Sample records for common atrial flutter

  1. [Typical atrial flutter: Diagnosis and therapy].

    PubMed

    Thomas, Dierk; Eckardt, Lars; Estner, Heidi L; Kuniss, Malte; Meyer, Christian; Neuberger, Hans-Ruprecht; Sommer, Philipp; Steven, Daniel; Voss, Frederik; Bonnemeier, Hendrik

    2016-03-01

    Typical, cavotricuspid-dependent atrial flutter is the most common atrial macroreentry tachycardia. The incidence of atrial flutter (typical and atypical forms) is age-dependent with 5/100,000 in patients less than 50 years and approximately 600/100,000 in subjects > 80 years of age. Concomitant heart failure or pulmonary disease further increases the risk of typical atrial flutter.Patients with atrial flutter may present with symptoms of palpitations, reduced exercise capacity, chest pain, or dyspnea. The risk of thromboembolism is probably similar to atrial fibrillation; therefore, the same antithrombotic prophylaxis is required in atrial flutter patients. Acutely symptomatic cases may be subjected to cardioversion or pharmacologic rate control to relieve symptoms. Catheter ablation of the cavotricuspid isthmus represents the primary choice in long-term therapy, associated with high procedural success (> 97 %) and low complication rates (0.5 %).This article represents the third part of a manuscript series designed to improve professional education in the field of cardiac electrophysiology. Mechanistic and clinical characteristics as well as management of isthmus-dependent atrial flutter are described in detail. Electrophysiological findings and catheter ablation of the arrhythmia are highlighted.

  2. Prospective evaluation of a simplified approach for common atrial flutter radio frequency ablation with only two catheters.

    PubMed

    Klug, D; Lacroix, D; Marquié, C; Mairesse, G; Alix, D; Dennetière, S; d'Hautefeuille, B; Zghal, N; Kacet, S

    2001-07-01

    Intra-atrial conduction block within the inferior vena cava-tricuspid annulus isthmus (IVCT) has been shown to predict successful common atrial flutter ablation. However, its demonstration requires the use of several electrode catheters and mapping of the line of block. The aim of this study was prospectively to test the feasibility of a simplified ablation procedure using only two catheters. Radio frequency (RF) ablation of common atrial flutter was performed in 30 patients with the sole use of a catheter for atrial pacing and a RF catheter. RF ablation lesions were created in the IVCT. Surface ECG criteria were used to monitor the conduction within the IVCT. The end point during low lateral atrial pacing was an increment in the interval between the pacing artefact and the peak of the R wave in surface lead II >50 ms and clockwise rotation of the P wave axis beyond -30 degrees and inferiorly. Then, the line of lesions was mapped during atrial pacing with the RF catheter. Additional RF lesions were applied if mapping disclosed a zone of residual conduction. Otherwise the procedure was stopped if mapping showed parallel double potentials all along the line. Finally, the block was reassessed with a 'Halo' catheter. Surface ECG criteria were met in 26 patients. Mapping the line of lesions showed a complete corridor of parallel double potentials in these 26 cases and in 3 of the 4 patients in whom ECG criteria were not met. Conduction evaluated with the Halo catheter showed bi-directional complete block in these 29 patients. After a follow-up of 16 +/- 4 months there was no recurrence of atrial flutter. Surface ECG criteria combined with mapping of the line of block demonstrate evidence of bi-directional IVCT block. This simplified RF ablation of common atrial flutter is feasible with a low recurrence rate.

  3. New antiarrhythmic agents for atrial fibrillation and atrial flutter: United States drug market response as an indicator of acceptance.

    PubMed

    LaPointe, Nancy M Allen; Pamer, Carol A; Kramer, Judith M

    2003-10-01

    To determine how well dofetilide and Betapace AF (sotalol, approved solely for atrial fibrillation and atrial flutter), with their detailed dosing and monitoring guidelines for safety, were accepted into clinical practice during the 2 calendar years after their introduction. We reviewed the number of new, refill, and total prescriptions of all antiarrhythmic agents in the United States from April 2000-December 2001 to assess use of dofetilide and Betapace AF in the drug market. Both were prescribed very infrequently throughout the study period. In addition, the infrequent reported use of these drugs for patients with atrial fibrillation and flutter indicated poor acceptance of these agents by prescribing physicians. We speculated that the restricted distribution and required educational program for dofetilide, as well as the availability of generic sotalol products, may have discouraged physicians from prescribing both dofetilide and Betapace AE CONCLUSION: A common goal for both the dofetilide risk-management program and the creation of a sotalol product indicated solely for atrial fibrillation and atrial flutter was to provide safer treatment for patients with these arrhythmias. Unfortunately, limited penetration of dofetilide and Betapace AF into the U.S. market suggests that drugs without a risk-management program or detailed dosing guidelines were more likely than dofetilide or Betapace AF to be selected for treatment of atrial fibrillation and atrial flutter.

  4. Coronary Sinus Activation and ECG Characteristics of Roof-Dependent Left Atrial Flutter After Pulmonary Vein Isolation.

    PubMed

    Casado Arroyo, Ruben; Laţcu, Decebal Gabriel; Maeda, Shingo; Kubala, Maciej; Santangeli, Pasquale; Garcia, Fermin Carlos; Enache, Bogdan; Eljamili, Mohammed; Hayashi, Tatsuya; Zado, Erica S; Saoudi, Nadir; Marchlinski, Francis E

    2018-06-01

    The electrocardiographic and intracardiac activation features of left atrial roof-dependent macroreentrant flutter have been incompletely characterized. Patients post-pulmonary vein (PV) isolation with roof-dependent atrial flutter based on activation and entrainment mapping were included. ECG and coronary sinus activation were compared with mitral annular (MA) flutter. The roof-dependent left atrial flutter circled the right PVs in 32 of 33 cases. Two forms of roof flutters were identified, posteroanterior, ascendant on posterior wall and descendant on anterior wall (n=24); and anteroposterior, ascendant on the anterior wall and descendent on the posterior wall (n=9). Both forms had positive large amplitude P waves in V 1 through V 2 with decreasing amplitude in V 3 through V 6 . Posteroanterior roof flutters had positive P wave in the inferior and negative P wave in leads I and aVL similar to counterclockwise MA flutter, but coronary sinus activation was simultaneous for roof and proximal to distal for counterclockwise. Anteroposterior roof flutters were similar to clockwise MA flutter with negative P in inferior leads and transition to flat or negative P in V 3 through V 6 . Coronary sinus activation time ≤39 ms identified roof versus MA flutter (sensitivity: 100% and specificity: 97%). Roof-dependent flutter around right PVs is more common than around left PVs. The ECG pattern for roof-dependent flutter around right PVs is similar to MA flutter with frontal plane axis dictated by septal activation. Roof-dependent flutter can be distinguished from MA flutter by more simultaneous rather than sequential coronary sinus activation. © 2018 American Heart Association, Inc.

  5. Risk of pacemaker implantation after uneventful successful cavotricuspid isthmus radiofrequency ablation in patients with common atrial flutter.

    PubMed

    Rodríguez-Mañero, Moisés; González-Melchor, Layla; Ballesteros, Gabriel; Raposeiras-Roubín, Sergio; García-Seara, Javier; López, Xesús Alberte Fernández; Cambeiro, Cristina González; Alcalde, Oscar; García-Bolao, Ignacio; Martínez-Sande, Luis; González-Juanatey, José Ramón

    2016-01-01

    Little is known about the risk of pacemaker implantation after common atrial flutter ablation in the long-term. We retrospectively reviewed the electrophysiology laboratory database at two Spanish University Hospitals from 1998 to 2012 to identify patients who had undergone successful ablation for cavotricuspid dependent atrial flutter. Cox regression analysis was used to examine the risk of pacemaker implantation. A total of 298 patients were considered eligible for inclusion. The mean age of the enrolled patients was 65.7±11. During 57.7±42.8 months, 30 patients (10.1%) underwent pacemaker implantation. In the stepwise multivariate models only heart rate at the time of the ablation (OR: 0.96; 95% CI: 0.93-0.98; p<0.0001) and intraventricular conduction disturbances in the baseline ECG (OR: 3.87; 95% CI: 1.54-9.70; p=0.004) were independents predictors of the need of pacemaker implantation. A heart rate of ≤65 bpm was identified as the optimal cut-off value to predict the need of pacemaker implantation in the follow-up (sensitivity: 79%, specificity: 74%) by ROC curve analyses. This is the first study of an association between the slow conducting common atrial flutter and subsequent risk of pacemaker implantation. In light of these findings, assessing it prior to ablation can be helpful for the risk stratification of sinus node disease or atrioventricular conduction disease requiring a pacemaker implantation in patients with persistent atrial flutter. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Electrophysiological determinant for induction of isthmus dependent counterclockwise and clockwise atrial flutter in humans.

    PubMed

    Lin, J L; Lai, L P; Lin, L J; Tseng, Y Z; Lien, W P; Huang, S K

    1999-01-01

    To investigate the electrophysiological determinant underlying the electrical induction of counterclockwise and clockwise isthmus dependent atrial flutter. The isthmus bordered by the inferior vena caval orifice-tricuspid annulus-coronary sinus ostium (IVCO-TA-CSO) has been assumed to be the site of both slow conduction and unidirectional block critical to the initiation of atrial flutter. Trans-isthmus and the global atrial conduction were studied in 25 patients with isthmus dependent atrial flutter (group A) and in 21 patients without atrial flutter (group B), by pacing at the coronary sinus ostium and the low lateral right atrium (LLRA) and mapping with a 20 pole Halo catheter in the right atrium. Mean (SD) fluoroscopic isthmus length between the coronary sinus ostium and LLRA sites was 28.1 (4.0) mm in group A and 28.0 (3.9) mm in group B (p = 0.95), but the trans-isthmus conduction velocity of both directions at various pacing cycle lengths was nearly halved in group A compared with group B (mean 0.39-0.46 m/s v 0.83-0.89 m/s, p < 0.0001). Pacing at coronary sinus ostium directly induced counterclockwise atrial flutter in 14 patients and pacing at LLRA induced clockwise atrial flutter in 11 patients, following abrupt unidirectional trans-isthmus block. Transient atrial tachyarrhythmias preceded the onset of atrial flutter in 10 counterclockwise and six clockwise cases of atrial flutter. None of the group B patients had inducible atrial flutter even in the presence of trans-isthmus block. The intra- and interatrial conduction times, as well as the conduction velocities at the right atrial free wall and the septum, were similar and largely within the normal range in both groups. Critical slowing of the trans-IVCO-TA-CSO isthmus conduction, but not the unidirectional block or the global atrial performance, is the electrophysiological determinant of the induction of counterclockwise and clockwise isthmus dependent atrial flutter in man.

  7. Myotonic Dystrophy Initially Presenting as Tachycardiomyopathy Successful Catheter Ablation of Atrial Flutter

    PubMed Central

    Asbach, S.; Gutleben, K. J.; Dahlem, P.; Brachmann, J.; Nölker, G.

    2010-01-01

    Myotonic dystrophy is a genetic muscular disease that is frequently associated with cardiac arrhythmias. Bradyarrhythmias, such as sinus bradycardia and atrioventricular block, are more common than tachyarrhythmias. Rarely, previously undiagnosed patients with myotonic dystrophy initially present with a tachyarrhythmia. We describe the case of a 14-year-old boy, who was admitted to the hospital with clinical signs and symptoms of decompensated heart failure and severely reduced left ventricular function. Electrocardiography showed common-type atrial flutter with 2 : 1 conduction resulting in a heart rate of 160 bpm. Initiation of medical therapy for heart failure as well as electrical cardioversion led to a marked clinical improvement. Catheter ablation of atrial flutter was performed to prevent future cardiac decompensations and to prevent development of tachymyopathy. Left ventricular function normalized during followup. Genetic analysis confirmed the clinical suspicion of myotonic dystrophy as known in other family members in this case. PMID:20871860

  8. Prospective Observational Cohort Study of Fetal Atrial Flutter & Supraventricular Tachycardia

    ClinicalTrials.gov

    2017-12-15

    Atrial Flutter; Tachycardia, Supraventricular; Tachycardia, Atrial Ectopic; Tachycardia, Reciprocating; Tachycardia Atrial; Tachycardia, Atrioventricular Nodal Reentry; Tachycardia, Paroxysmal; Fetal Hydrops

  9. Long-term endurance sport is a risk factor for development of lone atrial flutter.

    PubMed

    Claessen, Guido; Colyn, Erwin; La Gerche, André; Koopman, Pieter; Alzand, Becker; Garweg, Christophe; Willems, Rik; Nuyens, Dieter; Heidbuchel, Hein

    2011-06-01

    To evaluate whether in a population of patients with 'lone atrial flutter', the proportion of those engaged in long-term endurance sports is higher than that observed in the general population. An age and sex-matched retrospective case-control study. A database with 638 consecutive patients who underwent ablation for atrial flutter at the University of Leuven. Sixty-one patients (55 men, 90%) fitted the inclusion criteria of 'lone atrial flutter', ie, aged 65 years or less, without documented atrial fibrillation and without identifiable underlying disease (including hypertension). Sex, age and inclusion criteria-matched controls, two for each flutter patient, were selected in a general practice in the same geographical region. Sports activity was evaluated by detailed questionnaires, which were available in 58 flutter patients (95%). A transthoracic echocardiogram was performed in all lone flutter patients. Types of sports, number of years of participation and average number of hours per week. The proportion of regular sportsmen (≥3 h of sports practice per week) among patients with lone atrial flutter was significantly higher than that observed in the general population (50% vs 17%; p<0.0001). The proportion of sportsmen engaged in long-term endurance sports (participation in cycling, running or swimming for ≥3 h/week) was also significantly higher in lone flutter patients than in controls (31% vs 8%; p=0.0003). Those flutter patients performing endurance sports had a larger left atrium than non-sportsmen (p=0.04, by one-way analysis of variance). A history of endurance sports and subsequent left atrial remodelling may be a risk factor for the development of atrial flutter.

  10. Radiofrequency catheter ablation in patients with symptomatic atrial flutter/tachycardia after orthotopic heart transplantation.

    PubMed

    Li, Yi-gang; Grönefeld, Gerian; Israel, Carsten; Lu, Shang-biao; Wang, Qun-shan; Hohnloser, Stefan H

    2006-12-20

    Atrial tachycardia or flutter is common in patients after orthotopic heart transplantation. Radiofrequency catheter ablation to treat this arrhythmia has not been well defined in this setting. This study was conducted to assess the incidence of various symptomatic atrial arrhythmias and the efficacy and safety of radiofrequency catheter ablation in these patients. Electrophysiological study and catheter ablation were performed in patients with symptomatic tachyarrhythmia. One Halo catheter with 20 poles was positioned around the tricuspid annulus of the donor right atrium, or positioned around the surgical anastomosis when it is necessary. Three quadripolar electrode catheters were inserted via the right or left femoral vein and positioned in the recipient atrium, the bundle of His position, the coronary sinus. Programmed atrial stimulation and burst pacing were performed to prove electrical conduction between the recipient and the donor atria and to induce atrial arrhythmias. Out of 55 consecutive heart transplantation patients, 6 males [(58 +/- 12) years] developed symptomatic tachycardias at a mean of (5 +/- 4) years after heart transplantation. Electrical propagation through the suture line between the recipient and the donor atrium was demonstrated during atrial flutter or during recipient atrium and donor atrium pacing in 2 patients. By mapping around the suture line, the earliest fragmented electrogram of donor atrium was assessed. This electrical connection was successfully ablated in the anterior lateral atrium in both patients. There was no electrical propagation through the suture line in the other 4 patients. Two had typical atrial flutter in the donor atrium which was successfully ablated by completing a linear ablation between the tricuspid annulus and the inferior vena cava. Two patients had atrial tachycardia which was ablated in the anterior septal and lateral donor atrium. There were no procedure-related complications. Patients were free of recurrent atrial tachyarrhythmias after a follow-up of (8 +/- 7) months. Four electrophysiological mechanisms have been found to contribute to the occurrence of symptomatic supraventricular arrhythmias following heart transplantation. Radiofrequency catheter ablation in patients with atrial flutter/tachycardia is feasible and safe after heart transplantation.

  11. Remodeling of sinus node function after catheter ablation of right atrial flutter.

    PubMed

    Daoud, Emile G; Weiss, Raul; Augostini, Ralph S; Kalbfleisch, Steven J; Schroeder, Jason; Polsinelli, Georgia; Hummel, John D

    2002-01-01

    The purpose of this study was to investigate the effect of ablation of right atrial flutter upon sinus node function in humans. This study enrolled 35 patients. Twenty-four patients (16 men and 8 women; age 68 +/- 11 years) were referred for ablation of persistent atrial flutter (duration 8 +/- 11 months). After ablation, there was abnormal sinus node function defined as a corrected sinus node recovery time (CSNRT) > or = 550 msec. The control group consisted of 11 patients who were undergoing pacemaker implantation for sinus node disease but did not have a history of atrial dysrhythmias or ablation. Within 24 hours of ablation or pacemaker implantation, baseline maximal CSNRT was measured through a permanent pacemaker by AAI pacing at six cycle lengths: 600, 550, 500, 450, 400, and 350 msec. CSNRT then was measured in the same manner at 48 hours, 14 days, and 3 months after ablation/pacemaker implantation. P wave amplitude and duration, and percent atrial sensing also were assessed at the same intervals. For patients undergoing atrial flutter ablation, there was progressive temporal recovery of CSNRT (1,204 +/- 671 msec at baseline vs 834 +/- 380 msec at 3 months; P < 0.001) and a significant increase in the percent atrial sensing and P wave amplitude at 3 months compared with baseline (P < 0.001). In control subjects, there was no change in the CSNRT, percent atrial pacing, or P wave amplitude. After ablation of persistent atrial flutter, there is temporal recovery of CSNRT and increase in spontaneous atrial activity. These findings suggest that atrial flutter induces reversible changes in sinus node function.

  12. Effects of linear ablation at the isthmus between the tricuspid annulus and inferior vena cava for atrial flutter on autonomic nervous activity: analysis of heart rate variability.

    PubMed

    Li, Aiyan; Kuga, Keisuke; Suzuki, Akihiro; Endo, Masae; Niho, Bumpei; Enomoto, Mami; Kanemoto, Miyako; Yamaguchi, Iwao

    2002-01-01

    Heart rate is largely affected by the autonomic nervous system. However, little is known about the anatomic pathway of autonomic nerve fibers innervating the sinus node. The present study: (1) evaluates the effects of cavotricuspid isthmus ablation for common atrial flutter (AFL) on autonomic nervous function by using heart rate variability analysis, and (2) investigates the distribution of autonomic nerve pathways innervating the sinus node. Twelve patients with paroxysmal common atrial flutter who maintained sinus rhythm both before and after radiofrequency ablation were selected for the study. Holter ambulatory recordings were performed before and after (2.3 +/- 1.0 days) radiofrequency ablation of cavotricuspid isthmus. Heart rate and time domain (SDANN, rMSSD, pNN50) and frequency domain (low frequency (LF), high frequency (HF), LF/HF) analysis of heart rate variability were compared before and after ablation. Mean heart rate did not change significantly after ablation (59 +/- 6 vs 61 +/- 9 beats/min); parasympathetic indices of heart rate variability (SDANN, rMSSD, pNN50, HF) did not change significantly (110 +/- 37 vs 117 +/- 20 ms; 32 +/- 21 vs 28 +/- 9 ms; 4.8 +/- 0.9 vs 4.7 +/- 0.71n(ms2)); and sympathetic indices of heart rate variability (LF/HF) did not change significantly (1.1 +/- 0.2 vs 1.2 +/- 0.1). Cavotricuspid isthmus ablation for atrial flutter did not significantly change heart rate and heart rate variability because parasympathetic and sympathetic fibers innervating the sinus node are scarce in this region.

  13. Changing axis deviation and paroxysmal atrial flutter associated with subclinical hyperthyroidism.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2010-10-08

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. It has also been reported that increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. Rarely, it has also been reported intermittent changing axis deviation during atrial fibrillation and during atrial flutter. We present a case of paroxysmal atrial flutter and changing axis deviation associated with subclinical hyperthyroidism, in a 76-year-old Italian man. Also this case focuses attention on the importance of a correct evaluation of subclinical hyperthyroidism. Copyright © 2008 Elsevier Ireland Ltd. All rights reserved.

  14. Intermittent changing axis deviation with intermittent left anterior hemiblock during atrial flutter with subclinical hyperthyroidism.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2009-06-26

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with CHD or mortality from cardiovascular causes but it is usually associated with a higher heart rate and a higher risk of supraventricular arrhythmias including atrial fibrillation and atrial flutter. Intermittent changing axis deviation during atrial fibrillation has also rarely been reported. We present a case of intermittent changing axis deviation with intermittent left anterior hemiblock in a 59-year-old Italian man with atrial flutter and subclinical hyperthyroidism. To our knowledge, this is the first report of intermittent changing axis deviation with intermittent left anterior hemiblock in a patient with atrial flutter.

  15. Termination of persistent atrial fibrillation during pulmonary vein isolation: insight from the MAGIC-AF trial.

    PubMed

    Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y

    2017-10-01

    Controversy on the optimal ablation strategy for persistent atrial fibrillation (AF) exists with limited work evaluating a strategy of pulmonary vein isolation (PVI) alone when AF terminates during PVI. Thirty-five patients had AF termination during PVI in the Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF; ClinicalTrials.gov number: NCT01014741) study. The objective of the current study is to report the 1-year outcome after PVI alone in this unique patient group. The 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs was reported for the 35 patients in the MAGIC-AF study with persistent AF termination during or upon completion of PVI. Freedom from recurrent atrial arrhythmia was achieved in 60% of patients where AF terminated during PVI. Cavotricuspid isthmus flutter was common when AF terminated to a macro re-entrant flutter during PVI, and responsible for 92% of all flutter circuits with AF termination. Persistent AF termination during PVI may identify a subgroup of patients who experience a similar long-term clinical outcome with PVI ablation alone when compared with other more extensive persistent AF ablation strategies. Pulmonary vein isolation alone may be an appropriate tactic in this subgroup of persistent AF patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  16. Remote magnetic navigation for accurate, real-time catheter positioning and ablation in cardiac electrophysiology procedures.

    PubMed

    Filgueiras-Rama, David; Estrada, Alejandro; Shachar, Josh; Castrejón, Sergio; Doiny, David; Ortega, Marta; Gang, Eli; Merino, José L

    2013-04-21

    New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Catheter Guidance, Control and Imaging (CGCI) system. Patients who underwent ablation of a right or left atrium flutter substrate were included. Specifically, data from three left atrial flutter and two counterclockwise right atrial flutter procedures are shown in this report. One representative left atrial flutter procedure is shown in the movie. This system is based on eight coil-core electromagnets, which generate a dynamic magnetic field focused on the heart. Remote navigation by rapid changes (msec) in the magnetic field magnitude and a very flexible magnetized catheter allow real-time closed-loop integration and accurate, stable positioning and ablation of the arrhythmogenic substrate.

  17. Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

    PubMed Central

    Filgueiras-Rama, David; Estrada, Alejandro; Shachar, Josh; Castrejón, Sergio; Doiny, David; Ortega, Marta; Gang, Eli; Merino, José L.

    2013-01-01

    New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Catheter Guidance, Control and Imaging (CGCI) system. Patients who underwent ablation of a right or left atrium flutter substrate were included. Specifically, data from three left atrial flutter and two counterclockwise right atrial flutter procedures are shown in this report. One representative left atrial flutter procedure is shown in the movie. This system is based on eight coil-core electromagnets, which generate a dynamic magnetic field focused on the heart. Remote navigation by rapid changes (msec) in the magnetic field magnitude and a very flexible magnetized catheter allow real-time closed-loop integration and accurate, stable positioning and ablation of the arrhythmogenic substrate. PMID:23628883

  18. Survival after extreme left atrial hypertension and pulmonary hemorrhage in an infant supported with extracorporeal membrane oxygenation for refractory atrial flutter.

    PubMed

    Cisco, Michael J; Asija, Ritu; Dubin, Anne M; Perry, Stanton B; Hanley, Frank L; Roth, Stephen J

    2011-05-01

    We report here the survival of an infant who developed extreme left atrial hypertension and severe pulmonary hemorrhage while supported with extracorporeal membrane oxygenation for refractory atrial flutter. The patient recovered after decompression of the left heart and catheter ablation of the atrioventricular node. Lucile Packard Children's Hospital (Stanford, CA). Chart review. Recovery of lung function is possible despite systemic-level left atrial pressure resulting in pulmonary hemorrhage and complete solidification of lung parenchyma on gross inspection. Resolution of pulmonary hemorrhage despite anticoagulation while on extracorporeal membrane oxygenation can occur after relief of left atrial hypertension.

  19. Critical phase transitions during ablation of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Iravanian, Shahriar; Langberg, Jonathan J.

    2017-09-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia with significant morbidity and mortality. Pharmacological agents are not very effective in the management of AF. Therefore, ablation procedures have become the mainstay of AF management. The irregular and seemingly chaotic atrial activity in AF is caused by one or more meandering spiral waves. Previously, we have shown the presence of sudden rhythm organization during ablation of persistent AF. We hypothesize that the observed transitions from a disorganized to an organized rhythm is a critical phase transition. Here, we explore this hypothesis by simulating ablation in an anatomically-correct 3D AF model. In 722 out of 2160 simulated ablation, at least one sudden transition from AF to an organized rhythm (flutter) was noted (33%). They were marked by a sudden decrease in the cycle length entropy and increase in the mean cycle length. At the same time, the number of reentrant wavelets decreased from 2.99 ± 0.06 in AF to 1.76 ± 0.05 during flutter, and the correlation length scale increased from 13.3 ± 1.0 mm to 196.5 ± 86.6 mm (both P < 0.0001). These findings are consistent with the hypothesis that transitions from AF to an anatomical flutter behave as phase transitions in complex non-equilibrium dynamical systems with flutter acting as an absorbing state. Clinically, the facilitation of phase transition should be considered a novel mechanism of ablation and may help to design effective ablation strategies.

  20. Neonatal atrial flutter after insertion of an intracardiac umbilical venous catheter

    PubMed Central

    de Almeida, Marcos Moura; Tavares, Wládia Gislaynne de Sousa; Furtado, Maria Mônica Alencar Araripe; Fontenele, Maria Marcia Farias Trajano

    2016-01-01

    Abstract Objective: To describe a case of neonatal atrial flutter after the insertion of an intracardiac umbilical venous catheter, reporting the clinical presentation and reviewing the literature on this subject. Case description: A late-preterm newborn, born at 35 weeks of gestational age to a diabetic mother and large for gestational age, with respiratory distress and rule-out sepsis, required an umbilical venous access. After the insertion of the umbilical venous catheter, the patient presented with tachycardia. Chest radiography showed that the catheter was placed in the position that corresponds to the left atrium, and traction was applied. The patient persisted with tachycardia, and an electrocardiogram showed atrial flutter. As the patient was hemodynamically unstable, electric cardioversion was successfully applied. Comments: The association between atrial arrhythmias and misplaced umbilical catheters has been described in the literature, but in this case, it is noteworthy that the patient was an infant born to a diabetic mother, which consists in another risk factor for heart arrhythmias. Isolated atrial flutter is a rare tachyarrhythmia in the neonatal period and its identification is essential to establish early treatment and prevent systemic complications and even death. PMID:26525686

  1. Achieving Bidirectional Long Delays In Pulmonary Vein Antral Lines Prior To Bidirectional Block In Patients With Paroxysmal Atrial Fibrillation (The Bi-Bi Technique For Atrial Fibrillation Ablation).

    PubMed

    Mina, Adel F; Warnecke, Nicholas L

    2016-01-01

    Background: Pulmonary Vein Antral isolation (PVAI) is currently the standard of care for both paroxysmal and persistent atrial fibrillation ablation. Reconnection to the pulmonary vein is the most common cause of recurrence of atrial fibrillation. Achieving the endpoint of bidirectional block (BDB) for cavotricuspid isthmus dependant flutter has improved our outcomes for atrial flutter ablation. With this we tried to achieve long delays in the pulmonary veins antral lines prior to complete isolation comparable to those delays found in patient with bidirectional block of atrial flutter lines. Study Objective: The objective of this paper was to evaluate feasibility and efficacy of achieving Bidirectional long delays in pulmonary vein antral lines prior to Bidirectional Block in patient with paroxysmal atrial fibrillation. Method: A retrospective analysis was performed on patients who had paroxysmal atrial fibrillation procedures at Unity Point Methodist from January 2015 to January 2016. 20 consecutive patients with paroxysmal atrial fibrillation who had AF ablation using the Bi-Bi technique were evaluated. Result: Mean age was 63, number of antiarrhythmic used prior to ablation was 1.4, mean left atrial size was 38 mm. Mean chads score was 1.3. Mean EF was 53%. Long delays in the left antral circumferential lines were achieved with mean delay of 142 milliseconds +/-100. Also long delays in the right antral circumferential lines were achieved with mean delay of 150 milliseconds +/-80. 95 % (19/20) of patients were free of any atrial arrhythmias and were off antiarrhythmic medications for AF post procedure. There was only one transient complication in one patient who developed a moderate pericardial effusion that was successfully drained with no hemodynamic changes. The only patient who had recurrence was found to have asymptomatic AF with burden on his device <1%, this patient was also found to have non PV triggers for his AF. In patients with only PV triggered AF success rate was 100%. Conclusion: Achievement of Bidirectional long delays in pulmonary vein antral lines prior to Bidirectional Block in patient with paroxysmal atrial fibrillation is feasible and highly effective technique in this small cohort of patients studied. We also outlined the procedure in details.

  2. Dronedarone: drondarone, SR 33589, SR 33589B.

    PubMed

    2007-01-01

    Dronedarone, a potassium channel antagonist, is chemically related to amio-darone. It is being developed by sanofi-aventis as a class III antiarrhythmic agent for the treatment of atrial fibrillation and atrial flutter in the US and Europe. Dronedarone has a favourable benefit/risk ratio, with the absence of any proarrhythmic effects. Sanofi merged with Synthélabo to form Sanofi-Synthélabo in 1999. In August 2004, Sanofi-Synthelabo merged with Aventis to form sanofi-aventis. The ATHENA trial is a multinational, randomised, double-blind trial evaluating the effects of dronedarone (400mg bid) compared with placebo, over a minimum 12-month follow-up period, in patients with atrial fibrillation or flutter. The trial is investigating the efficacy of dronedarone in preventing cardiovascular hospitalisations or death from any cause. Enrolment was extended to 4300 patients in order to attain the planned rate of adverse events; patient recruitment is ongoing.Previously, sanofi-aventis completed two pivotal phase III trials in atrial fibrillation. The trials, EURIDIS (EURopean trial In atrial fibrillation or flutter patients for the maintenance of Sinus rhythm) and ADONIS (American-Australasian trial with DronedarONe In atrial fibrillation or flutter patients for the maintenance of Sinus rhythm), involved 1237 patients who were in sinus rhythm at the time of randomisation. Results showed dronedarone to have anti-arrhythmic effects and a favourable benefit/risk ratio, with the absence of any proarrhythmic effect.Another trial, ERATO (Efficacy and safety of dronedARone for The cOntrol of ventricular rate), took place in 35 centres across nine European countries assessing dronedarone in 174 patients with permanent atrial fibrillation. Dronedarone was in phase II trials in Japan for the treatment of atrial fibrillation; however, no recent developments have been reported.

  3. Pre-injection of magnesium sulfate enhances the efficacy of ibutilide for the conversion of typical but not of atypical persistent atrial flutter.

    PubMed

    Steinwender, Clemens; Hönig, Simon; Kypta, Alexander; Kammler, Jürgen; Schmitt, Barbara; Leisch, Franz; Hofmann, Robert

    2010-06-11

    Ibutilide is a class III antiarrhythmic drug, frequently used for conversion of atrial fibrillation and flutter. Retrospective cohort evaluations found that intravenous application of magnesium enhances the efficacy of ibutilide for chemical conversion of these arrhythmias. This prospective study sought to investigate the effects of intravenously pre-injected magnesium on the conversion rate of ibutilide for typical and atypical atrial flutter. We performed a prospective, randomized, placebo-controlled study. Patients with typical atrial flutter (TAF) or atypical atrial flutter (AAF) were randomized to receive either 4 g of intravenous magnesium sulfate or placebo immediately before administration of a maximum dose of 2 mg of ibutilide fumarate. Continuous rhythm monitoring for 4 h provided information on conversion to sinus rhythm. QT interval durations were measured before randomization, after magnesium, as well as 30 min and 4 h after starting ibutilide infusion. We randomized 117 patients (58 with and 59 without pre-injection of magnesium; 65 with TAF and 52 with AAF). In patients with TAF, pre-injection of magnesium significantly improved the efficacy of ibutilide for conversion (85% with magnesium vs. 59% with placebo, p=0.017). In patients with AAF, no significant difference in conversion rates between patients receiving magnesium or placebo was detected (48% vs. 56%, p=0.189). Pre-injection of magnesium did not significantly influence the QT intervals at any time after administration of ibutilide. Pre-injection of magnesium significantly enhances the efficacy of ibutilide for the conversion of TAF but not of AAF. Copyright (c) 2008 Elsevier Ireland Ltd. All rights reserved.

  4. Atrial Macroreentry in Congenital Heart Disease

    PubMed Central

    Twomey, Darragh J; Sanders, Prashanthan; Roberts-Thomson, Kurt C

    2015-01-01

    Macroreentrant atrial tachycardia is a common complication following surgery for congenital heart disease (CHD), and is often highly symptomatic with potentially significant hamodynamic consequences. Medical management is often unsuccessful, requiring the use of invasive procedures. Cavotricuspid isthmus dependent flutter is the most common circuit but atypical circuits also exist, involving sites of surgical intervention or areas of scar related to abnormal hemodynamics. Ablation can be technically challenging, due to complex anatomy, and difficulty with catheter stability. A thorough assessment of the pa-tients status and pre-catheter ablation planning is critical to successfully managing these patients. PMID:25308809

  5. Congenital toxoplasmosis presenting with fetal atrial flutter after maternal ingestion of infected moose meat.

    PubMed

    Colosimo, Sarah M; Montoya, Jose G; Westley, Benjamin P; Jacob, Jack; Isada, Nelson B

    2013-09-01

    Consumption of undercooked game meat during pregnancy is considered a risk factor for congenital toxoplasmosis, but cases definitively linking ingestion of infected meat to clinical disease are lacking. We report a confirmed case of congenital toxoplasmosis identified because of atrial flutter in the fetus and linked to maternal consumption of Toxoplasma gondii PCR-positive moose meat.

  6. Prognosis and guideline-adherent antithrombotic treatment in patients with atrial fibrillation and atrial flutter: implications of undertreatment and overtreatment in real-life clinical practice; the Loire Valley Atrial Fibrillation Project.

    PubMed

    Gorin, Laurent; Fauchier, Laurent; Nonin, Emilie; Charbonnier, Bernard; Babuty, Dominique; Lip, Gregory Y H

    2011-10-01

    In patients with atrial fibrillation (AF), adherence to guidelines for antithrombotic treatment is poorly followed, and undertreatment (or nonadherence with guidelines) is associated with a worse prognosis. The study objective was to evaluate whether this was also the case in a large contemporary series of unselected patients with AF in real-world clinical practice. All patients with AF or atrial flutter seen in our institution between 2000 and 2007 were identified in a database and followed up for mortality and stroke. Antithrombotic guideline adherence was assessed according to the 2006 American College of Cardiology/American Heart Association/European Society of Cardiology guidelines. We reviewed outcomes in 3,646 consecutive patients with AF or atrial flutter (aged 71 ± 14 years; mean CHADS(2) [congestive heart failure, hypertension, aged ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack] score, 1.5 ± 1.1). Antithrombotic treatment was in agreement with the guidelines in 53% of patients, whereas 31% were classified as undertreated and 16% as overtreated. Among other parameters, nonpermanent AF and atrial flutter were independently associated with an increased risk of undertreatment. After a follow-up of 953 ± 767 days (median, 771 days; interquartile range, 1,286 days), guideline adherence was associated with a lower risk of adverse events (death from all causes or stroke) compared with undertreatment (relative risk, 0.47; 95% CI, 0.40-0.55; P < .0001). Overtreatment was associated with a lower risk of adverse events compared with the guideline-adherent population (relative risk, 0.40; 95% CI, 0.28-0.58; P < .0001). Factors independently associated with increased risk of mortality or stroke were antithrombotic undertreatment, older age, heart failure, renal failure, diabetes, male sex, and previous history of stroke. Guideline nonadherence and undertreatment with antithrombotic agents in unselected real-world patients with AF or atrial flutter are independently associated with a high risk of stroke and mortality.

  7. Atrial flutter with 1:1 conduction in undiagnosed Wolff-Parkinson-White syndrome.

    PubMed

    Nelson, Jessie G; Zhu, Dennis W

    2014-05-01

    Atrial flutter with 1:1 atrioventricular conduction via an accessory pathway is an uncommon presentation of Wolff-Parkinson-White syndrome not previously reported in the emergency medicine literature. Wolff-Parkinson-White syndrome, a form of ventricular preexcitation sometimes initially seen and diagnosed in the emergency department (ED), can present with varied tachydysrhythmias for which certain treatments are contraindicated. For instance, atrial fibrillation with preexcited conduction needs specific consideration of medication choice to avoid potential degeneration into ventricular fibrillation. We describe an adult female presenting with a very rapid, regular wide complex tachycardia successfully cardioverted in the ED followed by a normal electrocardiogram (ECG). Electrophysiology study confirmed atrial flutter with 1:1 conduction and revealed an accessory pathway consistent with Wolff-Parkinson-White syndrome, despite lack of ECG findings of preexcitation during sinus rhythm. Why should an emergency physician be aware of this? Ventricular tachycardia must be the first consideration in patients with regular wide complex tachycardia. However, clinicians should consider atrial flutter with 1:1 conduction related to an accessory pathway when treating patients with the triad of very rapid rate (>250 beats/min), wide QRS complex, and regular rhythm, especially when considering pharmacologic treatment. Emergency physicians also should be aware of electrocardiographically concealed accessory pathways, and that lack of delta waves does not rule out preexcitation syndromes such as Wolff-Parkinson-White syndrome. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Association of the Ottawa Aggressive Protocol with rapid discharge of emergency department patients with recent-onset atrial fibrillation or flutter.

    PubMed

    Stiell, Ian G; Clement, Catherine M; Perry, Jeffrey J; Vaillancourt, Christian; Symington, Cheryl; Dickinson, Garth; Birnie, David; Green, Martin S

    2010-05-01

    There is no consensus on the optimal management of recent-onset episodes of atrial fibrillation or flutter. The approach to these conditions is particularly relevant in the current era of emergency department (ED) overcrowding. We sought to examine the effectiveness and safety of the Ottawa Aggressive Protocol to perform rapid cardioversion and discharge patients with these arrhythmias. This cohort study enrolled consecutive patient visits to an adult university hospital ED for recent-onset atrial fibrillation or flutter managed with the Ottawa Aggressive Protocol. The protocol includes intravenous chemical cardioversion, electrical cardioversion if necessary and discharge home from the ED. A total of 660 patient visits were included, 95.2% involving atrial fibrillation and 4.9% involving atrial flutter. The mean age of patients enrolled was 64.5 years. In total, 96.8% were discharged home and, of those, 93.3% were in sinus rhythm. All patients were initially administered intravenous procainamide, with a 58.3% conversion rate. A total of 243 patients underwent subsequent electrical cardioversion with a 91.7% success rate. Adverse events occurred in 7.6% of cases: hypotension 6.7%, bradycardia 0.3% and 7-day relapse 8.6%. There were no cases of torsades de pointes, stroke or death. The median lengths of stay in the ED were as follows: 4.9 hours overall, 3.9 hours for those undergoing conversion with procainamide and 6.5 hours for those requiring electrical conversion. This is the largest study to date to evaluate the Ottawa Aggressive Protocol, a unique approach to cardioversion for ED patients with recent-onset episodes of atrial fibrillation and flutter. Our data demonstrate that the Ottawa Aggressive Protocol is effective, safe and rapid, and has the potential to significantly reduce hospital admissions and expedite ED care.

  9. Start or STop Anticoagulants Randomised Trial (SoSTART)

    ClinicalTrials.gov

    2018-06-26

    Intracranial Hemorrhages; Intracranial Hemorrhage, Hypertensive; Subarachnoid Hemorrhage; Subdural Hematoma; Intraventricular Hemorrhage; Atrial Fibrillation; Atrial Flutter; Small Vessel Cerebrovascular Disease; Microhaemorrhage

  10. Right Ventricular Pacing for Assessment of Cavo-Tricuspid Isthmus Block.

    PubMed

    Venkataraman, Ganesh; Wish, Marc; Friehling, Ted; Strickberger, S Adam

    2016-01-01

    Background: Cavo-tricuspid isthmus (CTI) dependent atrial flutter is typically treated with cardiac ablation. Standard techniques to assess CTI block after ablation can be technically challenging. Right ventricular (RV) pacing may allow for another technique to assess CTI block after ablation. Objective: The purpose of this study was to evaluate RV pacing as a method to assess CTI block after ablation of CTI dependent atrial flutter, and define endpoints of ablation using this technique. Methods: 28 patients undergoing ablation of CTI dependent atrial flutter with intact ventriculoatrial (VA) conduction were prospectively enrolled in this study and underwent the RV pacing protocol, as well as standard coronary sinus (CS) pacing techniques to assess CTI block. Results: The mean trans-isthmus conduction interval during CS pacing (TICI CS ) at 600 and 400ms after CTI ablation was 168 +/- 9ms and 175 +/- 18ms, respectively. The mean trans-isthmus conduction interval during RV pacing (TICI RV ) at 600ms and 400ms after CTI ablation was 109 +/- 5ms and 111 +/- 5ms, respectively. A TICI RV >100ms was associated with a successful outcome after CTI ablation. Conclusions: RV pacing may add incremental value in the assessment of CTI block in patients undergoing ablation of CTI dependent atrial flutter.

  11. SHERLOCK 3CG™ Diamond Tip Confirmation System

    ClinicalTrials.gov

    2018-05-15

    Indication for Peripheral Intravenous Catheterization; Atrial Flutter; Premature Atrial Contraction; Premature Ventricular Contraction; Premature Junctional Contraction; Tachycardia; Atrioventricular Block; Bundle-Branch Block

  12. Contemporary Diagnosis and Management of Atrial Flutter: A Continuum of Atrial Fibrillation and Vice Versa?

    PubMed

    Manolis, Antonis S

    Atrial flutter (AFlu) is usually a fast (>240 bpm) and regular right atrial macroreentrant tachycardia, with a constrained critical region of the reentry circuit located at the cavotricuspid isthmus (CTI; typical CTI-dependent AFlu). However, a variety of right and left atrial tachycardias, resulting from different mechanisms, can also present as AFlu (atypical non-CTI-dependent AFlu). The electrocardiogram can provide clues to its origin and location; however, additional entrainment and more sophisticated electroanatomical mapping techniques may be required to identify its mechanism, location, and target area for a successful ablation. Although atrial fibrillation and AFlu are 2 separate arrhythmias, they often coexist before and after drug and/or ablation therapies. Indeed, there appears to be a close interrelationship between these 2 arrhythmias, and one may "transform" into the other. These issues are discussed in this overview, and practical algorithms are proposed to guide AFlu localization and illustrate the AFlu and atrial fibrillation continuum.

  13. [Prophylaxis of thromboembolism in atrial fibrillation: new oral anticoagulants and left atrial appendage closure].

    PubMed

    Zeus, Tobias; Kelm, Malte; Bode, Christoph

    2015-08-01

    Thrombo-embolic prophylaxis is a key element within the therapy of atrial fibrillation/atrial flutter. Besides new oral anticoagulants the concept of left atrial appendage occlusion has approved to be a good alternative option, especially in patients with increased risk of bleeding. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Anatomic Guidance For Ablation: Atrial Flutter, Fibrillation, and Outflow Tract Ventricular Tachycardia

    PubMed Central

    Sehar, Nandini; Mears, Jennifer; Bisco, Susan; Patel, Sandeep; Lachman, Nirusha; Asirvatham, Samuel J

    2010-01-01

    After initial documentation of excellent efficacy with radiofrequency ablation, this procedure is being performed increasingly in more complex situations and for more difficult arrhythmia. In these circumstances, an accurate knowledge of the anatomic basis for the ablation procedure will help maintain this efficacy and improve safety. In this review, we discuss the relevant anatomy for electrophysiology interventions for typical right atrial flutter, atrial fibrillation, and outflow tract ventricular tachycardia. In the pediatric population, maintaining safety is a greater challenge, and here again, knowing the neighboring and regional anatomy of the arrhythmogenic substrate for these arrhythmias may go a long way in preventing complications. PMID:20811537

  15. Early cardioversion of atrial fibrillation and atrial flutter guided by transoesophageal echocardiography: a single centre 8.5-year experience.

    PubMed

    Corrado, G; Santarone, M; Beretta, S; Tadeo, G; Tagliagambe, L M; Foglia-Manzillo, G; Spata, M; Miglierina, E; Acquati, F; Santarone, M

    2000-04-01

    To analyse the safety and impact on maintenance of sinus rhythm of transoesophageal echocardiographically guided early cardioversion associated with short-term anticoagulation in a large series of patients with atrial fibrillation and atrial flutter. Patients who were candidates for cardioversion were eligible for inclusion if they had atrial fibrillation or atrial flutter lasting longer than 2 days or of unknown duration. Patients received short-term anticoagulation with warfarin or heparin and underwent transthoracic echocardiography followed by transoesophageal echocardiography. Early cardioversion was performed if no thrombus was seen on the transoesophageal study. Warfarin was maintained for 1 month after cardioversion. In patients with atrial thrombi, cardioversion was deferred and prolonged anticoagulation was prescribed. The study population included 183 patients. One hundred and sixty nine patients without atrial thrombi underwent early cardioversion. Fourteen patients with atrial thrombi (7.6%) underwent a second transoesophageal echocardiogram after a median of 4 weeks of oral warfarin, and cardioversion was performed if clot regression was documented. No patient in our study population had a clinical thromboembolic event at 1 month follow-up (95% C.I. 0-0.016). The immediate success rate of cardioversion was better among patients with atrial fibrillation < 4 weeks duration compared with patients with atrial fibrillation of longer or of unknown duration: 96.6% vs 85%, respectively (P = 0.014). At 1 month follow-up, the percentage of arrhythmia relapses in patients with initially successful cardioversion was similar in the two groups (29% vs 26%, P = ns); thus the initial better outcome in patients with recent-onset arrhythmia was not lost. Transoesophageal echocardiography-guided early cardioversion in concert with short-term anticoagulation is safe. This approach permits abbreviation of the overall duration of atrial fibrillation and has a better impact on the maintenance of sinus rhythm for patients in whom the duration of atrial fibrillation is < 4 weeks.

  16. Assessing the Atrial Electromechanical Coupling during Atrial Focal Tachycardia, Flutter, and Fibrillation using Electromechanical Wave Imaging in Humans

    PubMed Central

    Provost, Jean; Costet, Alexandre; Wan, Elaine; Gambhir, Alok; Whang, William; Garan, Hasan; Konofagou, Elisa E.

    2015-01-01

    Minimally-invasive treatments of cardiac arrhythmias such as radio-frequency ablation are gradually gaining in importance in clinical practice but still lack a noninvasive imaging modality which provides insight into the source or focus of an arrhythmia. Cardiac deformations imaged at high temporal and spatial resolution can be used to elucidate the electrical activation sequence in normal and paced human subjects non-invasively and could potentially aid to better plan and monitor ablation-based arrhythmia treatments. In this study, a novel ultrasound-based method is presented that can be used to quantitatively characterize focal and reentrant arrhythmias. Spatio-temporal maps of the full-view of the atrial and ventricular mechanics were obtained in a single heartbeat, revealing with otherwise unobtainable detail the electromechanical patterns of atrial flutter, fibrillation, and tachycardia in humans. During focal arrhythmias such as premature ventricular complex and focal atrial tachycardia, the previously developed electromechanical wave imaging methodology is hereby shown capable of identifying the location of the focal zone and the subsequent propagation of cardiac activation. During reentrant arrhythmias such as atrial flutter and fibrillation, Fourier analysis of the strains revealed highly correlated mechanical and electrical cycle lengths and propagation patterns. High frame rate ultrasound imaging of the heart can be used non-invasively and in real time, to characterize the lesser-known mechanical aspects of atrial and ventricular arrhythmias, also potentially assisting treatment planning for intraoperative and longitudinal monitoring of arrhythmias. PMID:26361338

  17. Dronedarone for the treatment of atrial fibrillation and atrial flutter: approval and efficacy.

    PubMed

    Wolbrette, Deborah; Gonzalez, Mario; Samii, Soraya; Banchs, Javier; Penny-Peterson, Erica; Naccarelli, Gerald

    2010-08-09

    Dronedarone, a new Class III antiarrhythmic agent, has now been approved by the US Food and Drug Administration for use in patients with atrial fibrillation or atrial flutter. Approval came in March 2009 due to the positive results of the ATHENA trial showing significant reductions in all-cause mortality and cardiovascular hospitalization with dronedarone use. A post hoc analysis of the ATHENA data also suggested a decrease in stroke risk with this agent. However, due to safety concerns in the heart failure population in the earlier ANDROMEDA trial, dronedarone is not recommended for patients with an ejection fraction <35% and recent decompensated heart failure. Dronedarone is an amiodarone analog with multichannel blocking electrophysiologic properties similar to those of amiodarone, but several structural differences. Dronedarone's lack of the iodine moiety reduces its potential for thyroid and pulmonary toxicity. Preliminary data from the DIONYSOS trial, and an indirect meta-analysis comparing amiodarone with dronedarone, showed amiodarone to be more effective in maintaining sinus rhythm, while dronedarone was associated with fewer adverse effects resulting in early termination of the drug. Dronedarone is the first antiarrhythmic drug for the treatment of atrial fibrillation and atrial flutter shown to reduce cardiovascular hospitalizations. In patients with structural heart disease who have an ejection fraction >35% and no recent decompensated heart failure, dronedarone should be considered earlier than amiodarone in the treatment algorithm.

  18. 76 FR 9018 - National Center for Health Statistics (NCHS), Classifications and Public Health Data Standards...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-16

    ...: Acute kidney injury Acute interstitial pneumonia (re-presentation) Atrial fibrillation Highly calcified... encephalomyelitis Acute necrotizing hemorrhagic encephalopathy Atrial fibrillation and flutter Benign shuddering... resurfacing Lead extraction Left atrial appendage exclusion femoral/epicardial access Neuroflow endovascular...

  19. Atriocaval Rupture After Right Atrial Isthmus Ablation for Atrial Flutter.

    PubMed

    Vloka, Caroline; Nelson, Daniel W; Wetherbee, Jule

    2016-06-01

    A patient with symptomatic typical atrial flutter (AFL) underwent right atrial isthmus ablation with an 8-mm catheter. Eight months later, his typical AFL recurred. Ten months later, he underwent a repeat right atrial isthmus ablation with an irrigated tip catheter and an 8-mm tip catheter. Six weeks after his second procedure, while performing intense sprint intervals on a treadmill, he developed an abrupt onset of chest pain, hypotension, and cardiac tamponade. He underwent emergency surgery to repair an atriocaval rupture and has done well since. Our report suggests that an association of multiple radiofrequency ablations with increased risk for delayed atriocaval rupture occurring 1 to 3 months after ablation. In conclusion, although patients generally were advised to limit exercise for 1 to 2 weeks after AFL ablation procedures in the past, it may be prudent to avoid intense exercise for at least 3 months after procedure. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Rates of Atrial Fibrillation in Black Versus White Patients With Pacemakers.

    PubMed

    Kamel, Hooman; Kleindorfer, Dawn O; Bhave, Prashant D; Cushman, Mary; Levitan, Emily B; Howard, George; Soliman, Elsayed Z

    2016-02-12

    Black US residents experience higher rates of ischemic stroke than white residents but have lower rates of clinically apparent atrial fibrillation (AF), a strong risk factor for stroke. It is unclear whether black persons truly have less AF or simply more undiagnosed AF. We obtained administrative claims data from state health agencies regarding all emergency department visits and hospitalizations in California, Florida, and New York. We identified a cohort of patients with pacemakers, the regular interrogation of which reduces the likelihood of undiagnosed AF. We compared rates of documented AF or atrial flutter at follow-up visits using Kaplan-Meier survival statistics and Cox proportional hazards models adjusted for demographic characteristics and vascular risk factors. We identified 10 393 black and 91 380 white patients without documented AF or atrial flutter before or at the index visit for pacemaker implantation. During 3.7 (±1.8) years of follow-up, black patients had a significantly lower rate of AF (21.4%; 95% CI 19.8-23.2) than white patients (25.5%; 95% CI 24.9-26.0). After adjustment for demographic characteristics and comorbidities, black patients had a lower hazard of AF (hazard ratio 0.91; 95% CI 0.86-0.96), a higher hazard of atrial flutter (hazard ratio 1.29; 95% CI 1.11-1.49), and a lower hazard of the composite of AF or atrial flutter (hazard ratio 0.94; 95% CI 0.88-99). In a population-based sample of patients with pacemakers, black patients had a lower rate of AF compared with white patients. These findings indicate that the persistent racial disparities in rates of ischemic stroke are likely to be related to factors other than undiagnosed AF. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  1. Canadian Cardiovascular Society atrial fibrillation guidelines 2010: prevention of stroke and systemic thromboembolism in atrial fibrillation and flutter.

    PubMed

    Cairns, John A; Connolly, Stuart; McMurtry, Sean; Stephenson, Michael; Talajic, Mario

    2011-01-01

    The stroke rate in atrial fibrillation is 4.5% per year, with death or permanent disability in over half. The risk of stroke varies from under 1% to over 20% per year, related to the risk factors of congestive heart failure, hypertension, age, diabetes, and prior stroke or transient ischemic attack (TIA). Major bleeding with vitamin K antagonists varies from about 1% to over 12% per year and is related to a number of risk factors. The CHADS(2) index and the HAS-BLED score are useful schemata for the prediction of stroke and bleeding risks. Vitamin K antagonists reduce the risk of stroke by 64%, aspirin reduces it by 19%, and vitamin K antagonists reduce the risk of stroke by 39% when directly compared with aspirin. Dabigatran is superior to warfarin for stroke prevention and causes no increase in major bleeding. We recommend that all patients with atrial fibrillation or atrial flutter, whether paroxysmal, persistent, or permanent, should be stratified for the risk of stroke and for the risk of bleeding and that most should receive antithrombotic therapy. We make detailed recommendations as to the preferred agents in various types of patients and for the management of antithrombotic therapies in the common clinical settings of cardioversion, concomitant coronary artery disease, surgical or diagnostic procedures with a risk of major bleeding, and the occurrence of stroke or major bleeding. Alternatives to antithrombotic therapies are briefly discussed. Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Atrial flutter after surgical maze: incidence, diagnosis, and management.

    PubMed

    Dresen, William; Mason, Pamela K

    2016-01-01

    The prevalence of atrial fibrillation is increasing and surgical ablation is becoming more common, both as a stand-alone procedure and when performed concomitantly with other cardiac surgery. Although surgical ablation is effective, with it unique challenges arise, including iatrogenic macroreentrant tachycardias that are often highly symptomatic and difficult to manage conservatively. Postsurgical ablation, localization of the arrhythmic circuit is difficult to determine using surface ECG alone because of alterations in the atrial myocardium, and multiple different pathways are often present. Most, however, localize to the left atrium, and percutaneous catheter ablation is emerging as an effective treatment modality. Patients with complex postoperative arrhythmias should be referred to a dedicated atrial fibrillation center when possible and symptomatic arrhythmias mapped and ablated. Knowledge of the previously performed surgical lesion set is of vital importance in understanding the mechanism of the arrhythmia and increasing procedural success rates. http://links.lww.com/HCO/A31.

  3. Diltiazem vs. Metoprolol in the Management of Atrial Fibrillation or Flutter with Rapid Ventricular Rate in the Emergency Department.

    PubMed

    Fromm, Christian; Suau, Salvador J; Cohen, Victor; Likourezos, Antonios; Jellinek-Cohen, Samantha; Rose, Jonathan; Marshall, John

    2015-08-01

    Diltiazem (calcium channel blocker) and metoprolol (beta-blocker) are both commonly used to treat atrial fibrillation/flutter (AFF) in the emergency department (ED). However, there is considerable regional variability in emergency physician practice patterns and debate among physicians as to which agent is more effective. To date, only one small prospective, randomized trial has compared the effectiveness of diltiazem and metoprolol for rate control of AFF in the ED and concluded no difference in effectiveness between the two agents. Our aim was to compare the effectiveness of diltiazem with metoprolol for rate control of AFF in the ED. A convenience sample of adult patients presenting with rapid atrial fibrillation or flutter was randomly assigned to receive either diltiazem or metoprolol. The study team monitored each subject's systolic and diastolic blood pressures and heart rates for 30 min. In the first 5 min, 50.0% of the diltiazem group and 10.7% of the metoprolol group reached the target heart rate (HR) of <100 beats per minute (bpm) (p < 0.005). By 30 min, 95.8% of the diltiazem group and 46.4% of the metoprolol group reached the target HR < 100 bpm (p < 0.0001). Mean decrease in HR for the diltiazem group was more rapid and substantial than that of the metoprolol group. From a safety perspective, there was no difference between the groups with respect to hypotension (systolic blood pressure < 90 mm Hg) and bradycardia (HR < 60 bpm). Diltiazem was more effective in achieving rate control in ED patients with AFF and did so with no increased incidence of adverse effects. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Managing atrial fibrillation in the elderly: critical appraisal of dronedarone.

    PubMed

    Trigo, Paula; Fischer, Gregory W

    2012-01-01

    Atrial fibrillation is the most commonly seen arrhythmia in the geriatric population and is associated with increased cardiovascular morbidity and mortality. Treatment of the elderly with atrial fibrillation remains challenging for physicians, because this unique subpopulation is characterized by multiple comorbidities requiring chronic use of numerous medications, which can potentially lead to severe drug interactions. Furthermore, age-related changes in the cardiovascular system as well as other physiological changes result in altered drug pharmacokinetics. Dronedarone is a new drug recently approved for the treatment of arrhythmias, such as atrial fibrillation and/or atrial flutter. Dronedarone is a benzofuran amiodarone analog which lacks the iodine moiety and contains a methane sulfonyl group that decreases its lipophilicity. These differences in chemical structure are responsible for making dronedarone less toxic than amiodarone which, in turn, results in fewer side effects. Adverse events for dronedarone include gastrointestinal side effects and rash. No dosage adjustments are required for patients with renal impairment. However, the use of dronedarone is contraindicated in the presence of severe hepatic dysfunction.

  5. Migraine and risk of cardiovascular diseases: Danish population based matched cohort study

    PubMed Central

    Szépligeti, Szimonetta Komjáthiné; Holland-Bill, Louise; Ehrenstein, Vera; Horváth-Puhó, Erzsébet; Henderson, Victor W; Sørensen, Henrik Toft

    2018-01-01

    Abstract Objective To examine the risks of myocardial infarction, stroke (ischaemic and haemorrhagic), peripheral artery disease, venous thromboembolism, atrial fibrillation or atrial flutter, and heart failure in patients with migraine and in a general population comparison cohort. Design Nationwide, population based cohort study. Setting All Danish hospitals and hospital outpatient clinics from 1995 to 2013. Participants 51 032 patients with migraine and 510 320 people from the general population matched on age, sex, and calendar year. Main outcome measures Comorbidity adjusted hazard ratios of cardiovascular outcomes based on Cox regression analysis. Results Higher absolute risks were observed among patients with incident migraine than in the general population across most outcomes and follow-up periods. After 19 years of follow-up, the cumulative incidences per 1000 people for the migraine cohort compared with the general population were 25 v 17 for myocardial infarction, 45 v 25 for ischaemic stroke, 11 v 6 for haemorrhagic stroke, 13 v 11 for peripheral artery disease, 27 v 18 for venous thromboembolism, 47 v 34 for atrial fibrillation or atrial flutter, and 19 v 18 for heart failure. Correspondingly, migraine was positively associated with myocardial infarction (adjusted hazard ratio 1.49, 95% confidence interval 1.36 to 1.64), ischaemic stroke (2.26, 2.11 to 2.41), and haemorrhagic stroke (1.94, 1.68 to 2.23), as well as venous thromboembolism (1.59, 1.45 to 1.74) and atrial fibrillation or atrial flutter (1.25, 1.16 to 1.36). No meaningful association was found with peripheral artery disease (adjusted hazard ratio 1.12, 0.96 to 1.30) or heart failure (1.04, 0.93 to 1.16). The associations, particularly for stroke outcomes, were stronger during the short term (0-1 years) after diagnosis than the long term (up to 19 years), in patients with aura than in those without aura, and in women than in men. In a subcohort of patients, the associations persisted after additional multivariable adjustment for body mass index and smoking. Conclusions Migraine was associated with increased risks of myocardial infarction, ischaemic stroke, haemorrhagic stroke, venous thromboembolism, and atrial fibrillation or atrial flutter. Migraine may be an important risk factor for most cardiovascular diseases. PMID:29386181

  6. Migraine and risk of cardiovascular diseases: Danish population based matched cohort study.

    PubMed

    Adelborg, Kasper; Szépligeti, Szimonetta Komjáthiné; Holland-Bill, Louise; Ehrenstein, Vera; Horváth-Puhó, Erzsébet; Henderson, Victor W; Sørensen, Henrik Toft

    2018-01-31

    To examine the risks of myocardial infarction, stroke (ischaemic and haemorrhagic), peripheral artery disease, venous thromboembolism, atrial fibrillation or atrial flutter, and heart failure in patients with migraine and in a general population comparison cohort. Nationwide, population based cohort study. All Danish hospitals and hospital outpatient clinics from 1995 to 2013. 51 032 patients with migraine and 510 320 people from the general population matched on age, sex, and calendar year. Comorbidity adjusted hazard ratios of cardiovascular outcomes based on Cox regression analysis. Higher absolute risks were observed among patients with incident migraine than in the general population across most outcomes and follow-up periods. After 19 years of follow-up, the cumulative incidences per 1000 people for the migraine cohort compared with the general population were 25 v 17 for myocardial infarction, 45 v 25 for ischaemic stroke, 11 v 6 for haemorrhagic stroke, 13 v 11 for peripheral artery disease, 27 v 18 for venous thromboembolism, 47 v 34 for atrial fibrillation or atrial flutter, and 19 v 18 for heart failure. Correspondingly, migraine was positively associated with myocardial infarction (adjusted hazard ratio 1.49, 95% confidence interval 1.36 to 1.64), ischaemic stroke (2.26, 2.11 to 2.41), and haemorrhagic stroke (1.94, 1.68 to 2.23), as well as venous thromboembolism (1.59, 1.45 to 1.74) and atrial fibrillation or atrial flutter (1.25, 1.16 to 1.36). No meaningful association was found with peripheral artery disease (adjusted hazard ratio 1.12, 0.96 to 1.30) or heart failure (1.04, 0.93 to 1.16). The associations, particularly for stroke outcomes, were stronger during the short term (0-1 years) after diagnosis than the long term (up to 19 years), in patients with aura than in those without aura, and in women than in men. In a subcohort of patients, the associations persisted after additional multivariable adjustment for body mass index and smoking. Migraine was associated with increased risks of myocardial infarction, ischaemic stroke, haemorrhagic stroke, venous thromboembolism, and atrial fibrillation or atrial flutter. Migraine may be an important risk factor for most cardiovascular diseases. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Linear ablation of right atrial free wall flutter: demonstration of bidirectional conduction block as an endpoint associated with long-term success.

    PubMed

    Snowdon, Richard L; Balasubramaniam, Richard; Teh, Andrew W; Haqqani, Haris M; Medi, Caroline; Rosso, Raphael; Vohra, Jitendra K; Kistler, Peter M; Morton, Joseph B; Sparks, Paul B; Kalman, Jonathan M

    2010-05-01

    Ablation for atypical atrial flutter (AFL) is often performed during tachycardia, with termination or noninducibility of AFL as the endpoint. Termination alone is, however, an inadequate endpoint for typical AFL ablation, where incomplete isthmus block leads to high recurrence rates. We assessed conduction block across a low lateral right atrial (RA) ablation line (LRA) from free wall scar to the inferior vena cava (IVC) or tricuspid annulus in 11 consecutive patients with atypical RA free wall flutter. LRA block was assessed following termination of AFL, by pacing from the ablation catheter in the low lateral RA posterior to the ablation line and recording the sequence and timing of activation anterior to the line with a duodecapole catheter, and vice versa for bidirectional block. LRA block resulted in a high to low activation pattern on the halo and a mean conduction time of 201 +/- 48 ms to distal halo. LRA conduction block was present in only 2 out of 6 patients after termination of AFL by ablation. Ablation was performed during sinus rhythm (SR) in 9 patients to achieve LRA conduction block. No recurrence of AFL was observed at long-term follow-up (22 +/- 12 months); 3 patients developed AF. Termination of right free wall flutter is often associated with persistent LRA conduction and additional radiofrequency ablation (RFA) in SR is usually required. Low RA pacing may be used to assess LRA conduction block and offers a robust endpoint for atypical RA free wall flutter ablation, which results in a high long-term cure rate.

  8. Relation of Obesity to New-Onset Atrial Fibrillation and Atrial Flutter in Adults.

    PubMed

    Foy, Andrew J; Mandrola, John; Liu, Guodong; Naccarelli, Gerald V

    2018-05-01

    Prospective cohort studies involving older adults report an association of obesity and new-onset atrial fibrillation and atrial flutter. To assess this relation, we performed a longitudinal cohort study from January 1, 2006 to December 31, 2013, using a national claims database that tracks all inpatient, outpatient, and pharmacy claims data. The primary end point of new-onset atrial fibrillation was compared between obese and nonobese cohorts. We used logistic regression to determine the strength of association between obesity and new-onset atrial fibrillation controlling for age, gender, hypertension, and diabetes. Overall, 67,278 subjects were included in the cohort, divided evenly between those with and without a diagnosis of obesity. Obese subjects were significantly more likely to have hypertension (29.5% vs 14.6%) and diabetes (12.7% vs 5.2%) at study onset. Over 8 years of follow-up, we recorded a new diagnosis of atrial fibrillation in 1,511 (2.2%) subjects. Obesity was strongly associated with a new diagnosis of atrial fibrillation after controlling for age, gender, hypertension, and diabetes (odds ratio 1.4, 95% confidence interval 1.3 to 1.6). In conclusion, this information contributes to the growing evidence supporting the causal relation between obesity and atrial fibrillation, and emphasizes the need of addressing obesity as part of our therapeutic strategy to prevent atrial fibrillation. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Revelation of changing axis deviation at the end of atrial fibrillation during acute myocardial infarction.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2011-05-19

    It has been rarely reported changing axis deviation also during atrial fibrillation or atrial flutter. Changing axis deviation has been also rarely reported during acute myocardial infarction associated with atrial fibrillation too. We present a case of a 49-year-old Italian man with revelation of changing axis deviation at the end of atrial fibrillation during acute myocardial infarction. Also this case focuses attention on changing axis deviation. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  10. Effect of high doses of magnesium on converting ibutilide to a safe and more effective agent.

    PubMed

    Patsilinakos, Sotirios; Christou, Apostolos; Kafkas, Nikolaos; Nikolaou, Nikolaos; Antonatos, Dionysios; Katsanos, Spyridon; Spanodimos, Stavros; Babalis, Dimitrios

    2010-09-01

    Ibutilide is a class III antiarrhythmic agent indicated for cardioversion of atrial fibrillation and atrial flutter to sinus rhythm (SR). The most serious complication of ibutilide is torsades de pointes (TdP). Magnesium has been successfully used for the treatment of TdP, but its use as a prophylactic agent for this arrhythmia has not yet been established. The present study investigated whether high dose of magnesium would increase the safety and efficacy of ibutilide administration. A total of 476 patients with atrial fibrillation or atrial flutter who were candidates for conversion to SR were divided into 2 groups. Group A consisted of 229 patients who received ibutilide to convert atrial fibrillation or atrial flutter to SR. Group B consisted of 247 patients who received an intravenous infusion of 5 g of magnesium sulfate for 1 hour followed by the administration of ibutilide. Then, another 5 g of magnesium were infused for 2 additional hours. Of the patients in groups A and B, 154 (67.3%) and 189 (76.5%), respectively, were converted to SR (p = 0.033). Ventricular arrhythmias (sustained, nonsustained ventricular tachycardia, and TdP) occurred significantly more often in group A than in group B (7.4% vs 1.2%, respectively, p = 0.002). TdP developed in 8 patients (3.5%) in group A and in none (0%) in group B (p = 0.009). The administration of magnesium (despite the high doses used) was well tolerated. In conclusion, the administration of high doses of magnesium probably makes ibutilide a much safer agent, and magnesium increased the conversion efficacy of ibutilide. 2010 Elsevier Inc. All rights reserved.

  11. Predictors of sick sinus syndrome in patients after successful radiofrequency catheter ablation of atrial flutter.

    PubMed

    Song, Changho; Jin, Moo-Nyun; Lee, Jung-Hee; Kim, In-Soo; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Joung, Boyoung

    2015-01-01

    The identification of sick sinus syndrome (SSS) in patients with atrial flutter (AFL) is difficult before the termination of AFL. This study investigated the patient characteristics used in predicting a high risk of SSS after AFL ablation. Out of 339 consecutive patients who had undergone radiofrequency ablation for AFL from 1991 to 2012, 27 (8%) had SSS (SSS group). We compared the clinical characteristics of patients with and without SSS (n=312, no-SSS group). The SSS group was more likely to have a lower body mass index (SSS: 22.5±3.2; no-SSS: 24.0±3.0 kg/m²; p=0.02), a history of atrial septal defects (ASD; SSS: 19%; no-SSS: 6%; p=0.01), a history of coronary artery bypass graft surgery (CABG; SSS: 11%; no-SSS: 2%; p=0.002), and a longer flutter cycle length (CL; SSS: 262.3±39.2; no-SSS: 243.0±40; p=0.02) than the no-SSS group. In multivariate analysis, a history of ASD [odds ratio (OR) 3.7, 95% confidence interval (CI) 1.2-11.4, p=0.02] and CABG (7.1, 95% CI 1.5-32.8, p=0.01) as well as longer flutter CL (1.1, 95% CI 1.0-1.2, p=0.04) were independent risk factors for SSS. A history of ASD and CABG as well as longer flutter CL increased the risk of SSS after AFL ablation. While half of the patients with SSS after AFL ablation experienced transient SSS, heart failure was associated with irreversible SSS.

  12. Predictors of Sick Sinus Syndrome in Patients after Successful Radiofrequency Catheter Ablation of Atrial Flutter

    PubMed Central

    Song, Changho; Jin, Moo-Nyun; Lee, Jung-Hee; Kim, In-Soo; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung

    2015-01-01

    Purpose The identification of sick sinus syndrome (SSS) in patients with atrial flutter (AFL) is difficult before the termination of AFL. This study investigated the patient characteristics used in predicting a high risk of SSS after AFL ablation. Materials and Methods Out of 339 consecutive patients who had undergone radiofrequency ablation for AFL from 1991 to 2012, 27 (8%) had SSS (SSS group). We compared the clinical characteristics of patients with and without SSS (n=312, no-SSS group). Results The SSS group was more likely to have a lower body mass index (SSS: 22.5±3.2; no-SSS: 24.0±3.0 kg/m2; p=0.02), a history of atrial septal defects (ASD; SSS: 19%; no-SSS: 6%; p=0.01), a history of coronary artery bypass graft surgery (CABG; SSS: 11%; no-SSS: 2%; p=0.002), and a longer flutter cycle length (CL; SSS: 262.3±39.2; no-SSS: 243.0±40; p=0.02) than the no-SSS group. In multivariate analysis, a history of ASD [odds ratio (OR) 3.7, 95% confidence interval (CI) 1.2-11.4, p=0.02] and CABG (7.1, 95% CI 1.5-32.8, p=0.01) as well as longer flutter CL (1.1, 95% CI 1.0-1.2, p=0.04) were independent risk factors for SSS. Conclusion A history of ASD and CABG as well as longer flutter CL increased the risk of SSS after AFL ablation. While half of the patients with SSS after AFL ablation experienced transient SSS, heart failure was associated with irreversible SSS. PMID:25510744

  13. Different mechanisms for diastolic mitral regurgitation illustrated by three comparative cases.

    PubMed

    Sisu, Roxana C; Vinereanu, Dragos

    2011-04-01

    Diastolic mitral regurgitation (DMR) has been reported in patients with AV block, aortic regurgitation, cardiomyopathies, and in patients with long filling periods in atrial tachyarrhythmias. The mechanism for DMR is a reversal in the atrioventricular gradient during diastole. However, because of its relatively low velocity, it may be difficult to diagnose noninvasively. We present three different cases of diastolic MR in 2:1 second-degree AV block, atrial flutter, and dilated cardiomyopathy, with different locations in diastole. Diastolic tricuspid regurgitation commonly accompanies DMR. Careful analysis of echocardiographical images related with online ECG is very important in order to delineate systolic and DMR, and their timing in systole and diastole. © 2011, Wiley Periodicals, Inc.

  14. Hybrid Therapy in the Management of Atrial Fibrillation

    PubMed Central

    Stárek, Zdeněk; Lehar, František; Jež, Jiří; Wolf, Jiří; Novák, Miroslav

    2015-01-01

    Atrial fibrillation is the most common sustained arrhythmia. Because of the sub-optimal outcomes and associated risks of medical therapy as well as the recent advances in non-pharmacologic strategies, a multitude of combined (hybrid) algorithms have been introduced that improve efficacy of standalone therapies while maintaining a high safety profile. Antiarrhythmic administration enhances success rate of electrical cardioversion. Catheter ablation of antiarrhythmic drug-induced typical atrial flutter may prevent recurrent atrial fibrillation. Through simple ablation in the right atrium, suppression of atrial fibrillation may be achieved in patients with previously ineffective antiarrhythmic therapy. Efficacy of complex catheter ablation in the left atrium is improved with antiarrhythmic drugs. Catheter ablation followed by permanent pacemaker implantation is an effective and safe treatment option for selected patients. Additional strategies include pacing therapies such as atrial pacing with permanent pacemakers, preventive pacing algorithms, and/or implantable dual-chamber defibrillators are available. Modern hybrid strategies combining both epicardial and endocardial approaches in order to create a complex set of radiofrequency lesions in the left atrium have demonstrated a high rate of success and warrant further research. Hybrid therapy for atrial fibrillation reviews history of development of non-pharmacological treatment strategies and outlines avenues of ongoing research in this field. PMID:25028165

  15. Atrial fibrillation associated with exogenous subclinical hyperthyroidism, changing axis deviation, troponin-I positive and without acute coronary syndrome.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2011-08-04

    Changing axis deviation has been rarely reported also during atrial fibrillation or atrial flutter. Changing axis deviation has been also rarely reported during acute myocardial infarction associated with atrial fibrillation or at the end of atrial fibrillation during acute myocardial infarction. Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. It has also been reported that increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. Serum troponin-I is a sensitive indicator of myocardial damage but abnormal troponin-I levels have been also reported without acute coronary syndrome and without cardiac damage. Abnormal troponin-I levels after supraventricular tachycardia have been also reported. We present a case of changing axis deviation in a 49-year-old Italian man with atrial fibrillation, exogenous subclinical hyperthyroidism and troponin-I positive without acute coronary syndrome. Also this case focuses attention on changing axis deviation, on subclinical hyperthyroidism and on the importance of a correct evaluation of abnormal troponin-I levels. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  16. Atrial fibrillation associated with exogenous subclinical hyperthyroidism.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2010-11-19

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. It has also been reported that increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. Moreover acute myocardial infarction has been reported during L-thyroxine substitution therapy. Far more common and relatively less studied is exogenous subclinical hyperthyroidism caused by L-thyroxine administration to thyroidectomized or hypothyroid patients or patients with simple or nodular goiter. We present a case of atrial fibrillation associated with exogenous subclinical hyperthyroidism, in a 72-year-old Italian woman. Also this case focuses attention on the importance of a correct evaluation of subclinical hyperthyroidism. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Chronic nicotine in hearts with healed ventricular myocardial infarction promotes atrial flutter that resembles typical human atrial flutter.

    PubMed

    Miyauchi, Mizuho; Qu, Zhilin; Miyauchi, Yasushi; Zhou, Sheng-Mei; Pak, Hui; Mandel, William J; Fishbein, Michael C; Chen, Peng-Sheng; Karagueuzian, Hrayr S

    2005-06-01

    The potential of chronic nicotine exposure for atrial fibrillation (AF) and atrial flutter (AFL) in hearts with and without chronic myocardial infarction (MI) remains poorly explored. MI was created in dogs by permanent occlusion of the left anterior descending coronary artery, and dogs were administered nicotine (5 mg.kg(-1).day(-1) sc) for 1 mo using osmotic minipumps. High-resolution epicardial (1,792 bipolar electrodes) and endocardial Halo catheters were used to map activation during induced atrial rhythms. Nicotine promoted inducible sustained AFL at a mean cycle length of 134 +/- 10 ms in all MI dogs (n = 6) requiring pacing and electrical shocks for termination. No AFL could be induced in MI dogs (n = 6), control (non-MI) dogs (n = 3) not exposed to nicotine, and dogs with no MI and exposed to nicotine (n = 3). Activation maps during AFL showed a single reentrant wavefront in the right atrium that rotated either clockwise (60%) or counterclockwise (40%) around the crista terminalis and through the isthmus. Ablation of the isthmus prevented the induction of AFL. Nicotine caused a significant (P < 0.01) but highly heterogeneous increase in atrial interstitial fibrosis (2- to 10-fold increase in left and right atria, respectively) in the MI group but only a 2-fold increase in the right atrium in the non-MI group. Nicotine also flattened (P < 0.05) the slope of the epicardial monophasic action potential duration (electrical restitution) curve of both atria in the MI but not in non-MI dogs. Two-dimensional simulation in an excitable matrix containing an isthmus and nicotine's restitutional and reduced gap junctional coupling (fibrosis) parameters replicated the experiments. Chronic nicotine in hearts with MI promotes AFL that closely resembles typical human AFL. Increased atrial interstitial fibrosis and flattened electrical restitution are important substrates for the AFL.

  18. Incessant atrial tachycardias in a dog with tricuspid dysplasia. Clinical management and electrophysiology.

    PubMed

    de Madron, E; Kadish, A; Spear, J F; Knight, D H

    1987-01-01

    In a dog, tricuspid regurgitation due to congenital tricuspid dysplasia resulted in extreme right heart enlargement and right heart failure. Incessant supraventricular tachycardias were present, requiring the intravenous administration of verapamil to reduce the ventricular rate. Oral therapy using a combination of verapamil and quinidine was partially effective in controlling the ventricular rate during the following week. At that time, electrophysiologic studies were performed. They revealed that a succession of several atrial tachycardias with different cycle lengths, including one episode of atrial flutter, was present. Atrial activity was spanning the majority of the cycle length in all these arrhythmias. Epicardial mapping was performed during the atrial flutter. This enabled the detection of a depolarization wave-front traveling counterclockwise from the dorsolateral right atrium toward the right appendage, following the tricuspid valve annulus. No areas of abnormal conduction were detected. Because programmed electric stimulation maneuvers could not be performed, definitive conclusions about the mechanism of the arrhythmia could not be drawn. The two most likely possibilities were circus movement using part of the dilated tricuspid valve annulus as an anatomic barrier or a leading circle type of re-entry.

  19. Atrial Flutter

    MedlinePlus

    ... Certification (MOC) Scientific Sessions Certified Education Courses & Online Learning Co-Sponsored & Endorsed Events Educational Resources Career Resources Job Board Fellowships & Program Directors IBHRE Exam Jobs at ...

  20. Influence of Genotype on Structural Atrial Abnormalities and Atrial Fibrillation or Flutter in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    PubMed

    Bourfiss, Mimount; Te Riele, Anneline S J M; Mast, Thomas P; Cramer, Maarten J; VAN DER Heijden, Jeroen F; VAN Veen, Toon A B; Loh, Peter; Dooijes, Dennis; Hauer, Richard N W; Velthuis, Birgitta K

    2016-12-01

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is associated with desmosomal mutations. Although desmosomal disruption affects both ventricles and atria, little is known about atrial involvement in ARVD/C. To describe the extent and clinical significance of structural atrial involvement and atrial arrhythmias (AA) in ARVD/C stratified by genotype. We included 71 patients who met ARVD/C Task Force Criteria and underwent cardiac magnetic resonance (CMR) imaging and molecular genetic analysis. Indexed atrial end-diastolic volume and area-length-ejection-fraction (ALEF) were evaluated on CMR and compared to controls with idiopathic right ventricular outflow tract tachycardia (n = 40). The primary outcome was occurrence of AA (atrial fibrillation or atrial flutter) during follow-up, recorded by 12-lead ECG, Holter monitoring or implantable cardioverter defibrillator (ICD) interrogation. Patients harbored a desmosomal plakophilin-2 (PKP2) (n = 37) or nondesmosomal phospholamban (PLN) (n = 14) mutation. In 20 subjects, no pathogenic mutation was identified. Compared to controls, right atrial (RA) volumes were reduced in PKP2 (P = 0.002) and comparable in PLN (P = 0.441) mutation carriers. In patients with no mutation identified, RA (P = 0.011) and left atrial (P = 0.034) volumes were increased. Bi-atrial ALEF showed no significant difference between the groups. AA were experienced by 27% of patients and occurred equally among PKP2 (30%) and no mutation identified patients (30%), but less among PLN mutation carriers (14%). Genotype influences atrial volume and occurrence of AA in ARVD/C. While the incidence of AA is similar in PKP2 mutation carriers and patients with no mutation identified, PKP2 mutation carriers have significantly smaller atria. This suggests a different arrhythmogenic mechanism. © 2016 Wiley Periodicals, Inc.

  1. On-line telemetry: prospective assessment of accuracy in an all-volunteer emergency medical service system.

    PubMed

    Hollander, J E; Delagi, R; Sciammarella, J; Viccellio, P; Ortiz, J; Henry, M C

    1995-04-01

    To evaluate the need for on-line telemetry control in an all-volunteer, predominantly advanced emergency medical technician (A-EMT) ambulance system. Emergency medical service (EMS) advanced life support (ALS) providers were asked to transmit the ECG rhythms of monitored patients over a six-month period in 1993. The ECG rhythm interpretations of volunteer EMS personnel were compared with those of the on-line medical control physician. All discordant readings were reviewed by a panel of physicians to decide whether the misdiagnosis would have resulted in treatment aberrations had transmission been unavailable. Patients were monitored and rhythms were transmitted in 1,825 cases. 1,642 of 1,825 rhythms were correctly interpreted by the EMS providers (90%; 95% CI 89-91%). The accuracy of the EMS providers was dependent on the patient's rhythm (chi-square, p < 0.00001), the chief complaint (chi-square, p = 0.0001), and the provider's level of training (chi-square, p = 0.02). Correct ECG rhythm interpretations were more common when the out-of-hospital interpretation was sinus rhythm (95%), ventricular fibrillation (87%), paced rhythm (94%), or agonal rhythm (96%). The EMS providers were frequently incorrect when the out-of-hospital rhythm interpretation was atrial fibrillation/flutter (71%), supraventricular tachycardia (46%), ventricular tachycardia (59%), or atrioventricular block (50%). Of the 183 discordant cases, 124 (68%) involved missing a diagnosis of, or incorrectly diagnosing, atrial fibrillation/flutter. Review of the discordant readings identified 11 cases that could have resulted in treatment errors had the rhythms not been transmitted, one of which might have resulted in an adverse outcome. In this all-volunteer, predominantly A-EMT ALS system, patients with a field interpretation of a sinus rhythm do not require ECG rhythm transmission. Field interpretations of atrial fibrillation/flutter, supraventricular tachycardia, ventricular tachycardia, and atrioventricular blocks are frequently incorrect and should continue to be transmitted.

  2. Efficacy comparison between cryoablation and radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter: a meta-analysis

    NASA Astrophysics Data System (ADS)

    Chen, Yi-He; Lin, Hui; Xie, Cheng-Long; Zhang, Xiao-Ting; Li, Yi-Gang

    2015-06-01

    We perform this meta-analysis to compare the efficacy and safety of cryoablation versus radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter. By searching EMBASE, MEDLINE, PubMed and Cochrane electronic databases from March 1986 to September 2014, 7 randomized clinical trials were included. Acute (risk ratio[RR]: 0.93; P = 0.14) and long-term (RR: 0.94; P = 0.08) success rate were slightly lower in cryoablation group than in radiofrequency ablation group, but the difference was not statistically significant. Additionally, the fluoroscopy time was nonsignificantly reduced (weighted mean difference[WMD]: -2.83 P = 0.29), whereas procedure time was significantly longer (WMD: 25.95; P = 0.01) in cryoablation group compared with radiofrequency ablation group. Furthermore, Pain perception during the catheter ablation was substantially less in cryoabaltion group than in radiofrequency ablation group (standardized mean difference[SMD]: -2.36 P < 0.00001). Thus, our meta-analysis demonstrated that cryoablation and radiofrequency ablation produce comparable acute and long-term success rate for patients with cavotricuspid valve isthmus dependent atrial flutter. Meanwhile, cryoablation ablation tends to reduce the fluoroscopy time and significantly reduce pain perception in cost of significantly prolonged procedure time.

  3. Efficacy comparison between cryoablation and radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter: a meta-analysis

    PubMed Central

    Chen, Yi-He; Lin, Hui; Xie, Cheng-Long; Zhang, Xiao-Ting; Li, Yi-Gang

    2015-01-01

    We perform this meta-analysis to compare the efficacy and safety of cryoablation versus radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter. By searching EMBASE, MEDLINE, PubMed and Cochrane electronic databases from March 1986 to September 2014, 7 randomized clinical trials were included. Acute (risk ratio[RR]: 0.93; P = 0.14) and long-term (RR: 0.94; P = 0.08) success rate were slightly lower in cryoablation group than in radiofrequency ablation group, but the difference was not statistically significant. Additionally, the fluoroscopy time was nonsignificantly reduced (weighted mean difference[WMD]: −2.83; P = 0.29), whereas procedure time was significantly longer (WMD: 25.95; P = 0.01) in cryoablation group compared with radiofrequency ablation group. Furthermore, Pain perception during the catheter ablation was substantially less in cryoabaltion group than in radiofrequency ablation group (standardized mean difference[SMD]: −2.36; P < 0.00001). Thus, our meta-analysis demonstrated that cryoablation and radiofrequency ablation produce comparable acute and long-term success rate for patients with cavotricuspid valve isthmus dependent atrial flutter. Meanwhile, cryoablation ablation tends to reduce the fluoroscopy time and significantly reduce pain perception in cost of significantly prolonged procedure time. PMID:26039980

  4. The novel antiarrhythmic drug dronedarone: comparison with amiodarone.

    PubMed

    Kathofer, Sven; Thomas, Dierk; Karle, Christoph A

    2005-01-01

    Dronedarone is a noniodinated benzofuran derivative that has been developed to overcome the limiting iodine-associated adverse effects of the commonly used antiarrhythmic drug, amiodarone. It displays a wide cellular electrophysiological spectrum largely similar to amiodarone, inhibiting the potassium currents I(Kr), I(Ks), I(KI), I(KACh), and I(sus), as well as sodium currents and L-type calcium currents in isolated cardiomyocytes. In addition, dronedarone exhibits antiadrenergic properties. In vivo, dronedarone has been shown to be more effective than amiodarone in several arrhythmia models, particularly in preventing ischemia- and reperfusion-induced ventricular fibrillation and in reducing mortality. However, an increased incidence of torsades de pointes with dronedarone in dogs shows that possible proarrhythmic effects of dronedarone require further evaluation. The clinical trails DAFNE, EURIDIS, and ADONIS indicated safety, antiarrhythmic efficacy and low proarrhythmic potential of the drug in low-risk patients. In contrast, the increased incidence of death in the dronedarone group of the discontinued ANDROMEDA trial raises safety concerns for patients with congestive heart failure and moderate to severe left ventricular dysfunction. Dronedarone appears to be effective in preventing relapses of atrial fibrillation and atrial flutter. Torsades de pointes, the most severe adverse effect associated with amiodarone, has not yet been reported in humans with dronedarone. Unlike amiodarone, dronedarone had little effect on thyroid function and hormone levels in animal models and had no significant effects on human thyroid function in clinical trials. In conclusion, dronedarone could be a useful drug for prevention of atrial fibrillation and atrial flutter relapses in low-risk patients. However, further experimental studies and long-term clinical trials are required to provide additional evidence of efficacy and safety of dronedarone.

  5. Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of paroxysmal atrial fibrillation (RAAFT-2): a randomized trial.

    PubMed

    Morillo, Carlos A; Verma, Atul; Connolly, Stuart J; Kuck, Karl H; Nair, Girish M; Champagne, Jean; Sterns, Laurence D; Beresh, Heather; Healey, Jeffrey S; Natale, Andrea

    2014-02-19

    Atrial fibrillation (AF) is the most common rhythm disorder seen in clinical practice. Antiarrhythmic drugs are effective for reduction of recurrence in patients with symptomatic paroxysmal AF. Radiofrequency ablation is an accepted therapy in patients for whom antiarrhythmic drugs have failed; however, its role as a first-line therapy needs further investigation. To compare radiofrequency ablation with antiarrhythmic drugs (standard therapy) in treating patients with paroxysmal AF as a first-line therapy. A randomized clinical trial involving 127 treatment-naive patients with paroxysmal AF were randomized at 16 centers in Europe and North America to received either antiarrhythmic therapy or ablation. The first patient was enrolled July 27, 2006; the last patient, January 29, 2010. The last follow-up was February 16, 2012. Sixty-one patients in the antiarrhythmic drug group and 66 in the radiofrequency ablation group were followed up for 24 months. The time to the first documented atrial tachyarrhythmia of more than 30 seconds (symptomatic or asymptomatic AF, atrial flutter, or atrial tachycardia), detected by either scheduled or unscheduled electrocardiogram, Holter, transtelephonic monitor, or rhythm strip, was the primary outcome. Secondary outcomes included symptomatic recurrences of atrial tachyarrhythmias and quality of life measures assessed by the EQ-5D tool. Forty-four patients (72.1%) in the antiarrhythmic group and in 36 patients (54.5%) in the ablation group experienced the primary efficacy outcome (hazard ratio [HR], 0.56 [95% CI, 0.35-0.90]; P = .02). For the secondary outcomes, 59% in the drug group and 47% in the ablation group experienced the first recurrence of symptomatic AF, atrial flutter, atrial tachycardia (HR, 0.56 [95% CI, 0.33-0.95]; P = .03). No deaths or strokes were reported in either group; 4 cases of cardiac tamponade were reported in the ablation group. In the standard treatment group, 26 patients (43%) underwent ablation after 1-year. Quality of life was moderately impaired at baseline in both groups and improved at the 1 year follow-up. However, improvement was not significantly different among groups. Among patients with paroxysmal AF without previous antiarrhythmic drug treatment, radiofrequency ablation compared with antiarrhythmic drugs resulted in a lower rate of recurrent atrial tachyarrhythmias at 2 years. However, recurrence was frequent in both groups. clinicaltrials.gov Identifier: NCT00392054.

  6. A genotype-directed comparative effectiveness trial of Bucindolol and metoprolol succinate for prevention of symptomatic atrial fibrillation/atrial flutter in patients with heart failure: Rationale and design of the GENETIC-AF trial.

    PubMed

    Piccini, Jonathan P; Connolly, Stuart J; Abraham, William T; Healey, Jeff S; Steinberg, Benjamin A; Al-Khalidi, Hussein R; Dignacco, Patricia; van Veldhuisen, Dirk J; Sauer, William H; White, Michel; Wilton, Stephen B; Anand, Inder S; Dufton, Christopher; Marshall, Debra A; Aleong, Ryan G; Davis, Gordon W; Clark, Richard L; Emery, Laura L; Bristow, Michael R

    2018-05-01

    Few therapies are available for the safe and effective treatment of atrial fibrillation (AF) in patients with heart failure. Bucindolol is a non-selective beta-blocker with mild vasodilator activity previously found to have accentuated antiarrhythmic effects and increased efficacy for preventing heart failure events in patients homozygous for the major allele of the ADRB1 Arg389Gly polymorphism (ADRB1 Arg389Arg genotype). The safety and efficacy of bucindolol for the prevention of AF or atrial flutter (AFL) in these patients has not been proven in randomized trials. The Genotype-Directed Comparative Effectiveness Trial of Bucindolol and Metoprolol Succinate for Prevention of Symptomatic Atrial Fibrillation/Atrial Flutter in Patients with Heart Failure (GENETIC-AF) trial is a multicenter, randomized, double-blinded "seamless" phase 2B/3 trial of bucindolol hydrochloride versus metoprolol succinate, for the prevention of symptomatic AF/AFL in patients with reduced ejection fraction heart failure (HFrEF). Patients with pre-existing HFrEF and recent history of symptomatic AF are eligible for enrollment and genotype screening, and if they are ADRB1 Arg389Arg, eligible for randomization. A total of approximately 200 patients will comprise the phase 2B component and if pre-trial assumptions are met, 620 patients will be randomized at approximately 135 sites to form the Phase 3 population. The primary endpoint is the time to recurrence of symptomatic AF/AFL or mortality over a 24-week follow-up period, and the trial will continue until 330 primary endpoints have occurred. GENETIC-AF is the first randomized trial of pharmacogenetic guided rhythm control, and will test the safety and efficacy of bucindolol compared with metoprolol succinate for the prevention of recurrent symptomatic AF/AFL in patients with HFrEF and an ADRB1 Arg389Arg genotype. (ClinicalTrials.govNCT01970501). Copyright © 2017 Elsevier Inc. All rights reserved.

  7. The benefit of tissue contact monitoring with an electrical coupling index during ablation of typical atrial flutter--a prospective randomised control trial.

    PubMed

    Jones, Michael A; Webster, David; Wong, Kelvin C K; Hayes, Christopher; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R

    2014-12-01

    We sought to investigate the use of tissue contact monitoring by means of the electrical coupling index (ECI) in a prospective randomised control trial of patients undergoing cavotricuspid isthmus (CTI) ablation for atrial flutter. Patients with ECG-documented typical flutter undergoing their first CTI ablation were randomised to ECI™-guided or non-ECI™-guided ablation. An irrigated-tip ablation catheter was used in all cases. Consecutive 50-W, 60-s radiofrequency lesions were applied to the CTI, from the tricuspid valve to inferior vena cava, with no catheter movement permitted during radiofrequency (RF) delivery. The ablation endpoint was durable CTI block at 20 min post-ablation. Patients underwent routine clinic follow-up post-operatively. A total of 101 patients (79 male), mean age 66 (+/-11), 50 ECI-guided and 51 control cases were enrolled in the study. CTI block was achieved in all. There were no acute complications. All patients were alive at follow-up. CTI block was achieved in a single pass in 36 ECI-guided and 30 control cases (p = 0.16), and at 20 min post-ablation, re-conduction was seen in 5 and 12 cases, respectively (p = 0.07). There was no significant difference in total procedure time (62.7 ± 33 vs. 62.3 ± 33 min, p = 0.92), RF requirement (580 ± 312 vs. 574 ± 287 s, p = 0.11) or fluoroscopy time (718 ± 577 vs. 721 ± 583 s, p = 0.78). After 6 ± 4 months, recurrence of flutter had occurred in 1 (2 %) ECI vs. 8 (16 %) control cases (OR 0.13, 95 % CI 0.01-1.08, p = 0.06). ECI-guided CTI ablation demonstrated a non-statistically significant reduction in late recurrence of atrial flutter, at no cost to procedural time, radiation exposure or RF requirement.

  8. Atrial and ventricular tachyarrhythmias in military personnel.

    PubMed

    Posselt, Bonnie N; Cox, A T; D'Arcy, J; Rooms, M; Saba, M

    2015-09-01

    Although rare, sudden cardiac death does occur in British military personnel. In the majority of cases, the cause is considered to be a malignant ventricular tachyarrhythmia, which can be precipitated by a number of underlying pathologies. Conversely, a tachyarrhythmia may have a more benign and treatable cause, yet the initial clinical symptoms may be similar, making differentiation difficult. This is an overview of the mechanisms underlying the initiation and propagation of arrhythmias and the various pathological conditions that predispose to arrhythmia genesis, classified according to which parts of the heart are involved: atrial tachyarrhythmias, atrial and ventricular, as well as those affecting the ventricles alone. It encompasses atrial tachycardia, atrial flutter, supraventricular tachycardias and ventricular tachycardias, including the more commonly encountered inherited primary electrical diseases, also known as the channelopathies. The clinical features, investigation and management strategies are outlined. The occupational impact-in serving military personnel and potential recruits-is described, with explanations relating to the different conditions and their specific implication on continued military service. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

    NASA Technical Reports Server (NTRS)

    Jaber, W. A.; Prior, D. L.; Thamilarasan, M.; Grimm, R. A.; Thomas, J. D.; Klein, A. L.; Asher, C. R.

    2000-01-01

    BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

  10. The effects of rhythm control strategies versus rate control strategies for atrial fibrillation and atrial flutter: A systematic review with meta-analysis and Trial Sequential Analysis

    PubMed Central

    Gluud, Christian; Jakobsen, Janus C.

    2017-01-01

    Background Atrial fibrillation and atrial flutter may be managed by either a rhythm control strategy or a rate control strategy but the evidence on the clinical effects of these two intervention strategies is unclear. Our objective was to assess the beneficial and harmful effects of rhythm control strategies versus rate control strategies for atrial fibrillation and atrial flutter. Methods We searched CENTRAL, MEDLINE, Embase, LILACS, Web of Science, BIOSIS, Google Scholar, clinicaltrials.gov, TRIP, EU-CTR, Chi-CTR, and ICTRP for eligible trials comparing any rhythm control strategy with any rate control strategy in patients with atrial fibrillation or atrial flutter published before November 2016. Our primary outcomes were all-cause mortality, serious adverse events, and quality of life. Our secondary outcomes were stroke and ejection fraction. We performed both random-effects and fixed-effect meta-analysis and chose the most conservative result as our primary result. We used Trial Sequential Analysis (TSA) to control for random errors. Statistical heterogeneity was assessed by visual inspection of forest plots and by calculating inconsistency (I2) for traditional meta-analyses and diversity (D2) for TSA. Sensitivity analyses and subgroup analyses were conducted to explore the reasons for substantial statistical heterogeneity. We assessed the risk of publication bias in meta-analyses consisting of 10 trials or more with tests for funnel plot asymmetry. We used GRADE to assess the quality of the body of evidence. Results 25 randomized clinical trials (n = 9354 participants) were included, all of which were at high risk of bias. Meta-analysis showed that rhythm control strategies versus rate control strategies significantly increased the risk of a serious adverse event (risk ratio (RR), 1.10; 95% confidence interval (CI), 1.02 to 1.18; P = 0.02; I2 = 12% (95% CI 0.00 to 0.32); 21 trials), but TSA did not confirm this result (TSA-adjusted CI 0.99 to 1.22). The increased risk of a serious adverse event did not seem to be caused by any single component of the composite outcome. Meta-analysis showed that rhythm control strategies versus rate control strategies were associated with better SF-36 physical component score (mean difference (MD), 6.93 points; 95% CI, 2.25 to 11.61; P = 0.004; I2 = 95% (95% CI 0.94 to 0.96); 8 trials) and ejection fraction (MD, 4.20%; 95% CI, 0.54 to 7.87; P = 0.02; I2 = 79% (95% CI 0.69 to 0.85); 7 trials), but TSA did not confirm these results. Both meta-analysis and TSA showed no significant differences on all-cause mortality, SF-36 mental component score, Minnesota Living with Heart Failure Questionnaire, and stroke. Conclusions Rhythm control strategies compared with rate control strategies seem to significantly increase the risk of a serious adverse event in patients with atrial fibrillation. Based on current evidence, it seems that most patients with atrial fibrillation should be treated with a rate control strategy unless there are specific reasons (e.g., patients with unbearable symptoms due to atrial fibrillation or patients who are hemodynamically unstable due to atrial fibrillation) justifying a rhythm control strategy. More randomized trials at low risk of bias and low risk of random errors are needed. Trial registration PROSPERO CRD42016051433 PMID:29073191

  11. Atrial fibrillation associated with chocolate intake abuse and chronic salbutamol inhalation abuse.

    PubMed

    Patanè, Salvatore; Marte, Filippo; La Rosa, Felice Carmelo; Rocca, Roberto La

    2010-11-19

    The use of substances as the substrate for atrial fibrillation is not frequently recognized. Chocolate is derived from the roasted seeds of the plant theobroma cacao and its components are the methylxanthine alkaloids theobromine and caffeine. Caffeine is a methylxanthine whose primary biological effect is the competitive antagonism of the adenosine receptor. Normal consumption of caffeine was not associated with risk of atrial fibrillation or flutter. Sympathomimetic effects, due to circulating catecholamines cause the cardiac manifestations of caffeine overdose toxicity, produce tachyarrhythmias such as supraventricular tachycardia, atrial fibrillation, ventricular tachycardia, and ventricular fibrillation.The commonly used doses of inhaled or nebulized salbutamol induced no acute myocardial ischaemia, arrhythmias or changes in heart rate variability in patients with coronary artery disease and clinically stable asthma or chronic obstructive pulmonary disease. Two-week salbutamol treatment shifts the cardiovascular autonomic regulation to a new level characterized by greater sympathetic responsiveness and slight beta2-receptor tolerance. We present a case of atrial fibrillation associated with chocolate intake abuse in a 19-year-old Italian woman with chronic salbutamol inhalation abuse. This case focuses attention on chocolate intake abuse associated with chronic salbutamol abuse as the substrate for atrial fibrillation. Copyright © 2008 Elsevier Ireland Ltd. All rights reserved.

  12. A Three-Dimensional Human Atrial Model with Fiber Orientation. Electrograms and Arrhythmic Activation Patterns Relationship

    PubMed Central

    Tobón, Catalina; Ruiz-Villa, Carlos A.; Heidenreich, Elvio; Romero, Lucia; Hornero, Fernando; Saiz, Javier

    2013-01-01

    The most common sustained cardiac arrhythmias in humans are atrial tachyarrhythmias, mainly atrial fibrillation. Areas of complex fractionated atrial electrograms and high dominant frequency have been proposed as critical regions for maintaining atrial fibrillation; however, there is a paucity of data on the relationship between the characteristics of electrograms and the propagation pattern underlying them. In this study, a realistic 3D computer model of the human atria has been developed to investigate this relationship. The model includes a realistic geometry with fiber orientation, anisotropic conductivity and electrophysiological heterogeneity. We simulated different tachyarrhythmic episodes applying both transient and continuous ectopic activity. Electrograms and their dominant frequency and organization index values were calculated over the entire atrial surface. Our simulations show electrograms with simple potentials, with little or no cycle length variations, narrow frequency peaks and high organization index values during stable and regular activity as the observed in atrial flutter, atrial tachycardia (except in areas of conduction block) and in areas closer to ectopic activity during focal atrial fibrillation. By contrast, cycle length variations and polymorphic electrograms with single, double and fragmented potentials were observed in areas of irregular and unstable activity during atrial fibrillation episodes. Our results also show: 1) electrograms with potentials without negative deflection related to spiral or curved wavefronts that pass over the recording point and move away, 2) potentials with a much greater proportion of positive deflection than negative in areas of wave collisions, 3) double potentials related with wave fragmentations or blocking lines and 4) fragmented electrograms associated with pivot points. Our model is the first human atrial model with realistic fiber orientation used to investigate the relationship between different atrial arrhythmic propagation patterns and the electrograms observed at more than 43000 points on the atrial surface. PMID:23408928

  13. Analysis of antithrombotic therapy after cardioembolic stroke due to atrial fibrillation or flutter.

    PubMed

    Peterson, Evan J; Reaves, Anne B; Smith, Jennifer L; Oliphant, Carrie S

    2013-02-01

    Guidelines recommend that all patients with atrial fibrillation and a history of ischemic stroke should receive an anticoagulant. Prior analyses show that warfarin is underutilized in most populations. To examine the use of antithrombotic and anticoagulant therapy in patients with atrial fibrillation or flutter during the index hospitalization for acute, ischemic stroke. Retrospective electronic medical record review of 200 patients treated at a tertiary care hospital with a primary ICD-9 code for ischemic stroke and a secondary ICD-9 code for atrial fibrillation or flutter. Exclusion criteria were active bleeding, pregnancy, age less than 18, pre-existing warfarin allergy, or dabigatran use. Fifty-two percent of patients received at least one dose of warfarin during the index hospitalization. There was no relationship between CHADS2 score and likelihood of receiving warfarin (P > .05). There was no significant difference in adverse event rate in patients receiving warfarin compared to those receiving aspirin (3.8% vs 9.1%; P = .14), but the rate of hemorrhagic transformation was lower in patients receiving warfarin (1% vs 7%; P = .03). The composite of hemorrhagic stroke or hemorrhagic transformation was significantly lower in patients receiving bridging therapy (0% vs 11%; P = .03). Sixteen patients were readmitted for stroke within 3 months of discharge. Ten were readmitted for ischemic stroke, 3 for hemorrhagic stroke or hemorrhagic transformation, and 3 for systemic bleeding. Ten patients (62.5%) were receiving warfarin at readmission, but only one of these patients had a therapeutic INR. Warfarin was underutilized as secondary stroke prophylaxis in these high-risk patients. Bridging therapy appeared to be safe and was not associated with an increase in adverse events.

  14. First experience with zero-fluoroscopic ablation for supraventricular tachycardias using a novel impedance and magnetic-field-based mapping system.

    PubMed

    Walsh, Katie A; Galvin, Joseph; Keaney, John; Keelan, Edward; Szeplaki, Gabor

    2018-02-23

    Zero- and near-zero-fluoroscopic ablation techniques reduce the harmful effects of ionizing radiation during invasive electrophysiology procedures. We aimed to test the feasibility and safety of a zero-fluoroscopic strategy using a novel integrated magnetic and impedance-based electroanatomical mapping system for radiofrequency ablation (RFA) of supraventricular tachycardias (SVTs). We retrospectively studied 92 consecutive patients undergoing electrophysiology studies with/without RFA for supraventricular tachycardia (SVT) performed by a single operator at a single center. The first 42 (Group 1) underwent a conventional fluoroscopic-guided approach and the second 50 (Group 2) underwent a zero-fluoroscopic approach using the Ensite Precision ™ 3-D magnetic and impedance-based mapping system (Abbott Inc). Group 1 comprised 14 AV-nodal re-entrant tachycardia (AVNRT), 12 typical atrial flutter, 4 accessory pathway (AP), 2 atrial tachycardia (AT), and 9 diagnostic EP studies (EPS). Group 2 comprised 16 AVNRT, 17 atrial flutter, 6 AP, 3 AT, 2 AV-nodal ablations, and 7 EPS. A complete zero-fluoroscopic approach was achieved in 94% of Group 2 patients. All procedures were acutely successful, and no complications occurred. There was a significant reduction in fluoroscopy dose, dose area product, and time (p < 0.0001, for all), with no difference in procedure times. Ablation time for typical atrial flutter was shorter in Group 2 (p = 0.006). A zero-fluoroscopic strategy for diagnosis and treatment of SVTs using this novel 3D-electroanatomical mapping system is feasible in majority of patients, is safe, reduces ionizing radiation exposure, and does not compromise procedural times, success rates, or complication rates.

  15. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    PubMed Central

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  16. Accurate ECG diagnosis of atrial tachyarrhythmias using quantitative analysis: a prospective diagnostic and cost-effectiveness study.

    PubMed

    Krummen, David E; Patel, Mitul; Nguyen, Hong; Ho, Gordon; Kazi, Dhruv S; Clopton, Paul; Holland, Marian C; Greenberg, Scott L; Feld, Gregory K; Faddis, Mitchell N; Narayan, Sanjiv M

    2010-11-01

    Quantitative ECG Analysis. Optimal atrial tachyarrhythmia management is facilitated by accurate electrocardiogram interpretation, yet typical atrial flutter (AFl) may present without sawtooth F-waves or RR regularity, and atrial fibrillation (AF) may be difficult to separate from atypical AFl or rapid focal atrial tachycardia (AT). We analyzed whether improved diagnostic accuracy using a validated analysis tool significantly impacts costs and patient care. We performed a prospective, blinded, multicenter study using a novel quantitative computerized algorithm to identify atrial tachyarrhythmia mechanism from the surface ECG in patients referred for electrophysiology study (EPS). In 122 consecutive patients (age 60 ± 12 years) referred for EPS, 91 sustained atrial tachyarrhythmias were studied. ECGs were also interpreted by 9 physicians from 3 specialties for comparison and to allow healthcare system modeling. Diagnostic accuracy was compared to the diagnosis at EPS. A Markov model was used to estimate the impact of improved arrhythmia diagnosis. We found 13% of typical AFl ECGs had neither sawtooth flutter waves nor RR regularity, and were misdiagnosed by the majority of clinicians (0/6 correctly diagnosed by consensus visual interpretation) but correctly by quantitative analysis in 83% (5/6, P = 0.03). AF diagnosis was also improved through use of the algorithm (92%) versus visual interpretation (primary care: 76%, P < 0.01). Economically, we found that these improvements in diagnostic accuracy resulted in an average cost-savings of $1,303 and 0.007 quality-adjusted-life-years per patient. Typical AFl and AF are frequently misdiagnosed using visual criteria. Quantitative analysis improves diagnostic accuracy and results in improved healthcare costs and patient outcomes. © 2010 Wiley Periodicals, Inc.

  17. Thromboprophylaxis for Patients with High-risk Atrial Fibrillation and Flutter Discharged from the Emergency Department.

    PubMed

    Vinson, David R; Warton, E Margaret; Mark, Dustin G; Ballard, Dustin W; Reed, Mary E; Chettipally, Uli K; Singh, Nimmie; Bouvet, Sean Z; Kea, Bory; Ramos, Patricia C; Glaser, David S; Go, Alan S

    2018-03-01

    Many patients with atrial fibrillation or atrial flutter (AF/FL) who are high risk for ischemic stroke are not receiving evidence-based thromboprophylaxis. We examined anticoagulant prescribing within 30 days of receiving dysrhythmia care for non-valvular AF/FL in the emergency department (ED). This prospective study included non-anticoagulated adults at high risk for ischemic stroke (ATRIA score ≥7) who received emergency AF/FL care and were discharged home from seven community EDs between May 2011 and August 2012. We characterized oral anticoagulant prescribing patterns and identified predictors of receiving anticoagulants within 30 days of the index ED visit. We also describe documented reasons for withholding anticoagulation. Of 312 eligible patients, 128 (41.0%) were prescribed anticoagulation at ED discharge or within 30 days. Independent predictors of anticoagulation included age (adjusted odds ratio [aOR] 0.89 per year, 95% confidence interval [CI] 0.82-0.96); ED cardiology consultation (aOR 1.89, 95% CI [1.10-3.23]); and failure of sinus restoration by time of ED discharge (aOR 2.65, 95% CI [1.35-5.21]). Reasons for withholding anticoagulation at ED discharge were documented in 139 of 227 cases (61.2%), the most common of which were deferring the shared decision-making process to the patient's outpatient provider, perceived bleeding risk, patient refusal, and restoration of sinus rhythm. Approximately 40% of non-anticoagulated AF/FL patients at high risk for stroke who presented for emergency dysrhythmia care were prescribed anticoagulation within 30 days. Physicians were less likely to anticoagulate older patients and those with ED sinus restoration. Opportunities exist to improve rates of thromboprophylaxis in this high-risk population.

  18. Digoxin for atrial fibrillation and atrial flutter: A systematic review with meta-analysis and trial sequential analysis of randomised clinical trials

    PubMed Central

    Gluud, Christian; Jakobsen, Janus C.

    2018-01-01

    Background During recent years, systematic reviews of observational studies have compared digoxin to no digoxin in patients with atrial fibrillation or atrial flutter, and the results of these reviews suggested that digoxin seems to increase the risk of all-cause mortality regardless of concomitant heart failure. Our objective was to assess the benefits and harms of digoxin for atrial fibrillation and atrial flutter based on randomized clinical trials. Methods We searched CENTRAL, MEDLINE, Embase, LILACS, SCI-Expanded, BIOSIS for eligible trials comparing digoxin versus placebo, no intervention, or other medical interventions in patients with atrial fibrillation or atrial flutter in October 2016. Our primary outcomes were all-cause mortality, serious adverse events, and quality of life. Our secondary outcomes were heart failure, stroke, heart rate control, and conversion to sinus rhythm. We performed both random-effects and fixed-effect meta-analyses and chose the more conservative result as our primary result. We used Trial Sequential Analysis (TSA) to control for random errors. We used GRADE to assess the quality of the body of evidence. Results 28 trials (n = 2223 participants) were included. All were at high risk of bias and reported only short-term follow-up. When digoxin was compared with all control interventions in one analysis, we found no evidence of a difference on all-cause mortality (risk ratio (RR), 0.82; TSA-adjusted confidence interval (CI), 0.02 to 31.2; I2 = 0%); serious adverse events (RR, 1.65; TSA-adjusted CI, 0.24 to 11.5; I2 = 0%); quality of life; heart failure (RR, 1.05; TSA-adjusted CI, 0.00 to 1141.8; I2 = 51%); and stroke (RR, 2.27; TSA-adjusted CI, 0.00 to 7887.3; I2 = 17%). Our analyses on acute heart rate control (within 6 hours of treatment onset) showed firm evidence of digoxin being superior compared with placebo (mean difference (MD), -12.0 beats per minute (bpm); TSA-adjusted CI, -17.2 to -6.76; I2 = 0%) and inferior compared with beta blockers (MD, 20.7 bpm; TSA-adjusted CI, 14.2 to 27.2; I2 = 0%). Meta-analyses on acute heart rate control showed that digoxin was inferior compared with both calcium antagonists (MD, 21.0 bpm; TSA-adjusted CI, -30.3 to 72.3) and with amiodarone (MD, 14.7 bpm; TSA-adjusted CI, -0.58 to 30.0; I2 = 42%), but in both comparisons TSAs showed that we lacked information. Meta-analysis on acute conversion to sinus rhythm showed that digoxin compared with amiodarone reduced the probability of converting atrial fibrillation to sinus rhythm, but TSA showed that we lacked information (RR, 0.54; TSA-adjusted CI, 0.13 to 2.21; I2 = 0%). Conclusions The clinical effects of digoxin on all-cause mortality, serious adverse events, quality of life, heart failure, and stroke are unclear based on current evidence. Digoxin seems to be superior compared with placebo in reducing the heart rate, but inferior compared with beta blockers. The long-term effect of digoxin is unclear, as no trials reported long-term follow-up. More trials at low risk of bias and low risk of random errors assessing the clinical effects of digoxin are needed. Systematic review registration PROSPERO CRD42016052935 PMID:29518134

  19. Surgical treatment for ectopic atrial tachycardia.

    PubMed

    Graffigna, A; Vigano, M; Pagani, F; Salerno, G

    1992-08-01

    Atrial tachycardia is an infrequent but potentially dangerous arrhythmia which often determines cardiac enlargement. Surgical ablation of the arrhythmia is effective and safe, provided a careful atrial mapping is performed and the surgical technique is tailored to the individual focus location. Eight patients underwent surgical ablation of ectopic atrial tachycardia between 1977 and 1990. Different techniques were adopted for each patient according to the anatomical location of the focus and possibly associated arrhythmias. Whenever possible, a closed heart procedure was chosen. In 1 patient a double focal origin was found and treated by separate procedures. In 1 patient with ostium secundum atrial septal defect and atrial flutter, surgical isolation of the right appendage and the ectopic focus was performed. In all patients ectopic atrial tachycardia was ablated with maintenance of the sinoatrial and atrioventricular nodal function as well as internodal conduction. In follow-up up to December 1991, no recurrency was recorded.

  20. Atrial fibrillation associated with subclinical hyperthyroidism.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2009-05-29

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. It has also been reported that increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. We present a case of atrial fibrillation associated with subclinical hyperthyroidism, in a 78-year-old Italian woman. Also this case focuses attention on the importance of a correct evaluation of subclinical hyperthyroidism.

  1. Dronedarone.

    PubMed

    Hoy, Sheridan M; Keam, Susan J

    2009-08-20

    Oral dronedarone is a non-iodinated benzofurane derivative structurally related to amiodarone. Although it is considered a class III antiarrhythmic agent like amiodarone, it demonstrates multi-class electrophysiological activity. Data from the ATHENA study demonstrated that patients receiving oral dronedarone 400 mg twice daily for 12-30 months had a significantly lower risk of experiencing first hospitalization due to a cardiovascular event or death from any cause than those receiving placebo. Dronedarone exhibited rate- and rhythm-controlling properties in patients with atrial fibrilation (AF) or atrial flutter, significantly reducing the risk of a first recurrence of AF versus placebo following 12 months' therapy in the ADONIS and EURIDIS studies. In the ERATO study, dronedarone was also significantly more effective than placebo in terms of ventricular rate control. Furthermore, the beneficial effects of oral dronedarone on ventricular rate control were maintained during exercise and sustained with continued therapy. Oral dronedarone was generally well tolerated in the treatment of adult patients with AF and/or atrial flutter in clinical studies. The incidence of diarrhoea, nausea, bradycardia, rash and QT-interval prolongation was significantly higher with oral dronedarone than placebo in the large ATHENA study; however, serious cardiac-related adverse events were observed in <1% of oral dronedarone recipients.

  2. Synchronized emergency department cardioversion of atrial dysrhythmias saves time, money and resources.

    PubMed

    Jacoby, Jeanne L; Cesta, Mark; Heller, Michael B; Salen, Philip; Reed, James

    2005-01-01

    The strategy of elective synchronized cardioversion (EDCV) of new onset atrial fibrillation/flutter (AF/flutter) compares favorably to that of Emergency Department (ED) rate control and inpatient admission. This 1-year study comprised consecutive ED synchronized cardioversions performed on patients with new onset (< 48 h) AF/flutter; all were hemodynamically stable. A control group was obtained by chart review of all patients meeting the inclusion criteria admitted in the same year who were managed with rate control in the ED and inpatient admission. Thirty ED cardioversions were performed on 24 patients. Twenty-nine of 30 (97%) of ED cardioversions were successful. The mean hospital length of stay (LOS) for the EDCV group, including those admitted, was 22.8 h (95% CI: 1.7-44.0) compared to the control group: 55.6 h (all admitted) (95% CI: 41.6-69.6). Median LOS for the entire EDCV group was 4 h, compared with 39.3 h for the controls (p < 0.001). There was also a significant difference in median hospital charge, including ED care: EDCV group: $1598 vs. controls $4271 (p < 0.001). All of the study patients were contacted by telephone a minimum of 4 weeks after cardioversion to assess for complications, recidivism, and satisfaction. There were no complications in the EDCV group, and all expressed satisfaction with the procedure. Elective synchronized cardioversion in the ED is an effective strategy for management of new-onset AF/flutter and is associated with significant decreases in charges and length of stay as well as a high degree of patient satisfaction.

  3. Risk of atrial fibrillation in diabetes mellitus: A nationwide cohort study.

    PubMed

    Pallisgaard, Jannik L; Schjerning, Anne-Marie; Lindhardt, Tommi B; Procida, Kristina; Hansen, Morten L; Torp-Pedersen, Christian; Gislason, Gunnar H

    2016-04-01

    Diabetes has been associated with atrial fibrillation but the current evidence is conflicting. In particular knowledge regarding young diabetes patients and the risk of developing atrial fibrillation is sparse. The aim of our study was to investigate the risk of atrial fibrillation in patients with diabetes compared to the background population in Denmark. Through Danish nationwide registries we included persons above 18 years of age and without prior atrial fibrillation and/or diabetes from 1996 to 2012. The study cohort was divided into a background population without diabetes and a diabetes group. The absolute risk of developing atrial fibrillation was calculated and Poisson regression models adjusted for sex, age and comorbidities were used to calculate incidence rate ratios of atrial fibrillation. The total study cohort included 5,081,087 persons, 4,827,713 (95%) in the background population and 253,374 (5%) in the diabetes group. Incidence rates of atrial fibrillation per 1000 person years were stratified in four age groups from 18 to 39, 40 to 64, 65 to 74 and 75 to 100 years giving incidence rates (95% confidence intervals) of 0.02 (0.02-0.02), 0.99 (0.98-1.01), 8.89 (8.81-8.98) and 20.0 (19.9-20.2) in the background population and 0.13 (0.09-0.20), 2.10 (2.00-2.20), 8.41 (8.10-8.74) and 20.1 (19.4-20.8) in the diabetes group, respectively. The adjusted incidence rate ratios in the diabetes group with the background population as reference were 2.34 (1.52-3.60), 1.52 (1.47-1.56), 1.20 (1.18-1.23) and 0.99 (0.97-1.01) in the four age groups, respectively. Diabetes is an independent risk factor for developing atrial fibrillation/flutter, most pronounced in young diabetes patients. Routine screening for atrial fibrillation/flutter in diabetes patients might be beneficial and have therapeutic implications, especially in younger diabetes patients. Diabetes increases the risk of developing atrial fibrillation and especially young diabetes patients have a high relative risk. Increased focus on detecting atrial fibrillation in young diabetes patients might prove beneficial, and both anticoagulation treatment and anti-arrhythmic treatment strategies should be considered as soon as possible. © The European Society of Cardiology 2015.

  4. Atrial fibrillation or flutter

    MedlinePlus

    ... view Posterior heart arteries Anterior heart arteries Conduction system of the heart References January CT, Wann LS, Alpert ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows rigorous standards of quality and accountability. A.D.A.M. is ...

  5. Common Atrial Fibrillation Risk Alleles at 4q25 Predict Recurrence after Catheter-based Atrial Fibrillation Ablation

    PubMed Central

    Shoemaker, M. Benjamin; Muhammad, Raafia; Parvez, Babar; White, Brenda W.; Streur, Megan; Song, Yanna; Stubblefield, Tanya; Kucera, Gayle; Blair, Marcia; Rytlewski, Jason; Parvathaneni, Sunthosh; Nagarakanti, Rangadham; Saavedra, Pablo; Ellis, Christopher; Whalen, S. Patrick; Roden, Dan M; Darbar, Dawood

    2012-01-01

    Background Common single nucleotide polymorphisms (SNPs) at chromosome 4q25 (rs2200733, rs10033464) are associated with both lone and typical AF. Risk alleles at 4q25 have recently been shown to predict recurrence of AF after ablation in a population of predominately lone AF, but lone AF represents only 5–30% of AF cases. Objective To test the hypothesis that 4q25 AF risk alleles can predict response to AF ablation in the majority of AF cases. Methods Patients enrolled in the Vanderbilt AF Registry underwent 378 catheter-based AF ablations (median age 60 years, 71% male, 89% typical AF) between 2004 and 2011. The primary endpoint was time to recurrence of any non-sinus atrial tachyarrhythmia (atrial tachycardia, atrial flutter, or AF; [AT/AF]). Results Two-hundred AT/AF recurrences (53%) were observed. In multivariable analysis, the rs2200733 risk allele predicted a 24% shorter recurrence-free time (survival time ratio 0.76 95% confidence interval [CI] 0.6–0.95, P=0.016) compared with wild-type. The heterozygous haplotype demonstrated a 21% shorter recurrence-free time (survival time ratio = 0.79, 95% CI 0.62–0.99) and the homozygous risk allele carriers a 39% shorter recurrence-free time (survival time ratio = 0.61, 95% CI 0.37–1.0) (P=0.037). Conclusion Risk alleles at the 4q25 loci predict impaired clinical response to AF ablation in a population of predominately typical AF patients. Our findings suggest the rs2200733 polymorphism may hold promise as an as an objectively measured patient characteristic that can used as a clinical tool for selection of patients for AF ablation. PMID:23178686

  6. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    PubMed

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length <300 ms). Intermittent sensing of far-field R waves during sinus tachycardia caused 27 inappropriate AT/AF detections; these detections lasted 2.6+/-2.0 minutes. AT/AF was detected continuously in 27 of 28 patients who had spontaneous episodes of AT/AF (96%). The device memory recorded 90 appropriate AT/AF episodes lasting >1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  7. Cardiorespiratory interactions in patients with atrial flutter.

    PubMed

    Masè, Michela; Disertori, Marcello; Ravelli, Flavia

    2009-01-01

    Respiratory sinus arrhythmia (RSA) is generally known as the autonomically mediated modulation of the sinus node pacemaker frequency in synchrony with respiration. Cardiorespiratory interactions have been largely investigated during sinus rhythm, whereas little is known about interactions during reentrant arrhythmias. In this study, cardiorespiratory interactions at the atrial and ventricular level were investigated during atrial flutter (AFL), a supraventricular arrhythmia based on a reentry, by using cross-spectral analysis and computer modeling. The coherence and phase between respiration and atrial (gamma(AA)(2), phi(AA)) and ventricular (gamma(RR)(2), phi(RR)) interval series were estimated in 20 patients with typical AFL (68.0 +/- 8.8 yr) and some degree of atrioventricular (AV) conduction block. In all patients, atrial intervals displayed oscillations strongly coupled and in phase with respiration (gamma(AA)(2)= 0.97 +/- 0.05, phi(AA) = 0.71 +/- 0.31 rad), corresponding to a paradoxical lengthening of intervals during inspiration. The modulation pattern was frequency independent, with in-phase oscillations and short time delays (0.40 +/- 0.15 s) for respiratory frequencies in the range 0.1-0.4 Hz. Ventricular patterns were affected by AV conduction type. In patients with fixed AV conduction, ventricular intervals displayed oscillations strongly coupled (gamma(RR)(2)= 0.97 +/- 0.03) and in phase with respiration (phi(RR) = 1.08 +/- 0.80 rad). Differently, in patients with variable AV conduction, respiratory oscillations were secondary to Wencheback rhythmicity, resulting in a decreased level of coupling (gamma(RR)(2)= 0.50 +/- 0.21). Simulations with a simplified model of AV conduction showed ventricular patterns to originate from the combination of a respiratory modulated atrial input with the functional properties of the AV node. The paradoxical frequency-independent modulation pattern of atrial interval, the short time delays, and the complexity of ventricular rhythm characterize respiratory arrhythmia during AFL and distinguish it from normal RSA. These peculiar features can be explained by assuming a direct mechanical action of respiration on AFL reentrant circuit.

  8. Atrial Tachycardias Following Atrial Fibrillation Ablation

    PubMed Central

    Sághy, László; Tutuianu, Cristina; Szilágyi, Judith

    2015-01-01

    One of the most important proarrhythmic complications after left atrial (LA) ablation is regular atrial tachycardia (AT) or flutter. Those tachycardias that occur after atrial fibrillation (AF) ablation can cause even more severe symptoms than those from the original arrhythmia prior to the index ablation procedure since they are often incessant and associated with rapid ventricular response. Depending on the method and extent of LA ablation and on the electrophysiological properties of underlying LA substrate, the reported incidence of late ATs is variable. To establish the exact mechanism of these tachycardias can be difficult and controversial but correlates with the ablation technique and in the vast majority of cases the mechanism is reentry related to gaps in prior ablation lines. When tachycardias occur, conservative therapy usually is not effective, radiofrequency ablation procedure is mostly successful, but can be challenging, and requires a complex approach. PMID:25308808

  9. Atrial fibrillation patients with isolated pulmonary veins: Is sinus rhythm achievable?

    PubMed

    Szilágyi, Judit; Marcus, Gregory M; Badhwar, Nitish; Lee, Byron K; Lee, Randall J; Vedantham, Vasanth; Tseng, Zian H; Walters, Tomos; Scheinman, Melvin; Olgin, Jeffrey; Gerstenfeld, Edward P

    2017-07-01

    The cornerstone of atrial fibrillation (AF) ablation is isolation of the pulmonary veins (PVs). Patients with recurrent AF undergoing repeat ablation usually have PV reconnection (PVr). The ablation strategy and outcome of patients undergoing repeat ablation who have persistent isolation of all PVs (PVi) at the time of repeat ablation is unknown. We studied consecutive patients with recurrent AF undergoing repeat ablation and compared patients with PVi to those with PVr. One hundred fifty-two patients underwent repeat ablation, and of these, 25 patients (16.4%) had PVi. Patients with PVi underwent ablation targeting any isoproterenol induced AF triggers, atrial substrate, or inducible atrial tachycardias or flutters. Patients with PVi compared to PVr were more likely to have a history of persistent AF (64% vs. 26%; P < 0.0001), obesity (BMI 30.4 vs. 28.2; P = 0.05), and prior use of contact force sensing catheters (28% vs. 0.8%, P < 0.0001). After a mean follow-up of 19 ± 15 months, 56% of PVi patients remained in sinus rhythm compared to 76.3% of PVr patients (P = 0.036). In a multivariable model, PVi patients and those with cardiomyopathy had a higher risk of recurrent atrial tachyarrhythmias (HR = 3.6 95%, CI 1.6-8.3, P = 0.002 and HR = 6.2, 95% CI 2.3-16.3, P < 0.0001, respectively). In patients who have all PVs isolated at the time of the redo AF ablation, a strategy of targeting non-PV AF triggers and inducible flutters can still lead to AF freedom in more than half of patients. Patients with PVr, however, have a better long-term outcome. © 2017 Wiley Periodicals, Inc.

  10. HATCH score in the prediction of new-onset atrial fibrillation after catheter ablation of typical atrial flutter.

    PubMed

    Chen, Ke; Bai, Rong; Deng, Wenning; Gao, Chuanyu; Zhang, Jing; Wang, Xianqing; Wang, Shunbao; Fu, Haixia; Zhao, Yonghui; Zhang, Jiaying; Dong, Jianzeng; Ma, Changsheng

    2015-07-01

    New-onset atrial fibrillation (AF) is not uncommon after ablation of typical atrial flutter (AFL); however, limited data are available for a risk prediction model for the future occurrence of AF in patients with typical AFL undergoing successful catheter ablation. This study aimed to determine whether the HATCH score (which is based on hypertension, age ≥75 years, transient ischemic attack or stroke, chronic obstructive pulmonary disease, and heart failure) is useful for risk prediction of subsequent AF after ablation of typical AFL. A total of 216 consecutive patients presenting with typical AFL and no history of AF who underwent successful catheter ablation were enrolled in the study. The clinical endpoint was occurrence of new-onset AF during follow-up after ablation. During a follow-up period of 29.1 ± 18.3 months, 85 patients (39%) experienced at least 1 episode of AF. Multivariate Cox regression analysis demonstrated that the HATCH score (hazard ratio 1.784; 95% confidence interval 1.352-2.324; P < .001) and left atrial diameter (hazard ratio 1.270; 95% confidence interval 1.115-1.426; P < .001) were independently associated with new-onset AF after typical AFL ablation. The area under the receiver operator characteristic curve based on the HATCH score for prediction of new-onset AF was 0.743. The HATCH score could be used to stratify the patients into 2 groups with different incidences of new-onset AF (69% vs 27%, P < .001) at a cutoff value of 2. The HATCH score is a useful predictor of new-onset AF after typical AFL ablation. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Canadian Cardiovascular Society atrial fibrillation guidelines 2010: prevention and treatment of atrial fibrillation following cardiac surgery.

    PubMed

    Mitchell, L Brent

    2011-01-01

    Postoperative atrial fibrillation and atrial flutter (POAF) are the most common complications of cardiac surgery that require intervention or prolong intensive care unit and total hospital stay. For some patients, these tachyarrhythmias have important consequences including patient discomfort/anxiety, hemodynamic deterioration, cognitive impairment, thromboembolic events including stroke, exposure to the risks of antiarrhythmic treatments, longer hospital stay, and increased health care costs. We conclude that prevention of POAF is a worthwhile exercise and recommend that the dominant therapy for this purpose be β-blocker therapy, especially the continuation of β-blocker therapy that is already in place. When β-blocker therapy is contraindicated, amiodarone prophylaxis is recommended. If both of these therapies are contraindicated, therapy with either intravenous magnesium or biatrial pacing is suggested. Patients at high risk of POAF may be considered for first-line amiodarone therapy, first-line sotalol therapy, or combination prophylactic therapy. The treatment of POAF may follow either a rate-control approach (with the dominant therapy being β-blocking drugs) or a rhythm-control approach. Anticoagulation should be considered if persistent POAF lasts >72 hours and at the point of hospital discharge. The ongoing need for any POAF treatment (including anticoagulation) should be reconsidered 6-12 weeks after the surgical procedure. Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  12. Is HATCH score a reliable predictor of atrial fibrillation after cavotricuspid isthmus ablation for typical atrial flutter?

    PubMed

    García-Seara, Javier; Gude Sampedro, Francisco; Martínez Sande, Jose L; Fernández López, Xesus Alberte; Rodríguez Mañero, Moisés; González Melchor, Laila; Alvarez Alvarez, Belén; Iglesias Alvarez, Diego; González Juanatey, José Ramón

    2016-09-01

    We determined the effectiveness of the HATCH score in patients with typical atrial flutter (AFl) undergoing cavotricuspid isthmus (CTI) ablation to predict long-term atrial fibrillation (AF). We conducted an observational retrospective single-center cohort study including all patients admitted to our hospital for a CTI ablation between 1998 and 2010. The patients were divided into four categories: 1) new-onset AF (no prior AF and AF during follow-up (FU)); 2) old AF (prior AF and no AF during FU); 3) prior and post AF (AF prior and post CTI ablation); and 4) no AF. Four hundred and eight patients were included. In patients without prior AF, the hazard ratio (HR) for new-onset AF during FU was 0.98 (CI 95%: 0.65-1.50; p = 0.95) and 1.00 (CI 95%: 0.57-1.77; p = 0.98) for HATCH ≥ 2 and HATCH ≥ 3, respectively. In patients with prior AF, the HR for AF was 1.41 (CI 95%: 0.87-2.28; p = 0.17) and 1.79 (CI 95%: 0.96-3.35; p = 0.06), for HATCH ≥ 2 and HATCH ≥ 3, respectively. Left atrial enlargement was positively correlated with the occurrence of AF during FU, especially in the subgroup without prior AF, which had a HR of 2.44 (CI 95%: 1.35-4.40; p = 0.003), a HR of 2.88 (CI 95%: 1.36-6.10; p = 0.006) and a HR of 3.68 (CI 95%: 1.71-7.94; p = 0.001), for slight, moderate and severely dilated left atrial dimension, respectively, compared with a normal value. HATCH score did not predict AF in patients with typical AFl who underwent CTI ablation. Basal left atrium dimension could help predict new-onset AF.

  13. [The vulnerability of the human atrium. I. Correlations between vulnerability, sinus node recovery time and intraatrial conduction time (author's transl)].

    PubMed

    Pop, T; Fleischmann, D; Effert, S

    1976-09-01

    Using the extrastimulus method in 100 patients, premature impulses were applied during the relative refractory period of the right atrium. Depending on the atrial response to these impulses we divided our patients in the following 3 groups: Group A: no repetitive firing (61 patients); group B: 1 to 5 additional atrial extrasystoles with a total duration of maximum 1.5 s (27 patients); group C: runs of atrial flutter or fibrilation for at least 8 s (12 patients). The statistical analysis of the following parameters: age, PA interval, absolute and corrected sinus node recovery time did not show any significant difference between the 3 groups. These results suggest that the investigated parameters are of no great importance in the genesis of the atrial vulnerability.

  14. Vernakalant: RSD 1235, RSD-1235, RSD1235.

    PubMed

    2007-01-01

    Vernakalant is an atrial-selective antiarrhythmic drug discovered by Cardiome Pharma (formerly Nortran Pharmaceuticals). Vernakalant may have potential in the treatment of atrial arrhythmias, including acute atrial fibrillation and atrial flutter. Vernakalant is a mixed sodium/potassium channel blocker and selectively blocks ion channels in the heart that are known to be active during episodes of atrial fibrillation. An IV formulation of vernakalant is awaiting registration in the US for the acute conversion of atrial fibrillation. Also, an oral formulation of the compound is in phase II clinical development as a chronic-use product for the maintenance of normal heart rhythm following termination of atrial fibrillation. Cardiome is seeking co-development partners for intravenous vernakalant in the treatment of atrial arrhythmia, atrial fibrillation and atrial flutter in Europe and Japan. In October 2003, Cardiome Pharma and Fujisawa Healthcare, the US subsidiary of Fujisawa Pharmaceutical Co., Ltd (now Astellas Pharma), executed a $US68 million strategic partnership agreement for the co-development of vernakalant. On 1 April 2005, Fujisawa merged with Yamanouchi to form Astellas Pharma. The partnership grants Astellas Pharma exclusive commercialisation rights for vernakalant. Under the terms of the agreement, Cardiome and Astellas Pharma will co-develop vernakalant as an intravenous formulation for the treatment of atrial fibrillation and atrial flutter for North American markets. Astellas Pharma will be financially responsible for 75% of all future clinical development costs, with Cardiome responsible for the remaining 25% of costs. Astellas Pharma will be responsible for the development plan, NDA application (and NDA re-submission costs) and registration, along with the commercial manufacturing, marketing and sale of vernakalant. Cardiome will manage the phase III trials ACT 1 and ACT 2 and will also be responsible for the continued manufacturing of clinical supplies of vernakalant. Cardiome will receive royalties on end-user sales of vernakalant reflective of Cardiome's 25% share of development costs and other financial considerations. Product rights to the IV formulation of vernakalant for markets outside of North America and world rights to the oral formulation of vernakalant for chronic atrial fibrillation are not included within the scope of this partnership. Cardiome intends to form future additional alliances for these product opportunities or maintain such opportunities for commercialisation on its own. Cardiome and Astellas amended their agreement for vernakalant in relation to the re-submission of the NDA with the US FDA. Under the terms of the new agreement, Astellas agreed to fund 100% of the costs associated with re-submission, including engagement and external consultants. Astellas also agreed to modify the timing of the $US10 million NDA milestone to the date of resubmission. In February 2005, Cardiome Pharma received a $US6 million milestone payment from its co-development partner, Fujisawa Healthcare Inc. This milestone payment was triggered by the successful completion of ACT 1.A pivotal phase II trial demonstrated in September 2002 that vernakalant rapidly and effectively terminated recent onset atrial fibrillation and the study met both primary and secondary study endpoints. Following discussions with the FDA, Cardiome initiated three separate phase III clinical trials in order to enable Cardiome to apply for marketing approval for vernakalant. In August 2003, Cardiome Pharma commenced patient dosing in its first phase III efficacy study of vernakalant for the acute treatment of atrial fibrillation. This initial study, called ACT 1 (Atrial fibrillation Conversion Trial 1), measured the safety and efficacy of vernakalant in 416 patients with atrial arrhythmias. The placebo-controlled study was carried out in 45 centers in the US, Canada and Scandinavia. The ACT 1 study included two substudies of 60 patients with atrial flutter and 119 patients with longer term atrial fibrillation. The primary efficacy endpoint was acute conversion of atrial arrhythmia to normal heart rhythm. Cardiome commenced its second phase III efficacy study in March 2004, known as ACT 2. The ACT 2 study in post-cardiac surgery (coronary artery bypass graft) patients with atrial fibrillation, evaluated the safety and efficacy of vernakalant (IV) in the termination of atrial arrhythmias in patients after cardiac surgery. Around 210 patients from 25 centres in the US, Canada and Europe were enrolled in this study. The primary efficacy endpoint was acute conversion of atrial arrhythmias to normal heart rhythm. The ACT 2 study is ongoing. The third phase III study, known as ACT 3 (Atrial arrhythmia Conversion Trial 3), was initiated by Cardiome Pharma in July 2004. In September 2005, Cardiome and Astellas reported that ACT 3 had been completed, achieving its primary endpoint, with over half of the 170 patients with recent-onset atrial fibrillation (AF) who received vernakalant intravenously converting to normal heart rhythm, compared with only 4% in the placebo group. The study was being conducted by co-development partner Astellas Pharma and measured the safety and efficacy of intravenous vernakalant in recent onset atrial arrhythmia patients. The placebo-controlled study was being carried out in 276 patients in more than 50 centres throughout the world.ACT 4, a phase III safety study evaluating safety of IV vernakalant in approximately 120 AF patients from 30 centres in the US, Canada and Europe, was initiated in October 2005. Results from this trial are expected to supplement trial results from the pivotal ACT 1 and 3 trials. This study is ongoing. Cardiome Pharma successfully completed phase I studies for its controlled-release oral formulation of vernakalant in 2005. The oral, controlled-release formulation of vernakalant is expected to help prevent or slow the recurrence of atrial fibrillation, and will be used as a follow-on therapy to intravenous vernakalant.

  15. Heart-specific overexpression of (pro)renin receptor induces atrial fibrillation in mice.

    PubMed

    Lian, Hong; Wang, Xiaojian; Wang, Juan; Liu, Ning; Zhang, Li; Lu, Yingdong; Yang, Yanmin; Zhang, Lianfeng

    2015-04-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia, causing substantial cardiovascular morbidity and mortality. The renin-angiotensin system (RAS) has been shown to be involved in the pathophysiology of AF. The (pro)renin receptor [(p)RR] is the last identified member of RAS. However, the role of (p)RR in AF is still unknown. Circulating levels of (p)RR were determined using an immunosorbent assay in 22 patients with AF (paroxysmal or persistent) and 22 healthy individuals. The plasma levels of (p)RR increased 3.6-fold in AF patients (P<0.001), indicating a relationship between (p)RR and AF. To investigate the role of (p)RR in the regulation of cardiac arrhythmia, we generated a transgenic mouse with overexpression of human (p)RR gene specifically in the heart. Electrocardiograms from (p)RR transgenic mice showed typical atrial flutter since 2 months, then spontaneously converted to atrial fibrillation by 10 months. The atria of the transgenic mice demonstrated significant dilation and fibrosis, and exhibited a high incidence of sudden death. Additionally, the genes of SERCA and HCN4, which are involved in the electrophysiology of AF, were significantly down-regulated and up-regulated respectively in transgenic mice atria. The phosphorylation of Erk1/2 significantly increased in the atria of the transgenic mice, and the activated Erk1/2 was found predominantly in cardiac fibroblasts, suggesting that the transgenic (p)RR gene may induce atrial fibrillation by activation of Erk1/2 in the cardiac fibroblasts of the atria. (p)RR promotes atrial structural and electrical remodeling in vivo, which indicates that (p)RR plays an important role in the pathological development of AF. Copyright © 2015. Published by Elsevier Ireland Ltd.

  16. Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter.

    PubMed

    Gould, Paul A; Booth, Cameron; Dauber, Kieran; Ng, Kevin; Claughton, Andrew; Kaye, Gerald C

    2016-12-01

    This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this. © 2016 Wiley Periodicals, Inc.

  17. Bayés syndrome and acute cardioembolic ischemic stroke.

    PubMed

    Arboix, Adrià; Martí, Lucía; Dorison, Sebastien; Sánchez, María José

    2017-03-16

    Bayés syndrome is an under-recognized clinical condition characterized by advanced interatrial block. Bayés syndrome is a subclinical disease that manifests electrocardiographically as a prolonged P wave duration > 120 ms with biphasic morphology ± in the inferior leads. The clinical relevance of Bayés syndrome lies in the fact that is a clear arrhythmological syndrome and has a strong association with supraventricular arrhythmias, particularly atypical atrial flutter and atrial fibrillation. Likewise, Bayés syndrome has been recently identified as a novel risk factor for non-lacunar cardioembolic ischemic stroke and vascular dementia. Advanced interatrial block can be a risk for embolic stroke due to its known sequelae of left atrial dilation, left atrial electromechanical dysfunction or atrial tachyarrhythmia (paroxysmal or persistent atrial fibrillation), conditions predisposing to thromboembolism. Bayés syndrome may be responsible for some of the unexplained ischemic strokes and shall be considered and investigated as a possible cause for cryptogenetic stroke. In summary, Bayés syndrome is a poorly recognized cardiac rhythm disorder with important cardiologic and neurologic implications.

  18. WITHDRAWN: Pharmacological cardioversion for atrial fibrillation and flutter.

    PubMed

    Cordina, John; Mead, Gillian E

    2017-11-15

    Atrial fibrillation is the commonest cardiac dysrhythmia. It is associated with significant morbidity and mortality. There are two approaches to the management of atrial fibrillation: controlling the ventricular rate or converting to sinus rhythm in the expectation that this would abolish its adverse effects. To assess the effects of pharmacological cardioversion of atrial fibrillation in adults on the annual risk of stroke, peripheral embolism, and mortality. We searched the Cochrane Controlled Trials Register (Issue 3, 2002), MEDLINE (2000 to 2002), EMBASE (1998 to 2002), CINAHL (1982 to 2002), Web of Science (1981 to 2002). We hand searched the following journals: Circulation (1997 to 2002), Heart (1997 to 2002), European Heart Journal (1997-2002), Journal of the American College of Cardiology (1997-2002) and selected abstracts published on the web site of the North American Society of Pacing and Electrophysiology (2001, 2002). Randomised controlled trials or controlled clinical trials of pharmacological cardioversion versus rate control in adults (>18 years) with acute, paroxysmal or sustained atrial fibrillation or atrial flutter, of any duration and of any aetiology. One reviewer applied the inclusion criteria and extracted the data. Trial quality was assessed and the data were entered into RevMan. We identified two completed studies AFFIRM (n=4060) and PIAF (n=252). We found no difference in mortality between rhythm control and rate control relative risk 1.14 (95% confidence interval 1.00 to 1.31).Both studies show significantly higher rates of hospitalisation and adverse events in the rhythm control group and no difference in quality of life between the two treatment groups.In AFFIRM there was a similar incidence of ischaemic stroke, bleeding and systemic embolism in the two groups. Certain malignant dysrhythmias were significantly more likely to occur in the rhythm control group. There were similar scores of cognitive assessment.In PIAF, cardioverted patients enjoyed an improved exercise tolerance but there was no overall benefit in terms of symptom control or quality of life. There is no evidence that pharmacological cardioversion of atrial fibrillation to sinus rhythm is superior to rate control. Rhythm control is associated with more adverse effects and increased hospitalisation. It does not reduce the risk of stroke. The conclusions cannot be generalised to all people with atrial fibrillation. Most of the patients included in these studies were relatively older (>60 years) with significant cardiovascular risk factors.

  19. Pharmacological cardioversion for atrial fibrillation and flutter.

    PubMed

    Cordina, J; Mead, G

    2005-04-18

    Atrial fibrillation is the commonest cardiac dysrhythmia. It is associated with significant morbidity and mortality. There are two approaches to the management of atrial fibrillation: controlling the ventricular rate or converting to sinus rhythm in the expectation that this would abolish its adverse effects. To assess the effects of pharmacological cardioversion of atrial fibrillation in adults on the annual risk of stroke, peripheral embolism, and mortality. We searched the Cochrane Controlled Trials Register (Issue 3, 2002), MEDLINE (2000 to 2002), EMBASE (1998 to 2002), CINAHL (1982 to 2002), Web of Science (1981 to 2002). We hand searched the following journals: Circulation (1997 to 2002), Heart (1997 to 2002), European Heart Journal (1997-2002), Journal of the American College of Cardiology (1997-2002) and selected abstracts published on the web site of the North American Society of Pacing and Electrophysiology (2001, 2002). Randomised controlled trials or controlled clinical trials of pharmacological cardioversion versus rate control in adults (>18 years) with acute, paroxysmal or sustained atrial fibrillation or atrial flutter, of any duration and of any aetiology. One reviewer applied the inclusion criteria and extracted the data. Trial quality was assessed and the data were entered into RevMan. We identified two completed studies AFFIRM (n=4060) and PIAF (n=252). We found no difference in mortality between rhythm control and rate control relative risk 1.14 (95% confidence interval 1.00 to 1.31). Both studies show significantly higher rates of hospitalisation and adverse events in the rhythm control group and no difference in quality of life between the two treatment groups. In AFFIRM there was a similar incidence of ischaemic stroke, bleeding and systemic embolism in the two groups. Certain malignant dysrhythmias were significantly more likely to occur in the rhythm control group. There were similar scores of cognitive assessment. In PIAF, cardioverted patients enjoyed an improved exercise tolerance but there was no overall benefit in terms of symptom control or quality of life. There is no evidence that pharmacological cardioversion of atrial fibrillation to sinus rhythm is superior to rate control. Rhythm control is associated with more adverse effects and increased hospitalisation. It does not reduce the risk of stroke. The conclusions cannot be generalised to all people with atrial fibrillation. Most of the patients included in these studies were relatively older (>60 years) with significant cardiovascular risk factors.

  20. Atrial flutter with spontaneous 1:1 atrioventricular conduction in adults: an uncommon but frequently missed cause for syncope/presyncope.

    PubMed

    Turitto, Gioia; Akhrass, Philippe; Leonardi, Marino; Saponieri, Cesare; Sette, Antonella; El-Sherif, Nabil

    2009-01-01

    To compare patients with atrial flutter (AFl) and 1:1 atrioventricular conduction (AVC) with patients with AFl and higher AVC. The characteristics of 19 patients with AFl and 1:1 AVC (group A) were compared with those of 116 consecutive patients with AFl and 2:1 AVC or higher degree AV block (group B). Age, gender, and left ventricular function were similar in the two groups. In group A versus group B, more patients had no structural heart disease (42% vs 17%, P < 0.05) and syncope/presyncope (90% vs 12%, P < 0.05). The AFl cycle length (CL) in group A was longer than in group B (265 +/- 24 ms vs 241 +/- 26 ms, P < 0.01). The transition from AFl with 1:1 to 2:1 AVC or vice versa was associated with small but definite changes in AFl CL, which showed larger variations in response to sympathetic stimulation. In group A patients who were studied off drugs, the atrial-His interval was not different from group B, but maximal atrial pacing rate with 1:1 AVC was faster. In group A, five patients were misdiagnosed as ventricular tachyarrhythmias, and three with a defibrillator received inappropriate shocks. Four patients had ablation of AVC and six had ablation of AFl circuit. The main difference between groups A and B may be an inherent capacity of the AV node for faster conduction, especially in response to increased sympathetic tone. The latter affects not only AVC but also the AFl CL. One should be aware of the different presentations of AFl with 1:1 AVC to avoid misdiagnosis/mismanagement and to consider the diagnosis in patients with narrow or wide QRS tachycardia and rates above 220/min.

  1. Association between transthoracic impedance and electrical cardioversion success with biphasic defibrillators: An analysis of 1055 shocks for atrial fibrillation and flutter.

    PubMed

    Sadek, Mouhannad M; Chaugai, Varsha; Cleland, Mark J; Zakutney, Timothy J; Birnie, David H; Ramirez, F Daniel

    2018-03-13

    The relevance of transthoracic impedance (TTI) to electrical cardioversion (ECV) success for atrial tachyarrhythmias when using biphasic waveform defibrillators is unknown. TTI is predictive of ECV success with contemporary defibrillators. De-identified data stored in biphasic defibrillator memory cards from ECV attempts for atrial fibrillation (AF) or atrial flutter (AFL) over a 2-year period at our center were evaluated. ECV success, defined as arrhythmia termination and ≥ 1 sinus beat, was adjudicated by 2 blinded cardiac electrophysiologists. The association between TTI and ECV success was assessed via Cochrane-Armitage trend and Spearman rank correlation tests, as well as simple and multivariable logistic regression. The influence of TTI on the number of shocks and on cumulative energy delivered per patient was also examined. 703 patients (593 with AF, 110 with AFL) receiving 1055 shocks were included. Last shock success was achieved in 88.0% and 98.2% of patients with AF and AFL, respectively. In patients with AF, TTI was positively associated with last shock failure (P trend  =0.019), the need for multiple shocks (P trend  <0.001), and cumulative energy delivered (ρ = 0.348; P < 0.001). After adjusting for first shock energy, 10-Ω increments in TTI were associated with odds ratios of 1.36 (95% CI: 1.24-1.49) and 1.22 (95% CI: 1.09-1.37) for first and last shock failure, respectively (P < 0.001 for both). Although contemporary defibrillators are designed to compensate for TTI, this variable continues to be associated with ECV failure in patients with AF. Strategies to lower TTI during ECV for AF may improve procedural success. © 2018 Wiley Periodicals, Inc.

  2. Right atrial angiographic evaluation of the posterior isthmus: relevance for ablation of typical atrial flutter.

    PubMed

    Heidbüchel, H; Willems, R; van Rensburg, H; Adams, J; Ector, H; Van de Werf, F

    2000-05-09

    Gaining anatomic information about the posterior isthmus is not generally part of flutter ablation procedures. We postulated that right atrial (RA) angiography could rationalize the ablation approach by revealing the conformation of the isthmus. In 100 consecutive patients, biplane RA angiography was performed before ablation to guide catheter contact with the isthmus along its length. Angiography showed a wide variation in the width of the isthmus (17 to 54 mm; 31.3+/-7.9), its angle with the inferior vena cava in the right anterior oblique projection (68 degrees to 114 degrees; 90.3+/-9.0 degrees ), and its lateral position relative to the inferior vena cava in the left anterior oblique projection. A deep sub-Eustachian recess was revealed in 47%, with a mean depth of 4.3+/-2.1 mm (1.5 to 9.4). A Eustachian valve was visualized in 24%. Ablation resulted in bidirectional conduction block (which could be transient) in all, with a median of 2 dragging radiofrequency (RF) applications (2.3+/-2.5 RF applications; 57 degrees C, < or =99 seconds each). Permanent block was achieved in 99%, with a median of 3 RF applications (3.4+/-3.0). The presence of a Eustachian valve or concave isthmus was associated with statistically more RF applications; the same trend was seen for patients with deep pouches. The number of RF applications decreased statistically throughout the study, indicating a learning curve. No patient had a recurrence after a follow-up of 13+/-11 months. Right atrial angiography reveals a highly variable isthmus anatomy, often showing particular configurations that can make ablation more laborious. Rational adaptation of the ablation approach to these anatomic findings may contribute to successful ablation.

  3. Rationale and design of a prospective study of the clinical significance of atrial arrhythmias detected by implanted device diagnostics: the TRENDS study.

    PubMed

    Glotzer, Taya V; Daoud, Emile G; Wyse, D George; Singer, Daniel E; Holbrook, Reece; Pruett, Khadeeja; Smith, Kenneth; Hilker, Christopher E

    2006-01-01

    Sustained atrial fibrillation (AF) is a common risk factor for stroke. While intermittent AF also appears to pose a substantial stroke risk, the quantitative relationship between the percentage of time spent in AF and stroke risk is poorly specified and "intermittent" AF is not the same as paroxysmal AF. Improved assessment of the impact of AF burden on stroke risk will allow more targeted and safer use of antithrombotic therapy. The primary objective of this study is to determine if AT/AF (all device detected atrial tachyarrhythmias, including atrial flutter, atrial fibrillation, and atrial tachycardia) burden over a 30 day period is an independent predictor of the occurrence of ischemic stroke, transient ischemic attack (TIA) and/or systemic embolism in subjects not receiving anticoagulation therapy. TRENDS is a prospective, post-market, non-randomized, multicenter study designed to enroll 3100 subjects who have an independent Class I/II indication for cardiac rhythm device implantation and who have demographic features suggestive of an increased risk for thromboembolic complications related to AT/AF. All implanted devices will have the ability to collect long-term AT/AF burden trending data and will be equivalently programmed to ensure consistent data collection. All subjects will be followed with device interrogations every 3 months and clinic visits every 6 months for 1 year. Subjects with a documented history of AT/AF prior to enrollment and those who develop AT/AF during the 12-month follow-up will be followed until the last subject enrolled in the study has completed their 24-month follow-up. The results of the TRENDS study should help clarify the implications of data retrieved from an implantable device with regard to the risk for thromboembolic complications from atrial arrhythmias, even in the absence of symptoms.

  4. [The risk of direct current countershock].

    PubMed

    Gajek, J; Zyśko, D

    2001-07-01

    Direct current cardioversion (DCC) is a procedure commonly used to restore the sinus rhythm in patients with supraventricular and ventricular arrhythmias. Its safety, regarding the use of electric current, is still a matter of controversy and debate. The patients with atrial fibrillation/flutter, supraventricular or ventricular tachycardia represent a broad spectrum of clinical conditions and it is difficult to draw the conclusions. The high success rate of DCC in restoring the sinus rhythm, may be partly responsible for enhancing and revealing proarrhythmic properties of antiarrhythmic drugs. The deaths described as a complications of DCC were mainly due to the proarrhythmia and less common to the progression of the pathologic process. The embolic, arrhythmic and anesthetic complications of DCC can be prevented if the known recommendations of performing the DCC are followed. The authors review critically the literature data about the complications of the procedure and come to the conclusion of safety of DCC.

  5. Incidence, type of atrial fibrillation and risk factors for stroke: a population-based cohort study

    PubMed Central

    Johansson, Cecilia; Dahlqvist, Erik; Andersson, Jonas; Jansson, Jan-Håkan; Johansson, Lars

    2017-01-01

    Purpose The aims of this study were to estimate the incidence of atrial fibrillation and atrial flutter (AF), to assess the presence of provoking factors and risk factors for stroke and systemic embolism, and to determine the type of AF in patients with first-diagnosed AF. Patients and methods This cohort study was performed in northern Sweden between January 1, 2011 and December 31, 2012. Diagnosis registries were searched for the International Classification of Diseases-10 code for AF (I48) to identify cases of incident AF. All AF diagnoses were electrocardiogram-verified. Data pertaining to provoking factors, type of AF and presence of risk factors for stroke and systemic embolism according to the CHA2DS2-VASc score were obtained from medical records. Results The incidence of AF in the entire population was 4.0 per 1,000 person-years. The incidence was 27.5 per 1,000 person-years in patients aged ≥80 years. A total of 21% of all patients had a provoking factor in association with the first-diagnosed episode of AF. The CHA2DS2-VASc score was 2 or higher in 81% of the patients. Permanent AF was the most common type of AF (29%). Conclusion There was a considerable increase in the incidence of AF with age, and a provoking factor was found in one-fifth. The most common type of AF was permanent AF. Four in five patients had a CHA2DS2-VASc score of 2 or more. PMID:28182159

  6. Post-parathyroidectomy thyrotoxicosis and atrial flutter: a case for caution

    PubMed Central

    Asmar, Abdo

    2011-01-01

    Despite transient hyperthyroidism reportedly occurring in ∼30% of post-parathyroidectomy (PTX) patients with primary hyperparathyroidism, it has rarely been described in the internal medicine literature. It occurs within days of surgery, is usually clinically mild or silent, and typically spontaneously resolves within weeks. Patients can, however, unusually present with symptoms and signs of thyrotoxicosis, including arrhythmias. We report a case of a hemodialysis patient who developed self-limited hyperthyroidism after intra-operative thyroid manipulation and excision during PTX surgery for secondary hyperparathyroidism that failed medical management. The patient was symptomatic with agitation, restlessness and new-onset atrial flutter, which required electrical cardioversion and temporary beta blockade. It is important that clinicians be aware of this potential surgical complication, so as to not attribute manifestations to post-PTX divalent cation disorders (i.e. hungry bone syndrome), thereby allowing prompt diagnosis and treatment. Post-operative monitoring of thyroid function is warranted for at least some subsets of patients: individuals who undergo thyroid exploration and palpation as part of their surgery to localize the parathyroid glands, as well as those with underlying cardiac disease or who are otherwise at high risk from even mild states of hyperthyroidism. PMID:25984129

  7. Radiofrequency Ablation of Left Atrial Reentrant Tachycardias in Rheumatic Mitral Valve Disease: A Case Series.

    PubMed

    Prabhu, Mukund A; Thajudeen, Anees; Vk, Ajit Kumar; J, Tharakan; B V, Prasad Srinivas; Namboodiri, Narayanan

    2017-01-01

    Left atrial (LA) reentrant tachycardias are not uncommon in regions where rheumatic heart disease is prevalent. Some of these arrhythmias may be curable by radiofrequency ablation (RFA). However, there are limited data pertaining to this in existing literature. Three patients who had rheumatic mitral valve disease with past history of surgical-/catheter-based intervention and having no significant residual disease had symptomatic atrial flutter despite optimal medical management. An electrophysiological study confirmed an LA focal/micro-reentrant mechanism in all. There was patchy scarring of the LA, and successful RFA of these arrhythmias could be achieved. The focal nature of the scar in these patients may suggest that the rheumatic involvement of the atrium or the hemodynamic consequence of the vulvar lesion causes nonuniform insult to the atrial tissue and limited scar. At least in some patients with limited scarring, early RFA may help in the maintenance of sinus rhythm. © 2016 Wiley Periodicals, Inc.

  8. Relation of Milrinone Following Surgery for Congenital Heart Disease to Significant Postoperative Tachyarrhythmias

    PubMed Central

    Smith, Andrew H.; Owen, Jill; Borgman, Kristie Y.; Fish, Frank A.; Kannankeril, Prince J.

    2011-01-01

    Milrinone reduces the risk of low cardiac output syndrome for some pediatric patients following congenital heart surgery. Data from adults undergoing cardiac surgery suggest an association between milrinone and increased risk for postoperative arrhythmias. We tested the hypothesis that milrinone is an independent risk factor for tachyarrhythmias following congenital heart surgery. Subjects undergoing congenital heart surgery at our institution were consecutively enrolled for 38 months, through September 2010. Data was prospectively collected, including review of full-disclosure telemetry and the medical record. Over 38 months, 603 enrolled subjects underwent 724 operative procedures. The median age was 5.5 months (0.0–426), weight was 6.0 kg (0.7–108), and the cohort was 45% female. Overall arrhythmia incidence was 50%, most commonly monomorphic ventricular tachycardia (n=85, 12%), junctional ectopic tachycardia (n=69, 10%), accelerated junctional rhythm (n=58, 8%), and atrial tachyarrhythmias (including atrial fibrillation, atrial flutter, and ectopic or chaotic atrial tachycardia, n=58, 8%). Multivariate logistic regression analysis demonstrated that independent of age less than 1 month, use of cardiopulmonary bypass, duration of cardiopulmonary bypass, RACHS-1 score greater than 3, and the use of epinephrine or dopamine, milrinone use on admission to the cardiac intensive care unit remained independently associated with an increase in the odds of postoperative tachyarrhythmia resulting in an intervention (OR 2.8 [95%CI 1.3–6.0], p=0.007). In conclusion, milrinone use is an independent risk factor for clinically significant tachyarrhythmias in the early postoperative period following congenital heart surgery. PMID:21890079

  9. Health Literacy and Awareness of Atrial Fibrillation.

    PubMed

    Reading, Stephanie R; Go, Alan S; Fang, Margaret C; Singer, Daniel E; Liu, In-Lu Amy; Black, Mary Helen; Udaltsova, Natalia; Reynolds, Kristi

    2017-04-11

    Atrial fibrillation (AF) is the most common clinically significant arrhythmia in adults and a major risk factor for ischemic stroke. Nonetheless, previous research suggests that many individuals diagnosed with AF lack awareness about their diagnosis and inadequate health literacy may be an important contributing factor to this finding. We examined the association between health literacy and awareness of an AF diagnosis in a large, ethnically diverse cohort of Kaiser Permanente Northern and Southern California adults diagnosed with AF between January 1, 2006 and June 30, 2009. Using self-reported questionnaire data completed between May 1, 2010 and September 30, 2010, awareness of an AF diagnosis was evaluated using the question "Have you ever been told by a doctor or other health professional that you have a heart rhythm problem called atrial fibrillation or atrial flutter?" and health literacy was assessed using a validated 3-item instrument examining problems because of reading, understanding, and filling out medical forms. Of the 12 517 patients diagnosed with AF, 14.5% were not aware of their AF diagnosis and 20.4% had inadequate health literacy. Patients with inadequate health literacy were less likely to be aware of their AF diagnosis compared with patients with adequate health literacy (prevalence ratio=0.96; 95% CI [0.94, 0.98]), adjusting for sociodemographics, health behaviors, and clinical characteristics. Lower health literacy is independently associated with less awareness of AF diagnosis. Strategies designed to increase patient awareness of AF and its complications are warranted among individuals with limited health literacy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Fish oil and postoperative atrial fibrillation: the Omega-3 Fatty Acids for Prevention of Post-operative Atrial Fibrillation (OPERA) randomized trial.

    PubMed

    Mozaffarian, Dariush; Marchioli, Roberto; Macchia, Alejandro; Silletta, Maria G; Ferrazzi, Paolo; Gardner, Timothy J; Latini, Roberto; Libby, Peter; Lombardi, Federico; O'Gara, Patrick T; Page, Richard L; Tavazzi, Luigi; Tognoni, Gianni

    2012-11-21

    Postoperative atrial fibrillation or flutter (AF) is one of the most common complications of cardiac surgery and significantly increases morbidity and health care utilization. A few small trials have evaluated whether long-chain n-3-polyunsaturated fatty acids (PUFAs) reduce postoperative AF, with mixed results. To determine whether perioperative n-3-PUFA supplementation reduces postoperative AF. The Omega-3 Fatty Acids for Prevention of Post-operative Atrial Fibrillation (OPERA) double-blind, placebo-controlled, randomized clinical trial. A total of 1516 patients scheduled for cardiac surgery in 28 centers in the United States, Italy, and Argentina were enrolled between August 2010 and June 2012. Inclusion criteria were broad; the main exclusions were regular use of fish oil or absence of sinus rhythm at enrollment. Patients were randomized to receive fish oil (1-g capsules containing ≥840 mg n-3-PUFAs as ethyl esters) or placebo, with preoperative loading of 10 g over 3 to 5 days (or 8 g over 2 days) followed postoperatively by 2 g/d until hospital discharge or postoperative day 10, whichever came first. Occurrence of postoperative AF lasting longer than 30 seconds. Secondary end points were postoperative AF lasting longer than 1 hour, resulting in symptoms, or treated with cardioversion; postoperative AF excluding atrial flutter; time to first postoperative AF; number of AF episodes per patient; hospital utilization; and major adverse cardiovascular events, 30-day mortality, bleeding, and other adverse events. At enrollment, mean age was 64 (SD, 13) years; 72.2% of patients were men, and 51.8% had planned valvular surgery. The primary end point occurred in 233 (30.7%) patients assigned to placebo and 227 (30.0%) assigned to n-3-PUFAs (odds ratio, 0.96 [95% CI, 0.77-1.20]; P = .74). None of the secondary end points were significantly different between the placebo and fish oil groups, including postoperative AF that was sustained, symptomatic, or treated (231 [30.5%] vs 224 [29.6%], P = .70) or number of postoperative AF episodes per patient (1 episode: 156 [20.6%] vs 157 [20.7%]; 2 episodes: 59 [7.8%] vs 49 [6.5%]; ≥3 episodes: 18 [2.4%] vs 21 [2.8%]) (P = .73). Supplementation with n-3-PUFAs was generally well tolerated, with no evidence for increased risk of bleeding or serious adverse events. In this large multinational trial among patients undergoing cardiac surgery, perioperative supplementation with n-3-PUFAs, compared with placebo, did not reduce the risk of postoperative AF. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00970489.

  11. Atrial arrhythmias after lung transplant: underlying mechanisms, risk factors, and prognosis.

    PubMed

    Orrego, Carlos M; Cordero-Reyes, Andrea M; Estep, Jerry D; Seethamraju, Harish; Scheinin, Scott; Loebe, Matthias; Torre-Amione, Guillermo

    2014-07-01

    Atrial arrhythmias (AAs) early after lung transplant are frequent and have a significant impact on morbidity and mortality. However, the pathogenesis of AAs after lung transplant remains incompletely understood. In this study we aimed to determine the prevalence of atrial fibrillation (AF) and other AAs, as well as risk factors, clinical outcomes and possible underlying mechanisms associated with AAs after lung transplant. A retrospective analysis was performed on 382 patients who underwent lung transplantation from 2000 to 2010. A 12-lead electrocardiogram (ECG) was obtained and AAs classified as AF and other AAs (atrial flutter [AFL] and supraventricular tachycardia [SVT]). Multivariate logistic regression analysis was performed to determine predictors, and Kaplan-Meier survival curves were constructed. The incidence of AAs was 25%; 17.8% developed AF and 7.6% other AAs (AFL/SVT). The major indication for transplant was idiopathic pulmonary fibrosis (IPF, 35%). Significant predictors of AF were as follows: age; IPF; left atrial enlargement; diastolic dysfunction; and history of coronary artery disease (CAD). Risk factors for other AAs (AFL/SVT) were: age; right ventricle dysfunction; right ventricular enlargement; and elevated right atrial pressure (RAP). One-year mortality was higher in the arrhythmia group (21.5% arrhythmia vs 15.7% no-arrhythmia group; p < 0.05). In addition, patients treated with anti-arrhythmic medications had higher mortality (p < 0.05). AAs are common after lung transplantation. Risk factors for developing either AF or other AAs (AFL/SVT) are different. The development of early AAs post-transplant is associated with prolonged post-operative stay and increased mortality. A rate-control strategy should be used as first-line therapy and anti-arrhythmic agents reserved for those patients who do not respond to the initial treatment. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  12. Effects of chronic omega-3 polyunsaturated fatty acid supplementation on human atrial mechanical function after reversion of atrial arrhythmias to sinus rhythm: reversal of tachycardia-mediated atrial cardiomyopathy with fish oils.

    PubMed

    Kumar, Saurabh; Sutherland, Fiona; Wheeler, Miriam; Heck, Patrick M; Lee, Geoffrey; Teh, Andrew W; Garg, Manohar L; Morgan, John G; Sparks, Paul B

    2011-05-01

    Atrial mechanical stunning is a form of tachycardia-mediated atrial cardiomyopathy that manifests after reversion of persistent atrial arrhythmias to sinus rhythm. This study sought to examine whether chronic omega-3 polyunsaturated fatty acid supplementation with fish oils can reverse atrial mechanical stunning. Patients undergoing reversion of persistent atrial fibrillation (AF) or atrial flutter (AFL) to sinus rhythm were randomized to a control group (n = 26) or an omega-3 group (n = 23). The latter were prescribed 6 g/day of fish oil for ≥1 month prior to the procedure. Parameters of left atrial appendage function were compared immediately before and immediately after reversion. After fish oil intake for a mean of 70 days, the following were noted favoring the omega-3 group among both AF and AFL patients: (1) 2-fold higher serum omega-3 levels (P < .001), (2) less mean decrease in emptying velocity (e.g., AF: 8% vs. 32%, P = .02), (3) less mean decrease in appendage emptying fraction (e.g., AFL: 7% vs. 60%, P = .002), (4) lower incidence of new or increased spontaneous echocardiographic contrast (e.g., AF: 11% vs. 62.5%, P = .003), and (5) lower incidence of atrial mechanical stunning (e.g., AFL: 20% vs. 100%, P = .001). Omega-3 intake conferred protection against stunning in a multivariable analysis (odds ratio 0.18, P = .02). Chronic fish oil ingestion in humans attenuates atrial mechanical stunning after reversion of atrial arrhythmias to sinus rhythm. This suggests that fish oils may target or even reverse underlying cellular and/or structural remodeling that occurs in response to persistent atrial arrhythmias. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  13. Low energy transvenous cardioversion of short duration atrial tachyarrhythmias in humans using a single lead system.

    PubMed

    Heisel, A; Jung, J; Fries, R; Stopp, M; Sen, S; Schieffer, H; Ozbek, C

    1997-01-01

    The purpose of this study was to investigate the efficacy and safety of atrial cardioversion using an endocardial single lead system presently used for ventricular defibrillation. The study population consisted of 26 recipients of an ICD in combination with a conventional endocardial single lead system with the proximal spring electrode as anode in the SVC and the distal as cathode in the apex of the RV. Atrial tachyarrhythmias were induced by right atrial burst pacing. If the arrhythmia sustained > 1 minute, biphasic shocks synchronized with the R wave were delivered using the implanted device, beginning with an energy of 4 J. If 4 J failed to terminate the arrhythmia, energy was increased stepwise, if the first shock was successful, a step-down testing was performed after reinduction of atrial tachyarrhythmias. The mean atrial defibrillation threshold was 2.3 +/- 1.2 J (range, 0.5-5 J). A total of 154 shocks were delivered and no adverse effects were observed. The mean defibrillation threshold for atrial flutter was somewhat lower than that for AF (1.8 +/- 1 J vs 2.7 +/- 1.4 J, P = 0.08). There was no correlation between the atrial defibrillation threshold and a history of previously occurring atrial tachyarrhythmias, the kind of the underlying heart disease, a prescription of antiarrhythmic drugs, the dimension of the LA, the LVEF, or the ventricular DFT. Internal atrial cardioversion of short duration atrial tachyarrhythmias using a transvenous single lead system designed for ventricular defibrillation is feasible and safe at low energies, and may have important clinical applications.

  14. Acute myocardial infarction with changing axis deviation.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2011-07-01

    Changing axis deviation has been rarely reported also during atrial fibrillation or atrial flutter. Changing axis deviation has been rarely reported also during acute myocardial infarction associated with atrial fibrillation. Isolated left posterior hemiblock is a very rare finding but the evidence of transient right axis deviation with a left posterior hemiblock pattern has been reported during acute anterior myocardial infarction as related with significant right coronary artery obstruction and collateral circulation between the left coronary system and the posterior descending artery. Left anterior hemiblock development during acute inferior myocardial infarction can be an indicator of left anterior descending coronary artery lesions, multivessel coronary artery disease, and impaired left ventricular systolic function. We present a case of changing axis deviation in a 62-year-old Italian man with acute myocardial infarction. Also this case focuses attention on changing axis deviation during acute myocardial infarction. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  15. Twelve-lead electrocardiography in the young: physiologic and pathologic abnormalities.

    PubMed

    Kobza, Richard; Cuculi, Florim; Abächerli, Roger; Toggweiler, Stefan; Suter, Yves; Frey, Franz; Schmid, Johann Jakob; Erne, Paul

    2012-12-01

    BACKGROUND/ OBJECTIVE: The purpose of the present study was to analyze the prevalence of physiologic and pathologic ECG abnormalities in a cohort of young conscripts that represents the whole young generation of today. ECGs of all Swiss citizens who underwent conscription for the army during a 29-month period were analyzed manually. ECGs of 43,401 conscripts (mean age 19.2 ± 1.1 years) were analyzed; 158 conscripts were female. Incomplete right bundle branch block was found in 5870 (13.5%) and left anterior fascicular block in 360 (0.83%). First-degree AV block was present in 329 (0.8%) and Mobitz type I (Wenckebach) second-degree AV block in 3 (0.01%). Early repolarization was observed in 1035 (2.4%), T-wave inversion in 39 (0.09%), and minor T-wave changes in 182 (0.42%). Brugada-like abnormalities were observed in 6 (0.01%). None of the conscripts had atrial fibrillation or flutter. ECG abnormalities can be found in a relatively large proportion of young individuals. Incomplete right bundle branch block, left fascicular block, and first-degree AV block are the most frequent findings. No conscript presented with atrial fibrillation or flutter. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. The influence of depression and anxiety symptoms on health-related quality of life in patients with atrial fibrillation and atrial flutter.

    PubMed

    Akintade, Bimbola Fola; Chapa, Deborah; Friedmann, Erika; Thomas, Sue Ann

    2015-01-01

    The health-related quality of life (HRQoL) of patients with atrial fibrillation (AF) and atrial flutter (AFL) is an important issue in cardiovascular health management. Determinants of poor HRQoL of AF/AFL patients require further elucidation. The purpose of this study was to evaluate the influencing factors related to the HRQoL of AF/AFL patients. In 150 consecutively recruited patients in a multicenter, cross-sectional study from April 2010 to February 2011, depression and anxiety were measured with the Beck Depression Inventory II and the State Trait Anxiety Inventory, respectively, whereas HRQoL was assessed with the generic Medical Outcomes Survey 36-Item Short-Form Survey version 2 and the Symptom Checklist. Linear regression modeling was performed to determine predictors of HRQoL among variables, including the patients' age, gender, race, marital status, type of AF/AFL, frequency of AF/AFL symptoms, time since diagnosis, and anxiety and depression symptoms. Female patients with AF/AFL reported poorer physical HRQoL than male patients did (P < .001, R² = 0.391). Symptoms of depression and anxiety were found to be associated with poorer HRQoL (P < .001, R² = 0.482). Anxiety was the strongest predictor of the mental component of the Medical Outcomes Survey 36-Item Short-Form Survey version 2 and the Symptom Checklist. Younger patients had worse AF/AFL-related symptoms and severity than older patients did (P < .001, R² = 0.302). Increased frequency of symptomatic episodes was associated with worse AF/AFL-related symptoms and severity. In conclusion, depression and anxiety symptoms and female gender emerged as clear indicators of poor HRQoL in AF/AFL patients. These risk factors should be used to identify patients who may require additional evaluation and treatment efforts to manage their cardiac conditions or HRQoL. Interventions to improve HRQoL in these individuals require further investigation.

  17. Adoption of direct oral anticoagulants for stroke prevention in atrial fibrillation.

    PubMed

    Baker, D; Wilsmore, B; Narasimhan, S

    2016-07-01

    Direct oral anticoagulants (DOAC) are being increasingly utilised for stroke prevention in atrial fibrillation (AF) and atrial flutter. To analyse the adoption and application of these drugs in a regional hospital inpatient cohort and compare with national prescribing data. Digital medical records identified prescribed anticoagulants for patients admitted with AF and atrial flutter during 2013-2014. Analysis of patient demographics and stroke risk identified trends in prescribing DOAC versus warfarin. For broader comparison, data from the Pharmaceuticals Benefits Scheme were sourced to determine the nation-wide adoption of DOAC. Of the 615 patients identified, 505 (255 in 2013, 250 in 2014) had sufficient records to include in the study. From 2013 to 2014, DOAC prescriptions increased from 9 to 28% (P < 0.001), warfarin and aspirin remained comparatively stable (38-34%, 22-20%), and those prescribed no medication declined (17-8%, P < 0.001). DOAC were prescribed to patients with lower CHA2 DS2 VASc scores than warfarin (3.6 vs 4.4; P = 0.005), lower HAS-BLED scores (1.7 vs 2.3; P < 0.01), higher glomerular filtration rates; 70 vs 63 ml/min; P = 0.002) and younger age (74 vs 77 years; P = 0.006). Nationally, warfarin prescriptions are higher in total numbers but increasing at a slower rate than DOAC, which increased 10-fold (101 158 in 2013, 1 095 985 in 2014). DOAC prescribing grew rapidly from 2013 to 2014, regionally and nationally. Warfarin prescriptions have remained stable, indicating that more patients are being appropriately anticoagulated for AF who previously were not. DOAC were found to be prescribed to patients with lower CHA2 DS2 VASc and HAS-BLED scores, younger age and higher glomerular filtration rates. Aspirin therapy remains over utilised in AF. © 2016 Royal Australasian College of Physicians.

  18. Atrial Arrhythmias in Astronauts - Summary of a NASA Summit

    NASA Technical Reports Server (NTRS)

    Barr, Yael R.; Watkins, Sharmila D.; Polk, J. D.

    2010-01-01

    Background and Problem Definition: To evaluate NASA s current standards and practices related to atrial arrhythmias in astronauts, Space Medicine s Advanced Projects Section at the Johnson Space Center was tasked with organizing a summit to discuss the approach to atrial arrhythmias in the astronaut cohort. Since 1959, 11 cases of atrial fibrillation, atrial flutter, or supraventricular tachycardia have been recorded among active corps crewmembers. Most of the cases were paroxysmal, although a few were sustained. While most of the affected crewmembers were asymptomatic, those slated for long-duration space flight underwent radiofrequency ablation treatment to prevent further episodes of the arrhythmia. The summit was convened to solicit expert opinion on screening, diagnosis, and treatment options, to identify gaps in knowledge, and to propose relevant research initiatives. Summit Meeting Objectives: The Atrial Arrhythmia Summit brought together a panel of six cardiologists, including nationally and internationally renowned leaders in cardiac electrophysiology, exercise physiology, and space flight cardiovascular physiology. The primary objectives of the summit discussions were to evaluate cases of atrial arrhythmia in the astronaut population, to understand the factors that may predispose an individual to this condition, to understand NASA s current capabilities for screening, diagnosis, and treatment, to discuss the risks associated with treatment of crewmembers assigned to long-duration missions or extravehicular activities, and to discuss recommendations for prevention or management of future cases. Summary of Recommendations: The summit panel s recommendations were grouped into seven categories: Epidemiology, Screening, Standards and Selection, Treatment of Atrial Fibrillation Manifesting Preflight, Atrial Fibrillation during Flight, Prevention of Atrial Fibrillation, and Future Research

  19. Ablation for Atrial Fibrillation

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the effectiveness, safety, and costing of ablation methods to manage atrial fibrillation (AF). The ablation methods reviewed were catheter ablation and surgical ablation. Clinical Need Atrial fibrillation is characterized by an irregular, usually rapid, heart rate that limits the ability of the atria to pump blood effectively to the ventricles. Atrial fibrillation can be a primary diagnosis or it may be associated with other diseases, such as high blood pressure, abnormal heart muscle function, chronic lung diseases, and coronary heart disease. The most common symptom of AF is palpitations. Symptoms caused by decreased blood flow include dizziness, fatigue, and shortness of breath. Some patients with AF do not experience any symptoms. According to United States data, the incidence of AF increases with age, with a prevalence of 1 per 200 people aged between 50 and 60 years, and 1 per 10 people aged over 80 years. In 2004, the Institute for Clinical Evaluative Sciences (ICES) estimated that the rate of hospitalization for AF in Canada was 582.7 per 100,000 population. They also reported that of the patients discharged alive, 2.7% were readmitted within 1 year for stroke. One United States prevalence study of AF indicated that the overall prevalence of AF was 0.95%. When the results of this study were extrapolated to the population of Ontario, the prevalence of AF in Ontario is 98,758 for residents aged over 20 years. Currently, the first-line therapy for AF is medical therapy with antiarrhythmic drugs (AADs). There are several AADs available, because there is no one AAD that is effective for all patients. The AADs have critical adverse effects that can aggravate existing arrhythmias. The drug selection process frequently involves trial and error until the patient’s symptoms subside. The Technology Ablation has been frequently described as a “cure” for AF, compared with drug therapy, which controls AF but does not cure it. Ablation involves directing an energy source at cardiac tissue. For instance, radiofrequency energy uses heat to burn tissue near the source of the arrhythmia. The purpose is to create a series of scar tissue, so that the aberrant electrical pathways can no longer exist. Because the pulmonary veins are the predominant source of AF initiation, the primary goal of ablation is to isolate the pulmonary veins from the left atria through the creation of a conduction block. There are 2 methods of ablation: catheter ablation and surgical (operative) ablation. Radiofrequency energy is most commonly used for ablation. Catheter ablation involves inserting a catheter through the femoral vein to access the heart and burn abnormal foci of electrical activity by direct contact or by isolating them from the rest of the atrium. The surgical ablation is performed minimally invasively via direct visualization or with the assistance of a special scope for patients with lone AF. Review Strategy In March 2006, the following databases were searched: Cochrane Library International Agency for Health Technology Assessment (first quarter 2006), Cochrane Database of Systematic Reviews (first quarter 2006), Cochrane Central Register of Controlled Trials (first quarter 2006), MEDLINE (1966 to February 2006), MEDLINE In-Process and Other Non-indexed Citations (1966 to March 1, 2006), and EMBASE (1980 to 2006 week 9). The Medical Advisory Secretariat also searched Medscape on the Internet for recent reports on trials that were unpublished but that were presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials investigating ablation for atrial fibrillation. Search terms included: radiofrequency ablation, catheter ablation and atrial fibrillation. Summary of Findings Sixteen RCTs were identified that compared ablation methods in patients with AF. Two studies were identified that investigated first-line therapy for AF or atrial flutter. Seven other studies examined patients with drug-refractory, lone AF; and the remaining 7 RCTs compared ablation plus heart surgery to heart surgery alone in patients with drug-refractory AF and concomitant heart conditions. First-line Catheter Ablation for Atrial Fibrillation or Atrial Flutter Both studies concluded that catheter ablation was associated with significantly improved long-term freedom from arrhythmias and quality of life compared with medical therapy. These studies included different patient populations (those with AF in one pilot study, and those with atrial flutter in the other). Catheter ablation as first-line treatment is considered experimental at this time. Catheter Ablation Versus Medical Therapy in Patients With Drug-Refractory, Lone Atrial Fibrillation In this review, catheter ablation had success rates (freedom from arrhythmia) that ranged from 42% to 90% (median, 74%) in patients with drug-refractory, lone AF. All 3 of the RCTs comparing catheter ablation to medical therapy in patients with drug-refractory, lone AF found a significant improvement in terms of freedom from arrhythmia over a minimum of 12 months follow-up (P<.05). Ablation Plus Heart Surgery Versus Heart Surgery Alone in Patients With Atrial Fibrillation It is clear that patients with drug-refractory AF who are undergoing concomitant heart surgery (usually mitral valve repair or replacement) benefit significantly from surgical ablation, in terms of long-term freedom from AF, without substantial additional risk compared to open heart surgery alone. This group of patients represents about 1% of the patients with atrial fibrillation, thus the majority of the burden of AF lies within the patients with lone AF (i.e. those not requiring additional heart surgery). Conclusion Catheter ablation appears to be an effective treatment for patients with drug-refractory AF whose treatment alternatives are limited. Ablation technology is continually evolving with increasing success rates associated with the ablation procedure. PMID:23074498

  20. Atrial fibrillation and acute myocardial infarction without significant coronary stenoses associated with subclinical hyperthyroidism and erythrocytosis.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2010-11-05

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that sub-clinical hyperthyroidism is not associated with CHD or mortality from cardiovascular causes but is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. Moreover increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. It has been also reported an acute myocardial infarction with normal coronary arteries associated with iatrogenic hyperthyroidism and with a myocardial bridge too. It has been also reported an acute myocardial infarction without significant coronary stenoses associated with subclinical hyperthyroidism. Furthermore it has been reported that at highly increased hematocrit levels patients may experience hyperviscosity symptoms. We present a case of atrial fibrillation and acute myocardial infarction without significant coronary stenoses associated with subclinical hyperthyroidism and erythrocytosis. Also this case focuses attention on the importance of a correct evaluation of subclinical hyperthyroidism. Copyright © 2008 Elsevier Ireland Ltd. All rights reserved.

  1. Model-based imaging of cardiac electrical function in human atria

    NASA Astrophysics Data System (ADS)

    Modre, Robert; Tilg, Bernhard; Fischer, Gerald; Hanser, Friedrich; Messnarz, Bernd; Schocke, Michael F. H.; Kremser, Christian; Hintringer, Florian; Roithinger, Franz

    2003-05-01

    Noninvasive imaging of electrical function in the human atria is attained by the combination of data from electrocardiographic (ECG) mapping and magnetic resonance imaging (MRI). An anatomical computer model of the individual patient is the basis for our computer-aided diagnosis of cardiac arrhythmias. Three patients suffering from Wolff-Parkinson-White syndrome, from paroxymal atrial fibrillation, and from atrial flutter underwent an electrophysiological study. After successful treatment of the cardiac arrhythmia with invasive catheter technique, pacing protocols with stimuli at several anatomical sites (coronary sinus, left and right pulmonary vein, posterior site of the right atrium, right atrial appendage) were performed. Reconstructed activation time (AT) maps were validated with catheter-based electroanatomical data, with invasively determined pacing sites, and with pacing at anatomical markers. The individual complex anatomical model of the atria of each patient in combination with a high-quality mesh optimization enables accurate AT imaging, resulting in a localization error for the estimated pacing sites within 1 cm. Our findings may have implications for imaging of atrial activity in patients with focal arrhythmias.

  2. Relation of milrinone after surgery for congenital heart disease to significant postoperative tachyarrhythmias.

    PubMed

    Smith, Andrew H; Owen, Jill; Borgman, Kristie Y; Fish, Frank A; Kannankeril, Prince J

    2011-12-01

    Milrinone reduces the risk of low cardiac output syndrome for some pediatric patients after congenital heart surgery. Data from adults undergoing cardiac surgery suggest an association between milrinone and an increased risk of postoperative arrhythmias. We tested the hypothesis that milrinone is an independent risk factor for tachyarrhythmias after congenital heart surgery. Subjects undergoing congenital heart surgery at our institution were consecutively enrolled for 38 months, through September 2010. The data were prospectively collected, including a review of full-disclosure telemetry and the medical records. Within 38 months, 603 enrolled subjects underwent 724 operative procedures. The median age was 5.5 months (range 0.0 to 426), the median weight was 6.0 kg (range 0.7 to 108), and the cohort was 45% female. The overall arrhythmia incidence was 50%, most commonly monomorphic ventricular tachycardia (n = 85, 12%), junctional ectopic tachycardia (n = 69, 10%), accelerated junctional rhythm (n = 58, 8%), and atrial tachyarrhythmias (including atrial fibrillation, atrial flutter, and ectopic or chaotic atrial tachycardia, n = 58, 8%). Multivariate logistic regression analysis demonstrated that independent of age <1 month, the use of cardiopulmonary bypass, the duration of cardiopulmonary bypass, Risk Adjusted classification for Congenital Heart Surgery, version 1, score >3, and the use of epinephrine or dopamine, milrinone use on admission to the cardiac intensive care unit remained independently associated with an increase in the odds of postoperative tachyarrhythmia resulting in an intervention (odds ratio 2.8, 95% confidence interval 1.3 to 6.0, p = 0.007). In conclusion, milrinone use is an independent risk factor for clinically significant tachyarrhythmias in the early postoperative period after congenital heart surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. The Effect of Direct Current Transthoracic Countershock on Human Myocardial Cells Evidenced by Creatine Kinase and Lactic Dehydrogenase Isoenzymes.

    DTIC Science & Technology

    1986-05-01

    effects of DC- countershock on 12 patients without evidence of acute 19 myocardial infarction, following conversion of supra - ventricular tachyarrhythmias...atrial flutter, and supra - ventricular tachycardias. Termination of dysrhythmias--occurs when countershock disrupts a chaotic ectopic rhythm allowing the... catheters in dogs. Circulation, 69(5), 1006-1012. Lown, B., Amarasingham, R., & Neuman, J. (1962). New method for terminating cardiac arrhythmias. Use of

  4. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio

    2015-09-01

    Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Impact of a Novel Catheter Tracking System on Radiation Exposure during the Procedural Phases of Atrial Fibrillation and Flutter Ablation.

    PubMed

    Malliet, Nicolas; Andrade, Jason G; Khairy, Paul; Thanh, Hien Kiem Nguyen; Venier, Sandrine; Dubuc, Marc; Dyrda, Katia; Guerra, Peter; Mondésert, Blandine; Rivard, Léna; Tadros, Rafik; Talajic, Mario; Thibault, Bernard; Roy, Denis; Macle, Laurent

    2015-07-01

    Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (μGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures. ©2015 Wiley Periodicals, Inc.

  6. Impact of dronedarone in atrial fibrillation and flutter on stroke reduction.

    PubMed

    Christiansen, Christine Benn; Torp-Pedersen, Christian; Køber, Lars

    2010-04-07

    Dronedarone has been developed for treatment of atrial fibrillation (AF) or atrial flutter (AFL). It is an amiodarone analogue but noniodinized and without the same adverse effects as amiodarone. This is a review of 7 studies (DAFNE, ADONIS, EURIDIS, ATHENA, ANDROMEDA, ERATO and DIONYSOS) on dronedarone focusing on efficacy, safety and prevention of stroke. There was a dose-finding study (DAFNE), 3 studies focusing on maintenance of sinus rhythm (ADONIS, EURIDIS and DIONYSOS), 1 study focusing on rate control (ERATO) and 2 studies investigating mortality and morbidity (ANDROMEDA and ATHENA). The target dose for dronedarone was established in the DAFNE study to be 400 mg twice daily. Both EURIDIS and ADONIS studies demonstrated that dronedarone was superior to placebo for maintaining sinus rhythm. However, DIONYSOS found that dronedarone is less efficient at maintaining sinus rhythm than amiodarone. ERATO concluded that dronedarone reduces ventricular rate in patients with chronic AF. The ANDROMEDA study in patients with severe heart failure was discontinued because of increased mortality in dronedarone group. Dronedarone reduced cardiovascular hospitalizations and mortality in patients with AF or AFL in the ATHENA trial. Secondly, according to a post hoc analysis a significant reduction in stroke was observed (annual rate 1.2% on dronedarone vs 1.8% on placebo, respectively [hazard ratio 0.66, confidence interval 0.46 to 0.96, P = 0.027]). In total, 54 cases of stroke occurred in 3439 patients (crude rate 1.6%) receiving dronedarone compared to 76 strokes in 3048 patients on placebo (crude rate 2.5%), respectively. Dronedarone can be used for maintenance of sinus rhythm and can reduce stroke in patients with AF who receive usual care, which includes antithrombotic therapy and heart rate control.

  7. Biomarkers of Atrial Cardiopathy and Atrial Fibrillation Detection on Mobile Outpatient Continuous Telemetry After Embolic Stroke of Undetermined Source.

    PubMed

    Sebasigari, Denise; Merkler, Alexander; Guo, Yang; Gialdini, Gino; Kummer, Benjamin; Hemendinger, Morgan; Song, Christopher; Chu, Antony; Cutting, Shawna; Silver, Brian; Elkind, Mitchell S V; Kamel, Hooman; Furie, Karen L; Yaghi, Shadi

    2017-06-01

    Biomarkers of atrial dysfunction or "cardiopathy" are associated with embolic stroke risk. However, it is unclear if this risk is mediated by undiagnosed paroxysmal atrial fibrillation or flutter (AF). We aim to determine whether atrial cardiopathy biomarkers predict AF on continuous heart-rhythm monitoring after embolic stroke of undetermined source (ESUS). This was a single-center retrospective study including all patients with ESUS undergoing 30 days of ambulatory heart-rhythm monitoring to look for AF between January 1, 2013 and December 31, 2015. We reviewed medical records for clinical, radiographic, and cardiac variables. The primary outcome was a new diagnosis of AF detected during heart-rhythm monitoring. The primary predictors were atrial biomarkers: left atrial diameter on echocardiography, P-wave terminal force in electrocardiogram (ECG) lead V1, and P wave - R wave (PR) interval on ECG. A multiple logistic regression model was used to assess the relationship between atrial biomarkers and AF detection. Among 196 eligible patients, 23 (11.7%) were diagnosed with AF. In unadjusted analyses, patients with AF were older (72.4 years versus 61.4 years, P < .001) and had larger left atrial diameter (39.2 mm versus 35.7 mm, P = .03). In a multivariable model, the only predictor of AF was age ≥ 60 years (odds ratio, 3.0; 95% CI, 1.06-8.5; P = .04). Atrial biomarkers were weakly associated with AF after ESUS. This suggests that previously reported associations between these markers and stroke may reflect independent cardiac pathways leading to stroke. Prospective studies are needed to investigate these mechanisms. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Atrial fibrillation.

    PubMed

    Medi, Caroline; Hankey, Graeme J; Freedman, Saul B

    2007-02-19

    The incidence and prevalence of atrial fibrillation are increasing because of both population ageing and an age-adjusted increase in incidence of atrial fibrillation. Deciding between a rate control or rhythm control approach depends on patient age and comorbidities, symptoms and haemodynamic consequences of the arrhythmia, but either approach is acceptable. Digoxin is no longer a first-line drug for rate control: beta-blockers and verapamil and diltiazem control heart rate better during exercise. Anti-arrhythmic drugs have only a 40%-60% success rate of maintaining sinus rhythm at 1 year, and have significant side effects. The selection of optimal antithrombotic prophylaxis depends on the patient's risk of ischaemic stroke and the benefits and risks of long-term warfarin versus aspirin, but is independent of rate or rhythm control strategy. Ischaemic stroke risk is best estimated with the CHADS2 score (Congestive heart failure, Hypertension, Age > or = 75 years, Diabetes, 1 point each; prior Stroke or transient ischaemic attack, 2 points). For patients with valvular atrial fibrillation or a CHADS(2) score > or = 2, anticoagulation with warfarin is recommended (INR 2-3, higher for mechanical valves) unless contraindicated or annual major bleeding risk > 3%. Aspirin or warfarin may be used when the CHADS(2) score = 1. Aspirin, 81-325 mg daily, is recommended in patients with a CHADS(2) score of 0 or if warfarin is contraindicated. Stroke rate is similar for paroxysmal, persistent, and permanent atrial fibrillation, and probably for atrial flutter.

  9. Acute myocardial infarction without significant coronary stenoses associated with endogenous subclinical hyperthyroidism.

    PubMed

    Patanè, Salvatore; Marte, Filippo; Sturiale, Mauro

    2012-04-05

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. Nowadays, there is growing interest regarding endogenous sublinical hyperthyroidism and the cardiovascular system. We present a case of acute myocardial infarction without significant coronary stenoses in a 75-year-old Italian woman with endogenous subclinical hyperthyroidism. Also this case focuses attention on the importance of a correct evaluation of endogenous subclinical hyperthyroidism. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  10. Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study

    PubMed Central

    Madhavan, Malini; Venkatachalam, K. L.; Swale, Matthew J.; DeSimone, Christopher V.; Gard, Joseph J.; Johnson, Susan B.; Suddendorf, Scott H.; Mikell, Susan B.; Ladewig, Dorothy J.; Nosbush, Toni Grabinger; Danielsen, Andrew J.; Knudson, Mark; Asirvatham, Samuel J.

    2016-01-01

    Background Endocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters. Methods Phase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n=10). Phase 2: Percutaneous epicardial ablation of GP was done in 6 dogs using the most efficacious modality identified in phase 1 using 2 novel catheters. Results Phase 1: DC in varying doses [blocking (7 -12μA), electroporation (300-500μA), ablation (3000- 7500μA)], radiofrequency ablation (25–50 W), ultrasound (1.5MHz), and alcohol (2-5ml) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5 and 5/7 GP sites. DC (500–5000μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation (VF) during DC ablation at 5000 μA. Programmed stimulation induced AF in 6 dogs pre-ablation and no atrial arrhythmia in 3, flutter in 1 and AF in 1 post-ablation. Heart rate, blood pressure, effective atrial refractory period and local atrial electrogram amplitude did not change significantly post-ablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium. Conclusion Percutaneous epicardial ablation of GP using direct current and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of atrial fibrillation in order to minimize additional atrial myocardial ablation. PMID:26854009

  11. Temporo-mandibular joint dislocation: an unusual complication of transoesophageal echocardiography.

    PubMed

    Anantharam, Brijesh; Chahal, Navtej; Stephens, Nigel; Senior, Roxy

    2010-03-01

    Temporo-mandibular joint (TMJ) dislocation is an unusual complication of transoesophageal echocardiography (TEE). We report a rare case of bilateral TMJ dislocation in an 84-year-old man prior to DC cardioversion (DCCV) for atrial flutter. Shortly after TEE and DCCV, the patient complained of bilateral facial pain. An orthopantomogram revealed bilateral TMJ dislocation. A closed reduction was performed by maxillo-facial surgeons under intravenous anaesthesia. Although very uncommon, the physician should be aware of the complication and its management.

  12. Insights into new-onset atrial fibrillation following open heart surgery and implications for type II atrial flutter.

    PubMed

    Sadrpour, Shervin A; Srinivasan, Deepa; Bhimani, Ashish A; Lee, Seungyup; Ryu, Kyungmoo; Cakulev, Ivan; Khrestian, Celeen M; Markowitz, Alan H; Waldo, Albert L; Sahadevan, Jayakumar

    2015-12-01

    Postoperative atrial fibrillation (POAF), new-onset AF after open heart surgery (OHS), is thought to be related to pericarditis. Based on AF studies in the canine sterile pericarditis model, we hypothesized that POAF in patients after OHS may be associated with a rapid, regular rhythm in the left atrium (LA), suggestive of an LA driver maintaining AF. The aim of this study was to test the hypothesis that in patients with POAF, atrial electrograms (AEGs) recorded from at least one of the two carefully selected LA sites would manifest a rapid, regular rhythm with AEGs of short cycle length (CL) and constant morphology, but a selected right atrial (RA) site would manifest AEGs with irregular CLs and variable morphology. In 44 patients undergoing OHS, AEGs recorded from the epicardial surface of the RA, the LA portion of Bachmann's bundle, and the posterior LA during sustained AF were analysed for regularity of CL and morphology. Sustained AF occurred in 15 of 44 patients. Atrial electrograms were recorded in 11 of 15 patients; 8 of 11 had rapid, regular activation with constant morphology recorded from at least one LA site; no regular AEG sites were present in 3 of 11 patients. Atrial electrograms recorded during sustained POAF frequently demonstrated rapid, regular activation in at least one LA site, consistent with a driver maintaining AF. Published by Oxford University Press on behalf of the European Society of Cardiology 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  13. Evolving anatomic and electrophysiologic considerations associated with Fontan conversion.

    PubMed

    Mavroudis, Constantine; Backer, Carl Lewis; Deal, Barbara J; Stewart, Robert D; Franklin, Wayne H; Tsao, Sabrina; Ward, Kendra

    2007-01-01

    The principles of Fontan conversion with arrhythmia surgery are to restore the cardiac anatomy by converting the original atriopulmonary connection to a total cavopulmonary artery extracardiac connection and treat the underlying atrial arrhythmias. Successful outcomes of this procedure are dependent on a thorough understanding of several factors: the patient's fundamental diagnosis of single-ventricle anatomy, the resultant cardiac configuration from the original atriopulmonary Fontan connection, right atrial dilatation that leads to atrial flutter or fibrillation, and associated congenital cardiac anomalies. The purpose of this article is to present some of the more challenging anatomic and electrophysiologic problems we have encountered with Fontan conversion and arrhythmia surgery and the innovative solutions we have used to treat them. The cases reviewed herein include: takedown of a Bjork-Fontan modification, right ventricular hypertension and tricuspid regurgitation after atriopulmonary Fontan for pulmonary atresia and intact ventricular septum, takedown of atrioventricular valve isolation patch for right-sided maze procedure, resultant hemodynamic considerations leading to intraoperative pulmonary vein stenosis after Fontan conversion, unwanted inferior vena cava retraction during the extracardiac connection, right atrial cannulation in the presence of a right atrial clot, distended left superior vena cava causing left pulmonary vein stenosis, dropped atrial septum, and the modified right-sided maze procedure for various single-ventricle pathology. Since 1994 we have performed Fontan conversion with arrhythmia surgery on 109 patients with a 0.9% mortality rate. We attribute our program's success in no small measure to the strong collaborative efforts of the cardiothoracic surgery and cardiology teams.

  14. Impact of high-grade Atrioventricular block and cumulative frequent pacing on atrial arrhythmias.

    PubMed

    Wali, Eisha; Deshmukh, Amrish; Bukari, Abdallah; Broman, Michael; Aziz, Zaid; Beaser, Andrew; Upadhyay, Gaurav; Nayak, Hemal M; Tung, Roderick; Ozcan, Cevher

    2018-06-21

    The relationship between high-grade AV block (HGAVB) with cumulative frequent pacing and risk of atrial arrhythmias (AAs) has not been well characterized. We hypothesized HGAVB and pacing may have significant impact on incidence and prevalence of AAs by modulating atrial substrate. To determine impact of HGAVB and pacing on AAs including atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT). All consecutive patients who underwent dual chamber pacemaker implantation for HGAVB from 2005 to 2011 at the University of Chicago were included. AAs and percent of pacing were detected through device interrogation. Patients' data were collected from electronic medical records and clinic visits. A total of 166 patients (mean age 71±15 years; 54% female, 56% African-American) were studied. AF was documented in 27% of patients before pacemaker implantation. During a mean 5.8±2.2 years of follow-up, 47% had device-detected AF, 10% AFL and 26% AT. New-onset AF was documented in 40 of the 122 patients without prior AF (33%). Continuous (≥99%) right ventricular pacing was associated with significantly decreased AF prevalence (34% versus 59%, p = 0.005), and correlated with lower incidence (26% versus 41%, p = 0.22). Pacing suppressed AF in 14% of patients with baseline AF; those patients had lower atrial pacing (3.2% versus 45%, p < 0.0001). Left atrial dilation was the only independent predictor of AF with frequent pacing (p = 0.009). HGAVB is associated with high incidence and prevalence of AAs with and without pacing. Cumulative frequent (≥99%) ventricular pacing reduces risk of AF in patients with HGAVB. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tachyarrhythmias.

    PubMed

    den Dulk, K; Dijkman, B; Pieterse, M; Wellens, H

    1994-11-01

    Mode switching algorithms have been developed to avoid tracking of atrial fibrillation (AF) or flutter (AFL) during DDD(R) pacing. Upon recognition of AF or AFL, the mode is switched to a nontracking, sensor driven mode. The Vitatron Diamond model 800 pacemaker does this on a beat-to-beat basis. Atrial events occurring within a "physiological range" (+/- 15 beats/min) calculated from a running average of the atrial rate are tracked. When atrial events are not tracked the escape interval is either determined by the sensor(s) or by a fallback algorithm thereby preventing large increases in V-V interval during mode switching. Loss of atrioventricular (AV) synchrony by atrial premature beats and after an episode of AF or AFL is prevented by atrial synchronization pulses (ASP), which are delivered after a safe interval (timed out from the sensed premature atrial event) has expired and before delivery of the next ventricular stimulus. We implanted 26 such devices in 18 men and 8 women with symptomatic second- or third-degree AV block and paroxysmal AF or AFL. Their ages ranged from 18-84 years (mean 60), and the follow-up ranged from 2-13 months (mean 8). During pacemaker check-up, exercise testing or 24-hour Holter monitoring one or more episodes of mode switching was documented in 8 patients. In these 8 patients a smooth transition (ventricular rate) from sinus rhythm to AF or AFL was documented on one or more occasions, without inappropriate increase in ventricular rate in the DDDR mode. None of the patients complained of palpitations.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Concomitant atrial fibrillation surgery for people undergoing cardiac surgery

    PubMed Central

    Huffman, Mark D; Karmali, Kunal N; Berendsen, Mark A; Andrei, Adin-Cristian; Kruse, Jane; McCarthy, Patrick M; Malaisrie, S C

    2016-01-01

    Background People with atrial fibrillation (AF) often undergo cardiac surgery for other underlying reasons and are frequently offered concomitant AF surgery to reduce the frequency of short- and long-term AF and improve short- and long-term outcomes. Objectives To assess the effects of concomitant AF surgery among people with AF who are undergoing cardiac surgery on short-term and long-term (12 months or greater) health-related outcomes, health-related quality of life, and costs. Search methods Starting from the year when the first “maze” AF surgery was reported (1987), we searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library (March 2016), MEDLINE Ovid (March 2016), Embase Ovid (March 2016), Web of Science (March 2016), the Database of Abstracts of Reviews of Effects (DARE, April 2015), and Health Technology Assessment Database (HTA, March 2016). We searched trial registers in April 2016. We used no language restrictions. Selection criteria We included randomised controlled trials evaluating the effect of any concomitant AF surgery compared with no AF surgery among adults with preoperative AF, regardless of symptoms, who were undergoing cardiac surgery for another indication. Data collection and analysis Two review authors independently selected studies and extracted data. We evaluated the risk of bias using the Cochrane ‘Risk of bias’ tool. We included outcome data on all-cause and cardiovascular-specific mortality, freedom from atrial fibrillation, flutter, or tachycardia off antiarrhythmic medications, as measured by patient electrocardiographic monitoring greater than three months after the procedure, procedural safety, 30-day rehospitalisation, need for post-discharge direct current cardioversion, health-related quality of life, and direct costs. We calculated risk ratios (RR) for dichotomous data with 95% confidence intervals (CI) using a fixed-effect model when heterogeneity was low (I2 ≤ 50%) and random-effects model when heterogeneity was high (I2 > 50%). We evaluated the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework to create a ‘Summary of findings’ table. Main results We found 34 reports of 22 trials (1899 participants) with five additional ongoing studies and three studies awaiting classification. All included studies were assessed as having high risk of bias across at least one domain. The effect of concomitant AF surgery on all-cause mortality was uncertain when compared with no concomitant AF surgery (7.0% versus 6.6%, RR 1.14, 95% CI 0.81 to 1.59, I2 = 0%, 20 trials, 1829 participants, low-quality evidence), but the intervention increased freedom from atrial fibrillation, atrial flutter, or atrial tachycardia off antiarrhythmic medications > three months (51.0% versus 24.1%, RR 2.04, 95% CI 1.63 to 2.55, I2 = 0%, eight trials, 649 participants, moderate-quality evidence). The effect of concomitant AF surgery on 30-day mortality was uncertain (2.3% versus 3.1%, RR 1.25 95% CI 0.71 to 2.20, I2 = 0%, 18 trials, 1566 participants, low-quality evidence), but the intervention increased the risk of permanent pacemaker implantation (6.0% versus 4.1%, RR 1.69, 95% CI 1.12 to 2.54, I2 = 0%, 18 trials, 1726 participants, moderate-quality evidence). Investigator-defined adverse events, including but limited to, need for surgical re-exploration or mediastinitis, were not routinely reported but were not different between the two groups (other adverse events: 24.8% versus 23.6%, RR 1.07, 95% CI 0.85 to 1.34, I2 = 45%, nine trials, 858 participants), but the quality of this evidence was very low. Authors’ conclusions For patients with AF undergoing cardiac surgery, there is moderate-quality evidence that concomitant AF surgery approximately doubles the risk of freedom from atrial fibrillation, atrial flutter, or atrial tachycardia off anti-arrhythmic drugs while increasing the risk of permanent pacemaker implantation. The effects on mortality are uncertain. Future, high-quality and adequately powered trials will likely affect the confidence on the effect estimates of AF surgery on clinical outcomes. PMID:27551927

  17. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.

    PubMed

    Aryana, Arash; Singh, Sheldon M; Mugnai, Giacomo; de Asmundis, Carlo; Kowalski, Marcin; Pujara, Deep K; Cohen, Andrew I; Singh, Steve K; Fuenzalida, Charles E; Prager, Nelson; Bowers, Mark R; O'Neill, Padraig Gearoid; Brugada, Pedro; d'Avila, André; Chierchia, Gian-Battista

    2016-12-01

    Catheter ablation of atrial fibrillation (CAAF) using the cryoballoon has emerged as an alternate strategy to point-by-point radiofrequency. However, there is little comparative data on long-term durability of pulmonary vein (PV) isolation comparing these two modalities. In this multicenter, retrospective analysis, the incidences/patterns of late PV reconnection following an index CAAF using the second-generation cryoballoon versus open-irrigated, non-force-sensing radiofrequency were examined. Of the 2002 patients who underwent a first-time CAAF, 186/1126 patients (16.5 %) ablated using cryoballoon and 174/876 patients (19.9 %) with non-contact force-guided radiofrequency required a repeat procedure at 11 ± 5 months. During follow-up, the incidence of atrial flutters/tachycardias was lower (19.9 vs. 32.8 %; p = 0.005) and fewer patients exhibited PV reconnection (47.3 vs. 60.9 %; p = 0.007) with cryoballoon versus radiofrequency. Additionally, fewer PVs had reconnected with cryoballoon versus radiofrequency (18.8 vs. 34.6 %; p < 0.001). With cryoballoon, the right inferior (p < 0.001) and left common (p = 0.039) PVs were more likely to exhibit late reconnection, versus the left superior PV with radiofrequency (p = 0.012). However, when comparing the two strategies, the left common PV was more likely to exhibit reconnection with cryoballoon, whereas all other PVs with the exception of the right inferior PV demonstrated a lower reconnection rate with cryoballoon versus radiofrequency. Lastly, in a logistic regression multivariate analysis, cryoballoon ablation and PV ablation time emerged as significant predictors of durable PV isolation at repeat procedure. In this large multicenter, retrospective analysis, CAAF using the second-generation cryoballoon was associated with improved durability of PV isolation compared to open-irrigated, non-force-sensing radiofrequency.

  18. [Analysis of pacemaker ECGs].

    PubMed

    Israel, Carsten W; Ekosso-Ejangue, Lucy; Sheta, Mohamed-Karim

    2015-09-01

    The key to a successful analysis of a pacemaker electrocardiogram (ECG) is the application of the systematic approach used for any other ECG without a pacemaker: analysis of (1) basic rhythm and rate, (2) QRS axis, (3) PQ, QRS and QT intervals, (4) morphology of P waves, QRS, ST segments and T(U) waves and (5) the presence of arrhythmias. If only the most obvious abnormality of a pacemaker ECG is considered, wrong conclusions can easily be drawn. If a systematic approach is skipped it may be overlooked that e.g. atrial pacing is ineffective, the left ventricle is paced instead of the right ventricle, pacing competes with intrinsic conduction or that the atrioventricular (AV) conduction time is programmed too long. Apart from this analysis, a pacemaker ECG which is not clear should be checked for the presence of arrhythmias (e.g. atrial fibrillation, atrial flutter, junctional escape rhythm and endless loop tachycardia), pacemaker malfunction (e.g. atrial or ventricular undersensing or oversensing, atrial or ventricular loss of capture) and activity of specific pacing algorithms, such as automatic mode switching, rate adaptation, AV delay modifying algorithms, reaction to premature ventricular contractions (PVC), safety window pacing, hysteresis and noise mode. A systematic analysis of the pacemaker ECG almost always allows a probable diagnosis of arrhythmias and malfunctions to be made, which can be confirmed by pacemaker control and can often be corrected at the touch of the right button to the patient's benefit.

  19. [Efficacy of Transdermal Patch of Bisoprolol for Paroxysmal Atrial Fibrillation after Open Heart Surgery].

    PubMed

    Yamamoto, Kenji; Yamada, Tomoyuki; Hamuro, Mamoru; Kawatou, Masahide; Enomoto, Sakae

    2017-11-01

    2014 American Association for Thoracic Surgery (AATS) guidelines recommend beta blocker for prevention and management of perioperative atrial fibrillation and flutter for thoracic surgical procedures. In recent years, transdermal patch of bisoprolol (TDPB) has become available in Japan. We examined the efficacy of TDPB for paroxysmal atrial fibrillation (PAF) after open heart surgery. Among 289 patients who had undergone open heart surgery in our hospital from December 2013 to April 2016, 48(16.6%)patients, for whom TDPB was used for PAF, were analyzed retrospectively. The summary of our PAF protocol:HR >80;a sheet of TDPB (4 mg) is pasted, HR≤60;TDPB is removed, HR >140 persisted;another sheet of TDPB is added. Eighteen of the 48 (37.5%) patients recovered sinus rhythm within 24 hours. Six patients( 12.5%), because of persistent tachycardia, shifted to continuous infusion of landiolol. Ten underwent electrical defibrillation during hospitalization. In 3 patients, TDPB was removed due to advanced bradycardia. TDPB could be used safely and feasibly for PAF after open heart surgery.

  20. Intravenous heparin dosing strategy in hospitalized patients with atrial dysrhythmias.

    PubMed

    Roswell, Robert O; Greet, Brian; Shah, Sunny; Bernard, Samuel; Milin, Alexandra; Lobach, Iryna; Guo, Yu; Radford, Martha J; Berger, Jeffrey S

    2016-08-01

    Patients with non-valvular atrial fibrillation (AF) have an elevated stroke risk that is 2-7 times greater than in those without AF. Intravenous unfractionated heparin (UFH) is commonly used for hospitalized patients with atrial fibrillation and atrial flutter (AFL) to prevent stroke. Dosing strategies exist for intravenous anticoagulation in patients with acute coronary syndromes and venous thromboembolic diseases, but there are no data to guide providers on a dosing strategy for intravenous anticoagulation in patients with AF/AFL. 996 hospitalized patients with AF/AFL on UFH were evaluated. Bolus dosing and initial infusion rates of UFH were recorded along with rates of stroke, thromboemobolic events, and bleeding events as defined by the International Society on Thrombosis and Haemostasis criteria. Among 226 patients included in the analysis, 76 bleeding events occurred. Using linear regression analysis, initial rates of heparin infusion ranging from 9.7 to 11.8 units/kilogram/hour (U/kg/h) resulted in activated partial thromboplastin times that were within therapeutic range. The median initial infusion rate in patients with bleeding was 13.3 U/kg/h, while in those without bleeding it was 11.4 U/kg/h; p = 0.012. An initial infusion rate >11.0 U/kg/h yielded an OR 1.95 (1.06-3.59); p = 0.03 for any bleeding event. Using IV heparin boluses neither increased the probability of attaining a therapeutic aPTT (56.1 vs 56.3 %; p = 0.99) nor did it significantly increase bleeding events in the study (35.7 vs 31.3 %; p = 0.48). The results suggest that higher initial rates of heparin are associated with increased bleeding risk. From this dataset, initial heparin infusion rates of 9.7-11.0 U/kg/h without a bolus can result in therapeutic levels of anticoagulation in hospitalized patients with AF/AFL without increasing the risk of bleeding.

  1. Radiofrequency and microwave energy sources in surgical ablation of atrial fibrillation: a comparative analysis.

    PubMed

    Topkara, Veli K; Williams, Mathew R; Barili, Fabio; Bastos, Renata; Liu, Judy F; Liberman, Elyse A; Russo, Mark J; Oz, Mehmet C; Argenziano, Michael

    2006-01-01

    Due to its complexity and risk of bleeding, the Maze III procedure has been largely replaced by surgical ablation for atrial fibrillation (AF) using alternative energy sources. Radiofrequency (RF) and microwave (MW) are the most commonly used energy forms. In this study, we sought to compare these energy modalities in terms of clinical outcomes. Two hundred five patients underwent surgical ablation of AF, from October 1999 to May 2004 at our institution via an endocardial approach. Patients were categorized into 2 groups: RF and MW. Baseline characteristics, operative details, and clinical outcomes were compared between the 2 groups. Rhythm success was defined as freedom from AF and atrial flutter as determined by postoperative electrocardiograms. One hundred twenty patients (58.5%) were ablated using RF, whereas 85 (41.5%) were ablated with MW. Most of the patients had persistent AF in both the RF and MW groups (85.7% versus 80.0%, respectively; P = .363). Intraoperative left atrial size was 6.4 +/- 1.7 cm for the RF group and 6.4 +/- 1.7 cm for the MW group (P = .820). Postoperative rhythm success at 6 and 12 months was 72.4% versus 71.4% (P +/- .611) and 75.0% versus 66.7% (P = .909) for the RF and MW groups, respectively. Hospital length of stay was comparable for both groups (15.4 +/- 14.0 versus 13.3 +/- 13.9 days; P = .307). Postoperative survival at 6 months, 1 year, and 3 years was 90.4%, 89.5%, and 86.1% for RF patients compared to 87.9%, 86.5%, and 84.4% for MW patients, respectively (log rank P = .490). RF and MW energy forms yield comparable postoperative rhythm success, hospital length of stay, and postoperative survival. Both sources are rapid, safe, and effective alternatives to "cut and sew" techniques for surgical treatment of AF.

  2. Non-vitamin K antagonist oral anticoagulants versus warfarin for the prevention of spontaneous echo-contrast and thrombus in patients with atrial fibrillation or flutter undergoing cardioversion: A trans-esophageal echocardiography study.

    PubMed

    Kim, Yun Gi; Choi, Jong-Il; Kim, Mi-Na; Cho, Dong-Hyuk; Oh, Suk-Kyu; Kook, Hyungdon; Park, Hee-Soon; Lee, Kwang No; Baek, Yong-Soo; Roh, Seung-Young; Shim, Jaemin; Park, Seong-Mi; Shim, Wan Joo; Kim, Young-Hoon

    2018-01-01

    Spontaneous echo-contrast (SEC) and thrombus observed in trans-esophageal echocardiography (TEE) is known as a strong surrogate marker for future risk of ischemic stroke in patients with atrial fibrillation (AF) or atrial flutter (AFL). The efficacy of non-vitamin K antagonist oral anticoagulants (NOAC) compared to warfarin to prevent SEC or thrombus in patients with AF or AFL is currently unknown. AF or AFL patients who underwent direct current cardioversion (DCCV) and pre-DCCV TEE evaluation from January 2014 to October 2016 in a single center were analyzed. The prevalence of SEC and thrombus were compared between patients who received NOAC and those who took warfarin. NOAC included direct thrombin inhibitor and factor Xa inhibitors. Among 1,050 patients who were considered for DCCV, 424 patients anticoagulated with warfarin or NOAC underwent TEE prior to DCCV. Eighty patients who were anticoagulated for less than 21 days were excluded. Finally, 344 patients were included for the analysis (180 warfarin users vs. 164 NOAC users). No significant difference in the prevalence of SEC (44.4% vs. 43.9%; p = 0.919), dense SEC (13.9% vs. 15.2%; p = 0.722), or thrombus (2.2% vs. 4.3%; p = 0.281) was observed between the warfarin group and the NOAC group. In multivariate analysis, there was no association between NOAC and risk of SEC (odds ratio [OR]: 1.4, 95% CI: 0.796-2.297, p = 0.265) or thrombus (OR: 3.4, 95% CI: 0.726-16.039, p = 0.120). In conclusion, effectiveness of NOAC is comparable to warfarin in preventing SEC and thrombus in patients with AF or AFL undergoing DCCV. However, numerical increase in the prevalence of thrombus in NOAC group warrants further evaluation.

  3. Non-vitamin K antagonist oral anticoagulants versus warfarin for the prevention of spontaneous echo-contrast and thrombus in patients with atrial fibrillation or flutter undergoing cardioversion: A trans-esophageal echocardiography study

    PubMed Central

    Kim, Yun Gi; Kim, Mi-Na; Cho, Dong-Hyuk; Oh, Suk-Kyu; Kook, Hyungdon; Park, Hee-Soon; Lee, Kwang No; Baek, Yong-Soo; Roh, Seung-Young; Shim, Jaemin; Park, Seong-Mi; Shim, Wan Joo; Kim, Young-Hoon

    2018-01-01

    Spontaneous echo-contrast (SEC) and thrombus observed in trans-esophageal echocardiography (TEE) is known as a strong surrogate marker for future risk of ischemic stroke in patients with atrial fibrillation (AF) or atrial flutter (AFL). The efficacy of non-vitamin K antagonist oral anticoagulants (NOAC) compared to warfarin to prevent SEC or thrombus in patients with AF or AFL is currently unknown. AF or AFL patients who underwent direct current cardioversion (DCCV) and pre-DCCV TEE evaluation from January 2014 to October 2016 in a single center were analyzed. The prevalence of SEC and thrombus were compared between patients who received NOAC and those who took warfarin. NOAC included direct thrombin inhibitor and factor Xa inhibitors. Among 1,050 patients who were considered for DCCV, 424 patients anticoagulated with warfarin or NOAC underwent TEE prior to DCCV. Eighty patients who were anticoagulated for less than 21 days were excluded. Finally, 344 patients were included for the analysis (180 warfarin users vs. 164 NOAC users). No significant difference in the prevalence of SEC (44.4% vs. 43.9%; p = 0.919), dense SEC (13.9% vs. 15.2%; p = 0.722), or thrombus (2.2% vs. 4.3%; p = 0.281) was observed between the warfarin group and the NOAC group. In multivariate analysis, there was no association between NOAC and risk of SEC (odds ratio [OR]: 1.4, 95% CI: 0.796–2.297, p = 0.265) or thrombus (OR: 3.4, 95% CI: 0.726–16.039, p = 0.120). In conclusion, effectiveness of NOAC is comparable to warfarin in preventing SEC and thrombus in patients with AF or AFL undergoing DCCV. However, numerical increase in the prevalence of thrombus in NOAC group warrants further evaluation. PMID:29360845

  4. Feasibility of zero or near zero fluoroscopy during catheter ablation procedures.

    PubMed

    Haegeli, Laurent M; Stutz, Linda; Mohsen, Mohammed; Wolber, Thomas; Brunckhorst, Corinna; On, Chol-Jun; Duru, Firat

    2018-04-03

    Awareness of risks associated with radiation exposure to patients and medical staff has significantly increased. It has been reported before that the use of advanced three-dimensional electro-anatomical mapping (EAM) system significantly reduces fluoroscopy time, however this study aimed for zero or near zero fluoroscopy ablation to assess its feasibility and safety in ablation of atrial fibrillation (AF) and other tachyarrhythmias in a "real world" experience of a single tertiary care center. This was a single-center study where ablation procedures were attempted without fluoroscopy in 34 consecutive patients with different tachyarrhythmias under the support of EAM system. When transseptal puncture (TSP) was needed, it was attempted under the guidance of intracardiac echocardiography (ICE). Among 34 patients consecutively enrolled in this study, 28 (82.4%) patients were referred for radiofrequency ablation (RFA) of AF, 3 (8.8%) patients for ablation of right ventricular outflow tract (RVOT) ventricular extrasystole (VES), 1 (2.9%) patient for ablation of atrioventricular nodal reentry tachycardia (AVNRT), 2 (5.9%) patients for typical atrial flutter ablation. In 21 (62%) patients the entire procedure was carried out without the use of fluoroscopy. Among 28 AF patients, 15 (54%) patients underwent ablation without the use of fluoroscopy and among these 15 patients, 10 (67%) patients required TSP under ICE guidance while 5 (33%) patients the catheters were introduced to left atrium through a patent foramen ovale. In 13 AF patients, fluoroscopy was only required for double TSP. The total procedure time of AF ablation was 130 ± 50 min. All patients referred for atrial flutter, AVNRT, and VES of the RVOT ablation did not require any fluoroscopy. This study demonstrates the feasibility of zero or near zero fluoroscopy procedure including TSP with the support of EAM and ICE guidance in a "real world" experience of a single tertiary care center. When fluoroscopy was required, it was limited to TSP hence keeping the radiation dose very low. .

  5. Plitidepsin Has a Safe Cardiac Profile: A Comprehensive Analysis

    PubMed Central

    Soto-Matos, Arturo; Szyldergemajn, Sergio; Extremera, Sonia; Miguel-Lillo, Bernardo; Alfaro, Vicente; Coronado, Cinthya; Lardelli, Pilar; Roy, Elena; Corrado, Claudia Silvia; Kahatt, Carmen

    2011-01-01

    Plitidepsin is a cyclic depsipeptide of marine origin in clinical development in cancer patients. Previously, some depsipeptides have been linked to increased cardiac toxicity. Clinical databases were searched for cardiac adverse events (CAEs) that occurred in clinical trials with the single-agent plitidepsin. Demographic, clinical and pharmacological variables were explored by univariate and multivariate logistic regression analysis. Forty-six of 578 treated patients (8.0%) had at least one CAE (11 patients (1.9%) with plitidepsin-related CAEs), none with fatal outcome as a direct consequence. The more frequent CAEs were rhythm abnormalities (n = 31; 5.4%), mostly atrial fibrillation/flutter (n = 15; 2.6%). Of note, life-threatening ventricular arrhythmias did not occur. Myocardial injury events (n = 17; 3.0%) included possible ischemic-related and non-ischemic events. Other events (miscellaneous, n = 6; 1.0%) were not related to plitidepsin. Significant associations were found with prostate or pancreas cancer primary diagnosis (p = 0.0017), known baseline cardiac risk factors (p = 0.0072), myalgia present at baseline (p = 0.0140), hemoglobin levels lower than 10 g/dL (p = 0.0208) and grade ≥2 hypokalemia (p = 0.0095). Treatment-related variables (plitidepsin dose, number of cycles, schedule and/or total cumulative dose) were not associated. Electrocardiograms performed before and after plitidepsin administration (n = 136) detected no relevant effect on QTc interval. None of the pharmacokinetic parameters analyzed had a significant impact on the probability of developing a CAE. In conclusion, the most frequent CAE type was atrial fibrillation/atrial flutter, although its frequency was not different to that reported in the age-matched healthy population, while other CAEs types were rare. No dose-cumulative pattern was observed, and no treatment-related variables were associated with CAEs. Relevant risk factors identified were related to the patient’s condition and/or to disease-related characteristics rather than to drug exposure. Therefore, the current analysis supports a safe cardiac risk profile for single-agent plitidepsin in cancer patients. PMID:21747745

  6. Patent foramen ovale closure vs medical therapy for stroke prevention: meta-analysis of randomized trials and review of heterogeneity in meta-analyses.

    PubMed

    Udell, Jacob A; Opotowsky, Alexander R; Khairy, Paul; Silversides, Candice K; Gladstone, David J; O'Gara, Patrick T; Landzberg, Michael J

    2014-10-01

    Patent foramen ovale (PFO) might be a risk factor for unexplained ("cryptogenic") stroke or transient ischemic attack (TIA). We sought to determine the efficacy and safety of transcatheter PFO closure compared with antithrombotic therapy for secondary prevention of cerebrovascular events among patients with cryptogenic stroke. We performed a systematic review and meta-analysis of MedLine and Embase (from inception to March 2013) for randomized controlled trials (RCTs) that compared transcatheter PFO closure with medical therapy in subjects with cryptogenic stroke. Data were independently extracted on trial conduct quality, baseline characteristics, efficacy, and safety events from published articles and appendices. Risk ratios (RRs) and 95% confidence intervals (CIs) for the composite of stroke or TIA, and adverse cardiovascular events including atrial fibrillation/flutter were constructed. Three RCTs of 2303 subjects with previous stroke, TIA, or systemic arterial embolism (mean age, 45.7 years; 47.3% women; mean follow-up, 2.6 years) were included. PFO closure did not significantly reduce the risk of recurrent stroke/TIA (3.7% vs 5.2%; RR, 0.73; 95% CI, 0.50-1.07; P = 0.10); however, an increased risk of incident atrial fibrillation/flutter was detected (3.8% vs 1.0%; RR, 3.67; 95% CI, 1.95-6.89; P < 0.0001). No significant heterogeneity was detected for any end point among subgroups of patients stratified according to age, sex, index cardiovascular event, device type, interatrial shunt size, and presence of an atrial septal aneurysm (all P interactions ≥ 0.09). Meta-analysis of RCTs that assessed transcatheter PFO closure for secondary prevention of cerebrovascular events in subjects with cryptogenic stroke does not demonstrate benefit compared with antithrombotic therapy, and suggests potential risks. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  7. Initial Experience With Ultra High-Density Mapping of Human Right Atria.

    PubMed

    Bollmann, Andreas; Hilbert, Sebastian; John, Silke; Kosiuk, Jedrzej; Hindricks, Gerhard

    2016-02-01

    Recently, an automatic, high-resolution mapping system has been presented to accurately and quickly identify right atrial geometry and activation patterns in animals, but human data are lacking. This study aims to assess the clinical feasibility and accuracy of high-density electroanatomical mapping of various RA arrhythmias. Electroanatomical maps of the RA (35 partial and 24 complete) were created in 23 patients using a novel mini-basket catheter with 64 electrodes and automatic electrogram annotation. Median acquisition time was 6:43 minutes (0:39-23:05 minutes) with shorter times for partial (4.03 ± 4.13 minutes) than for complete maps (9.41 ± 4.92 minutes). During mapping 3,236 (710-16,306) data points were automatically annotated without manual correction. Maps obtained during sinus rhythm created geometry consistent with CT imaging and demonstrated activation originating at the middle to superior crista terminalis, while maps during CS pacing showed right atrial activation beginning at the infero-septal region. Activation patterns were consistent with cavotricuspid isthmus-dependent atrial flutter (n = 4), complex reentry tachycardia (n = 1), or ectopic atrial tachycardia (n = 2). His bundle and fractionated potentials in the slow pathway region were automatically detected in all patients. Ablation of the cavotricuspid isthmus (n = 9), the atrio-ventricular node (n = 2), atrial ectopy (n = 2), and the slow pathway (n = 3) was successfully and safely performed. RA mapping with this automatic high-density mapping system is fast, feasible, and safe. It is possible to reproducibly identify propagation of atrial activation during sinus rhythm, various tachycardias, and also complex reentrant arrhythmias. © 2015 Wiley Periodicals, Inc.

  8. Effect of pilsicainide on dominant frequency in the right and left atria and pulmonary veins during atrial fibrillation: association with its atrial fibrillation terminating effect.

    PubMed

    Horiuchi, Daisuke; Iwasa, Atsushi; Sasaki, Kenichi; Owada, Shingen; Kimura, Masaomi; Sasaki, Shingo; Okumura, Ken

    2009-04-17

    Dominant frequency reflects the peak cycle length of atrial fibrillation. In 34 patients with atrial fibrillation, bipolar electrograms were recorded from multiple atrial sites and pulmonary veins and the effect of pilsicainide, class Ic antiarrhythmic drug, on dominant frequency was examined. At baseline, mean dominant frequencies (Hz) in the right and left atria, coronary sinus and right and left superior pulmonary veins were 5.87 +/- 0.76, 6.08 +/- 0.60, 5.65 +/- 0.95, 6.12 +/- 0.88 and 6.59 +/- 0.89, respectively (P < 0.05, left superior pulmonary vein vs right atrium and coronary sinus). After pilsicainide (1.0 mg/kg/5 min), dominant frequency decreased at all sites in all patients. Atrial fibrillation was terminated at 5.9 +/- 2.2 min in 16 patients (Group A) with a decrease in the average of mean dominant frequencies at all sites from 5.80 +/- 0.72 to 3.57 +/- 0.63 Hz, was converted to atrial flutter at 7.3 +/- 1.4 min in 5 (Group B) with a decrease in the average dominant frequency from 5.83 +/- 0.48 to 3.08 +/- 0.19 Hz, and was not terminated in the other 13 (Group C) despite the average dominant frequency decrease from 6.59 +/- 0.76 to 4.42 +/- 0.52 Hz. In 14 of the 21 Groups A and B patients (67%), mean dominant frequencies at all recording sites were < 4.0 after pilsicainide, while they were < 4.0 in 1 of the 13 Group C patients (8%, P < 0.01). In conclusion, the degree of dominant frequency decrease by pilsicainide is closely related to its atrial fibrillation terminating effect: When dominant frequency in the atria decreases to < 4.0 Hz, atrial fibrillation is terminated with 93% positive and 63% negative predictive values.

  9. Atrial flutter in grown-up congenital heart (GUCH) patients. Clinical characteristics of affected population.

    PubMed

    Li, W; Somerville, J

    2000-09-15

    To define occurrence, lesions and clinical characteristics of grown-up congenital heart (GUCH) patients who develop atrial flutter (AFL). All GUCH patients who presented as inpatients or outpatients with documented sustained AFL between 1996 and 1998 were studied prospectively. Retrospective review of case notes for basic data relating to underlying anomaly, prior surgery and age at onset of AFL, enquiry into events before the first attack. Clinical state was assessed by Ability Index before AFL and at last visit. Designated quaternary service for GUC in a tertiary referral centre. From October 1996 to April 1998, 100 consecutive patients (49 female) aged 17-77 (mean 35) years, who presented to the GUCH Unit at Royal Brompton Hospital with a sustained attack of AEL documented by a 12 lead electrocardiogram were studied. Four basic cardiac anomalies accounted for 75% patients: one ventricle (26), atrial septal defect (ASD) (19), transposition of great arteries (TGA) (17) and Tetralogy of Fallot (13). AFL occurred occasionally in small ventricular septal defect (VSD), congenital corrected TGA (CC-TGA), pulmonary stenosis and pulmonary atresia with or without VSD. 86/100 patients had undergone cardiac surgery: Fontan 19 (22%), reconstruction of right ventricular outflow tract 17 (20%), closure of ASD 15 (17%), Mustard for TGA 13 (15%), and other palliative surgery 22 (26%). AFL occurred in 'natural history' (unoperated) in 14 (14%) mostly in CC-TGA, ASD and Fallot. Age at first attack was 6-64 (mean 28) years with the first attack occurring at younger age after Mustard (22+/-7 years) and Fontan (24+/-7), than in un-operated ASD (46+/-13) and CCTGA (31+/-10). Haemodynamic abnormalities from anatomical causes were present in 62/74 (84%) patients who had undergone reparative surgery and included venous pathway obstruction, pulmonary regurgitation and pulmonary hypertension. Additional factors which could have precipitated AFL in prone patients were present in 63. New symptoms appeared in 96 patients with the first attack of AFL. Ability Index prior to onset in 90 patients who have been followed-up for more than 1 year since the first onset was 1 in 52, 2 in 31, 3 in 6 and 4 in 1 patients. At the last visit (mean time from the first onset 6.6+/-4.7 years), only 9 patients remained with Ability Index 1, 43 in 2, 20 in 3 and 18 in 4 despite return to sinus rhythm. One ventricle heart, ASD, transposition of great arteries and Tetrology of Fallot are the most common underlying anomalies in GUCH patients who develop AFL. It is less commonly seen in unoperated patients. When occurs AFL compromises patients' activities and deteriorates the clinical condition. Residual or developed haemodynamic abnormalities and precipitating factor are often present in this patients, hence full investigation and close follow up are necessary once AFL develops.

  10. [The use of auto mode switching in patients with sick sinus syndrome].

    PubMed

    Vlasínová, J

    2005-01-01

    At present the dual chamber pacing, originally developed for patients with AV blockades, is widely used also for patients with Sick sinus syndrome (tachycardic-bradycardic type). But these patients often cause therapeutical problems to their physicians. In these cases either antiarrhythmic therapy is necessary to prevent recurrent supraventricular tachycardias (which are cause of rapid ventricular pacing) or in the case of failure of AA therapy the pacing mode has to be changed to DDI/R, which excludes physiological VAT pacing. The Auto Mode Switching (AMS) function ensures adequate ventricular pacing rate in the time of SV arrhythmias. Effects of dual chamber pacemakers equipped with AMS were studied in a group of patients with paroxysmal atrial fibrilation and/or atrial flutter. Therapy brings effects in lower of expenses due to less frequent visits at the physician, lower rate of rehospitalizations and lower need for powerful AA therapy.

  11. Association of Burden of Atrial Fibrillation With Risk of Ischemic Stroke in Adults With Paroxysmal Atrial Fibrillation: The KP-RHYTHM Study.

    PubMed

    Go, Alan S; Reynolds, Kristi; Yang, Jingrong; Gupta, Nigel; Lenane, Judith; Sung, Sue Hee; Harrison, Teresa N; Liu, Taylor I; Solomon, Matthew D

    2018-05-16

    Atrial fibrillation is a potent risk factor for stroke, but whether the burden of atrial fibrillation in patients with paroxysmal atrial fibrillation independently influences the risk of thromboembolism remains controversial. To determine if the burden of atrial fibrillation characterized using noninvasive, continuous ambulatory monitoring is associated with the risk of ischemic stroke or arterial thromboembolism in adults with paroxysmal atrial fibrillation. This retrospective cohort study conducted from October 2011 and October 2016 at 2 large integrated health care delivery systems used an extended continuous cardiac monitoring system to identify adults who were found to have paroxysmal atrial fibrillation on 14-day continuous ambulatory electrocardiographic monitoring. The burden of atrial fibrillation was defined as the percentage of analyzable wear time in atrial fibrillation or flutter during the up to 14-day monitoring period. Ischemic stroke and other arterial thromboembolic events occurring while patients were not taking anticoagulation were identified through November 2016 using electronic medical records and were validated by manual review. We evaluated the association of the burden of atrial fibrillation with thromboembolism while not taking anticoagulation after adjusting for the Anticoagulation and Risk Factors in Atrial Fibrillation (ATRIA) or CHA2DS2-VASc stroke risk scores. Among 1965 adults with paroxysmal atrial fibrillation, the mean (SD) age was 69 (11.8) years, 880 (45%) were women, 496 (25%) were persons of color, the median ATRIA stroke risk score was 4 (interquartile range [IQR], 2-7), and the median CHA2DS2-VASc score was 3 (IQR, 1-4). The median burden of atrial fibrillation was 4.4% (IQR ,1.1%-17.23%). Patients with a higher burden of atrial fibrillation were less likely to be women or of Hispanic ethnicity, but had more prior cardioversion attempts compared with those who had a lower burden. After adjusting for either ATRIA or CHA2DS2-VASc stroke risk scores, the highest tertile of atrial fibrillation burden (≥11.4%) was associated with a more than 3-fold higher adjusted rate of thromboembolism while not taking anticoagulants (adjusted hazard ratios, 3.13 [95% CI, 1.50-6.56] and 3.16 [95% CI, 1.51-6.62], respectively) compared with the combined lower 2 tertiles of atrial fibrillation burden. Results were consistent across demographic and clinical subgroups. A greater burden of atrial fibrillation is associated with a higher risk of ischemic stroke independent of known stroke risk factors in adults with paroxysmal atrial fibrillation.

  12. A review of the appropriate and inappropriate use of dronedarone: lessons learned from controlled studies and regulatory submission.

    PubMed

    Naccarelli, Gerald V; Wolbrette, Deborah L; Samii, Soraya; Banchs, Javier E; Penny-Peterson, Erica; Gonzalez, Mario D

    2010-12-01

    Dronedarone is a multichannel blocker with electrophysiologic effects similar to amiodarone. Dronedarone has been documented to prevent atrial fibrillation recurrences and also has efficacy in slowing the ventricular response during episodes of atrial fibrillation. However, in the ANDROMEDA trial, dronedarone was associated with increased mortality when tested in New York Heart Association (NYHA) III/IV patients with left ventricular ejection fractions of less than 35%, who also had a recent hospitalization for decompensated heart failure. When such high-risk patients with heart failure were excluded in the ATHENA trial, dronedarone treatment resulted in a statistical reduction in the composite primary end point of all-cause mortality or cardiovascular hospitalization. In ATHENA, dronedarone reduced cardiovascular hospitalizations even though in the DIONY-SOS trial dronedarone had less effect than amiodarone on suppressing atrial fibrillation recurrences. The most appropriate patients for treatment with dronedarone would be patients with a recent history of paroxysmal or persistent atrial fibrillation/atrial flutter (AF/AFL) that have associated risk factors per the inclusion criteria of ATHENA. Inappropriate patients would be those with class IV heart failure or recently hospitalized for heart failure within the last month from an acute decompensation, the main inclusion criteria in ANDROMEDA. Dronedarone is a novel, multichannel blocking antiarrhythmic agent that may have some pleiotropic effects in addition to its ability to suppress and maintain sinus rhythm and control the rate during AF/AFL recurrences.

  13. A review of the pharmacokinetics, electrophysiology and clinical efficacy of dronedarone.

    PubMed

    Hynes, B John; Luck, Jerry C; Wolbrette, Deborah L; Khan, Mazhar; Naccarelli, Gerald V

    2005-03-01

    The results of major clinical trials and advances in pharmacologic and nonpharmacologic therapies are continuing to alter treatment approaches for both atrial and ventricular arrhythmias. Originally developed as an antianginal medication, amiodarone serves as the most effective antiarrhythmic drug in the treatment of both atrial and life-threatening ventricular arrhythmias. However, amiodarone has complex pharmacokinetics and is associated with serious extracardiac side effects, partially due to the presence of an iodine moiety. With a better understanding of the mechanisms of arrhythmias and antiarrhythmic drugs, new antiarrhythmic agents are currently under development with the hope that they will be more effective and safer than currently available drugs. One such drug that might potentially fulfill this hope is dronedarone. This amiodarone-like compound lacks the iodine moiety, and is similar in structure and electrophysiologic mechanisms of action to amiodarone, to date no evidence of liver, thyroid or pulmonary toxicity has been reported. Three clinical trials demonstrate efficacy in suppressing recurrences of atrial fibrillation and there is also evidence of a rate-slowing benefit during atrial fibrillation/flutter. However, the ANtiarrhythmic trial with DROnedarone in Moderate-to-severe congestive heart failure Evaluating morbidity Decrease (ANDROMEDA) study, performed in patients with left ventricular dysfunction, demonstrated excess noncardiac mortality in patients treated with dronedarone. Although effective in the treatment of atrial fibrillation, the future of this novel amiodarone-like drug remains uncertain until further clarification of the excess mortality in heart failure patients is better studied.

  14. Aeroelastic Tailoring of the NASA Common Research Model via Novel Material and Structural Configurations

    NASA Technical Reports Server (NTRS)

    Jutte, Christine V.; Stanford, Bret K.; Wieseman, Carol D.; Moore, James B.

    2014-01-01

    This work explores the use of tow steered composite laminates, functionally graded metals (FGM), thickness distributions, and curvilinear rib/spar/stringer topologies for aeroelastic tailoring. Parameterized models of the Common Research Model (CRM) wing box have been developed for passive aeroelastic tailoring trade studies. Metrics of interest include the wing weight, the onset of dynamic flutter, and the static aeroelastic stresses. Compared to a baseline structure, the lowest aggregate static wing stresses could be obtained with tow steered skins (47% improvement), and many of these designs could reduce weight as well (up to 14%). For these structures, the trade-off between flutter speed and weight is generally strong, although one case showed both a 100% flutter improvement and a 3.5% weight reduction. Material grading showed no benefit in the skins, but moderate flutter speed improvements (with no weight or stress increase) could be obtained by grading the spars (4.8%) or ribs (3.2%), where the best flutter results were obtained by grading both thickness and material. For the topology work, large weight reductions were obtained by removing an inner spar, and performance was maintained by shifting stringers forward and/or using curvilinear ribs: 5.6% weight reduction, a 13.9% improvement in flutter speed, but a 3.0% increase in stress levels. Flutter resistance was also maintained using straightrotated ribs although the design had a 4.2% lower flutter speed than the curved ribs of similar weight and stress levels were higher. These results will guide the development of a future design optimization scheme established to exploit and combine the individual attributes of these technologies.

  15. Effect of antiarrhythmic therapy with intravenous loading dose of amiodarone: evidence for an altered response in diabetic patients.

    PubMed

    Iervasi, G; Clerico, A; Bonini, R; Nannipieri, M; Manfredi, C; Sabatino, L; Biagini, A; Donato, L

    1998-01-01

    Amiodarone, a potent class III antiarrhythmic agent with adrenergic antagonism properties, is administered increasingly to diabetic patients with cardiac arrhythmias refractory to all other available forms of therapy. Because a large percentage of diabetic patients show a perturbed autonomic regulation of the cardiovascular system, including a pertubed regulation of heart rate, we studied the antiarrhythmic response as well as the early effects (within 5 days) on heart rate of an intravenous amiodarone loading dose in diabetic patients. Seven type II (noninsulin-dependent) diabetic patients (age 64.7 +/- 9.7 years), affected by uncontrolled atrial fibrilation or atrial flutter, were enrolled for the study and a group of 12 well-matched (for age, sex and arrhythmia) nondiabetic patients served as a control group. It was found that before amiodarone administration, nondiabetic patients showed significantly wider variations in the circadian rhythm of heart rate values than diabetic patients (p = 0.0062, unpaired t-test). In all patients but one (who was nondiabetic), amiodarone treatment resulted in a cardioversion to sinus rhythm. After amiodarone administration, nondiabetic patients showed a significantly greater decrease (p = 0.0011) in heart rate values in comparison with the diabetic group (-35% vs. -20% on average, at the end of the study). Furthermore, in nondiabetic patients there was also an earlier significant fall (within the first 4 h after the start of treatment with amiodarone, p < 0.001) in the heart rate values in comparison with diabetic patients, in whom a significant decrease (p < 0.001) was found only at the 4th day. A significant (p = 0.0004), more rapid onset of the antiarrhythmic response to the drug was found in nondiabetic patients (6.8 +/- 6.0 h) in comparison with diabetic patients (98.0 +/- 14.8 h). Our findings suggest that the antiarrhythmic effects of amiodarone in diabetic patients with uncontrolled atrial fibrilation or atrial flutter may be delayed in comparison with nondiabetic patients. This altered response may be (at least in part) due to the diabetic autonomic neuropathy. Our study indicates that the presence of diabetes mellitus always must be taken into account when patients are enrolled for large, prospective, randomized trials, planned to evaluate the antiarrhythmic effects of amiodarone given intravenously.

  16. Advanced electrophysiologic mapping systems: an evidence-based analysis.

    PubMed

    2006-01-01

    To assess the effectiveness, cost-effectiveness, and demand in Ontario for catheter ablation of complex arrhythmias guided by advanced nonfluoroscopy mapping systems. Particular attention was paid to ablation for atrial fibrillation (AF). Tachycardia Tachycardia refers to a diverse group of arrhythmias characterized by heart rates that are greater than 100 beats per minute. It results from abnormal firing of electrical impulses from heart tissues or abnormal electrical pathways in the heart because of scars. Tachycardia may be asymptomatic, or it may adversely affect quality of life owing to symptoms such as palpitations, headaches, shortness of breath, weakness, dizziness, and syncope. Atrial fibrillation, the most common sustained arrhythmia, affects about 99,000 people in Ontario. It is associated with higher morbidity and mortality because of increased risk of stroke, embolism, and congestive heart failure. In atrial fibrillation, most of the abnormal arrhythmogenic foci are located inside the pulmonary veins, although the atrium may also be responsible for triggering or perpetuating atrial fibrillation. Ventricular tachycardia, often found in patients with ischemic heart disease and a history of myocardial infarction, is often life-threatening; it accounts for about 50% of sudden deaths. Treatment of Tachycardia The first line of treatment for tachycardia is antiarrhythmic drugs; for atrial fibrillation, anticoagulation drugs are also used to prevent stroke. For patients refractory to or unable to tolerate antiarrhythmic drugs, ablation of the arrhythmogenic heart tissues is the only option. Surgical ablation such as the Cox-Maze procedure is more invasive. Catheter ablation, involving the delivery of energy (most commonly radiofrequency) via a percutaneous catheter system guided by X-ray fluoroscopy, has been used in place of surgical ablation for many patients. However, this conventional approach in catheter ablation has not been found to be effective for the treatment of complex arrhythmias such as chronic atrial fibrillation or ventricular tachycardia. Advanced nonfluoroscopic mapping systems have been developed for guiding the ablation of these complex arrhythmias. Four nonfluoroscopic advanced mapping systems have been licensed by Health Canada: CARTO EP mapping System (manufactured by Biosense Webster, CA) uses weak magnetic fields and a special mapping/ablation catheter with a magnetic sensor to locate the catheter and reconstruct a 3-dimensional geometry of the heart superimposed with colour-coded electric potential maps to guide ablation. EnSite System (manufactured by Endocardial Solutions Inc., MN) includes a multi-electrode non-contact catheter that conducts simultaneous mapping. A processing unit uses the electrical data to computes more than 3,000 isopotential electrograms that are displayed on a reconstructed 3-dimensional geometry of the heart chamber. The navigational system, EnSite NavX, can be used separately with most mapping catheters. The LocaLisa Intracardiac System (manufactured by Medtronics Inc, MN) is a navigational system that uses an electrical field to locate the mapping catheter. It reconstructs the location of the electrodes on the mapping catheter in 3-dimensional virtual space, thereby enabling an ablation catheter to be directed to the electrode that identifies abnormal electric potential. Polar Constellation Advanced Mapping Catheter System (manufactured by Boston Scientific, MA) is a multielectrode basket catheter with 64 electrodes on 8 splines. Once deployed, each electrode is automatically traced. The information enables a 3-dimensional model of the basket catheter to be computed. Colour-coded activation maps are reconstructed online and displayed on a monitor. By using this catheter, a precise electrical map of the atrium can be obtained in several heartbeats. A systematic search of Cochrane, MEDLINE and EMBASE was conducted to identify studies that compared ablation guided by any of the advanced systems to fluoroscopy-guided ablation of tachycardia. English-language studies with sample sizes greater than or equal to 20 that were published between 2000 and 2005 were included. Observational studies on safety of advanced mapping systems and fluoroscopy were also included. Outcomes of interest were acute success, defined as termination of arrhythmia immediately following ablation; long-term success, defined as being arrhythmia free at follow-up; total procedure time; fluoroscopy time; radiation dose; number of radiofrequency pulses; complications; cost; and the cost-effectiveness ratio. Quality of the individual studies was assessed using established criteria. Quality of the overall evidence was determined by applying the GRADE evaluation system. (3) Qualitative synthesis of the data was performed. Quantitative analysis using Revman 4.2 was performed when appropriate. Quality of the Studies Thirty-four studies met the inclusion criteria. These comprised 18 studies on CARTO (4 randomized controlled trials [RCTs] and 14 non-RCTs), 3 RCTs on EnSite NavX, 4 studies on LocaLisa Navigational System (1 RCT and 3 non-RCTs), 2 studies on EnSite and CARTO, 1 on Polar Constellation basket catheter, and 7 studies on radiation safety. The quality of the studies ranged from moderate to low. Most of the studies had small sample sizes with selection bias, and there was no blinding of patients or care providers in any of the studies. Duration of follow-up ranged from 6 weeks to 29 months, with most having at least 6 months of follow-up. There was heterogeneity with respect to the approach to ablation, definition of success, and drug management before and after the ablation procedure. Evidence is based on a small number of small RCTS and non-RCTS with methodological flaws.Advanced nonfluoroscopy mapping/navigation systems provided real time 3-dimensional images with integration of anatomic and electrical potential information that enable better visualization of areas of interest for ablationAdvanced nonfluoroscopy mapping/navigation systems appear to be safe; they consistently shortened the fluoroscopy duration and radiation exposure.Evidence suggests that nonfluoroscopy mapping and navigation systems may be used as adjuncts to rather than replacements for fluoroscopy in guiding the ablation of complex arrhythmias.Most studies showed a nonsignificant trend toward lower overall failure rate for advanced mapping-guided ablation compared with fluoroscopy-guided mapping.Pooled analyses of small RCTs and non-RCTs that compared fluoroscopy- with nonfluoroscopy-guided ablation of atrial fibrillation and atrial flutter showed that advanced nonfluoroscopy mapping and navigational systems:Yielded acute success rates of 69% to 100%, not significantly different from fluoroscopy ablation.Had overall failure rates at 3 months to 19 months of 1% to 40% (median 25%).Resulted in a 10% relative reduction in overall failure rate for advanced mapping guided-ablation compared to fluoroscopy guided ablation for the treatment of atrial fibrillation.Yielded added benefit over fluoroscopy in guiding the ablation of complex arrhythmia. The advanced systems were shown to reduce the arrhythmia burden and the need for antiarrhythmic drugs in patients with complex arrhythmia who had failed fluoroscopy-guided ablationBased on predominantly observational studies, circumferential PV ablation guided by a nonfluoroscopy system was shown to do the following:Result in freedom from atrial fibrillation (with or without antiarrhythmic drug) in 75% to 95% of patients (median 79%). This effect was maintained up to 28 months.Result in freedom from atrial fibrillation without antiarrhythmic drugs in 47% to 95% of patients (median 63%).Improve patient survival at 28 months after the procedure as compared with drug therapy.Require special skills; patient outcomes are operator dependent, and there is a significant learning curve effect.Complication rates of pulmonary vein ablation guided by an advanced mapping/navigation system ranged from 0% to 10% with a median of 6% during a follow-up period of 6 months to 29 months.The complication rate of the study with the longest follow-up was 8%.The most common complications of advanced catheter-guided ablation were stroke, transient ischemic attack, cardiac tamponade, myocardial infarction, atrial flutter, congestive heart failure, and pulmonary vein stenosis. A small number of cases with fatal atrial-esophageal fistula had been reported and were attributed to the high radiofrequency energy used rather than to the advanced mapping systems. An Ontario-based economic analysis suggests that the cumulative incremental upfront costs of catheter ablation of atrial fibrillation guided by advanced nonfluoroscopy mapping could be recouped in 4.7 years through cost avoidance arising from less need for antiarrhythmic drugs and fewer hospitalization for stroke and heart failure. Expert Opinion Expert consultants to the Medical Advisory Secretariat noted the following: Nonfluoroscopy mapping is not necessary for simple ablation procedures (e.g., typical flutter). However, it is essential in the ablation of complex arrhythmias including these:Symptomatic, drug-refractory atrial fibrillationArrhythmias in people who have had surgery for congenital heart disease (e.g., macro re-entrant tachycardia in people who have had surgery for congenital heart disease).Ventricular tachycardia due to myocardial infarctionAtypical atrial flutterAdvanced mapping systems represent an enabling technology in the ablation of complex arrhythmias. The ablation of these complex cases would not have been feasible or advisable with fluoroscopy-guided ablation and, therefore, comparative studies would not be feasible or ethical in such cases. (ABSTRACT TRUNCATED)

  17. Emergency department presentations for atrial fibrillation and flutter in Alberta: a large population-based study.

    PubMed

    Rosychuk, Rhonda J; Graham, Michelle M; Holroyd, Brian R; Rowe, Brian H

    2017-01-10

    Atrial fibrillation or flutter (AFF) are not infrequent presenting problems in Emergency Departments (ED); however, little is known of the pattern of these presentations. This study provides a description of AFF presentations and outcomes after ED discharge in Alberta. Provincial administrative databases were used to obtain all primary ED encounters for AFF during 1999 to 2011 for patients aged >35 years. Data extracted included demographics, ED visit timing, and subsequent visits to non-ED settings. Analysis included summaries and standardized rates. During the study period, there were 63,398 ED AFF visits from 32,104 distinct adults. Median ages for females and males were 75 and 67 years, respectively; more men (52%) and patients > 65 presented. Overall, the standardized rates remained similar (2.8 per 1,000 over the study period). Specific populations of human services recipients and First Nations had higher ED visit rates for AFF than other groups. Predictable daily, weekly, and monthly trends were observed. The ED visits were followed by numerous subsequent visits in non-ED settings; however, First Nations and women had lower rates of specialist follow-up. Annually, over 5,000 ED presentations of patients experiencing AFF occur in Alberta and admissions proportions are declining. While presentation rates across the province are stable, follow-up with physicians, consultation with cardiologists and health outcomes vary based on socio-economic, age, sex, and First Nations status. Further research is required to understand the causes and consequences of these inequalities and to standardize care.

  18. Postoperative administration of landiolol hydrochloride for patients with supraventricular arrhythmia: the efficacy of sustained intravenous infusion at a low dose.

    PubMed

    Wariishi, Seiichiro; Yamashita, Koichi; Nishimori, Hideaki; Fukutomi, Takashi; Yamamoto, Masaki; Radhakrishnan, Geethalakshmi; Sasaguri, Shiro

    2009-11-01

    The purpose of this study was to investigate the efficacy of landiolol hydrochloride, a short-acting beta(1) blocker, by initiating its administration at a low dose (5 microg kg(-1) min(-1)) in patients with postoperative supraventricular arrhythmia. The efficacy of landiolol was evaluated in 38 patients who, after developing postoperative atrial flutter or fibrillation, with sinus tachycardia and two patients who had a history of paroxysmal atrial fibrillation with frequent atrial extrasystole. The heart rate and blood pressure before and 2 h after the administration of landiolol were compared. A return to the sinus rhythm from supraventricular arrhythmia was noted in 89%. The heart rate was reduced from 137+/-26 bpm (before landiolol administration) to 93+/-18 bpm (2 h after the start of the medication, P<0.01). As an agent to correct an arrhythmic condition, landiolol successfully raised the systolic blood pressure from 108+/-24 mmHg (before medication) to 120+/-19 mmHg (2 h after the medication was started, P<0.05). Continuous intravenous infusion of landiolol at a low dose was found to be effective for postoperative supraventricular arrhythmia.

  19. Left atrial thrombus and dense spontaneous echocardiographic contrast in patients on continuous direct oral anticoagulant therapy undergoing catheter ablation of atrial fibrillation: Comparison of dabigatran, rivaroxaban, and apixaban.

    PubMed

    Wu, Michael; Gabriels, James; Khan, Mohammad; Shaban, Nada; D'Amato, Salvatore; Liu, Christopher F; Markowitz, Steven M; Ip, James E; Thomas, George; Singh, Parmanand; Lerman, Bruce; Patel, Apoor; Cheung, Jim W

    2018-04-01

    Left atrial thrombus (LAT) and dense spontaneous echocardiographic contrast (SEC) detected by transesophageal echocardiography (TEE) in patients on continuous direct oral anticoagulants (DOAC) therapy before catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL) have been described. We sought to compare rates of TEE-detected LAT and dense SEC among patients taking different DOACs. We evaluated 609 consecutive patients from 3 tertiary hospitals (median age 65 years; interquartile range 58-71 years; 436 (72%) men) who were on ≥4 weeks of continuous DOAC therapy (dabigatran, n = 166 [27%]; rivaroxaban, n = 257 [42%]; or apixaban, n = 186 [31%]) undergoing TEE before catheter ablation of AF/AFL. Demographic, clinical, and TEE data were collected for each patient. Despite ≥4 weeks of continuous DOAC therapy, 17 patients (2.8%) had LAT and 15 patients (2.5%) had dense SEC detected by TEE. The rates of LAT were 3.0%, 3.5%, and 1.6% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .482). The rates of dense SEC were 1.2%, 3.5%, and 2.2% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .299). Congestive heart failure (odds ratio 4.4; 95% confidence interval 1.6-12; P = .003) and moderate/severe left atrial enlargement (odds ratio 3.1; 95% confidence interval 1.1-8.6; P = .026) were independent predictors of LAT. In this study, ∼3% of patients on continuous DOAC therapy had LAT detected before catheter ablation of AF/AFL. Specific DOAC therapy did not significantly affect the rates of LAT detection. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Cost-effectiveness of dronedarone and standard of care compared with standard of care alone: US results of an ATHENA lifetime model.

    PubMed

    Reynolds, Matthew R; Nilsson, Jonas; Akerborg, Orjan; Jhaveri, Mehul; Lindgren, Peter

    2013-01-01

    The first antiarrhythmic drug to demonstrate a reduced rate of cardiovascular hospitalization in atrial fibrillation/flutter (AF/AFL) patients was dronedarone in a placebo-controlled, double-blind, parallel arm Trial to assess the efficacy of dronedarone 400 mg bid for the prevention of cardiovascular Hospitalization or death from any cause in patiENts with Atrial fibrillation/atrial flutter (ATHENA trial). The potential cost-effectiveness of dronedarone in this patient population has not been reported in a US context. This study assesses the cost-effectiveness of dronedarone from a US health care payers' perspective. ATHENA patient data were applied to a patient-level health state transition model. Probabilities of health state transitions were derived from ATHENA and published data. Associated costs used in the model (2010 values) were obtained from published sources when trial data were not available. The base-case model assumed that patients were treated with dronedarone for the duration of ATHENA (mean 21 months) and were followed over a lifetime. Cost-effectiveness, from the payers' perspective, was determined using a Monte Carlo microsimulation (1 million fictitious patients). Dronedarone plus standard care provided 0.13 life years gained (LYG), and 0.11 quality-adjusted life years (QALYs), over standard care alone; cost/QALY was $19,520 and cost/LYG was $16,930. Compared to lower risk patients, patients at higher risk of stroke (Congestive heart failure, history of Hypertension, Age ≥ 75 years, Diabetes mellitus, and past history of Stroke or transient ischemic attack (CHADS(2)) scores 3-6 versus 0) had a lower cost/QALY ($9580-$16,000 versus $26,450). Cost/QALY was highest in scenarios assuming lifetime dronedarone therapy, no cardiovascular mortality benefit, no cost associated with AF/AFL recurrence on standard care, and when discounting of 5% was compared with 0%. By extrapolating the results of a large, multicenter, randomized clinical trial (ATHENA), this model suggests that dronedarone is a cost-effective treatment option for approved indications (paroxysmal/persistent AF/AFL) in the US.

  1. The effects of rotational flow, viscosity, thickness, and shape on transonic flutter dip phenomena

    NASA Technical Reports Server (NTRS)

    Reddy, T. S. R.; Srivastava, Rakesh; Kaza, Krishna Rao V.

    1988-01-01

    The transonic flutter dip phenomena on thin airfoils, which are employed for propfan blades, is investigated using an integrated Euler/Navier-Stokes code and a two degrees of freedom typical section structural model. As a part of the code validation, the flutter characteristics of the NACA 64A010 airfoil are also investigated. In addition, the effects of artificial dissipation models, rotational flow, initial conditions, mean angle of attack, viscosity, airfoil thickness and shape on flutter are investigated. The results obtained with a Euler code for the NACA 64A010 airfoil are in reasonable agreement with published results obtained by using transonic small disturbance and Euler codes. The two artificial dissipation models, one based on the local pressure gradient scaled by a common factor and the other based on the local pressure gradient scaled by a spectral radius, predicted the same flutter speeds except in the recovery region for the case studied. The effects of rotational flow, initial conditions, mean angle of attack, and viscosity for the Reynold's number studied seem to be negligible or small on the minima of the flutter dip.

  2. Interest of waiting time for spontaneous early reconnection after cavotricuspid isthmus ablation: A monocentric randomized trial.

    PubMed

    Marchandise, Sébastien; Scavée, Christophe; Barbraud, Cynthia; de Meester de Ravenstein, Christophe; Balola Bagalwa, Mittérand; Goesaert, Cédric; Reis-Pinheiro, Ivone; le Polain de Waroux, Jean-Benoit

    2017-12-01

    The aim of this study was to determine the rate of recurrent atrial flutter (AFl) after isolated cavotricuspid isthmus (CTI) ablation and to evaluate the impact of a waiting period with the search for early resumption of the CTI block on the long-term outcome. Three hundred and nineteen consecutive patients referred for typical AFl ablation were randomly assigned to CTI ablation with continuous reevaluation of the CTI block during 30 minutes and early reablation if needed (waiting time [WT] + group, n  =  155) or to CTI ablation with no waiting period after proven bidirectional CTI block (WT - group, n  =  164). All patients were regularly followed-up. In the WT+ group, 10 patients (6%) presented a recovery across the CTI (time to recovery: 17 ± 7') and were reablated at the end of the waiting period. After a median follow-up of 21 months, the rate of recurrent AFl was significantly higher in the WT - group as compared to the WT+ group (11.6% [19/164] vs 2.5% [4/155], respectively; P  =  0.007). However, no significant differences in the subsequent rate of AF were observed between the two groups (29% [WT -] vs 32% [WT+], P  =  0.66). During the follow-up, 28 patients from the WT - group underwent a second ablation procedure (16 AFl redo and 12 AF ablation) versus 10 patients form the WT+ group (three AFl redo and seven AF ablation). Waiting 30 minutes after CTI ablation to check for early resumption and early reablation allows for decreasing significantly the rate of recurrent atrial flutter. © 2017 Wiley Periodicals, Inc.

  3. High correlation of estimated local conduction velocity with natural logarithm of bipolar electrogram amplitude in the reentry circuit of atrial flutter.

    PubMed

    Itoh, Taihei; Kimura, Masaomi; Sasaki, Shingo; Owada, Shingen; Horiuchi, Daisuke; Sasaki, Kenichi; Ishida, Yuji; Takahiko, Kinjo; Okumura, Ken

    2014-04-01

    Low conduction velocity (CV) in the area showing low electrogram amplitude (EA) is characteristic of reentry circuit of atypical atrial flutter (AFL). The quantitative relationship between CV and EA remains unclear. We characterized AFL reentry circuit in the right atrium (RA), focusing on the relationship between local CV and bipolar EA on the circuit. We investigated 26 RA AFL (10 with typical AFL; 10 atypical incisional AFL; 6 atypical nonincisional AFL) using CARTO system. By referring to isochronal and propagation maps delineated during AFL, points activated faster on the circuit were selected (median, 7 per circuit). At the 196 selected points obtained from all patients, local CV measured between the adjacent points and bipolar EA were analyzed. There was a highly significant correlation between local CV and natural logarithm of EA (lnEA) (R(2) = 0.809, P < 0.001). Among 26 AFL, linear regression analysis of mean CV, calculated by dividing circuit length (152.3 ± 41.7 mm) by tachycardia cycle length (TCL) (median 246 msec), and mean lnEA, calculated by dividing area under curve of lnEA during one tachycardia cycle by TCL, showed y = 0.695 + 0.191x (where: y = mean CV, x = lnEA; R(2) = 0.993, P < 0.001). Local CV estimated from EA with the use of this formula showed a highly significant linear correlation with that measured by the map (R(2) = 0.809, P < 0.001). The lnEA and estimated local CV show a highly positive linear correlation. CV is possibly estimated by EA measured by CARTO mapping. © 2013 Wiley Periodicals, Inc.

  4. Implementation of an emergency department atrial fibrillation and flutter pathway improves rates of appropriate anticoagulation, reduces length of stay and thirty-day revisit rates for congestive heart failure.

    PubMed

    Barbic, David; DeWitt, Chris; Harris, Devin; Stenstrom, Robert; Grafstein, Eric; Wu, Crane; Vadeanu, Cristian; Heilbron, Brett; Haaf, Jenelle; Tung, Stanley; Kalla, Dan; Marsden, Julian; Christenson, Jim; Scheuermeyer, Frank

    2018-05-01

    An evidence-based emergency department (ED) atrial fibrillation and flutter (AFF) pathway was developed to improve care. The primary objective was to measure rates of new anticoagulation (AC) on ED discharge for AFF patients who were not AC correctly upon presentation. This is a pre-post evaluation from April to December 2013 measuring the impact of our pathway on rates of new AC and other performance measures in patients with uncomplicated AFF solely managed by emergency physicians. A standardized chart review identified demographics, comorbidities, and ED treatments. The primary outcome was the rate of new AC. Secondary outcomes were ED length of stay (LOS), referrals to AFF clinic, ED revisit rates, and 30-day rates of return visits for congestive heart failure (CHF), stroke, major bleeding, and death. ED AFF patients totalling 301 (129 pre-pathway [PRE]; 172 post-pathway [POST]) were included; baseline demographics were similar between groups. The rates of AC at ED presentation were 18.6% (PRE) and 19.7% (POST). The rates of new AC on ED discharge were 48.6 % PRE (95% confidence interval [CI] 42.1%-55.1%) and 70.2% POST (62.1%-78.3%) (20.6% [p<0.01; 15.1-26.3]). Median ED LOS decreased from 262 to 218 minutes (44 minutes [p<0.03; 36.2-51.8]). Thirty-day rates of ED revisits for CHF decreased from 13.2% to 2.3% (10.9%; p<0.01; 8.1%-13.7%), and rates of other measures were similar. The evidence-based pathway led to an improvement in the rate of patients with new AC upon discharge, a reduction in ED LOS, and decreased revisit rates for CHF.

  5. Geographic clustering of emergency department presentations for atrial fibrillation and flutter in Alberta, Canada.

    PubMed

    Rosychuk, Rhonda J; Mariathas, Hensley H; Graham, Michelle M; Holroyd, Brian R; Rowe, Brian H

    2015-08-01

    Atrial fibrillation and flutter (AFF) are the most common arrhythmias seen in the outpatient setting, and they affect more than 300,000 adult Canadians. The aims of this study were to examine temporal and geographic trends in emergency department (ED) presentations made by adults (age ≥ 35 years) for AFF in Alberta, Canada, from 1999 to 2011. Statistical disease cluster detection techniques were used to identify geographic areas with higher numbers of individuals presenting with AFF and higher numbers of ED presentations for AFF than expected by chance alone. Geographic clusters of individuals with stroke or heart failure follow-up within 365 days of ED presentations for AFF were also identified. All ED presentations for AFF made by individuals aged ≥35 years were extracted from Alberta's Ambulatory Care Classification System. The Alberta Health Care Insurance Plan provided population counts and demographics for the patients presenting (age, sex, year, geographic unit). The Physician Claims File provided non-ED physician claims data after a patient's ED presentation. Statistical analyses included numerical and graphical summaries, directly standardized rates, and statistical disease cluster detection tests. During 12 years, there were 63,395 ED presentations for AFF made by 32,101 individuals. Standardized rates remained relatively stable over time, at about two per 1,000 for individuals presenting to the ED for AFF and about three per 1,000 for ED presentations for AFF. The northern and southeastern parts of the province were identified as clusters of individuals presenting for AFF, and ED presentations for AFF, and several of the areas demonstrated clusters in multiple years. Further, several of the geographic clusters were also identified as potential clusters for stroke or heart failure within 365 days after the ED presentations for AFF. This population-based study spanned 12 fiscal years and showed variations in the number of people presenting to EDs for AFF and the number of ED presentations for AFF over geography. The potential clusters identified may represent geographic areas with higher disease severity or a lower availability of non-ED health services. The clusters are not all likely to have occurred by chance, and further investigation and intervention could occur to reduce ED presentations for AFF. © 2015 by the Society for Academic Emergency Medicine.

  6. A Clinical Feasibility Study of Atrial and Ventricular Electromechanical Wave Imaging

    PubMed Central

    Provost, Jean; Gambhir, Alok; Vest, John; Garan, Hasan; Konofagou, Elisa E.

    2014-01-01

    Background Cardiac Resynchronization Therapy (CRT) and atrial ablation currently lack a noninvasive imaging modality for reliable treatment planning and monitoring. Electromechanical Wave Imaging (EWI) is an ultrasound-based method that has previously been shown to be capable of noninvasively and transmurally mapping the activation sequence of the heart in animal studies by estimating and imaging the electromechanical wave, i.e., the transient strains occurring in response to the electrical activation, at both very high temporal and spatial resolution. Objective Demonstrate the feasibility of noninvasive transthoracic EWI for mapping the activation sequence during different cardiac rhythms in humans. Methods EWI was performed in CRT patients with a left bundle-branch block (LBBB), during sinus rhythm, left-ventricular pacing, and right-ventricular pacing and in atrial flutter (AFL) patients before intervention and correlated with results from invasive intracardiac electrical mapping studies during intervention. Additionally, the feasibility of single-heartbeat EWI at 2000 frames/s, is demonstrated in humans for the first time in a subject with both AFL and right bundle-branch-block. Results The electromechanical activation maps demonstrated the capability of EWI to localize the pacing sites and characterize the LBBB activation sequence transmurally in CRT patients. In AFL patients, the propagation patterns obtained with EWI were in agreement with results obtained from invasive intracardiac mapping studies. Conclusion Our findings demonstrate the potential capability of EWI to aid in monitoring and follow-up of patients undergoing CRT pacing therapy and atrial ablation with preliminary validation in vivo. PMID:23454060

  7. Activation of generalised inflammatory reaction following electrical cardioversion.

    PubMed

    Gajek, Jacek; Zyśko, Dorota; Mysiak, Andrzej; Mazurek, Walentyna

    2004-09-01

    Restoration of sinus rhythm in patients with atrial fibrillation (AF) is associated with an increased risk of thrombo-embolic complications due to delayed return of the left atrial and left atrial appendage systolic function. Direct current cardioversion (DC), used for AF termination, may cause myocardial injury and subsequent activation of inflammatory response. A C-reactive protein (CRP) is a non-specific marker of inflammation. To examine the effects of external DC of AF or atrial flutter (AFlut) on inflammatory processes. The study group consisted of 35 patients (20 females and 15 males, mean age 67.9+/-9.7 years, range 46-83 years) with paroxysmal or persistent AF/AFlut who underwent elective DC. CRP plasma concentration was measured before and 24 hours after DC. The mean total DC energy was 431.2 J. CRP plasma concentration increased significantly following DC - from 3.9+/-3.4 ng/ml before DC to 7.2+/-6.7 ng/ml after DC (p<0.0001). CRP level correlated with body mass index (r=0.34, p<0.05), however, this correlation became non-significant after inclusion of the presence of diabetes into the statistical model. There was also a positive correlation between CRP values before and after DC (r=0.72, p<0.0001). No correlation between CRP and gender, total power of DC nor the number of DC shocks was detected. External DC of AF/Aflut causes activation of inflammatory processes measured as a significant increase in the CRP plasma concentration.

  8. Causes and Predictors of Readmission in Patients With Atrial Fibrillation Undergoing Catheter Ablation: A National Population-Based Cohort Study.

    PubMed

    Arora, Shilpkumar; Lahewala, Sopan; Tripathi, Byomesh; Mehta, Varshil; Kumar, Varun; Chandramohan, Divya; Lemor, Alejandro; Dave, Mihir; Patel, Nileshkumar; Patel, Nilay V; Palamaner Subash Shantha, Ghanshyam; Viles-Gonzalez, Juan; Deshmukh, Abhishek

    2018-06-15

    Reducing readmission after catheter ablation (CA) in atrial fibrillation (AF) is important. We utilized National Readmission Data (NRD) 2010-2014. AF was identified by International Classification of Diseases, Ninth Edition, Clinical Modification (ICD-9-CM) diagnostic code 427.31 in the primary field, while first CA of AF was identified via ICD-9 -procedure code 37.34. Any admission within 30 or 90 days of index admission was considered a readmission. Cox proportional hazard regression was used to adjust for confounders. The primary outcomes were 30- and 90-day readmissions and the secondary outcome was AF recurrence. In total, 1 128 372 patients with AF were identified from January 1, 2010 to September 30, 2014. Of which 37 360 (3.3%) underwent CA. Patients aged ≥65 years and female sex were less likely to receive CA for AF. Overall, 10.9% and 16.5% of CA patients were readmitted within 30 and 90 days post-CA, respectively. Most common causes of readmissions were arrhythmia (AF, atrial flutter), heart failure, pulmonary causes (pneumonia, chronic obstructive pulmonary disease) and bleeding complications (gastrointestinal bleed, intracranial hemorrhage). Patients with diabetes mellitus, heart failure, coronary artery disease (CAD), chronic pulmonary and kidney disease, prior stroke/transient ischemic attack (TIA), female sex, length of stay ≥2 and disposition to the facility were prone to higher 30- and 90-day readmissions post-CA. Predictors of increase in AF recurrence post-CA were female sex, diabetes mellitus, chronic pulmonary disease, and length of stay ≥2. Trends of 90-day readmission and AF recurrence were found to improve over the study period. We identified several demographic and clinical factors associated with the use of CA in AF, and short-term outcomes of the same, which could potentially help in the patient selection and improve outcomes. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  9. Analysis of stall flutter of a helicopter radar blade

    NASA Technical Reports Server (NTRS)

    Crimi, P.

    1973-01-01

    A study of rotor blade aeroelastic stability was carried out, using an analytic model of a two-dimensional airfoil undergoing dynamic stall and an elastomechanical representation including flapping, flapwise bending and torsional degrees of freedom. Results for a hovering rotor demonstrated that the models used are capable of reproducing both classical and stall flutter. The minimum rotor speed for the occurrence of stall flutter in hover, was found to be determined from coupling between torsion and flapping. Instabilities analogous to both classical and stall flutter were found to occur in forward flight. However, the large stall-related torsional oscillations which commonly limit aircraft forward speed appear to be the response to rapid changes in aerodynamic moment which accompany stall and unstall, rather than the result of an aeroelastic instability. The severity of stall-related instabilities and response was found to depend to some extent on linear stability. Increasing linear stability lessens the susceptibility to stall flutter and reduced the magnitude of the torsional response to stall and unstall.

  10. [Auricular arrhythmia in Steinert's myotonia. Apropos of a case with a familial study].

    PubMed

    Chagnon, A; Vidal, M E

    1983-02-24

    A case of bradycardia-tachycardia syndrome leading to the late discovery of Steinert syndrome is reported. There is a discrepancy between the frequency of the main features of the bradycardia-tachycardia syndrome (sinoatrial block and atrial flutter in our observation) usually reported in Steinert disease and the fact that no case similar to ours seems to have yet been reported; this suggests definite underrating. Insertion of a pacemaker should avoid sudden death from a conduction disturbance. The heart should be carefully monitored in patients with myotonic dystrophy; conversely, this diagnosis should be considered in the etiologic diagnosis of myocardiopathies.

  11. POLYURIA IN PAROXYSMAL TACHYCARDIA AND PAROXYSMAL ATRIAL FLUTTER AND FIBRILLATION

    PubMed Central

    Wood, Paul

    1963-01-01

    When Paul Wood spoke about this to the British Cardiac Society in 1961, we were impressed by the originality of his work on a subject that so many had noticed but failed to investigate. A few months before his death in July 1962, when I asked him if his paper was ready for the journal, he said that he had not yet been able to get all the evidence he hoped for to establish the full explanation. Unfortunately, he had not the time to complete this. I have, therefore, tried to set out as clearly as possible the stage that he had reached. Maurice Campbell Images PMID:14001750

  12. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR

  13. Atrial Fibrillation and Pulmonary Venous Electrical Conduction Recovery After Full Surgical Resection and Anastomosis of the Pulmonary Veins: Insights From Follow-Up and Ablation Procedures in Lung Transplant Recipients.

    PubMed

    Hussein, Ayman A; Panchabhai, Tanmay S; Budev, Marie M; Tarakji, Khaldoun; Barakat, Amr F; Saliba, Walid; Lindsay, Bruce; Wazni, Oussama M

    2017-06-01

    The authors report their experience with atrial fibrillation (AF) rates and ablation findings in lung transplant recipients. Pulmonary venous (PV) conduction recovery accounts for most failed atrial fibrillation (AF) catheter ablation procedures. Lung transplantation involves full surgical resection and replacement of the recipient's PVs with donor's PVs, which may represent the ultimate PV ablation. They followed 755 consecutive lung transplant recipients categorized based on transplant status (unilateral vs. bilateral) and pre-transplant AF. In patients without pre-transplant AF (n = 704), late AF (beyond 6 months after transplant) occurred in 2.5% and 3.3% of unilateral or bilateral lung transplants, respectively. In patients with pre-transplant AF (n = 51), AF recurred in 19.4% and 25.0% of bilateral and unilateral transplants, respectively. In a subset of patients who underwent left atrial ablations after transplant for recurrent refractory AF (n = 8), PV conduction recovery across the surgical anastomoses lines was observed in 22 of 26 previously disconnected PVs. Conduction recovery was observed in ≥1 vein in all but 1 patient. Re-isolation of the veins with additional substrate modification/flutter ablations successfully restored and maintained sinus rhythm in 7 of 8 patients. In lung transplant recipients who undergo full surgical resection of the PVs, a prior history of AF was associated with late AF, regardless of whether patients underwent single or bilateral lung transplantation. PV conduction recovery still occurred and was observed in most patients who underwent left atrial ablation procedures for recurrent AF. Copyright © 2017. Published by Elsevier Inc.

  14. A Simple Score That Predicts Paroxysmal Atrial Fibrillation on Outpatient Cardiac Monitoring after Embolic Stroke of Unknown Source.

    PubMed

    Ricci, Brittany; Chang, Andrew D; Hemendinger, Morgan; Dakay, Katarina; Cutting, Shawna; Burton, Tina; Mac Grory, Brian; Narwal, Priya; Song, Christopher; Chu, Antony; Mehanna, Emile; McTaggart, Ryan; Jayaraman, Mahesh; Furie, Karen; Yaghi, Shadi

    2018-06-01

    Occult paroxysmal atrial fibrillation (AF) is detected in 16%-30% of patients with embolic stroke of unknown source (ESUS). The identification of AF predictors on outpatient cardiac monitoring can help guide clinicians decide on a duration or method of cardiac monitoring after ESUS. We included all patients with ESUS who underwent an inpatient diagnostic evaluation and outpatient cardiac monitoring between January 1, 2013, and December 31, 2016. Patients were divided into 2 groups based on detection of AF or atrial flutter during monitoring. We compared demographic data, clinical risk factors, and cardiac biomarkers between the 2 groups. Multivariable logistic regression was used to determine predictors of AF. We identified 296 consecutive patients during the study period; 38 (12.8%) patients had AF detected on outpatient cardiac monitoring. In a multivariable regression analysis, advanced age (ages 65-74: odds ratio [OR] 2.36, 95% confidence interval [CI] .85-6.52; ages 75 or older: OR 4.08, 95% CI 1.58-10.52) and moderate-to-severe left atrial enlargement (OR 4.66, 95% CI 1.79-12.12) were predictors of AF on outpatient monitoring. We developed the Brown ESUS-AF score: age (65-74 years: 1 point, 75 years or older: 2 points) and left atrial enlargement (moderate or severe: 2 points) with good prediction of AF (area under the curve .725) and was internally validated using bootstrapping. The percentage of patients with AF detected in each score category were as follows: 0: 4.2%; 1: 14.8%; 2: 20.8%; 3: 22.2%; 4: 55.6%. The Brown ESUS-AF score predicts AF on prolonged outpatient monitoring after ESUS. More studies are needed to externally validate our findings. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  15. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    PubMed

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  16. Internal Structural Design of the Common Research Model Wing Box for Aeroelastic Tailoring

    NASA Technical Reports Server (NTRS)

    Jutte, Christine V.; Stanford, Bret K.; Wieseman, Carol D.

    2015-01-01

    This work explores the use of alternative internal structural designs within a full-scale wing box structure for aeroelastic tailoring, with a focus on curvilinear spars, ribs, and stringers. The baseline wing model is a fully-populated, cantilevered wing box structure of the Common Research Model (CRM). Metrics of interest include the wing weight, the onset of dynamic flutter, and the static aeroelastic stresses. Twelve parametric studies alter the number of internal structural members along with their location, orientation, and curvature. Additional evaluation metrics are considered to identify design trends that lead to lighter-weight, aeroelastically stable wing designs. The best designs of the individual studies are compared and discussed, with a focus on weight reduction and flutter resistance. The largest weight reductions were obtained by removing the inner spar, and performance was maintained by shifting stringers forward and/or using curvilinear ribs: 5.6% weight reduction, a 13.9% improvement in flutter speed, but a 3.0% increase in stress levels. Flutter resistance was also maintained using straight-rotated ribs although the design had a 4.2% lower flutter speed than the curved ribs of similar weight and stress levels were higher. For some configurations, the differences between curved and straight ribs were smaller, which provides motivation for future optimization-based studies to fully exploit the trade-offs.

  17. [Electrophysiological findings and ablation strategies in patients with atrial tachyarrhythmias after left atrial circumferential ablation in the treatment of atrial fibrillation].

    PubMed

    Chen, Ming-long; Yang, Bing; Xu, Dong-jie; Zou, Jian-gang; Shan, Qi-jun; Chen, Chun; Chen, Hong-wu; Li, Wen-qi; Cao, Ke-jiang

    2007-02-01

    To report the electrophysiological findings and the ablation strategies in patients with atrial tachyarrhythmias (ATAs) or atrial fibrillation (AF) recurrence after left atrial circumferential ablation (LACA) in the treatment of AF. 91 patients with AF had LACA procedure from April 2004 to May 2006, 19 of which accepted the second ablation procedure due to ATAs or AF recurrence. In all the 19 patients [17 male, 2 female, age 25 - 65 (53 +/- 12) years], 11 presented with paroxysmal AF before the first ablation procedure, 2 with persistent AF and 6 with permanent AF. Pulmonary vein potentials (PVP) were investigated in both sides in all the patients. Delayed PVP was identified inside the left circular line in 5 patients, in the right in 1 and both in 2 during sinus rhythm. "Gap" conduction was found and successfully closed guided by circular mapping catheter. In 3 cases, irregular left atrial tachycardia was caused by fibrillation rhythm inside the left ring via decremental "gap" conduction. Reisolation was done successfully again guided by 3-D mapping and made the left atrium in sinus rhythm but the fibrillation rhythm was still inside the left ring. Pulmonary vein tachycardia with 1:1 conduction to the left atrium presented in one case and reisolation stopped the tachycardia. No PVP was discovered in both sides in 4 patients but other tachycardias could be induced, including two right atrial scar related tachycardias, two supraventricular tachycardias mediated by concealed accessory pathway, one cavo-tricuspid isthmus dependent atrial flutter and one focal atrial tachycardia near the coronary sinus ostium. All the tachycardias in these 4 patients were successfully ablated with the help of routine and 3-D mapping techniques. In the rest 3, which were in AF rhythm, LACA was successfully done again. After a mean follow-up of 4 - 26 (11.5 +/- 8.5) months, 16 patients were symptom free without anti-arrhythmic drug therapy; 1 of them had frequent palpitation attack with Holter recording of atrial premature contractions; 2 of them with permanent AF became paroxysmal in one, and still in AF in the other. Reconduction between the left atrium and the pulmonary veins is the dominant factor for post-LACA ATAs and AF recurrence. Other forms of atrial tachycardias or supraventricular tachycardias may coexist with AF or sometimes trigger AF. LACA can not sufficiently modify AF substrate in some permanent AF patients.

  18. Uncertainty Quantification of the FUN3D-Predicted NASA CRM Flutter Boundary

    NASA Technical Reports Server (NTRS)

    Stanford, Bret K.; Massey, Steven J.

    2017-01-01

    A nonintrusive point collocation method is used to propagate parametric uncertainties of the flexible Common Research Model, a generic transport configuration, through the unsteady aeroelastic CFD solver FUN3D. A range of random input variables are considered, including atmospheric flow variables, structural variables, and inertial (lumped mass) variables. UQ results are explored for a range of output metrics (with a focus on dynamic flutter stability), for both subsonic and transonic Mach numbers, for two different CFD mesh refinements. A particular focus is placed on computing failure probabilities: the probability that the wing will flutter within the flight envelope.

  19. High intensity focused ultrasound ablation for atrial fibrillation: results from the National Spanish Registry.

    PubMed

    Reyes, Guillermo; Ruyra, Xavier; Valderrama, Francisco; Jimenez, Antonio; Duran, Dario; Perez, Enrique; Daroca, Tomas; Moya, Javier; Ramirez, Ulises; Aldamiz, Gonzalo

    2016-10-01

    A National Spanish Registry to compile all patients treated with high intensity focused ultrasound (HIFU) energy for atrial fibrillation (AF) was created to evaluate the safety and efficacy of AF surgical ablation. A national Spanish registry was created, and ten hospitals using HIFU to ablate AF joined it. A total of 412 patients undergoing cardiac surgery between 2006 and February 2013 were included. AF was divided between paroxysmal AF (33%) and persistent AF (67%) with a mean AF duration of 29.3±108.2 months. Mean left atrial diameter was 51.2±6.5 mm. Mean underlying heart disease were aortic valve disease (49.3%), ischemic disease (25.2%) and mitral disease (33.2%) Clinical follow-up of patients and a 6 months postoperative echocardiogram were performed in all patients. A pacemaker implantation was needed in 4.9% of patients with a perioperative stroke in 2.5%. Rhythm at discharge from hospital was sinus rhythm in 58%, AF in 35.9% and atrial flutter in 0.8% of patients. Sinus rhythm restoration at 6, 12, 24 and 36 months follow-up was achieved in 66.1%, 63.8%, 63.9% and 45.9% of patients respectively. Multivariate analysis showed paroxysmal AF and sinus rhythm restoration in the operating theatre as factors related to sinus rhythm long term restoration. The Spanish national registry showed an efficacy of AF ablation with the HIFU Epicor system of 66.1%, 63.8%, 63.9% and 45.9% at 6, 12, 24 and 36 months follow-up. There were no device-related complications.

  20. [Safety of new anti-arrhythmic drugs].

    PubMed

    Touboul, P

    2005-04-01

    The majority of new antiarrhythmic drugs are still undergoing clinical trials and are not yet available on the French market. The studies of efficacy are mainly targeted on the treatment of atrial fibrillation. Intravenous ibutilide prolongs the duration of the action potential by stimulating sodium exchange during phase 2 of the action potential. Used for terminating episodes of atrial flutter and fibrillation, ibutilide has been shown to have a low proarrhythmic effect. Dofetilide is a pure I(Kr) current antagonist and is given orally. The molecule prolongs the duration of the atrial and ventricular action potentials. The amplitude of this effect is inversely related to the heart rate. No effect has been observed on the mortality rate in the post-infarct period. Adjusting the dosage with respect to renal function has reduced the occurrence of torsades de pointe from 4.8 to 2.9%. Azimilide is an I(Kr) and I(Ks) current blocker and its efficacy decreases at rapid heart rates. After oral administration, azimilide does not appear to have a deleterious effect in patients with a history of myocardial infarction and left ventricular dysfunction. The risk of torsades de pointe is less than 1%. Cases of neutropaenia have been reported. Dronedarone is an amiodarone analogue without iodine. The molecule prolongs atrial and ventricular action potentials and its efficacy is maintained at high heart rates. This drug had deleterious effects when given to patients with coronary artery disease and left ventricular dysfunction. Gastrointestinal side effects may be observed at high dosage. The great advantages of dronedarone are the absence of thyroid complications and of pro-arrhythmic effects.

  1. Clinical implications of atrial isomerism.

    PubMed Central

    Chiu, I S; How, S W; Wang, J K; Wu, M H; Chu, S H; Lue, H C; Hung, C R

    1988-01-01

    Right atrial isomerism or left atrial isomerism is frequently diagnosed as situs ambiguous without further discrimination of the specific morbid anatomy. Thirty six cases of right atrial isomerism and seven cases of left atrial isomerism were collected from the records and pathological museum at the National Taiwan University Hospital. There was a necropsy report for 18 cases. In all patients one or more of the following conditions was met: (a) isomeric bronchial anatomy, (b) echocardiographic and angiocardiographic evidence of isomerism, and (c) surgical or necropsy evidence of abnormal atrial anatomy. An anomalous pulmonary venous connection was present in 55% of patients with right atrial isomerism; in left atrial isomerism one case (14%) had a partial anomalous pulmonary venous connection. Forty per cent of cases of anomalous pulmonary venous connection with right atrial isomerism had obstruction. Six (86%) of seven cases with left atrial isomerism had an ambiguous biventricular atrioventricular connection. In contrast, univentricular atrioventricular connection (26 of 36, 72%) was significantly more common in right atrial isomerism. A common atrioventricular valve was the most frequent mode of connection in both forms. Two discrete atrioventricular valves were significantly more common in left atrial isomerism. Atrioventricular valve regurgitation was detected in 14 cases. Double outlet right ventricle was the most common type of ventriculoarterial connection. The most commonly cited causes of death after either palliative or definitive operation were undetected anomalous pulmonary venous connection, pulmonary venous stricture, and uncorrected atrioventricular valve or aortic regurgitation complicated by abnormal coagulation. Although the prognosis is poor, successful operation depends on knowledge of the precise anatomical arrangement associated with atrial isomerism. Images Fig 1 Fig 2 Fig 3 PMID:3408620

  2. Wireless monitoring of reconstructed 12-lead ECG in atrial fibrillation patients enables differential diagnosis of recurrent arrhythmias.

    PubMed

    Vukajlovic, Dejan; Gussak, Ihor; George, Samuel; Simic, Goran; Bojovic, Bosko; Hadzievski, Ljupco; Stojanovic, Bojan; Angelkov, Lazar; Panescu, Dorin

    2011-01-01

    Differential diagnosis of symptomatic events in post-ablation atrial fibrillation (AF) patients (pts) is important; in particular, accurate, reliable detection of AF or atrial flutter (AFL) is essential. However, existing remote monitoring devices usually require attached leads and are not suitable for prolonged monitoring; moreover, most do not provide sufficient information to assess atrial activity, since they generally monitor only 1-3 ECG leads and rely on RR interval variability for AF diagnosis. A new hand-held, wireless, symptom-activated event monitor (CardioBip; CB) does not require attached leads and hence can be conveniently used for extended periods. Moreover, CB provides data that enables remote reconstruction of full 12-lead ECG data including atrial signal information. We hypothesized that these CB features would enable accurate remote differential diagnosis of symptomatic arrhythmias in post-ablation AF pts. 21 pts who underwent catheter ablation for AF were instructed to make a CB transmission (TX) whenever palpitations, lightheadedness, or similar symptoms occurred, and at multiple times daily when asymptomatic, during a 60 day post-ablation time period. CB transmissions (TXs) were analyzed blindly by 2 expert readers, with differences adjudicated by consensus. 7 pts had no symptomatic episodes during the monitoring period. 14 of 21 pts had symptomatic events and made a total of 1699 TX, 164 of which were during symptoms. TX quality was acceptable for rhythm diagnosis and atrial activity in 96%. 118 TX from 10 symptomatic pts showed AF (96 TX from 10 pts) or AFL (22 TX from 3 pts), and 46 TX from 9 pts showed frequent PACs or PVCs. No other arrhythmias were detected. Five pts made symptomatic TX during AF/AFL and also during PACs/PVCs. Use of CB during symptomatic episodes enabled detection and differential diagnosis of symptomatic arrhythmias. The ability of CB to provide accurate reconstruction of 12 L ECGs including atrial activity, combined with its ease of use, makes it suitable for long-term surveillance for recurrent AF in post-ablation patients.

  3. Multidisciplinary aeroelastic analysis of a generic hypersonic vehicle

    NASA Technical Reports Server (NTRS)

    Gupta, K. K.; Petersen, K. L.

    1993-01-01

    This paper presents details of a flutter and stability analysis of aerospace structures such as hypersonic vehicles. Both structural and aerodynamic domains are discretized by the common finite element technique. A vibration analysis is first performed by the STARS code employing a block Lanczos solution scheme. This is followed by the generation of a linear aerodynamic grid for subsequent linear flutter analysis within subsonic and supersonic regimes of the flight envelope; the doublet lattice and constant pressure techniques are employed to generate the unsteady aerodynamic forces. Flutter analysis is then performed for several representative flight points. The nonlinear flutter solution is effected by first implementing a CFD solution of the entire vehicle. Thus, a 3-D unstructured grid for the entire flow domain is generated by a moving front technique. A finite element Euler solution is then implemented employing a quasi-implicit as well as an explicit solution scheme. A novel multidisciplinary analysis is next effected that employs modal and aerodynamic data to yield aerodynamic damping characteristics. Such analyses are performed for a number of flight points to yield a large set of pertinent data that define flight flutter characteristics of the vehicle. This paper outlines the finite-element-based integrated analysis procedures in detail, which is followed by the results of numerical analyses of flight flutter simulation.

  4. Management of Arrhythmias in Heart Failure

    PubMed Central

    Masarone, Daniele; Limongelli, Giuseppe; Rubino, Marta; Valente, Fabio; Vastarella, Rossella; Ammendola, Ernesto; Gravino, Rita; Verrengia, Marina; Salerno, Gemma; Pacileo, Giuseppe

    2017-01-01

    Heart failure patients are predisposed to develop arrhythmias. Supraventricular arrhythmias can exacerbate the heart failure symptoms by decreasing the effective cardiac output and their control require pharmacological, electrical, or catheter-based intervention. In the setting of atrial flutter or atrial fibrillation, anticoagulation becomes paramount to prevent systemic or cerebral embolism. Patients with heart failure are also prone to develop ventricular arrhythmias that can present a challenge to the managing clinician. The management strategy depends on the type of arrhythmia, the underlying structural heart disease, the severity of heart failure, and the range from optimization of heart failure therapy to catheter ablation. Patients with heart failure, irrespective of ejection fraction are at high risk for developing sudden cardiac death, however risk stratification is a clinical challenge and requires a multiparametric evaluation for identification of patients who should undergo implantation of a cardioverter defibrillator. Finally, patients with heart failure can also develop symptomatic bradycardia, caused by sinus node dysfunction or atrio-ventricular block. The treatment of bradycardia in these patients with pacing is usually straightforward but needs some specific issue. PMID:29367535

  5. Trial watch

    PubMed Central

    Menger, Laurie; Vacchelli, Erika; Kepp, Oliver; Eggermont, Alexander; Tartour, Eric; Zitvogel, Laurence; Kroemer, Guido; Galluzzi, Lorenzo

    2013-01-01

    Cardiac glycosides (CGs) are natural compounds sharing the ability to operate as potent inhibitors of the plasma membrane Na+/K+-ATPase, hence promoting—via an indirect mechanism—the intracellular accumulation of Ca2+ ions. In cardiomyocytes, increased intracellular Ca2+ concentrations exert prominent positive inotropic effects, that is, they increase myocardial contractility. Owing to this feature, two CGs, namely digoxin and digitoxin, have extensively been used in the past for the treatment of several cardiac conditions, including distinct types of arrhythmia as well as contractility disorders. Nowadays, digoxin is approved by the FDA and indicated for the treatment of congestive heart failure, atrial fibrillation and atrial flutter with rapid ventricular response, whereas the use of digitoxin has been discontinued in several Western countries. Recently, CGs have been suggested to exert potent antineoplastic effects, notably as they appear to increase the immunogenicity of dying cancer cells. In this Trial Watch, we summarize the mechanisms that underpin the unsuspected anticancer potential of CGs and discuss the progress of clinical studies that have evaluated/are evaluating the safety and efficacy of CGs for oncological indications. PMID:23525565

  6. Left atrial function in heart failure with impaired and preserved ejection fraction.

    PubMed

    Fang, Fang; Lee, Alex Pui-Wai; Yu, Cheuk-Man

    2014-09-01

    Left atrial structural and functional changes in heart failure are relatively ignored parts of cardiac assessment. This review illustrates the pathophysiological and functional changes in left atrium in heart failure as well as their prognostic value. Heart failure can be divided into those with systolic dysfunction and heart failure with preserved ejection fraction (HFPEF). Left atrial enlargement and dysfunction commonly occur in systolic heart failure, in particular, in idiopathic dilated cardiomyopathy. Atrial enlargement and dysfunction also carry important prognostic value in systolic heart failure, independently of known parameters such as left ventricular ejection fraction. In HFPEF, there is evidence of left atrial enlargement, impaired atrial compliance, and reduction of atrial pump function. This occurs not only at rest but also during exercise, indicating significant impairment of atrial contractile reserve. Furthermore, atrial dyssynchrony is common in HFPEF. These factors further contribute to the development of new onset or progression of atrial arrhythmias, in particular, atrial fibrillation. Left atrial function is an integral part of cardiac function and its structural and functional changes in heart failure are common. As changes of left atrial structure and function have different clinical implications in systolic heart failure and HFPEF, routine assessment is warranted.

  7. Design and rationale for the WARFA trial: a randomized controlled cross-over trial testing the therapeutic equivalence of branded and generic warfarin in atrial fibrillation patients in Brazil.

    PubMed

    Freitas, Carolina Gomes; Walsh, Michael; Atallah, Álvaro Nagib

    2017-06-07

    Warfarin is a commonly used anticoagulant. Whether a given dose of the different formulations of Brazilian warfarin will result in the same effect on the international normalized ratio (INR) is uncertain. The aim of the WARFA trial is to determine whether the branded and two generic warfarins available in Brazil differ in their effect on the INR. WARFA is a cross-over RCT comparing three warfarins. The formulations tested are the branded Marevan® (Uniao Quimica/Farmoquimica) and two generic warfarin (manufactured respectively by Uniao Quimica Farmaceutica Nacional and Laboratorio Teuto Brasileiro). All of them were manufactured in Brazil, are available in all settings of the Brazilian healthcare system and were purchased from retail drugstores. Eligible participants had atrial fibrillation or flutter, had been using warfarin for at least 2 months with a therapeutic range of 2.0-3.0 and had low variability in INR results during the 1st period of the trial. Our primary outcome, for which we have an equality hypothesis, is the difference between warfarins in the mean absolute difference between two INR results, obtained after three and 4 weeks with each drug. Our secondary outcomes, that will be tested for inequality (except for the mean INR, which will be tested for equality), include the difference in the warfarin dose, and time in therapeutic range. Clinical events and adherence were also recorded and will be reported. To our knowledge, WARFA will be the first comparison of the more readily applicable INR results between branded and generic warfarins in Brazil. WARFA is important because warfarins are commonly switched between in the course of a chronic treatment in Brazil. Final results of WARFA are expected in May 2017. ClinicalTrials.gov NCT02017197 . Registered 11 December 2013.

  8. Ischemic stroke due to embolic heart diseases and associated factors in Benin hospital setting.

    PubMed

    Gnonlonfoun, Dieudonné; Adjien, Constant; Gnimavo, Ronald; Goudjinou, Gérard; Hotcho, Corine; Nyangui Mapaga, Jennifer; Sowanou, Arlos; Gnigone, Pupchen; Domingo, Rodrigue; Houinato, Dismand

    2018-04-15

    Poor access to cardiovascular checkups is a major cause of ignorance of embolic heart diseases as the etiology for ischemic stroke. Study ischemic strokes due to embolic heart diseases and their associated factors. It was a cross-sectional, prospective, descriptive and analytical study conducted from November 1, 2014 to August 31, 2015 on 104 patients with ischemic stroke confirmed through brain imaging. Embolic heart diseases included arrhythmia due to atrial fibrillation (AF), atrial flutter, myocardial infarction (MI), heart valve diseases and atrial septal aneurysm (ASA). The dependent variable was embolic heart disease while independent variables encompassed socio-demographic factors, patients' history, and lifestyle. Data analysis was carried out through SAS 9.3. The rate of embolic heart diseases (EHD) as etiology for ischemic stroke was 26% (28/104). AF accounted for 69% of embolic heart diseases and 22.8% of etiologies for ischemic stroke. Ischemic strokes prevalence was 3.5%, 2.5% and 1.2% respectively for heart valve diseases, MI and ASA. The associated factor was age (p=0.000). The diagnosis of a potential cardiac source of embolism is essential because of therapeutic and prognostic implications. Wherefore, there is need for cardiovascular examination particularly Holter ECG and cardiac ultrasound examination which are not always accessible to our populations. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Correlation Filtering of Modal Dynamics using the Laplace Wavelet

    NASA Technical Reports Server (NTRS)

    Freudinger, Lawrence C.; Lind, Rick; Brenner, Martin J.

    1997-01-01

    Wavelet analysis allows processing of transient response data commonly encountered in vibration health monitoring tasks such as aircraft flutter testing. The Laplace wavelet is formulated as an impulse response of a single mode system to be similar to data features commonly encountered in these health monitoring tasks. A correlation filtering approach is introduced using the Laplace wavelet to decompose a signal into impulse responses of single mode subsystems. Applications using responses from flutter testing of aeroelastic systems demonstrate modal parameters and stability estimates can be estimated by correlation filtering free decay data with a set of Laplace wavelets.

  10. Six-month follow-up of isthmus-dependent right atrial flutter ablation using a remote magnetic catheter navigation system: a case-control study.

    PubMed

    Huo, Yan; Hindricks, Gerhard; Piorkowski, Christopher; Bollmann, Andreas; Wetzel, Ulrike; Sommer, Phillip; Gaspar, Thomas; Kottkamp, Hans; Arya, Arash

    2010-06-01

    The objective of this study was to compare results between the magnetic navigation system (MNS) and conventional catheter ablation of cavo-tricuspid isthmus (CTI)-dependent right atrial flutter (AFL) in a case control study. A remote MNS has been used for ablation of various arrhythmias including CTI-dependent AFL but comparative results between MNS and conventional ablation are not available. Between May and September 2007, a total of 51 consecutive patients (45 men, mean age 65.4 +/- 9.4 years) had undergone catheter ablation for CTI-dependent AFL. The catheter ablation (70 degrees C, 70 W, 90 s) was performed with either an 8-mm-tip magnetic catheter using MNS (case group, n = 26, 23 men, mean age 64.6 +/- 9.6 y) or a conventional 8-mm catheter (case group, n = 25, 22 men, mean age 65.4 +/- 9.1 y). Acute procedural success was defined as complete bidirectional isthmus block and success at six months was defined as absence of AFL during the six months follow-up. With respect to baseline characteristics there were no differences between the two groups. The procedure time in MNS and conventional group was [median (range)] 53 (30-130) min and 45 (30-100) min, respectively (P = 0.12). Acute success was achieved by MNS and conventional ablation in 25/26 (96.2%) and 25/25 (100%) of patients, respectively (P = 0.53). During the six months of follow-up 4 patients, 2 in each group, experienced recurrence (P = 0.90). No major complication occurred during the procedure. Charring on the catheter tip occurred in 5 patients (19.2%) in MNS and none of the patients in the control group (P <0.05). This case-control study demonstrated the acute and mid-term efficacy and safety of catheter ablation by MNS for CTI-dependent AFL, similar to rates achieved by conventional radiofrequency catheter ablation.

  11. Incidence and prognostic significance of new onset atrial fibrillation/flutter in acute pericarditis.

    PubMed

    Imazio, Massimo; Lazaros, George; Picardi, Elisa; Vasileiou, Panagiotis; Orlando, Fabrizio; Carraro, Mara; Tsiachris, Dimitris; Vlachopoulos, Charalambos; Georgiopoulos, George; Tousoulis, Dimitrios; Belli, Riccardo; Gaita, Fiorenzo

    2015-09-01

    Data on the incidence of new onset atrial fibrillation and flutter (AF/f) in patients with acute pericarditis are limited. We sought to determine the incidence and prognostic significance of AF/f in this setting. Between January 2006 and June 2014, consecutive new cases of acute pericarditis were included in two urban referral centres for pericardial diseases. All new cases of AF/f defined as episodes lasting ≥30 s were recorded. Events considered during follow-up consisted of AF/f and pericarditis recurrence, cardiac tamponade, pericardial constriction and death. 822 consecutive new cases of acute pericarditis (mean age 53±15 years, 444 men) were analysed. AF/f was detected in 35 patients (4.3%, mean age 66.5±11.3 years, 18 men). Patients with AF/f were significantly older (p=0.017) and presented more frequently with pericardial effusion (p<0.001). Arrhythmias developed within 24 h of pericarditis onset in 91.4% of cases, lasted >24 h in 25.7% and spontaneously converted in 74.3% of patients. Underlying structural heart disease was present in 17% of AF/f cases. In a 30-month follow-up, patients with history of AF/f at the initial episode had a higher rate of arrhythmia occurrence (34.3% vs 0.9%, p<0.001), mostly (75%) within 3 months. No other differences were detected in additional clinical events including haemorrhagic complications in patients receiving oral anticoagulation. The occurrence of AF/f in acute pericarditis identifies a predisposed population to AF/f with a high recurrence risk (about 35%): in these patients, pericarditis may act as an arrhythmic trigger and oral anticoagulation should be seriously considered according to guidelines. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Patent Foramen Ovale Closure for Secondary Prevention of Cryptogenic Stroke: Updated Meta-Analysis of Randomized Clinical Trials.

    PubMed

    Vaduganathan, Muthiah; Qamar, Arman; Gupta, Ankur; Bajaj, Navkaranbir; Golwala, Harsh B; Pandey, Ambarish; Bhatt, Deepak L

    2018-05-01

    Patent foramen ovale closure represents a potential secondary prevention strategy for cryptogenic stroke, but available trials have varied by size, device studied, and follow-up. We conducted a systematic search of published randomized clinical trials evaluating patent foramen ovale closure versus medical therapy in patients with recent stroke or transient ischemic attack using PubMED, EMBASE, and Cochrane through September 2017. Weighting was by random effects models. Of 480 studies screened, we included 5 randomized clinical trials in the meta-analysis in which 3440 patients were randomized to patent foramen ovale closure (n = 1829) or medical therapy (n = 1611) and followed for an average of 2.0 to 5.9 years. Index stroke/transient ischemic attack occurred within 6 to 9 months of randomization. The primary end point was composite stroke/transient ischemic attack and death (in 3 trials) or stroke alone (in 2 trials). Patent foramen ovale closure reduced the primary end point (0.70 vs 1.48 events per 100 patient-years; risk ratio [RR], 0.52 [0.29-0.91]; I 2  = 55.0%) and stroke/transient ischemic attack (1.04 vs 2.00 events per 100 patient-years; RR, 0.55 [0.37-0.82]; I 2  = 42.2%) with modest heterogeneity compared with medical therapy. Procedural bleeding was not different between study arms (1.8% vs 1.8%; RR, 0.94 [0.49-1.83]; I 2  = 29.2%), but new-onset atrial fibrillation/flutter was increased with patent foramen ovale closure (6.6% vs 0.7%; RR, 4.69 [2.17-10.12]; I 2  = 29.3%). In patients with recent cryptogenic stroke, patent foramen ovale closure reduces recurrent stroke/transient ischemic attack compared with medical therapy, but is associated with a higher risk of new-onset atrial fibrillation/flutter. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Effect of Chronic Kidney Diseases on Mortality among Digoxin Users Treated for Non-Valvular Atrial Fibrillation: A Nationwide Register-Based Retrospective Cohort Study.

    PubMed

    Sessa, Maurizio; Mascolo, Annamaria; Andersen, Mikkel Porsborg; Rosano, Giuseppe; Rossi, Francesco; Capuano, Annalisa; Torp-Pedersen, Christian

    2016-01-01

    This study investigated the impact of chronic kidney disease on all-causes and cardiovascular mortality in patients with atrial fibrillation treated with digoxin. All patients with non-valvular atrial fibrillation and/or atrial flutter as hospitalization diagnosis from January 1, 1997 to December 31, 2012 were identified in Danish nationwide administrative registries. Cox proportional hazard model was used to compare the adjusted risk of all-causes and cardiovascular mortality among patients with and without chronic kidney disease and among patients with different chronic kidney disease stages within 180 days and 2 years from the first digoxin prescription. We identified 37,981 patients receiving digoxin; 1884 patients had the diagnosis of chronic kidney disease. Cox regression analysis showed no statistically significant differences in all-causes (Hazard Ratio, HR 0.89; 95% confident interval, CI 0.78-1.03) and cardiovascular mortality (HR 0.88; 95%CI 0.74-1.05) among patients with and without chronic kidney disease within 180 days of follow-up period. No statistically significant differences was found using a 2 years follow-up period neither for all causes mortality (HR 0.90; 95%CI 0.79-1.03), nor for cardiovascular mortality (HR 0.87; 95%CI 0.74-1.02). No statistically significant differences was found comparing patients with and without estimated Glomerular Filtration Rate <30ml/min/1.73m2 and patients with different stages of chronic kidney disease, for all-causes and cardiovascular mortality within 180 days and 2 years from the first digoxin prescription. This study suggest no direct effect of chronic kidney disease and chronic kidney disease stages on all-causes and cardiovascular mortality within both 180 days and 2 years from the first digoxin prescription in patients treatment-naïve with digoxin for non-valvular atrial fibrillation.

  14. Wellens' syndrome and other electrocardiographic changes in a patient with a left anterior descending artery subocclusion associated with a left main coronary artery subocclusion.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2011-09-01

    Changing axis deviation has been reported also during atrial fibrillation or atrial flutter. Changing axis deviation has been also reported during acute myocardial infarction associated with atrial fibrillation too or at the end of atrial fibrillation during acute myocardial infarction. Patients with unstable angina have a higher incidence of left main coronary artery (LMCA) and proximal left anterior descending (LAD) coronary artery disease compared to patients with stable angina pectoris. In 1982, Wellens and colleagues described two electrocardiographic patterns that were predictive of critical narrowing of the proximal LAD artery, and were subsequently termed Wellens' syndrome. The criteria were: a) prior history of chest pain, b) little or no cardiac enzyme elevation, c) no pathologic precordial ST segment elevation, d) no loss of precordial R waves, and e) biphasic T waves in leads V2 and V3, or asymmetric, often deeply inverted T waves in leads V2 and V3. The ECG changes are best recognized outside the episode of anginal pain. Lead aVR and lead v1 ST segment elevation, during chest pain, has been reported in patients with LMCA disease with ST segment depression in leads V3, V4 and V5 (with maximal depression in V4).We present a case of changing axis deviation in a 37-year-old Italian man with a LAD coronary artery subocclusion associated with a LMCA subocclusion. This case focuses attention on the importance of the recognition of the patterns suspected for LAD coronary artery disease or for LMCA disease. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  15. Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: new insight into the mechanism of atrioventricular valve closure.

    PubMed

    Schnittger, I; Appleton, C P; Hatle, L K; Popp, R L

    1988-01-01

    The purpose of this study was to prospectively determine the incidence of diastolic mitral and tricuspid regurgitation in atrioventricular (AV) block using Doppler echocardiography. The temporal relation between mitral and tricuspid diastolic insufficiency and the diastolic murmur recorded in patients with complete heart block was also investigated. Twenty-two consecutive patients with AV block (referred to the Echo-Doppler laboratory for routine clinical studies), aged 18 to 87 years, were enrolled in the study. Eleven patients had third degree AV block and a ventricular-inhibited (VVI) pacemaker, two patients had second degree AV block, seven patients had first degree AV block, one patient had blocked premature atrial complexes and one patient had atrial flutter with 4:1 AV block. Diastolic mitral regurgitation was detected in 20 patients, and diastolic tricuspid regurgitation in 21. A mid-diastolic murmur was detected in all patients except in the three youngest. The murmur occurred before diastolic regurgitation and coincided with peak forward flow through the AV valve after atrial contraction. M-mode mitral valve echocardiograms obtained in nine patients demonstrated near closure of some portions of the mitral valve after atrial contraction. Effective closure of the valve, however, did not occur unless ventricular systole supervened. In conclusion, diastolic mitral and tricuspid regurgitation are almost universally present in patients with AV block and are associated with a diastolic murmur. The murmur coincides with forward AV valve flow. Diastolic regurgitation is silent. Effective AV valve closure is not established until ventricular systole occurs, as demonstrated by M-mode echocardiographic recording of the mitral valve.

  16. Is there still a role for the classical Cox-Maze III?

    PubMed

    Yap, Cheng-Hon; Prior, David; Kenny, James; Zimmet, Adam; Chao, Victor; Mooney, Donald; Yii, Michael

    2006-05-01

    The incidence of surgery for atrial fibrillation (AF) is rising, paralleled by an increase in the types of lesion sets and energy sources used. These alternate energy sources have simplified the surgery at the expense of increased cost of consumables. The classical Cox-Maze III is the gold standard therapy with a proven efficacy in curing AF. Our complete experience with this procedure is presented. All 28 patients undergoing the classical Cox-Maze III procedure at our institution underwent preoperative assessment and were followed prospectively. Twenty-eight patients underwent the Cox-Maze III procedure between January 2001 and May 2003. Their mean age was 65 years (range, 44-80 years). Twenty-five patients had concomitant cardiac procedures. Mean duration of AF was 8.3 years. Permanent AF was present in 82%. Mean follow-up time was 15 +/- 8 months (range, 4-30 months). There were no perioperative or late deaths, or thromboembolic events. Sixty-one per cent had early (<3 months) atrial arrhythmia. Freedom from AF at most recent clinical follow up was 93%. Freedom from late atrial arrhythmia was 82%. Freedom from late AF or atrial flutter by pacemaker interrogation or Holter assessment was 77%. Anti-arrhythmic medication use was reduced. New York Heart Association class improved from an average of 2.8 preoperatively to 1.3 postoperatively. The result of the present study shows the safety and efficacy of the classical Cox-Maze III procedure. With the advantage of proven long-term efficacy, demonstrable safety and avoidance of costly technology, the Cox-Maze III should not be discounted as a treatment option in patients because of its perceived complexity.

  17. P-wave morphology and the risk of incident ischemic stroke in the Multi-Ethnic Study of Atherosclerosis.

    PubMed

    Kamel, Hooman; Soliman, Elsayed Z; Heckbert, Susan R; Kronmal, Richard A; Longstreth, W T; Nazarian, Saman; Okin, Peter M

    2014-09-01

    Emerging data suggest that left atrial disease may cause ischemic stroke in the absence of atrial fibrillation or flutter (AF). If true, this condition may provide a cause for many strokes currently classified as cryptogenic. Among 6741 participants in the Multi-Ethnic Study of Atherosclerosis who were free of clinically apparent cerebrovascular or cardiovascular disease (including AF) at baseline, we examined the association between markers of left atrial abnormality on a standard 12-lead ECG-specifically P-wave area, duration, and terminal force in lead V1-and the subsequent risk of ischemic stroke while accounting for incident AF. During a median follow-up of 8.5 years, 121 participants (1.8%) had a stroke and 541 participants (8.0%) were diagnosed with AF. In Cox proportional hazards models adjusting for potential baseline confounders, P-wave terminal force in lead V1 was more strongly associated with incident stroke (hazard ratio per 1 SD increase, 1.21; 95% confidence interval, 1.02-1.44) than with incident AF (hazard ratio per 1 SD, 1.11; 95% confidence interval, 1.03-1.21). The association between P-wave terminal force in lead V1 and stroke was robust in numerous sensitivity analyses accounting for AF, including analyses that excluded those with any incident AF or modeled any incident AF as having been present from baseline. We found an association between baseline P-wave morphology and incident stroke even after accounting for AF. This association may reflect an atrial cardiopathy that leads to stroke in the absence of AF. © 2014 American Heart Association, Inc.

  18. Comparison of treatment outcomes between convergent procedure and catheter ablation for paroxysmal atrial fibrillation evaluated with implantable loop recorder monitoring.

    PubMed

    Jan, Matevž; Žižek, David; Geršak, Živa Miriam; Geršak, Borut

    2018-05-03

    While catheter ablation (CA) is an established treatment for symptomatic paroxysmal atrial fibrillation (AF), convergent epicardial and endocardial ablation procedure (CVP) has been primarily used to treat persistent AF. The aim of this single-center, prospective, randomized study was to compare treatment efficacy of CA and CVP in paroxysmal AF patients by monitoring AF, atrial tachycardia (AT), and atrial flutter (AFL) recurrence with Implantable Loop Recorder (ILR). Fifty patients (74% male) with history of paroxysmal AF were randomized between CA and CVP. Outcomes were determined by ILRs; every episode of AF/AT/AFL lasting 6 minutes or more was defined as a recurrence. AF burden (AFB) and required AF reinterventions (cardioversions and repeat ablations) were quantified after a 3-month blanking period. Total procedural (266 ± 44 vs. 242 ± 39 minutes) and ablation duration (52 ± 10 vs. 48 ± 12 minutes) was similar in both groups. Recurrence of AF/AT/AFL was more likely in the CA group compared to the CVP group (OR 3.78 (95% CI (1.17, 12.19), P  =  0.048)). During the follow-up period (mean 30.5 ± 6.9 months), higher AF burden and more reinterventions for recurrent AF were recorded in the CA group. There were more periprocedural complications in the CVP group (12.5%) compared to the CA group (0%). Treatment of paroxysmal AF with CVP showed less arrhythmia recurrence compared to CA. In addition, patients after CVP had fewer reinterventions and lower AF burden, but more periprocedural complications. © 2018 Wiley Periodicals, Inc.

  19. Simplified and refined structural modeling for economical flutter analysis and design

    NASA Technical Reports Server (NTRS)

    Ricketts, R. H.; Sobieszczanski, J.

    1977-01-01

    A coordinated use of two finite-element models of different levels of refinement is presented to reduce the computer cost of the repetitive flutter analysis commonly encountered in structural resizing to meet flutter requirements. One model, termed a refined model (RM), represents a high degree of detail needed for strength-sizing and flutter analysis of an airframe. The other model, called a simplified model (SM), has a relatively much smaller number of elements and degrees-of-freedom. A systematic method of deriving an SM from a given RM is described. The method consists of judgmental and numerical operations to make the stiffness and mass of the SM elements equivalent to the corresponding substructures of RM. The structural data are automatically transferred between the two models. The bulk of analysis is performed on the SM with periodical verifications carried out by analysis of the RM. In a numerical example of a supersonic cruise aircraft with an arrow wing, this approach permitted substantial savings in computer costs and acceleration of the job turn-around.

  20. Sedimentation and fluttering of a cylinder in a confined liquid

    NASA Astrophysics Data System (ADS)

    D'Angelo, Maria Veronica; Cachile, Mario; Hulin, Jean-Pierre; Auradou, Harold

    2017-10-01

    The sedimentation and fluttering (angular oscillation of the axis) of straight cylinders are studied in a viscous fluid at rest filling a vertical Hele-Shaw cell for different density contrasts ρs-ρf and fluid viscosities μf and for two cylinder densities ρs and diameters D . The influence of confinement in the cell is studied by comparing the present results to those of the literature for nonconfined fluids. While the confinement and the cylinder length L both influence strongly the mean sedimentation velocity Vs, the characteristics of the fluttering instability are much more similar in the confined and nonconfined cases. While the drag coefficient is nearly constant in a nonconfined fluid, it is larger here and depends both on L (due to flow blockage) and on the Reynolds number ReD=VsD ρf/μf ; the inertial and viscous drag components have equal magnitudes for ReD≃40 . For fluttering, instead, the key parameter is the Froude number Fr=Vs/Vg [Vg=√{(ρs-ρf) g L /ρf }] , and the fluttering oscillations vanish below Fr˜0.07 for all cylinders and fluids investigated. Above this threshold, the angular amplitude increases with Fr up to a plateau value, while that of the horizontal oscillations is, at first, very large and then decreases; both amplitudes are reduced when the viscous drag is dominant, but, if inertial drag is dominant, all data points follow a common trend. For all fluids and cylinders, too, the fluttering frequency varies as f =0.102 Vg/L . These features of fluttering are generally qualitatively similar to those reported in nonconfined fluids, but this instability is observable down to lower ReD values (≃24 instead of ˜200 ).

  1. [Clinical, electrocardiographic and echocardiographic aspects in elderly hypertensive patients in Senegal].

    PubMed

    Sarr, Simon Antoine; Babaka, Kana; Mboup, Mouhamadou Cherif; Fall, Pape Diadie; Dia, Khadidiatou; Bodian, Malick; Ndiaye, Mouhamadou Bamba; Kane, Adama; Diao, Maboury; Ba, Serigne Abdou

    2016-01-01

    Arterial hypertension (HTA) in the elderly is an independent risk factor for cardiovascular disease. Our study aims to describe the clinical, electrocardiographic and echocardiographic aspects of Arterial hypertension in elderly patients. We conducted a descriptive, cross-sectional study from January to September 2013. Hypertensive patients =60 years treated in Outpatient Cardiology Department at the Principal Hospital in Dakar were included in the study. Statistical data were analyzed using Epi Info 7 software and a p-value < 0.05 was taken as significant. A total of 208 patients were enrolled in the study. The average age was 69.9 years with a female predominance (sex ratio 0.85). Average blood pressure was 162/90 mm Hg. HTA was under control in 13% of cases. The ECG showed evidence of rhythm disturbance (17.78%), left atrial enlargement (45.19%), left ventricular hypertrophy (28.85%) and complete atrioventricular block in 2 cases. Holter ECG revealed non-sustained ventricular tachycardia (Lown class IVb) in 4 cases, paroxysmal atrial fibrillation in 6 cases and paroxysmal atrial flutter in 1 case. Echocardiography performed in 140 patients showed mainly concentric left ventricular hypertrophy in 25 patients, occuring more frequently in males (p=0,04) and dilated left atrium in 56,42% of cases, occuring more frequently in elderly patients (p= 0,01). Electrocardiographic and echocardiographic aspects in elderly hypertensive population are characterized by concentric left ventricular hypertrophy and by the frequency of arrhythmias sometimes revealed by long-term continuous external electrocardiographic recording.

  2. Increasing Prevalence of Atrial Fibrillation and Permanent Atrial Arrhythmias in Congenital Heart Disease.

    PubMed

    Labombarda, Fabien; Hamilton, Robert; Shohoudi, Azadeh; Aboulhosn, Jamil; Broberg, Craig S; Chaix, Marie A; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Macle, Laurent; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Khairy, Paul

    2017-08-15

    Atrial arrhythmias are the most common complication encountered in the growing and aging population with congenital heart disease. This study sought to assess the types and patterns of atrial arrhythmias, associated factors, and age-related trends. A multicenter cohort study enrolled 482 patients with congenital heart disease and atrial arrhythmias, age 32.0 ± 18.0 years, 45.2% female, from 12 North American centers. Qualifying arrhythmias were classified by a blinded adjudicating committee. The most common presenting arrhythmia was intra-atrial re-entrant tachycardia (IART) (61.6%), followed by atrial fibrillation (28.8%), and focal atrial tachycardia (9.5%). The proportion of arrhythmias due to IART increased with congenital heart disease complexity from 47.2% to 62.1% to 67.0% in patients with simple, moderate, and complex defects, respectively (p = 0.0013). Atrial fibrillation increased with age to surpass IART as the most common arrhythmia in those ≥50 years of age (51.2% vs. 44.2%; p < 0.0001). Older age (odds ratio [OR]: 1.024 per year; 95% confidence interval [CI]: 1.010 to 1.039; p = 0.001) and hypertension (OR: 2.00; 95% CI: 1.08 to 3.71; p = 0.029) were independently associated with atrial fibrillation. During a mean follow-up of 11.3 ± 9.4 years, the predominant arrhythmia pattern was paroxysmal in 62.3%, persistent in 28.2%, and permanent in 9.5%. Permanent atrial arrhythmias increased with age from 3.1% to 22.6% in patients <20 years to ≥50 years, respectively (p < 0.0001). IART is the most common presenting atrial arrhythmia in patients with congenital heart disease, with a predominantly paroxysmal pattern. However, atrial fibrillation increases in prevalence and atrial arrhythmias progressively become permanent as the population ages. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. a Modeling Method of Fluttering Leaves Based on Point Cloud

    NASA Astrophysics Data System (ADS)

    Tang, J.; Wang, Y.; Zhao, Y.; Hao, W.; Ning, X.; Lv, K.; Shi, Z.; Zhao, M.

    2017-09-01

    Leaves falling gently or fluttering are common phenomenon in nature scenes. The authenticity of leaves falling plays an important part in the dynamic modeling of natural scenes. The leaves falling model has a widely applications in the field of animation and virtual reality. We propose a novel modeling method of fluttering leaves based on point cloud in this paper. According to the shape, the weight of leaves and the wind speed, three basic trajectories of leaves falling are defined, which are the rotation falling, the roll falling and the screw roll falling. At the same time, a parallel algorithm based on OpenMP is implemented to satisfy the needs of real-time in practical applications. Experimental results demonstrate that the proposed method is amenable to the incorporation of a variety of desirable effects.

  4. Atrial Fibrillation: When the heart is not in rhythm | NIH MedlinePlus the Magazine

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: When the heart is not in rhythm Past ... show, Deal With It . Photo: TBS/Deal Understanding Atrial Fibrillation Atrial fibrillation (AFib) is the most common type ...

  5. Economical Unsteady High-Fidelity Aerodynamics for Structural Optimization with a Flutter Constraint

    NASA Technical Reports Server (NTRS)

    Bartels, Robert E.; Stanford, Bret K.

    2017-01-01

    Structural optimization with a flutter constraint for a vehicle designed to fly in the transonic regime is a particularly difficult task. In this speed range, the flutter boundary is very sensitive to aerodynamic nonlinearities, typically requiring high-fidelity Navier-Stokes simulations. However, the repeated application of unsteady computational fluid dynamics to guide an aeroelastic optimization process is very computationally expensive. This expense has motivated the development of methods that incorporate aspects of the aerodynamic nonlinearity, classical tools of flutter analysis, and more recent methods of optimization. While it is possible to use doublet lattice method aerodynamics, this paper focuses on the use of an unsteady high-fidelity aerodynamic reduced order model combined with successive transformations that allows for an economical way of utilizing high-fidelity aerodynamics in the optimization process. This approach is applied to the common research model wing structural design. As might be expected, the high-fidelity aerodynamics produces a heavier wing than that optimized with doublet lattice aerodynamics. It is found that the optimized lower skin of the wing using high-fidelity aerodynamics differs significantly from that using doublet lattice aerodynamics.

  6. Improved understanding of the pathophysiology of atrial fibrillation through the lens of discrete pathological pathways

    PubMed Central

    Balouch, Muhammad A.; Kolek, Matthew J.; Darbar, Dawood

    2014-01-01

    Atrial fibrillation (AF) is a common disorder with a complex and incompletely understood pathophysiology. Genetic approaches to understanding the pathophysiology of AF have led to the identification of several biological pathways important in the pathogenesis of the arrhythmia. These include pathways important for cardiac development, generation and propagation of atrial electrical impulses, and atrial remodeling and fibrosis. While common and rare genetic variants in these pathways are associated with increased susceptibility to AF, they differ substantially among patients with lone versus typical AF. Furthermore, how these pathways converge to a final common clinical phenotype of AF is unclear and might also vary among different patient populations. Here, we review the contemporary knowledge of AF pathogenesis and discuss how derangement in cardiac development, ion channel dysfunction, and promotion of atrial fibrosis may contribute to this common and important clinical disorder. PMID:25054116

  7. A benefit-risk assessment of class III antiarrhythmic agents.

    PubMed

    Brendorp, Bente; Pedersen, Oledyg; Torp-Pedersen, Christian; Sahebzadah, Naji; Køber, Lars

    2002-01-01

    With beta-blockers as the exception, increasing doubt is emerging on the value of antiarrhythmic drug therapy following a series of trials that have either shown no mortality benefit or even an excess mortality. Vaughan Williams class I drugs are generally avoided in patients with structural heart disease, and class IV drugs are avoided in heart failure. Unfortunately, arrhythmias are a growing problem due to an increase in the incidence of atrial fibrillation and sudden death. The population is becoming older and more patients survive for a longer time period with congestive heart failure, which again increases the frequency of both supraventricular as well as ventricular arrhythmias. Class III antiarrhythmic drugs act by blocking repolarising currents and thereby prolong the effective refractory period of the myocardium. This is believed to facilitate termination of re-entry tachyarrhythmias. This class of drugs is developed for treatment of both supraventricular and ventricular arrhythmias. Amiodarone, sotalol, dofetilide, and ibutilide are examples of class III drugs that are currently available. Amiodarone and sotalol have other antiarrhythmic properties in addition to pure class III action, which differentiates them from the others. However, all have potential serious adverse events. Proarrhythmia, especially torsade de pointes, is a common problem making the benefit-risk ratio of these drugs a key question. Class III drugs have been evaluated in different settings: primary and secondary prevention of ventricular arrhythmias and in treatment of atrial fibrillation or flutter. Based on existing evidence there is no routine indication for antiarrhythmic drug therapy other than beta-blockers in patients at high risk of sudden death. Subgroup analyses of trials with amiodarone and dofetilide suggest that patients with atrial fibrillation may have a mortality reduction with these drugs. However, this needs to be tested in a prospective trial. Similarly, subgroups that will benefit from prophylactic treatment with class III antiarrhythmic drugs may be found based on QT-intervals or - in the future - from genetic testing. Class III drugs are effective in converting atrial fibrillation to sinus rhythm and for the maintenance of sinus rhythm after conversion. This is currently by far the most important indication for this class of drugs. As defined by recent guidelines, amiodarone and dofetilide have their place as second-line therapy except for patients with heart failure where they are first line therapy being the only drugs where the safety has been documented for this group of high risk patients.

  8. Holter-electrocardiogram-monitoring in patients with acute ischaemic stroke (Find-AFRANDOMISED): an open-label randomised controlled trial.

    PubMed

    Wachter, Rolf; Gröschel, Klaus; Gelbrich, Götz; Hamann, Gerhard F; Kermer, Pawel; Liman, Jan; Seegers, Joachim; Wasser, Katrin; Schulte, Anna; Jürries, Falko; Messerschmid, Anna; Behnke, Nico; Gröschel, Sonja; Uphaus, Timo; Grings, Anne; Ibis, Tugba; Klimpe, Sven; Wagner-Heck, Michaela; Arnold, Magdalena; Protsenko, Evgeny; Heuschmann, Peter U; Conen, David; Weber-Krüger, Mark

    2017-04-01

    Atrial fibrillation is a major risk factor for recurrent ischaemic stroke, but often remains undiagnosed in patients who have had an acute ischaemic stroke. Enhanced and prolonged Holter-electrocardiogram-monitoring might increase detection of atrial fibrillation. We therefore investigated whether enhanced and prolonged rhythm monitoring was better for detection of atrial fibrillation than standard care procedures in patients with acute ischaemic stroke. Find-AF randomised is an open-label randomised study done at four centres in Germany. We recruited patients with acute ischaemic stroke (symptoms for 7 days or less) aged 60 years or older presenting with sinus rhythm and without history of atrial fibrillation. Patients were included irrespective of the suspected cause of stroke, unless they had a severe ipsilateral carotid or intracranial artery stenosis, which were the exclusion criteria. We used a computer-generated allocation sequence to randomly assign patients in a 1:1 ratio with permuted block sizes of 2, 4, 6, and 8, stratified by centre, to enhanced and prolonged monitoring (ie, 10-day Holter-electrocardiogram [ECG]-monitoring at baseline, and at 3 months and 6 months of follow-up) or standard care procedures (ie, at least 24 h of rhythm monitoring). Participants and study physicians were not masked to group assignment, but the expert committees that adjudicated endpoints were. The primary endpoint was the occurrence of atrial fibrillation or atrial flutter (30 sec or longer) within 6 months after randomisation and before stroke recurrence. Because Holter ECG is a widely used procedure and not known to harm patients, we chose not to assess safety in detail. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01855035. Between May 8, 2013, and Aug 31, 2014, we recruited 398 patients. 200 patients were randomly assigned to the enhanced and prolonged monitoring group and 198 to the standard care group. After 6 months, we detected atrial fibrillation in 14% of 200 patients in the enhanced and prolonged monitoring group (27 patients) versus 5% in the control group (nine of 198 patients, absolute difference 9·0%; 95% CI 3·4-14·5, p=0·002; number needed to screen 11). Enhanced and prolonged monitoring initiated early in patients with acute ischaemic stroke aged 60 years or older was better than standard care for the detection of atrial fibrillation. These findings support the consideration of all patients aged 60 years or older with stroke for prolonged monitoring if the detection of atrial fibrillation would result in a change in medical management (eg, initiation of anticoagulation). Boehringer Ingelheim. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Prediction of Flutter Boundary Using Flutter Margin for The Discrete-Time System

    NASA Astrophysics Data System (ADS)

    Dwi Saputra, Angga; Wibawa Purabaya, R.

    2018-04-01

    Flutter testing in a wind tunnel is generally conducted at subcritical speeds to avoid damages. Hence, The flutter speed has to be predicted from the behavior some of its stability criteria estimated against the dynamic pressure or flight speed. Therefore, it is quite important for a reliable flutter prediction method to estimates flutter boundary. This paper summarizes the flutter testing of a wing cantilever model in a wind tunnel. The model has two degree of freedom; they are bending and torsion modes. The flutter test was conducted in a subsonic wind tunnel. The dynamic data responses was measured by two accelerometers that were mounted on leading edge and center of wing tip. The measurement was repeated while the wind speed increased. The dynamic responses were used to determine the parameter flutter margin for the discrete-time system. The flutter boundary of the model was estimated using extrapolation of the parameter flutter margin against the dynamic pressure. The parameter flutter margin for the discrete-time system has a better performance for flutter prediction than the modal parameters. A model with two degree freedom and experiencing classical flutter, the parameter flutter margin for the discrete-time system gives a satisfying result in prediction of flutter boundary on subsonic wind tunnel test.

  10. The design, analysis, and testing of a low-budget wind-tunnel flutter model with active aerodynamic controls

    NASA Technical Reports Server (NTRS)

    Bolding, R. M.; Stearman, R. O.

    1976-01-01

    A low budget flutter model incorporating active aerodynamic controls for flutter suppression studies was designed as both an educational and research tool to study the interfering lifting surface flutter phenomenon in the form of a swept wing-tail configuration. A flutter suppression mechanism was demonstrated on a simple semirigid three-degree-of-freedom flutter model of this configuration employing an active stabilator control, and was then verified analytically using a doublet lattice lifting surface code and the model's measured mass, mode shapes, and frequencies in a flutter analysis. Preliminary studies were significantly encouraging to extend the analysis to the larger degree of freedom AFFDL wing-tail flutter model where additional analytical flutter suppression studies indicated significant gains in flutter margins could be achieved. The analytical and experimental design of a flutter suppression system for the AFFDL model is presented along with the results of a preliminary passive flutter test.

  11. Effects of novel oral anticoagulants on left atrial and left atrial appendage thrombi: an appraisal.

    PubMed

    Marsico, Fabio; Cecere, Milena; Parente, Antonio; Paolillo, Stefania; de Martino, Fabiana; Dellegrottaglie, Santo; Trimarco, Bruno; Perrone Filardi, Pasquale

    2017-02-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and predisposes to an increased risk of thromboembolic events. Patients affected by AF exhibit an increased risk of stroke compared with those in sinus rhythm, with the most common location of thrombi in the left atrial appendage. Until 2009, warfarin and other vitamin K antagonists were the only class of oral anticoagulants available. More recently, dabigatran, rivaroxaban, apixaban, and edoxaban have been approved by regulatory authorities for prevention of stroke in patients with non-valvular AF. Few data are available about the efficacy of novel oral anticoagulants for the treatment of left atrial and left atrial appendage thrombosis. Aim of this review is to summarize available evidence regarding the effectiveness of novel oral anticoagulants on left atrial appendage thrombosis.

  12. A new therapeutic strategy for electrical cardioversion of atrial fibrillation.

    PubMed

    de Luca, I; Sorino, M; Del Salvatore, B; de Luca, L

    2001-11-01

    The conventional approach to cardioversion of atrial fibrillation includes a period of anticoagulation with oral anticoagulant therapy (OAT) extending from 3 weeks precardioversion to 4 weeks postcardioversion. The protocol of rapid anticoagulation (such as that of the ACUTE study) consists of a precardioversion transesophageal echocardiography (TEE) followed by OAT for 4 weeks. In the last few years low-molecular-weight heparins have established themselves as a safe and efficacious alternative to traditional antithrombotic therapies. The aim of this study was to demonstrate that the exclusion of thrombi by precardioversion TEE together with the exclusion of atrial stunning by a second TEE performed after 1 week, to date not suggested in the literature, could reduce to 7 days the period of pericardioversion anticoagulation. This therapy would be carried out using low-molecular-weight heparins with no need for biological monitoring and with the possibility of self-administration. We have studied 57 consecutive patients who had atrial fibrillation or flutter with a history of atrial fibrillation lasting > 48 hours. All patients received enoxaparin at a dosage of 100 IU antiXa/kg twice daily before undergoing multiplane TEE. Previous informed consent and ethical committee authorization had been obtained. Twenty-four hours following TEE, in the absence of thrombi and/or spontaneous moderate/severe echocontrast in the atrial chambers, the patients underwent electrical cardioversion and were discharged within 24 hours of sinus rhythm restoration. These patients were prescribed enoxaparin at the indicated dosage twice daily until TEE, performed in an outpatients setting 7 days following cardioversion. In the absence of thrombi and/or atrial and/or left atrial appendage stunning, OAT was terminated. Enoxaparin was associated with OAT for the following 3 weeks if any of the following signs of stunning were present: A wave inferior to the normal value for age at transmitral Doppler; a left atrial appendage emptying velocity < 40 cm/s; the appearance or increase in the severity of spontaneous echocontrast. For all patients, clinical and electrocardiographic follow-up was carried out at 1 month. In one patient TEE was not tolerated and one refused it. In 7 patients cardioversion was not performed: 4 because of the presence of thrombi, 1 because of moderate/severe spontaneous echocontrast and 2 owing to spontaneous cardioversion. Of the remaining 48 patients, cardioversion proved to be efficacious in 38, with sustained sinus rhythm at 1 week in 33 patients. One of these refused the second TEE and of the remaining 32 patients, 24 (75%) showed no signs of stunning at the second TEE and so anticoagulation was terminated. Thus, after 1 week, 75% (24/33) of patients in sinus rhythm could benefit from a shortened anticoagulation therapy which lasted for a mean of only 8.5 days. No patients showed signs of a thromboembolic accident at 1 and 2 months of follow-up. Most patients undergoing electrical cardioversion for atrial fibrillation could benefit from a shorter period of anticoagulation with low-molecular-weight heparins for 1 week if TEE precardioversion and 7 days postcardioversion excludes thrombi and atrial stunning. The management of patients with atrial fibrillation would be greatly simplified.

  13. AGARD standard aeroelastic configurations for dynamic response. 1: Wing 445.6

    NASA Technical Reports Server (NTRS)

    Yates, E. Carson, Jr.

    1988-01-01

    This report contains experimental flutter data for the AGARD 3-D swept tapered standard configuration Wing 445.6, along with related descriptive data of the model properties required for comparative flutter calculations. As part of a cooperative AGARD-SMP program, guided by the Sub-Committee on Aeroelasticity, this standard configuration may serve as a common basis for comparison of calculated and measured aeroelastic behavior. These comparisons will promote a better understanding of the assumptions, approximations and limitations underlying the various aerodynamic methods applied, thus pointing the way to further improvements.

  14. Increased susceptibility to atrial fibrillation secondary to atrial fibrosis in transgenic goats expressing transforming growth factor - B1

    USDA-ARS?s Scientific Manuscript database

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in people with significant morbidity and mortality. There is a strong association between atrial fibrosis and AF. Transforming growth factor B1 (TGF-B1) is an essential mediator of atrial fibrosis in animal models and human pat...

  15. Thinking outside the Box: Rotor Modulation in the Treatment of Atrial Fibrillation.

    PubMed

    Sehra, Ruchir; Narayan, Sanjiv M; Hummel, John

    2013-01-01

    Ablation for atrial fibrillation (AF) is an important and exciting therapy whose results remain suboptimal. Although most clinical trials show that ablation eliminates AF more effectively than medications, it is disappointing that the continued single procedural success remains ≈50% despite the substantial advances that have taken place in imaging, catheter positioning and energy delivery. Focal impulse and rotor modulation (FIRM), on the other hand, offers the opportunity to precisely define and then ablate patient-specific sustaining mechanisms for AF, rather than trying to eliminate all possible AF triggers. For over a decade, electrophysiologists have described cases in which AF terminates after only limited ablation - usually that cannot be explained by 'random' meandering wavelets. Indeed, recent studies from several laboratories show that all forms of clinical AF are typically 'driven' by stable electrical rotors and focal sources, not by multiple meandering waves. FIRM mapping enables an operator to place a catheter at typically 1-3 predicted sites in the atria, and with <5-10 minutes of RF ablation, terminate AF and potentially render it non-inducible. Several independent laboratories have now shown that such FIRM ablation alone can terminate or substantially slow AF in >80% of patients with persistent and paroxysmal AF and increase the single procedure rate of AF elimination from 50% with PV isolation alone to >80%. Ongoing studies hint that FIRM only ablation, enabling ablation times in the range observed for typical atrial flutter, may also achieve these high success rates without subsequent trigger ablation. This review summarizes the current state-of-the-art on FIRM mapping and ablation.

  16. [Late arrhythmias in the operated interatrial communication. Analysis of sinus node function and the conduction pathways by His bundle electrocardiography].

    PubMed

    Ramírez, A; Gil, M; Martínez Ríos, M A; Cárdenas, M; Pliego, J; Zamora, C; Mata, L A

    1982-01-01

    Four hundred patients with atrial septal defect treated surgically were reviewed. Thirty five (8.7%) developed arrhytmias post-surgery which persisted for over a year. Sinus bradycardia was found in 10 patients, nodal rhythm in 21, and atrial fibrilation and flutter in 4 patients. Thirty five per cent of the patients with late arrhythmias developed related symptomatology. In 14 patients the function of the sinus node was studied with electrical stimulation of the atrium and with His registry. The interatrial conduction time, AV node and His Purkinje were analized employing various stimulation frequencies. All the cases studied had normal intra-atrial conduction; the response of the atrio-ventricular node to increasing frequencies was normal, an the intraventricular conduction remained constant. In 8 patients (52%), alterations of the sinus node were found; these consisted of prolonged post-stimulation pauses, Wenckebach's type sinoatrial block and suppression of sinus automatism employing vagal procedures or through electrical stimulation. A patient with severe bradycardia detected by dynamic electrocardiography had to be treated with a permanent pacemaker. We confirm that these arrhytmias are not produced by lesions of the internodal tracts, and that an alteration of the sinus node is frequent without a concomitant lesion of the intraventricular pathway. The lesion to the nutrient artery could be due to trauma and/or surgically induced. The response to anticholinergic drugs was good. Prolonged observation of these patients could increase the morbility of these arrythmias and raise doubts of the surgical indications in cases with moderate hemodynamic repercussion.

  17. Sex Differences in the Relationship Between Amiodarone Use and the Need for Permanent Pacing in Patients With Atrial Fibrillation

    PubMed Central

    Essebag, Vidal; Reynolds, Matthew R.; Hadjis, Tom; Lemery, Robert; Olshansky, Brian; Buxton, Alfred E.; Josephson, Mark E.; Zimetbaum, Peter

    2008-01-01

    Background Amiodarone use was associated with an increased need for pacemaker insertion in a retrospective study of patients with atrial fibrillation (AF) and prior myocardial infarction. The aims of this study were to determine prospectively whether amiodarone increases the need for pacemakers in a general population of patients with AF and whether this effect is modified by sex. Methods The study included 1005 patients with new-onset AF who were enrolled in the Fibrillation Registry Assessing Costs, Therapies, Adverse events, and Lifestyle (FRACTAL). Multivariable Cox regression models, including time-dependent covariates accounting for medication exposure, were used to evaluate the risk of pacemaker insertion associated with amiodarone use. Results Amiodarone use was associated with an increased risk of pacemaker insertion (hazard ratio [HR], 2.01; 95% confidence interval [CI], 1.08–3.76) after adjustment for age, sex, atrial flutter, coronary artery disease, heart failure, and hypertension. The effect of amiodarone use was modified by sex, with a significant risk in women but not in men (HR, 4.69; 95% CI, 1.99–11.05 vs HR, 1.05; 95% CI, 0.42–2.58 [P = .02]). This interaction remained significant after adjustment for weight, body mass index, weight-adjusted amiodarone dose, and use of other antiarrhythmic or rate control drugs. Conclusion The risk of bradyarrhythmia requiring pacemaker insertion associated with amiodarone use for AF is significantly greater in women than in men, independent of weight or body mass index. PMID:17698688

  18. Design and experimental validation of a flutter suppression controller for the active flexible wing

    NASA Technical Reports Server (NTRS)

    Waszak, Martin R.; Srinathkumar, S.

    1992-01-01

    The synthesis and experimental validation of an active flutter suppression controller for the Active Flexible Wing wind tunnel model is presented. The design is accomplished with traditional root locus and Nyquist methods using interactive computer graphics tools and extensive simulation based analysis. The design approach uses a fundamental understanding of the flutter mechanism to formulate a simple controller structure to meet stringent design specifications. Experimentally, the flutter suppression controller succeeded in simultaneous suppression of two flutter modes, significantly increasing the flutter dynamic pressure despite modeling errors in predicted flutter dynamic pressure and flutter frequency. The flutter suppression controller was also successfully operated in combination with another controller to perform flutter suppression during rapid rolling maneuvers.

  19. Stall Flutter Control of a Smart Blade Section Undergoing Asymmetric Limit Oscillations

    DOE PAGES

    Li, Nailu; Balas, Mark J.; Nikoueeyan, Pourya; ...

    2016-01-01

    Stall flutter is an aeroelastic phenomenon resulting in unwanted oscillatory loads on the blade, such as wind turbine blade, helicopter rotor blade, and other flexible wing blades. While the stall flutter and related aeroelastic control have been studied theoretically and experimentally, microtab control of asymmetric limit cycle oscillations (LCOs) in stall flutter cases has not been generally investigated. This paper presents an aeroservoelastic model to study the microtab control of the blade section undergoing moderate stall flutter and deep stall flutter separately. The effects of different dynamic stall conditions and the consequent asymmetric LCOs for both stall cases are simulatedmore » and analyzed. Then, for the design of the stall flutter controller, the potential sensor signal for the stall flutter, the microtab control capability of the stall flutter, and the control algorithm for the stall flutter are studied. Lastly, the improvement and the superiority of the proposed adaptive stall flutter controller are shown by comparison with a simple stall flutter controller.« less

  20. Propfan test assessment testbed aircraft flutter model test report

    NASA Technical Reports Server (NTRS)

    Jenness, C. M. J.

    1987-01-01

    The PropFan Test Assessment (PTA) program includes flight tests of a propfan power plant mounted on the left wind of a modified Gulfstream II testbed aircraft. A static balance boom is mounted on the right wing tip for lateral balance. Flutter analyses indicate that these installations reduce the wing flutter stabilizing speed and that torsional stiffening and the installation of a flutter stabilizing tip boom are required on the left wing for adequate flutter safety margins. Wind tunnel tests of a 1/9th scale high speed flutter model of the testbed aircraft were conducted. The test program included the design, fabrication, and testing of the flutter model and the correlation of the flutter test data with analysis results. Excellent correlations with the test data were achieved in posttest flutter analysis using actual model properties. It was concluded that the flutter analysis method used was capable of accurate flutter predictions for both the (symmetric) twin propfan configuration and the (unsymmetric) single propfan configuration. The flutter analysis also revealed that the differences between the tested model configurations and the current aircraft design caused the (scaled) model flutter speed to be significantly higher than that of the aircraft, at least for the single propfan configuration without a flutter boom. Verification of the aircraft final design should, therefore, be based on flutter predictions made with the test validated analysis methods.

  1. Modal parameter estimation and monitoring for on-line flight flutter analysis

    NASA Astrophysics Data System (ADS)

    Verboven, P.; Cauberghe, B.; Guillaume, P.; Vanlanduit, S.; Parloo, E.

    2004-05-01

    The clearance of the flight envelope of a new airplane by means of flight flutter testing is time consuming and expensive. Most common approach is to track the modal damping ratios during a number of flight conditions, and hence the accuracy of the damping estimates plays a crucial role. However, aircraft manufacturers desire to decrease the flight flutter testing time for practical, safety and economical reasons by evolving from discrete flight test points to a more continuous flight test pattern. Therefore, this paper presents an approach that provides modal parameter estimation and monitoring for an aircraft with a slowly time-varying structural behaviour that will be observed during a faster and more continuous exploration of the flight envelope. The proposed identification approach estimates the modal parameters directly from input/output Fourier data. This avoids the need for an averaging-based pre-processing of the data, which becomes inapplicable in the case that only short data records are measured. Instead of using a Hanning window to reduce effects of leakage, these transient effects are modelled simultaneously with the dynamical behaviour of the airplane. The method is validated for the monitoring of the system poles during flight flutter testing.

  2. Concealed Accessory Pathways with a Single Ventricular and Two Discrete Atrial Insertion Sites.

    PubMed

    Kipp, Ryan T; Abu Sham'a, Raed; Hiroyuki, Ito; Han, Frederick T; Refaat, Marwan; Hsu, Jonathan C; Field, Michael E; Kopp, Douglas E; Marcus, Gregory M; Scheinman, Melvin M; Hoffmayer, Kurt S

    2017-03-01

    Atrioventricular reciprocating tachycardia (AVRT) utilizing a concealed accessory pathway is common. It is well appreciated that some patients may have multiple accessory pathways with separate atrial and ventricular insertion sites. We present three cases of AVRT utilizing concealed pathways with evidence that each utilizing a single ventricular insertion and two discrete atrial insertion sites. In case one, two discrete atrial insertion sites were mapped in two separate procedures, and only during the second ablation was the Kent potential identified. Ablation of the Kent potential at this site remote from the two atrial insertion sites resulted in the termination of the retrograde conduction in both pathways. Case two presented with supraventricular tachycardia (SVT) with alternating eccentric atrial activation patterns without alteration in the tachycardia cycle length. The two distinct atrial insertion sites during orthodromic AVRT and ventricular pacing were targeted and each of the two atrial insertion sites were successfully mapped and ablated. In case three, retrograde decremental conduction utilizing both atrial insertion sites was identified prior to ablation. After mapping and ablation of the first discrete atrial insertion site, tachycardia persisted utilizing the second atrial insertion site. Only after ablation of the second atrial insertion site was SVT noninducible, and VA conduction was no longer present. Concealed retrograde accessory pathways with discrete atrial insertion sites may have a common ventricular insertion site. Identification and ablation of the ventricular insertion site or the separate discrete atrial insertion sites result in successful treatment. © 2017 Wiley Periodicals, Inc.

  3. The feasibility of a Box isolation strategy for non-paroxysmal atrial fibrillation in elderly patients.

    PubMed

    Higuchi, Satoshi; Sohara, Hiroshi; Nakamura, Yoshinori; Ihara, Minoru; Yamaguchi, Yoshio; Shoda, Morio; Hagiwara, Nobuhisa; Satake, Shutaro

    2016-06-01

    Catheter ablation of non-paroxysmal atrial fibrillation (non-PAF) is a therapeutic challenge especially in elderly patients. This study describes the feasibility of a posterior left atrium isolation as a substrate modification in addition to pulmonary vein isolation, the so-called Box isolation, for elderly patients with non-PAF. Two hundred twenty-nine consecutive patients who underwent Box isolations for drug-refractory non-PAF were divided into two groups according to their age; younger group comprising 175 patients aged <75 years and elderly group comprising 54 patients aged ≥75 years. During 23.7±12.0 months of follow-up, the arrhythmia-free rates after one procedure were 53.1% in younger group versus 48.1% in elderly group (p=0.50). Following the second procedure, all patients had electrical conduction recoveries along the initial Box lesion. However, a complete Box re-isolation was highly established in both age groups (87.1% vs. 92.9%, respectively; p=1.00). Recurrence of macro-reentrant atrial tachycardia was mainly associated with the gaps through the initial Box lesion in both age groups (25.8% vs. 21.4%, p=1.00), but typical cavo-tricuspid isthmus (CTI) dependent atrial flutter was significantly observed in the elderly patients' group only (all events were observed within 6 months after the initial procedure; 3.2% vs. 28.6%, p=0.009). After two procedures, the arrhythmia-free rates increased to 73.1% in younger group versus 66.7% in elderly group (p=0.38). The occurrence rate of procedural-related complications did not differ between the two age groups, and there were no life-threatening complications even in elderly patients. Box isolation of non-PAF is effective and safe even in elderly patients. A prophylactic CTI ablation combined with Box isolation might be feasible to improve the long-term outcome.

  4. Stroke prediction with CHA2DS2-VASc score in patients with mesenteric ischemia without atrial fibrillation-insights from a nationwide cohort.

    PubMed

    Hu, Wei-Syun; Lin, Cheng-Li

    2017-11-01

    The current study sought to evaluate the accuracy of CHA 2 DS 2 -VASc score for ischemic stroke prediction in patients with mesenteric ischemia without atrial fibrillation (AF). The study participants included patients aged ≥18years with a new diagnosis of mesenteric ischemia during hospitalization between January 1, 2000 and December 31, 2011. Individuals with atrial fibrillation (AF) or atrial flutter during the study period were excluded. The study participants were followed up until the ischemic stroke appeared or they were censored due to withdrawal from this program, mortality, or the end of the study period, whichever came first. Cox proportional hazards regression models were applied for ischemic stroke risk stratification in the study participants by CHA 2 DS 2 -VASc score. The c-statistic based on the receiver operating characteristic (ROC) analysis was applied to investigate the accuracy of CHA 2 DS 2 -VASc score for ischemic stroke risk discrimination. A total of 24039 study participants were enrolled. Ischemic stroke incidence increased from 1.54% in CHA 2 DS 2 -VASc score of 0 to 9.23% in CHA 2 DS 2 -VASc score of 6 or more. Moreover, the Kaplan-Meier curve with a log rank test demonstrated that patients with a higher CHA 2 DS 2 -VASc score were associated with an increased cumulative incidence rate of ischemic stroke during the follow-up period (p<0.001). The discriminatory performance of the CHA2DS2-VASc score resulted in C-statistics of 0.65(95% CI=0.63-0.66) for predicting ischemic stroke risk among patients with mesenteric ischemia without AF. A higher CHA 2 DS 2 -VASc score is demonstrated to be associated with an increased risk of ischemic stroke among patients with mesenteric ischemia without comorbid AF. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Clinical, Echocardiographic, and Electrocardiographic Predictors of Persistent Atrial Fibrillation after Dual-Chamber Pacemaker Implantation: An Integrated Scoring Model Approach.

    PubMed

    Cho, Min Soo; Kim, Jun; Kim, Ju Hyeon; Kim, Minsu; Lee, Ji Hyun; Hwang, You Mi; Jo, Uk; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho

    2016-01-01

    Persistent atrial fibrillation (PeAF) predictors after dual-chamber pacemaker (PM) implantation remain unclear. We sought to determine these predictors and establish an integrated scoring model. Data were retrospectively reviewed for 649 patients (63.8 ± 12.3 years, 48.6% male, mean CHA2DS2-VASC score 2.7 ± 2.0) undergoing dual-chamber PM implantation. PeAF was defined as documented AF on two consecutive electrocardiograms acquired ≥7 days apart. During a 7.1-year median follow-up (interquartile range 4.5-10.1 years), 67 (10.3%) patients had PeAF. Multivariable analysis showed the following independent predictors of future PeAF: ischemic stroke or transient ischemic accident history (hazard ratio [HR] 2.03, 95% confidence interval [CI] 1.03-3.50, p = 0.040), atrial fibrillation/flutter history (HR 1.80, 95% CI 1.01-3.20, p = 0.046), sinus node disease (HR 2.24, 95% CI 1.16-4.35, p = 0.016), left atrial enlargement (>45 mm, HR 2.14, 95% CI 1.26-3.63, p = 0.005), and time in automatic mode switching >1% at first follow-up interrogation (HR 2.58, 95% CI 1.51-4.42, p < 0.001). An integrated scoring model combining these predictors showed good discrimination performance at the seven-year follow-up. (C-statistic 0.716, 95% CI 0.629-0.802, p < 0.001). Significantly greater seven-year PeAF incidences were seen in patients with higher scores (2-5) than in those with lower scores (0-1) (22.8% ± 3.8% vs. 5.3% ± 1.7%, p < 0.001). In conclusion, an integrated scoring model combining clinical, echocardiographic, and electrocardiographic characteristics is useful for predicting future PeAF in patients with a dual-chamber PM.

  6. Clinical, Echocardiographic, and Electrocardiographic Predictors of Persistent Atrial Fibrillation after Dual-Chamber Pacemaker Implantation: An Integrated Scoring Model Approach

    PubMed Central

    Cho, Min Soo; Kim, Ju Hyeon; Kim, Minsu; Lee, Ji Hyun; Hwang, You Mi; Jo, Uk; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho

    2016-01-01

    Persistent atrial fibrillation (PeAF) predictors after dual-chamber pacemaker (PM) implantation remain unclear. We sought to determine these predictors and establish an integrated scoring model. Data were retrospectively reviewed for 649 patients (63.8 ± 12.3 years, 48.6% male, mean CHA2DS2–VASC score 2.7 ± 2.0) undergoing dual-chamber PM implantation. PeAF was defined as documented AF on two consecutive electrocardiograms acquired ≥7 days apart. During a 7.1-year median follow-up (interquartile range 4.5–10.1 years), 67 (10.3%) patients had PeAF. Multivariable analysis showed the following independent predictors of future PeAF: ischemic stroke or transient ischemic accident history (hazard ratio [HR] 2.03, 95% confidence interval [CI] 1.03–3.50, p = 0.040), atrial fibrillation/flutter history (HR 1.80, 95% CI 1.01–3.20, p = 0.046), sinus node disease (HR 2.24, 95% CI 1.16–4.35, p = 0.016), left atrial enlargement (>45 mm, HR 2.14, 95% CI 1.26–3.63, p = 0.005), and time in automatic mode switching >1% at first follow-up interrogation (HR 2.58, 95% CI 1.51–4.42, p < 0.001). An integrated scoring model combining these predictors showed good discrimination performance at the seven-year follow-up. (C-statistic 0.716, 95% CI 0.629–0.802, p < 0.001). Significantly greater seven-year PeAF incidences were seen in patients with higher scores (2–5) than in those with lower scores (0–1) (22.8% ± 3.8% vs. 5.3% ± 1.7%, p < 0.001). In conclusion, an integrated scoring model combining clinical, echocardiographic, and electrocardiographic characteristics is useful for predicting future PeAF in patients with a dual-chamber PM. PMID:27479069

  7. Randomized trial of atrial arrhythmia monitoring to guide anticoagulation in patients with implanted defibrillator and cardiac resynchronization devices.

    PubMed

    Martin, David T; Bersohn, Malcolm M; Waldo, Albert L; Wathen, Mark S; Choucair, Wassim K; Lip, Gregory Y H; Ip, John; Holcomb, Richard; Akar, Joseph G; Halperin, Jonathan L

    2015-07-07

    Atrial tachyarrhythmias (ATs) detected by implanted devices are often atrial fibrillation or flutter (AF) associated with stroke. We hypothesized that introduction and termination of anticoagulation based upon AT monitoring would reduce both stroke and bleeding. We randomized 2718 patients with dual-chamber and biventricular defibrillators to start and stop anticoagulation based on remote rhythm monitoring vs. usual office-based follow-up with anticoagulation determined by standard clinical criteria. The primary analysis compared the composite endpoint of stroke, systemic embolism, and major bleeding with the two strategies. The trial was stopped after 2 years median follow-up based on futility of finding a difference in primary endpoints between groups. A total of 945 patients (34.8%) developed AT, 264 meeting study anticoagulation criteria. Adjudicated atrial electrograms confirmed AF in 91%; median time to initiate anticoagulation was 3 vs. 54 days in the intervention and control groups, respectively (P < 0.001). Primary events (2.4 vs. 2.3 per 100 patient-years) did not differ between groups (HR 1.06; 95% CI 0.75-1.51; P = 0.732). Major bleeding occurred at 1.6 vs. 1.2 per 100 patient-years (HR 1.39; 95% CI 0.89-2.17; P = 0.145). In patients with AT, thromboembolism rates were 1.0 vs. 1.6 per 100 patient-years (relative risk -35.3%; 95% CI -70.8 to 35.3%; P = 0.251). Although AT burden was associated with thromboembolism, there was no temporal relationship between AT and stroke. In patients with implanted defibrillators, the strategy of early initiation and interruption of anticoagulation based on remotely detected AT did not prevent thromboembolism and bleeding. IMPACT ClinicalTrials.gov identifier: NCT00559988 ( http://clinicaltrials.gov/ct2/show/NCT00559988?term=NCT00559988&rank=1 ). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  8. Bayesian Analysis for Risk Assessment of Selected Medical Events in Support of the Integrated Medical Model Effort

    NASA Technical Reports Server (NTRS)

    Gilkey, Kelly M.; Myers, Jerry G.; McRae, Michael P.; Griffin, Elise A.; Kallrui, Aditya S.

    2012-01-01

    The Exploration Medical Capability project is creating a catalog of risk assessments using the Integrated Medical Model (IMM). The IMM is a software-based system intended to assist mission planners in preparing for spaceflight missions by helping them to make informed decisions about medical preparations and supplies needed for combating and treating various medical events using Probabilistic Risk Assessment. The objective is to use statistical analyses to inform the IMM decision tool with estimated probabilities of medical events occurring during an exploration mission. Because data regarding astronaut health are limited, Bayesian statistical analysis is used. Bayesian inference combines prior knowledge, such as data from the general U.S. population, the U.S. Submarine Force, or the analog astronaut population located at the NASA Johnson Space Center, with observed data for the medical condition of interest. The posterior results reflect the best evidence for specific medical events occurring in flight. Bayes theorem provides a formal mechanism for combining available observed data with data from similar studies to support the quantification process. The IMM team performed Bayesian updates on the following medical events: angina, appendicitis, atrial fibrillation, atrial flutter, dental abscess, dental caries, dental periodontal disease, gallstone disease, herpes zoster, renal stones, seizure, and stroke.

  9. Chocolate Intake and Risk of Clinically Apparent Atrial Fibrillation: the Danish Diet, Cancer, and Health Study

    PubMed Central

    Mostofsky, Elizabeth; Johansen, Martin Berg; Tjønneland, Anne; Chahal, Harpreet S.; Mittleman, Murray A.; Overvad, Kim

    2018-01-01

    Objective To evaluate the association between chocolate intake and incident clinically apparent atrial fibrillation or flutter (AF).. Methods The Danish Diet, Cancer and Health Study is a large population-based prospective cohort study. The present study is based on 55,502 participants (26,400 men and 29,102 women) aged 50–64 years who had provided information on chocolate intake at baseline. Incident cases of AF were ascertained by linkage with nationwide registries. Results During a median of 13.5 years, there were 3,346 cases of AF. Compared with chocolate intake less than once per month, the rate of AF was lower for people consuming 1–3 servings/month (Hazard Ratio [HR]= 0.90, 95% confidence interval [CI] 0.82–0.98), 1 serving/week (HR= 0.83, 95% CI 0.74–0.92), 2–6 servings/week (HR= 0.80, 95% CI 0.71–0.91) and 1 servings/day (HR= 0.84, 95 %CI 0.65–1.09; p-linear trend<0.0001), with similar results for men and women. Conclusions Accumulating evidence indicates that moderate chocolate intake may be inversely associated with AF risk, though residual confounding cannot be ruled out. PMID:28536115

  10. Atrial Natriuretic Peptide Frameshift Mutation in Familial Atrial Fibrillation

    PubMed Central

    Hodgson-Zingman, Denice M.; Karst, Margaret L.; Zingman, Leonid V.; Heublein, Denise M.; Darbar, Dawood; Herron, Kathleen J.; Ballew, Jeffrey D.; de Andrade, Mariza; Burnett, John C.; Olson, Timothy M.

    2008-01-01

    Summary Atrial fibrillation is a common arrhythmia that is hereditary in a small subgroup of patients. In a family with 11 clinically affected members, we mapped an atrial fibrillation locus to chromosome 1p36-p35 and identified a heterozygous frameshift mutation in the gene encoding atrial natriuretic peptide. Circulating chimeric atrial natriuretic peptide (ANP) was detected in high concentration in subjects with the mutation, and shortened atrial action potentials were seen in an isolated heart model, creating a possible substrate for atrial fibrillation. This report implicates perturbation of the atrial natriuretic peptide–cyclic guanosine monophosphate (cGMP) pathway in cardiac electrical instability. PMID:18614783

  11. Study of flutter related computational procedures for minimum weight structural sizing of advanced aircraft

    NASA Technical Reports Server (NTRS)

    Oconnell, R. F.; Hassig, H. J.; Radovcich, N. A.

    1976-01-01

    Results of a study of the development of flutter modules applicable to automated structural design of advanced aircraft configurations, such as a supersonic transport, are presented. Automated structural design is restricted to automated sizing of the elements of a given structural model. It includes a flutter optimization procedure; i.e., a procedure for arriving at a structure with minimum mass for satisfying flutter constraints. Methods of solving the flutter equation and computing the generalized aerodynamic force coefficients in the repetitive analysis environment of a flutter optimization procedure are studied, and recommended approaches are presented. Five approaches to flutter optimization are explained in detail and compared. An approach to flutter optimization incorporating some of the methods discussed is presented. Problems related to flutter optimization in a realistic design environment are discussed and an integrated approach to the entire flutter task is presented. Recommendations for further investigations are made. Results of numerical evaluations, applying the five methods of flutter optimization to the same design task, are presented.

  12. A Dieulafoy's lesion in a duodenal diverticulum. An infrequent cause of UGIB.

    PubMed

    de Benito Sanz, Marina; Cimavilla Román, Marta; Torres Yuste, Raúl

    2018-04-01

    We present the case of an 82-year-old man with a history of heart failure, mitral regurgitation, type 2 DM, hypertension, dilated cardiomyopathy and a paroxysmal atrial flutter. The patient was under treatment with Sintrom. The patient presented to the emergency department due to melenic depositions of a one day evolution and dietary vomiting. There was no rectal bleeding and the patient was admitted three months previously due to self-limited melena with a normal gastroscopy. Anemia of 8 g and an overdose of Sintrom was diagnosed. A gastroscopy was performed and a large duodenal diverticulum with a fresh clot was found that was washed. A Dieulafoy lesion was subsequently found underneath with jet bleeding, which was sclerotic with adrenaline and a hemoclip. There was a favorable evolution after correcting the coagulopathy.

  13. Prevalence of atrial arrhythmias in arrhythmogenic right ventricular dysplasia/cardiomyopathy.

    PubMed

    Camm, Christian F; James, Cynthia A; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; te Riele, Anneline S J M; Judge, Daniel P; Tandri, Harikrishna; Calkins, Hugh

    2013-11-01

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is an inherited cardiomyopathy, characterized by right ventricular dysfunction and ventricular arrhythmias. Limited information is available concerning atrial arrhythmias in ARVD/C. The purpose of this study was to characterize spontaneous atrial arrhythmias in a large registry population of ARVD/C patients. Patients (n = 248) from the Johns Hopkins ARVD/C registry who met the diagnostic criteria and had undertaken genotype analysis were included. Medical records of each were reviewed to ascertain incidence and characteristics of atrial arrhythmia episodes. Detailed demographic, phenotypic, and structural information was obtained from registry data. Thirty-five patients with ARVD/C (14%) experienced one or more types of atrial arrhythmia during median follow-up of 5.78 (interquartile range 8.52) years. Atrial fibrillation was the most common atrial arrhythmia, occurring in 80% of ARVD/C patients with atrial arrhythmias. Patients developed atrial arrhythmias at a mean age of 43.0 ± 14.0 years. Atrial arrhythmia patients obtained a total of 22 inappropriate implantable cardioverter-defibrillator shocks during follow-up. Older age at last follow-up (P <.001) and male gender (P = .044) were associated with atrial arrhythmia development. Patients with atrial arrhythmias had a higher occurrence of death (P = .028), heart failure (P <.001), and left atrial enlargement on echocardiography (P = .004). Atrial arrhythmias are common in ARVD/C and present at a younger age than in the general population. They are associated with male gender, increasing age, and left atrial enlargement. Atrial arrhythmias are clinically important as they are associated with inappropriate implantable cardioverter-defibrillator shocks and increased risk of both death and heart failure. © 2013 Heart Rhythm Society. All rights reserved.

  14. Flutter suppression for the Active Flexible Wing - Control system design and experimental validation

    NASA Technical Reports Server (NTRS)

    Waszak, M. R.; Srinathkumar, S.

    1992-01-01

    The synthesis and experimental validation of a control law for an active flutter suppression system for the Active Flexible Wing wind-tunnel model is presented. The design was accomplished with traditional root locus and Nyquist methods using interactive computer graphics tools and with extensive use of simulation-based analysis. The design approach relied on a fundamental understanding of the flutter mechanism to formulate understanding of the flutter mechanism to formulate a simple control law structure. Experimentally, the flutter suppression controller succeeded in simultaneous suppression of two flutter modes, significantly increasing the flutter dynamic pressure despite errors in the design model. The flutter suppression controller was also successfully operated in combination with a rolling maneuver controller to perform flutter suppression during rapid rolling maneuvers.

  15. Who Is at Risk for Atrial Fibrillation?

    MedlinePlus

    ... JavaScript on. Feature: Atrial Fibrillation Who Is at Risk for Atrial Fibrillation? Past Issues / Winter 2015 Table ... than 75. AFib is uncommon in children. Major Risk Factors AFib is more common in people who ...

  16. Arrhythmias in Adults with Congenital Heart Disease: What Are Risk Factors for Specific Arrhythmias?

    PubMed

    Loomba, Rohit S; Buelow, Matthew W; Aggarwal, Saurabh; Arora, Rohit R; Kovach, Joshua; Ginde, Salil

    2017-04-01

    An increasing number of patients with congenital heart disease are now surviving into adulthood. This has also led to the emergence of complications from the underlying congenital heart disease, related surgical interventions, and associated combordities. While the prevalence of particular arrhythmias with specific congenital heart disease has been previously described, a detailed analysis of all lesions and a large number of comorbidities has not been previously published. Admissions with congenital heart disease were identified in the National Inpatient Sample. Associated comorbidities were also identified for these patients. Univariate analysis was done to compare those risk factors associated with specific arrhythmias in the setting of congenital heart disease. Next, regression analysis was done to identify what patient characteristics and comorbidities were associated with increased risk of specific arrhythmias. A total of 52,725,227 admissions were included in the analysis. Of these, 109,168 (0.21%) had congenital heart disease. Of those with congenital heart disease, 27,088 (25%) had an arrhythmia at some point. The most common arrhythmia in those with congenital heart disease was atrial fibrillation, which was noted in 86% of those with arrhythmia followed by atrial flutter which was noted in 20% of those with congenital heart disease. The largest burden of arrhythmia was found to be in those with tricuspid atresia with a 51% prevalence of arrhythmia in this group followed by Ebstein anomaly which had an arrhythmia prevalence of 39%. Increasing age, male gender, double outlet right ventricle, atrioventricular septal defect, heart failure, obstructive sleep apnea, transposition of the great arteries, congenitally corrected transposition, and tetralogy of Fallot were frequently noted to be independent risk factors of specific arrhythmias. Approximately, 25% of adult admissions with congenital heart disease are associated with arrhythmia. The burden of arrhythmia varies by the specific lesion and other risk factors as well. Understanding of these can help in risk stratification and can help devise strategies to lower this risk. © 2016 Wiley Periodicals, Inc.

  17. Recognizing an Irregular Heart Rhythm

    MedlinePlus

    ... a workout, consider checking your rhythm as well. Atrial fibrillation, also referred to as AF, is a common ... upper chambers, or atria, of the heart. “While atrial fibrillation is not common among young people, it can ...

  18. Association of Warfarin Use With Lower Overall Cancer Incidence Among Patients Older Than 50 Years.

    PubMed

    Haaland, Gry S; Falk, Ragnhild S; Straume, Oddbjørn; Lorens, James B

    2017-12-01

    In cancer models, warfarin inhibits AXL receptor tyrosine kinase-dependent tumorigenesis and enhances antitumor immune responses at doses not reaching anticoagulation levels. This study investigates the association between warfarin use and cancer incidence in a large, unselected population-based cohort. To examine the association between warfarin use and cancer incidence. This population-based cohort study with subgroup analysis used the Norwegian National Registry coupled with the Norwegian Prescription Database and the Cancer Registry of Norway. The cohort comprised all persons (N = 1 256 725) born between January 1, 1924, and December 31, 1954, who were residing in Norway from January 1, 2006, through December 31, 2012. The cohort was divided into 2 groups-warfarin users and nonusers; persons taking warfarin for atrial fibrillation or atrial flutter were the subgroup. Data were collected from January 1, 2004, to December 31, 2012. Data analysis was conducted from October 15, 2016, to January 31, 2017. Warfarin use was defined as taking at least 6 months of a prescription and at least 2 years from first prescription to any cancer diagnosis. If warfarin treatment started after January 1, 2006, each person contributed person-time in the nonuser group until the warfarin user criteria were fulfilled. Cancer diagnosis of any type during the 7-year observation period (January 1, 2006, through December 31, 2012). Of the 1 256 725 persons in the cohort, 607 350 (48.3%) were male, 649 375 (51.7%) were female, 132 687 (10.6%) had cancer, 92 942 (7.4%) were classified as warfarin users, and 1 163 783 (92.6%) were classified as nonusers. Warfarin users were older, with a mean (SD) age of 70.2 (8.2) years, and were predominantly men (57 370 [61.7%]) as compared with nonusers, who had a mean (SD) age of 63.9 (8.6) years and were mostly women (613 803 [52.7%]). Among warfarin users and compared with nonusers, there was a significantly lower age- and sex-adjusted incidence rate ratio (IRR) in all cancer sites (IRR, 0.84; 95% CI, 0.82-0.86) and in prevalent organ-specific sites (lung, 0.80 [95% CI, 0.75-0.86]; prostate, 0.69 [95% CI, 0.65-0.72]; and breast, 0.90 [95% CI, 0.82-1.00]). There was no observed significant effect in colon cancer (IRR, 0.99; 95% CI, 0.93-1.06). In a subgroup analysis of patients with atrial fibrillation or atrial flutter, the IRR was lower in all cancer sites (IRR, 0.62; 95% CI, 0.59-0.65) and in prevalent sites (lung, 0.39 [95% CI, 0.33-0.46]; prostate, 0.60 [95% CI, 0.55-0.66]; breast, 0.72 [95% CI, 0.59-0.87]; and colon, 0.71 [95% CI, 0.63-0.81]). Warfarin use may have broad anticancer potential in a large, population-based cohort of persons older than 50 years. This finding could have important implications for the selection of medications for patients needing anticoagulation.

  19. Large-scale analyses of common and rare variants identify 12 new loci associated with atrial fibrillation

    PubMed Central

    Christophersen, Ingrid E.; Rienstra, Michiel; Roselli, Carolina; Yin, Xiaoyan; Geelhoed, Bastiaan; Barnard, John; Lin, Honghuang; Arking, Dan E.; Smith, Albert V.; Albert, Christine M.; Chaffin, Mark; Tucker, Nathan R.; Li, Molong; Klarin, Derek; Bihlmeyer, Nathan A; Low, Siew-Kee; Weeke, Peter E.; Müller-Nurasyid, Martina; Smith, J. Gustav; Brody, Jennifer A.; Niemeijer, Maartje N.; Dörr, Marcus; Trompet, Stella; Huffman, Jennifer; Gustafsson, Stefan; Schurman, Claudia; Kleber, Marcus E.; Lyytikäinen, Leo-Pekka; Seppälä, Ilkka; Malik, Rainer; Horimoto, Andrea R. V. R.; Perez, Marco; Sinisalo, Juha; Aeschbacher, Stefanie; Thériault, Sébastien; Yao, Jie; Radmanesh, Farid; Weiss, Stefan; Teumer, Alexander; Choi, Seung Hoan; Weng, Lu-Chen; Clauss, Sebastian; Deo, Rajat; Rader, Daniel J.; Shah, Svati; Sun, Albert; Hopewell, Jemma C.; Debette, Stephanie; Chauhan, Ganesh; Yang, Qiong; Worrall, Bradford B.; Paré, Guillaume; Kamatani, Yoichiro; Hagemeijer, Yanick P.; Verweij, Niek; Siland, Joylene E.; Kubo, Michiaki; Smith, Jonathan D.; Van Wagoner, David R.; Bis, Joshua C.; Perz, Siegfried; Psaty, Bruce M.; Ridker, Paul M.; Magnani, Jared W.; Harris, Tamara B.; Launer, Lenore J.; Shoemaker, M. Benjamin; Padmanabhan, Sandosh; Haessler, Jeffrey; Bartz, Traci M.; Waldenberger, Melanie; Lichtner, Peter; Arendt, Marina; Krieger, Jose E.; Kähönen, Mika; Risch, Lorenz; Mansur, Alfredo J.; Peters, Annette; Smith, Blair H.; Lind, Lars; Scott, Stuart A.; Lu, Yingchang; Bottinger, Erwin B.; Hernesniemi, Jussi; Lindgren, Cecilia M.; Wong, Jorge; Huang, Jie; Eskola, Markku; Morris, Andrew P.; Ford, Ian; Reiner, Alex P.; Delgado, Graciela; Chen, Lin Y.; Chen, Yii-Der Ida; Sandhu, Roopinder K.; Li, Man; Boerwinkle, Eric; Eisele, Lewin; Lannfelt, Lars; Rost, Natalia; Anderson, Christopher D.; Taylor, Kent D.; Campbell, Archie; Magnusson, Patrik K.; Porteous, David; Hocking, Lynne J.; Vlachopoulou, Efthymia; Pedersen, Nancy L.; Nikus, Kjell; Orho-Melander, Marju; Hamsten, Anders; Heeringa, Jan; Denny, Joshua C.; Kriebel, Jennifer; Darbar, Dawood; Newton-Cheh, Christopher; Shaffer, Christian; Macfarlane, Peter W.; Heilmann, Stefanie; Almgren, Peter; Huang, Paul L.; Sotoodehnia, Nona; Soliman, Elsayed Z.; Uitterlinden, Andre G.; Hofman, Albert; Franco, Oscar H.; Völker, Uwe; Jöckel, Karl-Heinz; Sinner, Moritz F.; Lin, Henry J.; Guo, Xiuqing; Dichgans, Martin; Ingelsson, Erik; Kooperberg, Charles; Melander, Olle; Loos, Ruth J. F.; Laurikka, Jari; Conen, David; Rosand, Jonathan; van der Harst, Pim; Lokki, Marja-Liisa; Kathiresan, Sekar; Pereira, Alexandre; Jukema, J. Wouter; Hayward, Caroline; Rotter, Jerome I.; März, Winfried; Lehtimäki, Terho; Stricker, Bruno H.; Chung, Mina K.; Felix, Stephan B.; Gudnason, Vilmundur; Alonso, Alvaro; Roden, Dan M.; Kääb, Stefan; Chasman, Daniel I.; Heckbert, Susan R.; Benjamin, Emelia J.; Tanaka, Toshihiro; Lunetta, Kathryn L.; Lubitz, Steven A.; Ellinor, Patrick T.

    2017-01-01

    Atrial fibrillation affects more than 33 million people worldwide and increases the risk of stroke, heart failure, and death.1,2 Fourteen genetic loci have been associated with atrial fibrillation in European and Asian ancestry groups.3–7 To further define the genetic basis of atrial fibrillation, we performed large-scale, multi-racial meta-analyses of common and rare variant association studies. The genome-wide association studies (GWAS) included 18,398 individuals with atrial fibrillation and 91,536 referents; the exome-wide association studies (ExWAS) and rare variant association studies (RVAS) involved 22,806 cases and 132,612 referents. We identified 12 novel genetic loci that exceeded genome-wide significance, implicating genes involved in cardiac electrical and structural remodeling. Our results nearly double the number of known genetic loci for atrial fibrillation, provide insights into the molecular basis of atrial fibrillation, and may facilitate new potential targets for drug discovery.8 PMID:28416818

  20. Orthogonal P-wave morphology is affected by intra-atrial pressures.

    PubMed

    Petersson, Richard; Smith, J Gustav; Larsson, David A; Reitan, Öyvind; Carlson, Jonas; Platonov, Pyotr; Holmqvist, Fredrik

    2017-12-06

    It has previously been shown that the morphology of the P-wave neither depends on atrial size in healthy subjects with physiologically enlarged atria nor on the physiological anatomical variation in transverse orientation of the left atrium. The present study aimed to investigate if different pressures in the left and right atrium are associated with different P-wave morphologies. 38 patients with isolated, increased left atrial pressure, 51 patients with isolated, increased right atrial pressure and 76 patients with biatrially increased pressure were studied. All had undergone right heart catheterization and had 12-lead electrocardiographic recordings, which were transformed into vectorcardiograms for detailed P-wave morphology analysis. Normal P-wave morphology (type 1) was more common in patients with isolated increased pressure in the right atrium while abnormal P-wave morphology (type 2) was more common in the groups with increased left atrial pressure (P = 0.032). Moreover, patients with increased left atrial pressure, either isolated or in conjunction with increased right atrial pressure, had significantly more often a P-wave morphology with a positive deflection in the sagittal plane (P = 0.004). Isolated elevated right atrial pressure was associated with normal P-wave morphology while left-sided atrial pressure elevation, either isolated or in combination with right atrial pressure elevation, was associated with abnormal P-wave morphology.

  1. Real-time flutter analysis of an active flutter-suppression system on a remotely piloted research aircraft

    NASA Technical Reports Server (NTRS)

    Gilyard, G. B.; Edwards, J. W.

    1983-01-01

    Flight flutter-test results of the first aeroelastic research wing (ARW-1) of NASA's drones for aerodynamic and structural testing program are presented. The flight-test operation and the implementation of the active flutter-suppression system are described as well as the software techniques used to obtain real-time damping estimates and the actual flutter testing procedure. Real-time analysis of fast-frequency aileron excitation sweeps provided reliable damping estimates. The open-loop flutter boundary was well defined at two altitudes; a maximum Mach number of 0.91 was obtained. Both open-loop and closed-loop data were of exceptionally high quality. Although the flutter-suppression system provided augmented damping at speeds below the flutter boundary, an error in the implementation of the system resulted in the system being less stable than predicted. The vehicle encountered system-on flutter shortly after crossing the open-loop flutter boundary on the third flight and was lost. The aircraft was rebuilt. Changes made in real-time test techniques are included.

  2. Atrial fibrillation and hyperthyroidism: A literature review.

    PubMed

    Reddy, Vivek; Taha, Wael; Kundumadam, Shanker; Khan, Mazhar

    Atrial fibrillation is the most common arrhythmia worldwide with increasing frequency noted with age. Hyperthyroidism is a well-known cause of atrial fibrillation with a 16%-60% prevalence of atrial fibrillation in patients with known hyperthyroidism Ross et al. (2016). While hyperthyroidism as a causative factor of atrial fibrillation is well established, this literature review aims to answer several questions on this topic including: 1. The relationship of atrial fibrillation to hyperthyroidism 2. Atrial fibrillation as a predictor of hyperthyroidism 3. The pathophysiology of thyrotoxic atrial fibrillation 4. Subclinical hyperthyroidism and the relationship with atrial fibrillation 5. Cardioversion and Catheter ablation of hyperthyroid patients with atrial fibrillation 6. Thrombotic risk of hyperthyroid patients with atrial fibrillation 7. Management of Thyrotoxic Atrial fibrillation 8. Pharmacological rhythm control in patients with hyperthyroidism and atrial fibrillation 9. Treatment of Hyperthyroidism to prevent atrial fibrillation 10. Clinical Implications of Hyperthyroidism and Atrial Fibrillation. Copyright © 2017 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  3. Flutter analysis using transversality theory

    NASA Technical Reports Server (NTRS)

    Afolabi, D.

    1993-01-01

    A new method of calculating flutter boundaries of undamped aeronautical structures is presented. The method is an application of the weak transversality theorem used in catastrophe theory. In the first instance, the flutter problem is cast in matrix form using a frequency domain method, leading to an eigenvalue matrix. The characteristic polynomial resulting from this matrix usually has a smooth dependence on the system's parameters. As these parameters change with operating conditions, certain critical values are reached at which flutter sets in. Our approach is to use the transversality theorem in locating such flutter boundaries using this criterion: at a flutter boundary, the characteristic polynomial does not intersect the axis of the abscissa transversally. Formulas for computing the flutter boundaries and flutter frequencies of structures with two degrees of freedom are presented, and extension to multi-degree of freedom systems is indicated. The formulas have obvious applications in, for instance, problems of panel flutter at supersonic Mach numbers.

  4. Flutter of a Low-Aspect-Ratio Rectangular Wing

    NASA Technical Reports Server (NTRS)

    Cole, Stanley R.

    1989-01-01

    A flutter test of a low-aspect-ratio rectangular wing was conducted in the Langley Transonic Dynamics Tunnel (TDT). The model used in this flutter test consisted of a rigid wing mounted to the wind-tunnel wall by a flexible, rectangular beam. The flexible support shaft was connected to the wing root and was cantilever mounted to the wind-tunnel wall. The wing had an aspect ratio of 1.5 based on the wing semispan and an NACA 64A010 airfoil shape. The flutter boundary of the model was determined for a Mach number range of 0.5 to 0.97. The shape of the transonic flutter boundary was determined. Actual flutter points were obtained on both the subsonic and supersonic sides of the flutter bucket. The model exhibited a deep transonic flutter bucket over a narrow range of Mach number. At some Mach numbers, the flutter conditions were extrapolated using a subcritical response technique. In addition to the basic configuration, modifications were made to the model structure such that the first bending frequency was changed without significantly affecting the first torsion frequency. The experiment showed that increasing the bending stiffness of the model support shaft through these modifications lowered the flutter dynamic pressure. Flutter analysis was conducted for the basic model as a comparison with the experimental results. This flutter analysis was conducted with subsonic lifting-surface (kernel function) aerodynamics using the k method for the flutter solution.

  5. Left Atrial Anatomy in Patients Undergoing Ablation for Atrial Fibrillation.

    PubMed

    Krum, David; Hare, John; Gilbert, Carol; Choudhuri, Indrajit; Mori, Naoyo; Sra, Jasbir

    2013-01-01

    Background: Left atrial anatomy is highly variable, asymmetric, irregular and three-dimensionally unique. This variability can affect the outcome of atrial ablation. A catalog of anatomic varieties may aid patient selection and ablation approach and provide better tools for left atrial ablation. Methods: We analyzed computed tomography scans from 514 patients undergoing left atrial ablation. Images were processed on Advantage Windows with CardEP™ software (GE Healthcare, Waukesha, WI). Measurements of pulmonary vein (PV) ostial size along the long and short axes were made using double oblique cuts, and area of the ostia was calculated. Results: Patients with 2 left (LPV) and 2 right PVs (RPV) (62.6%), 2 LPVs and 3 RPVs (17.3%) and 1 LPV and 2 RPVs (14.2%) made up the three most common variants. In the 2-LPV/2-RPV anatomy, the ostial size and area of the RPVs were larger than their corresponding LPVs (p<0.001), and the ostial size and area of the superior PVs were larger than their corresponding inferior PVs (p<0.001). In the 2-LPV/3-RPV anatomy, the total area of the RPVs was larger than the total area of the LPVs (p<0.001). In the 1-LPV/2-RPV anatomy, the ostial size of the left common PV was larger than either right PV (p<0.007). However, the total area of the RPVs was larger than the area of the left common PV (p<0.002). The left common PV was also larger than any of the left veins in any of the other anatomies. The total PV area between the three most common anatomies was not significantly different. Conclusions: More than 37% of patients have a left atrial anatomy other than 2 left and 2 right PVs. This data may help in designing approaches for left atrial ablation, tailoring the procedure to individual patients and improving ablation tools.

  6. The AFFORD clinical decision aid to identify emergency department patients with atrial fibrillation at low risk for 30-day adverse events.

    PubMed

    Barrett, Tyler W; Storrow, Alan B; Jenkins, Cathy A; Abraham, Robert L; Liu, Dandan; Miller, Karen F; Moser, Kelly M; Russ, Stephan; Roden, Dan M; Harrell, Frank E; Darbar, Dawood

    2015-03-15

    There is wide variation in the management of patients with atrial fibrillation (AF) in the emergency department (ED). We aimed to derive and internally validate the first prospective, ED-based clinical decision aid to identify patients with AF at low risk for 30-day adverse events. We performed a prospective cohort study at a university-affiliated tertiary-care ED. Patients were enrolled from June 9, 2010, to February 28, 2013, and followed for 30 days. We enrolled a convenience sample of patients in ED presenting with symptomatic AF. Candidate predictors were based on ED data available in the first 2 hours. The decision aid was derived using model approximation (preconditioning) followed by strong bootstrap internal validation. We used an ordinal outcome hierarchy defined as the incidence of the most severe adverse event within 30 days of the ED evaluation. Of 497 patients enrolled, stroke and AF-related death occurred in 13 (3%) and 4 (<1%) patients, respectively. The decision aid included the following: age, triage vitals (systolic blood pressure, temperature, respiratory rate, oxygen saturation, supplemental oxygen requirement), medical history (heart failure, home sotalol use, previous percutaneous coronary intervention, electrical cardioversion, cardiac ablation, frequency of AF symptoms), and ED data (2 hours heart rate, chest radiograph results, hemoglobin, creatinine, and brain natriuretic peptide). The decision aid's c-statistic in predicting any 30-day adverse event was 0.7 (95% confidence interval 0.65, 0.76). In conclusion, in patients with AF in the ED, Atrial Fibrillation and Flutter Outcome Risk Determination provides the first evidence-based decision aid for identifying patients who are at low risk for 30-day adverse events and candidates for safe discharge. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias.

    PubMed

    Bauernfeind, Tamas; Akca, Ferdi; Schwagten, Bruno; de Groot, Natasja; Van Belle, Yves; Valk, Suzanne; Ujvari, Barbara; Jordaens, Luc; Szili-Torok, Tamas

    2011-07-01

    We aimed to evaluate the safety and long-term efficacy of the magnetic navigation system (MNS) in a large number of patients. The MNS has the potential for improving safety and efficacy based on atraumatic catheter design and superior navigation capabilities. In this study, 610 consecutive patients underwent ablation. Patients were divided into two age- and sex-matched groups. Ablations were performed either using MNS (group MNS, 292) or conventional manual ablation [group manual navigation (MAN), 318]. The following parameters were analysed: acute success rate, fluoroscopy time, procedure time, complications [major: pericardial tamponade, permanent atrioventricular (AV) block, major bleeding, and death; minor: minor bleeding and temporary AV block]. Recurrence rate was assessed during follow-up (15±9.5 months). Subgroup analysis was performed for the following groups: atrial fibrillation, isthmus dependent and atypical atrial flutter, atrial tachycardia, AV nodal re-entrant tachycardia, circus movement tachycardia, and ventricular tachycardia (VT). Magnetic navigation system was associated with less major complications (0.34 vs. 3.2%, P=0.01). The total numbers of complications were lower in group MNS (4.5 vs. 10%, P=0.005). Magnetic navigation system was equally effective as MAN in acute success rate for overall groups (92 vs. 94%, P=ns). Magnetic navigation system was more successful for VTs (93 vs. 72%, P<0.05). Less fluoroscopy was used in group MNS (30±20 vs. 35±25 min, P<0.01). There were no differences in procedure times and recurrence rates for the overall groups (168±67 vs. 159±75 min, P=ns; 14 vs. 11%, P=ns; respectively). Our data suggest that the use of MNS improves safety without compromising efficiency of ablations. Magnetic navigation system is more effective than manual ablation for VTs.

  8. Pharmacologic Prevention of Incident Atrial Fibrillation: Long-Term Results From the ALLHAT (Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial).

    PubMed

    Dewland, Thomas A; Soliman, Elsayed Z; Yamal, Jose-Miguel; Davis, Barry R; Alonso, Alvaro; Albert, Christine M; Simpson, Lara M; Haywood, L Julian; Marcus, Gregory M

    2017-12-01

    Although atrial fibrillation (AF) guidelines indicate that pharmacological blockade of the renin-angiotensin system may be considered for primary AF prevention in hypertensive patients, previous studies have yielded conflicting results. We sought to determine whether randomization to lisinopril reduces incident AF or atrial flutter (AFL) compared with chlorthalidone in a large clinical trial cohort with extended post-trial surveillance. We performed a secondary analysis of the ALLHAT (Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial), a randomized, double-blind, active-controlled clinical trial that enrolled hypertensive individuals ≥55 years of age with at least one other cardiovascular risk factor. Participants were randomly assigned to receive amlodipine, lisinopril, or chlorthalidone. Individuals with elevated fasting low-density lipoprotein cholesterol levels were also randomized to pravastatin versus usual care. The primary outcome was the development of either AF or AFL as diagnosed by serial study ECGs or by Medicare claims data. Among 14 837 participants without prevalent AF or AFL, 2514 developed AF/AFL during a mean 7.5±3.2 years of follow-up. Compared with chlorthalidone, randomization to either lisinopril (hazard ratio, 1.04; 95% confidence interval, 0.94-1.15; P =0.46) or amlodipine (hazard ratio, 0.93; 95% confidence interval, 0.84-1.03; P =0.16) was not associated with a significant reduction in incident AF/AFL. Compared with chlorthalidone, treatment with lisinopril is not associated with a meaningful reduction in incident AF or AFL among older adults with a history of hypertension. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00000542. © 2017 American Heart Association, Inc.

  9. Dexmedetomidine-related atrial standstill and loss of capture in a pediatric patient after congenital heart surgery.

    PubMed

    Shepard, Suzanne M; Tejman-Yarden, Shai; Khanna, Sandeep; Davis, Christopher K; Batra, Anjan S

    2011-01-01

    Dexmedetomidine (DEX; Precedex) is an alpha-2 adrenergic receptor agonist that produces anxiolysis and sleep-like sedation without narcosis or respiratory depression and has relatively few cardiovascular side effects. Given its favorable sedative properties combined with its limited effects on hemodynamic and respiratory function, it is widely used in pediatric intensive care and anesthesia settings. Case report. Pediatric intensive care unit. A three-yr-old girl was admitted after mitral valve replacement for persistent severe mitral insufficiency. Her prior history was significant for tetralogy of Fallot which was repaired at nine months of age. A year later the patient developed mitral and tricuspid valve insufficiency and subsequently underwent mitral and tricuspid valve repair, pulmonary valve replacement, and a maze procedure (the latter was performed for persistent atrial flutter). Following that operation she developed sinus node dysfunction and had a permanent epicardial dual-chamber pacemaker implanted. Due to remaining severe mitral insufficiency the patient had increasing pulmonary symptoms, necessitating the most recent surgery to replace her mitral valve. On postoperative day two the patient was hemodynamically stable and weaning off mechanical ventilation. Tracheal extubation was anticipated to occur within the next 24 hrs. A DEX infusion of 0.6 mcg/kg/hr was initiated. A pacemaker interrogation performed on postoperative day three, 21 hrs after the initiation of DEX, revealed unsuccessful atrial capture. Dexmedetomidine was subsequently discontinued and the patient's pacemaker was reinterrogated. The interrogation findings were similar to those seen prior to the initiation of DEX. As a result of these findings, caution is warranted in the administration of DEX to patients with predisposing conduction abnormalities and patients who are pacemaker-dependent.

  10. Electrocardiogram changes and atrial arrhythmias in individuals carrying sodium channel SCN5A D1275N mutation.

    PubMed

    Vanninen, Sari U M; Nikus, Kjell; Aalto-Setälä, Katriina

    2017-09-01

    The cardiac sodium channel SCN5A regulates atrioventricular and ventricular depolarization as well as cardiac conduction. Patients with cardiac electrical abnormalities have an increased risk of sudden cardiac death (SCD) and cardio-embolic stroke. Optimal management of cardiac disease includes the understanding of association between the causative mutations and the clinical phenotype. A 12-lead electrocardiogram (ECG) is an easy and inexpensive tool for finding risk patients. A blood sample for DNA extraction was obtained in a Finnish family with 43 members; systematic 12-lead ECG analysis was performed in 13 of the family members carrying an SCN5A D1275N mutation. Conduction defects and supraventricular arrhythmias, including atrial fibrillation/flutter, atrioventricular nodal re-entry tachycardia (AVNRT) and junctional rhythm were searched for. Five (38%) mutation carriers had fascicular or bundle branch block, 10 had atrial arrhythmias; no ventricular arrhythmias were found. Notching of the R- and S waves - including initial QRS fragmentation - and prolonged S-wave upstroke were present in all the affected family members. Notably, four (31%) affected family members had a stroke before the age of 31 and two experienced premature death. A 12-lead ECG can be used to predict arrhythmias in SCN5A D1275N mutation carriers. Key messages The 12-lead ECG may reveal cardiac abnormalities even before clinical symptoms occur. Specific ECG findings - initial QRS fragmentation, prolonged S-wave upstroke as well as supraventricular arrhythmias - were frequently encountered in all SCN5A D1257N mutation carriers. ECG follow-up is recommended for all SCN5A D1275N mutation carriers.

  11. Results of Two Free-fall Experiments on Flutter of Thin Unswept Wings in the Transonic Speed Range

    NASA Technical Reports Server (NTRS)

    Lauten, William T , Jr; Nelson, Herbert C

    1957-01-01

    Results of four thin, unswept, flutter airfoils attached to two freely falling bodies are reported. Two airfoils fluttered at a Mach number of 0.85, a third airfoil fluttered at a Mach number of 1.03, and a fourth fluttered at a Mach number of 1.07. Results of calculations of flutter speed using incompressible and compressible air-force coefficients, including a Mach number of 1.0, are presented.

  12. The wearable cardioverter-defibrillator in a real-world clinical setting: experience in 102 consecutive patients.

    PubMed

    Erath, Julia W; Vamos, Mate; Sirat, Abdul Sami; Hohnloser, Stefan H

    2017-04-01

    The wearable cardioverter-defibrillator (WCD) is used for temporary protection of patients deemed to be at high risk for sudden death (SCD) not yet meeting indications for the implantable defibrillator (ICD). To evaluate the efficacy, safety, and compliance of/to WCD use and subsequent medium-term outcome of patients in a single-center observational study. A total of 102 consecutive patients were fitted with the WCD from 2012 to 2015 and followed for a mean of 11 months (±8 months). The most common clinical indication for WCD-prescription (63%) was a new diagnosis of severely impaired LV function (LVEF ≤35%). The median wear time of the WCD was 54 days with a daily use of 23 h. Appropriate WCD therapy occurred in four patients (seven shocks for VF, one shock for VT). An ICD was finally implanted in 56 patients (55%). Improvement in LV function was the most common reason not to implant an ICD (HR 0.37; 95% CI 0.19-0.73; p = 0.004). Two patients had inappropriate shocks from their WCD due to atrial fibrillation/flutter. Five patients fitted with an ICD after the end of WCD therapy suffered VT/VF episodes. After wearing the WCD, six patients died (five ICD recipients and one non-ICD recipient). WCD therapy was well accepted by patients and provided temporary protection against ventricular tachyarrhythmias in patients at risk for SCD. The WCD may help to avoid unnecessary ICD implantations in a significant proportion of patients.

  13. Study of flutter related computational procedures for minimum weight structural sizing of advanced aircraft, supplemental data

    NASA Technical Reports Server (NTRS)

    Oconnell, R. F.; Hassig, H. J.; Radovcich, N. A.

    1975-01-01

    Computational aspects of (1) flutter optimization (minimization of structural mass subject to specified flutter requirements), (2) methods for solving the flutter equation, and (3) efficient methods for computing generalized aerodynamic force coefficients in the repetitive analysis environment of computer-aided structural design are discussed. Specific areas included: a two-dimensional Regula Falsi approach to solving the generalized flutter equation; method of incremented flutter analysis and its applications; the use of velocity potential influence coefficients in a five-matrix product formulation of the generalized aerodynamic force coefficients; options for computational operations required to generate generalized aerodynamic force coefficients; theoretical considerations related to optimization with one or more flutter constraints; and expressions for derivatives of flutter-related quantities with respect to design variables.

  14. Flutter parametric studies of cantilevered twin-engine transport type wing with and without winglet. Volume 2: Transonic and density effect investigations

    NASA Technical Reports Server (NTRS)

    Bhatia, K. G.; Nagaraja, K. S.

    1984-01-01

    Flutter characteristics of a cantilevered high aspect ratio wing with winglet were investigated. The configuration represented a current technology, twin engine airplane. Compressibility effects through transonic Mach numbers and a wide range of mass-density ratios were evaluated on a low speed and high speed model. Four flutter mechanisms were obtained from test, and analysis from various combinations of configuration parameters. It is shown that the coupling between wing tip vertical and chordwise motions have significant effect under some conditions. It is concluded that for the flutter model configurations studied, the winglet related flutter is amenable to the conventional flutter analysis techniques. The low speed model flutter and the high-speed model flutter results are described.

  15. Status of wing flutter

    NASA Technical Reports Server (NTRS)

    Kussner, H G

    1936-01-01

    This report presents a survey of previous theoretical and experimental investigations on wing flutter covering thirteen cases of flutter observed on airplanes. The direct cause of flutter is, in the majority of cases, attributable to (mass-) unbalanced ailerons. Under the conservative assumption that the flutter with the phase angle most favorable for excitation occurs only in two degrees of freedom, the lowest critical speed can be estimated from the data obtained on the oscillation bench. Corrective measures for increasing the critical speed and for definite avoidance of wing flutter, are discussed.

  16. RR-Interval variance of electrocardiogram for atrial fibrillation detection

    NASA Astrophysics Data System (ADS)

    Nuryani, N.; Solikhah, M.; Nugoho, A. S.; Afdala, A.; Anzihory, E.

    2016-11-01

    Atrial fibrillation is a serious heart problem originated from the upper chamber of the heart. The common indication of atrial fibrillation is irregularity of R peak-to-R-peak time interval, which is shortly called RR interval. The irregularity could be represented using variance or spread of RR interval. This article presents a system to detect atrial fibrillation using variances. Using clinical data of patients with atrial fibrillation attack, it is shown that the variance of electrocardiographic RR interval are higher during atrial fibrillation, compared to the normal one. Utilizing a simple detection technique and variances of RR intervals, we find a good performance of atrial fibrillation detection.

  17. Automatic Detection of Atrial Fibrillation Using Basic Shannon Entropy of RR Interval Feature

    NASA Astrophysics Data System (ADS)

    Afdala, Adfal; Nuryani, Nuryani; Satriyo Nugroho, Anto

    2017-01-01

    Atrial Fibrillation is one of heart disease, that common characterized by irregularity heart beat. Atrial fibrillation leads to severe complications such as cardiac failure with the subsequent risk of a stroke. A method to detect atrial fibrillation is needed to prevent a risk of atrial fibrillation. This research uses data from physionet in atrial fibrillation database category. The performance of Shannon entropy has the highest accuracy if a threshold is 0.5 with accuracy 89.79%, sensitivity 91.04% and specificity 89.01%. Based on the result we get a conclusion, the ability of Shannon entropy to detect atrial fibrillation is good.

  18. Influence of Shock Wave on the Flutter Behavior of Fan Blades Investigated

    NASA Technical Reports Server (NTRS)

    Srivastava, Rakesh; Bakhle, Milind A.; Stefko, George L.

    2003-01-01

    Modern fan designs have blades with forward sweep; a lean, thin cross section; and a wide chord to improve performance and reduce noise. These geometric features coupled with the presence of a shock wave can lead to flutter instability. Flutter is a self-excited dynamic instability arising because of fluid-structure interaction, which causes the energy from the surrounding fluid to be extracted by the vibrating structure. An in-flight occurrence of flutter could be catastrophic and is a significant design issue for rotor blades in gas turbines. Understanding the flutter behavior and the influence of flow features on flutter will lead to a better and safer design. An aeroelastic analysis code, TURBO, has been developed and validated for flutter calculations at the NASA Glenn Research Center. The code has been used to understand the occurrence of flutter in a forward-swept fan design. The forward-swept fan, which consists of 22 inserted blades, encountered flutter during wind tunnel tests at part speed conditions.

  19. Ruptured pericardial perivascular epithelioid cell tumor (PEComa) leading to sudden death: an autopsy case report and review of the literature.

    PubMed

    Zhang, Lingxin; Carpenter, Danielle; Dehner, Louis P

    2016-01-01

    A 30-year-old man with past medical history of atrial fibrillation/flutter passed away after presenting with sudden-onset cardiac dysfunction. The postmortem examination revealed cardiac tamponade secondary to rupture of a 7.2-cm pericardial perivascular epithelioid cell tumor (PEComa). The tumor grossly appeared to arise from the transverse pericardial sinus and focally penetrated the epicardium of the right atrium. Microscopically, it was composed of predominately spindle cells with low nuclear grade, no pleomorphism, or readily apparent mitoses. Immunohistochemistry revealed cytoplasmic reactivity for HMB-45, desmin, and smooth muscle actin. Electron microscopic findings were characterized by melanosome-like structures intermixed with intermediate filaments and abundant stacked endoplasmic reticulum. The present case is unique among previously reported pericardial/myocardial PEComas as a first example resulting in unexpected cardiac tamponade and sudden cardiac death. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Appropriate and inappropriate use of dronedarone in 2013.

    PubMed

    Naccarelli, Gerald V

    2013-08-01

    Dronedarone is a multichannel blocking antiarrhythmic agent that has been shown to prevent atrial fibrillation/flutter (AF/AFl) recurrences in several multi-center trials. In the ANDROMEDA trial, dronedarone treatment increased mortality and cardiovascular hospitalizations patients with decompensated heart failure. In the ATHENA trial, dronedarone was used in elderly high risk patients with paroxysmal or persistent AF/AFl, excluding those with advanced heart failure, cardiovascular hospitalizations were significantly reduced. Dronedarone increased mortality and cardiovascular hospitalizations in a different patient group with permanent AF/AFl. Although organic toxicity from the drug is very rare, post-marketing data has reported rare hepatic toxicity associated with dronedarone use. Current guidelines position dronedarone as a front-line antiarrhythmic in many patients with AF/Fl. However, dronedarone should not be used in patients with advanced heart failure or in permanent AF. Clinical trial results have helped us define appropriate and inappropriate candidates for dronedarone.

  1. Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.

    PubMed

    Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek

    2003-05-01

    Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.

  2. Management of atrial fibrillation.

    PubMed

    Moukabary, Talal; Gonzalez, Mario D

    2015-07-01

    Atrial fibrillation is a very common clinical problem with a high prevalence that is expected to rise over time because of increasing risk factors (eg, age, obesity, hypertension). This high prevalence is also associated with high cost, because atrial fibrillation represents about 1% of overall health care spending. The management of atrial fibrillation involves multiple facets: (1) management of underlying disease if present and the management of atrial fibrillation risk factors, (2) prevention of thromboembolism, (3) control of the ventricular rate during atrial fibrillation, and (4) restoration and maintenance of normal sinus rhythm. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Heart failure and atrial fibrillation: current concepts and controversies.

    PubMed Central

    Van den Berg, M. P.; Tuinenburg, A. E.; Crijns, H. J.; Van Gelder, I. C.; Gosselink, A. T.; Lie, K. I.

    1997-01-01

    Heart failure and atrial fibrillation are very common, particularly in the elderly. Owing to common risk factors both disorders are often present in the same patient. In addition, there is increasing evidence of a complex, reciprocal relation between heart failure and atrial fibrillation. Thus heart failure may cause atrial fibrillation, with electromechanical feedback and neurohumoral activation playing an important mediating role. In addition, atrial fibrillation may promote heart failure; in particular, when there is an uncontrolled ventricular rate, tachycardiomyopathy may develop and thereby heart failure. Eventually, a vicious circle between heart failure and atrial fibrillation may form, in which neurohumoral activation and subtle derangement of rate control are involved. Treatment should aim at unloading of the heart, adequate control of ventricular rate, and correction of neurohumoral activation. Angiotensin converting enzyme inhibitors may help to achieve these goals. Treatment should also include an attempt to restore sinus rhythm through electrical cardioversion, though appropriate timing of cardioversion is difficult. His bundle ablation may be used to achieve adequate rate control in drug refractory cases. PMID:9155607

  4. Parametric Flutter Analysis of the TCA Configuration and Recommendation for FFM Design and Scaling

    NASA Technical Reports Server (NTRS)

    Baker, Myles; Lenkey, Peter

    1997-01-01

    The current HSR Aeroelasticity plan to design, build, and test a full span, free flying transonic flutter model in the TDT has many technical obstacles that must be overcome for a successful program. One technical obstacle is the determination of a suitable configuration and point in the sky to use in setting the scaling point for the ASE models program. Determining this configuration and point in the sky requires balancing several conflicting requirements, including model buildability, tunnel test safety, and the ability of the model to represent the flutter mechanisms of interest. As will be discussed in detail in subsequent sections, the current TCA design exhibits several flutter mechanisms of interest. It has been decided that the ASE models program will focus on the low frequency symmetric flutter mechanism, and will make no attempt to investigate high frequency flutter mechanisms. There are several reasons for this choice. First, it is believed that the high frequency flutter mechanisms are similar in nature to classical wing bending/torsion flutter, and therefore there is more confidence that this mechanism can be predicted using current techniques. The low frequency mode, on the other hand, is a highly coupled mechanism involving wing, body, tail, and engine motion which may be very difficult to predict. Second, the high frequency flutter modes result in very small weight penalties (several hundred pounds), while suppression of the low frequency mechanism inside the flight envelope causes thousands of pounds to be added to the structure. In order to successfully test the low frequency flutter mode of interest, a suitable starting configuration and point in the sky must be identified. The configuration and point in the sky must result in a wind tunnel model that (1) represents the low-frequency wing/body/engine/empennage flutter mechanisms that are unique to HSCT configurations, (2) flutters at an acceptably low frequency in the tunnel, (3) flutters at an acceptably low dynamic pressure in the tunnel, (4) allows sufficient weight for model buildability without inordinately high cost, and (5) has significant separation between the target flutter mechanism and other, potentially catastrophic, flutter mechanisms.

  5. Chocolate intake and risk of clinically apparent atrial fibrillation: the Danish Diet, Cancer, and Health Study.

    PubMed

    Mostofsky, Elizabeth; Berg Johansen, Martin; Tjønneland, Anne; Chahal, Harpreet S; Mittleman, Murray A; Overvad, Kim

    2017-08-01

    To evaluate the association between chocolate intake and incident clinically apparent atrial fibrillation or flutter (AF). The Danish Diet, Cancer, and Health Study is a large population-based prospective cohort study. The present study is based on 55 502 participants (26 400 men and 29 102 women) aged 50-64 years who had provided information on chocolate intake at baseline. Incident cases of AF were ascertained by linkage with nationwide registries. During a median of 13.5 years there were 3346 cases of AF. Compared with chocolate intake less than once per month, the rate of AF was lower for people consuming 1-3 servings/month (hazard ratio (HR) 0.90, 95% confidence interval (CI) 0.82 to 0.98), 1 serving/week (HR 0.83, 95% CI 0.74 to 0.92), 2-6 servings/week (HR 0.80, 95% CI 0.71 to 0.91) and ≥1 servings/day (HR 0.84, 95% CI 0.65 to 1.09; p-linear trend <0.0001), with similar results for men and women. Accumulating evidence indicates that moderate chocolate intake may be inversely associated with AF risk, although residual confounding cannot be ruled out. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Cardiac arrhythmias during or after epileptic seizures

    PubMed Central

    van der Lende, Marije; Surges, Rainer; Sander, Josemir W; Thijs, Roland D

    2016-01-01

    Seizure-related cardiac arrhythmias are frequently reported and have been implicated as potential pathomechanisms of Sudden Unexpected Death in Epilepsy (SUDEP). We attempted to identify clinical profiles associated with various (post)ictal cardiac arrhythmias. We conducted a systematic search from the first date available to July 2013 on the combination of two terms: ‘cardiac arrhythmias’ and ‘epilepsy’. The databases searched were PubMed, Embase (OVID version), Web of Science and COCHRANE Library. We attempted to identify all case reports and case series. We identified seven distinct patterns of (post)ictal cardiac arrhythmias: ictal asystole (103 cases), postictal asystole (13 cases), ictal bradycardia (25 cases), ictal atrioventricular (AV)-conduction block (11 cases), postictal AV-conduction block (2 cases), (post)ictal atrial flutter/atrial fibrillation (14 cases) and postictal ventricular fibrillation (3 cases). Ictal asystole had a mean prevalence of 0.318% (95% CI 0.316% to 0.320%) in people with refractory epilepsy who underwent video-EEG monitoring. Ictal asystole, bradycardia and AV-conduction block were self-limiting in all but one of the cases and seen during focal dyscognitive seizures. Seizure onset was mostly temporal (91%) without consistent lateralisation. Postictal arrhythmias were mostly found following convulsive seizures and often associated with (near) SUDEP. The contrasting clinical profiles of ictal and postictal arrhythmias suggest different pathomechanisms. Postictal rather than ictal arrhythmias seem of greater importance to the pathophysiology of SUDEP. PMID:26038597

  7. Optical measurement of unducted fan flutter

    NASA Technical Reports Server (NTRS)

    Kurkov, Anatole P.; Mehmed, Oral

    1990-01-01

    A nonintrusive optical method is described for flutter vibrations in unducted fan or propeller rotors and provides detailed spectral results for two flutter modes of a scaled unducted fan. The measurements were obtained in a high-speed wind tunnel. A single-rotor and a dual-rotor counterrotating configuration of the model were tested; however, only the forward rotor of the counterrotating configuration fluttered. Conventional strain gages were used to obtain flutter frequency; optical data provided complete phase results and an indication of the flutter mode shape through the ratio of the leading- to trailing-edge flutter amplitudes near the blade tip. In the transonic regime exhibited some features that are usually associated with nonlinear vibrations. Experimental mode shape and frequencies were compared with calculated values that included centrifugal effects.

  8. Flutter Research on Skin Panels

    NASA Technical Reports Server (NTRS)

    Kordes, Eldon E.; Tuovila, Weimer J.; Guy, Lawrence D.

    1960-01-01

    Representative experimental results are presented to show the current status of the panel flutter problem. Results are presented for unstiffened rectangular panels and for rectangular panels stiffened by corrugated backing. Flutter boundaries are established for all types of panels when considered on the basis of equivalent isotropic plates. The effects of Mach number, differential pressure, and aerodynamic heating on panel flutter are discussed. A flutter analysis of orthotropic panels is presented in the appendix.

  9. Subsonic/transonic stall flutter investigation of a rotating rig

    NASA Technical Reports Server (NTRS)

    Jutras, R. R.; Fost, R. B.; Chi, R. M.; Beacher, B. F.

    1981-01-01

    Stall flutter is investigated by obtaining detailed quantitative steady and aerodynamic and aeromechanical measurements in a typical fan rotor. The experimental investigation is made with a 31.3 percent scale model of the Quiet Engine Program Fan C rotor system. Both subsonic/transonic (torsional mode) flutter and supersonic (flexural) flutter are investigated. Extensive steady and unsteady data on the blade deformations and aerodynamic properties surrounding the rotor are acquired while operating in both the steady and flutter modes. Analysis of this data shows that while there may be more than one traveling wave present during flutter, they are all forward traveling waves.

  10. In-flight automated external defibrillator use and consultation patterns

    PubMed Central

    Brown, AM; Rittenberger, JC; Ammon, CM; Harrington, S; Guyette, FX

    2010-01-01

    Background Limited information exists about the in-flight use and outcomes associated with automatic external defibrillators (AED) on commercial airlines. Methods We collected self-reported cases of AED use to an airline consultation service from three US airlines between May 2004 and March 2009. We reviewed all available data files, related consult forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as: sinus, heart block, SVT, atrial fibrillation/flutter, asystole, PEA and VF/VT. Results There were a total of 169 AED applications with 40 cardiac arrests. The mean ages were 58 years (SD 15) and 63 years (SD 12) respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with initial rhythms of: sinus 114 (88%); atrial fibrillation/flutter 7 (5%); complete heart block 4 (3%); and SVT 4 (3%). Presenting rhythms among the cardiac arrest population were: asystole 16 (40%); ventricular fibrillation/ventricular tachycardia 10 (25%); and PEA 14 (35%). Fourteen patients were defibrillated including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT and no medical consult was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were 6 (15%; 95% CI 3–27%) survivors with 5 occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after CPR for a junctional rhythm. Survival in those with VF/VT was 5/10 (50%; 95% CI 14–86%). Medications were delivered twice. The median time to first shock was 19 (IQR 12–24) seconds from AED application. Medical consultation was obtained in 56 (33%) of the 169 AED cases and 14 (35%) of the cardiac arrests. Conclusion AEDs resulted in 50% survival among those with VT/VF in-flight and 14% overall survival for cardiac arrest. Survival is poor among patients presenting with non-shockable rhythms. AEDs are used extensively for in-flight monitoring with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests. PMID:20128705

  11. Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter.

    PubMed

    Arya, Arash; Kottkamp, Hans; Piorkowski, Christopher; Bollmann, Andreas; Gerdes-Li, Jin-Hong; Riahi, Sam; Esato, Masahiro; Hindricks, Gerhard

    2008-05-01

    A remote magnetic navigation system (MNS) is available and has been used with a 4-mm-tip magnetic catheter for radiofrequency (RF) ablation of some supraventricular and ventricular arrhythmias; however, it has not been evaluated for the ablation of cavotricuspid isthmus-dependent right atrial flutter (AFL). The present study evaluates the feasibility and efficiency of this system and the newly available 8-mm-tip magnetic catheter to perform RF ablation in patients with AFL. Twenty-six consecutive patients (23 men, mean age 64.6 +/- 9.6 years) underwent RF ablation using a remote MNS. RF ablation was performed with an 8-mm-tip magnetic catheter (70 degrees C, maximum power 70 W, 90 seconds). The endpoint of ablation was complete bidirectional isthmus block. To assess a possible learning curve, procedural data were compared between the first 14 (group 1) and the rest (group 2) of the patients. The initial rhythm during ablation was AFL in 20 (19 counterclockwise and 1 clockwise) and sinus rhythm in six patients. Due to technical issues, the ablation in the 18th patient could not be done with the MNS, and so we switched to conventional ablation. The remote magnetic navigation and ablation procedure was successful in 24 of the 25 (96%) remaining patients with AFL. In one patient (patient 2), conventional catheter was used to complete the isthmus block after termination of AFL. The procedure, preparation, ablation, and fluoroscopy times (median [range]) were 53 (30-130) minutes, 28 (10-65) minutes, 25 (12-78) minutes, and 7.5 (3.2-20.8) minutes, respectively. Patients in group 2 had shorter procedure (45 [30-70] min vs 80 [57-130] min, P = 0.0001), preparation (25 [10-30] min vs 42 [30-65] min, P = 0.0001), ablation (20 [12-40] min vs 31 [20-78] min, P = 0.002), and fluoroscopy (7.2 [3.2-12.2] min vs 11.0 [5.4-20.8] min, P = 0.014) times. No complication occurred during the procedure. Using a remote MNS and an 8-mm-tip magnetic catheter, ablation of AFL is feasible, safe, and effective. Our data suggest that there is a short learning curve for this procedure.

  12. Radiofrequency catheter ablation of Type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator.

    PubMed

    Feld, Gregory K

    2004-11-01

    Recent studies have demonstrated a high degree of efficacy of 8 mm electrode-tipped or saline-irrigated-tip catheters for ablation of atrial flutter (AFL). These catheters have a theoretical advantage as they produce a large ablation lesion. However, large-tip ablation catheters have a larger surface area and require a higher power radiofrequency (RF) generator with up to 100 W capacity to produce adequate ablation temperatures (50-60 degrees C). The potential advantages of a large-tip ablation catheter and high-power RF generator include the need for fewer energy applications, shorter procedure and fluoroscopy times, and greater efficacy. Therefore, the safety and efficacy of AFL ablation using 8 or 10 mm electrode catheters and a 100-W RF generator was studied using the Boston Scientific, Inc., EPT-1000 XP cardiac ablation system. There were 169 patients, aged 61 +/- 12 years involved. Acute end points were bidirectional isthmus block and no inducible AFL. Following ablation, patients were seen at 1, 3 and 6 months, with event monitoring performed weekly and for any symptoms. Three quality of life surveys were completed during follow-up. Acute success was achieved in 158 patients (93%), with 12 +/- 11 RF energy applications. The efficacy of 8 and 10 mm electrodes did not differ significantly. The number of RF energy applications (10 +/- 8 vs. 14 +/- 8) and ablation time (0.5 +/- 0.4 vs. 0.8 +/- 0.6 h) were less with 10 mm compared with 8 mm electrodes (p < 0.01). Of 158 patients with acute success, 42 were not evaluated at 6 months due to study exclusions. Of the 116 patients evaluated at 6 months, 112 (97%) had no AFL recurrence. Of those without AFL recurrence at 6 months, 95 and 93% were free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved quality of life scores (p < 0.05) and reduced anti-arrhythmic and rate control drug use (p < 0.05). Complications occurred in six out of 169 patients (3.6%) but there were no deaths. It was concluded that ablation of AFL with 8 or 10 mm electrode catheters and a high-power RF generator was safe, effective and improved quality of life. The number and duration of RF applications was lower with 10 mm compared with 8 mm electrode catheters.

  13. An analytical technique for predicting the characteristics of a flexible wing equipped with an active flutter-suppression system and comparison with wind-tunnel data

    NASA Technical Reports Server (NTRS)

    Abel, I.

    1979-01-01

    An analytical technique for predicting the performance of an active flutter-suppression system is presented. This technique is based on the use of an interpolating function to approximate the unsteady aerodynamics. The resulting equations are formulated in terms of linear, ordinary differential equations with constant coefficients. This technique is then applied to an aeroelastic model wing equipped with an active flutter-suppression system. Comparisons between wind-tunnel data and analysis are presented for the wing both with and without active flutter suppression. Results indicate that the wing flutter characteristics without flutter suppression can be predicted very well but that a more adequate model of wind-tunnel turbulence is required when the active flutter-suppression system is used.

  14. Labyrinth Seal Flutter Analysis and Test Validation in Support of Robust Rocket Engine Design

    NASA Technical Reports Server (NTRS)

    El-Aini, Yehia; Park, John; Frady, Greg; Nesman, Tom

    2010-01-01

    High energy-density turbomachines, like the SSME turbopumps, utilize labyrinth seals, also referred to as knife-edge seals, to control leakage flow. The pressure drop for such seals is order of magnitude higher than comparable jet engine seals. This is aggravated by the requirement of tight clearances resulting in possible unfavorable fluid-structure interaction of the seal system (seal flutter). To demonstrate these characteristics, a benchmark case of a High Pressure Oxygen Turbopump (HPOTP) outlet Labyrinth seal was studied in detail. First, an analytical assessment of the seal stability was conducted using a Pratt & Whitney legacy seal flutter code. Sensitivity parameters including pressure drop, rotor-to-stator running clearances and cavity volumes were examined and modeling strategies established. Second, a concurrent experimental investigation was undertaken to validate the stability of the seal at the equivalent operating conditions of the pump. Actual pump hardware was used to construct the test rig, also referred to as the (Flutter Rig). The flutter rig did not include rotational effects or temperature. However, the use of Hydrogen gas at high inlet pressure provided good representation of the critical parameters affecting flutter especially the speed of sound. The flutter code predictions showed consistent trends in good agreement with the experimental data. The rig test program produced a stability threshold empirical parameter that separated operation with and without flutter. This empirical parameter was used to establish the seal build clearances to avoid flutter while providing the required cooling flow metering. The calibrated flutter code along with the empirical flutter parameter was used to redesign the baseline seal resulting in a flutter-free robust configuration. Provisions for incorporation of mechanical damping devices were introduced in the redesigned seal to ensure added robustness

  15. Subsonic-transonic stall flutter study

    NASA Technical Reports Server (NTRS)

    Stardter, H.

    1979-01-01

    The objective of the Subsonic/Transonic Stall Flutter Program was to obtain detailed measurements of both the steady and unsteady flow field surrounding a rotor and the mechanical state of the rotor while it was operating in both steady and flutter modes to provide a basis for future analysis and for development of theories describing the flutter phenomenon. The program revealed that while all blades flutter at the same frequency, they do not flutter at the same amplitude, and their interblade phase angles are not equal. Such a pattern represents the superposition of a number of rotating nodal diameter patterns, each characterized by a different amplitude and different phase indexing, but each rotating at a speed that results in the same flutter frequency as seen in the rotor system. Review of the steady pressure contours indicated that flutter may alter the blade passage pressure distribution. The unsteady pressure amplitude contour maps reveal regions of high unsteady pressure amplitudes near the leading edge, lower amplitudes near the trailing.

  16. Unsteady Aerodynamic Model Tuning for Precise Flutter Prediction

    NASA Technical Reports Server (NTRS)

    Pak, Chan-Gi

    2011-01-01

    A simple method for an unsteady aerodynamic model tuning is proposed in this study. This method is based on the direct modification of the aerodynamic influence coefficient matrices. The aerostructures test wing 2 flight-test data is used to demonstrate the proposed model tuning method. The flutter speed margin computed using only the test validated structural dynamic model can be improved using the additional unsteady aerodynamic model tuning, and then the flutter speed margin requirement of 15 % in military specifications can apply towards the test validated aeroelastic model. In this study, unsteady aerodynamic model tunings are performed at two time invariant flight conditions, at Mach numbers of 0.390 and 0.456. When the Mach number for the unsteady model tuning approaches to the measured fluttering Mach number, 0.502, at the flight altitude of 9,837 ft, the estimated flutter speed is approached to the measured flutter speed at this altitude. The minimum flutter speed difference between the estimated and measured flutter speed is -.14 %.

  17. Unsteady Aerodynamic Model Tuning for Precise Flutter Prediction

    NASA Technical Reports Server (NTRS)

    Pak, Chan-gi

    2011-01-01

    A simple method for an unsteady aerodynamic model tuning is proposed in this study. This method is based on the direct modification of the aerodynamic influence coefficient matrices. The aerostructures test wing 2 flight-test data is used to demonstrate the proposed model tuning method. The flutter speed margin computed using only the test validated structural dynamic model can be improved using the additional unsteady aerodynamic model tuning, and then the flutter speed margin requirement of 15 percent in military specifications can apply towards the test validated aeroelastic model. In this study, unsteady aerodynamic model tunings are performed at two time invariant flight conditions, at Mach numbers of 0.390 and 0.456. When the Mach number for the unsteady aerodynamic model tuning approaches to the measured fluttering Mach number, 0.502, at the flight altitude of 9,837 ft, the estimated flutter speed is approached to the measured flutter speed at this altitude. The minimum flutter speed difference between the estimated and measured flutter speed is -0.14 percent.

  18. Transonic flutter study of a wind-tunnel model of a supercritical wing with/without winglet

    NASA Technical Reports Server (NTRS)

    Ruhlin, C. L.; Rauch, F. J., Jr.; Waters, C.

    1982-01-01

    The scaled flutter model was a 1/6.5-size, semispan version of a supercritical wing (SCW) proposed for an executive-jet-transport airplane. The model was tested cantilever-mounted with a normal wingtip, a wingtip with winglet, and a normal wingtip ballasted to simulate the winglet mass properties. Flutter and aerodynamic data were acquired at Mach numbers from 0.6 to 0.95. The measured transonic flutter speed boundary for each wingtip configuration had roughly the same shape with a minimum flutter speed near M = 0.82. The winglet addition and wingtip mass ballast decreased the wing flutter speed by about 7 and 5%, respectively; thus, the winglet effect on flutter was more a mass effect than an aerodynamic effect. Flutter characteristics calculated using a doublet-lattice analysis (which included interference effects) were in good agreement with the experimental results up to M = 0.82. Comparisons of measured static aerodynamic data with predicted data indicated that the model was aerodynamically representative of the airplane SCW.

  19. Retrospective analysis of reasons for failure of DDD pacemaker implantation in patients operated on between 1993 and 2005.

    PubMed

    Lelakowski, Jacek; Majewski, Jacek; Małecka, Barbara; Bednarek, Jacek; Stypuła, Paweł; Szeglowski, Marcin

    2007-01-01

    During implantation of a DDD pacemaker the following difficulties may be encountered: venous anomalies (the absence of vessels of adequate calibre or difficulty in subclavian vein puncture), arrhythmias during implantation (episodes of atrial flutter/fibrillation while the atrial leads are being positioned), lack of mechanical stability of the electrode in the heart chamber and inability to achieve an acceptable pacing and sensing threshold during implantation. The purpose of the study was to analyse retrospectively the reasons for DDD pacemaker failure in patients operated on between 1993 and 2005. We reviewed retrospectively all implantation data from 1988 to 2005 to identify patients with primary failure of DDD pacemaker implantation. Further analysis included patients who had received a DDD pacemaker between 1993 and 2005, when this type of pacemaker made up between 9 and 40% of all pacemaker implantations. We implanted 7469 pacemakers, including 1958 (26.2%) dual-chamber pacemakers, in 783 patients with atrioventricular block (AVB), 392 with sick sinus syndrome (SSS), 450 with AVB +/- SSS and 333 with tachy-brady syndrome (TBS). The mean age of the patients was 65.5 +/- 17.3 years. DDD pacing was unsuccessful in 108 (1.4%) patients, including 32 with AVB, 22 with SSS, 16 with SSS +/- AVB and 38 with TBS. The mean age of these patients was 78.5 +/- 19.4 years. The reasons for failed implantation were venous anomalies in 12%, an arrhythmia episode in 27.8%, a high pacing threshold in the atrium in 17.6%, low atrial potential amplitude in 25.9% and lack of mechanical stability of the electrode in 16.7% of patients. The difficulties were encountered in elderly patients (p < 0.01), most frequently in patients with SSS and TBS (71). Between 2004 and 2005 venous anomalies and a high pacing threshold were the main causes of failure. Currently the main difficulties encountered during pacemaker implantation are venous anomalies and a high pacing threshold. Arrhythmia episodes, low atrial potential amplitude and lack of mechanical stability are of minor importance. Elderly patients with sick sinus syndrome and tachy-brady syndrome have the highest failure rate. (Cardiol J 2007; 14: 155-159).

  20. Clinical outcomes in patients with atrial fibrillation according to sex during anticoagulation with apixaban or warfarin: a secondary analysis of a randomized controlled trial.

    PubMed

    Vinereanu, Dragos; Stevens, Susanna R; Alexander, John H; Al-Khatib, Sana M; Avezum, Alvaro; Bahit, Marıa Cecilia; Granger, Christopher B; Lopes, Renato D; Halvorsen, Sigrun; Hanna, Michael; Husted, Steen; Hylek, Elaine M; Mărgulescu, Andrei D; Wallentin, Lars; Atar, Dan

    2015-12-07

    To assess clinical outcomes, efficacy, and safety according to sex during anticoagulation with apixaban compared with warfarin in patients with atrial fibrillation. Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) was a randomized, double-blind, placebo-controlled, multicentre trial that included 11 785 (64.7%) men and 6416 (35.3%) women with atrial fibrillation or flutter randomized to receive either warfarin or apixaban. The primary efficacy endpoint was stroke or systemic embolism; secondary efficacy endpoints were death from any cause and cardiovascular death. The primary safety endpoint was major bleeding; secondary safety endpoints were a composite of major bleeding and non-major clinically relevant bleeding. The risk of stroke or systemic embolism was similar in women vs. men [adjusted hazard ratio (adjHR): 0.91; 95% confidence interval (CI): 0.74-1.12; P = 0.38]. However, among patients with history of stroke or transient ischaemic attack, women had a lower risk of recurrent stroke compared with men (adjHR: 0.70; 95% CI: 0.50-0.97; P = 0.036). Women also had a lower risk of all-cause death (adjHR: 0.63; 95% CI: 0.55-0.73; P < 0.0001) and cardiovascular death (adjHR: 0.62; 95% CI: 0.51-0.75; P < 0.0001), and a trend towards less major bleeding (adjHR: 0.86; 95% CI: 0.74-1.01; P = 0.066) and major or non-major clinically relevant bleeding (adjHR: 0.89; 95% CI: 0.80-1.00; P = 0.049). The efficacy and safety benefits of apixaban compared with warfarin were consistent regardless of sex. In the ARISTOTLE trial, women had a similar rate of stroke or systemic embolism but a lower risk of mortality and less clinically relevant bleeding than men. The efficacy and safety benefits of apixaban compared with warfarin were consistent in men and women. ARISTOTLE ClinicalTrials.gov number, NCT00412984. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  1. Large Scale Flutter Data for Design of Rotating Blades Using Navier-Stokes Equations

    NASA Technical Reports Server (NTRS)

    Guruswamy, Guru P.

    2012-01-01

    A procedure to compute flutter boundaries of rotating blades is presented; a) Navier-Stokes equations. b) Frequency domain method compatible with industry practice. Procedure is initially validated: a) Unsteady loads with flapping wing experiment. b) Flutter boundary with fixed wing experiment. Large scale flutter computation is demonstrated for rotating blade: a) Single job submission script. b) Flutter boundary in 24 hour wall clock time with 100 cores. c) Linearly scalable with number of cores. Tested with 1000 cores that produced data in 25 hrs for 10 flutter boundaries. Further wall-clock speed-up is possible by performing parallel computations within each case.

  2. Aircraft Flutter Testing

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Wilmer Reed gained international recognition for his innovative research, contributions and patented ideas relating to flutter and aeroelasticity of aerospace vehicles at Langley Research Center. In the early 1980's, Reed retired from Langley and joined the engineering staff of Dynamic Engineering Inc. While at DEI, Reed conceived and patented the DEI Flutter Exciter, now used world-wide in flight flutter testing of new or modified aircraft designs. When activated, the DEI Flutter Exciter alternately deflects the airstream upward and downward in a rapid manner, creating a force similar to that produced by an oscillating trailing edge flap. The DEI Flutter Exciter is readily adaptable to a variety of aircraft.

  3. Winglet effects on the flutter of twin-engine-transport type wing

    NASA Technical Reports Server (NTRS)

    Bhatia, K. G.; Nagaraja, K. S.; Ruhlin, C. L.

    1984-01-01

    Flutter characteristics of a cantilevered high aspect ratio wing with winglet were investigated. The configuration represented a current technology, twin-engine airplane. A low-speed and a high-speed model were used to evaluate compressibility effects through transonic Mach numbers and a wide range of mass-density ratios. Four flutter mechanisms were obtained in test, as well as analysis from various combinations of configuration parameters. The coupling between wing tip vertical and chordwise motions was shown to have significant effect under some conditions. It is concluded that, for the flutter model configurations studied, the winglet related flutter was amenable to the conventional flutter analysis techniques.

  4. Panel Flutter Emulation Using a Few Concentrated Forces

    NASA Astrophysics Data System (ADS)

    Dhital, Kailash; Han, Jae-Hung

    2018-04-01

    The objective of this paper is to study the feasibility of panel flutter emulation using a few concentrated forces. The concentrated forces are considered to be equivalent to aerodynamic forces. The equivalence is carried out using surface spline method and principle of virtual work. The structural modeling of the plate is based on the classical plate theory and the aerodynamic modeling is based on the piston theory. The present approach differs from the linear panel flutter analysis in scheming the modal aerodynamics forces with unchanged structural properties. The solutions for the flutter problem are obtained numerically using the standard eigenvalue procedure. A few concentrated forces were considered with an optimization effort to decide their optimal locations. The optimization process is based on minimizing the error between the flutter bounds from emulated and linear flutter analysis method. The emulated flutter results for the square plate of four different boundary conditions using six concentrated forces are obtained with minimal error to the reference value. The results demonstrated the workability and viability of using concentrated forces in emulating real panel flutter. In addition, the paper includes the parametric studies of linear panel flutter whose proper literatures are not available.

  5. Aeroelastic tailoring and structural optimization of joined-wing configurations

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Hwan

    2002-08-01

    Methodology for integrated aero-structural design was developed using formal optimization. ASTROS (Automated STRuctural Optimization System) was used as an analyzer and an optimizer for performing joined-wing weight optimization with stress, displacement, cantilever or body-freedom flutter constraints. As a pre/post processor, MATLAB was used for generating input file of ASTROS and for displaying the results of the ASTROS. The effects of the aeroelastic constraints on the isotropic and composite joined-wing weight were examined using this developed methodology. The aeroelastic features of a joined-wing aircraft were examined using both the Rayleigh-Ritz method and a finite element based aeroelastic stability and weight optimization procedure. Aircraft rigid-body modes are included to analyze of body-freedom flutter of the joined-wing aircraft. Several parametric studies were performed to determine the most important parameters that affect the aeroelastic behavior of a joined-wing aircraft. The special feature of a joined-wing aircraft is body-freedom flutter involving frequency interaction of the first elastic mode and the aircraft short period mode. In most parametric study cases, the body-freedom flutter speed was less than the cantilever flutter speed that is independent of fuselage inertia. As fuselage pitching moment of inertia was increased, the body-freedom flutter speed increased. When the pitching moment of inertia reaches a critical value, transition from body-freedom flutter to cantilever flutter occurred. The effects of composite laminate orientation on the front and rear wings of a joined-wing configuration were studied. An aircraft pitch divergence mode, which occurred because of forward movement of center of pressure due to wing deformation, was found. Body-freedom flutter and cantilever-like flutter were also found depending on combination of front and rear wing ply orientations. Optimized wing weight behaviors of the planar and non-planar configurations with isotropic and composite materials were investigated. Wing weight optimization of the composite joined-wing result in less weight compared to the metallic wing. Fuselage flexibility affects joined-wing flutter characteristics. Elastic mode shapes of the wing were affected by fuselage deformation and change the flutter speeds compared to the rigid fuselage. Body-freedom flutter speeds decrease as fuselage flexibility increases. Optimum wing weights increase as fuselage flexibility increases. Flutter analysis of a box wing configuration investigated the effects of center of gravity location and pitch moment of inertia on flutter speed.

  6. Supersonic Panel Flutter Test Results for Flat Fiber-Glass Sandwich Panels with Foamed Cores

    NASA Technical Reports Server (NTRS)

    Tuovila, W. J.; Presnell, John G., Jr.

    1961-01-01

    Flutter tests have been made on flat panels having a 1/4 inch-thick plastic-foam core covered with thin fiber-glass laminates. The testing was done in the Langley Unitary Plan wind tunnel at Mach numbers from 1.76 t o 2.87. The flutter boundary for these panels was found to be near the flutter boundary of thin metal panels when compared on the basis of an equivalent panel stiffness. The results also demonstrated that the depth of the cavity behind the panel has a pronounced influence on flutter. Changing the cavity depth from 1 1/2 inches to 1/2 inch reduced the dynamic pressure at start of flutter by 40 percent. No flutter was obtained when the spacers on the back of the panel were against the bottom of the cavity.

  7. Development and Flight Test of an Active Flutter Suppression System for the F-4F with Stores. Part I. Design of the Active Flutter Suppression System.

    DTIC Science & Technology

    1982-09-01

    of the wing-pylon-store changed considerably with excitation amplitude due to free play and preload. The active flutter suppression system worked well and provided an increase in flutter speed. (Author)

  8. Blade row interaction effects on flutter and forced response

    NASA Technical Reports Server (NTRS)

    Buffum, Daniel H.

    1993-01-01

    In the flutter or forced response analysis of a turbomachine blade row, the blade row in question is commonly treated as if it is isolated from the neigboring blade rows. Disturbances created by vibrating blades are then free to propagate away from this blade row without being disturbed. In reality, neighboring blade rows will reflect some portion of this wave energy back toward the vibrating blades, causing additional unsteady forces on them. It is of fundamental importance to determine whether or not these reflected waves can have a significant effect on the aeroelastic stability or forced response of a blade row. Therefore, a procedure to calculate intra-blade-row unsteady aerodynamic interactions was developed which relies upon results available from isolated blade row unsteady aerodynamic analyses. In addition, an unsteady aerodynamic influence coefficient technique is used to obtain a model for the vibratory response in which the neighboring blade rows are also flexible. The flutter analysis shows that interaction effects can be destabilizing, and the forced response analysis shows that interaction effects can result in a significant increase in the resonant response of a blade row.

  9. Flutter parametric studies of cantilevered twin-engine-transport type wing with and without winglet. Volume 1: Low-speed investigations

    NASA Technical Reports Server (NTRS)

    Bhatia, K. G.; Nagaraja, K. S.

    1984-01-01

    Flutter characteristics of a cantilevered high aspect ratio wing with winglet were investigated. The configuration represented a current technology, twin-engine airplane. A low-speed and high-speed model were used to evaluate compressibility effects through transonic Mach numbers and a wide range of mass-density ratios. Four flutter mechanisms were obtained in test, as well as analysis from various combinations of configuration parameters. The coupling between wing tip vertical and chordwise motions was shown to have significant effect under some conditions. It is concluded that for the flutter model configurations studied, the winglet related flutter was amenable to the conventional flutter analysis techniques.

  10. Half Wing N219 Aircraft Model Clean Configuration for Flutter Test On Low Speed Wind Tunnel

    NASA Astrophysics Data System (ADS)

    Syamsuar, Sayuti; Sampurno, Budi; Mayang Mahasti, Katia; Bayu Sakti Pratama, Muchamad; Widi Sasongko, Triyono; Kartika, Nina; Suksmono, Adityo; Aji Saputro, Mohamad Ivan; Bahtera Eskayudha, Dimas

    2018-04-01

    Flutter is a rapid self-feeding motion which is caused by the interaction of aerodynamic, structural and inertial forces. Flutter can cause major damage on aircraft structure which can lead to fatal accident in aviation. Several methods have been evolved to avoid the flutter phenomena occur during the flight envelope of aircraft design. On this study, method was developed by Indonesian Aerospace which consist of Finite Element Method (FEM) analysis, Ground Vibration Test (GVT), and Wind Tunnel Flutter Test (WTT). Based on the study, FEM have similar results toward to Wind Tunnel Flutter Test conjunction the clean configuration of N219 aircraft half wing model.

  11. Maximum voltage gradient technique for optimization of ablation for typical atrial flutter with zero-fluoroscopy approach

    PubMed Central

    Deutsch, Karol; Śledź, Janusz; Mazij, Mariusz; Ludwik, Bartosz; Labus, Michał; Karbarz, Dariusz; Pasicka, Bernadetta; Chrabąszcz, Michał; Śledź, Arkadiusz; Klank-Szafran, Monika; Vitali-Sendoz, Laura; Kameczura, Tomasz; Śpikowski, Jerzy; Stec, Piotr; Ujda, Marek; Stec, Sebastian

    2017-01-01

    Abstract Radiofrequency catheter ablation (RFCA) is an established effective method for the treatment of typical cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). The introduction of 3-dimensional electro-anatomic systems enables RFCA without fluoroscopy (No-X-Ray [NXR]). The aim of this study was to evaluate the feasibility and effectiveness of CTI RFCA during implementation of the NXR approach and the maximum voltage-guided (MVG) technique for ablation of AFL. Data were obtained from prospective standardized multicenter ablation registry. Consecutive patients with the first RFCA for CTI-dependent AFL were recruited. Two navigation approaches (NXR and fluoroscopy based as low as reasonable achievable [ALARA]) and 2 mapping and ablation techniques (MVG and pull-back technique [PBT]) were assessed. NXR + MVG (n  =  164; age: 63.7 ± 9.5; 30% women), NXR + PBT (n  =  55; age: 63.9 ± 10.7; 39% women); ALARA + MVG (n  =  36; age: 64.2 ± 9.6; 39% women); and ALARA + PBT (n  =  205; age: 64.7 ± 9.1; 30% women) were compared, respectively. All groups were simplified with a 2-catheter femoral approach using 8-mm gold tip catheters (Osypka AG, Germany or Biotronik, Germany) with 15 min of observation. The MVG technique was performed using step-by-step application by mapping the largest atrial signals within the CTI. Bidirectional block in CTI was achieved in 99% of all patients (P  =  NS, between groups). In NXR + MVG and NXR + PBT groups, the procedure time decreased (45.4 ± 17.6 and 47.2 ± 15.7 min vs. 52.6 ± 23.7 and 59.8 ± 24.0 min, P < .01) as compared to ALARA + MVG and ALARA + PBT subgroups. In NXR + MVG and NXR + PBT groups, 91% and 98% of the procedures were performed with complete elimination of fluoroscopy. The NXR approach was associated with a significant reduction in fluoroscopy exposure (from 0.2 ± 1.1 [NXR + PBT] and 0.3 ± 1.6 [NXR + MVG] to 7.7 ± 6.0 min [ALARA + MVG] and 9.1 ± 7.2 min [ALARA + PBT], P < .001). The total application time significantly decreased in the MVG technique subgroup both in NXR and ALARA (P < .01). No major complications were observed in either groups. Complete elimination of fluoroscopy is feasible, safe, and effective during RFCA of CTI in almost all AFL patients without cardiac implanted electronic devices. The most optimal method for RFCA of CTI-dependent AFL seems to be MVG; however, it required validation of optimal RFCA's parameters with clinical follow-up. PMID:28640075

  12. Maximum voltage gradient technique for optimization of ablation for typical atrial flutter with zero-fluoroscopy approach.

    PubMed

    Deutsch, Karol; Śledź, Janusz; Mazij, Mariusz; Ludwik, Bartosz; Labus, Michał; Karbarz, Dariusz; Pasicka, Bernadetta; Chrabąszcz, Michał; Śledź, Arkadiusz; Klank-Szafran, Monika; Vitali-Sendoz, Laura; Kameczura, Tomasz; Śpikowski, Jerzy; Stec, Piotr; Ujda, Marek; Stec, Sebastian

    2017-06-01

    Radiofrequency catheter ablation (RFCA) is an established effective method for the treatment of typical cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). The introduction of 3-dimensional electro-anatomic systems enables RFCA without fluoroscopy (No-X-Ray [NXR]). The aim of this study was to evaluate the feasibility and effectiveness of CTI RFCA during implementation of the NXR approach and the maximum voltage-guided (MVG) technique for ablation of AFL.Data were obtained from prospective standardized multicenter ablation registry. Consecutive patients with the first RFCA for CTI-dependent AFL were recruited. Two navigation approaches (NXR and fluoroscopy based as low as reasonable achievable [ALARA]) and 2 mapping and ablation techniques (MVG and pull-back technique [PBT]) were assessed. NXR + MVG (n  =  164; age: 63.7 ± 9.5; 30% women), NXR + PBT (n  =  55; age: 63.9 ± 10.7; 39% women); ALARA + MVG (n  =  36; age: 64.2 ± 9.6; 39% women); and ALARA + PBT (n  =  205; age: 64.7 ± 9.1; 30% women) were compared, respectively. All groups were simplified with a 2-catheter femoral approach using 8-mm gold tip catheters (Osypka AG, Germany or Biotronik, Germany) with 15 min of observation. The MVG technique was performed using step-by-step application by mapping the largest atrial signals within the CTI.Bidirectional block in CTI was achieved in 99% of all patients (P  =  NS, between groups). In NXR + MVG and NXR + PBT groups, the procedure time decreased (45.4 ± 17.6 and 47.2 ± 15.7 min vs. 52.6 ± 23.7 and 59.8 ± 24.0 min, P < .01) as compared to ALARA + MVG and ALARA + PBT subgroups. In NXR + MVG and NXR + PBT groups, 91% and 98% of the procedures were performed with complete elimination of fluoroscopy. The NXR approach was associated with a significant reduction in fluoroscopy exposure (from 0.2 ± 1.1 [NXR + PBT] and 0.3 ± 1.6 [NXR + MVG] to 7.7 ± 6.0 min [ALARA + MVG] and 9.1 ± 7.2 min [ALARA + PBT], P < .001). The total application time significantly decreased in the MVG technique subgroup both in NXR and ALARA (P < .01). No major complications were observed in either groups.Complete elimination of fluoroscopy is feasible, safe, and effective during RFCA of CTI in almost all AFL patients without cardiac implanted electronic devices. The most optimal method for RFCA of CTI-dependent AFL seems to be MVG; however, it required validation of optimal RFCA's parameters with clinical follow-up.

  13. Experimental Investigation of a Preloaded Spring-tab Flutter Model

    NASA Technical Reports Server (NTRS)

    Smith, N H; Clevenson, S A; Barmby, J G

    1947-01-01

    An experimental investigation was made of a preloaded spring-tab flutter model to determine the effects on flutter speed of aspect ratio, tab frequency, and preloaded spring constant. The rudder was mass-balanced, and the flutter mode studied was essentially one of three degrees of freedom (fin bending coupled with rudder and tab oscillations). Inasmuch as the spring was preloaded, the tab-spring system was a nonlinear one. Frequency of the tab was the most significant parameter in this study, and an increase in flutter speed with increasing frequency is indicated. At a given frequency, the tab of high aspect ratio is shown to have a slightly lower flutter speed than the one of low aspect ratio. Because the frequency of the preloaded spring tab was found to vary radically with amplitude, the flutter speed decreased with increase in initial displacement of the tab.

  14. Developing, mechanizing and testing of a digital active flutter suppression system for a modified B-52 wind-tunnel model

    NASA Technical Reports Server (NTRS)

    Matthew, J. R.

    1980-01-01

    A digital flutter suppression system was developed and mechanized for a significantly modified version of the 1/30-scale B-52E aeroelastic wind tunnel model. A model configuration was identified that produced symmetric and antisymmetric flutter modes that occur at 2873N/sq m (60 psf) dynamic pressure with violent onset. The flutter suppression system, using one trailing edge control surface and the accelerometers on each wing, extended the flutter dynamic pressure of the model beyond the design limit of 4788N/sq m (100 psf). The hardware and software required to implement the flutter suppression system were designed and mechanized using digital computers in a fail-operate configuration. The model equipped with the system was tested in the Transonic Dynamics Tunnel at NASA Langley Research Center and results showed the flutter dynamic pressure of the model was extended beyond 4884N/sq m (102 psf).

  15. Panel-flutter analysis of a thermal protection-shield concept for the space shuttle.

    NASA Technical Reports Server (NTRS)

    Cunningham, H. J.

    1972-01-01

    Analysis of the panel flutter characteristics of a candidate thermal protection system (TPS) for the space shuttle, using piston theory aerodynamics and Lagrange equations. The results show the TPS candidate panel array to be deep in the 'no-flutter' region during launch and, therefore, safe from panel flutter.

  16. Development and Flight Test of an Active Flutter Suppression System for the F-4F with Stores. Part 3. Flight Demonstration of the Active Flutter Suppression System.

    DTIC Science & Technology

    1983-06-01

    that the dynamic behavior of the wing-pylon-store changed considerably with excitation amplitude due to free play and preload. The active flutter suppression system worked well and provided an increase in flutter speed.

  17. An experimental and analytical investigation of proprotor whirl flutter

    NASA Technical Reports Server (NTRS)

    Kvaternik, R. G.; Kohn, J. S.

    1977-01-01

    The results of an experimental parametric investigation of whirl flutter are presented for a model consisting of a windmilling propeller-rotor, or proprotor, having blades with offset flapping hinges mounted on a rigid pylon with flexibility in pitch and yaw. The investigation was motivated by the need to establish a large data base from which to assess the predictability of whirl flutter for a proprotor since some question has been raised as to whether flutter in the forward whirl mode could be predicted with confidence. To provide the necessary data base, the parametric study included variation in the pylon pitch and yaw stiffnesses, flapping hinge offset, and blade kinematic pitch-flap coupling over a large range of advance ratios. Cases of forward whirl flutter and of backward whirl flutter are documented. Measured whirl flutter characteristics were shown to be in good agreement with predictions from two different linear stability analyses which employed simple, two dimensional, quasi-steady aerodynamics for the blade loading. On the basis of these results, it appears that proprotor whirl flutter, both forward and backward, can be predicted.

  18. Effects of winglet on transonic flutter characteristics of a cantilevered twin-engine-transport wing model

    NASA Technical Reports Server (NTRS)

    Ruhlin, C. L.; Bhatia, K. G.; Nagaraja, K. S.

    1986-01-01

    A transonic model and a low-speed model were flutter tested in the Langley Transonic Dynamics Tunnel at Mach numbers up to 0.90. Transonic flutter boundaries were measured for 10 different model configurations, which included variations in wing fuel, nacelle pylon stiffness, and wingtip configuration. The winglet effects were evaluated by testing the transonic model, having a specific wing fuel and nacelle pylon stiffness, with each of three wingtips, a nonimal tip, a winglet, and a nominal tip ballasted to simulate the winglet mass. The addition of the winglet substantially reduced the flutter speed of the wing at transonic Mach numbers. The winglet effect was configuration-dependent and was primarily due to winglet aerodynamics rather than mass. Flutter analyses using modified strip-theory aerodynamics (experimentally weighted) correlated reasonably well with test results. The four transonic flutter mechanisms predicted by analysis were obtained experimentally. The analysis satisfactorily predicted the mass-density-ratio effects on subsonic flutter obtained using the low-speed model. Additional analyses were made to determine the flutter sensitivity to several parameters at transonic speeds.

  19. Flutter Phenomenon in Flow Driven Energy Harvester–A Unified Theoretical Model for “Stiff” and “Flexible” Materials

    PubMed Central

    Chen, Yu; Mu, Xiaojing; Wang, Tao; Ren, Weiwei; Yang, Ya; Wang, Zhong Lin; Sun, Chengliang; Gu, Alex Yuandong

    2016-01-01

    Here, we report a stable and predictable aero-elastic motion in the flow-driven energy harvester, which is different from flapping and vortex-induced-vibration (VIV). A unified theoretical frame work that describes the flutter phenomenon observed in both “stiff” and “flexible” materials for flow driven energy harvester was presented in this work. We prove flutter in both types of materials is the results of the coupled effects of torsional and bending modes. Compared to “stiff” materials, which has a flow velocity-independent flutter frequency, flexible material presents a flutter frequency that almost linearly scales with the flow velocity. Specific to “flexible” materials, pre-stress modulates the frequency range in which flutter occurs. It is experimentally observed that a double-clamped “flexible” piezoelectric P(VDF-TrFE) thin belt, when driven into the flutter state, yields a 1,000 times increase in the output voltage compared to that of the non-fluttered state. At a fixed flow velocity, increase in pre-stress level of the P(VDF-TrFE) thin belt up-shifts the flutter frequency. In addition, this work allows the rational design of flexible piezoelectric devices, including flow-driven energy harvester, triboelectric energy harvester, and self-powered wireless flow speed sensor. PMID:27739484

  20. Flutter Phenomenon in Flow Driven Energy Harvester-A Unified Theoretical Model for "Stiff" and "Flexible" Materials.

    PubMed

    Chen, Yu; Mu, Xiaojing; Wang, Tao; Ren, Weiwei; Yang, Ya; Wang, Zhong Lin; Sun, Chengliang; Gu, Alex Yuandong

    2016-10-14

    Here, we report a stable and predictable aero-elastic motion in the flow-driven energy harvester, which is different from flapping and vortex-induced-vibration (VIV). A unified theoretical frame work that describes the flutter phenomenon observed in both "stiff" and "flexible" materials for flow driven energy harvester was presented in this work. We prove flutter in both types of materials is the results of the coupled effects of torsional and bending modes. Compared to "stiff" materials, which has a flow velocity-independent flutter frequency, flexible material presents a flutter frequency that almost linearly scales with the flow velocity. Specific to "flexible" materials, pre-stress modulates the frequency range in which flutter occurs. It is experimentally observed that a double-clamped "flexible" piezoelectric P(VDF-TrFE) thin belt, when driven into the flutter state, yields a 1,000 times increase in the output voltage compared to that of the non-fluttered state. At a fixed flow velocity, increase in pre-stress level of the P(VDF-TrFE) thin belt up-shifts the flutter frequency. In addition, this work allows the rational design of flexible piezoelectric devices, including flow-driven energy harvester, triboelectric energy harvester, and self-powered wireless flow speed sensor.

  1. Wind Tunnel Measurements for Flutter of a Long-Afterbody Bridge Deck

    PubMed Central

    Chen, Zeng-Shun; Zhang, Cheng; Wang, Xu; Ma, Cun-Ming

    2017-01-01

    Bridges are an important component of transportation. Flutter is a self-excited, large amplitude vibration, which may lead to collapse of bridges. It must be understood and avoided. This paper takes the Jianghai Channel Bridge, which is a significant part of the Hong Kong-Zhuhai-Macao Bridge, as an example to investigate the flutter of the bridge deck. Firstly, aerodynamic force models for flutter of bridges were introduced. Then, wind tunnel tests of the bridge deck during the construction and the operation stages, under different wind attack angles and wind velocities, were carried out using a high frequency base balance (HFBB) system and laser displacement sensors. From the tests, the static aerodynamic forces and flutter derivatives of the bridge deck were observed. Correspondingly, the critical flutter wind speeds of the bridge deck were determined based on the derivatives, and they are compared with the directly measured flutter speeds. Results show that the observed derivatives are reasonable and applicable. Furthermore, the critical wind speeds in the operation stage is smaller than those in the construction stage. Besides, the flutter instabilities of the bridge in the construction and the operation stages are good. This study helps guarantee the design and the construction of the Jianghai Channel Bridge, and advances the understanding of flutter of long afterbody bridge decks. PMID:28208773

  2. Wind Tunnel Measurements for Flutter of a Long-Afterbody Bridge Deck.

    PubMed

    Chen, Zeng-Shun; Zhang, Cheng; Wang, Xu; Ma, Cun-Ming

    2017-02-09

    Bridges are an important component of transportation. Flutter is a self-excited, large amplitude vibration, which may lead to collapse of bridges. It must be understood and avoided. This paper takes the Jianghai Channel Bridge, which is a significant part of the Hong Kong-Zhuhai-Macao Bridge, as an example to investigate the flutter of the bridge deck. Firstly, aerodynamic force models for flutter of bridges were introduced. Then, wind tunnel tests of the bridge deck during the construction and the operation stages, under different wind attack angles and wind velocities, were carried out using a high frequency base balance (HFBB) system and laser displacement sensors. From the tests, the static aerodynamic forces and flutter derivatives of the bridge deck were observed. Correspondingly, the critical flutter wind speeds of the bridge deck were determined based on the derivatives, and they are compared with the directly measured flutter speeds. Results show that the observed derivatives are reasonable and applicable. Furthermore, the critical wind speeds in the operation stage is smaller than those in the construction stage. Besides, the flutter instabilities of the bridge in the construction and the operation stages are good. This study helps guarantee the design and the construction of the Jianghai Channel Bridge, and advances the understanding of flutter of long afterbody bridge decks.

  3. Flutter Boundary Identification From Simulation Time Histories

    NASA Technical Reports Server (NTRS)

    Baker, Myles; Goggin, P. J.

    1997-01-01

    While there has been much recent progress in simulating nonlinear aeroelastic systems, and in predicting many of the aeroelastic phenomena of concern in transport aircraft design (i.e. transonic flutter buckets), the utility of a simulation in generating an understanding of the flutter behavior is limited. This is due in part to the high cost of generating these simulations; and the implied limitation on the number of conditions that can be analyzed, but there are also some difficulties introduced by the very nature of a simulation. Flutter engineers have traditionally worked in the frequency domain, and are accustomed to describing the flutter behavior of an airplane in terms of its V-G and V-F (or Q-G and Q-F) plots and flutter mode shapes. While the V-G and V-F plots give information about how the dynamic response of an airplane changes as the airspeed is increased, the simulation only gives information about one isolated condition (Mach, airspeed, altitude, etc.). Therefore, where a traditional flutter analysis can let the engineer determine an airspeed at which an airplane becomes unstable, while a simulation only serves as a binary check: either the airplane is fluttering at this condition, or it is not. In this document, a new technique is described in which system identification is used to easily extract modal frequencies and damping ratios from simulation time histories, and shows how the identified parameters can be used to determine the variation in frequency and dampin,o ratio as the airspeed is changed. This technique not only provides the flutter engineer with added insight into the aeroelastic behavior of the airplane, but it allows calculation of flutter mode shapes, and allows estimation of flutter boundaries while minimizing the number of simulations required.

  4. Magnetic resonance imaging-compatible circular mapping catheter: an in vivo feasibility and safety study.

    PubMed

    Elbes, Delphine; Magat, Julie; Govari, Assaf; Ephrath, Yaron; Vieillot, Delphine; Beeckler, Christopher; Weerasooriya, Rukshen; Jais, Pierre; Quesson, Bruno

    2017-03-01

    Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. Embolic risk in atrial fibrillation that arises from hyperthyroidism: review of the medical literature.

    PubMed

    Traube, Elie; Coplan, Neil L

    2011-01-01

    Atrial fibrillation, the most common cardiac complication of hyperthyroidism, occurs in an estimated 10% to 25% of overtly hyperthyroid patients. The prevalence of atrial fibrillation increases with age in the general population and in thyrotoxic patients. Other risk factors for atrial fibrillation in thyrotoxic patients include male sex, ischemic or valvular heart disease, and congestive heart failure. The incidence of arterial embolism or stroke in thyrotoxic atrial fibrillation is less clear. There are many reports of arterial thromboembolism associated with hyperthyroidism, including cases of young adults without coexisting risk factors other than thyrotoxic atrial fibrillation. The use of anticoagulative agents to prevent thromboembolic sequelae of thyrotoxic atrial fibrillation is controversial: National organizations provide conflicting recommendations in their practice guidelines. Herein, we review the medical literature and examine the evidence behind the recommendations in order to determine the best approach to thromboembolic prophylaxis in patients who have atrial fibrillation that is associated with hyperthyroidism.

  6. Embolic Risk in Atrial Fibrillation that Arises from Hyperthyroidism

    PubMed Central

    Traube, Elie; Coplan, Neil L.

    2011-01-01

    Atrial fibrillation, the most common cardiac complication of hyperthyroidism, occurs in an estimated 10% to 25% of overtly hyperthyroid patients. The prevalence of atrial fibrillation increases with age in the general population and in thyrotoxic patients. Other risk factors for atrial fibrillation in thyrotoxic patients include male sex, ischemic or valvular heart disease, and congestive heart failure. The incidence of arterial embolism or stroke in thyrotoxic atrial fibrillation is less clear. There are many reports of arterial thromboembolism associated with hyperthyroidism, including cases of young adults without coexisting risk factors other than thyrotoxic atrial fibrillation. The use of anticoagulative agents to prevent thromboembolic sequelae of thyrotoxic atrial fibrillation is controversial: national organizations provide conflicting recommendations in their practice guidelines. Herein, we review the medical literature and examine the evidence behind the recommendations in order to determine the best approach to thromboembolic prophylaxis in patients who have atrial fibrillation that is associated with hyperthyroidism. PMID:21720457

  7. A wind-tunnel investigation of a B-52 model flutter suppression system

    NASA Technical Reports Server (NTRS)

    Redd, L. T.; Gilman, J., Jr.; Cooley, D. E.; Sevart, F. D.

    1974-01-01

    Flutter modeling techniques have been successfully extended to the difficult case of the active suppression of flutter. The demonstration was conducted in a transonic dynamics tunnel using a 1/30 scale, elastic, dynamic model of a Boeing B-52 control configured vehicle. The results from the study show that with the flutter suppression system operating there is a substantial increase in the damping associated with the critical flutter mode. The results also show good correlation between the damping characteristics of the model and the aircraft.

  8. A computer program for automated flutter solution and matched point determination

    NASA Technical Reports Server (NTRS)

    Bhatia, K. G.

    1973-01-01

    The use of a digital computer program (MATCH) for automated determination of the flutter velocity and the matched-point flutter density is described. The program is based on the use of the modified Laguerre iteration formula to converge to a flutter crossing or a matched-point density. A general description of the computer program is included and the purpose of all subroutines used is stated. The input required by the program and various input options are detailed, and the output description is presented. The program can solve flutter equations formulated with up to 12 vibration modes and obtain flutter solutions for up to 10 air densities. The program usage is illustrated by a sample run, and the FORTRAN program listing is included.

  9. Supersonic unstalled flutter. [aerodynamic loading of thin airfoils induced by cascade motion

    NASA Technical Reports Server (NTRS)

    Adamczyk, J. J.; Goldstein, M. E.; Hartmann, M. J.

    1978-01-01

    Flutter analyses were developed to predict the onset of supersonic unstalled flutter of a cascade of two-dimensional airfoils. The first of these analyzes the onset of supersonic flutter at low levels of aerodynamic loading (i.e., backpressure), while the second examines the occurrence of supersonic flutter at moderate levels of aerodynamic loading. Both of these analyses are based on the linearized unsteady inviscid equations of gas dynamics to model the flow field surrounding the cascade. These analyses are utilized in a parametric study to show the effects of cascade geometry, inlet Mach number, and backpressure on the onset of single and multi degree of freedom unstalled supersonic flutter. Several of the results are correlated against experimental qualitative observation to validate the models.

  10. Arrhythmias in Patients with Atrial Defects.

    PubMed

    Contractor, Tahmeed; Mandapati, Ravi

    2017-06-01

    Atrial arrhythmias are common in patients with atrial septal defects. A myriad of factors are responsible for these that include remodeling related to the defect and scar created by the repair or closure. An understanding of potential arrhythmias, along with entrainment and high-density activation mapping can result in accurate diagnosis and successful ablation. Atrial fibrillation is being seen increasingly after patent foramen ovale closure and may be the primary etiology of recurrent stroke in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. The development of the DAST I remotely piloted research vehicle for flight testing an active flutter suppression control system. Ph.D. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Grose, D. L.

    1979-01-01

    The development of the DAST I (drones for aerodynamic and structural testing) remotely piloted research vehicle is described. The DAST I is a highly modified BQM-34E/F Firebee II Supersonic Aerial Target incorporating a swept supercritical wing designed to flutter within the vehicle's flight envelope. The predicted flutter and rigid body characteristics are presented. A description of the analysis and design of an active flutter suppression control system (FSS) designed to increase the flutter boundary of the DAST wing (ARW-1) by a factor of 20% is given. The design and development of the digital remotely augmented primary flight control system and on-board analog backup control system is presented. An evaluation of the near real-time flight flutter testing methods is made by comparing results of five flutter testing techniques on simulated DAST I flutter data. The development of the DAST ARW-1 state variable model used to generate time histories of simulated accelerometer responses is presented. This model uses control surface commands and a Dryden model gust as inputs. The feasibility of the concept of extracting open loop flutter characteristics from closed loop FSS responses was examined. It was shown that open loop characteristics can be determined very well from closed loop subcritical responses.

  12. Flight flutter testing of multi-jet aircraft

    NASA Technical Reports Server (NTRS)

    Bartley, J.

    1975-01-01

    Extensive flight flutter tests were conducted by BAC on B-52 and KC-135 prototype airplanes. The need for and importance of these flight flutter programs to Boeing airplane design are discussed. Basic concepts of flight flutter testing of multi-jet aircraft and analysis of the test data will be presented. Exciter equipment and instrumentation employed in these tests will be discussed.

  13. Experimental and analytical transonic flutter characteristics of a geared-elevator configuration

    NASA Technical Reports Server (NTRS)

    Ruhlin, C. L.; Doggett, R. V., Jr.; Gregory, R. A.

    1980-01-01

    The flutter model represented the aft fuselage and empennage of a proposed supersonic transport airplane and had an all movable horizontal tail with a geared elevator. It was tested mounted from a sting in the transonic dynamics tunnel. Symmetric flutter boundaries were determined experimentally at Mach numbers from 0.7 to 1.14 for a geared elevator configuration (gear ratio of 2.8 to 1.0) and an ungeared elevator configuration (gear ratio of 1.0 to 1.0). Gearing the elevator increased the experimental flutter dynamic pressures about 20 percent. Flutter calculations were made for the geared elevator configuration by using two analytical methods based on subsonic lifting surface theory. Both methods analyzed the stabilizer and elevator as a single, deforming surface, but one method also allowed the elevator to be analyzed as hinged from the stabilizer. All analyses predicted lower flutter dynamic pressures than experiment with best agreement (within 12 percent) for the hinged elevator method. Considering the model as mounted from a flexible rather than rigid sting in the analyses, had only a slight effect on the flutter results but was significant in that a sting related vibration mode was identified as a potentially flutter critical mode.

  14. Flutter analysis of swept-wing subsonic aircraft with parameter studies of composite wings

    NASA Technical Reports Server (NTRS)

    Housner, J. M.; Stein, M.

    1974-01-01

    A computer program is presented for the flutter analysis, including the effects of rigid-body roll, pitch, and plunge of swept-wing subsonic aircraft with a flexible fuselage and engines mounted on flexible pylons. The program utilizes a direct flutter solution in which the flutter determinant is derived by using finite differences, and the root locus branches of the determinant are searched for the lowest flutter speed. In addition, a preprocessing subroutine is included which evaluates the variable bending and twisting stiffness properties of the wing by using a laminated, balanced ply, filamentary composite plate theory. The program has been substantiated by comparisons with existing flutter solutions. The program has been applied to parameter studies which examine the effect of filament orientation upon the flutter behavior of wings belonging to the following three classes: wings having different angles of sweep, wings having different mass ratios, and wings having variable skin thicknesses. These studies demonstrated that the program can perform a complete parameter study in one computer run. The program is designed to detect abrupt changes in the lowest flutter speed and mode shape as the parameters are varied.

  15. Interactive flutter analysis and parametric study for conceptual wing design

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1995-01-01

    An interactive computer program was developed for wing flutter analysis in the conceptual design stage. The objective was to estimate the flutter instability boundary of a flexible cantilever wing, when well defined structural and aerodynamic data are not available, and then study the effect of change in Mach number, dynamic pressure, torsional frequency, sweep, mass ratio, aspect ratio, taper ratio, center of gravity, and pitch inertia, to guide the development of the concept. The software was developed on MathCad (trademark) platform for Macintosh, with integrated documentation, graphics, database and symbolic mathematics. The analysis method was based on nondimensional parametric plots of two primary flutter parameters, namely Regier number and Flutter number, with normalization factors based on torsional stiffness, sweep, mass ratio, aspect ratio, center of gravity location and pitch inertia radius of gyration. The plots were compiled in a Vaught Corporation report from a vast database of past experiments and wind tunnel tests. The computer program was utilized for flutter analysis of the outer wing of a Blended Wing Body concept, proposed by McDonnell Douglas Corporation. Using a set of assumed data, preliminary flutter boundary and flutter dynamic pressure variation with altitude, Mach number and torsional stiffness were determined.

  16. Auditory fovea and Doppler shift compensation: adaptations for flutter detection in echolocating bats using CF-FM signals.

    PubMed

    Schnitzler, Hans-Ulrich; Denzinger, Annette

    2011-05-01

    Rhythmical modulations in insect echoes caused by the moving wings of fluttering insects are behaviourally relevant information for bats emitting CF-FM signals with a high duty cycle. Transmitter and receiver of the echolocation system in flutter detecting foragers are especially adapted for the processing of flutter information. The adaptations of the transmitter are indicated by a flutter induced increase in duty cycle, and by Doppler shift compensation (DSC) that keeps the carrier frequency of the insect echoes near a reference frequency. An adaptation of the receiver is the auditory fovea on the basilar membrane, a highly expanded frequency representation centred to the reference frequency. The afferent projections from the fovea lead to foveal areas with an overrepresentation of sharply tuned neurons with best frequencies near the reference frequency throughout the entire auditory pathway. These foveal neurons are very sensitive to stimuli with natural and simulated flutter information. The frequency range of the foveal areas with their flutter processing neurons overlaps exactly with the frequency range where DS compensating bats most likely receive echoes from fluttering insects. This tight match indicates that auditory fovea and DSC are adaptations for the detection and evaluation of insects flying in clutter.

  17. Anemia: An Independent Predictor Of Adverse Outcomes In Older Patients With Atrial Fibrillation.

    PubMed

    Ali, Ali N; Athavale, Nandkishor V; Abdelhafiz, Ahmed H

    2016-01-01

    Both anemia and atrial fibrillation are common in older people and their prevalence is age dependent which increases as population ages. Anemia, especially acute onset, predisposes to new onset atrial fibrillation which is likely to be mediated through inducing heart failure first and this predisposition seems to be potentiated by the presence of renal impairment. Anemia adds to the comorbidity burden of patients with atrial fibrillation and independently increases the risks of adverse outcomes such as increased hospitalization, mortality, bleeding and thromboembolic events. Early detection and correction of anemia in patients with atrial fibrillation may have a positive impact on reducing these adverse events.

  18. Computational Modeling and Analysis of Aeroelastic Wing Flutter

    NASA Astrophysics Data System (ADS)

    Menon, Karthik; Katz, Joseph; Mittal, Rajat

    2017-11-01

    Aeroelastic flutter is ubiquitous in aeronautics; of particular relevance here is the flutter of aircraft wings, helicopter rotor blades, flexible wing MAVs and UAVs, and long-endurance aerial systems such as airships and solar powered air-vehicles. Here, we attempt to understand some fundamental aspects of this problem via immersed boundary method based numerical simulations of canonical bodies. We report findings on the effect of body geometry on the dynamics of flutter involving coupled pitch-heave oscillations. We also explore flow-induced flutter of airfoils in pre and post-stall configurations, including the effect of stiffness and pitch axis location. Finally, a novel force decomposition method is used to provide some insight into the flutter dynamics and associated unsteady flow physics. This work is supported by AFOSR Grant FA9550-16-1-0404.

  19. Supersonic cruise research aircraft structural studies: Methods and results

    NASA Technical Reports Server (NTRS)

    Sobieszczanski-Sobieski, J.; Gross, D.; Kurtze, W.; Newsom, J.; Wrenn, G.; Greene, W.

    1981-01-01

    NASA Langley Research Center SCAR in-house structural studies are reviewed. In methods development, advances include a new system of integrated computer programs called ISSYS, progress in determining aerodynamic loads and aerodynamically induced structural loads (including those due to gusts), flutter optimization for composite and metal airframe configurations using refined and simplified mathematical models, and synthesis of active controls. Results given address several aspects of various SCR configurations. These results include flutter penalties on composite wing, flutter suppression using active controls, roll control effectiveness, wing tip ground clearance, tail size effect on flutter, engine weight and mass distribution influence on flutter, and strength and flutter optimization of new configurations. The ISSYS system of integrated programs performed well in all the applications illustrated by the results, the diversity of which attests to ISSYS' versatility.

  20. Flutter Sensitivity to Boundary Layer Thickness, Structural Damping, and Static Pressure Differential for a Shuttle Tile Overlay Repair Concept

    NASA Technical Reports Server (NTRS)

    Scott, Robert C.; Bartels, Robert E.

    2009-01-01

    This paper examines the aeroelastic stability of an on-orbit installable Space Shuttle patch panel. CFD flutter solutions were obtained for thick and thin boundary layers at a free stream Mach number of 2.0 and several Mach numbers near sonic speed. The effect of structural damping on these flutter solutions was also examined, and the effect of structural nonlinearities associated with in-plane forces in the panel was considered on the worst case linear flutter solution. The results of the study indicated that adequate flutter margins exist for the panel at the Mach numbers examined. The addition of structural damping improved flutter margins as did the inclusion of nonlinear effects associated with a static pressure difference across the panel.

  1. Experimental parametric studies of transonic T-tail flutter. [wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Ruhlin, C. L.; Sandford, M. C.

    1975-01-01

    Wind-tunnel tests of the T-tail of a wide-body jet airplane were made at Mach numbers up to 1.02. The model consisted of a 1/13-size scaled version of the T-tail, fuselage, and inboard wing of the airplane. Two interchangeable T-tails were tested, one with design stiffness for flutter-clearance studies and one with reduced stiffness for flutter-trend studies. Transonic antisymmetric-flutter boundaries were determined for the models with variations in: (1) fin-spar stiffness, (2) stabilizer dihedral angle (-5 deg and 0 deg), (3) wing and forward-fuselage shape, and (4) nose shape of the fin-stabilizer juncture. A transonic symmetric-flutter boundary and flutter trends were established for variations in stabilizer pitch stiffness. Photographs of the test configurations are shown.

  2. Transonic flutter study of a wind-tunnel model of a supercritical wing with/without winglet. [conducted in Langley Transonic Dynamics Tunnel

    NASA Technical Reports Server (NTRS)

    Ruhlin, C. L.; Rauch, F. J., Jr.; Waters, C.

    1982-01-01

    The model was a 1/6.5-size, semipan version of a wing proposed for an executive-jet-transport airplane. The model was tested with a normal wingtip, a wingtip with winglet, and a normal wingtip ballasted to simulate the winglet mass properties. Flutter and aerodynamic data were acquired at Mach numbers (M) from 0.6 to 0.95. The measured transonic flutter speed boundary for each wingtip configuration had roughly the same shape with a minimum flutter speed near M=0.82. The winglet addition and wingtip mass ballast decreased the wing flutter speed by about 7 and 5 percent, respectively; thus, the winglet effect on flutter was more a mass effect than an aerodynamic effect.

  3. Application of a flight test and data analysis technique to flutter of a drone aircraft

    NASA Technical Reports Server (NTRS)

    Bennett, R. M.; Abel, I.

    1981-01-01

    Modal identification results are presented that were obtained from recent flight flutter tests of a drone vehicle with a research wing equipped with an active flutter suppression system (FSS). Frequency and damping of several modes are determined by a time domain modal analysis of the impulse response function obtained by Fourier transformations of data from fast swept sine wave excitation by the FSS control surfaces on the wing. Flutter points are determined for two different altitudes with the FSS off. Data are given for near the flutter boundary with the FSS on.

  4. [Sedation and anesthesia in dogs and cats with cardiovascular disease. II. Anesthesia planning with respect to pathophysiology, heart arrhythmia].

    PubMed

    Skarda, R T; Muir, W W; Bednarski, R M; Hubbell, J A; Mason, D E

    1995-01-01

    The purpose of this study was to review the incidence of cardiac arrhythmias in 137 anesthetized dogs and 13 anesthetized cats with congenital or acquired heart disease that were referred for correction of following procedures: patent ductus arteriosus (PDA-ligation, 28%), cardiac catheterization with angiogram and angioplasty (22%), pacemaker implantation (18%), exploratory lateral thoracotomy (8.7%), correction of right aortic arch (ring anomaly, 3.3%), correction of subvalvular aortic stenosis (2.7%), correction of PDA with coil in patients with mitral regurgitation and congestive heart failure (2%), pericardectomy and removal of heart base tumor (2%), and palliative surgery for ventricular septal defect (VSD, 0.7%). The anesthetic plan considered the risks of anesthesia based upon the pathophysiology of cardiac lesions and the anesthetic drug effects on the cardiovascular system. Recommendations are made for dogs with decreased cardiac contractility, cardiac disease with volume overload, cardiac disease with pressure overload, and pericardial tamponade. The percentages of animals and their associated cardiac arrhythmias after premedication and during and after anesthesia were: sinus bradycardia (15.3%), sinus tachycardia (3.3%), atrial flutter (0.7%), atrial fibrillation (0.7%), premature ventricular contraction (14%), and ventricular tachycardia (1.3%). Prompt therapy was given to a percentage of animals in order to control arrhythmia and support cardiovascular system, by using atropine or glycopyrrolate (14%), lidocaine (17.3%), and dopamine (14.7%).(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Fine Particulate air Pollution is Associated with Higher Vulnerability to Atrial Fibrillation—The APACR Study

    PubMed Central

    Liao, Duanping; Shaffer, Michele L.; He, Fan; Rodriguez-Colon, Sol; Wu, Rongling; Whitsel, Eric A.; Bixler, Edward O.; Cascio, Wayne E.

    2011-01-01

    The acute effects and the time course of fine particulate pollution (PM2.5) on atrial fibrillation/flutter (AF) predictors, including P-wave duration, PR interval duration, and P-wave complexity, were investigated in a community-dwelling sample of 106 nonsmokers. Individual-level 24-h beat-to-beat electrocardiogram (ECG) data were visually examined. After identifying and removing artifacts and arrhythmic beats, the 30-min averages of the AF predictors were calculated. A personal PM2.5 monitor was used to measure individual-level, real-time PM2.5 exposures during the same 24-h period, and corresponding 30-min average PM2.5 concentration were calculated. Under a linear mixed-effects modeling framework, distributed lag models were used to estimate regression coefficients (βs) associating PM2.5 with AF predictors. Most of the adverse effects on AF predictors occurred within 1.5–2 h after PM2.5 exposure. The multivariable adjusted βs per 10-µg/m3 rise in PM2.5 at lag 1 and lag 2 were significantly associated with P-wave complexity. PM2.5 exposure was also significantly associated with prolonged PR duration at lag 3 and lag 4. Higher PM2.5 was found to be associated with increases in P-wave complexity and PR duration. Maximal effects were observed within 2 h. These findings suggest that PM2.5 adversely affects AF predictors; thus, PM2.5 may be indicative of greater susceptibility to AF. PMID:21480044

  6. Severe tricuspid regurgitation in the aged: atrial remodeling associated with long-standing atrial fibrillation.

    PubMed

    Yamasaki, Naohito; Kondo, Fumiaki; Kubo, Toru; Okawa, Makoto; Matsumura, Yoshihisa; Kitaoka, Hiroaki; Yabe, Toshikazu; Furuno, Takashi; Doi, Yoshinori

    2006-12-01

    Severe idiopathic tricuspid regurgitation (TR) occurs in the aged, but the mechanism of TR is unclear and there is little information on atrial abnormalities associated with this condition. This study retrospectively analyzed patients with severe functional TR presenting with common clinical features suggesting a distinct syndrome. Eleven patients with severe functional TR were identified by reviewing the records of 16,235 consecutive patients. All patients had undergone clinical evaluation including echocardiography, electrocardiography and laboratory data. The median age of patients with severe functional TR was 78 years. All had a long-standing history of atrial fibrillation (median duration, 23 years). Clinical features are characterized by severe functional TR due to annular dilation, markedly dilated right atrium, episodes of right-sided heart failure, absent or diminished fibrillation waves on electrocardiogram, bradycardia probably due to partial atrial standstill, and decreased atrial natriuretic peptide secretion. During long-term follow up, right atrial size progressively increased in association with worsening TR. Severe functional TR occurs with long-standing atrial fibrillation and causes right-sided heart failure. The TR is caused by tricuspid valve systolic coaptation loss due to tricuspid annular dilation associated with atrial dilation. This condition is associated with atrial abnormalities, such as atrial standstill and impaired atrial natriuretic peptide secretion. We propose that atrial remodeling associated with atrial fibrillation is central to the occurrence of the syndrome.

  7. Effect of Omega-3 Polyunsaturated Fatty Acid Supplementation in Patients with Atrial Fibrillation.

    PubMed

    Kumar, Sanjay; Qu, Sarah; Kassotis, John T

    2012-01-01

    Atrial fibrillation (AF) is the most common sustained atrial arrhythmia conferring a higher morbidity and mortality. Despite the increasing incidence of AF; available therapies are far from perfect. Dietary fish oils, containing omega 3 fatty acids, also called polyunsaturated fatty acid [PUFA] have demonstrated beneficial electrophysiological, autonomic and anti-inflammatory effects on both atrial and ventricular tissue. Multiple clinical trials, focusing on various subsets of patients with AF, have studied the role of PUFA and their potential role in reducing the incidence of this common arrhythmia. While PUFA appears to have a beneficial effect in the primary prevention of AF in the elderly with structural heart disease, this benefit has not been universally observed. In the secondary prevention of AF, PUFA seems to have a greater impact in the reducing AF in patients with paroxysmal or persistent AF, stages of AF associated with less atrial fibrosis and negative structural remodeling. However, AF suppression has not been consistently demonstrated in clinical trials. In patients undergoing heart surgery, increasing PUFA intake has yielded mixed results in terms of AF prevention post-operatively; however, increased PUFA has been associated with a reduction in hospital stay. Therefore recommending the use of PUFA for the purpose of AF reduction remains controversial. This is in part attributable to the complexity of AF. Other conflicting variables include: heterogeneous patient populations studied; variable dosing; duration of follow-up; comorbidities; and, concomitant pharmacotherapy. This review article reviews in detail available basic and clinical research studies of fish oil in the treatment of AF, and its role in the treatment of this common disorder. AF=Atrial fibrillation, CHS=Cardiovascular Health Study,CABG=Coronary artery bypass surgery, d=Day, DHA=Docosahexaenoic acid, EPA=Eicosapentaenoic acid, ERP= Effective refractory period, g=Gram, PAF= Paroxysmal atrial fibrillation, PeAF= Persistent atrial fibrillation PUFA= Polyunsaturated fatty acid.

  8. The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias

    PubMed Central

    Bauernfeind, Tamas; Akca, Ferdi; Schwagten, Bruno; de Groot, Natasja; Van Belle, Yves; Valk, Suzanne; Ujvari, Barbara; Jordaens, Luc; Szili-Torok, Tamas

    2011-01-01

    Aims We aimed to evaluate the safety and long-term efficacy of the magnetic navigation system (MNS) in a large number of patients. The MNS has the potential for improving safety and efficacy based on atraumatic catheter design and superior navigation capabilities. Methods and results In this study, 610 consecutive patients underwent ablation. Patients were divided into two age- and sex-matched groups. Ablations were performed either using MNS (group MNS, 292) or conventional manual ablation [group manual navigation (MAN), 318]. The following parameters were analysed: acute success rate, fluoroscopy time, procedure time, complications [major: pericardial tamponade, permanent atrioventricular (AV) block, major bleeding, and death; minor: minor bleeding and temporary AV block]. Recurrence rate was assessed during follow-up (15 ± 9.5 months). Subgroup analysis was performed for the following groups: atrial fibrillation, isthmus dependent and atypical atrial flutter, atrial tachycardia, AV nodal re-entrant tachycardia, circus movement tachycardia, and ventricular tachycardia (VT). Magnetic navigation system was associated with less major complications (0.34 vs. 3.2%, P = 0.01). The total numbers of complications were lower in group MNS (4.5 vs. 10%, P = 0.005). Magnetic navigation system was equally effective as MAN in acute success rate for overall groups (92 vs. 94%, P = ns). Magnetic navigation system was more successful for VTs (93 vs. 72%, P < 0.05). Less fluoroscopy was used in group MNS (30 ± 20 vs. 35 ± 25 min, P < 0.01). There were no differences in procedure times and recurrence rates for the overall groups (168 ± 67 vs. 159 ± 75 min, P = ns; 14 vs. 11%, P = ns; respectively). Conclusions Our data suggest that the use of MNS improves safety without compromising efficiency of ablations. Magnetic navigation system is more effective than manual ablation for VTs. PMID:21508006

  9. Electrophysiologic effects of a novel selective adenosine A1 agonist (CVT-510) on atrioventricular nodal conduction in humans.

    PubMed

    Lerman, B B; Ellenbogen, K A; Kadish, A; Platia, E; Stein, K M; Markowitz, S M; Mittal, S; Slotwiner, D J; Scheiner, M; Iwai, S; Belardinelli, L; Jerling, M; Shreeniwas, R; Wolff, A A

    2001-07-01

    CVT-510, N-(3(R)-tetrahydrofuranyl)-6-aminopurine riboside, is a selective A(1)-adenosine receptor agonist with potential potent antiarrhythmic effects in tachycardias involving the atrioventricular (AV) node. This study, the first in humans, was designed to determine the effects of CVT-510 on AV nodal conduction and hemodynamics. Patients in sinus rhythm with normal AV nodal function at electrophysiologic study (n = 32) received a single intravenous bolus of CVT-510. AH and HV intervals were measured during sinus rhythm and during atrial pacing at 1, 5, 10, 15, 20, 30, 45, and 60 minutes after the bolus. Increasing doses of CVT-510 (0.3 to 10 microg/kg) caused a dose-dependent increase in the AH interval. At 1 minute, a dose of 10 microg/kg increased the AH interval during sinus rhythm from 93 +/- 23 msec to 114 +/- 37 msec, p = 0.01 and from 114 +/- 31 msec to 146 +/- 44 msec during atrial pacing at 600 msec, p = 0.003). The AH interval returned to baseline by 20 minutes. CVT-510 at doses of 0.3 to 10 microg/kg had no effect on sinus rate, HV interval, or systemic blood pressure, and was not associated with serious adverse effects. At doses of 15 and 30 microg/kg, CVT-510 produced transient second/third degree AV heart block in all four patients treated. One of these patients also had a prolonged sedative effect that was reversed with aminophylline. CVT-510 promptly prolongs AV nodal conduction and does not affect sinus rate or blood pressure. Selective stimulation of the A(1)-adenosine receptor by CVT-510 may be useful for immediate control of heart rate in atrial fibrillation/flutter and to convert paroxysmal supraventricular tachycardia to sinus rhythm, while avoiding vasodilatation mediated by the A(2)-adenosine receptor, as well as the vasodepressor and negative inotropic effects associated with beta-adrenergic receptor blockade and/or calcium channel blockers.

  10. Computed and Experimental Flutter/LCO Onset for the Boeing Truss-Braced Wing Wind-Tunnel Model

    NASA Technical Reports Server (NTRS)

    Bartels, Robert E.; Scott, Robert C.; Funk, Christie J.; Allen, Timothy J.; Sexton, Bradley W.

    2014-01-01

    This paper presents high fidelity Navier-Stokes simulations of the Boeing Subsonic Ultra Green Aircraft Research truss-braced wing wind-tunnel model and compares the results to linear MSC. Nastran flutter analysis and preliminary data from a recent wind-tunnel test of that model at the NASA Langley Research Center Transonic Dynamics Tunnel. The simulated conditions under consideration are zero angle of attack, so that structural nonlinearity can be neglected. It is found that, for Mach number greater than 0.78, the linear flutter analysis predicts flutter onset dynamic pressure below the wind-tunnel test and that predicted by the Navier-Stokes analysis. Furthermore, the wind-tunnel test revealed that the majority of the high structural dynamics cases were wing limit cycle oscillation (LCO) rather than flutter. Most Navier-Stokes simulated cases were also LCO rather than hard flutter. There is dip in the wind-tunnel test flutter/LCO onset in the Mach 0.76-0.80 range. Conditions tested above that Mach number exhibited no aeroelastic instability at the dynamic pressures reached in the tunnel. The linear flutter analyses do not show a flutter/LCO dip. The Navier-Stokes simulations also do not reveal a dip; however, the flutter/LCO onset is at a significantly higher dynamic pressure at Mach 0.90 than at lower Mach numbers. The Navier-Stokes simulations indicate a mild LCO onset at Mach 0.82, then a more rapidly growing instability at Mach 0.86 and 0.90. Finally, the modeling issues and their solution related to the use of a beam and pod finite element model to generate the Navier-Stokes structure mode shapes are discussed.

  11. Novel ion channel targets in atrial fibrillation.

    PubMed

    Hancox, Jules C; James, Andrew F; Marrion, Neil V; Zhang, Henggui; Thomas, Dierk

    2016-08-01

    Atrial fibrillation (AF) is the most common arrhythmia in humans. It is progressive and the development of electrical and structural remodeling makes early intervention desirable. Existing antiarrhythmic pharmacological approaches are not always effective and can produce unwanted side effects. Additional atrial-selective antiarrhythmic strategies are therefore desirable. Evidence for three novel ion channel atrial-selective therapeutic targets is evaluated: atrial-selective fast sodium channel current (INa) inhibition; small conductance calcium-activated potassium (SK) channels; and two-pore (K2P) potassium channels. Data from animal models support atrial-ventricular differences in INa kinetics and also suggest atrial-ventricular differences in sodium channel β subunit expression. Further work is required to determine whether intrinsic atrial-ventricular differences in human INa exist or whether functional differences occur due to distinct atrial and ventricular action and resting potentials. SK and K2P channels (particularly K2P 3.1) offer potentially attractive atrial-selective targets. Work is needed to identify the underlying basis of SK current that contributes to (patho)physiological atrial repolarization and settings in which SK inhibition is anti- versus pro-arrhythmic. Although K2P3.1 appears to be a promising target with comparatively selective drugs for experimental use, a lack of selective pharmacology hinders evaluation of other K2P channels as potential atrial-selective targets.

  12. Optical detection of blade flutter. [in YF-100 turbofan engine

    NASA Technical Reports Server (NTRS)

    Nieberding, W. C.; Pollack, J. L.

    1977-01-01

    The paper examines the capabilities of photoelectric scanning (PES) and stroboscopic imagery (SI) as optical monitoring tools for detection of the onset of flutter in the fan blades of an aircraft gas turbine engine. Both optical techniques give visual data in real time as well as video-tape records. PES is shown to be an ideal flutter monitor, since a single cathode ray tube displays the behavior of all the blades in a stage simultaneously. Operation of the SI system continuously while searching for a flutter condition imposes severe demands on the flash tube and affects its reliability, thus limiting its use as a flutter monitor. A better method of operation is to search for flutter with the PES and limit the use of SI to those times when the PES indicates interesting blade activity.

  13. Evaluation of somatosensory cortical differences between flutter and vibration tactile stimuli.

    PubMed

    Han, Sang Woo; Chung, Yoon Gi; Kim, Hyung-Sik; Chung, Soon-Cheol; Park, Jang-Yeon; Kim, Sung-Phil

    2013-01-01

    In parallel with advances in haptic-based mobile computing systems, understanding of the neural processing of vibrotactile information becomes of great importance. In the human nervous system, two types of vibrotactile information, flutter and vibration, are delivered from mechanoreceptors to the somatosensory cortex through segregated neural afferents. To investigate how the somatosensory cortex differentiates flutter and vibration, we analyzed the cortical responses to vibrotactile stimuli with a wide range of frequencies. Specifically, we examined whether cortical activity changed most around 50 Hz, which is known as a boundary between flutter and vibration. We explored various measures to evaluate separability of cortical activity across frequency and found that the hypothesis margin method resulted in the greatest separability between flutter and vibration. This result suggests that flutter and vibration information may be processed by different neural processes in the somatosensory cortex.

  14. Developing Uncertainty Models for Robust Flutter Analysis Using Ground Vibration Test Data

    NASA Technical Reports Server (NTRS)

    Potter, Starr; Lind, Rick; Kehoe, Michael W. (Technical Monitor)

    2001-01-01

    A ground vibration test can be used to obtain information about structural dynamics that is important for flutter analysis. Traditionally, this information#such as natural frequencies of modes#is used to update analytical models used to predict flutter speeds. The ground vibration test can also be used to obtain uncertainty models, such as natural frequencies and their associated variations, that can update analytical models for the purpose of predicting robust flutter speeds. Analyzing test data using the -norm, rather than the traditional 2-norm, is shown to lead to a minimum-size uncertainty description and, consequently, a least-conservative robust flutter speed. This approach is demonstrated using ground vibration test data for the Aerostructures Test Wing. Different norms are used to formulate uncertainty models and their associated robust flutter speeds to evaluate which norm is least conservative.

  15. Further studies of stall flutter and nonlinear divergence of two-dimensional wings

    NASA Technical Reports Server (NTRS)

    Dugundji, J.; Chopra, I.

    1975-01-01

    An experimental investigation is made of the purely torsional stall flutter of a two-dimensional wing pivoted about the midchord, and also of the bending-torsion stall flutter of a two-dimensional wing pivoted about the quarterchord. For the purely torsional flutter case, large amplitude limit cycles ranging from + or - 11 to + or - 160 degrees were observed. Nondimensional harmonic coefficients were extracted from the free transient vibration tests for amplitudes up to 80 degrees. Reasonable nondimensional correlation was obtained for several wing configurations. For the bending-torsion flutter case, large amplitude coupled limit cycles were observed with torsional amplitudes as large as + or - 40 degrees. The torsion amplitudes first increased, then decreased with increasing velocity. Additionally, a small amplitude, predominantly torsional flutter was observed when the static equilibrium angle was near the stall angle.

  16. An Interactive Software for Conceptual Wing Flutter Analysis and Parametric Study

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1996-01-01

    An interactive computer program was developed for wing flutter analysis in the conceptual design stage. The objective was to estimate the flutter instability boundary of a flexible cantilever wing, when well-defined structural and aerodynamic data are not available, and then study the effect of change in Mach number, dynamic pressure, torsional frequency, sweep, mass ratio, aspect ratio, taper ratio, center of gravity, and pitch inertia, to guide the development of the concept. The software was developed for Macintosh or IBM compatible personal computers, on MathCad application software with integrated documentation, graphics, data base and symbolic mathematics. The analysis method was based on non-dimensional parametric plots of two primary flutter parameters, namely Regier number and Flutter number, with normalization factors based on torsional stiffness, sweep, mass ratio, taper ratio, aspect ratio, center of gravity location and pitch inertia radius of gyration. The parametric plots were compiled in a Vought Corporation report from a vast data base of past experiments and wind-tunnel tests. The computer program was utilized for flutter analysis of the outer wing of a Blended-Wing-Body concept, proposed by McDonnell Douglas Corp. Using a set of assumed data, preliminary flutter boundary and flutter dynamic pressure variation with altitude, Mach number and torsional stiffness were determined.

  17. Right ventricular sarcoidosis: is it time for updated diagnostic criteria?

    PubMed

    Vakil, Kairav; Minami, Elina; Fishbein, Daniel P

    2014-04-01

    A 55-year-old woman with a history of complete heart block, atrial flutter, and progressive right ventricular failure was referred to our tertiary care center to be evaluated for cardiac transplantation. The patient's clinical course included worsening right ventricular dysfunction for 3 years before the current evaluation. Our clinical findings raised concerns about arrhythmogenic right ventricular cardiomyopathy. Noninvasive imaging, including a positron emission tomographic scan, did not reveal obvious myocardial pathologic conditions. Given the end-stage nature of the patient's right ventricular failure and her dependence on inotropic agents, she underwent urgent listing and subsequent heart transplantation. Pathologic examination of the explanted heart revealed isolated right ventricular sarcoidosis with replacement fibrosis. Biopsy samples of the cardiac allograft 6 months after transplantation showed no recurrence of sarcoidosis. This atypical presentation of isolated cardiac sarcoidosis posed a considerable diagnostic challenge. In addition to discussing the patient's case, we review the relevant medical literature and discuss the need for updated differential diagnostic criteria for end-stage right ventricular failure that mimics arrhythmogenic right ventricular cardiomyopathy.

  18. Flutter suppression digital control law design and testing for the AFW wind tunnel model

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1994-01-01

    The design of a control law for simultaneously suppressing the symmetric and antisymmetric flutter modes of a sting mounted fixed-in-roll aeroelastic wind-tunnel model is described. The flutter suppression control law was designed using linear quadratic Gaussian theory, and it also involved control law order reduction, a gain root-locus study, and use of previous experimental results. A 23 percent increase in the open-loop flutter dynamic pressure was demonstrated during the wind-tunnel test. Rapid roll maneuvers at 11 percent above the symmetric flutter boundary were also performed when the model was in a free-to-roll configuration.

  19. Comparison of analytical and wind-tunnel results for flutter and gust response of a transport wing with active controls

    NASA Technical Reports Server (NTRS)

    Abel, I.; Perry, B., III; Newsom, J. R.

    1982-01-01

    Two flutter suppression control laws wre designed and tested on a low speed aeroelastic model of a DC-10 derivative wing. Both control laws demontrated increases in flutter speed in excess of 25 percent above the passive wing flutter speed. In addition, one of the control laws was effective in reducing loads due to turbulence generated in the wind tunnel. The effect of variations in gain and phase on the closed-loop performance was measured and is compared with predictions. In general, both flutter and gust response predictions agree reasonably well with experimental data.

  20. Flutter suppression digital control law design and testing for the AFW wind tunnel model

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1992-01-01

    Design of a control law for simultaneously suppressing the symmetric and antisymmetric flutter modes of a sting mounted fixed-in-roll aeroelastic wind tunnel model is described. The flutter suppression control law was designed using linear quadratic Gaussian theory, and involved control law order reduction, a gain root-locus study and use of previous experimental results. A 23 percent increase in the open-loop flutter dynamic pressure was demonstrated during the wind tunnel test. Rapid roll maneuvers at 11 percent above the symmetric flutter boundary were also performed when the model was in a free-to-roll configuration.

  1. Flutter suppression digital control law design and testing for the AFW wind-tunnel model

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1992-01-01

    Design of a control law for simultaneously suppressing the symmetric and antisymmetric flutter modes of a string mounted fixed-in-roll aeroelastic wind tunnel model is described. The flutter suppression control law was designed using linear quadratic Gaussian theory and involved control law order reduction, a gain root-locus study, and the use of previous experimental results. A 23 percent increase in open-loop flutter dynamic pressure was demonstrated during the wind tunnel test. Rapid roll maneuvers at 11 percent above the symmetric flutter boundary were also performed when the model was in a free-to-roll configuration.

  2. Sensitivity Analysis of Flutter Response of a Wing Incorporating Finite-Span Corrections

    NASA Technical Reports Server (NTRS)

    Issac, Jason Cherian; Kapania, Rakesh K.; Barthelemy, Jean-Francois M.

    1994-01-01

    Flutter analysis of a wing is performed in compressible flow using state-space representation of the unsteady aerodynamic behavior. Three different expressions are used to incorporate corrections due to the finite-span effects of the wing in estimating the lift-curve slope. The structural formulation is based on a Rayleigh-Pitz technique with Chebyshev polynomials used for the wing deflections. The aeroelastic equations are solved as an eigen-value problem to determine the flutter speed of the wing. The flutter speeds are found to be higher in these cases, when compared to that obtained without accounting for the finite-span effects. The derivatives of the flutter speed with respect to the shape parameters, namely: aspect ratio, area, taper ratio and sweep angle, are calculated analytically. The shape sensitivity derivatives give a linear approximation to the flutter speed curves over a range of values of the shape parameter which is perturbed. Flutter and sensitivity calculations are performed on a wing using a lifting-surface unsteady aerodynamic theory using modules from a system of programs called FAST.

  3. An experimental and analytical investigation of the effect of spanwise curvature on wing flutter at Mach number of 0.7

    NASA Technical Reports Server (NTRS)

    Rivera, Jose A., Jr.

    1989-01-01

    An experimental and analytical study was conducted at Mach 0.7 to investigate the effects of spanwise curvature on flutter. Two series of rectangular planform wings of aspect ration 1.5 and curvature ranging from zero (uncurved) to 1.04/ft were flutter tested in the NASA Langley Transonic Dynamics Tunnel (TDT). One series consisted of models with a NACA 65 A010 airfoil section and the other of flat plate cross section models. Flutter analyses were conducted for correlation with the experimental results by using structural finite element methods to perform vibration analysis and two aerodynamic theories to obtain unsteady aerodynamic load calculations. The experimental results showed that for one series of models the flutter dynamic pressure increased significantly with curvature while for the other series of models the flutter dynamic pressure decreased with curvature. The flutter analyses, which generally predicted the experimental results, indicated that the difference in behavior of the two series of models was primarily due to differences in their structural properties.

  4. Ch-47C Fixed-System Stall-Flutter Damping

    DTIC Science & Technology

    1975-08-01

    flutter. The steady and vibratory loads in the cyclic-trim linkage are so related that motions across the control system’s mechan- ical free play could...be a significant part of the stall-flutter motion, depending on the magnitude of the free play . For this reason it is recommended that future testing...include the deter- mination of the effects of control-system free play on the stall-flutter responses. , f ,**~ - ,***,- * **4 , - - *. i

  5. Passive Wireless Vibration Sensing for Measuring Aerospace Structural Flutter

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.

    2017-01-01

    To reduce energy consumption, emissions, and noise, NASA is exploring the use of high aspect ratio wings on subsonic aircraft. Because high aspect ratio wings are susceptible to flutter events, NASA is also investigating methods of flutter detection and suppression. In support of that work a new remote, non-contact method for measuring flutter-induced vibrations has been developed. The new sensing scheme utilizes a microwave reflectometer to monitor the reflected response from an aeroelastic structure to ultimately characterize structural vibrations. To demonstrate the ability of microwaves to detect flutter vibrations, a carbon fiber-reinforced polymer (CFRP) composite panel was vibrated at various frequencies from 1Hz to 130Hz. The reflectometer response was found to closely resemble the sinusoidal response as measured with an accelerometer up to 100 Hz. The data presented demonstrate that microwaves can be used to measure flutter-induced aircraft vibrations.

  6. Final design and fabrication of an active control system for flutter suppression on a supercritical aeroelastic research wing

    NASA Technical Reports Server (NTRS)

    Hodges, G. E.; Mcgehee, C. R.

    1981-01-01

    The final design and hardware fabrication was completed for an active control system capable of the required flutter suppression, compatible with and ready for installation in the NASA aeroelastic research wing number 1 (ARW-1) on Firebee II drone flight test vehicle. The flutter suppression system uses vertical acceleration at win buttock line 1.930 (76), with fuselage vertical and roll accelerations subtracted out, to drive wing outboard aileron control surfaces through appropriate symmetric and antisymmetric shaping filters. The goal of providing an increase of 20 percent above the unaugmented vehicle flutter velocity but below the maximum operating condition at Mach 0.98 is exceeded by the final flutter suppression system. Results indicate that the flutter suppression system mechanical and electronic components are ready for installation on the DAST ARW-1 wing and BQM-34E/F drone fuselage.

  7. Real-time flutter boundary prediction based on time series models

    NASA Astrophysics Data System (ADS)

    Gu, Wenjing; Zhou, Li

    2018-03-01

    For the purpose of predicting the flutter boundary in real time during flutter flight tests, two time series models accompanied with corresponding stability criterion are adopted in this paper. The first method simplifies a long nonstationary response signal as many contiguous intervals and each is considered to be stationary. The traditional AR model is then established to represent each interval of signal sequence. While the second employs a time-varying AR model to characterize actual measured signals in flutter test with progression variable speed (FTPVS). To predict the flutter boundary, stability parameters are formulated by the identified AR coefficients combined with Jury's stability criterion. The behavior of the parameters is examined using both simulated and wind-tunnel experiment data. The results demonstrate that both methods show significant effectiveness in predicting the flutter boundary at lower speed level. A comparison between the two methods is also given in this paper.

  8. Selected topics in experimental aeroelasticity at the NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Ricketts, R. H.

    1985-01-01

    The results of selected studies that have been conducted by the NASA Langley Research Center in the last three years are presented. The topics presented focus primarily on the ever-important transonic flight regime and include the following: body-freedom flutter of a forward-swept-wing configuration with and without relaxed static stability; instabilities associated with a new tilt-rotor vehicle; effects of winglets, supercritical airfoils, and spanwise curvature on wing flutter; wind-tunnel investigation of a flutter-like oscillation on a high-aspect-ratio flight research wing; results of wing-tunnel demonstration of the NASA decoupler pylon concept for passive suppression of wing/store flutter; and, new flutter testing methods which include testing at cryogenic temperatures for full scale Reynolds number simulation, subcritical response techniques for predicting onset of flutter, and a two-degree-of-freedom mount system for testing side-wall-mounted models.

  9. Selected topics in experimental aeroelasticity at the NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Ricketts, R. H.

    1985-01-01

    The results of selected studies that have been conducted by the NASA Langley Research Center in the last three years are presented. The topics presented focus primarily on the ever-important transonic flight regime and include the following: body-freedom flutter of a forward-swept-wing configuration with and without relaxed static stability; instabilities associated with a new tilt-rotor vehicle; effects of winglets, supercritical airfoils, and spanwise curvature on wing flutter; wind-tunnel investigation of a flutter-like oscillation on a high-aspect-ratio flight research wing; results of wind-tunnel demonstration of the NASA decoupler pylon concept for passive suppression of wing/store flutter; and, new flutter testing methods which include testing at cryogenic temperatures for full scale Reynolds number simulation, subcritical response techniques for predicting onset of flutter, and a two-degree-of-freedom mount system for testing side-wall-mounted models.

  10. Preliminary study of effects of winglets on wing flutter

    NASA Technical Reports Server (NTRS)

    Doggett, R. V., Jr.; Farmer, M. G.

    1976-01-01

    Some experimental flutter results are presented over a Mach number range from about 0.70 to 0.95 for a simple, swept, tapered, flat-plate wing model having a planform representative of subsonic transport airplanes and for the same wing model equipped with two different upper surface winglets. Both winglets had the same planform and area (about 2 percent of the basic-wing area); however, one weighed about 0.3 percent of the basic-wing weight, and the other weighed about 1.8 percent of the wing weight. The addition of the lighter winglet reduced the wing-flutter dynamic pressure by about 3 percent; the heavier winglet reduced the wing-flutter dynamic pressure by about 12 percent. The experimental flutter results are compared at a Mach number of 0.80 with analytical flutter results obtained by using doublet-lattice and lifting-surface (kernel-function) unsteady aerodynamic theories.

  11. A curve fitting method for solving the flutter equation. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Cooper, J. L.

    1972-01-01

    A curve fitting approach was developed to solve the flutter equation for the critical flutter velocity. The psi versus nu curves are approximated by cubic and quadratic equations. The curve fitting technique utilized the first and second derivatives of psi with respect to nu. The method was tested for two structures, one structure being six times the total mass of the other structure. The algorithm never showed any tendency to diverge from the solution. The average time for the computation of a flutter velocity was 3.91 seconds on an IBM Model 50 computer for an accuracy of five per cent. For values of nu close to the critical root of the flutter equation the algorithm converged on the first attempt. The maximum number of iterations for convergence to the critical flutter velocity was five with an assumed value of nu relatively distant from the actual crossover.

  12. Fall risk and anticoagulation for atrial fibrillation in the elderly: A delicate balance.

    PubMed

    Hagerty, Tracy; Rich, Michael W

    2017-01-01

    Guidelines for managing atrial fibrillation recommend systemic anticoagulation for almost all patients age 65 and older, but in practice up to 50% of older patients do not receive maintenance anticoagulation therapy. The most common reason physicians cite for withholding anticoagulation in older patients with atrial fibrillation is a perception of a high risk of falling and associated bleeding, especially intracranial hemorrhage. Copyright © 2017 Cleveland Clinic.

  13. Development and application of an optimization procedure for flutter suppression using the aerodynamic energy concept

    NASA Technical Reports Server (NTRS)

    Nissim, E.; Abel, I.

    1978-01-01

    An optimization procedure is developed based on the responses of a system to continuous gust inputs. The procedure uses control law transfer functions which have been partially determined by using the relaxed aerodynamic energy approach. The optimization procedure yields a flutter suppression system which minimizes control surface activity in a gust environment. The procedure is applied to wing flutter of a drone aircraft to demonstrate a 44 percent increase in the basic wing flutter dynamic pressure. It is shown that a trailing edge control system suppresses the flutter instability over a wide range of subsonic mach numbers and flight altitudes. Results of this study confirm the effectiveness of the relaxed energy approach.

  14. An influence coefficient method for the application of the modal technique to wing flutter suppression of the DAST ARW-1 wing

    NASA Technical Reports Server (NTRS)

    Pines, S.

    1981-01-01

    The methods used to compute the mass, structural stiffness, and aerodynamic forces in the form of influence coefficient matrices as applied to a flutter analysis of the Drones for Aerodynamic and Structural Testing (DAST) Aeroelastic Research Wing. The DAST wing was chosen because wind tunnel flutter test data and zero speed vibration data of the modes and frequencies exist and are available for comparison. A derivation of the equations of motion that can be used to apply the modal method for flutter suppression is included. A comparison of the open loop flutter predictions with both wind tunnel data and other analytical methods is presented.

  15. Active flutter suppression using dipole filters

    NASA Technical Reports Server (NTRS)

    Srinathkumar, S.; Waszak, Martin R.

    1992-01-01

    By using traditional control concepts of gain root locus, the active suppression of a flutter mode of a flexible wing is examined. It is shown that the attraction of the unstable mode towards a critical system zero determines the degree to which the flutter mode can be stabilized. For control situations where the critical zero is adversely placed in the complex plane, a novel compensation scheme called a 'Dipole' filter is proposed. This filter ensures that the flutter mode is stabilized with acceptable control energy. The control strategy is illustrated by designing flutter suppression laws for an active flexible wing (AFW) wind-tunnel model, where minimal control effort solutions are mandated by control rate saturation problems caused by wind-tunnel turbulence.

  16. Multi-fractality in aeroelastic response as a precursor to flutter

    NASA Astrophysics Data System (ADS)

    Venkatramani, J.; Nair, Vineeth; Sujith, R. I.; Gupta, Sayan; Sarkar, Sunetra

    2017-01-01

    Wind tunnel tests on a NACA 0012 airfoil have been carried out to study the transition in aeroelastic response from an initial state characterised by low-amplitude aperiodic fluctuations to aeroelastic flutter when the system exhibits limit cycle oscillations. An analysis of the aeroelastic measurements reveals multi-fractal characteristics in the pre-flutter regime. This has not been studied in the literature. As the flow velocity approaches the flutter velocity from below, a gradual loss in multi-fractality is observed. Measures based on the generalised Hurst exponents are developed and are shown to have the potential to warn against impending aeroelastic flutter. The results of this study could be useful for health monitoring of aeroelastic structures.

  17. Application of a flight test and data analysis technique to flutter of a drone aircraft

    NASA Technical Reports Server (NTRS)

    Bennett, R. M.

    1981-01-01

    Modal identification results presented were obtained from recent flight flutter tests of a drone vehicle with a research wing (DAST ARW-1 for Drones for Aerodynamic and Structural Testing, Aeroelastic Research Wing-1). This vehicle is equipped with an active flutter suppression system (FSS). Frequency and damping of several modes are determined by a time domain modal analysis of the impulse response function obtained by Fourier transformations of data from fast swept sine wave excitation by the FSS control surface on the wing. Flutter points are determined for two different altitudes with the FSS off. Data are given for near the flutter boundary with the FSS on.

  18. Some Effects of Sweep and Aspect Ratio on the Transonic Flutter Characteristics of a Series of Thin Cantilever Wings Having a Taper Ratio of 0.6

    NASA Technical Reports Server (NTRS)

    Jones, G. W., Jr.; Unangst, J. R.

    1963-01-01

    An investigation of the flutter characteristics of a series of thin cantilever wings having taper ratios of 0.6 was conducted in the Langley transonic blowdown tunnel at Mach numbers between 0.76 and 1.42. The angle of sweepback was varied from 0 degrees to 60 degrees on wings of aspect ratio 4, and the aspect ratio was varied from 2.4 to 6.4 on wings with 45 degrees of sweepback. The results are presented as ratios between the experimental flutter speeds and the reference flutter speeds calculated on the basis of incompressible two-dimensional flow. These ratios, designated the flutter-speed ratios, are given as functions of Mach number for the various wings. The flutter-speed ratios were characterized, in most cases, by values near 1.0 at subsonic speeds with large increases in the speed ratios in the range of supersonic speeds investigated. Increasing the sweep effected increases in the flutter-speed ratios between 0 degrees and 30 degrees followed by progressive reductions of the speed ratios to nearly 1.0 as the sweep was increased from 30 degrees to 60 degrees. Reducing the aspect ratio from 6.4 to 2.4 resulted in progressively larger values of the flutter-speed ratios throughout the Mach number range investigated.

  19. LED's and the "Fluttering Heart" Phenomenon.

    ERIC Educational Resources Information Center

    Jewett, John W., Jr.

    1993-01-01

    Describes the nineteenth-century parlor trick entitled the Fluttering Heart phenomenon which uses a red heart on a bright blue background. Discusses theories concerning the apparent fluttering. Suggests doing the trick with a red light-emitting diode in a darkened room. (MVL)

  20. Septum primum atrial septal defect in an infant with hypoplastic left heart syndrome.

    PubMed

    Loar, Robert W; Burkhart, Harold M; Taggart, Nathaniel W

    2014-08-01

    Hypoplastic left heart syndrome (HLHS) is a form of congenital heart disease characterized by severe underdevelopment of the left heart, leading to inadequate systemic blood flow. Several different atrial septal morphologies are observed in HLHS, most commonly a secundum atrial septal defect, patent foramen ovale, intact septum, and leftward displacement of the superior attachment of the septum primum. It has been postulated that atrial septal development is associated with the development of the left heart. We present a case of a newborn infant with HLHS and the unusual finding of a primum ASD.

  1. Effects of spoiler surfaces on the aeroelastic behavior of a low-aspect-ratio rectangular wing

    NASA Technical Reports Server (NTRS)

    Cole, Stanley R.

    1990-01-01

    An experimental research study to determine the effectiveness of spoiler surfaces in suppressing flutter onset for a low-aspect-ratio, rectangular wing was conducted in the Langley Transonic Dynamics Tunnel (TDT). The wing model used in this flutter test consisted of a rigid wing mounted to the wind-tunnel wall by a flexible, rectangular beam. The flexible beam was connected to the wing root and cantilever mounted to the wind-tunnel wall. The wing had a 1.5 aspect ratio based on wing semispan and a NACA 64A010 airfoil shape. The spoiler surfaces consisted of thin, rectangular aluminum plates that were vertically mounted to the wing surface. The spoiler surface geometry and location on the wing surface were varied to determine the effects of these parameters on the classical flutter of the wing model. Subsonically, the experiment showed that spoiler surfaces increased the flutter dynamic pressure with each successive increase in spoiler height or width. This subsonic increase in flutter dynamic pressure was approximately 15 percent for the maximum height spoiler configuration and for the maximum width spoiler configuration. At transonic Mach numbers, the flutter dynamic pressure conditions were increased even more substantially than at subsonic Mach numbers for some of the smaller spoiler surfaces. But greater than a certain spoiler size (in terms of either height or width) the spoilers forced a torsional instability in the transonic regime that was highly Mach number dependent. This detrimental torsional instability was found at dynamic pressures well below the expected flutter conditions. Variations in the spanwise location of the spoiler surfaces on the wing showed little effect on flutter. Flutter analysis was conducted for the basic configuration (clean wing with all spoiler surface mass properties included). The analysis correlated well with the clean wing experimental flutter results.

  2. Influence of mistuning on blade torsional flutter

    NASA Technical Reports Server (NTRS)

    Srinivasan, A. V.

    1980-01-01

    An analytical technique for the prediction of fan blade flutter was evaluated by utilizing first stage fan flutter data from tests on an advanced high performance engine. The formulation includes both aerodynamic and mechanical coupling among all the blades of the assembly. Mistuning is accounted for in the analysis so that individual blade inertias, frequencies, or damping can be considered. Airfoil stability was predicted by calculating a flutter determinant, the eigenvalues of which indicate the extent of susceptibility to flutter. When blade to blade differences in frequencies are considered, a stable system is predicted for the test points examined. For a tuned system, it was found that torsional flutter can be predicted at a limited number of interblade phase angles. Examination of these phase angles indicated that they were "close" to the condition of acoustic resonance. For the range of Mach numbers and reduced frequencies considered, the so called subcritical flutter cannot be predicted. The essential influence of mechanical coupling among the blades is to change the frequencies of the system with little or no change in damping; however, aerodynamic coupling together with mechanical coupling could change not only frequencies, but also damping in the system, with a trend toward instability.

  3. Low-energy cardioversion of spontaneous atrial fibrillation. Immediate and long-term results.

    PubMed

    Lévy, S; Ricard, P; Gueunoun, M; Yapo, F; Trigano, J; Mansouri, C; Paganelli, F

    1997-07-01

    Recent studies have suggested that induced atrial fibrillation (AF) could be successfully terminated by using a two-catheter electrode system and low energy (< 400 V). This study evaluated the efficacy and safety of low-energy cardioversion in spontaneous chronic and paroxysmal AF. Forty-two consecutive patients with spontaneous AF underwent low-energy electrical cardioversion. AF was chronic (> or = 1 month) with a mean duration of 9 +/- 19 months in 28 patients (group I) or paroxysmal with a history of recurrent attacks and a mean duration of the present episode of 7 +/- 16 days in 14 patients (group II). An underlying heart disease was present in 28 patients. A 3/3-ms biphasic shock was delivered between catheters positioned in the right atrium and the coronary sinus in 32 patients. In 10 patients, the left pulmonary artery branch was used. The catheters were connected to a custom external defibrillator. The shocks were synchronized to the R wave. Following a test shock of 60 V, the energy was increased in 40-V steps until a maximum of 400 V or restoration of sinus rhythm. Sinus rhythm was restored in 22 of the 28 patients (78%) of group I by using a mean leading-edge voltage of 297 +/- 57 V (mean energy 3.3 +/- 1.3 J) and in 11 of 14 patients (78%) of group II by using a mean leading-edge voltage of 223 +/- 41 V (mean energy, 1.8 +/- 0.7 J). The energy required for terminating chronic AF was significantly (P < .001) higher than that required for terminating paroxysmal AF. Among the other variables studied, the duration of AF significantly affected the successful voltage. Ventricular proarrhythmia occurred in 1 patient with atrial flutter due to an unsynchronized shock. Of the 22 patients of group I in whom sinus rhythm was restored, 14 (63%) remained in sinus rhythm with a mean follow-up of 9 +/- 3 months. Pain level showed a good correlation with increasing voltage. However, a marked inter-individual variation was noted. Atrial defibrillation using low energy between two intracardiac catheters with an electrical field between the right and left atria and the protocol used is feasible in patients with persistent spontaneous AF. The technique is safe provided synchronization to the R wave is achieved. A low recurrence rate of AF was seen in patients in whom sinus rhythm was restored.

  4. Second harmonic generation imaging of the collagen in myocardium for atrial fibrillation diagnosis

    NASA Astrophysics Data System (ADS)

    Tsai, Ming-Rung; Chiou, Yu-We; Sun, Chi-Kuang

    2009-02-01

    Myocardial fibrosis, a common sequela of cardiac hypertrophy, has been shown to be associated with arrhythmias in experimental models. Some research has indicated that myocardial fibrosis plays an important role in predisposing patients to atrial fibrillation. Second harmonic generation (SHG) is an optically nonlinear coherent process to image the collagen network. In this presentation, we observe the SHG images of the collagen matrix in atrial myocardium and we analyzed of collagen fibers arrangement by using Fourier-transform analysis. Moreover, comparing the SHG images of the collagen fibers in atrial myocardium between normal sinus rhythm (NSR) and atrial fibrillation (AF), our result indicated that it is possible to realize the relation between myocardial fibrosis and AF.

  5. Atrial Fibrillation and Gastro-Oesophageal Reflux Disease - Controversies and Challenges.

    PubMed

    Floria, Mariana; Barboi, Oana; Rezus, Ciprian; Ambarus, Valentin; Cijevschi-Prelipcean, Cristina; Balan, Gheorghe; Drug, Vasile Liviu

    2015-01-01

    Atrial fibrillation and gastro-oesophageal reflux are common manifestations in daily practice. The atria and the oesophagus are closely located and have similar nerve innervations. Over the last years, it has been observed that atrial fibrillation development and reflux disease could be related. Atrial fibrillation occurrence could be due to vagal nerve overstimulation. This, in association with vagal nerve-mediated parasympathetic stimulation, has also been observed in patients with gastro-oesophageal reflux. These mechanisms, in addition to inflammation, seem to be implicated in the pathophysiology of both diseases. Despite these associations supported by clinical and experimental studies, this relationship is still considered controversial. This review summarizes critical data regarding the association of gastro-oesophageal reflux and atrial fibrillation as well as their clinical implications.

  6. Anatomy of the left atrium for interventional electrophysiologists.

    PubMed

    Ho, Siew Yen; McCarthy, Karen P

    2010-05-01

    Increasingly, interventional procedures require accessing the left atrium from the inside of the heart as well as from the pericardial space. The right phrenic nerve running along the fibrous pericardium is close to the atrial insertion of the right superior pulmonary vein while the left phrenic nerve passes over the left atrial appendage. Posteriorly, the esophagus descends adjacent to the fibrous pericardium covering the posterior and postero-inferior walls of the left atrium. The component parts of the left atrium are reviewed with emphasis on the structure of the atrial septum, the left atrial ridge, the mitral isthmus, and the left atrial walls. Although the atrial walls are mainly smooth, pits and crevices are common in the region of the mitral isthmus and the vicinity of the os of the atrial appendage. The muscular rim around the valve of the oval fossa delimits the extent of the true atrial septum. Interatrial muscular connections exist at the septum, along Bachmann's bundle and also at the muscular sleeves of the coronary sinus and pulmonary veins. Anatomical features relevant to interventional electrophysiologists are highlighted.

  7. User's Guide for a Modular Flutter Analysis Software System (Fast Version 1.0)

    NASA Technical Reports Server (NTRS)

    Desmarais, R. N.; Bennett, R. M.

    1978-01-01

    The use and operation of a group of computer programs to perform a flutter analysis of a single planar wing are described. This system of programs is called FAST for Flutter Analysis System, and consists of five programs. Each program performs certain portions of a flutter analysis and can be run sequentially as a job step or individually. FAST uses natural vibration modes as input data and performs a conventional V-g type of solution. The unsteady aerodynamics programs in FAST are based on the subsonic kernel function lifting-surface theory although other aerodynamic programs can be used. Application of the programs is illustrated by a sample case of a complete flutter calculation that exercises each program.

  8. Analysis and test evaluation of the dynamic response and stability of three advanced turboprop models at low forward speed

    NASA Technical Reports Server (NTRS)

    Smith, Arthur F.

    1985-01-01

    Results of wind tunnel tests at low forward speed for blade dynamic response and stability of three 62.2 cm (24.5 in) diameter models of the Prop-Fan, advanced turboprop, are presented. Measurements of dynamic response were made with the rotors mounted on an isolated nacelle, with varying tilt for nonuniform inflow. Low speed stall flutter tests were conducted at Mach numbers from 0.0 to 0.35. Measurements are compared to Eigen-solution flutter boundaries. Calculated 1P stress response agrees favorably with experiment. Predicted stall flutter boundaries correlate well with measured high stress regions. Stall flutter is significantly reduced by increased blade sweep. Susceptibility to stall flutter decreases rapidly with forward speed.

  9. Robust Flutter Margin Analysis that Incorporates Flight Data

    NASA Technical Reports Server (NTRS)

    Lind, Rick; Brenner, Martin J.

    1998-01-01

    An approach for computing worst-case flutter margins has been formulated in a robust stability framework. Uncertainty operators are included with a linear model to describe modeling errors and flight variations. The structured singular value, mu, computes a stability margin that directly accounts for these uncertainties. This approach introduces a new method of computing flutter margins and an associated new parameter for describing these margins. The mu margins are robust margins that indicate worst-case stability estimates with respect to the defined uncertainty. Worst-case flutter margins are computed for the F/A-18 Systems Research Aircraft using uncertainty sets generated by flight data analysis. The robust margins demonstrate flight conditions for flutter may lie closer to the flight envelope than previously estimated by p-k analysis.

  10. Flutter calculations in three degrees of freedom

    NASA Technical Reports Server (NTRS)

    Theodorsen, Theodore; Garrick, I E

    1942-01-01

    The present paper is a continuation of the general study of flutter published in NACA reports nos. 496 and 685. The paper is mainly devoted to flutter in three degrees of freedom (bending, torsion, and aileron) for which a number of selected cases have been calculated and presented in graphical form. The results are analyzed and discussed with regard to the effects of structural damping, of fractional-span ailerons, and of mass-balancing. The analysis shows that more emphasis should be put on the effect of structural damping and less on mass-balancing. The conclusion is drawn that a definite minimum amount of structural damping, which is usually found to be present, is essential in the calculations for an adequate description of the flutter case. Theoretical flutter predictions are thus brought into closer agreement with the facts of experience. A brief discussion is included of a particular biplane that had experienced flutter at about 200 miles per hour. Some simplifications have been achieved in the method of calculation. (author)

  11. Rivaroxaban as an effective alternative to warfarin in a patient with atrial fibrillation, thrombophilia, and left atrial appendage thrombus: a case report.

    PubMed

    Scarano, Michele; Casale, Matteo; Mantini, Cesare; Imbalzano, Egidio; Consorti, Cristiana; Clemente, Daniela; Dattilo, Giuseppe

    2017-04-09

    Atrial fibrillation is the most common cardiac arrhythmia. It is responsible for up to 20% of all ischemic strokes. Rate control and anticoagulation are crucial for atrial fibrillation management and stroke prevention. We present the case of an 84-year-old Italian woman with a left atrial appendage thrombus that developed despite her use of anticoagulant therapy with warfarin for a previous pulmonary embolism. She had atrial fibrillation and heterozygosity for both factor V Leiden and methylenetetrahydrofolate reductase C677T mutation, thus creating resistance to activated protein C. Anticoagulant therapy was switched to heparin for 1 week and then to rivaroxaban. After 3 months of rivaroxaban use, the thrombus disappeared. This case raises the issue of the ineffectiveness of warfarin therapy in complex cases involving particular thrombophilic conditions and the possibility of using rivaroxaban as a safe and effective alternative.

  12. New Insights Into an Old Arrhythmia: High-Resolution Mapping Demonstrates Conduction and Substrate Variability in Right Atrial Macro-Re-Entrant Tachycardia.

    PubMed

    Pathik, Bhupesh; Lee, Geoffrey; Sacher, Frédéric; Jaïs, Pierre; Massoullié, Grégoire; Derval, Nicolas; Bates, Matthew G; Lipton, Jonathan; Joseph, Stephen; Morton, Joseph; Sparks, Paul; Kistler, Peter; Kalman, Jonathan M

    2017-09-01

    Using high-resolution 3-dimensional (3D) mapping, the aim of this study was to further characterize right atrial macro-re-entrant tachycardias and answer unresolved questions in the understanding of this arrhythmia. Despite advances in understanding of the mechanisms of right atrial macro-re-entrant tachycardias, many questions lack definitive answers. The advent of high-resolution 3D mapping provides an opportunity to gain further insights into the nature of these common circuits. A total of 25 patients with right atrial macro-re-entrant tachycardia were studied. High-resolution 3D mapping (Rhythmia mapping system, Boston Scientific, Natick, Massachusetts) was performed. Regional voltage and conduction velocity were determined. Maps were analyzed to characterize wave front propagation patterns in all atrial regions. The relationship between substrate and conduction was evaluated. A total of 42 right atrial macro-re-entrant circuits were observed. The most common location of the posterior line of block was the posteromedial right atrium (73%). This line of block continued superiorly into the superior vena cava, taking an oblique course to finish on the anterior superior vena cava aspect in 73%. Conduction delay at the crista terminalis was less common (23%). Conduction slowing or block was seen at the limbus of the fossa ovalis (73%) and Eustachian ridge (77%). Highly variable and localized areas of slow conduction were also observed in the inferior septum (45%), superior septum (27%), anterosuperior right atrium (23%), and lateral right atrium (23%). Localized conduction slowing was seen in the cavotricuspid isthmus in 50% of patients, but there was no generalized conduction slowing in this isthmus. The voltage in regions of slow conduction was significantly lower compared with areas of normal conduction velocity (p < 0.001). Conduction channels were observed in 55% of patients. High-resolution 3D mapping has provided new insights into the nature of right atrial macro-re-entrant tachycardias. Variable regions of abnormal atrial substrate were associated with conduction slowing and block. Individual variation in propagation patterns was observed in association with this variable substrate. (Mapping of Atrial Arrhythmias Using High Spatial Resolution Mapping Catheters and the Rhythmia Mapping System; ACTRN12615000544572). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Modeling Programs Increase Aircraft Design Safety

    NASA Technical Reports Server (NTRS)

    2012-01-01

    Flutter may sound like a benign word when associated with a flag in a breeze, a butterfly, or seaweed in an ocean current. When used in the context of aerodynamics, however, it describes a highly dangerous, potentially deadly condition. Consider the case of the Lockheed L-188 Electra Turboprop, an airliner that first took to the skies in 1957. Two years later, an Electra plummeted to the ground en route from Houston to Dallas. Within another year, a second Electra crashed. In both cases, all crew and passengers died. Lockheed engineers were at a loss as to why the planes wings were tearing off in midair. For an answer, the company turned to NASA s Transonic Dynamics Tunnel (TDT) at Langley Research Center. At the time, the newly renovated wind tunnel offered engineers the capability of testing aeroelastic qualities in aircraft flying at transonic speeds near or just below the speed of sound. (Aeroelasticity is the interaction between aerodynamic forces and the structural dynamics of an aircraft or other structure.) Through round-the-clock testing in the TDT, NASA and industry researchers discovered the cause: flutter. Flutter occurs when aerodynamic forces acting on a wing cause it to vibrate. As the aircraft moves faster, certain conditions can cause that vibration to multiply and feed off itself, building to greater amplitudes until the flutter causes severe damage or even the destruction of the aircraft. Flutter can impact other structures as well. Famous film footage of the Tacoma Narrows Bridge in Washington in 1940 shows the main span of the bridge collapsing after strong winds generated powerful flutter forces. In the Electra s case, faulty engine mounts allowed a type of flutter known as whirl flutter, generated by the spinning propellers, to transfer to the wings, causing them to vibrate violently enough to tear off. Thanks to the NASA testing, Lockheed was able to correct the Electra s design flaws that led to the flutter conditions and return the aircraft to safe flight. Today, all aircraft must have a flutter boundary 15 percent beyond the aircraft s expected maximum speed to ensure that flutter conditions are not encountered in flight. NASA continues to support research in new aircraft designs to improve knowledge of aeroelasticity and flutter. Through platforms such as Dryden Flight Research Center s Active Aeroelastic Wing (AAW) research aircraft, the Agency researches methods for in-flight validation of predictions and for controlling and taking advantage of aeroelastic conditions to enhance aircraft performance.

  14. Management of unstable arrhythmias in cardiogenic shock.

    PubMed

    Saidi, Abdulfattah; Akoum, Nazem; Bader, Feras

    2011-08-01

    Atrial and ventricular arrhythmias commonly arise in the setting of cardiogenic shock and often result in hemodynamic deterioration. Causative factors include myocardial ischemia, volume overload, and metabolic disturbances. Correcting these factors plays an important role in managing arrhythmias in this setting. Ventricular arrhythmias are more ominous compared to atrial arrhythmias but both require prompt intervention with electrical shock and anti-arrhythmic drug suppression. Coronary reperfusion is key to improving survival, including reducing the risk of sudden cardiac arrest, in acute myocardial infarction. Case series have also demonstrated the value of intra-aortic balloon pump counter-pulsation in suppressing ventricular arrhythmias in cardiogenic shock. The mechanism of arrhythmia suppression may be due to improved coronary perfusion and afterload reduction. Percutaneous ventricular assist device placement may be effective in this setting; however, data addressing this specific endpoint are lacking. Anti-arrhythmic drug options for ventricular and atrial arrhythmia suppression, in the setting of cardiogenic shock, are relatively limited. Common class I agents are excluded due to the inherent abnormal cardiac structure and function in the setting of cardiogenic shock. Class III drug options include dofetilide and amiodarone. The other Class III agents, sotalol and dronedarone, are excluded due to associated mortality observed in the SWORD and ANDROMEDA trials, respectively. Dofetilide is renally excreted and causes QT interval prolongation. Care should be taken to avoid excessive drug accumulation due to poor kidney perfusion and function. Dofetilide is approved for use for atrial arrhythmias and has not been studied for ventricular arrhythmia suppression. The DIAMOND-CHF trial established its safety in the setting of heart failure. Amiodarone is very effective in suppressing both atrial and ventricular arrhythmias. It is often the drug of choice in heart failure. Its off-label use for atrial arrhythmias is very common. Care should be taken with intravenous amiodarone to avoid hypotension.

  15. Subclinical atrial fibrillation and the risk of stroke.

    PubMed

    Healey, Jeff S; Connolly, Stuart J; Gold, Michael R; Israel, Carsten W; Van Gelder, Isabelle C; Capucci, Alessandro; Lau, C P; Fain, Eric; Yang, Sean; Bailleul, Christophe; Morillo, Carlos A; Carlson, Mark; Themeles, Ellison; Kaufman, Elizabeth S; Hohnloser, Stefan H

    2012-01-12

    One quarter of strokes are of unknown cause, and subclinical atrial fibrillation may be a common etiologic factor. Pacemakers can detect subclinical episodes of rapid atrial rate, which correlate with electrocardiographically documented atrial fibrillation. We evaluated whether subclinical episodes of rapid atrial rate detected by implanted devices were associated with an increased risk of ischemic stroke in patients who did not have other evidence of atrial fibrillation. We enrolled 2580 patients, 65 years of age or older, with hypertension and no history of atrial fibrillation, in whom a pacemaker or defibrillator had recently been implanted. We monitored the patients for 3 months to detect subclinical atrial tachyarrhythmias (episodes of atrial rate >190 beats per minute for more than 6 minutes) and followed them for a mean of 2.5 years for the primary outcome of ischemic stroke or systemic embolism. Patients with pacemakers were randomly assigned to receive or not to receive continuous atrial overdrive pacing. By 3 months, subclinical atrial tachyarrhythmias detected by implanted devices had occurred in 261 patients (10.1%). Subclinical atrial tachyarrhythmias were associated with an increased risk of clinical atrial fibrillation (hazard ratio, 5.56; 95% confidence interval [CI], 3.78 to 8.17; P<0.001) and of ischemic stroke or systemic embolism (hazard ratio, 2.49; 95% CI, 1.28 to 4.85; P=0.007). Of 51 patients who had a primary outcome event, 11 had had subclinical atrial tachyarrhythmias detected by 3 months, and none had had clinical atrial fibrillation by 3 months. The population attributable risk of stroke or systemic embolism associated with subclinical atrial tachyarrhythmias was 13%. Subclinical atrial tachyarrhythmias remained predictive of the primary outcome after adjustment for predictors of stroke (hazard ratio, 2.50; 95% CI, 1.28 to 4.89; P=0.008). Continuous atrial overdrive pacing did not prevent atrial fibrillation. Subclinical atrial tachyarrhythmias, without clinical atrial fibrillation, occurred frequently in patients with pacemakers and were associated with a significantly increased risk of ischemic stroke or systemic embolism. (Funded by St. Jude Medical; ASSERT ClinicalTrials.gov number, NCT00256152.).

  16. Flight Flutter Testing of Supersonic Interceptors

    NASA Technical Reports Server (NTRS)

    Dublin, M.; Peller, R.

    1975-01-01

    A summary is presented of experiences in connection with flight flutter testing of supersonic interceptors. The planning and operational aspects involved are described along with the difficulties encountered, and the correlation between measurement and theory. Recommendations for future research and development to advance the science of flight flutter testing are included.

  17. NASTRAN documentation for flutter analysis of advanced turbopropellers

    NASA Technical Reports Server (NTRS)

    Elchuri, V.; Gallo, A. M.; Skalski, S. C.

    1982-01-01

    An existing capability developed to conduct modal flutter analysis of tuned bladed-shrouded discs was modified to facilitate investigation of the subsonic unstalled flutter characteristics of advanced turbopropellers. The modifications pertain to the inclusion of oscillatory modal aerodynamic loads of blades with large (backward and forward) varying sweep.

  18. Flutter suppression via piezoelectric actuation

    NASA Technical Reports Server (NTRS)

    Heeg, Jennifer

    1991-01-01

    Experimental flutter results obtained from wind tunnel tests of a two degree of freedom wind tunnel model are presented for the open and closed loop systems. The wind tunnel model is a two degree of freedom system which is actuated by piezoelectric plates configured as bimorphs. The model design was based on finite element structural analyses and flutter analyses. A control law was designed based on a discrete system model; gain feedback of strain measurements was utilized in the control task. The results show a 21 pct. increase in the flutter speed.

  19. Experimental transonic flutter characteristics of two 72 deg-sweep delta-wing models

    NASA Technical Reports Server (NTRS)

    Doggett, Robert V., Jr.; Soistmann, David L.; Spain, Charles V.; Parker, Ellen C.; Silva, Walter A.

    1989-01-01

    Transonic flutter boundaries are presented for two simple, 72 deg. sweep, low-aspect-ratio wing models. One model was an aspect-ratio 0.65 delta wing; the other model was an aspect-ratio 0.54 clipped-delta wing. Flutter boundaries for the delta wing are presented for the Mach number range of 0.56 to 1.22. Flutter boundaries for the clipped-delta wing are presented for the Mach number range of 0.72 to 0.95. Selected vibration characteristics of the models are also presented.

  20. Wind-tunnel evaluation of NASA developed control laws for flutter suppression on a DC-10 derivative wing

    NASA Technical Reports Server (NTRS)

    Abel, I.; Newsom, J. R.

    1981-01-01

    Two flutter suppression control laws were synthesized, implemented, and tested on a low speed aeroelastic wing model of a DC-10 derivative. The methodology used to design the control laws is described. Both control laws demonstrated increases in flutter speed in excess of 25 percent above the passive wing flutter speed. The effect of variations in gain and phase on the closed loop performance was measured and compared with analytical predictions. The analytical results are in good agreement with experimental data.

  1. Worst-Case Flutter Margins from F/A-18 Aircraft Aeroelastic Data

    NASA Technical Reports Server (NTRS)

    Lind, Rick; Brenner, Marty

    1997-01-01

    An approach for computing worst-case flutter margins has been formulated in a robust stability framework. Uncertainty operators are included with a linear model to describe modeling errors and flight variations. The structured singular value, micron, computes a stability margin which directly accounts for these uncertainties. This approach introduces a new method of computing flutter margins and an associated new parameter for describing these margins. The micron margins are robust margins which indicate worst-case stability estimates with respect to the defined uncertainty. Worst-case flutter margins are computed for the F/A-18 SRA using uncertainty sets generated by flight data analysis. The robust margins demonstrate flight conditions for flutter may lie closer to the flight envelope than previously estimated by p-k analysis.

  2. Flutter analysis of composite box beams

    NASA Technical Reports Server (NTRS)

    Hodges, Dewey H.; Greenman, Matthew

    1995-01-01

    The dynamic aeroelastic instability of flutter is an important factor in the design of modern high-speed, flexible aircraft. The current trend is toward the creative use of composites to delay flutter. To obtain an optimum design, we need an accurate as well as efficient model. As a first step towards this goal, flutter analysis is carried out for an unswept composite box beam using a linear structural model and Theodorsen's unsteady aerodynamic theory. Structurally, the wing was modeled as a thin-walled box-beam of rectangular cross section. Theodorsen's theory was used to get 2-D unsteady aerodynamic forces, which were integrated over the span. A free-vibration analysis is carried out. These fundamental modes are used to get the flutter solution using the V-g method. Future work is intended to build on this foundation.

  3. Free-Spinning-Tunnel Investigation of a 1/20-Scale Model of an Unswept-Wing Jet-Propelled Trainer Airplane

    NASA Technical Reports Server (NTRS)

    Bowman, James S., Jr.; Healy, Frederick M.

    1960-01-01

    A flutter analysis employing the kernel function for three- dimensional, subsonic, compressible flow is applied to a flutter-tested tail surface which has an aspect ratio of 3.5, a taper ratio of 0.15, and a leading-edge sweep of 30 deg. Theoretical and experimental results are compared at Mach numbers from 0.75 to 0.98. Good agreement between theoretical and experimental flutter dynamic pressures and frequencies is achieved at Mach numbers to 0.92. At Mach numbers from 0.92 to 0.98, however, a second solution to the flutter determinant results in a spurious theoretical flutter boundary which is at a much lower dynamic pressure and at a much higher frequency than the experimental boundary.

  4. Flutter Analysis of the Shuttle Tile Overlay Repair Concept

    NASA Technical Reports Server (NTRS)

    Bey, Kim S.; Scott, Robert C.; Bartels, Robert E.; Waters, William A.; Chen, Roger

    2007-01-01

    The Space Shuttle tile overlay repair concept, developed at the NASA Johnson Space Center, is designed for on-orbit installation over an area of damaged tile to permit safe re-entry. The thin flexible plate is placed over the damaged area and secured to tile at discreet points around its perimeter. A series of flutter analyses were performed to determine if the onset of flutter met the required safety margins. Normal vibration modes of the panel, obtained from a simplified structural analysis of the installed concept, were combined with a series of aerodynamic analyses of increasing levels of fidelity in terms of modeling the flow physics to determine the onset of flutter. Results from these analyses indicate that it is unlikely that the overlay installed at body point 1800 will flutter during re-entry.

  5. Analytical and experimental study of the effects of wing-body aerodynamic interaction on space shuttle subsonic flutter

    NASA Technical Reports Server (NTRS)

    Chipman, R. R.; Rauch, F. J.

    1975-01-01

    The effects on flutter of the aerodynamic interaction between the space shuttle bodies and wing, 1/80th-scale semispan models of the orbiter wing, the complete shuttle and intermediate component combinations were tested in the NASA Langley Research Center 26-inch Transonic Blowdown Wind Tunnel. Using the double lattice method combined with slender body theory to calculate unsteady aerodynamic forces, subsonic flutter speeds were computed for comparison. Using calculated complete vehicle modes, flutter speed trends were computed for the full scale vehicle at an altitude of 15,200 meters and a Mach number of 0.6. Consistent with findings of the model studies, analysis shows the shuttle to have the same flutter speed as an isolated cantilevered wing.

  6. Flutter suppression of plates using passive constrained viscoelastic layers

    NASA Astrophysics Data System (ADS)

    Cunha-Filho, A. G.; de Lima, A. M. G.; Donadon, M. V.; Leão, L. S.

    2016-10-01

    Flutter in aeronautical panels is a self-excited aeroelastic phenomenon which occurs during supersonic flights due to dynamic instability of inertia, elastic and aerodynamic forces of the system. In the flutter condition, when the critical aerodynamic pressure is reached, the vibration amplitudes of the panel become dynamically unstable and increase exponentially with time, significantly affecting the fatigue life of the existing aeronautical components. Thus, in this paper, the interest is to investigate the possibility reducing the effects of the supersonic aeroelastic instability of rectangular plates by applying passive constrained viscoelastic layers. The rationale for such study is the fact that as the addition of viscoelastic materials provides decreased vibration amplitudes it becomes important to quantify the suppression of plate flutter coalescence modes that can be obtained. Moreover, despite the fact that much research on the suppression of panel flutter has been carried out by using passive, semi-active and active control techniques, few works have been proposed to deal with the problem of predicting the flutter boundary of aeroviscoelastic systems, since they must conveniently account for the frequency- and temperature-dependent behavior of the viscoelastic material. After the presentation of the theoretical foundations of the methodology, the description of a numerical study on the flutter analysis of a three-layer sandwich plate is addressed.

  7. Planform curvature effects on flutter characteristics of a wing with 56 deg leading-edge sweep and panel aspect ratio of 1.14

    NASA Technical Reports Server (NTRS)

    Keller, Donald F.; Sandford, Maynard C.; Pinkerton, Theresa L.

    1991-01-01

    An experimental and analytical investigation was initiated to determine the effects of planform curvature (curving the leading and trailing edges of a wing in the X-Y plane) on the transonic flutter characteristics of a series of three moderately swept wing models. Experimental flutter results were obtained in the Langley Transonic Dynamics Tunnel for Mach numbers from 0.60-1.00, with air as the test medium. The models were semispan cantilevered wings with a 3 percent biconvex airfoil and a panel aspect ratio of 1.14. The baseline model had straight leading and trailing edges (i.e., no planform curvature). The radii of curvature of the leading edges for these two models were 200 and 80 inches. The radii of curvature of the leading edges of the other two models were determined so that the root and tip chords were identical for all three models. Experimental results showed that flutter-speed index and flutter frequency ratio increased as planform curvature increase (radius of curvature of the leading edge was decreased) over the test range of Mach numbers. Analytical flutter results were calculated with a subsonic flutter-prediction program, and they agreed well with the experimental results.

  8. Test Characteristics of Neck Fullness and Witnessed Neck Pulsations in the Diagnosis of Typical AV Nodal Reentrant Tachycardia

    PubMed Central

    Sakhuja, Rahul; Smith, Lisa M; Tseng, Zian H; Badhwar, Nitish; Lee, Byron K; Lee, Randall J; Scheinman, Melvin M; Olgin, Jeffrey E; Marcus, Gregory M

    2011-01-01

    Summary Background Claims in the medical literature suggest that neck fullness and witnessed neck pulsations are useful in the diagnosis of typical AV nodal reentrant tachycardia (AVNRT). Hypothesis Neck fullness and witnessed neck pulsations have a high positive predictive value in the diagnosis of typical AVNRT. Methods We performed a cross sectional study of consecutive patients with palpitations presenting to a single electrophysiology (EP) laboratory over a 1 year period. Each patient underwent a standard questionnaire regarding neck fullness and/or witnessed neck pulsations during their palpitations. The reference standard for diagnosis was determined by electrocardiogram and invasive EP studies. Results Comparing typical AVNRT to atrial fibrillation (AF) or atrial flutter (AFL) patients, the proportions with neck fullness and witnessed neck pulsations did not significantly differ: in the best case scenario (using the upper end of the 95% confidence interval [CI]), none of the positive or negative predictive values exceeded 79%. After restricting the population to those with supraventricular tachycardia other than AF or AFL (SVT), neck fullness again exhibited poor test characteristics; however, witnessed neck pulsations exhibited a specificity of 97% (95% CI 90–100%) and a positive predictive value of 83% (95% CI 52–98%). After adjustment for potential confounders, SVT patients with witnessed neck pulsations had a 7 fold greater odds of having typical AVNRT, p=0.029. Conclusions Although neither neck fullness nor witnessed neck pulsations are useful in distinguishing typical AVNRT from AF or AFL, witnessed neck pulsations are specific for the presence of typical AVNRT among those with SVT. PMID:19479968

  9. A structured reading algorithm improves telemetric detection of atrial fibrillation after acute ischemic stroke.

    PubMed

    Kallmünzer, Bernd; Breuer, Lorenz; Hering, Christiane; Raaz-Schrauder, Dorette; Kollmar, Rainer; Huttner, Hagen B; Schwab, Stefan; Köhrmann, Martin

    2012-04-01

    Anticoagulation is a highly effective secondary prevention in patients with cardioembolic stroke and atrial fibrillation/flutter (AF). However, the condition remains underdiagnosed, because paroxysmal AF may be missed by diagnostic tests in the acute phase. In this study, the sensitivity of AF detection was assessed for serial electrocardiographic recordings and continuous stroke unit telemetric monitoring with or without a structured algorithm to analyze telemetric data (SEA-AF). Three hundred forty-six consecutive patients with acute ischemic stroke were prospectively included and subjected to standard telemetric monitoring. In addition, telemetric data were separately analyzed following SEA-AF, consisting of a structured evaluation of episodes with high risk for AF and a chronological beat-to-beat screening of the full registration. Serial electrocardiograms were conducted in 24-hour intervals. Median effective telemetry monitoring time was 75.5 hours (interquartile range 64-86 hours). Overall, AF was diagnosed in 119 of 346 patients (34.4%). The structured reading algorithm was the most sensitive method to detected AF. Conventional telemetry and serial electrocardiographic assessments were less effective. However, only 35% of patients with previously documented paroxysmal AF and negative baseline electrocardiogram demonstrated AF episodes during monitoring. Continuous stroke unit telemetry using SEA-AF shows a significantly higher detection rate for AF compared with daily electrocardiographic assessments and standard telemetry without structured reading. The low overall probability to detect paroxysmal AF with either method during the first days after stroke demonstrates the urgent need for complementary diagnostic strategies such as long-term monitoring and frequent follow-up assessments. Clinical Trial Registration- URL: www.clinicaltrials.gov. Unique identifier: NCT01177748.

  10. Comparison of Temporal Parameters of Swimming Rescue Elements When Performed Using Dolphin and Flutter Kick with Fins - Didactical Approach

    PubMed Central

    Rejman, Marek; Wiesner, Wojciech; Silakiewicz, Piotr; Klarowicz, Andrzej; Abraldes, J. Arturo

    2012-01-01

    The aim of this study was an analysis of the time required to swim to a victim and tow them back to shore, while perfoming the flutter-kick and the dolphin-kick using fins. It has been hypothesized that using fins while using the dolphin-kick when swimming leads to reduced rescue time. Sixteen lifeguards took part in the study. The main tasks performed by them, were to approach and tow (double armpit) a dummy a distance of 50m while applying either the flutter-kick, or the dolphin-kick with fins. The analysis of the temporal parameters of both techniques of kicking demonstrates that, during the approach to the victim, neither the dolphin (tmean = 32.9s) or the flutter kick (tmean = 33.0s) were significantly faster than the other. However, when used for towing a victim the flutter kick (tmean = 47.1s) was significantly faster when compared to the dolphin-kick (tmean = 52.8s). An assessment of the level of technical skills in competitive swimming, and in approaching and towing the victim, were also conducted. Towing time was significantly correlated with the parameter that linked the temporal and technical dimensions of towing and swimming (difference between flutter kick towing time and dolphin-kick towing time, 100m medley time and the four swimming strokes evaluation). No similar interdependency has been discovered in flutter kick towing time. These findings suggest that the dolphin-kick is a more difficult skill to perform when towing the victim than the flutter-kick. Since the hypothesis stated was not confirmed, postulates were formulated on how to improve dolphin-kick technique with fins, in order to reduce swimming rescue time. Key points The source of reduction of swimming rescue time was researched. Time required to approach and to tow the victim while doing the flutter kick and the dolphin-kick with fins was analyzed. The propulsion generated by dolphin-kick did not make the approach and tow faster than the flutter kick. More difficult skill to realize of dolphin-kick than the flutter-kick was postulated. The criteria for how improve dolphin kick technique with fins were formulated. PMID:24150079

  11. Fish Oil and Post-Operative Atrial Fibrillation – Results of the Omega-3 Fatty Acids for Prevention of Post-Operative Atrial Fibrillation (OPERA) Trial

    PubMed Central

    Mozaffarian, Dariush; Marchioli, Roberto; Macchia, Alejandro; Silletta, Maria G.; Ferrazzi, Paolo; Gardner, Timothy J.; Latini, Roberto; Libby, Peter; Lombardi, Federico; O’Gara, Patrick T.; Page, Richard L.; Tavazzi, Luigi; Tognoni, Gianni

    2013-01-01

    Context Post-operative atrial fibrillation/flutter (AF) is one of the most common complications of cardiac surgery and significantly increases morbidity and healthcare utilization. A few small trials have evaluated whether long-chain n-3-polyunsaturated fatty acids (PUFA) reduce post-op AF, with mixed results. Objective To determine whether peri-operative n-3-PUFA supplementation reduces post-op AF. Design Randomized, double-blind, placebo-controlled, multinational, clinical trial. Patients A total of 1,516 patients scheduled for cardiac surgery across 28 centers in the US, Italy, and Argentina, enrolled between Aug 2010 and Jun 2012. Inclusion criteria were broad; the main exclusions were regular use of fish oil or absence of sinus rhythm at enrollment. Forty-eight percent of screened patients and 94% of eligible patients were enrolled. Intervention Patients were randomized to receive fish oil (1 g capsules containing ≥840 mg n-3-PUFA as ethyl esters) or placebo, with pre-operative loading of 10g over 3-5 days (or 8g over 2 days) followed post-operatively by 2g/d until hospital discharge or post-op day10, whichever first. Main Outcome Measures The primary endpoint was occurrence of post-op AF >30 sec. We also evaluated post-op AF lasting >1hr, resulting in symptoms, or treated with cardioversion; other secondary post-op AF endpoints; other tachyarrhythmias; hospital utilization; and major adverse cardiovascular events, 30-day mortality, bleeding, and other adverse events. All endpoints and analyses plans were prespecified. Results At enrollment, mean±SD age was 64±13 years, 72.2% were male, and 51.8% had planned valvular surgery. The primary endpoint occurred in 233 (30.7%) and 227 (30.0%) patients assigned to placebo and n-3-PUFA, respectively (OR=0.96, 95%CI=0.77-1.20; P=0.74). None of the secondary endpoints were significantly different, including post-op AF that was sustained, symptomatic, or treated (n=231 [30.5%] vs. n=224 [29.6%], P=0.70) or number of post-op AF episodes per patient (1 episode: n=220 [29.0%] vs. n=217 [28.6%]; 2 episodes: n=156 [20.6%] vs. n=157 [20.7%]; 3+ episodes: n=18 [2.4%] vs. n=21 [2.8%]; P=0.73). n-3-PUFA was generally well-tolerated, with no evidence for increased risk of bleeding or serious adverse events. Conclusions In this large multinational trial among patients undergoing cardiac surgery, peri-operative supplementation with n-3-PUFA, compared to placebo, did not reduce the risk of post-operative AF. PMID:23128104

  12. Clinical Features and Surgical Results of Right Atrial Myxoma.

    PubMed

    Li, Han; Guo, Hongwei; Xiong, Hui; Xu, Jianping; Wang, Wei; Hu, Shengshou

    2016-01-01

    We retrospectively analyzed 367 patients receiving surgical resection of cardiac myxomas in our center over six years, and analyzed the incidence and surgical results of 28 cases of right atrial myxomas. We also compared the age, gender, and attached sites between left atrial myxoma and right atrial myxoma. Between January 2007 and December 2012, 28 patients with right atrial myxomas underwent surgical resection. There were 16 males and 12 females. The mean age was 47.77 ± 13.20 years (range: 8.00-79.00 years). Associated cardiac lesions included moderate and severe tricuspid regurgitation in four, coronary atherosclerotic heart disease in five, and pulmonary embolism in one. Twenty-seven patients (96.43%) were followed from 26 to 94 months (mean 55.78 ± 21.10 months). There was no early death after operation. The incidence of right atrial myxomas among sporadic cardiac myxomas was 7.89%. One patient died of lung cancer 34 months after myxoma resection. Two patients underwent coronary artery stent implantation due to coronary atherosclerotic heart disease during the follow-up period. One patient underwent myxoma resection due to recurrence in the left atrium four years after the first operation. There was no significant difference in the age between left atrial myxoma and right atrial myxoma (p > 0.05). There was a significant difference in the gender between left atrial myxomas and right atrial myxomas (p < 0.05). The most common attached sites of left atrial myxomas and right atrial myxomas are the atrial septum. Surgical resection of the right atrial myxoma results in good clinical outcomes and a decreased incidence of recurrence. © 2015 Wiley Periodicals, Inc.

  13. Supersonic Stall Flutter of High Speed Fans. [in turbofan engines

    NASA Technical Reports Server (NTRS)

    Adamczyk, J. J.; Stevens, W.; Jutras, R.

    1981-01-01

    An analytical model is developed for predicting the onset of supersonic stall bending flutter in axial flow compressors. The analysis is based on a modified two dimensional, compressible, unsteady actuator disk theory. It is applied to a rotor blade row by considering a cascade of airfoils whose geometry and dynamic response coincide with those of a rotor blade element at 85 percent of the span height (measured from the hub). The rotor blades are assumed to be unshrouded (i.e., free standing) and to vibrate in their first flexural mode. The effects of shock waves and flow separation are included in the model through quasi-steady, empirical, rotor total-pressure-loss and deviation-angle correlations. The actuator disk model predicts the unsteady aerodynamic force acting on the cascade blading as a function of the steady flow field entering the cascade and the geometry and dynamic response of the cascade. Calculations show that the present model predicts the existence of a bending flutter mode at supersonic inlet Mach numbers. This flutter mode is suppressed by increasing the reduced frequency of the system or by reducing the steady state aerodynamic loading on the cascade. The validity of the model for predicting flutter is demonstrated by correlating the measured flutter boundary of a high speed fan stage with its predicted boundary. This correlation uses a level of damping for the blade row (i.e., the log decrement of the rotor system) that is estimated from the experimental flutter data. The predicted flutter boundary is shown to be in good agreement with the measured boundary.

  14. Experimental Investigation at Mach Number 3.0 of the Effects of Thermal Stress and Buckling on the Flutter of Four-Bay Aluminum Alloy Panels with Length-Width Ratios of 10

    NASA Technical Reports Server (NTRS)

    Dixon, Sidney C.; Griffith, George E.; Bohon, Herman L.

    1961-01-01

    Skin-stiffener aluminum alloy panels consisting of four bays, each bay having a length-width ratio of 10, were tested at a Mach number of 3.0 at dynamic pressures ranging from 1,500 psf to 5,000 psf and at stagnation temperatures from 300 F to 655 F. The panels were restrained by the supporting structure in such a manner that partial thermal expansion of the skins could occur in both the longitudinal and lateral directions. A boundary faired through the experimental flutter points consisted of a flat-panel portion, a buckled-panel portion, and a transition point at the intersection of the two boundaries. In the region where a panel must be flat when flutter occurs, an increase in panel skin temperature (or midplane compressive stress) makes the panel more susceptible to flutter. In the region where a panel must be buckled when flutter occurs, the flutter trend is reversed. This reversal in trend is attributed to the panel postbuckling behavior.

  15. Bayesian analysis of the flutter margin method in aeroelasticity

    DOE PAGES

    Khalil, Mohammad; Poirel, Dominique; Sarkar, Abhijit

    2016-08-27

    A Bayesian statistical framework is presented for Zimmerman and Weissenburger flutter margin method which considers the uncertainties in aeroelastic modal parameters. The proposed methodology overcomes the limitations of the previously developed least-square based estimation technique which relies on the Gaussian approximation of the flutter margin probability density function (pdf). Using the measured free-decay responses at subcritical (preflutter) airspeeds, the joint non-Gaussain posterior pdf of the modal parameters is sampled using the Metropolis–Hastings (MH) Markov chain Monte Carlo (MCMC) algorithm. The posterior MCMC samples of the modal parameters are then used to obtain the flutter margin pdfs and finally the fluttermore » speed pdf. The usefulness of the Bayesian flutter margin method is demonstrated using synthetic data generated from a two-degree-of-freedom pitch-plunge aeroelastic model. The robustness of the statistical framework is demonstrated using different sets of measurement data. In conclusion, it will be shown that the probabilistic (Bayesian) approach reduces the number of test points required in providing a flutter speed estimate for a given accuracy and precision.« less

  16. Flutter performance of bend-twist coupled large-scale wind turbine blades

    NASA Astrophysics Data System (ADS)

    Hayat, Khazar; de Lecea, Alvaro Gorostidi Martinez; Moriones, Carlos Donazar; Ha, Sung Kyu

    2016-05-01

    The bend-twist coupling (BTC) is proven to be effective in mitigating the fatigue loads for large-scale wind turbine blades, but at the same time it may cause the risk of flutter instability. The BTC is defined as a feature of twisting of the blade induced by the primary bending deformation. In the classical flutter, the BTC arises from the aerodynamic loads changing with the angle of attack. In this study, the effects of the structural BTC on the flutter are investigated by considering the layup unbalances (ply angle, material and thickness of the composite laminates) in the NREL 5-MW wind turbine rotor blade of glass fiber/epoxy [02/+45/-45]S laminates. It is numerically shown that the flutter speed may decrease by about 5 percent with unbalanced ply-angle only (one side angle, from 45° to 25°). It was then demonstrated that the flutter performance of the wind turbine blade can be increased by using lighter and stiffer carbon fibers which ensures the higher structural BTC at the same time.

  17. Long-term biatrial recordings in post-operative atrial fibrillation.

    PubMed

    Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F

    2010-01-01

    Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.

  18. High duty cycle echolocation and prey detection by bats.

    PubMed

    Lazure, Louis; Fenton, M Brock

    2011-04-01

    There are two very different approaches to laryngeal echolocation in bats. Although most bats separate pulse and echo in time by signalling at low duty cycles (LDCs), almost 20% of species produce calls at high duty cycles (HDCs) and separate pulse and echo in frequency. HDC echolocators are sensitive to Doppler shifts. HDC echolocation is well suited to detecting fluttering targets such as flying insects against a cluttered background. We used two complementary experiments to evaluate the relative effectiveness of LDC and HDC echolocation for detecting fluttering prey. We measured echoes from fluttering targets by broadcasting artificial bat calls, and found that echo amplitude was greatest for sounds similar to those used in HDC echolocation. We also collected field recordings of syntopic LDC and HDC bats approaching an insect-like fluttering target and found that HDC bats approached the target more often (18.6% of passes) than LDC bats (1.2% of passes). Our results suggest that some echolocation call characteristics, particularly duty cycle and pulse duration, translate into improved ability to detect fluttering targets in clutter, and that HDC echolocation confers a superior ability to detect fluttering prey in the forest understory compared with LDC echolocation. The prevalence of moths in the diets of HDC bats, which is often used as support for the allotonic frequency hypothesis, can therefore be partly explained by the better flutter detection ability of HDC bats.

  19. Apixaban to prevent stroke in patients with atrial fibrillation: a review

    PubMed Central

    Peterson, Benjamin E.; Al-Khatib, Sana M.; Granger, Christopher B.

    2016-01-01

    Atrial fibrillation is a common, costly and morbid cardiovascular arrhythmia. Stroke prevention remains the mainstay of treatment for atrial fibrillation, and the recent advent of novel oral anticoagulants with direct factor IIa or factor Xa inhibition has significantly revolutionized this aspect of treatment for atrial fibrillation patients. This review focuses on the tolerability and efficacy of apixaban and tackles the generalizability of the findings with apixaban to broader patient populations than those primarily enrolled in the clinical trials, drawing from the AVERROES and ARISTOTLE trials and their subsequent secondary analyses. Taken together, findings from these trials show that apixaban is superior to warfarin in preventing stroke with a lower risk of major bleeding in the general population of patients with atrial fibrillation as well as in several key high-risk patient subgroups. PMID:27342651

  20. Test Cases for Flutter of the Benchmark Models Rectangular Wings on the Pitch and Plunge Apparatus

    NASA Technical Reports Server (NTRS)

    Bennett, Robert M.

    2000-01-01

    The supercritical airfoil was chosen as a relatively modem airfoil for comparison. The BOO12 model was tested first. Three different types of flutter instability boundaries were encountered, a classical flutter boundary, a transonic stall flutter boundary at angle of attack, and a plunge instability near M = 0.9 and for zero angle of attack. This test was made in air and was Transonic Dynamics Tunnel (TDT) Test 468. The BSCW model (for Benchmark SuperCritical Wing) was tested next as TDT Test 470. It was tested using both with air and a heavy gas, R-12, as a test medium. The effect of a transition strip on flutter was evaluated in air. The B64AOlO model was subsequently tested as TDT Test 493. Some further analysis of the experimental data for the BOO12 wing is presented. Transonic calculations using the parameters for the BOO12 wing in a two-dimensional typical section flutter analysis are given. These data are supplemented with data from the Benchmark Active Controls Technology model (BACT) given and in the next chapter of this document. The BACT model was of the same planform and airfoil as the BOO12 model, but with spoilers and a trailing edge control. It was tested in the heavy gas R-12, and was instrumented mostly at the 60 per cent span. The flutter data obtained on PAPA and the static aerodynamic test cases from BACT serve as additional data for the BOO12 model. All three types of flutter are included in the BACT Test Cases. In this report several test cases are selected to illustrate trends for a variety of different conditions with emphasis on transonic flutter. Cases are selected for classical and stall flutter for the BSCW model, for classical and plunge for the B64AOlO model, and for classical flutter for the BOO12 model. Test Cases are also presented for BSCW for static angles of attack. Only the mean pressures and the real and imaginary parts of the first harmonic of the pressures are included in the data for the test cases, but digitized time histories have been archived. The data for the test cases are available as separate electronic files. An overview of the model and tests is given, the standard formulary for these data is listed, and some sample results are presented.

  1. Subsonic and Supersonic Flutter Analysis of a Highly Tapered Swept-Wing Planform, Including Effects of Density Variation and Finite Wing Thickness, and Comparison with Experiments

    NASA Technical Reports Server (NTRS)

    Yates, Carson, Jr.

    1967-01-01

    The flutter characteristics of several wings with an aspect-ratio of 4.0, a taper ratio of 0.2, and a quarter-chord sweepback of 45 deg. have been investigated analytically for Mach numbers up to 2.0. The calculations were based on the modified-strip-analysis method, the subsonic-kernel-function method, piston theory, and quasi-steady second-order theory. Results of t h e analysis and comparisons with experiment indicated that: (1) Flutter speeds were accurately predicted by the modified strip analysis, although accuracy at t h e highest Mach numbers required the use of nonlinear aerodynamic theory (which accounts for effects of wing thickness) for the calculation of the aerodynamic parameters. (2) An abrupt increase of flutter-speed coefficient with increasing Mach number, observed experimentally in the transonic range, was also indicated by the modified strip analysis. (3) In the low supersonic range for some densities, a discontinuous variation of flutter frequency with Mach number was indicated by the modified strip analysis. An abrupt change of frequency appeared experimentally in the transonic range. (4) Differences in flutter-speed-coefficient levels obtained from tests at low supersonic Mach numbers in two wind tunnels were also predicted by the modified strip analysis and were shown to be caused primarily by differences in mass ratio. (5) Flutter speeds calculated by the subsonic-kernel-function method were in good agreement with experiment and with the results of the modified strip analysis. (6) Flutter speed obtained from piston theory and from quasi-steady second-order theory were higher than experimental values by at least 38 percent.

  2. Flutter-driven triboelectrification for harvesting wind energy

    NASA Astrophysics Data System (ADS)

    Bae, Jihyun; Lee, Jeongsu; Kim, Seongmin; Ha, Jaewook; Lee, Byoung-Sun; Park, Youngjun; Choong, Chweelin; Kim, Jin-Baek; Wang, Zhong Lin; Kim, Ho-Young; Park, Jong-Jin; Chung, U.-In

    2014-09-01

    Technologies to harvest electrical energy from wind have vast potentials because wind is one of the cleanest and most sustainable energy sources that nature provides. Here we propose a flutter-driven triboelectric generator that uses contact electrification caused by the self-sustained oscillation of flags. We study the coupled interaction between a fluttering flexible flag and a rigid plate. In doing so, we find three distinct contact modes: single, double and chaotic. The flutter-driven triboelectric generator having small dimensions of 7.5 × 5 cm at wind speed of 15 ms-1 exhibits high-electrical performances: an instantaneous output voltage of 200 V and a current of 60 μA with a high frequency of 158 Hz, giving an average power density of approximately 0.86 mW. The flutter-driven triboelectric generation is a promising technology to drive electric devices in the outdoor environments in a sustainable manner.

  3. Investigations on precursor measures for aeroelastic flutter

    NASA Astrophysics Data System (ADS)

    Venkatramani, J.; Sarkar, Sunetra; Gupta, Sayan

    2018-04-01

    Wind tunnel experiments carried out on a pitch-plunge aeroelastic system in the presence of fluctuating flows reveal that flutter instability is presaged by a regime of intermittency. It is observed that as the flow speed gradually increases towards the flutter speed, there appears intermittent bursts of periodic oscillations which become more frequent as the wind speed increases and eventually the dynamics transition into fully developed limit cycle oscillations, marking the onset of flutter. The signature from these intermittent oscillations are exploited to develop measures that forewarn a transition to flutter and can serve as precursors. This study investigates a suite of measures that are obtained directly from the time history of measurements and are hence model independent. The dependence of these precursors on the size of the measured data set and the time required for their computation is investigated. These measures can be useful in structural health monitoring of aeroelastic structures.

  4. Flutter suppression by active control and its benefits

    NASA Technical Reports Server (NTRS)

    Doggett, R. V., Jr.; Townsend, J. C.

    1976-01-01

    A general discussion of the airplane applications of active flutter suppression systems is presented with focus on supersonic cruise aircraft configurations. Topics addressed include a brief historical review; benefits, risks, and concerns; methods of application; and applicable configurations. Results are presented where the direct operating costs and performance benefits of an arrow wing supersonic cruise vehicle equipped with an active flutter suppression system are compared with corresponding costs and performance of the same baseline airplane where the flutter deficiency was corrected by passive methods (increases in structural stiffness). The design, synthesis, and conceptual mechanization of the active flutter suppression system are discussed. The results show that a substantial weight savings can be accomplished by using the active system. For the same payload and range, airplane direct operating costs are reduced by using the active system. The results also indicate that the weight savings translates into increased range or payload.

  5. Mechanism of Flutter A Theoretical and Experimental Investigation of the Flutter Problem

    NASA Technical Reports Server (NTRS)

    Theodorsen, Theodore; Garrick, I E

    1940-01-01

    The results of the basic flutter theory originally devised in 1934 and published as NACA Technical Report no. 496 are presented in a simpler and more complete form convenient for further studies. The paper attempts to facilitate the judgement of flutter problems by a systematic survey of the theoretical effects of the various parameters. A large number of experiments were conducted on cantilever wings, with and without ailerons, in the NACA high-speed wind tunnel for the purpose of verifying the theory and to study its adaptability to three-dimensional problems. The experiments included studies on wing taper ratios, nacelles, attached floats, and external bracings. The essential effects in the transition to the three-dimensional problem have been established. Of particular interest is the existence of specific flutter modes as distinguished from ordinary vibration modes. It is shown that there exists a remarkable agreement between theoretical and experimental results.

  6. A KCNQ1 Mutation Causes a High Penetrance for Familial Atrial Fibrillation

    PubMed Central

    Bartos, Daniel C.; Anderson, Jeffrey B.; Bastiaenen, Rachel; Johnson, Jonathan N.; Gollob, Michael H; Tester, David J.; Burgess, Don E.; Homfray, Tessa; Behr, Elijah R.; Ackerman, Michael J.; Guicheney, Pascale; Delisle, Brian P.

    2012-01-01

    Background Atrial fibrillation (AF) is the most common cardiac arrhythmia, and its incidence is expected to grow. A genetic predisposition for AF has long been recognized, but its manifestation in these patients likely involves a combination of rare and common genetic variants. Identifying genetic variants that associate with a high penetrance for AF would represent a significant breakthrough for understanding the mechanisms that associate with disease. Method and Results Candidate gene sequencing in five unrelated families with familial AF identified the KCNQ1 missense mutation p.Arg231His (R231H). In addition to AF, several of the family members have abnormal QTc intervals, syncope, or experienced sudden cardiac arrest or death. KCNQ1 encodes the voltage-gated K+ channel that conducts the slowly activating delayed rectifier K+ current in the heart. Functional and computational analyses suggested that R231H increases KCNQ1 current (IKCNQ1) to shorten the atrial action potential (AP) duration. R231H is predicted to minimally affect ventricular excitability, but it prevented the increase in IKCNQ1 following PKA activation. The unique properties of R231H appeared to be caused by a loss in voltage-dependent gating. Conclusions The R231H variant causes a high penetrance for interfamilial early-onset AF. Our study indicates R231H likely shortens atrial refractoriness to promote a substrate for reentry. Additionally, R231H might cause abnormal ventricular repolarization by disrupting PKA activation of IKCNQ1. We conclude genetic variants, which increase IKs during the atrial AP, decrease the atrial AP duration, and/or shorten atrial refractoriness, present a high risk for interfamilial AF. PMID:23350853

  7. Active controls for flutter suppression and gust alleviation in supersonic aircraft. [YF-17 flutter model

    NASA Technical Reports Server (NTRS)

    Nissim, E.

    1980-01-01

    Results of work done on active controls on the modified YF-17 flutter model are summarized. The basic derivation of a suitable control law is discussed. It is shown that discrepencies found between analysis and wind tunnel tests originate from the lack of proper implementation of the desired control law. Program capabilities are described.

  8. An iterative transformation procedure for numerical solution of flutter and similar characteristics-value problems

    NASA Technical Reports Server (NTRS)

    Gossard, Myron L

    1952-01-01

    An iterative transformation procedure suggested by H. Wielandt for numerical solution of flutter and similar characteristic-value problems is presented. Application of this procedure to ordinary natural-vibration problems and to flutter problems is shown by numerical examples. Comparisons of computed results with experimental values and with results obtained by other methods of analysis are made.

  9. Real-time flutter identification

    NASA Technical Reports Server (NTRS)

    Roy, R.; Walker, R.

    1985-01-01

    The techniques and a FORTRAN 77 MOdal Parameter IDentification (MOPID) computer program developed for identification of the frequencies and damping ratios of multiple flutter modes in real time are documented. Physically meaningful model parameterization was combined with state of the art recursive identification techniques and applied to the problem of real time flutter mode monitoring. The performance of the algorithm in terms of convergence speed and parameter estimation error is demonstrated for several simulated data cases, and the results of actual flight data analysis from two different vehicles are presented. It is indicated that the algorithm is capable of real time monitoring of aircraft flutter characteristics with a high degree of reliability.

  10. Semi-empirical model for prediction of unsteady forces on an airfoil with application to flutter

    NASA Technical Reports Server (NTRS)

    Mahajan, Aparajit J.; Kaza, Krishna Rao V.

    1992-01-01

    A semi-empirical model is described for predicting unsteady aerodynamic forces on arbitrary airfoils under mildly stalled and unstalled conditions. Aerodynamic forces are modeled using second order ordinary differential equations for lift and moment with airfoil motion as the input. This model is simultaneously integrated with structural dynamics equations to determine flutter characteristics for a two degrees-of-freedom system. Results for a number of cases are presented to demonstrate the suitability of this model to predict flutter. Comparison is made to the flutter characteristics determined by a Navier-Stokes solver and also the classical incompressible potential flow theory.

  11. Semi-empirical model for prediction of unsteady forces on an airfoil with application to flutter

    NASA Technical Reports Server (NTRS)

    Mahajan, A. J.; Kaza, K. R. V.; Dowell, E. H.

    1993-01-01

    A semi-empirical model is described for predicting unsteady aerodynamic forces on arbitrary airfoils under mildly stalled and unstalled conditions. Aerodynamic forces are modeled using second order ordinary differential equations for lift and moment with airfoil motion as the input. This model is simultaneously integrated with structural dynamics equations to determine flutter characteristics for a two degrees-of-freedom system. Results for a number of cases are presented to demonstrate the suitability of this model to predict flutter. Comparison is made to the flutter characteristics determined by a Navier-Stokes solver and also the classical incompressible potential flow theory.

  12. Flutter and forced response of mistuned rotors using standing wave analysis

    NASA Technical Reports Server (NTRS)

    Dugundji, J.; Bundas, D. J.

    1983-01-01

    A standing wave approach is applied to the analysis of the flutter and forced response of tuned and mistuned rotors. The traditional traveling wave cascade airforces are recast into standing wave arbitrary motion form using Pade approximants, and the resulting equations of motion are written in the matrix form. Applications for vibration modes, flutter, and forced response are discussed. It is noted that the standing wave methods may prove to be more versatile for dealing with certain applications, such as coupling flutter with forced response and dynamic shaft problems, transient impulses on the rotor, low-order engine excitation, bearing motions, and mistuning effects in rotors.

  13. Flutter and forced response of mistuned rotors using standing wave analysis

    NASA Technical Reports Server (NTRS)

    Bundas, D. J.; Dungundji, J.

    1983-01-01

    A standing wave approach is applied to the analysis of the flutter and forced response of tuned and mistuned rotors. The traditional traveling wave cascade airforces are recast into standing wave arbitrary motion form using Pade approximants, and the resulting equations of motion are written in the matrix form. Applications for vibration modes, flutter, and forced response are discussed. It is noted that the standing wave methods may prove to be more versatile for dealing with certain applications, such as coupling flutter with forced response and dynamic shaft problems, transient impulses on the rotor, low-order engine excitation, bearing motion, and mistuning effects in rotors.

  14. Utilizing Flight Data to Update Aeroelastic Stability Estimates

    NASA Technical Reports Server (NTRS)

    Lind, Rick; Brenner, Marty

    1997-01-01

    Stability analysis of high performance aircraft must account for errors in the system model. A method for computing flutter margins that incorporates flight data has been developed using robust stability theory. This paper considers applying this method to update flutter margins during a post-flight or on-line analysis. Areas of modeling uncertainty that arise when using flight data with this method are investigated. The amount of conservatism in the resulting flutter margins depends on the flight data sets used to update the model. Post-flight updates of flutter margins for an F/A-18 are presented along with a simulation of on-line updates during a flight test.

  15. Transonic Flutter Suppression Control Law Design, Analysis and Wind-Tunnel Results

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1999-01-01

    The benchmark active controls technology and wind tunnel test program at NASA Langley Research Center was started with the objective to investigate the nonlinear, unsteady aerodynamics and active flutter suppression of wings in transonic flow. The paper will present the flutter suppression control law design process, numerical nonlinear simulation and wind tunnel test results for the NACA 0012 benchmark active control wing model. The flutter suppression control law design processes using classical, and minimax techniques are described. A unified general formulation and solution for the minimax approach, based on the steady state differential game theory is presented. Design considerations for improving the control law robustness and digital implementation are outlined. It was shown that simple control laws when properly designed based on physical principles, can suppress flutter with limited control power even in the presence of transonic shocks and flow separation. In wind tunnel tests in air and heavy gas medium, the closed-loop flutter dynamic pressure was increased to the tunnel upper limit of 200 psf. The control law robustness and performance predictions were verified in highly nonlinear flow conditions, gain and phase perturbations, and spoiler deployment. A non-design plunge instability condition was also successfully suppressed.

  16. Optimization of cascade blade mistuning under flutter and forced response constraints

    NASA Technical Reports Server (NTRS)

    Murthy, D. V.; Haftka, R. T.

    1984-01-01

    In the development of modern turbomachinery, problems of flutter instabilities and excessive forced response of a cascade of blades that were encountered have often turned out to be extremely difficult to eliminate. The study of these instabilities and the forced response is complicated by the presence of mistuning; that is, small differences among the individual blades. The theory of mistuned cascade behavior shows that mistuning can have a beneficial effect on the stability of the rotor. This beneficial effect is produced by the coupling between the more stable and less stable flutter modes introduced by mistuning. The effect of mistuning on the forced response can be either beneficial or adverse. Kaza and Kielb have studied the effects of two types of mistuning on the flutter and forced response: alternate mistuning where alternte blades are identical and random mistuning. The objective is to investigate other patterns of mistuning which maximize the beneficial effects on the flutter and forced response of the cascade. Numerical optimization techniques are employed to obtain optimal mistuning patterns. The optimization program seeks to minimize the amount of mistuning required to satisfy constraints on flutter speed and forced response.

  17. About the Effect of Control on Flutter and Post-Flutter of a Supersonic/Hypersonic Cross-Sectional Wing

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Librescu, Liviu; Marzocca, Piergiovanni

    2001-01-01

    The control of the flutter instability and the conversion of the dangerous character of the flutter instability boundary into the undangerous one of a cross-sectional wing in a supersonic/hypersonic flow field is presented. The objective of this paper is twofold: i) to analyze the implications of nonlinear unsteady aerodynamics and physical nonlinearities on the character of the instability boundary in the presence of a control capability, and ii) to outline the effects played in the same respect by some important parameters of the aeroelastic system. As a by-product of this analysis, the implications of the active control on the linearized flutter behavior of the system are captured and emphasized. The bifurcation behavior of the open/closed loop aeroelastic system in the vicinity of the flutter boundary is studied via the use of a new methodology based on the Liapunov First Quantity. The expected outcome of this study is: a) to greatly enhance the scope and reliability of the aeroelastic analysis and design criteria of advanced supersonic/hypersonic flight vehicles and, b) provide a theoretical basis for the analysis of more complex nonlinear aeroelastic systems.

  18. About the Effect of Control on Flutter and Post-Flutter of a Supersonic/Hypersonic Cross-Sectional Wing

    NASA Technical Reports Server (NTRS)

    Marzocca, Piergiovanni; Librescu, Liviu; Silva, Walter A.

    2000-01-01

    The control of the flutter instability and the conversion of the dangerous character of the flutter instability boundary into the undangerous one of a cross-sectional wing in a supersonic/hypersonic flow field is presented. The objective of this paper is twofold: i) to analyze the implications of nonlinear unsteady aerodynamics and physical nonlinearities on the character of the instability boundary in the presence of a control capability, and ii) to outline the effects played in the same respect by some important parameters of the aeroelastic system. As a by-product of this analysis, the implications of the active control on the linearized flutter behavior of the system are captured and emphasized. The bifurcation behavior of the open/closed loop aeroelastic system in the vicinity of the flutter boundary is studied via the use of a new methodology based on the Liapunov First Quantity. The expected outcome of this study is: a) to greatly enhance the scope and reliability of the aeroelastic analysis and design criteria of advanced supersonic/hypersonic flight vehicles and, b) provide a theoretical basis for the analysis of more complex nonlinear aeroelastic systems.

  19. Therapeutical considerations in associated atrial fibrillation and heart failure.

    PubMed

    Mitu, O; Mitu, F; Constantin, S; Cojocaru, Elena; Leon, Maria-Magdalena

    2014-01-01

    Atrial fibrillation is a supraventricular tachyarrhythmia very common in medical practice, often associated with heart failure. Pathophysiological relationship between atrial fibrillation and heart failure is in the attention of numerous case studies, being incomplete elucidated. We made a retrospective study on patients with both diseases, hospitalized in Cardiovascular Rehabilitation Hospital, Iasi, during 01.01.2013 - 31.12.2013. The obtained data allowed the classification of patients according to gender distribution, age groups, area of origin, clinical aspects, and association with other diseases, instituted treatment and appreciation of CHADS2 score. Data interpretation was performed with appropriate statistical methods. We found a higher frequency of the disease among male patients, male: female ratio being 2:1; the most of the patients lived in urban area. The pick of diseases incidence was in patients over 65 years with a total percentage of 70.84% of cases. We noted that the most common symptoms were exertional dyspnea (in all patients), palpitations, dizziness, headache, fatigue, asthenia, dyspnea at rest and pain/chest pressure. In our study, the majority of patients received the beta-blocker--digoxin combination (46 patients, 40 patients respectively). The coexistence of the two disorders could be explained by identifying common risk factors. Beta blockers should be the first therapeutic option in patients with chronic heart failure and atrial fibrillation because they have the effect of controlling heart rate and improve survival in patients with these disorders. Meanwhile, digoxin is a drug, only certain conditions of high accuracy monitoring; whose major clinical indications are heart failure and atrial rhythm disturbances.

  20. A log-Weibull spatial scan statistic for time to event data.

    PubMed

    Usman, Iram; Rosychuk, Rhonda J

    2018-06-13

    Spatial scan statistics have been used for the identification of geographic clusters of elevated numbers of cases of a condition such as disease outbreaks. These statistics accompanied by the appropriate distribution can also identify geographic areas with either longer or shorter time to events. Other authors have proposed the spatial scan statistics based on the exponential and Weibull distributions. We propose the log-Weibull as an alternative distribution for the spatial scan statistic for time to events data and compare and contrast the log-Weibull and Weibull distributions through simulation studies. The effect of type I differential censoring and power have been investigated through simulated data. Methods are also illustrated on time to specialist visit data for discharged patients presenting to emergency departments for atrial fibrillation and flutter in Alberta during 2010-2011. We found northern regions of Alberta had longer times to specialist visit than other areas. We proposed the spatial scan statistic for the log-Weibull distribution as a new approach for detecting spatial clusters for time to event data. The simulation studies suggest that the test performs well for log-Weibull data.

  1. Management of Stroke Prevention in Canadian Patients with Atrial Fibrillation at Moderate to High Risk of Stroke

    PubMed Central

    Semchuk, William M; Levac, Brandon; Lara, Muria; Shakespeare, Annabelle; Evers, Thomas; Bolt, Jennifer

    2013-01-01

    Background Many patients with atrial fibrillation who are at moderate to high risk of stroke do not receive anticoagulation with vitamin K antagonists (VKAs) in accordance with recommendations. Objective: To determine (1) why Canadian patients with atrial fibrillation who are potentially eligible for VKA do not receive this therapy, (2) why Canadian primary care physicians discontinue VKA therapy, and (3) why VKA therapy is perceived as difficult to manage. Methods: The study involved a chart review of 3 cohorts of patients with nonvalvular atrial fibrillation at moderate to high risk of stroke: patients who had never received VKA treatment (VKA-naive), those whose treatment had been discontinued, and those whose VKA treatment was considered difficult to manage. Results: Charts for 187 patients (mean age 78.4 years, standard deviation 8.9 years) treated at 39 primary care sites were reviewed (62 treatment-naive, 42 with therapy discontinued, and 83 whose therapy was considered difficult to manage). Atrial fibrillation was paroxysmal in 82 (44%) of the patients, persistent in 47 patients (25%), and permanent in 58 (31%). One patient in each of the 3 cohorts had experienced a stroke during the 6 months before study participation. Bleeding events were more frequent among patients who had discontinued VKA therapy than in the other 2 groups. Among those whose therapy was discontinued and those whose therapy was difficult to manage, the mean time in the therapeutic range was 46.3% and 56.4%, respectively. The most common reason for not initiating VKA therapy in treatment-naive patients was the transient nature of atrial fibrillation (25/62 [40%]). The most common reason for discontinuation of VKA therapy was a bleeding event (10/42 [24%]). The presence of a concomitant chronic disease was the most common reason that a patient’s therapy was considered difficult to manage (46/83 [55%]). Conclusions: VKA therapy was not initiated or was discontinued for various reasons. Multiple comorbid conditions made management of VKA therapy more difficult. These findings reflect the challenges that primary care physicians experience in managing the care of patients with atrial fibrillation. PMID:24159232

  2. Management of stroke prevention in canadian patients with atrial fibrillation at moderate to high risk of stroke.

    PubMed

    Semchuk, William M; Levac, Brandon; Lara, Muria; Shakespeare, Annabelle; Evers, Thomas; Bolt, Jennifer

    2013-09-01

    Many patients with atrial fibrillation who are at moderate to high risk of stroke do not receive anticoagulation with vitamin K antagonists (VKAs) in accordance with recommendations. To determine (1) why Canadian patients with atrial fibrillation who are potentially eligible for VKA do not receive this therapy, (2) why Canadian primary care physicians discontinue VKA therapy, and (3) why VKA therapy is perceived as difficult to manage. The study involved a chart review of 3 cohorts of patients with nonvalvular atrial fibrillation at moderate to high risk of stroke: patients who had never received VKA treatment (VKA-naive), those whose treatment had been discontinued, and those whose VKA treatment was considered difficult to manage. Charts for 187 patients (mean age 78.4 years, standard deviation 8.9 years) treated at 39 primary care sites were reviewed (62 treatment-naive, 42 with therapy discontinued, and 83 whose therapy was considered difficult to manage). Atrial fibrillation was paroxysmal in 82 (44%) of the patients, persistent in 47 patients (25%), and permanent in 58 (31%). One patient in each of the 3 cohorts had experienced a stroke during the 6 months before study participation. Bleeding events were more frequent among patients who had discontinued VKA therapy than in the other 2 groups. Among those whose therapy was discontinued and those whose therapy was difficult to manage, the mean time in the therapeutic range was 46.3% and 56.4%, respectively. The most common reason for not initiating VKA therapy in treatment-naive patients was the transient nature of atrial fibrillation (25/62 [40%]). The most common reason for discontinuation of VKA therapy was a bleeding event (10/42 [24%]). The presence of a concomitant chronic disease was the most common reason that a patient's therapy was considered difficult to manage (46/83 [55%]). VKA therapy was not initiated or was discontinued for various reasons. Multiple comorbid conditions made management of VKA therapy more difficult. These findings reflect the challenges that primary care physicians experience in managing the care of patients with atrial fibrillation.

  3. Left Atrial Enlargement in Young High-Level Endurance Athletes - Another Sign of Athlete's Heart?

    PubMed

    Król, Wojciech; Jędrzejewska, Ilona; Konopka, Marcin; Burkhard-Jagodzińska, Krystyna; Klusiewicz, Andrzej; Pokrywka, Andrzej; Chwalbińska, Jolanta; Sitkowski, Dariusz; Dłużniewski, Mirosław; Mamcarz, Artur; Braksator, Wojciech

    2016-12-01

    Enlargement of the left atrium is perceived as a part of athlete's heart syndrome, despite the lack of evidence. So far, left atrial size has not been assessed in the context of exercise capacity. The hypothesis of the present study was that LA enlargement in athletes was physiological and fitness-related condition. In addition, we tried to assess the feasibility and normal values of left atrial strain parameters and their relationship with other signs of athlete's heart. The study group consisted of 114 international-level rowers (17.5 ± 1.5 years old; 46.5% women). All participants underwent a cardio-pulmonary exercise test and resting transthoracic echocardiography. Beside standard echocardiographic measurements, two dimensional speckle tracking echocardiography was used to assess average peak atrial longitudinal strain, peak atrial contraction strain and early left atrial diastolic longitudinal strain. Mild, moderate and severe left atrial enlargement was present in 27.2°%, 11.4% and 4.4% athletes, respectively. There were no significant differences between subgroups with different range of left atrial enlargement in any of echocardiographic parameters of the left ventricle diastolic function, filling pressure or hypertrophy. A significant correlation was found between the left atrial volume index and maximal aerobic capacity (R > 0.3; p < 0.001). Left atrial strain parameters were independent of atrial size, left ventricle hypertrophy and left ventricle filling pressure. Decreased peak atrial longitudinal strain was observed in 4 individuals (3.5%). We concluded that LA enlargement was common in healthy, young athletes participating in endurance sport disciplines with a high level of static exertion and was strictly correlated with exercise capacity, therefore, could be perceived as another sign of athlete's heart.

  4. The heart is a representation of life: an exploration of illness beliefs in couples living with atrial fibrillation.

    PubMed

    Dalteg, Tomas; Sandberg, Jonas; Malm, Dan; Sandgren, Anna; Benzein, Eva

    2017-11-01

    To explore illness beliefs in couples where one spouse has atrial fibrillation. Beliefs are the lenses through which we view the world, guiding our behaviour and constructing our lives. Couples evolve an ecology of beliefs from their interaction whereby their actions and choices arise from their beliefs. Atrial fibrillation is a common cardiac arrhythmia that has implications for both patients and partners. A couple's illness beliefs play an important role in convalescence and illness management, and no previous studies have explored illness beliefs in couples living with atrial fibrillation. A qualitative hermeneutic design. Data collection constituted in-depth interviews with nine couples (patient and partner together). Hermeneutic philosophy as described by Gadamer was used to interpret and to understand illness beliefs in couples living with atrial fibrillation. The findings revealed both core illness beliefs and secondary illness beliefs. From the core illness belief 'The heart is a representation of life', two secondary illness beliefs were derived: atrial fibrillation is a threat to life and atrial fibrillation can and must be explained. From the core illness belief 'Change is an integral part of life', two secondary illness beliefs were derived: atrial fibrillation is a disruption in our lives and atrial fibrillation will not interfere with our lives. Finally, from the core illness belief 'Adaptation is fundamental in life', two secondary illness beliefs were derived: atrial fibrillation entails adjustment in daily life and atrial fibrillation entails confidence in and adherence to professional care. Couples' interaction has developed mutual illness beliefs regarding atrial fibrillation that guide them in their daily lives and influence their decisions. The adoption of a family-centred perspective in cardiovascular care settings is warranted. © 2017 John Wiley & Sons Ltd.

  5. Early Efficacy Analysis of Biatrial Ablation versus Left and Simplified Right Atrial Ablation for Atrial Fibrillation Treatment in Patients with Rheumatic Heart Disease.

    PubMed

    Liu, Hong; Chen, Lin; Xiao, Yingbin; Ma, Ruiyan; Hao, Jia; Chen, Baicheng; Qin, Chuan; Cheng, Wei

    2015-08-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia. About 60% of patients with rheumatic heart disease have persistent AF. A total of 197 patients underwent valve replacement concomitant bipolar radiofrequency ablation (BRFA). Patients were divided into the biatrial ablation group and the simplified right atrial ablation group. In biatrial ablation group, the patients underwent a complete left and right atrial ablation. In simplified right atrial ablation group, the patients underwent a complete left atrial ablation and a simplified right atrial ablation. The conversion of sinus rhythm (SR) was high in both groups during the follow-up period. In the simplified right atrial ablation group, SR conversion rate was 88.29% at discharge. At six months and 12 months after surgery, 87.39% of patients and 86.49% of patients were in SR free of antiarrhythmic drugs, respectively. While in the biatrial ablation group, SA conversion rate was 89.53% at discharge. Percentage of patients in SR free of antiarrhythmic drugs was 88.37% and 88.37% at six months and 12 months after surgery, respectively. Echocardiography showed left atrial diameter decreased significantly after the surgery in the two groups. The ejection fraction and fractional shortening were improved significantly, without significant differences between the two groups. The results suggest that the concomitant left atrial and simplified right atrial BRFA for AF in patients undergoing valve replacement can achieve similar early efficiency as biatrial ablation. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  6. Vitamin D status is note related to development of atrial fibrillation in the community

    USDA-ARS?s Scientific Manuscript database

    Atrial fibrillation (AF) is common and is an important cause of cardiovascular morbidity and mortality. Vitamin D is an emerging risk factor in cardiovascular disease, and vitamin D status is modifiable. Thus, we sought to investigate whether vitamin D status predisposed to the development of AF in ...

  7. Pressure measurements on a rectangular wing with a NACA0012 airfoil during conventional flutter

    NASA Technical Reports Server (NTRS)

    Rivera, Jose A., Jr.; Dansberry, Bryan E.; Durham, Michael H.; Bennett, Robert M.; Silva, Walter A.

    1992-01-01

    The Structural Dynamics Division at NASA LaRC has started a wind tunnel activity referred to as the Benchmark Models Program. The primary objective of the program is to acquire measured dynamic instability and corresponding pressure data that will be useful for developing and evaluating aeroelastic type CFD codes currently in use or under development. The program is a multi-year activity that will involve testing of several different models to investigate various aeroelastic phenomena. The first model consisted of a rigid semispan wing having a rectangular planform and a NACA 0012 airfoil shape which was mounted on a flexible two degree-of-freedom mount system. Two wind-tunnel tests were conducted with the first model. Several dynamic instability boundaries were investigated such as a conventional flutter boundary, a transonic plunge instability region near Mach = 0.90, and stall flutter. In addition, wing surface unsteady pressure data were acquired along two model chords located at the 60 to 95-percent span stations during these instabilities. At this time, only the pressure data for the conventional flutter boundary is presented. The conventional flutter boundary and the wing surface unsteady pressure measurements obtained at the conventional flutter boundary test conditions in pressure coefficient form are presented. Wing surface steady pressure measurements obtained with the model mount system rigidized are also presented. These steady pressure data were acquired at essentially the same dynamic pressure at which conventional flutter had been encountered with the mount system flexible.

  8. Cardioembolic Stroke.

    PubMed

    O'Carroll, Cumara B; Barrett, Kevin M

    2017-02-01

    Cardioembolic stroke is common and disproportionately more disabling than nonembolic mechanisms of stroke. Its incidence is expected to rise because of the age-related incidence of atrial fibrillation and an aging population. This article summarizes the different causes of cardioembolism and outlines current management guidelines. Since cardioembolic stroke is not a single disease entity, its diagnosis requires initial clinical suspicion and a comprehensive evaluation, including ECG, echocardiography, brain imaging, and cardiac monitoring. Atrial fibrillation is the most common cause of cardioembolic stroke, and anticoagulation is usually recommended. This article reviews risk stratification models to assist in the decision-making process and highlights the increased use of novel oral anticoagulants for stroke prevention in atrial fibrillation. New data support the importance of prolonged cardiac monitoring for diagnosing occult atrial fibrillation. Current data on other mechanisms of cardioembolic stroke, such as prosthetic heart valves and aortic arch atherosclerosis, are also presented, and the available evidence regarding patent foramen ovale closure in cryptogenic stroke is summarized. Cardioembolism is an important cause of ischemic stroke, with diverse underlying mechanisms requiring a tailored approach to diagnosis, management, and prevention.

  9. Psoriasis increases risk of new-onset atrial fibrillation: a systematic review and meta-analysis of prospective observational studies.

    PubMed

    Upala, Sikarin; Shahnawaz, Afeefa; Sanguankeo, Anawin

    2017-08-01

    Psoriasis is a common chronic immune-mediated dermatological disease that increases the risk of cardiovascular disease. We conducted a systematic review and meta-analysis to evaluate the association between psoriasis and atrial fibrillation from prospective observational studies. A comprehensive search of the databases of the MEDLINE and EMBASE was performed from inception through November 2015. The inclusion criterion was the prospective observational study that assessed the risk of new-onset atrial fibrillation in adults with psoriasis. Outcome was the adjusted hazard ratio (HR) of atrial fibrillation comparison between patients with psoriasis and controls. Pooled HR and 95% confidence intervals (CI) were calculated using a random-effects model. The initial search yielded 176 articles. Fifteen articles underwent full-length review and data were extracted from 4 observational studies. Incidence of atrial fibrillation was ascertained by cardiologist-reviewed electrocardiograms. There was a significant increased risk of new-onset atrial fibrillation in patients with psoriasis compared to controls with a pooled HR 1.42 (95%CI 1.22-1.65). Our meta-analysis of prospective studies demonstrated that patients with psoriasis have increased risk of new-onset atrial fibrillation. Future interventional studies addressing the impact of psoriasis treatment and prevention of atrial fibrillation should be performed.

  10. Thyrotoxic atrial fibrillation.

    PubMed

    Parmar, Malvinder S

    2005-01-04

    Atrial fibrillation is the most common cardiac complication of hyperthyroidism and occurs in 15% of patients with hyperthyroidism. It is associated with a higher risk of thromboembolism that often involves the central nervous system. Oral anticoagulation is important in the majority of these patients to prevent thromboembolic complications. These patients require adjustment in the dose of various rate-controlling agents because of increased clearance associated with hyperthyroidism and a decrease in warfarin dosage because of increased clearance of vitamin K-dependent clotting factors. The management of thyrotoxic atrial fibrillation is summarized in this clinical review.

  11. Impact of aldosterone antagonists on the substrate for atrial fibrillation: Aldosterone promotes oxidative stress and atrial structural/electrical remodeling

    PubMed Central

    Mayyas, Fadia; Alzoubi, Karem H.; Van Wagoner, David R.

    2014-01-01

    Atrial fibrillation (AF), the most common cardiac arrhythmia, is an electrocardiographic description of a condition with multiple and complex underlying mechanisms. Oxidative stress is an important driver of structural remodeling that creates a substrate for AF. Oxidant radicals may promote increase of atrial oxidative damage, electrical and structural remodeling, and atrial inflammation. AF and other cardiovascular morbidities activate angiotensin (Ang-II)-dependent and independent cascades. A key component of the renin–angiotensin-aldosterone system (RAAS) is the mineralocorticoid aldosterone. Recent studies provide evidence of myocardial aldosterone synthesis. Aldosterone promotes cardiac oxidative stress, inflammation and structural/electrical remodeling via multiple mechanisms. In HF patients, aldosterone production is enhanced. In patients and in experimental HF and AF models, aldosterone receptor antagonists have favorable influences on cardiac remodeling and oxidative stress. Therapeutic approaches that seek to reduce AF burden by modulating the aldosterone system are likely beneficial but underutilized. PMID:23993726

  12. Atrial electrogram interpretation improves after an innovative education program.

    PubMed

    Preston, Julie L; Currey, Judy; Considine, Julie

    2015-01-01

    To avoid adverse patient outcomes from inappropriate treatment, it is recommended that an atrial electrogram (AEG) be recorded whenever atrial arrhythmias develop in patients after cardiac surgery. However, AEGs are not commonly performed because nurses lack knowledge about differentiating atrial rhythms on AEGs. To investigate whether completing a novel online evidence-based education program on interpreting AEGs would improve critical care nurses' AEG interpretation. Specialized critical care nurses were taught about obtaining and interpreting atrial rhythms on AEGs using a 42-minute online mini-movie. AEG interpretation was assessed pre and two and eight weeks post-intervention. AEG interpretation increased two weeks post intervention and was retained at eight weeks. Some participants used this newly acquired knowledge to interpret arrhythmias that were not taught during the education program. Accurate interpretation of AEGs is an easy skill for specialized critical care nurses to learn via an online education program.

  13. Two degree-of-freedom flutter solution for a personal computer

    NASA Technical Reports Server (NTRS)

    Turnock, D. L.

    1985-01-01

    A computer programmed flutter solution has been written in the BASIC language for a personal computer. The program is for two degree-of-freedom bending torsion flutter applications and utilizes two dimensional Theodorsen aerodynamics. The aerodynamics were modified to include approximations for Mach number (compressibility) effects and aspect ratio (finite span) effects. Input options, user instructions, program listing, and a test case application are included.

  14. The application of measurement techniques to track flutter testing

    NASA Technical Reports Server (NTRS)

    Roglin, H. R.

    1975-01-01

    The application is discussed of measurement techniques to captive flight flutter tests at the Supersonic Naval Ordnance Research Track (SNORT), U. S. Naval Ordnance Test Station, China Lake, California. The high-speed track, by its ability to prove the validity of design and to accurately determine the actual margin of safety, offers a unique method of flutter testing for the aircraft design engineer.

  15. How to perform posterior wall isolation in catheter ablation for atrial fibrillation.

    PubMed

    Sugumar, Hariharan; Thomas, Stuart P; Prabhu, Sandeep; Voskoboinik, Aleksandr; Kistler, Peter M

    2018-02-01

    Catheter ablation has become standard of care in patients with symptomatic atrial fibrillation (AF). Although there have been significant advances in our understanding and technology, a substantial proportion of patients have ongoing AF requiring repeat procedures. Pulmonary vein isolation (PVI) is the cornerstone of AF ablation; however, it is less effective in patients with persistent as opposed to paroxysmal atrial fibrillation. Left atrial posterior wall isolation (PWI) is commonly performed as an adjunct to PVI in patients with persistent AF with nonrandomized studies showing improved outcomes. Anatomical considerations and detailed outline of the various approaches and techniques to performing PWI are detailed, and advantages and pitfalls to assist the clinical electrophysiologist successfully and safely complete PWI are described. © 2017 Wiley Periodicals, Inc.

  16. Detection of Atrial Fibrillation Using Artifical Neural Network with Power Spectrum Density of RR Interval of Electrocardiogram

    NASA Astrophysics Data System (ADS)

    Afdala, Adfal; Nuryani, Nuryani; Satrio Nugroho, Anto

    2017-01-01

    Atrial fibrillation (AF) is a disorder of the heart with fairly high mortality in adults. AF is a common heart arrythmia which is characterized by a missing or irregular contraction of atria. Therefore, finding a method to detect atrial fibrillation is necessary. In this article a system to detect atrial fibrillation has been proposed. Detection system utilized backpropagation artifical neural network. Data input in this method includes power spectrum density of R-peaks interval of electrocardiogram which is selected by wrapping method. This research uses parameter learning rate, momentum, epoch and hidden layer. System produces good performance with accuracy, sensitivity, and specificity of 83.55%, 86.72 % and 81.47 %, respectively.

  17. Role of spiral wave pinning in inhomogeneous active media in the termination of atrial fibrillation by electrical cardioversion.

    PubMed

    Kuklik, Pawel; Wong, Christopher X; Brooks, Anthony G; Zebrowski, Jan Jacek; Sanders, Prashanthan

    2010-03-01

    Atrial fibrillation is the most common type of arrhythmia to affect humans. One of the treatment modalities for atrial fibrillation is an electrical cardioversion. Electrical cardioversion can result in one of three outcomes: an immediate termination of arrhythmic activity, a delayed termination or unsuccessful termination. The mechanism of delayed termination is unknown. Here we present a model of an atrial fibrillation as a coexistence of several spiral waves pinned to the inhomogeneities in active media. We show that in inhomogeneous system delayed termination can be explained as the unpinning of a spiral wave from inhomogeneities and its termination after collision with the edge of the system. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  18. Hyperthyroidism and atrial myxoma--an intriguing cardio-endocrine association.

    PubMed

    Kumar, Gautam; Chow, John T; Klarich, Kyle W; Dean, Diana S

    2007-12-01

    A 65-year-old woman presented with dyspnea and bilateral leg edema for 1 week, worsening fatigue for 1 month, and a 7-lb weight loss over the last summer. She was clinically and biochemically hyperthyroid. Echocardiography revealed a left atrial myxoma measuring 6.2 x 3.3 cm protruding into the mitral orifice and left ventricle during diastole. She was treated for Graves' disease with Iodine-131. Six weeks later, her left atrial myxoma measuring 10.1 x 6.2 x 2.4 cm was resected. She became euthyroid before surgery and then biochemically hypothyroid 6 weeks after radioiodine treatment, for which she subsequently required thyroxine replacement. Atrial myxomas are the most common primary cardiac neoplasms. At least 5% to 10% can be attributed to Carney's complex. More than two-thirds of patients with Carney's complex develop one or more cardiac myxomas. Although atrial myxomas in Carney's complex are histologically indistinguishable from the sporadic form, their clinical presentation and course is distinct. This is the first case of newly diagnosed Graves' disease that has been reported in association with an atrial myxoma. The features discussed in this article help differentiate between syndromic and sporadic atrial myxomas.

  19. Association of Atrial Fibrillation with Morphological and Electrophysiological Changes of the Atrial Myocardium.

    PubMed

    Matějková, Adéla; Šteiner, Ivo

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. For long time it was considered as pure functional disorder, but in recent years, there were identified atrial locations, which are involved in the initiation and maintenance of this arrhythmia. These structural changes, so called remodelation, start at electric level and later they affect contractility and morphology. In this study we attempted to find a possible relation between morphological (scarring, amyloidosis, left atrial (LA) enlargement) and electrophysiological (ECG features) changes in patients with AF. We examined grossly and histologically 100 hearts of necropsy patients - 54 with a history of AF and 46 without AF. Premortem ECGs were evaluated. The patients with AF had significantly heavier heart, larger LA, more severely scarred myocardium of the LA and atrial septum, and more severe amyloidosis in both atria. Severity of amyloidosis was higher in LAs vs. right atria (RAs). Distribution of both fibrosis and amyloidosis was irregular. The most affected area was in the LA anterior wall. Patients with a history of AF and with most severe amyloidosis have more often abnormally long P waves. Finding of long P wave may contribute to diagnosis of a hitherto undisclosed atrial fibrillation.

  20. Mathematical Approaches to Understanding and Imaging Atrial Fibrillation: Significance for Mechanisms and Management

    PubMed Central

    Trayanova, Natalia A

    2014-01-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The mechanisms that govern AF initiation and persistence are highly complex, of dynamic nature, and involve interactions across multiple temporal and spatial scales in the atria. This articles aims to review the mathematical modeling and computer simulation approaches to understanding AF mechanisms and aiding in its management. Various atrial modeling approaches are presented, with descriptions of the methodological basis and advancements in both lower-dimensional and realistic geometry models. A review of the most significant mechanistic insights made by atrial simulations is provided. The article showcases the contributions that atrial modeling and simulation have made not only to our understanding of the pathophysiology of atrial arrhythmias, but also to the development of AF management approaches. A summary of the future developments envisioned for the field of atrial simulation and modeling is also presented. The review contends that computational models of the atria assembled with data from clinical imaging modalities that incorporate electrophysiological and structural remodeling could become a first line of screening for new AF therapies and approaches, new diagnostic developments, and new methods for arrhythmia prevention. PMID:24763468

  1. Is discharge to home after emergency department cardioversion safe for the treatment of recent-onset atrial fibrillation?

    PubMed

    von Besser, Kiera; Mills, Angela M

    2011-12-01

    Recent-onset atrial fibrillation, defined as a first detected or recurrent episode of atrial fibrillation lasting less than 48 hours, is a commonly encountered dysrhythmia in the emergency department (ED). Cardioversion of stable patients in the ED with recent-onset atrial fibrillation without antecedent anticoagulation would allow for these patients to be discharged directly to home. We searched the literature to determine whether any studies have investigated the safety of this management strategy and identified five that addressed this question. These studies are reviewed herein; importantly, not one ED patient who was cardioverted in any of the five studies suffered a thromboembolic event - the feared complication responsible for most of the controversy surrounding the ED management of atrial fibrillation. According to the available evidence, we conclude that it would be within the standard of care to discharge home stable patients with recent-onset atrial fibrillation after cardioversion in the ED with adequate follow-up. It should be noted that although this strategy is safe and effective, the return visit rate for relapsed atrial fibrillation is 3% to 17%, and patients should be made aware of this possibility.

  2. 4D flow MRI assessment of right atrial flow patterns in the normal heart – influence of caval vein arrangement and implications for the patent foramen ovale

    PubMed Central

    Parikh, Jehill D.; Kakarla, Jayant; Keavney, Bernard; O’Sullivan, John J.; Ford, Gary A.; Blamire, Andrew M.; Hollingsworth, Kieren G.

    2017-01-01

    Aim To investigate atrial flow patterns in the normal adult heart, to explore whether caval vein arrangement and patency of the foramen ovale (PFO) may be associated with flow pattern. Materials and Methods Time-resolved, three-dimensional velocity encoded magnetic resonance imaging (4D flow) was employed to assess atrial flow patterns in thirteen healthy subjects (6 male, 40 years, range 25–50) and thirteen subjects (6 male, 40 years, range 21–50) with cryptogenic stroke and patent foramen ovale (CS-PFO). Right atrial flow was defined as vortical, helico-vortical, helical and multiple vortices. Time-averaged and peak systolic and diastolic flows in the caval and pulmonary veins and their anatomical arrangement were compared. Results A spectrum of right atrial flow was observed across the four defined categories. The right atrial flow patterns were strongly associated with the relative position of the caval veins. Right atrial flow patterns other than vortical were more common (p = 0.015) and the separation between the superior and inferior vena cava greater (10±5mm versus 3±3mm, p = 0.002) in the CS-PFO group. In the left atrium all subjects except one had counter-clockwise vortical flow. Vortex size varied and was associated with left lower pulmonary vein flow (systolic r = 0.61, p = 0.001, diastolic r = 0.63 p = 0.002). A diastolic vortex was less common and time-averaged left atrial velocity was greater in the CS-PFO group (17±2cm/sec versus 15±1, p = 0.048). One CS-PFO subject demonstrated vortical retrograde flow in the descending aortic arch; all other subjects had laminar descending aortic flow. Conclusion Right atrial flow patterns in the normal heart are heterogeneous and are associated with the relative position of the caval veins. Patterns, other than ‘typical’ vortical flow, are more prevalent in the right atrium of those with cryptogenic stroke in the context of PFO. Left atrial flow patterns are more homogenous in normal hearts and show a relationship with flow arising from the left pulmonary veins. PMID:28282389

  3. Flutter and oscillating air-force calculations for an airfoil in two-dimensional supersonic flow

    NASA Technical Reports Server (NTRS)

    Garrick, I E; Rubinow, S I

    1946-01-01

    A connected account is given of the Possio theory of non-stationary flow for small disturbances in a two-dimensional supersonic flow and of its application to the determination of the aerodynamic forces on an oscillating airfoil. Further application is made to the problem of wing flutter in the degrees of freedom - torsion, bending, and aileron rotations. Numerical tables for flutter calculations are provided for various values of the Mach number greater than unity. Results for bending-torsion wing flutter are shown in figures and are discussed. The static instabilities of divergence and aileron reversal are examined as is a one-degree-of-freedom case of torsional oscillatory instability.

  4. Subsonic flutter analysis addition to NASTRAN. [for use with CDC 6000 series digital computers

    NASA Technical Reports Server (NTRS)

    Doggett, R. V., Jr.; Harder, R. L.

    1973-01-01

    A subsonic flutter analysis capability has been developed for NASTRAN, and a developmental version of the program has been installed on the CDC 6000 series digital computers at the Langley Research Center. The flutter analysis is of the modal type, uses doublet lattice unsteady aerodynamic forces, and solves the flutter equations by using the k-method. Surface and one-dimensional spline functions are used to transform from the aerodynamic degrees of freedom to the structural degrees of freedom. Some preliminary applications of the method to a beamlike wing, a platelike wing, and a platelike wing with a folded tip are compared with existing experimental and analytical results.

  5. Surface Acoustic Wave Vibration Sensors for Measuring Aircraft Flutter

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.; Juarez, Peter D.

    2016-01-01

    Under NASA's Advanced Air Vehicles Program the Advanced Air Transport Technology (AATT) Project is investigating flutter effects on aeroelastic wings. To support that work a new method for measuring vibrations due to flutter has been developed. The method employs low power Surface Acoustic Wave (SAW) sensors. To demonstrate the ability of the SAW sensor to detect flutter vibrations the sensors were attached to a Carbon fiber-reinforced polymer (CFRP) composite panel which was vibrated at six frequencies from 1Hz to 50Hz. The SAW data was compared to accelerometer data and was found to resemble sine waves and match each other closely. The SAW module design and results from the tests are presented here.

  6. Generalization of the subsonic kernel function in the s-plane, with applications to flutter analysis

    NASA Technical Reports Server (NTRS)

    Cunningham, H. J.; Desmarais, R. N.

    1984-01-01

    A generalized subsonic unsteady aerodynamic kernel function, valid for both growing and decaying oscillatory motions, is developed and applied in a modified flutter analysis computer program to solve the boundaries of constant damping ratio as well as the flutter boundary. Rates of change of damping ratios with respect to dynamic pressure near flutter are substantially lower from the generalized-kernel-function calculations than from the conventional velocity-damping (V-g) calculation. A rational function approximation for aerodynamic forces used in control theory for s-plane analysis gave rather good agreement with kernel-function results, except for strongly damped motion at combinations of high (subsonic) Mach number and reduced frequency.

  7. Generalized Reduced Order Modeling of Aeroservoelastic Systems

    NASA Astrophysics Data System (ADS)

    Gariffo, James Michael

    Transonic aeroelastic and aeroservoelastic (ASE) modeling presents a significant technical and computational challenge. Flow fields with a mixture of subsonic and supersonic flow, as well as moving shock waves, can only be captured through high-fidelity CFD analysis. With modern computing power, it is realtively straightforward to determine the flutter boundary for a single structural configuration at a single flight condition, but problems of larger scope remain quite costly. Some such problems include characterizing a vehicle's flutter boundary over its full flight envelope, optimizing its structural weight subject to aeroelastic constraints, and designing control laws for flutter suppression. For all of these applications, reduced-order models (ROMs) offer substantial computational savings. ROM techniques in general have existed for decades, and the methodology presented in this dissertation builds on successful previous techniques to create a powerful new scheme for modeling aeroelastic systems, and predicting and interpolating their transonic flutter boundaries. In this method, linear ASE state-space models are constructed from modal structural and actuator models coupled to state-space models of the linearized aerodynamic forces through feedback loops. Flutter predictions can be made from these models through simple eigenvalue analysis of their state-transition matrices for an appropriate set of dynamic pressures. Moreover, this analysis returns the frequency and damping trend of every aeroelastic branch. In contrast, determining the critical dynamic pressure by direct time-marching CFD requires a separate run for every dynamic pressure being analyzed simply to obtain the trend for the critical branch. The present ROM methodology also includes a new model interpolation technique that greatly enhances the benefits of these ROMs. This enables predictions of the dynamic behavior of the system for flight conditions where CFD analysis has not been explicitly performed, thus making it possible to characterize the overall flutter boundary with far fewer CFD runs. A major challenge of this research is that transonic flutter boundaries can involve multiple unstable modes of different types. Multiple ROM-based studies on the ONERA M6 wing are shown indicating that in addition to classic bending-torsion (BT) flutter modes. which become unstable above a threshold dynamic pressure after two natural modes become aerodynamically coupled, some natural modes are able to extract energy from the air and become unstable by themselves. These single-mode instabilities tend to be weaker than the BT instabilities, but have near-zero flutter boundaries (exactly zero in the absence of structural damping). Examples of hump modes, which behave like natural mode instabilities before stabilizing, are also shown, as are cases where multiple instabilities coexist at a single flight condition. The result of all these instabilities is a highly sensitive flutter boundary, where small changes in Mach number, structural stiffness, and structural damping can substantially alter not only the stability of individual aeroelastic branches, but also which branch is critical. Several studies are shown presenting how the flutter boundary varies with respect to all three of these parameters, as well as the number of structural modes used to construct the ROMs. Finally, an investigation of the effectiveness and limitations of the interpolation scheme is presented. It is found that in regions where the flutter boundary is relatively smooth, the interpolation method produces ROMs that predict the flutter characteristics of the corresponding directly computed models to a high degree of accuracy, even for relatively coarsely spaced data. On the other hand, in the transonic dip region, the interpolated ROMs show significant errors at points where the boundary changes rapidly; however, they still give a good qualitative estimate of where the largest jumps occur.

  8. In-flight automated external defibrillator use and consultation patterns.

    PubMed

    Brown, Aaron Michael; Rittenberger, Jon C; Ammon, Charles M; Harrington, Scott; Guyette, Francis X

    2010-01-01

    Limited information exists about the in-flight use and outcomes associated with automated external defibrillators (AEDs) on commercial airlines. To describe the characteristics and outcomes of AED use during in-flight emergencies including in-flight cardiac arrest and the associated ground medical consultation patterns. We collected cases of AED use that were self-reported to an airline consultation service from three U.S. airlines between May 2004 and March 2009. We reviewed all available data files, related consultation forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as sinus, heart block, supraventricular tachycardia (SVT), atrial fibrillation/flutter, asystole, pulseless electrical activity (PEA), and ventricular fibrillation (VF)/ventricular tachycardia (VT). There were a total of 169 AED applications with 40 cardiac arrests. The mean patient ages were 58 years (standard deviation [SD] 15) and 63 years (SD 12), respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with the following initial rhythms: sinus, 114 (88%); atrial fibrillation/flutter, seven (5%); complete heart block, four (3%); and SVT, four (3%). Presenting rhythms among the cardiac arrest population were as follows: asystole, 16 (40%); VF/VT, 10 (25%); and PEA, 14 (35%). Fourteen patients were defibrillated, including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT, and no medical consultation was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were six (15%; 95% confidence interval [CI] 3-27%) survivors, with five survivals occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after cardiopulmonary resuscitation (CPR) for a junctional rhythm. Survival in those with VF/VT was five of 10 (50%; 95% CI 14-86%). Medications were delivered in two cases. The median time to first shock was 19 seconds (interquartile range [IQR] 12-24 seconds) after AED application. Medical consultation was obtained in 42 (33%) of the 129 AED monitoring cases and 14 (35%) of the 40 cardiac arrest cases. Use of AEDs resulted in 50% survival among those with VF/VT in flight and 15% overall survival for cardiac arrest. Survival is poor among patients presenting with nonshockable rhythms. AEDs are used extensively for in-flight monitoring, with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests.

  9. Sustained Accelerated Idioventricular Rhythm in a Centrifuge-Simulated Suborbital Spaceflight.

    PubMed

    Suresh, Rahul; Blue, Rebecca S; Mathers, Charles; Castleberry, Tarah L; Vanderploeg, James M

    2017-08-01

    Hypergravitational exposures during human centrifugation are known to provoke dysrhythmias, including sinus dysrhythmias/tachycardias, premature atrial/ventricular contractions, and even atrial fibrillations or flutter patterns. However, events are generally short-lived and resolve rapidly after cessation of acceleration. This case report describes a prolonged ectopic ventricular rhythm in response to high G exposure. A previously healthy 30-yr-old man voluntarily participated in centrifuge trials as a part of a larger study, experiencing a total of 7 centrifuge runs over 48 h. Day 1 consisted of two +Gz runs (peak +3.5 Gz, run 2) and two +Gx runs (peak +6.0 Gx, run 4). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +Gx and +Gz). Hemodynamic data collected included blood pressure, heart rate, and continuous three-lead electrocardiogram. Following the final acceleration exposure of the last Day 2 run (peak +4.5 Gx and +4.0 Gz combined, resultant +6.0 G), during a period of idle resting centrifuge activity (resultant vector +1.4 G), the subject demonstrated a marked change in his three-lead electrocardiogram from normal sinus rhythm to a wide-complex ectopic ventricular rhythm at a rate of 91-95 bpm, consistent with an accelerated idioventricular rhythm (AIVR). This rhythm was sustained for 2 m, 24 s before reversion to normal sinus. The subject reported no adverse symptoms during this time. While prolonged, the dysrhythmia was asymptomatic and self-limited. AIVR is likely a physiological response to acceleration and can be managed conservatively. Vigilance is needed to ensure that AIVR is correctly distinguished from other, malignant rhythms to avoid inappropriate treatment and negative operational impacts.Suresh R, Blue RS, Mathers C, Castleberry TL, Vanderploeg JM. Sustained accelerated idioventricular rhythm in a centrifuge-simulated suborbital spaceflight. Aerosp Med Hum Perform. 2017; 88(8):789-793.

  10. Risk Factors For Bradycardia Requiring Pacemaker Implantation In Patients With Atrial Fibrillation

    PubMed Central

    Barrett, Tyler W.; Abraham, Robert L.; Jenkins, Cathy A.; Russ, Stephan; Storrow, Alan B.; Darbar, Dawood

    2012-01-01

    Symptomatic bradycardia may complicate atrial fibrillation (AF) and necessitate a permanent pacemaker. Identifying patients at increased risk for symptomatic bradycardia may reduce associated morbidities and healthcare costs. We investigated predictors for developing bradycardia requiring a permanent pacemaker among AF patients. We reviewed records of all patients treated for AF/flutter in an academic hospital’s emergency department from 8/1/2005 to 8/30/2008. We determined survival and presence of a pacemaker as of 11/1/2011. Cases were defined as patients with pacemakers placed for bradycardia after their AF diagnoses. Patients without a pacemaker who were followed at our hospital comprised the controls. We identified a priori variables for the logistic regression analysis. We fit a post-hoc model adjusting for AF type and atrioventricular nodal blocker (AVN) use. Of the 362 patients in our cohort, 119 cases had permanent pacemakers implanted for bradycardia subsequent to AF diagnosis and 243 controls were alive without a pacemaker. Median and interquartile range follow-up time was 4.5 (3.8 – 5.4) years. Odds ratios and 95% confidence intervals were determined for age at time of AF diagnosis (1.02 [1, 1.04]), female (1.58 [0.95, 2.63]), prior heart failure (2.72 [1.47, 5.01]), and African-American (0.33 [0.12, 0.94]). Post-hoc model identified permanent AF (2.99 [1.61, 5.57]) and AVN use (1.43 [0.85, 2.4]). In conclusion, among AF patients, heart failure and permanent AF each nearly triple the odds of developing bradycardia requiring a permanent pacemaker; while not statistically significant, our results suggest that women are more likely and African-Americans less likely to develop bradycardia requiring pacemaker implantation. PMID:22840846

  11. [Intravenous ablation of the atrio-ventricular junction in patients with supraventricular tachyarrhythmias].

    PubMed

    Drzewiecki, J; Trusz-Gluza, M; Wnuk-Wojnar, A; Jaklik, A; Czerwiński, C; Filipecki, A; Szydło, K; Ciemniewski, Z; Giec, L

    1993-01-01

    Since the first successful therapeutic DC ablation of the AV junction in 1986, we have treated 20 symptomatic patients with drug-refractory supraventricular tachyarrhythmias (average of 6 antiarrhythmic drugs prior to the ablation attempt). The primary rhythm disturbances necessitating ablation were: AV nodal reentrant tachycardia (50% of pts), atrial flutter or fibrillation, with an uncontrolled rapid ventricular response (40%), atrioventricular reentrant tachycardia using an accessory pathway (20%), atrial tachycardia (10%), and junctional reciprocating tachycardia (5%). Percutaneous catheter ablation of the AV junction was made by Gallagher's method. The USCI 4-polar catheter (7F) was used in 40% of pts, and bipolar Cordis catheter (5F) in the remaining 60%. 70% of pts received either one or two shocks, usually of 200 or 300 J during one session. Another 25% received stored cumulative energy from 800 to 1200 J (in two sessions), and one patient--1800 J (during three sessions). In 85% of pts, the immediate post-ablation conduction was third-degree AV block with the escape pacemaker, ranging from 20 to 50 beats/min., which was infra-His in 57%, and supra-His in 43% of pts. In 15% of pts were either first-degree AV block (10%) or normal AV conduction (5%). A His bundle deflection more than 0.2 mV was predictive of successful production of third-degree AV block. Except a mild and transient increase of indicating enzymes (CPK and CPK-MB) we did not observe any other serious complications directly related to the ablalation procedure. Follow-up study included 19 pts (time range from 2 to 56 months, mean 28).(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Finding atrial fibrillation in stroke patients: Randomized evaluation of enhanced and prolonged Holter monitoring--Find-AF(RANDOMISED) --rationale and design.

    PubMed

    Weber-Krüger, Mark; Gelbrich, Götz; Stahrenberg, Raoul; Liman, Jan; Kermer, Pawel; Hamann, Gerhard F; Seegers, Joachim; Gröschel, Klaus; Wachter, Rolf

    2014-10-01

    Detecting paroxysmal atrial fibrillation (AF) in patients with ischemic strokes presenting in sinus rhythm is challenging because episodes are often short, occur randomly, and are frequently asymptomatic. If AF is detected, recurrent thromboembolism can be prevented efficiently by oral anticoagulation. Numerous uncontrolled studies using various electrocardiogram (ECG) devices have established that prolonged ECG monitoring increases the yield of AF detection, but most established procedures are time-consuming and costly. The few randomized trials are mostly limited to cryptogenic strokes. The optimal method, duration, and patient selection remain unclear. Repeated prolonged continuous Holter ECG monitoring to detect paroxysmal AF within an unspecific stroke population may prove to be a widely applicable, effective secondary prevention strategy. Find-AFRANDOMISED is a randomized and controlled prospective multicenter trial. Four hundred patients 60 years or older with manifest (symptoms ≥24 hours or acute computed tomography/magnetic resonance imaging lesion) and acute (symptoms ≤7 days) ischemic strokes will be included at 4 certified stroke centers in Germany. Those with previously diagnosed AF/flutter, indications/contraindications for oral anticoagulation, or obvious causative blood vessel pathologies will be excluded. Patients will be randomized 1:1 to either enhanced and prolonged Holter ECG monitoring (10 days at baseline and after 3 and 6 months) or standard of care (≥24-hour continuous ECG monitoring, according to current stroke guidelines). All patients will be followed up for at least 12 months. The primary end point is newly detected AF (≥30 seconds) after 6 months, confirmed by an independent adjudication committee. We plan to complete recruitment in autumn 2014. First results can be expected by spring 2016. Copyright © 2014 Mosby, Inc. All rights reserved.

  13. Atrial Fibrillation and Colonic Neoplasia in African Americans.

    PubMed

    Nouraie, Mehdi; Kansal, Vandana; Belfonte, Cassius; Ghazvini, Mohammad; Haidari, Tahmineh; Shahnazi, Anahita; Brim, Hassan; Soliman, Elsayed Z; Ashktorab, Hassan

    2015-01-01

    Colorectal cancer (CRC) and atrial fibrillation/flutter (AF) share several risk factors including increasing age and obesity. However, the association between CRC and AF has not been thoroughly examined, especially in African Americans. In this study we aimed to assess the prevalence of AF and its risk factors in colorectal neoplasia in an African American. We reviewed records of 527 African American patients diagnosed with CRC and 1008 patients diagnosed with benign colonic lesions at Howard University Hospital from January 2000 to December 2012. A control group of 731 hospitalized patients without any cancer or colonic lesion were randomly selected from the same time and age range, excluding patients who had diagnosis of both CRC and/or adenoma. The presence or absence of AF was based upon ICD-9 code documentation. The prevalence of AF in these three groups was compared by multivariate logistic regression. The prevalence of AF was highest among CRC patients (10%) followed by adenoma patients (7.2%) then the control group (5.4%, P for trend = 0.002). In the three groups of participants, older age (P<0.008) and heart failure (P<0.001) were significantly associated with higher risk of AF. After adjusting for these risk factors, CRC (OR: 1.4(95%CI):0.9-2.2, P = 0.2) and adenoma (OR: 1.1(95%CI):0.7-1.6, P = 0.7) were not significantly associated AF compared to control group. AF is highly prevalent among CRC patients; 1 in 10 patients had AF in our study. The predictors of AF in CRC was similar to that in adenoma and other patients after adjustment for potential confounders suggesting that the increased AF risk in CRC is explained by higher prevalence of AF risk factors.

  14. Recovery of atrial function after atrial compartment operation for chronic atrial fibrillation in mitral valve disease.

    PubMed

    Shyu, K G; Cheng, J J; Chen, J J; Lin, J L; Lin, F Y; Tseng, Y Z; Kuan, P; Lien, W P

    1994-08-01

    We prospectively studied the recovery of atrial function after atrial compartment operation and mitral valve surgery in patients with chronic atrial fibrillation caused by mitral valve disease. Chronic atrial fibrillation is the most common arrhythmia in mitral valve disease. This arrhythmia is associated with excessive morbidity and mortality. Mitral valve surgery alone rarely eliminates it. Twenty-two patients underwent mitral valve surgery and a new surgical method, atrial compartment operation. Doppler echocardiography was performed in all patients before operation and at 1 week and 2 and 6 months after operation in the successful cardioversion group. Peak early diastolic (E) and atrial (A) filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves were measured. Sinus rhythm was restored immediately after operation in 91% of patients and was maintained for > 1 week in 15 (68%) of 22 patients and > 6 months in 14 (64%) of 22. Eleven of 15 patients had left atrial paralysis (A/E integral ratio 0) at 1 week and 6 of 14 patients at 2 months. Nine of 15 patients had right atrial paralysis (A/E integral ratio 0) at 1 week and 1 of 14 patients at 2 months. Both left and right atrial contractile function (presence of an A wave on Doppler findings) was detected at 6 months in 14 patients. Mean (+/- SD) peak atrial filling velocity of the mitral valve was 15 +/- 26 cm/s at 1 week, 38 +/- 39 cm/s at 2 months and 93 +/- 32 cm/s at 6 months (p < 0.001). Mean peak atrial filling velocity of the tricuspid valve was 14 +/- 19 cm/s at 1 week, 33 +/- 19 cm/s at 2 months and 50 +/- 19 cm/s at 6 months (p < 0.001). Peak early diastolic and atrial filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves increased significantly from 1 week to 6 months. Chronic atrial fibrillation in mitral valve disease can often be eliminated by atrial compartment operation. No surgical mortality or significant complications were encountered. Both left and right atrial function, as manifested by Doppler findings, recover after compartment operation and improve over time. The mechanical function of the right atrium recovers earlier than that of the left.

  15. Transonic flight flutter tests of a control surface utilizing an impedance response technique

    NASA Technical Reports Server (NTRS)

    Mirowitz, L. I.

    1975-01-01

    Transonic flight flutter tests of the XF3H-1 Demon Airplane were conducted utilizing a frequency response technique in which the oscillating rudder provides the means of system excitation. These tests were conducted as a result of a rudder flutter incident in the transonic speed range. The technique employed is presented including a brief theoretical development of basic concepts. Test data obtained during the flight are included and the method of interpretation of these data is indicated. This method is based on an impedance matching technique. It is shown that an artificial stabilizing device, such as a damper, may be incorporated in the system for test purposes without complicating the interpretation of the test results of the normal configuration. Data are presented which define the margin of stability introduced to the originally unstable rudder by design changes which involve higher control system stiffness and external damper. It is concluded that this technique of flight flutter testing is a feasible means of obtaining flutter stability information in flight.

  16. Flutter Analysis of the Thermal Protection Layer on the NASA HIAD

    NASA Technical Reports Server (NTRS)

    Goldman, Benjamin D.; Dowell, Earl H.; Scott, Robert C.

    2013-01-01

    A combination of classical plate theory and a supersonic aerodynamic model is used to study the aeroelastic flutter behavior of a proposed thermal protection system (TPS) for the NASA HIAD. The analysis pertains to the rectangular configurations currently being tested in a NASA wind-tunnel facility, and may explain why oscillations of the articles could be observed. An analysis using a linear flat plate model indicated that flutter was possible well within the supersonic flow regime of the wind tunnel tests. A more complex nonlinear analysis of the TPS, taking into account any material curvature present due to the restraint system or substructure, indicated that significantly greater aerodynamic forcing is required for the onset of flutter. Chaotic and periodic limit cycle oscillations (LCOs) of the TPS are possible depending on how the curvature is imposed. When the pressure from the base substructure on the bottom of the TPS is used as the source of curvature, the flutter boundary increases rapidly and chaotic behavior is eliminated.

  17. On-Line Mu Method for Robust Flutter Prediction in Expanding a Safe Flight Envelope for an Aircraft Model Under Flight Test

    NASA Technical Reports Server (NTRS)

    Lind, Richard C. (Inventor); Brenner, Martin J.

    2001-01-01

    A structured singular value (mu) analysis method of computing flutter margins has robust stability of a linear aeroelastic model with uncertainty operators (Delta). Flight data is used to update the uncertainty operators to accurately account for errors in the computed model and the observed range of aircraft dynamics of the aircraft under test caused by time-varying aircraft parameters, nonlinearities, and flight anomalies, such as test nonrepeatability. This mu-based approach computes predict flutter margins that are worst case with respect to the modeling uncertainty for use in determining when the aircraft is approaching a flutter condition and defining an expanded safe flight envelope for the aircraft that is accepted with more confidence than traditional methods that do not update the analysis algorithm with flight data by introducing mu as a flutter margin parameter that presents several advantages over tracking damping trends as a measure of a tendency to instability from available flight data.

  18. Aeroservoelastic Wind-Tunnel Test of the SUGAR Truss Braced Wing Wind-Tunnel Model

    NASA Technical Reports Server (NTRS)

    Scott, Robert C.; Allen, Timothy J.; Funk, Christie J.; Castelluccio, Mark A.; Sexton, Bradley W.; Claggett, Scott; Dykman, John; Coulson, David A.; Bartels, Robert E.

    2015-01-01

    The Subsonic Ultra Green Aircraft Research (SUGAR) Truss-Braced Wing (TBW) aeroservoelastic (ASE) wind-tunnel test was conducted in the NASA Langley Transonic Dynamics Tunnel (TDT) and was completed in April, 2014. The primary goals of the test were to identify the open-loop flutter boundary and then demonstrate flutter suppression. A secondary goal was to demonstrate gust load alleviation (GLA). Open-loop flutter and limit cycle oscillation onset boundaries were identified for a range of Mach numbers and various angles of attack. Two sets of control laws were designed for the model and both sets of control laws were successful in suppressing flutter. Control laws optimized for GLA were not designed; however, the flutter suppression control laws were assessed using the TDT Airstream Oscillation System. This paper describes the experimental apparatus, procedures, and results of the TBW wind-tunnel test. Acquired system ID data used to generate ASE models is also discussed.2 study.

  19. Flutter suppression and stability analysis for a variable-span wing via morphing technology

    NASA Astrophysics Data System (ADS)

    Li, Wencheng; Jin, Dongping

    2018-01-01

    A morphing wing can enhance aerodynamic characteristics and control authority as an alternative to using ailerons. To use morphing technology for flutter suppression, the dynamical behavior and stability of a variable-span wing subjected to the supersonic aerodynamic loads are investigated numerically in this paper. An axially moving cantilever plate is employed to model the variable-span wing, in which the governing equations of motion are established via the Kane method and piston theory. A morphing strategy based on axially moving rates is proposed to suppress the flutter that occurs beyond the critical span length, and the flutter stability is verified by Floquet theory. Furthermore, the transient stability during the morphing motion is analyzed and the upper bound of the morphing rate is obtained. The simulation results indicate that the proposed morphing law, which is varying periodically with a proper amplitude, could accomplish the flutter suppression. Further, the upper bound of the morphing speed decreases rapidly once the span length is close to its critical span length.

  20. A Conceptual Wing Flutter Analysis Tool for Systems Analysis and Parametric Design Study

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    2003-01-01

    An interactive computer program was developed for wing flutter analysis in the conceptual design stage. The objective was to estimate flutt er instability boundaries of a typical wing, when detailed structural and aerodynamic data are not available. Effects of change in key flu tter parameters can also be estimated in order to guide the conceptual design. This userfriendly software was developed using MathCad and M atlab codes. The analysis method was based on non-dimensional paramet ric plots of two primary flutter parameters, namely Regier number and Flutter number, with normalization factors based on wing torsion stiffness, sweep, mass ratio, taper ratio, aspect ratio, center of gravit y location and pitch-inertia radius of gyration. These parametric plo ts were compiled in a Chance-Vought Corporation report from database of past experiments and wind tunnel test results. An example was prese nted for conceptual flutter analysis of outer-wing of a Blended-Wing- Body aircraft.

  1. Eulerian-Lagrangian Simulations of Transonic Flutter Instabilities

    NASA Technical Reports Server (NTRS)

    Bendiksen, Oddvar O.

    1994-01-01

    This paper presents an overview of recent applications of Eulerian-Lagrangian computational schemes in simulating transonic flutter instabilities. This approach, the fluid-structure system is treated as a single continuum dynamics problem, by switching from an Eulerian to a Lagrangian formulation at the fluid-structure boundary. This computational approach effectively eliminates the phase integration errors associated with previous methods, where the fluid and structure are integrated sequentially using different schemes. The formulation is based on Hamilton's Principle in mixed coordinates, and both finite volume and finite element discretization schemes are considered. Results from numerical simulations of transonic flutter instabilities are presented for isolated wings, thin panels, and turbomachinery blades. The results suggest that the method is capable of reproducing the energy exchange between the fluid and the structure with significantly less error than existing methods. Localized flutter modes and panel flutter modes involving traveling waves can also be simulated effectively with no a priori knowledge of the type of instability involved.

  2. Stability analysis of nonlinear autonomous systems - General theory and application to flutter

    NASA Technical Reports Server (NTRS)

    Smith, L. L.; Morino, L.

    1975-01-01

    The analysis makes use of a singular perturbation method, the multiple time scaling. Concepts of stable and unstable limit cycles are introduced. The solution is obtained in the form of an asymptotic expansion. Numerical results are presented for the nonlinear flutter of panels and airfoils in supersonic flow. The approach used is an extension of a method for analyzing nonlinear panel flutter reported by Morino (1969).

  3. Aeroelastic stability analysis of a Darrieus wind turbine

    NASA Astrophysics Data System (ADS)

    Popelka, D.

    1982-02-01

    An aeroelastic stability analysis was developed for predicting flutter instabilities on vertical axis wind turbines. The analytical model and mathematical formulation of the problem are described as well as the physical mechanism that creates flutter in Darrieus turbines. Theoretical results are compared with measured experimental data from flutter tests of the Sandia 2 Meter turbine. Based on this comparison, the analysis appears to be an adequate design evaluation tool.

  4. Aerothermoelastic Topology Optimization with Flutter and Buckling Metrics (Postprint)

    DTIC Science & Technology

    2013-07-01

    topologies of an unheated panel, thermal buckling-optimal topologies, and flutter- optimality of a heated panel (where the latter case presents a...topological compromise between the former two). The effect of various constraint boundaries, temperature gradients, and (for the flutter of the heated panel...optimality of a heated panel (where the latter case presents a topological compromise between the former two). The effect of various constraint boundaries

  5. Bending mode flutter in a transonic linear cascade

    NASA Astrophysics Data System (ADS)

    Govardhan, Raghuraman; Jutur, Prahallada

    2017-11-01

    Vibration related issues like flutter pose a serious challenge to aircraft engine designers. The phenomenon has gained relevance for modern engines that employ thin and long fan blade rows to satisfy the growing need for compact and powerful engines. The tip regions of such blade rows operate with transonic relative flow velocities, and are susceptible to bending mode flutter. In such cases, the flow field around individual blades of the cascade is dominated by shock motions generated by the blade motions. In the present work, a new transonic linear cascade facility with the ability to oscillate a blade at realistic reduced frequencies has been developed. The facility operates at a Mach number of 1.3, with the central blade being oscillated in heave corresponding to the bending mode of the rotor. The susceptibility of the blade to undergo flutter at different reduced frequencies is quantified by the cycle-averaged power transfer to the blade calculated using the measured unsteady load on the oscillating blade. These measurements show fluid excitation (flutter) at low reduced frequencies and fluid damping (no flutter) at higher reduced frequencies. Simultaneous measurements of the unsteady shock motions are done with high speed shadowgraphy to elucidate the differences in shock motions between the excitation and damping cases.

  6. Analytical and experimental investigation of flutter suppression by piezoelectric actuation

    NASA Technical Reports Server (NTRS)

    Heeg, Jennifer

    1993-01-01

    The objective of this research was to analytically and experimentally study the capabilities of piezoelectric plate actuators for suppressing flutter. Piezoelectric materials are characterized by their ability to produce voltage when subjected to a mechanical strain. The converse piezoelectric effect can be utilized to actuate a structure by applying a voltage. For this investigation, a two-degree-of-freedom wind tunnel model was designed, analyzed, and tested. The model consisted of a rigid wing and a flexible mount system that permitted a translational and a rotational degree of freedom. The model was designed such that flutter was encountered within the testing envelope of the wind tunnel. Actuators made of piezoelectric material were affixed to leaf springs of the mount system. Command signals, applied to the piezoelectric actuators, exerted control over the damping and stiffness properties. A mathematical aeroservoelastic model was constructed by using finite element methods, laminated plate theory, and aeroelastic analysis tools. Plant characteristics were determined from this model and verified by open loop experimental tests. A flutter suppression control law was designed and implemented on a digital control computer. Closed loop flutter testing was conducted. The experimental results represent the first time that adaptive materials have been used to actively suppress flutter. They demonstrate that small, carefully placed actuating plates can be used effectively to control aeroelastic response.

  7. Transonic Flutter Suppression Control Law Design, Analysis and Wind Tunnel Results

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1999-01-01

    The benchmark active controls technology and wind tunnel test program at NASA Langley Research Center was started with the objective to investigate the nonlinear, unsteady aerodynamics and active flutter suppression of wings in transonic flow. The paper will present the flutter suppression control law design process, numerical nonlinear simulation and wind tunnel test results for the NACA 0012 benchmark active control wing model. The flutter suppression control law design processes using (1) classical, (2) linear quadratic Gaussian (LQG), and (3) minimax techniques are described. A unified general formulation and solution for the LQG and minimax approaches, based on the steady state differential game theory is presented. Design considerations for improving the control law robustness and digital implementation are outlined. It was shown that simple control laws when properly designed based on physical principles, can suppress flutter with limited control power even in the presence of transonic shocks and flow separation. In wind tunnel tests in air and heavy gas medium, the closed-loop flutter dynamic pressure was increased to the tunnel upper limit of 200 psf The control law robustness and performance predictions were verified in highly nonlinear flow conditions, gain and phase perturbations, and spoiler deployment. A non-design plunge instability condition was also successfully suppressed.

  8. Transonic Flutter Suppression Control Law Design, Analysis and Wind-Tunnel Results

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1999-01-01

    The benchmark active controls technology and wind tunnel test program at NASA Langley Research Center was started with the objective to investigate the nonlinear, unsteady aerodynamics and active flutter suppression of wings in transonic flow. The paper will present the flutter suppression control law design process, numerical nonlinear simulation and wind tunnel test results for the NACA 0012 benchmark active control wing model. The flutter suppression control law design processes using (1) classical, (2) linear quadratic Gaussian (LQG), and (3) minimax techniques are described. A unified general formulation and solution for the LQG and minimax approaches, based on the steady state differential game theory is presented. Design considerations for improving the control law robustness and digital implementation are outlined. It was shown that simple control laws when properly designed based on physical principles, can suppress flutter with limited control power even in the presence of transonic shocks and flow separation. In wind tunnel tests in air and heavy gas medium, the closed-loop flutter dynamic pressure was increased to the tunnel upper limit of 200 psf. The control law robustness and performance predictions were verified in highly nonlinear flow conditions, gain and phase perturbations, and spoiler deployment. A non-design plunge instability condition was also successfully suppressed.

  9. Transonic Flutter Suppression Control Law Design Using Classical and Optimal Techniques with Wind-Tunnel Results

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, Vivek

    1999-01-01

    The benchmark active controls technology and wind tunnel test program at NASA Langley Research Center was started with the objective to investigate the nonlinear, unsteady aerodynamics and active flutter suppression of wings in transonic flow. The paper will present the flutter suppression control law design process, numerical nonlinear simulation and wind tunnel test results for the NACA 0012 benchmark active control wing model. The flutter suppression control law design processes using (1) classical, (2) linear quadratic Gaussian (LQG), and (3) minimax techniques are described. A unified general formulation and solution for the LQG and minimax approaches, based on the steady state differential game theory is presented. Design considerations for improving the control law robustness and digital implementation are outlined. It was shown that simple control laws when properly designed based on physical principles, can suppress flutter with limited control power even in the presence of transonic shocks and flow separation. In wind tunnel tests in air and heavy gas medium, the closed-loop flutter dynamic pressure was increased to the tunnel upper limit of 200 psf. The control law robustness and performance predictions were verified in highly nonlinear flow conditions, gain and phase perturbations, and spoiler deployment. A non-design plunge instability condition was also successfully suppressed.

  10. Extreme variation in the atrial septation of caecilians (Amphibia: Gymnophiona)

    PubMed Central

    de Bakker, Desiderius M; Wilkinson, Mark; Jensen, Bjarke

    2015-01-01

    Caecilians (order Gymnophiona) are elongate, limbless, snake-like amphibians that are the sister-group (closest relatives) of all other recent amphibians (frogs and salamanders). Little is known of their cardiovascular anatomy and physiology, but one nearly century old study suggests that Hypogeophis (family Indotyphlidae), commonly relied upon as a representative caecilian species, has atrial septation in the frontal plane and more than one septum. In contrast, in other vertebrates there generally is one atrial septum in the sagittal plane. We studied the adult heart of Idiocranium (also Indotyphlidae) using immunohistochemistry and confirm that the interatrial septum is close to the frontal plane. Additionally, a parallel right atrial septum divides three-fourths of the right atrial cavity of this species. Idiocranium embryos in the Hill collection reveal that atrial septation initiates in the sagittal plane as in other tetrapods. Late developmental stages, however, see a left-ward shift of visceral organs and a concordant rotation of the atria that reorients the atrial septa towards the frontal plane. The gross anatomies of species from six other caecilian families reveal that (i) the right atrial septum developed early in caecilian evolution (only absent in Rhinatrematidae) and that (ii) rotation of the atria evolved later and its degree varies between families. In most vertebrates a prominent atrial trabeculation associates with the sinuatrial valve, the so-called septum spurium, and the right atrial septum seems homologous to this trabeculation but much more developed. The right atrial septum does not appear to be a consequence of body elongation because it is absent in some caecilians and in snakes. The interatrial septum of caecilians shares multiple characters with the atrial septum of lungfishes, salamanders and the embryonic septum primum of amniotes. In conclusion, atrial septation in caecilians is based on evolutionarily conserved structures but possibly exhibits greater variation than in any other vertebrate order. PMID:25400089

  11. Heterogeneity of transverse-axial tubule system in mouse atria: Remodeling in atrial-specific Na+-Ca2+ exchanger knockout mice.

    PubMed

    Yue, Xin; Zhang, Rui; Kim, Brian; Ma, Aiqun; Philipson, Kenneth D; Goldhaber, Joshua I

    2017-07-01

    Transverse-axial tubules (TATs) are commonly assumed to be sparse or absent in atrial myocytes from small animals. Atrial myocytes from rats, cats and rabbits lack TATs, which results in a characteristic "V"-shaped Ca release pattern in confocal line-scan recordings due to the delayed rise of Ca in the center of the cell. To examine TAT expression in isolated mouse atrial myocytes, we loaded them with the membrane dye Di-4-ANEPPS to label TATs. We found that >80% of atrial myocytes had identifiable TATs. Atria from male mice had a higher TAT density than female mice, and TAT density correlated with cell width. Using the fluorescent Ca indicator Fluo-4-AM and confocal imaging, we found that wild type (WT) mouse atrial myocytes generate near-synchronous Ca transients, in contrast to the "V"-shaped pattern typically reported in other small animals such as rat. In atrial-specific Na-Ca exchanger (NCX) knockout (KO) mice, which develop sinus node dysfunction and atrial hypertrophy with dilation, we found a substantial loss of atrial TATs in isolated atrial myocytes. There was a greater loss of transverse tubules compared to axial tubules, resulting in a dominance of axial tubules. Consistent with the overall loss of TATs, NCX KO atrial myocytes displayed a "V"-shaped Ca transient with slower and reduced central (CT) Ca release and uptake in comparison to subsarcolemmal (SS) Ca release. We compared chemically detubulated (DT) WT cells to KO, and found similar slowing of CT Ca release and uptake. However, SS Ca transients in the WT DT cells had faster uptake kinetics than KO cells, consistent with the presence of NCX and normal sarcolemmal Ca efflux in the WT DT cells. We conclude that the remodeling of NCX KO atrial myocytes is accompanied by a loss of TATs leading to abnormal Ca release and uptake that could impact atrial contractility and rhythm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Spatially divergent cardiac responses to nicotinic stimulation of ganglionated plexus neurons in the canine heart.

    PubMed

    Cardinal, René; Pagé, Pierre; Vermeulen, Michel; Ardell, Jeffrey L; Armour, J Andrew

    2009-01-28

    Ganglionated plexuses (GPs) are major constituents of the intrinsic cardiac nervous system, the final common integrator of regional cardiac control. We hypothesized that nicotinic stimulation of individual GPs exerts divergent regional influences, affecting atrial as well as ventricular functions. In 22 anesthetized canines, unipolar electrograms were recorded from 127 atrial and 127 ventricular epicardial loci during nicotine injection (100 mcg in 0.1 ml) into either the 1) right atrial (RA), 2) dorsal atrial, 3) left atrial, 4) inferior vena cava-inferior left atrial, 5) right ventricular, 6) ventral septal ventricular or 7) cranial medial ventricular (CMV) GP. In addition to sinus and AV nodal function, neural effects on atrial and ventricular repolarization were identified as changes in the area subtended by unipolar recordings under basal conditions and at maximum neurally-induced effects. Animals were studied with intact AV node or following ablation to achieve ventricular rate control. Atrial rate was affected in response to stimulation of all 7 GPs with an incidence of 50-95% of the animals among the different GPs. AV conduction was affected following stimulation of 6/7 GP with an incidence of 22-75% among GPs. Atrial and ventricular repolarization properties were affected by atrial as well as ventricular GP stimulation. Distinct regional patterns of repolarization changes were identified in response to stimulation of individual GPs. RAGP predominantly affected the RA and posterior right ventricular walls whereas CMVGP elicited biatrial and biventricular repolarization changes. Spatially divergent and overlapping cardiac regions are affected in response to nicotinic stimulation of neurons in individual GPs.

  13. Percutaneous Occlusion of the Left Atrial Appendage with the Watchman Device in an Active Duty Sailor with Atrial Fibrillation and Recurrent Thromboembolism Despite Appropriate Use of Oral Anticoagulation.

    PubMed

    Cox, Justin M; Choi, Anthony J; Oakley, Luke S; Francisco, Gregory M; Nayak, Keshav R

    2018-05-23

    Atrial fibrillation is the most common significant cardiac arrhythmia and is associated with a five-fold increased risk of stroke from thromboembolism. Over 94% of these emboli arise from the left atrial appendage. Systemic embolic phenomena are rare, accounting for less than 1 out of 10 of all embolic events, but have a similar prevention strategy. Anticoagulation significantly reduces the risk of these events, and thus forms the cornerstone of therapy for most patients with atrial fibrillation. Left atrial appendage occlusion with the Watchman device is a recently approved alternative for stroke prevention in selected patients. We present a case of an active duty U.S. Navy sailor at low risk for thromboembolism who nonetheless suffered recurrent thromboembolic events despite appropriate anticoagulation, and thus underwent Watchman implantation. The therapy in this case will ideally provide a lifetime of protection from recurrent systemic embolization while allowing the patient to continue his active duty military career without restriction due to oral anticoagulation.

  14. Magnetic-flutter-induced pedestal plasma transport

    NASA Astrophysics Data System (ADS)

    Callen, J. D.; Hegna, C. C.; Cole, A. J.

    2013-11-01

    Plasma toroidal rotation can limit reconnection of externally applied resonant magnetic perturbation (RMP) fields δB on rational magnetic flux surfaces. Hence it causes the induced radial perturbations δBρ to be small there, thereby inhibiting magnetic island formation and stochasticity at the top of pedestals in high (H-mode) confinement tokamak plasmas. However, the δBρs induced by RMPs increase away from rational surfaces and are shown to induce significant sinusoidal radial motion (flutter) of magnetic field lines with a radial extent that varies linearly with δBρ and inversely with distance from the rational surface because of the magnetic shear. This produces a radial electron thermal diffusivity that is (1/2)(δBρ/B0)2 times a kinetically derived, electron-collision-induced, magnetic-shear-reduced, effective parallel electron thermal diffusivity in the absence of magnetic stochasticity. These low collisionality flutter-induced transport processes and thin magnetic island effects are shown to be highly peaked in the vicinity of rational surfaces at the top of low collisionality pedestals. However, the smaller but finite level of magnetic-flutter-induced electron heat transport midway between rational surfaces is the primary factor that determines the electron temperature difference between rational surfaces at the pedestal top. The magnetic-flutter-induced non-ambipolar electron density transport can be large enough to push the plasma toward an electron density transport root. Requiring ambipolar density transport is shown to determine the radial electric field, the plasma toroidal rotation (via radial force balance), a reduced electron thermal diffusivity and increased ambipolar density transport in the pedestal. At high collisionality the various flutter effects are less strongly peaked at rational surfaces and generally less significant. They are thus less likely to exhibit flutter-induced resonant behaviour and transition toward an electron transport root. Magnetic-flutter-induced plasma transport processes provide a new paradigm for developing an understanding of how RMPs modify the pedestal structure to stabilize peeling-ballooning modes and thereby suppress edge localized modes in low collisionality tokamak H-mode plasmas.

  15. Proposed aeroelastic and flutter tests for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Stevenson, J. R.

    1981-01-01

    Tests that can exploit the capability of the NTF and the transonic cryogenic tunnel, or lead to improvements that could enhance testing in the NTF are discussed. Shock induced oscillation, supersonic single degree control surface flutter, and transonic flutter speed as a function of the Reynolds number are considered. Honeycombs versus screens to smooth the tunnel flow and a rapid tunnel dynamic pressure reducer are recommended to improve tunnel performance.

  16. Status and future plans of the Drones for Aerodynamic and Structural Testing (DAST) program. [Aeroelastic Research Wing (ARW)

    NASA Technical Reports Server (NTRS)

    Murrow, H. N.

    1981-01-01

    Results from flight tests of the ARW-1 research wing are presented. Preliminary loads data and experiences with the active control system for flutter suppression are included along with comparative results of test and prediction for the flutter boundary of the supercritical research wing and on performance of the flutter suppression system. The status of the ARW-2 research wing is given.

  17. Application of the unsteady vortex-lattice method to the nonlinear two-degree-of-freedom aeroelastic equations

    NASA Technical Reports Server (NTRS)

    Strganac, T. W.; Mook, D. T.

    1986-01-01

    A means of numerically simulating flutter is established by implementing a predictor-corrector algorithm to solve the equations of motion. Aerodynamic loads are provided by the unsteady vortex lattice method (UVLM). This method is illustrated via the obtainment of stable and unstable responses to initial disturbances in the case of two-degree-of-freedom motion. It was found that for some angles of attack and dynamic pressure, the initial disturbance decays, for others it grows (flutter). When flutter occurs, the solution yields the amplitude and period of the resulting limit cycle. The preliminaray results attest to the feasibility of this method for studying flutter in cases that would be difficult to treat using a classical approach.

  18. Control of forward swept wing configurations dominated by flight-dynamic/aeroelastic interactions

    NASA Technical Reports Server (NTRS)

    Rimer, M.; Chipman, R.; Muniz, B.

    1984-01-01

    An active control system concept for an aeroelastic wind-tunnel model of a statically unstable FSW configuration with wing-mounted stores is developed to provide acceptable longitudinal flying qualities while maintaining adequate flutter speed margin. On FSW configurations, the inherent aeroelastic wing divergence tendency causes strong flight-dynamic/aeroelastic interactions that in certain cases can produce a dynamic instability known as body-freedom flutter (BFF). The carriage of wing-mounted stores is shown to severely aggravate this problem. The control system developed combines a canard-based SAS with an Active Divergence/Flutter Suppression (ADFS) system which relies on wing-mounted sensors and a trailing-edge device (flaperon). Synergism between these two systems is exploited to obtain the flying qualities and flutter speed objectives.

  19. Tilt-rotor flutter control in cruise flight

    NASA Technical Reports Server (NTRS)

    Nasu, Ken-Ichi

    1986-01-01

    Tilt-rotor flutter control under cruising operation is analyzed. The rotor model consists of a straight fixed wing, a pylon attached to the wingtip, and a three-blade rotor. The wing is cantilevered to the fuselage and is allowed to bend forward and upward. It also has a torsional degree of freedom about the elastic axis. Each rotor blade has two bending degrees of freedom. Feedback of wingtip velocity and acceleration to cyclic pitch is investigated for flutter control, using strip theory and linearized equations of motion. To determine the feedback gain, an eigenvalue analysis is performed. A second, independent, timewise calculation is conducted to evaluate the control law while employing more sophisticated aerodynamics. The effectiveness of flutter control by cyclic pitch change was confirmed.

  20. Wind tunnel tests of main girder with Π-shaped cross section

    NASA Astrophysics Data System (ADS)

    Guo, Junfeng; Hong, Chengjing; Zheng, Shixiong; Zhu, Jinbo

    2017-10-01

    The wind-resistant performance of a cable stayed bridge with IT-shaped girder was investigated by means of wind tunnel tests. Aerodynamic coefficients experiments and wind-induced vibration experiments with a sectional model a geometry scale of l to 60 were conducted. The results have shown that this kind of girder has the necessary condition for aerodynamic stability. Soft flutter of the main girder is a coupled two-degree-of-freedom torsional-bending vibration with single frequency. The amplitude of soft flutter follows a normal distribution, and the amplitude range varies with wind speed and angle of attack. The bridge deck auxiliary facilities can not only improve the critical soft flutter velocity, but also reduce the soft flutter amplitude and the amplitude growth rate.

  1. Experimental transonic steady state and unsteady pressure measurements on a supercritical wing during flutter and forced discrete frequency oscillations

    NASA Technical Reports Server (NTRS)

    Piette, Douglas S.; Cazier, Frank W., Jr.

    1989-01-01

    Present flutter analysis methods do not accurately predict the flutter speeds in the transonic flow region for wings with supercritical airfoils. Aerodynamic programs using computational fluid dynamic (CFD) methods are being developed, but these programs need to be verified before they can be used with confidence. A wind tunnel test was performed to obtain all types of data necessary for correlating with CFD programs to validate them for use on high aspect ratio wings. The data include steady state and unsteady aerodynamic measurements on a nominal stiffness wing and a wing four times that stiffness. There is data during forced oscillations and during flutter at several angles of attack, Mach numbers, and tunnel densities.

  2. Comparison of analysis and flight test data for a drone aircraft with active flutter suppression

    NASA Technical Reports Server (NTRS)

    Newsom, J. R.; Pototzky, A. S.

    1981-01-01

    A drone aircraft equipped with an active flutter suppression system is considered with emphasis on the comparison of modal dampings and frequencies as a function of Mach number. Results are presented for both symmetric and antisymmetric motion with flutter suppression off. Only symmetric results are given for flutter suppression on. Frequency response functions of the vehicle are presented from both flight test data and analysis. The analysis correlation is improved by using an empirical aerodynamic correction factor which is proportional to the ratio of experimental to analytical steady-state lift curve slope. The mathematical models are included and existing analytical techniques are described as well as an alternative analytical technique for obtaining closed-loop results.

  3. Unusual presentation of total anomalous systemic venous connection.

    PubMed

    Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Pradhan, Priya M; Agarwal, Ravi

    2017-07-01

    A 9-year-old girl who presented with dyspnea on exertion was diagnosed with total anomalous systemic venous connection to the left atrium (both venae cavae), no left superior vena cava, and a moderate-sized atrial septal defect with severe pulmonary arterial hypertension and ectopic atrial rhythm. She underwent septation of the common atrium using autologous pericardium, thereby rerouting the superior vena cava, inferior vena cava, and coronary sinus to the right atrium. Her postoperative course was uneventful. This case is reported for its rarity of presentation with severe pulmonary arterial hypertension and ectopic atrial rhythm.

  4. [Splenic infarction after warfarin discontinuation during atrial fibrillation].

    PubMed

    Trappolini, M; Scorzai, A; Loguercio, V; Stoppo, M; Sebastianelli, A; Iannotta, M; Del Porto, F; Proietta, M; Aliberti, G

    2008-01-01

    We describe a case of patient with splenic infarction, admitted to our department for sudden abdominal pain and fever after discontinuation of anticoagulant therapy for atrial fibrillation, complicating a dilated myocardiopathy and mechanical prosthetic valve. Diagnosis of splenic infarction was made by enhanced-contrast computed tomography, while ultrasounds and radiography were negative. Anticoagulant therapy, gold-standard treatment, was followed by fast clinical improvement. Moreover, splenic infarction should be considered in all cases of acute or chronic pain in left hypochondrium and especially in patients with emboligenous cardiopathies or atrial fibrillation, the most common arrhythmia source of peripheral embolism in clinical practice.

  5. Computationally efficient method for localizing the spiral rotor source using synthetic intracardiac electrograms during atrial fibrillation.

    PubMed

    Shariat, M H; Gazor, S; Redfearn, D

    2015-08-01

    Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, is an extremely costly public health problem. Catheter-based ablation is a common minimally invasive procedure to treat AF. Contemporary mapping methods are highly dependent on the accuracy of anatomic localization of rotor sources within the atria. In this paper, using simulated atrial intracardiac electrograms (IEGMs) during AF, we propose a computationally efficient method for localizing the tip of the electrical rotor with an Archimedean/arithmetic spiral wavefront. The proposed method deploys the locations of electrodes of a catheter and their IEGMs activation times to estimate the unknown parameters of the spiral wavefront including its tip location. The proposed method is able to localize the spiral as soon as the wave hits three electrodes of the catheter. Our simulation results show that the method can efficiently localize the spiral wavefront that rotates either clockwise or counterclockwise.

  6. Aneurysm of the Left Atrial Appendage

    PubMed Central

    Victor, Solomon; Nayak, Vijaya M.

    2001-01-01

    A 43-year-old woman underwent excision of an aneurysm of the left atrial appendage, which had been causing cerebrovascular embolic episodes. We attribute the aneurysm to congenital dysplasia of the musculi pectinati in the left atrial appendage and of the bands of atrial muscle from which they arise. In Appendix I, we draw attention to the morphologically similar arrangements of inner and outer bands that emanate from a common transverse interatrial band and yield morphologically similar medial, descending, and ascending palm-leaf arrangements of musculi pectinati. In addition, we observe that the strap-like arrangements of musculi in both atria connect the outer band with the para-annular segment of the inner band. In Appendix II, we briefly review the literature concerning musculi pectinati and related bands. PMID:11453121

  7. Trends in hospitalization for atrial fibrillation: epidemiology, cost, and implications for the future.

    PubMed

    Sheikh, Azfar; Patel, Nileshkumar J; Nalluri, Nikhil; Agnihotri, Kanishk; Spagnola, Jonathan; Patel, Aashay; Asti, Deepak; Kanotra, Ritesh; Khan, Hafiz; Savani, Chirag; Arora, Shilpkumar; Patel, Nilay; Thakkar, Badal; Patel, Neil; Pau, Dhaval; Badheka, Apurva O; Deshmukh, Abhishek; Kowalski, Marcin; Viles-Gonzalez, Juan; Paydak, Hakan

    2015-01-01

    Atrial fibrillation (AF) is the most prevalent arrhythmia worldwide and the most common arrhythmia leading to hospitalization. Due to a substantial increase in incidence and prevalence of AF over the past few decades, it attributes to an extensive economic and public health burden. The increasing number of hospitalizations, aging population, anticoagulation management, and increasing trend for disposition to a skilled facility are drivers of the increasing cost associated with AF. There has been significant progress in AF management with the release of new oral anticoagulants, use of left atrial catheter ablation, and novel techniques for left atrial appendage closure. In this article, we aim to review the trends in epidemiology, hospitalization, and cost of AF along with its future implications on public health. Published by Elsevier Inc.

  8. Untreated atrial fibrillation in the United States of America: Understanding the barriers and treatment options

    PubMed Central

    Verdino, Ralph J.

    2014-01-01

    Atrial fibrillation is the most commonly treated arrhythmia in the United States of America. Stroke is the most devastating consequence of atrial fibrillation. For decades, warfarin has been the most recommended treatment for patients with atrial fibrillation at risk for stroke and systemic emboli. However, many patients at risk are not treated with anticoagulants. Several reasons exist, including physician underestimation of patient stroke risk, physician overestimation of bleeding risk, and patients’ reluctance to take chronic warfarin due to the difficulties of this medication in relation to its pharmacokinetics and interactions with food and other medications. Risk scores have helped to better define patient risks and benefits from chronic anticoagulation. Novel anticoagulants (NOACs) have improved the ability for patients to be compliant with anticoagulation. PMID:25561824

  9. Genome-wide screening identifies a KCNIP1 copy number variant as a genetic predictor for atrial fibrillation

    PubMed Central

    Tsai, Chia-Ti; Hsieh, Chia-Shan; Chang, Sheng-Nan; Chuang, Eric Y.; Ueng, Kwo-Chang; Tsai, Chin-Feng; Lin, Tsung-Hsien; Wu, Cho-Kai; Lee, Jen-Kuang; Lin, Lian-Yu; Wang, Yi-Chih; Yu, Chih-Chieh; Lai, Ling-Ping; Tseng, Chuen-Den; Hwang, Juey-Jen; Chiang, Fu-Tien; Lin, Jiunn-Lee

    2016-01-01

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. Previous genome-wide association studies had identified single-nucleotide polymorphisms in several genomic regions to be associated with AF. In human genome, copy number variations (CNVs) are known to contribute to disease susceptibility. Using a genome-wide multistage approach to identify AF susceptibility CNVs, we here show a common 4,470-bp diallelic CNV in the first intron of potassium interacting channel 1 gene (KCNIP1) is strongly associated with AF in Taiwanese populations (odds ratio=2.27 for insertion allele; P=6.23 × 10−24). KCNIP1 insertion is associated with higher KCNIP1 mRNA expression. KCNIP1-encoded protein potassium interacting channel 1 (KCHIP1) is physically associated with potassium Kv channels and modulates atrial transient outward current in cardiac myocytes. Overexpression of KCNIP1 results in inducible AF in zebrafish. In conclusions, a common CNV in KCNIP1 gene is a genetic predictor of AF risk possibly pointing to a functional pathway. PMID:26831368

  10. Molecular Mechanisms and New Treatment Paradigm for Atrial Fibrillation.

    PubMed

    Sirish, Padmini; Li, Ning; Timofeyev, Valeriy; Zhang, Xiao-Dong; Wang, Lianguo; Yang, Jun; Lee, Kin Sing Stephen; Bettaieb, Ahmed; Ma, Sin Mei; Lee, Jeong Han; Su, Demetria; Lau, Victor C; Myers, Richard E; Lieu, Deborah K; López, Javier E; Young, J Nilas; Yamoah, Ebenezer N; Haj, Fawaz; Ripplinger, Crystal M; Hammock, Bruce D; Chiamvimonvat, Nipavan

    2016-05-01

    Atrial fibrillation represents the most common arrhythmia leading to increased morbidity and mortality, yet, current treatment strategies have proven inadequate. Conventional treatment with antiarrhythmic drugs carries a high risk for proarrhythmias. The soluble epoxide hydrolase enzyme catalyzes the hydrolysis of anti-inflammatory epoxy fatty acids, including epoxyeicosatrienoic acids from arachidonic acid to the corresponding proinflammatory diols. Therefore, the goal of the study is to directly test the hypotheses that inhibition of the soluble epoxide hydrolase enzyme can result in an increase in the levels of epoxyeicosatrienoic acids, leading to the attenuation of atrial structural and electric remodeling and the prevention of atrial fibrillation. For the first time, we report findings that inhibition of soluble epoxide hydrolase reduces inflammation, oxidative stress, atrial structural, and electric remodeling. Treatment with soluble epoxide hydrolase inhibitor significantly reduces the activation of key inflammatory signaling molecules, including the transcription factor nuclear factor κ-light-chain-enhancer, mitogen-activated protein kinase, and transforming growth factor-β. This study provides insights into the underlying molecular mechanisms leading to atrial fibrillation by inflammation and represents a paradigm shift from conventional antiarrhythmic drugs, which block downstream events to a novel upstream therapeutic target by counteracting the inflammatory processes in atrial fibrillation. © 2016 American Heart Association, Inc.

  11. Increased expression of NF-AT3 and NF-AT4 in the atria correlates with procollagen I carboxyl terminal peptide and TGF-β1 levels in serum of patients with atrial fibrillation.

    PubMed

    Zhao, Fei; Zhang, ShiJiang; Chen, YiJiang; Gu, WeiDong; Ni, BuQing; Shao, YongFeng; Wu, YanHu; Qin, JianWei

    2014-11-25

    Atrial fibrillation (AF) is the most common cardiac arrhythmia in clinical practice. Unfortunately, the precise mechanisms and sensitive serum biomarkers of atrial remodeling in AF remain unclear. The aim of this study was to determine whether the expression of the transcription factors NF-AT3 and NF-AT4 correlate with atrial structural remodeling of atrial fibrillation and serum markers for collagen I and III synthesis. Right and left atrial specimens were obtained from 90 patients undergoing valve replacement surgery. The patients were divided into sinus rhythm (n = 30), paroxysmal atrial fibrillation (n = 30), and persistent atrial fibrillation (n = 30) groups. NF-AT3, NF-AT4, and collagen I and III mRNA and protein expression in atria were measured. We also tested the levels of the carboxyl-terminal peptide from pro-collagen I, the N-terminal type I procollagen propeptides, the N-terminal type III procollagen propeptides, and TGF-β1 in serum using an enzyme immunosorbent assay. NF-AT3 and NF-AT4 mRNA and protein expression were increased in the AF groups, especially in the left atrium. NF-AT3 and NF-AT4 expression in the right atrium was increased in the persistent atrial fibrillation group compared the sinus rhythm group with similar valvular disease. In patients with AF, the expression levels of nuclear NF-AT3 and NF-AT4 correlated with those of collagens I and III in the atria and with PICP and TGF-β1 in blood. These data support the hypothesis that nuclear NF-AT3 and NF-AT4 participates in atrial structural remodeling, and that PICP and TGF-β1 levels may be sensitive serum biomarkers to estimate atrial structural remodeling with atrial fibrillation.

  12. Does preoperative atrial fibrillation influence early and late outcomes of coronary artery bypass grafting?

    PubMed

    Ngaage, Dumbor L; Schaff, Hartzell V; Mullany, Charles J; Sundt, Thoralf M; Dearani, Joseph A; Barnes, Sunni; Daly, Richard C; Orszulak, Thomas A

    2007-01-01

    The study objective was to describe the independent effect of preoperative atrial fibrillation on the outcome of coronary artery bypass grafting, including the causes of death (cardiac vs noncardiac). We analyzed the outcome of patients with preoperative atrial fibrillation who underwent on-pump coronary artery bypass grafting between 1993 and 2002 and compared them with matched controls in sinus rhythm; matching variables were age, gender, ejection fraction, and numbers of diseased coronary arteries and distal anastomoses. Direct patient follow-up focused on late complications and reinterventions, and we investigated causes for all deaths. Operative mortality (1.6% vs 1.9%, P = .79) was similar in patients with preoperative atrial fibrillation (n = 257) compared with patients in sinus rhythm (n = 269). The patients with atrial fibrillation had longer hospital stays (9 +/- 6 days vs 8 +/- 6 days, P = .0008) and a trend to more frequent early readmissions (13% vs 9%, P = .08). During follow-up (median 6.7 years, maximum 12 years), late hospital admission was more frequent in patients with atrial fibrillation (59% vs 31%, P < .0001). Risk of late mortality (all causes) in patients with atrial fibrillation was increased by 40% compared with patients in sinus rhythm (P = 0.02), and the late cardiac death rate in the atrial fibrillation group was 2.8 times that of the sinus rhythm group (P = .0004). Major adverse cardiac events occurred in 70% of patients with preoperative atrial fibrillation compared with 52% of patients in preoperative sinus rhythm (P < .0001). Subsequent rhythm-related intervention, including pacemaker implantations, was more common in the atrial fibrillation group (relative risk = 2.1, P = .0027). Uncorrected preoperative atrial fibrillation in patients undergoing coronary artery bypass grafting is associated with increased late cardiac morbidity and mortality and poor long-term survival. These data support consideration of atrial fibrillation surgery at the time of coronary artery bypass grafting.

  13. Effectiveness, safety and costs of thromboembolic prevention in patients with non-valvular atrial fibrillation: phase I ESC-FA protocol study and baseline characteristics of a cohort from a primary care electronic database

    PubMed Central

    Vedia Urgell, Cristina; Roso-Llorach, Albert; Morros, Rosa; Capellà, Dolors; Castells, Xavier; Ferreira-González, Ignacio; Troncoso Mariño, Amelia; Diògene, Eduard; Elorza, Josep Mª; Casajuana, Marc; Bolíbar, Bonaventura; Violan, Concepció

    2016-01-01

    Purpose Atrial fibrillation is the most common arrhythmia. Its management aims to reduce symptoms and to prevent complications through rate and rhythm control, management of concomitant cardiac diseases and prevention of related complications, mainly stroke. The main objective of Effectiveness, Safety and Costs in Atrial Fibrillation (ESC-FA) study is to analyse the drugs used for the management of the disease in real-use conditions, particularly the antithrombotic agents for stroke prevention. The aim of this work is to present the study protocol of phase I of the ESC-FA study and the baseline characteristics of newly diagnosed patients with atrial fibrillation in Catalonia, Spain. Participants The data source is System for the Improvement of Research in Primary Care (SIDIAP) database. The population included are all patients with non-valvular atrial fibrillation diagnosis registered in the electronic health records during 2007–2012. Findings to date A total of 22 585 patients with non-valvular atrial fibrillation were included in the baseline description. Their mean age was 72.8 years and 51.6% were men. The most commonly prescribed antithrombotics were vitamin K antagonists (40.1% of patients) and platelet aggregation inhibitors (32.9%); 25.3% had not been prescribed antithrombotic treatment. Age, gender, comorbidities and co-medication at baseline were similar to those reported for previous studies. Future plans The next phase in the ESC-FA study will involve assessing the effectiveness and safety of antithrombotic treatments, analysing stroke events and bleeding episodes’ rates in our patients (rest of phase I), describing the current management of the disease and its costs in our setting, and assessing how the introduction of new oral anticoagulants changes the stroke prevention in non-valvular atrial fibrillation. PMID:26823179

  14. Reduced Uncertainties in the Flutter Analysis of the Aerostructures Test Wing

    NASA Technical Reports Server (NTRS)

    Pak, Chan-gi; Lung, Shun-fat

    2010-01-01

    Tuning the finite element model using measured data to minimize the model uncertainties is a challenging task in the area of structural dynamics. A test validated finite element model can provide a reliable flutter analysis to define the flutter placard speed to which the aircraft can be flown prior to flight flutter testing. Minimizing the difference between numerical and experimental results is a type of optimization problem. Through the use of the National Aeronautics and Space Administration Dryden Flight Research Center s (Edwards, California, USA) multidisciplinary design, analysis, and optimization tool to optimize the objective function and constraints; the mass properties, the natural frequencies, and the mode shapes are matched to the target data and the mass matrix orthogonality is retained. The approach in this study has been applied to minimize the model uncertainties for the structural dynamic model of the aerostructures test wing, which was designed, built, and tested at the National Aeronautics and Space Administration Dryden Flight Research Center. A 25-percent change in flutter speed has been shown after reducing the uncertainties

  15. Experimental unsteady pressures at flutter on the Supercritical Wing Benchmark Model

    NASA Technical Reports Server (NTRS)

    Dansberry, Bryan E.; Durham, Michael H.; Bennett, Robert M.; Rivera, Jose A.; Silva, Walter A.; Wieseman, Carol D.; Turnock, David L.

    1993-01-01

    This paper describes selected results from the flutter testing of the Supercritical Wing (SW) model. This model is a rigid semispan wing having a rectangular planform and a supercritical airfoil shape. The model was flutter tested in the Langley Transonic Dynamics Tunnel (TDT) as part of the Benchmark Models Program, a multi-year wind tunnel activity currently being conducted by the Structural Dynamics Division of NASA Langley Research Center. The primary objective of this program is to assist in the development and evaluation of aeroelastic computational fluid dynamics codes. The SW is the second of a series of three similar models which are designed to be flutter tested in the TDT on a flexible mount known as the Pitch and Plunge Apparatus. Data sets acquired with these models, including simultaneous unsteady surface pressures and model response data, are meant to be used for correlation with analytical codes. Presented in this report are experimental flutter boundaries and corresponding steady and unsteady pressure distribution data acquired over two model chords located at the 60 and 95 percent span stations.

  16. An overview of selected NASP aeroelastic studies at the NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Spain, Charles V.; Soistmann, David L.; Parker, Ellen C.; Gibbons, Michael D.; Gilbert, Michael G.

    1990-01-01

    Following an initial discussion of the NASP flight environment, the results of recent aeroelastic testing of NASP-type highly swept delta-wing models in Langley's Transonic Dynamics Tunnel (TDT) are summarized. Subsonic and transonic flutter characteristics of a variety of these models are described, and several analytical codes used to predict flutter of these models are evaluated. These codes generally provide good, but conservative predictions of subsonic and transonic flutter. Also, test results are presented on a nonlinear transonic phenomena known as aileron buzz which occurred in the wind tunnel on highly swept delta wings with full-span ailerons. An analytical procedure which assesses the effects of hypersonic heating on aeroelastic instabilities (aerothermoelasticity) is also described. This procedure accurately predicted flutter of a heated aluminum wing on which experimental data exists. Results are presented on the application of this method to calculate the flutter characteristics of a fine-element model of a generic NASP configuration. Finally, it is demonstrated analytically that active controls can be employed to improve the aeroelastic stability and ride quality of a generic NASP vehicle flying at hypersonic speeds.

  17. Reduced Uncertainties in the Flutter Analysis of the Aerostructures Test Wing

    NASA Technical Reports Server (NTRS)

    Pak, Chan-Gi; Lung, Shun Fat

    2011-01-01

    Tuning the finite element model using measured data to minimize the model uncertainties is a challenging task in the area of structural dynamics. A test validated finite element model can provide a reliable flutter analysis to define the flutter placard speed to which the aircraft can be flown prior to flight flutter testing. Minimizing the difference between numerical and experimental results is a type of optimization problem. Through the use of the National Aeronautics and Space Administration Dryden Flight Research Center's (Edwards, California) multidisciplinary design, analysis, and optimization tool to optimize the objective function and constraints; the mass properties, the natural frequencies, and the mode shapes are matched to the target data, and the mass matrix orthogonality is retained. The approach in this study has been applied to minimize the model uncertainties for the structural dynamic model of the aerostructures test wing, which was designed, built, and tested at the National Aeronautics and Space Administration Dryden Flight Research Center. A 25 percent change in flutter speed has been shown after reducing the uncertainties.

  18. Critical and post-critical behaviour of two-degree-of-freedom flutter-based generators

    NASA Astrophysics Data System (ADS)

    Pigolotti, Luca; Mannini, Claudio; Bartoli, Gianni; Thiele, Klaus

    2017-09-01

    Energy harvesting from flow-induced vibrations is a recent research field, which considers a diverse range of systems, among which two-degree-of-freedom flutter-based solutions were individuated as good candidates to obtain high energy performance. In the present work, numerical linear analyses and wind-tunnel tests were conducted on a flat-plate sectional model. The aim is to identify some design guidelines for generators exploiting the classical-flutter instability, through the investigation of the critical condition and the response during the post-critical regime. Many sets of governing parameters of interest from the energy-harvesting point of view were considered, including high levels of heaving damping to simulate the operation of a conversion apparatus. In particular, eccentricity of the elastic centre and small downstream mass unbalance can be introduced as solutions aiming at optimal operative ranges. The collected results suggest the high potentiality of flutter-based generators, and a significant enhancement of performance can be envisaged. Moreover, they contribute to improve the knowledge of the flutter excitation mechanism and to widen the dataset of measurements in the post-critical regime.

  19. Variable use of amiodarone is associated with a greater risk of recurrence of atrial fibrillation in the critically ill.

    PubMed

    Mitrić, Goran; Udy, Andrew; Bandeshe, Hiran; Clement, Pierre; Boots, Rob

    2016-04-02

    Atrial fibrillation is a common rhythm disturbance in the general medical-surgical intensive care unit. Amiodarone is a popular drug in this setting but evidence to inform clinical practice remains scarce. We aimed to identify whether variation in the clinical use of amiodarone was associated with recurrent atrial fibrillation. This was a retrospective audit of 177 critically ill patients who developed new-onset atrial fibrillation after admission to a tertiary level medical-surgical trauma intensive care unit. Patterns of amiodarone prescription (including dosage schedule and duration) were assessed in relation to recurrence of atrial fibrillation during the intensive care unit stay. Known recurrence risk factors, such as inotrope administration, cardiac disease indices, Charlson Comorbidity Index, magnesium concentrations, fluid balance, and potassium concentrations, were also included in adjusted analysis using forward stepwise logistic regression modelling. The cohort had a median (interquartile range) age of 69 years (60-75), Acute Physiology and Chronic Health Evalution II score of 22 (17-28) and Charlson Comorbidity Index of 2 (1-4). A bolus dose of amiodarone followed by infusion (P = 0.02), in addition to continuing amiodarone infusion through to discharge from the intensive care unit (P < 0.001), were associated with less recurrent dysrhythmia. Recurrence after successful treatment was associated with ceasing amiodarone while an inotrope infusion continued (P < 0.001), and was more common in patients with a prior history of congestive cardiac failure (P = 0.04), and a diagnosis of systemic inflammatory response syndrome (P = 0.02). Amiodarone should be administered as a bolus dose followed immediately with an infusion when treating atrial fibrillation in the medical-surgical intensive care unit. Consideration should be given to continuing amiodarone infusions in patients on inotropes until they are ceased.

  20. Atrial isomerism: a surgical experience.

    PubMed

    Sinzobahamvya, N; Arenz, C; Brecher, A M; Urban, A E

    1999-06-01

    Most publications on atrial isomerism are autopsy or case reports. The authors review 41 consecutive children operated on from 1980 through to 1996 with emphasis on associated cardiac anomalies, surgical procedures and outcome. Left atrial isomerism was present in 23 patients. Interruption of the inferior vena cava (56%), atrio-ventricular septal defect (47%), common atrium (38%) and cor triatriatum sinistrum (30%) were the most common diagnoses. Biventricular repair was achieved in 17 children and total cavo-pulmonary connection in two. Three underwent staged palliation: modified Blalock-Taussig shunt for two and bidirectional Glenn anastomosis for one. The remainder received a cardiac pacemaker. One patient died early after repair. Two underwent reoperation to correct a regurgitant left atrio-ventricular valve: one of these, in another hospital, had peroperative death. Three died later. Actuarial survival rate after repair and total cavo-pulmonary connection that was stabilized after 2 years was 84%. In the 18 children with right atrial isomerism, pulmonary atresia or stenosis predominated (89%) with discordant ventriculo-arterial connection (72%), atrio-ventricular septal defect (72%), 'single' ventricle (55%) and extracardiac total anomalous pulmonary venous drainage (50%). Biventricular repair was achieved in two patients and complete Fontan circulation in eight. The other eight underwent various staged palliative procedures and correction of extracardiac total anomalous pulmonary venous drainage. Five patients died postoperatively: two in our unit after modified Blalock-Taussig shunt and total cavo-pulmonary connection, three in other hospitals after repair (n = 1) and Fontan (n = 2). Five died later. One was lost for review. Survival after repair and Fontan stabilized after 6 months at 49%. In conclusion, the cardiovascular malformations associated with left atrial isomerism can often be successfully corrected. Those accompanying right atrial isomerism usually preclude a biventricular repair, require staged palliation and carry a poor prognosis.

Top