is accurate below a concentration of 1·5 g. carboxyhaemoglobin per 100 ml. but for most clinical purposes this is not important. For forensic purposes and occasionally in clinical use, an accurate determination of carboxyhaemoglobin below 750 mg. per 100 ml. may be required and no really satisfactory method is at present available. Some time ago when it was important to know whether a person who was found dead in a burning house had died before or after the fire had started, we became interested in developing a method which would determine accurately carboxyhaemoglobin at levels of 750 mg. per 100 ml. PMID:13922505
Automated method for study of drug metabolism
NASA Technical Reports Server (NTRS)
Furner, R. L.; Feller, D. D.
1973-01-01
Commercially available equipment can be modified to provide automated system for assaying drug metabolism by continuous flow-through. System includes steps and devices for mixing drug with enzyme and cofactor in the presence of pure oxygen, dialyzing resulting metabolite against buffer, and determining amount of metabolite by colorimetric method.
REDUCTION OF NITRATE THROUGH THE USE OF NITRATE REDUCTASE FOR THE SMARTCHEM AUTOANALYZER
The standard method for the determination of nitrate in drinking water, USEPA Method 353.2 Determination of Nitrate-Nitrite by Automated Colorimetry, employs cadmium as the reductant for the conversion of nitrate to nitrite. The nitrite is then analyzed colorimetrically by way ...
Rico-Yuste, Alberto; González-Vallejo, Victoria; Benito-Peña, Elena; de Las Casas Engel, Tomás; Orellana, Guillermo; Moreno-Bondi, María Cruz
2016-04-05
We have developed disposable color-changing polymeric films for quantification of furfural-a freshness indicator-in beer using a smartphone-based reader. The films are prepared by radical polymerization of 4-vinylaniline, as a furfural-sensitive indicator monomer, 2-hydroxymethyl methacrylate as a comonomer, and ethylene dimethyl methacrylate (EDMA) as a cross-linker. The sensing mechanism is based on the Stenhouse reaction in which aniline and furfural react in acidic media with the generation of a deep red cyanine derivative, absorbing at 537 nm, which is visible to the naked eye. The colorimetric response has been monitored using either a portable fiber-optic spectrophotometer or the built-in camera of a smartphone. Under the optimized conditions, a linear response to furfural in beer was obtained in the 39 to 500 μg L(-1) range, with a detection limit of 12 μg L(-1), thus improving the performance of other well-established colorimetric or chromatographic methods. The novel films are highly selective to furfural, and no cross-reactivity has been observed from other volatile compounds generated during beer aging. A smartphone application (app), developed for Android platforms, measures the RGB color coordinates of the sensing membranes after exposure to the analyte. Following data processing, the signals are converted into concentration values by preloaded calibration curves. The method has been applied to determination of furfural in pale lager beers with different storage times at room temperature. A linear correlation (r > 0.995) between the storage time and the furfural concentration in the samples has been confirmed; our results have been validated by HPLC with diode-array detection.
Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping
2014-01-01
As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an "elongate and capture" procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.
Yao, Yingyi; Guo, Weisheng; Zhang, Jian; Wu, Yudong; Fu, Weihua; Liu, Tingting; Wu, Xiaoli; Wang, Hanjie; Gong, Xiaoqun; Liang, Xing-Jie; Chang, Jin
2016-09-07
Ultrasensitive and quantitative fast screening of cancer biomarkers by immunochromatography test strip (ICTS) is still challenging in clinic. The gold nanoparticles (NPs) based ICTS with colorimetric readout enables a quick spectrum screening but suffers from nonquantitative performance; although ICTS with fluorescence readout (FICTS) allows quantitative detection, its sensitivity still deserves more efforts and attentions. In this work, by taking advantages of colorimetric ICTS and FICTS, we described a reverse fluorescence enhancement ICTS (rFICTS) with bimodal signal readout for ultrasensitive and quantitative fast screening of carcinoembryonic antigen (CEA). In the presence of target, gold NPs aggregation in T line induced colorimetric readout, allowing on-the-spot spectrum screening in 10 min by naked eye. Meanwhile, the reverse fluorescence enhancement signal enabled more accurately quantitative detection with better sensitivity (5.89 pg/mL for CEA), which is more than 2 orders of magnitude lower than that of the conventional FICTS. The accuracy and stability of the rFICTS were investigated with more than 100 clinical serum samples for large-scale screening. Furthermore, this rFICTS also realized postoperative monitoring by detecting CEA in a patient with colon cancer and comparing with CT imaging diagnosis. These results indicated this rFICTS is particularly suitable for point-of-care (POC) diagnostics in both resource-rich and resource-limited settings.
NASA Astrophysics Data System (ADS)
Ravikumar, Nakul; Rogalski, Melissa M.; Benza, Donny; Lake, Joshua; Urban, Matthew; Pelham, Hunter; Anker, Jeffrey N.; DesJardins, John D.
2017-03-01
An orthopaedic screw was designed with an optical tension-indicator to non-invasively quantify screw tension and monitor the load sharing between the bone and the implant. The screw both applies load to the bone, and measures this load by reporting the strain on the screw. The screw contains a colorimetric optical encoder that converts axial strain into colorimetric changes visible through the head of the screw, or luminescent spectral changes that are detected through tissue. Screws were tested under cyclic mechanical loading to mimic in-vivo conditions to verify the sensitivity, repeatability, and reproducibility of the sensor. In the absence to tissue, color was measured using a digital camera as a function of axial load on a stainless steel cannulated (hollow) orthopedic screw, modified by adding a passive colorimetric strain gauge through the central hole. The sensor was able to quantify clinically-relevant bone healing strains. The sensor exhibited good repeatability and reproducibility but also displayed hysteresis due to the internal mechanics of the screw. The strain indicator was also modified for measurement through tissue by replacing the reflective colorimetric sensor with a low-background X-ray excited optical luminescence signal. Luminescent spectra were acquired through 6 mm of chicken breast tissue. Overall, this research shows feasibility for a unique device which quantifies the strain on an orthopedic screw. Future research will involve reducing hysteresis by changing the mechanism of strain transduction in the screw, miniaturizing the luminescent strain gauge, monitoring bending as well as tension, using alternative luminescent spectral rulers based upon near infrared fluorescence or upconversion luminescence, and application to monitoring changes in pretension and load sharing during bone healing.
Sensitive paper-based analytical device for fast colorimetric detection of nitrite with smartphone.
Zhang, Xiu-Xiu; Song, Yi-Zhen; Fang, Fang; Wu, Zhi-Yong
2018-04-01
On-site rapid monitoring of nitrite as an assessment indicator of the environment, food, and physiological systems has drawn extensive attention. Here, electrokinetic stacking (ES) was combined with colorimetric reaction on a paper-based device (PAD) to achieve colorless nitrite detection with smartphone. In this paper, nitrite was stacked on the paper fluidic channel as a narrow band by electrokinetic stacking. Then, Griess reagent was introduced to visualize the stacking band. Under optimal conditions, the sensitivity of nitrite was 160-fold increased within 5 min. A linear response in the range of 0.075 to 1.0 μg mL -1 (R 2 = 0.99) and a limit of detection (LOD) of 73 ng mL -1 (0.86 μM) were obtained. The LOD was 10 times lower than the reported PAD, and close to that achieved by a desktop spectrophotometer. The applicability was demonstrated by nitrite detection from saliva and water with good selectivity, adding 100 times more concentrated co-ions. High recovery (91.0~108.7%) and reasonable intra-day and inter-day reproducibility (RSD < 9%) were obtained. This work shows that the sensitivity of colorless analyte detection-based colorimetric reaction can be effectively enhanced by integration of ES on a PAD. Graphical abstract Schematic of the experimental setups (left) and the corresponding images (right) of the actual portable device.
Gold nanoparticles based colorimetric nanodiagnostics for cancer and infectious diseases
NASA Astrophysics Data System (ADS)
Valentini, Paola; Persano, Stefano; Cecere, Paola; Sabella, Stefania; Pompa, Pier Paolo
2014-03-01
Traditional in vitro diagnostics requires specialized laboratories and costly instrumentation, both for the amplification of nucleic acid targets (usually achieved by PCR) and for the assay readout, often based on fluorescence. We are developing hybrid nanomaterials-based sensors for the rapid and low-cost diagnosis of various disease biomarkers, for applications in portable platforms for diagnostics at the point-of-care. To this aim, we exploited the size and distancedependent optical properties of gold nanoparticles (AuNPs) to achieve colorimetric detection. Moreover, in order to avoid the complexity of thermal cycles associated to traditional PCR, the design of our systems includes signal amplification schemes, achieved by the use of enzymes (nucleases, helicase) or DNAzymes. Focused on instrument-free and sensitive detection, we carefully combined the intrinsic sensitivity by multivalency of functionalized AuNPs with isothermal and non-stringent enzyme-aided reaction conditions, controlled AuNPs aggregates, universal reporters and magnetic microparticles, the latter used both as a substrate and as a means for the colorimetric detection. We obtained simple and robust assays for the sensitive (pM range or better) naked-eye detection of cancer or infectious diseases (HPV, HCV) biomarkers, requiring no instrumentation except for a simple heating plate. Finally, we are also developing non-medical applications of these bio-nanosensors, such as in the development of on-field rapid tests for the detection of pollutants and other food and water contaminants.
Sol-Gel Matrices For Direct Colorimetric Detection Of Analytes
Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey
2002-11-26
The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.
Sol-gel matrices for direct colorimetric detection of analytes
Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey
2000-01-01
The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.
Colorimetric carbon dioxide detector to determine accidental tracheal feeding tube placement.
Howes, Daniel W; Shelley, Eric S; Pickett, William
2005-04-01
To determine the accuracy of colorimetric CO2 detection compared to the reference standard two-step radiological confirmation of feeding tube position. A prospective study was conducted with patients presenting to a 21-bed medical-surgical intensive care unit. An adapter was developed using an endotracheal tube adapter to connect a colorimetric CO2 detector to a feeding tube in an airtight manner. In part I of the study a feeding tube connected to the colorimeter was inserted into the endotracheal tubes of ten ventilated patients to test the device's ability to detect tracheal placement. In part II patients undergoing feeding tube insertion had tube position confirmed with the colorimeter as well as the reference standard two-step x-ray. In phase I the colorimeter correctly identified tracheal placement in all ten patients. In phase II 93/100 procedures ultimately were eligible; the colorimeter had a sensitivity of 0.88 (95% confidence interval: 0.65-1.00) and specificity of 0.99 (0.97-1.00). The device missed one of the eight tracheal placements. Agreement between the colorimeter and two-step x-ray interpretations was excellent (Kappa 0.86; standard error 0.10). We describe a novel, convenient method to confirm esophageal feeding tube placement. The device is easily assembled and inexpensive, but should not be reused. Colorimetric determination of tracheal feeding tube placement with this device has excellent agreement with the reference standard two-step radiological technique.
A high throughput colorimetric assay of β-1,3-D-glucans by Congo red dye.
Semedo, Magda C; Karmali, Amin; Fonseca, Luís
2015-02-01
Mushroom strains contain complex nutritional biomolecules with a wide spectrum of therapeutic and prophylactic properties. Among these compounds, β-d-glucans play an important role in immuno-modulating and anti-tumor activities. The present work involves a novel colorimetric assay method for β-1,3-d-glucans with a triple helix tertiary structure by using Congo red. The specific interaction that occurs between Congo red and β-1,3-d-glucan was detected by bathochromic shift from 488 to 516 nm (>20 nm) in UV-Vis spectrophotometer. A micro- and high throughput method based on a 96-well microtiter plate was devised which presents several advantages over the published methods since it requires only 1.51 μg of polysaccharides in samples, greater sensitivity, speed, assay of many samples and very cheap. β-D-Glucans of several mushrooms (i.e., Coriolus versicolor, Ganoderma lucidum, Pleurotus ostreatus, Ganoderma carnosum, Hericium erinaceus, Lentinula edodes, Inonotus obliquus, Auricularia auricular, Polyporus umbellatus, Cordyseps sinensis, Agaricus blazei, Poria cocos) were isolated by using a sequence of several extractions with cold and boiling water, acidic and alkaline conditions and quantified by this microtiter plate method. FTIR spectroscopy was used to study the structural features of β-1,3-D-glucans in these mushroom samples as well as the specific interaction of these polysaccharides with Congo red. The effect of NaOH on triple helix conformation of β-1,3-D-glucans was investigated in several mushroom species. Copyright © 2014 Elsevier B.V. All rights reserved.
Peng, Yanfen; Gelder, Victor Van; Amaladoss, Anburaj; Patel, Kadamb Haribhai
2016-10-21
This report presents two methods for the covalent immobilization of capture antibodies on cellulose filter paper grade No. 1 (medium-flow filter paper) discs and grade No. 113 (fast-flow filter paper) discs. These cellulose paper discs were grafted with amine functional groups through a silane coupling technique before the antibodies were immobilized on them. Periodate oxidation and glutaraldehyde cross-linking methods were used to graft capture antibodies on the cellulose paper discs. In order to ensure the maximum binding capacity of the capture antibodies to their targets after immobilization, the effects of various concentrations of sodium periodate, glutaraldehyde, and capture antibodies on the surface of the paper discs were investigated. The antibodies that were coated on the amine-functionalized cellulose paper discs through a glutaraldehyde cross-linking agent showed enhanced binding activity to the target when compared to the periodate oxidation method. IgG (in mouse reference serum) was used as a reference target in this study to test the application of covalently immobilized antibodies through glutaraldehyde. A new paper-based, enzyme-linked immunosorbent assay (ELISA) was successfully developed and validated for the detection of IgG. This method does not require equipment, and it can detect 100 ng/ml of IgG. The fast-flow filter paper was more sensitive than the medium-flow filter paper. The incubation period of this assay was short and required small sample volumes. This naked-eye, colorimetric immunoassay can be extended to detect other targets that are identified with conventional ELISA.
A new automated colorimetric method for measuring total oxidant status.
Erel, Ozcan
2005-12-01
To develop a new, colorimetric and automated method for measuring total oxidation status (TOS). The assay is based on the oxidation of ferrous ion to ferric ion in the presence of various oxidant species in acidic medium and the measurement of the ferric ion by xylenol orange. The oxidation reaction of the assay was enhanced and precipitation of proteins was prevented. In addition, autoxidation of ferrous ion present in the reagent was prevented during storage. The method was applied to an automated analyzer, which was calibrated with hydrogen peroxide and the analytical performance characteristics of the assay were determined. There were important correlations with hydrogen peroxide, tert-butyl hydroperoxide and cumene hydroperoxide solutions (r=0.99, P<0.001 for all). In addition, the new assay presented a typical sigmoidal reaction pattern in copper-induced lipoprotein autoxidation. The novel assay is linear up to 200 micromol H2O2 Equiv./L and its precision value is lower than 3%. The lower detection limit is 1.13 micromol H2O2 Equiv./L. The reagents are stable for at least 6 months on the automated analyzer. Serum TOS level was significantly higher in patients with osteoarthritis (21.23+/-3.11 micromol H2O2 Equiv./L) than in healthy subjects (14.19+/-3.16 micromol H2O2 Equiv./L, P<0.001) and the results showed a significant negative correlation with total antioxidant capacity (TAC) (r=-0.66 P<0.01). This easy, stable, reliable, sensitive, inexpensive and fully automated method that is described can be used to measure total oxidant status.
Lim, Min Yee; Huang, Jian; Zhao, Bai-xiao; Zou, Hui-qin; Yan, Yong-hong
2016-01-01
Moxibustion is an important traditional Chinese medicine therapy using heat from ignited moxa floss for disease treatment. The purpose of the present study is to establish a reproducible method to assess the color of moxa floss, discriminate the samples based on chromatic coordinates and explore the relationship between chromatic coordinates and total flavonoid content (TFC). Moxa floss samples of different storage years and production ratios were obtained from a moxa production factory in Henan Province, China. Chromatic coordinates (L*, a* and b*) were analyzed with an ultraviolet-visible spectrophotometer and the chroma (C*) and hue angle (h°) values were calculated. TFC was determined by a colorimetric method. Data were analyzed with correlation, principal component analysis (PCA). Significant differences in the chromatic values and TFC were observed among samples of different storage years and production ratios. Samples of higher production ratio displayed higher chromatic characteristics and lower TFC. Samples of longer storage years contained higher TFC. Preliminary separation of moxa floss production ratio was obtained by means of color feature maps developed using L*-a* or L*-b* as coordinates. PCA allowed the separation of the samples from their storage years and production ratios based on their chromatic characteristics and TFC. The use of a colorimetric technique and CIELAB coordinates coupled with chemometrics can be practical and objective for discriminating moxa floss of different storage years and production ratios. The development of color feature maps could be used as a model for classifying the color grading of moxa floss.
Sun, Xiaolong; Lacina, Karel; Ramsamy, Elena C; Flower, Stephen E; Fossey, John S; Qian, Xuhong; Anslyn, Eric V; Bull, Steven D; James, Tony D
2015-05-01
Using the self-assembly of aromatic boronic acids with Alizarin Red S (ARS), we developed a new chemosensor for the selective detection of peroxynitrite. Phenylboronic acid (PBA), benzoboroxole (BBA) and 2-( N , N -dimethylaminomethyl)phenylboronic acid (NBA) were employed to bind with ARS to form the complex probes. In particular, the ARS-NBA system with a high binding affinity can preferably react with peroxynitrite over hydrogen peroxide and other ROS/RNS due to the protection of the boron via the solvent-insertion B-N interaction. Our simple system produces a visible colorimetric change and on-off fluorescence response towards peroxynitrite. By coupling a chemical reaction that leads to an indicator displacement, we have developed a new sensing strategy, referred to herein as RIA (Reaction-based Indicator displacement Assay).
NASA Astrophysics Data System (ADS)
Dolai, Bholanath; Bhaumik, Atanu; Pramanik, Nabakumar; Ghosh, Kalyan Sundar; Atta, Ananta Kumar
2018-07-01
Naphthaldimine-based glucose derivatives 1 and 3 have been designed, synthesized and characterized. In aqueous media, glucose derivative 1, exhibited high selectivity and sensitivity towards Cu2+ ion in comparison with various cations and anions. In presence of Cu2+, sensor 1 has provided significant naked-eye detectable color change. The formation of 1-Cu2+ complex has been analyzed by UV-vis spectroscopy, 1H NMR titration experiments, mass spectrometry and DFT (density functional theory) calculations. Limit of detection of 1 as a colorimetric sensor for Cu2+ ion is found to be 0.23 μM, much lower than recommended value of World Health Organization (WHO), which makes to Cu2+ sensor 1 more effective and useful.
Ding, Yanan; Chen, Miaomiao; Wu, Kaili; Chen, Mingxing; Sun, Lifang; Liu, Zhenxue; Shi, Zhiqiang; Liu, Qingyun
2017-11-01
N,N'-di-caboxy methyl perylene diimides (PDI), as one of the most promising functional materials in optional chemosensing, was first used to combine with Co 3 O 4 nanoparticles through a facile two-step hydrothermal method and obtain the PDI functionalized Co 3 O 4 nanocomposites (PDI-Co 3 O 4 NCs). PDI-Co 3 O 4 NCs were characterized by a series of technical analysis including transmission electron microscope (TEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT-IR), respectively. The experimental results indicated that the as-prepared PDI-Co 3 O 4 NCs possessed the higher peroxidase-like activity than that of Co 3 O 4 nanoparticles without PDI, and could rapidly catalyze oxidation reaction of the chromogenic substrate TMB in the presence of H 2 O 2 to a blue product (oxTMB) observed by the naked eye. The improved catalytic activity of PDI-Co 3 O 4 NCs for colorimetric reactions could be attributed to the synergistic effects of PDI and Co 3 O 4 nanoparticles. On the basis of these experimental results, a convenient colorimetric system based on PDI-Co 3 O 4 as enzyme mimic that is highly sensitive and selective was developed for glucose detection. Meanwhile, the electron transfer between H 2 O 2 and TMB was responsible for the oxidation of TMB. The present work demonstrates a general strategy for the design of organic molecules functionalized oxide for different applications, such as nanocatalysts, biosensors and nanomedicine. Copyright © 2017 Elsevier B.V. All rights reserved.
Colorimetric analysis of pigmented skin lesions: a pilot study with the Visi-Chroma VC-100 device.
Vereecken, P; Mommaerts, M; Duez, C; Petein, M; Laporte, M; Hubinon, J-L; Heenen, M
2006-01-01
Definition of the colour of pigmented skin lesions (PSLs) with the naked eye remains subjective and may be influenced by lighting. This problem underlines the usefulness of instrumental assessments such as epiluminescence microscopy and colorimetric devices. We describe here a new method of colour analysis of PSLs with the Visi-Chroma VC-100 device, which illuminates the surface of the skin with white light-emitting diodes (LEDs) and analyses the reflected light by a red-green-blue (RGB) charge-coupled device (CCD) colour camera. Twenty-one PSLs to be excised for cosmetic or medical reasons were analysed by this device with clinicopathological correlation. This method is feasible and might be useful to assess the colour of PSLs and allow comparisons for changes over time. Further studies are needed to determine the usefulness of this device in clinical practice.
Ortiz-Gómez, Inmaculada; Salinas-Castillo, Alfonso; García, Amalia García; Álvarez-Bermejo, José Antonio; de Orbe-Payá, Ignacio; Rodríguez-Diéguez, Antonio; Capitán-Vallvey, Luis Fermín
2017-12-13
This work presents a microfluidic paper-based analytical device (μPAD) for glucose determination using a supported metal-organic framework (MOF) acting as a peroxidase mimic. The catalytic action of glucose oxidase (GOx) on glucose causes the formation of H 2 O 2 , and the MOF causes the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H 2 O 2 to form a blue-green product with an absorption peak at 650 nm in the detection zone. A digital camera and the iOS feature of a smartphone are used for the quantitation of glucose with the S coordinate of the HSV color space as the analytical parameter. Different factors such as the concentration of TMB, GOx and MOF, pH and buffer, sample volume, reaction time and reagent position in the μPAD were optimized. Under optimal conditions, the value for the S coordinate increases linearly up to 150 μmol·L -1 glucose concentrations, with a 2.5 μmol·L -1 detection limit. The μPAD remains stable for 21 days under conventional storage conditions. Such an enzyme mimetic-based assay to glucose determination using Fe-MIL-101 MOF implemented in a microfluidic paper-based device possesses advantages over enzyme-based assays in terms of costs, durability and stability compared to other existing glucose determination methods. The procedure was applied to the determination of glucose in (spiked) serum and urine. Graphical abstract Schematic representation of microfluidic paper-based analytical device using metal-organic framework as a peroxidase mimic for colorimetric glucose detection with digital camera or smartphone and iOS app readout.
NASA Astrophysics Data System (ADS)
Lan, Linxin; Li, Tianduo; Wei, Tao; Pang, He; Sun, Tao; Wang, Enhua; Liu, Haixia; Niu, Qingfen
2018-03-01
An oligothiophene-based colorimetric and ratiometric fluorescence dual-channel cyanide chemosensor 3 T-2CN was reported. Sensor 3 T-2CN showed both naked-eye recognition and ratiometric fluorescence response for CN- with an excellent selectivity and high sensitivity. The sensing mechanism based on the nucleophilic attack of CN- on the vinyl Cdbnd C bond has been successfully confirmed by the optical measurements, 1H NMR titration, FT-IR spectra as well as the DFT/TD-DFT calculations. Moreover, the detection limit was calculated to be 0.19 μM, which is much lower than the maximum permission concentration in drinking water (1.9 μM). Importantly, test strips (filter paper and TLC plates) containing 3 T-2CN were fabricated, which could act as a practical and efficient solid state optical sensor for CN- in field measurements.
Highly Sensitive and Fast Response Colorimetric Humidity Sensors Based on Graphene Oxides Film.
Chi, Hong; Liu, Yan Jun; Wang, FuKe; He, Chaobin
2015-09-16
Uniform graphene oxide (GO) film for optical humidity sensing was fabricated by dip-coating technique. The resulting GO thin film shows linear optical shifts in the visible range with increase of humidity in the whole relative humidity range (from dry state to 98%). Moreover, GO films exhibit ultrafast sensing to moisture within 250 ms because of the unique atomic thinness and superpermeability of GO sheets. The humidity sensing mechanism was investigated using XRD and computer simulation. The ultrasensitive humidity colorimetric properties of GOs film may enable many potential applications such as disposable humidity sensors for packaging, health, and environmental monitoring.
Ahn, Junho; Choi, Yeonweon; Lee, Ae-Ree; Lee, Joon-Hwa; Jung, Jong Hwa
2016-03-21
Using duplex DNA-AuNP aggregates, a sequence-specific DNA-binding protein, SQUAMOSA Promoter-binding-Like protein 12 (SPL-12), was directly determined by SPL-12-duplex DNA interaction-based colorimetric actions of DNA-Au assemblies. In order to prepare duplex DNA-Au aggregates, thiol-modified DNA 1 and DNA 2 were attached onto the surface of AuNPs, respectively, by the salt-aging method and then the DNA-attached AuNPs were mixed. Duplex-DNA-Au aggregates having the average size of 160 nm diameter and the maximum absorption at 529 nm were able to recognize SPL-12 and reached the equivalent state by the addition of ∼30 equivalents of SPL-12 accompanying a color change from red to blue with a red shift of the maximum absorption at 570 nm. As a result, the aggregation size grew to about 247 nm. Also, at higher temperatures of the mixture of duplex-DNA-Au aggregate solution and SPL-12, the equivalent state was reached rapidly. On the contrary, in the control experiment using Bovine Serum Albumin (BSA), no absorption band shift of duplex-DNA-Au aggregates was observed.
Colorimetric Aptasensor Based on Enzyme for the Detection of Vibrio parahemolyticus.
Wu, Shijia; Wang, Yinqiu; Duan, Nuo; Ma, Haile; Wang, Zhouping
2015-09-09
A simple colorimetric aptasensor system has been developed to detect Vibrio parahemolyticus. Magnetic nanoparticles (MNPs) are synthesized and conjugated with specific aptamers against target and used as capture probes. In addition, this method employs gold nanoparticles (AuNPs) as carriers of horseradish peroxidase (HRP) and aptamers, which served as signal probes. In the presence of target, a "sandwich-type" complex of AuNPs-HRP-aptamer-target-aptamer-MNPs is formed through specific recognition of aptamers and corresponding target. As a result, HRP molecules confined at the surface of the "sandwich" complexes catalyze the enzyme substrate, 3,3',5,5'-tetramethylbenzidine (TMB) and H2O2 and generate an optical signal. Under optimal conditions, the signals are linearly dependent on V. parahemolyticus concentrations from 10 to 10(6) colony-forming units (cfu)/mL in a logarithmic plot, with a limit of detection of 10 cfu/mL. Owing to AuNPs, a large amount of HRP could be loaded, resulting in an amplified signal, and the sensitivity would be improved. This strategy has the potential of being extended to the construction of simple monitor systems for a variety of biomolecules related to food safety.
NASA Astrophysics Data System (ADS)
Nopwinyuwong, Atchareeya; Kitaoka, Takuya; Boonsupthip, Waraporn; Pechyen, Chiravoot; Suppakul, Panuwat
2014-09-01
Polydiacetylene (PDA)/silica nanocomposites were synthesized by self-assembly method using polymerizable amphiphilic diacetylene monomers, 10,12-pentacosadiynoic acid (PCDA). Addition of cationic surfactants (PDADMAC and CTAB) to PDA/SiO2 nanocomposites induced higher intermolecular force which affected their size, shape and color transition. Pure PDA, PDA/SiO2, PDA/SiO2/PDADMAC and PDA/SiO2/CTAB were investigated by particle size analysis, TEM, SEM, UV-vis spectroscopy and FT-IR. It was found that the PDA/SiO2 nanocomposites exhibited slightly larger particle sizes than those of other samples. The PDA/SiO2 nanocomposites with a core-shell structure were almost regarded as spherical-shaped particles. Cationic surfactants, especially CTAB, presumably affected the particle size and shape of PDA/SiO2 nanocomposites due to the disruption of hydrogen bonding between PDA head group and ammonium group. The colorimetric response of both PDA/SiO2/surfactant and surfactant-free PDA/SiO2 aqueous solutions directly changed in relation to time and temperature; thus they were expected to be applied as a new polymer-based time-temperature indicator (TTI).
Houk, Ronald J. T.; Wallace, Karl J.; Hewage, Himali S.; Anslyn, Eric V.
2008-01-01
A colorimetric chemodosimeter (SQ1) for the detection of trace palladium salts in cross-coupling reactions mediated by palladium is described. Decolorization of SQ1 is affected by nucleophilic attack of ethanethiol in basic DMSO solutions. Thiol addition is determined to have an equilibrium constant (Keq) of 2.9 × 106 M-1, with a large entropic and modest enthalpic driving force. This unusual result is attributed to solvent effects arising from a strong coordinative interaction between DMSO and the parent squaraine. Palladium detection is achieved through thiol scavenging from the SQ1-ethanethiol complex leading to a color “turn-on” of the parent squaraine. It was found that untreated samples obtained directly from Suzuki couplings showed no response to the assay. However, treatment of the samples with aqueous nitric acid generates a uniform Pd(NO3)2 species, which gives an appropriate response. “Naked-eye” detection of Pd(NO3)2 was estimated to be as low as 0.5 ppm in solution, and instrument-based detection was tested as low as 100 ppb. The average error over the working range of the assay was determined to be 7%. PMID:19122841
Jiang, Chao; Yuan, Yuan; Yang, Guang; Jin, Yan; Liu, Libing; Zhao, Yuyang; Huang, Luqi
2016-10-21
Inaccurate labeling of materials used in herbal products may compromise the therapeutic efficacy and may pose a threat to medicinal safety. In this paper, a rapid (within 3 h), sensitive and visual colorimetric method for identifying substitutions in terminal market products was developed using cationic conjugated polymer-based fluorescence resonance energy transfer (CCP-based FRET). Chinese medicinal materials with similar morphology and chemical composition were clearly distinguished by the single-nucleotide polymorphism (SNP) genotyping method. Assays using CCP-based FRET technology showed a high frequency of adulterants in Lu-Rong (52.83%) and Chuan-Bei-Mu (67.8%) decoction pieces, and patented Chinese drugs (71.4%, 5/7) containing Chuan-Bei-Mu ingredients were detected in the terminal herbal market. In comparison with DNA sequencing, this protocol simplifies procedures by eliminating the cumbersome workups and sophisticated instruments, and only a trace amount of DNA is required. The CCP-based method is particularly attractive because it can detect adulterants in admixture samples with high sensitivity. Therefore, the CCP-based detection system shows great potential for routine terminal market checks and drug safety controls.
Jarujamrus, Purim; Meelapsom, Rattapol; Pencharee, Somkid; Obma, Apinya; Amatatongchai, Maliwan; Ditcharoen, Nadh; Chairam, Sanoe; Tamuang, Suparb
2018-01-01
A smartphone application, called CAnal, was developed as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury(II) in water samples. Measurement on the double layer of a microfluidic paper-based analytical device (μPAD) fabricated by alkyl ketene dimer (AKD)-inkjet printing technique with special design doped with unmodified silver nanoparticles (AgNPs) onto the detection zones was performed by monitoring the gray intensity in the blue channel of AgNPs, which disintegrated when exposed to mercury(II) on μPAD. Under the optimized conditions, the developed approach showed high sensitivity, low limit of detection (0.003 mg L -1 , 3SD blank/slope of the calibration curve), small sample volume uptake (two times of 2 μL), and short analysis time. The linearity range of this technique ranged from 0.01 to 10 mg L -1 (r 2 = 0.993). Furthermore, practical analysis of various water samples was also demonstrated to have acceptable performance that was in agreement with the data from cold vapor atomic absorption spectrophotometry (CV-AAS), a conventional method. The proposed technique allows for a rapid, simple (instant report of the final mercury(II) concentration in water samples via smartphone display), sensitive, selective, and on-site analysis with high sample throughput (48 samples h -1 , n = 3) of trace mercury(II) in water samples, which is suitable for end users who are unskilled in analyzing mercury(II) in water samples.
This method provides a procedure for the determination of dissolved silicate concentration in estuarine and coastal waters. The dissolved silicate is mainly in the form of silicic acid, H SiO , in estuarine and 4 4 coastal waters. All soluble silicate, including colloidal silici...
ERIC Educational Resources Information Center
Myers, Alan
1990-01-01
A method of obtaining a crude mitochondrial extract from sheep and beef heart is described. The respiratory substrates succinate and malate are examined as well as the inhibitory effect of malonate. An interface with a microcomputer for plotting colorimeter results is discussed. (Author/CW)
Jittangprasert, Piyada; Wilairat, Prapin; Pootrakul, Pensri
2004-12-01
This paper describes a comparison of two analytical techniques, one employing bathophenanthrolinedisulfonate (BPT), a most commonly-used reagent for Fe (II) determination, as chromogen and an electrothermal atomic absorption spectroscopy (ETAAS) for the quantification of non-transferrin bound iron (NTBI) in sera from thalassemic patients. Nitrilotriacetic acid (NTA) was employed as the ligand for binding iron from low molecular weight iron complexes present in the serum but without removing iron from the transferrin protein. After ultrafiltration the Fe (III)-NTA complex was then quantified by both methods. Kinetic study of the rate of the Fe (II)-BPT complex formation for various excess amounts of NTA ligand was also carried out. The kinetic data show that a minimum time duration (> 60 minutes) is necessary for complete complex formation when large excess of NTA is used. Calibration curves given by colorimetric and ETAAS methods were linear over the range of 0.15-20 microM iron (III). The colorimetric and ETAAS methods exhibited detection limit (3sigma) of 0.13 and 0.14 microM, respectively. The NTBI concentrations from 55 thalassemic serum samples measured employing BPT as chromogen were statistically compared with the results determined by ETAAS. No significant disagreement at 95% confidence level was observed. It is, therefore, possible to select any one of these two techniques for determination of NTBI in serum samples of thalassemic patients. However, the colorimetric procedure requires a longer analysis time because of a slow rate of exchange of NTA ligand with BPT, leading to the slow rate of formation of the colored complex.
Kim, Min Soon; Rodney, William N.; Cooper, Tara; Kite, Chris; Reece, Gregory P.; Markey, Mia K.
2011-01-01
Rationale, aims and objectives Scarring is a significant cause of dissatisfaction for women who undergo breast surgery. Scar tissue may be clinically distinguished from normal skin by aberrant color, rough surface texture, increased thickness (hypertrophy), and firmness. Colorimeters or spectrophotometers can be used to quantitatively assess scar color, but they require direct patient interaction and can cost thousands of dollars By comparison, digital photography is already in widespread use to document clinical outcomes and requires less patient interaction. Thus, assessment of scar coloration by digital photography is an attractive alternative. The goal of this study was to compare color measurements obtained by digital photography and colorimetry. Method Agreement between photographic and colorimetric measurements of color were evaluated. Experimental conditions were controlled by performing measurements on artificial scars created by a makeup artist. The colorimetric measurements of the artificial scars were compared to those reported in the literature for real scars in order to confirm the validity of this approach. We assessed the agreement between the colorimetric and photographic measurements of color using a hypothesis test for equivalence, the intra-class correlation coefficient (ICC), and the Bland-Altman method. Results Overall, good agreement was obtained for three parameters (L*a*b*) measured by colorimetry and photography from the results of three statistical analyses. Conclusion Color measurements obtained by digital photography were equivalent to those obtained using colorimetry. Thus, digital photography is a reliable, cost-effective measurement method of skin color and should be further investigated for quantitative analysis of surgical outcomes. PMID:19239578
Xiao, Liangpin; Liu, Xianming; Zhong, Runtao; Zhang, Kaiqing; Zhang, Xiaodi; Zhou, Xiaomian; Lin, Bingcheng; Du, Yuguang
2013-11-01
Three-dimensional (3D) paper-based microfluidics, which is featured with high performance and speedy determination, promise to carry out multistep sample pretreatment and orderly chemical reaction, which have been used for medical diagnosis, cell culture, environment determination, and so on with broad market prospect. However, there are some drawbacks in the existing fabrication methods for 3D paper-based microfluidics, such as, cumbersome and time-consuming device assembly; expensive and difficult process for manufacture; contamination caused by organic reagents from their fabrication process. Here, we present a simple printing-bookbinding method for mass fabricating 3D paper-based microfluidics. This approach involves two main steps: (i) wax-printing, (ii) bookbinding. We tested the delivery capability, diffusion rate, homogeneity and demonstrated the applicability of the device to chemical analysis by nitrite colorimetric assays. The described method is rapid (<30 s), cheap, easy to manipulate, and compatible with the flat stitching method that is common in a print house, making itself an ideal scheme for large-scale production of 3D paper-based microfluidics. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Label-free and pH-sensitive colorimetric materials for the sensing of urea
NASA Astrophysics Data System (ADS)
Li, Lu; Long, Yue; Gao, Jin-Ming; Song, Kai; Yang, Guoqiang
2016-02-01
This communication demonstrates a facile method for naked-eye detection of urea based on the structure color change of pH-sensitive photonic crystals. The insertion of urease provides excellent selectivity over other molecules. The detection of urea in different concentration ranges could be realized by changing the molar ratio between the functional monomer and cross-linker.This communication demonstrates a facile method for naked-eye detection of urea based on the structure color change of pH-sensitive photonic crystals. The insertion of urease provides excellent selectivity over other molecules. The detection of urea in different concentration ranges could be realized by changing the molar ratio between the functional monomer and cross-linker. Electronic supplementary information (ESI) available: Materials and chemicals, characterization, experimental details, and SEM images. See DOI: 10.1039/c5nr07690k
Della Pelle, Flavio; González, María Cristina; Sergi, Manuel; Del Carlo, Michele; Compagnone, Dario; Escarpa, Alberto
2015-07-07
In this work, a rapid and simple gold nanoparticle (AuNPs)-based colorimetric assay meets a new type of synthesis of AuNPs in organic medium requiring no sample extraction. The AuNPs synthesis extraction-free approach strategically involves the use of dimethyl sulfoxide (DMSO) acting as an organic solvent for simultaneous sample analyte solubilization and AuNPs stabilization. Moreover, DMSO works as a cryogenic protector avoiding solidification at the temperatures used to block the synthesis. In addition, the chemical function as AuNPs stabilizers of the sample endogenous fatty acids is also exploited, avoiding the use of common surfactant AuNPs stabilizers, which, in an organic/aqueous medium, rise to the formation of undesirable emulsions. This is controlled by adding a fat analyte free sample (sample blank). The method was exhaustively applied for the determination of total polyphenols in two selected kinds of fat-rich liquid and solid samples with high antioxidant activity and economic impact: olive oil (n = 28) and chocolate (n = 16) samples. Fatty sample absorbance is easily followed by the absorption band of localized surface plasmon resonance (LSPR) at 540 nm and quantitation is refereed to gallic acid equivalents. A rigorous evaluation of the method was performed by comparison with the well and traditionally established Folin-Ciocalteu (FC) method, obtaining an excellent correlation for olive oil samples (R = 0.990, n = 28) and for chocolate samples (R = 0.905, n = 16). Additionally, it was also found that the proposed approach was selective (vs other endogenous sample tocopherols and pigments), fast (15-20 min), cheap and simple (does not require expensive/complex equipment), with a very limited amount of sample (30 μL) needed and a significant lower solvent consumption (250 μL in 500 μL total reaction volume) compared to classical methods.
Triple-helix molecular switch-based aptasensors and DNA sensors.
Bagheri, Elnaz; Abnous, Khalil; Alibolandi, Mona; Ramezani, Mohammad; Taghdisi, Seyed Mohammad
2018-07-15
Utilization of traditional analytical techniques is limited because they are generally time-consuming and require high consumption of reagents, complicated sample preparation and expensive equipment. Therefore, it is of great interest to achieve sensitive, rapid and simple detection methods. It is believed that nucleic acids assays, especially aptamers, are very important in modern life sciences for target detection and biological analysis. Aptamers and DNA-based sensors have been widely used for the design of various sensors owing to their unique features. In recent years, triple-helix molecular switch (THMS)-based aptasensors and DNA sensors have been broadly utilized for the detection and analysis of different targets. The THMS relies on the formation of DNA triplex via Watson-Crick and Hoogsteen base pairings under optimal conditions. This review focuses on recent progresses in the development and applications of electrochemical, colorimetric, fluorescence and SERS aptasensors and DNA sensors, which are based on THMS. Also, the advantages and drawbacks of these methods are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.
Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Carrizales, Stephanie M.; McCoy, J. Torin
2009-01-01
In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was developed by a team of scientists and engineers from NASA s Habitability and Environmental Factors Division in the Space Life Sciences Directorate at Johnson Space Center, the Wyle Integrated Science and Engineering Group in Houston, Texas, the University of Utah, and Iowa State University. The CWQMK was flown and deployed as a Station Development Test Objective (SDTO) experiment on ISS. The goal of the SDTO experiment was to evaluate the acceptability of CSPE technology for routine water quality monitoring on ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on ISS. The results obtained from the SDTO experiment are also reported and discussed in detail.
Succinic acid functionalized silver nanoparticles (Suc-Ag NPs) for colorimetric sensing of melamine
NASA Astrophysics Data System (ADS)
Rajar, Kausar; Sirajuddin; Balouch, Aamna; Bhanger, M. I.; Shah, Muhammad Tariq; Shaikh, Tayyaba; Siddiqui, Samia
2018-03-01
In this study, a quantitative colorimetric sensing strategy is developed for the rapid, sensitive and selective determination of melamine. The sensing system relies on the application of succinic acid as a selective recognition probe functionalized over Ag NPs. The synthesized Ag NPs were modified with cysteamine to induce positively charged atmosphere which allowed easy and favorable functionalization of succinic acid. The di-carboxyl nature of succinic acid enabled its binding to both cysteamine and melamine. The strong and favorable linkage between succinic acids carbonyl and amine moieties of melamine triggered aggregation of silver NPs producing a significant shift in the measured absorption excitation. This change in the excitation along with the colorimetric response was found linearly proportional to the melamine concentration in the range of 0.1-1.2 μM. The developed sensor system is simple and unlike electrostatic attraction based sensor system utilize selective linkage for the recognition of melamine. In addition to this, the developed optical probe can efficiently be used for the determination of melamine in milk samples.
Zero- and two-dimensional hybrid carbon phosphors for high colorimetric purity white light-emission.
Ding, Yamei; Chang, Qing; Xiu, Fei; Chen, Yingying; Liu, Zhengdong; Ban, Chaoyi; Cheng, Shuai; Liu, Juqing; Huang, Wei
2018-03-01
Carbon nanomaterials are promising phosphors for white light emission. A facile single-step synthesis method has been developed to prepare zero- and two-dimensional hybrid carbon phosphors for the first time. Zero-dimensional carbon dots (C-dots) emit bright blue luminescence under 365 nm UV light and two-dimensional nanoplates improve the dispersity and film forming ability of C-dots. As a proof-of-concept application, the as-prepared hybrid carbon phosphors emit bright white luminescence in the solid state, and the phosphor-coated blue LEDs exhibit high colorimetric purity white light-emission with a color coordinate of (0.3308, 0.3312), potentially enabling the successful application of white emitting phosphors in the LED field.
Colorimetric assay for urinary track infection disease diagnostic on flexible substrate
NASA Astrophysics Data System (ADS)
Safavieh, Mohammadali; Ahmed, Minhaz Uddin; Zourob, Mohammed
2012-10-01
We are presenting cassette as a novel point of care diagnostic device. This device is easy to use, low cost to prepare, high throughput and can analyze several samples at the same time. We first, demonstrate the preparation method of the device. Then, fabrication of the flexible substrate has been presented. The device has been used for detection of the real sample of E.coli bacteria following by colorimetric detection. We have shown that we could detect 30 cfu/ml bacteria and 100 fg/μl of Staphylococous aureus DNA in 1 hr using LAMP amplification technique. This device will be helpful in hospitals and doctor's office for analysis of several patients' samples at the same time.
Colorimetric Characterization of Mobile Devices for Vision Applications.
de Fez, Dolores; Luque, Maria José; García-Domene, Maria Carmen; Camps, Vicente; Piñero, David
2016-01-01
Available applications for vision testing in mobile devices usually do not include detailed setup instructions, sacrificing rigor to obtain portability and ease of use. In particular, colorimetric characterization processes are generally obviated. We show that different mobile devices differ also in colorimetric profile and that those differences limit the range of applications for which they are most adequate. The color reproduction characteristics of four mobile devices, two smartphones (Samsung Galaxy S4, iPhone 4s) and two tablets (Samsung Galaxy Tab 3, iPad 4), have been evaluated using two procedures: 3D LUT (Look Up Table) and a linear model assuming primary constancy and independence of the channels. The color reproduction errors have been computed with the CIEDE2000 color difference formula. There is good constancy of primaries but large deviations of additivity. The 3D LUT characterization yields smaller reproduction errors and dispersions for the Tab 3 and iPhone 4 devices, but for the iPad 4 and S4, both models are equally good. The smallest reproduction errors occur with both Apple devices, although the iPad 4 has the highest number of outliers of all devices with both colorimetric characterizations. Even though there is good constancy of primaries, the large deviations of additivity exhibited by the devices and the larger reproduction errors make any characterization based on channel independence not recommendable. The smartphone screens show, in average, the best color reproduction performance, particularly the iPhone 4, and therefore, they are more adequate for applications requiring precise color reproduction.
Kolusheva, S; Yossef, R; Kugel, A; Katz, M; Volinsky, R; Welt, M; Hadad, U; Drory, V; Kliger, M; Rubin, E; Porgador, A; Jelinek, R
2012-07-17
We demonstrate a novel array-based diagnostic platform comprising lipid/polydiacetylene (PDA) vesicles embedded within a transparent silica-gel matrix. The diagnostic scheme is based upon the unique chromatic properties of PDA, which undergoes blue-red transformations induced by interactions with amphiphilic or membrane-active analytes. We show that constructing a gel matrix array hosting PDA vesicles with different lipid compositions and applying to blood plasma obtained from healthy individuals and from patients suffering from disease, respectively, allow distinguishing among the disease conditions through application of a simple machine-learning algorithm, using the colorimetric response of the lipid/PDA/gel matrix as the input. Importantly, the new colorimetric diagnostic approach does not require a priori knowledge on the exact metabolite compositions of the blood plasma, since the concept relies only on identifying statistically significant changes in overall disease-induced chromatic response. The chromatic lipid/PDA/gel array-based "fingerprinting" concept is generic, easy to apply, and could be implemented for varied diagnostic and screening applications.
Yoon, Bora; Park, In Sung; Shin, Hyora; Park, Hye Jin; Lee, Chan Woo; Kim, Jong-Man
2013-05-14
Inkjet-printed paper-based volatile organic compound (VOC) sensor strips imaged with polydiacetylenes (PDAs) are developed. A microemulsion ink containing bisurethane-substituted diacetylene (DA) monomers, 4BCMU, was inkjet printed onto paper using a conventional inkjet office printer. UV irradiation of the printed image allowed fabrication of blue-colored poly-4BCMU on the paper and the polymer was found to display colorimetric responses to VOCs. Interestingly, a blue-to-yellow color change was observed when the strip was exposed to chloroform vapor, which was accompanied by the generation of green fluorescence. The principal component analysis plot of the color and fluorescence images of the VOC-exposed polymers allowed a more precise discrimination of VOC vapors. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Multiplexed Colorimetric Solid-Phase Extraction
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.
2009-01-01
Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).
Francisco, Fabiane Lacerda; Saviano, Alessandro Morais; Pinto, Terezinha de Jesus Andreoli; Lourenço, Felipe Rebello
2014-08-01
Microbiological assays have been used to evaluate antimicrobial activity since the discovery of the first antibiotics. Despite their limitations, microbiological assays are widely employed to determine antibiotic potency of pharmaceutical dosage forms, since they provide a measure of biological activity. The aim of this work is to develop, optimize and validate a rapid colorimetric microplate bioassay for the potency of neomycin in pharmaceutical drug products. Factorial and response surface methodologies were used in the development and optimization of the choice of microorganism, culture medium composition, amount of inoculum, triphenyltetrazolium chloride (TTC) concentration and neomycin concentration. The optimized bioassay method was validated by the assessment of linearity (range 3.0 to 5.0μg/mL, r=0.998 and 0.994 for standard and sample curves, respectively), precision (relative standard deviation (RSD) of 2.8% and 4.0 for repeatability and intermediate precision, respectively), accuracy (mean recovery=100.2%) and robustness. Statistical analysis showed equivalency between agar diffusion microbiological assay and rapid colorimetric microplate bioassay. In addition, microplate bioassay had advantages concerning the sensitivity of response, time of incubation, and amount of culture medium and solutions required. Copyright © 2014 Elsevier B.V. All rights reserved.
Kim, Manuela; Stripeikis, Jorge; Iñón, Fernando; Tudino, Mabel
2007-05-15
A simple and sensitive HPLC post-derivatization method with colorimetric detection has been developed for the determination of N-nitroso glyphosate in samples of technical glyphosate. Separation of the analyte was accomplished using an anionic exchange resin (2.50mmx4.00mm i.d., 15mum particle size, functional group: quaternary ammonium salt) with Na(2)SO(4) 0.0075M (pH 11.5) (flow rate: 1.0mLmin(-1)) as mobile phase. After separation, the eluate was derivatized with a colorimetric reagent containing sulfanilamide 0.3% (w/v), [N-(1-naphtil)ethilendiamine] 0.03% (w/v) and HCl 4.5M in a thermostatized bath at 95 degrees C. Detection was performed at 546nm. All stages of the analytical procedure were optimized taking into account the concept of analytical minimalism: less operation times and costs; lower sample, reagents and energy consumption and minimal waste. The limit of detection (k=3) calculated for 10 blank replicates was 0.04mgL(-1) (0.8mgkg(-1)) in the solid sample which is lower than the maximum tolerable accepted by the Food and Agriculture Organization of the United Nations.
Biothiols induced colour change of silver nanoparticles: A colorimetric sensing strategy
NASA Astrophysics Data System (ADS)
Thomas, Ambily; Sivasankaran, Unni; Kumar, Krishnapillai Girish
2018-01-01
A sensor for the detection and determination of bio-thiols (glutathione (GSH) and cysteamine (Cyste)) has been developed by integrating the distinguished distance related optical characteristics of silver nanoparticles with the simplicity of colorimetric technique. In presence of these analytes, shift in surface plasmon resonance (SPR) absorption of silver nanoparticles (AgNPs) with change in its colour was observed. Yellow coloured AgNPs solution becomes colourless in presence of GSH and changes to red in presence of Cyste. FTIR, TEM and DLS studies were used to confirm the mechanism. The difference in absorption of AgNPs in the absence and presence of GSH was found to vary linearly in the range 1.00 × 10- 5 M to 5.00 × 10- 7 M concentration range with limit of detection at 3.68 × 10- 7 M. The method can also be applied to quantify Cyste in the range 1.10 × 10- 6 M to 5.00 × 10- 8 M with limit of detection at 1.80 × 10- 8 M. The utility of the proposed colorimetric assay is validated by determination of GSH and Cyste in artificial blood serum.
76 FR 37796 - Notice of Availability of Government-Owned Inventions; Available for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... Aircraft Division, Business and Partnership Office, Office of Research and Technology Applications... October 26, 2010 U.S. Patent Application No. 7,839,304 B2: Method and System for Alerting Aircrew to... Application No. 12/868,772: Colorimetric Method for Detection of Biodiesel in Fuel, Navy Case No. PAX37, filed...
UltraColor: a new gamut-mapping strategy
NASA Astrophysics Data System (ADS)
Spaulding, Kevin E.; Ellson, Richard N.; Sullivan, James R.
1995-04-01
Many color calibration and enhancement strategies exist for digital systems. Typically, these approaches are optimized to work well with one class of images, but may produce unsatisfactory results for other types of images. For example, a colorimetric strategy may work well when printing photographic scenes, but may give inferior results for business graphic images because of device color gamut limitations. On the other hand, a color enhancement strategy that works well for business graphics images may distort the color reproduction of skintones and other important photographic colors. This paper describes a method for specifying different color mapping strategies in various regions of color space, while providing a mechanism for smooth transitions between the different regions. The method involves a two step process: (1) constraints are applied so some subset of the points in the input color space explicitly specifying the color mapping function; (2) the color mapping for the remainder of the color values is then determined using an interpolation algorithm that preserves continuity and smoothness. The interpolation algorithm that was developed is based on a computer graphics morphing technique. This method was used to develop the UltraColor gamut mapping strategy, which combines a colorimetric mapping for colors with low saturation levels, with a color enhancement technique for colors with high saturation levels. The result is a single color transformation that produces superior quality for all classes of imagery. UltraColor has been incorporated in several models of Kodak printers including the Kodak ColorEase PS and the Kodak XLS 8600 PS thermal dye sublimation printers.
Sharma, Rekha; Dhillon, Ankita; Kumar, Dinesh
2018-03-26
The present paper reports a facile and selective colorimetric method for the detection of potential environmental and health hazardous metal ions using green synthesized silver nanoparticles (AgNPs). Here the organic functional groups present in the plant extract (Mentha arvensis) are used as reductants and stabilizers in the synthesis of AgNPs. They also provide a suitable binding site to the (Al(III)) analyte in the detection mechanism. The leaf extract of Mentha arvensis was used to synthesize AgNPs at room-temperature and at 80 °C. The AgNPs synthesized at 80 °C exhibit excellent selective colorimetric detection of Al(III). The as-synthesized AgNPs have been characterized, and the synthesis, stabilization of NPs and detection mechanism has also been illustrated by using UV-vis, XPS, FTIR, TEM, EDX, SEM, AAS, and TGA analytical tools and techniques. The selectivity of detection probe was supported by the reaction between probe and metal ions followed first-order kinetics having the highest value of the regression coefficient (R 2 = 0.99) for Al(III) and the analysis of thermodynamic parameters. The prepared sensor showed a lower limit of detection (LOD) of 1 nM (S/N = 3.2) in real water samples. The proposed method can be successfully utilized for the detection of Al(III) from both drinking and real water samples at the nanomolar level.
Kim, Min Soon; Rodney, William N; Cooper, Tara; Kite, Chris; Reece, Gregory P; Markey, Mia K
2009-02-01
Scarring is a significant cause of dissatisfaction for women who undergo breast surgery. Scar tissue may be clinically distinguished from normal skin by aberrant colour, rough surface texture, increased thickness (hypertrophy) and firmness. Colorimeters or spectrophotometers can be used to quantitatively assess scar colour, but they require direct patient interaction and can cost thousands of dollars. By comparison, digital photography is already in widespread use to document clinical outcomes and requires less patient interaction. Thus, assessment of scar coloration by digital photography is an attractive alternative. The goal of this study was to compare colour measurements obtained by digital photography and colorimetry. Agreements between photographic and colorimetric measurements of colour were evaluated. Experimental conditions were controlled by performing measurements on artificial scars created by a make-up artist. The colorimetric measurements of the artificial scars were compared with those reported in the literature for real scars in order to confirm the validity of this approach. We assessed the agreement between the colorimetric and photographic measurements of colour using a hypothesis test for equivalence, the intraclass correlation coefficient and the Bland-Altman method. Overall, good agreement was obtained for three parameters (L*a*b*) measured by colorimetry and photography from the results of three statistical analyses. Colour measurements obtained by digital photography were equivalent to those obtained using colorimetry. Thus, digital photography is a reliable, cost-effective measurement method of skin colour and should be further investigated for quantitative analysis of surgical outcomes.
Suebsing, R; Kampeera, J; Tookdee, B; Withyachumnarnkul, B; Turner, W; Kiatpathomchai, W
2013-10-01
Streptococcus agalactiae and Strep. iniae are bacterial pathogens that cause streptococcosis in many fish species. An accelerated colorimetric loop-mediated isothermal amplification (LAMP) assay with pre-addition of calcein was established, and the transmission and detection of Strep. agalactiae and Strep. iniae in tilapia under natural aquatic environment were investigated. A positive reaction was observed by a colour change from orange to green through the naked eyes after completion at 63°C for 30 min with 10 times higher sensitivity than that of nested PCR assays and without cross-amplification with other fish bacterial pathogens. All sample types of Nile and red tilapia (broodstock, fertilized egg, fry) were Strep. agalactiae- and Strep. iniae positive by this new method, implying that they could be vertically transmitted. With its application for screening broodstock and fry before stocking and for monitoring fish health in grow-out ponds, the method would become very useful in fish farming industry. The application of colorimetric LAMP with pre-addition of calcein offers simple, rapid and sensitive technique with applicability for small field laboratories. This technique explored the possible vertical transmission mode of Strep. agalactiae and Strep. iniae under natural aquatic environment. It could be such preliminary data provided for the screening broodstock before breeding and/or the specific-pathogen-free production. © 2013 The Society for Applied Microbiology.
2018-01-01
Sodium dodecyl sulfate electrophoresis (SDS) is a protein separation technique widely used, for example, prior to immunoblotting. Samples are usually prepared in a buffer containing both high concentrations of reducers and high concentrations of SDS. This conjunction renders the samples incompatible with common protein assays. By chelating the SDS, cyclodextrins make the use of simple, dye-based colorimetric assays possible. In this paper, we describe the optimization of the assay, focussing on the cyclodextrin/SDS ratio and the use of commercial assay reagents. The adaptation of the assay to a microplate format and using other detergent-containing conventional extraction buffers is also described. PMID:29641569
Li, Jiling; Xu, Xiaoyong; Shao, Xusheng; Li, Zhong
2015-12-01
A novel semi-rigid latent chromophore E1, containing an amide subunit activated by an adjacent semi-rigid intramolecular hydrogen-bonding (IHB) unit, was designed for the detection of fluoride ion by the 'naked-eye' in CH3CN. Comparative studies on structural analogs (E2, E3, and E4) provided significant insight into the structural and functional role of the amide N-H and IHB segment in the selective recognition of fluoride ions. The deprotonation of the amide N-H followed by the enhancement of intramolecular charge transfer (ICT) induced the colorimetric detection of E1 for fluoride ion. Copyright © 2015 John Wiley & Sons, Ltd.
Tong, Ying; Jiao, Xiangyu; Yang, Hankun; Wen, Yongqiang; Su, Lei; Zhang, Xueji
2016-04-01
Herein we report for the first time fabrication of reverse bumpy ball (RBB)-type-nanoreactor-based flexible peroxidase-mimic membrane reactors (MRs). The RBB-type nanoreactors with gold nanoparticles embedded in the inner walls of carbon shells were loaded on nylon membranes through a facile filtration approach. The as-prepared flexible catalytic membrane was studied as a peroxidase-mimic MR. It was found that the obtained peroxidase-mimic MR could exhibit several advantages over natural enzymes, such as facile and good recyclability, long-term stability and easy storage. Moreover, the RBB NS-modified nylon MRs as a peroxidase mimic provide a useful colorimetric assay for H₂O₂.
NASA Astrophysics Data System (ADS)
Yang, Yutao; Zhou, Tingting; Bai, Bozan; Yin, Caixia; Xu, Wenzhi; Li, Wei
2018-05-01
Two mitochondria-targeted colorimetric and ratiometric fluorescent probes for SO2 derivatives were constructed based on the SO2 derivatives-triggered Michael addition reaction. The probes exhibit high specificity toward HSO3-/SO32- by interrupting their conjugation system resulting in a large ratiometric blue shift of 46-121 nm in their emission spectrum. The two well-resolved emission bands can ensure accurate detection of HSO3-. The detection limits were calculated to be 1.09 and 1.35 μM. Importantly, probe 1 and probe 2 were successfully used to fluorescence ratiometric imaging of endogenous HSO3- in BT-474 cells.
Paper-based tuberculosis diagnostic devices with colorimetric gold nanoparticles
NASA Astrophysics Data System (ADS)
Tsai, Tsung-Ting; Shen, Shu-Wei; Cheng, Chao-Min; Chen, Chien-Fu
2013-08-01
A colorimetric sensing strategy employing gold nanoparticles and a paper assay platform has been developed for tuberculosis diagnosis. Unmodified gold nanoparticles and single-stranded detection oligonucleotides are used to achieve rapid diagnosis without complicated and time-consuming thiolated or other surface-modified probe preparation processes. To eliminate the use of sophisticated equipment for data analysis, the color variance for multiple detection results was simultaneously collected and concentrated on cellulose paper with the data readout transmitted for cloud computing via a smartphone. The results show that the 2.6 nM tuberculosis mycobacterium target sequences extracted from patients can easily be detected, and the turnaround time after the human DNA is extracted from clinical samples was approximately 1 h.
Kapperud, G; Vardund, T; Skjerve, E; Hornes, E; Michaelsen, T E
1993-01-01
A two-step polymerase chain reaction (PCR) procedure with two nested pairs of primers specific for the yadA gene of Yersinia enterocolitica was developed. The PCR assay identified all common pathogenic serogroups (O:3, O:5,27, O:8, O:9, O:13, and O:21) from three continents and differentiated pathogenic Y. enterocolitica from Y. pseudotuberculosis and from a variety of nonpathogenic yersiniae representing 25 serogroups and four species. The performance of the method was evaluated with seeded food and water samples. We compared two procedures for sample preparation prior to PCR: one was based on immunomagnetic separation of the target bacteria from the sample, using magnetic particles coated with immunoglobulin antibodies to Y. enterocolitica serogroup O:3, and the other method consisted of a series of centrifugation steps combined with proteinase treatment. Regardless of the method used, the PCR assay was capable of detecting 10 to 30 CFU/g of meat in 10(6)-fold excess of indigenous bacteria. When the samples were enriched overnight in a nonselective medium, the sensitivity was increased to approximately 2 CFU/g, except for samples with an extremely high background flora (> 10(7) CFU/g). We compared gel electrophoretic detection of PCR products with a colorimetric detection method designated DIANA (detection of immobilized amplified nucleic acids), which enabled easy visualization of amplified fragments in a microtiter plate format with an optical density reader. DIANA and gel electrophoresis showed complete concordance in their discrimination between positive and negative samples. The combination of immunomagnetic separation, nested PCR, and DIANA makes possible the development of a fully automated analytic process which requires a minimum of laboratory manipulations. Images PMID:8215366
Qassem, M; Hickey, M; Kyriacou, P A
2016-08-01
Lithium preparations are considered the most reliable form of mood stabilizing medication for patients with Bipolar disorder. Nevertheless, lithium is a toxic element and its therapeutic range is extremely narrow, with levels of 0.61.0 mEq considered normal, whereas levels above 1.5 mEq are toxic. Thus unfortunately, many patients reach toxic levels that lead to unnecessary complications. It is believed that personal monitoring of blood lithium levels would benefit patients taking lithium medication. Therefore, our aim is to develop a personal lithium blood level analyzer for patients with bipolar mood disorder, and we report here our initial results of a colorimetric-based method used to test drop-volumes of human plasma that had been spiked with lithium. It was possible to validate results with standard flame photometry readings. Applying the Partial Least Squares (PLS) method on preprocessed spectra, therapeutic concentrations of lithium in a single drop can be predicted in a rapid manner, and furthermore, the calibration results were used to select effective wavelengths which were employed as inputs in Multiple Linear Regression (MLR). The simplified algorithms of this would prove useful when developing a personal lithium analyzer. Overall, both calibration methods gave high correlation and small error outputs with a R2= 0.99036 and RMSEC = 0.03778, and R2= 0.994148 and RMSEC= 0.0294404, for PLS and MLR methods, respectively. The results show that the spectrophotometric determination of blood lithium levels can be extended beyond laboratory applications and indicate the capability of this testing principle to be employed in a personal monitoring device. Future work will now focus on the technical development of a miniaturized system for measurement of lithium levels in blood with an acceptable level of accuracy and sensitivity.
Kwon, Jae-Sung; Kim, Kwang-Mahn; Kim, Kyoung-Nam
2014-10-01
The biocompatibility evaluation of nanomaterials is essential for their medical diagnostic and therapeutic usage, where a cytotoxicity test is the simplest form of biocompatibility evaluation. Three methods have been commonly used in previous studies for the cytotoxicity testing of nanomaterials: trypan blue exclusion, colorimetric assay using water soluble tetrazolium (WST), and imaging under a microscope following calcein AM/ethidium homodimer-1 staining. However, there has yet to be a study to compare each method. Therefore, in this study three methods were compared using the standard reference material of sodium lauryl sulfate (SLS). Each method of the cytotoxicity test was carried out using mouse fibroblasts of L-929 exposed to different concentrations of SLS. Compared to the gold standard trypan blue exclusion test, both colorimetric assay using water soluble tetrazolium (WST) and imaging under microscope with calcein AM/ethidium homodimer-1 staining showed results that were not statistically different. Also, each method exhibited various advantages and disadvantages, which included the need of equipment, time taken for the experiment, and provision of additional information such as cell morphology. Therefore, this study concludes that all three methods of cytotoxicity testing may be valid, though careful consideration will be needed when selecting tests with regard to time, finances, and the amount of information required by the researcher(s).
Xu, Lei; Shen, Xin; Li, Bingzhi; Zhu, Chunhong; Zhou, Xuemin
2017-08-08
Adenosine is an endogenous nucleotide pivotally involved in nucleic acid and energy metabolism. Its excessive existence may indicate tumorigenesis, typically lung cancer. Encouraged by its significance as the clinical biomarker, sensitive assay methods towards adenosine have been popularized, with high cost and tedious procedures as the inevitable defects. Herein, we report a label-free aptamer-based exonuclease III (Exo III) amplification colorimetric aptasensor for the highly sensitive and cost-effective detection of adenosine. The strategy employed two unlabeled hairpin DNA oligonucleotides (HP1 and HP2), where HP1 contained the aptamer towards adenosine and HP2 embedded the guanine-rich sequence (GRS). In the presence of adenosine, hairpin HP1 could form specific binding with adenosine and trigger the unfolding of HP1's hairpin structure. The resulting adenosine-HP1 complex could hybridize with HP2, generating the Exo III recognition site. After Exo III-assisted degradation, the GRS was released from HP2, and the adenosine-HP1 was released back to the solution to combine another HP2, inducing the cycling amplification. After multiple circulations, the released ample GRSs were induced to form G-quadruplex, further catalyzing the oxidation of TMB, yielding a color change which was finally mirrored in the absorbance change. On the contrary, the absence of adenosine failed to unfold HP1, remaining color unchanged eventually. Thanks to the amplification strategy, the limit of detection was lowered to 17 nM with a broad linear range from 50 nM to 6 μM. The proposed method was successfully applied to the detection of adenosine in biological samples and satisfying recoveries were acquired. Copyright © 2017 Elsevier B.V. All rights reserved.
Gauthier, David T.; Cartwright, Deborah D.; Densmore, Christine L.; Blazer, Vicki; Ottinger, Christopher A.
2003-01-01
In this study we present a method for the measurement of in vitro mitogenesis in fish leucocytes that is based on the incorporation of the thymidine analogue 5′-bromo-2′-deoxyuridine (BrdU) into the DNA of replicating cells, followed by ELISA-based detection. This technique, adapted from methods developed for mammalian cells, operates on a similar biological principle to 3H-thymidine incorporation, but circumvents the logistical and safety issues inherent with the radioactive label. Because it directly measures DNA proliferation, the assay has advantages over other colorimetric methods that may be strongly influenced by leucocyte metabolic status. Using BrdU incorporation followed by ELISA, we evaluate the responsiveness of rainbow trout (Oncorhynchus mykiss [Walbaum]) leucocytes to the mammalian T-cell mitogen Concanavalin A (Con A) as well as the differential response of white perch (Morone americana [Gmelin]) leucocytes to Con A and pokeweed mitogen. Specific considerations intrinsic to the assay system are discussed, including the implications of utilising enzyme-based detection.
Wang, Aicheng; Zhao, Huimin; Chen, Xiaochi; Tan, Bing; Zhang, Yaobin; Quan, Xie
2017-05-15
A sensitive, rapid and label-free colorimetric aptasensor for sulfadimethoxine (SDM) detection was developed based on the tunable peroxidase-like activity of graphene/nickel@palladium nanoparticle (Gr/Ni@Pd) hybrids. The addition of the SDM aptamer could inhibit the peroxidase-like catalytic activity of the hybrids. However, the target SDM and aptamer could be triggered tightly and recover the catalytic activity of the Gr/Ni@Pd hybrids. Due to the peroxidase-like catalytic activity, Gr/Ni@Pd could catalyze the decomposition of H 2 O 2 with releasing hydroxyl radicals which further oxidized reagent 3, 3', 5, 5'-Tetramethylbenzidine (TMB) to oxTMB accompanied with a colorless-to-blue color change. The original color change could be applied to obtain quantitative detection of SDM, due to the relationship between the concentration of the target and the color difference. As a result, this approach performed a linear response for SDM from 1 to 500 ng/mL with a limit detection of 0.7 ng/mL (S/N = 3) under the optimized conditions and realized the detection of SDM in spiked lake water samples. Therefore, this colorimetric aptasensor was an alternative assay for SDM detection in real water. Moreover, with its design principle, this work might be applied to detecting other small molecule by employing appropriate aptamer. Copyright © 2017 Elsevier Inc. All rights reserved.
Du, Yan; Li, Bingling; Guo, Shaojun; Zhou, Zhixue; Zhou, Ming; Wang, Erkang; Dong, Shaojun
2011-02-07
The appearance of the aptamer provides good recognition elements for small molecules, especially for drugs. In this work, by combining the advantages of magnetic nanoparticles (MNPs) with colorimetric drug detection using hemin-G-quadruplex complex as the sensing element, we report a simple and sensitive DNAzyme-based colorimetric sensor for cocaine detection in a 3,3,5,5-tetramethylbenzidine sulfate (TMB)-H(2)O(2) reaction system. The whole experimental processes are simplified. Cocaine aptamer fragments, SH-C2, are covalently labeled onto the amine-functionalized MNPs. When the target cocaine and another cocaine aptamer fragments (C1) grafted with G-riched strand AG4 (i.e. C1-AG4) are present simultaneously, the C2 layer on MNPs hybridizes partly with C1-AG4 to bind the cocaine. The C1-AG4 can be combinded with hemin to form DNAzyme which can effectively catalyze the H(2)O(2)-mediated oxidation of TMB, giving rise to a change in solution color. Importantly, using MNPs as the separation and amplification elements could effectively reduce the background signal and the interference from the real samples. A linear response from 0.1 μM to 20 μM is obtained for cocaine and a detection limit of 50 nM is achieved, which provides high sensitivity and selectivity to detect cocaine.
Palindromic Molecule Beacon-Based Cascade Amplification for Colorimetric Detection of Cancer Genes.
Shen, Zhi-Fa; Li, Feng; Jiang, Yi-Fan; Chen, Chang; Xu, Huo; Li, Cong-Cong; Yang, Zhe; Wu, Zai-Sheng
2018-03-06
A highly sensitive and selective colorimetric assay based on a multifunctional molecular beacon with palindromic tail (PMB) was proposed for the detection of target p53 gene. The PMB probe can serve as recognition element, primer, and polymerization template and contains a nicking site and a C-rich region complementary to a DNAzyme. In the presence of target DNA, the hairpin of PMB is opened, and the released palindromic tails intermolecularly hybridize with each other, triggering the autonomous polymerization/nicking/displacement cycles. Although only one type of probe is involved, the system can execute triple and continuous polymerization strand displacement amplifications, generating large amounts of G-quadruplex fragments. These G-rich fragments can bind to hemin and form the DNAzymes that possess the catalytic activity similar to horseradish peroxidase, catalyzing the oxidation of ABTS by H 2 O 2 and producing the colorimetric signal. Utilizing the newly proposed sensing system, target DNA can be detected down to 10 pM with a linear response range from 10 pM to 200 nM, and mutant target DNAs are able to be distinguished even by the naked eye. The desirable detection sensitivity, high specificity, and operation convenience without any separation step and chemical modification demonstrate that the palindromic molecular beacon holds the potential for detecting and monitoring a variety of nucleic acid-related biomarkers.
Zhang, Haijuan; Qi, Shengda; Dong, Yalei; Chen, Xiaojiao; Xu, Yinyin; Ma, Yanhua; Chen, Xingguo
2014-05-15
This paper describes a colorimetric approach to determine trace amounts of nitrite in water supplies, meat and dairy products using 1-butyl-3-methylimidazolium-modified methyl red ([BMIM]MR) as a colour reagent. The technique capitalises on the catalytic effect of nitrite on the oxidative degradation of [BMIM]MR by potassium bromate in acidic media. The absorbances were proportional to nitrite concentrations in the range of 8.70×10(-2) to 4.17 μM with a detection limit of 1.64×10(-2) μM. Compared with the method using methyl red as a colour reagent, 60 times improvement of sensitivity was obtained. Activation energy and the apparent rate constant for the catalytic reaction are 61.11 kJ mol(-1) and 1.18×10(4) s(-1), respectively. The proposed method was successfully applied for the analysis of nitrite in Yellow River water, chicken, and milk with recoveries ranging from 96% to 105%. Copyright © 2013 Elsevier Ltd. All rights reserved.
A SIMPLE COLORIMETRIC METHOD TO DETECT BIOLOGICAL EVIDENCE OF HUMAN EXPOSURE TO MICROCYSTINS
Toxic cyanobacteria are contaminants of surface waters worldwide. Microcystins are some of the most commonly detected toxins. Biological evidence of human exposure may be difficult to obtain due to limitations associated with cost, laboratory capacity, analytic support, and exp...
A plasmonic colorimetric strategy for visual miRNA detection based on hybridization chain reaction
NASA Astrophysics Data System (ADS)
Miao, Jie; Wang, Jingsheng; Guo, Jinyang; Gao, Huiguang; Han, Kun; Jiang, Chengmin; Miao, Peng
2016-08-01
In this work, a novel colorimetric strategy for miRNA analysis is proposed based on hybridization chain reaction (HCR)-mediated localized surface plasmon resonance (LSPR) variation of silver nanoparticles (AgNPs). miRNA in the sample to be tested is able to release HCR initiator from a solid interface to AgNPs colloid system by toehold exchange-mediated strand displacement, which then triggers the consumption of fuel strands with single-stranded tails for HCR. The final produced long nicked double-stranded DNA loses the ability to protect AgNPs from salt-induced aggregation. The stability variation of the colloid system can then be monitored by recording corresponding UV-vis spectrum and initial miRNA level is thus determined. This sensing system involves only four DNA strands which is quite simple. The practical utility is confirmed to be excellent by employing different biological samples.
Zhang, Yuping; Jiang, Shimei
2012-09-14
A new and easy-to-prepare gelator based on cyano-substituted amide (BPNIA) was designed and synthesized. BPNIA could form thermoreversible gel in DMSO-H(2)O (v/v, 9 : 1) and ultrasound-stimulated gel in DMSO. FT-IR, UV-vis and XRD spectra indicated that the gelator molecules self-assemble into a fibrous network resulting from the cooperation of intermolecular hydrogen bonding, π-π stacking and cyano interactions. BPNIA can act as a highly selective colorimetric sensor for fluoride in DMSO, overcoming the interference of H(2)PO(4)(-), AcO(-) and other halide anions. The deprotonation of the NH groups is responsible for the dramatic color change from colorless to yellow. Interestingly, the organogel of BPNIA could allow a two channel fluoride response by proton controlled reversible sol-gel transition and color changes.
Liu, Qing; Fei, Qiang; Fei, Yanqun; Fan, Qian; Shan, Hongyan; Feng, Guodong; Huan, Yanfu
2015-12-05
A novel isonicotic acid hydrazide Schiff base derivative N'-(3,5-di-tert-butyl-2-hydroxy-benzylidene) isonicotinohydrazide (DHIH) has been synthesized and developed as a high selective and sensitive colorimetric probe for Cu(2+) determination. Addition of Cu(2+) to the solution of DHIH resulted in a rapid color change from colorless to yellow together with an obvious new absorption band appeared at the range of 400-440 nm by forming a 1:1 complex. Experimental results indicated that the DHIH could provide absorption response to Cu(2+) with a linear dynamic range from 1.0×10(-5) to 1.0×10(-4)mol/L. The detection limit of Cu(2+) was 5.24×10(-7)mol/L with good tolerance of other metal ions. Copyright © 2015 Elsevier B.V. All rights reserved.
An aptamer-based paper microfluidic device for the colorimetric determination of cocaine.
Wang, Ling; Musile, Giacomo; McCord, Bruce R
2018-02-01
A method utilizing paper microfluidics coupled with gold nanoparticles and two anticocaine aptamers has been developed to detect seized cocaine samples. The ready-to-use format involves the use of a paper strip that produces a color change resulting from the salt-induced aggregation of gold nanoparticles producing a visible color change indicating the presence of the drug. This format is specific for the detection of cocaine. The visual LOD for the method was 2.5 μg and the camera based LOD was 2.36 μg. The operation of the device is easy and rapid, and does not require extensive training or instrumentation. All of the materials utilized in the device are safe and environmental friendly. This device should prove a useful tool for the screening of forensic samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A microsphere-based assay for mutation analysis of the biotinidase gene using dried blood spots
Lindau-Shepard, Barbara; Janik, David K.; Pass, Kenneth A.
2012-01-01
Biotinidase deficiency is an autosomal recessive syndrome caused by defects in the biotinidase gene, the product of which affects biotin metabolism. Newborn screening (NBS) for biotinidase deficiency can identify affected infants prior to onset of symptoms; biotin supplementation can resolve or prevent the clinical features. In NBS, dry blood spots (DBS) are usually tested for biotinidase enzyme activity by colorimetric analysis. By taking advantage of the multiplexing capabilities of the Luminex platform, we have developed a microsphere-based array genotyping method for the simultaneous detection of six disease causing mutations in the biotinidase gene, thereby permitting a second tier of molecular analysis. Genomic DNA was extracted from 3.2 mm DBS. Biotinidase gene sequences, containing the mutations of interest, were amplified by multiplexed polymerase chain reaction, followed by multiplexed allele-specific primer extension using universally tagged genotyping primers. The products were then hybridized to anti-tag carrying xTAG microspheres and detected on the Luminex platform. Genotypes were verified by sequencing. Genotyping results of 22 known biotinidase deficient samples by our xTAG biotinidase assay was in concordance with the results obtained from DNA sequencing, for all 6 mutations used in our panel. These results indicate that genotyping by an xTAG microsphere-based array is accurate, flexible, and can be adapted for high-throughput. Since NBS for biotinidase deficiency is by enzymatic assay, less than optimal quality of the DBS itself can compromise enzyme activity, while the DNA from these samples mostly remains unaffected. This assay warrants evaluation as a viable complement to the biotinidase semi-quantitative colorimetric assay. PMID:27625817
Sulfuric acid/hydrogen peroxide digestion and colorimetric a collaborative study.
Christians, D K; Aspelund, T G; Brayton, S V; Roberts, L L
1991-01-01
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.
MATRIX DISCRIMINANT ANALYSIS WITH APPLICATION TO COLORIMETRIC SENSOR ARRAY DATA
Suslick, Kenneth S.
2014-01-01
With the rapid development of nano-technology, a “colorimetric sensor array” (CSA) which is referred to as an optical electronic nose has been developed for the identification of toxicants. Unlike traditional sensors which rely on a single chemical interaction, CSA can measure multiple chemical interactions by using chemo-responsive dyes. The color changes of the chemo-responsive dyes are recorded before and after exposure to toxicants and serve as a template for classification. The color changes are digitalized in the form of a matrix with rows representing dye effects and columns representing the spectrum of colors. Thus, matrix-classification methods are highly desirable. In this article, we develop a novel classification method, matrix discriminant analysis (MDA), which is a generalization of linear discriminant analysis (LDA) for the data in matrix form. By incorporating the intrinsic matrix-structure of the data in discriminant analysis, the proposed method can improve CSA’s sensitivity and more importantly, specificity. A penalized MDA method, PMDA, is also introduced to further incorporate sparsity structure in discriminant function. Numerical studies suggest that the proposed MDA and PMDA methods outperform LDA and other competing discriminant methods for matrix predictors. The asymptotic consistency of MDA is also established. R code and data are available online as supplementary material. PMID:26783371
ERIC Educational Resources Information Center
Shaver, Lee Alan; Leung, Sam H.; Puderbaugh, Amy; Angel, Stephen A.
2011-01-01
The determination of total phenolics in foods and fruit juices was used successfully as a laboratory experiment in our undergraduate general, organic, and biological (GOB) chemistry course. Two different colorimetric methods were used over three years and comparative student results indicate that a ferrous ammonium sulfate (FAS) indicator…